Design of inductive sensors for tongue control system for computers and assistive devices.
Lontis, Eugen R; Struijk, Lotte N S A
2010-07-01
The paper introduces a novel design of air-core inductive sensors in printed circuit board (PCB) technology for a tongue control system. The tongue control system provides a quadriplegic person with a keyboard and a joystick type of mouse for interaction with a computer or for control of an assistive device. Activation of inductive sensors was performed with a cylindrical, soft ferromagnetic material (activation unit). Comparative analysis of inductive sensors in PCB technology with existing hand-made inductive sensors was performed with respect to inductance, resistance, and sensitivity to activation when the activation unit was placed in the center of the sensor. Optimisation of the activation unit was performed in a finite element model. PCBs with air-core inductive sensors were manufactured in a 10 layers, 100 microm and 120 microm line width technology. These sensors provided quality signals that could drive the electronics of the hand-made sensors. Furthermore, changing the geometry of the sensors allowed generation of variable signals correlated with the 2D movement of the activation unit at the sensors' surface. PCB technology for inductive sensors allows flexibility in design, automation of production and ease of possible integration with supplying electronics. The basic switch function of the inductive sensor can be extended to two-dimensional movement detection for pointing devices.
Design of Low Inductance Switching Power Cell for GaN HEMT Based Inverter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gurpinar, Emre; Iannuzzo, Francesco; Yang, Yongheng
Here in this paper, an ultra-low inductance power cell is designed for a three-Level Active Neutral Point Clamped (3LANPC) based on 650 V gallium nitride (GaN) HEMT devices. The 3L-ANPC topology with GaN HEMT devices and the selected modulation scheme suitable for wide-bandgap (WBG) devices are presented. The commutation loops, which mainly contribute to voltage overshoots and increase of switching losses, are discussed. The ultra-low inductance power cell design based on a fourlayer Printed Circuit Board (PCB) with the aim to maximize the switching performance of GaN HEMTs is explained. The design of gate drivers for the GaN HEMT devicesmore » is presented. Parasitic inductance and resistance of the proposed design are extracted with finite element analysis and discussed. Common mode behaviours based on the SPICE model of the converter are analyzed. Experimental results on the designed 3L-ANPC with the output power of up to 1 kW are presented, which verifies the performance of the proposed design in terms of ultra-low inductance.« less
Electrothermal feedback in kinetic inductance detectors
NASA Astrophysics Data System (ADS)
Guruswamy, T.; Thomas, C. N.; Withington, S.; Goldie, D. J.
2017-06-01
In kinetic inductance detectors (KIDs) and other similar applications of superconducting microresonators, both the large and small-signal behaviour of the device may be affected by electrothermal feedback. Microwave power applied to read out the device is absorbed by and heats the superconductor quasiparticles, changing the superconductor conductivity and hence the readout power absorbed in a positive or negative feedback loop. In this work, we explore numerically the implications of an extensible theoretical model of a generic superconducting microresonator device for a typical KID, incorporating recent work on the power flow between superconductor quasiparticles and phonons. This model calculates the large-signal (changes in operating point) and small-signal behaviour of a device, allowing us to determine the effect of electrothermal feedback on device responsivity and noise characteristics under various operating conditions. We also investigate how thermally isolating the device from the bath, for example by designing the device on a membrane only connected to the bulk substrate by thin legs, affects device performance. We find that at a typical device operating point, positive electrothermal feedback reduces the effective thermal conductance from the superconductor quasiparticles to the bath, and so increases responsivity to signal (pair-breaking) power, increases noise from temperature fluctuations, and decreases the noise equivalent power (NEP). Similarly, increasing the thermal isolation of the device while keeping the quasiparticle temperature constant decreases the NEP, but also decreases the device response bandwidth.
Electromagnetic Remote Sensing. Low Frequency Electromagnetics
1989-01-01
biased superconducting point - contact quantum devices", J.Appl.Phys. 41, p.1572, 1970. [40] A.Yariv and H.Winsor, "Proposal for detection of magnetic ... magnetics , electromagnetic induc- tion, electrostatics) 2. Nondestructive testing (electromagnetic induction, neutron tomography, x-ray imaging) 3...Detection of submarines from aircraft or ships ( magnetics , electromagnetic induction) 4. Detection of land vehicles using buried sensors ( magnetics
The Physics of Tokamak Start-up
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. Mueller
Tokamak start-up on present-day devices usually relies on inductively induced voltage from a central solenoid. In some cases inductive startup is assisted with auxiliary power from electron cyclotron radio frequency heating. ITER, the National Spherical Torus eXperiment Upgrade and JT60, now under construction, will make use of the understanding gained from present-day devices to ensure successful start-up. Design of a spherical tokamak (ST) with DT capability for nuclear component testing would require an alternative to a central solenoid because the small central column in an ST has insufficient space to provide shielding for the insulators in the solenoid. Alternative start-upmore » techniques such as induction using outer poloidal field coils, electron Bernstein wave start-up, coaxial helicity injection and point source helicity injection have been used with success, but require demonstration of scaling to higher plasma current.« less
The physics of tokamak start-up
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mueller, D.
Tokamak start-up on present-day devices usually relies on inductively induced voltage from a central solenoid. In some cases, inductive startup is assisted with auxiliary power from electron cyclotron radio frequency heating. International Thermonuclear Experimental Reactor, the National Spherical Torus Experiment Upgrade and JT60, now under construction, will make use of the understanding gained from present-day devices to ensure successful start-up. Design of a spherical tokamak (ST) with DT capability for nuclear component testing would require an alternative to a central solenoid because the small central column in an ST has insufficient space to provide shielding for the insulators in themore » solenoid. Alternative start-up techniques such as induction using outer poloidal field coils, electron Bernstein wave start-up, coaxial helicity injection, and point source helicity injection have been used with success, but require demonstration of scaling to higher plasma current.« less
Fast-acting self-healing metallic fuse.
NASA Technical Reports Server (NTRS)
Schwartz, F. C.; Renton, C. A.; Rabinovici, B.
1971-01-01
Description of a fast-acting nonmechanical self-healing mercury fuse capable of protecting a high current circuit or device from overcurrent fault damages. Basically the self-healing fuse consists of two enclosed mercury reservoirs connected by a fine capillary tube filled with mercury that serves as the fusing element. It is pointed out that a better understanding of the energy conversion process involved in the operation of the device could help explore other device configurations (such as a tapering geometry and use of magnetic field to drive the arc into the fuse wall on inductive loads, etc.) and thus extend the range of capabilities for this type of protective device.
Identification and validation of nebulized aerosol devices for sputum induction
Davidson, Warren J; Dennis, John; The, Stephanie; Litoski, Belinda; Pieron, Cora; Leigh, Richard
2014-01-01
Induced sputum cell count measurement has proven reliability for evaluating airway inflammation in patients with asthma and other airway diseases. Although the use of nebulizer devices for sputum induction is commonplace, they are generally labelled as single-patient devices by the manufacturer and, therefore, cannot be used for multiple patients in large clinical sputum induction programs due to infect ion-control requirements. Accordingly, this study investigated the aerosol characteristics of alternative devices that could be used in such programs. BACKGROUND: Induced sputum cell counts are a noninvasive and reliable method for evaluating the presence, type and degree of airway inflammation in patients with asthma. Currently, standard nebulizer devices used for sputum induction in multiple patients are labelled as single-patient devices by the manufacturer, which conflicts with infection prevention and control requirements. As such, these devices cannot feasibly be used in a clinical sputum induction program. Therefore, there is a need to identify alternative nebulizer devices that are either disposable or labelled for multi-patient use. OBJECTIVE: To apply validated rigorous, scientific testing methods to identify and validate commercially available nebulizer devices appropriate for use in a clinical sputum induction program. METHODS: Measurement of nebulized aerosol output and size for the selected nebulizer designs followed robust International Organization for Standardization methods. Sputum induction using two of these nebulizers was successfully performed on 10 healthy adult subjects. The cytotechnologist performing sputum cell counts was blinded to the type of nebulizer used. RESULTS: The studied nebulizers had variable aerosol outputs. The AeroNeb Solo (Aerogen, Ireland), Omron NE-U17 (Omron, Japan) and EASYneb II (Flaem Nuova, Italy) systems were found to have similar measurements of aerosol size. There was no significant difference in induced sputum cell results between the AeroNeb Solo and EASYneb II devices. DISCUSSION: There is a need for rigorous, scientific evaluation of nebulizer devices for clinical applications, including sputum induction, for measurement of cell counts. CONCLUSION: The present study was the most comprehensive analysis of different nebulizer devices for sputum induction to measure cell counts, and provides a framework for appropriate evaluation of nebulizer devices for induced sputum testing. PMID:24288700
The 23 to 300 C demagnetization resistance of samarium-cobalt permanent magnets
NASA Technical Reports Server (NTRS)
Niedra, Janis M.; Overton, Eric
1991-01-01
The influence of temperature on knee point and squareness of the M-H demagnetization characteristic of permanent magnets is important information for the full utilization of the capabilities of samarium-cobalt magnets at high temperature in demagnetization resistent permanent magnet devices. Composite plots of the knee field and the demagnetizing field required to produce a given magnetic induction swing below remanence were obtained for several commercial Sm2Co17 type magnet samples in the temperature range of 23 to 300 C. Using the knee point to define the limits of operation safe against irreversible demagnetization, such plots are shown to provide an effective overview of the useable regions in the space of temperature-induction swing parameters. The observed second quadrant M-H characteristic squareness is shown, by two measures, to increase gradually with temperature, reaching a peak in the interval 200 to 300 C.
Validation of a low-cost EEG device for mood induction studies.
Rodríguez, Alejandro; Rey, Beatriz; Alcañiz, Mariano
2013-01-01
New electroencephalography (EEG) devices, more portable and cheaper, are appearing on the market. Studying the reliability of these EEG devices for emotional studies would be interesting, as these devices could be more economical and compatible with Virtual Reality (VR) settings. Therefore, the aim in this work was to validate a low-cost EEG device (Emotiv Epoc) to monitor brain activity during a positive emotional induction procedure. Emotional pictures (IAPS) were used to induce a positive mood in sixteen participants. Changes in the brain activity of subjects were compared between positive induction and neutral conditions. Obtained results were in accordance with previous scientific literature regarding frontal EEG asymmetry, which supports the possibility of using this low-cost EEG device in future mood induction studies combined with VR.
Inherently safe passive gas monitoring system
Cordaro, Joseph V.; Bellamy, John Stephen; Shuler, James M.; Shull, Davis J.; Leduc, Daniel R.
2016-09-06
Generally, the present disclosure is directed to gas monitoring systems that use inductive power transfer to safely power an electrically passive device included within a nuclear material storage container. In particular, the electrically passive device can include an inductive power receiver for receiving inductive power transfer through a wall of the nuclear material storage container. The power received by the inductive power receiver can be used to power one or more sensors included in the device. Thus, the device is not required to include active power generation components such as, for example, a battery, that increase the risk of a spark igniting flammable gases within the container.
Electromagnetic Compatibility of Devices on Hybrid Electromagnetic Components
NASA Astrophysics Data System (ADS)
Konesev, S. G.; Khazieva, R. T.; Kirillov, R. V.; Gainutdinov, I. Z.; Kondratyev, E. Y.
2018-01-01
There is a general tendency to reduce the weight and dimensions, the consumption of conductive and electrical insulating materials, increase the reliability and energy efficiency of electrical devices. In recent years, designers have been actively developing devices based on hybrid electromagnetic components (HEMC) such as inductive-capacitive converters (ICC), voltages pulse generators (VPG), secondary power supplies (SPS), capacitive storage devices (CSD), induction heating systems (IHS). Sources of power supplies of similar electrical devices contain, as a rule, links of increased frequency and function in key (pulse) modes, which leads to an increase in electromagnetic interference (EMI). Nonlinear and periodic (impulse) loads, non-sinusoidal (pulsation) of the electromotive force and nonlinearity of the internal parameters of the source and input circuits of consumers distort the shape of the input voltage lead to an increase in thermal losses from the higher harmonic currents, aging of the insulation, increase in the weight of the power supply filter units, resonance at higher harmonics. The most important task is to analyze the operation of electrotechnical devices based on HEMC from the point of view of creating EMIs and assessing their electromagnetic compatibility (EMC) with power supply systems (PSS). The article presents the results of research on the operation of an IHS, the operation principle of a secondary power supply source of which is based on the operation of a half-bridge autonomous inverter, the switching circuit of which is made in the form of a HEMC, called the «multifunctional integrated electromagnetic component»" (MIEC).
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCarrick, H., E-mail: hlm2124@columbia.edu; Flanigan, D.; Jones, G.
We discuss the design, fabrication, and testing of prototype horn-coupled, lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic microwave background studies. The LEKIDs are made from a thin aluminum film deposited on a silicon wafer and patterned using standard photolithographic techniques at STAR Cryoelectronics, a commercial device foundry. We fabricated 20-element arrays, optimized for a spectral band centered on 150 GHz, to test the sensitivity and yield of the devices as well as the multiplexing scheme. We characterized the detectors in two configurations. First, the detectors were tested in a dark environment with the horn apertures covered, and second, themore » horn apertures were pointed towards a beam-filling cryogenic blackbody load. These tests show that the multiplexing scheme is robust and scalable, the yield across multiple LEKID arrays is 91%, and the measured noise-equivalent temperatures for a 4 K optical load are in the range 26±6 μK√(s)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Falferi, P.; Mezzena, R.; Vitale, S.
1997-08-01
The coupling effects of a commercial dc superconducting quantum interference device (SQUID) to an electrical LC resonator which operates at audio frequencies ({approx}1kHz) with quality factors Q{approx}10{sup 6} are presented. The variations of the resonance frequency of the resonator as functions of the flux applied to the SQUID are due to the SQUID dynamic inductance in good agreement with the predictions of a model. The variations of the quality factor point to a feedback mechanism between the output of the SQUID and the input circuit. {copyright} {ital 1997 American Institute of Physics.}
Coherent inductive communications link for biomedical applications
NASA Technical Reports Server (NTRS)
Hogrefe, Arthur F. (Inventor); Radford, Wade E. (Inventor)
1985-01-01
A two-way coherent inductive communications link between an external transceiver and an internal transceiver located in a biologically implanted programmable medical device. Digitally formatted command data and programming data is transmitted to the implanted medical device by frequency shift keying the inductive communications link. Internal transceiver is powered by the inductive field between internal and external transceivers. Digitally formatted data is transmitted to external transceiver by internal transceiver amplitude modulating inductive field. Immediate verification of the establishment of a reliable communications link is provided by determining existence of frequency lock and bit phase lock between internal and external transceivers.
Modeling of a Stacked Power Module for Parasitic Inductance Extraction
2017-09-15
issues of heat dissipation, reliability, and parasitic inductance. An improved packaging approach has been proposed to simultaneously address each of...and mechanical attachments. The power devices in the resulting module design are stacked between copper layers with an integrated heat sink. By...stacking devices, the module’s parasitic inductance should be reduced, with concurrent improvement of reliability and heat dissipation, in comparison to
Gaseous detonation initiation via wave implosion
NASA Astrophysics Data System (ADS)
Jackson, Scott Irving
Efficient detonation initiation is a topic of intense interest to designers of pulse detonation engines. This experimental work is the first to detonate propane-air mixtures with an imploding detonation wave and to detonate a gas mixture with a non-reflected, imploding shock. In order to do this, a unique device has been developed that is capable of generating an imploding toroidal detonation wave inside of a tube from a single ignition point without any obstruction to the tube flow path. As part of this study, an initiator that creates a large-aspect-ratio planar detonation wave in gas-phase explosive from a single ignition point has also been developed. The effectiveness of our initiation devices has been evaluated. The minimum energy required by the imploding shock for initiation was determined to scale linearly with the induction zone length, indicating the presence of a planar initiation mode. The imploding toroidal detonation initiator was found to be more effective at detonation initiation than the imploding shock initiator, using a comparable energy input to that of current initiator tubes.
Physics of Tokamak Plasma Start-up
NASA Astrophysics Data System (ADS)
Mueller, Dennis
2012-10-01
This tutorial describes and reviews the state-of-art in tokamak plasma start-up and its importance to next step devices such as ITER, a Fusion Nuclear Science Facility and a Tokamak/ST demo. Tokamak plasma start-up includes breakdown of the initial gas, ramp-up of the plasma current to its final value and the control of plasma parameters during those phases. Tokamaks rely on an inductive component, typically a central solenoid, which has enabled attainment of high performance levels that has enabled the construction of the ITER device. Optimizing the inductive start-up phase continues to be an area of active research, especially in regards to achieving ITER scenarios. A new generation of superconducting tokamaks, EAST and KSTAR, experiments on DIII-D and operation with JET's ITER-like wall are contributing towards this effort. Inductive start-up relies on transformer action to generate a toroidal loop voltage and successful start-up is determined by gas breakdown, avalanche physics and plasma-wall interaction. The goal of achieving steady-sate tokamak operation has motivated interest in other methods for start-up that do not rely on the central solenoid. These include Coaxial Helicity Injection, outer poloidal field coil start-up, and point source helicity injection, which have achieved 200, 150 and 100 kA respectively of toroidal current on closed flux surfaces. Other methods including merging reconnection startup and Electron Bernstein Wave (EBW) plasma start-up are being studied on various devices. EBW start-up generates a directed electron channel due to wave particle interaction physics while the other methods mentioned rely on magnetic helicity injection and magnetic reconnection which are being modeled and understood using NIMROD code simulations.
A static induction device manufactured by silicon direct bonding
NASA Astrophysics Data System (ADS)
Chen, Xin'an; Liu, Su; Huang, Qing'an
2004-07-01
It is always a key problem how to improve the gate-source breakdown voltage (VGK) of static induction devices during manufacturing. By using a silicon direct bonding process to replace the high resistivity epitaxy process, a bonding buried gate structure is formed, which is different from an epitaxy buried gate structure. The new structure can improve the gate-source breakdown voltage from the process and the structure. It is shown that the bonding buried gate structure is a promising structure, that can improve the VGK and other performances of devices, by manufacture of a static induction thyristor.
Development of induction current acquisition device based on ARM
NASA Astrophysics Data System (ADS)
Ji, Yanju; Liu, Xiyang; Huang, Wanyu; Yao, Jiang; Yuan, Guiyang; Hui, Luan; Guan, Shanshan
2018-03-01
We design an induction current acquisition device based on ARM in order to realize high resolution and high sampling rate of acquisition for the induction current in wire-loop. Considering its characteristics of fast attenuation and small signal amplitude, we use the method of multi-path fusion for noise suppression. In the paper, the design is carried out from three aspects of analog circuit and device selection, independent power supply structure and the electromagnetic interference suppression of high frequency. DMA and ping-pong buffer, as a new data transmission technology, solves real time storage problem of massive data. The performance parameters of ARM acquisition device are tested. The comparison test of ARM acquisition device and cRIO acquisition device is performed at different time constants. The results show that it has 120dB dynamic range, 47kHz bandwidth, 96kHz sampling rate, 5μV the smallest resolution, and its average error value is not more than 4%, which proves the high accuracy and stability of the device.
Skeist, S. Merrill; Baker, Richard H.
2005-10-11
An electro-mechanical energy conversion system coupled between an energy source and an energy load including an energy converter device having a doubly fed induction machine coupled between the energy source and the energy load to convert the energy from the energy source and to transfer the converted energy to the energy load and an energy transfer multiplexer coupled to the energy converter device to control the flow of power or energy through the doubly fed induction machine.
Mythical thinking, scientific discourses and research dissemination.
Hroar Klempe, Sven
2011-06-01
This article focuses on some principles for understanding. By taking Anna Mikulak's article "Mismatches between 'scientific' and 'non-scientific' ways of knowing and their contributions to public understanding of science" (IPBS 2011) as a point of departure, the idea of demarcation criteria for scientific and non-scientific discourses is addressed. Yet this is juxtaposed with mythical thinking, which is supposed to be the most salient trait of non-scientific discourses. The author demonstrates how the most widespread demarcation criterion, the criterion of verification, is self-contradictory, not only when it comes to logic, but also in the achievement of isolating natural sciences from other forms of knowledge. According to Aristotle induction is a rhetorical device and as far as scientific statements are based on inductive inferences, they are relying on humanities, which rhetoric is a part of. Yet induction also has an empirical component by being based on sense-impressions, which is not a part of the rhetoric, but the psychology. Also the myths are understood in a rhetorical (Lévi-Strauss) and a psychological (Cassirer) perspective. Thus it is argued that both scientific and non-scientific discourses can be mythical.
Low pressure EGR system having full range capability
Easley, Jr., William Lanier; Milam, David Michael; Roozenboom, Stephan Donald; Bond, Michael Steven; Kapic, Amir
2009-09-22
An exhaust treatment system for an engine is disclosed and may have an air induction circuit, an exhaust circuit, and an exhaust recirculation circuit. The air induction circuit may be configured to direct air into the engine. The exhaust circuit may be configured to direct exhaust from the engine and include a turbine driven by the exhaust, a particulate filter disposed in series with and downstream of the turbine, and a catalytic device disposed in series with and downstream of the particulate filter. The exhaust recirculation circuit may be configured to selectively redirect at least some of the exhaust from between the particulate filter and the catalytic device to the air induction circuit. The catalytic device is selected to create backpressure within the exhaust circuit sufficient to ensure that, under normal engine operating conditions above low idle, exhaust can flow into the air induction circuit without throttling of the air.
40 CFR 63.10898 - What are my performance test requirements?
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (3) If you have an electric induction furnace equipped with an emissions control device at an existing foundry, you may use the test results from another electric induction furnace to demonstrate... induction furnace at an existing foundry, you may use the test results from another electric induction...
40 CFR 63.10898 - What are my performance test requirements?
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (3) If you have an electric induction furnace equipped with an emissions control device at an existing foundry, you may use the test results from another electric induction furnace to demonstrate... induction furnace at an existing foundry, you may use the test results from another electric induction...
40 CFR 63.10898 - What are my performance test requirements?
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (3) If you have an electric induction furnace equipped with an emissions control device at an existing foundry, you may use the test results from another electric induction furnace to demonstrate... induction furnace at an existing foundry, you may use the test results from another electric induction...
40 CFR 63.10898 - What are my performance test requirements?
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (3) If you have an electric induction furnace equipped with an emissions control device at an existing foundry, you may use the test results from another electric induction furnace to demonstrate... induction furnace at an existing foundry, you may use the test results from another electric induction...
40 CFR 63.10898 - What are my performance test requirements?
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (3) If you have an electric induction furnace equipped with an emissions control device at an existing foundry, you may use the test results from another electric induction furnace to demonstrate... induction furnace at an existing foundry, you may use the test results from another electric induction...
Inductance analysis of superconducting quantum interference devices with 3D nano-bridge junctions
NASA Astrophysics Data System (ADS)
Wang, Hao; Yang, Ruoting; Li, Guanqun; Wu, Long; Liu, Xiaoyu; Chen, Lei; Ren, Jie; Wang, Zhen
2018-05-01
Superconducting quantum interference devices (SQUIDs) with 3D nano-bridge junctions can be miniaturized into nano-SQUIDs that are able to sense a few spins in a large magnetic field. Among all device parameters, the inductance is key to the performance of SQUIDs with 3D nano-bridge junctions. Here, we measured the critical-current magnetic flux modulation curves of 12 devices with three design types using a current strip-line directly coupled to the SQUID loop. A best flux modulation depth of 71% was achieved for our 3D Nb SQUID. From the modulation curves, we extracted the inductance values of the current stripe-line in each design and compared them with the corresponding simulation results of InductEX. In this way, London penetration depths of 110 and 420 nm were determined for our Nb (niobium) and NbN (niobium nitride) films, respectively. Furthermore, we showed that inductances of 11 and 119 pH for Nb and NbN 3D nano-bridge junctions, respectively, dominated the total inductance of our SQUID loops which are 23 pH for Nb and 255 pH for NbN. A screening parameter being equal to one suggests optimal critical currents of 89.6 and 8.1 μA for Nb and NbN SQUIDs, respectively. Additionally, intrinsic flux noise of 110 ± 40 nΦ0/(Hz)1/2 is calculated for the Nb SQUIDs with 3D nano-bridge junctions by Langevin simulation.
Inductively heated shape memory polymer for the magnetic actuation of medical devices.
Buckley, Patrick R; McKinley, Gareth H; Wilson, Thomas S; Small, Ward; Benett, William J; Bearinger, Jane P; McElfresh, Michael W; Maitland, Duncan J
2006-10-01
Presently, there is interest in making medical devices such as expandable stents and intravascular microactuators from shape memory polymer (SMP). One of the key challenges in realizing SMP medical devices is the implementation of a safe and effective method of thermally actuating various device geometries in vivo. A novel scheme of actuation by Curie-thermoregulated inductive heating is presented. Prototype medical devices made from SMP loaded with nickel zinc ferrite ferromagnetic particles were actuated in air by applying an alternating magnetic field to induce heating. Dynamic mechanical thermal analysis was performed on both the particle-loaded and neat SMP materials to assess the impact of the ferrite particles on the mechanical properties of the samples. Calorimetry was used to quantify the rate of heat generation as a function of particle size and volumetric loading of ferrite particles in the SMP. These tests demonstrated the feasibility of SMP actuation by inductive heating. Rapid and uniform heating was achieved in complex device geometries and particle loading up to 10% volume content did not interfere with the shape recovery of the SMP.
NASA Astrophysics Data System (ADS)
Igarashi, Hironobu; Sato, Takashi; Miyamoto, Kazunori; Kurokawa, Kousuke
The photovoltaic generation system must have protection device and islanding detection devices to connect with utility line of the electric power company. It is regulated in the technological requirement guideline and the electric equipment technology standard that the country provides. The islanding detection device detected purpose install for blackout due to the accident occurrence of the earth fault and the short-circuit in the utility line. When the islanding detection device detects the power blackout, it is necessary to stop the photovoltaic generation system immediately. If the photovoltaic generation system is not stopped immediately, electricity comes to charge the utility power line very at risk. We had already known that the islanding detection device can't detect the islanding phenomenon, if is there the induction motor in the loads. Authors decided to investigate the influence that the induction motors gave to the islanding detection device. The result was the load condition that the induction motors changed generator the voltage is restraining. Moreover, it was clarified that the time of the islanding was long compared with the load condition of not changing into the state of the generator. The value changes into the reactance of the induction motors according to the frequency change after the supply of electric power line stops. The frequency after the supply of electric power line stops changes for the unbalance the reactive power by the effect of the power rate constancy control with PLL of the power conditioner. However, the induction motors is also to the changing frequency, makes amends for the amount of reactive power, and the change in the frequency after the supply of electric power line stops as a result is controlled. When the frequency changed after the supply of electric power line stopped, it was clarified of the action on the direction where it made amends from the change of the constant for the amount of an invalid electric power, and the possession of the characteristic in which the continuance of the individual operation was promoted.
ERIC Educational Resources Information Center
Alterovitz, Gil
2004-01-01
This research analyzed both engineering and nontechnical issues involved in the use of Induction Loop Amplification (ILA) devices in auditoriums or large gathering places for hard-of-hearing individuals. A variety of parameters need to be taken into account to determine an optimal shape/configuration for the ILA device. In many cases, an optimal…
Flywheel induction motor-generator for magnet power supply in small fusion device.
Hatakeyma, S; Yoshino, F; Tsutsui, H; Tsuji-Iio, S
2016-04-01
A flywheel motor-generator (MG) for the toroidal field (TF) coils of a small fusion device was developed which utilizes a commercially available squirrel-cage induction motor. Advantages of the MG are comparably-long duration, quick power response, and easy implementation of power control compared with conventional capacitor-type power supply. A 55-kW MG was fabricated, and TF coils of a small fusion device were energized. The duration of the current flat-top was extended to 1 s which is much longer than those of conventional small devices (around 10-100 ms).
Flywheel induction motor-generator for magnet power supply in small fusion device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hatakeyma, S., E-mail: hatakeyama.shoichi@torus.nr.titech.ac.jp; Yoshino, F.; Tsutsui, H.
2016-04-15
A flywheel motor-generator (MG) for the toroidal field (TF) coils of a small fusion device was developed which utilizes a commercially available squirrel-cage induction motor. Advantages of the MG are comparably-long duration, quick power response, and easy implementation of power control compared with conventional capacitor-type power supply. A 55-kW MG was fabricated, and TF coils of a small fusion device were energized. The duration of the current flat-top was extended to 1 s which is much longer than those of conventional small devices (around 10–100 ms).
The endpoint detection technique for deep submicrometer plasma etching
NASA Astrophysics Data System (ADS)
Wang, Wei; Du, Zhi-yun; Zeng, Yong; Lan, Zhong-went
2009-07-01
The availability of reliable optical sensor technology provides opportunities to better characterize and control plasma etching processes in real time, they could play a important role in endpoint detection, fault diagnostics and processes feedback control and so on. The optical emission spectroscopy (OES) method becomes deficient in the case of deep submicrometer gate etching. In the newly developed high density inductively coupled plasma (HD-ICP) etching system, Interferometry endpoint (IEP) is introduced to get the EPD. The IEP fringe count algorithm is investigated to predict the end point, and then its signal is used to control etching rate and to call end point with OES signal in over etching (OE) processes step. The experiment results show that IEP together with OES provide extra process control margin for advanced device with thinner gate oxide.
Bulmer, John; Bullard, Thomas; Dolasinski, Brian; Murphy, John; Sparkes, Martin; Pangovski, Krste; O’Neill, William; Powers, Peter; Haugan, Timothy
2015-01-01
An electromagnetic transmitter typically consists of individual components such as a waveguide, antenna, power supply, and an oscillator. In this communication we circumvent complications associated with connecting these individual components and instead combine them into a non-traditional, photonic enabled, compact transmitter device for tunable, ultrawide band (UWB) radiation. This device is a centimeter scale, continuous, thin film superconducting ring supporting a persistent super-current. An ultrafast laser pulse (required) illuminates the ring (either at a point or uniformly around the ring) and perturbs the super-current by the de-pairing and recombination of Cooper pairs. This generates a microwave pulse where both ring and laser pulse geometry dictates the radiated spectrum’s shape. The transmitting device is self contained and completely isolated from conductive components that are observed to interfere with the generated signal. A rich spectrum is observed that extends beyond 30 GHz (equipment limited) and illustrates the complex super-current dynamics bridging optical, THz, and microwave wavelengths. PMID:26659022
Microwave Switching and Attenuation with Superconductors.
NASA Astrophysics Data System (ADS)
Poulin, Grant Darcy
1995-01-01
The discovery of high temperature superconducting (HTS) materials having a critical temperature above the boiling point of liquid nitrogen has generated a large amount of interest in both the basic and applied scientific communities. Considerable research effort has been expended in developing HTS microwave devices, since thin film, passive, microwave components will likely be the first area to be successfully commercialized. This thesis describes a new thin film HTS microwave device that can be operated as a switch or as a continuously variable attenuator. It is well suited for low power analog signal control applications and can easily be integrated with other HTS devices. Due to its small size and mass, the device is expected to find application as a receiver protection switch or as an automatic gain control element, both used in satellite communications receivers. The device has a very low insertion loss, and the isolation in the OFF state is continuously variable to 25 dB. With minor modifications, an isolation exceeding 50 dB is readily achievable. A patent application for the device has been filed, with the patent rights assigned to COM DEV. The device is based on an unusual non-linear response in HTS materials. Under a non-zero DC voltage bias, the current through a superconducting bridge is essentially voltage independent. We have proposed a thermal instability to account for this behaviour. Thermal modelling in conjunction with direct temperature measurements were used to confirm the validity of the model. We have developed a detailed model explaining the microwave response of the device. The model accurately predicts the microwave attenuation as a function of the applied DC control voltage and fully explains the device operation. A key feature is that the device acts as a pure resistive element at microwave frequencies, with no reactance. The resistance is continuously variable, controlled by the DC bias voltage. This distinguishes it from a PIN diode, since PIN diodes have a capacitive reactance that limits their frequency range. Measurements made to confirm the microwave model validity resulted in the development of a new cryogenic de-embedding technique. The technique allows accurate microwave measurements to be made on devices at cryogenic temperatures using only room temperature calibration standards. We have also investigated the effect of kinetic inductance on coplanar waveguide transmission lines, and indicate under what conditions kinetic inductance must be considered in transmission line design.
Wireless power transfer electric vehicle supply equipment installation and validation tool
Jones, Perry T.; Miller, John M.
2015-05-19
A transmit pad inspection device includes a magnetic coupling device, which includes an inductive circuit that is configured to magnetically couple to a primary circuit of a charging device in a transmit pad through an alternating current (AC) magnetic field. The inductive circuit functions as a secondary circuit for a set of magnetically coupled coils. The magnetic coupling device further includes a rectification circuit, and includes a controllable load bank or is configured to be connected to an external controllable load back. The transmit pad inspection device is configured to determine the efficiency of power transfer under various coupling conditions. In addition, the transmit pad inspection device can be configured to measure residual magnetic field and the frequency of the input current, and to determine whether the charging device has been installed properly.
Method and device for determining bond separation strength using induction heating
NASA Technical Reports Server (NTRS)
Coultrip, Robert H. (Inventor); Johnson, Samuel D. (Inventor); Copeland, Carl E. (Inventor); Phillips, W. Morris (Inventor); Fox, Robert L. (Inventor)
1994-01-01
An induction heating device includes an induction heating gun which includes a housing, a U-shaped pole piece having two spaced apart opposite ends defining a gap there between, the U-shaped pole piece being mounted in one end of the housing, and a tank circuit including an induction coil wrapped around the pole piece and a capacitor connected to the induction coil. A power source is connected to the tank circuit. A pull test machine is provided having a stationary chuck and a movable chuck, the two chucks holding two test pieces bonded together at a bond region. The heating gun is mounted on the pull test machine in close proximity to the bond region of the two test pieces, whereby when the tank circuit is energized, the two test pieces are heated by induction heating while a tension load is applied to the two test pieces by the pull test machine to determine separation strength of the bond region.
Plasma Source Development for LAPD
NASA Astrophysics Data System (ADS)
Pribyl, P.; Gekelman, W.; Drandell, M.; Grunspen, S.; Nakamoto, M.; McBarron, A.
2003-10-01
The Large Plasma Device (LAPD) relies on an indirectly heated Barium Oxide (BaO) cathode to generate an extremely repeatable low-noise plasma. However there are two defects of this system: one is that the cathode is subject to oxygen poisoning in the event of accidental air leaks, requiring a lengthy recoating and regeneration process. Second, the indirect radiative heating is only about 50 % efficient, leading to a series of reliability issues. Alternate plasma sources are being investigated, including two types of directly heated BaO cathode and several configurations of inductively coupled RF plasmas. Direct heating for a cathode can be achieved either by embedding heaters within the nickel substrate, or by using inductive heating techniques to drive currents within the nickel itself. In both cases, the BaO coating still serves to emit the electrons and thus generate the plasma arc. An improved system would generate the plasma without the use of a "cathode" e.g. by inductively coupling energy directly into the plasma discharge. This technique is being investigated from the point of view of whether a) the bulk of the plasma column can be made sufficiently low-noise to be of experimental value and b) sufficiently dense plasmas can be formed.
Development of very small-diameter, inductively coupled magnetized plasma device
NASA Astrophysics Data System (ADS)
Kuwahara, D.; Mishio, A.; Nakagawa, T.; Shinohara, S.
2013-10-01
In order to miniaturize a high-density, inductively coupled magnetized plasma or helicon plasma to be applied to, e.g., an industrial application and an electric propulsion field, small helicon device has been developed. The specifications of this device along with the experimental results are described. We have succeeded in generating high-density (˜1019 m-3) plasmas using quartz tubes with very small diameters of 10 and 20 mm, with a radio frequency power ˜1200 and 700 W, respectively, in the presence of the magnetic field less than 1 kG.
Development of very small-diameter, inductively coupled magnetized plasma device.
Kuwahara, D; Mishio, A; Nakagawa, T; Shinohara, S
2013-10-01
In order to miniaturize a high-density, inductively coupled magnetized plasma or helicon plasma to be applied to, e.g., an industrial application and an electric propulsion field, small helicon device has been developed. The specifications of this device along with the experimental results are described. We have succeeded in generating high-density (~10(19) m(-3)) plasmas using quartz tubes with very small diameters of 10 and 20 mm, with a radio frequency power ~1200 and 700 W, respectively, in the presence of the magnetic field less than 1 kG.
Joseph, Karunan; Ibrahim, Fatimah; Cho, Jongman; Thio, Tzer Hwai Gilbert; Al-Faqheri, Wisam; Madou, Marc
2015-01-01
The development of micro-power generators for centrifugal microfluidic discs enhances the platform as a green point-of-care diagnostic system and eliminates the need for attaching external peripherals to the disc. In this work, we present micro-power generators that harvest energy from the disc's rotational movement to power biomedical applications on the disc. To implement these ideas, we developed two types of micro-power generators using piezoelectric films and an electromagnetic induction system. The piezoelectric-based generator takes advantage of the film's vibration during the disc's rotational motion, whereas the electromagnetic induction-based generator operates on the principle of current generation in stacks of coil exposed to varying magnetic flux. We have successfully demonstrated that at the spinning speed of 800 revolutions per minute (RPM) the piezoelectric film-based generator is able to produce up to 24 microwatts using 6 sets of films and the magnetic induction-based generator is capable of producing up to 125 milliwatts using 6 stacks of coil. As a proof of concept, a custom made localized heating system was constructed to test the capability of the magnetic induction-based generator. The heating system was able to achieve a temperature of 58.62 °C at 2200 RPM. This development of lab-on-a-disc micro power generators preserves the portability standards and enhances the future biomedical applications of centrifugal microfluidic platforms.
Wirelessly powered microfluidic dielectrophoresis devices using printable RF circuits.
Qiao, Wen; Cho, Gyoujin; Lo, Yu-Hwa
2011-03-21
We report the first microfluidic device integrated with a printed RF circuit so the device can be wirelessly powered by a commercially available RFID reader. For conventional dielectrophoresis devices, electrical wires are needed to connect the electric components on the microchip to external equipment such as power supplies, amplifiers, function generators, etc. Such a procedure is unfamiliar to most clinicians and pathologists who are used to working with a microscope for examination of samples on microscope slides. The wirelessly powered device reported here eliminates the entire need for wire attachments and external instruments so the operators can use the device in essentially the same manner as they do with microscope slides. The integrated circuit can be fabricated on a flexible plastic substrate at very low cost using a roll-to-roll printing method. Electrical power at 13.56 MHz transmitted by a radio-frequency identification (RFID) reader is inductively coupled to the printed RFIC and converted into 10 V DC (direct current) output, which provides sufficient power to drive a microfluidic device to manipulate biological particles such as beads and proteins via the DC dielectrophoresis (DC-DEP) effect. To our best knowledge, this is the first wirelessly powered microfluidic dielectrophoresis device. Although the work is preliminary, the device concept, the architecture, and the core technology are expected to stimulate many efforts in the future and transform the technology to a wide range of clinical and point-of-care applications. This journal is © The Royal Society of Chemistry 2011
NASA Astrophysics Data System (ADS)
Che, George
The inductance of a conductor expresses its tendency to oppose a change in current flowing through it. For superconductors, in addition to the familiar magnetic inductance due to energy stored in the magnetic field generated by this current, kinetic inductance due to inertia of charge carriers is a significant and often dominant contribution to total inductance. Devices based on modifying the kinetic inductance of thin film superconductors have widespread application to millimeter-wave astronomy. Lithographically patterning such a film into a high quality factor resonator produces a high sensitivity photodetector known as a kinetic inductance detector (KID), which is sensitive to frequencies above the superconducting energy gap of the chosen material. Inherently multiplexable in the frequency domain and relatively simple to fabricate, KIDs pave the way to the large format focal plane array instruments necessary to conduct the next generation of cosmic microwave background (CMB), star formation, and galaxy evolution studies. In addition, non-linear kinetic inductance can be exploited to develop traveling wave kinetic inductance parametric amplifiers (TKIPs) based on superconducting delay lines to read out these instruments. I present my contributions to both large and small scale collaborative efforts to develop KID arrays, spectrometers integrated with KIDs, and TKIPs. I optimize a dual polarization TiN KID absorber for the next generation Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry, which is designed to investigate the role magnetic fields play in star formation. As part of an effort to demonstrate aluminum KIDs on sky for CMB polarimetry, I fabricate devices for three design variants. SuperSpec and WSpec are respectively the on-chip and waveguide implementations of a filter bank spectrometer concept designed for survey spectroscopy of high redshift galaxies. I provide a robust tool for characterizing the performance of all SuperSpec devices and demonstrate basic functionality of the first WSpec prototype. As part of an effort to develop the first W-Band (75-110 GHz) TKIP, I construct a cryogenic waveguide feedthrough, which enhances the Astronomical Instrumentation Laboratory's capability to test W-Band devices in general. These efforts contribute to the continued maturation of these kinetic inductance technologies, which will usher in a new era of millimeter-wave astronomy.
Current-phase relations in low carrier density graphene Josephson junctions
NASA Astrophysics Data System (ADS)
Kratz, Philip; Amet, Francois; Watson, Christopher; Moler, Kathryn; Ke, Chung; Borzenets, Ivan; Watanabe, Kenji; Taniguchi, Takashi; Deacon, Russell; Yamamoto, Michihisa; Bomze, Yuriy; Tarucha, Seigo; Finkelstein, Gleb
Ideal Dirac semimetals have the unique property of being gate tunable to arbitrarily low electron and hole carrier concentrations near the Dirac point, without suffering from conduction channel pinch-off or Fermi level pinning to band edges and deep-level charge traps, which are common in typical semiconductors. SNS junctions, where N is a Dirac semimetal, can provide a versatile platform for studying few-mode superconducting weak links, with potential device applications for superconducting logic and qubits. We will use an inductive readout technique, scanning superconducting quantum interference device (SQUID) magnetometry, to measure the current-phase relations of high-mobility graphene SNS junctions as a function of temperature and carrier density, complementing magnetic Fraunhofer diffraction analysis from transport measurements which previously have assumed sinusoidal current-phase relations for junction Andreev modes. Deviations from sinusoidal behavior convey information about resonant scattering processes, dissipation, and ballistic modes in few-mode superconducting weak links.
21 CFR 868.5400 - Electroanesthesia apparatus.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electroanesthesia apparatus. 868.5400 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5400 Electroanesthesia apparatus. (a) Identification. An electroanesthesia apparatus is a device used for the induction and maintenance of anesthesia...
21 CFR 868.5400 - Electroanesthesia apparatus.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electroanesthesia apparatus. 868.5400 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5400 Electroanesthesia apparatus. (a) Identification. An electroanesthesia apparatus is a device used for the induction and maintenance of anesthesia...
Si-compatible cleaning process for graphene using low-density inductively coupled plasma.
Lim, Yeong-Dae; Lee, Dae-Yeong; Shen, Tian-Zi; Ra, Chang-Ho; Choi, Jae-Young; Yoo, Won Jong
2012-05-22
We report a novel cleaning technique for few-layer graphene (FLG) by using inductively coupled plasma (ICP) of Ar with an extremely low plasma density of 3.5 × 10(8) cm(-3). It is known that conventional capacitively coupled plasma (CCP) treatments destroy the planar symmetry of FLG, giving rise to the generation of defects. However, ICP treatment with extremely low plasma density is able to remove polymer resist residues from FLG within 3 min at a room temperature of 300 K while retaining the carbon sp(2)-bonding of FLG. It is found that the carrier mobility and charge neutrality point of FLG are restored to their pristine defect-free state after the ICP treatment. Considering the application of graphene to silicon-based electronic devices, such a cleaning method can replace thermal vacuum annealing, electrical current annealing, and wet-chemical treatment due to its advantages of being a low-temperature, large-area, high-throughput, and Si-compatible process.
An analytical model for inductively coupled implantable biomedical devices with ferrite rods.
Theilmann, P T; Asbeck, P M
2009-02-01
Using approximations applicable to near field coupled implants simplified expressions for the complex mutual inductance of coaxial aligned coils with and without a cylindrical ferrite rod are derived. Experimental results for ferrite rods of various sizes and permeabilities are presented to verify the accuracy of this expression. An equivalent circuit model for the inductive link between an implant and power coil is then presented and used to investigate how ferrite size, permeability and loss affect the power available to the implant device. Enhancements in coupling provided by high frequency, low permeability nickel zinc rods are compared with low frequency high permeability manganese zinc rods.
Technological inductive power transfer systems
NASA Astrophysics Data System (ADS)
Madzharov, Nikolay D.; Nemkov, Valentin S.
2017-05-01
Inductive power transfer is a very fast expanding technology with multiple design principles and practical implementations ranging from charging phones and computers to bionic systems, car chargers and continuous power transfer in technological lines. Only a group of devices working in near magnetic field is considered. This article is devoted to overview of different inductive power transfer (IPT) devices. The review of literature in this area showed that industrial IPT are not much discussed and examined. The authors have experience in design and implementation of several types of IPTs belonging to wireless automotive chargers and to industrial application group. Main attention in the article is paid to principles and design of technological IPTs
Manoufali, Mohamed; Bialkowski, Konstanty; Mohammed, Beadaa Jasem; Mills, Paul C; Abbosh, Amin
2018-01-01
Near-field inductive-coupling link can establish a reliable power source to a batteryless implantable medical device based on Faraday's law of induction. In this paper, the design, modeling, and experimental verification of an inductive-coupling link between an off-body loop antenna and a 0.9 three-dimensional (3-D) bowtie brain implantable antenna is presented. To ensure reliability of the design, the implantable antenna is embedded in the cerebral spinal fluid of a realistic human head model. Exposure, temperature, and propagation simulations of the near electromagnetic fields in a frequency-dispersive head model were carried out to comply with the IEEE safety standards. Concertedly, a fabrication process for the implantable antenna is proposed, which can be extended to devise and miniaturize different 3-D geometric shapes. The performance of the proposed inductive link was tested in a biological environment; in vitro measurements of the fabricated prototypes were carried in a pig's head and piglet. The measurements of the link gain demonstrated in the pig's head and in piglet. The in vitro measurement results showed that the proposed 3-D implantable antenna is suitable for integration with a miniaturized batteryless brain implantable medical device (BIMD).
Soft ferrite cores characterization for integrated micro-inductors
NASA Astrophysics Data System (ADS)
Nguyen, Yen Mai; Lopez, Thomas; Laur, Jean-Pierre; Bourrier, David; Charlot, Samuel; Valdez-Nava, Zarel; Bley, Vincent; Combettes, Céline; Brunet, Magali
2013-12-01
Ferrite-based micro-inductors are proposed for hybrid integration on silicon for low-power medium frequency DC-DC converters. Due to their small coercive field and their high resistivity, soft ferrites are good candidates for a magnetic core working at moderate frequencies in the range of 5-10 MHz. We have studied several soft ferrites including commercial ferrite film and U70 and U200 homemade ferrites. The inductors are fabricated at wafer level using micromachining and assembling techniques. The proposed process is based on a sintered ferrite core placed in between thick electroplated copper windings. The low profile ferrite cores of 1.2 × 2.6 × 0.2 mm3 are produced by two methods from green tape-casted films and ferrite powder. This paper presents the magnetic characterization of the sintered ferrite films cut and printed in rectangular shape and sintered at different temperatures. The comparison is made in order to find out the best material for the core that can reach the required inductance (470 nH at 6 MHz) under 0.6A current DC bias and that generate the smallest losses. An inductance density of 285 nH/ mm2 up to 6 MHz was obtained for ESL 40011 cores that is much higher than the previously reported devices. The small size of our devices is also a prominent point.
NASA Astrophysics Data System (ADS)
Mohamad, Saiful Najmee; Ismail, Fairuz Diana; Noorden, Ahmad Fakhrurrazi Ahmad; Haider, Zuhaib; Ali, Jalil
2017-03-01
Numerous configurations of plasma focus devices (PFD) have been introduced around the globe. The distinct electrode configuration of the PFD will give out different inductance profile. A circuit analysis has been done to study on the significant difference between the inductance evolution in a coaxial discharge based on various published results of PFD. The discharge current signal, tube voltage and current derivative of the particular shots from distinct PFD was digitized and analyze. The investigation was piloted for three different types of PFD. It was observed that there is a significant difference for the normalize inductance profile during the discharge between the individual PFD with different electrode configuration. The depletion of the radial start current with the normalised inductance development for Mather type (PF-1000) is found to be 25.9% from static discharge. The current depletion continues to drop 1.1% and 1.3% more for a Spherical type (PNK-13) and Filippov type (PF-3) respectively.
NASA Astrophysics Data System (ADS)
Barnak, D. H.; Davies, J. R.; Fiksel, G.; Chang, P.-Y.; Zabir, E.; Betti, R.
2018-03-01
Magnetized high energy density physics (HEDP) is a very active and relatively unexplored field that has applications in inertial confinement fusion, astrophysical plasma science, and basic plasma physics. A self-contained device, the Magneto-Inertial Fusion Electrical Discharge System, MIFEDS [G. Fiksel et al., Rev. Sci. Instrum. 86, 016105 (2015)], was developed at the Laboratory for Laser Energetics to conduct magnetized HEDP experiments on both the OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495-506 (1997)] and OMEGA EP [J. H. Kelly et al., J. Phys. IV France 133, 75 (2006) and L. J. Waxer et al., Opt. Photonics News 16, 30 (2005)] laser systems. Extremely high magnetic fields are a necessity for magnetized HEDP, and the need for stronger magnetic fields continues to drive the redevelopment of the MIFEDS device. It is proposed in this paper that a magnetic coil that is inductively coupled rather than directly connecting to the MIFEDS device can increase the overall strength of the magnetic field for HEDP experiments by increasing the efficiency of energy transfer while decreasing the effective magnetized volume. A brief explanation of the energy delivery of the MIFEDS device illustrates the benefit of inductive coupling and is compared to that of direct connection for varying coil size and geometry. A prototype was then constructed to demonstrate a 7-fold increase in energy delivery using inductive coupling.
Nanoscale displacement sensing using microfabricated variable-inductance planar coils
NASA Astrophysics Data System (ADS)
Coskun, M. Bulut; Thotahewa, Kasun; Ying, York-Sing; Yuce, Mehmet; Neild, Adrian; Alan, Tuncay
2013-09-01
Microfabricated spiral inductors were employed for nanoscale displacement detection, suitable for use in implantable pressure sensor applications. We developed a variable inductor sensor consisting of two coaxially positioned planar coils connected in series to a measurement circuit. The devices were characterized by varying the air gap between the coils hence changing the inductance, while a Colpitts oscillator readout was used to obtain corresponding frequencies. Our approach shows significant advantages over existing methodologies combining a displacement resolution of 17 nm and low hysteresis (0.15%) in a 1 × 1 mm2 device. We show that resolution could be further improved by shrinking the device's lateral dimensions.
NASA Astrophysics Data System (ADS)
Singh Dhillon, Navdeep; Pisano, Albert P.
2014-03-01
A novel two-port thermal-flux method has been proposed and demonstrated for degassing and charging two-phase microfluidic thermal transport systems with a degassed working fluid. In microscale heat pipes and loop heat pipes (mLHPs), small device volumes and large capillary forces associated with smaller feature sizes render conventional vacuum pump-based degassing methods quite impractical. Instead, we employ a thermally generated pressure differential to purge non-condensable gases from these devices before charging them with a degassed working fluid in a two-step process. Based on the results of preliminary experiments studying the effectiveness and reliability of three different high temperature-compatible device packaging approaches, an optimized compression packaging technique was developed to degas and charge a mLHP device using the thermal-flux method. An induction heating-based noninvasive hermetic sealing approach for permanently sealing the degassed and charged mLHP devices has also been proposed. To demonstrate the efficacy of this approach, induction heating experiments were performed to noninvasively seal 1 mm square silicon fill-hole samples with donut-shaped solder preforms. The results show that the minimum hole sealing induction heating time is heat flux limited and can be estimated using a lumped capacitance thermal model. However, further continued heating of the solder uncovers the hole due to surface tension-induced contact line dynamics of the molten solder. It was found that an optimum mass of the solder preform is required to ensure a wide enough induction-heating time window for successful sealing of a fill-hole.
NASA Astrophysics Data System (ADS)
Romano, F.; Massuti-Ballester, B.; Binder, T.; Herdrich, G.; Fasoulas, S.; Schönherr, T.
2018-06-01
Challenging space mission scenarios include those in low altitude orbits, where the atmosphere creates significant drag to the S/C and forces their orbit to an early decay. For drag compensation, propulsion systems are needed, requiring propellant to be carried on-board. An atmosphere-breathing electric propulsion system (ABEP) ingests the residual atmosphere particles through an intake and uses them as propellant for an electric thruster. Theoretically applicable to any planet with atmosphere, the system might allow to orbit for unlimited time without carrying propellant. A new range of altitudes for continuous operation would become accessible, enabling new scientific missions while reducing costs. Preliminary studies have shown that the collectible propellant flow for an ion thruster (in LEO) might not be enough, and that electrode erosion due to aggressive gases, such as atomic oxygen, will limit the thruster lifetime. In this paper an inductive plasma thruster (IPT) is considered for the ABEP system. The starting point is a small scale inductively heated plasma generator IPG6-S. These devices are electrodeless and have already shown high electric-to-thermal coupling efficiencies using O2 and CO2 . The system analysis is integrated with IPG6-S tests to assess mean mass-specific energies of the plasma plume and estimate exhaust velocities.
Design and Development of Micro-Power Generating Device for Biomedical Applications of Lab-on-a-Disc
Joseph, Karunan; Ibrahim, Fatimah; Cho, Jongman; Thio, Tzer Hwai Gilbert; Al-Faqheri, Wisam; Madou, Marc
2015-01-01
The development of micro-power generators for centrifugal microfluidic discs enhances the platform as a green point-of-care diagnostic system and eliminates the need for attaching external peripherals to the disc. In this work, we present micro-power generators that harvest energy from the disc’s rotational movement to power biomedical applications on the disc. To implement these ideas, we developed two types of micro-power generators using piezoelectric films and an electromagnetic induction system. The piezoelectric-based generator takes advantage of the film’s vibration during the disc’s rotational motion, whereas the electromagnetic induction-based generator operates on the principle of current generation in stacks of coil exposed to varying magnetic flux. We have successfully demonstrated that at the spinning speed of 800 revolutions per minute (RPM) the piezoelectric film-based generator is able to produce up to 24 microwatts using 6 sets of films and the magnetic induction-based generator is capable of producing up to 125 milliwatts using 6 stacks of coil. As a proof of concept, a custom made localized heating system was constructed to test the capability of the magnetic induction-based generator. The heating system was able to achieve a temperature of 58.62°C at 2200 RPM. This development of lab-on-a-disc micro power generators preserves the portability standards and enhances the future biomedical applications of centrifugal microfluidic platforms. PMID:26422249
Non-inductive improved H-mode operation at ASDEX Upgrade
NASA Astrophysics Data System (ADS)
Bock, A.; Fable, E.; Fischer, R.; Reich, M.; Rittich, D.; Stober, J.; Bernert, M.; Burckhart, A.; Doerk, H.; Dunne, M.; Geiger, B.; Giannone, L.; Igochine, V.; Kappatou, A.; McDermott, R.; Mlynek, A.; Odstrčil, T.; Tardini, G.; Zohm, H.; The ASDEX Upgrade Team
2017-12-01
Recent improvements to the heating and diagnostic systems on the ASDEX Upgrade tokamak allow renewed investigations into non-inductive operation scenarios with improved confinement in a full-metal device. Motivated by this, a scenario with \
Hao, Shiying; Gorjon, Jose; Taylor, Stephen
2014-03-01
This work describes the functions of the external, portable part of a telemetry system for powering and interrogating implantable electrical devices built within orthopaedic implants for real-time data acquisition of strain, load, temperature, humidity and other relevant data (e.g. from inertial sensors). The system contains a battery powered inductive energiser and demodulator to remotely power the implant electronics and demodulate the signals transmitted from the implanted device. Due to the housing of the internal coil, sufficient inductive coupling is obtained between the external and internal tuned circuits to enable simultaneous power and data transmission over the same inductive link. The actual performance of this system when used with one specific implant was studied, and some correspondence made to the relevant theory. Performance factors relating to both power efficiency and data reconstruction were identified. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
Macintosh, David L; Myatt, Theodore A; Ludwig, Jerry F; Baker, Brian J; Suh, Helen H; Spengler, John D
2008-11-01
A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-microm particles ranged from 1.5 hr(-1) during operation of an in-duct, 5-in. pleated media filter to 7.2 hr(-1) for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr(-1) when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 microm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr(-1) under baseline conditions, 0.5 hr(-1) during operation of three portable ionic air cleaners, 1 hr(-1) for an in-duct 1-in. media filter, 2.4 hr(-1) for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr(-1) for an in-duct 5-in. media filter, 4.7 hr(-1) during operation of five portable HEPA filters, 6.1 hr(-1) for a conventional in-duct electronic air cleaner, and 7.5 hr(-1) for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates.
Balberg, Isaac
1981-01-01
A device made of amorphous silicon which exhibits inductive properties at certain voltage biases and in certain frequency ranges in described. Devices of the type described can be made in integrated circuit form.
A Magnetic-Balanced Inductive Link for the Simultaneous Uplink Data and Power Telemetry
Liu, Dake; Li, Min
2017-01-01
When using the conventional two-coil inductive link for the simultaneous wireless power and data transmissions in implantable biomedical sensor devices, the strong power carrier could overwhelm the uplink data signal and even saturate the external uplink receiver. To address this problem, we propose a new magnetic-balanced inductive link for our implantable glaucoma treatment device. In this inductive link, an extra coil is specially added for the uplink receiving. The strong power carrier interference is minimized to approach zero by balanced canceling of the magnetic field of the external power coil. The implant coil is shared by the wireless power harvesting and the uplink data transmitting. Two carriers (i.e., 2-MHz power carrier and 500-kHz uplink carrier) are used for the wireless power transmission and the uplink data transmission separately. In the experiments, the prototype of this link achieves as high as 65.72 dB improvement of the signal-to-interference ratio (SIR) compared with the conventional two-coil inductive link. Benefiting from the significant improvement of SIR, the implant transmitter costs only 0.2 mW of power carrying 50 kbps of binary phase shift keying data and gets a bit error rate of 1 × 10−7, even though the coupling coefficient is as low as 0.005. At the same time, 5 mW is delivered to the load with maximum power transfer efficiency of 58.8%. This magnetic-balanced inductive link is useful for small-sized biomedical sensor devices, which require transmitting data and power simultaneously under ultra-weak coupling. PMID:28767090
A Magnetic-Balanced Inductive Link for the Simultaneous Uplink Data and Power Telemetry.
Gong, Chen; Liu, Dake; Miao, Zhidong; Li, Min
2017-08-02
When using the conventional two-coil inductive link for the simultaneous wireless power and data transmissions in implantable biomedical sensor devices, the strong power carrier could overwhelm the uplink data signal and even saturate the external uplink receiver. To address this problem, we propose a new magnetic-balanced inductive link for our implantable glaucoma treatment device. In this inductive link, an extra coil is specially added for the uplink receiving. The strong power carrier interference is minimized to approach zero by balanced canceling of the magnetic field of the external power coil. The implant coil is shared by the wireless power harvesting and the uplink data transmitting. Two carriers (i.e., 2-MHz power carrier and 500-kHz uplink carrier) are used for the wireless power transmission and the uplink data transmission separately. In the experiments, the prototype of this link achieves as high as 65.72 dB improvement of the signal-to-interference ratio (SIR) compared with the conventional two-coil inductive link. Benefiting from the significant improvement of SIR, the implant transmitter costs only 0.2 mW of power carrying 50 kbps of binary phase shift keying data and gets a bit error rate of 1 × 10 - 7 , even though the coupling coefficient is as low as 0.005. At the same time, 5 mW is delivered to the load with maximum power transfer efficiency of 58.8%. This magnetic-balanced inductive link is useful for small-sized biomedical sensor devices, which require transmitting data and power simultaneously under ultra-weak coupling.
Magnetic Calorimeter Arrays with High Sensor Inductance and Dense Wiring
NASA Astrophysics Data System (ADS)
Stevenson, T. R.; Balvin, M. A.; Bandler, S. R.; Devasia, A. M.; Nagler, P. C.; Smith, S. J.; Yoon, W.
2018-05-01
We describe prototype arrays of magnetically coupled microcalorimeters fabricated with an approach scalable to very large format arrays. The superconducting interconnections and sensor coils have sufficiently low inductance in the wiring and sufficiently high inductance in the coils in each pixel, to enable arrays containing greater than 4000 sensors and 100,000 X-ray absorbers to be used in future astrophysics missions such as Lynx. We have used projection lithography to create submicron patterns (e.g., 400 nm lines and spaces) in our niobium sensor coils and wiring, integrated with gold-erbium sensor films and gold X-ray absorbers. Our prototype devices will explore the device physics of metallic magnetic calorimeters as feature sizes are reduced to nanoscale.
Reproducible and controllable induction voltage adder for scaled beam experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sakai, Yasuo; Nakajima, Mitsuo; Horioka, Kazuhiko
2016-08-15
A reproducible and controllable induction adder was developed using solid-state switching devices and Finemet cores for scaled beam compression experiments. A gate controlled MOSFET circuit was developed for the controllable voltage driver. The MOSFET circuit drove the induction adder at low magnetization levels of the cores which enabled us to form reproducible modulation voltages with jitter less than 0.3 ns. Preliminary beam compression experiments indicated that the induction adder can improve the reproducibility of modulation voltages and advance the beam physics experiments.
Effects of Inductively Coupled Plasma Hydrogen on Long-Wavelength Infrared HgCdTe Photodiodes
NASA Astrophysics Data System (ADS)
Boieriu, P.; Buurma, C.; Bommena, R.; Blissett, C.; Grein, C.; Sivananthan, S.
2013-12-01
Bulk passivation of semiconductors with hydrogen continues to be investigated for its potential to improve device performance. In this work, hydrogen-only inductively coupled plasma (ICP) was used to incorporate hydrogen into long-wavelength infrared HgCdTe photodiodes grown by molecular-beam epitaxy. Fully fabricated devices exposed to ICP showed statistically significant increases in zero-bias impedance values, improved uniformity, and decreased dark currents. HgCdTe photodiodes on Si substrates passivated with amorphous ZnS exhibited reductions in shunt currents, whereas devices on CdZnTe substrates passivated with polycrystalline CdTe exhibited reduced surface leakage, suggesting that hydrogen passivates defects in bulk HgCdTe and in CdTe.
Induction simulation of gas core nuclear engine
NASA Technical Reports Server (NTRS)
Poole, J. W.; Vogel, C. E.
1973-01-01
The design, construction and operation of an induction heated plasma device known as a combined principles simulator is discussed. This device incorporates the major design features of the gas core nuclear rocket engine such as solid feed, propellant seeding, propellant injection through the walls, and a transpiration cooled, choked flow nozzle. Both argon and nitrogen were used as propellant simulating material, and sodium was used for fuel simulating material. In addition, a number of experiments were conducted utilizing depleted uranium as the fuel. The test program revealed that satisfactory operation of this device can be accomplished over a range of operating conditions and provided additional data to confirm the validity of the gas core concept.
NASA Astrophysics Data System (ADS)
Penna, James; Morgan, Kyle; Grubb, Isaac; Jarboe, Thomas
2017-10-01
The Helicity Injected Torus - Steady Inductive 3 (HIT-SI3) experiment forms and maintains spheromaks via Steady Inductive Helicity Injection (SIHI) using discrete injectors that inject magnetic helicity via a non-axisymmetric perturbation and drive toroidally symmetric current. Newer designs for larger SIHI-driven spheromaks incorporate a set of injectors connected to a single external manifold to allow more freedom for the toroidal structure of the applied perturbation. Simulations have been carried out using the NIMROD code to assess the effectiveness of various imposed mode structures and injector schema in driving current via Imposed Dynamo Current Drive (IDCD). The results are presented here for varying flux conserver shapes on a device approximately 1.5 times larger than the current HIT-SI3 experiment. The imposed mode structures and spectra of simulated spheromaks are analyzed in order to examine magnetic structure and stability and determine an optimal regime for IDCD sustainment in a large device. The development of scaling laws for manifold operation is also presented, and simulation results are analyzed and assessed as part of the development path for the large scale device.
Nanoscale superconducting memory based on the kinetic inductance of asymmetric nanowire loops
NASA Astrophysics Data System (ADS)
Murphy, Andrew; Averin, Dmitri V.; Bezryadin, Alexey
2017-06-01
The demand for low-dissipation nanoscale memory devices is as strong as ever. As Moore’s law is staggering, and the demand for a low-power-consuming supercomputer is high, the goal of making information processing circuits out of superconductors is one of the central goals of modern technology and physics. So far, digital superconducting circuits could not demonstrate their immense potential. One important reason for this is that a dense superconducting memory technology is not yet available. Miniaturization of traditional superconducting quantum interference devices is difficult below a few micrometers because their operation relies on the geometric inductance of the superconducting loop. Magnetic memories do allow nanometer-scale miniaturization, but they are not purely superconducting (Baek et al 2014 Nat. Commun. 5 3888). Our approach is to make nanometer scale memory cells based on the kinetic inductance (and not geometric inductance) of superconducting nanowire loops, which have already shown many fascinating properties (Aprili 2006 Nat. Nanotechnol. 1 15; Hopkins et al 2005 Science 308 1762). This allows much smaller devices and naturally eliminates magnetic-field cross-talk. We demonstrate that the vorticity, i.e., the winding number of the order parameter, of a closed superconducting loop can be used for realizing a nanoscale nonvolatile memory device. We demonstrate how to alter the vorticity in a controlled fashion by applying calibrated current pulses. A reliable read-out of the memory is also demonstrated. We present arguments that such memory can be developed to operate without energy dissipation.
Tunable MOEMS Fabry-Perot interferometer for miniaturized spectral sensing in near-infrared
NASA Astrophysics Data System (ADS)
Rissanen, A.; Mannila, R.; Tuohiniemi, M.; Akujärvi, A.; Antila, J.
2014-03-01
This paper presents a novel MOEMS Fabry-Perot interferometer (FPI) process platform for the range of 800 - 1050 nm. Simulation results including design and optimization of device properties in terms of transmission peak width, tuning range and electrical properties are discussed. Process flow for the device fabrication is presented, with overall process integration and backend dicing steps resulting in successful fabrication yield. The mirrors of the FPI consist of LPCVD (low-pressure chemical vapor) deposited polySi-SiN λ/4-thin film Bragg reflectors, with the air gap formed by sacrificial SiO2 etching in HF vapor. Silicon substrate below the optical aperture is removed by inductively coupled plasma (ICP) etching to ensure transmission in the visible - near infra-red (NIR), which is below silicon transmission range. The characterized optical properties of the chips are compared to the simulated values. Achieved optical aperture diameter size enables utilization of the chips in both imaging as well as single-point spectral sensors.
NASA Technical Reports Server (NTRS)
Thompson, J. A.
1977-01-01
Lightweight device automatically alines stainless-steel tubing and fittings, regardless of differing diameters, prior to joining via induction brazing. Device is useful in remote areas where existing supports or walls cannot be used to anchor tubing holder.
Work zone speed reduction utilizing dynamic speed signs
DOT National Transportation Integrated Search
2011-08-30
Vast quantities of transportation data are automatically recorded by intelligent transportations infrastructure, such as inductive loop detectors, video cameras, and side-fire radar devices. Such devices are typically deployed by traffic management c...
Modeling of power control schemes in induction cooking devices
NASA Astrophysics Data System (ADS)
Beato, Alessio; Conti, Massimo; Turchetti, Claudio; Orcioni, Simone
2005-06-01
In recent years, with remarkable advancements of power semiconductor devices and electronic control systems, it becomes possible to apply the induction heating technique for domestic use. In order to achieve the supply power required by these devices, high-frequency resonant inverters are used: the force commutated, half-bridge series resonant converter is well suited for induction cooking since it offers an appropriate balance between complexity and performances. Power control is a key issue to attain efficient and reliable products. This paper describes and compares four power control schemes applied to the half-bridge series resonant inverter. The pulse frequency modulation is the most common control scheme: according to this strategy, the output power is regulated by varying the switching frequency of the inverter circuit. Other considered methods, originally developed for induction heating industrial applications, are: pulse amplitude modulation, asymmetrical duty cycle and pulse density modulation which are respectively based on variation of the amplitude of the input supply voltage, on variation of the duty cycle of the switching signals and on variation of the number of switching pulses. Each description is provided with a detailed mathematical analysis; an analytical model, built to simulate the circuit topology, is implemented in the Matlab environment in order to obtain the steady-state values and waveforms of currents and voltages. For purposes of this study, switches and all reactive components are modelled as ideal and the "heating-coil/pan" system is represented by an equivalent circuit made up of a series connected resistance and inductance.
Electromagnetic induction sensor for dynamic testing of coagulation process.
Wang, Zhe; Yu, Yuanhua; Yu, Zhanjiang; Chen, Qimeng
2018-03-01
With the increasing demand for coagulation POCT for patients in the surgery department or the ICU, rapid coagulation testing techniques and methods have drawn widespread attention from scholars and businessmen. This paper proposes the use of electromagnetic induction sensor probe for detection of dynamic process causing changes in the blood viscosity and density before and after coagulation based on the damped vibration principle, in order to evaluate the coagulation status. Utilizing the dynamic principle, the differential equation of vibration system comprising elastic support and electromagnetic induction device is established through sensor dynamic modeling. The structural parameters of elastic support are optimized, and the circular sheet spring is designed. Furthermore, harmonic response analysis and vibration fatigue coupling analysis are performed on the elastic support of the sensor by considering the natural frequency of the system, and the electromagnetic induction sensor testing device is set up. Using the device and coagulation reagent, the standard curve for coagulation POCT is plotted, and the blood sample application in clinical patients is established, which are methodologically compared with the imported POCT coagulation analyzer. The results show that the sensor designed in this paper has a first-order natural frequency of 11.368 Hz, which can withstand 5.295 × 10 2 million times of compressions and rebounds. Its correlation with the results of SONOCLOT analyzer reaches 0.996, and the reproducibility 0.002. The electromagnetic induction coagulation testing sensor designed has good elasticity and anti-fatigue, which can meet the accuracy requirement of clinical detection. This study provides the core technology for developing the electromagnetic induction POCT instrument for dynamic testing of coagulation process.
NASA Astrophysics Data System (ADS)
Baksht, E. Kh; Panchenko, Aleksei N.; Tarasenko, Viktor F.
2000-06-01
An efficient electric-discharge XeCl laser is developed, which is pumped by a self-sustained discharge with a prepulse formed by a generator with an inductive energy storage device and a semiconductor current interrupter on a basis of semiconductor opening switch (SOS) diodes. An output energy up to 800 mJ, a pulse length up to 450 ns, and a total laser efficiency of 2.2% were attained by using spark UV preionisation.
NASA Astrophysics Data System (ADS)
Bunge, Mario
2011-05-01
Pseudoscience is error, substantive or methodological, parading as science. Obvious examples are parapsychology, "intelligent design," and homeopathy. Psychoanalysis and pop evolutionary psychology are less obvious, yet no less flawed in both method and doctrine. The fact that science can be faked to the point of deceiving science lovers suggests the need for a rigorous sifting device, one capable of revealing out the worm in the apple. This device is needed to evaluate research proposal as well as new fashions. Such a device can be designed only with the help of a correct definition of science, one attending not only to methodological aspects, such as testability and predictive power, but also to other features of scientific knowledge, such as intelligibility, corrigibility, and compatibility with the bulk of antecedent knowledge. The aim of this paper is to suggest such a criterion, to illustrate it with a handful of topical examples, and to emphasize the role of philosophy in either promoting or blocking scientific progress. This article is a revised version of a chapter in the author's forthcoming book Matter and Mind (Springer). [The Appendix on inductive logic was written at the request of the editors in order to elaborate claims made in #10 (4).
Two frameworks for integrating knowledge in induction
NASA Technical Reports Server (NTRS)
Rosenbloom, Paul S.; Hirsh, Haym; Cohen, William W.; Smith, Benjamin D.
1994-01-01
The use of knowledge in inductive learning is critical for improving the quality of the concept definitions generated, reducing the number of examples required in order to learn effective concept definitions, and reducing the computation needed to find good concept definitions. Relevant knowledge may come in many forms (such as examples, descriptions, advice, and constraints) and from many sources (such as books, teachers, databases, and scientific instruments). How to extract the relevant knowledge from this plethora of possibilities, and then to integrate it together so as to appropriately affect the induction process is perhaps the key issue at this point in inductive learning. Here the focus is on the integration part of this problem; that is, how induction algorithms can, and do, utilize a range of extracted knowledge. Preliminary work on a transformational framework for defining knowledge-intensive inductive algorithms out of relatively knowledge-free algorithms is described, as is a more tentative problems-space framework that attempts to cover all induction algorithms within a single general approach. These frameworks help to organize what is known about current knowledge-intensive induction algorithms, and to point towards new algorithms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ekdahl, C.A.
In experiments involving pulsed high magnetic fields the appearance of the full induced voltage at the output terminals of large-area inductive sensors such as diamagnetic loops and Rogowski belts imposes severe requirements on the insulation near the output. Capacitive detection of the inductive-sensor output voltage provides an ideal geometry for high-voltage insulation, and also accomplishes the necessary voltage division. An inductive-shunt current monitor was designed to utilize the capacitive-detection principle. The contruction of this device and its performance are described in this paper.
Numerical analysis method for linear induction machines.
NASA Technical Reports Server (NTRS)
Elliott, D. G.
1972-01-01
A numerical analysis method has been developed for linear induction machines such as liquid metal MHD pumps and generators and linear motors. Arbitrary phase currents or voltages can be specified and the moving conductor can have arbitrary velocity and conductivity variations from point to point. The moving conductor is divided into a mesh and coefficients are calculated for the voltage induced at each mesh point by unit current at every other mesh point. Combining the coefficients with the mesh resistances yields a set of simultaneous equations which are solved for the unknown currents.
Chemical waste disposal in space by plasma discharge
NASA Technical Reports Server (NTRS)
Baird, James K.
1991-01-01
An inductively coupled plasma discharge apparatus operating at 13.56 MHz and with electrical power up to 2.5 kW was constructed. The efficiency of this device to destroy various gases expected to be carried aboard the Space Station was tested. By expressing the efficiency of the device in terms of G-value (the number of molecules decomposed per 100 eV of energy absorbed), the results are compared with known efficiencies of ionizing radiation to destroy these same gases. In the case of ammonia, it was found that in the inductively coupled device, the destruction efficiency, G(-NH3) varied from 6.0 to 32.0 molecules/100 eV, depending on conditions. It was also found that capacitatively coupled discharges were less efficient in destroying NH2 than the inductively coupled discharge. In the case NH2 destruction, it was found that the G(-NH3) was a qualitative guide to the efficiencies of plasmas. The plasma device was also used to destroy nitrous oxide and methane. It is shown how the G-value for the destruction of any gas can be computed theoretically from a knowledge of the electron velocity distribution, the various electron molecule scattering cross sections, and the rate constants for the reactions of secondary species.
Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission.
Kiani, Mehdi; Jow, Uei-Ming; Ghovanloo, Maysam
2011-07-14
Inductive power transmission is widely used to energize implantable microelectronic devices (IMDs), recharge batteries, and energy harvesters. Power transfer efficiency (PTE) and power delivered to the load (PDL) are two key parameters in wireless links, which affect the energy source specifications, heat dissipation, power transmission range, and interference with other devices. To improve the PTE, a 4-coil inductive link has been recently proposed. Through a comprehensive circuit based analysis that can guide a design and optimization scheme, we have shown that despite achieving high PTE at larger coil separations, the 4-coil inductive links fail to achieve a high PDL. Instead, we have proposed a 3-coil inductive power transfer link with comparable PTE over its 4-coil counterpart at large coupling distances, which can also achieve high PDL. We have also devised an iterative design methodology that provides the optimal coil geometries in a 3-coil inductive power transfer link. Design examples of 2-, 3-, and 4-coil inductive links have been presented, and optimized for 13.56 MHz carrier frequency and 12 cm coupling distance, showing PTEs of 15%, 37%, and 35%, respectively. At this distance, the PDL of the proposed 3-coil inductive link is 1.5 and 59 times higher than its equivalent 2- and 4-coil links, respectively. For short coupling distances, however, 2-coil links remain the optimal choice when a high PDL is required, while 4-coil links are preferred when the driver has large output resistance or small power is needed. These results have been verified through simulations and measurements.
An ultrasonic nebulizer (USN) was utilized as a sample introduction device for an inductively coupled plasma mass spectrometer in an attempt to increase the sensitivity for As. The USN produced a valence state response difference for As. The As response was suppressed approximate...
Daniels, Roger L; Kim, Hyun Jung; Min, David B
2006-08-09
Soybean oil with an iodine value of 136 was hydrogenated to have iodine values of 126 and 117. The soybean oils with iodine values of 136, 126, and 117 were randomly interesterified using sodium methoxide. The oxidative stabilities of the hydrogenated and/or interesterified soybean oils were evaluated by measuring the headspace oxygen content by gas chromatography, and the induction time was measured using Rancimat. The melting points of the oils were evaluated by differential scanning calorimetry. Duncan's multiple range test of the headspace oxygen and induction time showed that hydrogenation increased the headspace oxygen content and induction time at alpha = 0.05. Interesterification decreased the headspace oxygen and the induction time for the soybean oils with iodine values of 136, 126, and 117 at alpha = 0.05. Hydrogenation increased the melting points as the iodine value decreased from 136 and 126 to 117 at alpha = 0.05. The random interesterification increased the melting points of soybean oils with iodine values of 136, 126, and 117 at alpha = 0.05. The combined effects of hydrogenation and interesterification increased the oxidative stability of soybean oil at alpha = 0.05 and the melting point at alpha = 0.01. The optimum combination of hydrogenation and random interesterification can improve the oxidative stability and increase the melting point to expand the application of soybean oil in foods.
ERIC Educational Resources Information Center
Sloutsky, Vladimir M.; Fisher, Anna V.
2006-01-01
This article is a response to E. Heit and B. K. Hayes's comment on the target article "Induction and Categorization in Young Children: A Similarity-Based Model" (V. M. Sloutsky & A. V. Fisher, 2004a). The response discusses points of agreement and disagreement with Heit and Hayes; phenomena predicted by similarity, induction, naming, and…
NASA Astrophysics Data System (ADS)
Tian, Ye; Yang, Zhuo; Xu, Zhiyuan; Liu, Siyang; Sun, Weifeng; Shi, Longxing; Zhu, Yuanzheng; Ye, Peng; Zhou, Jincheng
2018-04-01
In this paper, a novel failure mechanism under unclamped inductive switch (UIS) for Split-Gate Trench Metal Oxide Semiconductor Field Effect Transistor (MOSFET) with large current is investigated. The device sample is tested and analyzed in detail. The simulation results demonstrate that the nonuniform potential distribution of the source poly should be responsible for the failure. Three structures are proposed and verified available to improve the device UIS ruggedness by TCAD simulation. The best one of the structures the device with source metal inserting into source poly through contacts in the field oxide is carried out and measured. The results demonstrate that the optimized structure can balance the trade-off between the UIS ruggedness and the static characteristics.
Energy harvesting for the implantable biomedical devices: issues and challenges.
Hannan, Mahammad A; Mutashar, Saad; Samad, Salina A; Hussain, Aini
2014-06-20
The development of implanted devices is essential because of their direct effect on the lives and safety of humanity. This paper presents the current issues and challenges related to all methods used to harvest energy for implantable biomedical devices. The advantages, disadvantages, and future trends of each method are discussed. The concept of harvesting energy from environmental sources and human body motion for implantable devices has gained a new relevance. In this review, the harvesting kinetic, electromagnetic, thermal and infrared radiant energies are discussed. Current issues and challenges related to the typical applications of these methods for energy harvesting are illustrated. Suggestions and discussion of the progress of research on implantable devices are also provided. This review is expected to increase research efforts to develop the battery-less implantable devices with reduced over hole size, low power, high efficiency, high data rate, and improved reliability and feasibility. Based on current literature, we believe that the inductive coupling link is the suitable method to be used to power the battery-less devices. Therefore, in this study, the power efficiency of the inductive coupling method is validated by MATLAB based on suggested values. By further researching and improvements, in the future the implantable and portable medical devices are expected to be free of batteries.
Energy harvesting for the implantable biomedical devices: issues and challenges
2014-01-01
The development of implanted devices is essential because of their direct effect on the lives and safety of humanity. This paper presents the current issues and challenges related to all methods used to harvest energy for implantable biomedical devices. The advantages, disadvantages, and future trends of each method are discussed. The concept of harvesting energy from environmental sources and human body motion for implantable devices has gained a new relevance. In this review, the harvesting kinetic, electromagnetic, thermal and infrared radiant energies are discussed. Current issues and challenges related to the typical applications of these methods for energy harvesting are illustrated. Suggestions and discussion of the progress of research on implantable devices are also provided. This review is expected to increase research efforts to develop the battery-less implantable devices with reduced over hole size, low power, high efficiency, high data rate, and improved reliability and feasibility. Based on current literature, we believe that the inductive coupling link is the suitable method to be used to power the battery-less devices. Therefore, in this study, the power efficiency of the inductive coupling method is validated by MATLAB based on suggested values. By further researching and improvements, in the future the implantable and portable medical devices are expected to be free of batteries. PMID:24950601
Multi-input and binary reproducible, high bandwidth floating point adder in a collective network
Chen, Dong; Eisley, Noel A.; Heidelberger, Philip; Steinmacher-Burow, Burkhard
2016-11-15
To add floating point numbers in a parallel computing system, a collective logic device receives the floating point numbers from computing nodes. The collective logic devices converts the floating point numbers to integer numbers. The collective logic device adds the integer numbers and generating a summation of the integer numbers. The collective logic device converts the summation to a floating point number. The collective logic device performs the receiving, the converting the floating point numbers, the adding, the generating and the converting the summation in one pass. One pass indicates that the computing nodes send inputs only once to the collective logic device and receive outputs only once from the collective logic device.
Kutsumi, Osamu; Kato, Yushi; Matsui, Yuuki; Kitagawa, Atsushi; Muramatsu, Masayuki; Uchida, Takashi; Yoshida, Yoshikazu; Sato, Fuminobu; Iida, Toshiyuki
2010-02-01
Multicharged ions that are needed are produced from solid pure material with high melting point in an electron cyclotron resonance ion source. We develop an evaporator by using induction heating (IH) with multilayer induction coil, which is made from bare molybdenum or tungsten wire without water cooling and surrounding the pure vaporized material. We optimize the shapes of induction coil and vaporized materials and operation of rf power supply. We conduct experiment to investigate the reproducibility and stability in the operation and heating efficiency. IH evaporator produces pure material vapor because materials directly heated by eddy currents have no contact with insulated materials, which are usually impurity gas sources. The power and the frequency of the induction currents range from 100 to 900 W and from 48 to 23 kHz, respectively. The working pressure is about 10(-4)-10(-3) Pa. We measure the temperature of the vaporized materials with different shapes, and compare them with the result of modeling. We estimate the efficiency of the IH vapor source. We are aiming at the evaporator's higher melting point material than that of iron.
NASA Astrophysics Data System (ADS)
Kutsumi, Osamu; Kato, Yushi; Matsui, Yuuki; Kitagawa, Atsushi; Muramatsu, Masayuki; Uchida, Takashi; Yoshida, Yoshikazu; Sato, Fuminobu; Iida, Toshiyuki
2010-02-01
Multicharged ions that are needed are produced from solid pure material with high melting point in an electron cyclotron resonance ion source. We develop an evaporator by using induction heating (IH) with multilayer induction coil, which is made from bare molybdenum or tungsten wire without water cooling and surrounding the pure vaporized material. We optimize the shapes of induction coil and vaporized materials and operation of rf power supply. We conduct experiment to investigate the reproducibility and stability in the operation and heating efficiency. IH evaporator produces pure material vapor because materials directly heated by eddy currents have no contact with insulated materials, which are usually impurity gas sources. The power and the frequency of the induction currents range from 100to900W and from 48to23kHz, respectively. The working pressure is about 10-4-10-3Pa. We measure the temperature of the vaporized materials with different shapes, and compare them with the result of modeling. We estimate the efficiency of the IH vapor source. We are aiming at the evaporator's higher melting point material than that of iron.
Using the Art of Trompe L'Oeil to Research Induction and Mentoring
ERIC Educational Resources Information Center
Kirkby, Jane; Moss, Julianne; Godinho, Sally
2015-01-01
This paper reveals how the art device of trompe l'oeil provided a way of thinking about the induction and mentoring experiences of seven beginning teachers in secondary school settings in the state of Victoria, Australia. The research study--a phenomenological, narrative inquiry--drew on Bourdieu's theorising of "misrecognition" and…
Jo, Sung-Eun; Joung, Sanghoon; Suh, Jun-Kyo Francis; Kim, Yong-Jun
2012-09-01
Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condition. It was confirmed that the CMC coil had higher transmission efficiency than typical air-core coil. The power transmission efficiency during a misalignment between primary coil and implanted secondary coil was also evaluated. The decrease of mutual inductance between the two coils caused by the misalignment led to a low efficiency of the inductive link. Therefore, it is important to properly align the primary coil and implanted secondary coil for effective power transmission. To align the coils, a feedback coil was proposed. This was integrated on the backside of the primary coil and enabled the detection of a misalignment of the primary and secondary coils. As a result of using the feedback coil, the primary and secondary coils could be aligned without knowledge of the position of the implanted secondary coil.
Multi-input and binary reproducible, high bandwidth floating point adder in a collective network
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Dong; Eisley, Noel A; Heidelberger, Philip
To add floating point numbers in a parallel computing system, a collective logic device receives the floating point numbers from computing nodes. The collective logic devices converts the floating point numbers to integer numbers. The collective logic device adds the integer numbers and generating a summation of the integer numbers. The collective logic device converts the summation to a floating point number. The collective logic device performs the receiving, the converting the floating point numbers, the adding, the generating and the converting the summation in one pass. One pass indicates that the computing nodes send inputs only once to themore » collective logic device and receive outputs only once from the collective logic device.« less
Plasma Measurements in an Integrated-System FARAD Thruster
NASA Technical Reports Server (NTRS)
Polzin, K. A.; Rose, M. F.; Miller, R.; Best, S.
2007-01-01
Pulsed inductive plasma accelerators are spacecraft propulsion devices in which energy is stored in a capacitor and then discharged through an inductive coil. The device is electrodeless, inducing a current sheet in a plasma located near the face of the coil. The propellant is accelerated and expelled at a high exhaust velocity (order of 10 km/s) through the interaction of the plasma current and the induced magnetic field. The Faraday Accelerator with RF-Assisted Discharge (FARAD) thruster[1,2] is a type of pulsed inductive plasma accelerator in which the plasma is preionized by a mechanism separate from that used to form the current sheet and accelerate the gas. Employing a separate preionization mechanism allows for the formation of an inductive current sheet at much lower discharge energies and voltages than those used in previous pulsed inductive accelerators like the Pulsed Inductive Thruster (PIT). A benchtop FARAD thruster was designed following guidelines and similarity performance parameters presented in Refs. [3,4]. This design is described in detail in Ref. [5]. In this paper, we present the temporally and spatially resolved measurements of the preionized plasma and inductively-accelerated current sheet in the FARAD thruster operating with a Vector Inversion Generator (VIG) to preionize the gas and a Bernardes and Merryman circuit topology to provide inductive acceleration. The acceleration stage operates on the order of 100 J/pulse. Fast-framing photography will be used to produce a time-resolved, global view of the evolving current sheet. Local diagnostics used include a fast ionization gauge capable of mapping the gas distribution prior to plasma initiation; direct measurement of the induced magnetic field using B-dot probes, induced azimuthal current measurement using a mini-Rogowski coil, and direct probing of the number density and electron temperature using triple probes.
Electronic materials testing in commercial aircraft engines
NASA Astrophysics Data System (ADS)
Brand, Dieter
A device for the electronic testing of materials used in commercial aircraft engines is described. The instrument can be used for ferromagnetic, ferrimagnetic, and nonferromagnetic metallic materials, and it functions either optically or acoustically. The design of the device is described and technical data are given. The device operates under the principle of controlled self-inductivity. Its mode of operation is described.
Biofeedback With Implanted Blood-Pressure Device
NASA Technical Reports Server (NTRS)
Rischell, Robert E.
1988-01-01
Additional uses found for equipment described in "Implanted Blood-Pressure-Measuring Device" (GSC-13042). Implanted with device electronic circuitry that measures, interprets, and transmits data via inductive link through patient's skin to external receiver. Receiver includes audible alarm generator activated when patient's blood pressure exceeds predetermined threshold. Also included in receiver a blood-pressure display, recorder, or both, for use by patient or physician.
Tungsten devices in analytical atomic spectrometry
NASA Astrophysics Data System (ADS)
Hou, Xiandeng; Jones, Bradley T.
2002-04-01
Tungsten devices have been employed in analytical atomic spectrometry for approximately 30 years. Most of these atomizers can be electrically heated up to 3000 °C at very high heating rates, with a simple power supply. Usually, a tungsten device is employed in one of two modes: as an electrothermal atomizer with which the sample vapor is probed directly, or as an electrothermal vaporizer, which produces a sample aerosol that is then carried to a separate atomizer for analysis. Tungsten devices may take various physical shapes: tubes, cups, boats, ribbons, wires, filaments, coils and loops. Most of these orientations have been applied to many analytical techniques, such as atomic absorption spectrometry, atomic emission spectrometry, atomic fluorescence spectrometry, laser excited atomic fluorescence spectrometry, metastable transfer emission spectroscopy, inductively coupled plasma optical emission spectrometry, inductively coupled plasma mass spectrometry and microwave plasma atomic spectrometry. The analytical figures of merit and the practical applications reported for these techniques are reviewed. Atomization mechanisms reported for tungsten atomizers are also briefly summarized. In addition, less common applications of tungsten devices are discussed, including analyte preconcentration by adsorption or electrodeposition and electrothermal separation of analytes prior to analysis. Tungsten atomization devices continue to provide simple, versatile alternatives for analytical atomic spectrometry.
NASA Technical Reports Server (NTRS)
Mackey, Jon; Sehirlioglu, Alp; Dynys, Fred
2014-01-01
A set of convenient thermoelectric device solutions have been derived in order to capture a number of factors which are previously only resolved with numerical techniques. The concise conversion efficiency equations derived from governing equations provide intuitive and straight-forward design guidelines. These guidelines allow for better device design without requiring detailed numerical modeling. The analytical modeling accounts for factors such as i) variable temperature boundary conditions, ii) lateral heat transfer, iii) temperature variable material properties, and iv) transient operation. New dimensionless parameters, similar to the figure of merit, are introduced including the device design factor, fin factor, thermal diffusivity factor, and inductance factor. These new device factors allow for the straight-forward description of phenomenon generally only captured with numerical work otherwise. As an example a device design factor of 0.38, which accounts for thermal resistance of the hot and cold shoes, can be used to calculate a conversion efficiency of 2.28 while the ideal conversion efficiency based on figure of merit alone would be 6.15. Likewise an ideal couple with efficiency of 6.15 will be reduced to 5.33 when lateral heat is accounted for with a fin factor of 1.0.
A study on geometry effect of transmission coil for micro size magnetic induction coil
NASA Astrophysics Data System (ADS)
Lee, Kyung Hwa; Jun, Byoung Ok; Kim, Seunguk; Lee, Gwang Jun; Ryu, Mingyu; Choi, Ji-Woong; Jang, Jae Eun
2016-05-01
The effects of transmission (Tx) coil structure have been studied for micro-size magnetic induction coil. The size of the receiving (Rx) coil should be shrunk to the micrometer level for the various new applications such as micro-robot and wireless body implanted devices. In case of the macro-scale magnetic induction coil, the power transmission efficiency is generally considered to be higher as the inductance of the transmission coil became larger; however, the large size difference between macro-size Tx coil and micro-size Rx coil can decrease the power transmission efficiency due to the difference of resonance frequency. Here, we study a correlation of the power transmission with the size and distance between the macro-size Tx and micro-size Rx coils using magnetic induction technique. The maximum power efficiency was 0.28/0.23/0.13/0.12% at the distance of 0.3/1/3/5 cm between Rx and Tx coil. In addition, more efficient wireless power transferring method is suggested with a floating coil for the body implantable devices. The voltage output increased up to 5.4 mV than the original one Tx coil system. The results demonstrated the foundational wireless power transferring system with enhanced power efficiency.
Magneto-therapy of human joint cartilage.
Wierzcholski, Krzysztof; Miszczak, Andrzej
2017-01-01
The topic of the present paper concerns the human joint cartilage therapy performed by the magnetic induction field. There is proved the thesis that the applied magnetic field for concrete cartilage illness should depend on the proper relative and concrete values of applied magnetic induction, intensity as well the time of treatment duration. Additionally, very important are frequencies and amplitudes of magnetic field as well as magnetic permeability of the synovial fluid. The research methods used in this paper include: magnetic induction field produced by a new Polish and German magneto electronic devices for the therapy of human joint cartilage diseases, stationary and movable magnetic applicators, magnetic bandage, ferrofluid injections, author's experience gained in Germany research institutes and practical results after measurements and information from patients. The results of this paper concern concrete parameters of time dependent electro-magnetic field administration during the joint cartilage therapy duration and additionally concern the corollaries which are implied from reading values gained on the magnetic induction devices. The main conclusions obtained in this paper are as follows: Time dependent magnetic induction field increases the dynamic viscosity of movable synovial fluid and decreases symptoms of cartilage illness for concrete intensity of magnetic field and concrete field line architecture. The ferrofluid therapy and phospholipids bilayer simultaneously with the administrated external electromagnetic field, increases the dynamic viscosity of movable synovial fluid.
21 CFR 872.3830 - Endodontic paper point.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Endodontic paper point. 872.3830 Section 872.3830...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3830 Endodontic paper point. (a) Identification. An endodontic paper point is a device made of paper intended for use during endodontic therapy to dry...
21 CFR 872.3830 - Endodontic paper point.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endodontic paper point. 872.3830 Section 872.3830...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3830 Endodontic paper point. (a) Identification. An endodontic paper point is a device made of paper intended for use during endodontic therapy to dry...
A wireless power transmission system for implantable devices in freely moving rodents.
Eom, Kyungsik; Jeong, Joonsoo; Lee, Tae Hyung; Kim, Jinhyung; Kim, Junghoon; Lee, Sung Eun; Kim, Sung June
2014-08-01
Reliable wireless power delivery for implantable devices in animals is highly desired for safe and effective experimental use. Batteries require frequent replacement; wired connections are inconvenient and unsafe, and short-distance inductive coupling requires the attachment of an exterior transmitter to the animal's body. In this article, we propose a solution by which animals with implantable devices can move freely without attachments. Power is transmitted using coils attached to the animal's cage and is received by a receiver coil implanted in the animal. For a three-dimensionally uniform delivery of power, we designed a columnar dual-transmitter coil configuration. A resonator-based inductive link was adopted for efficient long-range power delivery, and we used a novel biocompatible liquid crystal polymer substrate as the implantable receiver device. Using this wireless power delivery system, we obtain an average power transfer efficiency of 15.2% (minimum efficiency of 10% and a standard deviation of 2.6) within a cage of 15×20×15 cm3.
Switchable Polymer Based Thin Film Coils as a Power Module for Wireless Neural Interfaces.
Kim, S; Zoschke, K; Klein, M; Black, D; Buschick, K; Toepper, M; Tathireddy, P; Harrison, R; Solzbacher, F
2007-05-01
Reliable chronic operation of implantable medical devices such as the Utah Electrode Array (UEA) for neural interface requires elimination of transcutaneous wire connections for signal processing, powering and communication of the device. A wireless power source that allows integration with the UEA is therefore necessary. While (rechargeable) micro batteries as well as biological micro fuel cells are yet far from meeting the power density and lifetime requirements of an implantable neural interface device, inductive coupling between two coils is a promising approach to power such a device with highly restricted dimensions. The power receiving coils presented in this paper were designed to maximize the inductance and quality factor of the coils and microfabricated using polymer based thin film technologies. A flexible configuration of stacked thin film coils allows parallel and serial switching, thereby allowing to tune the coil's resonance frequency. The electrical properties of the fabricated coils were characterized and their power transmission performance was investigated in laboratory condition.
NASA Astrophysics Data System (ADS)
Li, Hao; Liu, Jianshe; Zhang, Yingshan; Cai, Han; Li, Gang; Liu, Qichun; Han, Siyuan; Chen, Wei
2017-03-01
A negative-inductance superconducting quantum interference device (nSQUID) is an adiabatic superconducting logic device with high energy efficiency, and therefore a promising building block for large-scale low-power superconducting computing. However, the principle of the nSQUID is not that straightforward and an nSQUID driven by voltage is vulnerable to common mode noise. We investigate a single nSQUID driven by current instead of voltage, and clarify the principle of the adiabatic transition of the current-driven nSQUID between different states. The basic logic operations of the current-driven nSQUID with proper parameters are simulated by WRspice. The corresponding circuit is fabricated with a 100 A cm-2 Nb-based lift-off process, and the experimental results at low temperature confirm the basic logic operations as a gated buffer.
Low profile, highly configurable, current sharing paralleled wide band gap power device power module
McPherson, Brice; Killeen, Peter D.; Lostetter, Alex; Shaw, Robert; Passmore, Brandon; Hornberger, Jared; Berry, Tony M
2016-08-23
A power module with multiple equalized parallel power paths supporting multiple parallel bare die power devices constructed with low inductance equalized current paths for even current sharing and clean switching events. Wide low profile power contacts provide low inductance, short current paths, and large conductor cross section area provides for massive current carrying. An internal gate & source kelvin interconnection substrate is provided with individual ballast resistors and simple bolted construction. Gate drive connectors are provided on either left or right size of the module. The module is configurable as half bridge, full bridge, common source, and common drain topologies.
Stevens, R B; Wrenshall, L E; Miles, C D; Farney, A C; Jie, T; Sandoz, J P; Rigley, T H; Osama Gaber, A
2016-06-01
A previous nonblinded, randomized, single-center renal transplantation trial of single-dose rabbit anti-thymocyte globulin induction (SD-rATG) showed improved efficacy compared with conventional divided-dose (DD-rATG) administration. The present multicenter, double-blind/double-dummy STAT trial (Single dose vs. Traditional Administration of Thymoglobulin) evaluated SD-rATG versus DD-rATG induction for noninferiority in early (7-day) safety and tolerability. Ninety-five patients (randomized 1:1) received 6 mg/kg SD-rATG or 1.5 mg/kg/dose DD-rATG, with tacrolimus-mycophenolate maintenance immunosuppression. The primary end point was a composite of fever, hypoxia, hypotension, cardiac complications, and delayed graft function. Secondary end points included 12-month patient survival, graft survival, and rejection. Target enrollment was 165 patients with an interim analysis scheduled after 80 patients. Interim analysis showed primary end point noninferiority of SD-rATG induction (p = 0.6), and a conditional probability of <1.73% of continued enrollment producing a significant difference (futility analysis), leading to early trial termination. Final analysis (95 patients) showed no differences in occurrence of primary end point events (p = 0.58) or patients with no, one, or more than one event (p = 0.81), or rejection, graft, or patient survival (p = 0.78, 0.47, and 0.35, respectively). In this rigorously blinded trial in adult renal transplantation, we have shown SD-rATG induction to be noninferior to DD-rATG induction in early tolerability and equivalent in 12-month safety. (Clinical Trials.gov #NCT00906204.). © Copyright 2016 The Authors. American Journal of Transplantation published by Wiley Periodicals, Inc. on behalf of the American Society of Transplantation and the American Society of Transplant Surgeons.
Multimode and multistate ladder oscillator and frequency recognition device
NASA Technical Reports Server (NTRS)
Aumann, Herbert M. (Inventor)
1976-01-01
A ladder oscillator composed of capacitive and inductive impedances connected together to form a ladder network which has a chosen number N oscillation modes at N different frequencies. Each oscillation mode is characterized by a unique standing wave voltage pattern along the nodes of the ladder oscillator, with the mode in which the ladder oscillator is oscillating being determinable from the amplitudes or phase of the oscillations at the nodes. A logic circuit may be connected to the nodes of the oscillator to compare the phases of selected nodes and thereby determine which mode the oscillator is oscillating in. A ladder oscillator composed of passive capacitive and inductive impedances can be utilized as a frequency recognition device, since the passive ladder oscillator will display the characteristic standing wave patterns if an input signal impressed upon the ladder oscillator is close to one of the mode frequencies of the oscillator. A CL ladder oscillator having series capacitive impedances and shunt inductive impedances can exhibit sustained and autonomous oscillations if active nonlinear devices are connected in parallel with the shunt inductive impedances. The active CL ladder oscillator can be synchronized to input frequencies impressed upon the oscillator, and will continue to oscillate after the input signal has been removed at a mode frequency which is, in general, nearest to the input signal frequency. Autonomous oscillations may also be obtained as desired from the active CL ladder oscillator at the mode frequencies.
ERIC Educational Resources Information Center
Kynigos, Chronis
1993-01-01
Used 2 12-year-old children to investigate deductive and inductive reasoning in plane geometry. A LOGO microworld was programmed to measure distances and turns relative to points on the plane. Learning environments like this may enhance formation of inductive geometrical understandings. (Contains 44 references.) (LDR)
49 CFR 236.562 - Minimum rail current required.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Locomotives § 236.562 Minimum... continuous inductive automatic train stop or train control device to normal condition or to obtain a proceed...
49 CFR 236.562 - Minimum rail current required.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Locomotives § 236.562 Minimum... continuous inductive automatic train stop or train control device to normal condition or to obtain a proceed...
NASA Astrophysics Data System (ADS)
Honma, H.; Mitsuya, H.; Hashiguchi, G.; Fujita, H.; Toshiyoshi, H.
2018-06-01
We introduce symmetric comb-electrode structures for the electrostatic vibrational MEMS energy harvester to lower the electrostatic constraint force attributed to the built-in electret potential, thereby allowing the harvester device to operate in a small acceleration range of 0.05 g or lower (1 g = 9.8 m s‑2). Given the same device structure, two different potentials for the electret are tested to experimentally confirm that the output induction current is enhanced 4.2 times by increasing the electret potential from ‑60 V to ‑250 V. At the same time, the harvester effectiveness has been improved to as high as 93%. The device is used to swiftly charge a 470 µF storage capacitor to 3.3 V in 120 s from small sinusoidal vibrations of 0.6 g at 124 Hz.
Is there a relationship between curvature and inductance in the Josephson junction?
NASA Astrophysics Data System (ADS)
Dobrowolski, T.; Jarmoliński, A.
2018-03-01
A Josephson junction is a device made of two superconducting electrodes separated by a very thin layer of isolator or normal metal. This relatively simple device has found a variety of technical applications in the form of Superconducting Quantum Interference Devices (SQUIDs) and Single Electron Transistors (SETs). One can expect that in the near future the Josephson junction will find applications in digital electronics technology RSFQ (Rapid Single Flux Quantum) and in the more distant future in construction of quantum computers. Here we concentrate on the relation of the curvature of the Josephson junction with its inductance. We apply a simple Capacitively Shunted Junction (CSJ) model in order to find condition which guarantees consistency of this model with prediction based on the Maxwell and London equations with Landau-Ginzburg current of Cooper pairs. This condition can find direct experimental verification.
ERIC Educational Resources Information Center
Resing, Wilma C. M.; Touw, Kirsten W. J.; Veerbeek, Jochanan; Elliott, Julian G.
2017-01-01
This study investigated potential differences in inductive behavioural and verbal strategy-use between children (aged 6-8 years) from indigenous and non-indigenous backgrounds. This was effected by the use of an electronic device that could present a series of tasks, offer scaffolded assistance and record children's responses. Children from…
Atherton, D L; Davies, R
1979-10-01
Transformer-rectifier flux pumps using thermally switched Nb(3)Sn cryotrons are being investigated as a loss make-up device for the proposed isochorically operated (sealed) superconducting magnets for the Canadian Maglev vehicle. High currents (1000 A) were obtained in an experimental flux pump using inductive current transfer and operating at 2 Hz.
Treviso, Felipe; Silveira, Marilia A.; Flores Filho, Aly F.; Dorrell, David G.
2016-01-01
This paper presents a study on an induction planar actuator concept. The device uses the same principles as a linear induction motor in which the interaction between a travelling magnetic field and a conducting surface produces eddy currents that leads to the generation of a thrust force and can result in movement over a metallic surface. This can benefit the inspection of metallic surfaces based on the driving platform provided by the induction planar actuator. Equations of the magnetic and electric fields are presented and, by means of these equations, the forces involved were calculated. The behaviour of thrust and normal forces was analysed through the equations and by numerical models, and compared with the results obtained by measurements on a device prototype built in the laboratory as part of the study. With relation to the surface under inspection that forms the secondary, three cases were analysed: (1) a double-layered secondary formed by aluminium and ferromagnetic slabs; (2) a single aluminium layer and (3) a single ferromagnetic layer. Theoretical and measured values of thrust and normal forces showed good correlation. PMID:27007377
Induction heating coupler and annealer
NASA Technical Reports Server (NTRS)
Fox, Robert L. (Inventor); Johnson, Samuel D. (Inventor); Copeland, Carl E. (Inventor); Coultrip, Robert H. (Inventor); Phillips, W. Morris (Inventor); Johnston, David F. (Inventor); Swaim, Robert J. (Inventor); Dinkins, James R. (Inventor)
1994-01-01
An induction heating device includes a handle having a hollow interior and two opposite ends, a wrist connected to one end of the handle, a U-shaped pole piece having- two spaced apart ends, a tank circuit including an induction coil wrapped around the pole piece and a capacitor connected to the induction coil, a head connected to the wrist and including a housing for receiving the U-shaped pole piece, the two spaced apart ends of the pole piece extending outwardly beyond the housing, and a power source connected to the tank circuit. When the tank circuit is energized and a susceptor is placed in juxtaposition to the ends of the U-shaped pole piece, the susceptor is heated by induction heating due to a magnetic flux passing between the two ends of the pole piece.
NASA Technical Reports Server (NTRS)
Fox, Robert L. (Inventor); Copeland, Carl E. (Inventor); Swaim, Robert J. (Inventor); Coultrip, Robert H. (Inventor); Johnston, David F. (Inventor); Phillips, W. Morris (Inventor); Johnson, Samuel D. (Inventor); Dinkins, James R. (Inventor); Buckley, John D. (Inventor)
1994-01-01
An induction heating device includes a handle having a hollow interior and two opposite ends, a wrist connected to one end of the handle, a U-shaped pole piece having two spaced apart ends, a tank circuit including an induction coil wrapped around the pole piece and a capacitor connected to the induction coil, a head connected to the wrist and including a housing for receiving the U-shaped pole piece, the two spaced apart ends of the pole piece extending outwardely beyond the housing, and a power source connected to the tank circuit. When the tank circuit is energized and a susceptor is placed in juxtaposition to the ends of the U-shaped pole piece, the susceptor is heated by induction heating due to magnetic flux passing between the two ends of the pole piece.
A Sub-millimeter, Inductively Powered Neural Stimulator
Freeman, Daniel K.; O'Brien, Jonathan M.; Kumar, Parshant; Daniels, Brian; Irion, Reed A.; Shraytah, Louis; Ingersoll, Brett K.; Magyar, Andrew P.; Czarnecki, Andrew; Wheeler, Jesse; Coppeta, Jonathan R.; Abban, Michael P.; Gatzke, Ronald; Fried, Shelley I.; Lee, Seung Woo; Duwel, Amy E.; Bernstein, Jonathan J.; Widge, Alik S.; Hernandez-Reynoso, Ana; Kanneganti, Aswini; Romero-Ortega, Mario I.; Cogan, Stuart F.
2017-01-01
Wireless neural stimulators are being developed to address problems associated with traditional lead-based implants. However, designing wireless stimulators on the sub-millimeter scale (<1 mm3) is challenging. As device size shrinks, it becomes difficult to deliver sufficient wireless power to operate the device. Here, we present a sub-millimeter, inductively powered neural stimulator consisting only of a coil to receive power, a capacitor to tune the resonant frequency of the receiver, and a diode to rectify the radio-frequency signal to produce neural excitation. By replacing any complex receiver circuitry with a simple rectifier, we have reduced the required voltage levels that are needed to operate the device from 0.5 to 1 V (e.g., for CMOS) to ~0.25–0.5 V. This reduced voltage allows the use of smaller receive antennas for power, resulting in a device volume of 0.3–0.5 mm3. The device was encapsulated in epoxy, and successfully passed accelerated lifetime tests in 80°C saline for 2 weeks. We demonstrate a basic proof-of-concept using stimulation with tens of microamps of current delivered to the sciatic nerve in rat to produce a motor response. PMID:29230164
NASA Astrophysics Data System (ADS)
Ohchi, Masashi; Furukawa, Tatsuya
Induction heating has found a new feasibility in domestic appliances. Its application is known as an “induction range” or an “induction heating oven”. Conventional design schemes of them have depended on the experience and insight of designers. In the paper, the authors treat it as an electromagnetic device to investigate the mechanism of power dissipation using the Finite Element Method, where an impressed voltage supply is taken account of and the constant V/f condition is imposed for the constant impressed magnetic flux. Furthermore the authors will examine how to heat an aluminum pan and discuss the optimal frequency of a power supply.
NASA Astrophysics Data System (ADS)
Leung, R. C. K.; So, R. M. C.; Tang, S. K.; Wang, X. Q.
2011-07-01
In-duct devices are commonly installed in flow ducts for various flow management purposes. The structural construction of these devices indispensably creates disruption to smooth flow through duct passages so they exist as structural discontinuities in duct flow. The presence of these discontinuities provides additional possibility of noise generation. In real practice, in-duct devices do not exist alone in any duct system. Even though each in-duct device would generate its own noise, it might be possible that these devices could be properly arranged so as to strengthen the interference between individual noise; thus giving rise to an overall reduction of noise radiation in the in-duct far field. This concept of passive noise control is investigated by considering different configurations of two structural discontinuities of simple form (i.e., a cavity) in tandem in an unconfined flow and in opposing setting within a flow duct. It is known that noise generated by a cavity in unconfined domain (unconfined cavity) is strongly dependent on flow-resonant behavior within the cavity so the interference it produces is merely aeroacoustic. The objective of the present study is to verify the concept of passive noise reduction through enhancement of aeroacoustic interference due to two cavities by considering laminar flow only. A two-dimensional approach is adopted for the direct aeroacoustic calculations using a direct numerical simulation (DNS) technique. The position and geometries of the cavities and the Mach number are varied; the resultant aeroacoustic behavior and acoustic power are calculated. The numerical results are compared with a single cavity case to highlight the effect of introducing additional cavities to the aeroacoustic problem. Resonant flow oscillations occur when two unconfined cavities are very close and the associated acoustic field is very intense with no noise reduction possible. However, for duct aeroacoustics, it is found that a 7.9 db reduction of acoustic power in the downstream side of the duct or a total reduction of ˜6 db is possible with opposing cavities having an offset of half a cavity length. In addition, the reduction is shown to be free from lock-on with trapped modes of the ducts with cavities.
5.8kV SiC PiN Diode for Switching of High-Efficiency Inductive Pulsed Plasma Thruster Circuits
NASA Technical Reports Server (NTRS)
Toftul, Alexandra; Polzin, Kurt A.; Hudgins, Jerry L.
2014-01-01
Inductive Pulsed Plasma Thruster (IPPT) pulse circuits, such as those needed to operate the Pulsed Inductive Thruster (PIT), are required to quickly switch capacitor banks operating at a period of µs while conducting current at levels on the order of at least 10 kA. [1,2] For all iterations of the PIT to date, spark gaps have been used to discharge the capacitor bank through an inductive coil. Recent availability of fast, high-power solid state switching devices makes it possible to consider the use of semiconductor switches in modern IPPTs. In addition, novel pre-ionization schemes have led to a reduction in discharge energy per pulse for electric thrusters of this type, relaxing the switching requirements for these thrusters. [3,4] Solid state switches offer the advantage of greater controllability and reliability, as well as decreased drive circuit dimensions and mass relative to spark gap switches. The use of solid state devices such as Integrated Gate Bipolar Transistors (IGBTs), Gate Turn-off Thyristors (GTOs) and Silicon-Controlled Rectifiers (SCRs) often involves the use of power diodes. These semiconductor devices may be connected antiparallel to the switch for protection from reverse current, or used to reduce power loss in a circuit by clamping off current ringing. In each case, higher circuit efficiency may be achieved by using a diode that is able to transition, or 'switch,' from the forward conducting state ('on' state) to the reverse blocking state ('off' state) in the shortest amount of time, thereby minimizing current ringing and switching losses. Silicon Carbide (SiC) PiN diodes offer significant advantages to conventional fast-switching Silicon (Si) diodes for high power and fast switching applications. A wider band gap results in a breakdown voltage 10 times that of Si, so that a SiC device may have a thinner drift region for a given blocking voltage. [5] This leads to smaller, lighter devices for high voltage applications, as well as reduced forward conduction losses, faster reverse recovery time (faster turn-off), and lower-magnitude reverse recovery current. In addition, SiC devices have lower leakage current as compared to their Si counterparts, and a high thermal conductivity, potentially allowing the former to operate at higher temperatures with a smaller, lighter heatsink (or no heatsink at all).
NASA Astrophysics Data System (ADS)
Bowen, David; Krafft, Charles; Mayergoyz, Isaak D.
2017-05-01
There is strong commercial interest in the ability to fabricate the windings of traditional miniature wire-wound inductive circuit components, such as Ethernet transformers, lithographically. For greater inductance devices, thick cores are required, making the process of embedding the ferrite material within circuit board one of few options for lithographic winding fabrication. In this paper, a non-traditional core shape, suitable for embedding in circuit board, is examined analytically and experimentally; the racetrack shape is two halves of a toroid connected by straight legs. With regard to the high inductance requirements for Ethernet applications (350μH), the racetrack transformer inductance is analytically optimized, determining the optimal physical dimensions. Two sizes of racetrack-core transformers were fabricated and measured. The measured inductance was in reasonable agreement with the analytical prediction, though large variations in material permeability are expected from the mechanical processing of the ferrite. Some of the experimental transformers were observed to satisfy the Ethernet inductance requirement.
Torque shudder protection device and method
King, Robert D.; De Doncker, Rik W. A. A.; Szczesny, Paul M.
1997-01-01
A torque shudder protection device for an induction machine includes a flux command generator for supplying a steady state flux command and a torque shudder detector for supplying a status including a negative status to indicate a lack of torque shudder and a positive status to indicate a presence of torque shudder. A flux adapter uses the steady state flux command and the status to supply a present flux command identical to the steady state flux command for a negative status and different from the steady state flux command for a positive status. A limiter can receive the present flux command, prevent the present flux command from exceeding a predetermined maximum flux command magnitude, and supply the present flux command to a field oriented controller. After determining a critical electrical excitation frequency at which a torque shudder occurs for the induction machine, a flux adjuster can monitor the electrical excitation frequency of the induction machine and adjust a flux command to prevent the monitored electrical excitation frequency from reaching the critical electrical excitation frequency.
Torque shudder protection device and method
King, R.D.; Doncker, R.W.A.A. De.; Szczesny, P.M.
1997-03-11
A torque shudder protection device for an induction machine includes a flux command generator for supplying a steady state flux command and a torque shudder detector for supplying a status including a negative status to indicate a lack of torque shudder and a positive status to indicate a presence of torque shudder. A flux adapter uses the steady state flux command and the status to supply a present flux command identical to the steady state flux command for a negative status and different from the steady state flux command for a positive status. A limiter can receive the present flux command, prevent the present flux command from exceeding a predetermined maximum flux command magnitude, and supply the present flux command to a field oriented controller. After determining a critical electrical excitation frequency at which a torque shudder occurs for the induction machine, a flux adjuster can monitor the electrical excitation frequency of the induction machine and adjust a flux command to prevent the monitored electrical excitation frequency from reaching the critical electrical excitation frequency. 5 figs.
NASA Astrophysics Data System (ADS)
Petrovic, Goran; Kilic, Tomislav; Terzic, Bozo
2009-04-01
In this paper a sensorless speed detection method of induction squirrel-cage machines is presented. This method is based on frequency determination of the stator neutral point voltage primary slot harmonic, which is dependent on rotor speed. In order to prove method in steady state and dynamic conditions the simulation and experimental study was carried out. For theoretical investigation the mathematical model of squirrel cage induction machines, which takes into consideration actual geometry and windings layout, is used. Speed-related harmonics that arise from rotor slotting are analyzed using digital signal processing and DFT algorithm with Hanning window. The performance of the method is demonstrated over a wide range of load conditions.
ERIC Educational Resources Information Center
Leroux, Mylène; Beaudoin, Charlotte; Grenier, Johanne; Turcotte, Sylvain; Rivard, Marie-Claude
2016-01-01
The growing body of literature on teacher induction barriers has revealed the need to address issues that may lead to negative consequences. Recent research points to an increased interest in teacher resilience, a concept that promotes positive adaptation to counteract these adverse outcomes. However, teacher induction and resilience may differ…
Probing the tumor microenvironment: collection and induction
NASA Astrophysics Data System (ADS)
Williams, James K.; Padgen, Michael R.; Wang, Yarong; Entenberg, David; Gertler, Frank; Condeelis, John S.; Castracane, James
2012-03-01
The Nano Intravital Device, or NANIVID, is under development as an optically transparent, implantable tool to study the tumor microenvironment. Two etched glass substrates are sealed using a thin polymer membrane to create a reservoir with a single outlet. This reservoir is loaded with a hydrogel blend that contains growth factors or other chemicals to be delivered to the tumor microenvironment. When the device is implanted in the tumor, the hydrogel will swell and release these entrapped molecules, forming a gradient. Validation of the device has been performed in vitro using epidermal growth factor (EGF) and MenaINV, a highly invasive, rat mammary adenocarcinoma cell line. In both 2-D and 3-D environments, cells migrated toward the gradient of EGF released from the device. The chorioallantoic membrane (CAM) of White Leghorn chicken eggs is being utilized to grow xenograft tumors that will be used for ex vivo cell collection. Device optimization is being performed for in vivo use as a tool to collect the invasive cell population. Preliminary cell collection experiments in vivo were performed using a mouse model of breast cancer. As a second application, the device is being explored as a delivery vehicle for chemicals that induce controlled changes in the tumor microenvironment. H2O2 was loaded in the device and generated intracellular reactive oxygen species (ROS) in cells near the device outlet. In the future, other induction targets will be explored, including hypoglycemia and the manipulation of extracellular matrix stiffness.
Wireless thin film transistor based on micro magnetic induction coupling antenna.
Jun, Byoung Ok; Lee, Gwang Jun; Kang, Jong Gu; Kim, Seunguk; Choi, Ji-Woong; Cha, Seung Nam; Sohn, Jung Inn; Jang, Jae Eun
2015-12-22
A wireless thin film transistor (TFT) structure in which a source/drain or a gate is connected directly to a micro antenna to receive or transmit signals or power can be an important building block, acting as an electrical switch, a rectifier or an amplifier, for various electronics as well as microelectronics, since it allows simple connection with other devices, unlike conventional wire connections. An amorphous indium gallium zinc oxide (α-IGZO) TFT with magnetic antenna structure was fabricated and studied for this purpose. To enhance the induction coupling efficiency while maintaining the same small antenna size, a magnetic core structure consisting of Ni and nanowires was formed under the antenna. With the micro-antenna connected to a source/drain or a gate of the TFT, working electrical signals were well controlled. The results demonstrated the device as an alternative solution to existing wire connections which cause a number of problems in various fields such as flexible/wearable devices, body implanted devices, micro/nano robots, and sensors for the 'internet of things' (IoT).
Wireless thin film transistor based on micro magnetic induction coupling antenna
Jun, Byoung Ok; Lee, Gwang Jun; Kang, Jong Gu; Kim, Seunguk; Choi, Ji-Woong; Cha, Seung Nam; Sohn, Jung Inn; Jang, Jae Eun
2015-01-01
A wireless thin film transistor (TFT) structure in which a source/drain or a gate is connected directly to a micro antenna to receive or transmit signals or power can be an important building block, acting as an electrical switch, a rectifier or an amplifier, for various electronics as well as microelectronics, since it allows simple connection with other devices, unlike conventional wire connections. An amorphous indium gallium zinc oxide (α-IGZO) TFT with magnetic antenna structure was fabricated and studied for this purpose. To enhance the induction coupling efficiency while maintaining the same small antenna size, a magnetic core structure consisting of Ni and nanowires was formed under the antenna. With the micro-antenna connected to a source/drain or a gate of the TFT, working electrical signals were well controlled. The results demonstrated the device as an alternative solution to existing wire connections which cause a number of problems in various fields such as flexible/wearable devices, body implanted devices, micro/nano robots, and sensors for the ‘internet of things’ (IoT). PMID:26691929
Ground EMI: designing the future trends in shallow depth surveying
NASA Astrophysics Data System (ADS)
Thiesson, J.; Schamper, C.; Simon, F. X.; Tabbagh, A.
2017-12-01
In theory, electromagnetic induction phenomena are driven by three fundamental properties (conductivity, susceptibility, permittivity). Since the 1930's, the developments of EMI prospecting were based on assumptions (Low frequency VS High frequency, low/high induction number). The design of the devices was focused on specific aims (diffusive/propagative, mapping/sounding) and, in the last thirty years the progressive transition from analog to numeric electronics completely enhanced the potency of measurements (multi-channeling, automatic positioning) a) as it did in model computation. In the field of metric sized devices for lower depths of investigation, the measurements have been first restricted to electrical conductivity. However, the measurement of the magnetic susceptibility proved to be possible thanks to in phase and quadrature separation, and the last developed commercially available multi-frequency and/or multi-receivers devices permit, thanks to accurate calibration, the measurements of the three properties with various geometries or frequencies simultaneously. The aims of this study is to present theoretical results in order to give hints for designing a device which can be optimal to evaluate the three properties and their frequency dependence.
Wireless thin film transistor based on micro magnetic induction coupling antenna
NASA Astrophysics Data System (ADS)
Jun, Byoung Ok; Lee, Gwang Jun; Kang, Jong Gu; Kim, Seunguk; Choi, Ji-Woong; Cha, Seung Nam; Sohn, Jung Inn; Jang, Jae Eun
2015-12-01
A wireless thin film transistor (TFT) structure in which a source/drain or a gate is connected directly to a micro antenna to receive or transmit signals or power can be an important building block, acting as an electrical switch, a rectifier or an amplifier, for various electronics as well as microelectronics, since it allows simple connection with other devices, unlike conventional wire connections. An amorphous indium gallium zinc oxide (α-IGZO) TFT with magnetic antenna structure was fabricated and studied for this purpose. To enhance the induction coupling efficiency while maintaining the same small antenna size, a magnetic core structure consisting of Ni and nanowires was formed under the antenna. With the micro-antenna connected to a source/drain or a gate of the TFT, working electrical signals were well controlled. The results demonstrated the device as an alternative solution to existing wire connections which cause a number of problems in various fields such as flexible/wearable devices, body implanted devices, micro/nano robots, and sensors for the ‘internet of things’ (IoT).
Parasitic effects in superconducting quantum interference device-based radiation comb generators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bosisio, R., E-mail: riccardo.bosisio@nano.cnr.it; NEST, Instituto Nanoscienze-CNR and Scuola Normale Superiore, I-56127 Pisa; Giazotto, F., E-mail: giazotto@sns.it
2015-12-07
We study several parasitic effects on the implementation of a Josephson radiation comb generator based on a dc superconducting quantum interference device (SQUID) driven by an external magnetic field. This system can be used as a radiation generator similarly to what is done in optics and metrology, and allows one to generate up to several hundreds of harmonics of the driving frequency. First we take into account how the assumption of a finite loop geometrical inductance and junction capacitance in each SQUID may alter the operation of the devices. Then, we estimate the effect of imperfections in the fabrication ofmore » an array of SQUIDs, which is an unavoidable source of errors in practical situations. We show that the role of the junction capacitance is, in general, negligible, whereas the geometrical inductance has a beneficial effect on the performance of the device. The errors on the areas and junction resistance asymmetries may deteriorate the performance, but their effect can be limited to a large extent by a suitable choice of fabrication parameters.« less
ERIC Educational Resources Information Center
Overduin, James; Molloy, Dana; Selway, Jim
2014-01-01
Electromagnetic induction is probably one of the most challenging subjects for students in the introductory physics sequence, especially in algebra-based courses. Yet it is at the heart of many of the devices we rely on today. To help students grasp and retain the concept, we have put together a simple and dramatic classroom demonstration that…
Cone-shaped source characteristics and inductance effect of transient electromagnetic method
NASA Astrophysics Data System (ADS)
Yang, Hai-Yan; Li, Feng-Ping; Yue, Jian-Hua; Guo, Fu-Sheng; Liu, Xu-Hua; Zhang, Hua
2017-03-01
Small multi-turn coil devices are used with the transient electromagnetic method (TEM) in areas with limited space, particularly in underground environments such as coal mines roadways and engineering tunnels, and for detecting shallow geological targets in environmental and engineering fields. However, the equipment involved has strong mutual inductance coupling, which causes a lengthy turn-offtime and a deep "blind zone". This study proposes a new transmitter device with a conical-shape source and derives the radius formula of each coil and the mutual inductance coefficient of the cone. According to primary field characteristics, results of the two fields created, calculation of the conical-shaped source in a uniform medium using theoretical analysis, and a comparison of the inductance of the new device with that of the multi-turn coil, show that inductance of the multi-turn coil is nine times greater than that of the conical source with the same equivalent magnetic moment of 926.1 A·m2. This indicates that the new source leads to a much shallower "blind zone." Furthermore, increasing the bottom radius and turn of the cone creates a larger mutual inductance but increasing the cone height results in a lower mutual inductance. Using the superposition principle, the primary and secondary magnetic fields for a conical source in a homogeneous medium are calculated; results indicate that the magnetic behavior of the cone is the same as that of the multi-turn coils, but the transient responses of the secondary field and the total field are more stronger than those of the multi-turn coils. To study the transient response characteristics using a cone-shaped source in a layered earth, a numerical filtering algorithm is then developed using the fast Hankel transform and the improved cosine transform, again using the superposition principle. During development, an average apparent resistivity inverted from the induced electromotive force using each coil is defined to represent the comprehensive resistivity of the conical source. To verify the forward calculation method, the transient responses of H type models and KH type models are calculated, and data are inverted using a "smoke ring" inversion. The results of inversion have good agreement with original models and show that the forward calculation method is effective. The results of this study provide an option for solving the problem of a deep "blind zone" and also provide a theoretical indicator for further research.
Multilevel DC Link Inverter for Brushless Permanent Magnet Motors with Very Low Inductance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Su, G.J.
2001-10-29
Due to their long effective air gaps, permanent magnet motors tend to have low inductance. The use of ironless stator structure in present high power PM motors (several tens of kWs) reduces the inductance even further (< 100 {micro}H). This low inductance imposes stringent current regulation demands for the inverter to obtain acceptable current ripple. An analysis of the current ripple for these low inductance brushless PM motors shows that a standard inverter with the most commonly used IGBT switching devices cannot meet the current regulation demands and will produce unacceptable current ripples due to the IGBT's limited switching frequency.more » This paper introduces a new multilevel dc link inverter, which can dramatically reduce the current ripple for brushless PM motor drives. The operating principle and design guidelines are included.« less
Fully non-inductive second harmonic electron cyclotron plasma ramp-up in the QUEST spherical tokamak
NASA Astrophysics Data System (ADS)
Idei, H.; Kariya, T.; Imai, T.; Mishra, K.; Onchi, T.; Watanabe, O.; Zushi, H.; Hanada, K.; Qian, J.; Ejiri, A.; Alam, M. M.; Nakamura, K.; Fujisawa, A.; Nagashima, Y.; Hasegawa, M.; Matsuoka, K.; Fukuyama, A.; Kubo, S.; Shimozuma, T.; Yoshikawa, M.; Sakamoto, M.; Kawasaki, S.; Nakashima, H.; Higashijima, A.; Ide, S.; Maekawa, T.; Takase, Y.; Toi, K.
2017-12-01
Fully non-inductive second (2nd) harmonic electron cyclotron (EC) plasma current ramp-up was demonstrated with a newlly developed 28 GHz system in the QUEST spherical tokamak. A high plasma current of 54 kA was non-inductively ramped up and sustained stably for 0.9 s with a 270 kW 28 GHz wave. A higher plasma current of 66 kA was also non-inductively achieved with a slow ramp-up of the vertical field. We have achieved a significantly higher plasma current than those achieved previously with the 2nd harmonic EC waves. This fully non-inductive 2nd harmonic EC plasma ramp-up method might be useful for future burning plasma devices and fusion reactors, in particular for operations at half magnetic field with the same EC heating equipment.
Yen, Meng-Hua; Wu, Yuan-Yi; Liu, Yi-Shiuan; Rimando, Marilyn; Ho, Jennifer Hui-Chun; Lee, Oscar Kuang-Sheng
2016-08-19
Mesenchymal stromal cells (MSCs) are multipotent and have great potential in cell therapy. Previously we reported the differentiation potential of human MSCs into hepatocytes in vitro and that these cells can rescue fulminant hepatic failure. However, the conventional static culture method neither maintains growth factors at an optimal level constantly nor removes cellular waste efficiently. In addition, not only is the duration of differentiating hepatocyte lineage cells from MSCs required to improve, but also the need for a large number of hepatocytes for cell therapy has not to date been addressed fully. The purpose of this study is to design and develop an innovative microfluidic device to overcome these shortcomings. We designed and fabricated a microfluidic device and a culture system for hepatic differentiation of MSCs using our protocol reported previously. The microfluidic device contains a large culture chamber with a stable uniform flow to allow homogeneous distribution and expansion as well as efficient induction of hepatic differentiation for MSCs. The device enables real-time observation under light microscopy and exhibits a better differentiation efficiency for MSCs compared with conventional static culture. MSCs grown in the microfluidic device showed a higher level of hepatocyte marker gene expression under hepatic induction. Functional analysis of hepatic differentiation demonstrated significantly higher urea production in the microfluidic device after 21 days of hepatic differentiation. The microfluidic device allows the generation of a large number of MSCs and induces hepatic differentiation of MSCs efficiently. The device can be adapted for scale-up production of hepatic cells from MSCs for cellular therapy.
Chapter 8: Plasma operation and control
NASA Astrophysics Data System (ADS)
ITER Physics Expert Group on Disruptions, Control, Plasma, and MHD; ITER Physics Expert Group on Energetic Particles, Heating, Current and Drive; ITER Physics Expert Group on Diagnostics; ITER Physics Basis Editors
1999-12-01
Wall conditioning of fusion devices involves removal of desorbable hydrogen isotopes and impurities from interior device surfaces to permit reliable plasma operation. Techniques used in present devices include baking, metal film gettering, deposition of thin films of low-Z material, pulse discharge cleaning, glow discharge cleaning, radio frequency discharge cleaning, and in situ limiter and divertor pumping. Although wall conditioning techniques have become increasingly sophisticated, a reactor scale facility will involve significant new challenges, including the development of techniques applicable in the presence of a magnetic field and of methods for efficient removal of tritium incorporated into co-deposited layers on plasma facing components and their support structures. The current status of various approaches is reviewed, and the implications for reactor scale devices are summarized. Creation and magnetic control of shaped and vertically unstable elongated plasmas have been mastered in many present tokamaks. The physics of equilibrium control for reactor scale plasmas will rely on the same principles, but will face additional challenges, exemplified by the ITER/FDR design. The absolute positioning of outermost flux surface and divertor strike points will have to be precise and reliable in view of the high heat fluxes at the separatrix. Long pulses will require minimal control actions, to reduce accumulation of AC losses in superconducting PF and TF coils. To this end, more complex feedback controllers are envisaged, and the experimental validation of the plasma equilibrium response models on which such controllers are designed is encouraging. Present simulation codes provide an adequate platform on which equilibrium response techniques can be validated. Burning plasmas require kinetic control in addition to traditional magnetic shape and position control. Kinetic control refers to measures controlling density, rotation and temperature in the plasma core as well as in plasma periphery and divertor. The planned diagnostics (Chapter 7) serve as sensors for kinetic control, while gas and pellet fuelling, auxiliary power and angular momentum input, impurity injection, and non-inductive current drive constitute the control actuators. For example, in an ignited plasma, core density controls fusion power output. Kinetic control algorithms vary according to the plasma state, e.g. H- or L-mode. Generally, present facilities have demonstrated the kinetic control methods required for a reactor scale device. Plasma initiation - breakdown, burnthrough and initial current ramp - in reactor scale tokamaks will not involve physics differing from that found in present day devices. For ITER, the induced electric field in the chamber will be ~0.3V· m-1 - comparable to that required by breakdown theory but somewhat smaller than in present devices. Thus, a start-up 3MW electron cyclotron heating system will be employed to assure burnthrough. Simulations show that plasma current ramp up and termination in a reactor scale device can follow procedures developed to avoid disruption in present devices. In particular, simulations remain in the stable area of the li-q plane. For design purposes, the resistive V·s consumed during initiation is found, by experiments, to follow the Ejima expression, 0.45μ0 RIp. Advanced tokamak control has two distinct goals. First, control of density, auxiliary power, and inductive current ramping to attain reverse shear q profiles and internal transport barriers, which persist until dissipated by magnetic flux diffusion. Such internal transport barriers can lead to transient ignition. Second, combined use poloidal field shape control with non-inductive current drive and NBI angular momentum injection to create and control steady state, high bootstrap fraction, reverse shear discharges. Active n = 1 magnetic feedback and/or driven rotation will be required to suppress resistive wall modes for steady state plasmas that must operate in the wall stabilized regime for reactor levels of β >= 0.03.
Properties of Superconducting Mo, Mo2n and Trilayer Mo2n-Mo-Mo2n Thin Films
NASA Technical Reports Server (NTRS)
Barrentine, E. M.; Stevenson, T. R.; Brown, A. D.; Lowitz, A. E.; Noroozian, O.; U-Yen, K.; Eshan, N.; Hsieh, W. T.; Moseley, S. H.; Wollack, E. J.
2014-01-01
We present measurements of the properties of thin film superconducting Mo, Mo2N and Mo2N/Mo/Mo2N trilayers of interest for microwave kinetic inductance detector (MKID) applications. Using microwave resonator devices, we investigate the transition temperature, energy gaps, kinetic inductance, and internal quality factors of these materials. We present an Usadel-based interpretation of the trilayer transition temperature as a function of trilayer thicknesses, and a 2-gap interpretation to understand the change in kinetic inductance and internal resonance quality factor (Q) as a function of temperature.
Electromagnetic induction imaging with a radio-frequency atomic magnetometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deans, Cameron; Marmugi, Luca, E-mail: l.marmugi@ucl.ac.uk; Hussain, Sarah
2016-03-07
We report on a compact, tunable, and scalable to large arrays imaging device, based on a radio-frequency optically pumped atomic magnetometer operating in magnetic induction tomography modality. Imaging of conductive objects is performed at room temperature, in an unshielded environment and without background subtraction. Conductivity maps of target objects exhibit not only excellent performance in terms of shape reconstruction but also demonstrate detection of sub-millimetric cracks and penetration of conductive barriers. The results presented here demonstrate the potential of a future generation of imaging instruments, which combine magnetic induction tomography and the unmatched performance of atomic magnetometers.
Studies on laws of stress-magnetization based on magnetic memory testing technique
NASA Astrophysics Data System (ADS)
Ren, Shangkun; Ren, Xianzhi
2018-03-01
Metal magnetic memory (MMM) testing technique is a novel testing method which can early test stress concentration status of ferromagnetic components. Under the different maximum tensile stress, the relationship between the leakage magnetic field of at certain point of cold rolled steel specimen and the tensile stress was measured during the process of loading and unloading by repeated. It shows that when the maximum tensile stress is less than 610 MPa, the relationship between the magnetic induction intensity and the stress is linear; When the maximum tensile stress increase from 610 MPa to 653 MPa of yield point, the relationship between the magnetic induction intensity and the tensile becomes bending line. The location of the extreme point of the bending line will move rapidly from the position of smaller stress to the larger stress position, and the variation of magnetic induction intensity increases rapidly. When the maximum tensile stress is greater than the 653 MPa of yield point, the variation of the magnetic induction intensity remains large, and the position of the extreme point moves very little. In theoretical aspects, tensile stress is to be divided into ordered stress and disordered stress. In the stage of elastic stress, a microscopic model of the order stress magnetization is established, and the conclusions are in good agreement with the experimental data. In the plastic deformation stage, a microscopic model of disordered stress magnetization is established, and the conclusions are in good agreement with the experimental data, too. The research results can provide reference for the accurate quantitative detection and evaluation of metal magnetic memory testing technology.
Design of spherical electron gun for ultra high frequency, CW power inductive output tube
NASA Astrophysics Data System (ADS)
Kaushik, Meenu; Joshi, L. M.
2016-03-01
Inductive Output Tube (IOT) is an amplifier that usually operates in UHF range. It is an electron tube whose basic structure is similar to conventional vacuum devices. This device is widely used in broadcast applications but is now being explored for scientific applications also specifically, particle accelerators and fusion plasma heating purposes. The paper describes the design approach of a spherical gridded electron gun of a 500 MHz, 100 kW CW power IOT. The electron gun structure has been simulated and optimized for operating voltage and current of 40kV and 3.5 A respectively. The electromagnetic analysis of this spherical electron gun has been carried out in CST and TRAK codes.
Modelling of resonant MEMS magnetic field sensor with electromagnetic induction sensing
NASA Astrophysics Data System (ADS)
Liu, Song; Xu, Huaying; Xu, Dehui; Xiong, Bin
2017-06-01
This paper presents an analytical model of resonant MEMS magnetic field sensor with electromagnetic induction sensing. The resonant structure vibrates in square extensional (SE) mode. By analyzing the vibration amplitude and quality factor of the resonant structure, the magnetic field sensitivity as a function of device structure parameters and encapsulation pressure is established. The developed analytical model has been verified by comparing calculated results with experiment results and the deviation between them is only 10.25%, which shows the feasibility of the proposed device model. The model can provide theoretical guidance for further design optimization of the sensor. Moreover, a quantitative study of the magnetic field sensitivity is conducted with respect to the structure parameters and encapsulation pressure based on the proposed model.
Design of spherical electron gun for ultra high frequency, CW power inductive output tube
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaushik, Meenu, E-mail: mkceeri@gmail.com; Joshi, L. M., E-mail: lmj1953@gmail.com; Academy of Scientific and Innovative Research
Inductive Output Tube (IOT) is an amplifier that usually operates in UHF range. It is an electron tube whose basic structure is similar to conventional vacuum devices. This device is widely used in broadcast applications but is now being explored for scientific applications also specifically, particle accelerators and fusion plasma heating purposes. The paper describes the design approach of a spherical gridded electron gun of a 500 MHz, 100 kW CW power IOT. The electron gun structure has been simulated and optimized for operating voltage and current of 40kV and 3.5 A respectively. The electromagnetic analysis of this spherical electron gunmore » has been carried out in CST and TRAK codes.« less
Rapid induction bonding of composites, plastics, and metals
NASA Technical Reports Server (NTRS)
Buckley, John D.; Fox, Robert L.
1991-01-01
The Toroid Bonding Gun is and induction heating device. It is a self contained, portable, low powered induction welding system developed for bonding or joining plastic, ceramic, or metallic parts. Structures can be bonded in a factory or in a the field. This type of equipment allows for applying heat directly to the bond lines and/or to the adhesives without heating the entire structure, supports, and fixtures of a bonding assembly. The induction heating gun originally developed for use in the fabrication of space Gangs of bonders are now used to rapidly join composite sheet and structural components. Other NASA-developed applications of this bonding technique include the joining of thermoplastic composites, thermosetting composites, metals, and combinations of these materials.
1982-11-30
the cost of an alternate signal set: - Power - Bidirectional data link (point-to-point) (plus store receptacle or induction coil) b. FUNCTION...digital fuzes had been implemented. The first presentation described an inductive data link for surface launched projectiles which sent both power and...AD-A130 681 MINUTES OF FSC 5935 CONNECTOR STANDARDIZATION PLANNING 1/2 MEETING HELD AT DAYTON OHIO ON 25-27 AUGUST 1982WU) DEFENSE ELECTRONICS SUPPLY
Multiphysics analysis of liquid metal annular linear induction pumps: A project overview
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maidana, Carlos Omar; Nieminen, Juha E.
Liquid metal-cooled fission reactors are both moderated and cooled by a liquid metal solution. These reactors are typically very compact and they can be used in regular electric power production, for naval and space propulsion systems or in fission surface power systems for planetary exploration. The coupling between the electromagnetics and thermo-fluid mechanical phenomena observed in liquid metal thermo-magnetic systems for nuclear and space applications gives rise to complex engineering magnetohydrodynamics and numerical problems. It is known that electromagnetic pumps have a number of advantages over rotating mechanisms: absence of moving parts, low noise and vibration level, simplicity of flowmore » rate regulation, easy maintenance and so on. However, while developing annular linear induction pumps, we are faced with a significant problem of magnetohydrodynamic instability arising in the device. The complex flow behavior in this type of devices includes a time-varying Lorentz force and pressure pulsation due to the time-varying electromagnetic fields and the induced convective currents that originates from the liquid metal flow, leading to instability problems along the device geometry. The determinations of the geometry and electrical configuration of liquid metal thermo-magnetic devices give rise to a complex inverse magnetohydrodynamic field problem were techniques for global optimization should be used, magnetohydrodynamics instabilities understood –or quantified- and multiphysics models developed and analyzed. Lastly, we present a project overview as well as a few computational models developed to study liquid metal annular linear induction pumps using first principles and the a few results of our multi-physics analysis.« less
Multiphysics analysis of liquid metal annular linear induction pumps: A project overview
Maidana, Carlos Omar; Nieminen, Juha E.
2016-03-14
Liquid metal-cooled fission reactors are both moderated and cooled by a liquid metal solution. These reactors are typically very compact and they can be used in regular electric power production, for naval and space propulsion systems or in fission surface power systems for planetary exploration. The coupling between the electromagnetics and thermo-fluid mechanical phenomena observed in liquid metal thermo-magnetic systems for nuclear and space applications gives rise to complex engineering magnetohydrodynamics and numerical problems. It is known that electromagnetic pumps have a number of advantages over rotating mechanisms: absence of moving parts, low noise and vibration level, simplicity of flowmore » rate regulation, easy maintenance and so on. However, while developing annular linear induction pumps, we are faced with a significant problem of magnetohydrodynamic instability arising in the device. The complex flow behavior in this type of devices includes a time-varying Lorentz force and pressure pulsation due to the time-varying electromagnetic fields and the induced convective currents that originates from the liquid metal flow, leading to instability problems along the device geometry. The determinations of the geometry and electrical configuration of liquid metal thermo-magnetic devices give rise to a complex inverse magnetohydrodynamic field problem were techniques for global optimization should be used, magnetohydrodynamics instabilities understood –or quantified- and multiphysics models developed and analyzed. Lastly, we present a project overview as well as a few computational models developed to study liquid metal annular linear induction pumps using first principles and the a few results of our multi-physics analysis.« less
A Review of Assistive Listening Device and Digital Wireless Technology for Hearing Instruments
Kim, Chun Hyeok
2014-01-01
Assistive listening devices (ALDs) refer to various types of amplification equipment designed to improve the communication of individuals with hard of hearing to enhance the accessibility to speech signal when individual hearing instruments are not sufficient. There are many types of ALDs to overcome a triangle of speech to noise ratio (SNR) problems, noise, distance, and reverberation. ALDs vary in their internal electronic mechanisms ranging from simple hard-wire microphone-amplifier units to more sophisticated broadcasting systems. They usually use microphones to capture an audio source and broadcast it wirelessly over a frequency modulation (FM), infra-red, induction loop, or other transmission techniques. The seven types of ALDs are introduced including hardwire devices, FM sound system, infra-red sound system, induction loop system, telephone listening devices, television, and alert/alarm system. Further development of digital wireless technology in hearing instruments will make possible direct communication with ALDs without any accessories in the near future. There are two technology solutions for digital wireless hearing instruments improving SNR and convenience. One is near-field magnetic induction combined with Bluetooth radio frequency (RF) transmission or proprietary RF transmission and the other is proprietary RF transmission alone. Recently launched digital wireless hearing aid applying this new technology can communicate from the hearing instrument to personal computer, phones, Wi-Fi, alert systems, and ALDs via iPhone, iPad, and iPod. However, it comes with its own iOS application offering a range of features but there is no option for Android users as of this moment. PMID:25566400
Ivanoff, Chris S; Wu, Jie Jayne; Mirzajani, Hadi; Cheng, Cheng; Yuan, Quan; Kevorkyan, Stepan; Gaydarova, Radostina; Tomlekova, Desislava
2016-10-01
AC electrokinetics (ACEK) has been shown to deliver certain drugs into human teeth more effectively than diffusion. However, using electrical wires to power intraoral ACEK devices poses risks to patients. The study demonstrates a novel interdigitated electrode arrays (IDE) assembly powered by inductive coupling to induce ACEK effects at appropriate frequencies to motivate drugs wirelessly. A signal generator produces the modulating signal, which multiplies with the carrier signal to produce the amplitude modulated (AM) signal. The AM signal goes through the inductive link to appear on the secondary coil, then rectified and filtered to dispose of its carrier signal, and the positive half of the modulating signal appears on the load. After characterizing the device, the device is validated under light microscopy by motivating carboxylate-modified microspheres, tetracycline, acetaminophen, benzocaine, lidocaine and carbamide peroxide particles with induced ACEK effects. The assembly is finally tested in a common dental bleaching application. After applying 35 % carbamide peroxide to human teeth topically or with the IDE at 1200 Hz, 5 Vpp for 20 min, spectrophotometric analysis showed that compared to diffusion, the IDE enhanced whitening in specular optic and specular optic excluded modes by 215 % and 194 % respectively. Carbamide peroxide absorbance by the ACEK group was two times greater than diffusion as measured by colorimetric oxidation-reduction and UV-Vis spectroscopy at 550 nm. The device motivates drugs of variable molecular weight and structure wirelessly. Wireless transport of drugs to intraoral targets under ACEK effects may potentially improve the efficacy and safety of drug delivery in dentistry.
A review of assistive listening device and digital wireless technology for hearing instruments.
Kim, Jin Sook; Kim, Chun Hyeok
2014-12-01
Assistive listening devices (ALDs) refer to various types of amplification equipment designed to improve the communication of individuals with hard of hearing to enhance the accessibility to speech signal when individual hearing instruments are not sufficient. There are many types of ALDs to overcome a triangle of speech to noise ratio (SNR) problems, noise, distance, and reverberation. ALDs vary in their internal electronic mechanisms ranging from simple hard-wire microphone-amplifier units to more sophisticated broadcasting systems. They usually use microphones to capture an audio source and broadcast it wirelessly over a frequency modulation (FM), infra-red, induction loop, or other transmission techniques. The seven types of ALDs are introduced including hardwire devices, FM sound system, infra-red sound system, induction loop system, telephone listening devices, television, and alert/alarm system. Further development of digital wireless technology in hearing instruments will make possible direct communication with ALDs without any accessories in the near future. There are two technology solutions for digital wireless hearing instruments improving SNR and convenience. One is near-field magnetic induction combined with Bluetooth radio frequency (RF) transmission or proprietary RF transmission and the other is proprietary RF transmission alone. Recently launched digital wireless hearing aid applying this new technology can communicate from the hearing instrument to personal computer, phones, Wi-Fi, alert systems, and ALDs via iPhone, iPad, and iPod. However, it comes with its own iOS application offering a range of features but there is no option for Android users as of this moment.
NASA Astrophysics Data System (ADS)
Frolov, Vladimir; Backhaus, Scott; Chertkov, Misha
2014-10-01
We explore optimization methods for planning the placement, sizing and operations of flexible alternating current transmission system (FACTS) devices installed to relieve transmission grid congestion. We limit our selection of FACTS devices to series compensation (SC) devices that can be represented by modification of the inductance of transmission lines. Our master optimization problem minimizes the l1 norm of the inductance modification subject to the usual line thermal-limit constraints. We develop heuristics that reduce this non-convex optimization to a succession of linear programs (LP) that are accelerated further using cutting plane methods. The algorithm solves an instance of the MatPower Polish Grid model (3299 lines and 2746 nodes) in 40 seconds per iteration on a standard laptop—a speed that allows the sizing and placement of a family of SC devices to correct a large set of anticipated congestions. We observe that our algorithm finds feasible solutions that are always sparse, i.e., SC devices are placed on only a few lines. In a companion manuscript, we demonstrate our approach on realistically sized networks that suffer congestion from a range of causes, including generator retirement. In this manuscript, we focus on the development of our approach, investigate its structure on a small test system subject to congestion from uniform load growth, and demonstrate computational efficiency on a realistically sized network.
Frolov, Vladimir; Backhaus, Scott; Chertkov, Misha
2014-10-24
We explore optimization methods for planning the placement, sizing and operations of Flexible Alternating Current Transmission System (FACTS) devices installed to relieve transmission grid congestion. We limit our selection of FACTS devices to Series Compensation (SC) devices that can be represented by modification of the inductance of transmission lines. Our master optimization problem minimizes the l 1 norm of the inductance modification subject to the usual line thermal-limit constraints. We develop heuristics that reduce this non-convex optimization to a succession of Linear Programs (LP) which are accelerated further using cutting plane methods. The algorithm solves an instance of the MatPowermore » Polish Grid model (3299 lines and 2746 nodes) in 40 seconds per iteration on a standard laptop—a speed up that allows the sizing and placement of a family of SC devices to correct a large set of anticipated congestions. We observe that our algorithm finds feasible solutions that are always sparse, i.e., SC devices are placed on only a few lines. In a companion manuscript, we demonstrate our approach on realistically-sized networks that suffer congestion from a range of causes including generator retirement. In this manuscript, we focus on the development of our approach, investigate its structure on a small test system subject to congestion from uniform load growth, and demonstrate computational efficiency on a realistically-sized network.« less
Storing quantum information in spins and high-sensitivity ESR
NASA Astrophysics Data System (ADS)
Morton, John J. L.; Bertet, Patrice
2018-02-01
Quantum information, encoded within the states of quantum systems, represents a novel and rich form of information which has inspired new types of computers and communications systems. Many diverse electron spin systems have been studied with a view to storing quantum information, including molecular radicals, point defects and impurities in inorganic systems, and quantum dots in semiconductor devices. In these systems, spin coherence times can exceed seconds, single spins can be addressed through electrical and optical methods, and new spin systems with advantageous properties continue to be identified. Spin ensembles strongly coupled to microwave resonators can, in principle, be used to store the coherent states of single microwave photons, enabling so-called microwave quantum memories. We discuss key requirements in realising such memories, including considerations for superconducting resonators whose frequency can be tuned onto resonance with the spins. Finally, progress towards microwave quantum memories and other developments in the field of superconducting quantum devices are being used to push the limits of sensitivity of inductively-detected electron spin resonance. The state-of-the-art currently stands at around 65 spins per √{ Hz } , with prospects to scale down to even fewer spins.
Storing quantum information in spins and high-sensitivity ESR.
Morton, John J L; Bertet, Patrice
2018-02-01
Quantum information, encoded within the states of quantum systems, represents a novel and rich form of information which has inspired new types of computers and communications systems. Many diverse electron spin systems have been studied with a view to storing quantum information, including molecular radicals, point defects and impurities in inorganic systems, and quantum dots in semiconductor devices. In these systems, spin coherence times can exceed seconds, single spins can be addressed through electrical and optical methods, and new spin systems with advantageous properties continue to be identified. Spin ensembles strongly coupled to microwave resonators can, in principle, be used to store the coherent states of single microwave photons, enabling so-called microwave quantum memories. We discuss key requirements in realising such memories, including considerations for superconducting resonators whose frequency can be tuned onto resonance with the spins. Finally, progress towards microwave quantum memories and other developments in the field of superconducting quantum devices are being used to push the limits of sensitivity of inductively-detected electron spin resonance. The state-of-the-art currently stands at around 65 spins per Hz, with prospects to scale down to even fewer spins. Copyright © 2017. Published by Elsevier Inc.
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Sivak, Amy D.; Balla, Joseph V.
2011-01-01
Pulsed inductive plasma accelerators are electrodeless space propulsion devices where a capacitor is charged to an initial voltage and then discharged through a coil as a high-current pulse that inductively couples energy into the propellant. The field produced by this pulse ionizes the propellant, producing a plasma near the face of the coil. Once a plasma is formed if can be accelerated and expelled at a high exhaust velocity by the Lorentz force arising from the interaction of an induced plasma current and the magnetic field. While there are many coil geometries that can be employed to inductively accelerate a plasma, in this paper the discussion is limit to planar geometries where the coil take the shape of a flat spiral. A recent review of the developmental history of planar-geometry pulsed inductive thrusters can be found in Ref. [1]. Two concepts that have employed this geometry are the Pulsed Inductive Thruster (PIT) and the Faraday Accelerator with Radio-frequency Assisted Discharge (FARAD).
Operational Characteristics and Plasma Measurements in a Low-Energy FARAD Thruster
NASA Technical Reports Server (NTRS)
Polzin, K. A.; Best, S.; Rose, M. F.; Miller, R.; Owens, T.
2008-01-01
Pulsed inductive plasma accelerators are spacecraft propulsion devices in which energy is stored in a capacitor and then discharged through an inductive coil. The device is electrodeless, inducing a plasma current sheet in propellant located near the face of the coil. The propellant is accelerated and expelled at a high exhaust velocity (order of 10 km/s) through the interaction of the plasma current with an induced magnetic field. The Faraday Accelerator with RF-Assisted Discharge (FARAD) thruster is a type of pulsed inductive plasma accelerator in which the plasma is preionized by a mechanism separate from that used to form the current sheet and accelerate the gas. Employing a separate preionization mechanism in this manner allows for the formation of an inductive current sheet at much lower discharge energies and voltages than those found in previous pulsed inductive accelerators like the Pulsed Inductive Thruster (PIT). In this paper, we present measurements aimed at quantifying the thruster's overall operational characteristics and providing additional insight into the nature of operation. Measurements of the terminal current and voltage characteristics during the pulse help quantify the output of the pulsed power train driving the acceleration coil. A fast ionization gauge is used to measure the evolution of the neutral gas distribution in the accelerator prior to a pulse. The preionization process is diagnosed by monitoring light emission from the gas using a photodiode, and a time-resolved global view of the evolving, accelerating current sheet is obtained using a fast-framing camera. Local plasma and field measurements are obtained using an array of intrusive probes. The local induced magnetic field and azimuthal current density are measured using B-dot probes and mini-Rogowski coils, respectively. Direct probing of the number density and electron temperature is performed using a triple probe.
Fabrication and Characterization of Superconducting Resonators
Cataldo, Giuseppe; Barrentine, Emily M.; Brown, Ari D.; Moseley, Samuel H.; U-Yen, Kongpop; Wollack, Edward J.
2016-01-01
Superconducting microwave resonators are of interest for a wide range of applications, including for their use as microwave kinetic inductance detectors (MKIDs) for the detection of faint astrophysical signatures, as well as for quantum computing applications and materials characterization. In this paper, procedures are presented for the fabrication and characterization of thin-film superconducting microwave resonators. The fabrication methodology allows for the realization of superconducting transmission-line resonators with features on both sides of an atomically smooth single-crystal silicon dielectric. This work describes the procedure for the installation of resonator devices into a cryogenic microwave testbed and for cool-down below the superconducting transition temperature. The set-up of the cryogenic microwave testbed allows one to do careful measurements of the complex microwave transmission of these resonator devices, enabling the extraction of the properties of the superconducting lines and dielectric substrate (e.g., internal quality factors, loss and kinetic inductance fractions), which are important for device design and performance. PMID:27284966
Dantsker, Eugene; Clarke, John
2000-01-01
The present invention comprises a high-transition-temperature superconducting device having low-magnitude low-frequency noise-characteristics in magnetic fields comprising superconducting films wherein the films have a width that is less than or equal to a critical width, w.sub.C, which depends on an ambient magnetic field. For operation in the Earth's magnetic field, the critical width is about 6 micrometers (.mu.m). When made with film widths of about 4 .mu.m an inventive high transition-temperature, superconducting quantum interference device (SQUID) excluded magnetic flux vortices up to a threshold ambient magnetic field of about 100 microTesla (.mu.T). SQUIDs were fabricated having several different film strip patterns. When the film strip width was kept at about 4 .mu.m, the SQUIDs exhibited essentially no increase in low-frequency noise, even when cooled in static magnetic fields of magnitude up to 100 .mu.T. Furthermore, the mutual inductance between the inventive devices and a seven-turn spiral coil was at least 85% of that for inductive coupling to a conventional SQUID.
A 350 MHz, 200 kW CW, Multiple Beam Inductive Output Tube - Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
R.Lawrece Ives; George Collins; David Marsden Michael Read
2012-11-28
This program developed a 200 kW CW, 350 MHz, multiple beam inductive output tube (MBIOT) for driving accelerator cavities. The MBIOT operates at 30 kV with a gain of 23 dB. The estimated efficiency is 70%. The device uses seven electron beams, each transmitting 1.4 A of current. The tube is approximately six feet long and weighs approximately 400 lbs. The prototype device will be evaluated as a potential RF source for the Advanced Photon Source at Argonne National Laboratory (ANL). Because of issues related to delivery of the electron guns, it was not possible to complete assembly and testmore » of the MBIOT during the Phase II program. The device is being completed with support from Calabazas Creek Research, Inc., Communications & Power Industries, LLC. and the Naval Surface Weapons Center (NSWC) in Dahlgren, VA. The MBIOT will be initially tested at NSWC before delivery to ANL. The testing at NSWC is scheduled for February 2013.« less
Design and Testing of a Small Inductive Pulsed Plasma Thruster
NASA Technical Reports Server (NTRS)
Martin, Adam K.; Dominguez, Alexandra; Eskridge, Richard H.; Polzin, Kurt A.; Riley, Daniel P.; Perdue, Kevin A.
2015-01-01
The design and testing of a small inductive pulsed plasma thruster (IPPT) is described. The device was built as a test-bed for the pulsed gas-valves and solid-state switches required for a thruster of this kind, and was designed to be modular to facilitate modification. The thruster in its present configuration consists of a multi-turn, spiral-wound acceleration coil (270 millimeters outer diameter, 100 millimeters inner diameter) driven by a 10 microfarad capacitor and switched with a high-voltage thyristor, a propellant delivery system including a fast pulsed gas-valve, and a glow-discharge pre-ionizer circuit. The acceleration coil circuit may be operated at voltages up to 4 kilovolts (the thyristor limit is 4.5 kilovolts) and the thruster operated at cyclic-rates up to 30 Herz. Initial testing of the thruster, both bench-top and in-vacuum, has been performed. Cyclic operation of the complete device was demonstrated (at 2 Herz), and a number of valuable insights pertaining to the design of these devices have been gained.
125Mbps ultra-wideband system evaluation for cortical implant devices.
Luo, Yi; Winstead, Chris; Chiang, Patrick
2012-01-01
This paper evaluates the performance of a 125Mbps Impulse Ratio Ultra-Wideband (IR-UWB) system for cortical implant devices by using low-Q inductive coil link operating in the near-field domain. We examine design tradeoffs between transmitted signal amplitude, reliability, noise and clock jitter. The IR-UWB system is modeled using measured parameters from a reported UWB transceiver implemented in 90nm-CMOS technology. Non-optimized inductive coupling coils with low-Q value for near-field data transmission are modeled in order to build a full channel from the transmitter (Tx) to the receiver (Rx). On-off keying (OOK) modulation is used together with a low-complexity convolutional error correcting code. The simulation results show that even though the low-Q coils decrease the amplitude of the received pulses, the UWB system can still achieve acceptable performance when error correction is used. These results predict that UWB is a good candidate for delivering high data rates in cortical implant devices.
Langhoff, Rebecca; Auer, Ulrike; Maneng, Julia; Hochgerner, Agnes; Ritzmann, Mathias
2016-01-01
The aim of this study was to describe clinical and behavioural parameters of piglets castrated with the use of CO2 anaesthesia by using the commercial available device MS Pigsleeper. 80 male piglets with three to six days of age were allocated to four groups, and were castrated or left uncastrated either after receiving 70% CO2/30% O02, or without anaesthesia. Defensive movements and heart rates were measured during induction and castration phase. At castration phase the dewclaw reflex was tested and piglets were monitored for vocalisation. During recovery and the subsequent five minutes conspicuous behaviours were recorded. Intensity of defensive movements was significantly higher in groups with CO2 anaesthesia during induction phase. Defensive movements were significantly lower in groups with CO2, but also not fully absent, during castration phase. Surgical tolerance was only reached by 20% (4/20) of piglets castrated under anaesthesia. Heart rates were above physiological levels at the beginning of induction phase and dropped significantly thereafter. Dropping of heart rates was more pronounced in anaesthetised groups leading to significant differences compared to non-anaesthetised groups. A minimum heart rate of 20 beats per minute was measured. Conspicuous behaviours as spasms, gasping and licking were described for pigs after CO2 anaesthesia. Measured parameters implicated stress and discomfort during induction and recovery phase and severe cardiovascular depression during CO2 anaesthesia. Surgical tolerance was reached by only a small proportion of anaesthetised piglets. Therefore, welfare aspects were not met using CO2 anaesthesia for piglet castration in general and especially by applying the gas anaesthesia with the commercial device MS Pigsleeper.
Optimal Control of Induction Machines to Minimize Transient Energy Losses
NASA Astrophysics Data System (ADS)
Plathottam, Siby Jose
Induction machines are electromechanical energy conversion devices comprised of a stator and a rotor. Torque is generated due to the interaction between the rotating magnetic field from the stator, and the current induced in the rotor conductors. Their speed and torque output can be precisely controlled by manipulating the magnitude, frequency, and phase of the three input sinusoidal voltage waveforms. Their ruggedness, low cost, and high efficiency have made them ubiquitous component of nearly every industrial application. Thus, even a small improvement in their energy efficient tend to give a large amount of electrical energy savings over the lifetime of the machine. Hence, increasing energy efficiency (reducing energy losses) in induction machines is a constrained optimization problem that has attracted attention from researchers. The energy conversion efficiency of induction machines depends on both the speed-torque operating point, as well as the input voltage waveform. It also depends on whether the machine is in the transient or steady state. Maximizing energy efficiency during steady state is a Static Optimization problem, that has been extensively studied, with commercial solutions available. On the other hand, improving energy efficiency during transients is a Dynamic Optimization problem that is sparsely studied. This dissertation exclusively focuses on improving energy efficiency during transients. This dissertation treats the transient energy loss minimization problem as an optimal control problem which consists of a dynamic model of the machine, and a cost functional. The rotor field oriented current fed model of the induction machine is selected as the dynamic model. The rotor speed and rotor d-axis flux are the state variables in the dynamic model. The stator currents referred to as d-and q-axis currents are the control inputs. A cost functional is proposed that assigns a cost to both the energy losses in the induction machine, as well as the deviations from desired speed-torque-magnetic flux setpoints. Using Pontryagin's minimum principle, a set of necessary conditions that must be satisfied by the optimal control trajectories are derived. The conditions are in the form a two-point boundary value problem, that can be solved numerically. The conjugate gradient method that was modified using the Hestenes-Stiefel formula was used to obtain the numerical solution of both the control and state trajectories. Using the distinctive shape of the numerical trajectories as inspiration, analytical expressions were derived for the state, and control trajectories. It was shown that the trajectory could be fully described by finding the solution of a one-dimensional optimization problem. The sensitivity of both the optimal trajectory and the optimal energy efficiency to different induction machine parameters were analyzed. A non-iterative solution that can use feedback for generating optimal control trajectories in real time was explored. It was found that an artificial neural network could be trained using the numerical solutions and made to emulate the optimal control trajectories with a high degree of accuracy. Hence a neural network along with a supervisory logic was implemented and used in a real-time simulation to control the Finite Element Method model of the induction machine. The results were compared with three other control regimes and the optimal control system was found to have the highest energy efficiency for the same drive cycle.
Kang, Jong-Gu; Jeong, Yeri; Shin, Jeong Hee; Choi, Ji-Woong; Sohn, Jung Inn; Cha, Seung Nam; Jang, Jae Eun
2014-11-01
For biomedical implanted devices, a wireless power or a signal transmission is essential to protect an infection and to enhance durability. In this study, we present a magnetic induction technique for a power transmission without any wire connection between transmitter (Tx) and receiver (Rx) in a micro scale. Due to a micro size effect of a flat spiral coil, a magnetic inductance is not high. To enhance the magnetic inductance, a three dimensional magnetic core is added to an antenna structure, which is consisted of ZnO nano wires coated by a nickel (Ni) layer. ZnO nano wires easily supply a large effective surface area with a vertical structural effect to the magnetic core structure, which induces a higher magnetic inductance with a ferro-magnetic material Ni. The magnetic induction antenna with the magnetic core shows a high inductance value, a low reflection power and a strong power transmission. The power transmission efficiencies are tested under the air and the water medium are almost the same values, so that the magnetic induction technique is quite proper to body implanted systems.
Aveyard, Paul; Wang, Dechao; Connock, Martin; Fry-Smith, Anne; Barton, Pelham; Moore, David
2009-05-01
A Society for Research on Nicotine and Tobacco working group recommended outcome measures for cessation-induction trials and aid-to-cessation trials. Cessation-induction trials aim to motivate unwilling quitters to make a quit attempt. Aid-to-cessation trials give either medication or behavioral interventions to increase the rate at which willing quitters succeed in their attempts. Nicotine-assisted reduction programs combine features of both types of interventions by giving nicotine replacement to unwilling quitters. Treatment can be prolonged more than a year, quit attempts can occur and succeed early or late in the program, and renewed quit attempts are an inherent part of the program. Conventional outcome measures are tied to a fixed but arbitrary point in follow-up and cannot capture the true outcome: Prolonged cessation anchored to the point at which a person makes a successful quit attempt. We propose that the outcome should be counted from the successful quit attempt that began during the treatment period and continues for a defined period, ideally 6 months. In particular, if a trial compared a short reduction program with a long reduction program, it would not be possible to obtain an unbiased assessment of the outcome of such a trial using a measure tied to a fixed point in follow-up. Floating prolonged abstinence could provide such an assessment and is suitable for either prolonged cessation-induction trial or combined cessation-induction and aid-to-cessation trials.
NASA Astrophysics Data System (ADS)
Zhang, Yu; Liu, Jinliang
2013-02-01
As important devices for voltage boosting and switching, respectively, pulse transformer and magnetic switch are widely used in pulsed power technology. In this paper, a new kind of transformer type magnetic switch (TTMS) with coaxial cylindrical conductors is put forward to combine the functions of voltage boosting and switching in one power device. As a compact combination device of discrete pulse transformer and magnetic switch, the compact TTMS decreases the required volume of magnetic cores in a large scale. The primary windings of the TTMS have a parallel combination structure so that the TTMS which only has 3 turns of secondary windings has a step-up ratio at 1:9. Before the magnetic core saturates, the TTMS has low unsaturated inductances of windings and good pulse response characteristics, so it can be used to substitute the Marx generator to charge the pulse forming line (PFL) at the ranges of several hundred kV and several hundred ns. After the core saturates, the cylindrical conductors can decrease the saturated inductance of the secondary windings of TTMS to a level less than 400 nH. As a result, the proposed TTMS can be used as the boosting transformer and main switch of helical Blumlein PFL to form the quasi-square voltage pulse on the 160 Ω load with a short pulse rise time only at 60 ns.
Zhang, Yu; Liu, Jinliang
2013-02-01
As important devices for voltage boosting and switching, respectively, pulse transformer and magnetic switch are widely used in pulsed power technology. In this paper, a new kind of transformer type magnetic switch (TTMS) with coaxial cylindrical conductors is put forward to combine the functions of voltage boosting and switching in one power device. As a compact combination device of discrete pulse transformer and magnetic switch, the compact TTMS decreases the required volume of magnetic cores in a large scale. The primary windings of the TTMS have a parallel combination structure so that the TTMS which only has 3 turns of secondary windings has a step-up ratio at 1:9. Before the magnetic core saturates, the TTMS has low unsaturated inductances of windings and good pulse response characteristics, so it can be used to substitute the Marx generator to charge the pulse forming line (PFL) at the ranges of several hundred kV and several hundred ns. After the core saturates, the cylindrical conductors can decrease the saturated inductance of the secondary windings of TTMS to a level less than 400 nH. As a result, the proposed TTMS can be used as the boosting transformer and main switch of helical Blumlein PFL to form the quasi-square voltage pulse on the 160 Ω load with a short pulse rise time only at 60 ns.
21 CFR 882.1200 - Two-point discriminator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Two-point discriminator. 882.1200 Section 882.1200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1200 Two-point discriminator...
21 CFR 882.1200 - Two-point discriminator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Two-point discriminator. 882.1200 Section 882.1200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1200 Two-point discriminator...
21 CFR 872.3830 - Endodontic paper point.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endodontic paper point. 872.3830 Section 872.3830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3830 Endodontic paper point. (a) Identification...
21 CFR 872.3840 - Endodontic silver point.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endodontic silver point. 872.3840 Section 872.3840 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3840 Endodontic silver point. (a) Identification...
Uniform rotating field network structure to efficiently package a magnetic bubble domain memory
NASA Technical Reports Server (NTRS)
Murray, Glen W. (Inventor); Chen, Thomas T. (Inventor); Wolfshagen, Ronald G. (Inventor); Ypma, John E. (Inventor)
1978-01-01
A unique and compact open coil rotating magnetic field network structure to efficiently package an array of bubble domain devices is disclosed. The field network has a configuration which effectively enables selected bubble domain devices from the array to be driven in a vertical magnetic field and in an independent and uniform horizontal rotating magnetic field. The field network is suitably adapted to minimize undesirable inductance effects, improve capabilities of heat dissipation, and facilitate repair or replacement of a bubble device.
Quantum Device Applications of Mesoscopic Superconductivity
NASA Astrophysics Data System (ADS)
Hakonen, P. J.
2006-08-01
A brief account is given on the possibilities of mesoscopic superconductivity in low-noise amplifier and detector applications. In particular, three devices will be described: 1) Bloch oscillating transistor (BOT), 2) Inductively-read superconducting Cooper pair transistor (L-SET), and 3) Quantum capacitive phase detector (C-SET). The BOT is a low-noise current amplifier while the L-SET and C-SET act as ultra-sensitive charge and phase detectors, respectively. The basic operating principles and the main characteristics of these devices will be reviewed and discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agustsson, Ronald
In this project, RadiaBeam Technologies was tasked with developing a novel solution for a cost effective quench protection based on fast expansion of the normal zone. By inductively coupling a strong electromagnetic pulse via a resonant LC circuit, we attempted to demonstrate accelerated normal zone propagation. The AC field induces currents in the superconducting layer with the current density exceeding that of the critical current density, J c. This creates a large normal zone, uniformly distributing the dissipation through the magnet body. The method does not rely on thermal heating of the conductor, thus enabling nearly instantaneous protection. Through themore » course of the Phase II project, RadiaBeam Technologies continued extensive numerical modeling of the inductive quench system, re-designed and built several iterations of the POC system for testing and observed evidence of a transient partial quench being induced. However the final device was not fabricated. This was a consequence of the fundamentally complex nature of the energy extraction process and the challenges associated even with demonstrating the proof of concept in a bench top device.« less
Design of an Integrated-System FARAD Thruster
NASA Technical Reports Server (NTRS)
Polzin, K.A.; Rose, R.F.; Miller, R.; Owens, T.
2007-01-01
Pulsed inductive plasma accelerators are spacecraft propulsion devices in which energy is stored in a capacitor and then discharged through an inductive coil. The device is electrodeless, inducing a current s heet in a plasma located near the face of the coil. The propellant is accelerated and expelled at a high exhaust velocity (order of 10 km/s) through the interaction of the plasma current and the induced magne tic field, The Faraday Accelerator with RF-Assisted Discharge (FARAD) thruster is a type of pulsed inductive plasma accelerator in which t he plasma is preionized by a mechanism separate from that used to for m the current sheet and accelerate the gas. Employing a separate preionization mechanism allows for the formation of an inductive current s heet at much lower discharge energies and voltages than those used in previous pulsed inductive accelerators like the Pulsed Inductive Thr uster (PIT). In this paper, we present the design of a benchtop FARAD thruster with all the subsystems (mass injection, preionization, and acceleration) integrated into a single unit. Design of the thruster follows the guidelines and similarity performance parameters presented elsewhere. The system is designed to use the ringing, RF-frequency s ignal produced by a discharging Vector Inversion Generator (VIG) to p reionize the gas. The acceleration stage operates on the order of 100 J/pulse and can be driven by several different pulsed powertrains. These include a simple capacitor coupled to the system, a Bernardes and Merryman configuration, and a pulsecompression circuit that takes a temporally broad, low current pulse and transforms it into a short, h igh current pulse. A set of applied magnetic field coils are integrated into the system to guide the preionized propellant as it spreads ov er the face of the inductive acceleration coil. The coils are operate d in a pulsed mode, and the thruster can be operated without using the coils to determine if there is a performance improvement gain realiz ed when an applied field is present.
NASA Astrophysics Data System (ADS)
Masaud, Tarek
Double Fed Induction Generators (DFIG) has been widely used for the past two decades in large wind farms. However, there are many open-ended problems yet to be solved before they can be implemented in some specific applications. This dissertation deals with the general analysis, modeling, control and applications of the DFIG for large wind farm applications. A detailed "d-q" model of DFIG along with other applications is simulated using the MATLAB/Simulink platform. The simulation results have been discussed in detail in both sub-synchronous and super-synchronous mode of operation. An improved vector control strategy based on the rotor flux oriented vector control has been proposed to control the active power output of the DFIG. The new vector control strategy is compared with the stator flux oriented vector control which is commonly used. It is observed that the new improved vector control method provides a better active power tracking accuracy compare with the stator flux oriented vector control. The behavior of the DFIG -based wind farm under the various grid disturbances is also studied in this dissertation. The implementation of the Flexible AC Transmission System devices (FACTS) to overcome the voltage stability issue for such applications is investigated. The study includes the implementation of both a static synchronous compensator (STATCOM), and the static VAR compensator (SVC) as dynamic reactive power compensators at the point of common coupling to support DFIG-based wind farm during disturbances. Integrating FACTS protect the grid connected DFIG-based wind farm from going offline during and after the disturbances. It is found that the both devices improve the transient performance and therefore helps the wind turbine generator system to remain in service during grid faults. A comparison between the performance of the two devices in terms of the amount of reactive power injected, time response and the application cost has been discussed in this dissertation. Finally, the integration of the battery energy storage system (BESS) into a grid connected DFIG- based wind turbine as a proposed solution to smooth out the output power during wind speed variations is also addressed.
Evaluation of two inflow control devices for flight simulation of fan noise using a JT15D engine
NASA Technical Reports Server (NTRS)
Jones, W. L.; Mcardle, J. G.; Homyak, L.
1979-01-01
The program was developed to accurately simulate flight fan noise on ground static test stands. The results generally indicated that both the induct and external ICD's were effective in reducing the inflow turbulence and the fan blade passing frequency tone generated by the turbulence. The external ICD was essentially transparent to the propagating fan tone but the induct ICD caused attenuation under most conditions.
2011-02-01
and Development Center Fe Iron gpd Gallons per Day HDPE High Density Polyethylene Hg Mercury ICP Inductively Coupled Plasma ICP/MS...Inductively Coupled Plasma Mass Spectrometry IROD Interim Record of Decision ITRC Interstate Technology and Regulatory Council K Potassium Kow...alkaline earth metals, alkali metals, and a metalloid, were sampled. This particular demonstration took place at the McClellan Air Force Base (AFB) in
Device and method for shortening reactor process tubes
Frantz, C.E.; Alexander, W.K.; Lander, W.E.B.
A device and method are described for in situ shortening of nuclear reactor zirconium alloy process tubes which have grown as a result of radiation exposure. An upsetting technique is utilized which involves inductively heating a short band of a process tube with simultaneous application of an axial load sufficient to cause upsetting with an attendant decrease in length of the process tube.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abernathy, C.R.; Hobson, W.S.; Hong, J.
1998-11-04
Current and future generations of sophisticated compound semiconductor devices require the ability for submicron scale patterning. The situation is being complicated since some of the new devices are based on a wider diversity of materials to be etched. Conventional IUE (Reactive Ion Etching) has been prevalent across the industry so far, but has limitations for materials with high bond strengths or multiple elements. IrI this paper, we suggest high density plasmas such as ECR (Electron Cyclotron Resonance) and ICP (Inductively Coupled Plasma), for the etching of ternary compound semiconductors (InGaP, AIInP, AlGaP) which are employed for electronic devices like heterojunctionmore » bipolar transistors (HBTs) or high electron mobility transistors (HEMTs), and photonic devices such as light-emitting diodes (LEDs) and lasers. High density plasma sources, opeiating at lower pressure, are expected to meet target goals determined in terms of etch rate, surface morphology, surface stoichiometry, selectivity, etc. The etching mechanisms, which are described in this paper, can also be applied to other III-V (GaAs-based, InP-based) as well as III-Nitride since the InGaAIP system shares many of the same properties.« less
Low-noise kinetic inductance traveling-wave amplifier using three-wave mixing
NASA Astrophysics Data System (ADS)
Vissers, M. R.; Erickson, R. P.; Ku, H.-S.; Vale, Leila; Wu, Xian; Hilton, G. C.; Pappas, D. P.
2016-01-01
We have fabricated a wide-bandwidth, high dynamic range, low-noise cryogenic amplifier based on a superconducting kinetic inductance traveling-wave device. The device was made from NbTiN and consisted of a long, coplanar waveguide on a silicon chip. By adding a DC current and an RF pump tone, we are able to generate parametric amplification using three-wave mixing (3WM). The devices exhibit gain of more than 15 dB across an instantaneous bandwidth from 4 to 8 GHz. The total usable gain bandwidth, including both sides of the signal-idler gain region, is more than 6 GHz. The noise referred to the input of the devices approaches the quantum limit, with less than 1 photon excess noise. We compare these results directly to the four-wave mixing amplification mode, i.e., without DC-biasing. We find that the 3WM mode allows operation with the pump at lower RF power and at frequencies far from the signal. We have used this knowledge to redesign the amplifiers to utilize primarily 3WM amplification, thereby allowing for direct integration into large scale qubit and detector applications.
Low-noise kinetic inductance traveling-wave amplifier using three-wave mixing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vissers, M. R.; Erickson, R. P.; Ku, H.-S.
We have fabricated a wide-bandwidth, high dynamic range, low-noise cryogenic amplifier based on a superconducting kinetic inductance traveling-wave device. The device was made from NbTiN and consisted of a long, coplanar waveguide on a silicon chip. By adding a DC current and an RF pump tone, we are able to generate parametric amplification using three-wave mixing (3WM). The devices exhibit gain of more than 15 dB across an instantaneous bandwidth from 4 to 8 GHz. The total usable gain bandwidth, including both sides of the signal-idler gain region, is more than 6 GHz. The noise referred to the input of the devices approachesmore » the quantum limit, with less than 1 photon excess noise. We compare these results directly to the four-wave mixing amplification mode, i.e., without DC-biasing. We find that the 3WM mode allows operation with the pump at lower RF power and at frequencies far from the signal. We have used this knowledge to redesign the amplifiers to utilize primarily 3WM amplification, thereby allowing for direct integration into large scale qubit and detector applications.« less
Miyagawa, Yayoi; Ogawa, Takenobu; Nakagawa, Kyuya; Adachi, Shuji
2015-01-01
The induction period of crystallization, which is defined as the time required for oil to start to crystallize, is useful indicator of the freeze-thaw stability of food emulsions such as mayonnaise. We investigated the induction period of vegetable oils with low melting points, such as rapeseed and soybean oils, which are commonly employed for mayonnaise production. The induction period was measured by monitoring the temperature of a specimen during storage at low temperature. The induction period depended on the type of oil and lipophilic emulsifier, emulsifier concentration, and storage temperature. The effect of the oil type on the induction period depended on the composition of the oil. Differential scanning calorimetry (DSC) analyses of the lipophilic emulsifiers suggested that the melting trend of the emulsifier is strongly related to the induction period.
A Novelty Design Of Minimization Of Electrical Losses In A Vector Controlled Induction Machine Drive
NASA Astrophysics Data System (ADS)
Aryza, Solly; Irwanto, M.; Lubis, Zulkarnain; Putera Utama Siahaan, Andysah; Rahim, Robbi; Furqan, Mhd.
2018-01-01
The induction motor has in the industry . More attention has been a focus to develop and design of induction motor drive. With the method of vector control novelty prove the efficiency of induction motor over their entire speed range. In this paper desirable to design a loss minimization controller which can improve the efficiency. Also, this research described Modeling of an induction motor with core loss included. Realization of methods vector control for an induction motor drive with loss element included. The case of the loss minimization condition. The procedure was successful to calculate the gains of a PI controller. Though the problem of obtaining a robust and sensorless induction motor drive is by no means completely solved, the results obtained as part of this work point in a promising direction.
Off-resonance frequency operation for power transfer in a loosely coupled air core transformer
Scudiere, Matthew B
2012-11-13
A power transmission system includes a loosely coupled air core transformer having a resonance frequency determined by a product of inductance and capacitance of a primary circuit including a primary coil. A secondary circuit is configured to have a substantially same product of inductance and capacitance. A back EMF generating device (e.g., a battery), which generates a back EMF with power transfer, is attached to the secondary circuit. Once the load power of the back EMF generating device exceeds a certain threshold level, which depends on the system parameters, the power transfer can be achieved at higher transfer efficiency if performed at an operating frequency less than the resonance frequency, which can be from 50% to 95% of the resonance frequency.
Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and its Application in Life Sciences
NASA Astrophysics Data System (ADS)
Xu, Gu-feng; Wang, Hong-mei
2001-08-01
Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technologies related to plasma source, sample-introducing device and detecting spectrometer etc. In this overview, an emphasis will be put on the evaluation of the ICP-MS technique in combination with a series of physical, chemical and biological techniques, such as laser ablation (LA), capillary electrophoresis (CE) and high performance liquid chromatograph (HPLC), along with their representative high accuracy and high sensitivity. Finally, comprehensive and fruitful applications of the ICP-MS and its combinative techniques in the detection of trace metallic elements and isotopes in complex biological and environmental samples will be revealed.
Microwave Kinetic Inductance Detector with Selective Polarization Coupling
NASA Technical Reports Server (NTRS)
Wollack, Edward; U-yen, Kongpop; Stevenson, Thomas; Brown, Ari; Moseley, Samuel; Hsieh, Wen-Ting
2013-01-01
A conventional low-noise detector requires a technique to both absorb incident power and convert it to an electrical signal at cryogenic temperatures. This innovation combines low-noise detector and readout functionality into one device while maintaining high absorption, controlled polarization sensitivity, and broadband detection capability. The resulting far-infrared detectors can be read out with a simple approach, which is compact and minimizes thermal loading. The proposed microwave kinetic inductance detector (MKID) consists of three basic elements. The first is the absorptive section in which the incident power is coupled to a superconducting resonator at far-infrared frequency above its superconducting critical frequency (where superconductor becomes normal conductor). This absorber's shape effectively absorbs signals in the desired polarization state and is resonant at the radio frequency (RF) used for readout of the device. Control over the metal film used in the absorber allows realization of structures with either a 50% broadband or 100% resonance absorptance over a 30% fractional bandwidth. The second element is a microwave resonator - which is realized from the thin metal films used to make the absorber as transmission lines - whose resonance frequency changes due to a variation in its kinetic inductance. The resonator's kinetic inductance is a function of the power absorbed by the device. A low-loss dielectric (mono-crystalline silicon) is used in a parallel-plate transmission line structure to realize the desired superconducting resonators. There is negligible coupling among the adjacent elements used to define the polarization sensitivity of each detector. The final component of the device is a microwave transmission line, which is coupled to the resonator, and allows detection of changes in resonance frequency for each detector in the focal plane array. The spiral shape of the detector's absorber allows incident power with two polarizations to couple to the detector equally. A stepped impedance resonator was used that allows the incident power absorbed in the detecting membrane area to be uniformly distributed in the detector's transmission line at the RF readout frequency. This maximizes the sensitivity of the detector. The signal is read out via a frequency multiplexing technique that requires a minimum number of interface transmission lines for readout. This reduces the packaging complexity and coupling to the device's thermal environment.
2007-06-01
massive RF power to the antenna feed points without providing an inductive path to earth. Given all the above challenges, and especially the... circuit theory currents are flowing limited by the three parallel 50 ohm resistances and low inductive reactance. This plateaus at eigencurrent...relative to nett TEM cell input power has been calculated: Figure 86 Expected power output from probe, neglecting probe inductance DSTO-RR-0329
An Efficient Fuzzy Controller Design for Parallel Connected Induction Motor Drives
NASA Astrophysics Data System (ADS)
Usha, S.; Subramani, C.
2018-04-01
Generally, an induction motors are highly non-linear and has a complex time varying dynamics. This makes the speed control of an induction motor a challenging issue in the industries. But, due to the recent trends in the power electronic devices and intelligent controllers, the speed control of the induction motor is achieved by including non-linear characteristics also. Conventionally a single inverter is used to run one induction motor in industries. In the traction applications, two or more inductions motors are operated in parallel to reduce the size and cost of induction motors. In this application, the parallel connected induction motors can be driven by a single inverter unit. The stability problems may introduce in the parallel operation under low speed operating conditions. Hence, the speed deviations should be reduce with help of suitable controllers. The speed control of the parallel connected system is performed by PID controller and fuzzy logic controller. In this paper the speed response of the induction motor for the rating of IHP, 1440 rpm, and 50Hz with these controller are compared in time domain specifications. The stability analysis of the system also performed under low speed using matlab platform. The hardware model is developed for speed control using fuzzy logic controller which exhibited superior performances over the other controller.
Device and method for determining freezing points
NASA Technical Reports Server (NTRS)
Mathiprakasam, Balakrishnan (Inventor)
1986-01-01
A freezing point method and device (10) are disclosed. The method and device pertain to an inflection point technique for determining the freezing points of mixtures. In both the method and device (10), the mixture is cooled to a point below its anticipated freezing point and then warmed at a substantially linear rate. During the warming process, the rate of increase of temperature of the mixture is monitored by, for example, thermocouple (28) with the thermocouple output signal being amplified and differentiated by a differentiator (42). The rate of increase of temperature data are analyzed and a peak rate of increase of temperature is identified. In the preferred device (10) a computer (22) is utilized to analyze the rate of increase of temperature data following the warming process. Once the maximum rate of increase of temperature is identified, the corresponding temperature of the mixture is located and earmarked as being substantially equal to the freezing point of the mixture. In a preferred device (10), the computer (22), in addition to collecting the temperature and rate of change of temperature data, controls a programmable power supply (14) to provide a predetermined amount of cooling and warming current to thermoelectric modules (56).
Reiter, Cara P; Christy, Amanda C; Olsen, Cara H; Bentzel, David E
2017-03-01
Mice are routinely anesthetized with isoflurane in an induction chamber. The AVMA Guidelines for the Euthanasia of Animals states that distress should be minimized during euthanasia but does not address this point in regard to induction of anesthesia. Here we evaluated the potential for familiar surroundings to reduce the adrenocortical response of mice during anesthesia induction with isoflurane. However, adding bedding from the animals' home cage to the induction chamber failed to significantly reduce serum cortisol or corticosterone levels in male and female C57BL/6J mice. These results indicate that familiar surroundings do not appear sufficient to reduce the adrenocortical response of mice during anesthesia induction with isoflurane.
Reiter, Cara P; Christy, Amanda C; Olsen, Cara H; Bentzel, David E
2017-01-01
Mice are routinely anesthetized with isoflurane in an induction chamber. The AVMA Guidelines for the Euthanasia of Animals states that distress should be minimized during euthanasia but does not address this point in regard to induction of anesthesia. Here we evaluated the potential for familiar surroundings to reduce the adrenocortical response of mice during anesthesia induction with isoflurane. However, adding bedding from the animals’ home cage to the induction chamber failed to significantly reduce serum cortisol or corticosterone levels in male and female C57BL/6J mice. These results indicate that familiar surroundings do not appear sufficient to reduce the adrenocortical response of mice during anesthesia induction with isoflurane. PMID:28315639
A Study of 4-level DC-DC Boost Inverter with Passive Component Reduction Consideration
NASA Astrophysics Data System (ADS)
Kasiran, A. N.; Ponniran, A.; Harimon, M. A.; Hamzah, H. H.
2018-04-01
This study is to analyze design principles of boost inductor and capacitor used in the 4-level DC-DC boost converter to realize size reduction of passive component referring to their attributes. The important feature of this circuit is that most of the boost-up energy is transferred from the capacitor-clamped to the output side which the small inductance can be used at the input side. The inductance of the boost inductor is designed by referring the inductor current ripple. On the other hand, the capacitance of the capacitor-clamped is designed by considering voltage stress on semiconductor devices and also the used switching frequency. Besides that, according to the design specifications, the required inductance in 4-level DC-DC boost converter is decreased compared to a conventional conventional DC-DC boost converter. Meanwhile, voltage stress on semiconductor device is depending on the maximum voltage ripple of the capacitor-clamped. A 50 W 4-level DC-DC boost converter prototype has been constructed. The results show that the inductor current ripple was 1.15 A when the inductors, 1 mH and 0.11 mH were used in the conventional and 4-level DC-DC boost converters, respectively. Thus, based on the experimental results, it shows that the reduction of passive components by referring to their attributes in 4-level DC-DC boost converter is achieved. Moreover, the decreasing of voltage stress on the semiconductor devices is an advantage for the selection of low ON-resistance of the devices which will contribute to the reduction of the semiconductor conduction loss. The integration result of boost converter and H-bridge inverter is also shown.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-17
...; formerly Docket No. 2007D-0290] Draft Guidance for Industry: Cell Selection Devices for Point of Care Production of Minimally Manipulated Autologous Peripheral Blood Stem Cells; Withdrawal of Draft Guidance...: Cell Selection Devices for Point of Care Production of Minimally Manipulated Autologous Peripheral...
An Implantable Wireless Neural Interface for Recording Cortical Circuit Dynamics in Moving Primates
Borton, David A.; Yin, Ming; Aceros, Juan; Nurmikko, Arto
2013-01-01
Objective Neural interface technology suitable for clinical translation has the potential to significantly impact the lives of amputees, spinal cord injury victims, and those living with severe neuromotor disease. Such systems must be chronically safe, durable, and effective. Approach We have designed and implemented a neural interface microsystem, housed in a compact, subcutaneous, and hermetically sealed titanium enclosure. The implanted device interfaces the brain with a 510k-approved, 100-element silicon-based MEA via a custom hermetic feedthrough design. Full spectrum neural signals were amplified (0.1Hz to 7.8kHz, ×200 gain) and multiplexed by a custom application specific integrated circuit, digitized, and then packaged for transmission. The neural data (24 Mbps) was transmitted by a wireless data link carried on an frequency shift key modulated signal at 3.2GHz and 3.8GHz to a receiver 1 meter away by design as a point-to-point communication link for human clinical use. The system was powered by an embedded medical grade rechargeable Li-ion battery for 7-hour continuous operation between recharge via an inductive transcutaneous wireless power link at 2MHz. Main results Device verification and early validation was performed in both swine and non-human primate freely-moving animal models and showed that the wireless implant was electrically stable, effective in capturing and delivering broadband neural data, and safe for over one year of testing. In addition, we have used the multichannel data from these mobile animal models to demonstrate the ability to decode neural population dynamics associated with motor activity. Significance We have developed an implanted wireless broadband neural recording device evaluated in non-human primate and swine. The use of this new implantable neural interface technology can provide insight on how to advance human neuroprostheses beyond the present early clinical trials. Further, such tools enable mobile patient use, have the potential for wider diagnosis of neurological conditions, and will advance brain research. PMID:23428937
An implantable wireless neural interface for recording cortical circuit dynamics in moving primates
NASA Astrophysics Data System (ADS)
Borton, David A.; Yin, Ming; Aceros, Juan; Nurmikko, Arto
2013-04-01
Objective. Neural interface technology suitable for clinical translation has the potential to significantly impact the lives of amputees, spinal cord injury victims and those living with severe neuromotor disease. Such systems must be chronically safe, durable and effective. Approach. We have designed and implemented a neural interface microsystem, housed in a compact, subcutaneous and hermetically sealed titanium enclosure. The implanted device interfaces the brain with a 510k-approved, 100-element silicon-based microelectrode array via a custom hermetic feedthrough design. Full spectrum neural signals were amplified (0.1 Hz to 7.8 kHz, 200× gain) and multiplexed by a custom application specific integrated circuit, digitized and then packaged for transmission. The neural data (24 Mbps) were transmitted by a wireless data link carried on a frequency-shift-key-modulated signal at 3.2 and 3.8 GHz to a receiver 1 m away by design as a point-to-point communication link for human clinical use. The system was powered by an embedded medical grade rechargeable Li-ion battery for 7 h continuous operation between recharge via an inductive transcutaneous wireless power link at 2 MHz. Main results. Device verification and early validation were performed in both swine and non-human primate freely-moving animal models and showed that the wireless implant was electrically stable, effective in capturing and delivering broadband neural data, and safe for over one year of testing. In addition, we have used the multichannel data from these mobile animal models to demonstrate the ability to decode neural population dynamics associated with motor activity. Significance. We have developed an implanted wireless broadband neural recording device evaluated in non-human primate and swine. The use of this new implantable neural interface technology can provide insight into how to advance human neuroprostheses beyond the present early clinical trials. Further, such tools enable mobile patient use, have the potential for wider diagnosis of neurological conditions and will advance brain research.
NASA Astrophysics Data System (ADS)
Roy, M.; Sengupta, M.
2012-09-01
Induction heating is a non-contact heating process which became popular due to its energy efficiency. Current source inverter (CSI) based induction heating units are commonly used in the industry. Most of these CSIs are thyristor based, since thyristors of higher ratings are easily available. These being load commutated apparatus a start-up circuit is needed to initiate commutation. In this paper the design and fabrication of two laboratory prototypes have been presented. The first one, a SCR-based CSI fed controlled induction heating unit (IHU), has been tested with two different types of start-up procedures. Thereafter the fabrication and performance of another IGBT-based CSI is compared with the thyristor-based CSI for a 2 kW, 10 kHz application. These two types of CSIs are fully fabricated in laboratory along with the IHU. Performance analysis and simulation of two different CSIs has been done by using SequelGUI2. The triggering pulses for the inverter devices (for both CSI devices as well as auxilliary thyristor of start-up circuit) have been generated and closed-loop control has been done in FPGA platform built around an Altera make cyclone EPIC12Q240C processor which can be programmed using Quartus II software. Close agreement between simulated and experimental results highlight the accuracy of the experimental work.
Device and method for shortening reactor process tubes
Frantz, Charles E.; Alexander, William K.; Lander, Walter E. B.
1980-01-01
This disclosure describes a device and method for in situ shortening of nuclear reactor zirconium alloy process tubes which have grown as a result of radiation exposure. An upsetting technique is utilized which involves inductively heating a short band of a process tube with simultaneous application of an axial load sufficient to cause upsetting with an attendant decrease in length of the process tube.
Kelly, S L; Parry, J M
1983-03-01
Irradiation of yeast cultures with ultraviolet light at discrete stages during meiosis produces cyclic variations in sensitivity, i.e. cells are more sensitive to the lethal effects of UV light prior to entry into the meiotic DNA synthesis, and this corresponds to a peak of induction of point mutation. Cells become more resistant to both induced point mutation and lethality as they enter meiotic DNA synthesis, but become more sensitive again during spore formation. The induced level of intragenic recombination rises during the period of commitment to recombination to a level indistinguishable from the full meiotic level of spontaneous intragenic recombination. Induced reciprocal recombination remains above the spontaneous level up to the point of commitment to sporulation.
Apparatus and method for creating a photonic densely-accumulated ray-point
NASA Technical Reports Server (NTRS)
Park, Yeonjoon (Inventor); Choi, Sang H. (Inventor); King, Glen C. (Inventor); Elliott, James R. (Inventor)
2012-01-01
An optical apparatus includes an optical diffraction device configured for diffracting a predetermined wavelength of incident light onto adjacent optical focal points, and a photon detector for detecting a spectral characteristic of the predetermined wavelength. One of the optical focal points is a constructive interference point and the other optical focal point is a destructive interference point. The diffraction device, which may be a micro-zone plate (MZP) of micro-ring gratings or an optical lens, generates a constructive ray point using phase-contrasting of the destructive interference point. The ray point is located between adjacent optical focal points. A method of generating a densely-accumulated ray point includes directing incident light onto the optical diffraction device, diffracting the selected wavelength onto the constructive interference focal point and the destructive interference focal point, and generating the densely-accumulated ray point in a narrow region.
High power density dc/dc converter: Selection of converter topology
NASA Technical Reports Server (NTRS)
Divan, Deepakraj M.
1990-01-01
The work involved in the identification and selection of a suitable converter topology is described. Three new dc/dc converter topologies are proposed: Phase-Shifted Single Active Bridge DC/DC Converter; Single Phase Dual Active Bridges DC/DC Converter; and Three Phase Dual Active Bridges DC/DC Converter (Topology C). The salient features of these topologies are: (1) All are minimal in structure, i.e., each consists of an input and output bridge, input and output filter and a transformer, all components essential for a high power dc/dc conversion process; (2) All devices of both the bridges can operate under near zero-voltage conditions, making possible a reduction of device switching losses and hence, an increase in switching frequency; (3) All circuits operate at a constant frequency, thus simplifying the task of the magnetic and filter elements; (4) Since, the leakage inductance of the transformer is used as the main current transfer element, problems associated with the diode reverse recovery are eliminated. Also, this mode of operation allows easy paralleling of multiple modules for extending the power capacity of the system; (5) All circuits are least sensitive to parasitic impedances, infact the parasitics are efficently utilized; and (6) The soft switching transitions, result in low electromagnetic interference. A detailed analysis of each topology was carried out. Based on the analysis, the various device and component ratings for each topology operating at an optimum point, and under the given specifications, are tabulated and discussed.
Space station power semiconductor package
NASA Technical Reports Server (NTRS)
Balodis, Vilnis; Berman, Albert; Devance, Darrell; Ludlow, Gerry; Wagner, Lee
1987-01-01
A package of high-power switching semiconductors for the space station have been designed and fabricated. The package includes a high-voltage (600 volts) high current (50 amps) NPN Fast Switching Power Transistor and a high-voltage (1200 volts), high-current (50 amps) Fast Recovery Diode. The package features an isolated collector for the transistors and an isolated anode for the diode. Beryllia is used as the isolation material resulting in a thermal resistance for both devices of .2 degrees per watt. Additional features include a hermetical seal for long life -- greater than 10 years in a space environment. Also, the package design resulted in a low electrical energy loss with the reduction of eddy currents, stray inductances, circuit inductance, and capacitance. The required package design and device parameters have been achieved. Test results for the transistor and diode utilizing the space station package is given.
NASA Technical Reports Server (NTRS)
Bose, Bimal K.; Kim, Min-Huei
1995-01-01
The report essentially summarizes the work performed in order to satisfy the above project objective. In the beginning, different energy storage devices, such as battery, flywheel and ultra capacitor are reviewed and compared, establishing the superiority of the battery. Then, the possible power sources, such as IC engine, diesel engine, gas turbine and fuel cell are reviewed and compared, and the superiority of IC engine has been established. Different types of machines for drive motor/engine generator, such as induction machine, PM synchronous machine and switched reluctance machine are compared, and the induction machine is established as the superior candidate. Similar discussion was made for power converters and devices. The Insulated Gate Bipolar Transistor (IGBT) appears to be the most superior device although Mercury Cadmium Telluride (MCT) shows future promise. Different types of candidate distribution systems with the possible combinations of power and energy sources have been discussed and the most viable system consisting of battery, IC engine and induction machine has been identified. Then, HFAC system has been compared with the DC system establishing the superiority of the former. The detailed component sizing calculations of HFAC and DC systems reinforce the superiority of the former. A preliminary control strategy has been developed for the candidate HFAC system. Finally, modeling and simulation study have been made to validate the system performance. The study in the report demonstrates the superiority of HFAC distribution system for next generation electric/hybrid vehicle.
Performance Analysis of Three-Phase Induction Motor with AC Direct and VFD
NASA Astrophysics Data System (ADS)
Kumar, Dinesh
2018-03-01
The electrical machine analysis and performance calculation is a very important aspect of efficient drive system design. The development of power electronics devices and power converters provide smooth speed control of Induction Motors by changing the frequency of input supply. These converters, on one hand are providing a more flexible speed control that also leads to problems of harmonics and their associated ailments like pulsating torque, distorted current and voltage waveforms, increasing losses etc. This paper includes the performance analysis of three phase induction motor with three-phase AC direct and variable frequency drives (VFD). The comparison has been concluded with respect to various parameters. MATLAB-SIMULINKTM is used for the analysis.
Induction Mapping of the 3D-Modulated Spin Texture of Skyrmions in Thin Helimagnets
NASA Astrophysics Data System (ADS)
Schneider, S.; Wolf, D.; Stolt, M. J.; Jin, S.; Pohl, D.; Rellinghaus, B.; Schmidt, M.; Büchner, B.; Goennenwein, S. T. B.; Nielsch, K.; Lubk, A.
2018-05-01
Envisaged applications of Skyrmions in magnetic memory and logic devices crucially depend on the stability and mobility of these topologically nontrivial magnetic textures in thin films. We present for the first time quantitative maps of the magnetic induction that provide evidence for a 3D modulation of the Skyrmionic spin texture. The projected in-plane magnetic induction maps as determined from in-line and off-axis electron holography carry the clear signature of Bloch Skyrmions. However, the magnitude of this induction is much smaller than the values expected for homogeneous Bloch Skyrmions that extend throughout the thickness of the film. This finding can only be understood if the underlying spin textures are modulated along the out-of-plane z direction. The projection of (the in-plane magnetic induction of) helices is further found to exhibit thickness-dependent lateral shifts, which show that this z modulation is accompanied by an (in-plane) modulation along the x and y directions.
NASA Astrophysics Data System (ADS)
Anwar, M. S.; Lee, S. R.; Ishiguro, R.; Sugimoto, Y.; Tano, Y.; Kang, S. J.; Shin, Y. J.; Yonezawa, S.; Manske, D.; Takayanagi, H.; Noh, T. W.; Maeno, Y.
2016-10-01
Efforts have been ongoing to establish superconducting spintronics utilizing ferromagnet/superconductor heterostructures. Previously reported devices are based on spin-singlet superconductors (SSCs), where the spin degree of freedom is lost. Spin-polarized supercurrent induction in ferromagnetic metals (FMs) is achieved even with SSCs, but only with the aid of interfacial complex magnetic structures, which severely affect information imprinted to the electron spin. Use of spin-triplet superconductors (TSCs) with spin-polarizable Cooper pairs potentially overcomes this difficulty and further leads to novel functionalities. Here, we report spin-triplet superconductivity induction into a FM SrRuO3 from a leading TSC candidate Sr2RuO4, by fabricating microscopic devices using an epitaxial SrRuO3/Sr2RuO4 hybrid. The differential conductance, exhibiting Andreev-reflection features with multiple energy scales up to around half tesla, indicates the penetration of superconductivity over a considerable distance of 15 nm across the SrRuO3 layer without help of interfacial complex magnetism. This demonstrates potential utility of FM/TSC devices for superspintronics.
Anwar, M. S.; Lee, S. R.; Ishiguro, R.; Sugimoto, Y.; Tano, Y.; Kang, S. J.; Shin, Y. J.; Yonezawa, S.; Manske, D.; Takayanagi, H.; Noh, T. W.; Maeno, Y.
2016-01-01
Efforts have been ongoing to establish superconducting spintronics utilizing ferromagnet/superconductor heterostructures. Previously reported devices are based on spin-singlet superconductors (SSCs), where the spin degree of freedom is lost. Spin-polarized supercurrent induction in ferromagnetic metals (FMs) is achieved even with SSCs, but only with the aid of interfacial complex magnetic structures, which severely affect information imprinted to the electron spin. Use of spin-triplet superconductors (TSCs) with spin-polarizable Cooper pairs potentially overcomes this difficulty and further leads to novel functionalities. Here, we report spin-triplet superconductivity induction into a FM SrRuO3 from a leading TSC candidate Sr2RuO4, by fabricating microscopic devices using an epitaxial SrRuO3/Sr2RuO4 hybrid. The differential conductance, exhibiting Andreev-reflection features with multiple energy scales up to around half tesla, indicates the penetration of superconductivity over a considerable distance of 15 nm across the SrRuO3 layer without help of interfacial complex magnetism. This demonstrates potential utility of FM/TSC devices for superspintronics. PMID:27782151
Measuring Multiple Resistances Using Single-Point Excitation
NASA Technical Reports Server (NTRS)
Hall, Dan; Davies, Frank
2009-01-01
In a proposed method of determining the resistances of individual DC electrical devices connected in a series or parallel string, no attempt would be made to perform direct measurements on individual devices. Instead, (1) the devices would be instrumented by connecting reactive circuit components in parallel and/or in series with the devices, as appropriate; (2) a pulse or AC voltage excitation would be applied at a single point on the string; and (3) the transient or AC steady-state current response of the string would be measured at that point only. Each reactive component(s) associated with each device would be distinct in order to associate a unique time-dependent response with that device.
Micro Ring Grating Spectrometer with Adjustable Aperture
NASA Technical Reports Server (NTRS)
Park, Yeonjoon (Inventor); King, Glen C. (Inventor); Elliott, James R. (Inventor); Choi, Sang H. (Inventor)
2012-01-01
A spectrometer includes a micro-ring grating device having coaxially-aligned ring gratings for diffracting incident light onto a target focal point, a detection device for detecting light intensity, one or more actuators, and an adjustable aperture device defining a circular aperture. The aperture circumscribes a target focal point, and directs a light to the detection device. The aperture device is selectively adjustable using the actuators to select a portion of a frequency band for transmission to the detection device. A method of detecting intensity of a selected band of incident light includes directing incident light onto coaxially-aligned ring gratings of a micro-ring grating device, and diffracting the selected band onto a target focal point using the ring gratings. The method includes using an actuator to adjust an aperture device and pass a selected portion of the frequency band to a detection device for measuring the intensity of the selected portion.
NASA Astrophysics Data System (ADS)
Laborda, Francisco; Medrano, Jesús; Castillo, Juan R.
2004-06-01
The quality of the quantitative results obtained from transient signals in high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) and flow injection-inductively coupled plasma mass spectrometry (FI-ICPMS) was investigated under multielement conditions. Quantification methods were based on multiple-point calibration by simple and weighted linear regression, and double-point calibration (measurement of the baseline and one standard). An uncertainty model, which includes the main sources of uncertainty from FI-ICPMS and HPLC-ICPMS (signal measurement, sample flow rate and injection volume), was developed to estimate peak area uncertainties and statistical weights used in weighted linear regression. The behaviour of the ICPMS instrument was characterized in order to be considered in the model, concluding that the instrument works as a concentration detector when it is used to monitorize transient signals from flow injection or chromatographic separations. Proper quantification by the three calibration methods was achieved when compared to reference materials, although the double-point calibration allowed to obtain results of the same quality as the multiple-point calibration, shortening the calibration time. Relative expanded uncertainties ranged from 10-20% for concentrations around the LOQ to 5% for concentrations higher than 100 times the LOQ.
Giménez-Arnau, A M
2016-04-01
The information provided does not support the safe use of MI as a preservative in rinse-off cosmetic products up to a concentration limit of 100 ppm from the view of induction of contact allergy. For rinse-off cosmetic products, a concentration of 15 ppm (0.0015%) MI is considered safe for the consumer from the point of view of induction of contact allergy. The information provided does not support the safe use of MI as a preservative in leave-on hair cosmetic products up to a concentration limit of 100 ppm from the point of view of induction of contact allergy. The concerns and opinions raised in SCCS Opinion SCCS/1521/13 (12 December 2013 with revision 27 March 2014) remain. The results of the recent Scandinavian study do not support safety of MI in rinse-off products at either 100 ppm or at 50 ppm for elicitation or induction. Copyright © 2016. Published by Elsevier Inc.
Skeist, S. Merrill; Baker, Richard H.
2006-01-10
An electro-mechanical energy conversion system coupled between an energy source and an energy load comprising an energy converter device including a permanent magnet induction machine coupled between the energy source and the energy load to convert the energy from the energy source and to transfer the converted energy to the energy load and an energy transfer multiplexer to control the flow of power or energy through the permanent magnetic induction machine.
Pulsed magnetic field excitation sensitivity of match-type electric blasting caps
NASA Astrophysics Data System (ADS)
Parson, Jonathan; Dickens, James; Walter, John; Neuber, Andreas A.
2010-10-01
This paper presents a study on energy deposition and electromagnetic compatibility of match-type electroexplosive devices (EEDs), which recently have found more usage in pulsed power environments with high electromagnetic interference (EMI) background. The sensitivity of these devices makes them dangerous to intended and unintended radiation produced by devices commonly used in pulsed power environments. Match-type EEDs have been found to be susceptible to such low levels of energy (7-8 mJ) that safe operation of these EEDs is vital when in use near devices that produce high levels of pulsed EMI. The scope of this paper is to provide an investigation that incorporates results of similar studies to provide detonation characteristics of these EEDs. The three topics included in this study are sensitivity testing, modeling of the thermodynamic heat propagation, and electromagnetic compatibility from pulsed electromagnetic radiation. The thermodynamic joule heating of the primary explosive has been modeled by a solution to the 1D heat equation. A simple pulsed generator, Marx generator with an inductive load, was used for the electromagnetic compatibility assessment of the coupled field between the pulse generator and shorted EED. The results of the electromagnetic compatibility assessment relate the resistive, inductive, and capacitive components of the pulse generator to the area of the shorted EED.
Pulsed magnetic field excitation sensitivity of match-type electric blasting caps.
Parson, Jonathan; Dickens, James; Walter, John; Neuber, Andreas A
2010-10-01
This paper presents a study on energy deposition and electromagnetic compatibility of match-type electroexplosive devices (EEDs), which recently have found more usage in pulsed power environments with high electromagnetic interference (EMI) background. The sensitivity of these devices makes them dangerous to intended and unintended radiation produced by devices commonly used in pulsed power environments. Match-type EEDs have been found to be susceptible to such low levels of energy (7-8 mJ) that safe operation of these EEDs is vital when in use near devices that produce high levels of pulsed EMI. The scope of this paper is to provide an investigation that incorporates results of similar studies to provide detonation characteristics of these EEDs. The three topics included in this study are sensitivity testing, modeling of the thermodynamic heat propagation, and electromagnetic compatibility from pulsed electromagnetic radiation. The thermodynamic joule heating of the primary explosive has been modeled by a solution to the 1D heat equation. A simple pulsed generator, Marx generator with an inductive load, was used for the electromagnetic compatibility assessment of the coupled field between the pulse generator and shorted EED. The results of the electromagnetic compatibility assessment relate the resistive, inductive, and capacitive components of the pulse generator to the area of the shorted EED.
Ghezzi, Diego; Menegon, Andrea; Pedrocchi, Alessandra; Valtorta, Flavia; Ferrigno, Giancarlo
2008-10-30
Optical stimulation is a promising approach to investigate the local dynamic responses of cultured neurons. In particular, flash photolysis of caged compounds offers the advantage of allowing the rapid change of concentration of either extracellular or intracellular molecules, such as neurotransmitters or second messengers, for the stimulation or modulation of neuronal activity. We describe here the use of an ultra-violet (UV) laser diode coupled to an optical fibre for the local activation of caged compounds combined with a Micro-Electrode Array (MEA) device. Local uncaging was achieved by UV irradiation through the optical fibre previously positioned by using a red laser diode. The size of the stimulation was determined using caged fluorescein, whereas its efficacy was tested by studying the effect of uncaging the neurotransmitter glutamate. Uncaged glutamate evoked neuronal responses that were recorded using either fluorescence measurements or electrophysiological recordings with MEAs, thus showing the ability of our system to induce local neuronal excitation. This method allows overcoming the limitations of the MEA system related to unfocused electrical stimulation and induction of electrical artefacts. In addition, the coupling of a UV laser diode to an optical fibre allows a precise local stimulation and a quick change of the stimulation point.
RFEA measurements of high-energy electrons in a helicon plasma device with expanding magnetic field
NASA Astrophysics Data System (ADS)
Gulbrandsen, Njål; Fredriksen, Åshild
2017-01-01
In the inductively coupled plasma of the Njord helicon device we have, for the same parameters as for which an ion beam exists, measured a downstream population of high-energy electrons emerging from the source. Separated measurements of energetic tail electrons was carried out by Retarding Field Energy Analyzer (RFEA) with a grounded entrance grid, operated in an electron collection mode. In a radial scan with the RFEA pointed toward the source, we found a significant population of high-energy electrons just inside the magnetic field line mapping to the edge of the source. A second peak in high-energy electrons density was observed in a radial position corresponding to the radius of the source. Also, throughout the main column a small contribution of high-energy electrons was observed. In a radial scan with a RFEA biased to collect ions a localized increase in the plasma ion density near the magnetic field line emerging from the plasma near the wall of the source was observed. This is interpreted as a signature of high-energy electrons ionizing the neutral gas. Also, a dip in the floating potential of a Langmuir probe is evident in this region where high-energy electrons is observed.
Micro-Fresnel Zone Plate Optical Devices Using Densely Accumulated Ray Points
NASA Technical Reports Server (NTRS)
Choi, Sang H. (Inventor); Park, Yeonjoon (Inventor); King, Glen C. (Inventor); Elliott, James R. (Inventor)
2011-01-01
An embodiment generally relates to an optical device suitable for use with an optical medium for the storage and retrieval of data. The optical device includes an illumination means for providing a beam of optical radiation of wavelength .lamda. and an optical path that the beam of optical radiation follows. The optical device also includes a diffractive optical element defined by a plurality of annular sections. The plurality of annular sections having a first material alternately disposed with a plurality of annular sections comprising a second material. The diffractive optical element generates a plurality of focal points and densely accumulated ray points with phase contrast phenomena and the optical medium is positioned at a selected focal point or ray point of the diffractive optical element.
Push-pull switching power amplifier
NASA Technical Reports Server (NTRS)
Cuk, Slobodan M. (Inventor)
1980-01-01
A true push-pull switching power amplifier is disclosed utilizing two dc-to-dc converters. Each converter is comprised of two inductances, one inductance in series with a DC source and the other inductor in series with the output load, and an electrical energy transferring device with storage capability, namely storage capacitance, with suitable switching means between the inductances to obtain DC level conversion, where the switching means allows bidirectional current (and power) flow, and the switching means of one dc-to-dc converter is driven by the complement of a square-wave switching signal for the other dc-to-dc converter for true push-pull operation. For reduction of current ripple, the inductances in each of the two converters may be coupled, and with proper design of the coupling, the ripple can be reduced to zero at either the input or the output, but preferably the output.
Subranging technique using superconducting technology
Gupta, Deepnarayan
2003-01-01
Subranging techniques using "digital SQUIDs" are used to design systems with large dynamic range, high resolution and large bandwidth. Analog-to-digital converters (ADCs) embodying the invention include a first SQUID based "coarse" resolution circuit and a second SQUID based "fine" resolution circuit to convert an analog input signal into "coarse" and "fine" digital signals for subsequent processing. In one embodiment, an ADC includes circuitry for supplying an analog input signal to an input coil having at least a first inductive section and a second inductive section. A first superconducting quantum interference device (SQUID) is coupled to the first inductive section and a second SQUID is coupled to the second inductive section. The first SQUID is designed to produce "coarse" (large amplitude, low resolution) output signals and the second SQUID is designed to produce "fine" (low amplitude, high resolution) output signals in response to the analog input signals.
Mushambi, M C; Kinsella, S M; Popat, M; Swales, H; Ramaswamy, K K; Winton, A L; Quinn, A C
2015-11-01
The Obstetric Anaesthetists' Association and Difficult Airway Society have developed the first national obstetric guidelines for the safe management of difficult and failed tracheal intubation during general anaesthesia. They comprise four algorithms and two tables. A master algorithm provides an overview. Algorithm 1 gives a framework on how to optimise a safe general anaesthetic technique in the obstetric patient, and emphasises: planning and multidisciplinary communication; how to prevent the rapid oxygen desaturation seen in pregnant women by advocating nasal oxygenation and mask ventilation immediately after induction; limiting intubation attempts to two; and consideration of early release of cricoid pressure if difficulties are encountered. Algorithm 2 summarises the management after declaring failed tracheal intubation with clear decision points, and encourages early insertion of a (preferably second-generation) supraglottic airway device if appropriate. Algorithm 3 covers the management of the 'can't intubate, can't oxygenate' situation and emergency front-of-neck airway access, including the necessity for timely perimortem caesarean section if maternal oxygenation cannot be achieved. Table 1 gives a structure for assessing the individual factors relevant in the decision to awaken or proceed should intubation fail, which include: urgency related to maternal or fetal factors; seniority of the anaesthetist; obesity of the patient; surgical complexity; aspiration risk; potential difficulty with provision of alternative anaesthesia; and post-induction airway device and airway patency. This decision should be considered by the team in advance of performing a general anaesthetic to make a provisional plan should failed intubation occur. The table is also intended to be used as a teaching tool to facilitate discussion and learning regarding the complex nature of decision-making when faced with a failed intubation. Table 2 gives practical considerations of how to awaken or proceed with surgery. The background paper covers recommendations on drugs, new equipment, teaching and training. © 2015 The Authors. Anaesthesia published by John Wiley & Sons Ltd on behalf of Association of Anaesthetists of Great Britain and Ireland.
Mushambi, M C; Kinsella, S M; Popat, M; Swales, H; Ramaswamy, K K; Winton, A L; Quinn, A C
2015-01-01
The Obstetric Anaesthetists' Association and Difficult Airway Society have developed the first national obstetric guidelines for the safe management of difficult and failed tracheal intubation during general anaesthesia. They comprise four algorithms and two tables. A master algorithm provides an overview. Algorithm 1 gives a framework on how to optimise a safe general anaesthetic technique in the obstetric patient, and emphasises: planning and multidisciplinary communication; how to prevent the rapid oxygen desaturation seen in pregnant women by advocating nasal oxygenation and mask ventilation immediately after induction; limiting intubation attempts to two; and consideration of early release of cricoid pressure if difficulties are encountered. Algorithm 2 summarises the management after declaring failed tracheal intubation with clear decision points, and encourages early insertion of a (preferably second-generation) supraglottic airway device if appropriate. Algorithm 3 covers the management of the ‘can't intubate, can't oxygenate’ situation and emergency front-of-neck airway access, including the necessity for timely perimortem caesarean section if maternal oxygenation cannot be achieved. Table 1 gives a structure for assessing the individual factors relevant in the decision to awaken or proceed should intubation fail, which include: urgency related to maternal or fetal factors; seniority of the anaesthetist; obesity of the patient; surgical complexity; aspiration risk; potential difficulty with provision of alternative anaesthesia; and post-induction airway device and airway patency. This decision should be considered by the team in advance of performing a general anaesthetic to make a provisional plan should failed intubation occur. The table is also intended to be used as a teaching tool to facilitate discussion and learning regarding the complex nature of decision-making when faced with a failed intubation. Table 2 gives practical considerations of how to awaken or proceed with surgery. The background paper covers recommendations on drugs, new equipment, teaching and training. PMID:26449292
Caruba, Thibaut; Grosjean, Sandrine; Amour, Julien; Ouattara, Alexandre; Villacorta, Judith; Miguet, Bertrand; Guinet, Patrick; Lévy, François; Squara, Pierre; Aït Hamou, Nora; Carillon, Aude; Boyer, Julie; Boughenou, Marie-Fazia; Rosier, Sebastien; Robin, Emmanuel; Radutoiu, Mihail; Durand, Michel; Guidon, Catherine; Desebbe, Olivier; Charles-Nelson, Anaïs; Menasché, Philippe; Rozec, Bertrand; Girard, Claude; Fellahi, Jean-Luc; Pirracchio, Romain; Chatellier, Gilles
2017-01-01
Importance Low cardiac output syndrome after cardiac surgery is associated with high morbidity and mortality in patients with impaired left ventricular function. Objective To assess the ability of preoperative levosimendan to prevent postoperative low cardiac output syndrome. Design, Setting, and Participants Randomized, double-blind, placebo-controlled trial conducted in 13 French cardiac surgical centers. Patients with a left ventricular ejection fraction less than or equal to 40% and scheduled for isolated or combined coronary artery bypass grafting with cardiopulmonary bypass were enrolled from June 2013 until May 2015 and followed during 6 months (last follow-up, November 30, 2015). Interventions Patients were assigned to a 24-hour infusion of levosimendan 0.1 µg/kg/min (n = 167) or placebo (n = 168) initiated after anesthetic induction. Main Outcomes and Measures Composite end point reflecting low cardiac output syndrome with need for a catecholamine infusion 48 hours after study drug initiation, need for a left ventricular mechanical assist device or failure to wean from it at 96 hours after study drug initiation when the device was inserted preoperatively, or need for renal replacement therapy at any time postoperatively. It was hypothesized that levosimendan would reduce the incidence of this composite end point by 15% in comparison with placebo. Results Among 336 randomized patients (mean age, 68 years; 16% women), 333 completed the trial. The primary end point occurred in 87 patients (52%) in the levosimendan group and 101 patients (61%) in the placebo group (absolute risk difference taking into account center effect, −7% [95% CI, −17% to 3%]; P = .15). Predefined subgroup analyses found no interaction with ejection fraction less than 30%, type of surgery, and preoperative use of β-blockers, intra-aortic balloon pump, or catecholamines. The prevalence of hypotension (57% vs 48%), atrial fibrillation (50% vs 40%), and other adverse events did not significantly differ between levosimendan and placebo. Conclusions and Relevance Among patients with low ejection fraction who were undergoing coronary artery bypass grafting with cardiopulmonary bypass, levosimendan compared with placebo did not result in a significant difference in the composite end point of prolonged catecholamine infusion, use of left ventricular mechanical assist device, or renal replacement therapy. These findings do not support the use of levosimendan for this indication. Trial Registration EudraCT Number: 2012-000232-25; clinicaltrials.gov Identifier: NCT02184819 PMID:28787507
Induction of labor in the obese patient.
Ruhstaller, Kelly
2015-10-01
Obese women are at an increased risk of antepartum pregnancy complications and are therefore more likely to require an induction of labor than normal weight women. They also have an increased rate of failing an induction of labor, a rate that rises significantly with increasing body mass index, and subsequent surgical and neonatal complications of an intrapartum cesarean delivery. This increase in induction failure may be due to differences in the myometrium of obese women resulting in decreased contraction strength. There have been only a few studies comparing the efficacy of the various cervical ripening agents in obese women and at this point no recommendation can be made as to what method may result in the greatest chance of a successful induction. Copyright © 2015. Published by Elsevier Inc.
ERIC Educational Resources Information Center
Rahmatian, Rouhollah; Zarekar, Fatemeh
2016-01-01
This article defines the objective of discovering the first preferred styles of Iranian learners of French as a Foreign Language (FFL) as regards inductive or deductive learning; and secondly, the difference between gender-based learning tendencies. Considering these points as target variables, the questionnaire developed by Felder and Silverman…
A 5 kA pulsed power supply for inductive and plasma loads in large volume plasma device.
Srivastava, P K; Singh, S K; Sanyasi, A K; Awasthi, L M; Mattoo, S K
2016-07-01
This paper describes 5 kA, 12 ms pulsed power supply for inductive load of Electron Energy Filter (EEF) in large volume plasma device. The power supply is based upon the principle of rapid sourcing of energy from the capacitor bank (2.8 F/200 V) by using a static switch, comprising of ten Insulated Gate Bipolar Transistors (IGBTs). A suitable mechanism is developed to ensure equal sharing of current and uniform power distribution during the operation of these IGBTs. Safe commutation of power to the EEF is ensured by the proper optimization of its components and by the introduction of over voltage protection (>6 kV) using an indigenously designed snubber circuit. Various time sequences relevant to different actions of power supply, viz., pulse width control and repetition rate, are realized through optically isolated computer controlled interface.
A 5 kA pulsed power supply for inductive and plasma loads in large volume plasma device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Srivastava, P. K., E-mail: pkumar@ipr.res.in; Singh, S. K.; Sanyasi, A. K.
This paper describes 5 kA, 12 ms pulsed power supply for inductive load of Electron Energy Filter (EEF) in large volume plasma device. The power supply is based upon the principle of rapid sourcing of energy from the capacitor bank (2.8 F/200 V) by using a static switch, comprising of ten Insulated Gate Bipolar Transistors (IGBTs). A suitable mechanism is developed to ensure equal sharing of current and uniform power distribution during the operation of these IGBTs. Safe commutation of power to the EEF is ensured by the proper optimization of its components and by the introduction of over voltagemore » protection (>6 kV) using an indigenously designed snubber circuit. Various time sequences relevant to different actions of power supply, viz., pulse width control and repetition rate, are realized through optically isolated computer controlled interface.« less
NASA Technical Reports Server (NTRS)
Wittmann, A.; Willay, G.
1986-01-01
For a rapid preparation of solutions intended for analysis by inductively coupled plasma emission spectrometry or atomic absorption spectrometry, an automatic device called Plasmasol was developed. This apparatus used the property of nonwettability of glassy C to fuse the sample in an appropriate flux. The sample-flux mixture is placed in a composite crucible, then heated at high temperature, swirled until full dissolution is achieved, and then poured into a water-filled beaker. After acid addition, dissolution of the melt, and filling to the mark, the solution is ready for analysis. The analytical results obtained, either for oxide samples or for prereduced iron ores show that the solutions prepared with this device are undistinguished from those obtained by manual dissolutions done by acid digestion or by high temperature fusion. Preparation reproducibility and analytical tests illustrate the performance of Plasmasol.
Calibration of a magnetic induction system for measurement of hypervelocities
NASA Astrophysics Data System (ADS)
Breeze, S. P.
1993-03-01
A device to measure the velocity and to determine the character of a material launched in a flight tube during the execution of an experiment has been constructed. This measurement device provides a self generating signal, is nonintrusive, compact, and accurate. The signals are reproducible, and it is relatively inexpensive to procure. The MAgnetic Velocity Induction System (MAVIS) has been the technique used to measure projectile velocities in the two-stage light gas gun at Sandia for many years. Several experiments were conducted to study the MAVIS data signatures produced by various metal projectiles at velocities raging from 0.8 km/sec to nearly 7.0 km/sec, as well as fragmented metal projectiles, and a highly conductive carbon plasma. This report deals with the results of those calibration experiments. The data signature study may be used as an aid in the interpretation of the other test data records.
Electronic frequency tuning of the acousto-optic mode-locking device of a laser
NASA Astrophysics Data System (ADS)
Magdich, L. N.; Balakshy, V. I.; Mantsevich, S. N.
2017-11-01
The effect of the electronic tuning of the acoustic resonances in an acousto-optic mode-locking device of a laser is investigated theoretically and experimentally. The problem of the excitation of a Fabry-Perot acoustic resonator by a plate-like piezoelectric transducer (PET) is solved in the approximation of plane acoustic waves taking into consideration the actual parameters of an RF generator and the elements for matching the PET to the generator. Resonances are tuned by changing the matching inductance that was connected in parallel to the transducer of the acousto-optic cell. The cell used in the experiment was manufactured from fused silica and included a lithium niobate PET. Changes in the matching inductance in the range of 0.025 to 0.2 μH provided the acoustic-resonance frequency tuning by 0.19 MHz, which exceeds the acoustic- resonance half-width.
Metallurgical technologies, energy conversion, and magnetohydrodynamic flows
NASA Astrophysics Data System (ADS)
Branover, Herman; Unger, Yeshajahu
The present volume discusses metallurgical applications of MHD, R&D on MHD devices employing liquid working medium for process applications, electromagnetic (EM) modulation of molten metal flow, EM pump performance of superconducting MHD devices, induction EM alkali-metal pumps, a physical model for EM-driven flow in channel-induction furnaces, grain refinement in Al alloys via EM vibrational method, dendrite growth of solidifying metal in dc magnetic field, MHD for mass and heat transfer in single-crystal melt growth, inverse EM shaping, and liquid-metal MHD development in Israel. Also discussed are the embrittlement of steel by lead, an open cycle MHD disk generator, the acceleration of gas-liquid piston flows for molten-metal MHD generators, MHD flow around a cylinder, new MHD drag coefficients, liquid-metal MHD two-phase flow, and two-phase liquid gas mixers for MHD energy conversion. (No individual items are abstracted in this volume)
Zhou, Qi Tony; Tong, Zhenbo; Tang, Patricia; Citterio, Mauro; Yang, Runyu; Chan, Hak-Kim
2013-04-01
The objective of this study is to investigate the effect of device design of the Aerolizer(®) on the aerosolization of a carrier-based dry powder inhaler formulation (Foradile(®)). The Aerolizer was modified by reducing the air inlet size and mouthpiece length to 1/3 of the original dimensions, or by increasing the grid voidage. Aerosolization of the powder formulation was assessed on a multi-stage liquid impinger at air flow rates of 30, 60, and 100 L/min. Coupled CFD-DEM simulations were performed to investigate the air flow pattern and particle impaction. There was no significant difference in the aerosolization behavior between the original and 1/3 mouthpiece length devices. Significant increases in FPF total and FPF emitted were demonstrated when the inlet size was reduced, and the results were explained by the increases in air velocity and turbulence from the CFD analysis. No significant differences were shown in FPF total and FPF emitted when the grid voidage was increased, but more drugs were found to deposit in induction port and to a lesser extent, the mouthpiece. This was supported by the CFD-DEM analysis which showed the particle-device collisions mainly occurred in the inhaler chamber, and the cross-grid design increased the particle-device collisions on both mouthpiece and induction port. The air inlet size and grid structure of the Aerolizer(®) were found to impact significantly on the aerosolization of the carrier-based powder.
NASA Astrophysics Data System (ADS)
Overduin, James; Molloy, Dana; Selway, Jim
2014-03-01
Electromagnetic induction is probably one of the most challenging subjects for students in the introductory physics sequence, especially in algebra-based courses. Yet it is at the heart of many of the devices we rely on today. To help students grasp and retain the concept, we have put together a simple and dramatic classroom demonstration that combines sight and sound with a compelling personal story from U.S. history. Other classroom activities dealing with induction have been discussed in this journal, but we believe that this one will be especially likely to attract and retain student interest, particularly in courses geared toward medical, biological, and other non-physics majors.
NASA Astrophysics Data System (ADS)
Raman, R.; Mueller, D.; Nelson, B. A.; Jarboe, T. R.; Gerhardt, S.; Kugel, H. W.; Leblanc, B.; Maingi, R.; Menard, J.; Ono, M.; Paul, S.; Roquemore, L.; Sabbagh, S.; Soukhanovskii, V.
2010-03-01
Transient coaxial helicity injection (CHI) started discharges in the National Spherical Torus Experiment (NSTX) have attained peak currents up to 300 kA and when coupled to induction, it has produced up to 200 kA additional current over inductive-only operation. CHI in NSTX has shown to be energetically quite efficient, producing a plasma current of about 10 A/J of capacitor bank energy. In addition, for the first time, the CHI-produced toroidal current that couples to induction continues to increase with the energy supplied by the CHI power supply at otherwise similar values of the injector flux, indicating the potential for substantial current generation capability by CHI in NSTX and in future toroidal devices.
Effect of a Second, Parallel Capacitor on the Performance of a Pulse Inductive Plasma Thruster
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Balla, Joseph V.
2010-01-01
Pulsed inductive plasma accelerators are electrodeless space propulsion devices where a capacitor is charged to an initial voltage and is then discharged through an inductive coil that couples energy into the propellant, ionizing and accelerating it to produce thrust. A model that employs a set of circuit equations (as illustrated in Fig. 1a) coupled to a one-dimensional momentum equation has been previously used by Lovberg and Dailey [1] and Polzin et al. [2-4] to model the plasma acceleration process in pulsed inductive thrusters. In this paper an extra capacitor, inductor, and resistor are added to the system in the manner illustrated in the schematic shown in Fig. 1b. If the second capacitor has a smaller value than the initially charged capacitor, it can serve to increase the current rise rate through the inductive coil. Increasing the current rise rate should serve to better ionize the propellant. The equation of motion is solved to find the effect of an increased current rise rate on the acceleration process. We examine the tradeoffs between enhancing the breakdown process (increasing current rise rate) and altering the plasma acceleration process. These results provide insight into the performance of modified circuits in an inductive thruster, revealing how this design permutation can affect an inductive thruster's performance.
Contributions a l'etude et a l'application industrielle de la machine asynchrone
NASA Astrophysics Data System (ADS)
Ouhrouche, Mohand-Ameziane
The work presented in this thesis, done in the Electrical Drives Laboratory of Electrical and Computer Engineering Department, deals with the industrial applications of a three-phase induction machine (electrical drives and electricity generation). This thesis, characterized by its multidisciplinary content, has two major parts. The first one deals with the on-line and off-line parametric identification of the induction machine model necessary to achieve accurate vector control strategy. The second part, which is a resume of a research work sponsored by Hydro-Quebec, deals with the application of an induction machine in Asynchronous Non Utility Generators units (ANUG). As it is shown in the following, major scientific contributions are made in both two parts. In the first part of our research work, we propose a new speed sensorless vector control strategy for an induction machine, which is adaptive to the rotor resistance variations. The proposed control strategy is based on the Extended Kalman Filter approach and a decoupling controller which takes into account the rotor resistance variations. The consideration of coupled electrical and mechanical modes leads to a fifth order nonlinear model of the induction machine. The load torque is taken as a function of the rotor angular speed. The Extended Kalman Filter, based on the process's nonlinear (bilinear) model, estimate simultaneously the rotor resistance, angular speed and the flux vector from the startup to the steady state equilibrium point. The machine-converter-control system is implemented in MATLAB/SIMULINK environment and the obtained results confirm the robustness of the proposed scheme. As in the electrical drives erea, the induction machine is now widely used by small to medium power Non Utility Generator units (NUG) to produce electricity. In Quebec, these NUGs units are integrated into the Hydro-Quebec 25 kV distribution system via transformer which exhibit nonlinear characteristics. We have shown by using the ElectroMagnetic Program (EMTP) that, in some islanding scenarios, i.e. that the NUG unit is disconnected from the power grid, in addition to frequency variations, appearence of high an abnormal overvoltages, ferroresonance should occur. As a consequence, normal protective devices could fail to securely operate, which could cause serious damages to the equipment and the maintenance staff. This result, established for the first time , can be useful to improve the reliability of the NUGs units and is considered important by the power engineering community. This has led to a publication in the John Wiley & Sons Encyclopedia of Electrical and Electronics Engineering which will be available in February 1999 ( http://www.engr.wisc.edu/ ece/ece).
Systematic review: elective induction of labor versus expectant management of pregnancy.
Caughey, Aaron B; Sundaram, Vandana; Kaimal, Anjali J; Gienger, Allison; Cheng, Yvonne W; McDonald, Kathryn M; Shaffer, Brian L; Owens, Douglas K; Bravata, Dena M
2009-08-18
The rates of induction of labor and elective induction of labor are increasing. Whether elective induction of labor improves outcomes or simply leads to greater complications and health care costs is commonly debated in the literature. To compare the benefits and harms of elective induction of labor and expectant management of pregnancy. MEDLINE (through February 2009), Web of Science, CINAHL, Cochrane Central Register of Controlled Trials (through March 2009), bibliographies of included studies, and previous systematic reviews. Experimental and observational studies of elective induction of labor reported in English. Two authors abstracted study design; patient characteristics; quality criteria; and outcomes, including cesarean delivery and maternal and neonatal morbidity. Of 6117 potentially relevant articles, 36 met inclusion criteria: 11 randomized, controlled trials (RCTs) and 25 observational studies. Overall, expectant management of pregnancy was associated with a higher odds ratio (OR) of cesarean delivery than was elective induction of labor (OR, 1.22 [95% CI, 1.07 to 1.39]; absolute risk difference, 1.9 percentage points [CI, 0.2 to 3.7 percentage points]) in 9 RCTs. Women at or beyond 41 completed weeks of gestation who were managed expectantly had a higher risk for cesarean delivery (OR, 1.21 [CI, 1.01 to 1.46]), but this difference was not statistically significant in women at less than 41 completed weeks of gestation (OR, 1.73 [CI, 0.67 to 4.5]). Women who were expectantly managed were more likely to have meconium-stained amniotic fluid than those who were electively induced (OR, 2.04 [CI, 1.34 to 3.09]). There were no recent RCTs of elective induction of labor at less than 41 weeks of gestation. The 2 studies conducted at less than 41 weeks of gestation were of poor quality and were not generalizable to current practice. RCTs suggest that elective induction of labor at 41 weeks of gestation and beyond is associated with a decreased risk for cesarean delivery and meconium-stained amniotic fluid. There are concerns about the translation of these findings into actual practice; thus, future studies should examine elective induction of labor in settings where most obstetric care is provided.
SeleCon: Scalable IoT Device Selection and Control Using Hand Gestures.
Alanwar, Amr; Alzantot, Moustafa; Ho, Bo-Jhang; Martin, Paul; Srivastava, Mani
2017-04-01
Although different interaction modalities have been proposed in the field of human-computer interface (HCI), only a few of these techniques could reach the end users because of scalability and usability issues. Given the popularity and the growing number of IoT devices, selecting one out of many devices becomes a hurdle in a typical smarthome environment. Therefore, an easy-to-learn, scalable, and non-intrusive interaction modality has to be explored. In this paper, we propose a pointing approach to interact with devices, as pointing is arguably a natural way for device selection. We introduce SeleCon for device selection and control which uses an ultra-wideband (UWB) equipped smartwatch. To interact with a device in our system, people can point to the device to select it then draw a hand gesture in the air to specify a control action. To this end, SeleCon employs inertial sensors for pointing gesture detection and a UWB transceiver for identifying the selected device from ranging measurements. Furthermore, SeleCon supports an alphabet of gestures that can be used for controlling the selected devices. We performed our experiment in a 9 m -by-10 m lab space with eight deployed devices. The results demonstrate that SeleCon can achieve 84.5% accuracy for device selection and 97% accuracy for hand gesture recognition. We also show that SeleCon is power efficient to sustain daily use by turning off the UWB transceiver, when a user's wrist is stationary.
SeleCon: Scalable IoT Device Selection and Control Using Hand Gestures
Alanwar, Amr; Alzantot, Moustafa; Ho, Bo-Jhang; Martin, Paul; Srivastava, Mani
2018-01-01
Although different interaction modalities have been proposed in the field of human-computer interface (HCI), only a few of these techniques could reach the end users because of scalability and usability issues. Given the popularity and the growing number of IoT devices, selecting one out of many devices becomes a hurdle in a typical smarthome environment. Therefore, an easy-to-learn, scalable, and non-intrusive interaction modality has to be explored. In this paper, we propose a pointing approach to interact with devices, as pointing is arguably a natural way for device selection. We introduce SeleCon for device selection and control which uses an ultra-wideband (UWB) equipped smartwatch. To interact with a device in our system, people can point to the device to select it then draw a hand gesture in the air to specify a control action. To this end, SeleCon employs inertial sensors for pointing gesture detection and a UWB transceiver for identifying the selected device from ranging measurements. Furthermore, SeleCon supports an alphabet of gestures that can be used for controlling the selected devices. We performed our experiment in a 9m-by-10m lab space with eight deployed devices. The results demonstrate that SeleCon can achieve 84.5% accuracy for device selection and 97% accuracy for hand gesture recognition. We also show that SeleCon is power efficient to sustain daily use by turning off the UWB transceiver, when a user’s wrist is stationary. PMID:29683151
Internal fuse modules for solid tantalum capacitors
NASA Technical Reports Server (NTRS)
Dematos, H. V.
1981-01-01
Miniature fuse modules were designed for and incorporated into two styles of solid tantalum capacitors. One is an epoxy molded, radial leaded, high frequency decoupling capacitor; the other is an hermetically sealed device with axial lead wires. The fusible element for both devices consists of a fine bimetallic wire which reacts exothermically upon reaching a critical temperature and then disintegrates. The desirability of having fused devices is discussed and design constraints, in particular those which minimize inductance and series resistance while optimizing fuse actuation characteristics, are reviewed. Factors affecting the amount of energy required to actuate the fuse and reliability of acuation are identified.
N S Andreasen Struijk, Lotte; Lontis, Eugen R; Gaihede, Michael; Caltenco, Hector A; Lund, Morten Enemark; Schioeler, Henrik; Bentsen, Bo
2017-08-01
Individuals with tetraplegia depend on alternative interfaces in order to control computers and other electronic equipment. Current interfaces are often limited in the number of available control commands, and may compromise the social identity of an individual due to their undesirable appearance. The purpose of this study was to implement an alternative computer interface, which was fully embedded into the oral cavity and which provided multiple control commands. The development of a wireless, intraoral, inductive tongue computer was described. The interface encompassed a 10-key keypad area and a mouse pad area. This system was embedded wirelessly into the oral cavity of the user. The functionality of the system was demonstrated in two tetraplegic individuals and two able-bodied individuals Results: The system was invisible during use and allowed the user to type on a computer using either the keypad area or the mouse pad. The maximal typing rate was 1.8 s for repetitively typing a correct character with the keypad area and 1.4 s for repetitively typing a correct character with the mouse pad area. The results suggest that this inductive tongue computer interface provides an esthetically acceptable and functionally efficient environmental control for a severely disabled user. Implications for Rehabilitation New Design, Implementation and detection methods for intra oral assistive devices. Demonstration of wireless, powering and encapsulation techniques suitable for intra oral embedment of assistive devices. Demonstration of the functionality of a rechargeable and fully embedded intra oral tongue controlled computer input device.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hals, Ingrid K., E-mail: ingrid.hals@ntnu.no; Ogata, Hirotaka; Pettersen, Elin
2012-06-29
Highlights: Black-Right-Pointing-Pointer The impact of UCP-2 over expression on mitochondrial function is controversial. Black-Right-Pointing-Pointer We tested mitochondrial functions at defined levels of overexpression. Black-Right-Pointing-Pointer We find minor increases of fatty acid oxidation and uncoupling. Black-Right-Pointing-Pointer Effects were seen only at high level (fourfold) of over expression. Black-Right-Pointing-Pointer Hence it is doubtful whether these effects are of importance in diabetes. -- Abstract: Evidence is conflicting as to the impact of elevated levels of uncoupling protein-2 (UCP-2) on insulin-producing beta cells. Here we investigated effects of a fourfold induction of UCP-2 protein primarily on mitochondrial parameters and tested for replication of positivemore » findings at a lower level of induction. We transfected INS-1 cells to obtain a tet-on inducible cell line. A 48 h exposure to 1 {mu}g/ml of doxycycline (dox) induced UCP-2 fourfold (424 {+-} 113%, mean {+-} SEM) and 0.1 {mu}g/ml twofold (178 {+-} 29%, n = 3). Fourfold induced cells displayed normal viability (MTT, apoptosis), normal cellular insulin contents and, glucose-induced insulin secretion (+27 {+-} 11%) as well as D-[U-{sup 14}C]-glucose oxidation (+5 {+-} 9% at 11 mM glucose). Oxidation of [1-{sup 14}C]-oleate was increased from 4088 to 5797 fmol/{mu}g prot/2 h at 3.3 mM glucose, p < 0.03. Oxidation of L-[{sup 14}C(U)]-glutamine was unaffected. Induction of UCP-2 did not significantly affect measures of mitochondrial membrane potential (Rhodamine 123) or mitochondrial mass (Mitotracker Green) and did not affect ATP levels. Oligomycin-inhibited oxygen consumption (a measure of mitochondrial uncoupling) was marginally increased, the effect being significant in comparison with dox-only treated cells, p < 0.05. Oxygen radicals, assessed by dichlorofluorescin diacetate, were decreased by 30%, p < 0.025. Testing for the lower level of UCP-2 induction did not reproduce any of the positive findings. A fourfold induction of UCP-2 was required to exert minor metabolic effects. These findings question an impact of moderately elevated UCP-2 levels in beta cells as seen in diabetes.« less
40 CFR 141.100 - Criteria and procedures for public water systems using point-of-entry devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... include physical measurements and observations such as total flow treated and mechanical condition of the... engineering design review of the point-of-entry devices. (2) The design and application of the point-of-entry...
40 CFR 141.100 - Criteria and procedures for public water systems using point-of-entry devices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... include physical measurements and observations such as total flow treated and mechanical condition of the... engineering design review of the point-of-entry devices. (2) The design and application of the point-of-entry...
40 CFR 141.100 - Criteria and procedures for public water systems using point-of-entry devices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... include physical measurements and observations such as total flow treated and mechanical condition of the... engineering design review of the point-of-entry devices. (2) The design and application of the point-of-entry...
Spates, J.J.; Martin, S.J.; Mansure, A.J.
1997-08-26
An acoustic-wave sensor apparatus and method are disclosed. The apparatus for analyzing a normally liquid petroleum-based composition includes at least one acoustic-wave device in contact with the petroleum-based composition for sensing or detecting the presence of constituents (e.g. paraffins or petroleum waxes) therein which solidify upon cooling of the petroleum-based composition below a cloud-point temperature. The acoustic-wave device can be a thickness-shear-mode device (also termed a quartz crystal microbalance), a surface-acoustic-wave device, an acoustic-plate-mode device or a flexural plate-wave device. Embodiments of the present invention can be used for measuring a cloud point, a pour point and/or a freeze point of the petroleum-based composition, and for determining a temperature characteristic of each point. Furthermore, measurements with the acoustic-wave sensor apparatus can be made off-line by using a sample having a particular petroleum-based composition; or in-situ with the petroleum-based composition contained within a pipeline or storage tank. The acoustic-wave sensor apparatus has uses in many different petroleum technology areas, including the recovery, transport, storage, refining and use of petroleum and petroleum-based products. 7 figs.
Spates, James J.; Martin, Stephen J.; Mansure, Arthur J.
1997-01-01
An acoustic-wave sensor apparatus and method. The apparatus for analyzing a normally liquid petroleum-based composition includes at least one acoustic-wave device in contact with the petroleum-based composition for sensing or detecting the presence of constituents (e.g. paraffins or petroleum waxes) therein which solidify upon cooling of the petroleum-based composition below a cloud-point temperature. The acoustic-wave device can be a thickness-shear-mode device (also termed a quartz crystal mircrobalance), a surface-acoustic-wave device, an acoustic-plate-mode device or a flexural plate-wave device. Embodiments of the present invention can be used for measuring a cloud point, a pour point and/or a freeze point of the petroleum-based composition, and for determining a temperature characteristic of each point. Furthermore, measurements with the acoustic-wave sensor apparatus can be made off-line by using a sample having a particular petroleum-based composition; or in-situ with the petroleum-based composition contained within a pipeline or storage tank. The acoustic-wave sensor apparatus has uses in many different petroleum technology areas, including the recover transport, storage, refining and use of petroleum and petroleum-based products.
Koelle, A.R.; Landt, J.A.
An instrument is disclosed for mapping vertical conductive fractures in a resistive bedrock, magnetically inducing eddy currents by a pair of vertically oriented, mutually perpendicular, coplanar coils. The eddy currents drive magnetic fields which are picked up by a second, similar pair of coils.
NASA Astrophysics Data System (ADS)
McAlexander, Aaron
2005-12-01
This is a description of an inexpensive version of the Thompson's jumping ring demonstration apparatus, which provides for a spectacular demonstration of Lenz's law. The device has the additional capability of being used to demonstrate the opposing nature of inductive and capacitive reactance.
NASA Technical Reports Server (NTRS)
Gardner, W. C.
1973-01-01
Connector pair consists of two iron cores brought together a short distance from each other. Each core is wound with insulated wire. Ac signal is connected through the pair across the gap by magnetic induction. Device can be used underwater or in flammable atmosphere.
40 CFR 142.57 - Bottled water, point-of-use, and point-of-entry devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Bottled water, point-of-use, and point-of-entry devices. 142.57 Section 142.57 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS IMPLEMENTATION Exemptions Issued by the Administrator § 142.57...
Risk-Taking Propensity as a Predictor of Induction onto Naltrexone Treatment for Opioid Dependence
Aklin, Will M.; Severtson, S. Geoffrey; Umbricht, Annie; Fingerhood, Michael; Bigelow, George E.; Lejuez, C. W.; Silverman, Kenneth
2014-01-01
Objective Heroin addiction is a chronic relapsing disorder that has devastating social, medical, and economic consequences. Naltrexone is an antagonist that blocks opioid effects and could be an effective medication for the treatment of opioid dependence. However, its clinical utility has been limited partly because of poor adherence and acceptability. Given the importance of compliance to naltrexone treatment for opioid dependence, the goal of the current study was to examine predictors involved in successful induction onto naltrexone treatment. Method Parametric and nonparametric statistical tests were performed on data from a sample of 64 individuals entering treatment who met DSM-IV criteria for opioid dependence. The relationship between naltrexone induction (i.e., inducted- vs. not-inducted onto naltrexone) and risk-taking propensity, as indexed by riskiness on the Balloon Analogue Risk Task (BART) was examined. Participants were recruited from local detoxification programs, inpatient drug treatment, and other Baltimore programs that provided services to opioid dependent adults (e.g., Baltimore Needle Exchange Program) during the period from August 2007 to September 2008. Results Positive association between risk-taking propensity and odds of naltrexone induction. Specifically, each five point increase in the total BART score was associated with a 25% decrease in odds of naltrexone induction (OR=0.76, 95% CI: 0.58–0.99, p = .041). This association remained statistically significant even after adjusting for potential confounds, including injection drug use and cocaine positive urine results (p = .05). After adjusting for the covariates, each five point increase in BART score was associated with 28% decrease in the odds of achieving the maintenance dose (AOR=0.73, 95% CI: 0.54–0.99, p = .046). Conclusions Risk taking propensity was predictive of induction onto naltrexone treatment, above and beyond injection drug use and cocaine-positive urine samples. PMID:22967782
Research on the method of establishing the total radiation meter calibration device
NASA Astrophysics Data System (ADS)
Gao, Jianqiang; Xia, Ming; Xia, Junwen; Zhang, Dong
2015-10-01
Pyranometer is an instrument used to measure the solar radiation, according to pyranometer differs as installation state, can be respectively measured total solar radiation, reflected radiation, or with the help of shading device for measuring scattering radiation. Pyranometer uses the principle of thermoelectric effect, inductive element adopts winding plating type multi junction thermopile, its surface is coated with black coating with high absorption rate. Hot junction in the induction surface, while the cold junction is located in the body, the cold and hot junction produce thermoelectric potential. In the linear range, the output signal is proportional to the solar irradiance. Traceability to national meteorological station, as the unit of the national legal metrology organizations, the responsibility is to transfer value of the sun and the earth radiation value about the national meteorological industry. Using the method of comparison, with indoor calibration of solar simulator, at the same location, standard pyranometer and measured pyranometer were alternately measured radiation irradiance, depending on the irradiation sensitivity standard pyranometer were calculated the radiation sensitivity of measured pyranometer. This paper is mainly about the design and calibration method of the pyranometer indoor device. The uncertainty of the calibration result is also evaluated.
Qubit-Based Memcapacitors and Meminductors
NASA Astrophysics Data System (ADS)
Shevchenko, Sergey N.; Pershin, Yuriy V.; Nori, Franco
2016-07-01
It is shown that superconducting charge and flux quantum bits (qubits) can be classified as memory capacitive and inductive systems, respectively. We demonstrate that such memcapacitive and meminductive devices offer remarkable and rich response functionalities. In particular, when subjected to periodic input, qubit-based memcapacitors and meminductors exhibit unusual hysteresis curves. Our work not only extends the set of known memcapacitive and meminductive systems to qubit-based devices, but also highlights their unique properties potentially useful for future technological applications.
The multipole resonance probe: characterization of a prototype
NASA Astrophysics Data System (ADS)
Lapke, Martin; Oberrath, Jens; Schulz, Christian; Storch, Robert; Styrnoll, Tim; Zietz, Christian; Awakowicz, Peter; Brinkmann, Ralf Peter; Musch, Thomas; Mussenbrock, Thomas; Rolfes, Ilona
2011-08-01
The multipole resonance probe (MRP) was recently proposed as an economical and industry compatible plasma diagnostic device (Lapke et al 2008 Appl. Phys. Lett. 93 051502). This communication reports the experimental characterization of a first MRP prototype in an inductively coupled argon/nitrogen plasma at 10 Pa. The behavior of the device follows the predictions of both an analytical model and a numerical simulation. The obtained electron densities are in excellent agreement with the results of Langmuir probe measurements.
Connections between Transcription Downstream of Genes and cis-SAGe Chimeric RNA.
Chwalenia, Katarzyna; Qin, Fujun; Singh, Sandeep; Tangtrongstittikul, Panjapon; Li, Hui
2017-11-22
cis-Splicing between adjacent genes (cis-SAGe) is being recognized as one way to produce chimeric fusion RNAs. However, its detail mechanism is not clear. Recent study revealed induction of transcriptions downstream of genes (DoGs) under osmotic stress. Here, we investigated the influence of osmotic stress on cis-SAGe chimeric RNAs and their connection to DoGs. We found,the absence of induction of at least some cis-SAGe fusions and/or their corresponding DoGs at early time point(s). In fact, these DoGs and their cis-SAGe fusions are inversely correlated. This negative correlation was changed to positive at a later time point. These results suggest a direct competition between the two categories of transcripts when total pool of readthrough transcripts is limited at an early time point. At a later time point, DoGs and corresponding cis-SAGe fusions are both induced, indicating that total readthrough transcripts become more abundant. Finally, we observed overall enhancement of cis-SAGe chimeric RNAs in KCl-treated samples by RNA-Seq analysis.
Performance optimization of a hybrid micro-grid based on double-loop MPPT and SVC-MERS
NASA Astrophysics Data System (ADS)
Wei, Yewen; Hou, Xilun; Zhang, Xiang; Xiong, Shengnan; Peng, Fei
2018-02-01
With ever-increasing concerns on environmental pollution and energy shortage, the development of renewable resource has attracted a lot of attention. This paper first reviews both the wind and photovoltaic (PV) generation techniques and approaches of micro-grid voltage control. Then, a novel islanded micro-grid, which consists of wind & PV generation and hybrid-energy storage device, is built for application to remote and isolated areas. For the PV power generation branch, a double- maximum power point tracking (MPPT) technique is developed to trace the sunlight and regulate the tilt angle of PV panels. For wind-power generation branch, squirrel cage induction generator (SCIG) is used as its simple structure, robustness and less cost. In order to stabilize the output voltage of SCIGs, a new Static Var Compensator named magnetic energy recovery switch (SVC-MERS) is applied. Finally, experimental results confirm that both of the proposed methods can improve the efficiency of PV power generation and voltage stability of the micro-grid, respectively.
Fabrication and characterization of iron oxide ceramic membranes for arsenic removal.
Sabbatini, P; Yrazu, F; Rossi, F; Thern, G; Marajofsky, A; Fidalgo de Cortalezzi, M M
2010-11-01
Nanoscale iron oxide particles were synthesized and deposited on porous alumina tubes to develop tubular ceramic adsorbers for the removal of arsenic, which is an extremely toxic contaminant even in very low concentrations. Its natural presence affects rural and low-income populations in developing countries in Latin America and around the world, which makes it essential to develop a user-friendly, low energy demanding and low cost treatment technology. The fabricated ceramic membranes can be operated with minimal trans-membrane pressure difference and do not require pumping. The support tubes and final membrane have been characterized by surface area and porosity measurements, permeability tests and scanning electron microscopy (SEM) imaging. Arsenic concentrations were determined by inductively coupled plasma-optical emission spectroscopy (ICP-OES). Due to its low cost and simple operation, the system can be applied as a point of use device for the treatment of arsenic contaminated groundwaters in developing countries. Copyright © 2010 Elsevier Ltd. All rights reserved.
Batteryless implanted echosonometer
NASA Technical Reports Server (NTRS)
Kojima, G. K.
1977-01-01
Miniature ultrasonic echosonometer implanted within laboratory animals obtains energy from RF power oscillator that is electronically transduced via induction loop to power receiving loop located just under animal's skin. Method of powering device offers significant advantages over those in which battery is part of implanted package.
Microwave dynamics of high aspect ratio superconducting nanowires studied using self-resonance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santavicca, Daniel F., E-mail: daniel.santavicca@unf.edu; Adams, Jesse K.; Grant, Lierd E.
2016-06-21
We study the microwave impedance of extremely high aspect ratio (length/width ≈ 5000) superconducting niobium nitride nanowires. The nanowires are fabricated in a compact meander geometry that is in series with the center conductor of a 50 Ω coplanar waveguide transmission line. The transmission coefficient of the sample is measured up to 20 GHz. At high frequency, a peak in the transmission coefficient is seen. Numerical simulations show that this is a half-wave resonance along the length of the nanowire, where the nanowire acts as a high impedance, slow wave transmission line. This resonance sets the upper frequency limit for these nanowires asmore » inductive elements. Fitting simulations to the measured resonance enables a precise determination of the nanowire's complex sheet impedance at the resonance frequency. The real part is a measure of dissipation, while the imaginary part is dominated by kinetic inductance. We characterize the dependence of the sheet resistance and sheet inductance on both temperature and current and compare the results to recent theoretical predictions for disordered superconductors. These results can aid in the understanding of high frequency devices based on superconducting nanowires. They may also lead to the development of novel superconducting devices such as ultra-compact resonators and slow-wave structures.« less
Wireless power and data transmission strategies for next-generation capsule endoscopes
NASA Astrophysics Data System (ADS)
Puers, R.; Carta, R.; Thoné, J.
2011-05-01
Capsular endoscopy is becoming increasingly popular as an alternative to traditional gastro-intestinal (GI) examination techniques. However, the breakthrough of these devices is hindered by the limited amount of power that can be stored in a tiny pill. Most commercial devices use two watch batteries that can only provide an average power of 25 mW for about 6 h, certainly not sufficient for advanced robotic features. A dedicated inductive powering system, operating at 1 MHz to limit the human body absorption, has been developed which was proven to support the transfer of over 300 mW. The system relies on a condensed set of orthogonal ferrite coils, embedded in the capsule, and an external unit based on a Helmholtz coil driven by a class E amplifier. Control data can be sent through the inductive link by modulating the power carrier, whereas a dedicated high data rate RF link is used to transfer the images from the capsule to the base station. Besides evaluating the compatibility with radio transmission, several demonstrators were assembled combining the wireless powering system with various locomotion strategies and LED illumination. This paper describes the design and implementation of the inductive powering system, its combination with data transmission techniques and the testing activity with other capsule-dedicated modules.
Kalchofner Guerrero, Karin S; Reichler, Iris M; Schwarz, Andrea; Jud, Rahel S; Hässig, Michael; Bettschart-Wolfensberger, Regula
2014-11-01
To compare post-operative pain in cats after alfaxalone or ketamine- medetomidine anaesthesia for ovariohysterectomy (OHE) and physiologic parameters during and after surgery. Prospective 'blinded' randomized clinical study. Twenty-one healthy cats. Cats were assigned randomly into two groups: Group A, anaesthesia was induced and maintained with alfaxalone [5 mg kg(-1) intravenously (IV) followed by boli (2 mg kg(-1) IV); Group MK, induction with ketamine (5 mg kg(-1) IV) after medetomidine (30 μg kg(-1) intramuscularly (IM)], and maintenance with ketamine (2 mg kg(-1) IV). Meloxicam (0.2 mg kg(-1) IV) was administered after surgery. Basic physiological data were collected. At time T = -2, 0, 0.5, 1, 2, 4, 6, 8, 12, 16, 20, and 24 hours post-operatively pain was assessed by three methods, a composite pain scale (CPS; 0-24 points), a visual analogue scale (VAS 0-100 mm), and a mechanical wound threshold (MWT) device. Butorphanol (0.2 mg kg(-1) IM) was administered if CPS was scored ≥13. Data were analyzed using a general linear model, Kruskal-Wallis analyses, Bonferroni-Dunn test, unpaired t-test and Fisher's exact test as relevant. Significance was set at p < 0.05. VASs were significantly higher at 0.5, 1, 2, 4, and 20 hours in group A; MWT values were significantly higher at 8 and 12 hours in group MK. Post-operative MWT decreased significantly compared to baseline in both groups. There was no difference in CPS at any time point. Five cats required rescue analgesia (four in A; one in MK). Anaesthesia with ketamine-medetomidine was found to provide better post-surgical analgesia than alfaxalone in cats undergoing OHE; however, primary hyperalgesia developed in both groups. Alfaxalone is suitable for induction and maintenance of anaesthesia in cats undergoing OHE, but administration of additional sedative and analgesic drugs is highly recommended. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.
Zhou, Yu-Xun; Cao, Wei; Wei, Dong-Zhi; Luo, Qing-Ping; Wang, Jin-Zhi
2005-07-01
33 amino acid antibiotic peptide adenoregulin (ADR), which were firstly isolated from the skin of South America arboreal frog Phyllomedusa bicolor, forms alpha-helix amphipathic structure in apolar medium and has a wide spectrum of antimicrobial activity and high potency of lytic ability. Adr gene was cloned in pET32a and transformed into Escherichia coli BL21(DE3) . The cultural and inductive conditions of E. coli BL21(DE3)/pET32a-adr have been optimized. The effect of three factors which were time point of induction, concentration of IPTG in the culture and time of induction on the expression level of Trx-ADR was investigated. The results indicated that the expression level was affected by the time point of induction most predominantly. 9 veriaties of media in which BL21 (DE3)/pET32a-adr was cultured and induced were tested to achieve high expression level of target protein. It was found that glucose in the medium played an important role in keeping stable and high expression level of Trx-ADR. The optimal inductive condition is as follows: the culture medium is 2 x YT + 0.5% glucose, the time point of induction is OD600 = 0.9, the final concentration of IPTG in the culture is 0.1 mmol/L and the induction time is 4 h. BL21 (DE3)/pET32a-adr was cultivated according to the strategy of constant pH at early stage and exponential feeding at later stage to obtain high cell density. During the entire fed-batch phase, by controlling the feeding of glucose, the specific growth rate of the culture was controlled at about 0.15 h(-1), the accumulation of acetic acid was controlled at low level (<2 g/L), but the plasmid stability could not be maintained well. At the end of the cultivation, 40% of the bacteria in the culture lost their plasmids. As a result, the expression level of the target protein declined dramatically, but 90% of Trx-ADR was in soluble form. The expressed fusion protein showed no antibacterial activity, while the native form of ADR lysed from Trx-ADR showed distinct antibacterial activity.
Code of Federal Regulations, 2013 CFR
2013-07-01
... oxidation control device or at the exhaust point from the combustion chamber of a thermal oxidation control... scrubber achieves at least 99-percent control of ethylene oxide emissions. Oxidation temperature means the temperature at the outlet point of a catalytic oxidation unit control device or at the exhaust point from the...
Inductance parameter design based seamless transfer strategy for three-phase converter in microgrid
NASA Astrophysics Data System (ADS)
Zhao, Guopeng; Zhou, Xinwei; Jiang, Chao; Lu, Yi; Wang, Yanjie
2018-06-01
During the operation of microgrid, especially when the unplanned islanding occurs, the voltage of the point of common coupling (PCC) needs to be maintained within a certain range, otherwise it would affect the operation of loads in microgrid. This paper proposes a seamless transfer strategy based on the inductance parameter design for three-phase converter in microgrid, which considers both the fundamental component of voltage on the inductance and the ripple current in the inductance. In grid-connected mode, the PCC voltage is supported by the grid. When the unplanned islanding occurs, the PCC voltage is affected by the output voltage of converter and the voltage on the inductance. According to the single phase equivalent circuit, analyzing the phasor diagram of voltage and current vector, considering the prescribed range of PCC voltage and satisfying the requirement of the magnitude of ripple current, the inductance parameter is designed. At last, the simulation result shows that the designed inductance can ensure the PCC voltage does not exceed the prescribed range and restrain the ripple current.
NASA Astrophysics Data System (ADS)
Thiesson, Julien; Rousselle, Gabrielle; Simon, François Xavier; Tabbagh, Alain
2011-12-01
Electromagnetic induction (EMI) is one of the geophysical techniques widely used in soil studies, the slingram devices being held horizontally over the soil surface, i.e. with the coils located at the same height above the ground surface. Our study aims assessing the abilities of slingram devices when held vertically. 1D and 3D modelling have been achieved in order to compare the theoretical responses of vertical devices to the horizontal ones. Some comparative surveys were also undertaken in archaeological contexts to confirm the reliability of theoretical conclusions. Both approaches show that vertical slingram devices are suitable for survey and can constitute an alternative to the usual horizontal orientation. We give a table in Appendix A which contains the calibration coefficient allowing transforming of the values given by some of commercially available devices which would be advantageous to use in vertical orientation
Stepwise renal lineage differentiation of mouse embryonic stem cells tracing in vivo development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nishikawa, Masaki, E-mail: masakiwestriver@gmail.com; University of California at Los Angeles, David Geffen School of Medicine, Los Angeles, CA 91343; Yanagawa, Naomi
2012-01-13
Highlights: Black-Right-Pointing-Pointer We induced renal lineages from mESCs by following the in vivo developmental cues. Black-Right-Pointing-Pointer We induced nephrogenic intermediate mesoderm by stepwise addition of factors. Black-Right-Pointing-Pointer We induced two types of renal progenitor cells by reciprocal conditioned media. Black-Right-Pointing-Pointer We propose the potential role of CD24 for the enrichment of renal lineage cells. -- Abstract: The in vitro derivation of renal lineage progenitor cells is essential for renal cell therapy and regeneration. Despite extensive studies in the past, a protocol for renal lineage induction from embryonic stem cells remains unestablished. In this study, we aimed to induce renal lineagesmore » from mouse embryonic stem cells (mESC) by following in vivo developmental stages, i.e., the induction of mesoderm (Stage I), intermediate mesoderm (Stage II) and renal lineages (Stage III). For stage I induction, in accordance with known signaling pathways involved in mesoderm development in vivo, i.e., Nodal, bone morphogenic proteins (BMPs) and Wnt, we found that the sequential addition of three factors, i.e., Activin-A (A), a surrogate for Nodal signaling, during days 0-2, A plus BMP-4 (4) during days 2-4, and A4 plus lithium (L), a surrogate for Wnt signaling, during days 4-6, was most effective to induce the mesodermal marker, Brachyury. For stage II induction, the addition of retinoic acid (R) in the continuous presence of A4L during days 6-8 was most effective to induce nephrogenic intermediate mesodermal markers, such as Pax2 and Lim1. Under this condition, more than 30% of cells were stained positive for Pax2, and there was a concomitant decrease in the expression of non-mesodermal markers. For stage III induction, in resemblance to the reciprocal induction between ureteric bud (UB) and metanephric mesenchyme (MM) during kidney development, we found that the exposure to conditioned media derived from UB and MM cells was effective in inducing MM and UB markers, respectively. We also observed the emergence and gradual increase of cell populations expressing progenitor cell marker CD24 from Stage I to Stage III. These CD24{sup +} cells correlated with higher levels of expression of Brachyury at stage I, Pax2 and Lim1 at stage II and MM markers, such as WT1 and Cadherin 11, after exposure to UB-conditioned media at stage III. In conclusion, our results show that stepwise induction by tracing in vivo developmental stages was effective to generate renal lineage progenitor cells from mESC, and CD24 may serve as a useful surface marker for renal lineage cells at stage II and MM cells at stage III.« less
NASA Astrophysics Data System (ADS)
Siqueira, Glecio; Silva, Jucicléia; Bezerra, Joel; Silva, Enio; Montenegro, Abelardo
2013-04-01
The cultivation of sugar cane in Brazil occupies a prominent place in national production chain, because the country is the main world producer of sugar and ethanol. Accordingly, studies are needed that allow an integrated production and technified, and especially that estimates of crops are consistent with the actual production of each region. The objective of this study was to determine the spatial relationship between the productivity of cane sugar and soil electrical conductivity measured by electromagnetic induction. The field experiment was conducted at an agricultural research site located in Goiana municipality, Pernambuco State, north-east of Brazil (Latitude 07 ° 34 '25 "S, Longitude 34 ° 55' 39" W). The surface of the studied field is 6.5 ha, and its mean height 8.5 m a.s.l. This site has been under sugarcane (Saccharum officinarum sp.) monoculture during the last 24 years and it was managed burning the straw each year after harvesting, renewal of plantation was performed every 7 years. Studied the field is located 10 km east from Atlantic Ocean and it is representative of the regional landscape lowlands, whose soils are affected by salinity seawater, sugarcane plantations with the main economical activity. Soil was classified an orthic the Podsol. The productivity of cane sugar and electrical conductivity were measured in 90 sampling points. The productivity of cane sugar was determined in each of the sampling points in plots of 9 m2. The Apparent soil electrical conductivity (ECa, mS m-1) was measured with an electromagnetic induction device EM38-DD (Geonics Limited). The equipment consists of two units of measurement, one in a horizontal dipole (ECa-H) to provide effective measurement distance of 1.5 m approximately and other one in vertical dipole (ECa-V) with an effective measurement depth of approximately 0.75 m. Data were analyzed using descriptive statistics and geostatistical tools. The results showed that productivity in the study area reached values above 200 t ha-1, with higher values of productivity are concentrated in the region northern terrain. The maps of soil electrical conductivity (ECa-V and ECa-H) showed behavior similar to the productivity of cane sugar. The linear correlation showed values of 0.74 (yield x ECa-H) and 0.85 (yield x ECa-V). The adjusted semivariograms showed no similarity in the spatial pattern of pairs of semivariance. The electrical conductivity measured by electromagnetic induction has been shown as an important tool for predicting the productivity of sugar cane, however more studies are needed to determine the magnitude of the differences between such attributes.
Energy Device Applications of Synthesized 1D Polymer Nanomaterials.
Huang, Long-Biao; Xu, Wei; Hao, Jianhua
2017-11-01
1D polymer nanomaterials as emerging materials, such as nanowires, nanotubes, and nanopillars, have attracted extensive attention in academia and industry. The distinctive, various, and tunable structures in the nanoscale of 1D polymer nanomaterials present nanointerfaces, high surface-to-volume ratio, and large surface area, which can improve the performance of energy devices. In this review, representative fabrication techniques of 1D polymer nanomaterials are summarized, including electrospinning, template-assisted, template-free, and inductively coupled plasma methods. The recent advancements of 1D polymer nanomaterials in energy device applications are demonstrated. Lastly, existing challenges and prospects of 1D polymer nanomaterials for energy device applications are presented. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Super-Alfvénic translation of a field-reversed configuration into a large-bore dielectric chamber
NASA Astrophysics Data System (ADS)
Sekiguchi, J.; Asai, T.; Takahashi, T.
2018-01-01
An experimental device to demonstrate additional heating and control methods for a field-reversed configuration (FRC) has been developed. The newly developed device, named FRC Amplification via Translation (FAT), has a field-reversed theta-pinch plasma source and a low-elongation dielectric (transparent quartz) confinement chamber with quasi-static confinement field. In the initial experiments on the FAT device, FRC translation and trapping were successfully demonstrated. Although the typical elongation of the trapped FRC in the confinement region was roughly three, no disruptive global instability, such as tilt, was observed. The FAT device increases the latitude to perform translation-related experiments, such as those concerning inductive current drive, equivalent neutral beam injection effects, and wave applications.
Piezoelectric devices for generating low power
NASA Astrophysics Data System (ADS)
Chilibon, Irinela
2016-12-01
This paper reviews concepts and applications in low-power electronics and energy harvesting technologies. Various piezoelectric materials and devices for small power generators useful in renewable electricity are presented. The vibrating piezoelectric device differs from the typical electrical power source in that it has capacitive rather than inductive source impedance, and may be driven by mechanical vibrations of varying amplitude. In general, vibration energy could be converted into electrical energy using one of three techniques: electrostatic charge, magnetic fields and piezoelectric. A low power piezoelectric generator, having a PZT element was realised in order to supply small electronic elements, such as optoelectronic small devices, LEDs, electronic watches, small sensors, interferometry with lasers or Micro-electro-mechanical System (MEMS) array with multi-cantilevers.
Stable Spheromaks Sustained by Neutral Beam Injection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fowler, T K; Jayakumar, R; McLean, H S
It is shown that spheromak equilibria, stable at zero-beta but departing from the Taylor state, could be sustained by non-inductive current drive at acceptable power levels. Stability to both ideal MHD and tearing modes is verified using the NIMROD code for linear stability analysis. Non-linear NIMROD calculations with non-inductive current drive and pressure effects could point the way to improved fusion reactors.
Voltage oriented control of self-excited induction generator for wind energy system with MPPT
NASA Astrophysics Data System (ADS)
Amieur, Toufik; Taibi, Djamel; Amieur, Oualid
2018-05-01
This paper presents the study and simulation of the self-excited induction generator in the wind power production in isolated sites. With this intention, a model of the wind turbine was established. Extremum-seeking control algorithm method by using Maximum Power Point Tracking (MPPT) is proposed control solution aims at driving the average position of the operating point near to optimality. The reference of turbine rotor speed is adjusted such that the turbine operates around maximum power for the current wind speed value. After a brief review of the concepts of converting wind energy into electrical energy. The proposed modeling tools were developed to study the performance of standalone induction generators connected to capacitor bank. The purpose of this technique is to maintain a constant voltage at the output of the rectifier whatever the loads and speeds. The system studied in this work is developed and tested in MATLAB/Simulink environment. Simulation results validate the performance and effectiveness of the proposed control methods.
Fluctuation dynamo and turbulent induction at small Prandtl number.
Eyink, Gregory L
2010-10-01
We study the Lagrangian mechanism of the fluctuation dynamo at zero Prandtl number and infinite magnetic Reynolds number, in the Kazantsev-Kraichnan model of white-noise advection. With a rough velocity field corresponding to a turbulent inertial range, flux freezing holds only in a stochastic sense. We show that field lines arriving to the same point which were initially separated by many resistive lengths are important to the dynamo. Magnetic vectors of the seed field that point parallel to the initial separation vector arrive anticorrelated and produce an "antidynamo" effect. We also study the problem of "magnetic induction" of a spatially uniform seed field. We find no essential distinction between this process and fluctuation dynamo, both producing the same growth rates and small-scale magnetic correlations. In the regime of very rough velocity fields where fluctuation dynamo fails, we obtain the induced magnetic energy spectra. We use these results to evaluate theories proposed for magnetic spectra in laboratory experiments of turbulent induction.
Induction of depressed mood: a test of opponent-process theory.
Ranieri, D J; Zeiss, A M
1984-12-01
Solomon's (1980) opponent-process theory of acquired motivation has been used to explain many phenomena in which affective or hedonic contrasts appear to exist, but has not been applied to the induction of depressed mood. The purpose of this study, therefore, was to determine whether opponent-process theory can be applied to this area. Velten's (1968) mood-induction procedure was used and subjects were assigned either to a depression-induction condition or to one of two control groups. Self-report measures of depressed mood were taken before, during, and at several points after the mood induction. Results were not totally consistent with a rigorous set of criteria for supporting an opponent-process interpretation. This suggests that the opponent-process model may not be applicable to induced depressed mood. Possible weaknesses in the experimental design, along with implications for opponent-process theory, are discussed.
Women's experiences of outpatient induction of labour with remote continuous monitoring.
O'Brien, Ediri; Rauf, Zubair; Alfirevic, Zarko; Lavender, Tina
2013-04-01
to gain insight into women's experiences and preferences for induction in the home as part of a trial investigating the feasibility and acceptability of outpatient induction of labour with remote monitoring. a qualitative study using semi-structured individual interviews. Interview transcripts were subjected to thematic analysis to identify the dominant themes regarding women's experiences of outpatient induction. a large maternity hospital in the North West of England. fifteen women who participated in the main trial of outpatient induction of labour with remote continuous monitoring. three main themes were identified; the need for women to 'labour within their comfort zone'; their desire to achieve 'the next best thing to a normal labour' and the importance of a 'virtual presence' to offer remote reassurance. women's preference for the outpatient setting of induction of labour is dominated by their need to labour within their comfort zone. Outpatient induction offered women the familiarity and freedom of the home environment, and the resulting physical and emotional comforts helped women cope better with their labour and improved their birth experiences. While remote monitoring offered some reassurance, women still depended on effective communication from hospital staff to provide the virtual presence of a health professional in the home. the combination of slow-release prostaglandin and a remote monitoring device may provide low risk women with an improved induction and labour experience. While ongoing studies continue to explore further the safety of interventions at home, this study has importantly considered women's views and confirmed that induction at home is not only acceptable to women but also that the outpatient experience is preferable to long inpatient inductions. Copyright © 2012 Elsevier Ltd. All rights reserved.
Band-Pass Amplifier Without Discrete Reactance Elements
NASA Technical Reports Server (NTRS)
Kleinberg, L.
1984-01-01
Inherent or "natural" device capacitance exploited. Band-Pass Circuit has input impedance of equivalent circuit at frequencies much greater than operational-amplifier rolloff frequency. Apparent inductance and capacitance arise from combined effects of feedback and reactive component of amplifier gain in frequency range.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coteus, Paul W.; Ferencz, Andrew; Hall, Shawn A.
An apparatus includes a first circuit board including first components including a load, and a second circuit board including second components including switching power devices and an output inductor. Ground and output voltage contacts between the circuit boards are made through soldered or connectorized interfaces. Certain components on the first circuit board and certain components, including the output inductor, on the second circuit board act as a DC-DC voltage converter for the load. An output capacitance for the conversion is on the first circuit board with no board-to-board interface between the output capacitance and the load. The inductance of themore » board-to-board interface functions as part of the output inductor's inductance and not as a parasitic inductance. Sense components for sensing current through the output inductor are located on the first circuit board. Parasitic inductance of the board-to-board interface has less effect on a sense signal provided to a controller.« less
Moser, Barry; Stock, Wendy; Gallagher, Robert E.; Willman, Cheryl L.; Stone, Richard M.; Rowe, Jacob M.; Coutre, Steven; Feusner, James H.; Gregory, John; Couban, Stephen; Appelbaum, Frederick R.; Tallman, Martin S.; Larson, Richard A.
2010-01-01
Arsenic trioxide (As2O3) is a highly effective treatment for patients with relapsed acute promyelocytic leukemia (APL); its role as consolidation treatment for patients in first remission has not been defined. We randomized 481 patients (age ≥ 15 years) with untreated APL to either a standard induction regimen of tretinoin, cytarabine, and daunorubicin, followed by 2 courses of consolidation therapy with tretinoin plus daunorubicin, or to the same induction and consolidation regimen plus two 25-day courses of As2O3 consolidation immediately after induction. After consolidation, patients were randomly assigned to one year of maintenance therapy with either tretinoin alone or in combination with methotrexate and mercaptopurine. Ninety percent of patients on each arm achieved remission and were eligible to receive their assigned consolidation therapy. Event-free survival, the primary end point, was significantly better for patients assigned to receive As2O3 consolidation, 80% compared with 63% at 3 years (stratified log-rank test, P < .0001). Survival, a secondary end point, was better in the As2O3 arm, 86% compared with 81% at 3 years (P = .059). Disease-free survival, a secondary end point, was significantly better in the As2O3 arm, 90% compared with 70% at 3 years (P < .0001). The addition of As2O3 consolidation to standard induction and consolidation therapy significantly improves event-free and disease-free survival in adults with newly diagnosed APL. This trial was registered at clinicaltrials.gov (NCT00003934). PMID:20705755
Standardizing therapeutic parameters of acupuncture for pain suppression in rats: preliminary study.
Yeo, Sujung; Lim, Hyungtaeck; Choe, Ilwhan; Kim, Sung-Hoon; Lim, Sabina
2014-01-15
Despite acupuncture's wide and successful use, it is still considered as lacking scientifically rigorous evidence, especially with respect to its effectiveness. To address this problem, it is necessary to re-examine the practice of acupuncture using scientific methodology. The standardization of acupuncture practices may offer a solution. As a preliminary step towards the standardization of acupuncture stimulation in animal experiments, this study attempted to clarify the various therapeutic parameters that contribute to acupuncture's efficacy. This study identified specific acupoints, temporal point of needling, rotation of the needle, duration of acupuncture, and diameter of the needle as the parameters, through formalin test. In this test, acupuncture was performed on either the ST36 or LR2 point immediately after pain induction and 5 minutes after pain induction. The formalin test yielded no significant suppression of pain in the case of ST36 and LR2 acupuncture stimulation immediately following pain induction. When acupuncture was applied 5 minutes after pain induction, however, the ST36 stimulation resulted in a significant decrease in pain, while the LR2 stimulation produced no change. The duration of acupuncture, but not the diameter of the needle, was also significant. As for the rotation of the needle, there was no significant difference in the pain reduction achieved in the rotation and non-rotation groups. We determined that specific acupoint, temporal point of needling, and duration of treatment are important factors in the inhibition of pain. These finding strongly suggest that in animal experiments, the application of a set of appropriate therapeutic parameters can significantly influence the outcome.
Evaluation of the leap motion controller as a new contact-free pointing device.
Bachmann, Daniel; Weichert, Frank; Rinkenauer, Gerhard
2014-12-24
This paper presents a Fitts' law-based analysis of the user's performance in selection tasks with the Leap Motion Controller compared with a standard mouse device. The Leap Motion Controller (LMC) is a new contact-free input system for gesture-based human-computer interaction with declared sub-millimeter accuracy. Up to this point, there has hardly been any systematic evaluation of this new system available. With an error rate of 7.8% for the LMC and 2.8% for the mouse device, movement times twice as large as for a mouse device and high overall effort ratings, the Leap Motion Controller's performance as an input device for everyday generic computer pointing tasks is rather limited, at least with regard to the selection recognition provided by the LMC.
Evaluation of the Leap Motion Controller as a New Contact-Free Pointing Device
Bachmann, Daniel; Weichert, Frank; Rinkenauer, Gerhard
2015-01-01
This paper presents a Fitts' law-based analysis of the user's performance in selection tasks with the Leap Motion Controller compared with a standard mouse device. The Leap Motion Controller (LMC) is a new contact-free input system for gesture-based human-computer interaction with declared sub-millimeter accuracy. Up to this point, there has hardly been any systematic evaluation of this new system available. With an error rate of 7.8 % for the LMC and 2.8% for the mouse device, movement times twice as large as for a mouse device and high overall effort ratings, the Leap Motion Controller's performance as an input device for everyday generic computer pointing tasks is rather limited, at least with regard to the selection recognition provided by the LMC. PMID:25609043
Brimelow, Rachel E; Gibney, Annie; Meakin, Suzanne; Wollin, Judy A
2017-04-01
Continued development of mobile technology now allows access to information at the point-of-care. This study was conducted to evaluate the use of one such tool on a mobile device, from the carer perspective. Caregivers across 12 aged-care facilities were supplied mobile devices to access a Picture Care Plan (PCP), a specific tool designed around the role of the personal carer. An anonymous questionnaire was subsequently completed by 85 carers with questions relating to participants' experience. Perceived helpfulness of the PCP at the point-of-care was high (87%). A significant number of participants believed the use of the PCP increased resident safety and quality of care (76%). Practical components related to the carrying of the device, network speed and the requirement to maintain communication with senior members of staff to ascertain updates were also expressed by participants. Findings suggest that staff are receptive to adoption of mobile devices to access care directives at the point-of-care and that the technology is useful.
Characterizing Quality Factor of Niobium Resonators Using a Markov Chain Monte Carlo Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basu Thakur, Ritoban; Tang, Qing Yang; McGeehan, Ryan
The next generation of radiation detectors in high precision Cosmology, Astronomy, and particle-astrophysics experiments will rely heavily on superconducting microwave resonators and kinetic inductance devices. Understanding the physics of energy loss in these devices, in particular at low temperatures and powers, is vital. We present a comprehensive analysis framework, using Markov Chain Monte Carlo methods, to characterize loss due to two-level system in concert with quasi-particle dynamics in thin-film Nb resonators in the GHz range.
Microwave-triggered laser switch
Piltch, M.S.
1982-05-19
A high-repetition rate switch is described for delivering short duration, high-powered electrical pulses from a pulsed-charged dc power supply. The present invention utilizes a microwave-generating device such as a magnetron that is capable of producing high-power pulses at high-pulse repetition rates and fast-pulse risetimes for long periods with high reliability. The rail-gap electrodes provide a large surface area that reduces induction effects and minimizes electrode erosion. Additionally, breakdown is initiated in a continuous geometric fashion that also increases operating lifetime of the device.
Microwave-triggered laser switch
Piltch, Martin S.
1984-01-01
A high-repetition rate switch for delivering short duration, high-power electrical pulses from a pulsed-charged dc power supply. The present invention utilizes a microwave-generating device such as a magnetron that is capable of producing high-power pulses at high-pulse repetition rates and fast-pulse risetimes for long periods with high reliability. The rail-gap electrodes provide a large surface area that reduces induction effects and minimizes electrode erosion. Additionally, breakdown is initiated in a continuous geometric fashion that also increases operating lifetime of the device.
AC induction field heating of graphite foam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klett, James W.; Rios, Orlando; Kisner, Roger
A magneto-energy apparatus includes an electromagnetic field source for generating a time-varying electromagnetic field. A graphite foam conductor is disposed within the electromagnetic field. The graphite foam when exposed to the time-varying electromagnetic field conducts an induced electric current, the electric current heating the graphite foam. An energy conversion device utilizes heat energy from the heated graphite foam to perform a heat energy consuming function. A device for heating a fluid and a method of converting energy are also disclosed.
Tofacitinib as Induction and Maintenance Therapy for Ulcerative Colitis.
Sandborn, William J; Su, Chinyu; Sands, Bruce E; D'Haens, Geert R; Vermeire, Séverine; Schreiber, Stefan; Danese, Silvio; Feagan, Brian G; Reinisch, Walter; Niezychowski, Wojciech; Friedman, Gary; Lawendy, Nervin; Yu, Dahong; Woodworth, Deborah; Mukherjee, Arnab; Zhang, Haiying; Healey, Paul; Panés, Julian
2017-05-04
Tofacitinib, an oral, small-molecule Janus kinase inhibitor, was shown to have potential efficacy as induction therapy for ulcerative colitis in a phase 2 trial. We further evaluated the efficacy of tofacitinib as induction and maintenance therapy. We conducted three phase 3, randomized, double-blind, placebo-controlled trials of tofacitinib therapy in adults with ulcerative colitis. In the OCTAVE Induction 1 and 2 trials, 598 and 541 patients, respectively, who had moderately to severely active ulcerative colitis despite previous conventional therapy or therapy with a tumor necrosis factor antagonist were randomly assigned to receive induction therapy with tofacitinib (10 mg twice daily) or placebo for 8 weeks. The primary end point was remission at 8 weeks. In the OCTAVE Sustain trial, 593 patients who had a clinical response to induction therapy were randomly assigned to receive maintenance therapy with tofacitinib (either 5 mg or 10 mg twice daily) or placebo for 52 weeks. The primary end point was remission at 52 weeks. In the OCTAVE Induction 1 trial, remission at 8 weeks occurred in 18.5% of the patients in the tofacitinib group versus 8.2% in the placebo group (P=0.007); in the OCTAVE Induction 2 trial, remission occurred in 16.6% versus 3.6% (P<0.001). In the OCTAVE Sustain trial, remission at 52 weeks occurred in 34.3% of the patients in the 5-mg tofacitinib group and 40.6% in the 10-mg tofacitinib group versus 11.1% in the placebo group (P<0.001 for both comparisons with placebo). In the OCTAVE Induction 1 and 2 trials, the rates of overall infection and serious infection were higher with tofacitinib than with placebo. In the OCTAVE Sustain trial, the rate of serious infection was similar across the three treatment groups, and the rates of overall infection and herpes zoster infection were higher with tofacitinib than with placebo. Across all three trials, adjudicated nonmelanoma skin cancer occurred in five patients who received tofacitinib and in one who received placebo, and adjudicated cardiovascular events occurred in five who received tofacitinib and in none who received placebo; as compared with placebo, tofacitinib was associated with increased lipid levels. In patients with moderately to severely active ulcerative colitis, tofacitinib was more effective as induction and maintenance therapy than placebo. (Funded by Pfizer; OCTAVE Induction 1, OCTAVE Induction 2, and OCTAVE Sustain ClinicalTrials.gov numbers, NCT01465763 , NCT01458951 , and NCT01458574 , respectively.).
Low inductance power electronics assembly
Herron, Nicholas Hayden; Mann, Brooks S.; Korich, Mark D.; Chou, Cindy; Tang, David; Carlson, Douglas S.; Barry, Alan L.
2012-10-02
A power electronics assembly is provided. A first support member includes a first plurality of conductors. A first plurality of power switching devices are coupled to the first support member. A first capacitor is coupled to the first support member. A second support member includes a second plurality of conductors. A second plurality of power switching devices are coupled to the second support member. A second capacitor is coupled to the second support member. The first and second pluralities of conductors, the first and second pluralities of power switching devices, and the first and second capacitors are electrically connected such that the first plurality of power switching devices is connected in parallel with the first capacitor and the second capacitor and the second plurality of power switching devices is connected in parallel with the second capacitor and the first capacitor.
Body motion for powering biomedical devices.
Romero, Edwar; Warrington, Robert O; Neuman, Michael R
2009-01-01
Kinetic energy harvesting has been demonstrated as a useful technique for powering portable electronic devices. Body motion can be used to generate energy to power small electronic devices for biomedical applications. These scavengers can recharge batteries, extending their operation lifetime or even replace them. This paper addresses the generation of energy from human activities. An axial flux generator is presented using body motion for powering miniature biomedical devices. This generator presents a gear-shaped planar coil and a multipole NdFeB permanent magnet (PM) ring with an attached eccentric weight. The device generates energy by electromagnetic induction on the planar coil when subject to a changing magnetic flux due to the generator oscillations produced by body motion. A 1.5 cm(3) prototype has generated 3.9 microW of power while walking with the generator placed laterally on the ankle.
NASA Astrophysics Data System (ADS)
Marshall, Kenneth L.; Adlesberger, Kathleen; Kolodzie, Benjamin; Myhre, Graham; Griffin, DeVon W.
2005-08-01
By design, point-diffraction interferometers are much less sensitive to environmental disturbances than dual-path interferometers, but, until very recently, have not been capable of phase shifting. The liquid crystal point-diffraction interferometer (LCPDI) utilizes a dye-doped, liquid crystal (LC) electro-optical device that functions as both the point-diffraction source and the phase-shifting element, yielding a phase-shifting diagnostic device that is significantly more compact and robust while using fewer optical elements than conventional dual-path interferometers. These attributes make the LCPDI of special interest for diagnostic applications in the scientific, commercial, military, and industrial sectors, where vibration insensitivity, power requirements, size, weight, and cost are critical issues. Until very recently, LCPDI devices have used a plastic microsphere embedded in the LC fluid layer as the point-diffraction source. The process for fabricating microsphere-based LCPDI devices is low-yield, labor-intensive, and very "hands-on" great care and skill are required to produce devices with adequate interference fringe contrast for diagnostic measurements. With the goal of evolving the LCPDI beyond the level of a laboratory prototype in mind, we have developed "second-generation" LCPDI devices in which the reference-diffracting elements are an integral part of the substrates by depositing a suitable optical material (vapor-deposited thin films or photoresist) directly onto the substrate surface. These "structured" substrates eliminate many of the assembly difficulties and performance limitations of current LCPDI devices as well as open the possibility of mass-producing LCPDI devices at low cost by the same processes used to manufacture commercial LC displays.
Power Quality Improvement in Induction Furnace by Harmonic Reduction Using Dynamic Voltage Restorer
NASA Astrophysics Data System (ADS)
Saggu, Tejinder Singh; Singh, Lakhwinder
2016-06-01
Induction furnaces are used in wide quantity under different capacities for annual production of around 25 million tons of iron and steel in India. It plays a vital role in various manufacturing processes around the world for melting different types of metal scraps i. e. Copper, Cast Iron, Aluminium, Steel, Brass, Bronze, Silicon, Gold, Silver etc. which are further used in many other industrial applications. The induction furnace causes a huge disturbance to the utility and nearby consumers during its operation due to its non-linear characteristics. This is a serious phenomenon responsible for power quality degradation in the power system. This paper presents methodology to improve the power quality degradation caused by induction furnace using Dynamic Voltage Restorer (DVR) which is a type of custom power device. The real time data has been taken from an industry employing induction furnace for production of ingots from scrap material. The experimental readings are measured using power quality analyser equipment. The simulation of whole plant is done by analysing this same data and the simulation results are compared with actual onsite results. Then, solution methodology using DVR is presented which revealed that the implementation of DVR is an effective solution for voltage sag mitigation and harmonics improvement in induction furnace.
Nano-based sensor for assessment of weaponry structural degradation
NASA Astrophysics Data System (ADS)
Brantley, Christina L.; Edwards, Eugene; Ruffin, Paul B.; Kranz, Michael
2016-04-01
Missiles and weaponry-based systems are composed of metal structures that can degrade after prolonged exposure to environmental elements. A particular concern is accumulation of corrosion that generally results from prolonged environmental exposure. Corrosion, defined as the unintended destruction or deterioration of a material due to its interaction with the environment, can negatively affect both equipment and infrastructure. System readiness and safety can be reduced if corrosion is not detected, prevented and managed. The current corrosion recognition methods (Visual, Radiography, Ultrasonics, Eddy Current, and Thermography) are expensive and potentially unreliable. Visual perception is the most commonly used method for determining corrosion in metal. Utilization of an inductance-based sensor system is being proposed as part of the authors' research. Results from this research will provide a more efficient, economical, and non-destructive sensing approach. Preliminary results demonstrate a highly linear degradation within a corrosive environment due to the increased surface area available on the sensor coupon. The inductance of the devices, which represents a volume property of the coupon, demonstrated sensitivity to corrosion levels. The proposed approach allows a direct mass-loss measurement based on the change in the inductance of the coupon when placed in an alternating magnetic field. Prototype devices have demonstrated highly predictable corrosion rates that are easily measured using low-power small electronic circuits and energy harvesting methods to interrogate the sensor. Preliminary testing demonstrates that the device concept is acceptable and future opportunities for use in low power embedded applications are achievable. Key results in this paper include the assessment of typical Army corrosion cost, degradation patterns of varying metal materials, and application of wireless sensors elements.
ERIC Educational Resources Information Center
Wida, Sam
1992-01-01
Uses extremely strong neodymium magnets to demonstrate several principles of physics including electromagnetic induction, Lenz's Law, domain theory, demagnetization, the Curie point, and magnetic flux lines. (MDH)
Gschwind, Michael K
2013-04-16
Mechanisms for generating and executing programs for a floating point (FP) only single instruction multiple data (SIMD) instruction set architecture (ISA) are provided. A computer program product comprising a computer recordable medium having a computer readable program recorded thereon is provided. The computer readable program, when executed on a computing device, causes the computing device to receive one or more instructions and execute the one or more instructions using logic in an execution unit of the computing device. The logic implements a floating point (FP) only single instruction multiple data (SIMD) instruction set architecture (ISA), based on data stored in a vector register file of the computing device. The vector register file is configured to store both scalar and floating point values as vectors having a plurality of vector elements.
40 CFR 141.100 - Criteria and procedures for public water systems using point-of-entry devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Criteria and procedures for public water systems using point-of-entry devices. 141.100 Section 141.100 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Use of Non-Centralized Treatment Devices §...
Pöttgen, Christoph; Gauler, Thomas; Bellendorf, Alexander; Guberina, Maja; Bockisch, Andreas; Schwenzer, Nina; Heinzelmann, Frank; Cordes, Sebastian; Schuler, Martin H; Welter, Stefan; Stamatis, Georgios; Friedel, Godehard; Darwiche, Kaid; Jöckel, Karl-Heinz; Eberhardt, Wilfried; Stuschke, Martin
2016-07-20
A confirmatory analysis was performed to determine the prognostic value of metabolic response during induction chemotherapy followed by bimodality/trimodality treatment of patients with operable locally advanced non-small-cell lung cancer. Patients with potentially operable stage IIIA(N2) or selected stage IIIB non-small-cell lung cancer received three cycles of cisplatin/paclitaxel (induction chemotherapy) followed by neoadjuvant radiochemotherapy (RCT) to 45 Gy (1.5 Gy twice per day concurrent cisplatin/vinorelbine) within the ESPATUE (Phase III Study of Surgery Versus Definitive Concurrent Chemoradiotherapy Boost in Patients With Resectable Stage IIIA[N2] and Selected IIIB Non-Small-Cell Lung Cancer After Induction Chemotherapy and Concurrent Chemoradiotherapy) trial. Positron emission tomography scans were recommended before (t0) and after (t2) induction chemotherapy. Patients who were eligible for surgery after neoadjuvant RCT were randomly assigned to definitive RCT or surgery. The prognostic value of percentage of maximum standardized uptake value (%SUVmax) remaining in the primary tumor after induction chemotherapy-%SUVremaining = SUVmax(t2)/SUVmax(t0)-was assessed by proportional hazard analysis and receiver operating characteristic analysis. Overall, 161 patients were randomly assigned (155 from the Essen and Tübingen centers), and 124 of these received positron emission tomography scans at t0 and t2. %SUVremaining as a continuous variable was prognostic for the three end points of overall survival, progression-free survival, and freedom from extracerebral progression in univariable and multivariable analysis (P < .016). The respective hazard ratios per 50% increase in %SUVremaining from multivariable analysis were 2.3 (95% CI, 1.5 to 3.4; P < .001), 1.8 (95% CI, 1.3 to 2.5; P < .001), and 1.8 (95% CI, 1.2 to 2.7; P = .006) for the three end points. %SUVremaining dichotomized at a cut point of maximum sum of sensitivity and specificity from receiver operating characteristic analysis at 36 months was also prognostic. Exploratory analysis revealed that %SUVremaining was likewise prognostic for overall survival in both treatment arms and was more closely associated with extracerebral distant metastases (P = .016) than with isolated locoregional relapses (P = .97). %SUVremaining is a predictor for survival and other end points after multimodality treatment and can serve as a parameter for treatment stratification after induction chemotherapy or for evaluation of adjuvant new systemic treatment options for high-risk patients. © 2016 by American Society of Clinical Oncology.
Unexpected Nonlinear Effects in Superconducting Transition-Edge Sensors
NASA Technical Reports Server (NTRS)
Sadleir, John
2016-01-01
When a normal metal transitions into the superconducting state the DC resistance drops from a finite value to zero over some finite transition width in temperature, current, and magnetic field. Superconducting transition-edge sensors (TESs) operate within this transition region and uses resistive changes to measure deposited thermal energy. This resistive transition is not perfectly smooth and a wide range of TES designs and materials show sub-structure in the resistive transition (as seen in smooth nonmonotonic behavior, jump discontinuities, and hysteresis in the devices current-voltage relation and derivatives of the resistance with respect to temperature, bias current, and magnetic field). TES technology has advanced to the point where for many applications this structure is the limiting factor in performance and optimization consists of finding operating points away from these structures. For example, operating at or near this structure can lead to nonlinearity in the detectors response and gain scale, limit the spectral range of the detector by limiting the usable resistive range, and degrade energy resolution. The origin of much of this substructure is unknown. This presentation investigates a number of possible sources in turn. First we model the TES as a superconducting weak-link and solve for the characteristic differential equations current and voltage time dependence. We find:(1) measured DC biased current-voltage relationship is the time-average of a much higher frequency limit cycle solution.(2) We calculate the fundamental frequency and estimate the power radiated from the TES treating the bias leads as an antennae.(3) The solution for a set of circuit parameters becomes multivalued leading to current transitions between levels.(4)The circuit parameters can change the measure resistance and mask the true critical current. As a consequence the TES resistance surface is not just a function of temperature, current, and magnetic field but is also a function of the circuit elements (such as shunt resistor, SQUID inductance, and capacitor values). In other words, same device measured in different electrical circuits will have a different resistive surface in temperature, current, and magnetic field. Next we consider that at the transition temperature of a superconductor both the magnetic penetration depth and coherence length are divergent. As a consequence these important characteristic length scales are changing with operating point. We present measurements on devices showing commensurate behavior between these characteristic lengths and the length scale of added normal metal structures. Reordering of proximity vortices leads to discontinuities and irreversibility of the current-voltage curves. Last we consider a weak-link TES including both thermal activated resistance effects and the effect of the magnetic penetration depth being a function of temperature and magnetic field. We derive its impact on the resistive transition surface and the important device parameters a and b.
47 CFR 73.57 - Remote reading antenna and common point ammeters.
Code of Federal Regulations, 2010 CFR
2010-10-01
... remote leads to the indicating instruments. (2) Inductive coupling to radio frequency current sensing... 47 Telecommunication 4 2010-10-01 2010-10-01 false Remote reading antenna and common point... RADIO SERVICES RADIO BROADCAST SERVICES AM Broadcast Stations § 73.57 Remote reading antenna and common...
Kos, Bor; Valič, Blaž; Kotnik, Tadej; Gajšek, Peter
2012-10-07
Induction heating equipment is a source of strong and nonhomogeneous magnetic fields, which can exceed occupational reference levels. We investigated a case of an induction tempering tunnel furnace. Measurements of the emitted magnetic flux density (B) were performed during its operation and used to validate a numerical model of the furnace. This model was used to compute the values of B and the induced in situ electric field (E) for 15 different body positions relative to the source. For each body position, the computed B values were used to determine their maximum and average values, using six spatial averaging schemes (9-285 averaging points) and two averaging algorithms (arithmetic mean and quadratic mean). Maximum and average B values were compared to the ICNIRP reference level, and E values to the ICNIRP basic restriction. Our results show that in nonhomogeneous fields, the maximum B is an overly conservative predictor of overexposure, as it yields many false positives. The average B yielded fewer false positives, but as the number of averaging points increased, false negatives emerged. The most reliable averaging schemes were obtained for averaging over the torso with quadratic averaging, with no false negatives even for the maximum number of averaging points investigated.
Pruna, Raquel; Palacio, Francisco; Baraket, Abdoullatif; Zine, Nadia; Streklas, Angelos; Bausells, Joan; Errachid, Abdelhamid; López, Manel
2018-02-15
Miniaturizing potentiostats, keeping their cost low and yet preserving full measurement characteristics (e.g. bandwidth, determination of capacitive/inductive contribution to sensor's impedance and parallel screening) is still an unresolved challenge in bioelectronics. In this work, the combination of simple analogue circuitry together with powerful microcontrollers and a digital filter implementation is presented as an alternative to complex and incomplete architectures reported in the literature. A low-cost acquisition electronic system fully integrated with a biosensors platform containing eight gold working microelectrodes and integrated reference and counter electrodes was developed and validated. The manufacturing cost of the prototype was kept below 300 USD. The performance of the proposed device was benchmarked against a commercial impedance analyzer through the electrochemical analysis of a highly sensitive biosensor for the detection of tumor necrosis factor α (TNF-α) within the randomly chosen range of 266pg/mL to 666ng/mL in physiological medium (PBS). A strong correlation between the outputs of both devices was found in a critical range of frequencies (1-10Hz), and several TNF-α cytokine concentrations were properly discriminated. These results are very promising for the development of low-cost, portable and miniaturized electrochemical systems for point-of-care and environmental diagnosis. Copyright © 2017 Elsevier B.V. All rights reserved.
Fernández-Martos, Carlos; Pericay, Carles; Aparicio, Jorge; Salud, Antonieta; Safont, Mariajose; Massuti, Bertomeu; Vera, Ruth; Escudero, Pilar; Maurel, Joan; Marcuello, Eugenio; Mengual, Jose Luis; Saigi, Eugenio; Estevan, Rafael; Mira, Moises; Polo, Sonia; Hernandez, Ana; Gallen, Manuel; Arias, Fernando; Serra, Javier; Alonso, Vicente
2010-02-10
PURPOSE The optimal therapeutic sequence of the adjuvant chemotherapy component of preoperative chemoradiotherapy (CRT) for patients with locally advanced rectal cancer is controversial. Induction chemotherapy before preoperative CRT may be associated with better efficacy and compliance. PATIENTS AND METHODS A total of 108 patients with locally advanced rectal cancer were randomly assigned to arm A-preoperative CRT with capecitabine, oxaliplatin, and concurrent radiation followed by surgery and four cycles of postoperative adjuvant capecitabine and oxaliplatin (CAPOX)-or arm B-induction CAPOX followed by CRT and surgery. The primary end point was pathologic complete response rate (pCR). Results On an intention-to-treat basis, the pCR for arms A and B were 13.5% (95% CI, 5.6% to 25.8%) and 14.3% (95% CI, 6.4% to 26.2%), respectively. There were no statistically significant differences in other end points, including downstaging, tumor regression, and R0 resection. Overall, chemotherapy treatment exposure was higher in arm B than in arm A for both oxaliplatin (P < .0001) and capecitabine (P < .0001). During CRT, grades 3 to 4 adverse events were similar in both arms but were significantly higher in arm A during postoperative adjuvant CT than with induction CT in arm B. There were three deaths in each arm during the treatment period. CONCLUSION Compared with postoperative adjuvant CAPOX, induction CAPOX before CRT had similar pCR and complete resection rates. It did achieve more favorable compliance and toxicity profiles. On the basis of these findings, a phase III study to definitively test the induction strategy is warranted.
Transistor screening evaluation SJ6708H
NASA Technical Reports Server (NTRS)
Barton, J. L.
1978-01-01
A manufacturer was contracted to screen 125 transistors capable of withstanding the high level inductive voltages obtained when switching inductive loads. Planned differences included a change in die bonding to comply with NASA's desire for hard solder die attachment which further necessitated a change in package to conform to the required die mounting system. Evaluation of the electrical performance and recommended changes were made during the preliminary build phase of the program. The following sections are outlined: (1) narrative outline; (2) customer data summary and X-ray reports; (3) device specification; (4) failure analysis reports; (5) test facilities list; and (6) test measurement data.
Engineering of a novel Ca{sup 2+}-regulated kinesin molecular motor using a calmodulin dimer linker
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shishido, Hideki; Maruta, Shinsaku, E-mail: maruta@soka.ac.jp
Highlights: Black-Right-Pointing-Pointer Engineered kinesin-M13 and calmodulin involving single cysteine were prepared. Black-Right-Pointing-Pointer CaM mutant was cross-linked to dimer by bifunctional thiol reactive reagent. Black-Right-Pointing-Pointer Kinesin-M13 was dimerized via CaM dimer in the presence of calcium. Black-Right-Pointing-Pointer Function of the engineered kinesin was regulated by a Ca{sup 2+}-calmodulin dimer linker. -- Abstract: The kinesin-microtubule system holds great promise as a molecular shuttle device within biochips. However, one current barrier is that such shuttles do not have 'on-off' control of their movement. Here we report the development of a novel molecular motor powered by an accelerator and brake system, using a kinesinmore » monomer and a calmodulin (CaM) dimer. The kinesin monomer, K355, was fused with a CaM target peptide (M13 peptide) at the C-terminal part of the neck region (K355-M13). We also prepared CaM dimers using CaM mutants (Q3C), (R86C), or (A147C) and crosslinkers that react with cysteine residues. Following induction of K355-M13 dimerization with CaM dimers, we measured K355-M13 motility and found that it can be reversibly regulated in a Ca{sup 2+}-dependent manner. We also found that velocities of K355-M13 varied depending on the type and crosslink position of the CaM dimer used; crosslink length also had a moderate effect on motility. These results suggest Ca{sup 2+}-dependent dimerization of K355-M13 could be used as a novel molecular shuttle, equipped with an accelerator and brake system, for biochip applications.« less
2013-01-01
Comparison of resistive switching memory characteristics using copper (Cu) and aluminum (Al) electrodes on GeOx/W cross-points has been reported under low current compliances (CCs) of 1 nA to 50 μA. The cross-point memory devices are observed by high-resolution transmission electron microscopy (HRTEM). Improved memory characteristics are observed for the Cu/GeOx/W structures as compared to the Al/GeOx/W cross-points owing to AlOx formation at the Al/GeOx interface. The RESET current increases with the increase of the CCs varying from 1 nA to 50 μA for the Cu electrode devices, while the RESET current is high (>1 mA) and independent of CCs varying from 1 nA to 500 μA for the Al electrode devices. An extra formation voltage is needed for the Al/GeOx/W devices, while a low operation voltage of ±2 V is needed for the Cu/GeOx/W cross-point devices. Repeatable bipolar resistive switching characteristics of the Cu/GeOx/W cross-point memory devices are observed with CC varying from 1 nA to 50 μA, and unipolar resistive switching is observed with CC >100 μA. High resistance ratios of 102 to 104 for the bipolar mode (CCs of 1 nA to 50 μA) and approximately 108 for the unipolar mode are obtained for the Cu/GeOx/W cross-points. In addition, repeatable switching cycles and data retention of 103 s are observed under a low current of 1 nA for future low-power, high-density, nonvolatile, nanoscale memory applications. PMID:24305116
Garcia-Garcia, Hector M; McFadden, Eugène P; Farb, Andrew; Mehran, Roxana; Stone, Gregg W; Spertus, John; Onuma, Yoshinobu; Morel, Marie-Angèle; van Es, Gerrit-Anne; Zuckerman, Bram; Fearon, William F; Taggart, David; Kappetein, Arie-Pieter; Krucoff, Mitchell W; Vranckx, Pascal; Windecker, Stephan; Cutlip, Donald; Serruys, Patrick W
2018-06-14
The Academic Research Consortium (ARC)-2 initiative revisited the clinical and angiographic end point definitions in coronary device trials, proposed in 2007, to make them more suitable for use in clinical trials that include increasingly complex lesion and patient populations and incorporate novel devices such as bioresorbable vascular scaffolds. In addition, recommendations for the incorporation of patient-related outcomes in clinical trials are proposed. Academic Research Consortium-2 is a collaborative effort between academic research organizations in the United States and Europe, device manufacturers, and European, US, and Asian regulatory bodies. Several in-person meetings were held to discuss the changes that have occurred in the device landscape and in clinical trials and regulatory pathways in the last decade. The consensus-based end point definitions in this document are endorsed by the stakeholders of this document and strongly advocated for clinical trial purposes. This Academic Research Consortium-2 document provides further standardization of end point definitions for coronary device trials, incorporating advances in technology and knowledge. Their use will aid interpretation of trial outcomes and comparison among studies, thus facilitating the evaluation of the safety and effectiveness of these devices.
Streamlined approach to mapping the magnetic induction of skyrmionic materials.
Chess, Jordan J; Montoya, Sergio A; Harvey, Tyler R; Ophus, Colin; Couture, Simon; Lomakin, Vitaliy; Fullerton, Eric E; McMorran, Benjamin J
2017-06-01
Recently, Lorentz transmission electron microscopy (LTEM) has helped researchers advance the emerging field of magnetic skyrmions. These magnetic quasi-particles, composed of topologically non-trivial magnetization textures, have a large potential for application as information carriers in low-power memory and logic devices. LTEM is one of a very few techniques for direct, real-space imaging of magnetic features at the nanoscale. For Fresnel-contrast LTEM, the transport of intensity equation (TIE) is the tool of choice for quantitative reconstruction of the local magnetic induction through the sample thickness. Typically, this analysis requires collection of at least three images. Here, we show that for uniform, thin, magnetic films, which includes many skyrmionic samples, the magnetic induction can be quantitatively determined from a single defocused image using a simplified TIE approach. Copyright © 2017 Elsevier B.V. All rights reserved.
Tunable sub-gap radiation detection with superconducting resonators
NASA Astrophysics Data System (ADS)
Dupré, O.; Benoît, A.; Calvo, M.; Catalano, A.; Goupy, J.; Hoarau, C.; Klein, T.; Le Calvez, K.; Sacépé, B.; Monfardini, A.; Levy-Bertrand, F.
2017-04-01
We have fabricated planar amorphous indium oxide superconducting resonators ({T}{{c}}˜ 2.8 K) that are sensitive to frequency-selective radiation in the range of 7-10 GHz. Those values lay far below twice the superconducting gap that is worth about 200 GHz. The photon detection consists in a shift of the fundamental resonance frequency. We show that the detected frequency can be adjusted by modulating the total length of the superconducting resonator. We attribute those observations to the excitation of higher-order resonance modes. The coupling between the fundamental lumped and the higher order distributed resonance is due to the kinetic inductance nonlinearity with current. These devices, that we have called sub-gap kinetic inductance detectors, are to be distinguished from the standard kinetic inductance detectors in which quasi-particles are generated when incident light breaks down Cooper pairs.
Prior schemata transfer as an account for assessing the intuitive use of new technology.
Fischer, Sandrine; Itoh, Makoto; Inagaki, Toshiyuki
2015-01-01
New devices are considered intuitive when they allow users to transfer prior knowledge. Drawing upon fundamental psychology experiments that distinguish prior knowledge transfer from new schema induction, a procedure was specified for assessing intuitive use. This procedure was tested with 31 participants who, prior to using an on-board computer prototype, studied its screenshots in reading vs. schema induction conditions. Distinct patterns of transfer or induction resulted for features of the prototype whose functions were familiar or unfamiliar, respectively. Though moderated by participants' cognitive style, these findings demonstrated a means for quantitatively assessing transfer of prior knowledge as the operation that underlies intuitive use. Implications for interface evaluation and design, as well as potential improvements to the procedure, are discussed. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Inductance analyzer based on auto-balanced circuit for precision measurement of fluxgate impedance
NASA Astrophysics Data System (ADS)
Setiadi, Rahmondia N.; Schilling, Meinhard
2018-05-01
An instrument for fluxgate sensor impedance measurement based on an auto-balanced circuit has been designed and characterized. The circuit design is adjusted to comply with the fluxgate sensor characteristics which are low impedance and highly saturable core with very high permeability. The system utilizes a NI-DAQ card and LabVIEW to process the signal acquisition and evaluation. Some fixed reference resistances are employed for system calibration using linear regression. A multimeter HP 34401A and impedance analyzer Agilent 4294A are used as calibrator and validator for the resistance and inductance measurements. Here, we realized a fluxgate analyzer instrument based on auto-balanced circuit, which measures the resistance and inductance of the device under test with a small error and much lower excitation current to avoid core saturation compared to the used calibrator.
Saver, J L; Jahan, R; Levy, E I; Jovin, T G; Baxter, B; Nogueira, R; Clark, W; Budzik, R; Zaidat, O O
2014-07-01
Self-expanding stent retrievers are a promising new device class designed for rapid flow restoration in acute cerebral ischaemia. The SOLITAIRE™ Flow Restoration device (SOLITAIRE) has shown high rates of recanalization in preclinical models and in uncontrolled clinical series. (1) To demonstrate non-inferiority of SOLITAIRE compared with a legally marketed device, the MERCI Retrieval System®; (2) To demonstrate safety, feasibility, and efficacy of SOLITAIRE in subjects requiring mechanical thrombectomy diagnosed with acute ischaemic stroke. DESIGN : Multicenter, randomized, prospective, controlled trial with blinded primary end-point ascertainment. Key entry criteria include: age 22-85; National Institute of Health Stroke Scale (NIHSS) ≥8 and <30; clinical and imaging findings consistent with acute ischaemic stroke; patient ineligible or failed intravenous tissue plasminogen activator; accessible occlusion in M1 or M2 middle cerebral artery, internal carotid artery, basilar artery, or vertebral artery; and patient able to be treated within 8 h of onset. Sites first participate in a roll-in phase, treating two patients with the SOLITAIRE device, before proceeding to the randomized phase. In patients unresponsive to the initially assigned therapy, after the angiographic component of the primary end-point is ascertained (reperfusion with the initial assigned device), rescue therapy with other reperfusion techniques is permitted. The primary efficacy end-point is successful recanalization with the assigned study device (no use of rescue therapy) and with no symptomatic intracranial haemorrhage. Successful recanalization is defined as achieving Thrombolysis In Myocardial Ischemia 2 or 3 flow in all treatable vessels. The primary safety end-point is the incidence of device-related and procedure-related serious adverse events. A major secondary efficacy end-point is time to achieve initial recanalization. Additional secondary end-points include clinical outcomes at 90 days and radiologic haemorrhagic transformation. © 2012 The Authors. International Journal of Stroke © 2012 World Stroke Organization.
Gryz, Krzysztof
2013-01-01
Leakage of electromagnetic fields (EMF) from short-wave radiofrequency physiotherapeutic diathermies (SWDs) may cause health and safety hazards affecting unintentionally exposed workers (W) or general public (GP) members (assisting patient exposed during treatment or presenting there for other reasons). Increasing use of electronic active implantable medical devices (AIMDs), by patients, attendants, and workers, needs attention because dysfunctions of these devices may be caused by electromagnetic interactions. EMF emitted by 12 SWDs (with capacitive or inductive applicators) were assessed following international guidelines on protection against EMF exposure (International Commission on Nonionizing Radiation Protection for GP and W, new European directive 2013/35/EU for W, European Recommendation for GP, and European Standard EN 50527-1 for AIMD users). Direct EMF hazards for humans near inductive applicators were identified at a distance not exceeding 45 cm for W or 62 cm for GP, but for AIMD users up to 90 cm (twice longer than that for W and 50% longer than that for GP because EMF is pulsed modulated). Near capacitive applicators emitting continuous wave, the corresponding distances were: 120 cm for W or 150 cm for both—GP or AIMD users. This assessment does not cover patients who undergo SWD treatment (but it is usually recommended for AIMD users to be careful with EMF treatment). PMID:24089662
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferguson, Jill Wisnewski
2006-01-01
The inductively coupled plasma (ICP) is an atmospheric pressure ionization source. Traditionally, the plasma is sampled via a sampler cone. A supersonic jet develops behind the sampler, and this region is pumped down to a pressure of approximately one Torr. A skimmer cone is located inside this zone of silence to transmit ions into the mass spectrometer. The position of the sampler and skimmer cones relative to the initial radiation and normal analytical zones of the plasma is key to optimizing the useful analytical signal [1]. The ICP both atomizes and ionizes the sample. Polyatomic ions form through ion-molecule interactionsmore » either in the ICP or during ion extraction [l]. Common polyatomic ions that inhibit analysis include metal oxides (MO +), adducts with argon, the gas most commonly used to make up the plasma, and hydride species. While high resolution devices can separate many analytes from common interferences, this is done at great cost in ion transmission efficiency--a loss of 99% when using high versus low resolution on the same instrument [2]. Simple quadrupole devices, which make up the bulk of ICP-MS instruments in existence, do not present this option. Therefore, if the source of polyatomic interferences can be determined and then manipulated, this could potentially improve the figures of merit on all ICP-MS devices, not just the high resolution devices often utilized to study polyatomic interferences.« less
Endocardial Energy Harvesting by Electromagnetic Induction.
Zurbuchen, Adrian; Haeberlin, Andreas; Bereuter, Lukas; Pfenniger, Alois; Bosshard, Simon; Kernen, Micha; Philipp Heinisch, Paul; Fuhrer, Juerg; Vogel, Rolf
2018-02-01
cardiac pacemakers require regular medical follow-ups to ensure proper functioning. However, device replacements due to battery depletion are common and account for ∼25% of all implantation procedures. Furthermore, conventional pacemakers require pacemaker leads which are prone to fractures, dislocations or isolation defects. The ensuing surgical interventions increase risks for the patients and costs that need to be avoided. in this study, we present a method to harvest energy from endocardial heart motions. We developed a novel generator, which converts the heart's mechanical into electrical energy by electromagnetic induction. A mathematical model has been introduced to identify design parameters strongly related to the energy conversion efficiency of heart motions and fit the geometrical constraints for a miniaturized transcatheter deployable device. The implemented final design was tested on the bench and in vivo. the mathematical model proved an accurate method to estimate the harvested energy. For three previously recorded heart motions, the model predicted a mean output power of 14.5, 41.9, and 16.9 μW. During an animal experiment, the implanted device harvested a mean output power of 0.78 and 1.7 μW at a heart rate of 84 and 160 bpm, respectively. harvesting kinetic energy from endocardial motions seems feasible. Implanted at an energetically favorable location, such systems might become a welcome alternative to extend the lifetime of cardiac implantable electronic device. the presented endocardial energy harvesting concept has the potential to turn pacemakers into battery- and leadless systems and thereby eliminate two major drawbacks of contemporary systems.
Maxillary-driven simultaneous maxillo-mandibular distraction for hemifacial microsomia.
Nakajima, Hideo; Sakamoto, Yoshiaki; Tamada, Ikkei; Ogata, Hisao; Kishi, Kazuo; Sakamoto, Teruo
2011-12-01
We treat hemifacial microsomia with a combination of surgery and orthodontic treatment during the growth period, resulting in early improvement in facial asymmetry and the induction of normal growth. We previously used gradual distraction of the mandibular ramus for Pruzansky's type II classification (Pruzansky, 1969). In type II cases, the maxilla should also be treated actively as, using this technique, improvement of the occlusal plane is difficult to achieve, resulting in a cross bite and difficulties in post-operative orthodontic treatment-especially in older patients. Morphologically, the mandibular angle region of the operative side is flat, and the angle of the mouth remains elevated. We performed mandibular-driven simultaneous maxillo-mandibular distraction while the occlusion was maintained using intermaxillary anchorage. However, mandibular-driven distraction tended to elongate the face because the mandible only elongated downwards and the mandibular ramus did not reach the glenoid. Furthermore, external distraction devices produce significant distress for patients until removal of the device and cause scars on the face. We developed a new internal distraction device with a variable angle and performed maxillary-driven simultaneous maxillo-mandibular distraction using this device. The result was morphologically satisfactory and solved the above problems. Because the patient was in the growth period, careful follow-up and induction to normal growth were important while the inferior growth of the affected side was monitored. Copyright © 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Jurns, John M.; McQuillen, John B.; Gaby, Joseph D., Jr.; Sinacore, Steven A., Jr.
2009-01-01
Liquid acquisition devices (LADs) can be utilized within a propellant tank in space to deliver single-phase liquid to the engine in low gravity. One type of liquid acquisition device is a screened gallery whereby a fine mesh screen acts as a 'bubble filter' and prevents the gas bubbles from passing through until a crucial pressure differential condition across the screen, called the bubble point, is reached. This paper presents data for LAD bubble point data in liquid methane (LCH4) for stainless steel Dutch twill screens with mesh sizes of 325 by 2300. These tests represent the first known nonproprietary effort to collect bubble point data for LCH4.
Streamline-based microfluidic device
NASA Technical Reports Server (NTRS)
Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Kasdan, Harvey (Inventor)
2013-01-01
The present invention provides a streamline-based device and a method for using the device for continuous separation of particles including cells in biological fluids. The device includes a main microchannel and an array of side microchannels disposed on a substrate. The main microchannel has a plurality of stagnation points with a predetermined geometric design, for example, each of the stagnation points has a predetermined distance from the upstream edge of each of the side microchannels. The particles are separated and collected in the side microchannels.
Prehospital Emergency Inguinal Clamp Controls Hemorrhage in Cadaver Model
2013-07-01
fit at anatomic pressure points needed in hemorrhage control. The CRoC was placed on trauma manikins at the U.S. Army Med- ical Department Center and...simulant was pumped to quantify device effective- ness in testing. Points of application included proximal pressure point control of popliteal...a casualty’s wound from the point of injury on the battlefield to the emergency department has been impractical; so a device was made to replace the
Efficiency of the Lung Flute for sputum induction in patients with presumed pulmonary tuberculosis.
Sakashita, Kentaro; Fujita, Akira; Takamori, Mikio; Nagai, Takayuki; Matsumoto, Tomoshige; Saito, Takefumi; Nakagawa, Taku; Ogawa, Kenji; Shigeto, Eriko; Nakatsumi, Yasuto; Goto, Hajime; Mitarai, Satoshi
2018-04-01
High quality sputum helps increase the sensitivity of the diagnosis of pulmonary tuberculosis. To evaluate the efficiency of the acoustic device (Lung Flute; LF) in sputum induction compared with the conventional method, hypertonic saline inhalation (HSI). In this crossover study, patients with presumed pulmonary tuberculosis submitted 3 consecutive sputa: the first sputum without induction and the second and third ones using LF and HSI. We compared the efficiency of the 2 induction methods. Sixty-four participants were eligible. Thirty-five (54.6%) patients had negative smears on the first sputum without induction. Among those patients, 25.7% and 22.9% patients were smear-positive after using LF and HSI, respectively (P = .001). The positive conversion rate was not significantly different between the methods. The first samples without induction yielded 65.7% positive cultures, whereas 71.4% and 77.1% of the samples from LF and HSI were positive, respectively (P = .284). Similar results were observed in the nucleic acid amplification test [no induction (60.0%), LF (72.0%) and HSI (60.0%); P = .341]. In 29 smear-positive patients on the first sputum without induction, we observed no significant increase in smear grade, culture yield and nucleic acid amplification test positivity with either method. LF tended to induce fewer adverse events; desaturation (3.1% vs 11.1%; P = .082) and throat pain (1.5% vs 9.5%; P = .057). LF showed significantly fewer total adverse events (15.8% vs 34.9%; P = .023). Our study showed LF had similar sputum induction efficiency to HSI with relatively fewer complications. © 2017 The Authors. The Clinical Respiratory Journal Published by John Wiley & Sons Ltd.
Abductive Science Inquiry Using Mobile Devices in the Classroom
ERIC Educational Resources Information Center
Ahmed, Sohaib; Parsons, David
2013-01-01
Recent advancements in digital technology have attracted the interest of educators and researchers to develop technology-assisted inquiry-based learning environments in the domain of school science education. Traditionally, school science education has followed deductive and inductive forms of inquiry investigation, while the abductive form of…
Induction logging device with a pair of mutually perpendicular bucking coils
Koelle, Alfred R.; Landt, Jeremy A.
1981-01-01
An instrument is disclosed for mapping vertical conductive fractures in a resistive bedrock, magnetically inducing eddy currents by a pair of vertically oriented, mutually perpendicular, coplanar coils. The eddy currents drive magnetic fields which are picked up by a second, similar pair of coils.
DOT National Transportation Integrated Search
2012-12-01
The Wavetronix Matrix Radar was adapted for use at four-quadrant gate railroad crossings for the purpose of influencing exit gate behavior upon the detection of vehicles, as an alternative to buried inductive loops. Two radar devices were utilized, o...
Analysis of laser-induction hybrid cladding processing conditions
NASA Astrophysics Data System (ADS)
Huang, Yongjun; Zeng, Xiaoyan; Hu, Qianwu
2007-12-01
A new cladding approach based on laser-induction hybrid technique on flat sheets is presented in this paper. Coating is produced by means of 5kw cw CO II laser equipped with 100kw high frequent inductor, and the experiments set-up, involving a special machining-head, which can provide laser-induction hybrid heat resources simultaneously. The formation of thick NiCrSiB coating on a steel substrate by off-axial powder feeding is studied from an experimental point of view. A substrate melting energy model is developed to describe the energy relationship between laser-induction hybrid cladding and laser cladding alone quantitatively. By comparing the experimental results with the calculational ones, it is shown that the tendency of fusion zone height of theoretical calculation is in agreement with that of tests in laser-induction hybrid cladding. Via analyses and tests, the conclusions can be lead to that the fusion zone height can be increased easily and the good bond of cladding track can be achieved within wide cladding processing window in laser-induction hybrid processing. It shows that the induction heating has an obvious effect on substrate melting and metallurgical bond.
Plasma response to sustainment with imposed-dynamo current drive in HIT-SI and HIT-SI3
NASA Astrophysics Data System (ADS)
Hossack, A. C.; Jarboe, T. R.; Chandra, R. N.; Morgan, K. D.; Sutherland, D. A.; Penna, J. M.; Everson, C. J.; Nelson, B. A.
2017-07-01
The helicity injected torus—steady inductive (HIT-SI) program studies efficient, steady-state current drive for magnetic confinement plasmas using a novel experimental method. Stable, high-beta spheromaks have been sustained using steady, inductive current drive. Externally induced loop voltage and magnetic flux are oscillated together so that helicity and power injection are always positive, sustaining the edge plasma current indefinitely. Imposed-dynamo current drive (IDCD) theory further shows that the entire plasma current is sustained. The method is ideal for low aspect ratio, toroidal geometries with closed flux surfaces. Experimental studies of spheromak plasmas sustained with IDCD have shown stable magnetic profiles with evidence of pressure confinement. New measurements show coherent motion of a stable spheromak in response to the imposed perturbations. On the original device two helicity injectors were mounted on either side of the spheromak and the injected mode spectrum was predominantly n = 1. Coherent, rigid motion indicates that the spheromak is stable and a lack of plasma-generated n = 1 energy indicates that the maximum q is maintained below 1 during sustainment. Results from the HIT-SI3 device are also presented. Three inductive helicity injectors are mounted on one side of the spheromak flux conserver. Varying the relative injector phasing changes the injected mode spectrum which includes n = 2, 3, and higher modes.
Understanding and predicting the dynamics of tokamak discharges during startup and rampdown
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jackson, G. L.; Politzer, P. A.; Humphreys, D. A.
Understanding the dynamics of plasma startup and termination is important for present tokamaks and for predictive modeling of future burning plasma devices such as ITER. We report on experiments in the DIII-D tokamak that explore the plasma startup and rampdown phases and on the benchmarking of transport models. Key issues have been examined such as plasma initiation and burnthrough with limited inductive voltage and achieving flattop and maximum burn within the technical limits of coil systems and their actuators while maintaining the desired q profile. Successful rampdown requires scenarios consistent with technical limits, including controlled H-L transitions, while avoiding verticalmore » instabilities, additional Ohmic transformer flux consumption, and density limit disruptions. Discharges were typically initiated with an inductive electric field typical of ITER, 0.3 V/m, most with second harmonic electron cyclotron assist. A fast framing camera was used during breakdown and burnthrough of low Z impurity charge states to study the formation physics. An improved 'large aperture' ITER startup scenario was developed, and aperture reduction in rampdown was found to be essential to avoid instabilities. Current evolution using neoclassical conductivity in the CORSICA code agrees with rampup experiments, but the prediction of the temperature and internal inductance evolution using the Coppi-Tang model for electron energy transport is not yet accurate enough to allow extrapolation to future devices.« less
Sörenby, Anne K; Kumagai-Braesch, Makiko; Sharma, Amit; Hultenby, Kjell R; Wernerson, Annika M; Tibell, Annika B
2008-07-27
Islet graft survival inside macroencapsulation devices is suboptimal. We hypothesized that induction of neovascularization by preimplantation of devices would improve the physiological conditions, thereby lowering the number of islets required for cure. Several rat islets were transplanted to TheraCyte immunoprotective devices implanted subcutaneously in diabetic athymic mice. Cure rates in the groups with preimplanted devices were significantly better than in those with freshly implanted devices (375 islets: 8/8 vs. 1/6, P=0.003; 125 islets: 6/6 vs. 0/7, P=0.001). Morphometric evaluations of the 125 islet groups showed higher fractional and absolute volumes of endocrine tissue in the group with preimplanted devices (P<0.001 and P=0.035, respectively). In the following dose titration study, using preimplanted devices, as low as 50 islets cured diabetic mice (100% cure, n=6). We conclude that preimplantation significantly lowers the curative dose of macroencapsulated islets to levels resembling those of free islets transplanted under the renal capsule.
Power and stability limitations of resonant tunneling diodes
NASA Technical Reports Server (NTRS)
Kidner, C.; Mehdi, I.; East, J. R.; Haddad, G. I.
1990-01-01
Stability criteria for resonant tunneling diodes are investigated. Details of how extrinsic elements, such as series inductance and parallel capacitance, affect the stability are presented. A GaAs/AlAs/InGaAs/AlAs/GaAs double-barrier diode is investigated, showing the effect of different modes of low-frequency oscillation and the extrinsic circuit required for stabilization. The effect of device stabilization on high-frequency power generation is described. The main conclusions of the paper are: (1) stable resonant tunneling diode operation is difficult to obtain, and (2) the circuit and device conditions required for stable operation greatly reduce the amount of power that can be produced by these devices.
An electronic implementation of amoeba anticipation
NASA Astrophysics Data System (ADS)
Ziegler, Martin; Ochs, Karlheinz; Hansen, Mirko; Kohlstedt, Hermann
2014-02-01
In nature, the capability of memorizing environmental changes and recalling past events can be observed in unicellular organisms like amoebas. Pershin and Di Ventra have shown that such learning behavior can be mimicked in a simple memristive circuit model consisting of an LC (inductance capacitance) contour and a memristive device. Here, we implement this model experimentally by using an Ag/TiO2- x /Al memristive device. A theoretical analysis of the circuit is used to gain insight into the functionality of this model and to give advice for the circuit implementation. In this respect, the transfer function, resonant frequency, and damping behavior for a varying resistance of the memristive device are discussed in detail.
A macrochip interconnection network enabled by silicon nanophotonic devices.
Zheng, Xuezhe; Cunningham, John E; Koka, Pranay; Schwetman, Herb; Lexau, Jon; Ho, Ron; Shubin, Ivan; Krishnamoorthy, Ashok V; Yao, Jin; Mekis, Attila; Pinguet, Thierry
2010-03-01
We present an advanced wavelength-division multiplexing point-to-point network enabled by silicon nanophotonic devices. This network offers strictly non-blocking all-to-all connectivity while maximizing bisection bandwidth, making it ideal for multi-core and multi-processor interconnections. We introduce one of the key components, the nanophotonic grating coupler, and discuss, for the first time, how this device can be useful for practical implementations of the wavelength-division multiplexing network using optical proximity communications. Finite difference time-domain simulation of the nanophotonic grating coupler device indicates that it can be made compact (20 microm x 50 microm), low loss (3.8 dB), and broadband (100 nm). These couplers require subwavelength material modulation at the nanoscale to achieve the desired functionality. We show that optical proximity communication provides unmatched optical I/O bandwidth density to electrical chips, which enables the application of wavelength-division multiplexing point-to-point network in macrochip with unprecedented bandwidth-density. The envisioned physical implementation is discussed. The benefits of such an interconnect network include a 5-6x improvement in latency when compared to a purely electronic implementation. Performance analysis shows that the wavelength-division multiplexing point-to-point network offers better overall performance over other optical network architectures.
Wireless Inductive Power Device Suppresses Blade Vibrations
NASA Technical Reports Server (NTRS)
Morrison, Carlos R.; Provenza, Andrew J.; Choi, Benjamin B.; Bakhle, Milind A.; Min, James B.; Stefko, George L.; Duffy, Kirsten P.; Fougers, Alan J.
2011-01-01
Vibration in turbomachinery can cause blade failures and leads to the use of heavier, thicker blades that result in lower aerodynamic efficiency and increased noise. Metal and/or composite fatigue in the blades of jet engines has resulted in blade destruction and loss of lives. Techniques for suppressing low-frequency blade vibration, such as gtuned circuit resistive dissipation of vibratory energy, h or simply "passive damping," can require electronics incorporating coils of unwieldy dimensions and adding unwanted weight to the rotor. Other approaches, using vibration-dampening devices or damping material, could add undesirable weight to the blades or hub, making them less efficient. A wireless inductive power device (WIPD) was designed, fabricated, and developed for use in the NASA Glenn's "Dynamic Spin Rig" (DSR) facility. The DSR is used to simulate the functionality of turbomachinery. The relatively small and lightweight device [10 lb (approx.=4.5 kg)] replaces the existing venerable and bulky slip-ring. The goal is the eventual integration of this technology into actual turbomachinery such as jet engines or electric power generators, wherein the device will facilitate the suppression of potentially destructive vibrations in fan blades. This technology obviates slip rings, which require cooling and can prove unreliable or be problematic over time. The WIPD consists of two parts: a remote element, which is positioned on the rotor and provides up to 100 W of electrical power to thin, lightweight piezoelectric patches strategically placed on/in fan blades; and a stationary base unit that wirelessly communicates with the remote unit. The base unit supplies inductive power, and also acts as an input and output corridor for wireless measurement, and active control command to the remote unit. Efficient engine operation necessitates minimal disturbance to the gas flow across the turbine blades in any effort to moderate blade vibration. This innovation makes it possible to moderate vibration on or in turbomachinery blades by providing 100 W of wireless electrical power and actuation control to thin, lightweight vibration-suppressing piezoelectric patches (eight actuation and eight sensor patches in this prototype, for a total of 16 channels) positioned strategically on the surface of, or within, titanium fan blades, or embedded in composite fan blades. This approach moves significantly closer to the ultimate integration of "active" vibration suppression technology into jet engines and other turbomachinery devices such as turbine electrical generators used in the power industry. The novel feature of this device is in its utilization of wireless technology to simultaneously sense and actively control vibration in rotating or stationary turbomachinery blades using piezoelectric patches. In the past, wireless technology was used solely for sensing and diagnostics. This technology, however, will accomplish much more, in terms of simultaneously sensing, suppressing blade vibration, and making it possible for detailed study of vibration impact in turbomachinery blades.
Weber-Spickschen, T S; Oszwald, M; Westphal, R; Krettek, C; Wahl, F; Gosling, T
2010-01-01
Robot assisted fracture reduction of femoral shaft fractures provides precise alignment while reducing the amount of intraoperative imaging. The connection between the robot and the fracture fragment should allow conventional intramedullary nailing, be minimally invasive and provide interim fracture stability. In our study we tested three different reduction tools: a conventional External Fixator, a Reposition-Plate and a Three-Point-Device with two variations (a 40 degrees and a 90 degrees version). We measured relative movements between the tools and the bone fragments in all translation and rotation planes. The Three-Point-Device 90 degrees showed the smallest average relative displacement and was the only device able to withstand the maximum applied load of 70 Nm without failure of any bone fragment. The Three-Point-Device 90 degrees complies with all the stipulated requirements and is a suitable interface for robot assisted fracture reduction of femoral shaft fractures.
Method of and apparatus for determining deposition-point temperature
Mansure, A.J.; Spates, J.J.; Martin, S.J.
1998-10-27
Acoustic-wave sensor apparatus and method are disclosed for analyzing a normally liquid petroleum-based composition for monitoring deposition-point temperature. The apparatus includes at least one acoustic-wave device such as SAW, QCM, FPM, TSM or APM type devices in contact with the petroleum-based composition for sensing or detecting the surface temperature at which deposition occurs and/or rate of deposition as a function of temperature by sensing an accompanying change in frequency, phase shift, damping voltage or damping current of an electrical oscillator to a known calibrated condition. The acoustic wave device is actively cooled to monitor the deposition of constituents such as paraffins by determining the point at which solids from the liquid composition begin to form on the acoustic wave device. The acoustic wave device can be heated to melt or boil off the deposits to reset the monitor and the process can be repeated. 5 figs.
Method of and apparatus for determining deposition-point temperature
Mansure, Arthur J.; Spates, James J.; Martin, Stephen J.
1998-01-01
Acoustic-wave sensor apparatus and method for analyzing a normally liquid petroleum-based composition for monitoring deposition-point temperature. The apparatus includes at least one acoustic-wave device such as SAW, QCM, FPM, TSM or APM type devices in contact with the petroleum-based composition for sensing or detecting the surface temperature at which deposition occurs and/or rate of deposition as a function of temperature by sensing an accompanying change in frequency, phase shift, damping voltage or damping current of an electrical oscillator to a known calibrated condition. The acoustic wave device is actively cooled to monitor the deposition of constituents such as paraffins by determining the point at which solids from the liquid composition begin to form on the acoustic wave device. The acoustic wave device can be heated to melt or boil off the deposits to reset the monitor and the process can be repeated.
NASA Astrophysics Data System (ADS)
Smith, Suzanne; Sewart, Rene; Land, Kevin; Roux, Pieter; Gärtner, Claudia; Becker, Holger
2016-03-01
Lab-on-a-chip devices are often applied to point-of-care diagnostic solutions as they are low-cost, compact, disposable, and require only small sample volumes. For such devices, various reagents are required for sample preparation and analysis and, for an integrated solution to be realized, on-chip reagent storage and automated introduction are required. This work describes the implementation and characterization of effective liquid reagent storage and release mechanisms utilizing blister pouches applied to various point-of-care diagnostic device applications. The manufacturing aspects as well as performance parameters are evaluated.
Light Aircraft Piston Engine Carburetor Ice Detector/Warning Device Sensitivity/Effectiveness.
1982-06-01
10kHz max), converting raw data into engineering units as established by operator, displaying eight different parameters on cathode ray tube (CRT) and...TN No. 1790, February 1949. f. icing - Protection Requirements for Reciprocating Engine Induction Systems, NCA Technical Report No. 982, June 1949. q
40 CFR Appendix D to Subpart S of... - Steady-State Short Test Equipment
Code of Federal Regulations, 2011 CFR
2011-07-01
... range of low scale, for five minutes without adjustment. (7) Electromagnetic isolation and interference. Electromagnetic signals found in an automotive service environment shall not cause malfunctions or changes in the... vary as a result of electromagnetic radiation and induction devices normally found in the automotive...
40 CFR Appendix D to Subpart S of... - Steady-State Short Test Equipment
Code of Federal Regulations, 2013 CFR
2013-07-01
... range of low scale, for five minutes without adjustment. (7) Electromagnetic isolation and interference. Electromagnetic signals found in an automotive service environment shall not cause malfunctions or changes in the... vary as a result of electromagnetic radiation and induction devices normally found in the automotive...
40 CFR Appendix D to Subpart S of... - Steady-State Short Test Equipment
Code of Federal Regulations, 2014 CFR
2014-07-01
... range of low scale, for five minutes without adjustment. (7) Electromagnetic isolation and interference. Electromagnetic signals found in an automotive service environment shall not cause malfunctions or changes in the... vary as a result of electromagnetic radiation and induction devices normally found in the automotive...
40 CFR Appendix D to Subpart S of... - Steady-State Short Test Equipment
Code of Federal Regulations, 2010 CFR
2010-07-01
... range of low scale, for five minutes without adjustment. (7) Electromagnetic isolation and interference. Electromagnetic signals found in an automotive service environment shall not cause malfunctions or changes in the... vary as a result of electromagnetic radiation and induction devices normally found in the automotive...
40 CFR Appendix D to Subpart S of... - Steady-State Short Test Equipment
Code of Federal Regulations, 2012 CFR
2012-07-01
... range of low scale, for five minutes without adjustment. (7) Electromagnetic isolation and interference. Electromagnetic signals found in an automotive service environment shall not cause malfunctions or changes in the... vary as a result of electromagnetic radiation and induction devices normally found in the automotive...
A Fast Turn-Around Facility for Very Large Scale Integration (VLSI)
1982-06-01
statistics determination, the first test mask set will use the MATRIX chip design which was recently developed here at Stanford. This chip provides...reached when the basewidth is reduced to zero. Such devices, variably known as depleted- base transistors or bipolar static-induction transitors , have been
Far-infrared bandpass filters from cross-shaped grids
NASA Technical Reports Server (NTRS)
Tomaselli, V. P.; Edewaard, D. C.; Gillan, P.; Moller, K. D.
1981-01-01
The optical transmission characteristics of electroformed metal grids with inductive and capacitive cross patterns have been investigated in the far-infrared spectral region. The transmission characteristics of one- and two-grid devices are represented by transmission line theory parameters. Results are used to suggest construction guidelines for two-grid bandpass filters.
Study of Conical Pulsed Inductive Thruster with Multiple Modes of Operation
NASA Technical Reports Server (NTRS)
Miller, Robert; Eskridge, Richard; Martin, Adam; Rose, Frank
2008-01-01
An electrodeless, pulsed, inductively coupled thruster has several advantages over current electric propulsion designs. The efficiency of a pulsed inductive thruster is dependent upon the pulse characteristics of the device. Therefore, these thrusters are throttleable over a wide range of thrust levels by varying the pulse rate without affecting the thruster efficiency. In addition, by controlling the pulse energy and the mass bit together, the ISP of the thruster can also be varied with minimal efficiency loss over a wide range of ISP levels. Pulsed inductive thrusters will work with a multitude of propellants, including ammonia. Thus, a single pulsed inductive thruster could be used to handle a multitude of mission needs from high thrust to high ISP with one propulsion solution that would be variable in flight. A conical pulsed inductive lab thruster has been built to study this form of electric propulsion in detail. This thruster incorporates many advantages that are meant to enable this technology as a viable space propulsion technology. These advantages include incorporation of solid state switch technology for all switching needs of the thruster and pre-ionization of the propellant gas prior to acceleration. Pre-ionizing will significantly improve coupling efficiency between drive and bias fields and the plasma. This enables lower pulse energy levels without efficiency reduction. Pre-ionization can be accomplished at a small fraction of the drive pulse energy.
Kieback, D G; Zahradnik, H P; Quaas, L; Kröner-Fehmel, E E; Lippert, T H
1986-07-01
In an open randomized clinical trial 100 pregnant women with low Bishop Scores at term were treated either with intracervical Prostaglandin (PG) E2 (0.5 mg in 2.5 ml triacetin-gel) 12 hours before labor induction with intravenous oxytocin or with oxytocin infusion alone. In 46 of the 50 pretreated patients (92%) the Bishop Score progressed at least 3 points, in four cases only 2 points. The mean Bishop score in the untreated patients increased insignificantly. After PGE2-gel administration 16 patients delivered during the 12 hour interval compared to 3 in the group without pretreatment. The first induction attempt was successful in 14 (64%) of the 22 patients that were left to be induced after cervical softening and in 26 (57%) of the 47 women without cervical priming. The Cesarean section rate was 10% (n = 5) in the PGE2-gel group and 12% (n = 6) in the control group. Dosage of oxytocin required for labor induction was significantly lower after cervical softening. No serious fetal or maternal side effects were observed after PGE2 pretreatment.
Eddy-Current Sensors with Asymmetrical Point Spread Function
Gajda, Janusz; Stencel, Marek
2016-01-01
This paper concerns a special type of eddy-current sensor in the form of inductive loops. Such sensors are applied in the measuring systems classifying road vehicles. They usually have a rectangular shape with dimensions of 1 × 2 m, and are installed under the surface of the traffic lane. The wide Point Spread Function (PSF) of such sensors causes the information on chassis geometry, contained in the measurement signal, to be strongly averaged. This significantly limits the effectiveness of the vehicle classification. Restoration of the chassis shape, by solving the inverse problem (deconvolution), is also difficult due to the fact that it is ill-conditioned. An original approach to solving this problem is presented in this paper. It is a hardware-based solution and involves the use of inductive loops with an asymmetrical PSF. Laboratory experiments and simulation tests, conducted with models of an inductive loop, confirmed the effectiveness of the proposed solution. In this case, the principle applies that the higher the level of sensor spatial asymmetry, the greater the effectiveness of the deconvolution algorithm. PMID:27782033
Duan, Ming-Chao; Liu, Zhi-Long; Ge, Jian-Feng; Tang, Zhi-Jun; Wang, Guan-Yong; Wang, Zi-Xin; Guan, Dandan; Li, Yao-Yi; Qian, Dong; Liu, Canhua; Jia, Jin-Feng
2017-07-01
Superconducting thin films have been a focal point for intensive research efforts since their reduced dimension allows for a wide variety of quantum phenomena. Many of these films, fabricated in UHV chambers, are highly vulnerable to air exposure, making it difficult to measure intrinsic superconducting properties such as zero resistance and perfect diamagnetism with ex situ experimental techniques. Previously, we developed a multifunctional scanning tunneling microscope (MSTM) containing in situ four-point probe (4PP) electrical transport measurement capability in addition to the usual STM capabilities [Ge et al., Rev. Sci. Instrum. 86, 053903 (2015)]. Here we improve this MSTM via development of both transmission and reflection two-coil mutual inductance techniques for in situ measurement of the diamagnetic response of a superconductor. This addition does not alter the original STM and 4PP functions of the MSTM. We demonstrate the performance of the two-coil mutual inductance setup on a 10-nm-thick NbN thin film grown on a Nb-doped SrTiO 3 (111) substrate.
Eddy-Current Sensors with Asymmetrical Point Spread Function.
Gajda, Janusz; Stencel, Marek
2016-10-04
This paper concerns a special type of eddy-current sensor in the form of inductive loops. Such sensors are applied in the measuring systems classifying road vehicles. They usually have a rectangular shape with dimensions of 1 × 2 m, and are installed under the surface of the traffic lane. The wide Point Spread Function (PSF) of such sensors causes the information on chassis geometry, contained in the measurement signal, to be strongly averaged. This significantly limits the effectiveness of the vehicle classification. Restoration of the chassis shape, by solving the inverse problem (deconvolution), is also difficult due to the fact that it is ill-conditioned. An original approach to solving this problem is presented in this paper. It is a hardware-based solution and involves the use of inductive loops with an asymmetrical PSF. Laboratory experiments and simulation tests, conducted with models of an inductive loop, confirmed the effectiveness of the proposed solution. In this case, the principle applies that the higher the level of sensor spatial asymmetry, the greater the effectiveness of the deconvolution algorithm.
Infrared signal generation from AC induction field heating of graphite foam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klett, James W.; Rios, Orlando
A magneto-energy apparatus includes an electromagnetic field source for generating a time-varying electromagnetic field. A graphite foam conductor is disposed within the electromagnetic field. The graphite foam when exposed to the time-varying electromagnetic field conducts an induced electric current, the electric current heating the graphite foam to produce light. An energy conversion device utilizes light energy from the heated graphite foam to perform a light energy consuming function. A device for producing light and a method of converting energy are also disclosed.
NASA Astrophysics Data System (ADS)
Grube, R.; Tursky, W.; Gerzovskovits, S.; Schierz, W.
1982-12-01
An asymmetrical gate assisted turn-off thyristor and two types of rectifier diodes were developed. These devices are suitable for self-commutated convertors working at frequencies between 15 and 30 kHz for direct connection to 380 V and 500 V lines and for power outputs up to 20 kVA. Such convertors allow economic and easily controllable power supplies to be realized for applications such as welding, inductive heating, ultrasonic generators, and radar modulators.
Silicon device performance measurements to support temperature range enhancement
NASA Technical Reports Server (NTRS)
Johnson, R. Wayne; Askew, Ray; Bromstead, James; Weir, Bennett
1991-01-01
The results of the NPN bipolar transistor (BJT) (2N6023) breakdown voltage measurements were analyzed. Switching measurements were made on the NPN BJT, the insulated gate bipolar transistor (IGBT) (TA9796) and the N-channel metal oxide semiconductor field effect transistor (MOSFET) (RFH75N05E). Efforts were also made to build a H-bridge inverter. Also discussed are the plans that have been made to do life testing on the devices, to build an inductive switching test circuit and to build a dc/dc switched mode converter.
Garcia-Garcia, Hector M; McFadden, Eugène P; Farb, Andrew; Mehran, Roxana; Stone, Gregg W; Spertus, John; Onuma, Yoshinobu; Morel, Marie-Angèle; van Es, Gerrit-Anne; Zuckerman, Bram; Fearon, William F; Taggart, David; Kappetein, Arie-Pieter; Krucoff, Mitchell W; Vranckx, Pascal; Windecker, Stephan; Cutlip, Donald; Serruys, Patrick W
2018-06-12
The Academic Research Consortium (ARC)-2 initiative revisited the clinical and angiographic end point definitions in coronary device trials, proposed in 2007, to make them more suitable for use in clinical trials that include increasingly complex lesion and patient populations and incorporate novel devices such as bioresorbable vascular scaffolds. In addition, recommendations for the incorporation of patient-related outcomes in clinical trials are proposed. Academic Research Consortium-2 is a collaborative effort between academic research organizations in the United States and Europe, device manufacturers, and European, US, and Asian regulatory bodies. Several in-person meetings were held to discuss the changes that have occurred in the device landscape and in clinical trials and regulatory pathways in the last decade. The consensus-based end point definitions in this document are endorsed by the stakeholders of this document and strongly advocated for clinical trial purposes. This Academic Research Consortium-2 document provides further standardization of end point definitions for coronary device trials, incorporating advances in technology and knowledge. Their use will aid interpretation of trial outcomes and comparison among studies, thus facilitating the evaluation of the safety and effectiveness of these devices. © 2018 American Heart Association, Inc., and European Society of Cardiology.
[Clinical evaluation of propess for induction of term pregnancy].
Gai, Ming-ying; Zhang, Jian-ping; Li, Yang; Han, Hong-jing; Yang, Jian-qiu; Wang, Shan-mi; Su, Qi-feng; Wu, Lian-fang
2003-04-01
To explore the efficacy and safety of continuously released prostaglandin E(2) (PGE(2)) suppository-propess used for induction of term pregnancy. A multicenter, prospective, case control clinical study was carried out, propess was used in 100 cases as study group, the suppository without PGE(2) was used in 49 cases as control group. The cervical maturity (by Bishop scoring), the time to labor starting, membrane rupture and delivery, the application of oxytocin, ceserean section rate, fetal and neonatal condition were compared between 2 groups after inserting of the suppository. At the same time, side effects caused by propess were investigated. Bishop score was increased >or= 2 points in 93% cases, >or= 3 points in 87% cases in study group, whereas only 4% cases whose Bishop score increased >or= 2 points in control group. The time to labor starting, membrane rupture, and delivery was shortened obviously in study group than that in control group after inserting suppository. The application of oxytocin was much less in study group, cesarean section rate was reduced in study group (32% vs 61%). There was no significant difference between 2 groups in fetal and neonatal conditions. The overstimulation of uterine contraction and mild gastrointestinal tract reaction occurred in 3 cases and 2 cases respectively in study groups. Propess can be used for induction of term pregnancy effectively and safely.
Demonstration of a non-contact x-ray source using an inductively heated pyroelectric accelerator
NASA Astrophysics Data System (ADS)
Klopfer, Michael; Satchouk, Vladimir; Cao, Anh; Wolowiec, Thomas; Alivov, Yahya; Molloi, Sabee
2015-04-01
X-ray emission from pyroelectric sources can be produced through non-contact thermal cycling using induction heating. In this study, we demonstrated a proof of concept non-contact x-ray source powered via induction heating. An induction heater operating at 62.5 kHz provided a total of 6.5 W of delivered peak thermal power with 140 V DC of driving voltage. The heat was applied to a ferrous substrate mechanically coupled to a cubic 1 cm3 Lithium Niobate (LiNbO3) pyroelectric crystal maintained in a 3-12 mTorr vacuum. The maximum temperature reached was 175 °C in 86 s of heating. The cooling cycle began immediately after heating and was provided by passive radiative cooling. The total combined cycle time was 250 s. x-ray photons were produced and analyzed in both heating and cooling phases. Maximum photon energies of 59 keV and 55 keV were observed during heating and cooling, respectively. Non-contact devices such as this, may find applications in cancer therapy (brachytherapy), non-destructive testing, medical imaging, and physics education fields.
NASA Astrophysics Data System (ADS)
Yeh, Sheng-Kai; Chang, Heng-Chung; Fang, Weileun
2018-04-01
This study presents an inductive tactile sensor with a chrome steel ball sensing interface based on the commercially available standard complementary metal-oxide-semiconductor (CMOS) process (the TSMC 0.18 µm 1P6M CMOS process). The tactile senor has a deformable polymer layer as the spring of the device and no fragile suspended thin film structures are required. As a tactile force is applied on the chrome steel ball, the polymer would deform. The distance between the chrome steel ball and the sensing coil would changed. Thus, the tactile force can be detected by the inductance change of the sensing coil. In short, the chrome steel ball acts as a tactile bump as well as the sensing interface. Experimental results show that the proposed inductive tactile sensor has a sensing range of 0-1.4 N with a sensitivity of 9.22(%/N) and nonlinearity of 2%. Preliminary wireless sensing test is also demonstrated. Moreover, the influence of the process and material issues on the sensor performances have also been investigated.
Schormans, Matthew; Valente, Virgilio; Demosthenous, Andreas
2015-01-01
Inductive powering for implanted medical devices is a commonly employed technique, that allows for implants to avoid more dangerous methods such as the use of transcutaneous wires or implanted batteries. However, wireless powering in this way also comes with a number of difficulties and conflicting requirements, which are often met by using designs based on compromise. In particular, one aspect common to most inductive power links is that they are driven with a fixed frequency, which may not be optimal depending on factors such as coupling and load. In this paper, a method is proposed in which an inductive power link is driven by a frequency that is maintained at an optimum value f(opt), to ensure that the link is in resonance. In order to maintain this resonance, a phase tracking technique is employed at the primary side of the link; this allows for compensation of changes in coil separation and load. The technique is shown to provide significant improvements in maintained secondary voltage and efficiency for a range of loads when the link is overcoupled.
High-Performance Power-Semiconductor Packages
NASA Technical Reports Server (NTRS)
Renz, David; Hansen, Irving; Berman, Albert
1989-01-01
A 600-V, 50-A transistor and 1,200-V, 50-A diode in rugged, compact, lightweight packages intended for use in inverter-type power supplies having switching frequencies up to 20 kHz. Packages provide low-inductance connections, low loss, electrical isolation, and long-life hermetic seal. Low inductance achieved by making all electrical connections to each package on same plane. Also reduces high-frequency losses by reducing coupling into inherent shorted turns in packaging material around conductor axes. Stranded internal power conductors aid conduction at high frequencies, where skin effect predominates. Design of packages solves historical problem of separation of electrical interface from thermal interface of high-power semiconductor device.
Evaluation of induction motor performance using an electronic power factor controller
NASA Technical Reports Server (NTRS)
1978-01-01
The concept of reducing the losses in an induction motor by electronically controlling the time interval between the zero crossing of the applied voltage and the zero crossing of the armature current was evaluated. The effect on power losses and power factor of reducing the applied sinusoidal voltages below the rated value was investigated experimentally. The reduction in power losses was measured using an electronic controller designed and built at MSFC. Modifications to the MSFC controller are described as well as a manually controlled electronic device which does not require that the motor be wye connected and the neutral available. Possible energy savings are examined.
Numerical study of soap-film flow by nonuniform alternating electric fields
NASA Astrophysics Data System (ADS)
Nasiri, M.; Shirsavar, R.; Mollaei, S.; Ramos, A.
2017-02-01
Fluid flow of suspended liquid films induced by non-uniform alternating electric fields has been reported. The electric fields were generated by two rod-like electrodes perpendicular to the fluid surface. The observed fluid flow was explained qualitatively by considering a charge induction mechanism, where the electric field actuates on the charge induced on the film surface. In this paper we perform a numerical study of this fluid flow taking into account the charge induction mechanism. The numerical results are compared with experiments and good agreement is found. Finally, we propose the application of the device as a new kind of two dimensional fluid pump.
Numerical study of soap-film flow by nonuniform alternating electric fields.
Nasiri, M; Shirsavar, R; Mollaei, S; Ramos, A
2017-02-01
Fluid flow of suspended liquid films induced by non-uniform alternating electric fields has been reported. The electric fields were generated by two rod-like electrodes perpendicular to the fluid surface. The observed fluid flow was explained qualitatively by considering a charge induction mechanism, where the electric field actuates on the charge induced on the film surface. In this paper we perform a numerical study of this fluid flow taking into account the charge induction mechanism. The numerical results are compared with experiments and good agreement is found. Finally, we propose the application of the device as a new kind of two dimensional fluid pump.
Superconducting inductive displacement detection of a microcantilever
NASA Astrophysics Data System (ADS)
Vinante, A.
2014-07-01
We demonstrate a superconducting inductive technique to measure the displacement of a micromechanical resonator. In our scheme, a type I superconducting microsphere is attached to the free end of a microcantilever and approached to the loop of a dc Superconducting Quantum Interference Device (SQUID) microsusceptometer. A local magnetic field as low as 100 μT, generated by a field coil concentric to the SQUID, enables detection of the cantilever thermomechanical noise at 4.2 K. The magnetomechanical coupling and the magnetic spring are in good agreement with image method calculations assuming pure Meissner effect. These measurements are relevant to recent proposals of quantum magnetomechanics experiments based on levitating superconducting microparticles.
NASA Astrophysics Data System (ADS)
Permiakov, V.; Pulnikov, A.; Dupré, L.; De Wulf, M.; Melkebeek, J.
2003-05-01
In this article, the magnetic properties of nonoriented electrical steel under sinusoidal and distorted excitations are investigated for the whole range of unidirectional mechanical stresses. The distorted flux obtained from the tooth tip of 3 kW induction machine at no-load test was put into the measurement system. The total losses increase for compressive stress both under sinusoidal and distorted excitations. For tensile elastic stresses, the total losses first decrease and then increase in a very similar way for both excitations. In contrast, the difference between total losses under sinusoidal and distorted magnetic fluxes becomes smaller with increase of the plastic strain. This work is a serious step toward complete characterization of the magnetic properties of electrical steel in the teeth area of induction machines. A deeper insight of that problem can improve the design of induction machines and other electromagnetic devices.
Overview of magnetic suspension research at Langley Research Center
NASA Technical Reports Server (NTRS)
Groom, Nelson J.
1992-01-01
An overview of research in small- and large-gap magnetic suspension systems at LaRC is presented. The overview is limited to systems which have been built as laboratory models or engineering models. Small-gap systems applications include the Annular Momentum Control Device (AMCD), which is a momentum storage device for the stabilization and control of spacecraft, and the Annular Suspension and Pointing System (ASPS), which is a general purpose pointing mount designed to provide orientation, mechanical isolation, and fine pointing space experiments. These devices are described and control and linearization approaches for the magnetic suspension systems for these devices are discussed. Large-gap systems applications at LaRC have been almost exclusively wind tunnel magnetic suspension systems. A brief description of these efforts is also presented.
Modeling and testing of ethernet transformers
NASA Astrophysics Data System (ADS)
Bowen, David
2011-12-01
Twisted-pair Ethernet is now the standard home and office last-mile network technology. For decades, the IEEE standard that defines Ethernet has required electrical isolation between the twisted pair cable and the Ethernet device. So, for decades, every Ethernet interface has used magnetic core Ethernet transformers to isolate Ethernet devices and keep users safe in the event of a potentially dangerous fault on the network media. The current state-of-the-art Ethernet transformers are miniature (<5mm diameter) ferrite-core toroids wrapped with approximately 10 to 30 turns of wire. As small as current Ethernet transformers are, they still limit further Ethernet device miniaturization and require a separate bulky package or jack housing. New coupler designs must be explored which are capable of exceptional miniaturization or on-chip fabrication. This dissertation thoroughly explores the performance of the current commercial Ethernet transformers to both increase understanding of the device's behavior and outline performance parameters for replacement devices. Lumped element and distributed circuit models are derived; testing schemes are developed and used to extract model parameters from commercial Ethernet devices. Transfer relation measurements of the commercial Ethernet transformers are compared against the model's behavior and it is found that the tuned, distributed models produce the best transfer relation match to the measured data. Process descriptions and testing results on fabricated thin-film dielectric-core toroid transformers are presented. The best results were found for a 32-turn transformer loaded with 100Ω, the impedance of twisted pair cable. This transformer gave a flat response from about 10MHz to 40MHz with a height of approximately 0.45. For the fabricated transformer structures, theoretical methods to determine resistance, capacitance and inductance are presented. A special analytical and numerical analysis of the fabricated transformer inductance is presented. Planar cuts of magnetic slope fields around the dielectric-core toroid are shown that describe the effect of core height and winding density on flux uniformity without a magnetic core.
Electrical power generating system
NASA Technical Reports Server (NTRS)
Nola, F. J. (Inventor)
1983-01-01
A power generating system for adjusting coupling an induction motor, as a generator, to an A.C. power line wherein the motor and power line are connected through a triac is described. The triac is regulated to normally turn on at a relatively late point in each half cycle of its operation, whereby at less than operating speed, and thus when the induction motor functions as a motor rather than as a generator, power consumption from the line is substantially reduced.
NASA Astrophysics Data System (ADS)
Quamruzzaman, M.; Mohammad, Nur; Matin, M. A.; Alam, M. R.
2016-10-01
Solar photovoltaics (PVs) have nonlinear voltage-current characteristics, with a distinct maximum power point (MPP) depending on factors such as solar irradiance and operating temperature. To extract maximum power from the PV array at any environmental condition, DC-DC converters are usually used as MPP trackers. This paper presents the performance analysis of a coupled inductor single-ended primary inductance converter for maximum power point tracking (MPPT) in a PV system. A detailed model of the system has been designed and developed in MATLAB/Simulink. The performance evaluation has been conducted on the basis of stability, current ripple reduction and efficiency at different operating conditions. Simulation results show considerable ripple reduction in the input and output currents of the converter. Both the MPPT and converter efficiencies are significantly improved. The obtained simulation results validate the effectiveness and suitability of the converter model in MPPT and show reasonable agreement with the theoretical analysis.
Zahradnik, H P; Quaas, L; Kröner-Fehmel, E E; Kieback, D G; Lippert, T H
1987-03-01
In an open randomized clinical study, 50 of 100 gravidae with a low Bishop score (less than or equal to 5) at term were treated with prostaglandin E2 (0.5 mg PGE2 in 2.5 ml Triacetin gel. Prepidil, intracervically) 12 hours before the indicated i.v. oxytocin induction. In 50 patients labor was induced intravenously without any pretreatment. In 46 of 50 pretreated women (92%) there was an increase in the Bishop score of at least three points, and of only two points in the remaining four. In the control group no significant increase in the Bishop score was measurable. Sixteen patients delivered within the first 12 hours after PGE2 gel administration, before oxytocin induction. Three women in the untreated control group also delivered during this pre-observation period. In 14 (64%) of 22 women in whom cervical priming with PGE2 was performed and 26 (57%) of 47 patients in whom it was not the first intravenous oxytocin induction was successful. The frequency of cesarean sections was 10% (n = 5) in the PGE2 gel group and 12% (n = 6) in the oxytocin group. The oxytocin dose needed to induce labor was significantly lower after cervical priming. No severe side effects were observed during and after PGE2 treatment, in either the mothers or the children.
Leclercq, Amélie; Nonell, Anthony; Todolí Torró, José Luis; Bresson, Carole; Vio, Laurent; Vercouter, Thomas; Chartier, Frédéric
2015-07-23
Inductively coupled plasma optical emission spectrometry (ICP-OES) and mass spectrometry (ICP-MS) are increasingly used to carry out analyses in organic/hydro-organic matrices. The introduction of such matrices into ICP sources is particularly challenging and can be the cause of numerous drawbacks. This tutorial review, divided in two parts, explores the rich literature related to the introduction of organic/hydro-organic matrices in ICP sources. Part I provided theoretical considerations associated with the physico-chemical properties of such matrices, in an attempt to understand the induced phenomena. Part II of this tutorial review is dedicated to more practical considerations on instrumentation, instrumental and operating parameters, as well as analytical strategies for elemental quantification in such matrices. Two important issues are addressed in this part: the first concerns the instrumentation and optimization of instrumental and operating parameters, pointing out (i) the description, benefits and drawbacks of different kinds of nebulization and desolvation devices and the impact of more specific instrumental parameters such as the injector characteristics and the material used for the cone; and, (ii) the optimization of operating parameters, for both ICP-OES and ICP-MS. Even if it is at the margin of this tutorial review, Electrothermal Vaporization and Laser Ablation will also be shortly described. The second issue is devoted to the analytical strategies for elemental quantification in such matrices, with particular insight into the isotope dilution technique, particularly used in speciation analysis by ICP-coupled separation techniques. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Bodner, G. M.; Bongard, M. W.; Fonck, R. J.; Perry, J. M.; Reusch, J. A.; Rodriguez Sanchez, C.
2017-10-01
Understanding the electron confinement of local helicity injection (LHI) is critical in order to evaluate its scalability as a startup technique to MA-class devices. Electron confinement in the Pegasus Toroidal Experiment is investigated using multi-point Thomson scattering (TS). The Pegasus TS system utilizes a set of high-throughput transmission gratings and intensified CCDs to measure Te and ne profiles. Previous TS measurements indicated peaked Te profiles 120 eV in outboard injector discharges characterized by strong inductive drive and low LHI drive. Injectors designed to have dominant non-inductive drive have recently been installed in the divertor region of Pegasus to understand the relationship between effective drive voltage, Veff, and plasma performance. At low Veff and reduced plasma current, Ip 60 kA, TS measurements reveal a flat Te profile 50 eV, with a peaked ne profile 1 ×1019 m-3, resulting in a slightly peaked pe profile. As current drive is increased, the Te profiles become hollow with a core Te 50 eV and an edge Te 120 -150 eV. These hollow profiles appear after the start of the Ip flattop and are sustained until the discharge terminates. The ne profiles drop in magnitude to < 1 ×1019 m-3 but remain somewhat peaked. Initial results suggest a weak scaling between input power and core Te. Additional studies are planned to identify the mechanisms behind the anomalous profile features. Work supported by US DOE Grant DE-FG02-96ER54375.
Kencana, Andy Prima; Heng, John
2008-11-01
This paper introduces a novel passive tongue control and tracking device. The device is intended to be used by the severely disabled or quadriplegic person. The main focus of this device when compared to the other existing tongue tracking devices is that the sensor employed is passive which means it requires no powered electrical sensor to be inserted into the user's mouth and hence no trailing wires. This haptic interface device employs the use of inductive sensors to track the position of the user's tongue. The device is able perform two main PC functions that of the keyboard and mouse function. The results show that this device allows the severely disabled person to have some control in his environment, such as to turn on and off or control daily electrical devices or appliances; or to be used as a viable PC Human Computer Interface (HCI) by tongue control. The operating principle and set-up of such a novel passive tongue HCI has been established with successful laboratory trials and experiments. Further clinical trials will be required to test out the device on disabled persons before it is ready for future commercial development.
Development of Curie point switching for thin film, random access, memory device
NASA Technical Reports Server (NTRS)
Lewicki, G. W.; Tchernev, D. I.
1967-01-01
Managanese bismuthide films are used in the development of a random access memory device of high packing density and nondestructive readout capability. Memory entry is by Curie point switching using a laser beam. Readout is accomplished by microoptical or micromagnetic scanning.
Quality of life and handling experience with the PROSE device: an Indian scenario.
Bhattacharya, Pradipta; Mahadevan, Rajeswari
2017-11-01
PROSE (prosthetic replacement of ocular surface ecosystem) device is a custom-designed, corneal vaulting scleral contact lens, which is used in the treatment of irregular corneal conditions to improve vision and comfort. The present study aimed at assessing the success of the PROSE device in an Indian scenario in terms of change in quality of life and to understand the handling issues related to the device use. Thirty-two subjects with various irregular corneal conditions meeting the inclusion criteria were included in the study. Subjects were followed for three months after dispensing the PROSE device. Subjects' demographic details, high and low contrast visual acuity with habitual correction and PROSE device, Visual Function Questionnaire scores (NEI VFQ-25) and Ocular Surface Disease Index (OSDI) scores pre- and post-PROSE treatment were collected and compared. An indigenously developed questionnaire was also administered during the follow-up visit for assessing the handling-related issues faced by the subjects while using the device. Forty eyes of 32 subjects were included in the study, of whom 30 reported for follow-up. The median NEI VFQ-25 score improved from 47.33 points to 77.27 points over a period of three months, which was statistically significant (p < 0.05). There was a statistically significant decrease in median OSDI score from 51.14 points to 13.63 points post-PROSE treatment (p < 0.05). Subjects reported no or very minimal handling-related difficulties associated with the use of the PROSE device. The PROSE treatment can be an effective mode of managing patients with irregular corneal conditions and significantly improved the vision-related quality of life of patients suffering from these conditions. The handling of the device is easy and can be mastered with adequate training. © 2017 Optometry Australia.
NASA Technical Reports Server (NTRS)
Hallock, Ashley; Polzin, Kurt; Emsellem, Gregory
2012-01-01
Pulsed inductive plasma thrusters [1-3] are spacecraft propulsion devices in which electrical energy is capacitively stored and then discharged through an inductive coil. The thruster is electrodeless, with a time-varying current in the coil interacting with a plasma covering the face of the coil to induce a plasma current. Propellant is accelerated and expelled at a high exhaust velocity (O(10-100 km/s)) by the Lorentz body force arising from the interaction of the magnetic field and the induced plasma current. While this class of thruster mitigates the life-limiting issues associated with electrode erosion, pulsed inductive plasma thrusters require high pulse energies to inductively ionize propellant. The Microwave Assisted Discharge Inductive Plasma Accelerator (MAD-IPA) [4, 5] is a pulsed inductive plasma thruster that addressees this issue by partially ionizing propellant inside a conical inductive coil via an electron cyclotron resonance (ECR) discharge. The ECR plasma is produced using microwaves and permanent magnets that are arranged to create a thin resonance region along the inner surface of the coil, restricting plasma formation, and in turn current sheet formation, to a region where the magnetic coupling between the plasma and the inductive coil is high. The use of a conical theta-pinch coil is under investigation. The conical geometry serves to provide neutral propellant containment and plasma plume focusing that is improved relative to the more common planar geometry of the Pulsed Inductive Thruster (PIT) [2, 3], however a conical coil imparts a direct radial acceleration of the current sheet that serves to rapidly decouple the propellant from the coil, limiting the direct axial electromagnetic acceleration in favor of an indirect acceleration mechanism that requires significant heating of the propellant within the volume bounded by the current sheet. In this paper, we describe thrust stand measurements performed to characterize the performance (specific impulse, thrust efficiency) of the MAD-IPA thruster. Impulse data are obtained at various pulse energies, mass flow rates and inductive coil. geometries. Dependencies on these experimental parameters are discussed in the context of the current sheet formation and electromagnetic plasma acceleration processes.
Laboratory-Model Integrated-System FARAD Thruster
NASA Technical Reports Server (NTRS)
Polzin, K.A.; Best, S.; Miller, R.; Rose, M.F.; Owens, T.
2008-01-01
Pulsed inductive plasma accelerators are spacecraft propulsion devices in which energy is stored in a capacitor and then discharged through an inductive coil. The device is electrodeless, inducing a plasma current sheet in propellant located near the face of the coil. The propellant is accelerated and expelled at a high exhaust velocity (order of 10 km/s) through the interaction of the plasma current with an induced magnetic field. The Faraday Accelerator with RF-Assisted Discharge (FARAD) thruster [1,2] is a type of pulsed inductive plasma accelerator in which the plasma is preionized by a mechanism separate from that used to form the current sheet and accelerate the gas. Employing a separate preionization mechanism in this manner allows for the formation of an inductive current sheet at much lower discharge energies and voltages than those found in previous pulsed inductive accelerators like the Pulsed Inductive Thruster (PIT). In a previous paper [3], the authors presented a basic design for a 100 J/pulse FARAD laboratory-version thruster. The design was based upon guidelines and performance scaling parameters presented in Refs. [4, 5]. In this paper, we expand upon the design presented in Ref. [3] by presenting a fully-assembled and operational FARAD laboratory-model thruster and addressing system and subsystem-integration issues (concerning mass injection, preionization, and acceleration) that arose during assembly. Experimental data quantifying the operation of this thruster, including detailed internal plasma measurements, are presented by the authors in a companion paper [6]. The thruster operates by first injecting neutral gas over the face of a flat, inductive acceleration coil and at some later time preionizing the gas. Once the gas is preionized current is passed through the acceleration coil, inducing a plasma current sheet in the propellant that is accelerated away from the coil through electromagnetic interaction with the time-varying magnetic field. Neutral gas is injected over the face of the acceleration coil through a fast-acting valve that feeds a central distribution manifold. The thruster is designed to preionize the gas using an RF-frequency ringing signal produced by a discharging Vector Inversion Generator (VIG). The acceleration stage consists of a multiple-turn, multiple-strand spiral induction coil (see Fig. 1, left panel) and is designed for operation at discharge energies on the order of 100 J/pulse. Several different pulsed power train modules can be used to drive current through the acceleration coil. One such power train is based upon the Bernardes and Merryman circuit topology, which restricts voltage reversal on the capacitor banks and can be clamped to eliminate current reversal in the coil. A second option is a pulse-compression-ring power train (see Fig. 1, right panel), which takesa temporally broad, low current pulse and transforms it into a short, high current pulse.
NASA Astrophysics Data System (ADS)
Wehner, William; Schuster, Eugenio; Poli, Francesca
2016-10-01
Initial progress towards the design of non-inductive current ramp-up scenarios in the National Spherical Torus Experiment Upgrade (NSTX-U) has been made through the use of TRANSP predictive simulations. The strategy involves, first, ramping the plasma current with high harmonic fast waves (HHFW) to about 400 kA, and then further ramping to 900 kA with neutral beam injection (NBI). However, the early ramping of neutral beams and application of HHFW leads to an undesirably peaked current profile making the plasma unstable to ballooning modes. We present an optimization-based control approach to improve on the non-inductive ramp-up strategy. We combine the TRANSP code with an optimization algorithm based on sequential quadratic programming to search for time evolutions of the NBI powers, the HHFW powers, and the line averaged density that define an open-loop actuator strategy that maximizes the non-inductive current while satisfying constraints associated with the current profile evolution for MHD stable plasmas. This technique has the potential of playing a critical role in achieving robustly stable non-inductive ramp-up, which will ultimately be necessary to demonstrate applicability of the spherical torus concept to larger devices without sufficient room for a central coil. Supported by the US DOE under the SCGSR Program.
Electrically Driven Photonic Crystal Nanocavity Devices
2012-01-01
material, here gallium arsenide and indium arsenide self- assembled quantum dots (QDs). QDs are preferred for the gain medium because they can have...blue points ) and 150 K (green points ). The black lines are linear fits to the above threshold output power of the lasers, which are used to find the...SHAMBAT et al.: ELECTRICALLY DRIVEN PHOTONIC CRYSTAL NANOCAVITY DEVICES 1707 Fig. 13. (a) Tilted SEM picture of a fabricated triple cavity device. The in
Optical Docking Aid Containing Fresnel Lenses
NASA Technical Reports Server (NTRS)
Pierce, Cole J.
1995-01-01
Proposed device provides self-contained visual cues to aid in docking. Similar to devices used to guide pilots in landing on aircraft carriers. Positions and directions of beams of light give observer visual cues of position relative to docking target point. Optical assemblies generate directed, diverging beams of light that, together, mark approach path to docking point. Conceived for use in docking spacecraft at Space Station Freedom, device adapted to numerous industrial docking and alignment applications.
Cholesterol Point-of-Care Testing for Community Pharmacies: A Review of the Current Literature.
Haggerty, Lauren; Tran, Deanna
2017-08-01
To summarize the literature on cholesterol point-of-care tests (POCTs). This article would serve as a resource to assist community pharmacists in developing cholesterol point-of-care (POC) pharmacy services. A literature search was performed in MEDLINE Ovid, PubMed, EMBASE, and Cochrane database using the following medical subject headings (MeSH) terms: point-of-care test, cholesterol, blood chemical analysis, rapid testing, collaborative practice, community pharmacy, and ambulatory care. Additional resources including device manufacturer web sites were summarized to supplement the current literature. All human research articles, review articles, meta-analyses, and abstracts published in English through September 1, 2014, were considered. A total of 36 articles were applicable for review. Information was divided into the following categories to be summarized: devices, pharmacists' impact, and operational cost for the pharmacy. The current literature suggests that POCTs in community pharmacies assist with patient outcomes by providing screenings and referring patients with dyslipidemia for further evaluation. The majority of studies on cholesterol POC devices focused on accuracy, revealing the need for further studies to develop best practices and practice models with successful reimbursement. Accuracy, device specifications, required supplies, and patient preference should be considered when selecting a POC device for purchase.
Induction as Knowledge Integration
NASA Technical Reports Server (NTRS)
Smith, Benjamin D.; Rosenbloom, Paul S.
1996-01-01
Two key issues for induction algorithms are the accuracy of the learned hypothesis and the computational resources consumed in inducing that hypothesis. One of the most promising ways to improve performance along both dimensions is to make use of additional knowledge. Multi-strategy learning algorithms tackle this problem by employing several strategies for handling different kinds of knowledge in different ways. However, integrating knowledge into an induction algorithm can be difficult when the new knowledge differs significantly from the knowledge the algorithm already uses. In many cases the algorithm must be rewritten. This paper presents Knowledge Integration framework for Induction (KII), a KII, that provides a uniform mechanism for integrating knowledge into induction. In theory, arbitrary knowledge can be integrated with this mechanism, but in practice the knowledge representation language determines both the knowledge that can be integrated, and the costs of integration and induction. By instantiating KII with various set representations, algorithms can be generated at different trade-off points along these dimensions. One instantiation of KII, called RS-KII, is presented that can implement hybrid induction algorithms, depending on which knowledge it utilizes. RS-KII is demonstrated to implement AQ-11, as well as a hybrid algorithm that utilizes a domain theory and noisy examples. Other algorithms are also possible.
Frerk, C.; Mitchell, V. S.; McNarry, A. F.; Mendonca, C.; Bhagrath, R.; Patel, A.; O'Sullivan, E. P.; Woodall, N. M.; Ahmad, I.
2015-01-01
These guidelines provide a strategy to manage unanticipated difficulty with tracheal intubation. They are founded on published evidence. Where evidence is lacking, they have been directed by feedback from members of the Difficult Airway Society and based on expert opinion. These guidelines have been informed by advances in the understanding of crisis management; they emphasize the recognition and declaration of difficulty during airway management. A simplified, single algorithm now covers unanticipated difficulties in both routine intubation and rapid sequence induction. Planning for failed intubation should form part of the pre-induction briefing, particularly for urgent surgery. Emphasis is placed on assessment, preparation, positioning, preoxygenation, maintenance of oxygenation, and minimizing trauma from airway interventions. It is recommended that the number of airway interventions are limited, and blind techniques using a bougie or through supraglottic airway devices have been superseded by video- or fibre-optically guided intubation. If tracheal intubation fails, supraglottic airway devices are recommended to provide a route for oxygenation while reviewing how to proceed. Second-generation devices have advantages and are recommended. When both tracheal intubation and supraglottic airway device insertion have failed, waking the patient is the default option. If at this stage, face-mask oxygenation is impossible in the presence of muscle relaxation, cricothyroidotomy should follow immediately. Scalpel cricothyroidotomy is recommended as the preferred rescue technique and should be practised by all anaesthetists. The plans outlined are designed to be simple and easy to follow. They should be regularly rehearsed and made familiar to the whole theatre team. PMID:26556848
NASA Astrophysics Data System (ADS)
Sato, Daiki; Saitoh, Hiroumi
This paper proposes a new control method for reducing fluctuation of power system frequency through smoothing active power output of wind farm. The proposal is based on the modulation of rotaional kinetic energy of variable speed wind power generators through power converters between permanent magnet synchronous generators (PMSG) and transmission lines. In this paper, the proposed control is called Fluctuation Absorption by Flywheel Characteristics control (FAFC). The FAFC can be easily implemented by adding wind farm output signal to Maximum Power Point Tracking control signal through a feedback control loop. In order to verify the effectiveness of the FAFC control, a simulation study was carried out. In the study, it was assumed that the wind farm consisting of PMSG type wind power generator and induction machine type wind power generaotors is connected with a power sysem. The results of the study show that the FAFC control is a useful method for reducing the impacts of wind farm output fluctuation on system frequency without additional devices such as secondary battery.
First Plasma Results from the HIT-SI Spheromak
NASA Astrophysics Data System (ADS)
Sieck, P. E.; Hamp, W. T.; Izzo, V. A.; Jarboe, T. R.; Nelson, B. A.; O'Neill, R. G.; Redd, A. J.; Smith, R. J.
2003-10-01
HIT-SI is the newest device in the Helicity Injected Torus (HIT) program. HIT-SI is a ``bow tie'' spheromak formed and sustained by Steady Inductive Helicity Injection (SIHI) current drive. SIHI injects helicity at a nearly constant rate with no open field lines intersecting the boundary. (T. R. Jarboe, Fusion Technology 36) (1), p. 85, 1999 HIT-SI has been designed with a bow tie geometry to achieve stable high-β (>10%) spheromak equilibria. (U. Shumlak and T. R. Jarboe, Phys. Plasmas 7) (7), p. 2959, 2000 Diagnostics currently include surface magnetic probes and flux loops, visible light imaging, H-alpha line radiation monitors, voltage measurements across insulating breaks, injector current Rogowski coils, and injector flux loops. HIT-SI is currently operating in parallel with experiments on HIT-II. At the conclusion of HIT-II operations, HIT-SI will inherit a multi-point Thomson Scattering system, a scanning two-chord FIR interferometer, and other advanced diagnostics, as well as more power supplies to extend the discharge duration. Results are presented which characterize injector operation and possible evidence for spheromak formation.
Hammoud, Abbas; Chamseddine, Ahmad; Nguyen, Dang K; Sawan, Mohamad
2016-08-01
The need of continuous real-time monitoring device for in-vivo drug level detection has been widely articulated lately. Such monitoring could guide drug posology and timing of intake, detect low or high drug levels, in order to take adequate measures, and give clinicians a valuable window into patients' health and their response to therapeutics. This paper presents a novel implantable bio-sensor based on impedance measurement capable of continuously monitoring various antiepileptic drug levels. This portable point-of-care microsystem replaces large and stationary conventional macrosystems, and is a one of a kind system designed with an array of electrodes to monitor various anti-epileptic drugs rather than one drug. The micro-system consists of (i) the front-end circuit including an inductive coil to receive energy from an external base station, and to exchange data with the latter; (ii) the power management block; (iii) the readout and control block; and (iv) the biosensor array. The electrical circuitry was designed using the 0.18-um CMOS process technology intended to be miniature and consume ultra-low power.
HOME TREATMENT DEVICES - MICROBIOLOGY OF POINT OF USE AND POINT OF ENTRY DEVICES
Consumer concerns over the quality of their drinking water have increased steadily over the past 15-20 years. This is primarily due to the perception of consumers, significantly influenced by news media reports, that contaminants (chemical and microbiological) in municipal drinki...
Inertial fusion energy target injection, tracking, and beam pointing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petzoldt, Ronald Wayne
1995-03-07
Several cryogenic targets must be injected each second into a reaction chamber. Required target speed is about 100 m/s. Required accuracy of the driver beams on target is a few hundred micrometers. Fuel strength is calculated to allow acceleration in excess of 10,000 m/s 2 if the fuel temperature is less than 17 K. A 0.1 μm thick dual membrane will allow nearly 2,000 m/s 2 acceleration. Acceleration is gradually increased and decreased over a few membrane oscillation periods (a few ms), to avoid added stress from vibrations which could otherwise cause a factor of two decrease in allowed acceleration.more » Movable shielding allows multiple targets to be in flight toward the reaction chamber at once while minimizing neutron heating of subsequent targets. The use of multiple injectors is recommended for redundancy which increases availability and allows a higher pulse rate. Gas gun, rail gun, induction accelerator, and electrostatic accelerator target injection devices are studied, and compared. A gas gun is the preferred device for indirect-drive targets due to its simplicity and proven reliability. With the gas gun, the amount of gas required for each target (about 10 to 100 mg) is acceptable. A revolver loading mechanism is recommended with a cam operated poppet valve to control the gas flow. Cutting vents near the muzzle of the gas gun barrel is recommended to improve accuracy and aid gas pumping. If a railgun is used, we recommend an externally applied magnetic field to reduce required current by an order of magnitude. Optical target tracking is recommended. Up/down counters are suggested to predict target arrival time. Target steering is shown to be feasible and would avoid the need to actively point the beams. Calculations show that induced tumble from electrostatically steering the target is not excessive.« less
Venturini, Joseph M; Retzer, Elizabeth M; Estrada, J Raider; Mediratta, Anuj; Friant, Janet; Nathan, Sandeep; Paul, Jonathan D; Blair, John; Lang, Roberto M; Shah, Atman P
2016-10-01
Patent foramen ovale (PFO) has been linked to cryptogenic stroke, and closure has been reported to improve clinical outcomes. However, there are no clear guidelines to direct device sizing. This study sought to use patient characteristics and echocardiographic findings to create a prediction score for device sizing. This was a retrospective review of patients undergoing percutaneous PFO closure at our institution between July 2010 and December 2014. Demographic and clinical characteristics were recorded, and all pre- and intraprocedural echocardiography results were evaluated. Thirty-six patients underwent percutaneous PFO closure during the study period. All procedures were performed using an Amplatzer Septal Occluder "Cribriform" (ASOC) device in one of three disc diameters: 25, 30, or 35 mm. Closure was indicated for cryptogenic stroke/transient ischemic attack in 75% of cases. Every case (100%) was successful with durable shunt correction at the 6-month follow-up without complications of erosion or device embolization. The presence of atrial septal aneurysm (ASA) ( p = 0.027) and PFO tunnel length >10 mm ( p = 0.038) were independently associated with increased device size. A scoring system of 1 point for male sex, 1 point for ASA, and 1 point for PFO tunnel >10 mm long was associated with the size of closure device implanted ( p = 0.006). A simple scoring system may be used to select an optimally sized device for percutaneous PFO closure using the ASOC device.
The ideal chip is not enough: Issues retarding the success of wide band-gap devices
NASA Astrophysics Data System (ADS)
Kaminski, Nando
2017-04-01
Semiconductor chips made from the wide band-gap (WBG) materials silicon carbide (SiC) or gallium nitride (GaN) are already approaching the theoretical limits given by the respective materials. Unfortunately, their advantages over silicon devices cannot be fully exploited due to limitations imposed by the device packaging or the circuitry around the semiconductors. Stray inductances slow down the switching speed and increase losses, packaging materials limit the maximum temperature and the maximum useful temperature swing, and passives limit the maximum switching frequency. All these issues have to be solved or at least minimised to make WBG attractive for a wider range of applications and, consequently, to profit from the economy of scale.
Wireless energy transfer platform for medical sensors and implantable devices.
Zhang, Fei; Hackworth, Steven A; Liu, Xiaoyu; Chen, Haiyan; Sclabassi, Robert J; Sun, Mingui
2009-01-01
Witricity is a newly developed technique for wireless energy transfer. This paper presents a frequency adjustable witricity system to power medical sensors and implantable devices. New witricity resonators are designed for both energy transmission and reception. A prototype platform is described, including an RF power source, two resonators with new structures, and inductively coupled input and output stages. In vitro experiments, both in open air and using a human head phantom consisting of simulated tissues, are employed to verify the feasibility of this platform. An animal model is utilized to evaluate in vivo energy transfer within the body of a laboratory pig. Our experiments indicate that witricity is an effective new tool for providing a variety of medical sensors and devices with power.
Normal-incidence quantum cascade detector coupled by nanopore structure
NASA Astrophysics Data System (ADS)
Liu, Jianqi; Wang, Fengjiao; Zhai, Shenqiang; Zhang, Jinchuan; Liu, Shuman; Liu, Junqi; Wang, Lijun; Liu, Fengqi; Wang, Zhanguo
2018-04-01
A normal-incidence quantum cascade detector coupled by a nanopore array structure (NPS) is demonstrated. The NPS is fabricated on top of an In0.53Ga0.47As contact layer by inductively coupled plasma etching using anodic aluminum oxide as a mask. Because of the nonuniform volume fraction at different areas of the device mesa, the NPS acts as subwavelength random gratings. Normal-incidence light can be scattered into random oblique directions for inter-sub-band transition absorption. With normal incidence, the responsivities of the device reach 24 mA/W at 77 K and 15.7 mA/W at 300 K, which are enhanced 2.23 and 1.96 times, respectively, compared with that of the 45°-edge device.
NASA Astrophysics Data System (ADS)
Cano, M. E.; Barrera, A.; Estrada, J. C.; Hernandez, A.; Cordova, T.
2011-11-01
The development of a device for generating ac magnetic fields based on a resonant inverter is presented, which has been specially designed to carry out experiments of magnetic hyperthermia. By determining the electric current in the LC resonant circuit, a maximum intensity of magnetic field around of 15 mT is calculated, with a frequency around of 206 kHz. This ac magnetic field is able to heat powdered magnetic materials embedded in biological systems to be used in biomedical applications. Indeed, in order to evaluate the sensitivity of the device we also present the measurements of the specific absorption rate in phantoms performed with commercially prepared Fe3O4 and distilled water at different concentrations.
Educational Electrical Appliance Power Meter and Logger
ERIC Educational Resources Information Center
Nunn, John
2013-01-01
The principles behind two different designs of inductive power meter are presented. They both make use of the microphone input of a computer which, together with a custom-written program, can record the instantaneous power of a domestic electrical appliance. The device can be built quickly and can be calibrated with reference to a known power…
36 CFR Appendix B to Part 1191 - Americans With Disabilities Act: Scoping
Code of Federal Regulations, 2014 CFR
2014-07-01
... of Sport Activity. That portion of a room or space where the play or practice of a sport occurs..., receivers, and coupling devices to bypass the acoustical space between a sound source and a listener by means of induction loop, radio frequency, infrared, or direct-wired equipment. Boarding Pier. A portion...
Bringing Abstract Academic Integrity and Ethical Concepts into Real-Life Situations
ERIC Educational Resources Information Center
Kwong, Theresa; Wong, Eva; Yue, Kevin
2017-01-01
This paper reports the learning analytics on the initial stages of a large-scale, government-funded project which inducts university students in Hong Kong into consideration of academic integrity and ethics through mobile Augmented Reality (AR) learning trails--Trails of Integrity and Ethics (TIEs)--accessed on smart devices. The trails immerse…
Sandborn, William J; Rutgeerts, Paul; Enns, Robert; Hanauer, Stephen B; Colombel, Jean-Frédéric; Panaccione, Remo; D'Haens, Geert; Li, Ju; Rosenfeld, Marie R; Kent, Jeffrey D; Pollack, Paul F
2007-06-19
Adalimumab, a fully human tumor necrosis factor (TNF) antagonist, is an effective treatment for patients with Crohn disease who are naive to the chimeric TNF antagonist, infliximab. No anti-TNF agent has been evaluated prospectively in patients with Crohn disease who had responded to another anti-TNF agent and then lost that response or were intolerant of the agent. To determine whether adalimumab induces remissions more frequently than placebo in adult patients with Crohn disease who have symptoms despite infliximab therapy or who cannot take infliximab because of adverse events. 4-week, randomized, double-blind, placebo-controlled trial (November 2004 to December 2005). 52 sites in the United States, Canada, and Europe. 325 adults 18 to 75 years of age who had a history of Crohn disease for 4 months or more that was moderate to severe at baseline (Crohn's Disease Activity Index [CDAI] score, 220 to 450 points). Patients were randomly assigned to receive induction doses of adalimumab, 160 mg and 80 mg, at weeks 0 and 2, respectively, or placebo at the same time points. The primary end point was induction of remission at week 4. Decreases in CDAI score by 70 or more and 100 or more points (secondary end points) were also measured. A total of 301 patients completed the trial. Twenty-one percent (34 of 159) of patients in the adalimumab group versus 7% (12 of 166) of those in the placebo group achieved remission at week 4 (P < 0.001). The absolute difference in clinical remission rates was 14.2 percentage points (95% CI, 6.7 to 21.6 percentage points). A 70-point response occurred at week 4 in 52% (82 of 159) of patients in the adalimumab group versus 34% (56 of 166) of patients in the placebo group (P = 0.001). The absolute difference in 70-point response rates was 17.8 percentage points (CI, 7.3 to 28.4 percentage points). Two of 159 patients in the adalimumab group and 4 of 166 patients in the placebo group discontinued treatment because of adverse events. No patients in the adalimumab group and 4 of 166 patients in the placebo group had a serious infection. The trial did not directly compare alternative active treatments and did not evaluate maintenance of response or long-term immunogenicity of adalimumab. Adalimumab induces remissions more frequently than placebo in adult patients with Crohn disease who cannot tolerate infliximab or have symptoms despite receiving infliximab therapy. For more information on adalimumab in Crohn disease, click here. ClinicalTrials.gov registration number: NCT00105300.
Ershow, Gennady Moiseevich; Kirillov, Evgenii Vladislavovich; Mirzabekov, Andrei Darievich
1998-01-01
A device for dispensing microdoses of aqueous solutions are provided, whereby the substance is transferred by the free surface end of a rodlike transferring element; the temperature of the transferring element is maintained at essentially the dew point of the ambient air during the transfer. The device may comprise a plate-like base to which are affixed a plurality of rods; the unfixed butt ends of the rods are coplanar. The device further comprises a means for maintaining the temperature of the unfixed butt ends of the rods essentially equal to the dew point of the ambient air during transfer of the aqueous substance.
Wang, Tengxing; Jiang, Wei; Divan, Ralu; ...
2017-08-03
A Permalloy (Py) thin film enabled tunable 3-D solenoid inductor is designed and fabricated. The special configuration of magnetic core is discussed and by selectively patterning Py thin film, the proposed tunable inductor can work at frequency up to several GHz range. The inductance of the solenoid inductor can be electrically tuned by dc current and the tunability is above 10%. Utilizing the implemented Py enabled tunable solenoid inductor and Lead Zirconate Titanate (PZT) thin film enabled metal-insulator-metal (MIM) capacitor, a compact fully electrically tunable lumped elements phase shifter is achieved. The tunable phase shifter has both inductive and capacitivemore » tunability and the dual tunability significantly improves the tuning range and design flexibility. Moreover, the dual tunability is able to retain the equivalent characteristic impedance of the device in the process of the phase being tuned. Here, the phase of the device can be tuned by fully electrical methods and when dc current and dc voltage are provided, the length normalized phase tunability is up to 210°/cm« less
Separation of CHO cells using hydrocyclones.
Pinto, Rodrigo C V; Medronho, Ricardo A; Castilho, Leda R
2008-01-01
Hydrocyclones are simple and robust separation devices with no moving parts. In the past few years, their use in animal cell separation has been proposed. In this work, the use of different hydrocyclone configurations for Chinese hamster ovary (CHO) cell separation was investigated following an experimental design. It was shown that cell separation efficiencies for cultures of the wild-type CHO.K1 cell line and of a recombinant CHO cell line producing granulocyte-macrophage colony stimulating factor (GM-CSF) were kept above 97%. Low viability losses were observed, as measured by trypan blue exclusion and by determination of intracellular lactate dehydrogenase (LDH) released to the culture medium. Mathematical models were proposed to predict the flow rate, flow ratio and separation efficiency as a function of hydrocyclone geometry and pressure drop. When cells were monitored for any induction of apoptosis upon passage through the hydrocyclones, no increase in apoptotic cell concentration was observed within 48 h of hydrocycloning. Thus, based on the high separation efficiencies, the robustness of the equipment, and the absence of apoptosis induction, hydrocyclones seem to be specially suited for use as cell retention devices in long-term perfusion runs.
NASA Astrophysics Data System (ADS)
Matsui, Y.; Watanabe, T.; Satani, T.; Muramatsu, M.; Tanaka, K.; Kitagawa, A.; Yoshida, Y.; Sato, F.; Kato, Y.; Iida, T.
2008-11-01
Multiply charged iron ions are produced from solid pure material in an electron cyclotron resonance (ECR) ion source. We develop an evaporator by using induction heating with the induction coil which is made from bare molybdenum wire and surrounding the pure iron rod. We optimize the shape of induction heating coil and operation of rf power supply. We conduct experiment to investigate reproducibility and stability in the operation and heating efficiency. Induction heating evaporator produces pure material vapor, because materials directly heated by eddy currents have non-contact with insulated materials which are impurity gas sources. The power and the frequency of the induction currents range from 100 to 900 W and from 48 to 23 kHz, respectively. The working pressure is about 10-4 to 10-3 Pa. We measure temperature of iron rod and film deposition rate by depositing iron vapor to crystal oscillator. We confirm stability and reproducibility of evaporator enough to conduct experiment in ECR ion source. We can obtain required temperature of iron under maximum power of power supply. We are aiming the evaporator higher melting point material than iron.
van der Burg, Pauline S; Miedema, Martijn; de Jongh, Frans H; Frerichs, Inez; van Kaam, Anton H
2014-06-01
Electrical impedance tomography measures lung volume in a cross-sectional slice of the lung. Whether these cross-sectional volume changes are representative of the whole lung has only been investigated in adults, showing conflicting results. This study aimed to compare cross-sectional and whole lung volume changes using electrical impedance tomography and respiratory inductive plethysmography. A prospective, single-center, observational, nonrandomized study. The study was conducted in a neonatal ICU in the Netherlands. High-frequency ventilated preterm infants with respiratory distress syndrome. Cross-sectional and whole lung volume changes were continuously and simultaneously measured by, respectively, electrical impedance tomography and respiratory inductive plethysmography during a stepwise recruitment procedure. End-expiratory lung volume changes were assessed by mapping the inflation and deflation limbs using both the pressure/impedance and pressure/inductance pairs and characterized by calculating the inflection points. In addition, oscillatory tidal volume changes were assessed at each pressure step. Twenty-three infants were included in the study. Of these, eight infants had to be excluded because the quality of the registration was insufficient for analysis (two electrical impedance tomography and six respiratory inductive plethysmography). In the remaining 15 infants (gestational age 28.0 ± 2.6 wk; birth weight 1,027 ± 514 g), end-expiratory lung volume changes measured by electrical impedance tomography were significantly correlated to respiratory inductive plethysmography measurements in 12 patients (mean r = 0.93 ± 0.05). This was also true for the upper inflection point on the inflation (r = 0.91, p < 0.01) and deflation limb (r = 0.83, p < 0.01). In 13 patients, impedance and inductance data also correlated significantly on oscillatory tidal volume/pressure relationships (mean r = 0.81 ± 0.18). This study shows that cross-sectional lung volume changes measured by electrical impedance tomography are representative for the whole lung and that this concept also applies to newborn infants.
Lee, Tzu-Hsien
2005-12-01
This study examined the effects of operating a built-in touch-pad pointing device and a trackball mouse on participants' completion times, hand positions during operation, postural angles, and muscle activities. 8 young men were asked to perform a cursor travel task on a notebook computer using both 60- and 80-cm high table conditions. Analysis showed that the trackball mouse significantly decreased completion times. Participants selected a hand position farther from the table edge and larger elbow angle for the trackball mouse than for the built-in touch-pad pointing device. Participants' neck, thoracic, and arm angles, or splenius capitis, trapezius, deltoid, and erector spinae muscle activities were not significantly affected by the devices, but table height significantly affected participants' completion times, hand positions, and postural angles.
Impact of Mobility Device Use on Quality of Life in Children With Friedreich Ataxia.
Ejaz, Resham; Chen, Shiyi; Isaacs, Charles J; Carnevale, Amanda; Wilson, Judith; George, Kristen; Delatycki, Martin B; Perlman, Susan L; Mathews, Katherine D; Wilmot, George R; Hoyle, J Chad; Subramony, Sub H; Zesiewicz, Theresa; Farmer, Jennifer M; Lynch, David R; Yoon, Grace
2018-05-01
To determine how mobility device use impacts quality of life in children with Friedreich ataxia. Data from 111 pediatric patients with genetically confirmed Friedreich ataxia were collected from a prospective natural history study utilizing standardized clinical evaluations, including health-related quality of life using the Pediatric Quality of Life Inventory (PedsQL) 4.0 Generic Core Module. Mobility device use was associated with worse mean PedsQL total, physical, emotional, social, and academic subscores, after adjusting for gender, age of disease onset, and Friedreich Ataxia Rating Scale score. The magnitude of the difference was greatest for the physical subscore (-19.5 points, 95% CI = -30.00, -8.99, P < .001) and least for the emotional subscore (-10.61 points, 95% CI = -20.21, -1.02, P = .03). Transition to or between mobility devices trended toward worse physical subscore (-16.20 points, 95% CI = -32.07, -0.33, P = .05). Mobility device use is associated with significant worsening of all domains of quality of life in children with Friedreich ataxia.
Point-of-care blood eosinophil count in a severe asthma clinic setting.
Heffler, Enrico; Terranova, Giovanni; Chessari, Carlo; Frazzetto, Valentina; Crimi, Claudia; Fichera, Silvia; Picardi, Giuseppe; Nicolosi, Giuliana; Porto, Morena; Intravaia, Rossella; Crimi, Nunzio
2017-07-01
One of the main severe asthma phenotypes is severe eosinophilic or eosinophilic refractory asthma for which novel biologic agents are emerging as therapeutic options. In this context, blood eosinophil counts are one of the most reliable biomarkers. To evaluate the performance of a point-of-care peripheral blood counter in a patients with severe asthma. The blood eosinophil counts of 76 patients with severe asthma were evaluated by point-of-care and standard analyzers. A significant correlation between blood eosinophils assessed by the 2 devices was found (R 2 = 0.854, P < .001); similar correlations were found also for white blood cells, neutrophils, and lymphocytes. The point-of-care device had the ability to predict blood eosinophil cutoffs used to select patients for biologic treatments for severe eosinophilic asthma and the ELEN index, a composite score useful to predict sputum eosinophilia. The results of our study contribute to the validation of a point-of-care device to assess blood eosinophils and open the possibility of using this device for the management of severe asthma management. Copyright © 2017 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
A Figure-of-Merit for Designing High-Performance Inductive Power Transmission Links
Kiani, Mehdi; Ghovanloo, Maysam
2014-01-01
Power transfer efficiency (PTE) and power delivered to the load (PDL) are two key inductive link design parameters that relate to the power source and driver specs, power loss, transmission range, robustness against misalignment, variations in loading, and interference with other devices. Designers need to strike a delicate balance between these two because designing the link to achieve high PTE will degrade the PDL and vice versa. We are proposing a new figure-of-merit (FoM), which can help designers to find out whether a two-, three-, or four-coil link is appropriate for their particular application and guide them through an iterative design procedure to reach optimal coil geometries based on how they weigh the PTE versus PDL for that application. Three design examples at three different power levels have been presented based on the proposed FoM for implantable microelectronic devices, handheld mobile devices, and electric vehicles. The new FoM suggests that the two-coil links are suitable when the coils are strongly coupled, and a large PDL is needed. Three-coil links are the best when the coils are loosely coupled, the coupling distance varies considerably, and large PDL is necessary. Finally, four-coil links are optimal when the PTE is paramount, the coils are loosely coupled, and their relative distance and alignment are stable. Measurement results support the accuracy of the theoretical design procedure and conclusions. PMID:25382898
Discharge start-up and ramp-up development for NSTX-U and MAST-U
NASA Astrophysics Data System (ADS)
Battaglia, D. J.; Boyer, M. D.; Gerhardt, S. P.; Menard, J. E.; Mueller, D.; Cunningham, G.; Kirk, A.; Kogan, L.; McArdle, G.; Pangione, L.; Thornton, A. J.; Ren, E.
2017-10-01
A collaborative modeling effort is underway to develop robust inductive start-up and ramp-up scenarios for NSTX-U and MAST-U. These complementary spherical tokamak devices aim to generate the physics basis for achieving steady-state, high-beta and high-confinement plasma discharges with a self-consistent solution for managing the divertor heat flux. High-performance discharges in these devices require sufficient plasma elongation (κ = 2.4 - 2.8) to maximize the bootstrap and beam-driven current drive, increase MHD stability at high Ip and high βN, and realize advanced divertor geometries such as the snowflake and super-X. Achieving the target elongation on NSTX-U is enabled by an L-H transition in the current ramp-up that slows the current diffusion and maintains a low internal inductance (li <= 0.8). Modeling focuses on developing scenarios that achieve a suitable field null for breakdown and discharge conditions conducive to an early L-H transition while maintaining vertical and MHD stability, with appropriate margin for variation in experimental conditions. The toroidal currents induced in conducting structures and the specifications of the real-time control and power supply systems are unique constraints for the two devices. Work Supported by U.S. DOE Contract No. DE-AC02-09CH11466 and the RCUK Energy Programme [Grant Number EP/P012450/1].
A Figure-of-Merit for Designing High-Performance Inductive Power Transmission Links.
Kiani, Mehdi; Ghovanloo, Maysam
2012-11-16
Power transfer efficiency (PTE) and power delivered to the load (PDL) are two key inductive link design parameters that relate to the power source and driver specs, power loss, transmission range, robustness against misalignment, variations in loading, and interference with other devices. Designers need to strike a delicate balance between these two because designing the link to achieve high PTE will degrade the PDL and vice versa. We are proposing a new figure-of-merit (FoM), which can help designers to find out whether a two-, three-, or four-coil link is appropriate for their particular application and guide them through an iterative design procedure to reach optimal coil geometries based on how they weigh the PTE versus PDL for that application. Three design examples at three different power levels have been presented based on the proposed FoM for implantable microelectronic devices, handheld mobile devices, and electric vehicles. The new FoM suggests that the two-coil links are suitable when the coils are strongly coupled, and a large PDL is needed. Three-coil links are the best when the coils are loosely coupled, the coupling distance varies considerably, and large PDL is necessary. Finally, four-coil links are optimal when the PTE is paramount, the coils are loosely coupled, and their relative distance and alignment are stable. Measurement results support the accuracy of the theoretical design procedure and conclusions.
Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system.
Abiri, Parinaz; Abiri, Ahmad; Packard, René R Sevag; Ding, Yichen; Yousefi, Alireza; Ma, Jianguo; Bersohn, Malcolm; Nguyen, Kim-Lien; Markovic, Dejan; Moloudi, Shervin; Hsiai, Tzung K
2017-07-21
Pacemakers have existed for decades as a means to restore cardiac electrical rhythms. However, lead-related complications have remained a clinical challenge. While market-released leadless devices have addressed some of the issues, their pacer-integrated batteries cause new health risks and functional limitations. Inductive power transfer enables wireless powering of bioelectronic devices; however, Specific Absorption Rate and size limitations reduce power efficiency for biomedical applications. We designed a remote-controlled system in which power requirements were significantly reduced via intermittent power transfer to control stimulation intervals. In parallel, the cardiac component was miniaturized to facilitate intravascular deployment into the anterior cardiac vein. Given size constraints, efficiency was optimal via a circular receiver coil wrapped into a half-cylinder with a meandering tail. The pacemaker was epicardially tested in a euthanized pig at 60 beats per minute, 2 V amplitude, and 1 ms pulse width, restoring mean arterial pressure from 0 to 37 mmHg. Power consumption was 1 mW at a range of > 3 cm with no misalignment and at 2 cm with 45° displacement misalignment, 45° x-axis angular misalignment, or 45° y-axis angular misalignment. Thus, we demonstrated a remote-controlled miniaturized pacing system with low power consumption, thereby providing a basis for the next generation of wireless implantable devices.
40 CFR 141.100 - Criteria and procedures for public water systems using point-of-entry devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... water systems using point-of-entry devices. 141.100 Section 141.100 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER... meet all national primary drinking water regulations and would be of acceptable quality similar to...
Multi-beam and single-chip LIDAR with discrete beam steering by digital micromirror device
NASA Astrophysics Data System (ADS)
Rodriguez, Joshua; Smith, Braden; Hellman, Brandon; Gin, Adley; Espinoza, Alonzo; Takashima, Yuzuru
2018-02-01
A novel Digital Micromirror Device (DMD) based beam steering enables a single chip Light Detection and Ranging (LIDAR) system for discrete scanning points. We present increasing number of scanning point by using multiple laser diodes for Multi-beam and Single-chip DMD-based LIDAR.
Optical projectors simulate human eyes to establish operator's field of view
NASA Technical Reports Server (NTRS)
Beam, R. A.
1966-01-01
Device projects visual pattern limits of the field of view of an operator as his eyes are directed at a given point on a control panel. The device, which consists of two projectors, provides instant evaluation of visual ability at a point on a panel.
Dennerlein, J T; Yang, M C
2001-01-01
Pointing devices, essential input tools for the graphical user interface (GUI) of desktop computers, require precise motor control and dexterity to use. Haptic force-feedback devices provide the human operator with tactile cues, adding the sense of touch to existing visual and auditory interfaces. However, the performance enhancements, comfort, and possible musculoskeletal loading of using a force-feedback device in an office environment are unknown. Hypothesizing that the time to perform a task and the self-reported pain and discomfort of the task improve with the addition of force feedback, 26 people ranging in age from 22 to 44 years performed a point-and-click task 540 times with and without an attractive force field surrounding the desired target. The point-and-click movements were approximately 25% faster with the addition of force feedback (paired t-tests, p < 0.001). Perceived user discomfort and pain, as measured through a questionnaire, were also smaller with the addition of force feedback (p < 0.001). However, this difference decreased as additional distracting force fields were added to the task environment, simulating a more realistic work situation. These results suggest that for a given task, use of a force-feedback device improves performance, and potentially reduces musculoskeletal loading during mouse use. Actual or potential applications of this research include human-computer interface design, specifically that of the pointing device extensively used for the graphical user interface.
Point-of-Care Diagnostics for Niche Applications
Cummins, Brian M.; Ligler, Frances S.; Walker, Glenn M.
2016-01-01
Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. PMID:26837054
NASA Astrophysics Data System (ADS)
Kato, Y.; Takenaka, T.; Yano, K.; Kiriyama, R.; Kurisu, Y.; Nozaki, D.; Muramatsu, M.; Kitagawa, A.; Uchida, T.; Yoshida, Y.; Sato, F.; Iida, T.
2012-11-01
Multiply charged ions to be used prospectively are produced from solid pure material in an electron cyclotron resonance ion source (ECRIS). Recently a pure iron source is also required for the production of caged iron ions in the fullerene in order to control cells in vivo in bio-nano science and technology. We adopt directly heating iron rod by induction heating (IH) because it has non-contact with insulated materials which are impurity gas sources. We choose molybdenum wire for the IH coils because it doesn't need water cooling. To improve power efficiency and temperature control, we propose to the new circuit without previously using the serial and parallel dummy coils (SPD) for matching and safety. We made the circuit consisted of inductively coupled coils which are thin-flat and helix shape, and which insulates the IH power source from the evaporator. This coupling coils circuit, i.e. insulated induction heating coil transformer (IHCT), can be move mechanically. The secondary current can be adjusted precisely and continuously. Heating efficiency by using the IHCT is much higher than those of previous experiments by using the SPD, because leakage flux is decreased and matching is improved simultaneously. We are able to adjust the temperature in heating the vapor source around melting point. And then the vapor pressure can be controlled precisely by using the IHCT. We can control ±10K around 1500°C by this method, and also recognize to controlling iron vapor flux experimentally in the extreme low pressures. Now we come into next stage of developing induction heating vapor source for materials with furthermore high temperature melting points above 2000K with the IHCT, and then apply it in our ECRIS.
Wetmore, Douglas; Goldberg, Andrew; Gandhi, Nishant; Spivack, John; McCormick, Patrick; DeMaria, Samuel
2016-10-01
Anaesthesiologists work in a high stress, high consequence environment in which missed steps in preparation may lead to medical errors and potential patient harm. The pre-anaesthetic induction period has been identified as a time in which medical errors can occur. The Anesthesia Patient Safety Foundation has developed a Pre-Anesthetic Induction Patient Safety (PIPS) checklist. We conducted this study to test the effectiveness of this checklist, when embedded in our institutional Anesthesia Information Management System (AIMS), on resident performance in a simulated environment. Using a randomised, controlled, observer-blinded design, we compared performance of anaesthesiology residents in a simulated operating room under production pressure using a checklist in completing a thorough pre-anaesthetic induction evaluation and setup with that of residents with no checklist. The checklist was embedded in the simulated operating room's electronic medical record. Data for 38 anaesthesiology residents shows a statistically significant difference in performance in pre-anaesthetic setup and evaluation as scored by blinded raters (maximum score 22 points), with the checklist group performing better by 7.8 points (p<0.01). The effects of gender and year of residency on total score were not significant. Simulation duration (time to anaesthetic agent administration) was increased significantly by the use of the checklist. Required use of a pre-induction checklist improves anaesthesiology resident performance in a simulated environment. The PIPS checklist as an integrated part of a departmental AIMS warrant further investigation as a quality measure. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Development path and current status of the NANIVID: a new device for cancer cell studies.
Raja, Waseem Khan; Padgen, Michael R; Williams, James K; Gertler, Frank B; Wyckoff, Jeffrey B; Condeelis, John S; Castracane, James
2012-03-29
Cancer cells create a unique microenvironment in vivo that enables migration to distant organs. To better understand the tumor micro-environment, special tools and devices are required to monitor the interactions between different cell types and the effects of particular chemical gradients. Our study presents the design and optimization of a versatile chemotaxis device, the nano-intravital device (NANIVID), which consists of etched and bonded glass substrates that create a soluble factor reservoir. The device contains a customized hydrogel blend that is loaded with epidermal growth factor (EGF), which diffuses from the outlet to create a chemotactic gradient that can be sustained for many hours in order to attract specific cells to the device. A microelectrode array is under development for quantification of cell collection and will be incorporated into future device generations. Additionally, the NANIVID can be modified to generate gradients of other soluble factors in order to initiate controlled changes to the microenvironment including the induction of hypoxia, manipulation of extracellular matrix stiffness, etc. The focus of the article is to present the design and optimization of the device towards wide ranging applications of cancer cell dynamics in vitro and, ultimately, implantation for in vivo investigations.
Wireless microsensor network solutions for neurological implantable devices
NASA Astrophysics Data System (ADS)
Abraham, Jose K.; Whitchurch, Ashwin; Varadan, Vijay K.
2005-05-01
The design and development of wireless mocrosensor network systems for the treatment of many degenerative as well as traumatic neurological disorders is presented in this paper. Due to the advances in micro and nano sensors and wireless systems, the biomedical sensors have the potential to revolutionize many areas in healthcare systems. The integration of nanodevices with neurons that are in communication with smart microsensor systems has great potential in the treatment of many neurodegenerative brain disorders. It is well established that patients suffering from either Parkinson"s disease (PD) or Epilepsy have benefited from the advantages of implantable devices in the neural pathways of the brain to alter the undesired signals thus restoring proper function. In addition, implantable devices have successfully blocked pain signals and controlled various pelvic muscles in patients with urinary and fecal incontinence. Even though the existing technology has made a tremendous impact on controlling the deleterious effects of disease, it is still in its infancy. This paper presents solutions of many problems of today's implantable and neural-electronic interface devices by combining nanowires and microelectronics with BioMEMS and applying them at cellular level for the development of a total wireless feedback control system. The only device that will actually be implanted in this research is the electrodes. All necessary controllers will be housed in accessories that are outside the body that communicate with the implanted electrodes through tiny inductively-coupled antennas. A Parkinson disease patient can just wear a hat-system close to the implantable neural probe so that the patient is free to move around, while the sensors continually monitor, record, transmit all vital information to health care specialist. In the event of a problem, the system provides an early warning to the patient while they are still mobile thus providing them the opportunity to react and trigger the feed back system or contact a point-of-care office that can remotely control the implantable system. The remote monitoring technology can be adaptable to EEG monitoring of children with epilepsy, implantable cardioverters/defibrillators, pacemakers, chronic pain management systems, treatment for sleep disorders, patients with implantable devices for diabetes. In addition, the development of a wireless neural electronics interface to detect, transmit and analyze neural signals could help patients with spinal injuries to regain some semblance of mobile activity.
Tomich, Georgia Miranda; França, Danielle Corrêa; Diniz, Marco Túlio Costa; Britto, Raquel Rodrigues; Sampaio, Rosana Ferreira; Parreira, Verônica Franco
2010-01-01
To evaluate breathing pattern and thoracoabdominal motion during breathing exercises. Twenty-four patients with class II or III obesity (18 women; 6 men) were studied on the second postoperative day after gastroplasty. The mean age was 37 +/- 11 years, and the mean BMI was 44 +/- 3 kg/m(2). Diaphragmatic breathing, incentive spirometry with a flow-oriented device and incentive spirometry with a volume-oriented device were performed in random order. Respiratory inductive plethysmography was used in order to measure respiratory variables and thoracoabdominal motion. Comparisons among the three exercises showed significant differences: tidal volume was higher during incentive spirometry (with the flow-oriented device or with the volume-oriented device) than during diaphragmatic breathing; the respiratory rate was lower during incentive spirometry with the volume-oriented device than during incentive spirometry with the flow-oriented device; and minute ventilation was higher during incentive spirometry (with the flow-oriented device or with the volume-oriented device) than during diaphragmatic breathing. Rib cage motion did not vary during breathing exercises, although there was an increase in thoracoabdominal asynchrony, especially during incentive spirometry with the flow-oriented device. Among the breathing exercises evaluated, incentive spirometry with the volume-oriented device provided the best results, because it allowed slower, deeper inhalation.
High-Precision Hysteresis Sensing of the Quartz Crystal Inductance-to-Frequency Converter
Matko, Vojko; Milanović, Miro
2016-01-01
A new method for the automated measurement of the hysteresis of the temperature-compensated inductance-to-frequency converter with a single quartz crystal is proposed. The new idea behind this method is a converter with two programmable analog switches enabling the automated measurement of the converter hysteresis, as well as the temperature compensation of the quartz crystal and any other circuit element. Also used is the programmable timing control device that allows the selection of different oscillating frequencies. In the proposed programmable method two different inductances connected in series to the quartz crystal are switched in a short time sequence, compensating the crystal’s natural temperature characteristics (in the temperature range between 0 and 50 °C). The procedure allows for the measurement of the converter hysteresis at various values of capacitance connected in parallel with the quartz crystal for the converter sensitivity setting at selected inductance. It, furthermore, enables the measurement of hysteresis at various values of inductance at selected parallel capacitance (sensitivity) connected to the quartz crystal. The article shows that the proposed hysteresis measurement of the converter, which converts the inductance in the range between 95 and 100 μH to a frequency in the range between 1 and 200 kHz, has only 7 × 10−13 frequency instability (during the temperature change between 0 and 50 °C) with a maximum 1 × 10−11 hysteresis frequency difference. PMID:27367688
Impact of Lateral Straggle on the Analog/RF Performance of Asymmetric Gate Stack Double Gate MOSFET
NASA Astrophysics Data System (ADS)
Sivaram, Gollamudi Sai; Chakraborty, Shramana; Das, Rahul; Dasgupta, Arpan; Kundu, Atanu; Sarkar, Chandan K.
2016-09-01
This paper presents a systematic comparative study of Analog and RF performances of an underlapped double gate (U-DG) NMOSFET with Gate Stack (GS) for varying straggle lengths. Asymmetric underlap devices (A-U-DG) have been proposed as one of the remedies for reducing Short Channel Effects (SCE's) with the underlap being present towards the source for sub 20 nm devices. However, the Source to Drain (S/D) implant lateral diffusion leads to a variation in the effective underlap length. This paper investigates the impact of variation of straggle length on the Analog and RF parameters of the device. The RF performance is analyzed by considering the intrinsic capacitances (Cgd, Cgs), intrinsic resistances (Rgd, Rgs), transport delay (τm), inductance (Lsd), cutoff frequency (fT), and the maximum frequency of oscillations (fmax). The circuit performance of the devices are also studied. It is seen that the Analog and RF performances of the devices are improved by optimizing the S/D lateral straggle.
NIMROD Modeling of HIT-SI and HIT-SI3
NASA Astrophysics Data System (ADS)
Morgan, Kyle; Jarboe, Tom; Hossack, Aaron
2016-10-01
The HIT-SI and HIT-SI3 devices are spheromaks formed and sustained via a set of Steady Inductive Helicity Injectors (SIHI) that are operated in AC. The experiment explores the formation and sustain of stable spheromaks with a variety of perturbation mode structures. The HIT-SI device consisted of two injectors with primarily n = 1 toroidal symmetry while the HIT-SI3 device has three injectors capable of a mixture of n = 1 and n = 2 perturbations or a primarily n = 3 perturbation, depending on the relative phase of the injectors. Using the NIMROD code to model these devices, we are able to validate with experimental results (previously only done on HIT-SI) and examine the interaction between the injectors and the spheromak. Simulations are performed with both finite and zero- β models to gain an understanding of the thermal properties of the device. Additionally, a set of extrapolation simulations has been performed illustrating the spontaneous formation of closed flux surfaces at high current amplification. Work supported by the US DOE.
High reliability linear drive device for artificial hearts
NASA Astrophysics Data System (ADS)
Ji, Jinghua; Zhao, Wenxiang; Liu, Guohai; Shen, Yue; Wang, Fangqun
2012-04-01
In this paper, a new high reliability linear drive device, termed as stator-permanent-magnet tubular oscillating actuator (SPM-TOA), is proposed for artificial hearts (AHs). The key is to incorporate the concept of two independent phases into this linear AH device, hence achieving high reliability operation. The fault-tolerant teeth are employed to provide the desired decoupling phases in magnetic circuit. Also, as the magnets and the coils are located in the stator, the proposed SPM-TOA takes the definite advantages of robust mover and direct-drive capability. By using the time-stepping finite element method, the electromagnetic characteristics of the proposed SPM-TOA are analyzed, including magnetic field distributions, flux linkages, back- electromotive forces (back-EMFs) self- and mutual inductances, as well as cogging and thrust forces. The results confirm that the proposed SPM-TOA meets the dimension, weight, and force requirements of the AH drive device.
Simulation analysis on miniature wireless power transfer system
NASA Astrophysics Data System (ADS)
Liu, Tao; Wei, Zhiqiang; Yin, Bo; Chi, Haokun; Du, Panpan
2018-03-01
In recent years, the research on implantable medical devices has become a hot scientific topic, and the power supply of these devices are especially concerned. Generally, these devices are usually powered by disposable batteries. However, for some of the long-term human implant devices, such as pacemakers, once the battery has been exhausted after several years, the patient has to replace the battery by surgery, which increases the patient’s economic burden and pain. Wireless power transfer technology, using non-contact way for power transfer, can be a good solution to this problem. In this paper, a micro induction coil was designed, and the transfer efficiency in the air and human tissue model of two-layers were simulated by Ansoft HFSS. The results showed that the system could achieve the energy transfer in both cases, meanwhile, it indicated that the transfer efficiency was lower in a relative larger permittivity of transmission medium.
Modelling switching-time effects in high-frequency power conditioning networks
NASA Technical Reports Server (NTRS)
Owen, H. A.; Sloane, T. H.; Rimer, B. H.; Wilson, T. G.
1979-01-01
Power transistor networks which switch large currents in highly inductive environments are beginning to find application in the hundred kilohertz switching frequency range. Recent developments in the fabrication of metal-oxide-semiconductor field-effect transistors in the power device category have enhanced the movement toward higher switching frequencies. Models for switching devices and of the circuits in which they are imbedded are required to properly characterize the mechanisms responsible for turning on and turning off effects. Easily interpreted results in the form of oscilloscope-like plots assist in understanding the effects of parametric studies using topology oriented computer-aided analysis methods.
Heating and current drive on NSTX
NASA Astrophysics Data System (ADS)
Wilson, J. R.; Batchelor, D.; Carter, M.; Hosea, J.; Ignat, D.; LeBlanc, B.; Majeski, R.; Ono, M.; Phillips, C. K.; Rogers, J. H.; Schilling, G.
1997-04-01
Low aspect ratio tokamaks pose interesting new challenges for heating and current drive. The NSTX (National Spherical Tokamak Experiment) device to be built at Princeton is a low aspect ratio toroidal device that has the achievement of high toroidal beta (˜45%) and non-inductive operation as two of its main research goals. To achieve these goals significant auxiliary heating and current drive systems are required. Present plans include ECH (Electron cyclotron heating) for pre-ionization and start-up assist, HHFW (high harmonic fast wave) for heating and current drive and eventually NBI (neutral beam injection) for heating, current drive and plasma rotation.
NASA Astrophysics Data System (ADS)
Grasland-Mongrain, Pol; Miller-Jolicoeur, Erika; Tang, An; Catheline, Stefan; Cloutier, Guy
2016-03-01
This study presents the first observation of shear waves induced remotely within soft tissues. It was performed through the combination of a transcranial magnetic stimulation device and a permanent magnet. A physical model based on Maxwell and Navier equations was developed. Experiments were performed on a cryogel phantom and a chicken breast sample. Using an ultrafast ultrasound scanner, shear waves of respective amplitudes of 5 and 0.5 μm were observed. Experimental and numerical results were in good agreement. This study constitutes the framework of an alternative shear wave elastography method.
21 CFR 870.2640 - Portable leakage current alarm.
Code of Federal Regulations, 2014 CFR
2014-04-01
... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if...
21 CFR 870.2640 - Portable leakage current alarm.
Code of Federal Regulations, 2013 CFR
2013-04-01
... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if...
21 CFR 870.2640 - Portable leakage current alarm.
Code of Federal Regulations, 2012 CFR
2012-04-01
... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if...
Induction of antigen-specific immunity by pH-sensitive carbonate apatite as a potent vaccine carrier
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hebishima, Takehisa; Tada, Seiichi; Takeshima, Shin-nosuke
Highlights: Black-Right-Pointing-Pointer To develop effective vaccine, we examined the effects of CO{sub 3}Ap as an antigen carrier. Black-Right-Pointing-Pointer OVA contained in CO{sub 3}Ap was taken up by BMDCs more effectively than free OVA. Black-Right-Pointing-Pointer OVA-immunized splenocytes was activated by OVA contained in CO{sub 3}Ap effectively. Black-Right-Pointing-Pointer OVA contained in CO{sub 3}Ap induced strong OVA-specific immune responses to C57BL/6 mice. Black-Right-Pointing-Pointer CO{sub 3}Ap is promising antigen carrier for the achievement of effective vaccine. -- Abstract: The ability of carbonate apatite (CO{sub 3}Ap) to enhance antigen-specific immunity was examined in vitro and in vivo to investigate its utility as a vaccine carrier.more » Murine bone marrow-derived dendritic cells took up ovalbumin (OVA) containing CO{sub 3}Ap more effectively than free OVA. Interestingly, mice immunized with OVA-containing CO{sub 3}Ap produced OVA-specific antibodies more effectively than mice immunized with free OVA. Furthermore, immunization of C57BL/6 mice with OVA-containing CO{sub 3}Ap induced the proliferation and antigen-specific production of IFN-{gamma} by splenocytes more strongly than immunization with free OVA. Moreover, no significant differences were detected in the induction of delayed-type hypersensitivity responses, an immune reaction involving an antigen-specific, cell-mediated immune response between OVA-containing CO{sub 3}Ap and OVA-containing alumina salt (Alum), suggesting that CO{sub 3}Ap induced cell-mediated immune response to the same degree as Alum, which is commonly used for clinical applications. This study is the first to demonstrate the induction of antigen-specific immune responses in vivo by CO{sub 3}Ap.« less
Development of a Hard X-ray Beam Position Monitor for Insertion Device Beams at the APS
NASA Astrophysics Data System (ADS)
Decker, Glenn; Rosenbaum, Gerd; Singh, Om
2006-11-01
Long-term pointing stability requirements at the Advanced Photon Source (APS) are very stringent, at the level of 500 nanoradians peak-to-peak or better over a one-week time frame. Conventional rf beam position monitors (BPMs) close to the insertion device source points are incapable of assuring this level of stability, owing to mechanical, thermal, and electronic stability limitations. Insertion device gap-dependent systematic errors associated with the present ultraviolet photon beam position monitors similarly limit their ability to control long-term pointing stability. We report on the development of a new BPM design sensitive only to hard x-rays. Early experimental results will be presented.
MAGNETIC METHOD FOR PRODUCING HIGH VELOCITY SHOCK WAVES IN GASES
Josephson, V.
1960-01-26
A device is described for producing high-energy plasmas comprising a tapered shock tube of dielectric material and having a closed small end, an exceedingly low-inductance coll supported about and axially aligned with the small end of the tapered tube. an elongated multiturn coil supported upon the remninder of the exterior wall of the shock tube. a potential source and switch connected in series with the low-inductance coil, a potential source and switch connected in series with the elongated coil, means for hermetically sealing the large end of the tube, means for purging the tube of gases, and means for admitting a selected gas into the shock tube.
NASA Astrophysics Data System (ADS)
Park, Ji-Hwan; Oh, Seung-Ju; Lee, Hyo-Chang; Kim, Yu-Sin; Kim, Young-Cheol; Kim, June Young; Ha, Chang-Seoung; Kwon, Soon-Ho; Lee, Jung-Joong; Chung, Chin-Wook
2014-10-01
As the critical dimension of the nano-device shrinks, an undesired etch profile occurs during plasma etch process. One of the reasons is the local electric field due to the surface charge accumulation. To demonstrate the surface charge accumulation, an anodic aluminum oxide (AAO) membrane which has high aspect ratio is used. The potential difference between top electrode and bottom electrode in an anodic aluminum oxide contact structure is measured during inductively coupled plasma exposure. The voltage difference is changed with external discharge conditions, such as gas pressure, input power, and gas species and the result is analyzed with the measured plasma parameters.
Highly Deformable Liquid Embedded Soft-Matter Capacitors and Inductors for Stretchable Electronics
NASA Astrophysics Data System (ADS)
Fassler, Andrew; Majidi, Carmel
2013-03-01
We have developed a family of soft-matter capacitors and inductors that can be stretched to several times their natural length. These circuit elements are composed of microchannels of a liquid-phase Gallium-Indium-Tin alloy (Galinstan) embedded in a soft silicone elastomer (Ecoflex® 00-30). As the elastomer stretches, the embedded liquid channels deform, causing the capacitance and inductance to change monotonically. The relative changes in capacitance and inductance are experimentally measured as a function of stretch in three directions. The relationships found show potential for these devices to be used as strain sensors and tunable electronic filters. Additionally, theoretical predictions derived using finite elasticity kinematics are consistent with these experimentally found relationships.
Characterization and snubbing of a bidirectional MCT in a resonant ac link converter
NASA Technical Reports Server (NTRS)
Lee, Tony; Elbuluk, Malik E.; Zinger, Donald S.
1993-01-01
The MOS-Controlled Thyristor (MCT) is emerging as a powerful switch that combines the better characteristics of existing power devices. A study of switching stresses on an MCT switch under zero voltage resonant switching is presented. The MCT is used as a bidirectional switch in an ac/ac pulse density modulated inverter for induction motor drive. Current and voltage spikes are observed and analyzed with variations in the timing of the switching. Different snubber circuit configurations are under investigation to minimize the effect of these transients. The results will be extended to study and test the MCT switching in a medium power (5 hp) induction motor drive.
Arrays of membrane isolated yttrium-barium-copper-oxide kinetic inductance bolometers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lindeman, M. A., E-mail: mark.a.lindeman@jpl.nasa.gov; Bonetti, J. A.; Bumble, B.
We are developing of arrays of membrane isolated resonator-bolometers, each with a kinetic inductance device (KID) to measure the temperature of the membrane. The KIDs are fabricated out of the high temperature superconductor YBCO to allow operation at relatively high temperatures. The bolometers are designed to offer higher sensitivity than sensors operating at 300 K, but they require less expensive and lighter weight cooling than even more sensitive conventional superconducting detectors operating at lower temperatures. The bolometer arrays are applicable as focal planes in infrared imaging spectrometers, such as for planetary science missions or earth observing satellites. We describe the devicesmore » and present measurements of their sensitivity.« less
NASA Astrophysics Data System (ADS)
Urade, Yoshiro; Nakata, Yosuke; Okimura, Kunio; Nakanishi, Toshihiro; Miyamaru, Fumiaki; Takeda, Mitsuo W.; Kitano, Masao
2016-03-01
This paper proposes a reconfigurable planar metamaterial that can be switched between capacitive and inductive responses using local changes in the electrical conductivity of its constituent material. The proposed device is based on Babinet's principle and exploits the singular electromagnetic responses of metallic checkerboard structures, which are dependent on the local electrical conductivity. Utilizing the heating-induced metal-insulator transition of vanadium dioxide ($\\mathrm{VO}_2$), the proposed metamaterial is designed to compensate for the effect of the substrate and is experimentally characterized in the terahertz regime. This reconfigurable metamaterial can be utilized as a switchable filter and as a switchable phase shifter for terahertz waves.
Urade, Yoshiro; Nakata, Yosuke; Okimura, Kunio; Nakanishi, Toshihiro; Miyamaru, Fumiaki; Takeda, Mitsuo W; Kitano, Masao
2016-03-07
This paper proposes a reconfigurable planar metamaterial that can be switched between capacitive and inductive responses using local changes in the electrical conductivity of its constituent material. The proposed device is based on Babinet's principle and exploits the singular electromagnetic responses of metallic checkerboard structures, which are dependent on the local electrical conductivity. Utilizing the heating-induced metal-insulator transition of vanadium dioxide (VO 2 ), the proposed meta-material is designed to compensate for the effect of the substrate and is experimentally characterized in the terahertz regime. This reconfigurable metamaterial can be utilized as a switchable filter and as a switchable phase shifter for terahertz waves.
NASA Astrophysics Data System (ADS)
Boulicaut, Jean-Francois; Jeudy, Baptiste
Knowledge Discovery in Databases (KDD) is a complex interactive process. The promising theoretical framework of inductive databases considers this is essentially a querying process. It is enabled by a query language which can deal either with raw data or patterns which hold in the data. Mining patterns turns to be the so-called inductive query evaluation process for which constraint-based Data Mining techniques have to be designed. An inductive query specifies declaratively the desired constraints and algorithms are used to compute the patterns satisfying the constraints in the data. We survey important results of this active research domain. This chapter emphasizes a real breakthrough for hard problems concerning local pattern mining under various constraints and it points out the current directions of research as well.
Experiments and Demonstrations in Physics: Bar-Ilan Physics Laboratory (2nd Edition)
NASA Astrophysics Data System (ADS)
Kraftmakher, Yaakov
2014-08-01
The following sections are included: * Data-acquisition systems from PASCO * ScienceWorkshop 750 Interface and DataStudio software * 850 Universal Interface and Capstone software * Mass on spring * Torsional pendulum * Hooke's law * Characteristics of DC source * Digital storage oscilloscope * Charging and discharging a capacitor * Charge and energy stored in a capacitor * Speed of sound in air * Lissajous patterns * I-V characteristics * Light bulb * Short time intervals * Temperature measurements * Oersted's great discovery * Magnetic field measurements * Magnetic force * Magnetic braking * Curie's point I * Electric power in AC circuits * Faraday's law of induction I * Self-inductance and mutual inductance * Electromagnetic screening * LCR circuit I * Coupled LCR circuits * Probability functions * Photometric laws * Kirchhoff's rule for thermal radiation * Malus' law * Infrared radiation * Irradiance and illuminance
Fuzzy Logic Controlled Solar Module for Driving Three- Phase Induction Motor
NASA Astrophysics Data System (ADS)
Afiqah Zainal, Nurul; Sooi Tat, Chan; Ajisman
2016-02-01
Renewable energy produced by solar module gives advantages for generated three- phase induction motor in remote area. But, solar module's ou tput is uncertain and complex. Fuzzy logic controller is one of controllers that can handle non-linear system and maximum power of solar module. Fuzzy logic controller used for Maximum Power Point Tracking (MPPT) technique to control Pulse-Width Modulation (PWM) for switching power electronics circuit. DC-DC boost converter used to boost up photovoltaic voltage to desired output and supply voltage source inverter which controlled by three-phase PWM generated by microcontroller. IGBT switched Voltage source inverter (VSI) produced alternating current (AC) voltage from direct current (DC) source to control speed of three-phase induction motor from boost converter output. Results showed that, the output power of solar module is optimized and controlled by using fuzzy logic controller. Besides that, the three-phase induction motor can be drive and control using VSI switching by the PWM signal generated by the fuzzy logic controller. This concluded that the non-linear system can be controlled and used in driving three-phase induction motor.
NASA Astrophysics Data System (ADS)
Hoyos Velasco, Fredy Edimer; García, Nicolás Toro; Garcés Gómez, Yeison Alberto
In this paper, the output voltage of a buck power converter is controlled by means of a quasi-sliding scheme. The Fixed Point Inducting Control (FPIC) technique is used for the control design, based on the Zero Average Dynamics (ZAD) strategy, including load estimation by means of the Least Mean Squares (LMS) method. The control scheme is tested in a Rapid Control Prototyping (RCP) system based on Digital Signal Processing (DSP) for dSPACE platform. The closed loop system shows adequate performance. The experimental and simulation results match. The main contribution of this paper is to introduce the load estimator by means of LMS, to make ZAD and FPIC control feasible in load variation conditions. In addition, comparison results for controlled buck converter with SMC, PID and ZAD-FPIC control techniques are shown.
NASA Astrophysics Data System (ADS)
Wei, Yajun; Zhai, Zhaohui; Gunnarsson, Klas; Svedlindh, Peter
2014-11-01
Basic concepts concerning magnetic hysteresis are of vital importance in understanding magnetic materials. However, these concepts are often misinterpreted by many students and even textbooks. We summarize the most common misconceptions and present a new approach to help clarify these misconceptions and enhance students’ understanding of the hysteresis loop. In this approach, students are required to perform an experiment and plot the measured magnetization values and thereby calculated demagnetizing field, internal field, and magnetic induction as functions of the applied field point by point on the same graph. The concepts of the various coercivity, remanence, saturation magnetization, and saturation induction will not be introduced until this stage. By plotting this graph, students are able to interlink all the preceding concepts and intuitively visualize the underlying physical relations between them.
Diversionary device history and revolutionary advancements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cooper, Paul W.; Grubelich, Mark Charles
Diversionary devices also known as flash bangs or stun grenades were first employed about three decades ago. These devices produce a loud bang accompanied by a brilliant flash of light and are employed to temporarily distract or disorient an adversary by overwhelming their visual and auditory senses in order to gain a tactical advantage. Early devices that where employed had numerous shortcomings. Over time, many of these deficiencies were identified and corrected. This evolutionary process led to today's modern diversionary devices. These present-day conventional diversionary devices have undergone evolutionary changes but operate in the same manner as their predecessors. Inmore » order to produce the loud bang and brilliant flash of light, a flash powder mixture, usually a combination of potassium perchlorate and aluminum powder is ignited to produce an explosion. In essence these diversionary devices are small pyrotechnic bombs that produce a high point-source pressure in order to achieve the desired far-field effect. This high point-source pressure can make these devices a hazard to the operator, adversaries and hostages even though they are intended for 'less than lethal' roles. A revolutionary diversionary device has been developed that eliminates this high point-source pressure problem and eliminates the need for the hazardous pyrotechnic flash powder composition. This new diversionary device employs a fuel charge that is expelled and ignited in the atmosphere. This process is similar to a fuel air or thermobaric explosion, except that it is a deflagration, not a detonation, thereby reducing the overpressure hazard. This technology reduces the hazard associated with diversionary devices to all involved with their manufacture, transport and use. An overview of the history of diversionary device development and developments at Sandia National Laboratories will be presented.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-09
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-892] Certain Point-to-Point Network... sale within the United States after importation of certain point-to- point network communication... sale within the United States after importation of certain point-to- point network communication...
NASA Astrophysics Data System (ADS)
Chen, Chun-Yen; Chen, Wei-Cheng; Chang, Ching-Hong; Lee, Yu-Lin; Liu, Wen-Chau
2018-05-01
Textured-sidewall GaN-based light-emitting diodes (LEDs) with various sidewall angles (15-90°) and convex or concave sidewalls prepared using an inductively-coupled-plasma approach are comprehensively fabricated and studied. The device with 45° sidewalls (Device F) and that with convex sidewalls (Device B) show significant improvements in optical properties. Experiments show that, at an injection current of 350 mA, the light output power, external quantum efficiency, wall-plug efficiency, and luminous flux of Device F (Device B) are greatly improved by 18.3% (18.2%), 18.2% (18.2%), 17.3% (19.8%), and 16.6% (18.4%), respectively, compared to those of a conventional LED with flat sidewalls. In addition, negligible degradation in electrical properties is found. The enhanced optical performance is mainly attributed to increased light extraction in the horizontal direction due to a significant reduction in total internal reflection at the textured sidewalls. Therefore, the reported specific textured-sidewall structures (Devices B and F) are promising for high-power GaN-based LED applications.
Screen Channel Liquid Acquisition Devices for Cryogenic Propellants
NASA Technical Reports Server (NTRS)
Chato, David J.; Kudlac, Maureen T.
2005-01-01
This paper describes an on-going project to study the application screen channel liquid acquisition devices to cryogenic propellant systems. The literature of screen liquid acquisition devices is reviewed for prior cryogenic experience. Test programs and apparatus are presented to study these devices. Preliminary results are shown demonstrating bubble points for 200 x 1400 wires per inch and 325 x 2300 wires per inch Dutch twill screens. The 200 x 1400 screen has a bubble point of 15.8 inches of water in isopropyl alcohol and 6.6 inches of water in liquid nitrogen. The 325 x 2300 screen has a bubble point of 24.5 inches of water in isopropyl alcohol, 10.7 inches of water in liquid nitrogen, and 1.83 inches of water in liquid hydrogen. These values are found to be in good agreement with the results reported in the literature.
Pointing Device Performance in Steering Tasks.
Senanayake, Ransalu; Goonetilleke, Ravindra S
2016-06-01
Use of touch-screen-based interactions is growing rapidly. Hence, knowing the maneuvering efficacy of touch screens relative to other pointing devices is of great importance in the context of graphical user interfaces. Movement time, accuracy, and user preferences of four pointing device settings were evaluated on a computer with 14 participants aged 20.1 ± 3.13 years. It was found that, depending on the difficulty of the task, the optimal settings differ for ballistic and visual control tasks. With a touch screen, resting the arm increased movement time for steering tasks. When both performance and comfort are considered, whether to use a mouse or a touch screen for person-computer interaction depends on the steering difficulty. Hence, a input device should be chosen based on the application, and should be optimized to match the graphical user interface. © The Author(s) 2016.
Ultra low-cost, portable smartphone optosensors for mobile point-of-care diagnostics
NASA Astrophysics Data System (ADS)
Wang, Li-Ju; Chang, Yu-Chung; Sun, Rongrong; Li, Lei
2018-02-01
Smartphone optosensors with integrated optical components make mobile point-of-care (MPoC) diagnostics be done near patients' side. It'll especially have a significant impact on healthcare delivery in rural or remote areas. Current FDA-approved PoC devices achieving clinical level are still at high cost and not affordable in rural hospitals. We present a series of ultra low-cost smartphone optical sensing devices for mobile point-of-care diagnosis. Aiming different targeting analytes and sensing mechanisms, we developed custom required optical components for each smartphone optosensros. These optical devices include spectrum readers, colorimetric readers for microplate, lateral flow device readers, and chemiluminescence readers. By integrating our unique designed optical components into smartphone optosening platform, the anlaytes can be precisely detected. Clinical testing results show the clinical usability of our smartphone optosensors. Ultra low-cost portable smartphone optosensors are affordable for rural/remote doctors.
Berghmans, Johan; Weber, Frank; van Akoleyen, Candyce; Utens, Elisabeth; Adriaenssens, Peter; Klein, Jan; Himpe, Dirk
2012-04-01
Parents accompanying their child during induction of anesthesia experience stress. The impact of audiovisual aid (AVA) on parental state anxiety and assessment of the child's anxiety at induction have been studied previously but need closer scrutiny. One hundred and twenty parents whose children were scheduled for day-care surgery entered this randomized, controlled study. The intervention group (n = 60) was exposed to an AVA in the holding area. Parental anxiety was measured with the Spielberger State-Trait Anxiety Inventory and the Amsterdam Preoperative Anxiety and Information Scale (APAIS) at three time points: (i) on admission [T1]; (ii) in the holding area just before entering the operating theater [T2]; and (iii) after leaving [T3]. Additionally, at [T3], both parent and attending anesthetist evaluated the child's anxiety using a visual analogue scale. The anesthetist also filled out the Induction Compliance Checklist. On the state anxiety subscale, APAIS parental anxiety at T2 (P = 0.015) and T3 (P = 0.009) was lower in the AVA intervention group than in the control group. After induction, the child's anxiety rating by the anesthetist was significantly lower than by the parent, in both intervention and control groups. Preoperative AVA shown to parents immediately before induction moderates the increase in anxiety associated with the anesthetic induction of their child. Present results suggest that behavioral characteristics seem better predictors of child's anxiety during induction than anxiety ratings per se and that anesthetists are better than parents in predicting child's anxiety during induction. © 2011 Blackwell Publishing Ltd.
Screenometer: a device for sampling vegetative screening in forested areas
Victor A. Rudis
1985-01-01
A-device for estimating the degree to which vegetation and other obstructions screen forested areas has been adapted to an extensive sampling design for forest surveys. Procedures are recommended to assure that uniform measurements can be made. Examination of sources of sampling variation (observers, points within sampled locations, series of observations within points...
Communication target object recognition for D2D connection with feature size limit
NASA Astrophysics Data System (ADS)
Ok, Jiheon; Kim, Soochang; Kim, Young-hoon; Lee, Chulhee
2015-03-01
Recently, a new concept of device-to-device (D2D) communication, which is called "point-and-link communication" has attracted great attentions due to its intuitive and simple operation. This approach enables user to communicate with target devices without any pre-identification information such as SSIDs, MAC addresses by selecting the target image displayed on the user's own device. In this paper, we present an efficient object matching algorithm that can be applied to look(point)-and-link communications for mobile services. Due to the limited channel bandwidth and low computational power of mobile terminals, the matching algorithm should satisfy low-complexity, low-memory and realtime requirements. To meet these requirements, we propose fast and robust feature extraction by considering the descriptor size and processing time. The proposed algorithm utilizes a HSV color histogram, SIFT (Scale Invariant Feature Transform) features and object aspect ratios. To reduce the descriptor size under 300 bytes, a limited number of SIFT key points were chosen as feature points and histograms were binarized while maintaining required performance. Experimental results show the robustness and the efficiency of the proposed algorithm.
Fully 3D printed integrated reactor array for point-of-care molecular diagnostics.
Kadimisetty, Karteek; Song, Jinzhao; Doto, Aoife M; Hwang, Young; Peng, Jing; Mauk, Michael G; Bushman, Frederic D; Gross, Robert; Jarvis, Joseph N; Liu, Changchun
2018-06-30
Molecular diagnostics that involve nucleic acid amplification tests (NAATs) are crucial for prevention and treatment of infectious diseases. In this study, we developed a simple, inexpensive, disposable, fully 3D printed microfluidic reactor array that is capable of carrying out extraction, concentration and isothermal amplification of nucleic acids in variety of body fluids. The method allows rapid molecular diagnostic tests for infectious diseases at point of care. A simple leak-proof polymerization strategy was developed to integrate flow-through nucleic acid isolation membranes into microfluidic devices, yielding a multifunctional diagnostic platform. Static coating technology was adopted to improve the biocompatibility of our 3D printed device. We demonstrated the suitability of our device for both end-point colorimetric qualitative detection and real-time fluorescence quantitative detection. We applied our diagnostic device to detection of Plasmodium falciparum in plasma samples and Neisseria meningitides in cerebrospinal fluid (CSF) samples by loop-mediated, isothermal amplification (LAMP) within 50 min. The detection limits were 100 fg for P. falciparum and 50 colony-forming unit (CFU) for N. meningitidis per reaction, which are comparable to that of benchtop instruments. This rapid and inexpensive 3D printed device has great potential for point-of-care molecular diagnosis of infectious disease in resource-limited settings. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Pandey, R. K.; Sathiyanarayanan, Rajesh; Kwon, Unoh; Narayanan, Vijay; Murali, K. V. R. M.
2013-07-01
We investigate the physical properties of a portion of the gate stack of an ultra-scaled complementary metal-oxide-semiconductor (CMOS) device. The effects of point defects, such as oxygen vacancy, oxygen, and aluminum interstitials at the HfO2/TiN interface, on the effective work function of TiN are explored using density functional theory. We compute the diffusion barriers of such point defects in the bulk TiN and across the HfO2/TiN interface. Diffusion of these point defects across the HfO2/TiN interface occurs during the device integration process. This results in variation of the effective work function and hence in the threshold voltage variation in the devices. Further, we simulate the effects of varying the HfO2/TiN interface stoichiometry on the effective work function modulation in these extremely-scaled CMOS devices. Our results show that the interface rich in nitrogen gives higher effective work function, whereas the interface rich in titanium gives lower effective work function, compared to a stoichiometric HfO2/TiN interface. This theoretical prediction is confirmed by the experiment, demonstrating over 700 meV modulation in the effective work function.
Bruno Garza, J L; Young, J G
2015-01-01
Extended use of conventional computer input devices is associated with negative musculoskeletal outcomes. While many alternative designs have been proposed, it is unclear whether these devices reduce biomechanical loading and musculoskeletal outcomes. To review studies describing and evaluating the biomechanical loading and musculoskeletal outcomes associated with conventional and alternative input devices. Included studies evaluated biomechanical loading and/or musculoskeletal outcomes of users' distal or proximal upper extremity regions associated with the operation of alternative input devices (pointing devices, mice, other devices) that could be used in a desktop personal computing environment during typical office work. Some alternative pointing device designs (e.g. rollerbar) were consistently associated with decreased biomechanical loading while other designs had inconsistent results across studies. Most alternative keyboards evaluated in the literature reduce biomechanical loading and musculoskeletal outcomes. Studies of other input devices (e.g. touchscreen and gestural controls) were rare, however, those reported to date indicate that these devices are currently unsuitable as replacements for traditional devices. Alternative input devices that reduce biomechanical loading may make better choices for preventing or alleviating musculoskeletal outcomes during computer use, however, it is unclear whether many existing designs are effective.
Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Vigier, Jean Pierre; Merckx, Jacques
2012-01-01
The use of totally implantable venous access devices developed as a medical device allowing mid- and long-term, frequent, repeated, or continuous injection of therapeutic products, by vascular, cavitary, or perineural access. The effective flushing of these devices is a central element to assure long-lasting use. Our experimental work demonstrates that directing the Huber point needle opening in the diametrically opposite direction of the implantable port exit channel increases the flushing efficiency. These results are consolidated by numerical computations, which support recommendations not only for their maintenance, but also for their use.
Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Vigier, Jean Pierre; Merckx, Jacques
2012-01-01
The use of totally implantable venous access devices developed as a medical device allowing mid- and long-term, frequent, repeated, or continuous injection of therapeutic products, by vascular, cavitary, or perineural access. The effective flushing of these devices is a central element to assure long-lasting use. Our experimental work demonstrates that directing the Huber point needle opening in the diametrically opposite direction of the implantable port exit channel increases the flushing efficiency. These results are consolidated by numerical computations, which support recommendations not only for their maintenance, but also for their use. PMID:23166455
An Instantaneous Low-Cost Point-of-Care Anemia Detection Device
Punter-Villagrasa, Jaime; Cid, Joan; Páez-Avilés, Cristina; Rodríguez-Villarreal, Ivón; Juanola-Feliu, Esteve; Colomer-Farrarons, Jordi; Miribel-Català, Pere Ll.
2015-01-01
We present a small, compact and portable device for point-of-care instantaneous early detection of anemia. The method used is based on direct hematocrit measurement from whole blood samples by means of impedance analysis. This device consists of a custom electronic instrumentation and a plug-and-play disposable sensor. The designed electronics rely on straightforward standards for low power consumption, resulting in a robust and low consumption device making it completely mobile with a long battery life. Another approach could be powering the system based on other solutions like indoor solar cells, or applying energy-harvesting solutions in order to remove the batteries. The sensing system is based on a disposable low-cost label-free three gold electrode commercial sensor for 50 μL blood samples. The device capability for anemia detection has been validated through 24 blood samples, obtained from four hospitalized patients at Hospital Clínic. As a result, the response, effectiveness and robustness of the portable point-of-care device to detect anemia has been proved with an accuracy error of 2.83% and a mean coefficient of variation of 2.57% without any particular case above 5%. PMID:25690552
NASA Astrophysics Data System (ADS)
Cooley, Christopher G.
2017-09-01
This study investigates the vibration and dynamic response of a system of coupled electromagnetic vibration energy harvesting devices that each consist of a proof mass, elastic structure, electromagnetic generator, and energy harvesting circuit with inductance, resistance, and capacitance. The governing equations for the coupled electromechanical system are derived using Newtonian mechanics and Kirchhoff circuit laws for an arbitrary number of these subsystems. The equations are cast in matrix operator form to expose the device's vibration properties. The device's complex-valued eigenvalues and eigenvectors are related to physical characteristics of its vibration. Because the electrical circuit has dynamics, these devices have more natural frequencies than typical electromagnetic vibration energy harvesters that have purely resistive circuits. Closed-form expressions for the steady state dynamic response and average power harvested are derived for devices with a single subsystem. Example numerical results for single and double subsystem devices show that the natural frequencies and vibration modes obtained from the eigenvalue problem agree with the resonance locations and response amplitudes obtained independently from forced response calculations. This agreement demonstrates the usefulness of solving eigenvalue problems for these devices. The average power harvested by the device differs substantially at each resonance. Devices with multiple subsystems have multiple modes where large amounts of power are harvested.
HIT-SI Injector Voltage Measurements Using Injector Langmuir Probes
NASA Astrophysics Data System (ADS)
Aboul Hosn, Rabih; Smith, Roger; Jarboe, Thomas
2006-10-01
A pair of Langmuir probe arrays have been designed and built to measure floating potentials of the plasma at the injector mouth of the HIT-SI device. The Helicity Injected Torus using Steady Inductive Helicity Injection (HIT-SI) [1,2] is a ``bow tie'' spheromak using an electrodeless formation and sustainment concept. HIT-SI is powered by two inductive helicity injectors operated in quadrature to maintain a constant helicity injection rate. The electric probes consist of an array of four floating potential Langmuir probes measuring the voltage distribution in each injector from the shell to midpoint of the injector mouth. The probe measurements combine to determine the part of the injector loop voltage driving the n = 0 spheromak equilibrium region. Preliminary data suggest the spheromak voltage is the loop voltage minus the nearly constant injector voltage of 150-180 volts. These probe data will be used to calculate the helicity decay time of the spheromak. [1] T. R. Jarboe. Steady inductive helicity injection and its application to a high-beta spheromak. Fusion Technology, 36(1):85--91, July 1999. [2] P.E.Sieck et al., ``Demonstration of Steady Inductive Helicity Injection'', Nuc. Fusion, in press (2006).
36 CFR Appendix C to Part 1191 - Architectural Barriers Act: Scoping
Code of Federal Regulations, 2014 CFR
2014-07-01
.... That portion of a room or space where the play or practice of a sport occurs. Assembly Area. A building... devices to bypass the acoustical space between a sound source and a listener by means of induction loop, radio frequency, infrared, or direct-wired equipment. Boarding Pier. A portion of a pier where a boat is...
Alecu, C; Cuignet-Royer, E; Mertes, P M; Salvi, P; Vespignani, H; Lambert, M; Bouaziz, H; Benetos, A
2010-11-01
The aim of the present study was to establish whether elevated carotid-femoral pulse wave velocity (c-fPWV), an indicator of aortic stiffness, assessed before surgery, is correlated with variations in arterial pressure (AP) during induction of anaesthesia in elderly patients undergoing non-cardiovascular surgery. c-fPWV was measured with the PulsePen(®) device during pre-surgical anaesthetic evaluation. Monitoring included electrocardiography, pulse oximetry, non-invasive AP, heart rate, bispectral index (BIS), and oxygen concentration during induction of anaesthesia with propofol and remifentanil. Anaesthesia was induced so as to maintain BIS values between 40 and 50. Forty-five patients, aged [mean (sd)] 71.1 (5.8) yr, were studied. The mean value of c-fPWV was 12.1 (3.9) m s⁻¹. There was no correlation between hypotension during anaesthesia induction and total dosage or rate of administration of propofol or remifentanil. In univariate analysis, only age and PWV significantly correlated with the decreases in AP, and the association between c-fPWV and a decrease in AP was also seen in multivariate analysis (r = 0.36, P< 0.05). Patients classified as having 'high stiffness' (c-fPWV ≥ 12.9 m s⁻¹) had 25% further decrease in systolic AP during anaesthesia induction than those with lower PWV [75.2 (5.7) vs 60.2 (4.2) mm Hg, P < 0.05]. Increased aortic stiffness, as assessed by PWV measured during preoperative anaesthetic evaluation, is associated with more pronounced hypotension during induction of anaesthesia. Measurement of aortic stiffness in the elderly may thus represent a valid indicator of the risk of hypotension during anaesthesia induction.
Point-of-care diagnostics for niche applications.
Cummins, Brian M; Ligler, Frances S; Walker, Glenn M
2016-01-01
Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. Copyright © 2016 Elsevier Inc. All rights reserved.
Pointright: a system to redirect mouse and keyboard control among multiple machines
Johanson, Bradley E [Palo Alto, CA; Winograd, Terry A [Stanford, CA; Hutchins, Gregory M [Mountain View, CA
2008-09-30
The present invention provides a software system, PointRight, that allows for smooth and effortless control of pointing and input devices among multiple displays. With PointRight, a single free-floating mouse and keyboard can be used to control multiple screens. When the cursor reaches the edge of a screen it seamlessly moves to the adjacent screen and keyboard control is simultaneously redirected to the appropriate machine. Laptops may also redirect their keyboard and pointing device, and multiple pointers are supported simultaneously. The system automatically reconfigures itself as displays go on, go off, or change the machine they display.
NASA Astrophysics Data System (ADS)
Sebald, Thomas
2008-10-01
Electrostatic protection is an issue for all masks, whether during mask production, shipping, storage, handling or inspection and exposure. Up to now, only manual electrostatic field measurements, or expensive and elaborate analyses with Canary reticles have given hints about the risks of pattern damage by ESD events. A new test device is being introduced, which consists of electrostatic field sensors, integrated INSIDE a closed fused quartz housing which has the outside dimensions of a 6 inch mask. This device can be handled and used like a normal 6 inch reticle. It can be handled and processed while recording the electrostatic charges on the chrome patterns created by friction or field induction just as a reticle would "see" during normal processing.
Advanced Measurement Devices for the Microgravity Electromagnetic Levitation Facility EML
NASA Technical Reports Server (NTRS)
Brillo, Jurgen; Fritze, Holger; Lohofer, Georg; Schulz, Michal; Stenzel, Christian
2012-01-01
This paper reports on two advanced measurement devices for the microgravity electromagnetic levitation facility (EML), which is currently under construction for the use onboard the "International Space Station (ISS)": the "Sample Coupling Electronics (SCE)" and the "Oxygen Sensing and Control Unit (OSC)". The SCE measures by a contactless, inductive method the electrical resistivity and the diameter of a spherical levitated metallic droplet by evaluating the voltage and electrical current applied to the levitation coil. The necessity of the OSC comes from the insight that properties like surface tension or, eventually, viscosity cannot seriously be determined by the oscillating drop method in the EML facility without knowing the conditions of the surrounding atmosphere. In the following both measurement devices are explained and laboratory test results are presented.
Watada, Masaya; Saisho, Ryohei; Kim, Yong-Jae; Ohuchi, Katsuhiro; Takatani, Setsuo; Um, Yong-Su
2007-01-01
All implantable devices, such as an artificial heart, an artificial lung, a pacemaker, a defibrillator, need electric power. So the electric power supply through the skin is requested. Then, it is transcutaneous energy transmission system (TETS) that has been studied and used a lot. TETS is the system which performs an electric power supply by non-contact transcutaneously using the electromagnetic induction phenomenon of an external primary side coil and a secondary side coil in human body. In this research, we are developing the core type TETS which applied for the implantable devices. In this paper, corresponding to various conditions, such as a difference in required electric power and transmission distance change, the core type transformer which can hold high transmission efficiency is designed.
Coherence, Charging, and Spin Effects in Quantum Dots and Point Contacts
2001-12-01
requires changing the direction of the external field. Considering the typical fields involved (several tesla) and the high- inductance superconducting ...84 6-5 QPC nonlinear conductance...86 6-6 Nonlinear transconductance colorscales
All Optical Solution for Free Space Optics Point to Point Links
NASA Astrophysics Data System (ADS)
Hirayama, Daigo
Optical network systems are quickly replacing electrical network systems. Optical systems provide better bandwidth, faster data rates, better security to networks, and are less susceptible to noise. Free Space Optics (systems) still rely on numerous electrical systems such as the modulation and demodulation systems to convert optical signals to electrical signals for the transmitting laser. As the concept of the entirely optical network becomes more realizable, the electrical components of the FSO system will become a hindrance to communications. The focus of this thesis is to eliminate the electrical devices for the FSO point to point links by replacing them with optical devices. The concept is similar to an extended beam connector. However, where an extended beam connector deals with a gap of a few millimeters, my focus looks at distances from 100 meters to one kilometer. The aim is to achieve a detectable signal of 1nW at a distance of 500 meters at a wavelength of 1500-1600nm. This leads to application in building to building links and mobile networks. The research examines the design of the system in terms of generating the wave, the properties of the fiber feeding the wave, and the power necessary to achieve a usable distance. The simulation is executed in Code V by Synopsys, which is an industry standard to analyze optical systems. A usable device with a range of around 500m was achieved with an input power of 1mW. The approximations of the phase function resulted in some aberrations to the profile of the beam, but were not very detrimental to the function of the device. The removal of electrical devices from a FSO point to point link decreased the power used to establish the link and decreased the cost.
SU-F-T-264: VMAT QA with 2D Radiation Measuring Equipment Attached to Gantry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fung, A
2016-06-15
Purpose: To introduce a method of VMAT QA by 2D measuring device. The 2D device is attached to the gantry throughout measurement duration. This eliminates error caused by the angular dependence of the radiation detectors. Methods: A 2D radiation measuring device was attached to the gantry of linear accelerator. The center of the detector plane was at the isocenter. For each patient plan, two verification plans were created for QA purpose. One was like an ordinary VMAT plan, to be used for radiation delivery. The other is a plan with gantry angle fixed at zero, so the dose distribution asmore » seen by the rotating 2D device. Points above 10% dose threshold were analyzed. Data is in tolerance if it fits within the 3 mm or 3% dose gamma criteria. For each patient, the plan was passed when 95% of all the points in the 2D matrix fit the gamma criteria. The following statistics were calculated: number of patient plans passed, percentage of all points passed, average percentage difference of all points. Results: VMAT QA was performed for patients during one year in our department, and the results were analyzed. All irradiation was with 6 MV photon beam. Each plan has calculated and measured doses compared. After collecting one year’s result, with 81 patient plans analyzed, all (100%) of the plans passed the gamma criteria. Of the points analyzed from all plans, 98.8% of all points passed. Conclusion: This method of attaching a 2D measuring device on the linac gantry proves to be an accurate way for VMAT QA. It is simple to use and low cost, and it eliminates the problem of directional dependence.« less
Consumer Sleep Technologies: A Review of the Landscape.
Ko, Ping-Ru T; Kientz, Julie A; Choe, Eun Kyoung; Kay, Matthew; Landis, Carol A; Watson, Nathaniel F
2015-12-15
To review sleep related consumer technologies, including mobile electronic device "apps," wearable devices, and other technologies. Validation and methodological transparency, the effect on clinical sleep medicine, and various social, legal, and ethical issues are discussed. We reviewed publications from the digital libraries of the Association for Computing Machinery, Institute of Electrical and Electronics Engineers, and PubMed; publications from consumer technology websites; and mobile device app marketplaces. Search terms included "sleep technology," "sleep app," and "sleep monitoring." Consumer sleep technologies are categorized by delivery platform including mobile device apps (integrated with a mobile operating system and utilizing mobile device functions such as the camera or microphone), wearable devices (on the body or attached to clothing), embedded devices (integrated into furniture or other fixtures in the native sleep environment), accessory appliances, and conventional desktop/website resources. Their primary goals include facilitation of sleep induction or wakening, self-guided sleep assessment, entertainment, social connection, information sharing, and sleep education. Consumer sleep technologies are changing the landscape of sleep health and clinical sleep medicine. These technologies have the potential to both improve and impair collective and individual sleep health depending on method of implementation. © 2015 American Academy of Sleep Medicine.
Zheng, Sarah Y; Dhruva, Sanket S; Redberg, Rita F
2017-08-15
High-risk medical devices often undergo modifications, which are approved by the US Food and Drug Administration (FDA) through various kinds of premarket approval (PMA) supplements. There have been multiple high-profile recalls of devices approved as PMA supplements. To characterize the quality of the clinical studies and data (strength of evidence) used to support FDA approval of panel-track supplements (a type of PMA supplement pathway that is used for significant changes in a device or indication for use and always requires clinical data). Descriptive study of clinical studies supporting panel-track supplements approved by the FDA between April 19, 2006, and October 9, 2015. Panel-track supplement approval. Methodological quality of studies including randomization, blinding, type of controls, clinical vs surrogate primary end points, use of post hoc analyses, and reporting of age and sex. Eighty-three clinical studies supported the approval of 78 panel-track supplements, with 71 panel-track supplements (91%) supported by a single study. Of the 83 studies, 37 (45%) were randomized clinical trials and 25 (30%) were blinded. The median number of patients per study was 185 (interquartile range, 75-305), and the median follow-up duration was 180 days (interquartile range, 84-270 days). There were a total of 150 primary end points (mean [SD], 1.8 [1.2] per study), and 57 primary end points (38%) were compared with controls. Of primary end points with controls, 6 (11%) were retrospective controls and 51 (89%) were active controls. One hundred twenty-one primary end points (81%) were surrogate end points. Thirty-three studies (40%) did not report age and 25 (30%) did not report sex for all enrolled patients. The FDA required postapproval studies for 29 of 78 (37%) panel-track supplements. Among clinical studies used to support FDA approval of high-risk medical device modifications, fewer than half were randomized, blinded, or controlled, and most primary outcomes were based on surrogate end points. These findings suggest that the quality of studies and data evaluated to support approval by the FDA of modifications of high-risk devices should be improved.
Thermoelectric Control Of Temperatures Of Pressure Sensors
NASA Technical Reports Server (NTRS)
Burkett, Cecil G., Jr.; West, James W.; Hutchinson, Mark A.; Lawrence, Robert M.; Crum, James R.
1995-01-01
Prototype controlled-temperature enclosure containing thermoelectric devices developed to house electronically scanned array of pressure sensors. Enclosure needed because (1) temperatures of transducers in sensors must be maintained at specified set point to ensure proper operation and calibration and (2) sensors sometimes used to measure pressure in hostile environments (wind tunnels in original application) that are hotter or colder than set point. Thus, depending on temperature of pressure-measurement environment, thermoelectric devices in enclosure used to heat or cool transducers to keep them at set point.
Fixation of operating point and measurement of turn on characteristics of IGBT F4-75R06W1E3
NASA Astrophysics Data System (ADS)
Haseena, A.; Subhash Joshi T., G.; George, Saly
2018-05-01
For the proficient operation of the Power electronic circuit, signal level performance of power electronic devices are very important. For getting good signal level characteristics, fixing operating point is very critical. Device deviates from the typical characteristics given in the datasheet due to the presence of stray components in the circuit lay out. Fixation of operating point of typical silicon IGBT and its turn on characteristics is discussed in this paper.
Richardson, John G.; Morrison, John L.; Hawkes, Grant L.
2006-07-04
An induction heating apparatus includes a measurement device for indicating an electrical resistance of a material to be heated. A controller is configured for energizing an inductor in response to the indicated resistance. An inductor may be energized with an alternating current, a characteristic of which may be selected in response to an indicated electrical resistance. Alternatively, a temperature of the material may be indicated via measuring the electrical resistance thereof and a characteristic of an alternating current for energizing the inductor may be selected in response to the temperature. Energizing the inductor may minimize the difference between a desired and indicated resistance or the difference between a desired and indicated temperature. A method of determining a temperature of at least one region of at least one material to be induction heated includes correlating a measured electrical resistance thereof to an average temperature thereof.
Matlashov, Andrei N.; Schultz, Larry J.; Espy, Michelle A.; Kraus, Robert H.; Savukov, Igor M.; Volegov, Petr L.; Wurden, Caroline J.
2011-01-01
Nuclear magnetic resonance (NMR) is widely used in medicine, chemistry and industry. One application area is magnetic resonance imaging (MRI). Recently it has become possible to perform NMR and MRI in the ultra-low field (ULF) regime requiring measurement field strengths of the order of only 1 Gauss. This technique exploits the advantages offered by superconducting quantum interference devices or SQUIDs. Our group has built SQUID based MRI systems for brain imaging and for liquid explosives detection at airport security checkpoints. The requirement for liquid helium cooling limits potential applications of ULF MRI for liquid identification and security purposes. Our experimental comparative investigation shows that room temperature inductive magnetometers may provide enough sensitivity in the 3–10 kHz range and can be used for fast liquid explosives detection based on ULF NMR technique. We describe experimental and computer-simulation results comparing multichannel SQUID based and induction coils based instruments that are capable of performing ULF MRI for liquid identification. PMID:21747638
Kinetic Inductance Memory Cell and Architecture for Superconducting Computers
NASA Astrophysics Data System (ADS)
Chen, George J.
Josephson memory devices typically use a superconducting loop containing one or more Josephson junctions to store information. The magnetic inductance of the loop in conjunction with the Josephson junctions provides multiple states to store data. This thesis shows that replacing the magnetic inductor in a memory cell with a kinetic inductor can lead to a smaller cell size. However, magnetic control of the cells is lost. Thus, a current-injection based architecture for a memory array has been designed to work around this problem. The isolation between memory cells that magnetic control provides is provided through resistors in this new architecture. However, these resistors allow leakage current to flow which ultimately limits the size of the array due to power considerations. A kinetic inductance memory array will be limited to 4K bits with a read access time of 320 ps for a 1 um linewidth technology. If a power decoder could be developed, the memory architecture could serve as the blueprint for a fast (<1 ns), large scale (>1 Mbit) superconducting memory array.
Analysis and Design of ITER 1 MV Core Snubber
NASA Astrophysics Data System (ADS)
Wang, Haitian; Li, Ge
2012-11-01
The core snubber, as a passive protection device, can suppress arc current and absorb stored energy in stray capacitance during the electrical breakdown in accelerating electrodes of ITER NBI. In order to design the core snubber of ITER, the control parameters of the arc peak current have been firstly analyzed by the Fink-Baker-Owren (FBO) method, which are used for designing the DIIID 100 kV snubber. The B-H curve can be derived from the measured voltage and current waveforms, and the hysteresis loss of the core snubber can be derived using the revised parallelogram method. The core snubber can be a simplified representation as an equivalent parallel resistance and inductance, which has been neglected by the FBO method. A simulation code including the parallel equivalent resistance and inductance has been set up. The simulation and experiments result in dramatically large arc shorting currents due to the parallel inductance effect. The case shows that the core snubber utilizing the FBO method gives more compact design.
Physics-based Control-oriented Modeling of the Current Profile Evolution in NSTX-Upgrade
NASA Astrophysics Data System (ADS)
Ilhan, Zeki; Barton, Justin; Shi, Wenyu; Schuster, Eugenio; Gates, David; Gerhardt, Stefan; Kolemen, Egemen; Menard, Jonathan
2013-10-01
The operational goals for the NSTX-Upgrade device include non-inductive sustainment of high- β plasmas, realization of the high performance equilibrium scenarios with neutral beam heating, and achievement of longer pulse durations. Active feedback control of the current profile is proposed to enable these goals. Motivated by the coupled, nonlinear, multivariable, distributed-parameter plasma dynamics, the first step towards feedback control design is the development of a physics-based, control-oriented model for the current profile evolution in response to non-inductive current drives and heating systems. For this purpose, the nonlinear magnetic-diffusion equation is coupled with empirical models for the electron density, electron temperature, and non-inductive current drives (neutral beams). The resulting first-principles-driven, control-oriented model is tailored for NSTX-U based on the PTRANSP predictions. Main objectives and possible challenges associated with the use of the developed model for control design are discussed. This work was supported by PPPL.
Shape Memory Actuation and Release Devices.
1996-10-01
shelf devices such as pyrotechnics, gas-discharge systems, paraffin wax actuators, and other electro-mechanical devices may not be able to meet...shelf devices such as pyrotechnics, gas-discharge systems, paraffin wax actuators, and other electro-mechanical devices may not be able to meet future...shard mounts. They do have wide utility as pin-pullers and single point release devices for a variety of spacecraft appendages. Parrafin based mechanisms
Bubble Point Measurements with Liquid Methane of a Screen Capillary Liquid Acquisition Device
NASA Technical Reports Server (NTRS)
Jurns, John M.; McQuillen, John B.
2009-01-01
Liquid acquisition devices (LADs) can be utilized within a propellant tank in space to deliver single-phase liquid to the engine in low gravity. One type of liquid acquisition device is a screened gallery whereby a fine mesh screen acts as a bubble filter and prevents the gas bubbles from passing through until a crucial pressure differential condition across the screen, called the bubble point, is reached. This paper presents data for LAD bubble point data in liquid methane (LCH4) for stainless steel Dutch twill screens with mesh sizes of 325 by 2300 and 200 by 1400 wires per inch. Data is presented for both saturated and sub-cooled LCH4, and is compared with predicted values.
Baharoglu, Zeynep; Babosan, Anamaria; Mazel, Didier
2014-01-01
Sub-inhibitory concentrations (sub-MIC) of antibiotics play a very important role in selection and development of resistances. Unlike Escherichia coli, Vibrio cholerae induces its SOS response in presence of sub-MIC aminoglycosides. A role for oxidized guanine residues was observed, but the mechanisms of this induction remained unclear. To select for V. cholerae mutants that do not induce low aminoglycoside-mediated SOS induction, we developed a genetic screen that renders induction of SOS lethal. We identified genes involved in this pathway using two strategies, inactivation by transposition and gene overexpression. Interestingly, we obtained mutants inactivated for the expression of proteins known to destabilize the RNA polymerase complex. Reconstruction of the corresponding mutants confirmed their specific involvement in induction of SOS by low aminoglycoside concentrations. We propose that DNA lesions formed on aminoglycoside treatment are repaired through the formation of single-stranded DNA intermediates, inducing SOS. Inactivation of functions that dislodge RNA polymerase leads to prolonged stalling on these lesions, which hampers SOS induction and repair and reduces viability under antibiotic stress. The importance of these mechanisms is illustrated by a reduction of aminoglycoside sub-MIC. Our results point to a central role for transcription blocking at DNA lesions in SOS induction, so far underestimated. PMID:24319148
Baharoglu, Zeynep; Babosan, Anamaria; Mazel, Didier
2014-02-01
Sub-inhibitory concentrations (sub-MIC) of antibiotics play a very important role in selection and development of resistances. Unlike Escherichia coli, Vibrio cholerae induces its SOS response in presence of sub-MIC aminoglycosides. A role for oxidized guanine residues was observed, but the mechanisms of this induction remained unclear. To select for V. cholerae mutants that do not induce low aminoglycoside-mediated SOS induction, we developed a genetic screen that renders induction of SOS lethal. We identified genes involved in this pathway using two strategies, inactivation by transposition and gene overexpression. Interestingly, we obtained mutants inactivated for the expression of proteins known to destabilize the RNA polymerase complex. Reconstruction of the corresponding mutants confirmed their specific involvement in induction of SOS by low aminoglycoside concentrations. We propose that DNA lesions formed on aminoglycoside treatment are repaired through the formation of single-stranded DNA intermediates, inducing SOS. Inactivation of functions that dislodge RNA polymerase leads to prolonged stalling on these lesions, which hampers SOS induction and repair and reduces viability under antibiotic stress. The importance of these mechanisms is illustrated by a reduction of aminoglycoside sub-MIC. Our results point to a central role for transcription blocking at DNA lesions in SOS induction, so far underestimated.
Stable Spheromaks with Profile Control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fowler, T K; Jayakumar, R
A spheromak equilibrium with zero edge current is shown to be stable to both ideal MHD and tearing modes that normally produce Taylor relaxation in gun-injected spheromaks. This stable equilibrium differs from the stable Taylor state in that the current density j falls to zero at the wall. Estimates indicate that this current profile could be sustained by non-inductive current drive at acceptable power levels. Stability is determined using the NIMROD code for linear stability analysis. Non-linear NIMROD calculations with non-inductive current drive could point the way to improved fusion reactors.
Field oriented control of induction motors
NASA Technical Reports Server (NTRS)
Burrows, Linda M.; Zinger, Don S.; Roth, Mary Ellen
1990-01-01
Induction motors have always been known for their simple rugged construction, but until lately were not suitable for variable speed or servo drives due to the inherent complexity of the controls. With the advent of field oriented control (FOC), however, the induction motor has become an attractive option for these types of drive systems. An FOC system which utilizes the pulse population modulation method to synthesize the motor drive frequencies is examined. This system allows for a variable voltage to frequency ratio and enables the user to have independent control of both the speed and torque of an induction motor. A second generation of the control boards were developed and tested with the next point of focus being the minimization of the size and complexity of these controls. Many options were considered with the best approach being the use of a digital signal processor (DSP) due to its inherent ability to quickly evaluate control algorithms. The present test results of the system and the status of the optimization process using a DSP are discussed.
Payne, Lloyd R.; Cole, David L.
2010-03-30
A fragment capture device for use in explosive containment. The device comprises an assembly of at least two rows of bars positioned to eliminate line-of-sight trajectories between the generation point of fragments and a surrounding containment vessel or asset. The device comprises an array of at least two rows of bars, wherein each row is staggered with respect to the adjacent row, and wherein a lateral dimension of each bar and a relative position of each bar in combination provides blockage of a straight-line passage of a solid fragment through the adjacent rows of bars, wherein a generation point of the solid fragment is located within a cavity at least partially enclosed by the array of bars.
Creation and use of a survey instrument for comparing mobile computing devices.
Macri, Jennifer M; Lee, Paul P; Silvey, Garry M; Lobach, David F
2005-01-01
Both personal digital assistants (PDAs) and tablet computers have emerged to facilitate data collection at the point of care. However, little research has been reported comparing these mobile computing devices in specific care settings. In this study we present an approach for comparing functionally identical applications on a Palm operating system-based PDA and a Windows-based tablet computer for point-of-care documentation of clinical observations by eye care professionals when caring for patients with diabetes. Eye-care professionals compared the devices through focus group sessions and through validated usability surveys. This poster describes the development and use of the survey instrument used for comparing mobile computing devices.
Dunne, Simon; Gallagher, Pamela; Matthews, Anne
2015-01-01
Using a terror management theory framework, this study investigated if providing mortality reminders or self-esteem threats would lead participants to exhibit avoidant responses toward a point-of-care testing device for cardiovascular disease risk and if the nature of the device served to diminish the existential threat of cardiovascular disease. One hundred and twelve participants aged 40-55 years completed an experimental questionnaire. Findings indicated that participants were not existentially threatened by established terror management methodologies, potentially because of cross-cultural variability toward such methodologies. Highly positive appraisals of the device also suggest that similar technologies may beneficially affect the uptake of screening behaviors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Thomas
The design features developed for the Spherical Tokamak (ST) in the PPPL pilot plant study was used as the starting point in developing designs to meet the mission of a Fusion Nuclear Science Facility (FNSF) considering a range of machine sizes based on the influence of tritium consumption and maintenance strategies. The compact nature of a steady state operated ST device for this mission pushes operating conditions and places challenges in the design of components, device maintenance and the integration of supports and services. This paper reviews the general arrangement, design details and maintenance strategy of the ST-FNSF device coremore » for a 1.6-m and 1.0-m device; operating points which bracket the region between purchasing and breeding tritium.« less
Phosphorus doped graphene by inductively coupled plasma and triphenylphosphine treatments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shin, Dong-Wook, E-mail: shindong37@skku.edu; Kim, Tae Sung; Yoo, Ji-Beom, E-mail: jbyoo@skku.edu
Highlights: • Substitution doping is a promising method for opening the energy band gap of graphene. • Substitution doping with phosphorus in the graphene lattice has numerous advantage such as high band gap, low formation energy, and high net charge density compared to nitrogen. • V{sub dirac} of Inductively coupled plasma (ICP) and triphenylphosphine (TPP) treated graphene was −57 V, which provided clear evidence of n-type doping. • Substitutional doping of graphene with phosphorus is verified by the XPS spectra of P 2p core level and EELS mapping of phosphorus. • The chemical bonding between P and graphene is verymore » stable for a long time in air (2 months). - Abstract: Graphene is considered a host material for various applications in next-generation electronic devices. However, despite its excellent properties, one of the most important issues to be solved as an electronic material is the creation of an energy band gap. Substitution doping is a promising method for opening the energy band gap of graphene. Herein, we demonstrate the substitutional doping of graphene with phosphorus using inductively coupled plasma (ICP) and triphenylphosphine (TPP) treatments. The electrical transfer characteristics of the phosphorus doped graphene field effect transistor (GFET) have a V{sub dirac} of ∼ − 54 V. The chemical bonding between P and C was clearly observed in XPS spectra, and uniform distribution of phosphorus within graphene domains was confirmed by EELS mapping. The capability for substitutional doping of graphene with phosphorus can significantly promote the development of graphene based electronic devices.« less
Summary of the 2012 Inductive Pulsed Plasma Thruster Development and Testing Program
NASA Technical Reports Server (NTRS)
Polzin, K. A.; Martin, A. K.; Eskridge, R. H.; Kimberlin, A. C.; Addona, B. M.; Devineni, A. P.; Dugal-Whitehead, N. R.; Hallock, A. K.
2013-01-01
Inductive pulsed plasma thrusters are spacecraft propulsion devices in which energy is capacitively stored and then discharged through an inductive coil. While these devices have shown promise for operation at high efficiency on a range of propellants, many technical issues remain before they can be used in flight applications. A conical theta-pinch thruster geometry was fabricated and tested to investigate potential improvements in propellant utilization relative to more common, flat-plate planar coil designs. A capacitor charging system is used to permit repetitive discharging of thrusters at multiple cycles per second, with successful testing accomplished at a repetition-rate of 5 Hz at power levels of 0.9, 1.6, and 2.5 kW. The conical theta-pinch thruster geometry was tested at cone angles of 20deg, 38deg, and 60deg, with single-pulse operation at 500 J/pulse and repetitionrate operation with the 38deg model quantified through direct thrust measurement using a hanging pendulum thrust stand. A long-lifetime valve was designed and fabricated, and initial testing was performed to measure the valve response and quantify the leak rate at beginning-of-life. Subscale design and testing of a capacitor charging system required for operation on a spacecraft is reported, providing insights into the types of components needed in the circuit topology employed. On a spacecraft, this system would accept as input a lower voltage from the spacecraft DC bus and boost the output to the high voltage required to charge the capacitors of the thruster.
Turillazzi, Emanuela; Monaci, Fabrizio; Neri, Margherita; Pomara, Cristoforo; Riezzo, Irene; Baroni, Davide; Fineschi, Vittorio
2010-04-15
In most deaths caused by explosive, the victim's body becomes a depot for fragments of explosive materials, so contributing to the collection of trace evidence which may provide clues about the specific type of device used with explosion. Improvised explosive devices are used which contain "homemade" explosives rather than high explosives because of the relative ease with which such components can be procured. Many methods such as chromatography-mass spectrometry, scanning electron microscopy, stereomicroscopy, capillary electrophoresis are available for use in the identification of explosive residues on objects and bomb fragments. Identification and reconstruction of the distribution of explosive residues on the decedent's body may give additional hints in assessing the position of the victim in relation to the device. Traditionally these residues are retrieved by swabbing the body and clothing during the early phase, at autopsy. Gas chromatography-mass spectrometry and other analytical methods may be used to analyze the material swabbed from the victim body. The histological examination of explosive residues on skin samples collected during the autopsy may reveal significant details. The information about type, quantity and particularly about anatomical distribution of explosive residues obtained utilizing confocal laser scanning microscope (CLSM) together with inductively coupled plasma atomic emission spectrometer (ICP-AES), may provide very significant evidence in the clarification and reconstruction of the explosive-related events. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
The Helicity Injected Torus (HIT) Program
NASA Astrophysics Data System (ADS)
Jarboe, T. R.; Gu, P.; Hamp, W.; Izzo, V.; Jewell, P.; Liptac, J.; McCollam, K. J.; Nelson, B. A.; Raman, R.; Redd, A. J.; Shumlak, U.; Sieck, P. E.; Smith, R. J.; Jain, K. K.; Nagata, M.; Uyama, T.
2000-10-01
The purpose of the Helicity Injected Torus (HIT) program is to develop current drive techniques for low-aspect-ratio toroidal plasmas. The present HIT-II spherical tokamak experiment is capable of both Coaxial Helicity Injection (CHI) and transformer action current drive. The HIT-II device itself is modestly sized (major radius R = 0.3 m, minor radius a = 0.2 m, with an on-axis magnetic field of up to Bo = 0.5 T), but has demonstrated toroidal plasma currents of up to 200 kA, using either CHI or transformer drive. An overview of ongoing research on HIT-II plasmas, including recent results, will be presented. An electron-locking model has been developed for helicity injection current drive; a description of this model will be presented, as well as comparisons to experimental results from the HIT and HIT-II devices. Empirical results from both the HIT program and past spheromak research, buttressed by theoretical developments, have led to the design of the upcoming HIT-SI (Helicity Injected Torus with Steady Inductive helicity injection) device (T.R. Jarboe, Fusion Technology 36, p. 85, 1999). HIT-SI will be able to form a high-beta spheromak, a low aspect ratio RFP or a spherical tokamak using constant inductive helicity injection. The HIT-SI design and construction progress will be presented.
He, Wenjing; Zhu, Yuanzhong; Wang, Wenzhou; Zou, Kai; Zhang, Kai; He, Chao
2017-04-01
Pulsed magnetic field gradients generated by gradient coils are widely used in signal location in magnetic resonance imaging (MRI). However, gradient coils can also induce eddy currents in final magnetic field in the nearby conducting structures which lead to distortion and artifact in images, misguiding clinical diagnosis. We tried in our laboratory to measure the magnetic field of gradient-induced eddy current in 1.5 T superconducting magnetic resonance imaging device; and extracted key parameters including amplitude and time constant of exponential terms according to inductance-resistance series mathematical module. These parameters of both self-induced component and crossing component are useful to design digital filters to implement pulse pre-emphasize to reshape the waveform. A measure device that is a basement equipped with phantoms and receiving coils was designed and placed in the isocenter of the magnetic field. By applying testing sequence, contrast experiments were carried out in a superconducting magnet before and after eddy current compensation. Sets of one dimension signal were obtained as raw data to calculate gradient-induced eddy currents. Curve fitting by least squares method was also done to match inductance-resistance series module. The results also illustrated that pulse pre-emphasize measurement with digital filter was correct and effective in reducing eddy current effect. Pre-emphasize waveform was developed based on system function. The usefulness of pre-emphasize measurement in reducing eddy current was confirmed and the improvement was also presented. All these are valuable for reducing artifact in magnetic resonance imaging device.
NIMROD Simulations of the HIT-SI and HIT-SI3 Devices
NASA Astrophysics Data System (ADS)
Morgan, Kyle; Jarboe, Tom; Hossack, Aaron; Chandra, Rian; Everson, Chris
2017-10-01
The Helicity Injected Torus with Steady Inductive helicity injection (HIT-SI) experiment uses a set of inductively driven helicity injectors to apply non-axisymmetric current drive on the edge of the plasma, driving an axisymmetric spheromak equilibrium in a central confinement volume. Significant improvements have been made to extended MHD modeling of HIT-SI, with both the resolution of disagreement at high injector frequencies in HIT-SI in addition to successes with the new upgraded HIT-SI3 device. Previous numerical studies of HIT-SI, using a zero-beta eMHD model, focused on operations with a drive frequency of 14.5 kHz, and found reduced agreement with both the magnetic profile and current amplification at higher frequencies (30-70 kHz). HIT-SI3 has three helicity injectors which are able to operate with different mode structures of perturbations through the different relative temporal phasing of the injectors. Simulations that allow for pressure gradients have been performed in the parameter regimes of both devices using the NIMROD code and show improved agreement with experimental results, most notably capturing the observed Shafranov-shift due to increased beta observed at higher finj in HIT-SI and the variety of toroidal perturbation spectra available in HIT-SI3. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Fusion Energy Sciences under Award Number DE-FG02- 96ER54361.
AIRE-induced apoptosis is associated with nuclear translocation of stress sensor protein GAPDH
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liiv, Ingrid, E-mail: ingrid.liiv@ut.ee; Haljasorg, Uku; Kisand, Kai
2012-06-22
Highlights: Black-Right-Pointing-Pointer AIRE induces apoptosis in epithelial cells. Black-Right-Pointing-Pointer CARD domain of AIRE is sufficient for apoptosis induction. Black-Right-Pointing-Pointer AIRE induced apoptosis involves GAPDH translocation to the nuclei. Black-Right-Pointing-Pointer Deprenyl inhibits AIRE induced apoptosis. -- Abstract: AIRE (Autoimmune Regulator) has a central role in the transcriptional regulation of self-antigens in medullary thymic epithelial cells, which is necessary for negative selection of autoreactive T cells. Recent data have shown that AIRE can also induce apoptosis, which may be linked to cross-presentation of these self-antigens. Here we studied AIRE-induced apoptosis using AIRE over-expression in a thymic epithelial cell line as well asmore » doxycycline-inducible HEK293 cells. We show that the HSR/CARD domain in AIRE together with a nuclear localization signal is sufficient to induce apoptosis. In the nuclei of AIRE-positive cells, we also found an increased accumulation of a glycolytic enzyme, glyceraldehyde-3-phosphate (GAPDH) reflecting cellular stress and apoptosis. Additionally, AIRE-induced apoptosis was inhibited with an anti-apoptotic agent deprenyl that blocks GAPDH nitrosylation and nuclear translocation. We propose that the AIRE-induced apoptosis pathway is associated with GAPDH nuclear translocation and induction of NO-induced cellular stress in AIRE-expressing cells.« less
Analysis of Uncertainty in a Middle-Cost Device for 3D Measurements in BIM Perspective
Sánchez, Alonso; Naranjo, José-Manuel; Jiménez, Antonio; González, Alfonso
2016-01-01
Medium-cost devices equipped with sensors are being developed to get 3D measurements. Some allow for generating geometric models and point clouds. Nevertheless, the accuracy of these measurements should be evaluated, taking into account the requirements of the Building Information Model (BIM). This paper analyzes the uncertainty in outdoor/indoor three-dimensional coordinate measures and point clouds (using Spherical Accuracy Standard (SAS) methods) for Eyes Map, a medium-cost tablet manufactured by e-Capture Research & Development Company, Mérida, Spain. To achieve it, in outdoor tests, by means of this device, the coordinates of targets were measured from 1 to 6 m and cloud points were obtained. Subsequently, these were compared to the coordinates of the same targets measured by a Total Station. The Euclidean average distance error was 0.005–0.027 m for measurements by Photogrammetry and 0.013–0.021 m for the point clouds. All of them satisfy the tolerance for point cloud acquisition (0.051 m) according to the BIM Guide for 3D Imaging (General Services Administration); similar results are obtained in the indoor tests, with values of 0.022 m. In this paper, we establish the optimal distances for the observations in both, Photogrammetry and 3D Photomodeling modes (outdoor) and point out some working conditions to avoid in indoor environments. Finally, the authors discuss some recommendations for improving the performance and working methods of the device. PMID:27669245
Ansari, Edward; Tomat, Catherine; Kadlub, Natacha; Diner, Patrick A; Bellocq, Thomas; Vazquez, Marie-Paule; Picard, Arnaud
2015-04-01
The authors have recently reported on the use of an internal maxillary distraction device. In this study, we report on the hard and soft tissue movements achieved with this intraoral distraction device, and the stability changes after distraction osteogenesis for maxillary hypoplasia in patients with cleft lip and palate. Ten male patients with severe hypoplasia of the maxilla, with complete uni- or bilateral cleft lip and palate were included. The mean age of the patients at the time of operation was 11.91 years (±3.41). To evaluate the distraction process and stability, superimpositions on the preoperative lateral cephalograms were performed. The mean follow-up (FU) was 15.42 months (±3.94). Cephalometric measurements at all of the maxillary hard and soft tissue points improved significantly. Maxillary point A was advanced by 8.25 mm (±3.17; P < 0.001). After distraction soft tissue point A' had advanced 7.10 mm (±2.69; P < 0.001). The soft tissue to hard tissue ratio at point A was 0.86:1 after distraction. Maxillary horizontal relapse at point A was 14.1% at FU. Vertical relapse was not significant. This rigid intraoral distraction device can be successfully used in the correction of severe maxillary hypoplasia. The marked aesthetic improvement and low psychological encumbrance make this device viable for the treatment of cleft-related hypoplasia of the maxilla. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Fabrication of a microfluidic device for the compartmentalization of neuron soma and axons.
Harris, Joseph; Lee, Hyuna; Vahidi, Behrad; Tu, Christina; Cribbs, David; Jeon, Noo Li; Cotman, Carl
2007-01-01
In this video, we demonstrate the technique of soft lithography with polydimethyl siloxane (PDMS) which we use to fabricate a microfluidic device for culturing neurons. Previously, a silicon wafer was patterned with the design for the neuron microfluidic device using SU-8 and photolithography to create a master mold, or what we simply refer to as a "master". Next, we pour the silicon polymer PDMS on top of the master which is then cured by heating the PDMS to 80 degrees C for 1 hour. The PDMS forms a negative mold of the device. The PDMS is then carefully cut and lifted away from the master. Holes are punched where the reservoirs will be and the excess PDMS trimmed away from the device. Nitrogen is used to blow away any excess debris from the device. At this point the devices are now ready for use and can either bonded to corning No. 1 cover glass with a plasma sterilizer/cleaner or can be reversibly bound to the cover glass by simply placing the device on top of the cover glass. The reversible bonding of the device to glass is covered in a separate video and requires first that the device be sterilized either with 70% ethanol or by autoclaving. Plasma treating sterilizes the devices so no further treatment is necessary. It is, however, important, when plasma-treating the devices, to add liquid to the devices within 10 minutes of the plasma treatment while the surfaces are still hydrophilic. Waiting longer than 10 minutes to add liquid to the device makes it difficult for the liquid to enter the device. The neuron devices are typically plasma-bound to cover glass and 0.5 mg/ml poly-L-lysine (PLL) in pH 8.5 borate buffer is immediately added to the device. After a minimum of 3 hours incubating with PLL, the devices are washed with dH2O water a minimum of 3 times with at least 15 minutes between each wash. Next, the water is removed and fresh media is added to the device. At this point the device is ready for use. It is important to remember at this point to never remove all the media from the device. Always leave media in the main channel.
Toroid Joining Gun. [thermoplastic welding system using induction heating
NASA Technical Reports Server (NTRS)
Buckley, J. D.; Fox, R. L.; Swaim, R J.
1985-01-01
The Toroid Joining Gun is a low cost, self-contained, portable low powered (100-400 watts) thermoplastic welding system developed at Langley Research Center for joining plastic and composite parts using an induction heating technique. The device developed for use in the fabrication of large space sructures (LSST Program) can be used in any atmosphere or in a vacuum. Components can be joined in situ, whether on earth or on a space platform. The expanded application of this welding gun is in the joining of thermoplastic composites, thermosetting composites, metals, and combinations of these materials. Its low-power requirements, light weight, rapid response, low cost, portability, and effective joining make it a candidate for solving many varied and unique bonding tasks.