van Lent, Marlies; Rongen, Gerard A; Out, Henk J
2014-12-10
Submission of study protocols to research ethics committees (RECs) constitutes one of the earliest stages at which planned trials are documented in detail. Previous studies have investigated the amendments requested from researchers by RECs, but the type of issues raised during REC review have not been compared by sponsor type. The objective of this study was to identify recurring shortcomings in protocols of drug trials based on REC comments and to assess whether these were more common among industry-sponsored or non-industry trials. Retrospective analysis of 226 protocols of drug trials approved in 2010-2011 by three RECs affiliated to academic medical centres in The Netherlands. For each protocol, information on sponsorship, number of participating centres, participating countries, study phase, registration status of the study drug, and type and number of subjects was retrieved. REC comments were extracted from decision letters sent to investigators after review and were classified using a predefined checklist that was based on legislation and guidelines on clinical drug research and previous literature. Most protocols received comments regarding participant information and consent forms (n = 182, 80.5%), methodology and statistical analyses (n = 160, 70.8%), and supporting documentation, including trial agreements and certificates of insurance (n = 154, 68.1%). Of the submitted protocols, 122 (54.0%) were non-industry and 104 (46.0%) were industry-sponsored trials. Non-industry trials more often received comments on subject selection (n = 44, 36.1%) than industry-sponsored trials (n = 18, 17.3%; RR, 1.58; 95% CI, 1.01 to 2.47), and on methodology and statistical analyses (n = 95, 77.9% versus n = 65, 62.5%, respectively; RR, 1.18; 95% CI, 1.01 to 1.37). Non-industry trials less often received comments on supporting documentation (n = 72, 59.0%) than industry-sponsored trials (n = 82, 78.8%; RR, 0.83; 95% CI, 0.72 to 0.95). RECs identified important ethical and methodological shortcomings in protocols of both industry-sponsored and non-industry drug trials. Investigators, especially of non-industry trials, should better prepare their research protocols in order to facilitate the ethical review process.
Data exchange technology based on handshake protocol for industrial automation system
NASA Astrophysics Data System (ADS)
Astafiev, A. V.; Shardin, T. O.
2018-05-01
In the article, questions of data exchange technology based on the handshake protocol for industrial automation system are considered. The methods of organizing the technology in client-server applications are analyzed. In the process of work, the main threats of client-server applications that arise during the information interaction of users are indicated. Also, a comparative analysis of analogue systems was carried out, as a result of which the most suitable option was chosen for further use. The basic schemes for the operation of the handshake protocol are shown, as well as the general scheme of the implemented application, which describes the entire process of interaction between the client and the server.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W; Gowans, Dakers; Telarico, Chad
The Commercial and Industrial Lighting Evaluation Protocol (the protocol) describes methods to account for gross energy savings resulting from the programmatic installation of efficient lighting equipment in large populations of commercial, industrial, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. A separate Uniform Methods Project (UMP) protocol, Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol, addresses methods for evaluating savings resulting from lighting control measures such as adding time clocks, tuning energy management system commands, and adding occupancy sensors.
Ghost Authorship in Industry-Initiated Randomised Trials
Gøtzsche, Peter C; Hróbjartsson, Asbjørn; Johansen, Helle Krogh; Haahr, Mette T; Altman, Douglas G; Chan, An-Wen
2007-01-01
Background Ghost authorship, the failure to name, as an author, an individual who has made substantial contributions to an article, may result in lack of accountability. The prevalence and nature of ghost authorship in industry-initiated randomised trials is not known. Methods and Findings We conducted a cohort study comparing protocols and corresponding publications for industry-initiated trials approved by the Scientific-Ethical Committees for Copenhagen and Frederiksberg in 1994–1995. We defined ghost authorship as present if individuals who wrote the trial protocol, performed the statistical analyses, or wrote the manuscript, were not listed as authors of the publication, or as members of a study group or writing committee, or in an acknowledgment. We identified 44 industry-initiated trials. We did not find any trial protocol or publication that stated explicitly that the clinical study report or the manuscript was to be written or was written by the clinical investigators, and none of the protocols stated that clinical investigators were to be involved with data analysis. We found evidence of ghost authorship for 33 trials (75%; 95% confidence interval 60%–87%). The prevalence of ghost authorship was increased to 91% (40 of 44 articles; 95% confidence interval 78%–98%) when we included cases where a person qualifying for authorship was acknowledged rather than appearing as an author. In 31 trials, the ghost authors we identified were statisticians. It is likely that we have overlooked some ghost authors, as we had very limited information to identify the possible omission of other individuals who would have qualified as authors. Conclusions Ghost authorship in industry-initiated trials is very common. Its prevalence could be considerably reduced, and transparency improved, if existing guidelines were followed, and if protocols were publicly available. PMID:17227134
Ghost authorship in industry-initiated randomised trials.
Gøtzsche, Peter C; Hróbjartsson, Asbjørn; Johansen, Helle Krogh; Haahr, Mette T; Altman, Douglas G; Chan, An-Wen
2007-01-01
Ghost authorship, the failure to name, as an author, an individual who has made substantial contributions to an article, may result in lack of accountability. The prevalence and nature of ghost authorship in industry-initiated randomised trials is not known. We conducted a cohort study comparing protocols and corresponding publications for industry-initiated trials approved by the Scientific-Ethical Committees for Copenhagen and Frederiksberg in 1994-1995. We defined ghost authorship as present if individuals who wrote the trial protocol, performed the statistical analyses, or wrote the manuscript, were not listed as authors of the publication, or as members of a study group or writing committee, or in an acknowledgment. We identified 44 industry-initiated trials. We did not find any trial protocol or publication that stated explicitly that the clinical study report or the manuscript was to be written or was written by the clinical investigators, and none of the protocols stated that clinical investigators were to be involved with data analysis. We found evidence of ghost authorship for 33 trials (75%; 95% confidence interval 60%-87%). The prevalence of ghost authorship was increased to 91% (40 of 44 articles; 95% confidence interval 78%-98%) when we included cases where a person qualifying for authorship was acknowledged rather than appearing as an author. In 31 trials, the ghost authors we identified were statisticians. It is likely that we have overlooked some ghost authors, as we had very limited information to identify the possible omission of other individuals who would have qualified as authors. Ghost authorship in industry-initiated trials is very common. Its prevalence could be considerably reduced, and transparency improved, if existing guidelines were followed, and if protocols were publicly available.
Fuzz Testing of Industrial Network Protocols in Programmable Logic Controllers
2017-12-01
PLCs) are vital components in these cyber-physical systems. The industrial network protocols used to communicate between nodes in a control network...AB/RA) MicroLogix 1100 PLC through its implementation of EtherNet/IP, Common Industrial Protocol (CIP), and Programmable Controller Communication ...Commands (PCCC) communication protocols. This research also examines whether cross-generational vulnerabilities exist in the more advanced AB/RA
Kasenda, Benjamin; von Elm, Erik; You, John J; Blümle, Anette; Tomonaga, Yuki; Saccilotto, Ramon; Amstutz, Alain; Bengough, Theresa; Meerpohl, Joerg J; Stegert, Mihaela; Olu, Kelechi K; Tikkinen, Kari A O; Neumann, Ignacio; Carrasco-Labra, Alonso; Faulhaber, Markus; Mulla, Sohail M; Mertz, Dominik; Akl, Elie A; Bassler, Dirk; Busse, Jason W; Ferreira-González, Ignacio; Lamontagne, Francois; Nordmann, Alain; Gloy, Viktoria; Raatz, Heike; Moja, Lorenzo; Ebrahim, Shanil; Schandelmaier, Stefan; Sun, Xin; Vandvik, Per O; Johnston, Bradley C; Walter, Martin A; Burnand, Bernard; Schwenkglenks, Matthias; Hemkens, Lars G; Bucher, Heiner C; Guyatt, Gordon H; Briel, Matthias
2016-06-01
Little is known about publication agreements between industry and academic investigators in trial protocols and the consistency of these agreements with corresponding statements in publications. We aimed to investigate (i) the existence and types of publication agreements in trial protocols, (ii) the completeness and consistency of the reporting of these agreements in subsequent publications, and (iii) the frequency of co-authorship by industry employees. We used a retrospective cohort of randomized clinical trials (RCTs) based on archived protocols approved by six research ethics committees between 13 January 2000 and 25 November 2003. Only RCTs with industry involvement were eligible. We investigated the documentation of publication agreements in RCT protocols and statements in corresponding journal publications. Of 647 eligible RCT protocols, 456 (70.5%) mentioned an agreement regarding publication of results. Of these 456, 393 (86.2%) documented an industry partner's right to disapprove or at least review proposed manuscripts; 39 (8.6%) agreements were without constraints of publication. The remaining 24 (5.3%) protocols referred to separate agreement documents not accessible to us. Of those 432 protocols with an accessible publication agreement, 268 (62.0%) trials were published. Most agreements documented in the protocol were not reported in the subsequent publication (197/268 [73.5%]). Of 71 agreements reported in publications, 52 (73.2%) were concordant with those documented in the protocol. In 14 of 37 (37.8%) publications in which statements suggested unrestricted publication rights, at least one co-author was an industry employee. In 25 protocol-publication pairs, author statements in publications suggested no constraints, but 18 corresponding protocols documented restricting agreements. Publication agreements constraining academic authors' independence are common. Journal articles seldom report on publication agreements, and, if they do, statements can be discrepant with the trial protocol.
Kasenda, Benjamin; von Elm, Erik; You, John J.; Tomonaga, Yuki; Saccilotto, Ramon; Amstutz, Alain; Bengough, Theresa; Meerpohl, Joerg J.; Stegert, Mihaela; Olu, Kelechi K.; Tikkinen, Kari A. O.; Neumann, Ignacio; Carrasco-Labra, Alonso; Faulhaber, Markus; Mulla, Sohail M.; Mertz, Dominik; Akl, Elie A.; Bassler, Dirk; Busse, Jason W.; Nordmann, Alain; Gloy, Viktoria; Ebrahim, Shanil; Schandelmaier, Stefan; Sun, Xin; Vandvik, Per O.; Johnston, Bradley C.; Walter, Martin A.; Burnand, Bernard; Hemkens, Lars G.; Bucher, Heiner C.; Guyatt, Gordon H.; Briel, Matthias
2016-01-01
Background Little is known about publication agreements between industry and academic investigators in trial protocols and the consistency of these agreements with corresponding statements in publications. We aimed to investigate (i) the existence and types of publication agreements in trial protocols, (ii) the completeness and consistency of the reporting of these agreements in subsequent publications, and (iii) the frequency of co-authorship by industry employees. Methods and Findings We used a retrospective cohort of randomized clinical trials (RCTs) based on archived protocols approved by six research ethics committees between 13 January 2000 and 25 November 2003. Only RCTs with industry involvement were eligible. We investigated the documentation of publication agreements in RCT protocols and statements in corresponding journal publications. Of 647 eligible RCT protocols, 456 (70.5%) mentioned an agreement regarding publication of results. Of these 456, 393 (86.2%) documented an industry partner’s right to disapprove or at least review proposed manuscripts; 39 (8.6%) agreements were without constraints of publication. The remaining 24 (5.3%) protocols referred to separate agreement documents not accessible to us. Of those 432 protocols with an accessible publication agreement, 268 (62.0%) trials were published. Most agreements documented in the protocol were not reported in the subsequent publication (197/268 [73.5%]). Of 71 agreements reported in publications, 52 (73.2%) were concordant with those documented in the protocol. In 14 of 37 (37.8%) publications in which statements suggested unrestricted publication rights, at least one co-author was an industry employee. In 25 protocol-publication pairs, author statements in publications suggested no constraints, but 18 corresponding protocols documented restricting agreements. Conclusions Publication agreements constraining academic authors’ independence are common. Journal articles seldom report on publication agreements, and, if they do, statements can be discrepant with the trial protocol. PMID:27352244
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Carlson, Stephen
This Commercial and Industrial Lighting Controls Evaluation Protocol (the protocol) describes methods to account for energy savings resulting from programmatic installation of lighting control equipment in large populations of commercial, industrial, government, institutional, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. When lighting controls are installed in conjunction with a lighting retrofit project, the lighting control savings must be calculated parametrically with the lighting retrofit project so savings are not double counted.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-03
...] Draft Guidance for Industry on ``Target Animal Safety and Effectiveness Protocol Development and...) entitled ``Target Animal Safety and Effectiveness Protocol Development and Submission.'' The purpose of... Center for Veterinary Medicine (CVM), Office of New Animal Drug Evaluation (ONADE), to reduce the time to...
Di Maio, Dario
2017-01-01
The majority of currently published dispersion protocols of carbon nanotubes rely on techniques that are not scalable to an industrial level. This work shows how to obtain polymer nanocomposites with good mechanical characteristics using multi-walled carbon nanotubes epoxy resins obtained by mechanical mixing only. The mechanical dispersion method illustrated in this work is easily scalable to industrial level. The high shearing force due to the complex field of motion produces a good and reproducible carbon nanotube dispersion. We have tested an industrial epoxy matrix with good baseline mechanical characteristics at different carbon nanotube weight loads. ASTM-derived tensile and compressive tests show an increment in both Young’s modulus and compressive strength compared with the pristine resin from a starting low wt %. Comparative vibration tests show improvement in the damping capacity. The new carbon nanotube enhanced epoxy resin has superior mechanical proprieties compared to the market average competitor, and is among the top products in the bi-components epoxy resins market. The new dispersion method shows significant potential for the industrial use of CNTs in epoxy matrices. PMID:29064400
Giovannelli, Andrea; Di Maio, Dario; Scarpa, Fabrizio
2017-10-24
The majority of currently published dispersion protocols of carbon nanotubes rely on techniques that are not scalable to an industrial level. This work shows how to obtain polymer nanocomposites with good mechanical characteristics using multi-walled carbon nanotubes epoxy resins obtained by mechanical mixing only. The mechanical dispersion method illustrated in this work is easily scalable to industrial level. The high shearing force due to the complex field of motion produces a good and reproducible carbon nanotube dispersion. We have tested an industrial epoxy matrix with good baseline mechanical characteristics at different carbon nanotube weight loads. ASTM-derived tensile and compressive tests show an increment in both Young's modulus and compressive strength compared with the pristine resin from a starting low wt %. Comparative vibration tests show improvement in the damping capacity. The new carbon nanotube enhanced epoxy resin has superior mechanical proprieties compared to the market average competitor, and is among the top products in the bi-components epoxy resins market. The new dispersion method shows significant potential for the industrial use of CNTs in epoxy matrices.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-01
... Effectiveness of a Proposed Rule Change Relating to FINRA Trade Reporting Notice on Price Validation and Price... (``Notice'') that explains the price validation protocol of the FINRA trade reporting facilities and sets... trades by comparing the submitted price against price validation parameters established by FINRA...
Redactions in protocols for drug trials: what industry sponsors concealed.
Marquardsen, Mikkel; Ogden, Michelle; Gøtzsche, Peter C
2018-04-01
Objective To describe the redactions in contemporary protocols for industry-sponsored randomised drug trials with patient relevant outcomes and to evaluate whether there was a legitimate rationale for the redactions. Design Cohort study. Under the Freedom of Information Act, we requested access to trial protocols approved by a research ethics committee in Denmark from October 2012 to March 2013. We received 17 consecutive protocols, which had been redacted before we got them, and nine protocols without redactions. In five additional cases, the companies refused to let the committees give us access, and in three other cases, documents were missing. Participants Not applicable. Setting Not applicable. Main outcome measure Amount and nature of redactions in 22 predefined key protocol variables. Results The redactions were most widespread in those sections of the protocol where there is empirical evidence of substantial problems with the trustworthiness of published drug trials: data analysis, handling of missing data, detection and analysis of adverse events, definition of the outcomes, interim analyses and premature termination of the study, sponsor's access to incoming data while the study is running, ownership to the data and investigators' publication rights. The parts of the text that were redacted differed widely, both between companies and within the same company. Conclusions We could not identify any legitimate rationale for the redactions. The current mistrust in industry-sponsored drug trials can only change if the industry offers unconditional access to its trial protocols and other relevant documents and data.
[Constraints on publication rights in industry-initiated clinical trials--secondary publication].
Gøtzsche, Peter C; Hróbjartsson, Asbjørn; Johansen, Helle Krogh; Haahr, Mette T; Altman, Douglas G; Chan, An-Wen
2006-06-19
In 22 of 44 industry-initiated clinical trial protocols from 1994-95, it was noted that the sponsor either owned the data or needed to approve the manuscript; another 18 protocols had other constraints. Furthermore, in 16 trials, the sponsor had access to accumulating data, and in an additional 16 trials the sponsor could stop the trial at any time, for any reason. These facts were not noted in any of the trial reports. We found similar constraints on publication rights in 44 protocols from 2004. This tight sponsor control over industry-initiated trials should be changed.
Campbell, Eric G; Vogeli, Christine; Rao, Sowmya R; Abraham, Melissa; Pierson, Roz; Applebaum, Sandra
2015-09-01
For the past decade, more attention and concern has been directed toward financial relationships between the life science industry and physicians. Relationships between industry and institutional review board (IRB) members represent an important subclass that has the potential to broadly influence decisions regarding medical research. To study the nature, extent, and perceived consequences of industry relationships among IRB members in academic health centers and to compare our results with findings from 2005. A survey mailed to IRB members from the 115 most research-intensive medical schools and teaching hospitals in the United States from January 16 through May 16, 2014. The survey included questions identical to those used in 2005. Data analysis was conducted from June through October 2014. The frequency of industry relationships among IRB members and the perceived effect of those relationships on IRB-related activities. We found no significant change in the percentage of IRB members with an industry relationship from 2005 through 2014 (2005: 37.2%; 95% CI, 32.7%-42.0%; 2014: 32.1%; 95% CI, 28.0%-36.4%; P = .09). However, since 2005, the percentage of members who felt another member did not properly disclose a financial relationship decreased from 10.8% (95% CI, 8.0%-14.4%) to 6.7% (95% CI, 4.7%-9.4%) (P = .04), as did the percentage who felt pressure from their institution or department to approve a protocol (2005: 18.6%; 95% CI, 15.0%-22.9%; 2014: 10.0%; 95% CI, 7.6%-13.0%; P < .001). The percentage of members with a conflict of interest who voted on protocols with which they have a conflict has not changed, although the percentage who said they always disclose relationships increased significantly from 54.9% in 2005 (95% CI, 42.2%-66.9%) to 80.0% in 2014 (95% CI, 65.3%-89.4%) (P = .01). We also found evidence of anti-industry bias in the presentation of protocols to the IRB. The results show significant positive progress in the reporting and management of conflicts of interest among IRB members in academic health centers since 2005 after adjusting for other factors. Additional attention should be focused on deterring IRB members from inappropriately voting on or presenting protocols in a biased manner.
The need for LWR metrology standardization: the imec roughness protocol
NASA Astrophysics Data System (ADS)
Lorusso, Gian Francesco; Sutani, Takumichi; Rutigliani, Vito; van Roey, Frieda; Moussa, Alain; Charley, Anne-Laure; Mack, Chris; Naulleau, Patrick; Constantoudis, Vassilios; Ikota, Masami; Ishimoto, Toru; Koshihara, Shunsuke
2018-03-01
As semiconductor technology keeps moving forward, undeterred by the many challenges ahead, one specific deliverable is capturing the attention of many experts in the field: Line Width Roughness (LWR) specifications are expected to be less than 2nm in the near term, and to drop below 1nm in just a few years. This is a daunting challenge and engineers throughout the industry are trying to meet these targets using every means at their disposal. However, although current efforts are surely admirable, we believe they are not enough. The fact is that a specification has a meaning only if there is an agreed methodology to verify if the criterion is met or not. Such a standardization is critical in any field of science and technology and the question that we need to ask ourselves today is whether we have a standardized LWR metrology or not. In other words, if a single reference sample were provided, would everyone measuring it get reasonably comparable results? We came to realize that this is not the case and that the observed spread in the results throughout the industry is quite large. In our opinion, this makes the comparison of LWR data among institutions, or to a specification, very difficult. In this paper, we report the spread of measured LWR data across the semiconductor industry. We investigate the impact of image acquisition, measurement algorithm, and frequency analysis parameters on LWR metrology. We review critically some of the International Technology Roadmap for Semiconductors (ITRS) metrology guidelines (such as measurement box length larger than 2μm and the need to correct for SEM noise). We compare the SEM roughness results to AFM measurements. Finally, we propose a standardized LWR measurement protocol - the imec Roughness Protocol (iRP) - intended to ensure that every time LWR measurements are compared (from various sources or to specifications), the comparison is sensible and sound. We deeply believe that the industry is at a point where it is imperative to guarantee that when talking about a critical parameter such like LWR, everyone speaks the same language, which is not currently the case.
Planning and reporting of quality-of-life outcomes in cancer trials
Schandelmaier, S.; Conen, K.; von Elm, E.; You, J. J.; Blümle, A.; Tomonaga, Y.; Amstutz, A.; Briel, M.; Kasenda, B.
2015-01-01
Background Information about the impact of cancer treatments on patients' quality of life (QoL) is of paramount importance to patients and treating oncologists. Cancer trials that do not specify QoL as an outcome or fail to report collected QoL data, omit crucial information for decision making. To estimate the magnitude of these problems, we investigated how frequently QoL outcomes were specified in protocols of cancer trials and subsequently reported. Design Retrospective cohort study of RCT protocols approved by six research ethics committees in Switzerland, Germany, and Canada between 2000 and 2003. We compared protocols to corresponding publications, which were identified through literature searches and investigator surveys. Results Of the 173 cancer trials, 90 (52%) specified QoL outcomes in their protocol, 2 (1%) as primary and 88 (51%) as secondary outcome. Of the 173 trials, 35 (20%) reported QoL outcomes in a corresponding publication (4 modified from the protocol), 18 (10%) were published but failed to report QoL outcomes in the primary or a secondary publication, and 37 (21%) were not published at all. Of the 83 (48%) trials that did not specify QoL outcomes in their protocol, none subsequently reported QoL outcomes. Failure to report pre-specified QoL outcomes was not associated with industry sponsorship (versus non-industry), sample size, and multicentre (versus single centre) status but possibly with trial discontinuation. Conclusions About half of cancer trials specified QoL outcomes in their protocols. However, only 20% reported any QoL data in associated publications. Highly relevant information for decision making is often unavailable to patients, oncologists, and health policymakers. PMID:26133966
Economic Crisis and Inequality of Educational Opportunity in Latin America
ERIC Educational Resources Information Center
Torche, Florencia
2010-01-01
Research in the industrialized world shows that the influence of family background on educational attainment has remained stable or declined over time. In contrast, very little is known about the developing world. Using high-quality data sets and a standard protocol, this article offers a comparative analysis of trends in educational…
COSPO/CENDI Industry Day Conference
NASA Technical Reports Server (NTRS)
1995-01-01
The conference's objective was to provide a forum where government information managers and industry information technology experts could have an open exchange and discuss their respective needs and compare them to the available, or soon to be available, solutions. Technical summaries and points of contact are provided for the following sessions: secure products, protocols, and encryption; information providers; electronic document management and publishing; information indexing, discovery, and retrieval (IIDR); automated language translators; IIDR - natural language capabilities; IIDR - advanced technologies; IIDR - distributed heterogeneous and large database support; and communications - speed, bandwidth, and wireless.
The Activity of Antimicrobial Surfaces Varies by Testing Protocol Utilized
Campos, Matias D.; Zucchi, Paola C.; Phung, Ann; Leonard, Steven N.; Hirsch, Elizabeth B.
2016-01-01
Background Contaminated hospital surfaces are an important source of nosocomial infections. A major obstacle in marketing antimicrobial surfaces is a lack of efficacy data based on standardized testing protocols. Aim We compared the efficacy of multiple testing protocols against several “antimicrobial” film surfaces. Methods Four clinical isolates were used: one Escherichia coli, one Klebsiella pneumoniae, and two Staphylococcus aureus strains. Two industry methods (modified ISO 22196 and ASTM E2149), a “dried droplet”, and a “transfer” method were tested against two commercially available antimicrobial films, one film in development, an untreated control, and a positive (silver) control film. At 2 (only ISO) and 24 hours following inoculation, bacteria were collected from film surfaces and enumerated. Results Compared to untreated films in all protocols, there were no significant differences in recovery on either commercial brand at 2 or 24 hours after inoculation. The silver surface demonstrated significant microbicidal activity (mean loss 4.9 Log10 CFU/ml) in all methods and time points with the exception of 2 hours in the ISO protocol and the transfer method. Using our novel droplet method, no differences between placebo and active surfaces were detected. The surface in development demonstrated variable activity depending on method, organism, and time point. The ISO demonstrated minimal activity at 2 hours but significant activity at 24 hours (mean 4.5 Log10 CFU/ml difference versus placebo). The ASTEM protocol exhibited significant differences in recovery of staphylococci (mean 5 Log10 CFU/ml) but not Gram-negative isolates (10 fold decrease). Minimal activity was observed with this film in the transfer method. Conclusions Varying results between protocols suggested that efficacy of antimicrobial surfaces cannot be easily and reproducibly compared. Clinical use should be considered and further development of representative methods is needed. PMID:27494336
Development of Uniform Protocol for Alopecia Areata Clinical Trials.
Solomon, James A
2015-11-01
Developing a successful treatment for alopecia areata (AA), clearly has not been at the forefront of the agenda for new drug/device development among the pharmaceutical and medical device industry. The National Alopecia Areata Foundation (NAAF), a patient advocacy group, initiated a plan to facilitate and drive clinical research toward finding safe and efficacious treatments for AA. As such, Alopecia Areata Uniform Protocols for clinical trials to test new treatments for AA were developed. The design of the uniform protocol is to accomplish the development of a plug-and-play template as well as to provide a framework wherein data from studies utilizing the uniform protocol can be compared through consistency of inclusions/exclusions, safety, and outcome assessment measures. A core uniform protocol for use by pharmaceutical companies in testing proof of concept for investigational products to treat AA. The core protocol includes standardized title, informed consent, inclusion/exclusion criteria, disease outcome assessments, and safety assessments. The statistical methodology to assess successful outcomes will also be standardized. The protocol as well as the informed consent form has been approved in concept by Liberty IRB and is ready to present to pharmaceutical companies.
NASA Astrophysics Data System (ADS)
Shpenst, V. A.; Vasiliev, B. Y.; Kalashnikov, O. V.; Oleynikova, A. M.
2018-05-01
The article covers a consideration of various state-of-the-art industrial data transfer protocols, e.g. Modbus, Profibus, Industrial Ethernet and CAN. Their pros and cons are analyzed and conclusions made on advisability of the use of each protocol. It is shown that for the arrangement of effective telecommunication interaction of microprocessor devices of different types in the composition of multi-motor electric drives, it is advisable to use highlevel CAN-protocols, such as CANopen and DeviceNet.
A review of tags anti-collision and localization protocols in RFID networks.
Ullah, S; Alsalih, W; Alsehaim, A; Alsadhan, N
2012-12-01
Radio Frequency IDentification (RFID) has allowed the realization of ubiquitous tracking and monitoring of physical objects wirelessly with minimum human interactions. It plays a key role in a wide range of applications including asset tracking, contactless payment, access control, transportation and logistics, and other industrial applications. On the other side, RFID systems face several technical challenges that need to be overcome in order to achieve their potential benefits; tags collisions and localization of tagged objects are two important challenges. Numerous anti-collision and localization protocols have been proposed to address these challenges. This paper reviews the state-of-art tags' anti-collision and localization protocols, and provides a deep insight into technical issues of these protocols. The probabilistic and deterministic anti-collision protocols are critically studied and compared in terms of different parameters. We further review distance estimation, scene analysis, and proximity localization schemes and provide useful suggestions. We also introduce a new hybrid direction that utilizes power control to spatially partition the interrogation range of a reader for more efficient anti-collision and localization. Finally, we present the applications of RFID systems in healthcare sectors.
Relative risk analysis of several manufactured nanomaterials: an insurance industry context.
Robichaud, Christine Ogilvie; Tanzil, Dicksen; Weilenmann, Ulrich; Wiesner, Mark R
2005-11-15
A relative risk assessment is presented for the industrial fabrication of several nanomaterials. The production processes for five nanomaterials were selected for this analysis, based on their current or near-term potential for large-scale production and commercialization: single-walled carbon nanotubes, bucky balls (C60), one variety of quantum dots, alumoxane nanoparticles, and nano-titanium dioxide. The assessment focused on the activities surrounding the fabrication of nanomaterials, exclusive of any impacts or risks with the nanomaterials themselves. A representative synthesis method was selected for each nanomaterial based on its potential for scaleup. A list of input materials, output materials, and waste streams for each step of fabrication was developed and entered into a database that included key process characteristics such as temperature and pressure. The physical-chemical properties and quantities of the inventoried materials were used to assess relative risk based on factors such as volatility, carcinogenicity, flammability, toxicity, and persistence. These factors were first used to qualitatively rank risk, then combined using an actuarial protocol developed by the insurance industry for the purpose of calculating insurance premiums for chemical manufacturers. This protocol ranks three categories of risk relative to a 100 point scale (where 100 represents maximum risk): incident risk, normal operations risk, and latent contamination risk. Results from this analysis determined that relative environmental risk from manufacturing each of these five materials was comparatively low in relation to other common industrial manufacturing processes.
Dynamic gastric digestion of a commercial whey protein concentrate†.
Miralles, Beatriz; Del Barrio, Roberto; Cueva, Carolina; Recio, Isidra; Amigo, Lourdes
2018-03-01
A dynamic gastrointestinal simulator, simgi ® , has been applied to assess the gastric digestion of a whey protein concentrate. Samples collected from the outlet of the stomach have been compared to those resulting from the static digestion protocol INFOGEST developed on the basis of physiologically inferred conditions. Progress of digestion was followed by SDS-PAGE and LC-MS/MS. By SDS-PAGE, serum albumin and α-lactalbumin were no longer detectable at 30 and 60 min, respectively. On the contrary, β-lactoglobulin was visible up to 120 min, although in decreasing concentrations in the dynamic model due to the gastric emptying and the addition of gastric fluids. Moreover, β-lactoglobulin was partly hydrolysed by pepsin probably due to the presence of heat-denatured forms and the peptides released using both digestion models were similar. Under dynamic conditions, a stepwise increase in number of peptides over time was observed, while the static protocol generated a high number of peptides from the beginning of digestion. Whey protein digestion products using a dynamic stomach are consistent with those generated with the static protocol but the kinetic behaviour of the peptide profile emphasises the effect of the sequential pepsin addition, peristaltic shaking, and gastric emptying on protein digestibility. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Space Wire Upper Layer Protocols
NASA Technical Reports Server (NTRS)
Rakow, Glenn; Schnurr, Richard; Gilley, Daniel; Parkes, Steve
2004-01-01
This viewgraph presentation addresses efforts to provide a streamlined approach for developing SpaceWire Upper layer protocols which allows industry to drive standardized communication solutions for real projects. The presentation proposes a simple packet header that will allow flexibility in implementing a diverse range of protocols.
Rudolph, Jürn; Bruckmaier, Rupert M; Kasimanickam, Ramanathan; Steiner, Adrian; Kirchhofer, Marc; Hüsler, Jürg; Hirsbrunner, Gaby
2011-11-25
Synchronization programs have become standard in the dairy industry in many countries. In Switzerland, these programs are not routinely used for groups of cows, but predominantly as a therapy for individual problem cows. The objective of this study was to compare the effect of a CIDR-Select Synch and a 12-d CIDR protocol on the pregnancy rate in healthy, multiparous dairy cows in Swiss dairy farms. Cows (N = 508) were randomly assigned to CIDR-Select Synch (N = 262) or 12-d CIDR (N = 246) protocols. Cows in the CIDR-Select Synch group received a CIDR and 2.5 ml of buserelin i.m. on d 0. On d 7, the CIDR insert was removed and 5 ml of dinoprost was administered i.m.. Cows in the 12-d CIDR group received the CIDR on d 0 and it was removed on d 12 (the routine CIDR protocol in Swiss dairies). On d 0 a milk sample for progesterone analysis was taken. Cows were inseminated upon observed estrus. Pregnancy was determined at or more than 35 days after artificial insemination. As a first step, the two groups were compared as to indication for treatment, breed, stud book, stall, pasture, and farmer's business using chi square tests or Fisher's exact test. Furthermore, groups were compared as to age, DIM, number of AI's, number of cows per farm, and yearly milk yield per cow using nonparametric ANOVA. A multiple logistic model was used to relate the success of the protocols to all of the available factors; in particular treatment (CIDR-Select Synch/12-d CIDR), milk progesterone value, age, DIM, previous treatment of the uterus, previous gynecological treatment, and number of preceding inseminations. The pregnancy rate was higher in cows following the CIDR-Select Synch compared to the 12-d CIDR protocol (50.4% vs. 22.4%; P < 0.0001). The CIDR-Select Synch protocol may be highly recommended for multiparous dairy cows. The reduced time span of the progesterone insert decreased the number of days open, improved the pregnancy rate compared to the 12-d CIDR protocol and the cows did not to have to be handled more often.
2011-01-01
Background Synchronization programs have become standard in the dairy industry in many countries. In Switzerland, these programs are not routinely used for groups of cows, but predominantly as a therapy for individual problem cows. The objective of this study was to compare the effect of a CIDR-Select Synch and a 12-d CIDR protocol on the pregnancy rate in healthy, multiparous dairy cows in Swiss dairy farms. Methods Cows (N = 508) were randomly assigned to CIDR-Select Synch (N = 262) or 12-d CIDR (N = 246) protocols. Cows in the CIDR-Select Synch group received a CIDR and 2.5 ml of buserelin i.m. on d 0. On d 7, the CIDR insert was removed and 5 ml of dinoprost was administered i.m.. Cows in the 12-d CIDR group received the CIDR on d 0 and it was removed on d 12 (the routine CIDR protocol in Swiss dairies). On d 0 a milk sample for progesterone analysis was taken. Cows were inseminated upon observed estrus. Pregnancy was determined at or more than 35 days after artificial insemination. As a first step, the two groups were compared as to indication for treatment, breed, stud book, stall, pasture, and farmer's business using chi square tests or Fisher's exact test. Furthermore, groups were compared as to age, DIM, number of AI's, number of cows per farm, and yearly milk yield per cow using nonparametric ANOVA. A multiple logistic model was used to relate the success of the protocols to all of the available factors; in particular treatment (CIDR-Select Synch/12-d CIDR), milk progesterone value, age, DIM, previous treatment of the uterus, previous gynecological treatment, and number of preceding inseminations. Results The pregnancy rate was higher in cows following the CIDR-Select Synch compared to the 12-d CIDR protocol (50.4% vs. 22.4%; P < 0.0001). Conclusion The CIDR-Select Synch protocol may be highly recommended for multiparous dairy cows. The reduced time span of the progesterone insert decreased the number of days open, improved the pregnancy rate compared to the 12-d CIDR protocol and the cows did not to have to be handled more often. PMID:22117599
In silico toxicology protocols.
Myatt, Glenn J; Ahlberg, Ernst; Akahori, Yumi; Allen, David; Amberg, Alexander; Anger, Lennart T; Aptula, Aynur; Auerbach, Scott; Beilke, Lisa; Bellion, Phillip; Benigni, Romualdo; Bercu, Joel; Booth, Ewan D; Bower, Dave; Brigo, Alessandro; Burden, Natalie; Cammerer, Zoryana; Cronin, Mark T D; Cross, Kevin P; Custer, Laura; Dettwiler, Magdalena; Dobo, Krista; Ford, Kevin A; Fortin, Marie C; Gad-McDonald, Samantha E; Gellatly, Nichola; Gervais, Véronique; Glover, Kyle P; Glowienke, Susanne; Van Gompel, Jacky; Gutsell, Steve; Hardy, Barry; Harvey, James S; Hillegass, Jedd; Honma, Masamitsu; Hsieh, Jui-Hua; Hsu, Chia-Wen; Hughes, Kathy; Johnson, Candice; Jolly, Robert; Jones, David; Kemper, Ray; Kenyon, Michelle O; Kim, Marlene T; Kruhlak, Naomi L; Kulkarni, Sunil A; Kümmerer, Klaus; Leavitt, Penny; Majer, Bernhard; Masten, Scott; Miller, Scott; Moser, Janet; Mumtaz, Moiz; Muster, Wolfgang; Neilson, Louise; Oprea, Tudor I; Patlewicz, Grace; Paulino, Alexandre; Lo Piparo, Elena; Powley, Mark; Quigley, Donald P; Reddy, M Vijayaraj; Richarz, Andrea-Nicole; Ruiz, Patricia; Schilter, Benoit; Serafimova, Rositsa; Simpson, Wendy; Stavitskaya, Lidiya; Stidl, Reinhard; Suarez-Rodriguez, Diana; Szabo, David T; Teasdale, Andrew; Trejo-Martin, Alejandra; Valentin, Jean-Pierre; Vuorinen, Anna; Wall, Brian A; Watts, Pete; White, Angela T; Wichard, Joerg; Witt, Kristine L; Woolley, Adam; Woolley, David; Zwickl, Craig; Hasselgren, Catrin
2018-07-01
The present publication surveys several applications of in silico (i.e., computational) toxicology approaches across different industries and institutions. It highlights the need to develop standardized protocols when conducting toxicity-related predictions. This contribution articulates the information needed for protocols to support in silico predictions for major toxicological endpoints of concern (e.g., genetic toxicity, carcinogenicity, acute toxicity, reproductive toxicity, developmental toxicity) across several industries and regulatory bodies. Such novel in silico toxicology (IST) protocols, when fully developed and implemented, will ensure in silico toxicological assessments are performed and evaluated in a consistent, reproducible, and well-documented manner across industries and regulatory bodies to support wider uptake and acceptance of the approaches. The development of IST protocols is an initiative developed through a collaboration among an international consortium to reflect the state-of-the-art in in silico toxicology for hazard identification and characterization. A general outline for describing the development of such protocols is included and it is based on in silico predictions and/or available experimental data for a defined series of relevant toxicological effects or mechanisms. The publication presents a novel approach for determining the reliability of in silico predictions alongside experimental data. In addition, we discuss how to determine the level of confidence in the assessment based on the relevance and reliability of the information. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
48 CFR 204.470 - U.S.-International Atomic Energy Agency Additional Protocol.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false U.S.-International Atomic Energy Agency Additional Protocol. 204.470 Section 204.470 Federal Acquisition Regulations System DEFENSE... Information Within Industry 204.470 U.S.-International Atomic Energy Agency Additional Protocol. ...
48 CFR 204.470 - U.S.-International Atomic Energy Agency Additional Protocol.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false U.S.-International Atomic Energy Agency Additional Protocol. 204.470 Section 204.470 Federal Acquisition Regulations System DEFENSE... Information Within Industry 204.470 U.S.-International Atomic Energy Agency Additional Protocol. ...
48 CFR 204.470 - U.S.-International Atomic Energy Agency Additional Protocol.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false U.S.-International Atomic Energy Agency Additional Protocol. 204.470 Section 204.470 Federal Acquisition Regulations System DEFENSE... Information Within Industry 204.470 U.S.-International Atomic Energy Agency Additional Protocol. ...
48 CFR 204.470 - U.S.-International Atomic Energy Agency Additional Protocol.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false U.S.-International Atomic Energy Agency Additional Protocol. 204.470 Section 204.470 Federal Acquisition Regulations System DEFENSE... Information Within Industry 204.470 U.S.-International Atomic Energy Agency Additional Protocol. ...
48 CFR 204.470 - U.S.-International Atomic Energy Agency Additional Protocol.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false U.S.-International Atomic Energy Agency Additional Protocol. 204.470 Section 204.470 Federal Acquisition Regulations System DEFENSE... Information Within Industry 204.470 U.S.-International Atomic Energy Agency Additional Protocol. ...
15 CFR 781.2 - Purposes of the Additional Protocol and APR.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL... and less any information to which the U.S. Government applies the national security exclusion, is... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Purposes of the Additional Protocol...
Access Protocol For An Industrial Optical Fibre LAN
NASA Astrophysics Data System (ADS)
Senior, John M.; Walker, William M.; Ryley, Alan
1987-09-01
A structure for OSI levels 1 and 2 of a local area network suitable for use in a variety of industrial environments is reported. It is intended that the LAN will utilise optical fibre technology at the physical level and a hybrid of dynamically optimisable token passing and CSMA/CD techniques at the data link (IEEE 802 medium access control - logical link control) level. An intelligent token passing algorithm is employed which dynamically allocates tokens according to the known upper limits on the requirements of each device. In addition a system of stochastic tokens is used to increase efficiency when the stochastic traffic is significant. The protocol also allows user-defined priority systems to be employed and is suitable for distributed or centralised implementation. The results of computer simulated performance characteristics for the protocol using a star-ring topology are reported which demonstrate its ability to perform efficiently with the device and traffic loads anticipated within an industrial environment.
Detterbeck, Andreas; Hofmeister, Michael; Hofmann, Elisabeth; Haddad, Daniel; Weber, Daniel; Hölzing, Astrid; Zabler, Simon; Schmid, Matthias; Hiller, Karl-Heinz; Jakob, Peter; Engel, Jens; Hiller, Jochen; Hirschfelder, Ursula
2016-07-01
To examine the relative usefulness and suitability of magnetic resonance imaging (MRI) in daily clinical practice as compared to various technologies of computed tomography (CT) in addressing questions of orthodontic interest. Three blinded raters evaluated 2D slices and 3D reconstructions created from scans of two pig heads. Five imaging modalities were used, including three CT technologies-multislice (MSCT), cone-beam CT (CBCT), and industrial (µCT)-and two MRI protocols with different scan durations. Defined orthodontic parameters were rated one by one on the 2D slices and the 3D reconstructions, followed by final overall ratings for each modality. A mixed linear model was used for statistical analysis. Based on the 2D slices, the parameter of visualizing tooth-germ topography did not yield any significantly different ratings for MRI versus any of the CT scans. While some ratings for the other parameters did involve significant differences, how these should be interpreted depends greatly on the relevance of each parameter. Based on the 3D reconstructions, the only significant difference between technologies was noted for the parameter of visualizing root-surface morphology. Based on the final overall ratings, the imaging performance of the standard MRI protocol was noninferior to the performance of the three CT technologies. On comparing the imaging performance of MRI and CT scans, it becomes clear that MRI has a huge potential for applications in daily clinical practice. Given its additional benefits of a good contrast ratio and complete absence of ionizing radiation, further studies are needed to explore this clinical potential in greater detail.
Kasenda, Benjamin; Schandelmaier, Stefan; Sun, Xin; von Elm, Erik; You, John; Blümle, Anette; Tomonaga, Yuki; Saccilotto, Ramon; Amstutz, Alain; Bengough, Theresa; Meerpohl, Joerg J; Stegert, Mihaela; Olu, Kelechi K; Tikkinen, Kari A O; Neumann, Ignacio; Carrasco-Labra, Alonso; Faulhaber, Markus; Mulla, Sohail M; Mertz, Dominik; Akl, Elie A; Bassler, Dirk; Busse, Jason W; Ferreira-González, Ignacio; Lamontagne, Francois; Nordmann, Alain; Gloy, Viktoria; Raatz, Heike; Moja, Lorenzo; Rosenthal, Rachel; Ebrahim, Shanil; Vandvik, Per O; Johnston, Bradley C; Walter, Martin A; Burnand, Bernard; Schwenkglenks, Matthias; Hemkens, Lars G; Bucher, Heiner C; Guyatt, Gordon H; Briel, Matthias
2014-07-16
To investigate the planning of subgroup analyses in protocols of randomised controlled trials and the agreement with corresponding full journal publications. Cohort of protocols of randomised controlled trial and subsequent full journal publications. Six research ethics committees in Switzerland, Germany, and Canada. 894 protocols of randomised controlled trial involving patients approved by participating research ethics committees between 2000 and 2003 and 515 subsequent full journal publications. Of 894 protocols of randomised controlled trials, 252 (28.2%) included one or more planned subgroup analyses. Of those, 17 (6.7%) provided a clear hypothesis for at least one subgroup analysis, 10 (4.0%) anticipated the direction of a subgroup effect, and 87 (34.5%) planned a statistical test for interaction. Industry sponsored trials more often planned subgroup analyses compared with investigator sponsored trials (195/551 (35.4%) v 57/343 (16.6%), P<0.001). Of 515 identified journal publications, 246 (47.8%) reported at least one subgroup analysis. In 81 (32.9%) of the 246 publications reporting subgroup analyses, authors stated that subgroup analyses were prespecified, but this was not supported by 28 (34.6%) corresponding protocols. In 86 publications, authors claimed a subgroup effect, but only 36 (41.9%) corresponding protocols reported a planned subgroup analysis. Subgroup analyses are insufficiently described in the protocols of randomised controlled trials submitted to research ethics committees, and investigators rarely specify the anticipated direction of subgroup effects. More than one third of statements in publications of randomised controlled trials about subgroup prespecification had no documentation in the corresponding protocols. Definitive judgments regarding credibility of claimed subgroup effects are not possible without access to protocols and analysis plans of randomised controlled trials. © The DISCO study group 2014.
2015-09-17
network intrusion detection systems NIST National Institute of Standards and Technology p-tree protocol tree PI protocol informatics PLC programmable logic...electrical, water, oil , natural gas, manufacturing, and pharmaceutical industries, to name a few. The differences between SCADA and DCS systems are often... Oil Company, also known as Saudi Aramco, suffered huge data loss that resulted in the disruption of daily operations for nearly two weeks [BTR13]. As it
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W; Benton, Nathanael; Burns, Patrick
Compressed-air systems are used widely throughout industry for many operations, including pneumatic tools, packaging and automation equipment, conveyors, and other industrial process operations. Compressed-air systems are defined as a group of subsystems composed of air compressors, air treatment equipment, controls, piping, pneumatic tools, pneumatically powered machinery, and process applications using compressed air. A compressed-air system has three primary functional subsystems: supply, distribution, and demand. Air compressors are the primary energy consumers in a compressed-air system and are the primary focus of this protocol. The two compressed-air energy efficiency measures specifically addressed in this protocol are: High-efficiency/variable speed drive (VSD) compressormore » replacing modulating, load/unload, or constant-speed compressor; and Compressed-air leak survey and repairs. This protocol provides direction on how to reliably verify savings from these two measures using a consistent approach for each.« less
Castro, Luis A; Favela, Jesus; Garcia-Peña, Carmen
2014-11-01
The transition from paper to electronic-based records in the healthcare industry has posed several challenges to conventional medical practices. The introduction of technology in day-to-day medical and nursing practices deserves careful consideration. In this work, we report the results of a controlled experiment to compare nurses' consultation in emergency calls in six different conditions. We studied the effect that the type of communication media (face-to-face, telephone, videoconference) and type of nursing protocol media (paper-based, electronic-based) can have on consultation time, mistakes made, pauses during consultation, eye contact, and efficacy of the consultation. We found that the type of communication media has an effect on consultation time; on average, fewer mistakes were made during telephone-based consultations; for eye contact, there were significantly fewer eye contacts during face-to-face than during videoconference consultations; finally, the type of communication media or protocol media did not have any effect in the efficacy of the consultation.
McClements, Jake; McClements, David Julian
2016-06-10
There has been a rapid increase in the fabrication of various kinds of edible nanoparticles for oral delivery of bioactive agents, such as those constructed from proteins, carbohydrates, lipids, and/or minerals. It is currently difficult to compare the relative advantages and disadvantages of different kinds of nanoparticle-based delivery systems because researchers use different analytical instruments and protocols to characterize them. In this paper, we briefly review the various analytical methods available for characterizing the properties of edible nanoparticles, such as composition, morphology, size, charge, physical state, and stability. This information is then used to propose a number of standardized protocols for characterizing nanoparticle properties, for evaluating their stability to environmental stresses, and for predicting their biological fate. Implementation of these protocols would facilitate comparison of the performance of nanoparticles under standardized conditions, which would facilitate the rational selection of nanoparticle-based delivery systems for different applications in the food, health care, and pharmaceutical industries.
2014-12-01
Government . IRB Protocol number ____N/A____. 12a. DISTRIBUTION / AVAILABILITY STATEMENT Approved for public release; distribution is unlimited...control many of the major industries. Jamaica is also a free-market economy, but the government takes a fairly active role in attracting business to the...Polanyi countered Smith’s idea that markets arose spontaneously. Polanyi argued that governments create markets and direct and regulate them to protect
Shahzad, Aamir; Landry, René; Lee, Malrey; Xiong, Naixue; Lee, Jongho; Lee, Changhoon
2016-01-01
Substantial changes have occurred in the Information Technology (IT) sectors and with these changes, the demand for remote access to field sensor information has increased. This allows visualization, monitoring, and control through various electronic devices, such as laptops, tablets, i-Pads, PCs, and cellular phones. The smart phone is considered as a more reliable, faster and efficient device to access and monitor industrial systems and their corresponding information interfaces anywhere and anytime. This study describes the deployment of a protocol whereby industrial system information can be securely accessed by cellular phones via a Supervisory Control And Data Acquisition (SCADA) server. To achieve the study goals, proprietary protocol interconnectivity with non-proprietary protocols and the usage of interconnectivity services are considered in detail. They support the visualization of the SCADA system information, and the related operations through smart phones. The intelligent sensors are configured and designated to process real information via cellular phones by employing information exchange services between the proprietary protocol and non-proprietary protocols. SCADA cellular access raises the issue of security flaws. For these challenges, a cryptography-based security method is considered and deployed, and it could be considered as a part of a proprietary protocol. Subsequently, transmission flows from the smart phones through a cellular network. PMID:27314351
Shahzad, Aamir; Landry, René; Lee, Malrey; Xiong, Naixue; Lee, Jongho; Lee, Changhoon
2016-06-14
Substantial changes have occurred in the Information Technology (IT) sectors and with these changes, the demand for remote access to field sensor information has increased. This allows visualization, monitoring, and control through various electronic devices, such as laptops, tablets, i-Pads, PCs, and cellular phones. The smart phone is considered as a more reliable, faster and efficient device to access and monitor industrial systems and their corresponding information interfaces anywhere and anytime. This study describes the deployment of a protocol whereby industrial system information can be securely accessed by cellular phones via a Supervisory Control And Data Acquisition (SCADA) server. To achieve the study goals, proprietary protocol interconnectivity with non-proprietary protocols and the usage of interconnectivity services are considered in detail. They support the visualization of the SCADA system information, and the related operations through smart phones. The intelligent sensors are configured and designated to process real information via cellular phones by employing information exchange services between the proprietary protocol and non-proprietary protocols. SCADA cellular access raises the issue of security flaws. For these challenges, a cryptography-based security method is considered and deployed, and it could be considered as a part of a proprietary protocol. Subsequently, transmission flows from the smart phones through a cellular network.
Industrial WSN Based on IR-UWB and a Low-Latency MAC Protocol
NASA Astrophysics Data System (ADS)
Reinhold, Rafael; Underberg, Lisa; Wulf, Armin; Kays, Ruediger
2016-07-01
Wireless sensor networks for industrial communication require high reliability and low latency. As current wireless sensor networks do not entirely meet these requirements, novel system approaches need to be developed. Since ultra wideband communication systems seem to be a promising approach, this paper evaluates the performance of the IEEE 802.15.4 impulse-radio ultra-wideband physical layer and the IEEE 802.15.4 Low Latency Deterministic Network (LLDN) MAC for industrial applications. Novel approaches and system adaptions are proposed to meet the application requirements. In this regard, a synchronization approach based on circular average magnitude difference functions (CAMDF) and on a clean template (CT) is presented for the correlation receiver. An adapted MAC protocol titled aggregated low latency (ALL) MAC is proposed to significantly reduce the resulting latency. Based on the system proposals, a hardware prototype has been developed, which proves the feasibility of the system and visualizes the real-time performance of the MAC protocol.
Khan, Anwar; Ali, Ihsan; Ghani, Abdullah; Khan, Nawsher; Alsaqer, Mohammed; Rahman, Atiq Ur; Mahmood, Hasan
2018-05-18
Recent research in underwater wireless sensor networks (UWSNs) has gained the attention of researchers in academia and industry for a number of applications. They include disaster and earthquake prediction, water quality and environment monitoring, leakage and mine detection, military surveillance and underwater navigation. However, the aquatic medium is associated with a number of limitations and challenges: long multipath delay, high interference and noise, harsh environment, low bandwidth and limited battery life of the sensor nodes. These challenges demand research techniques and strategies to be overcome in an efficient and effective fashion. The design of routing protocols for UWSNs is one of the promising solutions to cope with these challenges. This paper presents a survey of the routing protocols for UWSNs. For the ease of description, the addressed routing protocols are classified into two groups: localization-based and localization-free protocols. These groups are further subdivided according to the problems they address or the major parameters they consider during routing. Unlike the existing surveys, this survey considers only the latest and state-of-the-art routing protocols. In addition, every protocol is described in terms of its routing strategy and the problem it addresses and solves. The merit(s) of each protocol is (are) highlighted along with the cost. A description of the protocols in this fashion has a number of advantages for researchers, as compared to the existing surveys. Firstly, the description of the routing strategy of each protocol makes its routing operation easily understandable. Secondly, the demerit(s) of a protocol provides (provide) insight into overcoming its flaw(s) in future investigation. This, in turn, leads to the foundation of new protocols that are more intelligent, robust and efficient with respect to the desired parameters. Thirdly, a protocol can be selected for the appropriate application based on its described merit(s). Finally, open challenges and research directions are presented for future investigation.
Ghani, Abdullah; Alsaqer, Mohammed; Rahman, Atiq Ur; Mahmood, Hasan
2018-01-01
Recent research in underwater wireless sensor networks (UWSNs) has gained the attention of researchers in academia and industry for a number of applications. They include disaster and earthquake prediction, water quality and environment monitoring, leakage and mine detection, military surveillance and underwater navigation. However, the aquatic medium is associated with a number of limitations and challenges: long multipath delay, high interference and noise, harsh environment, low bandwidth and limited battery life of the sensor nodes. These challenges demand research techniques and strategies to be overcome in an efficient and effective fashion. The design of routing protocols for UWSNs is one of the promising solutions to cope with these challenges. This paper presents a survey of the routing protocols for UWSNs. For the ease of description, the addressed routing protocols are classified into two groups: localization-based and localization-free protocols. These groups are further subdivided according to the problems they address or the major parameters they consider during routing. Unlike the existing surveys, this survey considers only the latest and state-of-the-art routing protocols. In addition, every protocol is described in terms of its routing strategy and the problem it addresses and solves. The merit(s) of each protocol is (are) highlighted along with the cost. A description of the protocols in this fashion has a number of advantages for researchers, as compared to the existing surveys. Firstly, the description of the routing strategy of each protocol makes its routing operation easily understandable. Secondly, the demerit(s) of a protocol provides (provide) insight into overcoming its flaw(s) in future investigation. This, in turn, leads to the foundation of new protocols that are more intelligent, robust and efficient with respect to the desired parameters. Thirdly, a protocol can be selected for the appropriate application based on its described merit(s). Finally, open challenges and research directions are presented for future investigation. PMID:29783686
Methods for conducting bioassays using embryos and larvae of Pacific herring, Clupea pallasi.
Dinnel, Paul A; Middaugh, Douglas P; Schwarck, Nathan T; Farren, Heather M; Haley, Richard K; Hoover, Richard A; Elphick, James; Tobiason, Karen; Marshall, Randall R
2011-02-01
The rapid decrease of several stocks of Pacific herring, Clupea pallasi, in Puget Sound, Washington, has led to concerns about the effects of industrial and nonpoint source contamination on the embryo and larval stages of this and related forage fish species. To address these concerns, the state of Washington and several industries have funded efforts to develop embryo and larval bioassay protocols that can be used by commercial laboratories for routine effluent testing. This article presents the results of research to develop herring embryo and larval bioassay protocols. Factors evaluated during protocol development included temperature, salinity, dissolved oxygen (DO), light intensity, photoperiod, larval feeding regimes, use of brine and artificial sea salts, gonad sources, collection methods, and egg quality.
The use of participant-observation protocol in an industrial engineering research.
Silveira e Silva, Renato da; Sznelwar, Laerte Idal; D'Afonseca e Silva, Victor
2012-01-01
Based on literature, this article aims to present the "participant-observation' research protocol, and its practical application in the industrial engineering field, more specifically within the area of design development, and in the case shown by this article, of interiors' design. The main target is to identify the concept of the method, i.e., from its characteristics to structure a general sense about the subject, so that the protocol can be used in different areas of knowledge, especially those ones which are committed with the scientific research involving the expertise from researchers, and subjective feelings and opinions of the users of an engineering product, and how this knowledge can be benefic for product design, contributing since the earliest stage of design.
Estimation of the percutaneous absorption of styrene in an industrial situation.
Limasset, J C; Simon, P; Poirot, P; Subra, I; Grzebyk, M
1999-01-01
This field study was designed to compare the level of styrene absorbed percutaneously with that absorbed by inhalation in a real situation in the fiberglass-reinforced polyester industry. The study protocol consisted of comparisons of the patterns of urinary excretion of styrene metabolites by four groups of workers, all of whom performed the same task at the same time in the same workshop but wore the following different protective equipment: total protection with an insulating suit and mask, respiratory equipment only, percutaneous protection only, and no protection. The urinary excretion level of the group with total protection did not significantly differ from that of the group with respiratory protection only. Precutaneous absorption is not a particularly important pathway for styrene absorption during stratification work in the polyester industry. Completely insulating personal protective equipment provides no greater level of protection than does a respirator at positive pressure alone.
Identifying thermal breakdown products of thermoplastics.
Guillemot, Marianne; Oury, Benoît; Melin, Sandrine
2017-07-01
Polymers processed to produce plastic articles are subjected to temperatures between 150°C and 450°C or more during overheated processing and breakdowns. Heat-based processing of this nature can lead to emission of volatile organic compounds (VOCs) into the thermoplastic processing shop. In this study, laboratory experiments, qualitative and quantitative emissions measurement in thermoplastic factories were carried out. The first step was to identify the compounds released depending on the thermoplastic nature, the temperature and the type of process. Then a thermal degradation protocol that can extrapolate the laboratory results to industry scenarios was developed. The influence of three parameters on released thermal breakdown products was studied: the sample preparation methods-manual cutting, ambient, or cold grinding-the heating rate during thermal degradation-5, 10 20, and 50°C/min-and the decomposition method-thermogravimetric analysis and pyrolysis. Laboratory results were compared to atmospheric measurements taken at 13 companies to validate the protocol and thereby ensure its representativeness of industrial thermal processing. This protocol was applied to most commonly used thermoplastics to determine their thermal breakdown products and their thermal behaviour. Emissions data collected by personal exposure monitoring and sampling at the process emission area show airborne concentrations of detected compounds to be in the range of 0-3 mg/m 3 under normal operating conditions. Laser cutting or purging operations generate higher pollution levels in particular formaldehyde which was found in some cases at a concentration above the workplace exposure limit.
The difference between “equivalent” and “not different”
Anderson-Cook, Christine M.; Borror, Connie M.
2015-10-27
Often, experimenters wish to establish that populations of units can be considered equivalent to each other, in order to leverage improved knowledge about one population for characterizing the new population, or to establish the comparability of items. Equivalence tests have existed for many years, but their use in industry seems to have been largely restricted to biomedical applications, such as for assessing the equivalence of two drugs or protocols. We present the fundamentals of equivalence tests, compare them to traditional two-sample and ANOVA tests that are better suited to establishing differences in populations, and propose the use of a graphicalmore » summary to compare p-values across different thresholds of practically important differences.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, E.; Engebrecht-Metzger, C.; Horowitz, S.
As BA has grown to include a large and diverse cross-section of the home building and retrofit industries, it has become more important to develop accurate, consistent analysis techniques to measure progress towards the program's goals. The House Simulation Protocol (HSP) document provides guidance to program partners and managers so they can compare energy savings for new construction and retrofit projects. The HSP provides the program with analysis methods that are proven to be effective and reliable in investigating the energy use of advanced energy systems and of entire houses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, E.; Engebrecht, C. Metzger; Horowitz, S.
As Building America has grown to include a large and diverse cross-section of the home building and retrofit industries, it has become more important to develop accurate, consistent analysis techniques to measure progress towards the program's goals. The House Simulation Protocol (HSP) document provides guidance to program partners and managers so they can compare energy savings for new construction and retrofit projects. The HSP provides the program with analysis methods that are proven to be effective and reliable in investigating the energy use of advanced energy systems and of entire houses.
NASA Technical Reports Server (NTRS)
Ivancic, William D.; Glover, Daniel R.; vonDeak, Thomas C.; Bhasin, Kul B.
1998-01-01
The realization of the full potential of the National Information Infrastructure (NH) and Global Information Infrastructure (GII) requires seamless interoperability of emerging satellite networks with terrestrial networks. This requires a cooperative effort between industry, academia and government agencies to develop and advocate new, satellite-friendly communication protocols and modifications to existing communication protocol standards. These groups have recently come together to actively participating in a number of standards making bodies including: the Internet Engineering Task Force (IETF), the Asynchronous Transfer Mode (ATM) Forum, the International Telecommunication Union (ITU) and the Telecommunication Industry Association MA) to ensure that issues regarding efficient use of these protocols over satellite links are not overlooked. This paper will summarize the progress made toward standards development to achieve seamless integration and accelerate the deployment of multimedia applications.
Satellite Communications Using Commercial Protocols
NASA Technical Reports Server (NTRS)
Ivancic, William D.; Griner, James H.; Dimond, Robert; Frantz, Brian D.; Kachmar, Brian; Shell, Dan
2000-01-01
NASA Glenn Research Center has been working with industry, academia, and other government agencies in assessing commercial communications protocols for satellite and space-based applications. In addition, NASA Glenn has been developing and advocating new satellite-friendly modifications to existing communications protocol standards. This paper summarizes recent research into the applicability of various commercial standard protocols for use over satellite and space- based communications networks as well as expectations for future protocol development. It serves as a reference point from which the detailed work can be readily accessed. Areas that will be addressed include asynchronous-transfer-mode quality of service; completed and ongoing work of the Internet Engineering Task Force; data-link-layer protocol development for unidirectional link routing; and protocols for aeronautical applications, including mobile Internet protocol routing for wireless/mobile hosts and the aeronautical telecommunications network protocol.
Phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography
Ludlow, John B.; Walker, Cameron
2013-01-01
Introduction Increasing use of cone-beam computed tomography in orthodontics has been coupled with heightened concern with the long-term risks of x-ray exposure in orthodontic populations. An industry response to this has been to offer low-exposure alternative scanning options in newer cone-beam computed tomography models. Methods Effective doses resulting from various combinations of field size, and field location comparing child and adult anthropomorphic phantoms using the recently introduced i-CAT FLX cone-beam computed tomography unit were measured with Optical Stimulated Dosimetry using previously validated protocols. Scan protocols included High Resolution (360° rotation, 600 image frames, 120 kVp, 5 mA, 7.4 sec), Standard (360°, 300 frames, 120 kVp, 5 mA, 3.7 sec), QuickScan (180°, 160 frames, 120 kVp, 5 mA, 2 sec) and QuickScan+ (180°, 160 frames, 90 kVp, 3 mA, 2 sec). Contrast-to-noise ratio (CNR) was calculated as a quantitative measure of image quality for the various exposure options using the QUART DVT phantom. Results Child phantom doses were on average 36% greater than Adult phantom doses. QuickScan+ protocols resulted in significantly lower doses than Standard protocols for child (p=0.0167) and adult (p=0.0055) phantoms. 13×16 cm cephalometric fields of view ranged from 11–85 μSv in the adult phantom and 18–120 μSv in the child for QuickScan+ and Standard protocols respectively. CNR was reduced by approximately 2/3rds comparing QuickScan+ to Standard exposure parameters. Conclusions QuickScan+ effective doses are comparable to conventional panoramic examinations. Significant dose reductions are accompanied by significant reductions in image quality. However, this trade-off may be acceptable for certain diagnostic tasks such as interim assessment of treatment results. PMID:24286904
Toward Automating Web Protocol Configuration for a Programmable Logic Controller Emulator
2014-06-19
Security Risks for Industrial Control Systems ,” VDE 2004 Congress, Berlin, Germany, October 2004, pp. 1-7. [Cis12] Cisco, NetFlow Configuration Guide...Date 29 May 2014 Date AFIT-ENG-T-14-J-4 Abstract Industrial Control Systems (ICS) remain vulnerable through attack vectors that exist within programmable...5 2.2 Industrial Control Systems
Advanced Combat Helmet Technical Assessment
2013-05-29
Lastly, we assessed the participation of various stakeholders and industry experts such as active ACH manufacturers and test facilities. Findings... industrially accepted American National Standards Institute (ANSI Z1.4-2008, Sampling Visit us on the web at www.dodig.mil Results in Brief Advanced...statistically principled approach and the lot acceptance test protocol adopts a widely established and industrially accepted sampling procedure. We
Lighting Automation Flying an Earthlike Habitat
NASA Technical Reports Server (NTRS)
Clark, Toni A.; Kolomenski, Andrei
2017-01-01
Currently, spacecraft lighting systems are not demonstrating innovations in automation due to perceived costs in designing circuitry for the communication and automation of lights. The majority of spacecraft lighting systems employ lamps or zone specific manual switches and dimmers. This type of 'hardwired' solution does not easily convert to automation. With advances in solid state lighting, the potential to enhance a spacecraft habitat is lost if the communication and automation problem is not tackled. If we are to build long duration environments, which provide earth-like habitats, minimize crew time, and optimize spacecraft power reserves, innovation in lighting automation is a must. This project researched the use of the DMX512 communication protocol originally developed for high channel count lighting systems. DMX512 is an internationally governed, industry-accepted, lighting communication protocol with wide industry support. The lighting industry markets a wealth of hardware and software that utilizes DMX512, and there may be incentive to space certify the system. Our goal in this research is to enable the development of automated spacecraft habitats for long duration missions. To transform how spacecraft lighting environments are automated, our project conducted a variety of tests to determine a potential scope of capability. We investigated utilization and application of an industry accepted lighting control protocol, DMX512 by showcasing how the lighting system could help conserve power, assist with lighting countermeasures, and utilize spatial body tracking. We hope evaluation and the demonstrations we built will inspire other NASA engineers, architects and researchers to consider employing DMX512 "smart lighting" capabilities into their system architecture. By using DMX512 we will prove the 'wheel' does not need to be reinvented in terms of smart lighting and future spacecraft can use a standard lighting protocol to produce an effective, optimized and potentially earthlike habitat.
Lighting Automation - Flying an Earthlike Habitat
NASA Technical Reports Server (NTRS)
Clark, Tori A. (Principal Investigator); Kolomenski, Andrei
2017-01-01
Currently, spacecraft lighting systems are not demonstrating innovations in automation due to perceived costs in designing circuitry for the communication and automation of lights. The majority of spacecraft lighting systems employ lamps or zone specific manual switches and dimmers. This type of 'hardwired' solution does not easily convert to automation. With advances in solid state lighting, the potential to enhance a spacecraft habitat is lost if the communication and automation problem is not tackled. If we are to build long duration environments, which provide earth-like habitats, minimize crew time, and optimize spacecraft power reserves, innovation in lighting automation is a must. This project researched the use of the DMX512 communication protocol originally developed for high channel count lighting systems. DMX512 is an internationally governed, industry-accepted, lighting communication protocol with wide industry support. The lighting industry markets a wealth of hardware and software that utilizes DMX512, and there may be incentive to space certify the system. Our goal in this research is to enable the development of automated spacecraft habitats for long duration missions. To transform how spacecraft lighting environments are automated, our project conducted a variety of tests to determine a potential scope of capability. We investigated utilization and application of an industry accepted lighting control protocol, DMX512 by showcasing how the lighting system could help conserve power, assist with lighting countermeasures, and utilize spatial body tracking. We hope evaluation and the demonstrations we built will inspire other NASA engineers, architects and researchers to consider employing DMX512 "smart lighting" capabilities into their system architecture. By using DMX512 we will prove the 'wheel' does not need to be reinvented in terms of smart lighting and future spacecraft can use a standard lighting protocol to produce an effective, optimized and potentially earthlike habitat.
Muiños-Bühl, Anixa; González-Recio, Oscar; Muñoz, María; Óvilo, Cristina; García-Casco, Juan; Fernández, Ana I
2018-06-01
There is a growing interest in understanding the role of the gut microbiome on productive and meat quality-related traits in livestock species in order to develop new useful tools for improving pig production systems and industry. Faecal samples are analysed as a proxy of gut microbiota and here the selection of suitable protocols for faecal sampling and DNA isolation is a critical first step in order to obtain reliable results, even more to compare results obtained from different studies. The aim of the current study was to establish in a cost-effective way, using automated ribosomal intergenic spacer analysis technique, a protocol for porcine faecal sampling and storage at farm and slaughterhouse and to determine the most efficient microbiota DNA isolation kit among those most widely used. Operational Taxonomic Unit profiles were compared from Iberian pig faecal samples collected from rectum or ground, stored with liquid N 2 , room temperature or RNAlater, and processed with QIAamp DNA Stool (Qiagen), PowerFecal DNA Isolation (Mobio) or SpeedTools Tissue DNA extraction (Biotools) commercial kits. The results, focused on prokaryote sampling, based on DNA yield and quality, OTU number and Sørensen similarity Indexes, indicate that the recommended protocol for porcine faecal microbiome sampling at farm should include: the collection from porcine rectum to avoid contamination; the storage in liquid N 2 or even at room temperature, but not in RNAlater; and the isolation of microbiota DNA using PowerFecal DNA Isolation kit. These conditions provide more reliable DNA samples for further microbiome analysis.
Development of EPA Protocol Information Enquiry Service System Based on Embedded ARM Linux
NASA Astrophysics Data System (ADS)
Peng, Daogang; Zhang, Hao; Weng, Jiannian; Li, Hui; Xia, Fei
Industrial Ethernet is a new technology for industrial network communications developed in recent years. In the field of industrial automation in China, EPA is the first standard accepted and published by ISO, and has been included in the fourth edition IEC61158 Fieldbus of NO.14 type. According to EPA standard, Field devices such as industrial field controller, actuator and other instruments are all able to realize communication based on the Ethernet standard. The Atmel AT91RM9200 embedded development board and open source embedded Linux are used to develop an information inquiry service system of EPA protocol based on embedded ARM Linux in this paper. The system is capable of designing an EPA Server program for EPA data acquisition procedures, the EPA information inquiry service is available for programs in local or remote host through Socket interface. The EPA client can access data and information of other EPA equipments on the EPA network when it establishes connection with the monitoring port of the server.
NASA Astrophysics Data System (ADS)
Nikitin, I. A.; Sherstnev, V. S.; Sherstneva, A. I.; Botygin, I. A.
2017-02-01
The results of the research of existent routing protocols in wireless networks and their main features are discussed in the paper. Basing on the protocol data, the routing protocols in wireless networks, including search routing algorithms and phone directory exchange algorithms, are designed with the ‘WiFi-Direct’ technology. Algorithms without IP-protocol were designed, and that enabled one to increase the efficiency of the algorithms while working only with the MAC-addresses of the devices. The developed algorithms are expected to be used in the mobile software engineering with the Android platform taken as base. Easier algorithms and formats of the well-known route protocols, rejection of the IP-protocols enables to use the developed protocols on more primitive mobile devices. Implementation of the protocols to the engineering industry enables to create data transmission networks among working places and mobile robots without any access points.
ACTS 118x: High Speed TCP Interoperability Testing
NASA Technical Reports Server (NTRS)
Brooks, David E.; Buffinton, Craig; Beering, Dave R.; Welch, Arun; Ivancic, William D.; Zernic, Mike; Hoder, Douglas J.
1999-01-01
With the recent explosion of the Internet and the enormous business opportunities available to communication system providers, great interest has developed in improving the efficiency of data transfer over satellite links using the Transmission Control Protocol (TCP) of the Internet Protocol (IP) suite. The NASA's ACTS experiments program initiated a series of TCP experiments to demonstrate scalability of TCP/IP and determine to what extent the protocol can be optimized over a 622 Mbps satellite link. Through partnerships with the government technology oriented labs, computer, telecommunication, and satellite industries NASA Glenn was able to: (1) promote the development of interoperable, high-performance TCP/IP implementations across multiple computing / operating platforms; (2) work with the satellite industry to answer outstanding questions regarding the use of standard protocols (TCP/IP and ATM) for the delivery of advanced data services, and for use in spacecraft architectures; and (3) conduct a series of TCP/IP interoperability tests over OC12 ATM over a satellite network in a multi-vendor environment using ACTS. The experiments' various network configurations and the results are presented.
Remote control of the industry processes. POWERLINK protocol application
NASA Astrophysics Data System (ADS)
Wóbel, A.; Paruzel, D.; Paszkiewicz, B.
2017-08-01
The present technological development enables the use of solutions characterized by a lower failure rate, and work with greater precision. This allows you to obtain the most efficient production, high speed production and reliability of individual components. The main scope of this article was POWERLINK protocol application for communication with the controller B & R through communication Ethernet for recording process parameters. This enables control of run production cycle using an internal network connected to the PC industry. Knowledge of the most important parameters of the production in real time allows detecting of a failure immediately after occurrence. For this purpose, the position of diagnostic use driver X20CP1301 B&R to record measurement data such as pressure, temperature valve between the parties and the torque required to change the valve setting was made. The use of POWERLINK protocol allows for the transmission of information on the status of every 200 μs.
Representing the work of medical protocols for organizational simulation.
Fridsma, D. B.
1998-01-01
Developing and implementing patient care protocols within a specific organizational setting requires knowledge of the protocol, the organization, and the way in which the organization does its work. Computer-based simulation tools have been used in many industries to provide managers with prospective insight into problems of work process and organization design mismatch. Many of these simulation tools are designed for well-understood routine work processes in which there are few contingent tasks. In this paper, we describe theoretic that make it possible to simulate medical protocols using an information-processing theory framework. These simulations will allow medical administrators to test different protocol and organizational designs before actually using them within a particular clinical setting. PMID:9929231
Photonic-based liquid level transmitter using Mach-Zehnder interferometer for industrial application
NASA Astrophysics Data System (ADS)
Singh, Yadvendra; Raghuwanshi, Sanjeev K.; Kumar, Manish
2018-02-01
In the present scenario the process control industries mainly uses 1-5 Volt or 4-20 mA protocol for transmitting the measured signal to remote location operators. These types of protocol prone to interference and limited data transfer rate. To overcome these types of limitation we proposed photonic based transmitter for liquid level measurement which will enhance data transfer rate and interference reduction to eliminate noise signal in the channel during transmission to make transmission more reliable, accurate and consistent in performance. The required mathematical derivation and the principle of operation of the transmitter are shown in the paper.
Sensor Proxy Mobile IPv6 (SPMIPv6)—A Novel Scheme for Mobility Supported IP-WSNs
Islam, Md. Motaharul; Huh, Eui-Nam
2011-01-01
IP based Wireless Sensor Networks (IP-WSNs) are gaining importance for their broad range of applications in health-care, home automation, environmental monitoring, industrial control, vehicle telematics and agricultural monitoring. In all these applications, mobility in the sensor network with special attention to energy efficiency is a major issue to be addressed. Host-based mobility management protocols are not suitable for IP-WSNs because of their energy inefficiency, so network based mobility management protocols can be an alternative for the mobility supported IP-WSNs. In this paper we propose a network based mobility supported IP-WSN protocol called Sensor Proxy Mobile IPv6 (SPMIPv6). We present its architecture, message formats and also evaluate its performance considering signaling cost, mobility cost and energy consumption. Our analysis shows that with respect to the number of IP-WSN nodes, the proposed scheme reduces the signaling cost by 60% and 56%, as well as the mobility cost by 62% and 57%, compared to MIPv6 and PMIPv6, respectively. The simulation results also show that in terms of the number of hops, SPMIPv6 decreases the signaling cost by 56% and 53% as well as mobility cost by 60% and 67% as compared to MIPv6 and PMIPv6 respectively. It also indicates that proposed scheme reduces the level of energy consumption significantly. PMID:22319386
Sensor proxy mobile IPv6 (SPMIPv6)--a novel scheme for mobility supported IP-WSNs.
Islam, Md Motaharul; Huh, Eui-Nam
2011-01-01
IP based Wireless Sensor Networks (IP-WSNs) are gaining importance for their broad range of applications in health-care, home automation, environmental monitoring, industrial control, vehicle telematics and agricultural monitoring. In all these applications, mobility in the sensor network with special attention to energy efficiency is a major issue to be addressed. Host-based mobility management protocols are not suitable for IP-WSNs because of their energy inefficiency, so network based mobility management protocols can be an alternative for the mobility supported IP-WSNs. In this paper we propose a network based mobility supported IP-WSN protocol called Sensor Proxy Mobile IPv6 (SPMIPv6). We present its architecture, message formats and also evaluate its performance considering signaling cost, mobility cost and energy consumption. Our analysis shows that with respect to the number of IP-WSN nodes, the proposed scheme reduces the signaling cost by 60% and 56%, as well as the mobility cost by 62% and 57%, compared to MIPv6 and PMIPv6, respectively. The simulation results also show that in terms of the number of hops, SPMIPv6 decreases the signaling cost by 56% and 53% as well as mobility cost by 60% and 67% as compared to MIPv6 and PMIPv6 respectively. It also indicates that proposed scheme reduces the level of energy consumption significantly.
In Brief: Kyoto Protocol moves forward
NASA Astrophysics Data System (ADS)
Showstack, Randy
2004-10-01
The Russian cabinet's 30 September endorsement of the Kyoto Protocol to the United Nations Framework Convention on Climate Change (UNFCCC) likely clears the way for the treaty's ratification by that country's parliament and for its entry into force. The protocol enters into force when not less than 55 Parties to the Convention, including industrialized countries (so called ``Annex I Parties'') which accounted in total for at least 55 % of the total carbon dioxide emissions for 1990 from that group, officially have agreed to the treaty.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-29
... Electronic Format to the Center for Veterinary Medicine--(OMB Control Number 0910-0524)--Extension Protocols... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0055... Request; Guidance for Industry on How to Submit a Protocol Without Data in Electronic Format to the Center...
15 CFR 782.5 - Where to obtain APR report forms.
Code of Federal Regulations, 2010 CFR
2010-01-01
... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS GENERAL... forms required by the APR may be downloaded from the Internet at http://www.ap.gov. You also may obtain these forms by contacting: Treaty Compliance Division, Bureau of Industry and Security, U.S. Department...
15 CFR 782.5 - Where to obtain APR report forms.
Code of Federal Regulations, 2013 CFR
2013-01-01
... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS GENERAL... forms required by the APR may be downloaded from the Internet at http://www.ap.gov. You also may obtain these forms by contacting: Treaty Compliance Division, Bureau of Industry and Security, U.S. Department...
15 CFR 782.5 - Where to obtain APR report forms.
Code of Federal Regulations, 2011 CFR
2011-01-01
... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS GENERAL... forms required by the APR may be downloaded from the Internet at http://www.ap.gov. You also may obtain these forms by contacting: Treaty Compliance Division, Bureau of Industry and Security, U.S. Department...
15 CFR 782.5 - Where to obtain APR report forms.
Code of Federal Regulations, 2012 CFR
2012-01-01
... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS GENERAL... forms required by the APR may be downloaded from the Internet at http://www.ap.gov. You also may obtain these forms by contacting: Treaty Compliance Division, Bureau of Industry and Security, U.S. Department...
15 CFR 782.5 - Where to obtain APR report forms.
Code of Federal Regulations, 2014 CFR
2014-01-01
... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS GENERAL... forms required by the APR may be downloaded from the Internet at http://www.ap.gov. You also may obtain these forms by contacting: Treaty Compliance Division, Bureau of Industry and Security, U.S. Department...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-05
... European Protocol for the Quality Control of the Physical and Technical Aspects of Mammography Screening... entitled ``Physical Laboratory Testing, Breast Compression System'' to follow the Mammography Quality...] Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance Document...
Electronic Business Transaction Infrastructure Analysis Using Petri Nets and Simulation
ERIC Educational Resources Information Center
Feller, Andrew Lee
2010-01-01
Rapid growth in eBusiness has made industry and commerce increasingly dependent on the hardware and software infrastructure that enables high-volume transaction processing across the Internet. Large transaction volumes at major industrial-firm data centers rely on robust transaction protocols and adequately provisioned hardware capacity to ensure…
Technical Analysis of SSP-21 Protocol
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bromberger, S.
As part of the California Energy Systems for the Twenty-First Century (CES-21) program, in December 2016 San Diego Gas and Electric (SDG&E) contracted with Lawrence Livermore National Laboratory (LLNL) to perform an independent verification and validation (IV&V) of a white paper describing their Secure SCADA Protocol for the Twenty-First Century (SSP-21) in order to analyze the effectiveness and propriety of cryptographic protocol use within the SSP-21 specification. SSP-21 is designed to use cryptographic protocols to provide (optional) encryption, authentication, and nonrepudiation, among other capabilities. The cryptographic protocols to be used reflect current industry standards; future versions of SSP-21 will usemore » other advanced technologies to provide a subset of security services.« less
Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography.
Ludlow, John B; Walker, Cameron
2013-12-01
The increasing use of cone-beam computed tomography in orthodontics has been coupled with heightened concern about the long-term risks of x-ray exposure in orthodontic populations. An industry response to this has been to offer low-exposure alternative scanning options in newer cone-beam computed tomography models. Effective doses resulting from various combinations of field of view size and field location comparing child and adult anthropomorphic phantoms with the recently introduced i-CAT FLX cone-beam computed tomography unit (Imaging Sciences, Hatfield, Pa) were measured with optical stimulated dosimetry using previously validated protocols. Scan protocols included high resolution (360° rotation, 600 image frames, 120 kV[p], 5 mA, 7.4 seconds), standard (360°, 300 frames, 120 kV[p], 5 mA, 3.7 seconds), QuickScan (180°, 160 frames, 120 kV[p], 5 mA, 2 seconds), and QuickScan+ (180°, 160 frames, 90 kV[p], 3 mA, 2 seconds). Contrast-to-noise ratio was calculated as a quantitative measure of image quality for the various exposure options using the QUART DVT phantom. Child phantom doses were on average 36% greater than adult phantom doses. QuickScan+ protocols resulted in significantly lower doses than standard protocols for the child (P = 0.0167) and adult (P = 0.0055) phantoms. The 13 × 16-cm cephalometric fields of view ranged from 11 to 85 μSv in the adult phantom and 18 to 120 μSv in the child phantom for the QuickScan+ and standard protocols, respectively. The contrast-to-noise ratio was reduced by approximately two thirds when comparing QuickScan+ with standard exposure parameters. QuickScan+ effective doses are comparable with conventional panoramic examinations. Significant dose reductions are accompanied by significant reductions in image quality. However, this trade-off might be acceptable for certain diagnostic tasks such as interim assessment of treatment results. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Cadierno, Juan Pedro García; Renedo, J I Serrano; Lopez, E Gil
2006-11-01
The presence of radioactive materials in scrap metal has been detected relatively often in recent years. As a result of an accidental melting of a 137Cs source in a Spanish steel mill (Acerinox) in 1998, the national authorities, the involved private companies, and the main trade unions drafted a protocol for prevention of and responding to such events ("Spanish Protocol"). The Protocol was signed in 1999. The number of subscribing companies is 90. The Protocol is a voluntary agreement defining the radiological surveillance of scrap metal and its products and the duties and rights of the signatories. From the effective date of the Protocol to December 2004, 461 pieces of ferric scrap were detected including sources of radiation and contaminated metal. Four melting incidents have happened in different companies.
Performance analysis of wireless sensor networks in geophysical sensing applications
NASA Astrophysics Data System (ADS)
Uligere Narasimhamurthy, Adithya
Performance is an important criteria to consider before switching from a wired network to a wireless sensing network. Performance is especially important in geophysical sensing where the quality of the sensing system is measured by the precision of the acquired signal. Can a wireless sensing network maintain the same reliability and quality metrics that a wired system provides? Our work focuses on evaluating the wireless GeoMote sensor motes that were developed by previous computer science graduate students at Mines. Specifically, we conducted a set of experiments, namely WalkAway and Linear Array experiments, to characterize the performance of the wireless motes. The motes were also equipped with the Sticking Heartbeat Aperture Resynchronization Protocol (SHARP), a time synchronization protocol developed by a previous computer science graduate student at Mines. This protocol should automatically synchronize the mote's internal clocks and reduce time synchronization errors. We also collected passive data to evaluate the response of GeoMotes to various frequency components associated with the seismic waves. With the data collected from these experiments, we evaluated the performance of the SHARP protocol and compared the performance of our GeoMote wireless system against the industry standard wired seismograph system (Geometric-Geode). Using arrival time analysis and seismic velocity calculations, we set out to answer the following question. Can our wireless sensing system (GeoMotes) perform similarly to a traditional wired system in a realistic scenario?
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-17
...The National Telecommunications and Information Administration (NTIA), on behalf of the U.S. Department of Commerce (Department), will hold a workshop on September 28, 2010, on the importance of the adoption and deployment of Internet Protocol version six (IPv6) addresses for industry, the U.S. Government, and the Internet economy.
The deployment of a large scale object store at the RAL Tier-1
NASA Astrophysics Data System (ADS)
Dewhurst, A.; Johnson, I.; Adams, J.; Canning, B.; Vasilakakos, G.; Packer, A.
2017-10-01
Since 2014, the RAL Tier-1 has been working on deploying a Ceph backed object store. The aim is to replace Castor for disk-only storage. This new service must be scalable to meet the data demands of the LHC to 2020 and beyond. As well as offering access protocols the LHC experiments currently use, it must also provide industry standard access protocols. In order to keep costs down the service must use erasure coding rather than replication to ensure data reliability. This paper will present details of the storage service setup, which has been named Echo, as well as the experience gained from running it. The RAL Tier-1 has also been developing XrootD and GridFTP plugins for Ceph. Both plugins are built on top of the same libraries that write striped data into Ceph and therefore data written by one protocol will be accessible by the other. In the long term we hope the LHC experiments will migrate to industry standard protocols, therefore these plugins will only provide the features needed by the LHC experiments. This paper will report on the development and testing of these plugins.
COMPARISON OF THE EFFECT OF AMERICAN BISON AND CATTLE ON PASTURE AND DIRECT ACCESS STREAMS
If the Bison are managed in a low impact method then we can count on meat that is free of antibiotics, added hormones, and other industry byproducts. In fact, Federal regulations prohibit the use of artificial growth hormones in bison, and industry protocols prohibit the use ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Romberger, Jeff
The HVAC Controls Evaluation Protocol is designed to address evaluation issues for direct digital controls/energy management systems/building automation systems (DDC/EMS/BAS) that are installed to control heating, ventilation, and air-conditioning (HVAC) equipment in commercial and institutional buildings. (This chapter refers to the DDC/EMS/BAS measure as HVAC controls.) This protocol may also be applicable to industrial facilities such as clean rooms and labs, which have either significant HVAC equipment or spaces requiring special environmental conditions.
Characterizing Marine Soundscapes.
Erbe, Christine; McCauley, Robert; Gavrilov, Alexander
2016-01-01
The study of marine soundscapes is becoming widespread and the amount of data collected is increasing rapidly. Data owners (typically academia, industry, government, and defense) are negotiating data sharing and generating potential for data syntheses, comparative studies, analyses of trends, and large-scale and long-term acoustic ecology research. A problem is the lack of standards and commonly agreed protocols for the recording of marine soundscapes, data analysis, and reporting that make a synthesis and comparison of results difficult. We provide a brief overview of the components in a marine soundscape, the hard- and software tools for recording and analyzing marine soundscapes, and common reporting formats.
Riga, Maria; Korres, George; Balatsouras, Dimitrios; Korres, Stavros
2010-07-01
Although occupational noise-induced hearing loss (NIHL) has become a major problem in industrialized societies, there is a notable lack of effective screening protocols to ensure its early diagnosis. The aim of this study was to detect a potential role of extended high frequency (EHF) audiometry in industrial hearing screening protocols. The population consisted of 151 persons, working for 8 hours daily in a noisy environment (90-110 dBA). The changes of hearing thresholds in industrial workers were analyzed, not only with respect to their age, as has been presented by previous studies, but also with respect to the duration of their previous employment. During the first 10 years of employment, the frequencies 12500, 14000 and 16000Hz were the only ones significantly affected. For the second decade of employment, thresholds were significantly elevated only at 2000 and 4000Hz. After exceeding 20 years of employment, the affected frequencies were 250, 500 and 1000Hz. The effects of age on hearing acuity were significant at all frequencies for the first 2 groups. EHF audiometry seems able to identify the first signs of NIHL, much earlier than conventional audiometry, and therefore may need to be implemented in the screening examinations especially of workers with less than 1 decade of employment. Hearing screening protocols could become more efficient by adjusting their frequency ranges according to the frequencies "at risk", which correspond to the duration of the workers' previous employment.
On shaky ground - A study of security vulnerabilities in control protocols
DOE Office of Scientific and Technical Information (OSTI.GOV)
Byres, E. J.; Huffman, D.; Kube, N.
2006-07-01
The recent introduction of information technologies such as Ethernet R into nuclear industry control devices has resulted in significantly less isolation from the outside world. This raises the question of whether these systems could be attacked by malware, network hackers or professional criminals to cause disruption to critical operations in a manner similar to the impacts now felt in the business world. To help answer this question, a study was undertaken to test a representative control protocol to determine if it had vulnerabilities that could be exploited. A framework was created in which a test could express a large numbermore » of test cases in very compact formal language. This in turn, allowed for the economical automation of both the generation of selectively malformed protocol traffic and the measurement of device under test's (DUT) behavior in response to this traffic. Approximately 5000 protocol conformance tests were run against two major brands of industrial controller. More than 60 categories of errors were discovered, the majority of which were in the form of incorrect error responses to malformed traffic. Several malformed packets however, caused the device to respond or communicate in inappropriate ways. These would be relatively simple for an attacker to inject into a system and could result in the plant operator losing complete view or control of the control device. Based on this relatively small set of devices, we believe that the nuclear industry urgently needs to adopt better security robustness testing of control devices as standard practice. (authors)« less
NASA Astrophysics Data System (ADS)
Frieler, Katja; Lange, Stefan; Piontek, Franziska; Reyer, Christopher P. O.; Schewe, Jacob; Warszawski, Lila; Zhao, Fang; Chini, Louise; Denvil, Sebastien; Emanuel, Kerry; Geiger, Tobias; Halladay, Kate; Hurtt, George; Mengel, Matthias; Murakami, Daisuke; Ostberg, Sebastian; Popp, Alexander; Riva, Riccardo; Stevanovic, Miodrag; Suzuki, Tatsuo; Volkholz, Jan; Burke, Eleanor; Ciais, Philippe; Ebi, Kristie; Eddy, Tyler D.; Elliott, Joshua; Galbraith, Eric; Gosling, Simon N.; Hattermann, Fred; Hickler, Thomas; Hinkel, Jochen; Hof, Christian; Huber, Veronika; Jägermeyr, Jonas; Krysanova, Valentina; Marcé, Rafael; Müller Schmied, Hannes; Mouratiadou, Ioanna; Pierson, Don; Tittensor, Derek P.; Vautard, Robert; van Vliet, Michelle; Biber, Matthias F.; Betts, Richard A.; Bodirsky, Benjamin Leon; Deryng, Delphine; Frolking, Steve; Jones, Chris D.; Lotze, Heike K.; Lotze-Campen, Hermann; Sahajpal, Ritvik; Thonicke, Kirsten; Tian, Hanqin; Yamagata, Yoshiki
2017-11-01
In Paris, France, December 2015, the Conference of the Parties (COP) to the United Nations Framework Convention on Climate Change (UNFCCC) invited the Intergovernmental Panel on Climate Change (IPCC) to provide a special report in 2018 on the impacts of global warming of 1.5 °C above pre-industrial levels and related global greenhouse gas emission pathways
. In Nairobi, Kenya, April 2016, the IPCC panel accepted the invitation. Here we describe the response devised within the Inter-Sectoral Impact Model Intercomparison Project (ISIMIP) to provide tailored, cross-sectorally consistent impact projections to broaden the scientific basis for the report. The simulation protocol is designed to allow for (1) separation of the impacts of historical warming starting from pre-industrial conditions from impacts of other drivers such as historical land-use changes (based on pre-industrial and historical impact model simulations); (2) quantification of the impacts of additional warming up to 1.5 °C, including a potential overshoot and long-term impacts up to 2299, and comparison to higher levels of global mean temperature change (based on the low-emissions Representative Concentration Pathway RCP2.6 and a no-mitigation pathway RCP6.0) with socio-economic conditions fixed at 2005 levels; and (3) assessment of the climate effects based on the same climate scenarios while accounting for simultaneous changes in socio-economic conditions following the middle-of-the-road Shared Socioeconomic Pathway (SSP2, Fricko et al., 2016) and in particular differential bioenergy requirements associated with the transformation of the energy system to comply with RCP2.6 compared to RCP6.0. With the aim of providing the scientific basis for an aggregation of impacts across sectors and analysis of cross-sectoral interactions that may dampen or amplify sectoral impacts, the protocol is designed to facilitate consistent impact projections from a range of impact models across different sectors (global and regional hydrology, lakes, global crops, global vegetation, regional forests, global and regional marine ecosystems and fisheries, global and regional coastal infrastructure, energy supply and demand, temperature-related mortality, and global terrestrial biodiversity).
iSAFT Protocol Validation Platform for On-Board Data Networks
NASA Astrophysics Data System (ADS)
Tavoularis, Antonis; Kollias, Vangelis; Marinis, Kostas
2014-08-01
iSAFT is an integrated powerful HW/SW environmentfor the simulation, validation & monitoring of satellite/spacecraft on-board data networks supporting simultaneously a wide range of protocols (RMAP, PTP, CCSDS Space Packet, TM/TC, CANopen, etc.) and network interfaces (SpaceWire, ECSS MIL-STD-1553, ECSS CAN). It is based on over 20 years of TELETEL's experience in the area of protocol validation in the telecommunications and aeronautical sectors, and it has been fully re-engineered in cooperation of TELETEL with ESA & space Primes, to comply with space on-board industrial validation requirements (ECSS, EGSE, AIT, AIV, etc.). iSAFT is highly modular and expandable to support new network interfaces & protocols and it is based on the powerful iSAFT graphical tool chain (Protocol Analyser / Recorder, TestRunner, Device Simulator, Traffic Generator, etc.).
Coconut coir pith lignin: A physicochemical and thermal characterization.
Asoka Panamgama, L; Peramune, P R U S K
2018-07-01
The structural and thermal features of coconut coir pith lignin, isolated by three different extraction protocols incorporating two different energy supply sources, were characterized by different analytical tools. The three different chemical extraction protocols were alkaline - 7.5% (w/v) NaOH, organosolv - 85% (v/v) formic and acetic acids at 7:3 (v/v) ratio and polyethylene glycol (PEG): water ratio at 80:20wt%. The two sources of energy were thermal or microwave. Raw lignins were modified by epichlorohydrin to enhance reactivity, and the characteristics of raw and modified lignins were comparatively analysed. Using the thermal energy source, the alkaline and organosolv processes obtained the highest and lowest lignin yields of 26.4±1.5wt% and 3.4±0.2wt%, respectively, as shown by wet chemical analysis. Specific functional group analysis by Fourier transform infrared spectra (FTIR) revealed that significantly different amounts of hydroxyl and carbonyl groups exist in alkaline, organosolv and PEG lignins. Thermogravimetric analysis (TGA) illustrated that the lowest degradation onset temperature was recorded for organosolv lignin, and the overall order was organosolv
Ramírez Fernández, María Piedad; Mazón, Patricia; Gehrke, Sergio A.; Calvo-Guirado, Jose Luis; De Aza, Piedad N.
2017-01-01
Detailed information about graft material characteristic is crucial to evaluate their clinical outcomes. The present study evaluates the physico-chemical characteristics of two xenografts manufactured on an industrial scale deproteinized at different temperatures (non-sintered and sintered) in accordance with a protocol previously used in sinus lift procedures. It compares how the physico-chemical properties influence the material’s performance in vivo by a histomorphometric study in retrieved bone biopsies following maxillary sinus augmentation in 10 clinical cases. An X-ray diffraction analysis revealed the typical structure of hydroxyapatite (HA) for both materials. Both xenografts were porous and exhibited intraparticle pores. Strong differences were observed in terms of porosity, crystallinity, and calcium/phosphate. Histomorphometric measurements on the bone biopsies showed statistically significant differences. The physic-chemical assessment of both xenografts, made in accordance with the protocol developed on an industrial scale, confirmed that these products present excellent biocompatibilitity, with similar characteristics to natural bone. The sintered HA xenografts exhibited greater osteoconductivity, but were not completely resorbable (30.80 ± 0.88% residual material). The non-sintered HA xenografts induced about 25.92 ± 1.61% of new bone and a high level of degradation after six months of implantation. Differences in the physico-chemical characteristics found between the two HA xenografts determined a different behavior for this material. PMID:28772984
Emulation of Industrial Control Field Device Protocols
2013-03-01
platforms such as the Arduino ( based on the Atmel AVR architecture) or popular PIC architecture based devices, which are programmed for specific functions...UNIVERSITY AIR FORCE INSTITUTE OF TECHNOLOGY Wright-Patterson Air Force Base , Ohio DISTRIBUTION STATEMENT A. APPROVED FOR PUBLIC RELEASE; DISTRIBUTION...confidence intervals for the mean. Based on these results, extensive knowledge of the specific implementations of the protocols or timing profiles of the
Test Protocols for Advanced Inverter Interoperability Functions – Main Document
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Jay Dean; Gonzalez, Sigifredo; Ralph, Mark E.
2013-11-01
Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated onmore » grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not currently required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already apparent as some of these inverter capabilities are being incorporated in large demonstration and commercial projects. The test protocols are intended to be used to verify acceptable performance of inverters within the standard framework described in IEC TR 61850-90-7. These test protocols, as they are refined and validated over time, can become precursors for future certification test procedures for DER advanced grid support functions.« less
Test Protocols for Advanced Inverter Interoperability Functions - Appendices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Jay Dean; Gonzalez, Sigifredo; Ralph, Mark E.
2013-11-01
Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated onmore » grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not now required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already apparent as some of these inverter capabilities are being incorporated in large demonstration and commercial projects. The test protocols are intended to be used to verify acceptable performance of inverters within the standard framework described in IEC TR 61850-90-7. These test protocols, as they are refined and validated over time, can become precursors for future certification test procedures for DER advanced grid support functions.« less
Probst, Pascal; Grummich, Kathrin; Ulrich, Alexis; Büchler, Markus W; Knebel, Phillip; Diener, Markus K
2014-11-27
Industry sponsorship has been identified as a factor correlating with positive research findings in several fields of medical science. To date, the influence of industry sponsorship in general and abdominal surgery has not been fully studied. This protocol describes the rationale and planned conduct of a systematic review to determine the association between industry sponsorship and positive outcome in randomised controlled trials in general and abdominal surgery. A literature search in the Cochrane Library, MEDLINE and EMBASE and additional hand searches in relevant citations will be conducted. In order to cover all relevant areas of general and abdominal surgery, a new literature search strategy called multi-PICO search strategy (MPSS) has been developed. No language restriction will be applied. The search will be limited to publications between January 1985 and July 2014. Information on funding source, outcome, study characteristics and methodological quality will be extracted.The association between industry sponsorship and positive outcome will be tested by a chi-squared test. A multivariate logistic regression analysis will be performed to control for possible confounders, such as number of study centres, multinational trials, methodological quality, journal impact factor and sample size. This study was designed to clarify whether industry-sponsored trials report more positive outcomes than non-industry trials. It will be the first study to evaluate this topic in general and abdominal surgery. The findings of this study will enable surgical societies, in particular, to give advice about cooperation with the industry and disclosure of funding source based on empirical evidence. PROSPERO CRD42014010802.
NASA Astrophysics Data System (ADS)
DeGrasse, Stacey; Conrad, Stephen; DiStefano, Paul; Vanegas, Camilo; Wallace, David; Jensen, Pete; Hickey, J. Michael; Cenci, Florence; Pitt, Jaclyn; Deardorff, Dave; Rubio, Fernando; Easy, Dorothy; Donovan, Mary Anne; Laycock, Maurice; Rouse, Debbie; Mullen, John
2014-05-01
Paralytic shellfish poisoning (PSP) is the foodborne intoxication associated with the consumption of seafood contaminated with naturally occurring neurotoxins known as paralytic shellfish toxins. To protect public health from this potentially fatal syndrome, harvesting closures are implemented when toxins exceed the regulatory action level. Traditional monitoring programs established by state shellfish authorities allow for timely closures in state waters with minimal negative impacts on industry. However, such monitoring programs are not feasible in federal offshore waters given their distance from shore and the range of their spatial coverage. Thus innovative management strategies were investigated for these offshore resources. Georges Bank, an offshore resource with an estimated market value of more than 3 billion in Atlantic surfclams and ocean quahogs, has been closed to harvesting following a temporary ban in 1989 and a subsequent indefinite closure in 1990 due to the risk of PSP. As a means of managing this risk and allowing harvest of safe shellfish from this important resource, the Onboard Screening Dockside Testing Protocol (referred to as the Protocol) was developed by the US Food and Drug Administration (FDA), National Marine Fisheries Service (NMFS), state shellfish control authorities, and industry. The Protocol, which sets forth control measures to ensure product safety and public health protection, was endorsed by the Interstate Shellfish Sanitation Conference (ISSC) for pilot testing. Briefly, the pilot study Protocol required that (1) the fishing vessel receive a permit from NMFS to harvest in closed waters, (2) a miniμm of five shellfish samples per intended harvest lot be tested for PSP toxins onboard, and (3) harvesting only occur when the samples tested from the intended fishing area are negative using the Jellett Rapid Tests or Abraxis Shipboard ELISA kits. Finally, product landed under the Protocol was confirmed to be safe for consumption using the mouse bioassay (MBA) prior to its introduction into commerce. This paper presents data from the pilot study, with primary focus on the advantages and challenges of the field kits employed onboard compared to the dockside MBA, which has served as the longstanding regulatory method for PSP toxins. In 2010 alone, the successful pilot study resulted in the safe harvest of over 2.7 million worth of surfclams in an area that has otherwise been unavailable for decades. Due to the success of this pilot study, the Protocol was adopted into the National Shellfish Sanitation Program Model Ordinance as an approved marine biotoxin control strategy for use in federal waters at the 2011 ISSC Biennial Meeting. In January 2013 a portion of Georges Bank was reopened for the harvest of Atlantic surfclams and ocean quahogs to fishermen following the Protocol.
SNE Industrial Fieldbus Interface
NASA Technical Reports Server (NTRS)
Lucena, Angel; Raines, Matthew; Oostdyk, Rebecca; Mata, Carlos
2011-01-01
Programmable logic controllers (PLCs) have very limited diagnostic and no prognostic capabilities, while current smart sensor designs do not have the capability to communicate over Fieldbus networks. The aim is to interface smart sensors with PLCs so that health and status information, such as failure mode identification and measurement tolerance, can be communicated via an industrial Fieldbus such as ControlNet. The SNE Industrial Fieldbus Interface (SIFI) is an embedded device that acts as a communication module in a networked smart sensor. The purpose is to enable a smart sensor to communicate health and status information to other devices, such as PLCs, via an industrial Fieldbus networking protocol. The SNE (Smart Network Element) is attached to a commercial off-the-shelf Any bus-S interface module through the SIFI. Numerous Anybus-S modules are available, each one designed to interface with a specific Fieldbus. Development of the SIFI focused on communications using the ControlNet protocol, but any of the Anybus-S modules can be used. The SIFI communicates with the Any-bus module via a data buffer and mailbox system on the Anybus module, and supplies power to the module. The Anybus module transmits and receives data on the Fieldbus using the proper protocol. The SIFI is intended to be connected to other existing SNE modules in order to monitor the health and status of a transducer. The SIFI can also monitor aspects of its own health using an onboard watchdog timer and voltage monitors. The SIFI also has the hardware to drive a touchscreen LCD (liquid crystal display) unit for manual configuration and status monitoring.
Beard, Brian B; Kainz, Wolfgang; Onishi, Teruo; Iyama, Takahiro; Watanabe, Soichi; Fujiwara, Osamu; Wang, Jianqing; Bit-Babik, Giorgi; Faraone, Antonio; Wiart, Joe; Christ, Andreas; Kuster, Niels; Lee, Ae-Kyoung; Kroeze, Hugo; Siegbahn, Martin; Keshvari, Jafar; Abrishamkar, Houman; Simon, Winfried; Manteuffel, Dirk; Nikoloski, Neviana
2006-06-05
The specific absorption rates (SAR) determined computationally in the specific anthropomorphic mannequin (SAM) and anatomically correct models of the human head when exposed to a mobile phone model are compared as part of a study organized by IEEE Standards Coordinating Committee 34, SubCommittee 2, and Working Group 2, and carried out by an international task force comprising 14 government, academic, and industrial research institutions. The detailed study protocol defined the computational head and mobile phone models. The participants used different finite-difference time-domain software and independently positioned the mobile phone and head models in accordance with the protocol. The results show that when the pinna SAR is calculated separately from the head SAR, SAM produced a higher SAR in the head than the anatomically correct head models. Also the larger (adult) head produced a statistically significant higher peak SAR for both the 1- and 10-g averages than did the smaller (child) head for all conditions of frequency and position.
A Taxonomy of Attacks on the DNP3 Protocol
NASA Astrophysics Data System (ADS)
East, Samuel; Butts, Jonathan; Papa, Mauricio; Shenoi, Sujeet
Distributed Network Protocol (DNP3) is the predominant SCADA protocol in the energy sector - more than 75% of North American electric utilities currently use DNP3 for industrial control applications. This paper presents a taxonomy of attacks on the protocol. The attacks are classified based on targets (control center, outstation devices and network/communication paths) and threat categories (interception, interruption, modification and fabrication). To facilitate risk analysis and mitigation strategies, the attacks are associated with the specific DNP3 protocol layers they exploit. Also, the operational impact of the attacks is categorized in terms of three key SCADA objectives: process confi- dentiality, process awareness and process control. The attack taxonomy clarifies the nature and scope of the threats to DNP3 systems, and can provide insights into the relative costs and benefits of implementing mitigation strategies.
NASA and Industry Benefits of ACTS High Speed Network Interoperability Experiments
NASA Technical Reports Server (NTRS)
Zernic, M. J.; Beering, D. R.; Brooks, D. E.
2000-01-01
This paper provides synopses of the design. implementation, and results of key high data rate communications experiments utilizing the technologies of NASA's Advanced Communications Technology Satellite (ACTS). Specifically, the network protocol and interoperability performance aspects will be highlighted. The objectives of these key experiments will be discussed in their relevant context to NASA missions, as well as, to the comprehensive communications industry. Discussion of the experiment implementation will highlight the technical aspects of hybrid network connectivity, a variety of high-speed interoperability architectures, a variety of network node platforms, protocol layers, internet-based applications, and new work focused on distinguishing between link errors and congestion. In addition, this paper describes the impact of leveraging government-industry partnerships to achieve technical progress and forge synergistic relationships. These relationships will be the key to success as NASA seeks to combine commercially available technology with its own internal technology developments to realize more robust and cost effective communications for space operations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romberger, Jeff
An adjustable-speed drive (ASD) includes all devices that vary the speed of a rotating load, including those that vary the motor speed and linkage devices that allow constant motor speed while varying the load speed. The Variable Frequency Drive Evaluation Protocol presented here addresses evaluation issues for variable-frequency drives (VFDs) installed on commercial and industrial motor-driven centrifugal fans and pumps for which torque varies with speed. Constant torque load applications, such as those for positive displacement pumps, are not covered by this protocol.
Backup key generation model for one-time password security protocol
NASA Astrophysics Data System (ADS)
Jeyanthi, N.; Kundu, Sourav
2017-11-01
The use of one-time password (OTP) has ushered new life into the existing authentication protocols used by the software industry. It introduced a second layer of security to the traditional username-password authentication, thus coining the term, two-factor authentication. One of the drawbacks of this protocol is the unreliability of the hardware token at the time of authentication. This paper proposes a simple backup key model that can be associated with the real world applications’user database, which would allow a user to circumvent the second authentication stage, in the event of unavailability of the hardware token.
Energy and Process Assessment Protocol for Industrial Buildings
2007-05-01
address production and maintenance needs at U.S. Army Arsenals and Depots. The Protocol is partly the result of an international collaboration under...the International Energy Agency “Energy Conservation in Buildings and Community Systems” Annex 46, Subtask A. A group of government, institutional...Optimization Technology.” This is also a part of the IEA-ECBCS ( International Energy Agency – En- ergy Conservation in Buildings and Community Systems
Security Implications of OPC, OLE, DCOM, and RPC in Control Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2006-01-01
OPC is a collection of software programming standards and interfaces used in the process control industry. It is intended to provide open connectivity and vendor equipment interoperability. The use of OPC technology simplifies the development of control systems that integrate components from multiple vendors and support multiple control protocols. OPC-compliant products are available from most control system vendors, and are widely used in the process control industry. OPC was originally known as OLE for Process Control; the first standards for OPC were based on underlying services in the Microsoft Windows computing environment. These underlying services (OLE [Object Linking and Embedding],more » DCOM [Distributed Component Object Model], and RPC [Remote Procedure Call]) have been the source of many severe security vulnerabilities. It is not feasible to automatically apply vendor patches and service packs to mitigate these vulnerabilities in a control systems environment. Control systems using the original OPC data access technology can thus inherit the vulnerabilities associated with these services. Current OPC standardization efforts are moving away from the original focus on Microsoft protocols, with a distinct trend toward web-based protocols that are independent of any particular operating system. However, the installed base of OPC equipment consists mainly of legacy implementations of the OLE for Process Control protocols.« less
Scada Malware, a Proof of Concept
NASA Astrophysics Data System (ADS)
Carcano, Andrea; Fovino, Igor Nai; Masera, Marcelo; Trombetta, Alberto
Critical Infrastructures are nowadays exposed to new kind of threats. The cause of such threats is related to the large number of new vulnerabilities and architectural weaknesses introduced by the extensive use of ICT and Network technologies into such complex critical systems. Of particular interest are the set of vulnerabilities related to the class of communication protocols normally known as “SCADA” protocols, under which fall all the communication protocols used to remotely control the RTU devices of an industrial system. In this paper we present a proof of concept of the potential effects of a set of computer malware specifically designed and created in order to impact, by taking advantage of some vulnerabilities of the ModBUS protocol, on a typical Supervisory Control and Data Acquisition system.
Franco, Diogo; Franco, Talita; Schettino, Angélica Maria; Filho, João Medeiros Tavares; Vendramin, Fabiel Spani
2012-10-01
Plasma has been widely studied and used in many different situations to speed up healing with better tissue adherence and hemostasis. Research projects are now attempting to isolate platelet-rich plasma (PRP) and platelet-poor plasma (PPP), making better use of their properties, particularly during operations and for wounds that are slow to heal. In view of the wide diversity of industrial machines and extraction protocols, together with the variety of industrially produced biologic glues, this article suggests an option for obtaining PRP, PPP, and human thrombin for autologous use. A way of obtaining PRP, PPP, and thrombin is reproduced through a protocol defined and established by the authors. Autologous thrombin and plasma were obtained through the collection and successive centrifugation of ten whole blood samples, until the desired hemocomponents were isolated, followed by quantitative and qualitative analyses of the elements obtained. The mean platelet concentration obtained was 6.03 × 10(8) platelets/ml, with a mean thrombin concentration of 33.54 nM, both values compatible with reports in the literature when different protocols are applied. The protocol described is a good option for the preparation and application of PRP, PPP, and autologous thrombin, particularly as they can be obtained simultaneously, eliminating the possibilities of viral contamination and allergic reactions. Moreover, the cost of this procedure is low, it is easy to perform, and replicable. This journal requires that authors assign a level of evidence to each article.
Low-voltage chest CT: another way to reduce the radiation dose in asbestos-exposed patients.
Macía-Suárez, D; Sánchez-Rodríguez, E; Lopez-Calviño, B; Diego, C; Pombar, M
2017-09-01
To assess whether low voltage chest computed tomography (CT) can be used to successfully diagnose disease in patients with asbestos exposure. Fifty-six former employees of the shipbuilding industry, who were candidates to receive a standard-dose chest CT due to their occupational exposure to asbestos, underwent a routine CT. Immediately after this initial CT, they underwent a second acquisition using low-dose chest CT parameters, based on a low potential (80 kV) and limited tube current. The findings of the two CT protocols were compared based on typical diseases associated with asbestos exposure. The kappa coefficient for each parameter and for an overall rating (grouping them based on mediastinal, pleural, and pulmonary findings) were calculated in order to test for correlations between the two protocols. A good correlation between routine and low-dose CT was demonstrated for most parameters with a mean radiation dose reduction of up to 83% of the effective dose based on the dose-length product between protocols. Low-dose chest CT, based on a limited tube potential, is useful for patients with an asbestos exposure background. Low-dose chest CT can be successfully used to minimise the radiation dose received by patients, as this protocol produced an estimated mean effective dose similar to that of an abdominal or pelvis plain film. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Fully Automated Sample Preparation for Ultrafast N-Glycosylation Analysis of Antibody Therapeutics.
Szigeti, Marton; Lew, Clarence; Roby, Keith; Guttman, Andras
2016-04-01
There is a growing demand in the biopharmaceutical industry for high-throughput, large-scale N-glycosylation profiling of therapeutic antibodies in all phases of product development, but especially during clone selection when hundreds of samples should be analyzed in a short period of time to assure their glycosylation-based biological activity. Our group has recently developed a magnetic bead-based protocol for N-glycosylation analysis of glycoproteins to alleviate the hard-to-automate centrifugation and vacuum-centrifugation steps of the currently used protocols. Glycan release, fluorophore labeling, and cleanup were all optimized, resulting in a <4 h magnetic bead-based process with excellent yield and good repeatability. This article demonstrates the next level of this work by automating all steps of the optimized magnetic bead-based protocol from endoglycosidase digestion, through fluorophore labeling and cleanup with high-throughput sample processing in 96-well plate format, using an automated laboratory workstation. Capillary electrophoresis analysis of the fluorophore-labeled glycans was also optimized for rapid (<3 min) separation to accommodate the high-throughput processing of the automated sample preparation workflow. Ultrafast N-glycosylation analyses of several commercially relevant antibody therapeutics are also shown and compared to their biosimilar counterparts, addressing the biological significance of the differences. © 2015 Society for Laboratory Automation and Screening.
Iyama, Yuji; Nakaura, Takeshi; Yokoyama, Koichi; Kidoh, Masafumi; Harada, Kazunori; Oda, Seitaro; Tokuyasu, Shinichi; Yamashita, Yasuyuki
This study aimed to evaluate the feasibility of a low contrast, low-radiation dose protocol of 80-peak kilovoltage (kVp) with prospective electrocardiography-gated cardiac computed tomography (CT) using knowledge-based iterative model reconstruction (IMR). Thirty patients underwent an 80-kVp prospective electrocardiography-gated cardiac CT with low-contrast agent (222-mg iodine per kilogram of body weight) dose. We also enrolled 30 consecutive patients who were scanned with a 120-kVp cardiac CT with filtered back projection using the standard contrast agent dose (370-mg iodine per kilogram of body weight) as a historical control group. We evaluated the radiation dose for the 2 groups. The 80-kVp images were reconstructed with filtered back projection (protocol A), hybrid iterative reconstruction (HIR, protocol B), and IMR (protocol C). We compared CT numbers, image noise, and contrast-to-noise ratio among 120-kVp protocol, protocol A, protocol B, and protocol C. In addition, we compared the noise reduction rate between HIR and IMR. Two independent readers compared image contrast, image noise, image sharpness, unfamiliar image texture, and overall image quality among the 4 protocols. The estimated effective dose (ED) of the 80-kVp protocol was 74% lower than that of the 120-kVp protocol (1.4 vs 5.4 mSv). The contrast-to-noise ratio of protocol C was significantly higher than that of protocol A. The noise reduction rate of IMR was significantly higher than that of HIR (P < 0.01). There was no significant difference in almost all qualitative image quality between 120-kVp protocol and protocol C except for image contrast. A 80-kVp protocol with IMR yields higher image quality with 74% decreased radiation dose and 40% decreased contrast agent dose as compared with a 120-kVp protocol, while decreasing more image noise compared with the 80-kVp protocol with HIR.
A design protocol for tailoring ice-templated scaffold structure
Pawelec, K. M.; Husmann, A.; Best, S. M.; Cameron, R. E.
2014-01-01
In this paper, we show, for the first time, the key link between scaffold architecture and latent heat evolution during the production of porous biomedical collagen structures using freeze-drying. Collagen scaffolds are used widely in the biomedical industry for the repair and reconstruction of skeletal tissues and organs. Freeze-drying of collagen slurries is a standard industrial process, and, until now, the literature has sought to characterize the influence of set processing parameters including the freezing protocol and weight percentage of collagen. However, we are able to demonstrate, by monitoring the local thermal events within the slurry during solidification, that nucleation, growth and annealing processes can be controlled, and therefore we are able to control the resulting scaffold architecture. Based on our correlation of thermal profile measurements with scaffold architecture, we hypothesize that there is a link between the fundamental freezing of ice and the structure of scaffolds, which suggests that this concept is applicable not only for collagen but also for ceramics and pharmaceuticals. We present a design protocol of strategies for tailoring the ice-templated scaffold structure. PMID:24402916
Lightweight CoAP-Based Bootstrapping Service for the Internet of Things.
Garcia-Carrillo, Dan; Marin-Lopez, Rafael
2016-03-11
The Internet of Things (IoT) is becoming increasingly important in several fields of industrial applications and personal applications, such as medical e-health, smart cities, etc. The research into protocols and security aspects related to this area is continuously advancing in making these networks more reliable and secure, taking into account these aspects by design. Bootstrapping is a procedure by which a user obtains key material and configuration information, among other parameters, to operate as an authenticated party in a security domain. Until now solutions have focused on re-using security protocols that were not developed for IoT constraints. For this reason, in this work we propose a design and implementation of a lightweight bootstrapping service for IoT networks that leverages one of the application protocols used in IoT : Constrained Application Protocol (CoAP). Additionally, in order to provide flexibility, scalability, support for large scale deployment, accountability and identity federation, our design uses technologies such as the Extensible Authentication Protocol (EAP) and Authentication Authorization and Accounting (AAA). We have named this service CoAP-EAP. First, we review the state of the art in the field of bootstrapping and specifically for IoT. Second, we detail the bootstrapping service: the architecture with entities and interfaces and the flow operation. Third, we obtain performance measurements of CoAP-EAP (bootstrapping time, memory footprint, message processing time, message length and energy consumption) and compare them with PANATIKI. The most significant and constrained representative of the bootstrapping solutions related with CoAP-EAP. As we will show, our solution provides significant improvements, mainly due to an important reduction of the message length.
Lightweight CoAP-Based Bootstrapping Service for the Internet of Things
Garcia-Carrillo, Dan; Marin-Lopez, Rafael
2016-01-01
The Internet of Things (IoT) is becoming increasingly important in several fields of industrial applications and personal applications, such as medical e-health, smart cities, etc. The research into protocols and security aspects related to this area is continuously advancing in making these networks more reliable and secure, taking into account these aspects by design. Bootstrapping is a procedure by which a user obtains key material and configuration information, among other parameters, to operate as an authenticated party in a security domain. Until now solutions have focused on re-using security protocols that were not developed for IoT constraints. For this reason, in this work we propose a design and implementation of a lightweight bootstrapping service for IoT networks that leverages one of the application protocols used in IoT : Constrained Application Protocol (CoAP). Additionally, in order to provide flexibility, scalability, support for large scale deployment, accountability and identity federation, our design uses technologies such as the Extensible Authentication Protocol (EAP) and Authentication Authorization and Accounting (AAA). We have named this service CoAP-EAP. First, we review the state of the art in the field of bootstrapping and specifically for IoT. Second, we detail the bootstrapping service: the architecture with entities and interfaces and the flow operation. Third, we obtain performance measurements of CoAP-EAP (bootstrapping time, memory footprint, message processing time, message length and energy consumption) and compare them with PANATIKI. The most significant and constrained representative of the bootstrapping solutions related with CoAP-EAP. As we will show, our solution provides significant improvements, mainly due to an important reduction of the message length. PMID:26978362
Rani, Anupama; Sharma, Vivek; Arora, Sumit; Lal, Darshan; Kumar, Anil
2015-04-01
Detection of milk fat adulteration with foreign fats/oils continues to be a challenge for the dairy industry as well as food testing laboratories, especially in the present scenario of rampant adulteration using the scientific knowledge by unscrupulous persons involved in the trade. In the present investigation a rapid reversed-phase thin layer chromatographic (RP-TLC) protocol was standardized to ascertain the purity of milk fat. RP-TLC protocol did not show any false positive results in the genuine ghee (clarified butter fat) samples of known origin. Adulteration of ghee with coconut oil up to 7. 5 %, soybean oil, sunflower oil and groundnut oil up to 1 %, while, designer oil up to 2 % level could be detected using the standardized RP-TLC protocol. The protocol standardized is rapid and convenient to use.
Compact Modbus TCP/IP protocol for data acquisition systems based on limited hardware resources
NASA Astrophysics Data System (ADS)
Bai, Q.; Jin, B.; Wang, D.; Wang, Y.; Liu, X.
2018-04-01
The Modbus TCP/IP has been a standard industry communication protocol and widely utilized for establishing sensor-cloud platforms on the Internet. However, numerous existing data acquisition systems built on traditional single-chip microcontrollers without sufficient resources cannot support it, because the complete Modbus TCP/IP protocol always works dependent on a full operating system which occupies abundant hardware resources. Hence, a compact Modbus TCP/IP protocol is proposed in this work to make it run efficiently and stably even on a resource-limited hardware platform. Firstly, the Modbus TCP/IP protocol stack is analyzed and the refined protocol suite is rebuilt by streamlining the typical TCP/IP suite. Then, specific implementation of every hierarchical layer is respectively presented in detail according to the protocol structure. Besides, the compact protocol is implemented in a traditional microprocessor to validate the feasibility of the scheme. Finally, the performance of the proposed scenario is assessed. The experimental results demonstrate that message packets match the frame format of Modbus TCP/IP protocol and the average bandwidth reaches to 1.15 Mbps. The compact protocol operates stably even based on a traditional microcontroller with only 4-kB RAM and 12-MHz system clock, and no communication congestion or frequent packet loss occurs.
Chi-Leung So; Thomas L. Eberhardt
2006-01-01
Differences in bark chemistry between inner and outer bark are well known and may affect the suitability of various bark supplies for a particular application. Accordingly, there is a need for quality control protocols to assess variability and predict product yields. Southern yellow pine bark samples from two industrial sources were separated into inner and outer bark...
Experimental control in software reliability certification
NASA Technical Reports Server (NTRS)
Trammell, Carmen J.; Poore, Jesse H.
1994-01-01
There is growing interest in software 'certification', i.e., confirmation that software has performed satisfactorily under a defined certification protocol. Regulatory agencies, customers, and prospective reusers all want assurance that a defined product standard has been met. In other industries, products are typically certified under protocols in which random samples of the product are drawn, tests characteristic of operational use are applied, analytical or statistical inferences are made, and products meeting a standard are 'certified' as fit for use. A warranty statement is often issued upon satisfactory completion of a certification protocol. This paper outlines specific engineering practices that must be used to preserve the validity of the statistical certification testing protocol. The assumptions associated with a statistical experiment are given, and their implications for statistical testing of software are described.
Rasmussen, Stinne Eika; Nebsbjerg, Mette Amalie; Krogh, Lise Qvirin; Bjørnshave, Katrine; Krogh, Kristian; Povlsen, Jonas Agerlund; Riddervold, Ingunn Skogstad; Grøfte, Thorbjørn; Kirkegaard, Hans; Løfgren, Bo
2017-01-01
Emergency dispatchers use protocols to instruct bystanders in cardiopulmonary resuscitation (CPR). Studies changing one element in the dispatcher's protocol report improved CPR quality. Whether several changes interact is unknown and the effect of combining multiple changes previously reported to improve CPR quality into one protocol remains to be investigated. We hypothesize that a novel dispatch protocol, combining multiple beneficial elements improves CPR quality compared with a standard protocol. A novel dispatch protocol was designed including wording on chest compressions, using a metronome, regular encouragements and a 10-s rest each minute. In a simulated cardiac arrest scenario, laypersons were randomized to perform single-rescuer CPR guided with the novel or the standard protocol. a composite endpoint of time to first compression, hand position, compression depth and rate and hands-off time (maximum score: 22 points). Afterwards participants answered a questionnaire evaluating the dispatcher assistance. The novel protocol (n=61) improved CPR quality score compared with the standard protocol (n=64) (mean (SD): 18.6 (1.4)) points vs. 17.5 (1.7) points, p<0.001. The novel protocol resulted in deeper chest compressions (mean (SD): 58 (12)mm vs. 52 (13)mm, p=0.02) and improved rate of correct hand position (61% vs. 36%, p=0.01) compared with the standard protocol. In both protocols hands-off time was short. The novel protocol improved motivation among rescuers compared with the standard protocol (p=0.002). Participants guided with a standard dispatch protocol performed high quality CPR. A novel bundle of care protocol improved CPR quality score and motivation among rescuers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Wei, Li; Xu, Jian
2018-06-01
Epigenetic factors such as histone modifications play integral roles in plant development and stress response, yet their implications in algae remain poorly understood. In the industrial oleaginous microalgae Nannochloropsis spp., the lack of an efficient methodology for chromatin immunoprecipitation (ChIP), which determines the specific genomic location of various histone modifications, has hindered probing the epigenetic basis of their photosynthetic carbon conversion and storage as oil. Here, a detailed ChIP protocol was developed for Nannochloropsis oceanica, which represents a reliable approach for the analysis of histone modifications, chromatin state, and transcription factor-binding sites at the epigenetic level. Using ChIP-qPCR, genes related to photosynthetic carbon fixation in this microalga were systematically assessed. Furthermore, a ChIP-Seq protocol was established and optimized, which generated a genome-wide profile of histone modification events, using histone mark H3K9Ac as an example. These results are the first step for appreciation of the chromatin landscape in industrial oleaginous microalgae and for epigenetics-based microalgal feedstock development. © 2018 Phycological Society of America.
Gut microbiota in toxicological risk assessment of drugs and chemicals: The need of hour.
Velmurugan, Ganesan
2018-03-06
The advent of industrial revolution caused a large inflow of synthetic chemicals for medical, agricultural, industrial and other purposes in the world. In general, these chemicals were subjected to toxicological risk assessment for human health and ecology before release for public use. But today we are witnessing a negative impact of some of these chemicals on human health and environment indicating an underestimation of toxic effects by current risk assessment protocol. Recent studies established gut microbiota as one of the key player in intercession of toxicity of drugs and synthetic chemicals. Hence, the need of the hour is to include the assessment for microbiota specifically gut microbiota in human toxicological risk assessment protocol. Herewith we are proposing a framework for assessment of gut microbiota upon exposure to drugs or chemicals.
Network time synchronization servers at the US Naval Observatory
NASA Technical Reports Server (NTRS)
Schmidt, Richard E.
1995-01-01
Responding to an increased demand for reliable, accurate time on the Internet and Milnet, the U.S. Naval Observatory Time Service has established the network time servers, tick.usno.navy.mil and tock.usno.navy.mil. The system clocks of these HP9000/747i industrial work stations are synchronized to within a few tens of microseconds of USNO Master Clock 2 using VMEbus IRIG-B interfaces. Redundant time code is available from a VMEbus GPS receiver. UTC(USNO) is provided over the network via a number of protocols, including the Network Time Protocol (NTP) (DARPA Network Working Group Report RFC-1305), the Daytime Protocol (RFC-867), and the Time protocol (RFC-868). Access to USNO network time services is presently open and unrestricted. An overview of USNO time services and results of LAN and WAN time synchronization tests will be presented.
Beard, Brian B.; Kainz, Wolfgang; Onishi, Teruo; Iyama, Takahiro; Watanabe, Soichi; Fujiwara, Osamu; Wang, Jianqing; Bit-Babik, Giorgi; Faraone, Antonio; Wiart, Joe; Christ, Andreas; Kuster, Niels; Lee, Ae-Kyoung; Kroeze, Hugo; Siegbahn, Martin; Keshvari, Jafar; Abrishamkar, Houman; Simon, Winfried; Manteuffel, Dirk; Nikoloski, Neviana
2018-01-01
The specific absorption rates (SAR) determined computationally in the specific anthropomorphic mannequin (SAM) and anatomically correct models of the human head when exposed to a mobile phone model are compared as part of a study organized by IEEE Standards Coordinating Committee 34, SubCommittee 2, and Working Group 2, and carried out by an international task force comprising 14 government, academic, and industrial research institutions. The detailed study protocol defined the computational head and mobile phone models. The participants used different finite-difference time-domain software and independently positioned the mobile phone and head models in accordance with the protocol. The results show that when the pinna SAR is calculated separately from the head SAR, SAM produced a higher SAR in the head than the anatomically correct head models. Also the larger (adult) head produced a statistically significant higher peak SAR for both the 1- and 10-g averages than did the smaller (child) head for all conditions of frequency and position. PMID:29515260
Climate science: Breaks in trends
NASA Astrophysics Data System (ADS)
Pretis, Felix; Allen, Myles
2013-12-01
Global temperature rise since industrialization has not been uniform. A statistical analysis suggests that past changes in the rate of warming can be directly attributed to human influences, from economic downturns to the regulations of the Montreal Protocol.
A Telecommunications Industry Primer: A Systems Model.
ERIC Educational Resources Information Center
Obermier, Timothy R.; Tuttle, Ronald H.
2003-01-01
Describes the Telecommunications Systems Model to help technical educators and students understand the increasingly complex telecommunications infrastructure. Specifically looks at ownership and regulatory status, service providers, transport medium, network protocols, and end-user services. (JOW)
Wireless Communications in Space
NASA Technical Reports Server (NTRS)
2004-01-01
In 1992, NASA and the U.S. Department of Defense jointly commissioned the research and development of a technology solution to address the challenges and requirements of communicating with their spacecraft. The project yielded an international consortium composed of representatives from the space science community, industry, and academia. This group of experts developed a broad suite of protocols specifically designed for space-based communications, known today as Space Communications Protocol Standards (SCPS). Having been internationally standardized by the Consultative Committee on Space Data Systems and the International Standards Organization, SCPS is distributed as open source technology by NASA s Jet Propulsion Laboratory (JPL). The protocols are used for every national space mission that takes place today.
Advanced Communications Technology Satellite Now Operating in an Inclined Orbit
NASA Technical Reports Server (NTRS)
Bauer, Robert A.
1999-01-01
The Advanced Communications Technology Satellite (ACTS) system has been modified to support operation in an inclined orbit that is virtually transparent to users, and plans are to continue this final phase of its operation through September 2000. The next 2 years of ACTS will provide a new opportunity for using the technologies that this system brought online over 5 years ago and that are still being used to resolve the technical issues that face NASA and the satellite industry in the area of seamless networking and interoperability with terrestrial systems. New goals for ACTS have been defined that align the program with recent changes in NASA and industry. ACTS will be used as a testbed to: Show how NASA and other Government agencies can use commercial systems for 1. future support of their operations Test, characterize, and resolve technical issues in using advanced communications 2. protocols such as asynchronous transfer mode (ATM) and transmission control protocol/Internet protocol (TCP/IP) over long latency links as found when interoperating satellites with terrestrial systems Evaluate narrow-spot-beam Ka-band satellite operation in an inclined orbit 3. Verify Ka-band satellite technologies since no other Ka-band system is yet 4. available in the United States
Legacy to Industry 4.0: A Profibus Sniffer
NASA Astrophysics Data System (ADS)
Tsegaye Mamo, Fesseha; Sikora, Axel; Rathfelder, Christoph
2017-07-01
Legacy industrial communication protocols are proved robust and functional. During the last decades, the industry has invented completely new or advanced versions of the legacy communication solutions. However, even with the high adoption rate of these new solutions, still the majority industry applications run on legacy, mostly fieldbus related technologies. Profibus is one of those technologies that still keep on growing in the market, albeit a slow in market growth in recent years. A retrofit technology that would enable these technologies to connect to the Internet of Things, utilize the ever growing potential of data analysis, predictive maintenance or cloud-based application, while at the same time not changing a running system is fundamental.
Bayindir, Ramazan; Cetinceviz, Yucel
2011-04-01
This paper describes a water pumping control system that is designed for production plants and implemented in an experimental setup in a laboratory. These plants contain harsh environments in which chemicals, vibrations or moving parts exist that could potentially damage the cabling or wires that are part of the control system. Furthermore, the data has to be transferred over paths that are accessible to the public. The control systems that it uses are a programmable logic controller (PLC) and industrial wireless local area network (IWLAN) technologies. It is implemented by a PLC, an communication processor (CP), two IWLAN modules, and a distributed input/output (I/O) module, as well as the water pump and sensors. Our system communication is based on an Industrial Ethernet and uses the standard Transport Control Protocol/Internet Protocol for parameterisation, configuration and diagnostics. The main function of the PLC is to send a digital signal to the water pump to turn it on or off, based on the tank level, using a pressure transmitter and inputs from limit switches that indicate the level of the water in the tank. This paper aims to provide a convenient solution in process plants where cabling is not possible. It also has lower installation and maintenance cost, provides reliable operation, and robust and flexible construction, suitable for industrial applications. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.
Performance measures in the earth observations commercialization applications program
NASA Astrophysics Data System (ADS)
Macauley, Molly K.
1996-03-01
Performance measures in the Earth Observations Commercialization Application Program (EOCAP) are key to its success and include net profitability; enhancements to industry productivity through generic innovations in industry practices, standards, and protocols; and documented contributions to public policy governing the newly developing remote sensing industry. Because EOCAP requires company co-funding, both parties to the agreement (the government and the corporate partner) have incentives to pursue these goals. Further strengthening progress towards these goals are requirements for business plans in the company's EOCAP proposal, detailed scrutiny given these plans during proposal selection, and regularly documented progress reports during project implementation.
15 CFR 782.1 - Overview of reporting requirements under the APR.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL... (see § 782.5 of the APR). In addition, forms may be downloaded from the Internet at http://www.ap.gov. ...
15 CFR 782.1 - Overview of reporting requirements under the APR.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL... (see § 782.5 of the APR). In addition, forms may be downloaded from the Internet at http://www.ap.gov. ...
15 CFR 782.1 - Overview of reporting requirements under the APR.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL... (see § 782.5 of the APR). In addition, forms may be downloaded from the Internet at http://www.ap.gov. ...
15 CFR 782.1 - Overview of reporting requirements under the APR.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL... (see § 782.5 of the APR). In addition, forms may be downloaded from the Internet at http://www.ap.gov. ...
15 CFR 783.3 - Reports containing information determined by BIS not to be required by the APR.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS CIVIL NUCLEAR FUEL CYCLE-RELATED ACTIVITIES NOT INVOLVING NUCLEAR MATERIALS...
Quantum Private Comparison of Equality Based on Five-Particle Cluster State
NASA Astrophysics Data System (ADS)
Chang, Yan; Zhang, Wen-Bo; Zhang, Shi-Bin; Wang, Hai-Chun; Yan, Li-Li; Han, Gui-Hua; Sheng, Zhi-Wei; Huang, Yuan-Yuan; Suo, Wang; Xiong, Jin-Xin
2016-12-01
A protocol for quantum private comparison of equality (QPCE) is proposed based on five-particle cluster state with the help of a semi-honest third party (TP). In our protocol, TP is allowed to misbehave on its own but can not conspire with either of two parties. Compared with most two-user QPCE protocols, our protocol not only can compare two groups of private information (each group has two users) in one execution, but also compare just two private information. Compared with the multi-user QPCE protocol proposed, our protocol is safer with more reasonable assumptions of TP. The qubit efficiency is computed and analyzed. Our protocol can also be generalized to the case of 2N participants with one TP. The 2N-participant protocol can compare two groups (each group has N private information) in one execution or just N private information. Supported by NSFC under Grant Nos. 61402058, 61572086, the Fund for Middle and Young Academic Leaders of CUIT under Grant No. J201511, the Science and Technology Support Project of Sichuan Province of China under Grant No. 2013GZX0137, the Fund for Young Persons Project of Sichuan Province of China under Grant No. 12ZB017, and the Foundation of Cyberspace Security Key Laboratory of Sichuan Higher Education Institutions under Grant No. szjj2014-074
Berman, D Wayne
2011-08-01
Given that new protocols for assessing asbestos-related cancer risk have recently been published, questions arise concerning how they compare to the "IRIS" protocol currently used by regulators. The newest protocols incorporate findings from 20 additional years of literature. Thus, differences between the IRIS and newer Berman and Crump protocols are examined to evaluate whether these protocols can be reconciled. Risks estimated by applying these protocols to real exposure data from both laboratory and field studies are also compared to assess the relative health protectiveness of each protocol. The reliability of risks estimated using the two protocols are compared by evaluating the degree with which each potentially reproduces the known epidemiology study risks. Results indicate that the IRIS and Berman and Crump protocols can be reconciled; while environment-specific variation within fiber type is apparently due primarily to size effects (not addressed by IRIS), the 10-fold (average) difference between amphibole asbestos risks estimated using each protocol is attributable to an arbitrary selection of the lowest of available mesothelioma potency factors in the IRIS protocol. Thus, the IRIS protocol may substantially underestimate risk when exposure is primarily to amphibole asbestos. Moreover, while the Berman and Crump protocol is more reliable than the IRIS protocol overall (especially for predicting amphibole risk), evidence is presented suggesting a new fiber-size-related adjustment to the Berman and Crump protocol may ultimately succeed in reconciling the entire epidemiology database. However, additional data need to be developed before the performance of the adjusted protocol can be fully validated. © 2011 Society for Risk Analysis.
Pein, Miriam; Eckert, Carolin; Preis, Maren; Breitkreutz, Jörg
2013-09-01
Performance qualification (PQ) of taste sensing systems is mandatory for their use in pharmaceutical industry. According to ICH Q2 (R1) and a recent adaptation for taste sensing systems, non-specificity, log-linear relationships between the concentration of analytes and the sensor signal as well as a repeatability with relative standard deviation (RSD) values <4% were defined as basic requirements to pass a PQ. In the present work, the αAstree taste sensing system led to a successful PQ procedure by the use of recent sensor batches for pharmaceutical applications (sensor set #2) and a modified measurement protocol. Log-linear relationships between concentration and responses of each sensor were investigated for different bitter tasting active pharmaceutical ingredients (APIs). Using the new protocol, RSD values <2.1% were obtained in the repeatability study. Applying the visual evaluation approach, detection and quantitation limit could be determined for caffeine citrate with every sensor (LOD 0.05-0.5 mM, LOQ: 0.1-0.5 mM). In addition, the sensor set marketed for food applications (sensor set #5) was proven to show beneficial effects regarding the log-linear relationship between the concentration of quinine hydrochloride and the sensor signal. By the use of our proposed protocol, it is possible to implement the αAstree taste sensing system as a tool to assure quality control in the pharmaceutical industry. Copyright © 2013 Elsevier B.V. All rights reserved.
Saade, Charbel; Mayat, Ahmad; El-Merhi, Fadi
2016-01-01
Matching contrast injection timing with vessel dynamics significantly improves vessel opacification and reduces contrast dose in the assessment of pulmonary embolism during computed tomography (CT) pulmonary angiography. The aim of this study was to investigate opacification of the pulmonary vasculature (PV) during CT pulmonary angiography using a patient-specific contrast formula (PSCF) and exponentially decelerated contrast media (EDCM) injection rate. Institutional review board approved this retrospective study. Computed tomography pulmonary angiography was performed on 200 patients with suspected pulmonary embolism using a 64-channel CT scanner. Patient demographics were equally distributed. Patients were randomly assigned to 2 equal protocol groups: protocol A used a PSCF, and protocol B involved the use of a PSCF combined with EDCM. The mean cross-sectional opacification profile of 8 central and 11 peripheral PVs were measured for each patient, and arteriovenous contrast ratio was calculated. Protocols were compared using Mann-Whitney U nonparametric statistics. Jackknife alternative free-response receiver operating characteristic analyses were used to assess diagnostic efficacy. Interobserver variations were investigated using kappa methods. A number of pulmonary arteries demonstrated increases in opacification (P < 0.02) for protocol B compared with A, whereas opacification in all veins was reduced in protocol B (P < 0.03). Subsequently, increased arteriovenous contrast ratio in protocol B compared with A was observed at all anatomic locations (P < 0.0002). An increase in jackknife alternative free-response receiver operating characteristic figure of merit (P < 0.0002) and interobserver variation was observed with protocol B compared with protocol A (κ = 0.3-0.73). Mean contrast volume was reduced in protocol B (29 [4] mL) compared with protocol A (33 [9] mL). Mean effective radiation dose in protocol B (1.2 [0.4] mSv) was reduced by 14% compared with protocol A (1.4 [0.6] mSv). Significant improvements in visualization of the PV can be achieved with a low contrast volume using an EDCM and PSCF. The reduced risk of cancer induction is highlighted.
Validation of Dissolution Testing with Biorelevant Media: An OrBiTo Study.
Mann, James; Dressman, Jennifer; Rosenblatt, Karin; Ashworth, Lee; Muenster, Uwe; Frank, Kerstin; Hutchins, Paul; Williams, James; Klumpp, Lukas; Wielockx, Kristina; Berben, Philippe; Augustijns, Patrick; Holm, Rene; Hofmann, Michael; Patel, Sanjaykumar; Beato, Stefania; Ojala, Krista; Tomaszewska, Irena; Bruel, Jean-Luc; Butler, James
2017-12-04
Dissolution testing with biorelevant media has become widespread in the pharmaceutical industry as a means of better understanding how drugs and formulations behave in the gastrointestinal tract. Until now, however, there have been few attempts to gauge the reproducibility of results obtained with these methods. The aim of this study was to determine the interlaboratory reproducibility of biorelevant dissolution testing, using the paddle apparatus (USP 2). Thirteen industrial and three academic laboratories participated in this study. All laboratories were provided with standard protocols for running the tests: dissolution in FaSSGF to simulate release in the stomach, dissolution in a single intestinal medium, FaSSIF, to simulate release in the small intestine, and a "transfer" (two-stage) protocol to simulate the concentration profile when conditions are changed from the gastric to the intestinal environment. The test products chosen were commercially available ibuprofen tablets and zafirlukast tablets. The biorelevant dissolution tests showed a high degree of reproducibility among the participating laboratories, even though several different batches of the commercially available medium preparation powder were used. Likewise, results were almost identicalbetween the commercial biorelevant media and those produced in-house. Comparing results to previous ring studies, including those performed with USP calibrator tablets or commercially available pharmaceutical products in a single medium, the results for the biorelevant studies were highly reproducible on an interlaboratory basis. Interlaboratory reproducibility with the two-stage test was also acceptable, although the variability was somewhat greater than with the single medium tests. Biorelevant dissolution testing is highly reproducible among laboratories and can be relied upon for cross-laboratory comparisons.
Implementation of WirelessHART in the NS-2 Simulator and Validation of Its Correctness
Zand, Pouria; Mathews, Emi; Havinga, Paul; Stojanovski, Spase; Sisinni, Emiliano; Ferrari, Paolo
2014-01-01
One of the first standards in the wireless sensor networks domain, WirelessHART (HART (Highway Addressable Remote Transducer)), was introduced to address industrial process automation and control requirements. This standard can be used as a reference point to evaluate other wireless protocols in the domain of industrial monitoring and control. This makes it worthwhile to set up a reliable WirelessHART simulator in order to achieve that reference point in a relatively easy manner. Moreover, it offers an alternative to expensive testbeds for testing and evaluating the performance of WirelessHART. This paper explains our implementation of WirelessHART in the NS-2 network simulator. According to our knowledge, this is the first implementation that supports the WirelessHART network manager, as well as the whole stack (all OSI (Open Systems Interconnection model) layers) of the WirelessHART standard. It also explains our effort to validate the correctness of our implementation, namely through the validation of the implementation of the WirelessHART stack protocol and of the network manager. We use sniffed traffic from a real WirelessHART testbed installed in the Idrolab plant for these validations. This confirms the validity of our simulator. Empirical analysis shows that the simulated results are nearly comparable to the results obtained from real networks. We also demonstrate the versatility and usability of our implementation by providing some further evaluation results in diverse scenarios. For example, we evaluate the performance of the WirelessHART network by applying incremental interference in a multi-hop network. PMID:24841245
Secret science: tobacco industry research on smoking behaviour and cigarette toxicity.
Hammond, David; Collishaw, Neil E; Callard, Cynthia
2006-03-04
A lack of scientific data remains the principal obstacle to regulating cigarette toxicity. In particular, there is an immediate need to improve our understanding of the interaction between smoking behaviour and product design, and its influence on cigarette deliveries. This article reviews internal tobacco industry documents on smoking behaviour research undertaken by Imperial Tobacco Limited (ITL) and British-American Tobacco (BAT). BAT documents indicate that smokers vary their puffing behaviour to regulate nicotine levels and compensate for low-yield cigarettes by smoking them more intensely. BAT research also shows that the tar and nicotine delivered to smokers is substantially greater than the machine-smoked yields reported to consumers and regulators. Internal documents describe a strategy to maximise this discrepancy through product design. In particular, BAT developed elastic cigarettes that produced low yields under standard testing protocols, whereas in consumers' hands they elicited more intensive smoking and provided higher concentrations of tar and nicotine to smokers. Documents also show that BAT pursued this product strategy despite the health risks to consumers and ethical concerns raised by senior scientists, and paired it with an equally successful marketing campaign that promoted these cigarettes as low-tar alternatives for health-concerned smokers. Overall, the documents seem to reveal a product strategy intended to exploit the limitations of the testing protocols and to intentionally conceal from consumers and regulators the potential toxicity of BAT products revealed by BAT's own research. Tobacco industry research underscores the serious limitations of the current cigarette testing protocols and the documents describe deceptive business practices that remain in place.
Parel, I; Cutti, A G; Kraszewski, A; Verni, G; Hillstrom, H; Kontaxis, A
2014-03-01
Multi-center clinical trials incorporating shoulder kinematics are currently uncommon. The absence of repeatability and limits of agreement (LoA) studies between different centers employing different motion analysis protocols has led to a lack dataset compatibility. Therefore, the aim of this work was to determine the repeatability and LoA between two shoulder kinematic protocols. The first one uses a scapula tracker (ST), the International Society of Biomechanics anatomical frames and an optoelectronic measurement system, and the second uses a spine tracker, the INAIL Shoulder and Elbow Outpatient protocol (ISEO) and an inertial and magnetic measurement system. First within-protocol repeatability for each approach was assessed on a group of 23 healthy subjects and compared with the literature. Then, the between-protocol agreement was evaluated. The within-protocol repeatability was similar for the ST ([Formula: see text] = 2.35°, [Formula: see text] = 0.97°, SEM = 2.5°) and ISEO ([Formula: see text] = 2.24°, [Formula: see text] = 0.97°, SEM = 2.3°) protocols and comparable with data from published literature. The between-protocol agreement analysis showed comparable scapula medio-lateral rotation measurements for up to 120° of flexion-extension and up to 100° of scapula plane ab-adduction. Scapula protraction-retraction measurements were in agreement for a smaller range of humeral elevation. The results of this study suggest comparable repeatability for the ST and ISEO protocols and between-protocol agreement for two scapula rotations. Different thresholds for repeatability and LoA may be adapted to suit different clinical hypotheses.
Wallace, Adam N; Vyhmeister, Ross; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; Ramirez-Giraldo, Juan Carlos; McKinstry, Robert C
2015-06-01
Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality.
Oldrini, Guillaume; Fedida, Benjamin; Poujol, Julie; Felblinger, Jacques; Trop, Isabelle; Henrot, Philippe; Darai, Emile; Thomassin-Naggara, Isabelle
2017-10-01
To evaluate the added value of ULTRAFAST-MR sequence to an abbreviated FAST protocol in comparison with FULL protocol to distinguish benign from malignant lesions in a population of women, regardless of breast MR imaging indication. From March 10th to September 22th, 2014, we retrospectively included a total of 70 consecutive patients with 106 histologically proven lesions (58 malignant and 48 benign) who underwent breast MR imaging for preoperative breast staging (n=38), high-risk screening (n=7), problem solving (n=18), and nipple discharge (n=4) with 12 time resolved imaging of contrast kinetics (TRICKS) acquisitions during contrast inflow interleaved in a regular high-resolution dynamic MRI protocol (FULL protocol). Two readers scored MR exams as either positive or negative and described significant lesions according to Bi-RADS lexicon with a TRICKS images (ULTRAFAST), an abbreviated protocol (FAST) and all images (FULL protocol). Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated for each protocol and compared with McNemar's test. For all readers, the combined FAST-ULTRAFAST protocol significantly improved the reading with a specificity of 83.3% and 70.8% in comparison with FAST protocol or FULL protocol, respectively, without change in sensitivity. By adding ULTRAFAST protocol to FAST protocol, readers 1 and 2 were able to correctly change the diagnosis in 22.9% (11/48) and 10.4% (5/48) of benign lesions, without missing any malignancy, respectively. Both interpretation and image acquisition times for combined FAST-ULTRAFAST protocol and FAST protocol were shorter compared to FULL protocol (p<0.001). Compared to FULL protocol, adding ULTRAFAST to FAST protocol improves specificity, mainly in correctly reclassifying benign masses and reducing interpretation and acquisition time, without decreasing sensitivity. Copyright © 2017 Elsevier B.V. All rights reserved.
Job Prospects for Manufacturing Engineers.
ERIC Educational Resources Information Center
Basta, Nicholas
1985-01-01
Coming from a variety of disciplines, manufacturing engineers are keys to industry's efforts to modernize, with demand exceeding supply. The newest and fastest-growing areas include machine vision, composite materials, and manufacturing automation protocols, each of which is briefly discussed. (JN)
48 CFR 204.470-3 - Contract clause.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., DEPARTMENT OF DEFENSE GENERAL ADMINISTRATIVE MATTERS Safeguarding Classified Information Within Industry 204... Protocol, in solicitations and contracts for research and development or major defense acquisition programs...) Other radiological source materials; or (c) Technologies directly related to nuclear power production...
48 CFR 204.470-3 - Contract clause.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., DEPARTMENT OF DEFENSE GENERAL ADMINISTRATIVE MATTERS Safeguarding Classified Information Within Industry 204... Protocol, in solicitations and contracts for research and development or major defense acquisition programs...) Other radiological source materials; or (c) Technologies directly related to nuclear power production...
48 CFR 204.470-3 - Contract clause.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF DEFENSE GENERAL ADMINISTRATIVE MATTERS Safeguarding Classified Information Within Industry 204... Protocol, in solicitations and contracts for research and development or major defense acquisition programs...) Other radiological source materials; or (c) Technologies directly related to nuclear power production...
48 CFR 204.470-3 - Contract clause.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., DEPARTMENT OF DEFENSE GENERAL ADMINISTRATIVE MATTERS Safeguarding Classified Information Within Industry 204... Protocol, in solicitations and contracts for research and development or major defense acquisition programs...) Other radiological source materials; or (c) Technologies directly related to nuclear power production...
Assessing Metal Mobilization from Industrially Lead-Contaminated Soils Located at an Urban Site
A series of leaching and partitioning tests (Toxicity Characteristic Leaching Procedure (TCLP), Synthetic Precipitation Leaching Procedure (SPLP), Controlled Acidity Leaching Protocol (CALP), Acid Neutralization Capacity (ANC), and sequential extraction) were applied to three dif...
Chetty, C C; Rossin, C B; Gruissem, W; Vanderschuren, H; Rey, M E C
2013-01-25
Knowledge and technology transfer to African laboratories and farmers is an important objective for achieving food security and sustainable crop production on the sub-Saharan African continent. Cassava (Manihot esculenta Crantz) is a vital source of calories for more than a billion people in developing countries, and its potential industrial use for starch and bioethanol in the tropics is increasingly being recognized. However, cassava production remains constrained by the susceptibility of the crop to several biotic and abiotic stresses. For more than a decade, biotechnology has been considered an attractive tool to improve cassava as it substantially circumvents the limitations of traditional breeding, which is particularly time-consuming and tedious because of the high heterozygosity of the crop. A major constraint to the development of biotechnological approaches for cassava improvement has been the lack of an efficient and robust transformation and regeneration system. Despite some success achieved in genetic modification of the model cassava cultivar Tropical Manihot Series (TMS), TMS 60444, in some European and U.S. laboratories, the lack of a reproducible and robust protocol has not allowed the establishment of a routine transformation system in sub-Saharan Africa. In this study, we optimized a robust and efficient protocol developed at ETH Zurich to successfully establish transformation of a commercially cultivated South African landrace, T200, and compared this with the benchmark model cultivar TMS 60444. Results from our study demonstrated high transformation rates for both T200 (23 transgenic lines from 100 friable embryogenic callus (FEC) clusters) compared with TMS 60444 (32 transgenic lines from 100 FEC clusters). The success in transforming landraces or farmer-preferred cultivars has been limited, and the high transformation rate of an industry-preferred landrace in this study is encouraging for a feasible transformation program for cassava improvement in South Africa (SA), which can potentially be extended to other countries in southern Africa. The successful establishment of a robust cassava transformation and regeneration system in SA demonstrates the relevance of technology transfer to sub-Saharan Africa and highlights the importance of developing suitable and reliable techniques before their transfer to laboratories offering less optimal conditions. Copyright © 2012 Elsevier B.V. All rights reserved.
[Impact of the economic crisis on the activity of a clinical research ethics committee].
Redondo Capafons, S; Arcenillas, Paula; Giménez, Nuria; March López, Pablo; Soriano, Laura; Pla, Ramon; Quintana, Salvador
2014-11-03
Analyze the impact of economic and social crisis in volume and funding of clinical trials (CT) and observational studies (ES) from the activity of an Research Ethics Committee (REC). REC memories 2003-2012 were reviewed. Financing of evaluated projects, CT and OS were analyzed classifying them into four groups: 1) promoted by pharmaceutical industry, 2) by scientific societies with industry support, 3) by scientific societies with government support and 4) unfunding.Two periods were compared: pre-crisis (2003-2007) and crisis (2008-2012). During 10 studied years, 744 protocols were evaluated: a 71% of group 1, a 9% of group 2, a 3% of group 3 and a 17% was no funding. Regarding OS, 40%, 5,4%, 8,6% and 46% were the groups 1, 2, 3 and 4 respectively. Analyzing crisis versus pre-crisis period, statistically significant differences were observed in the decreasing of number of CT phase 2 and 3 and in the rising EO. Comparing crisis related to the pre-crisis period, the Group 4 increased statistically significantly. Evolution of total number of studies evaluated by REC tends to be maintained and even increased over time. REC maintains its activity and even increased at the expense of financing and unfunded OS. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Hawley, Philippa Helen; Byeon, Jai Jun
2008-05-01
Constipation is a common and distressing condition in patients with cancer, especially those taking opioid analgesics. Many institutions prevent and treat constipation with titrated laxatives, which is known as a bowel protocol. An effective and well-tolerated bowel protocol is a very important component of cancer care, and there is little evidence on which to base selection of the most appropriate agents. This study compares a protocol of the stimulant laxative sennosides alone with a protocol of sennosides plus the stool softener docusate, in hospitalized patients at an oncology center. The docusate-containing protocol had an initial docusate-only step for patients not taking opioids, and four to six 100-mg capsules of docusate sodium in addition to the sennosides for the rest of the protocol. Thirty patients received the sennosides-only (S) protocol and 30 the sennosides plus docusate (DS) protocol. The efficacy and adverse effects of the protocols were monitored for 5-12 days. The two protocols were used sequentially, creating two cohorts, one on each protocol. Eighty percent of patients were taking oral opioids and 72% were admitted for symptom control/supportive care. Over a total of 488 days of observation it was found that the S protocol produced more bowel movements than the DS protocol, and in the symptom control/supportive care patients this difference was statistically significant (p < 0.05). In the S group admitted for symptom control/supportive care 62.5% had a bowel movement more than 50% of days, as compared with 32% in those receiving the DS protocol. Fifty-seven percent of the DS group required additional interventions (lactulose, suppositories or enemas) compared to 40% in the S group. Cramps were reported equally by 3 (10%) patients in each group. Eight patients (27%) experienced diarrhea in the S group compared to 4 (13%) in the DS group. The addition of the initial docusate-only step and adding docusate 400-600 mg/d to the sennosides did not reduce bowel cramps, and was less effective in inducing laxation than the sennosides-only protocol. Further research into the appropriate use of docusate and into the details of bowel protocol design are required.
An Architecture for SCADA Network Forensics
NASA Astrophysics Data System (ADS)
Kilpatrick, Tim; Gonzalez, Jesus; Chandia, Rodrigo; Papa, Mauricio; Shenoi, Sujeet
Supervisory control and data acquisition (SCADA) systems are widely used in industrial control and automation. Modern SCADA protocols often employ TCP/IP to transport sensor data and control signals. Meanwhile, corporate IT infrastructures are interconnecting with previously isolated SCADA networks. The use of TCP/IP as a carrier protocol and the interconnection of IT and SCADA networks raise serious security issues. This paper describes an architecture for SCADA network forensics. In addition to supporting forensic investigations of SCADA network incidents, the architecture incorporates mechanisms for monitoring process behavior, analyzing trends and optimizing plant performance.
Matta, Ragai-Edward; von Wilmowsky, Cornelius; Neuhuber, Winfried; Lell, Michael; Neukam, Friedrich W; Adler, Werner; Wichmann, Manfred; Bergauer, Bastian
2016-05-01
Multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT) are indispensable imaging techniques in advanced medicine. The possibility of creating virtual and corporal three-dimensional (3D) models enables detailed planning in craniofacial and oral surgery. The objective of this study was to evaluate the impact of different scan protocols for CBCT and MSCT on virtual 3D model accuracy using a software-based evaluation method that excludes human measurement errors. MSCT and CBCT scans with different manufacturers' predefined scan protocols were obtained from a human lower jaw and were superimposed with a master model generated by an optical scan of an industrial noncontact scanner. To determine the accuracy, the mean and standard deviations were calculated, and t-tests were used for comparisons between the different settings. Averaged over 10 repeated X-ray scans per method and 19 measurement points per scan (n = 190), it was found that the MSCT scan protocol 140 kV delivered the most accurate virtual 3D model, with a mean deviation of 0.106 mm compared to the master model. Only the CBCT scans with 0.2-voxel resolution delivered a similar accurate 3D model (mean deviation 0.119 mm). Within the limitations of this study, it was demonstrated that the accuracy of a 3D model of the lower jaw depends on the protocol used for MSCT and CBCT scans. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Jeziorowska, Dorota; Fontaine, Vincent; Jouve, Charlène; Villard, Eric; Dussaud, Sébastien; Akbar, David; Letang, Valérie; Cervello, Pauline; Itier, Jean-Michiel; Pruniaux, Marie-Pierre; Hulot, Jean-Sébastien
2017-01-01
Human induced pluripotent stem cells (iPSCs) represent a powerful human model to study cardiac disease in vitro, notably channelopathies and sarcomeric cardiomyopathies. Different protocols for cardiac differentiation of iPSCs have been proposed either based on embroid body formation (3D) or, more recently, on monolayer culture (2D). We performed a direct comparison of the characteristics of the derived cardiomyocytes (iPSC-CMs) on day 27 ± 2 of differentiation between 3D and 2D differentiation protocols with two different Wnt-inhibitors were compared: IWR1 (inhibitor of Wnt response) or IWP2 (inhibitor of Wnt production). We firstly found that the level of Troponin T (TNNT2) expression measured by FACS was significantly higher for both 2D protocols as compared to the 3D protocol. In the three methods, iPSC-CM show sarcomeric structures. However, iPSC-CM generated in 2D protocols constantly displayed larger sarcomere lengths as compared to the 3D protocol. In addition, mRNA and protein analyses reveal higher cTNi to ssTNi ratios in the 2D protocol using IWP2 as compared to both other protocols, indicating a higher sarcomeric maturation. Differentiation of cardiac myocytes with 2D monolayer-based protocols and the use of IWP2 allows the production of higher yield of cardiac myocytes that have more suitable characteristics to study sarcomeric cardiomyopathies. PMID:28587156
Vassalou, Evangelia E; Raissaki, Maria; Magkanas, Eleftherios; Antoniou, Katerina M; Karantanas, Apostolos H
2018-03-01
To compare a simplified ultrasonographic (US) protocol in 2 patient positions with the same-positioned comprehensive US assessments and high-resolution computed tomographic (CT) findings in patients with idiopathic pulmonary fibrosis. Twenty-five consecutive patients with idiopathic pulmonary fibrosis were prospectively enrolled and examined in 2 sessions. During session 1, patients were examined with a US protocol including 56 lung intercostal spaces in supine/sitting (supine/sitting comprehensive protocol) and lateral decubitus (decubitus comprehensive protocol) positions. During session 2, patients were evaluated with a 16-intercostal space US protocol in sitting (sitting simplified protocol) and left/right decubitus (decubitus simplified protocol) positions. The 16 intercostal spaces were chosen according to the prevalence of idiopathic pulmonary fibrosis-related changes on high-resolution CT. The sum of B-lines counted in each intercostal space formed the US scores for all 4 US protocols: supine/sitting and decubitus comprehensive US scores and sitting and decubitus simplified US scores. High-resolution CT-related Warrick scores (J Rheumatol 1991; 18:1520-1528) were compared to US scores. The duration of each protocol was recorded. A significant correlation was found between all US scores and Warrick scores and between simplified and corresponding comprehensive scores (P < .0001). Decubitus simplified US scores showed a slightly higher correlation with Warrick scores compared to sitting simplified US scores. Mean durations of decubitus and sitting simplified protocols were 4.76 and 6.20 minutes, respectively (P < .005). Simplified 16-intercostal space protocols correlated with comprehensive protocols and high-resolution CT findings in patients with idiopathic pulmonary fibrosis. The 16-intercostal space simplified protocol in the lateral decubitus position correlated better with high-resolution CT findings and was less time-consuming compared to the sitting position. © 2017 by the American Institute of Ultrasound in Medicine.
Past, Present, and Future Industrial Biotechnology in China
NASA Astrophysics Data System (ADS)
Li, Zhenjiang; Ji, Xiaojun; Kan, Suli; Qiao, Hongqun; Jiang, Min; Lu, Dingqiang; Wang, Jun; Huang, He; Jia, Honghua; Ouyuang, Pingkai; Ying, Hanjie
Fossil resources, i.e. concentrated carbon from biomass, have been irrecoverably exhausted through modern industrial civilization in the last two hundred years. Serious consequences including crises in resources, environment and energy, as well as the pressing need for direct and indirect exploitation of solar energy, pose challenges to the science and technology community of today. Bioenergy, bulk chemicals, and biomaterials could be produced from renewable biomass in a biorefinery via biocatalysis. These sustainable industries will match the global mass cycle, creating a new form of civilization with new industries and agriculture driven by solar energy. Industrial biotechnology is the dynamo of a bioeconomy, leading to a new protocol for production of energy, bulk chemicals, and materials. This new mode of innovation will place the industry at center stage supported by universities and research institutes. Creativity in industrial biotechnology will be promoted and China will successfully follow the road to green modernization. China's rapid economic development and its traditional capacity in fermentation will place it in an advantageous position in the industrial biotechnology revolution. The development and current status of industrial biotechnology in China are summarized herein.
Past, present, and future industrial biotechnology in China.
Li, Zhenjiang; Ji, Xiaojun; Kan, Suli; Qiao, Hongqun; Jiang, Min; Lu, Dingqiang; Wang, Jun; Huang, He; Jia, Honghua; Ouyuang, Pingkai; Ying, Hanjie
2010-01-01
Fossil resources, i.e. concentrated carbon from biomass, have been irrecoverably exhausted through modern industrial civilization in the last two hundred years. Serious consequences including crises in resources, environment and energy, as well as the pressing need for direct and indirect exploitation of solar energy, pose challenges to the science and technology community of today. Bioenergy, bulk chemicals, and biomaterials could be produced from renewable biomass in a biorefinery via biocatalysis. These sustainable industries will match the global mass cycle, creating a new form of civilization with new industries and agriculture driven by solar energy. Industrial biotechnology is the dynamo of a bioeconomy, leading to a new protocol for production of energy, bulk chemicals, and materials. This new mode of innovation will place the industry at center stage supported by universities and research institutes. Creativity in industrial biotechnology will be promoted and China will successfully follow the road to green modernization. China's rapid economic development and its traditional capacity in fermentation will place it in an advantageous position in the industrial biotechnology revolution. The development and current status of industrial biotechnology in China are summarized herein.
PCR on yeast colonies: an improved method for glyco-engineered Saccharomyces cerevisiae
2013-01-01
Background Saccharomyces cerevisiae is extensively used in bio-industries. However, its genetic engineering to introduce new metabolism pathways can cause unexpected phenotypic alterations. For example, humanisation of the glycosylation pathways is a high priority pharmaceutical industry goal for production of therapeutic glycoproteins in yeast. Genomic modifications can lead to several described physiological changes: biomass yields decrease, temperature sensitivity or cell wall structure modifications. We have observed that deletion of several N-mannosyltransferases in Saccharomyces cerevisiae, results in strains that can no longer be analyzed by classical PCR on yeast colonies. Findings In order to validate our glyco-engineered Saccharomyces cerevisiae strains, we developed a new protocol to carry out PCR directly on genetically modified yeast colonies. A liquid culture phase, combined with the use of a Hot Start DNA polymerase, allows a 3-fold improvement of PCR efficiency. The results obtained are repeatable and independent of the targeted sequence; as such the protocol is well adapted for intensive screening applications. Conclusions The developed protocol enables by-passing of many of the difficulties associated with PCR caused by phenotypic modifications brought about by humanisation of the glycosylation in yeast and allows rapid validation of glyco-engineered Saccharomyces cerevisiae cells. It has the potential to be extended to other yeast strains presenting cell wall structure modifications. PMID:23688076
NASA Astrophysics Data System (ADS)
Xu, Ling; Zhao, Zhiwen
2017-12-01
Quantum private comparison (QPC) protocol, including Alice, Bob and the third party Charlie, aims at comparing Alice and Bob's secret inputs correctly without leaking them. Firstly, χ ^+ state and W-Class state are used to conduct the entanglement swapping in this protocol. Either the basis {|φ ^± > ,|ψ ^± >} or the basis {|χ ^± > ,|ω ^± > } is chosen by Alice and Bob based on the predetermined value to measure the particle pairs. And three bits of secret inputs can be compared in this protocol in every comparison time, while most of previous QPC protocols can only compare one or two bits. The qubit efficiency of this protocol is 60% more than others, which are 50% at most. Secondly, if the eavesdropper intends to obtain the secret inputs, it is important and primary to get the measurement results of particle pairs. In this protocol, even if the eavesdropper gets the accurate particle pairs, he cannot get the right measurement results without the right basis. Finally, this protocol is analyzed to be able to defend the secret inputs against various kinds of attack.
Gabr, Mahmoud M; Zakaria, Mahmoud M; Refaie, Ayman F; Khater, Sherry M; Ashamallah, Sylvia A; Ismail, Amani M; El-Badri, Nagwa; Ghoneim, Mohamed A
2014-01-01
Many protocols were utilized for directed differentiation of mesenchymal stem cells (MSCs) to form insulin-producing cells (IPCs). We compared the relative efficiency of three differentiation protocols. Human bone marrow-derived MSCs (HBM-MSCs) were obtained from three insulin-dependent type 2 diabetic patients. Differentiation into IPCs was carried out by three protocols: conophylline-based (one-step protocol), trichostatin-A-based (two-step protocol), and β -mercaptoethanol-based (three-step protocol). At the end of differentiation, cells were evaluated by immunolabeling for insulin production, expression of pancreatic endocrine genes, and release of insulin and c-peptide in response to increasing glucose concentrations. By immunolabeling, the proportion of generated IPCs was modest ( ≃ 3%) in all the three protocols. All relevant pancreatic endocrine genes, insulin, glucagon, and somatostatin, were expressed. There was a stepwise increase in insulin and c-peptide release in response to glucose challenge, but the released amounts were low when compared with those of pancreatic islets. The yield of functional IPCs following directed differentiation of HBM-MSCs was modest and was comparable among the three tested protocols. Protocols for directed differentiation of MSCs need further optimization in order to be clinically meaningful. To this end, addition of an extracellular matrix and/or a suitable template should be attempted.
Piletska, Elena V; Karim, Kal; Cutler, Malcolm; Piletsky, Sergey A
2013-01-01
A polymeric adsorbent for extraction of the antimalarial drug artemisinin from Artemisia annua L. was computationally designed. This polymer demonstrated a high capacity for artemisinin (120 mg g(-1) ), quantitative recovery (87%) and was found to be an effective material for purification of artemisinin from complex plant matrix. The artemisinin quantification was conducted using an optimised HPLC-MS protocol, which was characterised by high precision and linearity in the concentration range between 0.05 and 2 μg mL(-1) . Optimisation of the purification protocol also involved screening of commercial adsorbents for the removal of waxes and other interfering natural compounds, which inhibit the crystallisation of artemisinin. As a result of a two step-purification protocol crystals of artemisinin were obtained, and artemisinin purity was evaluated as 75%. By performing the second stage of purification twice, the purity of artemisinin can be further improved to 99%. The developed protocol produced high-purity artemisinin using only a few purification steps that makes it suitable for large scale industrial manufacturing process. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A secure RFID authentication protocol adopting error correction code.
Chen, Chien-Ming; Chen, Shuai-Min; Zheng, Xinying; Chen, Pei-Yu; Sun, Hung-Min
2014-01-01
RFID technology has become popular in many applications; however, most of the RFID products lack security related functionality due to the hardware limitation of the low-cost RFID tags. In this paper, we propose a lightweight mutual authentication protocol adopting error correction code for RFID. Besides, we also propose an advanced version of our protocol to provide key updating. Based on the secrecy of shared keys, the reader and the tag can establish a mutual authenticity relationship. Further analysis of the protocol showed that it also satisfies integrity, forward secrecy, anonymity, and untraceability. Compared with other lightweight protocols, the proposed protocol provides stronger resistance to tracing attacks, compromising attacks and replay attacks. We also compare our protocol with previous works in terms of performance.
A Secure RFID Authentication Protocol Adopting Error Correction Code
Zheng, Xinying; Chen, Pei-Yu
2014-01-01
RFID technology has become popular in many applications; however, most of the RFID products lack security related functionality due to the hardware limitation of the low-cost RFID tags. In this paper, we propose a lightweight mutual authentication protocol adopting error correction code for RFID. Besides, we also propose an advanced version of our protocol to provide key updating. Based on the secrecy of shared keys, the reader and the tag can establish a mutual authenticity relationship. Further analysis of the protocol showed that it also satisfies integrity, forward secrecy, anonymity, and untraceability. Compared with other lightweight protocols, the proposed protocol provides stronger resistance to tracing attacks, compromising attacks and replay attacks. We also compare our protocol with previous works in terms of performance. PMID:24959619
Evaluation of a continuous-rotation, high-speed scanning protocol for micro-computed tomography.
Kerl, Hans Ulrich; Isaza, Cristina T; Boll, Hanne; Schambach, Sebastian J; Nolte, Ingo S; Groden, Christoph; Brockmann, Marc A
2011-01-01
Micro-computed tomography is used frequently in preclinical in vivo research. Limiting factors are radiation dose and long scan times. The purpose of the study was to compare a standard step-and-shoot to a continuous-rotation, high-speed scanning protocol. Micro-computed tomography of a lead grid phantom and a rat femur was performed using a step-and-shoot and a continuous-rotation protocol. Detail discriminability and image quality were assessed by 3 radiologists. The signal-to-noise ratio and the modulation transfer function were calculated, and volumetric analyses of the femur were performed. The radiation dose of the scan protocols was measured using thermoluminescence dosimeters. The 40-second continuous-rotation protocol allowed a detail discriminability comparable to the step-and-shoot protocol at significantly lower radiation doses. No marked differences in volumetric or qualitative analyses were observed. Continuous-rotation micro-computed tomography significantly reduces scanning time and radiation dose without relevantly reducing image quality compared with a normal step-and-shoot protocol.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Decisions. 785.16 Section 785.16 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.16...
Advances Made in the Next Generation of Satellite Networks
NASA Technical Reports Server (NTRS)
Bhasin, Kul B.
1999-01-01
Because of the unique networking characteristics of communications satellites, global satellite networks are moving to the forefront in enhancing national and global information infrastructures. Simultaneously, broadband data services, which are emerging as the major market driver for future satellite and terrestrial networks, are being widely acknowledged as the foundation for an efficient global information infrastructure. In the past 2 years, various task forces and working groups around the globe have identified pivotal topics and key issues to address if we are to realize such networks in a timely fashion. In response, industry, government, and academia undertook efforts to address these topics and issues. A workshop was organized to provide a forum to assess the current state-of-the-art, identify key issues, and highlight the emerging trends in the next-generation architectures, data protocol development, communication interoperability, and applications. The Satellite Networks: Architectures, Applications, and Technologies Workshop was hosted by the Space Communication Program at the NASA Lewis Research Center in Cleveland, Ohio. Nearly 300 executives and technical experts from academia, industry, and government, representing the United States and eight other countries, attended the event (June 2 to 4, 1998). The program included seven panels and invited sessions and nine breakout sessions in which 42 speakers presented on technical topics. The proceedings covers a wide range of topics: access technology and protocols, architectures and network simulations, asynchronous transfer mode (ATM) over satellite networks, Internet over satellite networks, interoperability experiments and applications, multicasting, NASA interoperability experiment programs, NASA mission applications, and Transmission Control Protocol/Internet Protocol (TCP/IP) over satellite: issues, relevance, and experience.
Shahzad, Aamir; Lee, Malrey; Xiong, Neal Naixue; Jeong, Gisung; Lee, Young-Keun; Choi, Jae-Young; Mahesar, Abdul Wheed; Ahmad, Iftikhar
2016-01-01
In Industrial systems, Supervisory control and data acquisition (SCADA) system, the pseudo-transport layer of the distributed network protocol (DNP3) performs the functions of the transport layer and network layer of the open systems interconnection (OSI) model. This study used a simulation design of water pumping system, in-which the network nodes are directly and wirelessly connected with sensors, and are monitored by the main controller, as part of the wireless SCADA system. This study also intends to focus on the security issues inherent in the pseudo-transport layer of the DNP3 protocol. During disassembly and reassembling processes, the pseudo-transport layer keeps track of the bytes sequence. However, no mechanism is available that can verify the message or maintain the integrity of the bytes in the bytes received/transmitted from/to the data link layer or in the send/respond from the main controller/sensors. To properly and sequentially keep track of the bytes, a mechanism is required that can perform verification while bytes are received/transmitted from/to the lower layer of the DNP3 protocol or the send/respond to/from field sensors. For security and byte verification purposes, a mechanism needs to be proposed for the pseudo-transport layer, by employing cryptography algorithm. A dynamic choice security buffer (SB) is designed and employed during the security development. To achieve the desired goals of the proposed study, a pseudo-transport layer stack model is designed using the DNP3 protocol open library and the security is deployed and tested, without changing the original design. PMID:26950129
Shahzad, Aamir; Lee, Malrey; Xiong, Neal Naixue; Jeong, Gisung; Lee, Young-Keun; Choi, Jae-Young; Mahesar, Abdul Wheed; Ahmad, Iftikhar
2016-03-03
In Industrial systems, Supervisory control and data acquisition (SCADA) system, the pseudo-transport layer of the distributed network protocol (DNP3) performs the functions of the transport layer and network layer of the open systems interconnection (OSI) model. This study used a simulation design of water pumping system, in-which the network nodes are directly and wirelessly connected with sensors, and are monitored by the main controller, as part of the wireless SCADA system. This study also intends to focus on the security issues inherent in the pseudo-transport layer of the DNP3 protocol. During disassembly and reassembling processes, the pseudo-transport layer keeps track of the bytes sequence. However, no mechanism is available that can verify the message or maintain the integrity of the bytes in the bytes received/transmitted from/to the data link layer or in the send/respond from the main controller/sensors. To properly and sequentially keep track of the bytes, a mechanism is required that can perform verification while bytes are received/transmitted from/to the lower layer of the DNP3 protocol or the send/respond to/from field sensors. For security and byte verification purposes, a mechanism needs to be proposed for the pseudo-transport layer, by employing cryptography algorithm. A dynamic choice security buffer (SB) is designed and employed during the security development. To achieve the desired goals of the proposed study, a pseudo-transport layer stack model is designed using the DNP3 protocol open library and the security is deployed and tested, without changing the original design.
Demonstration-Scale High-Cell-Density Fermentation of Pichia pastoris.
Liu, Wan-Cang; Zhu, Ping
2018-01-01
Pichia pastoris has been one of the most successful heterologous overexpression systems in generating proteins for large-scale production through high-cell-density fermentation. However, optimizing conditions of the large-scale high-cell-density fermentation for biochemistry and industrialization is usually a laborious and time-consuming process. Furthermore, it is often difficult to produce authentic proteins in large quantities, which is a major obstacle for functional and structural features analysis and industrial application. For these reasons, we have developed a protocol for efficient demonstration-scale high-cell-density fermentation of P. pastoris, which employs a new methanol-feeding strategy-biomass-stat strategy and a strategy of increased air pressure instead of pure oxygen supplement. The protocol included three typical stages of glycerol batch fermentation (initial culture phase), glycerol fed-batch fermentation (biomass accumulation phase), and methanol fed-batch fermentation (induction phase), which allows direct online-monitoring of fermentation conditions, including broth pH, temperature, DO, anti-foam generation, and feeding of glycerol and methanol. Using this protocol, production of the recombinant β-xylosidase of Lentinula edodes origin in 1000-L scale fermentation can be up to ~900 mg/L or 9.4 mg/g cells (dry cell weight, intracellular expression), with the specific production rate and average specific production of 0.1 mg/g/h and 0.081 mg/g/h, respectively. The methodology described in this protocol can be easily transferred to other systems, and eligible to scale up for a large number of proteins used in either the scientific studies or commercial purposes.
A routing protocol based on energy and link quality for Internet of Things applications.
Machado, Kássio; Rosário, Denis; Cerqueira, Eduardo; Loureiro, Antonio A F; Neto, Augusto; Souza, José Neuman de
2013-02-04
The Internet of Things (IoT) is attracting considerable attention from the universities, industries, citizens and governments for applications, such as healthcare, environmental monitoring and smart buildings. IoT enables network connectivity between smart devices at all times, everywhere, and about everything. In this context, Wireless Sensor Networks (WSNs) play an important role in increasing the ubiquity of networks with smart devices that are low-cost and easy to deploy. However, sensor nodes are restricted in terms of energy, processing and memory. Additionally, low-power radios are very sensitive to noise, interference and multipath distortions. In this context, this article proposes a routing protocol based on Routing by Energy and Link quality (REL) for IoT applications. To increase reliability and energy-efficiency, REL selects routes on the basis of a proposed end-to-end link quality estimator mechanism, residual energy and hop count. Furthermore, REL proposes an event-driven mechanism to provide load balancing and avoid the premature energy depletion of nodes/networks. Performance evaluations were carried out using simulation and testbed experiments to show the impact and benefits of REL in small and large-scale networks. The results show that REL increases the network lifetime and services availability, as well as the quality of service of IoT applications. It also provides an even distribution of scarce network resources and reduces the packet loss rate, compared with the performance of well-known protocols.
Mupparapu, Muralidhar
2008-03-01
Voice over Internet protocol (VoIP) is a revolutionary new technology that is causing a stir in the telecommunications industry and threatening the existence of traditional telephone service providers. Based on a simple method of converting analog audio signals into digital data before being transmitted over the Internet, VoIP has gained immense popularity among consumers. The technology is now regarded as an alternative to traditional telephone service for the orthodontic office. When the economics are considered, it is cost-effective, especially for a busy orthodontic practice where the call volumes both in and out are always high. VoIP has the potential to reduce costs, break the barriers between local vs long-distance calling, and make life easier for the office staff. However, deploying VoIP requires a cautious and thought-out process. Users should fully understand the risks and benefits before switching from the public switched telephone network. VoIP customers and service providers are vulnerable to many of the same impersonation-based attacks by those who attempt toll fraud, and identity and information theft. In this article, VoIP is introduced to orthodontic practitioners, who might be unfamiliar with this technology. Internet protocol based private branch exchange systems that are currently marketed as open-source technologies are also reviewed. Additionally, VoIP is compared with the traditional public switched telephone network technology and evaluated for its potential applications in an orthodontic office for both increased efficiency and cost savings.
A Routing Protocol Based on Energy and Link Quality for Internet of Things Applications
Machado, Kassio; Rosário, Denis; Cerqueira, Eduardo; Loureiro, Antonio A. F.; Neto, Augusto; de Souza, José Neuman
2013-01-01
The Internet of Things (IoT) is attracting considerable attention from the universities, industries, citizens and governments for applications, such as healthcare,environmental monitoring and smart buildings. IoT enables network connectivity between smart devices at all times, everywhere, and about everything. In this context, Wireless Sensor Networks (WSNs) play an important role in increasing the ubiquity of networks with smart devices that are low-cost and easy to deploy. However, sensor nodes are restricted in terms of energy, processing and memory. Additionally, low-power radios are very sensitive to noise, interference and multipath distortions. In this context, this article proposes a routing protocol based on Routing by Energy and Link quality (REL) for IoT applications. To increase reliability and energy-efficiency, REL selects routes on the basis of a proposed end-to-end link quality estimator mechanism, residual energy and hop count. Furthermore, REL proposes an event-driven mechanism to provide load balancing and avoid the premature energy depletion of nodes/networks. Performance evaluations were carried out using simulation and testbed experiments to show the impact and benefits of REL in small and large-scale networks. The results show that REL increases the network lifetime and services availability, as well as the quality of service of IoT applications. It also provides an even distribution of scarce network resources and reduces the packet loss rate, compared with the performance of well-known protocols. PMID:23385410
Chaimani, Anna; Caldwell, Deborah M; Li, Tianjing; Higgins, Julian P T; Salanti, Georgia
2017-03-01
The number of systematic reviews that aim to compare multiple interventions using network meta-analysis is increasing. In this study, we highlight aspects of a standard systematic review protocol that may need modification when multiple interventions are to be compared. We take the protocol format suggested by Cochrane for a standard systematic review as our reference and compare the considerations for a pairwise review with those required for a valid comparison of multiple interventions. We suggest new sections for protocols of systematic reviews including network meta-analyses with a focus on how to evaluate their assumptions. We provide example text from published protocols to exemplify the considerations. Standard systematic review protocols for pairwise meta-analyses need extensions to accommodate the increased complexity of network meta-analysis. Our suggested modifications are widely applicable to both Cochrane and non-Cochrane systematic reviews involving network meta-analyses. Copyright © 2017 Elsevier Inc. All rights reserved.
ZERO: probabilistic routing for deploy and forget Wireless Sensor Networks.
Vilajosana, Xavier; Llosa, Jordi; Pacho, Jose Carlos; Vilajosana, Ignasi; Juan, Angel A; Vicario, Jose Lopez; Morell, Antoni
2010-01-01
As Wireless Sensor Networks are being adopted by industry and agriculture for large-scale and unattended deployments, the need for reliable and energy-conservative protocols become critical. Physical and Link layer efforts for energy conservation are not mostly considered by routing protocols that put their efforts on maintaining reliability and throughput. Gradient-based routing protocols route data through most reliable links aiming to ensure 99% packet delivery. However, they suffer from the so-called "hot spot" problem. Most reliable routes waste their energy fast, thus partitioning the network and reducing the area monitored. To cope with this "hot spot" problem we propose ZERO a combined approach at Network and Link layers to increase network lifespan while conserving reliability levels by means of probabilistic load balancing techniques.
Relative binding affinity prediction of farnesoid X receptor in the D3R Grand Challenge 2 using FEP.
Schindler, Christina; Rippmann, Friedrich; Kuhn, Daniel
2018-01-01
Physics-based free energy simulations have increasingly become an important tool for predicting binding affinity and the recent introduction of automated protocols has also paved the way towards a more widespread use in the pharmaceutical industry. The D3R 2016 Grand Challenge 2 provided an opportunity to blindly test the commercial free energy calculation protocol FEP+ and assess its performance relative to other affinity prediction methods. The present D3R free energy prediction challenge was built around two experimental data sets involving inhibitors of farnesoid X receptor (FXR) which is a promising anticancer drug target. The FXR binding site is predominantly hydrophobic with few conserved interaction motifs and strong induced fit effects making it a challenging target for molecular modeling and drug design. For both data sets, we achieved reasonable prediction accuracy (RMSD ≈ 1.4 kcal/mol, rank 3-4 according to RMSD out of 20 submissions) comparable to that of state-of-the-art methods in the field. Our D3R results boosted our confidence in the method and strengthen our desire to expand its applications in future in-house drug design projects.
Relative binding affinity prediction of farnesoid X receptor in the D3R Grand Challenge 2 using FEP+
NASA Astrophysics Data System (ADS)
Schindler, Christina; Rippmann, Friedrich; Kuhn, Daniel
2018-01-01
Physics-based free energy simulations have increasingly become an important tool for predicting binding affinity and the recent introduction of automated protocols has also paved the way towards a more widespread use in the pharmaceutical industry. The D3R 2016 Grand Challenge 2 provided an opportunity to blindly test the commercial free energy calculation protocol FEP+ and assess its performance relative to other affinity prediction methods. The present D3R free energy prediction challenge was built around two experimental data sets involving inhibitors of farnesoid X receptor (FXR) which is a promising anticancer drug target. The FXR binding site is predominantly hydrophobic with few conserved interaction motifs and strong induced fit effects making it a challenging target for molecular modeling and drug design. For both data sets, we achieved reasonable prediction accuracy (RMSD ≈ 1.4 kcal/mol, rank 3-4 according to RMSD out of 20 submissions) comparable to that of state-of-the-art methods in the field. Our D3R results boosted our confidence in the method and strengthen our desire to expand its applications in future in-house drug design projects.
Comparison of protocols measuring diffusion and partition coefficients in the stratum corneum
Rothe, H.; Obringer, C.; Manwaring, J.; Avci, C.; Wargniez, W.; Eilstein, J.; Hewitt, N.; Cubberley, R.; Duplan, H.; Lange, D.; Jacques‐Jamin, C.; Klaric, M.; Schepky, A.
2017-01-01
Abstract Partition (K) and diffusion (D) coefficients are important to measure for the modelling of skin penetration of chemicals through the stratum corneum (SC). We compared the feasibility of three protocols for the testing of 50 chemicals in our main studies, using three cosmetics‐relevant model chemicals with a wide range of logP values. Protocol 1: SC concentration‐depth profile using tape‐stripping (measures KSC/v and DSC/HSC 2, where HSC is the SC thickness); Protocol 2A: incubation of isolated SC with chemical (direct measurement of KSC/v only) and Protocol 2B: diffusion through isolated SC mounted on a Franz cell (measures KSC/v and DSC/HSC 2, and is based on Fick's laws). KSC/v values for caffeine and resorcinol using Protocol 1 and 2B were within 30% of each other, values using Protocol 2A were ~two‐fold higher, and all values were within 10‐fold of each other. Only indirect determination of KSC/v by Protocol 2B was different from the direct measurement of KSC/v by Protocol 2A and Protocol 1 for 7‐EC. The variability of KSC/v for all three chemicals using Protocol 2B was higher compared to Protocol 1 and 2A. DSC/HSC 2 values for the three chemicals were of the same order of magnitude using all three protocols. Additionally, using Protocol 1, there was very little difference between parameters measured in pig and human SC. In conclusion, KSC/v, and DSC values were comparable using different methods. Pig skin might be a good surrogate for human skin for the three chemicals tested. Copyright © 2017 The Authors Journal of Applied Toxicology published by John Wiley & Sons Ltd. PMID:28139006
Lundgaard, E; Wouda, M F; Strøm, V
2017-10-01
This is a comparative study of two exercise testing protocols. The objective of this study was to compare maximal oxygen uptake (VO 2 max) and achieved criteria for maximal exercise testing between the Sunnaas Protocol-a newly designed treadmill exercise test protocol-and the Modified Bruce Protocol in persons with incomplete spinal cord injury (SCI). This study was conducted in Sunnaas Rehabilitation Hospital, Norway. Twenty persons (19 men) with incomplete SCI (AIS D) capable of ambulating without assistive devices performed two treadmill walking exercise tests (Sunnaas Protocol and Modified Bruce Protocol) until exhaustion 1-3 days apart. The key differences between the protocols are the smaller increments in speed and shorter duration on each workload in the Sunnaas Protocol. Cardiovascular responses were measured continuously throughout both tests. The subjects exhibited statistically significantly higher VO 2 max when using the Sunnaas Protocol (37.1±9.9 vs 35.4±9.8 ml kg -1 min -1 , P=0.01), with a mean between-test difference of 1.8 ml kg -1 min -1 (95% confidence interval: 0.49-3.16). There was no significant difference in mean maximal heart rate (HR max). Nineteen (95%) subjects achieved at least three of the four criteria for maximal oxygen uptake using the Sunnaas Protocol. Thirteen (65%) subjects achieved at least three of the criteria using a Modified Bruce protocol. The small differences in both VO 2 max and achieved criteria in favor of the Sunnaas Protocol suggest that it could be a useful alternative treadmill exercise test protocol for ambulating persons with incomplete SCI.
21st Century Water Asset Accounting: Implications Report (WERF Report INFR6R12b)
This project is an important first step towards developing water industry standards and accounting protocols for green infrastructure that could be adopted by the Governmental Accounting Standards Board (GASB) to promote green infrastructure investment. Green infrastructure, the ...
15 CFR 783.2 - Amended reports.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Amended reports. 783.2 Section 783.2 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS CIVIL NUCLEAR FUEL CYCLE...
Increased conception rates in beef cattle inseminated with nanopurified bull semen
USDA-ARS?s Scientific Manuscript database
Reproductive performance is of paramount importance to the cattle industry. Since recent progress has been achieved by optimizing estrus and ovulation synchronization protocols in cows, improvements are desired to increase the fertility of bulls enrolled in artificial insemination (AI) programs. Thi...
Code of Federal Regulations, 2010 CFR
2010-01-01
... INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.9 Subpoenas..., records or other documentary or physical evidence for the purpose of the hearing, as the ALJ deems... least 10 business days before the scheduled hearing or deposition, unless the ALJ determines, for good...
47 CFR 7.9 - Information pass through.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-manufacturer, non-proprietary, industry-standard codes, translation protocols, formats or other information..., signal compression technologies shall not remove information needed for access or shall restore it upon... 47 Telecommunication 1 2010-10-01 2010-10-01 false Information pass through. 7.9 Section 7.9...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-29
... regarding how and when data collection forms and standard operating procedures should be included with the... topic. It does not create or confer any rights for or on any person and does not operate to bind FDA or...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Discovery. 785.8 Section 785.8... INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.8 Discovery. (a) General. The parties are encouraged to engage in voluntary discovery regarding any matter, not...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 15 Commerce and Foreign Trade 2 2012-01-01 2012-01-01 false Discovery. 785.8 Section 785.8... INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.8 Discovery. (a) General. The parties are encouraged to engage in voluntary discovery regarding any matter, not...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 15 Commerce and Foreign Trade 2 2013-01-01 2013-01-01 false Discovery. 785.8 Section 785.8... INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.8 Discovery. (a) General. The parties are encouraged to engage in voluntary discovery regarding any matter, not...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 15 Commerce and Foreign Trade 2 2014-01-01 2014-01-01 false Discovery. 785.8 Section 785.8... INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.8 Discovery. (a) General. The parties are encouraged to engage in voluntary discovery regarding any matter, not...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Discovery. 785.8 Section 785.8... INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.8 Discovery. (a) General. The parties are encouraged to engage in voluntary discovery regarding any matter, not...
15 CFR 784.3 - Scope and conduct of complementary access.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., safety, and security regulations (e.g., regulations for protection of controlled environments within the... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS... presence of a U.S. Government Host Team. No information of direct national security significance shall be...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barratt, B.I.P.; Moeed, A.; Malone, L.A.
2006-05-15
An analysis of established biosafety protocols for release into the environment of exotic plants and biological control agents for weeds and arthropod pests has been carried out to determine whether such protocols can be applied to relatively new and emerging technologies intended for the primary production industries, such as transgenic plants. Example case studies are described to indicate the scope of issues considered by regulators who make decisions on new organism releases. No transgenic plants have been released to date in New Zealand, but two field test approvals are described as examples. An analysis of the biosafety protocols has shownmore » that, while many of the risk criteria considered for decision-making by regulators are similar for all new organisms, a case-by-case examination of risks and potential impacts is required in order to fully assess risk. The value of post-release monitoring and validation of decisions made by regulators is emphasised.« less
NASA Astrophysics Data System (ADS)
Reddy, K. Rasool; Rao, Ch. Madhava
2018-04-01
Currently safety is one of the primary concerns in the transmission of images due to increasing the use of images within the industrial applications. So it's necessary to secure the image facts from unauthorized individuals. There are various strategies are investigated to secure the facts. In that encryption is certainly one of maximum distinguished method. This paper gives a sophisticated Rijndael (AES) algorithm to shield the facts from unauthorized humans. Here Exponential Key Change (EKE) concept is also introduced to exchange the key between client and server. The things are exchange in a network among client and server through a simple protocol is known as Trivial File Transfer Protocol (TFTP). This protocol is used mainly in embedded servers to transfer the data and also provide protection to the data if protection capabilities are integrated. In this paper, implementing a GUI environment for image encryption and decryption. All these experiments carried out on Linux environment the usage of Open CV-Python script.
Couderc, Carine; Nappez, Claude; Drancourt, Michel
2012-03-30
It is recommended that harmful Biosafety Level 3 (BSL-3) bacteria be inactivated prior to identification by mass spectrometry, yet optimal effects of inactivation protocol have not been defined. Here, we compare trifluoroacetic acid inactivation (protocol A) with ethanol inactivation (protocol B) of Yersinia organisms prior to identification by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The total number of peaks detected was 10.5 ± 1.7 for protocol A and 15.7 ± 4.2 for protocol B (ρ <0.001, ANOVA test). The signal-to-noise ratio for the m/z 6049 peak present in all of the tested Yersinia isolates was 9.7 ± 3.1 for protocol A and 18.1 ± 4.6 for protocol B (ρ < 0.001). Compared with spectra in our local database containing 48 Yersinia spp., including 20 strains of Y. pestis, the identification score was 1.79 ± 0.2 for protocol A and 1.97 ± 0.19 for protocol B (ρ = 0.0024). Our observations indicate that for the identification of Yersinia organisms, ethanol inactivation yielded MALDI-TOF-MS spectra of significantly higher quality than spectra derived from trifluoroacetic acid inactivation. Combined with previously published data, our results permit the updating of protocols for inactivating BSL-3 bacteria. Copyright © 2012 John Wiley & Sons, Ltd.
DeAtley, Heather N; Burton, Amanda; Fraley, Michelle DeLuca; Haltom, Joan
2017-07-01
The authors sought to evaluate the impact on length of hospital stay and treatment duration of morphine after implementation of a change in the institutional protocol for managing neonatal abstinence syndrome (NAS) in an effort to improve patient outcomes. A single-center, retrospective chart review was conducted at a Level II nursery in a community hospital in Kentucky. Fifty-nine neonates born between January 1, 2014, and December 31, 2015, who were diagnosed with NAS and received morphine for treatment were included. The protocol 1 group consisted of 33 neonates who received an initial dose of morphine 0.04 mg/kg/dose administered orally every 4 hours (January 1-December 31, 2014), and the protocol 2 group consisted of 26 neonates who received an initial dose of morphine 0.06 mg/kg/dose administered orally every 3 hours (January 1-November 30, 2015), after a change in the protocol for managing NAS was implemented on January 1, 2015. Data were reviewed and compared between the two protocol groups to determine the impact that the dosage change had on length of hospital stay and morphine treatment duration. The average length of stay decreased by 7 days in the protocol 2 group compared with the protocol 1 group (21 vs 28.65 days). The average duration of treatment decreased by 7 days in the protocol 2 group compared with the protocol 1 group (18.3 vs 25.4 days). These differences between groups were not statistically significant, however, because the population size was not large enough to achieve adequate power. These results indicate that protocol 2 displayed the potential to decrease length of stay and duration of treatment compared with protocol 1 at this facility; however, balancing higher starting doses with the risk of oversedation will continue to challenge the health care team. Concern for oversedation when using the higher starting dose in protocol 2 has prompted further research (e.g., protocol 3, initial morphine 0.05 mg/kg/dose every 3 hrs). Continued research is also necessary with larger patient populations to enable generalizability to other institutions. © 2017 Pharmacotherapy Publications, Inc.
Interfacing the Controllogics PLC over Ethernet/IP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasemir, K. U.; Dalesio, L. R.
2001-01-01
The Allen-Bradley ControlLogix [1] line of programmable logic controllers (PLCs) offers several interfaces: Ethernet, ControlNet, DeviceNet, RS-232 and others. The ControlLogix Ethernet interface module 1756-ENET uses EtherNet/IP, the ControlNet protocol [2], encapsulated in Ethernet packages, with specific service codes [3]. A driver for the Experimental Physics and Industrial Control System (EPICS) has been developed that utilizes this EtherNet/IP protocol for controllers running the vxWorks RTOS as well as a Win32 and Unix/Linux test program. Features, performance and limitations of this interface are presented.
Beef alliances: motivations, extent, and future prospects.
Schroeder, Ted C; Kovanda, Joseph
2003-07-01
With their growth, it is important to consider how alliances will impact the beef industry in the future. Alliances have the potential to make sweeping changes to cattle production, live and feeder cattle marketing, food safety protocols, use of government grades and standards, ownership structure, supply chain management, wholesale and retail product marketing, risk management, and many other industry activities. In an effort to address these issues, this article addresses the following questions: What is an alliance? What has motivated their proliferation? What have we learned from alliances? What aspects of alliances affect their likelihood of success or failure? What is the future of alliances? Are they a fad or a long-term evolving industry structural change?
Knowledge elicitation techniques and application to nuclear plant maintenance
NASA Astrophysics Data System (ADS)
Doyle, E. Kevin
The new millennium has brought with it the opportunity of global trade which in turn requires the utmost in efficiency from each individual industry. This includes the nuclear power industry, a point which was emphasized when the electrical generation industry began to be de regulated across North America the late 1990s and re-emphasized when the northeast power grid of North America collapsed in the summer of 2003. This dissertation deals with reducing the cost of the maintenance function of Candu nuclear power plants and initiating a strong link between universities and the Canadian nuclear industry. Various forms of RCM (reliability-centred maintenance) have been the tools of choice in industry for improving the maintenance function during the last 20 years. In this project, pilot studies, conducted at Bruce Power between 1999 and 2005, and reported on in this dissertation, lay out a path to implement statistical improvements as the next step after RCM in reducing the cost of the maintenance. Elicitation protocols, designed for the age group being elicited, address the much-documented issue of a lack of data. Clear, graphical, inferential statistical interfaces are accentuated and developed to aid in building the teams required to implement the various methodologies and to help in achieving funding targets. Graphical analysis and Crow/AMSAA (army materials systems analysis activity) plots are developed and demonstrated from the point of view of justifying the expenditures of cost reduction efforts. This dissertation ultimately speaks to the great opportunity being presented by this approach at this time: of capturing the baby-boom generation's huge pool of knowledge before those people retire. It is expected that the protocols and procedures referenced here will have applicability across the many disciplines where collecting expert information from a similar age group is required.
Pisciolaro, Ricardo Luiz; Duailibi, Monica Talarico; Novo, Neil Ferreira; Juliano, Yara; Pallos, Debora; Yelick, Pamela Crotty; Vacanti, Joseph Phillip; Ferreira, Lydia Masako; Duailibi, Silvio Eduardo
2015-11-01
One of the goals in using cells for tissue engineering (TE) and cell therapy consists of optimizing the medium for cell culture. The present study compares three different blood product supplements for improved cell proliferation and protection against DNA damage in cultured human dental pulp stem cells for tooth TE applications. Human cells from dental pulp were first characterized as adult stem cells (ectomesenchymal mixed origin) by flow cytometry. Next, four different cell culture conditions were tested: I, supplement-free; II, supplemented with fetal bovine serum; III, allogeneic human serum; and IV, autologous human serum. Cultured cells were then characterized for cell proliferation, mineralized nodule formation, and colony-forming units (CFU) capability. After 28 days in culture, the comet assay was performed to assess possible damage in cellular DNA. Our results revealed that Protocol IV achieved higher cell proliferation than Protocol I (p = 0.0112). Protocols II and III resulted in higher cell proliferation than Protocol I, but no statistical differences were found relative to Protocol IV. The comet assay revealed less cell damage in cells cultured using Protocol IV as compared to Protocols II and III. The damage percentage observed on Protocol II was significantly higher than all other protocols. CFUs capability was highest using Protocol IV (p = 0.0018) and III, respectively, and the highest degree of mineralization was observed using Protocol IV as compared to Protocols II and III. Protocol IV resulted in significantly improved cell proliferation, and no cell damage was observed. These results demonstrate that human blood product supplements can be used as feasible supplements for culturing adult human dental stem cells.
NASA Astrophysics Data System (ADS)
Raju, Kota Solomon; Merugu, Naresh Babu; Neetu, Babu, E. Ram
2016-03-01
ZigBee is well-accepted industrial standard for wireless sensor networks based on IEEE 802.15.4 standard. Wireless Sensor Networks is the major concern of communication these days. These Wireless Sensor Networks investigate the properties of networks of small battery-powered sensors with wireless communication. The communication between any two wireless nodes of wireless sensor networks is carried out through a protocol stack. This protocol stack has been designed by different vendors in various ways. Every custom vendor possesses his own protocol stack and algorithms especially at the MAC layer. But, many applications require modifications in their algorithms at various layers as per their requirements, especially energy efficient protocols at MAC layer that are simulated in Wireless sensor Network Simulators which are not being tested in real time systems because vendors do not allow the programmability of each layer in their protocol stack. This problem can be quoted as Vendor-Interoperability. The solution is to develop the programmable protocol stack where we can design our own application as required. As a part of the task first we tried implementing physical layer and transmission of data using physical layer. This paper describes about the transmission of the total number of bytes of Frame according to the IEEE 802.15.4 standard using Physical Layer.
Security analysis of standards-driven communication protocols for healthcare scenarios.
Masi, Massimiliano; Pugliese, Rosario; Tiezzi, Francesco
2012-12-01
The importance of the Electronic Health Record (EHR), that stores all healthcare-related data belonging to a patient, has been recognised in recent years by governments, institutions and industry. Initiatives like the Integrating the Healthcare Enterprise (IHE) have been developed for the definition of standard methodologies for secure and interoperable EHR exchanges among clinics and hospitals. Using the requisites specified by these initiatives, many large scale projects have been set up for enabling healthcare professionals to handle patients' EHRs. The success of applications developed in these contexts crucially depends on ensuring such security properties as confidentiality, authentication, and authorization. In this paper, we first propose a communication protocol, based on the IHE specifications, for authenticating healthcare professionals and assuring patients' safety. By means of a formal analysis carried out by using the specification language COWS and the model checker CMC, we reveal a security flaw in the protocol thus demonstrating that to simply adopt the international standards does not guarantee the absence of such type of flaws. We then propose how to emend the IHE specifications and modify the protocol accordingly. Finally, we show how to tailor our protocol for application to more critical scenarios with no assumptions on the communication channels. To demonstrate feasibility and effectiveness of our protocols we have fully implemented them.
Developing a guideline for clinical trial protocol content: Delphi consensus survey
2012-01-01
Background Recent evidence has highlighted deficiencies in clinical trial protocols, having implications for many groups. Existing guidelines for randomized clinical trial (RCT) protocol content vary substantially and most do not describe systematic methodology for their development. As one of three prespecified steps for the systematic development of a guideline for trial protocol content, the objective of this study was to conduct a three-round Delphi consensus survey to develop and refine minimum content for RCT protocols. Methods Panellists were identified using a multistep iterative approach, met prespecified minimum criteria and represented key stakeholders who develop or use clinical trial protocols. They were asked to rate concepts for importance in a minimum set of items for RCT protocols. The main outcome measures were degree of importance (scale of 1 to 10; higher scores indicating higher importance) and level of consensus for items. Results were presented as medians, interquartile ranges, counts and percentages. Results Ninety-six expert panellists participated in the Delphi consensus survey including trial investigators, methodologists, research ethics board members, funders, industry, regulators and journal editors. Response rates were between 88 and 93% per round. Overall, panellists rated 63 of 88 concepts of high importance (of which 50 had a 25th percentile rating of 8 or greater), 13 of moderate importance (median 6 or 7) and 12 of low importance (median less than or equal to 5) for minimum trial protocol content. General and item-specific comments and subgroup results provided valuable insight for further discussions. Conclusions This Delphi process achieved consensus from a large panel of experts from diverse stakeholder groups on essential content for RCT protocols. It also highlights areas of divergence. These results, complemented by other empirical research and consensus meetings, are helping guide the development of a guideline for protocol content. PMID:23006145
NASA Technical Reports Server (NTRS)
Reinhart, Richard C.
1993-01-01
The Communication Protocol Software was developed at the NASA Lewis Research Center to support the Advanced Communications Technology Satellite High Burst Rate Link Evaluation Terminal (ACTS HBR-LET). The HBR-LET is an experimenters terminal to communicate with the ACTS for various experiments by government, university, and industry agencies. The Communication Protocol Software is one segment of the Control and Performance Monitor (C&PM) Software system of the HBR-LET. The Communication Protocol Software allows users to control and configure the Intermediate Frequency Switch Matrix (IFSM) on board the ACTS to yield a desired path through the spacecraft payload. Besides IFSM control, the C&PM Software System is also responsible for instrument control during HBR-LET experiments, uplink power control of the HBR-LET to demonstrate power augmentation during signal fade events, and data display. The Communication Protocol Software User's Guide, Version 1.0 (NASA CR-189162) outlines the commands and procedures to install and operate the Communication Protocol Software. Configuration files used to control the IFSM, operator commands, and error recovery procedures are discussed. The Communication Protocol Software Maintenance Manual, Version 1.0 (NASA CR-189163, to be published) is a programmer's guide to the Communication Protocol Software. This manual details the current implementation of the software from a technical perspective. Included is an overview of the Communication Protocol Software, computer algorithms, format representations, and computer hardware configuration. The Communication Protocol Software Test Plan (NASA CR-189164, to be published) provides a step-by-step procedure to verify the operation of the software. Included in the Test Plan is command transmission, telemetry reception, error detection, and error recovery procedures.
Jonker, Dirk; Gustafsson, Ewa; Rolander, Bo; Arvidsson, Inger; Nordander, Catarina
2015-01-01
A new health surveillance protocol for work-related upper-extremity musculoskeletal disorders has been validated by comparing the results with a reference protocol. The studied protocol, Health Surveillance in Adverse Ergonomics Conditions (HECO), is a new version of the reference protocol modified for application in the Occupational Health Service (OHS). The HECO protocol contains both a screening part and a diagnosing part. Sixty-three employees were examined. The screening in HECO did not miss any diagnosis found when using the reference protocol, but in comparison to the reference protocol considerable time savings could be achieved. Fair to good agreement between the protocols was obtained for one or more diagnoses in neck/shoulders (86%, k = 0.62) and elbow/hands (84%, k = 0.49). Therefore, the results obtained using the HECO protocol can be compared with a reference material collected with the reference protocol, and thus provide information of the magnitude of disorders in an examined work group. Practitioner Summary: The HECO protocol is a relatively simple physical examination protocol for identification of musculoskeletal disorders in the neck and upper extremities. The protocol is a reliable and cost-effective tool for the OHS to use for occupational health surveillance in order to detect workplaces at high risk for developing musculoskeletal disorders.
Industrial-scale radio frequency treatments for insect control in lentils
USDA-ARS?s Scientific Manuscript database
Radio frequency (RF) treatments are considered to be a potential postharvest technology for disinfesting legumes of internal seed pests such as the cowpea weevil. After treatment protocols are shown to control postharvest insects without significant quality degradation, it is important to scale-up l...
USDA-ARS?s Scientific Manuscript database
Radio frequency (RF) treatments have potential as alternatives to chemical fumigation for phytosanitary disinfestation treatments in the dried nut industry. To develop effective RF treatment protocols for almonds, it is desirable to determine heating uniformity and the occurrence of differential hea...
Boll sampling protocols and their impact on measurements of cotton fiber quality
USDA-ARS?s Scientific Manuscript database
Within plant fiber variability has long contributed to product inconsistency in the cotton industry. Fiber quality uniformity is a primary plant breeding objective related to cotton commodity economic value. The physiological impact of source and sink relationships renders stress on the upper bran...
Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang
2017-01-01
To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80 each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. • Automatic spectral imaging protocol selection provides appropriate scan protocols. • Abdominal CT is feasible using spectral imaging and 300 mgI/kg contrast agent. • 50-keV monochromatic images with 50 % ASIR provide optimal image quality.
Evaluation of an adult insulin infusion protocol at an academic medical center.
Petrov, Katerina I; Burns, Tammy L; Drincic, Andjela
2012-05-01
Acknowledging evidence of possible detrimental effects of tightly controlled blood glucose levels, the American Association of Clinical Endocrinologists and the American Diabetes Association published a consensus statement recommending less strict control for most diabetic patients. As a result of these recommendations, our academic center at Creighton University Medical Center revised its adult insulin infusion protocol to target blood glucose levels ranging from 120 to 180 mg/dL for regular (standard) glycemic control and 80 to 120 mg/dL for tight control; previous targets had ranged from 80 to 180 mg/dL and 70 to 110 mg/dL, respectively. The primary objective was to evaluate the time that blood glucose values were within the target range for patients receiving the new protocol, compared with patients receiving the previous protocol. Our study was designed to evaluate the effectiveness and safety of the revised protocol. Using a retrospective chart review, we collected data for 4 months from patients on the old insulin protocol (May to August 2009) and for 4 months from patients on the new protocol (September to December 2009). Secondary endpoints included the number of hypoglycemic episodes (blood glucose below 70 mg/dL) and severe hypoglycemic episodes (blood glucose 40 mg/dL or lower) experienced by patients receiving the new insulin protocol compared with those receiving the former protocol. Patient characteristics were similar at baseline. Blood glucose values stayed within the target range for a significantly shorter time with the new protocol than with the former protocol (44.6% vs. 56.8%, respectively; P < 0.001), probably because of the narrower target range in the revised protocol. No statistically significant differences in hypoglycemia were observed after the protocol was changed. Hypoglycemia occurred in 31% of the former-protocol patients compared with 18% of the revised-protocol patients. Severe hypoglycemia was experienced by 2.1% of patients on the old protocol and by 3.1% of patients on the new protocol. Rates of severe hypoglycemia were low (2.6%) with the original protocol. Patients' blood glucose levels were within the target range for a shorter time with the new protocol. Fewer episodes of hypoglycemia were recorded with the new protocol, but rates of severe hypoglycemia were similar with both protocols.
Secure multiparty computation of a comparison problem.
Liu, Xin; Li, Shundong; Liu, Jian; Chen, Xiubo; Xu, Gang
2016-01-01
Private comparison is fundamental to secure multiparty computation. In this study, we propose novel protocols to privately determine [Formula: see text], or [Formula: see text] in one execution. First, a 0-1-vector encoding method is introduced to encode a number into a vector, and the Goldwasser-Micali encryption scheme is used to compare integers privately. Then, we propose a protocol by using a geometric method to compare rational numbers privately, and the protocol is information-theoretical secure. Using the simulation paradigm, we prove the privacy-preserving property of our protocols in the semi-honest model. The complexity analysis shows that our protocols are more efficient than previous solutions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Molina, R.; O'Dell, T.; Luoma, D.
1993-02-01
The commercial harvest of edible, forest fungi has a multimillion dollar industry with several thousand tons harvested annually. The primary objectives of the overview paper are to provide information on the biology of forest fungi, describe the major edible fungi harvested in the Pacific Northwest, integrate a perspective on the social aspects of the mushroom harvest issue, summarize the development of the commercial mushroom industry, and suggest research and monitoring protocols for developing management guidelines.
Comparative Study on Various Authentication Protocols in Wireless Sensor Networks.
Rajeswari, S Raja; Seenivasagam, V
2016-01-01
Wireless sensor networks (WSNs) consist of lightweight devices with low cost, low power, and short-ranged wireless communication. The sensors can communicate with each other to form a network. In WSNs, broadcast transmission is widely used along with the maximum usage of wireless networks and their applications. Hence, it has become crucial to authenticate broadcast messages. Key management is also an active research topic in WSNs. Several key management schemes have been introduced, and their benefits are not recognized in a specific WSN application. Security services are vital for ensuring the integrity, authenticity, and confidentiality of the critical information. Therefore, the authentication mechanisms are required to support these security services and to be resilient to distinct attacks. Various authentication protocols such as key management protocols, lightweight authentication protocols, and broadcast authentication protocols are compared and analyzed for all secure transmission applications. The major goal of this survey is to compare and find out the appropriate protocol for further research. Moreover, the comparisons between various authentication techniques are also illustrated.
Comparative Study on Various Authentication Protocols in Wireless Sensor Networks
Rajeswari, S. Raja; Seenivasagam, V.
2016-01-01
Wireless sensor networks (WSNs) consist of lightweight devices with low cost, low power, and short-ranged wireless communication. The sensors can communicate with each other to form a network. In WSNs, broadcast transmission is widely used along with the maximum usage of wireless networks and their applications. Hence, it has become crucial to authenticate broadcast messages. Key management is also an active research topic in WSNs. Several key management schemes have been introduced, and their benefits are not recognized in a specific WSN application. Security services are vital for ensuring the integrity, authenticity, and confidentiality of the critical information. Therefore, the authentication mechanisms are required to support these security services and to be resilient to distinct attacks. Various authentication protocols such as key management protocols, lightweight authentication protocols, and broadcast authentication protocols are compared and analyzed for all secure transmission applications. The major goal of this survey is to compare and find out the appropriate protocol for further research. Moreover, the comparisons between various authentication techniques are also illustrated. PMID:26881272
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Michael; Haeri, Hossein; Reynolds, Arlis
This chapter provides a set of model protocols for determining energy and demand savings that result from specific energy efficiency measures implemented through state and utility efficiency programs. The methods described here are approaches that are or are among the most commonly used and accepted in the energy efficiency industry for certain measures or programs. As such, they draw from the existing body of research and best practices for energy efficiency program evaluation, measurement, and verification (EM&V). These protocols were developed as part of the Uniform Methods Project (UMP), funded by the U.S. Department of Energy (DOE). The principal objectivemore » for the project was to establish easy-to-follow protocols based on commonly accepted methods for a core set of widely deployed energy efficiency measures.« less
New Protocol for Skin Landmark Registration in Image-Guided Neurosurgery: Technical Note.
Gerard, Ian J; Hall, Jeffery A; Mok, Kelvin; Collins, D Louis
2015-09-01
Newer versions of the commercial Medtronic StealthStation allow the use of only 8 landmark pairs for patient-to-image registration as opposed to 9 landmarks in older systems. The choice of which landmark pair to drop in these newer systems can have an effect on the quality of the patient-to-image registration. To investigate 4 landmark registration protocols based on 8 landmark pairs and compare the resulting registration accuracy with a 9-landmark protocol. Four different protocols were tested on both phantoms and patients. Two of the protocols involved using 4 ear landmarks and 4 facial landmarks and the other 2 involved using 3 ear landmarks and 5 facial landmarks. Both the fiducial registration error and target registration error were evaluated for each of the different protocols to determine any difference between them and the 9-landmark protocol. No difference in fiducial registration error was found between any of the 8-landmark protocols and the 9-landmark protocol. A significant decrease (P < .05) in target registration error was found when using a protocol based on 4 ear landmarks and 4 facial landmarks compared with the other protocols based on 3 ear landmarks. When using 8 landmarks to perform the patient-to-image registration, the protocol using 4 ear landmarks and 4 facial landmarks greatly outperformed the other 8-landmark protocols and 9-landmark protocol, resulting in the lowest target registration error.
Desjeux, J F; Briend, A; Prudhon, C; Greletty, Y; Golden, M H
1998-01-01
Nowadays, median case fatality rate of severely malnourished children treated in hospitals is 23.5%, a rate which has not changed for the last 50 years. This is probably related to the use of inappropriate or even unsafe treatment protocols. This work aimed at reducing case fatality rates of severe malnutrition by developing a treatment protocol and assessing its effectiveness during humanitarian crises. A therapeutic food was designed from pathophysiologic studies and its use adapted to therapeutic feeding centres. This food (F100) contains 100 Kcal/100 ml, with 10% of its energy derived from proteins; it has a low sodium and iron content but is fortified with vitamins and minerals. It can be prepared either at the treatment centre or at an industrial level. Industrial production, which started in 1993 reached 1,500 MT in 1997. In refugee camps, F100 was used according to a strict protocol adapted to local conditions. Intakes started at 100 Kcal/kg/day and reached 200 kcal/kg/day once appetite was restored. A model to assess the risk of death according to weight, height and oedema was developed. First results show that mortality was often below 5%. Hence, it is possible to standardise and evaluate a nutritional treatment in such unfavourable conditions as a refugee camp. Standardised use of F100 can markedly reduce mortality of severely malnourished children.
The importance of carbon footprint estimation boundaries.
Matthews, H Scott; Hendrickson, Chris T; Weber, Christopher L
2008-08-15
Because of increasing concern about global climate change and carbon emissions as a causal factor, many companies and organizations are pursuing "carbon footprint" projects to estimate their own contributions to global climate change. Protocol definitions from carbon registries help organizations analyze their footprints. The scope of these protocols varies but generally suggests estimating only direct emissions and emissions from purchased energy, with less focus on supply chain emissions. In contrast approaches based on comprehensive environmental life-cycle assessment methods are available to track total emissions across the entire supply chain, and experience suggests that following narrowly defined estimation protocols will generally lead to large underestimates of carbon emissions for providing products and services. Direct emissions from an industry are, on average, only 14% of the total supply chain carbon emissions (often called Tier 1 emissions), and direct emissions plus industry energy inputs are, on average, only 26% of the total supply chain emissions (often called Tier 1 and 2 emissions). Without a full knowledge of their footprints, firms will be unable to pursue the most cost-effective carbon mitigation strategies. We suggest that firms use the screening-level analysis described here to set the bounds of their footprinting strategy to ensure that they do not ignore large sources of environmental effects across their supply chains. Such information can help firms pursue carbon and environmental emission mitigation projects not only within their own plants but also across their supply chain.
Comparison of Physiological and Perceptual Responses Between Continuous and Intermittent Cycling
Brasil, Roxana M.; Barreto, Ana C.; Nogueira, Leandro; Santos, Edil; Novaes, Jefferson S.; Reis, Victor M.
2011-01-01
The present study tested the hypothesis that the exercise protocol (continuous vs. intermittent) would affect the physiological response and the perception of effort during aquatic cycling. Each protocol was divided on four stages. Heart rate, arterial blood pressure, blood lactate concentration, central and peripheral rate of perceived exertion were collected in both protocols in aquatic cycling in 10 women (values are mean ± SD): age=32.8 ± 4.8 years; height=1.62 ± 0.05 cm; body mass=61.60 ± 5.19 kg; estimated body fat=27.13 ± 4.92%. Protocols were compared through two way ANOVA with Scheffé’s post-hoc test and the test of Mann- Whitney for rate of perceived exertion with α=0.05. No systematic and consistent differences in heart rate, arterial blood pressure, double product and blood lactate concentration were found between protocols. On the other hand, central rate of perceived exertion was significantly higher at stage four during continuous protocol compared with intermittent protocol (p=0.01), while the peripheral rate of perceived exertion presented higher values at stages three (p=0.02) and four (p=0.00) in the continuous protocol when compared to the results found in intermittent protocol. These findings suggest that although the aquatic cycling induces similar physiologic demands in both protocols, the rate of perceived exertion may vary according to the continuous vs. intermittent nature of the exercise. PMID:23487483
Santas, Jonathan; Lázaro, Elisabet; Cuñé, Jordi
2017-09-01
In the present study we evaluated the weight loss effect of a polysaccharide-rich food supplement, LipiGo®, comprising a specific β-glucan-chitin-chitosan fraction (BGCC) obtained from the chemical hydrolysis of Saccharomyces cerevisiae, resulting as a by-product of the brewing process. A randomised, double-blind, placebo-controlled clinical trial was performed enrolling 56 overweight and obese subjects (body mass index, BMI, 25-35 kg m -2 ) who were not following any specific diet, and were given placebo or BGCC (3 g d -1 ) for 12 weeks. Results were analysed by intention-to-treat (ITT) and per-protocol (PP) methods. Body weight increased in the placebo group compared to baseline (ITT: 1.0 kg, P < 0.001; PP: 1.5 kg, P = 0.003), while it was slightly lowered in the BGCC group (ITT: -0.8 kg, P = 0.210; PP: -1.1 kg, P = 0.182). BGCC, but not the consumption of placebo, also resulted in a reduction of waist circumference and body fat compared to baseline. Results suggest that daily supplementation of BGCC may be useful for improving body weight and waist circumference in overweight and obese subjects, without relevant adverse effects. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Brunelli, Alessandro; Salati, Michele; Refai, Majed; Di Nunzio, Luca; Xiumé, Francesco; Sabbatini, Armando
2010-01-01
The objective of this randomised trial was to assess the effectiveness of a new fast-track chest tube removal protocol taking advantage of digital monitoring of air leak compared to a traditional protocol using visual and subjective assessment of air leak (bubbles). One hundred and sixty-six patients submitted to pulmonary lobectomy for lung cancer were randomised in two groups with different chest tube removal protocols: (1) in the new protocol, chest tube was removed based on digitally recorded measurements of air leak flow; (2) in the traditional protocol, the chest tube removal was based on an instantaneous assessment of air leak during daily rounds. The two groups were compared in terms of chest tube duration, hospital stay and costs. The two groups were well matched for several preoperative and operative variables. Compared to the traditional protocol, the new digital recording protocol showed mean reductions in chest tube duration (p=0.0007), hospital stay (p=0.007) of 0.9 day, and a mean cost saving of euro 476 per patient (p=0.008). In the new chest tube removal protocol, 51% of patients had their chest tube removed by the second postoperative day versus only 12% of those in the traditional protocol. The application of a chest tube removal protocol using a digital drainage unit featuring a continuous recording of air leak was safe and cost effective. Although future studies are warranted to confirm these results in other settings, the use of this new protocol is now routinely applied in our practice. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Comparing Usual Care With a Warfarin Initiation Protocol After Mechanical Heart Valve Replacement.
Roberts, Gregory; Razooqi, Rasha; Quinn, Stephen
2017-03-01
The immediate postoperative warfarin sensitivity for patients receiving heart valve prostheses is increased. Established warfarin initiation protocols may lack clinical applicability, resulting in dosing based on clinical judgment. To compare current practice for warfarin initiation with a known warfarin initiation protocol, with doses proportionally reduced to account for the increased postoperative sensitivity. We compared the Mechanical Heart Valve Warfarin Initiation Protocol (Protocol group) with current practice (clinical judgment-Empirical group) for patients receiving mechanical heart valves in an observational before-and-after format. End points were the time to achieve a stable therapeutic international normalized ratio (INR), doses held in the first 6 days, and overanticoagulation in the first 6 days. The Protocol group (n = 37) achieved a stable INR more rapidly than the Empirical group (n = 77; median times 5.1 and 8.7 days, respectively; P = 0.002). Multivariable analysis indicated that the Protocol group (hazard ratio [HR] = 2.22; P = 0.005) and men (HR = 1.76; P = 0.043) more rapidly achieved a stable therapeutic INR. Age, serum albumin, amiodarone, presence of severe heart failure, and surgery type had no impact. Protocol patients had fewer doses held (1.1% vs 10.1%, P < 0.001) and no difference in overanticoagulation (2.7% vs 9.1%, P = 0.27). The Mechanical Heart Valve Warfarin Initiation Protocol provided a reliable approach to initiating warfarin in patients receiving mechanical aortic or mitral valves.
Mayfield, Erin N; Norman, Catherine Shelley
2012-09-15
We examine the progress of the phaseout of the use of the pesticide methyl bromide in the production of California field strawberries. This phaseout is required under the Montreal Protocol and has been contentious in this sector, which receives exemptions from the schedule initially agreed under the treaty, and in international negotiations over the future of the Protocol. We examine the various ex-ante predictions of the impacts on growers, consumers and trade patterns in light of several years of declining allocations under the Critical Use provisions of the Protocol and the 2010 approval of iodomethane for use in California and subsequent 2012 withdrawal of this alternative from the US market. We find that, contrary to ex-ante industry claims, the years of declining methyl bromide use have been years of rising yields, acreage, exports, revenues and market share for California growers, even when faced with a global recession and increased imports from Mexican growers who retain the right to use the chemical under the Protocol. This has implications for the Protocol as a whole and for the remainder of the US phaseout of this chemical in particular. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhao, F.; Frieler, K.; Warszawski, L.; Lange, S.; Schewe, J.; Reyer, C.; Ostberg, S.; Piontek, F.; Betts, R. A.; Burke, E.; Ciais, P.; Deryng, D.; Ebi, K. L.; Emanuel, K.; Elliott, J. W.; Galbraith, E. D.; Gosling, S.; Hickler, T.; Hinkel, J.; Jones, C.; Krysanova, V.; Lotze-Campen, H.; Mouratiadou, I.; Popp, A.; Tian, H.; Tittensor, D.; Vautard, R.; van Vliet, M. T. H.; Eddy, T.; Hattermann, F.; Huber, V.; Mengel, M.; Stevanovic, M.; Kirsten, T.; Mueller Schmied, H.; Denvil, S.; Halladay, K.; Suzuki, T.; Lotze, H. K.
2016-12-01
In Paris, France, December 2015 the Conference of Parties (COP) to the United Nations Framework Convention on Climate Change (UNFCCC) invited the IPCC to provide a "special report in 2018 on the impacts of global warming of 1.5°C above pre-industrial levels and related global greenhouse gas emission pathways". In Nairobi, Kenya, April 2016 the IPCC panel accepted the invitation. Here we describe the model simulations planned within the Inter-Sectoral Impact Model Intercomparison Project (ISIMIP) to address the request by providing tailored cross-sectoral consistent impacts projections. The protocol is designed to allow for 1) a separation of the impacts of the historical warming starting from pre-industrial conditions from other human drivers such as historical land use changes (based on pre-industrial and historical impact model simulations), 2) a quantification of the effects of an additional warming to 1.5°C including a potential overshoot and long term effects up to 2300 in comparison to a no-mitigation scenario (based on the low emissions Representative Concentration Pathway RCP2.6 and a no-mitigation scenario RCP6.0) keeping socio-economic conditions fixed at year 2005 levels, and 3) an assessment of the climate effects based on the same climate scenarios but accounting for parallel changes in socio-economic conditions following the middle of the road Shared Socioeconomic Pathway (SSP2) and differential bio-energy requirements associated with the transformation of the energy system to reach RCP2.6 compared to RCP6.0. To provide the scientific basis for an aggregation of impacts across sectors and an analysis of cross-sectoral interactions potentially damping or amplifying sectoral impacts the protocol is designed to provide consistent impacts projections across a range of impact models from different sectors (global and regional hydrological models, global gridded crop models, global vegetation models, regional forestry models, global and regional marine ecosystem and fisheries models, global and regional coastal infrastructure models, energy models, health models, and agro-economic models).
NASA Astrophysics Data System (ADS)
Frieler, Katja; Warszawski, Lila; Zhao, Fang
2017-04-01
In Paris, France, December 2015 the Conference of Parties (COP) to the United Nations Framework Convention on Climate Change (UNFCCC) invited the IPCC to provide a "special report in 2018 on the impacts of global warming of 1.5°C above pre-industrial levels and related global greenhouse gas emission pathways". In Nairobi, Kenya, April 2016 the IPCC panel accepted the invitation. Here we describe the model simulations planned within the Inter-Sectoral Impact Model Intercomparison Project (ISIMIP) to address the request by providing tailored cross-sectoral consistent impacts projections. The protocol is designed to allow for 1) a separation of the impacts of the historical warming starting from pre-industrial conditions from other human drivers such as historical land use changes (based on pre-industrial and historical impact model simulations), 2) a quantification of the effects of an additional warming to 1.5°C including a potential overshoot and long term effects up to 2300 in comparison to a no-mitigation scenario (based on the low emissions Representative Concentration Pathway RCP2.6 and a no-mitigation scenario RCP6.0) keeping socio-economic conditions fixed at year 2005 levels, and 3) an assessment of the climate effects based on the same climate scenarios but accounting for parallel changes in socio-economic conditions following the middle of the road Shared Socioeconomic Pathway (SSP2) and differential bio-energy requirements associated with the transformation of the energy system to reach RCP2.6 compared to RCP6.0. To provide the scientific basis for an aggregation of impacts across sectors and an analysis of cross-sectoral interactions potentially damping or amplifying sectoral impacts the protocol is designed to provide consistent impacts projections across a range of impact models from different sectors (global and regional hydrological models, global gridded crop models, global vegetation models, regional forestry models, global and regional marine ecosystem and fisheries models, global and regional coastal infrastructure models, energy models, health models, and agro-economic models).
NEW APPROACHES TO ESTIMATION OF SOLID-WASTE QUANTITY AND COMPOSITION
Efficient and statistically sound sampling protocols for estimating the quantity and composition of solid waste over a stated period of time in a given location, such as a landfill site or at a specific point in an industrial or commercial process, are essential to the design ...
PROTOCOL - A COMPUTERIZED SOLID WASTE QUANTITY AND COMPOSITION ESTIMATION SYSTEM: OPERATIONAL MANUAL
The assumptions of traditional sampling theory often do not fit the circumstances when estimating the quantity and composition of solid waste arriving at a given location, such as a landfill site, or at a specific point in an industrial or commercial process. The investigator oft...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 15 Commerce and Foreign Trade 2 2014-01-01 2014-01-01 false Hearings. 785.12 Section 785.12... INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.12 Hearings. (a) Scheduling. Upon receipt of a valid request for a hearing, the ALJ shall, by agreement with all...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Hearings. 785.12 Section 785.12... INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.12 Hearings. (a) Scheduling. Upon receipt of a valid request for a hearing, the ALJ shall, by agreement with all...
Hardware Realization of an Ethernet Packet Analyzer Search Engine
2000-06-30
specific for the home automation industry. This analyzer will be at the gateway of a network and analyze Ethernet packets as they go by. It will keep... home automation and not the computer network. This system is a stand-alone real-time network analyzer capable of decoding Ethernet protocols. The
15 CFR 782.1 - Overview of reporting requirements under the APR.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Overview of reporting requirements under the APR. 782.1 Section 782.1 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL...
Protocol for introducing new and licensed citrus varieties into California. A Florida case study.
USDA-ARS?s Scientific Manuscript database
In the light of the current Huanglongbing (HLB) threat to the California (CA) citrus industry, and preliminary data indicating that some citrus varieties in Florida (FL) may possess some degree of tolerance to HLB, the California citrus growers indicated a strong interest in proactively introducing ...
15 CFR 785.4 - Request for hearing and answer.
Code of Federal Regulations, 2014 CFR
2014-01-01
...) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785... respondent's defense(s). The answer must specifically admit or deny each separate allegation in the NOVA; if... a defense or claim of mitigation. Any defense or partial defense not specifically set forth in the...
15 CFR 785.4 - Request for hearing and answer.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785... respondent's defense(s). The answer must specifically admit or deny each separate allegation in the NOVA; if... a defense or claim of mitigation. Any defense or partial defense not specifically set forth in the...
15 CFR 785.4 - Request for hearing and answer.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785... respondent's defense(s). The answer must specifically admit or deny each separate allegation in the NOVA; if... a defense or claim of mitigation. Any defense or partial defense not specifically set forth in the...
15 CFR 785.4 - Request for hearing and answer.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785... respondent's defense(s). The answer must specifically admit or deny each separate allegation in the NOVA; if... a defense or claim of mitigation. Any defense or partial defense not specifically set forth in the...
15 CFR 785.4 - Request for hearing and answer.
Code of Federal Regulations, 2013 CFR
2013-01-01
...) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785... respondent's defense(s). The answer must specifically admit or deny each separate allegation in the NOVA; if... a defense or claim of mitigation. Any defense or partial defense not specifically set forth in the...
77 FR 12622 - Records Schedules; Availability and Request for Comments
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-01
... chemical weapons convention program records and protocol program records. 3. Department of Defense, Defense... disposition process is available on request. Schedules Pending 1. Department of the Army, Agency-wide (N1-AU... programs, housing, recreation, and travel. 2. Department of Commerce, Bureau of Industry and Security, (N1...
Standby Power Management Architecture for Deep-Submicron Systems
2006-05-19
Driver 61 5.1 Quark PicoNode System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 5.2 Power Domain Architecture... Quark system protocol stack. . . . . . . . . . . . . . . . . . . . . . . . . . . 62 5.2 Quark system block diagram...the implementation of the chip using an industry-standard place and route design flow. Lastly some measurements from the chip are presented. 5.1 Quark
15 CFR 782.4 - Assistance in determining your obligations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Assistance in determining your obligations. 782.4 Section 782.4 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS GENERAL...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-11
... circumstances where dissemination may mislead or confuse investors and other market participants. In addition... data elements are updated.\\12\\ In disseminated data, market participants will cross-reference the RDID... are rounded or truncated. The dissemination protocol to provide an RDID that market participants will...
Ethoxylated alcohols, alkylphenols, and acrylamide are emerging contaminants with many different routes into the environment. Ethoxylated alcohols are used ubiquitously as surfactants in both industrial and household products. The use of ethoxylated alcohols and alkylphenols as s...
Virulence and molecular variation of Flavobacterium columnare affecting rainbow trout in ID, USA
USDA-ARS?s Scientific Manuscript database
Columnaris disease is an emerging problem in the rainbow trout (Oncorhychus mykiss) aquaculture industry of Idaho. The epidemiology of this pathogen in the area, and for rainbow trout, is all isolates taken from disease outbreaks are genomovar I and similar based on basic typing protocols. Virulence...
Ultrafast Brain MRI: Clinical Deployment and Comparison to Conventional Brain MRI at 3T.
Prakkamakul, Supada; Witzel, Thomas; Huang, Susie; Boulter, Daniel; Borja, Maria J; Schaefer, Pamela; Rosen, Bruce; Heberlein, Keith; Ratai, Eva; Gonzalez, Gilberto; Rapalino, Otto
2016-09-01
To compare an ultrafast brain magnetic resonance imaging (MRI) protocol to the conventional protocol in motion-prone inpatient clinical settings. This retrospective study was HIPAA compliant and approved by the Institutional Review Board with waived inform consent. Fifty-nine inpatients (30 males, 29 females; mean age 55.1, range 23-93 years)who underwent 3-Tesla brain MRI using ultrafast and conventional protocols, both including five sequences, were included in the study. The total scan time for five ultrafast sequences was 4 minutes 59 seconds. The ideal conventional acquisition time was 10 minutes 32 seconds but the actual acquisition took 15-20 minutes. The average scan times for ultrafast localizers, T1-weighted, T2-weighted, fluid-attenuated inversion recovery (FLAIR), diffusion-weighted, T2*-weighted sequences were 14, 41, 62, 96, 80, 6 seconds, respectively. Two blinded neuroradiologists independently assessed three aspects: (1) image quality, (2) gray-white matter (GM-WM) differentiation, and (3) diagnostic concordance for the detection of six clinically relevant imaging findings. Wilcoxon signed-rank test was used to compare image quality and GM-WM scores. Interobserver reproducibility was calculated. The ultrafast T1-weighted sequence demonstrated significantly better image quality (P = .005) and GM-WM differentiation (P < .001) compared to the conventional sequence. There was high agreement (>85%) between both protocols for the detection of mass-like lesion, hemorrhage, diffusion restriction, WM FLAIR hyperintensities, subarachnoid FLAIR hyperintensities, and hydrocephalus. The ultrafast protocol achieved at least comparable image quality and high diagnostic concordance compared to the conventional protocol. This fast protocol can be a viable option to replace the conventional protocol in motion-prone inpatient clinical settings. Copyright © 2016 by the American Society of Neuroimaging.
Comparison of protocols measuring diffusion and partition coefficients in the stratum corneum.
Rothe, H; Obringer, C; Manwaring, J; Avci, C; Wargniez, W; Eilstein, J; Hewitt, N; Cubberley, R; Duplan, H; Lange, D; Jacques-Jamin, C; Klaric, M; Schepky, A; Grégoire, S
2017-07-01
Partition (K) and diffusion (D) coefficients are important to measure for the modelling of skin penetration of chemicals through the stratum corneum (SC). We compared the feasibility of three protocols for the testing of 50 chemicals in our main studies, using three cosmetics-relevant model chemicals with a wide range of logP values. Protocol 1: SC concentration-depth profile using tape-stripping (measures K SC/v and D SC /H SC 2 , where H SC is the SC thickness); Protocol 2A: incubation of isolated SC with chemical (direct measurement of K SC/v only) and Protocol 2B: diffusion through isolated SC mounted on a Franz cell (measures K SC/v and D SC /H SC 2 , and is based on Fick's laws). K SC/v values for caffeine and resorcinol using Protocol 1 and 2B were within 30% of each other, values using Protocol 2A were ~two-fold higher, and all values were within 10-fold of each other. Only indirect determination of K SC/v by Protocol 2B was different from the direct measurement of K SC/v by Protocol 2A and Protocol 1 for 7-EC. The variability of K SC/v for all three chemicals using Protocol 2B was higher compared to Protocol 1 and 2A. D SC /H SC 2 values for the three chemicals were of the same order of magnitude using all three protocols. Additionally, using Protocol 1, there was very little difference between parameters measured in pig and human SC. In conclusion, K SC/v, and D SC values were comparable using different methods. Pig skin might be a good surrogate for human skin for the three chemicals tested. Copyright © 2017 The Authors Journal of Applied Toxicology published by John Wiley & Sons Ltd. Copyright © 2017 The Authors Journal of Applied Toxicology published by John Wiley & Sons Ltd.
Vedula, S Swaroop; Li, Tianjing; Dickersin, Kay
2013-01-01
Details about the type of analysis (e.g., intent to treat [ITT]) and definitions (i.e., criteria for including participants in the analysis) are necessary for interpreting a clinical trial's findings. Our objective was to compare the description of types of analyses and criteria for including participants in the publication (i.e., what was reported) with descriptions in the corresponding internal company documents (i.e., what was planned and what was done). Trials were for off-label uses of gabapentin sponsored by Pfizer and Parke-Davis, and documents were obtained through litigation. For each trial, we compared internal company documents (protocols, statistical analysis plans, and research reports, all unpublished), with publications. One author extracted data and another verified, with a third person verifying discordant items and a sample of the rest. Extracted data included the number of participants randomized and analyzed for efficacy, and types of analyses for efficacy and safety and their definitions (i.e., criteria for including participants in each type of analysis). We identified 21 trials, 11 of which were published randomized controlled trials, and that provided the documents needed for planned comparisons. For three trials, there was disagreement on the number of randomized participants between the research report and publication. Seven types of efficacy analyses were described in the protocols, statistical analysis plans, and publications, including ITT and six others. The protocol or publication described ITT using six different definitions, resulting in frequent disagreements between the two documents (i.e., different numbers of participants were included in the analyses). Descriptions of analyses conducted did not agree between internal company documents and what was publicly reported. Internal company documents provide extensive documentation of methods planned and used, and trial findings, and should be publicly accessible. Reporting standards for randomized controlled trials should recommend transparent descriptions and definitions of analyses performed and which study participants are excluded.
Jonker, Dirk; Gustafsson, Ewa; Rolander, Bo; Arvidsson, Inger; Nordander, Catarina
2015-01-01
A new health surveillance protocol for work-related upper-extremity musculoskeletal disorders has been validated by comparing the results with a reference protocol. The studied protocol, Health Surveillance in Adverse Ergonomics Conditions (HECO), is a new version of the reference protocol modified for application in the Occupational Health Service (OHS). The HECO protocol contains both a screening part and a diagnosing part. Sixty-three employees were examined. The screening in HECO did not miss any diagnosis found when using the reference protocol, but in comparison to the reference protocol considerable time savings could be achieved. Fair to good agreement between the protocols was obtained for one or more diagnoses in neck/shoulders (86%, k = 0.62) and elbow/hands (84%, k = 0.49). Therefore, the results obtained using the HECO protocol can be compared with a reference material collected with the reference protocol, and thus provide information of the magnitude of disorders in an examined work group. Practitioner Summary: The HECO protocol is a relatively simple physical examination protocol for identification of musculoskeletal disorders in the neck and upper extremities. The protocol is a reliable and cost-effective tool for the OHS to use for occupational health surveillance in order to detect workplaces at high risk for developing musculoskeletal disorders. PMID:25761380
Villalón-López, Nayelli; Serrano-Contreras, José I; Téllez-Medina, Darío I; Gerardo Zepeda, L
2018-04-01
The present non-targeted 1 H NMR-based fingerprinting approach along with multivariate analysis established differences between representative aqueous extracts of commercial ground roasted coffee (GRC) and instant (soluble) coffee (IC) samples. The latter were prepared either by spray drying or freeze drying. When comparing a total of 33 compounds between GRC and IC, the latter product contained a remarkable increase in 5-(hydroxymethyl)furfural and carbohydrates, as well as a clear decrease in trigonelline, N-methylpyridinium, caffeine, caffeoylquinic acids and 2-furylmethanol. Furthermore, the current protocol was able to detect the subtle chemical differences between spray-dried and freeze-dried IC. The aforementioned metabolites could serve as target molecules in the attempt to preserve, as much as possible, the organoleptic and nutraceutical properties of GRC during the industrial drying processes used in the production of the two commercial types of IC. Copyright © 2018 Elsevier Ltd. All rights reserved.
Coelho, F; Aguiar, L F; Cunha, G S P; Cardinot, N; Lucena, E
2014-01-01
The ovarian stimulation has been applied in order to increase the number of oocytes to compensate for the poor results of in vitro fertilization, allowing the selection of one or more embryos to be transferred. Our aim is to compare the results obtained in IVF/ICSI cycles using the short protocol for controlled ovarian stimulation to the results from the modified mild protocol used in our department. A total of 240 cycles were conducted from January 2010 to December 2011. When comparing both protocols, it could be observed that there was a significant difference in the quantity of gonadotropins doses in the mild protocol and in the short protocol. No significant difference was observed regarding pregnancy rates per cycle, 22% and 26.2%, in short and mild protocols, respectively. The protocols of controlled ovarian stimulation are often associated with high risk of complications such as ovarian hyperstimulation syndrome, excessive emotional stress, high rates of treatment dropouts, and abdominal discomfort. With the data obtained in this study, one can conclude that there are less risks and complications for the patient when using the mild stimulation protocol. It was also observed that in this group there was a slightly higher rate.
Zdrazil, B.; Neefs, J.-M.; Van Vlijmen, H.; Herhaus, C.; Caracoti, A.; Brea, J.; Roibás, B.; Loza, M. I.; Queralt-Rosinach, N.; Furlong, L. I.; Gaulton, A.; Bartek, L.; Senger, S.; Chichester, C.; Engkvist, O.; Evelo, C. T.; Franklin, N. I.; Marren, D.; Ecker, G. F.
2016-01-01
Phenotypic screening is in a renaissance phase and is expected by many academic and industry leaders to accelerate the discovery of new drugs for new biology. Given that phenotypic screening is per definition target agnostic, the emphasis of in silico and in vitro follow-up work is on the exploration of possible molecular mechanisms and efficacy targets underlying the biological processes interrogated by the phenotypic screening experiments. Herein, we present six exemplar computational protocols for the interpretation of cellular phenotypic screens based on the integration of compound, target, pathway, and disease data established by the IMI Open PHACTS project. The protocols annotate phenotypic hit lists and allow follow-up experiments and mechanistic conclusions. The annotations included are from ChEMBL, ChEBI, GO, WikiPathways and DisGeNET. Also provided are protocols which select from the IUPHAR/BPS Guide to PHARMACOLOGY interaction file selective compounds to probe potential targets and a correlation robot which systematically aims to identify an overlap of active compounds in both the phenotypic as well as any kinase assay. The protocols are applied to a phenotypic pre-lamin A/C splicing assay selected from the ChEMBL database to illustrate the process. The computational protocols make use of the Open PHACTS API and data and are built within the Pipeline Pilot and KNIME workflow tools. PMID:27774140
Bapodra, Priya; Cracknell, Jonathan; Wolfe, Barbara A
2014-03-01
Three adult and two subadult greater one-horned rhinoceroses (Rhinoceros unicornis) were sedated a total of nine times using two different intramuscular sedative combinations in order to compare the effectiveness of these combinations in inducing consistent standing sedation in this species. The sedation protocols compared were butorphanol tartrate (50-60 mg) and detomidine hydrochloride (20-30 mg; BD) versus butorphanol tartrate (80-120 mg) and azaperone (80-120 mg; BA). Specific doses were adjusted according to age and sex class, and based on previous experience. Parameters compared included time to achieve defined levels of sedation, time to recovery following antagonism, physiological parameters including heart rate, respiratory rate, indirect arterial blood pressure, and venous blood gas values. A hydraulic restraint chute was utilized to mechanically restrain animals during the procedures, and blood collection and ophthalmic examinations were conducted on all animals. Both protocols resulted in standing sedation for > or = 22.3 +/- 2.9 min or until antagonists were administered. The BD protocol resulted in deeper and more consistent sedation, compared to the BA protocol. Naltrexone hydrochloride (250-300 mg) and tolazoline hydrochloride (1,500-2,000 mg) were administered intramuscularly to antagonize protocol BD, whereas naltrexone alone (200-500 mg) was used to antagonize BA. Time to full antagonism, defined as normal mentation and ambulation following administration of antagonists, was prolonged in the BD protocol (132.3 +/- 17.2 min) compared with the BA protocol (7.5 +/- 2.5 min). Venous blood gas analysis did not reveal any significant blood gas deviations during sedation when compared with either conscious equine or white rhinoceros (Ceratotherium simum) venous reference ranges. In summary, both combinations resulted in adequate standing sedation for minimally invasive procedures, although BD resulted in more profound and consistent sedation.
Framework for managing mycotoxin risks in the food industry.
Baker, Robert C; Ford, Randall M; Helander, Mary E; Marecki, Janusz; Natarajan, Ramesh; Ray, Bonnie
2014-12-01
We propose a methodological framework for managing mycotoxin risks in the food processing industry. Mycotoxin contamination is a well-known threat to public health that has economic significance for the food processing industry; it is imperative to address mycotoxin risks holistically, at all points in the procurement, processing, and distribution pipeline, by tracking the relevant data, adopting best practices, and providing suitable adaptive controls. The proposed framework includes (i) an information and data repository, (ii) a collaborative infrastructure with analysis and simulation tools, (iii) standardized testing and acceptance sampling procedures, and (iv) processes that link the risk assessments and testing results to the sourcing, production, and product release steps. The implementation of suitable acceptance sampling protocols for mycotoxin testing is considered in some detail.
W. Sutton; E.M. Hansen; P. Reeser; A. Kanaskie
2008-01-01
Oregon was a participant in the pilot test of the national stream monitoring protocol for SOD. We routinely and continuously monitor about 50 streams in and near the SOD quarantine area in southwest Oregon using foliage baits. For the national protocol, we added six additional streams beyond the area of known infestation, and compared results from different diagnostic...
ERIC Educational Resources Information Center
Paez-Blarrina, Marisa; Luciano, Carmen; Gutierrez-Martinez, Olga; Valdivia, Sonsoles; Rodriguez-Valverde, Miguel; Ortega, Jose
2008-01-01
This study compares the effect of an acceptance-based protocol (ACT) and a cognitive control-based (CONT) protocol on three measures of pain coping: tolerance, self-report, and believability. Specific methodological controls were employed to further isolate the role of the value of participating in a pain task, compared to previous investigations…
van der Heijden, Amber A W A; de Bruijne, Martine C; Feenstra, Talitha L; Dekker, Jacqueline M; Baan, Caroline A; Bosmans, Judith E; Bot, Sandra D M; Donker, Gé A; Nijpels, Giel
2014-06-25
The increasing prevalence of diabetes is associated with increased health care use and costs. Innovations to improve the quality of care, manage the increasing demand for health care and control the growth of health care costs are needed. The aim of this study is to evaluate the care process and costs of managed, protocolized and usual care for type 2 diabetes patients from a societal perspective. In two distinct regions of the Netherlands, both managed and protocolized diabetes care were implemented. Managed care was characterized by centralized organization, coordination, responsibility and centralized annual assessment. Protocolized care had a partly centralized organizational structure. Usual care was characterized by a decentralized organizational structure. Using a quasi-experimental control group pretest-posttest design, the care process (guideline adherence) and costs were compared between managed (n = 253), protocolized (n = 197), and usual care (n = 333). We made a distinction between direct health care costs, direct non-health care costs and indirect costs. Multivariate regression models were used to estimate differences in costs adjusted for confounding factors. Because of the skewed distribution of the costs, bootstrapping methods (5000 replications) with a bias-corrected and accelerated approach were used to estimate 95% confidence intervals (CI) around the differences in costs. Compared to usual and protocolized care, in managed care more patients were treated according to diabetes guidelines. Secondary health care use was higher in patients under usual care compared to managed and protocolized care. Compared to usual care, direct costs were significantly lower in managed care (€-1.181 (95% CI: -2.597 to -334)) while indirect costs were higher (€ 758 (95% CI: -353 to 2.701), although not significant. Direct, indirect and total costs were lower in protocolized care compared to usual care (though not significantly). Compared to usual care, managed care was significantly associated with better process in terms of diabetes care, fewer secondary care consultations and lower health care costs. The same trends were seen for protocolized care, however they were not statistically significant. Current Controlled trials: ISRCTN66124817.
2014-01-01
Background The increasing prevalence of diabetes is associated with increased health care use and costs. Innovations to improve the quality of care, manage the increasing demand for health care and control the growth of health care costs are needed. The aim of this study is to evaluate the care process and costs of managed, protocolized and usual care for type 2 diabetes patients from a societal perspective. Methods In two distinct regions of the Netherlands, both managed and protocolized diabetes care were implemented. Managed care was characterized by centralized organization, coordination, responsibility and centralized annual assessment. Protocolized care had a partly centralized organizational structure. Usual care was characterized by a decentralized organizational structure. Using a quasi-experimental control group pretest-posttest design, the care process (guideline adherence) and costs were compared between managed (n = 253), protocolized (n = 197), and usual care (n = 333). We made a distinction between direct health care costs, direct non-health care costs and indirect costs. Multivariate regression models were used to estimate differences in costs adjusted for confounding factors. Because of the skewed distribution of the costs, bootstrapping methods (5000 replications) with a bias-corrected and accelerated approach were used to estimate 95% confidence intervals (CI) around the differences in costs. Results Compared to usual and protocolized care, in managed care more patients were treated according to diabetes guidelines. Secondary health care use was higher in patients under usual care compared to managed and protocolized care. Compared to usual care, direct costs were significantly lower in managed care (€-1.181 (95% CI: -2.597 to -334)) while indirect costs were higher (€758 (95% CI: -353 to 2.701), although not significant. Direct, indirect and total costs were lower in protocolized care compared to usual care (though not significantly). Conclusions Compared to usual care, managed care was significantly associated with better process in terms of diabetes care, fewer secondary care consultations and lower health care costs. The same trends were seen for protocolized care, however they were not statistically significant. Trial registration Current Controlled trials: ISRCTN66124817. PMID:24966055
Lelijveld, Natasha; Bailey, Jeanette; Mayberry, Amy; Trenouth, Lani; N'Diaye, Dieynaba S; Haghparast-Bidgoli, Hassan; Puett, Chloe
2018-04-24
Acute malnutrition is currently divided into severe (SAM) and moderate (MAM) based on level of wasting. SAM and MAM currently have separate treatment protocols and products, managed by separate international agencies. For SAM, the dose of treatment is allocated by the child's weight. A combined and simplified protocol for SAM and MAM, with a standardised dose of ready-to-use therapeutic food (RUTF), is being trialled for non-inferior recovery rates and may be more cost-effective than the current standard protocols for treating SAM and MAM. This is the protocol for the economic evaluation of the ComPAS trial, a cluster-randomised controlled, non-inferiority trial that compares a novel combined protocol for treating uncomplicated acute malnutrition compared to the current standard protocol in South Sudan and Kenya. We will calculate the total economic costs of both protocols from a societal perspective, using accounting data, interviews and survey questionnaires. The incremental cost of implementing the combined protocol will be estimated, and all costs and outcomes will be presented as a cost-consequence analysis. Incremental cost-effectiveness ratio will be calculated for primary and secondary outcome, if statistically significant. We hypothesise that implementing the combined protocol will be cost-effective due to streamlined logistics at clinic level, reduced length of treatment, especially for MAM, and reduced dosages of RUTF. The findings of this economic evaluation will be important for policymakers, especially given the hypothesised non-inferiority of the main health outcomes. The publication of this protocol aims to improve rigour of conduct and transparency of data collection and analysis. It is also intended to promote inclusion of economic evaluation in other nutrition intervention studies, especially for MAM, and improve comparability with other studies. ISRCTN 30393230 , date: 16/03/2017.
Karády, Júlia; Panajotu, Alexisz; Kolossváry, Márton; Szilveszter, Bálint; Jermendy, Ádám L; Bartykowszki, Andrea; Károlyi, Mihály; Celeng, Csilla; Merkely, Béla; Maurovich-Horvat, Pál
2017-11-01
Contrast media (CM) extravasation is a well-known complication of CT angiography (CTA). Our prospective randomized control study aimed to assess whether a four-phasic CM administration protocol reduces the risk of extravasation compared to the routinely used three-phasic protocol in coronary CTA. Patients referred to coronary CTA due to suspected coronary artery disease were included in the study. All patients received 400 mg/ml iomeprol CM injected with dual-syringe automated injector. Patients were randomized into a three-phasic injection-protocol group, with a CM bolus of 85 ml followed by 40 ml of 75%:25% saline/CM mixture and 30 ml saline chaser bolus; and a four-phasic injection-protocol group, with a saline pacer bolus of 10 ml injected at a lower flow rate before the three-phasic protocol. 2,445 consecutive patients were enrolled (mean age 60.6 ± 12.1 years; females 43.6%). Overall rate of extravasation was 0.9% (23/2,445): 1.4% (17/1,229) in the three-phasic group and 0.5% (6/1,216) in the four-phasic group (p = 0.034). Four-phasic CM administration protocol is easy to implement in the clinical routine at no extra cost. The extravasation rate is reduced by 65% with the application of the four-phasic protocol compared to the three-phasic protocol in coronary CTA. • Four-phasic CM injection-protocol reduces extravasation rate by 65% compared to three-phasic. • The saline pacer bolus substantially reduces the risk of CM extravasation. • The implementation of four-phasic injection-protocol is at no cost.
Anitua, Eduardo; Prado, Roberto; Troya, María; Zalduendo, Mar; de la Fuente, María; Pino, Ander; Muruzabal, Francisco; Orive, Gorka
2016-07-01
Plasma rich in growth factors (PRGF) is a biological therapy that uses patient's own growth factors for promoting tissue regeneration. Given the current European regulatory framework in which anticoagulant solution in blood extraction tubes could be considered as a medicinal product, a new PRGF protocol has been developed. The actual protocol (PRGF-A) and the new one (PRGF-B) have been performed and compared under Good Laboratory Practices. PRGF-A protocol uses extraction tubes with 0.9 mL of trisodium citrate as anticoagulant and 50 μL of calcium chloride/mL PRGF to activate it. The PRGF-B reduces the amount of sodium citrate and calcium chloride to 0.4 mL and to 20 μL, respectively. Basic hematological parameters, platelet function, the scaffold obtaining process, growth factors content, and the biological effect were compared between both PRGF obtaining protocols. PRGF-B protocol led to a statistically significant higher enrichment and recovery of platelets regarding to the PRGF-A. Hypotonic stress response by platelets was significantly better in the new protocol. A statistically significant decrease in the basal platelet activation status of PRGF-B compared to PRGF-A was also observed. The duration of the lag phase in the platelet aggregation assay was statistically lower for the PRGF-B protocol. Both the clotting and the clot retraction time were significantly reduced in the B protocol. A higher growth factor concentration was detected in the plasma obtained using the PRGF-B protocol. The new PRGF obtaining protocol, with a reduction in the amount of anticoagulant and activator, has even improved the actual one.
Use of IPsec by Manned Space Missions
NASA Technical Reports Server (NTRS)
Pajevski, Michael J.
2009-01-01
NASA's Constellation Program is developing its next generation manned space systems for missions to the International Space Station (ISS) and the Moon. The Program is embarking on a path towards standards based Internet Protocol (IP) networking for space systems communication. The IP based communications will be paired with industry standard security mechanisms such as Internet Protocol Security (IPsec) to ensure the integrity of information exchanges and prevent unauthorized release of sensitive information in-transit. IPsec has been tested in simulations on the ground and on at least one Earth orbiting satellite, but the technology is still unproven in manned space mission situations and significant obstacles remain.
A comparative study of wireless sensor networks and their routing protocols.
Bhattacharyya, Debnath; Kim, Tai-hoon; Pal, Subhajit
2010-01-01
Recent developments in the area of micro-sensor devices have accelerated advances in the sensor networks field leading to many new protocols specifically designed for wireless sensor networks (WSNs). Wireless sensor networks with hundreds to thousands of sensor nodes can gather information from an unattended location and transmit the gathered data to a particular user, depending on the application. These sensor nodes have some constraints due to their limited energy, storage capacity and computing power. Data are routed from one node to other using different routing protocols. There are a number of routing protocols for wireless sensor networks. In this review article, we discuss the architecture of wireless sensor networks. Further, we categorize the routing protocols according to some key factors and summarize their mode of operation. Finally, we provide a comparative study on these various protocols.
An Efficient Wireless Sensor Network for Industrial Monitoring and Control.
Aponte-Luis, Juan; Gómez-Galán, Juan Antonio; Gómez-Bravo, Fernando; Sánchez-Raya, Manuel; Alcina-Espigado, Javier; Teixido-Rovira, Pedro Miguel
2018-01-10
This paper presents the design of a wireless sensor network particularly designed for remote monitoring and control of industrial parameters. The article describes the network components, protocol and sensor deployment, aimed to accomplish industrial constraint and to assure reliability and low power consumption. A particular case of study is presented. The system consists of a base station, gas sensing nodes, a tree-based routing scheme for the wireless sensor nodes and a real-time monitoring application that operates from a remote computer and a mobile phone. The system assures that the industrial safety quality and the measurement and monitoring system achieves an efficient industrial monitoring operations. The robustness of the developed system and the security in the communications have been guaranteed both in hardware and software level. The system is flexible and can be adapted to different environments. The testing of the system confirms the feasibility of the proposed implementation and validates the functional requirements of the developed devices, the networking solution and the power consumption management.
An Efficient Wireless Sensor Network for Industrial Monitoring and Control
Aponte-Luis, Juan; Gómez-Bravo, Fernando; Sánchez-Raya, Manuel; Alcina-Espigado, Javier; Teixido-Rovira, Pedro Miguel
2018-01-01
This paper presents the design of a wireless sensor network particularly designed for remote monitoring and control of industrial parameters. The article describes the network components, protocol and sensor deployment, aimed to accomplish industrial constraint and to assure reliability and low power consumption. A particular case of study is presented. The system consists of a base station, gas sensing nodes, a tree-based routing scheme for the wireless sensor nodes and a real-time monitoring application that operates from a remote computer and a mobile phone. The system assures that the industrial safety quality and the measurement and monitoring system achieves an efficient industrial monitoring operations. The robustness of the developed system and the security in the communications have been guaranteed both in hardware and software level. The system is flexible and can be adapted to different environments. The testing of the system confirms the feasibility of the proposed implementation and validates the functional requirements of the developed devices, the networking solution and the power consumption management. PMID:29320466
Lie, Marie Udnesseter; Matre, Dagfinn; Hansson, Per; Stubhaug, Audun; Zwart, John-Anker; Nilsen, Kristian Bernhard
2017-01-01
Abstract Introduction: The interest in conditioned pain modulation (CPM) as a clinical tool for measuring endogenously induced analgesia is increasing. There is, however, large variation in the CPM methodology, hindering comparison of results across studies. Research comparing different CPM protocols is needed in order to obtain a standardized test paradigm. Objectives: The aim of the study was to assess whether a protocol with phasic heat stimuli as test-stimulus is preferable to a protocol with tonic heat stimulus as test-stimulus. Methods: In this experimental crossover study, we compared 2 CPM protocols with different test-stimulus; one with tonic test-stimulus (constant heat stimulus of 120-second duration) and one with phasic test-stimuli (3 heat stimulations of 5 seconds duration separated by 10 seconds). Conditioning stimulus was a 7°C water bath in parallel with the test-stimulus. Twenty-four healthy volunteers were assessed on 2 occasions with minimum 1 week apart. Differences in the magnitude and test–retest reliability of the CPM effect in the 2 protocols were investigated with repeated-measures analysis of variance and by relative and absolute reliability indices. Results: The protocol with tonic test-stimulus induced a significantly larger CPM effect compared to the protocol with phasic test-stimuli (P < 0.001). Fair and good relative reliability was found with the phasic and tonic test-stimuli, respectively. Absolute reliability indices showed large intraindividual variability from session to session in both protocols. Conclusion: The present study shows that a CPM protocol with a tonic test-stimulus is preferable to a protocol with phasic test-stimuli. However, we emphasize that one should be cautious to use the CPM effect as biomarker or in clinical decision making on an individual level due to large intraindividual variability. PMID:29392240
Asher, Elad; Reuveni, Haim; Shlomo, Nir; Gerber, Yariv; Beigel, Roy; Narodetski, Michael; Eldar, Michael; Or, Jacob; Hod, Hanoch; Shamiss, Arie; Matetzky, Shlomi
2015-01-01
The aim of this study was to compare in patients presenting with acute chest pain the clinical outcomes and cost-effectiveness of an accelerated diagnostic protocol utilizing contemporary technology in a chest pain unit versus routine care in an internal medicine department. Hospital and 90-day course were prospectively studied in 585 consecutive low-moderate risk acute chest pain patients, of whom 304 were investigated in a designated chest pain center using a pre-specified accelerated diagnostic protocol, while 281 underwent routine care in an internal medicine ward. Hospitalization was longer in the routine care compared with the accelerated diagnostic protocol group (p<0.001). During hospitalization, 298 accelerated diagnostic protocol patients (98%) vs. 57 (20%) routine care patients underwent non-invasive testing, (p<0.001). Throughout the 90-day follow-up, diagnostic imaging testing was performed in 125 (44%) and 26 (9%) patients in the routine care and accelerated diagnostic protocol patients, respectively (p<0.001). Ultimately, most patients in both groups had non-invasive imaging testing. Accelerated diagnostic protocol patients compared with those receiving routine care was associated with a lower incidence of readmissions for chest pain [8 (3%) vs. 24 (9%), p<0.01], and acute coronary syndromes [1 (0.3%) vs. 9 (3.2%), p<0.01], during the follow-up period. The accelerated diagnostic protocol remained a predictor of lower acute coronary syndromes and readmissions after propensity score analysis [OR = 0.28 (CI 95% 0.14-0.59)]. Cost per patient was similar in both groups [($2510 vs. $2703 for the accelerated diagnostic protocol and routine care group, respectively, (p = 0.9)]. An accelerated diagnostic protocol is clinically superior and as cost effective as routine in acute chest pain patients, and may save time and resources.
Asher, Elad; Reuveni, Haim; Shlomo, Nir; Gerber, Yariv; Beigel, Roy; Narodetski, Michael; Eldar, Michael; Or, Jacob; Hod, Hanoch; Shamiss, Arie; Matetzky, Shlomi
2015-01-01
Aims The aim of this study was to compare in patients presenting with acute chest pain the clinical outcomes and cost-effectiveness of an accelerated diagnostic protocol utilizing contemporary technology in a chest pain unit versus routine care in an internal medicine department. Methods and Results Hospital and 90-day course were prospectively studied in 585 consecutive low-moderate risk acute chest pain patients, of whom 304 were investigated in a designated chest pain center using a pre-specified accelerated diagnostic protocol, while 281 underwent routine care in an internal medicine ward. Hospitalization was longer in the routine care compared with the accelerated diagnostic protocol group (p<0.001). During hospitalization, 298 accelerated diagnostic protocol patients (98%) vs. 57 (20%) routine care patients underwent non-invasive testing, (p<0.001). Throughout the 90-day follow-up, diagnostic imaging testing was performed in 125 (44%) and 26 (9%) patients in the routine care and accelerated diagnostic protocol patients, respectively (p<0.001). Ultimately, most patients in both groups had non-invasive imaging testing. Accelerated diagnostic protocol patients compared with those receiving routine care was associated with a lower incidence of readmissions for chest pain [8 (3%) vs. 24 (9%), p<0.01], and acute coronary syndromes [1 (0.3%) vs. 9 (3.2%), p<0.01], during the follow-up period. The accelerated diagnostic protocol remained a predictor of lower acute coronary syndromes and readmissions after propensity score analysis [OR = 0.28 (CI 95% 0.14–0.59)]. Cost per patient was similar in both groups [($2510 vs. $2703 for the accelerated diagnostic protocol and routine care group, respectively, (p = 0.9)]. Conclusion An accelerated diagnostic protocol is clinically superior and as cost effective as routine in acute chest pain patients, and may save time and resources. PMID:25622029
Prevention and treatment of hand oedema after stroke.
Kuppens, Stefanie P M; Pijlman, Hanneke C P; Hitters, Minou W M G C; van Heugten, Caroline M
2014-01-01
As there is no evidence for a specific treatment for post-stroke-induced hand oedema, rehabilitation centre Blixembosch formalized a best practice protocol. We investigated whether the Blixembosch hand oedema protocol is usable in daily practice and leads to lower incidence (prevention) and shorter duration (treatment) compared with care as usual. In a non-randomised comparative trial, we investigated 206 post-stroke patients admitted to two Dutch rehabilitation centres. Hand volumes were measured at least bi-weekly using a volumeter. Treatment was started according the protocol (Blixembosch) or following care as usual (Leijpark). Usability was assessed with a survey among professionals. In the Blixembosch group, 16% developed oedema after admission, compared with 21% in the control group (p = 0.019). Average duration of oedema (both developed before and after admission) was 6.5 weeks in the Blixembosch group compared with 3.1 weeks in the control group (p = 0.000). Professionals were positive about the protocol. The study showed that the protocol is usable in daily practice and has a small beneficial effect on hand oedema incidence rates compared with care as usual. The negative effect on duration of hand oedema could also be caused by the difference in prognosis between the two groups.
Developing and Implementing Protocols for Arctic Sea Ice Observations
NASA Astrophysics Data System (ADS)
Perovich, Donald K.; Gerland, Sebastian
2009-05-01
Arctic Surface-Based Sea Ice Observations: Integrated Protocols and Coordinated Data Acquisition; Tromsø, Norway, 26-27 January 2009; The Arctic sea ice cover is diminishing. Over the past several years, not only has ice thinned but the extent of ice at the end of summer, and hence perennial ice, has declined markedly. These changes affect a wide range of issues and are important for a varied group of stakeholders, including Arctic coastal communities, policy makers, industry, the scientific community, and the public. Concerns range from the role of sea ice cover as an indicator and amplifier of climate change to marine transportation, resource extraction, and coastal erosion. To understand and respond to these ongoing changes, it is imperative to develop and implement consistent and robust observational protocols that can be used to describe the current state of the ice cover as well as future changes.
Lighting Automation - Flying an Earthlike Habit Project
NASA Technical Reports Server (NTRS)
Falker, Jay; Howard, Ricky; Culbert, Christopher; Clark, Toni Anne; Kolomenski, Andrei
2017-01-01
Our proposal will enable the development of automated spacecraft habitats for long duration missions. Majority of spacecraft lighting systems employ lamps or zone specific switches and dimmers. Automation is not in the "picture". If we are to build long duration environments, which provide earth-like habitats, minimize crew time, and optimize spacecraft power reserves, innovation in lighting automation is a must. To transform how spacecraft lighting environments are automated, we will provide performance data on a standard lighting communication protocol. We will investigate utilization and application of an industry accepted lighting control protocol, DMX512. We will demonstrate how lighting automation can conserve power, assist with lighting countermeasures, and utilize spatial body tracking. By using DMX512 we will prove the "wheel" does not need to be reinvented in terms of smart lighting and future spacecraft can use a standard lighting protocol to produce an effective, optimized and potentially earthlike habitat.
Flexray - An Answer to the Challenges Faced by Spacecraft On-Board Communication Protocols
NASA Astrophysics Data System (ADS)
Gunes-Lasnet, S.; Furano, G.
2007-08-01
The current spacecraft on-board network protocols are facing challenges: They need to consume low power, to handle a high data rate, and eventually need to have real-time capabilities as well as fault-tolerance; all of this at a low cost. Meanwhile, the automotive protocols are showing ever increasing enhanced performances: the automotive industry has shown recent break-throughs in communication networks. Among them, FlexRay targets specifically the next generation of automotive applications allowing Steer-by-Wire and Brake-by- Wire. FlexRay supports a very high data rate, is fault- tolerant, has real-time capabilities, and supports both periodic and aperiodic data transfer on a single bus. Space avionics has benefited from the automotive spin- ins in the past, so could FlexRay answer the space systems demands? This paper aims at demonstrating that space avionics could profit from the use of FlexRay.
Toward Green Acylation of (Hetero)arenes: Palladium-Catalyzed Carbonylation of Olefins to Ketones
2017-01-01
Green Friedel–Crafts acylation reactions belong to the most desired transformations in organic chemistry. The resulting ketones constitute important intermediates, building blocks, and functional molecules in organic synthesis as well as for the chemical industry. Over the past 60 years, advances in this topic have focused on how to make this reaction more economically and environmentally friendly by using green acylating conditions, such as stoichiometric acylations and catalytic homogeneous and heterogeneous acylations. However, currently well-established methodologies for their synthesis either produce significant amounts of waste or proceed under harsh conditions, limiting applications. Here, we present a new protocol for the straightforward and selective introduction of acyl groups into (hetero)arenes without directing groups by using available olefins with inexpensive CO. In the presence of commercial palladium catalysts, inter- and intramolecular carbonylative C–H functionalizations take place with good regio- and chemoselectivity. Compared to classical Friedel–Crafts chemistry, this novel methodology proceeds under mild reaction conditions. The general applicability of this methodology is demonstrated by the direct carbonylation of industrial feedstocks (ethylene and diisobutene) as well as of natural products (eugenol and safrole). Furthermore, synthetic applications to drug molecules are showcased. PMID:29392174
Design optimization of a brush turbine with a cleaner/water based solution
NASA Technical Reports Server (NTRS)
Kim, Rhyn H.
1994-01-01
Recently, a fluid turbine which has a brush attached to it has been designed and tested with water as fluid. The purpose of the turbine-brush is to clean up fouling in a tube. The Montreal Protocol prohibits the use of CFC products from refrigeration industry or from industry in general as a cleanser in 1996. Alternatives for the cleansers, devices or a combination of alternative devices with a cleanser should be found. One of the methods is to develop a device which cleans fouling with a cleaning medium. In this paper, we describe a turbine connected with a brush. However, the turbine with the brush should be simple and easy to install. This device is a combined small liquid turbine with a brush. The turbine is activated by the liquid flowing through the tube. Then the turbine turns the brush cleaning fouling along the tube. Based on the energy conservation and the Bernoulli equation along with an empirical relationship of drag force obtained from an experimental apparatus, a relationship of the rotational speed, the number of blades, and geometric variables of the turbine-brush was obtained. The predicted rotational speeds were compared with the experimental observations. Further work was recommended for improvements.
DCBRP: a deterministic chain-based routing protocol for wireless sensor networks.
Marhoon, Haydar Abdulameer; Mahmuddin, M; Nor, Shahrudin Awang
2016-01-01
Wireless sensor networks (WSNs) are a promising area for both researchers and industry because of their various applications The sensor node expends the majority of its energy on communication with other nodes. Therefore, the routing protocol plays an important role in delivering network data while minimizing energy consumption as much as possible. The chain-based routing approach is superior to other approaches. However, chain-based routing protocols still expend substantial energy in the Chain Head (CH) node. In addition, these protocols also have the bottleneck issues. A novel routing protocol which is Deterministic Chain-Based Routing Protocol (DCBRP). DCBRP consists of three mechanisms: Backbone Construction Mechanism, Chain Head Selection (CHS), and the Next Hop Connection Mechanism. The CHS mechanism is presented in detail, and it is evaluated through comparison with the CCM and TSCP using an ns-3 simulator. It show that DCBRP outperforms both CCM and TSCP in terms of end-to-end delay by 19.3 and 65%, respectively, CH energy consumption by 18.3 and 23.0%, respectively, overall energy consumption by 23.7 and 31.4%, respectively, network lifetime by 22 and 38%, respectively, and the energy*delay metric by 44.85 and 77.54%, respectively. DCBRP can be used in any deterministic node deployment applications, such as smart cities or smart agriculture, to reduce energy depletion and prolong the lifetimes of WSNs.
Fleischmann, Ulrike; Pietsch, Hubertus; Korporaal, Johannes G; Flohr, Thomas G; Uder, Michael; Jost, Gregor; Lell, Michael M
2018-05-01
Low peak kilovoltage (kVp) protocols in computed tomography angiography (CTA) demand a review of contrast media (CM) administration practices. The aim of this study was to systematically evaluate different iodine concentrations of CM in a porcine model. Dynamic 70 kVp CTA was performed on 7 pigs using a third-generation dual-source CT system. Three CM injection protocols (A-C) with an identical total iodine dose and iodine delivery rate (150 mg I/kg, 12 s, 0.75 g I/s) differed in iodine concentration and flow rate (protocol A: 400 mg I/mL, 1.9 mL/s; B: 300 mg I/mL, 2.5 mL/s; C: 150 mg I/mL, 5 mL/s). All protocols were applied in a randomized order and compared intraindividually. Arterial enhancement at different locations in the pulmonary artery, the aorta, and aortic branches was measured over time. Time attenuation curves, peak enhancement, time to peak, and bolus tracking delay times needed for static CTA were calculated. The reproducibility of optimal parameters was tested in single-phase CTA. The heart rates of the pigs were comparable for all protocols (P > 0.7). The injection pressure was significantly higher for protocol A (64 ± 5 psi) and protocol C (55 ± 3 psi) compared with protocol B (39 ± 2 psi) (P < 0.001). Average arterial peak enhancement in the dynamic scans was 359 ± 51 HU (protocol A), 382 ± 36 HU (B), and 382 ± 60 HU (C) (A compared with B and C: P < 0.01; B compared with C: P = 0.995). Time to peak enhancement decreased with increasing injection rate. The delay time for bolus tracking depended on the injection rate as well and was highest for protocol A (4.7 seconds) and lowest for protocol C (3.9 seconds) (P = 0.038). The peak enhancement values of the dynamic scans highly correlated with those of the single-phase CTA scans. In 70 kVp CTA, 300 mg I/mL iodine concentrations showed to be superior to high-concentration CM when keeping the iodine delivery rate constant. Besides, iodine concentrations as low as 150 mg I/mL can be administered without compromising vascular enhancement. This opens up new possibilities in CM administration.
NASA Technical Reports Server (NTRS)
Hou, Tan-Hung
2014-01-01
For the fabrication of resin matrix fiber reinforced composite laminates, a workable cure cycle (i.e., temperature and pressure profiles as a function of processing time) is needed and is critical for achieving void-free laminate consolidation. Design of such a cure cycle is not trivial, especially when dealing with reactive matrix resins. An empirical "trial and error" approach has been used as common practice in the composite industry. Such an approach is not only costly, but also ineffective at establishing the optimal processing conditions for a specific resin/fiber composite system. In this report, a rational "processing science" based approach is established, and a universal cure cycle design protocol is proposed. Following this protocol, a workable and optimal cure cycle can be readily and rationally designed for most reactive resin systems in a cost effective way. This design protocol has been validated through experimental studies of several reactive polyimide composites for a wide spectrum of usage that has been documented in the previous publications.
Serial Interface through Stream Protocol on EPICS Platform for Distributed Control and Monitoring
NASA Astrophysics Data System (ADS)
Das Gupta, Arnab; Srivastava, Amit K.; Sunil, S.; Khan, Ziauddin
2017-04-01
Remote operation of any equipment or device is implemented in distributed systems in order to control and proper monitoring of process values. For such remote operations, Experimental Physics and Industrial Control System (EPICS) is used as one of the important software tool for control and monitoring of a wide range of scientific parameters. A hardware interface is developed for implementation of EPICS software so that different equipment such as data converters, power supplies, pump controllers etc. could be remotely operated through stream protocol. EPICS base was setup on windows as well as Linux operating system for control and monitoring while EPICS modules such as asyn and stream device were used to interface the equipment with standard RS-232/RS-485 protocol. Stream Device protocol communicates with the serial line with an interface to asyn drivers. Graphical user interface and alarm handling were implemented with Motif Editor and Display Manager (MEDM) and Alarm Handler (ALH) command line channel access utility tools. This paper will describe the developed application which was tested with different equipment and devices serially interfaced to the PCs on a distributed network.
Saade, Charbel; El-Merhi, Fadi; El-Achkar, Bassam; Kerek, Racha; Vogl, Thomas J; Maroun, Gilbert Georges; Jamjoom, Lamia; Al-Mohiy, Hussain; Naffaa, Lena
Caudocranial scan direction and contrast injection timing based on measured patient vessel dynamics can significantly improve arterial and aneurysmal opacification and reduce both contrast and radiation dose in the assessment of thoracic aortic aneurysms (TAA) using helical thoracic computed tomography angiography (CTA). To investigate opacification of the thoracic aorta and TAA using a caudocranial scan direction and a patient-specific contrast protocol. Thoracic aortic CTA was performed in 160 consecutive patients with suspected TAA using a 256-slice computed tomography scanner and a dual barrel contrast injector. Patients were subjected in equal numbers to one of two contrast protocols. Patient age and sex were equally distributed across both groups. Protocol A, the department's standard protocol, consisted of a craniocaudal scan direction with 100 mL of contrast, intravenously injected at a flow rate of 4.5 mL/s. Protocol B involved a caudocranial scan direction and a novel contrast formula based on patient cardiovascular dynamics, followed by 100 mL of saline at 4.5 mL/s. Each scan acquisition comprised of 120 kVp, 200 mA with modulation, temporal resolution 0.27 seconds, and pitch 0.889:1. The dose length product was measured between each protocol and data generated were compared using Mann-Whitney U nonparametric statistics. Receiver operating characteristic analysis, visual grading characteristic (VGC), and κ analyses were performed. Mean opacification in the thoracic aorta and aneurysm measured was 24 % and 55%, respectively. The mean contrast volume was significantly lower in protocol B (73 ± 10 mL) compared with A (100 ± 1 mL) (P<0.001). The contrast-to-noise ratio demonstrated significant differences between the protocols (protocol A, 18.2 ± 12.9; protocol B, 29.7 ± 0.61; P < 0.003). Mean effective dose in protocol B (2.6 ± 0.4 mSv) was reduced by 19% compared with A (3.2 ± 0.8 mSv) (P < 0.004). Aneurysmal detectability demonstrated significant increases by receiver operating characteristic and visual grading characteristic analysis for protocol B compared with A (P < 0.02), and reader agreement increased from poor to excellent. Significant increase in the visualization of TAAs following a caudocranial scan direction during helical thoracic CTA can be achieved using low-contrast volume based on patient-specific contrast formula.
Marienau, Karen J; Cramer, Elaine H; Coleman, Margaret S; Marano, Nina; Cetron, Martin S
2014-01-01
In-flight transmission risk of Mycobacterium tuberculosis is not well defined, although studies suggest it is low. The impact of flight-related tuberculosis (TB) contact investigations (TBCIs) on TB prevention and control is not well established, and they compete for resources with activities with established benefits. We sought to determine the risks and cost-benefits of using more restrictive criteria in comparison to the Centers for Disease Control and Prevention (CDC) 2008 protocol for TBCIs. The risk-benefits of a modified CDC protocol were analyzed in comparison to the 2008 CDC protocol using data from flight-related TBCIs conducted in the United States from 2007 through 2009. We predicted the numbers and characteristics of case-travelers that would be identified using each protocol's criteria, and results of the associated passenger-contacts' TB screening tests. The economic analysis compared the costs of TBCIs to avoided costs of TB treatment and mortality using a Return on Investment model. The estimated in-flight transmission risk using a modified CDC protocol was 1.4%-19% versus 1.1%-24% for the 2008 protocol. Numbers of TBCIs and immediate costs to health departments were reduced by half. Long-term cost-benefits were comparable. CDC's modified protocol appears to be a feasible alternative that will conserve public health resources without jeopardizing the public's health. Published by Elsevier Ltd.
Yilmaz, Vedat; Ince-Yilmaz, Ebru; Yilmazel, Yasemin Dilsad; Duran, Metin
2014-06-01
In this study, biomass samples were obtained from six municipal and nine industrial full-scale anaerobic processes to investigate whether the aceticlastic methanogen population composition is related to acetate utilization capacity and the nature of the wastewater treated, i.e. municipal sludge or industrial wastewater. Batch serum bottle tests were used to determine the specific acetate utilization rate (AUR), and a quantitative real-time polymerase chain reaction protocol was used to enumerate the acetate-utilizing Methanosaeta and Methanosarcina populations in the biomass samples. Methanosaeta was the dominant aceticlastic methanogen in all samples, except for one industrial wastewater-treating anaerobic process. However, Methanosarcina density in industrial biomass samples was higher than the Methanosarcina density in the municipal samples. The average AUR values of municipal and industrial wastewater treatment plant biomass samples were 10.49 and 10.65 mg CH3COO(-)/log(aceticlastic methanogen gene copy).d, respectively. One-way ANOVA test and principle component analysis showed that the acetate utilization capacities and aceticlastic methanogen community composition did not show statistically significant correlation among the municipal digesters and industrial wastewater-treating processes investigated.
Challenges and opportunities for growing blackberries in areas with adverse environmental conditions
USDA-ARS?s Scientific Manuscript database
The rotating cross-arm (RCA) technology (Fig. 1) combines a unique trellis design and cane training protocol. Developed over the last two decades, this technology is beginning to have an impact on the blackberry (Genus Rubus, subgenus Rubus) industry in the United States of America (USA). It has b...
Recommended Practices for the Safe Design and Operation of Flywheels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bender, Donald Arthur
2015-12-01
Flywheel energy storage systems are in use globally in increasing numbers . No codes pertaining specifically to flywheel energy storage exist. A number of industrial incidents have occurred. This protocol recommends a technical basis for safe flywheel de sign and operation for consideration by flywheel developers, users of flywheel systems and standards setting organizations.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-26
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0541... Request; Guidance for Industry on Special Protocol Assessment AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing that a proposed collection...
Developing a Model on Improving Maritime English Training for Maritime Transportation Safety
ERIC Educational Resources Information Center
Yercan, Funda; Fricke, Donna; Stone, Laurie
2005-01-01
Maritime services form an integral part of what regulatory agencies requires for the safe navigation and operation of vessels. Therefore, the maritime industry's compliance with governmental regulations and international protocols has been essential for maritime safety management. As a basis to this aspect, the preparation of maritime students as…
ERIC Educational Resources Information Center
Andrews, Dee H.; Dineen, Toni; Bell, Herbert H.
1999-01-01
Discusses the use of constructive modeling and virtual simulation in team training; describes a military application of constructive modeling, including technology issues and communication protocols; considers possible improvements; and discusses applications in team-learning environments other than military, including industry and education. (LRW)
Code of Federal Regulations, 2010 CFR
2010-01-01
... may be conducted, on a selective basis, to verify the absence of undeclared nuclear material and nuclear related activities at reportable uranium hard-rock mines and ore beneficiation plants (see § 783.1... OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS COMPLEMENTARY ACCESS...
Amides are an important class of compounds in the chemical and pharmaceutical industry1,2. Conventionally, amides have been synthesized by the hydration of nitriles, catalyzed by strong acids3 and bases4. Many by-products such as carboxylic acids are produced due to hydrolysis of...
The assumptions of traditional sampling theory often do not fit the circumstances when estimating the quantity and composition of solid waste arriving at a given location, such as a landfill site, or at a specific point in an industrial or commercial process. The investigator oft...
Modern strategy for operational excellence: building agile and adaptive organizations.
Gerwitz, Raymond J
2016-10-01
Healthcare security leaders who serve in an industry built on traditional and static protection and response protocols must become more agile and adaptive in planning and responding to evolving threat and risk profiles, the author states. In this article, he tells how to use operational excellence to continuously improve performance.
15 CFR 785.7 - Summary decision.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Summary decision. 785.7 Section 785.7... INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.7 Summary decision. The ALJ may render a summary decision disposing of all or part of a proceeding on the motion of...
2013-01-01
Background Lepidium campestre is an undomesticated oilseed species with a great potential to become a new crop for both food and industrial feedstocks production. Genetic modification is needed for further improving the oil quantity and quality of Lepidium. Studies on in vitro shoot regeneration of Lepidium are very limited and there is no transformation protocol available. Results We have investigated the effects of different factors, especially the type, concentration and combination of plant growth regulators (PGRs) on in vitro shoot regeneration of Lepidium. The results showed that the 2,4-D treatment was crucial to shoot regeneration from different explants. The duration of 2,4-D exposure between 2-4 days did not show significant difference in shoot regeneration, while the effect of 2,4-D concentration varied greatly depending on the type of explants and cytokinins used, for example, the low concentration of 2,4-D combined with TDZ significantly increased the regeneration frequency of hypocotyls. Cotyledon and hypocotyl explants responded differently to cytokinin, for example, TDZ was more effective than zeatin in promoting shoot regeneration from hypocotyls, but did not affect the regeneration of cotyledons which was more affected by high concentration of zeatin. The results also showed that NAA was not effective for shoot regeneration. Germination in light increased the regeneration frequency compared to that in dark. After optimization of the different conditions, an efficient regeneration protocol was developed with the regeneration efficiency of 92.7%. Using this protocol, the transformation frequency of 6% in average was achieved. The presence of transgenes in the transgenic lines was confirmed by GUS staining, PCR and Southern blot analyses. Conclusion Through systematic investigation of important factors affecting in vitro shoot regeneration, we have developed an efficient regeneration and transformation protocol for the genetic modification of Lepidium campestre. The method may also be applied to the related species. PMID:23937221
Readability of the Written Study Information in Pediatric Research in France
Ménoni, Véronique; Lucas, Noël; Leforestier, Jean-François; Doz, François; Chatellier, Gilles; Jacqz-Aigain, Evelyne; Giraud, Carole; Tréluyer, Jean-Marc; Chappuy, Hélène
2011-01-01
Background The aim was to evaluate the readability of research information leaflets (RIL) for minors asked to participate in biomedical research studies and to assess the factors influencing this readability. Methods and Findings All the pediatric protocols from three French pediatric clinical research units were included (N = 104). Three criteria were used to evaluate readability: length of the text, Flesch's readability score and presence of illustrations. We compared the readability of RIL to texts specifically written for children (school textbooks, school exams or extracts from literary works). We assessed the effect of protocol characteristics on readability. The RIL had a median length of 608 words [350 words, 25th percentile; 1005 words, 75th percentile], corresponding to two pages. The readability of the RIL, with a median Flesch score of 40 [30; 47], was much poorer than that of pediatric reference texts, with a Flesch score of 67 [60; 73]. A small proportion of RIL (13/91; 14%) were illustrated. The RIL were longer (p<0.001), more readable (p<0.001) and more likely to be illustrated (p<0.009) for industrial than for institutional sponsors. Conclusion Researchers should routinely compute the reading ease of study information sheets and make greater efforts to improve the readability of written documents for potential participants. PMID:21494689
Biocompatible hollow polymeric particles produced by a mild solvent- and template free strategy.
Rodríguez-Velázquez, Eustolia; Taboada, Pablo; Alatorre-Meda, Manuel
2017-08-31
Macroscopic hollow polymeric particles are attractive materials for various applications such as surgery, food industry, agriculture, etc. However, protocols reporting their synthesis have hitherto made use of organic solvents and/or sacrificial templates, compromising the encapsulation of different bioactive compounds and the process yield. Here, millimeter-size, hollow polymeric particles were synthesized, for the first time, in a solvent- and template free manner onto superhydrophobic surfaces (SHS). The particles were produced upon assembly and double superficial crosslinking of liquid droplets of DNA and methacrylamide chitosan aqueous solutions (CH:MA), leading to liquid-core particles with a hardened hydrogel shell. The particles displayed appealing physical and biological properties. The millimeter-size hydrogel shell, resulting from the double ionic/covalent crosslinking of CH:MA, endowed the hollow particles with softness to the touch and an outstanding structural stability against manipulation by hand and with forceps. Meanwhile, the liquid DNA core guaranteed a biocompatible cell encapsulation followed by a superior release and proliferation of viable cells, as compared to solid CH:MA particles prepared as a blank. Particles with these characteristics show promise for surgical protocols practiced in Tissue Engineering and Regenerative Medicine, where manipulable and biocompatible synthetic implants are often needed to supply living cells and other sensitive bioactive compounds. Copyright © 2017 Elsevier B.V. All rights reserved.
Biocompatible hollow polymeric particles produced by a mild solvent- and template free strategy.
Rodríguez-Velázquez, Eustolia; Taboada, Pablo; Alatorre-Meda, Manuel
2017-12-01
Macroscopic hollow polymeric particles are attractive materials for various applications such as surgery, food industry, agriculture, etc. However, protocols reporting their synthesis have hitherto made use of organic solvents and/or sacrificial templates, compromising the encapsulation of different bioactive compounds and the process yield. Here, millimeter-size, hollow polymeric particles were synthesized, for the first time, in a solvent- and template free manner onto superhydrophobic surfaces (SHS). The particles were produced upon assembly and double superficial crosslinking of liquid droplets of DNA and methacrylamide chitosan aqueous solutions (CH:MA), leading to liquid-core particles with a hardened hydrogel shell. The particles displayed appealing physical and biological properties. The millimeter-size hydrogel shell, resulting from the double ionic/covalent crosslinking of CH:MA, endowed the hollow particles with softness to the touch and an outstanding structural stability against manipulation by hand and with forceps. Meanwhile, the liquid DNA core guaranteed a biocompatible cell encapsulation followed by a superior release and proliferation of viable cells, as compared to solid CH:MA particles prepared as a blank. Particles with these characteristics show promise for surgical protocols practiced in Tissue Engineering and Regenerative Medicine, where manipulable and biocompatible synthetic implants are often needed to supply living cells and other sensitive bioactive compounds. Copyright © 2017. Published by Elsevier B.V.
Chen, Liyan; Vadlani, Praveen V; Madl, Ronald L
2014-01-15
Phytic acid of soy meal (SM) could influence protein and important mineral digestion of monogastric animals. Aspergillus oryzae (ATCC 9362) solid-state fermentation was applied to degrade phytic acid in SM. Two-stage temperature fermentation protocol was investigated to increase the degradation rate. The first stage was to maximize phytase production and the second stage was to realize the maximum enzymatic degradation. In the first stage, a combination of 41% moisture, a temperature of 37 °C and inoculum size of 1.7 mL in 5 g substrate (dry matter basis) favored maximum phytase production, yielding phytase activity of 58.7 U, optimized via central composite design. By the end of second-stage fermentation, 57% phytic acid was degraded from SM fermented at 50 °C, compared with 39% of that fermented at 37 °C. The nutritional profile of fermented SM was also studied. Oligosaccharides were totally removed after fermentation and 67% of total non-reducing polysaccharides were decreased. Protein content increased by 9.5%. Two-stage temperature protocol achieved better phytic acid degradation during A. oryzae solid state fermentation. The fermented SM has lower antinutritional factors (phytic acid, oligosaccharides and non-reducing polysaccharides) and higher nutritional value for animal feed. © 2013 Society of Chemical Industry.
Effects of a Short Drilling Implant Protocol on Osteotomy Site Temperature and Drill Torque.
Mihali, Sorin G; Canjau, Silvana; Cernescu, Anghel; Bortun, Cristina M; Wang, Hom-Lay; Bratu, Emanuel
2018-02-01
To establish a protocol for reducing the drilling sequence during implant site preparation based on temperature and insertion torque. The traditional conventional drilling sequence (used several drills with 0.6-mm increment each time) was compared with the proposed short drilling protocol (only used 2 drills: initial and final drill). One hundred drilling osteotomies were performed in bovine and porcine bones. Sets of 2 osteotomy sites were created in 5 bone densities using 2 types of drilling protocols. Thermographic pictures were captured throughout all drilling procedures and analyzed using ThermaCAM Researcher Professional 2.10. Torque values were determined during drilling by measuring electrical input and drill speed. There were statistically significant differences in bone temperature between the conventional and short drilling protocols during implant site preparation (analysis of variance P = 0.0008). However, there were no significant differences between the 2 types of drilling protocols for both implant diameters. Implant site preparation time was significantly reduced when using the short drilling protocol compared with the conventional drilling protocol (P < 0.001). Within the limitations of the study, the short drilling protocol proposed herein may represent a safe approach for implant site preparation.
Performance Improvement in Geographic Routing for Vehicular Ad Hoc Networks
Kaiwartya, Omprakash; Kumar, Sushil; Lobiyal, D. K.; Abdullah, Abdul Hanan; Hassan, Ahmed Nazar
2014-01-01
Geographic routing is one of the most investigated themes by researchers for reliable and efficient dissemination of information in Vehicular Ad Hoc Networks (VANETs). Recently, different Geographic Distance Routing (GEDIR) protocols have been suggested in the literature. These protocols focus on reducing the forwarding region towards destination to select the Next Hop Vehicles (NHV). Most of these protocols suffer from the problem of elevated one-hop link disconnection, high end-to-end delay and low throughput even at normal vehicle speed in high vehicle density environment. This paper proposes a Geographic Distance Routing protocol based on Segment vehicle, Link quality and Degree of connectivity (SLD-GEDIR). The protocol selects a reliable NHV using the criteria segment vehicles, one-hop link quality and degree of connectivity. The proposed protocol has been simulated in NS-2 and its performance has been compared with the state-of-the-art protocols: P-GEDIR, J-GEDIR and V-GEDIR. The empirical results clearly reveal that SLD-GEDIR has lower link disconnection and end-to-end delay, and higher throughput as compared to the state-of-the-art protocols. It should be noted that the performance of the proposed protocol is preserved irrespective of vehicle density and speed. PMID:25429415
Performance improvement in geographic routing for Vehicular Ad Hoc Networks.
Kaiwartya, Omprakash; Kumar, Sushil; Lobiyal, D K; Abdullah, Abdul Hanan; Hassan, Ahmed Nazar
2014-11-25
Geographic routing is one of the most investigated themes by researchers for reliable and efficient dissemination of information in Vehicular Ad Hoc Networks (VANETs). Recently, different Geographic Distance Routing (GEDIR) protocols have been suggested in the literature. These protocols focus on reducing the forwarding region towards destination to select the Next Hop Vehicles (NHV). Most of these protocols suffer from the problem of elevated one-hop link disconnection, high end-to-end delay and low throughput even at normal vehicle speed in high vehicle density environment. This paper proposes a Geographic Distance Routing protocol based on Segment vehicle, Link quality and Degree of connectivity (SLD-GEDIR). The protocol selects a reliable NHV using the criteria segment vehicles, one-hop link quality and degree of connectivity. The proposed protocol has been simulated in NS-2 and its performance has been compared with the state-of-the-art protocols: P-GEDIR, J-GEDIR and V-GEDIR. The empirical results clearly reveal that SLD-GEDIR has lower link disconnection and end-to-end delay, and higher throughput as compared to the state-of-the-art protocols. It should be noted that the performance of the proposed protocol is preserved irrespective of vehicle density and speed.
Comment on "flexible protocol for quantum private query based on B92 protocol"
NASA Astrophysics Data System (ADS)
Chang, Yan; Zhang, Shi-Bin; Zhu, Jing-Min
2017-03-01
In a recent paper (Quantum Inf Process 13:805-813, 2014), a flexible quantum private query (QPQ) protocol based on B92 protocol is presented. Here we point out that the B92-based QPQ protocol is insecure in database security when the channel has loss, that is, the user (Alice) will know more records in Bob's database compared with she has bought.
Aguiar, L. F.; Cunha, G. S. P.; Cardinot, N.; Lucena, E.
2014-01-01
The ovarian stimulation has been applied in order to increase the number of oocytes to compensate for the poor results of in vitro fertilization, allowing the selection of one or more embryos to be transferred. Our aim is to compare the results obtained in IVF/ICSI cycles using the short protocol for controlled ovarian stimulation to the results from the modified mild protocol used in our department. A total of 240 cycles were conducted from January 2010 to December 2011. When comparing both protocols, it could be observed that there was a significant difference in the quantity of gonadotropins doses in the mild protocol and in the short protocol. No significant difference was observed regarding pregnancy rates per cycle, 22% and 26.2%, in short and mild protocols, respectively. The protocols of controlled ovarian stimulation are often associated with high risk of complications such as ovarian hyperstimulation syndrome, excessive emotional stress, high rates of treatment dropouts, and abdominal discomfort. With the data obtained in this study, one can conclude that there are less risks and complications for the patient when using the mild stimulation protocol. It was also observed that in this group there was a slightly higher rate. PMID:25763398
Yoshida, Morikatsu; Utsunomiya, Daisuke; Kidoh, Masafumi; Yuki, Hideaki; Oda, Seitaro; Shiraishi, Shinya; Yamamoto, Hidekazu; Inomata, Yukihiro; Yamashita, Yasuyuki
2017-06-01
We evaluated whether donor computed tomography (CT) with a combined technique of lower tube voltage and iterative reconstruction (IR) can provide sufficient preoperative information for liver transplantation.We retrospectively reviewed CT of 113 liver donor candidates. Dynamic contrast-enhanced CT of the liver was performed on the following protocol: protocol A (n = 70), 120-kVp with filtered back projection (FBP); protocol B (n = 43), 100-kVp with IR. To equalize the background covariates, one-to-one propensity-matched analysis was used. We visually compared the score of the hepatic artery (A-score), portal vein (P-score), and hepatic vein (V-score) of the 2 protocols and quantitatively correlated the graft volume obtained by CT volumetry (graft-CTv) under the 2 protocols with the actual graft weight.In total, 39 protocol-A and protocol-B candidates showed comparable preoperative clinical characteristics with propensity matching. For protocols A and B, the A-score was 3.87 ± 0.73 and 4.51 ± 0.56 (P < .01), the P-score was 4.92 ± 0.27 and 5.0 ± 0.0 (P = .07), and the V-score was 4.23 ± 0.78 and 4.82 ± 0.39 (P < .01), respectively. Correlations between the actual graft weight and graft-CTv of protocols A and B were 0.97 and 0.96, respectively.Liver-donor CT imaging under 100-kVp plus IR protocol provides better visualization for vascular structures than that under 120-kVp plus FBP protocol with comparable accuracy for graft-CTv, while lowering radiation exposure by more than 40% and reducing contrast-medium dose by 20%.
Carpinella, Ilaria; Cattaneo, Davide; Bertoni, Rita; Ferrarin, Maurizio
2012-05-01
In this pilot study, we compared two protocols for robot-based rehabilitation of upper limb in multiple sclerosis (MS): a protocol involving reaching tasks (RT) requiring arm transport only and a protocol requiring both objects' reaching and manipulation (RMT). Twenty-two MS subjects were assigned to RT or RMT group. Both protocols consisted of eight sessions. During RT training, subjects moved the handle of a planar robotic manipulandum toward circular targets displayed on a screen. RMT protocol required patients to reach and manipulate real objects, by moving the robotic arm equipped with a handle which left the hand free for distal tasks. In both trainings, the robot generated resistive and perturbing forces. Subjects were evaluated with clinical and instrumental tests. The results confirmed that MS patients maintained the ability to adapt to the robot-generated forces and that the rate of motor learning increased across sessions. Robot-therapy significantly reduced arm tremor and improved arm kinematics and functional ability. Compared to RT, RMT protocol induced a significantly larger improvement in movements involving grasp (improvement in Grasp ARAT sub-score: RMT 77.4%, RT 29.5%, p=0.035) but not precision grip. Future studies are needed to evaluate if longer trainings and the use of robotic handles would significantly improve also fine manipulation.
Coleman, Margaret S; Marienau, Karen J; Marano, Nina; Marks, Suzanne M; Cetron, Martin S
2014-01-01
In 2011, the Centers for Disease Control and Prevention modified its 2008 protocol for flight-related tuberculosis contact investigation initiation. The 2011 Modified protocol was implemented and replaced the 2008 CDC protocol based on comparative epidemiologic and economic analyses; this publication reports the economic analysis results. A return on investment model compared relative changes in tuberculosis disease treatment costs resulting from expenditures on tuberculosis contact investigations and latent tuberculosis infection treatment for the 2008 CDC and Modified protocols. At moderate/high rates of latent tuberculosis infection and tuberculosis disease, positive returns on investment indicated each $1.00 spent on tuberculosis contact investigations and latent tuberculosis treatment resulted in more than $1.00 of savings from reduced tuberculosis disease treatment costs. Low rates of latent tuberculosis infection and tuberculosis disease resulted in negative returns on investment, indicating economic losses from tuberculosis disease treatment costs. There were smaller economic losses at low latent tuberculosis infection and tuberculosis disease rates with the Modified protocol in comparison to the 2008 CDC protocol, while both identified comparable numbers of persons at risk for tuberculosis. The Modified protocol for conducting flight-related tuberculosis contact investigations represents a better use of resources and protects public health. Published by Elsevier Ltd.
Coleman, Margaret S.; Marienau, Karen J.; Marano, Nina; Marks, Suzanne M.; Cetron, Martin S.
2017-01-01
Summary Background In 2011, the Centers for Disease Control and Prevention modified its 2008 protocol for flight-related tuberculosis contact investigation initiation. The 2011 Modified protocol was implemented and replaced the 2008 CDC protocol based on comparative epidemiologic and economic analyses; this publication reports the economic analysis results. Methods A return on investment model compared relative changes in tuberculosis disease treatment costs resulting from expenditures on tuberculosis contact investigations and latent tuberculosis infection treatment for the 2008 CDC and Modified protocols. Results At moderate/high rates of latent tuberculosis infection and tuberculosis disease, positive returns on investment indicated each $1.00 spent on tuberculosis contact investigations and latent tuberculosis treatment resulted in more than $1.00 of savings from reduced tuberculosis disease treatment costs. Low rates of latent tuberculosis infection and tuberculosis disease resulted in negative returns on investment, indicating economic losses from tuberculosis disease treatment costs. There were smaller economic losses at low latent tuberculosis infection and tuberculosis disease rates with the Modified protocol in comparison to the 2008 CDC protocol, while both identified comparable numbers of persons at risk for tuberculosis. Conclusion The Modified protocol for conducting flight-related tuberculosis contact investigations represents a better use of resources and protects public health. PMID:24262643
Economic burden and cost-effective management of Clostridium difficile infections.
Heimann, S M; Cruz Aguilar, M R; Mellinghof, S; Vehreschild, M J G T
2018-02-01
Clostridium difficile infection (CDI) is the most important cause of healthcare-associated infectious diarrhea in industrialized countries. We performed a literature review of the overall economic burden of initial and recurrent CDI as well as of the cost-effectiveness of the various treatment strategies applied in these settings. Even though analysis of health economic data is complicated by the limited comparability of results, our review identified several internationally consistent results. Authors from different countries have shown that recurrent CDI disproportionally contributes to the overall economic burden of CDI and therefore offers considerable saving potential. Subsequent cost-effectiveness analyses almost exclusively identified fidaxomicin as the preferred treatment option for initial CDI and fecal microbiota transplant (FMT) for recurrent CDI. Among the various FMT protocols, optimum results were obtained using early colonoscopy-based FMT. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Extracellular Microbial Metabolomics: The State of the Art
Villas-Boas, Silas G.
2017-01-01
Microorganisms produce and secrete many primary and secondary metabolites to the surrounding environment during their growth. Therefore, extracellular metabolites provide important information about the changes in microbial metabolism due to different environmental cues. The determination of these metabolites is also comparatively easier than the extraction and analysis of intracellular metabolites as there is no need for cell rupture. Many analytical methods are already available and have been used for the analysis of extracellular metabolites from microorganisms over the last two decades. Here, we review the applications and benefits of extracellular metabolite analysis. We also discuss different sample preparation protocols available in the literature for both types (e.g., metabolites in solution and in gas) of extracellular microbial metabolites. Lastly, we evaluate the authenticity of using extracellular metabolomics data in the metabolic modelling of different industrially important microorganisms. PMID:28829385
Extracellular Microbial Metabolomics: The State of the Art.
Pinu, Farhana R; Villas-Boas, Silas G
2017-08-22
Microorganisms produce and secrete many primary and secondary metabolites to the surrounding environment during their growth. Therefore, extracellular metabolites provide important information about the changes in microbial metabolism due to different environmental cues. The determination of these metabolites is also comparatively easier than the extraction and analysis of intracellular metabolites as there is no need for cell rupture. Many analytical methods are already available and have been used for the analysis of extracellular metabolites from microorganisms over the last two decades. Here, we review the applications and benefits of extracellular metabolite analysis. We also discuss different sample preparation protocols available in the literature for both types (e.g., metabolites in solution and in gas) of extracellular microbial metabolites. Lastly, we evaluate the authenticity of using extracellular metabolomics data in the metabolic modelling of different industrially important microorganisms.
Santos-Sanches, Ilda; Chambel, Lélia; Tenreiro, Rogério
2015-01-01
Pulsed-field gel electrophoresis (PFGE) separates large DNA molecules by the use of an alternating electrical field, such that greater size resolution can be obtained when compared to normal agarose gel electrophoresis. PFGE is often employed to track pathogens and is a valuable typing scheme to detect and differentiate strains. Particularly, the contour-clamped homogeneous electric field (CHEF) PFGE system is considered to be the gold standard for use in epidemiological studies of many bacterial pathogens. Here we describe a PFGE protocol that was applicable to the study of bovine streptococci, namely, Streptococcus agalactiae (group B Streptococcus, GBS), Streptococcus dysgalactiae subsp. dysgalactiae (group C Streptococcus, GCS), and Streptococcus uberis-which are relevant pathogens causing mastitis, a highly prevalent and costly disease in dairy industry due to antibiotherapy and loss in milk production.
Vignion-Dewalle, Anne-Sophie; Baert, Gregory; Devos, Laura; Thecua, Elise; Vicentini, Claire; Mortier, Laurent; Mordon, Serge
2017-09-01
Photodynamic therapy (PDT) is an emerging treatment modality for various diseases, especially for dermatological conditions. Although, the standard PDT protocol for the treatment of actinic keratoses in Europe has shown to be effective, treatment-associated pain is often observed in patients. Different modifications to this protocol attempted to decrease pain have been investigated. The decrease in fluence rate seems to be a promising solution. Moreover, it has been suggested that light fractionation significantly increases the efficacy of PDT. Based on a flexible light-emitting textile, the FLEXITHERALIGHT device specifically provides a fractionated illumination at a fluence rate more than six times lower than that of the standard protocol. In a recently completed clinical trial of PDT for the treatment of actinic keratosis, the non-inferiority of a protocol involving illumination with the FLEXITHERALIGHT device after a short incubation time and referred to as the FLEXITHERALIGHT protocol has been assessed compared to the standard protocol. In this paper, we propose a comparison of the two above mentioned 635 nm red light protocols with 37 J/cm 2 in the PDT treatment of actinic keratosis: the standard protocol and the FLEXITHERALIGHT one through a mathematical modeling. This mathematical modeling, which slightly differs from the one we have already published, enables the local damage induced by the therapy to be estimated. The comparison performed in terms of the local damage induced by the therapy demonstrates that the FLEXITHERALIGHT protocol with lower fluence rate, light fractionation and shorter incubation time is somewhat less efficient than the standard protocol. Nevertheless, from the clinical trial results, the FLEXITHERALIGHT protocol results in non-inferior response rates compared to the standard protocol. This finding raises the question of whether the PDT local damage achieved by the FLEXITHERALIGHT protocol (respectively, the standard protocol) is sufficient (respectively, excessive) to destroy actinic keratosis cells. Lasers Surg. Med. 49:686-697, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Improvement of burn pain management through routine pain monitoring and pain management protocol.
Yang, Hyeong Tae; Hur, Giyeun; Kwak, In-Suk; Yim, Haejun; Cho, Yong Suk; Kim, Dohern; Hur, Jun; Kim, Jong Hyun; Lee, Boung Chul; Seo, Cheong Hoon; Chun, Wook
2013-06-01
Pain management is an important aspect of burn management. We developed a routine pain monitoring system and pain management protocol for burn patients. The purpose of this study is to evaluate the effectiveness of our new pain management system. From May 2011 to November 2011, the prospective study was performed with 107 burn patients. We performed control group (n=58) data analysis and then developed the pain management protocol and monitoring system. Next, we applied our protocol to patients and performed protocol group (n=49) data analysis, and compared this to control group data. Data analysis was performed using the Numeric Rating Scale (NRS) of background pain and procedural pain, Clinician-Administered PTSD Scale (CAPS), Hamilton Depression Rating Scale (HDRS), State-Trait Anxiety Inventory Scale (STAIS), and Holmes and Rahe Stress Scale (HRSS). The NRS of background pain for the protocol group was significantly decreased compared to the control group (2.8±2.0 versus 3.9±1.9), and the NRS of procedural pain of the protocol group was significantly decreased compared to the control group (4.8±2.8 versus 3.7±2.5). CAPS and HDRS were decreased in the protocol group, but did not have statistical significance. STAIS and HRSS were decreased in the protocol group, but only the STAIS had statistical significance. Our new pain management system was effective in burn pain management. However, adequate pain management can only be accomplished by a continuous and thorough effort. Therefore, pain control protocol and pain monitoring systems need to be under constant revision and improvement using creative ideas and approaches. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.
Abduo, Jaafar; Chen, Chen; Le Breton, Eugene; Radu, Alexandra; Szeto, Josephine; Judge, Roy; Darby, Ivan
To compare the Encode impression protocol (Biomet 3i) with the conventional impression protocol in terms of treatment duration, clinical accuracy, and outcome up to the first postplacement review of single-implant crowns. A total of 45 implants were included in this study. The implants were randomly allocated to the Encode group (23 implants) or the conventional group (22 implants). At the time of surgery, all implants received two-piece Encode healing abutments. The implants were restored 3 months after insertion. In the conventional protocol, open-tray implant-level impressions were taken and the implants were restored with prefabricated abutments and porcelain-fused-to-metal (PFM) crowns. For the implants in the Encode group, closed-tray impressions of the healing abutments were taken. The generated casts were sent to the Biomet 3i scanning/milling center for custom abutment manufacturing on which PFM crowns were fabricated. Treatment duration (laboratory and clinical), clinical accuracy of occlusal and proximal contacts, and outcome (esthetics, patient satisfaction, and crown contour) were evaluated with the aid of a series of questionnaires. The Encode protocol required significantly less laboratory time (18 minutes) than the conventional protocol for adjustment of the abutments. The impression pour time, time for the laboratory to return the crown, time for crown insertion at the final appointment, and total clinical time for crown insertion did not differ significantly between the two protocols. Likewise, clinical accuracy, esthetics, and patient satisfaction were similar for the two protocols. The two protocols were clinically comparable. The Encode protocol is advantageous in reducing the laboratory time before crown fabrication.
Atencia, Rebeca; Stöhr, Eric J; Drane, Aimee L; Stembridge, Mike; Howatson, Glyn; Del Rio, Pablo Rodriguez Lopez; Feltrer, Yedra; Tafon, Babila; Redrobe, Sharon; Peck, Bruce; Eng, Jaclyn; Unwin, Steve; Sanchez, Carlos R; Shave, Rob E
2017-09-01
Limited data are available on hemodynamic responses to anesthetic protocols in wild-born chimpanzees (Pan troglodytes). Accordingly, this study characterized the heart rate (HR) and blood pressure responses to four anesthetic protocols in 176 clinically healthy, wild-born chimpanzees undergoing routine health assessments. Animals were anesthetized with medetomidine-ketamine (MK) (n = 101), tiletamine-zolazepam (TZ) (n = 30), tiletamine-zolazepam-medetomidine (TZM) (n = 24), or medetomidine-ketamine (maintained with isoflurane) (MKI) (n = 21). During each procedure, HR, systolic blood pressure (SBP), and diastolic blood pressure (DBP) were regularly recorded. Data were grouped according to anesthetic protocol, and mean HR, SBP, and DBP were calculated. Differences between mean HR, SBP, and DBP for each anesthetic protocol were assessed using the Kruskall-Wallis test and a Dunn multiple comparisons post hoc analysis. To assess the hemodynamic time course response to each anesthetic protocol, group mean data (±95% confidence interval [CI]) were plotted against time postanesthetic induction. Mean HR (beats/min [CI]) was significantly higher in TZ (86 [80-92]) compared to MKI (69 [61-78]) and MK (62 [60-64]) and in TZM (73 [68-78]) compared to MK. The average SBP and DBP values (mm Hg [CI]) were significantly higher in MK (130 [126-134] and 94 [91-97]) compared to TZ (104 [96-112] and 58 [53-93]) and MKI (113 [103-123] and 78 [69-87]) and in TZM (128 [120-135] and 88 [83-93]) compared to TZ. Time course data were markedly different between protocols, with MKI showing the greatest decline over time. Both the anesthetic protocol adopted and the timing of measurement after injection influence hemodynamic recordings in wild-born chimpanzees and need to be considered when monitoring or assessing cardiovascular health.
Lopez-Rendon, Xochitl; Zhang, Guozhi; Coudyzer, Walter; Develter, Wim; Bosmans, Hilde; Zanca, Federica
2017-11-01
To compare the lung and breast dose associated with three chest protocols: standard, organ-based tube current modulation (OBTCM) and fast-speed scanning; and to estimate the error associated with organ dose when modelling the longitudinal (z-) TCM versus the 3D-TCM in Monte Carlo simulations (MC) for these three protocols. Five adult and three paediatric cadavers with different BMI were scanned. The CTDI vol of the OBTCM and the fast-speed protocols were matched to the patient-specific CTDI vol of the standard protocol. Lung and breast doses were estimated using MC with both z- and 3D-TCM simulated and compared between protocols. The fast-speed scanning protocol delivered the highest doses. A slight reduction for breast dose (up to 5.1%) was observed for two of the three female cadavers with the OBTCM in comparison to the standard. For both adult and paediatric, the implementation of the z-TCM data only for organ dose estimation resulted in 10.0% accuracy for the standard and fast-speed protocols, while relative dose differences were up to 15.3% for the OBTCM protocol. At identical CTDI vol values, the standard protocol delivered the lowest overall doses. Only for the OBTCM protocol is the 3D-TCM needed if an accurate (<10.0%) organ dosimetry is desired. • The z-TCM information is sufficient for accurate dosimetry for standard protocols. • The z-TCM information is sufficient for accurate dosimetry for fast-speed scanning protocols. • For organ-based TCM schemes, the 3D-TCM information is necessary for accurate dosimetry. • At identical CTDI vol , the fast-speed scanning protocol delivered the highest doses. • Lung dose was higher in XCare than standard protocol at identical CTDI vol .
A systematic review of postoperative hand therapy management of basal joint arthritis.
Wolfe, Terri; Chu, Jennifer Y; Woods, Tammy; Lubahn, John D
2014-04-01
There are a variety of postoperative immobilization and therapy options for patients with basal joint arthritis. Although prior systematic reviews have compared surgical procedures used to treat basal joint arthritis, none to our knowledge compares therapy protocols for this condition, which are considered an important part of the treatment. (1) We sought to determine whether differences in the length and type of postoperative immobilization affect clinical results after basal joint arthritis surgery. (2) We also compared specific therapy protocols that were prescribed. (3) Finally, we evaluated published protocols to determine when patients were released to full activity to see whether these appeared to affect clinical results. A systematic review of English-language studies in the PubMed and Cochrane databases was performed. Studies were then reviewed to determine what postoperative immobilization and therapy protocols the authors used and when patients were released to full activities. A total of 19 studies were identified using the search criteria. All but one of the studies included a postoperative period of immobilization in either a cast or splint. Immobilization time varied depending on whether Kirschner wires were used for the surgery and whether an implant was placed. Postoperative therapy protocols also varied but followed three general patterns. Some therapy protocols involved teaching patients a home exercise program only, whereas some authors described routine referral to a therapist. The third group consisted of studies in which patients were only referred for therapy if the physicians determined it was necessary during followup. Many studies did not give a specific time for full return to activity and instead described a gradual transition to full activity after immobilization was discontinued. Because of the variability and small numbers, no conclusive recommendations could be made on any of the three study questions. Comparative, multicenter studies comparing different immobilization and therapy protocols after the surgical treatment of basal joint arthritis would be helpful for both surgeons and therapists looking to refine their treatment protocols.
Measurement of fecal elastase improves performance of newborn screening for cystic fibrosis.
Barben, Juerg; Rueegg, Corina S; Jurca, Maja; Spalinger, Johannes; Kuehni, Claudia E
2016-05-01
The aim of newborn screening (NBS) for CF is to detect children with 'classic' CF where early treatment is possible and improves prognosis. Children with inconclusive CF diagnosis (CFSPID) should not be detected, as there is no evidence for improvement through early treatment. No algorithm in current NBS guidelines explains what to do when sweat test (ST) fails. This study compares the performance of three different algorithms for further diagnostic evaluations when first ST is unsuccessful, regarding the numbers of children detected with CF and CFSPID, and the time until a definite diagnosis. In Switzerland, CF-NBS was introduced in January 2011 using an IRT-DNA-IRT algorithm followed by a ST. In children, in whom ST was not possible (no or insufficient sweat), 3 different protocols were applied between 2011 and 2014: in 2011, ST was repeated until it was successful (protocol A), in 2012 we proceeded directly to diagnostic DNA testing (protocol B), and 2013-2014, fecal elastase (FE) was measured in the stool, in order to determine a pancreas insufficiency needing immediate treatment (protocol C). The ratio CF:CFSPID was 7:1 (27/4) with protocol A, 2:1 (22/10) with protocol B, and 14:1 (54/4) with protocol C. The mean time to definite diagnosis was significantly shorter with protocol C (33days) compared to protocol A or B (42 and 40days; p=0.014 compared to A, and p=0.036 compared to B). The algorithm for the diagnostic part of the newborn screening used in the CF centers is important and affects the performance of a CF-NBS program with regard to the ratio CF:CFSPID and the time until definite diagnosis. Our results suggest to include FE after initial sweat test failure in the CF-NBS guidelines to keep the proportion of CFSPID low and the time until definite diagnosis short. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Ferber, Reed; Bolgla, Lori; Earl-Boehm, Jennifer E.; Emery, Carolyn; Hamstra-Wright, Karrie
2015-01-01
Context: Patellofemoral pain (PFP) is the most common injury in running and jumping athletes. Randomized controlled trials suggest that incorporating hip and core strengthening (HIP) with knee-focused rehabilitation (KNEE) improves PFP outcomes. However, no randomized controlled trials have, to our knowledge, directly compared HIP and KNEE programs. Objective: To compare PFP pain, function, hip- and knee-muscle strength, and core endurance between KNEE and HIP protocols after 6 weeks of rehabilitation. We hypothesized greater improvements in (1) pain and function, (2) hip strength and core endurance for patients with PFP involved in the HIP protocol, and (3) knee strength for patients involved in the KNEE protocol. Design: Randomized controlled clinical trial. Setting: Four clinical research laboratories in Calgary, Alberta; Chicago, Illinois; Milwaukee, Wisconsin; and Augusta, Georgia. Patients or Other Participants: Of 721 patients with PFP screened, 199 (27.6%) met the inclusion criteria (66 men [31.2%], 133 women [66.8%], age = 29.0 ± 7.1 years, height = 170.4 ± 9.4 cm, weight = 67.6 ± 13.5 kg). Intervention(s): Patients with PFP were randomly assigned to a 6-week KNEE or HIP protocol. Main Outcome Measure(s): Primary variables were self-reported visual analog scale and Anterior Knee Pain Scale measures, which were conducted weekly. Secondary variables were muscle strength and core endurance measured at baseline and at 6 weeks. Results: Compared with baseline, both the visual analog scale and the Anterior Knee Pain Scale improved for patients with PFP in both the HIP and KNEE protocols (P < .001), but the visual analog scale scores for those in the HIP protocol were reduced 1 week earlier than in the KNEE group. Both groups increased in strength (P < .001), but those in the HIP protocol gained more in hip-abductor (P = .01) and -extensor (P = .01) strength and posterior core endurance (P = .05) compared with the KNEE group. Conclusions: Both the HIP and KNEE rehabilitation protocols produced improvements in PFP, function, and strength over 6 weeks. Although outcomes were similar, the HIP protocol resulted in earlier resolution of pain and greater overall gains in strength compared with the KNEE protocol. PMID:25365133
The Upper Midwest Health Study: industry and occupation of glioma cases and controls.
Ruder, Avima M; Waters, Martha A; Carreón, Tania; Butler, Mary A; Calvert, Geoffrey M; Davis-King, Karen E; Waters, Kathleen M; Schulte, Paul A; Mandel, Jack S; Morton, Roscoe F; Reding, Douglas J; Rosenman, Kenneth D
2012-09-01
Understanding glioma etiology requires determining which environmental factors are associated with glioma. Upper Midwest Health Study case-control participant work histories collected 1995-1998 were evaluated for occupational associations with glioma. "Exposures of interest" from our study protocol comprise our a priori hypotheses. Year-long or longer jobs for 1,973 participants were assigned Standard Occupational Classifications (SOC) and Standard Industrial Classifications (SIC). The analysis file includes 8,078 SIC- and SOC-coded jobs. For each individual, SAS 9.2 programs collated employment with identical SIC-SOC coding. Distributions of longest "total employment duration" (total years worked in jobs with identical industry and occupation codes, including multiple jobs, and non-consecutive jobs) were compared between cases and controls, using an industrial hygiene algorithm to group occupations. Longest employment duration was calculated for 780 cases and 1,156 controls. More case than control longest total employment duration was in the "engineer, architect" occupational group [16 cases, 10 controls, odds ratio (OR) 2.50, adjusted for age group, sex, age and education, 95% confidence interval (CI) 1.12-5.60]. Employment as a food processing worker [mostly butchers and meat cutters] was of borderline significance (27 cases, 21 controls, adjusted OR: 1.78, CI: 0.99-3.18). Among our exposures of interest work as engineers or as butchers and meat cutters was associated with increased glioma risk. Significant associations could be due to chance, because of multiple comparisons, but similar findings have been reported for other glioma studies. Our results suggest some possible associations but by themselves could not provide conclusive evidence. Copyright © 2012 Wiley Periodicals, Inc.
The Upper Midwest Health Study: Industry and Occupation of Glioma Cases and Controls
Ruder, Avima M.; Waters, Martha A.; Carreón, Tania; Butler, Mary A.; Calvert, Geoffrey M.; Davis-King, Karen E.; Waters, Kathleen M.; Schulte, Paul A.; Mandel, Jack S.; Morton, Roscoe F.; Reding, Douglas J.; Rosenman, Kenneth D.
2015-01-01
Background Understanding glioma etiology requires determining which environmental factors are associated with glioma. Upper Midwest Health Study case–control participant work histories collected 1995–1998 were evaluated for occupational associations with glioma. “Exposures of interest” from our study protocol comprise our a priori hypotheses. Materials and Methods Year-long or longer jobs for 1,973 participants were assigned Standard Occupational Classifications (SOC) and Standard Industrial Classifications (SIC). The analysis file includes 8,078 SIC- and SOC-coded jobs. For each individual, SAS 9.2 programs collated employment with identical SIC-SOC coding. Distributions of longest “total employment duration” (total years worked in jobs with identical industry and occupation codes, including multiple jobs, and non-consecutive jobs) were compared between cases and controls, using an industrial hygiene algorithm to group occupations. Results Longest employment duration was calculated for 780 cases and 1,156 controls. More case than control longest total employment duration was in the “engineer, architect” occupational group [16 cases, 10 controls, odds ratio (OR) 2.50, adjusted for age group, sex, age and education, 95% confidence interval (CI) 1.12–5.60]. Employment as a food processing worker [mostly butchers and meat cutters] was of borderline significance (27 cases, 21 controls, adjusted OR: 1.78, CI: 0.99–3.18). Conclusions Among our exposures of interest work as engineers or as butchers and meat cutters was associated with increased glioma risk. Significant associations could be due to chance, because of multiple comparisons, but similar findings have been reported for other glioma studies. Our results suggest some possible associations but by themselves could not provide conclusive evidence. PMID:22715102
Brunner, Dani; Balcı, Fuat; Ludvig, Elliot A
2012-02-01
Drug discovery for brain disorders is undergoing a period of upheaval. Faced with an empty drug pipeline and numerous failures of potential new drugs in clinical trials, many large pharmaceutical companies have been shrinking or even closing down their research divisions that focus on central nervous system (CNS) disorders. In this paper, we argue that many of the difficulties facing CNS drug discovery stem from a lack of robustness in pre-clinical (i.e., non-human animal) testing. There are two main sources for this lack of robustness. First, there is the lack of replicability of many results from the pre-clinical stage, which we argue is driven by a combination of publication bias and inappropriate selection of statistical and experimental designs. Second, there is the frequent failure to translate results in non-human animals to parallel results in humans in the clinic. This limitation can only be overcome by developing new behavioral tests for non-human animals that have predictive, construct, and etiological validity. Here, we present these translational difficulties as a "grand challenge" to researchers from comparative cognition, who are well positioned to provide new methods for testing behavior and cognition in non-human animals. These new experimental protocols will need to be both statistically robust and target behavioral and cognitive processes that allow for better connection with human CNS disorders. Our hope is that this downturn in industrial research may represent an opportunity to develop new protocols that will re-kindle the search for more effective and safer drugs for CNS disorders. Copyright © 2011 Elsevier B.V. All rights reserved.
Innovative approach to facilitate reuse of nonhazardous industrial solid waste as building material
DOE Office of Scientific and Technical Information (OSTI.GOV)
St-Laurent, S.G.; Boutin, A.
1997-12-31
The steel industry generates large volumes of inorganic nonhazardous solid waste. During the last five years, Quebec`s steel industry has developed new technologies to recover metal from slags and tailings. Since these processes recover 10 to 30 percent of the metal, large volumes of nonhazardous residues still need to be recycled or disposed of. In order to encourage recycling initiatives, le Ministere de l`Environnement et de la Faune du Quebec (MEF) (Quebec`s Ministry of Environment and Wildlife) established guidelines for the management of nonhazardous industrial solid waste. The aim of these guidelines is to propose a test procedure to evaluatemore » the quality of the material and to define material classes based on their potential for reuse. The evaluation procedure is based on standard tests, generally used for the evaluation of stabilized and solidified hazardous waste. The protocol includes an analysis of the total content of metals in the residue, the determination of the acid neutralization capacity and the prediction of the acid generation potential when the residue contains significant levels of sulfides. The protocol includes three different leachate tests in order to evaluate the mobility of contaminants present in the residue. The leaching procedures are: (1) an equilibrium extraction with water, (2) a modified TCLP extraction, and (3) an acid rain simulation effect extraction. A method is actually under development to collect leachate from a material pile subject to 18 months of rainfall. Materials are categorized into different classes according to their test results. Various potential reuse options are associated with material classes. Evaluation criteria were defined by using water quality standards and results obtained by testing reference construction material supplied by the Quebec`s Ministere des Transports (Ministry of Transportation).« less
Guidelines and sample protocol for sampling forest gaps.
J.R. Runkle
1992-01-01
A protocol for sampling forest canopy gaps is presented. Methods used in published gap studies are reviewed. The sample protocol will be useful in developing a broader understanding of forest structure and dynamics through comparative studies across different forest ecosystems.
A Novel Quantum Solution to Privacy-Preserving Nearest Neighbor Query in Location-Based Services
NASA Astrophysics Data System (ADS)
Luo, Zhen-yu; Shi, Run-hua; Xu, Min; Zhang, Shun
2018-04-01
We present a cheating-sensitive quantum protocol for Privacy-Preserving Nearest Neighbor Query based on Oblivious Quantum Key Distribution and Quantum Encryption. Compared with the classical related protocols, our proposed protocol has higher security, because the security of our protocol is based on basic physical principles of quantum mechanics, instead of difficulty assumptions. Especially, our protocol takes single photons as quantum resources and only needs to perform single-photon projective measurement. Therefore, it is feasible to implement this protocol with the present technologies.
Nonblocking and orphan free message logging protocols
NASA Technical Reports Server (NTRS)
Alvisi, Lorenzo; Hoppe, Bruce; Marzullo, Keith
1992-01-01
Currently existing message logging protocols demonstrate a classic pessimistic vs. optimistic tradeoff. We show that the optimistic-pessimistic tradeoff is not inherent to the problem of message logging. We construct a message-logging protocol that has the positive features of both optimistic and pessimistic protocol: our protocol prevents orphans and allows simple failure recovery; however, it requires no blocking in failure-free runs. Furthermore, this protocol does not introduce any additional message overhead as compared to one implemented for a system in which messages may be lost but processes do not crash.
Nonblocking and orphan free message logging protocols
NASA Astrophysics Data System (ADS)
Alvisi, Lorenzo; Hoppe, Bruce; Marzullo, Keith
1992-12-01
Currently existing message logging protocols demonstrate a classic pessimistic vs. optimistic tradeoff. We show that the optimistic-pessimistic tradeoff is not inherent to the problem of message logging. We construct a message-logging protocol that has the positive features of both optimistic and pessimistic protocol: our protocol prevents orphans and allows simple failure recovery; however, it requires no blocking in failure-free runs. Furthermore, this protocol does not introduce any additional message overhead as compared to one implemented for a system in which messages may be lost but processes do not crash.
A comparative study of routing protocols of heterogeneous wireless sensor networks.
Han, Guangjie; Jiang, Xu; Qian, Aihua; Rodrigues, Joel J P C; Cheng, Long
2014-01-01
Recently, heterogeneous wireless sensor network (HWSN) routing protocols have drawn more and more attention. Various HWSN routing protocols have been proposed to improve the performance of HWSNs. Among these protocols, hierarchical HWSN routing protocols can improve the performance of the network significantly. In this paper, we will evaluate three hierarchical HWSN protocols proposed recently--EDFCM, MCR, and EEPCA--together with two previous classical routing protocols--LEACH and SEP. We mainly focus on the round of the first node dies (also called the stable period) and the number of packets sent to sink, which is an important aspect to evaluate the monitoring ability of a protocol. We conduct a lot of experiments and simulations on Matlab to analyze the performance of the five routing protocols.
Failure of antiarrhythmic drugs to prevent experimental reperfusion ventricular fibrillation.
Naito, M; Michelson, E L; Kmetzo, J J; Kaplinsky, E; Dreifus, L S
1981-01-01
Ninety-nine adult mongrel dogs underwent acute ligation of the proximal left anterior descending coronary artery. Thirty minutes later, the occlusion was released to evaluate the effectiveness of five antiarrhythmic protocols in eliminating reperfusion ventricular fibrillation. The five protocols included: protocol 1 --i.v. lidocaine, preligation and prerelease (n = 19); protocol 2 -- i.v. lidocaine, prereperfusion only (n = 22); protocol 3 -- chronic, oral, daily amiodarone for 2 weeks preligation (n = 19); protocol 4 -- i.v. procainamide, preligation and prereperfusion (n = 21); and protocol 5 -- i.v. verapamil, prereperfusion (n = 18). Each regimen was evaluated with respect to the incidence of reperfusion ventricular fibrillation in dogs that survived to reperfusion, and the results were compared to 77 control dogs that underwent identical coronary artery occlusion and release procedures without drug therapy. The incidence of reperfusion ventricular fibrillation was as follows: protocol 1 -- seven of 15 dogs (47%); protocol 2 -- six of 18 (33%); protocol 3 -- 11 of 16 dogs (69%); protocol 4 -- eight of 17 dogs (47%); and protocol 5 -- 10 of 17 dogs (59%), compared with 36 of 60 (60%) in control dogs. Using chi-square analysis, protocol 2 was beneficial (p < 0.05). The dogs were then stratified into high- and low-risk subgroups based on the arrhythmic events of the antecedent coronary artery ligation periods, and predictive risk indexes for the occurrence of reperfusion ventricular fibrillation were developed. the Mantel-Haenszel method of statistical analysis revealed that none of these protocols resulted in a statistically significant reduction in the incidence of reperfusion ventricular fibrillation. Thus, use of these predictive indexes plus appropriate statistical methods has revealed, unexpectedly, limitations in the efficacy of a spectrum of antiarrhythmic agents in preventing reperfusion ventricular fibrillation.
Preparative Purification of Recombinant Proteins: Current Status and Future Trends
Saraswat, Mayank; Ravidá, Alessandra; Holthofer, Harry
2013-01-01
Advances in fermentation technologies have resulted in the production of increased yields of proteins of economic, biopharmaceutical, and medicinal importance. Consequently, there is an absolute requirement for the development of rapid, cost-effective methodologies which facilitate the purification of such products in the absence of contaminants, such as superfluous proteins and endotoxins. Here, we provide a comprehensive overview of a selection of key purification methodologies currently being applied in both academic and industrial settings and discuss how innovative and effective protocols such as aqueous two-phase partitioning, membrane chromatography, and high-performance tangential flow filtration may be applied independently of or in conjunction with more traditional protocols for downstream processing applications. PMID:24455685
Breaking Bad News in Healthcare Organizations: Application of the Spikes Protocol
ERIC Educational Resources Information Center
VonBergen, C. W.; Stevens, Robert E.; Loudon, David
2011-01-01
Organizational downsizing has increased exponentially worldwide and is also affecting the healthcare industry. It is one thing to speak abstractly of the need to reduce costs and quite another to actually tell a worker the bad news that he or she has been laid off. This paper offers practical advice to healthcare managers on conducting unpleasant…
Teaching about Child Labor and International Human Rights. ERIC Digest.
ERIC Educational Resources Information Center
Hamot, Gregory E.; Jensen, Elizabeth S.
An estimated 246 million children between the ages of 5 and 17 work in the agricultural, industrial, and craft sectors worldwide. Approximately 180 million of these children work under the worst forms of child labor as defined by the International Labor Organization (2002). In spite of conventions and protocols designed to eradicate the worst…
Advance Planning Briefing for Industry. Technology Requirements Briefings
2009-02-17
procedure drills through complex multiplayer interactions representative of a motorcade under heavy attack. The tool shall provide a first-person...Integrated Munitions Effect Assessment IMI Interactive Multimedia Instruction IP Internet Protocol IPE Intelligence Preparation of the Environment IR...CTTSO Programs and Mission Areas/Subgroups 13 Requirement Descriptions Blast Effects and Mitigation (BX) 16 Chemical, Biological, Radiological, and
49 CFR Appendix F to Part 240 - Medical Standards Guidelines
Code of Federal Regulations, 2013 CFR
2013-10-01
... used as signals in the railroad industry. The acceptable test methods are shown in the left hand column... these protocols, the person conducting the examination should be aware that railroad signals do not always occur in the same sequence and that “yellow signals” do not always appear to be the same. It is...
49 CFR Appendix F to Part 240 - Medical Standards Guidelines
Code of Federal Regulations, 2012 CFR
2012-10-01
... used as signals in the railroad industry. The acceptable test methods are shown in the left hand column... these protocols, the person conducting the examination should be aware that railroad signals do not always occur in the same sequence and that “yellow signals” do not always appear to be the same. It is...
49 CFR Appendix F to Part 240 - Medical Standards Guidelines
Code of Federal Regulations, 2014 CFR
2014-10-01
... used as signals in the railroad industry. The acceptable test methods are shown in the left hand column... these protocols, the person conducting the examination should be aware that railroad signals do not always occur in the same sequence and that “yellow signals” do not always appear to be the same. It is...
USDA-ARS?s Scientific Manuscript database
Commercialization of fuel ethanol production from lignocellulosic biomass has focused on engineering the glucose-fermenting industrial yeast Saccharomyces cerevisiae to utilize pentose sugars. Since S. cerevisiae naturally metabolizes xylulose, one approach involves introducing xylose isomerase (XI...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-26
... Seeks Comment on Application of the IP Closed Captioning Rules to Video Clips AGENCY: Federal... captioning of video clips delivered by Internet protocol (``IP''), including the extent to which industry has voluntarily captioned IP- delivered video clips. The Commission directed the Media Bureau to issue this...
NASA Technical Reports Server (NTRS)
Wagner, Raymond S.; Barton, Richard J.
2011-01-01
Wireless Sensor Networks (WSNs) can provide a substantial benefit in spacecraft systems, reducing launch weight and providing unprecedented flexibility by allowing instrumentation capabilities to grow and change over time. Achieving data transport reliability on par with that of wired systems, however, can prove extremely challenging in practice. Fortunately, much progress has been made in developing standard WSN radio protocols for applications from non-critical home automation to mission-critical industrial process control. The relative performances of candidate protocols must be compared in representative aerospace environments, however, to determine their suitability for spaceflight applications. In this paper, we will present the results of a rigorous laboratory analysis of the performance of two standards-based, low power, low data rate WSN protocols: ZigBee Pro and ISA100.11a. Both are based on IEEE 802.15.4 and augment that standard's specifications to build complete, multi-hop networking stacks. ZigBee Pro targets primarily the home and office automation markets, providing an ad-hoc protocol that is computationally lightweight and easy to implement in inexpensive system-on-a-chip components. As a result of this simplicity, however, ZigBee Pro can be susceptible to radio frequency (RF) interference. ISA100.11a, on the other hand, targets the industrial process control market, providing a robust, centrally-managed protocol capable of tolerating a significant amount of RF interference. To achieve these gains, a coordinated channel hopping mechanism is employed, which entails a greater computational complexity than ZigBee and requires more sophisticated and costly hardware. To guide future aerospace deployments, we must understand how well these standards relatively perform in analog environments under expected operating conditions. Specifically, we are interested in evaluating goodput -- application level throughput -- in a representative crewed environment in the presence of varying levels of 802.11g Wi-Fi traffic. To do so, we use the NASA Johnson Space Center Wireless Habitat Testbed (WHT), a metallic, habitation-sized module designed for co-existence testing of wireless systems. In its quiescent state, the sealed WHT provides an RF-quiet environment to which we can selectively add interfering systems; it also provides a realistic level of multi-path self-interference for systems under investigation. In our test, we deploy two representative five node networks, configured in a star topology with all nodes reporting directly to a WSN gateway. Each ZigBee network WSN node is built using a Texas Instruments (TI) CC2530 system-on-a-chip radio running TI's ZigBee Pro Z-stack. Each ISA100.11a network node is built using a Nivis VersaNode 210 system-on-a-chip radio. In both cases, radios interface with TI MSP430-F5438 microcontroller implementing a common test application. Interference is provided by a D-link 802.11g Wi-Fi router transporting traffic generated using the Iperf network testing tool. For the single-channel ZigBee network, effects of both direct and indirect Wi-Fi interference are evaluated. For the channel-hopping ISA100.11a network, effects of interference from multiple Wi-Fi routers configured in non-overlapping 802.11g channels are evaluated. Our results show that, in general, the more lightweight ZigBee network performs well at low interference levels, but performance degrades as interference increases. Conversely, the more complex and costly ISA100.11a network continues to perform well as Wi-Fi interference levels increase.
Biometrics based authentication scheme for session initiation protocol.
Xie, Qi; Tang, Zhixiong
2016-01-01
Many two-factor challenge-response based session initiation protocol (SIP) has been proposed, but most of them are vulnerable to smart card stolen attacks and password guessing attacks. In this paper, we propose a novel three-factor SIP authentication scheme using biometrics, password and smart card, and utilize the pi calculus-based formal verification tool ProVerif to prove that the proposed protocol achieves security and authentication. Furthermore, our protocol is highly efficient when compared to other related protocols.
Dodia, Nazera; El-Sharief, Deena; Kirwan, Cliona C
2015-01-01
Sentinel lymph nodes are mapped using (99m)Technetium, injected on day of surgery (1-day protocol) or day before (2-day protocol). This retrospective cohort study compares efficacy between the two protocols. Histopathology for all unilateral sentinel lymph node biopsies (March 2012-March 2013) in a single centre were reviewed. Number of sentinel lymph nodes, non-sentinel lymph nodes and pathology was compared. 2/270 (0.7 %) in 1-day protocol and 8/192 (4 %) in 2-day protocol had no sentinel lymph nodes removed (p = 0.02). The median (range) number of sentinel lymph nodes removed per patient was 2 (0-7) and 1 (0-11) in the 1- and 2-day protocols respectively (p = 0.08). There was a trend for removing more non-sentinel lymph nodes in 2-day protocol [1-day: 52/270 (19 %); 2-day: 50/192 (26 %), p = 0.07]. Using 2-day, sentinel lymph node identification failure rate is higher, although within acceptable rates. The 1 and 2 day protocols are both effective, therefore choice of protocol should be driven by patient convenience and hospital efficiency. However, this study raises the possibility that 1-day may be preferable when higher sentinel lymph node count is beneficial, for example following neoadjuvant chemotherapy.
Clomiphene Stair-Step Protocol for Women With Polycystic Ovary Syndrome.
Jones, Tiffanny; Ho, Jacqueline R; Gualtieri, Marc; Bruno-Gaston, Janet; Chung, Karine; Paulson, Richard J; Bendikson, Kristin A
2018-01-01
To compare time to ovulation, ovulation rates, and side effect profile of traditional and the stair-step protocol for ovulation induction using clomiphene citrate in women with polycystic ovary syndrome (PCOS). We performed a retrospective study of women seeking care for infertility with a diagnosis of PCOS at a university-based infertility clinic from July 2012 to July 2014. We included patients who were resistant to the initial starting dose of 50 mg clomiphene. The primary outcome was time to ovulation. Secondary outcomes included ovulation rates, clinical pregnancy rates, and mild and moderate-to-severe side effects based on dose. For the traditional protocol, higher doses of clomiphene were used each subsequent month if no ovulation occurred. For the stair-step protocol, higher doses of clomiphene were given 7 days after the last dose if no dominant follicles were seen on ultrasonography. Our study had 80% power to detect a 20% difference in ovulation. One hundred nine patients were included in the analysis with 66 (60.6%) in the traditional and 43 (39.4%) in the stair-step protocol. Age and body mass index were similar between groups. The time to ovulation was decreased in the stair-step protocol group compared with the traditional protocol group (23.1±0.9 days vs 47.5±6.3 days). Ovulation rates were increased in the stair-step group compared with the traditional group at 150 mg (16 [37%] vs 8 [12%], P=.004) and at 200 mg (9 [21%] vs 3 [5%], P=.01). Pregnancy rates were similar between groups once ovulation was achieved (12 [18.1%] vs 7 [16.3%], P=.08). The stair-step protocol had an increased incidence of mild side effects (vasomotor flushes, headaches, gastrointestinal disturbance, mastalgia, changes in mood; 18 [41%] vs 8 [12%]), but there was no difference in the incidence of severe side effects (headaches, visual disturbances). For women with PCOS, the stair-step clomiphene protocol is associated with decreased time to ovulation and increased ovulation rates at higher doses when compared with the traditional protocol.
A secure RFID-based WBAN for healthcare applications.
Ullah, Sana; Alamri, Atif
2013-10-01
A Wireless Body Area Network (WBAN) allows the seamless integration of small and intelligent invasive or non-invasive sensor nodes in, on or around a human body for continuous health monitoring. These nodes are expected to use different power-efficient protocols in order to extend the WBAN lifetime. This paper highlights the power consumption and security issues of WBAN for healthcare applications. Numerous power saving mechanisms are discussed and a secure RFID-based protocol for WBAN is proposed. The performance of the proposed protocol is analyzed and compared with that of IEEE 802.15.6-based CSMA/CA and preamble-based TDMA protocols using extensive simulations. It is shown that the proposed protocol is power-efficient and protects patients' data from adversaries. It is less vulnerable to different attacks compared to that of IEEE 802.15.6-based CSMA/CA and preamble-based TDMA protocols. For a low traffic load and a single alkaline battery of capacity 2.6 Ah, the proposed protocol could extend the WBAN lifetime, when deployed on patients in hospitals or at homes, to approximately five years.
Comparison of two progressive treadmill tests in patients with peripheral arterial disease.
Riebe, D; Patterson, R B; Braun, C M
2001-11-01
In a vascular rehabilitation program, 28% of our frail elderly patients are unable to be tested with traditional progressive exercise protocols at program entry due to the high (2.0 miles/h or 3.2 km/h) initial treadmill speeds. The purpose of this investigation was to compare a new progressive treadmill protocol which has a reduced initial speed (1.0 mile/h or 1.6 km/h) to an established protocol performed at 2.0 miles/h (3.2 km/h) to determine the comparability and reproducibility of the new protocol. Eleven patients with arterial claudication performed three symptom-limited exercise tests in random order. Two tests used the new protocol while the remaining trial used the established protocol. Claudication pain was measured using a 5-point scale. Oxygen consumption, heart rate, minute ventilation, respiratory exchange ratio and blood pressure at peak exercise were similar among the three trials. There were strong intraclass correlations for peak oxygen consumption (r = 0.97), onset of claudication (r = 0.96) and maximum walking time (r = 0.98) between the two trials using the new protocol. There was also a significant correlation between the new protocol and the established protocol for peak oxygen consumption (r = 0.90) and maximum walking time (r = 0.89). The new progressive treadmill protocol represents a valid, reliable protocol for patients with arterial claudication. This protocol may be useful for testing patients with a low functional capacity so that clinically appropriate exercise prescriptions can be established and the efficacy of treatments can be determined.
Semi-quantum Dialogue Based on Single Photons
NASA Astrophysics Data System (ADS)
Ye, Tian-Yu; Ye, Chong-Qiang
2018-02-01
In this paper, we propose two semi-quantum dialogue (SQD) protocols by using single photons as the quantum carriers, where one requires the classical party to possess the measurement capability and the other does not have this requirement. The security toward active attacks from an outside Eve in the first SQD protocol is guaranteed by the complete robustness of present semi-quantum key distribution (SQKD) protocols, the classical one-time pad encryption, the classical party's randomization operation and the decoy photon technology. The information leakage problem of the first SQD protocol is overcome by the classical party' classical basis measurements on the single photons carrying messages which makes him share their initial states with the quantum party. The security toward active attacks from Eve in the second SQD protocol is guaranteed by the classical party's randomization operation, the complete robustness of present SQKD protocol and the classical one-time pad encryption. The information leakage problem of the second SQD protocol is overcome by the quantum party' classical basis measurements on each two adjacent single photons carrying messages which makes her share their initial states with the classical party. Compared with the traditional information leakage resistant QD protocols, the advantage of the proposed SQD protocols lies in that they only require one party to have quantum capabilities. Compared with the existing SQD protocol, the advantage of the proposed SQD protocols lies in that they only employ single photons rather than two-photon entangled states as the quantum carriers. The proposed SQD protocols can be implemented with present quantum technologies.
Granacher, Urs; Muehlbauer, Thomas; Zahner, Lukas; Gollhofer, Albert; Kressig, Reto W
2011-05-01
Demographic change in industrialized countries produced an increase in the proportion of elderly people in our society, resulting in specific healthcare challenges. One such challenge is how to effectively deal with the increased risk of sustaining a fall and fall-related injuries in old age. Deficits in postural control and muscle strength represent important intrinsic fall risk factors. Thus, adequate training regimens need to be designed and applied that have the potential to reduce the rate of falling in older adults by countering these factors. Therefore, the purpose of this review is to compare traditional and recent approaches in the promotion of balance and strength in older adults. Traditionally, balance and resistance training programmes proved to be effective in improving balance and strength, and in reducing the number of falls. Yet, it was argued that these training protocols are not specific enough to induce adaptations in neuromuscular capacities that are specifically needed in actual balance-threatening situations (e.g. abilities to recover balance and to produce force explosively). Recent studies indicated that perturbation-based or multitask balance training and power/high-velocity resistance training have the potential to improve these specific capacities because they comply with the principle of training specificity. In fact, there is evidence that these specifically tailored training programmes are more effective in improving balance recovery mechanisms and muscle power than traditional training protocols. A few pilot studies have even shown that these recently designed training protocols have an impact on the reduction of fall incidence rate in older adults. Further research is needed to confirm these results and to elucidate the underlying mechanisms responsible for the adaptive processes.
Deposition and Characterization of Thin Films on Metallic Substrates
NASA Technical Reports Server (NTRS)
Gatica, Jorge E.
2005-01-01
A CVD method was successfully developed to produce conversion coatings on aluminum alloys surfaces with reproducible results with a variety of precursors. A well defined protocol to prepare the precursor solutions formulated in a previous research was extended to other additives. It was demonstrated that solutions prepared following such a protocol could be used to systematically generate protective coatings onto aluminum surfaces. Experiments with a variety of formulations revealed that a refined deposition protocol yields reproducible conversion coatings of controlled composition. A preliminary correlation between solution formulations and successful precursors was derived. Coatings were tested for adhesion properties enhancement for commercial paints. A standard testing method was followed and clear trends were identified. Only one precursors was tested systematically. Anticipated work on other precursors should allow a better characterization of the effect of intermetallics on the production of conversion/protective coatings on metals and ceramics. The significance of this work was the practical demonstration that chemical vapor deposition (CVD) techniques can be used to systematically generate protective/conversion coating on non-ferrous surfaces. In order to become an effective approach to replace chromate-based pre- treatment processes, namely in the aerospace or automobile industry, the process parameters must be defined more precisely. Moreover, the feasibility of scale-up designs necessitates a more comprehensive characterization of the fluid flow, transport phenomena, and chemical kinetics interacting in the process. Kinetic characterization showed a significantly different effect of magnesium-based precursors when compared to iron-based precursors. Future work will concentrate on refining the process through computer simulations and further experimental studies on the effect of other transition metals to induce deposition of conversion/protective films on aluminum and other metallic substrates.
2013-01-01
Background Pure 1, 3-diacylglycerols (1, 3-DAG) have been considered to be significant surfactants in food, cosmetics and pharmaceutical industries, as well as the effect on obesity prevention. Methods In this study, a vacuum-driven air bubbling operation mode was developed and evaluated for the enzymatic synthesis of 1, 3-DAG of saturated fatty acids, by direct esterification of glycerol with fatty acids in a solvent-free system. The employed vacuum-driven air bubbling operation mode was comparable to vacuum-driven N2 bubbling protocol, in terms of lauric acid conversion and 1, 3-dilaurin content. Results Some operation parameters were optimized, and 95.3% of lauric acid conversion and 80.3% of 1, 3-dilaurin content was obtained after 3-h reaction at 50°C, with 5 wt% of Lipozyme RM IM (based on reactants) amount. Of the lipases studied, both Lipozyme RM IM and Novozym 435 exhibited good performance in terms of lauric acid conversion. Lipozyme TL IM, however, showed low activity. Lipozyme RM IM showed good operational stability in this operation protocol, 80.2% of the original catalytic activity remained after 10 consecutive batch applications. Some other 1, 3-DAG were prepared and high content was obtained after purification: 98.5% for 1, 3-dicaprylin, 99.2% for 1, 3-dicaprin, 99.1% for 1, 3-dilaurin, 99.5 for 1, 3-dipalmitin and 99.4% for 1, 3-disterin. Conclusion The established vacuum-driven air bubbling operation protocol had been demonstrated to be a simple-operating, cost-effective, application practical and efficient methodology for 1, 3-DAG preparation. PMID:23656739
Tan, K. E.; Ellis, B. C.; Lee, R.; Stamper, P. D.; Zhang, S. X.
2012-01-01
Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate- to high-volume laboratories. PMID:22855510
Ngo, Thoai D; Park, Min Hae; Xiao, Yuanhong
2012-01-01
To compare the effectiveness, in terms of complete abortion, of the World Health Organization (WHO)- and the China-recommended protocol for first-trimester medical abortion. A retrospective analysis of clinical data from women presenting for first trimester medical abortion between January 2009 and August 2010 at reproductive health clinics in Qingdao, Xi'an, Nanjing, Nanning, and Zhengzhou was conducted. One clinic in Qingdao administered the WHO-recommended protocol (200 mg mifepristone orally followed by 0.8 mg misoprostol buccally 36-48 hours later). Four clinics in the other locations provided the China-recommended procedure (Day 1: 50 mg of mifepristone in the morning, 25 mg in the afternoon; Day 2: 50 mg of mifepristone in the morning, 25 mg in the afternoon; Day 3: 0.6 mg oral misoprostol). Data on reproductive and demographic characteristics were extracted from clinic records, and complete termination was determined on day 14 (post-mifepristone administration). A total of 337 women underwent early medical abortion (167 WHO- and 170 China-recommended procedures). Complete abortion was significantly higher among women who had the WHO protocol than those who received the China protocol (91.0% vs 77.7%, respectively; P < 0.001). Women using the China-recommended protocol were three times more likely to require an additional dose of misoprostol than women using the WHO protocol (21.8% vs 7.8%, respectively; P < 0.001), and had significantly more bleeding on the day of misoprostol administration (12.5 mL vs 18.5 mL; P < 0.001). This clinical audit provides preliminary evidence suggesting the WHO-recommended protocol may be more effective than the China-recommended protocol for early medical abortion. A larger scale study is necessary to compare the methods' effectiveness and acceptability.
Aristizabal, Paula; Singer, Jenelle; Cooper, Renee; Wells, Kristen J.; Nodora, Jesse; Milburn, Mehrzad; Gahagan, Sheila; Schiff, Deborah E.; Martinez, Maria Elena
2015-01-01
Background Survival rates in pediatric oncology have improved dramatically, in part due to high patient participation in clinical trials. Although racial/ethnic inequalities in clinical trial participation have been reported in adults, pediatric data and studies comparing participation rates by socio-demographic characteristics are scarce. The goal of this study was to assess differences in research protocol participation for childhood cancer by age, sex, race/ethnicity, parental language, cancer type and insurance status. Procedure Data on enrollment in any protocol, biospecimen, or therapeutic protocols were collected and analyzed for newly diagnosed pediatric patients with cancer from 2008–2012 at Rady Children’s Hospital. Results Among the 353 patients included in the analysis, 304 (86.1%) were enrolled in any protocol. Enrollment in biospecimen and therapeutic protocols was 84.2% (261/310) and 81.1% (206/254), respectively. Logistic regression analyses revealed significant enrollment underrepresentation in any protocol for Hispanics compared to Non-Hispanic whites (81% vs. 91%; Odds Ratio [OR], 0.43; 95% Confidence Interval [CI], 0.21–0.90; p=0.021) and among children of Spanish-speaking vs. English-speaking parents (78% vs. 89%; OR, 0.45; 95%CI, 0.23–0.87; p=0.016). Compared to patients aged 0–4 years, significant underrepresentation was also found among patients 15–21 years old (92% vs.72%; OR, 0.21; 95% CI, 0.09–0.48; p<0.001). Similar trends were observed when analyzing enrollment in biospecimen and therapeutic protocols separately. Conclusions There was significant underrepresentation in protocol participation for Hispanics, children of Spanish-speaking parents, and patients ages 15–21. Research is urgently needed to understand barriers to research participation among these groups underrepresented in pediatric oncology clinical trials. PMID:25755225
Tan, K E; Ellis, B C; Lee, R; Stamper, P D; Zhang, S X; Carroll, K C
2012-10-01
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate- to high-volume laboratories.
Evaluation of a single-scan protocol for radiochromic film dosimetry.
Shimohigashi, Yoshinobu; Araki, Fujio; Maruyama, Masato; Nakaguchi, Yuji; Kuwahara, Satoshi; Nagasue, Nozomu; Kai, Yudai
2015-03-08
The purpose of this study was to evaluate a single-scan protocol using Gafchromic EBT3 film (EBT3) by comparing it with the commonly used 24-hr measurement protocol for radiochromic film dosimetry. Radiochromic film is generally scanned 24 hr after film exposure (24-hr protocol). The single-scan protocol enables measurement results within a short time using only the verification film, one calibration film, and unirradiated film. The single-scan protocol was scanned 30 min after film irradiation. The EBT3 calibration curves were obtained with the multichannel film dosimetry method. The dose verifications for each protocol were performed with the step pattern, pyramid pattern, and clinical treatment plans for intensity-modulated radiation therapy (IMRT). The absolute dose distributions for each protocol were compared with those calculated by the treatment planning system (TPS) using gamma evaluation at 3% and 3 mm. The dose distribution for the single-scan protocol was within 2% of the 24-hr protocol dose distribution. For the step pattern, the absolute dose discrepancies between the TPS for the single-scan and 24-hr protocols were 2.0 ± 1.8 cGy and 1.4 ± 1.2 cGy at the dose plateau, respectively. The pass rates were 96.0% for the single-scan protocol and 95.9% for the 24-hr protocol. Similarly, the dose discrepancies for the pyramid pattern were 3.6 ± 3.5cGy and 2.9 ± 3.3 cGy, respectively, while the pass rates for the pyramid pattern were 95.3% and 96.4%, respectively. The average pass rates for the four IMRT plans were 96.7% ± 1.8% for the single-scan protocol and 97.3% ± 1.4% for the 24-hr protocol. Thus, the single-scan protocol measurement is useful for dose verification of IMRT, based on its accuracy and efficiency.
Evaluation of a single‐scan protocol for radiochromic film dosimetry
Araki, Fujio; Maruyama, Masato; Nakaguchi, Yuji; Kuwahara, Satoshi; Nagasue, Nozomu; Kai, Yudai
2015-01-01
The purpose of this study was to evaluate a single‐scan protocol using Gafchromic EBT3 film (EBT3) by comparing it with the commonly used 24‐hr measurement protocol for radiochromic film dosimetry. Radiochromic film is generally scanned 24 hr after film exposure (24‐hr protocol). The single‐scan protocol enables measurement results within a short time using only the verification film, one calibration film, and unirradiated film. The single‐scan protocol was scanned 30 min after film irradiation. The EBT3 calibration curves were obtained with the multichannel film dosimetry method. The dose verifications for each protocol were performed with the step pattern, pyramid pattern, and clinical treatment plans for intensity‐modulated radiation therapy (IMRT). The absolute dose distributions for each protocol were compared with those calculated by the treatment planning system (TPS) using gamma evaluation at 3% and 3 mm. The dose distribution for the single‐scan protocol was within 2% of the 24‐hr protocol dose distribution. For the step pattern, the absolute dose discrepancies between the TPS for the single‐scan and 24‐hr protocols were 2.0±1.8 cGy and 1.4±1.2 cGy at the dose plateau, respectively. The pass rates were 96.0% for the single‐scan protocol and 95.9% for the 24‐hr protocol. Similarly, the dose discrepancies for the pyramid pattern were 3.6±3.5 cGy and 2.9±3.3 cGy, respectively, while the pass rates for the pyramid pattern were 95.3% and 96.4%, respectively. The average pass rates for the four IMRT plans were 96.7%±1.8% for the single‐scan protocol and 97.3%±1.4% for the 24‐hr protocol. Thus, the single‐scan protocol measurement is useful for dose verification of IMRT, based on its accuracy and efficiency. PACS number: 87.55.Qr PMID:26103194
Green, Esther; Ballantyne, Barbara; Tarasuk, Joy; Skrutkowski, Myriam; Carley, Meg; Chapman, Kim; Kuziemsky, Craig; Kolari, Erin; Sabo, Brenda; Saucier, Andréanne; Shaw, Tara; Tardif, Lucie; Truant, Tracy; Cummings, Greta G.; Howell, Doris
2016-01-01
ABSTRACT Background The pan‐Canadian Oncology Symptom Triage and Remote Support (COSTaRS) team developed 13 evidence‐informed protocols for symptom management. Aim To build an effective and sustainable approach for implementing the COSTaRS protocols for nurses providing telephone‐based symptom support to cancer patients. Methods A comparative case study was guided by the Knowledge to Action Framework. Three cases were created for three Canadian oncology programs that have nurses providing telephone support. Teams of researchers and knowledge users: (a) assessed barriers and facilitators influencing protocol use, (b) adapted protocols for local use, (c) intervened to address barriers, (d) monitored use, and (e) assessed barriers and facilitators influencing sustained use. Analysis was within and across cases. Results At baseline, >85% nurses rated protocols positively but barriers were identified (64‐80% needed training). Patients and families identified similar barriers and thought protocols would enhance consistency among nurses teaching self‐management. Twenty‐two COSTaRS workshops reached 85% to 97% of targeted nurses (N = 119). Nurses felt more confident with symptom management and using the COSTaRS protocols (p < .01). Protocol adaptations addressed barriers (e.g., health records approval, creating pocket versions, distributing with telephone messages). Chart audits revealed that protocols used were documented for 11% to 47% of patient calls. Sustained use requires organizational alignment and ongoing leadership support. Linking Evidence to Action Protocol uptake was similar to trials that have evaluated tailored interventions to improve professional practice by overcoming identified barriers. Collaborating with knowledge users facilitated interpretation of findings, aided protocol adaptation, and supported implementation. Protocol implementation in nursing requires a tailored approach. A multifaceted intervention approach increased nurses’ use of evidence‐informed protocols during telephone calls with patients about symptoms. Training and other interventions improved nurses’ confidence with using COSTaRS protocols and their uptake was evident in some documented telephone calls. Protocols could be adapted for use by patients and nurses globally. PMID:27243574
Dynamic sentinel lymph node biopsy for penile cancer: a comparison between 1- and 2-day protocols.
Dimopoulos, Panagiotis; Christopoulos, Panagiotis; Shilito, Sam; Gall, Zara; Murby, Brian; Ashworth, David; Taylor, Ben; Carrington, Bernadette; Shanks, Jonathan; Clarke, Noel; Ramani, Vijay; Parr, Nigel; Lau, Maurice; Sangar, Vijay
2016-06-01
To determine the outcome of clinically negative node (cN0) patients with penile cancer undergoing dynamic sentinel node biopsy (DSNB), comparing the results of a 1- and 2-day protocol that can be used as a minimal invasive procedure for staging of penile cancer. This is a retrospective analysis of 151 cN0 patients who underwent DSNB from 2008 to 2013 for newly diagnosed penile cancer. Data were analysed per groin and separated into groups according to the protocol followed. The comparison of the two protocols involved the number of nodes excised, γ-counts, false-negative rates (FNR), and complication rates (Clavien-Dindo grading system). In all, 280 groins from 151 patients underwent DSNB after a negative ultrasound ± fine-needle aspiration cytology. The 1-day protocol was performed in 65 groins and the 2-day protocol in 215. Statistically significantly more nodes were harvested with the 1-day protocol (1.92/groin) compared with the 2-day protocol (1.60/groin). The FNRs were 0%, 6.8% and 5.1%, for the 1-day protocol, 2-day protocol, and overall, respectively. Morbidity of the DSNB was 21.4% for all groins, and 26.2% and 20.1% for the 1-day and 2-day protocols, respectively. Most of the complications were of Clavien-Dindo Grade 1-2. DSNB is safe for staging patients with penile cancer. There is a trend towards a 1-day protocol having a lower FNR than a 2-day protocol, albeit at the expense of a slightly higher complication rate. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Sangroh; Yoo, Sua; Yin Fangfang
2010-07-15
Purpose: To assess imaging dose of partial and full-angle kilovoltage CBCT scan protocols and to evaluate image quality for each protocol. Methods: The authors obtained the CT dose index (CTDI) of the kilovoltage CBCT protocols in an on-board imager by ion chamber (IC) measurements and Monte Carlo (MC) simulations. A total of six new CBCT scan protocols were evaluated: Standard-dose head (100 kVp, 151 mA s, partial-angle), low-dose head (100 kVp, 75 mA s, partial-angle), high-quality head (100 kVp, 754 mA s, partial-angle), pelvis (125 kVp, 706 mA s, full-angle), pelvis spotlight (125 kVp, 752 mA s, partial-angle), and low-dosemore » thorax (110 kVp, 271 mA s, full-angle). Using the point dose method, various CTDI values were calculated by (1) the conventional weighted CTDI (CTDI{sub w}) calculation and (2) Bakalyar's method (CTDI{sub wb}). The MC simulations were performed to obtain the CTDI{sub w} and CTDI{sub wb}, as well as from (3) central slice averaging (CTDI{sub 2D}) and (4) volume averaging (CTDI{sub 3D}) techniques. The CTDI values of the new protocols were compared to those of the old protocols (full-angle CBCT protocols). Image quality of the new protocols was evaluated following the CBCT image quality assurance (QA) protocol [S. Yoo et al., ''A quality assurance program for the on-board imager registered ,'' Med. Phys. 33(11), 4431-4447 (2006)] testing Hounsfield unit (HU) linearity, spatial linearity/resolution, contrast resolution, and HU uniformity. Results: The CTDI{sub w} were found as 6.0, 3.2, 29.0, 25.4, 23.8, and 7.7 mGy for the new protocols, respectively. The CTDI{sub w} and CTDI{sub wb} differed within +3% between IC measurements and MC simulations. Method (2) results were within {+-}12% of method (1). In MC simulations, the CTDI{sub w} and CTDI{sub wb} were comparable to the CTDI{sub 2D} and CTDI{sub 3D} with the differences ranging from -4.3% to 20.6%. The CTDI{sub 3D} were smallest among all the CTDI values. CTDI{sub w} of the new protocols were found as {approx}14 times lower for standard head scan and 1.8 times lower for standard body scan than the old protocols, respectively. In the image quality QA tests, all the protocols except low-dose head and low-dose thorax protocols were within the tolerance in the HU verification test. The HU value for the two protocols was always higher than the nominal value. All the protocols passed the spatial linearity/resolution and HU uniformity tests. In the contrast resolution test, only high-quality head and pelvis scan protocols were within the tolerance. In addition, crescent effect was found in the partial-angle scan protocols. Conclusions: The authors found that CTDI{sub w} of the new CBCT protocols has been significantly reduced compared to the old protocols with acceptable image quality. The CTDI{sub w} values in the point dose method were close to the volume averaging method within 9%-21% for all the CBCT scan protocols. The Bakalyar's method produced more accurate dose estimation within 14%. The HU inaccuracy from low-dose head and low-dose thorax protocols can render incorrect dose results in the treatment planning system. When high soft-tissue contrast data are desired, high-quality head or pelvis scan protocol is recommended depending on the imaging area. The point dose method can be applicable to estimate CBCT dose with reasonable accuracy in the clinical environment.« less
A Survey on an Energy-Efficient and Energy-Balanced Routing Protocol for Wireless Sensor Networks.
Ogundile, Olayinka O; Alfa, Attahiru S
2017-05-10
Wireless sensor networks (WSNs) form an important part of industrial application. There has been growing interest in the potential use of WSNs in applications such as environment monitoring, disaster management, health care monitoring, intelligence surveillance and defence reconnaissance. In these applications, the sensor nodes (SNs) are envisaged to be deployed in sizeable numbers in an outlying area, and it is quite difficult to replace these SNs after complete deployment in many scenarios. Therefore, as SNs are predominantly battery powered devices, the energy consumption of the nodes must be properly managed in order to prolong the network lifetime and functionality to a rational time. Different energy-efficient and energy-balanced routing protocols have been proposed in literature over the years. The energy-efficient routing protocols strive to increase the network lifetime by minimizing the energy consumption in each SN. On the other hand, the energy-balanced routing protocols protract the network lifetime by uniformly balancing the energy consumption among the nodes in the network. There have been various survey papers put forward by researchers to review the performance and classify the different energy-efficient routing protocols for WSNs. However, there seems to be no clear survey emphasizing the importance, concepts, and principles of load-balanced energy routing protocols for WSNs. In this paper, we provide a clear picture of both the energy-efficient and energy-balanced routing protocols for WSNs. More importantly, this paper presents an extensive survey of the different state-of-the-art energy-efficient and energy-balanced routing protocols. A taxonomy is introduced in this paper to classify the surveyed energy-efficient and energy-balanced routing protocols based on their proposed mode of communication towards the base station (BS). In addition, we classified these routing protocols based on the solution types or algorithms, and the input decision variables defined in the routing algorithm. The strengths and weaknesses of the choice of the decision variables used in the design of these energy-efficient and energy-balanced routing protocols are emphasised. Finally, we suggest possible research directions in order to optimize the energy consumption in sensor networks.
A Survey on an Energy-Efficient and Energy-Balanced Routing Protocol for Wireless Sensor Networks
Ogundile, Olayinka O.; Alfa, Attahiru S.
2017-01-01
Wireless sensor networks (WSNs) form an important part of industrial application. There has been growing interest in the potential use of WSNs in applications such as environment monitoring, disaster management, health care monitoring, intelligence surveillance and defence reconnaissance. In these applications, the sensor nodes (SNs) are envisaged to be deployed in sizeable numbers in an outlying area, and it is quite difficult to replace these SNs after complete deployment in many scenarios. Therefore, as SNs are predominantly battery powered devices, the energy consumption of the nodes must be properly managed in order to prolong the network lifetime and functionality to a rational time. Different energy-efficient and energy-balanced routing protocols have been proposed in literature over the years. The energy-efficient routing protocols strive to increase the network lifetime by minimizing the energy consumption in each SN. On the other hand, the energy-balanced routing protocols protract the network lifetime by uniformly balancing the energy consumption among the nodes in the network. There have been various survey papers put forward by researchers to review the performance and classify the different energy-efficient routing protocols for WSNs. However, there seems to be no clear survey emphasizing the importance, concepts, and principles of load-balanced energy routing protocols for WSNs. In this paper, we provide a clear picture of both the energy-efficient and energy-balanced routing protocols for WSNs. More importantly, this paper presents an extensive survey of the different state-of-the-art energy-efficient and energy-balanced routing protocols. A taxonomy is introduced in this paper to classify the surveyed energy-efficient and energy-balanced routing protocols based on their proposed mode of communication towards the base station (BS). In addition, we classified these routing protocols based on the solution types or algorithms, and the input decision variables defined in the routing algorithm. The strengths and weaknesses of the choice of the decision variables used in the design of these energy-efficient and energy-balanced routing protocols are emphasised. Finally, we suggest possible research directions in order to optimize the energy consumption in sensor networks. PMID:28489054
O'Neill-Kerr, Alex; Yassin, Anhar; Rogers, Stephen; Cornish, Janie
2017-09-01
The aim of this study was to test the proposition that adoption of a dose titration protocol may be associated with better patient outcomes, at lower treatment dose, and with comparable cumulative dose to that in patients treated using an age-based stimulus dosing protocol. This was an analysis of data assembled from archived records and based on cohorts of patients treated respectively on an age-based stimulus dosing protocol and on a dose titration protocol in the National Health Service in England. We demonstrated a significantly better response in the patient cohort treated with dose titration than with age-based stimulus dosing. Peak doses were less and the total cumulative dose was less in the dose titration group than in the age-based stimulus dosing group. Our findings are consistent with superior outcomes in patients treated using a dose titration protocol when compared with age-based stimulus dosing in a similar cohort of patients.
Verhoeven, Karolien; Weltens, Caroline; Van den Heuvel, Frank
2015-01-01
Quantification of the setup errors is vital to define appropriate setup margins preventing geographical misses. The no‐action–level (NAL) correction protocol reduces the systematic setup errors and, hence, the setup margins. The manual entry of the setup corrections in the record‐and‐verify software, however, increases the susceptibility of the NAL protocol to human errors. Moreover, the impact of the skin mobility on the anteroposterior patient setup reproducibility in whole‐breast radiotherapy (WBRT) is unknown. In this study, we therefore investigated the potential of fixed vertical couch position‐based patient setup in WBRT. The possibility to introduce a threshold for correction of the systematic setup errors was also explored. We measured the anteroposterior, mediolateral, and superior–inferior setup errors during fractions 1–12 and weekly thereafter with tangential angled single modality paired imaging. These setup data were used to simulate the residual setup errors of the NAL protocol, the fixed vertical couch position protocol, and the fixed‐action–level protocol with different correction thresholds. Population statistics of the setup errors of 20 breast cancer patients and 20 breast cancer patients with additional regional lymph node (LN) irradiation were calculated to determine the setup margins of each off‐line correction protocol. Our data showed the potential of the fixed vertical couch position protocol to restrict the systematic and random anteroposterior residual setup errors to 1.8 mm and 2.2 mm, respectively. Compared to the NAL protocol, a correction threshold of 2.5 mm reduced the frequency of mediolateral and superior–inferior setup corrections with 40% and 63%, respectively. The implementation of the correction threshold did not deteriorate the accuracy of the off‐line setup correction compared to the NAL protocol. The combination of the fixed vertical couch position protocol, for correction of the anteroposterior setup error, and the fixed‐action–level protocol with 2.5 mm correction threshold, for correction of the mediolateral and the superior–inferior setup errors, was proved to provide adequate and comparable patient setup accuracy in WBRT and WBRT with additional LN irradiation. PACS numbers: 87.53.Kn, 87.57.‐s
ICONE: An International Consortium of Neuro Endovascular Centres.
Raymond, J; White, P; Kallmes, D F; Spears, J; Marotta, T; Roy, D; Guilbert, F; Weill, A; Nguyen, T; Molyneux, A J; Cloft, H; Cekirge, S; Saatci, I; Bracard, S; Meder, J F; Moret, J; Cognard, C; Qureshi, A I; Turk, A S; Berenstein, A
2008-06-30
The proliferation of new endovascular devices and therapeutic strategies calls for a prudentand rational evaluation of their clinical benefit. This evaluation must be done in an effective manner and in collaboration with industry. Such research initiative requires organisation a land methodological support to survive and thrive in a competitive environment. We propose the formation of an international consortium, an academic alliance committed to the pursuit of effective neurovascular therapies. Such a consortium would be dedicated to the designand execution of basic science, device developmentand clinical trials. The Consortium is owned and operated by its members. Members are international leaders in neurointerventional research and clinical practice. The Consortium brings competency, knowledge, and expertise to industry as well as to its membership across aspectrum of research initiatives such as: expedited review of clinical trials, protocol development, surveys and systematic reviews; laboratory expertise and support for research design and grant applications to public agencies. Once objectives and protocols are approved, the Consortium provides a stable network of centers capable of timely realization of clinical trials or pre clinical investigations in an optimal environment. The Consortium is a non-profit organization. The potential revenue generated from clientsponsored financial agreements will be redirected to the academic and research objectives of the organization. The Consortium wishes to work inconcert with industry, to support emerging trends in neurovascular therapeutic development. The Consortium is a realistic endeavour optimally structured to promote excellence through scientific appraisal of our treatments, and to accelerate technical progress while maximizing patients' safety and welfare.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castillo, M.; Alonso, M.C.; Riu, J.
1999-04-15
This paper presents a generic protocol for the determination of polar, ionic, and highly water soluble organic pollutants on untreated industrial wastewaters involving the use of two different solid-phase extraction (SPE) methodologies followed by liquid chromatography-mass spectrometry (LC-MS). Untreated industrial wastewaters might contain natural and synthetic dissolved organic compounds with total organic carbon (TOC) values varying between 100 and 3000 mg/L. All polar, ionic and highly water soluble compounds comprising more than 95% of the organic content and with major contribution to the total toxicity of the sample cannot be analyzed by conventional gas chromatography-mass spectrometry (GC-MS), and LC-MS ismore » a good alternative. In this work two extraction procedures were used to obtain fractionated extracts of the nonionic polar compounds: a polymeric Isolute ENV + SPE cartridge for the preconcentration of anionic analytes and a sequential solid-phase extraction (SSPE) method percolating the samples first in octadecylsilica cartridge in series with the polymeric Lichrolut EN cartridge. Average recoveries ranging from 72% to 103% were obtained for a variety of 23 different analytes. Determination of nonionic pollutants was accomplished by reverse-phase liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS), while anionic compounds were analyzed by ion pair chromatography-electrospray-mass spectrometry (IP-ESI-MS) and LC-ESI-MS. This protocol was applied to a pilot survey of textile and tannery wastewaters leading to the identification and quantification of 33 organic pollutants.« less
Tan, J S P; Tan, K-L; Lee, J C L; Wan, C-M; Leong, J-L; Chan, L-L
2009-02-01
To our knowledge, there has been no study that compares the radiation dose delivered to the eye lens by 16- and 64-section multidetector CT (MDCT) for standard clinical neuroimaging protocols. Our aim was to assess radiation-dose differences between 16- and 64-section MDCT from the same manufacturer, by using near-identical neuroimaging protocols. Three cadaveric heads were scanned on 16- and 64-section MDCT by using standard neuroimaging CT protocols. Eye lens dose was measured by using thermoluminescent dosimeters (TLD), and each scanning was repeated to reduce random error. The dose-length product, volume CT dose index (CTDI(vol)), and TLD readings for each imaging protocol were averaged and compared between scanners and protocols, by using the paired Student t test. Statistical significance was defined at P < .05. The radiation dose delivered and eye lens doses were lower by 28.1%-45.7% (P < .000) on the 64-section MDCT for near-identical imaging protocols. On the 16-section MDCT, lens dose reduction was greatest (81.1%) on a tilted axial mode, compared with a nontilted helical mode for CT brain scans. Among the protocols studied, CT of the temporal bone delivered the greatest radiation dose to the eye lens. Eye lens radiation doses delivered by the 64-section MDCT are significantly lower, partly due to improvements in automatic tube current modulation technology. However, where applicable, protection of the eyes from the radiation beam by either repositioning the head or tilting the gantry remains the best way to reduce eye lens dose.
Polyethylene glycol 3350 based colon cleaning protocol: 2 d vs 4 d head to head comparison.
Elitsur, Rotem; Butcher, Lisa; Vicki, Lund; Elitsur, Yoram
2013-04-16
To compare between 2 and 4 d colon cleansing protocols. Children who were scheduled for colonoscopy procedure (2010-2012) for various medical reasons, were recruited from the pediatric gastroenterology clinic at Marshall University School of Medicine, Huntington, WV. Exclusion criteria were patients who were allergic to the medication used in the protocols [polyethylene glycol (PEG) 3350, Bisacodyl], or children with metabolic or renal diseases. Two PEG 3350 protocols for 4 d (A) and 2 d (B) were prescribed as previously described. A questionnaire describing the volume of PEG consumed, clinical data, and side effects were recorded. Colon preparation was graded by two observers according to previously described method. Rate of adequate colon preparation. A total of 78 patients were considered for final calculation (group A: 40, group B: 38). Age and stool consistency at the last day was comparable in both groups, but the number of stools/day was significantly higher in group B (P = 0.001). Adequate colon preparation was reached in 57.5% (A) and 73.6% (B), respectively (P = 0.206). Side effects were minimal and comparable in both groups. There was no difference in children's age, stool characteristics, or side effects between the children with adequate or inadequate colon preparation. Correlation and agreement between observers was excellent (Pearson correlation = 0.972, kappa = 1.0). No difference between protocols was observed, but the 2 d protocol was superior for its shorter time. Direct comparison between different colon cleansing protocols is crucial in order to establish the "gold standard" protocol for children.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKane, Aimee; Scheihing, Paul; Williams, Robert
2007-07-01
More than fifteen years after the launch of programs in theU.K. and U.S., industry still offers one of the largest opportunities forenergy savings worldwide. The International Energy Agency (IEA) estimatesthe savings potential from cost-optimization of industrial motor-drivensystems alone at 7 percent of global electricity use. The U.S. Departmentof Energy (USDOE) Industrial Technologies Program estimates 7 percentsavings potential in total US industrial energy use through theapplication of proven best practice. Simple paybacks for these types ofprojects are frequently two years or less. The technology required toachieve these savings is widely available; the technical skills requiredto identify energy saving opportunities are knownmore » and transferable.Although programs like USDOE's Best Practices have been highlysuccessful, most plants, as supported by 2002 MECS data, remain eitherunaware or unmotivated to improve their energy efficiency--as evidencedby the 98 percent of US industrial facilities reporting to MECS say thatthey lack a full-time energy manager. With the renewed interest in energyefficiency worldwide and the emergence of carbon trading and newfinancial instruments such as white certificates1, there is a need tointroduce greater transparency into the way that industrial facilitiesidentify, develop, and document energy efficiency projects. Historically,industrial energy efficiency projects have been developed by plantengineers, frequently with assistance from consultants and/or supplierswith highly specialized technical skills. Under this scenario,implementation of energy efficiency improvements is dependent onindividuals. These individuals typically include "champions" within anindustrial facility or corporation, working in cooperation withconsultants or suppliers who have substantial knowledge based on years ofexperience. This approach is not easily understood by others without thisspecialized technical knowledge, penetrates the market fairly slowly, andhas no assurance of persistence, since champions may leave the company orbe reassigned after project completion.This paper presents an alternatescenario that builds on the body of expert knowledge concerning energymanagement best practices and the experience of industrial champions toengage industry in continuous energy efficiency improvement at thefacility rather than the individual level. Under this scenario,standardized methodologies for applying and validating energy managementbest practices in industrial facilities will be developed through aconsensus process involving both plant personnel and specializedconsultants and suppliers. The resulting protocols will describe aprocess or framework for conducting an energy savings assessment andverifying the results that will be transparent to policymakers, managers,and the financial community, and validated by a third-party organization.Additionally, a global dialogue is being initiated by the United NationsIndustrial Development Organization (UNIDO) concerning the development ofan international industrial energy management standard that would be ISOcompatible. The proposed scenario will combine the resulting standardwith the best practice protocols for specific energy systems (i.e.,steam, process heating, compressed air, pumping systems, etc.) to formthe foundation of a third party, performance-based certification programfor the overall industrial facility that is compatible with existingmanagement systems, including ISO 9001:2000, 14001:2004 and 6 Sigma. Thelong term goal of this voluntary, industry designed certification programis to develop a transparent, globally accepted system for validatingenergy efficiency projects and management practices. This system wouldcreate a verified record of energy savings with potential market valuethat could be recognized among sectors and countries.« less
Birk, Thomas; Guldner, Karlheinz; Mundt, Kenneth A; Dahmann, Dirk; Adams, Robert C; Parsons, William
2010-09-01
A time-dependent quantitative exposure assessment of silica exposure among nearly 18,000 German porcelain workers was conducted. Results will be used to evaluate exposure-response disease risks. Over 8000 historical industrial hygiene (IH) measurements with original sampling and analysis protocols from 1954-2006 were obtained from the German Berufs- genossenschaft der keramischen-und Glas-Industrie (BGGK) and used to construct a job exposure matrix (JEM). Early measurements from different devices were converted to modern gravimetric equivalent values. Conversion factors were derived from parallel historical measurements and new side-by-side measurements using historical and modern devices in laboratory dust tunnels and active workplace locations. Exposure values were summarized and smoothed using LOESS regression; estimates for early years were derived using backward extrapolation techniques. Employee work histories were merged with JEM values to determine cumulative crystalline silica exposures for cohort members. Average silica concentrations were derived for six primary similar exposure groups (SEGs) for 1938-2006. Over 40% of the cohort accumulated <0.5 mg; just over one-third accumulated >1 mg/m(3)-years. Nearly 5000 workers had cumulative crystalline silica estimates >1.5 mg/m(3)-years. Similar numbers of men and women fell into each cumulative exposure category, except for 1113 women and 1567 men in the highest category. Over half of those hired before 1960 accumulated >3 mg/m(3)-years crystalline silica compared with 4.9% of those hired after 1960. Among those ever working in the materials preparation area, half accumulated >3 mg/m(3)-year compared with 12% of those never working in this area. Quantitative respirable silica exposures were estimated for each member of this cohort, including employment periods for which sampling used now obsolete technologies. Although individual cumulative exposure estimates ranged from background to about 40 mg/m(3)-years, many of these estimates reflect long-term exposures near modern exposure limit values, allowing direct evaluation of lung cancer and silicosis risks near these limits without extrapolation. This quantitative exposure assessment is the largest to date in the porcelain industry.
Hennessey, Morgan; Lee, Brendan; Goldsmith, Timothy; Halvorson, Dave; Hueston, William; McElroy, Kristina; Waters, Katherine
2010-03-01
Since 2006, a collaborative group of egg industry, state, federal, and academia representatives have worked to enhance preparedness in highly pathogenic avian influenza (HPAI) planning. The collaborative group has created a draft egg product movement protocol, which calls for realistic, science-based contingency plans, biosecurity assessments, commodity risk assessments, and real-time reverse transcriptase-PCR testing to support the continuity of egg operations while also preventing and eradicating an HPAI outbreak. The work done by this group serves as an example of how industry, government, and academia can work together to achieve better preparedness in the event of an animal health emergency. In addition, in the event of an HPAI outbreak in domestic poultry, U.S. consumers will be assured that their egg products come from healthy chickens.
Qu, Shu-Gen; Gao, Jin; Tang, Bo; Yu, Bo; Shen, Yue-Ping; Tu, Yu
2018-05-01
Low-dose ionizing radiation (LDIR) may increase the mortality of solid cancers in nuclear industry workers, but only few individual cohort studies exist, and the available reports have low statistical power. The aim of the present study was to focus on solid cancer mortality risk from LDIR in the nuclear industry using standard mortality ratios (SMRs) and 95% confidence intervals. A systematic literature search through the PubMed and Embase databases identified 27 studies relevant to this meta-analysis. There was statistical significance for total, solid and lung cancers, with meta-SMR values of 0.88, 0.80, and 0.89, respectively. There was evidence of stochastic effects by IR, but more definitive conclusions require additional analyses using standardized protocols to determine whether LDIR increases the risk of solid cancer-related mortality.
Comparison of 2 intravenous insulin protocols: Glycemia variability in critically ill patients.
Gómez-Garrido, Marta; Rodilla-Fiz, Ana M; Girón-Lacasa, María; Rodríguez-Rubio, Laura; Martínez-Blázquez, Anselmo; Martínez-López, Fernando; Pardo-Ibáñez, María Dolores; Núñez-Marín, Juan M
2017-05-01
Glycemic variability is an independent predictor of mortality in critically ill patients. The objective of this study was to compare two intravenous insulin protocols in critically ill patients regarding the glycemic variability. This was a retrospective observational study performed by reviewing clinical records of patients from a Critical Care Unit for 4 consecutive months. First, a simpler Scale-Based Intravenous Insulin Protocol (SBIIP) was reviewed and later it was compared for the same months of the following year with a Sliding Scale-Based Intravenous Insulin Protocol (SSBIIP). All adult patients admitted to the unit during the referred months were included. Patients in whom the protocol was not adequately followed were excluded. A total of 557 patients were reviewed, of whom they had needed intravenous insulin 73 in the first group and 52 in the second group. Four and two patients were excluded in each group respectively. Glycemic variability for both day 1 (DS1) and total stay (DST) was lower in SSBIIP patients compared to SBIIP patients: SD1 34.88 vs 18.16 and SDT 36.45 vs 23.65 (P<.001). A glycemic management protocol in critically ill patients based on sliding scales decreases glycemic variability. Copyright © 2017 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.
KENDALL, BRADLEY J.
2017-01-01
The Wingate Anaerobic Test (WAnT) has been used in many studies to determine anaerobic performance. However, there has been poor reporting of warm-up protocols and limited consistency between warm-up methods that have been used. With the WAnT being such a commonly-used test, consistency in warm-up methods is essential in order to compare results across studies. Therefore, this study was designed to compare how static stretching, dynamic stretching, and an active warm-up affect WAnT performance. Ten recreationally active participants (5 males, 5 females) with a mean (SD) age of 23.3 (0.7) volunteered for this study. Subjects were randomized to a specific order of five warm-up protocols, which were performed on individual days followed by a WAnT. Peak power, mean power, power drop, and fatigue index were compared for each trial using a repeated measures ANOVA. For peak power, results revealed that warm-up protocol had a significant effect, F(4,36) = 3.90, p = .01, partial η2 = .302. It was hypothesized that the dynamic stretching would lead to greater peak power than the static stretching protocol. However, results of post hoc analyses failed to detect a significant difference (p =.065). For the other measured variables no significant differences were found. The findings from this study suggest that warm-up protocols may have significantly different impacts on peak power during the WAnT. Additional research should use larger sample sizes and further explore these warm-up protocols. Developing a standardized warm-up protocol for the WAnT may improve consistency between studies. PMID:28479947
Evaluation of Modified 2-Tiered Serodiagnostic Testing Algorithms for Early Lyme Disease
Strle, Klemen; Nigrovic, Lise E.; Lantos, Paul M.; Lepore, Timothy J.; Damle, Nitin S.; Ferraro, Mary Jane; Steere, Allen C.
2017-01-01
Abstract Background. The conventional 2-tiered serologic testing protocol for Lyme disease (LD), an enzyme immunoassay (EIA) followed by immunoglobulin M and immunoglobulin G Western blots, performs well in late-stage LD but is insensitive in patients with erythema migrans (EM), the most common manifestation of the illness. Western blots are also complex, difficult to interpret, and relatively expensive. In an effort to improve test performance and simplify testing in early LD, we evaluated several modified 2-tiered testing (MTTT) protocols, which use 2 assays designed as first-tier tests sequentially, without the need of Western blots. Methods. The MTTT protocols included (1) a whole-cell sonicate (WCS) EIA followed by a C6 EIA; (2) a WCS EIA followed by a VlsE chemiluminescence immunoassay (CLIA); and (3) a variable major protein-like sequence, expressed (VlsE) CLIA followed by a C6 EIA. Sensitivity was determined using serum from 55 patients with erythema migrans; specificity was determined using serum from 50 patients with other illnesses and 1227 healthy subjects. Results. Sensitivity of the various MTTT protocols in patients with acute erythema migrans ranged from 36% (95% confidence interval [CI], 25%–50%) to 54% (95% CI, 42%–67%), compared with 25% (95% CI, 16%–38%) using the conventional protocol (P = .003–0.3). Among control subjects, the 3 MTTT protocols were similarly specific (99.3%–99.5%) compared with conventional 2-tiered testing (99.5% specificity; P = .6–1.0). Conclusions. Although there were minor differences in sensitivity and specificity among MTTT protocols, each provides comparable or greater sensitivity in acute EM, and similar specificity compared with conventional 2-tiered testing, obviating the need for Western blots. PMID:28329259
Williams, N; Coburn, J; Gillum, T
2015-11-01
The aim of this paper was to determine if two different warm-up protocols differently affect torque of the quadriceps and hamstrings, and electromyography (EMG) output of the rectus femoris (RF) and vastus lateralis (VL) when completing 30 maximal leg extensions and curls. Twenty-one healthy male (N.=8) and female (N.=13) subjects volunteered to participate in a familiarization session and three testing sessions. The three testing sessions control, dynamic, and static were completed in a counterbalanced order on non-consecutive days. First, subjects warmed-up on a treadmill for five minutes before completing six dynamic movements, six static-stretches, or no stretches. They then rested for five minutes before completing 30 maximal leg extensions and curls at a speed of 60 s-1. A significant decrease in quadriceps torque output over time was determined for the dynamic protocol when compared to the control (P<0.01) and static (P<0.05) protocols. A significant decrease was found in peak quadriceps torque for the dynamic protocol (P<0.01) when compared to the static, and a significant increase was found for the static protocol (P<0.05) when compared to the control. A significant decrease in average quadriceps torque was found for the dynamic protocol when compared to the static (P<0.05) and control (P<0.01) protocols. No difference was found in hamstring torque or EMG output of the RF and VL. Short duration static-stretching has the ability to increase peak and average torque of the leg extensors, while some types of anaerobic exercise involving maximal contractions to fatigue may be hindered by performing dynamic movements as part of the warm-up.
Kendall, Bradley J
2017-01-01
The Wingate Anaerobic Test (WAnT) has been used in many studies to determine anaerobic performance. However, there has been poor reporting of warm-up protocols and limited consistency between warm-up methods that have been used. With the WAnT being such a commonly-used test, consistency in warm-up methods is essential in order to compare results across studies. Therefore, this study was designed to compare how static stretching, dynamic stretching, and an active warm-up affect WAnT performance. Ten recreationally active participants (5 males, 5 females) with a mean (SD) age of 23.3 (0.7) volunteered for this study. Subjects were randomized to a specific order of five warm-up protocols, which were performed on individual days followed by a WAnT. Peak power, mean power, power drop, and fatigue index were compared for each trial using a repeated measures ANOVA. For peak power, results revealed that warm-up protocol had a significant effect, F (4,36) = 3.90, p = .01, partial η 2 = .302. It was hypothesized that the dynamic stretching would lead to greater peak power than the static stretching protocol. However, results of post hoc analyses failed to detect a significant difference (p =.065). For the other measured variables no significant differences were found. The findings from this study suggest that warm-up protocols may have significantly different impacts on peak power during the WAnT. Additional research should use larger sample sizes and further explore these warm-up protocols. Developing a standardized warm-up protocol for the WAnT may improve consistency between studies.
Chen, Xiao; Geng, Ling; Li, Hong
2014-04-01
To compare the clinical outcomes and cost-effectiveness of luteal phase down-regulation with gonadotrophin-releasing hormone (GnRH) agonist protocol and GnRH antagonist protocol in patients undergoing repeated in vitro fertilization and intracytoplasmic sperm injection (IVF-ICSI) cycles. A retrospective analysis of clinical outcomes and costs was conducted among 198 patients undergoing repeated IVF-ICSI cycles, including 109 receiving luteal phase down-regulation with GnRH agonist protocol (group A) and 89 receiving GnRH antagonist protocol (group B). The numbers of oocytes retrieved and good embryos, clinical pregnancy rate, abortion rate, the live birth rate, mean total cost, and the cost-effective ratio were compared between the two groups. In patients undergoing repeated IVF-ICSI cycles, the two protocols produced no significant differences in the number of good embryos, clinical pregnancy rate, abortion rate, or twin pregnancy rate. Compared with group B, group A had better clinical outcomes though this difference was not statistically significant. The number of retrieved oocytes was significantly greater and live birth rate significantly higher in group A than in group B (9.13=4.98 vs 7.11=4.74, and 20.2% vs 9.0%, respectively). Compared with group B, group A had higher mean total cost per cycle but lower costs for each oocyte retrieved (2729.11 vs 3038.60 RMB yuan), each good embryo (8867.19 vs 9644.85 RMB yuan), each clinical pregnancy (77598.06 vs 96139.85 RMB yuan). For patients undergoing repeated IVF/ICSI cycle, luteal phase down-regulation with GnRH agonist protocol produces good clinical outcomes with also good cost-effectiveness in spite an unsatisfactory ovarian reserve.
Participation of Asian-American women in cancer treatment research: a pilot study.
Nguyen, Tung T; Somkin, Carol P; Ma, Yifei; Fung, Lei-Chun; Nguyen, Thoa
2005-01-01
Few Asian-American women participate in cancer treatment trials. In a pilot study to assess barriers to participation, we mailed surveys to 132 oncologists and interviewed 19 Asian-American women with cancer from Northern California. Forty-four oncologists responded. They reported as barriers language problems, lack of culturally relevant cancer information, and complex protocols. Most stated that they informed Asian-American women about treatment trials. Only four women interviewed knew about trials. Other patient-identified barriers were fear of side effects, language problems, competing needs, and fear of experimentation. Family decision making was a barrier for both oncologists and patients. Compared to non-Asian oncologists, more Asian oncologists have referred Asian-American women to industry trials and identified barriers similar to patients' reports. Our findings indicate that Asian-American women need to be informed about cancer treatment trials, linguistic barriers should be addressed, and future research should evaluate cultural barriers such as family decision making.
Fernandes, Gabriel D; Alberici, Rosana M; Pereira, Gustavo G; Cabral, Elaine C; Eberlin, Marcos N; Barrera-Arellano, Daniel
2012-12-01
Commercial lecithins are composed mainly of phospholipids and triacylglycerols. The analysis of the commercial lecithins, including their fraction of phospholipids, normally involves laborious and expensive protocols. Easy ambient sonic-spray ionization mass spectrometry (EASI-MS) is shown to be an efficient technique for the analysis of lipids. Samples of commercial lecithins including standards, refined, deoiled and modified soy lecithin were tested. Characteristic profiles of phosphatidylcholines and triacylglycerols are detected by EASI(+)-MS, whereas EASI(-)-MS provided phosphatidylethanolamines, glycophospholipids and free fatty acids profiles. Acetylated lecithins also displayed characteristic acetylated derivatives. EASI-MS data was also compared to MALDI-MS, and found to display richer compositional information. The industrial process applied to lecithin fabrication was also characterised via typical EASI-MS profiles. EASI-MS both in its positive and negative ion modes offers a direct, fast and efficient technique able to characterise commercial lecithin. Copyright © 2012 Elsevier Ltd. All rights reserved.
Chip-based quantum key distribution
NASA Astrophysics Data System (ADS)
Sibson, P.; Erven, C.; Godfrey, M.; Miki, S.; Yamashita, T.; Fujiwara, M.; Sasaki, M.; Terai, H.; Tanner, M. G.; Natarajan, C. M.; Hadfield, R. H.; O'Brien, J. L.; Thompson, M. G.
2017-02-01
Improvement in secure transmission of information is an urgent need for governments, corporations and individuals. Quantum key distribution (QKD) promises security based on the laws of physics and has rapidly grown from proof-of-concept to robust demonstrations and deployment of commercial systems. Despite these advances, QKD has not been widely adopted, and large-scale deployment will likely require chip-based devices for improved performance, miniaturization and enhanced functionality. Here we report low error rate, GHz clocked QKD operation of an indium phosphide transmitter chip and a silicon oxynitride receiver chip--monolithically integrated devices using components and manufacturing processes from the telecommunications industry. We use the reconfigurability of these devices to demonstrate three prominent QKD protocols--BB84, Coherent One Way and Differential Phase Shift--with performance comparable to state-of-the-art. These devices, when combined with integrated single photon detectors, pave the way for successfully integrating QKD into future telecommunications networks.
In Vitro Mass Propagation of Cymbopogon citratus Stapf., a Medicinal Gramineae.
Quiala, Elisa; Barbón, Raúl; Capote, Alina; Pérez, Naivy; Jiménez, Elio
2016-01-01
Cymbopogon citratus (D.C.) Stapf. is a medicinal plant source of lemon grass oils with multiple uses in the pharmaceutical and food industry. Conventional propagation in semisolid culture medium has become a fast tool for mass propagation of lemon grass, but the production cost must be lower. A solution could be the application of in vitro propagation methods based on liquid culture advantages and automation. This chapter provides two efficient protocols for in vitro propagation via organogenesis and somatic embryogenesis of this medicinal plant. Firstly, we report the production of shoots using a temporary immersion system (TIS). Secondly, a protocol for somatic embryogenesis using semisolid culture for callus formation and multiplication, and liquid culture in a rotatory shaker and conventional bioreactors for the maintenance of embryogenic culture, is described. Well-developed plants can be achieved from both protocols. Here we provide a fast and efficient technology for mass propagation of this medicinal plant taking the advantage of liquid culture and automation.
Multiple Object Based RFID System Using Security Level
NASA Astrophysics Data System (ADS)
Kim, Jiyeon; Jung, Jongjin; Ryu, Ukjae; Ko, Hoon; Joe, Susan; Lee, Yongjun; Kim, Boyeon; Chang, Yunseok; Lee, Kyoonha
2007-12-01
RFID systems are increasingly applied for operational convenience in wide range of industries and individual life. However, it is uneasy for a person to control many tags because common RFID systems have the restriction that a tag used to identify just a single object. In addition, RFID systems can make some serious problems in violation of privacy and security because of their radio frequency communication. In this paper, we propose a multiple object RFID tag which can keep multiple object identifiers for different applications in a same tag. The proposed tag allows simultaneous access for their pair applications. We also propose an authentication protocol for multiple object tag to prevent serious problems of security and privacy in RFID applications. Especially, we focus on efficiency of the authentication protocol by considering security levels of applications. In the proposed protocol, the applications go through different authentication procedures according to security level of the object identifier stored in the tag. We implemented the proposed RFID scheme and made experimental results about efficiency and stability for the scheme.
Chapel, Paul
1996-01-01
The U.S. Geological Survey (USGS) is known throughout the world for conducting quality scientific investigation is hydrologic environments. Proper and consistent field techniques have been an integral part of this good research. Over the past few decades, the USGS has developed and published detailed, standard protocols for conducting studies in most aspects of the hydrologic environment. These protocols have been published in a number of diverse documents. The wealth of information contained in these diverse documents can benefit other scientists in industry, government, and academia that are involved in conducting hydrologic studies. Scientists at the USGS have brought together many of the most important of the field protocols in a user-friendly, graphical-interfaced field manual that will be useful in both the field and in the office. This electronic field manual can assist hydrologists and other scientists in conducting and documenting their field activities in a manner that is recognized standard throughout the hydrologic community.
Boehm, Markus; Wu, Tong-Ying; Claussen, Holger; Lemmen, Christian
2008-04-24
Large collections of combinatorial libraries are an integral element in today's pharmaceutical industry. It is of great interest to perform similarity searches against all virtual compounds that are synthetically accessible by any such library. Here we describe the successful application of a new software tool CoLibri on 358 combinatorial libraries based on validated reaction protocols to create a single chemistry space containing over 10 (12) possible products. Similarity searching with FTrees-FS allows the systematic exploration of this space without the need to enumerate all product structures. The search result is a set of virtual hits which are synthetically accessible by one or more of the existing reaction protocols. Grouping these virtual hits by their synthetic protocols allows the rapid design and synthesis of multiple follow-up libraries. Such library ideas support hit-to-lead design efforts for tasks like follow-up from high-throughput screening hits or scaffold hopping from one hit to another attractive series.
Pullara, Filippo; Guerrero-Santoro, Jennifer; Calero, Monica; Zhang, Qiangmin; Peng, Ye; Spåhr, Henrik; Kornberg, Guy L.; Cusimano, Antonella; Stevenson, Hilary P.; Santamaria-Suarez, Hugo; Reynolds, Shelley L.; Brown, Ian S.; Monga, Satdarshan P.S.; Van Houten, Bennett; Rapić-Otrin, Vesna; Calero, Guillermo; Levine, Arthur S.
2014-01-01
Expression of recombinant proteins in bacterial or eukaryotic systems often results in aggregation rendering them unavailable for biochemical or structural studies. Protein aggregation is a costly problem for biomedical research. It forces research laboratories and the biomedical industry to search for alternative, more soluble, non-human proteins and limits the number of potential “druggable” targets. In this study we present a highly reproducible protocol that introduces the systematic use of an extensive number of detergents to solubilize aggregated proteins expressed in bacterial and eukaryotic systems. We validate the usefulness of this protocol by solubilizing traditionally difficult human protein targets to milligram quantities and confirm their biological activity. We use this method to solubilize monomeric or multimeric components of multi-protein complexes and demonstrate its efficacy to reconstitute large cellular machines. This protocol works equally well on cytosolic, nuclear and membrane proteins and can be easily adapted to a high throughput format. PMID:23137940
Arjona, Davinia; Aragón, Carlos; Aguilera, José Antonio; Ramírez, Lucía; Pisabarro, Antonio G
2009-05-01
Fruiting is a crucial developmental process in basidiomycetes yet the genetic and molecular factors that control it are not yet fully understood. The search for fruiting inducers is of major relevance for both basic research and for their use in industrial applications. In this paper, an efficient and reproducible protocol for controlled fruiting induction of Pleurotus ostreatus growing on synthetic medium is described. The protocol is based on the control of light intensity and photoperiod and permits the life cycle for this fungus to be completed in less than two weeks. The fruiting bodies produced by this method release fertile spores after 4-5 d of culture. Our results indicate that fruiting induction is solely dependent on the illumination regime and that it occurs long before the available nutrients are depleted in the culture. This protocol will greatly facilitate molecular and developmental biology research in this fungus as it avoids the need for complex culture media based on lignocellulosic materials or the use of chemical inducers.
An Abbreviated Protocol for High-Risk Screening Breast MRI Saves Time and Resources.
Harvey, Susan C; Di Carlo, Phillip A; Lee, Bonmyong; Obadina, Eniola; Sippo, Dorothy; Mullen, Lisa
2016-04-01
To review the ability of an abbreviated, high-risk, screening, breast MRI protocol to detect cancer and save resources. High-risk screening breast MR images were reviewed, from both an abbreviated protocol and a full diagnostic protocol. Differences in cancer detection, scanner utilization, interpretation times, and need for additional imaging were recorded in an integrated data form, and reviewed and compared. A total of 568 MRI cases were reviewed, with the abbreviated and full protocols. No difference was found in the number of cancers detected. Scan times were decreased by 18.8 minutes per case, for a total of 10,678 minutes (178 hours). Interpretation time, on average, was 1.55 minutes for the abbreviated protocol, compared with 6.43 minutes for the full protocol. Review of the full protocol led to a significant change in the final BI-RADS(®) assessment in 12 of 568 (2.1%) cases. Abbreviated MRI is as effective as full-protocol MRI for demonstration of cancers in the high-risk screening setting, with only 12 (2.1%) cases recommended for additional MRI evaluation. The efficiency and resource savings of an abbreviated protocol would be significant, and would allow for opportunities to provide MRI for additional patients, as well as improved radiologist time management and workflow, with the potential to add real-time MRI interpretation or double reading. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
An Abbreviated Protocol for High-Risk Screening Breast MRI Saves Time and Resources.
Harvey, Susan C; Di Carlo, Phillip A; Lee, Bonmyong; Obadina, Eniola; Sippo, Dorothy; Mullen, Lisa
2016-11-01
To review the ability of an abbreviated, high-risk, screening, breast MRI protocol to detect cancer and save resources. High-risk screening breast MR images were reviewed, from both an abbreviated protocol and a full diagnostic protocol. Differences in cancer detection, scanner utilization, interpretation times, and need for additional imaging were recorded in an integrated data form, and reviewed and compared. A total of 568 MRI cases were reviewed, with the abbreviated and full protocols. No difference was found in the number of cancers detected. Scan times were decreased by 18.8 minutes per case, for a total of 10,678 minutes (178 hours). Interpretation time, on average, was 1.55 minutes for the abbreviated protocol, compared with 6.43 minutes for the full protocol. Review of the full protocol led to a significant change in the final BI-RADS ® assessment in 12 of 568 (2.1%) cases. Abbreviated MRI is as effective as full-protocol MRI for demonstration of cancers in the high-risk screening setting, with only 12 (2.1 %) cases recommended for additional MRI evaluation. The efficiency and resource savings of an abbreviated protocol would be significant, and would allow for opportunities to provide MRI for additional patients, as well as improved radiologist time management and workflow, with the potential to add real-time MRI interpretation or double reading. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Piek, Christine J; van Spil, Willem Evert; Junius, Greet; Dekker, Aldo
2011-04-13
Azathioprine is used as an immunosuppressant in canine immune-mediated hemolytic anemia (IMHA), but this potentially toxic and carcinogenic drug has not been proven to be beneficial. The aim of this study was to determine the difference in outcome and survival of dogs with idiopathic IMHA treated with a protocol that included azathioprine and prednisolone versus a protocol that included prednisolone alone. The study included 222 dogs with a hematocrit lower than 0.30 L/L and either a positive Coombs' test or spherocytosis and no evidence of diseases that could trigger IMHA. The clinical and laboratory data at the time of diagnosis and the response to therapy and survival were compared in dogs treated according to the prednisolone and azathioprine protocol (AP protocol; n = 149) and dogs treated according to the prednisolone protocol (P protocol; n = 73). At study entry, the two groups were comparable, except that thrombocyte counts were significantly lower and clinical signs had been present significantly longer in the AP protocol group. No significant difference in survival was found between the two groups: the 1-year survival was 64% (95% CI 54 - 77%) in the P protocol group and 69% (95% CI 59-80%) in the AP protocol group, respectively. Azathioprine would appear not to be beneficial as standard treatment for all cases of IMHA; however, a blinded, randomized clinical trial is needed to establish whether outcome is different with the two treatment protocols.
Salmen, Marcus; Ewy, Gordon A; Sasson, Comilla
2012-01-01
Objective To determine whether the use of cardiocerebral resuscitation (CCR) or AHA/ERC 2005 Resuscitation Guidelines improved patient outcomes from out-of-hospital cardiac arrest (OHCA) compared to older guidelines. Design Systematic review and meta-analysis. Data sources MEDLINE, EMBASE, Web of Science and the Cochrane Library databases. We also hand-searched study references and consulted experts. Study selection Design: randomised controlled trials and observational studies. Population OHCA patients, age >17 years. Comparators ‘Control’ protocol versus ‘Study’ protocol. ‘Control’ protocol defined as AHA/ERC 2000 Guidelines for cardiopulmonary resuscitation (CPR). ‘Study’ protocol defined as AHA/ERC 2005 Guidelines for CPR, or a CCR protocol. Outcome Survival to hospital discharge. Quality High-quality or medium-quality studies, as measured by the Newcastle Ottawa Scale using predefined categories. Results Twelve observational studies met inclusion criteria. All the three studies using CCR demonstrated significantly improved survival compared to use of AHA 2000 Guidelines, as did five of the nine studies using AHA/ERC 2005 Guidelines. Pooled data demonstrate that use of a CCR protocol has an unadjusted OR of 2.26 (95% CI 1.64 to 3.12) for survival to hospital discharge among all cardiac arrest patients. Among witnessed ventricular fibrillation/ventricular tachycardia (VF/VT) patients, CCR increased survival by an OR of 2.98 (95% CI 1.92 to 4.62). Studies using AHA/ERC 2005 Guidelines showed an overall trend towards increased survival, but significant heterogeneity existed among these studies. Conclusions We demonstrate an association with improved survival from OHCA when CCR protocols or AHA/ERC 2005 Guidelines are compared to use of older guidelines. In the subgroup of patients with witnessed VF/VT, there was a threefold increase in OHCA survival when CCR was used. CCR appears to be a promising resuscitation protocol for Emergency Medical Services providers in increasing survival from OHCA. Future research will need to be conducted to directly compare AHA/ERC 2010 Guidelines with the CCR approach. PMID:23036985
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Filing and service of papers other... Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.6 Filing and service of papers other than the...
Technical pre-analytical effects on the clinical biochemistry of Atlantic salmon (Salmo salar L.).
Braceland, M; Houston, K; Ashby, A; Matthews, C; Haining, H; Rodger, H; Eckersall, P D
2017-01-01
Clinical biochemistry has long been utilized in human and veterinary medicine as a vital diagnostic tool, but despite occasional studies showing its usefulness in monitoring health status in Atlantic salmon (Salmo salar L.), it has not yet been widely utilized within the aquaculture industry. This is due, in part, to a lack of an agreed protocol for collection and processing of blood prior to analysis. Moreover, while the analytical phase of clinical biochemistry is well controlled, there is a growing understanding that technical pre-analytical variables can influence analyte concentrations or activities. In addition, post-analytical interpretation of treatment effects is variable in the literature, thus making the true effect of sample treatment hard to evaluate. Therefore, a number of pre-analytical treatments have been investigated to examine their effect on analyte concentrations and activities. In addition, reference ranges for salmon plasma biochemical analytes have been established to inform veterinary practitioners and the aquaculture industry of the importance of clinical biochemistry in health and disease monitoring. Furthermore, a standardized protocol for blood collection has been proposed. © 2016 The Authors Journal of Fish Diseases Published by John Wiley & Sons Ltd.
Caraus, Iurie; Alsuwailem, Abdulaziz A; Nadon, Robert; Makarenkov, Vladimir
2015-11-01
Significant efforts have been made recently to improve data throughput and data quality in screening technologies related to drug design. The modern pharmaceutical industry relies heavily on high-throughput screening (HTS) and high-content screening (HCS) technologies, which include small molecule, complementary DNA (cDNA) and RNA interference (RNAi) types of screening. Data generated by these screening technologies are subject to several environmental and procedural systematic biases, which introduce errors into the hit identification process. We first review systematic biases typical of HTS and HCS screens. We highlight that study design issues and the way in which data are generated are crucial for providing unbiased screening results. Considering various data sets, including the publicly available ChemBank data, we assess the rates of systematic bias in experimental HTS by using plate-specific and assay-specific error detection tests. We describe main data normalization and correction techniques and introduce a general data preprocessing protocol. This protocol can be recommended for academic and industrial researchers involved in the analysis of current or next-generation HTS data. © The Author 2015. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
Gutiérrez-Cepeda, L; Fernández, A; Crespo, F; Gosálvez, J; Serres, C
2011-03-01
For many years in human assisted-reproduction procedures there have been special protocols to prepare and improve sperm quality. Colloidal centrifugation (CC) is a useful technique that has been proved to enhance semen quality by selection of the best spermatozoa for different species. Its use is recommended to improve fertility of subfertile stallions but current CC protocols are clinically complicated in the equine sperm processing technique due to economic and technical difficulties. The aim of this study was to determine the optimal processing procedures to adapt the use of a CC product (EquiPure™) in the equine reproduction industry. A total of nineteen ejaculates were collected from 10 Purebred Spanish Horses (P.R.E horses) using a Missouri artificial vagina. Gel-free semen aliquots were analyzed prior to treatment (control). Semen was subjected to one of six CC protocols with EquiPure™ and centrifuged samples were statistically evaluated by ANOVA and Duncan tests (p<0.05) for sperm quality and recovery rate. We obtained higher values by colloidal centrifugation in LIN, STR and BCF variables and DNA fragmentation index trended to be lower in most of the CC protocols. The studied protocols were shown to be as efficient in improving equine sperm quality as the current commercial EquiPure™, with the added advantage of being much more economical and simple to use. According to these results it seems to be possible to incorporate single layer and or high colloidal centrifugation volume protocols what would make them simple, economic and clinically viable for the equine sperm processing procedure. Copyright © 2011 Elsevier B.V. All rights reserved.
Development of wide area environment accelerator operation and diagnostics method
NASA Astrophysics Data System (ADS)
Uchiyama, Akito; Furukawa, Kazuro
2015-08-01
Remote operation and diagnostic systems for particle accelerators have been developed for beam operation and maintenance in various situations. Even though fully remote experiments are not necessary, the remote diagnosis and maintenance of the accelerator is required. Considering remote-operation operator interfaces (OPIs), the use of standard protocols such as the hypertext transfer protocol (HTTP) is advantageous, because system-dependent protocols are unnecessary between the remote client and the on-site server. Here, we have developed a client system based on WebSocket, which is a new protocol provided by the Internet Engineering Task Force for Web-based systems, as a next-generation Web-based OPI using the Experimental Physics and Industrial Control System Channel Access protocol. As a result of this implementation, WebSocket-based client systems have become available for remote operation. Also, as regards practical application, the remote operation of an accelerator via a wide area network (WAN) faces a number of challenges, e.g., the accelerator has both experimental device and radiation generator characteristics. Any error in remote control system operation could result in an immediate breakdown. Therefore, we propose the implementation of an operator intervention system for remote accelerator diagnostics and support that can obviate any differences between the local control room and remote locations. Here, remote-operation Web-based OPIs, which resolve security issues, are developed.
Bardon, Cécile; Mishara, Brian L
2015-09-01
This article presents a strategy to prevent trauma, support and care for railway personnel who experience critical incidents (CI) on the job, usually fatalities by accident or suicide. We reviewed all publications on CI management, support and care practices in the railway industry, as well as practices in place in Canada (unpublished protocols). Semi structured interviews were conducted with 40 train engineers and conductors involved in CIs and the content was coded and analysed quantitatively. Employees' satisfaction with the help received after the incident varies according to the behaviour of the local manager, company officers and police, the level of compliance with existing company protocols to help them, the presence of unmet expectations for support and care, their perceived competency of clinicians they consulted and the level of trust toward their employers. On the basis of the interview results, the review of existing railway practices and discussions with railway stakeholders, a model protocol was developed for a comprehensive workplace prevention, support and care protocol to reduce the negative impact of railway critical incidents on employees. This protocol includes preventive actions before traumatic events occur, immediate responses at the site of incident, interventions within the first few days after the incident and longer term support and interventions provided by the company and by outsourced experts.
Salmen, Marcus; Ewy, Gordon A; Sasson, Comilla
2012-01-01
To determine whether the use of cardiocerebral resuscitation (CCR) or AHA/ERC 2005 Resuscitation Guidelines improved patient outcomes from out-of-hospital cardiac arrest (OHCA) compared to older guidelines. Systematic review and meta-analysis. MEDLINE, EMBASE, Web of Science and the Cochrane Library databases. We also hand-searched study references and consulted experts. Design: randomised controlled trials and observational studies. OHCA patients, age >17 years. 'Control' protocol versus 'Study' protocol. 'Control' protocol defined as AHA/ERC 2000 Guidelines for cardiopulmonary resuscitation (CPR). 'Study' protocol defined as AHA/ERC 2005 Guidelines for CPR, or a CCR protocol. Survival to hospital discharge. High-quality or medium-quality studies, as measured by the Newcastle Ottawa Scale using predefined categories. Twelve observational studies met inclusion criteria. All the three studies using CCR demonstrated significantly improved survival compared to use of AHA 2000 Guidelines, as did five of the nine studies using AHA/ERC 2005 Guidelines. Pooled data demonstrate that use of a CCR protocol has an unadjusted OR of 2.26 (95% CI 1.64 to 3.12) for survival to hospital discharge among all cardiac arrest patients. Among witnessed ventricular fibrillation/ventricular tachycardia (VF/VT) patients, CCR increased survival by an OR of 2.98 (95% CI 1.92 to 4.62). Studies using AHA/ERC 2005 Guidelines showed an overall trend towards increased survival, but significant heterogeneity existed among these studies. We demonstrate an association with improved survival from OHCA when CCR protocols or AHA/ERC 2005 Guidelines are compared to use of older guidelines. In the subgroup of patients with witnessed VF/VT, there was a threefold increase in OHCA survival when CCR was used. CCR appears to be a promising resuscitation protocol for Emergency Medical Services providers in increasing survival from OHCA. Future research will need to be conducted to directly compare AHA/ERC 2010 Guidelines with the CCR approach.
Aissa, Joel; Boos, Johannes; Rubbert, Christian; Caspers, Julian; Schleich, Christoph; Thomas, Christoph; Kröpil, Patric; Antoch, Gerald; Miese, Falk
2017-06-01
The aim of this study was to evaluate the objective and subjective image quality of a novel computed tomography (CT) protocol with reduced radiation dose for body packing with 80 kVp and automated tube current modulation (ATCM) compared to a standard body packing CT protocol. 80 individuals who were examined between March 2012 and July 2015 in suspicion of ingested drug packets were retrospectively included in this study. Thirty-one CT examinations were performed using ATCM and a fixed tube voltage of 80 kVp (group A). Forty-nine CT examinations were performed using a standard protocol with a tube voltage of 120 kVp and a fixed tube current time product of 40 mAs (group B). Subjective and objective image quality and visibility of drug packets were assessed. Radiation exposure of both protocols was compared. Contrast-to-noise ratio (group A: 0.56 ± 0.36; group B: 1.13 ± 0.91) and Signal-to-noise ratio (group A: 3.69 ± 0.98; group B: 7.08 ± 2.67) were significantly lower for group A compared to group B (p < 0.001). Subjectively, image quality was decreased for group A compared to group B (2.5 ± 0.8 vs. 1.2 ± 0.4; p < 0.001). Attenuation of body packets was higher with the new protocol (group A: 362.2 ± 70.3 Hounsfield Units (HU); group B: 210.6 ± 60.2 HU; p = 0.005). Volumetric Computed Tomography Dose Index (CTDIvol) and Dose Length Product (DLP) were significantly lower in group A (CTDIvol 2.2 ± 0.9 mGy, DLP 105.7 ± 52.3 mGycm) as compared to group B (CTDIvol 2.7 ± 0.1 mGy, DLP 126.0 ± 9.7 mGycm, p = 0.002 and p = 0.01). The novel 80 kVp CT protocol with ATCM leads to a significant dose reduction compared to a standard CT body packing protocol. The novel protocol led to a diagnostic image quality and cocaine body packets were reliably detected due to the high attenuation.
Comparison of inter-trial recovery times for the determination of critical power and W' in cycling.
Karsten, Bettina; Hopker, James; Jobson, Simon A; Baker, Jonathan; Petrigna, Luca; Klose, Andreas; Beedie, Christopher
2017-07-01
Critical Power (CP) and W' are often determined using multi-day testing protocols. To investigate this cumbersome testing method, the purpose of this study was to compare the differences between the conventional use of a 24-h inter-trial recovery time with those of 3 h and 30 min for the determination of CP and W'. 9 moderately trained cyclists performed an incremental test to exhaustion to establish the power output associated with the maximum oxygen uptake (p[Formula: see text] max ), and 3 protocols requiring time-to-exhaustion trials at a constant work-rate performed at 80%, 100% and 105% of p[Formula: see text] max. Design: Protocol A utilised 24-h inter-trial recovery (CP 24 /W' 24 ), protocol B utilised 3-h inter-trial recovery (CP 3 /W' 3 ), and protocol C used 30-min inter-trial recovery period (CP 0.5 /W' 0.5 ). CP and W' were calculated using the inverse time (1/t) versus power (P) relation (P = W'(1/t) + CP). 95% Limits of Agreement between protocol A and B were -9 to 15 W; -7.4 to 7.8 kJ (CP/W') and between protocol A and protocol C they were -27 to 22 W; -7.2 to 15.1 kJ (CP/W'). Compared to criterion protocol A, the average prediction error of protocol B was 2.5% (CP) and 25.6% (W'), whilst for protocol C it was 3.7% (CP) and 32.9% (W'). 3-h and 30-min inter-trial recovery time protocols provide valid methods of determining CP but not W' in cycling.
Vassalou, Evangelia E; Raissaki, Maria; Magkanas, Eleftherios; Antoniou, Katerina M; Karantanas, Apostolos H
2017-12-01
To compare lung ultrasonography (US) in the sitting or supine positions and the lateral decubitus position, with regard to the feasibility, duration, patient convenience, and assessment of B-lines, in patients with idiopathic pulmonary fibrosis. Twenty consecutive patients with idiopathic pulmonary fibrosis were prospectively enrolled. Lung US included scanning of 56 intercostal spaces. Each patient was examined twice by 2 protocols. During protocol 1, patients were examined in the supine and sitting positions for the anterior and dorsal chest, respectively. During protocol 2, patients were examined in the left lateral decubitus position for the evaluation of the right hemithorax and the reverse. Total, anterior, and posterior US scores resulted from the sum of B-lines at the whole, anterior, and posterior chest, respectively. High-resolution computed tomography (CT) was considered the reference standard. The duration of each protocol was recorded. Patients were questioned about which protocol they preferred. There was no difference regarding feasibility between the protocols. A significant correlation was found between total US scores for both protocols and high-resolution CT findings (P < .0001), with protocol 2 showing a slightly higher correlation. A positive correlation was found between the protocols regarding total, anterior, and posterior US scores (P < .0001). The mean duration of protocol 2 was less than that of protocol 1 (P < .005). Nineteen patients (95%) reported a preference for protocol 2. Lung US in the lateral decubitus position seems to be faster and more convenient. There appears to be no difference regarding feasibility and the number of B-lines, whereas it shows slightly higher correlation with high-resolution CT, compared with the sitting or supine positions in patients with idiopathic pulmonary fibrosis. © 2017 by the American Institute of Ultrasound in Medicine.
Riber-Hansen, Rikke; Hastrup, Nina; Clemmensen, Ole; Behrendt, Nille; Klausen, Siri; Ramsing, Mette; Spaun, Eva; Hamilton-Dutoit, Stephen Jacques; Steiniche, Torben
2012-02-01
Metastasis size in melanoma sentinel lymph nodes (SLNs) is an emerging prognostic factor. Two European melanoma treatment trials include SLN metastasis diameters as inclusion criteria. Whilst diameter estimates are sensitive to the number of sections examined, the level of this bias is largely unknown. We performed a prospective multicentre study to compare the European Organisation for Research and Treatment of Cancer (EORTC) recommended protocol with a protocol of complete step-sectioning. One hundred and thirty-three consecutive SLNs from seven SLN centres were analysed by five central sections 50μm apart (EORTC Protocol) followed by complete 250μm step-sectioning. Overall, 29 patients (21.8%) were SLN-positive. The EORTC Protocol missed eight of these metastases (28%), one metastasis measuring less than 0.1mm in diameter, seven measuring between 0.1 and 1mm. Complete step-sectioning at 250μm intervals (Extensive Protocol) missed one metastasis (3%) that measured less than 0.1mm. Thirteen treatment courses (34%) performed if inclusion was based on the Combined Protocol would not be performed if assessed by the EORTC Protocol. Thus, 10 patients would be without completion lymph node dissection (EORTC MINITUB study), whilst three patients would not be eligible for anti-CTLA4 trial (EORTC protocol 18071). The corresponding number with the Extensive Protocol would be three; one patient for the MINITUB registration study and two patients for the anti-CTLA4 study. Examining SLNs by close central sectioning alone (EORTC Protocol) misses a substantial number of metastases and underestimates the maximum metastasis diameter, leading to important changes in patient eligibility for various treatment protocols. Copyright © 2011 Elsevier Ltd. All rights reserved.
Rassnick, K M; Bailey, D B; Malone, E K; Intile, J L; Kiselow, M A; Flory, A B; Barlow, L L; Balkman, C E; Barnard, S M; Waite, A H
2010-12-01
An L-CHOP protocol with interposed treatments of CCNU and MOPP (L-CHOP-CCNU-MOPP) was evaluated in 66 dogs with stages III-V lymphoma. Results were compared with a historical group of 71 dogs treated with an L-CHOP protocol. Complete remission (CR) rates (85 and 80%, respectively) did not differ significantly between protocols (P = 0.48). First CR duration for dogs treated with L-CHOP-CCNU-MOPP was significantly longer: median, 317 days; 2-year CR rate, 35% versus median, 298 days; 2-year CR rate, 13%, P = 0.05). For the L-CHOP-CCNU-MOPP protocol, dogs in substage-b had a 4.3 times greater hazard of having a relapse than dogs in substage-a (P = 0.002). Frequency of adverse chemotherapy-associated gastrointestinal effects did not differ between protocols (P = 0.77). Neutropenia (primarily after CCNU) occurred more frequently in dogs treated with L-CHOP-CCNU-MOPP (P < 0.001). In summary, the L-CHOP-CCNU-MOPP protocol showed an improved duration of first CR as compared with an L-CHOP protocol, but the relevance of this finding might be subject to clinical judgement. © 2010 Blackwell Publishing Ltd.
Xu, Jian; Kim, Daniel; Otazo, Ricardo; Srichai, Monvadi B; Lim, Ruth P; Axel, Leon; Mcgorty, Kelly Anne; Niendorf, Thoralf; Sodickson, Daniel K
2013-07-01
To evaluate the feasibility and perform initial comparative evaluations of a 5-minute comprehensive whole-heart magnetic resonance imaging (MRI) protocol with four image acquisition types: perfusion (PERF), function (CINE), coronary artery imaging (CAI), and late gadolinium enhancement (LGE). This study protocol was Health Insurance Portability and Accountability Act (HIPAA)-compliant and Institutional Review Board-approved. A 5-minute comprehensive whole-heart MRI examination protocol (Accelerated) using 6-8-fold-accelerated volumetric parallel imaging was incorporated into and compared with a standard 2D clinical routine protocol (Standard). Following informed consent, 20 patients were imaged with both protocols. Datasets were reviewed for image quality using a 5-point Likert scale (0 = non-diagnostic, 4 = excellent) in blinded fashion by two readers. Good image quality with full whole-heart coverage was achieved using the accelerated protocol, particularly for CAI, although significant degradations in quality, as compared with traditional lengthy examinations, were observed for the other image types. Mean total scan time was significantly lower for the Accelerated as compared to Standard protocols (28.99 ± 4.59 min vs. 1.82 ± 0.05 min, P < 0.05). Overall image quality for the Standard vs. Accelerated protocol was 3.67 ± 0.29 vs. 1.5 ± 0.51 (P < 0.005) for PERF, 3.48 ± 0.64 vs. 2.6 ± 0.68 (P < 0.005) for CINE, 2.35 ± 1.01 vs. 2.48 ± 0.68 (P = 0.75) for CAI, and 3.67 ± 0.42 vs. 2.67 ± 0.84 (P < 0.005) for LGE. Diagnostic image quality for Standard vs. Accelerated protocols was 20/20 (100%) vs. 10/20 (50%) for PERF, 20/20 (100%) vs. 18/20 (90%) for CINE, 18/20 (90%) vs. 18/20 (90%) for CAI, and 20/20 (100%) vs. 18/20 (90%) for LGE. This study demonstrates the technical feasibility and promising image quality of 5-minute comprehensive whole-heart cardiac examinations, with simplified scan prescription and high spatial and temporal resolution enabled by highly parallel imaging technology. The study also highlights technical hurdles that remain to be addressed. Although image quality remained diagnostic for most scan types, the reduced image quality of PERF, CINE, and LGE scans in the Accelerated protocol remain a concern. Copyright © 2012 Wiley Periodicals, Inc.
This handbook contains protocols that compare the immediate performance of subslab depressurization (SSD) mitigation system with performance months or years later. These protocols provide a methodology to test SSD radon mitigation systems in situ to determine long-term performanc...
Mergenthal, Michelle C; Senapati, Suneeta; Zee, Jarcy; Allen-Taylor, Lynne; Whittaker, Paul G; Takacs, Peter; Sammel, Mary D; Barnhart, Kurt T
2016-11-01
Ectopic pregnancy, although rare, is an important cause of female morbidity and mortality and early, effective treatment is critical. Systemic methotrexate has become widely accepted as a safe and effective alternative to surgery in the stable patient. As the number and timing of methotrexate doses differ in the 3 main medical treatment regimens, one might expect trends in serum human chorionic gonadotropin and time to resolution to vary depending on protocol. Furthermore, human chorionic gonadotropin trends and time to resolution may predict ultimate treatment success. This study hypothesized that the 2-dose methotrexate protocol would be associated with a faster initial decline in serum human chorionic gonadotropin levels and a shorter time to resolution compared to the single-dose protocol. A prospective multicenter cohort study included clinical data from women who received medical management for ectopic pregnancy. Rates of human chorionic gonadotropin change and successful pregnancy resolution were assessed. Propensity score modeling addressed confounding by indication, the potential for differential assignment of patients with better prognosis to the single-dose methotrexate protocol. In all, 162 ectopic pregnancies were in the final analysis; 114 (70%) were treated with the single-dose methotrexate and 48 (30%) with the 2-dose protocol. Site, race, ethnicity, and reported pain level were associated with differential protocol allocation (P < .001, P = .011, P < .001, and P = .035, respectively). Women had similar initial human chorionic gonadotropin levels in either protocol but the mean rate of decline of human chorionic gonadotropin from day 0 (day of administration of first dose of methotrexate) to day 7 was significantly more rapid in women who received the single-dose protocol compared to those treated with the 2-dose protocol (mean change -31.3% vs -10.4%, P = .037, adjusted for propensity score and site). The 2 protocols had no significant differences in success rate or time to resolution. In a racially and geographically diverse group of women, the single- and double-dose methotrexate protocols had comparable outcomes. The more rapid human chorionic gonadotropin initial decline in the single-dose group suggested these patients were probably at lower risk for ectopic rupture than those getting the 2-dose protocol. A prospective randomized controlled design is needed to remove confounding by indication. Copyright © 2016 Elsevier Inc. All rights reserved.
Kasparek, Maximilian F; Töpker, Michael; Lazar, Mathias; Weber, Michael; Kasparek, Michael; Mang, Thomas; Apfaltrer, Paul; Kubista, Bernd; Windhager, Reinhard; Ringl, Helmut
2018-06-07
To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p < 0.001). Dual-energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p < 0.001). All dual-energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface. These findings support the use of dual-energy CT as a solid imaging base for clinical decision-making and the use of full-titanium or ceramic prostheses to allow for better CT visualization of the bone-prosthesis interface.
Verhegghe, M; Rasschaert, G; Herman, L; Goossens, K; Vandaele, L; De Bleecker, K; Vlaemynck, G; Heyndrickx, M; De Block, J
2017-05-01
The aim of this study was to develop and validate 2 protocols (for use on-farm and at a central location) for the reduction of Mycobacterium avium ssp. paratuberculosis (MAP) in colostrum while preserving beneficial immunoglobulins (IgG). The on-farm protocol was based on curdling of the colostrum, where the IgG remain in the whey and the MAP bacteria are trapped in the curd. First, the colostrum was diluted with water (2 volumes colostrum to 1 volume water) and 2% rennet was added. After incubation (1 h at 32°C), the curd was cut and incubated again, after which whey and curd were separated using a cheesecloth. The curd was removed and milk powder was added to the whey. Approximately 1 log reduction in MAP counts was achieved. A reduction in total proteins and IgG was observed due to initial dilution of the colostrum. After curd formation, more than 95% of the immunoglobulins remained in the whey fraction. The semi-industrial protocol was based on centrifugation, which causes MAP to precipitate, while the IgG remain in the supernatant. This protocol was first developed in the laboratory. The colostrum was diluted with skimmed colostrum (2 volumes colostrum to 1 volume skimmed colostrum), then skimmed and centrifuged (at 15,600 × g for 30 min at room temperature). We observed on average 1.5 log reduction in the MAP counts and a limited reduction in proteins and IgG in the supernatant. To obtain a semi-industrial protocol, dairy pilot appliances were evaluated and the following changes were applied to the protocol: after 2:1 dilution as above, the colostrum was skimmed and subsequently clarified, after which the cream was heat treated and added to the supernatant. To investigate the effect of the colostrum treatment on the nutritional value and palatability of the colostrum and the IgG transfer, an animal experiment was conducted with 24 calves. Six received the dam's colostrum, 6 were given untreated purchased colostrum (control), and 2 groups of 6 calves received colostrum treated according to both of the above-mentioned methods. No significant differences were found between the test groups and the dam's colostrum group in terms of animal health, IgG uptake in the blood serum, milk, or forage uptake. Two protocols to reduce MAP in colostrum (for use on-farm or at a central location) were developed. Both methods preserve the vital IgG. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Sakata, K.; Tagomori, K.; Sugiyama, N.; Sasaki, S.; Shinya, Y.; Nanbu, T.; Kawashita, Y.; Narita, I.; Kuwatori, K.; Ikeda, T.; Hara, R.; Miyahara, H.
2014-01-01
Compared to conventional thermal spray coating, cold spray processing typically employs finer, smaller-diameter metal powders. Furthermore, cold-sprayed particles exhibit fewer surface oxides than thermally sprayed particles due to the absence of particle melting during spraying. For these reasons, it is important to consider the potential for dust explosions or fires during cold spray processing, for both industrial and R&D applications. This work examined the dust explosion characteristics of metal powders typically used in cold spray coating, for the purpose of preventing dust explosions and fires and thus protecting the health and safety of workers and guarding against property damage. In order to safely make use of the new cold spray technology in industrial settings, it is necessary to manage the risks based on an appropriate assessment of the hazards. However, there have been few research reports focused on such risk management. Therefore, in this study, the dust explosion characteristics of aluminum, titanium, zinc, carbonyl iron, and eutectoid steel containing chromium at 4 wt.% (4 wt.% Cr-eutectoid steel) powders were evaluated according to the standard protocols JIS Z 8818, IEC61241-2-3(1994-09) section 3, and JIS Z 8817. This paper reports our results concerning the dust explosion properties of the above-mentioned metal powders.
Orphan drug: Development trends and strategies
Sharma, Aarti; Jacob, Abraham; Tandon, Manas; Kumar, Dushyant
2010-01-01
The growth of pharma industries has slowed in recent years because of various reasons such as patent expiries, generic competition, drying pipelines, and increasingly stringent regulatory guidelines. Many blockbuster drugs will loose their exclusivity in next 5 years. Therefore, the current economic situation plus the huge generic competition shifted the focus of pharmaceutical companies from the essential medicines to the new business model — niche busters, also called orphan drugs. Orphan drugs may help pharma companies to reduce the impact of revenue loss caused by patent expiries of blockbuster drugs. The new business model of orphan drugs could offer an integrated healthcare solution that enables pharma companies to develop newer areas of therapeutics, diagnosis, treatment, monitoring, and patient support. Incentives for drug development provided by governments, as well as support from the FDA and EU Commission in special protocols, are a further boost for the companies developing orphan drugs. Although there may still be challenges ahead for the pharmaceutical industry, orphan drugs seem to offer the key to recovery and stability within the market. In our study, we have compared the policies and orphan drug incentives worldwide alongwith the challenges faced by the pharmaceutical companies. Recent developments are seen in orphan drug approval, the various drugs in orphan drug pipeline, and the future prospectives for orphan drugs and diseases. PMID:21180460
Engineered yeast for enhanced CO2 mineralization†
Barbero, Roberto; Carnelli, Lino; Simon, Anna; Kao, Albert; Monforte, Alessandra d’Arminio; Riccò, Moreno; Bianchi, Daniele; Belcher, Angela
2014-01-01
In this work, a biologically catalyzed CO2 mineralization process for the capture of CO2 from point sources was designed, constructed at a laboratory scale, and, using standard chemical process scale-up protocols, was modeled and evaluated at an industrial scale. A yeast display system in Saccharomyces cerevisae was used to screen several carbonic anhydrase isoforms and mineralization peptides for their impact on CO2 hydration, CaCO3 mineralization, and particle settling rate. Enhanced rates for each of these steps in the CaCO3 mineralization process were confirmed using quantitative techniques in lab-scale measurements. The effect of these enhanced rates on the CO2 capture cost in an industrial scale CO2 mineralization process using coal fly ash as the CaO source was evaluated. The model predicts a process using bCA2- yeast and fly ash is ~10% more cost effective per ton of CO2 captured than a process with no biological molecules, a savings not realized by wild-type yeast and high-temperature stable recombinant CA2 alone or in combination. The levelized cost of electricity for a power plant using this process was calculated and scenarios in which this process compares favorably to CO2 capture by MEA absorption process are presented. PMID:25289021
Fernández-Gutiérrez, Fabiola; Martínez, Santiago; Rube, Martin A; Cox, Benjamin F; Fatahi, Mahsa; Scott-Brown, Kenneth C; Houston, J Graeme; McLeod, Helen; White, Richard D; French, Karen; Gueorguieva, Mariana; Immel, Erwin; Melzer, Andreas
2015-10-01
A methodological framework is introduced to assess and compare a conventional fluoroscopy protocol for peripheral angioplasty with a new magnetic resonant imaging (MRI)-guided protocol. Different scenarios were considered during interventions on a perfused arterial phantom with regard to time-based and cognitive task analysis, user experience and ergonomics. Three clinicians with different expertise performed a total of 43 simulated common iliac angioplasties (9 fluoroscopic, 34 MRI-guided) in two blocks of sessions. Six different configurations for MRI guidance were tested in the first block. Four of them were evaluated in the second block and compared to the fluoroscopy protocol. Relevant stages' durations were collected, and interventions were audio-visually recorded from different perspectives. A cued retrospective protocol analysis (CRPA) was undertaken, including personal interviews. In addition, ergonomic constraints in the MRI suite were evaluated. Significant differences were found when comparing the performance between MRI configurations versus fluoroscopy. Two configurations [with times of 8.56 (0.64) and 9.48 (1.13) min] led to reduce procedure time for MRI guidance, comparable to fluoroscopy [8.49 (0.75) min]. The CRPA pointed out the main influential factors for clinical procedure performance. The ergonomic analysis quantified musculoskeletal risks for interventional radiologists when utilising MRI. Several alternatives were suggested to prevent potential low-back injuries. This work presents a step towards the implementation of efficient operational protocols for MRI-guided procedures based on an integral and multidisciplinary framework, applicable to the assessment of current vascular protocols. The use of first-user perspective raises the possibility of establishing new forms of clinical training and education.
Detection of Banned and Restricted Ozone-Depleting Chemicals in Printed Circuit Boards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Richard N.; Wright, Bob W.
2008-12-01
A study directed toward the detection of halogenated solvents in the matrix of circuit boards has recently been completed. This work was undertaken to demonstrate the potential for reliable detection of solvents used during the fabrication of printed circuit boards (PCB). Since many of these solvents are now, or soon will be, restricted under the terms of legislation enacted in response to the Montreal Protocol and other international agreements, the work described here, conducted over a period of more that 4 years, has provided guidance for the development of chromatographic system and analytical protocol to assure compliance with regulations introducedmore » to control, or ban, industrial solvents associated with adverse environmental impact.« less
Software-defined Radio Based Measurement Platform for Wireless Networks
Chao, I-Chun; Lee, Kang B.; Candell, Richard; Proctor, Frederick; Shen, Chien-Chung; Lin, Shinn-Yan
2015-01-01
End-to-end latency is critical to many distributed applications and services that are based on computer networks. There has been a dramatic push to adopt wireless networking technologies and protocols (such as WiFi, ZigBee, WirelessHART, Bluetooth, ISA100.11a, etc.) into time-critical applications. Examples of such applications include industrial automation, telecommunications, power utility, and financial services. While performance measurement of wired networks has been extensively studied, measuring and quantifying the performance of wireless networks face new challenges and demand different approaches and techniques. In this paper, we describe the design of a measurement platform based on the technologies of software-defined radio (SDR) and IEEE 1588 Precision Time Protocol (PTP) for evaluating the performance of wireless networks. PMID:27891210
Software-defined Radio Based Measurement Platform for Wireless Networks.
Chao, I-Chun; Lee, Kang B; Candell, Richard; Proctor, Frederick; Shen, Chien-Chung; Lin, Shinn-Yan
2015-10-01
End-to-end latency is critical to many distributed applications and services that are based on computer networks. There has been a dramatic push to adopt wireless networking technologies and protocols (such as WiFi, ZigBee, WirelessHART, Bluetooth, ISA100.11a, etc. ) into time-critical applications. Examples of such applications include industrial automation, telecommunications, power utility, and financial services. While performance measurement of wired networks has been extensively studied, measuring and quantifying the performance of wireless networks face new challenges and demand different approaches and techniques. In this paper, we describe the design of a measurement platform based on the technologies of software-defined radio (SDR) and IEEE 1588 Precision Time Protocol (PTP) for evaluating the performance of wireless networks.
Serra, M; Pereiro, I; Yamada, A; Viovy, J-L; Descroix, S; Ferraro, D
2017-02-14
The sealing of microfluidic devices remains a complex and time-consuming process requiring specific equipment and protocols: a universal method is thus highly desirable. We propose here the use of a commercially available sealing tape as a robust, versatile, reversible solution, compatible with cell and molecular biology protocols, and requiring only the application of manually achievable pressures. The performance of the seal was tested with regards to the most commonly used chip materials. For most materials, the bonding resisted 5 bars at room temperature and 1 bar at 95 °C. This method should find numerous uses, ranging from fast prototyping in the laboratory to implementation in low technology environments or industrial production.
Wong, Anthony F; Pielmeier, Ulrike; Haug, Peter J; Andreassen, Steen
2016-01-01
Objective Develop an efficient non-clinical method for identifying promising computer-based protocols for clinical study. An in silico comparison can provide information that informs the decision to proceed to a clinical trial. The authors compared two existing computer-based insulin infusion protocols: eProtocol-insulin from Utah, USA, and Glucosafe from Denmark. Materials and Methods The authors used eProtocol-insulin to manage intensive care unit (ICU) hyperglycemia with intravenous (IV) insulin from 2004 to 2010. Recommendations accepted by the bedside clinicians directly link the subsequent blood glucose values to eProtocol-insulin recommendations and provide a unique clinical database. The authors retrospectively compared in silico 18 984 eProtocol-insulin continuous IV insulin infusion rate recommendations from 408 ICU patients with those of Glucosafe, the candidate computer-based protocol. The subsequent blood glucose measurement value (low, on target, high) was used to identify if the insulin recommendation was too high, on target, or too low. Results Glucosafe consistently provided more favorable continuous IV insulin infusion rate recommendations than eProtocol-insulin for on target (64% of comparisons), low (80% of comparisons), or high (70% of comparisons) blood glucose. Aggregated eProtocol-insulin and Glucosafe continuous IV insulin infusion rates were clinically similar though statistically significantly different (Wilcoxon signed rank test P = .01). In contrast, when stratified by low, on target, or high subsequent blood glucose measurement, insulin infusion rates from eProtocol-insulin and Glucosafe were statistically significantly different (Wilcoxon signed rank test, P < .001), and clinically different. Discussion This in silico comparison appears to be an efficient nonclinical method for identifying promising computer-based protocols. Conclusion Preclinical in silico comparison analytical framework allows rapid and inexpensive identification of computer-based protocol care strategies that justify expensive and burdensome clinical trials. PMID:26228765
One Step Quantum Key Distribution Based on EPR Entanglement.
Li, Jian; Li, Na; Li, Lei-Lei; Wang, Tao
2016-06-30
A novel quantum key distribution protocol is presented, based on entanglement and dense coding and allowing asymptotically secure key distribution. Considering the storage time limit of quantum bits, a grouping quantum key distribution protocol is proposed, which overcomes the vulnerability of first protocol and improves the maneuverability. Moreover, a security analysis is given and a simple type of eavesdropper's attack would introduce at least an error rate of 46.875%. Compared with the "Ping-pong" protocol involving two steps, the proposed protocol does not need to store the qubit and only involves one step.
Enabling Secure XMPP Communications in Federated IoT Clouds Through XEP 0027 and SAML/SASL SSO
Celesti, Antonio; Fazio, Maria; Villari, Massimo
2017-01-01
Nowadays, in the panorama of Internet of Things (IoT), finding a right compromise between interactivity and security is not trivial at all. Currently, most of pervasive communication technologies are designed to work locally. As a consequence, the development of large-scale Internet services and applications is not so easy for IoT Cloud providers. The main issue is that both IoT architectures and services have started as simple but they are becoming more and more complex. Consequently, the web service technology is often inappropriate. Recently, many operators in both academia and industry fields are considering the possibility to adopt the eXtensible Messaging and Presence Protocol (XMPP) for the implementation of IoT Cloud communication systems. In fact, XMPP offers many advantages in term of real-time capabilities, efficient data distribution, service discovery and inter-domain communication compared to other technologies. Nevertheless, the protocol lacks of native security, data confidentiality and trustworthy federation features. In this paper, considering an XMPP-based IoT Cloud architectural model, we discuss how can be possible to enforce message signing/encryption and Single-Sign On (SSO) authentication respectively for secure inter-module and inter-domain communications in a federated environment. Experiments prove that security mechanisms introduce an acceptable overhead, considering the obvious advantages achieved in terms of data trustiness and privacy. PMID:28178214
Enabling Secure XMPP Communications in Federated IoT Clouds Through XEP 0027 and SAML/SASL SSO.
Celesti, Antonio; Fazio, Maria; Villari, Massimo
2017-02-07
Nowadays, in the panorama of Internet of Things (IoT), finding a right compromise between interactivity and security is not trivial at all. Currently, most of pervasive communication technologies are designed to work locally. As a consequence, the development of large-scale Internet services and applications is not so easy for IoT Cloud providers. The main issue is that both IoT architectures and services have started as simple but they are becoming more and more complex. Consequently, the web service technology is often inappropriate. Recently, many operators in both academia and industry fields are considering the possibility to adopt the eXtensible Messaging and Presence Protocol (XMPP) for the implementation of IoT Cloud communication systems. In fact, XMPP offers many advantages in term of real-time capabilities, efficient data distribution, service discovery and inter-domain communication compared to other technologies. Nevertheless, the protocol lacks of native security, data confidentiality and trustworthy federation features. In this paper, considering an XMPP-based IoT Cloud architectural model, we discuss how can be possible to enforce message signing/encryption and Single-Sign On (SSO) authentication respectively for secure inter-module and inter-domain communications in a federated environment. Experiments prove that security mechanisms introduce an acceptable overhead, considering the obvious advantages achieved in terms of data trustiness and privacy.
Perlmutter, A S; Tran, V-T; Dechartres, A; Ravaud, P
2017-04-01
Protocols are often unavailable to peer-reviewers and readers. To detect outcome reporting bias (ORB), readers usually have to resort to publicly available descriptions of study design such as public clinical trial registries. We compared primary outcomes in protocols, ClinicalTrials.gov and publications of oncology trials and evaluated the use of ClinicalTrials.gov as compared with protocols in detecting discrepancies between planned and published outcomes. We searched for phase III oncology trials registered in ClinicalTrials.gov and published in the Journal of Clinical Oncology and New England Journal of Medicine between January 2014 and June 2015. We extracted primary outcomes reported in the protocol, ClinicalTrials.gov and the publication. First, we assessed the quality of primary outcome descriptions by using a published framework. Second, we evaluated modifications of primary outcomes between each source. Finally, we evaluated the agreement, specificity and sensitivity of detecting modifications between planned and published outcomes by using protocols or ClinicalTrials.gov. We included 65 trials, with 81 primary outcomes common among the 3 sources. The proportion of primary outcomes reporting all items from the framework was 73%, 22%, and 75% for protocols, ClinicalTrials.gov and publications, respectively. Eight (12%) trials presented a discrepancy between primary outcomes reported in the protocol and in the publication. Twelve (18.5%) trials presented a discrepancy between primary outcomes registered at ClinicalTrials.gov and in publications. We found a moderate agreement in detecting discrepant reporting of outcomes by using protocols or ClinicalTrials.gov [κ = 0.53, 95% confidence interval (0.25-0.81)]. Using ClinicalTrials.gov to detect discrepant reporting of outcomes showed high specificity (89.5%) but lacked sensitivity (75%) as compared with use of protocols. In oncology trials, primary outcome descriptions in ClinicalTrials.gov are often of low quality and may not reflect what is in the protocol, thus limiting the detection of modifications between planned and published outcomes. © The Author 2016. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Satellite-Friendly Protocols and Standards
NASA Astrophysics Data System (ADS)
Koudelka, O.; Schmidt, M.; Ebert, J.; Schlemmer, H.; Kastner, S.; Riedler, W.
2002-01-01
We are currently observing a development unprecedented with other services, the enormous growth of the Internet. Video, voice and data applications can be supported via this network in high quality. Multi-media applications require high bandwidth which may not be available in many areas. When making proper use of the broadcast feature of a communications satellite, the performance of the satellite-based system can compare favourably to terrestrial solutions. Internet applications are in many cases highly asymmetric, making them very well suited to applications using small and inexpensive terminals. Data from one source may be used simultaneously by a large number of users. The Internet protocol suite has become the de-facto standard. But this protocol family in its original form has not been designed to support guaranteed quality of service, a prerequisite for real-time, high quality traffic. The Internet Protocol has to be adapted for the satellite environment, because long roundtrip delays and the error behaviour of the channel could make it inefficient over a GEO satellite. Another requirement is to utilise the satellite bandwidth as efficiently as possible. This can be achieved by adapting the access system to the nature of IP frames, which are variable in length. In the framework of ESA's ARTES project a novel satellite multimedia system was developed which utilises Multi-Frequency TDMA in a meshed network topology. The system supports Quality of Service (QoS) by reserving capacity with different QoS requirements. The system is centrally controlled by a master station with the implementation of a demand assignment (DAMA) system. A lean internal signalling system has been adopted. Network management is based on the SNMP protocol and industry-standard network management platforms, making interfaces to standard accounting and billing systems easy. Modern communication systems will have to be compliant to different standards in a very flexible manner. The developed system is based on a hardware architecture using FPGAs (Field-Programmable Gate Arrays). This provides means to configure the satellite gateway for different standards and to optimise the transmission parameters for varying user traffic, thus increasing the efficiency significantly. The paper describes the flexible system architecture and focuses particularly on the DAMA access scheme and the chosen quality-of-service implementation. Emphasis has been put on the support of IP Version 6. Different standards (e.g. RCS and possible follow-ups) and the possibility to support them are discussed.
Santos, E M; Paula, J F R; Motta, P M C; Heinemann, M B; Leite, R C; Haddad, J P A; Del Puerto, H L; Reis, J K P
2010-08-17
We compared three different protocols for DNA extraction from horse peripheral blood mononuclear cells (PBMC) and lung fragments, determining average final DNA concentration, purity, percentage of PCR amplification using beta-actin, and cost. Thirty-four samples from PBMC, and 33 samples from lung fragments were submitted to DNA extraction by three different protocols. Protocol A consisted of a phenol-chloroform and isoamylic alcohol extraction, Protocol B used alkaline extraction with NaOH, and Protocol C used the DNAzol((R)) reagent kit. Protocol A was the best option for DNA extraction from lung fragments, producing high DNA concentrations, with high sensitivity in PCR amplification (100%), followed by Protocols C and B. On the other hand, for PBMC samples, Protocol B gave the highest sensitivity in PCR amplification (100%), followed by Protocols C and A. We conclude that Protocol A should be used for PCR diagnosis from lung fragment samples, while Protocol B should be used for PBMC.
NASA Astrophysics Data System (ADS)
Graziosi, F.; Arduini, J.; Furlani, F.; Giostra, U.; Cristofanelli, P.; Fang, X.; Hermanssen, O.; Lunder, C.; Maenhout, G.; O'Doherty, S.; Reimann, S.; Schmidbauer, N.; Vollmer, M. K.; Young, D.; Maione, M.
2017-06-01
Hydrofluorocarbons are powerful greenhouse gases developed by industry after the phase-out of the ozone depleting chlorofluorocarbons and hydrochlorofluorocarbons required by the Montreal Protocol. The climate benefit of reducing the emissions of hydrofluorocarbons has been widely recognised, leading to an amendment of the Montreal Protocol (Kigali Amendment) calling for developed countries to start to phase-down hydrofluorocarbons by 2019 and in developing countries to follow with a freeze between 2024 and 2028. In this way, nearly half a degree Celsius of warming would be avoided by the end of the century. Hydrofluorocarbons are also included in the basket of gases controlled under the Kyoto Protocol of the United Nations Framework Convention on Climate Change. Annex I parties to the Convention submit annual national greenhouse gas inventories based on a bottom-up approach, which relies on declared anthropogenic activities. Top-down methodologies, based on atmospheric measurements and modelling, can be used in support to the inventory compilation. In this study we used atmospheric data from four European sites combined with the FLEXPART dispersion model and a Bayesian inversion method, in order to derive emissions of nine individual hydrofluorocarbons from the whole European Geographic Domain and from twelve regions within it, then comparing our results with the annual emissions that the European countries submit every year to the United Nations Framework Convention on Climate Change, as well as with the bottom-up Emissions Database for Global Atmospheric Research. We found several discrepancies when considering the specific compounds and on the country level. However, an overall agreement is found when comparing European aggregated data, which between 2008 and 2014 are on average 84.2 ± 28.0 Tg-CO2-eq·yr-1 against the 95.1 Tg-CO2-eq·yr-1 reported by UNFCCC in the same period. Therefore, in agreement with other studies, the gap on the global level between bottom-up estimates of Annex I countries and total global top-down emissions should be essentially due to emissions from non-reporting countries (non-Annex I).
Vedula, S. Swaroop; Li, Tianjing; Dickersin, Kay
2013-01-01
Background Details about the type of analysis (e.g., intent to treat [ITT]) and definitions (i.e., criteria for including participants in the analysis) are necessary for interpreting a clinical trial's findings. Our objective was to compare the description of types of analyses and criteria for including participants in the publication (i.e., what was reported) with descriptions in the corresponding internal company documents (i.e., what was planned and what was done). Trials were for off-label uses of gabapentin sponsored by Pfizer and Parke-Davis, and documents were obtained through litigation. Methods and Findings For each trial, we compared internal company documents (protocols, statistical analysis plans, and research reports, all unpublished), with publications. One author extracted data and another verified, with a third person verifying discordant items and a sample of the rest. Extracted data included the number of participants randomized and analyzed for efficacy, and types of analyses for efficacy and safety and their definitions (i.e., criteria for including participants in each type of analysis). We identified 21 trials, 11 of which were published randomized controlled trials, and that provided the documents needed for planned comparisons. For three trials, there was disagreement on the number of randomized participants between the research report and publication. Seven types of efficacy analyses were described in the protocols, statistical analysis plans, and publications, including ITT and six others. The protocol or publication described ITT using six different definitions, resulting in frequent disagreements between the two documents (i.e., different numbers of participants were included in the analyses). Conclusions Descriptions of analyses conducted did not agree between internal company documents and what was publicly reported. Internal company documents provide extensive documentation of methods planned and used, and trial findings, and should be publicly accessible. Reporting standards for randomized controlled trials should recommend transparent descriptions and definitions of analyses performed and which study participants are excluded. Please see later in the article for the Editors' Summary PMID:23382656
The costs and cost-effectiveness of an integrated sepsis treatment protocol.
Talmor, Daniel; Greenberg, Dan; Howell, Michael D; Lisbon, Alan; Novack, Victor; Shapiro, Nathan
2008-04-01
Sepsis is associated with high mortality and treatment costs. International guidelines recommend the implementation of integrated sepsis protocols; however, the true cost and cost-effectiveness of these are unknown. To assess the cost-effectiveness of an integrated sepsis protocol, as compared with conventional care. Prospective cohort study of consecutive patients presenting with septic shock and enrolled in the institution's integrated sepsis protocol. Clinical and economic outcomes were compared with a historical control cohort. Beth Israel Deaconess Medical Center. Overall, 79 patients presenting to the emergency department with septic shock in the treatment cohort and 51 patients in the control group. An integrated sepsis treatment protocol incorporating empirical antibiotics, early goal-directed therapy, intensive insulin therapy, lung-protective ventilation, and consideration for drotrecogin alfa and steroid therapy. In-hospital treatment costs were collected using the hospital's detailed accounting system. The cost-effectiveness analysis was performed from the perspective of the healthcare system using a lifetime horizon. The primary end point for the cost-effectiveness analysis was the incremental cost per quality-adjusted life year gained. Mortality in the treatment group was 20.3% vs. 29.4% in the control group (p = .23). Implementing an integrated sepsis protocol resulted in a mean increase in cost of approximately $8,800 per patient, largely driven by increased intensive care unit length of stay. Life expectancy and quality-adjusted life years were higher in the treatment group; 0.78 and 0.54, respectively. The protocol was associated with an incremental cost of $11,274 per life-year saved and a cost of $16,309 per quality-adjusted life year gained. In patients with septic shock, an integrated sepsis protocol, although not cost-saving, appears to be cost-effective and compares very favorably to other commonly delivered acute care interventions.
Park, Hyoung-Chul; Kim, Min Jeong; Lee, Bong Hwa
Although it is accepted that complicated appendicitis requires antibiotic therapy to prevent post-operative surgical infections, consensus protocols on the duration and regimens of treatment are not well established. This study aimed to compare the outcome of post-operative infectious complications in patients receiving old non-standardized and new standard antibiotic protocols, involving either 5 or 10 days of treatment, respectively. We enrolled 1,343 patients who underwent laparoscopic surgery for complicated appendicitis between January 2009 and December 2014. At the beginning of the new protocol, the patients were divided into two groups; 10 days of various antibiotic regimens (between January 2009 and June 2012, called the non-standardized protocol; n = 730) and five days of cefuroxime and metronidazole regimen (between July 2012 and December 2014; standardized protocol; n = 613). We compared the clinical outcomes, including surgical site infection (SSI) (superficial and deep organ/space infections) in the two groups. The standardized protocol group had a slightly shorter operative time (67 vs. 69 min), a shorter hospital stay (5 vs. 5.4 d), and lower medical cost (US$1,564 vs. US$1,654). Otherwise, there was no difference between the groups. No differences were found in the non-standardized and standard protocol groups with regard to the rate of superficial infection (10.3% vs. 12.7%; p = 0.488) or deep organ/space infection (2.3% vs. 2.1%; p = 0.797). In patients undergoing laparoscopic surgery for complicated appendicitis, five days of cefuroxime and metronidazole did not lead to more SSIs, and it decreased the medical costs compared with non-standardized antibiotic regimens.
Kirkpatrick, Daniel L; Hasham, Hasnain; Collins, Zachary; Johnson, Philip; Lemons, Steven; Shahzada, Hassan; Hunt, Suzanne L; Walter, Carissa; Hill, Jacqueline; Fahrbach, Thomas
2018-05-01
To determine whether treating benign biliary strictures via a stricture protocol reduced the probability of developing symptomatic recurrence and requiring surgical revision compared to nonprotocol treatment. A stricture protocol was designed to include serial upsizing of internal/external biliary drainage catheters to a target maximum dilation of 18-French, optional cholangioplasty at each upsizing, and maintenance of the largest catheter for at least 6 months. Patients were included in this retrospective analysis if they underwent biliary ductal dilation at a single institution from 2005 to 2016. Forty-two patients were included, 25 women and 17 men, with an average age of 51.9 years (standard deviation ± 14.6). Logistic regression models were used to determine the probability of symptomatic recurrence and surgical revision by stricture treatment type. Twenty-two patients received nonprotocol treatment, while 20 received treatment on a stricture protocol. After treatment, 7 (32%) patients in the nonprotocol group experienced clinical or laboratory recurrence of a benign stricture, whereas only 1 patient in the stricture protocol group experienced symptom recurrence. Patients in the protocol group were 8.9 times (95% confidence interval [CI] = 1.4-175.3) more likely to remain symptom free than patients in the nonprotocol group. Moreover, patients in the protocol group had an estimated 89% reduction in the probability of undergoing surgical revision compared to patients receiving nonprotocol treatment (odds ratio = .11, 95% CI = .01-.73). Establishing a stricture protocol may decrease the risk of stricture recurrence and the need for surgical revision when compared to a nonprotocol treatment approach. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Peres, Marco A.; Peres, Karen G.; Cascaes, Andreia M.; Correa, Marcos B.; Demarco, Flávio F.; Hallal, Pedro C.; Horta, Bernardo L.; Gigante, Denise P.; Menezes, Ana B.
2012-01-01
Background Most studies comparing prevalence of periodontal disease and risk factors by using partial protocols were performed in adult populations, with several studies being conducted in clinical settings. The aim of this study is to assess the accuracy of partial protocols in estimating the prevalence of periodontal outcomes in adolescents and young adults from two population-based birth cohorts from Pelotas, Brazil, and to assess differences in the estimation and strength of the effect measures when partial protocols are adopted compared to full-mouth examination. Methods Gingival bleeding at probing among adolescents (n = 339) and young adults (n = 720) and dental calculus and periodontal probing depth among young adults were assessed using full-mouth examinations and four partial protocols: Ramfjord teeth (RT), community periodontal index (CPI), and two random diagonal quadrants (1 and 3, 2 and 4). Socioeconomic, demographic, and periodontal health-related variables were also collected. Sensitivity, absolute and relative bias, and inflation factors were calculated. Prevalence ratio for each periodontal outcome for the risk factors was estimated. Results Two diagonal quadrants showed better accuracy; RT had the worst, whereas CPI presented an intermediate pattern when compared to full-mouth examination. For bleeding assessment in adolescence, RT and CPI underestimated by 18.4% and 16.2%, respectively, the true outcome prevalence, whereas among young adults, all partial protocols underestimated the prevalence. All partial protocols presented similar magnitude of association measures for all investigated periodontal potential risk factors. Conclusion Two diagonal quadrants protocol may be effective in identifying the risk factors for the most relevant periodontal outcomes in adolescence and in young adulthood. PMID:21859320
Peres, Marco A; Peres, Karen G; Cascaes, Andreia M; Correa, Marcos B; Demarco, Flávio F; Hallal, Pedro C; Horta, Bernardo L; Gigante, Denise P; Menezes, Ana B
2012-03-01
Most studies comparing prevalence of periodontal disease and risk factors by using partial protocols were performed in adult populations, with several studies being conducted in clinical settings. The aim of this study is to assess the accuracy of partial protocols in estimating the prevalence of periodontal outcomes in adolescents and young adults from two population-based birth cohorts from Pelotas, Brazil, and to assess differences in the estimation and strength of the effect measures when partial protocols are adopted compared to full-mouth examination. Gingival bleeding at probing among adolescents (n = 339) and young adults (n = 720) and dental calculus and periodontal probing depth among young adults were assessed using full-mouth examinations and four partial protocols: Ramfjord teeth (RT), community periodontal index (CPI), and two random diagonal quadrants (1 and 3, 2 and 4). Socioeconomic, demographic, and periodontal health-related variables were also collected. Sensitivity, absolute and relative bias, and inflation factors were calculated. Prevalence ratio for each periodontal outcome for the risk factors was estimated. Two diagonal quadrants showed better accuracy; RT had the worst, whereas CPI presented an intermediate pattern when compared to full-mouth examination. For bleeding assessment in adolescence, RT and CPI underestimated by 18.4% and 16.2%, respectively, the true outcome prevalence, whereas among young adults, all partial protocols underestimated the prevalence. All partial protocols presented similar magnitude of association measures for all investigated periodontal potential risk factors. Two diagonal quadrants protocol may be effective in identifying the risk factors for the most relevant periodontal outcomes in adolescence and in young adulthood.
Rosito, G; Sum, K; Chorne, N
2010-10-01
Indomethacin, a non-selective inhibitor of prostaglandin synthesis, is the gold standard treatment for patent ductus arteriosus (PDA). Indomethacin has been shown to permanently close the ductus and when given prophylactically, it reduces the incidence of PDA (1, 2). This study compares PDA closure and surgical ligation rates between patients using two different indomethacin administration protocols. This is a retrospective comparison analysis of 72 neonates, who received one of two indomethacin administration protocols. Our previous protocol suggested an initial dose of 0·2 mg/kg followed by two 0·1 mg/kg, with doses infused over 4 h and a 24-h dosing interval. A new potentially more useful protocol using the same mg/kg dose regimen but with doses infused over 30 min and a 12-h dosing interval, was evaluated. Each neonate was allowed three courses of treatment before surgical ligation was performed for persistent PDA. There were no statistically significant differences between the two protocol groups when comparing percentages of neonates with gestational age≤28 weeks, birth weight≤1000 g, male gender or receiving indomethacin for the indication of PDA prophylaxis vs. treatment. There was a trend towards a higher PDA closure rate and subsequently a lower PDA ligation rate in the new protocol when compared with the previous protocol. In this small population of premature neonates, there was a trend, but no significant difference, towards increasing PDA closure and lower surgical ligation rates in neonates given indomethacin with more frequent dosing and shorter infusion time. A well-powered randomized controlled trial is now needed. Copyright © 2010 The Authors. JCPT © 2010 Blackwell Publishing Ltd.
Polyethylene glycol 3350 based colon cleaning protocol: 2 d vs 4 d head to head comparison
Elitsur, Rotem; Butcher, Lisa; Vicki, Lund; Elitsur, Yoram
2013-01-01
AIM: To compare between 2 and 4 d colon cleansing protocols. METHODS: Children who were scheduled for colonoscopy procedure (2010-2012) for various medical reasons, were recruited from the pediatric gastroenterology clinic at Marshall University School of Medicine, Huntington, WV. Exclusion criteria were patients who were allergic to the medication used in the protocols [polyethylene glycol (PEG) 3350, Bisacodyl], or children with metabolic or renal diseases. Two PEG 3350 protocols for 4 d (A) and 2 d (B) were prescribed as previously described. A questionnaire describing the volume of PEG consumed, clinical data, and side effects were recorded. Colon preparation was graded by two observers according to previously described method. Main outcome measurements: Rate of adequate colon preparation. RESULTS: A total of 78 patients were considered for final calculation (group A: 40, group B: 38). Age and stool consistency at the last day was comparable in both groups, but the number of stools/day was significantly higher in group B (P = 0.001). Adequate colon preparation was reached in 57.5% (A) and 73.6% (B), respectively (P = 0.206). Side effects were minimal and comparable in both groups. There was no difference in children’s age, stool characteristics, or side effects between the children with adequate or inadequate colon preparation. Correlation and agreement between observers was excellent (Pearson correlation = 0.972, kappa = 1.0). CONCLUSION: No difference between protocols was observed, but the 2 d protocol was superior for its shorter time. Direct comparison between different colon cleansing protocols is crucial in order to establish the “gold standard” protocol for children. PMID:23596539
An economic and feasible Quantum Sealed-bid Auction protocol
NASA Astrophysics Data System (ADS)
Zhang, Rui; Shi, Run-hua; Qin, Jia-qi; Peng, Zhen-wan
2018-02-01
We present an economic and feasible Quantum Sealed-bid Auction protocol using quantum secure direct communication based on single photons in both the polarization and the spatial-mode degrees of freedom, where each single photon can carry two bits of classical information. Compared with previous protocols, our protocol has higher efficiency. In addition, we propose a secure post-confirmation mechanism without quantum entanglement to guarantee the security and the fairness of the auction.
Kaufman, David R; Sheehan, Barbara; Stetson, Peter; Bhatt, Ashish R; Field, Adele I; Patel, Chirag; Maisel, James Mark
2016-10-28
The process of documentation in electronic health records (EHRs) is known to be time consuming, inefficient, and cumbersome. The use of dictation coupled with manual transcription has become an increasingly common practice. In recent years, natural language processing (NLP)-enabled data capture has become a viable alternative for data entry. It enables the clinician to maintain control of the process and potentially reduce the documentation burden. The question remains how this NLP-enabled workflow will impact EHR usability and whether it can meet the structured data and other EHR requirements while enhancing the user's experience. The objective of this study is evaluate the comparative effectiveness of an NLP-enabled data capture method using dictation and data extraction from transcribed documents (NLP Entry) in terms of documentation time, documentation quality, and usability versus standard EHR keyboard-and-mouse data entry. This formative study investigated the results of using 4 combinations of NLP Entry and Standard Entry methods ("protocols") of EHR data capture. We compared a novel dictation-based protocol using MediSapien NLP (NLP-NLP) for structured data capture against a standard structured data capture protocol (Standard-Standard) as well as 2 novel hybrid protocols (NLP-Standard and Standard-NLP). The 31 participants included neurologists, cardiologists, and nephrologists. Participants generated 4 consultation or admission notes using 4 documentation protocols. We recorded the time on task, documentation quality (using the Physician Documentation Quality Instrument, PDQI-9), and usability of the documentation processes. A total of 118 notes were documented across the 3 subject areas. The NLP-NLP protocol required a median of 5.2 minutes per cardiology note, 7.3 minutes per nephrology note, and 8.5 minutes per neurology note compared with 16.9, 20.7, and 21.2 minutes, respectively, using the Standard-Standard protocol and 13.8, 21.3, and 18.7 minutes using the Standard-NLP protocol (1 of 2 hybrid methods). Using 8 out of 9 characteristics measured by the PDQI-9 instrument, the NLP-NLP protocol received a median quality score sum of 24.5; the Standard-Standard protocol received a median sum of 29; and the Standard-NLP protocol received a median sum of 29.5. The mean total score of the usability measure was 36.7 when the participants used the NLP-NLP protocol compared with 30.3 when they used the Standard-Standard protocol. In this study, the feasibility of an approach to EHR data capture involving the application of NLP to transcribed dictation was demonstrated. This novel dictation-based approach has the potential to reduce the time required for documentation and improve usability while maintaining documentation quality. Future research will evaluate the NLP-based EHR data capture approach in a clinical setting. It is reasonable to assert that EHRs will increasingly use NLP-enabled data entry tools such as MediSapien NLP because they hold promise for enhancing the documentation process and end-user experience. ©David R. Kaufman, Barbara Sheehan, Peter Stetson, Ashish R. Bhatt, Adele I. Field, Chirag Patel, James Mark Maisel. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 28.10.2016.
On the Nets. Comparing Web Browsers: Mosaic, Cello, Netscape, WinWeb and InternetWorks Life.
ERIC Educational Resources Information Center
Notess, Greg R.
1995-01-01
World Wide Web browsers are compared by speed, setup, hypertext transport protocol (HTTP) handling, management of file transfer protocol (FTP), telnet, gopher, and wide area information server (WAIS); bookmark options; and communication functions. Netscape has the most features, the fastest retrieval, sophisticated bookmark capabilities. (JMV)
Multi-Hop Teleportation of an Unknown Qubit State Based on W States
NASA Astrophysics Data System (ADS)
Zhou, Xiang-Zhen; Yu, Xu-Tao; Zhang, Zai-Chen
2018-04-01
Quantum teleportation is important in quantum communication networks. Considering that quantum state information is also transmitted between two distant nodes, intermediated nodes are employed and two multi-hop teleportation protocols based on W state are proposed. One is hop-by-hop teleportation protocol and the other is the improved multi-hop teleportation protocol with centralized unitary transformation. In hop-by-hop protocol, the transmitted quantum state needs to be recovered at every node on the route. In improved multi-hop teleportation protocol with centralized unitary transformation, intermediate nodes need not to recover the transmitted quantum state. Compared to the hop-by-hop protocol, the improved protocol can reduce the transmission delay and improve the transmission efficiency.
A Comparison of Inquiry and Worked Example Web-Based Instruction Using Physlets
ERIC Educational Resources Information Center
Lee, Kevin M.; Nicoll, Gayle; Brooks, David W.
2004-01-01
This paper compares two protocols for web-based instruction using simulations in an introductory physics class. The Inquiry protocol allowed students to control input parameters while the Worked Example protocol did not. Students in the Worked Example group performed significantly higher on a common assessment. The ramifications of this study are…
Patient doses from CT examinations in Turkey.
Ataç, Gökçe Kaan; Parmaksız, Aydın; İnal, Tolga; Bulur, Emine; Bulgurlu, Figen; Öncü, Tolga; Gündoğdu, Sadi
2015-01-01
We aimed to establish the first diagnostic reference levels (DRLs) for computed tomography (CT) examinations in adult and pediatric patients in Turkey and compare these with international DRLs. CT performance information and examination parameters (for head, chest, high-resolution CT of the chest [HRCT-chest], abdominal, and pelvic protocols) from 1607 hospitals were collected via a survey. Dose length products and effective doses for standard patient sizes were calculated from the reported volume CT dose index (CTDIvol). The median number of protocols reported from the 167 responding hospitals (10% response rate) was 102 across five different age groups. Third quartile CTDIvol values for adult pelvic and all pediatric body protocols were higher than the European Commission standards but were comparable to studies conducted in other countries. The radiation dose indicators for adult patients were similar to those reported in the literature, except for those associated with head protocols. CT protocol optimization is necessary for adult head and pediatric chest, HRCT-chest, abdominal, and pelvic protocols. The findings from this study are recommended for use as national DRLs in Turkey.
Patel, Neha A; Bly, Randall A; Adams, Seth; Carlin, Kristen; Parikh, Sanjay R; Dahl, John P; Manning, Scott
2018-02-01
Postoperative calcium management is challenging following pediatric thyroidectomy given potential limitations in self-reporting symptoms and compliance with phlebotomy. A protocol was created at our tertiary children's institution utilizing intraoperative parathyroid hormone (PTH) levels to guide electrolyte management during hospitalization. The objective of this study was to determine the effect of a new thyroidectomy postoperative management protocol on two primary outcomes: (1) the number of postoperative calcium blood draws and (2) the length of hospital stay. Institutional review board approved retrospective study (2010-2016). Consecutive pediatric total thyroidectomy and completion thyroidectomy ± neck dissection cases from 1/1/2010 through 8/5/2016 at a single tertiary children's institution were retrospectively reviewed before and after initiation of a new management protocol. All cases after 2/1/2014 comprised the experimental group (post-protocol implementation). The pre-protocol control group consisted of cases prior to 2/1/2014. Multivariable linear and Poisson regression models were used to compare the control and experimental groups for outcome measure of number of calcium lab draws and hospital length of stay. 53 patients were included (n = 23, control group; n = 30 experimental group). The median age was 15 years. 41 patients (77.4%) were female. Postoperative calcium draws decreased from a mean of 5.2 to 3.6 per day post-protocol implementation (Rate Ratio = 0.70, p < .001), adjusting for covariates. The mean number of total inpatient calcium draws before protocol initiation was 13.3 (±13.20) compared to 7.2 (±4.25) in the post-protocol implementation group. Length of stay was 2.1 days in the control group and 1.8 days post-protocol implementation (p = .29). Patients who underwent concurrent neck dissection had a longer mean length of stay of 2.32 days compared to 1.66 days in those patients who did not undergo a neck dissection (p = .02). Hypocalcemia was also associated with a longer mean length of stay of 2.41 days compared to 1.60 days in patients who did not develop hypocalcemia (p < .01). The number of calcium blood draws was significantly reduced after introduction of a standardized protocol based on intraoperative PTH levels. The hospital length of stay did not change. Adoption of a standardized postoperative protocol based on intraoperative PTH levels may reduce the number of blood draws in children undergoing thyroidectomy. Copyright © 2017 Elsevier B.V. All rights reserved.
Vazini Taher, Amir; Parnow, Abdolhossein
2017-05-01
Different methods of warm-up may have implications in improving various aspects of soccer performance. The present study aimed to investigate acute effects of soccer specific warm-up protocols on functional performance tests. This study using randomized within-subject design, investigated the performance of 22 collegiate elite soccer player following soccer specific warm-ups using dynamic stretching, static stretching, and FIFA 11+ program. Post warm-up examinations consisted: 1) Illinois Agility Test; 2) vertical jump; 3) 30 meter sprint; 4) consecutive turns; 5) flexibility of knee. Vertical jump performance was significantly lower following static stretching, as compared to dynamic stretching (P=0.005). Sprint performance declined significantly following static stretching as compared to FIFA 11+ (P=0.023). Agility time was significantly faster following dynamic stretching as compared to FIFA 11+ (P=0.001) and static stretching (P=0.001). Knee flexibility scores were significantly improved following the static stretching as compared to dynamic stretching (P=016). No significant difference was observed for consecutive turns between three warm-up protocol. The present finding showed that a soccer specific warm-up protocol relied on dynamic stretching is preferable in enhancing performance as compared to protocols relying on static stretches and FIFA 11+ program. Investigators suggest that while different soccer specific warm-up protocols have varied types of effects on performance, acute effects of dynamic stretching on performance in elite soccer players are assured, however application of static stretching in reducing muscle stiffness is demonstrated.
Portnoy, Orith; Guranda, Larisa; Apter, Sara; Eiss, David; Amitai, Marianne Michal; Konen, Eli
2011-11-01
The purpose of this study was to compare opacification of the urinary collecting system and radiation dose associated with three-phase 64-MDCT urographic protocols and those associated with a split-bolus dual-phase protocol including furosemide. Images from 150 CT urographic examinations performed with three scanning protocols were retrospectively evaluated. Group A consisted of 50 sequentially registered patients who underwent a three-phase protocol with saline infusion. Group B consisted of 50 sequentially registered patients who underwent a reduced-radiation three-phase protocol with saline. Group C consisted of 50 sequentially registered patients who underwent a dual-phase split-bolus protocol that included a low-dose furosemide injection. Opacification of the urinary collecting system was evaluated with segmental binary scoring. Contrast artifacts were evaluated, and radiation doses were recorded. Results were compared by analysis of variance. A significant reduction in mean effective radiation dose was found between groups A and B (p < 0.001) and between groups B and C (p < 0.001), resulting in 65% reduction between groups A and C (p < 0.001). This reduction did not significantly affect opacification score in any of the 12 urinary segments (p = 0.079). In addition, dense contrast artifacts overlying the renal parenchyma observed with the three-phase protocols (groups A and B) were avoided with the dual-phase protocol (group C) (p < 0.001). A dual-phase protocol with furosemide injection is the preferable technique for CT urography. In comparison with commonly used three-phase protocols, the dual-phase protocol significantly reduces radiation exposure dose without reduction in image quality.
Cheung, Leo Chin-Ting; Jones, Alice Yee-Men
2007-06-01
This study aims to investigate the effect of transcutaneous electrical nerve stimulation, applied at bilateral acupuncture points PC6 (Acu-TENS), on recovery heart rate (HR) in healthy subjects after treadmill running exercise. A single blinded, randomized controlled trial. Laboratory with healthy male subjects (n=28). Each subject participated in three separate protocols in random order. PROTOCOL A: The subject followed the Bruce protocol and ran on a treadmill until their HR reached 70% of their maximum (220-age). At this 'target' HR, the subject adopted the supine position and Acu-TENS to bilateral PC6 was commenced. PROTOCOL B: Identical to protocol A except that Acu-TENS was applied in the supine position for 45min prior to, but not after exercise. PROTOCOL C: Identical to protocol A except that placebo Acu-TENS was applied. Heart rate was recorded before and at 30s intervals after exercise until it returned to the pre-exercise baseline. The time for HR to return to baseline was compared for each protocol. Acu-TENS applied to bilateral PC6 resulted in a faster return to pre-exercise HR compared to placebo. Time required for HR to return to pre-exercise level in protocols A-C was 5.5+/-3.0; 4.8+/-3.3; 9.4+/-3.7 min, respectively (p<0.001). There was no statistical difference in HR recovery time between protocols A and B. Subjects expressed the lowest rate of perceived exertion score (RPE) at 70% maximum HR with protocol B. This study suggests that Acu-TENS applied to PC6 may facilitate HR recovery after high intensity treadmill exercise.
Muller, Matthew D.; Gao, Zhaohui; Drew, Rachel C.; Herr, Michael D.; Leuenberger, Urs A.
2011-01-01
The effects of cold air inhalation and isometric exercise on coronary blood flow are currently unknown, despite the fact that both cold air and acute exertion trigger angina in clinical populations. In this study, we used transthoracic Doppler echocardiography to measure coronary blood flow velocity (CBV; left anterior descending coronary artery) and myocardial function during cold air inhalation and handgrip exercise. Ten young healthy subjects underwent the following protocols: 5 min of inhaling cold air (cold air protocol), 5 min of inhaling thermoneutral air (sham protocol), 2 min of isometric handgrip at 30% of maximal voluntary contraction (grip protocol), and 5 min of isometric handgrip at 30% maximal voluntary contraction while breathing cold air (cold + grip protocol). Heart rate, blood pressure, inspired air temperature, CBV, myocardial function (tissue Doppler imaging), O2 saturation, and pulmonary function were measured. The rate-pressure product (RPP) was used as an index of myocardial O2 demand, whereas CBV was used as an index of myocardial O2 supply. Compared with the sham protocol, the cold air protocol caused a significantly higher RPP, but there was a significant reduction in CBV. The cold + grip protocol caused a significantly greater increase in RPP compared with the grip protocol (P = 0.045), but the increase in CBV was significantly less (P = 0.039). However, myocardial function was not impaired during the cold + grip protocol relative to the grip protocol alone. Collectively, these data indicate that there is a supply-demand mismatch in the coronary vascular bed when cold ambient air is breathed during acute exertion but myocardial function is preserved, suggesting an adequate redistribution of blood flow. PMID:21940852
Green, Robert C; Christensen, Kurt D; Cupples, L Adrienne; Relkin, Norman R; Whitehouse, Peter J; Royal, Charmaine D M; Obisesan, Thomas O; Cook-Deegan, Robert; Linnenbringer, Erin; Butson, Melissa Barber; Fasaye, Grace-Ann; Levinson, Elana; Roberts, J Scott
2015-10-01
Conventional multisession genetic counseling is currently recommended when disclosing apolipoprotein E (APOE) genotype for the risk of Alzheimer's disease (AD) in cognitively normal individuals. The objective of this study was to evaluate the safety of brief disclosure protocols for disclosing APOE genotype for the risk of AD. A randomized, multicenter noninferiority trial was conducted at four sites. Participants were asymptomatic adults having a first-degree relative with AD. A standard disclosure protocol by genetic counselors (SP-GC) was compared with condensed protocols, with disclosures by genetic counselors (CP-GC) and by physicians (CP-MD). Preplanned co-primary outcomes were anxiety and depression scales 12 months after disclosure. Three hundred and forty-three adults (mean age 58.3, range 33-86 years, 71% female, 23% African American) were randomly assigned to the SP-GC protocol (n = 115), CP-GC protocol (n = 116), or CP-MD protocol (n = 112). Mean postdisclosure scores on all outcomes were well below cut-offs for clinical concern across protocols. Comparing CP-GC with SP-GC, the 97.5% upper confidence limits at 12 months after disclosure on co-primary outcomes of anxiety and depression ranged from a difference of 1.2 to 2.0 in means (all P < .001 on noninferiority tests), establishing noninferiority for condensed protocols. Results were similar between European Americans and African Americans. These data support the safety of condensed protocols for APOE disclosure for those free of severe anxiety or depression who are actively seeking such information. Copyright © 2015 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.
Engelhardt, Othmar G.; Wood, John; Heath, Alan; Katz, Jacqueline M.; Peiris, Malik; Hoschler, Katja; Hungnes, Olav; Zhang, Wenqing; Van Kerkhove, Maria D.
2015-01-01
The microneutralization assay is commonly used to detect antibodies to influenza virus, and multiple protocols are used worldwide. These protocols differ in the incubation time of the assay as well as in the order of specific steps, and even within protocols there are often further adjustments in individual laboratories. The impact these protocol variations have on influenza serology data is unclear. Thus, a laboratory comparison of the 2-day enzyme-linked immunosorbent assay (ELISA) and 3-day hemagglutination (HA) microneutralization (MN) protocols, using A(H1N1)pdm09, A(H3N2), and A(H5N1) viruses, was performed by the CONSISE Laboratory Working Group. Individual laboratories performed both assay protocols, on multiple occasions, using different serum panels. Thirteen laboratories from around the world participated. Within each laboratory, serum sample titers for the different assay protocols were compared between assays to determine the sensitivity of each assay and were compared between replicates to assess the reproducibility of each protocol for each laboratory. There was good correlation of the results obtained using the two assay protocols in most laboratories, indicating that these assays may be interchangeable for detecting antibodies to the influenza A viruses included in this study. Importantly, participating laboratories have aligned their methodologies to the CONSISE consensus 2-day ELISA and 3-day HA MN assay protocols to enable better correlation of these assays in the future. PMID:26108286
Evaluation of Protocol Uniformity Concerning Laparoscopic Cholecystectomy in The Netherlands
Goossens, Richard H. M.; van Eijk, Daan J.; Lange, Johan F.
2008-01-01
Background Iatrogenic bile duct injury remains a current complication of laparoscopic cholecystectomy. One uniform and standardized protocol, based on the “critical view of safety” concept of Strasberg, should reduce the incidence of this complication. Furthermore, owing to the rapid development of minimally invasive surgery, technicians are becoming more frequently involved. To improve communication between the operating team and technicians, standardized actions should also be defined. The aim of this study was to compare existing protocols for laparoscopic cholecystectomy from various Dutch hospitals. Methods Fifteen Dutch hospitals were contacted for evaluation of their protocols for laparoscopic cholecystectomy. All evaluated protocols were divided into six steps and were compared accordingly. Results In total, 13 hospitals responded—5 academic hospitals, 5 teaching hospitals, 3 community hospitals—of which 10 protocols were usable for comparison. Concerning the trocar positions, only minor differences were found. The concept of “critical view of safety” was represented in just one protocol. Furthermore, the order of clipping and cutting the cystic artery and duct differed. Descriptions of instruments and apparatus were also inconsistent. Conclusions Present protocols differ too much to define a universal procedure among surgeons in The Netherlands. The authors propose one (inter)national standardized protocol, including standardized actions. This uniform standardized protocol has to be officially released and recommended by national scientific associations (e.g., the Dutch Society of Surgery) or international societies (e.g., European Association for Endoscopic Surgery and Society of American Gastrointestinal and Endoscopic Surgeons). The aim is to improve patient safety and professional communication, which are necessary for new developments. PMID:18224485
Capozzi, F; Giordano, S; Aboal, J R; Adamo, P; Bargagli, R; Boquete, T; Di Palma, A; Real, C; Reski, R; Spagnuolo, V; Steinbauer, K; Tretiach, M; Varela, Z; Zechmeister, H; Fernández, J A
2016-07-01
To develop an internationally standardized protocol for the moss bag technique application, the research team participating in the FP7 European project "MOSSclone" focused on the optimization of the moss bags exposure in terms of bag characteristics (shape of the bags, mesh size, weight/surface ratio), duration and height of exposure by comparing traditional moss bags to a new concept bag, "Mossphere". In particular, the effects of each variable on the metal uptake from the air were evaluated by a systematic experimental design carried out in urban, industrial, agricultural and background areas of three European countries with oceanic, Mediterranean and continental climate. The results evidenced that the shape, the mesh size of the bags and the exposure height (in the tested ranges), did not significantly influence the uptake capacity of the transplanted moss. The aspects more affecting the element uptake were represented by the density of the moss inside the bags and the relative ratio between its weight and the surface area of the bag. We found that, the lower the density, the higher the uptake recorded. Moreover, three weeks of exposure were not enough to have a consistent uptake signal in all the environments tested, thus we suggest an exposure period not shorter than 6 weeks, which is appropriate in most situations. The above results were confirmed in all the countries and scenarios tested. The adoption of a shared exposure protocol by the research community is strongly recommended since it is a key aspect to make biomonitoring surveys directly comparable, also in view of its recognition as a monitoring method by the EU legislation. Copyright © 2016 Elsevier Ltd. All rights reserved.
Amin, Ruhul; Islam, S K Hafizul; Biswas, G P; Khan, Muhammad Khurram; Obaidat, Mohammad S
2015-11-01
In order to access remote medical server, generally the patients utilize smart card to login to the server. It has been observed that most of the user (patient) authentication protocols suffer from smart card stolen attack that means the attacker can mount several common attacks after extracting smart card information. Recently, Lu et al.'s proposes a session key agreement protocol between the patient and remote medical server and claims that the same protocol is secure against relevant security attacks. However, this paper presents several security attacks on Lu et al.'s protocol such as identity trace attack, new smart card issue attack, patient impersonation attack and medical server impersonation attack. In order to fix the mentioned security pitfalls including smart card stolen attack, this paper proposes an efficient remote mutual authentication protocol using smart card. We have then simulated the proposed protocol using widely-accepted AVISPA simulation tool whose results make certain that the same protocol is secure against active and passive attacks including replay and man-in-the-middle attacks. Moreover, the rigorous security analysis proves that the proposed protocol provides strong security protection on the relevant security attacks including smart card stolen attack. We compare the proposed scheme with several related schemes in terms of computation cost and communication cost as well as security functionalities. It has been observed that the proposed scheme is comparatively better than related existing schemes.
Zakaria, Golam Abu; Schütte, Wilhelm
2003-01-01
The determination of absorbed dose to water for high-energy photon and electron beams is performed in Germany according to the dosimetry protocol DIN 6800-2 (1997). At an international level, the main protocols used are the AAPM dosimetry protocol TG-51 (1999) and the IAEA Code of Practice TRS-398 (2000). The present paper systematically compares these three dosimetry protocols, and identifies similarities and differences. The investigations were performed using 4 and 10 MV photon beams, as well as 6, 8, 9, 10, 12 and 14 MeV electron beams. Two cylindrical and two plane-parallel type chambers were used for measurements. In general, the discrepancies among the three protocols were 1.0% for photon beams and 1.6% for electron beams. Comparative measurements in the context of measurement technical control (MTK) with TLD showed a deviation of less than 1.3% between the measurements obtained according to protocols DIN 6800-2 and MTK (exceptions: 4 MV photons with 2.9% and 6 MeV electrons with 2.4%). While only cylindrical chambers were used for photon beams, measurements of electron beams were performed using both cylindrical and plane-parallel chambers (the latter used after a cross-calibration to a cylindrical chamber, as required by the respective dosimetry protocols). Notably, unlike recommended in the corresponding protocols, we found out that cylindrical chambers can be used also for energies from 6 to 10 MeV.
TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, J; Chan, F; Newman, B
2014-06-15
Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze themore » scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds.« less
Combining Electrolysis and Electroporation for Tissue Ablation.
Phillips, Mary; Rubinsky, Liel; Meir, Arie; Raju, Narayan; Rubinsky, Boris
2015-08-01
Electrolytic ablation is a method that operates by delivering low magnitude direct current to the target region over long periods of time, generating electrolytic products that destroy cells. This study was designed to explore the hypothesis stating that electrolytic ablation can be made more effective when the electrolysis-producing electric charges are delivered using electric pulses with field strength typical in reversible electroporation protocols. (For brevity we will refer to tissue ablation protocols that combine electroporation and electrolysis as E(2).) The mechanistic explanation of this hypothesis is related to the idea that products of electrolysis generated by E(2) protocols can gain access to the interior of the cell through the electroporation permeabilized cell membrane and therefore cause more effective cell death than from the exterior of an intact cell. The goal of this study is to provide a first-order examination of this hypothesis by comparing the charge dosage required to cause a comparable level of damage to a rat liver, in vivo, when using either conventional electrolysis or E(2) approaches. Our results show that E(2) protocols produce tissue damage that is consistent with electrolytic ablation. Furthermore, E(2) protocols cause damage comparable to that produced by conventional electrolytic protocols while delivering orders of magnitude less charge to the target tissue over much shorter periods of time. © The Author(s) 2014.
Rogers, Rebecca G; Gardner, Michael O; Tool, Kevin J; Ainsley, Jeanne; Gilson, George
2000-01-01
Objective To compare the costs of a protocol of active management of labor with those of traditional labor management. Design Cost analysis of a randomized controlled trial. Methods From August 1992 to April 1996, we randomly allocated 405 women whose infants were delivered at the University of New Mexico Health Sciences Center, Albuquerque, to an active management of labor protocol that had substantially reduced the duration of labor or a control protocol. We calculated the average cost for each delivery, using both actual costs and charges. Results The average cost for women assigned to the active management protocol was $2,480.79 compared with an average cost of $2,528.61 for women in the control group (P = 0.55). For women whose infant was delivered by cesarean section, the average cost was $4,771.54 for active management of labor and $4,468.89 for the control protocol (P = 0.16). Spontaneous vaginal deliveries cost an average of $27.00 more for actively managed patients compared with the cost for the control protocol. Conclusions The reduced duration of labor by active management did not translate into significant cost savings. Overall, an average cost saving of only $47.91, or 2%, was achieved for labors that were actively managed. This reduction in cost was due to a decrease in the rate of cesarean sections in women whose labor was actively managed and not to a decreased duration of labor. PMID:10778374
Ngo, Thoai D; Park, Min Hae; Xiao, Yuanhong
2012-01-01
Objective To compare the effectiveness, in terms of complete abortion, of the World Health Organization (WHO)- and the China-recommended protocol for first-trimester medical abortion. Methods A retrospective analysis of clinical data from women presenting for first trimester medical abortion between January 2009 and August 2010 at reproductive health clinics in Qingdao, Xi’an, Nanjing, Nanning, and Zhengzhou was conducted. One clinic in Qingdao administered the WHO-recommended protocol (200 mg mifepristone orally followed by 0.8 mg misoprostol buccally 36–48 hours later). Four clinics in the other locations provided the China-recommended procedure (Day 1: 50 mg of mifepristone in the morning, 25 mg in the afternoon; Day 2: 50 mg of mifepristone in the morning, 25 mg in the afternoon; Day 3: 0.6 mg oral misoprostol). Data on reproductive and demographic characteristics were extracted from clinic records, and complete termination was determined on day 14 (post-mifepristone administration). Results A total of 337 women underwent early medical abortion (167 WHO- and 170 China-recommended procedures). Complete abortion was significantly higher among women who had the WHO protocol than those who received the China protocol (91.0% vs 77.7%, respectively; P < 0.001). Women using the China-recommended protocol were three times more likely to require an additional dose of misoprostol than women using the WHO protocol (21.8% vs 7.8%, respectively; P < 0.001), and had significantly more bleeding on the day of misoprostol administration (12.5 mL vs 18.5 mL; P < 0.001). Conclusion This clinical audit provides preliminary evidence suggesting the WHO-recommended protocol may be more effective than the China-recommended protocol for early medical abortion. A larger scale study is necessary to compare the methods’ effectiveness and acceptability. PMID:22505831
Coexistence of WiFi and WiMAX systems based on PS-request protocols.
Kim, Jongwoo; Park, Suwon; Rhee, Seung Hyong; Choi, Yong-Hoon; Chung, Young-uk; Hwang, Ho Young
2011-01-01
We introduce both the coexistence zone within the WiMAX frame structure and a PS-Request protocol for the coexistence of WiFi and WiMAX systems sharing a frequency band. Because we know that the PS-Request protocol has drawbacks, we propose a revised PS-Request protocol to improve the performance. Two PS-Request protocols are based on the time division operation (TDO) of WiFi system and WiMAX system to avoid the mutual interference, and use the vestigial power management (PwrMgt) bit within the Frame Control field of the frames transmitted by a WiFi AP. The performance of the revised PS-Request protocol is evaluated by computer simulation, and compared to those of the cases without a coexistence protocol and to the original PS-Request protocol.
Efficient model checking of network authentication protocol based on SPIN
NASA Astrophysics Data System (ADS)
Tan, Zhi-hua; Zhang, Da-fang; Miao, Li; Zhao, Dan
2013-03-01
Model checking is a very useful technique for verifying the network authentication protocols. In order to improve the efficiency of modeling and verification on the protocols with the model checking technology, this paper first proposes a universal formalization description method of the protocol. Combined with the model checker SPIN, the method can expediently verify the properties of the protocol. By some modeling simplified strategies, this paper can model several protocols efficiently, and reduce the states space of the model. Compared with the previous literature, this paper achieves higher degree of automation, and better efficiency of verification. Finally based on the method described in the paper, we model and verify the Privacy and Key Management (PKM) authentication protocol. The experimental results show that the method of model checking is effective, which is useful for the other authentication protocols.
Wastewater GHG Accounting Protocols as Compared to the State of GHG Science.
Willis, John L; Yuan, Zhiguo; Murthy, Sudhir
2016-08-01
Greenhouse gas (GHG) accounting protocols have addressed emissions from wastewater conveyance and treatment using a variety of simplifying methodologies. While these methodologies vary to some degree by protocol, within each protocol they provide consistent tools for organizational entities of varying size and scope to report and verify GHG emissions. Much of the science supporting these methodologies is either limited or the protocols have failed to keep abreast of developing GHG research. This state-of-the-art review summarizes the sources of direct GHG emissions (both those covered and not covered in current protocols) from wastewater handling; provides a review of the wastewater-related methodologies in a select group of popular protocols; and discusses where research has out-paced protocol methodologies and other areas where the supporting science is relatively weak and warrants further exploration.
Historical Overview of Data Communication With Analysis of a Selective Repeat Protocol
1991-03-01
optical fiber have created international and national communications nets. Personal computers have effected , if not where, certainly how we conduct...Telecommunications entails disciplines, means and methodologies to communicate over distances, in effect to transmit voice, video, facimile, and computer data...having and will continue to have significant effect on the integration of data processing and the telecommunications industry. The high data transmission
Industry Studies 2004: Biotechnology
2004-01-01
for biological agent research, development, and production are available on the open market. Since biological weapons are relatively cheap, easy to...growing concern is that non-state actors will acquire and use a biological weapon , the “poor man’s nuclear weapon .” Such action is extremely difficult...to detect and counter. International Protocols and the Need to Control Agents and Technologies - The Biological and Toxin Weapons Convention
ICASE Semiannual Report, 1 April 1990 - 30 September 1990
1990-11-01
underlies parallel simulation protocols that synchronize based on logical time (all known approaches). This framework describes a suf- ficient set of...conducted primarily by visiting scientists from universities and from industry, who have resident appointments for limited periods of time , and by consultants...wave equation with point sources and semireflecting impedance boundary conditions. For sources that are piece- wise polynomial in time we get a finite
U.S. Army War College: Key Strategic Issues List
2006-07-01
Protocol (EoIP) b. Soldier vs contractor operated and maintained tactical equipment. Are the new soldier systems so “ high tech ” that we cannot fight...approaches to meet the high tech skills demanded by our transformation TOEs? (G-3 ACD) 9. War and Society: a. Has the Army adapted from Industrial-Age to...61 United States Military Academy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 U.S. Army Corps of Engineers
Team Faces Tough Odds to Implement New Phone Network | Poster
It was a Saturday, in the final stretch of winter in late February, and the temperature peaked to a pleasant 66 degrees. Many people were outside enjoying the spring-like weather; however, the Voice over Internet Protocol (VoIP) Deployment Team was hard at work at Industry Lane. The team of 10 was installing the new voice-only network, including deploying 145 phones, switching
Wireless Communications in Reverberant Environments
2015-01-01
Secure Wireless Agent Testbed (SWAT), the Protocol Engineering Advanced Networking (PROTEAN) Research Group, the Data Fusion Laboratory (DFL), and the...constraints of their application. 81 Bibliography [1] V. Gungor and G. Hancke, “Industrial wireless sensor networks : Challenges, design principles, and...Bhattacharya, “Path loss estimation for a wireless sensor network for application in ship,” Int. J. of Comput. Sci. and Mobile Computing, vol. 2, no. 6, pp
Pérez-González, J A; González, R; Querol, A; Sendra, J; Ramón, D
1993-01-01
A genetic transformation system for an industrial wine yeast strain is presented here. The system is based on the acquisition of cycloheximide resistance and is a direct adaptation of a previously published procedure for brewing yeasts (L. Del Pozo, D. Abarca, M. G. Claros, and A. Jiménez, Curr. Genet. 19:353-358, 1991). Transformants arose at an optimal frequency of 0.5 transformant per microgram of DNA, are stable in the absence of selective pressure, and produce wine in the same way as the untransformed industrial strain. By using this transformation protocol, a filamentous fungal beta-(1,4)-endoglucanase gene has been expressed in an industrial wine yeast under the control of the yeast actin gene promoter. Endoglucanolytic wine yeast secretes the fungal enzyme to the must, producing a wine with an increased fruity aroma. Images PMID:8215355
Qu, Shu-Gen; Gao, Jin; Tang, Bo; Yu, Bo; Shen, Yue-Ping; Tu, Yu
2018-01-01
Low-dose ionizing radiation (LDIR) may increase the mortality of solid cancers in nuclear industry workers, but only few individual cohort studies exist, and the available reports have low statistical power. The aim of the present study was to focus on solid cancer mortality risk from LDIR in the nuclear industry using standard mortality ratios (SMRs) and 95% confidence intervals. A systematic literature search through the PubMed and Embase databases identified 27 studies relevant to this meta-analysis. There was statistical significance for total, solid and lung cancers, with meta-SMR values of 0.88, 0.80, and 0.89, respectively. There was evidence of stochastic effects by IR, but more definitive conclusions require additional analyses using standardized protocols to determine whether LDIR increases the risk of solid cancer-related mortality. PMID:29725540
Perumal, Madhumathy; Dhandapani, Sivakumar
2015-01-01
Data gathering and optimal path selection for wireless sensor networks (WSN) using existing protocols result in collision. Increase in collision further increases the possibility of packet drop. Thus there is a necessity to eliminate collision during data aggregation. Increasing the efficiency is the need of the hour with maximum security. This paper is an effort to come up with a reliable and energy efficient WSN routing and secure protocol with minimum delay. This technique is named as relay node based secure routing protocol for multiple mobile sink (RSRPMS). This protocol finds the rendezvous point for optimal transmission of data using a "splitting tree" technique in tree-shaped network topology and then to determine all the subsequent positions of a sink the "Biased Random Walk" model is used. In case of an event, the sink gathers the data from all sources, when they are in the sensing range of rendezvous point. Otherwise relay node is selected from its neighbor to transfer packets from rendezvous point to sink. A symmetric key cryptography is used for secure transmission. The proposed relay node based secure routing protocol for multiple mobile sink (RSRPMS) is experimented and simulation results are compared with Intelligent Agent-Based Routing (IAR) protocol to prove that there is increase in the network lifetime compared with other routing protocols.
ESR paper on structured reporting in radiology.
2018-02-01
Structured reporting is emerging as a key element of optimising radiology's contribution to patient outcomes and ensuring the value of radiologists' work. It is being developed and supported by many national and international radiology societies, based on the recognised need to use uniform language and structure to accurately describe radiology findings. Standardisation of report structures ensures that all relevant areas are addressed. Standardisation of terminology prevents ambiguity in reports and facilitates comparability of reports. The use of key data elements and quantified parameters in structured reports ("radiomics") permits automatic functions (e.g. TNM staging), potential integration with other clinical parameters (e.g. laboratory results), data sharing (e.g. registries, biobanks) and data mining for research, teaching and other purposes. This article outlines the requirements for a successful structured reporting strategy (definition of content and structure, standard terminologies, tools and protocols). A potential implementation strategy is outlined. Moving from conventional prose reports to structured reporting is endorsed as a positive development, and must be an international effort, with international design and adoption of structured reporting templates that can be translated and adapted in local environments as needed. Industry involvement is key to success, based on international data standards and guidelines. • Standardisation of radiology report structure ensures completeness and comparability of reports. • Use of standardised language in reports minimises ambiguity. • Structured reporting facilitates automatic functions, integration with other clinical parameters and data sharing. • International and inter-society cooperation is key to developing successful structured report templates. • Integration with industry providers of radiology-reporting software is also crucial.
Ganesh, Praveen; Murthy, Jyotsna; Ulaghanathan, Navitha; Savitha, V H
2015-07-01
To study the growth and speech outcomes in children who were operated on for unilateral cleft lip and palate (UCLP) by a single surgeon using two different treatment protocols. A total of 200 consecutive patients with nonsyndromic UCLP were randomly allocated to two different treatment protocols. Of the 200 patients, 179 completed the protocol. However, only 85 patients presented for follow-up during the mixed dentition period (7-10 years of age). The following treatment protocol was followed. Protocol 1 consisted of the vomer flap (VF), whereby patients underwent primary lip nose repair and vomer flap for hard palate single-layer closure, followed by soft palate repair 6 months later; Protocol 2 consisted of the two-flap technique (TF), whereby the cleft palate (CP) was repaired by two-flap technique after primary lip and nose repair. GOSLON Yardstick scores for dental arch relation, and speech outcomes based on universal reporting parameters, were noted. A total of 40 patients in the VF group and 45 in the TF group completed the treatment protocols. The GOSLON scores showed marginally better outcomes in the VF group compared to the TF group. Statistically significant differences were found only in two speech parameters, with better outcomes in the TF group. Our results showed marginally better growth outcome in the VF group compared to the TF group. However, the speech outcomes were better in the TF group. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Stanzione, Arnaldo; Imbriaco, Massimo; Cocozza, Sirio; Fusco, Ferdinando; Rusconi, Giovanni; Nappi, Carmela; Mirone, Vincenzo; Mangiapia, Francesco; Brunetti, Arturo; Ragozzino, Alfonso; Longo, Nicola
2016-12-01
To prospectively determine the diagnostic accuracy of a biparametric 3T magnetic resonance imaging protocol (BP-MRI) for prostatic cancer detection, compared to a multiparametric MRI protocol (MP-MRI), in a biopsy naïve patient population. Eighty-two untreated patients (mean age 65±7.6years) with clinical suspicion of prostate cancer and/or altered prostate-specific antigen (PSA) levels underwent a MP-MRI, including T2-weighted imaging, diffusion-weighted imaging (with the correspondent apparent diffusion coefficient maps) and dynamic contrast enhanced sequence, followed by prostate biopsy. Two radiologists reviewed both the BP-MRI and the MP-MRI protocols to establish a radiological diagnosis. Receiver operating characteristics curves were obtained to determine the diagnostic performance of the two protocols. The mean PSA level was 8.8±8.1ng/ml. A total of 34 prostatic tumors were identified, with a Gleason score that ranged from 3+3 to 5+4. Of these 34 tumors, 29 were located within the peripheral zone and 5 in the transitional zone. BP-MRI and MP-MRI showed a similar performance in terms of overall diagnostic accuracy, with an area under the curve of 0.91 and 0.93, respectively (p=n.s.). BP-MRI prostate protocol is feasible for prostatic cancer detection compared to a standard MP-MRI protocol, requiring a shorter acquisition and interpretation time, with comparable diagnostic accuracy to the conventional protocol, without the administration of gadolinium-based contrast agent. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Weitzman, Vanessa N; Engmann, Lawrence; DiLuigi, Andrea; Maier, Donald; Nulsen, John; Benadiva, Claudio
2009-07-01
To compare IVF outcomes in poor-responder patients undergoing stimulation after luteal phase E(2) patch/GnRH antagonist (LPG) protocol versus microdose GnRH agonist protocol. Retrospective analysis. University-based IVF center. Forty-five women undergoing ovarian stimulation for IVF using the LPG protocol were compared with 76 women stimulated with the microdose GnRH agonist protocol from May 2005 to April 2006. Cancellation rate, number of oocytes retrieved, and clinical pregnancy rates. The mean number of oocytes (9.1 +/- 4.1 vs. 8.9 +/- 4.3) and mature oocytes (6.7 +/- 3.5 vs. 6.8 +/- 3.1) retrieved were similar, as were the fertilization rates (70.0% +/- 24.2% vs. 69.9% +/- 21.5%) and the number of embryos transferred (2.5 +/- 1.1 vs. 2.7 +/- 1.3). The cancellation rate was not significantly different between the groups (13/45, 28.9% vs. 23/76, 30.3%). Likewise, there were no significant differences among the implantation rate (15.0% vs. 12.5%), clinical pregnancy rate (43.3% vs. 45.1%), and ongoing pregnancy rate per transfer (33.3% vs. 26.0%) between both groups. This study demonstrates that the use of an E(2) patch and a GnRH antagonist during the preceding luteal phase in patients with a history of failed cycles can provide similar IVF outcomes when compared with the microdose GnRH agonist protocol.
Laurin, Nancy; Frégeau, Chantal
2012-01-01
The goal of this work was to optimize and validate a fast amplification protocol for the multiplex amplification of the STR loci included in AmpFlSTR(®) Profiler Plus(®) to expedite human DNA identification. By modifying the cycling conditions and by combining the use of a DNA polymerase optimized for high speed PCR (SpeedSTAR™ HS) and a more efficient thermal cycler instrument (Bio-RAD C1000™), we were able to reduce the amplification process from 4h to 26 min. No modification to the commercial AmpFlSTR(®) Profiler Plus(®) primer mix was required. When compared to the current Royal Canadian Mounted Police (RCMP) amplification protocol, no differences with regards to specificity, sensitivity, heterozygote peak height ratios and overall profile balance were noted. Moreover, complete concordance was obtained with profiles previously generated with the standard amplification protocol and minor alleles in mixture samples were reliably typed. An increase in n-4 stutter ratios (2.2% on average for all loci) was observed for profiles amplified with the fast protocol compared to the current procedure. Our results document the robustness of this rapid amplification protocol for STR profiling using the AmpFlSTR(®) Profiler Plus(®) primer set and demonstrate that comparable data can be obtained in substantially less time. This new approach could provide an alternative option to current multiplex STR typing amplification protocols in order to increase throughput or expedite time-sensitive cases. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Game-theoretic perspective of Ping-Pong protocol
NASA Astrophysics Data System (ADS)
Kaur, Hargeet; Kumar, Atul
2018-01-01
We analyse Ping-Pong protocol from the point of view of a game. The analysis helps us in understanding the different strategies of a sender and an eavesdropper to gain the maximum payoff in the game. The study presented here characterizes strategies that lead to different Nash equilibriums. We further demonstrate the condition for Pareto optimality depending on the parameters used in the game. Moreover, we also analysed LM05 protocol and compared it with PP protocol from the point of view of a generic two-way QKD game with or without entanglement. Our results provide a deeper understanding of general two-way QKD protocols in terms of the security and payoffs of different stakeholders in the protocol.
A new quantum sealed-bid auction protocol with secret order in post-confirmation
NASA Astrophysics Data System (ADS)
Wang, Jing-Tao; Chen, Xiu-Bo; Xu, Gang; Meng, Xiang-Hua; Yang, Yi-Xian
2015-10-01
A new security protocol for quantum sealed-bid auction is proposed to resist the collusion attack from some malicious bidders. The most significant feature of this protocol is that bidders prepare their particles with secret order in post-confirmation for encoding bids. In addition, a new theorem and its proof are given based on the theory of combinatorial mathematics, which can be used as evaluation criteria for the collusion attack. It is shown that the new protocol is immune to the collusion attack and meets the demand for a secure auction. Compared with those previous protocols, the security, efficiency and availability of the proposed protocol are largely improved.
Security of the arbitrated quantum signature protocols revisited
NASA Astrophysics Data System (ADS)
Kejia, Zhang; Dan, Li; Qi, Su
2014-01-01
Recently, much attention has been paid to the study of arbitrated quantum signature (AQS). Among these studies, the cryptanalysis of some AQS protocols and a series of improved ideas have been proposed. Compared with the previous analysis, we present a security criterion, which can judge whether an AQS protocol is able to prevent the receiver (i.e. one participant in the signature protocol) from forging a legal signature. According to our results, it can be seen that most AQS protocols which are based on the Zeng and Keitel (ZK) model are susceptible to a forgery attack. Furthermore, we present an improved idea of the ZK protocol. Finally, some supplement discussions and several interesting topics are provided.
One Step Quantum Key Distribution Based on EPR Entanglement
Li, Jian; Li, Na; Li, Lei-Lei; Wang, Tao
2016-01-01
A novel quantum key distribution protocol is presented, based on entanglement and dense coding and allowing asymptotically secure key distribution. Considering the storage time limit of quantum bits, a grouping quantum key distribution protocol is proposed, which overcomes the vulnerability of first protocol and improves the maneuverability. Moreover, a security analysis is given and a simple type of eavesdropper’s attack would introduce at least an error rate of 46.875%. Compared with the “Ping-pong” protocol involving two steps, the proposed protocol does not need to store the qubit and only involves one step. PMID:27357865
The Willingness of Non-Industrial Private Forest Owners to Enter California's Carbon Offset Market.
Kelly, Erin Clover; Gold, Gregg J; Di Tommaso, Joanna
2017-11-01
While non-industrial private forest landowners have a significant amount of forest landholdings in the US, they are underrepresented in the California cap-and-trade market forest offset program. Additional participation could benefit both the market and non-industrial private forest landowners. We developed a mail questionnaire which served as both a survey instrument and outreach tool about the market. Questions covered forest ownership objectives, landowners' future plans for forests, views of climate change, and attitudes and intentions regarding forest carbon offset project development. We sampled from five Northern California counties for a total of 143 usable surveys. Three different groups of landowners were identified based on their management objectives: amenity (including protecting nature and recreation); legacy (passing land to children and/or maintaining a farm or ranch); and income. Landowner objective groups differed on several key variables, particularly related to potential motivations for joining the market, while all landowners expressed concerns about protocol requirements. Regardless of ownership objectives, over half expressed that receiving revenue from their forests would be an important motivator to join, though most were unwilling to satisfy protocol requirements, even after learning of the potential benefits of program participation. Thus, participation appears to be limited by the costly and complex project development process, as well as a lack of landowner awareness. Extending these lessons, we assert that different landowners may approach payment for ecosystem services programs with different needs, awareness, and motivations, which provide important lessons for those who conduct landowner outreach and for PES program designers.
The Willingness of Non-Industrial Private Forest Owners to Enter California's Carbon Offset Market
NASA Astrophysics Data System (ADS)
Kelly, Erin Clover; Gold, Gregg J.; Di Tommaso, Joanna
2017-11-01
While non-industrial private forest landowners have a significant amount of forest landholdings in the US, they are underrepresented in the California cap-and-trade market forest offset program. Additional participation could benefit both the market and non-industrial private forest landowners. We developed a mail questionnaire which served as both a survey instrument and outreach tool about the market. Questions covered forest ownership objectives, landowners' future plans for forests, views of climate change, and attitudes and intentions regarding forest carbon offset project development. We sampled from five Northern California counties for a total of 143 usable surveys. Three different groups of landowners were identified based on their management objectives: amenity (including protecting nature and recreation); legacy (passing land to children and/or maintaining a farm or ranch); and income. Landowner objective groups differed on several key variables, particularly related to potential motivations for joining the market, while all landowners expressed concerns about protocol requirements. Regardless of ownership objectives, over half expressed that receiving revenue from their forests would be an important motivator to join, though most were unwilling to satisfy protocol requirements, even after learning of the potential benefits of program participation. Thus, participation appears to be limited by the costly and complex project development process, as well as a lack of landowner awareness. Extending these lessons, we assert that different landowners may approach payment for ecosystem services programs with different needs, awareness, and motivations, which provide important lessons for those who conduct landowner outreach and for PES program designers.
USDA-ARS?s Scientific Manuscript database
A greenhouse study was conducted that compared the protein mark retention time of a well established rabbit IgG protein detection protocol with those of three newer, less expensive protein detection protocols designed to detect casein in bovine milk, egg albumin in chicken egg whites, and soy tryp...
NASA Astrophysics Data System (ADS)
Ursache, M.; Avădanei, M. L.; Ciobanu, L.; Loghin, M. C.; Ionesi, D. S.; Loghin, E.
2017-10-01
The paper presents the objectives, the planned outputs and the innovative aspects of the project entitled “Developing new skills for the extroversion specializations of fashion industry in Europe”, acronym EXTRO SKILLS, which is co-financed by the European Commission under the Erasmus+ Programme, Key Action 2 - Strategic Partnerships. This is a 30 months project and started on December 1-st, 2015. The project aims to bridge the gap between fashion industries and lack of specific expertise and experts of SMEs in these industries. Fashion industries require a more qualified workforce and, therefore, the availability of adequately skilled workers and trained and qualified personnel for their export and fashion marketing departments has become one of the major issues. The new curricula that will be developed in the project will offer essential transversal skills for a quick and qualified response to the international trade and market demands and for enhancing the extroversion and the competitiveness of the fashion industry. The learning content will be tailored to the needs of export and fashion marketing personnel. The constitution of the partnership was based on the cooperation between education and employment in order to better achieve the objectives of the project. The project consortium includes six partners from five countries (Greece, Belgium, Romania, Spain and UK).
A distance limited method for sampling downed coarse woody debris
Jeffrey H. Gove; Mark J. Ducey; Harry T. Valentine; Michael S. Williams
2012-01-01
A new sampling method for down coarse woody debris is proposed based on limiting the perpendicular distance from individual pieces to a randomly chosen sample point. Two approaches are presented that allow different protocols to be used to determine field measurements; estimators for each protocol are also developed. Both protocols are compared via simulation against...
Quantum cryptography without switching.
Weedbrook, Christian; Lance, Andrew M; Bowen, Warwick P; Symul, Thomas; Ralph, Timothy C; Lam, Ping Koy
2004-10-22
We propose a new coherent state quantum key distribution protocol that eliminates the need to randomly switch between measurement bases. This protocol provides significantly higher secret key rates with increased bandwidths than previous schemes that only make single quadrature measurements. It also offers the further advantage of simplicity compared to all previous protocols which, to date, have relied on switching.
Reddy, Alavalapati Goutham; Das, Ashok Kumar; Odelu, Vanga; Yoo, Kee-Young
2016-01-01
Biometric based authentication protocols for multi-server architectures have gained momentum in recent times due to advancements in wireless technologies and associated constraints. Lu et al. recently proposed a robust biometric based authentication with key agreement protocol for a multi-server environment using smart cards. They claimed that their protocol is efficient and resistant to prominent security attacks. The careful investigation of this paper proves that Lu et al.'s protocol does not provide user anonymity, perfect forward secrecy and is susceptible to server and user impersonation attacks, man-in-middle attacks and clock synchronization problems. In addition, this paper proposes an enhanced biometric based authentication with key-agreement protocol for multi-server architecture based on elliptic curve cryptography using smartcards. We proved that the proposed protocol achieves mutual authentication using Burrows-Abadi-Needham (BAN) logic. The formal security of the proposed protocol is verified using the AVISPA (Automated Validation of Internet Security Protocols and Applications) tool to show that our protocol can withstand active and passive attacks. The formal and informal security analyses and performance analysis demonstrates that the proposed protocol is robust and efficient compared to Lu et al.'s protocol and existing similar protocols.
Evaluation of Patient Handoff Methods on an Inpatient Teaching Service
Craig, Steven R.; Smith, Hayden L.; Downen, A. Matthew; Yost, W. John
2012-01-01
Background The patient handoff process can be a highly variable and unstructured period at risk for communication errors. The morning sign-in process used by resident physicians at teaching hospitals typically involves less rigorous handoff protocols than the resident evening sign-out process. Little research has been conducted on best practices for handoffs during morning sign-in exchanges between resident physicians. Research must evaluate optimal protocols for the resident morning sign-in process. Methods Three morning handoff protocols consisting of written, electronic, and face-to-face methods were implemented over 3 study phases during an academic year. Study participants included all interns covering the internal medicine inpatient teaching service at a tertiary hospital. Study measures entailed intern survey-based interviews analyzed for failures in handoff protocols with or without missed pertinent information. Descriptive and comparative analyses examined study phase differences. Results A scheduled face-to-face handoff process had the fewest protocol deviations and demonstrated best communication of essential patient care information between cross-covering teams compared to written and electronic sign-in protocols. Conclusion Intern patient handoffs were more reliable when the sign-in protocol included scheduled face-to-face meetings. This method provided the best communication of patient care information and allowed for open exchanges of information. PMID:23267259
Performance comparison of token ring protocols for hard-real-time communication
NASA Technical Reports Server (NTRS)
Kamat, Sanjay; Zhao, Wei
1992-01-01
The ability to guarantee the deadlines of synchronous messages while maintaining a good aggregate throughput is an important consideration in the design of distributed real-time systems. In this paper, we study two token ring protocols, the priority driven protocol and the timed token protocol, for their suitability for hard real-time systems. Both these protocols use a token to control access to the transmission medium. In a priority driven protocol, messages are assigned priorities and the protocol ensures that messages are transmitted in the order of their priorities. Timed token protocols do not provide for priority arbitration but ensure that the maximum access delay for a station is bounded. For both protocols, we first derive the schedulability conditions under which the transmission deadlines of a given set of synchronous messages can be guaranteed. Subsequently, we use these schedulability conditions to quantitatively compare the average case behavior of the protocols. This comparison demonstrates that each of the protocols has its domain of superior performance and neither dominates the other for the entire range of operating conditions.
Bioindicators in the MIDUS National Study: Protocol, Measures, Sample, and Comparative Context
Love, Gayle Dienberg; Seeman, Teresa E.; Weinstein, Maxine; Ryff, Carol D.
2010-01-01
Objectives MIDUS is a national study of health and aging among individuals aged 25 to 74 at baseline(1995/96). Longitudinal survey assessments (2004/05), were followed by biological assessments on a subsample aged 35–85. To facilitate public use, we describe the protocol, measures, and sample. Methods Respondents traveled to clinics for a two-day data collection protocol that included fasting blood specimens, 12-hour urine specimen, medical history, physical exam, bone densitometry, a laboratory challenge (heart rate variability, blood pressure, respiration, salivary cortisol). Results Response rates for the biological protocol (N = 1,255) were 39.3%, or 43.1% (adjusting for those who could not be located or contacted). Reasons for non-participation were travel, family obligations, and being too busy. Respondents were comparable to the recruitment pool on most demographic characteristics and health assessments. Discussion Strengths of the protocol vis-à-vis other similar studies include opportunities to link biological factors with diverse content from other MIDUS projects. PMID:20876364
NASA Astrophysics Data System (ADS)
Xu, Ling; Zhao, Zhiwen
2017-08-01
A new quantum protocol with the assistance of a semi-honest third party (TP) is proposed, which allows the participants comparing the equality of their private information without disclosing them. Different from previous protocols, this protocol utilizes quantum key distribution against the collective-dephasing noise and the collective-rotation noise, which is more robust and abandons few samples, to transmit the classical information. In addition, this protocol utilizes the GHZ-like state and the χ + state to produce the entanglement swapping. And the Bell basis and the dual basis are used to measure the particle pair so that 3 bits of each participant's private information can be compared in each comparison time, which is more efficient and consumes fewer comparison times. Meanwhile, there is no need of unitary operation and hash function in this protocol. At the end, various kinds of outside attack and participant attack are discussed and analyzed to be invalid, so it can complete the comparison in security.
Sheehan, Barbara; Stetson, Peter; Bhatt, Ashish R; Field, Adele I; Patel, Chirag; Maisel, James Mark
2016-01-01
Background The process of documentation in electronic health records (EHRs) is known to be time consuming, inefficient, and cumbersome. The use of dictation coupled with manual transcription has become an increasingly common practice. In recent years, natural language processing (NLP)–enabled data capture has become a viable alternative for data entry. It enables the clinician to maintain control of the process and potentially reduce the documentation burden. The question remains how this NLP-enabled workflow will impact EHR usability and whether it can meet the structured data and other EHR requirements while enhancing the user’s experience. Objective The objective of this study is evaluate the comparative effectiveness of an NLP-enabled data capture method using dictation and data extraction from transcribed documents (NLP Entry) in terms of documentation time, documentation quality, and usability versus standard EHR keyboard-and-mouse data entry. Methods This formative study investigated the results of using 4 combinations of NLP Entry and Standard Entry methods (“protocols”) of EHR data capture. We compared a novel dictation-based protocol using MediSapien NLP (NLP-NLP) for structured data capture against a standard structured data capture protocol (Standard-Standard) as well as 2 novel hybrid protocols (NLP-Standard and Standard-NLP). The 31 participants included neurologists, cardiologists, and nephrologists. Participants generated 4 consultation or admission notes using 4 documentation protocols. We recorded the time on task, documentation quality (using the Physician Documentation Quality Instrument, PDQI-9), and usability of the documentation processes. Results A total of 118 notes were documented across the 3 subject areas. The NLP-NLP protocol required a median of 5.2 minutes per cardiology note, 7.3 minutes per nephrology note, and 8.5 minutes per neurology note compared with 16.9, 20.7, and 21.2 minutes, respectively, using the Standard-Standard protocol and 13.8, 21.3, and 18.7 minutes using the Standard-NLP protocol (1 of 2 hybrid methods). Using 8 out of 9 characteristics measured by the PDQI-9 instrument, the NLP-NLP protocol received a median quality score sum of 24.5; the Standard-Standard protocol received a median sum of 29; and the Standard-NLP protocol received a median sum of 29.5. The mean total score of the usability measure was 36.7 when the participants used the NLP-NLP protocol compared with 30.3 when they used the Standard-Standard protocol. Conclusions In this study, the feasibility of an approach to EHR data capture involving the application of NLP to transcribed dictation was demonstrated. This novel dictation-based approach has the potential to reduce the time required for documentation and improve usability while maintaining documentation quality. Future research will evaluate the NLP-based EHR data capture approach in a clinical setting. It is reasonable to assert that EHRs will increasingly use NLP-enabled data entry tools such as MediSapien NLP because they hold promise for enhancing the documentation process and end-user experience. PMID:27793791
Xrootd in dCache - design and experiences
NASA Astrophysics Data System (ADS)
Behrmann, Gerd; Ozerov, Dmitry; Zangerl, Thomas
2011-12-01
dCache is a well established distributed storage solution used in both high energy physics computing and other disciplines. An overview of the implementation of the xrootd data access protocol within dCache is presented. The performance of various access mechanisms is studied and compared and it is concluded that our implementation is as perfomant as other protocols. This makes dCache a compelling alternative to the Scalla software suite implementation of xrootd, with added value from broad protocol support, including the IETF approved NFS 4.1 protocol.
NASA Astrophysics Data System (ADS)
Gao, Gan; Wang, Li-Ping
2010-11-01
We propose a quantum secret sharing protocol, in which Bell states in the high dimension Hilbert space are employed. The biggest advantage of our protocol is the high source capacity. Compared with the previous secret sharing protocol, ours has the higher controlling efficiency. In addition, as decoy states in the high dimension Hilbert space are used, we needn’t destroy quantum entanglement for achieving the goal to check the channel security.
DiLuigi, Andrea J; Engmann, Lawrence; Schmidt, David W; Benadiva, Claudio A; Nulsen, John C
2011-06-30
We performed a randomized trial to compare IVF outcomes in 54 poor responder patients undergoing a microdose leuprolide acetate (LA) protocol or a GnRH antagonist protocol incorporating a luteal phase E(2) patch and GnRH antagonist in the preceding menstrual cycle. Cancellation rates, number of oocytes retrieved, clinical pregnancy rates (PR), and ongoing PRs were similar between the two groups. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
A Study of Shared-Memory Mutual Exclusion Protocols Using CADP
NASA Astrophysics Data System (ADS)
Mateescu, Radu; Serwe, Wendelin
Mutual exclusion protocols are an essential building block of concurrent systems: indeed, such a protocol is required whenever a shared resource has to be protected against concurrent non-atomic accesses. Hence, many variants of mutual exclusion protocols exist in the shared-memory setting, such as Peterson's or Dekker's well-known protocols. Although the functional correctness of these protocols has been studied extensively, relatively little attention has been paid to their non-functional aspects, such as their performance in the long run. In this paper, we report on experiments with the performance evaluation of mutual exclusion protocols using Interactive Markov Chains. Steady-state analysis provides an additional criterion for comparing protocols, which complements the verification of their functional properties. We also carefully re-examined the functional properties, whose accurate formulation as temporal logic formulas in the action-based setting turns out to be quite involved.
Dirandeh, E
2014-10-01
The objective was to compare fertility in cows using an Ovsynch protocol starting on day 6 of first postpartum estrous cycle with an Ovsynch protocol initiated at random stages of the estrous cycle during heat stress (temperature-humidity index (THI)=77-83). Cows (n=459) at the beginning of the lactation period were randomly assigned to time-of-ovulation synchronization treatments: (1) control, Ovsynch (first GnRH treatment, PGF2α treatment 7 days later, second GnRH treatment 56 h later, and TAI 16 h later), initiated at random stages of the estrous cycle (40 ± 2 days postpartum, n=224) and (2) Ovsynch initiated on day 6 of first postpartum estrous cycle (estrus=day 0) based on detection of the first estrus after day 30 postpartum (O6, 35 ± 2 postpartum, n=235). Statistical analyses were conducted using SAS. The percentage of cows responding to the initial GnRH injection using the Ovsynch protocol was greater with the O6 treatment compared to the control treatment (60.4% compared with 52.6%). The percentage of cows having a corpus luteum (CL) on the day of the PGF2α injection was not different among treatments (control=87.0% and O6=90.2%, respectively). Also more cows in the O6 treatment group responded to the second GnRH injection of the Ovsynch protocol compared with control treatments (82.5% compared with 75.8%). Treatment affected the percentage of cows diagnosed pregnant at 32 ± 0.7 days and 60 ± 3 days after the resynchronized timing of AI but pregnancy losses (5.3% compared with 6.8%) did not differ between treatment groups. It is concluded that initiating the Ovsynch protocol 6 days after estrus during the first 40 days postpartum resulted in a greater pregnancy rate at the synchronized estrus and increased fertility compared with control cows during heat stress. Copyright © 2014 Elsevier B.V. All rights reserved.
Iwakiri, Kentaro; Kobayashi, Akio; Seki, Masahiko; Ando, Yoshiyuki; Tsujio, Tadao; Hoshino, Masatoshi; Nakamura, Hiroaki
2017-11-15
MINI: Fourteen hundred consecutive patients were investigated for evaluating the utility of waterless hand rub before orthopaedic surgery. The risk in the surgical site infection incidence was the same, but costs of liquids used for hand hygiene were cheaper and the hand hygiene time was shorter for waterless protocol, compared with traditional hand scrub. A retrospective cohort study with prospectively collected data. The aim of this study was to compare SSI incidences, the cost of hand hygiene agents, and hand hygiene time between the traditional hand scrub and the waterless hand rub protocols before orthopedic surgery. Surgical site infections (SSI) prolong hospitalization and are a leading nosocomial cause of morbidity and a source of excess cost. Recently, a waterless hand rub protocol comprising alcohol based chlorhexidine gluconate for use before surgery was developed, but no studies have yet examined its utility in orthopedic surgery. Fourteen hundred consecutive patients who underwent orthopedic surgery (spine, joint replacement, hand, and trauma surgeries) in our hospital since April 1, 2012 were included. A total of 712 cases underwent following traditional hand scrub between April 1, 2012 and April 30, 2013 and 688 cases underwent following waterless hand rub between June 1, 2013 and April 30, 2014. We compared SSI incidences within all and each subcategory between two hand hygiene protocols. All patients were screened for SSI within 1 year after surgery. We compared the cost of hand hygiene agents and hand hygiene time between two groups. The SSI incidences were 1.3% (9 of 712) following the traditional protocol (2 deep and 7 superficial infections) and 1.1% (8 of 688) following the waterless protocol (all superficial infections). There were no significant differences between the two groups. The costs of liquids used for one hand hygiene were about $2 for traditional hand scrub and less than $1 for waterless hand rub. The mean hand hygiene time was 264 seconds with the traditional protocol and 160 seconds with the waterless protocol. Waterless hand rub with an alcohol based chlorhexidine gluconate solution can be a safe, quick, and cost-effective alternative to traditional hand scrub. 3.
Brehmer, Jess L; Husband, Jeffrey B
2014-10-01
There are relatively few studies in the literature that specifically evaluate accelerated rehabilitation protocols for distal radial fractures treated with open reduction and internal fixation (ORIF). The purpose of this study was to compare the early postoperative outcomes (at zero to twelve weeks postoperatively) of patients enrolled in an accelerated rehabilitation protocol with those of patients enrolled in a standard rehabilitation protocol following ORIF for a distal radial fracture. We hypothesized that patients with accelerated rehabilitation after volar ORIF for a distal radial fracture would have an earlier return to function compared with patients who followed a standard protocol. From November 2007 to November 2010, eighty-one patients with an unstable distal radial fracture were prospectively randomized to follow either an accelerated or a standard rehabilitation protocol after undergoing ORIF with a volar plate for a distal radial fracture. Both groups began with gentle active range of motion at three to five days postoperatively. At two weeks, the accelerated group initiated wrist/forearm passive range of motion and strengthening exercises, whereas the standard group initiated passive range of motion and strengthening at six weeks postoperatively. Patients were assessed at three to five days, two weeks, three weeks, four weeks, six weeks, eight weeks, twelve weeks, and six months postoperatively. Outcomes included Disabilities of the Arm, Shoulder and Hand (DASH) scores (primary outcome) and measurements of wrist flexion/extension, supination, pronation, grip strength, and palmar pinch. The patients in the accelerated group had better mobility, strength, and DASH scores at the early postoperative time points (zero to eight weeks postoperatively) compared with the patients in the standard rehabilitation group. The difference between the groups was both clinically relevant and statistically significant. Patients who follow an accelerated rehabilitation protocol that emphasizes motion immediately postoperatively and initiates strengthening at two weeks after volar ORIF of a distal radial fracture have an earlier return to function than patients who follow a more standard rehabilitation protocol. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Neuromuscular Fatigue and Physiological Responses After Five Dynamic Squat Exercise Protocols.
Raeder, Christian; Wiewelhove, Thimo; Westphal-Martinez, Marc P; Fernandez-Fernandez, Jaime; de Paula Simola, Rauno A; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander
2016-04-01
This aimed to analyze neuromuscular, physiological and perceptual responses to a single bout of 5 different dynamic squat exercise protocols. In a randomized and counterbalanced order, 15 male resistance-trained athletes (mean ± SD; age: 23.1 ± 1.9 years, body mass: 77.4 ± 8.0 kg) completed traditional multiple sets (MS: 4 × 6, 85% 1 repetition maximum [RM]), drop sets (DS: 1 × 6, 85% 1RM + 3 drop sets), eccentric overload (EO: 4 × 6, 70% 1RM concentric, 100% 1RM eccentric), flywheel YoYo squat (FW: 4 × 6, all-out), and a plyometric jump protocol (PJ: 4 × 15, all-out). Blood lactate (La), ratings of perceived exertion (RPE), counter movement jump height (CMJ), multiple rebound jump (MRJ) performance, maximal voluntary isometric contraction force, serum creatine kinase (CK) and delayed onset muscle soreness were measured. Immediately post exercise, La was significantly (p < 0.001) higher in FW (mean ± 95% confidence limit; 12.2 ± 0.9 mmol·L) and lower in PJ (3.0 ± 0.8 mmol·L) compared with MS (7.7 ± 1.5 mmol·L), DS (8.5 ± 0.6 mmol·L), and EO (8.2 ± 1.6 mmol·L), accompanied by similar RPE responses. Neuromuscular performance (CMJ, MRJ) significantly remained decreased (p < 0.001) from 0.5 to 48 hours post exercise in all protocols. There was a significant time × protocol interaction (p ≤ 0.05) in MRJ with a significant lower performance in DS, EO, and FW compared with PJ (0.5 hours post exercise), and in EO compared with all other protocols (24 hours post exercise). A significant main time effect with peak values 24 hours post exercise was observed in CK serum concentrations (p < 0.001), but there was no time × protocol interaction. In conclusion, (a) metabolic and perceptual demands were higher in FW and EO compared with MS, DS and PJ, (b) neuromuscular fatigue was consistent up to 48 hours post exercise in all protocols, and (c) EO induced the greatest neuromuscular fatigue.
Cho, Eun-Suk; Kim, Joo Hee; Kim, Sungjun; Yu, Jeong-Sik; Chung, Jae-Joon; Yoon, Choon-Sik; Lee, Hyeon-Kyeong; Lee, Kyung Hee
2012-01-01
To prospectively investigate the feasibility of an 80-kilovolt (peak) (kVp) protocol in computed tomographic venography for varicose veins of the lower extremities by comparison with conventional 120-kVp protocol. Attenuation values and signal-to-noise ratio of iodine contrast medium (CM) were determined in a water phantom for 2 tube voltages (80 kVp and 120 kVp). Among 100 patients, 50 patients were scanned with 120 kVp and 150 effective milliampere second (mAs(eff)), and the other 50 patients were scanned with 80 kVp and 390 mAs(eff) after the administration of 1.7-mL/kg CM (370 mg of iodine per milliliter). The 2 groups were compared for venous attenuation, contrast-to-noise ratio, and subjective degree of venous enhancement, image noise, and overall diagnostic image quality. In the phantom, the attenuation value and signal-to-noise ratio value for iodine CM at 80 kVp were 63.8% and 33.0% higher, respectively, than those obtained at 120 kVp. The mean attenuation of the measured veins of the lower extremities was 148.3 Hounsfield units (HU) for the 80-kVp protocol and 94.8 HU for the 120-kVp protocol. Contrast-to-noise ratio was also significantly higher with the 80-kVp protocol. The overall diagnostic image quality of the 3-dimensional volume-rendered images was good with both protocols. The subjective score for venous enhancement was higher at the 80-kVp protocol. The mean volume computed tomography dose index of the 80-kVp (5.6 mGy) protocol was 23.3% lower than that of the 120-kVp (7.3 mGy) protocol. The use of the 80-kVp protocol improved overall venous attenuation, especially in perforating vein, and provided similarly high diagnostic image quality with a lower radiation dose when compared to the conventional 120-kVp protocol.
Campagne, Fabien
2008-02-29
The evaluation of information retrieval techniques has traditionally relied on human judges to determine which documents are relevant to a query and which are not. This protocol is used in the Text Retrieval Evaluation Conference (TREC), organized annually for the past 15 years, to support the unbiased evaluation of novel information retrieval approaches. The TREC Genomics Track has recently been introduced to measure the performance of information retrieval for biomedical applications. We describe two protocols for evaluating biomedical information retrieval techniques without human relevance judgments. We call these protocols No Title Evaluation (NT Evaluation). The first protocol measures performance for focused searches, where only one relevant document exists for each query. The second protocol measures performance for queries expected to have potentially many relevant documents per query (high-recall searches). Both protocols take advantage of the clear separation of titles and abstracts found in Medline. We compare the performance obtained with these evaluation protocols to results obtained by reusing the relevance judgments produced in the 2004 and 2005 TREC Genomics Track and observe significant correlations between performance rankings generated by our approach and TREC. Spearman's correlation coefficients in the range of 0.79-0.92 are observed comparing bpref measured with NT Evaluation or with TREC evaluations. For comparison, coefficients in the range 0.86-0.94 can be observed when evaluating the same set of methods with data from two independent TREC Genomics Track evaluations. We discuss the advantages of NT Evaluation over the TRels and the data fusion evaluation protocols introduced recently. Our results suggest that the NT Evaluation protocols described here could be used to optimize some search engine parameters before human evaluation. Further research is needed to determine if NT Evaluation or variants of these protocols can fully substitute for human evaluations.
Michaelowa, A; Rolfe, C
2001-09-01
Current "business as usual" projections suggest greenhouse gas emissions from industrialized nations will grow substantially over the next decade. However, if it comes into force, the Kyoto Protocol will require industrialized nations to reduce emissions to an average of 5% below 1990 levels in the 2008-2012 period. Taking early action to close this gap has a number of advantages. It reduces the risks of passing thresholds that trigger climate change "surprises." Early action also increases future generations' ability to choose greater levels of climate protection, and it leads to faster reductions of other pollutants. From an economic sense, early action is important because it allows shifts to less carbon-intensive technologies during the course of normal capital stock turnover. Moreover, many options for emission reduction have negative costs, and thus are economically worthwhile, because of paybacks in energy costs, healthcare costs, and other benefits. Finally, early emission reductions enhance the probability of successful ratification and lower the risk of noncompliance with the protocol. We discuss policy approaches for the period prior to 2008. Disadvantages of the current proposals for Credit for Early Action are the possibility of adverse selection due to problematic baseline calculation methods as well as the distributionary impacts of allocating a part of the emissions budget already before 2008. One simple policy without drawbacks is the so-called baseline protection, which removes the disincentive to early action due to the expectation that businesses may, in the future, receive emission rights in proportion to past emissions. It is particularly important to adopt policies that shift investment in long-lived capital stock towards less carbon-intensive technologies and to encourage innovation and technology development that will reduce future compliance costs.
2014-01-01
The methylation of cytosine to 5-methylcytosine (5-meC) is an important epigenetic DNA modification in many bacteria, plants, and mammals, but its relevance for important model organisms, including Caenorhabditis elegans and Drosophila melanogaster, is still equivocal. By reporting the presence of 5-meC in a broad variety of wild, laboratory, and industrial yeasts, a recent study also challenged the dogma about the absence of DNA methylation in yeast species. We would like to bring to attention that the protocol used for gas chromatography/mass spectrometry involved hydrolysis of the DNA preparations. As this process separates cytosine and 5-meC from the sugar phosphate backbone, this method is unable to distinguish DNA- from RNA-derived 5-meC. We employed an alternative LC–MS/MS protocol where by targeting 5-methyldeoxycytidine moieties after enzymatic digestion, only 5-meC specifically derived from DNA is quantified. This technique unambiguously identified cytosine DNA methylation in Arabidopsis thaliana (14.0% of cytosines methylated), Mus musculus (7.6%), and Escherichia coli (2.3%). Despite achieving a detection limit at 250 attomoles (corresponding to <0.00002 methylated cytosines per nonmethylated cytosine), we could not confirm any cytosine DNA methylation in laboratory and industrial strains of Saccharomyces cerevisiae, Schizosaccharomyces pombe, Saccharomyces boulardii, Saccharomyces paradoxus, or Pichia pastoris. The protocol however unequivocally confirmed DNA methylation in adult Drosophila melanogaster at a value (0.034%) that is up to 2 orders of magnitude below the detection limit of bisulphite sequencing. Thus, 5-meC is a rare DNA modification in drosophila but absent in yeast. PMID:24640988
Traffic Light Protocol for Induced Seismicity: What is the Best Strategy?
NASA Astrophysics Data System (ADS)
Kao, H.; Mahani, A. B.; Atkinson, G. M.; Eaton, D. W. S.; Maxwell, S.
2015-12-01
In response to the occurrence of relatively large (and felt) earthquakes that are potentially induced by man-made activities, there is an increasing trend for the industry and government regulators to include a "traffic light" system in their decision-making process. Despite its tremendous implications to the cost of operations and the protection of public safety, the protocol that defines the different scenarios for different lights ("green", "yellow", or "red") has not been thoroughly validated to truly reflect the associated seismic risk. Most government regulators adopt a traffic light protocol (TLP) that depends on the magnitude of the earthquake of interest and sometimes felt reports from local communities. It is well known that the estimate of an earthquake's magnitude can have some uncertainty. While an uncertainty of +/-0.2 in magnitude is understandable and generally accepted by the seismological community, it can create a serious problem when the value of magnitude is the predominant factor in the TLP for induced seismicity. Recent examples of magnitude 4 and larger earthquakes in northeast BC and western AB that are possibly induced by shale gas hydraulic fracturing have demonstrated vividly the possible deficiency of existing TLP for induced seismicity. From the viewpoint of mitigating seismic risk, we argue that a ground-motion based TLP should be more effective than a magnitude-based approach. A workshop with representatives from government agencies, the industry, and the academia will be held to review the deficiency of the current TLP for induced seismicity and to explore innovative ways of improvement. The ultimate goal of the TLP for induced seismicity is to reach a balance between the protection of public safety and the economic benefit of developing natural resources In this presentation, main conclusions of this workshop will be presented.
Designing Endocrine Disruption Out of the Next Generation of Chemicals
Schug, T.T; Abagyan, R.; Blumberg, B.; Collins, T.J.; Crews, D.; DeFur, P.L.; Dickerson, S.M.; Edwards, T.M.; Gore, A.C.; Guillette, L.J.; Hayes, T.; Heindel, J.J.; Moores, A.; Patisaul, H.B.; Tal, T.L.; Thayer, K.A.; Vandenberg, L.N.; Warner, J.; Watson, C.S.; Saal, F.S. vom; Zoeller, R.T.; O’Brien, K.P.; Myers, J.P.
2013-01-01
A central goal of green chemistry is to avoid hazard in the design of new chemicals. This objective is best achieved when information about a chemical’s potential hazardous effects is obtained as early in the design process as feasible. Endocrine disruption is a type of hazard that to date has been inadequately addressed by both industrial and regulatory science. To aid chemists in avoiding this hazard, we propose an endocrine disruption testing protocol for use by chemists in the design of new chemicals. The Tiered Protocol for Endocrine Disruption (TiPED) has been created under the oversight of a scientific advisory committee composed of leading representatives from both green chemistry and the environmental health sciences. TiPED is conceived as a tool for new chemical design, thus it starts with a chemist theoretically at “the drawing board.” It consists of five testing tiers ranging from broad in silico evaluation up through specific cell- and whole organism-based assays. To be effective at detecting endocrine disruption, a testing protocol must be able to measure potential hormone-like or hormone-inhibiting effects of chemicals, as well as the many possible interactions and signaling sequellae such chemicals may have with cell-based receptors. Accordingly, we have designed this protocol to broadly interrogate the endocrine system. The proposed protocol will not detect all possible mechanisms of endocrine disruption, because scientific understanding of these phenomena is advancing rapidly. To ensure that the protocol remains current, we have established a plan for incorporating new assays into the protocol as the science advances. In this paper we present the principles that should guide the science of testing new chemicals for endocrine disruption, as well as principles by which to evaluate individual assays for applicability, and laboratories for reliability. In a ‘proof-of-principle’ test, we ran 6 endocrine disrupting chemicals (EDCs) that act via different endocrinological mechanisms through the protocol using published literature. Each was identified as endocrine active by one or more tiers. We believe that this voluntary testing protocol will be a dynamic tool to facilitate efficient and early identification of potentially problematic chemicals, while ultimately reducing the risks to public health. PMID:25110461
Designing Endocrine Disruption Out of the Next Generation of Chemicals.
Schug, T T; Abagyan, R; Blumberg, B; Collins, T J; Crews, D; DeFur, P L; Dickerson, S M; Edwards, T M; Gore, A C; Guillette, L J; Hayes, T; Heindel, J J; Moores, A; Patisaul, H B; Tal, T L; Thayer, K A; Vandenberg, L N; Warner, J; Watson, C S; Saal, F S Vom; Zoeller, R T; O'Brien, K P; Myers, J P
2013-01-01
A central goal of green chemistry is to avoid hazard in the design of new chemicals. This objective is best achieved when information about a chemical's potential hazardous effects is obtained as early in the design process as feasible. Endocrine disruption is a type of hazard that to date has been inadequately addressed by both industrial and regulatory science. To aid chemists in avoiding this hazard, we propose an endocrine disruption testing protocol for use by chemists in the design of new chemicals. The Tiered Protocol for Endocrine Disruption (TiPED) has been created under the oversight of a scientific advisory committee composed of leading representatives from both green chemistry and the environmental health sciences. TiPED is conceived as a tool for new chemical design, thus it starts with a chemist theoretically at "the drawing board." It consists of five testing tiers ranging from broad in silico evaluation up through specific cell- and whole organism-based assays. To be effective at detecting endocrine disruption, a testing protocol must be able to measure potential hormone-like or hormone-inhibiting effects of chemicals, as well as the many possible interactions and signaling sequellae such chemicals may have with cell-based receptors. Accordingly, we have designed this protocol to broadly interrogate the endocrine system. The proposed protocol will not detect all possible mechanisms of endocrine disruption, because scientific understanding of these phenomena is advancing rapidly. To ensure that the protocol remains current, we have established a plan for incorporating new assays into the protocol as the science advances. In this paper we present the principles that should guide the science of testing new chemicals for endocrine disruption, as well as principles by which to evaluate individual assays for applicability, and laboratories for reliability. In a 'proof-of-principle' test, we ran 6 endocrine disrupting chemicals (EDCs) that act via different endocrinological mechanisms through the protocol using published literature. Each was identified as endocrine active by one or more tiers. We believe that this voluntary testing protocol will be a dynamic tool to facilitate efficient and early identification of potentially problematic chemicals, while ultimately reducing the risks to public health.
Ocean fertilization, carbon credits and the Kyoto Protocol
NASA Astrophysics Data System (ADS)
Westley, M. B.; Gnanadesikan, A.
2008-12-01
Commercial interest in ocean fertilization as a carbon sequestration tool was excited by the December 1997 agreement of the Kyoto Protocol to the United Nations Convention on Climate Change. The Protocol commits industrialized countries to caps on net greenhouse gas emissions and allows for various flexible mechanisms to achieve these caps in the most economically efficient manner possible, including trade in carbon credits from projects that reduce emissions or enhance sinks. The carbon market was valued at 64 billion in 2007, with the bulk of the trading (50 billion) taking place in the highly regulated European Union Emission Trading Scheme, which deals primarily in emission allowances in the energy sector. A much smaller amount, worth $265 million, was traded in the largely unregulated "voluntary" market (Capoor and Ambrosi 2008). As the voluntary market grows, so do calls for its regulation, with several efforts underway to set rules and standards for the sale of voluntary carbon credits using the Kyoto Protocol as a starting point. Four US-based companies and an Australian company currently seek to develop ocean fertilization technologies for the generation of carbon credits. We review these plans through the lens of the Kyoto Protocol and its flexible mechanisms, and examine whether and how ocean fertilization could generate tradable carbon credits. We note that at present, ocean sinks are not included in the Kyoto Protocol, and that furthermore, the Kyoto Protocol only addresses sources and sinks of greenhouse gases within national boundaries, making open-ocean fertilization projects a jurisdictional challenge. We discuss the negotiating history behind the limited inclusion of land use, land use change and forestry in the Kyoto Protocol and the controversy and eventual compromise concerning methodologies for terrestrial carbon accounting. We conclude that current technologies for measuring and monitoring carbon sequestration following ocean fertilization are unlikely to meet the Kyoto Protocol's verification and accounting standards for trading carbon credits on the regulated market. The marketability of ocean fertilization in the voluntary carbon marketplace will likely depend on companies' efforts to minimize environmental risks and consumers' willingness to accept remaining risks.
Choukroun, J; Ghanaati, S
2018-02-01
The aim of this study was to analyze systematically the influence of the relative centrifugation force (RCF) on leukocytes, platelets and growth factor release within fluid platelet-rich fibrin matrices (PRF). Systematically using peripheral blood from six healthy volunteers, the RCF was reduced four times for each of the three experimental protocols (I-III) within the spectrum (710-44 g), while maintaining a constant centrifugation time. Flow cytometry was applied to determine the platelets and leukocyte number. The growth factor concentration was quantified 1 and 24 h after clotting using ELISA. Reducing RCF in accordance with protocol-II (177 g) led to a significantly higher platelets and leukocytes numbers compared to protocol-I (710 g). Protocol-III (44 g) showed a highly significant increase of leukocytes and platelets number in comparison to -I and -II. The growth factors' concentration of VEGF and TGF-β1 was significantly higher in protocol-II compared to -I, whereas protocol-III exhibited significantly higher growth factor concentration compared to protocols-I and -II. These findings were observed among 1 and 24 h after clotting, as well as the accumulated growth factor concentration over 24 h. Based on the results, it has been demonstrated that it is possible to enrich PRF-based fluid matrices with leukocytes, platelets and growth factors by means of a single alteration of the centrifugation settings within the clinical routine. We postulate that the so-called low speed centrifugation concept (LSCC) selectively enriches leukocytes, platelets and growth factors within fluid PRF-based matrices. Further studies are needed to evaluate the effect of cell and growth factor enrichment on wound healing and tissue regeneration while comparing blood concentrates gained by high and low RCF.