Cost and acceptability of three syringe-pump infusion systems.
Johnson, M S; Pesko, L J; Wood, C F; Reinders, T P
1990-08-01
The fiscal impact and acceptability of implementing a syringe-pump infusion system at a 900-bed university teaching hospital where the minibag system has been in use is reported. Researchers selected three models of syringe pumps for evaluation: the Bard Harvard Mini-Infuser 150XL, the Becton Dickinson 360 Infuser, and the Strato Stratofuse System. Each pump was evaluated for three weeks on a medical-surgical unit and a hematology-oncology unit. Drugs to be infused were chosen after a literature review to determine which drugs had been successfully infused via syringe pump; 22 formulary medications were selected. Syringes were prepared as singly packaged doses or as doses prepared in bulk and packaged frozen. Control of the syringe pumps and microbore tubing was assigned to the inpatient pharmacy staff. Nurses and pharmacy personnel were apprised of the study and taught how to use the syringe pumps. Time-and-motion studies were performed in the sterile products preparation area, and a cost analysis was done. Nurses preferred syringe pumps over the minibag system because the pumps reduced the nursing time needed to infuse a drug, administered less fluid, provided consistent infusion rates, had alarms, and were relatively easy to use. The time required to prepare syringes did not differ substantially among syringe-pump models. It was estimated that using any of the evaluated pumps in place of the minibag system would save $126,500 during the three-year period 1988-91, primarily because of differences in the cost of disposable items. The syringe-pump infusion system is an acceptable and cost-effective alternative to the minibag system.
A computerized system to evaluate volumetric infusion pumps.
Kobayashi, S; Ogata, T
1992-01-01
A computerized system was developed to examine the performance characteristics of infusion pumps. This system collects solution delivered by an infusion pump through an intravenous needle into a collection vessel. Using an inductor-type weight sensor and a semiconductor type of strain-gauge pressure sensor, the weight of the collection vessel and the pressure at the needle were monitored over a specific period (the sampling time), and changes in pressure, flow rate, and volume of fluid were calculated. This system was applied to five volumetric infusion pumps with different pumping mechanisms. Test conditions involved two different solutions, two sizes of needle gauge, and seven flow rates, for a total of 28 measurements per pump. Results showed considerable variation in the infusion pumps' performances based on differences in these indices. Use of an inductance weight sensor as a means to evaluate gravimetric performance appears to be an improvement over conventional methods, which use analytical balances for data generation. The results indicate that this system will be useful in evaluating the performances of commercially available infusion pumps as well as those in development.
76 FR 8637 - Medical Devices; Medical Device Data Systems
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-15
... would alter the parameters on an infusion pump. The MDDS could pass that control signal to the infusion... proposed Sec. 880.6310(a). Commenters also asked whether a system that sends data to an infusion pump to... signal to an infusion pump to control the flow rate would not be an MDDS because, as the revised final...
Using higher doses to compensate for tubing residuals in extended-infusion piperacillin-tazobactam.
Lam, Wendy J; Bhowmick, Tanaya; Gross, Alan; Vanschooneveld, Trevor C; Weinstein, Melvin P
2013-06-01
To mathematically assess drug losses due to infusion line residuals and evaluate methods to compensate for drug loss due to residual volumes in intravenous pump tubing. Literature was accessed through Ovid MEDLINE (1996-February 2013), using combinations of the search terms tubing residuals, residual volume, residual medication, intravenous infusions, intravenous injections, piperacillin, piperacillin-tazobactam, β-lactams, equipment design, infusion pumps, extended infusion, extended administration, and prolonged infusion. In addition, select reference citations from publications identified were reviewed. All articles that involved extended-infusion piperacillin-tazobactam implementation strategies were included in the review. Infusion pump characteristics and tubing residuals can affect extended-infusion piperacillin-tazobactam dosing strategies. Two studies addressing tubing residuals were identified. Both studies recommended increasing infusion volumes to compensate for tubing residuals. One study also recommended decreasing infusion-line dead space by using alternative infusion pump systems. Study calculations suggest that higher doses of piperacillin-tazobactam may be used to account for medication left in tubing residuals if alternative infusion pump systems cannot be obtained, and increased infusion volumes are not an option. Extended-infusion piperacillin-tazobactam has been used as a method of maximizing pharmacodynamic target attainment. Use of higher doses of piperacillin-tazobactam may be a reasonable method to compensate for drug loss due to residual volumes in large-bore intravenous pump tubing.
Smart syringe pumps for drug infusion during dental intravenous sedation
Lee, Kiyoung
2016-01-01
Dentists often sedate patients in order to reduce their dental phobia and stress during dental treatment. Sedatives are administered through various routes such as oral, inhalation, and intravenous routes. Intravenous administration has the advantage of rapid onset of action, predictable duration of action, and easy titration. Typically, midazolam, propofol or dexmedetomidine are used as intravenous sedatives. Administration of these sedatives via infusion by using a syringe pump is more effective and successful than infusing them as a bolus. However, during intravenous infusion of sedatives or opioids using a syringe pump, fatal accidents may occur due to the clinician's carelessness. To prevent such risks, smart syringe pumps have been introduced clinically. They allow clinicians to perform effective sedation by using a computer to control the dose of the drug being infused. To ensure patient safety, various alarm features along with a drug library, which provides drug information and prevents excessive infusion by limiting the dose, have been added to smart pumps. In addition, programmed infusion systems and target-controlled infusion systems have also been developed to enable effective administration of sedatives. Patient-controlled infusion, which allows a patient to control his/her level of sedation through self-infusion, has also been developed. Safer and more successful sedation may be achieved by fully utilizing these new features of the smart pump. PMID:28884149
Dunford, Benjamin B; Perrigino, Matthew; Tucker, Sharon J; Gaston, Cynthia L; Young, Jim; Vermace, Beverly J; Walroth, Todd A; Buening, Natalie R; Skillman, Katherine L; Berndt, Dawn
2017-09-01
We investigated nurse perceptions of smart infusion medication pumps to provide evidence-based insights on how to help reduce work around and improve compliance with patient safety policies. Specifically, we investigated the following 3 research questions: (1) What are nurses' current attitudes about smart infusion pumps? (2) What do nurses think are the causes of smart infusion pump work arounds? and (3) To whom do nurses turn for smart infusion pump training and troubleshooting? We surveyed a large number of nurses (N = 818) in 3 U.S.-based health care systems to address the research questions above. We assessed nurses' opinions about smart infusion pumps, organizational perceptions, and the reasons for work arounds using a voluntary and anonymous Web-based survey. Using qualitative research methods, we coded open-ended responses to questions about the reasons for work arounds to organize responses into useful categories. The nurses reported widespread satisfaction with smart infusion pumps. However, they reported numerous organizational, cultural, and psychological causes of smart pump work arounds. Of 1029 open-ended responses to the question "why do smart pump work arounds occur?" approximately 44% of the causes were technology related, 47% were organization related, and 9% were related to individual factors. Finally, an overwhelming majority of nurses reported seeking solutions to smart pump problems from coworkers and being trained primarily on the job. Hospitals may significantly improve adherence to smart pump safety features by addressing the nontechnical causes of work arounds and by providing more leadership and formalized training for resolving smart pump-related problems.
Breadboard development of a fluid infusion system
NASA Technical Reports Server (NTRS)
Thompson, R. W.
1974-01-01
A functional breadboard of a zero gravity Intravenous Infusion System (IVI) is presented. Major components described are: (1) infusate pack pressurizers; (2) pump module; (3) infusion set; and (4) electronic control package. The IVI breadboard was designed to demonstrate the feasibility of using the parallel solenoid pump and spring powered infusate source pressurizers for the emergency infusion of various liquids in a zero gravity environment. The IVI was tested for flow rate and sensitivity to back pressure at the needle. Results are presented.
Effects of intravenous delivery systems on infused red blood cells.
Gibson, J S; Leff, R D; Roberts, R J
1984-03-01
The effects of various intravenous delivery systems on the integrity of infused red blood cells (RBCs) were studied. Using a factorial design, whole blood and packed RBCs were infused through i.v. delivery systems employing various combinations of i.v. tubing diameter and length, needle gauge, infusion rate (5 and 50 ml/hr), type of infusion pump (piston, diaphragm, or peristaltic operation), and type of blood product. The age and temperature of the blood filter used were held constant. A 5-ml sample of the blood product obtained during each experimental run was analyzed for plasma free-hemoglobin to assess the degree of hemolysis. Osmotic fragility of the RBCs was evaluated by measuring the percentage of hemolysis in the blood products in various concentrations of sodium chloride solution. Type of blood product and i.v. pump were the only variables significantly influencing RBC hemolysis. In both blood products, a greater degree of hemolysis occurred with the peristaltic-type pump than with the other types of pumps. In packed RBCs, the diaphragm-type pump produced greater hemolysis than the piston-type pump, but hemolysis was similar in whole-blood samples. Regardless of the type of pump, more hemolysis occurred in whole blood at the 5-ml/hr infusion rate than at the 50-ml/hr rate, but the converse was true in packed RBCs. Samples of both blood products were less osmotically fragile than their respective controls at sodium chloride concentrations ranging from 0.30 to 0.50%.(ABSTRACT TRUNCATED AT 250 WORDS)
Quality-improvement analytics for intravenous infusion pumps.
Skledar, Susan J; Niccolai, Cynthia S; Schilling, Dennis; Costello, Susan; Mininni, Nicolette; Ervin, Kelly; Urban, Alana
2013-04-15
The implementation of a smart-pump continuous quality-improvement (CQI) program across a large health system is described, with an emphasis on key metrics for outcomes analyses and program refinement. Three years ago, the University of Pittsburgh Medical Center health system launched a CQI initiative to help ensure the safe use of 6000 smart pumps in its 14 inpatient facilities. A centralized team led by pharmacists is responsible for the retrieval and interpretation of smart-pump data, which is continuously transmitted to a main server. CQI findings are regularly posted on the health system's interdisciplinary intranet. Monitored metrics include rates of compliance with preprogrammed infusion limits, the top 20 drugs involved in alerts, drugs associated with alert-override rates of ≥90%, numbers of alerts by infusion type, nurse responses to alerts, and alert rate per drug library update. Based on the collected CQI data and site-specific requests, four systemwide updates of the smart-pump drug library were performed during the first 18 months of the program, reducing "nuisance alerts" by about 10% per update cycle and enabling targeted interventions to reduce rapid-infusion errors, other adverse drug events (ADEs), and pump-programming workarounds. Over one 12-month period, bedside alerts prompted nurses to reprogram or cancel continuous infusions an average of 400 times per month, potentially averting i.v. medication ADEs. A smart-pump CQI program is an effective tool for enhancing the safety of i.v. medication administration. The ongoing refinement of the drug library through the development and implementation of key interventions promotes the growth and sustainability of the smart-pump initiative systemwide.
NASA Technical Reports Server (NTRS)
Fischell, Robert E. (Inventor)
1988-01-01
A medication infusion system having a means for providing an informational signal when (1) medication in the reservoir falls below a threshold level; (2) a fluid leak occurs in different portions of the system; and (3) the intended medication pumping does not correlate with the pumping actually affected.
Newswanger, Brett; Ammons, Steve; Phadnis, Neelima; Ward, W. Kenneth; Castle, Jessica; Campbell, Robert W.
2015-01-01
Background: Despite a vigorous research effort, to date, the development of systems that achieve glucagon stability in aqueous formulations (without reconstitution) has failed to produce any clinical candidates. We have developed a novel, nonaqueous glucagon formulation based on a biocompatible pharmaceutical solvent, dimethyl sulfoxide, which demonstrates excellent physical and chemical stability at relatively high concentrations and at high temperatures. Methods: This article reports the development of a novel, biocompatible, nonaqueous native human glucagon formulation for potential use in subcutaneous infusion pump systems. Results: Data are presented that demonstrate physical and chemical stability under presumed storage conditions (>2 years at room temperature) as well as “in use” stability and compatibility in an Insulet’s OmniPod® infusion pump. Also presented are results of a skin irritation study in a rabbit model and pharmacokinetics/pharmacodynamics data following pump administration of glucagon in a diabetic swine model. Conclusions: This nonaqueous glucagon formulation is suitable for further clinical development in pump systems. PMID:25550410
Newswanger, Brett; Ammons, Steve; Phadnis, Neelima; Ward, W Kenneth; Castle, Jessica; Campbell, Robert W; Prestrelski, Steven J
2015-01-01
Despite a vigorous research effort, to date, the development of systems that achieve glucagon stability in aqueous formulations (without reconstitution) has failed to produce any clinical candidates. We have developed a novel, nonaqueous glucagon formulation based on a biocompatible pharmaceutical solvent, dimethyl sulfoxide, which demonstrates excellent physical and chemical stability at relatively high concentrations and at high temperatures. This article reports the development of a novel, biocompatible, nonaqueous native human glucagon formulation for potential use in subcutaneous infusion pump systems. Data are presented that demonstrate physical and chemical stability under presumed storage conditions (>2 years at room temperature) as well as "in use" stability and compatibility in an Insulet's OmniPod(®) infusion pump. Also presented are results of a skin irritation study in a rabbit model and pharmacokinetics/pharmacodynamics data following pump administration of glucagon in a diabetic swine model. This nonaqueous glucagon formulation is suitable for further clinical development in pump systems. © 2015 Diabetes Technology Society.
Comparative analytics of infusion pump data across multiple hospital systems.
Catlin, Ann Christine; Malloy, William X; Arthur, Karen J; Gaston, Cindy; Young, James; Fernando, Sudheera; Fernando, Ruchith
2015-02-15
A Web-based analytics system for conducting inhouse evaluations and cross-facility comparisons of alert data generated by smart infusion pumps is described. The Infusion Pump Informatics (IPI) project, a collaborative effort led by research scientists at Purdue University, was launched in 2009 to provide advanced analytics and tools for workflow analyses to assist hospitals in determining the significance of smart-pump alerts and reducing nuisance alerts. The IPI system allows facility-specific analyses of alert patterns and trends, as well as cross-facility comparisons of alert data uploaded by more than 55 participating institutions using different types of smart pumps. Tools accessible through the IPI portal include (1) charts displaying aggregated or breakout data on the top drugs associated with alerts, numbers of alerts per device or care area, and override-to-alert ratios, (2) investigative reports that can be used to characterize and analyze pump-programming errors in a variety of ways (e.g., by drug, by infusion type, by time of day), and (3) "drill-down" workflow analytics enabling users to evaluate alert patterns—both internally and in relation to patterns at other hospitals—in a quick and efficient stepwise fashion. The formation of the IPI analytics system to support a community of hospitals has been successful in providing sophisticated tools for member facilities to review, investigate, and efficiently analyze smart-pump alert data, not only within a member facility but also across other member facilities, to further enhance smart pump drug library design. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
21 CFR 880.5725 - Infusion pump.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Infusion pump. 880.5725 Section 880.5725 Food and... Infusion pump. (a) Identification. An infusion pump is a device used in a health care facility to pump... means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an...
21 CFR 880.5725 - Infusion pump.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Infusion pump. 880.5725 Section 880.5725 Food and... Infusion pump. (a) Identification. An infusion pump is a device used in a health care facility to pump... means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an...
Types and Frequency of Infusion Pump Alarms: Protocol for a Retrospective Data Analysis.
Glover, Kevin R; Vitoux, Rachel R; Schuster, Catherine; Curtin, Christopher R
2018-06-14
The variety of alarms from all types of medical devices has increased from 6 to 40 in the last three decades, with today's most critically ill patients experiencing as many as 45 alarms per hour. Alarm fatigue has been identified as a critical safety issue for clinical staff that can lead to potentially dangerous delays or nonresponse to actionable alarms, resulting in serious patient injury and death. To date, most research on medical device alarms has focused on the nonactionable alarms of physiological monitoring devices. While there have been some reports in the literature related to drug library alerts during the infusion pump programing sequence, research related to the types and frequencies of actionable infusion pump alarms remains largely unexplored. The objectives of this study protocol are to establish baseline data related to the types and frequency of infusion pump alarms from the B. Braun Outlook 400ES Safety Infusion System with the accompanying DoseTrac Infusion Management Software. The most recent consecutive 60-day period of backup hospital data received between April 2014 and February 2017 from 32 United States-based hospitals will be selected for analysis. Microsoft SQL Server (2012 - 11.0.5343.0 X64) will be used to manage the data with unique code written to sort data and perform descriptive analyses. A validated data management methodology will be utilized to clean and analyze the data. Data management procedures will include blinding, cleaning, and review of existing infusion data within the DoseTrac Infusion Management Software databases at each hospital. Patient-identifying data will be removed prior to merging into a dedicated and secure data repository. This pooled data will then be analyzed. This exploratory study will analyze the aggregate alarm data for each hospital by care area, drug infused, time of day, and day of week, including: overall infusion pump alarm frequency (number of alarms per active infusion), duration of alarms (average, range, median), and type and frequency of alarms distributed by care area. Infusion pump alarm data collected and analyzed in this study will be used to help establish a baseline of infusion pump alarm types and relative frequencies. Understanding the incidences and characteristics of infusion pump alarms will result in more informed quality improvement recommendations to decrease and/or modify infusion pump alarms, and potentially reduce clinical staff alarm fatigue and improve patient safety. . RR1-10.2196/10446. ©Kevin R Glover, Rachel R Vitoux, Catherine Schuster, Christopher R Curtin. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 14.06.2018.
Xie, Xiangyang; Yang, Yang; Yang, Yanfang; Li, Zhiping; Zhang, Hui; Chi, Qiang; Cai, Xingshi; Mei, Xingguo
2016-09-01
A novel, self-administration drug delivery system for subcutaneous infusion was developed and evaluated. The device includes two main components: an osmotic tablet controlled gas actuator and a syringe catheter system. The sodium carbonate in the osmotic pump tablet will release into the surround citric acid solution and produce CO 2 gas, which will drive the drug solution into subcutaneous tissue. The key formulation factors of the osmotic tablet that would influence the infusion profiles of the device were investigated by single factor exploration. The formulation was optimized via a response surface methodology. With an 18 ± 4 min of lag time, the delivery system was able to infuse at an approximate zero-order up to 5.90 ± 0.37 h with a precision of 9.0% RSD (n = 6). A linear correlation was found for the infusion profile and the fitting equation was Y = 0.014X - 0.004 (r = 0.998). A temperature change of 4 °C was found to modify the flow rate by about 12.0%. In vivo results demonstrated that the present subcutaneous infusion device was similar to the commercial infusion pump, and it could bring a long and constant ampicillin plasma level with minimized fluctuations.
[The development tendencies of infusion pumps/syringe pumps].
Zhang, Peng; Wang, Shu-Yi; Yu, Chuan-Yi; Zhang, Min-Yan
2009-07-01
Through the investigation about the current infusion pumps, the development tendencies of the next generation infusion pumps/Syringe Pumps with regarding to human-factors, practicality and application under MRI (Magnetic resonance imaging) were put forward.
21 CFR 870.1800 - Withdrawal-infusion pump.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Withdrawal-infusion pump. 870.1800 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1800 Withdrawal-infusion pump. (a) Identification. A withdrawal-infusion pump is a device designed to inject accurately drugs...
Schraagen, Jan Maarten; Verhoeven, Fenne
2013-02-01
The aims of this study were to investigate how a variety of research methods is commonly employed to study technology and practitioner cognition. User-interface issues with infusion pumps were selected as a case because of its relevance to patient safety. Starting from a Cognitive Systems Engineering perspective, we developed an Impact Flow Diagram showing the relationship of computer technology, cognition, practitioner behavior, and system failure in the area of medical infusion devices. We subsequently conducted a systematic literature review on user-interface issues with infusion pumps, categorized the studies in terms of methods employed, and noted the usability problems found with particular methods. Next, we assigned usability problems and related methods to the levels in the Impact Flow Diagram. Most study methods used to find user interface issues with infusion pumps focused on observable behavior rather than on how artifacts shape cognition and collaboration. A concerted and theory-driven application of these methods when testing infusion pumps is lacking in the literature. Detailed analysis of one case study provided an illustration of how to apply the Impact Flow Diagram, as well as how the scope of analysis may be broadened to include organizational and regulatory factors. Research methods to uncover use problems with technology may be used in many ways, with many different foci. We advocate the adoption of an Impact Flow Diagram perspective rather than merely focusing on usability issues in isolation. Truly advancing patient safety requires the systematic adoption of a systems perspective viewing people and technology as an ensemble, also in the design of medical device technology. Copyright © 2012 Elsevier Inc. All rights reserved.
75 FR 21641 - Infusion Pumps; Public Meeting; Request for Comments
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-26
...] Infusion Pumps; Public Meeting; Request for Comments AGENCY: Food and Drug Administration, HHS. ACTION... announcing a public meeting regarding external infusion pumps. The purpose of the meeting is to inform the public about current problems associated with external infusion pump use, to help the agency identify...
[Portable elastomeric infusion system applied to patients with knee prosthesis].
Soler, Gemma; Quiles, Olga; Nicolau, Agnes; Faura, Teresa; Moreno, Cristina
2007-03-01
An LV infuser consists of an infusion pump which can administer medicines via various methods: intravenous, epidural, subdural, o subcutaneous. Its usefulness is based on the administration of medicines such as oncological drugs and/or analgesic by means of a continuous infusion.
Specification and simulation of behavior of the Continuous Infusion Insulin Pump system.
Babamir, Seyed Morteza; Dehkordi, Mehdi Borhani
2014-01-01
Continuous Infusion Insulin Pump (CIIP) system is responsible for monitoring diabetic blood sugar. In this paper, we aim to specify and simulate the CIIP software behavior. To this end, we first: (1) presented a model consisting of the CIIP system behavior in response to its environment (diabetic) behavior and (2) we formally defined the safety requirements of the system environment (diabetic) in the Z formal modeling language. Such requirements should be satisfied by the CIIP software. Finally, we programmed the model and requirements.
[Morphine self-administration by rats using a pneumatic syringe].
Akiyama, Y; Takayama, S
1988-06-01
An apparatus for drug self-administration by rats using a pneumatic syringe was developed by Weeks. A microliter syringe operated by a pneumatic cylinder supplies an accurate volume of drug solution within one second. When coefficient of variation of infusion volume was compared among pneumatic syringe, infusion pump, and peristaltic pump, pneumatic syringe showed higher accuracy in infusion volume than the other two pumps. Since the infusion speed by a pneumatic syringe is very rapid (less than one second per infusion), the effect of infusion speed on reinforcing property of morphine was investigated. When rats self-administered 0.1, 0.3, 1.0, and 3.0 mg/kg/infusion of morphine by pneumatic syringes, the patterns of self-infusion were more stable, the number of self-infusions and the amount self-administered were larger, and a dose-response relationship was clearer in comparison with those self-infused the same doses of morphine for 5.6 seconds by infusion pumps or peristaltic pumps.
Home Healthcare Medical Devices: Infusion Therapy - Getting the Most Out of Your Pump
... and Consumer Devices Brochure - Home Healthcare Medical Devices: Infusion Therapy - Getting the Most Out of Your Pump ... therapy. What do you do before using your infusion pump? Read your pump's Instructions for Use and ...
Heuristic evaluation of infusion pumps: implications for patient safety in Intensive Care Units.
Graham, Mark J; Kubose, Tate K; Jordan, Desmond; Zhang, Jiajie; Johnson, Todd R; Patel, Vimla L
2004-11-01
The goal of this research was to use a heuristic evaluation methodology to uncover design and interface deficiencies of infusion pumps that are currently in use in Intensive Care Units (ICUs). Because these infusion systems cannot be readily replaced due to lease agreements and large-scale institutional purchasing procedures, we argue that it is essential to systematically identify the existing usability problems so that the possible causes of errors can be better understood, passed on to the end-users (e.g., critical care nurses), and used to make policy recommendations. Four raters conducted the heuristic evaluation of the three-channel infusion pump interface. Three raters had a cognitive science background as well as experience with the heuristic evaluation methodology. The fourth rater was a veteran critical care nurse who had extensive experience operating the pumps. The usability experts and the domain expert independently evaluated the user interface and physical design of the infusion pump and generated a list of heuristic violations based upon a set of 14 heuristics developed in previous research. The lists were compiled and then rated on the severity of the violation. From 14 usability heuristics considered in this evaluation of the Infusion Pump, there were 231 violations. Two heuristics, "Consistency" and "Language", were found to have the most violations. The one with fewest violations was "Document". While some heuristic evaluation categories had more violations than others, the most severe ones were not confined to one type. The Primary interface location (e.g., where loading the pump, changing doses, and confirming drug settings takes place) had the most occurrences of heuristic violations. We believe that the Heuristic Evaluation methodology provides a simple and cost-effective approach to discovering medical device deficiencies that affect a patient's general well being. While this methodology provides information for the infusion pump designs of the future, it also identifies important insights concerning equipment that is currently in use in critical care environments.
Control of cancer pain by epidural infusion of morphine.
Waterman, N G; Hughes, S; Foster, W S
1991-10-01
Pain that cannot be controlled by traditional oral and parenteral methods in those patients with advanced cancer can be alleviated by spinal administration of narcotics. Epidural and intrathecal infusion with morphine causes analgesia by blocking spinal receptors without significant long-term central nervous, gastrointestinal, and genitourinary system effects. Of the total of 33 patients, epidural catheters inserted in 20 patients then connected by a subcutaneous tunnel to a continuous infusion system. Implanted pumps were used in each of these patients. Because of the cost and limitations of the implanted pumps, epidural catheters were connected, either directly or by subcutaneous reservoirs, to external ambulatory infusion pumps in the remaining 13 patients. Patient assessment by a linear analogue scale to measure pain levels determined that 23 of the 33 total patients (70%) had excellent or good relief of pain. The delivery of spinal administration of narcotics to treat intractable cancer pain in patients is safe. Most importantly, this method of delivery can be used in community hospitals, in outpatient settings, and in home health care programs.
[Incorrect programming of a target controlled infusion pump. Case SENSAR of the trimester].
2014-10-01
We report the case of a patient who underwent surgical aortic valve replacement. During general anaesthesia maintenance, the patient received a remifentanyl infusion via a target controlled infusion (TCI) system. The infusion pump that was prepared to deliver the infusion showed malfunction at the beginning of the surgery, so it was quickly replaced with a second pump. After a few minutes into the surgery, the patient presented with hypotension refractory to treatment. The remifentanyl syringe also emptied faster than expected. On reviewing the TCI pump, it was found that it was erroneously programmed for propofol instead of remifentanyl, thus the patient had received a very high dose of remifentanyl that was probably the cause of the haemodynamic disturbances. The incident was an error in equipment use, facilitated by hurry, lack of checking of the equipment prior to its use, and the complex and unclear design of the devices' screens. After analysis of this incident, all TCI pumps were reviewed, and all the programs for infrequently used drugs were deleted. Furthermore, 2 pumps were selected for exclusive use in the cardiac surgery theatre, one with propofol-only programming, and the other with remifentanyl-only programming, both clearly marked and situated in fixed places in that theatre. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.
A Review of the Security of Insulin Pump Infusion Systems
Paul, Nathanael; Kohno, Tadayoshi; Klonoff, David C
2011-01-01
Insulin therapy has enabled patients with diabetes to maintain blood glucose control to lead healthier lives. Today, rather than injecting insulin manually using syringes, a patient can use a device such as an insulin pump to deliver insulin programmatically. This allows for more granular insulin delivery while attaining blood glucose control. Insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result, security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this article, we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components, which include the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues. PMID:22226278
A review of the security of insulin pump infusion systems.
Paul, Nathanael; Kohno, Tadayoshi; Klonoff, David C
2011-11-01
Insulin therapy has enabled patients with diabetes to maintain blood glucose control to lead healthier lives. Today, rather than injecting insulin manually using syringes, a patient can use a device such as an insulin pump to deliver insulin programmatically. This allows for more granular insulin delivery while attaining blood glucose control. Insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result, security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this article, we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components, which include the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues. © 2011 Diabetes Technology Society.
In vivo study of flow-rate accuracy of the MedStream Programmable Infusion System.
Venugopalan, Ramakrishna; Ginggen, Alec; Bork, Toralf; Anderson, William; Buffen, Elaine
2011-01-01
Flow-rate accuracy and precision are important parameters to optimizing the efficacy of programmable intrathecal (IT) infusion pump delivery systems. Current programmable IT pumps are accurate within ±14.5% of their programmed infusion rate when assessed under ideal environmental conditions and specific flow-rate settings in vitro. We assessed the flow-rate accuracy of a novel programmable pump system across its entire flow-rate range under typical conditions in sheep (in vivo) and nominal conditions in vitro. The flow-rate accuracy of the MedStream Programmable Pump was assessed in both the in vivo and in vitro settings. In vivo flow-rate accuracy was assessed in 16 sheep at various flow-rates (producing 90 flow intervals) more than 90 ± 3 days. Pumps were then explanted, re-sterilized and in vitro flow-rate accuracy was assessed at 37°C and 1013 mBar (80 flow intervals). In vivo (sheep body temperatures 38.1°C-39.8°C), mean ± SD flow-rate error was 9.32% ± 9.27% and mean ± SD leak-rate was 0.028 ± 0.08 mL/day. Following explantation, mean in vitro flow-rate error and leak-rate were -1.05% ± 2.55% and 0.003 ± 0.004 mL/day (37°C, 1013 mBar), respectively. The MedStream Programmable Pump demonstrated high flow-rate accuracy when tested in vivo and in vitro at normal body temperature and environmental pressure as well as when tested in vivo at variable sheep body temperature. The flow-rate accuracy of the MedStream Programmable Pump across its flow-rate range, compares favorably to the accuracy of current clinically utilized programmable IT infusion pumps reported at specific flow-rate settings and conditions. © 2011 International Neuromodulation Society.
Mandel, Jeff E
2018-04-01
Infusion systems are complicated electromechanical systems that are used to deliver anesthetic drugs with moderate precision. Four types of systems are described-gravity feed, in-line piston, peristaltic, and syringe. These systems are subject to a number of failure modes-occlusion, disconnection, siphoning, infiltration, and air bubbles. The relative advantages of the various systems and some of the monitoring capabilities are discussed. A brief example of the use of an infusion system during anesthetic induction is presented. With understanding of the functioning of these systems, users may develop greater comfort.
Primary Intravenous Set Consumption Across 3 Branded Infusion Pumps
Hedlund, Nancy; Sarangpur, Shishir; Kayler, Shannon; O'Brien, Kathy
2017-01-01
This retrospective study of 6426 hip replacement, coronary artery bypass graft, and colectomy surgeries across 23 US hospitals found that intravenous (IV) set designs that can be interchanged for use both in gravity-fed and automated pump delivery systems are replaced less frequently than IV sets designed for use primarily by one delivery method. Semistructured interviews with nurses highlighted the impact of set design on nursing workflow when moving between gravity-fed and pump-based administration. Use of interchangeable, single-design IV sets across gravity and automated infusions minimizes disruptions to closed systems, may reduce nurses being distracted from patients' clinical needs when replacing sets, and may yield supply cost savings. PMID:28682999
78 FR 1574 - Regulatory Agenda
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-08
... Infusion Pumps. 281 Requirements for the 0910-AG59 Testing and Reporting of Tobacco Product Constituents... Use Devices: Issuance of Draft Special Controls Guidance for Infusion Pumps Legal Authority: 21 U.S.C... proposing to amend the classification of infusion pumps from class II (performance standards) to class II...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-18
... Industry and FDA Staff; Total Product Life Cycle: Infusion Pump--Premarket Notification [510(k... for Industry and FDA Staff; Total Product Life Cycle: Infusion Pump--Premarket Notification [510(k... Staff; Total Product Life Cycle: Infusion Pump--Premarket Notification [510(k)] Submissions--0910-NEW...
Syroid, Noah; Liu, David; Albert, Robert; Agutter, James; Egan, Talmage D; Pace, Nathan L; Johnson, Ken B; Dowdle, Michael R; Pulsipher, Daniel; Westenskow, Dwayne R
2012-11-01
Drug administration errors are frequent and are often associated with the misuse of IV infusion pumps. One source of these errors may be the infusion pump's user interface. We used failure modes-and-effects analyses to identify programming errors and to guide the design of a new syringe pump user interface. We designed the new user interface to clearly show the pump's operating state simultaneously in more than 1 monitoring location. We evaluated anesthesia residents in laboratory and simulated environments on programming accuracy and error detection between the new user interface and the user interface of a commercially available infusion pump. With the new user interface, we observed the number of programming errors reduced by 81%, the number of keystrokes per task reduced from 9.2 ± 5.0 to 7.5 ± 5.5 (mean ± SD), the time required per task reduced from 18.1 ± 14.1 seconds to 10.9 ± 9.5 seconds and significantly less perceived workload. Residents detected 38 of 70 (54%) of the events with the new user interface and 37 of 70 (53%) with the existing user interface, despite no experience with the new user interface and extensive experience with the existing interface. The number of programming errors and workload were reduced partly because it took less time and fewer keystrokes to program the pump when using the new user interface. Despite minimal training, residents quickly identified preexisting infusion pump problems with the new user interface. Intuitive and easy-to-program infusion pump interfaces may reduce drug administration errors and infusion pump-related adverse events.
A continuous [15O]H2O production and infusion system for PET imaging
NASA Astrophysics Data System (ADS)
Sajjad, Munawwar; Liow, Jeih-San
1999-06-01
A system for continuous production and infusion of [15O]H2O has been designed for PET cerebral blood flow studies. The injection system consists of a four-port-two-position valve, two Horizon Nxt infusion pumps, and a sterile 50 ml vial. The variation of the production of [15O]H2O was <1%. The variation of activity delivered measured by scanner counts during the steady state period was <2%.
Nonmetabolic Complications of Continuous Subcutaneous Insulin Infusion: A Patient Survey
Yemane, Nardos; Brackenridge, Anna; Pender, Siobhan
2014-01-01
Abstract Background: Little is known about the frequencies and types of nonmetabolic complications occurring in type 1 diabetes patients being treated by modern insulin pump therapy (continuous subcutaneous insulin infusion [CSII]), when recorded by standardized questionnaire rather than clinical experience. Subjects and Methods: A self-report questionnaire was completed by successive subjects with type 1 diabetes attending an insulin pump clinic, and those with a duration of CSII of ≥6 months were selected for analysis (n=92). Questions included pump manufacturer, insulin, infusion set type and duration of use, frequency of infusion set and site problems, pump malfunctions, and patient-related problems such as weight change since starting CSII. Results: Median (range) duration of CSII was 3.3 (0.5–32.0) years, and mean±SD duration of infusion set use was 3.2±0.7 (range 2–6) days. The commonest infusion set problems were kinking (64.1% of subjects) and blockage (54.3%). Blockage was associated with >3 days of use of infusion sets plus lispro insulin in the pump (relative risk [95% confidence interval], 1.71 [1.03–2.85]; P=0.07). The commonest infusion site problem was lipohypertrophy (26.1%), which occurred more often in those with long duration of CSII (4.8 [2.38–9.45] vs. 3.0 [1.50–4.25] years; P=0.01). Pump malfunction had occurred in 48% of subjects (43% in the first year of CSII), with “no delivery,” keypad, and battery problems commonly occurring. Although some patients reported weight gain (34%) and some weight loss (15%) on CSII, most patients (51%) reported no change in weight. Conclusions: Pump, infusion set, and infusion site problems remain common with CSII, even with contemporary technology. PMID:24180294
Warming of infusion syringes caused by electronic syringe pumps.
Cornelius, A; Frey, B; Neff, T A; Gerber, A C; Weiss, M
2003-05-01
To evaluate inadvertent warming of the infusion syringe in four different types of electronic syringe pumps. Ambient temperature and syringe surface temperature were simultaneously measured by two electronic temperature probes in four different models of commercially available syringe pumps. Experiments were performed at an infusion rate of 1 ml h(-1) using both battery-operated and main power-operated pumps. Measurements were repeated four times with two pumps from each of the four syringe pump types at a room temperature of approximately 23 degrees C. Differences among the four syringe pump brands regarding ambient to syringe temperature gradient were compared using ANOVA. A P-value of less than 0.05 was considered statistically significant. Syringe warming differed significantly between the four syringe brands for both the battery-operated and main power-operated mode (ANOVA, P< 0.001 for both modes). Individual differences between syringe surface and ambient temperature ranged from 0.3 to 1.9 degrees C for battery operation and from 0.5 to 11.2 degrees C during main-power operation. Infusion solutions can be significantly warmed by syringe pumps. This has potential impact on bacterial growth and the stability of drug solutions and blood products infused, as well as on the susceptibility to hydrostatic pressure changes within the infusion syringe.
Klem, S A; Farrington, J M; Leff, R D
1993-08-01
To determine whether variations in the flow rate of epinephrine solutions administered via commonly available infusion pumps lead to significant variations in blood pressure (BP) in vivo. Prospective, randomized, crossover study with factorial design, using infusion pumps with four different operating mechanisms (pulsatile diaphragm, linear piston/syringe, cyclic piston-valve, and linear peristaltic) and three drug delivery rates (1, 5, and 10 mL/hr). Two healthy, mixed-breed dogs (12 to 16 kg). Dogs were made hypotensive with methohexital bolus and continuous infusion. BP was restored to normal with constant-dose epinephrine infusion via two pumps at each rate. Femoral mean arterial pressure (MAP) was recorded every 10 secs. Pump-flow continuity was quantitated in vitro using a digital gravimetric technique. Variations in MAP and flow continuity were expressed by the coefficient of variation; analysis of variance was used for comparisons. The mean coefficients of variations for MAP varied from 3.8 +/- 3.1% (linear piston/syringe) to 6.1 +/- 6.6% (linear peristaltic), and from 3.4 +/- 2.2% (10 mL/hr) to 7.9 +/- 6.6% (1 mL/hr). The coefficients of variation for in vitro flow continuity ranged from 9 +/- 8% (linear piston-syringe) to 250 +/- 162% (pulsatile diaphragm), and from 35 +/- 44% (10 mL/hr) to 138 +/- 196% (1 mL/hr). Both the type of pump and infusion rate significantly (p < .001) influenced variation in drug delivery rate. The 1 mL/hr infusion rate significantly (p < .01) influenced MAP variation. Cyclic fluctuations in MAP of < or = 30 mm Hg were observed using the pulsatile diaphragm pump at 1 mL/hr. Factors inherent in the operating mechanisms of infusion pumps may result in clinically important hemodynamic fluctuations when administering a concentrated short-acting vasoactive medication at slow infusion rates.
Smith, Melissa M; Hovsepian, Raffi V; Markarian, Mark K; Degelia, Amber L; Paul, Malcolm D; Evans, Gregory R D; Wirth, Garrett A
2008-11-01
Seroma formation is the most commonly occurring complication in plastic surgery abdominal procedures. Continuous local anesthetic pain pump delivery systems are often used to decrease postoperative pain. An unreported concern with use of these devices in abdominal procedures is the effect of continuous fluid infiltration of the surgical site and a possible increase in the incidence of seroma formation. The authors performed a retrospective chart review to evaluate all patients (n = 159) who underwent abdominal procedures (abdominoplasty, panniculectomy, and transverse rectus abdominis myocutaneous flap harvest) over a 3-year period. Patient charts were evaluated for sex, age, body mass index, procedure performed, surgeon, operation length, pain pump use, postoperative seroma formation, and any complications. In cases with pain pump use, catheter placement location, anesthetic medication and strength, continuous-infusion rate, and duration of pain pump use were also reviewed. If a postoperative seroma formation was identified, treatment and outcomes were also recorded. The overall seroma formation rate was 11.3 percent (18 of 159 patients). Other complications occurred at a rate of 2.5 percent (four of 159). The incidence of seroma was 11.0 percent (11 of 100) in patients with pain pump use versus 11.9 percent (7 of 59) in those who did not use a pain pump. There was no statistically significant difference (p = 0.9) in the incidence of seroma formation between those who did and did not use a pain pump device. There was no correlation between increased rate of seroma formation and use of a continuous-infusion local anesthetic pain pump system in our patient population.
Umemura, Masayuki; Maegawa, Kanae; Arai, Daichi; Shigeno, Katsuro; Wakiya, Yoshifumi
2018-01-01
Infusion sets designed for peristaltic finger smart pumps (PFSPs) are necessary for the pumps' accurate handling. We previously found that medication dispensing is occasionally incomplete following the calculated infusion time when using certain combinations of PFSPs and infusion sets at a Japanese hospital. Thus, in this study, we investigated the cause of this observed delay by determining the effect of infusion set attachment technique on dispensing time using a combination of three kinds of PFSPs and five kinds of polyvinyl chloride (PVC) and polybutadiene (PB) infusion sets. PFSPs with their exclusive infusion sets were used. The PVC and PB infusion sets were either not stretched or stretched to 1-3 cm and attached to the PFSP's liquid delivery system. PFSP dispensing rates were set at 25-400 mL/h. The primary outcome was the time required to dispense 100 mL of saline in a volumetric flask. The complete dispensing time correlated with the input time for all equipment combinations when the infusion sets were not stretched before attachment to the PFSP (R 2 = 0.9998-1.0000). When stretched, the complete dispensing time was longer than the input time ( P < 0.01-0.05, analysis of variance with Tukey-Kramer multiple comparisons). The maximum dispensing time extension ratio for the PVC and PB infusion sets was 141.8% and 113.0%, respectively. Certain attachment techniques for infusion sets can adversely prolong drug dispensing time. As such, pharmacists should provide medical staff with information about the devices used to administer drugs, as well as about the drugs themselves.
Insulin compatibility with polymer materials used in external pump infusion systems.
Melberg, S G; Havelund, S; Villumsen, J; Brange, J
1988-04-01
In a study designed to mimic actual user conditions for external insulin pump infusion, the insulin quality after passage through the infusion set was assessed by various analytical methods, including high performance liquid chromatography. The two infusion sets tested consisted of, firstly, a polyvinylchloride/rubber syringe and a polyvinylchloride catheter sterilized by gamma irradiation and, secondly, a polyethylene/polypropylene syringe connected to a polyethylene catheter and sterilized by ethylene oxide. The insulin solution delivered through the PVC infusion set showed a reduction of preservative to less than 30% of the initial content and increased formation of chemical transformation products of insulin varying from twice the reference level during the first day to more than three times on the third day. By contrast, the polyethylene/polypropylene infusion system showed only a minor decrease in preservative content and no increase in chemical transformation. These effects were observed irrespective of the brand of insulin and were not affected by increase of the zinc content of the insulin solution. Investigation of the influence of the sterilization methods performed on polyvinylchloride and polyethylene catheters revealed that gamma irradiated polyvinylchloride catheters were markedly harmful to the insulin solution, whereas ethylene oxide sterilization did not influence the chemical stability of insulin.
77 FR 7946 - Regulatory Agenda
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-13
... for Infusion Pumps. 344 Requirements for the 0910-AG59 Testing and Reporting of Tobacco Product... Infusion Pumps Legal Authority: 21 U.S.C. 351; 21 U.S.C. 360; 21 U.S.C. 360c; 21 U.S.C. 360e; 21 U.S.C... infusion pumps. An analysis of the reports reveals that a majority of the recalls and failures were caused...
Ryan, Melissa K; Ritchie, Brett; Sluggett, Janet K; Sluggett, Andrew J; Ralton, Lucy; Reynolds, Karen J
2017-01-01
Introduction Previous studies comparing satisfaction with electronic and elastomeric infusion pumps are limited, and improvements in size and usability of electronic pumps have since occurred. The Comparing Home Infusion Devices (CHID) study plans to assess patient and nurse satisfaction with an elastomeric and electronic pump for delivering intravenous antibiotic treatment in the home. Secondary objectives are to determine pump-related complications and actual antibiotic dose administered, evaluate temperature variation and compare pump operating costs. Methods and analysis The CHID study will be a randomised, crossover trial. A trained research nurse will recruit patients with infectious disease aged ≥18 years and prescribed ≥8 days of continuous intravenous antibiotic therapy from the Royal Adelaide Hospital (RAH) (Adelaide, Australia). Patients will be randomised to receive treatment at home via an elastomeric (Baxter Infusor) or an electronic (ambIT Continuous) infusion pump for 4–7 days, followed by the other for a further 4–7 days. Patient satisfaction will be assessed by a 10-item survey to be completed at the end of each arm. Nurse satisfaction will be assessed by a single 24-item survey. Patient logbooks and case notes from clinic visits will be screened to identify complications. Pumps/infusion bags will be weighed to estimate the volume of solution delivered. Temperature sensors will record skin and ambient temperatures during storage and use of the pumps throughout the infusion period. Costs relating to pumps, consumables, antibiotics and servicing will be determined. Descriptive statistics will summarise study data. Ethics and dissemination This study has been approved by the RAH Human Research Ethics Committee (HREC/16/RAH/133 R20160420, version 6.0, 5 September 2016). Study results will be disseminated through peer-reviewed publications and conference presentations. The CHID study will provide key insights into patient and provider satisfaction with elastomeric and electronic infusion pumps and inform future device selection. Trial registration number ACTRN12617000251325; Pre-results. PMID:28760798
Hobbs, Jodie G; Ryan, Melissa K; Ritchie, Brett; Sluggett, Janet K; Sluggett, Andrew J; Ralton, Lucy; Reynolds, Karen J
2017-07-31
Previous studies comparing satisfaction with electronic and elastomeric infusion pumps are limited, and improvements in size and usability of electronic pumps have since occurred. The Comparing Home Infusion Devices (CHID) study plans to assess patient and nurse satisfaction with an elastomeric and electronic pump for delivering intravenous antibiotic treatment in the home. Secondary objectives are to determine pump-related complications and actual antibiotic dose administered, evaluate temperature variation and compare pump operating costs. The CHID study will be a randomised, crossover trial. A trained research nurse will recruit patients with infectious disease aged ≥18 years and prescribed ≥8 days of continuous intravenous antibiotic therapy from the Royal Adelaide Hospital (RAH) (Adelaide, Australia). Patients will be randomised to receive treatment at home via an elastomeric (Baxter Infusor) or an electronic (ambIT Continuous) infusion pump for 4-7 days, followed by the other for a further 4-7 days. Patient satisfaction will be assessed by a 10-item survey to be completed at the end of each arm. Nurse satisfaction will be assessed by a single 24-item survey. Patient logbooks and case notes from clinic visits will be screened to identify complications. Pumps/infusion bags will be weighed to estimate the volume of solution delivered. Temperature sensors will record skin and ambient temperatures during storage and use of the pumps throughout the infusion period. Costs relating to pumps, consumables, antibiotics and servicing will be determined. Descriptive statistics will summarise study data. This study has been approved by the RAH Human Research Ethics Committee (HREC/16/RAH/133 R20160420, version 6.0, 5 September 2016). Study results will be disseminated through peer-reviewed publications and conference presentations. The CHID study will provide key insights into patient and provider satisfaction with elastomeric and electronic infusion pumps and inform future device selection. ACTRN12617000251325; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Jensen, Vivi Flou Hjorth; Mølck, Anne-Marie; Mårtensson, Martin; Strid, Mette Aagaard; Chapman, Melissa; Lykkesfeldt, Jens; Bøgh, Ingrid Brück
2017-06-01
Group housing is considered to be important for rats, which are highly sociable animals. Single housing may impact behaviour and levels of circulating stress hormones. Rats are typically used in the toxicological evaluation of insulin analogues. Human insulin (HI) is frequently used as a reference compound in these studies, and a comparator model of persistent exposure by HI infusion from external pumps has recently been developed to support toxicological evaluation of long-acting insulin analogues. However, this model requires single housing of the animals. Developing an insulin-infusion model which allows group housing would therefore greatly improve animal welfare. The aim of the present study was to investigate the suitability of implantable infusion pumps for HI infusion in group-housed rats. Group housing of rats implanted with a battery-driven pump proved to be possible. Intravenous infusion of HI lowered blood glucose levels persistently for two weeks, providing a comparator model for use in two-week repeated-dose toxicity studies with new long-acting insulin analogues, which allows group housing, and thereby increasing animal welfare compared with an external infusion model.
Wilson, Ana Maria Miranda Martins; Peterlini, Maria Angélica Sorgini; Pedreira, Mavilde da Luz Gonçalves
2016-01-01
ABSTRACT Objectives: to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells) and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. Method: an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. Results: all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. Conclusion: infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies. PMID:27533272
In-line pressure within a HOTLINE® Fluid Warmer, under various flow conditions.
Higashi, Midoriko; Yamaura, Ken; Matsubara, Yukie; Fukudome, Takuya; Hoka, Sumio
2015-04-01
Roller pump infusion devices are widely used for rapid infusion, and may be combined with separate warming devices. There may be instances however, where the pressures generated by the roller pump may not be compatible with the warming device. We assessed a commonly used roller pump in combination with a HOTLINE® Fluid Warmer, and found that it could generate pressures exceeding the HOTLINE® manufacturers specifications. This was of concern because the HOTLINE® manufacturer guideline states that not for use with pressure devices generating over 300 mmHg. Pressure greater than 300 mmHg may compromise the integrity of the HOTLINE® Fluid Warming Set. The aim of this study was to compare in-line pressure within a HOTLINE® Fluid Warmer at different infusion rates of a roller pump using various sizes of intravenous cannulae. The rapid infusion system comprised a 500 mL-normal saline bag, roller pump type infusion device, HOTLINE® Fluid Warmer (blood and fluid warmer system), and six different sizes of intravenous cannulae. In-line pressure was measured proximal to the HOTLINE® (pre-warmer) and proximal to the cannula (post-warmer), at flow rate of 50-160 mL/min. The in-line pressures increased significantly with increasing flow rate. The pre-warmer pressures exceeded 300 mmHg when the flow rate was ≥120 mL/min with 20-gauge, 48 mm length cannula, 130 with 20-gauge, 25 mm cannula, and 160 mL/min with 18-gauge, 48 mm cannula. However, they were <300 mmHg at any flow rates with 18-gauge, 30 mm cannula and 16-gauge cannulae. The post-warmer pressures exceeded 300 mmHg at the flow rate of 140 mL/min with 20-gauge, 48 mm cannula, and 160 mL/min with 20-gauge, 25 mm cannula, while they were <300 mmHg at any flow rates with 18 and 16-gauge cannulae. The in-line pressure within a HOTLINE® could exceed 300 mmHg, depending on the flow rate and size and length of cannula. It is important to pay attention to the size and length of cannulae and flow rate to keep the maximum in-line pressure<300 mmHg when a roller pump type infusion device is used.
Heinemann, Lutz; Fleming, G Alexander; Petrie, John R; Holl, Reinhard W; Bergenstal, Richard M; Peters, Anne L
2015-05-01
Insulin pump therapy, also known as continuous subcutaneous insulin infusion (CSII), is an important and evolving form of insulin delivery, which is mainly used for people with type 1 diabetes. However, even with modern insulin pumps, errors of insulin infusion can occur due to pump failure, insulin infusion set (IIS) blockage, infusion site problems, insulin stability issues, user error or a combination of these. Users are therefore exposed to significant and potentially fatal hazards: interruption of insulin infusion can result in hyperglycaemia and ketoacidosis; conversely, delivery of excessive insulin can cause severe hypoglycaemia. Nevertheless, the available evidence on the safety and efficacy of CSII remains limited. The European Association for the Study of Diabetes (EASD) and American Diabetes Association (ADA) have therefore joined forces to review the systems in place for evaluating the safety of pumps from a clinical perspective. We found that useful information held by the manufacturing companies is not currently shared in a sufficiently transparent manner. Public availability of adverse event (AE) reports on the US Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database is potentially a rich source of safety information but is insufficiently utilised due to the current configuration of the system; the comparable database in Europe (European Databank on Medical Devices, EUDAMED) is not publicly accessible. Many AEs appear to be attributable to human factors and/or user error, but the extent to which manufacturing companies are required by regulators to consider the interactions of users with the technical features of their products is limited. The clinical studies required by regulators prior to marketing are small and over-reliant on bench testing in relation to 'predicate' products. Once a pump is available on the market, insufficient data are made publicly available on its long-term use in a real-world setting; such data could provide vital information to help healthcare teams to educate and support users, and thereby prevent AEs. As well as requiring more from the manufacturing companies, we call for public funding of more research addressing clinically important questions in relation to pump therapy: both observational studies and clinical trials. At present there are significant differences in the regulatory systems between the USA and European Union at both pre- and post-marketing stages; improvements in the European system are more urgently required. This statement concludes with a series of recommended specific actions for 'meknovigilance' (i.e. a standardised safety approach to technology) which could be implemented to address the shortcomings we highlight.
Quantitative assessment of haemolysis secondary to modern infusion pumps.
Poder, T G; Boileau, J-C; Lafrenière, R; Thibault, L; Carrier, N; de Grandmont, M-J; Beauregard, P
2017-04-01
Although most studies have shown that little haemolysis is induced by infusion pumps, there are some notable exceptions. Only limited data are available on the actual infusion pumps that are most used in hospitals in Quebec and elsewhere, namely, the Infusomat ® Space (peristaltic), Plum A+™ (piston) and Colleague ® CXE (shuttle) pumps. Haemolysis and potassium levels were compared before and after the use of the three different infusion pumps. Using 135 units of packed red blood cells (RBCs) aged from 10 to 28 days, 27 measurements were taken for each pump at various flow rates (30, 60, 150, 300 and 450 ml/h) and were compared with measurements taken before using the pumps. The range of flow rates was chosen to cover those of paediatric and adult transfusions. The shuttle- and piston-type pumps resulted in low haemolysis levels. The peristaltic-type pump produced significantly more haemolysis, which worsened at low flow rates, but the absolute value of haemolysis remained within the range recommended by the regulatory agencies in North America and Europe. Approximately two-thirds of the haemolysis produced by the peristaltic-type pump seemed to be secondary to the use of an antisiphon valve (ASV) on the transfusion line recommended by the manufacturer. Potassium levels did not increase with the use of the pumps. Modern infusion pumps widely used in hospitals in Quebec and elsewhere produce non-threatening levels of haemolysis during the transfusion of packed RBCs aged from 10 to 28 days. ASVs appear to induce additional haemolysis, and we do not recommend using them for blood transfusion. © 2017 International Society of Blood Transfusion.
Menahem, Sasson; Shvartzman, Pesach
2010-09-01
The purpose of this study was to evaluate safety, feasibility, and efficacy of continuous drug delivery by the subcutaneous route through a solution bag connected to an infusion set compared with an infusion pump in a home palliative care setting. Patients in need of continuous subcutaneous medication delivery for pain control, nausea, and/or vomiting were recruited. The study was designed as a double-blind, crossover study. The patient was connected to two parallel subcutaneous lines running simultaneously, connected together to a line entering the subcutaneous tissue. One line is connected to an infusion set and the other to a pump. The infusion set included a 500-cc solution bag connected to a 1.5-m plastic tube containing a drip chamber controlled by a roller clamp that is gravity driven without hyaluronidase. Active medications were randomly assigned to start in either administration method and switched after 24 h. An independent research assistant evaluated symptom control and side effects at baseline and every 24 h for 2 days using a structured questionnaire. Another independent research assistant connected the lines after adding medications and evaluated technical and clinical failures. Twenty-seven patients were recruited, and of them, 18 completed the study. Incidents in fluid administration were more common through the infusion set (18 times) compared to the pump (only twice). On the other hand, no clinical significant change was noted in the average symptom levels and side effects when medications were given through the infusion set versus the pump. No local edema or irritation was observed in either way of administration. In a home palliative care setting with a medical staff on call for 24 h, using medications for symptom control can be considered to be infused to a fluid solution bag through an infusion set instead of using a syringe driver or a pump when there is a responsible caregiver to follow up on the fluid. Subcutaneous constant drug delivery through a pump is more accurate.
21 CFR 870.1800 - Withdrawal-infusion pump.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Withdrawal-infusion pump. 870.1800 Section 870.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1800 Withdrawal-infusion...
Protein delivery with infusion pumps.
Bremer, U; Horres, C R; Francoeur, M L
1997-01-01
When a therapeutic effect is optimized by precise control of specific temporal patterns of plasma levels, infusion offers distinct advantages over oral administration, bolus injection, or depot delivery of polypeptides. The limitations of oral delivery are well known, and although research is under way into development of carrier systems that prevent degradation of labile agents, it is unlikely that the variances in absorption will meet the need for precise control. Depot delivery from subcutaneous or intramuscular implants presents a difficult situation when local tissue reactions to the agent sometimes occur. Removal of a depot system in the event of adverse reactions presents additional difficulties. Bolus injections are unable to sustain constant plasma levels unless the drug half-life is long or the injections are frequently administered. Insulin injections, for example, would be required every 30-60 minutes to approximate the plasma levels provided by a continuous infusion; such frequent injections would not be practical on a 24-hour basis. For the developer of new polypeptides, parenteral administration offers the most direct route to the marketplace. The step from periodic injections to tightly controlled infusion is a logical progression as compared with modification of the molecules or vehicles to obtain equivalent profiles. In Table II several different types of devices that can be used for infusion of proteins are compared. Microelectronics have played a major role in the miniaturization of infusion devices and undoubtedly will continue to do so. Micromachining, a spin-off technology of integrated circuit manufacture, will also find application in small infusion devices. In the future, we will have cost-effective disposable devices (Saaman et al., 1994) built on this technology that are programmable and thus can be adapted to meet each individual therapeutic need (Horres, 1994). We can also expect to see more closed-loop drug delivery systems where biosensors and infusion devices are combined to optimize a particular therapy. Recent positive results obtained in diabetics by a decade on tight glucose control may forecast a resurgence of popularity of insulin pumps. At the other end of the spectrum, low-cost, small, and simple-to-use osmotically powered systems are close to being marketed; these systems will make infusion almost as convenient as transdermal patches. We will also see major advances in how drugs and devices are interfaced. Prefilled and ready-to-use drug cartridges have proven to be efficient in surgical and emergency medicine and can greatly improve most infusion applications. It is anticipated that coded, prefilled cartridges or pouches will be automatically, recognized by preprogrammed pumps to reduce operator labor and entry error.
Ruan, Xiulu; Couch, J Patrick; Liu, HaiNan; Shah, Rinoo V; Wang, Frank; Chiravuri, Srinivas
2010-01-01
Spinal analgesia, mediated by opioid receptors, requires only a fraction of the opioid dose that is needed systemically. By infusing a small amount of opioid into the cerebrospinal fluid in close proximity to the receptor sites in the spinal cord, profound analgesia may be achieved while sparing some of the side effects due to systemic opioids. Intraspinal drug delivery (IDD) has been increasingly used in patients with intractable chronic pain, when these patients have developed untoward side effects with systemic opioid usage. The introduction of intrathecal opioids has been considered one of the most important breakthroughs in pain management in the past three decades. A variety of side effects associated with the long-term usage of IDD have been recognized. Among them, respiratory depression is the most feared. To describe a severe adverse event, i.e., respiratory failure, following delayed intrathecal morphine pump refill. A 65-year-old woman with intractable chronic low back pain, due to degenerative disc disease, and was referred to our clinic for an intraspinal drug delivery evaluation, after failing to respond to multidisciplinary pain treatment. Following a psychological evaluation confirming her candidacy, she underwent an outpatient patient-controlled continuous epidural morphine infusion trial. The infusion trial lasted 12 days and was beneficial in controlling her pain. The patient reported more than 90% pain reduction with improved distance for ambulation. She subsequently consented and was scheduled for permanent intrathecal morphine pump implantation. The intrathecal catheter was inserted at right paramedian L3-L4, with catheter tip advanced to L1, confirmed under fluoroscopy. Intrathecal catheter placement was confirmed by positive CSF flow and by myelogram. A non-programmable Codman 3000 constant-flow rate infusion pump was placed in the right mid quandrant between right rib cage and right iliac crest. The intrathecal infusion consisted of preservative free morphine, delivering 1.0 mg /day. Over the following 6 months, the dosage was gradually titrated up to 4 mg/day with satisfactory pain control without significant side effects. However, the patient was not able to return to the clinic for pump refill until 12 days later than the previously scheduled pump-refill date. Her pump was accessed and was noted to be empty. Her intrathecal pump was refilled with preservative free morphine, delivering 4 mg/day (the same daily dose as her previous refill). However, on the night of pump refill, 10 hours after the pump refill, the patient was found to be unresponsive by her family members. 911 was called. Upon arriving, paramedics found her in respiratory failure, with shallow breathing at a rate of 5/min, pulse oxymetry showing oxygen saturation about 55-58%. She was emergently intubated on site and rushed to local hospital ER. The on call physician for our clinic was immediately contacted, and advised the administration of intravenous Naloxone. Her respiratory effort improved dramatically after receiving a total of 0.6 mg IV Naloxone IV over 25 minutes. Her intrathecal pump was immediately accessed by clinic on call physician and the remainder of the medication in the catheter space was aspirated. The pump infusate was immediately diluted with preservative free normal saline, to deliver preservative free morphine at 1mg/day. She was transferred to the intensive care unit and extubated the next morning. She recovered fully without any sequelae. Loss of opioid tolerance due to delayed pump refill may subject patients to the development of severe respiratory depression. Meticulous approach should be employed when refilling pumps in these patients when their pumps are completely empty. To our knowledge, this is the first reported case of this type.
Subcutaneous narcotic infusions for cancer pain: treatment outcome and guidelines for use.
Moulin, D E; Johnson, N G; Murray-Parsons, N; Geoghegan, M F; Goodwin, V A; Chester, M A
1992-03-15
To provide guidelines for the institution and maintenance of a continuous subcutaneous narcotic infusion program for cancer patients with chronic pain through an analysis of the narcotic requirements and treatment outcomes of patients who underwent such therapy and a comparison of the costs of two commonly used infusion systems. Retrospective study. Tertiary care facilities and patients' homes. Of 481 patients seen in consultation for cancer pain between July 1987 and April 1990, 60 (12%) met the eligibility criteria (i.e., standard medical management had failed, and they had adequate supervision at home). Continuous subcutaneous infusion with hydromorphone hydrochloride or morphine started on an inpatient basis and continued at home whenever possible. Patient selectivity, narcotic dosing requirements, discharge rate, patient preference for analgesic regimen, side effects, complications and cost-effectiveness. The mean initial maintenance infusion dose after dose titration was almost three times higher than the dose required before infusion (hydromorphone or equivalent 6.2 v. 2.1 mg/h). Eighteen patients died, and the remaining 42 were discharged home for a mean of 94.4 (standard deviation 128.3) days (extremes 12 and 741 days). The mean maximum infusion rate was 24.1 mg/h (extremes 0.5 and 180 mg/h). All but one of the patients preferred the infusion system to their previous oral analgesic regimen. Despite major dose escalations nausea and vomiting were well controlled in all cases. Twelve patients (20%) experienced serious systemic toxic effects or complications; six became encephalopathic, which necessitated dose reduction, five had a subcutaneous infection necessitating antibiotic treatment, and one had respiratory depression. The programmable computerized infusion pump was found to be more cost-effective than the disposable infusion device after a break-even point of 8 months. Continuous subcutaneous infusion of opioid drugs with the use of a portable programmable pump is safe and effective in selected patients who have failed to respond to standard medical treatment of their cancer pain. Dose titration may require rapid dose escalation, but this is usually well tolerated. For most communities embarking on such a program a programmable infusion system will be more cost-effective than a disposable system.
Houliston, Bryan; Parry, David; Webster, Craig S; Merry, Alan F
2009-06-19
To replicate electromagnetic interference (EMI) with a common drug infusion device resulting from the use of radio frequency identification (RFID) technology in a simulated operating theatre environment. An infusion pump, of a type previously reported as having failed due to RFID EMI, was placed in radio frequency (RF) fields of various strengths, and its operation observed. Different strength RF fields were created by varying the number of RFID readers, the use of a high-gain RFID antenna, the distance between the reader(s) and the infusion pump, and the presence of an RFID tag on the infusion pump. The infusion pump was not affected by low-power RFID readers, even when in direct contact. The pump was disrupted by a high-power reader at 10 cm distance when an RFID tag was attached, and by a combination of high-power and low-power readers at 10 cm distance. Electronic medical devices may fail in the presence of high-power RFID readers, especially if the device is tagged. However, low-power RFID readers appear to be safer.
Programmable Infusion Pumps in ICUs: An Analysis of Corresponding Adverse Drug Events
Bower, Anthony G.; Paddock, Susan M.; Hilborne, Lee H.; Wallace, Peggy; Rothschild, Jeffrey M.; Griffin, Anne; Fairbanks, Rollin J.; Carlson, Beverly; Panzer, Robert J.; Brook, Robert H.
2007-01-01
Background Patients in intensive care units (ICUs) frequently experience adverse drug events involving intravenous medications (IV-ADEs), which are often preventable. Objectives To determine how frequently preventable IV-ADEs in ICUs match the safety features of a programmable infusion pump with safety software (“smart pump”) and to suggest potential improvements in smart-pump design. Design Using retrospective medical-record review, we examined preventable IV-ADEs in ICUs before and after 2 hospitals replaced conventional pumps with smart pumps. The smart pumps alerted users when programmed to deliver duplicate infusions or continuous-infusion doses outside hospital-defined ranges. Participants 4,604 critically ill adults at 1 academic and 1 nonacademic hospital. Measurements Preventable IV-ADEs matching smart-pump features and errors involved in preventable IV-ADEs. Results Of 100 preventable IV-ADEs identified, 4 involved errors matching smart-pump features. Two occurred before and 2 after smart-pump implementation. Overall, 29% of preventable IV-ADEs involved overdoses; 37%, failures to monitor for potential problems; and 45%, failures to intervene when problems appeared. Error descriptions suggested that expanding smart pumps’ capabilities might enable them to prevent more IV-ADEs. Conclusion The smart pumps we evaluated are unlikely to reduce preventable IV-ADEs in ICUs because they address only 4% of them. Expanding smart-pump capabilities might prevent more IV-ADEs. PMID:18095043
Total intravenous anesthesia as a target-controlled infusion. An evolutive analysis.
Nora, Fernando Squeff
2008-01-01
Total intravenous anesthesia (TIVA) has seen several developments since it was first used. Since the synthesis of the first intravenous anesthetics, with the introduction of barbiturates (1921) and thiopental (1934), TIVA has evolved until the development of TIVA with target-controlled infusion pumps (TCI). The first pharmacokinetic model for the use of TCI was described by Schwilden in 1981. From that moment on, it was demonstrated that it is possible to maintain the desired plasma concentration of a drug using an infusion pump managed by a computer. The objective of this report was to describe the theoretical bases of TCI, propose the development of a common TCI vocabulary, which has not been done in Brazil and make a critical analysis of the current aspects of TCI in the world and in Brazil. The advent of new infusion pumps with pharmacokinetic models of remifentanil, sufentanil and propofol opens a new chapter in TIVA and aligns Brazil with the world tendency in TCI. Those systems will allow TCI of hypnotics and opioids concomitantly. However, the most important conclusion refers to the economy, since drugs used in those pumps will not be restricted to only one drug company, similar to what happened with propofol. Nowadays, TCI devices for the use of propofol and opioids, which accept any pharmaceutical presentation, with the advantage of changing the concentration of the drug in the syringe according to the dilution desired are available.
Iliev, Peter; Bhalla, Tarun; Tobias, Joseph D
2016-04-01
The Ambu Smart-Infuser Pain Pump and the On-Q Pump with Select-a-Flow Variable Rate Controller are elastomeric devices with a flow regulator that controls the rate of infusion of a local anesthetic agent through a peripheral catheter. As a safety evaluation, we evaluated the infusion characteristics of these two devices when filled with manufacturer recommended standard volumes and when overfilled with a volume 50% in excess of that which is recommended. Nineteen disposable devices from the two manufacturers were used in this study. Nine were filled with 0.9% normal saline according to the respective manufacturers' recommendations (four Ambu pumps were filled with 650 ml and five On-Q pumps were filled with 550 ml) and 10 devices were 150% overfilled (five Ambu pumps were filled with 975 ml and five On-Q pumps were filled with 825 ml). All of the devices were set to infuse at 10 ml · h(-1) at room temperature (21°C) for 12 h. The fluid delivered during each 2-h period was measured using a graduated column. The On-Q pump (in the settings of normal fill and 150% overfill) delivered a significantly higher output per hour than the set rate during the first 8 h, while the Ambu pump delivered a value close to the set rate of 10 ml · h(-1). No significant difference in the hourly delivered output was noted for either device when comparing the normal fill to the 150% overfill groups. This investigation demonstrates that no change in the hourly output occurs with overfilling of these home infusion devices. However, as noted previously, the hourly output from the On-Q device is significantly higher than the set rate during the initial 8 h of infusion which could have potential clinical implications. © 2016 John Wiley & Sons Ltd.
Implementing smart infusion pumps with dose-error reduction software: real-world experiences.
Heron, Claire
2017-04-27
Intravenous (IV) drug administration, especially with 'smart pumps', is complex and susceptible to errors. Although errors can occur at any stage of the IV medication process, most errors occur during reconstitution and administration. Dose-error reduction software (DERS) loaded on to infusion pumps incorporates a drug library with predefined upper and lower drug dose limits and infusion rates, which can reduce IV infusion errors. Although this is an important advance for patient safety at the point of care, uptake is still relatively low. This article discuses the challenges and benefits of implementing DERS in clinical practice as experienced by three UK trusts.
Heinemann, Lutz; Fleming, G Alexander; Petrie, John R; Holl, Reinhard W; Bergenstal, Richard M; Peters, Anne L
2015-04-01
Insulin pump therapy, also known as continuous subcutaneous insulin infusion (CSII), is an important and evolving form of insulin delivery, which is mainly used for people with type 1 diabetes. However, even with modern insulin pumps, errors of insulin infusion can occur due to pump failure, insulin infusion set (IIS) blockage, infusion site problems, insulin stability issues, user error, or a combination of these. Users are therefore exposed to significant and potentially fatal hazards: interruption of insulin infusion can result in hyperglycemia and ketoacidosis; conversely, delivery of excessive insulin can cause severe hypoglycemia. Nevertheless, the available evidence on the safety and efficacy of CSII remains limited. The European Association for the Study of Diabetes (EASD) and the American Diabetes Association (ADA) have therefore joined forces to review the systems in place for evaluating the safety of pumps from a clinical perspective. We found that useful information held by the manufacturing companies is not currently shared in a sufficiently transparent manner. Public availability of adverse event (AE) reports on the US Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database is potentially a rich source of safety information but is insufficiently utilized due to the current configuration of the system; the comparable database in Europe (European Databank on Medical Devices [EUDAMED]) is not publicly accessible. Many AEs appear to be attributable to human factors and/or user error, but the extent to which manufacturing companies are required by regulators to consider the interactions of users with the technical features of their products is limited. The clinical studies required by regulators prior to marketing are small and over-reliant on bench testing in relation to "predicate" products. Once a pump is available on the market, insufficient data are made publicly available on its long-term use in a real-world setting; such data could provide vital information to help health care teams to educate and support users and thereby prevent AEs. As well as requiring more from the manufacturing companies, we call for public funding of more research addressing clinically important questions in relation to pump therapy: both observational studies and clinical trials. At present, there are significant differences in the regulatory systems between the US and European Union at both pre- and postmarketing stages; improvements in the European system are more urgently required. This statement concludes with a series of recommended specific actions for "meknovigilance" (i.e., a standardized safety approach to technology) that could be implemented to address the shortcomings we highlight. © 2015 by the American Diabetes Association and Springer-Verlag. Copying with attribution allowed for any noncommercial use of the work.
Zhang, Yeying; Lu, Ming; Chang, Cheng
2017-01-23
We performed a systematic review and meta-analysis of randomized controlled trials (RCTs) were to evaluate the effect and safety of local anesthetic infusion pump versus placebo for pain management following total knee arthroplasty (TKA). In September 2016, a systematic computer-based search was conducted in the Pubmed, ISI Web of Knowledge, Embase, Cochrane Database of Systematic Reviews. Randomized controlled trials of patients prepared for primary TKA that compared local anesthetic infusion pump versus placebo for pain management following TKA were retrieved. The primary endpoint was the visual analogue scale (VAS) with rest or mobilization at 24, 48 and 72 h and morphine consumption at 24 and 48 h. The second outcomes are range of motion, length of hospital stay (LOS) and complications (infection, deep venous thrombosis (DVT), prolonged drainage and postoperative nausea and vomiting (PONV)). Seven clinical studies with 587 patients were included and for meta-analysis. Local anesthetic infusion pump are associated with less pain scores with rest or mobilization at 24 and 48 h with significant difference. However, the difference was likely no clinical significance. There were no significant difference between the LOS, the occurrence of DVT, prolonged drainage and PONV. However, local anesthetic infusion pump may be associated with more infection. Based on the current meta-analysis, we found no evidence to support the routine use of local anesthetic infusion pump in the management of acute pain following TKA. More RCTs are still need to identify the pain control effects and optimal dose and speed of local anesthetic pain pump.
Programmable control means for providing safe and controlled medication infusion
NASA Technical Reports Server (NTRS)
Fischell, Robert E. (Inventor)
1988-01-01
An implantable programmable infusion pump (IPIP) is disclosed and generally includes: a fluid reservoir filled with selected medication; a pump for causing a precise volumetric dosage of medication to be withdrawn from the reservoir and delivered to the appropriate site within the body; and, a control means for actuating the pump in a safe and programmable manner. The control means includes a microprocessor, a permanent memory containing a series of fixed software instructions, and a memory for storing prescription schedules, dosage limits and other data. The microprocessor actuates the pump in accordance with programmable prescription parameters and dosage limits stored in the memory. A communication link allows the control means to be remotely programmed. The control means incorporates a running integral dosage limit and other safety features which prevent an inadvertent or intentional medication overdose. The control means also monitors the pump and fluid handling system and provides an alert if any improper or potentially unsafe operation is detected.
Comparison of infusion pumps calibration methods
NASA Astrophysics Data System (ADS)
Batista, Elsa; Godinho, Isabel; do Céu Ferreira, Maria; Furtado, Andreia; Lucas, Peter; Silva, Claudia
2017-12-01
Nowadays, several types of infusion pump are commonly used for drug delivery, such as syringe pumps and peristaltic pumps. These instruments present different measuring features and capacities according to their use and therapeutic application. In order to ensure the metrological traceability of these flow and volume measuring equipment, it is necessary to use suitable calibration methods and standards. Two different calibration methods can be used to determine the flow error of infusion pumps. One is the gravimetric method, considered as a primary method, commonly used by National Metrology Institutes. The other calibration method, a secondary method, relies on an infusion device analyser (IDA) and is typically used by hospital maintenance offices. The suitability of the IDA calibration method was assessed by testing several infusion instruments at different flow rates using the gravimetric method. In addition, a measurement comparison between Portuguese Accredited Laboratories and hospital maintenance offices was performed under the coordination of the Portuguese Institute for Quality, the National Metrology Institute. The obtained results were directly related to the used calibration method and are presented in this paper. This work has been developed in the framework of the EURAMET projects EMRP MeDD and EMPIR 15SIP03.
McVey, Elaine; Keith, Steven; Herr, Joshua K.; Sutter, Diane; Pettis, Ronald J.
2015-01-01
Background: This study sought to assess the function and delivery reliability of intradermal (ID) infusion sets used with commercial insulin pumps. Method: Healthy subjects (n = 43) were randomized to either ID or subcutaneous (SC) arms, and received basal/bolus placebo delivery for 24 hours. Subjects received 4 of 8 infusion set combinations (ID: microneedle design A or B, with 2 pump brands [Animas or MiniMed]; SC: Teflon Quickset or steel Rapid-D, Animas pump only, with or without overtaping) and were evaluated for pump occlusion alarms, fluid leakage, pain, and tissue tolerability. A novel algorithm was developed to determine flow consistency based on fluid pressure, and the duration and occurrence rate for periods of unalarmed but interrupted flow (“silent occlusions’”) were compared. Results: ID delivery was successfully maintained over the 24-hour infusion period. The number of silent occlusions was lower for ID microneedle cannula design B than A (P < .01) and lower for Rapid-D SC device compared to Quick-set (P = .03). There was no significant difference in the number of occlusion alarms between the ID and SC devices with the Animas pump. However, the pumps tested with ID devices had significantly different alarm rates (MiniMed 29.5%, Animas 0%, P < .001). Leakage and tissue tolerability were comparable across devices. Conclusion: The ID infusion set reliably delivered diluent for an extended 24-hour period in healthy subjects and was well tolerated. Silent occlusion flow interruptions could be detected in both ID and SC infusion sets using a proprietary algorithm. This algorithm is a promising method for quantitatively evaluating infusion set flow performance. PMID:26319228
Lama, Daniel J; Owyong, Michael; Parkhomenko, Egor; Patel, Roshan M; Landman, Jaime; Clayman, Ralph V
2018-05-01
To evaluate the flow characteristics produced by a manual and automated-pump irrigation system connected to a flexible ureteroscope. An in vitro analysis of a manual hand-pump infuser (HP) and the UROMAT Endoscopic Automatic System for Irrigation ® (E.A.S.I.) pump was performed. Standard irrigation tubing was used to connect a three-way valve to a flexible ureteroscope, the irrigation system, and a digital manometer. Flow rate and irrigation pressure measurements were recorded over a 15-minute period using pressure settings of 150 and 200 mm Hg for both irrigation pump systems. Once the HP was inflated to the initial pressure, it was not reinflated over the course of the trial. Data were collected with the working channel unoccupied and with placement of a 200 μm (0.6F) holmium laser fiber, 1.7F nitinol stone retrieval basket, or 2.67F guidewire. The difference in pressure measured at the site of inflow of irrigation to the ureteroscope was significantly greater using the HP compared to the E.A.S.I. pump at pressure settings of 150 mm Hg with and without the use of ureteroscopic instrumentation (p < 0.001), and at 200 mm Hg with instrumentation in the working channel (p < 0.01). There was no significant difference in the flow rate of irrigation through the open-channel ureteroscope over the course of 5 minutes between the two pump systems. The flow rates of irrigation produced by the HP and the E.A.S.I. pump are similar at pressures of 150 and 200 mm Hg irrespective of the occupancy of a ureteroscope's working channel during the first 5-minutes of irrigation. Irrigation pressure at the entry site of the ureteroscope is subject to significant variability with use of the HP compared to the E.A.S.I. pump irrigation system.
Development of the Baylor-Nikkiso centrifugal pump with a purging system for circulatory support.
Naito, K; Miyazoe, Y; Aizawa, T; Mizuguchi, K; Tasai, K; Ohara, Y; Orime, Y; Glueck, J; Takatani, S; Noon, G P
1993-07-01
The Baylor-Nikkiso centrifugal pump is a magnetically coupled system with a V-ring seal separating the pump and the actuator chamber. To prevent thrombus formation behind the impeller and to extend the life of the pump to 2 weeks of continuous operation, we incorporated a purging chamber behind the V-ring seal. An external pump connected to this purging chamber infused fluid at a constant rate to wash the shaft-seal area. To evaluate the effectiveness of the purging system, we have carried out biventricular bypass experiments using calves. The purging system was successful in reducing the level of thrombus formation after 2 weeks of operation. The results of these studies confirmed that the Baylor-Nikkiso centrifugal pump with this purging system is suitable for at least 2 weeks of continuous operation as a circulatory support system.
Physical and Chemical Stability of Urapidil in 0.9% Sodium Chloride in Elastomeric Infusion Pump.
Tomasello, Cristina; Leggieri, Anna; Rabbia, Franco; Veglio, Franco; Baietto, Lorena; Fulcheri, Chiara; De Nicolò, Amedeo; De Perri, Giovanni; D'Avolio, Antonio
2016-01-01
Urapidil is an antihypertensive agent, usually administered through intravenous bolus injection, slow-intravenous infusion, or continuous-drug infusion by perfusor. Since to date no evidences are available on drug stability in elastomeric pumps, patients have to be hospitalized. The purpose of this study was to validate an ultra-performance liquid chromatographic method to evaluate urapidil stability in an elastomeric infusion pump, in order to allow continuous infusion as home-care treatment. Analyses were conducted by diluting urapidil in an elastomeric pump. Two concentrations were evaluated: 1.6 mg/mL and 3.3 mg/mL. For the analyses, a reverse-phase ultra-performance liquid chromatographic- photodiode array detection instrument was used. Stressed degradation, pH changes, and visual clarity were used as stability indicators up to 10 days after urapidil solution preparation. The drug showed no more than 5% degradation during the test period at room temperature. No pH changes and no evidences of incompatibility were observed. Stress tests resulted in appreciable observation of degradation products. Considering the observed mean values, urapidil hydrochloride in sodium chloride 0.9% in elastomeric infusion pumps is stable for at least 10 days. These results indicate that this treatment could be administered at home for a prolonged duration (at least 7 days) with a satisfactory response. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Chavez-Abraham, Victor; Barr, Jason S; Zwiebel, Paul C
2011-08-01
Postoperative pain management following aesthetic plastic surgery traditionally has been achieved by systemic administration of several narcotic pain medications. Because this method can lead to undesirable side effects such as sedation, nausea, vomiting, and respiratory depression, a more efficacious method of postoperative analgesia with fewer side effects needs to be implemented in outpatient cosmetic surgery. From March of 2003 until December of 2008, 690 patients underwent augmentation mammaplasty and 215 patients underwent abdominoplasty. All of these patients were equipped with an elastomeric continuous infusion pump postoperatively and were prescribed oral narcotics. Prior to 2003, patients were prescribed only oral narcotics postoperatively. A retrospective chart review of patients before and after implementation of the pain pump was undertaken to review the perceived pain patients experienced postoperatively with and without the pump. The self-administration of oral narcotics was also assessed. Patients equipped with the pain pump experienced a statistically significant decrease in perceived pain compared to those without the pump (augmentation mammaplasty: 2.27 vs. 3.68, p < 0.05; abdominoplasty: 2.81 vs. 4.32, p < 0.05). Similarly, patients with the pump saw a statistically significant decrease in the use of the oral narcotic Vicodin™ at 72 h postoperatively (5 mg hydrocodone/500 mg acetaminophen, Abbott Laboratories, Abbott Park, IL) (augmentation mammaplasty: 26.5 mg/2650 mg vs. 49 mg/4900 mg, p < 0.01; abdominoplasty: 29.5 mg/2950 mg vs. 56.5 mg/5650 mg, p < 0.01). The utilization of a continuous-infusion pain pump following augmentation mammaplasty or abdominoplasty is an efficacious method to significantly reduce both the amount of pain patients experience and the quantity of narcotics used postoperatively.
Accuracy and consistency of drop delivery in infusion pumps.
Yau, K I; Miyasaka, K
1990-04-01
Advances in intensive care medicine has made us more depend on infusion pumps to deliver accurate amounts of fluids to sick newborns, children and adults. When infusing rapid-acting critical drugs to patients, it is important not only to deliver accurate fluid-volume amounts over a specified time, but also to deliver the fluid at a constant rate with minimal fluctuation. The accuracy of drop delivery in four infusion pumps (IVAC 530, IVAC 560, IMED 922 and IMED 960) at different infusion rates were examined in a laboratory setting by using a photoelectric sensor and a computer. When it was not in its cassette-filling period, the IMED 960 was the most accurate at delivering fluid-drops, with a coefficient of variance (CV) of less than 10% at each flow rate. Yet, like other piston-cylinder cassette pumps, its cassette filling time and stabilizing period after cassette filling were longer at lower flow rates. Both the IVAC 530 and the IMED 922 delivered fluids irregularly with large coefficients of variance (CVs). IVAC 560 had the best results for consistency of drop-delivery over a 4-hour period.
Insulin Infusion Set: The Achilles Heel of Continuous Subcutaneous Insulin Infusion
Heinemann, Lutz; Krinelke, Lars
2012-01-01
Continuous subcutaneous insulin infusion from an insulin pump depends on reliable transfer of the pumped insulin to the subcutaneous insulin depot by means of an insulin infusion set (IIS). Despite their widespread use, the published knowledge about IISs and related issues regarding the impact of placement and wear time on insulin absorption/insulin action is relatively small. We also have to acknowledge that our knowledge is limited with regard to how often patients encounter issues with IISs. Reading pump wearer blogs, for instance, suggests that these are a frequent source of trouble. There are no prospective clinical studies available on current IIS and insulin formulations that provide representative data on the type and frequency of issues with infusion sets. The introduction of new IISs and patch pumps may foster a reassessment of available products and of patient problems related to their use. The aim of this review is to summarize the current knowledge and recommendations about IISs and to highlight potential directions of IIS development in order to make insulin absorption safer and more efficient. PMID:22920824
Comparison of peristaltic and Venturi pumps in bimanual microincisional cataract surgery.
Karaguzel, Hande; Karalezli, Aylin; Aslan, Bekir Sitki
2009-12-01
Comparison of peristaltic and Venturi pumps in bimanual microincision phacoemulsification on the success of the cataract surgery by using sleeveless phaco tip. Bimanual microincision phacoemulsification was done in 49 eyes using a 1.4-mm temporal clear corneal incision. A peristaltic pump was used in 23 eyes, and a Venturi pump was used in 26 eyes for phacoemulsification. Intraoperative complications, anterior chamber stability, and mean duration of surgery were recorded. Duration of surgery was shorter in the Venturi pump group. Anterior chamber stability could not be established in 17 eyes in the peristaltic pump group; it was established in all eyes in the Venturi pump group. Corneal burns were observed in two eyes in the peristaltic pump group and no eyes in the Venturi pump group. Use of a Venturi pump system and a vented gas-forced infusion system can significantly shorten surgery time and reduce risk of thermal burns.
Accuracy of intravenous infusion pumps in continuous renal replacement therapies.
Jenkins, R; Harrison, H; Chen, B; Arnold, D; Funk, J
1992-01-01
Most extracorporeal continuous renal replacement therapies (CRRT) require inflow pumping of either dialysate, filtrate replacement solution, or both. Outflow of spent dialysate and ultrafiltrate can be accomplished by gravity drainage or pump. Intravenous infusion pumps have been commonly used for these purposes, although little is known about the accuracy of these pumps. To evaluate accuracy of two different types of intravenous infusion pumps used in CRRT, we studied flow rates at nine different pressure variations in three piston type and three linear peristaltic pumps. The results showed that error of either pump was not different for flow rates of 4 and 16 ml/min. Both types of pumps were affected by fluid circuit pressures, although pressure conditions under which error was low were different for each pump type. The linear peristaltic pumps were most accurate under conditions of low pump inlet pressure, whereas piston pumps were most accurate under conditions of low pump pressure gradient (outlet minus inlet) of 0 or -100 mmHg. The magnitude of error outside these conditions was substantial, reaching 12.5% for the linear peristaltic pump when inlet pressure was -100 mmHg and outlet pressure was 100 mmHg. Error may be minimized in the clinical setting by choosing the pump type best suited for the pressure conditions expected for the renal replacement modality in use.
The properties of an improvised piston pump for the rapid delivery of intravenous fluids.
Smart, C M; Primrose, C W; Peters, A L; Speirits, E J
2014-02-01
To maximise the effect of a small fluid load, it is occasionally desirable to bolus manually with multiple depressions of a large-capacity syringe. This is usually achieved by placing the syringe on the side port of a three-way tap. We modified this technique by placing two-one-way valves in line with the three-way tap, effectively creating a piston pump, the infusion rates via which we compared with those achieved by an inflatable pressure-infuser in a simulated resuscitation. Fluid flow was faster using the piston pump than with the pressure-infuser (mean (SD) time to infuse 2000 ml saline 0.9% via a 16-G cannula 352 (10) s vs 495 (19) s, respectively, p < 0.0001). The piston pump appears to have potential for both tight control of fluid delivery and major high-volume resuscitation. The lightweight nature of the pump and its lack of reliance on gravity may also make it suitable for the pre-hospital setting. © 2014 The Association of Anaesthetists of Great Britain and Ireland.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-21
... infusion pump stand, which is currently classified as a class I device because it supports the intended use of an infusion pump (class II medical device). A mobile medical app that simply supports the intended...
Analysis of the Environmental Impact of Insulin Infusion Sets Based on Loss of Resources with Waste
Pfützner, Andreas; Musholt, Petra B; Malmgren-Hansen, Bjoern; Nilsson, Nils H; Forst, Thomas
2011-01-01
Insulin pump therapy [continuous subcutaneous insulin infusion (CSII)] requires regular change of infusion sets every 2-3 days in order to minimize the risk of skin irritations or other adverse events. This has been discussed to be a potential burden to the environment. The purpose of this analysis was to perform an environmental assessment of insulin pump infusion sets based on loss of resources occurring during incineration of the discarded products and by means of a lifecycle concept used to weight a material in relation to its rareness on earth and its consumption. In addition to five infusion sets (Inset30, InsetII, Comfort, Quick-set, and Cleo), a patch pump (Omnipod) was also included in this analysis. The annual loss in waste of the so called “person reserve” of 3 days of catheter use was compared with daily consumption of a cup of coffee in a disposable paper cup and to a soft drink in an aluminum can. The weight-based loss in resources through waste for the infusion sets (except for Cleo) corresponded to 70-200% of the loss of resources for a coffee cup (Cleo, 320%; Omnipod, 1,821,600%) and to 1-3% of the loss from an aluminum soft drink can (Cleo, 5%; Omnipod, 31,200%). The loss or resources by use of infusion sets used in insulin pump therapy appears to be low and is similar to the burden induced by the uptake of one cup of coffee per day. The loss or resources with regular CSII is considerably lower than the loss or resources induced by patch pumps. PMID:21880223
Harding, Andrew D
2012-01-01
The use of infusion pumps that incorporate "smart" technology (smart pumps) can reduce the risks associated with receiving IV therapies. Smart pump technology incorporates safeguards such as a list of high-alert medications, soft and hard dosage limits, and a drug library that can be tailored to specific patient care areas. Its use can help to improve patient safety and to avoid potentially catastrophic harm associated with medication errors. But when one independent community hospital in Massachusetts switched from older mechanical pumps to smart pumps, it neglected to assign an "owner" to oversee the implementation process. One result was that nurses were using the smart pump library for only 37% of all infusions.To increase pump library usage percentage-thereby reducing the risks associated with infusion and improving patient safety-the hospital undertook a continuous quality improvement project over a four-month period in 2009. With the involvement of direct care nurses, and using quantitative data available from the smart pump software, the nursing quality and pharmacy quality teams identified ways to improve pump and pump library use. A secondary goal was to calculate the hospital's return on investment for the purchase of the smart pumps. Several interventions were developed and, on the first of each month, implemented. By the end of the project, pump library usage had nearly doubled; and the hospital had completely recouped its initial investment.
A gravimetric technique for evaluating flow continuity from two infusion devices.
Leff, R D; True, W R; Roberts, R J
1987-06-01
A computerized gravimetric technique for examining the flow continuity from infusion devices was developed, and two infusion devices with different mechanisms of pump operation were evaluated to illustrate this technique. A BASIC program that records serial weight measurements and calculates weight change from previous determinations was written for and interfaced with a gravimetric balance and IBM PC. A plot of effused weight (normalized weight change that reflects the difference between desired timed-sample interval and actual time) versus time (desired timed-sample interval) was constructed. The gravimetric technique was evaluated using both a peristaltic-type and a piston-type infusion pump. Intravenous solution (5% dextrose and 0.9% sodium chloride) was effused at 10 mL/hr and collected in a beaker. Weights were measured at 10-second intervals over a two-hour infusion period, and the weights of the effused solution were plotted versus time. Flow continuity differed between the two infusion devices. Actual effused weight decreased to 0.007 g/10 sec during the refill cycle of the piston-type pump; the mean (+/- S.D.) effused weight was 0.029 +/- 0.002 g/10 sec. The desired effusion rate was 0.028 g/10 sec. The peristaltic pump had greater flow continuity, with a mean effusion weight of 0.028 +/- 0.003 g/10 sec. The gravimetric technique described in this report can be used to quantitatively depict the effusion profiles of infusion devices. Further studies are needed to identify the degree of flow continuity that is clinically acceptable for infusion devices.
A Wireless Implantable Micropump for Chronic Drug Infusion Against Cancer
Cobo, Angelica; Sheybani, Roya; Tu, Heidi; Meng, Ellis
2016-01-01
We present an implantable micropump with a miniature form factor and completely wireless operation that enables chronic drug administration intended for evaluation and development of cancer therapies in freely moving small research animals such as rodents. The low power electrolysis actuator avoids the need for heavy implantable batteries. The infusion system features a class E inductive powering system that provides on-demand activation of the pump as well as remote adjustment of the delivery regimen without animal handling. Micropump performance was demonstrated using a model anti-cancer application in which daily doses of 30 μL were supplied for several weeks with less than 6% variation in flow rate within a single pump and less than 8% variation across different pumps. Pumping under different back pressure, viscosity, and temperature conditions were investigated; parameters were chosen so as to mimic in vivo conditions. In benchtop tests under simulated in vivo conditions, micropumps provided consistent and reliable performance over a period of 30 days with less than 4% flow rate variation. The demonstrated prototype has potential to provide a practical solution for remote chronic administration of drugs to ambulatory small animals for research as well as drug discovery and development applications. PMID:26855476
Smale, Andrew; Tsouras, Theo
2017-01-01
We present a standardized test methodology and results for our evaluation of the Carefusion Alaris PC infusion pump, comprising the model 8015 PC Unit and the model 8100 Large Volume Pump (LVP) module. The evaluation consisted of basic suitability testing, internal component inspection, surface temperature measurement of selected internal components, and critical performance testing (infusion rate accuracy and occlusion alarm pressure) during conditions of typical hyperbaric oxygen (HBO₂) treatment in our facility's class A multiplace chamber. We have found that the pumps pose no enhanced risk as an ignition source, and that the pumps operate within manufacturer's specifications for flow rate and occlusion alarms at all stages of HBO₂ treatments, up to 4.0 ATA and pressurization and depressurization rates up to 180 kPa/minute. The pumps do not require purging with air or nitrogen and can be used unmodified, subject to the following conditions: pumps are undamaged, clean, fully charged, and absent from alcohol cleaning residue; pumps are powered from the internal NiMH battery only; maximum pressure exposure 4.0 ATA; maximum pressurization and depressurization rate of 180 kPa/minute; LVP modules locked in place with retaining screws. Copyright© Undersea and Hyperbaric Medical Society.
Birch, K; Hildebrandt, P; Jensen, B M; Kühl, C; Brange, J
1985-05-01
To compare the metabolic control and the pharmacokinetics of infused insulin using an insulin pump (Auto-Syringe AS 6C) which provides the basal rate in pulses every 2-10 min with a pump (Medix Syringe Driver 209) providing the basal rate in pulses every 15-60 min, 6 C-peptide negative diabetic patients received, in random order, identical, but individual, insulin treatment during one 4-day period using the Auto-Syringe pump and another 4-day period using the Medix pump. On the fourth day of each period, blood glucose and plasma-free insulin were estimated every 30 min for 7 hr and every 5 min for the next hour. Plasma-free insulin was significantly higher on 3 time points out of the 26 possible when using the Medix pump, but this was not reflected in the blood glucose concentrations which were similar in the 2 periods. The results indicate that, from a metabolic and pharmacokinetic point of view, insulin pumps working with larger intervals between the basal rate pulses are just as good as the more technically advanced and hence often more expensive pumps which provide the basal rate in more and smaller pulses.
Borot, Sophie; Franc, Sylvia; Cristante, Justine; Penfornis, Alfred; Benhamou, Pierre-Yves; Guerci, Bruno; Hanaire, Hélène; Renard, Eric; Reznik, Yves; Simon, Chantal
2014-01-01
The JewelPUMP™ (JP) is a new patch pump based on a microelectromechanical system that operates without any plunger. The study aimed to evaluate the infusion accuracy of the JP in vitro and in vivo. For the in vitro studies, commercially available pumps meeting the ISO standard were compared to the JP: the MiniMed® Paradigm® 712 (MP), Accu-Chek® Combo (AC), OmniPod® (OP), Animas® Vibe™ (AN). Pump accuracy was measured over 24 hours using a continuous microweighing method, at 0.1 and 1 IU/h basal rates. The occlusion alarm threshold was measured after a catheter occlusion. The JP, filled with physiological serum, was then tested in 13 patients with type 1 diabetes simultaneously with their own pump for 2 days. The weight difference was used to calculate the infused insulin volume. The JP showed reduced absolute median error rate in vitro over a 15-minute observation window compared to other pumps (1 IU/h): ±1.02% (JP) vs ±1.60% (AN), ±1.66% (AC), ±2.22% (MP), and ±4.63% (OP), P < .0001. But there was no difference over 24 hours. At 0.5 IU/h, the JP was able to detect an occlusion earlier than other pumps: 21 (19; 25) minutes vs 90 (85; 95), 58 (42; 74), and 143 (132; 218) minutes (AN, AC, MP), P < .05 vs AN and MP. In patients, the 24-hour flow error was not significantly different between the JP and usual pumps (–2.2 ± 5.6% vs –0.37 ± 4.0%, P = .25). The JP was found to be easier to wear than conventional pumps. The JP is more precise over a short time period, more sensitive to catheter occlusion, well accepted by patients, and consequently, of potential interest for a closed-loop insulin delivery system. PMID:25079676
NASA Technical Reports Server (NTRS)
Fischell, Robert E. (Inventor)
1986-01-01
A medication infusion system provides redundant safety and includes condition detecting and informational alarm signal generating apparatus for indicating if (1) a fluid leak occurs in different portions of the system; (2) a programmable input from a patient or physician would result in exceeding a safe dosage limit; (3) the reservoir containing medication has been filled; (4) the intended medication pumping does not correlate with the pumping actually effected; (5) battery voltage is low; (6) the medication reserve is low; and (7) the system has been switched off. The apparatus may provide subcutaneous electrical, thermal, or audible stimulation to the patient and also provides a signal which a physician may monitor. The stimulation may be coded to separately identify each above-listed deviation in nominal system performance. In addition, the number of medication requests are correlated with actual medication dispensing to assure proper operation. An identification scheme is provided which matches the patient with his or her corresponding medication.
[Continuous drug infusion in terminal cancer].
Ottesen, S; Manger, A T; Monrad, L
1992-05-30
Today's technology provides portable pumps which facilitate continuous infusion of drugs to relieve suffering in terminal disease. Subcutaneous and epidural infusion is now frequently used in our hospital. The most common indications are gastrointestinal obstruction, impaired absorption of drugs, refractory side effects of oral medication or poor compliance because good pain relief is no longer possible orally. During the last days of life, this method may be the only possible approach to good comfort and relief from terminal agitation and anxiety. Of the patients referred to the advisory group for seriously ill and dying in 1990, 64% received subcutaneous infusions and 15% epidural infusions during the last days or weeks of life. Continuous infusion of drugs from portable pumps has become an almost indispensible method of treatment in an ordinary clinic.
Kawabata, Yoshinori
2012-01-01
FOLFOX6 and FOLFIRI regimens are often selected as the first- or second-line treatment for advanced or recurrent colorectal cancer. Patients are now able to undergo at-home treatment by using a portable disposable infusion pump (SUREFUSER(®)A) for continuous intravenous infusion of 5-fluorouracil (5-FU). The duration of continuous 5-FU infusion is normally set at an average of 46 h, but large variations in the duration of infusion are observed. The relationship between the total volume of the drug solution in SUREFUSER(®)A and the duration of infusion was analyzed by regression analysis. In addition, multiple regression analysis of the total volume of the drug solution, dummy variables for temperature, and duration of infusion was carried out. The duration of infusion was affected by the coefficient of viscosity of the drug solution and the ambient temperature. The composition of the drug solutions and the ambient temperature must be considered to ensure correct duration of continuous infusion.
Siphon effects on continuous subcutaneous insulin infusion pump delivery performance.
Zisser, Howard C; Bevier, Wendy; Dassau, Eyal; Jovanovic, Lois
2010-01-01
The objective was to quantify hydrostatic effects on continuous subcutaneous insulin infusion (CSII) pumps during basal and bolus insulin delivery. We tested CSII pumps from Medtronic Diabetes (MiniMed 512 and 515), Smiths Medical (Deltec Cozmo 1700), and Insulet (OmniPod) using insulin aspart (Novolog, Novo Nordisk). Pumps were filled and primed per manufacturer's instructions. The fluid level change was measured using an inline graduated glass pipette (100 microl) when the pipette was moved in relation to the pump (80 cm Cosmo and 110 cm Medtronics) and when level. Pumps were compared during 1 and 5 U boluses and basal insulin delivery of 1.0 and 1.5 U/h. Pronounced differences were seen during basal delivery in pumps using 80-100 cm tubing. For the 1 U/h rate, differences ranged from 74.5% of the expected delivery when the pumps were below the pipettes and pumping upward to 123.3% when the pumps were above the pipettes and pumping downward. For the 1.5 U/h rate, differences ranged from 86.7% to 117.0% when the pumps were below or above the pipettes, respectively. Compared to pumps with tubing, OmniPod performed with significantly less variation in insulin delivery. Changing position of a conventional CSII pump in relation to its tubing results in significant changes in insulin delivery. The siphon effect in the tubing may affect the accuracy of insulin delivery, especially during low basal rates. This effect has been reported when syringe pumps were moved in relation to infusion sites but has not been reported with CSII pumps. 2010 Diabetes Technology Society.
Absorption of subcutaneously infused insulin: influence of the basal rate pulse interval.
Hildebrandt, P; Birch, K; Jensen, B M; Kühl, C; Brange, J
1985-01-01
Eight insulin-dependent diabetic patients were given two constant infusions (each 1 IU/h) of 125I-labeled insulin into the abdominal subcutaneous tissue for about 12 h. Insulin was infused in pulses into one side of the abdomen in 6-min intervals (by means of an Auto-Syringe pump) and in the other side of the abdomen, insulin was infused in 1-h intervals (by means of a Medix pump). The size of the subcutaneous depots was continuously measured by counting the radioactivity at the infusion sites. After starting the infusions, the two depots were built up to steady-state levels at the same time and of the same size (approximately 3 IU) and with similar absorption rates. Thus, during basal rate insulin infusion, identical insulin absorption kinetics was achieved, irrespective of a 10-fold difference in the pulse rate.
Designing the modern pump: engineering aspects of continuous subcutaneous insulin infusion software.
Welsh, John B; Vargas, Steven; Williams, Gary; Moberg, Sheldon
2010-06-01
Insulin delivery systems attracted the efforts of biological, mechanical, electrical, and software engineers well before they were commercially viable. The introduction of the first commercial insulin pump in 1983 represents an enduring milestone in the history of diabetes management. Since then, pumps have become much more than motorized syringes and have assumed a central role in diabetes management by housing data on insulin delivery and glucose readings, assisting in bolus estimation, and interfacing smoothly with humans and compatible devices. Ensuring the integrity of the embedded software that controls these devices is critical to patient safety and regulatory compliance. As pumps and related devices evolve, software engineers will face challenges and opportunities in designing pumps that are safe, reliable, and feature-rich. The pumps and related systems must also satisfy end users, healthcare providers, and regulatory authorities. In particular, pumps that are combined with glucose sensors and appropriate algorithms will provide the basis for increasingly safe and precise automated insulin delivery-essential steps to developing a fully closed-loop system.
2010-10-01
Due to an issue in manufacturing, downstream occlusion (DSO) sensors in some Smiths Medical CADD-Solis infusion pumps may drift out of calibration, potentially resulting in erroneous alarms that disable the units. Hospitals experiencing the problem should return affected units to Smiths Medical for recalibration (free of charge) and should consider testing all their CADD-Solis pumps during routine maintenance to ensure that they alarm appropriately for downstream occlusions.
Distiller, L A
1983-03-26
In many cases of type I diabetes it is extremely difficult to maintain adequate long-term diabetic control. Over the last decade a better understanding has been gained of the relationship between hyperglycaemia and the onset of diabetic microvascular disease. Because of this new techniques are being developed to improve diabetic control; one of these is the use of portable 'open loop' insulin infusion pumps. The results achieved in the first 11 patients to use the Auto-Syringe AS-6C insulin infusion pump on an outpatient basis for longer than 4 months are described. A highly significant improvement in fasting blood glucose levels, 2-hour postprandial blood glucose levels, mean blood glucose levels, glycosylated haemoglobin levels and mean glycaemic excursions was noted in all patients. No cutaneous complications developed despite the use of indwelling subcutaneous needles for up to 4 days at a time. Patient acceptability was excellent and none of the patients had any problems in adapting to 24-hour pump use. The importance of correct patient selection and continuous home blood glucose monitoring is stressed. Insulin infusion pumps can provide an alternative and highly efficacious means of maintaining excellent diabetic control in a select group of type 1 diabetics. However, it is essential that the physician be trained in the use of these pumps and that adequate back-up services are available.
Olsen, C L; Turner, D S; Iravani, M; Waxman, K; Selam, J L; Charles, M A
1995-01-01
To evaluate the roles of 1) abdominal radiography, 2) a pressure diagnostic procedure (PDP) using a standardized diluent infusion into the catheter sideport, and 3) radiocontrast imaging of the catheter lumen as procedures for diagnosing catheter malfunction in diabetic patients implanted with a programmable intraperitoneal infusion device. Sixteen type I diabetic patients implanted with Infusaid programmable intraperitoneal insulin pumps were studied. The ability of the above three procedures to assist diagnosis of catheter malfunction and distinguish between occlusion and catheter breakage was retrospectively analyzed. Glycated hemoglobin was measured to determine the clinical importance of catheter malfunctions and decreases in pump flow due to insulin aggregation in the pump chamber. Mean glycated hemoglobin levels increased significantly from 8.0 +/- 0.3 to 9.0 +/- 0.4% (P < 0.05) before and after catheter malfunction, but not during pump flow slowdowns. Mean peak pressure during PDP was 1.96 +/- 0.14 psi (P < 0.01 vs. normal) in reversibly occluded catheters and 1.86 +/- 0.35 psi (P < 0.05 vs. normal) in broken catheters, compared with 1.32 +/- 0.23 psi in normal catheters. Decay times during PDP were > 50 s for both reversibly occluded and broken catheters (P < 0.001 vs. normal of 3.6 +/- 0.82 s). Abdominal radiographs and sideport injections of contrast material were used to distinguish the types of broken catheters. Catheter breakage and occlusion are complications in implantable insulin infusion systems and result in metabolic deterioration. The presence of a sideport allows pressure data and radiographic procedures to assist in determining the cause of catheter malfunction. A diagnostic algorithm was generated to improve efficiency in investigating catheter problems.
The first object oriented monitor for intravenous anesthesia.
Cantraine, F R; Coussaert, E J
2000-01-01
To describe the design and implementation of "INFUSION TOOLBOX," a software tool to control and monitor multiple intravenous drug infusions simultaneously using pharmacokinetic and pharmacodynamic principles. INFUSION TOOLBOX has been designed to present a graphical interface. Object Oriented design was used and the software was implemented using Smalltalk, to run on a PC. Basic tools are available to manage patient, drugs, pumps and reports. These tools are the PatientPanel, the DrugPanel, the PumpPanel and the HistoryPanel. The screen is built dynamically. The panels may be collapsed or closed to avoid a crowded display. We also built control panels such as the Target ControlPanel which calculates the best infusion sequence to bring the drug concentration in the plasma compartment to a preset value. Before drug delivery, the user enters the patient's data, selects a drug, enters its dilution factor and chooses a pharmacokinetic model. The calculated plasma concentration is continually displayed and updated. The anesthetist may ask for the history of the delivery to obtain a graphic report or to add events to the logbook. A panel targeting the effect is used when a pharmacodynamic model is known. Data files for drugs, pumps and surgery are upgradable. By creating a resizeable ControlPanel we enable the anesthetist to display the information he wishes, when he wishes it. The available panels are diverse enough to meet the anesthetist needs; they may be adapted to the drug used, pumps used and surgery. It is the anesthetist who builds dynamically its different control screens. By adopting an evolutionary solution model we have achieved considerable success in building our drug delivery monitor. In addition we have gained valuable insight into the anesthesia information domain that will allow us to further enhance and expand the system.
Mougiakakou, Stavroula G; Bartsocas, Christos S; Bozas, Evangelos; Chaniotakis, Nikos; Iliopoulou, Dimitra; Kouris, Ioannis; Pavlopoulos, Sotiris; Prountzou, Aikaterini; Skevofilakas, Marios; Tsoukalis, Alexandre; Varotsis, Kostas; Vazeou, Andrianni; Zarkogianni, Konstantia; Nikita, Konstantina S
2010-05-01
SMARTDIAB is a platform designed to support the monitoring, management, and treatment of patients with type 1 diabetes mellitus (T1DM), by combining state-of-the-art approaches in the fields of database (DB) technologies, communications, simulation algorithms, and data mining. SMARTDIAB consists mainly of two units: 1) the patient unit (PU); and 2) the patient management unit (PMU), which communicate with each other for data exchange. The PMU can be accessed by the PU through the internet using devices, such as PCs/laptops with direct internet access or mobile phones via a Wi-Fi/General Packet Radio Service access network. The PU consists of an insulin pump for subcutaneous insulin infusion to the patient and a continuous glucose measurement system. The aforementioned devices running a user-friendly application gather patient's related information and transmit it to the PMU. The PMU consists of a diabetes data management system (DDMS), a decision support system (DSS) that provides risk assessment for long-term diabetes complications, and an insulin infusion advisory system (IIAS), which reside on a Web server. The DDMS can be accessed from both medical personnel and patients, with appropriate security access rights and front-end interfaces. The DDMS, apart from being used for data storage/retrieval, provides also advanced tools for the intelligent processing of the patient's data, supporting the physician in decision making, regarding the patient's treatment. The IIAS is used to close the loop between the insulin pump and the continuous glucose monitoring system, by providing the pump with the appropriate insulin infusion rate in order to keep the patient's glucose levels within predefined limits. The pilot version of the SMARTDIAB has already been implemented, while the platform's evaluation in clinical environment is being in progress.
Kim, Ernest S.; Gustenhoven, Erich; Mescher, Mark J.; Pararas, Erin E. Leary; Smith, Kim A.; Spencer, Abigail J.; Tandon, Vishal; Borenstein, Jeffrey T.; Fiering, Jason
2014-01-01
Reciprocating microfluidic drug delivery, as compared to steady or pulsed infusion, has unique features which may be advantageous in many therapeutic applications. We have previously described a device, designed for wearable use in small animal models, which periodically infuses then withdraws a sub-microliter volume of drug solution to and from the endogenous fluid of the inner ear. This delivery approach results in zero net volume of liquid transfer while enabling mass transport of compounds to the cochlea by means of diffusion and mixing. We report here on an advanced wearable delivery system aimed at further miniaturization and complex dose protocols. Enhancements to the system include the incorporation of a planar micropump to generate reciprocating flow and a novel drug reservoir which maintains zero net volume delivery and permits programmable modulation of the drug concentration in the infused bolus. The reciprocating pump is fabricated from laminated polymer films and employs a miniature electromagnetic actuator to meet the size and weight requirements of a head-mounted in vivo guinea pig testing system. The reservoir comprises a long microchannel in series with a micropump, connected in parallel with the reciprocating flow network. We characterized in vitro the response and repeatability of the planar pump and compared the results with a lumped element simulation. We also characterized the performance of the reservoir, including repeatability of dosing and range of dose modulation. Acute in vivo experiments were performed in which the reciprocating pump was used to deliver a test compound to the cochlea of anesthetized guinea pigs to evaluate short-term safety and efficacy of the system. These advances are key steps toward realization of an implantable device for long-term therapeutic applications in humans. PMID:24302432
Moulin, D E; Kreeft, J H; Murray-Parsons, N; Bouquillon, A I
1991-02-23
To compare the safety and efficacy of subcutaneous and intravenous infusion of opioid analgesics, a randomised, double-blind, crossover trial was carried out in inpatients. 15 patients with severe cancer pain received two 48 h infusions of hydromorphone--one subcutaneously and one intravenously in randomly allocated order. The study was made double-blind by the use of two infusion pumps throughout; during the active subcutaneous infusion the intravenous pump delivered saline and vice versa. Serial measurements of pain intensity, pain relief, mood, and sedation by means of visual analogue scales showed no clinically or statistically significant difference between the two infusion routes. Side-effects were slight, and the mean number of morphine injections for breakthrough pain did not differ significantly between the routes (4.8 [SD 4.5] for intravenous vs 5.3 [5.6] for subcutaneous). Plasma hydromorphone concentrations measured at 24 h and 48 h of infusion showed stable steady-state pharmacokinetics; the mean bioavailability from subcutaneous infusion was 78% of that with intravenous infusion. Because of the simplicity, technical advantages, and cost-effectiveness of continuous subcutaneous opioid infusion into the chest wall or trunk, intravenous opioid infusion for the management of severe cancer pain should be abandoned.
Brannon, Timothy S
2006-01-01
Continuous infusion intravenous (IV) drugs in neonatal intensive care are usually prepared based on patient weight so that the dose is readable as a simple multiple of the infusion pump rate. New safety guidelines propose that hospitals switch to using standardized admixtures of these drugs to prevent calculation errors during ad hoc preparation. Extended hierarchical task analysis suggests that switching to standardized admixtures may lead to more errors in programming the pump at the bedside.
Brannon, Timothy S.
2006-01-01
Continuous infusion intravenous (IV) drugs in neonatal intensive care are usually prepared based on patient weight so that the dose is readable as a simple multiple of the infusion pump rate. New safety guidelines propose that hospitals switch to using standardized admixtures of these drugs to prevent calculation errors during ad hoc preparation. Extended hierarchical task analysis suggests that switching to standardized admixtures may lead to more errors in programming the pump at the bedside. PMID:17238482
Wu, Chien-Chih; Bai, Chyi-Huey; Huang, Ming-Te; Wu, Chih-Hsiung; Tam, Ka-Wai
2014-01-01
Open inguinal hernia repair is one of the most painful procedures in day surgery. A continuous ambulatory analgesic is thought to reduce postoperative pain when it is applied to the surgical site. The aim of this study is to evaluate the efficacy of local anesthetic infusion pump following open inguinal hernia repair for the reduction of postoperative pain. We conducted a systematic review and meta-analysis of randomized controlled trials (RCTs) that have investigated the outcomes of using an infusion pump for delivering a local anesthetic contrasted to a control group for open inguinal hernia repair. Pain was assessed from Day 1 to Day 5 following the surgery. The secondary outcomes included analgesia use and postoperative complications. We reviewed 5 trials that totaled 288 patients. The analgesic effects of bupivacaine (4 trials) and ropivacaine (one trial) were compared with a placebo group. The pooled mean difference in the score measuring the degree of pain diminished significantly at Day 1 to Day 4 in the experimental group. Two studies have reported that the number of analgesics required also decreased in the experimental group. No bupivacaine-related complication was reported. Our results revealed that applying a local anesthetic infusion pump following inguinal hernia repairs was more efficacious for reducing postoperative pain than a placebo. However, the findings were based on a small body of evidence in which methodological quality was not high. The potential benefits of applying a local anesthetic infusion pump to hernia repair must still be adequately investigated using further RCTs. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Pumps and warmers during amnioinfusion: is either necessary?
Glantz, J C; Letteney, D L
1996-01-01
To determine if there is evidence from published reports that the use of infusion pumps or solution warmers during amnioinfusion is beneficial. We identified all English-language amnioinfusion reports published since 1983 through Medline and references. Fourteen prospective papers with at least 40 subjects were identified. For the amnioinfusion and control groups in each study, odds ratios (OR) were calculated for cesarean delivery, fetal distress, meconium below the cords, low 5-minute Apgar score, and endometritis. Cumulative ORs were calculated using the Mantel-Haenszel inverse variance method. This process was repeated after separation into pump-gravity and warmed-unwarmed groups. Multiple regression analyses were performed. Amnioinfusion improved the ability of the fetus to tolerate labor (fetal distress OR 0.40), decreased the incidence of meconium below the cords (OR 0.16), and decreased the rate of cesarean delivery (OR 0.56). There were no demonstrable benefits associated with the use of warmers or pumps. In multiple regression analysis, infusion pumps were associated with a significantly increased risk of fetal distress (P = .01). The use of amnioinfusion is associated with a decreased risk of fetal distress, meconium below the cords, and cesarean delivery. To date, there is no demonstrable benefit using infusion pumps or solution warmers during amnioinfusion.
NASA Astrophysics Data System (ADS)
Sek Tee, Kian; Sharil Saripan, Muhammad; Yap, Hiung Yin; Fhong Soon, Chin
2017-08-01
With the advancement in microfluidic technology, fluid flow control for syringe pump is always essential. In this paper, a mechatronic syringe pump will be developed and customized to control the fluid flow in a poly-dimethylsiloxane (PDMS) microfluidic device based on a polyimide laminating film. The syringe pump is designed to drive fluid with flow rates of 100 and 1000 μl/min which intended to drive continuous fluid in a polyimide based microfluidic device. The electronic system consists of an Arduino microcontroller board and a uni-polar stepper motor. In the system, the uni-polar stepper motor was coupled to a linear slider attached to the plunger of a syringe pump. As the motor rotates, the plunger pumps the liquid out of the syringe. The accuracy of the fluid flow rate was determined by adjusting the number of micro-step/revolution to drive the stepper motor to infuse fluid into the microfluidic device. With the precise control of the electronic system, the syringe pump could accurately inject fluid volume at 100 and 1000 μl/min into a microfluidic device.
Witte, C; Kunth, M; Rossella, F; Schröder, L
2014-02-28
Xenon is well known to undergo host-guest interactions with proteins and synthetic molecules. As xenon can also be hyperpolarized by spin exchange optical pumping, allowing the investigation of highly dilute systems, it makes an ideal nuclear magnetic resonance probe for such host molecules. The utility of xenon as a probe can be further improved using Chemical Exchange Saturation Transfer using hyperpolarized nuclei (Hyper-CEST), but for highly accurate experiments requires a polarizer and xenon infusion system optimized for such measurements. We present the design of a hyperpolarizer and xenon infusion system specifically designed to meet the requirements of Hyper-CEST measurements. One key element of this design is preventing rubidium runaway, a chain reaction induced by laser heating that prevents efficient utilization of high photon densities. Using thermocouples positioned along the pumping cell we identify the sources of heating and conditions for rubidium runaway to occur. We then demonstrate the effectiveness of actively cooling the optical cell to prevent rubidium runaway in a compact setup. This results in a 2-3-fold higher polarization than without cooling, allowing us to achieve a polarization of 25% at continuous flow rates of 9 ml/min of (129)Xe. The simplicity of this design also allows it to be retrofitted to many existing polarizers. Combined with a direction infusion system that reduces shot-to-shot noise down to 0.56% we have captured Hyper-CEST spectra in unprecedented detail, allowing us to completely resolve peaks separated by just 1.62 ppm. Due to its high polarization and excellent stability, our design allows the comparison of underlying theories of host-guest systems with experiment at low concentrations, something extremely difficult with previous polarizers.
Intracerebroventricular opiate infusion for refractory head and facial pain
Lee, Darrin J; Gurkoff, Gene G; Goodarzi, Amir; Muizelaar, J Paul; Boggan, James E; Shahlaie, Kiarash
2014-01-01
AIM: To study the risks and benefits of intracerebroventricular (ICV) opiate pumps for the management of benign head and face pain. METHODS: SSix patients with refractory trigeminal neuralgia and/or cluster headaches were evaluated for implantation of an ICV opiate infusion pump using either ICV injections through an Ommaya reservoir or external ventricular drain. Four patients received morphine ICV pumps and two patientS received a hydromorphone pump. Of the Four patients with morphine ICV pumps, one patient had the medication changed to hydromorphone. Preoperative and post-operative visual analog scores (VAS) were obtained. Patients were evaluated post-operatively for a minimum of 3 mo and the pump dosage was adjusted at each outpatient clinic visit according to the patient’s pain level. RESULTS: All 6 patients had an intracerebroventricular opiate injection trial period, using either an Ommaya reservoir or an external ventricular drain. There was an average VAS improvement of 75.8%. During the trial period, no complications were observed. Pump implantation was performed an average of 3.7 wk (range 1-7) after the trial injections. After implantation, an average of 20.7 ± 8.3 dose adjustments were made over 3-56 mo after surgery to achieve maximal pain relief. At the most recent follow-up (26.2 mo, range 3-56), VAS scores significantly improved from an average of 7.8 ± 0.5 (range 6-10) to 2.8 ± 0.7 (range 0-5) at the final dose (mean improvement 5.0 ± 1.0, P < 0.001). All patients required a stepwise increase in opiate infusion rates to achieve maximal benefit. The most common complications were nausea and drowsiness, both of which resolved with pump adjustments. On average, infusion pumps were replaced every 4-5 years. CONCLUSION: These results suggest that ICV delivery of opiates may potentially be a viable treatment option for patients with intractable pain from trigeminal neuralgia or cluster headache. PMID:25133146
Rate-controlled analgesia: a laboratory evaluation of a new infusion device.
Currie, J; Owen, H; Ilsley, A H
1990-11-01
We report an evaluation of the Bard Harvard Mini Infuser, one of a new generation of agent-specific intraoperative infusion pumps which are designed for use by the anaesthetist. This pump permits potent intravenous anaesthetic agents to be used in pharmacokinetically designed dosage regimens. The controls are calibrated directly in kg body weight and micrograms per minute rather than the usual settings of ml of solution per hour. The performance was assessed by measuring the volume delivered over given time intervals and all safety functions were tested at least three times. This device was found to be acceptably safe and accurate. Two points to note are that it must be purged every time before it is connected to the intravenous infusion and if an occlusion is suddenly relieved, the patient can receive an 'accidental bolus' of up to 1.18 ml of drug. The main advantage of this pump is that it uses undiluted drug direct from the ampoule and does not require any calculations or dilutions prior to use. However, this restricts its use to drugs with a concentration of 500 mcg/ml and in effect means that it is suitable mainly for infusion of alfentanil.
Synchronization software for automation in anesthesia.
Bressan, Nadja; Castro, Ana; Brás, Susana; Oliveira, Hélder P; Ribeiro, Lénio; Ferreira, David A; Antunes, Luís; Amorim, Pedro; Nunes, Catarina S
2007-01-01
This work presents the development of a software for data acquisition and control (ASYS) on a clinical setup. Similar to the industrial Supervisory Control And Data Acquisition (SCADA) the software assembles a Target Controlled Infusion (TCI) monitoring and supervisory control data in real time from devices in a surgical room. The software is not a full controller since the TCI systems comprehend permanent interaction from the anesthesiologist. Based on pharmacokinetic models, the effect-site and plasma concentrations can be related with the drug dose infused and vice versa. The software determines the infusion rates of the drug which are given as commands to the infusion pumps. This software provides the anesthesiologist with a trustworthy tool for managing a safe and balanced anesthesia. Since it also incorporates the acquisition and display of patients brain signals.
Economic benefits of improved insulin stability in insulin pumps.
Weiss, Richard C; van Amerongen, Derek; Bazalo, Gary; Aagren, Mark; Bouchard, Jonathan R
2011-05-01
Insulin pump users discard unused medication and infusion sets according to labeling and manufacturer's instructions. The stability labeling for insulin aspart (rDNA origin] (Novolog) was increased from two days to six. The associated savings was modeled from the perspective of a hypothetical one-million member health plan and the total United States population. The discarded insulin volume and the number of infusion sets used under a two-day stability scenario versus six were modeled. A mix of insulin pumps of various reservoir capacities with a range of daily insulin dosages was used. Average daily insulin dose was 65 units ranging from 10 to 150 units. Costs of discarded insulin aspart [rDNA origin] were calculated using WAC (Average Wholesale Price minus 16.67%). The cost of pump supplies was computed for the two-day scenario assuming a complete infusion set change, including reservoirs, every two days. Under the six-day scenario complete infusion sets were discarded every six days while cannulas at the insertion site were changed midway between complete changes. AWP of least expensive supplies was used to compute their costs. For the hypothetical health plan (1,182 pump users) the annual reduction in discarded insulin volume between scenarios was 19.8 million units. The corresponding cost reduction for the plan due to drug and supply savings was $3.4 million. From the U.S. population perspective, savings of over $1 billion were estimated. Using insulin that is stable for six days in pump reservoirs can yield substantial savings to health plans and other payers, including patients.
UK service level audit of insulin pump therapy in paediatrics.
Ghatak, A; Paul, P; Hawcutt, D B; White, H D; Furlong, N J; Saunders, S; Morrison, G; Langridge, P; Weston, P J
2015-12-01
To conduct an audit of insulin pump therapy in the UK after the issue of guidelines for the use of continuous subcutaneous insulin infusion by NICE in 2008 (Technology Appraisal 151). All centres in the UK, providing pump services to children and young people were invited to participate in an online audit. Audit metrics were aligned to NICE Technology Appraisal 151 and an electronic data collection tool was used. Of the 176 UK centres identified as providing pump services, 166 (94.3%) participated in the study. A total of 5094 children and young people were identified as using continuous subcutaneous insulin infusion (19% of all paediatric patients with Type 1 diabetes), with a median (range) of 16.9 (0.67-69.4)% per centre. Units had a median of 0.58 consultant sessions, 0.43 full-time equivalent diabetic specialist nurses, and 0.1 full-time equivalent dieticians delivering the pump service. The majority of this time was not formally funded. Families could access 24-h clinical and technical support (83% units), although the delivery varied between consultant, diabetic specialist nurse and company representatives. Only 53% of units ran, or accessed, structured education programmes for continuous subcutaneous insulin infusion use. Most units (86%) allowed continuous subcutaneous insulin infusion use for paediatric inpatients, but only 56% had written guidelines for this scenario. Nine percent of units had encountered funding refusal for a patient fulfilling NICE (Technology Appraisal 151) criteria. The number of children and young people on continuous subcutaneous insulin infusion therapy is consistent with numbers estimated by NICE. There is a worrying lack of funded healthcare professional time. The audit also identified gaps in the provision of structured education and absence of written inpatient guidelines. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.
Administration of drugs by infusion pumps in palliative medicine.
Thorsen, A B; Yung, N S; Leung, A C
1994-03-01
A retrospective study was carried out in 100 adult patients with advanced malignant disease. They were given subcutaneous continuous infusions of medication for symptom relief. The drugs were administered through a butterfly needle inserted subcutaneously in the anterior chest wall using a battery-operated infusion pump. The indications for using this technique were inability to swallow due to deteriorating general condition, oesophageal obstruction, intestinal obstruction, severe nausea and vomiting, terminal dyspnoea and poor pain control with oral opiates. All patients received morphine; other drugs administered through the syringe driver included hyoscine, metoclopramide, cyclizine, dexamethasone and midazolam. Ninety-four patients continued subcutaneous infusion until death. The mean duration of treatment was 9.1 days. The treatment was well tolerated by the patients and controlled their symptoms satisfactorily in the great majority. The use of continuous subcutaneous infusion via a syringe driver gives good symptom control. In the last days of life when the patients have difficulty tolerating oral medication, continuous subcutaneous infusion is a superior alternative to frequent intermittent parenteral injections.
Implantation of programmable infusion pumps for insulin delivery in type I diabetic patients.
Walter, H; Günther, A; Kronski, D; Flaschenträger, T; Mehnert, H
1989-06-01
Five type I diabetic patients were followed prospectively during treatment with continuous subcutaneous insulin infusion by externally worn pumps and during the first 12 months after implantation of a remote-controlled insulin infusion device (ID1, Siemens AG). Stabilized insulin (Hoe 21 GH, Hoechst AG) was infused intravenously in two and intraperitoneally in three patients. Total observation time was 47.2 patient-months after implantation. Two devices had to be explanted prematurely, one because of a technical failure after 101 days, one due to a skin necrosis over the implant after 236 days. HbA1, frequency of hypoglycemia, total insulin dose, and basal rate infusion did not change after implantation. There was a reduction in the insulin antibodies 6 months after start of intravenous or intraperitoneal insulin delivery. Fasting plasma free insulin levels could be normalized only by intraperitoneal insulin infusion. Although a technical and a surgical problem was observed, our data show the successful implantation and clinical use of programmable dosing devices and stabilized insulin.
Sampson Perrin, Alysa J; Guzzetta, Russell C; Miller, Kellee M; Foster, Nicole C; Lee, Anna; Lee, Joyce M; Block, Jennifer M; Beck, Roy W
2015-05-01
To evaluate the impact of infusion set use duration on glycemic control, we conducted an Internet-based study using the T1D Exchange's online patient community, Glu ( myGlu.org ). For 14 days, 243 electronically consented adults with type 1 diabetes (T1D) entered online that day's fasting blood glucose (FBG) level, the prior day's total daily insulin (TDI) dose, and whether the infusion set was changed. Mean duration of infusion set use was 3.0 days. Mean FBG level was higher with each successive day of infusion set use, increasing from 126 mg/dL on Day 1 to 133 mg/dL on Day 3 to 147 mg/dL on Day 5 (P<0.001). TDI dose did not vary with increased duration of infusion set use. Internet-based data collection was used to rapidly conduct the study at low cost. The results indicate that FBG levels increase with each additional day of insulin pump infusion set use.
Drever, E; Tomlinson, G; Bai, A D; Feig, D S
2016-09-01
To assess the safety and efficacy of pump therapy (continuous subcutaneous insulin infusion; CSII) during labour and delivery in women with Type 1 diabetes. A retrospective cohort study of 161 consecutive Type 1 diabetic pregnancies delivered during 2000-2010 at Mount Sinai Hospital, Toronto, Canada. Capillary blood glucose levels during labour and delivery and time in/out of target (target: 4-6 mmol/l) were compared along with neonatal outcomes for three groups: (1) women on pumps who stayed on pumps during labour (pump/pump n = 31), (2) women on pumps who switched to intravenous (IV) insulin infusion during labour (pump/IVn = 25), and (3) women on multiple daily injections who switched to IV insulin infusion during labour (MDIn = 105). There were no significant differences between the mean or median glucose values during labour and delivery across all three groups, and no significant difference in time spent hypoglycaemic. However, women in the pump/pump group had significantly better glycaemic control as defined by mean glucose (5.5 vs. 6.4 mmol/l; P = 0.01), median glucose (5.4 vs. 6.3 mmol/l; P = 0.02), and more time spent in target (60.9% vs. 39.2%; P = 0.06) compared with women in the pump/IV group (after removing one outlier). This study demonstrates that the continuation of CSII therapy during labour and delivery appears safe and efficacious. Moreover, women who choose to continue CSII have better glucose control during delivery than those who switch to IV insulin, suggesting that it should be standard practice to allow women the option of continuing CSII during labour and delivery. © 2016 Diabetes UK.
Chu, E; Haller, D; Cartwright, T; Twelves, C; Cassidy, J; Sun, W; Saif, M W; McKenna, E; Lee, S; Schmoll, H-J
2014-03-18
Central venous access devices in fluoropyrimidine therapy are associated with complications; however, reliable data are lacking regarding their natural history, associated complications and infusion pump performance in patients with metastatic colorectal cancer. We assessed device placement, use during treatment, associated clinical outcomes and infusion pump performance in the NO16966 trial. Device replacement was more common with FOLFOX-4 (5-fluorouracil (5-FU)+oxaliplatin) than XELOX (capecitabine+oxaliplatin) (14.1% vs 5.1%). Baseline device-associated events and post-baseline removal-/placement-related events occurred more frequently with FOLFOX-4 than XELOX (11.5% vs 2.4% and 8.5% vs 2.1%). Pump malfunctions, primarily infusion accelerations in 16% of patients, occurred within 1.6-4.3% of cycles. Fluoropyrimidine-associated grade 3/4 toxicity was increased in FOLFOX-4-treated patients experiencing a malfunction compared with those who did not (97 out of 155 vs 452 out of 825 patients), predominantly with increased grade 3/4 neutropenia (53.5% vs 39.8%). Febrile neutropenia rates were comparable between patient cohorts±malfunction. Efficacy outcomes were similar in patient cohorts±malfunction. Central venous access device removal or replacement was common and more frequent in patients receiving FOLFOX-4. Pump malfunctions were also common and were associated with increased rates of grade 3/4 haematological adverse events. Oral fluoropyrimidine-based regimens may be preferable to infusional 5-FU based on these findings.
Manrique-Rodríguez, S; Sánchez-Galindo, A C; Fernández-Llamazares, C M; Calvo-Calvo, M M; Carrillo-Álvarez, Á; Sanjurjo-Sáez, M
2016-10-01
To estimate the impact of smart pump implementation in a pediatric intensive care unit in terms of number and type of administration errors intercepted. Observational, prospective study carried out from January 2010 to March 2015 with syringe and great volumen infusion pumps available in the hospital. A tertiary level hospital pediatric intensive care unit. Infusions delivered with infusion pumps in all pediatric intensive care unit patients. Design of a drug library with safety limits for all intravenous drugs prescribed. Users' compliance with drug library as well as number and type of errors prevented were analyzed. Two hundred and eighty-three errors were intercepted during 62 months of study. A high risk drug was involved in 58% of prevented errors, such as adrenergic agonists and antagonists, sedatives, analgesics, neuromuscular blockers, opioids, potassium and insulin. Users' average compliance with the safety software was 84%. Smart pumps implementation has proven effective in intercepting high risk drugs programming errors. These results might be exportable to other critical care units, involving pediatric or adult patients. Interdisciplinary colaboration is key to succeed in this process. Copyright © 2016 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.
De Andres, Jose; Villanueva, Vicente; Palmisani, Stefano; Cerda-Olmedo, German; Lopez-Alarcon, Maria Dolores; Monsalve, Vicente; Minguez, Ana; Martinez-Sanjuan, Vicente
2011-05-01
It is common clinical practice to perform magnetic resonance imaging (MRI) in patients with indwelling programmable intrathecal drug delivery (IDD) systems, although the safety of the procedure has never been documented. We performed a single-center, 3-year, prospective evaluation in patients with a programmable implanted IDD to assess patient discomfort, IDD technical failures, and adverse effects during and after exposure to MRI. Forty-three consecutive patients with an implanted programmable IDD system (SynchroMed® EL Implantable Infusion Pump, Model 8626L-18, and SynchroMed® II Model 8637-20, 8637-40; Medtronic, Inc., Minneapolis, MN) requiring a scheduled MRI evaluation were studied during a 3-year period. All MRI scans were performed with a 1.5-tesla clinical use magnet and a specific absorption rate of no more than 0.9 W/kg. Radiograph control was used to confirm postexposure pump rotor movement and detect system dislocations. IDD system failures, patient satisfaction, and discomfort were recorded. None of the patients experienced signs of drug overinfusion that could lead to hemodynamic, respiratory, or neurologic alterations. Radiologic evaluation after MRI revealed no spatial displacements of the intrathecal catheter tip or body pump, and programmer telemetry confirmed the infusion recovery. Patients' satisfaction after the procedure was high. Performing an MRI scan with the proposed protocol in patients with an implanted Medtronic programmable IDD system resulted in virtually no technical or medical complications. © 2011 International Anesthesia Research Society
... and down to your stomach) using a special infusion pump. The regular and orally disintegrating tablets are ... usually given as a morning dose (given by infusion over 10 to 30 minutes) and then as ...
... hands thoroughly with an antibacterial soap before TPN infusion. Turn on the water, wet your hands and ... pump according to the supplier's instructions. Before the infusion, unclamp the line and flush with saline. Twist ...
Single-dose volume regulation algorithm for a gas-compensated intrathecal infusion pump.
Nam, Kyoung Won; Kim, Kwang Gi; Sung, Mun Hyun; Choi, Seong Wook; Kim, Dae Hyun; Jo, Yung Ho
2011-01-01
The internal pressures of medication reservoirs of gas-compensated intrathecal medication infusion pumps decrease when medication is discharged, and these discharge-induced pressure drops can decrease the volume of medication discharged. To prevent these reductions, the volumes discharged must be adjusted to maintain the required dosage levels. In this study, the authors developed an automatic control algorithm for an intrathecal infusion pump developed by the Korean National Cancer Center that regulates single-dose volumes. The proposed algorithm estimates the amount of medication remaining and adjusts control parameters automatically to maintain single-dose volumes at predetermined levels. Experimental results demonstrated that the proposed algorithm can regulate mean single-dose volumes with a variation of <3% and estimate the remaining medication volume with an accuracy of >98%. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Using Smart Pumps to Understand and Evaluate Clinician Practice Patterns to Ensure Patient Safety
Mansfield, Jennifer; Jarrett, Steven
2013-01-01
Background: Safety software installed on intravenous (IV) infusion pumps has been shown to positively impact the quality of patient care through avoidance of medication errors. The data derived from the use of smart pumps are often overlooked, although these data provide helpful insight into the delivery of quality patient care. Objective: The objectives of this report are to describe the value of implementing IV infusion safety software and analyzing the data and reports generated by this system. Case study: Based on experience at the Carolinas HealthCare System (CHS), executive score cards provide an aggregate view of compliance rate, number of alerts, overrides, and edits. The report of serious errors averted (ie, critical catches) supplies the location, date, and time of the critical catch, thereby enabling management to pinpoint the end-user for educational purposes. By examining the number of critical catches, a return on investment may be calculated. Assuming 3,328 of these events each year, an estimated cost avoidance would be $29,120,000 per year for CHS. Other reports allow benchmarking between institutions. Conclusion: A review of the data about medication safety across CHS has helped garner support for a medication safety officer position with the goal of ultimately creating a safer environment for the patient. PMID:24474836
Insulin Glulisine (rDNA origin) Injection
... the reservoir and change the tubing, needle, and infusion site (spot where the pump is attached to ... body) at least every 48 hours. If the infusion site is red, itchy, or thickened, tell your ...
The Use of Lithium Batteries in Biomedical Devices
1989-06-15
bone growth stimulator (12) implantable sensor (6) drug infusion system (13) neurostimulator (7) gait assist device (14) pain suppressor The preferred...1000-2000 defibrillator 10-80 2000 neurostimulator 10-20 1-5 drug pump 20-50 1-2 tachyarrythmia control 20-100 2 dual cliamber paceinaker 20-100 single
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-26
...] Draft Guidance for Industry and Food and Drug Administration Staff; Total Product Life Cycle: Infusion... the draft guidance document entitled ``Total Product Life Cycle: Infusion Pump--Premarket Notification... this issue of the Federal Register, FDA is announcing a public meeting regarding external infusion...
Ross, P; Gray, A R; Milburn, J; Kumarasamy, I M; Wu, F; Farrand, S; Armishaw, J; Wiltshire, E; Rayns, J; Tomlinson, P; Wheeler, B J
2016-12-01
While there have been many outcome-focussed studies examining insulin pump therapy, only a few have looked at potential adverse events (AEs), with none examining the relationship between AEs and pump/infusion set type, ethnicity or socio-economic status. In addition, current data on the incidence and characteristics of pump-associated AEs are confined to one paediatric centre. We aimed to describe the incidence, characteristics and potential predictors of insulin pump-associated AEs in New Zealand adults and children with T1DM. We approached adults and families of children with T1DM on insulin pumps in four main New Zealand centres. Participants completed a questionnaire examining pump-related issues they had experienced in the preceding 12 months. Response rate was 64 % with 174 of 270 eligible people participating in the study. 84 % of subjects reported one or more AEs, with an overall AE incidence of 3.42 per person/year (95 % CI 3.14, 3.73). An event serious enough to require a hospital presentation occurred in 9.8 %, all but one reporting high ketones or diabetic ketoacidosis (DKA). Set/site problems were the AE most commonly reported (by 53 % of respondents), followed by cutaneous complications (43 %) and pump malfunction (38 %). Few predictors of AEs (of any type) were found; however, a negative binomial regression model found that a longer duration of pumping (p = 0.018) and age <18 years (p = 0.043) were both associated with fewer AEs (all types combined). Insulin pump-associated AEs are very common. However, few variables are predictive of them with no relationships seen with glycaemic control, socio-economic status, pump manufacturer or infusion set type. Based on these findings, AEs should be anticipated in both adults and children, with anticipatory patient education and training recommended for their successful and safe use.
Baxter elastomeric pumps: Weighing as an alternative to visual inspection.
Cusano, Ellen L; Ali, Raafi; Sawyer, Michael B; Chambers, Carole R; Tang, Patricia A
2018-04-01
Purpose Elastomeric pumps are used to administer 46-hour infusions of 5-fluorouracil (5FU). Baxter suggests patients visually monitor their pumps to ensure that infusions are proceeding correctly. This can be confusing and lead to concerns about under- or over-dosing. Baxter has not considered weighing pumps as a validated method for monitoring. This study aims to validate weighing as a more accurate method for patients and healthcare professionals, and describe real life Baxter Infusor™ variability. Methods Patients who had been started on a 46-hour 5FU infusion returned to the clinic approximately 24 h after starting treatment. The pump was weighed on a StarFrit kitchen scale, and date, time, and weights recorded. Patients were asked if they had a preference for weighing or visually inspecting their pump. Results Pumps ( n = 103) were weighed between 17.25 and 27.5 h after connection. The average weight of a pump was 189 g. Of 103 pumps weighed, 99 weighed less than expected, corresponding to average flow rates of 5.69 mL/h over the elapsed time. The expected flow rate is 5 mL/h with 10% variability. Average flow rates within the 17.25- to 27.5-hour window were 4.561 mL/h, which is 8.78% slower than expected, but within the 10% known variability. Forty-seven percent of patients didn't have a preference for either method, but for those who did have a preference, more than twice as many preferred weighing. Conclusion With proper education, weighing Baxter Infusors at home with kitchen scales can be an accepted and objective alternative to the current recommendation of visual inspection.
[How to promote the respect of good infusion practices by meeting health care professionals?].
Le Reste, C; Fiedler, A; Dubois, S; Dewailly, A; Le Du, I; Cogulet, V
2016-05-01
Health care professionals often forget that there are risks associated with infusion therapy even if it is a common care. In order to assess this practice and to draw potential improvement actions, an audit of local gravity-flow intravenous infusion practices was conducted. The audit, based on a grid including 66 items from the medical prescription to the end of the infusion therapy administration, was conducted in the 6 units which use the most gravity-flow intravenous infusion devices. A multidisciplinary working group was created to decide and organize priority corrective measures in order to improve infusion practices and quality of healthcare. The audit enabled to observe 90hours of nurse's practices (96 infusions) and highlighted heterogeneity in infusion, in some cases inappropriate infusion practices and misuse of infusion devices. We found 4 main issues: labelling infusion therapy, training of health care professionals on good practices, support the purchase of infusion pumps and standardize perfusion line. An interactive educational program for nurses (workshops) was organized to enhance the respect of good practices: infusion identification at any time, respect of hygiene rules, flow rate regulation by counting drops, appropriate use of pumps and flow rate regulators. The audit drew up work priorities. The workshops made easier exchanges between professionals and had a warm welcome that's why it is essential to carry on such training. This collaborative approach between pharmacists, nurses, hygienists and biomedical technicians contribute to drug management improvement and promote optimal patient care. Copyright © 2015 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.
Control of intrauterine fluid pressure during operative hysteroscopy.
Shirk, G J; Gimpelson, R J
1994-05-01
To evaluate the safety of a commonly used piston pump that controls the infusion pressure of low-viscosity fluids in a continuous-flow hysteroscopic system during operative hysteroscopy. Consecutive patients requiring operative hysteroscopy. Three hospital facilities in the Midwest. Sequential sample of 250 women who underwent operative hysteroscopy. Endometrial ablations, resection of submucosal or pedunculated uterine leiomyomata with or without endometrial ablation, polyp resections, metroplasty, and lysis of synechiae. The most serious complication of operative hysteroscopy is fluid overload due to intravasation into the patient's vascular system. Low-viscosity fluids were infused by the Zimmer Controlled Distention Irrigation System. The instrument uses a closed-feedback loop to monitor cavity pressure and automatically regulates the flow to maintain the set point pressure. It is designed to operate in a pressure range of 0 to 80 mm Hg and at flows in excess of 450 ml/minute. In 250 operative hysteroscopies no fluid complications occurred when intrauterine pressure was maintained below 80 mm Hg. No clinically significant differences in intravasation were seen in any type of operative hysteroscopy. This controlled mechanical pump system with exact intrauterine pressure measurement reduced many technical difficulties associated with low-viscosity media, and created a safe environment for the media's use in operative hysteroscopy.
Comparison of p.o. or i.v. proton pump inhibitors on 72-h intragastric pH in bleeding peptic ulcer.
Javid, Gul; Zargar, Showkat Ali; U-Saif, Riyaz-; Khan, Bashir Ahmad; Yatoo, Ghulam Nabi; Shah, Altaf Hussain; Gulzar, Ghulam Mohammad; Sodhi, Jaswinder Singh; Khan, Mushtaq Ahmad
2009-07-01
After successful endoscopic hemostasis in bleeding peptic ulcer, addition of proton pump inhibitors reduce the rate of recurrent bleeding by maintaining intragastric pH at neutral level. The aim of the present study was to evaluate the effect of various proton pump inhibitors given through different routes on intragastric pH over 72 h after endoscopic hemostasis in bleeding peptic ulcer. Ninety consecutive patients who had successful endoscopic therapy of bleeding peptic ulcer underwent 72-h continuous ambulatory intragastric pH study, were randomly assigned to receive p.o. omeprazole 80 mg bolus followed by 40 mg every 12 h for 72 h or i.v. 80 mg omeprazole followed by infusion 8 mg/h for 72 h. Oral pantoprazole 80 mg bolus followed by 80 mg every 12 h for 72 h or i.v. 80 mg pantoprazole followed by infusion of 8 mg/h for 72 h. Oral rabeprazole 80 mg bolus followed by 40 mg every 12 h for 72 h or i.v. 80 mg rabeprazole followed by infusion 8 mg/h for 72 h. Five patients received no treatment after successful endoscopic therapy and underwent 72-h pH study. Mean 72-h intragastric pH for p.o. omeprazole was 6.56 versus 6.93 for omeprazole infusion (P = 0.48). Mean 72-h intragastric pH for p.o. pantoprazole was 6.34 versus 6.32 for pantoprazole infusion (P = 0.62). Mean 72-h intragastric pH for rabeprazole p.o. was 6.11 versus 6.18 rabeprazole i.v. (P = 0.55). Mean 72-h pH for the no proton pump inhibitor group was 2.04. There was no significant difference among various proton pump inhibitors given through different routes on raising intragastric pH above 6 for 72 h after successful endoscopic hemostasis in bleeding peptic ulcer.
Yue, Baohua; Brendel, Ron; Lukitsch, Amelia; Prentice, Thomas; Doty, Brian
2017-06-01
Commercial baclofen formulations used with infusion pumps are available at therapeutic concentrations of 0.5-2.0 mg/mL. However, patients who receive higher daily doses of baclofen may benefit from products with greater baclofen concentrations since their refill frequency would be reduced (up to a maximum of 180 days). We evaluated baclofen solubility, baclofen 3 mg/mL intrathecal (IT) formulation stability, and chemical and physical compatibility with Medtronic SynchroMed ® II and Codman Medstream ® programmable IT infusion pumps. For solubility evaluations, baclofen powder was dissolved into isotonic saline and tested at 5°C, 25°C, and 40°C. To demonstrate drug product stability, both physical and chemical stability attributes of baclofen 3 mg/mL in prefilled syringes were evaluated over 36 months with storage at 25°C. For a simulated in-use stability (compatibility) study, a 3 mg/mL baclofen IT formulation was placed in SynchroMed II and Codman Medstream pumps at 37ºC for study durations, and evaluated at different flow rates. Pump effluent was collected at various times and analyzed by high-performance liquid chromatography for baclofen content. On completion of the in-use stability study, pumps exposed to baclofen 3 mg/mL were dissected and visually evaluated for signs of deterioration. Baclofen solubility was found to be 3.2 mg/mL at 5°C, 3.6 mg/mL at 25°C, and 3.9 mg/mL at 40°C. During the 36-month stability study of prefilled syringes stored at 25°C, baclofen content remained unchanged and no precipitation was observed. The simulated in-use pump study performed at 37ºC showed that a baclofen 3 mg/mL IT formulation was stable at different flow rates and throughout different expected residence times for both pump models. Components from both pumps exhibited no noticeable deterioration after exposure to the 3 mg/mL formulation. Baclofen 3 mg/mL IT formulation was stable during long-term storage at 25°C and remained stable under conditions matching those encountered in clinical practice (37°C). © 2016 International Neuromodulation Society.
Rodríguez-Molinero, Alejandro; Pérez-Martínez, David A; Català, Andreu; Cabestany, Joan; Yuste, Antonio
2009-04-01
Most recent therapeutic solutions to treat Parkinson's disease seek continuous administration of dopaminergic agonists, as for example rigotine patches or apomorphine infusion pumps. Such drug-delivery devices are aimed at preventing fluctuations in drug plasma levels, which could cause certain symptoms such as wearing-off periods or dyskinesia. However, we postulate that drug plasma levels should not keep constant, but rather adjust to the varying intensity of the different user's activities. The rationale behind this is that the drug amount appropriate to treat a patient at rest is lower than that required to treat the same patient when engaged in physical activity. We propose dynamic real-time dose adjustment, so that the doses increase as the patient starts performing physical activity, thus preventing off periods such as "freeze" phenomenon, and the doses reduce during the resting periods, thus preventing adverse effects. Small portable movement sensors are currently available, which detect the amount and type of activity in a continuous way. Combining such technology with infusion pumps to produce modified pumps capable of adjusting the infusion rate to the user's activity, seems to be feasible in the short-term.
Cnossen, Fokie; Dieperink, Willem; Bult, Wouter; de Smet, Anne Marie; Touw, Daan J.; Nijsten, Maarten W.
2017-01-01
The objective of this study was to assess the usability benefits of adding a bedside central control interface that controls all intravenous (IV) infusion pumps compared to the conventional individual control of multiple infusion pumps. Eighteen dedicated ICU nurses volunteered in a between-subjects task-based usability test. A newly developed central control interface was compared to conventional control of multiple infusion pumps in a simulated ICU setting. Task execution time, clicks, errors and questionnaire responses were evaluated. Overall the central control interface outperformed the conventional control in terms of fewer user actions (40±3 vs. 73±20 clicks, p<0.001) and fewer user errors (1±1 vs. 3±2 errors, p<0.05), with no difference in task execution times (421±108 vs. 406±119 seconds, not significant). Questionnaires indicated a significant preference for the central control interface. Despite being novice users of the central control interface, ICU nurses displayed improved performance with the central control interface compared to the conventional interface they were familiar with. We conclude that the new user interface has an overall better usability than the conventional interface. PMID:28800617
Tan, Tsung; Watts, Stephanie W.; Davis, Robert Patrick
2011-01-01
Successful drug delivery using implantable pumps may be found in over 12,500 published articles. Their versatility in delivering continuous infusion, intermittent or complex infusion protocols acutely or chronically has made them ubiquitous in drug discovery and basic research. The recent availability of iPRECIO®, a programmable, refillable, and implantable infusion pump has made it possible to carry out quantitative pharmacology (PKPD) in single animals. When combined with specialized catheters, specific administration sites have been selected. When combined with radiotelemetry, the physiologic gold standard, more sensitive and powerful means of detecting drug induced therapeutic, and/or adverse effects has been possible. Numerous application examples are cited from iPRECIO® use in Japan, United States, and Europe with iPRECIO® as an enabling drug delivery device where the refillable and programmability functionality were key benefits. The ability to start/stop drug delivery and to have control periods prior dosing made it possible to have equivalent effects at a much lower dose than previously studied. Five different iPRECIO® applications are described in detail with references to the original work where the implantable, refillable, and programmable benefits are demonstrated with their different end-points. PMID:21863140
Doesburg, Frank; Cnossen, Fokie; Dieperink, Willem; Bult, Wouter; de Smet, Anne Marie; Touw, Daan J; Nijsten, Maarten W
2017-01-01
The objective of this study was to assess the usability benefits of adding a bedside central control interface that controls all intravenous (IV) infusion pumps compared to the conventional individual control of multiple infusion pumps. Eighteen dedicated ICU nurses volunteered in a between-subjects task-based usability test. A newly developed central control interface was compared to conventional control of multiple infusion pumps in a simulated ICU setting. Task execution time, clicks, errors and questionnaire responses were evaluated. Overall the central control interface outperformed the conventional control in terms of fewer user actions (40±3 vs. 73±20 clicks, p<0.001) and fewer user errors (1±1 vs. 3±2 errors, p<0.05), with no difference in task execution times (421±108 vs. 406±119 seconds, not significant). Questionnaires indicated a significant preference for the central control interface. Despite being novice users of the central control interface, ICU nurses displayed improved performance with the central control interface compared to the conventional interface they were familiar with. We conclude that the new user interface has an overall better usability than the conventional interface.
Use of insulin pumps in India: suggested guidelines based on experience and cultural differences.
Kesavadev, Jothydev; Das, Ashok Kumar; Unnikrishnan, Ranjit; Joshi, Shashank R; Ramachandran, Ambady; Shamsudeen, Jisha; Krishnan, Gopika; Jothydev, Sunitha; Mohan, Viswanathan
2010-10-01
All type 1 diabetes mellitus (T1DM) subjects and the majority of type 2 diabetes mellitus (T2DM) subjects at one time or another require insulin to sustain life. Syringes and pens are presently the most popular insulin delivery devices. Though in use for more than 3 decades, insulin pumps are now being more commonly used because of their unique ability to continuously infuse insulin, closely mimicking that of physiological secretion from a normal pancreas. Unlike insulin shots with syringes, pump infusion sites need to be changed less frequently. Scientific evidence from published studies have proven added benefit of insulin pumps in improving quality of life, normalizing sugars in recalcitrant diabetes, improving sexual function, and relieving the intractable pain of neuropathy. In the western world, pumps are commonly used with T1DM subjects, whereas in India 80% of pumpers are T2DM subjects. The success of insulin pump therapy depends on selection of the right candidate, extensive education, motivation, and implementing the sophisticated programs with skill. However, all affordable patients are not ideal candidates for pump therapy because for successful continuation of pump therapy other inclusion criteria should also be fulfilled. Among the other indications discussed are a high level of insulin resistance, brittle diabetes, chronic kidney disease on renal replacement therapy, and continuous glucose monitoring pattern strongly suggesting need for a variable basal insulin infusion rate. In International Diabetes Foundation data released in 2009, estimated diabetes prevalence for 2010 is 285 million, representing 6.4% of the world's adult population, with a prediction that by 2030 the number of people with diabetes will have increased to 438 million. Considering this massive growth in T2DM and its propensity after 10–15 years to lead to an insulin-deficient state, available evidence from studies is a compelling indication not to deny the benefits of continuous subcutaneous insulin infusion in selected T2DM subjects. This article aims at suggesting guidelines based on clinical experience and cultural diversity for India and developing countries.
Use of Insulin Pumps in India: Suggested Guidelines Based on Experience and Cultural Differences
Das, Ashok Kumar; Unnikrishnan, Ranjit; Joshi, Shashank R.; Ramachandran, Ambady; Shamsudeen, Jisha; Krishnan, Gopika; Jothydev, Sunitha; Mohan, Viswanathan
2010-01-01
Abstract All type 1 diabetes mellitus (T1DM) subjects and the majority of type 2 diabetes mellitus (T2DM) subjects at one time or another require insulin to sustain life. Syringes and pens are presently the most popular insulin delivery devices. Though in use for more than 3 decades, insulin pumps are now being more commonly used because of their unique ability to continuously infuse insulin, closely mimicking that of physiological secretion from a normal pancreas. Unlike insulin shots with syringes, pump infusion sites need to be changed less frequently. Scientific evidence from published studies have proven added benefit of insulin pumps in improving quality of life, normalizing sugars in recalcitrant diabetes, improving sexual function, and relieving the intractable pain of neuropathy. In the western world, pumps are commonly used with T1DM subjects, whereas in India 80% of pumpers are T2DM subjects. The success of insulin pump therapy depends on selection of the right candidate, extensive education, motivation, and implementing the sophisticated programs with skill. However, all affordable patients are not ideal candidates for pump therapy because for successful continuation of pump therapy other inclusion criteria should also be fulfilled. Among the other indications discussed are a high level of insulin resistance, brittle diabetes, chronic kidney disease on renal replacement therapy, and continuous glucose monitoring pattern strongly suggesting need for a variable basal insulin infusion rate. In International Diabetes Foundation data released in 2009, estimated diabetes prevalence for 2010 is 285 million, representing 6.4% of the world's adult population, with a prediction that by 2030 the number of people with diabetes will have increased to 438 million. Considering this massive growth in T2DM and its propensity after 10–15 years to lead to an insulin-deficient state, available evidence from studies is a compelling indication not to deny the benefits of continuous subcutaneous insulin infusion in selected T2DM subjects. This article aims at suggesting guidelines based on clinical experience and cultural diversity for India and developing countries. PMID:20807118
Effect of warming and flow rate conditions of blood warmers on red blood cell integrity.
Poder, T G; Pruneau, D; Dorval, J; Thibault, L; Fisette, J-F; Bédard, S K; Jacques, A; Beauregard, P
2016-11-01
Fluid warmers are routinely used to reduce the risk of hypothermia and cardiac complications associated with the infusion of cold blood products. However, warming blood products could generate haemolysis. This study was undertaken to compare the impact of temperature of blood warmers on the per cent haemolysis of packed red blood cells (RBCs) heated at different flow rates as well as non-flow conditions. Infusion warmers used were calibrated at 41·5°C ± 0·5°C and 37·5°C ± 0·5°C. Cold RBC units stored at 4°C in AS-3 (n = 30), aged 30-39 days old, were divided into half units before being allocated under two different scenarios (i.e. infusion pump or syringe). Blood warmers were effective to warm cold RBCs to 37·5°C or 41·5°C when used in conjunction with an infusion pump at flow rate up to 600 ml/h. However, when the warmed blood was held in a syringe for various periods of time, such as may occur in neonatal transfusions, the final temperature was below the expected requirements with measurement as low as 33·1°C. Increasing the flow with an infusion pump increased haemolysis in RBCs from 0·2% to up to 2·1% at a flow rate of 600 ml/h regardless of the warming device used (P < 0·05). No relevant increase of haemolysis was observed using a syringe. The use of a blood warmer adjusted to 41·5°C is probably the best choice for reducing the risk of hypothermia for the patient without generating haemolysis. However, we should be cautious with the use of an infusion pump for RBC transfusion, particularly at high flow rates. © 2016 International Society of Blood Transfusion.
The U.K. service level audit of insulin pump therapy in adults.
White, H D; Goenka, N; Furlong, N J; Saunders, S; Morrison, G; Langridge, P; Paul, P; Ghatak, A; Weston, P J
2014-04-01
The National Institute for Health and Clinical Excellence (NICE) published guidelines for the use of continuous subcutaneous insulin infusion in 2008 (technology appraisal 151). The first U.K.-wide insulin pump audit took place in 2012 with the aim of determining adherence to the guidance issued in NICE technology appraisal 151. The results of the adult service level audit are reported here. All centres providing continuous subcutaneous insulin infusion services to adults with diabetes in the U.K. were invited to participate. Audit metrics were aligned to technology appraisal 151. Data entry took place online using a DiabetesE formatted data collection tool. One hundred and eighty-three centres were identified as delivering adult continuous subcutaneous insulin infusion services in the U.K., of which 178 (97.3%) participated in the audit. At the time of the audit, 13 428 adults were using insulin pump therapy, giving an estimated prevalence of use of 6%. Ninety-three per cent of centres did not report any barriers in obtaining funding for patients who fulfilled NICE criteria. The mean number of consultant programmed activities dedicated to continuous subcutaneous insulin infusion services was 0.96 (range 0-8), mean whole-time equivalent diabetes specialist nurses was 0.62 (range 0-3) and mean whole-time equivalent dietitian services was 0.3 (range 0-2), of which 39, 61 and 60%, respectively, were not formally funded. The prevalence of continuous subcutaneous insulin infusion use in the U.K. falls well below the expectation of NICE (15-20%) and that of other European countries (> 15%) and the U.S.A. (40%). This may be attributable, in part, to lack of healthcare professional time needed for identification and training of new pump therapy users. © 2013 The Authors. Diabetic Medicine © 2013 Diabetes UK.
Jarosz-Chobot, Przemysława
2004-01-01
This paper sums up recently published researches on the continuous subcutaneous insulin infusion (CSII) with the use of insulin pump in children and adolescents with diabetes type 1. Obtaining a balance in the organism metabolism in childhood and adolescence diabetology is nowadays one of the most important rules of the diabetes management in children. One of the modern ways to achieve that goal is the intensive insulin therapy model with use of the insulin pump. In this paper the advantages and disadvantages as well as the indications and contraindications for the CSII in children and adolescents with diabetes are widely discussed.
Clinical review: insulin pump-associated adverse events in adults and children.
Ross, P L; Milburn, J; Reith, D M; Wiltshire, E; Wheeler, B J
2015-12-01
Insulin pumps are a vital and rapidly developing tool in the treatment of type 1 diabetes mellitus in both adults and children. Many studies have highlighted outcomes and assessed their potential advantages, but much of the data on adverse outcomes are limited and often based on outdated technology. We aimed to review and summarize the available literature on insulin pump-associated adverse events in adults and children. A literature search was undertaken using PubMed, EMBASE, and the Cochrane library. Articles were then screened by title, followed by abstract, and full text as needed. A by-hand search of reference lists in identified papers was also utilised. All searches were limited to English language material, but no time limits were used. Current and past literature regarding insulin pump-associated adverse events is discussed, including potential metabolic and non-metabolic adverse events, in particular: pump malfunction; infusion set/site issues; and cutaneous problems. We show that even with modern technology, adverse events are common, occurring in over 40 % of users per year, with a minority, particularly in children, requiring hospital management. Hyperglycaemia and ketosis are now the most common consequences of adverse events and are usually associated with infusion set failure. This differs from older technology where infected infusion sites predominated. This timely review covers all potential insulin pump-associated adverse events, including their incidence, features, impacts, and contributory factors such as the pump user. The importance of ongoing anticipatory education and support for patients and families using this intensive insulin technology is highlighted, which if done well should improve the overall experience of pump therapy for users, and hopefully reduce the incidence and impact of severe adverse events.
[From insulin pump and continuous glucose monitoring to the artificial pancreas].
Apablaza, Pamela; Soto, Néstor; Codner, Ethel
2017-05-01
Technology for diabetes care has undergone major development during recent decades. These technological advances include continuous subcutaneous insulin infusion (CSII), also known as insulin pumps, and real-time continuous glucose monitoring system (RT-CGMS). The integration of CSII and RT-CGMS into a single device has led to sensor-augmented pump therapy and more recently, a technology that has automated delivery of basal insulin therapy, known as hybrid system. These new technologies have led to benefits in attaining better metabolic control and decreasing the incidence of severe hypoglycemia, especially in patients with type 1 diabetes. This review describes the types of technologies currently available or under investigation for these purposes, their benefits and disadvantages, recommendations and the appropriate patient selection for their use. The clinical use of the hybrid system and artificial pancreas seem to be possible in the near future.
"Beyond the Diagnosis" Making the Invisible Patients Visible | NIH MedlinePlus the Magazine
... new sensory room. During his weekly four-hour infusion, his mom puts his pump and medicine in ... has endured (with a smile) more than 400 infusions, 100 flights to a clinical trial, 50 spinal ...
Continuous quality improvement using intelligent infusion pump data analysis.
Breland, Burnis D
2010-09-01
The use of continuous quality-improvement (CQI) processes in the implementation of intelligent infusion pumps in a community teaching hospital is described. After the decision was made to implement intelligent i.v. infusion pumps in a 413-bed, community teaching hospital, drug libraries for use in the safety software had to be created. Before drug libraries could be created, it was necessary to determine the epidemiology of medication use in various clinical care areas. Standardization of medication administration was performed through the CQI process, using practical knowledge of clinicians at the bedside and evidence-based drug safety parameters in the scientific literature. Post-implementation, CQI allowed refinement of clinically important safety limits while minimizing inappropriate, meaningless soft limit alerts on a few select agents. Assigning individual clinical care areas (CCAs) to individual patient care units facilitated customization of drug libraries and identification of specific CCA compliance concerns. Between June 2007 and June 2008, there were seven library updates. These involved drug additions and deletions, customization of individual CCAs, and alterations of limits. Overall compliance with safety software use rose over time, from 33% in November 2006 to over 98% in December 2009. Many potentially clinically significant dosing errors were intercepted by the safety software, prompting edits by end users. Only 4-6% of soft limit alerts resulted in edits. Compliance rates for use of infusion pump safety software varied among CCAs over time. Education, auditing, and refinement of drug libraries led to improved compliance in most CCAs.
New-generation diabetes management: glucose sensor-augmented insulin pump therapy
Cengiz, Eda; Sherr, Jennifer L; Weinzimer, Stuart A; Tamborlane, William V
2011-01-01
Diabetes is one of the most common chronic disorders with an increasing incidence worldwide. Technologic advances in the field of diabetes have provided new tools for clinicians to manage this challenging disease. For example, the development of continuous subcutaneous insulin infusion systems have allowed for refinement in the delivery of insulin, while continuous glucose monitors provide patients and clinicians with a better understanding of the minute to minute glucose variability, leading to the titration of insulin delivery based on this variability when applicable. Merging of these devices has resulted in sensor-augmented insulin pump therapy, which became a major building block upon which the artificial pancreas (closed-loop systems) can be developed. This article summarizes the evolution of sensor-augmented insulin pump therapy until present day and its future applications in new-generation diabetes management. PMID:21728731
New-generation diabetes management: glucose sensor-augmented insulin pump therapy.
Cengiz, Eda; Sherr, Jennifer L; Weinzimer, Stuart A; Tamborlane, William V
2011-07-01
Diabetes is one of the most common chronic disorders with an increasing incidence worldwide. Technologic advances in the field of diabetes have provided new tools for clinicians to manage this challenging disease. For example, the development of continuous subcutaneous insulin infusion systems have allowed for refinement in the delivery of insulin, while continuous glucose monitors provide patients and clinicians with a better understanding of the minute to minute glucose variability, leading to the titration of insulin delivery based on this variability when applicable. Merging of these devices has resulted in sensor-augmented insulin pump therapy, which became a major building block upon which the artificial pancreas (closed-loop systems) can be developed. This article summarizes the evolution of sensor-augmented insulin pump therapy until present day and its future applications in new-generation diabetes management.
Arranz Martín, Alfonso; Calle Pascual, Alfonso; Del Cañizo Gómez, Francisco Javier; González Albarrán, Olga; Lisbona Gil, Arturo; Botella Serrano, Marta; Pallardo Sánchez, Luis Felipe
2015-04-01
To analyze the available information about continuous subcutaneous insulin infusion (CSII) and continuous glucose monitoring (CGM) systems in the public health care system of the Community of Madrid. A survey consisting of 31 items was sent to the 28 endocrinology department of the Madrid public hospitals. Items focused on CSII and CGM and included patients' registrations, as well as data regarding healthcare, administrative, and logistic aspects. Responses from a total of 20 hospitals where these procedures are used were received from March 2013 to May 2014. Data about pediatric patients were obtained from adult endocrinology departments, except for two hospitals which directly reported the information. A total of 1256 CSII pumps were recorded in the Madrid region, of which 1089 were used by adults, and the remaining 167 by pediatric patients. During 2013, 151 new CSII systems were implanted (12% of the total), while 14 pumps were withdrawn. Availability of human resources (medical assistance) and the number of staff practitioners experienced in management of these systems widely varied between hospitals. Eighty-five percent of hospitals used retrospective CGM systems, and 40% routinely placed them before starting an insulin pump. Thirteen hospitals (65%) used long-term, real-time CGM systems in selected cases (a total of 67 patients). Use of these technologies in diabetes is unequal between public health care hospitals in Madrid, and is still significantly lower as compared to other countries with similar incomes. However, there appears to be a trend to an increase in their use. Copyright © 2014 SEEN. Published by Elsevier España, S.L.U. All rights reserved.
Continuous subcutaneous insulin infusion: Special needs for children.
Adolfsson, Peter; Ziegler, Ralph; Hanas, Ragnar
2017-06-01
Continuous subcutaneous insulin infusion (CSII) is a very common therapy for children with type 1 diabetes. Due to physiological differences they have other requirements for their insulin pump than adults. The main difference is the need for very low basal rates. Even though most available insulin pumps reach a high accuracy at usual basal rates, accuracy decreases for lower rates. In addition, the lowest delivered amount at 1 time is limiting the fine tuning of the basal rate as well as the option for temporary basal rates. Alarms in case of occlusions depend on accumulation of a certain amount of insulin in the catheter, and therefore the time until such an alarm is triggered is much longer with lower basal rates. Accordingly, the risk for hyperglycemia developing into diabetic ketoacidosis increases. The availability of bolus advisors facilitates the calculation of meal and correction boluses for children and their parents. However, there are some differences between the calculators, and the settings that the calculation is based on are very important. Better connectivity, for example with a system for continuous glucose monitoring, might help to further increase safety in the use of CSII in children. When selecting an insulin pump for a child, the features and characteristics of available pumps should be properly compared to ensure an effective and safe therapy. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Distribution of AAV-TK following intracranial convection-enhanced delivery into rats.
Cunningham, J; Oiwa, Y; Nagy, D; Podsakoff, G; Colosi, P; Bankiewicz, K S
2000-01-01
Adeno-associated virus (AAV)-based vectors are being tested in animal models as viable treatments for glioma and neurodegenerative disease and could potentially be employed to target a variety of central nervous system disorders. The relationship between dose of injected vector and its resulting distribution in brain tissue has not been previously reported nor has the most efficient method of delivery been determined. Here we report that convection-enhanced delivery (CED) of 2.5 x 10(8), 2.5 x 10(9), or 2.5 x 10(10) particles of AAV-thymidine kinase (AAV-TK) into rat brain revealed a clear dose response. In the high-dose group, a volume of 300 mm3 of brain tissue was partially transduced. Results showed that infusion pump and subcutaneous osmotic pumps were both capable of delivering vector via CED and that total particle number was the most important determining factor in obtaining efficient expression. Results further showed differences in histopathology between the delivery groups. While administration of vector using infusion pump had relatively benign effects, the use of osmotic pumps resulted in notable toxicity to the surrounding brain tissue. To determine tissue distribution of vector following intracranial delivery, PCR analysis was performed on tissues from rats that received high doses of AAV-TK. Three weeks following CED, vector could be detected in both hemispheres of the brain, spinal cord, spleen, and kidney.
Intra-arterial bromodeoxyuridine radiosensitization of malignant gliomas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hegarty, T.J.; Thornton, A.F.; Diaz, R.F.
1990-08-01
In the 1950's it was first observed that mammalian cells exposed to the halogenated deoxyuridines were more sensitive to ultraviolet light and radiation than untreated cells. This prompted early clinical trials with bromodeoxyuridine (BUdR) which showed mixed results. More recently, several Phase I studies, while establishing the feasibility of continuous intravenous (IV) infusion of BUdR, have reported significant dose limiting skin and bone marrow toxicities and have questioned the optimal method of BUdR delivery. To exploit the high mitotic activity of malignant gliomas relative to surrounding normal brain tissue, we have developed a permanently implantable infusion pump system for safe,more » continuous intraarterial (IA) internal carotid BUdR delivery. Since July 1985, 23 patients with malignant brain tumors (18 grade 4, 5 grade 3) have been treated in a Phase I clinical trial using IA BUdR (400-600 mg/m2/day X 8 1/2 weeks) and focal external beam radiotherapy (59.4 Gy at 1.8 Gy/day in 6 1/2 weeks). Following initial biopsy/surgery the infusion pump system was implanted; BUdR infusion began 2 weeks prior to and continued throughout the 6 1/2 week course of radiotherapy. There have been no vascular complications. Side-effects in all patients have included varying degrees of anorexia, fatigue, ipsilateral forehead dermatitis, blepharitis, and conjunctivitis. Myelosuppression requiring dose reduction occurred in one patient. An overall Kaplan-Meier estimated median survival of 20 months has been achieved. As in larger controlled series, histologic grade and age are prognostically significant. We have shown in a Phase I study that IA BUdR radiosensitization is safe, tolerable, may lead to improved survival, and appears to be an efficacious primary treatment of malignant gliomas.« less
Insulin Infusion Sets: A Critical Reappraisal.
Heinemann, Lutz
2016-05-01
An insulin infusion set (IIS) is a key component of insulin pumps. In daily practice issues with the IIS appear to be as relevant for a successful insulin therapy as the pumps themselves. The insulin is applied to the subcutaneous tissue via a Teflon(®) (Dupont, Wilmington, DE) or steel cannula. There are intensive discussions about the impact the choice of material for insulin application has on insulin pharmacokinetics. In this review, this factor and others that are known to have an impact on the successful usage of IIS are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Witte, C.; Kunth, M.; Rossella, F.
Xenon is well known to undergo host-guest interactions with proteins and synthetic molecules. As xenon can also be hyperpolarized by spin exchange optical pumping, allowing the investigation of highly dilute systems, it makes an ideal nuclear magnetic resonance probe for such host molecules. The utility of xenon as a probe can be further improved using Chemical Exchange Saturation Transfer using hyperpolarized nuclei (Hyper-CEST), but for highly accurate experiments requires a polarizer and xenon infusion system optimized for such measurements. We present the design of a hyperpolarizer and xenon infusion system specifically designed to meet the requirements of Hyper-CEST measurements. Onemore » key element of this design is preventing rubidium runaway, a chain reaction induced by laser heating that prevents efficient utilization of high photon densities. Using thermocouples positioned along the pumping cell we identify the sources of heating and conditions for rubidium runaway to occur. We then demonstrate the effectiveness of actively cooling the optical cell to prevent rubidium runaway in a compact setup. This results in a 2–3-fold higher polarization than without cooling, allowing us to achieve a polarization of 25% at continuous flow rates of 9 ml/min of {sup 129}Xe. The simplicity of this design also allows it to be retrofitted to many existing polarizers. Combined with a direction infusion system that reduces shot-to-shot noise down to 0.56% we have captured Hyper-CEST spectra in unprecedented detail, allowing us to completely resolve peaks separated by just 1.62 ppm. Due to its high polarization and excellent stability, our design allows the comparison of underlying theories of host-guest systems with experiment at low concentrations, something extremely difficult with previous polarizers.« less
Development of a simulated smart pump interface.
Elias, Beth L; Moss, Jacqueline A; Shih, Alan; Dillavou, Marcus
2014-01-01
Medical device user interfaces are increasingly complex, resulting in a need for evaluation in clinicallyaccurate settings. Simulation of these interfaces can allow for evaluation, training, and use for research without the risk of harming patients and with a significant cost reduction over using the actual medical devices. This pilot project was phase 1 of a study to define and evaluate a methodology for development of simulated medical device interface technology to be used for education, device development, and research. Digital video and audio recordings of interface interactions were analyzed to develop a model of a smart intravenous medication infusion pump user interface. This model was used to program a high-fidelity simulated smart intravenous medication infusion pump user interface on an inexpensive netbook platform.
Houghton, A K; Parsons, C G; Headley, P M
2001-04-01
The purpose of the present study was to investigate whether uncompetitive NMDA antagonists with fast channel blocking kinetics, which show fewer side effects in man than compounds such as ketamine, affect the development of tolerance to continuous exposure to morphine. Rats were trained on the Randall--Selitto apparatus before being implanted, under halothane anaesthesia, with primed mini-osmotic pumps (240 microl/day). Six rats were implanted with a vehicle filled pump, seven with a morphine filled pump (28.8 mg/kg/day), and eight with a pair of pumps, one containing morphine and the other Mrz 2/579, a new NMDA antagonist (40 mg/kg/day). A fourth group was implanted with a morphine filled pump followed 25 h later by a Mrz 2/579 filled pump. Paw withdrawal tests were undertaken immediately before, and at 2, 4, 6, 8, 10, 12, 24, 48 and 72 h after the first pump was implanted. Before pump implantation, withdrawal thresholds were 120+/-7 g (mean+/-SEM, n=30). Vehicle infusion had no effect on withdrawal thresholds, whereas morphine infusion increased them significantly at 2 and 4 h after pump implantation (+2 h: 208+/-14 g; P<0.001 vs. control). From 6 h the antinociception elicited by morphine declined progressively; at 10 h withdrawal thresholds were significantly lower than the 2 h post-treatment value (P<0.001). In rats treated with morphine plus Mrz 2/579, thresholds remained significantly higher between 10--72 h post-implantation than with morphine alone (P<0.05). In contrast, infusion of the same level of Mrz 2/579 once tolerance had developed did not reverse tolerance. These results indicate that fast NMDA channel blockers such as Mrz 2/579 may prove to be useful in enhancing analgesia to continuous morphine administration.
Burn Resuscitation Decision Support System (BRDSS)
2014-11-01
agreement was to package the software into a mobile device (the BRDSS-M, trade name Burn Navigator™) with substantial input from caregivers at the USAISR...combat casualties with >30% TBSA burns developed abdominal compartment syndrome (ACS) and perished.2 Between January 2006 and June 2007, after the...or even an open-loop system, could integrate the urine output monitor and infusion pump and free up the caregiver from manual data entry tasks to
Multiple Intravenous Infusions Phase 2b: Laboratory Study
Pinkney, Sonia; Fan, Mark; Chan, Katherine; Koczmara, Christine; Colvin, Christopher; Sasangohar, Farzan; Masino, Caterina; Easty, Anthony; Trbovich, Patricia
2014-01-01
Background Administering multiple intravenous (IV) infusions to a single patient via infusion pump occurs routinely in health care, but there has been little empirical research examining the risks associated with this practice or ways to mitigate those risks. Objectives To identify the risks associated with multiple IV infusions and assess the impact of interventions on nurses’ ability to safely administer them. Data Sources and Review Methods Forty nurses completed infusion-related tasks in a simulated adult intensive care unit, with and without interventions (i.e., repeated-measures design). Results Errors were observed in completing common tasks associated with the administration of multiple IV infusions, including the following (all values from baseline, which was current practice): setting up and programming multiple primary continuous IV infusions (e.g., 11.7% programming errors) identifying IV infusions (e.g., 7.7% line-tracing errors) managing dead volume (e.g., 96.0% flush rate errors following IV syringe dose administration) setting up a secondary intermittent IV infusion (e.g., 11.3% secondary clamp errors) administering an IV pump bolus (e.g., 11.5% programming errors) Of 10 interventions tested, 6 (1 practice, 3 technology, and 2 educational) significantly decreased or even eliminated errors compared to baseline. Limitations The simulation of an adult intensive care unit at 1 hospital limited the ability to generalize results. The study results were representative of nurses who received training in the interventions but had little experience using them. The longitudinal effects of the interventions were not studied. Conclusions Administering and managing multiple IV infusions is a complex and risk-prone activity. However, when a patient requires multiple IV infusions, targeted interventions can reduce identified risks. A combination of standardized practice, technology improvements, and targeted education is required. PMID:26316919
Multiple Intravenous Infusions Phase 2a: Ontario Survey
Fan, Mark; Koczmara, Christine; Masino, Caterina; Cassano-Piché, Andrea; Trbovich, Patricia; Easty, Anthony
2014-01-01
Background Research conducted in earlier phases of this study prospectively identified a number of concerns related to the safe administration of multiple intravenous (IV) infusions in Ontario hospitals. Objective To investigate the potential prevalence of practices or policies that may contribute to the patient safety risks identified in Phase 1b of this study. Data Sources and Review Methods Sixty-four survey responses were analyzed from clinical units where multiple IV infusions may occur (e.g., adult intensive care units). Survey questions were organized according to the topics identified in Phase 1b as potential contributors to patient harm (e.g., labelling practices, patient transfer practices, secondary infusion policies). Results Survey results indicated suboptimal practices and policies in some clinical units, and variability in a number of infusion practices. Key areas of concern included the following: use of primary IV tubing without back check valves when administering secondary infusions administration of secondary infusions with/as high-alert continuous IV medications potential confusion about how IV tubing should be labelled to reflect replacement date and time interruptions to IV therapy due to IV pump and/or tubing changes when patients are transferred between clinical units coadministration of continuous or intermittent infusions on central venous pressure monitoring ports variability in respondents’ awareness of the infusion pump's bolus capabilities Limitations Due to the limited sample size, survey responses may not be representative of infusion practices across Ontario. Answers to some questions indicated that the intent of the questions might have been misunderstood. Due to a design error, 1 question about bolus administration methods was not shown to as many respondents as appropriate. Conclusions The Ontario survey revealed variability in IV infusion practice across the province and potential opportunities to improve safety. PMID:26257837
[Effect of treatment of idiopathic hypogonadotropic hypogonadism with an LHRH infusion pump].
Goicolea Opacua, I; Cortázar Galarza, A; Cacho García, L; Guimón Bardesi, M; Vázquez García, J A
1989-01-01
Treatment of idiopathic hypogonadotropic hypogonadism with an intermittent LHRH infusion pump is more physiologic than the repeated injections of gonadotropin previously used. The results of treating 7 patients, 5 males and 2 females, with this new method are presented. A better FSH and LH response to the LHRH is achieved during treatment which results in a increase in testosterone production but not so of estradiol. The size of the testicles as well as the amount of pubic hair increased in all cases, although fertility was only achieved in one patient, who also showed the best testicular response. We may conclude that treatment with intermittent infusion of LHRH is an important innovation although only partially successful since there are resistant cases and the final outcome is not better than with other methods.
Maiguy-Foinard, Aurélie; Genay, Stéphanie; Lannoy, Damien; Barthélémy, Christine; Lebuffe, Gilles; Debaene, Bertrand; Odou, Pascal; Décaudin, Bertrand
2017-02-01
The aims are to identify critical parameters influencing the drug mass flow rate of infusion delivery to patients during multidrug infusion and to discuss their clinical relevance. A review of literature was conducted in January 2016 using Medline, Google Scholar, ScienceDirect, Web of Science and Scopus online databases. References relating to the accuracy of fluid delivery via gravity-flow intravenous (IV) infusion systems and positive displacement pumps, components of IV administration sets, causes of flow rate variability, potential complications due to flow rate variability, IV therapies especially at low flow rates and drug compatibilities were considered relevant. Several parameters impact the delivery of drugs and fluids by IV infusion. Among them are the components of infusion systems that particularly influence the flow rate of medications and fluids being delivered. By their conception, they may generate significant start-up delays and flow rate variability. Performing multidrug infusion requires taking into account two main points: the common dead volume of drugs delivered simultaneously with potential consequences on the accuracy and amount of drug delivery and the prevention of drug incompatibilities and their clinical effects. To prevent the potentially serious effects of flow rate variability on patients, clinicians should receive instruction on the fluid dynamics of an IV administration set and so be able to take steps to minimise flow rate changes during IV therapy. Copyright © 2016 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.
Bhattacharya, Sisir; Parekh, Satish; Dedhiya, Mahendra
2015-01-01
The objective of this study was to determine in-use stability of ceftaroline fosamil infusion solution of concentrations up to 12 mg/mL in elastomeric home infusion system prefilled with 0.9% Sodium Chloride Injection USP or 5% Dextrose Injection USP and MINI-BAG Plus Container delivery devices prefilled with 0.9% sodium chloride injection. In-use ceftaroline fosamil infusion solution (12 mg/mL) was prepared for elastomeric home infusion systems (Homepump Eclipse, Baxter Intermate, and AccuRx Elastomeric Pump) pre-filled with either 0.9% sodium chloride injection or 5% dextrose; or Baxter MINI-BAG Plus Containers pre-filled with 0.9% Sodium Chloride Injection USP (4 mg/mL to 12 mg/mL ceftaroline fosamil in final solution). The systems were stored refrigerated for 24 hours followed by up to 6 hours of storage at room temperature. Samples were analyzed at various time points for assay and degradation product by a validated stability-indicating high-performance liquid chromatography method. In-use ceftaroline fosamil infusion solution, ranging from 4-mg/mL to a maximum of 12-mg/mL concentration, in elastomeric home infusion systems prefilled with 0.9% sodium chloride injection or 5% dextrose, and MINI-BAG Plus Containers prefilled with 0.9% sodium chloride injection were chemically stable for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours at room temperature and had acceptable compatibility with material used. Ceftaroline fosamil (4 mg/mL to 12 mg/mL) maintains its potency for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours of storage at room temperature upon reconstitution in infusion solution with 0.9% sodium chloride or 5% dextrose when used in elastomeric home infusion system and MINI-BAG Plus Containers delivery devices prefilled with 0.9% sodium chloride injection.
Development of a standardized, citywide process for managing smart-pump drug libraries.
Walroth, Todd A; Smallwood, Shannon; Arthur, Karen; Vance, Betsy; Washington, Alana; Staublin, Therese; Haslar, Tammy; Reddan, Jennifer G; Fuller, James
2018-06-15
Development and implementation of an interprofessional consensus-driven process for review and optimization of smart-pump drug libraries and dosing limits are described. The Indianapolis Coalition for Patient Safety (ICPS), which represents 6 Indianapolis-area health systems, identified an opportunity to reduce clinically insignificant alerts that smart infusion pumps present to end users. Through a consensus-driven process, ICPS aimed to identify best practices to implement at individual hospitals in order to establish specific action items for smart-pump drug library optimization. A work group of pharmacists, nurses, and industrial engineers met to evaluate variability within and lack of scrutiny of smart-pump drug libraries. The work group used Lean Six Sigma methodologies to generate a list of key needs and barriers to be addressed in process standardization. The group reviewed targets for smart-pump drug library optimization, including dosing limits, types of alerts reviewed, policies, and safety best practices. The work group also analyzed existing processes at each site to develop a final consensus statement outlining a model process for reviewing alerts and managing smart-pump data. Analysis of the total number of alerts per device across ICPS-affiliated health systems over a 4-year period indicated a 50% decrease (from 7.2 to 3.6 alerts per device per month) after implementation of the model by ICPS member organizations. Through implementation of a standardized, consensus-driven process for smart-pump drug library optimization, ICPS member health systems reduced clinically insignificant smart-pump alerts. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Insulin Pump Malfunction During Hospitalization: Two Case Reports.
Faulds, Eileen R; Wyne, Kathleen L; Buschur, Elizabeth O; McDaniel, Jodi; Dungan, Kathleen
2016-06-01
Insulin pump malfunctions and failures continue to occur; however, more severe malfunctions such as the "runaway pump" phenomenon are rarely reported. This article describes two cases of pump malfunction in which pump users appear to have received an unsolicited bolus of insulin resulting in severe episodes of hypoglycemia during hospitalization. Both cases of insulin pump malfunction occurred in the inpatient setting at a large academic medical center in the United States. An analysis of the corresponding insulin pump downloads was performed. The Food and Drug Administration's (FDA's) Manufacturer and User Facility Device Experience (MAUDE) database was searched for similar cases involving Medtronic (Northridge, CA) insulin pumps using the terms "pump," "infusion," "insulin AND malfunction AND Medtronic." The two cases described show remarkable similarities, each demonstrating a severe hypoglycemic event preceded by an infusion site change followed by an alarm. In both cases a rapid spraying of insulin was reported. The insulin pump downloads validated much of the patients' and medical staff's descriptions of events. The FDA's MAUDE database search revealed 425 cases meeting our search term criteria. All cases were reviewed. Seven cases were identified involving independent movement of the reservoir piston. The cases detailed are the first to describe an insulin pump malfunction of this nature in the hospital setting involving unsolicited insulin boluses leading to severe hypoglycemia. The cases are particularly compelling in that they were witnessed by medical personnel. Providers and patients should receive instruction education on the recognition and management of insulin pump malfunction.
New technology, new errors: how to prime an upgrade of an insulin infusion pump.
Rule, Ann M; Drincic, Andjela; Galt, Kimberly A
2007-03-01
A series of use errors occurred when switching an ambulatory care clinic patient from an older model to a newer model of an ambulatory continuous subcutaneous insulin infusion pump. The nurse practitioner (N.P.) reviewed the new pump's mechanics with the patient, who had a 26-year history of Type 1 diabetes mellitus, and supervised the patient's programming of the pump. At bedtime, a blood sugar of > 250 mg/dL prompted the patient to give herself insulin via the pump. The next morning, she was treated at the emergency department for diabetic ketoacidosis. The pump had been improperly primed, resulting in no insulin delivery. The incident also reflected the absence of a fail-safe mechanism(s) on the pump to alert the user to the improper priming and inappropriate handoff of the patient's care. Unlike the old pump, the new pump did not require manual priming. The lack of delivery of insulin resulted in DKA, a potentially life-threatening complication of diabetes. A root cause analysis suggested several important safety issues, including skipping of steps on the patient training checklist and other shortcuts in patient training. The clinic developed policies and procedures, including mandatory formal training for each pump model by the certified pump trainer and for initiation of insulin pump therapy. This case illustrates the importance of a structured device selection process, provider education, patient education, and monitoring for safety and effectiveness of technological devices in care.
NASA Technical Reports Server (NTRS)
1987-01-01
Diabetics are no longer concerned with scheduling activities around peaking insulin levels since the use of an external pump from Pacesetter Systems, Inc. used to deliver insulin continuously at a preprogrammed individually adjusted rate. The pump wearer can lead a more normal existence, even participate in sports or travel, and there is an even greater benefit. Research indicates that infusion of "short acting" insulin in tiny amounts over a long period - instead of "long- acting" insulin has helped many diabetics achieve better control of blood sugar levels, thereby minimizing the possibility of complications and, in some cases, even halting the progression of complications.
Lee, Jong Hwa; Oh, Young Jun; Shim, Yon Hee; Hong, Yong Woo; Yi, Gijong
2006-01-01
This investigation evaluated the effect of continuous milrinone infusion on right ventriclular (RV) function during off-pump coronary artery bypass graft (OPCAB) surgery in patients with reduced RV function. Fifty patients scheduled for OPCAB, with thermodilution RV ejection fraction (RVEF) <35% after anesthesia induction, were randomly allocated to either milrinone (0.5 µg/kg/min) or control (saline) group. Hemodynamic variables and RV volumetric data measured by thermodilution method were collected as follows: after anesthesia induction (T1); 10 min after heart displacement for obtuse marginal artery anastomosis (T2); after pericardial closure (T3). Cardiac index and heart rate increased and systemic vascular resistance significantly decreased in milrinone group at T2. Initially lower RVEF of milrinone group was eventually comparable to control group after milrinone infusion. RVEF did not significantly change at T2 and T3 in both groups. RV end-diastolic volume in milrinone group consistently decreased from the baseline at T2 and T3. Continuous infusion of milrinone without a bolus demonstrated potentially beneficial effect on cardiac output and RV afterload in patients with reduced RV function during OPCAB. However, aggressive augmentation of intravascular volume seems to be necessary to maximize the effect of the milrinone in these patients. PMID:17043419
Klumpner, Thomas T; Lange, Elizabeth M S; Ahmed, Heena S; Fitzgerald, Paul C; Wong, Cynthia A; Toledo, Paloma
2016-11-01
Programmed intermittent bolus injection of epidural anesthetic solution results in decreased anesthetic consumption and better patient satisfaction compared with continuous infusion, presumably by better spread of the anesthetic solution in the epidural space. It is not known whether the delivery speed of the bolus injection influences analgesia outcomes. The objective of this in vitro study was to determine the pressure generated by a programmed intermittent bolus pump at 4 infusion delivery speeds through open-ended, single-orifice and closed-end, multiorifice epidural catheters. In vitro observational study. Not applicable. Not applicable. A CADD-Solis Pain Management System v3.0 with Programmed Intermittent Bolus Model 2110 was connected via a 3-way adapter to an epidural catheter and a digital pressure transducer. Pressures generated by delivery speeds of 100, 175, 300, and 400 mL/h of saline solution were tested with 4 epidural catheters (2 single orifice and 2 multiorifice). These runs were replicated on 5 pumps. Analysis of variance was used to compare the mean peak pressures of each delivery speed within each catheter group (single orifice and multiorifice). Thirty runs at each delivery speed were performed with each type of catheter for a total of 240 experimental runs. Peak pressure increased with increasing delivery speeds in both catheter groups (P<.001). Peak pressures were higher with the multiorifice catheter compared with the single-orifice catheter at all delivery speeds (P<.001, for all). Using a pump designed for programmed intermittent infusion boluses, the delivery speed of saline solution through epidural catheters was directly related to the peak pressures. Future work should evaluate whether differences in the delivery speed of anesthetic solution into the epidural space correlate with differences in the duration and quality of analgesia during programmed intermittent epidural bolus delivery. Copyright © 2016 Elsevier Inc. All rights reserved.
Faes, Katrien; Lahoutte, Tony; Hoorens, Anne; Tournaye, Herman; Goossens, Ellen
2017-03-01
When fertility is impaired by anticancer treatment, spermatogonial stem cell transplantation (SSCT) could be used as a fertility restoration technique later on in life. Previously, we have demonstrated that a testicular cell suspension could be injected into a human cadaver testis, however, leakage to the interstitium was observed. In this study, injection of mouse testicular cells at an injection height of 50 cm (hydrostatic pressure) or via an automated injection pump (1400 µl, 2600 µl and 3000 µl) was evaluated. Significant difference in the filled radioactive volume was reached between the group in which 1400 µl was injected with an infusion pump and the groups in which 2600 µl (P = 0.019) or 3000 µl (P = 0.010) was injected. In all experimental groups green fluorescent protein positive (GFP + ) cells were observed in the seminiferous tubules. In conclusion, a lower injection height did not resolve the leakage of the injected cells to the interstitium. Using the infusion pump resulted in more efficient filling of the seminiferous tubules with lower interexperimental variability. Although leakage to the interstitium was still observed, with further optimisation, the use of an infusion pump for clinical application is advantageous. Copyright © 2016 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.
Risk factors for baclofen pump infection in children: a multivariate analysis.
Spader, Heather S; Bollo, Robert J; Bowers, Christian A; Riva-Cambrin, Jay
2016-06-01
OBJECTIVE Intrathecal baclofen infusion systems to manage severe spasticity and dystonia are associated with higher infection rates in children than in adults. Factors unique to this population, such as poor nutrition and physical limitations for pump placement, have been hypothesized as the reasons for this disparity. The authors assessed potential risk factors for infection in a multivariate analysis. METHODS Patients who underwent implantation of a programmable pump and intrathecal catheter for baclofen infusion at a single center between January 1, 2000, and March 1, 2012, were identified in this retrospective cohort study. The primary end point was infection. Potential risk factors investigated included preoperative (i.e., demographics, body mass index [BMI], gastrostomy tube, tracheostomy, previous spinal fusion), intraoperative (i.e., surgeon, antibiotics, pump size, catheter location), and postoperative (i.e., wound dehiscence, CSF leak, and number of revisions) factors. Univariate analysis was performed, and a multivariate logistic regression model was created to identify independent risk factors for infection. RESULTS A total of 254 patients were evaluated. The overall infection rate was 9.8%. Univariate analysis identified young age, shorter height, lower weight, dehiscence, CSF leak, and number of revisions within 6 months of pump placement as significantly associated with infection. Multivariate analysis identified young age, dehiscence, and number of revisions as independent risk factors for infection. CONCLUSIONS Young age, wound dehiscence, and number of revisions were independent risk factors for infection in this pediatric cohort. A low BMI and the presence of either a gastrostomy or tracheostomy were not associated with infection and may not be contraindications for this procedure.
Continuous subcutaneous infusion of morphine in children with cancer.
Miser, A W; Davis, D M; Hughes, C S; Mulne, A F; Miser, J S
1983-04-01
Seventeen children with severe pain due to malignant neoplasm were successfully treated with a subcutaneous infusion of morphine sulfate using a syringe pump. Pain relief was adequate in every case without major side effects. The median dosage required was 0.06 mg/kg/hr (range, 0.025 to 1.79 mg/kg/hr). Three patients received the subcutaneous infusion at home. No patient required an intravenous line for pain control.
Pratt, Brenda E.; Chittenden, Sarah J.; Murray, Iain S.; Causer, Louise; Grey, Matthew J.; Gear, Jonathan I.; Du, Yong; Flux, Glenn D.
2017-01-01
The administration of radionuclide therapies presents significant radiation protection challenges. The aim of this work was to develop a delivery system for intravenous radioisotope therapies to substantially moderate radiation exposures to staff and operators. A novel device (InfuShield) was designed and tested before being used clinically. The device consists of a shielded enclosure which contains the therapeutic activity and, through the hydraulic action of back-to-back syringes, allows the activity to be administered using a syringe pump external to the enclosure. This enables full access to the pump controls while simultaneously reducing dose to the operator. The system is suitable for use with all commercially available syringe pumps and does not require specific consumables, maximising both the flexibility and economy of the system. Dose rate measurements showed that at key stages in an 131I mIBG treatment procedure, InfuShield can reduce dose to operators by several orders of magnitude. Tests using typical syringes and infusion speeds show no significant alteration in administered flow rates (maximum of 1.2%). The InfuShield system provides a simple, safe and low cost method of radioisotope administration. PMID:28187040
Chang, Mun Young; Rah, Yoon Chan; Choi, Jun Jae; Woo, Shin Wook; Hwang, Yu-Jung; Eastwood, Hayden; O'Leary, Stephen J; Lee, Jun Ho
2017-08-01
When administered perioperatively, systemic dexamethasone will reduce the hearing loss associated with cochlear implantation (CI) performed via the round window approach. The benefits of electroacoustic stimulation have led to interest in pharmacological interventions to preserve hearing after CI. Thirty guinea pigs were randomly divided into three experimental groups: a control group; a 3-day infusion group; and a 7-day infusion group. Dexamethasone was delivered via a mini-osmotic pump for either 3 or 7 days after CI via the round window. Pure tone-evoked auditory brainstem response (ABR) thresholds were monitored for a period of 12 weeks after CI. The cochleae were then collected for histology. At 4 and 12 weeks after CI, ABR threshold shifts were significantly reduced in both 7-day and 3-day infusion groups compared with the control group. Furthermore, the 7-day infusion group has significantly reduced ABR threshold shifts compared with the 3-day infusion group. The total tissue response, including fibrosis and ossification, was significantly reduced in the 7-day infusion group compared with the control group. On multiple regression the extent of fibrosis predicted hearing loss across most frequencies, while hair cell counts predicted ABR thresholds at 32 kHz. Hearing protection after systemic administration of steroids is more effective when continued for at least a week after CI. Similarly, this treatment approach was more effective in reducing the fibrosis that encapsulates the CI electrode. Reduced fibrosis seemed to be the most likely explanation for the hearing protection.
Smiths Medical Medfusion 3010a syringe pump may overinfuse if software is outdated.
2010-04-01
Smiths Medical Medfusion 3010a syringe pumps that aren't equipped with the latest software version (2.0.6) could overinfuse if the "recall last settings" function is used following an infusion in volume/time mode. If your facility has pumps equipped with software versions older than 2.0.6, contact Smiths Medical to obtain an upgrade.
INTRARENAL GHRELIN RECEPTOR INHIBITION AMELIORATES ANGIOTENSIN II-DEPENDENT HYPERTENSION IN RATS.
Kemp, Brandon A; Howell, Nancy L; Padia, Shetal H
2018-06-20
The intrarenal ghrelin receptor (GR) is localized to collecting duct (CD) cells where it increases αENaC-dependent sodium reabsorption in rodents. We hypothesized that chronic GR inhibition with intrarenal GR siRNA lowers blood pressure (BP) in Angiotensin II-dependent hypertension via reductions in αENaC-dependent sodium reabsorption. Uninephrectomized Sprague-Dawley rats (N=121) received subcutaneous osmotic pumps for chronic systemic delivery of Angiotensin II or vehicle (5% dextrose in water). Rats also received intrarenal infusion of vehicle, GR siRNA, or scrambled (SCR) siRNA. In rats receiving intrarenal vehicle or intrarenal SCR siRNA, systemic Angiotensin II infusion increased sodium retention and BP on day 1, and BP remained elevated throughout the 5-day study. These rats also demonstrated increased CD GR expression after 5 days of infusion. However, intrarenal GR siRNA infusion prevented Angiotensin II-mediated sodium retention on day 1, induced a continuously negative cumulative sodium balance compared with Angiotensin II alone, and reduced BP chronically. Glomerular filtration rate and renal blood flow remained unchanged in GR siRNA-infused rats. Systemic Angiotensin II infusion also increased serum aldosterone levels, CD αENaC and pSGK1 expression in rats with intrarenal SCR siRNA; however these effects were not observed in the presence of intrarenal GR siRNA, despite exposure to the same systemic Angiotensin II. These data demonstrate that chronic inhibition of intrarenal GR activity significantly reduces αENaC -dependent sodium retention, resulting in a negative cumulative sodium balance, thereby ameliorating Angiotensin II-induced hypertension in rats. Renal GRs represent a novel therapeutic target for the treatment of hypertension and other sodium-retaining states.
[Automated anesthesia record system].
Zhu, Tao; Liu, Jin
2005-12-01
Based on Client/Server architecture, a software of automated anesthesia record system running under Windows operation system and networks has been developed and programmed with Microsoft Visual C++ 6.0, Visual Basic 6.0 and SQL Server. The system can deal with patient's information throughout the anesthesia. It can collect and integrate the data from several kinds of medical equipment such as monitor, infusion pump and anesthesia machine automatically and real-time. After that, the system presents the anesthesia sheets automatically. The record system makes the anesthesia record more accurate and integral and can raise the anesthesiologist's working efficiency.
Berman, Mitchell F; Iyer, Nikhil; Freudzon, Leon; Wang, Shuang; Freundlich, Robert E; Housey, Michelle; Kheterpal, Sachin
2017-10-01
Continuous medication infusions are commonly used during surgical procedures. Alarm settings for infusion pumps are considered important for patient safety, but limits are not created in a standardized manner from actual usage data. We estimated 90th and 95th percentile infusion rates from a national database for potential use as upper limit alarm settings. We extracted infusion rate data from 17 major hospitals using intraoperative records provided by Multicenter Perioperative Outcomes Group for adult surgery between 2008 and 2014. Seven infusions were selected for study: propofol, remifentanil, dexmedetomidine, norepinephrine, phenylephrine, nitroglycerin, and esmolol. Each dosage entry for an infusion during a procedure was included. We estimated the 50th, 90th, and 95th percentile levels for each infusion across institutions, and performed quantile regression to examine factors that might affect the percentiles rates, such as use in general anesthesia versus sedation. The median 90th and 95th percentile infusion rates (with interquartile range) for propofol were 150 (140-150) and 170 (150-200) μg/kg/min. Quantile regression demonstrated higher 90th and 95th percentile rates during sedation for gastrointestinal endoscopy than for all surgical procedures performed under general anesthesia. For selected vasoactive medications, the corresponding median 90th and 95th percentile rates (with interquartile range) were norepinephrine 14.0 (9.8-18.1) and 18.3 (12.6-23.9) μg/min, and phenylephrine 60 (55-80) and 80 (75-100) μg/min. Alarm settings based on infusion rate percentile limits would be triggered at predictable rates; ie, the 95th percentile would be exceeded and an alarm sounded during 1 in 20 infusion rate entries. As a result, institutions could establish pump alarm settings consistent with desired alarm frequency using their own or externally validated usage data. Further study will be needed to determine the optimal percentile for infusion alarm settings.
1990-12-01
Volumetric Infusion Pump is conditionally acceptable for use. The Air -In- Line detector does not sense air bubbles 0.95 cm (3/8 inch) or smaller...been fitted with an improved brushless air circulation motor, Brailsford model T- 2NFR. Using the new motor, the 185 passed EMI and is acceptable for...USAF School of Aerospace Medicine, Human Systems Division, Air Force Systems Command, Brooks Air Force Base, Texas, under job order 7930-16- 12. This
Rocuronium: automatic infusion versus manual administration with TOF monitorisation.
Ozturk Arikan, Fatma Gulcin; Turan, Guldem; Ozgultekin, Asu; Sivrikaya, Zubeyir; Cosar, Bekir Cem; Onder, Dondu Nisa
2016-10-01
TOF (train-of-four) monitoring provides objective data in application of neuromuscular blocking agent. Thus, applicator-based differences are eliminated and optimum muscle relaxation is maintained during operation. In the present study, we aimed to compare the effects of target-controlled infusion system and standard TOF monitoring, on use of rocuronium. ASA I-II patients, who were aged between 18 and 75 years and scheduled for elective abdominal surgery at Haydarpaşa Numune Training and Research Hospital, were enrolled in the study. In order to evaluate neuromuscular blockade, the patients in Group 1 were connected to the acceleromyography device of the target-controlled infusion pump (Veryark-CLMRIS-I-China) while the ones in Group 2 were connected to the routinely used acceleromyography device (TOF Watch SX). There was no significant difference between groups regarding patient characteristics, the durations of anaesthesia and surgery, quality of intubation, time to extubation and time to recovery (TOF ratio of 0.9). Intubation time was significantly longer in Group 1 (Automated group) as compared to Group 2 (Control group) (p < 0.05). The total rocuronium amount used in Group 1 was found to be significantly higher than the amount used in Group 2 (p < 0.05). There was no clinical evidence of residual neuromuscular blockage or reoccurrence of neuromuscular blockage in any patient in either group. Both methods can be used for administration of neuromuscular blocker agent during moderate time anesthesia. No advantage was noted when rocuronium was administered via automatical infusion pump during anaesthesia.
A Parylene MEMS Electrothermal Valve
Li, Po-Ying; Givrad, Tina K.; Holschneider, Daniel P.; Maarek, Jean-Michel I.; Meng, Ellis
2011-01-01
The first microelectromechanical-system normally closed electrothermal valve constructed using Parylene C is described, which enables both low power (in milliwatts) and rapid operation (in milliseconds). This low-power valve is well suited for applications in wirelessly controlled implantable drug-delivery systems. The simple design was analyzed using both theory and modeling and then characterized in benchtop experiments. Operation in air (constant current) and water (current ramping) was demonstrated. Valve-opening powers of 22 mW in air and 33 mW in water were obtained. Following integration of the valve with catheters, our valve was applied in a wirelessly operated microbolus infusion pump, and the in vivo functionality for the appropriateness of use of this pump for future brain mapping applications in small animals was demonstrated. PMID:21350679
Safety and efficacy of gas-forced infusion (air pump) in coaxial phacoemulsification.
Chaudhry, Prashaant; Prakash, Gaurav; Jacob, Soosan; Narasimhan, Smita; Agarwal, Sunita; Agarwal, Amar
2010-12-01
To evaluate the safety and efficacy of gas-forced infusion (air pump) in uncomplicated coaxial phacoemulsification. Dr. Agarwal's Eye Hospital, Chennai, India. Comparative case series. Specular microscopy and optical coherence tomography were used to analyze the endothelium, central macular thickness (CMT), and peripapillary retinal nerve fiber layer (RNFL) thickness before and approximately 1, 7, 30, and 90 days after coaxial phacoemulsification with (infusion group) or without (control group) gas-forced infusion. Surgical time, surge, phaco energy, irrigation fluid volume, surgical ease, complications, and visual gain in the 2 groups were compared. The mean endothelial cell loss was lower in the infusion group than in the control group (6.98% ± 8.46% [SD] versus 10.54% ± 11.24%; P = .045) and the irrigation/aspiration time significantly shorter (54 ± 39 seconds versus 105 ± 84 seconds; P = .0001). The surgery was rated as easier with gas-forced infusion (scale 1 to 10: mean 8.3 ± 2.1 versus 6.6 ± 1.6; P = .00002). However, the amount of irrigating fluid volume was higher in the infusion group (117 ± 37 mL versus 94 ± 41 mL; P = .003). No surge occurred in the infusion group; it occurred a mean of 3.00 ± 4.16 times in the control group (P<.0001). The rate of visual gain, CMT, peripapillary RNFL thickness, phaco time, and amount of phaco energy were comparable in the 2 groups. Gas-forced infusion was safe and effective in controlling surge and increased the safety, ease, and speed of coaxial phacoemulsification. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Mphahlele, Noko R; Fuller, Andrea; Roth, Joachim; Kamerman, Peter R
2004-10-01
Most experimentally induced fevers are acute, usually lasting approximately 6-12 h, and thus do not mimic chronic natural fevers, which can extend over several days or more. To produce a model of chronic natural fever, we infused eight goats (Capra hircus) intravenously with 2 ml of 2 x 10(11) cell walls of Staphylococcus aureus (S. aureus) for 6 days using osmotic infusion pumps (10 microl/h) while measuring changes in body temperature, behavior, and plasma cortisol concentration. Seven control animals were infused with sterile saline. Abdominal temperature-sensitive data loggers and osmotic infusion pumps were implanted under halothane anesthesia. To compare our new model with existing models of experimental fever, we also administered 2-ml bolus intravenous injections of 2 x 10(11) S. aureus cell walls, 0.1 microg/kg lipopolysaccharide (Escherichia coli, serotype 0111:B4), and sterile saline in random order to six other goats. Bolus injection of lipopolysaccharide and S. aureus induced typical acute phase responses, characterized by fevers lasting approximately 6 h, sickness behavior, and increased plasma cortisol concentration. Infusion of S. aureus evoked prolonged fevers, which lasted for approximately 3 days, starting on day 4 of infusion (ANOVA, P < 0.05), and did not disrupt the normal circadian rhythm of body temperature. However, pyrogen infusion did not cause plasma cortisol concentration to rise (ANOVA, P > 0.05) or the expression of sickness behavior. In conclusion, infusion of S. aureus produced a fever response resembling that of sustained natural fevers but did not elicit the cortisol and behavioral responses that often are described clinically and during short-term experimental fevers.
Insulin pump treatment in children and adolescents with type 1 diabetes.
Hofer, S; Meraner, D; Koehle, J
2012-08-01
Within children and adolescents with type 1 diabetes insulin pump treatment is of increasing interest. Frequency of insulin pump therapy shows a rapid and steep increase in toddlers and young children. Insulin pumps allow a close to physiologic insulin delivery due to basal rates programmed over 24 hours with circadian rhythms taken into account. Furthermore, another advantage of technical devices as insulin pumps is the application of extremely small amounts of insulin, as needed in very young children, with the possibility of titration of infusion rates down to 0.01E/h. Dawn Phenomenon and hypoglycemic events are main indications for insulin pump treatment in children and adolescents. A significant reduction of severe hypoglycemia, especially nocturnal hypoglycemia was shown, whereas a reduction of HbA1c and an improvement of metabolic control has been reported in short term and in some but not all long term studies. Ketoacidosis rate did not increase in insulin pump therapy. Complications due to continuous subcutaneous insulin infusion, like local infections and dermatological changes are frequent but were not associated with glycemic control and did not lead to discontinuation of insulin pump treatment. Pump discontinuation rate in general is low, varying from 1% in very young children up to 6% in pubertal adolescent girls. Insulin pump treatment was shown to be safe and efficient and the simplicity of handling the devices as well as an improvement of quality of life may explain the rapid increase of pump treatment in young children and adolescents with type 1 diabetes.
Fault Detection and Safety in Closed-Loop Artificial Pancreas Systems
2014-01-01
Continuous subcutaneous insulin infusion pumps and continuous glucose monitors enable individuals with type 1 diabetes to achieve tighter blood glucose control and are critical components in a closed-loop artificial pancreas. Insulin infusion sets can fail and continuous glucose monitor sensor signals can suffer from a variety of anomalies, including signal dropout and pressure-induced sensor attenuations. In addition to hardware-based failures, software and human-induced errors can cause safety-related problems. Techniques for fault detection, safety analyses, and remote monitoring techniques that have been applied in other industries and applications, such as chemical process plants and commercial aircraft, are discussed and placed in the context of a closed-loop artificial pancreas. PMID:25049365
Zhang, YanPing; Kawedia, Jitesh D; Myers, Alan L; McIntyre, Chelsey M; Anderson, Peter M; Kramer, Mark A; Culotta, Kirk S
2014-02-01
Ifosfamide plus mesna have been used recently in a high-dose regimen that allows this chemotherapy to be given to outpatients with less toxicity over 14 days using a portable pump. However, there is a need for published stability information. The aim of this study was to investigate the physicochemical stability of ifosfamide with mesna in normal saline at room temperature over a prolonged period of 14 days. Infusion solutions of 1:1 ifosfamide and mesna at final concentrations of 10, 20 and 30 mg/mL were prepared with 0.9% sodium chloride in PVC bags. Solutions were stored at room temperature. Concentrations of ifosfamide and mesna were measured at 0 and 1, 3, 7 and 14 days using a stability-indicating reversed phase high-performance liquid chromatography (HPLC) assay with ultraviolet detection. Ifosfamide and mesna were both physicochemically stable (>94%) for 14 days in all tested infusion solutions (10, 20 and 30 mg/mL). Our stability data indicate that ifosfamide and mesna (1:1) combination can be administered as a prolonged continuous infusion with portable pump in an outpatient setting without replacement of the infusion bag. We suggest 20 mg/mL as a reasonable concentration for infusion rates of about 2-4 cc/hr over prolonged periods of time.
Recent progress in developing durable and permanent impeller pump.
Qian, K X; Zeng, P; Ru, W M; Yuan, H Y
2002-04-01
Since 1980s, the author's impeller pump has successively achieved the device implantability, blood compatibility and flow pulsatility. In order to realize a performance durability, the author has concentrated in past years on solving the bearing problems of the impeller pump. Recent progress has been obtained in developing durable and permanent impeller blood pumps. At first, a durable impeller pump with rolling bearing and purge system has been developed, in which the wear-less rollers made of super-high-molecular weight polythene make the pump to work for years without mechanical wear; and the purge system enables the bearing to work in saline and heparin, and no thrombus therefore could be formed. Secondly, a durable centrifugal pump with rolling bearing and axially reciprocating impeller has been developed, the axial reciprocation of rotating impeller makes the fresh blood in and out of the bearing and to wash the rollers once a circle; in such way, no thrombus could be formed and no fluid infusion is necessary, which may bring inconvenience and discomfort to the receptors. Finally, a permanent maglev impeller pump has been developed, its rotor is suspended and floating in the blood under the action of permanent magnetic force and nonmagnetic forces, without need for position measurement and feed-back control. In conclusion, an implantable, pulsatile, and blood compatible impeller pump with durability may have more extensive applications than ever before and could replace the donor heart for transplantation in the future.
Kim, Tae Sik; Sun, Kyung; Lee, Kyu Baek; Lee, Hye Won; Baek, Kwang Je; Park, Sung Young; Son, Ho Sung; Kim, Kwang Taik; Kim, Hyoung Mook
2004-12-01
Nonpulsatile blood pumps are mainly used in extracorporeal life support systems. Although pulsating blood flow is known to be physiological, a pulsatile pump is not commonly applied in a circuit with a membrane oxygenator because of damage to the blood cells. The hypothesis that the placement of a pressure-relieving compliance chamber in a circuit might reduce blood cell trauma was tested. An extracorporeal life support circuit was constructed in an acute lung injury model of dogs by oleic acid infusion. The animals were divided into three groups. In group I (n = 6) a nonpulsatile centrifugal pump was used as a control. In group II (n = 4) a single-pulsatile pump was used, and in group III (n = 6) a single-pulsatile pump equipped with a compliance chamber was used. Pump flow was maintained at 1.8-2.0 L/min for 2 h. Hemodynamics and blood gas analyses indicated that the pulsatile groups II and III had better results than the nonpulsatile group I. The plasma-free hemoglobin level, which indicates blood cell trauma, was the lowest in group I and the highest in group II but was significantly decreased in group III. A pressure-relieving compliance chamber could significantly reduce high circuit pressures and blood cell trauma.
Oyama, Hirofumi; Kito, Akira; Maki, Hideki; Hattori, Kenichi; Tanahashi, Kuniaki
2010-01-01
Two patients with subarachnoid hemorrhage recovered consciousness after intrathecal baclofen administration using an implanted intrathecal baclofen pump delivering 50 microg per day using a simple infusion mode. Intrathecal baclofen resulted in significant reduction of spasticity 3 months after the implantation. Case 1 was reduced to a completely bedridden state with spasticity and could slightly move her fingers following commands. However, the patient could eat food and wash her face with minimal assistance at 3 months after the implantation, and could stand up in the parallel bars with assistance and speak several words at 8 months. Case 2 was in a completely bedridden state at 10 months after onset and could neither drink water nor follow instructions. However, the patient became oriented and could eat by herself within 3 to 4 weeks of implantation. She could walk with a cane and use the stairs with minimal assistance at 2 and 3 months after implantation. The patient could speak fluently within 6 months of implantation. Flatulence and dysuria happened during the screening test, but these symptoms were not repeated after implantation of a pump-catheter-system and continuous intrathecal baclofen infusion. Continuous intrathecal baclofen infusion caused both improvement in muscle tone and spasms and consciousness recovery from the vegetative state. This therapy is a strong candidate treatment for patients with spasticity and consciousness disturbance.
Robert, Julien; Sorrieul, Jérémy; Rossignol, Elsa; Beaussart, Hélène; Kieffer, Hélène; Folliard, Caroline; Dupoiron, Denis; Devys, Catherine
2017-01-01
Pain is the most feared symptom amongst individuals living with cancer. In 15% to 20% of patients, conventional analgesic therapy either fails to relieve pain or induces adverse effects. Intrathecal drug delivery systems may present an effective alternative for pain management. The Cancerology Center Paul Papin protocol includes an admixture of morphine, ropivacaine, and ziconotide in intrathecal preparations. These drugs are administered by a fully implantable or an external pump. Syringes or polyolefin infusion bags are prepared for refill just before use. Few centers in France use the method of intrathecal analgesia. Therefore, for those patients receiving intrathecal preparations, each filling requires that the patients be transported from their local hospital (or their home) to a referral center where the patients are monitored. They sometimes must travel up to a hundred kilometers to have a pump filled. The preparation and the analytical control of the mixture are carried out only by those centers meeting the proper criteria, which includes the proper equipment. To spare the patient this travel, a peripheral center may be subcontracted to manage the patient's pump refill. No data are available concerning the chemical stability of admixtures in syringes or polyolefin infusion bags. The aim of this study was to evaluate, with a new analytical method using ultra high-performance liquid chromatography, the chemical stability of these admixtures in syringes or in polyolefin infusion bags. Ziconotide 1 µg/mL was combined with ropivacaine (7.5 mg/mL) and morphine (3.5 mg/mL) in syringes at 5°C, 21°C, and 31°C, and in polyolefin infusion bags at 21°C. Assays were performed using ultra high-pressure liquid chromatography. In syringes stored at 21°C and 31°C, concentrations after 6 hours were not in the acceptable criterion of 10% variability. When syringes were stored at 5°C, the residual concentration of ziconotide after 3 days was 100.5% +/- 2.6% [92.7% to 108.4%]. In polyolefin infusion bags, the residual concentration of ziconotide after 14 days was 96.9% +/- 2.2% [90.1% to 103.6%]. This study demonstrates the chemical stability of this admixture in syringes stored at 5°C for 3 days and in polyolefin plastibags stored at 21°C for 14 days. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Randomized Trial of Infusion Set Function: Steel Versus Teflon
Patel, Parul J.; Benasi, Kari; Ferrari, Gina; Evans, Mark G.; Shanmugham, Satya; Wilson, Darrell M.
2014-01-01
Abstract Background: This study compared infusion set function for up to 1 week using either a Teflon® (Dupont™, Wilmington, DE) catheter or a steel catheter for insulin pump therapy in type 1 diabetes mellitus. Subjects and Methods: Twenty subjects participating in a randomized, open-labeled, crossover study were asked to wear two Quick-Set® and two Sure-T® infusion sets (both from Medtronic Minimed, Northridge, CA) until the infusion set failed or was worn for 1 week. All subjects wore a MiniMed continuous glucose monitoring system for the duration of the study. Results: One subject withdrew from the study. There were 38 weeks of Sure-T wear and 39 weeks of Quick-Set wear with no difference in the survival curves of the infusion sets. There was, however, a 15% initial failure rate with the Teflon infusion set. After 7 days, both types of infusion sets had a 64% failure rate. Overall, 30% failed because of hyperglycemia and a failed correction dose, 13% were removed for pain, 10% were pulled out by accident, 10% had erythema and/or induration of>10 mm, 5% fell out because of loss of adhesion, and 4% were removed for infection. The main predictor of length of wear was the individual subject. There was no increase in hyperglycemia or daily insulin requirements when an infusion set was successfully used for 7 days (n=25 of 77 weeks). Conclusions: We found no difference between steel and Teflon infusion sets in their function over 7 days, although 15% of Teflon sets failed because of kinking on insertion. The strongest predictor of prolonged 7-day infusion set function was the individual subject, not the type of infusion set. PMID:24090124
Ferreira Laso, Lourdes; López Picado, Amanda; Antoñanzas Villar, Fernando; Lamata de la Orden, Laura; Ceballos Garcia, Mar; Ibañez López, Carolina; Pipaon Ruilope, Lorena; Lamata Hernandez, Felix; Valero Martinez, Cesar; Aizpuru, Felipe; Hernandez Chaves, Roberto
2015-09-01
Effective treatment of postoperative pain contributes to decreasing the rate of complications as well as the total cost of the operated patients. The aim of this study was to analyze the costs and the efficiency of use of continuous infusion of levobupivacaine 0.5 % with the help of an infusion pump in modified radical mastectomy. A cost calculation of the analgesic procedures (continuous infusion of levobupivacaine 0.5 % [levobupivacaine group (LG)] or saline [saline group (SG)] (2 ml/h 48 h) has been carried out based on the data of a previous clinical trial (double-blind randomized study) of patients who underwent modified radical mastectomy surgery. The measure of the effectiveness was the point reduction of pain derived from the verbal numeric rating scale (VNRS). The usual incremental cost-effectiveness ratio (ICER) was performed. Considering only the intravenous analgesia, overall costs were lower in LG, as less analgesia was used (EUR14.06 ± 7.89 vs. 27.47 ± 14.79; p < 0.001). In this study the costs of the infusion pump were not calculated as it was used by both groups and they offset each other. However, if the infusion pump costs were included, costs would be higher in the LG, (EUR91.89 ± 7.89 vs. 27.47 ± 14.79; p < 0.001) and then the ICER was -8.51, meaning that for every extra point of decrease in the pain verbal numerical rating score over the 2-day period, the cost increased by EUR8.51. Infiltration of local anesthetics is an effective technique for controlling postoperative pain and the associated added costs are relatively low in relation to the total cost of mastectomy, therefore providing patients with a higher quality of care in the prevention of pain. clinicaltrials.gov: reference number NCT01389934. http://clinicaltrials.gov/show/NCT01389934
Giri, Priya; Ebert, Sabine; Braumann, Ulf-Dietrich; Kremer, Mathias; Giri, Shibashish; Machens, Hans-Günther; Bader, Augustinus
2015-01-01
Large doses of recombinant growth factors formulated in solution form directly injected into the body is usual clinical practice in treating second-degree scald injuries, with promising results, but this approach creates side effects; furthermore, it may not allow appropriate levels of the factor to be sensed by the target injured tissue/organ in the specific time frame, owing to complications arising from regeneration. In this research, two delivery methods (infusion pumping and local topical application) were applied to deliver recombinant human erythropoietin (rHuEPO) for skin regeneration. First, rHuEPO was given in deep second-degree scald injury sites in mice by infusion pump. Vascularization was remarkably higher in the rHuEPO pumping group than in controls. Second, local topical application of rHuEPO gel was given in deep second-degree scald injury sites in rats. Histological analysis showed that epithelialization rate was significantly higher in the rHuEPO gel-treated group than in controls. Immunohistochemical studies showed that the rHuEPO gel-treated group showed remarkably higher expression of skin regeneration makers than the control group. An accurate method for visualization and quantification of blood vessel networks in target areas has still not been developed up to this point, because of technical difficulties in detecting such thin blood vessels. A method which utilizes a series of steps to enhance the image, removes noise from image background, and tracks the vessels edges for vessel segmentation and quantification has been used in this study. Using image analysis methods, we were able to detect the microvascular networks of newly formed blood vessels (less than 500 μm thickness), which participate in the healing process, providing not only nutrition and oxygen to grow tissues but also necessary growth factors to grow tissue cells for complete skin regeneration. The rHuEPO-treated group showed higher expression of stem cell markers (CD 31, CD 90, CD 71, and nestin), which actively contribute to in-wound-healing processes for new hair follicle generation as well as skin regeneration. Collectively, both rHuEPO group pumping into the systemic circulation system, and injection into the local injury area, prompted mice and rats to form new blood vessel networks in scald injury sites, which significantly participate in the scald healing process. These results may lead to the development of novel treatments for scald wounds.
Giri, Priya; Ebert, Sabine; Braumann, Ulf-Dietrich; Kremer, Mathias; Giri, Shibashish; Machens, Hans-Günther; Bader, Augustinus
2015-01-01
Large doses of recombinant growth factors formulated in solution form directly injected into the body is usual clinical practice in treating second-degree scald injuries, with promising results, but this approach creates side effects; furthermore, it may not allow appropriate levels of the factor to be sensed by the target injured tissue/organ in the specific time frame, owing to complications arising from regeneration. In this research, two delivery methods (infusion pumping and local topical application) were applied to deliver recombinant human erythropoietin (rHuEPO) for skin regeneration. First, rHuEPO was given in deep second-degree scald injury sites in mice by infusion pump. Vascularization was remarkably higher in the rHuEPO pumping group than in controls. Second, local topical application of rHuEPO gel was given in deep second-degree scald injury sites in rats. Histological analysis showed that epithelialization rate was significantly higher in the rHuEPO gel-treated group than in controls. Immunohistochemical studies showed that the rHuEPO gel-treated group showed remarkably higher expression of skin regeneration makers than the control group. An accurate method for visualization and quantification of blood vessel networks in target areas has still not been developed up to this point, because of technical difficulties in detecting such thin blood vessels. A method which utilizes a series of steps to enhance the image, removes noise from image background, and tracks the vessels edges for vessel segmentation and quantification has been used in this study. Using image analysis methods, we were able to detect the microvascular networks of newly formed blood vessels (less than 500 μm thickness), which participate in the healing process, providing not only nutrition and oxygen to grow tissues but also necessary growth factors to grow tissue cells for complete skin regeneration. The rHuEPO-treated group showed higher expression of stem cell markers (CD 31, CD 90, CD 71, and nestin), which actively contribute to in-wound-healing processes for new hair follicle generation as well as skin regeneration. Collectively, both rHuEPO group pumping into the systemic circulation system, and injection into the local injury area, prompted mice and rats to form new blood vessel networks in scald injury sites, which significantly participate in the scald healing process. These results may lead to the development of novel treatments for scald wounds. PMID:26005333
Bicket, Mark C; Hanna, George M
2016-02-01
Intrathecal drug delivery systems represent an increasingly common treatment modality for patients with a variety of conditions, including chronic pain and spasticity. Pumps rely on electronic programming to properly control and administer highly concentrated medications. Electromagnetic interference (EMI) is a known exposure that may cause a potential patient safety issue stemming from direct patient injury, pump damage, or changes to pump operation or flow rate. The objective of our case report was to describe an approach to evaluating a patient with a pump prior to and following exposure to EMI from electroconvulsive therapy (ECT), as well as to document findings from device interrogations associated with this event. Case report. Academic university-based pain management center. We present the case of a patient with an intrathecal pump who underwent multiple exposures to EMI in the form of 42 ECT sessions. Interrogation of the intrathecal drug delivery system revealed no safety issues following ECT sessions. At no time were error messages, unintentional changes in event logs, unintentional changes in pump settings, or evidence of pump stall or over-infusion noted. Communication with multiple entities (patient, family, consulting physicians, and device manufacturer) and maintaining vigilance through device interrogation both before and after EMI exposure are appropriate safeguards to mitigate the risk and detect potential adverse events of EMI with intrathecal drug delivery systems. Given the infrequent reports of device exposure to ECT, best practices may be derived from experience with EMI exposure from magnetic resonance imaging (MRI). Although routine EMI exposure to intrathecal drug delivery systems should be avoided, we describe one patient with repeated exposure to ECT without apparent complication.
1997-01-01
Successful implementation of CSII requires a motivated patient with a range of technical skills and self-management capabilities. Patients develop this expertise through an ongoing program of education and the support that a healthcare team knowledgeable in insulin pump therapy can provide.
Potential Therapeutic Use of Relaxin in Healing Cranial Bone Defects
2017-09-01
to measure circulating concentrations of relaxin during the infusion by ELISA ; 3. sacrifice the mice at 10-12 days after cranial defect; 4. fix the...osmotic pump for 10-12 days, and to measure circulating concentrations of relaxin during the infusion by ELISA . Values of 0.35, 0.69, 1.61, 0.66, 1.99...vehicle-infused mice, because in our previous work, none was detected. This makes sense, because the ELISA we use does not detect mouse relaxin
Bleyenheuft, C; Filipetti, P; Caldas, C; Lejeune, T
2007-01-01
To evaluate effectiveness and safety of intrathecal baclofen administration (ITB) testing with continuous infusion via an external pump before the implantation of an internal one in ambulatory spastic patients with cerebral palsy (CP). Seven CP patients (3 diplegic, 4 quadriplegic - 18.4+/-7.0 years) with a progressive decrease in walking ability were included. Assessments included: Ashworth's scale, Observational Gait Scale (OGS), and GMFM-66. During the ITB test (45-150 microg/24h), spasticity decreased by more than two points on Ashworth's scale (p<0.001) and walking ability improved (median OGS increased from 7 to 9, p
Chemical Stability of Telavancin in Elastomeric Pumps.
Sand, Patrick; Aladeen, Traci; Kirkegaard, Paul; LaChance, Dennis; Slover, Christine
2015-12-01
VIBATIV is a once-daily, injectable lipoglycopeptide antibiotic approved in the U.S. for the treatment of hospital-acquired and ventilator-associated bacterial pneumonia (HABP/VABP) caused by susceptible isolates of Staphylococcus aureus when alternative treatments are not suitable. In addition, VIBATIV is approved in the U.S. for the treatment of adult patients with complicated skin & skin structure infections (cSSSI) caused by susceptible isolates of Gram-positive bacteria, including Staphylococcus aureus, both methicillin-susceptible (MSSA) and methicillin-resistant (MRSA) strains. To evaluate the chemical stability of telavancin (Vibativ; Theravance Biopharma US, Inc, Northbrook, Illinois), a lipoglycopeptide antibiotic with activity against methicillin-resistant Staphylococcus aureus, in 2 types of elastomeric pumps, the Intermate Infusion System (Baxter International Inc) and the Homepump Eclipse (I-Flow Corporation). Different sizes of the Baxter (Ontario, Canada) (105 mL and 275 mL) and I-Flow (Stoughton, Massachusetts) (100 mL and 250 mL) pumps were compared with glass controls. The telavancin drug product was reconstituted and diluted to concentrations of 0.6 mg/mL and 8.0 mg/mL using either 0.9% saline, 5% dextrose in water, or sterilized water for injection (0.6 mg/mL telavancin) or saline (8.0 mg/mL telavancin) followed by Ringer's Lactate solution. Pumps were filled and stored at 2°C to 8°C, protected from light. Aliquots from both pump types and for all telavancin reconstitution/dilution schemes and concentrations were taken over a period of 8 days and analyzed for appearance, pH, telavancin concentration and purity, and degradation products. The pH of all pump solutions remained consistent throughout the 8-day analysis period, within a range of 4.6 to 5.7 for the 0.6 mg/mL and 4.4 to 4.9 for the 8.0 mg/mL telavancin solutions. There was no significant change in the chromatographic purity for any of the pump solutions examined. All decreases in telavancin concentration were ≤2.7%. Comparison of each test sample solution to the corresponding glass control indicated no loss of active drug due to absorption by the elastomeric material of the pumps. The greatest increase in the amount of total degradants observed over the 8-day period was ~0.7 w/w%. The results of this study indicate that telavancin remains chemically stable when diluted in the Intermate Infusion System and the Homepump Eclipse elastomeric pumps and stored at 2°C to 8°C for up to 8 days protected from light at the concentration range and dilution schemes evaluated.
NASA Technical Reports Server (NTRS)
Lloyd, Charles W.
1993-01-01
The Space Station Freedom (SSF) Health Maintenance Facility (HMF) will provide medical care for crew members for up to 10 days. An integral part of the required medical care consists of providing intravenous infusion of fluids, electrolyte solutions, and nutrients to sustain an ill or injured crew member. In terrestrial health care facilities, intravenous solutions are normally stored in large quantities. However, due to the station's weight and volume constraints, an adequate supply of the required solutions cannot be carried onboard SSF. By formulating medical fluids onboard from concentrates and station water as needed, the Fluid Therapy System (FTS) eliminates weight and volume concerns regarding intravenous fluids. The first full-system demonstration of FTS is continuous microgravity will be conducted in Spacelab-Japan (SL-J). The FTS evaluation consists of two functional objectives and an in-flight demonstration of intravenous administration of fluids. The first is to make and store sterile water and IV solutions onboard the spacecraft. If intravenous fluids are to be produced in SSF, successful sterilization of water and reconstituting of IV solutions must be achieved. The second objective is to repeat the verification of the FTS infusion pump, which had been performed in Spacelab Life Sciences - 1 (SLS-1). during SLS-1, the FTS IV pump was operated in continuous microgravity for the first time. The pump functioned successfully, and valuable knowledge on its performance in continuous microgravity was obtained. Finally, the technique of starting an IF in microgravity will be demonstrated. The IV technique requires modifications in microgravity, such as use of restraints for equipment and crew members involved.
Hawley, Philippa; Beddard-Huber, Elizabeth; Grose, Cameron; McDonald, William; Lobb, Daphne; Malysh, Louise
2009-01-01
BACKGROUND: The need for intrathecal infusion in a palliative care setting is infrequent. Despite established efficacy, safety and cost effectiveness, this is considered an ‘extraordinary measure’ in Canada. Patients requiring this approach are not typical palliative care patients, having shorter and more uncertain life expectancies. OBJECTIVES: The present study is a qualitative exploration of the impact of intrathecal pump implantation on cancer patients, and also the impact of the intervention on the staff caring for those patients. METHODS: Palliative care unit patients who received an implanted intrathecal pump or dome catheter for intractable cancer pain participated in multiple semistructured interviews. Doctors and nurses caring for each patient were also interviewed. Interviews were recorded and analyzed for themes. The study terminated when saturation was reached. RESULTS: Six patients participated, with up to three interviews each. Twenty-four staff interviews took place. Patients’ hopes and expectations were not always fully met, but the infusions had a profound positive effect on quality of life. Patients expressed anxiety about dependence on the device, and also on a few highly skilled individuals. Staff interviews revealed a significant impact on the ‘culture’ of the palliative care unit. Clear communication of the rationale for infusion was very important, as was regular education about infusion management. CONCLUSIONS: Implanted intrathecal infusion devices are a necessary part of a tertiary level cancer pain management service for the unfortunate minority with intractable pain. Practical recommendations for care are made for palliative care programs contemplating offering intrathecal infusions. PMID:19862372
Heinemann, Lutz
2009-11-01
Bolus infusion of insulin along with a meal is a standard procedure with continuous subcutaneous insulin infusion. Modern insulin pumps allow applying this bolus in four different ways: infusion of the total dose at once or splitting the dose into two boluses, infusion of a part of the bolus in the usual manner plus infusion of the other part over a prolonged period of time (with a higher infusion rate than the basal rate), or infusion of the total dose in the form of an elevated basal rate. Depending on the composition of the given meal and its glycemic index, this is an attempt to match the circulating insulin levels to the rate of glucose absorption from the gut in order to minimize postprandial glycemic excursions. However, in the framework of evidence-based medicine, the benefits of this approach should be proven in appropriately designed clinical studies. Performance of meal-related studies requires careful attention to many aspects in order to allow meaningful evaluation of a given intervention (i.e., type of bolus). Critical evaluation of the clinical experimental studies and the one clinical study published about the impact of different types of boluses on postprandial metabolic control revealed fundamental shortcomings in study design and performance in these studies. Insufficient establishment of comparable preprandial glycemia and insulinemia on the different study days within and between the patients studied is one key aspect. Therefore, the recommendation made in most of these studies (i.e., use of dual-wave bolus) has to be accepted with care, until we have better evidence.
NASA Technical Reports Server (NTRS)
Dobnig, H.; Turner, R. T.
1997-01-01
PTH treatment can result in dramatic increases in cancellous bone volume in normal and osteopenic rats. However, this potentially beneficial response is only observed after pulsatile treatment; continuous infusion of PTH leads to hypercalcemia and bone abnormalities. The purpose of these studies was to determine the optimal duration of the PTH pulses. A preliminary study revealed that human PTH-(1-34) (hPTH) is cleared from circulation within 6 h after sc administration of an anabolic dose of the hormone (80 microg/kg). To establish the effects of gradually extending the duration of exposure to hPTH without increasing the daily dose, we programmed implanted Alzet osmotic pumps to deliver the 80 microg/kg x day dose of the hormone during pulses of 1, 2, and 6 h/day, or 40 microg/kg x day continuously. Discontinuous infusion was accomplished by alternate spacing of external tubing with hPTH solution and sesame oil. After 6 days of treatment, we evaluated serum chemistry and bone histomorphometry. As negative and positive controls, groups of rats received pumps that delivered vehicle only and 80 microg/kg x day hPTH by daily sc injection, respectively. Dynamic and static bone histomorphometry revealed that the daily sc injection and 1 h/day infusion dramatically increased osteoblast number and bone formation in the proximal tibial metaphysis, whereas longer infusion resulted in systemic side-effects, including up to a 10% loss in body weight, hypercalcemia, and histological changes in the proximal tibia resembling abnormalities observed in patients with chronic primary hyperparathyroidism, including peritrabecular marrow fibrosis and focal bone resorption. Infusion for as little as 2 h/day resulted in minor weight loss and changes in bone histology that were intermediate between sc and continuous administration. The results demonstrate that the therapeutic interval for hPTH exposure is brief, but that programmed administration of implanted hormone is a feasible alternative to daily injection as a route for administration of the hormone.
Maurizi, Anna R; Suraci, Concetta; Pitocco, Dario; Schiaffini, Riccardo; Tubili, Claudio; Morviducci, Lelio; Giordano, Renato; Manfrini, Silvia; Lauro, Davide; Frontoni, Simona; Pozzilli, Paolo; Buzzetti, Raffaella
2016-01-01
This document has been developed by a group of Italian diabetologists with extensive experience in continuous subcutaneous insulin infusion (CSII) therapy to provide indications for the clinical management of CSII in diabetic patients (both type 1 and type 2) based on delivery mode operating in Italy. Although the potential benefits of pump therapy in achieving glycemic goals is now accepted, such results cannot be obtained without specific knowledge and skills being conveyed to patients during ad hoc educational training. To ensure that these new technologies reach their full effectiveness, as demonstrated theoretically and clinically, a careful assessment of the overall therapeutic and educational process is required, in both qualitative and quantitative terms. Therefore, to ensure the cost-effectiveness of insulin pump therapy and to justify reimbursement of therapy costs by the National Health System in Italy, in this article we present a model for diabetes and healthcare centers to follow that provides for different levels of expertise in the field of CSII therapy. This model will guarantee the provision of excellent care during insulin pump therapies, thus representing the basis for a successful outcome and expansion of this form of insulin treatment in patients with diabetes while also keeping costs under control. © 2015 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.
Evaluating the use of the Cleo 90 infusion set for patients on a palliative care unit.
Schneider, Michael; Hoffmann, Martin; Lorenzl, Stefan
2009-08-01
Although the use of subcutaneous infusion is common in palliative care, problems can occur. Normally, butterfly needles are used; however, there are occasional issues with patients being able to walk around or with restless patients who suffer from delirium. In these cases, needles often dislocate; therefore, a small observational study was undertaken to evaluate the use of the Cleo 90 infusion set. The use of this needle system has been well established in diabetic patients who require continuous subcutaneous infusion of insulin, but has never been tested in a wider range of patients with other medications. In this 6-month study, 45 patients were identified for subcutaneous infusion and a total of 112 needles were used for this study, since we initially changed each site after 2 days to control the local site for adverse reactions. We have not observed any complications with drug combinations delivered via the attached tube and the needle, and have used up to five different drugs mixed together in a single syringe. Needles could be used for a mean time of 5 +/- 2 days (range 2-12 days). Local site reactions have been observed only with sodium chloride infusions, which were not delivered via a pump system. Reddening and induration of the skin occurred, but they were reversible after removing the needle. As this was a small study in only one unit, without standardization the results can only be observational. However, it has shown, for the first time, that the Cleo 90 needle can be safe and comfortable.
Cour, M; Hernu, R; Bénet, T; Robert, J M; Regad, D; Chabert, B; Malatray, A; Conrozier, S; Serra, P; Lassaigne, M; Vanhems, P; Argaud, L
2013-11-01
Manual changeover of vasoactive drug infusion pumps (CVIP) frequently lead to haemodynamic instability. Some of the newest smart pumps allow automated CVIP. The aim of this study was to compare automated CVIP with manual 'Quick Change' relays. We performed a prospective, quasi-experimental study, in a university-affiliated intensive care unit (ICU). All adult patients receiving continuous i.v. infusion of vasoactive drugs were included. CVIP were successively performed manually (Phase 1) and automatically (Phase 2) during two 6-month periods. The primary endpoint was the frequency of haemodynamic incidents related to the relays, which were defined as variations of mean arterial pressure >15 mm Hg or heart rate >15 bpm. The secondary endpoints were the nursing time dedicated to relays and the number of interruptions in care because of CVIP. A multivariate mixed effects logistic regression was fitted for analytic analysis. We studied 1329 relays (Phase 1: 681, Phase 2: 648) from 133 patients (Phase 1: 63, Phase 2: 70). Incidents related to CVIP decreased from 137 (20%) in Phase 1 to 73 (11%) in Phase 2 (P<0.001). Automated relays were independently associated with a 49% risk reduction of CVIP-induced incidents (adjusted OR=0.51, 95% confidence interval 0.34-0.77, P=0.001). Time dedicated to the relays and the number of interruptions in care to manage CVIP were also significantly reduced with automated relays vs manual relays (P=0.001). These results demonstrate the benefits of automated CVIP using smart pumps in limiting the frequency of haemodynamic incidents related to relays and in reducing the nursing workload.
NASA Technical Reports Server (NTRS)
Dankanich, John W.; Walker, Mitchell; Swiatek, Michael W.; Yim, John T.
2013-01-01
The electric propulsion community has been implored to establish and implement a set of universally applicable test standards during the research, development, and qualification of electric propulsion systems. Variability between facility-to-facility and more importantly ground-to-flight performance can result in large margins in application or aversion to mission infusion. Performance measurements and life testing under appropriate conditions can be costly and lengthy. Measurement practices must be consistent, accurate, and repeatable. Additionally, the measurements must be universally transportable across facilities throughout the development, qualification, spacecraft integration, and on-orbit performance. A recommended practice for making pressure measurements, pressure diagnostics, and calculating effective pumping speeds with justification is presented.
Terry, Victoria R; Terry, Peter C; Moloney, Clint; Bowtell, Les
2018-02-01
There is growing evidence that online resources used to develop clinical skills among students in the healthcare professions can produce equivalent learning outcomes to traditional face-to-face training methods. Whether clinical competence is retained equally well for online and face-to-face training methods is not yet established. The objective of the study was to compare retention of competence in using an IV infusion pump among nursing students trained in its use using three different protocols. A quasi-experimental design was used. The study was conducted in the School of Nursing and Midwifery at a regional university in Queensland, Australia. Participants were 102 first year nursing students (female=89, male=13) enrolled in a medications course, ranging in age from 18 to 44years. Three groups of participants were trained in the use of an IV infusion pump and competence was assessed following a 26-week period of no access to the pump. Group 1 participants (ONL; n=34) were trained online using an Intravenous Pump Emulator (IVPE); Group 2 participants (ONC; n=38) were trained on campus using an actual IV pump in a traditional face-to-face setting; Group 3 participants (ONL+ONC; n=30) were trained both on campus using the actual IV pump and online using the IVPE. As hypothesised, no significant differences in learning outcomes, measured by assessment scores out of 80 points, were found between the ONL (M=68.7±5.9) and ONC (M=65.5±11.5; p>0.05) groups. The ONL+ONC group recorded the highest mean assessment score (M=70.0±5.0) and completed the assessment task significantly faster (p<0.001) than the other two groups. This study suggests that nursing students retained clinical competence in preparing and administrating IV infusions better when face-to-face and online learning were combined. Copyright © 2017 Elsevier Ltd. All rights reserved.
Real-Time Detection of Infusion Site Failures in a Closed-Loop Artificial Pancreas.
Howsmon, Daniel P; Baysal, Nihat; Buckingham, Bruce A; Forlenza, Gregory P; Ly, Trang T; Maahs, David M; Marcal, Tatiana; Towers, Lindsey; Mauritzen, Eric; Deshpande, Sunil; Huyett, Lauren M; Pinsker, Jordan E; Gondhalekar, Ravi; Doyle, Francis J; Dassau, Eyal; Hahn, Juergen; Bequette, B Wayne
2018-05-01
As evidence emerges that artificial pancreas systems improve clinical outcomes for patients with type 1 diabetes, the burden of this disease will hopefully begin to be alleviated for many patients and caregivers. However, reliance on automated insulin delivery potentially means patients will be slower to act when devices stop functioning appropriately. One such scenario involves an insulin infusion site failure, where the insulin that is recorded as delivered fails to affect the patient's glucose as expected. Alerting patients to these events in real time would potentially reduce hyperglycemia and ketosis associated with infusion site failures. An infusion site failure detection algorithm was deployed in a randomized crossover study with artificial pancreas and sensor-augmented pump arms in an outpatient setting. Each arm lasted two weeks. Nineteen participants wore infusion sets for up to 7 days. Clinicians contacted patients to confirm infusion site failures detected by the algorithm and instructed on set replacement if failure was confirmed. In real time and under zone model predictive control, the infusion site failure detection algorithm achieved a sensitivity of 88.0% (n = 25) while issuing only 0.22 false positives per day, compared with a sensitivity of 73.3% (n = 15) and 0.27 false positives per day in the SAP arm (as indicated by retrospective analysis). No association between intervention strategy and duration of infusion sets was observed ( P = .58). As patient burden is reduced by each generation of advanced diabetes technology, fault detection algorithms will help ensure that patients are alerted when they need to manually intervene. Clinical Trial Identifier: www.clinicaltrials.gov,NCT02773875.
The CareFlight Stretcher Bridge: a compact mobile intensive care unit.
Wishaw, K J; Munford, B J; Roby, H P
1990-05-01
A mobile intensive care module has been developed for aeromedical transport of the critical care patient. It incorporates monitoring, ventilator, oxygen and suction, and infusion pumps. The device clips to a lightweight stretcher, over the patient at hip to knee level. This system is compatible with nearly all patient transport vehicles and allows monitors to be run from vehicle power. An assessment of the system after more than 500 transports is that it represents a significant advance over systems used previously. The advantages and disadvantages of the system compared with unmounted or vehicle-mounted equipment are discussed.
Management of diabetes mellitus: is the pump mightier than the pen?
Pickup, John C
2012-02-28
Continuous subcutaneous insulin infusion (CSII, or insulin pump therapy) reduces HbA1c levels and hypoglycaemia in patients with type 1 diabetes mellitus (T1DM) compared with multiple daily insulin injections (MDI). The greatest reduction in HbA(1c) levels with CSII occurs in patients with the worst glycaemic control; therefore, the most appropriate and cost-effective use of CSII in adults with T1DM is in those who have continued, elevated HbA(1c) levels or disabling hypoglycaemic episodes with MDI (including the use of long-acting insulin analogues and structured patient education). The disadvantages of CSII include higher costs than MDI and the risk of ketosis in the event of pump failure. In children with T1DM, CSII may be used when MDI is considered impractical or inappropriate. Pumps are not generally recommended for patients with type 2 diabetes mellitus but may improve control in some subgroups. A new generation of smaller insulin infusion pumps with an integrated cannula, called patch pumps, could improve uptake of CSII in general. The important clinical question is not whether CSII is more efficacious than MDI in general adult T1DM, but whether CSII further improves glycaemic control when this control continues to be poor with MDI, and evidence exists that in most cases it does.
Renard, Eric
2008-07-01
Insulin delivery is a crucial component of a closed-loop system aiming at the development of an artificial pancreas. The intravenous route, which has been used in the bedside artificial pancreas model for 30 years, has clear advantages in terms of pharmacokinetics and pharmacodynamics, but cannot be used in any ambulatory system so far. Subcutaneous (SC) insulin infusion benefits from the broad expansion of insulin pump therapy that promoted the availability of constantly improving technology and fast-acting insulin analog use. However, persistent delays of insulin absorption and action, variability and shortterm stability of insulin infusion from SC-inserted catheters generate effectiveness and safety issues in view of an ambulatory, automated, glucose-controlled, artificial beta cell. Intraperitoneal insulin delivery, although still marginally used in diabetes care, may offer an interesting alternative because of its more-physiological plasma insulin profiles and sustained stability and reliability of insulin delivery.
Implantable batteryless device for on-demand and pulsatile insulin administration
NASA Astrophysics Data System (ADS)
Lee, Seung Ho; Lee, Young Bin; Kim, Byung Hwi; Lee, Cheol; Cho, Young Min; Kim, Se-Na; Park, Chun Gwon; Cho, Yong-Chan; Choy, Young Bin
2017-04-01
Many implantable systems have been designed for long-term, pulsatile delivery of insulin, but the lifetime of these devices is limited by the need for battery replacement and consequent replacement surgery. Here we propose a batteryless, fully implantable insulin pump that can be actuated by a magnetic field. The pump is prepared by simple-assembly of magnets and constituent units and comprises a drug reservoir and actuator equipped with a plunger and barrel, each assembled with a magnet. The plunger moves to noninvasively infuse insulin only when a magnetic field is applied on the exterior surface of the body. Here we show that the dose is easily controlled by varying the number of magnet applications. Also, pump implantation in diabetic rats results in profiles of insulin concentration and decreased blood glucose levels similar to those observed in rats treated with conventional subcutaneous insulin injections.
Blandford, Ann; Furniss, Dominic; Lyons, Imogen; Chumbley, Gill; Iacovides, Ioanna; Wei, Li; Cox, Anna; Mayer, Astrid; Schnock, Kumiko; Bates, David Westfall; Dykes, Patricia C; Bell, Helen; Franklin, Bryony Dean
2016-03-03
Intravenous medication is essential for many hospital inpatients. However, providing intravenous therapy is complex and errors are common. 'Smart pumps' incorporating dose error reduction software have been widely advocated to reduce error. However, little is known about their effect on patient safety, how they are used or their likely impact. This study will explore the landscape of intravenous medication infusion practices and errors in English hospitals and how smart pumps may relate to the prevalence of medication administration errors. This is a mixed-methods study involving an observational quantitative point prevalence study to determine the frequency and types of errors that occur in the infusion of intravenous medication, and qualitative interviews with hospital staff to better understand infusion practices and the contexts in which errors occur. The study will involve 5 clinical areas (critical care, general medicine, general surgery, paediatrics and oncology), across 14 purposively sampled acute hospitals and 2 paediatric hospitals to cover a range of intravenous infusion practices. Data collectors will compare each infusion running at the time of data collection against the patient's medication orders to identify any discrepancies. The potential clinical importance of errors will be assessed. Quantitative data will be analysed descriptively; interviews will be analysed using thematic analysis. Ethical approval has been obtained from an NHS Research Ethics Committee (14/SC/0290); local approvals will be sought from each participating organisation. Findings will be published in peer-reviewed journals and presented at conferences for academic and health professional audiences. Results will also be fed back to participating organisations to inform local policy, training and procurement. Aggregated findings will inform the debate on costs and benefits of the NHS investing in smart pump technology, and what other changes may need to be made to ensure effectiveness of such an investment. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Jacob, Soosan; Narasimhan, Smita; Agarwal, Amar; Agarwal, Athiya; A I, Saijimol
2017-08-01
To assess an air pump-assisted technique for graft centration, graft edge unfolding, and graft uncreasing while performing pre-Descemet endothelial keratoplasty (PDEK) using young donor grafts. Continuous pressurized air infusion was used for graft centration, graft edge unfolding, and graft unwrinkling. Ten eyes of 10 patients underwent PDEK with donors aged below 40 years. In all eyes, the donor scrolled into tight scrolls. In all cases, the air pump-assisted technique was effective in positioning and centering the graft accurately and in straightening infolded graft edges and smoothing out graft creases and wrinkles. Endothelial cell loss was 38.6%. Postoperative best-corrected visual acuity at 6 months was 0.66 ± 0.25 in decimal equivalent. Continuous pressurized air infusion acted as a third hand providing a continuous pressure head that supported the graft and prevented graft dislocation as well as anterior chamber collapse during intraocular maneuvering. Adequate maneuvering space was available in all cases, and bleeding, if any, was tamponaded successfully in all cases. Although very young donor grafts may be used for PDEK, they are difficult to center and unroll completely before floating against host stroma. An air pump-assisted technique using continuous pressurized air infusion allows successful final graft positioning even with very young donor corneas. It thus makes surgery easier as several key steps are made easier to handle. It additionally helps in tamponading hemorrhage during peripheral iridectomy, increasing surgical space, preventing fluctuations in the anterior chamber depth, and promoting graft adherence.
van Hoef, M E; Zonnenberg, B A; de Graeff, A; van Milligen de Wit, A W; Tjia, P; Neijt, J P
1991-03-30
A study to evaluate the feasibility and toxicity of outpatient continuous intravenous infusion of fluorouracil (5-FU) was initiated at the department of Medical Oncology of the University Hospital of Utrecht. To this purpose a subcutaneous drug delivery system (Port-a-Cath) was implanted in 36 patients with various advanced cancers. Of these patients 83% had received prior chemotherapy (including 5-FU in 62%). Ambulatory continuous-infusion pumps were used to administer 5-FU in a dosage of 300 mg/m2/24 h. The treatment was continued until tumour progression was seen, and it was interrupted in case of toxicity grade 2 or more (WHO criteria). A Port-a-Cath was implanted 37 times in the 36 patients. The main complications of this infusion system were pneumothorax (2/37), arrhythmia (1/37), catheter sepsis (2/37) and thrombosis (2/37); they were easily managed. The toxicity and feasibility of this treatment were evaluable in 30 patients. They received a median of 44 g 5-FU (range 11-136, 5 g, mean 281 mg/m2/24 h) during a median infusion time of 12 weeks (range 4-32 w). Side effects were encountered in 70% of the patients and consisted of the hand-foot syndrome (14/30), nausea and vomiting (8/30), diarrhoea (8/30) and stomatitis (7/30). The toxicity was completely reversible after a short interruption of the chemotherapy. The treatment was tolerated well, and good palliation was attained in 22 of 30 patients. The best response was seen in patients with colon and breast cancer. We conclude that continuous infusion of 5-FU is a reliable outpatient chemotherapy even in this category of patients.
Basal forebrain infusion of HC-3 in rats: maze learning deficits and neuropathology.
Hurlbut, B J; Lubar, J F; Switzer, R; Dougherty, J; Eisenstadt, M L
1987-01-01
Ten adult male Sprague-Dawley rats were infused with hemicholinium (HC-3) using mini-osmotic pumps over a 14 day period through bilateral, chronically implanted cannulae in the nucleus basalis magnocellularis (nbm). Ten matched controls were infused in the same fashion with saline. HC-3 rats receiving implants demonstrated a significant deficit in maze-learning ability compared with individual and group performances before receiving the implants. In saline rats there was no significant difference in maze-learning ability before and after receiving implants. The HC-3 group receiving implants demonstrated a significant deficit in maze-learning ability compared with the saline control group. Serial sections through nbm from control and HC-3 rats indicated that all cannulae were located within infusion range of nbm. In HC-3 subjects, cholinergic cell bodies were destroyed with concurrent degeneration of terminal fields in cortex. Except for cannula insertion damage, the cholinergic neurotransmitter system appeared unharmed in controls. Stains for neuritic plaques and neurofibrillary damage were negative in both groups. The memory deficit in experimental subjects supported by the demonstrated destruction of nbm cholinergic neurons suggests that HC-3 may be useful in the development of an animal model for Alzheimer's Disease.
Kerr, David; Hoogma, Roel P.L.M; Buhr, Andreas; Petersen, Bettina; Storms, Fred E.M.G
2010-01-01
Background The aim of this study was to evaluate a newly developed system for insulin delivery incorporating a multifunctional blood glucose meter and a remotely controlled insulin pump (ACCU-CHEK® Combo system) in established pump users with type 1 diabetes. The technology was assessed both from device performance and subject usability perspectives. Method A multicenter, prospective, single group study was carried out in five centers in the Netherlands and four centers in the United Kingdom for more than 6 months. The study was divided into two phases: Phase 1 (4 weeks) for device validation purposes and phase 2 (22 weeks) to observe the impact of the system on metabolic control, patient satisfaction [using the Diabetes Treatment Satisfaction Questionnaire (DTSQ)] and device safety. Results Eighty subjects completed the planned study period. There were no unexpected device errors. Treatment satisfaction was high at baseline and further increased to study end (DTSQ change version: sum score, 10.6 ± 7.2; scale score range, -18 to +18, p < 0.0001). Hemoglobin A1c improved continuously over time, from 7.9% (±0.9%) to 7.7% (±0.8%) at month 3 (p < 0.001) and 7.6% (±0.8%) at month 6 (p < 0.0001). The frequency of severe hypoglycemia was 0.08 per patient years. There was no case of ketoacidosis. Conclusions The new system was evaluated by experienced continuous subcutaneous insulin infusion users as safe in daily practice and associated with favorable treatment satisfaction and a modest improvement in glycemic control. PMID:21129336
Baclofen Pumps: Uses and Complications.
Woolf, Seth M; Baum, Carl R
2017-04-01
Intrathecal baclofen therapy, given via an implanted pump in the abdominal wall either as a continuous infusion or bolus dosing, has been used for more than 25 years to treat the spasticity and dystonia associated with various brain and spinal cord conditions. Pediatric clinicians occasionally encounter baclofen pumps, and in the pediatric setting, significant morbidity can arise from their use. This article presents the background, mechanism of action, uses, and complications of intrathecal baclofen therapy and discusses various management strategies should complications occur.
Wilson, Ana Maria Miranda Martins; Peterlini, Maria Angélica Sorgini; Pedreira, Mavilde da Luz Gonçalves
2016-08-15
to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells) and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies. identificar na literatura a produção científica acerca dos efeitos de bomba de infusão na administração de hemácias e avaliar as implicações do uso desses equipamentos na prática transfusional de enfermagem. revisão integrativa de literatura nas bases de dados Pubmed/Medline, Scopus, Biblioteca Virtual em Saúde, SciELO, Web of Science e Cochrane, utilizando os descritores "bombas de infusão", "transfusão de sangue", "transfusão de eritrócitos" e "hemólise". A data inicial não foi delimitada e a final foi dezembro de 2014. Foram identificados 17 artigos de acordo com os critérios de inclusão e exclusão. Todas as publicações incluídas eram estudos experimentais in vitro e abordavam o uso de bombas de infusão na terapêutica transfusional. A síntese dos dados foi apresentada em quadro sinóptico e a análise gerou duas categorias relevantes: lesão celular e mecanismo de infusão. bombas de infusão podem ser deletérias às hemácias de acordo o mecanismo de infusão, sendo que as peristálticas lineares foram mais predisponentes à hemólise. A lesão celular foi relacionada à liberação plasmática de marcadores, predominando a hemoglobina livre e potássio. Reitera-se a necessidade de pesquisas adicionais e investimentos tecnológicos para nortear o desenvolvimento de protocolos que promovam prática segura e que subsidiem futuros estudos clínicos. identificar en la literatura la producción científica acerca de los efectos de la bomba de transfusión en la administración de glóbulos rojos y evaluar las implicaciones del uso de esos equipos en la práctica transfusional de enfermería. revisión integradora de literatura en las bases de datos Pubmed/Medline, Scopus, Biblioteca Virtual en Salud, SciELO, Web of Science y Cochrane, utilizando los descriptores "bombas de infusión", "transfusión de sangre", "transfusión de eritrocitos" y "hemolisis". La fecha inicial no fue delimitada y la final fue en diciembre de 2014. Fueron identificados 17 artículos de acuerdo con los criterios de inclusión y exclusión. todas las publicaciones incluidas eran estudios experimentales in vitro y abordaban el uso de bombas de infusión en la terapéutica transfusional. La síntesis de los datos se presenta en un cuadro sinóptico y el análisis generó dos categorías relevantes: lesión celular y mecanismo de transfusión. las bombas de infusión pueden ser perjudiciales para los glóbulos rojos de acuerdo el mecanismo de transfusión, siendo que las peristálticas lineares fueron más predisponentes para la hemolisis. La lesión celular fue relacionada a la liberación plasmática de marcadores, predominando la hemoglobina libre y el potasio. Se reitera la necesidad de realizar investigaciones adicionales e inversiones tecnológicas que puedan orientar el desarrollo de protocolos que promuevan la práctica segura y que ayuden a futuros estudios clínicos.
STS-40 MS Jernigan works at SLS-1 Rack 1 workstation with intravenous system
1991-06-14
STS040-30-008 (5-14 June 1991) --- Astronaut Tamara E. Jernigan, after applying a blood pressure cuff to an experiment, watches it in operation. The experiment is the intravenous infusion pump. The device is being considered for use on Space Station Freedom's Health Maintenance Facility. Dr. Jernigan is one of seven crew members supporting the nine-day Spacelab Life Sciences (SLS-1) mission aboard the Earth-orbiting Space Shuttle Columbia.
Medical technology at home: safety-related items in technical documentation.
Hilbers, Ellen S M; de Vries, Claudette G J C A; Geertsma, Robert E
2013-01-01
This study aimed to investigate the technical documentation of manufacturers on issues of safe use of their device in a home setting. Three categories of equipment were selected: infusion pumps, ventilators, and dialysis systems. Risk analyses, instructions for use, labels, and post market surveillance procedures were requested from manufacturers. Additionally, they were asked to fill out a questionnaire on collection of field experience, on incidents, and training activities. Specific risks of device operation by lay users in a home setting were incompletely addressed in the risk analyses. A substantial number of user manuals were designed for professionals, rather than for patients or lay carers. Risk analyses and user information often showed incomplete coherence. Post market surveillance was mainly based on passive collection of field experiences. Manufacturers of infusion pumps, ventilators, and dialysis systems pay insufficient attention to the specific risks of use by lay persons in home settings. It is expected that this conclusion is also applicable for other medical equipment for treatment at home. Manufacturers of medical equipment for home use should pay more attention to use errors, lay use and home-specific risks in design, risk analysis, and user information. Field experiences should be collected more actively. Coherence between risk analysis and user information should be improved. Notified bodies should address these aspects in their assessment. User manuals issued by institutions supervising a specific home therapy should be drawn up in consultation with the manufacturer.
An overlooked alliance: using human factors engineering to reduce patient harm.
Perry, Shawna J
2004-08-01
Although human factors engineering (HFE) is considered only in relationship to the design of medical devices or information systems technology, human factors issues arise in many aspects of work in health care organizations. In one scenario, the resuscitation stretcher would not pass through the ED door closest to radiology. Many clinical work spaces were never formally designed for the work currently being performed in them; instead, they were adapted from existing space originally designed for a different use. In a second scenario, infusion pump malfunction was not apparent. The patient experienced a near miss secondary to poor design; users thought that the infusion pump had been turned off when it was not. Health care can significantly benefit from the incorporation of HFE into the workplace. Introductory classes in medical and nursing schools on HFE will assist students in detecting HFE-related issues, making them less likely to suffer with them or overlook them once in clinical practice. More extensive training for patient safety and risk managers, that is, at a minimum, a certificate-level course from an HFE program, would enhance case and root cause analyses since these issues are rarely factored in. Collaboration with HFE experts and use of HFE principles may not make health care fool-proof, but it will make it less dependent on improvisation and ingenuity to protect patients from the system's vulnerabilities.
Wallin, Mats K E B; Marve, Therese; Hakansson, Peter K
2005-11-01
Hospitals rely on pagers and ordinary telephones to reach staff members in emergency situations. New telecommunication technologies such as General Packet Radio Service (GPRS), the third generation mobile phone system Universal Mobile Telecommunications System (UMTS), and Wireless Local Area Network (WLAN) might be able to replace hospital pagers if they are electromagnetically compatible with medical devices. In this study, we sought to determine if GPRS, UMTS (Wideband Code Division Multiple Access-Frequency Division Duplex [WCDMA FDD]), and WLAN (IEEE 802.11b) transmitted signals interfere with life-supporting equipment in the intensive care and operating room environment. According to United States standard, ANSI C63.18-1997, laboratory tests were performed on 76 medical devices. In addition, clinical tests during 11 operations and 100 h of intensive care were performed. UMTS and WLAN signals caused little interference. Devices using these technologies can be used safely in critical care areas and during operations, but direct contact between medical devices and wireless communication devices ought to be avoided. In the case of GPRS, at a distance of 50 cm, it caused an older infusion pump to alarm and stop infusing; the pump had to be reset. Also, 10 cases of interference with device displays occurred. GPRS can be used safely at a distance of 1 m. Terminals/cellular phones using these technologies should be allowed without restriction in public areas because the risk of interference is minimal.
Gilgen, Emily
2014-01-01
Background: We assessed the impact of perceived insulin pump usability on attitudes toward insulin pump therapy in diabetic individuals currently treated with multiple daily insulin injections (MDI). Method: This comparative, single-arm study recruited 28 adults with type 1 (n = 16) and insulin-treated type 2 diabetes (n = 12) to evaluate 2 current insulin pumps: Medtronic Revel 723 (Pump 1), Asante Snap Insulin Pump (Pump 2). Participants were randomized 1:1 to 1 of 2 assessment sequences: Pump 1 followed by Pump 2; and Pump 2 followed by Pump 1. Structured observational protocols were utilized to assess participants’ ability and time required to learn/perform common tasks associated with pump setup/use. Participants used a modified version of the System Usability Scale (SUS) and investigator-developed questionnaires to rate pump usability and task difficulty; pre-post questionnaires assessed changes in attitudes toward insulin pump therapy. Results: All participants completed the study. SUS scores showed Pump 2 to be more usable than Pump 1 on all usability attributes. Participants rated Pump 2 more positively than Pump 1, overall mean SUS scores of 5.7 versus 4.1 respectively, F(1, 52) = 32.7, P < .001, and SUS scores were higher if participants used the Pump 2 last, 5.3 versus 4.4 for Pump 1 last, F(1, 52) = 10.8, P < .01. Pump 2 was preferred for all tasks: manual bolus (86%), bolus calculation (71%), managing basal rates (93%), interpreting alarms (96%), transferring settings (100%), changing insulin and infusion sets (93%), all P < .05. Conclusions: Perceptions of pump usability can directly impact acceptance and use of features that may benefit those who wear them. Simpler pump devices that decrease perceptions of complexity may encourage broader use of this technology. PMID:25269659
2013-01-01
Background The use of radiofrequency identification (RFID) in healthcare is increasing and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have documented that RFID can interfere with medical devices. The majority of past studies have concentrated on implantable medical devices such as implantable pacemakers and implantable cardioverter defibrillators (ICDs). This study examined EMC between RFID systems and non-implantable medical devices. Methods Medical devices were exposed to 19 different RFID readers and one RFID active tag. The RFID systems used covered 5 different frequency bands: 125–134 kHz (low frequency (LF)); 13.56 MHz (high frequency (HF)); 433 MHz; 915 MHz (ultra high frequency (UHF])) and 2.4 GHz. We tested three syringe pumps, three infusion pumps, four automatic external defibrillators (AEDs), and one ventilator. The testing procedure is modified from American National Standards Institute (ANSI) C63.18, Recommended Practice for an On-Site, Ad Hoc Test Method for Estimating Radiated Electromagnetic Immunity of Medical Devices to Specific Radio-Frequency Transmitters. Results For syringe pumps, we observed electromagnetic interference (EMI) during 13 of 60 experiments (22%) at a maximum distance of 59 cm. For infusion pumps, we observed EMI during 10 of 60 experiments (17%) at a maximum distance of 136 cm. For AEDs, we observed EMI during 18 of 75 experiments (24%) at a maximum distance of 51 cm. The majority of the EMI observed was classified as probably clinically significant or left the device inoperable. No EMI was observed for all medical devices tested during exposure to 433 MHz (two readers, one active tag) or 2.4 GHz RFID (two readers). Conclusion Testing confirms that RFID has the ability to interfere with critical medical equipment. Hospital staff should be aware of the potential for medical device EMI caused by RFID systems and should be encouraged to perform on-site RF immunity tests prior to RFID system deployment or prior to placing new medical devices in an RFID environment. The methods presented in this paper are time-consuming and burdensome and suggest the need for standard test methods for assessing the immunity of medical devices to RFID systems. PMID:23845013
Seidman, Seth J; Guag, Joshua W
2013-07-11
The use of radiofrequency identification (RFID) in healthcare is increasing and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have documented that RFID can interfere with medical devices. The majority of past studies have concentrated on implantable medical devices such as implantable pacemakers and implantable cardioverter defibrillators (ICDs). This study examined EMC between RFID systems and non-implantable medical devices. Medical devices were exposed to 19 different RFID readers and one RFID active tag. The RFID systems used covered 5 different frequency bands: 125-134 kHz (low frequency (LF)); 13.56 MHz (high frequency (HF)); 433 MHz; 915 MHz (ultra high frequency (UHF])) and 2.4 GHz. We tested three syringe pumps, three infusion pumps, four automatic external defibrillators (AEDs), and one ventilator. The testing procedure is modified from American National Standards Institute (ANSI) C63.18, Recommended Practice for an On-Site, Ad Hoc Test Method for Estimating Radiated Electromagnetic Immunity of Medical Devices to Specific Radio-Frequency Transmitters. For syringe pumps, we observed electromagnetic interference (EMI) during 13 of 60 experiments (22%) at a maximum distance of 59 cm. For infusion pumps, we observed EMI during 10 of 60 experiments (17%) at a maximum distance of 136 cm. For AEDs, we observed EMI during 18 of 75 experiments (24%) at a maximum distance of 51 cm. The majority of the EMI observed was classified as probably clinically significant or left the device inoperable. No EMI was observed for all medical devices tested during exposure to 433 MHz (two readers, one active tag) or 2.4 GHz RFID (two readers). Testing confirms that RFID has the ability to interfere with critical medical equipment. Hospital staff should be aware of the potential for medical device EMI caused by RFID systems and should be encouraged to perform on-site RF immunity tests prior to RFID system deployment or prior to placing new medical devices in an RFID environment. The methods presented in this paper are time-consuming and burdensome and suggest the need for standard test methods for assessing the immunity of medical devices to RFID systems.
Family perceptions of insulin pump adverse events in children and adolescents.
Wheeler, Benjamin J; Donaghue, Kim C; Heels, Kristine; Ambler, Geoffrey R
2014-04-01
Insulin pumps (for continuous subcutaneous insulin infusion [CSII]) are used widely in type 1 diabetes mellitus. Although there has been considerable study of outcomes, there are few recent data on CSII-associated adverse events and no data on family perceptions of adverse events and their confidence in dealing with them. We approached all families of children and adolescents ≤ 19 years of age on CSII attending the diabetes clinic over a 16-week clinic cycle. Participants completed a retrospective questionnaire examining issues over the previous 12 months. Data on pump adverse events as well as answers to questions pertaining to education and confidence were collected. Our survey received a response rate of 99%, with 235 of the 238 families approached participating. In the preceding 12 months, 104 of 230 (45%) had reported at least one pump-related adverse event (either mechanical or set-related), with an associated 52 of 229 (23%) resulting in pump replacement. This equated to a minimum incidence density of 53 adverse events/100 person-years. Additionally, 18 of 230 (8%) reported a hospital admission or emergency department attendance as a consequence. Pump malfunction and infusion set/site failures were the most common events reported, with one or more events in 58 of 104 (56%) and 47 of 104 (45%), respectively. Adverse events, excluding set/site failures, were associated with older age (13.1 ± 3.4 years vs. 11.9 ± 4 years; P = 0.02). This is the first study to look at family perceptions of adverse events while using modern CSII. It highlights a high self-reported rate of CSII-related adverse events, pump replacement, and subsequent presentation to the hospital. Potential areas for additional targeted education are identified. Further prospective study examining pump adverse event characteristics and incidence is warranted.
Ravindranath, N; Ramesh, V; Krishnamurthy, H N; Rao, A J; Moudgal, R N
1992-03-01
To study the efficacy of long-term buserelin acetate infusion to desensitize pituitary and block testicular function in adult male monkeys (Macaca radiata). Proven fertile male monkeys exhibiting normal testicular function. Each of the control (n = 5) and experimental monkeys (n = 10) received a fresh miniosmotic pump every 21 days, whereas pumps in controls delivered vehicle of experimentals released 50 micrograms buserelin acetate every 24 hours. On day 170 (renewed every 60 days) a silastic capsule containing crystalline testosterone (T) was implanted in the experimental monkeys. At the end of 3 years, treatment was stopped, and recovery of testicular function and fertility monitored. (1) Treatment resulted in marked reduction of nocturnal but not basal serum T; (2) the pituitary remained desensitized to buserelin acetate throughout the 3-year period; (3) animals were largely azoospermic with occasional oligospermia exhibited by two monkeys; and (4) withdrawal of treatment restored testicular function, with 70% of animals regaining fertility. Long-term infertility (but restorable) can be induced in male monkeys by constant infusion of buserelin acetate and T.
Buras, Eric D; Weatherup, Emily; Wyckoff, Jennifer
2018-01-01
Ectopic insulin-like growth factor (IGF)-2 production is a rare complication of an array of epithelial and mesenchymal tumors, and can clinically manifest as life-threatening hypoglycemia. A 49-year-old woman with 13-year history of metastatic hemangiopericytoma, previously treated with multiple rounds of chemotherapy and palliative radiation, presented to the emergency department after a hypoglycemic seizure. On arrival, glucose was 18 mg/dL (1.0 mmol/L) and required continuous dextrose infusion for maintenance within normal limits. Insulin was <2.0 μU/mL, C-peptide 0.1 ng/mL, and beta-hydroxybutyrate <0.2 mmol/L. Random cortisol was 21 μg/dL; sulfonylurea screen, and insulin antibodies were negative. IGF-2 level was 1320 ng/mL; IGF-1 was within normal limits and IGF binding protein (BP)-3 suppressed. Dexamethasone, started at 6 mg twice daily, allowed discontinuation of the glucose infusion. Given concern for nocturnal hypoglycemia, and patient interest in steroid-sparing anti-hypoglycemic regimen, she was also started on overnight continuous subcutaneous glucagon infusion via insulin pump. She was discharged with instructions to maintain a diet high in complex carbohydrates during the day, while utilizing glucagon pump at night. She was also started on continuous glucose monitoring system (CGMS) with an alarm to warn of hypoglycemia. Glucagon infusion rate was later titrated based on CGMS readings. Abdominal CT revealed increasing size of a right upper quadrant mass not previously subjected to radiotherapy. After radiation to this area, hypoglycemia improved, allowing further glucagon titration. In parallel, IGF-2 level declined to 380 ng/mL. Ectopic IGF-2 production is a rare but often fatal complication of many cancers, and should be considered on the differential diagnosis in patients with malignancy and unexplained hypoglycemia. Once hypoglycemia is diagnosed, patients often have end-stage disease. While treatment of the causative tumor is the only definitive intervention, anti-hypoglycemia therapy is a life-saving, temporizing measure. In this case, the patient attained euglycemia and survived 3 months after presentation before ultimately succumbing to other malignancy-related complications. Given efficacy in management of hypoglycemia while awaiting definitive tumor-directed therapy, we submit nighttime subcutaneous glucagon infusion and CGMS are valuable additions to the physician's armamentarium in managing this condition.
Masoumi, Gholamreza; Pour, Evaz Hidar; Sadeghpour, Ali; Ziayeefard, Mohsen; Alavi, Mostapha; Anbardan, Sanam Javid; Shirani, Shahin
2012-02-01
On-pump coronary artery bypass graft (CABG) surgery impairs gas exchange in the early postoperative period. The main object on this study was evaluation of changes in arterial blood gas values in patients underwent on pump CABG surgery receiving different dose of intravenous nitroglycerin (NTG). sixty-seven consecutive patients undergoing elective on-pump CABG randomly enrolled into three groups receiving NTG 50 μg/min (Group N1, n =67), 100 μg/min (Group N2, n = 67), and 150 μg/min (Group N3, n = 67). Arterial blood gas (ABG) tensions were evaluated just before induction of anesthesia, during anesthesia, at the end of warming up period, and 6 h after admission to the intensive care unit. Pao2 and PH had the highest value during surgery in Group N1, Group N2, and Group N3. No significant difference was noted in mean values of Pao2 and PH during surgery between three groups (P > 0.05). There was no significant difference in HCO3 values in different time intervals among three groups (P > 0.05). our results showed that infusing three different dosage of NTG (50, 100, and 150 μg/min) had no significant effect on ABG tensions in patients underwent on-pump CABG surgery.
Peniche, Alec; Poree, Lawrence; Schumacher, Mark; Yu, Xiaobing
2018-06-01
Intrathecal patient-controlled analgesia (IT-PCA) through implanted intrathecal infusion pumps has been increasingly utilized for severe cancer and chronic noncancer pain management. However, its application for acute postoperative pain management has not been reported to date. We present a case of a patient with an implanted intrathecal pump for chronic nonmalignant back pain who underwent an extensive spinal fusion surgery. The IT-PCA functionality of her intrathecal pump was successfully integrated into her postoperative multimodal pain regimen. Hence, IT-PCA can be safely incorporated into acute postoperative pain management with vigilant monitoring and close multidisciplinary collaboration.
Chemical Stability of Telavancin in Elastomeric Pumps☆
Sand, Patrick; Aladeen, Traci; Kirkegaard, Paul; LaChance, Dennis; Slover, Christine
2015-01-01
Background VIBATIV is a once-daily, injectable lipoglycopeptide antibiotic approved in the U.S. for the treatment of hospital-acquired and ventilator-associated bacterial pneumonia (HABP/VABP) caused by susceptible isolates of Staphylococcus aureus when alternative treatments are not suitable. In addition, VIBATIV is approved in the U.S. for the treatment of adult patients with complicated skin & skin structure infections (cSSSI) caused by susceptible isolates of Gram-positive bacteria, including Staphylococcus aureus, both methicillin-susceptible (MSSA) and methicillin-resistant (MRSA) strains. Objective To evaluate the chemical stability of telavancin (Vibativ; Theravance Biopharma US, Inc, Northbrook, Illinois), a lipoglycopeptide antibiotic with activity against methicillin-resistant Staphylococcus aureus, in 2 types of elastomeric pumps, the Intermate Infusion System (Baxter International Inc) and the Homepump Eclipse (I-Flow Corporation). Methods Different sizes of the Baxter (Ontario, Canada) (105 mL and 275 mL) and I-Flow (Stoughton, Massachusetts) (100 mL and 250 mL) pumps were compared with glass controls. The telavancin drug product was reconstituted and diluted to concentrations of 0.6 mg/mL and 8.0 mg/mL using either 0.9% saline, 5% dextrose in water, or sterilized water for injection (0.6 mg/mL telavancin) or saline (8.0 mg/mL telavancin) followed by Ringer’s Lactate solution. Pumps were filled and stored at 2°C to 8°C, protected from light. Aliquots from both pump types and for all telavancin reconstitution/dilution schemes and concentrations were taken over a period of 8 days and analyzed for appearance, pH, telavancin concentration and purity, and degradation products. Results The pH of all pump solutions remained consistent throughout the 8-day analysis period, within a range of 4.6 to 5.7 for the 0.6 mg/mL and 4.4 to 4.9 for the 8.0 mg/mL telavancin solutions. There was no significant change in the chromatographic purity for any of the pump solutions examined. All decreases in telavancin concentration were ≤2.7%. Comparison of each test sample solution to the corresponding glass control indicated no loss of active drug due to absorption by the elastomeric material of the pumps. The greatest increase in the amount of total degradants observed over the 8-day period was ~0.7 w/w%. Conclusions The results of this study indicate that telavancin remains chemically stable when diluted in the Intermate Infusion System and the Homepump Eclipse elastomeric pumps and stored at 2°C to 8°C for up to 8 days protected from light at the concentration range and dilution schemes evaluated. PMID:26649079
The use of an "unnatural" prostaglandin in the termination of pregnancy.
Gillespie, A; Beazley, J M; van Dorp, D A
1971-04-01
An unnatural prostaglandin (PG) (prepared by biosynthesis using the method described by Vonkerman et al.) was used to terminate midtrimester pregnancy in 3 primiparous patients aged 21-24. The PG was administered intravenously using a Palmer slow infusion pump. The patients were monitored continuously with particular attention given to pulse, respiration, blood pressure, uterine contractions and cervical dilatation. All 3 cases successfully aborted. Effective infusion rate was similar to that of PGE1 and PGE2 (5-6 mcg/minute) and side effects were trivial (minimal skin flushing, vomiting, mild urticarial reaction). 2 of the patients aborted 8 and 22 hours after infusion stopped without being conscious of continuing uterine activity; the 3rd patient necessitated infusion on the 2nd day and exhibited increased response to the infusion; however, the PG supply was exhausted and syntocinon infusion facilitated the complete abortion. This study shows that this synthetic prostaglandin containing an uneven number of carbon atoms is pharmacologically active and can induce contractions in the intact human pregnant uterus.
Making Medical Devices Safer at Home
... and maintain home use devices, which include blood glucose monitors, infusion pumps (a device that delivers fluids, including nutrients and medications, into a patient's body) and respirators. These efforts include issuing a draft ...
Battelino, Tadej; Danne, Thomas; Hovorka, Roman; Jarosz‐Chobot, Przemyslawa; Renard, Eric
2015-01-01
Summary The level of glycaemic control necessary to achieve optimal short‐term and long‐term outcomes in subjects with type 1 diabetes mellitus (T1DM) typically requires intensified insulin therapy using multiple daily injections or continuous subcutaneous insulin infusion. For continuous subcutaneous insulin infusion, the insulins of choice are the rapid‐acting insulin analogues, insulin aspart, insulin lispro and insulin glulisine. The advantages of continuous subcutaneous insulin infusion over multiple daily injections in adult and paediatric populations with T1DM include superior glycaemic control, lower insulin requirements and better health‐related quality of life/patient satisfaction. An association between continuous subcutaneous insulin infusion and reduced hypoglycaemic risk is more consistent in children/adolescents than in adults. The use of continuous subcutaneous insulin infusion is widely recommended in both adult and paediatric T1DM populations but is limited in pregnant patients and those with type 2 diabetes mellitus. All available rapid‐acting insulin analogues are approved for use in adult, paediatric and pregnant populations. However, minimum patient age varies (insulin lispro: no minimum; insulin aspart: ≥2 years; insulin glulisine: ≥6 years) and experience in pregnancy ranges from extensive (insulin aspart, insulin lispro) to limited (insulin glulisine). Although more expensive than multiple daily injections, continuous subcutaneous insulin infusion is cost‐effective in selected patient groups. This comprehensive review focuses on the European situation and summarises evidence for the efficacy and safety of continuous subcutaneous insulin infusion, particularly when used with rapid‐acting insulin analogues, in adult, paediatric and pregnant populations. The review also discusses relevant European guidelines; reviews issues that surround use of this technology; summarises the effects of continuous subcutaneous insulin infusion on patients' health‐related quality of life; reviews relevant pharmacoeconomic data; and discusses recent advances in pump technology, including the development of closed‐loop ‘artificial pancreas’ systems. © 2015 The Authors. Diabetes/Metabolism Research and Reviews Published by John Wiley & Sons Ltd. PMID:25865292
Effect of different infusion regimens on colonic motility and efficacy of colostomy irrigation.
Gattuso, J M; Kamm, M A; Myers, C; Saunders, B; Roy, A
1996-10-01
The colonic motility response and short-term clinical effectiveness of colonic irrigation was studied in five patients with an end-colostomy, each of whom was studied on up to six occasions, using volumes of 500 and 1500 ml water infused under gravity and over a period of 2.5 and 5 min with a pump. The median baseline colonic luminal pressure was 14 cmH2O and rose to 42 cmH2O with a 500-ml infusion, and to 74 cmH2O with a 1500-ml infusion. Irrigation induced high-pressure (over 200 cmH2O) propagated waves which caused the efflux of colonic contents. These were more numerous after a 1500- than a 500-ml infusion (median 4.5 versus 2.0 respectively). There was no difference between the two volumes infused in the incidence of colostomy break-through before subsequent irrigation. Colostomy irrigation with 500-1500 ml water appears to produce intracolonic pressure rises that are safe. These volumes can be infused rapidly under gravity alone.
Pierce, Eric T; Kumar, Vikram; Zheng, Hui; Peterfreund, Robert A
2013-03-01
Gravity-driven micro-drip infusion sets allow control of medication dose delivery by adjusting drops per minute. When the roller clamp is fully open, flow in the drip chamber can be a continuous fluid column rather than discrete, countable, drops. We hypothesized that during this "wide-open" state, drug delivery becomes dependent on factors extrinsic to the micro-drip set and is therefore difficult to predict. We conducted laboratory experiments to characterize volume delivery under various clinically relevant conditions of wide-open flow in an in vitro laboratory model. A micro-drip infusion set, plugged into a bag of normal saline, was connected to a high-flow stopcock at the distal end. Vertically oriented IV catheters (gauges 14-22) were connected to the stopcock. The fluid meniscus height in the bag was fixed (60-120 cm) above the outflow point. The roller clamp on the infusion set was in fully open position for all experiments resulting in a continuous column of fluid in the drip chamber. Fluid volume delivered in 1 minute was measured 4 times with each condition. To model resistive effects of carrier flow, volumetric infusion pumps were used to deliver various flow rates of normal saline through a carrier IV set into which a micro-drip infusion was "piggybacked." We also compared delivery by micro-drip infusion sets from 3 manufacturers. The volume of fluid delivered by gravity-driven infusion under wide-open conditions (continuous fluid column in drip chamber) varied 2.9-fold (95% confidence interval, 2.84-2.96) depending on catheter size and fluid column height. Total model resistance of the micro-drip with stopcock and catheter varied with flow rate. Volume delivered by the piggybacked micro-drip decreased up to 29.7% ± 0.8% (mean ± SE) as the carrier flow increased from 0 to 1998 mL/min. Delivery characteristics of the micro-drip infusion sets from 3 different manufacturers were similar. Laboratory simulation of clinical situations with gravity-driven micro-drip infusion sets under wide-open flow conditions revealed that infusion rate (drug and/or volume delivery) can vary widely depending on extrinsic factors including catheter size, fluid column height, and carrier flow. The variable resistance implies nonlaminar flow in the micro-drip model that cannot be easily predicted mathematically. These findings support the use of mechanical pumps instead of gravity-driven micro-drips to enhance the precision and safety of IV infusions, especially for vasoactive drugs.
Effects of atmospheric pressure conditions on flow rate of an elastomeric infusion pump.
Wang, Jong; Moeller, Anna; Ding, Yuanpang Samuel
2012-04-01
The effects of pressure conditions, both hyperbaric and hypobaric, on the flow rate of an elastomeric infusion pump were investigated. The altered pressure conditions were tested with the restrictor outlet at two different conditions: (1) at the same pressure condition as the Infusor elastomeric balloon and (2) with the outlet exposed to ambient conditions. Five different pressure conditions were tested. These included ambient pressure (98-101 kilopascals [kPa]) and test pressures controlled to be 10 or 20 kPa below or 75 or 150 kPa above the ambient pressure. A theoretical calculation based on the principles of fluid mechanics was also used to predict the pump's flow rate at various ambient conditions. The conditions in which the Infusor elastomeric pump and restrictor outlet were at the same pressure gave rise to average flow rates within the ±10% tolerance of the calculated target flow rate of 11 mL/hr. The flow rate of the Infusor pump decreased when the pressure conditions changed from hypobaric to ambient. The flow rate increased when the pressure conditions changed from hyperbaric to ambient. The flow rate of the Infusor elastomeric pump was not affected when the balloon reservoir and restrictor outlet were at the same pressure. The flow rate varied from 58.54% to 377.04% of the labeled flow rate when the pressure applied to the reservoir varied from 20 kPa below to 150 kPa above the pressure applied to the restrictor outlet, respectively. The maximum difference between observed flow rates and those calculated by applying fluid mechanics was 4.9%.
Choi, Cheol Woong; Kang, Dae Hwan; Kim, Hyung Wook; Hong, Joung Boom; Park, Su Bum; Kim, Su Jin; Cho, Mong
2015-07-01
A high dose of continuous intravenous infusion of proton pump inhibitor (PPI) is the standard treatment for peptic ulcer bleeding. The optimal dose for the prevention of bleeding after endoscopic submucosal dissection (ESD) is unclear. The purpose of this study was to determine whether stronger acid suppression more effectively prevents bleeding and high risk ulcer stigma (HRS) after gastric ESD. A total of 273 patients who underwent ESD were randomly assigned to one of two treatment groups: the continuous infusion group and the bolus injection group. Second-look endoscopy was performed on the following day after ESD. The incidences and risk factors of HRS identified by second-look endoscopy and delayed bleeding were analyzed. There were no differences in the incidences of HRS and delayed bleeding between two treatment groups. The incidence of HRS was 15.8 % (43/273) and the gross morphology (flat or depressed) was identified as a significant factor associated with HRS. The incidence of delayed bleeding was 8.4 % (23/273) and the gross morphology (flat) and the presence of submucosal invasive cancer were identified as the associated risk factors for delayed bleeding. The incidences of delayed bleeding and HRS identified by second-look endoscopy were not affected by PPI infusion methods. Flat or depressed morphologic lesions and submucosal invasive cancer should be closely monitored.
Zochodne, D W; Murray, M; Nag, S; Riopelle, R J
1994-02-01
We explored the effects of chronic lumbar intrathecal NMDA infusion (mini-osmotic pumps) in Sprague-Dawley rats on motor and sensory axon integrity. Several different infusion protocols, each given over a 4 week period were examined: 0.15 M NMDA in phosphate buffered saline; phosphate buffered saline without NMDA; and 0.20 M magnesium sulfate plus 0.15 M NMDA; 0.35 M NMDA. In two additional protocols, 0.15 M NMDA or phosphate buffered saline were infused for a total of 8 weeks. Within 1-2 weeks of the onset of NMDA, but not phosphate buffered saline infusions, the rats exhibited irritability, circling, biting and excessive grooming resulting in loss of hair, and skin ulcerations from autotomy localized to lumbar and sacral innervated dermatomes. Co-infusion of NMDA with magnesium sulfate almost completely prevented these findings. The behavioural changes were not associated with abnormalities of sensory or motor conduction. Intrathecal infusion of NMDA induces a chronic "central" experimental pain disorder in rats, localized to the cord segment with the greatest exposure to the infusion, without involvement of peripheral sensory axons and sparing the axonal integrity of anterior horn cells.
Chau, Destiny F; Vasilopoulos, Terrie; Schoepf, Miriam; Zhang, Christina; Fahy, Brenda G
2016-09-01
Complex surgical and critically ill pediatric patients rely on syringe infusion pumps for precise delivery of IV medications. Low flow rates and in-line IV filter use may affect drug delivery. To determine the effects of an in-line filter to remove air and/or contaminants on syringe pump performance at low flow rates, we compared the measured rates with the programmed flow rates with and without in-line IV filters. Standardized IV infusion assemblies with and without IV filters (filter and control groups) attached to a 10-mL syringe were primed and then loaded onto a syringe pump and connected to a 16-gauge, 16-cm single-lumen catheter. The catheter was suspended in a normal saline fluid column to simulate the back pressure from central venous circulation. The delivered infusate was measured by gravimetric methods at predetermined time intervals, and flow rate was calculated. Experimental trials for initial programmed rates of 1.0, 0.8, 0.6, and 0.4 mL/h were performed in control and filter groups. For each trial, the flow rate was changed to double the initial flow rate and was then returned to the initial flow rate to analyze pump performance for titration of rates often required during medication administration. These conditions (initial rate, doubling of initial rate, and return to initial rate) were analyzed separately for steady-state flow rate and time to steady state, whereas their average was used for percent deviation analysis. Differences between control and filter groups were assessed using Student t tests with adjustment for multiplicity (using n = 3 replications per group). Mean time from 0 to initial flow (startup delay) was <1 minute in both groups with no statistical difference between groups (P = 1.0). The average time to reach steady-state flow after infusion startup or rate changes was not statistically different between the groups (range, 0.8-5.5 minutes), for any flow rate or part of the trial (initial rate, doubling of initial rate, and return to initial rate), although the study was underpowered to detect small time differences. Overall, the mean steady-state flow rate for each trial was below the programmed flow rate with negative mean percent deviations for each trial. In the 1.0-mL/h initial rate trial, the steady-state flow rate attained was lower in the filter than the control group for the initial rate (P = 0.04) and doubling of initial rate (P = 0.04) with a trend during the return to initial rate (P = 0.06), although this same effect was not observed when doubling the initial rate trials of 0.8 or 0.6 mL/h or any other rate trials compared with the control group. With low flow rates used in complex surgical and pediatric critically ill patients, the addition of IV filters did not confer statistically significant changes in startup delay, flow variability, or time to reach steady-state flow of medications administered by syringe infusion pumps. The overall flow rate was lower than programmed flow rate with or without a filter.
Rabbone, Ivana; Barbetti, Fabrizio; Marigliano, Marco; Bonfanti, Riccardo; Piccinno, Elvira; Ortolani, Federica; Ignaccolo, Giovanna; Maffeis, Claudio; Confetto, Santino; Cerutti, Franco; Zanfardino, Angela; Iafusco, Dario
2016-08-01
Neonatal diabetes mellitus (NDM) is defined as hyperglycemia and impaired insulin secretion with onset within 6 months of birth. While rare, NDM presents complex challenges regarding the management of glycemic control. The availability of continuous subcutaneous insulin infusion pumps (CSII) in combination with continuous glucose monitoring systems (CGM) provides an opportunity to monitor glucose levels more closely and deliver insulin more safely. We report four cases of young infants with NDM successfully treated with CSII and CGM. Moreover, in two cases with Kir 6.2 mutation, we describe the use of CSII in switching therapy from insulin to sulfonylurea treatment. Insulin pump requirement for the 4 neonatal diabetes cases was the same regardless of disease pathogenesis and c-peptide levels. No dilution of insulin was needed. The use of an integrated CGM system helped in a more precise control of BG levels with the possibility of several modifications of insulin basal rates. Moreover, as showed in the first two case-reports, when the treatment was switched from insulin to glibenclamide, according to identification of Kir 6.2 mutation and diagnosis of NPDM, the CSII therapy demonstrated to be helpful in allowing gradual insulin suspension and progressive introduction of sulfonylurea. During the neonatal period, the use of CSII therapy is safe, more physiological, accurate and easier for the insulin administration management. Furthermore, CSII therapy is safe during the switch of therapy from insulin to glibenclamide for infants with permanent neonatal diabetes mellitus.
A fuzzy logic controller for hormone administration using an implantable pump
NASA Technical Reports Server (NTRS)
Coles, L. Stephen; Wells, George H., Jr.
1994-01-01
This paper describes the requirements for a Fuzzy Logic Controller for the physiologic administration of hormones by means of a FDA-approved surgically implantable infusion pump. Results of a LabVIEW computer simulation for the administration of insulin for diabetic adult patients as well as human growth hormone for pediatric patients are presented. A VHS video tape of the simulation in action has been prepared and is available for viewing.
Continuous intraputamenal convection-enhanced delivery in adult rhesus macaques.
Fan, Xiaotong; Nelson, Brian D; Ai, Yi; Stiles, David K; Gash, Don M; Hardy, Peter A; Zhang, Zhiming
2015-12-01
Assessing the safety and feasibility of chronic delivery of compounds to the brain using convection-enhanced delivery (CED) is important for the further development of this important therapeutic technology. The objective of this study was to follow and model the distribution of a compound delivered by CED into the putamen of rhesus monkeys. The authors sequentially implanted catheters into 4 sites spanning the left and right putamen in each of 6 rhesus monkeys. The catheters were connected to implanted pumps, which were programmed to deliver a 5-mM solution of the MRI contrast agent Gd-DTPA at 0.1 μl/minute for 7 days and 0.3 μl/minute for an additional 7 days. The animals were followed for 28 days per implant cycle during which they were periodically examined with MRI. All animals survived the 4 surgeries with no deficits in behavior. Compared with acute infusion, the volume of distribution (Vd) increased 2-fold with 7 days of chronic infusion. Increasing the flow rate 3-fold over the next week increased the Vd an additional 3-fold. Following withdrawal of the compound, the half-life of Gd-DTPA in the brain was estimated as 3.1 days based on first-order pharmacokinetics. Histological assessment of the brain showed minimal tissue damage limited to the insertion site. These results demonstrate several important features in the development of a chronically implanted pump and catheter system: 1) the ability to place catheters accurately in a predetermined target; 2) the ability to deliver compounds in a chronic fashion to the putamen; and 3) the use of MRI and MR visible tracers to follow the evolution of the infusion volume over time.
Gandhi, Hemang; Sarvaia, Alpesh; Malhotra, Amber; Acharya, Himanshu; Shah, Komal; Rajavat, Jeevraj
2018-01-01
The prevalence of diabetes mellitus in patients requiring coronary artery bypass grafting (CABG) is noticeably high (20%-30%). These patients have inferior perioperative outcome, reduced long-term survival, and high risk of recurrent episodes of angina. To improve perioperative outcome surgical unit defined satisfactory glycemic control is desired during this period. Hence, the aim of our study is to compare the efficacy of glargine insulin combination with continuous human insulin infusion for perioperative glycemic control in patients with diabetes undergoing CABG. Fifty Patients, who were posted for off-pump CABG with diabetes mellitus type II, were randomized in two group, Group I normal saline + human insulin infusion during the perioperative period, Group II (glargine group): Glargine + human insulin infusion during perioperative period. During surgery and in the postoperative period, random blood sugar and human insulin requirement are significantly higher in control group than glargine group. Other infection, step-up antibiotics, intensive care unit (ICU) stay, and hospital stay were significantly higher in control groups in postoperative period. Our study results suggest that glargine effectively manages blood glucose level with significantly greater control over postoperative morbidity.
Quirós, Carmen; Patrascioiu, Ioana; Giménez, Marga; Vinagre, Irene; Vidal, Mercè; Jansà, Margarita; Conget, Ignacio
2014-01-01
Patients with type 1 diabetes (T1DM) treated with continuous subcutaneous insulin infusion (CSII) have available several specific features of these devices. The aim of this study was to evaluate the relationship between real use of them and the degree of glycemic control in patients using this therapy. Forty-four T1DM patients on CSII therapy with or without real-time continuous glucose monitoring (CGM) were included. Data from 14 consecutive days were retrospectively collected using the therapy management software CareLink Personal/Pro(®) and HbA1c measurement performed at that period. The relationship between the frequency of usie of specific features of insulin pumps (non-sensor augmented or sensor-augmented) and glycemic control was analyzed. Mean HbA1c in the group was 7.5 ± .8%. Mean daily number of boluses administered was 5.1 ± 1.8, with 75.4% of them being bolus wizards (BW). Daily number of boluses was significantly greater in patients with HbA1c <7.5% than in those with HbA1c>7.5% (5.3 ± 1.6 vs. 4.3 ± 1.6, P=.056). There was a trend to greater use of BW in patients with better control (82.8 ± 21.4% vs. 69.9 ± 29.1%, P=.106). HbA1c was lower in patients using CGM (n=8) as compared to those not using sensor-augmented pumps (7.6 ± .8 vs 7.1 ± .7, P=.067), but the difference was not statistically significant. More frequent use of BW appears to be associated to better metabolic control in patients with T1DM using pump therapy. In standard clinical practice, augmentation of insulin pump with CGM may be associated to improved glycemic control. Copyright © 2013 SEEN. Published by Elsevier Espana. All rights reserved.
NASA Technical Reports Server (NTRS)
Dankanich, John W.; Swiatek, Michael W.; Yim, John T.
2012-01-01
The electric propulsion community has been implored to establish and implement a set of universally applicable test standards during the research, development, and qualification of electric propulsion systems. Existing practices are fallible and result in testing variations which leads to suspicious results, large margins in application, or aversion to mission infusion. Performance measurements and life testing under appropriate conditions can be costly and lengthy. Measurement practices must be consistent, accurate, and repeatable. Additionally, the measurements must be universally transportable across facilities throughout the development, qualification, spacecraft integration and on-orbit performance. A preliminary step to progress towards universally applicable testing standards is outlined for facility pressure measurements and effective pumping speed calculations. The standard has been applied to multiple facilities at the NASA Glenn Research Center. Test results and analyses of universality of measurements are presented herein.
Haidar, Ahmad; Legault, Laurent; Messier, Virginie; Mitre, Tina Maria; Leroux, Catherine; Rabasa-Lhoret, Rémi
2015-01-01
The artificial pancreas is an emerging technology for the treatment of type 1 diabetes and two configurations have been proposed: single-hormone (insulin alone) and dual-hormone (insulin and glucagon). We aimed to delineate the usefulness of glucagon in the artificial pancreas system. We did a randomised crossover trial of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy (continuous subcutaneous insulin infusion) in participants aged 12 years or older with type 1 diabetes. Participants were assigned in a 1:1:1:1:1:1 ratio with blocked randomisation to the three interventions and attended a research facility for three 24-h study visits. During visits when the patient used the single-hormone artificial pancreas, insulin was delivered based on glucose sensor readings and a predictive dosing algorithm. During dual-hormone artificial pancreas visits, glucagon was also delivered during low or falling glucose. During conventional insulin pump therapy visits, patients received continuous subcutaneous insulin infusion. The study was not masked. The primary outcome was the time for which plasma glucose concentrations were in the target range (4·0-10·0 mmol/L for 2 h postprandially and 4·0-8·0 mmol/L otherwise). Hypoglycaemic events were defined as plasma glucose concentration of less than 3·3 mmol/L with symptoms or less than 3·0 mmol/L irrespective of symptoms. Analysis was by modified intention to treat, in which we included data for all patients who completed at least two visits. A p value of less than 0·0167 (0·05/3) was regarded as significant. This trial is registered with ClinicalTrials.gov, number NCT01754337. The mean proportion of time spent in the plasma glucose target range over 24 h was 62% (SD 18), 63% (18), and 51% (19) with single-hormone artificial pancreas, dual-hormone artificial pancreas, and conventional insulin pump therapy, respectively. The mean difference in time spent in the target range between single-hormone artificial pancreas and conventional insulin pump therapy was 11% (17; p=0·002) and between dual-hormone artificial pancreas and conventional insulin pump therapy was 12% (21; p=0·00011). There was no difference (15; p=0·75) in the proportion of time spent in the target range between the single-hormone and dual-hormone artificial pancreas systems. There were 52 hypoglycaemic events with conventional insulin pump therapy (12 of which were symptomatic), 13 with the single-hormone artificial pancreas (five of which were symptomatic), and nine with the dual-hormone artificial pancreas (0 of which were symptomatic); the number of nocturnal hypoglycaemic events was 13 (0 symptomatic), 0, and 0, respectively. Single-hormone and dual-hormone artificial pancreas systems both provided better glycaemic control than did conventional insulin pump therapy. The single-hormone artificial pancreas might be sufficient for hypoglycaemia-free overnight glycaemic control. Canadian Diabetes Association; Fondation J A De Sève; Juvenile Diabetes Research Foundation; and Medtronic. Copyright © 2015 Elsevier Ltd. All rights reserved.
Subcutaneous immunoglobulin replacement therapy: the European experience.
Chapel, Helen; Gardulf, Ann
2013-12-01
Rapid subcutaneous immunoglobulin (SCIg) infusions have been used as an important method of delivering replacement immunoglobulin (Ig) to patients with primary immune deficiencies (PIDs) in Europe over the last 25 years. This review provides a comprehensive interpretation of the literature relating to the administration of SCIg and the services that have been developed alongside. Using rates of at least 20 ml/h per infusion site and simultaneous sites, the infusion time once per week is short (1-2 h in adults) and using small portable pumps, the child or adult is free for other activities during the therapy. The rapid SCIg infusions have been documented as well tolerated, efficacious and acceptable to infants and their parents, children, adults and elderly patients, and more recently to patients with autoimmunity requiring immunomodulatory Ig doses. As part of PID diagnostic and management services, educational programmes for self-infusion of both intravenous Ig and SCIg at home have been developed throughout Europe, resulting in increased patient compliance and patient empowerment as well as cost-savings for healthcare providers.
Hautier-Suply, Olivia; Friedmann, Yasmin; Shapley, Julian
2018-04-01
Technological advances have led to innovative insulin delivery systems for patients with type 1 diabetes mellitus. In particular, the combination of miniature engineering and software algorithms contained in continuous subcutaneous insulin infusion (CSII) system pumps provide the user and the healthcare practitioner with an opportunity to review and adjust blood glucose (BG) levels according to system feedback, and to modify or programme their regimen according to their needs. While CSII pumps record a number of data parameters such as BG level, carbohydrate intake, activity and insulin delivered, these data are generally 'locked in' and can only be accessed by uploading to a cloud-based system, thus information is not contemporaneous. The Cellnovo Diabetes Management System (Cellnovo, Bridgend, UK) allows data to be transmitted securely and wirelessly in real time to a secure server, which is then retrieved by an online platform, the Cellnovo Online platform, enabling continuous access by the user and by clinicians. In this article, the authors describe a retrospective review of the patient data automatically uploaded to the Cellnovo Online platform. Baseline clinical and demographic characteristics collected at the start of pump therapy are shown for all patients, and BG data from a sub-cohort of patients who have been using the system for at least 6 months and who take and record an average of three BG level tests per day are presented to demonstrate glycaemic data over time.
Sajadi, Ahmadali; Provost, Chloé; Pham, Brendon; Brouillette, Jonathan
2016-01-01
Decline in hippocampal-dependent explicit memory (memory for facts and events) is one of the earliest clinical symptom of Alzheimer's disease (AD). It is well established that synapse loss and ensuing neurodegeneration are the best predictors for memory impairments in AD. Latest studies have emphasized the neurotoxic role of soluble amyloid-beta oligomers (Aβo) that begin to accumulate in the human brain approximately 10 to 15 yr before the clinical symptoms become apparent. Many reports indicate that soluble Aβo correlate with memory deficits in AD models and humans. The Aβo-induced neurodegeneration observed in neuronal and brain slice cultures has been more challenging to reproduce in many animal models. The model of repeated Aβo infusions shown here overcome this issue and allow addressing two key domains for developing new disease modifying therapies: identify biological markers to diagnose early AD, and determine the molecular mechanisms underpinning Aβo-induced memory deficits at the onset of AD. Since soluble Aβo aggregate relatively fast into insoluble Aβ fibrils that correlate poorly with the clinical state of patients, soluble Aβo are prepared freshly and injected once per day during six days to produce marked cell death in the hippocampus. We used cannula specially design for simultaneous infusions of Aβo and continuous infusion of Aβo antibody (6E10) in the hippocampus using osmotic pumps. This innovative in vivo method can now be used in preclinical studies to validate the efficiency of new AD therapies that might prevent the deposition and neurotoxicity of Aβo in pre-dementia patients. PMID:27585306
Zhou, Yangning; He, Miao; Zou, Tianxiao; Yu, Bin
2015-01-01
To investigate the morphological changes in various tissues of rabbits receiving sciatic nerve block with 0.2% ropivacaine for 48 h. Twenty healthy were randomly assigned to normal saline group (N group) and ropivacaine group (R group). The right sciatic nerve was exposed, and a nerve-blocking trocar cannula embedded. Animals received an injection of 0.5% ropivacaine hydrochloride at a dose of 0.75 ml/kg. Rabbit was then connected to an infusion pump containing 50 ml of normal saline in N group, or to a infusion pump containing 0.2% ropivacaine hydrochloride in R group at 0.25 ml/kg•h-1. In both R group and N group, a small number of nerve cells exhibited pyknotic degeneration. More nerve cells with pyknotic degeneration were found in R group than in N group (P<0.001). At 48 h after surgery, there was a significant correlation between the abnormality of right hind limb and the degree of edema in sciatic nerve (P<0.01). Pyknotic degeneration of sciatic nerve increased after an infusion of 0.2% ropivacaine hydrochloride for 48 h, suggesting the neurotoxicity of ropivacaine. An infusion of 0.2% ropivacaine hydrochloride for 48 h may cause necrosis of skeletal muscle cells. The sciatic nerve edema would greatly affect the hindlimb motor while both pyknotic degeneration of sciatic nerve and skeletal muscle have little influence on the hindlimb movement. After an infusion of 0.2% ropivacaine hydrochloride for 48 h, the morphology of right atrium and brain tissues around the ventriculus tertius and medulla oblongata remained unchanged.
Manso Melgosa, Ana Belén; García Gutiérrez, Helena; Fernández Porras, Mónica; Castrillo Manero, Ana Berta; Pérez Marijuán, Belén
To describe the incidence and complications arising in a number of cases of patients with cerebrospinal fluid leak treated by external lumbar drainage with infusion pump (IP) volumetric continuous from 2001 to 2014. Quantify cerebrospinal fluid leak closed by lumbar drainage with IP. Retrospective descriptive case series study. patients undergoing transsphenoidal pituitary surgery, Chiari surgery and laminectomy, that developed postoperative cerebrospinal fluid leak treated with continuous external lumbar drainage by IP. age, sex, type of intervention, variables related to the practice of the pump and complications. Average and medians were calculated for quantitative variables, frequencies and percentages for qualitative. Sample: 11 subjects. Incidence in running IP: disconnection, occlusion and acoustic alarm activation. Most frequently complication is headache; a case of pneumocephalus. The small number of subjects and the heterogeneity of these do not allow for comparison or establishing associations between variables. The resolution of the cerebrospinal fluid leak with continuous IP is lower in this study than others, and may be influenced by the small number of subjects. It should be noted the frequent activation of the pump alarm for no apparent cause. Protocol would be developed for preparing the IP team to reduce the acoustic alarm activation, and would make a prospective multicenter study. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
The mixed blessings of smart infusion devices and health care IT.
Nemeth, Christopher P; Brown, Jeff; Crandall, Beth; Fallon, Corey
2014-08-01
From July to October 2009, a team of human factors researchers evaluated the use of a commercially available infusion device among nurses at a tertiary care hospital in the Midwest. The study's purpose was to determine the factors that may influence the adoption and "best practice" use of smart infusion devices by identifying the human, technological, environmental, and/or organizational factors and to describe how they support or impede safe practices. The study's aim was to show how technology and individual and team behavior influence each other, as well as care performance and outcomes. Research team members shadowed nursing personnel as they performed routine care activities, and conducted cognitive task analysis interviews with nurses, an engineer, and a pharmacist. They identified key themes, and then made several systematic passes through the data to identify all instances of each theme and to collect examples and illustrative quotes. Although staff members were positive in their comments about the smart pump, observations and interviews revealed discrepancies between prescriptions and infusions, and "workarounds" to cope with the mismatch between interface design and actual care requirements. Despite "smart pump" capabilities, situations continue such as the need for clinicians to perform calculations in order to deliver medications. These workarounds, which make them and patients vulnerable to adverse outcomes, confirm prior published research by Cook, Nemeth, Nunnally, Hollnagel, and Woods. The team provided recommendations based on findings for training and interface design. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.
An intra-cerebral drug delivery system for freely moving animals.
Spieth, Sven; Schumacher, Axel; Holtzman, Tahl; Rich, P Dylan; Theobald, David E; Dalley, Jeffrey W; Nouna, Rachid; Messner, Stephan; Zengerle, Roland
2012-10-01
Microinfusions of drugs directly into the central nervous system of awake animals represent a widely used means of unravelling brain functions related to behaviour. However, current approaches generally use tethered liquid infusion systems and a syringe pump to deliver drugs into the brain, which often interfere with behaviour. We address this shortfall with a miniaturised electronically-controlled drug delivery system (20 × 17.5 × 5 mm³) designed to be skull-mounted in rats. The device features a micropump connected to two 8-mm-long silicon microprobes with a cross section of 250 × 250 μm² and integrated fluid microchannels. Using an external electronic control unit, the device allows infusion of 16 metered doses (0.25 μL each, 8 per silicon shaft). Each dosage requires 3.375 Ws of electrical power making the device additionally compatible with state-of-the-art wireless headstages. A dosage precision of 0.25 ± 0.01 μL was determined in vitro before in vivo tests were carried out in awake rats. No passive leakage from the loaded devices into the brain could be detected using methylene blue dye. Finally, the device was used to investigate the effects of the NMDA-receptor antagonist 3-((R)-2-Carboxypiperazin-4-yl)-propyl-1-phosphonic acid, (R)-CPP, administered directly into the prefrontal cortex of rats during performance on a task to assess visual attention and impulsivity. In agreement with previous findings using conventional tethered infusion systems, acute (R)-CPP administration produced a marked increase in impulsivity.
Yavuz, Y C; Selcuk, N Y; Altıntepe, L; Güney, I; Yavuz, S
2018-01-01
In chronic hemodialysis patients, the low flow of vascular access may leads to inadequate dialysis, increased rate of hospitalization, morbidity, and mortality. It was found that surveillance should be performed for native arteriovenous (AV) should not be performed for AV graft in various studies. However, surveillance was done in graft AV fistulas in most studies. Doppler ultrasonography (US) was suggested for surveillance of AV fistulas by the last vascular access guideline of National Kidney Foundation Disease Outcomes Quality Initiative (NKF KDOQI). The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by pump and was measured at basal before the infusion and 11 s after the start of the infusion by glucometer. Doppler US was done by an expert radiologist. Used statistical tests were Mann-Whitney U test, Friedman test, regression analysis, and multiple regression analysis. Median values of blood flow rates measured by GPT (707 mL/min) and by Doppler US (700 mL/min) were not different (Z = 0.414, P = 0.678). Results of GPT and Doppler US measurements were positive correlate by regression analysis. The mean GPT value of diabetic patients (n = 39; 908 mL/min) was similar to that of nondiabetic patients (n = 54; 751 mL/min; Z = 1.31, P = 0.188). GPT values measured at three different dialysis session did not differ from each other that by Friedman test (F = 0.92, P = 0.39). This showed that GPT was stable and reliable. Glucose pump test can be used to measure blood flow rate of native AV fistula. GPT is an accurate and reliable test.
Evaluation of CGP 39393 as the anticoagulant in cardiopulmonary bypass operation in a dog model.
Walenga, J M; Koza, M J; Park, S J; Terrell, M R; Pifarré, R
1994-12-01
Recombinant desulphatohirudin HV1 (CGP 39393), a specific and potent peptidic inhibitor of thrombin, was evaluated as the sole anticoagulant in a dog model of cardiopulmonary bypass. CGP 39393 was administered as a bolus plus infusion for a 1-hour pump period at doses of 1.0 mg/kg + 0.75 mg.kg-1.h-1, 1.0 mg/kg + 1.50 mg.kg-1.h-1, 1.0 mg/kg + 2.25 mg.kg-1.h-1, or 1.0 mg/kg + 3.0 mg.kg-1.h-1 (n = 5 per group). The lowest dose was ineffective, as a high degree of clot formation (314 +/- 160 mg) occurred as determined by quantitation of protein deposits in the pump line filter. The three higher doses inhibited clot formation (35 to 44 mg) but did not reveal a dose-dependent effect (p = 0.308 between groups). All four doses produced the same amount of postoperative blood loss (6.5 to 10 g/kg over 2 hours; p = 0.215 between groups) and no oozing of blood from cut tissues (sternum, muscle, skin) during or after operation. No adverse hemodynamic or hematologic effects were observed. Animals were physiologically stable coming off pump, requiring minimal fluid replacement or other cardiovascular supportive measures. The chromogenic anti-IIa assay could be used to monitor CGP 39393. Some activated partial thromboplastin time and all activated clotting time values were off scale on pump, but they fell immediately after cardiopulmonary bypass, typically reaching near-normal levels within 30 to 60 minutes. No reversal of CGP 39393 was used, as blood levels declined rapidly after cessation of the infusion. This study in a dog model shows that CGP 39393 administered as a bolus plus infusion (minimum dose, 1.0 mg/kg + 1.50 mg.kg-1.h-1) can be used safely and effectively during cardiopulmonary bypass for cardiac operation.
[Usefulness of Bolus Administration Using the FLEX Mode(Bolus Infusion Mode)for Baclofen Tolerance].
Tanaka, Kazunori
2017-02-01
Intrathecal baclofen(ITB)is used to treat intractable spasticity of various etiologies and can provide better control of spasticity through the adjustment of the dose administered through the pump. However, in patients who develop tolerance to baclofen with the standard simple continuous mode, a sharp increase in dose becomes necessary, and spasticity can become harder to control. We investigated whether switching from the simple continuous mode to the bolus infusion mode was effective in controlling spasticity in patients with baclofen tolerance. We reported four patients undergoing ITB therapy at our facility who were considered to have developed baclofen tolerance. We observed the number of bolus infusions and total dose suitable for maintaining spasticity control after switching from the simple continuous mode to the bolus infusion mode. After switching to the bolus infusion mode, the total dose could be reduced in the short term; however, in the long term, the frequency of bolus infusions had to be increased to maintain spasticity control. Two years after changing to bolus infusion six times a day, the total dose was higher than that in the simple continuous mode for two of the four patients, and was the same level in the other two patients. Our four cases suggest that bolus infusion is effective in patients with baclofen tolerance during ITB therapy. Therefore, the conditions of bolus infusion should be further investigated.
[Ziconotide: an innovative alternative for intense chronic neuropathic pain].
Valía-Vera, J C; Villanueva, V L; Asensio-Samper, J M; López-Alarcón, M D; de Andrés, J A
Intense chronic pain is a very important health problem, as it has a high prevalence (5-10%), a multifactorial aetiology and its management is very often a very complex affair. Treatment of severe cases sometimes requires interventional approaches, such as continuous intrathecal infusion of opioids. We report the case of a 38-year-old female with intense neuropathic pain in the lower back and the lower limbs secondary to three operations on the L5-S1 lumbar segment. After implementing several different pharmacological regimes involving both oral and implanted systems (spinal cord stimulation and subarachnoid infusion pump with different pharmacological combinations) with no clinical improvement, intrathecal infusion with ziconotide was included in the protocol. Ziconotide is the first specific neuronal blocker that acts on the calcium channel by blocking the N-type voltage-dependent calcium channels. It is a new non-opioid analgesic with approved indication in the treatment of intense chronic pain, in patients who require intrathecal analgesics and are refractory to other analgesic treatments. Therefore, we shall have to consider this drug as a therapeutic alternative in patients do not experience sufficient relief with the pharmacological agents and means currently available to treat them.
Pozzilli, Paolo; Battelino, Tadej; Danne, Thomas; Hovorka, Roman; Jarosz-Chobot, Przemyslawa; Renard, Eric
2016-01-01
The level of glycaemic control necessary to achieve optimal short-term and long-term outcomes in subjects with type 1 diabetes mellitus (T1DM) typically requires intensified insulin therapy using multiple daily injections or continuous subcutaneous insulin infusion. For continuous subcutaneous insulin infusion, the insulins of choice are the rapid-acting insulin analogues, insulin aspart, insulin lispro and insulin glulisine. The advantages of continuous subcutaneous insulin infusion over multiple daily injections in adult and paediatric populations with T1DM include superior glycaemic control, lower insulin requirements and better health-related quality of life/patient satisfaction. An association between continuous subcutaneous insulin infusion and reduced hypoglycaemic risk is more consistent in children/adolescents than in adults. The use of continuous subcutaneous insulin infusion is widely recommended in both adult and paediatric T1DM populations but is limited in pregnant patients and those with type 2 diabetes mellitus. All available rapid-acting insulin analogues are approved for use in adult, paediatric and pregnant populations. However, minimum patient age varies (insulin lispro: no minimum; insulin aspart: ≥2 years; insulin glulisine: ≥6 years) and experience in pregnancy ranges from extensive (insulin aspart, insulin lispro) to limited (insulin glulisine). Although more expensive than multiple daily injections, continuous subcutaneous insulin infusion is cost-effective in selected patient groups. This comprehensive review focuses on the European situation and summarises evidence for the efficacy and safety of continuous subcutaneous insulin infusion, particularly when used with rapid-acting insulin analogues, in adult, paediatric and pregnant populations. The review also discusses relevant European guidelines; reviews issues that surround use of this technology; summarises the effects of continuous subcutaneous insulin infusion on patients' health-related quality of life; reviews relevant pharmacoeconomic data; and discusses recent advances in pump technology, including the development of closed-loop 'artificial pancreas' systems. © 2015 The Authors. Diabetes/Metabolism Research and Reviews Published by John Wiley & Sons Ltd. © 2015 The Authors. Diabetes/Metabolism Research and Reviews Published by John Wiley & Sons Ltd.
Delivered volumes of enteral nutrition exceed prescribed volumes.
Walker, Renee Nichole; Utech, Anne; Velez, Maria Eugenia; Schwartz, Katie
2014-10-01
Enteral nutrition (EN) provisions are typically calculated based on a 24-hour infusion period. However, feedings are often interrupted for daily activities, procedures, or gastrointestinal intolerance. The study's objective was to determine the delivered EN quantities provided to stable hospitalized patients, using cellular time and measured volumes to verify our EN calculation adjustment. A supply of consecutively numbered ready-to-hang (RTH) EN product was delivered to the bedside of 26 inpatients with established EN tolerance at goal rates on various types of nursing units. The dietitian weighed the volume remaining in the infusing product and recorded the measurement time. On the following days, the dietitian continued to weigh the infusing RTH product and the empty RTH bottles saved by nursing. The primary outcome was the difference between the prescribed and delivered EN provisions, which was calculated with a paired t test. Patients received significantly more calories in the delivered enteral feeding (mean [SD], 1678 [385] kcal) than prescribed calories in the EN order (1489 [246 kcal]; t = 3.736, P = .001), adjusting for observed time. No significant differences were found between nursing units, product, and rate. EN delivered may actually exceed ordered amounts by 5%–21% (mean, 12%) with feeding pump inaccuracy as the primary contributing factor. This differs from what others have found. Our findings support using a volume-based ordering system vs a rate-based ordering system for more accurate EN delivery.
Use of case-based reasoning to enhance intensive management of patients on insulin pump therapy.
Schwartz, Frank L; Shubrook, Jay H; Marling, Cynthia R
2008-07-01
This study was conducted to develop case-based decision support software to improve glucose control in patients with type 1 diabetes mellitus (T1DM) on insulin pump therapy. While the benefits of good glucose control are well known, achieving and maintaining good glucose control remains a difficult task. Case-based decision support software may assist by recalling past problems in glucose control and their associated therapeutic adjustments. Twenty patients with T1DM on insulin pumps were enrolled in a 6-week study. Subjects performed self-glucose monitoring and provided daily logs via the Internet, tracking insulin dosages, work, sleep, exercise, meals, stress, illness, menstrual cycles, infusion set changes, pump problems, hypoglycemic episodes, and other events. Subjects wore a continuous glucose monitoring system at weeks 1, 3, and 6. Clinical data were interpreted by physicians, who explained the relationship between life events and observed glucose patterns as well as treatment rationales to knowledge engineers. Knowledge engineers built a prototypical system that contained cases of problems in glucose control together with their associated solutions. Twelve patients completed the study. Fifty cases of clinical problems and solutions were developed and stored in a case base. The prototypical system detected 12 distinct types of clinical problems. It displayed the stored problems that are most similar to the problems detected, and offered learned solutions as decision support to the physician. This software can screen large volumes of clinical data and glucose levels from patients with T1DM, identify clinical problems, and offer solutions. It has potential application in managing all forms of diabetes.
Uslusoy, Esin; Mete, Samiye
2008-04-01
The purpose of this study was to investigate the predisposing factors in the development of phlebitis in peripheral intravenous (IV) catheterization sites in patients treated with a variety of IV infusion solutions and drugs. Systematic observation of 568 IV sites inserted for fluid infusion and drug administration in 355 patients in the Department of General Surgery of a University Hospital in Turkey. A data collection tool was based on standards established by the Infusion Nurses Society. Patients' infusion sites were monitored every 24 h during treatment and for 48 h after discontinuation of the IV. In contrast to the usual findings in the literature, the authors found that infusion through an infusion pump and insertion of catheters in the veins around the elbow increased the risk of phlebitis. Also, the number of times infusions were started led to an increased rate of phlebitis. However, conflicting results were obtained about the relation between phlebitis, gender, and catheter size. Phlebitis causes sepsis, pain, additional diagnostic investigations, and treatments, and may lead to increased duration of hospitalization, patient's stress level, and financial burden, as well as increasing staff workload. Advanced practice nurses need to be aware of the factors that increase the likelihood of phlebitis and take appropriate measures to prevent it.
Long-term stability of 5-fluorouracil stored in PVC bags and in ambulatory pump reservoirs.
Martel, P; Petit, I; Pinguet, F; Poujol, S; Astre, C; Fabbro, M
1996-02-01
Prolonged infusions of 5-fluorouracil (5FU) have been used since the early 1960s, but recently there has been a major resurgence of interest, partly because of the advent of electronically controlled portable infusion pumps. Admixtures of new formulation 5FU were subjected to stability studies to establish the feasability of continuous infusions. In the first study, the stability of 5FU, 1 or 10 mg ml(-1), was determined in poly(vinyl chloride) (PVC) bags (0.9% sodium chloride injection or 5% dextrose injection) at 4 and 21 degrees C after storage for 0, 1, 2, 3, 4, 7 and 14 days. In the second study, the stability of undiluted 5FU was tested at different temperatures (4 or 33 degrees C) in ethylene-vinyl acetate (EVA) or PVC ambulatory pump reservoirs after storage for 0, 3, 5, 7 and 14 days. For each condition, samples from each admixture were tested for drug concentration by stability-indicating high-performance liquid chromatography. The admixtures were also monitored for precipitation, colour change and pH. Evaporative water loss from the containers was measured. The stability of 5FU in PVC bags was unaffected by 14 days of storage at either 4 or 21 degrees C. When stored in EVA reservoirs, 5FU was stable for at least 2 weeks at 33 degrees C and for 3 days at 4 degrees C (a precipitate was observed after 3 days). In PVC reservoirs, 5FU was stable for over 14 days at 33 degrees C, but at 4 degrees C a precipitate appeared after 5 days. Loss of water through the reservoirs was substantial only at 33 degrees C for 14 days, and gave falsely high readings.
Continuous subcutaneous insulin infusion therapy for Type 1 diabetes mellitus in children.
Mavinkurve, M; Quinn, A; O'Gorman, C S
2016-05-01
Continuous subcutaneous insulin pump therapy (CSII or pump therapy) is a well-recognised treatment option for Type 1 diabetes mellitus (T1DM) in paediatrics. It is especially suited to children because it optimises control by improving flexibility across age-specific lifestyles. The NICE guidelines (2008) recognise that pump therapy is advantageous and that it should be utilised to deliver best practice. In Ireland, the National Clinical Program for Diabetes will increase the availability and uptake of CSII in children and thus more clinicians are likely to encounter children using CSII therapy. This is a narrative review which discusses the basic principles of pump therapy and focuses on aspects of practical management. Insulin pump management involves some basic yet important principles which optimise the care of diabetes in children. This review addresses the principles of insulin pump management in children which all health care professionals involved in caring for the child with diabetes, shoud be familiar with.
Park, Sunmin; Ahn, Il Sung; Kim, Da Sol
2010-06-05
We investigated whether hypothalamic leptin alters beta-cell function and mass directly via the sympathetic nervous system (SNS) or indirectly as the result of altered insulin resistant states. The 90% pancreatectomized male Sprague Dawley rats had sympathectomy into the pancreas by applying phenol into the descending aorta (SNSX) or its sham operation (Sham). Each group was divided into two sections, receiving either leptin at 300ng/kgbw/h or artificial cerebrospinal fluid (aCSF) via intracerebroventricular (ICV) infusion for 3h as a short-term study. After finishing the infusion study, ICV leptin (3mug/kg bw/day) or ICV aCSF (control) was infused in rats fed 30 energy % fat diets by osmotic pump for 4weeks. At the end of the long-term study, glucose-stimulated insulin secretion and islet morphometry were analyzed. Acute ICV leptin administration in Sham rats, but not in SNSX rats, suppressed the first- and second-phase insulin secretion at hyperglycemic clamp by about 48% compared to the control. Regardless of SNSX, the 4-week administration of ICV leptin improved glucose tolerance during oral glucose tolerance tests and insulin sensitivity at hyperglycemic clamp, compared to the control, while it suppressed second-phase insulin secretion in Sham rats but not in SNSX rats. However, the pancreatic beta-cell area and mass were not affected by leptin and SNSX, though ICV leptin decreased individual beta-cell size and concomitantly increased beta-cell apoptosis in Sham rats. Leptin directly decreases insulin secretion capacity mainly through the activation of SNS without modulating pancreatic beta-cell mass.
Vented spikes improve delivery from intravenous bags with no air headspace.
Galush, William J; Horst, Travis A
2015-07-01
Flexible plastic bags are the container of choice for most intravenous (i.v.) infusions. Under certain circumstances, however, the air-liquid interface present in these i.v. bags can lead to physical instability of protein biopharmaceuticals, resulting in product aggregation. In principle, the air headspace present in the bags can be removed to increase drug stability, but experiments described here show that this can result in incomplete draining of solution from the bag using gravity delivery, or generation of negative pressure in the bag when an infusion pump is used. It is expected that these issues could lead to incomplete delivery of medication to patients or pump-related problems, respectively. However, here it is shown that contrary to the standard pharmacy practice of using nonvented spikes with i.v. bags, the use of vented spikes with i.v. bags that lack air headspace allows complete delivery of the dose solution without impacting the physical stability of a protein-based drug. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
Strategies for Managing Smart Pump Alarm and Alert Fatigue: A Narrative Review.
Shah, Parth K; Irizarry, Jamie; O'Neill, Sean
2018-06-08
Although smart infusion pumps are intended to prevent medication errors by alerting users about doses that exceed set thresholds, a large number of clinically insignificant alarms and alerts create the potential for alert and alarm fatigue. We searched the PubMed, Scopus, and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases for peer-reviewed literature (January 1, 2004-August 31, 2017) on managing smart pump alerts, alarms, and related fatigue. Twenty-nine articles that met the inclusion criteria were reviewed and organized into themes. Smart pumps give users two types of signals: alarms that indicate mechanical issues such as occlusion, air in the line, or low battery; and clinical alerts that indicate that a programmed dose exceeds a predefined safety limit. Mechanical alarms occur with greater frequency than clinical alerts, but alarms and alerts vary widely by pump model, patient population, time of day, month, and type of drug. Several causes of clinically insignificant alerts and alarms may be actionable, and strategies proposed in the literature include development of a multidisciplinary team to oversee the quality improvement effort with involvement of end users, standardization of medication administration practices, widening of drug limit library thresholds when clinically appropriate, maintaining up-to-date drug limit libraries, and interoperability. Whereas many strategies have been proposed, and case studies have been reported, none have been rigorously evaluated. In addition, more research is needed related to managing occlusion and air-in-line alarms, especially for complicated infusions. Future work should focus on the evaluation of specific and replicable alert and alarm reduction strategies with a greater emphasis on quantitative metrics. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Tchekalarova, Jane; Ivanova, Natasha; Pechlivanova, Daniela; Ilieva, Kalina; Atanasova, Milena
2014-01-01
We studied the involvement of angiotensin (Ang) II AT1 receptors in the pathophysiology of kainate (KA)-induced neurotoxicity, focusing on the regulation of the oxidative stress state and expression of HSP 72 in the frontal cortex and hippocampus in two strains, spontaneously hypertensive rats (SHRs) and normotensive Wistar rats. The KA injection was executed after the rats were infused subcutaneously via osmotic mini-pumps with losartan (10 mg/kg day) for 14 days. Losartan delayed the onset of KA-induced seizures in SHRs but not in Wistar rats without affecting the seizure intensity score. This selective AT1 receptor antagonist decreased the lipid peroxidation only in naive SHRs. However, it attenuated the KA-induced increase in lipid peroxidation in both SHRs and Wistar rats. The adaptive enhancement of cytosolic superoxide dismutase (SOD) activity in KA-treated SHRs was recovered to control level after sub-chronic losartan infusion while no change in mitochondrial SOD activity was detected in the two strains. Both losartan and KA produced a higher expression of HSP 72 in the hippocampus of the two strains compared to naive rats infused with vehicle. Taken together, our findings demonstrate that the efficacy of a sub-chronic systemic losartan infusion in preventing the KA-induced seizure activity and neurotoxicity is more pronounced in SHRs, considered as a model of essential hypertension, than in normotenisve Wistar rats. The results suggest that the blockade of AT1 receptors, commonly used as a strategy for prevention of high blood pressure, may be useful as an adjunctive treatment in status epilepticus to reduce oxidative stress and neurotoxicity.
KAYA, MEHMET; GREGORY, THOMAS S.; DAYTON, PAUL A.
2009-01-01
Stabilized microbubbles are utilized as ultrasound contrast agents. These micron-sized gas capsules are injected into the bloodstream to provide contrast enhancement during ultrasound imaging. Some contrast imaging strategies, such as destruction-reperfusion, require a continuous injection of microbubbles over several minutes. Most quantitative imaging strategies rely on the ability to administer a consistent dose of contrast agent. Because of the buoyancy of these gas-filled agents, their spatial distribution within a syringe changes over time. The population of microbubbles that is pumped from a horizontal syringe outlet differs from initial population as the microbubbles float to the syringe top. In this manuscript, we study the changes in the population of a contrast agent that is pumped from a syringe due to microbubble floatation. Results are presented in terms of change in concentration and change in mean diameter, as a function of time, suspension medium, and syringe diameter. Data illustrate that the distribution of contrast agents injected from a syringe changes in both concentration and mean diameter over several minutes without mixing. We discuss the application of a mixing system and viscosity agents to keep the contrast solution more evenly distributed in a syringe. These results are significant for researchers utilizing microbubble contrast agents in continuous-infusion applications where it is important to maintain consistent contrast agent delivery rate, or in situations where the injection syringe cannot be mixed immediately prior to administration. PMID:19632760
A sophisticated programmable miniaturised pump for insulin delivery.
Klein, J C; Slama, G
1980-09-01
We have conceived a truly pre-programmable infusion system usable for intravenous administration of insulin in diabetic subjects. The original system has been built into a small, commercially available, syringe-pump of which only the case and the mechanical parts have been kept. The computing until has a timer, a programmable memory of 512 words by 8 bits and a digital-to-frequency converter to run the motor which drives the syringe. The memory contains 8 profiles of insulin injections stored in digital form over 64 words. Each profile is selected by the patient before eating according to the carbohydrate content of the planned meal and last about two hours, starting from and returning to the basal rate of insulin, at which it remains until next profile selection. Amount, profiles and duration of insulin injection are either mean values deduced from previous studies with a closed-loop artificial pancreas or personally fitted values; they are stored in an instantly replaceable memory cell. This device allows the patient to choose the time, nature and amount of his food intake.
The effect of lithium on electrolyte transport by the in situ choroid plexus of the cat.
Reed, D J; Yen, M H
1980-01-01
1. The effects of lithium on electrolyte transport were studied by using the cat choroid plexus isolated in a chamber in situ. 2. Lithium infused intravenously to produce plasma lithium concentrations up to 5 m-equiv/l. caused an increase in plasma magnesium with no effect on the concentration of magnesium in the chamber fluid. 3. When 22NaCl was infused intravenously the chamber fluid/plasma ratio of 22Na was nearly 1 in the first 30 min sample and at the steady state it was significantly greater than 1. 4. When lithium chloride (1.5 m-equiv/l.) or potassium chloride (6.6 m-equiv/l.) was added to the chamber at the start of a collection period with plasma 22Na in the steady state, the 22Na content of the chamber fluid promptly increased 118 and 68%, respectively, above the control value with no increase in secretory rate. 5. The addition of ouabain to the chamber fluid, in addition to the lithium chloride or potassium chloride, tended to stimulate or have no significant effect on 22Na uptake at a concentration of 10(-5) M and to reduce it as well as the secretory rate at 10(-3) M. 6. The date are compatible with there being two functionally separate sodium transport systems in the choroid plexus. One transports sodium accompanied by an anion and water to provide the fluid secreted into the chamber (c.s.f.) and the other operates primarily to regulate the potassium concentration of the c.s.f. by pumping potassium out in exchange for sodium. 7. Lithium can be transported by both systems to a limited extent and the presence of lithium in the c.s.f. stimulates the sodium-potassium regulating pump. PMID:7252869
Miranpuri, Gurwattan; Hinchman, Angelica; Wang, Anyi; Schomberg, Dominic; Kubota, Ken; Brady, Martin; Raghavan, Raghu; Bruner, Kevin; Brodsky, Ethan; Block, Walter; Grabow, Ben; Raschke, Jim; Alexander, Andrew; Ross, Chris; Simmons, Heather; Sillay, Karl
2013-07-01
Convection enhanced delivery (CED) is emerging as a promising infusion toolto facilitate delivery of therapeutic agents into the brain via mechanically controlled pumps. Infusion protocols and catheter design have an important impact on delivery. CED is a valid alternative for systemic administration of agents in clinical trials for cell and gene therapies. Where gel and ex vivo models are not sufficient in modeling the disease, in vivo models allow researchers to better understand the underlying mechanisms of neuron degeneration, which is helpful in finding novel approaches to control the process or reverse the progression. Determining the risks, benefits, and efficacy of new gene therapies introduced via CED will pave a way to enter human clinical trial. The objective of this study is to compare volume distribution (Vd)/ volume infused (Vi) ratios and backflow measurements following CED infusions in ex vivo versus in vivo non-human primate brain tissue, based on infusion protocols developed in vitro. In ex vivo infusions, the first brain received 2 infusions using a balloon catheter at rates of 1 μL/min and 2 μL/min for 30 minutes. The second and third brains received infusions using a valve-tip (VT) catheter at 1 μL/min for 30 minutes. The fourth brain received a total of 45 μL infused at a rate of 1 μL/min for 15 minutes followed by 2 μL/min for 15 minutes. Imaging was performed (SPGR FA34) every 3 minutes. In the in vivo group, 4 subjects received a total of 8 infusions of 50 μL. Subjects 1 and 2 received infusions at 1.0 μL/min using a VT catheter in the left hemisphere and a smart-flow (SF) catheter in the right hemisphere. Subjects 3 and 4 each received 1 infusion in the left and right hemisphere at 1.0 μL/min. MRI calculations of Vd/Vi did not significantly differ from those obtained on post-mortem pathology. The mean measured Vd/Vi of in vivo (5.23 + /-1.67) compared to ex vivo (2.17 + /-1.39) demonstrated a significantly larger Vd/Vi for in vivo by 2.4 times (p = 0.0017). We detected higher ratios in the in vivo subjects than in ex vivo. This difference could be explained by the extra cellular space volume fraction. Studies evaluating backflow and morphology use in vivo tissue as a medium are recommended. Further investigation is warranted to evaluate the role blood pressure and heart rate may play in human CED clinical trials.
Karlin, Andrew W.; Ly, Trang T.; Pyle, Laura; Forlenza, Gregory P.; Messer, Laurel; Wadwa, R. Paul; DeSalvo, Daniel J.; Payne, Sydney L.; Hanes, Sarah; Clinton, Paula; Buckingham, Bruce
2016-01-01
Abstract Background: Improved insulin infusion set survival and faster insulin action are important issues for pump users and for the development of an artificial pancreas. The current recommendation is to change infusion sets every 3 days. Our objectives were to determine the effect of lipohypertrophy (LH) on infusion set survival and continuous glucose monitoring glucose levels. Research Design and Methods: In this multicenter crossover trial, we recruited 20 subjects (age 28.1 ± 9.0 years) with type 1 diabetes (duration 17.5 ± 8.8 years) and an area of lipohypertrophied tissue >3 cm. Subjects alternated weekly wearing a Teflon infusion set in an area of either LH or non-LH for 4 weeks. Sets were changed after (a) failure or (b) surviving 7 days of use. Results: The least-squares mean duration of infusion set survival for sets that lasted <7 days in lipohypertrophied tissue was 4.31 days compared with 4.12 days in nonlipohypertrophied tissue (P = 0.71). The average duration of set survival for individual subjects ranged from 2.2 to 7.0 days. Infusion sets in lipohypertrophied tissue failed due to hyperglycemia in 35% of subjects compared with 23% in nonlipohypertrophied tissue (P = 0.22). Both lipohypertrophied and nonlipohypertrophied tissues displayed a general increase in mean daily glucose after the third day of infusion set wear, but daily mean glucose did not differ by tissue type (P > 0.38 on each day). Conclusion: LH did not significantly affect infusion set survival or mean glucose. Achieving optimal infusion set performance requires research into factors affecting set survival. Additionally, the recommendation for duration of set change may need to be individualized. PMID:27227290
[Critical infusion incident caused by incorrect use of a patient-controlled analgesia pump].
Steffen, M; von Hintzenstern, U; Obermayer, A
2002-01-01
We report on the case of a 17-year-old male patient who received a PCA pump after nephrectomy for postoperative analgesia. The syringe of the PCA pump was filled with 50 mg morphine and positioned about 25 cm above the heart. Since the piston of the syringe was not bolted while the pump was switched off, an unnoticed accidental evacuation of the whole content of the syringe into the intravenous line of the patient occurred because of gravity. This problem exists not only with PCA pumps, but can happen with syringe pumps in general. The incident, which can only be explained by strongly reduced venous pressure, was detected by chance. No harm resulted for the patient, but under different conditions it could have been lethal. This critical incident was caused by various factors: incorrect application in combination with insufficient experience or training, stress, inadequate handing-over of the patient and a lack of arrangements and instructions for procedures in routine situations. Suggestions for preventing such dangerous critical incidents are made and discussed. In particular, an algorithm for the correct procedure when inserting or changing the syringe of a syringe pump is presented.
Devadasan, S. R.; Sivaram, N. M.
2015-01-01
During the recent years, the manufacturing world has been witnessing the application of agile manufacturing paradigm. The literature review reported in this paper was carried out to study this progression. This literature review was carried out in two phases. In the first phase, the literature was reviewed to trace the origin of agile manufacturing paradigm and identify its enablers. Further, during this phase, the applications of agile manufacturing reported in literature arena were reviewed. It was also discernable that certain research works have been initiated to apply agile manufacturing paradigm in pump industry. During the second phase, the researches reported on applying agile manufacturing in pump industry were reviewed. At the end of this review, it was found that so far the implementation of agile manufacturing in pump industry has been examined by the researchers by considering only certain components of pumps. In fact, the holistic implementation of agile manufacturing in the pump industry is yet to be examined by the researchers. In the context of drawing this inference, this paper has been concluded by stating that high scope exists in examining the infusing of agility characteristics in designing and manufacturing of pumps. PMID:26065016
Thilak, V M M; Devadasan, S R; Sivaram, N M
2015-01-01
During the recent years, the manufacturing world has been witnessing the application of agile manufacturing paradigm. The literature review reported in this paper was carried out to study this progression. This literature review was carried out in two phases. In the first phase, the literature was reviewed to trace the origin of agile manufacturing paradigm and identify its enablers. Further, during this phase, the applications of agile manufacturing reported in literature arena were reviewed. It was also discernable that certain research works have been initiated to apply agile manufacturing paradigm in pump industry. During the second phase, the researches reported on applying agile manufacturing in pump industry were reviewed. At the end of this review, it was found that so far the implementation of agile manufacturing in pump industry has been examined by the researchers by considering only certain components of pumps. In fact, the holistic implementation of agile manufacturing in the pump industry is yet to be examined by the researchers. In the context of drawing this inference, this paper has been concluded by stating that high scope exists in examining the infusing of agility characteristics in designing and manufacturing of pumps.
Optimizing gene transfer to conventional outflow cells in living mouse eyes
Li, G; Gonzalez, P; Camras, LJ; Navarro, I; Qiu, J; Challa, P; Stamer, WD
2013-01-01
The mouse eye has physiological and genetic advantages to study conventional outflow function. However, its small size and shallow anterior chamber presents technical challenges to efficient intracameral delivery of genetic material to conventional outflow cells. The goal of this study was to optimize methods to overcome this technical hurdle, without damaging ocular structures or compromising outflow function. Gene targeting was monitored by immunofluorescence microscopy after transduction of adenovirus encoding green fluorescent protein driven by a CMV promoter. Guided by a micromanipulator and stereomicroscope, virus was delivered intracamerally to anesthetized mice by bolus injection using 33 gauge needle attached to Hamilton syringe or infusion with glass micropipette connected to syringe pump. The total number of particles introduced remained constant, while volume of injected virus solution (3–10 µl) was varied for each method and time of infusion (3–40 min) tested. Outflow facility and intraocular pressure were monitored invasively using established techniques. Unlike bolus injections or slow infusions, introduction of virus intracamerally during rapid infusions (3 min) at any volume tested preferentially targeted trabecular meshwork and Schlemm's canal cells, with minimal transduction of neighboring cells. While infusions resulted in transient intraocular pressure spikes (commensurate with volume infused, Δ40–70 mmHg), eyes typically recovered within 60 minutes. Transduced eyes displayed normal outflow facility and tissue morphology 3–6 days after infusions. Taken together, fast infusion of virus solution in small volumes intracamerally is a novel and effective method to selectively deliver agents to conventional outflow cells in living mice. PMID:23337742
Eide, K; Stubhaug, A; Oye, I; Breivik, H
1995-05-01
The effect of continuous subcutaneous (s.c.) infusion of ketamine on nerve injury pain was examined in patients with post-herpetic neuralgia. Five patients that reported pain relief after acute intravenous injection of ketamine were included in this open prospective study. Ketamine was administered continuously in increasing doses using a portable infusion pump (CADD-PLUS, Pharmacia), and the treatment period for each infusion rate (0.05, 0.075, 0.10, or 0.15 mg/kg/h) was 7 days and nights. Relief of continuous pain, as evaluated daily by visual analogue scales, was observed at the infusion rate of 0.05 mg/kg/h, but was most marked during infusion of 0.15 mg/kg/h. All the patients reported that ketamine reduced the severity of continuous pain as well as reduced the severity and number of attacks of spontaneous pain. Changes in evoked pain (allodynia and wind-up-like pain) were recorded before change of infusion rate. Allodynia was maximally reduced 59-100% after 1 week infusion of 0.05 mg/kg/h, and wind-up-like pain was maximally reduced 60-100% after 1 week infusion of 0.15 mg/kg/h. Itching and painful indurations at the injection site was the most bothersome side-effect and for this reason 1 patient discontinued treatment after 2 weeks. Other common side-effects were nausea, fatigue and dizziness. The present results show that continuous, spontaneous and evoked pain in patients with post-herpetic neuralgia is reduced by continuous s.c. infusion of ketamine, but is associated with intolerable side effects.
Legal semantics. Nurses and non-surgical abortions.
Rae, K
1981-02-26
A 1980 law was confirmed by the House of Lords majority which allows nurses to participate in the nonsurgical prostaglandin termination of pregnancy. Nurses are acting under written instructions of a doctor when carrying out the procedure, although they also terminate the pregnancy. A nurse is now in danger of liability litigation if she fails at any stage of the termination to perform successfully. The majority decision made the two words "termination" and "treatment" of pregnancy synonymous. Nurses are to act in a ministerial capacity and on doctors' orders. Doctors are to share in any liability if negligence should occur. The question remains: will they? The procedure includes the following: attachment of the catheter to the prostaglandin pump; switching on of pump; insertion of a cannula into the vein; attachment and commencement of the oxytocin intravenous infusion; monitoring of the patient's observations; adjustment of the flow rates of both infusions; and, discontinuation of the process once the fetus is discharged or a fixed period has expired after which the operation is considered to have failed (usually 30 hours).
An implantable bolus infusion pump for use in freely moving, nontethered rats
HOLSCHNEIDER, D. P.; MAAREK, J.-M. I.; HARIMOTO, J.; YANG, J.; SCREMIN, O. U.
2014-01-01
One of the current constraints on functional neuroimaging in animals is that to avoid movement artifacts during data acquisition, subjects need to be immobilized, sedated, or anesthetized. Such measures limit the behaviors that can be examined, and introduce the additional variables of stress or anesthetic agents that may confound meaningful interpretation. This study provides a description of the design and characteristics of a self-contained, implantable microbolus infusion pump (MIP) that allows triggering of a bolus injection at a distance in conscious, behaving rats that are not restrained or tethered. The MIP is externally triggered by a pulse of infrared light and allows in vivo bolus drug delivery. We describe application of this technology to the intravenous bolus delivery of iodo[14C]antipyrine in a freely moving animal, followed immediately by lethal injection, rapid removal of the brain, and analysis of regional cerebral blood flow tissue radioactivity with the use of autoradiography. The ability to investigate changes in brain activation in nonrestrained animals makes the MIP a powerful tool for evaluation of complex behaviors. PMID:12234827
Localized infusion of IGF-I results in skeletal muscle hypertrophy in rats
NASA Technical Reports Server (NTRS)
Adams, G. R.; McCue, S. A.
1998-01-01
Insulin-like growth factor I (IGF-I) peptide levels have been shown to increase in overloaded skeletal muscles (G. R. Adams and F. Haddad. J. Appl. Physiol. 81: 2509-2516, 1996). In that study, the increase in IGF-I was found to precede measurable increases in muscle protein and was correlated with an increase in muscle DNA content. The present study was undertaken to test the hypothesis that direct IGF-I infusion would result in an increase in muscle DNA as well as in various measurements of muscle size. Either 0.9% saline or nonsystemic doses of IGF-I were infused directly into a non-weight-bearing muscle of rats, the tibialis anterior (TA), via a fenestrated catheter attached to a subcutaneous miniosmotic pump. Saline infusion had no effect on the mass, protein content, or DNA content of TA muscles. Local IGF-I infusion had no effect on body or heart weight. The absolute weight of the infused TA muscles was approximately 9% greater (P < 0.05) than that of the contralateral TA muscles. IGF-I infusion resulted in significant increases in the total protein and DNA content of TA muscles (P < 0.05). As a result of these coordinated changes, the DNA-to-protein ratio of the hypertrophied TA was similar to that of the contralateral muscles. These results suggest that IGF-I may be acting to directly stimulate processes such as protein synthesis and satellite cell proliferation, which result in skeletal muscle hypertrophy.
Xu, Xiu; Zhang, Honglei; Li, Yiming; Li, Bin
2015-07-01
Developed the information centralization and management integration system for monitors of different brands and models with wireless sensor network technologies such as wireless location and wireless communication, based on the existing wireless network. With adaptive implementation and low cost, the system which possesses the advantages of real-time, efficiency and elaboration is able to collect status and data of the monitors, locate the monitors, and provide services with web server, video server and locating server via local network. Using an intranet computer, the clinical and device management staffs can access the status and parameters of monitors. Applications of this system provide convenience and save human resource for clinical departments, as well as promote the efficiency, accuracy and elaboration for the device management. The successful achievement of this system provides solution for integrated and elaborated management of the mobile devices including ventilator and infusion pump.
Mokadem, Mohamad; Noureddine, Lama; Howard, Thomas; McHenry, Lee; Sherman, Stuart; Fogel, Evan L; Watkins, James L; Lehman, Glen A
2016-04-28
To evaluate pain control in chronic pancreatitis patients who underwent total pancreatectomy with islet cell transplantation or intrathecal narcotic pump infusion. We recognized 13 patients who underwent intrathecal narcotic pump (ITNP) infusion and 57 patients who underwent total pancreatectomy with autologous islet cell transplantation (TP + ICT) for chronic pancreatitis (CP) pain control between 1998 and 2008 at Indiana University Hospital. All patients had already failed multiple other modalities for pain control and the decision to proceed with either intervention was made at the discretion of the patients and their treating physicians. All patients were evaluated retrospectively using a questionnaire inquiring about their pain control (using a 0-10 pain scale), daily narcotic dose usage, and hospital admission days for pain control before each intervention and during their last follow-up. All 13 ITNP patients and 30 available TP + ICT patients were evaluated. The mean age was approximately 40 years in both groups. The median duration of pain before intervention was 6 years and 7 years in the ITNP and TP + ICT groups, respectively. The median pain score dropped from 8 to 2.5 (on a scale of 0-10) in both groups on their last follow up. The median daily dose of narcotics also decreased from 393 mg equivalent of morphine sulfate to 8 mg in the ITNP group and from 300 mg to 40 mg in the TP + ICT group. No patient had diabetes mellitus (DM) before either procedure whereas 85% of those who underwent pancreatectomy were insulin dependent on their last evaluation despite ICT. ITNP and TP + ICT are comparable for pain control in patients with CP however with high incidence of DM among those who underwent TP + ICT. Prospective comparative studies and longer follow up are needed to better define treatment outcomes.
Mokadem, Mohamad; Noureddine, Lama; Howard, Thomas; McHenry, Lee; Sherman, Stuart; Fogel, Evan L; Watkins, James L; Lehman, Glen A
2016-01-01
AIM: To evaluate pain control in chronic pancreatitis patients who underwent total pancreatectomy with islet cell transplantation or intrathecal narcotic pump infusion. METHODS: We recognized 13 patients who underwent intrathecal narcotic pump (ITNP) infusion and 57 patients who underwent total pancreatectomy with autologous islet cell transplantation (TP + ICT) for chronic pancreatitis (CP) pain control between 1998 and 2008 at Indiana University Hospital. All patients had already failed multiple other modalities for pain control and the decision to proceed with either intervention was made at the discretion of the patients and their treating physicians. All patients were evaluated retrospectively using a questionnaire inquiring about their pain control (using a 0-10 pain scale), daily narcotic dose usage, and hospital admission days for pain control before each intervention and during their last follow-up. RESULTS: All 13 ITNP patients and 30 available TP + ICT patients were evaluated. The mean age was approximately 40 years in both groups. The median duration of pain before intervention was 6 years and 7 years in the ITNP and TP + ICT groups, respectively. The median pain score dropped from 8 to 2.5 (on a scale of 0-10) in both groups on their last follow up. The median daily dose of narcotics also decreased from 393 mg equivalent of morphine sulfate to 8 mg in the ITNP group and from 300 mg to 40 mg in the TP + ICT group. No patient had diabetes mellitus (DM) before either procedure whereas 85% of those who underwent pancreatectomy were insulin dependent on their last evaluation despite ICT. CONCLUSION: ITNP and TP + ICT are comparable for pain control in patients with CP however with high incidence of DM among those who underwent TP + ICT. Prospective comparative studies and longer follow up are needed to better define treatment outcomes. PMID:27122666
Vousden, Dulcie A; Cox, Elizabeth; Allemang-Grand, Rylan; Laliberté, Christine; Qiu, Lily R; Lindenmaier, Zsuzsa; Nieman, Brian J; Lerch, Jason P
2018-06-01
Manganese-enhanced magnetic resonance imaging (MEMRI) is a widely used technique in rodent neuroimaging studies. Traditionally, Mn 2+ is delivered to animals via a systemic injection; however, this can lead to toxic effects at high doses. Recent studies have shown that subcutaneously implanted mini-osmotic pumps can be used to continuously deliver manganese chloride (MnCl 2 ), and that they produce satisfactory contrast while circumventing many of the toxic side effects. However, neither the time-course of signal enhancement nor the effect of continuous Mn 2+ delivery on behaviour, particularly learning and memory, have been well-characterized. Here, we investigated the effect of MnCl 2 dose and route of administration on a) spatial learning in the Morris Water Maze and b) tissue signal enhancement in the mouse brain. Even as early as 3 days after pump implantation, infusion of 25-50 mg/kg/day MnCl 2 via osmotic pump produced signal enhancement as good as or better than that achieved 24 h after a single 50 mg/kg intraperitoneal injection. Neither route of delivery nor MnCl 2 dose adversely affected spatial learning and memory on the water maze. However, especially at higher doses, mice receiving MnCl 2 via osmotic pumps developed skin ulceration which limited the imaging window. With these findings, we provide recommendations for route and dose of MnCl 2 to use for different study designs. Copyright © 2018 Elsevier Inc. All rights reserved.
Li, Yuqian; Li, Zhihong; Li, Min; Yang, Yanlong; Wang, Bao; Gao, Li; Zhang, Xingye; Cheng, Hongyu; Fang, Wei; Zhao, Bo; Wang, Boliang; Gao, Guodong; Li, Lihong
2015-06-17
Elevated intracranial pressure is one of the most common problems in patients with diverse intracranial disorders, leading to increased morbidity and mortality. Effective management for increased intracranial pressure is based mainly on surgical and medical techniques with hyperosmolar therapy as one of the core medical treatments. The study aimed to explore the effects of continuous micro-pump infusions of 3% hypertonic saline combined with furosemide on intracranial pressure control. We analyzed data on 56 eligible participants with intracranial pressure >20 mmHg from March 2013 to July 2014. The target was to increase and maintain plasma sodium to a level between 145 and 155 mmol/L and osmolarity to a level of 310 to 320 mOsmol/kg. Plasma sodium levels significantly increased from 138±5 mmol/L at admission to 151±3 mmol/L at 24 h (P<0.01). Osmolarity increased from 282±11 mOsmol/kg at baseline to 311±8 mOsmol/kg at 24 h (P<0.01). Intracranial pressure significantly decreased from 32±7 mmHg to 15±6 mmHg at 24 h (P<0.01). There was a significant improvement in CPP (P<0.01). Moreover, central venous pressure, mean arterial pressure, and Glasgow Coma Scale slightly increased. However, these changes were not statistically significant. Continuous infusion of 3% hypertonic saline + furosemide is effective and safe for intracranial pressure control.
Banting Memorial Lecture 2014* Technology and diabetes care: appropriate and personalized.
Pickup, J C
2015-01-01
Continuous subcutaneous insulin infusion was initially developed as a research procedure in the 1970s but quickly became a routine treatment for selected people with Type 1 diabetes. Continuous subcutaneous insulin infusion and other diabetes technologies, such as continuous glucose monitoring, are now an established and evidence-based part of diabetes care, but there has been some confusion about effectiveness and best use, particularly because of conflicting results from meta-analyses. This is because literature summary meta-analyses (including all trials) are inappropriate for therapeutic and economic decision-making; such meta-analyses should only include trials representative of groups likely to benefit. For example, for continuous subcutaneous insulin infusion, this would be those with continued disabling hypoglycaemia or elevated HbA1c levels. Alternatively, individual patient data meta-analysis allows modelling of covariates that determine effect size, e.g. in the case of continuous glucose monitoring, baseline HbA1c and frequency of sensor usage. Diabetes technology is therefore an example of personalized medicine, where evaluation and use should be both appropriate and targeted. This will also apply to future technologies such as new 'patch' pumps for Type 2 diabetes, closed-loop insulin delivery systems and nanomedicine applications in diabetes that we are currently researching. These include fluorescence lifetime-based non-invasive glucose monitoring and nanoencapsulation of islets for improved post-transplant survival. © 2014 The Author. Diabetic Medicine © 2014 Diabetes UK.
Shargil, A A
1987-03-01
Thirty husbands in childless couples, aged 24 to 35 years, were treated with luteinizing hormone-releasing hormone (LH-RH) for idiopathic hypogonadotropic hypogonadism (IHH) of peripubertal (incomplete) type. They were azoospermic or oligospermic, with less than 1.5 X 10(6)/ml nonmotile spermatozoa. The diagnosis of IHH was based on clinical and laboratory features and testicular biopsy specimen study and was further supported by results of stimulation tests and gonadotropin-releasing hormone (GnRH) test. Two treatment modalities were used: subcutaneous injections of 500 micrograms LH-RH twice daily; and perpetual subcutaneous injection, via portable infusion pump, of 25 ng/kg LH-RH, at 90-minute intervals. Two patients required a short second period of pulsatile treatment to cause a second pregnancy of their spouses. The pump proved to yield better results, compared with intermittent injections, in respect to endocrine responses, spermatogenesis, and fertility capacity. Normal levels of luteinizing hormone and follicle-stimulating hormone were reached in 2 to 3 weeks and normal testosterone levels in 8 to 10 weeks from the start of treatment. Sperm counts rose to greater than 60 X 10(6)/ml viable spermatozoa with less than 15% of abnormal forms in 3 to 5 months, and the wives conceived. Of a total of 18 deliveries of healthy infants, 12 offspring were identified genetically with their fathers. Four women were still pregnant at the conclusion of the study. The pump was well tolerated, without special operational problems to the patients. Pulsatile treatment is therefore recommended in the treatment of well-diagnosed and carefully selected cases of incomplete IHH.
Macaire, P; Nadhari, M; Greiss, H; Godwin, A; Elhanfi, O; Sainudeen, S; Abdul, M; Capdevila, X
2014-01-01
During continuous peripheral nerve blocks, infusion adjustments are essential for postoperative analgesia without side effects. Beside, physicians and nurse visits related to pump's settings and monitoring are time consuming and costly. We hypothesized that a remote control of pump's settings, by telemedicine transmission, adjusted to patients' feedbacks, is feasible and interesting in optimizing patient's postoperative pain management. Fifty-nine ASA physical status I and II patients were included. Ropivacaine 0.2% was infused during 72 h in CPNB catheters. After returning to the surgical ward, the patient was allowed to answer a 10 indicators questionnaire 3 times a day (8.00 AM, 2.00 PM, 8.00 PM), or unlimited on patient's demand. This information was transmitted from the pump to a server through the Internet. If one indicator was out of the predefined thresholds, the anesthesiologist in charge was immediately informed by texto on his cell phone. The anesthesiologist connected to the website, checked the data from the patient and modified the settings of the pump by remote control according to a written protocol. The changes need a secure access with a password and a confirmation. The number of settings changes, the time to realize the procedure and the adverse events related to the technique were noted. When the catheter was removed, the pump was unassigned to the patient and the data archived. Thirty sciatic, 24 femoral and 5 interscalene catheters were inserted in 59 patients. Five catheters were accidentally removed before the end of the 72-h period. The median VAS pain values at rest and during movement were respectively at 2 and 3. Sixteen patients complained about numbness promoting 2 (0-3) changes in pump settings; 9 about motor blockade with 1 (0-2) change; 5 about difficulties for physiotherapy with 1 (0-3) change. The mean time of pump settings modification after response to questionnaire or voluntarily patient's alert was 15 ± 2.2 minutes. Early physiotherapy in the surgical ward was totally uneventful in 54 patients. The mean value of satisfaction scale of the patients was 8.4 ± 1.6. No adverse event necessitated a postoperative analgesia technique change. Remote control pump's feedbacks and e-settings for postoperative analgesia using CPNB permitted a real adaptation to patients' needs, complaints and pain VAS values without nurse and physician physical intervention. Copyright © 2013. Published by Elsevier SAS.
Imantalab, Vali; Mirmansouri, Ali; Mohammadzadeh Jouryabi, Ali; Naderi Nabi, Bahram; Kanani, Gholamreza; Nassiri Sheikhani, Nassir; Atrkarroushan, Zahra; Ghazanfar Tehran, Samaneh; Samadpour, Nastaran
2017-10-01
Postoperative pain is a complex process commonly caused by surgical trauma. It is one of the major concerns of patients undergoing heart surgery. Despite new techniques and modern analgesic treatments, postoperative pain is still one of the most important controversial issues. 68 patients scheduled for elective CABG with CPB were included in a prospective, double-blind clinical trial. They were randomly divided into two groups. One group received PCA pump including morphine (group P) with underlying infusion of 0.02 mg/kg/Qh, bolus dose of 1 mg, lockout time of 15 minutes, and a maximum of 4 bolus of 0.02 mg/kg for one hour and the other group received morphine bolus (group B). Three patients were excluded from the study, and 33 and 32 patients participated in the groups P and B, respectively. Variables including age, gender, pump time, aortic clamp time, duration of surgery, complications (nausea and vomiting, GI Bleeding, and hypoxia), level of pain based on VAS, opioid consumption, hemodynamic, and sedation status were measured in both groups. There was no significant difference between the groups regarding age, gender, pump time, clamp time, duration of surgery, complication, sedation score, and hemodynamic status in most of the assessment periods. By assessing the pain severity in the groups at different periods, results showed a significant difference between the groups except at enrollment, and a lower severity of pain was noted in the group P compared to the group B. The consumed opioid was significantly higher in the group P than in the group B. However, higher doses of diclofenac and paracetamol were administered in the group B compared to the group P. Results showed that higher morphine would be used in patients with PCA pump after extubation following heart surgery, and this increased dose of opioid was associated with better pain control and lack of complication. Therefore, PCA pump with underlying infusion could be effectively used in patients undergoing CABG that are directly assessed in intensive care unite.
Imantalab, Vali; Mirmansouri, Ali; Mohammadzadeh Jouryabi, Ali; Naderi Nabi, Bahram; Kanani, Gholamreza; Nassiri Sheikhani, Nassir; Atrkarroushan, Zahra; Ghazanfar Tehran, Samaneh; Samadpour, Nastaran
2017-01-01
Background Postoperative pain is a complex process commonly caused by surgical trauma. It is one of the major concerns of patients undergoing heart surgery. Despite new techniques and modern analgesic treatments, postoperative pain is still one of the most important controversial issues. Methods 68 patients scheduled for elective CABG with CPB were included in a prospective, double-blind clinical trial. They were randomly divided into two groups. One group received PCA pump including morphine (group P) with underlying infusion of 0.02 mg/kg/Qh, bolus dose of 1 mg, lockout time of 15 minutes, and a maximum of 4 bolus of 0.02 mg/kg for one hour and the other group received morphine bolus (group B). Three patients were excluded from the study, and 33 and 32 patients participated in the groups P and B, respectively. Variables including age, gender, pump time, aortic clamp time, duration of surgery, complications (nausea and vomiting, GI Bleeding, and hypoxia), level of pain based on VAS, opioid consumption, hemodynamic, and sedation status were measured in both groups. Results There was no significant difference between the groups regarding age, gender, pump time, clamp time, duration of surgery, complication, sedation score, and hemodynamic status in most of the assessment periods. By assessing the pain severity in the groups at different periods, results showed a significant difference between the groups except at enrollment, and a lower severity of pain was noted in the group P compared to the group B. The consumed opioid was significantly higher in the group P than in the group B. However, higher doses of diclofenac and paracetamol were administered in the group B compared to the group P. Conclusions Results showed that higher morphine would be used in patients with PCA pump after extubation following heart surgery, and this increased dose of opioid was associated with better pain control and lack of complication. Therefore, PCA pump with underlying infusion could be effectively used in patients undergoing CABG that are directly assessed in intensive care unite. PMID:29696108
Integrating technology to improve medication administration.
Prusch, Amanda E; Suess, Tina M; Paoletti, Richard D; Olin, Stephen T; Watts, Starann D
2011-05-01
The development, implementation, and evaluation of an i.v. interoperability program to advance medication safety at the bedside are described. I.V. interoperability integrates intelligent infusion devices (IIDs), the bar-code-assisted medication administration system, and the electronic medication administration record system into a bar-code-driven workflow that populates provider-ordered, pharmacist-validated infusion parameters on IIDs. The purpose of this project was to improve medication safety through the integration of these technologies and decrease the potential for error during i.v. medication administration. Four key phases were essential to developing and implementing i.v. interoperability: (a) preparation, (b) i.v. interoperability pilot, (c) preliminary validation, and (d) expansion. The establishment of pharmacy involvement in i.v. interoperability resulted in two additional safety checks: pharmacist infusion rate oversight and nurse independent validation of the autoprogrammed rate. After instituting i.v. interoperability, monthly compliance to the telemetry drug library increased to a mean ± S.D. of 72.1% ± 2.1% from 56.5% ± 1.5%, and the medical-surgical nursing unit's drug library monthly compliance rate increased to 58.6% ± 2.9% from 34.1% ± 2.6% (p < 0.001 for both comparisons). The number of manual pump edits decreased with both telemetry and medical-surgical drug libraries, demonstrating a reduction from 56.9 ± 12.8 to 14.2 ± 3.9 and from 61.2 ± 15.4 to 14.7 ± 3.8, respectively (p < 0.001 for both comparisons). Through the integration and incorporation of pharmacist oversight for rate changes, the telemetry and medical-surgical patient care areas demonstrated a 32% reduction in reported monthly errors involving i.v. administration of heparin. By integrating two stand-alone technologies, i.v. interoperability was implemented to improve medication administration. Medication errors were reduced, nursing workflow was simplified, and pharmacists became involved in checking infusion rates of i.v. medications.
Formal verification of medical monitoring software using Z language: a representative sample.
Babamir, Seyed Morteza; Borhani, Mehdi
2012-08-01
Medical monitoring systems are useful aids assisting physicians in keeping patients under constant surveillance; however, taking sound decision by the systems is a physician concern. As a result, verification of the systems behavior in monitoring patients is a matter of significant. The patient monitoring is undertaken by software in modern medical systems; so, software verification of modern medial systems have been noticed. Such verification can be achieved by the Formal Languages having mathematical foundations. Among others, the Z language is a suitable formal language has been used to formal verification of systems. This study aims to present a constructive method to verify a representative sample of a medical system by which the system is visually specified and formally verified against patient constraints stated in Z Language. Exploiting our past experience in formal modeling Continuous Infusion Insulin Pump (CIIP), we think of the CIIP system as a representative sample of medical systems in proposing our present study. The system is responsible for monitoring diabetic's blood sugar.
AP@home: a novel European approach to bring the artificial pancreas home.
Heinemann, Lutz; Benesch, Carsten; DeVries, J Hans
2011-11-01
The development of an artificial pancreas (AP) made huge strides from 2006 to 2008 and a large number of activities are going on in this area of research. Until now, most AP systems under development were tested only under highly controlled conditions. The aim of our project, funded by the European Union, is to develop an AP system to such a level that it can be studied under daily life conditions at the home of patients with diabetes (hence AP@home). Based on a subcutaneous-subcutaneous closed-loop strategy (i.e., glucose sensing and insulin infusion in the subcutaneous tissue), two different approaches will be taken to achieve this aim: a two-port AP system and a single-port AP system. The two-port AP system will use off-the-shelf-components for the glucose sensor and insulin pump in combination with closed-loop algorithms generated in Europe. As to the single-port AP system, two different innovative single-port systems will be developed; in this case, continuous glucose monitoring and insulin infusion will take place via a single catheter. The first clinical trials with the two-port AP system under controlled clinical conditions have started and good progress has been made in the development of the single-port AP systems. We believe that our consortium of 12 European partners, which builds on existing achievements and close cooperation between academic centers and industry, can contribute substantially to the development of an AP system that can be used by patients in daily life. © 2011 Diabetes Technology Society.
Test and Evaluation Report of the IMED Volumetric Infusion Pump Model 960A
1992-02-01
tested Ambient tempera- ture was out of test lim- its. Windshield anti-ice X Pitot heat X Vent blower X Windshield wiper X Heater X APU X Generator #1 X...Patterson John A. Dellinger, Air Force Base, OH 45433 Southwest Research Institute P. 0. Box 28510 Henry L. Taylor San Antonio, TX 78284 Director
Abraham, Mary B; de Bock, Martin; Paramalingam, Nirubasini; O'Grady, Michael J; Ly, Trang T; George, Carly; Roy, Anirban; Spital, Glenn; Karula, Sophy; Heels, Kristine; Gebert, Rebecca; Fairchild, Jan M; King, Bruce R; Ambler, Geoffrey R; Cameron, Fergus; Davis, Elizabeth A; Jones, Timothy W
2016-07-01
Sensor-augmented pump therapy (SAPT) with algorithms to predict impending low blood glucose and suspend insulin delivery has the potential to reduce hypoglycemia exposure. The aim of this study was to determine whether predictive low glucose management (PLGM) system is effective in preventing insulin-induced hypoglycemia in controlled experiments. Two protocols were used to induce hypoglycemia in an in-clinic environment. (A) Insulin bolus: Insulin was administered as a manual bolus through the pump. (B) Increased basal insulin: Hypoglycemia was induced by increasing basal rates overnight to 180%. For both protocols, participants were randomized and studied on 2 separate days; a control day with SAPT alone and an intervention day with SAPT and PLGM activated. The predictive algorithm was programmed to suspend basal insulin infusion when sensor glucose was predicted to be <80 mg/dL in 30 min. The primary outcome was the requirement for hypoglycemia treatment (symptomatic hypoglycemia or plasma glucose <50 mg/dL) and was compared in both control and intervention arms. With insulin bolus, 24/28 participants required hypoglycemia treatment with SAPT alone compared to 5/28 participants when PLGM was activated (P ≤ 0.001). With increased basal rates, all the eight SAPT-alone participants required treatment for hypoglycemia compared to only one with SAPT and PLGM. There was no post pump-suspend hyperglycemia with insulin bolus (P = 0.4) or increased basal rates (P = 0.69) in participants with 2-h pump suspension on intervention days. SAPT with PLGM reduced the requirement for hypoglycemia treatment following insulin-induced hypoglycemia in an in-clinic setting.
1998-01-01
Bioreactor Demonstration System (BDS) comprises an electronics module, a gas supply module, and the incubator module housing the rotating wall vessel and its support systems. Nutrient media are pumped through an oxygenator and the culture vessel. The shell rotates at 0.5 rpm while the irner filter typically rotates at 11.5 rpm to produce a gentle flow that ensures removal of waste products as fresh media are infused. Periodically, some spent media are pumped into a waste bag and replaced by fresh media. When the waste bag is filled, an astronaut drains the waste bag and refills the supply bag through ports on the face of the incubator. Pinch valves and a perfusion pump ensure that no media are exposed to moving parts. An Experiment Control Computer controls the Bioreactor, records conditions, and alerts the crew when problems occur. The crew operates the system through a laptop computer displaying graphics designed for easy crew training and operation. The work is sponsored by NASA's Office of Biological and Physical Research. The bioreactor is managed by the Biotechnology Cell Science Program at NASA's Johnson Space Center (JSC). NASA-sponsored bioreactor research has been instrumental in helping scientists to better understand normal and cancerous tissue development. In cooperation with the medical community, the bioreactor design is being used to prepare better models of human colon, prostate, breast and ovarian tumors. Cartilage, bone marrow, heart muscle, skeletal muscle, pancreatic islet cells, liver and kidney are just a few of the normal tissues being cultured in rotating bioreactors by investigators. See No. 0101823 for a version without labels, and No. 0103180 for an operational schematic.
1998-01-01
Bioreactor Demonstration System (BDS) comprises an electronics module, a gas supply module, and the incubator module housing the rotating wall vessel and its support systems. Nutrient media are pumped through an oxygenator and the culture vessel. The shell rotates at 0.5 rpm while the irner filter typically rotates at 11.5 rpm to produce a gentle flow that ensures removal of waste products as fresh media are infused. Periodically, some spent media are pumped into a waste bag and replaced by fresh media. When the waste bag is filled, an astronaut drains the waste bag and refills the supply bag through ports on the face of the incubator. Pinch valves and a perfusion pump ensure that no media are exposed to moving parts. An Experiment Control Computer controls the Bioreactor, records conditions, and alerts the crew when problems occur. The crew operates the system through a laptop computer displaying graphics designed for easy crew training and operation. The work is sponsored by NASA's Office of Biological and Physical Research. The bioreactor is managed by the Biotechnology Cell Science Program at NASA's Johnson Space Center (JSC). NASA-sponsored bioreactor research has been instrumental in helping scientists to better understand normal and cancerous tissue development. In cooperation with the medical community, the bioreactor design is being used to prepare better models of human colon, prostate, breast and ovarian tumors. Cartilage, bone marrow, heart muscle, skeletal muscle, pancreatic islet cells, liver and kidney are just a few of the normal tissues being cultured in rotating bioreactors by investigators. See No. 0101816 for a version without labels, and No. 0103180 for an operational schematic.
1998-01-01
Bioreactor Demonstration System (BDS) comprises an electronics module, a gas supply module, and the incubator module housing the rotating wall vessel and its support systems. Nutrient media are pumped through an oxygenator and the culture vessel. The shell rotates at 0.5 rpm while the irner filter typically rotates at 11.5 rpm to produce a gentle flow that ensures removal of waste products as fresh media are infused. Periodically, some spent media are pumped into a waste bag and replaced by fresh media. When the waste bag is filled, an astronaut drains the waste bag and refills the supply bag through ports on the face of the incubator. Pinch valves and a perfusion pump ensure that no media are exposed to moving parts. An Experiment Control Computer controls the Bioreactor, records conditions, and alerts the crew when problems occur. The crew operates the system through a laptop computer displaying graphics designed for easy crew training and operation. The work is sponsored by NASA's Office of Biological and Physical Research. The bioreactor is managed by the Biotechnology Cell Science Program at NASA's Johnson Space Center (JSC). NASA-sponsored bioreactor research has been instrumental in helping scientists to better understand normal and cancerous tissue development. In cooperation with the medical community, the bioreactor design is being used to prepare better models of human colon, prostate, breast and ovarian tumors. Cartilage, bone marrow, heart muscle, skeletal muscle, pancreatic islet cells, liver and kidney are just a few of the normal tissues being cultured in rotating bioreactors by investigators. See No. 0101825 for a version with major elements labeled, and No. 0103180 for an operational schematic. 0101816
1998-01-01
Bioreactor Demonstration System (BDS) comprises an electronics module, a gas supply module, and the incubator module housing the rotating wall vessel and its support systems. Nutrient media are pumped through an oxygenator and the culture vessel. The shell rotates at 0.5 rpm while the irner filter typically rotates at 11.5 rpm to produce a gentle flow that ensures removal of waste products as fresh media are infused. Periodically, some spent media are pumped into a waste bag and replaced by fresh media. When the waste bag is filled, an astronaut drains the waste bag and refills the supply bag through ports on the face of the incubator. Pinch valves and a perfusion pump ensure that no media are exposed to moving parts. An Experiment Control Computer controls the Bioreactor, records conditions, and alerts the crew when problems occur. The crew operates the system through a laptop computer displaying graphics designed for easy crew training and operation. The work is sponsored by NASA's Office of Biological and Physical Research. The bioreactor is managed by the Biotechnology Cell Science Program at NASA's Johnson Space Center (JSC). NASA-sponsored bioreactor research has been instrumental in helping scientists to better understand normal and cancerous tissue development. In cooperation with the medical community, the bioreactor design is being used to prepare better models of human colon, prostate, breast and ovarian tumors. Cartilage, bone marrow, heart muscle, skeletal muscle, pancreatic islet cells, liver and kidney are just a few of the normal tissues being cultured in rotating bioreactors by investigators. See No. 0101824 for a version with labels, and No. 0103180 for an operational schematic.
NASA Technical Reports Server (NTRS)
1998-01-01
Bioreactor Demonstration System (BDS) comprises an electronics module, a gas supply module, and the incubator module housing the rotating wall vessel and its support systems. Nutrient media are pumped through an oxygenator and the culture vessel. The shell rotates at 0.5 rpm while the irner filter typically rotates at 11.5 rpm to produce a gentle flow that ensures removal of waste products as fresh media are infused. Periodically, some spent media are pumped into a waste bag and replaced by fresh media. When the waste bag is filled, an astronaut drains the waste bag and refills the supply bag through ports on the face of the incubator. Pinch valves and a perfusion pump ensure that no media are exposed to moving parts. An Experiment Control Computer controls the Bioreactor, records conditions, and alerts the crew when problems occur. The crew operates the system through a laptop computer displaying graphics designed for easy crew training and operation. The work is sponsored by NASA's Office of Biological and Physical Research. The bioreactor is managed by the Biotechnology Cell Science Program at NASA's Johnson Space Center (JSC). NASA-sponsored bioreactor research has been instrumental in helping scientists to better understand normal and cancerous tissue development. In cooperation with the medical community, the bioreactor design is being used to prepare better models of human colon, prostate, breast and ovarian tumors. Cartilage, bone marrow, heart muscle, skeletal muscle, pancreatic islet cells, liver and kidney are just a few of the normal tissues being cultured in rotating bioreactors by investigators. See No. 0101825 for a version with major elements labeled, and No. 0103180 for an operational schematic. 0101816
NASA Technical Reports Server (NTRS)
1998-01-01
Bioreactor Demonstration System (BDS) comprises an electronics module, a gas supply module, and the incubator module housing the rotating wall vessel and its support systems. Nutrient media are pumped through an oxygenator and the culture vessel. The shell rotates at 0.5 rpm while the irner filter typically rotates at 11.5 rpm to produce a gentle flow that ensures removal of waste products as fresh media are infused. Periodically, some spent media are pumped into a waste bag and replaced by fresh media. When the waste bag is filled, an astronaut drains the waste bag and refills the supply bag through ports on the face of the incubator. Pinch valves and a perfusion pump ensure that no media are exposed to moving parts. An Experiment Control Computer controls the Bioreactor, records conditions, and alerts the crew when problems occur. The crew operates the system through a laptop computer displaying graphics designed for easy crew training and operation. The work is sponsored by NASA's Office of Biological and Physical Research. The bioreactor is managed by the Biotechnology Cell Science Program at NASA's Johnson Space Center (JSC). NASA-sponsored bioreactor research has been instrumental in helping scientists to better understand normal and cancerous tissue development. In cooperation with the medical community, the bioreactor design is being used to prepare better models of human colon, prostate, breast and ovarian tumors. Cartilage, bone marrow, heart muscle, skeletal muscle, pancreatic islet cells, liver and kidney are just a few of the normal tissues being cultured in rotating bioreactors by investigators. See No. 0101816 for a version without labels, and No. 0103180 for an operational schematic.
NASA Technical Reports Server (NTRS)
1998-01-01
Bioreactor Demonstration System (BDS) comprises an electronics module, a gas supply module, and the incubator module housing the rotating wall vessel and its support systems. Nutrient media are pumped through an oxygenator and the culture vessel. The shell rotates at 0.5 rpm while the irner filter typically rotates at 11.5 rpm to produce a gentle flow that ensures removal of waste products as fresh media are infused. Periodically, some spent media are pumped into a waste bag and replaced by fresh media. When the waste bag is filled, an astronaut drains the waste bag and refills the supply bag through ports on the face of the incubator. Pinch valves and a perfusion pump ensure that no media are exposed to moving parts. An Experiment Control Computer controls the Bioreactor, records conditions, and alerts the crew when problems occur. The crew operates the system through a laptop computer displaying graphics designed for easy crew training and operation. The work is sponsored by NASA's Office of Biological and Physical Research. The bioreactor is managed by the Biotechnology Cell Science Program at NASA's Johnson Space Center (JSC). NASA-sponsored bioreactor research has been instrumental in helping scientists to better understand normal and cancerous tissue development. In cooperation with the medical community, the bioreactor design is being used to prepare better models of human colon, prostate, breast and ovarian tumors. Cartilage, bone marrow, heart muscle, skeletal muscle, pancreatic islet cells, liver and kidney are just a few of the normal tissues being cultured in rotating bioreactors by investigators. See No. 0101823 for a version without labels, and No. 0103180 for an operational schematic.
NASA Technical Reports Server (NTRS)
1998-01-01
Bioreactor Demonstration System (BDS) comprises an electronics module, a gas supply module, and the incubator module housing the rotating wall vessel and its support systems. Nutrient media are pumped through an oxygenator and the culture vessel. The shell rotates at 0.5 rpm while the irner filter typically rotates at 11.5 rpm to produce a gentle flow that ensures removal of waste products as fresh media are infused. Periodically, some spent media are pumped into a waste bag and replaced by fresh media. When the waste bag is filled, an astronaut drains the waste bag and refills the supply bag through ports on the face of the incubator. Pinch valves and a perfusion pump ensure that no media are exposed to moving parts. An Experiment Control Computer controls the Bioreactor, records conditions, and alerts the crew when problems occur. The crew operates the system through a laptop computer displaying graphics designed for easy crew training and operation. The work is sponsored by NASA's Office of Biological and Physical Research. The bioreactor is managed by the Biotechnology Cell Science Program at NASA's Johnson Space Center (JSC). NASA-sponsored bioreactor research has been instrumental in helping scientists to better understand normal and cancerous tissue development. In cooperation with the medical community, the bioreactor design is being used to prepare better models of human colon, prostate, breast and ovarian tumors. Cartilage, bone marrow, heart muscle, skeletal muscle, pancreatic islet cells, liver and kidney are just a few of the normal tissues being cultured in rotating bioreactors by investigators. See No. 0101824 for a version with labels, and No. 0103180 for an operational schematic.
Fisher, R. B.; Gardner, M. L. G.
1974-01-01
1. A new preparation of isolated rat jejunum plus ileum (ca. 100 cm) is described in which a saline infusate is pumped into the superior mesenteric artery, the superior mesenteric vein having been ligated. 2. The arterial infusate washes out the tissue spaces: the lumen is perfused in a single pass with a segmented flow as by Fisher & Gardner (1974). 3. At an arterial infusion rate of 3 ml./min, steady states are set up in the tissue fluid within 10-15 min: the compositions of the fluids bathing both sides of the mucosa can therefore be controlled. 4. The rate of glucose absorption from the lumen falls only gradually when the luminal sodium is replaced by choline abruptly while the tissue fluid sodium is maintained at 144 m-equiv/l. by arterial infusion. 5. The rate of glucose absorption from the lumen is unaffected by replacement of sodium in the arterial infusate by choline. 6. Ouabain (10-4 M) in an arterial infusate containing sodium 144 m-equiv/l. causes inhibition of glucose and water absorption from the lumen. There is no effect of ouabain when the arterial infusate contains sodium, 0 or 72 m-equiv/l. 7. Arterial ouabain does not reverse the effects of depletion of luminal sodium. Simultaneous removal of luminal sodium and application of arterial ouabain causes faster inhibition of glucose absorption than does either treatment alone. 8. Glucose absorption is more likely to depend on rate of efflux of sodium from mucosal cell to tissue fluid than on a sodium gradient at the brush border or on intracellular sodium concentration. PMID:4422318
Soltani, Ghasem; Jahanbakhsh, Saeed; Tashnizi, Mohammad Abbasi; Fathi, Mehdi; Amini, Shahram; Zirak, Nahid; Sheybani, Shima
2017-10-01
Arrhythmia occurring during and after surgery is one of the major complications in open-heart surgery. Dexmedetomidine is an intravenous alpha-2 agonist and very specific short-acting drug to protect the various organs against ischemic injuries and blood reflow. However, the effect of dexmedetomidine for preventing intraoperative heart arrhythmias has not been recognized. This study aimed to determine the effect of dexmedetomidine on the incidence rate of heart arrhythmias and anesthetic required in off-pump coronary artery bypass surgery. This randomized clinical trial was conducted on patients who were candidates for off-pump coronary artery bypass referring to Imam Reza Hospital of Mashhad, Iran, from July 2016 through January 2017. The patients were randomly assigned to two groups of intervention (infusion of 0.5 mcg/kg/h dexmedetomidine together with induction followed by infusion of 0.5 mcg/kg/h by the end of the surgery) or control (saline infusion). Mean arterial pressure (MAP) and heart rate (HR) were measured before induction, during surgery operation and ICU admission. Data were analyzed by SPSS version 18 using Chi Square and independent-samples t-test. A total of 76 patients with a mean age of 59.8 ± 8.2 years (in two groups of 38) were studied. The two groups had no statistically significant difference in terms of background variables. The MAP and HR values before induction, during surgery and ICU admission were significantly higher in the control group than in the intervention group (p=0.001). Out of the studied arrhythmias, the values of PAC (55.2% vs. 15.7%), PVC (81.5% vs. 21.0%), AF (26.3% vs. 7.8%), VTAC (21.0% vs. 2.6%) were significantly lower in dexmedetomidine group (p=0.001). It seems that dexmedetomidine administration during induction and surgery can cause significant reduction in most of the common arrhythmias in off-pump coronary bypass surgery. The use of dexmedetomidine maintains MAP and HR at significantly lower values, and changes compared to the control group as well as reduces the need for anesthetic compounds. The present study has been registered at the Iranian Registry of Clinical Trials (www.IRCT.IR) with a code of IRCT2016072413159N9 before starting the study. This study was fully sponsored by the Research Deputy at Mashhad University of Medical Sciences, Iran (grant number 941413).
A remote drip infusion monitoring system employing Bluetooth.
Amano, Hikaru; Ogawa, Hidekuni; Maki, Hiromichi; Tsukamoto, Sosuke; Yonezawa, Yoshiharu; Caldwell, W Morton
2012-01-01
We have developed a remote drip infusion monitoring system for use in hospitals. The system consists of several infusion monitoring devices and a central monitor. The infusion monitoring device employing a Bluetooth module can detect the drip infusion rate and an empty infusion solution bag, and then these data are sent to the central monitor placed at the nurses' station via the Bluetooth. The central monitor receives the data from several infusion monitoring devices and then displays graphically them. Therefore, the developed system can monitor intensively the drip infusion situation of the several patients at the nurses' station.
Fusco, Pierfrancesco; Cofini, Vincenza; Petrucci, Emiliano; Scimia, Paolo; Fiorenzi, Maurizio; Paladini, Giuseppe; Behr, Astrid U; Borghi, Battista; Flamini, Stefano; Pizzoferrato, Renzo; Colafarina, Olivo; Di Francesco, Alexander; Tabacco, Tito; Necozione, Stefano; Marinangeli, Franco
2018-05-01
Total hip arthroplasty is one of the most common procedures in orthopedic surgery. We hypothesized that local infiltration of analgesia and continuous wound infusion of anesthetics in the first 72 hours after surgery could provide more effective postoperative analgesia with better rehabilitation. A double-blind, randomized, controlled study was conducted with 96 patients who underwent total hip arthroplasty. The patients were randomized to receive either a local infiltration analgesia and continuous wound infusion of anesthetics or a local infiltration analgesia and continuous wound infusion of saline solution. The patients in both groups received subarachnoid anesthesia and a local infiltration analgesia. A multihole catheter was placed next to the implant and connected to an electronic pump containing a 300-mL solution of 0.2% levobupivacaine (experimental group) or saline (control group). A total of 96 consecutive patients were enrolled and randomized. Of these, 48 patients received local infiltration analgesia and continuous wound infusion of local anesthetics, and the remainder received local infiltration analgesia and continuous wound infusion of saline solution. The analysis showed a significant main effect of treatment on the postoperative incident of pain (Ftreat(1,93)=22.62, P=0.000) and on resting pain during the post-surgery follow-up (Ftreat(1,93)=15.62, P=0.0002). The pain scores during the rehabilitation period were significantly less in the experimental group. Analgesic consumption was less in the experimental group. The addition of continuous wound infusion of anesthetics to local infiltration analgesia provided an extended analgesic effect associated with good rehabilitation performance.
Hashimoto, Michio; Tozawa, Ryuichi; Katakura, Masanori; Shahdat, Hossain; Haque, Abdul Md; Tanabe, Yoko; Gamoh, Shuji; Shido, Osamu
2011-07-01
Deposition of amyloid β peptide (Aβ) into the brain causes cognitive impairment. We investigated whether prescription pre-administration of n-3 fatty acids improves cognitive learning ability in young rats and whether it protects against learning ability impairments in an animal model of Alzheimer's disease that was prepared by infusion of Aβ(1-40) into the cerebral ventricles of rats. Pre-administration of TAK-085 (highly purified and concentrated n-3 fatty acids containing eicosapentaenoic acid ethyl ester and docosahexaenoic acid ethyl ester) at 300 mg kg(-1) day(-1) for 12 weeks significantly reduced the number of reference memory errors in an 8-arm radial maze, suggesting that long-term administration of TAK-085 improves cognitive leaning ability in rats. After pre-administration, the control group was divided into the vehicle and Aβ-infused groups, whereas the TAK-085 pre-administration group was divided into the TAK-085 and TAK-085 + Aβ groups (TAK-085-pre-administered Aβ-infused rats). Aβ(1-40) or vehicle was infused into the cerebral ventricle using a mini osmotic pump. Pre-administration of TAK-085 to the Aβ-infused rats significantly suppressed the number of reference and working memory errors and decreased the levels of lipid peroxide and reactive oxygen species in the cerebral cortex and hippocampus of Aβ-infused rats, suggesting that TAK-085 increases antioxidative defenses. The present study suggests that long-term administration of TAK-085 is a possible therapeutic agent for protecting against Alzheimer's disease-induced learning deficiencies. This journal is © The Royal Society of Chemistry 2011
White, David; Waugh, Norman; Elliott, Jackie; Lawton, Julia; Barnard, Katharine; Campbell, Michael J; Dixon, Simon; Heller, Simon
2014-09-03
People with type 1 diabetes (T1DM) require insulin therapy to sustain life, and need optimal glycaemic control to prevent diabetic ketoacidosis and serious long-term complications. Insulin is generally administered using multiple daily injections but can also be delivered using an infusion pump (continuous subcutaneous insulin infusion), a more costly option with benefits for some patients. The UK National Institute for Health and Care Excellence (NICE) recommend the use of pumps for patients with the greatest need, citing insufficient evidence to approve extension to a wider population. Far fewer UK adults use pumps than in comparable countries. Previous trials of pump therapy have been small and of short duration and failed to control for training in insulin adjustment. This paper describes the protocol for a large randomised controlled trial comparing pump therapy with multiple daily injections, where both groups are provided with high-quality structured education. A multicentre, parallel group, cluster randomised controlled trial among 280 adults with T1DM. All participants attended the week-long dose adjustment for normal eating (DAFNE) structured education course, and receive either multiple daily injections or pump therapy for 2 years. The trial incorporates a detailed mixed-methods psychosocial evaluation and cost-effectiveness analysis. The primary outcome will be the change in glycosylated haemoglobin (HbA1c) at 24 months in those participants whose baseline HbA1c is at or above 7.5% (58 mmol/mol). The key secondary outcome will be the proportion of participants reaching the NICE target of an HbA1c of 7.5% (58 mmol/mol) or less at 24 months. The protocol was approved by the Research Ethics Committee North West, Liverpool East and received Medicines and Healthcare products Regulatory Agency (MHRA) clinical trials authorisation. Each participating centre gave National Health Service R&D approval. We shall disseminate study findings to study participants and through peer reviewed publications and conference presentations, including lay user groups. ISRCTN 61215213. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Complications of intrathecal opioids and bupivacaine in the treatment of "refractory" cancer pain.
Nitescu, P; Sjöberg, M; Appelgren, L; Curelaru, I
1995-03-01
To test the concept that externalized tunneled intrathecal catheters lead to a high risk of complications, such as meningitis and epidural abscess, and therefore should not be used for durations of intrathecal pain treatment of > 1 week. Prospective, cohort, nonrandomized, consecutive, historical control trial. Tertiary care center, institutional practice, hospitalized and ambulatory care. Two hundred adults (107 women, 93 men) with refractory cancer pain treated for 1-575 (median, 33; total, 14,485) days; 79 patients were treated at home for 2-226 (median, 36; total, 4,711) days. All patients had died by the close of the study. Insertion of intrathecal tunneled nylon (Portex) catheters (223 in 200 patients) with Millipore filters. The catheter hubs were securely fixed to the skin with steel sutures. Standardized care after insertion: (a) daily phone contact with the patients, their families, or the nurses in charge; (b) weekly dressing change at the tunnel outlet by the nurses; (c) refilling of the infusion containers by the nurses; (d) exchange of the infusion systems when empty (within 1 month) and of the antibacterial filter once a month by specially instructed Pain Department nurses. All contact between the connections of the syringes, cassettes, and needles with the operator's hands was carefully avoided during filling and refilling of the infusion containers and exchange of the antibacterial filters; no other aseptic precautions were taken. We recorded the rates of perfect function and complications of the systems. The rates of complications recorded in this study with externalized tunneled intrathecal catheters are discussed and compared with the rates reported in the literature with externalized (tunneled and non-tunneled) epidural and intrathecal catheters, as well as with internalized (both epidural and intrathecal) catheters connected to subcutaneous ports, reservoirs, and pumps. The following rates (as a percentage of number of patients) of perfect function and complications of the systems were recorded (the ranges of rates reported in the literature are given in parentheses): perfect function of the system, 93% (31-90%); accidental injury of an unknown epidural tumor followed by an epidural hematoma, 0.5% (0-6%); skin breakdown at the insertion site, 2% (2-50%); postdural puncture headache, 15.5% (10%); external leakage of CSF, 3.5% (4-27%); CSF hygroma ("pseudomeningocele"), 1.5% (4-6.25%); hearing loss and Ménière-like syndrome, 0% (12%); pain on injection, 0% with continuous infusion and 4.5% with intermittent injections (3-36% with intermittent injections); catheter tip dislodgement, 1.5% (6-33%); catheter (system) occlusion, 1% (3-12%); accidental catheter withdrawal, 4% (3-22%); catheter (system) leakage, 1.5% (2.1-26.6%); all mechanical complications, 8.5% (10-44%); local (catheter entry site) infection, 0.5% (2-33%); catheter track infection, 0% (6-25%); epidural abscess, 0% (0.6-25%); meningitis, 0.5% (1-25%); systemic infection, 0% (3%); incidence of all infections (n/treatment days), 1/7,242 (1/168-1/2,446). In our population and with the technique of insertion and care reported here, the use of externalized tunneled intrathecal catheters has not been associated with higher rates of complications when compared with earlier reported rates of externalized epidural catheters and internalized (both epidural and intrathecal) catheters connected to subcutaneously implanted ports, reservoirs, and pumps. The opinion that the use of externalized tunneled intrathecal catheters should be restricted only to patients who need pain treatment for < 1 week (because of the potential risk of infection, particularly meningitis and epidural abscess) is unfounded.
Yaksh, Tony L.; de Kater, Annelies; Dean, Robin; Best, Brookie M.; Miljanich, George P.
2012-01-01
SUMMARY Background and purpose Ziconotide is a peptide that blocks N-type calcium channels and is anti-hyperalgesic after intrathecal delivery. We here characterize the spinal kinetics of intrathecal bolus and infused ziconotide in dog. Experimental approach Male beagle dogs (N = 5) were prepared with chronic intrathecal (IT) lumbar injection and cerebrospinal fluid (LCSF) sampling catheters connected to vest-mounted pumps. Each dog received: i) IT bolus ziconotide (10 µg + 1 µCi 3H-inulin), ii) IT infusion for 48 hr of ziconotide (1 µg/100 µL/hr), iii) IT infusion for 48 hr of ziconotide (5 µg/100 µL/hr), and iv) intravenous injection of ziconotide (0.1 mg/kg). After IT bolus, LCSF ziconotide and inulin showed an initial peak and biphasic (distribtution/elimination) clearance (ziconotide T1/2 α / ß = 0.14 and 1.77 hr, and inulin T1/2 α / ß = 0.16 and 3.88 hr, respectively). The LCSF: plasma ziconotide concentration ratio was 20,000: 1 at 30 min, and 30: 1 at 8 hr. IT infusion of 1 and then 5 µg/hr resulted in LCSF concentrations that peaked by 8 hr and remained stable at 343 and 1380 ng/mL, respectively, to the end of the 48-hr infusions. Terminal elimination T1/2 after termination of continuous infusion was 2.47 hr. Ziconotide LCSF: cisternal CSF: plasma concentration ratios after infusion of 1 µg/hr and 5 µg/hr were 1: 0.017: 0.001 and 1: 0.015: 0.003, respectively. IT infusion of ziconotide at 1 µg/hr inhibited thermal skin twitch by 24 hr, and produced modest trembling, ataxia, and decreased arousal. Effects continued through the 48-hr infusion period, increased in magnitude during the subsequent 5 µg/hr infusion periods, and disappeared after drug clearance. Conclusions and Implications After intrathecal bolus or infusion, ziconotide displays linear kinetics that are consistent with a hydrophilic molecule of approximately 2500 Da that is cleared slightly more rapidly than inulin from the LCSF. Behavioral effects were dose dependent and reversible. PMID:22748108
Electromagnetic immunity of infusion pumps to GSM mobile phones: a systematic review.
Calcagnini, Giovanni; Censi, Federica; Triventi, Michele; Mattei, Eugenio; Bartolini, Pietro
2007-01-01
Electromagnetic interference with life-sustaining medical care devices has been reported by various groups. Previous studies have demonstrated that volumetric and syringe pumps are susceptible to false alarm buzzing and blocking, when exposed to various electromagnetic sources. The risk of electromagnetic interference depends on several factors such as the phone-emitted power, distance and carrier frequency, phone model and antenna type. The main recommendations and the relevant harmonized standard are also reported and discussed. >From the data available in literature emerges that, for distances lower than 1 m there is a non negligible risk of electromagnetic interferences, although significant differences exists in the reported minimum distances. Interference effects clinically relevant for the patients are rare. No permanent damage to the pumps has been ever reported, although in several cases intervention of personnel is required to resume normal operation.
Cozon, Grégoire Jacques Noël; Clerson, Pierre; Dokhan, Annaïk; Fardini, Yann; Sala, Taylor Pindi; Crave, Jean-Charles
2018-01-01
Patients with primary immunodeficiency (PID) often receive immunoglobulin replacement therapy (IgRT). Physicians and patients have the choice between various methods of administration. For subcutaneous immunoglobulin infusions, patients may use an automated pump (P) or push the plunger of a syringe (rapid push [RP]). P infusions are performed once a week and last around 1 hour. RP decreases the duration of administration, but requires more frequent infusions. Eight out of 30 patients (coming from a single center) who had participated in the cross-over, randomized, open-label trial comparing P and RP participated in a focus group or underwent in-depth interviews. Patients had a long history of home-based subcutaneous immunoglobulin using P. The trial suggested that RP had slightly greater interference on daily life than P, but similar efficacy and better cost-effectiveness. When asked about the delivery method they had preferred, around one-third of patients pointed out RP rather than P. In-depth interviews may reveal unforeseen reasons for patients' preferences. Interviews underlined the complexity of the relationship that the patients maintain with their disease and IgRT. Even if they recognized the genetic nature of the disease and claimed PID was a part of them, patients tried not to be overwhelmed by the disease. IgRT by P was well integrated in patients' routine. By contrast, RP too frequently reminded the patients of their disease. In addition, some patients pointed out the difficulty of pushing the plunger due to the viscosity of the product. Coming back too frequently, RP was not perceived as time saving over a week. Long-lasting use of P could partly explain patients' reasonable reluctance to change to RP. In-depth interviews of PID patients highlighted unforeseen reasons for patients' preference that the physician needs to explore during the shared medical decision-making process.
Region-specific DNA synthesis in brains of F344 rats following a six-day bromodeoxyuridine infusion.
Bolon, B; Dunn, C; Goldsworthy, T L
1996-09-01
Prolonged exposure to certain alkylating chemicals induces glial and meningeal tumours in rats, probably resulting from DNA damage to dividing neural cells. The present work evaluated DNA synthesis in the brains of untreated, young adult male F344 rats in order to define a BrdUrd infusion protocol to more adequately assess proliferation in slowly dividing neural cell populations. BrdUrd (2.5 to 160 mg/ml) was administered for 6 days via subcutaneous osmotic pumps. Clinical toxicity was not observed at any dose. The labelling index (LI; % of cells per brain area that incorporated BrdUrd) and unit length labelling index (ULLI; % of cells per meningeal length that incorporated BrdUrd) were calculated for selected regions by counting labelled neural cells in defined areas of the right hemisphere in coronal brain sections. Intensely stained cells were numerous in the cerebral subependymal layer (LI = 35.8%); scattered in cerebral white matter tracts (e.g. corpus callosum and internal capsule; LI = 6.2%) as well as cerebral (ULLI = 4.2%) and cerebellar (ULLI = 3.6%) meninges; and rare in the hippocampus (LI > 0.1%). Mildy stained cells were dispersed in the pons (LI = 2.1%), deep cerebral (LI = 1.8%) and cerebellar (LI = 1.0%) grey matter, and thalamus (LI = 0.3%). Phenotypically, BrdUrd-positive cells in neuropil were glial cell precursors and their progeny, while those associated with meninges were usually located in the superficial subarachnoid space and appeared to be fibrocytes. Using BrdUrd infusion, LI for glial precursors at these sites ranged from two- to 10-fold higher than those reported previously after a brief parenteral pulse dose. These data indicate that continuous BrdUrd infusion for 6 days by subcutaneous osmotic pump is an efficient means of labelling neural cells throughout the brain.
Ilfeld, Brian M.; Mariano, Edward R.; Girard, Paul J.; Loland, Vanessa J.; Meyer, R. Scott; Donovan, John F.; Pugh, George A.; Le, Linda T.; Sessler, Daniel I.; Shuster, Jonathan J.; Theriaque, Douglas W.; Ball, Scott T.
2010-01-01
A continuous femoral nerve block (cFNB) involves the percutaneous insertion of a catheter adjacent to the femoral nerve, followed by a local anesthetic infusion, improving analgesia following total knee arthroplasty (TKA). Portable infusion pumps allow infusion continuation following hospital discharge, raising the possibility of decreasing hospitalization duration. We therefore used a multicenter, randomized, triple-masked, placebo-controlled study design to test the primary hypothesis that a four-day ambulatory cFNB decreases the time until each of three predefined readiness-for-discharge criteria (adequate analgesia, independence from intravenous opioids, and ambulation ≥ 30 meters) are met following TKA compared with an overnight inpatient-only cFNB. Preoperatively, all patients received a cFNB with perineural ropivacaine 0.2% from surgery until the following morning, at which time they were randomized to either continue perineural ropivacaine (n=39) or switch to normal saline (n=38). Patients were discharged with their cFNB and portable infusion pump as early as postoperative day three. Patients given four days of perineural ropivacaine attained all three criteria in a median (25th–75th percentiles) of 47 (29–69) hours, compared with 62 (45–79) hours for those of the control group (Estimated ratio=0.80, 95% confidence interval: 0.66–1.00; p=0.028). Compared with controls, patients randomized to ropivacaine met the discharge criterion for analgesia in 20 (0–38) vs. 38 (15–64) hours (p=0.009), and intravenous opioid independence in 21 (0–37) vs. 33 (11–50) hours (p=0.061). We conclude that a four-day ambulatory cFNB decreases the time to reach three important discharge criteria by an estimated 20% following TKA compared with an overnight cFNB, primarily by improving analgesia. PMID:20573448
Exercise-Dependent Modulation of Neurourological Health Following Spinal Cord Injury
2014-11-01
Neurobiology, 2Kentucky Spinal Cord Injury Research Center, 3Department of Neurological Surgery, 4Frazier Rehab Institute, University of Louisville...an infusion pump and pressure transducer.24 Behavioral procedures Training paradigm. Training interventions initiated acutely post-SCI may be...proper plantar placement—e.g. complete toe extension, no ankle rotation, and incorporation of forelimb-hindlimb coordination with minimal assistance
Park, Huee Jin; Kim, Kyung Hoon; Lee, Hyuk Jin; Jeong, Eui Cheol; Kim, Kee Won; Suh, Dong In
2015-11-01
Compartment syndrome is a rare but devastating condition that can result in permanent neuromuscular or soft tissue injuries. Extravasation injuries, among the iatrogenic causes of compartment syndrome, occur under a wide variety of circumstances in the inpatient setting. Total parenteral nutrition via a peripheral route is an effective alternative for the management of critically ill children who do not obtain adequate nutrition via the oral route. However, there is an inherent risk of extravasation, which can cause compartment syndrome, especially when detected at a later stage. Herein, we report a rare case of compartment syndrome and skin necrosis due to extravasation, requiring emergency fasciotomy and skin graft in a 7-month-old boy who was treated with peripheral parenteral nutrition via a pressurized infusion pump. Although we cannot estimate the exact time at which extravasation occurred, the extent and degree of the wound suggest that the ischemic insult was prolonged, lasting for several hours. Pediatric clinicians and medical teams should carefully examine the site of insertion of the intravenous catheter, especially in patients receiving parenteral nutrition via a peripheral intravenous catheter with a pressurized infusion pump.
Westphal, Glauco Adrieno
2016-02-01
The disproportion between the supply and demand of transplant organs could be alleviated by improving the quality of clinical management of deceased potential donors. As a large number of donor losses by cardiac arrest occur due to hemodynamic instability, without instituting all essential maintenance measures, it is likely that the application of simplified potential donor maintenance protocols will help to decrease potential donor losses and increase the supply of organs for transplantation. The Ventilation, Infusion and Pumping (VIP) strategy is a mnemonic method that brings together key aspects of the restoration of oxygen delivery to tissues during hemodynamic instability: adequate mechanical Ventilation, volume Infusion and evaluation of heart Pump effectiveness. The inclusion of the additional initials, "P" and "S," refers to Pharmacological treatment and Specificities involved in the etiology of shock. The use of simplified care standards can assist in adhering to essential potential donor management measures. Therefore, using a simplified method as the adapted VIP approach can contribute to improving management standards of potential organ donors and increasing the supply of organs for transplantation. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Matteucci, Elena; Giampietro, Ottavio; Covolan, Vera; Giustarini, Daniela; Fanti, Paolo; Rossi, Ranieri
2015-01-01
Insulin is a life-saving medication for people with type 1 diabetes, but traditional insulin replacement therapy is based on multiple daily subcutaneous injections or continuous subcutaneous pump-regulated infusion. Nonphysiologic delivery of subcutaneous insulin implies a rapid and sustained increase in systemic insulin levels due to the loss of concentration gradient between portal and systemic circulations. In fact, the liver degrades about half of the endogenous insulin secreted by the pancreas into the venous portal system. The reverse insulin distribution has short- and long-term effects on glucose metabolism. Thus, researchers have explored less-invasive administration routes based on innovative pharmaceutical formulations, which preserve hormone stability and ensure the therapeutic effectiveness. This review examines some of the recent proposals from clinical and material chemistry point of view, giving particular attention to patients’ (and diabetologists’) ideal requirements that organic chemistry could meet. PMID:26124635
Sickle cell anemia: the impact of discovery, politics, and business.
Xie, Lai-Hua; Doye, Angelia A; Conley, Eric; Gwathmey, Judith K
2013-11-01
Sickle cell anemia affects 100,000 African Americans. Frequent blood transfusions to prevent stroke lead to fatal iron-overload. Iron chelation with deferoxamine (DFO) requires expensive infusions. In the present study, we explore the feasibility of using a new delivery system for DFO, i.e., targeted liposome entrapped DFO (LDFO). Our results reveal that our novel formulation lowered the dosage requirements by 50%-75%, allowed for less frequent and shorter treatment durations, eliminating the need for a pump and the standard multi-night administration of DFO. In an iron-overloaded rat model, LDFO reduced iron in the liver, and also improved cardiac function. The lower dosage and improved safety profile makes our novel LDFO delivery system a highly desirable new therapy. Meanwhile, this system will also provide an ideal model for studying the mechanism of Fe overload-induced arrhythmias. The political and economic factors related to health care disparities are also discussed.
Melatonin reverses morphine tolerance by inhibiting microglia activation and HSP27 expression.
Lin, Sheng-Hsiung; Huang, Ya-Ni; Kao, Jen-Hsin; Tien, Lu-Tai; Tsai, Ru-Yin; Wong, Chih-Shung
2016-05-01
Melatonin has been reported to attenuate opioid tolerance. In this study, we explored the possible mechanism of melatonin in diminishing morphine tolerance. Two intrathecal (i.t.) catheters were implanted in male Wistar rats for drug delivery. One was linked to a mini-osmotic pump for morphine or saline infusion. On the seventh day, 50μg of melatonin or vehicle was injected through the other catheter instantly after discontinuation of morphine or saline infusion; 3h later, 15μg of morphine or saline was injected. The antinociceptive response was then measured using the tail-flick test every 30min for 120min. The results showed that chronic morphine infusion elicited antinociceptive tolerance and upregulated heat shock protein 27 (HSP27) expression in the dorsal horn of the rat spinal cord. Melatonin pretreatment partially restored morphine's antinociceptive effect in morphine-tolerant rats and reversed morphine-induced HSP27 upregulation. In addition, chronic morphine infusion induced microglial cell activation and was reversed by melatonin treatment. The present study provides evidence that melatonin, acting via inhibiting morphine-induced neuroinflammation, can be useful as a therapeutic adjuvant for patients under long-term opioid treatment for pain relief. Copyright © 2016 Elsevier Inc. All rights reserved.
Blakley, Gregory G; Pohorecky, Larissa A; Benjamin, Daniel
2004-02-01
Compared with the use of classic receptor ligands, antisense oligonucleotides (ASO) targeted at specific central nervous system receptors are an effective alternative in experiments designed to examine the behavioral role of such systems. The nociception/orphaninFQ (N/OFQ) system has been implicated in mediating endocrine function, feeding, stress, pain, anxiety, and the rewarding effects of drugs of abuse. The objective of the current study was to examine whether long-term ASO-induced downregulation of N/OFQ's receptor (NOP) produced changes in endocrine, anxiety, nociception and ethanol's (EtOH's) locomotor activating properties. Male Long Evans rats were implanted with osmotic mini-pumps containing ASO for the NOP receptor. ASO was chronically infused for 26 days and, during this time, multiple behavioral and physiological measurements were conducted. ASO infusion significantly reduced expression of the NOP receptor in brain, confirmed by significant reductions of OFQ-stimulated [(35)S]-GTPgammaS binding in the paraventricular nucleus, prefrontal cortex, and septum. Behavioral changes were observed in ASO-treated animals including higher body temperature, increased water intake, decreased corticosterone (CORT) levels, decreased grooming in the open field, increased tail-flick latency, shorter durations on the open arms of the elevated plus maze, and heightened locomotor activity following EtOH. These behavioral, physiological and endocrine changes are relatively consistent with previous findings with agonists and antagonists for the NOP receptor and, taken together, suggest that ASO-induced downregulation of the NOP receptor is an effective method for studying the N/OFQ system.
Samaranayake, N R; Cheung, S T D; Chui, W C M; Cheung, B M Y
2012-12-01
Healthcare technology is meant to reduce medication errors. The objective of this study was to assess unintended errors related to technologies in the medication use process. Medication incidents reported from 2006 to 2010 in a main tertiary care hospital were analysed by a pharmacist and technology-related errors were identified. Technology-related errors were further classified as socio-technical errors and device errors. This analysis was conducted using data from medication incident reports which may represent only a small proportion of medication errors that actually takes place in a hospital. Hence, interpretation of results must be tentative. 1538 medication incidents were reported. 17.1% of all incidents were technology-related, of which only 1.9% were device errors, whereas most were socio-technical errors (98.1%). Of these, 61.2% were linked to computerised prescription order entry, 23.2% to bar-coded patient identification labels, 7.2% to infusion pumps, 6.8% to computer-aided dispensing label generation and 1.5% to other technologies. The immediate causes for technology-related errors included, poor interface between user and computer (68.1%), improper procedures or rule violations (22.1%), poor interface between user and infusion pump (4.9%), technical defects (1.9%) and others (3.0%). In 11.4% of the technology-related incidents, the error was detected after the drug had been administered. A considerable proportion of all incidents were technology-related. Most errors were due to socio-technical issues. Unintended and unanticipated errors may happen when using technologies. Therefore, when using technologies, system improvement, awareness, training and monitoring are needed to minimise medication errors. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Generic Safety Requirements for Developing Safe Insulin Pump Software
Zhang, Yi; Jetley, Raoul; Jones, Paul L; Ray, Arnab
2011-01-01
Background The authors previously introduced a highly abstract generic insulin infusion pump (GIIP) model that identified common features and hazards shared by most insulin pumps on the market. The aim of this article is to extend our previous work on the GIIP model by articulating safety requirements that address the identified GIIP hazards. These safety requirements can be validated by manufacturers, and may ultimately serve as a safety reference for insulin pump software. Together, these two publications can serve as a basis for discussing insulin pump safety in the diabetes community. Methods In our previous work, we established a generic insulin pump architecture that abstracts functions common to many insulin pumps currently on the market and near-future pump designs. We then carried out a preliminary hazard analysis based on this architecture that included consultations with many domain experts. Further consultation with domain experts resulted in the safety requirements used in the modeling work presented in this article. Results Generic safety requirements for the GIIP model are presented, as appropriate, in parameterized format to accommodate clinical practices or specific insulin pump criteria important to safe device performance. Conclusions We believe that there is considerable value in having the diabetes, academic, and manufacturing communities consider and discuss these generic safety requirements. We hope that the communities will extend and revise them, make them more representative and comprehensive, experiment with them, and use them as a means for assessing the safety of insulin pump software designs. One potential use of these requirements is to integrate them into model-based engineering (MBE) software development methods. We believe, based on our experiences, that implementing safety requirements using MBE methods holds promise in reducing design/implementation flaws in insulin pump development and evolutionary processes, therefore improving overall safety of insulin pump software. PMID:22226258
Catargi, B; Breilh, D; Gin, H; Rigalleau, V; Saux, M C; Roger, P; Tabarin, A
2001-06-01
To compare a non-programmable and a programmable insulin external pump using regular insulin on glycemic stability, the risk of severe hypoglycemia and metabolic control in type 1 diabetic patients. Ten type 1 diabetic patients were involved in a randomized, crossover study comparing two periods of 3 months with continuous subcutaneous insulin infusion (CSII) either with a non-programmable insulin pump or a programmable insulin pump. Comparisons were made among mean blood glucose values before and after meals, at bedtime and at 2: 00 a.m.; the risk of severe hypoglycemia assessed by the low blood glucose index (LBGI); and HbA1c. Mean average blood glucose (BG) measurements were significantly lower with the programmable in comparison with the non-programmable insulin pump (respectively 157+/-78 vs. 165+/-79, p=0.034). While postprandial values for BG were not different between the two pumps, the use of the programmable pump resulted in a significant decrease in mean preprandial BG levels (140+/-68 vs. 150+/-73 mg/dl p=0.039). Conversely mean BG level was lower at 2 a.m. with the non-prgrammable pump (125+/-81 vs. 134 +/-93 mg/dl, p=0.02) but with a higher incidence of hypoglycemia. Mean LBGI was comparable with the two pumps (3.1+/-8.6 vs. 2.8+/-6.9, p=0.1). There was a 0.2% decrease in HbA1c during the programmable pump period that did not reach statistical significance (p=0.37). The present study suggests that programmable external insulin pumps, although more complex and more expensive than non-programmable insulin pumps, significantly reduce fasting glycemia during the day without increasing the risk of severe hypoglycemia and are safer during the night.
Young-Hyman, Deborah L; Peterson, Claire M; Fischer, Sarah; Markowitz, Jessica T; Muir, Andrew B; Laffel, Lori M
2016-07-01
This study evaluated the associations between depressive symptoms, emotion dysregulation and bulimic symptoms in youth with type 1 diabetes (T1D) in the context of the diagnosis and treatment of T1D. Study participants were 103 youth in 2 distinct groups: newly diagnosed (New) or transitioning to pump therapy (continuous subcutaneous insulin infusion [CSII]; "Pump"), who completed questionnaires regarding symptoms of depression, emotion dysregulation, and bulimia. Glycemic control (A1c), height, weight, and questionnaires were evaluated within 10 days of diagnosis (n = 58) or at education/clinic visit before starting insulin utilizing CSII (n = 45). In the newly diagnosed group, only depression accounted for significant variance in bulimia scores (β = .47, P < .01). For the group with disease treatment experience (Pump), but not for the newly diagnosed group (New), greater depressive symptoms and emotion dysregulation were associated with greater bulimic symptoms. Depressive symptoms and emotion dysregulation, an indicator of poor coping/behavioral control, could help explain adoption of disordered eating behaviors in youth with T1D who are transitioning to pump therapy. © 2016 Diabetes Technology Society.
Adaptive control of artificial pancreas systems - a review.
Turksoy, Kamuran; Cinar, Ali
2014-01-01
Artificial pancreas (AP) systems offer an important improvement in regulating blood glucose concentration for patients with type 1 diabetes, compared to current approaches. AP consists of sensors, control algorithms and an insulin pump. Different AP control algorithms such as proportional-integral-derivative, model-predictive control, adaptive control, and fuzzy logic control have been investigated in simulation and clinical studies in the past three decades. The variability over time and complexity of the dynamics of blood glucose concentration, unsteady disturbances such as meals, time-varying delays on measurements and insulin infusion, and noisy data from sensors create a challenging system to AP. Adaptive control is a powerful control technique that can deal with such challenges. In this paper, a review of adaptive control techniques for blood glucose regulation with an AP system is presented. The investigations and advances in technology produced impressive results, but there is still a need for a reliable AP system that is both commercially viable and appealing to patients with type 1 diabetes.
Improving Urogenital Function with Step Training after Spinal Cord Injury
2016-10-01
pump and pressure transducer. Normal saline was infused into the bladder at a rate of 0.25mL/min to evoke voiding contractions [34]. Uro - dynamic data...3 4 5 6 7 8 BB B op en fi el d lo co m ot or sc or e Weeks post-SCI Nontrain Forelimb Train Spontaneous recovery Training began ∗ ∗∗ ∗ Figure
Development of an integrated semi-automated system for in vitro pharmacodynamic modelling.
Wang, Liangsu; Wismer, Michael K; Racine, Fred; Conway, Donald; Giacobbe, Robert A; Berejnaia, Olga; Kath, Gary S
2008-11-01
The aim of this study was to develop an integrated system for in vitro pharmacodynamic modelling of antimicrobials with greater flexibility, easier control and better accuracy than existing in vitro models. Custom-made bottle caps, fittings, valve controllers and a modified bench-top shaking incubator were used. A temperature-controlled automated sample collector was built. Computer software was developed to manage experiments and to control the entire system including solenoid pinch valves, peristaltic pumps and the sample collector. The system was validated by pharmacokinetic simulations of linezolid 600 mg infusion. The antibacterial effect of linezolid against multiple Staphylococcus aureus strains was also studied in this system. An integrated semi-automated bench-top system was built and validated. The temperature-controlled automated sample collector allowed unattended collection and temporary storage of samples. The system software reduced the labour necessary for many tasks and also improved the timing accuracy for performing simultaneous actions in multiple parallel experiments. The system was able to simulate human pharmacokinetics of linezolid 600 mg intravenous infusion accurately. A pharmacodynamic study of linezolid against multiple S. aureus strains with a range of MICs showed that the required 24 h free drug AUC/MIC ratio was approximately 30 in order to keep the organism counts at the same level as their initial inoculum and was about > or = 68 in order to achieve > 2 log(10) cfu/mL reduction in the in vitro model. The integrated semi-automated bench-top system provided the ability to overcome many of the drawbacks of existing in vitro models. It can be used for various simple or complicated pharmacokinetic/pharmacodynamic studies efficiently and conveniently.
A flatness-based control approach to drug infusion for cardiac function regulation
NASA Astrophysics Data System (ADS)
Rigatos, Gerasimos; Zervos, Nikolaos; Melkikh, Alexey
2016-12-01
A new control method based on differential flatness theory is developed in this article, aiming at solving the problem of regulation of haemodynamic parameters, Actually control of the cardiac output (volume of blood pumped out by heart per unit of time) and of the arterial blood pressure is achieved through the administered infusion of cardiovascular drugs, such as dopamine and sodium nitroprusside. Time delays between the control inputs and the system's outputs are taken into account. Using the principle of dynamic extension, which means that by considering certain control inputs and their derivatives as additional state variables, a state-space description for the heart's function is obtained. It is proven that the dynamic model of the heart is a differentially flat one. This enables its transformation into a linear canonical and decoupled form, for which the design of a stabilizing feedback controller becomes possible. The proposed feedback controller is of proven stability and assures fast and accurate tracking of the reference setpoints by the outputs of the heart's dynamic model. Moreover, by using a Kalman Filter-based disturbances' estimator, it becomes possible to estimate in real-time and compensate for the model uncertainty and external perturbation inputs that affect the heart's model.
A critical review and analysis of ethical issues associated with the artificial pancreas.
Quintal, A; Messier, V; Rabasa-Lhoret, R; Racine, E
2018-04-25
The artificial pancreas combines a hormone infusion pump with a continuous glucose monitoring device, supported by a dosing algorithm currently installed on the pump. It allows for dynamic infusions of insulin (and possibly other hormones such as glucagon) tailored to patient needs. For patients with type 1 diabetes the artificial pancreas has been shown to prevent more effectively hypoglycaemic events and hyperglycaemia than insulin pump therapy and has the potential to simplify care. However, the potential ethical issues associated with the upcoming integration of the artificial pancreas into clinical practice have not yet been discussed. Our objective was to identify and articulate ethical issues associated with artificial pancreas use for patients, healthcare professionals, industry and policymakers. We performed a literature review to identify clinical, psychosocial and technical issues raised by the artificial pancreas and subsequently analysed them through a common bioethics framework. We identified five sensitive domains of ethical issues. Patient confidentiality and safety can be jeopardized by the artificial pancreas' vulnerability to security breaches or unauthorized data sharing. Public and private coverage of the artificial pancreas could be cost-effective and warranted. Patient selection criteria need to ensure equitable access and sensitivity to patient-reported outcomes. Patient coaching and support by healthcare professionals or industry representatives could help foster realistic expectations in patients. Finally, the artificial pancreas increases the visibility of diabetes and could generate issues related to personal identity and patient agency. The timely consideration of these issues will optimize the technological development and clinical uptake of the artificial pancreas. Copyright © 2018. Published by Elsevier Masson SAS.
Gallagher, Erin; Minn, Il; Chambers, Janice E; Searson, Peter C
2016-07-11
Current therapies for organophosphate poisoning involve administration of oximes, such as pralidoxime (2-PAM), that reactivate the enzyme acetylcholinesterase. Studies in animal models have shown a low concentration in the brain following systemic injection. To assess 2-PAM transport, we studied transwell permeability in three Madin-Darby canine kidney (MDCKII) cell lines and stem cell-derived human brain microvascular endothelial cells (BC1-hBMECs). To determine whether 2-PAM is a substrate for common brain efflux pumps, experiments were performed in the MDCKII-MDR1 cell line, transfected to overexpress the P-gp efflux pump, and the MDCKII-FLuc-ABCG2 cell line, transfected to overexpress the BCRP efflux pump. To determine how transcellular transport influences enzyme reactivation, we developed a modified transwell assay where the inhibited acetylcholinesterase enzyme, substrate, and reporter are introduced into the basolateral chamber. Enzymatic activity was inhibited using paraoxon and parathion. The permeability of 2-PAM is about 2 × 10(-6) cm s(-1) in MDCK cells and about 1 × 10(-6) cm s(-1) in BC1-hBMECs. Permeability is not influenced by pre-treatment with atropine. In addition, 2-PAM is not a substrate for the P-gp or BCRP efflux pumps. The low permeability explains poor brain penetration of 2-PAM and therefore the slow enzyme reactivation. This elucidates one of the reasons for the necessity of sustained intravascular (IV) infusion in response to organophosphate poisoning.
NASA Astrophysics Data System (ADS)
Carroll, R. W. H.; Pohll, G.; Benedict, J.; Felling, R.
2016-12-01
Many arid and semi-arid agricultural systems of the Great Basin in the western United States depend on supplemental groundwater pumping to augment diminished surface water flows during periods of drought. As droughts become longer and more severe in the region, unprecedented drawdown in these aquifer systems has occurred with legal and environmental implications on both surface and groundwater. The Walker River in the Great Basin supports extensive agriculture in the region and is the sole perennial stream to one of the few desert terminal lakes in North America. Continuous declines in the lake have spurred extensive research into management options to balance demands of agriculture and increase water deliveries to the lake. Smith and Mason Valleys are important agricultural centers within the Walker Basin. In 2015 the region entered its fifth year of drought and both valleys were the focus of curtailment orders to restrict the use of supplemental groundwater rights. To aid management decisions, hydrologic models were developed that simulate complex feedbacks between surface diversions, crop consumptive needs, groundwater recharge, return flow, and groundwater-surface water interactions. Demand-driven pumping that incorporates priority dates and maximum duty allocations are directly input to the hydrologic model to allow an assessment of groundwater curtailment options under a variety of drought scenarios to meet targeted water levels and downstream conveyance of surface water in a legally defensible framework. Hydrologic results using a sliding scale approach to priority based curtailment are presented in the arena of stakeholder participation and response.
Soltani, Ghasem; Jahanbakhsh, Saeed; Tashnizi, Mohammad Abbasi; Fathi, Mehdi; Amini, Shahram; Zirak, Nahid; Sheybani, Shima
2017-01-01
Background Arrhythmia occurring during and after surgery is one of the major complications in open-heart surgery. Dexmedetomidine is an intravenous alpha-2 agonist and very specific short-acting drug to protect the various organs against ischemic injuries and blood reflow. However, the effect of dexmedetomidine for preventing intraoperative heart arrhythmias has not been recognized. Objective This study aimed to determine the effect of dexmedetomidine on the incidence rate of heart arrhythmias and anesthetic required in off-pump coronary artery bypass surgery. Methods This randomized clinical trial was conducted on patients who were candidates for off-pump coronary artery bypass referring to Imam Reza Hospital of Mashhad, Iran, from July 2016 through January 2017. The patients were randomly assigned to two groups of intervention (infusion of 0.5 mcg/kg/h dexmedetomidine together with induction followed by infusion of 0.5 mcg/kg/h by the end of the surgery) or control (saline infusion). Mean arterial pressure (MAP) and heart rate (HR) were measured before induction, during surgery operation and ICU admission. Data were analyzed by SPSS version 18 using Chi Square and independent-samples t-test. Results A total of 76 patients with a mean age of 59.8 ± 8.2 years (in two groups of 38) were studied. The two groups had no statistically significant difference in terms of background variables. The MAP and HR values before induction, during surgery and ICU admission were significantly higher in the control group than in the intervention group (p=0.001). Out of the studied arrhythmias, the values of PAC (55.2% vs. 15.7%), PVC (81.5% vs. 21.0%), AF (26.3% vs. 7.8%), VTAC (21.0% vs. 2.6%) were significantly lower in dexmedetomidine group (p=0.001). Conclusion It seems that dexmedetomidine administration during induction and surgery can cause significant reduction in most of the common arrhythmias in off-pump coronary bypass surgery. The use of dexmedetomidine maintains MAP and HR at significantly lower values, and changes compared to the control group as well as reduces the need for anesthetic compounds. Trial Registration The present study has been registered at the Iranian Registry of Clinical Trials (www.IRCT.IR) with a code of IRCT2016072413159N9 before starting the study. Founding This study was fully sponsored by the Research Deputy at Mashhad University of Medical Sciences, Iran (grant number 941413). PMID:29238500
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
Lo, Po-Han; Tsou, Mei-Yung; Chang, Kuang-Yi
2015-09-01
Patient-controlled epidural analgesia (PCEA) is commonly used for pain relief after total knee arthroplasty (TKA). This study aimed to model the trajectory of analgesic demand over time after TKA and explore its influential factors using latent curve analysis. Data were retrospectively collected from 916 patients receiving unilateral or bilateral TKA and postoperative PCEA. PCEA demands during 12-hour intervals for 48 hours were directly retrieved from infusion pumps. Potentially influential factors of PCEA demand, including age, height, weight, body mass index, sex, and infusion pump settings, were also collected. A latent curve analysis with 2 latent variables, the intercept (baseline) and slope (trend), was applied to model the changes in PCEA demand over time. The effects of influential factors on these 2 latent variables were estimated to examine how these factors interacted with time to alter the trajectory of PCEA demand over time. On average, the difference in analgesic demand between the first and second 12-hour intervals was only 15% of that between the first and third 12-hour intervals. No significant difference in PCEA demand was noted between the third and fourth 12-hour intervals. Aging tended to decrease the baseline PCEA demand but body mass index and infusion rate were positively correlated with the baseline. Only sex significantly affected the trend parameter and male individuals tended to have a smoother decreasing trend of analgesic demands over time. Patients receiving bilateral procedures did not consume more analgesics than their unilateral counterparts. Goodness of fit analysis indicated acceptable model fit to the observed data. Latent curve analysis provided valuable information about how analgesic demand after TKA changed over time and how patient characteristics affected its trajectory.
Goyal, Nitin; McKenzie, James; Sharkey, Peter F; Parvizi, Javad; Hozack, William J; Austin, Matthew S
2013-01-01
Postoperative pain after total knee arthroplasty remains one of the most important challenges facing patients undergoing this surgery. Providing a balance of adequate analgesia while limiting the functional impact of regional anesthesia and minimizing opioid side effects is critical to minimize adverse events and improve patient satisfaction. We asked whether bupivacaine delivered through an elastomeric device decreases the (1) patients' perception of pain after TKA; (2) narcotic consumption; and (3) narcotic-related side effects as compared with a placebo. In this prospective, double-blind, placebo-controlled study, all patients received standardized regional anesthesia, a preemptive and multimodal analgesic protocol, and a continuous intraarticular infusion at 5 mL/hour through an elastomeric infusion pump. The patients were randomized to receive either an infusion pump filled with (1) 300 mL of 0.5% bupivacaine, the experimental group (n = 75); or (2) 300 mL of 0.9% normal saline solution, the control group (n = 75). Data concerning postoperative pain levels through a visual analog scale, postoperative opioid consumption, opioid-related side effects, and complications were collected and analyzed. Patients in the experimental group receiving the bupivacaine reported a reduction in pain levels in highest, lowest, and current visual analog scale scores compared with the placebo group on the first postoperative day and highest visual analog scale score on postoperative Day 2 along with a 33% reduction in opioid consumption on postoperative Day 2 and a 54% reduction on postoperative Day 3. In patients undergoing TKA, continuous intraarticular analgesia provided an effective adjunct for pain relief in the immediate postoperative period without the disadvantages encountered with other analgesic methods.
Papargyri, Panagiota; Ojeda Rodríguez, Sylvie; Corrales Hernández, Juan José; Mories Álvarez, María Teresa; Recio Córdova, José María; Delgado Gómez, Manuel; Sánchez Marcos, Ana Isabel; Iglesias López, Rosa Ana; Herrero Ruiz, Ana; Beaulieu Oriol, Myriam; Miralles García, José Manuel
2014-03-01
This work reports the experience with use of continuous subcutaneous insulin infusion (CSII) in 112 type 1 diabetic patients followed up for 7 years and previously treated with multiple daily insulin injections (MDII). A retrospective, observational study in 112 patients with diabetes mellitus treated with CSII from 2005 to 2012, previously treated with MDII and receiving individualized diabetic education with a specific protocol. Variables analyzed included: prevalence of the different indications of pump treatment; mean annual HbA1c and fructosamine values before and after CSII treatment; and hypoglycemia frequency and symptoms. The most common reason for pump treatment was brittle diabetes (74.1%), followed by frequent or severe hypoglycemia or hypoglycemia unawareness (44.6%). Other indications were irregular food intake times for professional reasons (20.2%), dawn phenomenon (15.7%), pregnancy (12.3%), requirement of very low insulin doses (8.9%), and gestational diabetes (0.9%). HbA1c decreased by between 0.6% and 0.9%, and fructosamine by between 5.1% and 12.26%. Nine percent of patients experienced hypoglycemia weekly, 24% every two weeks, and 48% monthly. No hypoglycemia occurred in 19% of patients. Only 10% had neuroglycopenic symptoms. Hypoglycemia unawareness was found in 21%. Hypoglycemia was more common at treatment start, and its frequency rapidly decreased thereafter. CSII therapy provides a better glycemic control than MDII treatment. Specific patient training and fine adjustment of insulin infusion doses are required to prevent hypoglycemic episodes, which are the most common complications, mainly at the start of treatment. Copyright © 2013 SEEN. Published by Elsevier Espana. All rights reserved.
[Morphine-antiemetics mixtures for continuous subcutaneous infusion in terminal cancer].
Ottesen, S; Monrad, L
1992-05-30
Simultaneous pain, nausea and vomiting are not uncommon in terminal suffering requiring treatment with various compounds of analgesics and antiemetics. At Baerum Hospital the pump reservoirs for continuous, subcutaneous drug delivery are routinely filled by the hospital pharmacist. We examined the physico-chemical stability of various concentrations of mixtures of morphine-metoclopramide and morphine-metoclopramide-haloperidol at 25 degrees C. We found good stability for at least seven days. Addition of haloperidol seems to reduce stability. Plain morphine-haloperidol solutions are unstable. Split products were not found in any of the mixtures. We also examined the osmolality of current clinical compounds, focusing on local irritant effect at the infusion site. All solutions except for one with a high concentration of haloperidol were found to be close to isoosmolarl.
Obseving Nurse Interaction With Infusion Pump Technologies
2005-01-01
24 Observations of the medication administration process , as described below, were performed to provide data to the FMEA team on nursing practice...involves an FMEA of the medication administration process using the observation data as input into the assessment process .29 One use of the...invaluable to the FMEA team in many ways. First, it allowed for an unbiased and nonjudgmental look at the actual nursing processes in place, as
Use of di(2-ethylhexyl)phthalate-containing infusion systems increases the risk for cholestasis.
von Rettberg, Heike; Hannman, Torsten; Subotic, Ulrike; Brade, Joachim; Schaible, Thomas; Waag, Karl Ludwig; Loff, Steffan
2009-08-01
Most polyvinylchloride infusion systems are plasticized with up to 60% of di(2-ethylhexyl)phthalate (DEHP). DEHP is easily extracted from the tubing by total parenteral nutrition (TPN) solutions and has been shown to have toxic effects on various organ systems including the liver in animals and humans. A role was postulated for DEHP in the development of hepatobiliary dysfunction in premature and newborn infants receiving parenteral nutrition, and the incidence of cholestasis was investigated after changing from polyvinylchloride infusion systems to polyvinylchloride-free infusion systems. Two 3-year periods from 1998 to 2004 were investigated retrospectively before and after changing from polyvinylchloride to polyvinylchloride-free infusion systems in our department. This resulted in 1 group of 30 patients treated with polyvinylchloride lines and a second group of 46 patients treated with polyvinylchloride-free lines. The 2 groups were examined for the incidence of cholestasis and other possible contributing factors. Statistics were performed by using SAS software (SAS Institute, Cary, NC). After changing infusion systems, the incidence of cholestasis dropped from 50% to 13%. Using DEHP-plasticized polyvinylchloride infusion systems for TPN increased the risk for cholestasis by a factor of 5.6. The use of polyvinylchloride lines correlated strongly with the development of TPN-associated cholestasis (P = .0004). Using DEHP-containing polyvinylchloride infusions systems contributes to the development of cholestasis. Therefore, the use of DEHP-free infusion systems for TPN is recommended, especially in premature and newborn infants.
Improving the anesthetic process by a fuzzy rule based medical decision system.
Mendez, Juan Albino; Leon, Ana; Marrero, Ayoze; Gonzalez-Cava, Jose M; Reboso, Jose Antonio; Estevez, Jose Ignacio; Gomez-Gonzalez, José F
2018-01-01
The main objective of this research is the design and implementation of a new fuzzy logic tool for automatic drug delivery in patients undergoing general anesthesia. The aim is to adjust the drug dose to the real patient needs using heuristic knowledge provided by clinicians. A two-level computer decision system is proposed. The idea is to release the clinician from routine tasks so that he can focus on other variables of the patient. The controller uses the Bispectral Index (BIS) to assess the hypnotic state of the patient. Fuzzy controller was included in a closed-loop system to reach the BIS target and reject disturbances. BIS was measured using a BIS VISTA monitor, a device capable of calculating the hypnosis level of the patient through EEG information. An infusion pump with propofol 1% is used to supply the drug to the patient. The inputs to the fuzzy inference system are BIS error and BIS rate. The output is infusion rate increment. The mapping of the input information and the appropriate output is given by a rule-base based on knowledge of clinicians. To evaluate the performance of the fuzzy closed-loop system proposed, an observational study was carried out. Eighty one patients scheduled for ambulatory surgery were randomly distributed in 2 groups: one group using a fuzzy logic based closed-loop system (FCL) to automate the administration of propofol (42 cases); the second group using manual delivering of the drug (39 cases). In both groups, the BIS target was 50. The FCL, designed with intuitive logic rules based on the clinician experience, performed satisfactorily and outperformed the manual administration in patients in terms of accuracy through the maintenance stage. Copyright © 2018 Elsevier B.V. All rights reserved.
Canis, Martin; Mack, Brigitte; Gires, Olivier; Maurer, Martin H; Kuschinsky, Wolfgang; Duembgen, Lutz; Duelli, Roman
2009-08-01
Chronic administration of nicotine is followed by a general stimulation of brain metabolism that results in a distinct increase of glucose transport protein densities for Glut1 and Glu3, and local cerebral glucose utilization (LCGU). This increase of LCGU might be paralleled by an enhanced production of lactate. Therefore, the question arose as to whether chronic nicotine infusion is accompanied by increased local densities of monocarboxylate transporter MCT1 in the brain. Secondly, we inquired whether LCGU might be correlated with local densities of MCT1 during normal conditions and after chronic nicotine infusion. Nicotine was given subcutaneously for 1 week by osmotic mini-pumps and local densities of MCT1 were measured by immunoautoradiographic methods in cryosections of rat brains. MCT1 density was significantly increased in 21 of 32 brain structures investigated (median increase 15.0+/-3.6%). Immunohistochemical stainings of these substructures revealed an over-expression of MCT1 within endothelial cells and astrocytes of treated animals. A comparison of 23 MCT1 densities with LCGU measured in the same structures in a previous study revealed a partial correlation between both parameters under control conditions and after chronic nicotine infusion. 10 out of 23 brain areas, which showed a significant increase of MCT1 density due to chronic nicotine infusion, also showed a significant increase of LCGU. In summary, our data show that chronic nicotine infusion induces a moderate increase of local and global density of MCT1 in defined brain structures. However, in terms of brain topologies and substructures this phenomenon did partially match with increased LCGU. It is concluded that MCT1 transporters were upregulated during chronic nicotine infusion at the level of brain substructures and, at least partially, independently of LCGU.
Tan, Tricia; Behary, Preeshila; Tharakan, George; Minnion, James; Al-Najim, Werd; Albrechtsen, Nicolai J. Wewer; Holst, Jens J.
2017-01-01
Background: Roux-en-Y gastric bypass (RYGB) surgery is currently the most effective treatment of obesity, although limited by availability and operative risk. The gut hormones Glucagon-like peptide-1 (GLP-1), Peptide YY (PYY), and Oxyntomodulin (OXM) are elevated postprandially after RYGB, which has been postulated to contribute to its metabolic benefits. Objective: We hypothesized that infusion of the three gut hormones to achieve levels similar to those encountered postprandially in RYGB patients might be effective in suppressing appetite. The aim of this study was to investigate the effect of a continuous infusion of GLP-1, OXM, and PYY (GOP) on energy intake and expenditure in obese volunteers. Methods: Obese volunteers were randomized to receive an infusion of GOP or placebo in a single-blinded, randomized, placebo-controlled crossover study for 10.5 hours a day. This was delivered subcutaneously using a pump device, allowing volunteers to remain ambulatory. Ad libitum food intake studies were performed during the infusion, and energy expenditure was measured using a ventilated hood calorimeter. Results: Postprandial levels of GLP-1, OXM, and PYY seen post RYGB were successfully matched using 4 pmol/kg/min, 4 pmol/kg/min, and 0.4 pmol/kg/min, respectively. This dose led to a mean reduction of 32% in food intake. No significant effects on resting energy expenditure were observed. Conclusion: This is, to our knowledge, the first time that an acute continuous subcutaneous infusion of GOP, replicating the postprandial levels observed after RYGB, is shown to be safe and effective in reducing food intake. This data suggests that triple hormone therapy might be a useful tool against obesity. PMID:28379519
Ordia, Joe I; Fischer, Edward; Adamski, Ellen; Chagnon, Kimberly G; Spatz, Edward L
2002-01-01
We began this study to determine the efficacy and safety of intrathecal baclofen (ITB) delivered by a programmable pump for the treatment of severe spasticity of spinal cord origin. One hundred fifty two patients with severe spasticity of spinal origin, refractory to oral baclofen, or who experienced intolerable side-effects were given a test dose of ITB. Only those who had a satisfactory response were considered to be appropriate for pump implantation. All but one of the 152 patients had a satisfactory response, and the pump was implanted in 131 patients. Pre- and postoperative spasticity scores were compared and analyzed. The mean Ashworth score for rigidity decreased from 4.2 preoperatively to 1.3 (p < 0.0005) on ITB. The spasm score decreased from a mean of 3.4 to 0.6 (p < 0.0005). Reduction of spasticity resulted in improved levels of physical activity, decreased pain, and augmentation of sleep. Drug-related complications included constipation, muscular hypotonia, urinary retention, erectile dysfunction, nausea, dizziness, drowsiness, hypotension and bradycardia as well as tolerance to baclofen. Some patients experienced post-spinal puncture headaches. Catheter-related problems included occlusions, breaks, punctures, and dislodgments. Superficial pump pocket infection, pocket erosion, cerebrospinal fluid (CSF) leak, post-spinal puncture headache, and meningitis were some of the procedure-related complications. Two pumps flipped and another pump valve was stuck. We conclude that long-term intrathecal baclofen by an implanted programmable pump is a safe and effective method of treating severe intractable spinal spasticity.
Miller, Timothy; Pestronk, Alan; David, William; Rothstein, Jeffrey; Simpson, Ericka; Appel, Stanley H.; Andres, Patricia L.; Mahoney, Katy; Allred, Peggy; Alexander, Katie; Ostrow, Lyle W.; Schoenfeld, David; Macklin, Eric A.; Norris, Daniel A.; Manousakis, Georgios; Crisp, Matthew; Smith, Richard; Bennett, C.F.; Bishop, Kathie; Cudkowicz, Merit E
2013-01-01
Objective To evaluate the safety, tolerability, and pharmacokinetics of an antisense oligonucleotide designed to inhibit SOD1 expression (ISIS 333611) following intrathecal administration in patients with SOD1-related familial amyotrophic lateral sclerosis (ALS). Background Mutations in SOD1 cause 13% of familial ALS. In animal studies, ISIS 333611 delivered to the cerebrospinal fluid (CSF) distributed to the brain and spinal cord, decreased SOD1 mRNA and protein levels in spinal cord tissue, and prolonged survival in the SOD1G93A rat ALS model. Methods In a randomized, placebo controlled Phase 1 trial, ISIS 333611 was delivered by intrathecal infusion using an external pump over 11.5 hours at increasing doses to four cohorts of eight SOD1 positive ALS subjects (randomized 6 drug: 2 placebo/cohort). Subjects were allowed to re-enroll in subsequent cohorts. Safety and tolerability assessments were made during the infusion and periodically over 28 days following the infusion. CSF and plasma drug levels were measured. Findings No dose-limiting toxicities were identified at doses up to 3.0 mg. No safety or tolerability concerns related to ISIS 333611 were identified. There were no serious adverse events (AEs) in ISIS 333611-treated subjects. Re-enrollment and re-dosing of subjects with ISIS 333611 was also well tolerated. Dose-dependent CSF and plasma concentrations were observed. Interpretation In this first clinical study to report intrathecal delivery of an antisense oligonucleotide, ISIS 333611 was well tolerated when administered as an intrathecal infusion in subjects with SOD1 familial ALS. CSF and plasma drug levels were consistent with levels predicted from preclinical studies. These results suggest that antisense oligonucleotide delivery to the central nervous system may be a feasible therapeutic strategy for neurological disorders. Source of funding ALS Association, Muscular Dystrophy Association, Isis Pharmaceuticals PMID:23541756
French, J. Tyler; Goins, Beth; Saenz, Marcela; Li, Shihong; Garcia-Rojas, Xavier; Phillips, William T.; Otto, Randal A.; Bao, Ande
2010-01-01
Purpose Minimally invasive interventional cancer therapy of drug-carrying lipid nanoparticles (liposomes) via convection enhanced delivery generally applied by the use of an infusion pump can increase intratumoral drug concentration and retention while facilitating broad distribution throughout solid tumors. We investigated the utility of liposome-carrying β-emitting radionuclides to treat head and neck cancer in nude rats by direct intratumoral infusion. Methods Four groups of nude rats were subcutaneously inoculated with human tongue cancer cells. After tumors reached an average size of 1.6 cm3, the treatment group received an intratumoral infusion of liposomal rhenium-186 (186Re) (185 MBq (5 mCi)/cm3 tumor). Three control groups were intratumorally infused with either, 1) unlabeled liposomes, 2) unencapsulated 186Re-perrhenate, or 3) unencapsulated intermediate 186Re-compound (186Re-BMEDA). In vivo distribution of 186Re-activity was measured by planar gamma camera imaging. Tumor therapy and toxicity were assessed by measurements of tumor size, body weight, and hematology. Results Average tumor volume of the 186Re-liposome group on post-treatment day-14 decreased to 87.7±20.1%, while tumor volumes increased to 395.0% - 514.4% on average in other three groups (P<0.001 vs 186Re-liposome group). 186Re-liposomes provided much higher intratumoral retention of 186Re-activity, resulting in an average tumor radiation absorbed dose of 526.3±93.3 Gy, whereas 186Re-perrhenate and 186Re-BMEDA groups had only 3.3±1.2 and 13.4±9.2 Gy tumor doses respectively. No systemic toxicity was observed. Conclusion Liposomal 186Re effectively treated the head and neck cancer with minimal side effects after convection enhanced interventional delivery. These results suggest the potential of liposomal 186Re for clinical application in interventional therapy of cancer. PMID:20478719
A new venous infusion path monitoring system utilizing electrostatic induced potential.
Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Caldwell, W Morton
2008-01-01
A new venous infusion pathway monitoring system has been developed for hospital and home use. The system consists of linear and digital integrated circuits and a low-power 8-bit single chip microcomputer which constantly monitors the infusion pathway intactness. A 330 kHz AC voltage, which is induced on the patient's body by electrostatic coupling from a 330 kHz pulse oscillator, can be recorded by main and reference electrodes wrapped around the infusion polyvinyl chloride tube. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltages and alerts the nursing station, via the nurse call system or PHS (personal handy phone system).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1982-01-01
Foam spray equipment and materials for dust suppression on longwall double drum shearer faces have been procured. This equipment includes metering pumps, foam generators and mounting brackets, foam solutions, flow meters, real time and gravimetric sampling equipment, hoses and valve banks. Initial tests have been conducted in the laboratory with three types of generators and five types of foam solutions. Based on these tests, Senior Conflow's cluster spray and Onyx Chemical Company's millifoam solution have been selected. For pumping foam solution to the shearer, Jon Bean's 2 hp, 120 VAC single-phase ceramic lined piston pump has been selected. For fieldmore » tests, equipment has been installed underground in Dobbin mine in Upper Freeport seam on Eickhoff EDW 300 double drum shearer. Foamspray tests have been conducted. Real time and gravimetric dust samples have been collected. Real time sampling results indicate a dust level reduction of up to 37 percent with foam spray compared to the base case of water sprays.« less
Morin, Roger H.; Olsen, Harold W.; Nelson, Karl R.; Gill, James D.
1989-01-01
A graphical method has been developed for determining the coefficient of consolidation from the transient phases of a flow-pump permeability test. The flow pump can be used to infuse fluid into or withdraw fluid from a laboratory sediment specimen at a constant volumetric rate in order to obtain data that can be used to calculate permeability using Darcy's law. Representative type-curve solutions to the associated forced-flow and pressure-decay models are derived. These curves provide the basis for graphically evaluating the permeability k, the coefficient of consolidation cv, and the coefficient of volume change mv. The curve-matching technique is easy and rapid. Values of k, cv and mv for a laterally confined kaolinite specimen were determined by this graphical method and appear to be in reasonably good agreement with numerically derived estimates (within 20%). Discrepancies between the two sets of results seem to be largely a function of data quality.
Pre-Clinical Testing of New Hydroxybutyrate Analogues
2011-07-01
complex I and II sites. Several years ago, we evaluated the use of ketone bodies as secondary sources of energy for mitochondria compromised due to...hydroxybutyrate (DβHB), a ketone body normally produced by hepatocytes and astrocytes and infused via Alzet pump, protected the substantia nigra...crisis in the neurons . In an earlier study, bypassing this complex I deficiency using D-- hydroxybutyrate (DHB) in the MPTP (1-methyl-4-phenyl-1,2,3,6
A new infusion pathway monitoring system utilizing electrostatic induced potential.
Maki, Hiromichi; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Ninomiya, Ishio; Sada, Kouji; Hamada, Shingo; Hahn, Alien W; Caldwell, W Morton
2006-01-01
We have developed a new infusion pathway monitoring system employing linear integrated circuits and a low-power 8-bit single chip microcomputer. The system is available for hospital and home use and it constantly monitors the intactness of the pathway. The sensor is an electro-conductive polymer electrode wrapped around the infusion polyvinyl chloride infusion tube. This records an AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltage and alerts the nursing station, via the nurse call system or PHS (personal handy phone System).
Thabit, Hood; Hovorka, Roman
2016-01-01
Continuous subcutaneous insulin infusion (CSII) therapy is currently accepted as a treatment strategy for type 1 diabetes. Transition from multiple daily injection therapy (MDI; including basal-bolus regimens) to CSII is based on expectations of better metabolic control and fewer hypoglycaemic events. Evidence to date has not been always conclusive. Evidence for CSII and MDI in terms of glycaemic control, hypoglycaemia and psychosocial outcomes is reviewed in the adult and paediatric population with type 1 diabetes. Findings from studies on threshold-based insulin pump suspension and predictive low glucose management (PLGM) are outlined. Limitations of current CSII application and future technological developments are discussed. Glycaemic control and quality of life (QOL) may be improved by CSII compared to MDI depending on baseline HbA1c and hypoglycaemia rates. Future studies are expected to provide evidence on clinical and cost effectiveness in those who will benefit the most. Training, structured education and support are important to benefit from CSII. Novel technological approaches linking continuous glucose monitoring (CGM) and CSII may help mitigate against frequent hypoglycaemia in those at risk. Development of glucose-responsive automated closed-loop insulin delivery systems may reduce the burden of disease management and improve outcomes in type 1 diabetes.
[Home anti-cancer therapy with a venous port].
Muto, A; Ashino, Y; Miyazawa, M; Sato, M; Kanno, A; Kawahara, Y; Fujita, Y; Matsushiro, T
2000-12-01
Home anti-cancer chemotherapy and palliation in the terminal stage were performed for patients with advanced cancer of the digestive system, using a venous port implanted beneath the skin via the subclavian vein. Patients under 75 years of age (5 with esophageal, 61 gastric, 59 colorectal, 5 cholangio, 5 pancreatic, 1 hepatic and 1 ileal cancer) were treated. With two portable balloon pumps, continuous intravenous infusion of 5-FU (300 or 400 mg/body/day) combined low-dose injection of cisplatin (5 mg/body/day) was continued for 10 days, and repeated 3 times for 6 weeks. The response rate was 17.9% in 78 patients according to valuation of the tumor mass. In 119 patients also undergoing a tumor marker evaluation, an effect was seen in 26.1%. No severe side effects such as renal dysfunction or bone marrow suppression were seen, and no special infusion was needed. Therefore, such treatment can be continued for a long time. Use of a venous port should make easy the switchover to HPN and the amelioration of the symptoms of the terminal stage, such as pain, and helps patients cope with the worry. Therefore, the present technique is useful in a series of cancer treatments including surgery, chemotherapy and the amelioration of symptoms.
Type of homogenization and fat loss during continuous infusion of human milk.
García-Lara, Nadia Raquel; Escuder-Vieco, Diana; Alonso Díaz, Clara; Vázquez Román, Sara; De la Cruz-Bértolo, Javier; Pallás-Alonso, Carmen Rosa
2014-11-01
Substantial fat loss may occur during continuous feeding of human milk (HM). A decrease of fat loss has been described following homogenization. Well-established methods of homogenization of HM for routine use in the neonatal intensive care unit (NICU) would be desirable. We compared the loss of fat based on the use of 3 different methods for homogenizing thawed HM during continuous feeding. Sixteen frozen donor HM samples were thawed, homogenized with ultrasound and separated into 3 aliquots ("baseline agitation," "hourly agitation," and "ultrasound"), and then frozen for 48 hours. Aliquots were thawed again and a baseline agitation was applied. Subsequently, aliquots baseline agitation and hourly agitation were drawn into a syringe, while ultrasound was applied to aliquot ultrasound before it was drawn into a syringe. The syringes were loaded into a pump (2 mL/h; 4 hours). At hourly intervals the hourly agitation infusion was stopped, the syringe was disconnected and gently shaken. During infusion, samples from the 3 groups were collected hourly for analysis of fat and caloric content. The 3 groups of homogenization showed similar fat content at the beginning of the infusion. For fat, mean (SD) hourly changes of -0.03 (0.01), -0.09 (0.01), and -0.09 (0.01) g/dL were observed for the hourly agitation, baseline agitation, and ultrasound groups, respectively. The decrease was smaller for the hourly agitation group (P < .001). When thawed HM is continuously infused, a smaller fat loss is observed when syringes are agitated hourly versus when ultrasound or a baseline homogenization is used. © The Author(s) 2014.
Comparison of 20-, 23-, and 25-gauge air infusion forces.
Machado, Leonardo Martins; Magalhães, Octaviano; Maia, Mauricio; Rodrigues, Eduardo B; Farah, Michel Eid; Ismail, Kamal A R; Molon, Leandro; Oliveira, Danilo A
2011-11-01
To determine and compare 20-, 23-, and 25-gauge retinal infusion air jet impact pressure (force per unit area) in an experimental setting. Experimental laboratory investigation. Infusion cannulas were connected to a compressed air system. A controlled valve mechanism was used to obtain increasing levels of infusion pressure. Each infusion tube was positioned in front of a manual transducer to measure force. Impact pressure was calculated using known formulas in fluid dynamics. The 20-gauge infusion jet showed similar impact pressure values compared with the 23-gauge infusion jet. Both showed higher levels than the 25-gauge infusion jet. This was because of the smaller jet force for the 25-gauge system. In this experimental study, both the 23- and the 20-gauge air infusion jet showed higher impact pressure values compared with the 25-gauge air infusion jet. This could be of concern regarding air infusion during 23-gauge vitrectomy since retinal damage has been shown in standard-gauge surgeries.
Effect of infused prostaglandin F 2 on hormonal levels during early pregnancy.
Wentz, A C; Jones, G S; Graeber, J
1972-12-01
In light of the theory of prostaglandin (PG) mechanism of action as removal of a progesterone block mediating myometrial stimulation, the effect of PGF2alpha on hormonal patterns was analyzed in 8 patients between 11.5 and 18.5 weeks of gestation. PGF2 alpha was administered intravenously by pump and blood samples were drawn hourly during the first 12 hours and every 2 hours thereafter until abortion occurred. Serum estradiol (2) and estriol (E3) were assayed by radioimmunassay, as was plasma progesteronep. 2 patients had missed abortions; 5 of the 6 remaining patients aborted successfully. The remaining patient of 12 weeks gestation failed to abort. Missed abortion patients had absence of detectible E3 in serum, and E2 and P values were decreased 50%. 3 of 5 successful terminations showed decreases in E3 within first 4 infusion hours and aborted in 17 hours. A 4th patient showed a precipitous E3 drop at 16 infusion hours and aborted at 26 hours. 1 patient showed little E3 change until after abortion, and then it was a 50% decrease. Serum P declined in all 5 successful terminations. E2 values reduced within 4-8 hours before abortion and after infusion. The authors suggest that these findins show a direct effect of PGF2 alpha on steroidogenesis.
Cheung, Carlos Chun Ho; Soon, Choong Yee; Chuang, Chia-Lin; Phillips, Anthony R J; Zhang, Shaoping; Cooper, Garth J S
2015-09-01
Diabetes impairs copper (Cu) regulation, causing elevated serum Cu and urinary Cu excretion in patients with established cardiovascular disease; it also causes cardiomyopathy and chronic cardiac impairment linked to defective Cu homeostasis in rats. However, the mechanisms that link impaired Cu regulation to cardiac dysfunction in diabetes are incompletely understood. Chronic treatment with triethylenetetramine (TETA), a Cu²⁺-selective chelator, improves cardiac function in diabetic patients, and in rats with heart disease; the latter displayed ∼3-fold elevations in free Cu²⁺ in the coronary effluent when TETA was infused into their coronary arteries. To further study the nature of defective cardiac Cu regulation in diabetes, we employed an isolated-perfused, working-heart model in which we infused micromolar doses of Cu²⁺ into the coronary arteries and measured acute effects on cardiac function in diabetic and non-diabetic-control rats. Infusion of CuCl₂ solutions caused acute dose-dependent cardiac dysfunction in normal hearts. Several measures of baseline cardiac function were impaired in diabetic hearts, and these defects were exacerbated by low-micromolar Cu²⁺ infusion. The response to infused Cu²⁺ was augmented in diabetic hearts, which became defective at lower infusion levels and underwent complete pump failure (cardiac output = 0 ml/min) more often (P < 0.0001) at concentrations that only moderately impaired function of control hearts. To our knowledge, this is the first report describing the acute effects on cardiac function of pathophysiological elevations in coronary Cu²⁺. The effects of Cu²⁺ infusion occur within minutes in both control and diabetic hearts, which suggests that they are not due to remodelling. Heightened sensitivity to the acute effects of small elevations in Cu²⁺ could contribute substantively to impaired cardiac function in patients with diabetes and is thus identified as a new mechanism of heart disease. Copyright © 2015 Elsevier Inc. All rights reserved.
Lee, Hyunjung; McKeon, Robert J; Bellamkonda, Ravi V
2010-02-23
Chondroitin sulfate proteoglycans (CSPGs) are a major class of axon growth inhibitors that are up-regulated after spinal cord injury (SCI) and contribute to regenerative failure. Chondroitinase ABC (chABC) digests glycosaminoglycan chains on CSPGs and can thereby overcome CSPG-mediated inhibition. But chABC loses its enzymatic activity rapidly at 37 degrees C, necessitating the use of repeated injections or local infusions for a period of days to weeks. These infusion systems are invasive, infection-prone, and clinically problematic. To overcome this limitation, we have thermostabilized chABC and developed a system for its sustained local delivery in vivo, obviating the need for chronically implanted catheters and pumps. Thermostabilized chABC remained active at 37 degrees C in vitro for up to 4 weeks. CSPG levels remained low in vivo up to 6 weeks post-SCI when thermostabilized chABC was delivered by a hydrogel-microtube scaffold system. Axonal growth and functional recovery following the sustained local release of thermostabilized chABC versus a single treatment of unstabilized chABC demonstrated significant differences in CSPG digestion. Animals treated with thermostabilized chABC in combination with sustained neurotrophin-3 delivery showed significant improvement in locomotor function and enhanced growth of cholera toxin B subunit-positive sensory axons and sprouting of serotonergic fibers. Therefore, improving chABC thermostability facilitates minimally invasive, sustained, local delivery of chABC that is potentially effective in overcoming CSPG-mediated regenerative failure. Combination therapy with thermostabilized chABC with neurotrophic factors enhances axonal regrowth, sprouting, and functional recovery after SCI.
Insulin pump-associated adverse events in children and adolescents--a prospective study.
Wheeler, Benjamin J; Heels, Kristine; Donaghue, Kim C; Reith, David M; Ambler, Geoffrey R
2014-09-01
Intensive insulin regimens are now the mainstay of modern, type 1 diabetes mellitus management. Insulin pumps (CSII) are a key technique used. Although there has been considerable study of outcomes, there are few recent data on CSII-associated adverse events (AEs) and their incidence and characteristics. Phone calls to our 24-h diabetes support service were screened for CSII-associated AEs. Phone interviews were conducted with the parent/patient, within 96 h of the event. Interviews explored AE characteristics and the role of the user, as well as questions relating to outcome and the impact to the family and patient. Comparisons were made with clinic CSII patients not reporting an AE. Over a 16-week study period, 50 confirmed AEs occurred in 45 of 405 (11.1%) patients. This was annualized to an AE incidence of 40 AEs/100 person-years. Pump malfunction and infusion set/site failures were the most common events reported, occurring in 27 (54.0%) and 18 (36.0%) AEs, respectively. A user- or education-related issue was implicated in 22 (44.0%) events. Pump replacement occurred in 19 of 50 occurrences (38.0%). Additionally, 16 (32.0%) reported a hospital admission or emergency department attendance as a consequence. When compared with those on CSII not reporting an AE, AEs were associated with age <10 years (odds ratio=3.2 [95% confidence interval, 1.7-6.1]) but not with gender, glycosylated hemoglobin, diabetes duration, or pumping duration. This is the first prospective study to look at AEs in modern-generation insulin pumps. AEs appear common and should be anticipated. Their origin is multifactorial, with the pump, associated consumables, and the user all being important factors. Ongoing support and anticipatory education are essential to minimize pump-associated AEs and their impact.
Anomalies in target-controlled infusion: an analysis after 20 years of clinical use.
Engbers, F H M; Dahan, A
2018-05-01
Although target-controlled infusion has been in use for more than two decades, its benefits are being obscured by anomalies in clinical practice caused by a number of important problems. These include: a variety of pharmacokinetic models available in open target-controlled infusion systems, which often confuse the user; the extrapolation of anthropomorphic data which provokes anomalous adjustments of dosing by such systems; and the uncertainty of regulatory requirements for the application of target-controlled infusion which causes uncontrolled exploitation of drugs and pharmacokinetic models in target-controlled infusion devices. Comparison of performance of pharmacokinetic models is complex and mostly inconclusive. However, a specific behaviour of a model in a target-controlled infusion system that is neither intended nor supported by scientific data can be considered an artefact or anomaly. Several of these anomalies can be identified in the current commercially available target-controlled infusion systems and are discussed in this review. © 2018 The Association of Anaesthetists of Great Britain and Ireland.
2003-08-01
Force of blades Extreme Moderate Moderate Moderate Temperature Heating, no A/C Heating, no A/C Heating, no A/C Heating, no A/C In-flight refueling Yes...CASEVAC CUBE CASEVAC PRICE 6515013215211 Airway Kit Percutaneous Emergency Adult Sterile Disposable 1.00 EA 0.2000 0.0500 $206.27 6515011676637...UI CASEVAC WEIGHT CASEVAC CUBE CASEVAC PRICE 6515014661488 Crystalloid and Colloid Pump Cartridges And IV Sets for the Power Infuser. Sterile
Continuous-Infusion Antipseudomonal Beta-Lactam Therapy in Patients With Cystic Fibrosis
Prescott, William A.; Gentile, Allison E.; Nagel, Jerod L.; Pettit, Rebecca S.
2011-01-01
Objective: We sought to evaluate the pharmacokinetics, efficacy, safety, stability, pharmacoeconomics, and quality-of-life effects of continuous-infusion antipseudomonal beta-lactam therapy in patients with cystic fibrosis (CF). Data Sources: Literature retrieval was accessed through Medline (from 1950 to December 2010) using the following terms: cystic fibrosis; beta-lactams or piperacillin or ticarcillin or cefepime or ceftazidime or doripenem or meropenem or imipenem/cilastin or aztreonam; continuous infusion or constant infusion; drug stability; economics, pharmaceutical; and quality of life. In addition, reference citations from identified publications were reviewed. Study Selection and Data Extraction: We evaluated all articles in English identified from the data sources. Data Synthesis: Patients with CF often harbor colonies of multidrug-resistant organisms, increasing the risk of suboptimal dosing and failure to meet the time above the minimum inhibitory concentration (T > MIC) pharmacodynamic targets. The pharmacokinetics of continuous-infusion antipseudomonal beta-lactam therapy in CF maintains serum concentrations above the MIC of susceptible strains and is more likely than intermittent infusion to achieve optimal T > MIC targets for some intermediate and resistant strains of Pseudomonas aeruginosa. Three noncomparative and four comparative studies have assessed the efficacy and safety of continuous-infusion antipseudomonal beta-lactam therapy during CF pulmonary exacerbations. Ceftazidime, the most extensively studied antibiotic for continuous infusion in CF, has been shown to improve forced expiratory volume in 1 second (FEV1), to improve forced vital capacity (FVC), and to extend the time between pulmonary exacerbations. Continuous-infusion cefepime has been studied in a small number of patients, and a trend toward improved pulmonary function has been observed. Continuous-infusion antipseudomonal beta-lactam therapy appears to be well tolerated, although most of the data pertain to ceftazidime. Because continuous infusion may necessitate that patients wear a portable pump in close proximity to the body, the stability of the antibiotic at body temperature must be considered. Several beta-lactams have good stability at body temperature (piperacillin/tazobactam, ticarcillin/clavulanate, and aztreonam) or acceptable if the medication cartridge is changed twice daily (cefepime and doripenem), whereas other beta-lactams have acceptable 24-hour stability only at lower temperatures (cefepime, ceftazidime, doripenem, and meropenem). Although no pharmacoeconomic studies have evaluated the cost–benefit of continuous infusion versus intermittent infusion in patients with CF, the potential medication cost reduction appears to be considerable. There is little information regarding the impact of continuous infusion on quality of life in patients with CF. Conclusion: Efficacy and safety studies suggest that ceftazidime, administered as a continuous infusion for the treatment of CF pulmonary exacerbations, is safe and effective; has the potential to reduce the costs of treatment; and is preferred to intermittent infusion among patients treated at home. Continuous-infusion ceftazidime may therefore be an alternative to traditional dosing on a case-by-case basis, such as for patients with multidrug-resistant isolates of P. aeruginosa. Treatment with continuous-infusion ceftazidime at home may be considered in such a case, assuming resources and support equivalent to the hospital setting can be ensured. Additional studies assessing the safety and efficacy of other antipseudomonal beta-lactams, when administered as a continuous infusion, during CF pulmonary exacerbations are needed. PMID:22346306
Infusing Systems Thinking into Career Counseling
ERIC Educational Resources Information Center
Ryan, Charles W.; Tomlin, James H.
2010-01-01
This study examined the role of career counselors in infusing systems thinking into occupational advising. The authors conducted a qualitative review and analysis of selected literature on systems thinking and analyzed trends for adaptation to career counseling practice. This analysis suggests that career counselors need to infuse systems…
Insulin Pump and CGM Usage in the United States and Germany
Walsh, John; Roberts, Ruth; Weber, Dietmar; Faber-Heinemann, Gabriele; Heinemann, Lutz
2015-01-01
Background: This survey collected and evaluated user responses about routine tasks and preferences regarding insulin pumps and infusion sets (IIS) with comparison of intercountry differences between the United States (US) and Germany (GER), chosen for their large insulin pump populations. Methods: A total of 985 subjects (534 US, 451 GER; 60% female) with type 1 diabetes on pump therapy anonymously answered 20 pump-related questions. US subjects also answered 11 questions about continuous glucose monitoring (CGM) usage. Results: Length of use of insulin cartridges is shorter in US than in GER, mean (SD) 4.3 (5.0) versus 5.3 (3.2) days (P < .001), while the IIS is used longer: 3.3 (1.0) versus 2.7 (1.1) days (P < .001). Lower self-reported HbA1c levels were associated with longer use of insulin cartridges (7.3% for >3 days vs 7.7% for <3 days; P < .01), and with use of an auto-insertion device (vs manual IIS insertion) in the US (7.2% vs 6.9%), but not in GER (7.7% vs 7.9%). Only 47% of pump wearers stated that they were “very satisfied” with their pump (49% US vs 45% GER, ns). However, 98% would recommend the pump to others (95% vs 93%, ns). Analysis of CGM questions showed that 297 (60%) of 496 US responders currently wore one. Of these, 84% said they would recommend CGM to others. CGM wearers who stated they were “very satisfied” with their CGM had lower HbA1c than those who said they were “partly satisfied” (6.9% vs 7.2%). Conclusions: This survey shows interesting differences in real-world use of insulin pumps in 2 large markets, and suggests areas where insulin pumps and CGMs might be improved. PMID:26071425
Effect of microbubble contrast on intracranial blood flow velocity assessed by transcranial Doppler.
Logallo, Nicola; Fromm, Annette; Waje-Andreassen, Ulrike; Thomassen, Lars; Matre, Knut
2014-03-01
Ultrasound contrast agents (UCA) salvage a considerable number of transcranial Doppler (TCD) exams which would have failed because of poor bone window. UCA bolus injection causes an undesirable increase in measured blood flow velocity (BFV). The effect of UCA continuous infusion on measured BFV has not been investigated, and some in vitro experiments suggest that gain reduction during UCA administration may also influence measured BFV. This study aimed to investigate the effect of UCA continuous infusion on BFV measured by TCD and the influence of gain reduction on these measurements in a clinical setting. The right middle cerebral artery of ten patients with optimal bone window was insonated using a 2 MHz probe. UCA were administered using an infusion pump. BFV was measured (1) at baseline, (2) during UCA infusion, (3) during UCA infusion with gain reduction, and (4) after UCA wash-out phase. Gain reduction was based on the agreement between two neurosonographers on the degree of gain reduction necessary to restore baseline Doppler signal intensity (DSI). Actual DSI was estimated offline by analysis of raw data. BFV measured during UCA infusion with no gain adjustment was significantly higher than baseline BFV [peak systolic velocity (PSV): 85.1 ± 19.7 vs. 74.4 ± 19.7 cm/s, p < 0.0001; Mean velocity (MV): 56.5 ± 11.8 vs. 50.2 ± 12.3 cm/s, p < 0.0001]. BFV measured during UCA infusion with gain reduction was not significantly higher than baseline BFV (PSV: 74.3 ± 18.9 vs. 74.4 ± 19.4 cm/s, p = 0.8; MV: 49.4 ± 11.0 vs. 50.2 ± 12.3 cm/s, p = 0.8). Actual DSI during UCA infusion with gain reduction was not significantly higher than baseline DSI (13 ± 1 vs. 13 ± 1 dB). This study shows that UCA continuous infusion leads to an increase in measured BFV which may be counteracted by reducing Doppler gain thus restoring pre-contrast DSI.
Leptin stimulates bone formation in ob/ob mice at doses having minimal impact on energy metabolism.
Philbrick, Kenneth A; Wong, Carmen P; Branscum, Adam J; Turner, Russell T; Iwaniec, Urszula T
2017-03-01
Leptin, the protein product of the ob gene, is essential for normal bone growth, maturation and turnover. Peripheral actions of leptin occur at lower serum levels of the hormone than central actions because entry of leptin into the central nervous system (CNS) is limited due to its saturable transport across the blood-brain barrier (BBB). We performed a study in mice to model the impact of leptin production associated with different levels of adiposity on bone formation and compared the response with well-established centrally mediated actions of the hormone on energy metabolism. Leptin was infused (0, 4, 12, 40, 140 or 400 ng/h) for 12 days into 6-week-old female ob/ob mice (n = 8/group) using sc-implanted osmotic pumps. Treatment resulted in a dose-associated increase in serum leptin. Bone formation parameters were increased at EC 50 infusion rates of 7-17 ng/h, whereas higher levels (EC 50 , 40-80 ng/h) were required to similarly influence indices of energy metabolism. We then analyzed gene expression in tibia and hypothalamus at dose rates of 0, 12 and 140 ng/h; the latter dose resulted in serum leptin levels similar to WT mice. Infusion with 12 ng/h leptin increased the expression of genes associated with Jak/Stat signaling and bone formation in tibia with minimal effect on Jak/Stat signaling and neurotransmitters in hypothalamus. The results suggest that leptin acts peripherally to couple bone acquisition to energy availability and that limited transport across the BBB insures that the growth-promoting actions of peripheral leptin are not curtailed by the hormone's CNS-mediated anorexigenic actions. © 2017 Society for Endocrinology.
Hasselmann, C; Pecquet, C; Bismuth, E; Raverdy, C; Sola-Gazagnes, A; Lobut, J-B; Carel, J-C; Tubiana-Rufi, N
2013-04-01
Insulin allergy is a rare but serious and challenging condition in patients with type 1 diabetes (T1D). This is a case report of an 8-year-old boy with T1D and an allergy to insulin. Three months after being diagnosed with T1D, the patient developed progressive skin reactions to insulin, characterized by small 1.5-cm pruritic wheals at injection sites that persisted for several days. Seven months after diagnosis, he experienced two episodes of generalized urticaria with systemic symptoms that were seen within a few seconds of insulin injection. Examination revealed lipoatrophy of the thighs. Intradermal skin tests were positive for protamine, glargine and lispro. The patient was started on a continuous subcutaneous insulin infusion (CSII) tolerance induction protocol, consisting of a very low basal rate that was progressively increased, with the first bolus given under medical supervision, and was well tolerated for 4 months. After this period of time, the skin wheals reappeared, localized to the infusion sites, but without urticaria or any other generalized reactions. Intradermal skin tests were repeated and were again positive. Serum insulin-specific IgE measured 30 months after the first allergic reactions were positive. After 3 years, pump therapy is ongoing and blood glucose control has remained relatively good (HbA1c 7.6%). In T1D children with insulin allergy, CSII can successfully be used to both induce insulin tolerance and allow diabetes insulin therapy, although insulin desensitization cannot always be fully achieved. The induction protocol was easily manageable partly due to the "honeymoon" period that the patient was still in, but it should nonetheless be used even when the patient has higher insulin requirements. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
[Cardiovascular effects of prostaglandin F 2 alpha in early pregnancy].
Retzke, U; Schwarz, R
1976-01-01
In 10 normotensive healthy early pregnant women cardiovascular studies were done before, during and after the intravenous administration of prostaglandin F2alpha with the method of quantitative sphygmometry. Arterial blood pressure was measured graphically with an automatic sphygmomanometer unit. Velocity of aortic pulse wave was determined directly on the principle of exact electronic timing. Prostaglandin F2alpha was infused with electric pump in the dosage of 6, 5, 13 and 26 mug per minute for 30 minutes in each case. Arterial blood pressure is nearly constant. Heart rate, the elasticity coefficient of the arteries E' and total peripheral resistance decreases significantly. Stroke volume, cardiac output, work and power of the heart increases significantly. Nevertheless there are no contra-indications on the part of cardiovascular system for using prostaglandin F2alpha for induction of abortion
Intravenous medication safety and smart infusion systems: lessons learned and future opportunities.
Keohane, Carol A; Hayes, Judy; Saniuk, Catherine; Rothschild, Jeffrey M; Bates, David W
2005-01-01
The Institute of Medicine report To Err Is Human: Building a Safe Health System greatly increased national awareness of the need to improve patient safety in general and medication safety in particular. Infusion-related errors are associated with the greatest risk of harm, and "smart" (computerized) infusion systems are currently available that can avert high-risk errors and provide previously unavailable data for continuous quality improvement (CQI) efforts. As healthcare organizations consider how to invest scarce dollars, infusion nurses have a key role to play in assessing need, evaluating technology, and selecting and implementing specific products. This article reviews the need to improve intravenous medication safety. It describes smart infusion systems and the results they have achieved. Finally, it details the lessons learned and the opportunities identified through the use of smart infusion technology at Brigham and Women's Hospital in Boston, Massachusetts.
A new infusion pathway intactness monitoring system.
Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton
2006-01-01
A new infusion pathway monitoring system has been developed for hospital and home use. The system consists of linear integrated circuits and a low-power 8-bit single chip microcomputer which constantly monitors the infusion pathway intactness. An AC (alternating current) voltage is induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The induced AC voltage can be recorded by a main electrode wrapped around the infusion polyvinyl chloride tube. A reference electrode is wrapped on the electrode to monitor the AC voltage around the main electrode. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltages and alerts the nursing station, via the nurse call system or PHS (personal handy phone system).
Katsuoka, Yuichi; Ohta, Hiroki; Fujimoto, Eisuke; Izuhara, Luna; Yokote, Shinya; Kurihara, Sho; Yamanaka, Shuichiro; Tajiri, Susumu; Chikaraish, Tatsuya; Okano, Hirotaka J; Yokoo, Takashi
2016-04-01
Mesenchymal stem cell therapy in renal failure is rarely used because of low rates of cell engraftment after systemic delivery. Repeated intra-arterial cell administration may improve results; however, no current delivery method permits repeated intra-arterial infusions in a rat model. In this study, we developed an intra-arterial delivery system for repeated stem cell infusion via the aorta, catheterizing the left femoral artery to the suprarenal aorta under fluoroscopic guidance in rats with adenosine-induced renal failure. First, we compared our intra-arterial catheter system (C group, n = 3) with tail vein injection (V group, n = 3) for engraftment efficacy, using mesenchymal stem cells from luciferase transgenic rats. Rats were infused with the cells and euthanized the following day; we performed cell-tracking experiments using a bioluminescence imaging system to assess the distribution of the infused cells. Second, we assessed the safety of the system over a 30-day period in a second group of six rats receiving infusions every 7 days. Cells infused through our delivery system efficiently engrafted into the kidney, compared with peripheral venous infusion. In five of the six rats in the safety study, the delivery system remained patent for at least 9 days (range, 9-24 days). Complications became evident only after 10 days. Our intra-arterial catheter system was effective in delivering cells to the kidney and permitted repeated injection of cells.
Evaluation of an investigational wearable injector in healthy human volunteers.
Torjman, Marc C; Machnicki, Robert; Lessin, Jennifer; Loeum, Channy; Steinberger, Douglas; Mycroft, Sarah; Joseph, Jeffrey I
2017-01-01
Introduction of a wearable device for subcutaneous delivery of larger volume bolus injections would encourage patient compliance and reduce the burden on healthcare services. With one such wearable device commercially available, this study examined the safety and functionality of an investigational device in volunteers. Four devices were applied to the subject's abdomen: 1) Investigational Device, 2) Investigational Device: subject movement, 3) Control Device: FDA-cleared syringe driver with FDA-cleared infusion set, 4) Control Device: FDA-cleared syringe driver attached to investigational device. Three milliliters of saline were infused through the four devices over 3 minutes. 84 devices were applied to 21 subjects. Three milliliters of saline were safely delivered subcutaneously from the investigational and control devices. Two control devices had occlusions and in each case the pump reached its high pressure limit of 12 psi. VAS pain measurements showed minimal pain for all subjects. Pain scores were significantly (p < 0.001) higher than baseline at the end of injection: mean pain level ranged from 2.0-22.0 mm. The investigational device performed as intended with minimal pain during needle insertion and infusion, and no leaking of fluid at the skin puncture site. Two occlusions occurred with the control devices.
Cifani, Carlo; Guerrini, Remo; Massi, Maurizio; Polidori, Carlo
2006-11-01
Central administration of low doses of nociceptin/orphanin FQ (N/OFQ), the endogenous ligand of the opioid-like orphan receptor NOP, have been shown to reduce ethanol consumption, ethanol-induced conditioned place preference and stress-induced reinstatement of alcohol-seeking behavior in alcohol preferring rats. The present study evaluated the effect of continuous (7 days) lateral brain ventricle infusions of N/OFQ (0, 0.25, 1, 4, and 8 microg/h), by means of osmotic mini-pumps, on 10% ethanol intake in Marchigian-Sardinian alcohol-preferring (msP) rats provided 2h or 24h access to it. N/OFQ dose-dependently increased food intake in msP rats. On the other hand, in contrast to previous studies with acute injections, continuous lateral brain ventricle infusion of high doses of N/OFQ increased ethanol consumption when the ethanol solution was available for 24h/day or 2h/day. The present study demonstrates that continuous activation of the opioidergic N/OFQ receptor does not blunt the reinforcing effects of ethanol. Moreover, the data suggest that continuous activation of the opioidergic N/OFQ receptor is not a suitable way to reduce alcohol abuse.
Pharmacologic Atrial Natriuretic Peptide Reduces Human Leg Capillary Filtration
NASA Technical Reports Server (NTRS)
Watenpaugh, Donald E.; Vissing, Susanne F.; Lane, Lynda D.; Buckey, Jay C.; Firth, Brian G.; Erdman, William; Hargens, Alan R.; Blomqvist, C. Gunnar
1995-01-01
Atrial natriuretic peptide (ANP) is produced and secreted by atrial cells. We measured calf capillary filtration rate with prolonged venous-occlusion plethys-mography of supine health male subjects during pharmacologic infusion of ANP (48 pmol/kg/min for 15 min; n equals 6) and during placebo infusion (n equals 7). Results during infusions were compared to prior control measurements. ANP infusion increased plasma (ANP) from 30 plus or minus 4 to 2,568 plus or minus 595 pmol/L. Systemic hemoconcentration occurred during ANP infusion; mean hematocrit and plasma colloid osmotic pressure increased 4.6 and 11.3 percent respectively, relative to pre-infusion baseline values (p is less than 0.05). Mean calf filtration, however was significantly reduced from 0.15 to 0.08 ml/100 ml/min with ANP. Heart rate increased 20 percent with ANP infusion, wheras blood pressure was unchanged. Calf conductance (blood flow/arterial pressure) and venous compliance were unaffected by ANP infusion. Placebo infusion had no effect relative to prior baseline control measurements. Although ANP induced systemic capillary filtration, in the calf, filtration was reduced with ANP. Therefore, phamacologic ANP infusion enhances capillary filtration from the systemic circulation, perhaps at upper body or splanchic sites or both, while having the opposite effect in the leg.
Pharmacologic Atrial Natriuretic Peptide Reduces Human Leg Capillary Filtration
NASA Technical Reports Server (NTRS)
Watenpaugh, Donald E.; Vissing, Susanne F.; Lane, Lynda D.; Buckey, Jay C.; Firth, Brian G.; Erdman, William; Hargens, Alan R.; Blomqvist, C. Gunnar
1995-01-01
Atrial natriuretic peptide (ANP) is produced and secreted by atrial cells. We measured calf capillary filtration rate with prolonged venous-occlusion plethysmography of supine healthy male subjects during pharmacologic infusion of ANP (48 pmol/kg/min for 15 min; n = 6) and during placebo infusion (n = 7). Results during infusions were compared to prior control measurements. ANP infusion increased plasma (ANP) from 30 +/- 4 to 2,568 +/- 595 pmol/L. Systemic hemoconcentration occurred during ANP infusion: mean hematocrit and plasma colloid osmotic pressure increased 4.6 and 11.3%, respectively, relative to preinfusion baseline values (p less than 0.05). Mean calf filtration, however, was significantly reduced from 0.15 to 0.08 ml/100 ml/min with ANP. Heart rate increased 20% with ANP infusion, whereas blood pressure was unchanged. Calf conductance (blood flow/ arterial pressure) and venous compliance were unaffected by ANP infusion. Placebo infusion had no effect relative to prior baseline control measurements. Although ANP induced systemic capillary filtration, in the calf, filtration was reduced with ANP. Therefore, pharmacologic ANP infusion enhances capillary filtration from the systemic circulation, perhaps at upper body or splanchnic sites or both, while having the opposite effect in the leg.
Weiss, J M; Simson, P G; Hoffman, L J; Ambrose, M J; Cooper, S; Webster, A
1986-04-01
These studies examined how pharmacological stimulation and blockade of alpha receptors would affect active motor behavior in rats. In experiment I, alpha-2 receptor antagonists (piperoxane, yohimbine) and agonists [clonidine, norepinephrine (NE)] were infused into various locations in the ventricular system of the brain, including the locus coeruleus region, and motor activity was measured. Activity was measured principally in a swim test but spontaneous (ambulatory) activity was also recorded while drugs were being infused. When infused into the locus coeruleus region, small doses of the antagonists piperoxane and yohimbine depressed activity in the swim test while infusion of the agonists clonidine and NE had the opposite effect of stimulating activity. These effects were highly specific to the region of the locus coeruleus, since infusions of these drugs into other nearby locations in the ventricular system or use of larger doses had different, often opposite effects. This was especially true of clonidine and NE which profoundly depressed activity when infused posterior to the locus coeruleus, particularly over the dorsal vagal complex. Infusion of small doses of these drugs into the lateral ventricle had effects similar to infusion into the locus coeruleus region, though less pronounced. Changes in spontaneous motor activity were also observed, but this measure differentiated the groups less well than did the swim test. In experiment II, the predominantly postsynaptic receptor agonists isoproterenol (beta agonist) and phenylephrine (alpha-1 agonist) were infused into the ventricular system. Since infusions of piperoxane and yohimbine into the locus coeruleus that decreased activity in experiment I increase the release of NE by blocking alpha-2 inhibitory receptors on cell bodies and dendrites of the locus coeruleus, experiment II tested whether ventricular infusion of predominantly postsynaptic receptor agonists would also decrease activity in the swim test. Both isoproterenol and phenylephrine produced this effect, but did so selectively with respect to dose and location of infusion in the ventricular system. These findings are consistent with recent results relating to the mechanism that underlies stress-induced depression of active behavior.
Annual Historical Report, AMEDD Activities, Calendar Year 1989
1989-01-01
Durkot, J.L. Briggs, M.S. Rose and E.W. Askew. Metabolic effects of supplementing a hypocaloric diet with fat. FASEB J. 3:A448, 1989. 26. Sutton...a hypocaloric diet with fat. FASEB J. 3(3):A448, 1989. 22. Morgan, T.E., S.H. Laramee. Enteral alimentation: Pump- controlled nutrient infusion. J...calorie deficient diet for 30 days. FASEB J. 3:A463, 1989. 24. Meehan, R.T., N.M. Cintron, W.J. Kraemer, P.B. Rock and A. Cymerman. Association between
Lee, Hyung-Chul; Ryu, Ho-Geol; Chung, Eun-Jin; Jung, Chul-Woo
2018-03-01
The discrepancy between predicted effect-site concentration and measured bispectral index is problematic during intravenous anesthesia with target-controlled infusion of propofol and remifentanil. We hypothesized that bispectral index during total intravenous anesthesia would be more accurately predicted by a deep learning approach. Long short-term memory and the feed-forward neural network were sequenced to simulate the pharmacokinetic and pharmacodynamic parts of an empirical model, respectively, to predict intraoperative bispectral index during combined use of propofol and remifentanil. Inputs of long short-term memory were infusion histories of propofol and remifentanil, which were retrieved from target-controlled infusion pumps for 1,800 s at 10-s intervals. Inputs of the feed-forward network were the outputs of long short-term memory and demographic data such as age, sex, weight, and height. The final output of the feed-forward network was the bispectral index. The performance of bispectral index prediction was compared between the deep learning model and previously reported response surface model. The model hyperparameters comprised 8 memory cells in the long short-term memory layer and 16 nodes in the hidden layer of the feed-forward network. The model training and testing were performed with separate data sets of 131 and 100 cases. The concordance correlation coefficient (95% CI) were 0.561 (0.560 to 0.562) in the deep learning model, which was significantly larger than that in the response surface model (0.265 [0.263 to 0.266], P < 0.001). The deep learning model-predicted bispectral index during target-controlled infusion of propofol and remifentanil more accurately compared to the traditional model. The deep learning approach in anesthetic pharmacology seems promising because of its excellent performance and extensibility.
Ultra-low dose (+)-naloxone restores the thermal threshold of morphine tolerant rats.
Chou, Kuang-Yi; Tsai, Ru-Yin; Tsai, Wei-Yuan; Wu, Ching-Tang; Yeh, Chun-Chang; Cherng, Chen-Hwan; Wong, Chih-Shung
2013-12-01
As known, long-term morphine infusion leads to tolerance. We previously demonstrated that both co-infusion and post-administration of ultra-low dose (±)-naloxone restores the antinociceptive effect of morphine in morphine-tolerant rats. However, whether the mechanism of the action of ultra-low dose (±)-naloxone is through opioid receptors or not. Therefore, in the present study, we further investigated the effect of ultra-low dose (+)-naloxone, it does not bind to opioid receptors, on the antinociceptive effect of morphine. Male Wistar rats were implanted with one or two intrathecal (i.t.) catheters; one catheter was connected to a mini-osmotic pump, used for morphine (15 μg/h), ultra-low dose (+)-naloxone (15 pg/h), morphine plus ultra-low dose (+)-naloxone (15 pg/h) or saline (1 μl/h) infusion for 5 days. On day 5, either ultra-low dose (+)-naloxone (15 pg) or saline (5 μl) was injected via the other catheter immediately after discontinued morphine or saline infusion. Three hours later, morphine (15 μg in 5 μl saline) or saline were given intrathecally. All rats received nociceptive tail-flick test every 30 minutes for 120 minutes after morphine challenge at different temperature (45-52°C, respective). Our results showed that, both co-infusion and post-treatment of ultra-low dose (+)-naloxone with morphine preserves the antinociceptive effect of morphine. Moreover, in the post administration rats, ultra-low dose (+)-naloxone further enhances the antinociceptive effect of morphine. This study provides an evidence for ultra-low dose (+)-naloxone as a therapeutic adjuvant for patients who need long-term opioid administration for pain management. Copyright © 2013. Published by Elsevier B.V.
Gomez Sanchez, E P
1988-06-01
We have shown previously that the intracerebroventricular (icvt) infusion of 5 ng/h aldosterone (ALD) in the sensitized rat (one kidney removed, 1% NaCl plus 0.15% KCl solution to drink) produced hypertension similar in amplitude and time of onset to a 100-fold dose administered subcutaneously (s.c.), while a 5-ng/h subcutaneous infusion had no effect on blood pressure (BP). Dose-response studies on the icvt infusion of ALD were carried out in sensitized and non-sensitized (intact, with tap water to drink) male Sprague-Dawley rats (SDR). In both studies, a control group received the diluent, artificial cerebrospinal fluid (CSF), icvt. In sensitized rats, the pressures became significantly (P less than 0.05) elevated at day 7 in those receiving 15 ng/h icvt, day 11 in those receiving 5 ng/h icvt and 500 ng/h s.c. and day 18 in those receiving 1.5 ng/h icvt. The indirect systolic BPs at day 20 of infusion were 119 +/- 0.8 (s.e.) mmHg for controls, 182 +/- 5 for 15 ng/h icvt, 140 +/- 2 mmHg for 5 ng/h icvt, 131 +/- 1 mmHg for 1.5 ng/h icvt, 125 +/- 1 mmHg for 0.5 ng/h, and 159 +/- 5 mmHg for 500 ng/h s.c. Recovery (removal of pumps and return to water to drink) for 18 days resulted in the return of normal pressures in all groups except the 15 ng/h, icvt group in which pressures remained slightly, but significantly elevated at 127 +/- 3 mmHg. In non-sensitized rats, the pressures became significantly elevated in animals receiving 45 ng/h icvt and 1 microgram/h s.c. by day 14.(ABSTRACT TRUNCATED AT 250 WORDS)
On the efficiency of small air coil motors
NASA Astrophysics Data System (ADS)
Horowitz, P.
1981-05-01
The efficiency of two types of small ironless motors in the output range of 5 to 500 mW was investigated for use in driving a miniature roller pump for a portable infusion system. One motor has a continuous rotating coil (commutator motor) and one has an oscillating coil. In this case a ratchet and ratchet wheel is needed to generate a rotating motion (ratchet wheel motor). The electromechanical transducer and a mechanical transformation and support system are discussed as well as frictional losses. The influence of the size of the motor is discussed. An expression for the total efficiency is obtained which enables the calculation of the speed of rotation of a certain motor at maximum efficiency for a certain required output. This optimal speed of rotation is hardly influenced by the required speed of rotation at the output shaft of the driving. The transmission, if required, has only a small effect on the optimum speed of rotation of the motor.
Health Informatics for Neonatal Intensive Care Units: An Analytical Modeling Perspective
Mench-Bressan, Nadja; McGregor, Carolyn; Pugh, James Edward
2015-01-01
The effective use of data within intensive care units (ICUs) has great potential to create new cloud-based health analytics solutions for disease prevention or earlier condition onset detection. The Artemis project aims to achieve the above goals in the area of neonatal ICUs (NICU). In this paper, we proposed an analytical model for the Artemis cloud project which will be deployed at McMaster Children’s Hospital in Hamilton. We collect not only physiological data but also the infusion pumps data that are attached to NICU beds. Using the proposed analytical model, we predict the amount of storage, memory, and computation power required for the system. Capacity planning and tradeoff analysis would be more accurate and systematic by applying the proposed analytical model in this paper. Numerical results are obtained using real inputs acquired from McMaster Children’s Hospital and a pilot deployment of the system at The Hospital for Sick Children (SickKids) in Toronto. PMID:27170907
NASA Technical Reports Server (NTRS)
1974-01-01
Performance testing carried out in the development of the prototype zero-g fluid infusion system is described and summarized. Engineering tests were performed in the course of development, both on the original breadboard device and on the prototype system. This testing was aimed at establishing baseline system performance parameters and facilitating improvements. Acceptance testing was then performed on the prototype system to verify functional performance. Acceptance testing included a demonstration of the fluid infusion system on a laboratory animal.
Depressive Symptoms, Emotion Dysregulation, and Bulimic Symptoms in Youth With Type 1 Diabetes
Young-Hyman, Deborah L.; Peterson, Claire M.; Fischer, Sarah; Markowitz, Jessica T.; Muir, Andrew B.; Laffel, Lori M.
2016-01-01
This study evaluated the associations between depressive symptoms, emotion dysregulation and bulimic symptoms in youth with type 1 diabetes (T1D) in the context of the diagnosis and treatment of T1D. Study participants were 103 youth in 2 distinct groups: newly diagnosed (New) or transitioning to pump therapy (continuous subcutaneous insulin infusion [CSII]; “Pump”), who completed questionnaires regarding symptoms of depression, emotion dysregulation, and bulimia. Glycemic control (A1c), height, weight, and questionnaires were evaluated within 10 days of diagnosis (n = 58) or at education/clinic visit before starting insulin utilizing CSII (n = 45). In the newly diagnosed group, only depression accounted for significant variance in bulimia scores (β = .47, P < .01). For the group with disease treatment experience (Pump), but not for the newly diagnosed group (New), greater depressive symptoms and emotion dysregulation were associated with greater bulimic symptoms. Depressive symptoms and emotion dysregulation, an indicator of poor coping/behavioral control, could help explain adoption of disordered eating behaviors in youth with T1D who are transitioning to pump therapy. PMID:27137457
Morris, D J; Gorsline, J; Tresco, P A; Harnik, M
1985-12-01
The relative hypertensinogenic potencies of recently synthesized 19-nor-aldosterone and its precursor 19-OH-aldosterone were assessed in comparison to that of aldosterone (Aldo) in young (6-week-old) adrenalectomized (ADX) spontaneously hypertensive rats (SHR). Infusion of 19-nor-aldosterone for 2 weeks by Alza mini-osmotic pumps caused significant, dose-dependent increases in the systolic blood pressure (BP) of young ADX SHR; dosages of 0.1 and 0.5 microgram/day raised the BP from 127 +/- 2 mmHg to 164 +/- 9 and 180 +/- 11 mmHg, respectively. During this period, control ADX SHR receiving vehicle only remained normotensive. Similar increases in BP were seen only with infusion of slightly higher dosages of Aldo (0.5 and 1.0 micrograms/day). In contrast, 19-OH-aldosterone infused at higher dosages (10 or 25 micrograms/day) caused little change in BP of ADX SHR. Full suppression of plasma renin activity (PRA) was observed with 0.1 and 0.5 microgram/day 19-nor-aldosterone, whereas Aldo caused similar decreases in PRA only at dosages of 0.5 microgram/day and higher. Interestingly, although infusions of 19-OH-aldosterone did not cause a significant change in BP, these dosages (10 and 25 micrograms/day) significantly suppressed PRA. These studies which show that 19-nor-aldosterone is equipotent to Aldo, and perhaps slightly more active in ADX SHR, indicate that 19-nor-aldosterone is a potentially important hypertensinogenic steroid.
Duara, Rajnish; Misra, Manoranjan; Bhuyan, Ritwick Raj; Sarma, P. Sankara; Jayakumar, Karunakaran
2008-01-01
Objective: Homologous blood transfusion after open heart surgery puts a tremendous load on the blood banks. This prospective randomized study evaluates the efficacy of infusing back residual cardiopulmonary bypass (CPB) circuit i.e., pump blood as a means to reduce homologous transfusion after coronary artery bypass surgery (CABG) and whether its use increases postoperative drainage. Materials and Methods: Sixty-seven consecutive patients who underwent elective CABGs under CPB were randomized into 2 groups: (1) cases where residual pump blood was used and (2) controls where residual pump blood was not used. Patients were monitored for hourly drainage on the day of surgery and the 1st postoperative day and the requirements of homologous blood and its products. Data were matched regarding change in Hemoglobin, Packed Cell Volume and coagulation parameters till 1st postoperative day. All cases were followed up for three years. Results: There was a marginal reduction in bleeding pattern in the early postoperative period in the cases compared to controls. The requirement of homologous blood and its products were also reduced in the cases. Conclusions: The use of CPB circuit blood is safe in the immediate postoperative period. The requirement of homologous blood transfusion can come down if strict transfusion criteria are maintained. PMID:20041077
Mader, Timothy J; Walterscheid, Joshua K; Kellogg, Adam R; Lodding, Cynthia C
2010-01-01
This study was done, using a swine model of prolonged ventricular fibrillation out-of-hospital cardiac arrest, to determine the feasibility of inducing therapeutic hypothermia after successful resuscitation by giving an intraosseous infusion of iced saline. This study was IACUC approved. Liter bags of normal saline, after being refrigerated for at least 24h, were placed in an ice filled cooler. Female Yorkshire swine weighing between 27 and 35 kg were sedated and instrumented under general anesthesia. A temperature probe was inserted 10 cm into the esophagus. Ventricular fibrillation was electrically induced and allowed to continue untreated for 10 min. Animals were randomized to one of two resuscitation schemes for the primary study (N=53). One group had central intravenous access for drug delivery and the other had an intraosseous needle inserted into the proximal tibia for drug administration. Animals in which spontaneous circulation was restored were immediately cooled, for this secondary study, by means of a rapid, pump-assisted infusion of 1L of iced saline either through the intraosseous needle (n=8), the central access (n=6), or a peripheral intravenous catheter (n=7) in a systematic, non-randomized fashion. Room, animal, and saline temperatures were recorded at initiation and upon completion of infusion. The data were analyzed descriptively using Stata SE v8.1 for Macintosh. The baseline characteristics of all three groups were mathematically the same. The average ambient room temperature during the experimental sessions was 25.5 degrees C (SD=1.3 degrees C). There were no statistically significant differences between the three groups with regard to saline temperature, rate of infusion, or decrease in core body temperature. The decrease in core temperature for the intraosseous group was 2.8 degrees C (95% CI=1.8, 3.8) over the infusion period. Mild therapeutic hypothermia can be effectively induced in swine after successful resuscitation of prolonged ventricular fibrillation by infusion of iced saline through an IO needle. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
Torres, Susana; Brown, Roland; Zelesky, Todd; Scrivens, Garry; Szucs, Roman; Hawkins, Joel M; Taylor, Mark R
2016-11-30
Stability studies of pharmaceutical drug products and pharmaceutical active substances are important to research and development in order to fully understand and maintain product quality and safety throughout its shelf-life. Oxidative forced degradation studies are among the different types of stability studies performed by the pharmaceutical industry in order to understand the intrinsic stability of drug molecules. We have been comparing the use of electrochemistry as an alternative oxidative forced degradation method to traditional forced degradation and accelerated stability studies. Using the electrochemical degradation approach the substrate oxidation takes place in a commercially available electrochemical cell and the effluent of the cell can be either a) directly infused into the mass spectrometer or b) injected in a chromatographic column for separation of the different products formed prior to the mass spectrometry analysis. To enable the study of large numbers of different experimental conditions and molecules we developed a new dual pump automated electrochemical screening platform. This system used a HPLC pump and autosampler to load and wash the electrochemical cell and deliver the oxidized sample plug to a second injection loop. This system enabled the automatic sequential analyses of large numbers of different solutions under varied experimental conditions without need for operator intervention during the run sequence. Here we describe the system and evaluate its performance using a test molecule with well characterized stability and compare results to those obtained using an off-line electrochemistry approach. Copyright © 2016 Elsevier B.V. All rights reserved.
Górka, P; Śliwiński, B; Flaga, J; Wieczorek, J; Godlewski, M M; Wierzchoś, E; Zabielski, R; Kowalski, Z M
2017-05-01
The aim of the study was to determine the effect of butyrate infusion into the rumen on butyrate flow to the duodenum, expression of short-chain fatty acid (SCFA) transporters (monocarboxylate transporter-1, -2, and -4) and receptors (G protein coupled receptor-41 and -43) in the duodenal epithelium and nutrient digestion in sheep. Eight wethers (39.0 ± 3.00 kg; mean ± SD) with ruminal and T-shape duodenal cannulas were allocated to 4 × 4 replicated Latin square design with each experimental period lasting for 21 d (12 d of adaptation and 9 d for data and sample collection). Experimental treatments were: 1) distilled water infusion into the rumen (CONT); 2) 15 g/d of butyric acid infusion into the rumen (BUT15); 3) 30 g/d of butyric acid infusion into the rumen (BUT30); and 4) 45 g/d of butyric acid infusion into the rumen (BUT45). The daily dose of butyrate was infused into the rumen via the rumen cannula, with 200 mL of solution of butyric acid and distilled water, at a constant rate (0.1389 mL/min) throughout the day using a peristaltic pump. Correspondingly, 200 mL/d of distilled water was infused into the rumen of CONT. The wethers were fed daily 900 g of chopped meadow hay and 200 g of concentrate in two equal meals at 0600 and 1800 h. Butyrate infusion into the rumen did not affect total SCFA concentration in the rumen fluid ( > 0.11). Molar proportion of butyrate in total SCFA linearly increased, and molar proportion of acetate and isovalerate linearly decreased ( ≤ 0.02) with an increasing amount of butyrate infused into the rumen. The molar proportion of butyrate in total SCFA in the duodenal digesta linearly increased ( < 0.01), and butyrate flow to duodenum tended to linearly increase ( = 0.06) with an increasing dose of exogenous butyrate delivered to the rumen. Butyrate infusion into the rumen did not affect ( ≥ 0.14) the mRNA expression of monocarboxylate transporter-2 and -4 and G protein coupled receptor-43 in the duodenal epithelium. The G protein coupled receptor-41 and monocarboxylate transporter-1 mRNA expression in the duodenal epithelium was very low in many of the analyzed samples. Digestibility of organic matter, neutral detergent fiber, and acid detergent fiber in the stomach (forestomach and abomasum) decreased for BUT15 and BUT30 and then increased for BUT45 (quadratic, ≤ 0.04); however, neither digestibility in the intestine nor total tract digestibility differed between treatments ( ≥ 0.10).
Cerebrospinal fluid volume measurements in hydrocephalic rats.
Basati, Sukhraaj; Desai, Bhargav; Alaraj, Ali; Charbel, Fady; Linninger, Andreas
2012-10-01
Object Experimental data about the evolution of intracranial volume and pressure in cases of hydrocephalus are limited due to the lack of available monitoring techniques. In this study, the authors validate intracranial CSF volume measurements within the lateral ventricle, while simultaneously using impedance sensors and pressure transducers in hydrocephalic animals. Methods A volume sensor was fabricated and connected to a catheter that was used as a shunt to withdraw CSF. In vitro bench-top calibration experiments were created to provide data for the animal experiments and to validate the sensors. To validate the measurement technique in a physiological system, hydrocephalus was induced in weanling rats by kaolin injection into the cisterna magna. At 28 days after induction, the sensor was implanted into the lateral ventricles. After sealing the skull using dental cement, an acute CSF drainage/infusion protocol consisting of 4 sequential phases was performed with a pump. Implant location was confirmed via radiography using intraventricular iohexol contrast administration. Results Controlled CSF shunting in vivo with hydrocephalic rats resulted in precise and accurate sensor measurements (r = 0.98). Shunting resulted in a 17.3% maximum measurement error between measured volume and actual volume as assessed by a Bland-Altman plot. A secondary outcome confirmed that both ventricular volume and intracranial pressure decreased during CSF shunting and increased during infusion. Ventricular enlargement consistent with successful hydrocephalus induction was confirmed using imaging, as well as postmortem. These results indicate that volume monitoring is feasible for clinical cases of hydrocephalus. Conclusions This work marks a departure from traditional shunting systems currently used to treat hydrocephalus. The overall clinical application is to provide alternative monitoring and treatment options for patients. Future work includes development and testing of a chronic (long-term) volume monitoring system.
Lee, Hyung-Chul; Jung, Chul-Woo
2018-01-24
The current anaesthesia information management system (AIMS) has limited capability for the acquisition of high-quality vital signs data. We have developed a Vital Recorder program to overcome the disadvantages of AIMS and to support research. Physiological data of surgical patients were collected from 10 operating rooms using the Vital Recorder. The basic equipment used were a patient monitor, the anaesthesia machine, and the bispectral index (BIS) monitor. Infusion pumps, cardiac output monitors, regional oximeter, and rapid infusion device were added as required. The automatic recording option was used exclusively and the status of recording was frequently checked through web monitoring. Automatic recording was successful in 98.5% (4,272/4,335) cases during eight months of operation. The total recorded time was 13,489 h (3.2 ± 1.9 h/case). The Vital Recorder's automatic recording and remote monitoring capabilities enabled us to record physiological big data with minimal effort. The Vital Recorder also provided time-synchronised data captured from a variety of devices to facilitate an integrated analysis of vital signs data. The free distribution of the Vital Recorder is expected to improve data access for researchers attempting physiological data studies and to eliminate inequalities in research opportunities due to differences in data collection capabilities.
[Clinical study of recurrent stomach cancer].
Taguchi, T
1983-11-01
There are various patterns of recurrence of gastric cancer after radical resection, such as hepatic metastasis, carcinomatous peritonitis, residual stomach recurrence, local lymph node metastasis and establishment of distant metastasis. In cases of residual stomach recurrence, resection is sometimes feasible. Kruckenberg's tumor resulting from metastasis to the ovary can frequently be removed. With such resectable metastasis, surgical procedure is actively employed, with subsequent chemotherapy. Chemotherapy in such a case consists of combined chemotherapy by arterial infusion for induction of remission and administration of oral preparation and/or suppositories for maintenance. In the treatment of recurrent gastric cancer by arterial infusion, we made it a rule to administer drugs through a catheter inserted subselectively into the aorta. In the treatment by arterial infusion, the daily administration of 5-FU serves as the basic regimen. Dissolve 250 mg 5-FU in about 20 cc physiologic saline or 5% dextrose solution, and infuse the solution over 2 hrs with the use of a continuous arterial infusion pump. Administer of 5-FU daily, and fortify this treatment by one-shot injection of MMC 10mg/body each time, MMC is usually given 3-4 times, with intervals between its administrations adjusted according to WBC and platelet counts. ADM is given at dosage of 40 mg/body each time. We found it advisable to continue the administrations of 5-FU until its total dose reached about 20 g, while giving sufficient doses of ADM or MMC for induction of remission. The results obtained from 108 cases of the recurrent gastric cancer were shown as follows. The median survival period was 5 months. The twenty-one cases out of 108 cases in recurrent gastric cancer survived more than one year, because they received the intensive chemotherapy such as arterial infusion chemotherapy and oral or rectal administration of FT. The most patients with liver metastasis were treated with selective arterial infusion chemotherapy consisting of 5-FU plus MMC or ACNU. And the efficacy of arterial infusion chemotherapy was remarkable. Our efforts must be made to continue any treatment as long as possible and change drugs as necessary. Also we must keep general condition of the patients as good as possible using support therapy such as IVH, prevention of infection, immunotherapy, drainage so on.
APA national audit of pediatric opioid infusions.
Morton, Neil S; Errera, Agata
2010-02-01
A prospective audit of neonates, infants, and children receiving opioid infusion techniques managed by pediatric acute pain teams from across the United Kingdom and Eire was undertaken over a period of 17 months. The aim was to determine the incidence, nature, and severity of serious clinical incidents (SCIs) associated with the techniques of continuous opioid infusion, patient-controlled analgesia, and nurse-controlled analgesia in patients aged 0-18. The audit was funded by the Association of Paediatric Anaesthetists (APA) and performed by the acute pain services of 18 centers throughout the United Kingdom. Data were submitted weekly via a web-based return form designed by the Document Capture Company that documented data on all patients receiving opioid infusions and any SCIs. Eight categories of SCI were identified in advance, and the reported SCIs were graded in terms of severity (Grade 1 (death/permanent harm); Grade 2 (harm but full recovery and resulting in termination of the technique or needing significant intervention); Grade 3 (potential but no actual harm). Data were collected over a period of 17 months (25/06/07-25/11/08) and stored on a secure server for analysis. Forty-six SCIs were reported in 10 726 opioid infusion techniques. One Grade 1 incident (1 : 10,726) of cardiac arrest occurred and was associated with aspiration pneumonitis and the underlying neurological condition, neurocutaneous melanosis. Twenty-eight Grade 2 incidents (1 : 383) were reported of which half were respiratory depression. The seventeen Grade 3 incidents (1 : 631) were all drug errors because of programming or prescribing errors and were all reported by one center. The overall incidence of 1 : 10,000 of serious harm with opioid infusion techniques in children is comparable to the risks with pediatric epidural infusions and central blocks identified by two recent UK national audits (1,2). Avoidable factors were identified including prescription and pump programming errors, use of concurrent sedatives or opioids by different routes and overgenerous dosing in infants. Early respiratory depression in patients with specific risk factors, such as young age, neurodevelopmental, respiratory, or cardiac comorbidities, who are receiving nurse-controlled analgesia or continuous opioid infusion suggests that closer monitoring for at least 2 h is needed for these cases. As a result of this audit, we can provide parents with better information on relative risks to help the process of informed consent.
Solovyova, Olga; Lewis, Courtland G; Abrams, Jonathan H; Grady-Benson, John; Joyce, Michael E; Schutzer, Steven F; Arumugam, Sivasenthil; Caminiti, Stephanie; Sinha, Sanjay K
2013-11-06
We studied the efficacy of local infiltration analgesia in surgical wounds with 0.2% ropivacaine (50 mL), ketorolac (15 mg), and adrenaline (0.5 mg) compared with that of local infiltration analgesia combined with continuous infusion of 0.2% ropivacaine as a method of pain control after total hip arthroplasty. We hypothesized that as a component of multimodal analgesia, local infiltration analgesia followed by continuous infusion of ropivacaine would result in reduced postoperative opioid consumption and lower pain scores compared with infiltration alone, and that both of these techniques would be superior to placebo. In this prospective, double-blind, placebo-controlled study, 105 patients were randomized into three groups: Group I, in which patients received infiltration with ropivacaine, ketorolac, and adrenaline followed by continuous infusion of 0.2% ropivacaine at 5 mL/hr; Group II, in which patients received infiltration with ropivacaine, ketorolac, and adrenaline followed by continuous infusion of saline solution at 5 mL/hr; and Group III, in which patients received infiltration with saline solution followed by continuous infusion of saline solution at 5 mL/hr.All patients received celecoxib, pregabalin, and acetaminophen perioperatively and patient-controlled analgesia; surgery was performed under general anesthesia. Before wound closure, the tissues and periarticular space were infiltrated with ropivacaine, ketorolac, and adrenaline or saline solution and a fenestrated catheter was placed. The catheter was attached to a pump prefilled with either 0.2% ropivacaine or saline solution set to infuse at 5 mL/hr.The primary outcome measure was postoperative opioid consumption and the secondary outcome measures were pain scores, adverse side effects, and patient satisfaction. There were no differences between groups in the administration of opioids in the operating room, in the recovery room, or on the surgical floor. The pain scores on recovery room admission and discharge and the floor were low and similar between groups. There were no differences in the incidence of adverse side effects among groups. Patient satisfaction with pain management was similar in all groups. Local infiltration analgesia alone or followed by continuous infusion of ropivacaine as part of multimodal analgesia provides no additional analgesic benefit or reduction in opioid consumption compared with placebo following total hip arthroplasty. Therapeutic level I. See Instructions for Authors for a complete description of levels of evidence.
Pharmacokinetics of Epsilon-Aminocaproic Acid in Neonates
Eaton, Michael P.; Alfieris, George M; Sweeney, Dawn M; Angona, Ronald E; Cholette, Jill M; Venuto, Charles; Anderson, Brian
2016-01-01
Background Antifibrinolytic medications such as epsilon-aminocaproic acid (EACA) are used in pediatric heart surgery to decrease surgical bleeding and transfusion. Dosing schemes for neonates are often based on adult regimens, or are simply empiric, in part due to the lack of neonatal pharmacokinetic information. We sought to determine the pharmacokinetics of EACA in neonates undergoing cardiac surgery and to devise a dosing regimen for this population. Methods Ten neonates undergoing cardiac surgery with cardiopulmonary bypass were given EACA according to standard practice, and blood was drawn at 10 time points to determine drug concentrations. Time-concentration profiles were analyzed using nonlinear mixed effects models. Parameter estimates (standardized to a 70 kg person) were used to develop a dosing regimen intended to maintain a target concentration shown to inhibit fibrinolysis in neonatal plasma (50 mg/L). Results Pharmacokinetics were described using a two compartment model plus an additional compartment for the cardiopulmonary bypass pump. First order elimination was described with a clearance of 5.07 L/h*(WT/70) 0.75. Simulation showed a dosing regimen with a loading dose of 40 mg/kg, and an infusion of 30 mg/kg/h, with a pump prime concentration of 100 mg/L maintained plasma concentrations above 50 mg/L in 90% of neonates during cardiopulmonary bypass surgery. Conclusions EACA clearance, expressed using allometry, is reduced in neonates compared to older children and adults. Loading dose and infusion dose are approximately half those required in children and adults. PMID:25723765
Eaton, Michael P; Alfieris, George M; Sweeney, Dawn M; Angona, Ronald E; Cholette, Jill M; Venuto, Charles; Anderson, Brian
2015-05-01
Antifibrinolytic medications such as ε-aminocaproic acid (EACA) are used in pediatric heart surgery to decrease surgical bleeding and transfusion. Dosing schemes for neonates are often based on adult regimens, or are simply empiric, in part due to the lack of neonatal pharmacokinetic information. The authors sought to determine the pharmacokinetics of EACA in neonates undergoing cardiac surgery and to devise a dosing regimen for this population. Ten neonates undergoing cardiac surgery with cardiopulmonary bypass were given EACA according to standard practice, and blood was drawn at 10 time points to determine drug concentrations. Time-concentration profiles were analyzed using nonlinear mixed effects models. Parameter estimates (standardized to a 70-kg person) were used to develop a dosing regimen intended to maintain a target concentration shown to inhibit fibrinolysis in neonatal plasma (50 mg/l). Pharmacokinetics were described using a two-compartment model plus an additional compartment for the cardiopulmonary bypass pump. First-order elimination was described with a clearance of 5.07 l/h × (WT/70). Simulation showed a dosing regimen with a loading dose of 40 mg/kg and an infusion of 30 mg · kg · h, with a pump prime concentration of 100 mg/l maintained plasma concentrations above 50 mg/l in 90% of neonates during cardiopulmonary bypass surgery. EACA clearance, expressed using allometry, is reduced in neonates compared with older children and adults. Loading dose and infusion dose are approximately half those required in children and adults.
Sudhakaran, Chidambarann; Anjana, Ranjit Mohan; Rao, Kavitha; Unnikrishnan, Ranjit; Suresh, Thangamani; Mohan, Viswanathan
2009-11-01
We aimed to assess the effect of continuous subcutaneous insulin infusion (CSII) therapy in patients with "recalcitrant diabetes" whose glycemia had not been controlled adequately with multiple daily injections of insulin or insulin plus oral hypoglycemic agents. We retrospectively analyzed the medical records of patients with diabetes who were initiated on insulin pump therapy at our center in India between 2002 and 2007. Data analysis included fasting and postprandial blood glucose and glycated hemoglobin (HbA1c) values, insulin requirement, body weight, and the occurrence of hypoglycemia and diabetic ketoacidosis. We studied 33 patients with diabetes (type 1 [n = 17] and type 2 [n = 16]) who were on CSII therapy for a mean duration of 3.4 years. A statistically significant reduction in HbA1c was found after initiating CSII (prepump 10.7% vs. postpump 8.3%, P < 0.001). The reduction was greater in type 1 patients (10.6 +/- 2.1 vs. 8.0 +/- 1.6%) than in type 2 patients (11.0 +/- 2.1 vs. 8.8 +/- 1.4%). There was a reduction in frequency of severe hypoglycemia after starting the CSII pump, and there were no instances of diabetic ketoacidosis. Although HbA1c levels did not reach optimal targets, our data indicate that CSII is an effective therapy for patients with diabetes having recalcitrant diabetes who can afford this treatment and whose glycemia is poorly controlled with conventional therapies.
Matejko, Bartlomiej; Kiec-Wilk, Beata; Szopa, Magdalena; Trznadel Morawska, Iwona; Malecki, Maciej T; Klupa, Tomasz
2015-07-01
Little is known about the impact of sleep duration and late-night snacking on glycemic control in patients with type 1 diabetes using insulin pumps. The aim of the present study was to examine whether late-night eating habits and short sleep duration are associated with glycemic control in continuous subcutaneous insulin infusion-treated type 1 diabetic patients. We included 148 consecutive adult type 1 diabetic subjects using an insulin pump (100 women and 48 men). Participants completed a questionnaire regarding sleep duration (classified as short if ≤6 h) and late-night snacking. Other sources of information included medical records and data from blood glucose meters. Glycemic control was assessed by glycated hemoglobin (HbA1c) levels and mean self-monitoring of blood glucose (SMBG) readings. The mean age of patients was 26 years, mean type 1 diabetes duration was 13.4 years and mean HbA1c level was 7.2%. In a univariate regression analysis, sleep duration was a predictor of both HbA1c (β = 0.51, P = 0.01) and SMBG levels (β = 11.4, P = 0.02). Additionally, an association was found between frequent late-night snacking and higher SMBG readings (often snacking β = 18.1, P = 0.05), but not with increased HbA1c levels. In the multivariate linear regression, independent predictors for HbA1c and SMBG were sleep duration and patient age. In a univariate logistic regression, sleep duration and frequency of late-night snacking were not predictors of whether HbA1c target levels were achieved. Short sleep duration, but not late-night snacking, seems to be associated with poorer glycemic control in type 1 diabetic patients treated with continuous subcutaneous insulin infusion.
James, Steven; Perry, Lin; Gallagher, Robyn; Lowe, Julia
2016-11-01
Technology provides adjuvant and/or alternative approaches to care and may promote self-care, communication, and engagement with health care services. Common recent technologies for diabetes include continuous subcutaneous insulin infusions (insulin pumps), continuous glucose monitoring systems, smartphone and tablet applications, and telehealth (video conferencing). This study reports Australian diabetes educators' intentions and reported professional use of these technologies for people with type 1 diabetes, and factors predictive of this. An anonymous, web-based questionnaire based on the technology acceptance model was distributed to members of the Australian Diabetes Educators Association through their electronic newsletter. Exploratory factor analysis revealed a 5-factor solution comprising confidence and competence, improving clinical practice, preparation (intentions and training), ease of use, and subjective norms. Logistic regression analyses identified factors predicting intention and use of technology. Respondents (n = 228) had high intentions to use technology. The majority reported using continuous subcutaneous insulin infusions, continuous glucose monitoring systems, and applications with patients, but usage was occasional. Confidence and competence independently predicted both intentions and use of all 4 technologies. Preparation (intentions and training) independently predicted use of each technology also. Discrepancies and dissonance appear between diabetes educators' intentions and behavior (intentions to use and reported technology use). Intentions were higher than current use, which was relatively low and not likely to provide significant support to people with type 1 diabetes for disease management, communication, and engagement with health care services. Continuing education and experiential learning may be key in supporting diabetes educators to align their intentions with their practice. © 2016 Diabetes Technology Society.
Diabetes Educators’ Intended and Reported Use of Common Diabetes-Related Technologies
James, Steven; Perry, Lin; Gallagher, Robyn; Lowe, Julia
2016-01-01
Background: Technology provides adjuvant and/or alternative approaches to care and may promote self-care, communication, and engagement with health care services. Common recent technologies for diabetes include continuous subcutaneous insulin infusions (insulin pumps), continuous glucose monitoring systems, smartphone and tablet applications, and telehealth (video conferencing). This study reports Australian diabetes educators’ intentions and reported professional use of these technologies for people with type 1 diabetes, and factors predictive of this. Methods: An anonymous, web-based questionnaire based on the technology acceptance model was distributed to members of the Australian Diabetes Educators Association through their electronic newsletter. Exploratory factor analysis revealed a 5-factor solution comprising confidence and competence, improving clinical practice, preparation (intentions and training), ease of use, and subjective norms. Logistic regression analyses identified factors predicting intention and use of technology. Results: Respondents (n = 228) had high intentions to use technology. The majority reported using continuous subcutaneous insulin infusions, continuous glucose monitoring systems, and applications with patients, but usage was occasional. Confidence and competence independently predicted both intentions and use of all 4 technologies. Preparation (intentions and training) independently predicted use of each technology also. Conclusions: Discrepancies and dissonance appear between diabetes educators’ intentions and behavior (intentions to use and reported technology use). Intentions were higher than current use, which was relatively low and not likely to provide significant support to people with type 1 diabetes for disease management, communication, and engagement with health care services. Continuing education and experiential learning may be key in supporting diabetes educators to align their intentions with their practice. PMID:27179011
Analysis of photovoltaic with water pump cooling by using ANSYS
NASA Astrophysics Data System (ADS)
Syafiqah, Z.; Amin, N. A. M.; Irwan, Y. M.; Shobry, M. Z.; Majid, M. S. A.
2017-10-01
Almost all regions in the world are facing with problem of increasing electricity cost from time to time. Besides, with the mankind’s anxiety about global warming, it has infused an ideology to rapidly move towards renewable energy sources since it is believed to be more reliable and safer. One example of the best alternatives to replace the fossil fuels sourced is solar energy. Photovoltaic (PV) panel is used to convert the sunlight into electricity. Unfortunately, the performance of PV panel can be affected by its operating temperature. With the increment of ambient temperature, the PV panel operating temperature also increase and will affect the performance of PV panel (in terms of power generated). With this concern, a water cooling system was installed on top of PV panel to help reduce the PV panel’s temperature. Five different water mass flow rate is tested due to investigate their impact towards the thermal performance and heat transfer rate.
Medical equipment libraries: implementation, experience and user satisfaction.
Keay, S; McCarthy, J P; Carey-Smith, B E
2015-01-01
The hospital-wide pooling and sharing of certain types of medical equipment can lead to both significant improvements in patient safety and financial advantages when compared with a department or ward-level equipment ownership system. In September 2003, a Medical Equipment Loan Service (MELS) was established, focusing initially on infusion pumps. The aims and expected benefits included; improving availability of equipment for both patients and clinical users, managing and reducing clinical risk, reducing equipment diversity, improving equipment management and reducing the overall cost of equipment provision. A user survey was carried out in 2005 and repeated in 2011. The results showed wide and continued satisfaction with the service. The process and difficulties of establishing the service and its development to include additional types of equipment are described. The benefits of managing medical equipment which is in widespread general use, through a MELS as part of a Clinical Engineering Department, are presented.
Design and Modeling of a Liquid Lithium LiMIT Loop
NASA Astrophysics Data System (ADS)
Szott, Matthew; Christenson, Michael; Stemmley, Steven; Ahn, Chisung; Andruczyk, Daniel; Ruzic, David
2017-10-01
The use of flowing liquid lithium in plasma facing components has been shown to reduce erosion and thermal stress damage, prolong device lifetime, decrease edge recycling, reduce impurities, and increase plasma performance, all while providing a clean and self-healing surface. The Liquid Metal Infused Trench (LiMIT) system has proven the concept of controlled thermoelectric magnetohydrodynamic-driven lithium flow for use in fusion relevant conditions, through tests at UIUC, HT-7, and Magnum PSI. As the use of liquid lithium in fusion devices progresses, emphasis must now be placed on full systems integration of flowing liquid metal concepts. The LiMIT system will be upgraded to include a full liquid lithium loop, which will pump lithium into the fusion device, utilize TEMHD to drive lithium through the vessel, and remove lithium for filtration and degassing. Flow control concepts recently developed at UIUC - including wetting control, dryout control, and flow velocity control - will be tested in conjunction in order to demonstrate a robust system. Lithium loop system requirements, designs, and modeling work will be presented, along with plans for installation and testing on the HIDRA device at UIUC. This work is supported by DOE/ALPS DE-FG02-99ER54515.
Ali, Shayesta; Sofi, Khalid; Dar, Abdul Qayoom
2017-01-01
Pain is a common complaint after surgery and seems to be difficult to manage in children because of fear of complications of pain treatment or misconception that infants and small children do not feel pain at all or feel less pain. A survey reported that 40% of pediatric surgical patients experienced moderate or severe postoperative pain and that more than 75% had insufficient analgesia. Our study was carried to provide continuous infusion of intravenous (i.v.) tramadol alone using a dedicated infusion device Graseby 2100 syringe pump and compared it to a combination of i.v. tramadol infusion and per rectal paracetamol. A total of 124 children aged 1-8 years selected for the study were randomized into two groups using a table of random numbers. Power calculation had suggested a sample size of 62 in each group with a power of 80% and significance level of 5%. Group A comprising 62 children, received i.v. infusion of tramadol in a dose of 0.25 mg/kg/h for 24 h postoperatively. Group B comprising 62 children, received i.v. infusion of tramadol in a dose of 0.25 mg/kg/h for 24 h postoperatively in addition to per rectal suppository of paracetamol in a dose of 90 mg/kg in 24 h (30 mg/kg as first dose followed by 20 mg/kg every 6 hourly for the next 18 h). Postoperatively, patients were observed for 24 h. A statistically significant difference ( P ≤ 0.001) in Face, Legs, Activity, Cry, Consolability pain scores was seen between two groups at 4, 6, and 8 h. Pain scores being less in Group B patients who had received infusion of tramadol and per rectal suppositories of paracetamol compared to Group A patients who received only infusion of tramadol. A statistically significant difference ( P < 0.05) was found in mean analgesic consumption during the first 24 h between the groups. Consumption was more in Group A as compared to Group B. In Group A, 13 patients (21%) required rescue analgesia as compared to only 4 patients (6.5%) in Group B. We recommend use of an infusion of tramadol in a dose of 0.25 mg/kg/h in the first 24 h after surgery, in combination with a regular per rectal paracetamol in a daily dose of 90 mg/kg/day in four divided doses for children after major abdominal surgery. However, a close nursing supervision is essential to increase the safety profile.
Amano, Hikaru; Ogawa, Hidekuni; Maki, Hiromichi; Tsukamoto, Sosuke; Yonezawa, Yoshiharu; Hahn, Allen W; Caldwell, W Morton
2011-01-01
We have been searching for a suitable frequency range for an electrical impedance measurement infusion solution drip monitoring system, which we have previously reported. This electrical impedance, which is formed between two electrodes wrapped around the infusion supply polyvinyl-chloride tube and around the drip chamber, is changed by the growth and fall of each drop of fluid. Thus, the drip rate can be detected by measuring this impedance. However, many different kinds of infusion solutions such as glucose, amino acid, soya oil, and lactated Ringers solution are used in hospitals and care facilities. Therefore, it was necessary to find a suitable frequency for driving the capacitance-change sensor with a wide range of infusion solutions. In this study, the sensor electrical impedance change of 16 infusion solutions was measured from 1 kHz up to 1 MHz. The drip impedance produced by 5% glucose solution, 10% glucose solution and soya oil indicated the maximum sensor output change at 10 kHz, 20 kHz, and 70 kHz, respectively. The other 13 infusion solutions increased up to 10 kHz, and were constant from 10 kHz to 1 MHz. However, the growth, fall, and drip rate of the drops of all the infusion solutions were monitored by measuring the impedance change from 10 kHz to 30 kHz. Our experimental results indicated that most suitable excitation range for the infusion monitoring system is from 10 kHz to 30 kHz. Thus, we can now fine-tune the system for optimal sensing.
NASA Astrophysics Data System (ADS)
Treephak, Kasem; Thongpron, Jutturit; Somsak, Dhirasak; Saelao, Jeerawan; Patcharaprakiti, Nopporn
2015-08-01
In this paper we propose the design and economic evaluation of the water pumping systems for rice cultivation using solar energy, gasoline fuel and compare both systems. The design of the water and gasoline engine pumping system were evaluated. The gasoline fuel cost used in rice cultivation in an area of 1.6 acres. Under same conditions of water pumping system is replaced by the photovoltaic system which is composed of a solar panel, a converter and an electric motor pump which is compose of a direct current (DC) motor or an alternating current (AC) motor with an inverter. In addition, the battery is installed to increase the efficiency and productivity of rice cultivation. In order to verify, the simulation and economic evaluation of the storage energy battery system with batteries and without batteries are carried out. Finally the cost of four solar pumping systems was evaluated and compared with that of the gasoline pump. The results showed that the solar pumping system can be used to replace the gasoline water pumping system and DC solar pump has a payback less than 10 years. The systems that can payback the fastest is the DC solar pumping system without batteries storage system. The system the can payback the slowest is AC solar pumping system with batteries storage system. However, VAC motor pump of 220 V can be more easily maintained than the motor pump of 24 VDC and batteries back up system can supply a more stable power to the pump system.
Abdel-Misih, Sherif R Z; Bloomston, Mark
2010-08-01
Understanding the complexities of the liver has been a long-standing challenge to physicians and anatomists. Significant strides in the understanding of hepatic anatomy have facilitated major progress in liver-directed therapies--surgical interventions, such as transplantation, hepatic resection, hepatic artery infusion pumps, and hepatic ablation, and interventional radiologic procedures, such as transarterial chemoembolization, selective internal radiation therapy, and portal vein embolization. Without understanding hepatic anatomy, such progressive interventions would not be feasible. This article reviews the history, general anatomy, and the classification schemes of liver anatomy and their relevance to liver-directed therapies. Copyright 2010 Elsevier Inc. All rights reserved.
Model-based engineering for medical-device software.
Ray, Arnab; Jetley, Raoul; Jones, Paul L; Zhang, Yi
2010-01-01
This paper demonstrates the benefits of adopting model-based design techniques for engineering medical device software. By using a patient-controlled analgesic (PCA) infusion pump as a candidate medical device, the authors show how using models to capture design information allows for i) fast and efficient construction of executable device prototypes ii) creation of a standard, reusable baseline software architecture for a particular device family, iii) formal verification of the design against safety requirements, and iv) creation of a safety framework that reduces verification costs for future versions of the device software. 1.
Lawton, J; Kirkham, J; Rankin, D; White, D A; Elliott, J; Jaap, A; Smithson, W H; Heller, S
2016-02-01
To explore health professionals' views about insulin pump therapy [continuous subcutaneous insulin infusion (CSII)] and the types of individuals they thought would gain greatest clinical benefit from using this treatment. In-depth interviews with staff (n = 18) who delivered the Relative Effectiveness of Pumps Over MDI and Structured Education (REPOSE) trial. Data were analysed thematically. Staff perceived insulin pumps as offering a better self-management tool to some individuals due to the drip feed of insulin, the ability to alter basal rates and other advanced features. However, staff also noted that, because of the diversity of features on offer, CSII is a more technically complex therapy to execute than multiple daily injections. For this reason, staff described how, alongside clinical criteria, they had tended to select individuals for CSII in routine clinical practice based on their perceptions about whether they possessed the personal and psychological attributes needed to make optimal use of pump technology. Staff also described how their assumptions about personal and psychological suitability had been challenged by working on the REPOSE trial and observing individuals make effective use of CSII who they would not have recommended for this type of therapy in routine clinical practice. Our findings add to those studies that highlight the difficulties of using patient characteristics and variables to predict clinical success using CSII. To promote equitable access to CSII, attitudinal barriers and prejudicial assumptions amongst staff about who is able to make effective use of CSII may need to be addressed. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.
Prolonged striatal disinhibition as a chronic animal model of tic disorders.
Vinner, Esther; Israelashvili, Michal; Bar-Gad, Izhar
2017-12-01
Experimental findings and theoretical models have associated Tourette syndrome with abnormal striatal inhibition. The expression of tics, the hallmark symptom of this disorder, has been transiently induced in non-human primates and rodents by the injection of GABA A antagonists into the striatum, leading to temporary disinhibition. The novel chronic model of tic expression utilizes mini-osmotic pumps implanted subcutaneously in the rat's back for prolonged infusion of bicuculline into the dorsolateral striatum. Tics were expressed on the contralateral side to the infusion over a period of multiple days. Tic expression was stable, and maintained similar properties throughout the infusion period. Electrophysiological recordings revealed the existence of tic-related local field potential spikes and individual neuron activity changes that remained stable throughout the infusion period. The striatal disinhibition model provides a unique combination of face validity (tic expression) and construct validity (abnormal striatal inhibition) but is limited to sub-hour periods. The new chronic model extends the period of tic expression to multiple days and thus enables the study of tic dynamics and the effects of behavior and pharmacological agents on tic expression. The chronic model provides similar behavioral and neuronal correlates of tics as the acute striatal disinhibition model but over prolonged periods of time, thus providing a unique, basal ganglia initiated model of tic expression. Chronic expression of symptoms is the key to studying the time varying properties of Tourette syndrome and the effects of multiple internal and external factors on this disorder. Copyright © 2017 Elsevier B.V. All rights reserved.
Morzelle, Maressa Caldeira; Salgado, Jocelem Mastrodi; Telles, Milena; Mourelle, Danilo; Bachiega, Patricia; Buck, Hudson Sousa
2016-01-01
Alzheimer’s disease is a chronic and degenerative condition that had no treatment until recently. The current therapeutic strategies reduce progression of the disease but are expensive and commonly cause side effects that are uncomfortable for treated patients. Functional foods to prevent and/or treat many conditions, including neurodegenerative diseases, represent a promising field of study currently gaining attention. To this end, here we demonstrate the effects of pomegranate (Punica granatum) peel extract (PPE) regarding spatial memory, biomarkers of neuroplasticity, oxidative stress and inflammation in a mouse model of neurodegeneration. Male C57Bl/6 mice were chronically infused for 35 days with amyloid-β peptide 1–42 (Aβ) or vehicle (control) using mini-osmotic pumps. Another group, also infused with Aβ, was treated with PPE (p.o.– βA+PPE, 800 mg/kg/day). Spatial memory was evaluated in the Barnes maze. Animals treated with PPE and in the control group exhibited a reduction in failure to find the escape box, a finding that was not observed in the Aβ group. The consumption of PPE reduced amyloid plaque density, increased the expression of neurotrophin BDNF and reduced the activity of acetylcholinesterase enzyme. A reduction in lipid peroxidation and in the concentration of the pro-inflammatory cytokine TNF-α was also observed in the PPE group. No hepatic lesions were observed in animals treated with PPE. In conclusion, administration of pomegranate peel extract has neuroprotective effects involving multiple mechanisms to prevent establishment and progression of the neurodegenerative process induced by infusion with amyloid-β peptide in mice. PMID:27829013
Intraarterial infusion chemotherapy with lipioclol-CDDP suspension for hepatocellular carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamoto, Kazuhiro; Shimizu, Tadafumi; Narabayashi, Isamu
Purpose: To quantitatively evaluate the usefulness of lipiodol-CDDP suspension (LCS) chemotherapy in hepatocellular carcinoma (HCC).Methods: CDDP (cis-diamminedichloroplatinum) powder was prepared by removing the water and NaCl from aqueous CDDP. Two quantities of prepared CDDP powder, 10 mg and 20 mg, were mixed with 1 ml each of iopamidol 300 mgl/ml (IP300) and lipiodol (LPD) using a high pressure pumping method, thus producing LCS. Thirty-two patients with HCC, who had good renal function [creatinine clearance (Ccr) 50 ml/min or more], received additional intraarterial infusion chemotherapy with LCS or LCS alone.Results: The most frequently observed CDDP powder sizes were 5.95-10.90 {mu}m (average:more » 11.59 {mu}m). The LCS obtained demonstrated a suspension of 2-12 {mu}m (average 3.69 {mu}m) immediately after mixing, and no significant changes were observed in LCS particle sizes 3 hr after mixing. Moreover, the sustained release with LCS was observed for up to 3 hr. Meanwhile, the peripheral free platinum concentration between intraarterial infusion chemotherapy with LCS and intraarterial infusion with the aqueous solution of CDDP, with respect to variance residence time (VRT), showed a significant difference, with a p value of 0.0382. The survival rate was 89.84% at 1 year, 73.787c at 2 years, and 68.51% at 3 years. Furthermore, the platinum concentration in the tumor was 25-95 times the concentration in the surrounding liver parenchyma.Conclusion: Good clinical results can be expected by applying LCS to HCC.« less
Intraarterial Infusion Chemotherapy with Lipiodol-CDDP Suspension for Hepatocellular Carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamoto, Kazuhiro; Shimizu, Tadafumi; Narabayashi, Isamu
Purpose: To quantitatively evaluate the usefulness of lipiodol-CDDP suspension (LCS) chemotherapy in hepatocellular carcinoma (HCC).Methods: CDDP (cis-diamminedichloroplatinum) powder was prepared by removing the water and NaCl from aqueous CDDP. Two quantities of prepared CDDP powder, 10 mg and 20 mg, were mixed with 1 ml each of iopamidol 300 mgI/ml (IP300) and lipiodol (LPD) using a high pressure pumping method, thus producing LCS. Thirty-two patients with HCC, who had good renal function [creatinine clearance (Ccr) 50 ml/min or more], received additional intraarterial infusion chemotherapy with LCS or LCS alone.Results: The most frequently observed CDDP powder sizes were 5.95-10.90 {mu}m (average:more » 11.59 {mu}m). The LCS obtained demonstrated a suspension of 2-12 {mu}m (average 3.69 {mu}m) immediately after mixing, and no significant changes were observed in LCS particle sizes 3 hr after mixing. Moreover, the sustained release with LCS was observed for up to 3 hr. Meanwhile, the peripheral free platinum concentration between intraarterial infusion chemotherapy with LCS and intraarterial infusion with the aqueous solution of CDDP, with respect to variance residence time (VRT), showed a significant difference, with a p value of 0.0382. The survival rate was 89.84% at 1 year, 73.78% at 2 years, and 68.51% at 3 years. Furthermore, the platinum concentration in the tumor was 25-95 times the concentration in the surrounding liver parenchyma.Conclusion: Good clinical results can be expected by applying LCS to HCC.« less
The effects of angiotensin II on blood perfusion in the rat renal papilla
Walker, L L; Rajaratne, A A J; Blair-West, J R; Harris, P J
1999-01-01
Systemic infusion of angiotensin II (AII) increased papillary blood perfusion (PBP) measured by laser-Doppler flowmetry in rats, aged about 5 weeks. The mechanisms involved in this response were determined by infusion of AII in the presence of systemic doses of losartan (a type 1 AII receptor antagonist), HOE-140 (a bradykinin B2 receptor antagonist), and an inhibitor of NO production - Nω -nitro-L-arginine (NOLA). Mean arterial blood pressure (MAP) and PBP increased in a dose-dependent manner in response to intravenous infusions of AII. Infusion of losartan abolished these responses to AII but HOE-140 was without effect. Infusion of NOLA abolished the increase in PBP but did not affect the pressor response to AII. Systemic infusion of sodium nitroprusside restored the response to AII in experiments with NOLA infusion. The results indicate that the increase in PBP caused by AII is mediated via angiotensin AT1 receptors and does not involve bradykinin B2 receptors. The AII-induced increase in PBP is dependent upon the presence of NO, thus providing a mechanism for maintenance of papillary perfusion in the face of generalized renal vasoconstriction due to AII. PMID:10432357
Witkowski, Maria Carolina; de Moraes, Maria Antonieta P.; Firpo, Cora Maria F.
2013-01-01
OBJECTIVE: To compare two systems of arterial catheters maintenance in postoperative pediatric surgery using intermittent or continuous infusion of heparin solution and to analyze adverse events related to the site of catheter insertion and the volume of infused heparin solution. METHODS: Randomized control trial with 140 patients selected for continuous infusion group (CIG) and intermittent infusion group (IIG). The variables analyzed were: type of heart disease, permanence time and size of the catheter, insertion site, technique used, volume of heparin solution and adverse events. The descriptive variables were analyzed by Student's t-test and the categorical variables, by chi-square test, being significant p<0.05. RESULTS: The median age was 11 (0-22) months, and 77 (55%) were females. No significant differences between studied variables were found, except for the volume used in CIG (12.0±1.2mL/24 hours) when compared to IIG (5.3±3.5mL/24 hours) with p<0.0003. CONCLUSIONS: The continuous infusion system and the intermittent infusion of heparin solution can be used for intra-arterial catheters maintenance in postoperative pediatric surgery, regardless of patient's clinical and demographic characteristics. Adverse events up to the third postoperative day occurred similarly in both groups. However, the intermittent infusion system usage in underweight children should be considered, due to the lower volume of infused heparin solution [ClinicalTrials.gov Identifier: NCT01097031]. PMID:24473958
Using Zigbee to integrate medical devices.
Frehill, Paul; Chambers, Desmond; Rotariu, Cosmin
2007-01-01
Wirelessly enabling Medical Devices such as Vital Signs Monitors, Ventilators and Infusion Pumps allows central data collection. This paper discusses how data from these types of devices can be integrated into hospital systems using wireless sensor networking technology. By integrating devices you are protecting investment and opening up the possibility of networking with similar devices. In this context we present how Zigbee meets our requirements for bandwidth, power, security and mobility. We have examined the data throughputs for various medical devices, the requirement of data frequency, security of patient data and the logistics of moving patients while connected to devices. The paper describes a new tested architecture that allows this data to be seamlessly integrated into a User Interface or Healthcare Information System (HIS). The design supports the dynamic addition of new medical devices to the system that were previously unsupported by the system. To achieve this, the hardware design is kept generic and the software interface for different types of medical devices is well defined. These devices can also share the wireless resources with other types of sensors being developed in conjunction on this project such as wireless ECG (Electrocardiogram) and Pulse-Oximetry sensors.
Design and development of a manual pump for bolus enteral nutrition.
Romano-García, Judit; Fernández-Morera, Juan Luis
2018-02-01
Enteral nutrition (EN) is based on administration of liquid solutions into the gastrointestinal tract using a tube. After identifying unsolved practical difficulties in administration of EN using volume syringes, a new device to overcome such technical difficulties was proposed. Specific technologies (CAD, 3D printing) were used in collaboration with the PRODINTEC Foundation (Gijón, Asturias). Clarke Modet, a law firm specialized in intellectual property, provided legal advice on formulas for legal protection of the invention. The resulting device is a manual pump for infusion of EN to patients that solves previously identified problems and is highly functional and compact. It would allow for comfortable and safe administration of solutions. Integration of a bottle into the device itself and pump dimensions facilitate transport and patient mobility. According to the described configuration, this invention has many advantages over the previously known procedures, such as a simpler administration within the field of intermittent EN, improving the standard nutritional support technique, which in this case is use of volume syringes. This would facilitate the work of caregivers while promoting patient self-care and autonomy. The pump was accredited novelty of design, inventive activity and industrial exploitation potential by the European Patent Office (EPO), to which a patent has been requested. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.
Karnik, Priyanka Pradeep; Dave, Nandini Malay; Garasia, Madhu
2018-01-01
The stripping of the densely innervated and inflamed parietal pleura in empyema during video-assisted thoracoscopic surgery (VATS) decortication can lead to significant pain and major postoperative respiratory compromise. Hence, we compared the analgesic efficacy of continuous epidural infusion versus local infiltration and systemic opioids in children undergoing VATS decortications. Following ethics approval and informed consent, forty patients from 1 to 12 years of age were randomized into two groups, Group E (epidural) and Group L (local infiltration) after induction of anesthesia. In Group E, a thoracic epidural catheter was inserted between T4 and T8. A bolus dose of 0.5 ml/kg of 0.25% injection bupivacaine was given epidurally before incision. Postoperatively, the patients received epidural infusion with bupivacaine and fentanyl up to 48 h using an elastomeric balloon pump. In Group L, patients received local infiltration of bupivacaine (2 mg/kg) and lignocaine (5 mg/kg) at the port sites before incision and at the end of surgery. They also received injection tramadol 1 mg/kg intravenously TDS with thrice daily postoperatively. The pain scores (Face, Legs, Activity, Cry, Consolability/ Wong-Baker FACES scale) were assessed every 4 h on the 1 st day and 6 h on the 2 nd day. Injection diclofenac 1 mg/kg intravenous was used as a rescue analgesic for pain scores more than 4. Side effects such as nausea, vomiting, constipation, and motor blockade were noted. Quantitative and categorical data were assessed using t -test and Chi-square test, respectively. The pain scores were lower in the epidural group than in the local infiltration group at 0, 4, and 20 h postoperatively ( P = 0.001, 0.01, and 0.038, respectively). Seventeen out of nineteen patients required rescue analgesia in the local infiltration group in the postoperative period as compared to five patients in the epidural group with a P value of 0.000081. Epidural analgesia can be considered as an effective modality of reducing pain in patients undergoing VATS decortication for empyema in pediatric patients.
Blood Pressure-Lowering Effect of Orally Ingested Nitrite Is Abolished by a Proton Pump Inhibitor.
Montenegro, Marcelo F; Sundqvist, Michaela L; Larsen, Filip J; Zhuge, Zhengbing; Carlström, Mattias; Weitzberg, Eddie; Lundberg, Jon O
2017-01-01
Inorganic nitrate and nitrite from dietary and endogenous sources are metabolized to NO and other bioactive nitrogen oxides that affect blood pressure. The mechanisms for nitrite bioactivation are unclear, but recent studies in rodents suggest that gastric acidity may influence the systemic effects of this anion. In a randomized, double-blind, placebo-controlled crossover study, we tested the effects of a proton pump inhibitor on the acute cardiovascular effects of nitrite. Fifteen healthy nonsmoking, normotensive subjects, aged 19 to 39 years, were pretreated with placebo or esomeprazole (3×40 mg) before ingesting sodium nitrite (0.3 mg kg -1 ), followed by blood pressure monitoring. Nitrite reduced systolic blood pressure by a maximum of 6±1.3 mm Hg when taken after placebo, whereas pretreatment with esomeprazole blunted this effect. Peak plasma nitrite, nitrate, and nitroso species levels after nitrite ingestion were similar in both interventions. In 8 healthy volunteers, we then infused increasing doses of sodium nitrite (1, 10, and 30 nmol kg -1 min -1 ) intravenously. Interestingly, although plasma nitrite peaked at similar levels as with orally ingested nitrite (≈1.8 µmol/L), no changes in blood pressure were observed. In rodents, esomeprazole did not affect the blood pressure response to the NO donor, DEA NONOate, or vascular relaxation to nitroprusside and acetylcholine, demonstrating an intact downstream NO-signaling pathway. We conclude that the acute blood pressure-lowering effect of nitrite requires an acidic gastric environment. Future studies will reveal if the cardiovascular complications associated with the use of proton pump inhibitors are linked to interference with the nitrate-nitrite-NO pathway. © 2016 American Heart Association, Inc.
Davis, Stephen N; Horton, Edward S; Battelino, Tadej; Rubin, Richard R; Schulman, Kevin A; Tamborlane, William V
2010-04-01
Sensor-augmented pump therapy (SAPT) integrates real-time continuous glucose monitoring (RT-CGM) with continuous subcutaneous insulin infusion (CSII) and offers an alternative to multiple daily injections (MDI). Previous studies provide evidence that SAPT may improve clinical outcomes among people with type 1 diabetes. Sensor-Augmented Pump Therapy for A1c Reduction (STAR) 3 is a multicenter randomized controlled trial comparing the efficacy of SAPT to that of MDI in subjects with type 1 diabetes. Subjects were randomized to either continue with MDI or transition to SAPT for 1 year. Subjects in the MDI cohort were allowed to transition to SAPT for 6 months after completion of the study. SAPT subjects who completed the study were also allowed to continue for 6 months. The primary end point was the difference between treatment groups in change in hemoglobin A1c (HbA1c) percentage from baseline to 1 year of treatment. Secondary end points included percentage of subjects with HbA1c < or =7% and without severe hypoglycemia, as well as area under the curve of time spent in normal glycemic ranges. Tertiary end points include percentage of subjects with HbA1c < or =7%, key safety end points, user satisfaction, and responses on standardized assessments. A total of 495 subjects were enrolled, and the baseline characteristics similar between the SAPT and MDI groups. Study completion is anticipated in June 2010. Results of this randomized controlled trial should help establish whether an integrated RT-CGM and CSII system benefits patients with type 1 diabetes more than MDI.
Canine spontaneous glioma: A translational model system for convection-enhanced delivery
Dickinson, Peter J.; LeCouteur, Richard A.; Higgins, Robert J.; Bringas, John R.; Larson, Richard F.; Yamashita, Yoji; Krauze, Michal T.; Forsayeth, John; Noble, Charles O.; Drummond, Daryl C.; Kirpotin, Dmitri B.; Park, John W.; Berger, Mitchel S.; Bankiewicz, Krystof S.
2010-01-01
Canine spontaneous intracranial tumors bear striking similarities to their human tumor counterparts and have the potential to provide a large animal model system for more realistic validation of novel therapies typically developed in small rodent models. We used spontaneously occurring canine gliomas to investigate the use of convection-enhanced delivery (CED) of liposomal nanoparticles, containing topoisomerase inhibitor CPT-11. To facilitate visualization of intratumoral infusions by real-time magnetic resonance imaging (MRI), we included identically formulated liposomes loaded with Gadoteridol. Real-time MRI defined distribution of infusate within both tumor and normal brain tissues. The most important limiting factor for volume of distribution within tumor tissue was the leakage of infusate into ventricular or subarachnoid spaces. Decreased tumor volume, tumor necrosis, and modulation of tumor phenotype correlated with volume of distribution of infusate (Vd), infusion location, and leakage as determined by real-time MRI and histopathology. This study demonstrates the potential for canine spontaneous gliomas as a model system for the validation and development of novel therapeutic strategies for human brain tumors. Data obtained from infusions monitored in real time in a large, spontaneous tumor may provide information, allowing more accurate prediction and optimization of infusion parameters. Variability in Vd between tumors strongly suggests that real-time imaging should be an essential component of CED therapeutic trials to allow minimization of inappropriate infusions and accurate assessment of clinical outcomes. PMID:20488958
Park, Kyungnam; Lee, Jangyoung; Kim, Soo-Young; Kim, Jinwoo; Kim, Insoo; Choi, Seung Pill; Jeong, Sikyung; Hong, Sungyoup
2013-06-01
This study assessed the method of fluid infusion control using an IntraVenous Infusion Controller (IVIC). Four methods of infusion control (dial flow controller, IV set without correction, IV set with correction and IVIC correction) were used to measure the volume of each technique at two infusion rates. The infused fluid volume with a dial flow controller was significantly larger than other methods. The infused fluid volume was significantly smaller with an IV set without correction over time. Regarding the concordance correlation coefficient (CCC) of infused fluid volume in relation to a target volume, IVIC correction was shown to have the highest level of agreement. The flow rate measured in check mode showed a good agreement with the volume of collected fluid after passing through the IV system. Thus, an IVIC could assist in providing an accurate infusion control. © 2013 Wiley Publishing Asia Pty Ltd.
Fujiwara, Tatsuki; Nagaoka, Eiki; Watanabe, Taiju; Miyagi, Naoto; Kitao, Takashi; Sakota, Daisuke; Mamiya, Taichi; Shinshi, Tadahiko; Arai, Hirokuni; Takatani, Setsuo
2013-05-01
We have evaluated the feasibility of a newly developed single-use, magnetically levitated centrifugal blood pump, MedTech Mag-Lev, in a 3-week extracorporeal membrane oxygenation (ECMO) study in calves against a Medtronic Bio-Pump BPX-80. A heparin- and silicone-coated polypropylene membrane oxygenator MERA NHP Excelung NSH-R was employed as an oxygenator. Six healthy male Holstein calves with body weights of about 100 kg were divided into two groups, four in the MedTech group and two in the Bio-Pump group. Under general anesthesia, the blood pump and oxygenator were inserted extracorporeally between the main pulmonary artery and the descending aorta via a fifth left thoracotomy. Postoperatively, both the pump and oxygen flow rates were controlled at 3 L/min. Heparin was continuously infused to maintain the activated clotting time at 200-240 s. All the MedTech ECMO calves completed the study duration. However, the Bio-Pump ECMO calves were terminated on postoperative days 7 and 10 because of severe hemolysis and thrombus formation. At the start of the MedTech ECMO, the pressure drop across the oxygenator was about 25 mm Hg with the pump operated at 2800 rpm and delivering 3 L/min flow. The PO2 of the oxygenator outlet was higher than 400 mm Hg with the PCO2 below 45 mm Hg. Hemolysis and thrombus were not seen in the MedTech ECMO circuits (plasma-free hemoglobin [PFH] < 5 mg/dL), while severe hemolysis (PFH > 20 mg/dL) and large thrombus were observed in the Bio-Pump ECMO circuits. Plasma leakage from the oxygenator did not occur in any ECMO circuits. Three-week cardiopulmonary support was performed successfully with the MedTech ECMO without circuit exchanges. The MedTech Mag-Lev could help extend the durability of ECMO circuits by the improved biocompatible performances. © 2013, Copyright the Authors. Artificial Organs © 2013, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Isoda, Kikuo; Akita, Koji; Kitamura, Kenichi; Sato-Okabayashi, Yayoi; Kadoguchi, Tomoyasu; Isobe, Sarasa; Ohtomo, Fumie; Sano, Motoaki; Shimada, Kazunori; Iwakura, Yoichiro; Daida, Hiroyuki
2018-06-05
Angiotensin II (Ang II) activates components of the inflammatory cascade, which promotes hypertension and development of abdominal aortic aneurysm (AAA). This study aimed to elucidate the effects of an IL-1 receptor antagonist (IL-1Ra) and an anti-IL-1β antibody (01BSUR) on Ang II-induced AAA. Male wild-type (WT) and IL-1Ra-deficient (IL-1Ra - / - ) mice were infused with Ang II (1000 ng/kg/min) using subcutaneous osmotic pumps for 28 days. Fourteen days post-infusion, both systolic blood pressure (SBP) (Ang II-treated IL-1Ra - / - :149 ± 2 vs. Ang II-treated WT:126 ± 3 mm Hg, p < 0.001) and abdominal aortic width (0.94 ± 0.09 vs. 0.49 ± 0.03 mm, p < 0.001) were significantly higher in IL-1Ra - / - mice than in WT mice. Because 28-day infusion with Ang II in IL-1Ra -/- mice significantly increased the occurrence of fatal aortic rupture (89% vs. 6%, p < 0.0001), both types of mice were infused with Ang II for only 14 days, and histological analyses were performed at 28 days. Interestingly, AAA increased more significantly in IL-1Ra - / - mice than in WT mice (p < 0.001), although SBP did not differ at 28 days in IL-1Ra - / - and WT mice (117 ± 4 vs. 115 ± 3 mm Hg, p = 0.71 (after cessation of Ang II infusion)). Histological analyses showed numerous inflammatory cells around the abdominal aorta in IL-1Ra - / - mice, but not in WT mice. Finally, compared with IgG2a treatment, treatment with 01BSUR decreased Ang II-induced AAA in IL-1Ra - / - mice. The present study demonstrates that inhibition of IL-1β significantly suppresses AAA formation after Ang II infusion, suggesting that suppression of IL-1β may provide an additional strategy to protect against AAA in hypertensive patients. Copyright © 2017 Elsevier B.V. All rights reserved.
Hejtmanek, Michael R; Harvey, Tracy D; Bernards, Christopher M
2011-01-01
To minimize the frequency that intrathecal pumps require refilling, drugs are custom compounded at very high concentrations. Unfortunately, the baricity of these custom solutions is unknown, which is problematic, given baricity's importance in determining the spread of intrathecally administered drugs. Consequently, we measured the density and calculated the baricity of clinically relevant concentrations of multiple drugs used for intrathecal infusion. Morphine, clonidine, bupivacaine, and baclofen were weighed to within 0.0001 g and diluted in volumetric flasks to produce solutions of known concentrations (morphine 1, 10, 25, and 50 mg/mL; clonidine 0.05, 0.5, 1, and 3 mg/mL; bupivacaine 2.5, 5, 10, and 20 mg/mL; baclofen 1, 1.5, 2, and 4 mg/mL). The densities of the solutions were measured at 37°C using the mechanical oscillation method. A "best-fit" curve was calculated for plots of concentration versus density for each drug. All prepared solutions of clonidine and baclofen were hypobaric. Higher concentrations of morphine and bupivacaine were hyperbaric, whereas lower concentrations were hypobaric. The relationship between concentration and density is linear for morphine (r > 0.99) and bupivacaine (r > 0.99) and logarithmic for baclofen (r = 0.96) and clonidine (r = 0.98). This is the first study to examine the relationship between concentration and density for custom drug concentrations commonly used in implanted intrathecal pumps. We calculated an equation that defines the relationship between concentration and density for each drug. Using these equations, clinicians can calculate the density of any solution made from the drugs studied here.
Watanabe, Sharon; Pereira, Jose; Tarumi, Yoko; Hanson, John; Bruera, Eduardo
2008-05-01
ABSTRACT Although the preferred route of opioid administration is oral, patients with cancer often require an alternative route. Options include continuous subcutaneous infusion (CSCI) or regularly scheduled intermittent subcutaneous injections (ISCI). CSCI maintains steady drug levels, theoretically avoiding the "bolus effect" of nausea and sedation immediately post-dose, and breakthrough pain prior to the next dose. However, portable infusion pumps can be costly to use. The Edmonton Injector is an inexpensive portable device for ISCI. CSCI and ISCI have not been directly compared. The objective of this trial was to compare CSCI and ISCI of opioid for treatment of cancer pain. Patients were recruited from two tertiary palliative care units. Eligibility criteria included stable cancer pain requiring opioid therapy, need for parenteral route, and normal cognition. Patients were randomly assigned to receive opioid by CSCI by portable pump or ISCI by Edmonton Injector for 48 hours, followed by crossover to the alternative modality for 48 hours. During each phase, placebo was administered by the alternative modality. The study was closed after 12 patients were entered, due to slow accrual. Eleven patients completed the study. There were no differences between CSCI and ISCI in mean visual analogue score (VAS) for pain, nausea or drowsiness; categorical rating score of pain; number of breakthrough opioid doses per day; global rating of treatment effectiveness; or adverse effects. In all cases, patients and investigators expressed no preference for one modality over another. Further research is required to confirm that opioid administration by CSCI and ISCI provide similar analgesic and adverse effects.
Patient Preferences for Device-Aided Treatments Indicated for Advanced Parkinson Disease.
Marshall, Thomas; Pugh, Amy; Fairchild, Angelyn; Hass, Steven
2017-12-01
Effective treatment for advanced Parkinson disease (PD) uncontrolled with oral medication includes device-aided therapies such as deep brain stimulation (DBS) and continuous levodopa-carbidopa infusion to the duodenum via a portable pump. Our objective was to quantify patient preferences for attributes of these device-aided treatments. We administered a Web-enabled survey to 401 patients in the United States. A discrete-choice experiment (DCE) was used to evaluate patients' willingness to accept tradeoffs among efficacy, tolerability, and convenience of alternative treatments. DCE data were analyzed using random-parameters logit. Best-worst scaling (BWS) was used to elicit the relative importance of device-specific attributes. Conditional logit was used to analyze the BWS data. We tested for differences in preferences among subgroups of patients. Improving ability to think clearly was twice as important as a 6-hour-per-day improvement in control of movement symptoms. After controlling for efficacy, treatment delivered via portable infusion pump was preferred over DBS, and both devices were preferred to oral therapy with poor symptom control. Patients were most concerned about device attributes relating to risk of stroke, difficulty thinking, and neurosurgery. Avoiding surgery to insert a wire in the brain was more important than avoiding surgery to insert a tube into the small intestine. Some differences in preferences among subgroups were statistically, but not qualitatively, significant. This study clarifies the patient perspective in therapeutic choices for advanced PD. These findings may help improve communication between patients and providers and also provide evidence on patient preferences to inform regulatory and access decisions. Copyright © 2017. Published by Elsevier Inc.
Numerical Simulation of Tubular Pumping Systems with Different Regulation Methods
NASA Astrophysics Data System (ADS)
Zhu, Honggeng; Zhang, Rentian; Deng, Dongsheng; Feng, Xusong; Yao, Linbi
2010-06-01
Since the flow in tubular pumping systems is basically along axial direction and passes symmetrically through the impeller, most satisfying the basic hypotheses in the design of impeller and having higher pumping system efficiency in comparison with vertical pumping system, they are being widely applied to low-head pumping engineering. In a pumping station, the fluctuation of water levels in the sump and discharge pool is most common and at most time the pumping system runs under off-design conditions. Hence, the operation of pump has to be flexibly regulated to meet the needs of flow rates, and the selection of regulation method is as important as that of pump to reduce operation cost and achieve economic operation. In this paper, the three dimensional time-averaged Navier-Stokes equations are closed by RNG κ-ɛ turbulent model, and two tubular pumping systems with different regulation methods, equipped with the same pump model but with different designed system structures, are numerically simulated respectively to predict the pumping system performances and analyze the influence of regulation device and help designers make final decision in the selection of design schemes. The computed results indicate that the pumping system with blade-adjusting device needs longer suction box, and the increased hydraulic loss will lower the pumping system efficiency in the order of 1.5%. The pumping system with permanent magnet motor, by means of variable speed regulation, obtains higher system efficiency partly for shorter suction box and partly for different structure design. Nowadays, the varied speed regulation is realized by varied frequency device, the energy consumption of which is about 3˜4% of output power of the motor. Hence, when the efficiency of variable frequency device is considered, the total pumping system efficiency will probably be lower.
Endogenous Opiate System and Systematic Desensitization.
ERIC Educational Resources Information Center
Egan, Kelly J.; And Others
1988-01-01
Administered intravenous infusions to phobic patients prior to systematic desensitization. Saline-infused subjects significantly demonstrated the predicted symptom decrease in response to systematic desensitization, whereas naloxone-infused subjects showed no change. Subject reports and psychophysiological measures of arousal indicated no…
Findings from the ISMP Medication Safety Self-Assessment for hospitals.
Smetzer, Judy L; Vaida, Allen J; Cohen, Michael R; Tranum, Diane; Pittman, Mary A; Armstrong, Carl W
2003-11-01
Hospital medication practices should be assessed, awareness of the characteristics of a safe medication system heightened, and baseline data to identify national priorities established. A cross-sectional survey of U.S. hospitals (N = 6,180) was conducted in May 2000. The survey instrument contained 194 self-assessment items organized into 20 core characteristics and 10 larger domains. Hospitals were asked to voluntarily submit their confidential assessment data to the Institute for Safe Medication Practices (ISMP) for aggregate analysis. A weighting structure was applied to the individual items and used to calculate core characteristic scores, domain scores, and overall self-assessment scores. These scores were then compared to identify areas most in need of improvement. The 1,435 participating hospitals scored highest in domains related to drug storage and distribution; environmental factors; infusion pumps; and medication labeling, packaging, and nomenclature issues. These hospitals scored lowest in domains related to accessible patient information, communication of medication orders, patient education, and quality processes such as double-check systems and organizational culture. Enormous opportunities exist to improve medication safety, especially in domains related to culture, information management, and communication.
Perraudin, Clemence; Bourdin, Aline; Spertini, Francois; Berger, Jérôme; Bugnon, Olivier
2016-07-01
Home-based subcutaneous immunoglobulin (SCIg) therapy is an alternative to hospital-based intravenous infusions (IVIg). However, SCIg requires patient training and long-term support to ensure proper adherence, optimal efficacy and safety. We evaluated if switching patients to home-based SCIg including an interprofessional drug therapy management program (physician, community pharmacist and nurse) would be cost-effective within the Swiss healthcare system. A 3-year cost-minimization analysis was performed from a societal perspective comparing monthly IVIg in an outpatient clinic and home-based weekly SCIg including an interprofessional program. Healthcare costs (immunoglobulin, professional time, infusion pump and disposables) were derived from administrative data. Transportation and productivity loss were estimated by expert opinion. The results were expressed in Swiss francs (CHF) and converted to Euros and US dollars (1 CHF = 0.92€, 1 CHF = $1.02; www.xe.com , 12/14/2015). Under base case assumptions, SCIg was estimated to cost 35,862 CHF (33,134€; $36,595) per patient during the first year and 30,309 CHF (28,004€; $30,929) in subsequent years versus 35,370 CHF (32,679€; $36,095) per year for IVIg. The total savings from switching to SCIg with the interprofessional program were 9630 CHF (8897€; $9828) per patient over 3 years. The results were relatively sensitive to the cost per gram of IgG, the cost of equipment and the annual number of infusions. Home-based SCIg including an interprofessional therapy management program may be an efficient alternative for patients. The program provides long-term support from self-administration training to the responsible use of therapy (proper adherence, optimal efficacy and safety). Over the short term, additional costs from purchasing equipment and the drug therapy management program were offset by avoiding hospital costs.
Funakoshi, Kouta; Hosokawa, Kazuya; Kishi, Takuya; Ide, Tomomi; Sunagawa, Kenji
2014-01-01
Patients with heart failure and preserved ejection fraction (HFpEF) are supersensitive to volume overload, and a striking increase in left atrial pressure (LAP) often occurs transiently and is rapidly resolved by intravascular volume reduction. The arterial baroreflex is a powerful regulator of intravascular stressed blood volume. We examined whether arterial baroreflex failure (FAIL) mimicked by constant carotid sinus pressure (CSP) causes a striking increase in LAP and systemic arterial pressure (AP) by volume loading in rats with normal left ventricular (LV) function. In anesthetized Sprague-Dawley rats, we isolated bilateral carotid sinuses and controlled CSP by a servo-controlled piston pump. We mimicked the normal arterial baroreflex by matching CSP to instantaneous AP and FAIL by maintaining CSP at a constant value regardless of AP. We infused dextran stepwise (infused volume [Vi]) until LAP reached 15 mm Hg and obtained the LAP-Vi relationship. We estimated the critical Vi as the Vi at which LAP reached 20 mm Hg. In FAIL, critical Vi decreased markedly from 19.4 ± 1.6 mL/kg to 15.6 ± 1.6 mL/kg (P < .01), whereas AP at the critical Vi increased (194 ± 6 mm Hg vs 163 ± 6 mm Hg; P < .01). We demonstrated that an artificial arterial baroreflex system we recently developed could fully restore the physiologic volume intolerance in the absence of native arterial baroreflex. Arterial baroreflex failure induces striking volume intolerance in the absence of LV dysfunction and may play an important role in the pathogenesis of acute heart failure, especially in states of HFpEF. Copyright © 2014 Elsevier Inc. All rights reserved.
Wu, Mei-ping; Zhang, Yi-shuai; Xu, Xiangbin; Zhou, Qian
2017-01-01
Purpose Pathological cardiac remodeling, characterized by cardiac hypertrophy and fibrosis, is a pathological feature of many cardiac disorders that leads to heart failure and cardiac arrest. Vinpocetine, a derivative of the alkaloid vincamine, has been used for enhancing cerebral blood flow to treat cognitive impairment. However, its role in pathological cardiac remodeling remains unknown. The aim of this study is to examine the effect of vinpocetine on pathological cardiac remodeling induced by chronic stimulation with angiotensin II (Ang II). Methods Mice received Ang II infusion via osmotic pumps in the presence of vehicle or vinpocetine. Cardiac hypertrophy and fibrosis were assessed by morphological, histological, and biochemical analyses. Mechanistic studies were carried out in vitro with isolated mouse adult cardiac myocytes and fibroblasts. Results We showed that chronic Ang II infusion caused cardiac hypertrophy and fibrosis, which were all significantly attenuated by systemic administration of vinpocetine. In isolated adult mouse cardiomyocytes, vinpocetine suppressed Ang II-stimulated myocyte hypertrophic growth. In cultured cardiac fibroblasts, vinpocetine suppressed TGFβ-induced fibroblast activation and matrix gene expression, consistent with its effect in attenuating cardiac fibrosis. The effects of vinpocetine on cardiac myocyte hypertrophy and fibroblast activation are likely mediated by targeting cyclic nucleotide phosphodiesterase 1 (PDE1). Conclusions Our results reveal a novel protective effect of vinpocetine in attenuating pathological cardiac remodeling through suppressing cardiac myocyte hypertrophic growth and fibroblast activation and fibrotic gene expression. These studies may also shed light on developing novel therapeutic agents for antagonizing pathological cardiac remodeling. PMID:28321644
Wu, Mei-Ping; Zhang, Yi-Shuai; Xu, Xiangbin; Zhou, Qian; Li, Jian-Dong; Yan, Chen
2017-04-01
Pathological cardiac remodeling, characterized by cardiac hypertrophy and fibrosis, is a pathological feature of many cardiac disorders that leads to heart failure and cardiac arrest. Vinpocetine, a derivative of the alkaloid vincamine, has been used for enhancing cerebral blood flow to treat cognitive impairment. However, its role in pathological cardiac remodeling remains unknown. The aim of this study is to examine the effect of vinpocetine on pathological cardiac remodeling induced by chronic stimulation with angiotensin II (Ang II). Mice received Ang II infusion via osmotic pumps in the presence of vehicle or vinpocetine. Cardiac hypertrophy and fibrosis were assessed by morphological, histological, and biochemical analyses. Mechanistic studies were carried out in vitro with isolated mouse adult cardiac myocytes and fibroblasts. We showed that chronic Ang II infusion caused cardiac hypertrophy and fibrosis, which were all significantly attenuated by systemic administration of vinpocetine. In isolated adult mouse cardiomyocytes, vinpocetine suppressed Ang II-stimulated myocyte hypertrophic growth. In cultured cardiac fibroblasts, vinpocetine suppressed TGFβ-induced fibroblast activation and matrix gene expression, consistent with its effect in attenuating cardiac fibrosis. The effects of vinpocetine on cardiac myocyte hypertrophy and fibroblast activation are likely mediated by targeting cyclic nucleotide phosphodiesterase 1 (PDE1). Our results reveal a novel protective effect of vinpocetine in attenuating pathological cardiac remodeling through suppressing cardiac myocyte hypertrophic growth and fibroblast activation and fibrotic gene expression. These studies may also shed light on developing novel therapeutic agents for antagonizing pathological cardiac remodeling.
Ali, Shayesta; Sofi, Khalid; Dar, Abdul Qayoom
2017-01-01
Background: Pain is a common complaint after surgery and seems to be difficult to manage in children because of fear of complications of pain treatment or misconception that infants and small children do not feel pain at all or feel less pain. A survey reported that 40% of pediatric surgical patients experienced moderate or severe postoperative pain and that more than 75% had insufficient analgesia. Our study was carried to provide continuous infusion of intravenous (i.v.) tramadol alone using a dedicated infusion device Graseby 2100 syringe pump and compared it to a combination of i.v. tramadol infusion and per rectal paracetamol. Subjects and Methods: A total of 124 children aged 1–8 years selected for the study were randomized into two groups using a table of random numbers. Power calculation had suggested a sample size of 62 in each group with a power of 80% and significance level of 5%. Group A comprising 62 children, received i.v. infusion of tramadol in a dose of 0.25 mg/kg/h for 24 h postoperatively. Group B comprising 62 children, received i.v. infusion of tramadol in a dose of 0.25 mg/kg/h for 24 h postoperatively in addition to per rectal suppository of paracetamol in a dose of 90 mg/kg in 24 h (30 mg/kg as first dose followed by 20 mg/kg every 6 hourly for the next 18 h). Postoperatively, patients were observed for 24 h. Results: A statistically significant difference (P ≤ 0.001) in Face, Legs, Activity, Cry, Consolability pain scores was seen between two groups at 4, 6, and 8 h. Pain scores being less in Group B patients who had received infusion of tramadol and per rectal suppositories of paracetamol compared to Group A patients who received only infusion of tramadol. A statistically significant difference (P < 0.05) was found in mean analgesic consumption during the first 24 h between the groups. Consumption was more in Group A as compared to Group B. In Group A, 13 patients (21%) required rescue analgesia as compared to only 4 patients (6.5%) in Group B. Conclusion: We recommend use of an infusion of tramadol in a dose of 0.25 mg/kg/h in the first 24 h after surgery, in combination with a regular per rectal paracetamol in a daily dose of 90 mg/kg/day in four divided doses for children after major abdominal surgery. However, a close nursing supervision is essential to increase the safety profile. PMID:28663644
Liu, Xiaobing; Zheng, O'Neill; Niu, Fuxin
2016-01-01
Most commercial ground source heat pump systems (GSHP) in the United States are in a distributed configuration. These systems circulate water or an anti-freeze solution through multiple heat pump units via a central pumping system, which usually uses variable speed pump(s). Variable speed pumps have potential to significantly reduce pumping energy use; however, the energy savings in reality could be far away from its potential due to improper pumping system design and controls. In this paper, a simplified hydronic pumping system was simulated with the dynamic Modelica models to evaluate three different pumping control strategies. This includes two conventional controlmore » strategies, which are to maintain a constant differential pressure across either the supply and return mains, or at the most hydraulically remote heat pump; and an innovative control strategy, which adjusts system flow rate based on the demand of each heat pump. The simulation results indicate that a significant overflow occurs at part load conditions when the variable speed pump is controlled to main a constant differential pressure across the supply and return mains of the piping system. On the other hand, an underflow occurs at part load conditions when the variable speed pump is controlled to maintain a constant differential pressure across the furthest heat pump. The flow-demand-based control can provide needed flow rate to each heat pump at any given time, and with less pumping energy use than the two conventional controls. Finally, a typical distributed GSHP system was studied to evaluate the energy saving potential of applying the flow-demand-based pumping control strategy. This case study shows that the annual pumping energy consumption can be reduced by 62% using the flow-demand-based control compared with that using the conventional pressure-based control to maintain a constant differential pressure a cross the supply and return mains.« less
2013-02-06
The Intraoperative Effect of Dexmedetomidine on Cisatracurium Infusion Consumption and Its Recovery Index.; Effect of Dexmedetomidine on Sufentanil Consumption.; Quantitative Analysis of Cisatracurium Infusion Requirements, Sufentanil Consumption and Recovery Index in Different Age Groups.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xiaobing; Zheng, O'Neill; Niu, Fuxin
Most commercial ground source heat pump systems (GSHP) in the United States are in a distributed configuration. These systems circulate water or an anti-freeze solution through multiple heat pump units via a central pumping system, which usually uses variable speed pump(s). Variable speed pumps have potential to significantly reduce pumping energy use; however, the energy savings in reality could be far away from its potential due to improper pumping system design and controls. In this paper, a simplified hydronic pumping system was simulated with the dynamic Modelica models to evaluate three different pumping control strategies. This includes two conventional controlmore » strategies, which are to maintain a constant differential pressure across either the supply and return mains, or at the most hydraulically remote heat pump; and an innovative control strategy, which adjusts system flow rate based on the demand of each heat pump. The simulation results indicate that a significant overflow occurs at part load conditions when the variable speed pump is controlled to main a constant differential pressure across the supply and return mains of the piping system. On the other hand, an underflow occurs at part load conditions when the variable speed pump is controlled to maintain a constant differential pressure across the furthest heat pump. The flow-demand-based control can provide needed flow rate to each heat pump at any given time, and with less pumping energy use than the two conventional controls. Finally, a typical distributed GSHP system was studied to evaluate the energy saving potential of applying the flow-demand-based pumping control strategy. This case study shows that the annual pumping energy consumption can be reduced by 62% using the flow-demand-based control compared with that using the conventional pressure-based control to maintain a constant differential pressure a cross the supply and return mains.« less
Nielsen, Signe Tellerup; Lehrskov-Schmidt, Louise; Krogh-Madsen, Rikke; Solomon, Thomas P J; Lehrskov-Schmidt, Lars; Holst, Jens Juul; Møller, Kirsten
2013-11-01
Type 2 diabetes mellitus (T2DM) is associated with peripheral insulin resistance, impaired incretin effect, and increased plasma levels of tumour necrosis factor-alpha (TNF-α). Although TNF-α infusion at a dose that induces systemic inflammation in healthy volunteers has been demonstrated to induce peripheral insulin resistance, the influence of this cytokine on the incretin effect is unknown. We investigated whether systemic inflammation induced by TNF-α infusion in healthy volunteers alters the incretin hormone response to oral and intravenous glucose loads in a crossover study design with ten healthy male volunteers (mean age 24 years, mean body mass index 23.7 kg/m(2) ). The study consisted of four study days: days 1 and 2, 6-h infusion of saline; days 3 and 4, 6-h infusion of TNF-α; days 1 and 3, 4-h oral glucose tolerance test; and days 2 and 4, 4-h corresponding intravenous isoglycaemic glucose tolerance test. Glucose tolerance tests were initiated after 2 h of saline/TNF-α infusion. Plasma concentrations of TNF-α, interleukin 6, glucose, incretin hormones, and cortisol, and serum concentrations of C-peptide and insulin were measured throughout the study days. Insulin sensitivity was estimated by the Matsuda index and homeostasis model assessment of insulin resistance (HOMA-IR). Prehepatic insulin secretion rates were calculated. TNF-α infusion induced symptoms of systemic inflammation; increased plasma levels of cortisol, TNF-α, and interleukin 6; and increased the HOMA-IR. The secretion of incretin hormones as well as the incretin effect remained unchanged. In healthy young male volunteers, acute systemic inflammation induced by infusion of TNF-α is associated with insulin resistance with no change in the incretin effect. Copyright © 2013 John Wiley & Sons, Ltd.
Use of cryopumps on large space simulation systems
NASA Technical Reports Server (NTRS)
Mccrary, L. E.
1980-01-01
The need for clean, oil free space simulation systems has demanded the development of large, clean pumping systems. The assurance of optically dense liquid nitrogen baffles over diffusion pumps prevents backstreaming to a large extent, but does not preclude contamination from accidents or a control failure. Turbomolecular pumps or ion pumps achieve oil free systems but are only practical for relatively small chambers. Large cryopumps were developed and checked out which do achieve clean pumping of very large chambers. These pumps can be used as the original pumping system or can be retrofitted as a replacement for existing diffusion pumps.
The apéritif effect: alcohol's effects on the brain's response to food aromas in women
Eiler, William J.A.; Džemidžić, Mario; Case, K. Rose; Soeurt, Christina M.; Armstrong, Cheryl L.H.; Mattes, Richard D.; O'Connor, Sean J.; Harezlak, Jaroslaw; Acton, Anthony J.; Considine, Robert V.; Kareken, David A.
2015-01-01
Objective Consuming alcohol prior to a meal (an apéritif) increases food consumption. This greater food consumption may result from increased activity in brain regions that mediate reward and regulate feeding behavior. Using functional magnetic resonance imaging, we evaluated the blood oxygenation level dependent (BOLD) response to the food aromas of either roast beef or Italian meat sauce following pharmacokinetically controlled intravenous infusion of alcohol. Methods BOLD activation to food aromas in non-obese women (n=35) was evaluated once during intravenous infusion of 6% v/v EtOH, clamped at a steady-state breath alcohol concentration of 50 mg/dL, and once during infusion of saline using matching pump rates. Ad libitum intake of roast beef with noodles or Italian meat sauce with pasta following imaging was recorded. Results BOLD activation to food relative to non-food odors in the hypothalamic area was increased during alcohol pre-load when compared to saline. Food consumption was significantly greater, and levels of ghrelin were reduced, following alcohol. Conclusions An alcohol pre-load increased food consumption and potentiated differences between food and non-food BOLD responses in the region of the hypothalamus. The hypothalamus may mediate the interplay of alcohol and responses to food cues, thus playing a role in the apéritif phenomenon. PMID:26110891
Water, electrolytes, vitamins and trace elements – Guidelines on Parenteral Nutrition, Chapter 7
Biesalski, H. K.; Bischoff, S. C.; Boehles, H. J.; Muehlhoefer, A.
2009-01-01
A close cooperation between medical teams is necessary when calculating the fluid intake of parenterally fed patients. Fluids supplied parenterally, orally and enterally, other infusions, and additional fluid losses (e.g. diarrhea) must be considered. Targeted diagnostic monitoring (volume status) is required in patients with disturbed water or electrolyte balance. Fluid requirements of adults with normal hydration status is approximately 30–40 ml/kg body weight/d, but fluid needs usually increase during fever. Serum electrolyte concentrations should be determined prior to PN, and patients with normal fluid and electrolyte balance should receive intakes follwing standard recommendations with PN. Additional requirements should usually be administered via separate infusion pumps. Concentrated potassium (1 mval/ml) or 20% NaCl solutions should be infused via a central venous catheter. Electrolyte intake should be adjusted according to the results of regular laboratory analyses. Individual determination of electrolyte intake is required when electrolyte balance is initially altered (e.g. due to chronic diarrhea, recurring vomiting, renal insufficiency etc.). Vitamins and trace elements should be generally substituted in PN, unless there are contraindications. The supplementation of vitamins and trace elements is obligatory after a PN of >1 week. A standard dosage of vitamins and trace elements based on current dietary reference intakes for oral feeding is generally recommended unless certain clinical situations require other intakes. PMID:20049067
Autonomous stimulus triggered self-healing in smart structural composites
NASA Astrophysics Data System (ADS)
Norris, C. J.; White, J. A. P.; McCombe, G.; Chatterjee, P.; Bond, I. P.; Trask, R. S.
2012-09-01
Inspired by the ability of biological systems to sense and autonomously heal damage, this research has successfully demonstrated the first autonomous, stimulus triggered, self-healing system in a structural composite material. Both the sensing and healing mechanisms are reliant on microvascular channels incorporated within a laminated composite material. For the triggering mechanism, a single air filled vessel was pressurized, sealed and monitored. Upon drop weight impact (10 J), delamination and microcrack connectivity between the pressurized vessel and those open to ambient led to a pressure loss which, with the use of a suitable sensor, triggered a pump to deliver a healing agent to the damage zone. Using this autonomous healing approach, near full recovery of post-impact compression strength was achieved (94% on average). A simplified alternative system with healing agent continuously flowing through the vessels, akin to blood flow, was found to offer 100% recovery of the material’s virgin strength. Optical microscopy and ultrasonic C-scanning provided further evidence of large-scale infusion of matrix damage with the healing agent. The successful implementation of this bioinspired technology could substantially enhance the integrity and reliability of aerospace structures, whilst offering benefits through improved performance/weight ratios and extended lifetimes.
Asset tracking: what it is and whether it's right for you.
2006-10-01
This Guidance Article examines asset tracking technology, reviewing what it is, how it works, and how it can be applied in the healthcare setting to help hospitals better manage medical equipment. The article also offers guidance to help healthcare facilities determine whether (or when) they should consider investing in asset tracking technology. Asset tracking refers to the ability to detect, identify, and locate assets-infusion pumps, wheelchairs, or just about any other object or device--at any time, as well as to record the physical locations of those assets over time. Though already commonplace in some industries, tracking technology is still relatively new to healthcare. As a result, the systems, the companies that supply them, and even the applications for which they can be used are still evolving. While some healthcare facilities could see almost immediate benefits from implementing an asset tracking system now, others would benefit from waiting a little while for the marketplace to develop further. This article provides information to help hospitals determine which option will be best for them. For facilities that choose to start the system selection process now, we outline factors that should be considered.
Therapeutics of diabetes mellitus: focus on insulin analogues and insulin pumps.
Valla, Vasiliki
2010-01-01
Inadequately controlled diabetes accounts for chronic complications and increases mortality. Its therapeutic management aims in normal HbA1C, prandial and postprandial glucose levels. This review discusses diabetes management focusing on the latest insulin analogues, alternative insulin delivery systems and the artificial pancreas. Intensive insulin therapy with multiple daily injections (MDI) allows better imitation of the physiological rhythm of insulin secretion. Longer-acting, basal insulin analogues provide concomitant improvements in safety, efficacy and variability of glycaemic control, followed by low risks of hypoglycaemia. Continuous subcutaneous insulin infusion (CSII) provides long-term glycaemic control especially in type 1 diabetic patients, while reducing hypoglycaemic episodes and glycaemic variability. Continuous subcutaneous glucose monitoring (CGM) systems provide information on postprandial glucose excursions and nocturnal hypo- and/or hyperglycemias. This information enhances treatment options, provides a useful tool for self-monitoring and allows safer achievement of treatment targets. In the absence of a cure-like pancreas or islets transplants, artificial "closed-loop" systems mimicking the pancreatic activity have been also developed. Individualized treatment plans for insulin initiation and administration mode are critical in achieving target glycaemic levels. Progress in these fields is expected to facilitate and improve the quality of life of diabetic patients.
Miao, Jia; Nan, Feng; Shen, Qi; Qin, Yong-Ping; Wang, Ying; Yu, Qin; Zheng, Li; Liang, Mao-Zhi
2013-03-01
To study the pharmacokinetics of amoxicillin sodium clavulanate potassium (10:1) injection with different single doses intravenous infusion and one dose repeated intravenous injection in healthy volunteers for guiding the rational clinical regimen. Using infusion pump constantly intravenous dripping in 30 min, 4 mL blood samples were collected before and after the administration at 10 min, 20 min, 30 min, 45 min, and 1, 1.25, 1.5, 2, 2.5, 3, 4, 6, 8, 10 h. The plasma concentrations of amoxicillin and clavulanate were detected by high performance liquid chromatography- mass spectrometry/mass spectrometry method. The pharmacokinetic parameters were calculated by DAS2.0.1 software. The dispositions of amoxicillin and clavulanate matched three or two compartment model with the weight coefficient 1/cc. To avoid the biases caused by compartment model fitting, the pharmacokinetic parameters were statistical moment parameters of non-compartment model. The peak concentrations, the areas under curve, the half-lifes and the clearances after single injections of 0. 55 g, 1.1 g and 2.2 g indicated that both amoxillin and clavulanate had linear dynamics characteristics. After 1.1 g single dose and multiple doses infusion, the pharmacokinetic parameters of amoxicillin and clavulanate were close respectively, and the trough concentrations before the 7th to 13th administration were lower than the detection limitation, which implied that the previous administration had cleared out before the next administration, and no accumulation happened after multiple doses. The amoxicillin sodium clavulanate potassium (10:1) injection possesses the linear kinetics. The dosage regimen of 1.1 g Q8h intravenous infusion could meet the needs of clinical therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Su, Qing; Qin, Da-Nian, E-mail: dnqin@stu.edu.cn; Wang, Fu-Xin
Aims: To explore whether reactive oxygen species (ROS) scavenger (tempol) in the hypothalamic paraventricular nucleus (PVN) attenuates renin–angiotensin system (RAS) and proinflammatory cytokines (PICs), and decreases the blood pressure and sympathetic activity in angiotensin II (ANG II)-induced hypertension. Methods and results: Male Sprague–Dawley rats were infused intravenously with ANG II (10 ng/kg per min) or normal saline (NS) for 4 weeks. These rats were treated with bilateral PVN infusion of oxygen free radical scavenger tempol (TEMP, 20 μg/h) or vehicle (artificial cerebrospinal fluid, aCSF) for 4 weeks. ANG II infusion resulted in increased mean arterial pressure (MAP) and renal sympatheticmore » nerve activity (RSNA). These ANG II-infused rats also had higher levels of gp91{sup phox} (a subunit of NAD(P)H oxidase), angiotensin-converting enzyme (ACE), and interleukin-1beta (IL-1β) in the PVN than the control animals. Treatment with PVN infusion of TEMP attenuated the overexpression of gp91{sup phox}, ACE and IL-1β within the PVN, and decreased sympathetic activity and MAP in ANG II-infused rats. Conclusion: These findings suggest that ANG II infusion induces elevated PICs and oxidative stress in the PVN, which contribute to the sympathoexcitation in hypertension. Inhibition of reactive oxygen species in hypothalamic paraventricular nucleus attenuates the renin–angiotensin system, proinflammatory cytokines and oxidative stress in ANG II-induced hypertension. - Highlights: • The effect of chronic inhibiting PVN superoxide on hypertension was investigated. • ANG II infusion induced increased proinflammatory cytokines and superoxide in PVN. • ANG II infusion resulted in oxidative stress, sympathoexcitation and hypertension. • Chronic inhibiting PVN superoxide attenuates RAS and cytokines in hypertension.« less
NASA Astrophysics Data System (ADS)
Sillay, Karl; Schomberg, Dominic; Hinchman, Angelica; Kumbier, Lauren; Ross, Chris; Kubota, Ken; Brodsky, Ethan; Miranpuri, Gurwattan
2012-04-01
Convection-enhanced delivery (CED) is an advanced infusion technique used to deliver therapeutic agents into the brain. CED has shown promise in recent clinical trials. Independent verification of published parameters is warranted with benchmark testing of published parameters in applicable models such as gel phantoms, ex vivo tissue and in vivo non-human animal models to effectively inform planned and future clinical therapies. In the current study, specific performance characteristics of two CED infusion catheter systems, such as backflow, infusion cloud morphology, volume of distribution (mm3) versus the infused volume (mm3) (Vd/Vi) ratios, rate of infusion (µl min-1) and pressure (mmHg), were examined to ensure published performance standards for the ERG valve-tip (VT) catheter. We tested the hypothesis that the ERG VT catheter with an infusion protocol of a steady 1 µl min-1 functionality is comparable to the newly FDA approved MRI Interventions Smart Flow (SF) catheter with the UCSF infusion protocol in an agarose gel model. In the gel phantom models, no significant difference was found in performance parameters between the VT and SF catheter. We report, for the first time, such benchmark characteristics in CED between these two otherwise similar single-end port VT with stylet and end-port non-stylet infusion systems. Results of the current study in agarose gel models suggest that the performance of the VT catheter is comparable to the SF catheter and warrants further investigation as a tool in the armamentarium of CED techniques for eventual clinical use and application.
Hatcher, Irene; Sullivan, Mark; Hutchinson, James; Thurman, Susan; Gaffney, F Andrew
2004-10-01
Improving medication safety at the point of care--particularly for high-risk drugs--is a major concern of nursing administrators. The medication errors most likely to cause harm are administration errors related to infusion of high-risk medications. An intravenous medication safety system is designed to prevent high-risk infusion medication errors and to capture continuous quality improvement data for best practice improvement. Initial testing with 50 systems in 2 units at Vanderbilt University Medical Center revealed that, even in the presence of a fully mature computerized prescriber order-entry system, the new safety system averted 99 potential infusion errors in 8 months.
Planetary Science Technology Infusion Study: Findings and Recommendations Status
NASA Technical Reports Server (NTRS)
Anderson, David J.; Sandifer, Carl E., II; Sarver-Verhey, Timothy R.; Vento, Daniel M.; Zakrajsek, June F.
2014-01-01
The Planetary Science Division (PSD) within the National Aeronautics and Space Administrations (NASA) Science Mission Directorate (SMD) at NASA Headquarters sought to understand how to better realize a scientific return on spacecraft system technology investments currently being funded. In order to achieve this objective, a team at NASA Glenn Research Center was tasked with surveying the science and mission communities to collect their insight on technology infusion and additionally sought inputs from industry, universities, and other organizations involved with proposing for future PSD missions. This survey was undertaken by issuing a Request for Information (RFI) activity that requested input from the proposing community on present technology infusion efforts. The Technology Infusion Study was initiated in March 2013 with the release of the RFI request. The evaluation team compiled and assessed this input in order to provide PSD with recommendations on how to effectively infuse new spacecraft systems technologies that it develops into future competed missions enabling increased scientific discoveries, lower mission cost, or both. This team is comprised of personnel from the Radioisotope Power Systems (RPS) Program and the In-Space Propulsion Technology (ISPT) Program staff.The RFI survey covered two aspects of technology infusion: 1) General Insight, including: their assessment of barriers to technology infusion as related to infusion approach; technology readiness; information and documentation products; communication; integration considerations; interaction with technology development areas; cost-capped mission areas; risk considerations; system level impacts and implementation; and mission pull. 2) Specific technologies from the most recent PSD Announcements of Opportunities (AOs): The Advanced Stirling Radioisotope Generator (ASRG), aerocapture and aeroshell hardware technologies, the NASA Evolutionary Xenon Thruster (NEXT) ion propulsion system, and the Advanced Materials Bi-propellant Rocket (AMBR) engine.This report will present the teams Findings from the RFI inputs and the recommendations that arose from these findings. Methodologies on the findings and recommendations development are discussed.
[Complications of intrathecal baclofen therapy].
Paskhin, D L; Dekopov, A V; Tomsky, A A; Isagulyan, E D; Salova, E M
To analyze complications of intrathecal baclofen therapy and identify high-risk groups. We implanted 52 pumps to spastic patients for chronic intrathecal baclofen infusion. Two groups of patients were distinguished: 23 patients with spinal spasticity (group 1) and 29 patients with cerebral spasticity (group 2). The mean patient age was 37.2±14.6 years in group 1 and 17.3±10.3 years in group 2. Surgery was performed according to a standard procedure. A Medstream (Codman) pump was implanted in 10 cases, and a Synchromed II (Medtronic) pump was implanted in the remaining 42 cases. Complications developed in 12 (23%) patients. We divided complications into 3 groups: baclofen underdose, baclofen overdose, and others. Insufficiency of intrathecal therapy was observed in 7 cases, which was caused by catheter migration (5 cases) and pump dysfunction (2 cases). In one case, baclofen overdose was observed after air travel. Other complications included 4 cases of persistent peri-implant seroma and infectious complications. Groups with a high risk of complications were identified based on an analysis of the results. Patients with severe dystonia of the trunk muscles have an increased risk of spinal catheter migration. Pronounced communicating hydrocephalus is associated with the risk of cerebrospinal fluid leak through a catheter shaft channel. Weakness of the axial musculature can lead to progression of scoliotic deformity. In some cases, chronic intrathecal baclofen therapy can be accompanied by various complications. This technique should be carefully used in patients from high-risk groups.
Grunberger, George; Handelsman, Yehuda; Bloomgarden, Zachary T; Fonseca, Vivian A; Garber, Alan J; Haas, Richard A; Roberts, Victor L; Umpierrez, Guillermo E
2018-03-01
This document represents the official position of the American Association of Clinical Endocrinologists and American College of Endocrinology. Where there are no randomized controlled trials or specific U.S. FDA labeling for issues in clinical practice, the participating clinical experts utilized their judgment and experience. Every effort was made to achieve consensus among the committee members. Position statements are meant to provide guidance, but they are not to be considered prescriptive for any individual patient and cannot replace the judgment of a clinician. AACE/ACE Task Force on Integration of Insulin Pumps and Continuous Glucose Monitoring in the Management of Patients With Diabetes Mellitus Chair George Grunberger, MD, FACP, FACE Task Force Members Yehuda Handelsman, MD, FACP, FNLA, MACE Zachary T. Bloomgarden, MD, MACE Vivian A. Fonseca, MD, FACE Alan J. Garber, MD, PhD, FACE Richard A. Haas, MD, FACE Victor L. Roberts, MD, MBA, FACP, FACE Guillermo E. Umpierrez, MD, CDE, FACP, FACE Abbreviations: AACE = American Association of Clinical Endocrinologists ACE = American College of Endocrinology A1C = glycated hemoglobin BGM = blood glucose monitoring CGM = continuous glucose monitoring CSII = continuous subcutaneous insulin infusion DM = diabetes mellitus FDA = Food & Drug Administration MDI = multiple daily injections T1DM = type 1 diabetes mellitus T2DM = type 2 diabetes mellitus SAP = sensor-augmented pump SMBG = self-monitoring of blood glucose STAR 3 = Sensor-Augmented Pump Therapy for A1C Reduction phase 3 trial.
New technologies in the treatment of type 1 diabetes.
Schmidt, Signe
2013-11-01
Type 1 diabetes is a chronic condition characterized by insufficient production of insulin, a hormone needed for proper control of blood glucose levels. People with type 1 diabetes must monitor their blood glucose throughout the day using a glucose meter or a continuous glucose monitor, calculate how much insulin is needed to maintain normal blood glucose levels, and administer the insulin dose by pen injection or insulin pump infusion into the subcutaneous tissue. In recent years, several new technologies for the treatment of type 1 diabetes have been developed. This PhD thesis covers two studies of the effects of commercially available technologies--sensor-augmented pump therapy and automated insulin bolus calculators--when used in clinical practice. Both studies demonstrated that these technologies have the potential to improve diabetes care. In addition, two in-clinic studies related to emerging technologies--closed-loop glucose control and virtual simulation environments--are included in the thesis. The results of these experiments provided proof of concept and will serve as a basis for further research in these fields.
Clinical Alarms in intensive care: implications of alarm fatigue for the safety of patients1
Bridi, Adriana Carla; Louro, Thiago Quinellato; da Silva, Roberto Carlos Lyra
2014-01-01
OBJECTIVES: to identify the number of electro-medical pieces of equipment in a coronary care unit, characterize their types, and analyze implications for the safety of patients from the perspective of alarm fatigue. METHOD: this quantitative, observational, descriptive, non-participatory study was conducted in a coronary care unit of a cardiology hospital with 170 beds. RESULTS: a total of 426 alarms were recorded in 40 hours of observation: 227 were triggered by multi-parametric monitors and 199 were triggered by other equipment (infusion pumps, dialysis pumps, mechanical ventilators, and intra-aortic balloons); that is an average of 10.6 alarms per hour. CONCLUSION: the results reinforce the importance of properly configuring physiological variables, the volume and parameters of alarms of multi-parametric monitors within the routine of intensive care units. The alarms of equipment intended to protect patients have increased noise within the unit, the level of distraction and interruptions in the workflow, leading to a false sense of security. PMID:25591100
Wiley, Michael R; Durham, Timothy B; Adams, Lisa A; Chambers, Mark G; Lin, Chaohua; Liu, Chin; Marimuthu, Jothirajah; Mitchell, Peter G; Mudra, Daniel R; Swearingen, Craig A; Toth, James L; Weller, Jennifer M; Thirunavukkarasu, Kannan
2016-06-23
The development of reliable relationships between in vivo target engagement, pharmacodynamic activity, and efficacy in chronic disease models is beneficial for enabling hypothesis-driven drug discovery and facilitating the development of patient-focused candidate selection criteria. Toward those ends, osmotic infusion pumps can be useful for overcoming limitations in the PK properties of proof-of-concept (POC) compounds to accelerate the development of such relationships. In this report, we describe the application of this strategy to the development of hydantoin-derived aggrecanase inhibitors (eg, 3) for the treatment of osteoarthiritis (OA). Potent, selective inhibitors were efficacious in both chemical and surgical models of OA when exposures were sustained in excess of 10 times the plasma IC50. The use of these data for establishing patient-focused candidate selection criteria is exemplified with the characterization of compound 8, which is projected to sustain the desired level of target engagement at a dose of 45 mg qd.
Yeh, Hsin-Chieh; Brown, Todd T; Maruthur, Nisa; Ranasinghe, Padmini; Berger, Zackary; Suh, Yong D; Wilson, Lisa M; Haberl, Elisabeth B; Brick, Jessica; Bass, Eric B; Golden, Sherita Hill
2012-09-04
Patients with diabetes mellitus need information about the effectiveness of innovations in insulin delivery and glucose monitoring. To review how intensive insulin therapy (multiple daily injections [MDI] vs. rapid-acting analogue-based continuous subcutaneous insulin infusion [CSII]) or method of monitoring (self-monitoring of blood glucose [SMBG] vs. real-time continuous glucose monitoring [rt-CGM]) affects outcomes in types 1 and 2 diabetes mellitus. MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials through February 2012 without language restrictions. 33 randomized, controlled trials in children or adults that compared CSII with MDI (n=19), rt-CGM with SMBG (n=10), or sensor-augmented insulin pump use with MDI and SMBG (n=4). 2 reviewers independently evaluated studies for eligibility and quality and serially abstracted data. In randomized, controlled trials, MDI and CSII showed similar effects on hemoglobin A1c (HbA1c) levels and severe hypoglycemia in children or adults with type 1 diabetes mellitus and adults with type 2 diabetes mellitus. In adults with type 1 diabetes mellitus, HbA1c levels decreased more with CSII than with MDI, but 1 study heavily influenced these results. Compared with SMBG, rt-CGM achieved a lower HbA1c level (between-group difference of change, 0.26% [95% CI, 0.33% to 0.19%]) without any difference in severe hypoglycemia. Sensor-augmented insulin pump use decreased HbA1c levels more than MDI and SMBG did in persons with type 1 diabetes mellitus (between-group difference of change, 0.68% [CI, 0.81% to 0.54%]). Little evidence was available on other outcomes. Many studies were small, of short duration, and limited to white persons with type 1 diabetes mellitus. Continuous subcutaneous insulin infusion and MDI have similar effects on glycemic control and hypoglycemia, except CSII has a favorable effect on glycemic control in adults with type 1 diabetes mellitus. For glycemic control, rt-CGM is superior to SMBG and sensor-augmented insulin pumps are superior to MDI and SMBG without increasing the risk for hypoglycemia. Agency for Healthcare Research and Quality.
A new venous infusion pathway monitoring system.
Maki, Hiromichi; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton
2007-01-01
A new infusion catheter pathway monitoring system employing linear integrated circuits and a low-power 8-bit single chip microcomputer has been developed for hospital and home use. The sensor consists of coaxial three-layer conductive tapes wrapped around the polyvinyl chloride infusion tube. The inner tape is the main electrode, which records an AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The outside tape layer is a reference electrode to monitor the AC voltage around the main electrode. The center tape layer is connected to system ground and functions as a shield. The microcomputer calculates the ratio of the induced AC voltages recorded by the main and reference electrodes and if the ratio indicates a detached infusion, alerts the nursing station, via the nurse call system or low transmitting power mobile phone.
Mean Line Pump Flow Model in Rocket Engine System Simulation
NASA Technical Reports Server (NTRS)
Veres, Joseph P.; Lavelle, Thomas M.
2000-01-01
A mean line pump flow modeling method has been developed to provide a fast capability for modeling turbopumps of rocket engines. Based on this method, a mean line pump flow code PUMPA has been written that can predict the performance of pumps at off-design operating conditions, given the loss of the diffusion system at the design point. The pump code can model axial flow inducers, mixed-flow and centrifugal pumps. The code can model multistage pumps in series. The code features rapid input setup and computer run time, and is an effective analysis and conceptual design tool. The map generation capability of the code provides the map information needed for interfacing with a rocket engine system modeling code. The off-design and multistage modeling capabilities of the code permit parametric design space exploration of candidate pump configurations and provide pump performance data for engine system evaluation. The PUMPA code has been integrated with the Numerical Propulsion System Simulation (NPSS) code and an expander rocket engine system has been simulated. The mean line pump flow code runs as an integral part of the NPSS rocket engine system simulation and provides key pump performance information directly to the system model at all operating conditions.
León-Vargas, Fabian; Calm, Remei; Bondia, Jorge; Vehí, Josep
2012-01-01
Objective Set-inversion-based prandial insulin delivery is a new model-based bolus advisor for postprandial glucose control in type 1 diabetes mellitus (T1DM). It automatically coordinates the values of basal–bolus insulin to be infused during the postprandial period so as to achieve some predefined control objectives. However, the method requires an excessive computation time to compute the solution set of feasible insulin profiles, which impedes its integration into an insulin pump. In this work, a new algorithm is presented, which reduces computation time significantly and enables the integration of this new bolus advisor into current processing features of smart insulin pumps. Methods A new strategy was implemented that focused on finding the combined basal–bolus solution of interest rather than an extensive search of the feasible set of solutions. Analysis of interval simulations, inclusion of physiological assumptions, and search domain contractions were used. Data from six real patients with T1DM were used to compare the performance between the optimized and the conventional computations. Results In all cases, the optimized version yielded the basal–bolus combination recommended by the conventional method and in only 0.032% of the computation time. Simulations show that the mean number of iterations for the optimized computation requires approximately 3.59 s at 20 MHz processing power, in line with current features of smart pumps. Conclusions A computationally efficient method for basal–bolus coordination in postprandial glucose control has been presented and tested. The results indicate that an embedded algorithm within smart insulin pumps is now feasible. Nonetheless, we acknowledge that a clinical trial will be needed in order to justify this claim. PMID:23294789
Kassis, Timothy; Yarlagadda, Sri Charan; Kohan, Alison B.; Tso, Patrick; Breedveld, Victor
2016-01-01
Dietary lipids are transported from the intestine through contractile lymphatics. Chronic lipid loads can adversely affect lymphatic function. However, the acute lymphatic pump response in the mesentery to a postprandial lipid meal has gone unexplored. In this study, we used the rat mesenteric collecting vessel as an in vivo model to quantify the effect of lipoproteins on vessel function. Lipid load was continuously monitored by using the intensity of a fluorescent fatty-acid analog, which we infused along with a fat emulsion through a duodenal cannula. The vessel contractility was simultaneously quantified. We demonstrated for the first time that collecting lymphatic vessels respond to an acute lipid load by reducing pump function. High lipid levels decreased contraction frequency and amplitude. We also showed a strong tonic response through a reduction in the end-diastolic and systolic diameters. We further characterized the changes in flow rate and viscosity and showed that both increase postprandially. In addition, shear-mediated Ca2+ signaling in lymphatic endothelial cells differed when cultured with lipoproteins. Together these results show that the in vivo response could be both shear and lipid mediated and provide the first evidence that high postprandial lipid has an immediate negative effect on lymphatic function even in the acute setting. PMID:26968208
Turley, James P; Johnson, Todd R; Smith, Danielle Paige; Zhang, Jaijie; Brixey, Juliana J
2006-04-01
Use of medical devices often directly contributes to medical errors. Because it is difficult or impossible to change the design of existing devices, the best opportunity for improving medical device safety is during the purchasing process. However, most hospital personnel are not familiar with the usability evaluation methods designed to identify aspects of a user interface that do not support intuitive and safe use. A review of medical device operating manuals is proposed as a more practical method of usability evaluation. Operating manuals for five volumetric infusion pumps from three manufacturers were selected for this study (January-April 2003). Each manual's safety message content was evaluated to determine whether the message indicated a device design characteristic that violated known usability principles (heuristics) or indicated a violation of an affordance of the device. "Minimize memory load," with 65 violations, was the heuristic violated most frequently across pumps. Variations between pumps, including the frequency and severity of violations for each, were noted. Results suggest that manual review can provide a proxy for heuristic evaluation of the actual medical device. This method, intended to be a component of prepurchasing evaluation, can complement more formal usability evaluation methods and be used to select a subset of devices for more extensive and formal testing.
Alvarez, J; Baluja, A; Selas, S; Otero, P; Rial, M; Veiras, S; Caruezo, V; Taboada, M; Rodriguez, I; Castroagudin, J; Tome, S; Rodriguez, A; Rodriguez, J
2013-11-01
Liver dysfunction due to a low cardiac output state after cardiac surgery is associated with a poor prognosis, but whether one inotrope is superior to another in improving hepatic perfusion remains uncertain. This study compared the systemic and hepatic haemodynamic effects of levosimendan to dobutamine in patients with a low cardiac output state (cardiac index < 2.2 l/min/m2) after on-pump cardiac surgery. A total of 25 patients were randomised to receive either an intravenous bolus of levosimendan (12 µg/kg) over 15 minutes, followed by an infusion of 0.2 µg/kg/min for 24 hours, or an infusion of dobutamine 7.5 µg/kg/min for 24 hours and completed the study. The systemic and hepatic haemodynamics at 24 and 48 hours were all better after levosimendan than dobutamine (dobutamine group: cardiac index (l/min/m2)=2.51 [standard deviation ±0.29], 2.40±0.23; portal vein flow (ml/min): 614.0±124.7, 585.9±144.8; pulsatility index: 2.02±0,28, 2.98±0.27 versus the levosimendan group: cardiac index: 3.02± 0.27, 2.98± 0.30; portal vein flow: 723.0± 143.5, 702.9±117.8; pulsatility index: 1.71±0.26, 1.73±0.27). The improvement in portal vein blood flow at 48 hours was significantly better after levosimendan than dobutamine (41% vs. 11% increment from baseline, P<0.05). In addition, there was a significant reduction in hepatic artery resistance after levosimendan but not dobutamine (resistance index reduction 6.5% vs. 0%, P<0.05). In summary, levosimendan can be considered as a selective liver vasodilator and can improve hepatic blood flow through both the hepatic artery and portal venous system, whereas dobutamine can only improve the portal venous blood flow without vasodilating the hepatic artery.
Determining the optimum solar water pumping system for domestic use, livestock water, or irrigation
USDA-ARS?s Scientific Manuscript database
For several years we have field tested many different types of solar powered water pumping systems. In this paper, several steps are given to select a solar-PV water pumping system. The steps for selection of stand-alone water pumping system were: deciding whether a wind or solar water pumping sys...
Chang, Min; Li, Yongchao; Angeles, Reginald; Khan, Samina; Chen, Lian; Kaplan, Julia; Yang, Liyu
2011-08-01
Two approaches to monitor the matrix effect on ionization in study samples were described. One approach is the addition of multiple reaction monitoring transitions to the bioanalytical methods to monitor the presence of known ionization modification-causing components of the matrix, for example, m/z 184→125 (or m/z 184→184) and m/z 133→89 may be used for phospholipids and polyethylene oxide containing surfactants, respectively. This approach requires no additional equipment and can be readily adapted for most method. The approach detects only the intended interfering compounds and provides little quantitative indication if the matrix effect is within the tolerable range (±15%). The other approach requires the addition of an infusion pump and identifies an appropriate surrogate of the analyte to be infused for the determination of modification on the ionization of the analyte. The second approach detects interferences in the sample regardless of the sources (i.e., dosing vehicle components, co-administrated drugs, their metabolites, phospholipids, plasticizers and endogenous components introduced due to disease stage).
Applications of aerospace technology in biology and medicine
NASA Technical Reports Server (NTRS)
Bass, B.; Beall, H. C.; Brown, J. N., Jr.; Clingman, W. H.; Eakes, R. E.; Kizakevich, P. N.; Mccartney, M.; Rouse, D. J.
1982-01-01
Utilization of National Aeronautics and Space Administration (NASA) technology in medicine is discussed. The objective is best obtained by stimulation of the introduction of new or improved commercially available medical products incorporating aerospace technology. A bipolar donor/recipient model of medical technology transfer is presented to provide a basis for the team's methodology. That methodology is designed to: (1) identify medical problems and NASA technology that, in combination, constitute opportunities for successful medical products; (2) obtain the early participation of industry in the transfer process; and (3) obtain acceptance by the medical community of new medical products based on NASA technology. Two commercial transfers were completed: the Stowaway, a lightweight wheelchair that provides mobility for the disabled and elderly in the cabin of commercial aircraft, and Micromed, a portable medication infusion pump for the reliable, continuous infusion of medications such as heparin or insulin. The marketing and manufacturing factors critical to the commercialization of the lightweight walker incorporating composite materials were studied. Progress was made in the development and commercialization of each of the 18 currently active projects.
Reducing the radiation dose from inhaled americium-241 using continuously administered DTPA therapy.
Guilmette, R A; Muggenburg, B A
1988-02-01
Accelerating the removal of a radionuclide from the body of a contaminated individual is the only available approach to decreasing the radiation dose from such exposures. In this study, continuous infusion of a chelating agent, DTPA, was given to dogs that had inhaled a moderately soluble aerosol, 241 AmO2, not only to accelerate clearance of the radionuclide from the lung but also to prevent its deposition in liver and bone. Treatment was begun with an intravenous injection of CaDTPA 1 h after exposure, and was continued for 64 days after exposure by implanting subcutaneously osmotic pumps containing ZnDTPA at 1 day after exposure. The results showed that the infusion therapy was effective in blocking the translocation of 99.5 per cent of the 241Am that would have been deposited in liver, and 98.3 per cent of the 241Am that would have been deposited in bone. This result was significantly better than the result achieved using repeated intravenous injections of DTPA, the method of treatment in current use for actinide contamination cases.
Time-dependent analysis of dosage delivery information for patient-controlled analgesia services.
Kuo, I-Ting; Chang, Kuang-Yi; Juan, De-Fong; Hsu, Steen J; Chan, Chia-Tai; Tsou, Mei-Yung
2018-01-01
Pain relief always plays the essential part of perioperative care and an important role of medical quality improvement. Patient-controlled analgesia (PCA) is a method that allows a patient to self-administer small boluses of analgesic to relieve the subjective pain. PCA logs from the infusion pump consisted of a lot of text messages which record all events during the therapies. The dosage information can be extracted from PCA logs to provide easily understanding features. The analysis of dosage information with time has great help to figure out the variance of a patient's pain relief condition. To explore the trend of pain relief requirement, we developed a PCA dosage information generator (PCA DIG) to extract meaningful messages from PCA logs during the first 48 hours of therapies. PCA dosage information including consumption, delivery, infusion rate, and the ratio between demand and delivery is presented with corresponding values in 4 successive time frames. Time-dependent statistical analysis demonstrated the trends of analgesia requirements decreased gradually along with time. These findings are compatible with clinical observations and further provide valuable information about the strategy to customize postoperative pain management.
Osgood, Doreen B; Harrington, William F; Kenney, Elizabeth V; Harrington, J Frederick
2013-01-01
The authors have previously demonstrated that human herniated disc material contains high concentrations of free glutamate. In an experimental model, elevated epidural glutamate concentrations in the lumbar spine can cause a focal hyperesthetic state. Rats underwent epidural glutamate infusion in the lumbar spine by a miniosmotic pump over a 72-hour period. Some rats underwent coinfusion with glutamate and ionotropic glutamate antagonists. Nociception was assessed by von Frey fibers and by assessment of glutamate receptor expression in the corresponding dorsal horn of the spinal cord. The kainic acid antagonist, UBP 301, decreased epidural glutamate-based hyperesthesia in a dose dependent manner. Concordant with these findings, there was significant decrease in kainate receptor expression in the dorsal horn. The N-Methyl-4-isoxazoleproionic acid (NMDA) antagonist Norketamine also significantly diminished hyperesthesia and decreased receptor expression in the dorsal horn. Both UBP 301, the kainic acid receptor antagonist and Norketamine, an NMDA receptor antagonist, dampened epidural glutamate-based nociception. Focal epidural injections of Kainate or NMDA receptor antagonists could be effective treatments for disc herniation-based lumbar radiculopathy.
Roze, Stéphane; Smith-Palmer, Jayne; Valentine, William J; Cook, Mark; Jethwa, Manisha; de Portu, Simona; Pickup, John C
2016-01-01
Continuous subcutaneous insulin infusion (CSII) is an important treatment option for type 1 diabetes patients unable to achieve adequate glycemic control with multiple daily injections (MDI). Combining CSII with continuous glucose monitoring (CGM) in sensor-augmented pump therapy (SAP) with a low glucose-suspend (LGS) feature may further improve glycemic control and reduce the frequency of hypoglycemia. A cost-effectiveness analysis of SAP + LGS vs. CSII plus self-monitoring of blood glucose (SMBG) was performed to determine the health economic benefits of SAP + LGS in type 1 diabetes patients using CSII in the U.K. Cost-effectiveness analysis was performed using the CORE diabetes model. Treatment effects were sourced from the literature, where SAP + LGS was associated with a projected HbA1c reduction of -1.49% vs. -0.62% for CSII, and a reduced frequency of severe hypoglycemia. The time horizon was that of patient lifetimes; future costs and clinical outcomes were discounted at 3.5% and 1.5% per annum, respectively. Projected outcomes showed that SAP + LGS was associated with higher mean quality-adjusted life expectancy (17.9 vs. 14.9 quality-adjusted life years [QALYs], SAP + LGS vs. CSII), and higher life expectancy (23.8 vs. 21.9 years), but higher mean lifetime direct costs (GBP 125,559 vs. GBP 88,991), leading to an incremental cost-effectiveness ratio (ICER) of GBP 12,233 per QALY gained for SAP + LGS vs. CSII. Findings of the base-case analysis remained robust in sensitivity analyses. For UK-based type 1 diabetes patients with poor glycemic control, the use of SAP + LGS is likely to be cost-effective compared with CSII plus SMBG.
Huang, Eagle Yi-Kung; Tsui, Pi-Fen; Kuo, Tung-Tai; Tsai, Jing-Jr.; Chou, Yu-Ching; Ma, Hsin-I; Chiang, Yung-Hsiao; Chen, Yuan-Hao
2014-01-01
Aims To investigate the role of dopamine in cognitive and motor learning skill deficits after a traumatic brain injury (TBI), we investigated dopamine release and behavioral changes at a series of time points after fluid percussion injury, and explored the potential of amantadine hydrochloride as a chronic treatment to provide behavioral recovery. Materials and Methods In this study, we sequentially investigated dopamine release at the striatum and behavioral changes at 1, 2, 4, 6, and 8 weeks after fluid percussion injury. Rats subjected to 6-Pa cerebral cortical fluid percussion injury were treated by using subcutaneous infusion pumps filled with either saline (sham group) or amantadine hydrochloride, with a releasing rate of 3.6mg/kg/hour for 8 weeks. The dopamine-releasing conditions and metabolism were analyzed sequentially by fast scan cyclic voltammetry (FSCV) and high-pressure liquid chromatography (HPLC). Novel object recognition (NOR) and fixed-speed rotarod (FSRR) behavioral tests were used to determine treatment effects on cognitive and motor deficits after injury. Results Sequential dopamine-release deficits were revealed in 6-Pa-fluid-percussion cerebral cortical injured animals. The reuptake rate (tau value) of dopamine in injured animals was prolonged, but the tau value became close to the value for the control group after amantadine therapy. Cognitive and motor learning impairments were shown evidenced by the NOR and FSRR behavioral tests after injury. Chronic amantadine therapy reversed dopamine-release deficits, and behavioral impairment after fluid percussion injuries were ameliorated in the rats treated by using amantadine-pumping infusion. Conclusion Chronic treatment with amantadine hydrochloride can ameliorate dopamine-release deficits as well as cognitive and motor deficits caused by cerebral fluid-percussion injury. PMID:24497943
Blood Warming and Hemolysis: A Systematic Review With Meta-Analysis.
Poder, Thomas G; Nonkani, Wendyam G; Tsakeu Leponkouo, Élyonore
2015-07-01
The use of fluid warmers during blood transfusion is recommended to avoid inducing hypothermia and its harmful effects. Fluid warmers offered by manufacturers can reach temperatures of 43°C. However, the recommendations of national regulatory organizations do not clearly indicate the maximum heating temperature in relation to the risk of hemolysis. To fill this gap, we conducted a systematic review of the literature with meta-analysis. To match clinical practice, this review was limited to fluid warmers that used contact heating; thus, studies that used radiofrequency or microwave heating were excluded. Twenty-four observational studies were included, 17 of which were the subject of a meta-analysis. A preliminary descriptive analysis indicated that multiple factors can influence the level of hemolysis during blood heating with a liquid warmer, including blood age, anticoagulant type, duration of exposure to heat, stirring the blood during heating, and various elements of the circuit through which blood flows (eg, type of infusion pump with pressure and flow, type of microfilter, and type of tubing). Moreover, the duration between sampling and hemolysis assay was a source of heterogeneity among studies, as were the initial free hemoglobin levels in the various experiments. In general, the increase generated by each of these factors other than temperature appears to have been limited except for blood age, which is an important parameter of hemolysis, the length of exposure to heat, and, in some studies, the type of infusion pump used. Regarding the meta-analysis, at temperatures at or less than 43°C and even up to 45-46°C, it appears that blood heating is safe and causes hemolysis only in clinically negligible proportions. Copyright © 2015 Elsevier Inc. All rights reserved.
Melo, Gustavus Lemos Ribeiro; Lages, Daniel Souza; Madureira Junior, João Lopo; Pellucci, Guilherme de Paula; Pellucci, João Wagner Junqueira
2017-01-01
There is still no consensus as to the best form and dosages of use of tranexamic acid. The aim of this study was to evaluate the use of tranexamic acid in total hip arthroplasty, in order to reduce blood loss and decrease hemoglobin, taking into account different administration protocols. 42 patients submitted to total hip arthroplasty were divided into three groups. The study was prospective and randomized. Group 1 received a venous dose of tranexamic acid of 15 mg/kg, 20 min prior to bolus incision. Group 2 received an intravenous dose of 15 mg/kg bolus, 20 min before the incision, and an extra dose of 10 mg/kg by infusion pump during the duration of the surgical procedure. Patients in group 3 did not receive tranexamic acid, being the control group. Pre- and post-operative hemoglobin levels were measured and blood loss was measured 24 h after surgery using a Portovac drain. There was a significant reduction in the amount of bleeding through the Portovac drain and reduction in postoperative hemoglobin drop in patients who used tranexamic acid. There was neither significant difference in hemoglobin drop between groups 1 and 2, nor was there a need for hemotransfusion. Two patients in group 3 required blood transfusion. The findings demonstrated that the use of intravenous tranexamic acid in total hip arthroplasty reduced postoperative bleeding rates and significantly reduced serum hemoglobin without increasing thromboembolic effects. The bolus and bolus + infusion pump methods were shown to have a similar influence on hemoglobin and need for blood transfusion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ganaha, Fumikiyo; Yamada, Tetsuhisa; Yorozu, Naoya
1999-09-15
We used a vascular access system (VAS) for continuous arterial infusion (CAI) of a protease inhibitor in two patients with acute necrotizing pancreatitis. The infusion catheter was placed into the dorsal pancreatic artery in the first patient and into the gastroduodenal artery in the second, via a femoral artery approach. An implantable port was then connected to the catheter and was secured in a subcutaneous pocket prepared in the right lower abdomen. No complications related to the VAS were encountered. This system provided safe and uncontaminated vascular access for successful CAI for acute pancreatitis.
Control Law Design for Propofol Infusion to Regulate Depth of Hypnosis: A Nonlinear Control Strategy
Khaqan, Ali; Bilal, Muhammad; Ilyas, Muhammad; Ijaz, Bilal; Ali Riaz, Raja
2016-01-01
Maintaining the depth of hypnosis (DOH) during surgery is one of the major objectives of anesthesia infusion system. Continuous administration of Propofol infusion during surgical procedures is essential but increases the undue load of an anesthetist in operating room working in a multitasking setup. Manual and target controlled infusion (TCI) systems are not good at handling instabilities like blood pressure changes and heart rate variability arising due to interpatient variability. Patient safety, large interindividual variability, and less postoperative effects are the main factors to motivate automation in anesthesia. The idea of automated system for Propofol infusion excites the control engineers to come up with a more sophisticated and safe system that handles optimum delivery of drug during surgery and avoids postoperative effects. In contrast to most of the investigations with linear control strategies, the originality of this research work lies in employing a nonlinear control technique, backstepping, to track the desired hypnosis level of patients during surgery. This effort is envisioned to unleash the true capabilities of this nonlinear control technique for anesthesia systems used today in biomedical field. The working of the designed controller is studied on the real dataset of five patients undergoing surgery. The controller tracks the desired hypnosis level within the acceptable range for surgery. PMID:27293475
Khaqan, Ali; Bilal, Muhammad; Ilyas, Muhammad; Ijaz, Bilal; Ali Riaz, Raja
2015-01-01
Maintaining the depth of hypnosis (DOH) during surgery is one of the major objectives of anesthesia infusion system. Continuous administration of Propofol infusion during surgical procedures is essential but increases the undue load of an anesthetist in operating room working in a multitasking setup. Manual and target controlled infusion (TCI) systems are not good at handling instabilities like blood pressure changes and heart rate variability arising due to interpatient variability. Patient safety, large interindividual variability, and less postoperative effects are the main factors to motivate automation in anesthesia. The idea of automated system for Propofol infusion excites the control engineers to come up with a more sophisticated and safe system that handles optimum delivery of drug during surgery and avoids postoperative effects. In contrast to most of the investigations with linear control strategies, the originality of this research work lies in employing a nonlinear control technique, backstepping, to track the desired hypnosis level of patients during surgery. This effort is envisioned to unleash the true capabilities of this nonlinear control technique for anesthesia systems used today in biomedical field. The working of the designed controller is studied on the real dataset of five patients undergoing surgery. The controller tracks the desired hypnosis level within the acceptable range for surgery.
Erickson, Abbie L; Roberts, Keri; Malek, Sayeed K; Chandraker, Anil K; Tullius, Stefan G; Gabardi, Steven
2010-06-01
Antithymocyte globulin rabbit (r-ATG) has been used for the treatment and prevention of acute rejection in renal transplant recipients (RTR). Current manufacturer recommendations for r-ATG dictate the need for administration through a high-flow vein (central line). Previous studies have shown peripheral administration of r-ATG to be safe; however, these studies suggest the co-administration of heparin and hydrocortisone and did not compare the infusion-site reaction rates to a control group. A retrospective analysis was conducted of adult RTR receiving r-ATG or basiliximab between January 2004 and October 2006. Each agent was administered through a dedicated peripheral line. The primary endpoint was the incidence of infusion-site reactions. Other endpoints included the need to replace the intravenous catheter and the incidence of systemic thrombosis within 1 month of transplantation. During the study period, 152 peripheral infusions of r-ATG and 92 peripheral infusions of basiliximab were administered. No difference in infusion-site reactions was noted between the groups. There was also no difference either in the need for peripheral line replacement or the rates of systemic thrombosis. Peripheral administration of r-ATG is safe and can be infused without concomitant heparin and hydrocortisone. This method of r-ATG infusion was shown to be as safe as peripherally administered basiliximab.
Renal norepinephrine spillover during infusion of nonesterified fatty acids.
Grekin, Roger J; Ngarmukos, Chardpra-Orn; Williams, David M; Supiano, Mark A
2005-03-01
Sympathetic activity and renal norepinephrine spillover are increased in obese individuals. We have reported that infusion of nonesterified fatty acids increases blood pressure in animals through stimulation of the sympathetic nervous system. In this study, we assessed the effect of increasing circulating nonesterified fatty acids on systemic and renal norepinephrine kinetics in healthy adults by infusing fat emulsion and heparin for 4 h. (3)H-norepinephrine was infused for 60 min before and again during the last hour of the fatty acid infusion to assess norepinephrine kinetics. Renal venous blood samples were obtained to calculate renal norepinephrine spillover. Nonesterified fatty acid levels increased threefold during the first hour and remained elevated throughout the study. Arterial and renal venous plasma norepinephrine levels fell by 15% and 20%, respectively, during the infusion (P < .05 for both). Kinetic analysis indicated that systemic release of norepinephrine into an extravascular compartment decreased from 11.6 +/- 1.1 to 10.0 +/- 1.3 nmol/min/m(2) (P = .067) and renal venous norepinephrine spillover decreased from 454 +/- 54 pmol/min (P = .055). These results indicate that nonesterified fatty acids do not have a direct stimulating effect on whole-body or renal sympathetic activity. It is possible that increased plasma levels of fatty acids serve as a signal to decrease sympathetic tone during the fasting state.
Driscoll, David F; Ling, Pei-Ra; Bistrian, Bruce R
2007-01-01
The United States Pharmacopeia (USP) has proposed large-globule-size limits to ensure the physical stability of lipid injectable emulsions, expressed as the percent fat >5 microm, or PFAT(5), not exceeding 0.05%. Visibly obvious phase separation as free oil has been shown to occur in some samples if PFAT(5) is >0.4%. We recently found that lipids, newly packaged in plastic (P), exceed the proposed USP limits and seem to produce less stable total nutrient admixtures compared with those made from conventional glass (G), which do meet proposed USP standards. We tested the possible stability differences between 20% lipid injectable emulsions in either P or G in a simulated neonatal syringe infusion study. Eighteen individual syringes were prepared from each 20% lipid injectable emulsion product (n = 36) and attached to a syringe pump set at an infusion rate of 0.5 mL/hour. The starting PFAT(5) levels were measured at time 0 and after 24 hours of infusion, using a laser-based light obscuration technique as described by the USP Chapter <729>. The data were assessed by a 2-way analysis of variance (ANOVA) with Container (G vs P) and Time as the independent variables and PFAT as the dependent variable. At time 0, the starting PFAT(5) level for lipids packaged in G was 0.006% +/- 0.001% vs 0.162% +/- 0.026% for P, whereas at the end of the infusion they were 0.013% +/- 0.003% and 0.328% +/- 0.046%, respectively. Significant differences were noted overall between groups for Container, Time, and Container-Time interaction (all p < .001). Bonferroni tests showed significant differences in PFAT(5) levels between Containers at time 0 (T-0; p < .001) and T-0 vs T-24 for P-based lipids (p < .001), whereas no such differences were noted for Time for the G-based lipids. Similar results were noted for PFAT(10) levels. We confirm that presently available lipid injectable emulsions packaged in newly introduced plastic containers exceed the proposed USP <729> PFAT(5) limits and subsequently become significantly less stable during a simulated syringe-based infusion. Although modest growth (p = NS) in large-diameter fat globules was observed for the glass-based lipids, they remained within proposed USP globule size limits throughout the study. Glass-based lipids seem to be a more stable dosage form and potentially a safer way to deliver lipids via syringe infusion to critically ill neonates.
Chloral hydrate enteral infusion for sedation in ventilated children: the CHOSEN pilot study.
Joffe, Ari R; Hogan, Jessica; Sheppard, Cathy; Tawfik, Gerda; Duff, Jonathan P; Garcia Guerra, Gonzalo
2017-11-26
We aimed to test a novel method of delivery of chloral hydrate (CH) sedation in ventilated critically ill young children. Children < 12 years old, within 72 hours of admission, who were ventilated, receiving enteral tube-feeds, with intermittent CH ordered were enrolled after signed consent. Patients received a CH loading-dose of 10 mg/kg enterally, then a syringe-pump enteral infusion at 5 mg/kg/hour, increasing to a maximum of 9 mg/kg/hour. Cases were compared to historical controls matched for age group and Pediatric Risk of Mortality score (PRISM) category, using Fisher's exact test and the t test. The primary outcome was feasibility, defined as the use of an enteral CH continuous infusion without discontinuation attributable to a pre-specified potential harm. There were 21 patients enrolled, at age 11.4 (12.1) months, with bronchiolitis in 10 (48%), a mean Pediatric Logistic Organ Dysfunction (PELOD) score of 6.2 (5.2), and having received enteral CH continuous infusion for 4.5 (2.2) days. Infusion of CH was feasible in 20/21 (95%; 95% CI 76-99%) patients, with one (5%) adverse event of duodenal ulcer perforation on day 3 in a patient with croup receiving regular ibuprofen and dexamethasone. The CH infusion dose (mg/kg/h) on day 2 (n = 20) was 8.9 (IQR 5.9, 9), and on day 4 (n = 11) was 8.8 (IQR 7, 9). Days to titration of adequate sedation (defined as ≤ 3 PRN doses/shift) was 1 (IQR 0.5, 2.5), and hours to awakening for extubation was 5 (IQR 2, 9). Cases (versus controls) had less positive fluid balance at 48 h (-2 (45) vs. 26 (46) ml/kg, p = 0.051), and a decrease in number of PRN sedation doses from 12 h pre to 12 hours post starting CH (4.7 (3.3) to 2.6 (2.8), p = 0.009 versus 2.9 (3.9) to 3.4 (5), p = 0.74). There were no statistically significant differences between cases and controls in inotrope scores, signs or treatment of withdrawal, or PICU days. Delivering CH by continuous enteral infusion is feasible, effective, and may be associated with less positive fluid balance. Whether there is a risk of duodenal perforation requires further study.
A microfluidic two-pump system inspired by liquid feeding in mosquitoes
NASA Astrophysics Data System (ADS)
Marino, Andrew; Goad, Angela; Stremler, Mark; Socha, John; Jung, Sunghwan
Mosquitoes feed on nectar and blood using a two-pump system in the head-a smaller cibarial pump in line with a larger a pharyngeal pump, with a valve in between. To suck, mosquitoes transport the liquid (which may be a multi-component viscous fluid, blood) through a long micro-channel, the proboscis. In the engineering realm, microfluidic devices in biomedical applications, such as lab-on-a-chip technology, necessitate implementing a robust pump design to handle clogging and increase flow control compared to a single-pump system. In this talk, we introduce a microfluidic pump design inspired by the mosquito's two-pump system. The pumping performance (flow rate) in presence of impurities (air bubbles, soft clogs) is quantified as a function of phase difference and volume expansion of the pumps, and the elasticity of the valve.
Cerebral arterial air embolism in a child after intraosseous infusion
Knoester, H.; Maes, A.; van der Wal, A. C.; Kubat, B.
2008-01-01
Cerebral arterial air embolism (CAAE) has been reported as a rare complication of medical intervention. There has been one reported case of CAAE after the use of an intraosseous infusion (IO) system. We report on a case of CAAE after tibial IO infusion in a 7-month-old girl during resuscitation. PMID:18247071
Spaans, Floor; Melgert, Barbro N; Borghuis, Theo; Klok, Pieter A; de Vos, Paul; Bakker, Winston W; van Goor, Harry; Faas, Marijke M
2014-09-01
Changes in the systemic immune response are found in preeclampsia. This may be related to high extracellular adenosine triphosphate (ATP) levels. The question arose whether ATP could affect immune responses in pregnancy. Previously, we investigated whether ATP affected monocyte activation and subpopulations. Here, we investigated ATP-induced changes in other immune cell populations in pregnant rats, systemically and in the kidney, an affected organ in preeclampsia. Using flow cytometry or immunohistochemistry, blood and kidney leukocytes were studied in pregnant and non-pregnant rats at different intervals after ATP or saline infusion. Adenosine triphosphate (ATP) infusion induced increased peripheral blood non-classical monocytes and decreased T lymphocyte subsets in pregnant rats only, higher glomerular macrophage and T lymphocyte numbers in non-pregnant animals 1 day after infusion, and higher glomerular macrophage numbers in pregnant rats 6 days after infusion. Adenosine triphosphate (ATP) infusion in pregnant rats induced a pregnancy-specific inflammatory response. Increased ATP levels could potentially contribute to development of the inflammatory response of preeclampsia. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Development Specification for the Portable Life Support System (PLSS) Thermal Loop Pump
NASA Technical Reports Server (NTRS)
Anchondo, Ian; Campbell, Colin
2017-01-01
The AEMU Thermal Loop Pump Development Specification establishes the requirements for design, performance, and testing of the Water Pump as part of the Thermal System of the Advanced Portable Life Support System (PLSS). It is envisioned that the Thermal Loop Pump is a positive displacement pump that provides a repeatable volume of flow against a given range of back-pressures provided by the various applications. The intention is to operate the pump at a fixed speed for the given application. The primary system is made up of two identical and redundant pumps of which only one is in operation at given time. The Auxiliary Loop Pump is an identical pump design to the primary pumps but is operated at half the flow rate. Inlet positive pressure to the pumps is provided by the upstream Flexible Supply Assembly (FSA-431 and FSA-531) which are physically located inside the suit volume and pressurized by suit pressure. An integrated relief valve, placed in parallel to the pump's inlet and outlet protects the pump and loop from over-pressurization. An integrated course filter is placed upstream of the pump's inlet to provide filtration and prevent potential debris from damaging the pump.
Osmotic Drug Delivery System as a Part of Modified Release Dosage Form
Keraliya, Rajesh A.; Patel, Chirag; Patel, Pranav; Keraliya, Vipul; Soni, Tejal G.; Patel, Rajnikant C.; Patel, M. M.
2012-01-01
Conventional drug delivery systems are known to provide an immediate release of drug, in which one can not control the release of the drug and can not maintain effective concentration at the target site for longer time. Controlled drug delivery systems offer spatial control over the drug release. Osmotic pumps are most promising systems for controlled drug delivery. These systems are used for both oral administration and implantation. Osmotic pumps consist of an inner core containing drug and osmogens, coated with a semipermeable membrane. As the core absorbs water, it expands in volume, which pushes the drug solution out through the delivery ports. Osmotic pumps release drug at a rate that is independent of the pH and hydrodynamics of the dissolution medium. The historical development of osmotic systems includes development of the Rose-Nelson pump, the Higuchi-Leeper pumps, the Alzet and Osmet systems, the elementary osmotic pump, and the push-pull system. Recent advances include development of the controlled porosity osmotic pump, and systems based on asymmetric membranes. This paper highlights the principle of osmosis, materials used for fabrication of pumps, types of pumps, advantages, disadvantages, and marketed products of this system. PMID:22852100
da Silva, Alexandre A.; do Carmo, Jussara M.; Freeman, J. Nathan; Tallam, Lakshmi S.; Hall, John E.
2009-01-01
OBJECTIVE We recently showed that leptin has powerful central nervous system (CNS)-mediated antidiabetic and cardiovascular actions. This study tested whether the CNS melanocortin system mediates these actions of leptin in diabetic rats. RESEARCH DESIGN AND METHODS A cannula was placed in the lateral ventricle of Sprague-Dawley rats for intracerebroventricular infusions, and arterial and venous catheters were implanted to measure mean arterial pressure (MAP) and heart rate 24 h/day and for intravenous infusions. After recovery from surgery for 8 days, rats were injected with streptozotocin (STZ), and 5 days later, either saline or the melanocortin 3 and 4 receptor (MC3/4R) antagonist SHU-9119 (1 nmol/h) was infused intracerebroventricularly for 17 days. Seven days after starting the antagonist, leptin (0.62 μg/h) was added to the intracerebroventricular infusion for 10 days. Another group of diabetic rats was infused with the MC3/4R agonist MTII (10 ng/h i.c.v.) for 12 days, followed by 7 days at 50 ng/h. RESULTS Induction of diabetes caused hyperphagia, hyperglycemia, and decreases in heart rate (−76 bpm) and MAP (−7 mmHg). Leptin restored appetite, blood glucose, heart rate, and MAP back to pre-diabetic values in vehicle-treated rats, whereas it had no effect in SHU-9119–treated rats. MTII infusions transiently reduced blood glucose and raised heart rate and MAP, which returned to diabetic values 5–7 days after starting the infusion. CONCLUSIONS Although a functional melanocortin system is necessary for the CNS-mediated antidiabetic and cardiovascular actions of leptin, chronic MC3/4R activation is apparently not sufficient to mimic these actions of leptin that may involve interactions of multiple pathways. PMID:19491210
Methylene Blue to Treat Protamine-induced Anaphylaxis Reactions. An Experimental Study in Pigs.
Albuquerque, Agnes Afrodite S; Margarido, Edson A; Menardi, Antonio Carlos; Scorzoni, Adilson; Celotto, Andrea Carla; Rodrigues, Alfredo J; Vicente, Walter Vilella A; Evora, Paulo Roberto B
2016-01-01
To examine if methylene blue (MB) can counteract or prevent protamine (P) cardiovascular effects. The protocol included five heparinized pig groups: Group Sham -without any drug; Group MB - MB 3 mg/kg infusion; Group P - protamine; Group P/MB - MB after protamine; Group MB/P - MB before protamine. Nitric oxide levels were obtained by the nitric oxide/ozone chemiluminescence method, performed using the Nitric Oxide Analizer 280i (Sievers, Boulder, CO, USA). Malondialdehyde plasma levels were estimated using the thiobarbiturate technique. 1) Groups Sham and MB presented unchanged parameters; 2) Group P - a) Intravenous protamine infusion caused mean arterial pressure decrease and recovery trend after 25-30 minutes, b) Cardiac output decreased and remained stable until the end of protamine injection, and c) Sustained systemic vascular resistance increased until the end of protamine injection; 3) Methylene blue infusion after protamine (Group P/MB) - a) Marked mean arterial pressure decreased after protamine, but recovery after methylene blue injection, b) Cardiac output decreased after protamine infusion, recovering after methylene blue infusion, and c) Sustained systemic vascular resistance increased after protamine infusion and methylene blue injections; 4) Methylene blue infusion before protamine (Group MB/P) - a) Mean arterial pressure decrease was less severe with rapid recovery, b) After methylene blue, there was a progressive cardiac output increase up to protamine injection, when cardiac output decreased, and c) Sustained systemic vascular resistance decreased after protamine, followed by immediate Sustained systemic vascular resistance increase; 5) Plasma nitrite/nitrate and malondialdehyde values did not differ among the experimental groups. Reviewing these experimental results and our clinical experience, we suggest methylene blue safely prevents and treats hemodynamic protamine complications, from the endothelium function point of view.
[Research and application of microcontroller system for target controlled infusion].
Cheng, Yuke; Dou, Jianhong; Zhang, Xingan; Wang, Ruosong
2005-08-01
This paper presents a microcontroller system for target controlled infusion according to pharmacodynamic parameters of intravenous anesthetics. It can control the depth of anesthesia by adjusting the level of plasma concentrations. The system has the advantages of high precision, extending power and easy manipulation. It has been used in the clinical anesthesia.
Malik, Praveen K; Dewan, Taru; Patidar, Arun Kr; Sain, Ekta
2017-01-01
To evaluate the effect of three different combinations of tip designs and infusion systems in torsional phacoemulsification (INFINITI and CENTURION) in patients with cataract. According to the manufacturer, two unique improvements in the Centurion are: active fluid dynamic management system and use of an intrepid balanced tip. The study specifically aimed to evaluate the beneficial effects, if any, of change in tip design and infusion system individually and in combination on both per-operative parameters as well as endothelial health over 6 months. One hundred and twenty six consenting patients of grade 4.0-6.9 senile cataract were randomized into three groups for phacoemulsification: Group A ( n = 42): Gravity fed infusion system and 45 0 Kelman miniflared ABS phaco tip; Group B ( n = 42): intraocular pressure (IOP) based infusion system and 45 0 Kelman miniflared ABS phaco tip; Group C ( n = 42): IOP based infusion system and 45 0 Intrepid balanced phaco tip. The cumulative dissipated energy (CDE), estimated fluid usage (EFU) and total aspiration time (TAT) were compared peroperatively. The endothelial parameters were followed up postoperatively for six months. The three arms were matched for age ( p = 0.525), gender ( p = 0.96) and grade of cataract ( p = 0.177). Group C was associated with significant reductions in CDE ( p = 0.001), EFU ( p < 0.0005) as well as TAT ( p = 0.001) in comparison to the other groups. All three groups had comparable baseline endothelial cell density ( p = 0.876) and central corneal thickness ( p = 0.561). On post-operative evaluation, although all groups were comparable till 3 months, by 6 months, the percentage losses in endothelial cell density were significantly lower in group C as compared to the other groups. Use of an IOP based phacoemulsification system in association with use of the Intrepid balanced tip reduces the CDE, EFU and TAT in comparison to a gravity fed system with a mini flared tip or IOP based system with a mini flared tip while also providing better endothelial preservation thus favouring the use of an IOP fed system with a balanced tip. Trial registration No.: CTRI/2016/06/007022.
NASA Astrophysics Data System (ADS)
Rentian, Zhang; Honggeng, Zhu; Arnold, Jaap; Linbi, Yao
2010-06-01
Compared with vertical-installed pumps, the propeller (bulb tubular) pump systems can achieve higher hydraulic efficiencies, which are particularly suitable for low-head pumping stations. More than four propeller pumping stations are being, or will be built in the first stage of the S-to-N Water Diversion Project in China, diverting water from Yangtze River to the northern part of China to alleviate water-shortage problems and develop the economy. New structures of propeller pump have been developed for specified pumping stations in Jiangsu and Shandong Provinces respectively and Variable Frequency Drives (VFDs) are used in those pumping stations to regulate operating conditions. Based on the Navier-Stokes equations and the standard k-e turbulent model, numerical simulations of the flow field and performance prediction in the propeller pump system were conducted on the platform of commercial software CFX by using the SIMPLEC algorithm. Through optimal design of bulb dimensions and diffuser channel shape, the hydraulic system efficiency has improved evidently. Furthermore, the structures of propeller pumps have been optimized to for the introduction of conventional as well as permanent magnet motors. In order to improve the hydraulic efficiency of pumping systems, both the pump discharge and the motor diameter were optimized respectively. If a conventional motor is used, the diameter of the pump casing has to be increased to accommodate the motor installed inside. If using a permanent magnet motor, the diameter of motor casing can be decreased effectively without decreasing its output power, thus the cross-sectional area is enlarged and the velocity of flowing water decreased favorably to reduce hydraulic loss of discharge channel and thereby raising the pumping system efficiency. Witness model tests were conducted after numerical optimization on specific propeller pump systems, indicating that the model system hydraulic efficiencies can be improved by 0.5%˜3.7% in different specified operational conditions.
Computer-supported weight-based drug infusion concentrations in the neonatal intensive care unit.
Giannone, Gay
2005-01-01
This article addresses the development of a computerized provider order entry (CPOE)-embedded solution for weight-based neonatal drug infusion developed during the transition from a legacy CPOE system to a customized application of a neonatal CPOE product during a hospital-wide information system transition. The importance of accurate fluid management in the neonate is reviewed. The process of tailoring the system that eventually resulted in the successful development of a computer application enabling weight-based medication infusion calculation for neonates within the CPOE information system is explored. In addition, the article provides guidelines on how to customize a vendor solution for hospitals with neonatal intensive care unit.
Ultra high vacuum pumping system and high sensitivity helium leak detector
Myneni, Ganapati Rao
1997-01-01
An improved helium leak detection method and apparatus are disclosed which increase the leak detection sensitivity to 10.sup.-13 atm cc s.sup.-1. The leak detection sensitivity is improved over conventional leak detectors by completely eliminating the use of o-rings, equipping the system with oil-free pumping systems, and by introducing measured flows of nitrogen at the entrances of both the turbo pump and backing pump to keep the system free of helium background. The addition of dry nitrogen flows to the system reduces backstreaming of atmospheric helium through the pumping system as a result of the limited compression ratios of the pumps for helium.
Pant, Deepanjali; Narani, Krishan Kumar; Sood, Jayashree
2010-01-01
Significant venous air embolism may develop acutely during the perioperative period due to a number of causes such as during head and neck surgery, spinal surgery, improper central venous and haemodialysis catheter handling, etc. The current trend of using self collapsible intravenous (IV) infusion bags instead of the conventional glass or plastic bottles has several advantages, one of thaem being protection against air embolism. We present a 56-year-old man undergoing kidney transplantation, who developed a near fatal venous air embolism during volume resuscitation with normal saline in collapsible IV bags used with rapid infuser system. To our knowledge, this problem with collapsible infusion bags has not been reported earlier. PMID:20532073
Dahm, P O; Nitescu, P V; Appelgren, L K; Curelaru, I D
1998-01-01
There is at present no reliable method for long-term treatment of severe pain following complications of total hip arthroplasty. We explored the long-term use of continuous intrathecal opioid/bupivacaine analgesia in a case not amendable to corrective surgery. A 77-year-old woman, having a total hip arthroplasty, developed refractory nociceptive-neuropathic pain located at the ventral and dorsal aspects of the left hip. Radiographs showed a mandarine-sized intrapelvic mass of bone cement adhering to the roof of the acetabular cup. Further surgery had been declined by the surgeon and by the patient. An 18-gauge Portex intrathecal catheter was inserted, and an intrathecal infusion of 4.75 mg/mL bupivacaine and 0.015 mg/mL buprenorphine was started from a portable Pharmacia-Deltec (St. Paul, Minnesota) pump. The mean daily doses during the treatment period (more than 6 years up to now) were 37 mg for bupivacaine and 0.114 mg for buprenorphine. The intrathecal treatment gave the patient 85-100% pain relief. The patient could transport herself in a wheelchair, was able to perform her own hygiene, receive visits, read, watch television, and also shop and visit restaurants. There has been no need to replace the intrathecal catheter. Intrathecal infusion of opioid/bupivacaine can provide satisfactory long-term analgesia in patients with refractory pain from the hip joint.
Zhu, Ling-Ling; Li, Wei; Song, Ping; Zhou, Quan
2014-01-01
The use of injection devices to administer intravenous or subcutaneous medications is common practice throughout a variety of health care settings. Studies suggest that one-half of all harmful medication errors originate during drug administration; of those errors, about two-thirds involve injectables. Therefore, injection device management is pivotal to safe administration of medications. In this article, the authors summarize the relevant experiences by retrospective analysis of injection device-related near misses and adverse events in the Second Affiliated Hospital of Zhejiang University, School of Medicine, Zhejiang University, People's Republic of China. Injection device-related near misses and adverse events comprised the following: 1) improper selection of needle diameter for subcutaneous injection, material of infusion sets, and pore size of in-line filter; 2) complications associated with vascular access; 3) incidents induced by absence of efficient electronic pump management and infusion tube management; and 4) liquid leakage of chemotherapeutic infusion around the syringe needle. Safe injection drug use was enhanced by multidisciplinary collaboration, especially among pharmacists and nurses; drafting of clinical pathways in selection of vascular access; application of approaches such as root cause analysis using a fishbone diagram; plan-do-check-act and quality control circle; and construction of a culture of spontaneous reporting of near misses and adverse events. Pharmacists must be professional in regards to medication management and use. The depth, breadth, and efficiency of cooperation between nurses and pharmacists are pivotal to injection safety.
1988-07-05
ONITOR FETAL 10952.72 651501C725660 I MNrITOR OXYGEN 783.92 651501C725692 I PLMP BREAST MECHANICAL 1106.39 651501C725694 I STETHOSCOPE ULTRASOJ’D...TODDLEP 1496.12 651501C725969 I MONITOR, PHYSIOLOGICAL SYST, EMSS 2258.21 651501C726026 I FETAL HEART MCONITOR 9937.20 651501C726162 I OXI ETER, PULSE...THERMWTER FARE-EIT ELECTRONIC W/-ARGER 303.55 651501C725211 I MONITOR FETAL PULSE 1305.42 651501C725442 2 PUMP INFUSION VOLLUETRIC 1834.71 65150IC725596 I
NASA Astrophysics Data System (ADS)
Krockenberger, Kyle G.
A heat pump assisted solar thermal system was designed, commissioned, tested and analyzed over a period of two years. The unique system uses solar energy whenever it is available, but switches to heat pump mode at night or whenever there is a lack of solar energy. The solar thermal energy is added by a variety of flat plat solar collectors and an evacuated tube heat pipe solar collector. The working medium in the entire system is a 50% mixture of propylene glycol and water for freeze protection. During the design and evaluation the primary / secondary pumping system was the focus of the evaluation. Testing within this research focused on the operation modes, pump stability, and system efficiency. It was found that the system was in full operation, the pumps were stable and that the efficiency factor of the system was 1.95.
NASA Technical Reports Server (NTRS)
Thomas, N. C.; Crosmer, W. E.; Nowak, D.
1973-01-01
A survey of mechanical vacuum pumps was completed. A small Roots blower for flight mass spectrometer applications was evaluated with respect to system operating parameters in a number of different modes of operation. The survey indicated that a metal bellows pump might be a viable alternative for the systems requirements. The results of the study are given, including current status of possible flight-type pumps, a systems analysis using available pumps, and recommendations for fabrication and tests of a potential flight-type pump.
Large-capacity pump vaporizer for liquid hydrogen and nitrogen
NASA Technical Reports Server (NTRS)
Hauser, J. A.
1970-01-01
Pump vaporizer system delivers 500 standard cubic feet per minute of hydrogen or nitrogen, one system delivers both gases. Vacuum-jacketed pump discharges liquid hydrogen or liquid nitrogen into vaporizing system heated by ambient air. Principal characteristics of the flow and discharge system, pump, and vaporizer are given.
Drumheller, Douglas S.
1998-01-01
An improved well-pump for geothermal wells, an alignment system for a well-pump, and to a method for aligning a rotor and stator within a well-pump, wherein the well-pump has a whistle assembly formed at a bottom portion thereof, such that variations in the frequency of the whistle, indicating misalignment, may be monitored during pumping.