Röhrich, J; Schimmel, I; Zörntlein, S; Becker, J; Drobnik, S; Kaufmann, T; Kuntz, V; Urban, R
2010-05-01
Cannabinoid concentrations in blood and urine after passive exposure to cannabis smoke under real-life conditions were investigated in this study. Eight healthy volunteers were exposed to cannabis smoke for 3 h in a well-attended coffee shop in Maastricht, Netherlands. An initial blood and urine sample was taken from each volunteer before exposure. Blood samples were taken 1.5, 3.5, 6, and 14 h after start of initial exposure, and urine samples were taken after 3.5, 6, 14, 36, 60, and 84 h. The samples were subjected to immunoassay screening for cannabinoids and analyzed using gas chromatography-mass spectrometry (GC-MS) for Delta(9)-tetrahydrocannabinol (THC), 11-nor-hydroxy-Delta(9)-tetrahydrocannabinol (THC-OH), and 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH). It could be demonstrated that all volunteers absorbed THC. However, the detected concentrations were rather small. None of the urine samples produced immunoassay results above the cutoff concentration of 25 ng/mL. THC-COOH concentrations up to 5.0 and 7.8 ng/mL before and after hydrolysis, respectively, were found in the quantitative GC-MS analysis of urine. THC could be detected in trace amounts close to the detection limit of the used method in the first two blood samples after initial exposure (1.5 and 3.5 h). In the 6 h blood samples, THC was not detectable anymore. THC-COOH could be detected after 1.5 h and was still found in 3 out of 8 blood samples after 14 h in concentrations between 0.5 and 1.0 ng/mL.
Domingo, Olwen; Stöver, Andreas; Roider, Gabriele; Graw, Matthias
2017-03-01
In our study, we analysed the effect of a variety of storage conditions on the methaemoglobin (MetHb) content of blood samples obtained from altogether 110 deceased subjects with diverse causes of death, including three 'poppers'-related fatalities. The obtained results were compared to data from blood samples of six living, healthy subjects. Results obtained from the spectrophotometric measurement of blood MetHb content suggest that storage at room temperature (RT) and storage at -20 °C result in either highly fluctuating values, as was the case for the RT samples, or values much higher than the initial MetHb concentrations when stored at -20 °C. Blood samples at 4 °C showed more stable MetHb levels, which, however, increased with up to 4 % of the initial value after only 3 weeks of storage. These factors pose a problem in forensic toxicology, especially in nitrite abuse cases, where the involvement of such substance abuse is often unknown at the time of blood sampling and thus often requires longer storage times. Nevertheless, even after the storage of blood samples over several months at 4 and -20 °C, 'poppers' cases still show a significantly higher MetHb concentration as compared to non-'poppers' samples that were stored for the same time period under identical conditions.
Infectious agent screening in canine blood donors in the United Kingdom.
Crawford, K; Walton, J; Lewis, D; Tasker, S; Warman, S M
2013-08-01
Transfusion of blood products is an important component of veterinary emergency medicine. Donors must be carefully selected to minimise risk of transmission of blood-borne infectious agents. This study was devised to assess the prevalence of such agents in healthy, non-travelled UK dogs screened as prospective donors. Ethylenediaminetetraacetic acid blood samples from dogs donating blood between August 2007 and January 2012 were screened by polymerase chain reaction for haemotropic mycoplasmas, Bartonella, Babesia, Leishmania, Ehrlichia and Anaplasma spp. Dogs with positive or inconclusive results underwent repeat polymerase chain reaction testing. Four of 262 dogs had positive or inconclusive results at initial screening. Repeat polymerase chain reaction testing in each dog was negative, and none of the dogs developed clinical signs of disease. The positive results on initial screening may have represented false positives from sample contamination or amplification of non-target DNA. It is also possible that dogs were infected at initial sampling but successfully cleared infection before repeat testing. The low number of positive results obtained suggests that prevalence of these agents in a population of healthy UK dogs is low and that use of blood products is unlikely to represent a significant risk of transmission of these diseases. © 2013 British Small Animal Veterinary Association.
Early infant HIV diagnosis and entry to HIV care cascade in Thailand: an observational study.
Sirirungsi, Wasna; Khamduang, Woottichai; Collins, Intira Jeannie; Pusamang, Artit; Leechanachai, Pranee; Chaivooth, Suchada; Ngo-Giang-Huong, Nicole; Samleerat, Tanawan
2016-06-01
Early infant diagnosis of HIV is crucial for timely initiation of antiretroviral therapy (ART) in infected children who are at high risk of mortality. Early infant diagnosis with dried blood spot testing was provided by the National AIDS Programme in Thailand from 2007. We report ART initiation and vital status in children with HIV after 7 years of rollout in Thailand. Dried blood spot samples were collected from HIV-exposed children in hospitals in Thailand and mailed to the Faculty of Associated Medical Sciences, Chiang Mai University, where HIV DNA was assessed with real-time PCR to establish HIV infection. We linked data from children with an HIV infection to the National AIDS Programme database to ascertain ART and vital status. Between April 5, 2007, and Oct 1, 2014, 16 046 dried blood spot samples were sent from 8859 children in 364 hospitals in Thailand. Median age at first dried blood spot test was 2·1 (IQR 1·8-2·5) months. Of 7174 (81%) children with two or more samples, 223 (3%) were HIV positive (including five unconfirmed). Of 1685 (19%) children with one sample, 70 (4%) were unconfirmed positive. Of 293 (3%) children who were HIV positive, 220 (75%) registered for HIV care and 170 (58%) initiated ART. Median age at ART initiation decreased from 14·2 months (IQR 10·2-25·6) in 2007 to 6·1 months (4·2-9·2) in 2013, and the number of children initiating ART aged younger than 1 year increased from five (33%) of 15 children initiating ART in 2007 to ten (83%) of 12 initiating ART in 2013. 15 (9%) of 170 children who initiated ART died and 16 (32%) of 50 who had no ART record died. Early infant diagnosis with dried blood spot testing had high uptake in primary care settings. Further improvement of linkage to HIV care is needed to ensure timely treatment of all children with an HIV infection. None. Copyright © 2016 Elsevier Ltd. All rights reserved.
Post-analytical stability of 23 common chemistry and immunochemistry analytes in incurred samples.
Nielsen, Betina Klint; Frederiksen, Tina; Friis-Hansen, Lennart; Larsen, Pia Bükmann
2017-12-01
Storage of blood samples after centrifugation, decapping and initial sampling allows ordering of additional blood tests. The pre-analytic stability of biochemistry and immunochemistry analytes has been studied in detail, but little is known about the post-analytical stability in incurred samples. We examined the stability of 23 routine analytes on the Dimension Vista® (Siemens Healthineers, Denmark): 42-60 routine samples in lithium-heparin gel tubes (Vacutainer, BD, USA) were centrifuged at 3000×g for 10min. Immediately after centrifugation, initial concentration of analytes were measured in duplicate (t=0). The tubes were stored decapped at room temperature and re-analyzed after 2, 4, 6, 8 and 10h in singletons. The concentration from reanalysis were normalized to initial concentration (t=0). Internal acceptance criteria for bias and total error were used to determine stability of each analyte. Additionally, evaporation from the decapped blood collection tubes and the residual platelet count in the plasma after centrifugation were quantified. We report a post-analytical stability of most routine analytes of ≥8h and do therefore - with few exceptions - suggest a standard 8hour-time limit for reordering and reanalysis of analytes in incurred samples. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
The Blood Donation Ambivalence Survey: measuring conflicting attitudes about giving blood.
Fox, K R; Himawan, L K; France, C R
2017-05-18
This study was designed to develop and conduct initial validation testing for a novel measure of ambivalence about donating blood. Previous studies of living organ, bone marrow and stem cell donors have identified donation-related ambivalence as a predictor of decisions about donation and post-donation outcomes. Ambivalence about blood donation has not received the same attention. In Study 1, a sample of young adults (N = 396) were administered test items of ambivalence, and exploratory (EFA) and confirmatory factor analyses (CFA) were performed to identify the Blood Donation Ambivalence Survey. In Study 2, a separate sample of young adults (N = 241) completed the Blood Donation Ambivalence Survey in addition to questionnaires assessing known predictors of blood donation. Exploratory and confirmatory factor analyses indicated a two-factor structure reflecting commitment to donating blood and indecision about giving blood. The commitment subscale was positively related to known predictors of increased donation behaviour (e.g. donation intention, self-efficacy), whereas the indecision subscale was positively related to known predictors of decreased donation behaviour (e.g. donation anxiety, negative affect). Furthermore, a history of blood donation was associated with greater commitment and less indecision. The present findings provide strong initial support for the reliability and validity of a novel measure of blood donor ambivalence. © 2017 British Blood Transfusion Society.
Zhu, Li-Wei; Yang, Xue-Mei; Xu, Xiao-Qin; Xu, Jian; Lu, Huang-Jun; Yan, Li-Xing
2008-10-01
This study was aimed to analyze the results of false positive reaction in bacterial detection of blood samples with BacT/ALERT 3D system, to evaluate the specificity of this system, and to decrease the false positive reaction. Each reaction flasks in past five years were processed for bacteria isolation and identification. When the initial cultures were positive, the remaining samples and the corresponding units were recultured if still available. 11395 blood samples were detected. It is worthy of note that the incubator temperature should be stabilized, avoiding fluctuation; when the cultures were alarmed, the reaction flasks showed be kept some hours for further incubation so as to trace a sharply increasing signal to support the judgement of true bacterial growth. The results indicated that 122 samples (1.07%) wee positive at initial culture, out of them 107 samples (88.7%) were found bacterial, and 15 samples (12.3%) were found nothing. The detection curves of positive samples resulted from bacterial growth showed ascent. In conclusion, maintenance of temperature stability and avoidance of temperature fluctuation in incubator could decrease the occurrence of false-positive reaction in detection process. The reaction flasks with positive results at initial culture should be recultured, and whether existence of a sharply ascending logarilhimic growth phase in bacterial growth curve should be further detected, which are helpful to distinguish false-positive reactions from true positive, and thus increase the specificity of the BacT/ALERT system.
Fagge, Timothy J; Barclay, G Robin; Stove, G Colin; Stove, Gordon; Robinson, Michael J; Head, Mark W; Ironside, James W; Turner, Marc L
2007-01-01
Background Sub-clinical variant Creutzfeldt-Jakob disease (vCJD) infection and reports of vCJD transmission through blood transfusion emphasise the need for blood screening assays to ensure the safety of blood and transplanted tissues. Most assays aim to detect abnormal prion protein (PrPSc), although achieving required sensitivity is a challenge. Methods We have used innovative Atomic Dielectric Resonance Spectroscopy (ADRS), which determines dielectric properties of materials which are established by reflectivity and penetration of radio/micro waves, to analyse blood samples from patients and controls to identify characteristic ADR signatures unique to blood from vCJD and to sCJD patients. Initial sets of blood samples from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) were screened as training samples to determine group-specific ADR characteristics, and provided a basis for classification of blinded sets of samples. Results Blood sample groups from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) screened by ADRS were classified with 100% specificity and sensitivity, discriminating these by a co-variance expert analysis system. Conclusion ADRS appears capable of recognising and discriminating serum samples from vCJD, sCJD, non-CJD neurological diseases, and normal healthy adults, and might be developed to provide a system for primary screening or confirmatory assay complementary to other screening systems. PMID:17760958
Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C
2015-12-01
Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.
Program adherence and effectiveness of a commercial nutrition program: the metabolic balance study.
Meffert, Cornelia; Gerdes, Nikolaus
2010-01-01
Objective. To assess the effectiveness of a commercial nutrition program in improving weight, blood lipids, and health-related quality of life (HRQOL). Methods. Prospective observational study with followup after 1, 3, 6, and 12 months with data from questionnaires and blood samples. Subjects. After 12 months, we had data from 524 subjects (= 60.6% of the initial samples). 84.1% of the subjects were women. The average BMI at baseline was 30.3 (SD = 5.7). Results. After 12 months, the average weight loss was 6.8 kg (SD = 7.1 kg). Program adherence declined over time but was still high after 12 months and showed a positive linear correlation with weight loss. Relevant blood parameters as well as HRQOL improved significantly. Conclusion. After 12 months, nearly two thirds of the samples had achieved >5% reduction of their initial weights. The high degree of program adherence is probably due to personal counseling and individually designed nutrition plans provided by the program.
Rafkin, Lisa E.; Matheson, Della; Steck, Andrea K.; Yu, Liping; Henderson, Courtney; Beam, Craig A.; Boulware, David C.
2015-01-01
Abstract Background: Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot–based screening to identify islet autoantibody–positive relatives potentially eligible for inclusion in prevention trials. Materials and Methods: Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Results: Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Conclusions: Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies. PMID:26375197
Stress-induced suppression of testosterone secretion in male alligators.
Lance, V A; Elsey, R M
1986-08-01
In order to test the effect of acute stress on gonadal hormone secretion in reptiles, six mature male alligators were captured, and a blood sample was taken within 5 min of capture. Additional blood samples were taken at timed intervals for up to 41 hr, and plasma testosterone and corticosterone were measured by radioimmunoassay. Plasma testosterone declined to 50% of the initial value by 4 hr and dropped to less than 10% of initial by 24 hr. Plasma corticosterone increased during the first 12 hr, declined at 24 hr, and rose again at 40 hr. Blood samples from male alligators collected in North and South Carolina, south Florida, and in south Louisiana in two consecutive breeding seasons were also assayed for testosterone and corticosterone. In these populations there were significant differences in mean plasma testosterone and corticosterone levels. Elevated corticosterone levels were consistently seen in alligators caught in traps and from which a blood sample was taken several hours later. Plasma testosterone, although consistently lower in trapped alligators, did not show a negative correlation with plasma corticosterone. Farm-reared alligators bled once, released, and bled again at 24 hr also showed a highly significant suppression of testosterone secretion. These results demonstrate that stress has a rapid and dramatic effect on testicular steroid secretion in both farm-reared and wild alligators.
Fassunke, Jana; Ihle, Michaela Angelika; Lenze, Dido; Lehmann, Annika; Hummel, Michael; Vollbrecht, Claudia; Penzel, Roland; Volckmar, Anna-Lena; Stenzinger, Albrecht; Endris, Volker; Jung, Andreas; Lehmann, Ulrich; Zeugner, Silke; Baretton, Gustavo; Kreipe, Hans; Schirmacher, Peter; Kirchner, Thomas; Dietel, Manfred; Büttner, Reinhard; Merkelbach-Bruse, Sabine
2017-10-01
The European Commision (EC) recently approved osimertinib for the treatment of adult patients with locally advanced or metastatic non-small-cell lung cancer (NSCLC) harboring EGFR T790M mutations. Besides tissue-based testing, blood samples containing cell-free circulating tumor DNA (ctDNA) can be used to interrogate T790M status. Herein, we describe the conditions and results of a round robin trial (RRT) for T790M mutation testing in NSCLC tissue specimens and peripheral blood samples spiked with cell line DNA mimicking tumor-derived ctDNA. The underlying objectives of this two-staged external quality assessment (EQA) approach were (a) to evaluate the accuracy of T790M mutations testing across multiple centers and (b) to investigate if a liquid biopsy-based testing for T790M mutations in spiked blood samples is feasible in routine diagnostic. Based on a successfully completed internal phase I RRT, an open RRT for EGFR T790M mutation testing in tumor tissue and blood samples was initiated. In total, 48 pathology centers participated in the EQA. Of these, 47 (97.9%) centers submitted their analyses within the pre-defined time frame and 44 (tissue), respectively, 40 (plasma) successfully passed the test. The overall success rates in the RRT phase II were 91.7% (tissue) and 83.3% (blood), respectively. Thirty-eight out of 48 participants (79.2%) successfully passed both parts of the RRT. The RRT for blood-based EGFR testing initiated in Germany is, to the best of our knowledge, the first of his kind in Europe. In summary, our results demonstrate that blood-based genotyping for EGFR resistance mutations can be successfully integrated in routine molecular diagnostics complementing the array of molecular methods already available at pathology centers in Germany.
Human blood RNA stabilization in samples collected and transported for a large biobank
2012-01-01
Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904
Plasma catecholamines and plasma corticosterone following restraint stress in juvenile alligators.
Lance, V A; Elsey, R M
1999-05-01
Ten juvenile alligators, mean body mass 793 g, hatched from artificially incubated eggs and raised under controlled conditions, were held out of water with their jaws held closed for 48 hr. An initial blood sample was taken and further samples collected at 1, 2, 4, 8, 24, and 48 hr. Epinephrine, norepinephrine, and dopamine were measured in plasma aliquots of 1.5 ml using high pressure liquid chromatography with electrochemical detection. Corticosterone was measured by radioimmunoassay. Plasma glucose was measured using the Trinder method and plasma calcium, cholesterol, and triglycerides were measured in an autoanalyzer. Epinephrine was about 4 ng/ml at the initial bleed, but declined steadily to < 0.4 ng/ml by 24 hr. Norepinephrine was also about 4 ng/ml at the initial bleed, but rose to over 8 ng/ml at 1 hr, and then declined to < 0.2 ng/ml at 24 hr. A second, but smaller increase in plasma norepinephrine was seen at 48 hr. Plasma dopamine was low at the initial bleed (< 0.7 ng/ml), rose to over 8 ng/ml at 1 hr, then declined to < 0.2 ng/ml. Plasma corticosterone rose progressively for the first 4 hr, declined at 8 hr and 24 hr, then rose again at 48 hr. Plasma glucose rose significantly by 24 hr and remained elevated for 48 hr. Plasma calcium increased at 1, 2, and 4 hr then returned to levels not significantly different from the initial sample at 24 and 48 hr. The white blood cells showed changes indicating immune system suppression. By the end of the treatment the hetorophil/lymphocyte ratio increased to 4.7. These results suggest that handling alligators, taking multiple blood samples, and keeping them restrained for more than 8 hr is a severe stress to the animals.
Chapman, Kent; Favaloro, Emmanuel J
2018-05-01
The Multiplate is a popular instrument that measures platelet function using whole blood. Potentially considered a point of care instrument, it is also used by hemostasis laboratories. The instrument is usually utilized to assess antiplatelet medication or as a screen of platelet function. According to the manufacturer, testing should be performed within 0.5-3 hours of blood collection, and preferably using manufacturer provided hirudin tubes. We report time-associated reduction in platelet aggregation using the Multiplate and hirudin blood collection tubes, for all the major employed agonists. Blood for Multiplate analysis was collected into manufacturer supplied hirudin tubes, and 21 consecutive samples assessed using manufacturer supplied agonists (ADP, arachidonic acid, TRAP, collagen and ristocetin), at several time-points post-sample collection within the recommended test time period. Blood was also collected into EDTA as a reference method for platelet counts, with samples collected into sodium citrate and hirudin used for comparative counts. All platelet agonists showed a diminution of response with time. Depending on the agonist, the reduction caused 5-20% and 22-47% of responses initially in the normal reference range to fall below the reference range at 120min and 180min, respectively. Considering any agonist, 35% and 67% of initially "normal" responses became 'abnormal' at 120 min and 180 min, respectively. Platelet counts showed generally minimal changes in EDTA blood, but were markedly reduced over time in both citrate and hirudin blood, with up to 40% and 60% reduction, respectively, at 240 min. The presence of platelet clumping (micro-aggregate formation) was also observed in a time dependent manner, especially for hirudin. In conclusion, considering any platelet agonist, around two-thirds of samples can, within the recommended 0.5-3 hour testing window post-blood collection, yield a reduction in platelet aggregation that may lead to a change in interpretation (i.e., normal to reduced). Thus, the stability of Multiplate testing can more realistically be considered as being between 30-120 min of blood collection for samples collected into hirudin.
Fever in the test tube--towards a human(e) pyrogen test.
Schindler, Stephanie; Fennrich, Stefan; Crameri, Reto; Jungi, Thomas W; Montag, Thomas; Hartung, Thomas
2007-01-01
The human whole blood IL-1 test exploits the reaction of monocytes/macrophages for the detection of pyrogens: human whole blood taken from healthy volunteers is incubated in the presence of the test sample in any form, be it a solution, a powder or even solid material. Pyrogenic contaminations initiate the release of the "endogenous pyrogen" Interleukin-1beta determined by ELISA after incubation. In order to understand any differences between the pyrogenic activity in this test and the existing live rabbit test (species differences versus aberrant response of the particular blood sample), the rabbit whole blood test was developed. This approach could also help to avoid the use of putatively infectious human blood for pyrogen testing in vitro.
Design of portable ultraminiature flow cytometers for medical diagnostics
NASA Astrophysics Data System (ADS)
Leary, James F.
2018-02-01
Design of portable microfluidic flow/image cytometry devices for measurements in the field (e.g. initial medical diagnostics) requires careful design in terms of power requirements and weight to allow for realistic portability. True portability with high-throughput microfluidic systems also requires sampling systems without the need for sheath hydrodynamic focusing both to avoid the need for sheath fluid and to enable higher volumes of actual sample, rather than sheath/sample combinations. Weight/power requirements dictate use of super-bright LEDs with top-hat excitation beam architectures and very small silicon photodiodes or nanophotonic sensors that can both be powered by small batteries. Signal-to-noise characteristics can be greatly improved by appropriately pulsing the LED excitation sources and sampling and subtracting noise in between excitation pulses. Microfluidic cytometry also requires judicious use of small sample volumes and appropriate statistical sampling by microfluidic cytometry or imaging for adequate statistical significance to permit real-time (typically in less than 15 minutes) initial medical decisions for patients in the field. This is not something conventional cytometry traditionally worries about, but is very important for development of small, portable microfluidic devices with small-volume throughputs. It also provides a more reasonable alternative to conventional tubes of blood when sampling geriatric and newborn patients for whom a conventional peripheral blood draw can be problematical. Instead one or two drops of blood obtained by pin-prick should be able to provide statistically meaningful results for use in making real-time medical decisions without the need for blood fractionation, which is not realistic in the doctor's office or field.
The relationships between air exposure, negative pressure, and hemolysis.
Pohlmann, Joshua R; Toomasian, John M; Hampton, Claire E; Cook, Keith E; Annich, Gail M; Bartlett, Robert H
2009-01-01
The purpose of this study was to describe the hemolytic effects of both negative pressure and an air-blood interface independently and in combination in an in vitro static blood model. Samples of fresh ovine or human blood (5 ml) were subjected to a bubbling air interface (0-100 ml/min) or negative pressure (0-600 mm Hg) separately, or in combination, for controlled periods of time and analyzed for hemolysis. Neither negative pressure nor an air interface alone increased hemolysis. However, when air and negative pressure were combined, hemolysis increased as a function of negative pressure, the air interface, and time. Moreover, when blood samples were exposed to air before initiating the test, hemolysis was four to five times greater than samples not preexposed to air. When these experiments were repeated using freshly drawn human blood, the same phenomena were observed, but the hemolysis was significantly higher than that observed in sheep blood. In this model, hemolysis is caused by combined air and negative pressure and is unrelated to either factor alone.
A screening method for biotinidase deficiency in newborns.
Heard, G S; Secor McVoy, J R; Wolf, B
1984-01-01
We describe a method for neonatal screening for biotinidase (EC 3.5.1.12) deficiency. Biotinidase activity is assessed colorimetrically from dried samples of whole blood spotted on the same filter papers as used in the neonatal screening for phenylketonuria. After the reaction, samples from normal infants are characteristically purple, whereas those from affected individuals are straw-colored. To confirm the deficiency, the enzyme is quantitatively assayed in additional blood spots or serum. A pilot study has been initiated with samples obtained by the Commonwealth of Virginia for phenylketonuria testing.
Clinical survey of antibodies against red blood cells in horses after homologous blood transfusion.
Wong, P L; Nickel, L S; Bowling, A T; Steffey, E P
1986-12-01
Serum samples of 20 horses were evaluated for antibodies against RBC after homologous blood transfusion. Transfusion-associated antibodies against RBC were detected in 10 horses. Antibodies recognizing horse blood group antigens Aa, Ae, Db, and Dc were identified. Antibodies against Aa were found in all samples from Aa-negative horses that were transfused with Aa-positive RBC. Antibodies against Aa persisted for at least 1 year after transfusion. Antibodies against Ae were detected in 7 of 8 horses transfused with Ae-positive RBC. Initial appearance and persistence of antibodies against Ae differed among the horses; antibodies were initially detected 1 week to 154 weeks after transfusion and disappeared as early as 4 weeks after transfusion. Antibodies against Db or Dc were detected in less than or equal to 33% of the horses that lacked Db or Dc antigens and were transfused with Db- or Dc-positive RBC. Antibodies against Db and Dc were initially detected in sera later than were the A-system antibodies. Three mares with transfusion-associated antibodies subsequently produced healthy offspring. Two foals had RBC antigens corresponding to their dam's alloantibodies; maternal colostrum with antibodies against Aa was withheld from the Aa-positive foal. The Db-positive foal remained healthy after nursing the mare with serum antibodies against Db.
Metherel, Adam H; Stark, Ken D
2015-03-01
Fingertip prick whole blood collection on chromatography paper is amenable to high-throughput fatty acid (FA) profiling for large clinical and field studies. However, sample storage is problematic because highly unsaturated FAs (HUFAs) in erythrocytes rapidly degrade in samples stored at -20°C. The aim of the current study was to determine the mechanism of HUFA degradation and to develop prevention protocols. Free fatty acid (FFA) standards and whole blood reference material from a single participant were used to examine sample storage at -20°C for up to 90 d in triplicate. Iron chelation with deferoxamine (0-5000 μg), antioxidant protection with butylated hydroxytoluene (50 μg), cryopreservation with glycerol, and blood drying were examined using whole blood on chromatography strips. Biological replicate blood samples from additional participants (n = 6) with a range of ω-3 (n-3) HUFA concentrations were similarly assessed. FFAs were relatively stable when stored on chromatography strips at -20°C. Glycerol treatment prevented HUFA degradation in whole blood reference material for 30 d (45 ± 0.4 to 46.8 ± 0.1, means ± SDs) compared to untreated saline controls (45.9 ± 1.0 to 6.8 ± 0.2). Pretreatment of paper for blood spots with deferoxamine and drying blood before storage slowed, but not entirely prevented, HUFA degradation over 30 d to 22% and 19% below baseline, respectively, compared to 86-92% in the controls. Protection against HUFA degradation with blood drying and glycerol treatment was confirmed in the biological replicate study and confirmed by prevention of cell lysis. HUFA degradation during storage at -20°C appears to be due to hemolysis and subsequent iron-initiated peroxidation. This degradation may be prevented by glycerol, iron chelation, and/or dried blood spotting. A more thorough understanding of methods to prevent degradation during storage is critical with increasing use of FA profiling in large clinical studies. © 2015 American Society for Nutrition.
Detection of bacteraemias during non-surgicalroot canal treatment.
Savarrio, L; Mackenzie, D; Riggio, M; Saunders, W P; Bagg, J
2005-04-01
Some dental procedures initiate a bacteraemia. In certain compromised patients, this bacteraemia may lead to distant site infections, most notably infective endocarditis. To investigate whether a detectable bacteraemia was produced during non-surgical root canal therapy. Thirty patients receiving non-surgical root canal therapy were studied. Three blood samples were taken per patient: pre-operatively, peri-operatively and post-operatively. In addition, a paper point sample was collected from the root canal. The blood samples were cultured by pour plate and blood bottle methods. The isolated organisms were identified by standard techniques. Blood samples were analysed for the presence of bacterial DNA by the polymerase chain reaction (PCR). In two cases where the same species of organism was identified in the root canal and the bloodstream, the isolates were typed by pulsed field gel electrophoresis (PFGE). By conventional culturing, a detectable bacteraemia was present in 9 (30%) of the 30 patients who had no positive pre-operative control blood sample. In 7 (23.3%) patients, the same species of organism was identified in both the bloodstream and in the paper point sample from the root canal system. Overall, PCR gave lower detection rates compared with conventional culture, with 10 of 90 (11%) of the blood samples displaying bacterial DNA. PFGE typing was undertaken for two pairs of culture isolates from blood and paper points; these were found to be genetically identical. Non-surgical root canal treatment may invoke a detectable bacteraemia.
Morin, Alexander M; Gatev, Evan; McEwen, Lisa M; MacIsaac, Julia L; Lin, David T S; Koen, Nastassja; Czamara, Darina; Räikkönen, Katri; Zar, Heather J; Koenen, Karestan; Stein, Dan J; Kobor, Michael S; Jones, Meaghan J
2017-01-01
Cord blood is a commonly used tissue in environmental, genetic, and epigenetic population studies due to its ready availability and potential to inform on a sensitive period of human development. However, the introduction of maternal blood during labor or cross-contamination during sample collection may complicate downstream analyses. After discovering maternal contamination of cord blood in a cohort study of 150 neonates using Illumina 450K DNA methylation (DNAm) data, we used a combination of linear regression and random forest machine learning to create a DNAm-based screening method. We identified a panel of DNAm sites that could discriminate between contaminated and non-contaminated samples, then designed pyrosequencing assays to pre-screen DNA prior to being assayed on an array. Maternal contamination of cord blood was initially identified by unusual X chromosome DNA methylation patterns in 17 males. We utilized our DNAm panel to detect contaminated male samples and a proportional amount of female samples in the same cohort. We validated our DNAm screening method on an additional 189 sample cohort using both pyrosequencing and DNAm arrays, as well as 9 publically available cord blood 450K data sets. The rate of contamination varied from 0 to 10% within these studies, likely related to collection specific methods. Maternal blood can contaminate cord blood during sample collection at appreciable levels across multiple studies. We have identified a panel of markers that can be used to identify this contamination, either post hoc after DNAm arrays have been completed, or in advance using a targeted technique like pyrosequencing.
To mix or not to mix venous blood samples collected in vacuum tubes?
Parenmark, Anna; Landberg, Eva
2011-09-08
There are recommendations to mix venous blood samples by inverting the tubes immediately after venipuncture. Though mixing allows efficient anticoagulation in plasma tubes and fast initiation of coagulation in serum tubes, the effect on laboratory analyses and risk of haemolysis has not been thoroughly evaluated. Venous blood samples were collected by venipuncture in vacuum tubes from 50 patients (10 or 20 patients in each group). Four types of tubes and 18 parameters used in routine clinical chemistry were evaluated. For each patient and tube, three types of mixing strategies were used: instant mixing, no mixing and 5 min of rest followed by mixing. Most analyses did not differ significantly in samples admitted to different mixing strategies. Plasma lactate dehydrogenase and haemolysis index showed a small but significant increase in samples omitted to instant mixing compared to samples without mixing. However, in one out of twenty non-mixed samples, activated partial thromboplastin time was seriously affected. These results indicate that mixing blood samples after venipuncture is not mandatory for all types of tubes. Instant mixing may introduce interference for those analyses susceptible to haemolysis. However, tubes with liquid-based citrate buffer for coagulation testing should be mixed to avoid clotting.
Chakrabarty, P; Rudra, S; Hossain, M A; Begum, S A; Mirza, T T; Rudra, M
2015-04-01
Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from voluntary and replacement blood donors & HIV-infected patients (positive samples from BSMMU, Dhaka). Five rapid HIV assays: Determine™ HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1-2.0 (PMC Medical India Pvt Ltd.), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold™ HIV-1/2 (Biotech) were evaluated between 1st February to 30th June, 2013 using 400 whole blood samples from voluntary and replacement blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Only 01 sample including ten positive samples from BSMMU were confirmed HIV-1 antibody positive, while 399 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold™ was 100% (95% CI; 99.1-100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2-99.9) and 97.7% (95% CI; 95.7-98.9) respectively, which increased to 100% (95% CI; 99.1-100) on repeat testing. The initial specificity of the Uni-Gold™ assay was 100% (95% CI; 99.6-100) while specificities were 99.6% (95% CI; 99-99.9), 99.4% (95% CI; 98.8-99.7), 99.6% (95% CI; 99-99.9) and 99.8% (95% CI; 99.3-99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold™, Determine and SD Bioline assays. An alternative confirmatory HIV testing strategy based on initial testing on either SD Bioline or Determine assays followed by testing of reactive samples on the Determine or SD Bioline gave 100% sensitivity (95% CI; 99.1-100) and 100% specificity (95% CI; 96-99.1) with Uni-Gold™ as tiebreaker for discordant results.
The Relationships between Air Exposure, Negative Pressure and Hemolysis
Pohlmann, Joshua R.; Toomasian, John M.; Hampton, Claire E.; Cook, Keith E.; Annich, Gail M.; Bartlett, Robert H.
2013-01-01
The purpose of this study was to describe the hemolytic effects of both negative pressure and an air-blood interface independently and in combination in an in-vitro static blood model. Samples of fresh ovine or human blood (5 mL) were subjected to a bubbling air interface (0–100 mL/min) or negative pressure (0–600 mmHg) separately, or in combination, for controlled periods of time, and analyzed for hemolysis. Neither negative pressure nor an air interface alone increased hemolysis. However, when air and negative pressure were combined, hemolysis increased as a function of negative pressure, the air interface, and time. Moreover, when blood samples were exposed to air prior to initiating the test, hemolysis was 4–5 times greater than samples not pre-exposed to air. When these experiments were repeated using freshly drawn human blood the same phenomena were observed, but the hemolysis was significantly higher than that observed in sheep blood. In this model, hemolysis is caused by combined air and negative pressure and is unrelated to either factor alone. PMID:19730004
West Nile virus blood transfusion-related infection despite nucleic acid testing.
Macedo de Oliveira, Alexandre; Beecham, Brady D; Montgomery, Susan P; Lanciotti, Robert S; Linnen, Jeffrey M; Giachetti, Cristina; Pietrelli, Larry A; Stramer, Susan L; Safranek, Thomas J
2004-12-01
A case of West Nile virus (WNV) encephalitis associated with transfusion of blood that did not react when tested for WNV by minipool (MP) nucleic acid testing (NAT) is described. A Nebraska man developed clinical encephalitis 13 days after surgery and transfusion of 26 blood components. Antibody testing confirmed WNV infection. An investigation was initiated to determine the source of this infection. The patient's family members were interviewed to identify risk factors for WNV infection. Residual samples were retested for WNV RNA using transcription-mediated amplification (TMA) assay and two polymerase chain reaction (PCR) assays. Blood donors' follow-up serum samples were collected. All samples were tested for WNV-specific immunoglobulin M antibodies. The patient's family denied recent mosquito exposure. The 20 blood components collected after July 2003 did not react when tested for WNV in a six-member MP-NAT at the time of donation. Retrospective individual testing identified one sample as WNV-reactive by the TMA assay and one of the PCR assays. Seroconversion was demonstrated in the donor associated with this sample. WNV RNA detection by individual donation NAT demonstrates viremic blood escaping MP-NAT and supports transfusion-related WNV transmission. MP-NAT may not detect all WNV-infected blood donors, allowing WNV transmission to continue at low levels. WNV NAT assays might vary in sensitivity and pooling donations could further impact test performance. Understanding MP NAT limitations can improve strategies to maintain safety of the blood supply in the United States.
Impact of Educational Activities in Reducing Pre-Analytical Laboratory Errors: A quality initiative.
Al-Ghaithi, Hamed; Pathare, Anil; Al-Mamari, Sahimah; Villacrucis, Rodrigo; Fawaz, Naglaa; Alkindi, Salam
2017-08-01
Pre-analytic errors during diagnostic laboratory investigations can lead to increased patient morbidity and mortality. This study aimed to ascertain the effect of educational nursing activities on the incidence of pre-analytical errors resulting in non-conforming blood samples. This study was conducted between January 2008 and December 2015. All specimens received at the Haematology Laboratory of the Sultan Qaboos University Hospital, Muscat, Oman, during this period were prospectively collected and analysed. Similar data from 2007 were collected retrospectively and used as a baseline for comparison. Non-conforming samples were defined as either clotted samples, haemolysed samples, use of the wrong anticoagulant, insufficient quantities of blood collected, incorrect/lack of labelling on a sample or lack of delivery of a sample in spite of a sample request. From 2008 onwards, multiple educational training activities directed at the hospital nursing staff and nursing students primarily responsible for blood collection were implemented on a regular basis. After initiating corrective measures in 2008, a progressive reduction in the percentage of non-conforming samples was observed from 2009 onwards. Despite a 127.84% increase in the total number of specimens received, there was a significant reduction in non-conforming samples from 0.29% in 2007 to 0.07% in 2015, resulting in an improvement of 75.86% ( P <0.050). In particular, specimen identification errors decreased by 0.056%, with a 96.55% improvement. Targeted educational activities directed primarily towards hospital nursing staff had a positive impact on the quality of laboratory specimens by significantly reducing pre-analytical errors.
A rate-based transcutaneous CO2 sensor for noninvasive respiration monitoring.
Chatterjee, M; Ge, X; Kostov, Y; Luu, P; Tolosa, L; Woo, H; Viscardi, R; Falk, S; Potts, R; Rao, G
2015-05-01
The pain and risk of infection associated with invasive blood sampling for blood gas measurements necessitate the search for reliable noninvasive techniques. In this work we developed a novel rate-based noninvasive method for a safe and fast assessment of respiratory status. A small sampler was built to collect the gases diffusing out of the skin. It was connected to a CO2 sensor through gas-impermeable tubing. During a measurement, the CO2 initially present in the sampler was first removed by purging it with nitrogen. The gases in the system were then recirculated between the sampler and the CO2 sensor, and the CO2 diffusion rate into the sampler was measured. Because the measurement is based on the initial transcutaneous diffusion rate, reaching mass transfer equilibrium and heating the skin is no longer required, thus, making it much faster and safer than traditional method. A series of designed experiments were performed to analyze the effect of the measurement parameters such as sampler size, measurement location, subject positions, and movement. After the factor analysis tests, the prototype was sent to a level IV NICU for clinical trial. The results show that the measured initial rate of increase in CO2 partial pressure is linearly correlated with the corresponding arterial blood gas measurements. The new approach can be used as a trending tool, making frequent blood sampling unnecessary for respiratory status monitoring.
Understanding the physiology of mindfulness: aortic hemodynamics and heart rate variability.
May, Ross W; Bamber, Mandy; Seibert, Gregory S; Sanchez-Gonzalez, Marcos A; Leonard, Joseph T; Salsbury, Rebecca A; Fincham, Frank D
2016-01-01
Data were collected to examine autonomic and hemodynamic cardiovascular modulation underlying mindfulness from two independent samples. An initial sample (N = 185) underwent laboratory assessments of central aortic blood pressure and myocardial functioning to investigated the association between mindfulness and cardiac functioning. Controlling for religiosity, mindfulness demonstrated a strong negative relationship with myocardial oxygen consumption and left ventricular work but not heart rate or blood pressure. A second sample (N = 124) underwent a brief (15 min) mindfulness inducing intervention to examine the influence of mindfulness on cardiovascular autonomic modulation via blood pressure variability and heart rate variability. The intervention had a strong positive effect on cardiovascular modulation by decreasing cardiac sympathovagal tone, vasomotor tone, vascular resistance and ventricular workload. This research establishes a link between mindfulness and cardiovascular functioning via correlational and experimental methodologies in samples of mostly female undergraduates. Future directions for research are outlined.
Automated Microorganism Detector
NASA Astrophysics Data System (ADS)
Keahey, Pelham; Hardy, Will; Cradit, Mason; Solis, Steven; Holland, Andrea; Wade, Gerry
2010-10-01
The detection and identification of bacteria in blood samples is crucial for treating patients suspected of having a blood infection. Current hospital methods for pathogen detection are time-consuming processes with multiple steps. This project's goal was to develop an efficient biomedical device to detect bacterial growth in blood samples, based on Gerald J. Wade's 1979 invention (US patents 4250266 and 4267276). Detection was accomplished using a system of electronics to examine the change in the electrochemical properties of a sample in response to bacterial growth, by measuring the sample's electrical charging and charge dispersion characteristics. After initial trials, it was found that a sample yielded consistent voltage measurements of approximately 200 millivolts prior to any detectable microbial growth. The first species tested, Escherichia coli (E. coli), was detected 11.7 hours after its inoculation in a culture bottle at a concentration of approximately 5-10 organisms per milliliter. In future tests, it is expected that detection times will vary in proportion to the growth rate of each species.
Tarai, B; Das, P; Kumar, D; Budhiraja, S
2012-01-01
Paired blood culture (PBC) is uncommon practice in hospitals in India, leading to delayed and inadequate diagnosis. Also contamination remains a critical determinant in hampering the definitive diagnosis. To establish the need of PBC over single blood culture (SBC) along with the degree of contamination, this comparative retrospective study was initiated. We processed 2553 PBC and 4350 SBC in BacT/ALERT 3D (bioMerieux) between October 2010 and June 2011. The positive cultures were identified in VITEK 2 Compact (bioMerieux). True positivity and contaminants were also analyzed in 486 samples received from catheter and peripheral line. Out of 2553 PBC samples, positivity was seen in 350 (13.70%). In 4350 SBC samples, positivity was seen in 200 samples (4.59%). In PBC true pathogens were 267 (10.45%) and contaminants were 83 (3.25%), whereas in SBC 153 (3.51%) were true positives and contaminants were 47 (1.08%). Most of the blood cultures (99.27 %) grew within 72 h and 95.8% were isolated within 48 h. In 486 PBCs received from catheter/periphery (one each), catheter positivity was found in 85 (true positives were 48, false positives 37). In peripheral samples true positives were 50 and false positives were 8. Significantly higher positive rates were seen in PBCs compared with SBCs. Automated blood culture and identification methods significantly reduced the time required for processing of samples and also facilitated yield of diverse/rare organisms. Blood culture from catheter line had higher false positives than peripheral blood culture. Thus every positive result from a catheter must be correlated with clinical findings and requires further confirmation.
Ferreira, L; Sánchez-Juanes, F; Muñoz-Bellido, J L; González-Buitrago, J M
2011-07-01
Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is a fast and reliable technology for the identification of microorganisms with proteomics approaches. Here, we compare an intact cell method and a protein extraction method before application on the MALDI plate for the direct identification of microorganisms in both urine and blood culture samples from clinical microbiology laboratories. The results show that the intact cell method provides excellent results for urine and is a good initial method for blood cultures. The extraction method complements the intact cell method, improving microorganism identification from blood culture. Thus, we consider that MALDI-TOF MS performed directly on urine and blood culture samples, with the protocols that we propose, is a suitable technique for microorganism identification, as compared with the routine methods used in the clinical microbiology laboratory. © 2010 The Authors. Clinical Microbiology and Infection © 2010 European Society of Clinical Microbiology and Infectious Diseases.
Printed microfluidic filter for heparinized blood.
Bilatto, Stanley E R; Adly, Nouran Y; Correa, Daniel S; Wolfrum, Bernhard; Offenhäusser, Andreas; Yakushenko, Alexey
2017-05-01
A simple lab-on-a-chip method for blood plasma separation was developed by combining stereolithographic 3D printing with inkjet printing, creating a completely sealed microfluidic device. In some approaches, one dilutes the blood sample before separation, reducing the concentration of a target analyte and increasing a contamination risk. In this work, a single drop (8 μ l) of heparinized whole blood could be efficiently filtered using a capillary effect without any external driving forces and without dilution. The blood storage in heparin tubes during 24 h at 4 °C initiated the formation of small crystals that formed auto-filtration structures in the sample upon entering the 3D-printed device, with pores smaller than the red blood cells, separating plasma from the cellular content. The total filtration process took less than 10 s. The presented printed plasma filtration microfluidics fabricated with a rapid prototyping approach is a miniaturized, fast and easy-to-operate device that can be integrated into healthcare/portable systems for point-of-care diagnostics.
Simplifications in analyzing positron emission tomography data: effects on outcome measures.
Logan, Jean; Alexoff, David; Kriplani, Aarti
2007-10-01
Initial validation studies of new radiotracers generally involve kinetic models that require a measured arterial input function. This allows for the separation of tissue binding from delivery and blood flow effects. However, when using a tracer in a clinical setting, it is necessary to eliminate arterial blood sampling due to its invasiveness and the extra burden of counting and analyzing the blood samples for metabolites. In some cases, it may also be necessary to replace dynamic scanning with a shortened scanning period some time after tracer injection, as is done with FDG (F-18 fluorodeoxyglucose). These approximations represent loss of information. In this work, we considered several questions related to this: (1) Do differences in experimental conditions (drug treatments) or populations affect the input function, and what effect, if any, does this have on the final outcome measure? (2) How do errors in metabolite measurements enter into results? (3) What errors are incurred if the uptake ratio is used in place of the distribution volume ratio? (4) Is one- or two-point blood sampling any better for FDG data than the standardized uptake value? and (5) If blood sampling is necessary, what alternatives are there to arterial blood sampling? The first three questions were considered in terms of data from human dynamic positron emission tomography (PET) studies under conditions of baseline and drug pretreatment. Data from [11C]raclopride studies and those from the norepinephrine transporter tracer (S,S)-[11C]O-methyl reboxetine were used. Calculation of a metabolic rate for FDG using the operational equation requires a measured input function. We tested a procedure based on two blood samples to estimate the plasma integral and convolution that occur in the operational equation. There are some tracers for which blood sampling is necessary. Strategies for brain studies involve using the internal carotids in estimating the radioactivity after correcting for partial volume and spillover in order to eliminate arterial sampling. Some venous blood samples are still required for metabolite measurements. The ultimate solution to the problem of arterial sampling may be a wrist scanner, which acts as a small PET camera for imaging the arteries in the wrist. This is currently under development.
Rudel, Ruthann A; Seryak, Liesel M; Brody, Julia G
2008-01-01
Background Polychlorinated biphenyls (PCBs) are persistent pollutants identified worldwide as human blood and breast milk contaminants. Because they bioaccumulate, consumption of meat, fish, and dairy products predicts human blood concentrations. PCBs were also used widely in building materials, including caulks and paints, but few studies have evaluated the contribution of these exposures to body burden. Methods In an earlier study, we detected PCBs in indoor air in 31% of 120 homes on Cape Cod, MA. Two of the homes had much higher concentrations than the rest, so we retested to verify the initial finding, evaluate blood PCB concentrations of residents, and identify the PCB source. Results Air and dust concentrations remained elevated over 5 years between initial and follow-up sampling. Blood serum concentrations of PCBs in residents of the homes were generally elevated above the 95th percentile of a representative sample of the US population. Serum concentrations in residents and air and dust concentrations were especially high in a home where a resident reported use of PCB-containing floor finish in the past, and where the floor of one room was sanded and refinished just prior to sample collection. Conclusion This case-study suggests that PCB residues in homes may be more significant contributors to overall exposure than diet for some people, and that use of a commercially-available PCB-containing wood floor finish in residences during the 1950s and 1960s is an overlooked but potentially important source of current PCB exposure in the general population. PMID:18201376
Association of ABO and Rh Blood Groups to Blood-Borne Infections among Blood Donors in Tehran-Iran
MOHAMMADALI, Fatemeh; POURFATHOLLAH, Aliakbar
2014-01-01
Abstract Background The aim of this study was to investigate the prevalence of hepatitis B, hepatitis C, HIV and syphilis infections in blood donors referred to Tehran Blood Transfusion Center (TBTC), and determine any association between blood groups and blood- borne infections between the years of 2005 and 2011. Methods This was a retrospective study conducted at TBTC. All of the donor serum samples were screened for HBV, HCV, HIV and syphilis by using third generation ELISA kits and RPR test. Initial reactive samples were tested in duplicate. Confirmatory tests were performed on all repeatedly reactive donations. Blood group was determined by forward and reverse blood grouping. The results were subjected to chi square analysis for determination of statistical difference between the values among different categories according to SPSS program. Results Overall, 2031451 donor serum samples were collected in 2005-2011. Totally, 10451 were positive test for HBV, HCV, HIV and syphilis. The overall seroprevalence of HBV, HCV, HIV, and syphilis was 0.39%, 0.11%, 0.005%, and 0.010%, respectively. Hepatitis B and HIV infections were significantly associated with blood group of donors (P <0.05) ; percentage of HIV Ag/Ab was higher in donors who had blood group “A” and percentage of HBs Ag was lower in donors who had blood group O. There was no significant association between Hepatitis C and syphilis infections with ABO and Rh blood groups (P>0.05). Conclusion Compared with neighboring countries and the international standards, prevalence of blood-borne infections is relatively low. PMID:25909065
Association of ABO and Rh Blood Groups to Blood-Borne Infections among Blood Donors in Tehran-Iran.
Mohammadali, Fatemeh; Pourfathollah, Aliakbar
2014-07-01
The aim of this study was to investigate the prevalence of hepatitis B, hepatitis C, HIV and syphilis infections in blood donors referred to Tehran Blood Transfusion Center (TBTC), and determine any association between blood groups and blood- borne infections between the years of 2005 and 2011. This was a retrospective study conducted at TBTC. All of the donor serum samples were screened for HBV, HCV, HIV and syphilis by using third generation ELISA kits and RPR test. Initial reactive samples were tested in duplicate. Confirmatory tests were performed on all repeatedly reactive donations. Blood group was determined by forward and reverse blood grouping. The results were subjected to chi square analysis for determination of statistical difference between the values among different categories according to SPSS program. Overall, 2031451 donor serum samples were collected in 2005-2011. Totally, 10451 were positive test for HBV, HCV, HIV and syphilis. The overall seroprevalence of HBV, HCV, HIV, and syphilis was 0.39%, 0.11%, 0.005%, and 0.010%, respectively. Hepatitis B and HIV infections were significantly associated with blood group of donors (P <0.05) ; percentage of HIV Ag/Ab was higher in donors who had blood group "A" and percentage of HBs Ag was lower in donors who had blood group O. There was no significant association between Hepatitis C and syphilis infections with ABO and Rh blood groups (P>0.05). Compared with neighboring countries and the international standards, prevalence of blood-borne infections is relatively low.
Henny, C.J.; Riddle, K.E.; Hulse, C.S.
1985-01-01
A spring concentration of migrating Peregrine Falcons (Falco peregrinus) was first discovered at Padre Island, Texas, in April 1978. The birds were first captured and blood-sampled for monitoring residue burdens and trends in the late 1970' s. Only 29 Peregrines were sampled in 1978 and 1979, but 111 were sampled in 1980. The initial investigation showed that DDE in the plasma of spring migrants returning from Latin America for the first time declined significantly during the study (through 1980). In the spring of 1984, 48 Peregrines were captured at Padre Island with blood samples again collected. This report will compare plasma residue data from the earlier study with residues obtained in 1984.
Microfluidics for simultaneous quantification of platelet adhesion and blood viscosity
Yeom, Eunseop; Park, Jun Hong; Kang, Yang Jun; Lee, Sang Joon
2016-01-01
Platelet functions, including adhesion, activation, and aggregation have an influence on thrombosis and the progression of atherosclerosis. In the present study, a new microfluidic-based method is proposed to estimate platelet adhesion and blood viscosity simultaneously. Blood sample flows into an H-shaped microfluidic device with a peristaltic pump. Since platelet aggregation may be initiated by the compression of rotors inside the peristaltic pump, platelet aggregates may adhere to the H-shaped channel. Through correlation mapping, which visualizes decorrelation of the streaming blood flow, the area of adhered platelets (APlatelet) can be estimated without labeling platelets. The platelet function is estimated by determining the representative index IA·T based on APlatelet and contact time. Blood viscosity is measured by monitoring the flow conditions in the one side channel of the H-shaped device. Based on the relation between interfacial width (W) and pressure ratio of sample flows to the reference, blood sample viscosity (μ) can be estimated by measuring W. Biophysical parameters (IA·T, μ) are compared for normal and diabetic rats using an ex vivo extracorporeal model. This microfluidic-based method can be used for evaluating variations in the platelet adhesion and blood viscosity of animal models with cardiovascular diseases under ex vivo conditions. PMID:27118101
Høiseth, Gudrun; Fjeld, Bente; Burns, Margrete Larsen; Strand, Dag Helge; Vindenes, Vigdis
2014-06-01
Stability of drugs during storage is important in forensic toxicology. For the analytes detected after intake of heroin (6-acetylmorphine (6-AM), morphine and codeine), long-time stability in real life whole blood samples are studied in only a small number of cases. Whole blood post mortem (n=37) and whole blood samples from living persons (n=22) containing morphine and codeine as well as 6-AM in blood or urine were selected. All cases represented intake of heroin. All samples contained fluoride and were initially analysed and stored in normal conditions (-20°C) for 4-9 years. All samples were then reanalysed using the same analytical methods and the results were compared. For samples from living persons, the median change in concentration was -3.7% for morphine and -5.3% for codeine. For post mortem samples, the median change in concentration was -12% for morphine and -11% for codeine. Both for samples from living persons and post mortem samples, the decrease in the concentrations from the original analysis to reanalysis were statistically significant for morphine and codeine. Regarding 6-AM, all living samples were negative at reanalysis. For post mortem samples, four cases still tested positive for 6-AM at reanalysis with a median change in the concentrations of -81%. There was no significant change in the morphine to codeine concentration ratios neither for living nor post mortem samples. This study showed that in real life whole blood samples, the concentrations of morphine and codeine are relatively stable during long-term storage at -20°C. 6-AM on the other hand, shows a considerable decrease in concentrations that is important to consider when interpreting results from reanalyses of forensic cases. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Ameri, Mehrdad; Schnaars, Henry A; Sibley, John R; Honor, David J
2011-06-01
The time from sampling to analysis can be delayed when blood samples are shipped to distant reference laboratories or when analysis cannot be readily performed. The objective of this study was to evaluate the stability of hematologic analytes in blood samples from monkeys, rabbits, rats, and mice when samples were stored for up to 72 hours at 4°C. Blood samples from 30 monkeys, 15 rabbits, 20 rats, and 30 mice were collected into EDTA-containing tubes and were initially analyzed within 1 hour of collection using the ADVIA 120 analyzer. The samples were then stored at 4°C and reanalyzed at 24, 48, and 72 hours after collection. Significant (P<.0003) changes in hematologic analytes and calculations included increased HCT and MCV and decreased MCHC and cell hemoglobin concentration mean (CHCM) at 72 hours and increased MPV at 24 hours in monkeys; increased MCV at 72 hours and MPV at 48 hours and decreased monocyte count at 24 hours in rabbits; increased MCV and decreased MCHC, CHCM, and monocyte count at 24 hours in rats; increased MCV, red cell distribution width, and MPV and decreased MCHC, CHCM, and monocyte count at 24 hours in mice. Although most of the changes in the hematologic analytes in blood from monkeys, rabbits, rats, and mice when samples were stored at 4°C were analytically acceptable and clinically negligible, the best practice in measuring hematologic analytes in these animals is timely processing of blood samples, preferably within 1 hour after collection. ©2011 American Society for Veterinary Clinical Pathology.
The effects of hurricane Rita and subsequent drought on alligators in southwest Louisiana.
Lance, Valentine A; Elsey, Ruth M; Butterstein, George; Trosclair, Phillip L; Merchant, Mark
2010-02-01
Hurricane Rita struck the coast of southwest Louisiana in September 2005. The storm generated an enormous tidal surge of approximately four meters in height that inundated many thousands of acres of the coastal marsh with full strength seawater. The initial surge resulted in the deaths of a number of alligators and severely stressed those who survived. In addition, a prolonged drought (the lowest rainfall in 111 years of recorded weather data) following the hurricane resulted in highly saline conditions that persisted in the marsh for several months. We had the opportunity to collect 11 blood samples from alligators located on Holly Beach less than a month after the hurricane, but were unable to collect samples from alligators on Rockefeller Wildlife Refuge until February 2006. Conditions at Rockefeller Refuge did not permit systematic sampling, but a total of 201 samples were collected on the refuge up through August 2006. The blood samples were analyzed for sodium, potassium, chloride, osmolality, and corticosterone. Blood samples from alligators sampled on Holly Beach in October 2005, showed a marked elevation in plasma osmolality, sodium, chloride, potassium, corticosterone, and an elevated heterophil/lymphocyte ratio. Blood samples from alligators on Rockefeller Refuge showed increasing levels of corticosterone as the drought persisted and elevated osmolality and electrolytes. After substantial rainfall in July and August, these indices of osmotic stress returned to within normal limits. (c) 2009 Wiley-Liss, Inc.
Clement, Ryan S; Unger, Erica L; Ocón-Grove, Olga M; Cronin, Thomas L; Mulvihill, Maureen L
2016-01-01
Blood collection is commonplace in biomedical research. Obtaining sufficient sample while minimizing animal stress requires significant skill and practice. Repeated needle punctures can cause discomfort and lead to variable release of stress hormones, potentially confounding analysis. We designed a handheld device to reduce the force necessary for needle insertion by using low-frequency, axial (forward and backward) micromotions (that is, vibration) delivered to the needle during venipuncture. Tests with cadaver rat-tail segments (n = 18) confirmed that peak insertion forces were reduced by 73% on average with needle vibration. A serial blood-sampling study was then conducted by using Sprague–Dawley rats divided into 2 groups based on needle condition used to cause bleeds: vibration on (n = 10) and vibration off (n = 9). On 3 days (1 wk apart), 3 tail-vein blood collections were performed in each subject at 1-h intervals. To evaluate associated stress levels, plasma corticosterone concentration was quantified by radioimmunoassay and behavior (that is, movement and vocalization) was scored by blinded review of blood-sampling videos. After the initial trial, average corticosterone was lower (46% difference), the mean intrasubject variance trended lower (72%), and behavioral indications of stress were rated lower for the vibration-on group compared with the vibration-off group. Adding controlled vibrations to needles during insertion may decrease the stress associated with blood sampling from rats—an important methodologic advance for investigators studying and assessing stress processes and a refinement over current blood sampling techniques. PMID:27025813
Granat, Fanny; Geffré, Anne; Bourgès-Abella, Nathalie; Braun, Jean-Pierre; Trumel, Catherine
2013-06-01
In veterinary medicine a complete blood cell count (CBC) cannot always be performed within 24 h as usually recommended, particularly for specimens shipped to a reference laboratory. This raises the question of the stability of the variables, especially in ethylenediamine tetra-acetic acid (EDTA) feline blood specimens, known to be prone to in vitro platelet aggregation. Citrate, theophylline, adenosine and dipyridamole (CTAD) has been reported to limit platelet aggregation in feline blood specimens. The aim of this study was to measure the stability of the haematological variables and the platelet aggregation score in EDTA and EDTA plus CTAD (EDCT) feline blood specimens during 48 h of storage at room temperature. Forty-six feline EDTA and EDCT blood specimens were analysed with a Sysmex XT-2000iV analyser, and the platelet count and score of platelet aggregation were estimated immediately and after 24 and 48 h of storage. A significant increase in mean corpuscular volume, haematocrit, reticulocyte and eosinophil counts, and a significant decrease in mean corpuscular haemoglobin concentration and monocyte count were observed. Haemoglobin, mean corpuscular haemoglobin, and red blood cell, white blood cell, neutrophil and lymphocyte counts remained stable. Changes in reticulocyte indexes with time (low fluorescence ratio, medium fluorescence ratio, high fluorescence ratio and immature reticulocyte fraction) were not significant. Changes were generally more pronounced in EDTA than in EDCT. Platelet aggregation decreased markedly in initially highly aggregated EDTA specimens, and increased slightly in initially non- or mildly-aggregated EDTA or EDCT specimens. Platelet counts increased and decreased, or remained stable, respectively. CTAD can reduce storage-induced changes of the haematological variables in feline samples, thus improving the reliability of a CBC and limiting clinical misinterpretations.
Gatica, M C; Monti, G E; Knowles, T G; Gallo, C B
2010-01-09
Two systems for transporting live salmon (Salmo salar) were compared in terms of their effects on blood variables, muscle pH and rigor index: an 'open system' well-boat with recirculated sea water at 13.5 degrees C and a stocking density of 107 kg/m3 during an eight-hour journey, and a 'closed system' well-boat with water chilled from 16.7 to 2.1 degrees C and a stocking density of 243.7 kg/m3 during a seven-hour journey. Groups of 10 fish were sampled at each of four stages: in cages at the farm, in the well-boat after loading, in the well-boat after the journey and before unloading, and in the processing plant after they were pumped from the resting cages. At each sampling, the fish were stunned and bled by gill cutting. Blood samples were taken to measure lactate, osmolality, chloride, sodium, cortisol and glucose, and their muscle pH and rigor index were measured at death and three hours later. In the open system well-boat, the initial muscle pH of the fish decreased at each successive stage, and at the final stage they had a significantly lower initial muscle pH and more rapid onset of rigor than the fish transported on the closed system well-boat. At the final stage all the blood variables except glucose were significantly affected in the fish transported on both types of well-boat.
Hyperpolarized (129)Xe T (1) in oxygenated and deoxygenated blood
NASA Technical Reports Server (NTRS)
Albert, M. S.; Balamore, D.; Kacher, D. F.; Venkatesh, A. K.; Jolesz, F. A.
2000-01-01
The viability of the new technique of hyperpolarized (129)Xe MRI (HypX-MRI) for imaging organs other than the lungs depends on whether the spin-lattice relaxation time, T(1), of (129)Xe is sufficiently long in the blood. In previous experiments by the authors, the T(1) was found to be strongly dependent upon the oxygenation of the blood, with T(1) increasing from about 3 s in deoxygenated samples to about 10 s in oxygenated samples. Contrarily, Tseng et al. (J. Magn. Reson. 1997; 126: 79-86) reported extremely long T(1) values deduced from an indirect experiment in which hyperpolarized (129)Xe was used to create a 'blood-foam'. They found that oxygenation decreased T(1). Pivotal to their experiment is the continual and rapid exchange of hyperpolarized (129)Xe between the gas phase (within blood-foam bubbles) and the dissolved phase (in the skin of the bubbles); this necessitated a complicated analysis to extract the T(1) of (129)Xe in blood. In the present study, the experimental design minimizes gas exchange after the initial bolus of hyperpolarized (129)Xe has been bubbled through the sample. This study confirms that oxygenation increases the T(1) of (129)Xe in blood, from about 4 s in freshly drawn venous blood, to about 13 s in blood oxygenated to arterial levels, and also shifts the red blood cell resonance to higher frequency. Copyright 2000 John Wiley & Sons, Ltd. Abbreviations used BOLD blood oxygen level dependent NOE nuclear overhouses effect PO(2) oxygen partial pressure RBC red blood cells RF radio frequency SNR signal-to-noise ratio.
Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao
2013-11-21
This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.
VITELLOGENIN-INDUCED PATHOLOGY AND MORTALITY IN MALE SUMMER FLOUNDER (PARALICHTHYS DENTATUS)
Male summer flounder (Paralichthys dentatus) were given two injections (initially and two weeks later) of 17 b-estradiol (E2) totaling 0.2 (2 x 0.1), 2.0 (2 x 1.0) or 20.0 (2 x 10.0) mg E2/kg body weight. Blood and tissue samples were collected 4, 6 and 8 weeks after the initial ...
VITELLOGENIN-INDUCED PATHOLOGY IN MALE SUMMER FLOUNDER (PARALICHTHYS DENTATUS)
Male summer flounder (Paralichthys dentatus) were given two injections (initially and 2 weeks later) of 17 -estra-diol (E2) totaling 0.2 (2 x 0.1), 2.0 (2 x 1.0) or 20.0 (2 x 10.0) mg E2/kg body weight. Blood and tissue samples were collected 4, 6 and 8 weeks after the initial in...
Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S
2014-09-15
Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test for antibodies in the ICT and compared to ICT results using thawed plasma (same initial source). Sensitivity and specificity of the ICT using DBS were determined by using ICT results from traditional blood collection samples for comparison. After 1 month, DBS samples showed 100% sensitivity and specificity when compared to ICT results on thawed plasma samples collected by traditional venipuncture. After six months storage at room temperature, DBS samples demonstrated 79% sensitivity and 100% specificity compared to traditional blood collection. Results from this study indicate that dried blood spot collection may be a useful tool for screening dogs for antibodies to L. infantum with the ICT assay. Copyright © 2014 Elsevier B.V. All rights reserved.
The blood donor identity survey: a multidimensional measure of blood donor motivations.
France, Christopher R; Kowalsky, Jennifer M; France, Janis L; Himawan, Lina K; Kessler, Debra A; Shaz, Beth H
2014-08-01
Evidence indicates that donor identity is an important predictor of donation behavior; however, prior studies have relied on diverse, unidimensional measures with limited psychometric support. The goals of this study were to examine the application of self-determination theory to blood donor motivations and to develop and validate a related multidimensional measure of donor identity. Items were developed and administered electronically to a sample of New York Blood Center (NYBC) donors (n=582) and then to a sample of Ohio University students (n=1005). Following initial confirmatory factor analysis (CFA) on the NYBC sample to identify key items related to self-determination theory's six motivational factors, a revised survey was administered to the university sample to reexamine model fit and to assess survey reliability and validity. Consistent with self-determination theory, for both samples CFAs indicated that the best fit to the data was provided by a six-motivational-factor model, including amotivation, external regulation, introjected regulation, identified regulation, integrated regulation, and intrinsic regulation. The Blood Donor Identity Survey provides a psychometrically sound, multidimensional measure of donor motivations (ranging from unmotivated to donate to increasing levels of autonomous motivation to donate) that is suitable for nondonors as well as donors with varying levels of experience. Future research is needed to examine longitudinal changes in donor identity and its relationship to actual donation behavior. © 2014 AABB.
Seminal HIV-1 RNA Detection in Heterosexual African Men Initiating Antiretroviral Therapy.
Mujugira, Andrew; Coombs, Robert W; Heffron, Renee; Celum, Connie; Ronald, Allan; Mugo, Nelly; Baeten, Jared M
2016-07-15
Intermittent shedding of human immunodeficiency virus type 1 (HIV) in semen occurs despite effective antiretroviral therapy (ART) and suppressed blood HIV-1 RNA levels. We assessed the frequency, magnitude, and correlates of seminal HIV-1 RNA shedding in HIV-1-infected African men initiating ART. Seminal HIV-1 RNA was detected in 24% (37 of 155), 10% (5 of 49), and 11% (8 of 70) of samples collected 0-3, 4-6, and >6 months after ART initiation. When blood HIV-1 levels were suppressed, seminal HIV-1 RNA was detected in 8% (16 of 195), and 82% (13 of 16) had an HIV-1 RNA load of < 1000 copies/mL. Seminal HIV-1 RNA shedding was infrequent and present at low levels in HIV-1-infected African men with suppressed blood HIV-1 RNA. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Bou, Germán; Figueroa, Marta S.; Martí-Belda, Paloma; Navas, Enrique; Guerrero, Antonio
1999-01-01
Toxoplasma gondii infection is an important cause of chorioretinitis in the United States and Europe. Most cases of Toxoplasma chorioretinitis result from congenital infection. Patients are often asymptomatic during life, with a peak incidence of symptomatic illness in the second and third decades of life. Diagnosis is mainly supported by ophthalmological examination and a good response to installed therapy. However, establishment of a diagnosis by ophthalmological examination alone can be difficult in some cases. To determine the diagnostic value of PCR for the detection of T. gondii, 56 blood and 56 aqueous humor samples from 56 immunocompetent patients were examined. Fifteen patients with a diagnosis of ocular toxoplasmosis had increased serum anti-T. gondii immunoglobulin G levels but were negative for anti-T. gondii immunoglobulin M (group 1), and 41 patients were used as controls (group 2). Samples were taken before antiparasitic therapy was initiated, and only one blood sample and one aqueous humor sample were obtained for each patient. Single nested PCRs and Southern blot hybridization were performed with DNA extracted from these samples. The results obtained showed sensitivity and specificity values of 53.3 and 83%, respectively. Interestingly, among all patients with ocular toxoplasmosis, a positive PCR result with the aqueous humor sample was accompanied by a positive PCR result with the blood sample. This result suggests that ocular toxoplasmosis should not be considered a local event, as PCR testing of blood samples from patients with ocular toxoplasmosis yielded the same result as PCR testing of aqueous humor samples. PCR testing may be useful for discriminating between ocular toxoplasmosis and other ocular diseases, and also can avoid the problems associated with ocular puncture. PMID:10523535
Cutpoints for screening blood glucose concentrations in healthy senior cats.
Reeve-Johnson, Mia K; Rand, Jacquie S; Vankan, Dianne; Anderson, Stephen T; Marshall, Rhett; Morton, John M
2017-12-01
Objectives The objectives of this study were to determine the reference interval for screening blood glucose in senior cats, to apply this to a population of obese senior cats, to compare screening and fasting blood glucose, to assess whether screening blood glucose is predicted by breed, body weight, body condition score (BCS), behaviour score, fasting blood glucose and/or recent carbohydrate intake and to assess its robustness to changes in methodology. Methods The study included a total of 120 clinically healthy client-owned cats aged 8 years and older of varying breeds and BCSs. Blood glucose was measured at the beginning of the consultation from an ear/paw sample using a portable glucose meter calibrated for cats, and again after physical examination from a jugular sample. Fasting blood glucose was measured after overnight hospitalisation and fasting for 18-24 h. Results The reference interval upper limit for screening blood glucose was 189 mg/dl (10.5 mmol/l). Mean screening blood glucose was greater than mean fasting glucose. Breed, body weight, BCS, behaviour score, fasting blood glucose concentration and amount of carbohydrate consumed 2-24 h before sampling collectively explained only a small proportion of the variability in screening blood glucose. Conclusions and relevance Screening blood glucose measurement represents a simple test, and cats with values from 117-189 mg/dl (6.5-10.5 mmol/l) should be retested several hours later. Cats with initial screening blood glucose >189 mg/dl (10.5 mmol/l), or a second screening blood glucose >116 mg/dl (6.4 mmol/l) several hours after the first, should have fasting glucose and glucose tolerance measured after overnight hospitalisation.
Effect of solvent/detergent-treated pooled plasma on fibrinolysis in reconstituted whole blood.
Saadah, Nicholas H; van der Meer, Pieter F; Brinkman, Herm Jan M; de Korte, Dirk; Bontekoe, Ido J; Korsten, Herbert H; Middelburg, Rutger A; van der Bom, Johanna G; Schipperus, Martin R
2017-10-01
Hyperfibrinolysis has been observed in patients heavily transfused with solvent/detergent-treated pooled plasma (S/D plasma). We compared coagulation and fibrinolytic variables in blood containing S/D plasma with blood containing fresh-frozen plasma (FFP), with and without α2-antiplasmin or tranexamic acid (TXA) supplementation. Whole blood samples were reconstituted from red blood cells, platelet (PLT) concentrates, and varying mixtures of FFP and S/D plasma. Hematocrit and PLT count of reconstituted whole blood samples were varied. For a subset of runs, α2-antiplasmin or TXA was added to S/D plasma whole blood samples. Thromboelastography (TEG) analysis was performed to assess 50% clot lysis time (CLT 50% ), maximum amplitude (MA), and initial clotting time (R-time). The change in CLT 50% of whole blood as the plasma compartment transitions from FFP to S/D plasma was -52% (95% confidence interval [CI], -60% to -45%; p < 0.001). PLT count strengthened the effect, leading to an additional change in CLT 50% of -8% (95% CI, -14% to -2%; p = 0.012) as PLT count increased from 10 × 10 9 to 150 × 10 9 /L. MA and R-time were not associated with fraction of S/D plasma in whole blood. α2-Antiplasmin and TXA restored clot lysis time in S/D plasma whole blood. Whole blood with S/D plasma has shorter clot lysis times in vitro compared to whole blood with FFP. α2-Antiplasmin and TXA restore clot lysis time of S/D plasma whole blood to that of FFP whole blood. Clinicians should be aware of the decreased clot lysis time associated with S/D plasma transfusion. © 2017 AABB.
Zalesskaya, G A
2015-01-01
The effect of in vivo laser irradiation by optical radiation on blood from different patients is studied. The objects of research were three series of blood samples from patients whose treatment course included extracorporeal UV blood irradiation, intravenous laser blood irradiation and supra-venous blood laser irradiation. Before and after irradiation the results on optic oximetry and gas content of venous blood were compared. The results of positive and negative influence of blood irradiation on characteristics of an oxygen exchange in separate patients and on the maintenance of some products of metabolism are represented. It is shown that at the same power dose, their changes depend on individual, initial values of hemoglobin oxygen saturation of venous blood and its photoinduced changes which objectively reflect individual sensitivity of patients to the action of optical radiation on blood and can be used for assessment of the efficiency of phototherapy.
Madsen, Lene H; Christensen, Geir; Lund, Terje; Serebruany, Victor L; Granger, Chris B; Hoen, Ingvild; Grieg, Zanina; Alexander, John H; Jaffe, Allan S; Van Eyk, Jennifer E; Atar, Dan
2006-11-10
Although measurement of troponin is widely used for diagnosing acute myocardial infarction (AMI), its diagnostic potential may be increased by a more complete characterization of its molecular appearance and degradation in the blood. The aim of this study was to define the time course of cardiac troponin I (cTnI) degradation in patients with acute ST-elevation myocardial infarction (STEMI). In the ASSENT-2 substudy, 26 males hospitalized with STEMI were randomized to 2 different thrombolytic drugs within 6 hours after onset of symptoms. Blood samples were obtained just before initiation of thrombolysis and at 30 minutes intervals (7 samples per patient). Western blot analysis was performed using anti-cTnI antibodies and compared with serum concentrations of cTnI. All patients exceeded the cTnI cutoff for AMI during the sampling period; at initiation of therapy, 23 had elevated cTnI values. All patients demonstrated 2 bands on immunoblot: intact cTnI and a single degradation product as early as 90 minutes after onset of symptoms. On subsequent samples, 15 of 26 patients showed multiple degradation products with up to 7 degradation bands. The appearance of fragments was correlated with higher levels of cTnI (P<0.001) and time to initiation of treatment (P=0.058). This study defines for the first time the initial time course of cTnI degradation in STEMI. Intact cTnI and a single degradation product were detectable on immunoblot as early as 90 minutes after onset of symptoms with further degradation after 165 minutes. Infarct size and time to initiation of treatment was the major determinant for degradation.
Petrini, Stefano; Pierini, Ilaria; Giammarioli, Monica; Feliziani, Francesco; De Mia, Gian Mario
2017-03-01
We evaluated the use of oral fluid as an alternative to serum samples for Classical swine fever virus (CSFV) detection. Individual oral fluid and serum samples were collected at different times post-infection from pigs that were experimentally inoculated with CSFV Alfort 187 strain. We found no evidence of CSFV neutralizing antibodies in swine oral fluid samples under our experimental conditions. In contrast, real-time reverse transcription-polymerase chain reaction could detect CSFV nucleic acid from the oral fluid as early as 8 d postinfection, which also coincided with the time of initial detection in blood samples. The probability of CSFV detection in oral fluid was identical or even higher than in the corresponding blood sample. Our results support the feasibility of using this sampling method for CSFV genome detection, which may represent an additional cost-effective tool for CSF control.
Detection of Streptococcus mutans Genomic DNA in Human DNA Samples Extracted from Saliva and Blood
Vieira, Alexandre R.; Deeley, Kathleen B.; Callahan, Nicholas F.; Noel, Jacqueline B.; Anjomshoaa, Ida; Carricato, Wendy M.; Schulhof, Louise P.; DeSensi, Rebecca S.; Gandhi, Pooja; Resick, Judith M.; Brandon, Carla A.; Rozhon, Christopher; Patir, Asli; Yildirim, Mine; Poletta, Fernando A.; Mereb, Juan C.; Letra, Ariadne; Menezes, Renato; Wendell, Steven; Lopez-Camelo, Jorge S.; Castilla, Eduardo E.; Orioli, Iêda M.; Seymen, Figen; Weyant, Robert J.; Crout, Richard; McNeil, Daniel W.; Modesto, Adriana; Marazita, Mary L.
2011-01-01
Caries is a multifactorial disease, and studies aiming to unravel the factors modulating its etiology must consider all known predisposing factors. One major factor is bacterial colonization, and Streptococcus mutans is the main microorganism associated with the initiation of the disease. In our studies, we have access to DNA samples extracted from human saliva and blood. In this report, we tested a real-time PCR assay developed to detect copies of genomic DNA from Streptococcus mutans in 1,424 DNA samples from humans. Our results suggest that we can determine the presence of genomic DNA copies of Streptococcus mutans in both DNA samples from caries-free and caries-affected individuals. However, we were not able to detect the presence of genomic DNA copies of Streptococcus mutans in any DNA samples extracted from peripheral blood, which suggests the assay may not be sensitive enough for this goal. Values of the threshold cycle of the real-time PCR reaction correlate with higher levels of caries experience in children, but this correlation could not be detected for adults. PMID:21731912
Extensive monitoring through multiple blood samples in professional soccer players.
Heisterberg, Mette F; Fahrenkrug, Jan; Krustrup, Peter; Storskov, Anders; Kjær, Michael; Andersen, Jesper L
2013-05-01
The aim of this study was to make a comprehensive gathering of consecutive detailed blood samples from professional soccer players and to analyze different blood parameters in relation to seasonal changes in training and match exposure. Blood samples were collected 5 times during a 6-month period and analyzed for 37 variables in 27 professional soccer players from the best Danish league. Additionally, the players were tested for body composition, V[Combining Dot Above]O2max and physical performance by the Yo-Yo intermittent endurance submax test (IE2). Multiple variations in blood parameters occurred during the observation period, including a decrease in hemoglobin and an increase in hematocrit as the competitive season progressed. Iron and transferrin were stable, whereas ferritin showed a decrease at the end of the season. The immunoglobulin A (IgA) and IgM increased in the period with basal physical training and at the end of the season. Leucocytes decreased with increased physical training. Lymphocytes decreased at the end of the season. The V[Combining Dot Above]O2max decreased toward the end of the season, whereas no significant changes were observed in the IE2 test. The regular blood samples from elite soccer players reveal significant changes that may be related to changes in training pattern, match exposure, or length of the match season. Especially the end of the preparation season and at the end of the competitive season seem to be time points were the blood-derived values indicate that the players are under excessive physical strain and might be more subjected to a possible overreaching-overtraining conditions. We suggest that regular analyses of blood samples could be an important initiative to optimize training adaptation, training load, and game participation, but sampling has to be regular, and a database has to be built for each individual player.
Li, Chung-Chen; Beck, Ingrid A; Seidel, Kristy D; Frenkel, Lisa M
2004-08-01
The stability of human immunodeficiency virus type 1 (HIV-1) DNA in whole blood collected on filter paper (FTA Card) was evaluated. After >4 years of storage at room temperature in the dark our qualitative assay detected virus at a rate similar to that of our initial test (58 of 60, 97%; P = 0.16), suggesting long-term HIV-1 DNA stability.
Li, Chung-Chen; Beck, Ingrid A.; Seidel, Kristy D.; Frenkel, Lisa M.
2004-01-01
The stability of human immunodeficiency virus type 1 (HIV-1) DNA in whole blood collected on filter paper (FTA Card) was evaluated. After >4 years of storage at room temperature in the dark our qualitative assay detected virus at a rate similar to that of our initial test (58 of 60, 97%; P = 0.16), suggesting long-term HIV-1 DNA stability. PMID:15297546
Examination of the health status of populations from depleted-uranium-contaminated regions.
Milacić, Snezana; Petrović, Dragana; Jovicić, Dubravka; Kovacević, Radomir; Simić, Jadranko
2004-05-01
During the NATO air strikes on the Federal Republic of Yugoslavia (Serbia and Montenegro) in 1999, depleted-uranium ammunition was used on 112 locations, mainly Kosovo, in the south of Serbia, and one location in Montenegro. Blood samples of residents from depleted-uranium-contaminated areas were gathered and blood cell and chromosomal aberrations were analyzed. During the last 3 years blood samples from 21 residents of Kosovo (Strpce), from 29 residents from the south of Serbia (the Vranje and Bujanovac regions), and from 19 technical television workers from the site of Pljackovica, in the vicinity of Vranje, were collected. Blood samples from 33 residents of central Serbia and 46 occupational workers exposed to X-rays were used as controls. All subjects studied were without any clinical symptoms of disease. The examinations included general clinical assessment; urine samples for alpha-and gamma-spectrometry analysis; complete blood counts; ratio-percentages of blood cells in stained (Giemsa) capillary smears, individual leukocyte line elements; morphological changes observed under a microscope; the presence of immature forms or blasts; and leukocyte enzyme activity [alkaline phosphatase leukocyte (APL)]. Chromosomal aberrations were evaluated in 200 peripheral blood lymphocytes in mitosis. An increased incidence of rogue cells and chromosomal aberrations was found in the blood of the residents of Vranje and Bujanovac, but this was below the incidence of chromosomal aberrations in individuals occupationally exposed to ionizing irradiation. Blast cells were not found. Blood counts were decreased in only a few samples, while morphological changes of both nuclei and cytoplasm were marked in individuals in south and central Serbia. Enzymatic activity (as measured by the APL score) was decreased in samples with chromosomal aberrations and cyto-morphological changes in subjects from the south of Serbia. The contamination level measured by this examination was low. Because of the presence of depleted uranium (uranium-238) in the soil and in plants, the prevention of consequences necessitates the identification of the initial biological effects on sensitive tissues. Early identification of serious blood cell changes is important for appropriate medical treatment.
NASA Astrophysics Data System (ADS)
Zalesskaya, G. A.; Laskina, O. V.
2016-03-01
For three series of blood samples, we have studied the effect of therapeutic doses of low-intensity optical radiation (LOR) on oxygenation parameters of blood irradiated in vivo, and also on the levels of some metabolites: lactate, glucose, cholesterol. The quality of blood oxygenation was assessed using three parameters: the partial pressure of oxygen pVO2, the oxygen saturation of hemoglobin SVO2, and the oxygen level in arterial and venous blood, varying under the influence of low-intensity optical radiation due to photodissociation of hemoglobin/ligand complexes. We have established that during photohemotherapy (PHT), including extracorporeal, supravascular, and intravenous blood irradiation, positive changes occur in the oxygenation parameters and the metabolite levels, while after the courses of PHT have been completed, the individual changes in such parameters in individual patients were both positive and negative. The regulatory effect of PHT was apparent in the tendency toward a decrease in high initial values and an increase in low initial values both for the oxygenation parameters and for the metabolites; but at the doses recommended for use, PHT had a regulatory but still not a normalizing effect.
Fluorescence spectra of blood plasma treated with ultraviolet irradiation in vivo
NASA Astrophysics Data System (ADS)
Zalesskaya, G. A.; Maslova, T. O.
2010-09-01
We have studied the fluorescence spectra of blood plasma from patients with acute coronary syndrome, and also the effect of therapeutic doses of in vivo ultraviolet blood irradiation (UBI) on the spectra. We have established that the maxima in the fluorescence spectra of the original plasma samples, obtained from unirradiated blood, are located in the wavelength interval 330-340 nm, characteristic for the fluorescence of tryptophan residues. In extracorporeal UBI ( λ = 254 nm), we observed changes in the shape and also both a blue and a red shift in the maxima of the fluorescence spectra, differing in magnitude for blood plasma samples from different patients in the test group. We show that UBI-initiated changes in the fluorescence spectra of the plasma depend on the original pathological disturbances of metabolite levels, and also on the change in the oxygen-transport function of the blood and the acid-base balance, affecting the oxidative stability of the plasma. We have concluded that UV irradiation, activating buffer systems in the blood, has an effect on the universal and specific interactions of the tryptophan residue with the amino acid residues and water surrounding it.
Detection of human disease conditions by single-cell morpho-rheological phenotyping of blood.
Toepfner, Nicole; Herold, Christoph; Otto, Oliver; Rosendahl, Philipp; Jacobi, Angela; Kräter, Martin; Stächele, Julia; Menschner, Leonhard; Herbig, Maik; Ciuffreda, Laura; Ranford-Cartwright, Lisa; Grzybek, Michal; Coskun, Ünal; Reithuber, Elisabeth; Garriss, Geneviève; Mellroth, Peter; Henriques-Normark, Birgitta; Tregay, Nicola; Suttorp, Meinolf; Bornhäuser, Martin; Chilvers, Edwin R; Berner, Reinhard; Guck, Jochen
2018-01-13
Blood is arguably the most important bodily fluid and its analysis provides crucial health status information. A first routine measure to narrow down diagnosis in clinical practice is the differential blood count, determining the frequency of all major blood cells. What is lacking to advance initial blood diagnostics is an unbiased and quick functional assessment of blood that can narrow down the diagnosis and generate specific hypotheses. To address this need, we introduce the continuous, cell-by-cell morpho-rheological (MORE) analysis of diluted whole blood, without labeling, enrichment or separation, at rates of 1000 cells/sec. In a drop of blood we can identify all major blood cells and characterize their pathological changes in several disease conditions in vitro and in patient samples. This approach takes previous results of mechanical studies on specifically isolated blood cells to the level of application directly in blood and adds a functional dimension to conventional blood analysis. © 2018, Toepfner et al.
Detection of human disease conditions by single-cell morpho-rheological phenotyping of blood
Toepfner, Nicole; Herold, Christoph; Otto, Oliver; Rosendahl, Philipp; Jacobi, Angela; Kräter, Martin; Stächele, Julia; Menschner, Leonhard; Herbig, Maik; Ciuffreda, Laura; Ranford-Cartwright, Lisa; Grzybek, Michal; Coskun, Ünal; Reithuber, Elisabeth; Garriss, Geneviève; Mellroth, Peter; Henriques-Normark, Birgitta; Tregay, Nicola; Suttorp, Meinolf; Bornhäuser, Martin; Chilvers, Edwin R; Berner, Reinhard
2018-01-01
Blood is arguably the most important bodily fluid and its analysis provides crucial health status information. A first routine measure to narrow down diagnosis in clinical practice is the differential blood count, determining the frequency of all major blood cells. What is lacking to advance initial blood diagnostics is an unbiased and quick functional assessment of blood that can narrow down the diagnosis and generate specific hypotheses. To address this need, we introduce the continuous, cell-by-cell morpho-rheological (MORE) analysis of diluted whole blood, without labeling, enrichment or separation, at rates of 1000 cells/sec. In a drop of blood we can identify all major blood cells and characterize their pathological changes in several disease conditions in vitro and in patient samples. This approach takes previous results of mechanical studies on specifically isolated blood cells to the level of application directly in blood and adds a functional dimension to conventional blood analysis. PMID:29331015
Niazi, Saifullah Khan; Alam, Maqbool; Yazdani, Muhammad Sajid; Ghani, Eijaz; Rathore, Muhammad Ali
2017-01-01
The study was planned to determine the presence of West Nile Virus (WNV) infection in Pakistani blood donors, using Nucleic Acid Amplification Test (NAT). The blood donors for study were selected on the basis of the standard questionnaire and routine screening results. Six donors were pooled using an automated pipettor and NAT for WNV was performed on Roche Cobas s 201 NAT system. The reactive pools were resolved in Individual Donation-NAT (ID-NAT) format and a sample from FFP bags of reactive donations was retrieved. NAT was again performed on retrieved plasma bag (RPB) sample to confirm the reactive donations. The donors were also recalled and interviewed about history of illness related to recent WNV infection. After serological screening of 1929 donors during the study period, 1860 donors were selected for NAT test for WNV detection. The mean age of the donors was 28±8.77 (range: 18-57 years). 1847 (99.3%) donors were male and 13 (0.7%) were female. NAT for WNV identified six initially reactive pools (0.32%). On follow-up testing with RPB samples, 4 donors (0.21%) were found confirmed reactive for WNV RNA (NAT yield of 1 in 465 blood donors). WNV is a threat to safety of blood products in Pakistan. A screening strategy can be implemented after a large-scale study and financial considerations. One of the reduced cost screening strategies is seasonal screening of blood donors for WNV, with pooling of samples.
Mordal, Jon; Medhus, Sigrid; Holm, Bjørn; Mørland, Jørg; Bramness, Jørgen G
2013-06-01
In acute psychiatric services, rapid and accurate detection of psychoactive substance intake may be required for appropriate diagnosis and intervention. The aim of this study was to investigate the relationship between (a) drug influence as assessed by physicians and (b) blood drug concentrations among patients admitted to acute psychiatric wards. We also explored the possible effects of age, sex, and psychotic symptoms on physician's assessment of drug influence. In a cross-sectional study, the sample comprised 271 consecutive admissions from 2 acute psychiatric wards. At admission, the physician on call performed an overall judgment of drug influence. Psychotic symptoms were assessed with the positive subscale of the Positive and Negative Syndrome Scale. Blood samples were screened for a wide range of psychoactive substances, and quantitative results were used to calculate blood drug concentration scores. Patients were judged as being under the influence of drugs and/or alcohol in 28% of the 271 admissions. Psychoactive substances were detected in 56% of the blood samples. Altogether, 15 different substances were found; up to 8 substances were found in samples from 1 patient. Markedly elevated blood drug concentration scores were estimated for 15% of the patients. Physician's assessment was positively related to the blood drug concentration scores (r = 0.52; P < 0.001), to symptoms of excitement, and to the detection of alcohol, cannabis, and amphetamines. The study demonstrates the major impact of alcohol and drugs in acute psychiatric settings and illustrates the challenging nature of the initial clinical assessment.
Metabolic and respiratory status of cold-stunned Kemp's ridley sea turtles (Lepidochelys kempii).
Innis, Charles J; Tlusty, Michael; Merigo, Constance; Weber, E Scott
2007-08-01
"Cold-stunning" of sea turtles has been reported as a naturally occurring stressor for many years; however, the physiologic status of cold-stunned turtles has only been partially described. This study investigated initial and convalescent venous blood gas, acid-base, and critical plasma biochemical data for 26 naturally cold-stunned Kemp's ridley sea turtles (Lepidochelys kempii) from Cape Cod, MA, USA. Samples were analyzed for pH, pCO(2), pO(2), bicarbonate, plasma osmolality, sodium, potassium, chloride, ionized calcium, ionized magnesium, glucose, lactate, and blood urea nitrogen using a clinical point-of-care analyzer. Data were corrected for the patient's body temperature using both species-specific and more general correction methods. In general, venous blood gas, acid-base, and plasma biochemical data obtained for surviving cold-stunned Kemp's ridley sea turtles were consistent with previously documented data for sea turtles exposed to a wide range of temperatures and physiologic stressors. Data indicated that turtles were initially affected by metabolic and respiratory acidosis. Initial pH-corrected ionized calcium concentrations were lower than convalescent concentrations, and initial pH-corrected ionized magnesium concentrations were higher than convalescent concentrations.
Platelet factor 4/heparin antibodies in blood bank donors.
Hursting, Marcie J; Pai, Poulomi J; McCracken, Julianna E; Hwang, Fred; Suvarna, Shayela; Lokhnygina, Yuliya; Bandarenko, Nicholas; Arepally, Gowthami M
2010-11-01
Platelet factor 4 (PF4)/heparin antibody, typically associated with heparin therapy, is reported in some heparin-naive people. Seroprevalence in the general population, however, remains unclear. We prospectively evaluated PF4/heparin antibody in approximately 4,000 blood bank donors using a commercial enzyme-linked immunosorbent assay for initial and then repeated (confirmatory) testing. Antibody was detected initially in 249 (6.6%; 95% confidence interval [CI], 5.8%-7.4%) of 3,795 donors and repeatedly in 163 (4.3%; 95% CI, 3.7%-5.0%) of 3,789 evaluable donors. "Unconfirmed" positives were mostly (93%) low positives (optical density [OD] = 0.40-0.59). Of 163 repeatedly positive samples, 116 (71.2%) were low positives, and 124 (76.1%) exhibited heparin-dependent binding. Predominant isotypes of intermediate to high seropositive samples (OD >0.6) were IgG (20/39 [51%]), IgM (9/39 [23%]), and indeterminate (10/39 [26%]). The marked background seroprevalence of PF4/heparin antibody (4.3%-6.6%) with the preponderance of low (and frequently nonreproducible) positives in blood donors suggests the need for further assay calibration, categorization of antibody level, and studies evaluating clinical relevance of "naturally occurring" PF4/heparin antibodies.
Frickmann, Hagen; Hinz, Rebecca; Rojak, Sandra; Bonow, Insa; Ruben, Stefanie; Wegner, Christine; Zielke, Iris; Hagen, Ralf Matthias; Tannich, Egbert
2018-05-12
We assessed a commercial loop-mediated amplification (LAMP) platform for its reliability as a screening tool for malaria parasite detection. A total of 1000 blood samples from patients with suspected or confirmed malaria submitted to the German National Reference Center for Tropical Pathogens were subjected to LAMP using the Meridian illumigene Malaria platform. Results were compared with microscopy from thick and thin blood films in all cases. In case of discordant results between LAMP and microscopy (n = 60), confirmation testing was performed with real-time PCR. Persistence of circulating parasite DNA was analyzed by serial assessments of blood samples following malaria treatment. Out of 1000 blood samples analyzed, 238 were positive for malaria parasites according to microscopy (n = 181/1000) or PCR (additional n = 57/60). LAMP demonstrated sensitivity of 98.7% (235/238), specificity of 99.6% (759/762), positive predictive value (PPV) of 98.7% (235/238) and negative predictive value (NPV) of 99.6% (759/762), respectively. For first slides of patients with malaria and for follow-up slides, sensitivity values were 99.1% (106/107) and 98.5% (129/131), respectively. The performance of the Meridian illumigene Malaria platform is suitable for initial screening of patients suspected of clinical malaria. Copyright © 2018 Elsevier Ltd. All rights reserved.
Soejima, Mikiko; Tsuchiya, Yuji; Egashira, Kouichi; Kawano, Hiroyuki; Sagawa, Kimitaka; Koda, Yoshiro
2010-06-01
Anhaptoglobinemic patients run the risk of severe anaphylactic transfusion reaction because they produce serum haptoglobin (Hp) antibodies. Being homozygous for the Hp gene deletion (HP(del)) is the only known cause of congenital anhaptoglobinemia, and clinical diagnosis of HP(del) before transfusion is important to prevent anaphylactic shock. We recently developed a 5'-nuclease (TaqMan) real-time polymerase chain reaction (PCR) method. A SYBR Green I-based duplex real-time PCR assay using two forward primers and a common reverse primer followed by melting curve analysis was developed to determine HP(del) zygosity in a single tube. In addition, to obviate initial DNA extraction, we examined serially diluted blood samples as PCR templates. Allelic discrimination of HP(del) yielded optimal results at blood sample dilutions of 1:64 to 1:1024. The results from 2231 blood samples were fully concordant with those obtained by the TaqMan-based real-time PCR method. The detection rate of the HP(del) allele by the SYBR Green I-based method is comparable with that using the TaqMan-based method. This method is readily applicable due to its low initial cost and analyzability using economical real-time PCR machines and is suitable for high-throughput analysis as an alternative method for allelic discrimination of HP(del).
2009-01-01
Background Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Methods Five rapid HIV assays: Determine™ HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1–2.0 (PMC Medical India Pvt Ltd), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold™ HIV-1/2 (Trinity Biotech) were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Results Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold™ was 100% (95% CI; 99.1–100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2–99.9) and 97.7% (95% CI; 95.7–98.9), respectively, which increased to 100% (95% CI; 99.1–100) on repeat testing. The initial specificity of the Uni-Gold™ assay was 100% (95% CI; 99.6–100) while specificities were 99.6% (95% CI; 99–99.9), 99.4% (95% CI; 98.8–99.7), 99.6% (95% CI; 99–99.9) and 99.8% (95% CI; 99.3–99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold™, Determine and SD Bioline assays. Conclusion An alternative confirmatory HIV testing strategy based on initial testing on either SD Bioline or Determine assays followed by testing of reactive samples on the Determine or SD Bioline gave 100% sensitivity (95% CI; 99.1–100) and 100% specificity (95% CI; 96–99.1) with Uni-Gold™ as tiebreaker for discordant results. PMID:19226452
Lyamuya, Eligius F; Aboud, Said; Urassa, Willy K; Sufi, Jaffer; Mbwana, Judica; Ndugulile, Faustin; Massambu, Charles
2009-02-18
Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Five rapid HIV assays: Determine HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1-2.0 (PMC Medical India Pvt Ltd), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold HIV-1/2 (Trinity Biotech) were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold was 100% (95% CI; 99.1-100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2-99.9) and 97.7% (95% CI; 95.7-98.9), respectively, which increased to 100% (95% CI; 99.1-100) on repeat testing. The initial specificity of the Uni-Gold assay was 100% (95% CI; 99.6-100) while specificities were 99.6% (95% CI; 99-99.9), 99.4% (95% CI; 98.8-99.7), 99.6% (95% CI; 99-99.9) and 99.8% (95% CI; 99.3-99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold, Determine and SD Bioline assays. An alternative confirmatory HIV testing strategy based on initial testing on either SD Bioline or Determine assays followed by testing of reactive samples on the Determine or SD Bioline gave 100% sensitivity (95% CI; 99.1-100) and 100% specificity (95% CI; 96-99.1) with Uni-Gold as tiebreaker for discordant results.
2014-01-01
Background Levels of haemoglobin A1c (HbA1c) and blood lipids are important determinants of risk in patients with diabetes. Standard analysis methods based upon venous blood samples can be logistically challenging in resource-poor settings where much of the diabetes epidemic is occurring. Dried blood spots (DBS) provide a simple alternative method for sample collection but the comparability of data from analyses based on DBS is not well established. Methods We conducted a systematic review and meta-analysis to define the association of findings for HbA1c and blood lipids for analyses based upon standard methods compared to DBS. The Cochrane, Embase and Medline databases were searched for relevant reports and summary regression lines were estimated. Results 705 abstracts were found by the initial electronic search with 6 further reports identified by manual review of the full papers. 16 studies provided data for one or more outcomes of interest. There was a close agreement between the results for HbA1c assays based on venous and DBS samples (DBS = 0.9858venous + 0.3809), except for assays based upon affinity chromatography. Significant adjustment was required for assays of total cholesterol (DBS = 0.6807venous + 1.151) but results for triglycerides (DBS = 0.9557venous + 0.1427) were directly comparable. Conclusions For HbA1c and selected blood lipids, assays based on DBS samples are clearly associated with assays based on standard venous samples. There are, however, significant uncertainties about the nature of these associations and there is a need for standardisation of the sample collection, transportation, storage and analysis methods before the technique can be considered mainstream. This should be a research priority because better elucidation of metabolic risks in resource poor settings, where venous sampling is infeasible, will be key to addressing the global epidemic of cardiovascular diseases. PMID:25045323
Solanki, Archana; Singh, Abhay; Chaudhary, Rajendra
2016-01-01
Enzyme-linked immunosorbent assay (ELISA) used for screening blood donors for transfusion transmitted infections (TTIs) can sometimes fail to detect blood donors who are recently infected or possessing the low strength of pathogen. Estimation of a grey zone in ELISA testing and repeat testing of grey zone samples can further help in reducing the risks of TTI in countries where nucleic acid amplification testing for TTIs is not feasible. Grey zone samples with optical density (OD) lying between cut-off OD and 10% below the cut-off OD (cut-off OD × 0.9) were identified during routine ELISA testing. On performing repeat ELISA testing on grey zone samples in duplicate, the samples showing both OD value below grey zone were marked nonreactive, and samples showing one or both OD value in the grey zone were marked indeterminate. The samples on repeat testing showing one or both OD above cut-off value were marked positive. About 119 samples (77 for hepatitis B virus [HBV], 23 for human immunodeficiency virus [HIV], and 19 for hepatitis C virus [HCV]) were found to be in grey zone. On repeat testing of these samples in duplicate, 70 (58.8%) samples (45 for HBV, 12 for HIV, and 13 for HCV) were found to be reactive. Six (5%) samples (four for HBV, one for HIV, and one for HCV) were found to be indeterminate. Seventy donors initially screened negative, were found out to be potentially infectious on repeat grey zone testing. Thus, estimation of grey zone samples with repeat testing can further enhance the safety of blood transfusion.
Gas chromatography-mass spectrometry of biofluids and extracts.
Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Yang, Yang; Kharbatia, Najeh M
2015-01-01
Gas chromatography-mass spectrometry (GC-MS) has been widely used in metabonomics analyses of biofluid samples. Biofluids provide a wealth of information about the metabolism of the whole body and from multiple regions of the body that can be used to study general health status and organ function. Blood serum and blood plasma, for example, can provide a comprehensive picture of the whole body, while urine can be used to monitor the function of the kidneys, and cerebrospinal fluid (CSF) will provide information about the status of the brain and central nervous system (CNS). Different methods have been developed for the extraction of metabolites from biofluids, these ranging from solvent extracts, acids, heat denaturation, and filtration. These methods vary widely in terms of efficiency of protein removal and in the number of metabolites extracted. Consequently, for all biofluid-based metabonomics studies, it is vital to optimize and standardize all steps of sample preparation, including initial extraction of metabolites. In this chapter, recommendations are made of the optimum experimental conditions for biofluid samples for GC-MS, with a particular focus on blood serum and plasma samples.
Blood transfusion sampling and a greater role for error recovery.
Oldham, Jane
Patient identification errors in pre-transfusion blood sampling ('wrong blood in tube') are a persistent area of risk. These errors can potentially result in life-threatening complications. Current measures to address root causes of incidents and near misses have not resolved this problem and there is a need to look afresh at this issue. PROJECT PURPOSE: This narrative review of the literature is part of a wider system-improvement project designed to explore and seek a better understanding of the factors that contribute to transfusion sampling error as a prerequisite to examining current and potential approaches to error reduction. A broad search of the literature was undertaken to identify themes relating to this phenomenon. KEY DISCOVERIES: Two key themes emerged from the literature. Firstly, despite multi-faceted causes of error, the consistent element is the ever-present potential for human error. Secondly, current focus on error prevention could potentially be augmented with greater attention to error recovery. Exploring ways in which clinical staff taking samples might learn how to better identify their own errors is proposed to add to current safety initiatives.
Buckley, M G; Marcus, N J; Yacoub, M H
1999-12-01
Brain natriuretic peptide (BNP), atrial natriuretic peptide (ANP) and N-terminal ANP are good research indices of the severity of heart failure. The stability of these peptides at room temperature has become an important factor in assessing their use as indicators of cardiac function in routine clinical practice. Inhibitors such as aprotinin are routinely added in the blood collection process, but may provide no benefit in sample collection and routine clinical practice. We assessed the stability of BNP, ANP and N-terminal ANP in blood samples collected in either the presence or the absence of the protease inhibitor aprotinin. Blood, either with or without aprotinin, was processed immediately (initial; 0 h) and after blood samples had been left for 3 h, 2 days or 3 days at room temperature. These times were chosen to reflect processing in a hospital outpatient clinic (2-3 h), or when posted from general practice (2-3 days). Initial plasma BNP, ANP and N-terminal ANP levels in the absence of aprotinin were 28.2+/-5.4, 44.2+/-7.9 and 1997+/-608 pg/ml respectively, and were not significantly different from initial values in the presence of aprotinin (29.0+/-5.9, 45.2+/-8.0 and 2009+/-579 pg/ml respectively). After 3 h at room temperature, there was a significant fall in ANP in the absence of aprotinin (36. 7+/-7.9 pg/ml; P<0.005), but not in the presence of aprotinin (41. 2+/-7.6 pg/ml). Both BNP and N-terminal ANP were unchanged in either the absence (BNP, 27.6+/-5.5 pg/ml; N-terminal ANP, 2099+/-613 pg/ml) or the presence (BNP, 29.4+/-5.6 pg/ml; N-terminal ANP, 1988+/-600 pg/ml) of aprotinin. After 2 days at room temperature, ANP had fallen significantly in both the absence (16.9+/-3.4 pg/ml) and the presence (24.0+/-5.0 pg/ml) of aprotinin compared with initial values, and there was a significant difference in ANP levels in the absence and presence of aprotinin (P<0.001). ANP levels had decreased further after 3 days at room temperature, to 11.9+/-3.4 pg/ml (no aprotinin) and 20.3+/-5.0 pg/ml (aprotinin added); these values were significantly different (P=0.002). In contrast, there was no change in the levels of BNP or N-terminal ANP after 2 or 3 days at room temperature, in either the absence or the presence of aprotinin. These studies indicate that aprotinin adds little benefit to the stability of cardiac peptides at room temperature. Blood samples for BNP and N-terminal ANP measurement used as a test of heart function in hospital clinics and by general practitioners in the community could be taken into blood tubes containing only EDTA as anticoagulant and without the additional step of adding the routinely used inhibitor aprotinin.
Delivery route determines the presence of immune complexes on umbilical cord erythrocytes.
de Lima, Andrés; Franco, Luis C; Sarmiento, Andrés; González, John M
2017-11-01
Umbilical cord blood offers a unique opportunity to study the basal level of immunoglobulin complexes. This study aims to determine the presence of immune complexes and complement deposition on erythrocytes from umbilical cord blood from normal, full-term pregnancies. In vitro pre-formed IgA, IgG, and IgM complexes were used as positive control for flow cytometry detection, and for C3d deposition. Blood samples (34) of umbilical cord blood taken from vaginal and cesarean deliveries were tested for the presence of immunoglobulin complexes. Fourteen samples from vaginal deliveries and 20 samples from cesarean deliveries were assessed. IgG and IgM complexes were detected on erythrocytes, whereas no IgA complexes or complement deposition was observed. Interestingly, the percentage of IgG complexes was higher on erythrocytes from vaginal delivery samples compared to those from cesarean deliveries. No other associations between immune complexes and other maternal or newborn variables were found. IgG and IgM complexes seem to be normally present on umbilical cord erythrocytes. Erythrocytes from vaginal deliveries have a higher percentage of IgG complexes present compared to that from cesarean deliveries. Since no C3d activity was detected, these complexes are non-pathological and should be part of the newborn's initial innate immune response.
Ganguly, Mohit; Miller, Stephanie; Mitra, Kunal
2015-11-01
Short pulse lasers with pulse durations in the range of nanoseconds and shorter are effective in the targeted delivery of heat energy for precise tissue heating and ablation. This photothermal therapy is useful where the removal of cancerous tissue sections is required. The objective of this paper is to use finite element modeling to demonstrate the differences in the thermal response of skin tissue to short-pulse and continuous wave laser irradiation in the initial stages of the irradiation. Models have been developed to validate the temperature distribution and heat affected zone during laser irradiation of excised rat skin samples and live anesthetized mouse tissue. Excised rat skin samples and live anesthetized mice were subjected to Nd:YAG pulsed laser (1,064 nm, 500 ns) irradiation of varying powers. A thermal camera was used to measure the rise in surface temperature as a result of the laser irradiation. Histological analyses of the heat affected zone created in the tissue samples due to the temperature rise were performed. The thermal interaction of the laser with the tissue was quantified by measuring the thermal dose delivered by the laser. Finite element geometries of three-dimensional tissue sections for continuum and vascular models were developed using COMSOL Multiphysics. Blood flow was incorporated into the vascular model to mimic the presence of discrete blood vessels and contrasted with the continuum model without blood perfusion. The temperature rises predicted by the continuum and the vascular models agreed with the temperature rises observed at the surface of the excised rat tissue samples and live anesthetized mice due to laser irradiation respectively. The vascular model developed was able to predict the cooling produced by the blood vessels in the region where the vessels were present. The temperature rise in the continuum model due to pulsed laser irradiation was higher than that due to continuous wave (CW) laser irradiation in the initial stages of the irradiation. The temperature rise due to pulsed and CW laser irradiation converged as the time of irradiation increased. A similar trend was observed when comparing the thermal dose for pulsed and CW laser irradiation in the vascular model. Finite element models (continuum and vascular) were developed that can be used to predict temperature rise and quantify the thermal dose resulting from laser irradiation of excised rat skin samples and live anesthetized mouse tissue. The vascular model incorporating blood perfusion effects predicted temperature rise better in the live animal tissue. The models developed demonstrated that pulsed lasers caused greater temperature rise and delivered a greater thermal dose than CW lasers of equal average power, especially during the initial transients of irradiation. This analysis will be beneficial for thermal therapy applications where maximum delivery of thermal dose over a short period of time is important. © 2015 Wiley Periodicals, Inc.
Molecular genotyping of ABO blood groups in some population groups from India.
Ray, Sabita; Gorakshakar, Ajit C; Vasantha, K; Nadkarni, Anita; Italia, Yazdi; Ghosh, Kanjaksha
2014-01-01
Indian population is characterized by the presence of various castes and tribal groups. Various genetic polymorphisms have been used to differentiate among these groups. Amongst these, the ABO blood group system has been extensively studied. There is no information on molecular genotyping of ABO blood groups from India. Therefore, the main objective of this study was to characterize the common A, B and O alleles by molecular analysis in some Indian population groups. One hundred samples from the mixed population from Mumbai, 101 samples from the Dhodia tribe and 100 samples from the Parsi community were included in this study. Initially, the samples were phenotyped by standard serologic techniques. PCR followed by single strand conformational polymorphsim (SSCP) was used for molecular ABO genotyping. Samples showing atypical SSCP patterns were further analysed by DNA sequencing to characterize rare alleles. Seven common ABO alleles with 19 different genotypes were found in the mixed population. The Dhodias showed 12 different ABO genotypes and the Parsis revealed 15 different ABO genotypes with six common ABO alleles identified in each of them. Two rare alleles were also identified. This study reports the distribution of molecular genotypes of ABO alleles among some population groups from India. Considering the extremely heterogeneous nature of the Indian population, in terms of various genotype markers like blood groups, red cell enzymes, etc., many more ABO alleles are likely to be encountered.
Comparison of stored umbilical cord blood and adult donor blood: transfusion feasibility.
Tokan, Rola Sahyoun; Arsan, Saadet; Erdeve, Omer; Solaz, Nuri; Avcı, Aslıhan; Ulkar, Serenay Elgün; Gülyapar, Elif; Ustünyurt, Zeynep; Bıyıklı, Zeynep; Kemahlı, Sabri
2012-09-01
This study aimed to compare the storage properties of red blood cell (RBC) concentrates of umbilical cordblood (UCB) and adult donor blood (ADB), and to evaluate the feasibility of UCB-RBC concentrate as an autologoussource for blood transfusion in very low birth weight (VLBW) preterm neonates. In all, 30 newborn (10 preterm, 20 full term) UCB and 31 ADB units were collected.RBC concentrates were stored and compared with regard to pH, potassium (K(+)), 2,3-biphosphoglycerate (2-3-BPG),adenosine tri-phosphate (ATP), plasma Hb, and bacterial contamination on d 1, 21, and 35 of storage. The K(+) level increased with time and differed significantly between storage d 1 and 21, and between storaged 1 and 35 in both the UCB and ADB units. Initial and d 21 K(+) levels were higher in the UCB units than in the ADBunits. The 2,3-BPG level did not differ significantly between the UCB-PRC and ADB-PRC samples. After 35 d of storageboth UCB-PRC and ADB-PRC samples exhibited significant differences from the initial free Hb, intracellular ATP, andpH values. Significant differences in intracellular ATP and pH were also observed between the UCB-PRC and ADB-PRCsamples. The volume of harvested and prepared UCB-PRC can be used for some of the blood transfusions requiredduring the neonatal period and thus may decrease the number of allogeneic transfusions, especially in preterm newborns.The hematological and biochemical changes that occurred in UCB during storage were comparable with those observedin ADB, and do not pose a risk to the immature metabolism of neonates. UCB-RPC prepared and stored under standardconditions can be a safe alternative RBC source for transfusions in VLBW newborns.
Dioverti, M Veronica; Lahr, Brian D; Germer, Jeffrey J; Yao, Joseph D; Gartner, Michelle L; Razonable, Raymund R
2017-01-01
Quantification of cytomegalovirus (CMV) deoxyribonucleic acid (DNA) has important diagnostic, prognostic, and therapeutic implications in the management of transplant recipients. We aimed to assess a viral load in plasma and whole blood that distinguishes CMV disease from asymptomatic infection in a cohort of solid organ and hematopoietic stem cell transplantation. We prospectively measured and compared CMV viral load in paired plasma and whole blood samples collected from transplant recipients with CMV infection and disease. Cytomegalovirus viral loads were determined by a commercially available US Food and Drug Administration-approved quantitative assay (COBAS AmpliPrep/COBAS TaqMan CMV Test [CAP/CTM CMV]) calibrated to the first World Health Organization International Standard for CMV DNA quantification. Moderate agreement of CMV viral load was observed between plasma and whole blood, with 31% of samples having discordant findings, particularly among samples with low DNA levels. Among the subset of samples where both paired samples had quantifiable levels, we observed a systematic bias that reflected higher viral load in whole blood compared with plasma. Based on receiver operating curve analysis, an initial plasma CMV viral load threshold of 1700 IU/mL in solid organ transplant recipients (sensitivity 80%, specificity 74%) and 1350 IU/mL in allogeneic hematopoietic stem cell transplant recipients (sensitivity 87%, specificity 87%) distinguished CMV disease and asymptomatic infection. This study identifies standardized viral load thresholds that distinguish CMV disease from asymptomatic infection using CAP/CTM CMV assay. We propose these thresholds as potential triggers to be evaluated in prospective studies of preemptive therapy. Plasma was better than whole blood for measuring viral load using the CAP/CTM CMV assay.
Frequency of subgroups of the antigen “a” among volunteer donors
Parra-Jaramillo, Katherine; Chiriboga-Ponce, Rosa F
2018-01-01
The presence of weak variants of blood type A represents a challenge in the practice of immunohematology for discrepancies in the time of the classification. It is common in blood banks to perform a forward and reverse typing for the purpose of confirming the blood type, but not all the people with a subgroup A2 have developed anti-A1 antibodies. We present a descriptive, observational and transversal study that establishes the proportion of subgroups of A antigen with the analysis of manual tube technique and monoclonal antibodies like anti-A, anti-A1 (Dolichus biflorus lectins extract) and anti-H. The analysis involved a total of 818 samples of voluntary blood donor, selected by random sampling, which were initially classified as 737 of Type A, and 81 as Type AB, with a confidence level of 95% (alpha error of 5% and 3% of precision). The present study evaluated the existence of the subgroups A1, A2, A1B, A2B, A intermediate and A intB. It is recommended the identification of subgroups in different types of blood in the laboratory and blood banks. Copyright: © 2018 SecretarÍa de Salud
Lanteri, Marion C.; Lee, Tzong-Hae; Wen, Li; Kaidarova, Zhanna; Bravo, Marjorie D.; Kiely, Nancy E.; Kamel, Hany T.; Tobler, Leslie H.; Norris, Philip J.; Busch, Michael P.
2014-01-01
BACKGROUND Previous reports of WNV RNA persistence in blood compartments have raised concerns around the remaining risk of WNV transfusion-transmission. This study characterized the dynamics of WNV viremia in blood compartments in a longitudinal cohort of 54 WNV-infected blood donors. STUDY DESIGN AND METHODS Blood samples were collected throughout the year after WNV RNA+ blood donation (index) and characterized for anti-WNV IgM and IgG antibodies and for WNV RNA by real-time reverse-transcription polymerase chain reaction. WNV viral loads were compared in plasma and whole blood samples and correlated with blood groups and clinical outcomes. RESULTS WNV RNA persisted in the red blood cell (RBC) compartment up to three months post-index in 42% of the donors. Donors with the highest WNV RNA levels in plasma at index maintained the highest WNV RNA levels in whole blood over the three months post-index. Blood group A donors maintained higher post-index WNV viral load in whole blood than blood group O individuals (P=0.027). Despite a trend for WNV RNA to persist longer in whole blood from symptomatic subjects, no significant association was found between WNV RNA levels in whole blood and disease outcome. CONCLUSION This study confirmed that WNV RNA persists in the RBC fraction in whole blood and further suggested that the level of persistence in whole blood may be a reflection of initial viral burden in plasma. The association with blood groups suggests that WNV adherence to RBCs may be mediated by molecules overrepresented at the surface of blood group A RBCs. PMID:24965017
Lu, Sha; Li, Xiqing; Calderone, Richard; Zhang, Jing; Ma, Jianchi; Cai, Wenying; Xi, Liyan
2016-02-01
Talaromyces marneffei is a dimorphic pathogenic fungus, which is a life-threatening invasive mycosis in the immunocompromised host. Prompt diagnosis of T. marneffei infection remains difficult although there has been progress in attempts to expedite the diagnosis of this infection. We previously demonstrated the value of nested polymerase chain reaction (PCR) to detect T. marneffei in paraffin embedded tissue samples with high sensitivity and specificity. In this study, this assay was used to detect the DNA of T. marneffei in whole blood samples. Real-time PCR assay was also evaluated to identify T. marneffei in the same samples. Twenty out of 30 whole blood samples (67%) collected from 23 patients were found positive by using the nested PCR assay, while 23/30 (77%) samples were found positive by using the real-time PCR assay. In order to express accurately the fungal loads, we used a normalized linearized plasmid as an internal control for real-time PCR. The assay results were correlated as the initial quantity (copies/μl) with fungal burden. These data indicate that combination of nested PCR and real-time PCR assay provides an attractive alternative for identification of T. marneffei DNA in whole blood samples of HIV-infected patients. © The Author 2015. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Tran, Tuan M; Aghili, Amirali; Li, Shanping; Ongoiba, Aissata; Kayentao, Kassoum; Doumbo, Safiatou; Traore, Boubacar; Crompton, Peter D
2014-10-04
As public health efforts seek to eradicate malaria, there has been an emphasis on eliminating low-density parasite reservoirs in asymptomatic carriers. As such, diagnosing submicroscopic Plasmodium infections using PCR-based techniques has become important not only in clinical trials of malaria vaccines and therapeutics, but also in active malaria surveillance campaigns. However, PCR-based quantitative assays that rely on nucleic acid extracted from dried blood spots (DBS) have demonstrated lower sensitivity than assays that use cryopreserved whole blood as source material. The density of Plasmodium falciparum asexual parasites was quantified using genomic DNA extracted from dried blood spots (DBS) and the sensitivity of two approaches was compared: quantitative real-time PCR (qPCR) targeting the P. falciparum 18S ribosomal RNA gene, either with an initial conventional PCR amplification prior to qPCR (nested qPCR), or without an initial amplification (qPCR only). Parasite densities determined by nested qPCR, qPCR only, and light microscopy were compared. Nested qPCR results in 10-fold higher sensitivity (0.5 parasites/μl) when compared to qPCR only (five parasites/ul). Among microscopy-positive samples, parasite densities calculated by nested qPCR correlated strongly with microscopy for both asymptomatic (Pearson's r=0.58, P<0.001) and symptomatic (Pearson's r=0.70, P<0.0001) P. falciparum infections. Nested qPCR improves the sensitivity for the detection of P. falciparum blood-stage infection from clinical DBS samples. This approach may be useful for active malaria surveillance in areas where submicroscopic asymptomatic infections are prevalent.
Sample to answer visualization pipeline for low-cost point-of-care blood cell counting
NASA Astrophysics Data System (ADS)
Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter
2015-03-01
We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.
Kent, Shia T; Shimbo, Daichi; Huang, Lei; Diaz, Keith M; Kilgore, Meredith L; Oparil, Suzanne; Muntner, Paul
2014-01-01
After the 2003 publication of the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure (JNC 7) guidelines, there was a 5-10% increase in patients initiating antihypertensive medication with a thiazide-type diuretic, but most patients still did not initiate treatment with this class. There are few contemporary published data on antihypertensive medication classes filled by patients initiating treatment. We used the 5% random Medicare sample to study the initiation of antihypertensive medication between 2007 and 2010. Initiation was defined by the first antihypertensive medication fill preceded by 365 days with no antihypertensive medication fills. We restricted our analysis to beneficiaries ≥ 65 years who had two or more outpatient visits with a hypertension diagnosis and full Medicare fee-for-service coverage for the 365 days prior to initiation of antihypertensive medication. Between 2007 and 2010, 32,142 beneficiaries in the 5% Medicare sample initiated antihypertensive medication. Initiation with a thiazide-type diuretic decreased from 19.2% in 2007 to 17.9% in 2010. No other changes in medication classes initiated occurred over this period. Among those initiating antihypertensive medication in 2010, 31.3% filled angiotensin-converting enzyme inhibitors (ACE-Is), 26.9% filled beta blockers, 17.2% filled calcium channel blockers, and 14.4% filled angiotensin receptor blockers (ARBs). Initiation with >1 antihypertensive medication class decreased from 25.6% in 2007 to 24.1% in 2010. Patients initiated >1 antihypertensive medication class most commonly with a thiazide-type diuretic and either an ACE-I or ARB. These results suggest that JNC 7 had a limited long-term impact on the choice of antihypertensive medication class and provide baseline data prior to the publication of the 2014 Evidence-Based Guideline for the Management of High Blood Pressure in Adults from the Panel Members Appointed to the Eighth Joint National Committee (JNC 8).
Children's views on microneedle use as an alternative to blood sampling for patient monitoring.
Mooney, Karen; McElnay, James C; Donnelly, Ryan F
2014-10-01
To explore children's views on microneedle use for this population, particularly as an alternative approach to blood sampling, in monitoring applications, and so, examine the acceptability of this approach to children. Focus groups were conducted with children (aged 10-14 years) in a range of schools across Northern Ireland. Convenience sampling was employed, i.e. children involved in a university-directed community-outreach project (Pharmacists in Schools) were recruited. A total of 86 children participated in 13 focus groups across seven schools in Northern Ireland. A widespread disapproval for blood sampling was evident, with pain, blood and traditional needle visualisation particularly unpopular aspects. In general, microneedles had greater visual acceptability and caused less fear. A patch-based design enabled minimal patient awareness of the monitoring procedure, with personalised designs, e.g. cartoon themes, favoured. Children's concerns included possible allergy and potential inaccuracies with this novel approach; however, many had confidence in the judgement of healthcare professionals if deeming this technique appropriate. They considered paediatric patient education critical for acceptance of this new approach and called for an alternative name, without any reference to 'needles'. The findings presented here support the development of blood-free, minimally invasive techniques and provide an initial indication of microneedle acceptability in children, particularly for monitoring purposes. A proactive response to these unique insights should enable microneedle array design to better meet the needs of this end-user group. Further work in this area is recommended to ascertain the perspectives of a purposive sample of children with chronic conditions who require regular monitoring. © 2013 Royal Pharmaceutical Society.
Cermáková, Zuzana; Prásil, Petr; Valenta, Zbynek; Förstl, Miroslav; Plísková, Lenka; Bolehovská, Radka
2009-08-01
Infections caused by pathogenic protozoan Toxoplasma gondii in our geographic area is the most frequent parasitic infection; Czech Republic declares seroprevalence approx. 30 %. Diagnosis of toxoplasmosis is mostly based on serological methods are used (EIA IgM, IgA, IgE, IgG and avidity in IgG, Western Blot, complement fixation). According to positive results of these tests diagnosis of acute toxoplasmosis is established. In our retrospective study we tried to evaluate results of T. gondii DNA positivity from blood samples by PCR compared with positive markers of acute infection in patients before specific therapy was initiated. In accordance with literature we concluded, that in routine examination of immunocompetent outpatients of Clinic of Infectious Diseases from the moment of 4 weeks after lymphatic nodes swelling protozoan DNA detection in blood sample is not possible.
Citizens in the commons: blood and genetics in the making of the civic
Reddy, Deepa S.
2013-01-01
This essay is based on ethnographic fieldwork conducted with the Indian community in Houston, as part of a NIH/NHGRI-sponsored ethics study and sample collection initiative entitled ‘Indian and Hindu Perspectives on Genetic Variation Research.’ Taking a cue from my Indian interlocutors who largely support and readily respond to such initiatives on the grounds that they will undoubtedly serve ‘humanity’ and the common good, I explore notions of the commons that are created in the process of soliciting blood for genetic research. How does blood become the stuff of which a civic discourse is made? How do idealistic individual appeals to donate blood, ethics research protocols, open-source databases, debates on approaches to genetic research, patents and Intellectual Property regulations, markets and the nation-state itself variously engage, limit or further ideas of the common good? Moving much as my interlocutors do, between India and the United States, I explore the nature of the commons that is both imagined and pragmatically reckoned in both local and global diasporic contexts. PMID:24478538
[Blood culture negative endocarditis: a diagnostic challenge].
Wälli, F; Chuard, C; Regamey, C
2005-10-12
Blood culture negative endocarditis (BCNE) account for about 5% of all cases of endocarditis. Diagnosis and initiation of antimicrobial therapy may be delayed, with a negative impact on clinical outcome. The most common cause of BCNE is antimicrobial drug therapy before blood sampling. Other common causes include slow growing and non cultivable organisms. Identification of the etiologic agent is critical in the management of BCNE and molecular tools such as broad range 16SrRNA PCR technique followed by direct automated sequencing and microorganism-specific PCR are promising. Some authors have proposed to include these techniques among major Duke's criteria for the diagnosis of BCNE.
Influence of videofilm-induced emotional stress on the flow properties of blood.
Ehrly, A M; Landgraf, H; Hessler, J; Saeger-Lorenz, K
1988-04-01
The hemorheologic effects of emotional stress induced by a videofilm were investigated in 10 healthy volunteers. Blood samples were obtained from the antecubital vein before, during, and after the end of the videofilm. Blood pressure and heart rate were simultaneously measured. There was a statistically significant increase in blood and plasma viscosity during and immediately after the end of the videofilm, which correlated with an increase in plasma catecholamine concentrations. This hemorheologic behavior can be explained as a result of an endogenous hemoconcentration that takes place if the Starling equilibrium of intravascular vs extravascular fluid is changed. These observations could lead to new aspects of the pathophysiology of acute myocardial infarction initiated by severe emotional stress.
Microfluidic point-of-care blood panel based on a novel technique: Reversible electroosmotic flow
Mohammadi, Mahdi; Madadi, Hojjat; Casals-Terré, Jasmina
2015-01-01
A wide range of diseases and conditions are monitored or diagnosed from blood plasma, but the ability to analyze a whole blood sample with the requirements for a point-of-care device, such as robustness, user-friendliness, and simple handling, remains unmet. Microfluidics technology offers the possibility not only to work fresh thumb-pricked whole blood but also to maximize the amount of the obtained plasma from the initial sample and therefore the possibility to implement multiple tests in a single cartridge. The microfluidic design presented in this paper is a combination of cross-flow filtration with a reversible electroosmotic flow that prevents clogging at the filter entrance and maximizes the amount of separated plasma. The main advantage of this design is its efficiency, since from a small amount of sample (a single droplet ∼10 μl) almost 10% of this (approx 1 μl) is extracted and collected with high purity (more than 99%) in a reasonable time (5–8 min). To validate the quality and quantity of the separated plasma and to show its potential as a clinical tool, the microfluidic chip has been combined with lateral flow immunochromatography technology to perform a qualitative detection of the thyroid-stimulating hormone and a blood panel for measuring cardiac Troponin and Creatine Kinase MB. The results from the microfluidic system are comparable to previous commercial lateral flow assays that required more sample for implementing fewer tests. PMID:26396660
Effects of Aggregation on Blood Sedimentation and Conductivity
Zhbanov, Alexander; Yang, Sung
2015-01-01
The erythrocyte sedimentation rate (ESR) test has been used for over a century. The Westergren method is routinely used in a variety of clinics. However, the mechanism of erythrocyte sedimentation remains unclear, and the 60 min required for the test seems excessive. We investigated the effects of cell aggregation during blood sedimentation and electrical conductivity at different hematocrits. A sample of blood was drop cast into a small chamber with two planar electrodes placed on the bottom. The measured blood conductivity increased slightly during the first minute and decreased thereafter. We explored various methods of enhancing or retarding the erythrocyte aggregation. Using experimental measurements and theoretical calculations, we show that the initial increase in blood conductivity was indeed caused by aggregation, while the subsequent decrease in conductivity resulted from the deposition of erythrocytes. We present a method for calculating blood conductivity based on effective medium theory. Erythrocytes are modeled as conducting spheroids surrounded by a thin insulating membrane. A digital camera was used to investigate the erythrocyte sedimentation behavior and the distribution of the cell volume fraction in a capillary tube. Experimental observations and theoretical estimations of the settling velocity are provided. We experimentally demonstrate that the disaggregated cells settle much slower than the aggregated cells. We show that our method of measuring the electrical conductivity credibly reflected the ESR. The method was very sensitive to the initial stage of aggregation and sedimentation, while the sedimentation curve for the Westergren ESR test has a very mild slope in the initial time. We tested our method for rapid estimation of the Westergren ESR. We show a correlation between our method of measuring changes in blood conductivity and standard Westergren ESR method. In the future, our method could be examined as a potential means of accelerating ESR tests in clinical practice. PMID:26047511
Rubin, Olivier; Delobel, Julien; Prudent, Michel; Lion, Niels; Kohl, Kid; Tucker, Erik I; Tissot, Jean-Daniel; Angelillo-Scherrer, Anne
2013-08-01
Red blood cell-derived microparticles (RMPs) are small phospholipid vesicles shed from RBCs in blood units, where they accumulate during storage. Because microparticles are bioactive, it could be suggested that RMPs are mediators of posttransfusion complications or, on the contrary, constitute a potential hemostatic agent. This study was performed to establish the impact on coagulation of RMPs isolated from blood units. Using calibrated automated thrombography, we investigated whether RMPs affect thrombin generation (TG) in plasma. We found that RMPs were not only able to increase TG in plasma in the presence of a low exogenous tissue factor (TF) concentration, but also to initiate TG in plasma in absence of exogenous TF. TG induced by RMPs in the absence of exogenous TF was neither affected by the presence of blocking anti-TF nor by the absence of Factor (F)VII. It was significantly reduced in plasma deficient in FVIII or F IX and abolished in FII-, FV-, FX-, or FXI-deficient plasma. TG was also totally abolished when anti-XI 01A6 was added in the sample. Finally, neither Western blotting, flow cytometry, nor immunogold labeling allowed the detection of traces of TF antigen. In addition, RMPs did not comprise polyphosphate, an important modulator of coagulation. Taken together, our data show that RMPs have FXI-dependent procoagulant properties and are able to initiate and propagate TG. The anionic surface of RMPs might be the site of FXI-mediated TG amplification and intrinsic tenase and prothrombinase complex assembly. © 2012 American Association of Blood Banks.
Cartledge, Victoria A; Gartrell, Brett; Jones, Susan M
2005-05-01
This study investigates the relationships between plasma corticosterone concentrations and white cell counts in captive females of the viviparous lizard Egernia whitii during two phases of the reproductive cycle. Gestating and postpartum females were captured in the field and held in the laboratory for 4 weeks. Plasma corticosterone and progesterone concentrations and white blood cell counts were examined in blood samples taken at capture and after 24 h, 1 week, and 4 weeks in captivity. At 24 h after capture, plasma corticosterone concentrations in both groups had increased significantly compared with initial values but then returned to initial concentrations after 1 week in captivity and remained low in the 4 week samples. Plasma progesterone concentrations remained elevated in the gestating females until the week 4 sample, just prior to parturition. The hormone data suggest that capture and captivity did not represent a significant long-term stressor to these animals. The increase in plasma corticosterone concentration was associated with heterophilia in the differential leucocyte count in both groups of females. Lymphocyte numbers decreased only in gestating females, suggesting that reproductive status may influence the interaction between adrenal activity and immune function.
Thiha, Soe; Shewade, Hemant Deepak; Philip, Sairu; Aung, Thet Ko; Kyaw, Nang Thu Thu; Oo, Myo Minn; Kyaw, Khine Wut Yee; War, May Wint; Oo, Htun Nyunt
2017-01-01
In collaboration with the national AIDS program, early infant diagnosis (EID) is implemented by Integrated HIV Care (IHC) program through its anti-retroviral therapy (ART) centers across 10 cities in five states and regions of Myanmar. Blood samples from the ART centers are sent using public transport to a centralized PCR facility. Among HIV-exposed babies <9 months at enrolment into IHC program (2013-15), to describe the EID cascade (enrolment, sample collection for PCR, result receipt by mother, HIV diagnosis and ART initiation) and factors associated with delayed (>8 weeks of age) or no blood sample collection for EID. Retrospective cohort study involving record review. A predictive poisson regression model with robust variance estimates was fitted for risk factors of delayed or no sample collection. Of 1349 babies, 523 (39%) of the babies' mothers were on ART before pregnancy. Timely uptake of EID (<8 weeks of age) was 47% (633/1349); sample collection was delayed in 27% (367/1349) and not done in 26% (349/1349) babies. Among samples collected (n = 1000), 667 results were received by the mother; 52 (5%) were HIV-infected; among them 42 (81%) were initiated on ART. Median (IQR) turnaround time from sample collection to result receipt by mother and time to initiate ART from result receipt by mother was 7 (4,12) and 8.5 (6,16) weeks, respectively. Mothers not on ART before pregnancy and distance of ART center from PCR facility (more than 128 km) were the risk factors of delayed or no sample collection. Improving provision of ART to mothers (through universal 'test and treat') is urgently required, which has the potential to improve the timely uptake of EID as well. Interventions to reduce turnaround times, like point of care EID testing and/or systematic use of mobile technology to communicate results, are needed.
Brito, Barbara P; Gardner, Ian A; Hietala, Sharon K; Crossley, Beate M
2011-07-01
Bluetongue is a vector-borne viral disease that affects domestic and wild ruminants. The epidemiology of this disease has recently changed, with occurrence in new geographic areas. Various real-time quantitative reverse transcription polymerase chain reaction (real-time qRT-PCR) assays are used to detect Bluetongue virus (BTV); however, the impact of biologic differences between New World camelids and domestic ruminant samples on PCR efficiency, for which the BTV real-time qRT-PCR was initially validated are unknown. New world camelids are known to have important biologic differences in whole blood composition, including hemoglobin concentration, which can alter PCR performance. In the present study, sheep, cattle, and alpaca blood were spiked with BTV serotypes 10, 11, 13, and 17 and analyzed in 10-fold dilutions by real-time qRT-PCR to determine if species affected nucleic acid recovery and assay performance. A separate experiment was performed using spiked alpaca blood subsequently diluted in 10-fold series in sheep blood to assess the influence of alpaca blood on performance efficiency of the BTV real-time qRT-PCR assay. Results showed that BTV-specific nucleic acid detection from alpaca blood was consistently 1-2 logs lower than from sheep and cattle blood, and results were similar for each of the 4 BTV serotypes analyzed.
2010-01-01
Background The existence of circulating tumor cells (CTCs) in peripheral blood as an indicator of tumor recurrence has not been clearly established, particularly for gastric cancer patients. We conducted a retrospective analysis of the relationship between CTCs in peripheral blood at initial diagnosis and clinicopathologic findings in patients with gastric carcinoma. Methods Blood samples were obtained from 123 gastric carcinoma patients at initial diagnosis. mRNA was extracted and amplified for carcinoembryonic antigen (CEA) mRNA detection using real-time RT-PCR. Periodic 3-month follow-up examinations included serum CEA measurements and imaging. Results The minimum threshold for corrected CEA mRNA score [(CEA mRNA/GAPDH mRNA) × 106] was set at 100. Forty-five of 123 patients (36.6%) were positive for CEA mRNA expression. CEA mRNA expression significantly correlated with T stage and postoperative recurrence status (P = 0.001). Recurrent disease was found in 44 of 123 cases (35.8%), and 25 of these (56.8%) were positive for CEA mRNA. Of these patients, CEA mRNA was more sensitive than serum CEA in indicating recurrence. Three-year disease-free survival of patients positive for CEA mRNA was significantly poorer than of patients negative for CEA mRNA (P < 0.001). Only histological grade and CEA mRNA positivity were independent factors for disease-free survival using multivariate analysis. Conclusions CEA mRNA copy number in peripheral blood at initial diagnosis was significantly associated with disease recurrence in gastric adenocarcinoma patients. Real-time RT-PCR detection of CEA mRNA levels at initial diagnosis appears to be a promising predictor for disease recurrence in gastric adenocarcinoma patients. PMID:21040522
Qiu, Miao-Zhen; Li, Zhuang-Hua; Zhou, Zhi-Wei; Li, Yu-Hong; Wang, Zhi-Qiang; Wang, Feng-Hua; Huang, Peng; Aziz, Fahad; Wang, Dao-Yuan; Xu, Rui-Hua
2010-10-31
The existence of circulating tumor cells (CTCs) in peripheral blood as an indicator of tumor recurrence has not been clearly established, particularly for gastric cancer patients. We conducted a retrospective analysis of the relationship between CTCs in peripheral blood at initial diagnosis and clinicopathologic findings in patients with gastric carcinoma. Blood samples were obtained from 123 gastric carcinoma patients at initial diagnosis. mRNA was extracted and amplified for carcinoembryonic antigen (CEA) mRNA detection using real-time RT-PCR. Periodic 3-month follow-up examinations included serum CEA measurements and imaging. The minimum threshold for corrected CEA mRNA score [(CEA mRNA/GAPDH mRNA) × 106] was set at 100. Forty-five of 123 patients (36.6%) were positive for CEA mRNA expression. CEA mRNA expression significantly correlated with T stage and postoperative recurrence status (P = 0.001). Recurrent disease was found in 44 of 123 cases (35.8%), and 25 of these (56.8%) were positive for CEA mRNA. Of these patients, CEA mRNA was more sensitive than serum CEA in indicating recurrence. Three-year disease-free survival of patients positive for CEA mRNA was significantly poorer than of patients negative for CEA mRNA (P < 0.001). Only histological grade and CEA mRNA positivity were independent factors for disease-free survival using multivariate analysis. CEA mRNA copy number in peripheral blood at initial diagnosis was significantly associated with disease recurrence in gastric adenocarcinoma patients. Real-time RT-PCR detection of CEA mRNA levels at initial diagnosis appears to be a promising predictor for disease recurrence in gastric adenocarcinoma patients.
GOOD GIFTS FOR THE COMMON GOOD: Blood and Bioethics in the Market of Genetic Research
REDDY, DEEPA S.
2008-01-01
This article is based on ethnographic fieldwork conducted with the Indian community in Houston, as part of a NIH–NHGRI-sponsored ethics study and sample collection initiative entitled “Indian and Hindu Perspectives on Genetic Variation Research.” At the heart of this research is one central exchange—blood samples donated for genetic research—that draws both the Indian community and a community of researchers into an encounter with bioethics. I consider the meanings that come to be associated with blood donation as it passes through various hands, agendas, and associated ethical filters on its way to the lab bench: how and why blood is solicited, how the giving and taking of blood is rationalized, how blood as material substance is alienated, processed, documented, and made available for the promised ends of basic science research. Examining corporeal substances and asking what sorts of gifts and problems these represent, I argue, sheds some light on two imbricated tensions expressed by a community of Indians, on the one hand, and of geneticists and basic science researchers, on the other hand: that gifts ought to be free (but are not), and that science ought to be pure (but is not). In this article, I explore how experiences of bioethics are variously shaped by the histories and habits of Indic giving, prior sample collection controversies, commitments to “good science” and the common “good of humanity,” and negotiations of the sites where research findings circulate. PMID:18458755
Reiter, Georg; Mikler, John; Hill, Ira; Weatherby, Kendal; Thiermann, Horst; Worek, Franz
2011-09-15
The present study was initiated to develop a sensitive and highly selective method for the simultaneous quantification of the nerve agent VX (O-ethyl S-[2(diisopropylamino)ethyl] methylphosphonothioate) and its toxic metabolite (EA-2192) in blood and plasma samples in vivo and in vitro. For the quantitative detection of VX and EA-2192 the resolution was realized on a HYPERCARB HPLC phase. A specific procedure was developed to isolate both toxic analytes from blood and plasma samples. The limit of detection was 0.1 pg/ml and the absolute recovery of the overall sample preparation procedure was 74% for VX and 69% for EA-2192. After intravenous and percutaneous administration of a supralethal doses of VX in anaesthetised swine both VX and EA-2192 could be quantified over 540 min following exposure. This study is the first to verify the in vivo formation of the toxic metabolite EA-2192 after poisoning with the nerve agent VX. Further toxicokinetic and therapeutic studies are required in order to determine the impact of EA-2192 on the treatment of acute VX poisoning. Copyright © 2011 Elsevier B.V. All rights reserved.
Seroprevalence of human parvovirus B19 in healthy blood donors
Kumar, Satish; Gupta, R.M.; Sen, Sourav; Sarkar, R.S.; Philip, J.; Kotwal, Atul; Sumathi, S.H.
2013-01-01
Background Human parvovirus B19 is an emerging transfusion transmitted infection. Although parvovirus B19 infection is connected with severe complications in some recipients, donor screening is not yet mandatory. To reduce the risk of contamination, plasma-pool screening and exclusion of highly viraemic donations are recommended. In this study the prevalence of parvovirus B19 in healthy blood donors was detected by ELISA. Methods A total of 1633 samples were screened for IgM and IgG antibodies against parvovirus B19 by ELISA. The initial 540 samples were screened for both IgM and IgG class antibodies and remaining 1093 samples were screened for only IgM class antibodies by ELISA. Results Net prevalence of IgM antibodies to human parvovirus B19 in our study was 7.53% and prevalence of IgG antibodies was 27.96%. Dual positivity (IgG and IgM) was 2.40%. Conclusion The seroprevalence of human parvovirus B19 among blood donor population in our study is high, and poses an adverse transfusion risk especially in high-risk group of patients who have no detectable antibodies to B19. Studies with large sample size are needed to validate these results. PMID:24600121
Seroprevalence of human parvovirus B19 in healthy blood donors.
Kumar, Satish; Gupta, R M; Sen, Sourav; Sarkar, R S; Philip, J; Kotwal, Atul; Sumathi, S H
2013-07-01
Human parvovirus B19 is an emerging transfusion transmitted infection. Although parvovirus B19 infection is connected with severe complications in some recipients, donor screening is not yet mandatory. To reduce the risk of contamination, plasma-pool screening and exclusion of highly viraemic donations are recommended. In this study the prevalence of parvovirus B19 in healthy blood donors was detected by ELISA. A total of 1633 samples were screened for IgM and IgG antibodies against parvovirus B19 by ELISA. The initial 540 samples were screened for both IgM and IgG class antibodies and remaining 1093 samples were screened for only IgM class antibodies by ELISA. Net prevalence of IgM antibodies to human parvovirus B19 in our study was 7.53% and prevalence of IgG antibodies was 27.96%. Dual positivity (IgG and IgM) was 2.40%. The seroprevalence of human parvovirus B19 among blood donor population in our study is high, and poses an adverse transfusion risk especially in high-risk group of patients who have no detectable antibodies to B19. Studies with large sample size are needed to validate these results.
Molecular genotyping of ABO blood groups in some population groups from India
Ray, Sabita; Gorakshakar, Ajit C.; Vasantha, K.; Nadkarni, Anita; Italia, Yazdi; Ghosh, Kanjaksha
2014-01-01
Background & objectives: Indian population is characterized by the presence of various castes and tribal groups. Various genetic polymorphisms have been used to differentiate among these groups. Amongst these, the ABO blood group system has been extensively studied. There is no information on molecular genotyping of ABO blood groups from India. Therefore, the main objective of this study was to characterize the common A, B and O alleles by molecular analysis in some Indian population groups. Methods: One hundred samples from the mixed population from Mumbai, 101 samples from the Dhodia tribe and 100 samples from the Parsi community were included in this study. Initially, the samples were phenotyped by standard serologic techniques. PCR followed by single strand conformational polymorphsim (SSCP) was used for molecular ABO genotyping. Samples showing atypical SSCP patterns were further analysed by DNA sequencing to characterize rare alleles. Results: Seven common ABO alleles with 19 different genotypes were found in the mixed population. The Dhodias showed 12 different ABO genotypes and the Parsis revealed 15 different ABO genotypes with six common ABO alleles identified in each of them. Two rare alleles were also identified. Interpretation & conclusions: This study reports the distribution of molecular genotypes of ABO alleles among some population groups from India. Considering the extremely heterogeneous nature of the Indian population, in terms of various genotype markers like blood groups, red cell enzymes, etc., many more ABO alleles are likely to be encountered. PMID:24604045
Flower, Jennifer E; Norton, Terry M; Andrews, Kimberly M; Nelson, Steven E; Parker, Clare E; Romero, L Michael; Mitchell, Mark A
2015-01-01
The evaluation of hormonal responses to stress in reptiles relies on acquisition of baseline corticosterone concentrations; however, the stress associated with the restraint needed to collect the blood samples can affect the results. The purpose of this study was to determine a time limit for the collection of blood samples to evaluate baseline corticosterone, haematological and biochemical results in nesting (n = 11) and rehabilitating (n = 16) loggerhead sea turtles (Caretta caretta). Blood samples were collected from the dorsal cervical sinus of each turtle immediately after touching the animal (t 0; 0-3 min) and 3 (t 3; 3-6 min), 6 (t 6; 6-9 min; nesting turtles only), 10 (t 10; 10-13 min) and 30 min (t 30; rehabilitating turtles only) after the initial hands-on time. Consistent between the rehabilitating and nesting turtles, there was a subtle yet significant increase in white blood cell counts over time. Despite the fact that white blood cell counts increased during the sampling period, there was no direct correlation between white blood cell count and corticosterone in the sampled turtles. In the nesting turtles, significant elevations in corticosterone were noted between t 0 and t 3 (P = 0.014) and between t 0 and t 6 (P = 0.022). Values at t 10 were not significantly different from those at t 0 (P = 0.102); however, there was a trend for the corticosterone values to continue to increase. These results suggest that sampling of nesting loggerhead sea turtles within 3 min of handling will provide baseline corticosterone concentrations in their natural environment. Significant elevations in corticosterone were also noted in the rehabilitating loggerhead sea turtles between t 0 and t 10 (P = 0.02) and between t 0 and t 30 of sampling (P = 0.0001). These results suggest that sampling of loggerhead sea turtles within 6 min of handling should provide baseline corticosterone concentrations in a rehabilitation setting. The delay in the corticosterone response noted in the rehabilitating turtles may be associated with the daily contact (visual or direct) they have with their human caretakers.
Sasanelli, Mariateresa; Paradies, Paola; Greco, Beatrice; Eyal, Osnat; Zaza, Valeria; Baneth, Gad
2010-08-04
The efficacy of imidocarb dipropionate for the treatment of Hepatozoon canis infection was studied in three naturally infected asymptomatic dogs followed longitudinally over 8 months. Response to treatment was followed by monitoring blood counts, parasitemia levels in blood, parasite in concentrated buffy-coat smears and by PCR. The dogs were initially treated with a low dose of 3 mg/kg imidocarb dipropionate twice a month and when parasitemia persisted after five treatments, with the regular dose of 6 mg/kg. In one dog, H. canis gamonts were no longer detectable by blood and buffy-coat microscopy after 2 months of therapy with 6 mg/kg while in the two other dogs gamonts were intermittently found in blood but persistently detectable in buffy-coat smears during the whole study period. Furthermore, combined therapy with doxycycline monohydrate administered at 10 mg/kg/day PO for 4 weeks also failed to eliminate H. canis. PCR revealed that parasite DNA was present in the blood of all dogs at all sampling dates regardless of treatment refuting the effectiveness of treatment suggested by negative blood microscopy. Detection of H. canis in buffy coat was found to be twice as sensitive than by blood smear and detection by PCR was even more sensitive revealing infection in eight samples (16% of total samples) negative by blood and buffy-coat microscopy. In conclusion, imidocarb dipropionate was not effective in eliminating H. canis from dogs treated repeatedly over 8 months. Microscopical detection is not sufficient for the evaluation of treatment response in H. canis infection and follow up by molecular techniques is recommended. Copyright 2010 Elsevier B.V. All rights reserved.
Automated processing of human bone marrow grafts for transplantation.
Zingsem, J; Zeiler, T; Zimmermanm, R; Weisbach, V; Mitschulat, H; Schmid, H; Beyer, J; Siegert, W; Eckstein, R
1993-01-01
Prior to purging or cryopreservation, we concentrated 21 bone marrow (BM) harvests using a modification of the 'grancollect-protocol' of the Fresenius AS 104 cell separator with the P1-Y set. Within 40-70 min, the initial marrow volume of 1,265 ml (+/- 537 ml) was processed two to three times. A mean of 47% (+/- 21%) of the initial mononuclear cells was recovered in a mean volume of 128 ml (+36 ml). The recovery of clonogenic cells, measured by CFU-GM assays, was 68% (+/- 47%). Red blood cells in the BM concentrates were reduced to 7% (+/- 4%) of the initial number. The procedure was efficient and yielded a BM cell fraction suitable for purging, cryopreservation and transplantation. At this time, 10 of the 21 patients whose BM was processed using this technique have been transplanted. Seven of these 10 patients have been grafted using the BM alone. Three of the 10 patients showed reduced cell viability and colony growth in the thawed BM samples, and therefore obtained BM and peripheral blood-derived stem cells. All transplanted patients showed an evaluable engraftment, achieving 1,000 granulocytes per microliter of peripheral blood in a mean of 18 days.
Freick, Markus; Konrath, Andrea; Enbergs, Haimo; Walraph, Jörg; Weber, Jim; Eulenberger, Karin
2018-03-01
Coxiella burnetii (C. burnetii), an intracellular zoonotic bacterium causing Q fever, occurs widely in cattle herds. After invasion of the pregnant uterus and initial localization in the placenta, active C. burnetii infections may spread to the fetus hematogenously or by the amniotic-oral route and thus may cause abortion, premature delivery, stillbirth, and weak offspring (APSW) complex. In a case-control study, we investigated precolostral blood samples of 56 stillborn calves and 30 live births from a dairy herd endemically infected with C. burnetii "C-cluster" strains and an increased stillbirth rate in primiparous cows. Within the group of the stillborn calves, four precolostral blood samples (7.1%) were tested positive for C. burnetii DNA by PCR and one serum sample (1.8%) positive for anti-C. burnetii IgG antibodies by a commercial ELISA test, respectively. Neither C. burnetii DNA nor anti-C. burnetii IgG antibodies were detected in the samples of calves being born alive. In conclusion, we demonstrated that coxiellaemia and precolostral seroconversion occurred sporadically in stillborn calves from this endemically infected herd. Due to the low detection rates, C. burnetii could not be confirmed to be the cause of the increased stillbirth rate.
Acierno, Mark J; Schnellbacher, Rodney; Tully, Thomas N
2012-12-01
Although abnormalities in blood glucose concentrations in avian species are not as common as they are in mammals, the inability to provide point-of-care glucose measurement likely results in underreporting and missed treatment opportunities. A veterinary glucometer that uses different optimization codes for specific groups of animals has been produced. To obtain data for a psittacine bird-specific optimization code, as well as to calculate agreement between the veterinary glucometer, a standard human glucometer, and a laboratory analyzer, blood samples were obtained from 25 Hispaniolan Amazon parrots (Amazona ventralis) in a 2-phase study. In the initial phase, blood samples were obtained from 20 parrots twice at a 2-week interval. For each sample, the packed cell volume was determined, and the blood glucose concentration was measured by the veterinary glucometer. The rest of each sample was placed into a lithium heparin microtainer tube and centrifuged, and plasma was removed and frozen at -30 degrees C. Within 5 days, tubes were thawed, and blood glucose concentrations were measured with a laboratory analyzer. The data from both procedures were used to develop a psittacine bird-specific code. For the second phase of the study, the same procedure was repeated twice at a 2-week interval in 25 birds to determine agreement between the veterinary glucometer, a standard human glucometer, and a laboratory analyzer. Neither glucometer was in good agreement with the laboratory analyzer (veterinary glucometer bias, 9.0; level of agreement, -38.1 to 56.2; standard glucometer bias, 69.4; level of agreement -17.8 to 156.7). Based on these results, the use of handheld glucometers in the diagnostic testing of Hispaniolan Amazon parrots and other psittacine birds cannot be recommended.
Walraph, J; Zoche-Golob, V; Weber, J; Freick, M
2018-06-01
In cattle, indirect enzyme-linked immunosorbent assay (ELISA) tests are commonly used in serological routine diagnostics. In a longitudinal study design, changes in relative optical density (OD) from drying-off until week 11 after calving were analyzed in blood and milk samples from pluriparous dairy cows (n=21) using a commercial indirect anti-C. burnetii ELISA test. In a second part of this study, changes over time were evaluated in blood and milk samples of 11 of these cows in an indirect ELISA detecting anti-Bovine viral diarrhea virus (BVDV) antibodies. Regarding the cows which were still in the herd at the time of calving, blood serological qualitative changes from positive to negative or indeterminate were demonstrated in 7/20 cows (35%) for the anti-C. burnetii indirect ELISA and in 2/10 cows (20%) for the anti-BVDV indirect ELISA, respectively, during the period from 14days ante partum to calving. Relative OD in the anti-C. burnetii and the anti-BVDV indirect ELISA tests followed basically similar courses over time. In blood serum, relative OD initially increased after drying-off, before a drop around calving was observed. After the colostrum period, relative OD in blood serum showed an increase until week 11 of lactation. In colostrum samples, relative OD levels were higher than in milk samples obtained one day before drying-off. After parturition, relative OD in milk decreased until week 6 of lactation in the anti-C. burnetii indirect ELISA and until week 11 in the anti-BVDV indirect ELISA, respectively. In conclusion, blood serological investigations in periparturient dairy cows using indirect ELISA kits should be avoided. Copyright © 2018 Elsevier Ltd. All rights reserved.
Delcò, Cristina; Karam, Oliver; Pfister, Riccardo; Gervaix, Alain; Renzi, Gesuele; Emonet, Stéphane; Schrenzel, Jacques; Posfay-Barbe, Klara M
2017-05-01
Sepsis is an important cause of morbidity and mortality in neonates and clinicians are typically required to administer empiric antibiotics while waiting for blood culture results. However, prolonged and inappropriate use of antibiotics is associated with various complications and adverse events. Better tools to rapidly rule out bacterial infections are therefore needed. We aimed to assess the negative predictive value of PCR coupled with Electrospray Ionization Mass Spectrometry (PCR/ESI-MS) compared to conventional blood cultures in neonatal sepsis. Prospective observational study. All consecutive neonates (<28days old) with clinical suspicion of sepsis. Samples for PCR/ESI-MS analysis were collected at the same time as samples for the blood culture, before the initiation of antibiotics. Our primary objective was to evaluate the negative predictive value of PCR/ESI-MS for the detection of bacteria in the bloodstream of newborns with suspected sepsis. Our secondary objective was the evaluation of the sensitivity, specificity and positive predictive value of the PCR/ESI-MS in such a neonatal population. We analysed 114 samples over 14months. The median age and weight were 32weeks+3days and 1840g, respectively. Two patients had negative PCR/ESI-MS results, but positive blood cultures. Overall, the negative predictive value was 98% (95%CI: 92% to 100%). Based on these results, PCR/ESI-MS analysis of blood samples of neonates with suspected sepsis appears to have a very good negative predictive value when compared to blood cultures as gold standard. This novel test might allow for early reassessment of the need for antibiotics. Copyright © 2017 Elsevier B.V. All rights reserved.
Survival of Plasmodium falciparum in human blood during refrigeration.
Chattopadhyay, Rana; Majam, Victoria F; Kumar, Sanjai
2011-03-01
Transfusion-transmitted malaria remains a serious concern for blood safety. Viable Plasmodium parasites must be present in human blood to transmit malaria, but their survival in blood over time stored under refrigeration has never been carefully investigated. We spiked leukoreduced normal human blood with Plasmodium falciparum (3D7 strain) asexual ring-stage parasites and stored it at 4 °C for 28 days, taking samples at different days intervals. We evaluated the samples for parasitemia by blood film microscopy and by culturing red blood cells (RBCs) to allow further development of parasites. We observed a significant reduction in parasitemia (0.5% vs. 0.12%) after only 1 day in storage at 4 °C. Thereafter, reduction in parasitemia was relatively gradual. Microscopically detectable parasites were present even after 28 days of storage. However, after storing for more than 14 days at 4 °C, parasites no longer replicated when cultured in vitro. Although the storage of asexual blood-stage P. falciparum parasites at 4 °C is detrimental to their survival (a 7.1-fold reduction in parasitemia after 14 days in storage), parasites remained microscopically detectable for 28 days, the end time point of our study. Further in vitro and in vivo studies will be needed to confirm loss of viability of P. falciparum after 14 days in storage, but our initial efforts repeatedly failed to show maturation and development of the parasites in cultured RBCs after that time. © 2010 American Association of Blood Banks.
Lindholt; Vammen; Henneberg; Fasting
1999-05-01
BACKGROUND: The potential correlation between chronic infection with Chlamydia pneumoniae and the progression of small abdominal aortic aneurysms (AAAs) and lower limb atherosclerosis was studied. METHODS: Mass screening for AAA was carried out in outdoor clinics at all hospitals in the county. Some 139 men (aged 65-73 years) with a 3.0-4.9-cm AAA were followed prospectively for 1-3 (mean 2.7) years. Initially, an interview and examination was performed, and blood samples were taken. RESULTS: Some 62 per cent (53-71 per cent) had an immunoglobulin (Ig) A level of 40 or more, or an IgG level of 64 or above. Some 83 per cent (74-93 per cent) had an IgA level of 20 or more, or an IgG level of 32 or more. Men with an IgA level of 20 or more had 51 per cent greater AAA expansion and men with an IgA level of 40 or above had 24 per cent more expansion. An IgA level of 20 or more, or IgA of 40 or greater, were significant independent predictors of AAA expansion adjusted for age, smoking, initial AAA size, steroid treatment, diastolic blood pressure, pulmonary function and other plasma factors. The ankle blood pressure index (ABI) of the IgA-seropositive men decreased 11 per cent, while the ABI decreased by 5 per cent among IgA-seronegative men (P < 0.05). The significant difference persisted after adjusting for age, smoking, initial systolic ankle blood pressure, initial brachial systolic or diastolic blood pressure, but disappeared after adjusting for low-density lipoprotein (LDL) levels. CONCLUSION: A high proportion of men with a small AAA have signs of chronic C. pneumoniae infection. The progression of AAAs and lower limb atherosclerosis seems to be correlated to chronic infection with C. pneumoniae.
Reamer, Lisa A; Haller, Rachel L; Thiele, Erica J; Freeman, Hani D; Lambeth, Susan P; Schapiro, Steven J
2014-01-01
Type 2 diabetes can be a problem for captive chimpanzees. Accurate blood glucose (BG) readings are necessary to monitor and treat this disease. Thus, obtaining voluntary samples from primates through positive reinforcement training (PRT) is critical. The current study assessed the voluntary participation of 123 chimpanzees in BG sampling and investigated factors that may contribute to individual success. All subjects participate in regular PRT sessions as part of a comprehensive behavioral management program. Basic steps involved in obtaining BG values include: voluntarily presenting a finger/toe; allowing digit disinfection; holding for the lancet device; and allowing blood collection onto a glucometer test strip for analysis. We recorded the level of participation (none, partial, or complete) when each chimpanzee was first asked to perform the testing procedure. Nearly 30% of subjects allowed the entire procedure in one session, without any prior specific training for the target behavior. Factors that affected this initial successful BG testing included sex, personality (chimpanzees rated higher on the factor "openness" were more likely to participate with BG testing), and past training performance for "present-for-injection" (chimpanzees that presented for their most recent anesthetic injection were more likely to participate). Neither age, rearing history, time since most recent anesthetic event nor social group size significantly affected initial training success. These results have important implications for captive management and training program success, underlining individual differences in training aptitude and the need for developing individual management plans in order to provide optimal care and treatment for diabetic chimpanzees in captivity. © 2014 Wiley Periodicals, Inc.
Carey, Roger Neill; Jani, Chinu; Johnson, Curtis; Pearce, Jim; Hui-Ng, Patricia; Lacson, Eduardo
2016-09-07
Plasma samples collected in tubes containing separator gels have replaced serum samples for most chemistry tests in many hospital and commercial laboratories. Use of plasma samples for blood tests in the dialysis population eliminates delays in sample processing while waiting for clotting to complete, laboratory technical issues associated with fibrin formation, repeat sample collection, and patient care issues caused by delay of results because of incompletely clotted specimens. Additionally, a larger volume of plasma is produced than serum for the same amount of blood collected. Plasma samples are also acceptable for most chemical tests involved in the care of patients with ESRD. This information becomes very important when United States regulatory requirements for ESRD inadvertently limit the type of sample that can be used for government reporting, quality assessment, and value-based payment initiatives. In this narrative, we summarize the renal community experience and how the subsequent resolution of the acceptability of phosphorus levels measured from serum and plasma samples may have significant implications in the country's continued development of a value-based Medicare ESRD Quality Incentive Program. Copyright © 2016 by the American Society of Nephrology.
Pediatric lead poisoning from folk prescription for treating epilepsy.
Ying, Xiao-Lan; Xu, Jian; Markowitz, Morri; Yan, Chong-Huai
2016-10-01
A case of lead poisoning resulting from the ingestion of a folk remedy for treating epilepsy is reported. The initial blood lead concentration of this 6-y-old boy was 63.6μg/dl upon admission. He presented with abdominal pain, constipation, and irritability. The patient's liver function tests were significantly increased. Through chelation therapy, the blood lead concentration dropped markedly and clinical symptoms greatly improved. His blood and urine samples were collected for the kinetic analysis of lead elimination. Folk prescriptions for epilepsy should be considered as potential sources of lead intoxication. Lead poisoning should be taken into consideration for unknown causes of abdominal pain. Copyright © 2016. Published by Elsevier B.V.
Human (13)N-ammonia PET studies: the importance of measuring (13)N-ammonia metabolites in blood.
Keiding, Susanne; Sørensen, Michael; Munk, Ole Lajord; Bender, Dirk
2010-03-01
Dynamic (13)N-ammonia PET is used to assess ammonia metabolism in brain, liver and muscle based on kinetic modeling of metabolic pathways, using arterial blood (13)N-ammonia as input function. Rosenspire et al. (1990) introduced a solid phase extraction procedure for fractionation of (13)N-content in blood into (13)N-ammonia, (13)N-urea, (13)N-glutamine and (13)N-glutamate. Due to a radioactive half-life for (13)N of 10 min, the procedure is not suitable for blood samples taken beyond 5-7 min after tracer injection. By modifying Rosenspire's method, we established a method enabling analysis of up to 10 blood samples in the course of 30 min. The modified procedure was validated by HPLC and by 30-min reproducibility studies in humans examined by duplicate (13)N-ammonia injections with a 60-min interval. Blood data from a (13)N-ammonia brain PET study (from Keiding et al. 2006) showed: (1) time courses of (13)N-ammonia fractions could be described adequately by double exponential functions; (2) metabolic conversion of (13)N-ammonia to (13)N-metabolites were in the order: healthy subjects > cirrhotic patients without HE > cirrhotic patients with HE; (3) kinetics of initial tracer distribution in tissue can be assessed by using total (13)N-concentration in blood as input function, whereas assessment of metabolic processes requires (13)N-ammonia measurements.
Biomonitoring data can help inform the development and calibration of high-throughput exposure modeling for use in prioritization and risk evaluation. A pilot project was conducted to evaluate the feasibility of using pooled banked blood samples to generate initial data on popul...
Wang, Yin-Ruei; Liu, Sheng-Fu; Shen, You-Cheng; Chen, Chien-Li; Huang, Chine-Ning; Pan, Tzu-Ming; Wang, Chin-Kun
2017-04-01
Diabetes is the fourth major cause of death in Taiwan. High blood glucose can lead to macrovascular diseases, small vessel diseases (retinopathy, kidney disease), and neuropathy. This study aimed to investigate whether Monascus-fermented products (ANKASCIN 568 plus) can regulate blood glucose and blood lipids. This study enrolled 39 patients with a fasting blood glucose level between 100 mg/dL and 180 mg/dL, and a glycated hemoglobin (HbA1c) level of <9%. All patients were randomly divided into placebo (n=20) and experimental (n=19) groups. Each patient received two placebo capsules (maltodextrin) or ANKASCIN 568 plus capsules daily for 12 weeks. The patients were screened during follow-up 4 weeks after the administration of sample or placebo had been discontinued. Blood and urine samples were collected at the initial, 6 th week, 12 th week, and 16 th week. The anthropometric indicators of blood pressure, fasting plasma glucose level, postprandial plasma glucose level, insulin level, insulin resistance, blood lipid changes, and liver, kidney, and thyroid function indices were measured. After 6 weeks, changes in fasting blood glucose, low-density lipoprotein cholesterol (LDL-C), and total cholesterol (TC) levels showed that ANKASCIN 568 plus had a more favorable effect than the placebo. Compared to baseline, a statistically significant decrease of 8.5%, 10.3%, and 7.5% was observed in fasting blood glucose, LDL-C and, TC levels, respectively (p<0.05 for all pairs). Therefore, ANKASCIN 568 plus produced by Monascus purpureus NTU 568 fermentation may be a potentially useful agent for the regulation of blood glucose and blood lipids and for treatment of coronary artery diseases. Copyright © 2016. Published by Elsevier B.V.
Mean Blood Pressure Difference among Adolescents Based on Dyssomnia Types.
Sembiring, Krisnarta; Ramayani, Oke Rina; Lubis, Munar
2018-02-15
Dyssomnia is the most frequent sleep disturbance and associated with increased blood pressure. There has been no study determining the difference in mean blood pressure based on dyssomnia types among adolescents. To determine the difference in mean blood pressure among adolescents based on dyssomnia types. Cross-sectional study was conducted in SMP Negeri 1 Muara Batang Gadis in April 2016. Samples were students having sleep disturbance based on Sleep Disturbance Scale for Children (SDSC) questionnaire. Stature and blood pressure data were collected along with demographic data and sleep disorder questionnaire. Analyses were done with Kruskal-Wallis test and logistic regression. P - value < 0.05 was considered significant. Seventy-six samples were obtained with mean age 13.9 (SD 1.14) years - old. Dyssomnia proportion and hypertension were 72/76 and 20/76 respectively. Mean systolic (SBP) and diastolic blood pressure (DBP) was 111.1 (SD 16.46) mmHg and 70.3 (SD 11.98) mmHg respectively. Mean SDSC score was 49.7 (SD 8.96), and the most frequent dyssomnia type was disorders of initiating and maintaining sleep. Age and sex were not the risk factors of hypertension in dyssomnia. There was a significant difference in mean SBP (P = 0.006) and DBP (P = 0.022) based on dyssomnia types. Combination dyssomnia type had the highest mean blood pressure among dyssomnia types. There is a significant difference in mean blood pressure among adolescents based on dyssomnia types.
Gutierrez, Jean L; Bowden, Rodney G; Willoughby, Darryn S
2016-01-01
Cassia cinnamon has been suggested to lower blood glucose (BG) and serum insulin (SI) due to an improvement in insulin resistance (IR) and sensitivity (IS). This study compared the effects Cassia cinnamon had on calculated IR and IS values and BG and SI in response to an oral glucose tolerance test (OGTT) in young, sedentary, and obese women. On three separate days, 10 women had a fasted venous blood sample obtained. Participants were given 5 g of encapsulated placebo (PLC) or 5 g of encapsulated Cassia cinnamon bark (CASS). Three hours after the initial blood sample, another blood sample was obtained to calculate values for IS and IR. The participants then completed an OGTT by consuming a 75 g glucose solution. Blood was obtained 30, 60, 90, and 120 min following glucose ingestion. IS and IR were not significantly different between placebo and Cassia (p > .05). The peak BG concentration in response to the OGTT was significantly lower at the 30 min time point for CASS, as compared to PLC (140 ± 5.8 and 156 ± 5.2 mg/dL, p = .025); however, there was no significant difference between treatments for SI (p > .05). The area-under-the-curve responses for BG and SI were not significantly different between PLC and CASS (p > .05). This study suggests that a 5 g dose of Cassia cinnamon may reduce the peak BG response and improve glucose tolerance following an OGTT, but with no improvement in IS and IR in young, sedentary, obese women.
Ryan Clarke, P; Frey, Rebecca K; Rhyan, Jack C; McCollum, Matt P; Nol, Pauline; Aune, Keith
2014-03-01
OBJECTIVE--To determine the feasibility of qualifying individuals or groups of Yellowstone National Park bison as free from brucellosis. DESIGN--Cohort study. SAMPLE--Serum, blood, and various samples from live bison and tissues taken at necropsy from 214 bison over 7 years. PROCEDURES--Blood was collected from bison every 30 to 45 days for serologic tests and microbiological culture of blood for Brucella abortus. Seropositive bison were euthanized until all remaining bison had 2 consecutive negative test results. Half the seronegative bison were randomly euthanized, and tissues were collected for bacteriologic culture. The remaining seronegative bison were bred, and blood was tested at least twice per year. Cow-calf pairs were sampled immediately after calving and 6 months after calving for evidence of B abortus. RESULTS--Post-enrollment serial testing for B abortus antibodies revealed no bison that seroconverted after 205 days (first cohort) and 180 days (second cohort). During initial serial testing, 85% of bison seroconverted within 120 days after removal from the infected population. Brucella abortus was not cultured from any euthanized seronegative bison (0/88). After parturition, no cows or calves had a positive test result for B abortus antibodies, nor was B abortus cultured from any samples. CONCLUSIONS AND CLINICAL RELEVANCE--Results suggested it is feasible to qualify brucellosis-free bison from an infected herd following quarantine procedures as published in the USDA APHIS brucellosis eradication uniform methods and rules. Latent infection was not detected in this sample of bison when applying the USDA APHIS quarantine protocol.
Impact of Educational Activities in Reducing Pre-Analytical Laboratory Errors
Al-Ghaithi, Hamed; Pathare, Anil; Al-Mamari, Sahimah; Villacrucis, Rodrigo; Fawaz, Naglaa; Alkindi, Salam
2017-01-01
Objectives Pre-analytic errors during diagnostic laboratory investigations can lead to increased patient morbidity and mortality. This study aimed to ascertain the effect of educational nursing activities on the incidence of pre-analytical errors resulting in non-conforming blood samples. Methods This study was conducted between January 2008 and December 2015. All specimens received at the Haematology Laboratory of the Sultan Qaboos University Hospital, Muscat, Oman, during this period were prospectively collected and analysed. Similar data from 2007 were collected retrospectively and used as a baseline for comparison. Non-conforming samples were defined as either clotted samples, haemolysed samples, use of the wrong anticoagulant, insufficient quantities of blood collected, incorrect/lack of labelling on a sample or lack of delivery of a sample in spite of a sample request. From 2008 onwards, multiple educational training activities directed at the hospital nursing staff and nursing students primarily responsible for blood collection were implemented on a regular basis. Results After initiating corrective measures in 2008, a progressive reduction in the percentage of non-conforming samples was observed from 2009 onwards. Despite a 127.84% increase in the total number of specimens received, there was a significant reduction in non-conforming samples from 0.29% in 2007 to 0.07% in 2015, resulting in an improvement of 75.86% (P <0.050). In particular, specimen identification errors decreased by 0.056%, with a 96.55% improvement. Conclusion Targeted educational activities directed primarily towards hospital nursing staff had a positive impact on the quality of laboratory specimens by significantly reducing pre-analytical errors. PMID:29062553
Kalliokoski, Otto; Sørensen, Dorte B; Hau, Jann; Abelson, Klas S P
2014-01-01
Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters measured, and expressed less anxious behavior. We conclude that repeated blood sampling by automated blood sampling and from the tail vein is less stressful than cheek blood sampling. The choice between automated blood sampling and tail blood sampling should be based on the study requirements, the resources of the laboratory and skills of the staff. PMID:24958546
Médaille, C; Briend-Marchal, A; Braun, J P
2006-03-01
Most hematologic analyses are performed within a short time of blood sampling, but samples collected at the end of a week may have to be stored for up to 2 days. The stability of hematologic constituents is poorly documented. The objective of this study was to compare the results of RBC, WBC and platelet counts, hemoglobin (Hgb) concentration, and MCV before and after storage of canine blood at room temperature for 24 and 48 hours. One hundred fifty-two K3-EDTA canine blood specimens from 2 veterinary hospitals were analyzed within 4 hours of collection, then 24 and 48 hours later with a Coulter T540 hematology analyzer. Results were compared by Passing-Bablock agreement, difference plots, and according to their classification as normal or abnormal based on reference intervals. RBC count and Hgb concentration were stable for the duration of the study. Differences in WBC and platelet counts varied with the specimen, independently of the initial value. MCV increased consistently over the 2 days. However, only a few results were misclassified. Whole blood specimens stored for up to 2 days at room temperature are suitable for cell counts and Hgb measurement. However, potential variations have to be known to avoid misinterpretations, especially near the decision limits.
Aging: a portrait from gene expression profile in blood cells.
Calabria, Elisa; Mazza, Emilia Maria Cristina; Dyar, Kenneth Allen; Pogliaghi, Silvia; Bruseghini, Paolo; Morandi, Carlo; Salvagno, Gian Luca; Gelati, Matteo; Guidi, Gian Cesare; Bicciato, Silvio; Schiaffino, Stefano; Schena, Federico; Capelli, Carlo
2016-08-01
The availability of reliable biomarkers of aging is important not only to monitor the effect of interventions and predict the timing of pathologies associated with aging but also to understand the mechanisms and devise appropriate countermeasures. Blood cells provide an easily available tissue and gene expression profiles from whole blood samples appear to mirror disease states and some aspects of the aging process itself. We report here a microarray analysis of whole blood samples from two cohorts of healthy adult and elderly subjects, aged 43±3 and 68±4 years, respectively, to monitor gene expression changes in the initial phase of the senescence process. A number of significant changes were found in the elderly compared to the adult group, including decreased levels of transcripts coding for components of the mitochondrial respiratory chain, which correlate with a parallel decline in the maximum rate of oxygen consumption (VO2max), as monitored in the same subjects. In addition, blood cells show age-related changes in the expression of several markers of immunosenescence, inflammation and oxidative stress. These findings support the notion that the immune system has a major role in tissue homeostasis and repair, which appears to be impaired since early stages of the aging process.
Ion mobility analysis of lipoproteins
Benner, W Henry [Danville, CA; Krauss, Ronald M [Berkeley, CA; Blanche, Patricia J [Berkeley, CA
2007-08-21
A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.
Aerosol preparation of intact lipoproteins
Benner, W Henry [Danville, CA; Krauss, Ronald M [Berkeley, CA; Blanche, Patricia J [Berkeley, CA
2012-01-17
A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.
Armando García-Miranda, L; Contreras, I; Estrada, J A
2014-04-01
To determine reference values for full blood count parameters in a population of children 8 to 12 years old, living at an altitude of 2760 m above sea level. Our sample consisted of 102 individuals on whom a full blood count was performed. The parameters included: total number of red blood cells, platelets, white cells, and a differential count (millions/μl and %) of neutrophils, lymphocytes, monocytes, eosinophils and basophils. Additionally, we obtained values for hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, concentration of corpuscular hemoglobin and red blood cell distribution width. The results were statistically analyzed with a non-parametric test, to divide the sample in quartiles and obtain the lower and upper limits for our intervals. Moreover, the values for the intervals obtained from this analysis were compared to intervals obtained estimating+- 2 standard deviations above and below from our mean values. Our results showed significant differences compared to normal interval values reported for the adult Mexican population in most of the parameters studied. The full blood count is an important laboratory test used routinely for the initial assessment of a patient. Values of full blood counts in healthy individuals vary according to gender, age and geographic location; therefore, each population should have its own reference values. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Flower, Jennifer E.; Norton, Terry M.; Andrews, Kimberly M.; Nelson, Steven E.; Parker, Clare E.; Romero, L. Michael; Mitchell, Mark A.
2015-01-01
The evaluation of hormonal responses to stress in reptiles relies on acquisition of baseline corticosterone concentrations; however, the stress associated with the restraint needed to collect the blood samples can affect the results. The purpose of this study was to determine a time limit for the collection of blood samples to evaluate baseline corticosterone, haematological and biochemical results in nesting (n = 11) and rehabilitating (n = 16) loggerhead sea turtles (Caretta caretta). Blood samples were collected from the dorsal cervical sinus of each turtle immediately after touching the animal (t0; 0–3 min) and 3 (t3; 3–6 min), 6 (t6; 6–9 min; nesting turtles only), 10 (t10; 10–13 min) and 30 min (t30; rehabilitating turtles only) after the initial hands-on time. Consistent between the rehabilitating and nesting turtles, there was a subtle yet significant increase in white blood cell counts over time. Despite the fact that white blood cell counts increased during the sampling period, there was no direct correlation between white blood cell count and corticosterone in the sampled turtles. In the nesting turtles, significant elevations in corticosterone were noted between t0 and t3 (P = 0.014) and between t0 and t6 (P = 0.022). Values at t10 were not significantly different from those at t0 (P = 0.102); however, there was a trend for the corticosterone values to continue to increase. These results suggest that sampling of nesting loggerhead sea turtles within 3 min of handling will provide baseline corticosterone concentrations in their natural environment. Significant elevations in corticosterone were also noted in the rehabilitating loggerhead sea turtles between t0 and t10 (P = 0.02) and between t0 and t30 of sampling (P = 0.0001). These results suggest that sampling of loggerhead sea turtles within 6 min of handling should provide baseline corticosterone concentrations in a rehabilitation setting. The delay in the corticosterone response noted in the rehabilitating turtles may be associated with the daily contact (visual or direct) they have with their human caretakers. PMID:27293688
Garssen, Johan; Sandalova, Elena
2016-01-01
Vaccination, designed to trigger a protective immune response against infection, is a trigger for mild inflammatory responses. Vaccination studies can address the question of inflammation initiation, levels, and resolution as well as its regulation for respective studied pathogens. Such studies largely based on analyzing the blood components including specific antibodies and cytokines were usually constrained by number of participants and volume of collected blood sample. Hence, blood-based studies may not be able to cover the full dynamic range of inflammation responses induced by vaccination. In this review, the potential of using saliva in addition to blood for studying the kinetics of inflammatory response studies was assessed. Saliva sampling is noninvasive and has a great potential to be used for studies aimed at analysing the magnitude, time course, and variance in immune responses, including inflammation after vaccination. Based on a literature survey of inflammatory biomarkers that can be determined in saliva and an analysis of how these biomarkers could help to understand the mechanisms and dynamics of immune reactivity and inflammation, we propose that the saliva-based approach might have potential to add substantial value to clinical studies, particularly in vulnerable populations such as infants, toddlers, and ill individuals. PMID:27022211
Lead excretion in milk of accidentally exposed dairy cattle.
Bischoff, Karyn; Higgins, William; Thompson, Belinda; Ebel, Joseph G
2014-01-01
Lead (Pb) exposure in dairy cattle is associated with economic losses due to mortality and treatment costs, but with production animals there is also risk to the human food chain. The first objective of this study was to quantify the Pb concentration in milk from Pb-exposed cattle. The second objective was to correlate blood and milk Pb concentrations from individual cows. The third objective was long-term monitoring to determine the duration of milk contamination after exposure ceased. A dairy herd of more than 100 cows was accidentally exposed to Pb-contaminated feed. Milk and blood were collected for Pb analysis. Serial collection of milk samples continued for 2.5 years. The initial concentration of Pb in bulk tank milk was 0.0999 mg l⁻¹. The highest milk Pb concentration from an individual cow was 0.4657 mg l⁻¹ and the highest blood Pb concentration was 1.216 mg l⁻¹. One milk sample collected at the end of the study (day 922) contained 0.0117 mg Pb l⁻¹ of Pb. The calculated relationship between milk (y) and blood (x) Pb concentration was ln(y) = 3.4(x) - 2.21 (R² = 0.98).
Springer, Jan; White, P Lewis; Hamilton, Shanna; Michel, Denise; Barnes, Rosemary A; Einsele, Hermann; Löffler, Juergen
2016-03-01
Standardized methodologies for the molecular detection of invasive aspergillosis (IA) have been established by the European Aspergillus PCR Initiative for the testing of whole blood, serum, and plasma. While some comparison of the performance of Aspergillus PCR when testing these different sample types has been performed, no single study has evaluated all three using the recommended protocols. Standardized Aspergillus PCR was performed on 423 whole-blood pellets (WBP), 583 plasma samples, and 419 serum samples obtained from hematology patients according to the recommendations. This analysis formed a bicenter retrospective anonymous case-control study, with diagnosis according to the revised European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group and National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) consensus definitions (11 probable cases and 36 controls). Values for clinical performance using individual and combined samples were calculated. For all samples, PCR positivity was significantly associated with cases of IA (for plasma, P = 0.0019; for serum, P = 0.0049; and for WBP, P = 0.0089). Plasma PCR generated the highest sensitivity (91%); the sensitivities for serum and WBP PCR were 80% and 55%, respectively. The highest specificity was achieved when testing WBP (96%), which was significantly superior to the specificities achieved when testing serum (69%, P = 0.0238) and plasma (53%, P = 0.0002). No cases were PCR negative in all specimen types, and no controls were PCR positive in all specimens. This study confirms that Aspergillus PCR testing of plasma provides robust performance while utilizing commercial automated DNA extraction processes. Combining PCR testing of different blood fractions allows IA to be both confidently diagnosed and excluded. A requirement for multiple PCR-positive plasma samples provides similar diagnostic utility and is technically less demanding. Time to diagnosis may be enhanced by testing multiple contemporaneously obtained sample types. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Dosimetric and microdosimetric analyses for blood exposed to reactor-derived thermal neutrons.
Ali, F; Atanackovic, J; Boyer, C; Festarini, A; Kildea, J; Paterson, L C; Rogge, R; Stuart, M; Richardson, R B
2018-06-06
Thermal neutrons are found in reactor, radiotherapy, aircraft, and space environments. The purpose of this study was to characterise the dosimetry and microdosimetry of thermal neutron exposures, using three simulation codes, as a precursor to quantitative radiobiological studies using blood samples. An irradiation line was designed employing a pyrolytic graphite crystal or-alternatively-a super mirror to expose blood samples to thermal neutrons from the National Research Universal reactor to determine radiobiological parameters. The crystal was used when assessing the relative biological effectiveness for dicentric chromosome aberrations, and other biomarkers, in lymphocytes over a low absorbed dose range of 1.2-14 mGy. Higher exposures using a super mirror will allow the additional quantification of mitochondrial responses. The physical size of the thermal neutron fields and their respective wavelength distribution was determined using the McStas Monte Carlo code. Spinning the blood samples produced a spatially uniform absorbed dose as determined from Monte Carlo N-Particle version 6 simulations. The major part (71%) of the total absorbed dose to blood was determined to be from the 14 N(n,p) 14 C reaction and the remainder from the 1 H(n,γ) 2 H reaction. Previous radiobiological experiments at Canadian Nuclear Laboratories involving thermal neutron irradiation of blood yielded a relative biological effectiveness of 26 ± 7. Using the Particle and Heavy Ion Transport Code System, a similar value of ∼19 for the quality factor of thermal neutrons initiating the 14 N(n,p) 14 C reaction in soft tissue was determined by microdosimetric simulations. This calculated quality factor is of similar high value to the experimentally-derived relative biological effectiveness, and indicates the potential of thermal neutrons to induce deleterious health effects in superficial organs such as cataracts of the eye lens.
Routine blood cultures in the management of pyelonephritis in pregnancy for improving outcomes.
Gomi, Harumi; Goto, Yoshihito; Laopaiboon, Malinee; Usui, Rie; Mori, Rintaro
2015-02-13
Pyelonephritis is a type of urinary tract infection (UTI) that affects the upper urinary tract and kidneys, and is one of the most common conditions for hospitalisation among pregnant women, aside from delivery. Samples of urine and blood are obtained and used for cultures as part of the diagnosis and management of the condition. Acute pyelonephritis requires hospitalisation with intravenous administration of antimicrobial agents. Several studies have questioned the necessity of obtaining blood cultures in addition to urine cultures, citing cost and questioning whether blood testing is superfluous. Pregnant women with bacteraemia require a change in the initial empirical treatment based on the blood culture. However, these cases are not common, and represent approximately 15% to 20% of cases. It is unclear whether blood cultures are essential for the effective management of the condition. To assess the effectiveness of routine blood cultures to improve health outcomes in the management of pyelonephritis in pregnant women. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register without language or date restrictions (31 December 2014). Randomised controlled trials and quasi-randomised trials comparing outcomes among pregnant women with pyelonephritis who received initial management with or without blood cultures. Cluster-randomised trials were eligible for inclusion in this review but none were identified. Clinical trials using a cross-over design were not eligible for inclusion. Two review authors independently assessed one trial report for inclusion. We identified one trial report but this was excluded. No clinical trials met the inclusion criteria for this review. There are no large-scale randomised controlled trials to assess outcomes in the management of pyelonephritis in pregnancy with or without blood cultures. Randomised controlled trials are needed to evaluate the effectiveness of managing pyelonephritis in pregnant women with or without blood cultures, and to assess any adverse outcomes as well as the cost-effectiveness of excluding blood cultures from treatment.
Human Finger-Prick Induced Pluripotent Stem Cells Facilitate the Development of Stem Cell Banking
Tan, Hong-Kee; Toh, Cheng-Xu Delon; Ma, Dongrui; Yang, Binxia; Liu, Tong Ming; Lu, Jun; Wong, Chee-Wai; Tan, Tze-Kai; Li, Hu; Syn, Christopher; Tan, Eng-Lee; Lim, Bing; Lim, Yoon-Pin; Cook, Stuart A.
2014-01-01
Induced pluripotent stem cells (iPSCs) derived from somatic cells of patients can be a good model for studying human diseases and for future therapeutic regenerative medicine. Current initiatives to establish human iPSC (hiPSC) banking face challenges in recruiting large numbers of donors with diverse diseased, genetic, and phenotypic representations. In this study, we describe the efficient derivation of transgene-free hiPSCs from human finger-prick blood. Finger-prick sample collection can be performed on a “do-it-yourself” basis by donors and sent to the hiPSC facility for reprogramming. We show that single-drop volumes of finger-prick samples are sufficient for performing cellular reprogramming, DNA sequencing, and blood serotyping in parallel. Our novel strategy has the potential to facilitate the development of large-scale hiPSC banking worldwide. PMID:24646489
Computer-Aided Diagnosis Of Leukemic Blood Cells
NASA Astrophysics Data System (ADS)
Gunter, U.; Harms, H.; Haucke, M.; Aus, H. M.; ter Meulen, V.
1982-11-01
In a first clinical test, computer programs are being used to diagnose leukemias. The data collected include blood samples from patients suffering from acute myelomonocytic-, acute monocytic- and acute promyelocytic, myeloblastic, prolymphocytic, chronic lymphocytic leukemias and leukemic transformed immunocytoma. The proper differentiation of the leukemic cells is essential because the therapy depends on the type of leukemia. The algorithms analyse the fine chromatin texture and distribution in the nuclei as well as size and shape parameters from the cells and nuclei. Cells with similar nuclei from different leukemias can be distinguished from each other by analyzing the cell cytoplasm images. Recognition of these subtle differences in the cells require an image sampling rate of 15-30 pixel/micron. The results for the entire data set correlate directly to established hematological parameters and support the previously published initial training set .
Combinatorial Screening Of Inorganic And Organometallic Materials
Li, Yi , Li, Jing , Britton, Ted W.
2002-06-25
A method for differentiating and enumerating nucleated red blood cells in a blood sample is described. The method includes the steps of lysing red blood cells of a blood sample with a lytic reagent, measuring nucleated blood cells by DC impedance measurement in a non-focused flow aperture, differentiating nucleated red blood cells from other cell types, and reporting nucleated red blood cells in the blood sample. The method further includes subtracting nucleated red blood cells and other interference materials from the count of remaining blood cells, and reporting a corrected white blood cell count of the blood sample. Additionally, the method further includes measuring spectrophotometric absorbance of the sample mixture at a predetermined wavelength of a hemoglobin chromogen formed upon lysing the blood sample, and reporting hemoglobin concentration of the blood sample.
Child, D F; Williams, C P
1982-06-01
Diabetic control was assessed in 82 established insulin-dependent diabetics using a microcapillary system for home preprandial blood glucose sampling. At initial assessment control in the majority (62%) was found to be unsatisfactory (at least 1 preprandial blood glucose greater than 13.0 mmol/l or frequent and severe hypoglycaemia). Sixty-three of these patients were assessed on more than one occasion. Only 24% were satisfactorily controlled at their first assessment, but this proportion had risen to 60% after 12 months. The ability of patients to perform unsupervised blood glucose levels using Ames Glucometers or BM-Glycemie 20-800 test strips was also assessed: 86% of the meter results were within one-third of the laboratory-based results, but there was evidence of bias towards the under-reading of higher glucose values using BM-Glycemie 20-800 test strips. Random blood glucose estimations performed in the diabetic clinic were of little value.
Anderson, Dudley G.; Clark, John L.
1974-01-01
From the spring of 1971 to September 1973, neighborhood surveys were conducted in 58 communities throughout the nation to determine whether children with confirmed elevated blood lead levels could be identified. Another purpose of these screenings was to assist communities in identifying children with elevated blood lead levels and thereby demonstrate to community officials that such children do exist in communities screened. The children screened were not a random sample. In those communities where the initial elevated blood levels were confirmed all but seven had one or more children requiring followup and/or treatment. Of those children screened, black children had an elevated rate about three times as great as nonblack children. With few exceptions, the homes in the neighborhoods had at least one interior surface with sufficient quantities of lead paint to be dangerous if the paint were ingested. PMID:4831146
Katsenos, Chrysostomos S; Antonopoulou, Anastasia N; Apostolidou, Efterpi N; Ioakeimidou, Aikaterini; Kalpakou, Georgia Th; Papanikolaou, Metaxia N; Pistiki, Aikaterini C; Mpalla, Margarita C; Paraschos, Michael D; Patrani, Maria A; Pratikaki, Maria E; Retsas, Theodoros A; Savva, Athina A; Vassiliagkou, Spyridoula D; Lekkou, Alexandra A; Dimopoulou, Ioanna; Routsi, Christina; Mandragos, Konstantinos E
2014-07-01
To investigate the impact of early initiation of hydrocortisone therapy on the clinical course of septic shock and on cytokine release. Prospective study in patients with septic shock treated with low doses of hydrocortisone. ICUs and general wards. Over a 2-year period, 170 patients with septic shock treated with low doses of hydrocortisone were enrolled. Blood was sampled from 34 patients for isolation of peripheral blood mononuclear cells and cytokine stimulation before and 24 hours after the start of hydrocortisone. None. After quartile analysis, patients were divided into those with early initiation of hydrocortisone (< 9 hr after vasopressors, n = 46) and those with late initiation of hydrocortisone (> 9 hr after vasopressors, n = 124). After adjusting for disease severity and type of infection, a protective effect of early hydrocortisone administration against unfavorable outcome was found (hazard ratio, 0.20; p = 0.012). Time of discontinuation of vasopressors was earlier among patients with initiation of hydrocortisone within 9 hours. Production of tumor necrosis factor-α was lower among patients who had had hydrocortisone early. In patients receiving hydrocortisone for septic shock, early initiation of treatment was associated with improved survival. This treatment was also associated with attenuated stimulation of tumor necrosis factor-α.
Stability of Phosphatidylethanol in Dry Blood Spot Cards.
Bakhireva, Ludmila N; Shrestha, Shikhar; Gutierrez, Hilda L; Berry, Mike; Schmitt, Cheryl; Sarangarm, Dusadee
2016-05-01
The analysis of phosphatidylethanol, a promising direct ethanol metabolite, in dry blood spots (PEth-DBS) is advantageous due to ease of storage, transportation and minimal invasiveness of capillary blood collection. One potential application of PEth-DBS is to confirm prenatal alcohol exposure in newborns suspected of FASD; however, stability of PEth-DBS is largely unknown. Phlebotomized samples from 31 adults with a history of alcoholism, admitted to the University of New Mexico Emergency Department, were analyzed for blood alcohol content and pipetted onto DBS cards (13 spots per patient). The first spot was analyzed within 2 weeks of collection for a baseline PEth; the remaining 12 spots were allocated into three temperature conditions (room temperature, 4°C, -80°C) for the repeated measures analysis. In addition, 5 newborn DBS samples with a baseline PEth>LOD were obtained from a prospective cohort at UNM and re-analyzed at 4 months after storage at -80°C. A mixed linear model was fitted to examine the effects of temperature, time and temperature-time interaction on PEth degradation over the first 9 months. The baseline PEth levels were 592.8 ± 86.7 ng/ml and 18.3 ± 4.8 ng/ml in adult and newborn samples, respectively. All DBS samples remained positive in successive samples in all temperature conditions. Results of mixed linear model demonstrated a significant effect of temperature (P < 0.001) on PEth degradation over 9 months. PEth-DBS appears to be relatively stable, especially when stored at lower temperatures. These initial results are encouraging and highlight the PEth-DBS potential in retrospective assessment of alcohol exposure. © The Author 2015. Medical Council on Alcohol and Oxford University Press. All rights reserved.
Stability of Phosphatidylethanol in Dry Blood Spot Cards
Bakhireva, Ludmila N.; Shrestha, Shikhar; Gutierrez, Hilda L.; Berry, Mike; Schmitt, Cheryl; Sarangarm, Dusadee
2016-01-01
Background The analysis of phosphatidylethanol, a promising direct ethanol metabolite, in dry blood spots (PEth-DBS) is advantageous due to ease of storage, transportation and minimal invasiveness of capillary blood collection. One potential application of PEth-DBS is to confirm prenatal alcohol exposure in newborns suspected of FASD; however, stability of PEth-DBS is largely unknown. Methods Phlebotomized samples from 31 adults with a history of alcoholism, admitted to the University of New Mexico Emergency Department, were analyzed for blood alcohol content and pipetted onto DBS cards (13 spots per patient). The first spot was analyzed within 2 weeks of collection for a baseline PEth; the remaining 12 spots were allocated into three temperature conditions (room temperature, 4°C, −80°C) for the repeated measures analysis. In addition, 5 newborn DBS samples with a baseline PEth>LOD were obtained from a prospective cohort at UNM and re-analyzed at 4 months after storage at −80°C. A mixed linear model was fitted to examine the effects of temperature, time and temperature–time interaction on PEth degradation over the first 9 months. Results The baseline PEth levels were 592.8 ± 86.7 ng/ml and 18.3 ± 4.8 ng/ml in adult and newborn samples, respectively. All DBS samples remained positive in successive samples in all temperature conditions. Results of mixed linear model demonstrated a significant effect of temperature (P < 0.001) on PEth degradation over 9 months. Conclusions PEth-DBS appears to be relatively stable, especially when stored at lower temperatures. These initial results are encouraging and highlight the PEth-DBS potential in retrospective assessment of alcohol exposure. PMID:26519350
Exploring the initial steps of the testing process: frequency and nature of pre-preanalytic errors.
Carraro, Paolo; Zago, Tatiana; Plebani, Mario
2012-03-01
Few data are available on the nature of errors in the so-called pre-preanalytic phase, the initial steps of the testing process. We therefore sought to evaluate pre-preanalytic errors using a study design that enabled us to observe the initial procedures performed in the ward, from the physician's test request to the delivery of specimens in the clinical laboratory. After a 1-week direct observational phase designed to identify the operating procedures followed in 3 clinical wards, we recorded all nonconformities and errors occurring over a 6-month period. Overall, the study considered 8547 test requests, for which 15 917 blood sample tubes were collected and 52 982 tests undertaken. No significant differences in error rates were found between the observational phase and the overall study period, but underfilling of coagulation tubes was found to occur more frequently in the direct observational phase (P = 0.043). In the overall study period, the frequency of errors was found to be particularly high regarding order transmission [29 916 parts per million (ppm)] and hemolysed samples (2537 ppm). The frequency of patient misidentification was 352 ppm, and the most frequent nonconformities were test requests recorded in the diary without the patient's name and failure to check the patient's identity at the time of blood draw. The data collected in our study confirm the relative frequency of pre-preanalytic errors and underline the need to consensually prepare and adopt effective standard operating procedures in the initial steps of laboratory testing and to monitor compliance with these procedures over time.
Garverick, H A; Harris, M N; Vogel-Bluel, R; Sampson, J D; Bader, J; Lamberson, W R; Spain, J N; Lucy, M C; Youngquist, R S
2013-01-01
Greater blood concentrations of nonesterified fatty acids (NEFA) and lesser blood concentrations of glucose are indicative of the normal process of nutrient partitioning that occurs in early postpartum dairy cows. The objective was to determine the relationship between blood NEFA and glucose concentrations and subsequent conception at first insemination in postpartum dairy cows. Holstein (n=148) and Guernsey (n=8) dairy cows were blood sampled at approximately d 10, 7, and 3 prepartum, on the day of calving and 3, 7, 14, and 21 d postpartum for measurement of NEFA and glucose concentrations. Serum and plasma were harvested and used for measurement of NEFA and glucose concentrations, respectively. Cows were given a presynchronization treatment (2 injections of PGF(2α) 14 d apart) with the second PGF(2α) injection occurring 14 d before the initiation of the timed AI (TAI) protocol. Blood for determination of progesterone concentrations was collected at each presynchronization injection and at the initiation of the TAI protocol that was used for first insemination (74±7 d postpartum). Cows were considered noncycling if serum progesterone concentrations at the 2 presynchronization PGF(2α) injections (d 37 and 51±7 postpartum) and at the initiation of the TAI protocol (d 65±7 postpartum) were ≤1 ng/mL, and there was no indication of ovulation or presence of a corpus luteum by ultrasound examination at the initiation of the TAI protocol. Pregnancy was determined at 33 d and again at 61 d after first insemination by using ultrasound. Across all days, serum NEFA and plasma glucose concentrations were not different between cows that ovulated before the initiation of the TAI program (cycling) compared with those that did not ovulate (noncycling). Serum NEFA concentrations, however, were less and plasma glucose concentrations were greater during the early postpartum period for cows that subsequently became pregnant at first insemination compared with those that failed to become pregnant. Logistic regressions were used to predict the probability of pregnancy based on NEFA and glucose concentrations from individual days. The prediction with the greatest likelihood ratio was for d 3 postpartum NEFA and glucose concentrations. Nutritional status during the early postpartum period (within 1 wk after calving), as indicated by blood NEFA and glucose concentrations, may affect subsequent fertility by a mechanism that is independent from interval to first ovulation. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Jun; Ninck, Markus; Gisler, Thomas
2009-07-01
Changes in scalp and cortical blood flow induced by voluntary hyperventilation are investigated by near-infrared diffusing-wave spectroscopy. The temporal intensity autocorrelation function g(2) (τ) of multiply scattered light is recorded from the forehead of subjects during hyperventilation. Blood flow within the sampled tissue volume is estimated by the mean decay rate of g(2) (τ) . Data measured from six subjects show that the pattern of the hemodynamic response during 50 s hyperventilation is rather complicated: within the first 10 s, in three subjects an initial increase in blood flow is observed; from 10 s to 20 s, the mean blood flow is smaller than its baseline value for all six subjects; for the duration from 20 s to 30 s, the blood flow increases again. However, after 30 s the change is not consistent across subjects. Further study on one of these subjects by using two receivers probing the blood flow in the cortex and in the superficial layers simultaneously, reveals that during hyperventilation, the direction of change in blood flow within the scalp is opposite to the one in the brain. This helps to understand the complicated hemodynamic response observed in our measurements.
Gakhar, Gunjan; Navarro, Vicente N.; Jurish, Madelyn; Lee, Guang Yu.; Tagawa, Scott T.; Akhtar, Naveed H.; Seandel, Marco; Geng, Yue; Liu, He; Bander, Neil H.; Giannakakou, Paraskevi; Christos, Paul J.; King, Michael R.; Nanus, David M.
2013-01-01
Hematogenous metastasis accounts for the majority of cancer-related deaths, yet the mechanism remains unclear. Circulating tumor cells (CTCs) in blood may employ different pathways to cross blood endothelial barrier and establish a metastatic niche. Several studies provide evidence that prostate cancer (PCa) cell tethering and rolling on microvascular endothelium via E-selectin/E-selectin ligand interactions under shear flow theoretically promote extravasation and contribute to the development of metastases. However, it is unknown if CTCs from PCa patients interact with E-selectin expressed on endothelium, initiating a route for tumor metastases. Here we report that CTCs derived from PCa patients showed interactions with E-selectin and E-selectin expressing endothelial cells. To examine E-selectin-mediated interactions of PCa cell lines and CTCs derived from metastatic PCa patients, we used fluorescently-labeled anti-prostate specific membrane antigen (PSMA) monoclonal antibody J591-488 which is internalized following cell-surface binding. We employed a microscale flow device consisting of E-selectin-coated microtubes and human umbilical vein endothelial cells (HUVECs) on parallel-plate flow chamber simulating vascular endothelium. We observed that J591-488 did not significantly alter the rolling behavior in PCa cells at shear stresses below 3 dyn/cm2. CTCs obtained from 31 PCa patient samples showed that CTCs tether and stably interact with E-selectin and E-selectin expressing HUVECs at physiological shear stress. Interestingly, samples collected during disease progression demonstrated significantly more CTC/E-selectin interactions than samples during times of therapeutic response (p=0.016). Analysis of the expression of sialyl Lewis X (sLex) in patient samples showed that a small subset comprising 1.9-18.8% of CTCs possess high sLex expression. Furthermore, E-selectin-mediated interactions between prostate CTCs and HUVECs were diminished in the presence of anti-E-selectin neutralizing antibody. CTC-Endothelial interactions provide a novel insight into potential adhesive mechanisms of prostate CTCs as a means to initiate metastasis. PMID:24386459
Fadeyi, Emmanuel A; Emery, Wanda; Simmons, Julie H; Jones, Mary Rose; Pomper, Gregory J
2017-10-01
The objective was to report a successful implementation of a blood cooler insert and tracking technology with educational initiatives and its effect on reducing red blood cell (RBC) wastage. The blood bank database was used to quantify and categorize total RBC units issued in blood coolers from January 2010 to December 2015 with and without the new inserts throughout the hospital. Radiofrequency identification tags were used with special software to monitor blood cooler tracking. An educational policy on how to handle the coolers was initiated. Data were gathered from the software that provided a real-time location monitoring of the blood coolers with inserts throughout the institution. The implementation of the blood cooler with inserts and tracking device reduced mean yearly RBC wastage by fourfold from 0.64% to 0.17% between 2010 and 2015. The conserved RBCs corresponded to a total cost savings of $167,844 during the 3-year postimplementation period. The implementation of new blood cooler inserts, tracking system, and educational initiatives substantially reduced the mean annual total RBC wastage. The cost to implement this initiative may be small if there is an existing institutional infrastructure to monitor and track hospital equipment into which the blood bank intervention can be adapted when compared to the cost of blood wastage. © 2017 AABB.
Shaw, Gregory; Lee-Barthel, Ann; Ross, Megan LR; Wang, Bing; Baar, Keith
2017-01-01
Background: Musculoskeletal injuries are the most common complaint in active populations. More than 50% of all injuries in sports can be classified as sprains, strains, ruptures, or breaks of musculoskeletal tissues. Nutritional and/or exercise interventions that increase collagen synthesis and strengthen these tissues could have an important effect on injury rates. Objective: This study was designed to determine whether gelatin supplementation could increase collagen synthesis. Design: Eight healthy male subjects completed a randomized, double-blinded, crossover-design study in which they consumed either 5 or 15 g of vitamin C–enriched gelatin or a placebo control. After the initial drink, blood was taken every 30 min to determine amino acid content in the blood. A larger blood sample was taken before and 1 h after consumption of gelatin for treatment of engineered ligaments. One hour after the initial supplement, the subjects completed 6 min of rope-skipping to stimulate collagen synthesis. This pattern of supplementation was repeated 3 times/d with ≥6 h between exercise bouts for 3 d. Blood was drawn before and 4, 24, 48, and 72 h after the first exercise bout for determination of amino-terminal propeptide of collagen I content. Results: Supplementation with increasing amounts of gelatin increased circulating glycine, proline, hydroxyproline, and hydroxylysine, peaking 1 h after the supplement was given. Engineered ligaments treated for 6 d with serum from samples collected before or 1 h after subjects consumed a placebo or 5 or 15 g gelatin showed increased collagen content and improved mechanics. Subjects who took 15 g gelatin 1 h before exercise showed double the amino-terminal propeptide of collagen I in their blood, indicating increased collagen synthesis. Conclusion: These data suggest that adding gelatin to an intermittent exercise program improves collagen synthesis and could play a beneficial role in injury prevention and tissue repair. This trial was registered at the Australian New Zealand Clinical Trials Registry as ACTRN12616001092482. PMID:27852613
Vitamin C-enriched gelatin supplementation before intermittent activity augments collagen synthesis.
Shaw, Gregory; Lee-Barthel, Ann; Ross, Megan Lr; Wang, Bing; Baar, Keith
2017-01-01
Musculoskeletal injuries are the most common complaint in active populations. More than 50% of all injuries in sports can be classified as sprains, strains, ruptures, or breaks of musculoskeletal tissues. Nutritional and/or exercise interventions that increase collagen synthesis and strengthen these tissues could have an important effect on injury rates. This study was designed to determine whether gelatin supplementation could increase collagen synthesis. Eight healthy male subjects completed a randomized, double-blinded, crossover-design study in which they consumed either 5 or 15 g of vitamin C-enriched gelatin or a placebo control. After the initial drink, blood was taken every 30 min to determine amino acid content in the blood. A larger blood sample was taken before and 1 h after consumption of gelatin for treatment of engineered ligaments. One hour after the initial supplement, the subjects completed 6 min of rope-skipping to stimulate collagen synthesis. This pattern of supplementation was repeated 3 times/d with ≥6 h between exercise bouts for 3 d. Blood was drawn before and 4, 24, 48, and 72 h after the first exercise bout for determination of amino-terminal propeptide of collagen I content. Supplementation with increasing amounts of gelatin increased circulating glycine, proline, hydroxyproline, and hydroxylysine, peaking 1 h after the supplement was given. Engineered ligaments treated for 6 d with serum from samples collected before or 1 h after subjects consumed a placebo or 5 or 15 g gelatin showed increased collagen content and improved mechanics. Subjects who took 15 g gelatin 1 h before exercise showed double the amino-terminal propeptide of collagen I in their blood, indicating increased collagen synthesis. These data suggest that adding gelatin to an intermittent exercise program improves collagen synthesis and could play a beneficial role in injury prevention and tissue repair. This trial was registered at the Australian New Zealand Clinical Trials Registry as ACTRN12616001092482. © 2017 American Society for Nutrition.
New Applications of the Human Whole Blood Pyrogen Assay (PyroCheck).
Fennrich; Wendel; Hartung
1999-01-01
The absence of pyrogens in injectable drugs is an indispensable safety control because contaminants causing fever pose a life-threatening risk to the patient resulting in the worst case in death by shock. When fever- inducing agents, i.e.pyrogens, come into contact with the immunocompetent cells in blood, these cells release mediators which transmit the fever signal to the thermoregulatory centre of the brain. The Phamocopoeia lists currently two test systems for pyrogenicity: 1. The in vivo rabbit pyrogen test which measures the fever reaction following injection of the sample to the animals. 2. The in vitro Limulus Amebocyte Lysate assay (LAL) which measures the coagulation in a lysate prepared from the blood of the horseshoe crab specifically initiated by endotoxins, i.e. cell wall components from Gram-negative bacteria. The new test presented here (PyroCheck) exploits the reaction of monocytes/macrophages for the detection of pyrogens: human whole blood taken from healthy volunteers is incubated in the presence of the test sample in any form, be it a solution, a powder or even solid material. Pyrogenic contaminations initiate the release of the "endogenous pyrogen" Interleukin-1beta determined by ELISA after a fixed incubation time. The technology presently listed in the Pharmacopoeia is limited to parenteralia (rabbit test: biologicals and pharmaceuticals, LAL: predominantly pharmaceuticals). In the EU Medical Devices Directive from 1995 the rabbit pyrogen test for medical products is in some cases requested. (in some cases LAL of an eluate from the device). However, pyrogen-testing needs to cover also innovative high-tech products such as medical devices (implants, medical plastic materials, dialysis machines), cellular therapies and species-specific agents (e.g. recombinant proteins). Here we report that the human blood test PyroCheck is suitable for testing filters in air quality control as well as for assessing medical devices and biocompatibility (dialysate fluid), i.e. that it can be extended to a wide spectrum of applications.
Saykin, Andrew J.; Shen, Li; Foroud, Tatiana M.; Potkin, Steven G.; Swaminathan, Shanker; Kim, Sungeun; Risacher, Shannon L.; Nho, Kwangsik; Huentelman, Matthew J.; Craig, David W.; Thompson, Paul M.; Stein, Jason L.; Moore, Jason H.; Farrer, Lindsay A.; Green, Robert C.; Bertram, Lars; Jack, Clifford R.; Weiner, Michael W.
2010-01-01
The role of the Alzheimer’s Disease Neuroimaging Initiative Genetics Core is to facilitate the investigation of genetic influences on disease onset and trajectory as reflected in structural, functional, and molecular imaging changes; fluid biomarkers; and cognitive status. Major goals include (1) blood sample processing, genotyping, and dissemination, (2) genome-wide association studies (GWAS) of longitudinal phenotypic data, and (3) providing a central resource, point of contact and planning group for genetics within Alzheimer’s Disease Neuroimaging Initiative. Genome-wide array data have been publicly released and updated, and several neuroimaging GWAS have recently been reported examining baseline magnetic resonance imaging measures as quantitative phenotypes. Other preliminary investigations include copy number variation in mild cognitive impairment and Alzheimer’s disease and GWAS of baseline cerebrospinal fluid biomarkers and longitudinal changes on magnetic resonance imaging. Blood collection for RNA studies is a new direction. Genetic studies of longitudinal phenotypes hold promise for elucidating disease mechanisms and risk, development of therapeutic strategies, and refining selection criteria for clinical trials. PMID:20451875
Determining the risk of cardiovascular disease using ion mobility of lipoproteins
Benner, W. Henry; Krauss, Ronald M.; Blanche, Patricia J.
2010-05-11
A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.
Amplification of Mitochondrial DNA for detection of Plasmodiumvivax in Balochistan.
Shahwani, Muhammad Naeem; Nisar, Samia; Aleem, Abdul; Panezai, Marina; Afridi, Sarwat; Malik, Shaukat Iqbal
2017-05-01
To access a new step using PCR to amplify the targeted mtDNA sequence for detecting specifically Plasmodium vivax and its co-infections, false positive and false negative results with Plasmodium falciparum. In this study we have standardized a new technical approach in which the target mitochondrial DNA sequence (mtDNA) was amplified by using a PCR technique as a tool to detect Plasmodium spp. Species specific primers were designed to hybridize with cytochrome c oxidase gene of P. vivax (cox I) and P. falciparum (cox III). Two hundred blood samples were collected on the basis of clinical symptoms which were initially examined through microscopic analysis after preparing Giemsa stained thick and thin blood smears. Afterwards genomic DNA was extracted from all samples and was then subjected to PCR amplification by using species specific primers and amplified segments were sequenced for confirmation of results. One-hundred and thirty-two blood samples were detected as positive for malaria by PCR, out of which 64 were found to be positive by PCR and 53 by both microscopy and PCR for P.vivax infection. Nine samples were found to be false negative, one P.vivax mono infection was declared as co infection by PCR and 3 samples identified as having P.falciparum gametes were confirmed as P.vivax by PCR amplification. Sensitivity and specificity were found to be 85% and 92% respectively. Results obtained through PCR method were comparatively better and reliable than microscopy.
Carobene, Anna; Strollo, Marta; Jonker, Niels; Barla, Gerhard; Bartlett, William A; Sandberg, Sverre; Sylte, Marit Sverresdotter; Røraas, Thomas; Sølvik, Una Ørvim; Fernandez-Calle, Pilar; Díaz-Garzón, Jorge; Tosato, Francesca; Plebani, Mario; Coşkun, Abdurrahman; Serteser, Mustafa; Unsal, Ibrahim; Ceriotti, Ferruccio
2016-10-01
Biological variation (BV) data have many fundamental applications in laboratory medicine. At the 1st Strategic Conference of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) the reliability and limitations of current BV data were discussed. The EFLM Working Group on Biological Variation is working to increase the quality of BV data by developing a European project to establish a biobank of samples from healthy subjects to be used to produce high quality BV data. The project involved six European laboratories (Milan, Italy; Bergen, Norway; Madrid, Spain; Padua, Italy; Istanbul, Turkey; Assen, The Netherlands). Blood samples were collected from 97 volunteers (44 men, aged 20-60 years; 43 women, aged 20-50 years; 10 women, aged 55-69 years). Initial subject inclusion required that participants completed an enrolment questionnaire to verify their health status. The volunteers provided blood specimens once per week for 10 weeks. A short questionnaire was completed and some laboratory tests were performed at each sampling consisting of blood collected under controlled conditions to provide serum, K2EDTA-plasma and citrated-plasma samples. Samples from six out of the 97 enroled subjects were discarded as a consequence of abnormal laboratory measurements. A biobank of 18,000 aliquots was established consisting of 120 aliquots of serum, 40 of EDTA-plasma, and 40 of citrated-plasma from each subject. The samples were stored at -80 °C. A biobank of well-characterised samples collected under controlled conditions has been established delivering a European resource to enable production of contemporary BV data.
Freeman, Christine M; Crudgington, Sean; Stolberg, Valerie R; Brown, Jeanette P; Sonstein, Joanne; Alexis, Neil E; Doerschuk, Claire M; Basta, Patricia V; Carretta, Elizabeth E; Couper, David J; Hastie, Annette T; Kaner, Robert J; O'Neal, Wanda K; Paine, Robert; Rennard, Stephen I; Shimbo, Daichi; Woodruff, Prescott G; Zeidler, Michelle; Curtis, Jeffrey L
2015-01-27
Subpopulations and Intermediate Outcomes in COPD Study (SPIROMICS) is a multi-center longitudinal, observational study to identify novel phenotypes and biomarkers of chronic obstructive pulmonary disease (COPD). In a subset of 300 subjects enrolled at six clinical centers, we are performing flow cytometric analyses of leukocytes from induced sputum, bronchoalveolar lavage (BAL) and peripheral blood. To minimize several sources of variability, we use a "just-in-time" design that permits immediate staining without pre-fixation of samples, followed by centralized analysis on a single instrument. The Immunophenotyping Core prepares 12-color antibody panels, which are shipped to the six Clinical Centers shortly before study visits. Sputum induction occurs at least two weeks before a bronchoscopy visit, at which time peripheral blood and bronchoalveolar lavage are collected. Immunostaining is performed at each clinical site on the day that the samples are collected. Samples are fixed and express shipped to the Immunophenotyping Core for data acquisition on a single modified LSR II flow cytometer. Results are analyzed using FACS Diva and FloJo software and cross-checked by Core scientists who are blinded to subject data. Thus far, a total of 152 sputum samples and 117 samples of blood and BAL have been returned to the Immunophenotyping Core. Initial quality checks indicate useable data from 126 sputum samples (83%), 106 blood samples (91%) and 91 BAL samples (78%). In all three sample types, we are able to identify and characterize the activation state or subset of multiple leukocyte cell populations (including CD4+ and CD8+ T cells, B cells, monocytes, macrophages, neutrophils and eosinophils), thereby demonstrating the validity of the antibody panel. Our study design, which relies on bi-directional communication between clinical centers and the Core according to a pre-specified protocol, appears to reduce several sources of variability often seen in flow cytometric studies involving multiple clinical sites. Because leukocytes contribute to lung pathology in COPD, these analyses will help achieve SPIROMICS aims of identifying subgroups of patients with specific COPD phenotypes. Future analyses will correlate cell-surface markers on a given cell type with smoking history, spirometry, airway measurements, and other parameters. This study was registered with ClinicalTrials.gov as NCT01969344 .
Keller, Krista A; Innis, Charles J; Tlusty, Michael F; Kennedy, Adam E; Bean, Sarah B; Cavin, Julie M; Merigo, Constance
2012-02-01
To assess selected clinicopathologic variables at hospital admission (day 1) for cold-stunned Kemp's ridley turtles (Lepidochelys kempii) that died during the first 3 days after admission (nonsurvivors) and turtles that survived (survivors) and to determine the percentage change of each variable from day 1 to day of death (nonsurvivors) or to day 2 or 3 of hospitalization (survivors). Retrospective case-control study. Animals-64 stranded, cold-stunned Kemp's ridley turtles hospitalized from October 2005 through December 2009. Blood gas, pH, Hct, and selected biochemical values in blood samples determined on day 1 and day of death (nonsurvivors; n = 32) or day 2 or 3 of hospitalization (survivors; 32) were obtained from medical records. For each variable, initial values and percentage changes (from initial values to values at the day of death or day 2 or 3 of hospitalization) were compared between survivors and nonsurvivors. Compared with blood analysis findings for survivors, nonsurvivors initially had significantly higher potassium concentration and Pco(2) and significantly lower Po(2), pH, and bicarbonate concentration than did survivors. For the first 2 or 3 days of hospitalization, percentage changes in potassium, lactate, and ionized calcium concentrations were significantly higher and percentage changes in pH and plasma glucose and bicarbonate concentrations were significantly lower in nonsurvivors. At hospital admission, cold-stunned Kemp's ridley turtles were affected by metabolic and respiratory derangements; severe derangements were associated with death. Evaluation of blood gas, pH, Hct, and selected clinicopathologic variables provided useful clinical and prognostic information during rehabilitation of cold-stunned Kemp's ridley turtles.
Automated processing of whole blood samples into microliter aliquots of plasma.
Burtis, C A; Johnson, W W; Walker, W A
1988-01-01
A rotor that accepts and automatically processes a bulk aliquot of a single blood sample into multiple aliquots of plasma has been designed and built. The rotor consists of a central processing unit, which includes a disk containing eight precision-bore capillaries. By varying the internal diameters of the capillaries, aliquot volumes ranging 1 to 10 mul can be prepared. In practice, an unmeasured volume of blood is placed in a centre well, and, as the rotor begins to spin, is moved radially into a central annular ring where it is distributed into a series of processing chambers. The rotor is then spun at 3000 rpm for 10 min. When the centrifugal field is removed by slowly decreasing the rotor speed, an aliquot of plasma is withdrawn by capillary action into each of the capillary tubes. The disk containing the eight measured aliquots of plasma is subsequently removed and placed in a modifed rotor for conventional centrifugal analysis. Initial evaluation of the new rotor indicates that it is capable of producing discrete, microliter volumes of plasma with a degree of accuracy and precision approaching that of mechanical pipettes.
NASA Technical Reports Server (NTRS)
Kirsch, K.
1981-01-01
A Spacelab experiment is described which proposes to obtain data on the degree of engorgement of the cephalad circulation during weightlessness by recording central venous pressure. Of practical importance is the question of how close the astronauts are to pulmonary edema and whether the pressure falls toward normal during the time of the mission. Another experiment to investigate deviations from normal fluid and mineral metabolism, possibly initiated by the central engorgement of the low pressure system, is discussed. Hormones responsible for the control of water and mineral balance (vasopressin, catecholamines, renin, aldosterone, corticosteroids, and prostaglandin E1) will be analyzed from blood samples.
Significant decreases in blood propofol concentrations during adrenalectomy for phaeochromocytoma.
Watanabe, Tatsunori; Hiraoka, Haruhiko; Araki, Takuya; Nagano, Daisuke; Aomori, Tohru; Nakamura, Tomonori; Yamamoto, Koujirou; Baba, Hiroshi
2017-10-01
The kinetics of propofol are influenced by cardiac output. The aim of this study was to examine changes in blood propofol concentrations during phaeochromocytoma surgery using target-controlled infusion (TCI) anaesthesia with propofol. This is a prospective observational study. Ten patients with phaeochromocytoma who underwent unilateral adrenalectomy were included. Cardiac output was measured using an arterial pressure-based cardiac output analysis method. The target blood propofol concentrations were adjusted to maintain an approximate bispectral index (BIS) value of 40 before initiating surgery. The settings remained constant during surgery. Blood samples for propofol concentrations were collected from the radial artery at seven time points: two before tumour manipulation (T1, 2), two during tumour manipulation (T3, 4), and three after tumour vein ligation (T4-7). BIS values, the arterial pressure cardiac index (APCI) and haemodynamic parameters were measured at the same time points as the blood samples. The prop-ratio was calculated by dividing blood propofol concentrations by target concentrations of TCI. APCI increased during tumour manipulation and after tumour vein ligation. The prop-ratio was reduced significantly by approximately 40% and showed a significant negative correlation with APCI. BIS values increased significantly and showed a significant negative correlation with the prop-ratio. The increased APCI during tumour manipulation and after tumour vein ligation was associated with markedly reduced blood propofol concentrations. These results reveal that significant decreases in the anaesthetic effect may be observed in patients undergoing phaeochromocytoma surgery even if TCI anaesthesia is used with propofol. © 2017 The British Pharmacological Society.
Blood pressure associated with sleep-disordered breathing in a population sample of children.
Bixler, Edward O; Vgontzas, Alexandros N; Lin, Hung-Mo; Liao, Duanping; Calhoun, Susan; Fedok, Fred; Vlasic, Vukmir; Graff, Gavin
2008-11-01
The current criteria for sleep-disordered breathing (SDB) in children are not based on a clinically relevant outcome. The purpose of this study was to assess the association of blood pressure with SDB in a random sample of the local elementary school children (kindergarten through grade 5) using a 2-phased strategy. During phase 1, a brief questionnaire was completed for all of the children (N=5740) with a response rate of 78.5%. During phase 2, 700 randomly selected children from phase 1 with a response rate of 70.0% were assessed with a full polysomnograph and a history/physical, including an ECG; ear, nose, and throat; and pulmonary evaluation. We observed a significantly elevated systolic blood pressure associated with the apnea hypopnea index (AHI): AHI >or=1 (2.9 mm Hg); AHI >or=3 (7.1 mm Hg); and AHI >or=5 (12.9 mm Hg). The SDB and blood pressure association remained significant after adjusting for age, sex, race, body mass index percentile or waist circumference, sleep efficiency, percentage of rapid eye movement sleep, and snoring. In addition, older age, body mass index percentile, waist circumference, and snoring were significantly associated with blood pressure, independent of SDB. Based on these findings, our study suggests that SDB is significantly associated with higher levels of systolic blood pressure in children aged 5 to 12 years even after adjusting for the various confounding factors. Clinically, the data support the threshold of AHI >or=5 for the initiation of treatment for SDB. Additional research is indicated to assess the efficacy of SDB treatment on reducing blood pressure.
In vitro adaptation of Plasmodium falciparum reveal variations in cultivability.
White, John; Mascarenhas, Anjali; Pereira, Ligia; Dash, Rashmi; Walke, Jayashri T; Gawas, Pooja; Sharma, Ambika; Manoharan, Suresh Kumar; Guler, Jennifer L; Maki, Jennifer N; Kumar, Ashwani; Mahanta, Jagadish; Valecha, Neena; Dubhashi, Nagesh; Vaz, Marina; Gomes, Edwin; Chery, Laura; Rathod, Pradipsinh K
2016-01-22
Culture-adapted Plasmodium falciparum parasites can offer deeper understanding of geographic variations in drug resistance, pathogenesis and immune evasion. To help ground population-based calculations and inferences from culture-adapted parasites, the complete range of parasites from a study area must be well represented in any collection. To this end, standardized adaptation methods and determinants of successful in vitro adaption were sought. Venous blood was collected from 33 P. falciparum-infected individuals at Goa Medical College and Hospital (Bambolim, Goa, India). Culture variables such as whole blood versus washed blood, heat-inactivated plasma versus Albumax, and different starting haematocrit levels were tested on fresh blood samples from patients. In vitro adaptation was considered successful when two four-fold or greater increases in parasitaemia were observed within, at most, 33 days of attempted culture. Subsequently, parasites from the same patients, which were originally cryopreserved following blood draw, were retested for adaptability for 45 days using identical host red blood cells (RBCs) and culture media. At a new endemic area research site, ~65% of tested patient samples, with varied patient history and clinical presentation, were successfully culture-adapted immediately after blood collection. Cultures set up at 1% haematocrit and 0.5% Albumax adapted most rapidly, but no single test condition was uniformly fatal to culture adaptation. Success was not limited by low patient parasitaemia nor by patient age. Some parasites emerged even after significant delays in sample processing and even after initiation of treatment with anti-malarials. When 'day 0' cryopreserved samples were retested in parallel many months later using identical host RBCs and media, speed to adaptation appeared to be an intrinsic property of the parasites collected from individual patients. Culture adaptation of P. falciparum in a field setting is formally shown to be robust. Parasites were found to have intrinsic variations in adaptability to culture conditions, with some lines requiring longer attempt periods for successful adaptation. Quantitative approaches described here can help describe phenotypic diversity of field parasite collections with precision. This is expected to improve population-based extrapolations of findings from field-derived fresh culture-adapted parasites to broader questions of public health importance.
NASA Astrophysics Data System (ADS)
Kravtsov, Alexander L.; Bobyleva, Elena V.; Grebenyukova, Tatyana P.; Kuznetsov, Oleg S.; Kulyash, Youri V.
2002-07-01
A quantitative flow microfluorometric method was used to study the intensity of human blood phagocyte degranulation in response to viable staphylococcus aureus or Yersinia pestis cells. Microorganisms were added directly to defibrinated whole blood. Uninfected and infected blood samples were incubated at 37 degrees C to 8 h. The results were recorded in dynamics after the staining of whole blood with acridine orange solution. Lymphocytes with a low azurophilic granule per cell content were discriminated from phagocytes by the measurement of single cell red cytoplasmic granule fluorescence. 30,000 cells in each sample were examined. S. aureus cells caused a dose-dependent decrease in the number of phagocytes having a high red cytoplasmic fluorescence intensity and a corresponding increase in the weakly fluorescence cell population. In the presence of an initial S. aureus-to-phagocyte ratio more than 1:1, degranulation was measured after 3 h of incubation and to 8 h the percentage of degranulated phagocytes was at least 100 percent Y. pestis cells grown for 48 h at 28 degrees C caused at same condition as the degranulation only about 50 percent of cells. Y.pestis EV cells preincubated in broth for 12 h at 37 degrees C did no stimulate the phahocyte degranulation. The results of these studies suggest that analysis of cell populations via flow microfluorimeter technology may be a powerful tool in analysis bacterial infection.
Sinnott, Margaret; Kinsley, Brendan T; Jackson, Abaigeal D; Walsh, Cathal; O'Grady, Tony; Nolan, John J; Gaffney, Peter; Boran, Gerard; Kelleher, Cecily; Carr, Bernadette
2015-01-01
Type 2 diabetes has a long pre clinical asymptomatic phase. Early detection may delay or arrest disease progression. The Diabetes Mellitus and Vascular health initiative (DMVhi) was initiated as a prospective longitudinal cohort study on the prevalence of undiagnosed Type 2 diabetes and prediabetes, diabetes risk and cardiovascular risk in a cohort of Irish adults aged 45-75 years. Members of the largest Irish private health insurance provider aged 45 to 75 years were invited to participate in the study. already diagnosed with diabetes or taking oral hypoglycaemic agents. Participants completed a detailed medical questionnaire, had weight, height, waist and hip circumference and blood pressure measured. Fasting blood samples were taken for fasting plasma glucose (FPG). Those with FPG in the impaired fasting glucose (IFG) range had a 75gm oral glucose tolerance test performed. 122,531 subjects were invited to participate. 29,144 (24%) completed the study. The prevalence of undiagnosed diabetes was 1.8%, of impaired fasting glucose (IFG) was 7.1% and of impaired glucose tolerance (IGT) was 2.9%. Dysglycaemia increased among those aged 45-54, 55-64 and 65-75 years in both males (10.6%, 18.5%, 21.7% respectively) and females (4.3%, 8.6%, 10.9% respectively). Undiagnosed T2D, IFG and IGT were all associated with gender, age, blood pressure, BMI, abdominal obesity, family history of diabetes and triglyceride levels. Using FPG as initial screening may underestimate the prevalence of T2D in the study population. This study is the largest screening study for diabetes and prediabetes in the Irish population. Follow up of this cohort will provide data on progression to diabetes and on cardiovascular outcomes.
Elevated blood harmane (1-methyl-9H-pyrido[3,4-b]indole) concentrations in essential tremor.
Louis, Elan D; Jiang, Wendy; Pellegrino, Kathryn M; Rios, Eileen; Factor-Litvak, Pam; Henchcliffe, Claire; Zheng, Wei
2008-03-01
Essential tremor (ET) is a widespread late-life neurological disease. Genetic and environmental factors likely play an etiological role. Harmane (1-methyl-9H-pyrido[3,4-b]indole) is a potent tremor-producing neurotoxin. In 2002, we demonstrated elevated blood harmane concentrations in an initial sample of 100 ET cases compared to 100 controls. Between 2002 and 2007, we assembled a new and larger sample of ET cases and controls. We now attempt to replicate our previous findings. Cases and controls were frequency-matched on age, gender, and race. Blood harmane concentrations were quantified by high-performance liquid chromatography. Subjects comprised 150 ET cases and 135 controls (mean age 65.3+/-15.5 vs. 65.5+/-14.2 years, p=0.94). Mean log blood harmane concentration was approximately 50% higher in cases than controls (0.50+/-0.54g(-10)/ml vs. 0.35+/-0.62g(-10)/ml, p=0.038). In a logistic regression analysis, log blood harmane concentration was associated with ET (OR(adjusted) 1.56, 95% CI 1.01-2.42, p=0.04), and odds of ET was 1.90 (95% CI 1.07-3.39, p=0.029) in the highest versus lowest log blood harmane tertile. Log blood harmane was highest in ET cases with familial ET (0.53+/-0.57g(-10)/ml), intermediate in cases with sporadic ET (0.43+/-0.45g(-10)/ml) and lowest in controls (0.35+/-0.62g(-10)/ml) (test for trend, p=0.026). Blood harmane appears to be elevated in ET. The higher concentrations in familial ET suggests that the mechanism may involve genetic factors.
ELEVATED BLOOD HARMANE (1-METHYL-9H-PYRIDO[3,4-B]INDOLE) CONCENTRATIONS IN ESSENTIAL TREMOR
Louis, Elan D.; Jiang, Wendy; Pellegrino, Kathryn M.; Rios, Eileen; Factor-Litvak, Pam; Henchcliffe, Claire; Zheng, Wei
2008-01-01
Essential tremor (ET) is a widespread late-life neurological disease. Genetic and environmental factors likely play an etiological role. Harmane (1-methyl-9H-pyrido[3,4-b]indole) is a potent tremor-producing neurotoxin. In 2002, we demonstrated elevated blood harmane concentrations in an initial sample of 100 ET cases compared to 100 controls. Between 2002 and 2007, we assembled a new and larger sample of ET cases and controls. We now attempt to replicate our previous findings. Cases and controls were frequency-matched on age, gender, and race. Blood harmane concentrations were quantified by high performance liquid chromatography. Subjects comprised 150 ET cases and 135 controls (mean age 65.3 ± 15.5 vs. 65.5 ± 14.2 years, p = 0.94). Mean log blood harmane concentration was ∼50% higher in cases than controls (0.50 ± 0.54 g -10/ml vs. 0.35 ± 0.62 g-10/ml, p = 0.038). In a logistic regression analysis, log blood harmane concentration was associated with ET (ORadjusted 1.56, 95% CI 1.01 - 2.42, p = 0.04), and odds of ET was 1.90 (95% CI 1.07 - 3.39, p = 0.029) in the highest vs. lowest log blood harmane tertile. Log blood harmane was highest in ET cases with familial ET (0.53 ± 0.57 g -10/ml), intermediate in cases with sporadic ET (0.43 ± 0.45 g -10/ml) and lowest in controls (0.35 ± 0.62 g-10/ml) (test for trend, p = 0.026). Blood harmane appears to be elevated in ET. The higher concentrations in familial ET suggests that the mechanism may involve genetic factors. PMID:18242711
Korfmacher, Walter; Luo, Yongyi; Ho, Stacy; Sun, Wei; Shen, Liduo; Wang, Jie; Wu, Zhongtao; Guo, Yang; Snow, Gregory; O'Shea, Thomas
2015-01-01
Serial sampling methods have been used for rat pharmacokinetic (PK) studies for over 20 years. Currently, it is still common to take 200-250 μL of blood at each timepoint when performing a PK study in rats and using serial sampling. While several techniques have been employed for collecting blood samples from rats, there is only limited published data to compare these methods. Recently, microsampling (≤ 50 μL) techniques have been reported as an alternative process for collecting blood samples from rats. In this report, five compounds were dosed orally into rats. For three proprietary compounds, jugular vein cannula (JVC) sampling was used to collect whole blood and plasma samples and capillary microsampling (CMS) was used to collect blood samples from the tail vein of the same animal. For the two other compounds, marketed drugs fluoxetine and glipizide, JVC sampling was used to collect both whole blood and blood CMS samples while tail-vein sampling from the same rats was also used to collect both whole blood and blood CMS samples. For the three proprietary compounds, the blood AUC as well as the blood concentration-time profile that were obtained from the tail vein were different from those obtained via JVC sampling. For fluoxetine, the blood total exposure (AUC) was not statistically different when comparing tail-vein sampling to JVC sampling, however the blood concentration-time profile that was obtained from the tail vein was different than the one obtained from JVC sampling. For glipizide, the blood AUC and concentration-time profile were not statistically different when comparing the tail-vein sampling to the JVC sampling. For both fluoxetine and glipizide, the blood concentration profiles obtained from CMS were equivalent to the blood concentration profiles obtained from the standard whole blood sampling, collected at the same sampling site. The data in this report provide strong evidence that blood CMS is a valuable small volume blood sampling approach for rats and that it provides results for test compound concentrations that are equivalent to those obtained from traditional whole blood sampling. The data also suggest that for some compounds, the concentration-time profile that is obtained for a test compound based on sampling from a rat tail vein may be different from that obtained from rat JVC sampling. In some cases, this shift in the concentration-time profile will result in different PK parameters for the test compound. Based on these observations, it is recommended that a consistent blood sampling method should be used for serial microsampling in discovery rat PK studies when testing multiple new chemical entities. If the rat tail vein sampling method is selected for PK screening, then conducting a bridging study on the lead compound is recommended to confirm that the rat PK obtained from JVC sampling is comparable to the tail-vein sampling. Copyright © 2015 Elsevier Inc. All rights reserved.
Occupational and environmental lead poisoning: case study of a battery recycling smelter in Taiwan.
Wang, J D; Soong, W T; Chao, K Y; Hwang, Y H; Jang, C S
1998-07-01
The rapid industrialization in Taiwan has caused both prosperity and environmental pollution. The purpose of this study is to demonstrate a case of both occupational and environmental lead poisoning. A patient of lead poisoning initiated a survey of the battery recycling factory, which revealed that 31 of 64 workers suffered from lead poisoning. Children who attended a nearby kindergarten showed a significant increase of blood lead up to 15-25 micrograms/dl and a mild but significant decrease of IQ (intelligent quotient, by Binet-Simon scale) if compared with children of a nonexposed but socioeconomically comparable kindergarten. Outdoor workers of the nearby forging factory also showed a significant increase of blood lead if compared with indoor workers or workers of another nonexposed forging factory 20 Km away. Air sampling showed an average of more than 10 micrograms/m3 in the kindergarten. Soil sampling and analysis also revealed 400 folds increase of lead content, which decreased if the sample was taken deep down to 15-30 cm or 350 meters away from the battery recycling smelter. Moreover, after children were moved away from the pollution source, follow-up examination performed 2.5 years later showed a significant decrease of blood lead and partial recovery of IQ among them.
Stock, W; Westbrook, C A; Peterson, B; Arthur, D C; Szatrowski, T P; Silver, R T; Sher, D A; Wu, D; Le Beau, M M; Schiffer, C A; Bloomfield, C D
1997-01-01
Disappearance of the Philadelphia chromosome during treatment for chronic myeloid leukemia (CML) has become an important therapeutic end point. To determine the additional value of molecular monitoring during treatment for CML, we performed a prospective, sequential analysis using quantitative Southern blot monitoring of BCR gene rearrangements of blood and marrow samples from Cancer and Leukemia Group B (CALGB) study 8761. Sixty-four previously untreated adults with chronic-phase CML who were enrolled onto CALGB 8761, a molecular-monitoring companion study to a treatment study for adults with chronic-phase CML (CALGB 9013). Treatment consisted of repetitive cycles of interferon alfa and low-dose subcutaneous cytarabine. Blood and marrow Southern blot quantitation of BCR gene rearrangements was compared with marrow cytogenetic analysis before the initiation of treatment and of specified points during therapy. Reverse-transcriptase polymerase chain reaction (RT-PCR) analysis was performed to detect residual disease in patients who achieved a complete response by Southern blot or cytogenetic analysis. Quantitative molecular monitoring by Southern blot analysis of blood samples was found to be equivalent to marrow monitoring at all time points. Twelve of 62 (19%) follow-up samples studied by Southern blot analysis had a complete loss of BCR gene rearrangement in matched marrow and blood specimens. Southern blot monitoring of blood samples was also found to be highly correlated to marrow cytogenetic evaluation at all points, although there were four discordant cases in which Southern blot analysis of blood showed no BCR gene rearrangement, yet demonstrated from 12% to 20% Philadelphia chromosome-positive metaphase cells in the marrow. RT-PCR analysis detected residual disease in five of six patients in whom no malignant cells were detected using Southern blot or cytogenetic analyses. Quantitative Southern blot analysis of blood samples may be substituted for bone marrow to monitor the response to therapy in CML and results in the need for fewer bone marrow examinations. To avoid overestimating the degree of response, marrow cytogenetic analysis should be performed when patients achieve a complete response by Southern blot monitoring. This approach provides a rational, cost-effective strategy to monitor the effect of treatment of individual patients, as well as to analyze large clinical trials in CML.
Kim, Sun-A; Lee, So-Yeong; Kimura, Junpei
2011-01-01
The purpose of this study was to evaluate the effect of alprazolam on the stress that Korean raccoon dogs (Nyctereutes procyonoides koreensis) may experience while caught in a live trap by measuring their serum cortisol response. The animals were placed in a live trap with or without being pretreated with oral doses of alprazolam. In both groups, pre-trap blood samples were initially collected without anesthesia before the animals were positioned in the live trap; then post-trap blood samples were collected after the animals had remained in the live trap for 2 h. Changes in cortisol levels were observed using a chemiluminescent immunoassay. The level of cortisol increased in the control group and decreased in the alprazolam-pretreatment group (p < 0.05). In this study, we demonstrated that alprazolam pretreatment reduced stress during live trap capture. PMID:21368571
Kim, Sun-A; Lee, So-Yeong; Kimura, Junpei; Shin, Nam-Shik
2011-03-01
The purpose of this study was to evaluate the effect of alprazolam on the stress that Korean raccoon dogs (Nyctereutes procyonoides koreensis) may experience while caught in a live trap by measuring their serum cortisol response. The animals were placed in a live trap with or without being pretreated with oral doses of alprazolam. In both groups, pre-trap blood samples were initially collected without anesthesia before the animals were positioned in the live trap; then post-trap blood samples were collected after the animals had remained in the live trap for 2 h. Changes in cortisol levels were observed using a chemiluminescent immunoassay. The level of cortisol increased in the control group and decreased in the alprazolam-pretreatment group (p < 0.05). In this study, we demonstrated that alprazolam pretreatment reduced stress during live trap capture.
Spindelboeck, Walter; Gemes, Geza; Strasser, Christa; Toescher, Kathrin; Kores, Barbara; Metnitz, Philipp; Haas, Josef; Prause, Gerhard
2016-09-01
An arterial blood gas analysis (ABG) yields important diagnostic information in the management of cardiac arrest. This study evaluated ABG samples obtained during out-of-hospital cardiopulmonary resuscitation (OHCPR) in the setting of a prospective multicenter trial. We aimed to clarify prospectively the ABG characteristics during OHCPR, potential prognostic parameters and the ABG dynamics after return of spontaneous circulation (ROSC). ABG samples were collected and instantly processed either under ongoing OHCPR performed according to current advanced life support guidelines or immediately after ROSC and data ware entered into a case report form along with standard CPR parameters. During a 22-month observation period, 115 patients had an ABG analysis during OHCPR. In samples obtained under ongoing CPR, an acidosis was present in 98% of all cases, but was mostly of mixed hypercapnic and metabolic origin. Hypocapnia was present in only 6% of cases. There was a trend towards higher paO2 values in patients who reached sustained ROSC, and a multivariate regression analysis revealed age, initial rhythm, time from collapse to CPR initiation and the arterio-alveolar CO2 difference (AaDCO2) to be associated with sustained ROSC. ABG samples drawn immediately after ROSC demonstrated higher paO2 and unaltered pH and base excess levels compared with samples collected during ongoing CPR. Our findings suggest that adequate ventilation and oxygenation deserve more research and clinical attention in the management of cardiac arrest and that oxygen uptake improves within minutes after ROSC. Hyperventilation resulting in arterial hypocapnia is not a major problem during OHCPR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Grinberg, Austin M; O'Hara, Karey L; Sbarra, David A
2018-03-01
This study explores cardiovascular reactivity during an acute-stress task in a sample of recently separated adults. In a cross-sectional design, we examined the association between adults' subjective separation-related distress and changes in heart rate and blood pressure across the acute-stress laboratory paradigm in a sample of 133 (n = 49 men) recently separated adults. Heart rate (HR) and Blood pressure (BP) were recorded across a resting baseline period, a math stressor task, and a recovery period. Multilevel analyses revealed that adults who reported greater separation-related distress exhibited higher initial BP and a slower linear increase in BP across the study period. In addition, adults reporting greater separation-related distress evidenced significantly slower declines in diastolic blood pressure (DBP) following the acute-stress task. HR reactivity was not moderated by separation-related distress. In recently separated adults, preliminary evidence suggests that the context of the stressors may reveal differential patterns of problematic reactivity (exaggerated or blunted responding). Greater emotional intrusion and hyperactivity symptoms may index increased risk for blunted cardiovascular reactivity to general stressors. This pattern of reactivity is consistent with models of allostatic load that emphasise the deleterious effect of hyporesponsivity to environmental demands.
Zhang, Xiaolian; Yang, Dongmei; Lu, Yu; Lao, Xianjun; Qin, Xue; Li, Shan
2016-01-01
Detecting blood levels of hepatitis B virus (HBV) DNA must be accurate and credible. Shipment and storage conditions of clinical samples affect the quality of nucleic acids and can interfere with HBV DNA analysis. The aim of our study was to compare HBV DNA stability in plasma specimens at 4 degrees C for different storage periods. Blood samples from 30 hepatitis B surface antigen (HBsAg) positive patients were collected in tubes containing EDTA-K2. Each sample was divided into eight aliquots, one of which was measured immediately for the initial viral load. The remaining aliquots were then stored at 4 degrees C and assessed after 1, 2, 3, 7, 14, 21, and 30 days of storage. Quantification of HBV DNA was performed by real-time polymerase chain reaction (RT-PCR), and the difference in HBV DNA concentrations between two different time points was analysed with a paired-samples t-test. HBV DNA was measured in a range of 2.00 - 8.00 IU/mL, with low within-run and between-run coefficients of variation (< 10%). Storing plasma for one month at 4 degrees C revealed no significant decrease in HBV DNA level (p = 0.231), and no trend was evident to indicate continued reduction over a 3-week storage period. Based on the results of this study, storing plasma for up to one month at 4 degrees C does not affect the stability of HBV DNA, regardless of the initial viral load.
Karakoc, Ayse Esra; Berkem, Rukiye; Irmak, Hasan; Demiroz, Ali Pekcan; Yenicesu, Idil; Ertugrul, Nigar; Arslan, Önder; Kemahli, Sabri; Yilmaz, Sevinc; Ozcebe, Osman; Kara, Abdurrahman; Ozet, Gulsum; Acikgoz, Ziya Cibali; Acikgoz, Tulin
2017-10-01
In this study we aimed to propose an algorithm for initial anti HCV EIA reactive blood donations in Turkey where nucleic acid amplification tests are not yet obligatory for donor screening. A total of 416 anti HCV screening test reactive donor samples collected from 13 blood centers from three cities in Turkey were tested in duplicate by Ortho HCV Ab Version 3.0 and Radim HCV Ab. All the repeat reactive samples were tested by INNO-LIA HCV Ab 3.0 or Chiron RIBA HCV 3.0 and Abbott Real Time HCV. Intra-assay correlations were calculated with Pearson r test. ROC analysis was used to study the relationship between EIA tests and the confirmatory tests. The number of repeat reactive results with Ortho EIA were 221 (53.1%) whereas that of microEIA, 62 (14.9%). Confirmed positivity rate was 14.6% (33/226) by RIBA and 10.6% (24/226) by NAT. Reactive PCR results were predicted with 100% sensitivity and 95% specificity with S/CO levels of 8.1 with Ortho EIA and 3.4 with microEIA. Repeat reactivity rates declined with a second HCV antibody assay. Samples repeat reactive with one HCV antibody test and negative with the other were all NAT negative. All the NAT reactive samples were RIBA positive. None of the RIBA indeterminate or negative samples were NAT reactive. Considering the threshold values for EIA kits determined by ROC analysis NAT was decided to be performed for the samples above the threshold value and a validated supplemental HCV antibody test for the samples below. Copyright © 2017 Elsevier Ltd. All rights reserved.
Stark, Peter C [Los Alamos, NM; Zurek, Eduardo [Barranquilla, CO; Wheat, Jeffrey V [Fort Walton Beach, FL; Dunbar, John M [Santa Fe, NM; Olivares, Jose A [Los Alamos, NM; Garcia-Rubio, Luis H [Temple Terrace, FL; Ward, Michael D [Los Alamos, NM
2011-07-26
There is provided a method and device for remote sampling, preparation and optical interrogation of a sample using light scattering and light absorption methods. The portable device is a filtration-based device that removes interfering background particle material from the sample matrix by segregating or filtering the chosen analyte from the sample solution or matrix while allowing the interfering background particles to be pumped out of the device. The segregated analyte is then suspended in a diluent for analysis. The device is capable of calculating an initial concentration of the analyte, as well as diluting the analyte such that reliable optical measurements can be made. Suitable analytes include cells, microorganisms, bioparticles, pathogens and diseases. Sample matrixes include biological fluids such as blood and urine, as well as environmental samples including waste water.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lassen, N.A.; Henriksen, L.; Holm, S.
1983-01-01
Tomographic maps of local cerebral blood flow (CBF) were obtained with xenon-133 and with isopropyl-amphetamine-iodine-123 (IMP) in 11 subjects: one normal, two tumor cases, and eight cerebrovascular cases. A highly sensitive four-face, rapidly rotating, single-photon emission tomograph was used. The Xe-133 flow maps are essentially based on the average Xe-133 concentration over the initial 2 min during and after an inhalation of the inert gas lasting 1 min. These maps agreed very well with the early IMP maps obtained over the initial 10 min following an i.v. bolus injection. The subsequent IMP tomograms showed a slight decrease in contrast amountingmore » to appr. five percentage points in the CBF ratio between diseased and contralateral areas. It is concluded that Xe-133 is more practical: low cost, available on a 7-day basis, easily repeatable, quantifiable without the need for arterial sampling, and with low radiation exposure to patient and personnel. On the other hand, IMP gives an image of slightly higher resolution. It also introduces a new class of iodinated brain-seeking compounds allowing, perhaps, imaging of other functions more important than mere blood flow.« less
Enders, Martin; Hunjet, Andrea; Gleich, Michael; Imdahl, Roland; Mühlbacher, Annelies; Schennach, Harald; Chaiwong, Kriangsak; Sakuldamrongpanich, Tasanee; Turhan, Ajda; Sertöz, Rüchan; Wolf, Eva; Mayer, Wolfgang; Tao, Chuanmin; Wang, Lan Lan; Semprini, Simona
2014-01-01
Syphilis is a health problem of increasing incidence in recent years that may have severe complications if not diagnosed and treated at an early stage. There are many diagnostic tests available for syphilis, but there is no gold standard, and diagnosis therefore usually relies upon a combination of tests. In this multicenter study, we evaluated the treponemal Elecsys syphilis assay for use in the diagnosis of syphilis in routine samples, i.e., when syphilis is suspected or during antenatal or blood donation screening. The sensitivity and specificity of the Elecsys syphilis assay were compared head to head with those of other treponemal assays used in routine clinical practice and were assessed in potentially cross-reactive samples from patients with Epstein-Barr virus, HIV, and Lyme disease. In a total of 8,063 syphilis-negative samples collected from routine diagnostic requests and blood donations, the Elecsys syphilis assay had a specificity of 99.88%. In 928 samples previously identified as syphilis positive, the sensitivity was 99.57 to 100% (the result is presented as a range depending on whether four initially indeterminate samples are included in the assessment). The specificity of the Elecsys syphilis assay in patients with other infections was 100%; no false-positive samples were identified. PMID:25355799
Identification of Differentially Expressed Genes in Blood Cells of Narcolepsy Patients
Tanaka, Susumu; Honda, Yutaka; Honda, Makoto
2007-01-01
Study Objective: A close association between the human leukocyte antigen (HLA)-DRB1*1501/DQB1*0602 and abnormalities in some inflammatory cytokines have been demonstrated in narcolepsy. Specific alterations in the immune system have been suggested to occur in this disorder. We attempted to identify alterations in gene expression underlying the abnormalities in the blood cells of narcoleptic patients. Designs: Total RNA from 12 narcolepsy-cataplexy patients and from 12 age- and sex-matched healthy controls were pooled. The pooled samples were initially screened for candidate genes for narcolepsy by differential display analysis using annealing control primers (ACP). The second screening of the samples was carried out by semiquantitative PCR using gene-specific primers. Finally, the expression levels of the candidate genes were further confirmed by quantitative real-time PCR using a new set of samples (20 narcolepsy-cataplexy patients and 20 healthy controls). Results: The second screening revealed differential expression of 4 candidate genes. Among them, MX2 was confirmed as a significantly down-regulated gene in the white blood cells of narcoleptic patients by quantitative real-time PCR. Conclusion: We found the MX2 gene to be significantly less expressed in comparison with normal subjects in the white blood cells of narcoleptic patients. This gene is relevant to the immune system. Although differential display analysis using ACP technology has a limitation in that it does not help in determining the functional mechanism underlying sleep/wakefulness dysregulation, it is useful for identifying novel genetic factors related to narcolepsy, such as HLA molecules. Further studies are required to explore the functional relationship between the MX2 gene and narcolepsy pathophysiology. Citation: Tanaka S; Honda Y; Honda M. Identification of differentially expressed genes in blood cells of narcolepsy patients. SLEEP 2007;30(8):974-979. PMID:17702266
NASA Astrophysics Data System (ADS)
Zhang, Linna; Zhang, Shengzhao; Sun, Meixiu; Li, Hongxiao; Li, Yingxin; Fu, Zhigang; Guan, Yang; Li, Gang; Lin, Ling
2017-03-01
Discrimination of human and nonhuman blood is crucial for import-export ports and inspection and quarantine departments. Current methods are usually destructive, complicated and time-consuming. We had previously demonstrated that visible diffuse reflectance spectroscopy combining PLS-DA method can successfully realize human blood discrimination. In that research, the spectra were measured with the fiber probe under the surface of blood samples. However, open sampling may pollute the blood samples. Virulence factors in blood samples can also endanger inspectors. In this paper, we explored the classification effect with the blood samples measured in the original containers-vacuum blood vessel. Furthermore, we studied the impact of different conditions of blood samples, such as coagulation and hemolysis, on the prediction ability of the discrimination model. The calibration model built with blood samples in different conditions displayed a satisfactory prediction result. This research demonstrated that visible and near-infrared diffuse reflectance spectroscopy method was potential for noncontact discrimination of human blood.
Bryant, Gillian L; Fleming, Patricia A; Twomey, Leanne; Warren, Kristin A
2012-04-01
Despite increased worldwide popularity of keeping reptiles as pets, we know little about hematologic and biochemical parameters of most reptile species, or how these measures may be influenced by intrinsic and extrinsic factors. Blood samples from 43 wild-caught pythons (Morelia spilota imbricata) were collected at various stages of a 3-yr ecological study in Western Australia. Reference intervals are reported for 35 individuals sampled at the commencement of the study. As pythons were radiotracked for varying lengths of time (radiotransmitters were surgically implanted), repeated sampling was undertaken from some individuals. However, because of our ad hoc sampling design we cannot be definitive about temporal factors that were most important or that exclusively influenced blood parameters. There was no significant effect of sex or the presence of a hemogregarine parasite on blood parameters. Erythrocyte measures were highest for pythons captured in the jarrah forest and at the stage of radiotransmitter implantation, which was also linked with shorter time in captivity. Basophil count, the only leukocyte influenced by the factors tested, was highest when the python was anesthetized, as was globulin concentration. Albumin and the albumin:globulin ratio were more concentrated in summer (as was phosphorous) and at the initial stage of radiotransmitter placement (as was calcium). No intrinsic or extrinsic factors influenced creatinine kinase, aspartate aminotransferase, uric acid, or total protein. This study demonstrates that factors including season, location, surgical radiotransmitter placement, and anesthetic state can influence blood parameters of M. s. imbricata. For accurate diagnosis, veterinarians should be aware that the current reference intervals used to identify the health status of individuals for this species are outdated and the interpretation and an understanding of the influence of intrinsic and extrinsic factors are limited.
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
Method of assessing a lipid-related health risk based on ion mobility analysis of lipoproteins
Benner, W. Henry; Krauss, Ronald M.; Blanche, Patricia J.
2010-12-14
A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.
Strandberg, G; Larsson, A; Lipcsey, M; Berglund, L; Eriksson, M
2014-03-01
Intraosseous (IO) access is used in emergency situations to allow rapid initiation of treatment. IO access is also sometimes used for blood sampling, although data on accuracy of such sampling in critical illness are limited. There is also a potential risk that bone marrow fragments in IO samples may damage laboratory equipment. It is ethically questionable to perform a simultaneous comparison between IO and arterial/venous sampling in critically ill humans. We have, thus, studied the analytical performance of IO sampling in a porcine septic shock model using a cartridge-based analyser. Eight pigs with endotoxin-induced septic shock were sampled hourly for 6 h, and analysed for blood gases, acid base status, haemoglobin, glucose and lactate using point of care instruments. Samples were taken from three IO cannulae (tibia bilaterally, one with infusion, and humerus), one arterial and one venous. An interaction test was used to assess changes in agreement between methods over time. Bland–Altman plots were constructed to study bias between methods. There were, to a varying extent, differences between IO and arterial/venous levels for all studied variables, but agreement did not change significantly during the experiment. A general finding was a large dispersion of differences between methods. IO sample values should be treated with caution in this setting but may add useful information to the clinical picture. The tibia or humerus may be used for sampling. IO infusion decreases agreement, thus sampling during infusion should be avoided.
Cheung, Chi Yuen; van der Heijden, Jaques; Hoogtanders, Karin; Christiaans, Maarten; Liu, Yan Lun; Chan, Yiu Han; Choi, Koon Shing; van de Plas, Afke; Shek, Chi Chung; Chau, Ka Foon; Li, Chun Sang; van Hooff, Johannes; Stolk, Leo
2008-02-01
Dried blood spot (DBS) sampling and high-performance liquid chromatography tandem-mass spectrometry have been developed in monitoring tacrolimus levels. Our center favors the use of limited sampling strategy and abbreviated formula to estimate the area under concentration-time curve (AUC(0-12)). However, it is inconvenient for patients because they have to wait in the center for blood sampling. We investigated the application of DBS method in tacrolimus level monitoring using limited sampling strategy and abbreviated AUC estimation approach. Duplicate venous samples were obtained at each time point (C(0), C(2), and C(4)). To determine the stability of blood samples, one venous sample was sent to our laboratory immediately. The other duplicate venous samples, together with simultaneous fingerprick blood samples, were sent to the University of Maastricht in the Netherlands. Thirty six patients were recruited and 108 sets of blood samples were collected. There was a highly significant relationship between AUC(0-12), estimated from venous blood samples, and fingerprick blood samples (r(2) = 0.96, P < 0.0001). Moreover, there was an excellent correlation between whole blood venous tacrolimus levels in the two centers (r(2) = 0.97; P < 0.0001). The blood samples were stable after long-distance transport. DBS sampling can be used in centers using limited sampling and abbreviated AUC(0-12) strategy as drug monitoring.
Goto, Shinya; Tamura, Noriko; Ishida, Hideyuki
2004-07-21
We examined the lytic effects of anti-glycoprotein (GP) IIb/IIIa agents on platelet thrombi formed on the collagen surface under blood flow conditions. Anti-GP IIb/IIIa agents may influence platelet thrombi already formed. Blood samples were anticoagulated either by the specific antithrombin Argatroban (100 microM) or by unfractionated heparin (0.1 U/ml). After platelet thrombi were formed on a collagen surface following 6-min perfusion of whole blood obtained from eight adult donors containing fluorescinated platelets at a wall shear rate of 1,500 s(-1), additional blood samples from the same donors either containing or not containing anti-GP IIb/IIIa agents (abciximab, eptifibatide, or tirofiban) were perfused on these thrombi. The three-dimensional structures of the platelet thrombi were continuously observed by laser confocal microscopy equipped with a piezo-electric motor control unit and recorded. The platelet thrombi started to dissolve after perfusion of blood containing the anti-GP IIb/IIIa agents, whereas their growth resumed after subsequent perfusion of control blood. Only a single layer of platelets having heights of 3 +/- 1 microm, 3 +/- 2 microm, and 3 +/- 1 microm, respectively, could be seen after 6-min perfusion of blood containing abciximab, eptifibatide, and tirofiban, whereas the initial height of the platelet thrombi of 8 +/- 2 microm increased to 11 +/- 4 microm after subsequent perfusion of control blood (n = 8). The volume of the platelet thrombi, which was 3,352 +/- 1,045 microm(3) before starting the second perfusion, was reduced to 778 +/- 102 microm(3), 812 +/- 122 microm(3), and 856 +/- 144 microm(3) after 6-min perfusion of blood containing abciximab, eptifibatide, and tirofiban, respectively. We have shown in this study that anti-GP IIb/IIIa agents possess the ability to dissolve platelet thrombi.
Leidinger, Petra; Backes, Christina; Rheinheimer, Stefanie; Keller, Andreas; Meese, Eckart
2015-01-01
Circulating microRNAs (miRNAs) from blood are increasingly recognized as biomarker candidates for human diseases. Clinical routine settings frequently include blood sampling in tubes with EDTA as anticoagulant without considering the influence of phlebotomy on the overall miRNA expression pattern. We collected blood samples from six healthy individuals each in an EDTA blood collection tube. Subsequently, the blood was transferred into PAXgeneTM tubes at three different time points, i.e. directly (0 min), 10 min, and 2 h after phlebotomy. As control blood was also directly collected in PAXgeneTM blood RNA tubes that contain a reagent to directly lyse blood cells and stabilize their content. For all six blood donors at the four conditions (24 samples) we analyzed the abundance of 1,205 miRNAs by human Agilent miRNA V16 microarrays. While we found generally a homogenous pattern of the miRNA abundance in all 24 samples, the duration of the EDTA treatment appears to influence the miRNA abundance of specific miRNAs. The most significant changes are observed after longer EDTA exposition. Overall, the impact of the different blood sample conditions on the miRNA pattern was substantially lower than intra-individual variations. While samples belonging to one of the six individuals mostly cluster together, there was no comparable clustering for any of the four tested blood sampling conditions. The most affected miRNA was miR-769-3p that was not detected in any of the six PAXgene blood samples, but in all EDTA 2h samples. Accordingly, hsa-miR-769-3p was also the only miRNA that showed a significantly different abundance between the 4 blood sample conditions by an ANOVA analysis (Benjamini-Hochberg adjusted p-value of 0.003). Validation by qRT-PCR confirmed this finding. The pattern of blood-borne miRNA abundance is rather homogenous between the four tested blood sample conditions of six blood donors. There was a clustering between the miRNA profiles that belong to a specific blood donor, but not between any of the four tested blood sampling conditions. The results show a limited overall impact of the blood sampling conditions on the miRNA pattern. Notwithstanding, the abundance of single miRNAs can be significantly altered by different blood sampling conditions.
Variable Saline Concentrations for Initial Resuscitation Following Polytrauma
2017-02-22
sagittal suture between the coronal and lambdoid suture lines. Head injury was induced by dropping a cylindrical rod weighing 400 grams from 1.5 cm...injury. Brain samples were perfusion fixed and evaluated for extent of injury with hematoxylin and eosin staining . 3.5 Capillary Leak and Blood...Distribution is unlimited. Cleared, 88PA, Case # 2017-2329, 15 May 2017. 4.8 Histology Hematoxylin and eosin staining demonstrated no differences
Interferon-gamma response to the treatment of active pulmonary and extra-pulmonary tuberculosis.
Liang, L; Shi, R; Liu, X; Yuan, X; Zheng, S; Zhang, G; Wang, W; Wang, J; England, K; Via, L E; Cai, Y; Goldfeder, L C; Dodd, L E; Barry, C E; Chen, R Y
2017-10-01
Interferon-gamma (IFN-γ) release assays (IGRAs) are used to diagnose tuberculosis (TB) but not to measure treatment response. To measure IFN-γ response to active anti-tuberculosis treatment. Patients from the Henan Provincial Chest Hospital, Henan, China, with TB symptoms and/or signs were enrolled into this prospective, observational cohort study and followed for 6 months of treatment, with blood and sputum samples collected at 0, 2, 4, 6, 8, 16 and 24 weeks. The QuantiFERON® TB-Gold assay was run on collected blood samples. Participants received a follow-up telephone call at 24 months to determine relapse status. Of the 152 TB patients enrolled, 135 were eligible for this analysis: 118 pulmonary (PTB) and 17 extra-pulmonary TB (EPTB) patients. IFN-γ levels declined significantly over time among all patients (P = 0.002), with this decline driven by PTB patients (P = 0.001), largely during the initial 8 weeks of treatment (P = 0.019). IFN-γ levels did not change among EPTB patients over time or against baseline culture or drug resistance status. After 6 months of effective anti-tuberculosis treatment, IFN-γ levels decreased significantly in PTB patients, largely over the initial 8 weeks of treatment. IFN-γ concentrations may offer some value for monitoring anti-tuberculosis treatment response among PTB patients.
Thromboelastography in wild Florida manatees (Trichechus manatus latirostris).
Barratclough, Ashley; Floyd, Ruth Francis; Reep, Roger L; Ball, Ray L; Conner, Bobbi J
2018-03-09
Thromboelastography (TEG) provides a comprehensive evaluation of blood clot formation. This test can be used to identify abnormalities in coagulation by assessing multiple aspects of the clotting cascade, including the speed of clot initiation and formation, clot strength, and ultimately fibrinolysis. Thromboembolic disease has been hypothesized to play a role in the pathophysiology of cold stress syndrome (CSS), an important cause of mortality in the threatened Florida manatee (Trichechus manatus latirostris). The objective of this study was to establish thromboelastography RIs using the TEG 5000 with citrated whole blood samples and kaolin activation in wild, healthy manatees. In December 2014 and January 2015, 29 wild manatees (17 male and 12 female) were blood sampled as part of the annual wild manatee health assessments organized by United States Geological Survey (USGS). TEG was performed using citrated kaolin-activated samples. The samples were obtained from manatees caught in Crystal River, Citrus County, and used to identify the mean ± SD of normal TEG parameters: R = reaction time 2.1 minutes (0.8), K = clot formation time 0.8 min (0), α angle = 83.1° (2), MA = maximum amplitude 75 mm (7.6), and LY30 = clot lysis 0.41% (0.68). No significant differences were found between manatee size, sex, or time between sampling and running the test. Manatee TEG parameters demonstrate a relatively hypercoagulable condition when compared to other mammals. This information will facilitate detection of changes in hemostasis during injury and disease and provide a valuable reference range. © 2018 American Society for Veterinary Clinical Pathology.
Flores, Ana I; McKenna, David H; Montalbán, M Angeles; De la Cruz, Javier; Wagner, John E; Bornstein, Rafael
2009-04-01
The CD34+ cell content is a predictive factor for engraftment and survival after umbilical cord blood (UCB) transplantation. The high variability in the CD34 assay results in different recommended cell doses for infusion across transplant centers and also limits the clinical utility of the CD34+ cell counts provided by cord blood banks (CBBs). This bi-institutional study was intended to understand the sources of this variability. The level of CD34 agreement between the University of Minnesota (UM) and the Madrid CBB (MCBB) was evaluated on 50 UCB units before and after cryopreservation. Two cryopreserved vials per unit were thawed and processed at both laboratories. Dual-platform ISHAGE-based flow cytometry was used for CD34 enumeration. Postthaw nucleated cell recoveries were similar. However, whereas CD34+ cell enumeration before freezing was 0.35 +/- 0.22 percent, the results after thawing were 0.98 +/- 0.65 and 0.57 +/- 0.39 percent at UM and MCBB, respectively. Bland-Altman plots analysis ruled out the interchangeability of MCBB and UM CD34 values. Differences in the initial cell acquisition settings accounted for most of the CD34 discrepancy, which was no longer present after normalization of the forward scatter threshold for cell acquisition. The standardization of CD34+ cell enumeration by flow cytometry is strongly reliant on a consistent initial cell acquisition procedure. The interlaboratory variation can be minimized by using frozen cell aliquots as reference samples. Both requisites should be considered for CD34 testing and UCB unit selection by regulatory institutions involved with cord blood banking and transplantation.
Lieshout-Krikke, R W; van 't Ende, E A; Slot, E; Karomi, S; Kivit, R M H; Zaaijer, H L
2012-04-01
Blood can be infectious if it is donated shortly before infection with hepatitis B virus (HBV), hepatitis C virus (HCV) or human immunodeficiency virus (HIV) becomes detectable. Lookback exercises may detect infection in recipients of pre-seroconversion donations. This study provides an analysis of the Dutch lookback exercises in the years 2000 through 2006. All lookback procedures, triggered by 50 repeat donors seroconverting for HBV (n=32), HCV (n=3), HIV (n=14) and HBV + HIV (n=1), were analysed. Recipients and archived samples of the 96 implicated donations were tested. For 76 donations, a stored sample was available for HBV, HCV, or HIV PCR testing, revealing two HBV-DNA-positive pre-seroconversion donations. Ninety-three lookback procedures were initiated, to which 91 of 93 hospitals responded. In 87 of 91 cases, the implicated blood product had been administered. In 39 of 87 cases, the recipient was tested, revealing one HIV and two HBV infections. The HIV infection was considered pre-existent. The two HBV-positive patients received components from the donation of which the repository sample tested positive for HBV-DNA. Components of the second HBV-positive pre-seroconversion donation had not been administered. Among 39 recipients of pre-seroconversion donations, 2 (5%) were found HBV infected by transfusion. The labour-intensive lookback procedures did not reveal any conclusive transmissions additional to the infections detected by PCR testing of repository pre-seroconversion samples. © 2011 The Author(s). Vox Sanguinis © 2011 International Society of Blood Transfusion.
Fatal Babesia canis canis infection in a splenectomized Estonian dog.
Tiškina, Valentina; Capligina, Valentina; Must, Külli; Berzina, Inese; Ranka, Renate; Jokelainen, Pikka
2016-01-25
A previously splenectomized dog from Estonia was presented with a sudden lack of appetite and discoloration of the urine. Despite supportive therapy, its condition deteriorated dramatically during 1 day. Severe thrombocytopenia and high numbers of protozoan hemoparasites were evident in blood smears, and the hematocrit dropped from 46 to 33 %. The dog was euthanized before specific antibabesial treatment was initiated. Blood samples from the dog and from two other dogs in the same household tested positive for Babesia using molecular methods, and the sequences of partial 18S rRNA gene confirmed the causative species as Babesia canis canis. The risk of severe, rapidly progressing babesiosis in splenectomized dogs merits awareness.
Environmental health collaboration: United States and Russia.
Rubin, C H; Jones, R L; Revich, B; Avaliani, S L; Gurvich, E
2003-08-01
Developed nations share similar challenges to human health from commercial and agricultural chemicals that are released into the environment. Although Russia and the United States are historically distinct and unique, both countries are geographically large and economically dependent on emission-producing surface transportation. This paper describes U.S.-Russian collaborative activities that grew from a 1995 conference in Moscow that brought together environmental health investigators from both countries to discuss common concerns about the human health impact of environmental pollutants. Lead, pesticides, volatile organic compounds, and mercury were identified as contaminants of greatest concern. Collaborative studies were initiated that included collecting blood and hair samples and splitting samples for analyses in both countries, and introducing and sharing new portable blood and environmental sample analyses instruments. The findings demonstrated that hair analysis was not a good predictor of BLL and that Russian children in the first city sampled had a mean BLL of 7.7 microg/dl. Although higher than the U.S. mean, this level was below the 10.0 microg/dl CDC level of concern. This manuscript summarizes additional study results and describes their impacts on Russian policy. On-going collaborative environmental investigations are described.
Nwachukwu, Ifeanyi D.; Girgih, Abraham T.; Malomo, Sunday A.; Onuh, John O.; Aluko, Rotimi E.
2014-01-01
Thermoase-digested flaxseed protein hydrolysate (FPH) samples and ultrafiltration membrane-separated peptide fractions were initially evaluated for in vitro inhibition of angiotensin I-converting enzyme (ACE) and renin activities. The two most active FPH samples and their corresponding peptide fractions were subsequently tested for in vivo antihypertensive activity in spontaneously hypertensive rats (SHR). The FPH produced with 3% thermoase digestion showed the highest ACE- and renin-inhibitory activities. Whereas membrane ultrafiltration resulted in significant (p < 0.05) increases in ACE inhibition by the <1 and 1–3 kDa peptides, only a marginal improvement in renin-inhibitory activity was observed for virtually all the samples after membrane ultrafiltration. The FPH samples and membrane fractions were also effective in lowering systolic blood pressure (SBP) in SHR with the largest effect occurring after oral administration (200 mg/kg body weight) of the 1–3 kDa peptide fraction of the 2.5% FPH and the 3–5 kDa fraction of the 3% FPH. Such potent SBP-lowering capacity indicates the potential of flaxseed protein-derived bioactive peptides as ingredients for the formulation of antihypertensive functional foods and nutraceuticals. PMID:25302619
Kovacs, Eva M R; Westerterp-Plantenga, Margriet S; Saris, Wim H M; Melanson, Kathleen J; Goossens, Ine; Geurten, Peter; Brouns, Fred
2002-01-01
The aim of the present study was to investigate associations between spontaneous meal initiations and blood glucose dynamics in overweight male subjects in negative energy balance. In a randomized crossover design, fifteen overweight male subjects (BMI 28.6 (SD 1.8 kg/m2) participated in three treatments, each of which consisted of 2 weeks consuming a low-energy diet followed by a test of voluntary food ingestion in the absence of time-related cues. The low-energy diet consisted of three daily meals (947 kJ) which were either semi-solid with or without 2.5 g guar gum, or solid, and a dinner of subject's own choice. During the time-blinded test, on the first, second, and third meal initiation subjects ingested a low-energy meal corresponding to that used during the preceding weeks. Changes in blood glucose were monitored on-line. Associations between spontaneous meal initiations and blood glucose dynamics were determined using the chi2 test. No difference was found between treatments in the occurrence of postabsorptive and postprandial declines in blood glucose or in associations between meal initiations and blood glucose dynamics. Postprandial dynamic blood glucose declines were associated with meal initiation (chi2 26 8, P<0.00 1), but postabsorptive and postprandial transient declines were not. In overweight subjects, the usual association between transient declines and spontaneous meal initiation was completely absent in negative energy balance.
Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip
Yeh, Erh-Chia; Fu, Chi-Cheng; Hu, Lucy; Thakur, Rohan; Feng, Jeffrey; Lee, Luke P.
2017-01-01
Portable, low-cost, and quantitative nucleic acid detection is desirable for point-of-care diagnostics; however, current polymerase chain reaction testing often requires time-consuming multiple steps and costly equipment. We report an integrated microfluidic diagnostic device capable of on-site quantitative nucleic acid detection directly from the blood without separate sample preparation steps. First, we prepatterned the amplification initiator [magnesium acetate (MgOAc)] on the chip to enable digital nucleic acid amplification. Second, a simplified sample preparation step is demonstrated, where the plasma is separated autonomously into 224 microwells (100 nl per well) without any hemolysis. Furthermore, self-powered microfluidic pumping without any external pumps, controllers, or power sources is accomplished by an integrated vacuum battery on the chip. This simple chip allows rapid quantitative digital nucleic acid detection directly from human blood samples (10 to 105 copies of methicillin-resistant Staphylococcus aureus DNA per microliter, ~30 min, via isothermal recombinase polymerase amplification). These autonomous, portable, lab-on-chip technologies provide promising foundations for future low-cost molecular diagnostic assays. PMID:28345028
Hultén, C; Frössling, J; Chenais, E; Sternberg Lewerin, S
2013-10-01
Sweden experienced its first outbreak of bluetongue virus (BTV) infection beginning in September 2008. Mandatory vaccination with an inactivated vaccine (BTVPUR Alsap8; Merial, Lyon, France) began 2 days after bluetongue was confirmed in the country. The aim of this study was to investigate whether the goal of 80% seroconversion by the susceptible population within the vaccination area was met during the initial phase of the Swedish vaccination campaign and whether there were discrepancies between subpopulations. Milk or blood samples were collected from 274 cattle randomly selected from the vaccinated population. Blood samples were also collected from ten ewes on each of 28 randomly selected vaccinated herds. The vaccination campaign in Sweden may be regarded as successful, as measured by apparent seroprevalence in the vaccinated population. The overall apparent seroprevalence was 77%, and in cattle, which constituted the majority of the susceptible population, the apparent seroprevalence was 82%. Factors that influenced the titres after vaccination were as follows: (i) the time span between vaccination and sampling and (ii) the age of the animals. © 2012 Blackwell Verlag GmbH.
Akuffo, R; Brandful, J A M; Zayed, A; Adjei, A; Watany, N; Fahmy, N T; Hughes, R; Doman, B; Voegborlo, S V; Aziati, D; Pratt, D; Awuni, J A; Adams, N; Dueger, E
2016-07-08
Crimean-Congo Haemorrhagic Fever Virus (CCHFV) is a zoonotic virus transmitted by Ixodid ticks and causes Crimean-Congo hemorrhagic fever (CCHF) disease in humans with up to 50 % mortality rate. Freshly slaughtered livestock at the Kumasi abattoir in the Ashanti Region of Ghana were examined for the presence of ticks once a month over a 6-month period from May to November 2011. The ticks were grouped into pools by species, sex, and animal source. CCHFV was detected in the ticks using reverse transcription PCR. Blood samples were collected from enrolled abattoir workers at initiation, and from those who reported fever in a preceding 30-day period during monthly visits 2-5 months after initiation. Six months after initiation, all participants who provided baseline samples were invited to provide blood samples. Serology was performed using enzyme linked immunosorbent assay (ELISA). Demographic and epidemiological data was also obtained from enrolled participants using a structured questionnaire. Of 428 freshly slaughtered animals comprising 130 sheep, 149 cattle, and 149 goats examined, 144 ticks belonging to the genera Ambylomma, Hyalomma and Boophilus were identified from 57 (13.3 %): 52 (34.9 %), 4 (3.1 %) and 1 (0.7 %) cattle, sheep and goat respectively. Of 97 tick pools tested, 5 pools comprising 1 pool of Hyalomma excavatum and 4 pools of Ambylomma variegatum, collected from cattle, were positive for CCHFV. Of 188 human serum samples collected from 108 abattoir workers, 7 (3.7 %) samples from 6 persons were anti-CCHF IgG positive with one of them also being CCHF IgM positive. The seroprevalence of CCHFV identified in this study was 5.7 %. This study detected human exposure to CCHF virus in slaughterhouse workers and also identified the CCHF virus in proven vectors (ticks) of Crimean Congo hemorrhagic fever in Ghana. The CCHFV was detected only in ticks collected from cattle, one of the livestock known to play a role in the amplification of the CCHF virus.
Lim, Hyunjung; Nam, Jeonghun; Xue, Shubin; Shin, Sehyun
2011-01-01
Even though blood coagulation can be tested by various methods and techniques, the effect of RBC aggregation on blood coagulation is not fully understood. The present study monitored clot formation in a microchip-based light transmission aggregometer. Citrated blood samples with and without the addition of calcium ion solution were initially disaggregated by rotating a stirrer in the microchip. After abrupt stop of the rotating stirrer, the transmitted light intensity over time was recorded. The syllectogram (light intensity vs. time graph) manifested a rapid increase that is associated with RBC aggregation followed by a decrease that is associated with blood coagulation. The time to reach the peak point was used as a new index of coagulation time (CT) and ranged from 200 to 500 seconds in the present measurements. The CT was inversely proportional to the concentration of fibrinogen, which enhances RBC aggregation. In addition, the CT was inversely proportional to the hematocrit, which is similar to the case of the prothrombin time (PT), as measured by a commercial coagulometer. Thus, we carefully concluded that RBC aggregation should be considered in tests of blood coagulation.
Assessing the depth of isoflurane anaesthesia during cardiopulmonary bypass.
Ng, Ka Ting; Alston, R Peter; Just, George; McKenzie, Chris
2018-03-01
Bispectral index (BIS) and monitoring of end-tidal concentration may be associated with a reduction in the incidence of awareness during volatile-based general anaesthesia. An analogue of end-tidal concentration during cardiopulmonary bypass (CPB) is measuring exhausted isoflurane concentration from the oxygenator as an estimate to blood and, so, brain concentration. The aim of this study was to determine the relationships between oxygenator exhaust and blood concentrations of isoflurane and the BIS score during CPB when administering isoflurane into the sweep gas supply to the oxygenator. Seventeen patients undergoing elective cardiac surgery using CPB and isoflurane with BIS monitoring were recruited in a single-centre university hospital. Isoflurane gas was delivered via a calibrated vaporiser at the beginning of anaesthetic induction. Radial arterial blood samples were collected after the initiation of CPB and before aortic cross-clamping, which were analysed for isoflurane by gas chromatography and mass spectrometry. The BIS score and the concentration of exhausted isoflurane from the oxygenator membrane, as measured by an anaesthetic gas analyser, were recorded at the time of blood sampling. The mean duration of anaesthetic induction to arterial blood sampling was 90 min (95%CI: 80,100). On CPB, the median BIS was 39 (range, 7-43) and the mean oxygenator exhaust isoflurane concentration was 1.24 ± 0.21%. No significant correlation was demonstrated between BIS with arterial isoflurane concentration (r=-0.19, p=0.47) or oxygenator exhaust isoflurane concentration (r=0.07, p=0.80). Mixed-venous blood temperature was moderately correlated to BIS (r=0.50, p=0.04). Oxygenator exhaust isoflurane concentration was moderately, positively correlated with its arterial concentration (r=0.64, p<0.01). In conclusion, in patients undergoing heart surgery with CPB, the findings of this study indicate that, whilst oxygenator exhaust concentrations were significantly associated with arterial concentrations of isoflurane, neither had any association with the BIS scores, whereas body temperature has moderate positive correlation.
DNA methylation age is elevated in breast tissue of healthy women.
Sehl, Mary E; Henry, Jill E; Storniolo, Anna Maria; Ganz, Patricia A; Horvath, Steve
2017-07-01
Limited evidence suggests that female breast tissue ages faster than other parts of the body according to an epigenetic biomarker of aging known as the "epigenetic clock." However, it is unknown whether breast tissue samples from healthy women show a similar accelerated aging effect relative to other tissues, and what could drive this acceleration. The goal of this study is to validate our initial finding of advanced DNA methylation (DNAm) age in breast tissue, by directly comparing it to that of peripheral blood tissue from the same individuals, and to do a preliminary assessment of hormonal factors that could explain the difference. We utilized n = 80 breast and 80 matching blood tissue samples collected from 40 healthy female participants of the Susan G. Komen Tissue Bank at the Indiana University Simon Cancer Center who donated these samples at two time points spaced at least a year apart. DNA methylation levels (Illumina 450K platform) were used to estimate the DNAm age. DNAm age was highly correlated with chronological age in both peripheral blood (r = 0.94, p < 0.0001) and breast tissues (r = 0.86, p < 0.0001). A measure of epigenetic age acceleration (age-adjusted DNAm Age) was substantially increased in breast relative to peripheral blood tissue (p = 1.6 × 10 -11 ). The difference between DNAm age of breast and blood decreased with advancing chronologic age (r = -0.53, p = 4.4 × 10 -4 ). Our data clearly demonstrate that female breast tissue has a higher epigenetic age than blood collected from the same subject. We also observe that the degree of elevation in breast diminishes with advancing age. Future larger studies will be needed to examine associations between epigenetic age acceleration and cumulative hormone exposure.
Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.
Mullins, Garrett R; Bruns, David E
2017-10-01
Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (p<0.01), LD (p<0.01), and potassium (p<0.02) in plasma. Removing air space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (p<0.02 vs conventionally filled collection tube). Clotted blood developed less foaming during PTS transport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (p<0.03) in serum than in plasma after PTS sample transport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Leidinger, Petra; Backes, Christina; Rheinheimer, Stefanie; Keller, Andreas; Meese, Eckart
2015-01-01
Background Circulating microRNAs (miRNAs) from blood are increasingly recognized as biomarker candidates for human diseases. Clinical routine settings frequently include blood sampling in tubes with EDTA as anticoagulant without considering the influence of phlebotomy on the overall miRNA expression pattern. We collected blood samples from six healthy individuals each in an EDTA blood collection tube. Subsequently, the blood was transferred into PAXgeneTM tubes at three different time points, i.e. directly (0 min), 10 min, and 2 h after phlebotomy. As control blood was also directly collected in PAXgeneTM blood RNA tubes that contain a reagent to directly lyse blood cells and stabilize their content. For all six blood donors at the four conditions (24 samples) we analyzed the abundance of 1,205 miRNAs by human Agilent miRNA V16 microarrays. Results While we found generally a homogenous pattern of the miRNA abundance in all 24 samples, the duration of the EDTA treatment appears to influence the miRNA abundance of specific miRNAs. The most significant changes are observed after longer EDTA exposition. Overall, the impact of the different blood sample conditions on the miRNA pattern was substantially lower than intra-individual variations. While samples belonging to one of the six individuals mostly cluster together, there was no comparable clustering for any of the four tested blood sampling conditions. The most affected miRNA was miR-769-3p that was not detected in any of the six PAXgene blood samples, but in all EDTA 2h samples. Accordingly, hsa-miR-769-3p was also the only miRNA that showed a significantly different abundance between the 4 blood sample conditions by an ANOVA analysis (Benjamini-Hochberg adjusted p-value of 0.003). Validation by qRT-PCR confirmed this finding. Conclusion The pattern of blood-borne miRNA abundance is rather homogenous between the four tested blood sample conditions of six blood donors. There was a clustering between the miRNA profiles that belong to a specific blood donor, but not between any of the four tested blood sampling conditions. The results show a limited overall impact of the blood sampling conditions on the miRNA pattern. Notwithstanding, the abundance of single miRNAs can be significantly altered by different blood sampling conditions. PMID:26599228
Wolski, Stanisław; Lewandowska, Ewa; Kurzejamska-Parafiniuk, Małgorzata
2013-01-01
Polish law forbids persons to drive under the influence of intoxicating substances, and those after the use of substances producing effects similar to alcohol. Therefore, there is a need to give an opinion based on a blood test, to establish whether or not the person from whom the blood was taken was under the influence of an intoxicating substance or after use of the drug while driving. Some authors reported that the final opinion should take into account chemical and toxicology test results identifying the parent compound and/or the metabolite only, but also the sampling time of the material to be analyzed in relation to the driving time, the result of the medical examination conducted prior to the collection of material for analysis, and the results of screening tests executed at the scene. Circumstances relating to the event, the findings and observations of third parties, and the testimony of the suspect are also relevant. The aim of this study was to evaluate the results of the medical examination in the evaluation of cases concerning driving by persons who were potentially under the influence of amphetamine and its analogs, or delta9-tetrahydrocannabinol, (delta9-THC) and conformity assessment of these results with the results of blood tests. An additional aim was to determine the factors considered by doctors when making their evaluation of patient's condition. The study group consisted of 350 persons suspected of driving while under the influence of amphetamine and its analogs, and/or delta9-THC, from whom blood samples were taken to test amphetamine content or its analogues and/or delta9-tetrahydrocannabinol. Blood tests were carried out according to the existing procedure developed by the department. Blood samples were initially analyzed with immunochemical methods. Positive preliminary results were verified by gas chromatography-mass spectrometry. Statistical analysis was conducted with independent tests for multi-way tables, i.e. the Pearson chi2 test and the 2 x 2 tables Yates' correction was used for the low numbers. Comparison of mean concentrations of amphetamine and delta9-THC in the blood was performed using the U Mann-Whitney test. The analysis revealed a significant correlation between the symptoms and the results of the chemical-toxicological blood tests for mood only. There was no significant correlation between the results of toxicological and physical elements contained in the protocol of blood collection as the skin's appearance, speech, heart rate, pupil, pupil reaction to light, walking, lifting objects off the ground, the Romberg test, the finger-to-nose test and orientation in the space time environment. In the analysis of the relationship between the medical assessment and physical elements significant relationships with the assessment of mood, pupils, pupil reaction to light and gait were found. A significant correlation between the prevalence of symptoms in terms of any/none and medical evaluation was found. 1. Preliminary medical examination based on the blood sampling protocol has no practical importance for determining whether a person is tested under the influence of amphetamines or its analogues and/or delta9-THC. 2. The confirmation of the state "under the influence of narcotics or psychotropics" should only be based on blood test results. 3. Doctors, when completing the blood collection report, are often guided by factors other than the test results when making assessment. 4. The low utility of the medical examination is affected by lack of standardization of test items. Doctors often find symptoms in a subjective manner.
Frequency and causes of infectious abortion in a dairy herd in Queretaro, Mexico.
Escamilla, H Patricia; Martínez, M José Juan; Medina, C Mario; Morales, S Elizabeth
2007-10-01
The objective of this study was to determine the frequency of infectious bovine abortion and to identify some of its causes, specifically brucellosis, leptospirosis, bovine viral diarrhea, infectious bovine rhinotracheitis, and neosporosis. The study was carried out in a dairy herd in the state of Queretaro, Mexico, between September 2002 and March 2003. At the beginning of the study, blood samples were taken from a random 33% of the 300 lactating or pregnant cows; antibodies against Leptospira interrogans were the most commonly identified, in 91% of the 99 samples. Blood samples were also taken 14 to 28 d after the 26 subsequent abortions in the herd in the 6-mo study period, as well as from 22 cows that had not aborted within 5 d after the abortions in the other group. Seroconversion was most frequent for L. hardjo, occurring in 8 (67%) of the 12 dams that aborted after the initial serologic sampling and for which paired serum samples were therefore available. Of the 16 collected fetuses, 10 had histologic lesions suggesting infection in various organs, the features correlating with the serologic results for the dams in 7 cases. Thus, the abortions may have been caused by more than 1 infectious agent.
Frequency and causes of infectious abortion in a dairy herd in Queretaro, Mexico
Escamilla, H. Patricia; Martínez, M. José Juan; Medina, C. Mario; Morales, S. Elizabeth
2007-01-01
The objective of this study was to determine the frequency of infectious bovine abortion and to identify some of its causes, specifically brucellosis, leptospirosis, bovine viral diarrhea, infectious bovine rhinotracheitis, and neosporosis. The study was carried out in a dairy herd in the state of Queretaro, Mexico, between September 2002 and March 2003. At the beginning of the study, blood samples were taken from a random 33% of the 300 lactating or pregnant cows; antibodies against Leptospira interrogans were the most commonly identified, in 91% of the 99 samples. Blood samples were also taken 14 to 28 d after the 26 subsequent abortions in the herd in the 6-mo study period, as well as from 22 cows that had not aborted within 5 d after the abortions in the other group. Seroconversion was most frequent for L. hardjo, occurring in 8 (67%) of the 12 dams that aborted after the initial serologic sampling and for which paired serum samples were therefore available. Of the 16 collected fetuses, 10 had histologic lesions suggesting infection in various organs, the features correlating with the serologic results for the dams in 7 cases. Thus, the abortions may have been caused by more than 1 infectious agent. PMID:17955907
Factors affecting blood sample haemolysis: a cross-sectional study.
Barnard, Ed B G; Potter, David L; Ayling, Ruth M; Higginson, Ian; Bailey, Andrew G; Smith, Jason E
2016-04-01
To determine the effect of blood sampling through an intravenous catheter compared with a needle in Emergency Department blood sampling. We undertook a prospective, cross-sectional study in a UK university teaching hospital Emergency Department. A convenience sample of 985 patients who required blood sampling via venepuncture was collected. A total of 844 complete sets of data were analysed. The median age was 63 years, and 57% of patients were male. The primary outcome measure was the incidence of haemolysis in blood samples obtained via a needle compared with samples obtained via an intravenous catheter. Secondary outcome measures defined the effect on sample haemolysis of the side of the patient the sample was obtained from, the anatomical location of sampling, the perceived difficulty in obtaining the sample, the order of sample tubes collected, estimated tourniquet time and bench time. Data were analysed with logistic regression, and expressed as odds ratios (95% confidence intervals; P-values). Blood samples obtained through an intravenous catheter were more likely to be haemolysed than those obtained via a needle, odds ratio 5.63 (95% confidence interval 2.49-12.73; P<0.001). Blood sampling via an intravenous catheter was significantly associated with an increase in the likelihood of sample haemolysis compared with sampling with a needle. Wherever practicable, blood samples should be obtained via a needle in preference to an intravenous catheter. Future research should include both an economic evaluation, and staff and patient satisfaction of separating blood sampling and intravenous catheter placement.
NASA Astrophysics Data System (ADS)
Kehayias, Christopher; Kybert, Nicholas; Yodh, Jeremy; Johnson, A. T. Charlie
Carbon nanotubes are low-dimensional materials that exhibit remarkable chemical and bio-sensing properties and have excellent compatibility with electronic systems. Here, we present a study that uses an electronic olfaction system based on a large array of DNA-carbon nanotube field effect transistors vapor sensors to analyze the VOCs of blood plasma samples collected from patients with malignant ovarian cancer, patients with benign ovarian lesions, and age-matched healthy subjects. Initial investigations involved coating each CNT sensor with single-stranded DNA of a particular base sequence. 10 distinct DNA oligomers were used to functionalize the carbon nanotube field effect transistors, providing a 10-dimensional sensor array output response. Upon performing a statistical analysis of the 10-dimensional sensor array responses, we showed that blood samples from patients with malignant cancer can be reliably differentiated from those of healthy control subjects with a p-value of 3 x 10-5. The results provide preliminary evidence that the blood of ovarian cancer patients contains a discernable volatile chemical signature that can be detected using DNA-CNT nanoelectronic vapor sensors, a first step towards a minimally invasive electronic diagnostic technology for ovarian cancer.
Establishing a Southern Swedish Malignant Melanoma OMICS and biobank clinical capability
2013-01-01
Background The objectives and goals of the Southern Swedish Malignant Melanoma (SSMM) are to develop, build and utilize cutting edge biobanks and OMICS platforms to better understand disease pathology and drug mechanisms. The SSMM research team is a truly cross-functional group with members from oncology, surgery, bioinformatics, proteomics, and genomics initiatives. Within the research team there are members who daily diagnose patients with suspect melanomas, do follow-ups on malignant melanoma patients and remove primary or metastatic lesions by surgery. This inter-disciplinary clinical patient care ensures a competence build as well as a best practice procedure where the patient benefits. Methods Clinical materials from patients before, during and after treatments with clinical end points are being collected. Tissue samples as well as bio-fluid samples such as blood fractions, plasma, serum and whole blood will be archived in 384-high density sample tube formats. Standardized approaches for patient selections, patient sampling, sample-processing and analysis platforms with dedicated protein assays and genomics platforms that will hold value for the research community are used. The patient biobank archives are fully automated with novel ultralow temperature biobank storage units and used as clinical resources. Results An IT-infrastructure using a laboratory information management system (LIMS) has been established, that is the key interface for the research teams in order to share and explore data generated within the project. The cross-site data repository in Lund forms the basis for sample processing, together with biological samples in southern Sweden, including blood fractions and tumor tissues. Clinical registries are associated with the biobank materials, including pathology reports on disease diagnosis on the malignant melanoma (MM) patients. Conclusions We provide data on the developments of protein profiling and targeted protein assays on isolated melanoma tumors, as well as reference blood standards that is used by the team members in the respective laboratories. These pilot data show biobank access and feasibility of performing quantitative proteomics in MM biobank repositories collected in southern Sweden. The scientific outcomes further strengthen the build of healthcare benefit in the complex challenges of malignant melanoma pathophysiology that is addressed by the novel personalized medicines entering the market. PMID:23445834
Establishing a Southern Swedish Malignant Melanoma OMICS and biobank clinical capability.
Welinder, Charlotte; Jönsson, Göran; Ingvar, Christian; Lundgren, Lotta; Olsson, Håkan; Breslin, Thomas; Végvári, Akos; Laurell, Thomas; Rezeli, Melinda; Jansson, Bo; Baldetorp, Bo; Marko-Varga, György
2013-02-27
The objectives and goals of the Southern Swedish Malignant Melanoma (SSMM) are to develop, build and utilize cutting edge biobanks and OMICS platforms to better understand disease pathology and drug mechanisms. The SSMM research team is a truly cross-functional group with members from oncology, surgery, bioinformatics, proteomics, and genomics initiatives. Within the research team there are members who daily diagnose patients with suspect melanomas, do follow-ups on malignant melanoma patients and remove primary or metastatic lesions by surgery. This inter-disciplinary clinical patient care ensures a competence build as well as a best practice procedure where the patient benefits. Clinical materials from patients before, during and after treatments with clinical end points are being collected. Tissue samples as well as bio-fluid samples such as blood fractions, plasma, serum and whole blood will be archived in 384-high density sample tube formats. Standardized approaches for patient selections, patient sampling, sample-processing and analysis platforms with dedicated protein assays and genomics platforms that will hold value for the research community are used. The patient biobank archives are fully automated with novel ultralow temperature biobank storage units and used as clinical resources. An IT-infrastructure using a laboratory information management system (LIMS) has been established, that is the key interface for the research teams in order to share and explore data generated within the project. The cross-site data repository in Lund forms the basis for sample processing, together with biological samples in southern Sweden, including blood fractions and tumor tissues. Clinical registries are associated with the biobank materials, including pathology reports on disease diagnosis on the malignant melanoma (MM) patients. We provide data on the developments of protein profiling and targeted protein assays on isolated melanoma tumors, as well as reference blood standards that is used by the team members in the respective laboratories. These pilot data show biobank access and feasibility of performing quantitative proteomics in MM biobank repositories collected in southern Sweden. The scientific outcomes further strengthen the build of healthcare benefit in the complex challenges of malignant melanoma pathophysiology that is addressed by the novel personalized medicines entering the market.
Two traffic fatalities related to the use of difluoroethane.
Broussard, L A; Brustowicz, T; Pittman, T; Atkins, K D; Presley, L
1997-11-01
The 18-year-old white male driver and 17-year-old white male passenger of an automobile were killed when their vehicle crossed the median of a 4-lane highway and collided with a minivan. A can of airbrush propellant was found in the automobile of the deceased. The only drug detected during initial toxicological analyses was 130 mg/L ethanol in the blood of the driver. When performing ethanol analysis by headspace gas chromatography, an unidentified peak was observed in the blood of both deceased. This peak was identified as difuoroethane (Freon 152), the propellant in the aerosol can found in the automobile. The concentrations of difluoroethane in the blood of the driver and passenger were 78 mg/L and 35 mg/L, respectively. Based on a literature search we believe that this is the first report of the quantitation of difluoroethane in biological samples.
Estimating the cost of blood: past, present, and future directions.
Shander, Aryeh; Hofmann, Axel; Gombotz, Hans; Theusinger, Oliver M; Spahn, Donat R
2007-06-01
Understanding the costs associated with blood products requires sophisticated knowledge about transfusion medicine and is attracting the attention of clinical and administrative healthcare sectors worldwide. To improve outcomes, blood usage must be optimized and expenditures controlled so that resources may be channeled toward other diagnostic, therapeutic, and technological initiatives. Estimating blood costs, however, is a complex undertaking, surpassing simple supply versus demand economics. Shrinking donor availability and application of a precautionary principle to minimize transfusion risks are factors that continue to drive the cost of blood products upward. Recognizing that historical accounting attempts to determine blood costs have varied in scope, perspective, and methodology, new approaches have been initiated to identify all potential cost elements related to blood and blood product administration. Activities are also under way to tie these elements together in a comprehensive and practical model that will be applicable to all single-donor blood products without regard to practice type (e.g., academic, private, multi- or single-center clinic). These initiatives, their rationale, importance, and future directions are described.
Evaluation of blood metabolites reflects presence or absence of liver abscesses in beef cattle
Macdonald, Alaina G C; Bourgon, Stéphanie L; Palme, Rupert; Miller, Stephen P; Montanholi, Yuri R
2017-01-01
Liver abscesses constitute a prominent concern regarding animal health and profitability of the beef industry. Our objective was to evaluate potential biliary and blood indicators of liver abscesses. Twenty-nine beef bulls (initially averaging 356±70.5 kg and 253±30 days of age) were fed a high-concentrate diet during a performance test of 112 days, during which blood was collected at nine time points spaced 0.5–13 days apart within 56 days before slaughter. At the abattoir, blood and bile were collected and livers were inspected for liver abscesses. Results indicated that liver abscesses are associated with elevated levels of plasma cortisol and aspartate aminotransferase, and decreased levels of albumin, cholesterol and testosterone over the period before slaughter. Based on the blood samples collected during exsanguination, the presence of liver abscesses was associated with lower concentrations of thyroxine, albumin, cholesterol and alkaline phosphatase, and is suggested to be associated with lower blood carbon dioxide (P=0.08) and lower biliary cortisol metabolites (P=0.07). Albumin and cholesterol are established indicators of hepatic function and are consistently related to the presence of liver abscesses. Identifying blood parameters that predict liver abscesses has practical implications for cattle husbandry and for ensuring food safety. PMID:28890789
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Benjamin, B. A.; Keil, L. C.; Sandler, H.
1984-01-01
Hemodynamic responses and antidiuretic hormone (ADH) were measured during body position changes, designed to induce central blood volume shifts in ten cardiac and one heart-lung transplant recipients, to assess the contribution of cardiac volume receptors in the control of ADH release during the initial acute phase of exposure to weightlessness. Each subject underwent 15 min of a sitting-control period (C) followed by 30 min of 6 deg headdown tilt (T) and 30 min of resumed sitting (S). Venous blood samples and cardiac dimensions were taken at 0 and 15 min of C; 5, 15, and 30 min of T; and 5, 15, and 30 min of S. Blood samples were analyzed for hematocrit, plasma osmolality, plasma renin activity (PRA), and ADH. Heart rate and blood pressure were recorded every two min. Plasma osmolality was not altered by posture changes. Mean left ventricular end-diastolic volume increased (P less than 0.05) from 90 ml in C to 106 ml in T and returned to 87 ml in S. Plasma ADH was reduced by 20 percent (P less than 0.05) with T, and returned to control levels with S. These responses were similar in six normal cardiac-innervated control subjects. These data may suggest that cardiac volume receptors are not the primary mechanism for the control of ADH release during acute central volume shifts in man.
Periodontal therapy alters gene expression of peripheral blood monocytes
Papapanou, Panos N.; Sedaghatfar, Michael H.; Demmer, Ryan T.; Wolf, Dana L.; Yang, Jun; Roth, Georg A.; Celenti, Romanita; Belusko, Paul B.; Lalla, Evanthia; Pavlidis, Paul
2009-01-01
Aims We investigated the effects of periodontal therapy on gene expression of peripheral blood monocytes. Methods Fifteen patients with periodontitis gave blood samples at four time points: 1 week before periodontal treatment (#1), at treatment initiation (baseline, #2), 6-week (#3) and 10-week post-baseline (#4). At baseline and 10 weeks, periodontal status was recorded and subgingival plaque samples were obtained. Periodontal therapy (periodontal surgery and extractions without adjunctive antibiotics) was completed within 6 weeks. At each time point, serum concentrations of 19 biomarkers were determined. Peripheral blood monocytes were purified, RNA was extracted, reverse-transcribed, labelled and hybridized with AffymetrixU133Plus2.0 chips. Expression profiles were analysed using linear random-effects models. Further analysis of gene ontology terms summarized the expression patterns into biologically relevant categories. Differential expression of selected genes was confirmed by real-time reverse transcriptase-polymerase chain reaction in a subset of patients. Results Treatment resulted in a substantial improvement in clinical periodontal status and reduction in the levels of several periodontal pathogens. Expression profiling over time revealed more than 11,000 probe sets differentially expressed at a false discovery rate of <0.05. Approximately 1/3 of the patients showed substantial changes in expression in genes relevant to innate immunity, apoptosis and cell signalling. Conclusions The data suggest that periodontal therapy may alter monocytic gene expression in a manner consistent with a systemic anti-inflammatory effect. PMID:17716309
Bio-repository of post-clinical test samples at the national cancer center hospital (NCCH) in Tokyo.
Furuta, Koh; Yokozawa, Karin; Takada, Takako; Kato, Hoichi
2009-08-01
We established the Bio-repository at the National Cancer Center Hospital in October 2002. The main purpose of this article is to show the importance and usefulness of a bio-repository of post-clinical test samples not only for translational cancer research but also for routine clinical oncology by introducing the experience of setting up such a facility. Our basic concept of a post-clinical test sample is not as left-over waste, but rather as frozen evidence of a patient's pathological condition at a particular point. We can decode, if not all, most of the laboratory data from a post-clinical test sample. As a result, the bio-repository is able to provide not only the samples, but potentially all related laboratory data upon request. The areas of sample coverage are the following: sera after routine blood tests; sera after cross-match tests for transfusion; serum or plasma submitted at a patient's clinically important time period by the physician; and samples collected by the individual investigator. The formats of stored samples are plasma or serum, dried blood spot (DBS) and buffy coat. So far, 150 218 plasmas or sera, 35 253 DBS and 536 buffy coats have been registered for our bio-repository system. We arranged to provide samples to various concerned parties under strict legal and ethical agreements. Although the number of the utilized samples was initially limited, the inquiries for sample utilization are now increasing steadily from both research and clinical sources. Further efforts to increase the benefits of the repository are intended.
Koziorowski, M; Stefańczyk-Krzymowska, S; Tabecka-Lonczyńska, A; Gilun, P; Kamiński, M
2012-01-01
Circadian and seasonal rhythms in daylight affect many physiological processes. In the eye, energy of intense visible light not only initiates a well-studied neural reaction in the retina that modulates the secretory function of the hypothalamus and pineal gland, but also activates the heme oxygenase (HO) to produce carbon monoxide (CO). This study was designed to determine whether the concentration of carbon monoxide (CO) in the ophthalmic venous blood changes depending on the phase of the day and differing extremely light intensity seasons: summer and winter. The concentration of CO in the venous blood flowing out from the nasal cavity, where heme oxygenase (HO) is expressed, but no photoreceptors, was used as a control. Sixteen mature males of a wild boar and pig crossbreed were used for this study. Samples of ophthalmic and nasal venous blood and systemic arterial and venous blood were collected repeatedly for two consecutive days during the longest days of the summer and the shortest days of the winter. The concentrations of CO in blood samples was measured using a standard addition method. During the longest days of the summer the concentration of CO in ophthalmic venous blood averaged 3.32 ± 0.71 and 3.43 ± 0.8 nmol/ml in the morning and afternoon, respectively, and was significantly higher than in the night averaging 0.89 ± 0.12 nmol/ml (p<0.001). During the shortest day of the winter CO concentration in ophthalmic venous blood was 1.11 ± 0.10 and 1.13 ± 0.14 nmol/ml during the light and nocturnal phase, respectively, and did not differ between phases, but was lower than in the light phase of the summer (p<0.01). The CO concentration in the control nasal venous blood did not differ between seasons and day phases and was lower than in ophthalmic venous blood during the summer (p<0.01) and winter (p<0.05). The results indicate that the gaseous messenger carbon monoxide is released from the eye into the ophthalmic venous blood depending on the intensity of sunlight.
NASA Astrophysics Data System (ADS)
Spradling, Emily M.; Viator, John A.
2009-02-01
Melanoma is the deadliest form of skin cancer. Although the initial malignant cells are removed, it is impossible to determine whether or not the cancer has metastasized until a secondary tumor forms that is large enough to detect with conventional imaging. Photoacoustic detection of circulating melanoma cells in the bloodstream has shown promise for early detection of metastasis that may aid in treatment of this aggressive cancer. When blood is irradiated with energy from an Nd:YAG laser at 532 nm, photoacoustic signals are created and melanoma cells can be differentiated from the surrounding cells based on waveforms produced by an oscilloscope. Before this can be used as a diagnostic technique, however, we needed to investigate several parameters. Specifically, the current technique involves the in vitro separation of blood through centrifugation to isolate and test only the white blood cell layer. Using this method, we have detected a single cultured melanoma cell among a suspension of white blood cells. However, the process could be made simpler if the plasma layer were used for detection instead of the white blood cell layer. This layer is easier to obtain after blood separation, the optical difference between plasma and melanoma cells is more pronounced in this layer than in the white blood cell layer, and the possibility that any stray red blood cells could distort the results is eliminated. Using the photoacoustic apparatus, we detected no melanoma cells within the plasma of whole blood samples spiked with cultured melanoma cells.
den Reijer, Paul Martijn; Lemmens-den Toom, Nicole; Kant, Samantha; Snijders, Susan V.; Boelens, Hélène; Tavakol, Mehri; Verkaik, Nelianne J.; van Belkum, Alex; Verbrugh, Henri A.; van Wamel, Willem J. B.
2013-01-01
Attempts to develop an efficient anti-staphylococcal vaccine in humans have so far been unsuccessful. Therefore, more knowledge of the antigens that are expressed by Staphylococcus aureus in human blood and induce an immune response in patients is required. In this study we further characterize the serial levels of IgG and IgA antibodies against 56 staphylococcal antigens in multiple serum samples of 21 patients with a S. aureus bacteremia, compare peak IgG levels between patients and 30 non-infected controls, and analyze the expression of 3626 genes by two genetically distinct isolates in human blood. The serum antibody levels were measured using a bead-based flow cytometry technique (xMAP®, Luminex corporation). Gene expression levels were analyzed using a microarray (BµG@s microarray). The initial levels and time taken to reach peak IgG and IgA antibody levels were heterogeneous in bacteremia patients. The antigen SA0688 was associated with the highest median initial-to-peak antibody fold-increase for IgG (5.05-fold) and the second highest increase for IgA (2.07-fold). Peak IgG levels against 27 antigens, including the antigen SA0688, were significantly elevated in bacteremia patients versus controls (P≤0.05). Expression of diverse genes, including SA0688, was ubiquitously high in both isolates at all time points during incubation in blood. However, only a limited number of genes were specifically up- or downregulated in both isolates when cultured in blood, compared to the start of incubation in blood or during incubation in BHI broth. In conclusion, most staphylococcal antigens tested in this study, including many known virulence factors, do not induce uniform increases in the antibody levels in bacteremia patients. In addition, the expression of these antigens by S. aureus is not significantly altered by incubation in human blood over time. One immunogenic and ubiquitously expressed antigen is the putative iron-regulated ABC transporter SA0688. PMID:23308212
Chung, Boram; Park, Chulmin; Cho, Sung-Yeon; Shin, Juyoun; Shin, Sun; Yim, Seon-Hee; Lee, Dong-Gun; Chung, Yeun-Jung
2018-02-01
Early and accurate detection of bacterial pathogens in the blood is the most crucial step for sepsis management. Gram-negative bacteria are the most common organisms causing severe sepsis and responsible for high morbidity and mortality. We aimed to develop a method for rapid multiplex identification of clinically important Gram-negative pathogens and also validated whether our system can identify Gram-negative pathogens with the cell-free plasm DNA from infected blood. We designed five MLPA probe sets targeting the genes specific to major Gram-negative pathogens (uidA and lacY for E. coli, ompA for A. baumannii, phoE for K. pneumoniae, and ecfX for P. aeruginosa) and one set targeting the CTX-M group 1 to identify the ESBL producing Gram-negative pathogens. All six target-specific peaks were clearly separated without any non-specific peaks in a multiplex reaction condition. The minimum detection limit was 100 fg of pathogen DNA. When we tested 28 Gram-negative clinical isolates, all of them were successfully identified without any non-specific peaks. To evaluate the clinical applicability, we tested seven blood samples from febrile patients. Three blood culture positive cases showed E. coli specific peaks, while no peak was detected in the other four culture negative samples. This technology can be useful for detection of major sepsis-causing, drug-resistant Gram-negative pathogens and also the major ESBL producing Gram-negatives from the blood of sepsis patients in a clinical setting. This system can help early initiation of effective antimicrobial treatment against Gram-negative pathogens for sepsis patients, which is very crucial for better treatment outcomes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Detection of parvovirus B19 DNA in blood: Viruses or DNA remnants?
Molenaar-de Backer, M W A; Russcher, A; Kroes, A C M; Koppelman, M H G M; Lanfermeijer, M; Zaaijer, H L
2016-11-01
Parvovirus B19 (B19V) DNA can be detected in blood over a long period after acute infection. Several reports associate the presence of B19V DNA with disease, irrespective of timing of the initial B19V infection. This study aims to analyze the properties of B19V DNA in blood, differentiating between bare, non-infectious strands of DNA and B19V DNA in viable virions. Ten blood donors with asymptomatic acute B19V infection were followed and sampled up to 22 months after infection. The samples were treated with and without an endonuclease and tested for B19V DNA, to distinguish between DNA in virions and naked DNA. In the acute phase of infection, high levels of B19V DNA were detected, concurrent with B19V IgM antibodies. B19V DNA apparently was encapsidated, as indicated by resistance to endonuclease degradation. Subsequently, B19V DNA remained detectable for more than one year in all donors at low levels (<10 5 IU/mL). Approximately 150days after infection B19V DNA became degradable by an endonuclease, indicating that this concerned naked DNA. In some donors a second endonuclease-resistant peak occurred. Detection of B19V DNA in blood by PCR does not necessarily imply that B19V replication takes place and that infectious B19V virions are present. We propose that remnant B19V DNA strands can be released from tissues without active replication. This finding urges to reconsider an assumed role of B19V infection mainly based on B19V DNA detection in blood, a much debated subject in clinical syndromes such as myocarditis and arthritis. Copyright © 2016 Elsevier B.V. All rights reserved.
Resting blood lactate in individuals with sickle cell disease
Petto, Jefferson; de Jesus, Jaqueline Brito; Vasques, Leila Monique Reis; Pinheiro, Renata Leão Silva; Oliveira, Aila Mascarenhas; Spinola, Kelly Aparecida Borges; Silva, Wellington dos Santos
2011-01-01
Background The most common hereditary hemoglobin disorder, affecting 20 million individuals worldwide, is sickle cell disease. The vascular obstruction resulting from the sickling of cells in this disease can produce local hypoxemia, pain crises and infarction in several tissues, including the bones, spleen, kidneys and lungs. Objective To determine red blood group genes in a Brazilian populations. Methods The present study is characterized as a case control study, with the aim of identifying the baseline blood lactate concentration in individuals with hemoglobin SS and SC diseases. One-way ANOVA with the Tukey post-test was used to analyze the results and a p-value < 0.05 was considered significant. Calculations were made using the INSTAT statistical program. The graphs were generated using the ORING program. The study sample was composed of 31 men and women residing in the city of Santo Antônio de Jesus, Bahia, Brazil. The individuals were divided into two groups: Group GC of 16 subjects who did not present with any type of structural hemoglobinopathy; and Group GE composed of 15 individuals with ages between 2 and 35 years old, who had the SS and SC genotypes. Sample analyses were performed with 3 mL of blood during fasting. Results The baseline blood lactate concentration of the SS and SC individuals was higher than that of the control group (p<0.001) with means of 4.86 ± 0.95; 3.30 ± 0.33; 1.31 ± 0.08 IU/L for SS, SC and controls, respectively. This corroborates the initial research hypothesis. Conclusion The baseline blood lactate of SS and SC individuals is 3 to 4 times higher than that of healthy subjects, probably due to the fact that these patients have a metabolic deviation to the anaerobic pathway. PMID:23284239
Vijayaraghavan, Maya; He, Guozhong; Stoddard, Pamela; Schillinger, Dean
2010-09-01
To determine prevalence of blood pressure control, hypertension, hypertension awareness, and antihypertensive treatment among adults (> 18 years old) with diabetes living in the border region between the United States of America and Mexico, and to explore variation in those variables between all adults on the Mexican side of the border ("Mexicans") and three groups on the U.S. side of the border ("all U.S. adults," "U.S.-born Hispanics," and "Mexican immigrants"). Using data from Phase I (February 2001-October 2002) of the U.S.-Mexico Border Diabetes Prevention and Control Project, a prevalence study of type 2 diabetes and its risk factors, age-adjusted prevalence of hypertension-related variables was calculated for the sample (n = 682) and differences between the border groups were examined through logistic regression. Less than one-third of the sample had controlled blood pressure (< 130/80 mm Hg), almost half had hypertension (≥140/90 mm Hg), and hypertension awareness and treatment were inadequate. After adjusting for demographics, body mass index, and access to health care, there were no differences in blood pressure control, hypertension, hypertension awareness, or treatment between Mexicans and both U.S. adults and Mexican immigrants. However, compared to Mexicans and Mexican immigrants, U.S.-born Hispanics, particularly younger individuals, had the lowest rates of blood pressure control (17.3%) and the highest rates of coexisting hypertension (54.8%). Compared to Mexicans, U.S.-born Hispanics had lower odds of controlled blood pressure (odds ratio [OR] 0.30, 95% confidence interval [CI] 0.09-0.95) and greater odds of hypertension (OR 3.75, 95% CI 1.51-9.29) and hypertension awareness (OR 6.19, 95% CI 1.46-26.15). Co-occurrence of diabetes and hypertension is a major public health problem among U.S.-Mexico border residents. The low rate of blood pressure control among various border groups, especially younger U.S.-born Hispanics, suggests that initiatives should aggressively target blood pressure control.
Heavy metal pollution in Nanchang City and its health implication on traffic policemen.
Liu, Xiaozhen; Liang, Yue; Guo, Jiangmei
2017-09-27
The purpose of this study is to evaluate the health effect of heavy metal pollution in air pollutants on traffic policemen. This study will facilitate the scientific evaluation of health status of traffic policemen. PM 10 samples were collected from industrial area, congested traffic area and residential area respectively in Nanchang City, and the concentrations of heavy metals were analyzed. The traffic policemen were examined through chest X-rays. The total of 637 urine samples and 142 blood samples have been collected, and the concentrations of Pb in samples were detected. Vehicle flux data of Nanchang City were collected from the Department of Transport's Traffic Management. Statistic analyses were carried out by statistics software of Excel 2003 and SPSS20.0, and the health effect of heavy metal pollution of PM 10 on the traffic policemen was evaluated. The discharge of pollutants from enterprises is an important reason for the high content of heavy metals in urban air pollution. With the rapid growth of urban traffic flow, Bayi Bridge becomes an important transportation hinge in Nanchang City, and the bidirectional traffic flow rate through the bridge at peak hours reached 99 vehicles per minute. The latent hazard of occupational harm on the traffic policemen caused by automobile exhaust is increasing. The concentration of Pb in the urine and blood samples from traffic policemen working in Nanchang City was 268.310 ± 177.031 and 22.873 ± 21.137 μg/L, respectively. Both results (2.04% of Pb in urine and 18.31% of Pb in blood) exceeded the highest limit of observed occupationally outdoor workers. This study provides an initial contribution for the assessment of city air pollution, esp. the health effect of heavy metal (Pb) pollution on traffic policemen.
Hemolysis associated with pneumatic tube system transport for blood samples
Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih
2014-01-01
Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830
Monitoring Theileria orientalis (Ikeda)-associated bovine anaemia in affected cattle over time.
McFadden, Amj; Hart, M; Bueno, I M; Ha, H J; Heath, Acg; Pulford, D J
2017-10-15
The aim of the study was to observe changes in haematocrit (HCT) over time in a New Zealand South Island dairy herd affected by an outbreak of Theileria-associated bovine anaemia (TABA; Ikeda). A secondary aim was to relate individual cow HCTs to the amount of Theileria orientalis Ikeda DNA present in the blood, as measured by cycle threshold values, using a quantitative PCR (qPCR). Over a 6 month period, blood samples from 19 randomly selected cattle were monitored from a herd of 600 dairy cows. The sampling interval was approximately fortnightly for the first six weeks, followed by sampling at between four and six week intervals. At the initial report of the outbreak, two from six cattle were anaemic (HCT<0.25L/L). Blood collected from 14 cattle 11 days later showed that 57% (95% CI 33-77%) of the cattle sampled were anaemic. Of the 19 cattle that went on to be monitored, 12 (63% 95% CI=41-81%) developed anaemia at some point during the period of monitoring. One of the anaemic animals did not meet the case definition for TABA Ikeda. For individual cattle, the average number of days between when cattle were first detected as anaemic and when HCT returned to normal was 53days (median=47 days, range=6-92 days). At the point of notification the amount of T. orientalis Ikeda DNA in the blood of the six cattle tested was low (Cq median=36), but 11days later the amount of DNA in blood of 14 additional cows tested was relatively high (Cq median=24). Levels of all 19 cows monitored continued to remain moderately high through the period of testing (Cq median=29). This was despite a general improvement in the HCT of affected cattle. In four of the 15 cattle positive to T. orientalis Ikeda where blood fractions (plasma and whole blood) were tested, it appeared that T. orientalis Ikeda (as measured by qPCR) dropped more rapidly in plasma fractions than in whole blood at the point that HCT started to return to normal levels. Despite the assumption that tick populations were low in the Canterbury region of the South Island the impact of TABA (proportion of herd affected and the average period that animals remained anaemic) on the case herd was still relatively high. Copyright © 2017 Elsevier B.V. All rights reserved.
Design of point-of-care (POC) microfluidic medical diagnostic devices
NASA Astrophysics Data System (ADS)
Leary, James F.
2018-02-01
Design of inexpensive and portable hand-held microfluidic flow/image cytometry devices for initial medical diagnostics at the point of initial patient contact by emergency medical personnel in the field requires careful design in terms of power/weight requirements to allow for realistic portability as a hand-held, point-of-care medical diagnostics device. True portability also requires small micro-pumps for high-throughput capability. Weight/power requirements dictate use of super-bright LEDs and very small silicon photodiodes or nanophotonic sensors that can be powered by batteries. Signal-to-noise characteristics can be greatly improved by appropriately pulsing the LED excitation sources and sampling and subtracting noise in between excitation pulses. The requirements for basic computing, imaging, GPS and basic telecommunications can be simultaneously met by use of smartphone technologies, which become part of the overall device. Software for a user-interface system, limited real-time computing, real-time imaging, and offline data analysis can be accomplished through multi-platform software development systems that are well-suited to a variety of currently available cellphone technologies which already contain all of these capabilities. Microfluidic cytometry requires judicious use of small sample volumes and appropriate statistical sampling by microfluidic cytometry or imaging for adequate statistical significance to permit real-time (typically < 15 minutes) medical decisions for patients at the physician's office or real-time decision making in the field. One or two drops of blood obtained by pin-prick should be able to provide statistically meaningful results for use in making real-time medical decisions without the need for blood fractionation, which is not realistic in the field.
Vilanova, María Belén; Falguera, Mireia; Marsal, Josep Ramon; Rubinat, Esther; Alcubierre, Núria; Catelblanco, Esmeralda; Granado-Casas, Minerva; Miró, Neus; Molló, Àngels; Mata-Cases, Manel; Franch-Nadal, Josep; Mauricio, Didac
2017-01-01
Purpose The Mollerussa prospective cohort was created to study pre-diabetes in a population-based sample from the primary care setting in the semirural area of Pla d’Urgell in Catalonia (Spain). The aims of the study were to assess the prevalence of pre-diabetes in our population, the likelihood to develop overt diabetes over time and to identify risk factors associated with the progression of the condition. Participants The cohort includes 594 subjects randomly selected between March 2011 and July 2014 from our primary care population, who were older than 25 years, consented to participate and did not have a recorded diagnosis of diabetes. Findings to date At baseline, we performed a clinical interview to collect demographic, clinical and lifestyle (including a nutritional survey) characteristics; carotid ultrasound imaging to assess subclinical cardiovascular disease was also performed, and a blood sample was collected, with an overall <5% rate of missing data. An additional blood draw was performed 12 months after initial recruitment to reassess laboratory results in patients initially identified as having pre-diabetes, with an 89.6% retention rate. Several studies investigating various hypotheses are currently ongoing. Future plans All subjects recruited during the cohort creation will be followed long-term through annual extraction of data from health records stored in the electronic Clinical station in Primary Care database. The Mollerussa cohort will thus be a sound population-based sample for multiple future research projects to generate insights into the epidemiology and natural history of pre-diabetes in Spain. PMID:28606902
Burtis, C.A.; Johnson, W.F.; Walker, W.A.
1985-08-05
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.
Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.
1988-01-01
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.
Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros.
Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N; Payne, Junaidi
2013-02-01
To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA(®) blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases.
Srinivasan, Balaji; O'Dell, Dakota; Finkelstein, Julia L; Lee, Seoho; Erickson, David; Mehta, Saurabh
2018-01-15
Iron deficiency (ID) is an urgent public health problem that has devastating effects on maternal and child health. However, due to poor access and affordability, screening and diagnosis for ID is often limited to proxy hemoglobin measurements alone. Here, we report the development and validation of ironPhone, a mobile-device coupled portable diagnostics for quantification of serum ferritin concentrations, an iron status biomarker, within a few minutes, from a drop of fingerprick blood. The ironPhone diagnostic platform comprises of a smartphone accessory, an app, and a disposable lateral flow immunoassay test strip to quantify serum ferritin. For initial validation in the lab, we optimized and evaluated the performance of ironPhone with known ferritin concentrations in spiked buffer and serum samples. Following lab validation, we performed a human validation by collecting fingerprick whole blood samples from 20 participants to assess iron status using ironPhone and compared the results with the laboratory standard IMMULITE 2000 analyzer. Findings from the ironPhone for the buffer and spiked serum samples provided a calibration curve with R 2 values of 0.97 (n=27) and 0.93 (n=12), respectively. On comparison with the laboratory standard IMMULITE analyzer in whole blood samples, a correlation of 0.92 (P<0.0001) was observed with a sensitivity of over 90% for predicting ID (ferritin<15.0µg/L) via the ironPhone, demonstrating its promise for iron status assessment at the point-of-care. Copyright © 2017 Elsevier B.V. All rights reserved.
The level of serotonin in the superficial masseter muscle in relation to local pain and allodynia.
Ernberg, M; Hedenberg-Magnusson, B; Alstergren, P; Kopp, S
1999-01-01
The aim of this study was to investigate if serotonin is present in the human masseter muscle and if so, whether it is involved in the modulation of local muscle pain or allodynia. Thirty-five patients with pain and tenderness of the masseter muscle as well as ten healthy individuals were included in the study. Of the patients, 18 suffered from fibromyalgia and 17 had localized myalgia, e.g. myofascial pain in the temporomandibular system. The participants were examined clinically with special consideration to the masseter muscle and the pressure pain threshold as well as tolerance levels of this muscle were assessed. Intramuscular microdialysis was performed in order to sample serotonin and a venous blood sample was collected for analysis of the serum level of serotonin. Serotonin was present in the masseter muscle and the level was significantly higher in the initial sample than in the sample collected during steady state. The level of serotonin in the masseter muscle in relation to the level of serotonin in the blood serum was calculated. This fraction of serotonin was higher in the patients with fibromyalgia than in healthy individuals and high level of serotonin was associated with pain as well as allodynia of the masseter muscle. In conclusion, the results of this study show that serotonin is present in the human masseter muscle both immediately following puncture and in a subsequent steady state and that it is associated with pain and allodynia. The origin of the serotonin seems partly to be the blood, but our results indicate that peripheral release also occurs.
Debey-Pascher, Svenja; Hofmann, Andrea; Kreusch, Fatima; Schuler, Gerold; Schuler-Thurner, Beatrice; Schultze, Joachim L.; Staratschek-Jox, Andrea
2011-01-01
Microarray-based transcriptome analysis of peripheral blood as surrogate tissue has become an important approach in clinical implementations. However, application of gene expression profiling in routine clinical settings requires careful consideration of the influence of sample handling and RNA isolation methods on gene expression profile outcome. We evaluated the effect of different sample preservation strategies (eg, cryopreservation of peripheral blood mononuclear cells or freezing of PAXgene-stabilized whole blood samples) on gene expression profiles. Expression profiles obtained from cryopreserved peripheral blood mononuclear cells differed substantially from those of their nonfrozen counterpart samples. Furthermore, expression profiles in cryopreserved peripheral blood mononuclear cell samples were found to undergo significant alterations with increasing storage period, whereas long-term freezing of PAXgene RNA stabilized whole blood samples did not significantly affect stability of gene expression profiles. This report describes important technical aspects contributing toward the establishment of robust and reliable guidance for gene expression studies using peripheral blood and provides a promising strategy for reliable implementation in routine handling for diagnostic purposes. PMID:21704280
Evaluating the Effects of Stressors on Immune Function during Simulated Dives in Marine Mammals
2014-09-30
Physiology and Stressors on Immune Cell Function in a Deep Diving Monodontid and Three Shallow Diving Phocid Species. PhD Dissertation, University...Research Permit No. 14245). Blood samples were initially processed in the field and shipped back to Mystic Aquarium in LN dry shippers for hormone...of damage from inflammatory processes . Values were returned to control levels suggesting the effects of a dive are not long lasting. That results for
2016-10-01
Study (PASS). We are in the process of evaluating these three biomarker panels in tissue, blood, and urine samples with well annotated clinical and...impacting both the initial choice of therapy and decision-making during AS. The objective of the study is to utilize analytically validated assays that...predict reclassification from Gleason 6 cancer to Gleason 7 or greater. The analysis plan was determined before specimens were selected for the study
Ramsay, Edward; Sadler, Ryan; Rush, Robert; Seimon, Tracie; Tomaszewicz, Ania; Fleetwood, Ellen A; McAloose, Denise; Wilkes, Rebecca P
2016-06-01
Three methods for delivering a live attenuated canine distemper virus (CDV) vaccine to domestic cats ( Felis catus ) were investigated, as models for developing vaccination protocols for tigers (Panthera tigris). Twenty domestic cats were randomly divided into four treatment groups: saline injection (negative controls); and oral, intranasal, and subcutaneous vaccinates. Cats were injected with saline or a CDV vaccine (Nobivac DP, Merck) at wk 0 and 4. Blood and nasal swabs were collected at wk 0 (prior to the initial vaccination) and weekly thereafter for 9 wk. Urine samples were collected on wk 1 to 9 after initial vaccination. Forty-nine weeks following the initial vaccination series, three cats from the subcutaneous group and three cats from the intranasal group were revaccinated. Blood was collected immediately prior, and 7 and 21 days subsequent to revaccination. Nasal swabs and urine samples were collected from each cat prior to wk 49 revaccination and daily for 7 days thereafter. Nasal swabs and urine were analyzed by quantitative PCR for vaccine virus presence. Sera were tested for CDV antibodies by virus neutralization. All cats were sero-negative for CDV antibodies at the beginning of the study, and saline-injected cats remained sero-negative throughout the study. A dramatic anamnestic response was seen following wk 4 subcutaneous vaccinations, with titers peaking at wk 6 (geometric mean = 2,435.5). Following wk 49 revaccination, subcutaneous vaccinates again mounted impressive titers (wk 52 geometric mean = 2,048). Revaccination of the intranasal group cats at wk 49 produced a small increase in titers (wk 52 geometric mean = 203). CDV viral RNA was detected in six nasal swabs but no urine samples, demonstrating low viral shedding postvaccination. The strong antibody response to subcutaneous vaccination and the lack of adverse effects suggest this vaccine is safe and potentially protective against CDV infection in domestic cats.
Dog Erythrocyte Antigen 1 (DEA 1): Mode of Inheritance and Initial Characterization
Polak, Klaudia; Acierno, Michelle; Raj, Karthik; Mizukami, Keijiro; Siegel, Don L.; Giger, Urs
2015-01-01
Background The Dog Erythrocyte Antigen (DEA) 1 blood group system remains poorly defined. Objectives The purpose of the study was to determine the DEA 1 mode of inheritance and to characterize the DEA 1 antigen and alloantibodies. Animals Canine research colony families, clinic canine patients, and DEA 1.2+ blood bank dogs were studied. Methods Canine blood was typed by flow cytometry and immunochromatographic strips using anti-DEA 1 monoclonal antibodies. Gel column experiments with polyclonal and immunoblotting with monoclonal anti-DEA 1 antibodies were performed to analyze select samples. Cross-reactivity of human typing reagents against canine RBCs and one monoclonal anti-DEA 1 antibody against human RBC panels was assessed. Results Typing of 12 families comprising 144 dogs indicated an autosomal dominant inheritance with ≥4 alleles: DEA 1− (0) and DEA 1+ weak (1+), intermediate (2+) and strong (3+ and 4+). Samples from 6 dogs previously typed as DEA 1.2+ were typed as DEA 1+ or DEA 1− using monoclonal antibodies. Human typing reagents produced varied reactions in tube agglutination experiments against DEA 1+ and DEA 1− RBCs. Polypeptide bands were not detected on immunoblots using a monoclonal anti-DEA 1 antibody, therefore the anti-DEA 1 antibody may be specific for conformational epitopes lost during denaturation. Conclusions The autosomal dominant inheritance of DEA 1 with ≥4 alleles indicates a complex blood group system; the antigenicity of each DEA 1+ type will need to be determined. The biochemical nature of the DEA 1 antigen(s) appears different from human blood group systems tested. PMID:26291052
NASA Astrophysics Data System (ADS)
Villanueva, Yolanda; Hondebrink, Erwin; Petersen, Wilma; Steenbergen, Wiendelt
2015-03-01
A method for simultaneously measuring the absorption coefficient μa and Grüneisen parameter Γ of biological absorbers in photoacoustics is designed and implemented using a coupled-integrating sphere system. A soft transparent tube with inner diameter of 0.58mm is used to mount the liquid absorbing sample horizontally through the cavity of two similar and adjacent integrating spheres. One sphere is used for measuring the sample's μa using a continuous halogen light source and a spectrometer fiber coupled to the input and output ports, respectively. The other sphere is used for simultaneous photoacoustic measurement of the sample's Γ using an incident pulsed light with wavelength of 750nm and a flat transducer with central frequency of 5MHz. Absolute optical energy and pressure measurements are not necessary. However, the derived equations for determining the sample's μa and Γ require calibration of the setup using aqueous ink dilutions. Initial measurements are done with biological samples relevant to biomedical imaging such as human whole blood, joint and cyst fluids. Absorption of joint and cyst fluids is enhanced using a contrast agent like aqueous indocyanine green dye solution. For blood sample, measured values of μa = 0.580 +/- 0.016 mm-1 and Γ = 0.166 +/- 0.006 are within the range of values reported in literature. Measurements with the absorbing joint and cyst fluid samples give Γ values close to 0.12, which is similar to that of water and plasma.
Baliarsingh, S; Jaiswal, M
2014-02-01
Potassium levels in stored blood bags increases as they age. Hyperkalemia in transfused blood has undesirable cardiac effects. Within a 19-month period, baseline and weekly samples from 15 CPDA-1 whole blood bags were collected till 28 days of storage and analysed for potassium, sodium, uric acid, albumin and whole blood haemoglobin. One unit increase in baseline (0 day) potassium in extracellular fluid of blood units was associated with the following increases in potassium levels on later days of storage: around two unit increase at 1 week (r2 = 0·50, P < 0·01) of storage; four units increase at 2 weeks (r2 = 0·64, P < 0·001) and 3 weeks (r2 = 0·51, P < 0·01) of storage; six units at 4 weeks (r2 = 0·53, P < 0·01) of storage. Baseline whole blood haemoglobin showed a moderate association with baseline potassium (r2 = 0·36, P < 0·05) and 2-week potassium (r2 = 0·35, P < 0·05) values. For CPDA-1 blood bags (i) low baseline potassium blood bags might be preferred for transfusion in cases demanding a low potassium load and (ii) coordinating the ‘first-in-first-out’ (FIFO) policy with ‘early release of blood-bags with high initial potassium’ might be helpful in improving the release of suitable blood units from blood-banks.
Vongsakulyanon, A; Kitpoka, P; Kunakorn, M; Srikhirin, T
2015-12-01
To develop reliable and convenient methods for Miltenberger (Mi(a) ) blood group typing. To apply real-time polymerase chain reaction (qPCR) melting curve analysis to Mi(a) blood group typing. The Mi(a) blood group is the collective set of glycophorin hybrids in the MNS blood group system. Mi(a+) blood is common among East Asians and is also found in the Thai population. Incompatible Mi(a) blood transfusions pose the risk of life-threatening haemolysis; therefore, Mi(a) blood group typing is necessary in ethnicities where the Mi(a) blood group is prevalent. One hundred and forty-three blood samples from Thai blood donors were used in the study. The samples included 50 Mi(a+) samples and 93 Mi(a-) samples, which were defined by serology. The samples were typed by Mi(a) typing qPCR, and 50 Mi(a+) samples were sequenced to identify the Mi(a) subtypes. Mi(a) subtyping qPCR was performed to define GP.Mur. Both Mi(a) typing and Mi(a) subtyping were tested on a conventional PCR platform. The results of Mi(a) typing qPCR were all concordant with serology. Sequencing of the 50 Mi(a+) samples revealed 47 GP.Mur samples and 3 GP.Hop or Bun samples. Mi(a) subtyping qPCR was the supplementary test used to further define GP.Mur from other Mi(a) subtypes. Both Mi(a) typing and Mi(a) subtyping performed well using a conventional PCR platform. Mi(a) typing qPCR correctly identified Mi(a) blood groups in a Thai population with the feasibility of Mi(a) subtype discrimination, and Mi(a) subtyping qPCR was able to further define GP.Mur from other Mi(a) subtypes. © 2015 British Blood Transfusion Society.
Van Looy, Stijn; Verplancke, Thierry; Benoit, Dominique; Hoste, Eric; Van Maele, Georges; De Turck, Filip; Decruyenaere, Johan
2007-01-01
Tacrolimus is an important immunosuppressive drug for organ transplantation patients. It has a narrow therapeutic range, toxic side effects, and a blood concentration with wide intra- and interindividual variability. Hence, it is of the utmost importance to monitor tacrolimus blood concentration, thereby ensuring clinical effect and avoiding toxic side effects. Prediction models for tacrolimus blood concentration can improve clinical care by optimizing monitoring of these concentrations, especially in the initial phase after transplantation during intensive care unit (ICU) stay. This is the first study in the ICU in which support vector machines, as a new data modeling technique, are investigated and tested in their prediction capabilities of tacrolimus blood concentration. Linear support vector regression (SVR) and nonlinear radial basis function (RBF) SVR are compared with multiple linear regression (MLR). Tacrolimus blood concentrations, together with 35 other relevant variables from 50 liver transplantation patients, were extracted from our ICU database. This resulted in a dataset of 457 blood samples, on average between 9 and 10 samples per patient, finally resulting in a database of more than 16,000 data values. Nonlinear RBF SVR, linear SVR, and MLR were performed after selection of clinically relevant input variables and model parameters. Differences between observed and predicted tacrolimus blood concentrations were calculated. Prediction accuracy of the three methods was compared after fivefold cross-validation (Friedman test and Wilcoxon signed rank analysis). Linear SVR and nonlinear RBF SVR had mean absolute differences between observed and predicted tacrolimus blood concentrations of 2.31 ng/ml (standard deviation [SD] 2.47) and 2.38 ng/ml (SD 2.49), respectively. MLR had a mean absolute difference of 2.73 ng/ml (SD 3.79). The difference between linear SVR and MLR was statistically significant (p < 0.001). RBF SVR had the advantage of requiring only 2 input variables to perform this prediction in comparison to 15 and 16 variables needed by linear SVR and MLR, respectively. This is an indication of the superior prediction capability of nonlinear SVR. Prediction of tacrolimus blood concentration with linear and nonlinear SVR was excellent, and accuracy was superior in comparison with an MLR model.
Pathologists and liquid biopsies: to be or not to be?
Hofman, Paul; Popper, Helmut H
2016-12-01
Recently, the advent of therapies targeting genomic alterations has improved the care of patients with certain types of cancer. While molecular targets were initially detected in nucleic acid samples extracted from tumor tissue, detection of nucleic acids in circulating blood has allowed the development of what has become known as liquid biopsies, which provide a complementary and alternative sample source allowing identification of genomic alterations that might be addressed by targeted therapy. Consequently, liquid biopsies might rapidly revolutionize oncology practice in allowing administration of more effective treatments. Liquid biopsies also provide an approach towards short-term monitoring of metastatic cancer patients to evaluate efficacy of treatment and/or early detection of secondary mutations responsible for resistance to treatment. In this context, pathologists, who have already been required in recent years to take interest in the domain of molecular pathology of cancer, now face new challenges. The attitude of pathologists to and level of involvement in the practice of liquid biopsies, including mastering the methods employed in molecular analysis of blood samples, need close attention. Regardless of the level of involvement of pathologists in this new field, it is mandatory that oncologists, biologists, geneticists, and pathologists work together to coordinate the pre-analytical, analytical, and post-analytical phases of molecular assessment of tissue and liquid samples of individual cancer patients. The challenges include (1) implementation of effective and efficient procedures for reception and analysis of liquid and tissue samples for histopathological and molecular evaluation and (2) assuring short turn-around times to facilitate rapid optimization of individual patient treatment. In this paper, we will review the following: (1) recent data concerning the concept of liquid biopsies in oncology and its development for patient care, (2) advantages and limitations of molecular analyses performed on blood samples compared to those performed on tissue samples, and (3) short-term challenges facing pathologists in dealing with liquid biopsies of cancer patients and new strategies to early detect metastatic tumor cell clones.
Isohashi, Kayako; Shimosegawa, Eku; Naka, Sadahiro; Kanai, Yasukazu; Horitsugi, Genki; Mochida, Ikuko; Matsunaga, Keiko; Watabe, Tadashi; Kato, Hiroki; Tatsumi, Mitsuaki; Hatazawa, Jun
2016-12-01
In boron neutron capture therapy (BNCT), positron emission tomography (PET) with 4-borono-2- 18 F-fluoro-phenylalanine (FBPA) is the only method to estimate an accumulation of 10 B to target tumor and surrounding normal tissue after administering 10 B carrier of L-paraboronophenylalanine and to search the indication of BNCT for individual patient. Absolute concentration of 10 B in tumor has been estimated by multiplying 10 B concentration in blood during BNCT by tumor to blood radioactivity (T/B) ratio derived from FBPA PET. However, the method to measure blood radioactivity either by blood sampling or image data has not been standardized. We compared image-derived blood radioactivity of FBPA with blood sampling data and studied appropriate timing and location for measuring image-derived blood counts. We obtained 7 repeated whole-body PET scans in five healthy subjects. Arterialized venous blood samples were obtained from the antecubital vein, heated in a heating blanket. Time-activity curves (TACs) of image-derived blood radioactivity were obtained using volumes of interest (VOIs) over ascending aorta, aortic arch, pulmonary artery, left and right ventricles, inferior vena cava, and abdominal aorta. Image-derived blood radioactivity was compared with those measured by blood sampling data in each location. Both the TACs of blood sampling radioactivity in each subject, and the TACs of image-derived blood radioactivity showed a peak within 5 min after the tracer injection, and promptly decreased soon thereafter. Linear relationship was found between blood sampling radioactivity and image-derived blood radioactivity in all the VOIs at any timing of data sampling (p < 0.001). Image-derived radioactivity measured in the left and right ventricles 30 min after injection showed high correlation with blood radioactivity. Image-derived blood radioactivity was lower than blood sampling radioactivity data by 20 %. Reduction of blood radioactivity of FBPA in left ventricle after 30 min of FBPA injection was minimal. We conclude that the image-derived T/B ratio can be reliably used by setting the VOI on the left ventricle at 30 min after FBPA administration and correcting for underestimation due to partial volume effect and reduction of FBPA blood radioactivity.
Tissue reservoirs of antiviral T cell immunity in persistent human CMV infection
Gordon, Claire L.; Thome, Joseph J.C.; Igarashi, Suzu
2017-01-01
T cell responses to viruses are initiated and maintained in tissue sites; however, knowledge of human antiviral T cells is largely derived from blood. Cytomegalovirus (CMV) persists in most humans, requires T cell immunity to control, yet tissue immune responses remain undefined. Here, we investigated human CMV-specific T cells, virus persistence and CMV-associated T cell homeostasis in blood, lymphoid, mucosal and secretory tissues of 44 CMV seropositive and 28 seronegative donors. CMV-specific T cells were maintained in distinct distribution patterns, highest in blood, bone marrow (BM), or lymph nodes (LN), with the frequency and function in blood distinct from tissues. CMV genomes were detected predominantly in lung and also in spleen, BM, blood and LN. High frequencies of activated CMV-specific T cells were found in blood and BM samples with low virus detection, whereas in lung, CMV-specific T cells were present along with detectable virus. In LNs, CMV-specific T cells exhibited quiescent phenotypes independent of virus. Overall, T cell differentiation was enhanced in sites of viral persistence with age. Together, our results suggest tissue T cell reservoirs for CMV control shaped by both viral and tissue-intrinsic factors, with global effects on homeostasis of tissue T cells over the lifespan. PMID:28130404
Tissue reservoirs of antiviral T cell immunity in persistent human CMV infection.
Gordon, Claire L; Miron, Michelle; Thome, Joseph J C; Matsuoka, Nobuhide; Weiner, Joshua; Rak, Michael A; Igarashi, Suzu; Granot, Tomer; Lerner, Harvey; Goodrum, Felicia; Farber, Donna L
2017-03-06
T cell responses to viruses are initiated and maintained in tissue sites; however, knowledge of human antiviral T cells is largely derived from blood. Cytomegalovirus (CMV) persists in most humans, requires T cell immunity to control, yet tissue immune responses remain undefined. Here, we investigated human CMV-specific T cells, virus persistence and CMV-associated T cell homeostasis in blood, lymphoid, mucosal and secretory tissues of 44 CMV seropositive and 28 seronegative donors. CMV-specific T cells were maintained in distinct distribution patterns, highest in blood, bone marrow (BM), or lymph nodes (LN), with the frequency and function in blood distinct from tissues. CMV genomes were detected predominantly in lung and also in spleen, BM, blood and LN. High frequencies of activated CMV-specific T cells were found in blood and BM samples with low virus detection, whereas in lung, CMV-specific T cells were present along with detectable virus. In LNs, CMV-specific T cells exhibited quiescent phenotypes independent of virus. Overall, T cell differentiation was enhanced in sites of viral persistence with age. Together, our results suggest tissue T cell reservoirs for CMV control shaped by both viral and tissue-intrinsic factors, with global effects on homeostasis of tissue T cells over the lifespan. @Gordon et al.
Leukocyte and platelet depletion improves blood flow and function in a renal transplant model.
Yates, Phillip J; Hosgood, Sarah A; Nicholson, Michael L
2012-01-01
Donation after cardiac death (DCD) donors are an important source of organs for transplantation. Due to warm and cold ischemic injury, DCD kidneys undergo a significant reperfusion insult when transplanted. This is manifested clinically as a high incidence of delayed graft function (DGF) and primary non-function (PNF). The importance of leukocytes in the generation of reperfusion injury is pivotal. Using an ex vivo porcine model of kidney transplantation, the effects of reperfusion with leukocyte and platelet depleted blood (LDB) and whole blood (WB) on renal blood flow and function were compared. Hemodynamic measurements were recorded, and biochemical, hematological, and histologic samples taken at set time-points. Reperfusion with LDB improved renal blood flow significantly compared with WB reperfusion. In addition, there was a significant improvement in creatinine clearance and renal oxygen consumption, but not fractional excretion of sodium, acid-base homeostasis, urinary nitric oxide (NO), or 8-isoprostane levels. This study represents a good model for the initial reperfusion period in renal transplantation. Improvement in only some functional markers and neither urinary NO nor 8-isoprostane levels indicates that improved blood flow alone is not sufficient to reverse the severe ischemic insult endured by DCD kidneys. Copyright © 2012 Elsevier Inc. All rights reserved.
Kaplan, H S
2005-11-01
Safety and reliability in blood transfusion are not static, but are dynamic non-events. Since performance deviations continually occur in complex systems, their detection and correction must be accomplished over and over again. Non-conformance must be detected early enough to allow for recovery or mitigation. Near-miss events afford early detection of possible system weaknesses and provide an early chance at correction. National event reporting systems, both voluntary and involuntary, have begun to include near-miss reporting in their classification schemes, raising awareness for their detection. MERS-TM is a voluntary safety reporting initiative in transfusion. Currently 22 hospitals submit reports anonymously to a central database which supports analysis of a hospital's own data and that of an aggregate database. The system encourages reporting of near-miss events, where the patient is protected from receiving an unsuitable or incorrect blood component due to a planned or unplanned recovery step. MERS-TM data suggest approximately 90% of events are near-misses, with 10% caught after issue but before transfusion. Near-miss reporting may increase total reports ten-fold. The ratio of near-misses to events with harm is 339:1, consistent with other industries' ratio of 300:1, which has been proposed as a measure of reporting in event reporting systems. Use of a risk matrix and an event's relation to protective barriers allow prioritization of these events. Near-misses recovered by planned barriers occur ten times more frequently then unplanned recoveries. A bedside check of the patient's identity with that on the blood component is an essential, final barrier. How the typical two person check is performed, is critical. Even properly done, this check is ineffective against sampling and testing errors. Blood testing at bedside just prior to transfusion minimizes the risk of such upstream events. However, even with simple and well designed devices, training may be a critical issue. Sample errors account for more than half of reported events. The most dangerous miscollection is a blood sample passing acceptance with no previous patient results for comparison. Bar code labels or collection of a second sample may counter this upstream vulnerability. Further upstream barriers have been proposed to counter the precariousness of urgent blood sample collection in a changing unstable situation. One, a linking device, allows safer labeling of tubes away from the bedside, the second, a forcing function, prevents omission of critical patient identification steps. Errors in the blood bank itself account for 15% of errors with a high potential severity. In one such event, a component incorrectly issued, but safely detected prior to transfusion, focused attention on multitasking's contribution to laboratory error. In sum, use of near-miss information, by enhancing barriers supporting error prevention and mitigation, increases our capacity to get the right blood to the right patient.
Thomson, Jessica L.; Landry, Alicia S.; Anderson-Lewis, Charkarra; Connell, Carol; Molaison, Elaine Fontenot; Yadrick, Kathleen
2014-01-01
Introduction Effective strategies are needed to reach and treat people who lack awareness of or have uncontrolled hypertension. We used data from a community-based participatory research initiative, Hub City Steps, to quantify the prevalence of undiagnosed hypertension and determine the relationship between hypertension status at baseline and postintervention improvements in blood pressure and health-related quality of life. Methods Hub City Steps was a 6-month preintervention–postintervention lifestyle intervention targeting hypertension risk factors. Outcome measures were collected at baseline, 3 months, and 6 months. Generalized linear mixed models were used to test for effects by time and hypertension status. Results Of the enrolled sample (N = 269), most were overweight or obese (91%), African American (94%), and women (85%). When considering hypertension status, 42% had self-reported diagnosis of hypertension (self-reported subgroup; 84% with antihypertensive medication use); 36% had no self-reported medical history of hypertension, but when blood pressure was measured they had a clinical diagnosis of prehypertension or hypertension (undiagnosed subgroup); and 22% had no self-reported or clinical hypertension diagnosis (no hypertension subgroup). From baseline to 6 months, systolic blood pressure significantly improved for participants with self-reported hypertension [8.2 (SD, 18.2) mm Hg] and undiagnosed hypertension [12.3 (SD, 16.3) mm Hg], with undiagnosed participants experiencing the greatest improvements (P < .001). Effects remained significant after controlling for covariates. Health-related quality of life significantly improved for all 3 hypertension subgroups, with no apparent subgroup differences. Conclusion This study reveals advantages of a culturally appropriate community-based participatory research initiative to reach those with undetected hypertension and effectively improve blood pressure status and health-related quality of life. PMID:24698531
Anemia in the preterm infant: Erythropoietin versus erythrocyte transfusion — It’s not that simple
Von Kohorn, Isabelle; Ehrenkranz, Richard A.
2009-01-01
SYNOPSIS Since the late 1980s recombinant human erythropoietin (r-Epo) has been studied as an alternative to packed red blood cell (RBC) transfusion for the treatment of anemia of prematurity in very low birth weight (VLBW, <1500 grams) infants. Initial trials and reports focused on r-Epo’s ability to prevent or treat anemia of prematurity with the goal of eliminating RBC transfusion, but achieved limited success. Reduced volumes of blood sampling for laboratory tests and improved blood banking techniques have decreased the need for RBC transfusion. New concerns about the safety of r-Epo administration have emerged. Past cost-benefit analyses of r-Epo administration versus transfusion for the treatment of anemia of prematurity have been nearly balanced. Autologous transfusion, blood-sparing technologies, changes in RBC transfusion technique and safety, and further elucidation of the risk-benefit ratio of r-Epo therapy may change the cost-benefit analysis. The jury is still out with regard to the role of r-Epo therapy in the VLBW population. PMID:19161869
Human babesiosis in Southeast China: A case report.
Huang, Shanshan; Zhang, Lingling; Yao, Linong; Li, Jie; Chen, Hui; Ni, Qingxiang; Pan, Chenwei; Jin, Lingxiang
2018-03-01
A 60-year-old female patient living in Southeast China presented with persistent fever, chills, night sweats, fatigue, and dizziness of 12-day duration. Blood tests showed neutropenia, thrombocytopenia, and active hemolytic anemia, with elevated C-reactive protein. Broad-spectrum antibiotics were administered for a possible diagnosis of sepsis, without any response. Malaria was initially diagnosed after visualizing intraerythrocytic ring-shaped parasites in bone marrow and blood smears. The patient resided in an area of unstable endemicity for Plasmodium falciparum. Blood samples were sent to the Centers for Disease Control and Prevention and a definitive diagnosis of human babesiosis was made using Babesia microti-specific PCR. Chloroquine phosphate and clindamycin were started and the patient became normothermic. However, due to the intolerable adverse effects of the antibiotics, intravenous azithromycin was given as an alternative. The patient recovered from fever and hemolysis, and repeated peripheral blood smears showed hemoparasite clearance. Cases of human babesiosis are rarely reported and probably under-diagnosed in China; therefore, improving our understanding of this disease as a newly emerging public health threat is imperative. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.
NASA Technical Reports Server (NTRS)
Alfrey, Clarence P.
1995-01-01
The purpose of this contract was to design and conduct experiments that would increase our understanding of the influence of space flight on erythrokinetics and the rapid change that occurs in the red blood cell mass during spaceflight. The experiment designated E261, was flown on Space Life Science missions SLS-1 and SLS-2 (STS 40 and STS 58). Unique features of this experiment included radionuclide tracer studies during flight and frequent in-flight blood samples specifically for the first three or four days of the mission. Plasma volume measurements were made early and late in the missions. Radioactive iron kinetics studies were initiated after one or three days in microgravity since the magnitude of the red blood cell mass decrease dictated that bone marrow production must be decreased very early in the flight. The schedule was designed to study the time course of the changes that occur during spaceflight and to possibly define a mechanism for the rapid reduction in red blood cell mass.
Freiser, Helene; Manganais, Christopher; Santerre, Charles R.
2015-01-01
Fish has many health benefits but is also the most common source of methylmercury. The bioavailability of methylmercury in fish may be affected by other meal components. In this study, the effect of green tea on the bioavailability of methylmercury from an oral bolus of fish muscle tissue was studied in rats and compared to a water treated control group and a group treated with meso-2,3-dimercaptosuccinic acid (DMSA), a compound used medically to chelate mercury. Rats were given a single oral dose of fish tissue via gavage and one of the treatments. Rats were given access to food for 3 h at 12 h intervals. They were dosed with each of the treatments with each meal. Blood samples were collected for 95 hours. Green tea significantly increased the concentration of total mercury in blood relative to the control, whereas DMSA significantly decreased it. In addition, feeding caused a slight increase in blood mercury for several meals following the initial dose. PMID:26301246
Case report of unexplained hypocalcaemia in a slightly haemolysed sample.
Cornes, Michael
2017-06-15
The case presented highlights a common pre-analytical problem identified in the laboratory that was initially missed. It concerns a young, generally healthy adult patient with no significant medical history and no significant family history. They presented with common flu like symptoms to their primary care clinician who considered this was most likely a viral problem that would pass with time. The clinician, however, did some routine bloods to reassure the patient despite a lack of clinical indication. When the sample was analysed the sample was haemolysed with strikingly low calcium. This led to the patient being called into hospital for urgent repeat investigations, all of which turned out to be within normal ranges. On further investigation the original sample was found to be contaminated. This result would normally have been flagged but was missed due to the complication of haemolysis.
Raab, Jennifer; Haupt, Florian; Scholz, Marlon; Matzke, Claudia; Warncke, Katharina; Lange, Karin; Assfalg, Robin; Weininger, Katharina; Wittich, Susanne; Löbner, Stephanie; Beyerlein, Andreas; Nennstiel-Ratzel, Uta; Lang, Martin; Laub, Otto; Dunstheimer, Desiree; Bonifacio, Ezio; Achenbach, Peter; Winkler, Christiane; Ziegler, Anette-G
2016-01-01
Introduction Type 1 diabetes can be diagnosed at an early presymptomatic stage by the detection of islet autoantibodies. The Fr1da study aims to assess whether early staging of type 1 diabetes (1) is feasible at a population-based level, (2) prevents severe metabolic decompensation observed at the clinical manifestation of type 1 diabetes and (3) reduces psychological distress through preventive teaching and care. Methods and analysis Children aged 2–5 years in Bavaria, Germany, will be tested for the presence of multiple islet autoantibodies. Between February 2015 and December 2016, 100 000 children will be screened by primary care paediatricians. Islet autoantibodies are measured in capillary blood samples using a multiplex three-screen ELISA. Samples with ELISA results >97.5th centile are retested using reference radiobinding assays. A venous blood sample is also obtained to confirm the autoantibody status of children with at least two autoantibodies. Children with confirmed multiple islet autoantibodies are diagnosed with pre-type 1 diabetes. These children and their parents are invited to participate in an education and counselling programme at a local diabetes centre. Depression and anxiety, and burden of early diagnosis are also assessed. Results Of the 1027 Bavarian paediatricians, 39.3% are participating in the study. Overall, 26 760 children have been screened between February 2015 and November 2015. Capillary blood collection was sufficient in volume for islet autoantibody detection in 99.46% of the children. The remaining 0.54% had insufficient blood volume collected. Of the 26 760 capillary samples tested, 0.39% were positive for at least two islet autoantibodies. Discussion Staging for early type 1 diabetes within a public health setting appears to be feasible. The study may set new standards for the early diagnosis of type 1 diabetes and education. Ethics dissemination The study was approved by the ethics committee of Technische Universität München (Nr. 70/14). PMID:27194320
Raab, Jennifer; Haupt, Florian; Scholz, Marlon; Matzke, Claudia; Warncke, Katharina; Lange, Karin; Assfalg, Robin; Weininger, Katharina; Wittich, Susanne; Löbner, Stephanie; Beyerlein, Andreas; Nennstiel-Ratzel, Uta; Lang, Martin; Laub, Otto; Dunstheimer, Desiree; Bonifacio, Ezio; Achenbach, Peter; Winkler, Christiane; Ziegler, Anette-G
2016-05-18
Type 1 diabetes can be diagnosed at an early presymptomatic stage by the detection of islet autoantibodies. The Fr1da study aims to assess whether early staging of type 1 diabetes (1) is feasible at a population-based level, (2) prevents severe metabolic decompensation observed at the clinical manifestation of type 1 diabetes and (3) reduces psychological distress through preventive teaching and care. Children aged 2-5 years in Bavaria, Germany, will be tested for the presence of multiple islet autoantibodies. Between February 2015 and December 2016, 100 000 children will be screened by primary care paediatricians. Islet autoantibodies are measured in capillary blood samples using a multiplex three-screen ELISA. Samples with ELISA results >97.5th centile are retested using reference radiobinding assays. A venous blood sample is also obtained to confirm the autoantibody status of children with at least two autoantibodies. Children with confirmed multiple islet autoantibodies are diagnosed with pre-type 1 diabetes. These children and their parents are invited to participate in an education and counselling programme at a local diabetes centre. Depression and anxiety, and burden of early diagnosis are also assessed. Of the 1027 Bavarian paediatricians, 39.3% are participating in the study. Overall, 26 760 children have been screened between February 2015 and November 2015. Capillary blood collection was sufficient in volume for islet autoantibody detection in 99.46% of the children. The remaining 0.54% had insufficient blood volume collected. Of the 26 760 capillary samples tested, 0.39% were positive for at least two islet autoantibodies. Staging for early type 1 diabetes within a public health setting appears to be feasible. The study may set new standards for the early diagnosis of type 1 diabetes and education. The study was approved by the ethics committee of Technische Universität München (Nr. 70/14). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Development of a microfluidic device for cell concentration and blood cell-plasma separation.
Maria, M Sneha; Kumar, B S; Chandra, T S; Sen, A K
2015-12-01
This work presents design, fabrication and test of a microfluidic device which employs Fahraeus-Lindqvist and Zweifach-Fung effects for cell concentration and blood cell-plasma separation. The device design comprises a straight main channel with a series of branched channels placed symmetrically on both sides of the main channel. The design implements constrictions before each junction (branching point) in order to direct cells that would have migrated closer to the wall (naturally or after liquid extraction at a junction) towards the centre of the main channel. Theoretical and numerical analysis are performed for design of the microchannel network to ensure that a minimum flow rate ratio (of 2.5:1, main channel-to-side channels) is maintained at each junction and predict flow rate at the plasma outlet. The dimensions and location of the constrictions were determined using numerical simulations. The effect of presence of constrictions before the junctions was demonstrated by comparing the performances of the device with and without constrictions. To demonstrate the performance of the device, initial experiments were performed with polystyrene microbeads (10 and 15 μm size) and droplets. Finally, the device was used for concentration of HL60 cells and separation of plasma and cells in diluted blood samples. The cell concentration and blood-plasma purification efficiency was quantified using Haemocytometer and Fluorescence-Activated Cell Sorter (FACS). A seven-fold cell concentration was obtained with HL60 cells and a purification efficiency of 70 % and plasma recovery of 80 % was observed for diluted (1:20) blood sample. FACS was used to identify cell lysis and the cell viability was checked using Trypan Blue test which showed that more than 99 % cells are alive indicating the suitability of the device for practical use. The proposed device has potential to be used as a sample preparation module in lab on chip based diagnostic platforms.
NASA Astrophysics Data System (ADS)
Bitner, Rex M.; Koller, Susan C.
2002-06-01
The automated high throughput purification of genomic DNA form plant materials can be performed using MagneSil paramagnetic particles on the Beckman-Coulter FX, BioMek 2000, and the Tecan Genesis robot. Similar automated methods are available for DNA purifications from animal blood. These methods eliminate organic extractions, lengthy incubations and cumbersome filter plates. The DNA is suitable for applications such as PCR and RAPD analysis. Methods are described for processing traditionally difficult samples such as those containing large amounts of polyphenolics or oils, while still maintaining a high level of DNA purity. The robotic protocols have ben optimized for agricultural applications such as marker assisted breeding, seed-quality testing, and SNP discovery and scoring. In addition to high yield purification of DNA from plant samples or animal blood, the use of Promega's DNA-IQ purification system is also described. This method allows for the purification of a narrow range of DNA regardless of the amount of additional DNA that is present in the initial sample. This simultaneous Isolation and Quantification of DNA allows the DNA to be used directly in applications such as PCR, SNP analysis, and RAPD, without the need for separate quantitation of the DNA.
Spectral feature characterization methods for blood stain detection in crime scene backgrounds
NASA Astrophysics Data System (ADS)
Yang, Jie; Mathew, Jobin J.; Dube, Roger R.; Messinger, David W.
2016-05-01
Blood stains are one of the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Blood spectral signatures containing unique reflectance or absorption features are important both for forensic on-site investigation and laboratory testing. They can be used for target detection and identification applied to crime scene hyperspectral imagery, and also be utilized to analyze the spectral variation of blood on various backgrounds. Non-blood stains often mislead the detection and can generate false alarms at a real crime scene, especially for dark and red backgrounds. This paper measured the reflectance of liquid blood and 9 kinds of non-blood samples in the range of 350 nm - 2500 nm in various crime scene backgrounds, such as pure samples contained in petri dish with various thicknesses, mixed samples with different colors and materials of fabrics, and mixed samples with wood, all of which are examined to provide sub-visual evidence for detecting and recognizing blood from non-blood samples in a realistic crime scene. The spectral difference between blood and non-blood samples are examined and spectral features such as "peaks" and "depths" of reflectance are selected. Two blood stain detection methods are proposed in this paper. The first method uses index to denote the ratio of "depth" minus "peak" over"depth" add"peak" within a wavelength range of the reflectance spectrum. The second method uses relative band depth of the selected wavelength ranges of the reflectance spectrum. Results show that the index method is able to discriminate blood from non-blood samples in most tested crime scene backgrounds, but is not able to detect it from black felt. Whereas the relative band depth method is able to discriminate blood from non-blood samples on all of the tested background material types and colors.
Effect of Haemoproteus columbae infection on the hemogram of the Pigeons (Columba livia domestica).
Samani, Amir Dehghani; Kheirabadi, Khodadad Pirali; Mohebbi, Abdonnaser
2016-12-01
It has been reported that parasites affect the health and productivity of birds, initiate excessive preening which interrupts feeding, as the birds spend much time preening rather than being involved in other essential life activities. Haemoproteus columbae occurs in pigeons widely in tropical and subtropical regions. The present investigation was concentrated on the effect of H. columbae infection on the hemogram and changes in the number of white blood cells in infected pigeons. Blood samples taked from 100 pigeons in Shahrekord. Blood smears stained and observed for H. columbae infection. Packed cell volume (PCV) and total white blood cells (WBC) count and differential WBC count determinate for every smears. This study show that PCV increased in infected pigeons by H. columbae than non infected pigeons. There were increasing in the number of total WBC in the infected pigeons by H. columbae than non infected pigeons. Also there were significant differences between the number of lymphocytes and eosinophils in the infected pigeons by H. columbae than non infected pigeons. This study and same studies show the part of the effects of blood parasites on the hemogram, but there were many questions about the effects of blood parasites such as H. columbae on the other parameters of host's blood, so we advise to focus on the other hematological parameters in the future studies.
Wei, Bo; Chen, Lei; Kibukawa, Miho; Kang, John; Waskin, Hetty; Marton, Matthew
2016-12-01
Chagas disease is caused by the parasitic infection of Trypanosoma cruzi (T. cruzi). The STOP CHAGAS clinical trial was initiated in 2011 to evaluate posaconazole in treating Chagas disease, with treatment success defined as negative qualitative PCR results of detecting the parasites in blood specimens collected post-treatment. PAXgene Blood DNA tubes were utilized as a simple procedure to collect and process blood specimens. However, the PAXgene blood specimens challenged published T. cruzi PCR methods, resulting in poor sensitivity and reproducibility. To accurately evaluate the treatment efficacy of the clinical study, we developed and validated a robust PCR assay for detecting low level T. cruzi in PAXgene blood specimens. The assay combines a new DNA extraction method with a custom designed qPCR assay, resulting in limit of detection of 0.005 and 0.01 fg/μl for K98 and CL Brener, two representative strains of two of T. cruzi's discrete typing units. Reliable qPCR standard curves were established for both strains to measure parasite loads, with amplification efficiency ≥ 90% and the lower limit of linearity ≥ 0.05 fg/μl. The assay successfully analyzed the samples collected from the STOP CHAGAS study and may prove useful for future global clinical trials evaluating new therapies for asymptomatic chronic Chagas disease.
Blood and exhaled air can be used for biomonitoring of hydrofluorocarbon exposure.
Ernstgård, Lena; Sjögren, Bengt; Gunnare, Sara; Johanson, Gunnar
2014-02-10
Various hydrofluorocarbons (HFCs) have replaced the ozone-depleting chlorofluorocarbons and hydrochlorofluorocarbons during the last decades. The objective of this study was to examine the usefulness of blood and breath for exposure biomonitoring of HFCs. We compared data on blood and exhaled air from a series of experiments where healthy volunteers were exposed to vapors of four commonly used HFCs; 1,1-difluoroethane, 1,1,1-trifluoroethane, 1,1,1,2-tetrafluoroethane, and 1,1,1,3,3-pentafluoropropane. All four HFCs had similar toxicokinetic profiles in blood with a rapid initial increase and an apparent steady-state reached within a few minutes. For all HFCs, the inhalation uptake during exposure was low (less than 6%), most of which was exhaled post-exposure. No metabolism could be detected and only minor amounts were excreted unchanged in urine. The observed time courses in blood and breath were well described by physiologically-based pharmacokinetic (PBPK) modeling. Simulations of 8-h exposures show that the HFC levels in both blood and breath drop rapidly during the first minutes post-exposure, whereafter the decline is considerably slower and mainly reflects washout from fat tissues. We conclude that blood and exhaled air can be used for biological exposure monitoring. Samples should not be taken immediately at the end of shift but rather 20-30 min later. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Sewage sludge does not induce genotoxicity and carcinogenesis.
Silva, Paula Regina Pereira; Barbisan, Luis Fernando; Dagli, Maria Lúcia Zaidan; Saldiva, Paulo Hilário Nascimento
2012-07-01
Through a series of experiments, the genotoxic/mutagenic and carcinogenic potential of sewage sludge was assessed. Male Wistar rats were randomly assigned to four groups: Group 1 - negative control; Group 2 - liver carcinogenesis initiated by diethylnitrosamine (DEN; 200 mg/kg i.p.); Group 3 and G4-liver carcinogenesis initiated by DEN and fed 10,000 ppm or 50,000 ppm of sewage sludge. The animals were submitted to a 70% partial hepatectomy at the 3(rd) week. Livers were processed for routine histological analysis and immunohistochemistry, in order to detect glutathione S-transferase positive altered hepatocyte foci (GST-P(+) AHF). Peripheral blood samples for the comet assay were obtained from the periorbital plexus immediately prior to sacrificing. Polychromatic erythrocytes (PCEs) were analyzed in femoral bone-marrow smears, and the frequencies of those micronucleated (MNPCEs) registered. There was no sewage-sludge-induced increase in frequency of either DNA damage in peripheral blood leucocytes, or MNPCEs in the femoral bone marrow. Also, there was no increase in the levels of DNA damage, in the frequency of MNPCEs, and in the development of GST-P AHF when compared with the respective control group.
Plasmodium ovale infection in Malaysia: first imported case.
Lim, Yvonne A L; Mahmud, Rohela; Chew, Ching Hoong; T, Thiruventhiran; Chua, Kek Heng
2010-10-08
Plasmodium ovale infection is rarely reported in Malaysia. This is the first imported case of P. ovale infection in Malaysia which was initially misdiagnosed as Plasmodium vivax. Peripheral blood sample was first examined by Giemsa-stained microscopy examination and further confirmed using a patented in-house multiplex PCR followed by sequencing. Initial results from peripheral blood smear examination diagnosed P. vivax infection. However further analysis using a patented in-house multiplex PCR followed by sequencing confirmed the presence of P. ovale. Given that Anopheles maculatus and Anopheles dirus, vectors of P. ovale are found in Malaysia, this finding has significant implication on Malaysia's public health sector. The current finding should serve as an alert to epidemiologists, clinicians and laboratory technicians in the possibility of finding P. ovale in Malaysia. P. ovale should be considered in the differential diagnosis of imported malaria cases in Malaysia due to the exponential increase in the number of visitors from P. ovale endemic regions and the long latent period of P. ovale. It is also timely that conventional diagnosis of malaria via microscopy should be coupled with more advanced molecular tools for effective diagnosis.
Bewig, B; Haacke, T C; Tiroke, A; Bastian, A; Böttcher, H; Hirt, S W; Rautenberg, P; Haverich, A
2000-01-01
Cytomegalovirus (CMV) is known as a common pathogen causing infections after lung transplantation. Rapid diagnosis of CMV infection is important for the initiation of a specific treatment. Evaluation of methods for the rapid diagnosis of CMV pneumonitis. The detection rates of CMV DNA in bronchoalveolar lavage (BAL) and bronchial brushes by polymerase chain reaction (PCR), of viral antigens (p52 and IE1) in BAL and of pp65 antigen in peripheral blood leukocytes were compared to the clinical status after lung transplantation. In 28 patients, 105 BAL, 96 blood samples and 14 brushes were analyzed. In 6 patients, a total of eight episodes of CMV pneumonitis occurred. Five of the 6 with positive CMV antigens in BAL (p52 or IE1) showed signs of CMV pneumonitis. All episodes of CMV pneumonitis were detected by the PCR of BAL cells. Fourteen samples positive for CMV pp65 antigen in blood were negative in BAL PCR. In these cases, no clinical signs of pulmonary CMV infection occurred. Overall sensitivity, specificity, and positive and negative predictive values for the detection of CMV pneumonitis by PCR of BAL cells were 100, 98.9, 88.9 and 100%, respectively. In brush samples, PCR did not provide additional information to the results of the PCR of BAL cells. PCR of DNA from BAL cells is suitable for reliable and rapid detection of CMV pneumonitis. Copyright 2000 S. Karger AG, Basel.
Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros
Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N.; Payne, Junaidi
2013-01-01
Objective To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Methods Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA® blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. Results BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. Conclusions This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases. PMID:23593586
Arslan, Zainab; Athiraman, Naveen K; Clark, Simon J
2016-08-01
Lithium toxicity in a neonate can occur owing to antenatal exposure as a result of maternal treatment for psychiatric illnesses. False elevation of lithium levels has been reported in the paediatric population when the sample was mistakenly collected in a lithium heparin container. A term, male infant was born to a mother who was on lithium treatment for a psychiatric illness. On day 1, the infant was jittery, had a poor suck with difficulties in establishing feeds. Blood taken from the infant approximately 8 hours after birth demonstrated a lithium level of 4.9 mmol/L (adult toxic level w1.5 mmol/L). However, the sample for lithium levels was sent in a lithium heparin container and the probability of false elevation was considered. He was closely monitored in the neonatal intensive care unit and his hydration was optimised with intravenous fluids. Clinically, he remained well and commenced feeding, and his jitteriness had decreased the following day. A repeat blood lithium level, collected in a gel container, was only 0.4 mmol/L. The initially raised lithium level was owing to contamination from the lithium heparin container.
Hodnett, Darragh; Wood, David M; Raja, Kishor; Dargan, Paul I; Shah, Anoop D
2012-02-01
The trace elements cobalt (Co), chromium (Cr), manganese (Mn) and nickel (Ni) are normally present at low concentrations in blood. There has been a concern that stainless steel venepuncture needles typically used for collection of blood samples may contaminate these samples, leading to the masking of deficiency states or causing potential clinical confusion as to whether an individual has a "toxic" concentration. To determine whether there is any difference between the concentrations of the trace elements obtained by different methods of blood sampling. We took blood samples using a standard venepuncture needle, a "butterfly" winged infusion needle (three consecutive samples) and a plastic intravenous cannula (three consecutive samples) from 10 healthy volunteers. We measured the concentrations of Co, Cr, Mn and Ni in the samples using Inductively Coupled Plasma Mass Spectrometry, and used analysis of variance (ANOVA) to investigate if there was any difference between the methods of blood sampling. The mean ± standard deviation blood metal concentrations were: Co 0.33 ± 0.2 μg/l, Cr 2.43 ± 1.55 μg/l, Mn 8.07 ± 7.74 μg/l and Ni 10.4 ± 4.69 μg/l. There was considerable variation between blood metal concentrations of individual subjects and a few sporadic high values. By ANOVA, there was no significant difference between the metal concentrations measured using different methods of blood collection. It is not necessary to routinely use a plastic cannula for blood sampling for trace element analysis. However, it is possible that sporadic contamination due to stainless steel needles may occur, so we would recommend that unexpected high concentrations are verified by taking a second sample taken through a plastic cannula.
Holst, Birgitte; Hau, Jann; Rozell, Björn; Abelson, Klas Stig Peter
2014-01-01
Retro-bulbar sinus puncture and facial vein phlebotomy are two widely used methods for blood sampling in laboratory mice. However, the animal welfare implications associated with these techniques are currently debated, and the possible physiological and pathological implications of blood sampling using these methods have been sparsely investigated. Therefore, this study was conducted to assess and compare the impacts of blood sampling by retro-bulbar sinus puncture and facial vein phlebotomy. Blood was obtained from either the retro-bulbar sinus or the facial vein from male C57BL/6J mice at two time points, and the samples were analyzed for plasma corticosterone. Body weights were measured at the day of blood sampling and the day after blood sampling, and the food consumption was recorded automatically during the 24 hours post-procedure. At the end of study, cheeks and orbital regions were collected for histopathological analysis to assess the degree of tissue trauma. Mice subjected to facial vein phlebotomy had significantly elevated plasma corticosterone levels at both time points in contrast to mice subjected to retro-bulbar sinus puncture, which did not. Both groups of sampled mice lost weight following blood sampling, but the body weight loss was higher in mice subjected to facial vein phlebotomy. The food consumption was not significantly different between the two groups. At gross necropsy, subcutaneous hematomas were found in both groups and the histopathological analyses revealed extensive tissue trauma after both facial vein phlebotomy and retro-bulbar sinus puncture. This study demonstrates that both blood sampling methods have a considerable impact on the animals' physiological condition, which should be considered whenever blood samples are obtained. PMID:25426941
Barker, Tyler; Rogers, Victoria E; Levy, Mark; Templeton, Jenna; Goldfine, Howard; Schneider, Erik D; Dixon, Brian M; Henriksen, Vanessa T; Weaver, Lindell K
2015-02-01
The purpose of this study was to determine if vitamin D status before supplementation influences the cytokine response after supplemental vitamin D. Forty-six reportedly healthy adults (mean(SD); age, 32(7) y; body mass index (BMI), 25.3(4.5) kg/m(2); serum 25-hydroxyvitamin D (25(OH)D), 34.8(12.2) ng/mL) were randomly assigned (double blind) to one of three groups: (1) placebo (n=15), or supplemental vitamin D (cholecalciferol) at (2) 4000 (n=14) or (3) 8000IU (n=17). Supplements were taken daily for 35days. Fasting blood samples were obtained before (Baseline, Bsl) and 35-days after (35-d) supplementation. Serum 25(OH)D, 1,25-dihydroxyvitamin D (1,25(OH)D), cytokines, and intact parathyroid hormone with calcium were measured in each blood sample. Supplemental vitamin D increased serum 25(OH)D (4000IU, ≈29%; 8000IU, ≈57%) and 1,25(OH)D (4000IU, ≈12%; 8000IU, ≈38%) without altering intact parathyroid hormone or calcium. The vitamin D metabolite increases in the supplemental vitamin D groups (n=31) were dependent on initial levels as serum 25(OH)D (r=-0.63, p<0.05) and 1,25(OH)D (r=-0.45, p<0.05) at Bsl correlated with their increases after supplementation. Supplemental vitamin D increased interferon (IFN)-γ and interleukin (IL)-10 in subjects that were vitamin D insufficient (serum 25(OH)D<29ng/mL) compared to sufficient (serum 25(OH)D⩾30ng/mL) at Bsl. We conclude that supplemental vitamin D increase a pro- and anti-inflammatory cytokine in those with initially low serum 25(OH)D. Copyright © 2014 Elsevier Ltd. All rights reserved.
Infrared Spectroscopy of Blood for Disease Identification
NASA Astrophysics Data System (ADS)
Pichardo, J. L.; Huerta-Franco, R.; Álvarez, R. R.; Bernal, J.; Gutiérrez-Juárez, G.; Palomares-Anda, P.
2003-09-01
Total reflectance attenuated infrared Fourier transform spectroscopy was used to analyze blood samples. Plasma and red blood cells were separated by centrifugation. The spectra were recorded from 200 to 4000 cm-1 under the same conditions for all samples. Samples of healthy donors were compared with those patients with different diseases (polycythemia and high blood pressure). Patients were under medical control at the time of the study. However, the preliminary results reveal that blood samples from healthy subjects had different infrared spectra compared to the non healthy patients.
McGregor, Tracy L.; Van Driest, Sara L.; Brothers, Kyle B.; Bowton, Erica A.; Muglia, Louis J.; Roden, Dan M.
2013-01-01
The Vanderbilt DNA repository, BioVU, links DNA from leftover clinical blood samples to de-identified electronic medical records. After initiating adult sample collection, pediatric extension required consideration of ethical concerns specific to pediatrics and implementation of specialized DNA extraction methods. In the first year of pediatric sample collection, over 11,000 samples were included from individuals younger than 18 years. We compared the pediatric BioVU cohort to the overall Vanderbilt University Medical Center pediatric population and found similar demographic characteristics; however, the BioVU cohort has higher rates of select diseases, medication exposures, and laboratory testing, demonstrating enriched representation of severe or chronic disease. This unbalanced sample accumulation may accelerate research of some cohorts, but also may limit study of relatively benign conditions and the accrual of unaffected and unbiased control samples. BioVU represents a feasible model for pediatric DNA biobanking but involves both ethical and practical considerations specific to the pediatric population. PMID:23281421
Elimination kinetics of metals after an accidental exposure to welding fumes.
Schaller, Karl H; Csanady, György; Filser, Johannes; Jüngert, Barbara; Drexler, Hans
2007-07-01
We had the opportunity to study the kinetics of metals in blood and urine samples of a flame-sprayer exposed to high accident-prone workplace exposure. We measured over 1 year, the nickel, aluminium, and chromium concentrations in blood and urine specimens after exposure. On this basis, we evaluated the corresponding half-lives. Blood and urine sampling were carried out five times after accidental exposure over a period of 1 year. The metals were analysed by graphite furnace atomic absorption spectrometry and Zeeman compensation with reliable methods. Either a mono-exponential or a bi-exponential function was fitted to the concentration-time courses of selected metals using weighted least squares non-linear regression analysis. The amount excreted in urine was calculated integrating the urinary decay curve and multiplying with the daily creatinine excretion. The first examination was carried out 15 days after exposure. The mean aluminium concentration in plasma was 8.2 microg/l and in urine, 58.4 microg/g creatinine. The mean nickel concentration in blood was 59.6 microg/l and the excretion in urine 700 microg/g creatinine. The mean chromium level in blood was 1.4 microg/l in urine, 7.4 microg/g creatinine. For the three elements, the metal concentrations in blood and urine exceeded the reference values at least in the initial phase. For nickel, the German biological threshold limit values (EKA) were exceeded. Aluminium showed a mono-exponential decay, whereas the elimination of chromium and nickel was biphasic in biological fluids of the accidentally exposed welder. The half-lives were as follows: for aluminium 140 days (urine) and 160 days (plasma); for chromium 40 and 730 days (urine); for nickel 25 and 610 days (urine) as well as 30 and 240 days (blood). The renal clearance of aluminium and nickel was about 2 l/h estimated for the last monitoring day.
Biological Basis for Chemoprevention of Ovarian Cancer
2003-10-01
birth control pill use are strongly protective. To achieve a better understanding of the etiology of ovarian cancer, which can then be translated into effective prevention strategies, we have initiated a case-control study that considers genetic susceptibility, epidemiologic risk factors and acquired genetic alterations. Subjects are interviewed in their homes and about 650 cases and 650 controls have been accrued thus far. Blood and cancer samples have been collected and molecular analyses of genetic polymorphisms (BRCA1/2, progesterone receptor) have been performed. An
Biological Basis for Chemoprevention of Ovarian Cancer
2004-10-01
birth control pill use are strongly protective. To achieve a better understanding of the etiology of ovarian cancer, which can then be translated into effective prevention strategies, we have initiated a case-control study that considers genetic susceptibility, epidemiologic risk factors and acquired genetic alterations. Subjects are interviewed in their homes and about 750 cases and 750 controls have been accrued thus far. Blood and cancer samples have been collected and molecular analyses of genetic polymorphisms (BRCA1/2, progesterone receptor, vitamin D receptor,
Cancer Moonshot Connecting International Liquid Biopsy Efforts Through Academic Partnership.
Dive, C; Shishido, S N; Kuhn, P
2017-05-01
The Kuhn Laboratory at the University of Southern California and the Dive Laboratory at the Cancer Research UK's Manchester Institute are teaming up to apply new cancer cell detection technology to identify patients who will progress after initial treatment. Researchers will take a simple blood sample to identify early those patients whose cancer has returned, while analyzing circulating tumor cells (CTCs) in great detail, providing new clues on the most effective therapy for the patient's cancer. © 2017 American Society for Clinical Pharmacology and Therapeutics.
2012-05-01
clinical presentations but typically presents as a flu-like illness. The most common chronic manifestation is endocarditis . Most providers are not...to years after initial infection.1,7 Manifestations of chronic infection may include endocarditis , other endovascular infec- tions, granulomatous... endocarditis conducted in France, PCR on blood or serum samples was positive in 23 of 70 patients (33%) tested.27 In a follow-up of 686 patients from the
2012-07-01
as an ‘‘index’’ case to initiate a positive cluster investigation around the index case house. Cohort children who were dengue PCR-negative from an ...were collected on days 0 and 15. Paired day 0 and 15 blood samples from child contacts were tested by both dengue PCR and an in-house dengue /Japanese...viral infections globally. An improved understanding of the spatial and temporal distribution of dengue virus (DENV) transmission between humans and
2017-10-01
mRNA and has been shown in many studies to improve predictive accuracy for cancer on initial biopsy,3,7-9 and to be correlated with more aggressive... Study (PASS). We are in the process of evaluating these three biomarker panels in tissue, blood, and urine samples with well annotated clinical and...during AS. The objective of the study is to utilize analytically validated assays that take into account tumor heterogeneity to measure biomarkers in
Quantitative blood group typing using surface plasmon resonance.
Then, Whui Lyn; Aguilar, Marie-Isabel; Garnier, Gil
2015-11-15
The accurate and reliable typing of blood groups is essential prior to blood transfusion. While current blood typing methods are well established, results are subjective and heavily reliant on analysis by trained personnel. Techniques for quantifying blood group antibody-antigen interactions are also very limited. Many biosensing systems rely on surface plasmon resonance (SPR) detection to quantify biomolecular interactions. While SPR has been widely used for characterizing antibody-antigen interactions, measuring antibody interactions with whole cells is significantly less common. Previous studies utilized SPR for blood group antigen detection, however, showed poor regeneration causing loss of functionality after a single use. In this study, a fully regenerable, multi-functional platform for quantitative blood group typing via SPR detection is achieved by immobilizing anti-human IgG antibody to the sensor surface, which binds to the Fc region of human IgG antibodies. The surface becomes an interchangeable platform capable of quantifying the blood group interactions between red blood cells (RBCs) and IgG antibodies. As with indirect antiglobulin tests (IAT), which use IgG antibodies for detection, IgG antibodies are initially incubated with RBCs. This facilitates binding to the immobilized monolayer and allows for quantitative blood group detection. Using the D-antigen as an example, a clear distinction between positive (>500 RU) and negative (<100 RU) RBCs is achieved using anti-D IgG. Complete regeneration of the anti-human IgG surface is also successful, showing negligible degradation of the surface after more than 100 regenerations. This novel approach is validated with human-sourced whole blood samples to demonstrate an interesting alternative for quantitative blood grouping using SPR analysis. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.
Long-term stability of glucose: glycolysis inhibitor vs. gel barrier tubes.
Winter, Theresa; Hannemann, Anke; Suchsland, Juliane; Nauck, Matthias; Petersmann, Astrid
2018-03-12
Measuring the glucose concentration in whole blood samples is critical due to unsatisfactory glycolysis inhibition. Previous studies showed that Terumo tubes were superior, but they were taken off the European market in 2016 and alternatives were required. This initiated the present evaluation of glucose stability in five available tube types. Venous blood samples were collected from 61 healthy volunteers to test tubes supplied by Terumo (two sets), Greiner FC-Mix, BD FX-Mixture and BD serum. After sampling, the contents were thoroughly mixed and centrifuged within an hour. The glucose concentrations were determined and the samples resuspended except for BD serum tubes (gel barrier). The first 30 samples were stored at room temperature and the remaining 31 at 4°C. After 24, 48, 72 and 96 h, all tubes were (re)centrifuged, and glucose concentration measurements were repeated. Changes in glucose concentrations over time differed significantly between the investigated tube types and to a certain extent between the two storing conditions. Glycolysis was most evident in the BD FX-mixture tubes. Good glucose stability was observed in samples retrieved form BD serum and Greiner tubes. The stability in both Terumo tubes was comparable to that in other studies. Although Greiner and both Terumo tubes are supposed to contain the same glycolysis inhibitor, glucose stability differed between these tubes. We showed that Greiner is an acceptable alternative to Terumo and that glucose in serum that was rapidly separated from corpuscles by a gel barrier is stable for an extended time.
Differential white cell count by centrifugal microfluidics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.
We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generationmore » of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.« less
A motivational interview promotes retention of blood donors with high internal motivation.
France, Christopher R; France, Janis L; Carlson, Bruce W; Himawan, Lina K; Kessler, Debra A; Rebosa, Mark; Shaz, Beth H; Madden, Katrala; Carey, Patricia M; Slepian, P Maxwell; Ankawi, Brett; Livitz, Irina E; Fox, Kristen R
2017-10-01
Based on the hypothesis that self-determined motivation is associated with an increased likelihood of future behavior, the present study examined the ability of a motivational interview to promote internal motivation for giving blood and future donation attempts. A sample of 484 recent whole-blood and double red blood cell donors (62.4% female; age = 30.2 ± 11.8 years) were randomly assigned to either a telephone-delivered motivational interview or a control call approximately 6 weeks after donating. Several weeks before the call and again 1 week after the call, participants completed the Blood Donor Identity Survey, a multidimensional measure of donor motivation, to derive indices of amotivation, external motivation, and internal motivation to give blood. Repeat donation attempts were tracked using blood center records. Relative to controls, participants in the motivational interview group showed a shift toward more self-determined motivation, as indicated by significant decreases in amotivation (p = 0.01) and significant increases in external (p = 0.009) and internal (p = 0.002) motivation. Furthermore, those with initially high levels of autonomous motivation were more likely to make a donation attempt in the subsequent year if they completed the motivational interview (71.1%) versus the control call (55.1%). Motivational interviewing is a potentially useful strategy to enhance retention of existing blood donors, particularly among those who express a greater sense of internal motivation for giving. © 2017 AABB.
NHEXAS PHASE I MARYLAND STUDY--LIPIDS IN BLOOD ANALYTICAL RESULTS
The Lipids in Blood data set presents concentrations of cholesterol and total triglycerides in blood serum. The data set presents measurements for up to 2 lipids in 358 blood samples over 79 households. Each sample was collected via a venous sample from the primary respondent w...
Dastjerdi, Akbar; Seilern-Moy, Katharina; Darpel, Karin; Steinbach, Falko; Molenaar, Fieke
2016-08-27
Elephant Endotheliotropic Herpesviruses (EEHVs) can cause acute haemorrhagic disease in young Asian elephants (Elephas maximus) and clinical EEHV infections account for the majority of their fatalities. The anti-herpesviral drug famciclovir (FCV) has been used routinely to treat viraemic at-risk elephants, but thus far without proven efficacy. This paper presents clinical and virological investigations of two EEHV-1A infected elephants treated with FCV, and discusses anti-herpesvirus therapies of viraemic elephants. Two 1.5 year old male Asian elephants at a zoological collection in the UK developed clinical EEHV-1A infections. Case 1 showed signs of myalgia for the duration of 24 hours before returning back to normal. EEHV-1A DNAemia was confirmed on the day of clinical signs and continued to be present for 18 days in total. Trunk shedding of the virus commenced 10 days after detection of initial DNAemia. Case 2 tested positive for EEHV-1A DNAemia in a routine blood screening sample in the absence of clinical signs. The blood viral load increased exponentially leading up to fatal clinical disease seven days after initial detection of DNAemia. Both calves were treated with 15 mg/kg FCV per rectum on detection of DNAemia and penciclovir, the FCV metabolite, could be detected in the blood at assumed therapeutic levels. The early indicators for clinical disease were a marked absolute and relative drop in white blood cells, particularly monocytes prior to the detection of viraemia. The most prognostic haematological parameter at later stages of the disease was the platelet count showing a continuous sharp decline throughout, followed by a dramatic drop at the time of death. The EEHV-1A viraemic animals investigated here further highlight the ongoing threat posed by these viruses to juvenile Asian elephants. The findings call into question the efficacy of rectal FCV in clinical cases and direct towards the use of alternative anti-herpesvirus drugs and complementary treatments such as plasma infusions if no improvement in either viral load or the above-mentioned blood parameters are observed in the initial days of viraemia despite anti-herpesvirus therapy.
Jabs, Douglas A.; Forman, Michael; Enger, Cheryl; Jackson, J. Brooks
1999-01-01
Cytomegalovirus (CMV) DNA loads in paired leukocyte and plasma samples from 199 patient visits by 66 patients with CMV retinitis were determined. Leukocyte CMV load determinations had a greater range of values (mean, 24,587 copies/106 leukocytes; maximum, 539,000) than did plasma CMV load determinations (mean, 10,302 copies/ml; maximum, 386,000), and leukocyte viral loads were detectable in a greater proportion of patients at the time of diagnosis of CMV retinitis prior to initiation of anti-CMV therapy (82%) than were plasma viral loads (64%) (P = 0.0078). Agreement with CMV blood cultures was slightly better for plasma (κ = 0.68) than for leukocytes (κ = 0.53), due to a greater proportion of patients with detectable viral loads in leukocytes having negative blood cultures. PMID:10203500
Castelló, Ana; Francès, Francesc; Verdú, Fernando
2017-09-01
Presumptive tests for blood are very simple and sensitive tests used in the search for evidence. They also provide initial information on the nature of stains. A second test can confirm their nature. However, these tests can present false-negative results for different reasons. Some of those reasons have been studied, while others, those caused by the substrate material that contains the stain, are less well known. This work studies the effect of one component of a leather substrate-quebracho extract-on presumptive and human hemoglobin blood tests. Assays were performed using samples of blood dilutions contaminated with quebracho extract and others formed on a substrate containing the contaminant. Results show an undoubted interference that causes false negatives and even visible to the naked eye stains and also indicate that some tests (phenolphthalein) are more affected than others. Examiners should be taken into account when working on this kind of substrates. © 2017 American Academy of Forensic Sciences.
Chahine, George; Short, Baron; Spicer, Ken; Schmidt, Matthew; Burns, Carol; Atoui, Mia; George, Mark S; Sackeim, Harold A; Nahas, Ziad
2014-01-01
Use of electroconvulsive therapy (ECT) is limited by cognitive disturbance. Focal electrically-administered seizure therapy (FEAST) is designed to initiate focal seizures in the prefrontal cortex. To date, no studies have documented the effects of FEAST on regional cerebral blood flow (rCBF). A 72 year old depressed man underwent three single photon emission computed tomography (SPECT) scans to capture the onset and resolution of seizures triggered with right unilateral FEAST. We used Bioimage Suite for within-subject statistical analyses of perfusion differences ictally and post-ictally compared with the baseline scan. Early ictal increases in regional cerebral blood flow (rCBF) were limited to the right prefrontal cortex. Post-ictally, perfusion was reduced in bilateral frontal and occipital cortices and increased in left motor and precuneus cortex. FEAST appears to triggers focal onsets of seizure activity in the right prefrontal cortex with subsequent generalization. Future studies are needed on a larger sample. Copyright © 2014 Elsevier Inc. All rights reserved.
Kalathia, Mitul Babubhai; Shingala, Prakash Ashokbhai; Parmar, Parin Niranjanbhai; Parikh, Yogesh Narenedrabhai; Kalathia, Ila Mitulkumar
2013-10-01
Blood culture is gold standard for diagnosis of neonatal sepsis. Low sensitivity of blood culture is usually due to small volume of blood sample, intrapartum antibiotics, and antibiotics given to newborn before sampling. We evaluated use of Umbilical cord blood culture (UCBC) in diagnosis of neonatal sepsis as compared to peripheral venous blood culture. This study was done in tertiary care teaching hospital during May-June 2012. A total of 45 newborns with presence of two or more risk factors of sepsis were included. Blood sample from placental end of umbilical cord was collected and cultured. Primary outcome was diagnosis of neonatal sepsis by use of umbilical cord blood sample as compared with venous blood sample. Secondary outcome was to compare organisms identified by UCBC and venous blood culture. Sensitivity, specificity, positive and negative predictive values of UCBC were calculated. A total of 24.44% (11 out of 45) high-risk newborns had positive UCBC. A total of 17.8% (8 out of 45) newborns had positive blood culture report. Organisms grown in UCBC were Pseudomonas (45%, 5 out of 11), Acinetobacter (27.27%, 3 out of 11), Escherichia coli (18.18%, 2 out of 11), and Klebsiella (9%, 1 out of 11). UCBC is a good method for diagnosis of neonatal sepsis among high-risk newborns as compared to venous blood culture with a sensitivity of 80% and specificity of 91.43%. Organisms grown are comparable to blood culture samples.
Patient identification in blood sampling.
Davidson, Anne; Bolton-Maggs, Paula
The majority of adverse reports relating to blood transfusions result from human error, including misidentification of patients and incorrect labelling of samples. This article outlines best practice in blood sampling for transfusion (but is recommended for all pathology samples) and the role of patient empowerment in improving safety.
Eshoo, Mark W.; Crowder, Christopher C.; Rebman, Alison W.; Rounds, Megan A.; Matthews, Heather E.; Picuri, John M.; Soloski, Mark J.; Ecker, David J.; Schutzer, Steven E.; Aucott, John N.
2012-01-01
Direct molecular tests in blood for early Lyme disease can be insensitive due to low amount of circulating Borrelia burgdorferi DNA. To address this challenge, we have developed a sensitive strategy to both detect and genotype B. burgdorferi directly from whole blood collected during the initial patient visit. This strategy improved sensitivity by employing 1.25 mL of whole blood, a novel pre-enrichment of the entire specimen extract for Borrelia DNA prior to a multi-locus PCR and electrospray ionization mass spectrometry detection assay. We evaluated the assay on blood collected at the initial presentation from 21 endemic area patients who had both physician-diagnosed erythema migrans (EM) and positive two-tiered serology either at the initial visit or at a follow-up visit after three weeks of antibiotic therapy. Results of this DNA analysis showed detection of B. burgdorferi in 13 of 21 patients (62%). In most cases the new assay also provided the B. burgdorferi genotype. The combined results of our direct detection assay with initial physician visit serology resulted in the detection of early Lyme disease in 19 of 21 (90%) of patients at the initial visit. In 5 of 21 cases we demonstrate the ability to detect B. burgdorferi in early Lyme disease directly from whole blood specimens prior to seroconversion. PMID:22590620
Heim, Albert
2016-05-01
The performance of the multiplex Procleix Ultrio Elite assay as individual donor nucleic acid test (ID-NAT) for the detection of HIV-1, HIV-2, HCV, and HBV was evaluated in a retrospective, single center study. ID-NAT results of 21,181 blood donors, 984 tissue donors, 293 hematopoietic stem cell donors and 4 organ donors were reviewed in synopsis with results of serological screening and additional discriminatory and repetitive NAT in case of positive donors. Specificity of the initial Procleix Ultrio Elite assay was 99.98% and after discriminatory testing 100.00%. Initially invalid results were observed in 75 of 21,181 blood donors (0.35%) but 16 of 984 tissue donors (1.62%, p < 0.001) which included non-heart-beating ('cadaveric') donors. All these had valid negative ID-NAT results after repeated testing or testing of 1:5 diluted specimens in case of tissue donors. Occult hepatitis B (defined here as HBV DNAemia without HBsAg detection) was demonstrated by ID-NAT in two anti-HBc-positive tissue donors and suspected in two other tissue donors, where a definite diagnosis was not achieved due to the insufficient sample volumes available. The Procleix Ultrio Elite assay proved to be specific, robust and rapid. Therefore, routine ID-NAT may also be feasible for organ and granulocyte donors.
Bronsert, Michael R; Henderson, William G; Valuck, Robert; Hosokawa, Patrick; Hammermeister, Karl
2013-01-01
Few comparative effectiveness studies of treatment strategies using antihypertensive therapeutic classes in hypertension control have been assessed in a primary care environment. The objectives are to compare the effectiveness of common antihypertensive therapeutic classes initiated as monotherapy and of fixed-dose combinations (FDCs), free-equivalent combinations (FECs), and monotherapy on hypertension control. This article reports observational comparative effectiveness analyses of data electronically extracted from electronic health records. The study population consisted of 8,676 patients with an incident prescription for an antihypertensive agent of a total of 79,176 patients receiving antihypertensive therapy in 33 geographically diverse primary care clinics. The main measures were reductions in systolic blood pressure (SBP) and diastolic blood pressure (DBP) and rates of attaining goals per the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure (JNC7). There were small, clinically insignificant differences in blood pressure reductions between the monotherapy classes. Higher rates of blood pressure control were obtained when patients were initiated on an angiotensin-converting enzyme inhibitor than a thiazide or thiazide-like diuretic (47.8% vs 39.9%) or a β-blocker versus a thiazide (45.9% vs 39.9%). Patients initiated on FDCs had significantly larger reductions in blood pressure than patients initiated on FECs (-17.3 vs -12.0 mm Hg SBP; -10.1 vs -6.0 mm Hg DBP) or monotherapy (-17.3 vs -13.6 mm Hg SBP; -10.1 vs -7.9 mm Hg DBP). Rates of attaining JNC7 goals also were better for FDCs than FECs (57.2% vs 42.5%) and for FDCs versus monotherapy (57.2% vs 44.9%). Patients initiated on angiotensin-converting enzyme inhibitors and β-blockers had slightly higher rates of blood pressure control. The use of FDCs as initial therapy is more effective in the control of hypertension than monotherapy or FECs.
Sampling and storage of blood for pH and blood gas analysis.
Haskins, S C
1977-02-15
Techniques used in sampling and storage of a blood sample for pH and gas measurements can have an important effect on the measured values. Observation of these techniques and principles will minimize in vitro alteration of the pH and blood gas values. To consider that a significant change has occurred in a pH or blood gas measurement from previous values, the change must exceed 0.015 for pH, 3 mm Hg for PCO2, 5 mm Hg for PO2, and 2 mEq/L for [HCO-3] or base excess/deficit. In vitro dilution of the blood sample with anticoagulant should be avoided because it will alter the measured PCO2 and base excess/deficit values. Arterial samples should be collected for meaningful pH and blood gas values. Central venous and free-flowing capillary blood can be used for screening procedures in normal patients but are subject to considerable error. A blood sample can be stored for up to 30 minutes at room temperature without significant change in acid-base values but only up to 12 minutes before significant changes occur in PO2. A blood sample can be stored for up to 3.5 hours in an ice-water bath without significant change in pH and for 6 hours without significant change in PCO2 or PO2. Variations of body temperatures from normal will cause a measurable change in pH and blood gas values when the blood is exposed to the normal water bath temperatures of the analyzer.
Vriens, Dennis; de Geus-Oei, Lioe-Fee; Oyen, Wim J G; Visser, Eric P
2009-12-01
For the quantification of dynamic (18)F-FDG PET studies, the arterial plasma time-activity concentration curve (APTAC) needs to be available. This can be obtained using serial sampling of arterial blood or an image-derived input function (IDIF). Arterial sampling is invasive and often not feasible in practice; IDIFs are biased because of partial-volume effects and cannot be used when no large arterial blood pool is in the field of view. We propose a mathematic function, consisting of an initial linear rising activity concentration followed by a triexponential decay, to describe the APTAC. This function was fitted to 80 oncologic patients and verified for 40 different oncologic patients by area-under-the-curve (AUC) comparison, Patlak glucose metabolic rate (MR(glc)) estimation, and therapy response monitoring (Delta MR(glc)). The proposed function was compared with the gold standard (serial arterial sampling) and the IDIF. To determine the free parameters of the function, plasma time-activity curves based on arterial samples in 80 patients were fitted after normalization for administered activity (AA) and initial distribution volume (iDV) of (18)F-FDG. The medians of these free parameters were used for the model. In 40 other patients (20 baseline and 20 follow-up dynamic (18)F-FDG PET scans), this model was validated. The population-based curve, individually calibrated by AA and iDV (APTAC(AA/iDV)), by 1 late arterial sample (APTAC(1 sample)), and by the individual IDIF (APTAC(IDIF)), was compared with the gold standard of serial arterial sampling (APTAC(sampled)) using the AUC. Additionally, these 3 methods of APTAC determination were evaluated with Patlak MR(glc) estimation and with Delta MR(glc) for therapy effects using serial sampling as the gold standard. Excellent individual fits to the function were derived with significantly different decay constants (P < 0.001). Correlations between AUC from APTAC(AA/iDV), APTAC(1 sample), and APTAC(IDIF) with the gold standard (APTAC(sampled)) were 0.880, 0.994, and 0.856, respectively. For MR(glc), these correlations were 0.963, 0.994, and 0.966, respectively. In response monitoring, these correlations were 0.947, 0.982, and 0.949, respectively. Additional scaling by 1 late arterial sample showed a significant improvement (P < 0.001). The fitted input function calibrated for AA and iDV performed similarly to IDIF. Performance improved significantly using 1 late arterial sample. The proposed model can be used when an IDIF is not available or when serial arterial sampling is not feasible.
Impact of the moon on cerebral aneurysm rupture.
Kamp, Marcel A; Dibué, Maxine; Slotty, Philipp; Steiger, Hans-Jakob; Hänggi, Daniel
2013-08-01
Several external and internal risk factors for cerebral aneurysm rupture have been identified to date. Recently, it has been reported that moon phases correlate with the incidence of aneurysmal subarachnoid hemorrhage (SAH), however, another author found no such association. Therefore, the present study investigates the influence of the lunar cycle on the incidence of aneurysmal rupture, the initial clinical presentation, and the amount of subarachnoid blood. Lunar phase and the particular day of the lunar cycle were correlated to the date of aneurysm rupture, aneurysm location, initial clinical presentation, and amount of subarachnoid blood assessed from CT scans of all patients treated for basal SAH in our department from 2003 to 2010. We found no correlation between incidence of aneurysmal SAH, location of the aneurysm, initial clinical presentation, or amount of subarachnoid blood and the lunar cycle. The moon influences neither the incidence of aneurysmal SAH nor the grade of initial neurological deterioration or amount of subarachnoid blood.
Enhancing blood donation intentions using multimedia donor education materials.
France, Christopher R; France, Janis L; Wissel, Mary Ellen; Kowalsky, Jennifer M; Bolinger, Elizabeth M; Huckins, Jamie L
2011-08-01
Prior research has shown that education materials that directly address prospective donor concerns and provide specific coping suggestions are particularly effective at enhancing donation attitudes and intentions to give blood. This study compared the effect of donor coping materials, provided in written and audiovisual formats, as potential tools to enhance recruitment of prospective blood donors. The role of initial attitudes toward blood donation on responses to these materials was also considered. Young adults (62% female; mean [SD] age=19.1 [1.4]; mean [range] prior blood donations=1.32 [0-13]) were randomly assigned to 1) read a brochure addressing common blood donor concerns and suggesting specific coping strategies, 2) view a video addressing blood donor concerns and illustrating coping techniques, 3) read the brochure and view the video, or 4) read a control brochure on healthy eating and exercise. Measures of blood donation attitudes, anxiety, confidence, and intentions to give blood were completed before and after the intervention. Relative to the control brochure, all the intervention groups showed larger reductions in anxiety, more positive changes in attitude, and greater increases in donation confidence and intentions. The combination of the brochure and video outperformed either intervention alone in further improving donation attitudes among participants with high initial donation attitudes. Blood donation coping materials, presented in either written or audiovisual formats, significantly enhance willingness to donate blood among young adults regardless of their initial attitudes toward blood donation. © 2011 American Association of Blood Banks.
Method of high-precision microsampled blood and plasma mass densitometry
NASA Technical Reports Server (NTRS)
Hinghofer-Szalkay, H.
1986-01-01
The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.
Blood ammonia and lactate as markers of muscle metabolites during leg press exercise.
Gorostiaga, Esteban M; Navarro-Amézqueta, Ion; Calbet, Jose A L; Sánchez-Medina, Luis; Cusso, Roser; Guerrero, Mario; Granados, Cristina; González-Izal, Miriam; Ibáñez, Javier; Izquierdo, Mikel
2014-10-01
To examine whether blood lactate and ammonia concentrations can be used to estimate the functional state of the muscle contractile machinery with regard to muscle lactate and adenosine triphosphate (ATP) levels during leg press exercise. Thirteen men (age, 34 ± 5 years; 1 repetition maximum leg press strength 199 ± 33 kg) performed either 5 sets of 10 repetitions to failure (5×10RF), or 10 sets of 5 repetitions not to failure (10×5RNF) with the same initial load (10RM) and interset rests (2 minutes) on 2 separate sessions in random order. Capillary blood samples were obtained before and during exercise and recovery. Six subjects underwent vastus lateralis muscle biopsies at rest, before the first set and after the final exercise set. The 5×10RF resulted in a significant and marked decrease in power output (37%), muscle ATP content (24%), and high levels of muscle lactate (25.0 ± 8.1 mmol·kg wet weight), blood lactate (10.3 ± 2.6 mmol·L), and blood ammonia (91.6 ± 40.5 μmol·L). During 10×5RNF no or minimal changes were observed. Significant correlations were found between: (a) blood ammonia and muscle ATP (r = -0.75), (b) changes in peak power output and blood ammonia (r = -0.87) and blood lactate (r = -0.84), and (c) blood and muscle lactate (r = 0.90). Blood lactate and ammonia concentrations can be used as extracellular markers for muscle lactate and ATP contents, respectively. The decline in mechanical power output can be used to indirectly estimate blood ammonia and lactate during leg press exercise.
A technique for extracting blood samples from mice in fire toxicity tests
NASA Technical Reports Server (NTRS)
Bucci, T. J.; Hilado, C. J.; Lopez, M. T.
1976-01-01
The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.
Rutten, Niels; Gonzales, José L.; Elbers, Armin R. W.; Velthuis, Annet G. J.
2012-01-01
Background As low pathogenic avian influenza viruses can mutate into high pathogenic viruses the Dutch poultry sector implemented a surveillance system for low pathogenic avian influenza (LPAI) based on blood samples. It has been suggested that egg yolk samples could be sampled instead of blood samples to survey egg layer farms. To support future decision making about AI surveillance economic criteria are important. Therefore a cost analysis is performed on systems that use either blood or eggs as sampled material. Methodology/Principal Findings The effectiveness of surveillance using egg or blood samples was evaluated using scenario tree models. Then an economic model was developed that calculates the total costs for eight surveillance systems that have equal effectiveness. The model considers costs for sampling, sample preparation, sample transport, testing, communication of test results and for the confirmation test on false positive results. The surveillance systems varied in sampled material (eggs or blood), sampling location (farm or packing station) and location of sample preparation (laboratory or packing station). It is shown that a hypothetical system in which eggs are sampled at the packing station and samples prepared in a laboratory had the lowest total costs (i.e. € 273,393) a year. Compared to this a hypothetical system in which eggs are sampled at the farm and samples prepared at a laboratory, and the currently implemented system in which blood is sampled at the farm and samples prepared at a laboratory have 6% and 39% higher costs respectively. Conclusions/Significance This study shows that surveillance for avian influenza on egg yolk samples can be done at lower costs than surveillance based on blood samples. The model can be used in future comparison of surveillance systems for different pathogens and hazards. PMID:22523543
NHEXAS PHASE I MARYLAND STUDY--PESTICIDES IN BLOOD ANALYTICAL RESULTS
The Pesticides in Blood Serum data set contains analytical results for measurements of up to 17 pesticides in 358 blood samples over 79 households. Each sample was collected via a venous sample from the primary respondent within each household by a phlebotomist. Samples were ge...
Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka
2015-01-01
Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia. PMID:26524965
Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka
2015-01-01
Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia.
Probable transfusion-transmitted Zika virus in Brazil.
Barjas-Castro, Maria L; Angerami, Rodrigo N; Cunha, Mariana S; Suzuki, Akemi; Nogueira, Juliana S; Rocco, Iray M; Maeda, Adriana Y; Vasami, Fernanda G S; Katz, Gizelda; Boin, Ilka F S F; Stucchi, Raquel S B; Resende, Mariângela R; Esposito, Danillo L A; de Souza, Renato P; da Fonseca, Benedito A; Addas-Carvalho, Marcelo
2016-07-01
Zika virus (ZIKV) is an emerging arthropod-borne flavivirus transmitted by Aedes mosquitoes. Recent commentaries regarding ZIKV routes of transmission describe a potential transmission by transfusion. Herein, we report a probable case of transfusion-transmitted ZIKV infection through a platelet transfusion that was detected from postdonation information. A blood donor made a voluntary telephone report to the blood donor facility 3 days after donation and informed the facility of a febrile illness (fever, malaise, and headaches). Due to the ongoing dengue epidemic, the initial clinical investigation included dengue among other possible diagnoses. The serology and molecular laboratory results excluded dengue infection. However, stored samples from the donation were positive for ZIKV on reverse transcription-polymerase chain reaction (RT-PCR) analysis. A retrospective investigation demonstrated that the platelet concentrate, which was part of a pool, had been transfused after a liver transplantation. A physician had evaluated the patient 4 days after surgery. Laboratory investigation showed enzyme-linked immunosorbent assay results that were negative for dengue immunoglobulin M antibodies; however, the results were positive for hemagglutination inhibition antibodies against flavivirus. ZIKV RT-PCR and virus isolation analyses in cell cultures from recipient serum were both positive. The sequencing confirmed ZIKV in the donor and patient samples. Ten partial nucleotide sequences from the ZIKV strain that were detected in the donor were aligned and compared with the ZIKV genome detected in the recipient, revealing a 99.8% homology between the two strains. This is a case of probable transmission of ZIKV through blood transfusion. The patient had been transfused with the blood product from an infected donor, most likely in the incubation period after ZIKV infection but prior to clinical disease onset. This report emphasizes the importance of postdonation information and recipient investigations during outbreaks of potentially blood-borne infections. © 2016 AABB.
Pinto, Ana Yecê das Neves; Valente, Vera da Costa; Coura, José Rodrigues; Valente, Sebastião Aldo da Silva; Junqueira, Angela Cristina Veríssimo; Santos, Laura Cristina; Ferreira, Alberto Gomes; de Macedo, Roberto Cavalleiro
2013-01-01
A total of 179 individuals with acute Chagas disease mainly transmitted by oral source, from Pará and Amapá State, Amazonian, Brazil were included during the period from 1988 to 2005. Blood samples were used to survey peripheral blood for T. cruzi hemoparasites by quantitative buffy coat (QBC), indirect xenodiagnosis, blood culture and serology to detection of total IgM and anti-T. cruzi IgG antibodies by indirect immunofluorescence assay (IFA) and indirect hemagglutination assay (HA). All assays were performed pre-treatment (0 days) and repeated 35 (±7) and 68 (±6) days after the initiation of treatment with benznidazol and every 6 months while remained seropositive. The endpoint of collection was performed in 2005. Total medium period of follow-up per person was 5.6 years. Also, a blood sample was collected from 72 randomly chosen treated patients to perform polimerase chain reaction (PCR) method. Proportions of subjects with negative or positive serology according to the number of years after treatment were compared. In the endpoint of follow-up we found 47 patients (26.7%) serologically negative, therefore considered cured and 5 (2.7%) exhibited mild cardiac Chagas disease. Other 132 patients had persistent positive serologic tests. The PCR carried out in 72 individuals was positive in 9.8%. Added, there was evidence of therapeutic failure immediately following treatment, as demonstrated by xenodiagnosis and blood culture methods in 2.3% and 3.5% of cases, respectively. There was a strong evidence of antibody clearing in the fourth year after treatment and continuous decrease of antibody titers. Authors suggest that control programs should apply operational researches with new drug interventions four years after the acute phase for those treated patients with persistently positive serology. PMID:23724050
Health and environmental assessment of the impact of mine tailings spillage in the Philippines
NASA Astrophysics Data System (ADS)
Castillo, E.; Cortes-Maramba, N. P.; Reyes, J. P.; Makalinao, I.; Dioquino, C.; Francisco-Rivera, A. T.; Timbang, R.
2003-05-01
In March, 1997, a municipal health officer in a small island south of Manila requested for the conduct of a health assessment of the community because of the incidence of hematological related illnesses/mortality among residents of along the coastal area of a mining community. 85 deaths were recorded from 1975-1996. Leukemia was diagnosed in 62 (72.94%) patients, 16 (18.82%) were aplastic anemia, 4 (4.71%) were blood dyscrasia and 3 (3.53%) other blood related ailments. Health and environmental assessment activities were conducted by a composite team from the DOH and the UP-National Poisons Control and Information Service Health examinations included a review of systems, complete medical history, physical and neurologic evaluations and biologic examinations. Initial health examination showed 7 schoolchildren out of 108 volunteer subjects from 6 barangays have elevated blood lead levels exceeding the WHO recommended limits of 10 ug/dl. Mean blood lead levels = 15.86 ug/dl (Range: 13-19 ug/dl). Electromyograph and nerve conduction velocity (EMG-NCV) results were compatible with peripheral axonal degeneration in 6 children and beginning damage in 1 child. Detoxification therapy was done for a 19 day course using dimercaptosuccinic acid (DMSA). In the succeeding health assessment, 59/59 schoolchildren from 3 barangays namely were found to have elevated blood lead levels. Range: 10-18 ug/dl. 43/64 (67.18%) have anemia. Soil samples collected 7 km from the causeway and the causeway itself showed three (3) sites with lead. cadmium, copper and zinc levels were found in all sampling sites. Ambient air monitoring results showed lead values exceeding the recommended US-EPA limits.
Detection of antileishmanial antibodies in blood sampled from blood bank donors in Istanbul.
Ates, Sezen Canim; Bagirova, Malahat; Allahverdiyev, Adil M; Baydar, Serap Yesilkir; Koc, Rabia Cakir; Elcicek, Serhat; Abamor, Emrah Sefik; Oztel, Olga Nehir
2012-06-01
According to the WHO, only 5-20% of the total cases of leishmaniasis are symptomatic leishmaniasis; the other cases are identified as asymptomatic leishmaniasis. In recent studies, it has been demonstrated that donor blood plays an important role in the epidemiology of asymptomatic leishmaniasis. However, the number of the studies on this subject is still insufficient. Additionally, donor blood samples obtained from Istanbul, which is the biggest metropolitan area in Turkey, have not been investigated with regard to Leishmania. Moreover, there is no information about the sensitivity of noninvasive serological methods that are used in the detection of leishmaniasis donor blood samples. Accordingly, this study aimed to investigate the presence of antileishmanial antibodies in blood samples obtained from blood bank donors in Istanbul, by using different serologic methods, and to determine the most sensitive detection method. Blood samples were taken from 188 healthy blood bank donors to the Capa Turkish Red Crescent Blood Bank (Istanbul, Turkey), and the presence of antileishmanial antibodies was measured by indirect immunofluorescent antibody test (IFAT), ELISA, immunochromatographic dipstick rapid test, and western blot (WB). Antileishmanial antibodies were determined in 12 out of 188 samples by IFAT (6.4%), and six out of these 12 donors were found to be positive at diagnostic titer 1:128 (3.2%). One hundred and eighty eight samples were investigated by ELISA and one (0.5%) of them gave a positive result. None of 188 samples provided a positive result by immunochromatographic test. WB applied to the 12 seroreactive donors showed that three out of 12 donors were positive. In this study, the presence of antileishmanial antibodies in blood samples of blood bank donors from Istanbul has been demonstrated by using feasible and low-cost serological methods. Additionally, in comparison with other simple and low-cost detection methods, WB was used for confirmation. IFAT has a higher sensitivity and therefore may be preferred as a prescreening method in endemic or nonendemic areas.
Growth hormone suppression test
GH suppression test; Glucose loading test; Acromegaly - blood test; Gigantism - blood test ... At least 3 blood samples are taken. The test is done in the following way: The first blood sample is collected between 6 ...
Fair, Patricia A; Schaefer, Adam M; Romano, Tracy A; Bossart, Gregory D; Lamb, Stephen V; Reif, John S
2014-09-15
There is a growing concern about the impacts of stress in marine mammals as they face a greater array of threats. The stress response of free-ranging dolphins (Tursiops truncatus) was examined by measuring their physiologic response to capture and handling. Samples were collected from 168 dolphins during capture-release health assessments 2003-2007 at two study sites: Charleston, SC (CHS) and the Indian River Lagoon, FL (IRL). Adrenocorticotropic hormone (ACTH), cortisol, aldosterone (ALD) and catecholamines (epinephrine (EPI), norepinephrine (NOR), dopamine (DA)), were measured in blood and cortisol in urine. Mean time to collect pre-examination samples after netting the animals was 22min; post-examination samples were taken prior to release (mean 1h 37min). EPI and DA concentrations decreased significantly with increased time to blood sampling. ACTH and cortisol levels increased from the initial capture event to the post-examination sample. EPI concentrations increased significantly with increasing time to the pre-examination sample and decreased significantly with time between the pre- and post-examination sample. Cortisol concentrations increased between the pre- and post-examination in CHS dolphins. Age- and sex-adjusted mean pre-examination values of catecholamines were significantly higher in CHS dolphins; ALD was higher in IRL dolphins. Significant differences related to age or sex included higher NOR concentrations in males; higher ALD and urine cortisol levels in juveniles than adults. Wild dolphins exhibited a typical mammalian response to acute stress of capture and restraint. Further studies that relate hormone levels to biological and health endpoints are warranted. Published by Elsevier Inc.
Oroszlán, Gábor; Dani, Ráhel; Szilágyi, András; Závodszky, Péter; Thiel, Steffen; Gál, Péter; Dobó, József
2017-01-01
Serine proteases (SPs) are typically synthesized as precursors, termed proenzymes or zymogens, and the fully active form is produced via limited proteolysis by another protease or by autoactivation. The lectin pathway of the complement system is initiated by mannose-binding lectin (MBL)-associated SPs (MASP)-1, and MASP-2, which are known to be present as proenzymes in blood. The third SP of the lectin pathway, MASP-3, was recently shown to be the major activator, and the exclusive "resting blood" activator of profactor D, producing factor D, the initiator protease of the alternative pathway. Because only activated MASP-3 is capable of carrying out this cleavage, it was presumed that a significant fraction of MASP-3 must be present in the active form in resting blood. Here, we aimed to detect active MASP-3 in the blood by a more direct technique and to quantitate the active to zymogen ratio. First, MASPs were partially purified (enriched) from human plasma samples by affinity chromatography using immobilized MBL in the presence of inhibitors. Using this MASP pool, only the zymogen form of MASP-1 was detected by Western blot, whereas over 70% MASP-3 was in an activated form in the same samples. Furthermore, the active to zymogen ratio of MASP-3 showed little individual variation. It is enigmatic how MASP-3, which is not able to autoactivate, is present mostly as an active enzyme, whereas MASP-1, which has a potent autoactivation capability, is predominantly proenzymic in resting blood. In an attempt to explain this phenomenon, we modeled the basal level fluid-phase activation of lectin pathway proteases and their subsequent inactivation by C1 inhibitor and antithrombin using available and newly determined kinetic constants. The model can explain extensive MASP-3 activation only if we assume efficient intracomplex activation of MASP-3 by zymogen MASP-1. On the other hand, the model is in good agreement with the fact that MASP-1 and -2 are predominantly proenzymic and some of them is present in the form of inactive serpin-protease complexes. As an alternative hypothesis, MASP-3 activation by proprotein convertases is also discussed.
[Participation of leucocytes in pathogenesis of primary forms of lower limb chronic venous disease].
Bogachev, V Iu; Golovanova, O V; Sergeeva, N A; Kuznetsov, A N
2011-01-01
The purpose of the study was to test the hypothesis on participation of WBCs in damaging the venous wall in patients presenting with primary forms of lower limb chronic venous diseases LLCVD . The study included a total of fifteen consecutively selected patients (13 women and 2 men) diagnosed as having grade C2-C-4 LLCVD according to the CEAP classification. Static loading (30 minutes in the sitting position) was followed by simultaneous sampling of blood from the varicose vein of the cms and ulnar vein. The total blood count including determination of both the absolute values and percentage of blood formed elements was performed using the automated haematological counter «Advia 7» («Bayer», USA). The obtained findings were statistically processed using the Microsoft Office Excel software by means of the pared two-sample τ-test for the average values. The number of leukocytes and their subpopulations in blood samples obtained from the crural varicose veins turned out to be significantly less as compared with that in blood sampled from the ulnar vein. Thus, blood sampled from the crural varicose veins demonstrated a decrease in the counts of WBC by 9.6% in fourteen (93.3%) patients, that of neutrophils by 4.9% in twelve (80%) patients, that of lymphocytes by 16,8% in fifteen (100%) patients, and that oi monocytes by 24% in twelve (80%) patients. The mentioned differences were statistically significant at a = 0.05. The eosinophilic counts in blood sampled from the upper and lower extremities appeared similar in 66.7% of the examined subjects. In 33.3% of cases the eosinophilic count in blood samples from crural varicose vein was by 16.7% lower than that for blood samples form the ulnar vein. No differences for the rest parameters of the clinical blood count were revealed. The absolute lymphocytic count in the blood samples taken after the 30-minute static loading from the crural varicose veins was significantly lower as compared with that in blood sampled form the cubital vein. The counts for RBCs and blood platelets, as well as other qualitative haematological indices (haemoglobin, haematocrit, average volume of the RBC, erythrocytic diameter, etc.) in blood sampled form crural and ulnar veins in the same patient were identical, thus strongly suggesting the lack of either haemodynamic or haemorheological phenomena capable of leading to redistribution of the blood formed elements in varicose veins. Hence a decrease in the counts of leukocytes and their subpopulations in blood sampled from crural varicose veins might be associated with the «leukocytic trap» phenomenon.
Ignatova, E N; Tupoleva, T A; Ovchinnikova, E N; Romanova, T Yu; Yaroslavtseva, N G; Filatov, F P; Troitskaya, V V; Kuzmina, L A; Parovichnikova, E N; Gaponova, T V; Savchenko, V G
To evaluate the detection rate of markers for hepatitis B virus (HBV) in the blood samples taken from patients with blood system diseases, by applying the current approaches to examining donated blood and its components for markers of viral infections. The investigation included blood samples from patients with blood system diseases (n=364) and donors (n=5,011). The results of laboratory screening of donated blood samples (n=13,081) were retrospectively analyzed. Commercial kits of reagents were used for immunochemical assay and polymerase chain reaction. Patients with blood system diseases were recorded to have markers of active HBV infection in 12.6% of cases, anti-HBc in 31.3%, and anti-HBs in 37.6%. A retrospective analysis of the results of screening donated blood samples showed the presence of markers for active HBV infection in 0.28% of cases. A prospective examination of blood donors revealed markers of HBV infection in 4.83% of cases, including those of active forms in 0.54% and anti-HBc in 4.79%. The markers of active HBV infection in donors were only anti-HBc IgM in 0.42% of cases. The blood samples from donors with an anti-HBs titer of >200 mIU/ml contained anti-HBc IgM in 10.5%. In the last 5-7 years, the detection rate of markers of HBV infection in the blood samples of patients with blood system diseases have remained at a high level. Screening for decreed markers fails to identify people with inapparent infections among the donors. Even high anti-HBs concentrations in the donated blood may be a risk for HBV transmission by transfusion to a recipient.
NHEXAS PHASE I ARIZONA STUDY--METALS IN BLOOD ANALYTICAL RESULTS
The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 165 blood samples over 165 households. Each sample was collected as a venous sample from the primary respondent within each household during Stage III of the NHEXAS study. The samples...
NHEXAS PHASE I MARYLAND STUDY--METALS IN BLOOD ANALYTICAL RESULTS
The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 374 blood samples over 80 households. Each sample was collected via a venous sample from the primary respondent within each household by a phlebotomist. Samples were generally drawn o...
Bedside arterial blood gas monitoring system using fluorescent optical sensors
NASA Astrophysics Data System (ADS)
Bartnik, Daniel J.; Rymut, Russell A.
1995-05-01
We describe a bedside arterial blood gas (ABG) monitoring system which uses fluorescent optical sensors in the measurement of blood pH, PCO2 and PO2. The Point-of-Care Arterial Blood Gas Monitoring System consists of the SensiCathTM optical sensor unit manufactured by Optical Sensors Incorporated and the TramTM Critical Care Monitoring System with ABG Module manufactured by Marquette Electronics Incorporated. Current blood gas measurement techniques require a blood sample to be removed from the patient and transported to an electrochemical analyzer for analysis. The ABG system does not require removal of blood from the patient or transport of the sample. The sensor is added to the patient's existing arterial line. ABG measurements are made by drawing a small blood sample from the arterial line in sufficient quantity to ensure an undiluted sample at the sensor. Measurements of pH, PCO2 and PO2 are made within 60 seconds. The blood is then returned to the patient, the line flushed and results appear on the bedside monitor. The ABG system offers several advantages over traditional electrochemical analyzers. Since the arterial line remains closed during the blood sampling procedure the patient's risk of infection is reduced and the caregiver's exposure to blood is eliminated. The single-use, disposable sensor can be measure 100 blood samples over 72 hours after a single two-point calibration. Quality Assurance checks are also available and provide the caregiver the ability to assess system performance even after the sensor is patient attached. The ABG module integrates with an existing bedside monitoring system. This allows ABG results to appear on the same display as ECG, respiration, blood pressure, cardiac output, SpO2, and other clinical information. The small module takes up little space in the crowded intensive care unit. Performance studies compare the ABG system with an electrochemical blood gas analyzer. Study results demonstrated accurate and precise blood gas measurement of 100 samples and 72 hour performance without need for re-calibration.
Lamming, Christopher E D; Augustin, Lance; Blackstad, Mark; Lund, Troy C; Hebbel, Robert P; Verfaillie, Catherine M
2003-03-01
The only curative therapy for sickle cell disease (SCD) is allogeneic hematopoietic stem cell (HSC) transplantation. Gene therapy approaches for autologous HSC transplantation are being developed. Although earlier engraftment is seen when cells from GCSF-mobilized blood are transplanted than when bone marrow is transplanted, administration of GCSF to patients with SCD can cause significant morbidity. We tested whether primitive hematopoietic progenitors are spontaneously mobilized in the blood of patients with SCD during acute crisis (AC-SCD patients). The frequency of myeloid-lymphoid-initiating cells (ML-ICs) and SCID-repopulating cells (SRCs) was significantly higher in blood from AC-SCD patients than in blood from patients with steady-state SCD or from normal donors. The presence of SRCs in peripheral blood was not associated with detection of long-term culture-initiating cells, consistent with the notion that SRCs are more primitive than long-term culture-initiating cells. As ML-ICs and SRCs were both detected in blood of AC-SCD patients only, these assays may both measure primitive progenitors. The frequency of ML-ICs also correlated with increases in stem cell factor, GCSF, and IL-8 levels in AC-SCD compared with steady-state SCD and normal-donor sera. Because significant numbers of ML-ICs and SRCs are mobilized in the blood without exogenous cytokine treatment during acute crisis of SCD, collection of peripheral blood progenitors during crisis may yield a source of autologous HSCs suitable for ex-vivo correction by gene therapy approaches and subsequent transplantation.
Mintzer, Jonathan P; Parvez, Boriana; La Gamma, Edmund F
2015-11-01
To evaluate the magnitude, consistency, and natural history of reductions in cerebral regional tissue oxygenation (CrSO2) during umbilical arterial (UA) blood sampling in very low birth weight neonates. Data were collected during a prospective observational near-infrared spectroscopy survey conducted on a convenience sample of 500-1250 g neonates during the first 10 postnatal days. A before-after analysis of UA blood sampling effects on CrSO2 absolute values and variability was performed. The present analysis was not designed a priori and was conducted following the bedside observation of CrSO2 decrements contiguous with UA blood draws. Fifteen very low birth weight neonates had 201 UA blood draws. Baseline CrSO2 (mean ± SEM) decreased following UA blood sampling, from 70 ± 1% to a nadir of 63 ± 1% (P < .001) occurring 4 ± 3 (range 2-24) minutes following blood draws. CrSO2 subsequently increased to 70 ± 1% (P < .001 compared with nadir) at 10 ± 4 (range 4-28) minutes following UA blood sampling. Coefficients of variation (mean ± SEM) increased from 0.02 ± 0.001 at baseline to 0.05 ± 0.004 (P < .001), followed by a decrease to 0.03 ± 0.003 (P < .001 for all comparisons), thus denoting increased CrSO2 variability following UA blood sampling. UA blood sampling is associated with significant CrSO2 decrements with increased variability over clinically significant intervals. Whether these changes impact complications of prematurity, including intraventricular hemorrhage and periventricular leukomalacia, remain unknown. Copyright © 2015 Elsevier Inc. All rights reserved.
Humann-Ziehank, Esther; Menzel, Anne; Roehrig, Petra; Schwert, Barbara; Ganter, Martin; Hennig-Pauka, Isabel
2014-10-01
This study was performed to characterise the response of iron (Fe), zinc (Zn), copper (Cu) and selenium (Se) in bacterial-induced porcine acute phase reaction (APR). Twenty piglets were challenged by aerosolic infection with Actinobacillus pleuropneumoniae (A.pp.) serotype 2, ten piglets serving as controls. Blood sampling was done initially and at day 4 and 21 after infection, collection of liver tissue was done at day 21 (autopsy). A.pp.-infection caused fever and respiratory symptoms. APR at day 4 after infection was marked by an increase in total white blood cells, granulocytes and monocytes in whole blood samples and an increase in globulin/albumin ratio (G/A), α2-globulins, C-reactive protein, haptoglobin, ceruloplasmin (Cp), Cu and Se in serum. Concurrently, there was a decrease in haemoglobin (Hb) and packed cell volume (PCV) in whole blood as well as a decrease in albumin, transferrin, total iron binding capacity and Fe in serum and Zn in plasma. The subacute stage at day 21 was characterised by progressively increased concentrations of G/A, β-globulins and γ-globulins reflecting the specific immune reaction. Hb and PCV showed further decreases, all other parameters returned to the initial concentrations. Glutathione peroxidase activity in plasma and liver tissue remained unaffected by A.pp.-infection. The liver concentration (day 21) of Zn was found to be higher, that of Se was lower in the A.pp.-group, whereas hepatic concentrations of Cu and Fe were not affected by A.pp.-infection. In summary, the acute and subacute stages of A.pp.-infection were accurately characterised by the APR-related parameters. Se was only marginally affected by the A.pp.-infection. The elevated plasma Cu concentration may be a side effect of the transient hepatic induction of Cp synthesis. Zn responded, being distinctly reduced in plasma and probably having been sequestered in the liver tissue. Reduction in serum Fe can be regarded as an unspecific defence mechanism in A.pp.-infection to withdraw Fe from bacterial acquisition systems.
Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study
Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung
2016-01-01
Background To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. Objective In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. Methods We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants’ opinions regarding patient safety, timeliness, efficiency, and usability were recorded. Results In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its timeliness, and did not believe that it was efficient. Although the bar code scanning speed was acceptable, the Wi-Fi environment required improvement. Moreover, the participants requested feedback regarding their sampling quality. Conclusions Although this app could be used in the clinical setting, improvements in the app functions, environment network, and internal policy of blood culture testing are needed to ensure hospital-wide use. PMID:27784649
Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study.
Lee, Guna; Lee, Yura; Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung; Lee, Jae-Ho
2016-10-26
To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants' opinions regarding patient safety, timeliness, efficiency, and usability were recorded. In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its timeliness, and did not believe that it was efficient. Although the bar code scanning speed was acceptable, the Wi-Fi environment required improvement. Moreover, the participants requested feedback regarding their sampling quality. Although this app could be used in the clinical setting, improvements in the app functions, environment network, and internal policy of blood culture testing are needed to ensure hospital-wide use.
2013-01-01
Background Genotyping requires biological sample collection that must be reliable, convenient and acceptable for patients and clinicians. Finding the most optimal procedure of sample collection for premature neonates who have a very limited blood volume is a particular challenge. The aim of the current study was to evaluate the use of umbilical cord (UC) tissue and newborn dried blood spot (DBS)-extracted genomic DNA (gDNA) as an alternative to venous blood-derived gDNA from premature neonates for molecular genetic analysis. All samples were obtained from premature newborn infants between 24-32 weeks of gestation. Paired blood and UC samples were collected from 31 study participants. gDNA was extracted from ethylenediaminetetraacetic acid (EDTA) anticoagulant-treated blood samples (~500 μl) and newborn DBSs (n = 723) using QIAamp DNA Micro kit (Qiagen Ltd., Crawley, UK); and from UC using Qiagen DNAeasy Blood and Tissue kit (Qiagen Ltd., Crawley, UK). gDNA was quantified and purity confirmed by measuring the A260:A280 ratio. PCR amplification and pyrosequencing was carried out to determine suitability of the gDNA for molecular genetic analysis. Minor allele frequency of two unrelated single nucleotide polymorphisms (SNPs) was calculated using the entire cohort. Results Both whole blood samples and UC tissue provided good quality and yield of gDNA, which was considerably less from newborn DBS. The gDNA purity was also reduced after 3 years of storage of the newborn DBS. PCR amplification of three unrelated genes resulted in clear products in all whole blood and UC samples and 86%-100% of newborn DBS. Genotyping using pyrosequencing showed 100% concordance in the paired UC and whole blood samples. Minor allele frequencies of the two SNPs indicated that no maternal gDNA contamination occurred in the genotyping of the UC samples. Conclusions gDNAs from all three sources are suitable for standard PCR and pyrosequencing assays. Given that UC provide good quality and quantity gDNA with 100% concordance in the genetic analysis with whole blood, it can replace blood sampling from premature infants. This is likely to reduce the stress and potential side effects associated with invasive sample collection and thus, greatly facilitate participant recruitment for genetic studies. PMID:24168095
Komech, Ekaterina A; Pogorelyy, Mikhail V; Egorov, Evgeniy S; Britanova, Olga V; Rebrikov, Denis V; Bochkova, Anna G; Shmidt, Evgeniya I; Shostak, Nadejda A; Shugay, Mikhail; Lukyanov, Sergey; Mamedov, Ilgar Z; Lebedev, Yuriy B; Chudakov, Dmitriy M; Zvyagin, Ivan V
2018-02-22
The risk of AS is associated with genomic variants related to antigen presentation and specific cytokine signalling pathways, suggesting the involvement of cellular immunity in disease initiation/progression. The aim of the present study was to explore the repertoire of TCR sequences in healthy donors and AS patients to uncover AS-linked TCR variants. Using quantitative molecular-barcoded 5'-RACE, we performed deep TCR β repertoire profiling of peripheral blood (PB) and SF samples for 25 AS patients and 108 healthy donors. AS-linked TCR variants were identified using a new computational approach that relies on a probabilistic model of the VDJ rearrangement process. Using the donor-agnostic probabilistic model, we reveal a TCR β motif characteristic for PB of AS patients, represented by eight highly homologous amino acid sequence variants. Some of these variants were previously reported in SF and PB of patients with ReA and in PB of AS patients. We demonstrate that identified AS-linked clones have a CD8+ phenotype, present at relatively low frequencies in PB, and are significantly enriched in matched SF samples of AS patients. Our results suggest the involvement of a particular antigen-specific subset of CD8+ T cells in AS pathogenesis, confirming and expanding earlier findings. The high similarity of the clonotypes with the ones found in ReA implies common mechanisms for the initiation of the diseases.
Milman, Nils; Koefoed, Pernille; Pedersen, Palle; Nielsen, Finn Cilius; Eiberg, Hans
2003-12-01
To assess the frequency of the C282Y and H63D mutations on the HFE gene in Danish patients with clinical hereditary haemochromatosis initially diagnosed by phenotypic methods. In the period 1950-1985, an epidemiological survey in Denmark identified 179 patients with clinical idiopathic haemochromatosis diagnosed by phenotypic methods (serum transferrin saturation, serum ferritin, liver biopsy and mobilisable body iron stores). In 32 unrelated patients, frozen blood samples were available for genetic analysis. In a subsequent series of 26 unrelated Danish patients, a phenotypic diagnosis of clinical idiopathic haemochromatosis was made before blood samples were taken for HFE genotyping. The total series consisted of 58 patients (40 men and 18 women) with a median age of 60 yrs (range 18-74). HFE genotyping was performed by the polymerase chain reaction (PCR) technique. Among the patients, 55 of 58 (94.8%) were C282Y/C282Y homozygous. One 63-year-old woman (1.7%) was compound C282Y/H63D heterozygous. Two women (3.4%), aged 42 and 43 yrs were negative for both the C282Y and the H63D mutation. In the Danish population, homozygosity for the C282Y mutation appears to be the prevailing cause of clinically overt genetic haemochromatosis. This finding has implications both for the evaluation of patients with iron overload disorders and for the strategy in future population screening surveys.
Smith, Alan D
2011-01-01
A general overview of various blood products operational effectiveness and related strategies that can be utilised by service providers (in particular, healthcare providers) is presented in the present study. In terms of the massive volumes of blood products, the North American blood centres collect more than eight million units of whole blood, which represents appropriately 50% of the US and Quebec, Canada?s volunteer donor blood supply. A case study of the quality inspection and inventory control concerns of the Central Blood Bank, located in the metropolitan area of Pittsburgh, PA, is presented. Initially, brief introduction to its general operating environment is followed by sections describing its general situation, quality-service initiatives, and followed by a fairly detailed discussion of the practical applications of lessons learned from the case study.
He, Lixian; Zhao, Su; Weng, Heng; Yang, Guowang
2015-01-01
This pilot study assesses the safety and efficacy of once-daily, oral levofloxacin monotherapy in Chinese patients with low-risk febrile neutropenia. In this prospective, single-arm, open-label, multicenter clinical trial, 46 adult Chinese patients with solid tumors and low-risk febrile neutropenia were included. Patients received oral levofloxacin monotherapy (500 mg orally/day) until day 12, followed by 7 days of follow-up (day 19). Body temperature was measured three times per day. On days 2, 3, 5–7, 9, 12, and 19, disease symptoms and vital signs were recorded, adverse drug reactions were assessed, and blood samples were collected to determine the whole-blood cell count and the absolute neutrophil count. Blood cultures and chest radiographs were performed simultaneously until negative results were found. Oral levofloxacin was effective and well tolerated in 97.6% of patients irrespective of the cancer type and cause of fever. Body temperature began to decline in 24.4, 68.3, and 90.2% of patients, respectively, at 12, 24, and 48 h after initiating levofloxacin therapy. On days 5 and 7, 95.1 and 97.6% of the patients had complete defervescence, respectively. The median time for absolute neutrophil count recovery to at least 1500/mm3 after initiation of treatment was 3 days. Only one patient reported mild diarrhea. This pilot study showed that oral levofloxacin quickly and effectively reduced fever, initiated neutrophil recovery, and was well tolerated in Chinese low-risk febrile neutropenic patients with solid tumors. Further study is needed to compare patient data of levofloxacin with the standard amoxicillin/ciprofloxacin protocol in this population for both safety and efficacy. PMID:25486597
The next chapter in patient blood management: real-time clinical decision support.
Goodnough, Lawrence Tim; Shah, Neil
2014-12-01
Blood transfusion was identified by the American Medical Association as one of the top five most frequently overused therapies. Utilization review has been required by accreditation agencies, but retrospective review has been ineffective due to labor-intense resources applied to only a sampling of transfusion events. Electronic medical records have allowed clinical decision support (CDS) to occur via a best practices alert at the critical decision point concurrently with physician order entry. We review emerging strategies for improving blood utilization. Implementation of CDS at our institution decreased the percentage of transfusions in patients with a hemoglobin level of more than 8 g/dL from 60% to less than 30%. Annual RBC transfusions were reduced by 24%, despite concurrent increases in patient discharge volumes and case mix complexity. This resulted in acquisition costs savings (direct blood product purchase costs) of $6.4 million over 4 years. We have been able to significantly reduce inappropriate blood transfusions and related costs through an educational initiative coupled with real-time CDS. In deriving increased value out of health care, CDS can be applied to a number of overuse measures in laboratory testing, radiology, and therapy such as antibiotics, as outlined by the American Board of Internal Medicine's Choosing Wisely campaign. Copyright© by the American Society for Clinical Pathology.
Real-time PCR detection of Plasmodium directly from whole blood and filter paper samples
2011-01-01
Background Real-time PCR is a sensitive and specific method for the analysis of Plasmodium DNA. However, prior purification of genomic DNA from blood is necessary since PCR inhibitors and quenching of fluorophores from blood prevent efficient amplification and detection of PCR products. Methods Reagents designed to specifically overcome PCR inhibition and quenching of fluorescence were evaluated for real-time PCR amplification of Plasmodium DNA directly from blood. Whole blood from clinical samples and dried blood spots collected in the field in Colombia were tested. Results Amplification and fluorescence detection by real-time PCR were optimal with 40× SYBR® Green dye and 5% blood volume in the PCR reaction. Plasmodium DNA was detected directly from both whole blood and dried blood spots from clinical samples. The sensitivity and specificity ranged from 93-100% compared with PCR performed on purified Plasmodium DNA. Conclusions The methodology described facilitates high-throughput testing of blood samples collected in the field by fluorescence-based real-time PCR. This method can be applied to a broad range of clinical studies with the advantages of immediate sample testing, lower experimental costs and time-savings. PMID:21851640
Blood oxygen saturation determined by transmission spectrophotometry of hemolyzed blood samples
NASA Technical Reports Server (NTRS)
Malik, W. M.
1967-01-01
Use of the Lambert-Beer Transmission Law determines blood oxygen saturation of hemolyzed blood samples. This simplified method is based on the difference in optical absorption properties of hemoglobin and oxyhemoglobin.
A rapid, highly sensitive and culture-free detection of pathogens from blood by positive enrichment.
Vutukuru, Manjula Ramya; Sharma, Divya Khandige; Ragavendar, M S; Schmolke, Susanne; Huang, Yiwei; Gumbrecht, Walter; Mitra, Nivedita
2016-12-01
Molecular diagnostics is a promising alternative to culture based methods for the detection of bloodstream infections, notably due to its overall lower turnaround time when starting directly from patient samples. Whole blood is usually the starting diagnostic sample in suspected bloodstream infections. The detection of low concentrations of pathogens in blood using a molecular assay necessitates a fairly high starting volume of blood sample in the range of 5-10mL. This large volume of blood sample has a substantial accompanying human genomic content that interferes with pathogen detection. In this study, we have established a workflow using magnetic beads coated with Apolipoprotein H that makes it possible to concentrate pathogens from a 5.0mL whole blood sample, thereby enriching pathogens from whole blood background and also reducing the sample volume to ~200μL or less. We have also demonstrated that this method of enrichment allows detection of 1CFU/mL of Escherichia coli, Enterococcus gallinarum and Candida tropicalis from 5mL blood using quantitative PCR; a detection limit that is not possible in unenriched samples. The enrichment method demonstrated here took 30min to complete and can be easily integrated with various downstream molecular and microbiological techniques. Copyright © 2016 Elsevier B.V. All rights reserved.
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN BLOOD ANALYTICAL RESULTS
The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 86 blood samples over 86 households. Each sample was collected as a venous sample from the primary respondent within each household. The samples consisted of two 3-mL tubes. The prim...
[Identification of Animal Whole Blood Based on Near Infrared Transmission Spectroscopy].
Wan, Xiong; Wang, Jian; Liu, Peng-xi; Zhang, Ting-ting
2016-01-01
The inspection and classification for blood products are important but complicated in import-export ports or inspection and quarantine departments. For the inspection of whole blood products, open sampling can cause pollution and virulence factors in bloods samples may even endanger inspectors. Thus non-contact classification and identification methods for whole bloods of animals are needed. Spectroscopic techniques adopted in the flowcytometry need sampling blood cells during the detection; therefore they can not meet the demand of non-contact identification and classification for whole bloods of animals. Infrared absorption spectroscopy is a technique that can be used to analyze the molecular structure and chemical bonds of detected samples under the condition of non-contact. To find a feasible spectroscopic approach of non-contact detection for the species variation in whole blood samples, a near infrared transmitted spectra (NITS, 4 497.669 - 7 506.4 cm(-1)) experiment of whole blood samples of three common animals including chickens, dogs and cats has been conducted. During the experiment, the spectroscopic resolution is 5 cm(-1), and each spectrogram is an average of 5 measured spectral data. Experimental results show that all samples have a sharp absorption peak between 5 184 and 5 215 cm(-1), and a gentle absorption peak near 7 000 cm(-1). Besides, the NITS curves of different samples of same animals are similar, and only have slight differences in the whole transmittance. A correlation coefficient (CC) is induced to distinguish the differences of the three animals' whole bloods in NITS curves, and the computed CCs between NITS curves of different samples of the same animals, are greater than 0.99, whereas CCs between NITS curves of the whole bloods of different animals are from 0.509 48 to 0.916 13. Among which CCs between NITS curves of the whole bloods of chickens and cats are from 0.857 23 to 0.912 44, CCs between NITS curves of the whole bloods of chickens and dogs are from 0.509 48 to 0.664 82, and CCs between NITS curves of the whole bloods of cats and dogs are from 0.872 75 to 0.916 13. The cat and the dog belong to the class of mammal, and the CCs between their whole bloods NITS curves are greater than those between chickens and cats, or chickens and dogs, which are hetero-class animals. Namely, the whole bloods NITS curves of the cat and the dog have higher similarity. These results of NITS provide a feasible method of non-contact identification of animal whole bloods.
San Martín, Héctor; Balanda, Monserrat; Vergara, Nicolás; Valenzuela, María Antonieta; Cartier, Luis; Ayala, Salvador; Ramírez, Eugenio
2016-06-01
Infection with human T-lymphotropic virus type 1/2 (HTLV-1/2) is a major health problem. HTLV-1/2 infection is endemic in Chile but representative donor prevalence data are lacking. Data on all blood donors in a large network of Chilean blood centers were examined during 2011-2013. Screening of HTLV-1/2 antibodies were measured by enzyme immunoassay (EIA) at all blood banks. Blood samples with anticoagulants from initially reactive blood donors were analyzed by serological confirmation tests (immunofluorescence or recombinant immunoblot) at the HTLV National Reference Laboratory of the Public Health Institute of Chile. Additionally, detection of HTLV-1 and HTLV-2 provirus in peripheral blood mononuclear cells (PBMCs) was performed in all blood donors as confirmatory test. Prevalence rates were calculated. Among 694,016 donors, 706 were seropositive for HTLV-1 (prevalence, 1.02 cases per 1,000; 95% confidence interval [CI], 0.94-1.09), and 97 were seropositive for HTLV-2 (prevalence, 0.14 cases per 1,000; 95%CI, 0.11-0.17). Prevalence of HTLV-1 differed considerably by region, from 0.51 to 1.69 per 1,000. Prevalence of HTLV-2 was similar across the country (0.12-0.16). HTLV-1 prevalence was associated with female sex, older age, and residence in the north of Chile. HTVL-2 prevalence was associated with older age. The HTLV-1 prevalence among Chilean blood donors was relatively high and could be reduced by improving donor recruitment and selection in high prevalence areas. Blood center data may contribute to surveillance for HTLV-1 and HTLV-2 infections. © 2015 Wiley Periodicals, Inc.
Westenbrink, W
1992-01-01
Police officers can now demand blood samples from suspected impaired drivers in Canada to determine their Blood Alcohol Concentration. The medical laboratory technologist has been given the authority to take blood samples for legal purposes, as well as the authorization to complete certificates used as evidence in court. The proper procedures for the taking of blood samples and the completion of certificates are described in detail. The Criminal Code offences dealing with drinking and driving, the means by which police officers can legally obtain blood samples, the Blood Alcohol Kit, and the provision of providing blood collection evidence in court are discussed to aid the technologists in understanding their role in this process. The Criminal Code definitions of a "qualified medical practitioner", a "qualified technician", and "approved containers" are also described.
Congleton, J.L.; LaVoie, W.J.
2001-01-01
Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.
NHEXAS PHASE I REGION 5 STUDY--METALS IN BLOOD ANALYTICAL RESULTS
This data set includes analytical results for measurements of metals in 165 blood samples. These samples were collected to examine the relationships between personal exposure measurements, environmental measurements, and body burden. Venous blood samples were collected by venipun...
NHEXAS PHASE I REGION 5 STUDY--VOCS IN BLOOD ANALYTICAL RESULTS
This data set includes analytical results for measurements of VOCs (volatile organic compounds) in 145 blood samples. These samples were collected to examine the relationships between personal exposure measurements, environmental measurements, and body burden. Venous blood sample...
Hashairi, F; Hasan, H; Azlan, K; Deris, Z Z
2011-12-01
An understanding of common pathogens and their antibiotic sensitivity patterns is critical for proper management of sepsis in Emergency Department (ED). The goal of the study was to identify common organisms isolated from blood cultures of patients attended to ED and their antimicrobial susceptibility. Beginning from 2002, all cases of positive blood culture collected by the ED, Hospital Universiti Sains Malaysia (HUSM) were recorded and analysed. Over the period of eight years, we documented 995 cases of positive blood cultures. Of these samples, 549 (55.2%) were Gram-negative bacteria; 419 (42.1%) were Gram-positive bacteria; 10 (1.0%) were anaerobic organisms; 10 (1.0%) were fungus; and 7 (0.7%) cases were mixed organisms. Gram-negative bacteria were observed to develop more resistance to antimicrobial agents, especially those commonly used in an outpatient setting with less than 80% sensitivity to ampicillin, cotrimoxazole and ciprofloxacin. By contrast, there has been no marked change in the sensitivity trends of Gram-positive bacteria over the same period. In conclusion, ED physicians are more equipped to initiate empirical antimicrobial therapy especially when dealing with possibility of Gram-negative sepsis.
Mosher, Ruby A; Coetzee, Johann F; Allen, Portia S; Havel, James A; Griffith, Gary R; Wang, Chong
2014-02-01
To determine the effects of protease inhibitors and holding times and temperatures before processing on the stability of substance P in bovine blood samples. Blood samples obtained from a healthy 6-month-old calf. Blood samples were dispensed into tubes containing exogenous substance P and 1 of 6 degradative enzyme inhibitor treatments: heparin, EDTA, EDTA with 1 of 2 concentrations of aprotinin, or EDTA with 1 of 2 concentrations of a commercially available protease inhibitor cocktail. Plasma was harvested immediately following collection or after 1, 3, 6, 12, or 24 hours of holding at ambient (20.3° to 25.4°C) or ice bath temperatures. Total substance P immunoreactivity was determined with an ELISA; concentrations of the substance P parent molecule, a metabolite composed of the 9 terminal amino acids, and a metabolite composed of the 5 terminal amino acids were determined with liquid chromatography-tandem mass spectrometry. Regarding blood samples processed immediately, no significant differences in substance P concentrations or immunoreactivity were detected among enzyme inhibitor treatments. In blood samples processed at 1 hour of holding, substance P parent molecule concentration was significantly lower for ambient temperature versus ice bath temperature holding conditions; aprotinin was the most effective inhibitor of substance P degradation at the ice bath temperature. The ELISA substance P immunoreactivity was typically lower for blood samples with heparin versus samples with other inhibitors processed at 1 hour of holding in either temperature condition. Results suggested that blood samples should be chilled and plasma harvested within 1 hour after collection to prevent substance P degradation.
Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine
2010-09-01
Scand J Caring Sci; 2010; 24; 581-591 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory. To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories. Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing. The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff. The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.
Young, L A; Schumacher, J; Papich, M G; Jacobson, E R
1997-03-01
Eleven juvenile Burmese pythons (Python molurus bivittatus) weighing 0.75-1.75 kg were randomly divided into two groups. Blood samples were obtained through surgically placed anterior carotid artery cannulas. Six pythons received a single i.m. injection of enrofloxacin at 5 mg/kg. Blood samples were obtained at 0.5, 1, 3, 6, 12, 24, 48, 72, and 96 hr postinjection. A mean (+/- SD) maximal plasma concentration of 1.66 (+/- 0.42) micrograms/ml was measured at 5.75 hr postinjection. The harmonic mean half-life was calculated to be 6.37 hr. The second group of five snakes received enrofloxacin at 5 mg/kg i.m. s.i.d. for 5 days. Blood was collected immediately before each injection and at 6 hr after each injection. Over the 5-day period, there was a stepwise increase in mean trough plasma concentrations of enrofloxacin. Clinically effective peak plasma enrofloxacin concentrations were attained after the first injection but did not significantly increase during the sampling period. Pharmacokinetic data were assessed against minimum inhibitory concentrations of enrofloxacin for Pseudomonas ssp. isolates in snakes obtained from historical data at the Veterinary Medical Teaching Hospital, University of Florida. Enrofloxacin should be administered at 10 mg/kg i.m. every 48 hr when treating Pseudomonas ssp. infections in juvenile Burmese pythons. Treatment of infections of more enrofloxacin-sensitive gram-negative bacteria could be achieved with the administration of an initial i.m. dose of 10 mg/kg followed by 5 mg/kg every 48 hr.
Donahoe, Shannon L.; Peacock, Christopher S.; Choo, Ace Y.L.; Cook, Roger W.; O'Donoghue, Peter; Crameri, Sandra; Vogelnest, Larry; Gordon, Anita N.; Scott, Jenni L.; Rose, Karrie
2015-01-01
This is a retrospective study of 38 cases of infection by Babesia macropus, associated with a syndrome of anaemia and debility in hand-reared or free-ranging juvenile eastern grey kangaroos (Macropus giganteus) from coastal New South Wales and south-eastern Queensland between 1995 and 2013. Infection with B. macropus is recorded for the first time in agile wallabies (Macropus agilis) from far north Queensland. Animals in which B. macropus infection was considered to be the primary cause of morbidity had marked anaemia, lethargy and neurological signs, and often died. In these cases, parasitised erythrocytes were few or undetectable in peripheral blood samples but were sequestered in large numbers within small vessels of visceral organs, particularly in the kidney and brain, associated with distinctive clusters of extraerythrocytic organisms. Initial identification of this piroplasm in peripheral blood smears and in tissue impression smears and histological sections was confirmed using transmission electron microscopy and molecular analysis. Samples of kidney, brain or blood were tested using PCR and DNA sequencing of the 18S ribosomal RNA and heat shock protein 70 gene using primers specific for piroplasms. The piroplasm detected in these samples had 100% sequence identity in the 18S rRNA region with the recently described Babesia macropus in two eastern grey kangaroos from New South Wales and Queensland, and a high degree of similarity to an unnamed Babesia sp. recently detected in three woylies (Bettongia penicillata ogilbyi) in Western Australia. PMID:26106576
Donahoe, Shannon L; Peacock, Christopher S; Choo, Ace Y L; Cook, Roger W; O'Donoghue, Peter; Crameri, Sandra; Vogelnest, Larry; Gordon, Anita N; Scott, Jenni L; Rose, Karrie
2015-08-01
This is a retrospective study of 38 cases of infection by Babesia macropus, associated with a syndrome of anaemia and debility in hand-reared or free-ranging juvenile eastern grey kangaroos (Macropus giganteus) from coastal New South Wales and south-eastern Queensland between 1995 and 2013. Infection with B. macropus is recorded for the first time in agile wallabies (Macropus agilis) from far north Queensland. Animals in which B. macropus infection was considered to be the primary cause of morbidity had marked anaemia, lethargy and neurological signs, and often died. In these cases, parasitised erythrocytes were few or undetectable in peripheral blood samples but were sequestered in large numbers within small vessels of visceral organs, particularly in the kidney and brain, associated with distinctive clusters of extraerythrocytic organisms. Initial identification of this piroplasm in peripheral blood smears and in tissue impression smears and histological sections was confirmed using transmission electron microscopy and molecular analysis. Samples of kidney, brain or blood were tested using PCR and DNA sequencing of the 18S ribosomal RNA and heat shock protein 70 gene using primers specific for piroplasms. The piroplasm detected in these samples had 100% sequence identity in the 18S rRNA region with the recently described Babesia macropus in two eastern grey kangaroos from New South Wales and Queensland, and a high degree of similarity to an unnamed Babesia sp. recently detected in three woylies (Bettongia penicillata ogilbyi) in Western Australia.
Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew
2007-01-01
The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.
Xue, Hui; Ix, Joachim H.; Wang, Weiling; Brunelli, Steven M.; Lazarus, Michael; Hakim, Raymond; Lacson, Eduardo
2012-01-01
Background Hemodialysis(HD) access is considered a critical and actionable determinant of morbidity, with a growing literature suggesting that initial HD access type is an important marker of long term outcomes. Accordingly, we examined HD access during the incident dialysis period, focusing on infection risk and successful fistula creation over the first dialysis year. Study Design Longitudinal cohort Setting & Participants All United States adults admitted to Fresenius Medical Care North America facilities within 15 days of first maintenance dialysis session between January 1 and December 31, 2007. Predictor Vascular access type at HD initiation Outcomes Vascular access type at 90 days and at the end of the first year on HD, bloodstream infection within the first year by access type, and catheter complication rate. Results Amongst the 25,003 incident dialysis patients studied, 19,622(78.5%) initiated dialysis with a catheter, 4,151(16.6%) with a fistula, and 1,230(4.9%) with a graft. At 90 days, 14,105(69.7%) had a catheter, 4432(21.9%) patients had a fistula, and 1705(8.4%) had a graft. Functioning fistulas and grafts at dialysis initiation had first year failure rates of 10% and 15%, respectively. Grafts were seldom replaced by fistulas (3%), while 7,064 (47.6%) of all patients who initiated with a catheter alone still had only a catheter at 1 year. Overall, 3,327 (13.3%) patients had at least one positive blood culture during follow-up, with the risk being similar between fistula and graft groups, but approximately 3-fold higher in patients with a catheter (p<0.001 for either comparison). Nearly one in three catheters (32.5%) will require TPA use by median time of 41 days, with 59% requiring more than one TPA administration. Limitations Potential underestimation of bacteremia because follow-up blood culture results did not include samples sent to local laboratories. Conclusions Among a large and representative population of incident US dialysis patients, catheter use remains very high over the first year of hemodialysis care, and is associated with high mechanical complication and blood stream infection rates. PMID:23159234
Compression and flexural strength of bone cement mixed with blood.
Tan, J H; Koh, B Th; Ramruttun, A K; Wang, W
2016-08-01
To assess the compression and flexural strength of bone cement mixed with 0 ml, 1 ml, or 2 ml of blood. High viscosity polymethyl methacrylate (PMMA) loaded with or without gentamicin was used. Blood was collected from total knee arthroplasty patients. In the same operating room, one pack of cement each was mixed with 0 ml (control), 1 ml, or 2 ml of blood for 1 minute during the dough phase. The dough was extruded into cylindrical and rectangular moulds for 20 minutes of setting, and then cured in phosphate buffered saline at 37±1ºC for 7 days. The samples were visually inspected for fractures and areas of weakness, and then scanned using microcomputed tomography. 48 gentamicin-loaded and 59 non-gentamicin-loaded samples mixed with 0 ml (control), 1 ml, or 2 ml of blood were randomised for flexural and compression strength testing; each group had at least 6 samples. In samples loaded with or without gentamicin, the flexural and compressive strength was highest in controls, followed by samples mixed with 1 ml or 2 ml of blood. In samples mixed with 2 ml of blood, the flexural strength fell below the standard of 50 MPa. In samples mixed with 2 ml of blood and all gentamicin-loaded samples, the compressive strength fell below the standard of 70 MPa. Microcomputed tomography revealed areas of voids and pores indicating the presence of laminations and partitions within. The biomechanical strength of PMMA contaminated with blood may decrease. Precautions such as saline lavage, pack drying the bone, change of gloves, and prompt insertion of the implant should be taken to prevent blood from contaminating bone cement.
Integrated Blood Barcode Chips
Fan, Rong; Vermesh, Ophir; Srivastava, Alok; Yen, Brian K.H.; Qin, Lidong; Ahmad, Habib; Kwong, Gabriel A.; Liu, Chao-Chao; Gould, Juliane; Hood, Leroy; Heath, James R.
2008-01-01
Blood comprises the largest version of the human proteome1. Changes of plasma protein profiles can reflect physiological or pathological conditions associated with many human diseases, making blood the most important fluid for clinical diagnostics2-4. Nevertheless, only a handful of plasma proteins are utilized in routine clinical tests. This is due to a host of reasons, including the intrinsic complexity of the plasma proteome1, the heterogeneity of human diseases and the fast kinetics associated with protein degradation in sampled blood5. Simple technologies that can sensitively sample large numbers of proteins over broad concentration ranges, from small amounts of blood, and within minutes of sample collection, would assist in solving these problems. Herein, we report on an integrated microfluidic system, called the Integrated Blood Barcode Chip (IBBC). It enables on-chip blood separation and the rapid measurement of a panel of plasma proteins from small quantities of blood samples including a fingerprick of whole blood. This platform holds potential for inexpensive, non-invasive, and informative clinical diagnoses, particularly, for point-of-care. PMID:19029914
Lu, Jun; Li, Li-Ming; He, Ping-Ping; Cao, Wei-Hua; Zhan, Si-Yan; Hu, Yong-Hua
2004-06-01
To introduce the application of mixed linear model in the analysis of secular trend of blood pressure under antihypertensive treatment. A community-based postmarketing surveillance of benazepril was conducted in 1831 essential hypertensive patients (age range from 35 to 88 years) in Shanghai. Data of blood pressure was analyzed every 3 months with mixed linear model to describe the secular trend of blood pressure and changes of age-specific and gender-specific. The changing trends of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were found to fit the curvilinear models. A piecewise model was fit for pulse pressure (PP), i.e., curvilinear model in the first 9 months and linear model after 9 months of taking medication. Both blood pressure and its velocity gradually slowed down. There were significant variation for the curve parameters of intercept, slope, and acceleration. Blood pressure in patients with higher initial levels was persistently declining in the 3-year-treatment. However blood pressures of patients with relatively low initial levels remained low when dropped down to some degree. Elderly patients showed high SBP but low DBP, so as with higher PP. The velocity and sizes of blood pressure reductions increased with the initial level of blood pressure. Mixed linear model is flexible and robust when applied to the analysis of longitudinal data but with missing values and can also make the maximum use of available information.
NASA Astrophysics Data System (ADS)
Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.
2016-05-01
Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.
Whole blood analysis rotor assembly having removable cellular sedimentation bowl
Burtis, C.A.; Johnson, W.F.
1975-08-26
A rotor assembly for performing photometric analyses using whole blood samples is described. Following static loading of a gross blood sample within a centrally located, removable, cell sedimentation bowl, the red blood cells in the gross sample are centrifugally separated from the plasma, the plasm displaced from the sedimentation bowl, and measured subvolumes of plasma distributed to respective sample analysis cuvettes positioned in an annular array about the rotor periphery. Means for adding reagents to the respective cuvettes are also described. (auth)
Association of δ13C in Fingerstick Blood with Added Sugars and Sugar-sweetened Beverage Intake
Davy, Brenda M.; Jahren, A. Hope; Hedrick, Valisa E.; Comber, Dana L.
2011-01-01
A reliance on self-reported dietary intake measures is a common research limitation, thus the need for dietary biomarkers. Added sugar intake may play a role in the development and progression of obesity and related co-morbidities; common sweeteners include corn and sugar cane derivatives. These plants contain a high amount of 13C, a naturally-occurring stable carbon isotope. Consumption of these sweeteners, of which sugar-sweetened beverages (SSB) are the primary dietary source, may be reflected in the δ13C value of blood. Fingerstick blood represents an ideal substrate for bioassay due to its ease of acquisition. The objective of this investigation was to determine if the δ13C value of fingerstick blood is a potential biomarker of added sugar and SSB intake. Individuals aged ≥21 years (n=60) were recruited to attend three laboratory visits; assessments completed at each visit depended upon a randomly assigned sequence (sequence one or two). The initial visit included assessment of height, weight, and dietary intake (sequence one: beverage intake questionnaire [BEVQ], sequence two: four-day food intake record [FIR]). Sequence one participants completed an FIR at visit two, and non-fasting blood samples were obtained via routine finger sticks at visits one and three. Sequence two participants completed a BEVQ at visit two, and provided fingerstick blood samples at visits two and three. Samples were analyzed for δ13C value using natural abundance stable isotope mass spectrometry. δ13C value was compared to dietary outcomes in all participants, as well as among those in the highest and lowest tertile of added sugar intake. Reported mean added sugar consumption was 66±5g/day, and SSB consumption was 330±53g/day and 134±25 kcal/day. Mean fingerstick δ13C value was −19.94±0.10‰, which differed by BMI status. δ13C value was associated (all p<0.05) with intake of total added sugars (g, r=0.37; kcal, r=0.37), soft drinks (g, r=0.26; kcal, r=0.27), and total SSB (g, r=0.28; kcal, r=0.35). The δ13C value in the lowest and the highest added sugar intake tertiles were significantly different (mean difference = −0.48‰, p=0.028). Even though there are several potential dietary sources for blood carbon, the δ13C value of fingerstick blood shows promise as a non-invasive biomarker of added sugar and SSB intake based on these findings. PMID:21616200
Mechanisms of red blood cells agglutination in antibody-treated paper.
Jarujamrus, Purim; Tian, Junfei; Li, Xu; Siripinyanond, Atitaya; Shiowatana, Juwadee; Shen, Wei
2012-05-07
Recent reports on using bio-active paper and bio-active thread to determine human blood type have shown a tremendous potential of using these low-cost materials to build bio-sensors for blood diagnosis. In this work we focus on understanding the mechanisms of red blood cell agglutination in the antibody-loaded paper. We semi-quantitatively evaluate the percentage of antibody molecules that are adsorbed on cellulose fibres and can potentially immobilize red blood cells on the fibre surface, and the percentage of the molecules that can desorb from the cellulose fibre surface into the blood sample and cause haemagglutination reaction in the bulk of a blood sample. Our results show that 34 to 42% of antibody molecules in the papers treated with commercial blood grouping antibodies can desorb from the fibre surface. When specific antibody molecules are released into the blood sample via desorption, haemagglutination reaction occurs in the blood sample. The reaction bridges the red cells in the blood sample bulk to the layer of red cells immobilized on the fibre surface by the adsorbed antibody molecules. The desorbed antibody also causes agglutinated lumps of red blood cells to form. These lumps cannot pass through the pores of the filter paper. The immobilization and filtration of agglutinated red cells give reproducible identification of positive haemagglutination reaction. Results from this study provide information for designing new bio-active paper-based devices for human blood typing with improved sensitivity and specificity.
Zakaria, Rosita; Allen, Katrina J; Koplin, Jennifer J; Roche, Peter; Greaves, Ronda F
2016-12-01
Through the introduction of advanced analytical techniques and improved throughput, the scope of dried blood spot testing utilising mass spectrometric methods, has broadly expanded. Clinicians and researchers have become very enthusiastic about the potential applications of dried blood spot based mass spectrometric applications. Analysts on the other hand face challenges of sensitivity, reproducibility and overall accuracy of dried blood spot quantification. In this review, we aim to bring together these two facets to discuss the advantages and current challenges of non-newborn screening applications of dried blood spot quantification by mass spectrometry. To address these aims we performed a key word search of the PubMed and MEDLINE online databases in conjunction with individual manual searches to gather information. Keywords for the initial search included; "blood spot" and "mass spectrometry"; while excluding "newborn"; and "neonate". In addition, databases were restricted to English language and human specific. There was no time period limit applied. As a result of these selection criteria, 194 references were identified for review. For presentation, this information is divided into: 1) clinical applications; and 2) analytical considerations across the total testing process; being pre-analytical, analytical and post-analytical considerations. DBS analysis using MS applications is now broadly applied, with drug monitoring for both therapeutic and toxicological analysis being the most extensively reported. Several parameters can affect the accuracy of DBS measurement and further bridge experiments are required to develop adjustment rules for comparability between dried blood spot measures and the equivalent serum/plasma values. Likewise, the establishment of independent reference intervals for dried blood spot sample matrix is required.
NASA Astrophysics Data System (ADS)
Marguí, E.; Queralt, I.; García-Ruiz, E.; García-González, E.; Rello, L.; Resano, M.
2018-01-01
Home-based collection protocols for clinical specimens are actively pursued as a means of improving life quality of patients. In this sense, dried blood spots (DBS) are proposed as a non-invasive and even self-administered alternative to sampling whole venous blood. This contribution explores the potential of energy dispersive X-ray fluorescence spectrometry for the simultaneous and direct determination of some major (S, Cl, K, Na), minor (P, Fe) and trace (Ca, Cu, Zn) elements in blood, after its deposition onto clinical filter papers, thus giving rise to DBS. For quantification purposes the best strategy was to use matrix-matched blood samples of known analyte concentrations. The accuracy and precision of the method were evaluated by analysis of a blood reference material (Seronorm™ trace elements whole blood L3). Quantitative results were obtained for the determination of P, S, Cl, K and Fe, and limits of detection for these elements were adequate, taking into account their typical concentrations in real blood samples. Determination of Na, Ca, Cu and Zn was hampered by the occurrence of high sample support (Na, Ca) and instrumental blanks (Cu, Zn). Therefore, the quantitative determination of these elements at the levels expected in blood samples was not feasible. The methodology developed was applied to the analysis of several blood samples and the results obtained were compared with those reported by standard techniques. Overall, the performance of the method developed is promising and it could be used to determine the aforementioned elements in blood samples in a simple, fast and economic way. Furthermore, its non-destructive nature enables further analyses by means of complementary techniques to be carried out.
Ferm, K; Björnerfeldt, S; Karlsson, A; Andersson, G; Nachreiner, R; Hedhammar, A
2009-04-01
To investigate prevalence of autoantibodies to thyroglobulin (TgAA) and/or elevated levels of thyroid stimulating hormone (TSH), indicating canine autoimmune lymphocytic thyroiditis (CLT) and/or hypothyroidism, in two high-risk dog breeds. A cohort study was conducted in two birth cohorts of giant schnauzer and hovawart dogs. The cohorts were three to four and six to seven years of age at the time of blood sampling and screening for TgAA and TSH levels. Blood sampling was accompanied by one initial and one follow-up questionnaire to the dog owners. A total number of 236 giant schnauzers and 95 hovawarts were included in the study. Seventeen (7.2 per cent) giant schnauzers and three (3.2 per cent) hovawarts had been diagnosed as hypothyroid at the time of sampling. Out of the remaining dogs, 22 giant schnauzers (10.0 per cent) and nine hovawarts (10.1 per cent) had elevated TgAA and/or TSH levels. Prevalence of elevated TgAA and TSH levels varied with age. The high prevalence of diagnostic characteristics indicating CLT/hypothyroidism in these two breeds suggests a strong genetic predisposition. It would be advisable to screen potential breeding stock for TSH and TgAA as a basis for genetic health programmes to reduce prevalence of CLT in these breeds.
The Pesticides and PCBs in Blood data set contains analytical results for measurements of up to 11 pesticides and up to 36 PCBs in 86 blood samples over 86 households. Each sample was collected as a venous sample from the primary respondent within each household. The samples co...
Bruggeman, Jason E; Route, William T; Redig, Patrick T; Key, Rebecca L
2018-04-10
Most studies examining bald eagle (Haliaeetus leucocephalus) exposure to lead (Pb) have focused on adults that ingested spent Pb ammunition during the fall hunting season, often at clinical or lethal levels. We sampled live bald eagle nestlings along waterbodies to quantify Pb concentrations in 3 national park units and 2 nearby study areas in the western Great Lakes region. We collected 367 bald eagle nestling feather samples over 8 years during spring 2006-2015 and 188 whole blood samples over 4 years during spring 2010-2015. We used Tobit regression models to quantify relationships between Pb concentrations in nestling feathers and blood using study area, year, and nestling attributes as covariates. Pb in nestling feather samples decreased from 2006 to 2015, but there was no trend for Pb in blood samples. Pb concentrations in nestling feather and blood samples were significantly higher in study areas located closer to and within urban areas. Pb in feather and blood samples from the same nestling was positively correlated. Pb in feathers increased with nestling age, but this relationship was not observed for blood. Our results reflect how Pb accumulates in tissues as nestlings grow, with Pb in feathers and blood indexing exposure during feather development and before sampling, respectively. Some nestlings had Pb concentrations in blood that suggested a greater risk to sublethal effects from Pb exposure. Our data provides baselines for Pb concentrations in feathers and blood of nestling bald eagles from a variety of waterbody types spanning remote, lightly populated, and human-dominated landscapes.
Biophysical isolation and identification of circulating tumor cells.
Che, James; Yu, Victor; Garon, Edward B; Goldman, Jonathan W; Di Carlo, Dino
2017-04-11
Isolation and enumeration of circulating tumor cells (CTCs) from blood is important for determining patient prognosis and monitoring treatment. Methods based on affinity to cell surface markers have been applied to both purify (via immunoseparation) and identify (via immunofluorescence) CTCs. However, variability of cell biomarker expression associated with tumor heterogeneity and evolution and cross-reactivity of antibody probes have long complicated CTC enrichment and immunostaining. Here, we report a truly label-free high-throughput microfluidic approach to isolate, enumerate, and characterize the biophysical properties of CTCs using an integrated microfluidic device. Vortex-mediated deformability cytometry (VDC) consists of an initial vortex region which enriches large CTCs, followed by release into a downstream hydrodynamic stretching region which deforms the cells. Visualization and quantification of cell deformation with a high-speed camera revealed populations of large (>15 μm diameter) and deformable (aspect ratio >1.2) CTCs from 16 stage IV lung cancer samples, that are clearly distinguished by increased deformability compared to contaminating blood cells and rare large cells isolated from healthy patients. The VDC technology demonstrated a comparable positive detection rate of putative CTCs above healthy baseline (93.8%) with respect to standard immunofluorescence (71.4%). Automation allows full enumeration of CTCs from a 10 mL vial of blood within <1 h after sample acquisition, compared with 4+ hours with standard approaches. Moreover, cells are released into any collection vessel for further downstream analysis. VDC shows potential for accurate CTC enumeration without labels and confirms the unique highly deformable biophysical properties of large CTCs circulating in blood.
Effects of fenoldopam on renal blood flow in hypertensive chronic kidney disease.
Rovella, Valentina; Ferrannini, Michele; Tesauro, Manfredi; Marrone, Giulia; Busca, Andrea; Sorge, Roberto; Manca di Villahermosa, Simone; Casasco, Maurizio; Di Daniele, Nicola; Noce, Annalisa
2018-05-15
The synthetic drug fenoldopam mesylate (FM) may have a renoprotective role, and a "renal dose" of 0.1 µg/kg/min intravenous (IV) infusion of FM has been reported as able to increase renal blood flow without affecting systemic blood pressure. But conclusive data are still lacking. We aimed to investigate by color-Doppler ultrasonography the effects of IV administration of FM at this dosage in hypertensive chronic kidney disease (CKD) patients, and verify whether it may induce any systemic hemodynamic alteration. In 60 hypertensive CKD patients, we measured by duplex Doppler ultrasonography, at baseline and during infusion of 0.1 µg/kg/min of FM, the systolic and diastolic flow velocity (sampled at the renal hilum, intermediate section and origin of both renal arteries) and the intra-parenchymal renal resistive index (RRI) sampled on interlobular arteries of both kidneys. Patients were divided into four subgroups (I-IV) according to classification of National Kidney Foundation Kidney Disease Outcomes Quality Initiative (NKF-DOQI). Infusion of 0.1 µg/kg/min FM significantly decreased the RRI (0.73 ± 0.05 vs. 0.65 ± 0.06; p < 0.0001) and increased the systolic and diastolic flow velocities in all renal artery tracts examined. No single episode of systemic hypotension was observed. Very low-dose FM may significantly increase renal blood flow and exert a renal protective effect in hypertensive CKD patients. Infusion of FM at such low dosage appears also to be quite safe, even in CKD and hypertensive patients.
Geissler, Raoul Georg; Kösters, Clemens; Franz, Dominik; Buddendick, Hubert; Borowski, Matthias; Juhra, Christian; Lange, Matthias; Bunzemeier, Holger; Roeder, Norbert; Sibrowski, Walter; Raschke, Michael J; Schlenke, Peter
2015-03-01
The aim of our single-centre retrospective study presented here is to further analyse the utilisation of allogeneic blood components within a 5-year observation period (2009-2013) in trauma surgery (15,457 patients) under the measures of an educational patient blood management (PBM) initiative. After the implementation of the PBM initiative in January 2012, the Institute of Transfusion Medicine und Transplantation Immunology educates surgeons and nurses at the Department of Trauma Surgery to avoid unnecessary blood transfusions. A standardised reporting system was used to document the utilisation of blood components carefully for the most frequent diagnoses and surgical interventions in trauma surgery. These measures served as basis for the implementation of an interdisciplinary systematic exchange of information to foster decision-making processes in favour of patient blood management. Since January 2012, the proportion of patients who received a transfusion as well as the number of transfused red blood cell (RBC) (7.3%/6.4%; p = 0.02), fresh frozen plasma (FFP) (1.7%/1.3%; p < 0.05) and platelet (PLT) (1.0%/0.5%; p < 0.001) units were reduced as a result of our PBM initiative. However, among the transfused patients, the number of administered RBC, FFP and PLT units did not decrease significantly. Overall, patients who did not receive transfusions were younger than transfused patients (p = 0.001). The subgroup with the highest probability of blood transfusion administered included patients with intensive care and long-term ventilation (before/after implementation of PBM: RBC 81.5%/75.9%; FFP 33.3%/20.4%; PLT 24.1%/13.0%). Only a total of 60 patients of 531 patients suffering multiple traumas were massively transfused (before/after implementation of PBM: RBC 55.6%/49.8%; FFP 28.4%/20.4%; PLT 17.6%/8.9%). According to our educational PBM initiative, at least the proportion of trauma patients who received allogeneic blood transfusions could be reduced significantly. However, in case of blood transfusions, the total consumption of RBC, FFP and PLT units remained stable in both time periods. This phenomenon might indicate that the actual need of blood transfusions rather depends on the severity of trauma-related blood loss, the coagulopathy rates or the complexity of the surgical intervention which mainly determines the intra-operative blood loss. Taken together, educational training sessions and systematic reporting systems are suitable measures to avoid unnecessary allogeneic blood transfusions and to continuously improve their restrictive application.
Haines, Douglas A; Saravanabhavan, Gurusankar; Werry, Kate; Khoury, Cheryl
2017-03-01
Human biomonitoring (HBM) is used to indicate and quantify exposure by measuring environmental chemicals, their metabolites or reaction products in biological specimens. The biomonitoring component of the Canadian Health Measures Survey (CHMS) is the most comprehensive initiative providing general population HBM data in Canada. The CHMS is an ongoing cross-sectional direct measures survey implemented in 2-year cycles. It provides nationally-representative data on health, nutritional status, environmental exposures, and related risks and protective characteristics. The survey follows a robust planning, design and sampling protocol as well as a comprehensive quality assurance and quality control regime implemented for all aspect of the survey to ensure the validity of the HBM results. HBM blood and urine data are available for CHMS cycles 1 (2007-2009), 2 (2009-2011) and 3 (2012-2013). Field collection has been completed for cycle 4 (2014-2015), with cycle 5 (2016-2017) in progress and cycle 6 planning (2018-2019) being finalized. Biomonitoring results for 279 chemicals are expected over the six cycles of the CHMS (220 in individual blood, urine or hair samples, and 59 in pooled serum samples). The chemicals include metals and trace elements, polychlorinated biphenyls (PCBs), organochlorines, flame retardants, perfluoroalkyl substances, volatile organic compounds (VOCs) and metabolites, environmental phenols, triclocarban, acrylamide, pesticides (e.g., triazines, carbamates, organophosphates, phenoxy, pyrethroids) and/or their metabolites, chlorophenols, polycyclic aromatic hydrocarbon (PAH) metabolites, phthalates and alternate plasticizer metabolites, and tobacco biomarkers. Approximately one half of the chemicals measured in individual blood and urine samples over the first three cycles were detected in more than 60% of samples. CHMS biomonitoring data have been used to establish baseline HBM concentrations in Canadians; inform public health, regulatory risk assessment and management decisions; and fulfil national and international reporting requirements. Concurrent efforts are underway in Canada to develop statistically- and risk-based concepts and tools to interpret biomonitoring data. Crown Copyright © 2016. Published by Elsevier GmbH. All rights reserved.
Device and method for automated separation of a sample of whole blood into aliquots
Burtis, Carl A.; Johnson, Wayne F.
1989-01-01
A device and a method for automated processing and separation of an unmeasured sample of whole blood into multiple aliquots of plasma. Capillaries are radially oriented on a rotor, with the rotor defining a sample chamber, transfer channels, overflow chamber, overflow channel, vent channel, cell chambers, and processing chambers. A sample of whole blood is placed in the sample chamber, and when the rotor is rotated, the blood moves outward through the transfer channels to the processing chambers where the blood is centrifugally separated into a solid cellular component and a liquid plasma component. When the rotor speed is decreased, the plasma component backfills the capillaries resulting in uniform aliquots of plasma which may be used for subsequent analytical procedures.
Wondafrash, Beyene; Hiko, Desta
2016-01-01
Infants and children living with HIV receive antiretroviral treatment often late, are exposed to opportunistic infection and quickly develop AIDS. Few hospitals are providing ART service after Dried Blood Spot (DBS)test.The objective of this study is to assess the status of infants and children linked to ART. Descriptive cross-sectional study was conducted in hospitals. Data of 138 infants and children exposed to HIV were collected from registration books and data bases from 2009 to 2011. Data were analyzed using SPSS version 16. Chi-squared test and p-value were computed. In-depth interviews were conducted with key informants. Ninety-eight (71%) infants and children exposed to HIV were diagnosed for HIV infection of which 68(69.4%) initiated ART. Twenty four (35.3%) initiated ART one month after HIV screening results. Thirty-three (50.0%) and 23(35.3%) infants and children dropped from and adhered to ART respectively. Eleven (16.2%) of them who initiated ART died within the study period. HIV infection status (p-value=0.003), dropping from ART (p-value=0.002) and death after ART initiation (p-value=0.010) showed significance with mothers' PMTCT service status. Seven in ten HIV-exposed infants and children were diagnosed with HIV, and almost all of them initiated ART. The overall turnaround time was 10 days. Based up on mothers' PMTCT service status, there was a significant difference among HIV-exposed infants and children in acquiring HIV infection from mothers during pregnancy (p-value=0.003) and dropping from ART (p-value=0.010). There were challenges in sample collection and transportation. Early HIV screening during pregnancy and PMTCT service should be strengthened.
Lamming, Christopher E.D.; Augustin, Lance; Blackstad, Mark; Lund, Troy C.; Hebbel, Robert P.; Verfaillie, Catherine M.
2003-01-01
The only curative therapy for sickle cell disease (SCD) is allogeneic hematopoietic stem cell (HSC) transplantation. Gene therapy approaches for autologous HSC transplantation are being developed. Although earlier engraftment is seen when cells from GCSF-mobilized blood are transplanted than when bone marrow is transplanted, administration of GCSF to patients with SCD can cause significant morbidity. We tested whether primitive hematopoietic progenitors are spontaneously mobilized in the blood of patients with SCD during acute crisis (AC-SCD patients). The frequency of myeloid-lymphoid–initiating cells (ML-ICs) and SCID-repopulating cells (SRCs) was significantly higher in blood from AC-SCD patients than in blood from patients with steady-state SCD or from normal donors. The presence of SRCs in peripheral blood was not associated with detection of long-term culture–initiating cells, consistent with the notion that SRCs are more primitive than long-term culture–initiating cells. As ML-ICs and SRCs were both detected in blood of AC-SCD patients only, these assays may both measure primitive progenitors. The frequency of ML-ICs also correlated with increases in stem cell factor, GCSF, and IL-8 levels in AC-SCD compared with steady-state SCD and normal-donor sera. Because significant numbers of ML-ICs and SRCs are mobilized in the blood without exogenous cytokine treatment during acute crisis of SCD, collection of peripheral blood progenitors during crisis may yield a source of autologous HSCs suitable for ex-vivo correction by gene therapy approaches and subsequent transplantation. PMID:12639987
[Blood sampling using "dried blood spot": a clinical biology revolution underway?].
Hirtz, Christophe; Lehmann, Sylvain
2015-01-01
Blood testing using the dried blood spot (DBS) is used since the 1960s in clinical analysis, mainly within the framework of the neonatal screening (Guthrie test). Since then numerous analytes such as nucleic acids, small molecules or lipids, were successfully measured on the DBS. While this pre-analytical method represents an interesting alternative to classic blood sampling, its use in routine is still limited. We review here the different clinical applications of the blood sampling on DBS and estimate its future place, supported by the new methods of analysis as the LC-MS mass spectrometry.
de Las Hazas, María Carmen López; Motilva, Maria José; Piñol, Carme; Macià, Alba
2016-10-01
In this study, a fast and simple blood sampling and sample pre-treatment method based on the use of the dried blood spot (DBS) cards and ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) for the quantification of olive oil phenolic metabolites in human blood was developed and validated. After validation, the method was applied to determine hydroxytyrosol metabolites in human blood samples after the acute intake of an olive oil phenolic extract. Using the FTA DMPK-A DBS card under optimum conditions, with 20µL as the blood solution volume, 100µL of methanol/Milli-Q water (50/50, v/v) as the extraction solvent and 7 disks punched out from the card, the main hydroxytyrosol metabolites (hydroxytyrosol-3-O-sulphate and hydroxytyrosol acetate sulphate) were identified and quantified. The developed methodology allowed detecting and quantifying the generated metabolites at low μM levels. The proposed method is a significant improvement over existing methods to determine phenolic metabolites circulating in blood and plasma samples, thus making blood sampling possible with the volunteer pricking their own finger, and the subsequent storage of the blood in the DBS cards prior to chromatographic analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Teranishi, Hideto; Ohzono, Nanae; Inamura, Norikazu; Kato, Atsushi; Wakabayashi, Tokio; Akaike, Hiroto; Terada, Kihei; Ouchi, Kazunobu
2015-03-01
Febrile neutropenia is the main treatment-related cause of mortality in cancer patients. During June 2012 to April 2014, 97 blood culture samples were collected from patients receiving chemotherapy for hematological malignancy and cancer with febrile neutropenia episodes (FNEs). The samples were examined for the presence of bacteria and fungi using real-time PCR amplification and sequencing of 16S and 18S rRNA genes. Bacteria were identified in 20 of 97 samples (20.6%) by the real-time PCR assay and in 10 of 97 (10.3%) samples by blood culture. In 6 blood culture-positive samples, the real-time PCR assay detected the same type of bacteria. No fungi were detected by the real-time PCR assay or blood culture. During antibiotic therapy, all samples were negative by blood culture, but the real-time PCR assay yielded a positive result in 2 cases of 2 (100%). The bacterial DNA copy number was not well correlated with the serum C-reactive protein titer of patients with FNEs. We conclude that a real-time PCR assay could provide better detection of causative microbes' in a shorter time, and with a smaller blood sample than blood culture. Using a real-time PCR assay in combination with blood culture could improve microbiological documentation of FNEs. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Kaewkong, Worasak; Intapan, Pewpan M; Sanpool, Oranuch; Janwan, Penchom; Thanchomnang, Tongjit; Kongklieng, Amornmas; Tantrawatpan, Chairat; Boonmars, Thidarut; Lulitanond, Viraphong; Taweethavonsawat, Piyanan; Chungpivat, Sudchit; Maleewong, Wanchai
2014-06-01
Canine babesiosis, hepatozoonosis, ehrlichiosis, and anaplasmosis are tick-borne diseases caused by different hemopathogens. These diseases are causes of morbidity and mortality in dogs. The classic method for parasite detection and differentiation is based on microscopic observation of blood smears. The limitations of the microscopic method are that its performance requires a specially qualified person with professional competence, and it is ineffective in differentiating closely related species. This study applied PCR amplification with high throughput pyrosequencing for molecular differential detection of the following 4 hemoparasites common to tropical areas in dog blood samples: Babesia vogeli, Hepatozoon canis, Ehrlichia canis, and Anaplasma platys. PCR was initially used to amplify specific target regions of the ribosomal RNA genes of each parasite using 2 primer pairs that included 18S rRNA for protozoa (B. vogeli and H. canis) and 16S rRNA for rickettsia (E. canis and A. platys). Babesia vogeli and H. canis were discriminated using 9 nucleotide positions out of 30 base pairs, whereas E. canis and A. platys were differentiated using 15 nucleotide positions out of 34 base pairs that were determined from regions adjacent to 3' ends of the sequencing primers. This method provides a challenging alternative for a rapid diagnosis and surveillance of these tick-borne diseases in canines. Copyright © 2014 Elsevier GmbH. All rights reserved.
Effects of an Elastic Hamstring Assistance Device During Downhill Running
Aldret, Randy L; Trahan, Brittany A; Davis, Greggory; Campbell, Brian; Bellar, David M
2017-01-01
Abstract The purpose of this study was to determine the appropriateness of using an elastic hamstring assistance device to reduce perceived levels of soreness, increase isometric strength, increase passive range of motion, and decrease biomarkers of muscle damage after eccentric exercise, specifically, downhill running This study was conducted in a university exercise physiology laboratory placing sixteen apparently healthy males (X = 21.6 ± 2.5 years) into two groups using a pre-test/post-test design. Pre-intervention measures taken included participants’ body height, body mass, body fat, capillary blood samples, VO2max, isometric hamstring strength at 45 and 90 degrees of flexion and passive hamstring range of motion. Post-intervention measures included blood biomarkers, passive range of motion, the perceived level of soreness and isometric strength. An analysis of normality of data was initially conducted followed by multivariate analysis of variance (MANOVA) of hamstring strength at 45 and 90 degrees of flexion, blood myoglobin and passive range of motion of the hamstrings. Statistically significant changes were noted in subject-perceived muscle soreness and isometric strength at 90 degrees at the 24-hour post-exercise trial measure between the two groups. Results would suggest the findings could be explained by the decrease in muscle soreness from utilizing the device during the exercise trial. Further research should be conducted to address sample size issues and to determine if the results are comparable on different surfaces. PMID:28713460
Quantitation of brinzolamide in dried blood spots by a novel LC-QTOF-MS/MS method.
Foivas, Anargyros; Malenović, Anđelija; Kostić, Nađa; Božić, Marija; Knežević, Miroslav; Loukas, Yannis L; Dotsikas, Yannis
2016-02-05
In the current study, a rapid and sensitive LC-QTOF-MS/MS method for the determination of brinzolamide in dried blood spots (DBS) was developed and validated. This novel sample collection, storage and transfer technique was suitable for analyzing a drug with high distribution into red blood cells and negligible plasma levels. The method included an isocratic mobile phase consisting of methanol and 10mM ammonium formate (90:10, v/v) and detection in positive electrospray mode (ESI+). The flow rate was adjusted to 0.350mL/min yielding retention times of 1.7min for both brinzolamide and internal standard (IS) rabeprazole on a Cyano analytical column, respectively. The validation of the proposed method over the concentration range 0.500-20.0μg/mL was performed in compliance with EMEA and FDA guidelines, assessing all major performance characteristics. Inter- and intra- assay precisions were less than 14%, while inter- and intra- assay accuracies varied from 92.2 to 111%. No matrix effect was observed and the mean brinzolamide extraction recovery was 93.5%. The method was successfully applied to real DBS samples from patients in steady state condition, receiving brinzolamide ophthalmic suspension 1% (w/v) for several months. Initial concentrations were corrected due to hematocrit effect, using image processing algorithm written in Matlab. Copyright © 2015 Elsevier B.V. All rights reserved.
Non-terminal blood sampling techniques in guinea pigs.
Birck, Malene M; Tveden-Nyborg, Pernille; Lindblad, Maiken M; Lykkesfeldt, Jens
2014-10-11
Guinea pigs possess several biological similarities to humans and are validated experimental animal models(1-3). However, the use of guinea pigs currently represents a relatively narrow area of research and descriptive data on specific methodology is correspondingly scarce. The anatomical features of guinea pigs are slightly different from other rodent models, hence modulation of sampling techniques to accommodate for species-specific differences, e.g., compared to mice and rats, are necessary to obtain sufficient and high quality samples. As both long and short term in vivo studies often require repeated blood sampling the choice of technique should be well considered in order to reduce stress and discomfort in the animals but also to ensure survival as well as compliance with requirements of sample size and accessibility. Venous blood samples can be obtained at a number of sites in guinea pigs e.g., the saphenous and jugular veins, each technique containing both advantages and disadvantages(4,5). Here, we present four different blood sampling techniques for either conscious or anaesthetized guinea pigs. The procedures are all non-terminal procedures provided that sample volumes and number of samples do not exceed guidelines for blood collection in laboratory animals(6). All the described methods have been thoroughly tested and applied for repeated in vivo blood sampling in studies within our research facility.
The counting of native blood cells by digital microscopy
NASA Astrophysics Data System (ADS)
Torbin, S. O.; Doubrovski, V. A.; Zabenkov, I. V.; Tsareva, O. E.
2017-03-01
An algorithm for photographic images processing of blood samples in its native state was developed to determine the concentration of erythrocytes, leukocytes and platelets without individual separate preparation of cells' samples. Special "photo templates" were suggested to use in order to identify red blood cells. The effect of "highlighting" of leukocytes, which was found by authors, was used to increase the accuracy of this type of cells counting. Finally to raise the resolution of platelets from leukocytes the areas of their photo images were used, but not their sizes. It is shown that the accuracy of cells counting for native blood samples may be comparable with the accuracy of similar studies for smears. At the same time the proposed native blood analysis simplifies greatly the procedure of sample preparation in comparison to smear, permits to move from the detection of blood cells ratio to the determination of their concentrations in the sample.
Jones, Trevor G.; Warber, Kimbrough D.; Roberts, Billy D.
2010-01-01
Background Hemoglobin A1c (HbA1c) has been endorsed as a tool for the diagnosis of diabetes. This test requires instrumentation that may not be available in underdeveloped areas. Dried blood spot (DBS) samples collected by finger stick procedures offer a mechanism to transport samples to laboratories that do measure HbA1c. Methods Whole blood (ethylenediaminetetraacetic acid) was applied to Ahlstrom 226 filter paper. These DBS samples were compared to whole blood samples using the Roche Tina-quant® II immunoturbidometric assay. Hemoglobin A1c stability on DBS was assessed at three temperatures—4, 25, and 40°C—for up to 9 days. A 44-day study was also done for DBS at 20–25°C. Results The Tina-quant® II DBS method showed excellent agreement with whole blood HbA1c results (r2 = 0.99) with a slight positive mean bias of 0.08 ± 0.04% HbA1c (95% confidence interval). The variation in HbA1c on DBS samples subjected to different temperatures and times did not exceed 5.6%. Conclusions Dried blood spot samples represent an alternative to whole blood for HbA1c by measurement when transporting whole blood is not feasible. PMID:20307383
Sewage sludge does not induce genotoxicity and carcinogenesis
Silva, Paula Regina Pereira; Barbisan, Luis Fernando; Dagli, Maria Lúcia Zaidan; Saldiva, Paulo Hilário Nascimento
2012-01-01
Through a series of experiments, the genotoxic/mutagenic and carcinogenic potential of sewage sludge was assessed. Male Wistar rats were randomly assigned to four groups: Group 1 - negative control; Group 2 - liver carcinogenesis initiated by diethylnitrosamine (DEN; 200 mg/kg i.p.); Group 3 and G4-liver carcinogenesis initiated by DEN and fed 10,000 ppm or 50,000 ppm of sewage sludge. The animals were submitted to a 70% partial hepatectomy at the 3rd week. Livers were processed for routine histological analysis and immunohistochemistry, in order to detect glutathione S-transferase positive altered hepatocyte foci (GST-P+ AHF). Peripheral blood samples for the comet assay were obtained from the periorbital plexus immediately prior to sacrificing. Polychromatic erythrocytes (PCEs) were analyzed in femoral bone-marrow smears, and the frequencies of those micronucleated (MNPCEs) registered. There was no sewage-sludge-induced increase in frequency of either DNA damage in peripheral blood leucocytes, or MNPCEs in the femoral bone marrow. Also, there was no increase in the levels of DNA damage, in the frequency of MNPCEs, and in the development of GST-P AHF when compared with the respective control group. PMID:23055806
Plasmodium ovale infection in Malaysia: first imported case
2010-01-01
Background Plasmodium ovale infection is rarely reported in Malaysia. This is the first imported case of P. ovale infection in Malaysia which was initially misdiagnosed as Plasmodium vivax. Methods Peripheral blood sample was first examined by Giemsa-stained microscopy examination and further confirmed using a patented in-house multiplex PCR followed by sequencing. Results and Discussion Initial results from peripheral blood smear examination diagnosed P. vivax infection. However further analysis using a patented in-house multiplex PCR followed by sequencing confirmed the presence of P. ovale. Given that Anopheles maculatus and Anopheles dirus, vectors of P. ovale are found in Malaysia, this finding has significant implication on Malaysia's public health sector. Conclusions The current finding should serve as an alert to epidemiologists, clinicians and laboratory technicians in the possibility of finding P. ovale in Malaysia. P. ovale should be considered in the differential diagnosis of imported malaria cases in Malaysia due to the exponential increase in the number of visitors from P. ovale endemic regions and the long latent period of P. ovale. It is also timely that conventional diagnosis of malaria via microscopy should be coupled with more advanced molecular tools for effective diagnosis. PMID:20929588
NASA Astrophysics Data System (ADS)
Muinul Islam, Muhammad; Tsujikawa, Tetsuya; Mori, Tetsuya; Kiyono, Yasushi; Okazawa, Hidehiko
2017-06-01
A noninvasive method to estimate input function directly from H2 15O brain PET data for measurement of cerebral blood flow (CBF) was proposed in this study. The image derived input function (IDIF) method extracted the time-activity curves (TAC) of the major cerebral arteries at the skull base from the dynamic PET data. The extracted primordial IDIF showed almost the same radioactivity as the arterial input function (AIF) from sampled blood at the plateau part in the later phase, but significantly lower radioactivity in the initial arterial phase compared with that of AIF-TAC. To correct the initial part of the IDIF, a dispersion function was applied and two constants for the correction were determined by fitting with the individual AIF in 15 patients with unilateral arterial stenoocclusive lesions. The area under the curves (AUC) from the two input functions showed good agreement with the mean AUCIDIF/AUCAIF ratio of 0.92 ± 0.09. The final products of CBF and arterial-to-capillary vascular volume (V 0) obtained from the IDIF and AIF showed no difference, and had with high correlation coefficients.
High Blood Caffeine Levels in MCI Linked to Lack of Progression to Dementia
Cao, Chuanhai; Loewenstein, David A.; Lin, Xiaoyang; Zhang, Chi; Wang, Li; Duara, Ranjan; Wu, Yougui; Giannini, Alessandra; Bai, Ge; Cai, Jianfeng; Greig, Maria; Schofield, Elizabeth; Ashok, Raj; Small, Brent; Potter, Huntington; Arendash, Gary W.
2017-01-01
Although both human epidemiologic and animal model studies have suggested that caffeine/coffee protects against Alzheimer’s disease, direct human evidence for this premise has been lacking. In the present case-control study, two separate cohorts consisting of 124 total individuals (65–88 years old) were cognitively assessed and a blood sample taken for caffeine/biomarker analysis. Subjects were then monitored for cognitive status over the ensuing 2–4 year period to determine the extent to which initial plasma caffeine/biomarkers levels would be predictive of changes in cognitive status. Plasma caffeine levels at study onset were substantially lower (−51%) in mild cognitive impairment (MCI) subjects who later progressed to dementia (MCI→DEM) compared to levels in stable MCI subjects (MCI→MCI). Moreover, none of the MCI→DEM subjects had initial blood caffeine levels that were above a critical level of 1200 ng/ml, while half of stable MCI→MCI subjects had blood caffeine levels higher than that critical level. Thus, plasma caffeine levels greater than 1200 ng/ml (≈6 µM) in MCI subjects were associated with no conversion to dementia during the ensuing 2–4 year follow-up period. Among the 11 cytokines measured in plasma, three of them (GCSF, IL-10, and IL-6) were decreased in MCI→DEM subjects, but not in stable MCI→MCI subjects with high plasma caffeine levels. Coffee would appear to be the major or perhaps only source of caffeine for such stable MCI patients. This case-control study provides the first direct evidence that caffeine/coffee intake is associated with a reduced risk of dementia or delayed onset, particularly for those who already have MCI. PMID:22430531
Allardet-Servent, Jérôme; Lebsir, Melissa; Dubroca, Christian; Fabrigoule, Martine; Jordana, Sylvie; Signouret, Thomas; Castanier, Matthias; Thomas, Guillemette; Soundaravelou, Rettinavelou; Lepidi, Anne; Delapierre, Laurence; Penaranda, Guillaume; Halfon, Philippe; Seghboyan, Jean-Marie
2017-01-01
Rapid detection of abnormal biological values using point-of-care (POC) testing allows clinicians to promptly initiate therapy; however, there are concerns regarding the reliability of POC measurements. We investigated the agreement between the latest generation blood gas analyzer and central laboratory measurements of electrolytes, bicarbonate, hemoglobin, hematocrit, and glucose. 314 paired samples were collected prospectively from 51 critically ill patients. All samples were drawn simultaneously in the morning from an arterial line. BD Vacutainer tubes were analyzed in the central laboratory using Beckman Coulter analyzers (AU 5800 and DxH 800). BD Preset 3 ml heparinized-syringes were analyzed immediately in the ICU using the POC Siemens RAPIDPoint 500 blood gas system. We used CLIA proficiency testing criteria to define acceptable analytical performance and interchangeability. Biases, limits of agreement (±1.96 SD) and coefficients of correlation were respectively: 1.3 (-2.2 to 4.8 mmol/L, r = 0.936) for sodium; 0.2 (-0.2 to 0.6 mmol/L, r = 0.944) for potassium; -0.9 (-3.7 to 2 mmol/L, r = 0.967) for chloride; 0.8 (-1.9 to 3.4 mmol/L, r = 0.968) for bicarbonate; -11 (-30 to 9 mg/dL, r = 0.972) for glucose; -0.8 (-1.4 to -0.2 g/dL, r = 0.985) for hemoglobin; and -1.1 (-2.9 to 0.7%, r = 0.981) for hematocrit. All differences were below CLIA cut-off values, except for hemoglobin. Compared to central Laboratory analyzers, the POC Siemens RAPIDPoint 500 blood gas system satisfied the CLIA criteria of interchangeability for all tested parameters, except for hemoglobin. These results are warranted for our own procedures and devices. Bearing these restrictions, we recommend clinicians to initiate an appropriate therapy based on POC testing without awaiting a control measurement.
Lebsir, Melissa; Dubroca, Christian; Fabrigoule, Martine; Jordana, Sylvie; Signouret, Thomas; Castanier, Matthias; Thomas, Guillemette; Soundaravelou, Rettinavelou; Lepidi, Anne; Delapierre, Laurence; Penaranda, Guillaume; Halfon, Philippe; Seghboyan, Jean-Marie
2017-01-01
Introduction Rapid detection of abnormal biological values using point-of-care (POC) testing allows clinicians to promptly initiate therapy; however, there are concerns regarding the reliability of POC measurements. We investigated the agreement between the latest generation blood gas analyzer and central laboratory measurements of electrolytes, bicarbonate, hemoglobin, hematocrit, and glucose. Methods 314 paired samples were collected prospectively from 51 critically ill patients. All samples were drawn simultaneously in the morning from an arterial line. BD Vacutainer tubes were analyzed in the central laboratory using Beckman Coulter analyzers (AU 5800 and DxH 800). BD Preset 3 ml heparinized-syringes were analyzed immediately in the ICU using the POC Siemens RAPIDPoint 500 blood gas system. We used CLIA proficiency testing criteria to define acceptable analytical performance and interchangeability. Results Biases, limits of agreement (±1.96 SD) and coefficients of correlation were respectively: 1.3 (-2.2 to 4.8 mmol/L, r = 0.936) for sodium; 0.2 (-0.2 to 0.6 mmol/L, r = 0.944) for potassium; -0.9 (-3.7 to 2 mmol/L, r = 0.967) for chloride; 0.8 (-1.9 to 3.4 mmol/L, r = 0.968) for bicarbonate; -11 (-30 to 9 mg/dL, r = 0.972) for glucose; -0.8 (-1.4 to -0.2 g/dL, r = 0.985) for hemoglobin; and -1.1 (-2.9 to 0.7%, r = 0.981) for hematocrit. All differences were below CLIA cut-off values, except for hemoglobin. Conclusions Compared to central Laboratory analyzers, the POC Siemens RAPIDPoint 500 blood gas system satisfied the CLIA criteria of interchangeability for all tested parameters, except for hemoglobin. These results are warranted for our own procedures and devices. Bearing these restrictions, we recommend clinicians to initiate an appropriate therapy based on POC testing without awaiting a control measurement. PMID:28072822
van Ginkel, Joost H; van den Broek, Daan A; van Kuik, Joyce; Linders, Dorothé; de Weger, Roel; Willems, Stefan M; Huibers, Manon M H
2017-10-01
In current molecular cancer diagnostics, using blood samples of cancer patients for the detection of genetic alterations in plasma (cell-free) circulating tumor DNA (ctDNA) is an emerging practice. Since ctDNA levels in blood are low, highly sensitive Droplet Digital PCR (ddPCR) can be used for detecting rare mutational targets. In order to perform ddPCR on blood samples, a standardized procedure for processing and analyzing blood samples is necessary to facilitate implementation into clinical practice. Therefore, we assessed the technical sample workup procedure for ddPCR on blood plasma samples. Blood samples from healthy individuals, as well as lung cancer patients were analyzed. We compared different methods and protocols for sample collection, storage, centrifugation, isolation, and quantification. Cell-free DNA (cfDNA) concentrations of several wild-type targets and BRAF and EGFR-mutant ctDNA concentrations quantified by ddPCR were primary outcome measurements. Highest cfDNA concentrations were measured in blood collected in serum tubes. No significant differences in cfDNA concentrations were detected between various time points of up to 24 h until centrifugation. Highest cfDNA concentrations were detected after DNA isolation with the Quick cfDNA Serum & Plasma Kit, while plasma isolation using the QIAamp Circulating Nucleic Acid Kit yielded the most consistent results. DdPCR results on cfDNA are highly dependent on multiple factors during preanalytical sample workup, which need to be addressed during the development of this diagnostic tool for cancer diagnostics in the future. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
Quasi-static acoustic tweezing thromboelastometry.
Holt, R G; Luo, D; Gruver, N; Khismatullin, D B
2017-07-01
Essentials Blood coagulation measurement during contact with an artificial surface leads to unreliable data. Acoustic tweezing thromboelastometry is a novel non-contact method for coagulation monitoring. This method detects differences in the blood coagulation state within 10 min. Coagulation data were obtained using a much smaller sample volume (4 μL) than currently used. Background Thromboelastography is widely used as a tool to assess the coagulation status of critical care patients. It allows observation of changes in material properties of whole blood, beginning with early stages of clot formation and ending with clot lysis. However, the contact activation of the coagulation cascade at surfaces of thromboelastographic systems leads to inherent variability and unreliability in predicting bleeding or thrombosis risks. Objectives To develop acoustic tweezing thromboelastometry as a non-contact method for perioperative assessment of blood coagulation. Methods Acoustic tweezing is used to levitate microliter drops of biopolymer and human blood samples. By quasi-statically changing the acoustic pressure we control the sample drop location and deformation. Sample size, deformation and location are determined by digital imaging at each pressure. Results Simple Newtonian liquid solutions maintain a constant, reversible location vs. deformation curve. In contrast, the location/deformation curves for gelatin, alginate, whole blood and blood plasma uniquely change as the samples solidify. Increasing elasticity causes the sample to deform less, leading to steeper stress/strain curves. By extracting a linear regime slope, we show that whole blood or blood plasma exhibits a unique slope profile as it begins to clot. By exposing blood samples to pro- or antithrombotic agents, the slope profile changes, allowing detection of hyper- or hypocoagulable states. Conclusions We demonstrate that quasi-static acoustic tweezing can yield information about clotting onset, maturation and strength. The advantages of small sample size, non-contact and rapid measurement make this technique desirable for real-time monitoring of blood coagulation. © 2017 International Society on Thrombosis and Haemostasis.
Malsby, Robert F; Quesada, Jose; Powell-Dunford, Nicole; Kinoshita, Ren; Kurtz, John; Gehlen, William; Adams, Colleen; Martin, Dustin; Shackelford, Stacy
2013-07-01
U.S. Army flight medics performed a process improvement initiative of 15 blood product transfusions on select Category A (Urgent) helicopter evacuation casualties meeting approved clinical indications for transfusion. These transfusions were initiated from point of injury locations aboard MEDEVAC aircraft originating from one of two locations in southern Afghanistan. All flight medics executing the transfusions were qualified through a standardized and approved program of instruction, which included day and night skills validation, and a 90% or higher written examination score. There was no adverse reaction or out-of-standard blood product temperature despite hazardous conditions and elevated cabin temperatures. All casualties within a 10-minute flight time who met clinical indications were transfused. Utilization of a standard operating procedure with strict handling and administration parameters, a rigorous training and qualification program, an elaborate cold chain system, and redundant documentation of blood product units ensured that flight medic initiated transfusions were safe and effective. Research study is needed to refine the indications for prehospital blood transfusion and to determine the effect on outcomes in severely injured trauma patients. Reprint & Copyright © 2013 Association of Military Surgeons of the U.S.
Elbashir, Ahmed B; Abdelbagi, Azhari O; Hammad, Ahmed M A; Elzorgani, Gafar A; Laing, Mark D
2015-03-01
Ninety-six human blood samples were collected from six locations that represent areas of intensive pesticide use in Sudan, which included irrigated cotton schemes (Wad Medani, Hasaheesa, Elmanagil, and Elfaw) and sugarcane schemes (Kenana and Gunaid). Blood samples were analyzed for organochlorine pesticide residues by gas liquid chromatography (GLC) equipped with an electron capture detector (ECD). Residues of p,p'-dichlorodiphenyldichloroethylene (DDE), heptachlor epoxide, γ-HCH, and dieldrin were detected in blood from all locations surveyed. Aldrin was not detected in any of the samples analyzed, probably due to its conversion to dieldrin. The levels of total organochlorine burden detected were higher in the blood from people in the irrigated cotton schemes (mean 261 ng ml(-1), range 38-641 ng ml(-1)) than in the blood of people from the irrigated sugarcane schemes (mean 204 ng ml(-1), range 59-365 ng ml(-1)). The highest levels of heptachlor epoxide (170 ng ml(-1)) and γ-HCH (92 ng ml(-1)) were observed in blood samples from Hasaheesa, while the highest levels of DDE (618 ng ml(-1)) and dieldrin (82 ng ml(-1)) were observed in blood samples from Wad Medani and Kenana, respectively. The organochlorine levels in blood samples seemed to decrease with increasing distance from the old irrigated cotton schemes (Wad Medani, Hasaheesa, and Elmanagil) where the heavy application of these pesticides took place historically.
Añez, Germán; Heisey, Daniel A. R.; Chancey, Caren; Fares, Rafaelle C. G.; Espina, Luz M.; Souza, Kátia P. R.; Teixeira-Carvalho, Andréa; Krysztof, David E.; Foster, Gregory A.; Stramer, Susan L.; Rios, Maria
2016-01-01
Background Dengue is a mosquito-borne viral disease caused by the four dengue viruses (DENV-1 to 4) that can also be transmitted by blood transfusion and organ transplantation. The distribution of DENV in the components of blood from infected donors is poorly understood. Methods We used an in-house TaqMan qRT-PCR assay to test residual samples of plasma, cellular components of whole blood (CCWB), serum and clot specimens from the same collection from blood donors who were DENV-RNA-reactive in a parallel blood safety study. To assess whether DENV RNA detected by TaqMan was associated with infectious virus, DENV infectivity in available samples was determined by culture in mosquito cells. Results DENV RNA was detected by TaqMan in all tested blood components, albeit more consistently in the cellular components; 78.8% of CCWB, 73.3% of clots, 86.7% of sera and 41.8% of plasma samples. DENV-1 was detected in 48 plasma and 97 CCWB samples while DENV-4 was detected in 21 plasma and 31 CCWB samples. In mosquito cell cultures, 29/111 (26.1%) plasma and 32/97 (32.7%) CCWB samples were infectious. A subset of samples from 29 donors was separately analyzed to compare DENV viral loads in the available blood components. DENV viral loads did not differ significantly between components and ranged from 3–8 log10 PCR-detectable units/ml. Conclusions DENV was present in all tested components from most donors, and viral RNA was not preferentially distributed in any of the tested components. Infectious DENV was also present in similar proportions in cultured plasma, clot and CCWB samples, indicating that these components may serve as a resource when sample sizes are limited. However, these results suggest that the sensitivity of the nucleic acid tests (NAT) for these viruses would not be improved by testing whole blood or components other than plasma. PMID:26871560
Anez, German; Heisey, Daniel A. R.; Chancey, Caren; ...
2016-02-12
Dengue is a mosquito-borne viral disease caused by the four dengue viruses (DENV-1 to 4) that can also be transmitted by blood transfusion and organ transplantation. The distribution of DENV in the components of blood from infected donors is poorly understood. Here, we used an in-house TaqMan qRT-PCR assay to test residual samples of plasma, cellular components of whole blood (CCWB), serum and clot specimens from the same collection from blood donors who were DENV-RNA-reactive in a parallel blood safety study. To assess whether DENV RNA detected by TaqMan was associated with infectious virus, DENV infectivity in available samples wasmore » determined by culture in mosquito cells. As a result, DENV RNA was detected by TaqMan in all tested blood components, albeit more consistently in the cellular components; 78.8% of CCWB, 73.3% of clots, 86.7% of sera and 41.8% of plasma samples. DENV-1 was detected in 48 plasma and 97 CCWB samples while DENV-4 was detected in 21 plasma and 31 CCWB samples. In mosquito cell cultures, 29/111 (26.1%) plasma and 32/97 (32.7%) CCWB samples were infectious. A subset of samples from 29 donors was separately analyzed to compare DENV viral loads in the available blood components. DENV viral loads did not differ significantly between components and ranged from 3–8 log 10 PCR-detectable units/ml. In conclusion, DENV was present in all tested components from most donors, and viral RNA was not preferentially distributed in any of the tested components. Infectious DENV was also present in similar proportions in cultured plasma, clot and CCWB samples, indicating that these components may serve as a resource when sample sizes are limited. However, these results suggest that the sensitivity of the nucleic acid tests (NAT) for these viruses would not be improved by testing whole blood or components other than plasma.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anez, German; Heisey, Daniel A. R.; Chancey, Caren
Dengue is a mosquito-borne viral disease caused by the four dengue viruses (DENV-1 to 4) that can also be transmitted by blood transfusion and organ transplantation. The distribution of DENV in the components of blood from infected donors is poorly understood. Here, we used an in-house TaqMan qRT-PCR assay to test residual samples of plasma, cellular components of whole blood (CCWB), serum and clot specimens from the same collection from blood donors who were DENV-RNA-reactive in a parallel blood safety study. To assess whether DENV RNA detected by TaqMan was associated with infectious virus, DENV infectivity in available samples wasmore » determined by culture in mosquito cells. As a result, DENV RNA was detected by TaqMan in all tested blood components, albeit more consistently in the cellular components; 78.8% of CCWB, 73.3% of clots, 86.7% of sera and 41.8% of plasma samples. DENV-1 was detected in 48 plasma and 97 CCWB samples while DENV-4 was detected in 21 plasma and 31 CCWB samples. In mosquito cell cultures, 29/111 (26.1%) plasma and 32/97 (32.7%) CCWB samples were infectious. A subset of samples from 29 donors was separately analyzed to compare DENV viral loads in the available blood components. DENV viral loads did not differ significantly between components and ranged from 3–8 log 10 PCR-detectable units/ml. In conclusion, DENV was present in all tested components from most donors, and viral RNA was not preferentially distributed in any of the tested components. Infectious DENV was also present in similar proportions in cultured plasma, clot and CCWB samples, indicating that these components may serve as a resource when sample sizes are limited. However, these results suggest that the sensitivity of the nucleic acid tests (NAT) for these viruses would not be improved by testing whole blood or components other than plasma.« less
Liu, Y; Rafkin, L E; Matheson, D; Henderson, C; Boulware, D; Besser, R E J; Ferrara, C; Yu, L; Steck, A K; Bingley, P J
2017-07-01
To evaluate the feasibility of using self-collected capillary blood samples for islet autoantibody testing to identify risk in relatives of people with Type 1 diabetes. Participants were recruited via the observational TrialNet Pathway to Prevention study, which screens and monitors relatives of people with Type 1 diabetes for islet autoantibodies. Relatives were sent kits for capillary blood collection, with written instructions, an online instructional video link and a questionnaire. Sera from capillary blood samples were tested for autoantibodies to glutamic acid decarboxylase, islet antigen-2, insulin and zinc transporter 8. 'Successful' sample collection was defined as obtaining sufficient volume and quality to provide definitive autoantibody results, including confirmation of positive results by repeat assay. In 240 relatives who returned samples, the median (range) age was 15.5 (1-49) years and 51% were male. Of these samples, 98% were sufficient for glutamic acid decarboxylase, islet antigen-2 and zinc transporter 8 autoantibody testing and 84% for insulin autoantibody testing and complete autoantibody screen. The upper 90% confidence bound for unsuccessful collection was 4.4% for glutamic acid decarboxylase, islet antigen-2 and/or zinc transporter 8 autoantibody assays, and 19.3% for insulin autoantibodies. Despite 43% of 220 questionnaire respondents finding capillary blood collection uncomfortable or painful, 82% preferred home self-collection of capillary blood samples compared with outpatient venepuncture (90% of those aged <8 years, 83% of those aged 9-18 years and 73% of those aged >18 years). The perceived difficulty of collecting capillary blood samples did not affect success rate. Self-collected capillary blood sampling offers a feasible alternative to venous sampling, with the potential to facilitate autoantibody screening for Type 1 diabetes risk. © 2017 Diabetes UK.
Seibel, J; Bodié, K; Weber, S; Bury, D; Kron, M; Blaich, G
2010-10-01
The investigation of clinical pathology parameters (haematology, clinical chemistry and coagulation) is an important part of the preclinical evaluation of drug safety. However, the blood sampling method employed should avoid or minimize stress and injury in laboratory animals. In the present study, we compared the clinical pathology results from blood samples collected terminally from the vena cava (VC) immediately before necropsy with samples taken from the sublingual vein (VS) also prior to necropsy in order to determine whether the sampling method has an influence on clinical pathology parameters. Forty-six 12-week-old male Sprague-Dawley rats were assigned to two groups (VC or VS; n = 23 each). All rats were anaesthetized with isoflurane prior to sampling. In the VC group, blood was withdrawn from the inferior VC. For VS sampling, the tongue was gently pulled out and the VS was punctured. The haematology, coagulation and clinical chemistry parameters were compared. Equivalence was established for 13 parameters, such as mean corpuscular volume, white blood cells and calcium. No equivalence was found for the remaining 26 parameters, although they were considered to be similar when compared with the historical data and normal ranges. The most conspicuous finding was that activated prothrombin time was 30.3% less in blood taken from the VC (16.6 ± 0.89 s) than that in the VS samples (23.8 ± 1.58 s). Summing up, blood sampling from the inferior VC prior to necropsy appears to be a suitable and reliable method for terminal blood sampling that reduces stress and injury to laboratory rats in preclinical drug safety studies.
George, Elizabeth; Lai, Mei I; Teh, Lai Kuan; Ramasamy, Rajesh; Goh, Ern Huei; Asokan, Kamalan; Tan, J A M A; Vasudevan, Maithili; Low, Sharon
2011-12-01
Detection and quantification of Hb subtypes of human blood is integral to presumptive identification of thalassaemias. It has been used in neonatal screening of thalassaemia and Hb variants. The use of discarded red blood cells following processing of the cord blood for stem cells provides readily available diagnostic material for thalassaemia screening. In this study, we determined the range of Hb subtypes in 195 consecutive cord blood samples collected for cord blood banking. The 'cord blood samples' analysed were those of the remaining red blood cells after the cord blood was processed for stem cell storage. Quantification of Hb subtypes by high performance liquid chromatography (HPLC) was done on BioRad Variant II Hb testing system. Only 73 (36.5%) of the samples could be analyzed neat without dilution. With a 1:300 dilution with wash solution the acceptable area as recommended by the manufacturer for reading of a C-gram within the 1 to 3 million ranges were achieved in all. Eighteen (9%) 12 showed classical Hb Barts (y4) prerun peaks were confirmed by Sebia Hydrasys automated Hb gel electrophoresis and quantified by Sebia Capillarys 2 capillary electrophoresis. Only 1 (0.5%) was presumptively identified with HbH disease. Due to the limited number of samples no beta-thalassaemia major, Hb E beta-thalassaemia and Hb Barts hydrops fetalis were found. The HPLC assay was possible at a cost US$ 5 per sample and a turnover time of 10 samples per hour without technical difficulties. This study reports an effective and valuable protocol for thalassaemia screening in red blood cells which would otherwise be discarded during cord blood processing. Cord blood with severe and intermediate forms of thalassaemia can be preselected and not stored.
Louis, Elan D.; Jiang, Wendy; Gerbin, Marina; Viner, Amanda S.; Factor-Litvak, Pam; Zheng, Wei
2012-01-01
Essential tremor (ET) is a widespread late-life neurological disease. Genetic and environmental factors are likely to play important etiological roles. Harmane (1-methyl-9H-pyrido[3,4-b]indole) is a potent tremor-producing neurotoxin. Previously, elevated blood harmane concentrations were demonstrated in ET cases compared to controls, but these observations were all been cross-sectional, assessing each subject at only one time point. Thus, no one has ever repeat-assayed blood harmane in the same subjects twice. Whether the observed case-control difference persists at a second time point, years later, is unknown. The current goal was to re-assess a sample of our ET cases and controls to determine whether blood harmane concentration remained elevated in ET at a second time point. Blood harmane concentrations were quantified by a well-established high performance liquid chromatography method in 63 ET cases and 70 controls. A mean of approximately 6 years elapsed between the initial and this subsequent blood harmane determination. The mean log blood harmane concentration was significantly higher in cases than controls (0.30 ± 0.61 g−10/ml vs. 0.08 ± 0.55 g−10/ml), and the median value in cases was double that of controls: 0.22 g−10/ml vs. 0.11 g−10/ml. The log blood harmane concentration was highest in cases with a family history of ET. Blood harmane concentration was elevated in ET cases compared to controls when re-assessed at a second time point several years later, indicating what seems to be a stable association between this environmental toxin and ET. PMID:22757671
Louis, Elan D; Jiang, Wendy; Gerbin, Marina; Viner, Amanda S; Factor-Litvak, Pam; Zheng, Wei
2012-01-01
Essential tremor (ET) is a widespread late-life neurological disease. Genetic and environmental factors are likely to play important etiological roles. Harmane (1-methyl-9H-pyrido[3,4-b]indole) is a potent tremor-producing neurotoxin. Previously, elevated blood harmane concentrations were demonstrated in ET cases compared to controls, but these observations have all been cross-sectional, assessing each subject at only one time point. Thus, no one has ever repeat-assayed blood harmane in the same subjects twice. Whether the observed case-control difference persists at a second time point, years later, is unknown. The current goal was to reassess a sample of our ET cases and controls to determine whether blood harmane concentration remained elevated in ET at a second time point. Blood harmane concentrations were quantified by a well-established high-performance liquid chromatography method in 63 ET cases and 70 controls. A mean of approximately 6 yr elapsed between the initial and this subsequent blood harmane determination. The mean log blood harmane concentration was significantly higher in cases than controls (0.30 ± 0.61 g(-10)/ml versus 0.08 ± 0.55 g(-10)/ml), and the median value in cases was double that of controls: 0.22 g(-10)/ml versus 0.11 g(-10)/ml. The log blood harmane concentration was highest in cases with a family history of ET. Blood harmane concentration was elevated in ET cases compared to controls when reassessed at a second time point several years later, indicating what seems to be a stable association between this environmental toxin and ET.
A method for estimating radioactive cesium concentrations in cattle blood using urine samples.
Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji
2017-12-01
In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.
de Miguel, Dunia; Burgaleta, Carmen; Reyes, Eduardo; Pascual, Teresa
2003-07-01
We evaluated a new portable monitor (AvoSure PT PRO, Menarini Diagnostics, Firenze, Italy) developed to test the prothrombin time in capillary blood and plasma by comparing it with the standard laboratory determination. We studied 62 patients receiving acenocoumarol therapy. The international normalized ratio (INR) in capillary blood was analyzed by 2 methods: AvoSure PT PRO and Thrombotrack Nycomed Analyzer (Axis-Shield, Dundee, Scotland). Parallel studies were performed in plasma samples by a reference method using the Behring Coagulation Timer (Behring Diagnostics, Marburg, Germany). Plasma samples also were tested with the AvoSure PT PRO. Correlation was good for INR values for capillary blood and plasma samples by AvoSure PT PRO and our reference method (R2 = 0.8596) and for capillary blood samples tested by the AvoSure PT PRO and Thrombotrack Nycomed Analyzer (R2 = 0.8875). The correlation for INR in capillary blood and plasma samples by AvoSure PT PRO was 0.6939 (P < .0004). Capillary blood determinations are rapid and effective for monitoring oral anticoagulation therapy and have a high correlation to plasma determinations. AvoSure PT PRO is accurate for controlling INR in plasma and capillary blood samples, may be used in outpatient clinics, and has advantages over previous portable monitors.
78 FR 30319 - National Heart, Lung, and Blood Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-22
...: Heart, Lung, and Blood Initial Review Group; Heart, Lung, and Blood Program Project Review Committee... Blood Institute; Notice of Closed Meetings Pursuant to section 10(d) of the Federal Advisory Committee... clearly unwarranted invasion of personal privacy. Name of Committee: National Heart, Lung, and Blood...
Buckley, Beth; Nugent, Nicole; Sledjeski, Eve; Raimonde, A Jay; Spoonster, Eileen; Bogart, Laura M; Delahanty, Douglas L
2004-08-01
The present study examined the relationship between heart rate (HR) and blood pressure (BP) levels assessed at multiple time points posttrauma and subsequent acute posttraumatic stress disorder (PTSD) symptoms present at a 1-month follow-up. HR and BP levels were measured in 65 motor vehicle accident (MVA) survivors during Emergency Medical Service transport, upon admission to the trauma unit, for the first 20 min postadmission and on the day of discharge. Hierarchical linear modeling analyses revealed no significant relationships between cardiovascular levels and acute PTSD symptoms. Given the small sample size, these results should be interpreted with caution. However, the present results question the use of initial cardiovascular levels as predictors of subsequent acute PTSD in seriously injured MVA victims.
Sroka-Oleksiak, Agnieszka; Ufir, Krzysztof; Salamon, Dominika; Bulanda, Malgorzata; Gosiewski, Tomasz
Lyme disease, caused by Borrelia burgdorferi, is a multisystem disease that often makes difficulties to recognize caused by their genetic heterogenity. Currently, the gold standard for the detection of Lyme disease (LD) is serologic diagnostics based mainly on tests: ELISA and Western blot (WB). These methods, however, are subject to consider- able defect, especially in the initial phase of infection due to the occurrence of so-called serological window period and low specificity. For this reason, they might be replaced by molecular methods, for example polymerase chain reaction (PCR), which should be more sensitivity and specificity. In the present study we attempt to optimize the PCR reaction conditions and enhance existing test sensitivity by applying the equivalent of real time PCR - nested PCR for detection B. burgdorferi DNA in the patient's blood. The study involved 94 blood samples of patients with suspected LD. From each sample, 1.5 ml of blood was used for the isolation of bacterial DNA and PCR real time am- plification and its equivalent, in nested version. The remaining part earmarked for serologi- cal testing. Optimization of the reaction conditions made experimentally, using gradient of the temperature and gradient of the magnesium ions concentration for reaction real time in nested-PCR and PCR version. The results show that the nested-PCR real time, has a much higher sensitivity 45 (47.8%) of positive results for the detection of B. burgdorferi compared to the single- variety, without a preceding pre-amplification 2 (2.1%). Serological methods allowed the detection of infection in 41 (43.6%) samples. These results support of the nested PCR method as a better molecular tool for the detection of B. burgdorferi infection than classical PCR real time reaction. The nested-PCR real time method may be considered as a complement to ELISA and WB mainly in the early stages of infection, when in the blood circulating B. burgdorferi cells. By contrast, the results of serological and molecular tests should always be carried out tak- ing into account the patient's clinical status.
NASA Astrophysics Data System (ADS)
Manicke, Nicholas Edward; Abu-Rabie, Paul; Spooner, Neil; Ouyang, Zheng; Cooks, R. Graham
2011-09-01
A method is presented for the direct quantitative analysis of therapeutic drugs from dried blood spot samples by mass spectrometry. The method, paper spray mass spectrometry, generates gas phase ions directly from the blood card paper used to store dried blood samples without the need for complex sample preparation and separation; the entire time for preparation and analysis of blood samples is around 30 s. Limits of detection were investigated for a chemically diverse set of some 15 therapeutic drugs; hydrophobic and weakly basic drugs, such as sunitinib, citalopram, and verapamil, were found to be routinely detectable at approximately 1 ng/mL. Samples were prepared by addition of the drug to whole blood. Drug concentrations were measured quantitatively over several orders of magnitude, with accuracies within 10% of the expected value and relative standard deviation (RSD) of around 10% by prespotting an internal standard solution onto the paper prior to application of the blood sample. We have demonstrated that paper spray mass spectrometry can be used to quantitatively measure drug concentrations over the entire therapeutic range for a wide variety of drugs. The high quality analytical data obtained indicate that the technique may be a viable option for therapeutic drug monitoring.
Diagnostic Applications and Methods to Isolate Circulating Tumor Cells (CTCs) from Blood
NASA Astrophysics Data System (ADS)
Tang, Cha-Mei
2013-03-01
Each year a million new cancer cases are diagnosed in the United States. Ninety percent of the deaths will be the result of metastasis, not from the primary tumor. Tissue biopsy is a universally accepted tool for cancer diagnosis and determination of treatment. The procedure varies, but is invasive, costly, and can be fatal, and for these reasons is seldom repeated after initial diagnosis. Monitoring of treatment response and for possible relapse is usually done by CT or MRI scan, both of which are expensive and require the tumor to change size perceptibly. Further, cancer can mutate or develop resistance to therapeutics and require modification of the treatment regimen. The initial tissue biopsy often cannot reflect the disease as it progresses, requiring new biopsy samples to determine a change of treatment. All carcinomas, about 80% of all cancer, shed tumor cells into the circulation, most often at the later stages when treatment is more critical. These circulating tumor cells (CTCs) are the cause of metastasis, and can be isolated from patient blood to serve as ``liquid biopsy''. These CTCs contain a valuable trove of information that help both patient and clinician understand disease status. In addition to counting the number of CTCs (known to be a prognostic indicator of survival), CTCs can provide biomarker information such as protein expressions and gene mutations, amplifications, and translocations. This information can be used to determine treatment. During treatment, the number of intact and apoptotic CTCs can be measured on a repeated basis to measure the patient's response to treatment and disease progression. Following treatment, liquid biopsy can be repeated at regular intervals to watch for relapse. Methods to isolate CTCs can be grouped into three categories: i) immunocapture based on surface markers of CTCs, ii) size exclusion based on CTC size, typically larger than blood cells, and iii) negative selection utilizing red blood cell lysis, white blood cell depletion or FICOLL. Various implementations of the CTC isolation methods will be presented.
Heim, Albert
2016-01-01
Summary Background The performance of the multiplex Procleix Ultrio Elite assay as individual donor nucleic acid test (ID-NAT) for the detection of HIV-1, HIV-2, HCV, and HBV was evaluated in a retrospective, single center study. Methods ID-NAT results of 21,181 blood donors, 984 tissue donors, 293 hematopoietic stem cell donors and 4 organ donors were reviewed in synopsis with results of serological screening and additional discriminatory and repetitive NAT in case of positive donors. Results Specificity of the initial Procleix Ultrio Elite assay was 99.98% and after discriminatory testing 100.00%. Initially invalid results were observed in 75 of 21,181 blood donors (0.35%) but 16 of 984 tissue donors (1.62%, p < 0.001) which included non-heart-beating (‘cadaveric’) donors. All these had valid negative ID-NAT results after repeated testing or testing of 1:5 diluted specimens in case of tissue donors. Occult hepatitis B (defined here as HBV DNAemia without HBsAg detection) was demonstrated by ID-NAT in two anti-HBc-positive tissue donors and suspected in two other tissue donors, where a definite diagnosis was not achieved due to the insufficient sample volumes available. Conclusion The Procleix Ultrio Elite assay proved to be specific, robust and rapid. Therefore, routine ID-NAT may also be feasible for organ and granulocyte donors. PMID:27403089
Kulvatunyou, Narong; Joseph, Bellal; Friese, Randall S; Green, Donald; Gries, Lynn; O'Keeffe, Terence; Tang, Andy L; Wynne, Julie L; Rhee, Peter
2012-12-01
Small 14F pigtail catheters (PCs) have been shown to drain air quite well in patients with traumatic pneumothorax (PTX). But their effectiveness in draining blood in patients with traumatic hemothorax (HTX) or hemopneumothorax (HPTX) is unknown. We hypothesized that 14F PCs can drain blood as well as large-bore 32F to 40F chest tubes. We herein report our early case series experience with PCs in the management of traumatic HTX and HPTX. We prospectively collected data on all bedside-inserted PCs in patients with traumatic HTX or HPTX during a 30-month period (July 2009 through December 2011) at our Level I trauma center. We then compared our PC prospective data with our trauma registry-derived retrospective chest tube data (January 2008 through December 2010) at our center. Our primary outcome of interest was the initial drainage output. Our secondary outcomes were tube duration, insertion-related complications, and failure rate. For our statistical analysis, we used the unpaired Student's t-test, χ test, and Wilcoxon rank-sum test; we defined significance by a value of p < 0.05. A total of 36 patients received PCs, and 191 received chest tubes. Our PC group had a higher rate of blunt mechanism injuries than our chest tube group did (83 vs. 62%; p = 0.01). The mean initial output was similar between our PC group (560 ± 81 mL) and our chest tube group (426 ± 37 mL) (p = 0.13). In the PC group, the tube was inserted later (median, Day 1; interquartile range, Days 0-3) than the tube inserted in our chest tube group (median, Day 0; interquartile range, Days 0-0) (p < 0.001). Tube duration, rate of insertion-related complications, and failure rate were all similar. In our early experience, 14F PCs seemed to drain blood as well as large-bore chest tubes based on initial drainage output and other outcomes studied. In this early phase, we were being selective in inserting PCs in only stable blunt trauma patients, and PCs were inserted at a later day from the time of the initial evaluation. In the future, we will need a larger sample size and possibly a well-designed prospective study. Therapeutic study, level V.
Simplified Pan-species Real-time PCR-based Detection of Plasmodium Spp. in Blood Smear.
Hassanpour, Gholamreza; Mirhendi, Hossein; Mohebali, Mehdi; Raeisi, Ahmad; Zeraati, Hojjat; Keshavarz, Hossein
2016-01-01
We aimed to quicken and simplify the detection of Plasmodium in blood samples by developing and testing a pan- Plasmodium real-time PCR for accurate screening of individuals suspected of malaria. A single primer/probe set for pan-species Plasmodium -specific real time PCR targeting a conserved region of the small subunit 18S ribosomal DNA was designed and evaluated for rapid diagnosis and screening of malaria infections using dried blood smears. FTA cards were used for rapid and simple DNA extraction. The primers and probes showed a positive response with the DNA extracted from bloods infected with P. falciparum and P. vivax but not with DNA extracted from various smears from uninfected blood samples. Seven positive cases positive by both microscopy and nested PCR were found among 280 blood samples taken from in South and Southeast Iran. Five samples were identified as positive for P. vivax and two as positive for P. falciparum . All positive samples were positive by real-time PCR. Furthermore, all 38-blood samples positive by microscopy were positive by real-time PCR. No microscopy-negative samples were positive by real-time PCR. By using a simple FTA card for DNA extraction and by application of the real-time PCR developed in this study, sensitivity similar to nested-PCR and microscopy was achieved. This format simplifies the detection of Plasmodium in large numbers of samples.
Peiffer-Smadja, Nathan; Ouedraogo, Ramatou; D'Ortenzio, Eric; Cissé, Papa Ndiaga; Zeggani, Zahra; Beavogui, Abdoul Habib; Faye, Sylvain Landry; Le Marcis, Frédéric; Yazdanpanah, Yazdan; Nguyen, Vinh-Kim
2017-05-02
There are few data on the acceptability of vaccination or blood sampling during Ramadan fasting month in Muslim countries. This could impact vaccination campaigns, clinical trials or healthcare during Ramadan. Using a semi-structured questionnaire, we conducted a cross-sectional study on 201 practising Muslims and 10 religious leaders in Conakry, Guinea in the wake of the recent epidemic Ebola epidemic. Acceptability of vaccination and blood sampling during Ramadan were investigated as well as reasons for refusal. Vaccination was judged acceptable during Ramadan by 46% (93/201, 95% CI 0.40-0.53) of practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) of religious leaders (p=0.11). Blood sampling was judged acceptable during Ramadan by 54% (108/201, 95% CI 0.47-0.60) of practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) of religious leaders (p=0.19). The percentage of participants that judged both blood sampling and vaccination acceptable during Ramadan was 40% (81/201, 95% CI 0.34-0.47) for practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) for religious leaders (p=0.048). The most common reasons for refusal of vaccination or blood sampling were that nothing should enter or leave the body during Ramadan (43%), that adverse events could lead to breaking the fast (32%), that blood should not be seen during Ramadan (9%) and that the Quran explicitly forbids it (9%). Although most Muslims leaders and scientists consider that injections including immunization and blood sampling should be authorized during Ramadan, many Muslims in our study judged vaccination or blood sampling unacceptable when fasting. Widely available recommendations on healthcare during Ramadan would be useful to inform Muslims. Copyright © 2017. Published by Elsevier Ltd.
Grabarczyk, Piotr; Brojer, Ewa; Nasiłowska, Barbara; Mariańska, Bozena
2006-09-01
It is recommended that all patients after allogeneic hematopoietic stem cell transplantation (alloHSCT) should be monitored for CMV infection markers. The aim of the study was to check the usefulness of quantitative DNA CMV monitoring after alloHSCT. DNA CMV was tested by real-time PCR in sera and blood samples twice a week until 30th day after alloHSCT thereafter, once a week until 100th day and then, once every 2-3 weeks. 832 samples from 16 patients were tested. All patients were anti-CMV positive or/and received stem cells from seropositive donors. Introduction of antiviral treatment was based on initial viral load and its rate of increase. DNA CMV was detected in 13/16 patients; in 3 before 30h day after allo HSCT (group I) and in 10 (group II) after 30th day. In all patients from group I clinical symptoms were observed and DNA CMV was detected in sera and blood samples. Peak viral load was 2490-34 620 geq/ml. Although antiviral treatment was applied, reinfection was observed and infection lasted from 28 to 91 days. In 6 group II patients, clinical symptoms were observed and DNA CMV in sera and blood was detected for 16-56 days, DNA CMV peak load was 100-8950 geq/ml. In the remaining 4 patients, no clinical symptoms were observed--DNA CMV was detected in blood only for 7 to 14 days. In one patient with peak viral load 10,540 geq/ml, antiviral treatment was applied. In 3 with viral load of 400-2000 geq/ml, treatment was not introduced. The quantitative DNA CMV results were taken into account before the change of antiviral drugs for more effective drugs and the decrease of drug dose due to side effects. Application of quantititative DNA CMV testing allowed to optimise antiviral drug administration in immunosupressed patients after alloHSCT
Leuthold, Luc Alexis; Heudi, Olivier; Déglon, Julien; Raccuglia, Marc; Augsburger, Marc; Picard, Franck; Kretz, Olivier; Thomas, Aurélien
2015-02-17
Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 μL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.
Podda, Gian Marco; Pugliano, Mariateresa; Femia, Eti Alessandra; Mezzasoma, Anna Maria; Gresele, Paolo; Carpani, Giovanni; Cattaneo, Marco
2012-07-01
Spuriously low platelet counts (PCs) can be observed in normal blood samples anticoagulated with ethylenediamine tetra-acetic acid (EDTA)and, much less frequently, with citrate-tris-pyridossalphosphate (CPT),due to time-dependent in vitro platelet agglutination. Accuracy in PC determination is essential as PC is one of the parameters that usually guides treatment for thrombocytopenic patients. PCs of 93 thrombocy to penic patients were measured in EDTA- or CPT-anticoagulated blood samples immediately after sampling (t0) and 90 min (t90) after storage at room temperature. The presence of platelet agglutinates in blood samples was determined by examining blood smears using optical microscopy.PCs decreased at t90 with both anticoagulants. Platelet agglutinates were present at t90 in 27% of EDTA-samples vs. 2% of CPT-samples with decreased PCs (P < 0.001). Based on PCs in EDTA-samples, 15 patients (16%) shifted from a lower bleeding risk at t0 to a higher bleeding risk category at t90 (P 5 0.019), compared to 5 (5%) patients, based on PCs in CPT-samples. Therefore, time-dependent in vitro platelet agglutination in EDTA-blood samples may cause underestimation of PCs in thrombocytopenic patients, possibly leading to improper management.
Jacobs, V R; Niemeyer, M; Gottschalk, N; Schneider, K T; Kiechle, M
2005-12-01
Private umbilical cord blood (UCB) banking after delivery has increased over the last decade. For adult/somatic stem cell research UCB is an essential source of stem cells and researchers question if the number of UCB samples for research might be reduced by private banking. A survey among seven private blood banks in Germany and analysis and comparison of the number of UCB samples donated for research within the STEMMAT project with private blood banking were performed from 03/2003 to 06/2005 at the Frauenklinik (OB/GYN), Technical University Munich, Germany. Within 27.5 months 1,551 UCB samples were collected for research purposes; the effective recruitment rate was higher than expectations at an effective 66.2 %. Private UCB banking [n = 24] was distributed among three cord blood banks [n = 16, 6 and 4]. The rate of private blood banking was 0.99 % for all deliveries, thus reducing the effective rate for research purpose by only 1.5 %. Under the assumption of active and successful recruitment of scientific UCB samples, private blood banking does not significantly reduce this rate and therefore is a negligible rival in the competition for sufficient numbers of UCB samples for research.
DNA quality and quantity from up to 16 years old post-mortem blood stored on FTA cards.
Rahikainen, Anna-Liina; Palo, Jukka U; de Leeuw, Wiljo; Budowle, Bruce; Sajantila, Antti
2016-04-01
Blood samples preserved on FTA cards offer unique opportunities for genetic research. DNA recovered from these cards should be stable for long periods of time. However, it is not well established as how well the DNA stored on FTA card for substantial time periods meets the demands of forensic or genomic DNA analyses and especially so for from post-mortem (PM) samples in which the quality can vary upon initial collection. The aim of this study was to evaluate the time-dependent degradation on DNA quality and quantity extracted from up to 16 years old post-mortem bloodstained FTA cards. Four random FTA samples from eight time points spanning 1998 to 2013 (n=32) were collected and extracted in triplicate. The quantity and quality of the extracted DNA samples were determined with Quantifiler(®) Human Plus (HP) Quantification kit. Internal sample and sample-to-sample variation were evaluated by comparing recovered DNA yields. The DNA from the triplicate samplings were subsequently combined and normalized for further analysis. The practical effect of degradation on DNA quality was evaluated from normalized samples both with forensic and pharmacogenetic target markers. Our results suggest that (1) a PM change, e.g. blood clotting prior to sampling, affects the recovered DNA yield, creating both internal and sample-to-sample variation; (2) a negative correlation between the FTA card storage time and DNA quantity (r=-0.836 at the 0.01 level) was observed; (3) a positive correlation (r=0.738 at the level 0.01) was found between FTA card storage time and degradation levels. However, no inhibition was observed with the method used. The effect of degradation was manifested clearly with functional applications. Although complete STR-profiles were obtained for all samples, there was evidence of degradation manifested as decreased peak heights in the larger-sized amplicons. Lower amplification success was notable with the large 5.1 kb CYP2D6 gene fragment which strongly supports degradation of the stored samples. According to our results, DNA stored on FTA cards is rather stable over a long time period. DNA extracted from this storage medium can be used as human identification purposes as the method used is sufficiently sensitive and amplicon sizes tend to be <400 bp. However, DNA integrity was affected during storage. This effect should be taken into account depending on the intended application especially if high quality DNA and long PCR amplicons are required. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Reduction in Blood Culture Contamination Through Use of Initial Specimen Diversion Device
Cavalieri, R. Jennifer; Marolf, Cole; Lyden, Elizabeth
2017-01-01
Abstract Background. Blood culture contamination is a clinically significant problem that results in patient harm and excess cost. Methods. In a prospective, controlled trial at an academic center Emergency Department, a device that diverts and sequesters the initial 1.5–2 mL portion of blood (which presumably carries contaminating skin cells and microbes) was tested against standard phlebotomy procedures in patients requiring blood cultures due to clinical suspicion of serious infection. Results. In sum, 971 subjects granted informed consent and were enrolled resulting in 904 nonduplicative subjects with 1808 blood cultures. Blood culture contamination was significantly reduced through use of the initial specimen diversion device™ (ISDD) compared to standard procedure: (2/904 [0.22%] ISDD vs 16/904 [1.78%] standard practice, P = .001). Sensitivity was not compromised: true bacteremia was noted in 65/904 (7.2%) ISDD vs 69/904 (7.6%) standard procedure, P = .41. No needlestick injuries or potential bloodborne pathogen exposures were reported. The monthly rate of blood culture contamination for all nurse-drawn and phlebotomist-drawn blood cultures was modeled using Poisson regression to compare the 12-month intervention period to the 6 month before and after periods. Phlebotomists (used the ISDD) experienced a significant decrease in blood culture contamination while the nurses (did not use the ISDD) did not. In sum, 73% of phlebotomists completed a post-study anonymous survey and widespread user satisfaction was noted. Conclusions. Use of the ISDD was associated with a significant decrease in blood culture contamination in patients undergoing blood cultures in an Emergency Department setting. Clinical Trials Registration. NCT02102087. PMID:28379370
Thompson, Marcella Remer; Burdon, Andrea; Boekelheide, Kim
2013-01-01
Prior to 1978, the exteriors of Rhode Island's municipal water towers were painted with lead-containing paint. Over time, this lead-containing paint either flaked-off or was mechanically removed and deposited on adjacent residential properties. Residents challenged inconsistencies across state agencies and federal requirements for collecting and analyzing soil samples. The purpose of this case study was to evaluate the efficacy of Rhode Island Department of Health (RIDOH) soil sampling regulations in determining the extent of lead contamination on residential properties using real world data. Researchers interviewed key government personnel, reviewed written accounts of events and regulations, and extracted and compiled lead data from environmental soil sampling on 31 residential properties adjacent to six municipal water towers. Data were available for 498 core samples. Approximately 26% of the residential properties had lead soil concentrations >1,000 mg/kg. Overall, lead concentration was inversely related to distance from the water tower. Analysis indicated that surface samples alone were insufficient to classify a property as “lead safe”. Potential for misclassification using RIDOH regulations was 13%. For properties deemed initially “lead free”, the total number of samples was too few to analyze. Post-remediation lead-soil concentrations suggest the extent of lead contamination may have been deeper than initially determined. Additional data would improve the ability to draw more meaningful and generalized conclusions. Inconsistencies among regulatory agencies responsible for environmental health obfuscate transparency and erode the public's trust in the regulatory process. Recommendations for improvement include congruency across departmental regulations and specific modifications to soil sampling regulations reflective of lowered CDC reference blood lead value for children 1 to 5 years old (5μg/dL). While scientific research informed the initial development of these environmental health policies and regulations, practice-based evidence did not support their efficacy in context of real world practice. PMID:24055667
2012-04-26
ISS030-E-257690 (26 April 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, prepares for IMMUNE venous blood sample draws in the Columbus laboratory of the International Space Station. Following the blood draws, the samples were temporarily stowed in the Minus Eighty Laboratory Freezer for ISS 1 (MELFI-1) and later packed together with saliva samples on the Soyuz TMA-22 for return to Earth for analysis.
In vitro production of GHB in blood and serum samples under various storage conditions.
Zörntlein, S W; Kopp, A; Becker, J; Kaufmann, T J; Röhrich, J; Urban, R
2012-01-10
The in vitro production of GHB was observed in freshly collected, untreated whole blood samples using glass BD-Vacutainers and polypropylene S-monovettes. GHB concentrations were determined daily over a period of one week and after 3, 6 and 9 weeks again. Furthermore, the GHB concentration in 40 untreated random whole blood samples stored at 4°C for a longer period of time (10 samples 12 month, 10 samples 24 month and 20 samples 36 month) was also determined. For comparison, the in vitro production of GHB in freshly collected and prepared serum samples was observed. GHB serum concentrations were determined three times over a period of one week and once again after six weeks. Sample preparation was performed by means of methanolic extraction following the precipitation of whole blood and serum samples. A methanolic standard calibration was done in a low range of 0.005-0.1 μg/mL (LOD: 0.004, LLOQ: 0.013). For quantification a spiked blood bank serum with a determined GHB concentration of 0.09 μg/mL was used. Corrected calibrations in the range of 0.09-5.09 μg/mL were used (LOD: 0.08 μg/mL, LLOQ: 0.30 μg/mL), recovery: 91.3% (high level: 4.09 μg/mL) 50.5% (low level: 0.19 μg/mL). Relevant elevation of GHB was observed in all whole blood samples stored in liquid form (4°C or room temperature). In two of the 40 whole blood samples stored over a longer period of time at 4°C, GHB concentrations in the range of 13 μg/mL were even determined. These findings constitute grounds for caution. Even a GHB cut-off level of 5 μg/mL cannot be considered as "absolutely positive" proof of a case of exogenous administration, at least in untreated liquid blood samples in long time storage. However, no significant elevations of GHB were otherwise observed in any of the serum samples independently of storage temperature nor in the whole blood samples that were frozen for storage. The results suggest that the cut-off for exogenous GHB of 5 μg/mL could be lowered significantly, with the consequence of winning valuable time for the potential victim, but only if serum is collected for GHB determination or if the whole blood sample is frozen immediately after collection and the procedure well documented. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Improving blood transfusion practice by regular education in the United Arab Emirates.
Sajwani, F H
2012-07-01
A cross-match to transfused unit ratio of less than 2.0 is frequently used to assess performance in many hospital blood banks. This brief report was initiated to evaluate the practice at a local hospital and to emphasize the importance of regular educational sessions to improve blood transfusion practice. Retrospective data on cross-match : transfused (C : T) ratio of all departments was collected and educational sessions were given to improve practice. Thereafter, a new set of data was collected and change in practice was assessed. Initial data showed total (C : T) ratio of 1.95. After medical staff education, analysis showed clinically significant improvement in blood utilization practice with a (C : T) ratio of 1.60. This brief report indicates the importance of regular physician education, the potential role of blood transfusion committee, and the need to implement clear guidelines for blood transfusion. © 2012 American Association of Blood Banks.
Algorithm-based arterial blood sampling recognition increasing safety in point-of-care diagnostics.
Peter, Jörg; Klingert, Wilfried; Klingert, Kathrin; Thiel, Karolin; Wulff, Daniel; Königsrainer, Alfred; Rosenstiel, Wolfgang; Schenk, Martin
2017-08-04
To detect blood withdrawal for patients with arterial blood pressure monitoring to increase patient safety and provide better sample dating. Blood pressure information obtained from a patient monitor was fed as a real-time data stream to an experimental medical framework. This framework was connected to an analytical application which observes changes in systolic, diastolic and mean pressure to determine anomalies in the continuous data stream. Detection was based on an increased mean blood pressure caused by the closing of the withdrawal three-way tap and an absence of systolic and diastolic measurements during this manipulation. For evaluation of the proposed algorithm, measured data from animal studies in healthy pigs were used. Using this novel approach for processing real-time measurement data of arterial pressure monitoring, the exact time of blood withdrawal could be successfully detected retrospectively and in real-time. The algorithm was able to detect 422 of 434 (97%) blood withdrawals for blood gas analysis in the retrospective analysis of 7 study trials. Additionally, 64 sampling events for other procedures like laboratory and activated clotting time analyses were detected. The proposed algorithm achieved a sensitivity of 0.97, a precision of 0.96 and an F1 score of 0.97. Arterial blood pressure monitoring data can be used to perform an accurate identification of individual blood samplings in order to reduce sample mix-ups and thereby increase patient safety.
Pasanisi, Eugenia; Cortés-Gómez, Adriana A; Pérez-López, Marcos; Soler, Francisco; Hernández-Moreno, David; Guerranti, Cristiana; Martellini, Tania; Fuentes-Mascorro, Gisela; Romero, Diego; Cincinelli, Alessandra
2016-12-01
Lepidochelys olivacea is the most abundant and globally distributed sea turtle species in the world and thus, monitoring this species for persistent organic pollutants, such as perfluorinated chemicals, is fundamental for their protection. This study was the first to evaluate the occurrence of five PFCAs (PFOA, PFNA, PFDA, PFUnA, PFDoA) in liver and blood samples of Olive Ridley turtle population from the Escobilla beach (Oaxaca, Mexico). PFDA and PFUnA were the predominant PFCs in blood samples (detected in 93% and 84% of samples, respectively) and were also present in the highest concentrations. Liver samples showed higher PFCA concentrations than whole blood samples, with PFNA and PFDA the most abundant PFCs congeners in liver samples, detected in 65% and 47% of the samples, respectively. The measured levels of contaminants in the blood samples of Lepidochelys olivacea sea turtles were compared to the levels reported in the literature for other turtle species. While linear significant correlations between PFNA, PFDA and PFUnA concentrations in blood samples and curved carapace lengths were determined, no correlation was found for PFOA, supporting the hypothesis that sea turtles could have a higher ability to eliminate this perfluorinated chemical from their blood than other PFCAs. However, we do not know if the concentrations are species or sampling areas dependent. Copyright © 2016 Elsevier B.V. All rights reserved.
Stability of carboxyhemoglobin in stored and mailed blood samples.
Hampson, Neil B
2008-02-01
Elevated blood carboxyhemoglobin (COHb) levels are used to confirm a clinical diagnosis of exposure to carbon monoxide (CO) and, in some instances, assess severity of poisoning. However, many hospital laboratories cannot measure COHb because they do not have CO-oximeters. In such instances, blood samples are often sent to outside laboratories or with a transported patient for measurement at the receiving hospital. This study was conducted to assess the stability of COHb in stored and mailed blood samples anticoagulated with heparin. Adult human blood was drawn into standard sample tubes anticoagulated with sodium heparin. Carbon monoxide gas was infused to raise the COHb level to 25% to 35%. Samples were then refrigerated or stored at room temperature, and serial COHb determinations were performed for 28 days. Additional samples were measured after being mailed locally or across the United States and back. No significant changes in COHb levels were seen in samples stored either in refrigeration or at room temperature over a period of 28 days or in samples shipped without refrigeration locally or across the United States. Carboxyhemoglobin levels in whole blood samples anticoagulated with heparin are stable with or without refrigeration for up to 4 weeks. If COHb measurement capability is not available, such samples may be shipped or transported with patients with confidence that the COHb level will be stable when measured at a later time.
Ernst, D; Clerc, J; Decullier, E; Gavanier, G; Dupuis, O
2012-10-01
At birth, evaluation of neonatal well-being is crucial. It is though important to perform umbilical cord blood gas analysis, and then to analyze the samples. We wanted to establish the feasibility and reliability of systematic umbilical cord blood sampling in a French labour ward. Study of systematic umbilical cord blood gas analysis was realized retrospectively from 1000 consecutive deliveries. We first established the feasibility of the samples. Feasibility was defined by the ratio of complete cord acid-base data on the number of deliveries from alive newborns. Afterwards, we established the reliability on the remaining cord samples. Reliability was the ratio of samples that fulfilled quality criteria defined by Westgate et al. and revised by Kro et al., on the number of complete samples from alive newborns. At last, we looked for factors that would influence these results. The systematic umbilical cord blood sample feasibility reached 91.6%, and the reliability reached 80.7%. About the delivery mode, 38.6% of emergency caesarians (IC 95% [30.8-46.3]; P<0.0001) led to non-valid samples, when only 11.3% of programmed caesarians (IC 95% [4.3-18.2]; P<0.0001) led to non-valid samples. Umbilical cord blood analysis were significantly less validated during emergency caesarians. Realization of systematic cord blood gas analysis was followed by 8.4% of incomplete samples, and by 19.3% that were uninterpretable. Training sessions should be organized to improve the feasibility and reliability, especially during emergency caesarians. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Kennedy, Laura; Vass, J. Keith; Haggart, D. Ross; Moore, Steve; Burczynski, Michael E.; Crowther, Dan; Miele, Gino
2008-01-01
Peripheral blood as a surrogate tissue for transcriptome profiling holds great promise for the discovery of diagnostic and prognostic disease biomarkers, particularly when target tissues of disease are not readily available. To maximize the reliability of gene expression data generated from clinical blood samples, both the sample collection and the microarray probe generation methods should be optimized to provide stabilized, reproducible and representative gene expression profiles faithfully representing the transcriptional profiles of the constituent blood cell types present in the circulation. Given the increasing innovation in this field in recent years, we investigated a combination of methodological advances in both RNA stabilisation and microarray probe generation with the goal of achieving robust, reliable and representative transcriptional profiles from whole blood. To assess the whole blood profiles, the transcriptomes of purified blood cell types were measured and compared with the global transcriptomes measured in whole blood. The results demonstrate that a combination of PAXgene™ RNA stabilising technology and single-stranded cDNA probe generation afforded by the NuGEN Ovation RNA amplification system V2™ enables an approach that yields faithful representation of specific hematopoietic cell lineage transcriptomes in whole blood without the necessity for prior sample fractionation, cell enrichment or globin reduction. Storage stability assessments of the PAXgene™ blood samples also advocate a short, fixed room temperature storage time for all PAXgene™ blood samples collected for the purposes of global transcriptional profiling in clinical studies. PMID:19578521
Jin, Ling; Escher, Beate I; Limpus, Colin J; Gaus, Caroline
2015-11-01
Conventional target analysis of biological samples such as blood limits our ability to understand mixture effects of chemicals. This study aimed to establish a rapid passive sampling technique using the polymer polydimethylsiloxane (PDMS) for exhaustive extraction of mixtures of neutral organic chemicals accumulated in blood of green turtles, in preparation for screening in in vitro bioassays. We designed a PDMS-blood partitioning system based on the partition coefficients of chemicals between PDMS and major blood components. The sampling kinetics of hydrophobic test chemicals (polychlorinated dibenzo-p-dioxins; PCDDs) from blood into PDMS were reasonably fast reaching steady state in <96 h. The geometric mean of the measured PDMS-blood partition coefficients for PCDDs, polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) was 14 L blood kg PDMS(-1) and showed little variability (95% confidence interval from 8.4 to 29) across a wide range of hydrophobicity (logKow 5.7-8.3). The mass transfer of these chemicals from 5 mL blood into 0.94 g PDMS was 62-84%, which is similar to analytical recoveries in conventional solvent extraction methods. The validated method was applied to 15 blood samples from green turtles with known concentrations of PCDD/Fs, dioxin-like PCBs, PBDEs and organochlorine pesticides. The quantified chemicals explained most of the dioxin-like activity (69-98%), but less than 0.4% of the oxidative stress response. The results demonstrate the applicability of PDMS-based passive sampling to extract bioaccumulative chemicals from blood as well as the value of in vitro bioassays for capturing the combined effects of unknown and known chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.
Digital questionnaire platform in the Danish Blood Donor Study.
Burgdorf, K S; Felsted, N; Mikkelsen, S; Nielsen, M H; Thørner, L W; Pedersen, O B; Sørensen, E; Nielsen, K R; Bruun, M T; Werge, T; Erikstrup, C; Hansen, T; Ullum, H
2016-10-01
The Danish Blood Donor Study (DBDS) is a prospective, population-based study and biobank. Since 2010, 100,000 Danish blood donors have been included in the study. Prior to July 2015 all participating donors had to complete a paper-based questionnaire. Here we describe the establishment of a digital tablet-based questionnaire platform implemented in blood bank sites across Denmark. The digital questionnaire was developed using the open source survey software tool LimeSurvey. The participants accesses the questionnaire online with a standard SSL encrypted HTTP connection using their personal civil registration numbers. The questionnaire is placed at a front-end web server and a collection server retrieves the completed questionnaires. Data from blood samples, register data, genetic data and verification of signed informed consent are then transferred to and merged with the questionnaire data in the DBDS database. The digital platform enables personalized questionnaires, presenting only questions relevant to the specific donor by hiding unneeded follow-up questions on screening question results. New versions of questionnaires are immediately available at all blood collection facilities when new projects are initiated. The digital platform is a faster, cost-effective and more flexible solution to collect valid data from participating donors compared to paper-based questionnaires. The overall system can be used around the world by the use of Internet connection, but the level of security depends on the sensitivity of the data to be collected. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Metabolic effects of green tea and of phases of weight loss.
Diepvens, K; Kovacs, E M R; Vogels, N; Westerterp-Plantenga, M S
2006-01-30
The effect of ingestion of green tea (GT) extract along with a low-energy diet (LED) on health-related blood parameters, and the relationships among changes in metabolic parameters and phases of weight loss were assessed. A double-blind, placebo-controlled, parallel design was used. 46 female subjects (BMI 27.7+/-1.8 kg/m(2)) were fed in energy balance from days 1 to 3, followed by a LED with GT (n=23) or placebo (PLAC, n=23) from days 4 to 87. The LED-period consisted of a phase 1 of 4 weeks (days 4-32) followed by a phase 2 of 8 weeks (days 32-87). Body composition and fasting blood samples were determined on days 4, 32 and 87. No significant differences were observed between the blood parameters of the PLAC and GT group. In phase 1 compared to phase 2 the rate of weight loss was 0.09+/-0.05 kg/day vs. 0.03+/-0.03 kg/day (p<0.001); Fat free mass (FFM) was 21% of weight loss in phase 1 vs. 7% in phase 2 (ns). Surprisingly, favourable changes in free fatty acids, triacylglycerol, beta-hydroxybutyrate, glucose and total cholesterol in phase 1 were reversed in phase 2 (p<0.01). Taken together, GT supplementation during a LED had no effect on health-related blood parameters. Initial improvements in several blood measures at day 32 were reversed by day 87, despite continued weight loss. Modest weight loss improved HDL cholesterol and blood pressure.
Caron, Alexis; Lelong, Christine; Bartels, T; Dorchies, O; Gury, T; Chalier, Catherine; Benning, Véronique
2015-08-01
As a general practice in rodent toxicology studies, satellite animals are used for toxicokinetic determinations, because of the potential impact of serial blood sampling on toxicological endpoints. Besides toxicological and toxicokinetic determinations, blood samples obtained longitudinally from a same animal may be used for the assessment of additional parameters (e.g., metabolism, pharmacodynamics, safety biomarkers) to maximize information that can be deduced from rodents. We investigated whether removal of up to 6 × 200 μL of blood over 24h can be applied in GLP rat toxicology studies without affecting the scientific outcome. 8 week-old female rats (200-300 g) were dosed for up to 1 month with a standard vehicle and subjected or not (controls) to serial blood sampling for sham toxicokinetic/ancillary determinations, using miniaturized methods allowing collection of 6 × 50, 100 or 200 μL over 24h. In-life endpoints, clinical pathology parameters and histopathology of organs sensitive to blood volume reduction were evaluated at several time points after completion of sampling. In sampled rats, minimal and reversible changes in red blood cell mass (maximally 15%) and subtle variations in liver enzymes, fibrinogen and neutrophils were not associated with any organ/tissue macroscopic or microscopic correlate. Serial blood sampling (up to 6 × 200 μL over 24h) is compatible with the assessment of standard toxicity endpoints in adult rats. Copyright © 2015 Elsevier Inc. All rights reserved.
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...
Spicher, G; Peters, J
1991-05-01
The experiments were performed using frosted glass as carrier with its surface being contaminated with whole blood containing Staphylococcus aureus as test organism. At the time of sampling, a heparin preparation was added to the blood to prevent premature coagulation. After addition of the staphylococci, coagulation was initiated by means of a heparin antagonist. 10, 25, 50, 100, and 150 microliters, respectively, of the blood were homogeneously spread on rectangular test areas of 10 x 20 mm. After the blood had coagulated, each of the test objects was placed in 15 ml of the solution (20 degrees C) containing the active ingredient tested for 60 min. After that, the test objects were removed from the disinfectant and, in order to inactivate any adhering active components, treated with a neutralizing solution of suitable composition. The number of viable germs (colony-forming units) was determined quantitatively. The blood samples were ground together with quartz sand. Aliquots of the diluted suspensions were mixed with molten agar medium. The plates then were incubated at 37 degrees C over a period of 14 days. The relative number of viable germs (N/No) per test object was calculated from the number of colonies. Plotting of the microbicidal effects obtained (log N/No] versus the concentration of the active substance (see Figs. 1-3) yielded curves differing in some characteristics as e.g. curvature, slope of the lower curve section (log N/No). less than -3), concentration range according to the layer thickness of the contamination. To visualize the reduction of the efficacy of the respective disinfectants caused by blood, the concentrations of active components were determined which are necessary to achieve a microbicidal effect of log (N/No) = -4. These concentrations were plotted versus the amounts of blood per test area (Fig. 4). The resulting curve for formaldehyde was slightly U-shaped. With a raising amount of blood, the concentration required slightly decreased in the beginning and increased again from an amount of ca. 100 microliter blood per test area. For all other active substances, the required concentration of these substances increased with the amount of blood used. The curve obtained for ethanol exhibited the lowest slope. The slope of the curves increased in the following order: ethanol, m-cresol, peracetic acid, chloramine T, glutardialdehyde, benzyldimethyldodecylammoniumbromide. The curves for chloramine T and glutardialdehyde nearly paralleled each other.(ABSTRACT TRUNCATED AT 400 WORDS)
Ohlsson, Pelle; Petersson, Klara; Augustsson, Per; Laurell, Thomas
2018-06-14
Sepsis is a common and often deadly systemic response to an infection, usually caused by bacteria. The gold standard for finding the causing pathogen in a blood sample is blood culture, which may take hours to days. Shortening the time to diagnosis would significantly reduce mortality. To replace the time-consuming blood culture we are developing a method to directly separate bacteria from red and white blood cells to enable faster bacteria identification. The blood cells are moved from the sample flow into a parallel stream using acoustophoresis. Due to their smaller size, the bacteria are not affected by the acoustic field and therefore remain in the blood plasma flow and can be directed to a separate outlet. When optimizing for sample throughput, 1 ml of undiluted whole blood equivalent can be processed within 12.5 min, while maintaining the bacteria recovery at 90% and the blood cell removal above 99%. That makes this the fastest label-free microfluidic continuous flow method per channel to separate bacteria from blood with high bacteria recovery (>80%). The high throughput was achieved by matching the acoustic impedance of the parallel stream to that of the blood sample, to avoid that acoustic forces relocate the fluid streams.
Pharmacokinetics of isotretinoin during repetitive dosing to patients.
Brazzell, R K; Vane, F M; Ehmann, C W; Colburn, W A
1983-01-01
The multiple dose pharmacokinetics of isotretinoin and its major blood metabolite, 4-oxo-isotretinoin, were studied in 10 patients with cystic acne and 11 patients with various keratinization disorders. Blood samples were obtained at predetermined times following the first dose, interim doses and the final dose. Blood concentrations of isotretinoin and 4-oxo-isotretinoin were measured by a specific and sensitive HPLC method. A lag time was usually observed prior to the onset of absorption following oral administration of the drug in a soft elastic gelatin capsule. Absorption then proceeded rapidly and maximum blood concentrations usually occurred within 4 h of drug administration. The harmonic mean half-life for the elimination of isotretinoin by the cystic acne patients was approximately 10 h after the initial dose and did not change significantly following 25 days of 40 mg b.i.d. dosing. Steady-state blood concentrations remained relatively constant after the fifth day of dosing. The harmonic mean elimination half-life in the patients with various disorders of keratinization was about 16 h. The results of the 2 studies suggest that no significant changes in the pharmacokinetics of isotretinoin occur during multiple dosing and that the multiple dose pharmacokinetic profile is predictable and can be described using a linear pharmacokinetic model. This suggests that the steady-state concentrations of isotretinoin can be predicted from single dose data.
Flores-Chavez, María; Cruz, Israel; Nieto, Javier; Gárate, Teresa; Navarro, Miriam; Pérez-Ayala, Ana; López-Vélez, Rogelio
2012-01-01
Trypanosoma cruzi infection is an imported parasitic disease in Spain, and the majority of infected individuals are in the chronic phase of the disease. This study evaluated the sensitivity and specificity of the Operon immunochromatographic test (ICT-Operon; Simple Stick Chagas and Simple Chagas WB [whole blood]; Operon S.A., Spain) for different biological samples. Well-characterized serum samples were obtained from chagasic patients (n = 63), nonchagasic individuals (n = 95), visceral leishmaniasis patients (n = 38), and malaria patients (n = 55). Noncharacterized specimens were obtained from Latin American immigrants and individuals at risk with a clinical and/or epidemiological background: these specimens were recovered serum or plasma samples (n = 450), whole peripheral blood (n = 94), and capillary blood (n = 282). The concordance of the results by enzyme-linked immunosorbent assay and indirect immunofluorescence test was considered to be the “gold standard” for diagnosis. Serum and plasma samples were analyzed by Stick Chagas, and whole blood was analyzed by Simple Chagas WB. The sensitivity and specificity of the ICT-Operon in well-characterized samples were 100% and 97.9%, respectively. No cross-reactivity was found with samples obtained from visceral leishmaniasis patients. In contrast, a false-positive result was obtained in 27.3% of samples from malaria patients. The sensitivities of the rapid test in noncharacterized serum or plasma, peripheral blood, and capillary blood samples were 100%, 92.1%, and 86.4%, respectively, while the specificities were 91.6%, 93.6%, and 95% in each case. ICT-Operon showed variable sensitivity, depending on the kind of sample, performing better when serum or plasma samples were used. It could therefore be used for serological screening combined with any other conventional test. PMID:22761296
Microfluidic, marker-free isolation of circulating tumor cells from blood samples
Karabacak, Nezihi Murat; Spuhler, Philipp S; Fachin, Fabio; Lim, Eugene J; Pai, Vincent; Ozkumur, Emre; Martel, Joseph M; Kojic, Nikola; Smith, Kyle; Chen, Pin-i; Yang, Jennifer; Hwang, Henry; Morgan, Bailey; Trautwein, Julie; Barber, Thomas A; Stott, Shannon L; Maheswaran, Shyamala; Kapur, Ravi; Haber, Daniel A; Toner, Mehmet
2014-01-01
The ability to isolate and analyze rare circulating tumor cells (CTCs) has the potential to further our understanding of cancer metastasis and enhance the care of cancer patients. In this protocol, we describe the procedure for isolating rare CTCs from blood samples by using tumor antigen–independent microfluidic CTC-iChip technology. The CTC-iChip uses deterministic lateral displacement, inertial focusing and magnetophoresis to sort up to 107 cells/s. By using two-stage magnetophoresis and depletion antibodies against leukocytes, we achieve 3.8-log depletion of white blood cells and a 97% yield of rare cells with a sample processing rate of 8 ml of whole blood/h. The CTC-iChip is compatible with standard cytopathological and RNA-based characterization methods. This protocol describes device production, assembly, blood sample preparation, system setup and the CTC isolation process. Sorting 8 ml of blood sample requires 2 h including setup time, and chip production requires 2–5 d. PMID:24577360
Miezan, T.; Doua, F.; Cattand, P.; de Raadt, P.
1991-01-01
The Testryp CATT was performed on dried blood samples on filter-paper and on diluted blood using a microtechnique. This method was applied to both sample collection techniques and was evaluated in parallel with the classical Testryp CATT on whole blood, as described in the instructions provided with the reagents by the manufacturer. A total of 2087 people were tested; 453 samples were tested in the laboratory and 1634 during a field survey in 5 villages of a trypanosomiasis focus in Daloa, Côte d'Ivoire. This study has demonstrated that the Testryp CATT micromethod on either type of sample collection gives results comparable to the Testryp CATT on whole blood. The collection of dried blood samples on filter-paper can be performed by non-specialized staff in trypanosomiasis control programmes of the national health services. In addition, a flask of CATT reagent will allow testing of 6 times more people by the micromethod than by the classical whole-blood method. The micromethod is suitable in the implementation of programmes for the serological surveillance of populations at risk. PMID:1959162
Foo, Lee Kien; McGree, James; Duffull, Stephen
2012-01-01
Optimal design methods have been proposed to determine the best sampling times when sparse blood sampling is required in clinical pharmacokinetic studies. However, the optimal blood sampling time points may not be feasible in clinical practice. Sampling windows, a time interval for blood sample collection, have been proposed to provide flexibility in blood sampling times while preserving efficient parameter estimation. Because of the complexity of the population pharmacokinetic models, which are generally nonlinear mixed effects models, there is no analytical solution available to determine sampling windows. We propose a method for determination of sampling windows based on MCMC sampling techniques. The proposed method attains a stationary distribution rapidly and provides time-sensitive windows around the optimal design points. The proposed method is applicable to determine sampling windows for any nonlinear mixed effects model although our work focuses on an application to population pharmacokinetic models. Copyright © 2012 John Wiley & Sons, Ltd.
Matovic, Milovan D; Jankovic, Slobodan M; Jeremic, Marija; Tasic, Zoran; Vlajkovic, Marina
2009-08-01
In patients receiving (131)I for therapeutic purposes, diuretics are frequently used in an attempt to accelerate elimination of unbound radioiodine, reduce its adverse effects, and shorten the hospital stay. The aims of our study were to investigate the influence of furosemide therapy on urinary excretion of (131)I in patients with differentiated thyroid cancer (DTC), referred to radioiodine ablation after thyroidectomy, and to investigate whether diuretics are useful in daily practice in patients with DTC. Forty-three patients with DTC who had normal renal function and low (131)I uptake in cervical region (3.55 +/- 3.45%) were included in this study. The furosemide (20 mg) and potassium chloride (250 mg) were given orally to 23 patients 3 hours after the (131)I administration, and then q8h for 3 days. Twenty patients did not receive either furosemide or potassium chloride. After (131)I administration, the patients collected their urine for 3 days, and radioactivity of urine sample from each micturition was expressed as percentage of the administered dose. Radioactivity of blood samples was measured after 72 hours, and the values were corrected for decay of (131)I and expressed in relation to the administered dose. Initial whole-body measurement (immediately after (131)I administration) and the whole-body measurement after 72 hours were recorded for all patients. The 72-hour whole-body measurement was corrected for decay of (131)I, and expressed as a percentage of the initial whole-body measurement. Urinary excretion of (131)I was significantly lower in the patients who were taking furosemide and potassium chloride compared with the control group. The whole-body measurements after 72 hours (13.22 +/- 6.55% vs. 8.24 +/- 3.39% of the initial; p < 0.01, respectively) and the blood radioactivity (34.66 +/- 24.84 vs. 11.64 +/- 8.32 cpm/mL per 1 MBq of administered (131)I, p < 0.01) were found to be unexpectedly higher in the patients who were taking furosemide and potassium chloride compared with the control group. Our results demonstrated that furosemide given as an adjuvant medication in patients with DTC causes a significant decrease in urinary excretion of radioiodine and its higher blood concentration. Therefore, furosemide should not be recommended as an adjuvant therapy to radioiodine ablation in patients with DTC previously iodine depleted by low-iodine diet.
Dayre McNally, J; Matheson, Loren A; Sankaran, Koravangattu; Rosenberg, Alan M
2008-11-01
This study compared 25-hydroxyvitamin D [25(OH)D] measurements in capillary and venous blood samples collected, respectively by fingerprick and venipuncture. Capillary blood for measuring 25(OH)D has potential advantages by reducing blood volume required (2mL versus 0.3mL for venipuncture and capillary sampling, respectively), facilitating blood collection for those populations in whom venipuncture is difficult (e.g. infants and children), improving patient convenience and reducing costs associated with phlebotomy. The results demonstrated a highly significant relationship between 25(OH)D levels in serum derived from venous and capillary blood samples (r(2)=0.901). Despite statistically higher 25(OH)D levels in fingerprick samples (108+/-9nmol/L) compared with venipuncture samples (90+/-7nmol/L), the correlation between venous and capillary samples provides support for this approach as a practical alternative to venipuncture for vitamin D determination. However, clinical application may require the incorporation of a correction factor for the assessment of insufficiency, and research studies should avoid using the two methods interchangeably. Studying vitamin D's role in health and disease requires collection techniques and measurement methods that are reliable, reproducible, easily accessible, inexpensive and minimally burdensome to the patient. The option to collect patient samples by fingerprick may facilitate the collection process.
Nirogi, Ramakrishna; Ajjala, Devender Reddy; Kandikere, Vishwottam; Aleti, Raghupathi; Srikakolapu, SuryaRao; Vurimindi, Himabindu
2012-10-15
Deferasirox is an iron chelating agent for the treatment of transfusional iron over load in patients with chronic anemia. These anemic patients require close monitoring of the deferasirox exposures for ensuring its therapeutic efficacy. Dried blood spot (DBS) sampling methodology has the advantages of low volume of blood withdrawal and ease of transportation and storage over liquid blood methods. A LC-MS/MS based analytical method was developed using reversed phase column with gradient elution program and quantitated in MRM mode. Linearity range for the liquid blood was 1-1000 ng/mL and for DBS was 5-5000 ng/mL under similar mass spectrometry conditions. The method was validated with respective (M-H)(-) ions, m/z 372→118 for deferasirox and m/z 410→348 for fluvastatin (internal standard). The validated method was applied for the analysis of DBS samples from a rat pharmacokinetic study and results were compared against liquid blood samples from the same animal. The mean C(max) from DBS sample (1121 ng/mL) was comparable to mean C(max) found in blood samples (1015 ng/mL) at 2h after oral dose of deferasirox. All the other calculated pharmacokinetic parameters were quite comparable for both liquid blood and DBS samples. Copyright © 2012. Published by Elsevier B.V.
van der Ster, Björn J P; Bennis, Frank C; Delhaas, Tammo; Westerhof, Berend E; Stok, Wim J; van Lieshout, Johannes J
2017-01-01
Introduction: In the initial phase of hypovolemic shock, mean blood pressure (BP) is maintained by sympathetically mediated vasoconstriction rendering BP monitoring insensitive to detect blood loss early. Late detection can result in reduced tissue oxygenation and eventually cellular death. We hypothesized that a machine learning algorithm that interprets currently used and new hemodynamic parameters could facilitate in the detection of impending hypovolemic shock. Method: In 42 (27 female) young [mean (sd): 24 (4) years], healthy subjects central blood volume (CBV) was progressively reduced by application of -50 mmHg lower body negative pressure until the onset of pre-syncope. A support vector machine was trained to classify samples into normovolemia (class 0), initial phase of CBV reduction (class 1) or advanced CBV reduction (class 2). Nine models making use of different features were computed to compare sensitivity and specificity of different non-invasive hemodynamic derived signals. Model features included : volumetric hemodynamic parameters (stroke volume and cardiac output), BP curve dynamics, near-infrared spectroscopy determined cortical brain oxygenation, end-tidal carbon dioxide pressure, thoracic bio-impedance, and middle cerebral artery transcranial Doppler (TCD) blood flow velocity. Model performance was tested by quantifying the predictions with three methods : sensitivity and specificity, absolute error, and quantification of the log odds ratio of class 2 vs. class 0 probability estimates. Results: The combination with maximal sensitivity and specificity for classes 1 and 2 was found for the model comprising volumetric features (class 1: 0.73-0.98 and class 2: 0.56-0.96). Overall lowest model error was found for the models comprising TCD curve hemodynamics. Using probability estimates the best combination of sensitivity for class 1 (0.67) and specificity (0.87) was found for the model that contained the TCD cerebral blood flow velocity derived pulse height. The highest combination for class 2 was found for the model with the volumetric features (0.72 and 0.91). Conclusion: The most sensitive models for the detection of advanced CBV reduction comprised data that describe features from volumetric parameters and from cerebral blood flow velocity hemodynamics. In a validated model of hemorrhage in humans these parameters provide the best indication of the progression of central hypovolemia.
Prognostic significance of blood lactate and lactate clearance in trauma patients.
Régnier, Marie-Alix; Raux, Mathieu; Le Manach, Yannick; Asencio, Yves; Gaillard, Johann; Devilliers, Catherine; Langeron, Olivier; Riou, Bruno
2012-12-01
Lactate has been shown to be a prognostic biomarker in trauma. Although lactate clearance has already been proposed as an intermediate endpoint in randomized trials, its precise role in trauma patients remains to be determined. Blood lactate levels and lactate clearance (LC) were calculated at admission and 2 and 4 h later in trauma patients. The association of initial blood lactate level and lactate clearance with mortality was tested using receiver-operating characteristics curve, logistic regression using triage scores, Trauma Related Injury Severity Score as a reference standard, and reclassification method. The authors evaluated 586 trauma patients (mean age 38±16 yr, 84% blunt and 16% penetrating, mortality 13%). Blood lactate levels at admission were elevated in 327 (56%) patients. The lactate clearance should be calculated within the first 2 h after admission as LC0-2 h was correlated with LC0-4 h (R=0.55, P<0.001) but not with LC2-4 h (R=0.04, not significant). The lactate clearance provides additional predictive information to initial blood lactate levels and triage scores and the reference score. This additional information may be summarized using a categorical approach (i.e., less than or equal to -20 %/h) in contrast to initial blood lactate. The results were comparable in patients with high (5 mM/l or more) initial blood lactate. Early (0-2 h) lactate clearance is an important and independent prognostic variable that should probably be incorporated in future decision schemes for the resuscitation of trauma patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bruner, A.
1976-09-01
Four groups of monkeys received 1000 rads (60)Co at 33, 50, 75, or 180 rad/min wholebody irradiation while performing a delayed matching-to-sample task. Systematic dose rate effects were observed on performance and blood pressure within the initial 20 min postirradiation. The incidence and severity of performance decrement (PD) increased with higher dose rate. The appearance of postirradiation hypotension was systematically delayed and its rate of fall prolonged as dose rate was lower. The hypotension likewise appeared less deep with lower dose rate exposure. Based on the calculated cumulative dose absorbed at the time of symptom appearance two coactive thresholds weremore » proposed to exist: a total dose threshold of approximately 300 rads (midbody measurement), and a dose rate threshold of about 25 rad/min.« less
Fast differentiation of SIRS and sepsis from blood plasma of ICU patients using Raman spectroscopy.
Neugebauer, Ute; Trenkmann, Sabine; Bocklitz, Thomas; Schmerler, Diana; Kiehntopf, Michael; Popp, Jürgen
2014-04-01
Currently, there is no biomarker that can reliable distinguish between infectious and non-infectious systemic inflammatory response syndrome (SIRS). However, such a biomarker would be of utmost importance for early identification and stratification of patients at risk to initiate timely and appropriate antibiotic treatment. Within this proof of principle study, the high potential of Raman spectroscopy for the fast differentiation of non-infectious SIRS and sepsis is demonstrated. Blood plasma collected from 70 patients from the intensive care unit (31 patients with sepsis and 39 patients classified with SIRS without infection) was analyzed by means of Raman spectroscopy. A PCA-LDA based classification model was trained with Raman spectra from test samples and yielded for sepsis a sensitivity of 1.0 and specificity of 0.82. These results have been confirmed with an independent dataset (prediction accuracy 80%). Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Self-paced exercise program for office workers: impact on productivity and health outcomes.
Low, David; Gramlich, Martha; Engram, Barbara Wright
2007-03-01
The impact of a self-paced exercise program on productivity and health outcomes of 32 adult workers in a large federal office complex was investigated during 3 months. Walking was the sole form of exercise. The first month, during which no walking occurred, was the control period. The second and third months were the experimental period. Participants were divided into three levels based on initial weight and self-determined walking distance goals. Productivity (using the Endicott Work Productivity Scale), walking distance (using a pedometer), and health outcomes (blood pressure, weight, pulse rate, and body fat percentage) were measured weekly. Results from this study, based on a paired t test analysis, suggest that although the self-paced exercise program had no impact on productivity, it lowered blood pressure and promoted weight loss. Further study using a larger sample and a controlled experimental design is recommended to provide conclusive evidence.
Webster, Glenys M; Teschke, Kay; Janssen, Patricia A
2012-02-01
To describe and evaluate recruitment techniques used to enroll 152 healthy pregnant women fewer than 15 weeks gestation into a prospective study of environmental chemical exposure during pregnancy. Posters, a website, online and print advertising, recruitment emails, media coverage, recruitment from clinic waiting rooms, networking within the pregnancy community and presenting a study booth at baby "trade shows" were used to advertise the study. Participants had to meet a strict set of eligibility criteria, and were asked to donate two-second-trimester blood samples, complete two questionnaires, have samples of air, dust, lint and tap water collected from their homes, and donate a cord blood sample at delivery. Over 17 months, 171 women enrolled (49% of initial contacts, and 99% of all eligible women) and 152 women completed the study (89% retention). Total recruitment costs were approximately $400 Cdn per final participant. Posters, study booth presentations and online advertising generated the most inquiries about the study. Word of mouth, referral from another study and direct email were the most cost-effective strategies. Not surprisingly, the recruited study population was less ethnically diverse, more affluent and more educated than the background population of pregnant women in Vancouver. A combination of passive and active recruitment techniques were successful for recruiting healthy women in roughly the first trimester of pregnancy (<15 weeks gestation). While a convenience sample of women is suitable for our study questions, additional strategies may be required to recruit a more representative pregnant population in future studies.
Simplified Pan-species Real-time PCR-based Detection of Plasmodium Spp. in Blood Smear
HASSANPOUR, Gholamreza; MIRHENDI, Hossein; MOHEBALI, Mehdi; RAEISI, Ahmad; ZERAATI, Hojjat; KESHAVARZ, Hossein
2016-01-01
Background: We aimed to quicken and simplify the detection of Plasmodium in blood samples by developing and testing a pan-Plasmodium real-time PCR for accurate screening of individuals suspected of malaria. Methods: A single primer/probe set for pan-species Plasmodium-specific real time PCR targeting a conserved region of the small subunit 18S ribosomal DNA was designed and evaluated for rapid diagnosis and screening of malaria infections using dried blood smears. FTA cards were used for rapid and simple DNA extraction. Results: The primers and probes showed a positive response with the DNA extracted from bloods infected with P. falciparum and P. vivax but not with DNA extracted from various smears from uninfected blood samples. Seven positive cases positive by both microscopy and nested PCR were found among 280 blood samples taken from in South and Southeast Iran. Five samples were identified as positive for P. vivax and two as positive for P. falciparum. All positive samples were positive by real-time PCR. Furthermore, all 38-blood samples positive by microscopy were positive by real-time PCR. No microscopy-negative samples were positive by real-time PCR. Conclusion: By using a simple FTA card for DNA extraction and by application of the real-time PCR developed in this study, sensitivity similar to nested-PCR and microscopy was achieved. This format simplifies the detection of Plasmodium in large numbers of samples. PMID:28127357
Zakaria, Rosita; Allen, Katrina J.; Koplin, Jennifer J.; Roche, Peter
2016-01-01
Introduction Through the introduction of advanced analytical techniques and improved throughput, the scope of dried blood spot testing utilising mass spectrometric methods, has broadly expanded. Clinicians and researchers have become very enthusiastic about the potential applications of dried blood spot based mass spectrometric applications. Analysts on the other hand face challenges of sensitivity, reproducibility and overall accuracy of dried blood spot quantification. In this review, we aim to bring together these two facets to discuss the advantages and current challenges of non-newborn screening applications of dried blood spot quantification by mass spectrometry. Methods To address these aims we performed a key word search of the PubMed and MEDLINE online databases in conjunction with individual manual searches to gather information. Keywords for the initial search included; “blood spot” and “mass spectrometry”; while excluding “newborn”; and “neonate”. In addition, databases were restricted to English language and human specific. There was no time period limit applied. Results As a result of these selection criteria, 194 references were identified for review. For presentation, this information is divided into: 1) clinical applications; and 2) analytical considerations across the total testing process; being pre-analytical, analytical and post-analytical considerations. Conclusions DBS analysis using MS applications is now broadly applied, with drug monitoring for both therapeutic and toxicological analysis being the most extensively reported. Several parameters can affect the accuracy of DBS measurement and further bridge experiments are required to develop adjustment rules for comparability between dried blood spot measures and the equivalent serum/plasma values. Likewise, the establishment of independent reference intervals for dried blood spot sample matrix is required. PMID:28149263
Blood Warming and Hemolysis: A Systematic Review With Meta-Analysis.
Poder, Thomas G; Nonkani, Wendyam G; Tsakeu Leponkouo, Élyonore
2015-07-01
The use of fluid warmers during blood transfusion is recommended to avoid inducing hypothermia and its harmful effects. Fluid warmers offered by manufacturers can reach temperatures of 43°C. However, the recommendations of national regulatory organizations do not clearly indicate the maximum heating temperature in relation to the risk of hemolysis. To fill this gap, we conducted a systematic review of the literature with meta-analysis. To match clinical practice, this review was limited to fluid warmers that used contact heating; thus, studies that used radiofrequency or microwave heating were excluded. Twenty-four observational studies were included, 17 of which were the subject of a meta-analysis. A preliminary descriptive analysis indicated that multiple factors can influence the level of hemolysis during blood heating with a liquid warmer, including blood age, anticoagulant type, duration of exposure to heat, stirring the blood during heating, and various elements of the circuit through which blood flows (eg, type of infusion pump with pressure and flow, type of microfilter, and type of tubing). Moreover, the duration between sampling and hemolysis assay was a source of heterogeneity among studies, as were the initial free hemoglobin levels in the various experiments. In general, the increase generated by each of these factors other than temperature appears to have been limited except for blood age, which is an important parameter of hemolysis, the length of exposure to heat, and, in some studies, the type of infusion pump used. Regarding the meta-analysis, at temperatures at or less than 43°C and even up to 45-46°C, it appears that blood heating is safe and causes hemolysis only in clinically negligible proportions. Copyright © 2015 Elsevier Inc. All rights reserved.
Closing the Loop on Critical Care Life Support for Military en route Care Environments
2004-09-01
pig’s blood volume. Resuscitation was then initiated by turning on the autocontrol software which ran on an external computer which was receiving mean...that initiated the occlusion alarm. When the occlusion was released, the autocontrol resumed automatically and restored the blood pressure once again
Multiplex method for initial complex testing of antibodies to blood transmitted diseases agents.
Poltavchenko, Alexander G; Nechitaylo, Oleg V; Filatov, Pavel V; Ersh, Anna V; Gureyev, Vadim N
2016-10-01
Initial screening of donors and population at high risk of infection with blood transmitted diseases involves a number of analyses using monospesific diagnostic systems, and therefore is expensive labor- and time-consuming process. The goal of this work is to construct a multiplex test enabling to carry out rapid initial complex testing at a low price. The paper describes a kit making it possible to detect simultaneously antibodies to six agents of the most significant blood transmitted diseases: HIV virus, hepatitis B and C viruses, cytomegalovirus, T. pallidum and T. gondii in blood products. The kit comprises multiplex dot-immunoassay based on plane protein arrays (immune chips) using colloidal gold conjugates and silver development. It provides an opportunity to carry out complex analysis within 70min at room temperature, and there is no need of well-qualified personnel. We compared laboratory findings of the kit with monospecific kits for ELISA produced by two Russian commercial companies. Dot-assay results correlate well with data obtained using commercial kits for ELISA. Furthermore, multiplex analysis is quicker and cheaper in comparison with ELISA and can be carried out in non-laboratory conditions. The kit for multiplex dot-immunoassay of antibodies to blood transmitted agents can significantly simplify initial complex testing. Copyright © 2016 Elsevier B.V. All rights reserved.
Takei, Yoshio; Suzuki, Ippei; Wong, Marty K S; Milne, Ryan; Moss, Simon; Sato, Katsufumi; Hall, Ailsa
2016-10-01
An animal-borne blood sampler with data-logging functions was developed for phocid seals, which collected two blood samples for the comparison of endocrinological/biochemical parameters under two different conditions. The sampler can be triggered by preset hydrostatic pressure, acceleration (descending or ascending), temperature, and time, and also manually by light. The sampling was reliable with 39/50 (78%) successful attempts to collect blood samples. Contamination of fluids in the tubing to the next blood sample was <1%, following the prior clearance of the tubing to a waste syringe. In captive harbor seals ( Phoca vitulina ), the automated blood-sampling method was less stressful than direct blood withdrawal, as evidenced by lower levels of stress hormones ( P < 0.05 for ACTH and P = 0.078 for cortisol). HPLC analyses showed that both cortisol and cortisone were circulating in seal blood. Using the sampler, plasma levels of cardiovascular hormones, atrial natriuretic peptide (ANP), AVP, and ANG II were compared in grey seals ( Halichoerus grypus ), between samples collected when the animals were on land and in the water. HPLC analyses determined that [Met 12 ] ANP (1-28) and various forms of angiotensins (ANG II, III, and IV) were circulating in seal blood. Although water immersion profoundly changes the plasma levels of cardiovascular hormones in terrestrial mammals, there were only tendencies toward an increase in ANP ( P = 0.069) and a decrease in AVP ( P = 0.074) in the seals. These results suggest that cardiovascular regulation in phocid seals may have undergone adaptation during evolution of the carnivore to a semiaquatic lifestyle. Copyright © 2016 the American Physiological Society.
Bloch, Evan M; Marshall, Christi E; Boyd, Joan S; Shifflett, Lisa; Tobian, Aaron A R; Gehrie, Eric A; Ness, Paul M
2018-04-01
Bacterial contamination of platelets remains a major transfusion-associated risk despite long-standing safety measures in the United States. We evaluated an approach using secondary bacterial culture (SBC) to contend with residual risk of bacterial contamination. Phased implementation of SBC was initiated in October 2016 for platelets (all apheresis collected) received at our institution from the blood donor center (Day 3 post collection). Platelet products were sampled aseptically (5 mL inoculated into an aerobic bottle [BacT/ALERT BPA, BioMerieux, Inc.]) by the blood bank staff upon receipt, using a sterile connection device and sampling kit. The platelet sample was inoculated into an aerobic blood culture bottle and incubated at 35°C for 3 days. The cost of SBC was calculated on the basis of consumables and labor costs at time of implementation. In the 13 months following implementation (October 6, 2016, to November 30, 2017), 23,044/24,653 (93.47%) platelet products underwent SBC. A total of eight positive cultures were detected (incidence 1 in 2881 platelet products), seven of which were positive within 24 hours of SBC. Coagulase negative Staphyloccus spp. were identified in four cases. Five of the eight cases were probable true positive (repeat reactive) and interdicted (cost per averted case was US$77,935). The remaining three cases were indeterminate. No septic transfusion reactions were reported during the observation period. We demonstrate the feasibility of SBC of apheresis platelets to mitigate bacterial risk. SBC is lower cost than alternative measures (e.g., pathogen reduction and point-of-release testing) and can be integrated into workflow at hospital transfusion services. © 2018 AABB.
Silk-based blood stabilization for diagnostics.
Kluge, Jonathan A; Li, Adrian B; Kahn, Brooke T; Michaud, Dominique S; Omenetto, Fiorenzo G; Kaplan, David L
2016-05-24
Advanced personalized medical diagnostics depend on the availability of high-quality biological samples. These are typically biofluids, such as blood, saliva, or urine; and their collection and storage is critical to obtain reliable results. Without proper temperature regulation, protein biomarkers in particular can degrade rapidly in blood samples, an effect that ultimately compromises the quality and reliability of laboratory tests. Here, we present the use of silk fibroin as a solid matrix to encapsulate blood analytes, protecting them from thermally induced damage that could be encountered during nonrefrigerated transportation or freeze-thaw cycles. Blood samples are recovered by simple dissolution of the silk matrix in water. This process is demonstrated to be compatible with a number of immunoassays and provides enhanced sample preservation in comparison with traditional air-drying paper approaches. Additional processing can remediate interactions with conformational structures of the silk protein to further enhance blood stabilization and recovery. This approach can provide expanded utility for remote collection of blood and other biospecimens empowering new modalities of temperature-independent remote diagnostics.
Nelson, Kristin N; Hui, Qin; Rimland, David; Xu, Ke; Freiberg, Matthew S; Justice, Amy C; Marconi, Vincent C; Sun, Yan V
2017-02-20
HIV-positive individuals are at higher risk than healthy persons for aging-related diseases, including myocardial infarction and non-AIDS defining cancers. Recent evidence suggests that HIV infection may modulate changes in the host cell epigenome, and these changes represent a potential mechanism through which HIV infection accelerates aging. We assessed the difference in DNA methylation (DNAm) age, an aging marker involving multiple age-related cytosine-guanine dinucleotide (CpG) sites, among antiretroviral treatment (ART)-naive HIV-positive and HIV-negative individuals in a cohort of veterans from the Veterans Aging Cohort Study. Peripheral blood samples were collected from 19 ART-naive, HIV-positive, and 19 HIV-negative male participants, matched by age and race. Blood samples were collected from HIV-positive participants 7-11 years after ART initiation. We compared DNAm age between HIV-positive and HIV-negative groups at baseline and between HIV-positive patients at baseline and follow-up. We also performed an epigenome-wide analysis to identify CpG methylation sites associated with HIV infection. DNAm age in HIV-positive individuals is, on average, 11.2 years higher than HIV study participants at baseline, and two of 10 HIV-positive individuals showed an increase in DNAm age after ART initiation. Epigenome-wide association studies showed an association of HIV infection with one site, in gene VPS37B, which approached statistical significance in our cohort (P = 3.30 × 10, Bonferroni-corrected threshold = 1.22 × 10) and was replicated in a second, larger cohort. ART treatment-naive HIV-positive individuals have significantly older DNAm age compared to HIV-negative individuals in the Veterans Aging Cohort Study cohort. Longitudinal changes in DNAm age are highly variable across individuals after initiation of antiretroviral therapy.
Biobanking in a Challenging African Environment: Unique Experience from the SIREN Project.
Akinyemi, Rufus O; Akinwande, Kazeem; Diala, Samuel; Adeleye, Osi; Ajose, Abiodun; Issa, Kehinde; Owusu, Dorcas; Boamah, Isaac; Yahaya, Isah Suleiman; Jimoh, Abdulraheem Olayemi; Imoh, Lucius; Fakunle, Gregory; Akpalu, Albert; Sarfo, Fred; Wahab, Kolawole; Sanya, Emmanuel; Owolabi, Lukman; Obiako, Reginald; Osaigbovo, Godwin; Komolafe, Morenikeji; Fawale, Michael; Adebayo, Philip; Olowoyo, Paul; Obiabo, Yahaya; Sunmonu, Taofiki; Chukwuonye, Ijezie; Balogun, Olayemi; Adeoye, Basirat; Oladele, Florence; Olowoniyi, Peter; Adeyemi, Frederick; Lezzi, Arthur; Falayi, Ajibola Tunde; Fasanya, Michael; Ogunwale, Kolawole; Adeola, Olabisi; Olomu, Omolara; Aridegbe, Olumayowa; Laryea, Ruth; Uvere, Ezinne; Faniyan, Moyinoluwalogo; Melikam, Ezinne; Tagge, Raelle; Akpa, Onoja; Akinyemi, Joshua; Arulogun, Oyedunni; Tiwari, Hemant K; Ovbiagele, Bruce; Owolabi, Mayowa
2018-05-07
Africa was previously insufficiently represented in the emerging discipline of biobanking despite commendable early efforts. However, with the Human, Heredity, and Health in Africa (H3Africa) initiative, biorepository science has been bolstered, regional biobanks are springing up, and awareness about biobanks is growing on the continent. The Stroke Investigative Research and Educational Network (SIREN) project is a transnational, multicenter, hospital and community-based study involving over 3000 cases and 3000 controls recruited from 16 sites in Ghana and Nigeria. SIREN aims to explore and unravel the genetic and environmental factors that interact to produce the peculiar phenotypic and clinical characteristics of stroke as seen in people of African ancestry and facilitate the development of new diagnostics, therapeutics, and preventative strategies. The aim of this article is to describe our experience with the development of the procedure for collection, processing, storage, and shipment of biological samples (blood, serum, plasma, buffy coat, red cell concentrates, and DNA) and brain imaging across coordinating and participating sites within the SIREN Project. The SIREN network was initiated in 2014 with support and funding from the H3Africa Initiative. The SIREN Biobank currently has 3015 brain images, 92,950 blood fractions (serum, plasma, red cell concentrates, and buffy coat) accrued from 8450 recruited subjects, and quantified and aliquoted good-quality DNA extracts from 6150 study subjects. This represents an invaluable resource for future research with expanding genomic and trans-omic technologies. This will facilitate the involvement of indigenous African samples in cutting-edge stroke genomics and trans-omics research. It is, however, critical to effectively engage African stroke patients and community members who have contributed precious biological materials to the SIREN Biobank to generate appropriate evidence base for dealing with ethical, legal, and social issues of privacy, autonomy, identifiability, biorights, governance issues, and public understanding of stroke biobanking in the context of unique African culture, language, and belief systems.
Cost-effective and Rapid Blood Analysis on a Cell-phone
Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan
2013-01-01
We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings. PMID:23392286
Cost-effective and rapid blood analysis on a cell-phone.
Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan
2013-04-07
We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings.
A simple technic for repeated collection of blood samples from mice.
Stoltz, D R; Bendall, R D
1975-06-01
A device for repeated collection of small blood samples from mice was constructed from a plastic syringe. Blood was collected into a 3.33 lambda capillary tube. Bleeding was stopped by a hemostat made from a rubber stopper. This technic allows easy collection of approximately 20 serial samples within an 8-hr period.
Sampling methods to the statistical control of the production of blood components.
Pereira, Paulo; Seghatchian, Jerard; Caldeira, Beatriz; Santos, Paula; Castro, Rosa; Fernandes, Teresa; Xavier, Sandra; de Sousa, Gracinda; de Almeida E Sousa, João Paulo
2017-12-01
The control of blood components specifications is a requirement generalized in Europe by the European Commission Directives and in the US by the AABB standards. The use of a statistical process control methodology is recommended in the related literature, including the EDQM guideline. The control reliability is dependent of the sampling. However, a correct sampling methodology seems not to be systematically applied. Commonly, the sampling is intended to comply uniquely with the 1% specification to the produced blood components. Nevertheless, on a purely statistical viewpoint, this model could be argued not to be related to a consistent sampling technique. This could be a severe limitation to detect abnormal patterns and to assure that the production has a non-significant probability of producing nonconforming components. This article discusses what is happening in blood establishments. Three statistical methodologies are proposed: simple random sampling, sampling based on the proportion of a finite population, and sampling based on the inspection level. The empirical results demonstrate that these models are practicable in blood establishments contributing to the robustness of sampling and related statistical process control decisions for the purpose they are suggested for. Copyright © 2017 Elsevier Ltd. All rights reserved.
Fischer, I; Christen, C; Lutz, H; Gerlach, H; Hässig, M; Hatt, J-M
2006-10-07
Two groups of 22 budgerigars (Melopsittacus undulatus) were housed for 12 months under identical conditions. One group was fed a commercial seed mixture plus carrots and a mineral supplement, and the other group was fed a commercially formulated diet plus carrots. Samples of blood and faeces were collected initially and after three, six, nine and 12 months. There were no significant differences between the haematological values of the two groups. The group fed the seed mixture had significantly higher concentrations of glucose, albumin, triglycerides and uric acid, and higher activity of aspartate aminotransferase, but the values were within the published reference ranges for normal birds. There were no significant differences between the faecal samples from the two groups, except that the fungus Macrorhabdus ornithogaster was identified in 48.3 per cent of the samples from the group fed the commercially formulated diet but from only 3.4 per cent of the samples from the group fed the seed mixture.
Hassanpour, Gholamreza; Mohebali, Mehdi; Raeisi, Ahmad; Abolghasemi, Hassan; Zeraati, Hojjat; Alipour, Mohsen; Azizi, Ebrahim; Keshavarz, Hossein
2011-06-01
The transmission of malaria by blood transfusion was one of the first transfusion-transmitted infections recorded in the world. Transfusion-transmitted malaria may lead to serious problems because infection with Plasmodium falciparum may cause rapidly fatal death. This study aimed to compare real-time polymerase chain reaction (real-time PCR) with rapid diagnostic test (RDT) and light microscopy for the detection of Plasmodium spp. in blood transfusion, both in endemic and non-endemic areas of malaria disease in Iran. Two sets of 50 blood samples were randomly collected. One set was taken from blood samples donated in blood bank of Bandar Abbas, a city located in a malarious-endemic area, and the other set from Tehran, a non-endemic one. Light microscopic examination on both thin and thick smears, RDTs, and real-time PCR were performed on the blood samples and the results were compared. Thin and thick light microscopic examinations of all samples as well as RDT results were negative for Plasmodium spp. Two blood samples from endemic area were positive only with real-time PCR. It seems that real-time PCR as a highly sensitive method can be helpful for the confirmation of malaria infection in different units of blood transfusion organization especially in malaria-endemic areas where the majority of donors may be potentially infected with malaria parasites.
Reduction in Blood Culture Contamination Through Use of Initial Specimen Diversion Device.
Rupp, Mark E; Cavalieri, R Jennifer; Marolf, Cole; Lyden, Elizabeth
2017-07-15
Blood culture contamination is a clinically significant problem that results in patient harm and excess cost. In a prospective, controlled trial at an academic center Emergency Department, a device that diverts and sequesters the initial 1.5-2 mL portion of blood (which presumably carries contaminating skin cells and microbes) was tested against standard phlebotomy procedures in patients requiring blood cultures due to clinical suspicion of serious infection. In sum, 971 subjects granted informed consent and were enrolled resulting in 904 nonduplicative subjects with 1808 blood cultures. Blood culture contamination was significantly reduced through use of the initial specimen diversion device™ (ISDD) compared to standard procedure: (2/904 [0.22%] ISDD vs 16/904 [1.78%] standard practice, P = .001). Sensitivity was not compromised: true bacteremia was noted in 65/904 (7.2%) ISDD vs 69/904 (7.6%) standard procedure, P = .41. No needlestick injuries or potential bloodborne pathogen exposures were reported. The monthly rate of blood culture contamination for all nurse-drawn and phlebotomist-drawn blood cultures was modeled using Poisson regression to compare the 12-month intervention period to the 6 month before and after periods. Phlebotomists (used the ISDD) experienced a significant decrease in blood culture contamination while the nurses (did not use the ISDD) did not. In sum, 73% of phlebotomists completed a post-study anonymous survey and widespread user satisfaction was noted. Use of the ISDD was associated with a significant decrease in blood culture contamination in patients undergoing blood cultures in an Emergency Department setting. NCT02102087. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.
NASA Astrophysics Data System (ADS)
Ekawati, ER; Yusmiati, S. N. H.
2018-01-01
Blood cockle (Anadara granosa) has high level of zinc and protein, which is beneficial for therapeutic function for malnourished particularly stunting case in children. Zinc in animal foods is more absorbable than that from vegetable food. Blood cockle (Anadara granosa) is rich in nutrient and an excellent environment for the growth of microorganisms. This research aimed to identify the contamination of Salmonella sp., Vibrio sp. and total plate count bacteria on blood cockle (Anadara granosa). This was observation research with laboratory analysis. Salmonella sp. and Vibrio sp. were detected from blood cockle. Total plate count was determine of the total amount of the bacteria. Results detected from 20 samples of blood cockle showed that all samples were negative of Salmonella sp. and 1 sample positive Vibrio sp. The result of total plate count bacteria was < 5 x 105 colony/g sample.
Colucci, G; Giabbani, E; Barizzi, G; Urwyler, N; Alberio, L
2011-08-01
ROTEM(®) is considered a helpful point-of-care device to monitor blood coagulation. Centrally performed analysis is desirable but rapid transport of blood samples and real-time transmission of graphic results are an important prerequisite. The effect of sample transport through a pneumatic tube system on ROTEM(®) results is unknown. The aims of the present work were (i) to determine the influence of blood sample transport through a pneumatic tube system on ROTEM(®) parameters compared to manual transportation, and (ii) to verify whether graphic results can be transmitted on line via virtual network computing using local area network to the physician in charge of the patient. Single centre study with 30 normal volunteers. Two whole blood samples were transferred to the central haematology laboratory by either normal transport or pneumatic delivery. EXTEM, INTEM, FIBTEM and APTEM were analysed in parallel with two ROTEM(®) devices and compared. Connection between central laboratory, emergency and operating rooms was established using local area network. All collected ROTEM(®) parameters were within normal limits. No statistically significant differences between normal transport and pneumatic delivery were observed. Real-time transmission of the original ROTEM(®) curves using local area network is feasible and easy to establish. At our institution, transport of blood samples by pneumatic delivery does not influence ROTEM(®) parameters. Blood samples can be analysed centrally, and results transmitted live via virtual network computing to emergency or operating rooms. Prior to analyse blood samples centrally, the type of sample transport should be tested to exclude in vitro blood activation by local pneumatic transport system. © 2011 Blackwell Publishing Ltd.
A content validated questionnaire for assessment of self reported venous blood sampling practices
2012-01-01
Background Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. Findings We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. Conclusions The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward. PMID:22260505
A content validated questionnaire for assessment of self reported venous blood sampling practices.
Bölenius, Karin; Brulin, Christine; Grankvist, Kjell; Lindkvist, Marie; Söderberg, Johan
2012-01-19
Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward.
Depleted uranium analysis in blood by inductively coupled plasma mass spectrometry
Todorov, T.I.; Xu, H.; Ejnik, J.W.; Mullick, F.G.; Squibb, K.; McDiarmid, M.A.; Centeno, J.A.
2009-01-01
In this study we report depleted uranium (DU) analysis in whole blood samples. Internal exposure to DU causes increased uranium levels as well as change in the uranium isotopic composition in blood specimen. For identification of DU exposure we used the 235U/238U ratio in blood samples, which ranges from 0.00725 for natural uranium to 0.002 for depleted uranium. Uranium quantification and isotopic composition analysis were performed by inductively coupled plasma mass spectrometry. For method validation we used eight spiked blood samples with known uranium concentrations and isotopic composition. The detection limit for quantification was determined to be 4 ng L-1 uranium in whole blood. The data reproduced within 1-5% RSD and an accuracy of 1-4%. In order to achieve a 235U/238U ratio range of 0.00698-0.00752% with 99.7% confidence limit a minimum whole blood uranium concentration of 60 ng L??1 was required. An additional 10 samples from a cohort of veterans exposed to DU in Gulf War I were analyzed with no knowledge of their medical history. The measured 235U/ 238U ratios in the blood samples were used to identify the presence or absence of DU exposure within this patient group. ?? 2009 The Royal Society of Chemistry.
The effect of storage on whole blood chemiluminescence measurement of equine neutrophils.
Krumrych, Wiesław; Skórzewski, Radosław; Malinowski, Edward
2013-01-01
The aim of this study was to determine the effect of duration and temperature of sample storage on whole blood chemiluminescence measurement results. Venous blood from 18 clinically healthy Polish half-bred horses aged 4 to 11 years were used in the study. Luminol dependent chemiluminescence (CL) was used to measure neutrophil oxygen metabolism in whole blood. Blood samples were examined for spontaneous CL and stimulated by a surface receptor stimulus as well as extra-receptor stimulus. The assay was performed in two parallel experimental sets with samples stored at 4 and 22 °C, respectively. Whole blood CL was estimated at 2, 6, 24, 48, 72, 96 and 120 h after collection. The study demonstrated that temperature and duration of sample storage are factors that determine the quality of CL measurements of whole blood in horses. The study concluded that samples should be stored at 4 °C and the assay should be performed as early as possible. It was also shown that the viability period of horse blood for CL assays is relatively long. Material stored at room temperature for 24 h and even up to 48 h at 4 °C did not show any significant decrease in spontaneous or stimulated chemiluminescence. Copyright © 2012 John Wiley & Sons, Ltd.
Evaluating Oral Fluid as a Screening Tool for Lead Poisoning.
Gardner, Sher Lynn; Geller, Robert J; Hannigan, Robyn; Sun, Yu; Mangla, Anil
2016-11-01
Screening for lead poisoning is necessary in young children, but obtaining the needed blood sample is unpleasant and sometimes very difficult. Use of an alternative screening method that is less unpleasant and less difficult would likely help to increase the percent of children receiving screening. To evaluate the correlation of oral fluid and blood lead in a clinical setting, and to ascertain the acceptability and feasibility of obtaining oral fluid from a young child in the clinical setting. Oral fluid samples were collected from a convenience sample of 431 children aged 6 months to 5 years already due to receive a blood lead test in a primary care clinic. Blood lead results obtained at the same time were available for 407 children. The results of the two tests were compared with the blood lead test considered to be the "gold standard". Data analysis used Pearson correlations, scatter plots, linear regression, ANOVA and Bland-Altman analysis. 431 patients had oral fluid samples available for analysis, and 407 patients had blood samples available. Patients who had both blood concentrations <5 µg/dL and oral fluid values below the screening cutoff value were 223, while eight had both blood concentrations ≥ 5 µg/dL and oral fluid values above the screening threshold. Elevated oral fluid but blood lead values less than the value recommended for further intervention occurred in 176; no patients had elevated blood lead values with below-intervention oral fluid values. The negative predictive value of an oral fluid lead below the screening cutoff value was 100%. The use of oral fluid to screen for elevated body burdens of lead instead of the usual blood lead sample is feasible with a negative predictive value of 100%, while eliminating the need for blood for lead screening in more than half of these children. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Dong, Xiao-lian; Yao, Qing-qing; Wang, Xue-cai; Xu, Hai-tao; Wang, Xiao-li; Chen, Sheng-yu; Tang, Zhi-feng; Zheng, Ying-Jie
2013-03-01
Prevalence of occult hepatitis B virus (HBV) infection (OBI) was investigated in a paired mother-teenager population and HBV S gene variation including overt and occult HBV, was determined. A follow-up study based on an initial survey of 135 mother-teenager pairs was carried out through collection of questionnaires and blood samples HBsAg were detected by ELISA method, viral load by PCR amplification and HBV S gene by phylogenetic analysis. 102 pairs of subjects were followed-up. Blood samples from 94 mothers and 101 children were collected. OBI prevalence in mothers was 10.0% (6/60), significantly higher than 2.0% (2/101) in teenagers. Medians of viral load were 399.9 IU/ml and 247.6 IU/ml in overt and occult HBV strains, but without significant difference. 1 occult HBV strain belonged to genotype B with serotype adw while the other 7 were genotype C with serotype adr. 15 of the overt HBV strains belonged to genotype B with serotype adw and the other 8 were genotype C with serotype adr. Proportions of genotype-C strains were significantly higher in occult HBV strains than in overt HBV strains. OBI was seen in teenage-mother population.
Adrenal Vein Sampling for Conn's Syndrome: Diagnosis and Clinical Outcomes.
Deipolyi, Amy R; Bailin, Alexander; Wicky, Stephan; Alansari, Shehab; Oklu, Rahmi
2015-06-19
Adrenal vein sampling (AVS) is the gold standard test to determine unilateral causes of primary aldosteronism (PA). We have retrospectively characterized our experience with AVS including concordance of AVS results and imaging, and describe the approach for the PA patient in whom bilateral AVS is unsuccessful. We reviewed the medical records of 85 patients with PA and compared patients who were treated medically and surgically on pre-procedure presentation and post-treatment outcomes, and evaluated how technically unsuccessful AVS results were used in further patient management. Out of the 92 AVS performed in 85 patients, AVS was technically successful bilaterally in 58 (63%) of cases. Either unsuccessful AVS prompted a repeat AVS, or results from the contralateral side and from CT imaging were used to guide further therapy. Patients who were managed surgically with adrenalectomy had higher initial blood pressure and lower potassium levels compared with patients who were managed medically. Adrenalectomy results in significantly decreased blood pressure and normalization of potassium levels. AVS can identify surgically curable causes of PA, but can be technically challenging. When one adrenal vein fails to be cannulated, results from the contralateral vein can be useful in conjunction with imaging and clinical findings to suggest further management.
de Vries, Tamar I; Monroe, Glen R; van Belzen, Martine J; van der Lans, Christian A; Savelberg, Sanne Mc; Newman, William G; van Haaften, Gijs; Nievelstein, Rutger A; van Haelst, Mieke M
2016-08-01
Rubinstein-Taybi syndrome (RTS, OMIM 180849) and Filippi syndrome (FLPIS, OMIM 272440) are both rare syndromes, with multiple congenital anomalies and intellectual deficit (MCA/ID). We present a patient with intellectual deficit, short stature, bilateral syndactyly of hands and feet, broad thumbs, ocular abnormalities, and dysmorphic facial features. These clinical features suggest both RTS and FLPIS. Initial DNA analysis of DNA isolated from blood did not identify variants to confirm either of these syndrome diagnoses. Whole-exome sequencing identified a homozygous variant in C9orf173, which was novel at the time of analysis. Further Sanger sequencing analysis of FLPIS cases tested negative for CKAP2L variants did not, however, reveal any further variants. Subsequent analysis using DNA isolated from buccal mucosa revealed a mosaic variant in CREBBP. This report highlights the importance of excluding mosaic variants in patients with a strong but atypical clinical presentation of a MCA/ID syndrome if no disease-causing variants can be detected in DNA isolated from blood samples. As the striking syndactyly observed in the present case is typical for FLPIS, we suggest CREBBP analysis in saliva samples for FLPIS syndrome cases in which no causal CKAP2L variant is detected.
Kitchen, A D; Newham, J A
2011-05-01
Whilst some of the assays used for serological screening of post-mortem blood samples from deceased tissue donors in some countries have been specifically validated by the manufacturer for this purpose, a significant number of those currently in use globally have not. Although specificity has previously been considered a problem in the screening of such samples, we believe that ensuring sensitivity is more important. The aim of this study was to validate a broader range of assays for the screening of post-mortem blood samples from deceased tissue donors. Six microplate immunoassays currently in use within National Health Service Blood and Transplant (NHSBT) for the screening of blood, tissue and stem cell donations were included. Representative samples from confirmed positive donors were titrated in screen negative post-mortem samples in parallel with normal pooled negative serum to determine if there was any inhibition with the post-mortem samples. There were no significant differences seen (P < 0.005) between the dilution curves obtained for the positive samples diluted in post-mortem samples and normal pooled sera. Although small numbers of samples were studied, it can be surmised that the post-mortem blood samples from deceased tissue donors, collected according to United Kingdom guidelines, are a suitable substrate for the assays evaluated. No diminution of reactivity was seen when dilution with sera from deceased donors was compared to dilution using pooled serum from live donors. In the absence of genuine low titre positive post-mortem samples, the use of samples spiked with various levels of target material provides a means of qualifying serological screening assays used by NHSBT for the screening of post-mortem blood samples from deceased tissue donors.
Martinez-Serra, Jordi; Robles, Juan; Nicolàs, Antoni; Gutierrez, Antonio; Ros, Teresa; Amat, Juan Carlos; Alemany, Regina; Vögler, Oliver; Abelló, Aina; Noguera, Aina; Besalduch, Joan
2014-01-01
Blood samples are extensively used for the molecular diagnosis of many hematological diseases. The daily practice in a clinical laboratory of molecular diagnosis in hematology involves using a variety of techniques, based on the amplification of nucleic acids. Current methods for polymerase chain reaction (PCR) use purified genomic DNA, mostly isolated from total peripheral blood cells or white blood cells (WBC). In this paper we describe a real-time fluorescence resonance energy transfer-based method for genotyping directly from blood cells. Our strategy is based on an initial isolation of the WBCs, allowing the removal of PCR inhibitors, such as the heme group, present in the erythrocytes. Once the erythrocytes have been lysed, in the LightCycler(®) 2.0 Instrument, we perform a real-time PCR followed by a melting curve analysis for different genes (Factors 2, 5, 12, MTHFR, and HFE). After testing 34 samples comparing the real-time crossing point (CP) values between WBC (5×10(6) WBC/mL) and purified DNA (20 ng/μL), the results for F5 Leiden were as follows: CP mean value for WBC was 29.26±0.566 versus purified DNA 24.79±0.56. Thus, when PCR was performed from WBC (5×10(6) WBC/mL) instead of DNA (20 ng/μL), we observed a delay of about 4 cycles. These small differences in CP values were similar for all genes tested and did not significantly affect the subsequent analysis by melting curves. In both cases the fluorescence values were high enough, allowing a robust genotyping of all these genes without a previous DNA purification/extraction.
Borena, Wegene; Hofer, Tamara; Stiasny, Karin; Aberle, Stephan W; Gaber, Manfred; von Laer, Dorothee; Schennach, Harald
2017-01-01
Previous studies have shown that Zika virus can infect and be transmitted by A. albopictus. The World Health organization (WHO) has raised concerns of autochthonous transmission of the virus in regions where the vector is endemic. The aim of this pilot study was to assess the occurrence of Zika virus (ZIKV) in western Austria (Tyrol) especially after a history of travel to A. albopictus endemic regions. The study participants were healthy blood donors at randomly selected donation sites in the west Austrian region Tyrol. Rest blood (plasma) samples were tested for the presence of ZIKV nucleic acid and antibodies against the virus. Mean age of the study participants was 44.6 (SD = 12.9) and 58.8% were men. Eighty percent reported to have received vaccine against TBEV, whereas only 4.9 and 0.9% had received YFV and JEV vaccines. Three out of 1001 (0.03%) participants tested positive solely for ZIKV IgM antibody but not for other flaviviruses. Only one individual had ZIKV IgG antibody. All four donors were negative in the neutralization (confirmation) assay. No viral RNA was detected in any of the samples. The null finding of our study refutes WHO's initial fear of global expansion of ZIKV infection including its occurrence in Europe. There appears to be no urgent need to introduce universal screening of donated blood for ZIKV in central Europe at least until the next warm season. Further, Euroimmun anti-Zika ELISA proved to be a highly suitable and reliable test system in populations with high prevalence of TBEV infection and/or immunization.
Stability of 26 Sedative Hypnotics in Six Toxicological Matrices at Different Storage Conditions.
Mata, Dani C
2016-10-01
Forensic laboratories are challenged with backlogs that produce turnaround times that vary from days to months. Therefore, drug stability is important for interpretation in both antemortem (blood and urine) and postmortem (blood, brain, liver, stomach contents) cases. In this study, 23 benzodiazepines (2-hydroxyethylflurazepam, 7-aminoclonazepam, 7-aminoflunitrazepam, α-hydroxyalprazolam, α-hydroxytriazolam, alprazolam, bromazepam, chlordiazepoxide, clonazepam, demoxepam, desalkylflurazepam, diazepam, estazolam, flunitrazepam, flurazepam, lorazepam, midazolam, nitrazepam, nordiazepam, oxazepam, phenazepam, temazepam and triazolam) and three sedative hypnotics (zaleplon, zopiclone and zolpidem) were spiked into the six matrices at two different concentrations for each drug. The samples were stored in either a refrigerator (4°C) or freezer (-20°C) and analyzed in triplicate at various time intervals over an 8-month period using an SWGTOX validated method. The concentrations decreased over time regardless of the initial spiked concentration, and the storage conditions had little effect on the decrease of most drugs. Conversion from drug to metabolite was difficult to determine since all 26 drugs were present in each sample. Zopiclone and phenazepam were the least stable drugs; zopiclone was the only drug that completely disappeared in any matrix (both antemortem and postmortem blood). Urine was the most stable matrix with only phenazepam, 7-aminoclonazepam, 7-aminoflunitrazepam, 2-hydroxyethylflurazepam, and zopiclone decreasing >20% over the 8 months in either storage condition. Postmortem blood, the least stable matrix, had only two drugs, zolpidem and bromazepam, decreasing <20% in the 8-month time period. Further experiments on stability of these drugs should be undertaken to remove the freeze-thaw cycle effect and more thoroughly examining drug-metabolite conversion. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Mitra, Biswadev; Cameron, Peter A; Gruen, Russell L; Mori, Alfredo; Fitzgerald, Mark; Street, Alison
2011-06-01
'Massive' transfusion is a poorly defined inclusion criteria for studies examining the blood and blood product that are used during trauma resuscitation. We aimed to compare the traditional definition of massive transfusion (≥10 units in 24 h) to a more acute definition of at least 5 units in 4 h. Multitrauma patients were subgrouped according to the traditional definition and compared with the acute definition. Demographics, presenting vital signs and blood results, management including transfusion practice and outcomes were retrospectively studied. Associations of transfused fresh frozen plasma:packed red blood cells (PRBC) ratios with mortality were studied. There were 927 patients who received PRBCs in the first 24 h, with 314 patients identified using the traditional definition and 303 patients using the acute definition. The patients identified using the traditional definition received 18 (12-29) units of PRBC in 24 h, significantly higher than those identified using the acute definition [15 (9-29) units, P<0.001]. The traditional definition excluded a significant proportion of patients who died in the emergency department. By using the acute definition to select a study sample, there seems to be an increase in mortality with fresh frozen plasma:PRBC ratio of 1 : 1 ratio compared with a 1 : 2 ratio. The traditional 'massive' transfusion definition not only 'dilutes' the potential study samples with a less acute group of patients, but also further excludes patients who die early. This latter group is most likely to be benefitted from any change to resuscitation practice. An acute definition of massive transfusion should be adopted when examining clinical practice during initial trauma resuscitation.
Sudhakaran, R; Mekata, T; Kono, T; Supamattaya, K; Linh, N T H; Suzuki, Y; Sakai, M; Itami, T
2009-07-01
White spot syndrome virus (WSSV) is an important shrimp pathogen responsible for large economic losses for the shrimp culture industry worldwide. The nucleic acids of the virus must be adequately preserved and transported from the field to the laboratory before molecular diagnostic analysis is performed. Here, we developed a new method to isolate WSSV-DNA using Flinders Technology Associates filter paper (FTA matrix card; Whatman) without centrifugation or hazardous steps involved. FTA technology is a new method allowing the simple collection, shipment and archiving of nucleic acids from haemolymph samples providing DNA protection against nucleases, oxidation, UV damage, microbial and fungal attack. DNA samples prepared from 10-fold dilutions of moribund shrimp haemolymph using FTA matrix cards were analysed using semi-quantitative and quantitative polymerase chain reaction (PCR) and were compared with two commercially available DNA isolation methods, the blood GenomicPrep Mini Spin Kit (GE Healthcare) and the DNAzol (Invitrogen). Sequence analysis was performed for the DNA samples prepared using the various isolation procedures and no differences in the sequence among these methods were identified. Results based on the initial copy number of DNA prepared from the GenomicPrep Mini Spin Kit are a little more sensitive than the DNA prepared from FTA matrix cards, whereas the DNAzol method is not suitable for blood samples. Our data shows the efficiency of retention capacity of WSSV-DNA samples from impregnated FTA matrix cards. Matrix cards were easy to store and ship for long periods of time. They provide ease of handling and are a reliable alternative for sample collection and for molecular detection and characterization of WSSV isolates.
Corkill, David
2012-02-01
Haemolysed blood samples are an unnecessary burden on Emergency Departments (ED) as they increase workloads and drive down efficiencies. Little empirical data exists that demonstrates the effectiveness of educational posters displayed in staff toilet cubicles. This study explored the impact educational toilet posters have on reducing haemolysis rates within the ED. A time series study of the clinical effect of educational toilet posters on reducing haemolysis rates throughout a 12 month period at the Gold Coast Hospital ED was undertaken. The GCH ED is a tertiary emergency service that has approximately 66,000 patient presentations per year. Data was collected prospectively. Analysis was undertaken to investigate the effects on total number of haemolysed samples and those clinically significant samples with a haemolytic index >3. Further investigation explored the specific effects on medical and nursing staff. Analysis undertaken using an independent t-test found that the pre-intervention data demonstrates a medium haemolysis rate of 4.92% (SD=1.04). This is a statistically significantly different (t=3.56, df=50, p=0.001) from the median post intervention data of 3.95% (SD=0.84). The difference of 0.97% (95%CI=0.42, 1.52) represents a 19.72% reduction in clinically significant haemolysed samples over the study period. This study reveals that the use of educational toilet posters had a positive impact on reducing the rates of haemolysed samples collected within the ED. This simple and cost effective educational initiative changed the behaviour of clinical staff. Further investigation is warranted to examine the impact of educational toilet posters on additional clinical scenarios. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.
Feng, Lei; Li, Cai-Xia; Han, Jun-Ping; Xu, Cheng; Hu, Lan
2015-11-01
To obtain single-source short tandem repeat (STR) profiles in trace female/male blood mixture samples, we combined florescence in situ hybridization (FISH), laser microdissection, and low volume PCR (LV-PCR) to isolate male/female cells and improve sensitivity. The results showed that isolation of as few as 10 leukocytes was sufficient to yield full STR profiles in fresh female or male blood samples for 32 independent tests with a low additional alleles rate (3.91%) and drop-out alleles rate (5.01%). Moreover, this procedure was tested in two fresh blood mixture series at three ratios (1:5, 1:10, and 1:20), two mock female/male blood mixture casework samples, and one practical casework sample. Male and female STR profiles were successfully detected in all of these samples, showing that this procedure could be used in forensic casework in the future.
Vallinoto, Antonio C R; Aguiar, Samantha; Sá, Keyla G; Freitas, Felipe Bonfim; Ferreira, Glenda; Lima, Sandra Souza; Hermes, Renata Bezerra; Machado, Luiz Fernando Almeida; Cayres-Vallinoto, Izaura; Ishak, Marluísa; Ishak, Ricardo
2016-07-01
Human immunodeficiency virus 1 (HIV-1) infection is a global public health problem, but, so far, there is no published information regarding the epidemiology of HIV-1 in Marajó Archipelago (Pará, Brazil). The present study reports the occurrence of infection by HIV-1 in four municipalities of the Marajó Island, Pará, Brazil. A total of 1877 samples were collected from volunteer blood donors (1296 women and 551 men) living in the municipalities of Anajás, Chaves, Portel and São Sebastião da Boa Vista. Information about risk behaviour assessment was obtained from a questionnaire. Plasma samples were tested for the presence of anti-HIV antibodies using serological tests. The infection was confirmed by nucleic acid amplification assays. Twelve samples were seropositive for HIV by ELISA. Western blot analysis showed four positive samples, eight indeterminate patterns and one found to be negative. Molecular analysis revealed three positive samples. Risk factors for HIV-1 infection included absence of condoms during sexual intercourse (41.3%, São Sebastião da Boa Vista), use of illicit drugs (5.8%, Anajás) and early initiation of sexual activities, from 10-15 years (30.7%). Although the study indicates a low HIV-1 prevalence in Marajó Island, some factors may increase the risk for HIV-1 and these include early sexual initiation, unprotected sexual intercourse and the use of illicit drugs.
Păstrav, Ioana Raluca; Ionică, Angela Monica; Peştean, Cosmin; Novakova, Eva; Modrý, David; Mihalca, Andrei Daniel
2018-06-15
Dirofilaria immitis and D. repens are mosquito-borne nematodes, primarily infecting dogs, but also other species of carnivores and even humans. Given their impact on animal and human health, the transmission of these filarioids has been widely studied. The microfilariaemia has been shown to have a circadian variation for both Dirofilaria species infecting dogs. Due to methodological difficulties, the periodicity was only studied using venous blood samples, while the mosquitoes feed, in fact, on capillary blood. In this context, the present study aimed to test the feasibility of using triatomine bugs for the collection of capillary blood and to comparatively evaluate the level of microfilariaemia and its circadian variation in capillary blood vs. peripheral venous blood in a dog naturally co-infected with D. immitis and D. repens. The results showed a feeding success of 50%, with variations in the blood meal volume that the bugs ingested. The relative values of microfilariaemia (mf/bug) were strongly correlated with the volume of blood recovered: the more blood recovered from each bug, the higher values of microfilariaemia in the evening samples while the opposite results were obtained for the morning samples. The counting of microfilariae revealed a dominance of D. immitis in all the samples, but with significantly higher microfilariaemia in the venous blood. Meanwhile, for D. repens, the situation was opposite, with higher counts in the capillary blood samples. Our study showed that triatomine bugs can be used as a model for the collection and study of microfilariaemia in the capillary blood in mammals. Copyright © 2018 Elsevier B.V. All rights reserved.
Too, D; Wakayama, E J; Locati, L L; Landwer, G E
1998-09-01
The purpose of this investigation was to document the effect of a 10-wk precompetition bodybuilding diet and training, on blood chemistry and body composition. One adult male, steroid and drug free, preparing for a first competition. Average daily dietary intake consisted of 2263 calories (71% protein, 16% carbohydrate, 13% fats), with a protein intake of 5.0 gm.kg-1 body mass (BM). Initial body weight of 76.3 kgf (16% body fat) decreased to 63.4 kgf (4.4% body fat). Blood samples for electrolytes, TP, Alb, bilirubin, LDL-C, TG, UA, and amylase were normal. HDL-C levels increased from 65 to 89 mg.dL-1. Decreased glucose levels (< 50 mg.dL-1), indicated hypoglycemia. Increased Mg, LD, and CK levels indicated intense training. Increased inorganic phosphorus from 3.7 to 8.2 mg.dL-1 suggested lactic acidosis. Increased BUN levels from 16 to 53 mg.dL-1 and creatinine from 1.1 to 1.8 mg.dL-1 may be attributed to a high protein diet. However, heart muscle enzyme (CK-MB) was not elevated. Substantial changes in body composition and blood chemistry suggest adequate nutrition be ensured, and caution taken to avoid excessive physiologic stresses on the body during precompetition diet and training.
Wang, Yaokun; Yan, Mingyang
2017-01-01
Hierarchical copper shells anchored on magnetic nanoparticles were designed and fabricated to selectively deplete hemoglobin from human blood by immobilized metal affinity chromatography. Briefly, CoFe2O4 nanoparticles coated with polyacrylic acid were first synthesized by a one-pot solvothermal method. Hierarchical copper shells were then deposited by immobilizing Cu2+ on nanoparticles and subsequently by reducing between the solid CoFe2O4@COOH and copper solution with NaBH4. The resulting nanoparticles were characterized by scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectrometry, X-ray photoelectron spectroscopy, and vibrating sample magnetometry. The particles were also tested against purified bovine hemoglobin over a range of pH, contact time, and initial protein concentration. Hemoglobin adsorption followed pseudo-second-order kinetics and reached equilibrium in 90 min. Isothermal data also fit the Langmuir model well, with calculated maximum adsorption capacity 666 mg g−1. Due to the high density of Cu2+ on the shell, the nanoparticles efficiently and selectively deplete hemoglobin from human blood. Taken together, the results demonstrate that the particles with hierarchical copper shells effectively remove abundant, histidine-rich proteins, such as hemoglobin from human blood, and thereby minimize interference in diagnostic and other assays. PMID:28316987
Zhao, Mingrui; Schwartz, Theodore H.
2013-01-01
Traditional models of ictal propagation involve the concept of an initiation site and a progressive outward march of activation. The process of neurovascular coupling, whereby the brain supplies oxygenated blood to metabolically active neurons presumably results in a similar outward cascade of hyperemia. However, ictal neurovascular coupling has never been assessed in vivo using simultaneous measurements of membrane potential change and hyperemia with wide spatial sampling. In an acute rat ictal model, using simultaneous intrinsic optical signal (IOS) and voltage-sensitive dye (VSD) imaging of cerebral blood volume and membrane potential changes, we demonstrate that seizures consist of multiple dynamic multidirectional waves of membrane potential change with variable onset sites that spread through a widespread network. Local blood volume evolves on a much slower spatiotemporal scale. At seizure onset, the VSD waves extend beyond the IOS signal. During evolution, spatial correlation with hemodynamic signal only exists briefly at the maximal spread of the VSD signal. At termination, the IOS signal extends spatially and temporally beyond the VSD waves. Hence, vascular reactivity evolves in a separate but parallel fashion to membrane potential changes resulting in a mechanism of neurovascular coupling and uncoupling, which is as dynamic as the seizure itself. PMID:22499798
Dukić, Lora; Simundić, Ana-Maria
2014-01-01
The aim of this survey study was to assess the current practices and policies in use related to the various steps in the blood gas testing process, across hospital laboratories in Croatia. First questionnaire was sent by email to all medical biochemistry laboratories (N = 104) within general, specialized and clinical hospitals and university hospital centres to identify laboratories which perform blood gas analysis. Second questionnaire with detailed questions about sample collection, analysis and quality control procedures, was sent only to 47 laboratories identified by the first survey. Questionnaire was designed as combination of questions and statements with Likert scale. Third questionnaire was sent to all participating laboratories (N=47) for additional clarification for either indeterminate or unclear answers. Blood gas analysis is performed in 47/104 hospital laboratories in Croatia. In 25/41 (0.61) of the laboratories capillary blood gas sampling is the preferred sample type for adult patient population, whereas arterial blood sample is preferentially used in only 5/44 laboratories (0.11). Blood sampling and sample processing for capillary samples is done almost always by laboratory technicians (36/41 and 37/44, respectively), whereas arterial blood sampling is almost always done by the physician (24/29) and only rarely by a nurse (5/28). Sample acceptance criteria and sample analysis are in accordance with international recommendations for majority of laboratories. 43/44 laboratories participate in the national EQA program. POCT analyzers are installed outside of the laboratory in 20/47 (0.43) institutions. Laboratory staff is responsible for education and training of ward personnel, quality control and instrument maintenance in only 12/22, 11/20 and 9/20 institutions, respectively. Practices related to collection and analysis for blood gases in Croatia are not standardised and vary substantially between laboratories. POCT analyzers are not under the direct supervision by laboratory personnel in a large proportion of surveyed institutions. Collective efforts should be made to harmonize and improve policies and procedures related to blood gas testing in Croatian laboratories.
78 FR 9708 - National Heart, Lung, and Blood Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-11
... unwarranted invasion of personal privacy. Name of Committee: Heart, Lung, and Blood Initial Review Group... Blood Institute; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory Committee... Branch/DERA, National Heart, Lung, and Blood Institute, 6701 Rockledge Drive, Room 7190, Bethesda, MD...
75 FR 70273 - National Heart, Lung, and Blood Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-17
... unwarranted invasion of personal privacy. Name of Committee: Heart, Lung, and Blood Initial Review Group... Blood Institute; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory Committee... Officer, Review Branch/DERA, National Heart, Lung, and Blood Institute, 6701 Rockledge Drive, Room 7196...
76 FR 5596 - National Heart, Lung, and Blood Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-01
... unwarranted invasion of personal privacy. Name of Committee: Heart, Lung, and Blood Initial Review Group... Blood Institute; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory Committee.../DERA, National Heart, Lung, and Blood Institute, 6701 Rockledge Drive, Room 7190, Bethesda, MD 20892...
77 FR 6571 - National Heart, Lung, and Blood Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-08
... unwarranted invasion of personal privacy. Name of Committee: Heart, Lung, and Blood Initial Review Group... Blood Institute; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory Committee.../DERA, National Heart, Lung, and Blood Institute, 6701 Rockledge Drive, Room 7190, Bethesda, MD 20892...
75 FR 56548 - National Heart, Lung, and Blood Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-16
... unwarranted invasion of personal privacy. Name of Committee: Heart, Lung, and Blood Initial Review Group... Blood Institute; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory Committee.../DERA, National Heart, Lung, and Blood Institute, 6701 Rockledge Drive, Room 7190, Bethesda, MD 20892...
75 FR 29356 - National Heart, Lung, and Blood Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-25
... unwarranted invasion of personal privacy. Name of Committee: Heart, Lung, and Blood Initial Review Group... Blood Institute; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory Committee... Officer, Review Branch/DERA, National Heart, Lung, and Blood Institute, 6701 Rockledge Drive, Room 7196...
76 FR 62422 - National Heart, Lung, and Blood Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-07
... unwarranted invasion of personal privacy. Name of Committee: Heart, Lung, and Blood Initial Review Group... Blood Institute; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory Committee.../DERA, National Heart, Lung, and Blood Institute, 6701 Rockledge Drive, Room 7190, Bethesda, MD 20892...