Sample records for initial imaging study

  1. Downstream Imaging Utilization After Emergency Department Ultrasound Interpreted by Radiologists Versus Nonradiologists: A Medicare Claims-Based Study.

    PubMed

    Allen, Bibb; Carrol, L Van; Hughes, Danny R; Hemingway, Jennifer; Duszak, Richard; Rosenkrantz, Andrew B

    2017-04-01

    To study differences in imaging utilization downstream to initial emergency department (ED) ultrasound examinations interpreted by radiologists versus nonradiologists. Using 5% Medicare Research Identifiable Files from 2009 to 2014, we identified episodes where the place of service was "emergency room hospital" and the patient also underwent an ultrasound examination. We determined whether the initial ultrasound was interpreted by a radiologist or nonradiologist and then summed all additional imaging events occurring within 7, 14, and 30 days of each initial ED ultrasound. For each year and each study window, we calculated the mean number of downstream imaging procedures by specialty group. Of 200,357 ED ultrasound events, 163,569 (81.6%) were interpreted by radiologists and 36,788 (18.4%) by nonradiologists. Across all study years, ED patients undergoing ultrasound examinations interpreted by nonradiologists underwent 1.08, 1.22, and 1.34 additional diagnostic imaging studies at 7, 14, and 30 days, respectively (P < .01) compared with when the initial ultrasound examination was interpreted by a radiologist. From 2010 to 2014, the volume of downstream imaging for both radiologists and nonradiologists significantly decreased, with each year resulting in 0.08 fewer imaging examinations (P < .001) 14 days after the ED ultrasound event. Despite that decline, differences in downstream imaging between radiologists and nonradiologists persisted over time. Downstream imaging after an initial ED ultrasound is significantly reduced when the ultrasound examination is interpreted by a radiologist rather than a nonradiologist. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. Automatic initialization and quality control of large-scale cardiac MRI segmentations.

    PubMed

    Albà, Xènia; Lekadir, Karim; Pereañez, Marco; Medrano-Gracia, Pau; Young, Alistair A; Frangi, Alejandro F

    2018-01-01

    Continuous advances in imaging technologies enable ever more comprehensive phenotyping of human anatomy and physiology. Concomitant reduction of imaging costs has resulted in widespread use of imaging in large clinical trials and population imaging studies. Magnetic Resonance Imaging (MRI), in particular, offers one-stop-shop multidimensional biomarkers of cardiovascular physiology and pathology. A wide range of analysis methods offer sophisticated cardiac image assessment and quantification for clinical and research studies. However, most methods have only been evaluated on relatively small databases often not accessible for open and fair benchmarking. Consequently, published performance indices are not directly comparable across studies and their translation and scalability to large clinical trials or population imaging cohorts is uncertain. Most existing techniques still rely on considerable manual intervention for the initialization and quality control of the segmentation process, becoming prohibitive when dealing with thousands of images. The contributions of this paper are three-fold. First, we propose a fully automatic method for initializing cardiac MRI segmentation, by using image features and random forests regression to predict an initial position of the heart and key anatomical landmarks in an MRI volume. In processing a full imaging database, the technique predicts the optimal corrective displacements and positions in relation to the initial rough intersections of the long and short axis images. Second, we introduce for the first time a quality control measure capable of identifying incorrect cardiac segmentations with no visual assessment. The method uses statistical, pattern and fractal descriptors in a random forest classifier to detect failures to be corrected or removed from subsequent statistical analysis. Finally, we validate these new techniques within a full pipeline for cardiac segmentation applicable to large-scale cardiac MRI databases. The results obtained based on over 1200 cases from the Cardiac Atlas Project show the promise of fully automatic initialization and quality control for population studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Genome-wide association analysis of secondary imaging phenotypes from the Alzheimer's disease neuroimaging initiative study.

    PubMed

    Zhu, Wensheng; Yuan, Ying; Zhang, Jingwen; Zhou, Fan; Knickmeyer, Rebecca C; Zhu, Hongtu

    2017-02-01

    The aim of this paper is to systematically evaluate a biased sampling issue associated with genome-wide association analysis (GWAS) of imaging phenotypes for most imaging genetic studies, including the Alzheimer's Disease Neuroimaging Initiative (ADNI). Specifically, the original sampling scheme of these imaging genetic studies is primarily the retrospective case-control design, whereas most existing statistical analyses of these studies ignore such sampling scheme by directly correlating imaging phenotypes (called the secondary traits) with genotype. Although it has been well documented in genetic epidemiology that ignoring the case-control sampling scheme can produce highly biased estimates, and subsequently lead to misleading results and suspicious associations, such findings are not well documented in imaging genetics. We use extensive simulations and a large-scale imaging genetic data analysis of the Alzheimer's Disease Neuroimaging Initiative (ADNI) data to evaluate the effects of the case-control sampling scheme on GWAS results based on some standard statistical methods, such as linear regression methods, while comparing it with several advanced statistical methods that appropriately adjust for the case-control sampling scheme. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. FTIR Imaging Coupled with Multivariate Analysis for Study of Initial Diffusion of Different Solvents in Cellulose Acetate Butyrate Films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindblad, M.S.; Keyes, B.; Gedvilas, L.

    Fourier transform infrared (FTIR) spectroscopic imaging was used to study the initial diffusion of different solvents in cellulose acetate butyrate (CAB) films containing different amounts of acetyl and butyryl substituents. Different solvents and solvent/non-solvent mixtures were also studied. The FTIR imaging system allowed acquisition of sequential images of the CAB films as solvent penetration proceeded without disturbing the system. The interface between the non-swollen polymer and the initial swelling front could be identified using multivariate data analysis tools. For a series of ketone solvents the initial diffusion coefficients and diffusion rates could be quantified and were found to be relatedmore » to the polar and hydrogen interaction parameters in the Hansen solubility parameters of the solvents. For the solvent/non-solvent system the initial diffusion rate decreased less than linearly with the weight-percent of non-solvent present in the solution, which probably was due to the swelling characteristic of the non-solvent. For a given solvent, increasing the butyryl content of the CAB increased the initial diffusion rate. Increasing the butyryl content from 17 wt.% butyryl to 37 wt.% butyryl produced a considerably larger increase in initial diffusion rate compared to an increase in butyryl content from 37 wt.% to 50 wt.% butyryl.« less

  5. Collaborative Initiative in Biomedical Imaging to Study Complex Diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Weili; Fiddy, Michael A.

    2012-03-31

    The work reported addressed these topics: Fluorescence imaging; Optical coherence tomography; X-ray interferometer/phase imaging system; Quantitative imaging from scattered fields, Terahertz imaging and spectroscopy; and Multiphoton and Raman microscopy.

  6. A longitudinal study about the body image and psychosocial adjustment of breast cancer patients during the course of the disease.

    PubMed

    Moreira, Helena; Canavarro, Maria Cristina

    2010-09-01

    The research of body image among breast cancer patients is characterized by some limitations, such as the lack of longitudinal studies or the absence of a multidimensional perspective of body image. This study intends to overcome these limitations, by examining the evolution of body image dimensions (investment, emotions and evaluations) from the period of surgery (T1) to 6-months after the treatment's ending (T2). It also aims to explore the predictors of body image at T2 and, simultaneously, the predictive role of initial body image to psychosocial adjustment at T2. A total of 56 breast cancer patients participated in both assessments and completed a battery of instruments that included measures of body image dimensions (appearance investment, self-consciousness of appearance, shame and appearance satisfaction) and psychosocial adjustment (quality of life and emotional distress). Within the dimensions of body image, only shame increased over time. In general, initial levels of investment predicted subsequent body image dimensions and having a mastectomy done was associated with higher shame and lower appearance satisfaction at T2. Initial body image did not predict later adjustment, with the exception of depression, where appearance investment played a relevant role. Our findings contributed to the advance of knowledge in this area, providing relevant data about the evolution of body image dimensions, its predictors and its predictive role on psychosocial adjustment among breast cancer patients. This study also suggested some clinical implications that can assist health professionals to implement strategies focused on body image throughout the disease.

  7. Comparison of magnetic resonance imaging and computed tomography in suspected lesions in the posterior cranial fossa.

    PubMed Central

    Teasdale, G. M.; Hadley, D. M.; Lawrence, A.; Bone, I.; Burton, H.; Grant, R.; Condon, B.; Macpherson, P.; Rowan, J.

    1989-01-01

    OBJECTIVE--To compare computed tomography and magnetic resonance imaging in investigating patients suspected of having a lesion in the posterior cranial fossa. DESIGN--Randomised allocation of newly referred patients to undergo either computed tomography or magnetic resonance imaging; the alternative investigation was performed subsequently only in response to a request from the referring doctor. SETTING--A regional neuroscience centre serving 2.7 million. PATIENTS--1020 Patients recruited between April 1986 and December 1987, all suspected by neurologists, neurosurgeons, or other specialists of having a lesion in the posterior fossa and referred for neuroradiology. The groups allocated to undergo computed tomography or magnetic resonance imaging were well matched in distributions of age, sex, specialty of referring doctor, investigation as an inpatient or an outpatient, suspected site of lesion, and presumed disease process; the referring doctor's confidence in the initial clinical diagnosis was also similar. INTERVENTIONS--After the patients had been imaged by either computed tomography or magnetic resonance (using a resistive magnet of 0.15 T) doctors were given the radiologist's report and a form asking if they considered that imaging with the alternative technique was necessary and, if so, why; it also asked for their current diagnoses and their confidence in them. MAIN OUTCOME MEASURES--Number of requests for the alternative method of investigation. Assessment of characteristics of patients for whom further imaging was requested and lesions that were suspected initially and how the results of the second imaging affected clinicians' and radiologists' opinions. RESULTS--Ninety three of the 501 patients who initially underwent computed tomography were referred subsequently for magnetic resonance imaging whereas only 28 of the 493 patients who initially underwent magnetic resonance imaging were referred subsequently for computed tomography. Over the study the number of patients referred for magnetic resonance imaging after computed tomography increased but requests for computed tomography after magnetic resonance imaging decreased. The reason that clinicians gave most commonly for requesting further imaging by magnetic resonance was that the results of the initial computed tomography failed to exclude their suspected diagnosis (64 patients). This was less common in patients investigated initially by magnetic resonance imaging (eight patients). Management of 28 patients (6%) imaged initially with computed tomography and 12 patients (2%) imaged initially with magnetic resonance was changed on the basis of the results of the alternative imaging. CONCLUSIONS--Magnetic resonance imaging provided doctors with the information required to manage patients suspected of having a lesion in the posterior fossa more commonly than computed tomography, but computed tomography alone was satisfactory in 80% of cases... PMID:2506965

  8. Edge-oriented dual-dictionary guided enrichment (EDGE) for MRI-CT image reconstruction.

    PubMed

    Li, Liang; Wang, Bigong; Wang, Ge

    2016-01-01

    In this paper, we formulate the joint/simultaneous X-ray CT and MRI image reconstruction. In particular, a novel algorithm is proposed for MRI image reconstruction from highly under-sampled MRI data and CT images. It consists of two steps. First, a training dataset is generated from a series of well-registered MRI and CT images on the same patients. Then, an initial MRI image of a patient can be reconstructed via edge-oriented dual-dictionary guided enrichment (EDGE) based on the training dataset and a CT image of the patient. Second, an MRI image is reconstructed using the dictionary learning (DL) algorithm from highly under-sampled k-space data and the initial MRI image. Our algorithm can establish a one-to-one correspondence between the two imaging modalities, and obtain a good initial MRI estimation. Both noise-free and noisy simulation studies were performed to evaluate and validate the proposed algorithm. The results with different under-sampling factors show that the proposed algorithm performed significantly better than those reconstructed using the DL algorithm from MRI data alone.

  9. The Holistic Processing Account of Visual Expertise in Medical Image Perception: A Review

    PubMed Central

    Sheridan, Heather; Reingold, Eyal M.

    2017-01-01

    In the field of medical image perception, the holistic processing perspective contends that experts can rapidly extract global information about the image, which can be used to guide their subsequent search of the image (Swensson, 1980; Nodine and Kundel, 1987; Kundel et al., 2007). In this review, we discuss the empirical evidence supporting three different predictions that can be derived from the holistic processing perspective: Expertise in medical image perception is domain-specific, experts use parafoveal and/or peripheral vision to process large regions of the image in parallel, and experts benefit from a rapid initial glimpse of an image. In addition, we discuss a pivotal recent study (Litchfield and Donovan, 2016) that seems to contradict the assumption that experts benefit from a rapid initial glimpse of the image. To reconcile this finding with the existing literature, we suggest that global processing may serve multiple functions that extend beyond the initial glimpse of the image. Finally, we discuss future research directions, and we highlight the connections between the holistic processing account and similar theoretical perspectives and findings from other domains of visual expertise. PMID:29033865

  10. The Holistic Processing Account of Visual Expertise in Medical Image Perception: A Review.

    PubMed

    Sheridan, Heather; Reingold, Eyal M

    2017-01-01

    In the field of medical image perception, the holistic processing perspective contends that experts can rapidly extract global information about the image, which can be used to guide their subsequent search of the image (Swensson, 1980; Nodine and Kundel, 1987; Kundel et al., 2007). In this review, we discuss the empirical evidence supporting three different predictions that can be derived from the holistic processing perspective: Expertise in medical image perception is domain-specific, experts use parafoveal and/or peripheral vision to process large regions of the image in parallel, and experts benefit from a rapid initial glimpse of an image. In addition, we discuss a pivotal recent study (Litchfield and Donovan, 2016) that seems to contradict the assumption that experts benefit from a rapid initial glimpse of the image. To reconcile this finding with the existing literature, we suggest that global processing may serve multiple functions that extend beyond the initial glimpse of the image. Finally, we discuss future research directions, and we highlight the connections between the holistic processing account and similar theoretical perspectives and findings from other domains of visual expertise.

  11. Kinetic Analysis of Benign and Malignant Breast Lesions With Ultrafast Dynamic Contrast-Enhanced MRI: Comparison With Standard Kinetic Assessment.

    PubMed

    Abe, Hiroyuki; Mori, Naoko; Tsuchiya, Keiko; Schacht, David V; Pineda, Federico D; Jiang, Yulei; Karczmar, Gregory S

    2016-11-01

    The purposes of this study were to evaluate diagnostic parameters measured with ultrafast MRI acquisition and with standard acquisition and to compare diagnostic utility for differentiating benign from malignant lesions. Ultrafast acquisition is a high-temporal-resolution (7 seconds) imaging technique for obtaining 3D whole-breast images. The dynamic contrast-enhanced 3-T MRI protocol consists of an unenhanced standard and an ultrafast acquisition that includes eight contrast-enhanced ultrafast images and four standard images. Retrospective assessment was performed for 60 patients with 33 malignant and 29 benign lesions. A computer-aided detection system was used to obtain initial enhancement rate and signal enhancement ratio (SER) by means of identification of a voxel showing the highest signal intensity in the first phase of standard imaging. From the same voxel, the enhancement rate at each time point of the ultrafast acquisition and the AUC of the kinetic curve from zero to each time point of ultrafast imaging were obtained. There was a statistically significant difference between benign and malignant lesions in enhancement rate and kinetic AUC for ultrafast imaging and also in initial enhancement rate and SER for standard imaging. ROC analysis showed no significant differences between enhancement rate in ultrafast imaging and SER or initial enhancement rate in standard imaging. Ultrafast imaging is useful for discriminating benign from malignant lesions. The differential utility of ultrafast imaging is comparable to that of standard kinetic assessment in a shorter study time.

  12. Automated imaging system for single molecules

    DOEpatents

    Schwartz, David Charles; Runnheim, Rodney; Forrest, Daniel

    2012-09-18

    There is provided a high throughput automated single molecule image collection and processing system that requires minimal initial user input. The unique features embodied in the present disclosure allow automated collection and initial processing of optical images of single molecules and their assemblies. Correct focus may be automatically maintained while images are collected. Uneven illumination in fluorescence microscopy is accounted for, and an overall robust imaging operation is provided yielding individual images prepared for further processing in external systems. Embodiments described herein are useful in studies of any macromolecules such as DNA, RNA, peptides and proteins. The automated image collection and processing system and method of same may be implemented and deployed over a computer network, and may be ergonomically optimized to facilitate user interaction.

  13. Photoacoustic imaging in both soft and hard biological tissue

    NASA Astrophysics Data System (ADS)

    Li, T.; Dewhurst, R. J.

    2010-03-01

    To date, most Photoacoustic (PA) imaging results have been from soft biotissues. In this study, a PA imaging system with a near-infrared pulsed laser source has been applied to obtain 2-D and 3-D images from both soft tissue and post-mortem dental samples. Imaging results showed that the PA technique has the potential to image human oral disease, such as early-stage teeth decay. For non-invasive photoacoustic imaging, the induced temperature and pressure rises within biotissues should not cause physical damage to the tissue. Several simulations based on the thermoelastic effect have been applied to predict initial temperature and pressure fields within a tooth sample. Predicted initial temperature and pressure rises are below corresponding safety limits.

  14. North by Northwestern: initial experience with PACS at Northwestern Memorial Hospital

    NASA Astrophysics Data System (ADS)

    Channin, David S.; Hawkins, Rodney C.; Enzmann, Dieter R.

    2000-05-01

    This paper describes the initial phases and configuration of the Picture Archive and Communication System (PACS) deployed at Northwestern Memorial Hospital. The primary goals of the project were to improve service to patients, improve service to referring physicians, and improve the process of radiology. Secondary goals were to enhance the academic mission, and modernize institutional information systems. The system consists of a large number of heterogeneous imaging modalities sending imaging studies via DICOM to a GE medical Systems PathSpeed PACS. The radiology department workflow is briefly described. The system is currently storing approximately 140,000 studies and over 5 million images, growing by approximately 600 studies and 25,000 images per day. Data reflecting use of the short term and long term storage is provided.

  15. Iterative reconstruction for CT perfusion with a prior-image induced hybrid nonlocal means regularization: Phantom studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Bin; Lyu, Qingwen; Ma, Jianhua

    2016-04-15

    Purpose: In computed tomography perfusion (CTP) imaging, an initial phase CT acquired with a high-dose protocol can be used to improve the image quality of later phase CT acquired with a low-dose protocol. For dynamic regions, signals in the later low-dose CT may not be completely recovered if the initial CT heavily regularizes the iterative reconstruction process. The authors propose a hybrid nonlocal means (hNLM) regularization model for iterative reconstruction of low-dose CTP to overcome the limitation of the conventional prior-image induced penalty. Methods: The hybrid penalty was constructed by combining the NLM of the initial phase high-dose CT inmore » the stationary region and later phase low-dose CT in the dynamic region. The stationary and dynamic regions were determined by the similarity between the initial high-dose scan and later low-dose scan. The similarity was defined as a Gaussian kernel-based distance between the patch-window of the same pixel in the two scans, and its measurement was then used to weigh the influence of the initial high-dose CT. For regions with high similarity (e.g., stationary region), initial high-dose CT played a dominant role for regularizing the solution. For regions with low similarity (e.g., dynamic region), the regularization relied on a low-dose scan itself. This new hNLM penalty was incorporated into the penalized weighted least-squares (PWLS) for CTP reconstruction. Digital and physical phantom studies were performed to evaluate the PWLS-hNLM algorithm. Results: Both phantom studies showed that the PWLS-hNLM algorithm is superior to the conventional prior-image induced penalty term without considering the signal changes within the dynamic region. In the dynamic region of the Catphan phantom, the reconstruction error measured by root mean square error was reduced by 42.9% in PWLS-hNLM reconstructed image. Conclusions: The PWLS-hNLM algorithm can effectively use the initial high-dose CT to reconstruct low-dose CTP in the stationary region while reducing its influence in the dynamic region.« less

  16. Cost-effectiveness of angiographic imaging in isolated perimesencephalic subarachnoid hemorrhage.

    PubMed

    Kalra, Vivek B; Wu, Xiao; Forman, Howard P; Malhotra, Ajay

    2014-12-01

    The purpose of this study is to perform a comprehensive cost-effectiveness analysis of all possible permutations of computed tomographic angiography (CTA) and digital subtraction angiography imaging strategies for both initial diagnosis and follow-up imaging in patients with perimesencephalic subarachnoid hemorrhage on noncontrast CT. Each possible imaging strategy was evaluated in a decision tree created with TreeAge Pro Suite 2014, with parameters derived from a meta-analysis of 40 studies and literature values. Base case and sensitivity analyses were performed to assess the cost-effectiveness of each strategy. A Monte Carlo simulation was conducted with distributional variables to evaluate the robustness of the optimal strategy. The base case scenario showed performing initial CTA with no follow-up angiographic studies in patients with perimesencephalic subarachnoid hemorrhage to be the most cost-effective strategy ($5422/quality adjusted life year). Using a willingness-to-pay threshold of $50 000/quality adjusted life year, the most cost-effective strategy based on net monetary benefit is CTA with no follow-up when the sensitivity of initial CTA is >97.9%, and CTA with CTA follow-up otherwise. The Monte Carlo simulation reported CTA with no follow-up to be the optimal strategy at willingness-to-pay of $50 000 in 99.99% of the iterations. Digital subtraction angiography, whether at initial diagnosis or as part of follow-up imaging, is never the optimal strategy in our model. CTA without follow-up imaging is the optimal strategy for evaluation of patients with perimesencephalic subarachnoid hemorrhage when modern CT scanners and a strict definition of perimesencephalic subarachnoid hemorrhage are used. Digital subtraction angiography and follow-up imaging are not optimal as they carry complications and associated costs. © 2014 American Heart Association, Inc.

  17. Performance evaluation of algebraic reconstruction technique (ART) for prototype chest digital tomosynthesis (CDT) system

    NASA Astrophysics Data System (ADS)

    Lee, Haenghwa; Choi, Sunghoon; Jo, Byungdu; Kim, Hyemi; Lee, Donghoon; Kim, Dohyeon; Choi, Seungyeon; Lee, Youngjin; Kim, Hee-Joung

    2017-03-01

    Chest digital tomosynthesis (CDT) is a new 3D imaging technique that can be expected to improve the detection of subtle lung disease over conventional chest radiography. Algorithm development for CDT system is challenging in that a limited number of low-dose projections are acquired over a limited angular range. To confirm the feasibility of algebraic reconstruction technique (ART) method under variations in key imaging parameters, quality metrics were conducted using LUNGMAN phantom included grand-glass opacity (GGO) tumor. Reconstructed images were acquired from the total 41 projection images over a total angular range of +/-20°. We evaluated contrast-to-noise ratio (CNR) and artifacts spread function (ASF) to investigate the effect of reconstruction parameters such as number of iterations, relaxation parameter and initial guess on image quality. We found that proper value of ART relaxation parameter could improve image quality from the same projection. In this study, proper value of relaxation parameters for zero-image (ZI) and back-projection (BP) initial guesses were 0.4 and 0.6, respectively. Also, the maximum CNR values and the minimum full width at half maximum (FWHM) of ASF were acquired in the reconstructed images after 20 iterations and 3 iterations, respectively. According to the results, BP initial guess for ART method could provide better image quality than ZI initial guess. In conclusion, ART method with proper reconstruction parameters could improve image quality due to the limited angular range in CDT system.

  18. Large deformation image classification using generalized locality-constrained linear coding.

    PubMed

    Zhang, Pei; Wee, Chong-Yaw; Niethammer, Marc; Shen, Dinggang; Yap, Pew-Thian

    2013-01-01

    Magnetic resonance (MR) imaging has been demonstrated to be very useful for clinical diagnosis of Alzheimer's disease (AD). A common approach to using MR images for AD detection is to spatially normalize the images by non-rigid image registration, and then perform statistical analysis on the resulting deformation fields. Due to the high nonlinearity of the deformation field, recent studies suggest to use initial momentum instead as it lies in a linear space and fully encodes the deformation field. In this paper we explore the use of initial momentum for image classification by focusing on the problem of AD detection. Experiments on the public ADNI dataset show that the initial momentum, together with a simple sparse coding technique-locality-constrained linear coding (LLC)--can achieve a classification accuracy that is comparable to or even better than the state of the art. We also show that the performance of LLC can be greatly improved by introducing proper weights to the codebook.

  19. TIME-SEQUENCED X-RAY OBSERVATION OF A THERMAL EXPLOSION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tringe, J. W.; Molitoris, J. D.; Kercher, J. R.

    The evolution of a thermally-initiated explosion is studied using a multiple-image x-ray system. HMX-based PBX 9501 is used in this work, enabling direct comparison to recently-published data obtained with proton radiography [1]. Multiple x-ray images of the explosion are obtained with image spacing of ten microseconds or more. The explosion is simultaneously characterized with a high-speed camera using an interframe spacing of 11 mus. X-ray and camera images were both initiated passively by signals from an embedded thermocouple array, as opposed to being actively triggered by a laser pulse or other external source. X-ray images show an accelerating reacting frontmore » within the explosive, and also show unreacted explosive at the time the containment vessel bursts. High-speed camera images show debris ejected from the vessel expanding at 800-2100 m/s in the first tens of mus after the container wall failure. The effective center of the initiation volume is about 6 mm from the geometric center of the explosive.« less

  20. Using eye movements to investigate selective attention in chronic daily headache.

    PubMed

    Liossi, Christina; Schoth, Daniel E; Godwin, Hayward J; Liversedge, Simon P

    2014-03-01

    Previous research has demonstrated that chronic pain is associated with biased processing of pain-related information. Most studies have examined this bias by measuring response latencies. The present study extended previous work by recording eye movement behaviour in individuals with chronic headache and in healthy controls while participants viewed a set of images (i.e., facial expressions) from 4 emotion categories (pain, angry, happy, neutral). Biases in initial orienting were assessed from the location of the initial shift in gaze, and biases in the maintenance of attention were assessed from the duration of gaze on the picture that was initially fixated, and the mean number of visits, and mean fixation duration per image category. The eye movement behaviour of the participants in the chronic headache group was characterised by a bias in initial shift of orienting to pain. There was no evidence of individuals with chronic headache visiting more often, or spending significantly more time viewing, pain images compared to other images. Both participant groups showed a significantly greater bias to maintain gaze longer on happy images, relative to pain, angry, and neutral images. Results are consistent with a pain-related bias that operates in the orienting of attention on pain-related stimuli, and suggest that chronic pain participants' attentional biases for pain-related information are evident even when other emotional stimuli are present. Pain-related information-processing biases appear to be a robust feature of chronic pain and may have an important role in the maintenance of the disorder. Copyright © 2013 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  1. Fundus Photography as a Screening Method for Diabetic Retinopathy in Children With Type 1 Diabetes: Outcome of the Initial Photography.

    PubMed

    Gräsbeck, Thomas C; Gräsbeck, Sophia V; Miettinen, Päivi J; Summanen, Paula A

    2016-09-01

    To determine the success rate of the initial fundus photography session in producing gradable images for screening diabetic retinopathy in children <18 years of age with type 1 diabetes (T1D), and to analyze outcome-associated factors. Retrospective observational cohort study. Mydriatic red-free monochromatic 60-degree digital fundus images centered on the macula and optic disc of 213 patients were graded. Photography success was classified as "complete" if both images of both eyes were gradable, "partial" if both images of 1 eye were gradable, "macula-centered image(s) only" if only the macula-centered image of one or both eyes was gradable, and "unsuccessful" if neither macula-centered image was gradable. Complete success was reached in 97 (46%; 95% confidence interval [CI], 39-52) patients, at least partial success in 153 (72%; 95% CI, 65-78) patients, success of macula-centered image(s) only in 47 (22%; 95% CI, 17-28) patients, and in 13 (6%; 95%CI, 3-10) patients fundus photography was unsuccessful. Macula-centered images were more often gradable in both eyes than optic disc-centered images (P < .001). Success of photography did not differ between right and left eye. Sex, age at diagnosis of T1D, and the duration of diabetes, age, and glycemic control at the time of initial photography were unassociated with complete success. Partial success tended to decrease with increasing age category (P = .093), and the frequency of gradable macula-centered image(s) only increased with increasing age (P = .043). Less than half of the children achieved complete success, but in only 6% initial fundus photography was unsuccessful, indicating its value in assessing retinopathy in the pediatric setting. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Reconstruction of initial pressure from limited view photoacoustic images using deep learning

    NASA Astrophysics Data System (ADS)

    Waibel, Dominik; Gröhl, Janek; Isensee, Fabian; Kirchner, Thomas; Maier-Hein, Klaus; Maier-Hein, Lena

    2018-02-01

    Quantification of tissue properties with photoacoustic (PA) imaging typically requires a highly accurate representation of the initial pressure distribution in tissue. Almost all PA scanners reconstruct the PA image only from a partial scan of the emitted sound waves. Especially handheld devices, which have become increasingly popular due to their versatility and ease of use, only provide limited view data because of their geometry. Owing to such limitations in hardware as well as to the acoustic attenuation in tissue, state-of-the-art reconstruction methods deliver only approximations of the initial pressure distribution. To overcome the limited view problem, we present a machine learning-based approach to the reconstruction of initial pressure from limited view PA data. Our method involves a fully convolutional deep neural network based on a U-Net-like architecture with pixel-wise regression loss on the acquired PA images. It is trained and validated on in silico data generated with Monte Carlo simulations. In an initial study we found an increase in accuracy over the state-of-the-art when reconstructing simulated linear-array scans of blood vessels.

  3. Comparative Analysis of Reconstructed Image Quality in a Simulated Chromotomographic Imager

    DTIC Science & Technology

    2014-03-01

    quality . This example uses five basic images a backlit bar chart with random intensity, 100 nm separation. A total of 54 initial target...compared for a variety of scenes. Reconstructed image quality is highly dependent on the initial target hypercube so a total of 54 initial target...COMPARATIVE ANALYSIS OF RECONSTRUCTED IMAGE QUALITY IN A SIMULATED CHROMOTOMOGRAPHIC IMAGER THESIS

  4. Sex Differences in Working Memory after Mild Traumatic Brain Injury: A Functional MR Imaging Study.

    PubMed

    Hsu, Hui-Ling; Chen, David Yen-Ting; Tseng, Ying-Chi; Kuo, Ying-Sheng; Huang, Yen-Lin; Chiu, Wen-Ta; Yan, Feng-Xian; Wang, Wei-Shuan; Chen, Chi-Jen

    2015-09-01

    To evaluate sex differences in mild traumatic brain injury (MTBI) with working memory functional magnetic resonance (MR) imaging. Research ethics committee approval and patient written informed consent were obtained. Working memory brain activation patterns were assessed with functional MR imaging in 30 patients (15 consecutive men and 15 consecutive women) with MTBI and 30 control subjects (15 consecutive men and 15 consecutive women). Two imaging studies were performed in patients: the initial study, which was performed within 1 month after the injury, and a follow-up study, which was performed 6 weeks after the first study. For each participant, digit span and continuous performance testing were performed before functional MR imaging. Clinical data were analyzed by using Kruskal-Wallis, Mann-Whitney U, Wilcoxon signed rank, and Fisher exact tests. Within- and between-group differences of functional MR imaging data were analyzed with one- and two-sample t tests, respectively. Among female participants, the total digit span score was lower in the MTBI group than in the control group (P = .044). In initial working memory functional MR imaging studies, hyperactivation was found in the male MTBI group and hypoactivation was found in the female MTBI group compared with control male and female groups, respectively. At the 6-week follow-up study, the female MTBI group showed persistent hypoactivation, whereas the male MTBI group showed a regression of hyperactivation at visual comparison of activation maps. The male MTBI group was also found to have a higher initial ß value than the male control group (P = .040), and there was no significant difference between the male MTBI group and the male control group (P = .221) at follow-up evaluation, which was comparable to findings on activation maps. In the female MTBI group, average ß values at both initial and follow-up studies were lower compared with those in the female control group but were not statistically significant (P = .663 and P = .191, respectively). Female patients with MTBI had lower digit span scores than did female control subjects, and functional MR imaging depicted sex differences in working memory functional activation; hypoactivation with nonrecovery of activation change at follow-up studies may suggest a worse working memory outcome in female patients with MTBI.

  5. Automatic selection of landmarks in T1-weighted head MRI with regression forests for image registration initialization

    NASA Astrophysics Data System (ADS)

    Wang, Jianing; Liu, Yuan; Noble, Jack H.; Dawant, Benoit M.

    2017-02-01

    Medical image registration establishes a correspondence between images of biological structures and it is at the core of many applications. Commonly used deformable image registration methods are dependent on a good preregistration initialization. The initialization can be performed by localizing homologous landmarks and calculating a point-based transformation between the images. The selection of landmarks is however important. In this work, we present a learning-based method to automatically find a set of robust landmarks in 3D MR image volumes of the head to initialize non-rigid transformations. To validate our method, these selected landmarks are localized in unknown image volumes and they are used to compute a smoothing thin-plate splines transformation that registers the atlas to the volumes. The transformed atlas image is then used as the preregistration initialization of an intensity-based non-rigid registration algorithm. We show that the registration accuracy of this algorithm is statistically significantly improved when using the presented registration initialization over a standard intensity-based affine registration.

  6. Does body image influence the relationship between body weight and breastfeeding maintenance in new mothers?

    PubMed

    Swanson, Vivien; Keely, Alice; Denison, Fiona C

    2017-09-01

    Obese women have lower breastfeeding initiation and maintenance rates than healthy weight women. Research generally focuses on biomedical explanations for this. Psychosocial factors including body image and well-being after childbirth are less well understood as predictors of breastfeeding. In obese and healthy weight women, we investigated changes in body image between 72 hrs post-delivery and 6-8 weeks post-natal, studying how women's body image related to breastfeeding initiation and maintenance. We also investigated how psychological distress was related to body image. Longitudinal semi-structured questionnaire survey. Body image and psychological distress were assessed within 72 hrs of birth and by postal questionnaire at 6-8 weeks, for 70 obese and 70 healthy weight women initiating exclusive (breastmilk only) breastfeeding or mixed feeding (with formula milk) in hospital. Breastfeeding was re-assessed at 6-8 weeks. Obese women were less likely to exclusively breastfeed in hospital and maintain breastfeeding to 6-8 weeks. Better body image was related to maintaining breastfeeding and to lower post-natal psychological distress for all women, but education level was the most significant predictor of maintenance in multivariate regression including body image and weight status. Body image mediated, but did not moderate the relationship between weight and breastfeeding maintenance. Body image was lower overall in obese women, but all women had low body image satisfaction around childbirth, reducing further at 6-8 weeks. Health professionals should consider women's body image when discussing breastfeeding. A focus on breast function over form may support breastfeeding for all women. Statement of contribution What is already known on this subject? Obesity can negatively affect breastfeeding initiation and maintenance, but there is little information about how psychosocial factors affect this relationship. Body image may be an important factor, but has not been studied in relation to breastfeeding maintenance. What does this study add This article examines the influence of body image on obese and healthy-weight women's breastfeeding maintenance at 6-8 weeks. Different aspects of body image mediated but did not moderate the relationship between weight status and breastfeeding maintenance, but in multivariate regression, maternal education level was the most significant predictor. Obese women had poorer body image and were less likely to maintain breastfeeding; however, for all women, body image became more negative in this postpartum period. Interventions should normalize positive aspects of women's postnatal bodies, including function rather than form. Addressing body concerns could encourage new mothers to maintain breastfeeding, irrespective of weight status. © 2017 The British Psychological Society.

  7. The impact of diagnostic imaging wait times on the prognosis of lung cancer.

    PubMed

    Byrne, Suzanne C; Barrett, Brendan; Bhatia, Rick

    2015-02-01

    This study was performed to determine whether gaps in patient flow from initial lung imaging to computed tomography (CT) guided lung biopsy in patients with non-small cell lung cancer (NSCLC) was associated with a change in tumour size, stage, and thus prognosis. All patients who had a CT-guided lung biopsy in 2009 (phase I) and in 2011 (phase II) with a pathologic diagnosis of primary lung cancer (NSCLC) at Eastern Health, Newfoundland, were identified. Dates of initial abnormal imaging, confirmatory CT (if performed), and CT-guided biopsy were recorded, along with tumour size and resulting T stage at each time point. In 2010, wait times for diagnostic imaging at Eastern Health were reduced. The stage and prognosis of NSCLC in 2009 was compared with 2011. In phase 1, there was a statistically significant increase in tumour size (mean difference, 0.67 cm; P < .0001) and stage (P < .0001) from initial image to biopsy. There was a moderate correlation between the time (in days) between the images and change in size (r = 0.33, P = .008) or stage (r = 0.26, P = .036). In phase II, the median wait time from initial imaging to confirmatory CT was reduced to 7.5 days (from 19 days). At this reduced wait time, there was no statistically significant increase in tumour size (mean difference, 0.02; P > .05) or stage (P > .05) from initial imaging to confirmatory CT. Delays in patient flow through diagnostic imaging resulted in an increase in tumour size and stage, with a negative impact on prognosis of NSCLC. This information contributed to the hiring of additional CT technologists and extended CT hours to decrease the wait time for diagnostic imaging. With reduced wait times, the prognosis of NSCLC was not adversely impacted as patients navigated through diagnostic imaging. Copyright © 2015 Canadian Association of Radiologists. All rights reserved.

  8. Response of the Pre-Oriented Goal-Directed Attention to Usual and Unusual Distractors: A Preliminary Study

    PubMed Central

    Baghdadi, Golnaz; Towhidkhah, Farzad; Rostami, Reza; Raza, Mohsen

    2017-01-01

    Introduction: In this study, we investigated the distraction power of the unusual and usual images on the attention of 20 healthy primary school children. Methods: Our study was different from previous ones in that the participants were asked to fix the initial position of their attention on a predefined location after being presented with unusual images as distractors. The goals were presented in locations, which were far from the attraction basin of distractors. We expected that the pre-orienting of the attention to the position of targets would reduce the attractive effect of unusual images compared to the usual ones. The percentage of correct responses and the reaction time were measured as behavioral indicators of attention performance. Results: Results showed that using the goal-directed attention, subjects ignored both kinds of distractors nearly the same way. Conclusion: With regard to previous reports about more attraction towards the unusual images, it is suggested that the dynamics of the visual attention system be sensitive to the initial condition. That is, changing the initial position of the attention can lead to the decrement of the unusual images effects. However, several other possibilities such as a probable delay in processing unusual features could explain this observation, too. PMID:28540000

  9. Reflectance confocal microscopy-guided laser ablation of basal cell carcinomas: initial in vivo results

    NASA Astrophysics Data System (ADS)

    Sierra, Heidy; Cordova, Miguel; Yelamos, Oriol; Chen, Chih-Shan Jason; Rajadhyaksha, Milind

    2017-02-01

    Laser ablation offers a procedure for precise, fast and minimally invasive removal of superficial and early nodular basal cell carcinomas (BCCs). However, the lack of histopathological confirmation has been a limitation toward widespread use in the clinic. A reflectance confocal microscopy (RCM) imaging-guided laser ablation approach offers cellular-level histopathology-like feedback directly on the patient, which may guide and help improve the efficacy of this procedure. We performed an initial study on 44 BCCs on 21 patients in vivo (based in an ex vivo bench-top study reported in our earlier papers), using a pulsed erbium: ytterbium aluminum garnet laser and a contrast agent (aluminum chloride). Initial 10 lesions, the RCM imaging-guided detection of either presence of residual tumor or complete clearance was immediately confirmed with histopathology. Additionally, 34 BCCs on 15 patients were treated with RCM imaging-guided laser ablation, and the clearance of tumor is currently being monitored with follow-up imaging (i. e., no histopathology) at 3, 6 and 18 months. Thus far, the imaging resolution appears to be sufficient and consistent for monitoring efficacy in the wound, both immediately post-ablation and subsequently during recovery. The efficacy appears to be promising. However, further investigation and optimization to image over the entire wound (without missing any areas) need to be investigated.

  10. Iterative image reconstruction in elastic inhomogenous media with application to transcranial photoacoustic tomography

    NASA Astrophysics Data System (ADS)

    Poudel, Joemini; Matthews, Thomas P.; Mitsuhashi, Kenji; Garcia-Uribe, Alejandro; Wang, Lihong V.; Anastasio, Mark A.

    2017-03-01

    Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the photoacoustically induced initial pressure distribution within tissue. The PACT reconstruction problem corresponds to a time-domain inverse source problem, where the initial pressure distribution is recovered from the measurements recorded on an aperture outside the support of the source. A major challenge in transcranial PACT brain imaging is to compensate for aberrations in the measured data due to the propagation of the photoacoustic wavefields through the skull. To properly account for these effects, a wave equation-based inversion method should be employed that can model the heterogeneous elastic properties of the medium. In this study, an iterative image reconstruction method for 3D transcranial PACT is developed based on the elastic wave equation. To accomplish this, a forward model based on a finite-difference time-domain discretization of the elastic wave equation is established. Subsequently, gradient-based methods are employed for computing penalized least squares estimates of the initial source distribution that produced the measured photoacoustic data. The developed reconstruction algorithm is validated and investigated through computer-simulation studies.

  11. Imaging initial formation processes of nanobubbles at the graphite-water interface through high-speed atomic force microscopy

    NASA Astrophysics Data System (ADS)

    Liao, Hsien-Shun; Yang, Chih-Wen; Ko, Hsien-Chen; Hwu, En-Te; Hwang, Ing-Shouh

    2018-03-01

    The initial formation process of nanobubbles at solid-water interfaces remains unclear because of the limitations of current imaging techniques. To directly observe the formation process, an astigmatic high-speed atomic force microscope (AFM) was modified to enable imaging in the liquid environment. By using a customized cantilever holder, the resonance of small cantilevers was effectively enhanced in water. The proposed high-speed imaging technique yielded highly dynamic quasi-two-dimensional (2D) gas structures (thickness: 20-30 nm) initially at the graphite-water interface. The 2D structures were laterally mobile mainly within certain areas, but occasionally a gas structure might extensively migrate and settle in a new area. The 2D structures were often confined by substrate step edges in one lateral dimension. Eventually, all quasi-2D gas structures were transformed into cap-shaped nanobubbles of higher heights and reduced lateral dimensions. These nanobubbles were immobile and remained stable under continuous AFM imaging. This study demonstrated that nanobubbles could be stably imaged at a scan rate of 100 lines per second (640 μm/s).

  12. Time-sequenced X-ray Observation of a Thermal Explosion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tringe, J W; Molitoris, J D; Smilowitz, L

    The evolution of a thermally-initiated explosion is studied using a multiple-image x-ray system. HMX-based PBX 9501 is used in this work, enabling direct comparison to recently-published data obtained with proton radiography [1]. Multiple x-ray images of the explosion are obtained with image spacing of ten microseconds or more. The explosion is simultaneously characterized with a high-speed camera using an interframe spacing of 11 {micro}s. X-ray and camera images were both initiated passively by signals from an embedded thermocouple array, as opposed to being actively triggered by a laser pulse or other external source. X-ray images show an accelerating reacting frontmore » within the explosive, and also show unreacted explosive at the time the containment vessel bursts. High-speed camera images show debris ejected from the vessel expanding at 800-2100 m/s in the first tens of {micro}s after the container wall failure. The effective center of the initiation volume is about 6 mm from the geometric center of the explosive.« less

  13. Imaging of high-amylose starch tablets. 3. Initial diffusion and temperature effects.

    PubMed

    Thérien-Aubin, Héloïse; Baille, Wilms E; Zhu, Xiao Xia; Marchessault, Robert H

    2005-01-01

    The penetration of water into cross-linked high amylose starch tablets was studied at different temperatures by nuclear magnetic resonance (NMR) imaging, which follows the changes occurring at the surface and inside the starch tablets during swelling. It was found that the swelling was anisotropic, whereas water diffusion was almost isotropic. The water proton image profiles at the initial stage of water penetration were used to calculate the initial diffusion coefficient. The swelling and water concentration gradients in this controlled release system show significant temperature dependence. Diffusion behavior changed from Fickian to Case II diffusion with increasing temperature. The observed phenomena are attributed to the gelatinization of starch and the pseudo-cross-linking effect of double helix formation.

  14. Health economic assessment of Gd-EOB-DTPA MRI versus ECCM-MRI and multi-detector CT for diagnosis of hepatocellular carcinoma in China

    PubMed Central

    He, Xiaoning; Holtorf, Anke-Peggy; Rinde, Harald; Xie, Shuangshuang; Shen, Wen; Hou, Jiancun; Li, Xuehua; Li, Ziping; Lai, Jiaming; Wang, Yuting; Zhang, Lin; Wang, Jian; Li, Xuesong; Ma, Kuansheng; Ye, Feng; Ouyang, Han; Zhao, Hong

    2018-01-01

    Limited data exists in China on the comparative cost of gadolinium ethoxybenzyl diethylenetriamine magnetic resonance imaging (Gd-EOB-DTPA-MRI) with other imaging techniques. This study compared the total cost of Gd-EOB-DTPA-MRI with multidetector computed tomography (MDCT) and extracellular contrast media–enhanced MRI (ECCM-MRI) as initial imaging procedures in patients with suspected hepatocellular carcinoma (HCC). We developed a decision-tree model on the basis of the Chinese clinical guidelines for HCC, which was validated by clinical experts from China. The model compared the diagnostic accuracy and costs of alternative initial imaging procedures. Compared with MDCT and ECCM-MRI, Gd-EOB-DTPA-MRI imaging was associated with higher rates of diagnostic accuracy, i.e. higher proportions of true positives (TP) and true negatives (TN) with lower false positives (FP). Total diagnosis and treatment cost per patient after the initial Gd-EOB-DTPA-MRI evaluation was similar to MDCT (¥30,360 vs. ¥30,803) and lower than that reported with ECCM-MRI (¥30,360 vs. ¥31,465). Lower treatment cost after initial Gd-EOB-DTPA-MRI was driven by reduced utilization of confirmatory diagnostic procedures and unnecessary treatments. The findings reported that Gd-EOB-DTPA-MRI offered higher diagnostic accuracy compared with MDCT and ECCM-MRI at a comparable cost, which indicates Gd-EOB-DTPA-MRI could be the preferred initial imaging procedure for the diagnosis of HCC in China. PMID:29324837

  15. The assessment of mucosal surgical margins in head and neck cancer surgery with narrow band imaging.

    PubMed

    Šifrer, Robert; Urbančič, Jure; Strojan, Primož; Aničin, Aleksandar; Žargi, Miha

    2017-07-01

    The diagnostic gain of narrow band imaging in the definition of surgical margins in the treatment of head and neck cancer was evaluated. A prospective study, blinded to the pathologist, with historical comparison. The study group included 45 patients subjected to the intraoperative definition of margins by narrow band imaging. The control group included 55 patients who had undergone standard definition of margins. All patients underwent resection of the tumor and frozen section analysis of superficial margins. The rate of initial R 0 resection and the ratio of histologically negative margins for both groups were statistically compared. The rate of initial R 0 resection in the study group and in the control group was 88.9% and 70.9% (P = .047), and the ratio of histologically negative margins was 95.9% and 88.4% (P = .017), respectively. Narrow band imaging reveals a microscopic extension of the tumor that could be effectively used to better define superficial margins and to achieve a higher rate of initial R 0 resections. 4 Laryngoscope, 127:1577-1582, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  16. Multishot Targeted PROPELLER Magnetic Resonance Imaging: Description of the Technique and Initial Applications

    PubMed Central

    Deng, Jie; Larson, Andrew C.

    2010-01-01

    Objectives To test the feasibility of combining inner-volume imaging (IVI) techniques with conventional multishot periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) techniques for targeted-PROPELLER magnetic resonance imaging. Materials and Methods Perpendicular section-selective gradients for spatially selective excitation and refocusing RF pulses were applied to limit the refocused field-of-view (FOV) along the phase-encoding direction for each rectangular blade image. We performed comparison studies in phantoms and normal volunteers by using targeted-PROPELLER methods for a wide range of imaging applications that commonly use turbo-spin-echo (TSE) approaches (brain, abdominal, vessel wall, cardiac). Results In these initial studies, we demonstrated the feasibility of using targeted-PROPELLER approaches to limit the imaging FOV thereby reducing the number of blades or permitting increased spatial resolution without commensurate increases in scan time. Both phantom and in vivo motion studies demonstrated the potential for more robust regional self-navigated motion correction compared with conventional full FOV PROPELLER methods. Conclusion We demonstrated that the reduced FOV targeted-PROPELLER technique offers the potential for reducing imaging time, increasing spatial resolution, and targeting specific areas for robust regional motion correction. PMID:19465860

  17. Toward Imaging of Small Objects with XUV Radiation

    NASA Astrophysics Data System (ADS)

    Sayrac, Muhammed; Kolomenski, Alexandre A.; Boran, Yakup; Schuessler, Hans

    The coherent diffraction imaging (CDI) technique has the potential to capture high resolution images of nano- or micron-sized structures when using XUV radiation obtained by high harmonic radiation (HHG) process. When a small object is exposed to XUV radiation, a diffraction pattern of the object is created. The advances in the coherent HHG enable obtaining photon flux sufficient for XUV imaging. The diffractive imaging technique from coherent table top XUV beams have made possible nanometer-scale resolution imaging by replacing the imaging optics with a computer reconstruction algorithm. In this study, we present our initial work on diffractive imaging using a tabletop XUV source. The initial investigation of imaging of a micron-sized mesh with an optimized HHG source is demonstrated. This work was supported in part by the Robert A. Welch Foundation Grant No. A1546 and the Qatar Foundation under the grant NPRP 8-735-1-154. M. Sayrac acknowledges support from the Ministry of National Education of the Republic of Turkey.

  18. High speed imaging for assessment of impact damage in natural fibre biocomposites

    NASA Astrophysics Data System (ADS)

    Ramakrishnan, Karthik Ram; Corn, Stephane; Le Moigne, Nicolas; Ienny, Patrick; Leger, Romain; Slangen, Pierre R.

    2017-06-01

    The use of Digital Image Correlation has been generally limited to the estimation of mechanical properties and fracture behaviour at low to moderate strain rates. High speed cameras dedicated to ballistic testing are often used to measure the initial and residual velocities of the projectile but rarely for damage assessment. The evaluation of impact damage is frequently achieved post-impact using visual inspection, ultrasonic C-scan or other NDI methods. Ultra-high speed cameras and developments in image processing have made possible the measurement of surface deformations and stresses in real time during dynamic cracking. In this paper, a method is presented to correlate the force- displacement data from the sensors to the slow motion tracking of the transient failure cracks using real-time high speed imaging. Natural fibre reinforced composites made of flax fibres and polypropylene matrix was chosen for the study. The creation of macro-cracks during the impact results in the loss of stiffness and a corresponding drop in the force history. However, optical instrumentation shows that the initiation of damage is not always evident and so the assessment of damage requires the use of a local approach. Digital Image Correlation is used to study the strain history of the composite and to identify the initiation and progression of damage. The effect of fly-speckled texture on strain measurement by image correlation is also studied. The developed method can be used for the evaluation of impact damage for different composite materials.

  19. Early Rivaroxaban Use After Cardioembolic Stroke May Not Result in Hemorrhagic Transformation: A Prospective Magnetic Resonance Imaging Study.

    PubMed

    Gioia, Laura C; Kate, Mahesh; Sivakumar, Leka; Hussain, Dulara; Kalashyan, Hayrapet; Buck, Brian; Bussiere, Miguel; Jeerakathil, Thomas; Shuaib, Ashfaq; Emery, Derek; Butcher, Ken

    2016-07-01

    Early anticoagulation after cardioembolic stroke remains controversial because of the potential for hemorrhagic transformation (HT). We tested the safety and feasibility of initiating rivaroxaban ≤14 days after cardioembolic stroke/transient ischemic attack. A prospective, open-label study of patients with atrial fibrillation treated with rivaroxaban ≤14 days of transient ischemic attack or ischemic stroke (National Institute of Health Stroke Scale <9). All patients underwent magnetic resonance imaging <24 hours of rivaroxaban initiation and day 7. The primary end point was symptomatic HT at day 7. Sixty patients (mean±SD age 71±19 years, 82% stroke/18% transient ischemic attack) were enrolled. Median (interquartile range) time from onset to rivaroxaban was 3 (5) days. At treatment initiation, median National Institute of Health Stroke Scale was 2 (4), and median diffusion-weighted imaging volume was 7.9 (13.7) mL. At baseline, HT was present in 25 (42%) patients (hemorrhagic infarct [HI]1=19, HI2=6). On follow-up magnetic resonance imaging, no patients developed symptomatic HT. New asymptomatic HI1 developed in 3 patients, and asymptomatic progression from HI1 to HI2 occurred in 5 patients; otherwise, HT remained unchanged at day 7. These data support the safety of rivaroxaban initiation ≤14 days of mild-moderate cardioembolic stroke/transient ischemic attack. Magnetic resonance imaging evidence of petechial HT, which is common, does not appear to increase the risk of symptomatic HT. © 2016 American Heart Association, Inc.

  20. Automatic selection of landmarks in T1-weighted head MRI with regression forests for image registration initialization.

    PubMed

    Wang, Jianing; Liu, Yuan; Noble, Jack H; Dawant, Benoit M

    2017-10-01

    Medical image registration establishes a correspondence between images of biological structures, and it is at the core of many applications. Commonly used deformable image registration methods depend on a good preregistration initialization. We develop a learning-based method to automatically find a set of robust landmarks in three-dimensional MR image volumes of the head. These landmarks are then used to compute a thin plate spline-based initialization transformation. The process involves two steps: (1) identifying a set of landmarks that can be reliably localized in the images and (2) selecting among them the subset that leads to a good initial transformation. To validate our method, we use it to initialize five well-established deformable registration algorithms that are subsequently used to register an atlas to MR images of the head. We compare our proposed initialization method with a standard approach that involves estimating an affine transformation with an intensity-based approach. We show that for all five registration algorithms the final registration results are statistically better when they are initialized with the method that we propose than when a standard approach is used. The technique that we propose is generic and could be used to initialize nonrigid registration algorithms for other applications.

  1. Smart grid initialization reduces the computational complexity of multi-objective image registration based on a dual-dynamic transformation model to account for large anatomical differences

    NASA Astrophysics Data System (ADS)

    Bosman, Peter A. N.; Alderliesten, Tanja

    2016-03-01

    We recently demonstrated the strong potential of using dual-dynamic transformation models when tackling deformable image registration problems involving large anatomical differences. Dual-dynamic transformation models employ two moving grids instead of the common single moving grid for the target image (and single fixed grid for the source image). We previously employed powerful optimization algorithms to make use of the additional flexibility offered by a dual-dynamic transformation model with good results, directly obtaining insight into the trade-off between important registration objectives as a result of taking a multi-objective approach to optimization. However, optimization has so far been initialized using two regular grids, which still leaves a great potential of dual-dynamic transformation models untapped: a-priori grid alignment with image structures/areas that are expected to deform more. This allows (far) less grid points to be used, compared to using a sufficiently refined regular grid, leading to (far) more efficient optimization, or, equivalently, more accurate results using the same number of grid points. We study the implications of exploiting this potential by experimenting with two new smart grid initialization procedures: one manual expert-based and one automated image-feature-based. We consider a CT test case with large differences in bladder volume with and without a multi-resolution scheme and find a substantial benefit of using smart grid initialization.

  2. Novel Diffusion-Weighted MRI for High-Grade Prostate Cancer Detection

    DTIC Science & Technology

    2016-10-01

    in image resolution and scale.This process is critical for evaluating new imaging modalities.Our initial findings illustrate the potential of the...eligible for analysis as determined by adequate pathologic processing and MR images deemed to be of adequate quality by the study team.  The...histology samples have been requested from the UIC biorepository for digitization  All MR images have been collected and prepared for image processing

  3. Improving Brain Magnetic Resonance Image (MRI) Segmentation via a Novel Algorithm based on Genetic and Regional Growth

    PubMed Central

    A., Javadpour; A., Mohammadi

    2016-01-01

    Background Regarding the importance of right diagnosis in medical applications, various methods have been exploited for processing medical images solar. The method of segmentation is used to analyze anal to miscall structures in medical imaging. Objective This study describes a new method for brain Magnetic Resonance Image (MRI) segmentation via a novel algorithm based on genetic and regional growth. Methods Among medical imaging methods, brains MRI segmentation is important due to high contrast of non-intrusive soft tissue and high spatial resolution. Size variations of brain tissues are often accompanied by various diseases such as Alzheimer’s disease. As our knowledge about the relation between various brain diseases and deviation of brain anatomy increases, MRI segmentation is exploited as the first step in early diagnosis. In this paper, regional growth method and auto-mate selection of initial points by genetic algorithm is used to introduce a new method for MRI segmentation. Primary pixels and similarity criterion are automatically by genetic algorithms to maximize the accuracy and validity in image segmentation. Results By using genetic algorithms and defining the fixed function of image segmentation, the initial points for the algorithm were found. The proposed algorithms are applied to the images and results are manually selected by regional growth in which the initial points were compared. The results showed that the proposed algorithm could reduce segmentation error effectively. Conclusion The study concluded that the proposed algorithm could reduce segmentation error effectively and help us to diagnose brain diseases. PMID:27672629

  4. Changing job seekers' image perceptions during recruitment visits: the moderating role of belief confidence.

    PubMed

    Slaughter, Jerel E; Cable, Daniel M; Turban, Daniel B

    2014-11-01

    The purpose of this study was to understand how an important construct in social psychology-confidence in one's beliefs-could both (a) influence the effectiveness of organizations' recruiting processes and (b) be changed during recruitment. Using a sample of recruits to a branch of the United States military, the authors studied belief confidence before and after recruits' formal visits to the organization's recruiting stations. Personal sources of information had a stronger influence on recruits' belief confidence than impersonal sources. Moreover, recruits' confidence in their initial beliefs affected how perceptions of the recruiter changed their employer images. Among participants with low-initial confidence, the relation between recruitment experiences and employer images was positive and linear across the whole range of recruitment experiences. Among recruits with high-initial confidence, however, the recruitment experience-image relationship was curvilinear, such that recruitment experiences were related to images only at more positive recruitment experiences. The relationship between recruitment experiences and changes in belief confidence was also curvilinear, such that only more positive recruitment experiences led to changes in confidence. These results indicate not only that belief confidence influences the effectiveness of recruiting efforts but also that recruiting efforts can influence belief confidence. (PsycINFO Database Record (c) 2014 APA, all rights reserved).

  5. Predicting High Imaging Utilization Based on Initial Radiology Reports: A Feasibility Study of Machine Learning.

    PubMed

    Hassanpour, Saeed; Langlotz, Curtis P

    2016-01-01

    Imaging utilization has significantly increased over the last two decades, and is only recently showing signs of moderating. To help healthcare providers identify patients at risk for high imaging utilization, we developed a prediction model to recognize high imaging utilizers based on their initial imaging reports. The prediction model uses a machine learning text classification framework. In this study, we used radiology reports from 18,384 patients with at least one abdomen computed tomography study in their imaging record at Stanford Health Care as the training set. We modeled the radiology reports in a vector space and trained a support vector machine classifier for this prediction task. We evaluated our model on a separate test set of 4791 patients. In addition to high prediction accuracy, in our method, we aimed at achieving high specificity to identify patients at high risk for high imaging utilization. Our results (accuracy: 94.0%, sensitivity: 74.4%, specificity: 97.9%, positive predictive value: 87.3%, negative predictive value: 95.1%) show that a prediction model can enable healthcare providers to identify in advance patients who are likely to be high utilizers of imaging services. Machine learning classifiers developed from narrative radiology reports are feasible methods to predict imaging utilization. Such systems can be used to identify high utilizers, inform future image ordering behavior, and encourage judicious use of imaging. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  6. Effect of clinical decision rules, patient cost and malpractice information on clinician brain CT image ordering: a randomized controlled trial.

    PubMed

    Gimbel, Ronald W; Pirrallo, Ronald G; Lowe, Steven C; Wright, David W; Zhang, Lu; Woo, Min-Jae; Fontelo, Paul; Liu, Fang; Connor, Zachary

    2018-03-12

    The frequency of head computed tomography (CT) imaging for mild head trauma patients has raised safety and cost concerns. Validated clinical decision rules exist in the published literature and on-line sources to guide medical image ordering but are often not used by emergency department (ED) clinicians. Using simulation, we explored whether the presentation of a clinical decision rule (i.e. Canadian CT Head Rule - CCHR), findings from malpractice cases related to clinicians not ordering CT imaging in mild head trauma cases, and estimated patient out-of-pocket cost might influence clinician brain CT ordering. Understanding what type and how information may influence clinical decision making in the ordering advanced medical imaging is important in shaping the optimal design and implementation of related clinical decision support systems. Multi-center, double-blinded simulation-based randomized controlled trial. Following standardized clinical vignette presentation, clinicians made an initial imaging decision for the patient. This was followed by additional information on decision support rules, malpractice outcome review, and patient cost; each with opportunity to modify their initial order. The malpractice and cost information differed by assigned group to test the any temporal relationship. The simulation closed with a second vignette and an imaging decision. One hundred sixteen of the 167 participants (66.9%) initially ordered a brain CT scan. After CCHR presentation, the number of clinicians ordering a CT dropped to 76 (45.8%), representing a 21.1% reduction in CT ordering (P = 0.002). This reduction in CT ordering was maintained, in comparison to initial imaging orders, when presented with malpractice review information (p = 0.002) and patient cost information (p = 0.002). About 57% of clinicians changed their order during study, while 43% never modified their imaging order. This study suggests that ED clinician brain CT imaging decisions may be influenced by clinical decision support rules, patient out-of-pocket cost information and findings from malpractice case review. NCT03449862 , February 27, 2018, Retrospectively registered.

  7. [Comparison of initial and delayed myocardial imaging with beta-methyl-p-[123I]-iodophenylpentadecanoic acid in acute myocardial infarction].

    PubMed

    Naruse, H; Yoshimura, N; Yamamoto, J; Morita, M; Fukutake, N; Ohyanagi, M; Iwasaki, T; Fukuchi, M

    1994-01-01

    Myocardial imaging using beta-methyl-p-[123I]-iodophenylpentadecanoic acid (BMIPP) of 15 patients with acute myocardial infarction was performed to assess "fill-in" and "washout" defects in the delayed myocardial image. The initial and delayed images were evaluated by a visual and quantitative washout rate method. Visual judgement found 8/180 (4%) segments showed "fill-in" defects, and 24/180 segments (13%) showed "washout" defects. There was no relationship between days from onset to the study and the frequency of fill-in and washout defects. The mean washout rate in the segments with "fill-in" defects was 9.0 +/- 16.6%, and that of "washout" defects was 24.9 +/- 18.1% which was significantly higher than in controls (8.7 +/- 15.4%, p < 0.05). There was no correlation between mean washout rate and total blood lipids, total cholesterol, triglyceride and HDL-cholesterol. Therefore, neither time from onset nor blood lipids level was related to changes from the initial image to the delayed image. These changes may be due to relative (false) findings due to changes in circumference, and may be based on myocardial characteristics after myocardial infarction and/or reperfusion.

  8. Eye vergence responses during a visual memory task.

    PubMed

    Solé Puig, Maria; Romeo, August; Cañete Crespillo, Jose; Supèr, Hans

    2017-02-08

    In a previous report it was shown that covertly attending visual stimuli produce small convergence of the eyes, and that visual stimuli can give rise to different modulations of the angle of eye vergence, depending on their power to capture attention. Working memory is highly dependent on attention. Therefore, in this study we assessed vergence responses in a memory task. Participants scanned a set of 8 or 12 images for 10 s, and thereafter were presented with a series of single images. One half were repeat images - that is, they belonged to the initial set - and the other half were novel images. Participants were asked to indicate whether or not the images were included in the initial image set. We observed that eyes converge during scanning the set of images and during the presentation of the single images. The convergence was stronger for remembered images compared with the vergence for nonremembered images. Modulation in pupil size did not correspond to behavioural responses. The correspondence between vergence and coding/retrieval processes of memory strengthen the idea of a role for vergence in attention processing of visual information.

  9. Piloted studies of Enhanced or Synthetic Vision display parameters

    NASA Technical Reports Server (NTRS)

    Harris, Randall L., Sr.; Parrish, Russell V.

    1992-01-01

    This paper summarizes the results of several studies conducted at Langley Research Center over the past few years. The purposes of these studies were to investigate parameters of pictorial displays and imaging sensors that affect pilot approach and landing performance. Pictorial displays have demonstrated exceptional tracking performance and improved the pilots' spatial awareness. Stereopsis cueing improved pilot flight performance and reduced pilot stress. Sensor image parameters such as increased field-of-view. faster image update rate, and aiding symbology improved flare initiation. Finer image resolution and magnification improved attitude control performance parameters.

  10. Alzheimer’s Disease Neuroimaging Initiative biomarkers as quantitative phenotypes: Genetics core aims, progress, and plans

    PubMed Central

    Saykin, Andrew J.; Shen, Li; Foroud, Tatiana M.; Potkin, Steven G.; Swaminathan, Shanker; Kim, Sungeun; Risacher, Shannon L.; Nho, Kwangsik; Huentelman, Matthew J.; Craig, David W.; Thompson, Paul M.; Stein, Jason L.; Moore, Jason H.; Farrer, Lindsay A.; Green, Robert C.; Bertram, Lars; Jack, Clifford R.; Weiner, Michael W.

    2010-01-01

    The role of the Alzheimer’s Disease Neuroimaging Initiative Genetics Core is to facilitate the investigation of genetic influences on disease onset and trajectory as reflected in structural, functional, and molecular imaging changes; fluid biomarkers; and cognitive status. Major goals include (1) blood sample processing, genotyping, and dissemination, (2) genome-wide association studies (GWAS) of longitudinal phenotypic data, and (3) providing a central resource, point of contact and planning group for genetics within Alzheimer’s Disease Neuroimaging Initiative. Genome-wide array data have been publicly released and updated, and several neuroimaging GWAS have recently been reported examining baseline magnetic resonance imaging measures as quantitative phenotypes. Other preliminary investigations include copy number variation in mild cognitive impairment and Alzheimer’s disease and GWAS of baseline cerebrospinal fluid biomarkers and longitudinal changes on magnetic resonance imaging. Blood collection for RNA studies is a new direction. Genetic studies of longitudinal phenotypes hold promise for elucidating disease mechanisms and risk, development of therapeutic strategies, and refining selection criteria for clinical trials. PMID:20451875

  11. Magnetic resonance imaging and image analysis for assessment of HPMC matrix tablets structural evolution in USP Apparatus 4.

    PubMed

    Kulinowski, Piotr; Dorożyński, Przemysław; Młynarczyk, Anna; Węglarz, Władysław P

    2011-05-01

    The purpose of the study was to present a methodology for the processing of Magnetic Resonance Imaging (MRI) data for the quantification of the dosage form matrix evolution during drug dissolution. The results of the study were verified by comparison with other approaches presented in literature. A commercially available, HPMC-based quetiapine fumarate tablet was studied with a 4.7T MR system. Imaging was performed inside an MRI probe-head coupled with a flow-through cell for 12 h in circulating water. The images were segmented into three regions using threshold-based segmentation algorithms due to trimodal structure of the image intensity histograms. Temporal evolution of dry glassy, swollen glassy and gel regions was monitored. The characteristic features were observed: initial high expansion rate of the swollen glassy and gel layers due to initial water uptake, dry glassy core disappearance and maximum area of swollen glassy region at 4 h, and subsequent gel layer thickness increase at the expense of swollen glassy layer. The temporal evolution of an HPMC-based tablet by means of noninvasive MRI integrated with USP Apparatus 4 was found to be consistent with both the theoretical model based on polymer disentanglement concentration and experimental VIS/FTIR studies.

  12. Potential costs of breast augmentation mammaplasty.

    PubMed

    Schmitt, William P; Eichhorn, Mitchell G; Ford, Ronald D

    2016-01-01

    Augmentation mammaplasty is one of the most common surgical procedures performed by plastic surgeons. The aim of this study was to estimate the cost of the initial procedure and its subsequent complications, as well as project the cost of Food and Drug Administration (FDA)-recommended surveillance imaging. The potential costs to the individual patient and society were calculated. Local plastic surgeons provided billing data for the initial primary silicone augmentation and reoperative procedures. Complication rates used for the cost analysis were obtained from the Allergen Core study on silicone implants. Imaging surveillance costs were considered in the estimations. The average baseline initial cost of silicone augmentation mammaplasty was calculated at $6335. The average total cost of primary breast augmentation over the first decade for an individual patient, including complications requiring reoperation and other ancillary costs, was calculated at $8226. Each decade thereafter cost an additional $1891. Costs may exceed $15,000 over an averaged lifetime, and the recommended implant surveillance could cost an additional $33,750. The potential cost of a breast augmentation, which includes the costs of complications and imaging, is significantly higher than the initial cost of the procedure. Level III, economic and decision analysis study. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Guided filter-based fusion method for multiexposure images

    NASA Astrophysics Data System (ADS)

    Hou, Xinglin; Luo, Haibo; Qi, Feng; Zhou, Peipei

    2016-11-01

    It is challenging to capture a high-dynamic range (HDR) scene using a low-dynamic range camera. A weighted sum-based image fusion (IF) algorithm is proposed so as to express an HDR scene with a high-quality image. This method mainly includes three parts. First, two image features, i.e., gradients and well-exposedness are measured to estimate the initial weight maps. Second, the initial weight maps are refined by a guided filter, in which the source image is considered as the guidance image. This process could reduce the noise in initial weight maps and preserve more texture consistent with the original images. Finally, the fused image is constructed by a weighted sum of source images in the spatial domain. The main contributions of this method are the estimation of the initial weight maps and the appropriate use of the guided filter-based weight maps refinement. It provides accurate weight maps for IF. Compared to traditional IF methods, this algorithm avoids image segmentation, combination, and the camera response curve calibration. Furthermore, experimental results demonstrate the superiority of the proposed method in both subjective and objective evaluations.

  14. ACTIM: an EDA initiated study on spectral active imaging

    NASA Astrophysics Data System (ADS)

    Steinvall, O.; Renhorn, I.; Ahlberg, J.; Larsson, H.; Letalick, D.; Repasi, E.; Lutzmann, P.; Anstett, G.; Hamoir, D.; Hespel, L.; Boucher, Y.

    2010-10-01

    This paper will describe ongoing work from an EDA initiated study on Active Imaging with emphasis of using multi or broadband spectral lasers and receivers. Present laser based imaging and mapping systems are mostly based on a fixed frequency lasers. On the other hand great progress has recently occurred in passive multi- and hyperspectral imaging with applications ranging from environmental monitoring and geology to mapping, military surveillance, and reconnaissance. Data bases on spectral signatures allow the possibility to discriminate between different materials in the scene. Present multi- and hyperspectral sensors mainly operate in the visible and short wavelength region (0.4-2.5 μm) and rely on the solar radiation giving shortcoming due to shadows, clouds, illumination angles and lack of night operation. Active spectral imaging however will largely overcome these difficulties by a complete control of the illumination. Active illumination enables spectral night and low-light operation beside a robust way of obtaining polarization and high resolution 2D/3D information. Recent development of broadband lasers and advanced imaging 3D focal plane arrays has led to new opportunities for advanced spectral and polarization imaging with high range resolution. Fusing the knowledge of ladar and passive spectral imaging will result in new capabilities in the field of EO-sensing to be shown in the study. We will present an overview of technology, systems and applications for active spectral imaging and propose future activities in connection with some prioritized applications.

  15. An initial report on the intraoperative use of indocyanine green fluorescence imaging in the surgical management of liver tumorss.

    PubMed

    Takahashi, Hideo; Zaidi, Nisar; Berber, Eren

    2016-10-01

    There has been a recent interest in the use of Indocyanine green (ICG) imaging. The aim of this study is to review our initial experience in liver surgery. ICG fluorescent imaging was used in 15 patients undergoing surgical treatment of their liver tumors between 2015 and 2016. ICG imaging was initially performed, followed by intraoperative ultrasound (IOUS). Findings on fluorescence were compared with preoperative cross-sectional imaging and IOUS. Sixty-two lesions were identified, with 34 located superficially and 28 deeply in the liver. While 13 patients underwent surgery for malignant liver metastases, two patients had operations for benign liver diseases. Seven patients underwent open or robotic liver resections, five laparoscopic microwave liver ablation, and three diagnostic laparoscopy. ICG identified all of the superficial lesions. IOUS identified 98% of all lesions. The most benefit of ICG was in showing the margins of the superficial lesions in real-time and guiding surgical treatment, which was limited by IOUS. This is the first North American study to evaluate the potential utility of ICG during liver surgery. Its major benefit seems to be in providing real-time feedback to the surgeon about the margins of superficial tumors for resection or ablation. J. Surg. Oncol. 2016;114:625-629. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  16. X-ray imaging and 3D reconstruction of in-flight exploding foil initiator flyers

    DOE PAGES

    Willey, T. M.; Champley, K.; Hodgin, R.; ...

    2016-06-17

    Exploding foil initiators (EFIs), also known as slapper initiators or detonators, offer clear safety and timing advantages over other means of initiating detonation in high explosives. The work described here outlines a new capability for imaging and reconstructing three-dimensional images of operating EFIs. Flyer size and intended velocity were chosen based on parameters of the imaging system. The EFI metal plasma and plastic flyer traveling at 2.5 km/s were imaged with short ~80 ps pulses spaced 153.4 ns apart. A four-camera system acquired 4 images from successive x-ray pulses from each shot. The first frame was prior to bridge burst,more » the 2 nd images the flyer about 0.16 mm above the surface but edges of the foil and/or flyer are still attached to the substrate. The 3 rd frame captures the flyer in flight, while the 4 th shows a completely detached flyer in a position that is typically beyond where slappers strike initiating explosives. Multiple acquisitions at different incident angles and advanced computed tomography reconstruction algorithms were used to produce a 3-dimensional image of the flyer at 0.16 and 0.53 mm above the surface. Both the x-ray images and the 3D reconstruction show a strong anisotropy in the shape of the flyer and underlying foil parallel vs. perpendicular to the initiating current and electrical contacts. These results provide detailed flyer morphology during the operation of the EFI.« less

  17. X-ray imaging and 3D reconstruction of in-flight exploding foil initiator flyers

    NASA Astrophysics Data System (ADS)

    Willey, T. M.; Champley, K.; Hodgin, R.; Lauderbach, L.; Bagge-Hansen, M.; May, C.; Sanchez, N.; Jensen, B. J.; Iverson, A.; van Buuren, T.

    2016-06-01

    Exploding foil initiators (EFIs), also known as slapper initiators or detonators, offer clear safety and timing advantages over other means of initiating detonation in high explosives. This work outlines a new capability for imaging and reconstructing three-dimensional images of operating EFIs. Flyer size and intended velocity were chosen based on parameters of the imaging system. The EFI metal plasma and plastic flyer traveling at 2.5 km/s were imaged with short ˜80 ps pulses spaced 153.4 ns apart. A four-camera system acquired 4 images from successive x-ray pulses from each shot. The first frame was prior to bridge burst, the 2nd images the flyer about 0.16 mm above the surface but edges of the foil and/or flyer are still attached to the substrate. The 3rd frame captures the flyer in flight, while the 4th shows a completely detached flyer in a position that is typically beyond where slappers strike initiating explosives. Multiple acquisitions at different incident angles and advanced computed tomography reconstruction algorithms were used to produce a 3-dimensional image of the flyer at 0.16 and 0.53 mm above the surface. Both the x-ray images and the 3D reconstruction show a strong anisotropy in the shape of the flyer and underlying foil parallel vs. perpendicular to the initiating current and electrical contacts. These results provide detailed flyer morphology during the operation of the EFI.

  18. X-ray imaging and 3D reconstruction of in-flight exploding foil initiator flyers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willey, T. M., E-mail: willey1@llnl.gov; Champley, K., E-mail: champley1@llnl.gov; Hodgin, R.

    Exploding foil initiators (EFIs), also known as slapper initiators or detonators, offer clear safety and timing advantages over other means of initiating detonation in high explosives. This work outlines a new capability for imaging and reconstructing three-dimensional images of operating EFIs. Flyer size and intended velocity were chosen based on parameters of the imaging system. The EFI metal plasma and plastic flyer traveling at 2.5 km/s were imaged with short ∼80 ps pulses spaced 153.4 ns apart. A four-camera system acquired 4 images from successive x-ray pulses from each shot. The first frame was prior to bridge burst, the 2nd images themore » flyer about 0.16 mm above the surface but edges of the foil and/or flyer are still attached to the substrate. The 3rd frame captures the flyer in flight, while the 4th shows a completely detached flyer in a position that is typically beyond where slappers strike initiating explosives. Multiple acquisitions at different incident angles and advanced computed tomography reconstruction algorithms were used to produce a 3-dimensional image of the flyer at 0.16 and 0.53 mm above the surface. Both the x-ray images and the 3D reconstruction show a strong anisotropy in the shape of the flyer and underlying foil parallel vs. perpendicular to the initiating current and electrical contacts. These results provide detailed flyer morphology during the operation of the EFI.« less

  19. X-ray imaging and 3D reconstruction of in-flight exploding foil initiator flyers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willey, T. M.; Champley, K.; Hodgin, R.

    Exploding foil initiators (EFIs), also known as slapper initiators or detonators, offer clear safety and timing advantages over other means of initiating detonation in high explosives. The work described here outlines a new capability for imaging and reconstructing three-dimensional images of operating EFIs. Flyer size and intended velocity were chosen based on parameters of the imaging system. The EFI metal plasma and plastic flyer traveling at 2.5 km/s were imaged with short ~80 ps pulses spaced 153.4 ns apart. A four-camera system acquired 4 images from successive x-ray pulses from each shot. The first frame was prior to bridge burst,more » the 2 nd images the flyer about 0.16 mm above the surface but edges of the foil and/or flyer are still attached to the substrate. The 3 rd frame captures the flyer in flight, while the 4 th shows a completely detached flyer in a position that is typically beyond where slappers strike initiating explosives. Multiple acquisitions at different incident angles and advanced computed tomography reconstruction algorithms were used to produce a 3-dimensional image of the flyer at 0.16 and 0.53 mm above the surface. Both the x-ray images and the 3D reconstruction show a strong anisotropy in the shape of the flyer and underlying foil parallel vs. perpendicular to the initiating current and electrical contacts. These results provide detailed flyer morphology during the operation of the EFI.« less

  20. Flow cytometry microscopy and hyperspectral imaging of microcystis, cyanobacteria and algae

    EPA Science Inventory

    The detection of algae and cyanobacteria is an important step in assessing water quality. Studies were initiated using microscopy, flow cytometry and hyperspectral imaging with two fresh water species that could be grown in the laboratory: Microcystis Aeruginosa (cyanobacteria),...

  1. Large Deformation Diffeomorphism and Momentum Based Hippocampal Shape Discrimination in Dementia of the Alzheimer type

    PubMed Central

    Wang, Lei; Beg, Faisal; Ratnanather, Tilak; Ceritoglu, Can; Younes, Laurent; Morris, John C.; Csernansky, John G.; Miller, Michael I.

    2010-01-01

    In large-deformation diffeomorphic metric mapping (LDDMM), the diffeomorphic matching of images are modeled as evolution in time, or a flow, of an associated smooth velocity vector field v controlling the evolution. The initial momentum parameterizes the whole geodesic and encodes the shape and form of the target image. Thus, methods such as principal component analysis (PCA) of the initial momentum leads to analysis of anatomical shape and form in target images without being restricted to small-deformation assumption in the analysis of linear displacements. We apply this approach to a study of dementia of the Alzheimer type (DAT). The left hippocampus in the DAT group shows significant shape abnormality while the right hippocampus shows similar pattern of abnormality. Further, PCA of the initial momentum leads to correct classification of 12 out of 18 DAT subjects and 22 out of 26 control subjects. PMID:17427733

  2. A Tiered Approach to Retinopathy of Prematurity Screening (TARP) Using a Weight Gain Predictive Model and a Telemedicine System.

    PubMed

    Gurwin, Jaclyn; Tomlinson, Lauren A; Quinn, Graham E; Ying, Gui-Shuang; Baumritter, Agnieshka; Binenbaum, Gil

    2017-01-05

    The Telemedicine Approaches to Evaluating Acute-Phase Retinopathy of Prematurity (e-ROP) Study telemedicine system of remote fundus image grading and The Children's Hospital of Philadelphia Retinopathy of Prematurity (CHOP-ROP) postnatal weight gain predictive model are 2 approaches for improving ROP screening efficiency. Current screening has low specificity for severe ROP. To describe a tiered approach to ROP screening (TARP) for identifying children who develop severe ROP using telemedicine and a predictive model synergistically. This investigation was a post hoc analysis of a cohort in the e-ROP Study (a multicenter prospective telemedicine study) and the Postnatal Growth and Retinopathy of Prematurity (G-ROP) Study (a multicenter retrospective cohort study). The setting was neonatal intensive care units at The Children's Hospital of Philadelphia and the Hospital of the University of Pennsylvania. Participants in the e-ROP Study were premature infants with a birth weight less than 1251 g and a known ROP outcome enrolled between May 25, 2011, and October 31, 2013. The G-ROP Study enrolled all infants undergoing ROP examinations with a known ROP outcome who were born between January 1, 2006, and December 31, 2011. The mean outcomes were the sensitivity for type 1 ROP, reductions in infants requiring imaging or examinations, numbers of imaging sessions and examinations, and total clinical encounters (imaging sessions and examinations combined). The following 4 screening approaches were evaluated: ROUTINE (only diagnostic examinations by an ophthalmologist), CHOP-ROP (birth weight and gestational age, with weekly weight gain initiating examinations when the risk cut point is surpassed), e-ROP IMAGING (trained reader grading of type 1 or 2 ROP initiates diagnostic examinations), and TARP (CHOP-ROP alarm initiates imaging, and imaging finding of severe ROP initiates diagnostic examinations). A total of 242 infants were included in the study, with a median birth weight of 858 g (range, 690-1035 g). The median gestational age was 27 weeks (range, 25-29 weeks). Fifty-one percent (124 of 242) were female, and 49% (118 of 242) were male. The race/ethnicity was 27.3% (66 of 242) white, 56.2% (136 of 242) black, 2.1% (5 of 242) Native American, 1.7% (4 of 242) Asian, and 12.8% (31 of 242) other. The sensitivity for detecting type 1 ROP (32 infants) was 100% (95% CI, 89.3%-100%) with each approach. With ROUTINE, 242 infants had 877 examinations; with CHOP-ROP, 184 infants had 730 examinations; with e-ROP IMAGING, 242 infants had 532 imaging sessions, and 94 infants had 345 examinations (877 patient encounters); and with TARP, 182 infants had 412 imaging sessions, and 87 infants had 322 examinations (734 patient encounters). The tiered approach to ROP screening was associated with a reduced number of examinations and imaging sessions compared with the other approaches. Applying a postnatal growth model and telemedicine system in a tiered approach may reduce the number of clinical ROP interventions more than either approach alone.

  3. Satellite images to aircraft in flight. [GEOS image transmission feasibility analysis

    NASA Technical Reports Server (NTRS)

    Camp, D.; Luers, J. K.; Kadlec, P. W.

    1977-01-01

    A study has been initiated to evaluate the feasibility of transmitting selected GOES images to aircraft in flight. Pertinent observations that could be made from satellite images on board aircraft include jet stream activity, cloud/wind motion, cloud temperatures, tropical storm activity, and location of severe weather. The basic features of the Satellite Aircraft Flight Environment System (SAFES) are described. This system uses East GOES and West GOES satellite images, which are interpreted, enhanced, and then retransmitted to designated aircraft.

  4. Attenuation-emission alignment in cardiac PET∕CT based on consistency conditions

    PubMed Central

    Alessio, Adam M.; Kinahan, Paul E.; Champley, Kyle M.; Caldwell, James H.

    2010-01-01

    Purpose: In cardiac PET and PET∕CT imaging, misaligned transmission and emission images are a common problem due to respiratory and cardiac motion. This misalignment leads to erroneous attenuation correction and can cause errors in perfusion mapping and quantification. This study develops and tests a method for automated alignment of attenuation and emission data. Methods: The CT-based attenuation map is iteratively transformed until the attenuation corrected emission data minimize an objective function based on the Radon consistency conditions. The alignment process is derived from previous work by Welch et al. [“Attenuation correction in PET using consistency information,” IEEE Trans. Nucl. Sci. 45, 3134–3141 (1998)] for stand-alone PET imaging. The process was evaluated with the simulated data and measured patient data from multiple cardiac ammonia PET∕CT exams. The alignment procedure was applied to simulations of five different noise levels with three different initial attenuation maps. For the measured patient data, the alignment procedure was applied to eight attenuation-emission combinations with initially acceptable alignment and eight combinations with unacceptable alignment. The initially acceptable alignment studies were forced out of alignment a known amount and quantitatively evaluated for alignment and perfusion accuracy. The initially unacceptable studies were compared to the proposed aligned images in a blinded side-by-side review. Results: The proposed automatic alignment procedure reduced errors in the simulated data and iteratively approaches global minimum solutions with the patient data. In simulations, the alignment procedure reduced the root mean square error to less than 5 mm and reduces the axial translation error to less than 1 mm. In patient studies, the procedure reduced the translation error by >50% and resolved perfusion artifacts after a known misalignment for the eight initially acceptable patient combinations. The side-by-side review of the proposed aligned attenuation-emission maps and initially misaligned attenuation-emission maps revealed that reviewers preferred the proposed aligned maps in all cases, except one inconclusive case. Conclusions: The proposed alignment procedure offers an automatic method to reduce attenuation correction artifacts in cardiac PET∕CT and provides a viable supplement to subjective manual realignment tools. PMID:20384256

  5. Habitable exoplanet imaging mission (HabEx): initial flight system design

    NASA Astrophysics Data System (ADS)

    Alibay, Farah; Kuan, Gary M.; Warfield, Keith R.

    2017-09-01

    The Habitable Exoplanet Imaging Mission (HabEx) is a concept for a mission to directly image planetary systems around Sun-like stars and to perform general astrophysics investigations being studied as part of a number of mission concepts for the upcoming 2020 Astrophysics Decadal Survey. HabEx would help assess the prevalence of habitable planets in our galaxy, searching in particular for potential biosignatures in the atmospheres of planets in habitable zones. More generally, HabEx would image our neighboring solar systems and characterize the variety of planets that inhabits them. Its direct imaging capability would also enable the mission to study the structure and evolution of debris disks around nearby stars, and their dynamical interaction with planets. Additionally, it will explore a number of more general astrophysics phenomena in our solar system, galaxy, and beyond, in the UV through NIR range. The exoplanet science goals lead to a mission concept with requirements for high contrast imaging and the continuous spectral coverage. The baseline for HabEx is a 4-meter diameter off-axis telescope designed to both search for habitable planets and perform general astrophysics observations, possibly combined with a starshade. In this paper, the initial flight system design for both the telescope and the starshade are presented, focusing on the key and driving requirements and subsystems, as well as the trajectory and station keeping and formation flying technique. Furthermore, some of the initial design trades undergone are described, as well as the key challenges and enablers. Finally, some of the future design and architecture trades to be performed within the flight systems as part of the continuing effort in the HabEx study are discussed.

  6. The correlation of in vivo and ex vivo tissue dielectric properties to validate electromagnetic breast imaging: initial clinical experience

    PubMed Central

    Halter, Ryan J; Zhou, Tian; Meaney, Paul M; Hartov, Alex; Barth, Richard J; Rosenkranz, Kari M; Wells, Wendy A; Kogel, Christine A; Borsic, Andrea; Rizzo, Elizabeth J; Paulsen, Keith D

    2009-01-01

    Electromagnetic (EM) breast imaging provides low-cost, safe and potentially a more specific modality for cancer detection than conventional imaging systems. A primary difficulty in validating these EM imaging modalities is that the true dielectric property values of the particular breast being imaged are not readily available on an individual subject basis. Here, we describe our initial experience in seeking to correlate tomographic EM imaging studies with discrete point spectroscopy measurements of the dielectric properties of breast tissue. The protocol we have developed involves measurement of in vivo tissue properties during partial and full mastectomy procedures in the operating room (OR) followed by ex vivo tissue property recordings in the same locations in the excised tissue specimens in the pathology laboratory immediately after resection. We have successfully applied all of the elements of this validation protocol in a series of six women with cancer diagnoses. Conductivity and permittivity gauged from ex vivo samples over the frequency range 100 Hz–8.5 GHz are found to be similar to those reported in the literature. A decrease in both conductivity and permittivity is observed when these properties are gauged from ex vivo samples instead of in vivo. We present these results in addition to a case study demonstrating how discrete point spectroscopy measurements of the tissue can be correlated and used to validate EM imaging studies. PMID:19491436

  7. Ringed impact craters on Venus: An analysis from Magellan images

    NASA Technical Reports Server (NTRS)

    Alexopoulos, Jim S.; Mckinnon, William B.

    1992-01-01

    We have analyzed cycle 1 Magellan images covering approximately 90 percent of the venusian surface and have identified 55 unequivocal peak-ring craters and multiringed impact basins. This comprehensive study (52 peak-ring craters and at least 3 multiringed impact basins) complements our earlier independent analysis of Arecibo and Venera images and initial Magellan data and that of the Magellan team.

  8. Imag(in)ing the University: Visual Sociology and Higher Education

    ERIC Educational Resources Information Center

    Metcalfe, Amy Scott

    2012-01-01

    This study examines the potential of visual sociology to expand our knowledge of higher education through the use of visual data sources and methods of analysis. Photographs and archival material form the basis of the study. The images were analyzed as being part of the initiation and fulfillment stages of the social construction of collective…

  9. Duration of oral contraceptive use predicts women's initial and subsequent subjective responses to sexual stimuli.

    PubMed

    Renfro, Kaytlin J; Rupp, Heather; Wallen, Kim

    2015-09-01

    Recent work suggests that a woman's hormonal state when first exposed to visual sexual stimuli (VSS) modulates her initial and subsequent responses to VSS. The present study investigated whether women's initial hormonal state was related to their subjective ratings of VSS, and whether this relationship differed with VSS content. We reanalyzed previously collected data from 14 naturally cycling (NC) women and 14 women taking oral contraceptives (OCs), who subjectively rated VSS at three hormonal time-points. NC women's ratings of 216 unique sexual images were collected during the menstrual, periovulatory, and luteal phases of their menstrual cycles, and OC women's ratings were collected at comparable time-points across their pill-cycles. NC women's initial hormonal state was not related to their ratings of VSS. OC women's initial hormonal state predicted their ratings of VSS with minimal contextual information and of images depicting female-to-male oral sex. Specifically, women who entered the study in the third week of their pill-cycle (OC-3 women) rated such images as less attractive at all testing sessions than did all other women. OC-3 women were also the only women to rate decontextualized VSS as unattractive at all testing sessions. These results corroborate previous studies in which women's initial hormonal state was found to predict subsequent interest in sexual stimuli. Future work, with larger samples, should more directly investigate whether OC-3 women's negative assessment of specific types of VSS reflects a reaction to the laboratory environment or a broader mechanism, wherein OC women's sexual interests decrease late in their pill-cycle. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Flow Cytometry, Microscopy and Hyperspectral Imaging of microcystis, Cyanobacteria, and Algae- SETAC

    EPA Science Inventory

    The detection of cyanobacteria algae, and picoplankton, in water is an important step in assessing water quality. Studies were initiated using fluorescence microscopy, flow cytometry and hyperspectral imaging with two fresh water species that were cultured in the laboratory:Micr...

  11. A Laboratory Approach Relating Complex Resistivity Observations to Flow and Transport in Saturated and Unsaturated Hydrologic Regimes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martins, S A; Daily, W D; Ramirez, A L

    2002-01-31

    Subsurface imaging technology, such as electric resistance tomography (ERT), is rapidly improving as a means for characterizing some soil properties of the near-surface hydrologic regime. While this information can be potentially useful in developing hydrologic models of the subsurface that are required for contaminant transport investigations, an image alone of the subsurface soil regime gives little or no information about how the site will respond to groundwater flow or contaminant transport. In fact, there is some question that tomographic imaging of soils alone can even provide meaningful values of hydraulic properties, such as the permeability structure, which is critical tomore » estimates of contaminant transport at a site. The main objective of this feasibility study was to initiate research on electrical imaging not just as a way to characterize the soil structure by mapping different soil types at a site but as a means of obtaining quantitative information about how a site will respond hydrologically to an infiltration event. To this end, a scaled system of electrode arrays was constructed that simulates the subsurface electrode distribution used at the LLNL Vadose Zone Observatory (VZO) where subsurface imaging of infiltration events has been investigated for several years. The electrode system was immersed in a 10,000-gallon tank to evaluate the fundamental relationship between ERT images and targets of a given volume that approximate infiltration-induced conductivity anomalies. With LDRD funds we have explored what can be initially learned about porous flow and transport using two important electrical imaging methods--electric resistance tomography (ERT) and electric impedance tomography (EIT). These tomographic methods involve passing currents (DC or AC) between two electrodes within or between electrode arrays while measuring the electric potential at the remaining electrodes. With the aid of a computer-based numerical inversion scheme, the potentials are used to solve for the electrical conductivity distribution in the region bounded by the electrode arrays. Groundwater movement resulting from a leak or surface spill will produce measurable conductivity changes that have been imaged using ERT or EIT. The kind of laboratory scale experiments supported by this work will help us to better understand the connection between imaged conductivity anomalies and the groundwater or contaminant flow that causes them. This work will also help to demonstrate the feasibility or value of doing lab experiments in imaging that can be applied to interpreting field-scale experiments. A secondary objective of this study was to initiate a collaboration with researchers at the Rensselaer Polytechnic Institute (RPI; Troyl NY) who are also participants in the newly created NSF Center for Subsurface Imaging and Sensing Systems (CenSSIS) which is managed in part by RPI. During the course of this study C.R. Carrigan and W. Daily visited the electromagnetic imaging lab at RPI to initiate discussions on subsurface imaging technology with Professors David Isaacson, Jon Newell, Gary Salunier and their research graduate students. A major goal of CenSSIS is to promote collaborations among researchers with imaging backgrounds in different disciplines (geosciences, biomedical, civil engineering and biomedical) that will lead to new solutions of common subsurface imaging problems. The geophysical test section constructed for this study included electrode arrays that resemble biomedical array distributions. Comparing images of the same target produced with the 4-array geophysical approach and with the biomedical imaging approach will help us to better understand differences and advantages that are characteristic of the two imaging methods. Our initial interactions with the researchers at RPI concluded that this was a viable problem to consider. The support for this subsequent research will come from a 3-year Office of Basic Energy Sciences (BES) proposal that has just received funding. This feasibility study contributed positively to the successful review and ultimately to the award of this BES funding. A letter (Appendix) from Professor Michael Silevitch, Director of CenSSIS, to Dr. Rokaya Al-Ayat, Director of the LLNL Science & Technology Office, acknowledges the contribution of this LDRD study to obtaining the Basic Energy Science grant that will fund further work in this area.« less

  12. Initial Navigation Alignment of Optical Instruments on GOES-R

    NASA Technical Reports Server (NTRS)

    Isaacson, Peter J.; DeLuccia, Frank J.; Reth, Alan D.; Igli, David A.; Carter, Delano R.

    2016-01-01

    Post-launch alignment errors for the Advanced Baseline Imager (ABI) and Geospatial Lightning Mapper (GLM) on GOES-R may be too large for the image navigation and registration (INR) processing algorithms to function without an initial adjustment to calibration parameters. We present an approach that leverages a combination of user-selected image-to-image tie points and image correlation algorithms to estimate this initial launch-induced offset and calculate adjustments to the Line of Sight Motion Compensation (LMC) parameters. We also present an approach to generate synthetic test images, to which shifts and rotations of known magnitude are applied. Results of applying the initial alignment tools to a subset of these synthetic test images are presented. The results for both ABI and GLM are within the specifications established for these tools, and indicate that application of these tools during the post-launch test (PLT) phase of GOES-R operations will enable the automated INR algorithms for both instruments to function as intended.

  13. Integrating two-photon microscopy and cryo-electron microscopy for studying the interaction of Cafeteria roenbergensis and CroV

    NASA Astrophysics Data System (ADS)

    Aghvami, Seyedmohammadali

    Cafeteria roenbergensis (Cro) is a marine zooplankton; its voracious appetite plays a significant role in regulating bacteria populations. The giant virus that lives within Cro, known as Cafeteria roenbergensis virus (CroV), has an important effect on the mortality of Cro populations. Although viral infections are extremely abundant in oceans, the complete procedure of the infection is still unknown. We study the infection process of Cro by CroV to find out whether the initial contact is through phagocytosis or CroV penetrating the host cell membrane directly. Cro is a moving at speed in the range of 10-100 um/s, therefore, there are many difficulties and challenges for traditional imaging techniques to study this viral-host interaction. We apply two-photon fluorescence microscopy to image this infection process. The image is taken at video rate (30 frame/s), which makes us able to catch the moment of interaction. We are able to image host and virus simultaneously where CroV is stained by SYBR gold dye and Cro is excited through NADH autofluorescence. For further structural biology study, we will obtain atomic level resolution information of infection. After catching the initial moment of infection, we will freeze the sample instantly and image it with cryo-electron microscope .

  14. Bio-inspired color sketch for eco-friendly printing

    NASA Astrophysics Data System (ADS)

    Safonov, Ilia V.; Tolstaya, Ekaterina V.; Rychagov, Michael N.; Lee, Hokeun; Kim, Sang Ho; Choi, Donchul

    2012-01-01

    Saving of toner/ink consumption is an important task in modern printing devices. It has a positive ecological and social impact. We propose technique for converting print-job pictures to a recognizable and pleasant color sketches. Drawing a "pencil sketch" from a photo relates to a special area in image processing and computer graphics - non-photorealistic rendering. We describe a new approach for automatic sketch generation which allows to create well-recognizable sketches and to preserve partly colors of the initial picture. Our sketches contain significantly less color dots then initial images and this helps to save toner/ink. Our bio-inspired approach is based on sophisticated edge detection technique for a mask creation and multiplication of source image with increased contrast by this mask. To construct the mask we use DoG edge detection, which is a result of blending of initial image with its blurred copy through the alpha-channel, which is created from Saliency Map according to Pre-attentive Human Vision model. Measurement of percentage of saved toner and user study proves effectiveness of proposed technique for toner saving in eco-friendly printing mode.

  15. Detonator Performance Characterization Using Multi-Frame Laser Schlieren Imaging

    NASA Astrophysics Data System (ADS)

    Clarke, S. A.; Landon, C. D.; Murphy, M. J.; Martinez, M. E.; Mason, T. A.; Thomas, K. A.

    2009-12-01

    Several experiments that are part of a phased plan to understand the evolution of detonation in a detonator from initiation shock through run to detonation to full detonation to transition to booster and booster detonation will be presented. High speed laser schlieren movies have been used to study several explosive initiation events, such as exploding bridgewires (EBW), exploding foil initiators (EFI) (or slappers), direct optical initiation (DOI), and electrostatic discharge (ESD). Additionally, a series of tests have been performed on "cut-back" detonators with varying initial pressing (IP) heights. We have also used this diagnostic to visualize a range of EBW, EFI, and DOI full-up detonators. Future applications to other explosive events such as boosters and IHE booster evaluation will be discussed. The EPIC hydrodynamic code has been used to analyze the shock fronts from the schlieren images to reverse calculate likely boundary or initial conditions to determine the temporal-spatial pressure profile across the output face of the detonator. LA-UR-05099

  16. DIRECT IMAGE PROCESSING OF CORRODING SURFACES APPLIED TO FRICTION STIR WELDING.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ISAACS,H.S.ET AL.

    An in situ process for visually locating corrosion is presented. The process visually displays image differences obtained by subtracting one digitized image from another. The difference image shows only where changes have taken place during period between the recording of the two images. Changes are due to both corrosion attack of the surface and concentration changes of dissolved corrosion products in solution. Indicators added to the solution assist by decorating sites of corrosion as diffusion and convection of the dissolved products increase the size of the affected region. A study of the initial stages of corrosion of a friction stirmore » welded Al alloy 7075 has been performed using this imaging technique. Pitting potential measurements suggest that there was an initial increased sensitivity to corrosion. The difference image technique demonstrated that it was due to a reformation of the passive film that occurs with Zn containing Al alloys which occurs preferentially along flow protected regions. The most susceptible region of the weld was found to be where both limited deformation and thermal transients are produced during welding.« less

  17. Infrared traffic image enhancement algorithm based on dark channel prior and gamma correction

    NASA Astrophysics Data System (ADS)

    Zheng, Lintao; Shi, Hengliang; Gu, Ming

    2017-07-01

    The infrared traffic image acquired by the intelligent traffic surveillance equipment has low contrast, little hierarchical differences in perceptions of image and the blurred vision effect. Therefore, infrared traffic image enhancement, being an indispensable key step, is applied to nearly all infrared imaging based traffic engineering applications. In this paper, we propose an infrared traffic image enhancement algorithm that is based on dark channel prior and gamma correction. In existing research dark channel prior, known as a famous image dehazing method, here is used to do infrared image enhancement for the first time. Initially, in the proposed algorithm, the original degraded infrared traffic image is transformed with dark channel prior as the initial enhanced result. A further adjustment based on the gamma curve is needed because initial enhanced result has lower brightness. Comprehensive validation experiments reveal that the proposed algorithm outperforms the current state-of-the-art algorithms.

  18. Magnetohydrodynamic modelling of exploding foil initiators

    NASA Astrophysics Data System (ADS)

    Neal, William

    2015-06-01

    Magnetohydrodynamic (MHD) codes are currently being developed, and used, to predict the behaviour of electrically-driven flyer-plates. These codes are of particular interest to the design of exploding foil initiator (EFI) detonators but there is a distinct lack of comparison with high-fidelity experimental data. This study aims to compare a MHD code with a collection of temporally and spatially resolved diagnostics including PDV, dual-axis imaging and streak imaging. The results show the code's excellent representation of the flyer-plate launch and highlight features within the experiment that the model fails to capture.

  19. Initial Navigation Alignment of Optical Instruments on GOES-R

    NASA Astrophysics Data System (ADS)

    Isaacson, P.; DeLuccia, F.; Reth, A. D.; Igli, D. A.; Carter, D.

    2016-12-01

    The GOES-R satellite is the first in NOAA's next-generation series of geostationary weather satellites. In addition to a number of space weather sensors, it will carry two principal optical earth-observing instruments, the Advanced Baseline Imager (ABI) and the Geostationary Lightning Mapper (GLM). During launch, currently scheduled for November of 2016, the alignment of these optical instruments is anticipated to shift from that measured during pre-launch characterization. While both instruments have image navigation and registration (INR) processing algorithms to enable automated geolocation of the collected data, the launch-derived misalignment may be too large for these approaches to function without an initial adjustment to calibration parameters. The parameters that may require adjustment are for Line of Sight Motion Compensation (LMC), and the adjustments will be estimated on orbit during the post-launch test (PLT) phase. We have developed approaches to estimate the initial alignment errors for both ABI and GLM image products. Our approaches involve comparison of ABI and GLM images collected during PLT to a set of reference ("truth") images using custom image processing tools and other software (the INR Performance Assessment Tool Set, or "IPATS") being developed for other INR assessments of ABI and GLM data. IPATS is based on image correlation approaches to determine offsets between input and reference images, and these offsets are the fundamental input to our estimate of the initial alignment errors. Initial testing of our alignment algorithms on proxy datasets lends high confidence that their application will determine the initial alignment errors to within sufficient accuracy to enable the operational INR processing approaches to proceed in a nominal fashion. We will report on the algorithms, implementation approach, and status of these initial alignment tools being developed for the GOES-R ABI and GLM instruments.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potter, T.; McClain, C.J.; Shafer, R.B.

    Ten patients were prospectively studied using 99mTc-PIPIDA imaging to evaluate the effects of fasting and parenteral alimentation on gallbladder function. Three of ten patients had initial nonvisualization of the gallbladder for up to 2 hr, yet had normal visualization on repeat imaging performed after resumption of oral intake or after parenteral alimentation was discontinued. 99mTc-PIPIDA imaging should be interpreted with caution in patients fitting into either of these groups.

  1. Magnetic resonance imaging (MRI) and relaxation time mapping of concrete

    NASA Astrophysics Data System (ADS)

    Beyea, Steven Donald

    2001-07-01

    The use of Magnetic Resonance Imaging (MRI) of water in concrete is presented. This thesis will approach the problem of MR imaging of concrete by attempting to design new methods, suited to concrete materials, rather than attempting to force the material to suit the method. A number of techniques were developed, which allow the spatial observation of water in concrete in up to three dimensions, and permits the determination of space resolved moisture content, as well as local NMR relaxation times. These methods are all based on the Single-Point Imaging (SPI) method. The development of these new methods will be described, and the techniques validated using phantom studies. The study of one-dimensional moisture transport in drying concrete was performed using SPI. This work examined the effect of initial mixture proportions and hydration time on the drying behaviour of concrete, over a period of three months. Studies of drying concrete were also performed using spatial mapping of the spin-lattice (T1) and effective spin-spin (T2*) relaxation times, thereby permitting the observation of changes in the water occupied pore surface-to-volume ratio (S/V) as a function of drying. Results of this work demonstrated changes in the S/V due to drying, hydration and drying induced microcracking. Three-dimensional MRI of concrete was performed using SPRITE (Single-Point Ramped Imaging with T1 Enhancement) and turboSPI (turbo Single Point Imaging). While SPRITE allows for weighting of MR images using T 1 and T2*, turboSPI allows T2 weighting of the resulting images. Using relaxation weighting it was shown to be possible to discriminate between water contained within a hydrated cement matrix, and water in highly porous aggregates, used to produce low-density concrete. Three dimensional experiments performed using SPRITE and turboSPI examined the role of self-dessication, drying, initial aggregate saturation and initial mixture conditions on the transport of moisture between porous aggregates and the hydrated matrix. The results demonstrate that water is both added and removed from the aggregates, depending upon the physical conditions. The images also appear to show an influx of cement products into cracks in the solid aggregate. (Abstract shortened by UMI.)

  2. Optimization of scan initiation timing after 11C-methionine administration for the diagnosis of suspected recurrent brain tumors.

    PubMed

    Nakajima, Reiko; Abe, Koichiro; Momose, Mitsuru; Fukushima, Kenji; Matsuo, Yuka; Kimura, Ken; Kondo, Chisato; Sakai, Shuji

    2017-02-01

    11 C-Methionine (MET) positron emission tomography (PET) imaging is a valuable technique for the evaluation of primary and recurrent brain tumors. Many studies have used MET-PET for data acquisition starting at 20 min after the tracer injection, while others have used scan initiation times at 5-15 min postinjection. No previous studies have identified the best acquisition timing during MET-PET imaging for suspected recurrent brain tumors. Here we sought to determine the optimal scan initiating timing after MET administration for the detection of recurrent brain tumors. Twenty-three consecutive patients with suspected recurrent brain tumors underwent MET-PET examinations. Brain PET images were reconstructed from the four serial data sets (10-15, 15-20, 20-25, and 25-30 min postinjection) that were obtained using the list-mode acquisition technique. We determined the maximal standardized uptake values (SUVmax) of the target lesions and the target-to-normal-tissue ratios (TNRs), calculated as the SUVmax to the SUVmean of a region of interest placed on the normal contralateral frontal cortex. Target lesions without significant MET uptake were excluded. Thirty-one lesions from 23 patients were enrolled. There were no significant differences in MET SUVmax or TNR values among the PET images that were reconstructed with the data extracted from the four phases postinjection. The MET uptake in the suspected recurrent brain tumors was comparable among all data extraction time phases from 10 to 30 min postinjection. The scan initiation time of MET-PET at 10 min after the injection is allowable for the detection of recurrent brain tumors. The registration identification number of the original study is 1002.

  3. Beryllium liner implosion experiments on the Z accelerator in preparation for magnetized liner inertial fusiona)

    NASA Astrophysics Data System (ADS)

    McBride, R. D.; Martin, M. R.; Lemke, R. W.; Greenly, J. B.; Jennings, C. A.; Rovang, D. C.; Sinars, D. B.; Cuneo, M. E.; Herrmann, M. C.; Slutz, S. A.; Nakhleh, C. W.; Ryutov, D. D.; Davis, J.-P.; Flicker, D. G.; Blue, B. E.; Tomlinson, K.; Schroen, D.; Stamm, R. M.; Smith, G. E.; Moore, J. K.; Rogers, T. J.; Robertson, G. K.; Kamm, R. J.; Smith, I. C.; Savage, M.; Stygar, W. A.; Rochau, G. A.; Jones, M.; Lopez, M. R.; Porter, J. L.; Matzen, M. K.

    2013-05-01

    Multiple experimental campaigns have been executed to study the implosions of initially solid beryllium (Be) liners (tubes) on the Z pulsed-power accelerator. The implosions were driven by current pulses that rose from 0 to 20 MA in either 100 or 200 ns (200 ns for pulse shaping experiments). These studies were conducted in support of the recently proposed Magnetized Liner Inertial Fusion concept [Slutz et al., Phys. Plasmas 17, 056303 (2010)], as well as for exploring novel equation-of-state measurement techniques. The experiments used thick-walled liners that had an aspect ratio (initial outer radius divided by initial wall thickness) of either 3.2, 4, or 6. From these studies, we present three new primary results. First, we present radiographic images of imploding Be liners, where each liner contained a thin aluminum sleeve for enhancing the contrast and visibility of the liner's inner surface in the images. These images allow us to assess the stability of the liner's inner surface more accurately and more directly than was previously possible. Second, we present radiographic images taken early in the implosion (prior to any motion of the liner's inner surface) of a shockwave propagating radially inward through the liner wall. Radial mass density profiles from these shock compression experiments are contrasted with profiles from experiments where the Z accelerator's pulse shaping capabilities were used to achieve shockless ("quasi-isentropic") liner compression. Third, we present "micro-Ḃ" measurements of azimuthal magnetic field penetration into the initially vacuum-filled interior of a shocked liner. Our measurements and simulations reveal that the penetration commences shortly after the shockwave breaks out from the liner's inner surface. The field then accelerates this low-density "precursor" plasma to the axis of symmetry.

  4. Beryllium liner implosion experiments on the Z accelerator in preparation for magnetized liner inertial fusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McBride, R. D.; Martin, M. R.; Lemke, R. W.

    Multiple experimental campaigns have been executed to study the implosions of initially solid beryllium (Be) liners (tubes) on the Z pulsed-power accelerator. The implosions were driven by current pulses that rose from 0 to 20 MA in either 100 or 200 ns (200 ns for pulse shaping experiments). These studies were conducted in support of the recently proposed Magnetized Liner Inertial Fusion concept [Slutz et al., Phys. Plasmas 17, 056303 (2010)], as well as for exploring novel equation-of-state measurement techniques. The experiments used thick-walled liners that had an aspect ratio (initial outer radius divided by initial wall thickness) of eithermore » 3.2, 4, or 6. From these studies, we present three new primary results. First, we present radiographic images of imploding Be liners, where each liner contained a thin aluminum sleeve for enhancing the contrast and visibility of the liner's inner surface in the images. These images allow us to assess the stability of the liner's inner surface more accurately and more directly than was previously possible. Second, we present radiographic images taken early in the implosion (prior to any motion of the liner's inner surface) of a shockwave propagating radially inward through the liner wall. Radial mass density profiles from these shock compression experiments are contrasted with profiles from experiments where the Z accelerator's pulse shaping capabilities were used to achieve shockless (“quasi-isentropic”) liner compression. Third, we present “micro-B-dot ” measurements of azimuthal magnetic field penetration into the initially vacuum-filled interior of a shocked liner. Our measurements and simulations reveal that the penetration commences shortly after the shockwave breaks out from the liner's inner surface. The field then accelerates this low-density “precursor” plasma to the axis of symmetry.« less

  5. Imaging cardiac activation sequence during ventricular tachycardia in a canine model of nonischemic heart failure.

    PubMed

    Han, Chengzong; Pogwizd, Steven M; Yu, Long; Zhou, Zhaoye; Killingsworth, Cheryl R; He, Bin

    2015-01-15

    Noninvasive cardiac activation imaging of ventricular tachycardia (VT) is important in the clinical diagnosis and treatment of arrhythmias in heart failure (HF) patients. This study investigated the ability of the three-dimensional cardiac electrical imaging (3DCEI) technique for characterizing the activation patterns of spontaneously occurring and norepinephrine (NE)-induced VTs in a newly developed arrhythmogenic canine model of nonischemic HF. HF was induced by aortic insufficiency followed by aortic constriction in three canines. Up to 128 body-surface ECGs were measured simultaneously with bipolar recordings from up to 232 intramural sites in a closed-chest condition. Data analysis was performed on the spontaneously occurring VTs (n=4) and the NE-induced nonsustained VTs (n=8) in HF canines. Both spontaneously occurring and NE-induced nonsustained VTs initiated by a focal mechanism primarily from the subendocardium, but occasionally from the subepicardium of left ventricle. Most focal initiation sites were located at apex, right ventricular outflow tract, and left lateral wall. The NE-induced VTs were longer, more rapid, and had more focal sites than the spontaneously occurring VTs. Good correlation was obtained between imaged activation sequence and direct measurements (averaged correlation coefficient of ∼0.70 over 135 VT beats). The reconstructed initiation sites were ∼10 mm from measured initiation sites, suggesting good localization in such a large animal model with cardiac size similar to a human. Both spontaneously occurring and NE-induced nonsustained VTs had focal initiation in this canine model of nonischemic HF. 3DCEI is feasible to image the activation sequence and help define arrhythmia mechanism of nonischemic HF-associated VTs. Copyright © 2015 the American Physiological Society.

  6. Do Orthopaedic Oncologists Agree on the Diagnosis and Treatment of Cartilage Tumors of the Appendicular Skeleton?

    PubMed

    Zamora, Tomas; Urrutia, Julio; Schweitzer, Daniel; Amenabar, Pedro Pablo; Botello, Eduardo

    2017-09-01

    Distinguishing a benign enchondroma from a low-grade chondrosarcoma is a common diagnostic challenge for orthopaedic oncologists. Low interrater agreement has been observed for the diagnosis of cartilaginous neoplasms among radiologists and pathologists, but, to our knowledge, no study has evaluated inter- and intraobserver agreement among orthopaedic oncologists grading these lesions using initial clinical and imaging information. Determining such agreement is important since it reflects the certainty in the diagnosis by orthopaedic oncologists. Agreement also is important as it will guide future treatment and prognosis, considering that there is no gold standard for diagnosis of these lesions. (1) to determine inter- and intraobserver agreement among a multinational panel of expert orthopaedic oncologists in diagnosing cartilaginous neoplasms based on their assessment of clinical symptoms and imaging at diagnosis. (2) To describe the most important clinical and imaging features that experts use during the initial diagnostic process. (3) To determine interobserver agreement for proposed initial treatment strategies for cartilaginous neoplasms by this panel of evaluators. Thirty-nine patients with intramedullary cartilaginous neoplasms of the appendicular skeleton of various histopathologic grades were selected and classified as having benign, low-grade malignant, or intermediate- or high-grade malignant neoplasms by 10 experienced orthopaedic oncologists based on clinical and imaging information. Additionally, they chose the three most important clinical or imaging features for the diagnosis of these neoplasms, and they proposed a treatment strategy for each patient. The Kappa coefficient (κ) was used to determine inter- and intraobserver agreement. Inter- and intraobserver agreements were only fair to good, κ = 0.44(95% CI, 0.41-0.48) and κ = 0.62 (95% CI, 0.52-0.72), respectively. The three factors most frequently identified as helpful in making the diagnosis by our panel were cortical involvement in 65% of evaluations (253/390), neoplasm size in 51% (198/390), and pain in 50% (194/390). The interobserver agreement for the proposed initial treatment strategy after diagnosis was poor (κ = 0.21; 95% CI, 0.18-0.24). This study showed barely fair interobserver and fair to good intraobserver agreement for grading of intramedullary cartilaginous neoplasms by orthopaedic oncologists using initial clinical and imaging findings. These results reflect the insufficient guidance interpreting clinical and imaging features, and the limitations of the systems we use today when making these diagnoses. In the same way, they generate concern for the implications that this may have on different treatment strategies and the future prognosis of our patients. Future studies should build on these observations and focus on clarifying our criteria of diagnosis so that treatment recommendations are standardized regardless of the treating institution or oncologist. Level III, diagnostic study.

  7. Development of a personalized training system using the Lung Image Database Consortium and Image Database resource Initiative Database.

    PubMed

    Lin, Hongli; Wang, Weisheng; Luo, Jiawei; Yang, Xuedong

    2014-12-01

    The aim of this study was to develop a personalized training system using the Lung Image Database Consortium (LIDC) and Image Database resource Initiative (IDRI) Database, because collecting, annotating, and marking a large number of appropriate computed tomography (CT) scans, and providing the capability of dynamically selecting suitable training cases based on the performance levels of trainees and the characteristics of cases are critical for developing a efficient training system. A novel approach is proposed to develop a personalized radiology training system for the interpretation of lung nodules in CT scans using the Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI) database, which provides a Content-Boosted Collaborative Filtering (CBCF) algorithm for predicting the difficulty level of each case of each trainee when selecting suitable cases to meet individual needs, and a diagnostic simulation tool to enable trainees to analyze and diagnose lung nodules with the help of an image processing tool and a nodule retrieval tool. Preliminary evaluation of the system shows that developing a personalized training system for interpretation of lung nodules is needed and useful to enhance the professional skills of trainees. The approach of developing personalized training systems using the LIDC/IDRL database is a feasible solution to the challenges of constructing specific training program in terms of cost and training efficiency. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  8. A Probabilistic Feature Map-Based Localization System Using a Monocular Camera.

    PubMed

    Kim, Hyungjin; Lee, Donghwa; Oh, Taekjun; Choi, Hyun-Taek; Myung, Hyun

    2015-08-31

    Image-based localization is one of the most widely researched localization techniques in the robotics and computer vision communities. As enormous image data sets are provided through the Internet, many studies on estimating a location with a pre-built image-based 3D map have been conducted. Most research groups use numerous image data sets that contain sufficient features. In contrast, this paper focuses on image-based localization in the case of insufficient images and features. A more accurate localization method is proposed based on a probabilistic map using 3D-to-2D matching correspondences between a map and a query image. The probabilistic feature map is generated in advance by probabilistic modeling of the sensor system as well as the uncertainties of camera poses. Using the conventional PnP algorithm, an initial camera pose is estimated on the probabilistic feature map. The proposed algorithm is optimized from the initial pose by minimizing Mahalanobis distance errors between features from the query image and the map to improve accuracy. To verify that the localization accuracy is improved, the proposed algorithm is compared with the conventional algorithm in a simulation and realenvironments.

  9. A Probabilistic Feature Map-Based Localization System Using a Monocular Camera

    PubMed Central

    Kim, Hyungjin; Lee, Donghwa; Oh, Taekjun; Choi, Hyun-Taek; Myung, Hyun

    2015-01-01

    Image-based localization is one of the most widely researched localization techniques in the robotics and computer vision communities. As enormous image data sets are provided through the Internet, many studies on estimating a location with a pre-built image-based 3D map have been conducted. Most research groups use numerous image data sets that contain sufficient features. In contrast, this paper focuses on image-based localization in the case of insufficient images and features. A more accurate localization method is proposed based on a probabilistic map using 3D-to-2D matching correspondences between a map and a query image. The probabilistic feature map is generated in advance by probabilistic modeling of the sensor system as well as the uncertainties of camera poses. Using the conventional PnP algorithm, an initial camera pose is estimated on the probabilistic feature map. The proposed algorithm is optimized from the initial pose by minimizing Mahalanobis distance errors between features from the query image and the map to improve accuracy. To verify that the localization accuracy is improved, the proposed algorithm is compared with the conventional algorithm in a simulation and realenvironments. PMID:26404284

  10. Advanced Technologies for the Study of Earth Systems.

    ERIC Educational Resources Information Center

    Sproull, Jim

    1991-01-01

    Describes the Joint Education Initiative (JEdI) project designed to instruct teachers how to access scientific data and images for classroom instruction. Presents a sample CD-ROM classroom computer activity that illustrates how CD images and databases can be combined for a science investigation comparing topography to gravity anomalies. (MCO)

  11. Guided color consistency optimization for image mosaicking

    NASA Astrophysics Data System (ADS)

    Xie, Renping; Xia, Menghan; Yao, Jian; Li, Li

    2018-01-01

    This paper studies the problem of color consistency correction for sequential images with diverse color characteristics. Existing algorithms try to adjust all images to minimize color differences among images under a unified energy framework, however, the results are prone to presenting a consistent but unnatural appearance when the color difference between images is large and diverse. In our approach, this problem is addressed effectively by providing a guided initial solution for the global consistency optimization, which avoids converging to a meaningless integrated solution. First of all, to obtain the reliable intensity correspondences in overlapping regions between image pairs, we creatively propose the histogram extreme point matching algorithm which is robust to image geometrical misalignment to some extents. In the absence of the extra reference information, the guided initial solution is learned from the major tone of the original images by searching some image subset as the reference, whose color characteristics will be transferred to the others via the paths of graph analysis. Thus, the final results via global adjustment will take on a consistent color similar to the appearance of the reference image subset. Several groups of convincing experiments on both the synthetic dataset and the challenging real ones sufficiently demonstrate that the proposed approach can achieve as good or even better results compared with the state-of-the-art approaches.

  12. Development of a small prototype for a proof-of-concept of OpenPET imaging

    NASA Astrophysics Data System (ADS)

    Yamaya, Taiga; Yoshida, Eiji; Inaniwa, Taku; Sato, Shinji; Nakajima, Yasunori; Wakizaka, Hidekatsu; Kokuryo, Daisuke; Tsuji, Atsushi; Mitsuhashi, Takayuki; Kawai, Hideyuki; Tashima, Hideaki; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo; Haneishi, Hideaki; Suga, Mikio; Kinouchi, Shoko

    2011-02-01

    The OpenPET geometry is our new idea to visualize a physically opened space between two detector rings. In this paper, we developed the first small prototype to show a proof-of-concept of OpenPET imaging. Two detector rings of 110 mm diameter and 42 mm axial length were placed with a gap of 42 mm. The basic imaging performance was confirmed through phantom studies; the open imaging was realized at the cost of slight loss of axial resolution and 24% loss of sensitivity. For a proof-of-concept of PET image-guided radiation therapy, we carried out the in-beam tests with 11C radioactive beam irradiation in the heavy ion medical accelerator in Chiba to visualize in situ distribution of primary particles stopped in a phantom. We showed that PET images corresponding to dose distribution were obtained. For an initial proof-of-concept of real-time multimodal imaging, we measured a tumor-inoculated mouse with 18F-FDG, and an optical image of the mouse body surface was taken during the PET measurement by inserting a digital camera in the ring gap. We confirmed that the tumor in the gap was clearly visualized. The result also showed the extension effect of an axial field-of-view (FOV); a large axial FOV of 126 mm was obtained with the detectors that originally covered only an 84 mm axial FOV. In conclusion, our initial imaging studies showed promising performance of the OpenPET.

  13. Computer-aided classification of breast masses using contrast-enhanced digital mammograms

    NASA Astrophysics Data System (ADS)

    Danala, Gopichandh; Aghaei, Faranak; Heidari, Morteza; Wu, Teresa; Patel, Bhavika; Zheng, Bin

    2018-02-01

    By taking advantages of both mammography and breast MRI, contrast-enhanced digital mammography (CEDM) has emerged as a new promising imaging modality to improve efficacy of breast cancer screening and diagnosis. The primary objective of study is to develop and evaluate a new computer-aided detection and diagnosis (CAD) scheme of CEDM images to classify between malignant and benign breast masses. A CEDM dataset consisting of 111 patients (33 benign and 78 malignant) was retrospectively assembled. Each case includes two types of images namely, low-energy (LE) and dual-energy subtracted (DES) images. First, CAD scheme applied a hybrid segmentation method to automatically segment masses depicting on LE and DES images separately. Optimal segmentation results from DES images were also mapped to LE images and vice versa. Next, a set of 109 quantitative image features related to mass shape and density heterogeneity was initially computed. Last, four multilayer perceptron-based machine learning classifiers integrated with correlationbased feature subset evaluator and leave-one-case-out cross-validation method was built to classify mass regions depicting on LE and DES images, respectively. Initially, when CAD scheme was applied to original segmentation of DES and LE images, the areas under ROC curves were 0.7585+/-0.0526 and 0.7534+/-0.0470, respectively. After optimal segmentation mapping from DES to LE images, AUC value of CAD scheme significantly increased to 0.8477+/-0.0376 (p<0.01). Since DES images eliminate overlapping effect of dense breast tissue on lesions, segmentation accuracy was significantly improved as compared to regular mammograms, the study demonstrated that computer-aided classification of breast masses using CEDM images yielded higher performance.

  14. Real-time quantitative fluorescence imaging using a single snapshot optical properties technique for neurosurgical guidance

    NASA Astrophysics Data System (ADS)

    Valdes, Pablo A.; Angelo, Joseph; Gioux, Sylvain

    2015-03-01

    Fluorescence imaging has shown promise as an adjunct to improve the extent of resection in neurosurgery and oncologic surgery. Nevertheless, current fluorescence imaging techniques do not account for the heterogeneous attenuation effects of tissue optical properties. In this work, we present a novel imaging system that performs real time quantitative fluorescence imaging using Single Snapshot Optical Properties (SSOP) imaging. We developed the technique and performed initial phantom studies to validate the quantitative capabilities of the system for intraoperative feasibility. Overall, this work introduces a novel real-time quantitative fluorescence imaging method capable of being used intraoperatively for neurosurgical guidance.

  15. Diffraction enhance x-ray imaging for quantitative phase contrast studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agrawal, A. K.; Singh, B., E-mail: balwants@rrcat.gov.in; Kashyap, Y. S.

    2016-05-23

    Conventional X-ray imaging based on absorption contrast permits limited visibility of feature having small density and thickness variations. For imaging of weakly absorbing material or materials possessing similar densities, a novel phase contrast imaging techniques called diffraction enhanced imaging has been designed and developed at imaging beamline Indus-2 RRCAT Indore. The technique provides improved visibility of the interfaces and show high contrast in the image forsmall density or thickness gradients in the bulk. This paper presents basic principle, instrumentation and analysis methods for this technique. Initial results of quantitative phase retrieval carried out on various samples have also been presented.

  16. The implementation of an AR (augmented reality) approach to support mammographic interpretation training: an initial feasibility study

    NASA Astrophysics Data System (ADS)

    Tang, Qiang; Chen, Yan; Gale, Alastair G.

    2017-03-01

    Appropriate feedback plays an important role in optimising mammographic interpretation training whilst also ensuring good interpretation performance. The traditional keyboard, mouse and workstation technical approach has a critical limitation in providing supplementary image-related information and providing complex feedback in real time. Augmented Reality (AR) provides a possible superior approach in this situation, as feedback can be provided directly overlaying the displayed mammographic images so making a generic approach which can also be vendor neutral. In this study, radiological feedback was dynamically remapped virtually into the real world, using perspective transformation, in order to provide a richer user experience in mammographic interpretation training. This is an initial attempt of an AR approach to dynamically superimpose pre-defined feedback information of a DICOM image on top of a radiologist's view, whilst the radiologist is examining images on a clinical workstation. The study demonstrates the feasibility of the approach, although there are limitations on interactive operations which are due to the hardware used. The results of this fully functional approach provide appropriate feedback/image correspondence in a simulated mammographic interpretation environment. Thus, it is argued that employing AR is a feasible way to provide rich feedback in the delivery of mammographic interpretation training.

  17. Processing Translational Motion Sequences.

    DTIC Science & Technology

    1982-10-01

    the initial ROADSIGN image using a (del)**2g mask with a width of 5 pixels The distinctiveness values were computed using features which were 5x5 pixel...the initial step size of the local search quite large. 34 4. EX P R g NTg The following experiments were performed using the roadsign and industrial...the initial image of the sequence. The third experiment involves processing the roadsign image sequence using the features extracted at the positions

  18. Giant cell arteritis: diagnostic accuracy of MR imaging of superficial cranial arteries in initial diagnosis-results from a multicenter trial.

    PubMed

    Klink, Thorsten; Geiger, Julia; Both, Marcus; Ness, Thomas; Heinzelmann, Sonja; Reinhard, Matthias; Holl-Ulrich, Konstanze; Duwendag, Dirk; Vaith, Peter; Bley, Thorsten Alexander

    2014-12-01

    To assess the diagnostic accuracy of contrast material-enhanced magnetic resonance (MR) imaging of superficial cranial arteries in the initial diagnosis of giant cell arteritis ( GCA giant cell arteritis ). Following institutional review board approval and informed consent, 185 patients suspected of having GCA giant cell arteritis were included in a prospective three-university medical center trial. GCA giant cell arteritis was diagnosed or excluded clinically in all patients (reference standard [final clinical diagnosis]). In 53.0% of patients (98 of 185), temporal artery biopsy ( TAB temporal artery biopsy ) was performed (diagnostic standard [ TAB temporal artery biopsy ]). Two observers independently evaluated contrast-enhanced T1-weighted MR images of superficial cranial arteries by using a four-point scale. Diagnostic accuracy, involvement pattern, and systemic corticosteroid ( sCS systemic corticosteroid ) therapy effects were assessed in comparison with the reference standard (total study cohort) and separately in comparison with the diagnostic standard TAB temporal artery biopsy ( TAB temporal artery biopsy subcohort). Statistical analysis included diagnostic accuracy parameters, interobserver agreement, and receiver operating characteristic analysis. Sensitivity of MR imaging was 78.4% and specificity was 90.4% for the total study cohort, and sensitivity was 88.7% and specificity was 75.0% for the TAB temporal artery biopsy subcohort (first observer). Diagnostic accuracy was comparable for both observers, with good interobserver agreement ( TAB temporal artery biopsy subcohort, κ = 0.718; total study cohort, κ = 0.676). MR imaging scores were significantly higher in patients with GCA giant cell arteritis -positive results than in patients with GCA giant cell arteritis -negative results ( TAB temporal artery biopsy subcohort and total study cohort, P < .001). Diagnostic accuracy of MR imaging was high in patients without and with sCS systemic corticosteroid therapy for 5 days or fewer (area under the curve, ≥0.9) and was decreased in patients receiving sCS systemic corticosteroid therapy for 6-14 days. In 56.5% of patients with TAB temporal artery biopsy -positive results (35 of 62), MR imaging displayed symmetrical and simultaneous inflammation of arterial segments. MR imaging of superficial cranial arteries is accurate in the initial diagnosis of GCA giant cell arteritis . Sensitivity probably decreases after more than 5 days of sCS systemic corticosteroid therapy; thus, imaging should not be delayed. Clinical trial registration no. DRKS00000594 . © RSNA, 2014.

  19. Cumulative effective dose associated with radiography and CT of adolescents with spinal injuries.

    PubMed

    Lemburg, Stefan P; Peters, Soeren A; Roggenland, Daniela; Nicolas, Volkmar; Heyer, Christoph M

    2010-12-01

    The purpose of this study was to analyze the quantity and distribution of cumulative effective doses in diagnostic imaging of adolescents with spinal injuries. At a level 1 trauma center from July 2003 through June 2009, imaging procedures during initial evaluation and hospitalization and after discharge of all patients 10-20 years old with spinal fractures were retrospectively analyzed. The cumulative effective doses for all imaging studies were calculated, and the doses to patients with spinal injuries who had multiple traumatic injuries were compared with the doses to patients with spinal injuries but without multiple injuries. The significance level was set at 5%. Imaging studies of 72 patients (32 with multiple injuries; average age, 17.5 years) entailed a median cumulative effective dose of 18.89 mSv. Patients with multiple injuries had a significantly higher total cumulative effective dose (29.70 versus 10.86 mSv, p < 0.001) mainly owing to the significantly higher CT-related cumulative effective dose to multiple injury patients during the initial evaluation (18.39 versus 2.83 mSv, p < 0.001). Overall, CT accounted for 86% of the total cumulative effective dose. Adolescents with spinal injuries receive a cumulative effective dose equal to that of adult trauma patients and nearly three times that of pediatric trauma patients. Areas of focus in lowering cumulative effective dose should be appropriate initial estimation of trauma severity and careful selection of CT scan parameters.

  20. Initial clinical experience with a video-based patient positioning system.

    PubMed

    Johnson, L S; Milliken, B D; Hadley, S W; Pelizzari, C A; Haraf, D J; Chen, G T

    1999-08-01

    To report initial clinical experience with an interactive, video-based patient positioning system that is inexpensive, quick, accurate, and easy to use. System hardware includes two black-and-white CCD cameras, zoom lenses, and a PC equipped with a frame grabber. Custom software is used to acquire and archive video images, as well as to display real-time subtraction images revealing patient misalignment in multiple views. Two studies are described. In the first study, video is used to document the daily setup histories of 5 head and neck patients. Time-lapse cine loops are generated for each patient and used to diagnose and correct common setup errors. In the second study, 6 twice-daily (BID) head and neck patients are positioned according to the following protocol: at AM setups conventional treatment room lasers are used; at PM setups lasers are used initially and then video is used for 1-2 minutes to fine-tune the patient position. Lateral video images and lateral verification films are registered off-line to compare the distribution of setup errors per patient, with and without video assistance. In the first study, video images were used to determine the accuracy of our conventional head and neck setup technique, i.e., alignment of lightcast marks and surface anatomy to treatment room lasers and the light field. For this initial cohort of patients, errors ranged from sigma = 5 to 7 mm and were patient-specific. Time-lapse cine loops of the images revealed sources of the error, and as a result, our localization techniques and immobilization device were modified to improve setup accuracy. After the improvements, conventional setup errors were reduced to sigma = 3 to 5 mm. In the second study, when a stereo pair of live subtraction images were introduced to perform daily "on-line" setup correction, errors were reduced to sigma = 1 to 3 mm. Results depended on patient health and cooperation and the length of time spent fine-tuning the position. An interactive, video-based patient positioning system was shown to reduce setup errors to within 1 to 3 mm in head and neck patients, without a significant increase in overall treatment time or labor-intensive procedures. Unlike retrospective portal image analysis, use of two live-video images provides the therapists with immediate feedback and allows for true 3-D positioning and correction of out-of-plane rotation before radiation is delivered. With significant improvement in head and neck alignment and the elimination of setup errors greater than 3 to 5 mm, margins associated with treatment volumes potentially can be reduced, thereby decreasing normal tissue irradiation.

  1. Secure steganographic communication algorithm based on self-organizing patterns.

    PubMed

    Saunoriene, Loreta; Ragulskis, Minvydas

    2011-11-01

    A secure steganographic communication algorithm based on patterns evolving in a Beddington-de Angelis-type predator-prey model with self- and cross-diffusion is proposed in this paper. Small perturbations of initial states of the system around the state of equilibrium result in the evolution of self-organizing patterns. Small differences between initial perturbations result in slight differences also in the evolving patterns. It is shown that the generation of interpretable target patterns cannot be considered as a secure mean of communication because contours of the secret image can be retrieved from the cover image using statistical techniques if only it represents small perturbations of the initial states of the system. An alternative approach when the cover image represents the self-organizing pattern that has evolved from initial states perturbed using the dot-skeleton representation of the secret image can be considered as a safe visual communication technique protecting both the secret image and communicating parties.

  2. Experiments and simulations of Richtmyer-Meshkov Instability with measured,volumetric initial conditions

    NASA Astrophysics Data System (ADS)

    Sewell, Everest; Ferguson, Kevin; Jacobs, Jeffrey; Greenough, Jeff; Krivets, Vitaliy

    2016-11-01

    We describe experiments of single-shock Richtmyer-Meskhov Instability (RMI) performed on the shock tube apparatus at the University of Arizona in which the initial conditions are volumetrically imaged prior to shock wave arrival. Initial perturbations play a major role in the evolution of RMI, and previous experimental efforts only capture a single plane of the initial condition. The method presented uses a rastered laser sheet to capture additional images throughout the depth of the initial condition immediately before the shock arrival time. These images are then used to reconstruct a volumetric approximation of the experimental perturbation. Analysis of the initial perturbations is performed, and then used as initial conditions in simulations using the hydrodynamics code ARES, developed at Lawrence Livermore National Laboratory (LLNL). Experiments are presented and comparisons are made with simulation results.

  3. Simultaneous 3D–2D image registration and C-arm calibration: Application to endovascular image-guided interventions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitrović, Uroš; Pernuš, Franjo; Likar, Boštjan

    Purpose: Three-dimensional to two-dimensional (3D–2D) image registration is a key to fusion and simultaneous visualization of valuable information contained in 3D pre-interventional and 2D intra-interventional images with the final goal of image guidance of a procedure. In this paper, the authors focus on 3D–2D image registration within the context of intracranial endovascular image-guided interventions (EIGIs), where the 3D and 2D images are generally acquired with the same C-arm system. The accuracy and robustness of any 3D–2D registration method, to be used in a clinical setting, is influenced by (1) the method itself, (2) uncertainty of initial pose of the 3Dmore » image from which registration starts, (3) uncertainty of C-arm’s geometry and pose, and (4) the number of 2D intra-interventional images used for registration, which is generally one and at most two. The study of these influences requires rigorous and objective validation of any 3D–2D registration method against a highly accurate reference or “gold standard” registration, performed on clinical image datasets acquired in the context of the intervention. Methods: The registration process is split into two sequential, i.e., initial and final, registration stages. The initial stage is either machine-based or template matching. The latter aims to reduce possibly large in-plane translation errors by matching a projection of the 3D vessel model and 2D image. In the final registration stage, four state-of-the-art intrinsic image-based 3D–2D registration methods, which involve simultaneous refinement of rigid-body and C-arm parameters, are evaluated. For objective validation, the authors acquired an image database of 15 patients undergoing cerebral EIGI, for which accurate gold standard registrations were established by fiducial marker coregistration. Results: Based on target registration error, the obtained success rates of 3D to a single 2D image registration after initial machine-based and template matching and final registration involving C-arm calibration were 36%, 73%, and 93%, respectively, while registration accuracy of 0.59 mm was the best after final registration. By compensating in-plane translation errors by initial template matching, the success rates achieved after the final stage improved consistently for all methods, especially if C-arm calibration was performed simultaneously with the 3D–2D image registration. Conclusions: Because the tested methods perform simultaneous C-arm calibration and 3D–2D registration based solely on anatomical information, they have a high potential for automation and thus for an immediate integration into current interventional workflow. One of the authors’ main contributions is also comprehensive and representative validation performed under realistic conditions as encountered during cerebral EIGI.« less

  4. Manifold learning for automatically predicting articular cartilage morphology in the knee with data from the osteoarthritis initiative (OAI)

    NASA Astrophysics Data System (ADS)

    Donoghue, C.; Rao, A.; Bull, A. M. J.; Rueckert, D.

    2011-03-01

    Osteoarthritis (OA) is a degenerative, debilitating disease with a large socio-economic impact. This study looks to manifold learning as an automatic approach to harness the plethora of data provided by the Osteoarthritis Initiative (OAI). We construct several Laplacian Eigenmap embeddings of articular cartilage appearance from MR images of the knee using multiple MR sequences. A region of interest (ROI) defined as the weight bearing medial femur is automatically located in all images through non-rigid registration. A pairwise intensity based similarity measure is computed between all images, resulting in a fully connected graph, where each vertex represents an image and the weight of edges is the similarity measure. Spectral analysis is then applied to these pairwise similarities, which acts to reduce the dimensionality non-linearly and embeds these images in a manifold representation. In the manifold space, images that are close to each other are considered to be more "similar" than those far away. In the experiment presented here we use manifold learning to automatically predict the morphological changes in the articular cartilage by using the co-ordinates of the images in the manifold as independent variables for multiple linear regression. In the study presented here five manifolds are generated from five sequences of 390 distinct knees. We find statistically significant correlations (up to R2 = 0.75), between our predictors and the results presented in the literature.

  5. Nonunique and nonuniform mapping in few-body Coulomb-explosion imaging

    NASA Astrophysics Data System (ADS)

    Sayler, A. M.; Eckner, E.; McKenna, J.; Esry, B. D.; Carnes, K. D.; Ben-Itzhak, I.; Paulus, G. G.

    2018-03-01

    Much of our knowledge of molecular geometry and interaction dynamics comes from indirect measurements of the molecular fragments following breakup. This technique—Coulomb-explosion imaging (CEI), i.e., determining the initial molecular configuration of a system from the momenta of the resulting fragments using knowledge of the particle interactions—is one of the fundamental tools of molecular physics. Moreover, CEI has been a staple of molecular studies for decades. Here we show that one often cannot assign a unique initial configuration to the few-body breakup of a polyatomic molecule given the measurement of the resulting fragments' momenta. Specifically, multiple initial configurations can result in identical momenta for a molecule breaking into three or more parts. Further, the nonunique and nonuniform mapping from the initial configuration to the measured momenta also significantly complicates the determination of molecular alignment at the time of breakup.

  6. MRI of inflammatory spondyloarthropathy following traumatic cauda equina syndrome.

    PubMed

    Ginder, L M; Porter, N A; Subedi, N; Singh, J; Lalam, R K; Tins, B J; Tyrrell, P N M; Osman, A; Cassar-Pullicino, V N

    2015-03-01

    Spondyloarthropathy has been described radiographically in patients following paralysis from spinal cord trauma. Onset of these findings after cauda equina syndrome have not been reported previously. Furthermore, the magnetic resonance documentation of its early evolution has not been recorded. We report a case of early-onset spondyloarthropathy shown by magnetic resonance imaging (MRI) in a patient with cauda equina syndrome due to bilateral sacral insufficiency fractures. Unique case study review, one case. Review of the clinical case notes and imaging including initial and subsequent MR imaging. The initial MRI of the lumbosacral spine showed bilateral sacral insufficiency fractures with a kyphotic deformity. The vertebral bodies were normal on the initial computed tomography and MRI studies, which did not reveal pre-existing features of sacroiliitis. The second MRI performed 5 months later clearly showed spondylitis at multiple vertebral levels with partial resolution 18 months post injury. Spondyloarthropathy in patients with paralysis due to spinal cord injury is well documented in the English language literature, but until now this has not been demonstrated by MRI. It is a rare complication of traumatic cauda equina syndrome that commences soon after the traumatic event and can resolve spontaneously.

  7. Extreme multistability analysis of memristor-based chaotic system and its application in image decryption

    NASA Astrophysics Data System (ADS)

    Li, Chuang; Min, Fuhong; Jin, Qiusen; Ma, Hanyuan

    2017-12-01

    An active charge-controlled memristive Chua's circuit is implemented, and its basic properties are analyzed. Firstly, with the system trajectory starting from an equilibrium point, the dynamic behavior of multiple coexisting attractors depending on the memristor initial value and the system parameter is studied, which shows the coexisting behaviors of point, period, chaos, and quasic-period. Secondly, with the system motion starting from a non-equilibrium point, the dynamics of extreme multistability in a wide initial value domain are easily conformed by new analytical methods. Furthermore, the simulation results indicate that some strange chaotic attractors like multi-wing type and multi-scroll type are observed when the observed signals are extended from voltage and current to power and energy, respectively. Specially, when different initial conditions are taken, the coexisting strange chaotic attractors between the power and energy signals are exhibited. Finally, the chaotic sequences of the new system are used for encrypting color image to protect image information security. The encryption performance is analyzed by statistic histogram, correlation, key spaces and key sensitivity. Simulation results show that the new memristive chaotic system has high security in color image encryption.

  8. Neural Correlates of Top-Down Letter Processing

    ERIC Educational Resources Information Center

    Liu, Jiangang; Li, Jun; Zhang, Hongchuan; Rieth, Cory A.; Huber, David E.; Li, Wu; Lee, Kang; Tian, Jie

    2010-01-01

    This fMRI study investigated top-down letter processing with an illusory letter detection task. Participants responded whether one of a number of different possible letters was present in a very noisy image. After initial training that became increasingly difficult, they continued to detect letters even though the images consisted of pure noise,…

  9. A device to measure the effects of strong magnetic fields on the image resolution of PET scanners

    NASA Astrophysics Data System (ADS)

    Burdette, D.; Albani, D.; Chesi, E.; Clinthorne, N. H.; Cochran, E.; Honscheid, K.; Huh, S. S.; Kagan, H.; Knopp, M.; Lacasta, C.; Mikuz, M.; Schmalbrock, P.; Studen, A.; Weilhammer, P.

    2009-10-01

    Very high resolution images can be achieved in small animal PET systems utilizing solid state silicon pad detectors. As these systems approach sub-millimeter resolutions, the range of the positron is becoming the dominant contribution to image blur. The size of the positron range effect depends on the initial positron energy and hence the radioactive tracer used. For higher energy positron emitters, such as Ga68 and Tc94m, which are gaining importance in small animal studies, the width of the annihilation point distribution dominates the spatial resolution. This positron range effect can be reduced by embedding the field of view of the PET scanner in a strong magnetic field. In order to confirm this effect experimentally, we developed a high resolution PET instrument based on silicon pad detectors that can operate in a 7 T magnetic field. In this paper, we describe the instrument and present initial results of a study of the effects of magnetic fields up to 7 T on PET image resolution for Na22 and Ga68 point sources.

  10. Investigating the efficacy of attention bias modification in reducing high spider fear: The role of individual differences in initial bias

    PubMed Central

    Fox, Elaine; Zougkou, Konstantina; Ashwin, Chris; Cahill, Shanna

    2015-01-01

    Background and objectives Attention Bias Modification (ABM) targets attention bias (AB) towards threat and is a potential therapeutic intervention for anxiety. The current study investigated whether initial AB (towards or away from spider images) influenced the effectiveness of ABM in spider fear. Methods AB was assessed with an attentional probe task consisting of spider and neutral images presented simultaneously followed by a probe in spider congruent or spider incongruent locations. Response time (RT) differences between spider and neutral trials > 25 ms was considered ‘Bias Toward’ threat. RT difference < - 25 ms was considered ‘Bias Away’ from threat, and a difference between −25 ms and +25 ms was considered ‘No Bias’. Participants were categorized into Initial Bias groups using pre-ABM AB scores calculated at the end of the study. 66 participants' (Bias Toward n = 27, Bias Away n = 18, No Bias n = 21) were randomly assigned to ABM-active training designed to reduce or eliminate a bias toward threat and 61 (Bias Toward n = 17, Bias Away n = 18, No Bias n = 26) to ABM-control. Results ABM-active had the largest impact on those demonstrating an initial Bias Towards spider images in terms of changing AB and reducing Spider Fear Vulnerability, with the Bias Away group experiencing least benefit from ABM. However, all Initial Bias groups benefited equally from active ABM in a Stress Task. Limitations Participants were high spider fearful but not formally diagnosed with a specific phobia. Therefore, results should be confirmed within a clinical population. Conclusions Individual differences in Initial Bias may be an important determinant of ABM efficacy. PMID:26060177

  11. 3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models

    PubMed Central

    Dhou, Salam; Hurwitz, Martina; Mishra, Pankaj; Cai, Weixing; Rottmann, Joerg; Li, Ruijiang; Williams, Christopher; Wagar, Matthew; Berbeco, Ross; Ionascu, Dan; Lewis, John H.

    2015-01-01

    3D fluoroscopic images represent volumetric patient anatomy during treatment with high spatial and temporal resolution. 3D fluoroscopic images estimated using motion models built using 4DCT images, taken days or weeks prior to treatment, do not reliably represent patient anatomy during treatment. In this study we develop and perform initial evaluation of techniques to develop patient-specific motion models from 4D cone-beam CT (4DCBCT) images, taken immediately before treatment, and use these models to estimate 3D fluoroscopic images based on 2D kV projections captured during treatment. We evaluate the accuracy of 3D fluoroscopic images by comparing to ground truth digital and physical phantom images. The performance of 4DCBCT- and 4DCT- based motion models are compared in simulated clinical situations representing tumor baseline shift or initial patient positioning errors. The results of this study demonstrate the ability for 4DCBCT imaging to generate motion models that can account for changes that cannot be accounted for with 4DCT-based motion models. When simulating tumor baseline shift and patient positioning errors of up to 5 mm, the average tumor localization error and the 95th percentile error in six datasets were 1.20 and 2.2 mm, respectively, for 4DCBCT-based motion models. 4DCT-based motion models applied to the same six datasets resulted in average tumor localization error and the 95th percentile error of 4.18 and 5.4 mm, respectively. Analysis of voxel-wise intensity differences was also conducted for all experiments. In summary, this study demonstrates the feasibility of 4DCBCT-based 3D fluoroscopic image generation in digital and physical phantoms, and shows the potential advantage of 4DCBCT-based 3D fluoroscopic image estimation when there are changes in anatomy between the time of 4DCT imaging and the time of treatment delivery. PMID:25905722

  12. Flash trajectory imaging of target 3D motion

    NASA Astrophysics Data System (ADS)

    Wang, Xinwei; Zhou, Yan; Fan, Songtao; He, Jun; Liu, Yuliang

    2011-03-01

    We present a flash trajectory imaging technique which can directly obtain target trajectory and realize non-contact measurement of motion parameters by range-gated imaging and time delay integration. Range-gated imaging gives the range of targets and realizes silhouette detection which can directly extract targets from complex background and decrease the complexity of moving target image processing. Time delay integration increases information of one single frame of image so that one can directly gain the moving trajectory. In this paper, we have studied the algorithm about flash trajectory imaging and performed initial experiments which successfully obtained the trajectory of a falling badminton. Our research demonstrates that flash trajectory imaging is an effective approach to imaging target trajectory and can give motion parameters of moving targets.

  13. Tracking tumor boundary in MV-EPID images without implanted markers: A feasibility study.

    PubMed

    Zhang, Xiaoyong; Homma, Noriyasu; Ichiji, Kei; Takai, Yoshihiro; Yoshizawa, Makoto

    2015-05-01

    To develop a markerless tracking algorithm to track the tumor boundary in megavoltage (MV)-electronic portal imaging device (EPID) images for image-guided radiation therapy. A level set method (LSM)-based algorithm is developed to track tumor boundary in EPID image sequences. Given an EPID image sequence, an initial curve is manually specified in the first frame. Driven by a region-scalable energy fitting function, the initial curve automatically evolves toward the tumor boundary and stops on the desired boundary while the energy function reaches its minimum. For the subsequent frames, the tracking algorithm updates the initial curve by using the tracking result in the previous frame and reuses the LSM to detect the tumor boundary in the subsequent frame so that the tracking processing can be continued without user intervention. The tracking algorithm is tested on three image datasets, including a 4-D phantom EPID image sequence, four digitally deformable phantom image sequences with different noise levels, and four clinical EPID image sequences acquired in lung cancer treatment. The tracking accuracy is evaluated based on two metrics: centroid localization error (CLE) and volume overlap index (VOI) between the tracking result and the ground truth. For the 4-D phantom image sequence, the CLE is 0.23 ± 0.20 mm, and VOI is 95.6% ± 0.2%. For the digital phantom image sequences, the total CLE and VOI are 0.11 ± 0.08 mm and 96.7% ± 0.7%, respectively. In addition, for the clinical EPID image sequences, the proposed algorithm achieves 0.32 ± 0.77 mm in the CLE and 72.1% ± 5.5% in the VOI. These results demonstrate the effectiveness of the authors' proposed method both in tumor localization and boundary tracking in EPID images. In addition, compared with two existing tracking algorithms, the proposed method achieves a higher accuracy in tumor localization. In this paper, the authors presented a feasibility study of tracking tumor boundary in EPID images by using a LSM-based algorithm. Experimental results conducted on phantom and clinical EPID images demonstrated the effectiveness of the tracking algorithm for visible tumor target. Compared with previous tracking methods, the authors' algorithm has the potential to improve the tracking accuracy in radiation therapy. In addition, real-time tumor boundary information within the irradiation field will be potentially useful for further applications, such as adaptive beam delivery, dose evaluation.

  14. Tracking tumor boundary in MV-EPID images without implanted markers: A feasibility study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Xiaoyong, E-mail: xiaoyong@ieee.org; Homma, Noriyasu, E-mail: homma@ieee.org; Ichiji, Kei, E-mail: ichiji@yoshizawa.ecei.tohoku.ac.jp

    2015-05-15

    Purpose: To develop a markerless tracking algorithm to track the tumor boundary in megavoltage (MV)-electronic portal imaging device (EPID) images for image-guided radiation therapy. Methods: A level set method (LSM)-based algorithm is developed to track tumor boundary in EPID image sequences. Given an EPID image sequence, an initial curve is manually specified in the first frame. Driven by a region-scalable energy fitting function, the initial curve automatically evolves toward the tumor boundary and stops on the desired boundary while the energy function reaches its minimum. For the subsequent frames, the tracking algorithm updates the initial curve by using the trackingmore » result in the previous frame and reuses the LSM to detect the tumor boundary in the subsequent frame so that the tracking processing can be continued without user intervention. The tracking algorithm is tested on three image datasets, including a 4-D phantom EPID image sequence, four digitally deformable phantom image sequences with different noise levels, and four clinical EPID image sequences acquired in lung cancer treatment. The tracking accuracy is evaluated based on two metrics: centroid localization error (CLE) and volume overlap index (VOI) between the tracking result and the ground truth. Results: For the 4-D phantom image sequence, the CLE is 0.23 ± 0.20 mm, and VOI is 95.6% ± 0.2%. For the digital phantom image sequences, the total CLE and VOI are 0.11 ± 0.08 mm and 96.7% ± 0.7%, respectively. In addition, for the clinical EPID image sequences, the proposed algorithm achieves 0.32 ± 0.77 mm in the CLE and 72.1% ± 5.5% in the VOI. These results demonstrate the effectiveness of the authors’ proposed method both in tumor localization and boundary tracking in EPID images. In addition, compared with two existing tracking algorithms, the proposed method achieves a higher accuracy in tumor localization. Conclusions: In this paper, the authors presented a feasibility study of tracking tumor boundary in EPID images by using a LSM-based algorithm. Experimental results conducted on phantom and clinical EPID images demonstrated the effectiveness of the tracking algorithm for visible tumor target. Compared with previous tracking methods, the authors’ algorithm has the potential to improve the tracking accuracy in radiation therapy. In addition, real-time tumor boundary information within the irradiation field will be potentially useful for further applications, such as adaptive beam delivery, dose evaluation.« less

  15. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the canine heart.

    PubMed

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2012-01-01

    Single-beat imaging of myocardial activation promises to aid in both cardiovascular research and clinical medicine. In the present study we validate a three-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of simultaneous 3D intracardiac mapping to assess its capability to localize endocardial and epicardial initiation sites and image global activation sequences during pacing and ventricular tachycardia (VT) in the canine heart. Body surface potentials were measured simultaneously with bipolar electrical recordings in a closed-chest condition in healthy canines. Computed tomography images were obtained after the mapping study to construct realistic geometry models. Data analysis was performed on paced rhythms and VTs induced by norepinephrine (NE). The noninvasively reconstructed activation sequence was in good agreement with the simultaneous measurements from 3D cardiac mapping with a correlation coefficient of 0.74 ± 0.06, a relative error of 0.29 ± 0.05, and a root mean square error of 9 ± 3 ms averaged over 460 paced beats and 96 ectopic beats including premature ventricular complexes, couplets, and nonsustained monomorphic VTs and polymorphic VTs. Endocardial and epicardial origins of paced beats were successfully predicted in 72% and 86% of cases, respectively, during left ventricular pacing. The NE-induced ectopic beats initiated in the subendocardium by a focal mechanism. Sites of initial activation were estimated to be ∼7 mm from the measured initiation sites for both the paced beats and ectopic beats. For the polymorphic VTs, beat-to-beat dynamic shifts of initiation site and activation pattern were characterized by the reconstruction. The present results suggest that 3DCEI can noninvasively image the 3D activation sequence and localize the origin of activation of paced beats and NE-induced VTs in the canine heart with good accuracy. This 3DCEI technique offers the potential to aid interventional therapeutic procedures for treating ventricular arrhythmias arising from epicardial or endocardial sites and to noninvasively assess the mechanisms of these arrhythmias.

  16. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the canine heart

    PubMed Central

    Han, Chengzong; Pogwizd, Steven M.; Killingsworth, Cheryl R.

    2012-01-01

    Single-beat imaging of myocardial activation promises to aid in both cardiovascular research and clinical medicine. In the present study we validate a three-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of simultaneous 3D intracardiac mapping to assess its capability to localize endocardial and epicardial initiation sites and image global activation sequences during pacing and ventricular tachycardia (VT) in the canine heart. Body surface potentials were measured simultaneously with bipolar electrical recordings in a closed-chest condition in healthy canines. Computed tomography images were obtained after the mapping study to construct realistic geometry models. Data analysis was performed on paced rhythms and VTs induced by norepinephrine (NE). The noninvasively reconstructed activation sequence was in good agreement with the simultaneous measurements from 3D cardiac mapping with a correlation coefficient of 0.74 ± 0.06, a relative error of 0.29 ± 0.05, and a root mean square error of 9 ± 3 ms averaged over 460 paced beats and 96 ectopic beats including premature ventricular complexes, couplets, and nonsustained monomorphic VTs and polymorphic VTs. Endocardial and epicardial origins of paced beats were successfully predicted in 72% and 86% of cases, respectively, during left ventricular pacing. The NE-induced ectopic beats initiated in the subendocardium by a focal mechanism. Sites of initial activation were estimated to be ∼7 mm from the measured initiation sites for both the paced beats and ectopic beats. For the polymorphic VTs, beat-to-beat dynamic shifts of initiation site and activation pattern were characterized by the reconstruction. The present results suggest that 3DCEI can noninvasively image the 3D activation sequence and localize the origin of activation of paced beats and NE-induced VTs in the canine heart with good accuracy. This 3DCEI technique offers the potential to aid interventional therapeutic procedures for treating ventricular arrhythmias arising from epicardial or endocardial sites and to noninvasively assess the mechanisms of these arrhythmias. PMID:21984548

  17. A platform for studying the Rayleigh-Taylor and Richtmyer-Meshkov instabilities in a planar geometry at high energy density at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Nagel, S. R.; Raman, K. S.; Huntington, C. M.; MacLaren, S. A.; Wang, P.; Barrios, M. A.; Baumann, T.; Bender, J. D.; Benedetti, L. R.; Doane, D. M.; Felker, S.; Fitzsimmons, P.; Flippo, K. A.; Holder, J. P.; Kaczala, D. N.; Perry, T. S.; Seugling, R. M.; Savage, L.; Zhou, Y.

    2017-07-01

    A new experimental platform has been developed at the National Ignition Facility (NIF) for studying the Rayleigh-Taylor (RT) and Richtmyer-Meshkov (RM) instabilities in a planar geometry at high-energy-densities. The platform uses 60 beams of the NIF laser to drive an initially solid shock tube containing a pre-machined interface between dense and light materials. The strong shock turns the initially solid target into a plasma and the material boundary into a fluid interface with the imprinted initial condition. The interface evolves by action of the RT and RM instabilities, and the growth is imaged with backlit x-ray radiography. We present our first data involving sinusoidal interface perturbations driven from the heavy side to the light side. Late-time radiographic images show the initial conditions reaching the deeply nonlinear regime, and an evolution of fine structure consistent with a transition to turbulence. We show preliminary comparisons with post-shot numerical simulations and discuss the implications for future campaigns.

  18. Noise Power Spectrum in PROPELLER MR Imaging.

    PubMed

    Ichinoseki, Yuki; Nagasaka, Tatsuo; Miyamoto, Kota; Tamura, Hajime; Mori, Issei; Machida, Yoshio

    2015-01-01

    The noise power spectrum (NPS), an index for noise evaluation, represents the frequency characteristics of image noise. We measured the NPS in PROPELLER (Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction) magnetic resonance (MR) imaging, a nonuniform data sampling technique, as an initial study for practical MR image evaluation using the NPS. The 2-dimensional (2D) NPS reflected the k-space sampling density and showed agreement with the shape of the k-space trajectory as expected theoretically. Additionally, the 2D NPS allowed visualization of a part of the image reconstruction process, such as filtering and motion correction.

  19. Fully automatic segmentation of the femur from 3D-CT images using primitive shape recognition and statistical shape models.

    PubMed

    Ben Younes, Lassad; Nakajima, Yoshikazu; Saito, Toki

    2014-03-01

    Femur segmentation is well established and widely used in computer-assisted orthopedic surgery. However, most of the robust segmentation methods such as statistical shape models (SSM) require human intervention to provide an initial position for the SSM. In this paper, we propose to overcome this problem and provide a fully automatic femur segmentation method for CT images based on primitive shape recognition and SSM. Femur segmentation in CT scans was performed using primitive shape recognition based on a robust algorithm such as the Hough transform and RANdom SAmple Consensus. The proposed method is divided into 3 steps: (1) detection of the femoral head as sphere and the femoral shaft as cylinder in the SSM and the CT images, (2) rigid registration between primitives of SSM and CT image to initialize the SSM into the CT image, and (3) fitting of the SSM to the CT image edge using an affine transformation followed by a nonlinear fitting. The automated method provided good results even with a high number of outliers. The difference of segmentation error between the proposed automatic initialization method and a manual initialization method is less than 1 mm. The proposed method detects primitive shape position to initialize the SSM into the target image. Based on primitive shapes, this method overcomes the problem of inter-patient variability. Moreover, the results demonstrate that our method of primitive shape recognition can be used for 3D SSM initialization to achieve fully automatic segmentation of the femur.

  20. American Thyroid Association statement on preoperative imaging for thyroid cancer surgery.

    PubMed

    Yeh, Michael W; Bauer, Andrew J; Bernet, Victor A; Ferris, Robert L; Loevner, Laurie A; Mandel, Susan J; Orloff, Lisa A; Randolph, Gregory W; Steward, David L

    2015-01-01

    The success of surgery for thyroid cancer hinges on thorough and accurate preoperative imaging, which enables complete clearance of the primary tumor and affected lymph node compartments. This working group was charged by the Surgical Affairs Committee of the American Thyroid Association to examine the available literature and to review the most appropriate imaging studies for the planning of initial and revision surgery for thyroid cancer. Ultrasound remains the most important imaging modality in the evaluation of thyroid cancer, and should be used routinely to assess both the primary tumor and all associated cervical lymph node basins preoperatively. Positive lymph nodes may be distinguished from normal nodes based upon size, shape, echogenicity, hypervascularity, loss of hilar architecture, and the presence of calcifications. Ultrasound-guided fine-needle aspiration of suspicious lymph nodes may be useful in guiding the extent of surgery. Cross-sectional imaging (computed tomography with contrast or magnetic resonance imaging) may be considered in select circumstances to better characterize tumor invasion and bulky, inferiorly located, or posteriorly located lymph nodes, or when ultrasound expertise is not available. The above recommendations are applicable to both initial and revision surgery. Functional imaging with positron emission tomography (PET) or PET-CT may be helpful in cases of recurrent cancer with positive tumor markers and negative anatomic imaging.

  1. American Thyroid Association Statement on Preoperative Imaging for Thyroid Cancer Surgery

    PubMed Central

    Bauer, Andrew J.; Bernet, Victor A.; Ferris, Robert L.; Loevner, Laurie A.; Mandel, Susan J.; Orloff, Lisa A.; Randolph, Gregory W.; Steward, David L.

    2015-01-01

    Background: The success of surgery for thyroid cancer hinges on thorough and accurate preoperative imaging, which enables complete clearance of the primary tumor and affected lymph node compartments. This working group was charged by the Surgical Affairs Committee of the American Thyroid Association to examine the available literature and to review the most appropriate imaging studies for the planning of initial and revision surgery for thyroid cancer. Summary: Ultrasound remains the most important imaging modality in the evaluation of thyroid cancer, and should be used routinely to assess both the primary tumor and all associated cervical lymph node basins preoperatively. Positive lymph nodes may be distinguished from normal nodes based upon size, shape, echogenicity, hypervascularity, loss of hilar architecture, and the presence of calcifications. Ultrasound-guided fine-needle aspiration of suspicious lymph nodes may be useful in guiding the extent of surgery. Cross-sectional imaging (computed tomography with contrast or magnetic resonance imaging) may be considered in select circumstances to better characterize tumor invasion and bulky, inferiorly located, or posteriorly located lymph nodes, or when ultrasound expertise is not available. The above recommendations are applicable to both initial and revision surgery. Functional imaging with positron emission tomography (PET) or PET-CT may be helpful in cases of recurrent cancer with positive tumor markers and negative anatomic imaging. PMID:25188202

  2. Development of an improved CAD scheme for automated detection of lung nodules in digital chest images.

    PubMed

    Xu, X W; Doi, K; Kobayashi, T; MacMahon, H; Giger, M L

    1997-09-01

    Lung cancer is the leading cause of cancer deaths in men and women in the United States, with a 5-year survival rate of only about 13%. However, this survival rate can be improved to 47% if the disease is diagnosed and treated at an early stage. In this study, we developed an improved computer-aided diagnosis (CAD) scheme for the automated detection of lung nodules in digital chest images to assist radiologists, who could miss up to 30% of the actually positive cases in their daily practice. Two hundred PA chest radiographs, 100 normals and 100 abnormals, were used as the database for our study. The presence of nodules in the 100 abnormal cases was confirmed by two experienced radiologists on the basis of CT scans or radiographic follow-up. In our CAD scheme, nodule candidates were selected initially by multiple gray-level thresholding of the difference image (which corresponds to the subtraction of a signal-enhanced image and a signal-suppressed image) and then classified into six groups. A large number of false positives were eliminated by adaptive rule-based tests and an artificial neural network (ANN). The CAD scheme achieved, on average, a sensitivity of 70% with 1.7 false positives per chest image, a performance which was substantially better as compared with other studies. The CPU time for the processing of one chest image was about 20 seconds on an IBM RISC/6000 Powerstation 590. We believe that the CAD scheme with the current performance is ready for initial clinical evaluation.

  3. Near-IR Image-Guided Laser Ablation of Demineralization on Tooth Occlusal Surfaces

    PubMed Central

    Tom, Henry; Chan, Kenneth H.; Darling, Cynthia L.; Fried, Daniel

    2016-01-01

    Introduction Studies have shown that reflectance images at near-IR wavelengths coincident with higher water absorption are well-suited for image-guided laser ablation of carious lesions since the contrast between sound and demineralized enamel is extremely high and interference from stains is minimized. The objective of this study was to demonstrate that near-IR reflectance images taken at a wavelength range of 1,500–1,700 nm can be used to guide a 9.3 μm CO2 laser for the selective ablation of early demineralization on tooth occlusal surfaces. Methods The occlusal surfaces of ten sound human molars were used in this in vitro study. Shallow simulated caries lesions with random patterns and varying depth and position were produced on tooth occlusal surfaces. Sequential near-IR reflectance images at 1,500–1,700 nm were used to guide the laser for the selective removal of the demineralized enamel. Digital microscopy and polarization sensitive optical coherence tomography (PS-OCT) were used to assess selectivity. Results Images taken before and after lesion removal suggest that the demineralized areas were removed with high selectivity. Although the estimated volume of tissue ablated was typically higher than the initial lesion volume measured with PS-OCT, the volume of enamel removed by the laser correlated well with the initial lesion volume. Conclusion Sequential near-IR reflectance images at 1,500–1,700 nm can be used to guide a 9.3 μm CO2 laser for the selective ablation of early demineralization on tooth occlusal surfaces. PMID:26763111

  4. Results of a prospective clinical study on the diagnostic performance of standard magnetic resonance imaging in comparison to a combination of 3T MRI and additional CT imaging in Kienböck's disease.

    PubMed

    Stahl, Stephane; Hentschel, Pascal; Ketelsen, Dominik; Grosse, Ulrich; Held, Manuel; Wahler, Theodora; Syha, Roland; Schaller, Hans-Eberhard; Nikolaou, Konstantin; Grözinger, Gerd

    2017-05-01

    This prospective clinical study examined standard wrist magnetic resonance imaging (MRI) examinations and the incremental value of computed tomography (CT) in the diagnosis of Kienböck's disease (KD) with regard to reliability and precision in the different diagnostic steps during diagnostic work-up. Sixty-four consecutive patients referred between January 2009 and January 2014 with positive initial suspicion of KD according to external standard wrist MRI were prospectively included (step one). Institutional review board approval was obtained. Clinical examination by two handsurgeons were followed by wrist radiographs (step two), ultrathin-section CT, and 3T contrast-enhanced MRI (step three). Final diagnosis was established in a consensus conference involving all examiners and all examinations results available from step three. In 12/64 patients, initial suspicion was discarded at step two and in 34/64 patients, the initial suspicion of KD was finally discarded at step three. The final external MRI positive predictive value was 47%. The most common differential diagnoses at step three were intraosseous cysts (n=15), lunate pseudarthrosis (n=13), and ulnar impaction syndrome (n=5). A correlation between radiograph-based diagnoses (step two) with final diagnosis (step three) showed that initial suspicion of stage I KD had the lowest sensitivity for correct diagnosis (2/11). Technical factors associated with a false positive external MRI KD diagnosis were not found. Standard wrist MRI should be complemented with thin-section CT, and interdisciplinary interpretation of images and clinical data, to increase diagnostic accuracy in patients with suspected KD. Copyright © 2017. Published by Elsevier B.V.

  5. Role for imaging in spondyloarthritis.

    PubMed

    Ran, Jun; Morelli, John N; Xie, Ruyi; Zhang, Xiaoli; Liang, Xiaoqing; Liu, Xuanlin; Li, Xiaoming

    2017-09-01

    Despite major progress in the imaging diagnosis of spondyloarthritis (SpA), the relative advantages of various available imaging techniques remain unclear. The aim of this study is to assess the current use of imaging in the diagnosis of SpA and to provide suitable recommendations for the use of imaging as an outcome measure as defined in the Assessment in SpondyloArthritis international Society (ASAS) criteria. A systematic literature search regarding imaging in SpA was performed. Articles were assessed by two reviewers to identify and summarized key information pertaining to imaging in SpA. The search identified 180 relevant articles. Conventional radiography (CR) (17 articles), ultrasound (US) (26 articles), conventional computed tomography (CT) (13 articles), spectral computed tomography (spectral CT) (2 articles), bone scintigraphy (24 articles), and magnetic resonance imaging (MRI) were assessed (98 articles). Sacroiliitis and enthesitis were the major imaging findings in SpA. Multiple studies assessed the feasibility, validity, or differences among imaging modalities for the diagnosis of SpA; however, comprehensive assessments were not available due to a paucity of prospective imaging studies. CR is a widely available, inexpensive initial approach to evaluate patients with suspected SpA. CT enables assessment of structural changes from chronic sacroiliitis including bony erosions, subchondral sclerosis, joint space narrowing, and ankyloses; however, both CR and CT modalities are insensitive for demonstrating early enthesitis and sacroiliitis in SpA. US mainly identifies appendicular enthesitis but is more limited with respect to the sacroiliac joints. Bone scintigraphy can identify sacroiliac joint lesions and semi-quantitatively assess active sacroiliitis. MRI optimally evaluates not only early enthesitis and sacroiliitis of SpA but also chronic structural changes to the sacroiliac joints. More than one modality may be required for diagnostic and assessment of SpA depending upon disease characteristics and evolution. CR is a suitable initial examination while MRI is able to detect both early and late changes of SpA. A combination of CR and MRI is recommended for the diagnosis and assessment of SpA.

  6. Dynamic optical imaging of vascular and metabolic reactivity in rheumatoid joints.

    PubMed

    Lasker, Joseph M; Fong, Christopher J; Ginat, Daniel T; Dwyer, Edward; Hielscher, Andreas H

    2007-01-01

    Dynamic optical imaging is increasingly applied to clinically relevant areas such as brain and cancer imaging. In this approach, some external stimulus is applied and changes in relevant physiological parameters (e.g., oxy- or deoxyhemoglobin concentrations) are determined. The advantage of this approach is that the prestimulus state can be used as a reference or baseline against which the changes can be calibrated. Here we present the first application of this method to the problem of characterizing joint diseases, especially effects of rheumatoid arthritis (RA) in the proximal interphalangeal finger joints. Using a dual-wavelength tomographic imaging system together with previously implemented model-based iterative image reconstruction schemes, we have performed initial dynamic imaging case studies on a limited number of healthy volunteers and patients diagnosed with RA. Focusing on three cases studies, we illustrated our major finds. These studies support our hypothesis that differences in the vascular reactivity exist between affected and unaffected joints.

  7. Nuclear medicine and imaging research. Quantitative studies in radiopharmaceutical science. Comprehensive progress report, January 1, 1983-June 30, 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beck, R.N.; Cooper, M.D.

    1985-09-01

    This comprehensive report outlines the progress made during the past three years in the areas described below. In all instances, initial studies have been carried out and the technical feasibility of carrying through each study has been demonstrated. The studies described include development of cesium-130 and bromine-75 radioisotope generators, the feasibility of using rubidium-82 as a myocardial imaging agent, and radiochemical preparation of C-11 deoxyglucose. 28 refs. (DT)

  8. Dynamic contrast-enhanced breast MR imaging in men: preliminary results.

    PubMed

    Morakkabati-Spitz, Nuschin; Schild, Hans H; Leutner, Claudia C; von Falkenhausen, Marcus; Lutterbey, Götz; Kuhl, Christiane K

    2006-02-01

    To prospectively evaluate whether the descriptors of lesion features and the diagnostic criteria that have been established for breast magnetic resonance (MR) imaging in female patients may be used for differential diagnosis with breast MR imaging in male patients as well. The study design was approved by the institutional review board; all patients gave informed consent. The Institutional Review Board and informed consent information applied to the prospective and any retrospective component of the study. Seventeen consecutive male patients (mean age, 53 years +/- 14) were referred for imaging of a palpable breast mass. In addition to mammography and high-frequency breast ultrasonography, patients underwent dynamic breast MR imaging in a prone position with a dedicated double-breast surface coil. The standardized protocol consisted of a T2-weighted turbo spin-echo sequence followed by a dynamic series. Findings were recorded by using the terminology and descriptors and by evaluating the diagnostic criteria (related to morphology and enhancement kinetics) that have been developed for breast MR imaging in female patients. Validation was achieved at biopsy (nine patients) or follow-up with clinical examination and conventional imaging (eight patients). Because of the small size of the patient cohort, statistical significance was not tested. A total of 24 breast abnormalities were diagnosed. Three patients had invasive breast cancer (five tumors), 11 had gynecomastia (six unilateral, five bilateral), two had pseudogynecomastia, and one had a benign solid tumor (angiolipoma). All malignant tumors appeared as irregular masses with heterogeneous internal architecture or rim enhancement and showed rapid initial enhancement (mean value, 137% +/- 23) followed by a washout time course (Breast Imaging Reporting and Data System [BI-RADS] category 5). Diffuse and nodular gynecomastia showed slow initial and persistent enhancement with normal-appearing parenchymal architecture (BI-RADS category 2; 15 of 16 breasts in 10 of 11 patients). In one patient with biopsy-proved bilateral gynecomastia, an area with segmental enhancement was classified as suspicious for ductal carcinoma in situ. Pseudogynecomastia did not enhance at all. The angiolipoma showed benign morphologic features and slow initial and persistent enhancement (BI-RADS category 2). In the small study cohort, the MR imaging features of benign breast diseases and breast cancers in male patients seemed to be comparable to those seen in female patients. (c) RSNA, 2005

  9. Simulation Study of Effects of the Blind Deconvolution on Ultrasound Image

    NASA Astrophysics Data System (ADS)

    He, Xingwu; You, Junchen

    2018-03-01

    Ultrasonic image restoration is an essential subject in Medical Ultrasound Imaging. However, without enough and precise system knowledge, some traditional image restoration methods based on the system prior knowledge often fail to improve the image quality. In this paper, we use the simulated ultrasound image to find the effectiveness of the blind deconvolution method for ultrasound image restoration. Experimental results demonstrate that the blind deconvolution method can be applied to the ultrasound image restoration and achieve the satisfactory restoration results without the precise prior knowledge, compared with the traditional image restoration method. And with the inaccurate small initial PSF, the results shows blind deconvolution could improve the overall image quality of ultrasound images, like much better SNR and image resolution, and also show the time consumption of these methods. it has no significant increasing on GPU platform.

  10. [Initial diagnosis of Parkinson's disease - neuroradiological diagnosis].

    PubMed

    Orimo, Satoshi

    2013-01-01

    Brain MRI is essential for differentiating Parkinson's disease (PD) from other parkinsonian syndromes. The purpose of performing brain MRI is not to make a diagnosis of PD but is to exclude other parkinsonian syndromes. Recently, several new MRI techniques such as voxel based morphometry, relaxometry, magnetization transfer, spectroscopy, tractography, and functional MRI have been introduced in the diagnosis of PD. Neuromelanin imaging is one of the new techniques and can be useful to make an initial diagnosis of PD. MIBG myocardial scintigraphy is a sensitive imaging tool to differentiate PD from other parkinsonian syndromes and is one of the good tools to make an initial diagnosis of PD. Brain perfusion imaging is sometimes useful to make an initial diagnosis of PD, because reduced brain perfusion area can be detected before brain MRI detects morphological changes of the brain. Dopamine transporter imaging, not available in Japan, is a sensitive tool to detect very early parkinsonism and is useful to make an initial diagnosis of PD. However, it is difficult to differentiate PD from other parkinsonian syndromes.

  11. Improved tumor identification using dual tracer molecular imaging in fluorescence guided brain surgery

    NASA Astrophysics Data System (ADS)

    Xu, Xiaochun; Torres, Veronica; Straus, David; Brey, Eric M.; Byrne, Richard W.; Tichauer, Kenneth M.

    2015-03-01

    Brain tumors represent a leading cause of cancer death for people under the age of 40 and the probability complete surgical resection of brain tumors remains low owing to the invasive nature of these tumors and the consequences of damaging healthy brain tissue. Molecular imaging is an emerging approach that has the potential to improve the ability for surgeons to correctly discriminate between healthy and cancerous tissue; however, conventional molecular imaging approaches in brain suffer from significant background signal in healthy tissue or an inability target more invasive sections of the tumor. This work presents initial studies investigating the ability of novel dual-tracer molecular imaging strategies to be used to overcome the major limitations of conventional "single-tracer" molecular imaging. The approach is evaluated in simulations and in an in vivo mice study with animals inoculated orthotopically using fluorescent human glioma cells. An epidermal growth factor receptor (EGFR) targeted Affibody-fluorescent marker was employed as a targeted imaging agent, and the suitability of various FDA approved untargeted fluorescent tracers (e.g. fluorescein & indocyanine green) were evaluated in terms of their ability to account for nonspecific uptake and retention of the targeted imaging agent. Signal-to-background ratio was used to measure and compare the amount of reporter in the tissue between targeted and untargeted tracer. The initial findings suggest that FDA-approved fluorescent imaging agents are ill-suited to act as untargeted imaging agents for dual-tracer fluorescent guided brain surgery as they suffer from poor delivery to the healthy brain tissue and therefore cannot be used to identify nonspecific vs. specific uptake of the targeted imaging agent where current surgery is most limited.

  12. Managing job seekers' organizational image beliefs: the role of media richness and media credibility.

    PubMed

    Cable, Daniel M; Yu, Kang Yang Trevor

    2006-07-01

    In this article, the authors assessed job seekers' organizational image beliefs before and after they experienced 3 recruitment media. The authors examined whether perceptions of media richness and credibility were related to improvements in the correspondence between job seekers' image beliefs and firms' projected images. Both media richness and credibility perceptions were associated with correspondence between job seekers' image beliefs and firms' projected images. However, results revealed that richness and credibility perceptions were likely to enhance job seekers' initial beliefs about firms' images when their beliefs were positive but did not diminish job seekers' beliefs about firms' images when their initial impressions were too positive. ((c) 2006 APA, all rights reserved).

  13. The ELISE II Project: A Digital Image Library for Europe.

    ERIC Educational Resources Information Center

    Strunz, Bob; Waters, Mairead

    This paper describes the progress made under the ELISE II electronic image library project from a technical standpoint. The ELISE II project is a European-wide initiative that aims to provide a comprehensive electronic image library service for Europe. It is funded under the European Commission, DG XIII-E, Telematics for Libraries Initiative. The…

  14. Children's and adults' memory for emotional pictures: examining age-related patterns using the Developmental Affective Photo System.

    PubMed

    Cordon, Ingrid M; Melinder, Annika M D; Goodman, Gail S; Edelstein, Robin S

    2013-02-01

    Two studies were conducted to examine theoretical questions about children's and adults' memory for emotional visual stimuli. In Study 1, 7- to 9-year-olds and adults (N=172) participated in the initial creation of the Developmental Affective Photo System (DAPS). Ratings of emotional valence, arousal, and complexity were obtained. In Study 2, DAPS pictures were presented to 20 8- to 12-year-olds and 30 adults, followed by a recognition memory test. Children and adults recognized aversive images better than neutral images. Moreover, children and adults recognized high and moderate arousal images more accurately than low arousal images. Adults' memory for neutral images exceeded that of children, but there were no developmental differences in memory for aversive pictures. Theoretical and methodological implications are discussed. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Radiotherapy treatment planning: benefits of CT-MR image registration and fusion in tumor volume delineation.

    PubMed

    Djan, Igor; Petrović, Borislava; Erak, Marko; Nikolić, Ivan; Lucić, Silvija

    2013-08-01

    Development of imaging techniques, computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET), made great impact on radiotherapy treatment planning by improving the localization of target volumes. Improved localization allows better local control of tumor volumes, but also minimizes geographical misses. Mutual information is obtained by registration and fusion of images achieved manually or automatically. The aim of this study was to validate the CT-MRI image fusion method and compare delineation obtained by CT versus CT-MRI image fusion. The image fusion software (XIO CMS 4.50.0) was applied to delineate 16 patients. The patients were scanned on CT and MRI in the treatment position within an immobilization device before the initial treatment. The gross tumor volume (GTV) and clinical target volume (CTV) were delineated on CT alone and on CT+MRI images consecutively and image fusion was obtained. Image fusion showed that CTV delineated on a CT image study set is mainly inadequate for treatment planning, in comparison with CTV delineated on CT-MRI fused image study set. Fusion of different modalities enables the most accurate target volume delineation. This study shows that registration and image fusion allows precise target localization in terms of GTV and CTV and local disease control.

  16. Case of possible multiple system atrophy with a characteristic imaging finding of open bladder neck during storage phase as an initial sign.

    PubMed

    Zhang, Lu; Haga, Nobuhiro; Ogawa, Soichiro; Matsuoka, Kanako; Koguchi, Tomoyuki; Akaihata, Hidenori; Hata, Junya; Kataoka, Masao; Ishibashi, Kei; Kojima, Yoshiyuki

    2017-11-01

    Multiple system atrophy is a neurodegenerative disease that affects autonomic and motor systems. Patients with multiple system atrophy usually experience lower urinary tract symptoms, which sometimes appear as an initial symptom before the emergence of the generalized symptoms. An open bladder neck during the filling phase on video urodynamic study is one characteristic imaging finding after the diagnosis of multiple system atrophy, but has not previously been reported at an early phase of the disease. We report a case in which an open bladder neck was observed on several imaging modalities before generalized symptoms emerged. Because occult neurogenic bladder might exist in patients whose lower urinary tract symptoms are resistant to pharmacotherapy, we report this case to raise awareness of the importance of sufficient imaging evaluations. An open bladder neck might be an important imaging finding for diagnosing multiple system atrophy, irrespective of the presence of generalized symptoms. This finding could help avoid false diagnosis and unnecessary treatment. © 2017 The Japanese Urological Association.

  17. High-resolution axial MR imaging of tibial stress injuries

    PubMed Central

    2012-01-01

    Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries. PMID:22574840

  18. Remote sensing of a dynamic sub-arctic peatland reservoir using optical and synthetic aperture radar data

    NASA Astrophysics Data System (ADS)

    Larter, Jarod Lee

    Stephens Lake, Manitoba is an example of a peatland reservoir that has undergone physical changes related to mineral erosion and peatland disintegration processes since its initial impoundment. In this thesis I focused on the processes of peatland upheaval, transport, and disintegration as the primary drivers of dynamic change within the reservoir. The changes related to these processes are most frequent after initial reservoir impoundment and decline over time. They continue to occur over 35 years after initial flooding. I developed a remote sensing approach that employs both optical and microwave sensors for discriminating land (Le. floating peatlands, forested land, and barren land) from open water within the reservoir. High spatial resolution visible and near-infrared (VNIR) optical data obtained from the QuickBird satellite, and synthetic aperture radar (SAR) microwave data obtained from the RADARSAT-1 satellite were implemented. The approach was facilitated with a Geographic Information System (GIS) based validation map for the extraction of optical and SAR pixel data. Each sensor's extracted data set was first analyzed separately using univariate and multivariate statistical methods to determine the discriminant ability of each sensor. The initial analyses were followed by an integrated sensor approach; the development of an image classification model; and a change detection analysis. Results showed excellent (> 95%) classification accuracy using QuickBird satellite image data. Discrimination and classification of studied land cover classes using SAR image texture data resulted in lower overall classification accuracies (˜ 60%). SAR data classification accuracy improved to > 90% when classifying only land and water, demonstrating SAR's utility as a land and water mapping tool. An integrated sensor data approach showed no considerable improvement over the use of optical satellite image data alone. An image classification model was developed that could be used to map both detailed land cover classes and the land and water interface within the reservoir. Change detection analysis over a seven year period indicated that physical changes related to mineral erosion, peatland upheaval, transport, and disintegration, and operational water level variation continue to take place in the reservoir some 35 years after initial flooding. This thesis demonstrates the ability of optical and SAR satellite image remote sensing data sets to be used in an operational context for the routine discrimination of the land and water boundaries within a dynamic peatland reservoir. Future monitoring programs would benefit most from a complementary image acquisition program in which SAR images, known for their acquisition reliability under cloud cover, are acquired along with optical images given their ability to discriminate land cover classes in greater detail.

  19. Twin robotic x-ray system for 2D radiographic and 3D cone-beam CT imaging

    NASA Astrophysics Data System (ADS)

    Fieselmann, Andreas; Steinbrener, Jan; Jerebko, Anna K.; Voigt, Johannes M.; Scholz, Rosemarie; Ritschl, Ludwig; Mertelmeier, Thomas

    2016-03-01

    In this work, we provide an initial characterization of a novel twin robotic X-ray system. This system is equipped with two motor-driven telescopic arms carrying X-ray tube and flat-panel detector, respectively. 2D radiographs and fluoroscopic image sequences can be obtained from different viewing angles. Projection data for 3D cone-beam CT reconstruction can be acquired during simultaneous movement of the arms along dedicated scanning trajectories. We provide an initial evaluation of the 3D image quality based on phantom scans and clinical images. Furthermore, initial evaluation of patient dose is conducted. The results show that the system delivers high image quality for a range of medical applications. In particular, high spatial resolution enables adequate visualization of bone structures. This system allows 3D X-ray scanning of patients in standing and weight-bearing position. It could enable new 2D/3D imaging workflows in musculoskeletal imaging and improve diagnosis of musculoskeletal disorders.

  20. Contrast-enhanced [18F] fluorodeoxyglucose-positron emission tomography-computed tomography as an initial imaging modality in patients presenting with metastatic malignancy of undefined primary origin.

    PubMed

    Jain, Avani; Srivastava, Madhur Kumar; Pawaskar, Alok Suresh; Shelley, Simon; Elangovan, Indirani; Jain, Hasmukh; Pandey, Somnath; Kalal, Shilpa; Amalachandran, Jaykanth

    2015-01-01

    To evaluate the advantages of contrast enhanced F-18-fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-contrast enhanced CT [CECT]) when used as an initial imaging modality in patients presenting with metastatic malignancy of undefined primary origin (MUO). A total of 243 patients with fine needle aspiration cytology/biopsy proven MUO were included in this prospective study. Patients who were thoroughly evaluated for primary or primary tumor was detected by any other investigation were excluded from the analysis. Totally, 163 patients with pathological diagnosis of malignancy but no apparent sites of the primary tumor were finally selected for analysis. The site of probable primary malignancy suggested by PET-CECT was confirmed by biopsy/follow-up. PET-CECT suggested probable site of primary in 128/163 (78.52%) patients. In 30/35 remaining patients, primary tumor was not detected even after extensive work-up. In 5 patients, where PET-CECT was negative, primary was found on further extensive investigations or follow-up. The sensitivity, specificity, positive predictive value and negative predictive value of the study were 95.76%, 66.67%, 88.28% and 85.71% respectively. F-18 FDG PET-CECT aptly serves the purpose of initial imaging modality owing to high sensitivity, negative and positive predictive value. PET-CECT not only surveys the whole body for the primary malignancy but also stages the disease accurately. Use of contrast improves the diagnostic utility of modality as well as help in staging of the primary tumor. Although benefits of using PET-CECT as initial diagnostic modality are obvious from this study, there is a need for a larger study comparing conventional methods for diagnosing primary in patients with MUO versus PET-CECT.

  1. Improving TSA’s Public Image: Customer-Focused Initiatives to Encourage Public Trust and Confidence

    DTIC Science & Technology

    2013-12-01

    INITIATIVES TO ENCOURAGE PUBLIC TRUST AND CONFIDENCE Patricia S. Bierle Customer Support and Quality Improvement Manager, Transportation Security...PUBLIC IMAGE: CUSTOMER-FOCUSED INITIATIVES TO ENCOURAGE PUBLIC TRUST AND CONFIDENCE by Patricia S. Bierle December 2013 Thesis Co-Advisors...33 e . Government Leaders Impact Public Opinion ........................35 f. Aviation Stakeholders Also Impact

  2. Improved initial guess with semi-subpixel level accuracy in digital image correlation by feature-based method

    NASA Astrophysics Data System (ADS)

    Zhang, Yunlu; Yan, Lei; Liou, Frank

    2018-05-01

    The quality initial guess of deformation parameters in digital image correlation (DIC) has a serious impact on convergence, robustness, and efficiency of the following subpixel level searching stage. In this work, an improved feature-based initial guess (FB-IG) scheme is presented to provide initial guess for points of interest (POIs) inside a large region. Oriented FAST and Rotated BRIEF (ORB) features are semi-uniformly extracted from the region of interest (ROI) and matched to provide initial deformation information. False matched pairs are eliminated by the novel feature guided Gaussian mixture model (FG-GMM) point set registration algorithm, and nonuniform deformation parameters of the versatile reproducing kernel Hilbert space (RKHS) function are calculated simultaneously. Validations on simulated images and real-world mini tensile test verify that this scheme can robustly and accurately compute initial guesses with semi-subpixel level accuracy in cases with small or large translation, deformation, or rotation.

  3. Expanding the Scope of an Automated Radiology Recommendation-Tracking Engine: Initial Experiences and Lessons Learned.

    PubMed

    Licurse, Mindy Y; Lalevic, Darco; Zafar, Hanna M; Schnall, Mitchell D; Cook, Tessa S

    2017-04-01

    An automated radiology recommendation-tracking engine for incidental focal masses in the liver, pancreas, kidneys, and adrenal glands was launched within our institution in July 2013. For 2 years, the majority of CT, MR, and US examination reports generated within our health system were mined by the engine. However, the need to expand the system beyond the initial four organs was soon identified. In July 2015, the second phase of the system was implemented and expanded to include additional anatomic structures in the abdomen and pelvis, as well as to provide non-radiology and non-imaging options for follow-up. The most frequent organs with incidental findings, outside of the original four, included the ovaries and the endometrium, which also correlated to the most frequently ordered imaging follow-up study of pelvic ultrasound and non-imaging follow-up study of endometrial biopsies, respectively. The second phase expansion has demonstrated new venues for augmenting and improving radiologist roles in optimal communication and management of incidental findings.

  4. Emergency department evaluation and treatment of cervical spine injuries.

    PubMed

    Kanwar, Rajdeep; Delasobera, Bronson E; Hudson, Korin; Frohna, William

    2015-05-01

    Most spinal cord injuries involve the cervical spine, highlighting the importance of recognition and proper management by emergency physicians. Initial cervical spine injury management should follow the ABCDE (airway, breathing, circulation, disability, exposure) procedure detailed by Advanced Trauma Life Support. NEXUS (National Emergency X-Radiography Utilization Study) criteria and Canadian C-spine Rule are clinical decision-making tools providing guidelines of when to obtain imaging. Computed tomography scans are the preferred initial imaging modality. Consider administering intravenous methylprednisolone after discussion with the neurosurgical consultant in patients who present with spinal cord injuries within 8 hours. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. 18F-fluorodeoxyglucose-positron emission tomography scanning is more useful in followup than in the initial assessment of patients with Erdheim-Chester disease.

    PubMed

    Arnaud, Laurent; Malek, Zoulikha; Archambaud, Frédérique; Kas, Aurélie; Toledano, Dan; Drier, Aurélie; Zeitoun, Delphine; Cluzel, Philippe; Grenier, Philippe A; Chiras, Jacques; Piette, Jean-Charles; Amoura, Zahir; Haroche, Julien

    2009-10-01

    Erdheim-Chester disease (ECD) is a rare form of non-Langerhans' cell histiocytosis. The aim of this study was to assess the value of whole-body scanning with (18)F-fluorodeoxyglucose-positron emission tomography (FDG-PET) in a large cohort of ECD patients from a single center. We retrospectively reviewed all PET scans performed on 31 patients with ECD who were referred to our department between 2005 and 2008. PET images were reviewed by 2 independent nuclear medicine specialist physicians and were compared with other imaging modalities performed within 15 days of each PET scan. Thirty-one patients (10 women and 21 men; median age 59.5 years) underwent a total of 65 PET scans. Twenty-three patients (74%) were untreated at the time of the initial PET scan, whereas 30 of the 34 followup PET scans (88%) were performed in patients who were undergoing immunomodulatory therapy. Comparison of the initial and followup PET scans with other imaging modalities revealed that the sensitivity of PET scanning varied greatly among the different organs studied (range 4.3-100%), while the specificity remained high (range 69.2-100%). Followup PET scans were particularly helpful in assessing central nervous system (CNS) involvement, since the PET scan was able to detect an early therapeutic response of CNS lesions, even before magnetic resonance imaging showed a decrease in their size. PET scanning was also very helpful in evaluating the cardiovascular system, which is a major prognostic factor in ECD, by assessing the heart and the entire vascular tree during a single session. The results of our large, single-center, retrospective study suggest that the findings of a FDG-PET scan may be interesting in the initial assessment of patients with ECD, but its greater contribution is in followup of these patients.

  6. Mobile Aerial Tracking and Imaging System (MATRIS) for Aeronautical Research

    NASA Technical Reports Server (NTRS)

    Banks, Daniel W.; Blanchard, R. C.; Miller, G. M.

    2004-01-01

    A mobile, rapidly deployable ground-based system to track and image targets of aeronautical interest has been developed. Targets include reentering reusable launch vehicles (RLVs) as well as atmospheric and transatmospheric vehicles. The optics were designed to image targets in the visible and infrared wavelengths. To minimize acquisition cost and development time, the system uses commercially available hardware and software where possible. The conception and initial funding of this system originated with a study of ground-based imaging of global aerothermal characteristics of RLV configurations. During that study NASA teamed with the Missile Defense Agency/Innovative Science and Technology Experimentation Facility (MDA/ISTEF) to test techniques and analysis on two Space Shuttle flights.

  7. SU-F-T-261: Reconstruction of Initial Photon Fluence Based On EPID Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seliger, T; Engenhart-Cabillic, R; Czarnecki, D

    2016-06-15

    Purpose: Verifying an algorithm to reconstruct relative initial photon fluence for clinical use. Clinical EPID and CT images were acquired to reconstruct an external photon radiation treatment field. The reconstructed initial photon fluence could be used to verify the treatment or calculate the applied dose to the patient. Methods: The acquired EPID images were corrected for scatter caused by the patient and the EPID with an iterative reconstruction algorithm. The transmitted photon fluence behind the patient was calculated subsequently. Based on the transmitted fluence the initial photon fluence was calculated using a back-projection algorithm which takes the patient geometry andmore » its energy dependent linear attenuation into account. This attenuation was gained from the acquired cone-beam CT or the planning CT by calculating a water-equivalent radiological thickness for each irradiation direction. To verify the algorithm an inhomogeneous phantom consisting of three inhomogeneities was irradiated by a static 6 MV photon field and compared to a reference flood field image. Results: The mean deviation between the reconstructed relative photon fluence for the inhomogeneous phantom and the flood field EPID image was 3% rising up to 7% for off-axis fluence. This was probably caused by the used clinical EPID calibration, which flattens the inhomogeneous fluence profile of the beam. Conclusion: In this clinical experiment the algorithm achieved good results in the center of the field while it showed high deviation of the lateral fluence. This could be reduced by optimizing the EPID calibration, considering the off-axis differential energy response. In further progress this and other aspects of the EPID, eg. field size dependency, CT and dose calibration have to be studied to realize a clinical acceptable accuracy of 2%.« less

  8. Reducing Wait Time for Lung Cancer Diagnosis and Treatment: Impact of a Multidisciplinary, Centralized Referral Program.

    PubMed

    Common, Jessica L; Mariathas, Hensley H; Parsons, Kaylah; Greenland, Jonathan D; Harris, Scott; Bhatia, Rick; Byrne, SuzanneC

    2018-06-04

    A multidisciplinary, centralized referral program was established at our institution in 2014 to reduce delays in lung cancer diagnosis and treatment following diagnostic imaging observed with the traditional, primary care provider-led referral process. The main objectives of this retrospective cohort study were to determine if referral to a Thoracic Triage Panel (TTP): 1) expedites lung cancer diagnosis and treatment initiation; and 2) leads to more appropriate specialist consultation. Patients with a diagnosis of lung cancer and initial diagnostic imaging between March 1, 2015, and February 29, 2016, at a Memorial University-affiliated tertiary care centre in St John's, Newfoundland, were identified and grouped according to whether they were referred to the TTP or managed through a traditional referral process. Wait times (in days) from first abnormal imaging to biopsy and treatment initiation were recorded. Statistical analysis was performed using the Wilcoxon rank-sum test. A total of 133 patients who met inclusion criteria were identified. Seventy-nine patients were referred to the TTP and 54 were managed by traditional means. There was a statistically significant reduction in median wait times for patients referred to the TTP. Wait time from first abnormal imaging to biopsy decreased from 61.5 to 36.0 days (P < .0001). Wait time from first abnormal imaging to treatment initiation decreased from 118.0 to 80.0 days (P < .001). The percentage of specialist consultations that led to treatment was also greater for patients referred to the TTP. A collaborative, centralized intake and referral program helps to reduce wait time for diagnosis and treatment of lung cancer. Copyright © 2018 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  9. Transverse Phase Space Reconstruction and Emittance Measurement of Intense Electron Beams using a Tomography Technique

    NASA Astrophysics Data System (ADS)

    Stratakis, D.; Kishek, R. A.; Li, H.; Bernal, S.; Walter, M.; Tobin, J.; Quinn, B.; Reiser, M.; O'Shea, P. G.

    2006-11-01

    Tomography is the technique of reconstructing an image from its projections. It is widely used in the medical community to observe the interior of the human body by processing multiple x-ray images taken at different angles, A few pioneering researchers have adapted tomography to reconstruct detailed phase space maps of charged particle beams. Some questions arise regarding the limitations of tomography technique for space charge dominated beams. For instance is the linear space charge force a valid approximation? Does tomography equally reproduce phase space for complex, experimentally observed, initial particle distributions? Does tomography make any assumptions about the initial distribution? This study explores the use of accurate modeling with the particle-in-cell code WARP to address these questions, using a wide range of different initial distributions in the code. The study also includes a number of experimental results on tomographic phase space mapping performed on the University of Maryland Electron Ring (UMER).

  10. Preoperative magnetic resonance imaging characteristics of oval circumscribed fast enhancing lesions in patients with newly diagnosed breast cancer.

    PubMed

    Lee, Jong Yoon; Jang, Mijung; Kim, Sun Mi; Yun, Bo La; Jang, Ja Yoon; Ahn, Hye Shin

    2018-05-01

    The aim of this study was to investigate the follow-up results and characteristics of oval circumscribed lesions with fast initial enhancement on preoperative magnetic resonance imaging (MRI) in patients with newly diagnosed breast cancer.Preoperative data from consecutive patients newly diagnosed with breast cancer between 2010 and 2013 were retrospectively reviewed. Only MRI reports containing, "oval shape, circumscribed margin, and fast initial enhancement," were extracted and analyzed. Follow-up results and clinical and pathological findings were evaluated.A total of 430 oval circumscribed lesions with fast initial enhancement were included. Forty-eight lesions were pathologically confirmed at initial workup and 382 were followed up. Among the 48 lesions, 14 were found to have additional malignancy and 34 were benign. Among the 382 followed-up lesions, only 1 was subsequently confirmed to be malignant. There were no evident changes in any of the remaining lesions during follow-up. The overall rate of malignancy was 3.5% (15/430). When lesions exhibited delayed washout enhancing kinetics (P < .001), were located ipsilaterally (P = .007), and closer to the primary tumor (P = .012), the possibility of malignancy was high. High T2-weighted imaging signal intensity suggested benignity (P = .043).Although the probability of being diagnosed with malignancy during follow-up in this study was low (0.3%), this investigation revealed several preoperative MRI characteristics that should alert clinicians to the possibility of malignancy.

  11. Initial studies using the RatCAP conscious animal PET tomograph

    NASA Astrophysics Data System (ADS)

    Woody, C.; Vaska, P.; Schlyer, D.; Pratte, J.-F.; Junnarkar, S.; Park, S.-J.; Stoll, S.; Purschke, M.; Southekal, S.; Kriplani, A.; Krishnamoorthy, S.; Maramraju, S.; Lee, D.; Schiffer, W.; Dewey, S.; Neill, J.; Kandasamy, A.; O'Connor, P.; Radeka, V.; Fontaine, R.; Lecomte, R.

    2007-02-01

    The RatCAP is a small, head-mounted PET tomograph designed to image the brain of a conscious rat without the use of anesthesia. The detector is a complete, high-performance 3D tomograph consisting of a 3.8 cm inside-diameter ring containing 12 block detectors, each of which is comprised of a 4×8 array of 2.2×2.2×5 mm 3 LSO crystals readout with a matching APD array and custom ASIC, and has a 1.8 cm axial field of view. Construction of the first working prototype detector has been completed and its performance characteristics have been measured. The results show an intrinsic spatial resolution of 2.1 mm, a time resolution of ˜14 ns FWHM, and a sensitivity of 0.7% at an energy threshold of 150 keV. First preliminary images have been obtained using 18F-FDG and 11C-methamphetamine, which show comparable image quality to those obtained from a commercial MicroPET R4 scanner. Initial studies have also been carried out to study stress levels in rats wearing the RatCAP.

  12. Simultaneous dual modality optical and MR imaging of mouse dorsal skin-fold window chamber

    NASA Astrophysics Data System (ADS)

    Salek, Mir Farrokh; Pagel, Mark D.; Gmitro, Arthur F.

    2011-02-01

    Optical imaging and MRI have both been used extensively to study tumor microenvironment. The two imaging modalities are complementary and can be used to cross-validate one another for specific measurements. We have developed a modular platform that is capable of doing optical microscopy inside an MRI instrument. To do this, an optical relay system transfers the image to outside of the MR bore to a commercial grade CCD camera. This enables simultaneous optical and MR imaging of the same tissue and thus creates the ideal situation for comparative or complementary studies using both modalities. Initial experiments have been done using GFP labeled prostate cancer cells implanted in mouse dorsal skin fold window chamber. Vascular hemodynamics and vascular permeability were studied using our imaging system. Towards this goal, we developed a dual MR-Optical contrast agent by labeling BSA with both Gd-DTPA and Alexa Fluor. Overall system design and results of these preliminary vascular studies are presented.

  13. Motion tracking to enable pre-surgical margin mapping in basal cell carcinoma using optical imaging modalities: initial feasibility study using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Duffy, M.; Richardson, T. J.; Craythorne, E.; Mallipeddi, R.; Coleman, A. J.

    2014-02-01

    A system has been developed to assess the feasibility of using motion tracking to enable pre-surgical margin mapping of basal cell carcinoma (BCC) in the clinic using optical coherence tomography (OCT). This system consists of a commercial OCT imaging system (the VivoSight 1500, MDL Ltd., Orpington, UK), which has been adapted to incorporate a webcam and a single-sensor electromagnetic positional tracking module (the Flock of Birds, Ascension Technology Corp, Vermont, USA). A supporting software interface has also been developed which allows positional data to be captured and projected onto a 2D dermoscopic image in real-time. Initial results using a stationary test phantom are encouraging, with maximum errors in the projected map in the order of 1-2mm. Initial clinical results were poor due to motion artefact, despite attempts to stabilise the patient. However, the authors present several suggested modifications that are expected to reduce the effects of motion artefact and improve the overall accuracy and clinical usability of the system.

  14. Training strategy for convolutional neural networks in pedestrian gender classification

    NASA Astrophysics Data System (ADS)

    Ng, Choon-Boon; Tay, Yong-Haur; Goi, Bok-Min

    2017-06-01

    In this work, we studied a strategy for training a convolutional neural network in pedestrian gender classification with limited amount of labeled training data. Unsupervised learning by k-means clustering on pedestrian images was used to learn the filters to initialize the first layer of the network. As a form of pre-training, supervised learning for the related task of pedestrian classification was performed. Finally, the network was fine-tuned for gender classification. We found that this strategy improved the network's generalization ability in gender classification, achieving better test results when compared to random weights initialization and slightly more beneficial than merely initializing the first layer filters by unsupervised learning. This shows that unsupervised learning followed by pre-training with pedestrian images is an effective strategy to learn useful features for pedestrian gender classification.

  15. Noninvasive in vivo optical coherence tomography tracking of chronic otitis media in pediatric subjects after surgical intervention

    NASA Astrophysics Data System (ADS)

    Monroy, Guillermo L.; Pande, Paritosh; Nolan, Ryan M.; Shelton, Ryan L.; Porter, Ryan G.; Novak, Michael A.; Spillman, Darold R.; Chaney, Eric J.; McCormick, Daniel T.; Boppart, Stephen A.

    2017-12-01

    In an institutional review board-approved study, 25 pediatric subjects diagnosed with chronic or recurrent otitis media were observed over a period of six months with optical coherence tomography (OCT). Subjects were followed throughout their treatment at the initial patient evaluation and preoperative consultation, surgery (intraoperative imaging), and postoperative follow-up, followed by an additional six months of records-based observation. At each time point, the tympanic membrane (at the light reflex region) and directly adjacent middle-ear cavity were observed in vivo with a handheld OCT probe and portable system. Imaging results were compared with clinical outcomes to correlate the clearance of symptoms in relation to changes in the image-based features of infection. OCT images of most all participants showed the presence of additional infection-related biofilm structures during their initial consultation visit and similarly for subjects imaged intraoperatively before myringotomy. Subjects with successful treatment (no recurrence of infectious symptoms) had no additional structures visible in OCT images during the postoperative visit. OCT image findings suggest surgical intervention consisting of myringotomy and tympanostomy tube placement provides a means to clear the middle ear of infection-related components, including middle-ear fluid and biofilms. Furthermore, OCT was demonstrated as a rapid diagnostic tool to prospectively monitor patients in both outpatient and surgical settings.

  16. The utilization of a non-invasive fluorescence imaging system to follow clinical dermatological MAL-PDT

    NASA Astrophysics Data System (ADS)

    Tyrrell, Jessica; Campbell, Sandra; Curnow, Alison

    2009-06-01

    This study employed a commercially available, non-invasive, fluorescence imaging system (Dyaderm, Biocam, Germany), to measure protoporphyrin IX (PpIX) concentration at several different stages during clinical dermatological methyl aminolevulinate photodynamic therapy (MAL-PDT). We validated the system prior to use to ensure that the PpIX changes witnessed were accurate and not due to environmental or user induced artifacts. The system was then employed to acquire color (morphological) and fluorescent (physiological) images simultaneously during dermatological PDT. Clinical data was collected from a range of licensed dermatological conditions (actinic keratosis, Bowen's disease and superficial basal cell carcinoma) during initial and subsequent PDT treatment cycles. The initial clinical data indicated that each type of licensed lesion considered responded in a similar manner following the application of Metvix (Galderma, U.K.) and the subsequent light irradiation (Aktilite, Galderma, U.K.). Images acquired three hours after Metvix application showed a significant increase in PpIX concentration within the lesion (P < 0.05), whilst PpIX levels in the surrounding normal tissue remained unaltered. After irradiation, the PpIX concentration was significantly decreased and returned to a level similar to the initial concentration originally observed. Lesions that received subsequent treatment cycles accumulated significantly less PpIX (P < 0.05) prior to irradiation.

  17. A fast 4D cone beam CT reconstruction method based on the OSC-TV algorithm.

    PubMed

    Mascolo-Fortin, Julia; Matenine, Dmitri; Archambault, Louis; Després, Philippe

    2018-01-01

    Four-dimensional cone beam computed tomography allows for temporally resolved imaging with useful applications in radiotherapy, but raises particular challenges in terms of image quality and computation time. The purpose of this work is to develop a fast and accurate 4D algorithm by adapting a GPU-accelerated ordered subsets convex algorithm (OSC), combined with the total variation minimization regularization technique (TV). Different initialization schemes were studied to adapt the OSC-TV algorithm to 4D reconstruction: each respiratory phase was initialized either with a 3D reconstruction or a blank image. Reconstruction algorithms were tested on a dynamic numerical phantom and on a clinical dataset. 4D iterations were implemented for a cluster of 8 GPUs. All developed methods allowed for an adequate visualization of the respiratory movement and compared favorably to the McKinnon-Bates and adaptive steepest descent projection onto convex sets algorithms, while the 4D reconstructions initialized from a prior 3D reconstruction led to better overall image quality. The most suitable adaptation of OSC-TV to 4D CBCT was found to be a combination of a prior FDK reconstruction and a 4D OSC-TV reconstruction with a reconstruction time of 4.5 minutes. This relatively short reconstruction time could facilitate a clinical use.

  18. Initial direct comparison of 99mTc-TOC and 99mTc-TATE in identifying sites of disease in patients with proven GEP NETs.

    PubMed

    Cwikla, Jaroslaw B; Mikolajczak, Renata; Pawlak, Dariusz; Buscombe, John R; Nasierowska-Guttmejer, Anna; Bator, Andrzej; Maecke, Helmut R; Walecki, Jerzy

    2008-07-01

    The imaging of neuroendocrine tumors has become one of the most significant areas in nuclear oncology. In an attempt to provide high-quality imaging and possible sensitivity at a reduced cost, time, and radiation dose, several (99m)Tc agents have been proposed. The aim of this initial study was to compare the tumor uptake and biodistribution of 2 new 6-hydrazinopyridine-3-carboxylic acid (HYNIC)-derivatized Tyr(3)-octreotide analogs, (99m)Tc-[HYNIC,Tyr(3)]octreotide ((99m)Tc-TOC) and (99m)Tc-[HYNIC,Tyr(3),Thr(8)]octreotide ((99m)Tc-TATE), in patients with somatostatin receptor-expressing tumors. Each of 12 patients with proven gastrointestinal pancreatic neuroendocrine tumors received a mean activity of 520 MBq of (99m)Tc-TOC and (99m)Tc-TATE. Scintigraphy with both tracers was performed 3-4 h after their injection using standard whole-body and SPECT imaging. The images were reviewed subjectively by 2 readers, who reported tumor uptake lesion by lesion. Both radiotracers demonstrated concordance between the results in 7 patients (58%). In total, 110 sites of disease were identified with (99m)Tc-TOC, compared with 115 with (99m)Tc-TATE. There was 1 case in which (99m)Tc-TOC identified sites of disease not seen on (99m)Tc-TATE imaging but 4 cases in which some sites of disease were seen with (99m)Tc-TATE and not (99m)Tc-TOC. In this initial study, both tracers seem to show similar sites of tumor, with (99m)Tc-TATE having a slight edge in the total number of lesions seen, especially in lymph node metastases.

  19. Dynamic Initiator Imaging at the Advanced Photon Source: Understanding the early stages of initiator function and subsequent explosive interactions

    NASA Astrophysics Data System (ADS)

    Sanchez, Nate; Neal, Will; Jensen, Brian; Gibson, John; Martinez, Mike; Jaramillo, Dennis; Iverson, Adam; Carlson, Carl

    2017-06-01

    Recent advances in diagnostics coupled with synchrotron sources have allowed the in-situ investigation of exploding foil initiators (EFI) during flight. We present the first images of EFIs during flight utilizing x-ray phase contrast imaging at the Advanced Photon Source (APS) located in Argonne National Laboratory. These images have provided the DOE/DoD community with unprecedented images resolving details on the micron scale of the flyer formation, plasma instabilities and in flight characteristics along with the subsequent interaction with high explosives on the nanosecond time scale. Phase contrast imaging has allowed the ability to make dynamic measurements on the length and time scale necessary to resolve initiator function and provide insight to key design parameters. These efforts have also probed the fundamental physics at ``burst'' to better understand what burst means in a physical sense, rather than the traditional understanding of burst as a peak in voltage and increase in resistance. This fundamental understanding has led to increased knowledge on the mechanisms of burst and has allowed us to improve our predictive capability through magnetohydrodnamic modeling. Results will be presented from several EFI designs along with a look to the future for upcoming work.

  20. Characteristics of Rib Fractures in Child Abuse-The Role of Low-Dose Chest Computed Tomography.

    PubMed

    Sanchez, Thomas R; Grasparil, Angelo D; Chaudhari, Ruchir; Coulter, Kevin P; Wootton-Gorges, Sandra L

    2018-02-01

    Our aim is to describe the radiologic characteristics of rib fractures in clinically diagnosed cases of child abuse and suggest a complementary imaging for radiographically occult injuries in highly suspicious cases of child abuse. Retrospective analysis of initial and follow-up skeletal surveys and computed tomography (CT) scans of 16 patients younger than 12 months were reviewed after obtaining approval from our institutional review board. The number, location, displacement, and age of the rib fractures were recorded. Out of a total 105 rib fractures, 84% (87/105) were detected on the initial skeletal survey. Seventeen percent (18/105) were seen only after follow-up imaging, more than half of which (11/18) were detected on a subsequent CT. Majority of the fractures were posterior (43%) and anterior (30%) in location. An overwhelming majority (96%) of the fractures are nondisplaced. Seventeen percent of rib fractures analyzed in the study were not documented on the initial skeletal survey. Majority of fractures are nondisplaced and located posteriorly or anteriorly, areas that are often difficult to assess especially in the acute stage. The CT scan is more sensitive in evaluating these types of fractures. Low-dose chest CT can be an important imaging modality for suspicious cases of child abuse when initial radiographic findings are inconclusive.

  1. Chest imaging features of patients afflicted with Influenza A (H1N1) in a Malaysian tertiary referral centre

    PubMed Central

    Bux, SI; Mohd. Ramli, N; Ahmad Sarji, S; Kamarulzaman, A

    2010-01-01

    This is a retrospective descriptive study of the chest imaging findings of 118 patients with confirmed A(H1N1) in a tertiary referral centre. About 42% of the patients had positive initial chest radiographic (CXR) findings. The common findings were bi-basal air-space opacities and perihilar reticular and alveolar infiltrates. In select cases, high-resolution computed tomography (CT) imaging showed ground-glass change with some widespread reticular changes and atelectasis. PMID:21611071

  2. Research on the Hotel Image Based on the Detail Service

    NASA Astrophysics Data System (ADS)

    Li, Ban; Shenghua, Zheng; He, Yi

    Detail service management, initially developed as marketing programs to enhance customer loyalty, has now become an important part of customer relation strategy. This paper analyzes the critical factors of detail service and its influence on the hotel image. We establish the theoretical model of influencing factors on hotel image and propose corresponding hypotheses. We use applying statistical method to test and verify the above-mentioned hypotheses. This paper provides a foundation for further study of detail service design and planning issues.

  3. Targeting Body Image Schema for Smoking Cessation among College Females: Rationale, Program Description, and Pilot Study Results

    ERIC Educational Resources Information Center

    Napolitano, Melissa A.; Lloyd-Richardson, Elizabeth E.; Fava, Joseph L.; Marcus, Bess H.

    2011-01-01

    Smoking among young adults is a significant public health problem. Despite the negative health effects, many young women smoke for weight and body image reasons. Understanding the factors that prompt young women to initiate and continue smoking is important for designing smoking cessation interventions. The aim of the current article is to outline…

  4. Angiogram, fundus, and oxygen saturation optic nerve head image fusion

    NASA Astrophysics Data System (ADS)

    Cao, Hua; Khoobehi, Bahram

    2009-02-01

    A novel multi-modality optic nerve head image fusion approach has been successfully designed. The new approach has been applied on three ophthalmologic modalities: angiogram, fundus, and oxygen saturation retinal optic nerve head images. It has achieved an excellent result by giving the visualization of fundus or oxygen saturation images with a complete angiogram overlay. During this study, two contributions have been made in terms of novelty, efficiency, and accuracy. The first contribution is the automated control point detection algorithm for multi-sensor images. The new method employs retina vasculature and bifurcation features by identifying the initial good-guess of control points using the Adaptive Exploratory Algorithm. The second contribution is the heuristic optimization fusion algorithm. In order to maximize the objective function (Mutual-Pixel-Count), the iteration algorithm adjusts the initial guess of the control points at the sub-pixel level. A refinement of the parameter set is obtained at the end of each loop, and finally an optimal fused image is generated at the end of the iteration. It is the first time that Mutual-Pixel-Count concept has been introduced into biomedical image fusion area. By locking the images in one place, the fused image allows ophthalmologists to match the same eye over time and get a sense of disease progress and pinpoint surgical tools. The new algorithm can be easily expanded to human or animals' 3D eye, brain, or body image registration and fusion.

  5. The Economic and Social Value of an Image Exchange Network: A Case for the Cloud.

    PubMed

    Mayo, Ray Cody; Pearson, Kathryn L; Avrin, David E; Leung, Jessica W T

    2017-01-01

    As the health care environment continually changes, radiologists look to the ACR's Imaging 3.0 ® initiative to guide the search for value. By leveraging new technology, a cloud-based image exchange network could provide secure universal access to prior images, which were previously siloed, to facilitate accurate interpretation, improved outcomes, and reduced costs. The breast imaging department represents a viable starting point given the robust data supporting the benefit of access to prior imaging studies, existing infrastructure for image sharing, and the current workflow reliance on prior images. This concept is scalable not only to the remainder of the radiology department but also to the broader medical record. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  6. Brain Response to Working Memory Over Three Years of Adolescence: Influence of Initiating Heavy Drinking

    PubMed Central

    Squeglia, Lindsay M.; Pulido, Carmen; Wetherill, Reagan R.; Jacobus, Joanna; Brown, Gregory G.; Tapert, Susan F.

    2012-01-01

    Objective: Many adolescents engage in heavy alcohol use. The aim of this study was to disentangle whether brain abnormalities seen in adolescent heavy drinkers are a consequence of heavy drinking, a preexisting risk factor for initiation of alcohol use, or both. Method: Study 1 used cross-sectional functional magnetic resonance imaging (fMRI) visual working-memory (VWM) data from 15- to 19-year-olds (20 heavy drinkers, 20 controls) to identify brain regions affected by heavy adolescent alcohol use. Study 2 used longitudinal fMRI VWM data from 12- to 16-year-olds imaged before the onset of drinking and imaged again on the same scanner approximately 3 years later. Those who had transitioned into heavy drinking (n = 20) were matched to continuous nondrinkers (n = 20) on baseline alcohol risk and developmental factors (N = 40; 80 scans). Results: Study 1 found that heavy drinkers exhibited more frontal and parietal but less occipital activation than controls, defining the regions of interest for Study 2. In Study 2, adolescents who later transitioned into heavy drinking showed less fMRI response contrast at baseline than continuous nondrinkers, which increased after the onset of heavy drinking, in frontal (1,431 μL, p = .003; η2 = .19) and parietal (810 μL, p = .005; η2 = .23) regions, as in Study 1. Lower baseline activation in the frontal and parietal regions predicted subsequent substance use, more so than commonly observed predictors of youth drinking (p < .05). Conclusions: Adolescents who initiated heavy drinking showed different brain activation before the onset of drinking, then less efficient information processing after high-dose alcohol use started. This suggests neural response patterns that could be risk factors for future substance use and also supports prior neuropsychological reports indicating that initiating heavy episodic drinking in adolescence may be followed by subtle alterations in brain functioning. PMID:22846239

  7. Multi-parametric studies of electrically-driven flyer plates

    NASA Astrophysics Data System (ADS)

    Neal, William; Bowden, Michael; Explosive Trains; Devices Collaboration

    2015-06-01

    Exploding foil initiator (EFI) detonators function by the acceleration of a flyer plate, by the electrical explosion of a metallic bridge, into an explosive pellet. The length, and therefore time, scales of this shock initation process is dominated by the magnitude and duration of the imparted shock pulse. To predict the dynamics of this initiation, it is critical to further understand the velocity, shape and thickness of this flyer plate. This study uses multi-parametric diagnostics to investigate the geometry and velocity of the flyer plate upon impact including the imparted electrical energy: photon Doppler velocimetry (PDV), dual axis imaging, time-resolved impact imaging, voltage and current. The investigation challenges the validity of traditional assumptions about the state of the flyer plate at impact and discusses the improved understanding of the process.

  8. Digital imaging technology assessment: Digital document storage project

    NASA Technical Reports Server (NTRS)

    1989-01-01

    An ongoing technical assessment and requirements definition project is examining the potential role of digital imaging technology at NASA's STI facility. The focus is on the basic components of imaging technology in today's marketplace as well as the components anticipated in the near future. Presented is a requirement specification for a prototype project, an initial examination of current image processing at the STI facility, and an initial summary of image processing projects at other sites. Operational imaging systems incorporate scanners, optical storage, high resolution monitors, processing nodes, magnetic storage, jukeboxes, specialized boards, optical character recognition gear, pixel addressable printers, communications, and complex software processes.

  9. World Wide Web Based Image Search Engine Using Text and Image Content Features

    NASA Astrophysics Data System (ADS)

    Luo, Bo; Wang, Xiaogang; Tang, Xiaoou

    2003-01-01

    Using both text and image content features, a hybrid image retrieval system for Word Wide Web is developed in this paper. We first use a text-based image meta-search engine to retrieve images from the Web based on the text information on the image host pages to provide an initial image set. Because of the high-speed and low cost nature of the text-based approach, we can easily retrieve a broad coverage of images with a high recall rate and a relatively low precision. An image content based ordering is then performed on the initial image set. All the images are clustered into different folders based on the image content features. In addition, the images can be re-ranked by the content features according to the user feedback. Such a design makes it truly practical to use both text and image content for image retrieval over the Internet. Experimental results confirm the efficiency of the system.

  10. A new approach for reducing beam hardening artifacts in polychromatic X-ray computed tomography using more accurate prior image.

    PubMed

    Wang, Hui; Xu, Yanan; Shi, Hongli

    2018-03-15

    Metal artifacts severely degrade CT image quality in clinical diagnosis, which are difficult to removed, especially for the beam hardening artifacts. The metal artifact reduction (MAR) based on prior images are the most frequently-used methods. However, there exists a lot misclassification in most prior images caused by absence of prior information such as spectrum distribution of X-ray beam source, especially when multiple or big metal are included. This work aims is to identify a more accurate prior image to improve image quality. The proposed method includes four steps. First, the metal image is segmented by thresholding an initial image, where the metal traces are identified in the initial projection data using the forward projection of the metal image. Second, the accurate absorbent model of certain metal image is calculated according to the spectrum distribution of certain X-ray beam source and energy-dependent attenuation coefficients of metal. Third, a new metal image is reconstructed by the general analytical reconstruction algorithm such as filtered back projection (FPB). The prior image is obtained by segmenting the difference image between the initial image and the new metal image into air, tissue and bone. Fourth, the initial projection data are normalized by dividing the projection data of prior image pixel to pixel. The final corrected image is obtained by interpolation, denormalization and reconstruction. Several clinical images with dental fillings and knee prostheses were used to evaluate the proposed algorithm and normalized metal artifact reduction (NMAR) and linear interpolation (LI) method. The results demonstrate the artifacts were reduced efficiently by the proposed method. The proposed method could obtain an exact prior image using the prior information about X-ray beam source and energy-dependent attenuation coefficients of metal. As a result, better performance of reducing beam hardening artifacts can be achieved. Moreover, the process of the proposed method is rather simple and little extra calculation burden is necessary. It has superiorities over other algorithms when include multiple and/or big implants.

  11. Grayscale image segmentation for real-time traffic sign recognition: the hardware point of view

    NASA Astrophysics Data System (ADS)

    Cao, Tam P.; Deng, Guang; Elton, Darrell

    2009-02-01

    In this paper, we study several grayscale-based image segmentation methods for real-time road sign recognition applications on an FPGA hardware platform. The performance of different image segmentation algorithms in different lighting conditions are initially compared using PC simulation. Based on these results and analysis, suitable algorithms are implemented and tested on a real-time FPGA speed sign detection system. Experimental results show that the system using segmented images uses significantly less hardware resources on an FPGA while maintaining comparable system's performance. The system is capable of processing 60 live video frames per second.

  12. Cost-effective teaching of radiology with preclinical anatomy.

    PubMed

    Wilson, James S; Alvarez, Jacqueline; Davis, Bonnie C; Duerinckx, Andre J

    2018-03-01

    Graduating physicians in all subspecialties have an increased need for competency in radiology, particularly since the use of diagnostic imaging continues to grow. To integrate the teaching of radiology with anatomy during the first year of medical school at Howard University, a novel approach was developed to overcome the limitations of resources including funding, faculty, and curricular time. The resulting program relies on self-study and peer-to-peer interactions to develop proficiency at manipulating free versions of medical image viewer software (using the DICOM standard), identifying normal anatomy in medical images, and applying critical thinking skills to understand common clinical conditions. An effective collaborative relationship between a radiologist and anatomist was necessary to develop and implement the program of anatomic-radiographic instruction which consists of five tiers: (1) initial exposure to anatomy through dissection which provides a foundation of knowledge; (2) study of annotated radiographs from atlases; (3) a radiology quiz open to group discussions; (4) small group study of clinical cases with diagnostic images; and (5) radiographic tests. Students took all quizzes and tests by working from image datasets preloaded on their personal computers, mimicking the approach by which radiologists analyze medical images. In addition to stimulating student support of a new teaching initiative, the strengths of Howard's program are that it can be introduced into an existing preclinical curriculum in almost any medical school with minimal disruption, it requires few additional resources to implement and run, and its design is consistent with the principles of modern education theory. Anat Sci Educ 11: 196-206. © 2017 American Association of Anatomists. © 2017 American Association of Anatomists.

  13. Initial Characterization of Colombian High School Physics Teachers' Pedagogical Content Knowledge on Electric Fields

    ERIC Educational Resources Information Center

    Melo-Niño, Lina Viviana; Cañada, Florentina; Mellado, Vicente

    2017-01-01

    We explore the initial characterization of the pedagogical content knowledge of four, in-service, Colombian pre-university secondary education physics teachers on the concept of electric field. Two of them teach the content in English as a second language. The aim of the study was to obtain an image of the participants' teaching of electric field…

  14. Cell-based therapies and imaging in cardiology.

    PubMed

    Bengel, Frank M; Schachinger, Volker; Dimmeler, Stefanie

    2005-12-01

    Cell therapy for cardiac repair has emerged as one of the most exciting and promising developments in cardiovascular medicine. Evidence from experimental and clinical studies is increasing that this innovative treatment will influence clinical practice in the future. But open questions and controversies with regard to the basic mechanisms of this therapy continue to exist and emphasise the need for specific techniques to visualise the mechanisms and success of therapy in vivo. Several non-invasive imaging approaches which aim at tracking of transplanted cells in the heart have been introduced. Among these are direct labelling of cells with radionuclides or paramagnetic agents, and the use of reporter genes for imaging of cell transplantation and differentiation. Initial studies have suggested that these molecular imaging techniques have great potential. Integration of cell imaging into studies of cardiac cell therapy holds promise to facilitate further growth of the field towards a broadly clinically useful application.

  15. Initial In Vivo Quantification of Tc-99m Sestamibi Uptake as a Function of Tissue Type in Healthy Breasts Using Dedicated Breast SPECT-CT

    PubMed Central

    Mann, Steve D.; Perez, Kristy L.; McCracken, Emily K. E.; Shah, Jainil P.; Wong, Terence Z.; Tornai, Martin P.

    2012-01-01

    A pilot study is underway to quantify in vivo the uptake and distribution of Tc-99m Sestamibi in subjects without previous history of breast cancer using a dedicated SPECT-CT breast imaging system. Subjects undergoing diagnostic parathyroid imaging studies were consented and imaged as part of this IRB-approved breast imaging study. For each of the seven subjects, one randomly selected breast was imaged prone-pendant using the dedicated, compact breast SPECT-CT system underneath the shielded patient support. Iteratively reconstructed and attenuation and/or scatter corrected images were coregistered; CT images were segmented into glandular and fatty tissue by three different methods; the average concentration of Sestamibi was determined from the SPECT data using the CT-based segmentation and previously established quantification techniques. Very minor differences between the segmentation methods were observed, and the results indicate an average image-based in vivo Sestamibi concentration of 0.10 ± 0.16 μCi/mL with no preferential uptake by glandular or fatty tissues. PMID:22956950

  16. Variations in the size of focal nodular hyperplasia on magnetic resonance imaging.

    PubMed

    Ramírez-Fuentes, C; Martí-Bonmatí, L; Torregrosa, A; Del Val, A; Martínez, C

    2013-01-01

    To evaluate the changes in the size of focal nodular hyperplasia (FNH) during long-term magnetic resonance imaging (MRI) follow-up. We reviewed 44 FNHs in 30 patients studied with MRI with at least two MRI studies at least 12 months apart. We measured the largest diameter of the lesion (inmm) in contrast-enhanced axial images and calculated the percentage of variation as the difference between the maximum diameter in the follow-up and the maximum diameter in the initial study. We defined significant variation in size as variation greater than 20%. We also analyzed predisposing hormonal factors. The mean interval between the two imaging studies was 35±2 months (range: 12-94). Most lesions (80%) remained stable during follow-up. Only 9 of the 44 lesions (20%) showed a significant variation in diameter: 7 (16%) decreased in size and 2 (4%) increased, with variations that reached the double of the initial size. The change in size was not related to pregnancy, menopause, or the use of birth control pills or corticoids. Changes in the size of FNHs during follow-up are relatively common and should not lead to a change in the diagnosis. These variations in size seem to be independent of hormonal factors that are considered to predispose. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  17. Effect of resin infiltration on white spot lesions after debonding orthodontic brackets.

    PubMed

    Hammad, Shaza M; El Banna, Mai; El Zayat, Inas; Mohsen, Mohamed Abdel

    2012-02-01

    To evaluate the effect of application of a resin infiltration material on masking the white spot lesions (WSLs) after bracket removal. 18 patients participated in this study and were divided into two groups of nine patients each; by a visual score based on the extent of demineralization, according to the classification of the WSLs. Group 1: Visible WSLs without surface disruption and Group 2: WSLs showed a roughened surface but not requiring restoration. Three successive photographs were taken for every patient; immediately after bracket removal, 1 week after oral hygiene measures and after Icon material application. The JPEG images were imported into image analysis software (Image J version 1.33u for Windows XP, US National Institutes of Health) which presented the images into histograms of gray scale from (0 to 255). Initial and final images were compared for percentage of WSLs masking area. For both groups, a statistically significant difference at P<0.05 was obtained as follows; for WSLs in Group 1, the means at gray scale for the initial and the final photographs were 126.091 +/- 13.452 and 221.268 +/- 9.350 respectively and they revealed significance by Wilcoxon's signed rank test = 0.038, P<0.05. For WSLs in Group 2, the means at gray scale for the initial and the final photographs were 95.585 +/- 20.973 and 155.612 +/- 31.203 respectively and they revealed significance by Wilcoxon's signed rank test = 0.029, P<0.05.

  18. Dual-Tree Complex Wavelet Transform and Image Block Residual-Based Multi-Focus Image Fusion in Visual Sensor Networks

    PubMed Central

    Yang, Yong; Tong, Song; Huang, Shuying; Lin, Pan

    2014-01-01

    This paper presents a novel framework for the fusion of multi-focus images explicitly designed for visual sensor network (VSN) environments. Multi-scale based fusion methods can often obtain fused images with good visual effect. However, because of the defects of the fusion rules, it is almost impossible to completely avoid the loss of useful information in the thus obtained fused images. The proposed fusion scheme can be divided into two processes: initial fusion and final fusion. The initial fusion is based on a dual-tree complex wavelet transform (DTCWT). The Sum-Modified-Laplacian (SML)-based visual contrast and SML are employed to fuse the low- and high-frequency coefficients, respectively, and an initial composited image is obtained. In the final fusion process, the image block residuals technique and consistency verification are used to detect the focusing areas and then a decision map is obtained. The map is used to guide how to achieve the final fused image. The performance of the proposed method was extensively tested on a number of multi-focus images, including no-referenced images, referenced images, and images with different noise levels. The experimental results clearly indicate that the proposed method outperformed various state-of-the-art fusion methods, in terms of both subjective and objective evaluations, and is more suitable for VSNs. PMID:25587878

  19. Dual-tree complex wavelet transform and image block residual-based multi-focus image fusion in visual sensor networks.

    PubMed

    Yang, Yong; Tong, Song; Huang, Shuying; Lin, Pan

    2014-11-26

    This paper presents a novel framework for the fusion of multi-focus images explicitly designed for visual sensor network (VSN) environments. Multi-scale based fusion methods can often obtain fused images with good visual effect. However, because of the defects of the fusion rules, it is almost impossible to completely avoid the loss of useful information in the thus obtained fused images. The proposed fusion scheme can be divided into two processes: initial fusion and final fusion. The initial fusion is based on a dual-tree complex wavelet transform (DTCWT). The Sum-Modified-Laplacian (SML)-based visual contrast and SML are employed to fuse the low- and high-frequency coefficients, respectively, and an initial composited image is obtained. In the final fusion process, the image block residuals technique and consistency verification are used to detect the focusing areas and then a decision map is obtained. The map is used to guide how to achieve the final fused image. The performance of the proposed method was extensively tested on a number of multi-focus images, including no-referenced images, referenced images, and images with different noise levels. The experimental results clearly indicate that the proposed method outperformed various state-of-the-art fusion methods, in terms of both subjective and objective evaluations, and is more suitable for VSNs.

  20. Cardiac biplane strain imaging: initial in vivo experience

    NASA Astrophysics Data System (ADS)

    Lopata, R. G. P.; Nillesen, M. M.; Verrijp, C. N.; Singh, S. K.; Lammens, M. M. Y.; van der Laak, J. A. W. M.; van Wetten, H. B.; Thijssen, J. M.; Kapusta, L.; de Korte, C. L.

    2010-02-01

    In this study, first we propose a biplane strain imaging method using a commercial ultrasound system, yielding estimation of the strain in three orthogonal directions. Secondly, an animal model of a child's heart was introduced that is suitable to simulate congenital heart disease and was used to test the method in vivo. The proposed approach can serve as a framework to monitor the development of cardiac hypertrophy and fibrosis. A 2D strain estimation technique using radio frequency (RF) ultrasound data was applied. Biplane image acquisition was performed at a relatively low frame rate (<100 Hz) using a commercial platform with an RF interface. For testing the method in vivo, biplane image sequences of the heart were recorded during the cardiac cycle in four dogs with an aortic stenosis. Initial results reveal the feasibility of measuring large radial, circumferential and longitudinal cumulative strain (up to 70%) at a frame rate of 100 Hz. Mean radial strain curves of a manually segmented region-of-interest in the infero-lateral wall show excellent correlation between the measured strain curves acquired in two perpendicular planes. Furthermore, the results show the feasibility and reproducibility of assessing radial, circumferential and longitudinal strains simultaneously. In this preliminary study, three beagles developed an elevated pressure gradient over the aortic valve (Δp: 100-200 mmHg) and myocardial hypertrophy. One dog did not develop any sign of hypertrophy (Δp = 20 mmHg). Initial strain (rate) results showed that the maximum strain (rate) decreased with increasing valvular stenosis (-50%), which is in accordance with previous studies. Histological findings corroborated these results and showed an increase in fibrotic tissue for the hearts with larger pressure gradients (100, 200 mmHg), as well as lower strain and strain rate values.

  1. Revision of gonadal radiation dose to man from thallium-201

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hosain, P.; Hosain, F.

    1981-06-01

    Thallium-201 as thallous chloride is now routinely used for myocardial imaging. We observed a biological translocation of T1-201 leading to a gradual increase in the concentration of radioactivity in the testes which facilitated testicular imaging. The initial distribution of intravenously injected tracer dose is greatly dependent on the distribution of cardiac output, but its metabolic fate is analogous to the potassium ion. We have extensively studied the kinetics of thallium in rats, and also carried out limited comparative studies in different species. An attempt was also made to compare the uptake values that could be obtained in dogs by quantitativemore » imaging and by autopsy. Separation of scrotum, epididymis and testes revealed that the increase in uptake occurred predominantly in the testes. The uptake increased with time for about 1 day, and after 2 days it declined with a biological half-life of approximately 2 days. The later phase of testicular clearance was similar to the rate of clearance from other organs. The testicular uptake of T1-201 was highest in rats: the initial value at 10 to 15 min was 0.48 +- 0.09% of the injected dose which increased to 1.77 +- 0.20% by 1 day. The initial uptake in mice was low (0.18 +- 0.06%) but it increased to about 4 folds by 1 day. Values in human, extrapolated from limited quantitative imaging, was similar to mice. These studies indicated the need for the revision of the gonadal radiation dose to man. Calculations show, contrary to the accepted value of about 0.5 rads/mCi, an approximate value of 1.5 rads/mCi is more realistic.« less

  2. Positron emission tomography: a novel technique for investigating the biodistribution and transport of nanoparticles.

    PubMed

    Palko, Heather A; Fung, Jennifer Y; Louie, Angelique Y

    2010-07-01

    Particulate matter (PM) has been associated with serious health effects within but also outside of the pulmonary system. Therefore, there is great interest in studying the biodistribution of PM after delivery to the lung to correlate sites of extrapulmonary particle accumulation and abnormal conditions known to be associated with PM exposure. Traditional PM tracking studies have introduced nanoparticles to animal models or humans and have determined the biodistribution with gamma counting, gamma camera, and inductively coupled plasma mass spectrometry (ICP-MS). The authors here demonstrate that positron emission tomography (PET) is a powerful tool that can be employed to visualize the deposition and track the fate of nanoparticles in the mouse model. In these studies, approximately 100-nm polystyrene nanoparticles were labeled with the positron emitter 64Cu bound by the chelator (S)-2-(4-isothiocyanatobenzyl)-1,4,7,10-tetraazacyclododecane-tetraacetic acid (p-SCN-Bn-DOTA). The labeled nanoparticles were instilled intratracheally into C57BL/6 mice; the initial deposition and biodistribution through 48 h was determined by PET imaging. In addition to static imaging, dynamic imaging was performed in the Sprague-Dawley rat model to demonstrate that PET can capture particle movement in pseudo-time-lapse videos. Particle deposition and clearance was clearly identified by PET, and the same animals could be imaged repeatedly without any adverse effects from anesthesia. PET has the potential to require many fewer animals than traditional methods while still providing quantitative results. In addition, the initial deposition pattern in each animal can be accurately determined and the same animal monitored over time so that data interpretation is not clouded by variations in initial deposition profiles.

  3. Brain Imaging in Alzheimer Disease

    PubMed Central

    Johnson, Keith A.; Fox, Nick C.; Sperling, Reisa A.; Klunk, William E.

    2012-01-01

    Imaging has played a variety of roles in the study of Alzheimer disease (AD) over the past four decades. Initially, computed tomography (CT) and then magnetic resonance imaging (MRI) were used diagnostically to rule out other causes of dementia. More recently, a variety of imaging modalities including structural and functional MRI and positron emission tomography (PET) studies of cerebral metabolism with fluoro-deoxy-d-glucose (FDG) and amyloid tracers such as Pittsburgh Compound-B (PiB) have shown characteristic changes in the brains of patients with AD, and in prodromal and even presymptomatic states that can help rule-in the AD pathophysiological process. No one imaging modality can serve all purposes as each have unique strengths and weaknesses. These modalities and their particular utilities are discussed in this article. The challenge for the future will be to combine imaging biomarkers to most efficiently facilitate diagnosis, disease staging, and, most importantly, development of effective disease-modifying therapies. PMID:22474610

  4. A Methodology for Anatomic Ultrasound Image Diagnostic Quality Assessment.

    PubMed

    Hemmsen, Martin Christian; Lange, Theis; Brandt, Andreas Hjelm; Nielsen, Michael Bachmann; Jensen, Jorgen Arendt

    2017-01-01

    This paper discusses the methods for the assessment of ultrasound image quality based on our experiences with evaluating new methods for anatomic imaging. It presents a methodology to ensure a fair assessment between competing imaging methods using clinically relevant evaluations. The methodology is valuable in the continuing process of method optimization and guided development of new imaging methods. It includes a three phased study plan covering from initial prototype development to clinical assessment. Recommendations to the clinical assessment protocol, software, and statistical analysis are presented. Earlier uses of the methodology has shown that it ensures validity of the assessment, as it separates the influences between developer, investigator, and assessor once a research protocol has been established. This separation reduces confounding influences on the result from the developer to properly reveal the clinical value. This paper exemplifies the methodology using recent studies of synthetic aperture sequential beamforming tissue harmonic imaging.

  5. Iterative Refinement of Transmission Map for Stereo Image Defogging Using a Dual Camera Sensor.

    PubMed

    Kim, Heegwang; Park, Jinho; Park, Hasil; Paik, Joonki

    2017-12-09

    Recently, the stereo imaging-based image enhancement approach has attracted increasing attention in the field of video analysis. This paper presents a dual camera-based stereo image defogging algorithm. Optical flow is first estimated from the stereo foggy image pair, and the initial disparity map is generated from the estimated optical flow. Next, an initial transmission map is generated using the initial disparity map. Atmospheric light is then estimated using the color line theory. The defogged result is finally reconstructed using the estimated transmission map and atmospheric light. The proposed method can refine the transmission map iteratively. Experimental results show that the proposed method can successfully remove fog without color distortion. The proposed method can be used as a pre-processing step for an outdoor video analysis system and a high-end smartphone with a dual camera system.

  6. Iterative Refinement of Transmission Map for Stereo Image Defogging Using a Dual Camera Sensor

    PubMed Central

    Park, Jinho; Park, Hasil

    2017-01-01

    Recently, the stereo imaging-based image enhancement approach has attracted increasing attention in the field of video analysis. This paper presents a dual camera-based stereo image defogging algorithm. Optical flow is first estimated from the stereo foggy image pair, and the initial disparity map is generated from the estimated optical flow. Next, an initial transmission map is generated using the initial disparity map. Atmospheric light is then estimated using the color line theory. The defogged result is finally reconstructed using the estimated transmission map and atmospheric light. The proposed method can refine the transmission map iteratively. Experimental results show that the proposed method can successfully remove fog without color distortion. The proposed method can be used as a pre-processing step for an outdoor video analysis system and a high-end smartphone with a dual camera system. PMID:29232826

  7. Live-cell imaging to measure BAX recruitment kinetics to mitochondria during apoptosis

    PubMed Central

    Maes, Margaret E.; Schlamp, Cassandra L.

    2017-01-01

    The pro-apoptotic BCL2 gene family member, BAX, plays a pivotal role in the intrinsic apoptotic pathway. Under cellular stress, BAX recruitment to the mitochondria occurs when activated BAX forms dimers, then oligomers, to initiate mitochondria outer membrane permeabilization (MOMP), a process critical for apoptotic progression. The activation and recruitment of BAX to form oligomers has been studied for two decades using fusion proteins with a fluorescent reporter attached in-frame to the BAX N-terminus. We applied high-speed live cell imaging to monitor the recruitment of BAX fusion proteins in dying cells. Data from time-lapse imaging was validated against the activity of endogenous BAX in cells, and analyzed using sigmoid mathematical functions to obtain detail of the kinetic parameters of the recruitment process at individual mitochondrial foci. BAX fusion proteins behave like endogenous BAX during apoptosis. Kinetic studies show that fusion protein recruitment is also minimally affected in cells lacking endogenous BAK or BAX genes, but that the kinetics are moderately, but significantly, different with different fluorescent tags in the fusion constructs. In experiments testing BAX recruitment in 3 different cell lines, our results show that regardless of cell type, once activated, BAX recruitment initiates simultaneously within a cell, but exhibits varying rates of recruitment at individual mitochondrial foci. Very early during BAX recruitment, pro-apoptotic molecules are released in the process of MOMP, but different molecules are released at different times and rates relative to the time of BAX recruitment initiation. These results provide a method for BAX kinetic analysis in living cells and yield greater detail of multiple characteristics of BAX-induced MOMP in living cells that were initially observed in cell free studies. PMID:28880942

  8. Live-cell imaging to measure BAX recruitment kinetics to mitochondria during apoptosis.

    PubMed

    Maes, Margaret E; Schlamp, Cassandra L; Nickells, Robert W

    2017-01-01

    The pro-apoptotic BCL2 gene family member, BAX, plays a pivotal role in the intrinsic apoptotic pathway. Under cellular stress, BAX recruitment to the mitochondria occurs when activated BAX forms dimers, then oligomers, to initiate mitochondria outer membrane permeabilization (MOMP), a process critical for apoptotic progression. The activation and recruitment of BAX to form oligomers has been studied for two decades using fusion proteins with a fluorescent reporter attached in-frame to the BAX N-terminus. We applied high-speed live cell imaging to monitor the recruitment of BAX fusion proteins in dying cells. Data from time-lapse imaging was validated against the activity of endogenous BAX in cells, and analyzed using sigmoid mathematical functions to obtain detail of the kinetic parameters of the recruitment process at individual mitochondrial foci. BAX fusion proteins behave like endogenous BAX during apoptosis. Kinetic studies show that fusion protein recruitment is also minimally affected in cells lacking endogenous BAK or BAX genes, but that the kinetics are moderately, but significantly, different with different fluorescent tags in the fusion constructs. In experiments testing BAX recruitment in 3 different cell lines, our results show that regardless of cell type, once activated, BAX recruitment initiates simultaneously within a cell, but exhibits varying rates of recruitment at individual mitochondrial foci. Very early during BAX recruitment, pro-apoptotic molecules are released in the process of MOMP, but different molecules are released at different times and rates relative to the time of BAX recruitment initiation. These results provide a method for BAX kinetic analysis in living cells and yield greater detail of multiple characteristics of BAX-induced MOMP in living cells that were initially observed in cell free studies.

  9. #LancerHealth: Using Twitter and Instagram as a tool in a campus wide health promotion initiative.

    PubMed

    Santarossa, Sara; Woodruff, Sarah J

    2018-02-05

    The present study aimed to explore using popular technology that people already have/use as a health promotion tool, in a campus wide social media health promotion initiative, entitled #LancerHealth . During a two-week period the university community was asked to share photos on Twitter and Instagram of What does being healthy on campus look like to you ?, while tagging the image with #LancerHealth . All publically tagged media was collected using the Netlytic software and analysed. Text analysis (N=234 records, Twitter; N=141 records, Instagram) revealed that the majority of the conversation was positive and focused on health and the university. Social network analysis, based on five network properties, showed a small network with little interaction. Lastly, photo coding analysis (N=71 unique image) indicated that the majority of the shared images were of physical activity (52%) and on campus (80%). Further research into this area is warranted.

  10. Mobile Aerial Tracking and Imaging System (MATrIS) for Aeronautical Research

    NASA Technical Reports Server (NTRS)

    Banks, Daniel W.; Blanchard, Robert C.; Miller, Geoffrey M.

    2004-01-01

    A mobile, rapidly deployable ground-based system to track and image targets of aeronautical interest has been developed. Targets include reentering reusable launch vehicles as well as atmospheric and transatmospheric vehicles. The optics were designed to image targets in the visible and infrared wavelengths. To minimize acquisition cost and development time, the system uses commercially available hardware and software where possible. The conception and initial funding of this system originated with a study of ground-based imaging of global aerothermal characteristics of reusable launch vehicle configurations. During that study the National Aeronautics and Space Administration teamed with the Missile Defense Agency/Innovative Science and Technology Experimentation Facility to test techniques and analysis on two Space Shuttle flights.

  11. Developing an ANSI standard for image quality tools for the testing of active millimeter wave imaging systems

    NASA Astrophysics Data System (ADS)

    Barber, Jeffrey; Greca, Joseph; Yam, Kevin; Weatherall, James C.; Smith, Peter R.; Smith, Barry T.

    2017-05-01

    In 2016, the millimeter wave (MMW) imaging community initiated the formation of a standard for millimeter wave image quality metrics. This new standard, American National Standards Institute (ANSI) N42.59, will apply to active MMW systems for security screening of humans. The Electromagnetic Signatures of Explosives Laboratory at the Transportation Security Laboratory is supporting the ANSI standards process via the creation of initial prototypes for round-robin testing with MMW imaging system manufacturers and experts. Results obtained for these prototypes will be used to inform the community and lead to consensus objective standards amongst stakeholders. Images collected with laboratory systems are presented along with results of preliminary image analysis. Future directions for object design, data collection and image processing are discussed.

  12. Plenoptic Ophthalmoscopy: A Novel Imaging Technique.

    PubMed

    Adam, Murtaza K; Aenchbacher, Weston; Kurzweg, Timothy; Hsu, Jason

    2016-11-01

    This prospective retinal imaging case series was designed to establish feasibility of plenoptic ophthalmoscopy (PO), a novel mydriatic fundus imaging technique. A custom variable intensity LED array light source adapter was created for the Lytro Gen1 light-field camera (Lytro, Mountain View, CA). Initial PO testing was performed on a model eye and rabbit fundi. PO image acquisition was then performed on dilated human subjects with a variety of retinal pathology and images were subjected to computational enhancement. The Lytro Gen1 light-field camera with custom LED array captured fundus images of eyes with diabetic retinopathy, age-related macular degeneration, retinal detachment, and other diagnoses. Post-acquisition computational processing allowed for refocusing and perspective shifting of retinal PO images, resulting in improved image quality. The application of PO to image the ocular fundus is feasible. Additional studies are needed to determine its potential clinical utility. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:1038-1043.]. Copyright 2016, SLACK Incorporated.

  13. General phase regularized reconstruction using phase cycling.

    PubMed

    Ong, Frank; Cheng, Joseph Y; Lustig, Michael

    2018-07-01

    To develop a general phase regularized image reconstruction method, with applications to partial Fourier imaging, water-fat imaging and flow imaging. The problem of enforcing phase constraints in reconstruction was studied under a regularized inverse problem framework. A general phase regularized reconstruction algorithm was proposed to enable various joint reconstruction of partial Fourier imaging, water-fat imaging and flow imaging, along with parallel imaging (PI) and compressed sensing (CS). Since phase regularized reconstruction is inherently non-convex and sensitive to phase wraps in the initial solution, a reconstruction technique, named phase cycling, was proposed to render the overall algorithm invariant to phase wraps. The proposed method was applied to retrospectively under-sampled in vivo datasets and compared with state of the art reconstruction methods. Phase cycling reconstructions showed reduction of artifacts compared to reconstructions without phase cycling and achieved similar performances as state of the art results in partial Fourier, water-fat and divergence-free regularized flow reconstruction. Joint reconstruction of partial Fourier + water-fat imaging + PI + CS, and partial Fourier + divergence-free regularized flow imaging + PI + CS were demonstrated. The proposed phase cycling reconstruction provides an alternative way to perform phase regularized reconstruction, without the need to perform phase unwrapping. It is robust to the choice of initial solutions and encourages the joint reconstruction of phase imaging applications. Magn Reson Med 80:112-125, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  14. Quantitative imaging of the human upper airway: instrument design and clinical studies

    NASA Astrophysics Data System (ADS)

    Leigh, M. S.; Armstrong, J. J.; Paduch, A.; Sampson, D. D.; Walsh, J. H.; Hillman, D. R.; Eastwood, P. R.

    2006-08-01

    Imaging of the human upper airway is widely used in medicine, in both clinical practice and research. Common imaging modalities include video endoscopy, X-ray CT, and MRI. However, no current modality is both quantitative and safe to use for extended periods of time. Such a capability would be particularly valuable for sleep research, which is inherently reliant on long observation sessions. We have developed an instrument capable of quantitative imaging of the human upper airway, based on endoscopic optical coherence tomography. There are no dose limits for optical techniques, and the minimally invasive imaging probe is safe for use in overnight studies. We report on the design of the instrument and its use in preliminary clinical studies, and we present results from a range of initial experiments. The experiments show that the instrument is capable of imaging during sleep, and that it can record dynamic changes in airway size and shape. This information is useful for research into sleep disorders, and potentially for clinical diagnosis and therapies.

  15. Cassini Scientist for a Day: a tactile experience

    NASA Astrophysics Data System (ADS)

    Canas, L.; Altobelli, N.

    2012-09-01

    In September 2011, the Cassini spacecraft took images of three targets and a challenge was launched to all students: to choose the one target they thought would provide the best science and to write an essay explaining their reasons (more information on the "Cassini Scientist for a Day" essay contest official webpage in: http://saturn.jpl.nasa.gov/education/scientistforaday10thedition/, run by NASA/JPL) The three targets presented were: Hyperion, Rhea and Titan, and Saturn. The idea behind "Cassini Scientist for a Day: a tactile experience" was to transform each of these images into schematic tactile images, highlighting relevant features apprehended through a tactile key, accompanied by a small text in Braille with some additional information. This initial approach would allow reach a broader community of students, more specifically those with visual impairment disabilities. Through proper implementation and careful study cases the adapted images associated with an explanatory key provide more resources in tactile astronomy. As the 2012 edition approaches a new set of targeted objet images will be once again transformed and adapted to visually impaired students and will aim to reach more students into participate in this international competition and to engage them in a quest to expand their knowledge in the amazing Cassini discoveries and the wonders of Saturn and its moons. As the winning essays will be published on the Cassini website and contest winners invited to participate in a dedicated teleconference with Cassini scientists from NASA's Jet Propulsion Laboratory, this initiative presents a great chance to all visually impaired students and teachers to participate in an exciting experience. These initiatives must be complemented with further information to strengthen the learning experience. However they stand as a good starting point to tackle further astronomical concepts in the classroom, especially this field that sometimes lacks the resources. Although the images are ready, any feedback received is paramount. With this initiative we would like to make a call to all interested in participating in the implementation of this project in their country. All interested parties will have the images provided in their native languages by sending the text on your native language translated from the English version.

  16. Visuospatial and psychomotor aptitude predicts endovascular performance of inexperienced individuals on a virtual reality simulator.

    PubMed

    Van Herzeele, Isabelle; O'Donoghue, Kevin G L; Aggarwal, Rajesh; Vermassen, Frank; Darzi, Ara; Cheshire, Nicholas J W

    2010-04-01

    This study evaluated virtual reality (VR) simulation for endovascular training of medical students to determine whether innate perceptual, visuospatial, and psychomotor aptitude (VSA) can predict initial and plateau phase of technical endovascular skills acquisition. Twenty medical students received didactic and endovascular training on a commercially available VR simulator. Each student treated a series of 10 identical noncomplex renal artery stenoses endovascularly. The simulator recorded performance data instantly and objectively. An experienced interventionalist rated the performance at the initial and final sessions using generic (out of 40) and procedure-specific (out of 30) rating scales. VSA were tested with fine motor dexterity (FMD, Perdue Pegboard), psychomotor ability (minimally invasive virtual reality surgical trainer [MIST-VR]), image recall (Rey-Osterrieth), and organizational aptitude (map-planning). VSA performance scores were correlated with the assessment parameters of endovascular skills at commencement and completion of training. Medical students exhibited statistically significant learning curves from the initial to the plateau performance for contrast usage (medians, 28 vs 17 mL, P < .001), total procedure time (2120 vs 867 seconds, P < .001), and fluoroscopy time (993 vs. 507 seconds, P < .001). Scores on generic and procedure-specific rating scales improved significantly (10 vs 25, P < .001; 8 vs 17 P < .001). Significant correlations were noted for FMD with initial and plateau sessions for fluoroscopy time (r(s) = -0.564, P = .010; r(s) = -.449, P = .047). FMD correlated with procedure-specific scores at the initial session (r(s) = .607, P = .006). Image recall correlated with generic skills at the end of training (r(s) = .587, P = .006). Simulator-based training in endovascular skills improved performance in medical students. There were significant correlations between initial endovascular skill and fine motor dexterity as well as with image recall at end of the training period. In addition to current recruitment strategies, VSA may be a useful tool for predictive validity studies.

  17. Achieving high-value cardiac imaging: challenges and opportunities.

    PubMed

    Wiener, David H

    2014-01-01

    Cardiac imaging is under intense scrutiny as a contributor to health care costs, with multiple initiatives under way to reduce and eliminate inappropriate testing. Appropriate use criteria are valuable guides to selecting imaging studies but until recently have focused on the test rather than the patient. Patient-centered means are needed to define the true value of imaging for patients in specific clinical situations. This article provides a definition of high-value cardiac imaging. A paradigm to judge the efficacy of echocardiography in the absence of randomized controlled trials is presented. Candidate clinical scenarios are proposed in which echocardiography constitutes high-value imaging, as well as stratagems to increase the likelihood that high-value cardiac imaging takes place in those circumstances. Copyright © 2014 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  18. Multi-focus image fusion and robust encryption algorithm based on compressive sensing

    NASA Astrophysics Data System (ADS)

    Xiao, Di; Wang, Lan; Xiang, Tao; Wang, Yong

    2017-06-01

    Multi-focus image fusion schemes have been studied in recent years. However, little work has been done in multi-focus image transmission security. This paper proposes a scheme that can reduce data transmission volume and resist various attacks. First, multi-focus image fusion based on wavelet decomposition can generate complete scene images and optimize the perception of the human eye. The fused images are sparsely represented with DCT and sampled with structurally random matrix (SRM), which reduces the data volume and realizes the initial encryption. Then the obtained measurements are further encrypted to resist noise and crop attack through combining permutation and diffusion stages. At the receiver, the cipher images can be jointly decrypted and reconstructed. Simulation results demonstrate the security and robustness of the proposed scheme.

  19. Experiments and simulations of single shock Richtmeyer-Meshkov Instability with measured, volumetric initial conditions

    NASA Astrophysics Data System (ADS)

    Sewell, Everest; Ferguson, Kevin; Greenough, Jeffrey; Jacobs, Jeffrey

    2014-11-01

    We describe new experiments of single shock Richtmeyer-Meshkov Instability (RMI) performed on the shock tube apparatus at the University of Arizona in which the initial conditions are volumetrically imaged prior to shock wave arrival. Initial perturbation plays a major role in the evolution of RMI, and previous experimental efforts only capture a narrow slice of the initial condition. The method presented uses a rastered laser sheet to capture additional images in the depth of the initial condition shortly before the experimental start time. These images are then used to reconstruct a volumetric approximation of the experimental perturbation, which is simulated using the hydrodynamics code ARES, developed at Lawrence Livermore National Laboratory (LLNL). Comparison is made between the time evolution of the interface width and the mixedness ratio measured from the experiments against the predictions from the numerical simulations.

  20. Early appendectomy reduces costs in children with perforated appendicitis.

    PubMed

    Church, Joseph T; Klein, Edwin J; Carr, Benjamin D; Bruch, Steven W

    2017-12-01

    Perforated appendicitis can be managed with early appendectomy, or nonoperative management followed by interval appendectomy. We aimed to identify the strategy with the lowest health care utilization and cost. We retrospectively reviewed the medical records of all children ≤18 years old with perforated appendicitis admitted to a single institution between January 2009 and March 2016. After excluding immunosuppressed patients and transfers from outside hospitals, we grouped the remaining patients by early or interval appendectomy. Cost accounting data were obtained from our institutional database. The primary outcome was total hospital cost over 2 y from initial admission for appendicitis. Other outcomes analyzed included initial admission costs, number of admissions, emergency room and clinic visits, percutaneous procedures, cross-sectional and overall imaging studies, and length of stay. A total of 203 children with perforated appendicitis were identified. After exclusion of immunosuppressed patients and outside hospital transfers, 94 patients were included in the study. Thirty-nine underwent early appendectomy and 55 initial nonoperative management; of these, 54 underwent elective interval appendectomy. Five of 55 patients (9%) failed initial nonoperative management and required earlier-than-planned appendectomy. Total cost over 2 y was significantly lower with early appendectomy than initial nonoperative management ($19,300 ± 14,300 versus $26,000 ± 17,500; P = 0.05). Early appendectomy resulted in fewer hospital admissions, clinic visits, invasive procedures, and imaging studies. Early appendectomy results in lower hospital costs and less health care utilization compared with initial nonoperative management with elective interval appendectomy. A prospective study will shed more light on this question and can assess the role of nonoperative management without interval appendectomy in children with perforated appendicitis. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Transfer and conversion of images based on EIT in atom vapor.

    PubMed

    Cao, Mingtao; Zhang, Liyun; Yu, Ya; Ye, Fengjuan; Wei, Dong; Guo, Wenge; Zhang, Shougang; Gao, Hong; Li, Fuli

    2014-05-01

    Transfer and conversion of images between different wavelengths or polarization has significant applications in optical communication and quantum information processing. We demonstrated the transfer of images based on electromagnetically induced transparency (EIT) in a rubidium vapor cell. In experiments, a 2D image generated by a spatial light modulator is used as a coupling field, and a plane wave served as a signal field. We found that the image carried by coupling field could be transferred to that carried by signal field, and the spatial patterns of transferred image are much better than that of the initial image. It also could be much smaller than that determined by the diffraction limit of the optical system. We also studied the subdiffraction propagation for the transferred image. Our results may have applications in quantum interference lithography and coherent Raman spectroscopy.

  2. Overview of Nonoperative Blunt Splenic Injury Management with Associated Splenic Artery Pseudoaneurysm.

    PubMed

    Morrison, Chet A; Gross, Brian W; Kauffman, Matthew; Rittenhouse, Katelyn J; Rogers, Frederick B

    2017-06-01

    The delayed development of splenic artery pseudoaneurysm (SAP) can complicate the nonoperative management of splenic injuries. We sought to determine the utility of repeat imaging in diagnosing SAP in patients managed nonoperatively without angioembolization. We hypothesized that a significant rate of SAPs would be found in this population on repeat imaging. Patients undergoing nonoperative splenic injury management from January 2011 to June 2015 were queried from the trauma registry. Rates of repeat imaging, angioembolization, readmission, and SAP development were analyzed. Further, subanalyses investigating the incidence of SAP in patients managed nonoperatively without angioembolization were conducted. A total of 133 patients met inclusion criteria. Repeat imaging rate was 40 per cent, angioembolization rate was 26 per cent, and readmission rate was 6 per cent. Within the study population, nine SAPs were found (8/9 in patients with splenic injury grade ≥III). Of these nine SAPs, three (33%) were identified on initial scans and embolized, whereas six (67%) were found on repeat imaging in patients not initially receiving angioembolization. Splenic injuries are typically managed nonoperatively without serious complications. Our results suggest patients with splenic injuries grade ≥III managed nonoperatively without angioembolization should have repeat imaging within 48 hours to rule out the possibility of SAP.

  3. Robust linearized image reconstruction for multifrequency EIT of the breast.

    PubMed

    Boverman, Gregory; Kao, Tzu-Jen; Kulkarni, Rujuta; Kim, Bong Seok; Isaacson, David; Saulnier, Gary J; Newell, Jonathan C

    2008-10-01

    Electrical impedance tomography (EIT) is a developing imaging modality that is beginning to show promise for detecting and characterizing tumors in the breast. At Rensselaer Polytechnic Institute, we have developed a combined EIT-tomosynthesis system that allows for the coregistered and simultaneous analysis of the breast using EIT and X-ray imaging. A significant challenge in EIT is the design of computationally efficient image reconstruction algorithms which are robust to various forms of model mismatch. Specifically, we have implemented a scaling procedure that is robust to the presence of a thin highly-resistive layer of skin at the boundary of the breast and we have developed an algorithm to detect and exclude from the image reconstruction electrodes that are in poor contact with the breast. In our initial clinical studies, it has been difficult to ensure that all electrodes make adequate contact with the breast, and thus procedures for the use of data sets containing poorly contacting electrodes are particularly important. We also present a novel, efficient method to compute the Jacobian matrix for our linearized image reconstruction algorithm by reducing the computation of the sensitivity for each voxel to a quadratic form. Initial clinical results are presented, showing the potential of our algorithms to detect and localize breast tumors.

  4. Faint Debris Detection by Particle Based Track-Before-Detect Method

    NASA Astrophysics Data System (ADS)

    Uetsuhara, M.; Ikoma, N.

    2014-09-01

    This study proposes a particle method to detect faint debris, which is hardly seen in single frame, from an image sequence based on the concept of track-before-detect (TBD). The most widely used detection method is detect-before-track (DBT), which firstly detects signals of targets from single frame by distinguishing difference of intensity between foreground and background then associate the signals for each target between frames. DBT is capable of tracking bright targets but limited. DBT is necessary to consider presence of false signals and is difficult to recover from false association. On the other hand, TBD methods try to track targets without explicitly detecting the signals followed by evaluation of goodness of each track and obtaining detection results. TBD has an advantage over DBT in detecting weak signals around background level in single frame. However, conventional TBD methods for debris detection apply brute-force search over candidate tracks then manually select true one from the candidates. To reduce those significant drawbacks of brute-force search and not-fully automated process, this study proposes a faint debris detection algorithm by a particle based TBD method consisting of sequential update of target state and heuristic search of initial state. The state consists of position, velocity direction and magnitude, and size of debris over the image at a single frame. The sequential update process is implemented by a particle filter (PF). PF is an optimal filtering technique that requires initial distribution of target state as a prior knowledge. An evolutional algorithm (EA) is utilized to search the initial distribution. The EA iteratively applies propagation and likelihood evaluation of particles for the same image sequences and resulting set of particles is used as an initial distribution of PF. This paper describes the algorithm of the proposed faint debris detection method. The algorithm demonstrates performance on image sequences acquired during observation campaigns dedicated to GEO breakup fragments, which would contain a sufficient number of faint debris images. The results indicate the proposed method is capable of tracking faint debris with moderate computational costs at operational level.

  5. Use and Yield of Baseline Imaging and Laboratory Testing in Stage II Breast Cancer

    PubMed Central

    Guo, Hao; Sutton, Jazmine; Spring, Laura; Faig, Jennifer; Dagogo-Jack, Ibiayi; Battelli, Chiara; Houlihan, Mary Jane; Yeh, Tsai-Chu; Come, Steven E.; Lin, Nancy U.

    2016-01-01

    Background. Despite guideline recommendations, baseline laboratory testing and advanced imaging are widely ordered in clinical practice to stage asymptomatic patients with clinical stage II breast cancer (BC). Materials and Methods. A retrospective study at two academic centers in Boston, Massachusetts, between 2006 and 2007 explored the use, results, and implications of laboratory tests, tumor markers, and imaging in patients with clinical stage II BC. Results. Among 411 patients, 233 (57%) had liver function testing, 134 (33%) had tumor marker tests, and 237 (58%) had computed tomography (CT) as part of their initial diagnostic workup. Median age was 52 (range, 23–90 years). On multivariable analysis, young age, more advanced stage, and tumor subtype (human epidermal growth receptor-positive [HER2+] and triple-negative breast cancer [TNBC]) were significantly associated with baseline CT. The rate of detection of true metastatic disease with use of baseline staging imaging was 2.1% (95% confidence interval, 0.7%–5%). It was 2.2% (3 of 135) for estrogen receptor/progesterone receptor-positive disease, 1.9% (1 of 54) for HER2+ disease, and 2.1% (1 of 48) for TNBC. At 5 years of follow-up, 46 of 406 patients were diagnosed with metastatic breast cancer. Thirty-four of 46 (73.9%) who developed recurrent disease had imaging at their initial diagnosis, and of these, five had abnormalities on their initial imaging that was correlated with where they developed metastatic disease. Conclusion. In this cohort of women with stage II BC, staging imaging at diagnosis had a low yield in detecting distant metastases (2.1%). The detection rate was not higher with HER2+ disease or TNBC, despite the trend that patients with these subtypes were more likely to undergo imaging. Implications for Practice: Despite guideline recommendations, asymptomatic patients with stage II breast cancer (BC) often undergo staging imaging with computed tomography, bone scanning, or positron emission tomography. Physicians have often reported that they order imaging despite recommendations because they believe that younger patients or patients with more aggressive BC phenotypes, such as human epidermal receptor 2-positive BC or triple-negative BC, benefit from staging imaging. In this cohort of women younger than those in prior studies, the yield of detecting distant metastatic disease in patients with clinical stage II BC was very low and the detection rate was not higher in the presence of HER2-positive or triple-negative BC. PMID:27551013

  6. Deep learning applications in ophthalmology.

    PubMed

    Rahimy, Ehsan

    2018-05-01

    To describe the emerging applications of deep learning in ophthalmology. Recent studies have shown that various deep learning models are capable of detecting and diagnosing various diseases afflicting the posterior segment of the eye with high accuracy. Most of the initial studies have centered around detection of referable diabetic retinopathy, age-related macular degeneration, and glaucoma. Deep learning has shown promising results in automated image analysis of fundus photographs and optical coherence tomography images. Additional testing and research is required to clinically validate this technology.

  7. Determination of differential cross sections and kinetic energy release of co-products from central sliced images in photo-initiated dynamic processes.

    PubMed

    Chen, Kuo-mei; Chen, Yu-wei

    2011-04-07

    For photo-initiated inelastic and reactive collisions, dynamic information can be extracted from central sliced images of state-selected Newton spheres of product species. An analysis framework has been established to determine differential cross sections and the kinetic energy release of co-products from experimental images. When one of the reactants exhibits a high recoil speed in a photo-initiated dynamic process, the present theory can be employed to analyze central sliced images from ion imaging or three-dimensional sliced fluorescence imaging experiments. It is demonstrated that the differential cross section of a scattering process can be determined from the central sliced image by a double Legendre moment analysis, for either a fixed or continuously distributed recoil speeds in the center-of-mass reference frame. Simultaneous equations which lead to the determination of the kinetic energy release of co-products can be established from the second-order Legendre moment of the experimental image, as soon as the differential cross section is extracted. The intensity distribution of the central sliced image, along with its outer and inner ring sizes, provide all the clues to decipher the differential cross section and the kinetic energy release of co-products.

  8. Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT

    PubMed Central

    Queiroz, Marcelo A.; Delso, Gaspar; Wollenweber, Scott; Deller, Timothy; Zeimpekis, Konstantinos; Huellner, Martin; de Galiza Barbosa, Felipe; von Schulthess, Gustav; Veit-Haibach, Patrick

    2015-01-01

    Purpose To evaluate the possible activity reduction in FDG-imaging in a Time-of-Flight (TOF) PET/MR, based on cross-evaluation of patient-based NECR (noise equivalent count rate) measurements in PET/CT, cross referencing with phantom-based NECR curves as well as initial evaluation of TOF-PET/MR with reduced activity. Materials and Methods A total of 75 consecutive patients were evaluated in this study. PET/CT imaging was performed on a PET/CT (time-of-flight (TOF) Discovery D 690 PET/CT). Initial PET/MR imaging was performed on a newly available simultaneous TOF-PET/MR (Signa PET/MR). An optimal NECR for diagnostic purposes was defined in clinical patients (NECRP) in PET/CT. Subsequent optimal activity concentration at the acquisition time ([A]0) and target NECR (NECRT) were obtained. These data were used to predict the theoretical FDG activity requirement of the new TOF-PET/MR system. Twenty-five initial patients were acquired with (retrospectively reconstructed) different imaging times equivalent for different activities on the simultaneous PET/MR for the evaluation of clinically realistic FDG-activities. Results The obtained values for NECRP, [A]0 and NECRT were 114.6 (± 14.2) kcps (Kilocounts per second), 4.0 (± 0.7) kBq/mL and 45 kcps, respectively. Evaluating the NECRT together with the phantom curve of the TOF-PET/MR device, the theoretical optimal activity concentration was found to be approximately 1.3 kBq/mL, which represents 35% of the activity concentration required by the TOF-PET/CT. Initial evaluation on patients in the simultaneous TOF-PET/MR shows clinically realistic activities of 1.8 kBq/mL, which represent 44% of the required activity. Conclusion The new TOF-PET/MR device requires significantly less activity to generate PET-images with good-to-excellent image quality, due to improvements in detector geometry and detector technologies. The theoretically achievable dose reduction accounts for up to 65% but cannot be fully translated into clinical routine based on the coils within the FOV and MR-sequences applied at the same time. The clinically realistic reduction in activity is slightly more than 50%. Further studies in a larger number of patients are needed to confirm our findings. PMID:26147919

  9. Technique adaptation, strategic replanning, and team learning during implementation of MR-guided brachytherapy for cervical cancer.

    PubMed

    Skliarenko, Julia; Carlone, Marco; Tanderup, Kari; Han, Kathy; Beiki-Ardakani, Akbar; Borg, Jette; Chan, Kitty; Croke, Jennifer; Rink, Alexandra; Simeonov, Anna; Ujaimi, Reem; Xie, Jason; Fyles, Anthony; Milosevic, Michael

    MR-guided brachytherapy (MRgBT) with interstitial needles is associated with improved outcomes in cervical cancer patients. However, there are implementation barriers, including magnetic resonance (MR) access, practitioner familiarity/comfort, and efficiency. This study explores a graded MRgBT implementation strategy that included the adaptive use of needles, strategic use of MR imaging/planning, and team learning. Twenty patients with cervical cancer were treated with high-dose-rate MRgBT (28 Gy in four fractions, two insertions, daily MR imaging/planning). A tandem/ring applicator alone was used for the first insertion in most patients. Needles were added for the second insertion based on evaluation of the initial dosimetry. An interdisciplinary expert team reviewed and discussed the MR images and treatment plans. Dosimetry-trigger technique adaptation with the addition of needles for the second insertion improved target coverage in all patients with suboptimal dosimetry initially without compromising organ-at-risk (OAR) sparing. Target and OAR planning objectives were achieved in most patients. There were small or no systematic differences in tumor or OAR dosimetry between imaging/planning once per insertion vs. daily and only small random variations. Peer review and discussion of images, contours, and plans promoted learning and process development. Technique adaptation based on the initial dosimetry is an efficient approach to implementing MRgBT while gaining comfort with the use of needles. MR imaging and planning once per insertion is safe in most patients as long as applicator shifts, and large anatomical changes are excluded. Team learning is essential to building individual and programmatic competencies. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  10. Breast MRI in community practice: equipment and imaging techniques at facilities in the Breast Cancer Surveillance Consortium.

    PubMed

    DeMartini, Wendy B; Ichikawa, Laura; Yankaskas, Bonnie C; Buist, Diana; Kerlikowske, Karla; Geller, Berta; Onega, Tracy; Rosenberg, Robert D; Lehman, Constance D

    2010-11-01

    MRI is increasingly used for the detection of breast carcinoma. Little is known about breast MRI techniques among community practice facilities. The aim of this study was to evaluate equipment and acquisition techniques used by community facilities across the United States, including compliance with minimum standards by the ACRIN® 6667 Trial and the European Society of Breast Imaging. Breast Cancer Surveillance Consortium facilities performing breast MRI were identified and queried by survey regarding breast MRI equipment and technical parameters. Variables included scanner field strength, coil type, acquisition coverage, slice thickness, and the timing of the initial postcontrast sequence. Results were tallied and percentages of facilities meeting ACRIN® and European Society of Breast Imaging standards were calculated. From 23 facilities performing breast MRI, results were obtained from 14 (61%) facilities with 16 MRI scanners reporting 18 imaging parameters. Compliance with equipment recommendations of ≥1.5-T field strength was 94% and of a dedicated breast coil was 100%. Eighty-three percent of acquisitions used bilateral postcontrast techniques, and 78% used slice thickness≤3 mm. The timing of initial postcontrast sequences ranged from 58 seconds to 8 minutes 30 seconds, with 63% meeting recommendations for completion within 4 minutes. Nearly all surveyed facilities met ACRIN and European Society of Breast Imaging standards for breast MRI equipment. The majority met standards for acquisition parameters, although techniques varied, in particular for the timing of initial postcontrast imaging. Further guidelines by the ACR Breast MRI Accreditation Program will be of importance in facilitating standardized and high-quality breast MRI. Copyright © 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  11. Current Status of Single Particle Imaging with X-ray Lasers

    DOE PAGES

    Sun, Zhibin; Fan, Jiadong; Li, Haoyuan; ...

    2018-01-22

    The advent of ultrafast X-ray free-electron lasers (XFELs) opens the tantalizing possibility of the atomic-resolution imaging of reproducible objects such as viruses, nanoparticles, single molecules, clusters, and perhaps biological cells, achieving a resolution for single particle imaging better than a few tens of nanometers. Improving upon this is a significant challenge which has been the focus of a global single particle imaging (SPI) initiative launched in December 2014 at the Linac Coherent Light Source (LCLS), SLAC National Accelerator Laboratory, USA. A roadmap was outlined, and significant multi-disciplinary effort has since been devoted to work on the technical challenges of SPImore » such as radiation damage, beam characterization, beamline instrumentation and optics, sample preparation and delivery and algorithm development at multiple institutions involved in the SPI initiative. Currently, the SPI initiative has achieved 3D imaging of rice dwarf virus (RDV) and coliphage PR772 viruses at ~10 nm resolution by using soft X-ray FEL pulses at the Atomic Molecular and Optical (AMO) instrument of LCLS. Meanwhile, diffraction patterns with signal above noise up to the corner of the detector with a resolution of ~6 Ångström (Å) were also recorded with hard X-rays at the Coherent X-ray Imaging (CXI) instrument, also at LCLS. Achieving atomic resolution is truly a grand challenge and there is still a long way to go in light of recent developments in electron microscopy. However, the potential for studying dynamics at physiological conditions and capturing ultrafast biological, chemical and physical processes represents a tremendous potential application, attracting continued interest in pursuing further method development. In this paper, we give a brief introduction of SPI developments and look ahead to further method development.« less

  12. Current Status of Single Particle Imaging with X-ray Lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Zhibin; Fan, Jiadong; Li, Haoyuan

    The advent of ultrafast X-ray free-electron lasers (XFELs) opens the tantalizing possibility of the atomic-resolution imaging of reproducible objects such as viruses, nanoparticles, single molecules, clusters, and perhaps biological cells, achieving a resolution for single particle imaging better than a few tens of nanometers. Improving upon this is a significant challenge which has been the focus of a global single particle imaging (SPI) initiative launched in December 2014 at the Linac Coherent Light Source (LCLS), SLAC National Accelerator Laboratory, USA. A roadmap was outlined, and significant multi-disciplinary effort has since been devoted to work on the technical challenges of SPImore » such as radiation damage, beam characterization, beamline instrumentation and optics, sample preparation and delivery and algorithm development at multiple institutions involved in the SPI initiative. Currently, the SPI initiative has achieved 3D imaging of rice dwarf virus (RDV) and coliphage PR772 viruses at ~10 nm resolution by using soft X-ray FEL pulses at the Atomic Molecular and Optical (AMO) instrument of LCLS. Meanwhile, diffraction patterns with signal above noise up to the corner of the detector with a resolution of ~6 Ångström (Å) were also recorded with hard X-rays at the Coherent X-ray Imaging (CXI) instrument, also at LCLS. Achieving atomic resolution is truly a grand challenge and there is still a long way to go in light of recent developments in electron microscopy. However, the potential for studying dynamics at physiological conditions and capturing ultrafast biological, chemical and physical processes represents a tremendous potential application, attracting continued interest in pursuing further method development. In this paper, we give a brief introduction of SPI developments and look ahead to further method development.« less

  13. Sonographic Findings in Necrotizing Fasciitis: Two Ends of the Spectrum.

    PubMed

    Shyy, William; Knight, Roneesha S; Goldstein, Ruth; Isaacs, Eric D; Teismann, Nathan A

    2016-10-01

    Necrotizing fasciitis is a rare but serious disease, and early diagnosis is essential to reducing its substantial morbidity and mortality. The 2 cases presented show that the key clinical and radiographic features of necrotizing fasciitis exist along a continuum of severity at initial presentation; thus, this diagnosis should not be prematurely ruled out in cases that do not show the dramatic features familiar to most clinicians. Although computed tomography and magnetic resonance imaging are considered the most effective imaging modalities, the cases described here illustrate how sonography should be recommended as an initial imaging test to make a rapid diagnosis and initiate therapy.

  14. Imaging and Data Acquisition in Clinical Trials for Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    FitzGerald, Thomas J., E-mail: Thomas.Fitzgerald@umassmed.edu; Bishop-Jodoin, Maryann; Followill, David S.

    2016-02-01

    Cancer treatment evolves through oncology clinical trials. Cancer trials are multimodal and complex. Assuring high-quality data are available to answer not only study objectives but also questions not anticipated at study initiation is the role of quality assurance. The National Cancer Institute reorganized its cancer clinical trials program in 2014. The National Clinical Trials Network (NCTN) was formed and within it was established a Diagnostic Imaging and Radiation Therapy Quality Assurance Organization. This organization is Imaging and Radiation Oncology Core, the Imaging and Radiation Oncology Core Group, consisting of 6 quality assurance centers that provide imaging and radiation therapy qualitymore » assurance for the NCTN. Sophisticated imaging is used for cancer diagnosis, treatment, and management as well as for image-driven technologies to plan and execute radiation treatment. Integration of imaging and radiation oncology data acquisition, review, management, and archive strategies are essential for trial compliance and future research. Lessons learned from previous trials are and provide evidence to support diagnostic imaging and radiation therapy data acquisition in NCTN trials.« less

  15. Dual Energy Tomosynthesis breast phantom imaging

    NASA Astrophysics Data System (ADS)

    Koukou, V.; Martini, N.; Fountos, G.; Messaris, G.; Michail, C.; Kandarakis, I.; Nikiforidis, G.

    2017-12-01

    Dual energy (DE) imaging technique has been applied to many theoretical and experimental studies. The aim of the current study is to evaluate dual energy in breast tomosynthesis using commercial tomosynthesis system in terms of its potential to better visualize microcalcifications (μCs). The system uses a tungsten target X-ray tube and a selenium direct conversion detector. Low-energy (LE) images were acquired at different tube voltages (28, 30, 32 kV), while high-energy images at 49 kV. Fifteen projections, for the low- and high-energy respectively, were acquired without grid while tube scanned continuously. Log-subtraction algorithm was used in order to obtain the DE images with the weighting factor, w, derived empirically. The subtraction was applied to each pair of LE and HE slices after reconstruction. The TORMAM phantom was imaged with the different settings. Four regions-of-interest including μCs were identified in the inhomogeneous part of the phantom. The μCs in DE images were more clearly visible compared to the low-energy images. Initial results showed that DE tomosynthesis imaging is a promising modality, however more work is required.

  16. 7 T renal MRI: challenges and promises.

    PubMed

    de Boer, Anneloes; Hoogduin, Johannes M; Blankestijn, Peter J; Li, Xiufeng; Luijten, Peter R; Metzger, Gregory J; Raaijmakers, Alexander J E; Umutlu, Lale; Visser, Fredy; Leiner, Tim

    2016-06-01

    The progression to 7 Tesla (7 T) magnetic resonance imaging (MRI) yields promises of substantial increase in signal-to-noise (SNR) ratio. This increase can be traded off to increase image spatial resolution or to decrease acquisition time. However, renal 7 T MRI remains challenging due to inhomogeneity of the radiofrequency field and due to specific absorption rate (SAR) constraints. A number of studies has been published in the field of renal 7 T imaging. While the focus initially was on anatomic imaging and renal MR angiography, later studies have explored renal functional imaging. Although anatomic imaging remains somewhat limited by inhomogeneous excitation and SAR constraints, functional imaging results are promising. The increased SNR at 7 T has been particularly advantageous for blood oxygen level-dependent and arterial spin labelling MRI, as well as sodium MR imaging, thanks to changes in field-strength-dependent magnetic properties. Here, we provide an overview of the currently available literature on renal 7 T MRI. In addition, we provide a brief overview of challenges and opportunities in renal 7 T MR imaging.

  17. Initial clinical evaluation of stationary digital chest tomosynthesis

    NASA Astrophysics Data System (ADS)

    Hartman, Allison E.; Shan, Jing; Wu, Gongting; Lee, Yueh Z.; Zhou, Otto; Lu, Jianping; Heath, Michael; Wang, Xiaohui; Foos, David

    2016-03-01

    Computed Tomography (CT) is the gold standard for image evaluation of lung disease, including lung cancer and cystic fibrosis. It provides detailed information of the lung anatomy and lesions, but at a relatively high cost and high dose of radiation. Chest radiography is a low dose imaging modality but it has low sensitivity. Digital chest tomosynthesis (DCT) is an imaging modality that produces 3D images by collecting x-ray projection images over a limited angle. DCT is less expensive than CT and requires about 1/10th the dose of radiation. Commercial DCT systems acquire the projection images by mechanically scanning an x-ray tube. The movement of the tube head limits acquisition speed. We recently demonstrated the feasibility of stationary digital chest tomosynthesis (s-DCT) using a carbon nanotube (CNT) x-ray source array in benchtop phantom studies. The stationary x-ray source allows for fast image acquisition. The objective of this study is to demonstrate the feasibility of s-DCT for patient imaging. We have successfully imaged 31 patients. Preliminary evaluation by board certified radiologists suggests good depiction of thoracic anatomy and pathology.

  18. Simulation of Image Performance Characteristics of the Landsat Data Continuity Mission (LDCM) Thermal Infrared Sensor (TIRS)

    NASA Technical Reports Server (NTRS)

    Schott, John; Gerace, Aaron; Brown, Scott; Gartley, Michael; Montanaro, Matthew; Reuter, Dennis C.

    2012-01-01

    The next Landsat satellite, which is scheduled for launch in early 2013, will carry two instruments: the Operational Land Imager (OLI) and the Thermal Infrared Sensor (TIRS). Significant design changes over previous Landsat instruments have been made to these sensors to potentially enhance the quality of Landsat image data. TIRS, which is the focus of this study, is a dual-band instrument that uses a push-broom style architecture to collect data. To help understand the impact of design trades during instrument build, an effort was initiated to model TIRS imagery. The Digital Imaging and Remote Sensing Image Generation (DIRSIG) tool was used to produce synthetic "on-orbit" TIRS data with detailed radiometric, geometric, and digital image characteristics. This work presents several studies that used DIRSIG simulated TIRS data to test the impact of engineering performance data on image quality in an effort to determine if the image data meet specifications or, in the event that they do not, to determine if the resulting image data are still acceptable.

  19. Modified tandem gratings anastigmatic imaging spectrometer with oblique incidence for spectral broadband

    NASA Astrophysics Data System (ADS)

    Cui, Chengguang; Wang, Shurong; Huang, Yu; Xue, Qingsheng; Li, Bo; Yu, Lei

    2015-09-01

    A modified spectrometer with tandem gratings that exhibits high spectral resolution and imaging quality for solar observation, monitoring, and understanding of coastal ocean processes is presented in this study. Spectral broadband anastigmatic imaging condition, spectral resolution, and initial optical structure are obtained based on geometric aberration theory. Compared with conventional tandem gratings spectrometers, this modified design permits flexibility in selecting gratings. A detailed discussion of the optical design and optical performance of an ultraviolet spectrometer with tandem gratings is also included to explain the advantage of oblique incidence for spectral broadband.

  20. Thermal imaging of afterburning plumes

    NASA Astrophysics Data System (ADS)

    Ajdari, E.; Gutmark, E.; Parr, T. P.; Wilson, K. J.; Schadow, K. C.

    1989-01-01

    Afterburning and nonafterburning exhaust plumes were studied experimentally for underexpanded sonic and supersonic conical circular nozzles. The plume structure was visualized using thermal imaging camera and regular photography. IR emission by the plume is mainly dependent on the presence of afterburning. Temperature and reducing power of the exhaust gases, in addition to the nozzle configuration, determine the structure of the plume core, the location where the afterburning is initiated, its size and intensity. Comparison between single shot and average thermal images of the plume show that afterburning is a highly turbulent combustion process.

  1. Status report: Data management program algorithm evaluation activity at Marshall Space Flight Center

    NASA Technical Reports Server (NTRS)

    Jayroe, R. R., Jr.

    1977-01-01

    An algorithm evaluation activity was initiated to study the problems associated with image processing by assessing the independent and interdependent effects of registration, compression, and classification techniques on LANDSAT data for several discipline applications. The objective of the activity was to make recommendations on selected applicable image processing algorithms in terms of accuracy, cost, and timeliness or to propose alternative ways of processing the data. As a means of accomplishing this objective, an Image Coding Panel was established. The conduct of the algorithm evaluation is described.

  2. International Cognition and Cancer Task Force Recommendations for Neuroimaging Methods in the Study of Cognitive Impairment in Non-CNS Cancer Patients.

    PubMed

    Deprez, Sabine; Kesler, Shelli R; Saykin, Andrew J; Silverman, Daniel H S; de Ruiter, Michiel B; McDonald, Brenna C

    2018-03-01

    Cancer- and treatment-related cognitive changes have been a focus of increasing research since the early 1980s, with meta-analyses demonstrating poorer performance in cancer patients in cognitive domains including executive functions, processing speed, and memory. To facilitate collaborative efforts, in 2011 the International Cognition and Cancer Task Force (ICCTF) published consensus recommendations for core neuropsychological tests for studies of cancer populations. Over the past decade, studies have used neuroimaging techniques, including structural and functional magnetic resonance imaging (fMRI) and positron emission tomography, to examine the underlying brain basis for cancer- and treatment-related cognitive declines. As yet, however, there have been no consensus recommendations to guide researchers new to this field or to promote the ability to combine data sets. We first discuss important methodological issues with regard to neuroimaging study design, scanner considerations, and sequence selection, focusing on concerns relevant to cancer populations. We propose a minimum recommended set of sequences, including a high-resolution T1-weighted volume and a resting state fMRI scan. Additional advanced imaging sequences are discussed for consideration when feasible, including task-based fMRI and diffusion tensor imaging. Important image data processing and analytic considerations are also reviewed. These recommendations are offered to facilitate increased use of neuroimaging in studies of cancer- and treatment-related cognitive dysfunction. They are not intended to discourage investigator-initiated efforts to develop cutting-edge techniques, which will be helpful in advancing the state of the knowledge. Use of common imaging protocols will facilitate multicenter and data-pooling initiatives, which are needed to address critical mechanistic research questions.

  3. Observation of Intravascular Changes of Superabsorbent Polymer Microsphere (SAP-MS) with Monochromatic X-Ray Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanimoto, Daigo, E-mail: daigoro@med.kawasaki-m.ac.jp; Ito, Katsuyoshi; Yamamoto, Akira

    2010-10-15

    This study was designed to evaluate the intravascular transformation behavior of superabsorbent polymer microsphere (SAP-MS) in vivo macroscopically by using monochromatic X-ray imaging and to quantitatively compare the expansion rate of SAP-MS among different kinds of mixtures. Fifteen rabbits were used for our study and transcatheter arterial embolization (TAE) was performed for their auricular arteries using monochromatic X-ray imaging. We used three kinds of SAP-MS (particle diameter 100-150 {mu}m) mixture as embolic spherical particles: SAP-MS(H) absorbed with sodium meglumine ioxaglate (Hexabrix 320), SAP-MS(V) absorbed with isosmolar contrast medium (Visipaque 270), and SAP-MS(S) absorbed with 0.9% sodium saline. The initial volumemore » of SAP-MS particles just after TAE and its final volume 10 minutes after TAE in the vessel were measured to calculate the expansion rate (ER) (n = 30). Intravascular behavior of SAP-MS particles was clearly observed in real time at monochromatic X-ray imaging. Averaged initial volumes of SAP-MS (H) (1.24 x 10{sup 7} {mu}m{sup 3}) were significantly smaller (p < 0.001) than those of SAP-MS (V) (5.99 x 10{sup 7} {mu}m{sup 3}) and SAP-MS (S) (5.85 x 10{sup 7} {mu}m{sup 3}). Averaged final volumes of SAP-MS (H) were significantly larger than averaged initial volumes (4.41 x 10{sup 7} {mu}m{sup 3} vs. 1.24 x 10{sup 7} {mu}m{sup 3}; p < 0.0001, ER = 3.55). There were no significant difference between averaged final volumes and averaged initial volumes of SAP-MS (V) and SAP-MS (S). SAP-MS (H), which first travels distally, reaches to small arteries, and then expands to adapt to the vessel lumen, is an effective particle as an embolic agent, causing effective embolization.« less

  4. A Foundation for Enterprise Imaging: HIMSS-SIIM Collaborative White Paper.

    PubMed

    Roth, Christopher J; Lannum, Louis M; Persons, Kenneth R

    2016-10-01

    Care providers today routinely obtain valuable clinical multimedia with mobile devices, scope cameras, ultrasound, and many other modalities at the point of care. Image capture and storage workflows may be heterogeneous across an enterprise, and as a result, they often are not well incorporated in the electronic health record. Enterprise Imaging refers to a set of strategies, initiatives, and workflows implemented across a healthcare enterprise to consistently and optimally capture, index, manage, store, distribute, view, exchange, and analyze all clinical imaging and multimedia content to enhance the electronic health record. This paper is intended to introduce Enterprise Imaging as an important initiative to clinical and informatics leadership, and outline its key elements of governance, strategy, infrastructure, common multimedia content, acquisition workflows, enterprise image viewers, and image exchange services.

  5. A new watermarking approach based on combination of reversible watermarking and CDMA in spatial and DWT domain

    NASA Astrophysics Data System (ADS)

    Bekkouche, S.; Chouarfia, A.

    2011-06-01

    Image watermarking can be defined as a technique that allows insertion of imperceptible and indelible digital data into an image. In addition to its initial application which is the copyright, watermarking can be used in other fields, particularly in the medical field in order to contribute to secure images shared on the network for telemedicine applications. In this report we study some watermarking methods and the comparison result of their combination, the first one is based on the CDMA (Code Division Multiple Access) in DWT and spatial domain and its aim is to verify the image authenticity whereas the second one is the reversible watermarking (the least significant bits LSB and cryptography tools) and the reversible contrast mapping RCM its objective is to check the integrity of the image and to keep the Confidentiality of the patient data. A new scheme of watermarking is the combination of the reversible watermarking method based on LSB and cryptography tools and the method of CDMA in spatial and DWT domain to verify the three security properties Integrity, Authenticity and confidentiality of medical data and patient information .In the end ,we made a comparison between these methods within the parameters of quality of medical images. Initially, an in-depth study on the characteristics of medical images would contribute to improve these methods to mitigate their limits and to optimize the results. Tests were done on IRM kind of medical images and the quality measurements have been done on the watermarked image to verify that this technique does not lead to a wrong diagnostic. The robustness of the watermarked images against attacks has been verified on the parameters of PSNR, SNR, MSE and MAE which the experimental result demonstrated that the proposed algorithm is good and robust in DWT than in spatial domain.

  6. Success rate and risk factors for failure of empirical antifungal therapy with itraconazole in patients with hematological malignancies: a multicenter, prospective, open-label, observational study in Korea.

    PubMed

    Kim, Soo-Jeong; Cheong, June-Won; Min, Yoo Hong; Choi, Young Jin; Lee, Dong-Gun; Lee, Je-Hwan; Yang, Deok-Hwan; Lee, Sang Min; Kim, Sung-Hyun; Kim, Yang Soo; Kwak, Jae-Yong; Park, Jinny; Kim, Jin Young; Kim, Hoon-Gu; Kim, Byung Soo; Ryoo, Hun-Mo; Jang, Jun Ho; Kim, Min Kyoung; Kang, Hye Jin; Cho, In Sung; Mun, Yeung Chul; Jo, Deog-Yeon; Kim, Ho Young; Park, Byeong-Bae; Kim, Jin Seok

    2014-01-01

    We assessed the success rate of empirical antifungal therapy with itraconazole and evaluated risk factors for predicting the failure of empirical antifungal therapy. A multicenter, prospective, observational study was performed in patients with hematological malignancies who had neutropenic fever and received empirical antifungal therapy with itraconazole at 22 centers. A total of 391 patients who had abnormal findings on chest imaging tests (31.0%) or a positive result of enzyme immunoassay for serum galactomannan (17.6%) showed a 56.5% overall success rate. Positive galactomannan tests before the initiation of the empirical antifungal therapy (P=0.026, hazard ratio [HR], 2.28; 95% confidence interval [CI], 1.10-4.69) and abnormal findings on the chest imaging tests before initiation of the empirical antifungal therapy (P=0.022, HR, 2.03; 95% CI, 1.11-3.71) were significantly associated with poor outcomes for the empirical antifungal therapy. Eight patients (2.0%) had premature discontinuation of itraconazole therapy due to toxicity. It is suggested that positive galactomannan tests and abnormal findings on the chest imaging tests at the time of initiation of the empirical antifungal therapy are risk factors for predicting the failure of the empirical antifungal therapy with itraconazole. (Clinical Trial Registration on National Cancer Institute website, NCT01060462).

  7. Reversible lesions in the brain parenchyma in Wilson's disease confirmed by magnetic resonance imaging: earlier administration of chelating therapy can reduce the damage to the brain.

    PubMed

    Kozić, Duško B; Petrović, Igor; Svetel, Marina; Pekmezović, Tatjana; Ragaji, Aleksandar; Kostić, Vladimir S

    2014-11-01

    The aim of this study was to evaluate the resolution of brain lesions in patients with Wilson's disease during the long-term chelating therapy using magnetic resonance imaging and a possible significance of the time latency between the initial symptoms of the disease and the introduction of this therapy. Initial magnetic resonance examination was performed in 37 patients with proven neurological form of Wilson's disease with cerebellar, parkinsonian and dystonic presentation. Magnetic resonance reexamination was done 5.7 ± 1.3 years later in 14 patients. Patients were divided into: group A, where chelating therapy was initiated < 24 months from the first symptoms and group B, where the therapy started ≥ 24 months after the initial symptoms. Symmetry of the lesions was seen in 100% of patients. There was a significant difference between groups A and B regarding complete resolution of brain stem and putaminal lesions (P = 0.005 and P = 0.024, respectively). If the correct diagnosis and adequate treatment are not established less than 24 months after onset of the symptoms, irreversible lesions in the brain parenchyma could be expected. Signal abnormalities on magnetic resonance imaging might therefore, at least in the early stages, represent reversible myelinolisis or cytotoxic edema associated with copper toxicity.

  8. Lumbar disc herniation in young children.

    PubMed

    Haidar, R; Ghanem, I; Saad, S; Uthman, I

    2010-01-01

    This article explores lumbar disc herniation in young children through focusing on matters relevant to patient presentation, physical examination, differential diagnosis, imaging and treatment. Major databases were searched for studies that addressed lumbar disc herniation in young children. Diagnosis of lumbar disc herniation in young children is usually delayed because of the rarity and lack of experience with this entity and the difficulty in extracting a reliable medical history. Nevertheless, lumbar disc herniation should be considered in the differential diagnosis of any young child presenting with a chief complaint of back pain and/or radiculopathy, especially in the setting of recent trauma. This should be coupled with a directed physical examination to elicit signs and narrow the differential diagnosis. Imaging studies, mainly magnetic resonance imaging, will help establish a diagnosis; yet radiographs are still required to exclude other spinal lesions. The initial management of lumbar disc herniation in children is the same as that in adults and consists of conservative treatment unless lumbar disc herniation affects the patient's motor and neurological functions in which case, early surgical treatment must be undertaken. Although the latter remains more difficult, current experience suggests a favourable outcome. Awareness of lumbar disc herniation will help the paediatrician extract a relevant medical history, perform a directed physical examination, and order appropriate imaging studies. This will aid in initiating early intervention, be it conservative or operative, and achieving a favourable outcome.

  9. Investigation of nucleation and growth processes of diamond films by atomic force microscopy

    NASA Technical Reports Server (NTRS)

    George, M. A.; Burger, A.; Collins, W. E.; Davidson, J. L.; Barnes, A. V.; Tolk, N. H.

    1994-01-01

    The nucleation and growth of plasma-enhanced chemical-vapor deposited polycrystalline diamond films were studied using atomic force microscopy (AFM). AFM images were obtained for (1) nucleated diamond films produced from depositions that were terminated during the initial stages of growth, (2) the silicon substrate-diamond film interface side of diamond films (1-4 micrometers thick) removed from the original surface of the substrate, and (3) the cross-sectional fracture surface of the film, including the Si/diamond interface. Pronounced tip effects were observed for early-stage diamond nucleation attributed to tip convolution in the AFM images. AFM images of the film's cross section and interface, however, were not highly affected by tip convolution, and the images indicate that the surface of the silicon substrate is initially covered by a small grained polycrystalline-like film and the formation of this precursor film is followed by nucleation of the diamond film on top of this layer. X-ray photoelectron spectroscopy spectra indicate that some silicon carbide is present in the precursor layer.

  10. Impact of an evidence-based guideline on the management of community-acquired bacterial meningitis: a prospective cohort study.

    PubMed

    Costerus, J M; Brouwer, M C; Bijlsma, M W; Tanck, M W; van der Ende, A; van de Beek, D

    2016-11-01

    To study the impact of an evidence-based guideline on the management of community-acquired bacterial meningitis. We performed an interrupted time series analysis in a prospective nationwide cohort study from 2006 to 2015. The guideline stresses the importance of cranial imaging before lumbar puncture (LP) in selected patients based on clinical criteria, and early treatment with amoxicillin and a third-generation cephalosporin for adults with suspected community-acquired bacterial meningitis. The guideline was published in April 2013. We included 1326 episodes before and 210 episodes after guideline introduction. Cranial imaging was performed before LP in 497 (84%) of 591 episodes with clinical criteria warranting computed tomography (CT). The guideline did not improve this (increase of 2%; 95% confidence interval (CI), -15 to 19). Without these criteria, imaging before LP occurred in 606 (67%) of 900 episodes, also without effect of the guideline (increase of 1%; 95% CI, -25 to 28). The estimate of effect of the guideline for treatment with the recommended antibiotic regimen was an increase of 19.5% (95% CI, 13.5 to 25.5), and there was a trend towards more frequent initiation of treatment before CT. There was no association between delay in antibiotic treatment due to imaging before LP and unfavourable outcome (odds ratio, 1.14; 95% CI 0.86 to 1.52). Cranial imaging is performed before LP in the majority of patients with bacterial meningitis, irrespective of guideline indications. The guideline introduction was associated with a trend towards early initiation of treatment before imaging and with increased adherence to antibiotic policy. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  11. Missed rib fractures on evaluation of initial chest CT for trauma patients: pattern analysis and diagnostic value of coronal multiplanar reconstruction images with multidetector row CT.

    PubMed

    Cho, S H; Sung, Y M; Kim, M S

    2012-10-01

    The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images.

  12. Tests of the Grobner Basis Solution for Lightning Ground Flash Fraction Retrieval

    NASA Technical Reports Server (NTRS)

    Koshak, William; Solakiewicz, Richard; Attele, Rohan

    2011-01-01

    Satellite lightning imagers such as the NASA Tropical Rainfall Measuring Mission Lightning Imaging Sensor (TRMM/LIS) and the future GOES-R Geostationary Lightning Mapper (GLM) are designed to detect total lightning (ground flashes + cloud flashes). However, there is a desire to discriminate ground flashes from cloud flashes from the vantage point of space since this would enhance the overall information content of the satellite lightning data and likely improve its operational and scientific applications (e.g., in severe weather warning, lightning nitrogen oxides studies, and global electric circuit analyses). A Bayesian inversion method was previously introduced for retrieving the fraction of ground flashes in a set of flashes observed from a satellite lightning imager. The method employed a constrained mixed exponential distribution model to describe the lightning optical measurements. To obtain the optimum model parameters (one of which is the ground flash fraction), a scalar function was minimized by a numerical method. In order to improve this optimization, a Grobner basis solution was introduced to obtain analytic representations of the model parameters that serve as a refined initialization scheme to the numerical optimization. In this study, we test the efficacy of the Grobner basis initialization using actual lightning imager measurements and ground flash truth derived from the national lightning network.

  13. A feasibility study on estimation of tissue mixture contributions in 3D arterial spin labeling sequence

    NASA Astrophysics Data System (ADS)

    Liu, Yang; Pu, Huangsheng; Zhang, Xi; Li, Baojuan; Liang, Zhengrong; Lu, Hongbing

    2017-03-01

    Arterial spin labeling (ASL) provides a noninvasive measurement of cerebral blood flow (CBF). Due to relatively low spatial resolution, the accuracy of CBF measurement is affected by the partial volume (PV) effect. To obtain accurate CBF estimation, the contribution of each tissue type in the mixture is desirable. In general, this can be obtained according to the registration of ASL and structural image in current ASL studies. This approach can obtain probability of each tissue type inside each voxel, but it also introduces error, which include error of registration algorithm and imaging itself error in scanning of ASL and structural image. Therefore, estimation of mixture percentage directly from ASL data is greatly needed. Under the assumption that ASL signal followed the Gaussian distribution and each tissue type is independent, a maximum a posteriori expectation-maximization (MAP-EM) approach was formulated to estimate the contribution of each tissue type to the observed perfusion signal at each voxel. Considering the sensitivity of MAP-EM to the initialization, an approximately accurate initialization was obtain using 3D Fuzzy c-means method. Our preliminary results demonstrated that the GM and WM pattern across the perfusion image can be sufficiently visualized by the voxel-wise tissue mixtures, which may be promising for the diagnosis of various brain diseases.

  14. The association between continuous antibiotic prophylaxis and UTI from birth until initial postnatal imaging evaluation among newborns with antenatal hydronephrosis.

    PubMed

    Varda, B K; Finkelstein, J B; Wang, H-H; Logvinenko, T; Nelson, C P

    2018-05-29

    There is a lack of consensus regarding the use of continuous antibiotic prophylaxis (CAP) during the interval between birth and initial postnatal imaging in infants with a history of antenatal urinary tract dilation (AUTD). To determine the incidence of urinary tract infection (UTI), and the association between CAP use and UTI during the interval between birth and the first postnatal renal ultrasound (RUS) in infants with AUTD. A single-institution, retrospective cohort study of newborns with a history of AUTD. Infants undergoing RUS within 3 months of birth for an indication of 'hydronephrosis' between 2012 and 2014 were identified. A random sample of 500 infants was selected; six were excluded for concomitant congenital anomalies. Baseline patient (sex, race, insurance) and clinical characteristics (circumcision status, UTD risk score, receipt of CAP, UTI prior to RUS, age at UTI, and age at RUS) were collected via retrospective chart review. Descriptive statistics were calculated. To adjust for receipt of CAP, propensity score adjusted univariate logistic regression for UTI based on CAP status was performed. Among the 494 infants with AUTD, 157 (32%) received CAP. Infants with normal/low-risk UTD scores were less likely to receive CAP than those with medium/high-risk UTD (23% vs 77%; P < 0.001). There was no difference in CAP based on sex, insurance, or circumcision status (among 260/365 males with known circumcision status). Overall, seven infants (1.4%) developed UTI prior to imaging: six (1.8%) without CAP vs one (0.64%) with CAP (P = 0.44). The median age at UTI was 59 days (range 2-84); among those with UTI, initial imaging occurred significantly later (66 vs 28 days; P = 0.001). The propensity score adjusted odds of developing UTI with CAP (vs without) was 0.93 (95% CI 0.10-8.32; P = 0.95). The Summary Figure describes the infants with UTI. The incidence of UTI prior to initial neonatal imaging in newborns with AUTD was low. Use of CAP was not associated with UTI incidence after adjusting for UTD severity. Routine use of CAP in newborns with AUTD prior to initial imaging may be of limited benefit in most patients. Copyright © 2018 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  15. Effects of a Body Image Challenge on Smoking Motivation Among College Females

    PubMed Central

    Lopez, Elena N.; Drobes, David J.; Thompson, J. Kevin; Brandon, Thomas H.

    2014-01-01

    Objective Previous correlational and quasi-experimental research has established that weight concerns and negative body image are associated with tobacco smoking, cessation, and relapse, particularly among young women. This study examined the causal influence of body image upon smoking motivation by merging methodologies from the addiction and body image literatures. Design Using a cue-reactivity paradigm, the study tested whether an experimental manipulation designed to challenge women’s body image—specifically, their weight dissatisfaction—influenced their motivation to smoke. Female college smokers (N = 62) were included in a 2 × 2 factorial, within-subjects design (body image cues X smoking cues). Main Outcome Measures Self-reported urge to smoke was the primary dependent measure, with skin conductance as a secondary measure. Results As hypothesized, the presentation of smoking images and thin model images produced greater urges to smoke than control images. Additionally, trait weight concerns moderated the effect of the body image manipulation such that those women with greater weight concerns produced greater craving to the thin model image (when smoking cues were not present). Conclusion These findings provide initial evidence that situational challenges to body image are causally related to smoking motivation. PMID:18979977

  16. Initial phantom study comparing image quality in computed tomography using adaptive statistical iterative reconstruction and new adaptive statistical iterative reconstruction v.

    PubMed

    Lim, Kyungjae; Kwon, Heejin; Cho, Jinhan; Oh, Jongyoung; Yoon, Seongkuk; Kang, Myungjin; Ha, Dongho; Lee, Jinhwa; Kang, Eunju

    2015-01-01

    The purpose of this study was to assess the image quality of a novel advanced iterative reconstruction (IR) method called as "adaptive statistical IR V" (ASIR-V) by comparing the image noise, contrast-to-noise ratio (CNR), and spatial resolution from those of filtered back projection (FBP) and adaptive statistical IR (ASIR) on computed tomography (CT) phantom image. We performed CT scans at 5 different tube currents (50, 70, 100, 150, and 200 mA) using 3 types of CT phantoms. Scanned images were subsequently reconstructed in 7 different scan settings, such as FBP, and 3 levels of ASIR and ASIR-V (30%, 50%, and 70%). The image noise was measured in the first study using body phantom. The CNR was measured in the second study using contrast phantom and the spatial resolutions were measured in the third study using a high-resolution phantom. We compared the image noise, CNR, and spatial resolution among the 7 reconstructed image scan settings to determine whether noise reduction, high CNR, and high spatial resolution could be achieved at ASIR-V. At quantitative analysis of the first and second studies, it showed that the images reconstructed using ASIR-V had reduced image noise and improved CNR compared with those of FBP and ASIR (P < 0.001). At qualitative analysis of the third study, it also showed that the images reconstructed using ASIR-V had significantly improved spatial resolution than those of FBP and ASIR (P < 0.001). Our phantom studies showed that ASIR-V provides a significant reduction in image noise and a significant improvement in CNR as well as spatial resolution. Therefore, this technique has the potential to reduce the radiation dose further without compromising image quality.

  17. Analysis of ROC on chest direct digital radiography (DR) after image processing in diagnosis of SARS

    NASA Astrophysics Data System (ADS)

    Lv, Guozheng; Lan, Rihui; Zeng, Qingsi; Zheng, Zhong

    2004-05-01

    The Severe Acute Respiratory Syndrome (SARS, also called Infectious Atypical Pneumonia), which initially broke out in late 2002, has threatened the public"s health seriously. How to confirm the patients contracting SARS becomes an urgent issue in diagnosis. This paper intends to evaluate the importance of Image Processing in the diagnosis on SARS at the early stage. Receiver Operating Characteristics (ROC) analysis has been employed in this study to compare the value of DR images in the diagnosis of SARS patients before and after image processing by Symphony Software supplied by E-Com Technology Ltd., and DR image study of 72 confirmed or suspected SARS patients were reviewed respectively. All the images taken from the studied patients were processed by Symphony. Both the original and processed images were taken into ROC analysis, based on which the ROC graph for each group of images has been produced as described below: For processed images: a = 1.9745, b = 1.4275, SA = 0.8714; For original images: a = 0.9066, b = 0.8310, SA = 0.7572; (a - intercept, b - slop, SA - Area below the curve). The result shows significant difference between the original images and processed images (P<0.01). In summary, the images processed by Symphony are superior to the original ones in detecting the opacity lesion, and increases the accuracy of SARS diagnosis.

  18. Geological terrain models

    NASA Technical Reports Server (NTRS)

    Kaupp, V. H.; Macdonald, H. C.; Waite, W. P.

    1981-01-01

    The initial phase of a program to determine the best interpretation strategy and sensor configuration for a radar remote sensing system for geologic applications is discussed. In this phase, terrain modeling and radar image simulation were used to perform parametric sensitivity studies. A relatively simple computer-generated terrain model is presented, and the data base, backscatter file, and transfer function for digital image simulation are described. Sets of images are presented that simulate the results obtained with an X-band radar from an altitude of 800 km and at three different terrain-illumination angles. The simulations include power maps, slant-range images, ground-range images, and ground-range images with statistical noise incorporated. It is concluded that digital image simulation and computer modeling provide cost-effective methods for evaluating terrain variations and sensor parameter changes, for predicting results, and for defining optimum sensor parameters.

  19. Adaptive optics image restoration algorithm based on wavefront reconstruction and adaptive total variation method

    NASA Astrophysics Data System (ADS)

    Li, Dongming; Zhang, Lijuan; Wang, Ting; Liu, Huan; Yang, Jinhua; Chen, Guifen

    2016-11-01

    To improve the adaptive optics (AO) image's quality, we study the AO image restoration algorithm based on wavefront reconstruction technology and adaptive total variation (TV) method in this paper. Firstly, the wavefront reconstruction using Zernike polynomial is used for initial estimated for the point spread function (PSF). Then, we develop our proposed iterative solutions for AO images restoration, addressing the joint deconvolution issue. The image restoration experiments are performed to verify the image restoration effect of our proposed algorithm. The experimental results show that, compared with the RL-IBD algorithm and Wiener-IBD algorithm, we can see that GMG measures (for real AO image) from our algorithm are increased by 36.92%, and 27.44% respectively, and the computation time are decreased by 7.2%, and 3.4% respectively, and its estimation accuracy is significantly improved.

  20. Plain radiologic findings and chronological changes of incipient phase osteosarcoma overlooked by primary physicians.

    PubMed

    Song, Won Seok; Jeon, Dae-Geun; Cho, Wan Hyeong; Kong, Chang-Bae; Cho, Sang Hyun; Lee, Jung Wook; Lee, Soo-Yong

    2014-06-01

    We assessed the plain radiographic characteristics of 10 cases of osteosarcomas during the initial painful period that had been overlooked by a primary physician. In addition, we evaluated chronologic changes in radiographic findings from initial symptomatic period to the time of accurate diagnosis. The clinical records were reviewed for clinical parameters including age, sex, location, presenting symptoms, initial diagnosis, duration from initial symptoms to definite diagnosis, and initial and follow-up plain radiographic findings of the lesion. Initial clinical diagnoses included a sprain in 6, growing pain in 2, stress fracture in 1, and infection in 1 patient. Initial plain radiographic findings were trabecular destruction (100%), cortical disruption (60%), periosteal reaction (60%), and soft tissue mass (10%). Intramedullary matrix changes were osteosclerosis in 6 and osteolysis in 4 patients. On progression, 4 cases with minimal sclerosis changed to osteoblastic lesion in 3 patients and osteolytic lesion in 1. Four cases with faint osteolytic foci transformed into osteolytic lesion in 3 and mixed pattern in 1. Notable plain radiologic findings of incipient-stage osteosarcoma include trabecular disruption along with faint osteosclerosis or osteolysis. In symptomatic patients with trabecular destruction, additional imaging study including magnetic resonance imaging should be performed to exclude osteosarcoma in the incipient phase, even without radiologic findings suggesting malignant tumor, such as cortical destruction or periosteal reaction.

  1. A Study of Imaging Interferometer Simulators

    NASA Technical Reports Server (NTRS)

    Allen, Ronald J.

    2002-01-01

    Several new space science mission concepts under development at NASA-GSFC for astronomy are intended to carry out synthetic imaging using Michelson interferometers or direct (Fizeau) imaging with sparse apertures. Examples of these mission concepts include the Stellar Imager (SI), the Space Infrared Interferometric Telescope (SPIRIT), the Submillimeter Probe of the Evolution of Cosmic Structure (SPECS), and the Fourier-Kelvin Stellar Interferometer (FKSI). We have been developing computer-based simulators for these missions. These simulators are aimed at providing a quantitative evaluation of the imaging capabilities of the mission by modelling the performance on different realistic targets in terms of sensitivity, angular resolution, and dynamic range. Both Fizeau and Michelson modes of operation can be considered. Our work is based on adapting a computer simulator called imSIM, which was initially written for the Space Interferometer Mission in order to simulate the imaging mode of new missions such as those listed. In a recent GSFC-funded study we have successfully written a preliminary version of a simulator SISIM for the Stellar Imager and carried out some preliminary studies with it. In a separately funded study we have also been applying these methods to SPECS/SPIRIT.

  2. Aerospace Technology Innovation. Volume 10

    NASA Technical Reports Server (NTRS)

    Turner, Janelle (Editor); Cousins, Liz (Editor); Bennett, Evonne (Editor); Vendette, Joel (Editor); West, Kenyon (Editor)

    2002-01-01

    Whether finding new applications for existing NASA technologies or developing unique marketing strategies to demonstrate them, NASA's offices are committed to identifying unique partnering opportunities. Through their efforts NASA leverages resources through joint research and development, and gains new insight into the core areas relevant to all NASA field centers. One of the most satisfying aspects of my job comes when I learn of a mission-driven technology that can be spun-off to touch the lives of everyday people. NASA's New Partnerships in Medical Diagnostic Imaging is one such initiative. Not only does it promise to provide greater dividends for the country's investment in aerospace research, but also to enhance the American quality of life. This issue of Innovation highlights the new NASA-sponsored initiative in medical imaging. Early in 2001, NASA announced the launch of the New Partnerships in Medical Diagnostic Imaging initiative to promote the partnership and commercialization of NASA technologies in the medical imaging industry. NASA and the medical imaging industry share a number of crosscutting technologies in areas such as high-performance detectors and image-processing tools. Many of the opportunities for joint development and technology transfer to the medical imaging market also hold the promise for future spin back to NASA.

  3. Laser initiated spark development in an air gap.

    PubMed

    Lindner, F W; Rudolph, W; Brumme, G; Fischer, H

    1975-09-01

    Spark development is studied by 20-nsec image converter photography. A diffuse and transparent prechannel bridges the gap from the top of the metal vapor jet, which has counterelectrode potential. The prechannel cuts off the development of the cone shaped jet with increasing gap voltage. The final breakdown is initiated by a z-axis, laser induced filament, which expands into the prechannel volume within less, similar10 nsec. This interval represents the final high current thermalization phase of the breakdown. Thermal expansion of the initial spark channel (Braginskii) follows.

  4. Cartographic quality of ERTS-1 images

    NASA Technical Reports Server (NTRS)

    Welch, R. I.

    1973-01-01

    Analyses of simulated and operational ERTS images have provided initial estimates of resolution, ground resolution, detectability thresholds and other measures of image quality of interest to earth scientists and cartographers. Based on these values, including an approximate ground resolution of 250 meters for both RBV and MSS systems, the ERTS-1 images appear suited to the production and/or revision of planimetric and photo maps of 1:500,000 scale and smaller for which map accuracy standards are compatible with the imaged detail. Thematic mapping, although less constrained by map accuracy standards, will be influenced by measurement thresholds and errors which have yet to be accurately determined for ERTS images. This study also indicates the desirability of establishing a quantitative relationship between image quality values and map products which will permit both engineers and cartographers/earth scientists to contribute to the design requirements of future satellite imaging systems.

  5. Accelerated gradient based diffuse optical tomographic image reconstruction.

    PubMed

    Biswas, Samir Kumar; Rajan, K; Vasu, R M

    2011-01-01

    Fast reconstruction of interior optical parameter distribution using a new approach called Broyden-based model iterative image reconstruction (BMOBIIR) and adjoint Broyden-based MOBIIR (ABMOBIIR) of a tissue and a tissue mimicking phantom from boundary measurement data in diffuse optical tomography (DOT). DOT is a nonlinear and ill-posed inverse problem. Newton-based MOBIIR algorithm, which is generally used, requires repeated evaluation of the Jacobian which consumes bulk of the computation time for reconstruction. In this study, we propose a Broyden approach-based accelerated scheme for Jacobian computation and it is combined with conjugate gradient scheme (CGS) for fast reconstruction. The method makes explicit use of secant and adjoint information that can be obtained from forward solution of the diffusion equation. This approach reduces the computational time many fold by approximating the system Jacobian successively through low-rank updates. Simulation studies have been carried out with single as well as multiple inhomogeneities. Algorithms are validated using an experimental study carried out on a pork tissue with fat acting as an inhomogeneity. The results obtained through the proposed BMOBIIR and ABMOBIIR approaches are compared with those of Newton-based MOBIIR algorithm. The mean squared error and execution time are used as metrics for comparing the results of reconstruction. We have shown through experimental and simulation studies that Broyden-based MOBIIR and adjoint Broyden-based methods are capable of reconstructing single as well as multiple inhomogeneities in tissue and a tissue-mimicking phantom. Broyden MOBIIR and adjoint Broyden MOBIIR methods are computationally simple and they result in much faster implementations because they avoid direct evaluation of Jacobian. The image reconstructions have been carried out with different initial values using Newton, Broyden, and adjoint Broyden approaches. These algorithms work well when the initial guess is close to the true solution. However, when initial guess is far away from true solution, Newton-based MOBIIR gives better reconstructed images. The proposed methods are found to be stable with noisy measurement data.

  6. Fully Hydrated Yeast Cells Imaged with Electron Microscopy

    PubMed Central

    Peckys, Diana B.; Mazur, Peter; Gould, Kathleen L.; de Jonge, Niels

    2011-01-01

    We demonstrate electron microscopy of fully hydrated eukaryotic cells with nanometer resolution. Living Schizosaccaromyces pombe cells were loaded in a microfluidic chamber and imaged in liquid with scanning transmission electron microscopy (STEM). The native intracellular (ultra)structures of wild-type cells and three different mutants were studied without prior labeling, fixation, or staining. The STEM images revealed various intracellular components that were identified on the basis of their shape, size, location, and mass density. The maximal achieved spatial resolution in this initial study was 32 ± 8 nm, an order of magnitude better than achievable with light microscopy on pristine cells. Light-microscopy images of the same samples were correlated with the corresponding electron-microscopy images. Achieving synergy between the capabilities of light and electron microscopy, we anticipate that liquid STEM will be broadly applied to explore the ultrastructure of live cells. PMID:21575587

  7. Fully hydrated yeast cells imaged with electron microscopy.

    PubMed

    Peckys, Diana B; Mazur, Peter; Gould, Kathleen L; de Jonge, Niels

    2011-05-18

    We demonstrate electron microscopy of fully hydrated eukaryotic cells with nanometer resolution. Living Schizosaccharomyces pombe cells were loaded in a microfluidic chamber and imaged in liquid with scanning transmission electron microscopy (STEM). The native intracellular (ultra)structures of wild-type cells and three different mutants were studied without prior labeling, fixation, or staining. The STEM images revealed various intracellular components that were identified on the basis of their shape, size, location, and mass density. The maximal achieved spatial resolution in this initial study was 32 ± 8 nm, an order of magnitude better than achievable with light microscopy on pristine cells. Light-microscopy images of the same samples were correlated with the corresponding electron-microscopy images. Achieving synergy between the capabilities of light and electron microscopy, we anticipate that liquid STEM will be broadly applied to explore the ultrastructure of live cells. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  8. Phase-contrast x-ray imaging of microstructure and fatigue-crack propagation in single-crystal nickel-base superalloys

    NASA Astrophysics Data System (ADS)

    Husseini, Naji Sami

    Single-crystal nickel-base superalloys are ubiquitous in demanding turbine-blade applications, and they owe their remarkable resilience to their dendritic, hierarchical microstructure and complex composition. During normal operations, they endure rapid low-stress vibrations that may initiate fatigue cracks. This failure mode in the very high-cycle regime is poorly understood, in part due to inadequate testing and diagnostic equipment. Phase-contrast imaging with coherent synchrotron x rays, however, is an emergent technique ideally suited for dynamic processes such as crack initiation and propagation. A specially designed portable ultrasonic-fatigue apparatus, coupled with x-ray radiography, allows real-time, in situ imaging while simulating service conditions. Three contrast mechanisms - absorption, diffraction, and phase contrast - span the immense breadth of microstructural features in superalloys. Absorption contrast is sensitive to composition and crack displacements, and diffraction contrast illuminates dislocation aggregates and crystallographic misorientations. Phase contrast enhances electron-density gradients and is particularly useful for fatigue-crack studies, sensitive to internal crack tips and openings less than one micrometer. Superalloy samples were imaged without external stresses to study microstructure and mosaicity. Maps of rhenium and tungsten concentrations revealed strong segregation to the center of dendrites, as manifested by absorption contrast. Though nominally single crystals, dendrites were misoriented from the bulk by a few degrees, as revealed by diffraction contrast. For dynamic studies of cyclic fatigue, superalloys were mounted in the portable ultrasonic-fatigue apparatus, subjected to a mean tensile stress of ˜50-150 MPa, and cycled in tension to initiate and propagate fatigue cracks. Radiographs were recorded every thousand cycles over the multimillion-cycle lifetime to measure micron-scale crack growth. Crack openings were very small, as determined by absorption and phase contrast, and suggested multiple fracture modes for propagation along {111} planes at room temperature, which was verified by finite element analysis. With increasing temperature, cracks became Mode I (perpendicular to the loading axis) in character and more sensitive to the microstructure. Advancing plastic zones ahead of crack tips altered the crystallographic quality, from which diffraction contrast anticipated initiation and propagation. These studies demonstrate the extreme sensitivity of x-ray radiography for detailed studies of superalloys and crack growth processes.

  9. The presence of nonthoracic distracting injuries does not affect the initial clinical examination of the cervical spine in evaluable blunt trauma patients: a prospective observational study.

    PubMed

    Konstantinidis, Agathoklis; Plurad, David; Barmparas, Galinos; Inaba, Kenji; Lam, Lydia; Bukur, Marko; Branco, Bernardino C; Demetriades, Demetrios

    2011-09-01

    A distracting injury mandates cervical spine (c-spine) imaging in the evaluable blunt trauma patient who demonstrates no pain or tenderness over the c-spine. The purpose of this study was to examine which distracting injuries can negatively affect the sensitivity of the standard clinical examination of the c-spine. This is a prospective observational study conducted at a Level I Trauma Center from January 1, 2008, to December 31, 2009. After institutional review board approval, all evaluable (Glasgow Coma Scale score ≥13) blunt trauma patients older than 16 years sustaining a c-spine injury were enrolled. A distracting injury was defined as any immediately evident bony or soft tissue injury or a complaint of non-c-spine pain whether or not an actual injury was subsequently diagnosed. Information regarding the initial clinical examination and the presence of a distracting injury was collected from the senior resident or attending trauma surgeon involved in the initial management. During the study period, 101 evaluable patients sustained a c-spine injury. Distracting injuries were present in 88 patients (87.1%). The most common was rib fracture (21.6%), followed by lower extremity fracture (20.5%) and upper extremity fracture (12.5%). Only four (4.0%) patients had no pain or tenderness on the initial examination of the c-spine. All four patients had bruising and tenderness to the upper anterior chest. None of these four patients developed neurologic sequelae or required a surgical stabilization or immobilization. C-spine imaging may not be required in the evaluable blunt trauma patient despite distracting injuries in any body regions that do not involve the upper chest. Further definition of distracting injuries is mandated to avoid unnecessary utilization of resources and to reduce the imaging burden associated with the evaluation of the c-spine.

  10. Contrast-enhanced [18F] fluorodeoxyglucose-positron emission tomography-computed tomography as an initial imaging modality in patients presenting with metastatic malignancy of undefined primary origin

    PubMed Central

    Jain, Avani; Srivastava, Madhur Kumar; Pawaskar, Alok Suresh; Shelley, Simon; Elangovan, Indirani; Jain, Hasmukh; Pandey, Somnath; Kalal, Shilpa; Amalachandran, Jaykanth

    2015-01-01

    Background: To evaluate the advantages of contrast enhanced F-18-fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-contrast enhanced CT [CECT]) when used as an initial imaging modality in patients presenting with metastatic malignancy of undefined primary origin (MUO). Materials and Methods: A total of 243 patients with fine needle aspiration cytology/biopsy proven MUO were included in this prospective study. Patients who were thoroughly evaluated for primary or primary tumor was detected by any other investigation were excluded from the analysis. Totally, 163 patients with pathological diagnosis of malignancy but no apparent sites of the primary tumor were finally selected for analysis. The site of probable primary malignancy suggested by PET-CECT was confirmed by biopsy/follow-up. Results: PET-CECT suggested probable site of primary in 128/163 (78.52%) patients. In 30/35 remaining patients, primary tumor was not detected even after extensive work-up. In 5 patients, where PET-CECT was negative, primary was found on further extensive investigations or follow-up. The sensitivity, specificity, positive predictive value and negative predictive value of the study were 95.76%, 66.67%, 88.28% and 85.71% respectively. Conclusions: F-18 FDG PET-CECT aptly serves the purpose of initial imaging modality owing to high sensitivity, negative and positive predictive value. PET-CECT not only surveys the whole body for the primary malignancy but also stages the disease accurately. Use of contrast improves the diagnostic utility of modality as well as help in staging of the primary tumor. Although benefits of using PET-CECT as initial diagnostic modality are obvious from this study, there is a need for a larger study comparing conventional methods for diagnosing primary in patients with MUO versus PET-CECT. PMID:26170563

  11. Representation of scientific methodology in secondary science textbooks

    NASA Astrophysics Data System (ADS)

    Binns, Ian C.

    The purpose of this investigation was to assess the representation of scientific methodology in secondary science textbooks. More specifically, this study looked at how textbooks introduced scientific methodology and to what degree the examples from the rest of the textbook, the investigations, and the images were consistent with the text's description of scientific methodology, if at all. The sample included eight secondary science textbooks from two publishers, McGraw-Hill/Glencoe and Harcourt/Holt, Rinehart & Winston. Data consisted of all student text and teacher text that referred to scientific methodology. Second, all investigations in the textbooks were analyzed. Finally, any images that depicted scientists working were also collected and analyzed. The text analysis and activity analysis used the ethnographic content analysis approach developed by Altheide (1996). The rubrics used for the text analysis and activity analysis were initially guided by the Benchmarks (AAAS, 1993), the NSES (NRC, 1996), and the nature of science literature. Preliminary analyses helped to refine each of the rubrics and grounded them in the data. Image analysis used stereotypes identified in the DAST literature. Findings indicated that all eight textbooks presented mixed views of scientific methodology in their initial descriptions. Five textbooks placed more emphasis on the traditional view and three placed more emphasis on the broad view. Results also revealed that the initial descriptions, examples, investigations, and images all emphasized the broad view for Glencoe Biology and the traditional view for Chemistry: Matter and Change. The initial descriptions, examples, investigations, and images in the other six textbooks were not consistent. Overall, the textbook with the most appropriate depiction of scientific methodology was Glencoe Biology and the textbook with the least appropriate depiction of scientific methodology was Physics: Principles and Problems. These findings suggest that compared to earlier investigations, textbooks have begun to improve in how they represent scientific methodology. However, there is still much room for improvement. Future research needs to consider how textbooks impact teachers' and students' understandings of scientific methodology.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Legge, K; O’Connor, D J; Nguyen, D

    Purpose: To determine prostate motion during SBRT boost treatments with a Rectafix rectal sparing device in place using kV imaging during treatment. Methods: Patients each had three gold fiducial markers inserted into the prostate and received two VMAT boost fractions of 9.5–10 Gy under the PROMETHEUS clinical trial protocol with a Rectafix rectal retractor in place. Two-dimensional kilovoltage images of fiducial markers were acquired continuously during delivery. Three patients were treated on a Varian Clinac iX linear accelerator (6X, 600 MU/min), where kV images were acquired at 5 Hz during treatment. Seven patients were treated on a Varian Truebeam linearmore » accelerator (10XFFF, 2400 MU/min) where kV images were acquired every 3 seconds. Images were processed off-line using the Kilovoltage Intrafraction Monitoring (KIM) software after treatment. KIM determines prostate position in three dimensions from 2D kV projections using a probability density model and a pre-treatment kV arc. The 3D displacement of the prostate was quantified as a function of time throughout each fraction. Results: From all fractions analyzed, it was found that the prostate had moved less than 1 mm in any direction from its initial position 84.6% of the time. The prostate was between 1 and 2 mm from its initial position 14.2% of the time, between 2 and 3 mm of its initial position 0.8% of the time and was greater than 3 mm from its initial position only 0.4% of the time. Conclusion: The amount of prostate motion observed during prostate SBRT boost treatments with a Rectafix device in place was minimal and lower than that observed in non-Rectafix studies. The Rectafix device reduces rectal dose as well as immobilizing the prostate. Kimberley Legge is the recipient of an Australian Postgraduate Award.« less

  13. The Relationship Between Microscopic Grain Surface Structure and the Dynamic Capillary-Driven Advance of Water Films over Individual Dry Natural Sand Grains

    NASA Astrophysics Data System (ADS)

    Kibbey, T. C. G.; Adegbule, A.; Yan, S.

    2017-12-01

    The movement of nonvolatile solutes in unsaturated porous media at low water contents depends on transport in surface-associated water films. The focus of the work described here was on studying solute movement in water films advancing by capillary forces over initially-dry grain surfaces, to understand how microscopic surface roughness features influence the initial velocity of water film advance. For this work, water containing a non-adsorbing conservative tracer was used to track the movement of advancing water films. A stainless steel capillary tube connected to an external reservoir a fixed distance below the grain surface was used to transmit solution to the grain surface under negative pressure (positive capillary pressure), consistent with conditions that might be expected in the unsaturated zone. The small internal diameter of the capillary prevents solution from draining out of the capillary back into the reservoir. When the capillary is contacted with a grain surface, capillary forces that result from contact between the fluid and the rough grain surface cause water films to wick across the grain surface. Multiple experiments were conducted on the same grain, rotating the grain and varying the capillary contact point around the circumference of the grain. Imaging was conducted at fixed intervals using an automated Extended Depth of Field (EDF) imaging system, and images were analyzed to determine initial velocity. Grain surfaces were then characterized through scanning electron microscope (SEM) imaging, using a hybrid stereoscopic reconstruction method designed to extract maximum detail in creating elevation maps of geologic surfaces from tilted pairs of SEM images. The resulting elevation maps were used to relate surface roughness profiles around the grain with initial velocities. Results suggest that velocity varies significant with contact point around an individual grain, and correlates quantitatively with the local grain surface structure. Preliminary simulation results will also be discussed.

  14. Multispectral and geomorphic studies of processed Voyager 2 images of Europa

    NASA Technical Reports Server (NTRS)

    Meier, T. A.

    1984-01-01

    High resolution images of Europa taken by the Voyager 2 spacecraft were used to study a portion of Europa's dark lineations and the major white line feature Agenor Linea. Initial image processing of images 1195J2-001 (violet filter), 1198J2-001 (blue filter), 1201J2-001 (orange filter), and 1204J2-001 (ultraviolet filter) was performed at the U.S.G.S. Branch of Astrogeology in Flagstaff, Arizona. Processing was completed through the stages of image registration and color ratio image construction. Pixel printouts were used in a new technique of linear feature profiling to compensate for image misregistration through the mapping of features on the printouts. In all, 193 dark lineation segments were mapped and profiled. The more accurate multispectral data derived by this method was plotted using a new application of the ternary diagram, with orange, blue, and violet relative spectral reflectances serving as end members. Statistical techniques were then applied to the ternary diagram plots. The image products generated at LPI were used mainly to cross-check and verify the results of the ternary diagram analysis.

  15. Automated detection of analyzable metaphase chromosome cells depicted on scanned digital microscopic images

    NASA Astrophysics Data System (ADS)

    Qiu, Yuchen; Wang, Xingwei; Chen, Xiaodong; Li, Yuhua; Liu, Hong; Li, Shibo; Zheng, Bin

    2010-02-01

    Visually searching for analyzable metaphase chromosome cells under microscopes is quite time-consuming and difficult. To improve detection efficiency, consistency, and diagnostic accuracy, an automated microscopic image scanning system was developed and tested to directly acquire digital images with sufficient spatial resolution for clinical diagnosis. A computer-aided detection (CAD) scheme was also developed and integrated into the image scanning system to search for and detect the regions of interest (ROI) that contain analyzable metaphase chromosome cells in the large volume of scanned images acquired from one specimen. Thus, the cytogeneticists only need to observe and interpret the limited number of ROIs. In this study, the high-resolution microscopic image scanning and CAD performance was investigated and evaluated using nine sets of images scanned from either bone marrow (three) or blood (six) specimens for diagnosis of leukemia. The automated CAD-selection results were compared with the visual selection. In the experiment, the cytogeneticists first visually searched for the analyzable metaphase chromosome cells from specimens under microscopes. The specimens were also automated scanned and followed by applying the CAD scheme to detect and save ROIs containing analyzable cells while deleting the others. The automated selected ROIs were then examined by a panel of three cytogeneticists. From the scanned images, CAD selected more analyzable cells than initially visual examinations of the cytogeneticists in both blood and bone marrow specimens. In general, CAD had higher performance in analyzing blood specimens. Even in three bone marrow specimens, CAD selected 50, 22, 9 ROIs, respectively. Except matching with the initially visual selection of 9, 7, and 5 analyzable cells in these three specimens, the cytogeneticists also selected 41, 15 and 4 new analyzable cells, which were missed in initially visual searching. This experiment showed the feasibility of applying this CAD-guided high-resolution microscopic image scanning system to prescreen and select ROIs that may contain analyzable metaphase chromosome cells. The success and the further improvement of this automated scanning system may have great impact on the future clinical practice in genetic laboratories to detect and diagnose diseases.

  16. Hybrid active contour model for inhomogeneous image segmentation with background estimation

    NASA Astrophysics Data System (ADS)

    Sun, Kaiqiong; Li, Yaqin; Zeng, Shan; Wang, Jun

    2018-03-01

    This paper proposes a hybrid active contour model for inhomogeneous image segmentation. The data term of the energy function in the active contour consists of a global region fitting term in a difference image and a local region fitting term in the original image. The difference image is obtained by subtracting the background from the original image. The background image is dynamically estimated from a linear filtered result of the original image on the basis of the varying curve locations during the active contour evolution process. As in existing local models, fitting the image to local region information makes the proposed model robust against an inhomogeneous background and maintains the accuracy of the segmentation result. Furthermore, fitting the difference image to the global region information makes the proposed model robust against the initial contour location, unlike existing local models. Experimental results show that the proposed model can obtain improved segmentation results compared with related methods in terms of both segmentation accuracy and initial contour sensitivity.

  17. Design and development of C-arm based cone-beam CT for image-guided interventions: initial results

    NASA Astrophysics Data System (ADS)

    Chen, Guang-Hong; Zambelli, Joseph; Nett, Brian E.; Supanich, Mark; Riddell, Cyril; Belanger, Barry; Mistretta, Charles A.

    2006-03-01

    X-ray cone-beam computed tomography (CBCT) is of importance in image-guided intervention (IGI) and image-guided radiation therapy (IGRT). In this paper, we present a cone-beam CT data acquisition system using a GE INNOVA 4100 (GE Healthcare Technologies, Waukesha, Wisconsin) clinical system. This new cone-beam data acquisition mode was developed for research purposes without interfering with any clinical function of the system. It provides us a basic imaging pipeline for more advanced cone-beam data acquisition methods. It also provides us a platform to study and overcome the limiting factors such as cone-beam artifacts and limiting low contrast resolution in current C-arm based cone-beam CT systems. A geometrical calibration method was developed to experimentally determine parameters of the scanning geometry to correct the image reconstruction for geometric non-idealities. Extensive phantom studies and some small animal studies have been conducted to evaluate the performance of our cone-beam CT data acquisition system.

  18. Image registration based on subpixel localization and Cauchy-Schwarz divergence

    NASA Astrophysics Data System (ADS)

    Ge, Yongxin; Yang, Dan; Zhang, Xiaohong; Lu, Jiwen

    2010-07-01

    We define a new matching metric-corner Cauchy-Schwarz divergence (CCSD) and present a new approach based on the proposed CCSD and subpixel localization for image registration. First, we detect the corners in an image by a multiscale Harris operator and take them as initial interest points. And then, a subpixel localization technique is applied to determine the locations of the corners and eliminate the false and unstable corners. After that, CCSD is defined to obtain the initial matching corners. Finally, we use random sample consensus to robustly estimate the parameters based on the initial matching. The experimental results demonstrate that the proposed algorithm has a good performance in terms of both accuracy and efficiency.

  19. Serial magnetic resonance imaging findings in subarachnoid hemorrhage due to an initially angiographically occult type II spinal aneurysm: Case report.

    PubMed

    Kogan, Michael; Morr, Simon; Siddiqui, Adnan H

    2017-04-28

    Spinal aneurysms are rare causes of spontaneous subarachnoid hemorrhage. We present an unusual, initially occult, case of an upper thoracic intradural extramedullary isolated aneurysm arising from the T2 intercostal-radicular circulation that was initially angiographically occult but was discovered due to unique, albeit nonspecific, magnetic resonance imaging findings of spinal cord T2 hyperintensity and contrast enhancement that were noted to progress with a clinical picture of ictal rehemorrhage. Repeat spinal angiography revealed a spinal aneurysm that was treated surgically. In cases of sufficient clinical suspicion and nonspecific imaging findings, continued vigilance is advised in seeking an underlying pathoanatomic etiology.

  20. The Cortex Transform as an image preprocessor for sparse distributed memory: An initial study

    NASA Technical Reports Server (NTRS)

    Olshausen, Bruno; Watson, Andrew

    1990-01-01

    An experiment is described which was designed to evaluate the use of the Cortex Transform as an image processor for Sparse Distributed Memory (SDM). In the experiment, a set of images were injected with Gaussian noise, preprocessed with the Cortex Transform, and then encoded into bit patterns. The various spatial frequency bands of the Cortex Transform were encoded separately so that they could be evaluated based on their ability to properly cluster patterns belonging to the same class. The results of this study indicate that by simply encoding the low pass band of the Cortex Transform, a very suitable input representation for the SDM can be achieved.

  1. Ultrasound fusion image error correction using subject-specific liver motion model and automatic image registration.

    PubMed

    Yang, Minglei; Ding, Hui; Zhu, Lei; Wang, Guangzhi

    2016-12-01

    Ultrasound fusion imaging is an emerging tool and benefits a variety of clinical applications, such as image-guided diagnosis and treatment of hepatocellular carcinoma and unresectable liver metastases. However, respiratory liver motion-induced misalignment of multimodal images (i.e., fusion error) compromises the effectiveness and practicability of this method. The purpose of this paper is to develop a subject-specific liver motion model and automatic registration-based method to correct the fusion error. An online-built subject-specific motion model and automatic image registration method for 2D ultrasound-3D magnetic resonance (MR) images were combined to compensate for the respiratory liver motion. The key steps included: 1) Build a subject-specific liver motion model for current subject online and perform the initial registration of pre-acquired 3D MR and intra-operative ultrasound images; 2) During fusion imaging, compensate for liver motion first using the motion model, and then using an automatic registration method to further correct the respiratory fusion error. Evaluation experiments were conducted on liver phantom and five subjects. In the phantom study, the fusion error (superior-inferior axis) was reduced from 13.90±2.38mm to 4.26±0.78mm by using the motion model only. The fusion error further decreased to 0.63±0.53mm by using the registration method. The registration method also decreased the rotation error from 7.06±0.21° to 1.18±0.66°. In the clinical study, the fusion error was reduced from 12.90±9.58mm to 6.12±2.90mm by using the motion model alone. Moreover, the fusion error decreased to 1.96±0.33mm by using the registration method. The proposed method can effectively correct the respiration-induced fusion error to improve the fusion image quality. This method can also reduce the error correction dependency on the initial registration of ultrasound and MR images. Overall, the proposed method can improve the clinical practicability of ultrasound fusion imaging. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. In Vivo Imaging and Monitoring of Transplanted Stem Cells: Clinical Applications

    PubMed Central

    Rodriguez-Porcel, Martin

    2010-01-01

    Regenerative medicine using stem cells has appeared as a potential therapeutic alternative for coronary artery disease, and stem cell clinical studies are currently on their way. However, initial results of these studies have provided mixed information, in part because of the inability to correlate organ functional information with the presence/absence of transplanted stem cells. Recent advances in molecular biology and imaging have allowed the successful noninvasive monitoring of transplanted stem cells in the living subject. In this article, different imaging strategies (direct labeling, indirect labeling with reporter genes) to study the viability and biology of stem cells are discussed. In addition, the limitations of each approach and imaging modality (eg, single photon emission computed tomography, positron emission tomography, and MRI) and their requirements for clinical use are addressed. Use of these strategies will be critical as the different regenerative therapies are being tested for clinical use. PMID:20425184

  3. Real-time landmark-based unrestrained animal tracking system for motion-corrected PET/SPECT imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J.S. Goddard; S.S. Gleason; M.J. Paulus

    2003-08-01

    Oak Ridge National Laboratory (ORNL) and Jefferson Lab and are collaborating to develop a new high-resolution single photon emission tomography (SPECT) instrument to image unrestrained laboratory animals. This technology development will allow functional imaging studies to be performed on the animals without the use of anesthetic agents. This technology development could have eventual clinical applications for performing functional imaging studies on patients that cannot remain still (Parkinson's patients, Alzheimer's patients, small children, etc.) during a PET or SPECT scan. A key component of this new device is the position tracking apparatus. The tracking apparatus is an integral part of themore » gantry and designed to measure the spatial position of the animal at a rate of 10-15 frames per second with sub-millimeter accuracy. Initial work focuses on brain studies where anesthetic agents or physical restraint can significantly impact physiologic processes.« less

  4. Advising the Student-Athlete.

    ERIC Educational Resources Information Center

    Gurney, Gerald S.; Johnson, Sally P.

    1986-01-01

    Some recent institutional studies describing the academic preparation and subsequent performance of student-athletes are reviewed, and their implication for academic advising is discussed. "Dumb Jock" image, initial academic advisor contact, fifth-year grant programs, are among the issues described. (MLW)

  5. NASA to Survey Earth's Resources

    NASA Technical Reports Server (NTRS)

    Mittauer, R. T.

    1971-01-01

    A wide variety of the natural resources of earth and man's management of them will be studied by an initial group of foreign and domestic scientists tentatively chosen by the National Aeronautics and Space Administration to analyze data to be gathered by two earth-orbiting spacecraft. The spacecraft are the first Earth Resources Technology Satellite (ERTS-A) and the manned Skylab which will carry an Earth Resources Experiment Package (EREP). In the United States, the initial experiments will study the feasibility of remote sensing from a satellite in gathering information on ecological problems. The objective of both ERTS and EREP aboard Skylab is to obtain multispectral images of the surface of the earth with high resolution remote sensors and to process and distribute the images to scientific users in a wide variety of disciplines. The ERTS-A, EREP, and Skylab systems are described and their operation is discussed.

  6. Initial application of stereoscopic particle image velocimetry to transport and boundary phenomena in dusty plasmas

    NASA Astrophysics Data System (ADS)

    Thomas, Edward; Williams, Jeremiah; Silver, Jennifer

    2004-11-01

    Over the past five years, the Auburn Plasma Sciences Laboratory (PSL) has applied two-dimensional particle image velocimetry (2D-PIV) techniques [E. Thomas, Phys. Plasmas, 6, 2672 (1999)] to make measurements of particle transport in dusty plasmas. Although important information was obtained from these earlier studies, the complex behavior of the charged microparticles clearly indicated that three-dimensional velocity information is needed. The PSL has recently acquired and installed a stereoscopic PIV (stereo-PIV) diagnostic tool for dusty plasma investigations [E. Thomas. et al, Phys. Plasmas, L37 (2004)]. It employs a synchronized dual-laser, dual-camera system for measuring particle transport in three dimensions. Results will be presented on the initial application of stereo-PIV to dusty plasma studies. Additional results will be presented on the use of stereo-PIV for measuring the controlled interaction of two dust clouds.

  7. A modeling analysis program for the JPL table mountain Io sodium cloud

    NASA Technical Reports Server (NTRS)

    Smyth, W. H.; Goldberg, B. A.

    1985-01-01

    Progress and achievements in the first year are discussed in three main areas: (1) review and assessment of the massive JPL Table Mountain Io sodium cloud data set, (2) formulation and execution of a plan to perform further processing of this data set, and (3) initiation of modeling activities. The complete 1976-79 and 1981 data sets are reviewed. Particular emphasis is placed on the superior 1981 Region B/C images which provide a rich base of information for studying the structure and escape of gases from Io as well as possible east-west and magnetic longitudinal asymmetries in the plasma torus. A data processing plan is developed and is undertaken by the Multimission Image Processing Laboratory of JPL for the purpose of providing a more refined and complete data set for our modeling studies in the second year. Modeling priorities are formulated and initial progress in achieving these goals is reported.

  8. Development of tyrosinase-based reporter genes for preclinical photoacoustic imaging of mesenchymal stem cells

    NASA Astrophysics Data System (ADS)

    Märk, Julia; Ruschke, Karen; Dortay, Hakan; Schreiber, Isabelle; Sass, Andrea; Qazi, Taimoor; Pumberger, Matthias; Laufer, Jan

    2014-03-01

    The capability to image stem cells in vivo in small animal models over extended periods of time is important to furthering our understanding of the processes involved in tissue regeneration. Photoacoustic imaging is suited to this application as it can provide high resolution (tens of microns) absorption-based images of superficial tissues (cm depths). However, stem cells are rare, highly migratory, and can divide into more specialised cells. Genetic labelling strategies are therefore advantageous for their visualisation. In this study, methods for the transfection and viral transduction of mesenchymal stem cells with reporter genes for the co-expression of tyrosinase and a fluorescent protein (mCherry). Initial photoacoustic imaging experiments of tyrosinase expressing cells in small animal models of tissue regeneration were also conducted. Lentiviral transduction methods were shown to result in stable expression of tyrosinase and mCherry in mesenchymal stem cells. The results suggest that photoacoustic imaging using reporter genes is suitable for the study of stem cell driven tissue regeneration in small animals.

  9. RADIOLOGY EDUCATION: A PILOT STUDY TO ASSESS KNOWLEDGE OF MEDICAL STUDENTS REGARDING IMAGING IN TRAUMA.

    PubMed

    Siddiqui, Saad; Saeed, Muhammad Anwar; Shah, Noreen; Nadeem, Naila

    2015-01-01

    Trauma remains one of the most frequent presentations in emergency departments. Imaging has established role in setting of acute trauma with ability to identify potentially fatal conditions. Adequate knowledge of health professionals regarding trauma imaging is vital for improved healthcare. In this work we try to assess knowledge of medical students regarding imaging in trauma as well as identify most effective way of imparting radiology education. This cross-sectional pilot study was conducted at Aga Khan University Medical College & Khyber Girls Medical College, to assess knowledge of medical students regarding imaging protocols practiced in initial management of trauma patients. Only 40 & 20% respectively were able to identify radiographs included in trauma series. Very few had knowledge of correct indication for Focused abdominal sonography in trauma. Clinical radiology rotation was reported as best way of learning radiology. Change in curricula & restructuring of clinical radiology rotation structure is needed to improve knowledge regarding Trauma imaging.

  10. Ultrasound tomography imaging with waveform sound speed: parenchymal changes in women undergoing tamoxifen therapy

    NASA Astrophysics Data System (ADS)

    Sak, Mark; Duric, Neb; Littrup, Peter; Sherman, Mark; Gierach, Gretchen

    2017-03-01

    Ultrasound tomography (UST) is an emerging modality that can offer quantitative measurements of breast density. Recent breakthroughs in UST image reconstruction involve the use of a waveform reconstruction as opposed to a raybased reconstruction. The sound speed (SS) images that are created using the waveform reconstruction have a much higher image quality. These waveform images offer improved resolution and contrasts between regions of dense and fatty tissues. As part of a study that was designed to assess breast density changes using UST sound speed imaging among women undergoing tamoxifen therapy, UST waveform sound speed images were then reconstructed for a subset of participants. These initial results show that changes to the parenchymal tissue can more clearly be visualized when using the waveform sound speed images. Additional quantitative testing of the waveform images was also started to test the hypothesis that waveform sound speed images are a more robust measure of breast density than ray-based reconstructions. Further analysis is still needed to better understand how tamoxifen affects breast tissue.

  11. The effect of initial pressure on growth of FeNPs in amorphous carbon films

    NASA Astrophysics Data System (ADS)

    Mashayekhi, Fatemeh; Shafiekhani, Azizollah; Sebt, S. Ali; Darabi, Elham

    2018-04-01

    Iron nanoparticles in amorphous hydrogenated carbon films (FeNPs@a-C:H) were prepared with RF-sputtering and RFPECVD methods by acetylene gas and Fe target. In this paper, deposition and sputtering process were carried out under influence of different initial pressure gas. The morphology and roughness of surface of samples were studied by AFM technique and also TEM images show the exact size of FeNPs and encapsulated FeNPs@a-C:H. The localized surface plasmon resonance peak (LSPR) of FeNPs was studied using UV-vis absorption spectrum. The results show that the intensity and position of LSPR peak are increased by increasing initial pressure. Also, direct energy gap of samples obtained by Tauc law is decreased with respect to increasing initial pressure.

  12. Automated Bulk Uploading of Images and Metadata to Flickr

    ERIC Educational Resources Information Center

    Michel, Jason Paul; Tzoc, Elias

    2010-01-01

    The Digital Initiatives department at Miami University, like most digital initiatives and special collections departments, has a large number of rich digital image collections, stored primarily in a third-party database. Typically, these databases are not findable to the average Web user. From a desire to expose these collections to the wider Web…

  13. The NASA Planetary Data System's Cartography and Imaging Sciences Node and the Planetary Spatial Data Infrastructure (PSDI) Initiative

    NASA Astrophysics Data System (ADS)

    Gaddis, L. R.; Laura, J.; Hare, T.; Hagerty, J.

    2017-06-01

    Here we address the role of the PSDI initiative in the context of work to archive and deliver planetary data by NASA’s Planetary Data System, and in particular by the PDS Cartography and Imaging Sciences Discipline Node (aka “Imaging” or IMG).

  14. Stroke Severity Affects Timing: Time From Stroke Code Activation to Initial Imaging is Longer in Patients With Milder Strokes.

    PubMed

    Kwei, Kimberly T; Liang, John; Wilson, Natalie; Tuhrim, Stanley; Dhamoon, Mandip

    2018-05-01

    Optimizing the time it takes to get a potential stroke patient to imaging is essential in a rapid stroke response. At our hospital, door-to-imaging time is comprised of 2 time periods: the time before a stroke is recognized, followed by the period after the stroke code is called during which the stroke team assesses and brings the patient to the computed tomography scanner. To control for delays due to triage, we isolated the time period after a potential stroke has been recognized, as few studies have examined the biases of stroke code responders. This "code-to-imaging time" (CIT) encompassed the time from stroke code activation to initial imaging, and we hypothesized that perception of stroke severity would affect how quickly stroke code responders act. In consecutively admitted ischemic stroke patients at The Mount Sinai Hospital emergency department, we tested associations between National Institutes of Health Stroke Scale scores (NIHSS), continuously and at different cutoffs, and CIT using spline regression, t tests for univariate analysis, and multivariable linear regression adjusting for age, sex, and race/ethnicity. In our study population, mean CIT was 26 minutes, and mean presentation NIHSS was 8. In univariate and multivariate analyses comparing CIT between mild and severe strokes, stroke scale scores <4 were associated with longer response times. Milder strokes are associated with a longer CIT with a threshold effect at a NIHSS of 4.

  15. Self-image and self-esteem in African-American preteen girls: implications for mental health.

    PubMed

    Doswell, W M; Millor, G K; Thompson, H; Braxter, B

    1998-01-01

    Current research suggests that pubertal development is occurring earlier in African-American preteen girls in response to familial contextual factors, which may make them vulnerable to low self-image and self-esteem dissatisfaction. This lowering in self-image and self-esteem may contribute to the early initiation of sexual behaviors, putting these girls at risk for pregnancy and sexually transmitted diseases. These potential risks place these girls in need of prepubertal health promotion, yet preadolescents are not frequently a focus of nursing care delivery except when summer camp and back-to-school physicals are performed. This article presents an in-depth overview of selected literature on self-esteem, discusses findings on self-image and self-esteem from a pilot study on pubertal influences on accelerated sexual behavior, and proposes health promotion strategies for pre- and peripubertal girls to promote positive mental health outcomes. More focused attention is needed on health promotion targeting the developmental transition health needs of prepubertal girls. Targeted health promotion activities may foster healthier pre- and peripubertal girls' perceptions of the meaning of their pubertal physical changes and stronger self-image and self-esteem. The goal of these health promotion activities should be to foster continuity of positive self-image and self-esteem among preteen girls, which is essential to prevent initiation of premature-for-age risk of problem behavior, such as early coitus.

  16. Noninvasive identification of peripheral vessels of oral and maxillofacial regions by using electrocardiography-triggered three-dimensional fast asymmetric spin-echo sequences.

    PubMed

    Tanaka, Tatsurou; Oda, Masafumi; Kito, Shinji; Wakasugi-Sato, Nao; Matsumoto-Takeda, Shinobu; Otsuka, Kozue; Yoshioka, Izumi; Habu, Manabu; Kokuryo, Shinya; Kodama, Masaaki; Nogami, Shinnosuke; Miyamoto, Ikuya; Yamamoto, Noriaki; Ishikawa, Ayataka; Matsuo, Kou; Shiiba, Shunji; Seta, Yuji; Yamashita, Yoshihiro; Takahashi, Tetsu; Tominaga, Kazuhiro; Morimoto, Yasuhiro

    2011-10-01

    The aim of this study was to evaluate the 3-dimensional images of thinner main peripheral vessels in oral and maxillofacial regions made without contrast medium by using a new technique, fresh blood imaging (FBI). A second objective was to discern arteries from veins by using the combination of FBI with the subtraction technique. Images from FBI were compared with those from 3-dimensional phase-contrast magnetic resonance angiography (MRA) of blood vessels in 20 healthy subjects. All images were scored for visualization and image quality of the main blood vessels. In addition, appropriate flow-spoiled gradient pulses were applied to differentiate arteries from veins in the peripheral vasculature using a combination of FBI sequences and subtraction between systole- and diastole-triggered images. The scores of MRA using FBI for the visualization of thin blood vessels were significantly better than those using phase contrast, whereas scores for the visualization of main blood vessels were equal. Additionally, we succeeded in our initial attempt to differentiate arteries from veins with a reasonable acquisition time. Our initial experience shows that FBI could be a useful method to identify 3-dimensional vasculature and to differentiate arteries from veins among thinner peripheral vessels in the oral and maxillofacial regions without using contrast medium. Copyright © 2011 Mosby, Inc. All rights reserved.

  17. Peripheral Quantitative CT (pQCT) Using a Dedicated Extremity Cone-Beam CT Scanner

    PubMed Central

    Muhit, A. A.; Arora, S.; Ogawa, M.; Ding, Y.; Zbijewski, W.; Stayman, J. W.; Thawait, G.; Packard, N.; Senn, R.; Yang, D.; Yorkston, J.; Bingham, C.O.; Means, K.; Carrino, J. A.; Siewerdsen, J. H.

    2014-01-01

    Purpose We describe the initial assessment of the peripheral quantitative CT (pQCT) imaging capabilities of a cone-beam CT (CBCT) scanner dedicated to musculoskeletal extremity imaging. The aim is to accurately measure and quantify bone and joint morphology using information automatically acquired with each CBCT scan, thereby reducing the need for a separate pQCT exam. Methods A prototype CBCT scanner providing isotropic, sub-millimeter spatial resolution and soft-tissue contrast resolution comparable or superior to standard multi-detector CT (MDCT) has been developed for extremity imaging, including the capability for weight-bearing exams and multi-mode (radiography, fluoroscopy, and volumetric) imaging. Assessment of pQCT performance included measurement of bone mineral density (BMD), morphometric parameters of subchondral bone architecture, and joint space analysis. Measurements employed phantoms, cadavers, and patients from an ongoing pilot study imaged with the CBCT prototype (at various acquisition, calibration, and reconstruction techniques) in comparison to MDCT (using pQCT protocols for analysis of BMD) and micro-CT (for analysis of subchondral morphometry). Results The CBCT extremity scanner yielded BMD measurement within ±2–3% error in both phantom studies and cadaver extremity specimens. Subchondral bone architecture (bone volume fraction, trabecular thickness, degree of anisotropy, and structure model index) exhibited good correlation with gold standard micro-CT (error ~5%), surpassing the conventional limitations of spatial resolution in clinical MDCT scanners. Joint space analysis demonstrated the potential for sensitive 3D joint space mapping beyond that of qualitative radiographic scores in application to non-weight-bearing versus weight-bearing lower extremities and assessment of phalangeal joint space integrity in the upper extremities. Conclusion The CBCT extremity scanner demonstrated promising initial results in accurate pQCT analysis from images acquired with each CBCT scan. Future studies will include improved x-ray scatter correction and image reconstruction techniques to further improve accuracy and to correlate pQCT metrics with known pathology. PMID:25076823

  18. SU-E-T-217: Intrinsic Respiratory Gating in Small Animal CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Y; Smith, M; Mistry, N

    Purpose: Preclinical animal models of lung cancer can provide a controlled test-bed for testing dose escalation or function-based-treatment-planning studies. However, to extract lung function, i.e. ventilation, one needs to be able to image the lung at different phases of ventilation (in-hale / ex-hale). Most respiratory-gated imaging using micro-CT involves using an external ventilator and surgical intervention limiting the utility in longitudinal studies. A new intrinsic respiratory retrospective gating method was developed and tested in mice. Methods: A fixed region of interest (ROI) that covers the diaphragm was selected on all projection images to estimate the mean intensity (M). The meanmore » intensity depends on the projection angle and diaphragm position. A 3-point moving average (A) of consecutive M values: Mpre, Mcurrent and Mpost, was calculated to be subtracted from Mcurrent. A fixed threshold was used to enable amplitude based sorting into 4 different phases of respiration. Images at full-inhale and end-exhale phases of respiration were reconstructed using the open source OSCaR. Lung volumes estimated at the 2 phases of respiration were validated against literature values. Results: Intrinsic retrospective gating was accomplished without the use of any external breathing waveform. While projection images were acquired at 360 different angles. Only 138 and 104 projections were used to reconstruct images at full-inhale and end-exhale. This often results in non-uniform under-sampled angular projections leading to some minor streaking artifacts. The calculated expiratory, inspiratory and tidal lung volumes correlated well with the values known from the literature. Conclusion: Our initial result demonstrates an intrinsic gating method that is suitable for flat panel cone beam small animal CT systems. Reduction in streaking artifacts can be accomplished by oversampling the data or using iterative reconstruction methods. This initial experience will enable freebreathing small animal micro-CT imaging to fuel longitudinal studies of lung function.« less

  19. Towards a five-minute comprehensive cardiac MR examination using highly accelerated parallel imaging with a 32-element coil array: feasibility and initial comparative evaluation.

    PubMed

    Xu, Jian; Kim, Daniel; Otazo, Ricardo; Srichai, Monvadi B; Lim, Ruth P; Axel, Leon; Mcgorty, Kelly Anne; Niendorf, Thoralf; Sodickson, Daniel K

    2013-07-01

    To evaluate the feasibility and perform initial comparative evaluations of a 5-minute comprehensive whole-heart magnetic resonance imaging (MRI) protocol with four image acquisition types: perfusion (PERF), function (CINE), coronary artery imaging (CAI), and late gadolinium enhancement (LGE). This study protocol was Health Insurance Portability and Accountability Act (HIPAA)-compliant and Institutional Review Board-approved. A 5-minute comprehensive whole-heart MRI examination protocol (Accelerated) using 6-8-fold-accelerated volumetric parallel imaging was incorporated into and compared with a standard 2D clinical routine protocol (Standard). Following informed consent, 20 patients were imaged with both protocols. Datasets were reviewed for image quality using a 5-point Likert scale (0 = non-diagnostic, 4 = excellent) in blinded fashion by two readers. Good image quality with full whole-heart coverage was achieved using the accelerated protocol, particularly for CAI, although significant degradations in quality, as compared with traditional lengthy examinations, were observed for the other image types. Mean total scan time was significantly lower for the Accelerated as compared to Standard protocols (28.99 ± 4.59 min vs. 1.82 ± 0.05 min, P < 0.05). Overall image quality for the Standard vs. Accelerated protocol was 3.67 ± 0.29 vs. 1.5 ± 0.51 (P < 0.005) for PERF, 3.48 ± 0.64 vs. 2.6 ± 0.68 (P < 0.005) for CINE, 2.35 ± 1.01 vs. 2.48 ± 0.68 (P = 0.75) for CAI, and 3.67 ± 0.42 vs. 2.67 ± 0.84 (P < 0.005) for LGE. Diagnostic image quality for Standard vs. Accelerated protocols was 20/20 (100%) vs. 10/20 (50%) for PERF, 20/20 (100%) vs. 18/20 (90%) for CINE, 18/20 (90%) vs. 18/20 (90%) for CAI, and 20/20 (100%) vs. 18/20 (90%) for LGE. This study demonstrates the technical feasibility and promising image quality of 5-minute comprehensive whole-heart cardiac examinations, with simplified scan prescription and high spatial and temporal resolution enabled by highly parallel imaging technology. The study also highlights technical hurdles that remain to be addressed. Although image quality remained diagnostic for most scan types, the reduced image quality of PERF, CINE, and LGE scans in the Accelerated protocol remain a concern. Copyright © 2012 Wiley Periodicals, Inc.

  20. New Zealand among global social media initiative leaders for primary care advocacy.

    PubMed

    Hoedebecke, Kyle; Scott-Jones, Joseph; Pinho-Costa, Luís

    2016-06-01

    The international '#1WordforFamilyMedicine' initiative explores the identity of General Practitioners (GPs) and Family Physicians (FPs) by allowing the international Family Medicine community to collaborate on advocating for the discipline via social media. The New Zealand version attracted 83 responses on social media. Thematic analysis was performed on the responses and a 'word cloud' image was created based on an image identifying the country around the world - that of the silver fern. The '#1WorldforFamilyMedicine' project was promoted by WONCA (World Organisation of Family Doctors) globally to help celebrate World Family Doctor Day on 19 May 2015. To date, over 80 images have been created in 60 different countries on six continents. The images represent GPs' love for their profession and the community they serve. We hope that this initiative will help inspire current and future Family Medicine and Primary Care providers.

  1. Spontaneous Coronary Artery Dissection: A Disease-Specific, Social Networking Community–Initiated Study

    PubMed Central

    Tweet, Marysia S.; Gulati, Rajiv; Aase, Lee A.; Hayes, Sharonne N.

    2011-01-01

    OBJECTIVE: To develop and assess the feasibility of a novel method for identification, recruitment, and retrospective and prospective evaluation of patients with rare conditions. PATIENTS AND METHODS: This pilot study is a novel example of “patient-initiated research.” After being approached by several members of an international disease-specific support group on a social networking site, we used it to identify patients who had been diagnosed as having at least 1 episode of spontaneous coronary artery dissection and recruited them to participate in a clinical investigation of their condition. Medical records were collected and reviewed, the original diagnosis was independently confirmed by review of imaging studies, and health status (both interval and current) was assessed via specially designed questionnaires and validated assessment tools. RESULTS: Recruitment of all 12 participants was complete within 1 week of institutional review board approval (March 18, 2010). Data collection was completed November 18, 2010. All participants completed the study questionnaires and provided the required medical records and coronary angiograms and ancillary imaging data. CONCLUSION: This study involving patients with spontaneous coronary artery dissection demonstrates the feasibility of and is a successful model for developing a “virtual” multicenter disease registry through disease-specific social media networks to better characterize an uncommon condition. This study is a prime example of patient-initiated research that could be used by other health care professionals and institutions. PMID:21878595

  2. Spontaneous coronary artery dissection: a disease-specific, social networking community-initiated study.

    PubMed

    Tweet, Marysia S; Gulati, Rajiv; Aase, Lee A; Hayes, Sharonne N

    2011-09-01

    To develop and assess the feasibility of a novel method for identification, recruitment, and retrospective and prospective evaluation of patients with rare conditions. This pilot study is a novel example of "patient-initiated research." After being approached by several members of an international disease-specific support group on a social networking site, we used it to identify patients who had been diagnosed as having at least 1 episode of spontaneous coronary artery dissection and recruited them to participate in a clinical investigation of their condition. Medical records were collected and reviewed, the original diagnosis was independently confirmed by review of imaging studies, and health status (both interval and current) was assessed via specially designed questionnaires and validated assessment tools. Recruitment of all 12 participants was complete within 1 week of institutional review board approval (March 18, 2010). Data collection was completed November 18, 2010. All participants completed the study questionnaires and provided the required medical records and coronary angiograms and ancillary imaging data. This study involving patients with spontaneous coronary artery dissection demonstrates the feasibility of and is a successful model for developing a "virtual" multicenter disease registry through disease-specific social media networks to better characterize an uncommon condition. This study is a prime example of patient-initiated research that could be used by other health care professionals and institutions.

  3. Nonrigid synthetic aperture radar and optical image coregistration by combining local rigid transformations using a Kohonen network.

    PubMed

    Salehpour, Mehdi; Behrad, Alireza

    2017-10-01

    This study proposes a new algorithm for nonrigid coregistration of synthetic aperture radar (SAR) and optical images. The proposed algorithm employs point features extracted by the binary robust invariant scalable keypoints algorithm and a new method called weighted bidirectional matching for initial correspondence. To refine false matches, we assume that the transformation between SAR and optical images is locally rigid. This property is used to refine false matches by assigning scores to matched pairs and clustering local rigid transformations using a two-layer Kohonen network. Finally, the thin plate spline algorithm and mutual information are used for nonrigid coregistration of SAR and optical images.

  4. Magnetic resonance imaging of the normal bovine digit.

    PubMed

    Raji, A R; Sardari, K; Mirmahmoob, P

    2009-08-01

    The purpose of this study was defining the normal structures of the digits and hoof in Holstein dairy cattle using Magnetic Resonance Image (MRI). Transverse, Sagital and Dorsoplantar MRI images of three isolated cattle cadaver digits were obtained using Gyroscan T5-NT a magnet of 0.5 Tesla and T1 Weighted sequence. The MRI images were compared to corresponding frozen cross-sections and dissect specimens of the cadaver digits. Relevant anatomical structures were identified and labeled at each level. The MRI images provided anatomical detail of the digits and hoof in Holstein dairy cattle. Transversal images provided excellent depiction of anatomical structures when compared to corresponding frozen cross-sections. The information presented in this paper would serve as an initial reference to the evaluation of MRI images of the digits and hoof in Holstein dairy cattle, that can be used by radiologist, clinicians, surgeon or for research propose in bovine lameness.

  5. Quality initiatives: improving patient flow for a bone densitometry practice: results from a Mayo Clinic radiology quality initiative.

    PubMed

    Aakre, Kenneth T; Valley, Timothy B; O'Connor, Michael K

    2010-03-01

    Lean Six Sigma process improvement methodologies have been used in manufacturing for some time. However, Lean Six Sigma process improvement methodologies also are applicable to radiology as a way to identify opportunities for improvement in patient care delivery settings. A multidisciplinary team of physicians and staff conducted a 100-day quality improvement project with the guidance of a quality advisor. By using the framework of DMAIC (define, measure, analyze, improve, and control), time studies were performed for all aspects of patient and technologist involvement. From these studies, value stream maps for the current state and for the future were developed, and tests of change were implemented. Comprehensive value stream maps showed that before implementation of process changes, an average time of 20.95 minutes was required for completion of a bone densitometry study. Two process changes (ie, tests of change) were undertaken. First, the location for completion of a patient assessment form was moved from inside the imaging room to the waiting area, enabling patients to complete the form while waiting for the technologist. Second, the patient was instructed to sit in a waiting area immediately outside the imaging rooms, rather than in the main reception area, which is far removed from the imaging area. Realignment of these process steps, with reduced technologist travel distances, resulted in a 3-minute average decrease in the patient cycle time. This represented a 15% reduction in the initial patient cycle time with no change in staff or costs. Radiology process improvement projects can yield positive results despite small incremental changes.

  6. Effective Multifocus Image Fusion Based on HVS and BP Neural Network

    PubMed Central

    Yang, Yong

    2014-01-01

    The aim of multifocus image fusion is to fuse the images taken from the same scene with different focuses to obtain a resultant image with all objects in focus. In this paper, a novel multifocus image fusion method based on human visual system (HVS) and back propagation (BP) neural network is presented. Three features which reflect the clarity of a pixel are firstly extracted and used to train a BP neural network to determine which pixel is clearer. The clearer pixels are then used to construct the initial fused image. Thirdly, the focused regions are detected by measuring the similarity between the source images and the initial fused image followed by morphological opening and closing operations. Finally, the final fused image is obtained by a fusion rule for those focused regions. Experimental results show that the proposed method can provide better performance and outperform several existing popular fusion methods in terms of both objective and subjective evaluations. PMID:24683327

  7. Transport Imaging in the One Dimensional Limit

    DTIC Science & Technology

    2006-06-01

    Spatial luminescence from single bottom-up GaN and ZnO nanowires deposited by metal initiated metal -organic CVD on Au and SiO2 substrates is imaged. CL...this thesis were deposited by metal initiated metal -organic CVD on Au and SiO2 substrates . The process was carried out with different reagents in...are reported. Spatial luminescence from single bottom-up GaN and ZnO nanowires deposited by metal initiated metal -organic CVD on Au and SiO2

  8. Initial test of MITA/DIMM with an operational CBP system

    NASA Astrophysics Data System (ADS)

    Baldwin, Kevin; Hanna, Randall; Brown, Andrea; Brown, David; Moyer, Steven; Hixson, Jonathan G.

    2018-05-01

    The MITA (Motion Imagery Task Analyzer) project was conceived by CBP OA (Customs and Border Protection - Office of Acquisition) and executed by JHU/APL (Johns Hopkins University/Applied Physics Laboratory) and CERDEC NVESD MSD (Communications and Electronics Research Development Engineering Command Night Vision and Electronic Sensors Directorate Modeling and Simulation Division). The intent was to develop an efficient methodology whereby imaging system performance could be quickly and objectively characterized in a field setting. The initial design, development, and testing spanned a period of approximately 18 months with the initial project coming to a conclusion after testing of the MITA system in June 2017 with a fielded CBP system. The NVESD contribution to MITA was thermally heated target resolution boards deployed to support a range close to the sensor and, when possible, at range with the targets of interest. JHU/APL developed a laser DIMM (Differential Image Motion Monitor) system designed to measure the optical turbulence present along the line of sight of the imaging system during the time of image collection. The imagery collected of the target board was processed to calculate the in situ system resolution. This in situ imaging system resolution and the time-correlated turbulence measured by the DIMM system were used in NV-IPM (Night Vision Integrated Performance Model) to calculate the theoretical imaging system performance. Overall, this proves the MITA concept feasible. However, MITA is still in the initial phases of development and requires further verification and validation to ensure accuracy and reliability of both the instrument and the imaging system performance predictions.

  9. Object segmentation using graph cuts and active contours in a pyramidal framework

    NASA Astrophysics Data System (ADS)

    Subudhi, Priyambada; Mukhopadhyay, Susanta

    2018-03-01

    Graph cuts and active contours are two very popular interactive object segmentation techniques in the field of computer vision and image processing. However, both these approaches have their own well-known limitations. Graph cut methods perform efficiently giving global optimal segmentation result for smaller images. However, for larger images, huge graphs need to be constructed which not only takes an unacceptable amount of memory but also increases the time required for segmentation to a great extent. On the other hand, in case of active contours, initial contour selection plays an important role in the accuracy of the segmentation. So a proper selection of initial contour may improve the complexity as well as the accuracy of the result. In this paper, we have tried to combine these two approaches to overcome their above-mentioned drawbacks and develop a fast technique of object segmentation. Here, we have used a pyramidal framework and applied the mincut/maxflow algorithm on the lowest resolution image with the least number of seed points possible which will be very fast due to the smaller size of the image. Then, the obtained segmentation contour is super-sampled and and worked as the initial contour for the next higher resolution image. As the initial contour is very close to the actual contour, so fewer number of iterations will be required for the convergence of the contour. The process is repeated for all the high-resolution images and experimental results show that our approach is faster as well as memory efficient as compare to both graph cut or active contour segmentation alone.

  10. The Image of Mathematics Held by Irish Post-Primary Students

    ERIC Educational Resources Information Center

    Lane, Ciara; Stynes, Martin; O'Donoghue, John

    2014-01-01

    The image of mathematics held by Irish post-primary students was examined and a model for the image found was constructed. Initially, a definition for "image of mathematics" was adopted with image of mathematics hypothesized as comprising attitudes, beliefs, self-concept, motivation, emotions and past experiences of mathematics. Research…

  11. Ultrasonographic imaging of inflammatory bowel disease in pediatric patients

    PubMed Central

    Chiorean, Liliana; Schreiber-Dietrich, Dagmar; Braden, Barbara; Cui, Xin-Wu; Buchhorn, Reiner; Chang, Jian-Min; Dietrich, Christoph F

    2015-01-01

    Inflammatory bowel disease (IBD) is one of the most common chronic gastrointestinal diseases in pediatric patients. Choosing the optimal imaging modality for the assessment of gastrointestinal disease in pediatric patients can be challenging. The invasiveness and patient acceptance, the radiation exposure and the quality performance of the diagnostic test need to be considered. By reviewing the literature regarding imaging in inflammatory bowel disease the value of ultrasound in the clinical management of pediatric patients is highlighted. Transabdominal ultrasound is a useful, noninvasive method for the initial diagnosis of IBD in children; it also provides guidance for therapeutic decisions and helps to characterize and predict the course of the disease in individual patients. Ultrasound techniques including color Doppler imaging and contrast-enhanced ultrasound are promising imaging tools to determine disease activity and complications. Comparative studies between different imaging methods are needed. PMID:25954096

  12. Techniques for identifying dust devils in mars pathfinder images

    USGS Publications Warehouse

    Metzger, S.M.; Carr, J.R.; Johnson, J. R.; Parker, T.J.; Lemmon, M.T.

    2000-01-01

    Image processing methods used to identify and enhance dust devil features imaged by IMP (Imager for Mars Pathfinder) are reviewed. Spectral differences, visible red minus visible blue, were used for initial dust devil searches, driven by the observation that Martian dust has high red and low blue reflectance. The Martian sky proved to be more heavily dust-laden than pre-Pathfinder predictions, based on analysis of images from the Hubble Space Telescope. As a result, these initial spectral difference methods failed to contrast dust devils with background dust haze. Imager artifacts (dust motes on the camera lens, flat-field effects caused by imperfections in the CCD, and projection onto a flat sensor plane by a convex lens) further impeded the ability to resolve subtle dust devil features. Consequently, reference images containing sky with a minimal horizon were first subtracted from each spectral filter image to remove camera artifacts and reduce the background dust haze signal. Once the sky-flat preprocessing step was completed, the red-minus-blue spectral difference scheme was attempted again. Dust devils then were successfully identified as bright plumes. False-color ratios using calibrated IMP images were found useful for visualizing dust plumes, verifying initial discoveries as vortex-like features. Enhancement of monochromatic (especially blue filter) images revealed dust devils as silhouettes against brighter background sky. Experiments with principal components transformation identified dust devils in raw, uncalibrated IMP images and further showed relative movement of dust devils across the Martian surface. A variety of methods therefore served qualitative and quantitative goals for dust plume identification and analysis in an environment where such features are obscure.

  13. Multiple recurrent ischaemic strokes in a patient with cancer: is there a role for the initiation of anticoagulation therapy for secondary stroke prevention?

    PubMed Central

    Suero-Abreu, Giselle Alexandra; Cheng, Jia Zhen; Then, Ryna Karina

    2017-01-01

    A 52-year-old woman with a medical history of cervical and thyroid cancer, hypertension, dyslipidaemia, uncontrolled diabetes and heavy smoking was diagnosed with a new metastatic cholangiocarcinoma. While undergoing palliative chemotherapy, she developed dysarthria and left-sided weakness. Imaging studies showed multiple bilateral ischaemic strokes. On hospital days 2 and 5, she developed worsening neurological symptoms and imaging studies revealed new areas of ischaemia on respective days. Subsequent workup did not revealed a clear aetiology for the multiple ischaemic events and hypercoagulability studies were only significant for a mildly elevated serum D-dimer level. Although guidelines are unclear, full-dose anticoagulation with low molecular weight heparin was initiated given her high risk of stroke recurrence. She was discharged to acute rehabilitation but, within a month, she experienced complications of her malignant disease progression and a new pulmonary thromboembolism. The patient died soon after being discharged home with hospice care. PMID:28578306

  14. Application of Prostate Imaging Reporting and Data System Version 2 (PI-RADS v2): Interobserver Agreement and Positive Predictive Value for Localization of Intermediate- and High-Grade Prostate Cancers on Multiparametric Magnetic Resonance Imaging.

    PubMed

    Chen, Frank; Cen, Steven; Palmer, Suzanne

    2017-09-01

    To evaluate interobserver agreement with the use of and the positive predictive value (PPV) of Prostate Imaging Reporting and Data System version 2 (PI-RADS v2) for the localization of intermediate- and high-grade prostate cancers on multiparametric magnetic resonance imaging (mpMRI). In this retrospective, institutional review board-approved study, 131 consecutive patients who had mpMRI followed by transrectal ultrasound-MR imaging fusion-guided biopsy of the prostate were included. Two readers who were blinded to initial mpMRI reports, clinical data, and pathologic outcomes reviewed the MR images, identified all prostate lesions, and scored each lesion based on the PI-RADS v2. Interobserver agreement was assessed by intraclass correlation coefficient (ICC), and PPV was calculated for each PI-RADS category. PI-RADS v2 was found to have a moderate level of interobserver agreement between two readers of varying experience, with ICC of 0.74, 0.72, and 0.67 for all lesions, peripheral zone lesions, and transitional zone lesions, respectively. Despite only moderate interobserver agreement, the calculated PPV in the detection of intermediate- and high-grade prostate cancers for each PI-RADS category was very similar between the two readers, with approximate PPV of 0%, 12%, 64%, and 87% for PI-RADS categories 2, 3, 4, and 5, respectively. In our study, PI-RADS v2 has only moderate interobserver agreement, a similar finding in studies of the original PI-RADS and in initial studies of PI-RADS v2. Despite this, PI-RADS v2 appears to be a useful system to predict significant prostate cancer, with PI-RADS scores correlating well with the likelihood of intermediate- and high-grade cancers. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  15. Initial clinical testing of a multi-spectral imaging system built on a smartphone platform

    NASA Astrophysics Data System (ADS)

    Mink, Jonah W.; Wexler, Shraga; Bolton, Frank J.; Hummel, Charles; Kahn, Bruce S.; Levitz, David

    2016-03-01

    Multi-spectral imaging systems are often expensive and bulky. An innovative multi-spectral imaging system was fitted onto a mobile colposcope, an imaging system built around a smartphone in order to image the uterine cervix from outside the body. The multi-spectral mobile colposcope (MSMC) acquires images at different wavelengths. This paper presents the clinical testing of MSMC imaging (technical validation of the MSMC system is described elsewhere 1 ). Patients who were referred to colposcopy following abnormal screening test (Pap or HPV DNA test) according to the standard of care were enrolled. Multi-spectral image sets of the cervix were acquired, consisting of images from the various wavelengths. Image acquisition took 1-2 sec. Areas suspected for dysplasia under white light imaging were biopsied, according to the standard of care. Biopsied sites were recorded on a clockface map of the cervix. Following the procedure, MSMC data was processed from the sites of biopsied sites. To date, the initial histopathological results are still outstanding. Qualitatively, structures in the cervical images were sharper at lower wavelengths than higher wavelengths. Patients tolerated imaging well. The result suggests MSMC holds promise for cervical imaging.

  16. The Progression of Haze Formation in Rabbit Corneas Following Phototherapeutic Keratectomy

    PubMed Central

    Gibson, Daniel J.; Tuli, Sonal S.; Schultz, Gregory S.

    2013-01-01

    Purpose. To determine the topographical location and time course of development of corneal haze in a phototherapeutic keratectomy model using slit lamp examination, macrophotography, quantitative image analysis, and immunofluorescence staining of corneal sections. Methods. Rabbit corneas were ablated with an excimer laser and were observed and graded for haze via slit lamp, imaged, and graded by macrophotography. Corneal sections were stained for α-smooth muscle actin (α-SMA) and tenascin-C (TNC). The distribution of haze imaged in the macrophotographs and density of α-SMA and TNC staining were compared. A daily image time course of haze formation was generated using macrophotography. Results. The first signs of corneal haze were apparent shortly after reepithelialization. The haze was distributed as a ring at the wound margin in all cases, while nearly all corneas also had some central islands of haze initiation. With time, the haze spread within the ablated zone and intensified. The pattern of immunofluorescent staining for α-SMA and TNC at the wound margin mirrored the haze distribution, spread, and intensification with time. Conclusions. The initiation and spread of subepithelial haze begins shortly after reepithelialization. The haze then spreads from the loci of initiation and becomes more dense with time, maturing as early as 14 days after wounding. The improved temporal and spatial resolution provided by these data improve the current model of light-scattering haze formation in wounded corneas, which will improve the design of studies aimed at maintaining corneal clarity following acute injury or surgery. PMID:23800768

  17. Efficient threshold for volumetric segmentation

    NASA Astrophysics Data System (ADS)

    Burdescu, Dumitru D.; Brezovan, Marius; Stanescu, Liana; Stoica Spahiu, Cosmin; Ebanca, Daniel

    2015-07-01

    Image segmentation plays a crucial role in effective understanding of digital images. However, the research on the existence of general purpose segmentation algorithm that suits for variety of applications is still very much active. Among the many approaches in performing image segmentation, graph based approach is gaining popularity primarily due to its ability in reflecting global image properties. Volumetric image segmentation can simply result an image partition composed by relevant regions, but the most fundamental challenge in segmentation algorithm is to precisely define the volumetric extent of some object, which may be represented by the union of multiple regions. The aim in this paper is to present a new method to detect visual objects from color volumetric images and efficient threshold. We present a unified framework for volumetric image segmentation and contour extraction that uses a virtual tree-hexagonal structure defined on the set of the image voxels. The advantage of using a virtual tree-hexagonal network superposed over the initial image voxels is that it reduces the execution time and the memory space used, without losing the initial resolution of the image.

  18. Using New Maps to Navigate Cancer Treatment - TCGA

    Cancer.gov

    Drs.Scott Hwang and Chad Holder of Emory University discuss the development of VARSARI and The Cancer Imaging Program's TCGA Radiology Initiative. Learn more about their and Dr. Carl Jaffe's work in this TCGA In Action Case Study.

  19. Missed rib fractures on evaluation of initial chest CT for trauma patients: pattern analysis and diagnostic value of coronal multiplanar reconstruction images with multidetector row CT

    PubMed Central

    Cho, S H; Sung, Y M; Kim, M S

    2012-01-01

    Objective The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. Methods 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. Results 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Conclusion Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images. PMID:22514102

  20. Automatic bone outer contour extraction from B-modes ultrasound images based on local phase symmetry and quadratic polynomial fitting

    NASA Astrophysics Data System (ADS)

    Karlita, Tita; Yuniarno, Eko Mulyanto; Purnama, I. Ketut Eddy; Purnomo, Mauridhi Hery

    2017-06-01

    Analyzing ultrasound (US) images to get the shapes and structures of particular anatomical regions is an interesting field of study since US imaging is a non-invasive method to capture internal structures of a human body. However, bone segmentation of US images is still challenging because it is strongly influenced by speckle noises and it has poor image quality. This paper proposes a combination of local phase symmetry and quadratic polynomial fitting methods to extract bone outer contour (BOC) from two dimensional (2D) B-modes US image as initial steps of three-dimensional (3D) bone surface reconstruction. By using local phase symmetry, the bone is initially extracted from US images. BOC is then extracted by scanning one pixel on the bone boundary in each column of the US images using first phase features searching method. Quadratic polynomial fitting is utilized to refine and estimate the pixel location that fails to be detected during the extraction process. Hole filling method is then applied by utilize the polynomial coefficients to fill the gaps with new pixel. The proposed method is able to estimate the new pixel position and ensures smoothness and continuity of the contour path. Evaluations are done using cow and goat bones by comparing the resulted BOCs with the contours produced by manual segmentation and contours produced by canny edge detection. The evaluation shows that our proposed methods produces an excellent result with average MSE before and after hole filling at the value of 0.65.

  1. Deformable registration of the inflated and deflated lung in cone-beam CT-guided thoracic surgery: Initial investigation of a combined model- and image-driven approach

    PubMed Central

    Uneri, Ali; Nithiananthan, Sajendra; Schafer, Sebastian; Otake, Yoshito; Stayman, J. Webster; Kleinszig, Gerhard; Sussman, Marc S.; Prince, Jerry L.; Siewerdsen, Jeffrey H.

    2013-01-01

    Purpose: Surgical resection is the preferred modality for curative treatment of early stage lung cancer, but localization of small tumors (<10 mm diameter) during surgery presents a major challenge that is likely to increase as more early-stage disease is detected incidentally and in low-dose CT screening. To overcome the difficulty of manual localization (fingers inserted through intercostal ports) and the cost, logistics, and morbidity of preoperative tagging (coil or dye placement under CT-fluoroscopy), the authors propose the use of intraoperative cone-beam CT (CBCT) and deformable image registration to guide targeting of small tumors in video-assisted thoracic surgery (VATS). A novel algorithm is reported for registration of the lung from its inflated state (prior to pleural breach) to the deflated state (during resection) to localize surgical targets and adjacent critical anatomy. Methods: The registration approach geometrically resolves images of the inflated and deflated lung using a coarse model-driven stage followed by a finer image-driven stage. The model-driven stage uses image features derived from the lung surfaces and airways: triangular surface meshes are morphed to capture bulk motion; concurrently, the airways generate graph structures from which corresponding nodes are identified. Interpolation of the sparse motion fields computed from the bounding surface and interior airways provides a 3D motion field that coarsely registers the lung and initializes the subsequent image-driven stage. The image-driven stage employs an intensity-corrected, symmetric form of the Demons method. The algorithm was validated over 12 datasets, obtained from porcine specimen experiments emulating CBCT-guided VATS. Geometric accuracy was quantified in terms of target registration error (TRE) in anatomical targets throughout the lung, and normalized cross-correlation. Variations of the algorithm were investigated to study the behavior of the model- and image-driven stages by modifying individual algorithmic steps and examining the effect in comparison to the nominal process. Results: The combined model- and image-driven registration process demonstrated accuracy consistent with the requirements of minimally invasive VATS in both target localization (∼3–5 mm within the target wedge) and critical structure avoidance (∼1–2 mm). The model-driven stage initialized the registration to within a median TRE of 1.9 mm (95% confidence interval (CI) maximum = 5.0 mm), while the subsequent image-driven stage yielded higher accuracy localization with 0.6 mm median TRE (95% CI maximum = 4.1 mm). The variations assessing the individual algorithmic steps elucidated the role of each step and in some cases identified opportunities for further simplification and improvement in computational speed. Conclusions: The initial studies show the proposed registration method to successfully register CBCT images of the inflated and deflated lung. Accuracy appears sufficient to localize the target and adjacent critical anatomy within ∼1–2 mm and guide localization under conditions in which the target cannot be discerned directly in CBCT (e.g., subtle, nonsolid tumors). The ability to directly localize tumors in the operating room could provide a valuable addition to the VATS arsenal, obviate the cost, logistics, and morbidity of preoperative tagging, and improve patient safety. Future work includes in vivo testing, optimization of workflow, and integration with a CBCT image guidance system. PMID:23298134

  2. Deformable registration of the inflated and deflated lung in cone-beam CT-guided thoracic surgery: initial investigation of a combined model- and image-driven approach.

    PubMed

    Uneri, Ali; Nithiananthan, Sajendra; Schafer, Sebastian; Otake, Yoshito; Stayman, J Webster; Kleinszig, Gerhard; Sussman, Marc S; Prince, Jerry L; Siewerdsen, Jeffrey H

    2013-01-01

    Surgical resection is the preferred modality for curative treatment of early stage lung cancer, but localization of small tumors (<10 mm diameter) during surgery presents a major challenge that is likely to increase as more early-stage disease is detected incidentally and in low-dose CT screening. To overcome the difficulty of manual localization (fingers inserted through intercostal ports) and the cost, logistics, and morbidity of preoperative tagging (coil or dye placement under CT-fluoroscopy), the authors propose the use of intraoperative cone-beam CT (CBCT) and deformable image registration to guide targeting of small tumors in video-assisted thoracic surgery (VATS). A novel algorithm is reported for registration of the lung from its inflated state (prior to pleural breach) to the deflated state (during resection) to localize surgical targets and adjacent critical anatomy. The registration approach geometrically resolves images of the inflated and deflated lung using a coarse model-driven stage followed by a finer image-driven stage. The model-driven stage uses image features derived from the lung surfaces and airways: triangular surface meshes are morphed to capture bulk motion; concurrently, the airways generate graph structures from which corresponding nodes are identified. Interpolation of the sparse motion fields computed from the bounding surface and interior airways provides a 3D motion field that coarsely registers the lung and initializes the subsequent image-driven stage. The image-driven stage employs an intensity-corrected, symmetric form of the Demons method. The algorithm was validated over 12 datasets, obtained from porcine specimen experiments emulating CBCT-guided VATS. Geometric accuracy was quantified in terms of target registration error (TRE) in anatomical targets throughout the lung, and normalized cross-correlation. Variations of the algorithm were investigated to study the behavior of the model- and image-driven stages by modifying individual algorithmic steps and examining the effect in comparison to the nominal process. The combined model- and image-driven registration process demonstrated accuracy consistent with the requirements of minimally invasive VATS in both target localization (∼3-5 mm within the target wedge) and critical structure avoidance (∼1-2 mm). The model-driven stage initialized the registration to within a median TRE of 1.9 mm (95% confidence interval (CI) maximum = 5.0 mm), while the subsequent image-driven stage yielded higher accuracy localization with 0.6 mm median TRE (95% CI maximum = 4.1 mm). The variations assessing the individual algorithmic steps elucidated the role of each step and in some cases identified opportunities for further simplification and improvement in computational speed. The initial studies show the proposed registration method to successfully register CBCT images of the inflated and deflated lung. Accuracy appears sufficient to localize the target and adjacent critical anatomy within ∼1-2 mm and guide localization under conditions in which the target cannot be discerned directly in CBCT (e.g., subtle, nonsolid tumors). The ability to directly localize tumors in the operating room could provide a valuable addition to the VATS arsenal, obviate the cost, logistics, and morbidity of preoperative tagging, and improve patient safety. Future work includes in vivo testing, optimization of workflow, and integration with a CBCT image guidance system.

  3. Investigating Image Formation with a Camera Obscura: a Study in Initial Primary Science Teacher Education

    NASA Astrophysics Data System (ADS)

    Muñoz-Franco, Granada; Criado, Ana María; García-Carmona, Antonio

    2018-04-01

    This article presents the results of a qualitative study aimed at determining the effectiveness of the camera obscura as a didactic tool to understand image formation (i.e., how it is possible to see objects and how their image is formed on the retina, and what the image formed on the retina is like compared to the object observed) in a context of scientific inquiry. The study involved 104 prospective primary teachers (PPTs) who were being trained in science teaching. To assess the effectiveness of this tool, an open questionnaire was applied before (pre-test) and after (post-test) the educational intervention. The data were analyzed by combining methods of inter- and intra-rater analysis. The results showed that more than half of the PPTs advanced in their ideas towards the desirable level of knowledge in relation to the phenomena studied. The conclusion reached is that the camera obscura, used in a context of scientific inquiry, is a useful tool for PPTs to improve their knowledge about image formation and experience in the first person an authentic scientific inquiry during their teacher training.

  4. Real-Time Confocal Imaging Of The Living Eye

    NASA Astrophysics Data System (ADS)

    Jester, James V.; Cavanagh, H. Dwight; Essepian, John; Shields, William J.; Lemp, Michael A.

    1989-12-01

    In 1986, we adapted the Tandem Scanning Reflected Light Microscope of Petran and Hadraysky to permit non-invasive, confocal imaging of the living eye in real-time. We were first to obtain stable, confocal optical sections in vivo, from human and animal eyes. Using confocal imaging systems we have now studied living, normal volunteers, rabbits, cats and primates sequentially, non-invasively, and in real-time. The continued development of real-time confocal imaging systems will unlock the door to a new field of cell biology involving for the first time the study of dynamic cellular processes in living organ systems. Towards this end we have concentrated our initial studies on three areas (1) evaluation of confocal microscope systems for real-time image acquisition, (2) studies of the living normal cornea (epithelium, stroma, endothelium) in human and other species; and (3) sequential wound-healing responses in the cornea in single animals to lamellar-keratectomy injury (cellular migration, inflammation, scarring). We believe that this instrument represents an important, new paradigm for research in cell biology and pathology and that it will fundamentally alter all experimental and clinical approaches in future years.

  5. Confocal microendoscopy: Characterization of imaging bundles, fluorescent contrast agents, and early clinical results

    NASA Astrophysics Data System (ADS)

    Udovich, Joshua Anthony

    Ovarian cancer is the fifth leading cause of cancer related deaths among women. Early detection improves the chances of survival following diagnosis, and new imaging modalities have the potential to reduce deaths due to this disease. The confocal microendoscope (CME) is a non-destructive in-vivo imaging device for visualization of the ovaries that operates in real-time. Two components of the CME system are evaluated in this paper, and initial results from an ongoing clinical trial are presented. Fiber-optic imaging bundles are used in the CME imaging catheter to relay images over distances of up to 20 feet. When detecting fluorescent signals from investigated tissue, any fluorescence in the system can potentially reduce contrast in images. The emission and transmission properties of three commercially available fiber optic imaging bundles were evaluated. Emission maps of fluorescence from bundles were generated at multiple excitation wavelengths to determine the profile and amount of fluorescence present in bundles manufactured by Sumitomo, Fujikura, and Schott. Results are also presented that show the variation of transmittance as a function of illumination angle in these bundles. Users of high-resolution fiber-optic imaging bundles should be aware of these properties and take them into account during system design. Contrast is improved in images obtained with the CME through the application of topical dyes. Acridine orange (AO) and SYTO 16 are two fluorescent stains that are used to show the size, shape, and distribution of cell nuclei. Unfortunately, little is known about the effects of these dyes on living tissues. This study was undertaken to evaluate the effects of dye treatment on peritoneal tissues in mice. Seventy-five Balb/c mice were split into five groups of fifteen and given peritoneal injections of dye or saline. The proportions of negative outcomes for the control and test groups were compared using confidence intervals and the Fisher's exact test. No significant difference was determined between the groups. These data provide preliminary results on determining the effect of these dyes on living tissues. Preliminary results of a clinical trial are presented showing in-vivo use of the CME for imaging of the ovaries. This is the first portion of a two part study to demonstrate the clinical diagnosis potential of the CME system. A mobile version of the bench-top CME was modified to be used in the clinic. Fluorescein sodium is used as an initial contrast agent in these studies to demonstrate fluorescence imaging. Twenty patients were successfully imaged, and results of this study have allowed progression to a clinical validation study showing the diagnostic capabilities of the CME.

  6. Development of a novel imaging informatics-based system with an intelligent workflow engine (IWEIS) to support imaging-based clinical trials

    PubMed Central

    Wang, Ximing; Liu, Brent J; Martinez, Clarisa; Zhang, Xuejun; Winstein, Carolee J

    2015-01-01

    Imaging based clinical trials can benefit from a solution to efficiently collect, analyze, and distribute multimedia data at various stages within the workflow. Currently, the data management needs of these trials are typically addressed with custom-built systems. However, software development of the custom- built systems for versatile workflows can be resource-consuming. To address these challenges, we present a system with a workflow engine for imaging based clinical trials. The system enables a project coordinator to build a data collection and management system specifically related to study protocol workflow without programming. Web Access to DICOM Objects (WADO) module with novel features is integrated to further facilitate imaging related study. The system was initially evaluated by an imaging based rehabilitation clinical trial. The evaluation shows that the cost of the development of system can be much reduced compared to the custom-built system. By providing a solution to customize a system and automate the workflow, the system will save on development time and reduce errors especially for imaging clinical trials. PMID:25870169

  7. Implementation and applications of dual-modality imaging

    NASA Astrophysics Data System (ADS)

    Hasegawa, Bruce H.; Barber, William C.; Funk, Tobias; Hwang, Andrew B.; Taylor, Carmen; Sun, Mingshan; Seo, Youngho

    2004-06-01

    In medical diagnosis, functional or physiological data can be acquired using radionuclide imaging with positron emission tomography or with single-photon emission computed tomography. However, anatomical or structural data can be acquired using X-ray computed tomography. In dual-modality imaging, both radionuclide and X-ray detectors are incorporated in an imaging system to allow both functional and structural data to be acquired in a single procedure without removing the patient from the imaging system. In a clinical setting, dual-modality imaging systems commonly are used to localize radiopharmaceutical uptake with respect to the patient's anatomy. This helps the clinician to differentiate disease from regions of normal radiopharmaceutical accumulation, to improve diagnosis or cancer staging, or to facilitate planning for radiation therapy or surgery. While initial applications of dual-modality imaging were developed for clinical imaging on humans, it now is recognized that these systems have potentially important applications for imaging small animals involved in experimental studies including basic investigations of mammalian biology and development of new pharmaceuticals for diagnosis or treatment of disease.

  8. Parameter Search Algorithms for Microwave Radar-Based Breast Imaging: Focal Quality Metrics as Fitness Functions.

    PubMed

    O'Loughlin, Declan; Oliveira, Bárbara L; Elahi, Muhammad Adnan; Glavin, Martin; Jones, Edward; Popović, Milica; O'Halloran, Martin

    2017-12-06

    Inaccurate estimation of average dielectric properties can have a tangible impact on microwave radar-based breast images. Despite this, recent patient imaging studies have used a fixed estimate although this is known to vary from patient to patient. Parameter search algorithms are a promising technique for estimating the average dielectric properties from the reconstructed microwave images themselves without additional hardware. In this work, qualities of accurately reconstructed images are identified from point spread functions. As the qualities of accurately reconstructed microwave images are similar to the qualities of focused microscopic and photographic images, this work proposes the use of focal quality metrics for average dielectric property estimation. The robustness of the parameter search is evaluated using experimental dielectrically heterogeneous phantoms on the three-dimensional volumetric image. Based on a very broad initial estimate of the average dielectric properties, this paper shows how these metrics can be used as suitable fitness functions in parameter search algorithms to reconstruct clear and focused microwave radar images.

  9. An automatic segmentation method of a parameter-adaptive PCNN for medical images.

    PubMed

    Lian, Jing; Shi, Bin; Li, Mingcong; Nan, Ziwei; Ma, Yide

    2017-09-01

    Since pre-processing and initial segmentation steps in medical images directly affect the final segmentation results of the regions of interesting, an automatic segmentation method of a parameter-adaptive pulse-coupled neural network is proposed to integrate the above-mentioned two segmentation steps into one. This method has a low computational complexity for different kinds of medical images and has a high segmentation precision. The method comprises four steps. Firstly, an optimal histogram threshold is used to determine the parameter [Formula: see text] for different kinds of images. Secondly, we acquire the parameter [Formula: see text] according to a simplified pulse-coupled neural network (SPCNN). Thirdly, we redefine the parameter V of the SPCNN model by sub-intensity distribution range of firing pixels. Fourthly, we add an offset [Formula: see text] to improve initial segmentation precision. Compared with the state-of-the-art algorithms, the new method achieves a comparable performance by the experimental results from ultrasound images of the gallbladder and gallstones, magnetic resonance images of the left ventricle, and mammogram images of the left and the right breast, presenting the overall metric UM of 0.9845, CM of 0.8142, TM of 0.0726. The algorithm has a great potential to achieve the pre-processing and initial segmentation steps in various medical images. This is a premise for assisting physicians to detect and diagnose clinical cases.

  10. Approaches to inspecting computed tomographic and magnetic resonance studies.

    PubMed

    Lamb, Christopher R; Dale, Vicki H M

    2013-01-01

    There is a need to better understand how to optimally inspect large image datasets. The aim of the present study was to complement experimental studies of visual perception by using an online questionnaire to collect opinions of practicing veterinary radiologists about the approaches they use when inspecting clinical computed X-ray tomography (CT) and/or magnetic resonance (MR) studies, and to test associations between radiologist's approaches and their training, experience, or caseload. Questionnaires were received from 90/454 (20%) American College of Veterinary Radiology (ACVR) Diplomates and 58/156 (37%) European College of Veterinary Diagnostic Imaging (ECVDI) Diplomates, providing 139 complete responses for CT studies and 116 for MR. Questionnaire responses differed for the following variables: specialty college, years since Board Certification, CT and MR caseload, and type of practice. ACVR Diplomates more frequently inspected multiple anatomic structures in CT and MR images before moving on to the next image, and ECVDI Diplomates more frequently inspected a specific anatomic structure through a series, then went back and checked another structure. A significant number of radiologists indicated that they initially ignore the history, adopt relatively rigid search patterns with emphasis on viewing images in a predetermined order with minimal deviation, and arrange series of images to facilitate comparisons between images, such as pre- and postcontrast images. Radiologists tended to adopt similar approaches for both CT and MR studies. Findings from this study could be used as foci for teaching novices how to approach large imaging studies, and provide guidance for case-based assessment of trainees. © 2013 Veterinary Radiology & Ultrasound.

  11. Understanding the Role of Hemodynamics in the Initiation, Progression, Rupture, and Treatment Outcome of Cerebral Aneurysm from Medical Image-Based Computational Studies

    PubMed Central

    Castro, Marcelo A.

    2013-01-01

    About a decade ago, the first image-based computational hemodynamic studies of cerebral aneurysms were presented. Their potential for clinical applications was the result of a right combination of medical image processing, vascular reconstruction, and grid generation techniques used to reconstruct personalized domains for computational fluid and solid dynamics solvers and data analysis and visualization techniques. A considerable number of studies have captivated the attention of clinicians, neurosurgeons, and neuroradiologists, who realized the ability of those tools to help in understanding the role played by hemodynamics in the natural history and management of intracranial aneurysms. This paper intends to summarize the most relevant results in the field reported during the last years. PMID:24967285

  12. Normal cross-sectional anatomy of the bovine digit: comparison of computed tomography and limb anatomy.

    PubMed

    Raji, A R; Sardari, K; Mohammadi, H R

    2008-06-01

    The purpose of this study was to define the structures of the digits and hoof in Holstein dairy cattle by using computed tomography scan (CT scan). Transverse, sagittal and dorsoplantar CT images of two isolated cattle cadaver digits were obtained using a Siemens ARTX2 Somatom. The CT images were compared to corresponding frozen cross-sections. Relevant anatomical structures were identified and labelled at each level. The CT images provided anatomical detail of the digits and hoof in Holstein dairy cattle. Transversal images provided excellent depiction of anatomical structures when compared to corresponding frozen cross-sections. The information presented in this paper would serve as an initial reference to the evaluation of CT images of the digits and hoof in Holstein dairy cattle.

  13. Neuroradiology Using Secure Mobile Device Review.

    PubMed

    Randhawa, Privia A; Morrish, William; Lysack, John T; Hu, William; Goyal, Mayank; Hill, Michael D

    2016-04-05

    Image review on computer-based workstations has made film-based review outdated. Despite advances in technology, the lack of portability of digital workstations creates an inherent disadvantage. As such, we sought to determine if the quality of image review on a handheld device is adequate for routine clinical use. Six CT/CTA cases and six MR/MRA cases were independently reviewed by three neuroradiologists in varying environments: high and low ambient light using a handheld device and on a traditional imaging workstation in ideal conditions. On first review (using a handheld device in high ambient light), a preliminary diagnosis for each case was made. Upon changes in review conditions, neuroradiologists were asked if any additional features were seen that changed their initial diagnoses. Reviewers were also asked to comment on overall clinical quality and if the handheld display was of acceptable quality for image review. After the initial CT review in high ambient light, additional findings were reported in 2 of 18 instances on subsequent reviews. Similarly, additional findings were identified in 4 of 18 instances after the initial MR review in high ambient lighting. Only one of these six additional findings contributed to the diagnosis made on the initial preliminary review. Use of a handheld device for image review is of adequate diagnostic quality based on image contrast, sharpness of structures, visible artefacts and overall display quality. Although reviewers were comfortable with using this technology, a handheld device with a larger screen may be diagnostically superior.

  14. Comparative evaluation of two dose optimization methods for image-guided, highly-conformal, tandem and ovoids cervix brachytherapy planning

    NASA Astrophysics Data System (ADS)

    Ren, Jiyun; Menon, Geetha; Sloboda, Ron

    2013-04-01

    Although the Manchester system is still extensively used to prescribe dose in brachytherapy (BT) for locally advanced cervix cancer, many radiation oncology centers are transitioning to 3D image-guided BT, owing to the excellent anatomy definition offered by modern imaging modalities. As automatic dose optimization is highly desirable for 3D image-based BT, this study comparatively evaluates the performance of two optimization methods used in BT treatment planning—Nelder-Mead simplex (NMS) and simulated annealing (SA)—for a cervix BT computer simulation model incorporating a Manchester-style applicator. Eight model cases were constructed based on anatomical structure data (for high risk-clinical target volume (HR-CTV), bladder, rectum and sigmoid) obtained from measurements on fused MR-CT images for BT patients. D90 and V100 for HR-CTV, D2cc for organs at risk (OARs), dose to point A, conformation index and the sum of dwell times within the tandem and ovoids were calculated for optimized treatment plans designed to treat the HR-CTV in a highly conformal manner. Compared to the NMS algorithm, SA was found to be superior as it could perform optimization starting from a range of initial dwell times, while the performance of NMS was strongly dependent on their initial choice. SA-optimized plans also exhibited lower D2cc to OARs, especially the bladder and sigmoid, and reduced tandem dwell times. For cases with smaller HR-CTV having good separation from adjoining OARs, multiple SA-optimized solutions were found which differed markedly from each other and were associated with different choices for initial dwell times. Finally and importantly, the SA method yielded plans with lower dwell time variability compared with the NMS method.

  15. Multi-atlas learner fusion: An efficient segmentation approach for large-scale data.

    PubMed

    Asman, Andrew J; Huo, Yuankai; Plassard, Andrew J; Landman, Bennett A

    2015-12-01

    We propose multi-atlas learner fusion (MLF), a framework for rapidly and accurately replicating the highly accurate, yet computationally expensive, multi-atlas segmentation framework based on fusing local learners. In the largest whole-brain multi-atlas study yet reported, multi-atlas segmentations are estimated for a training set of 3464 MR brain images. Using these multi-atlas estimates we (1) estimate a low-dimensional representation for selecting locally appropriate example images, and (2) build AdaBoost learners that map a weak initial segmentation to the multi-atlas segmentation result. Thus, to segment a new target image we project the image into the low-dimensional space, construct a weak initial segmentation, and fuse the trained, locally selected, learners. The MLF framework cuts the runtime on a modern computer from 36 h down to 3-8 min - a 270× speedup - by completely bypassing the need for deformable atlas-target registrations. Additionally, we (1) describe a technique for optimizing the weak initial segmentation and the AdaBoost learning parameters, (2) quantify the ability to replicate the multi-atlas result with mean accuracies approaching the multi-atlas intra-subject reproducibility on a testing set of 380 images, (3) demonstrate significant increases in the reproducibility of intra-subject segmentations when compared to a state-of-the-art multi-atlas framework on a separate reproducibility dataset, (4) show that under the MLF framework the large-scale data model significantly improve the segmentation over the small-scale model under the MLF framework, and (5) indicate that the MLF framework has comparable performance as state-of-the-art multi-atlas segmentation algorithms without using non-local information. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Atmospheric Motion Vectors from INSAT-3D: Initial quality assessment and its impact on track forecast of cyclonic storm NANAUK

    NASA Astrophysics Data System (ADS)

    Deb, S. K.; Kishtawal, C. M.; Kumar, Prashant; Kiran Kumar, A. S.; Pal, P. K.; Kaushik, Nitesh; Sangar, Ghansham

    2016-03-01

    The advanced Indian meteorological geostationary satellite INSAT-3D was launched on 26 July 2013 with an improved imager and an infrared sounder and is placed at 82°E over the Indian Ocean region. With the advancement in retrieval techniques of different atmospheric parameters and with improved imager data have enhanced the scope for better understanding of the different tropical atmospheric processes over this region. The retrieval techniques and accuracy of one such parameter, Atmospheric Motion Vectors (AMV) has improved significantly with the availability of improved spatial resolution data along with more options of spectral channels in the INSAT-3D imager. The present work is mainly focused on providing brief descriptions of INSAT-3D data and AMV derivation processes using these data. It also discussed the initial quality assessment of INSAT-3D AMVs for a period of six months starting from 01 February 2014 to 31 July 2014 with other independent observations: i) Meteosat-7 AMVs available over this region, ii) in-situ radiosonde wind measurements, iii) cloud tracked winds from Multi-angle Imaging Spectro-Radiometer (MISR) and iv) numerical model analysis. It is observed from this study that the qualities of newly derived INSAT-3D AMVs are comparable with existing two versions of Meteosat-7 AMVs over this region. To demonstrate its initial application, INSAT-3D AMVs are assimilated in the Weather Research and Forecasting (WRF) model and it is found that the assimilation of newly derived AMVs has helped in reduction of track forecast errors of the recent cyclonic storm NANAUK over the Arabian Sea. Though, the present study is limited to its application to one case study, however, it will provide some guidance to the operational agencies for implementation of this new AMV dataset for future applications in the Numerical Weather Prediction (NWP) over the south Asia region.

  17. SU-E-J-238: Monitoring Lymph Node Volumes During Radiotherapy Using Semi-Automatic Segmentation of MRI Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veeraraghavan, H; Tyagi, N; Riaz, N

    2014-06-01

    Purpose: Identification and image-based monitoring of lymph nodes growing due to disease, could be an attractive alternative to prophylactic head and neck irradiation. We evaluated the accuracy of the user-interactive Grow Cut algorithm for volumetric segmentation of radiotherapy relevant lymph nodes from MRI taken weekly during radiotherapy. Method: The algorithm employs user drawn strokes in the image to volumetrically segment multiple structures of interest. We used a 3D T2-wturbo spin echo images with an isotropic resolution of 1 mm3 and FOV of 492×492×300 mm3 of head and neck cancer patients who underwent weekly MR imaging during the course of radiotherapy.more » Various lymph node (LN) levels (N2, N3, N4'5) were individually contoured on the weekly MR images by an expert physician and used as ground truth in our study. The segmentation results were compared with the physician drawn lymph nodes based on DICE similarity score. Results: Three head and neck patients with 6 weekly MR images were evaluated. Two patients had level 2 LN drawn and one patient had level N2, N3 and N4'5 drawn on each MR image. The algorithm took an average of a minute to segment the entire volume (512×512×300 mm3). The algorithm achieved an overall DICE similarity score of 0.78. The time taken for initializing and obtaining the volumetric mask was about 5 mins for cases with only N2 LN and about 15 mins for the case with N2,N3 and N4'5 level nodes. The longer initialization time for the latter case was due to the need for accurate user inputs to separate overlapping portions of the different LN. The standard deviation in segmentation accuracy at different time points was utmost 0.05. Conclusions: Our initial evaluation of the grow cut segmentation shows reasonably accurate and consistent volumetric segmentations of LN with minimal user effort and time.« less

  18. High-resolution MRI vessel wall imaging: spatial and temporal patterns of reversible cerebral vasoconstriction syndrome and central nervous system vasculitis.

    PubMed

    Obusez, E C; Hui, F; Hajj-Ali, R A; Cerejo, R; Calabrese, L H; Hammad, T; Jones, S E

    2014-08-01

    High-resolution MR imaging is an emerging tool for evaluating intracranial artery disease. It has an advantage of defining vessel wall characteristics of intracranial vascular diseases. We investigated high-resolution MR imaging arterial wall characteristics of CNS vasculitis and reversible cerebral vasoconstriction syndrome to determine wall pattern changes during a follow-up period. We retrospectively reviewed 3T-high-resolution MR imaging vessel wall studies performed on 26 patients with a confirmed diagnosis of CNS vasculitis and reversible cerebral vasoconstriction syndrome during a follow-up period. Vessel wall imaging protocol included black-blood contrast-enhanced T1-weighted sequences with fat suppression and a saturation band, and time-of-flight MRA of the circle of Willis. Vessel wall characteristics including enhancement, wall thickening, and lumen narrowing were collected. Thirteen patients with CNS vasculitis and 13 patients with reversible cerebral vasoconstriction syndrome were included. In the CNS vasculitis group, 9 patients showed smooth, concentric wall enhancement and thickening; 3 patients had smooth, eccentric wall enhancement and thickening; and 1 patient was without wall enhancement and thickening. Six of 13 patients had follow-up imaging; 4 patients showed stable smooth, concentric enhancement and thickening; and 2 patients had resoluton of initial imaging findings. In the reversible cerebral vasoconstriction syndrome group, 10 patients showed diffuse, uniform wall thickening with negligible-to-mild enhancement. Nine patients had follow-up imaging, with 8 patients showing complete resolution of the initial findings. Postgadolinium 3T-high-resolution MR imaging appears to be a feasible tool in differentiating vessel wall patterns of CNS vasculitis and reversible cerebral vasoconstriction syndrome changes during a follow-up period. © 2014 by American Journal of Neuroradiology.

  19. New approaches for measuring changes in the cortical surface using an automatic reconstruction algorithm

    NASA Astrophysics Data System (ADS)

    Pham, Dzung L.; Han, Xiao; Rettmann, Maryam E.; Xu, Chenyang; Tosun, Duygu; Resnick, Susan; Prince, Jerry L.

    2002-05-01

    In previous work, the authors presented a multi-stage procedure for the semi-automatic reconstruction of the cerebral cortex from magnetic resonance images. This method suffered from several disadvantages. First, the tissue classification algorithm used can be sensitive to noise within the image. Second, manual interaction was required for masking out undesired regions of the brain image, such as the ventricles and putamen. Third, iterated median filters were used to perform a topology correction on the initial cortical surface, resulting in an overly smoothed initial surface. Finally, the deformable surface used to converge to the cortex had difficulty capturing narrow gyri. In this work, all four disadvantages of the procedure have been addressed. A more robust tissue classification algorithm is employed and the manual masking step is replaced by an automatic method involving level set deformable models. Instead of iterated median filters, an algorithm developed specifically for topology correction is used. The last disadvantage is addressed using an algorithm that artificially separates adjacent sulcal banks. The new procedure is more automated but also more accurate than the previous one. Its utility is demonstrated by performing a preliminary study on data from the Baltimore Longitudinal Study of Aging.

  20. Affective learning in adults with intellectual disability: an experiment using evaluative conditioning.

    PubMed

    Blanchette, I; Treillet, V; Davies, S R

    2016-03-01

    Evaluative conditioning is a form of affective learning in which initially neutral stimuli acquire an affective value through association with negative or positive stimuli. Recent research shows an important role for cognitive resources in this type of learning. This form of affective learning has rarely been studied in intellectual disability (ID). We examined evaluative conditioning in 16 adults with mild to moderate ID compared to age- and gender-matched control participants. Neutral shapes and symbols were repeatedly paired with positive, neutral or negative unconditioned stimuli (faces or International Affective Picture System images). There was also an extinction phase. There was significant acquisition of conditioning in both groups. Stimuli paired with positive images were evaluated more positively, and stimuli paired with negative images were evaluated more negatively. Post-extinction ratings however show that these novel affective associations were not maintained by individuals with ID as much as by individuals in the control group. We conclude that ID modulates some aspects of affective learning but not necessarily initial preference acquisition. © 2015 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd.

  1. Are pre-treatment psychological characteristics influenced by pre-surgical orthodontics?

    PubMed

    Cunningham, S J; Gilthorpe, M S; Hunt, N P

    2001-12-01

    A number of investigations have looked at psychological changes occurring in association with orthognathic treatment. However, most of these studies have used a pre-surgery questionnaire as the baseline measurement. There is little data relating to the true baseline, i.e. that prior to any active treatment. Until this aspect is investigated, it is not possible to assume that pre-surgery is an acceptable baseline. This questionnaire based study aimed to assess changes in six psychological outcome measures between T1 (prior to any active treatment) and T2 (following pre-surgical orthodontics/prior to surgery). The outcome variables were: state anxiety, trait anxiety, depression, self-esteem, body image, and facial body image. Sixty-two patients (39 females and 23 males) completed both questionnaires. The results showed that intervention, in the form of orthodontic treatment, had a minimal effect on the chosen psychometric outcome variables. There was a significant reduction in satisfaction with body image amongst patients who initially reported mild to moderate dental/facial problems, whilst a moderate increase in satisfaction occurred in those patients reporting severe conditions initially. Also of note were significant increases in state anxiety amongst older patients whilst trait anxiety showed greater increases in females than males.

  2. Chronic Use of Aspirin and Total White Matter Lesion Volume: Results from the Women's Health Initiative Memory Study of Magnetic Resonance Imaging Study.

    PubMed

    Holcombe, Andrea; Ammann, Eric; Espeland, Mark A; Kelley, Brendan J; Manson, JoAnn E; Wallace, Robert; Robinson, Jennifer

    2017-10-01

    To investigate the relationship between aspirin and subclinical cerebrovascular heath, we evaluated the effect of chronic aspirin use on white matter lesions (WML) volume among women. Chronic aspirin use was assessed in 1365 women who participated in the Women's Health Initiative Memory Study of Magnetic Resonance Imaging. Differences in WML volumes between aspirin users and nonusers were assessed with linear mixed models. A number of secondary analyses were performed, including lobe-specific analyses, subgroup analyses based on participants' overall risk of cerebrovascular disease, and a dose-response relationship analysis. The mean age of the women at magnetic resonance imaging examination was 77.6 years. Sixty-one percent of participants were chronic aspirin users. After adjusting for demographic variables and comorbidities, chronic aspirin use was nonsignificantly associated with 4.8% (95% CI: -6.8%, 17.9%) larger WML volumes. These null findings were confirmed in secondary and sensitivity analyses, including an active comparator evaluation where aspirin users were compared to users of nonaspirin nonsteroidal anti-inflammatory drugs or acetaminophen. There was a nonsignificant difference in WML volumes between aspirin users and nonusers. Further, our results suggest that chronic aspirin use may not have a clinically significant effect on WML volumes in women. Published by Elsevier Inc.

  3. Advanced two-layer level set with a soft distance constraint for dual surfaces segmentation in medical images

    NASA Astrophysics Data System (ADS)

    Ji, Yuanbo; van der Geest, Rob J.; Nazarian, Saman; Lelieveldt, Boudewijn P. F.; Tao, Qian

    2018-03-01

    Anatomical objects in medical images very often have dual contours or surfaces that are highly correlated. Manually segmenting both of them by following local image details is tedious and subjective. In this study, we proposed a two-layer region-based level set method with a soft distance constraint, which not only regularizes the level set evolution at two levels, but also imposes prior information on wall thickness in an effective manner. By updating the level set function and distance constraint functions alternatingly, the method simultaneously optimizes both contours while regularizing their distance. The method was applied to segment the inner and outer wall of both left atrium (LA) and left ventricle (LV) from MR images, using a rough initialization from inside the blood pool. Compared to manual annotation from experience observers, the proposed method achieved an average perpendicular distance (APD) of less than 1mm for the LA segmentation, and less than 1.5mm for the LV segmentation, at both inner and outer contours. The method can be used as a practical tool for fast and accurate dual wall annotations given proper initialization.

  4. Navigation surgery using an augmented reality for pancreatectomy.

    PubMed

    Okamoto, Tomoyoshi; Onda, Shinji; Yasuda, Jungo; Yanaga, Katsuhiko; Suzuki, Naoki; Hattori, Asaki

    2015-01-01

    The aim of this study was to evaluate the utility of navigation surgery using augmented reality technology (AR-based NS) for pancreatectomy. The 3D reconstructed images from CT were created by segmentation. The initial registration was performed by using the optical location sensor. The reconstructed images were superimposed onto the real organs in the monitor display. Of the 19 patients who had undergone hepatobiliary and pancreatic surgery using AR-based NS, the accuracy, visualization ability, and utility of our system were assessed in five cases with pancreatectomy. The position of each organ in the surface-rendering image corresponded almost to that of the actual organ. Reference to the display image allowed for safe dissection while preserving the adjacent vessels or organs. The locations of the lesions and resection line on the targeted organ were overlaid on the operating field. The initial mean registration error was improved to approximately 5 mm by our refinements. However, several problems such as registration accuracy, portability and cost still remain. AR-based NS contributed to accurate and effective surgical resection in pancreatectomy. The pancreas appears to be a suitable organ for further investigations. This technology is promising to improve surgical quality, training, and education. © 2015 S. Karger AG, Basel.

  5. Safe discharge and outpatient investigation of ureteric colic: a retrospective analysis.

    PubMed

    Stewart, Michael

    2017-07-12

    Computed tomography of the kidneys, ureters and bladder is the recommended imaging modality for suspected urolithiasis. Early scanning is advised in guidelines, but there is limited published evidence to support this recommendation. In a retrospective study, we reviewed patients managed according to a local guideline. Patients without high-risk features were either imaged during their initial visit (if in the daytime) or discharged for outpatient scans. Complications, unplanned returns, final diagnosis, and intervention rates were compared between groups. Fifty-four patients were scanned during their initial visit and 151 were scanned as an outpatient at a median interval of 10 days. Unplanned return rates were lower in those scanned as outpatients (7.3 vs. 24.1%), with no significant difference in complications (2.0 vs. 3.7%; none leading to permanent harm). Those scanned as outpatients were less likely to have a stone proven by imaging (39.7 vs. 64.8%), but did not have a significantly higher rate of proven alternative diagnosis (9.3 vs. 13.0%). There is no evidence in this cohort that discharging patients for outpatient imaging is associated with poorer outcomes, provided that an appropriate clinical risk assessment is carried out.

  6. Radiolabelled D2 agonists as prolactinoma imaging agents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Otto, C.A.

    1991-12-31

    Research conducted in this terminal year of support centered on three distinct areas: mAChR ligand localization in pancreas and the effect of Ca{sup +2} on localization, continuation of assessment of quaternized and neutral mAChR ligands for possible use as PET myocardial imaging agents, and initiation of a study to determine the relationship of the nAChR receptor to the cellular receptor for measles virus. Several tables and figures illustrating the results are included.

  7. A Content Analysis of Television Ads: Does Current Practice Maximize Cognitive Processing?

    DTIC Science & Technology

    2008-12-11

    ads with arousing content such as sexual imagery and fatty/sweet food imagery have the potential to stress the cognitive processing system. When the...to examine differences in content arousal , this study included variables shown to elicit arousal —loved brands, sexual images, and fatty/sweet food...loved brands as well as ads with sexual and fatty/food images are not all the same—they are not likely to be equally arousing . Initially, brands were

  8. Applying image quality in cell phone cameras: lens distortion

    NASA Astrophysics Data System (ADS)

    Baxter, Donald; Goma, Sergio R.; Aleksic, Milivoje

    2009-01-01

    This paper describes the framework used in one of the pilot studies run under the I3A CPIQ initiative to quantify overall image quality in cell-phone cameras. The framework is based on a multivariate formalism which tries to predict overall image quality from individual image quality attributes and was validated in a CPIQ pilot program. The pilot study focuses on image quality distortions introduced in the optical path of a cell-phone camera, which may or may not be corrected in the image processing path. The assumption is that the captured image used is JPEG compressed and the cellphone camera is set to 'auto' mode. As the used framework requires that the individual attributes to be relatively perceptually orthogonal, in the pilot study, the attributes used are lens geometric distortion (LGD) and lateral chromatic aberrations (LCA). The goal of this paper is to present the framework of this pilot project starting with the definition of the individual attributes, up to their quantification in JNDs of quality, a requirement of the multivariate formalism, therefore both objective and subjective evaluations were used. A major distinction in the objective part from the 'DSC imaging world' is that the LCA/LGD distortions found in cell-phone cameras, rarely exhibit radial behavior, therefore a radial mapping/modeling cannot be used in this case.

  9. Cardiac-gated parametric images from 82 Rb PET from dynamic frames and direct 4D reconstruction.

    PubMed

    Germino, Mary; Carson, Richard E

    2018-02-01

    Cardiac perfusion PET data can be reconstructed as a dynamic sequence and kinetic modeling performed to quantify myocardial blood flow, or reconstructed as static gated images to quantify function. Parametric images from dynamic PET are conventionally not gated, to allow use of all events with lower noise. An alternative method for dynamic PET is to incorporate the kinetic model into the reconstruction algorithm itself, bypassing the generation of a time series of emission images and directly producing parametric images. So-called "direct reconstruction" can produce parametric images with lower noise than the conventional method because the noise distribution is more easily modeled in projection space than in image space. In this work, we develop direct reconstruction of cardiac-gated parametric images for 82 Rb PET with an extension of the Parametric Motion compensation OSEM List mode Algorithm for Resolution-recovery reconstruction for the one tissue model (PMOLAR-1T). PMOLAR-1T was extended to accommodate model terms to account for spillover from the left and right ventricles into the myocardium. The algorithm was evaluated on a 4D simulated 82 Rb dataset, including a perfusion defect, as well as a human 82 Rb list mode acquisition. The simulated list mode was subsampled into replicates, each with counts comparable to one gate of a gated acquisition. Parametric images were produced by the indirect (separate reconstructions and modeling) and direct methods for each of eight low-count and eight normal-count replicates of the simulated data, and each of eight cardiac gates for the human data. For the direct method, two initialization schemes were tested: uniform initialization, and initialization with the filtered iteration 1 result of the indirect method. For the human dataset, event-by-event respiratory motion compensation was included. The indirect and direct methods were compared for the simulated dataset in terms of bias and coefficient of variation as a function of iteration. Convergence of direct reconstruction was slow with uniform initialization; lower bias was achieved in fewer iterations by initializing with the filtered indirect iteration 1 images. For most parameters and regions evaluated, the direct method achieved the same or lower absolute bias at matched iteration as the indirect method, with 23%-65% lower noise. Additionally, the direct method gave better contrast between the perfusion defect and surrounding normal tissue than the indirect method. Gated parametric images from the human dataset had comparable relative performance of indirect and direct, in terms of mean parameter values per iteration. Changes in myocardial wall thickness and blood pool size across gates were readily visible in the gated parametric images, with higher contrast between myocardium and left ventricle blood pool in parametric images than gated SUV images. Direct reconstruction can produce parametric images with less noise than the indirect method, opening the potential utility of gated parametric imaging for perfusion PET. © 2017 American Association of Physicists in Medicine.

  10. Microscopic vision modeling method by direct mapping analysis for micro-gripping system with stereo light microscope.

    PubMed

    Wang, Yuezong; Zhao, Zhizhong; Wang, Junshuai

    2016-04-01

    We present a novel and high-precision microscopic vision modeling method, which can be used for 3D data reconstruction in micro-gripping system with stereo light microscope. This method consists of four parts: image distortion correction, disparity distortion correction, initial vision model and residual compensation model. First, the method of image distortion correction is proposed. Image data required by image distortion correction comes from stereo images of calibration sample. The geometric features of image distortions can be predicted though the shape deformation of lines constructed by grid points in stereo images. Linear and polynomial fitting methods are applied to correct image distortions. Second, shape deformation features of disparity distribution are discussed. The method of disparity distortion correction is proposed. Polynomial fitting method is applied to correct disparity distortion. Third, a microscopic vision model is derived, which consists of two models, i.e., initial vision model and residual compensation model. We derive initial vision model by the analysis of direct mapping relationship between object and image points. Residual compensation model is derived based on the residual analysis of initial vision model. The results show that with maximum reconstruction distance of 4.1mm in X direction, 2.9mm in Y direction and 2.25mm in Z direction, our model achieves a precision of 0.01mm in X and Y directions and 0.015mm in Z direction. Comparison of our model with traditional pinhole camera model shows that two kinds of models have a similar reconstruction precision of X coordinates. However, traditional pinhole camera model has a lower precision of Y and Z coordinates than our model. The method proposed in this paper is very helpful for the micro-gripping system based on SLM microscopic vision. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Neutron Imaging for Selective Laser Melting Inconel Hardware with Internal Passages

    NASA Technical Reports Server (NTRS)

    Tramel, Terri L.; Norwood, Joseph K.; Bilheux, Hassina

    2014-01-01

    Additive Manufacturing is showing great promise for the development of new innovative designs and large potential life cycle cost reduction for the Aerospace Industry. However, more development work is required to move this technology into space flight hardware production. With selective laser melting (SLM), hardware that once consisted of multiple, carefully machined and inspected pieces, joined together can be made in one part. However standard inspection techniques cannot be used to verify that the internal passages are within dimensional tolerances or surface finish requirements. NASA/MSFC traveled to Oak Ridge National Lab's (ORNL) Spallation Neutron Source to perform some non-destructive, proof of concept imaging measurements to assess the capabilities to understand internal dimensional tolerances and internal passages surface roughness. This presentation will describe 1) the goals of this proof of concept testing, 2) the lessons learned when designing and building these Inconel 718 test specimens to minimize beam time, 3) the neutron imaging test setup and test procedure to get the images, 4) the initial results in images, volume and a video, 4) the assessment of using this imaging technique to gather real data for designing internal flow passages in SLM manufacturing aerospace hardware, and lastly 5) how proper cleaning of the internal passages is critically important. In summary, the initial results are very promising and continued development of a technique to assist in SLM development for aerospace components is desired by both NASA and ORNL. A plan forward that benefits both ORNL and NASA will also be presented, based on the promising initial results. The initial images and volume reconstruction showed that clean, clear images of the internal passages geometry are obtainable. These clear images of the internal passages of simple geometries will be compared to the build model to determine any differences. One surprising result was that a new cleaning process was used on these simply geometric specimens that resulted in what appears to be very smooth internal surfaces, when compared to other aerospace hardware cleaning methods.

  12. The algorithm of motion blur image restoration based on PSF half-blind estimation

    NASA Astrophysics Data System (ADS)

    Chen, Da-Ke; Lin, Zhe

    2011-08-01

    A novel algorithm of motion blur image restoration based on PSF half-blind estimation with Hough transform was introduced on the basis of full analysis of the principle of TDICCD camera, with the problem that vertical uniform linear motion estimation used by IBD algorithm as the original value of PSF led to image restoration distortion. Firstly, the mathematical model of image degradation was established with the transcendental information of multi-frame images, and then two parameters (movement blur length and angle) that have crucial influence on PSF estimation was set accordingly. Finally, the ultimate restored image can be acquired through multiple iterative of the initial value of PSF estimation in Fourier domain, which the initial value was gained by the above method. Experimental results show that the proposal algorithm can not only effectively solve the image distortion problem caused by relative motion between TDICCD camera and movement objects, but also the details characteristics of original image are clearly restored.

  13. VPAC1-targeted PET/CT scan: improved molecular imaging for the diagnosis of prostate cancer using a novel cell surface antigen.

    PubMed

    Truong, Hong; Gomella, Leonard G; Thakur, Mathew L; Trabulsi, Edouard J

    2018-05-01

    Current approaches to prostate cancer screening and diagnosis are plagued with limitations in diagnostic accuracy. There is a compelling need for biomolecular imaging that will not only detect prostate cancer early but also distinguish prostate cancer from benign lesions accurately. In this topic paper, we review evidence that supports further investigation of VPAC1-targeted PET/CT imaging in the primary diagnosis of prostate cancer. A non-systematic review of Medline/PubMed was performed. English language guidelines on prostate cancer diagnosis and management, original articles, and review articles were selected based on their clinical relevance. VPAC1 receptors were overexpressed 1000 times more in prostate cancer than benign prostatic stromal tissue. In vitro and in vivo studies showed that Copper-64 labeled analogs of VPAC1 ligands can be synthesized with high radiochemical efficiency and purity. The radioactive probes had excellent VPAC1 receptor binding specificity and affinity. They had good biochemical stability in vitro and in mouse and human serum. They had minimal urinary excretion, which made them favorable for prostate cancer imaging. Initial feasibility study in men with prostate cancer showed that the probes were safe with no reported adverse reaction. 64 Cu-TP3805 PET/CT detected 98% of prostate cancer lesions and nodal metastasis as confirmed with whole mount histopathological evaluation. VPAC1 receptors are promising targets for biomolecular imaging of primary prostate cancer that can distinguish malignant from benign lesions non-invasively. Further investigations are warranted to validate initial findings and define the clinical utilities of VPAC1-targeted PET imaging for prostate cancer diagnosis and management.

  14. Comparative studies of brain activation with MEG and functional MRI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George, J.S.; Aine, C.J.; Sanders, J.A.

    The past two years have witnessed the emergence of MRI as a functional imaging methodology. Initial demonstrations involved the injection of a paramagnetic contrast agent and required ultrafast echo planar imaging capability to adequately resolve the passage of the injected bolus. By measuring the local reduction in image intensity due to magnetic susceptibility, it was possible to calculate blood volume, which changes as a function of neural activation. Later developments have exploited endogenous contrast mechanisms to monitor changes in blood volume or in venous blood oxygen content. Recently, we and others have demonstrated that it is possible to make suchmore » measurements in a clinical imager, suggesting that the large installed base of such machines might be utilized for functional imaging. Although it is likely that functional MRI (fMRI) will subsume some of the clinical and basic neuroscience applications now touted for MEG, it is also clear that these techniques offer different largely complementary, capabilities. At the very least, it is useful to compare and cross-validate the activation maps produced by these techniques. Such studies will be valuable as a check on results of neuromagnetic distributed current reconstructions and will allow better characterization of the relationship between neurophysiological activation and associated hemodynamic changes. A more exciting prospect is the development of analyses that combine information from the two modalities to produce a better description of underlying neural activity than is possible with either technique in isolation. In this paper we describe some results from initial comparative studies and outline several techniques that can be used to treat MEG and fMRI data within a unified computational framework.« less

  15. Evidence based diagnosis and management of chronic subdural hematoma: A review of the literature.

    PubMed

    Mehta, Vikram; Harward, Stephen C; Sankey, Eric W; Nayar, Gautam; Codd, Patrick J

    2018-04-01

    Chronic subdural hematomas are encapsulated blood collections within the dural border cells with characteristic outer "neomembranes". Affected patients are more often male and typically above the age of 70. Imaging shows crescentic layering of fluid in the subdural space on a non-contrast computed tomography (CT) scan, best appreciated on sagittal or coronal reformats. Initial medical management involves reversing anticoagulant/antiplatelet therapies, and often initiation of anti-epileptic drugs (AEDs). Operative interventions, such as twist-drill craniostomy (TDC), burr-hole craniostomy (BHC), and craniotomy are indicated if imaging implies compression (maximum fluid collection thickness >1 cm) or the patient is symptomatic. The effectiveness of various surgical techniques remains poorly characterized, with sparse level 1 evidence, variable outcome measures, and various surgical techniques. Postoperatively, subdural drains can decrease recurrence and sequential compression devices can decrease embolic complications, while measures such as early mobilization and re-initiation of anticoagulation need further study. Non-operative management, including steroid therapy, etizolam, tranexamic acid, and angiotensin converting enzyme inhibitors (ACEI) also remain poorly studied. Recurrent hemorrhages are a major complication affecting around 10-20% of patients, and therefore close follow-up is essential. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Early time studies of cylindrical liner implosions at 1 MA on COBRA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atoyan, L., E-mail: la296@cornell.edu; Byvank, T., E-mail: la296@cornell.edu; Cahill, A. D., E-mail: la296@cornell.edu

    Tests of the magnetized liner inertial fusion (MagLIF) concept will make use of the 27 MA Z machine at Sandia National Laboratories, Albuquerque, to implode a cylindrical metal liner to compress and heat preheated, magnetized plasma contained within it. While most pulsed power machines produce much lower currents than the Z-machine, there are issues that can still be addressed on smaller scale facilities. Recent work on the Cornell Beam Research Accelerator (COBRA) has made use of 10 mm long and 4 mm diameter metal liners having different wall thicknesses to study the initiation of plasma on the liner’s surface asmore » well as axial magnetic field compression [P.-A. Gourdain et al., Nucl. Fusion 53, 083006 (2013)]. This report presents experimental results with non-imploding liners, investigating the impact the liner’s surface structure has on initiation and ablation. Extreme ultraviolet (XUV) imaging and optical 12 frame camera imaging were used to observe and assess emission non-uniformities as they developed. Axial and side-on interferometry was used to determine the distribution of plasma near the liner surface, including the impact of non-uniformities during the plasma initiation and ablation phases of the experiments.« less

  17. Early time studies of cylindrical liner implosions at 1 MA on COBRA

    NASA Astrophysics Data System (ADS)

    Atoyan, L.; Byvank, T.; Cahill, A. D.; Hoyt, C. L.; de Grouchy, P. W. L.; Potter, W. M.; Kusse, B. R.; Hammer, D. A.

    2014-12-01

    Tests of the magnetized liner inertial fusion (MagLIF) concept will make use of the 27 MA Z machine at Sandia National Laboratories, Albuquerque, to implode a cylindrical metal liner to compress and heat preheated, magnetized plasma contained within it. While most pulsed power machines produce much lower currents than the Z-machine, there are issues that can still be addressed on smaller scale facilities. Recent work on the Cornell Beam Research Accelerator (COBRA) has made use of 10 mm long and 4 mm diameter metal liners having different wall thicknesses to study the initiation of plasma on the liner's surface as well as axial magnetic field compression [P.-A. Gourdain et al., Nucl. Fusion 53, 083006 (2013)]. This report presents experimental results with non-imploding liners, investigating the impact the liner's surface structure has on initiation and ablation. Extreme ultraviolet (XUV) imaging and optical 12 frame camera imaging were used to observe and assess emission non-uniformities as they developed. Axial and side-on interferometry was used to determine the distribution of plasma near the liner surface, including the impact of non-uniformities during the plasma initiation and ablation phases of the experiments.

  18. New learning based super-resolution: use of DWT and IGMRF prior.

    PubMed

    Gajjar, Prakash P; Joshi, Manjunath V

    2010-05-01

    In this paper, we propose a new learning-based approach for super-resolving an image captured at low spatial resolution. Given the low spatial resolution test image and a database consisting of low and high spatial resolution images, we obtain super-resolution for the test image. We first obtain an initial high-resolution (HR) estimate by learning the high-frequency details from the available database. A new discrete wavelet transform (DWT) based approach is proposed for learning that uses a set of low-resolution (LR) images and their corresponding HR versions. Since the super-resolution is an ill-posed problem, we obtain the final solution using a regularization framework. The LR image is modeled as the aliased and noisy version of the corresponding HR image, and the aliasing matrix entries are estimated using the test image and the initial HR estimate. The prior model for the super-resolved image is chosen as an Inhomogeneous Gaussian Markov random field (IGMRF) and the model parameters are estimated using the same initial HR estimate. A maximum a posteriori (MAP) estimation is used to arrive at the cost function which is minimized using a simple gradient descent approach. We demonstrate the effectiveness of the proposed approach by conducting the experiments on gray scale as well as on color images. The method is compared with the standard interpolation technique and also with existing learning-based approaches. The proposed approach can be used in applications such as wildlife sensor networks, remote surveillance where the memory, the transmission bandwidth, and the camera cost are the main constraints.

  19. Baseline antenna design for space exploration initiative

    NASA Technical Reports Server (NTRS)

    Chen, Y. L.; Nasir, M. A.; Lee, S. W.; Zaman, Afroz

    1993-01-01

    A key element of the future NASA Space Exploration Initiative (SEI) mission is the lunar and Mars telecommunication system. This system will provide voice, image, and data transmission to monitor unmanned missions to conduct experiments, and to provide radiometric data for navigation. In the later half of 1991, a study was conducted on antennas for the Mars Exploration Communication. Six antenna configurations were examined: three reflector and three phased array. The conclusion was that due to wide-angle scan requirement, and multiple simultaneous tracking beams, phased arrays are more suitable. For most part, this report studies phased array antenna designs for two different applications for Space Exploration Initiative. It also studies one design for a tri-reflector type antenna. These antennas will be based on a Mars orbiting satellite.

  20. Automatic image fusion of real-time ultrasound with computed tomography images: a prospective comparison between two auto-registration methods.

    PubMed

    Cha, Dong Ik; Lee, Min Woo; Kim, Ah Yeong; Kang, Tae Wook; Oh, Young-Taek; Jeong, Ja-Yeon; Chang, Jung-Woo; Ryu, Jiwon; Lee, Kyong Joon; Kim, Jaeil; Bang, Won-Chul; Shin, Dong Kuk; Choi, Sung Jin; Koh, Dalkwon; Seo, Bong Koo; Kim, Kyunga

    2017-11-01

    Background A major drawback of conventional manual image fusion is that the process may be complex, especially for less-experienced operators. Recently, two automatic image fusion techniques called Positioning and Sweeping auto-registration have been developed. Purpose To compare the accuracy and required time for image fusion of real-time ultrasonography (US) and computed tomography (CT) images between Positioning and Sweeping auto-registration. Material and Methods Eighteen consecutive patients referred for planning US for radiofrequency ablation or biopsy for focal hepatic lesions were enrolled. Image fusion using both auto-registration methods was performed for each patient. Registration error, time required for image fusion, and number of point locks used were compared using the Wilcoxon signed rank test. Results Image fusion was successful in all patients. Positioning auto-registration was significantly faster than Sweeping auto-registration for both initial (median, 11 s [range, 3-16 s] vs. 32 s [range, 21-38 s]; P < 0.001] and complete (median, 34.0 s [range, 26-66 s] vs. 47.5 s [range, 32-90]; P = 0.001] image fusion. Registration error of Positioning auto-registration was significantly higher for initial image fusion (median, 38.8 mm [range, 16.0-84.6 mm] vs. 18.2 mm [6.7-73.4 mm]; P = 0.029), but not for complete image fusion (median, 4.75 mm [range, 1.7-9.9 mm] vs. 5.8 mm [range, 2.0-13.0 mm]; P = 0.338]. Number of point locks required to refine the initially fused images was significantly higher with Positioning auto-registration (median, 2 [range, 2-3] vs. 1 [range, 1-2]; P = 0.012]. Conclusion Positioning auto-registration offers faster image fusion between real-time US and pre-procedural CT images than Sweeping auto-registration. The final registration error is similar between the two methods.

  1. TheHiveDB image data management and analysis framework.

    PubMed

    Muehlboeck, J-Sebastian; Westman, Eric; Simmons, Andrew

    2014-01-06

    The hive database system (theHiveDB) is a web-based brain imaging database, collaboration, and activity system which has been designed as an imaging workflow management system capable of handling cross-sectional and longitudinal multi-center studies. It can be used to organize and integrate existing data from heterogeneous projects as well as data from ongoing studies. It has been conceived to guide and assist the researcher throughout the entire research process, integrating all relevant types of data across modalities (e.g., brain imaging, clinical, and genetic data). TheHiveDB is a modern activity and resource management system capable of scheduling image processing on both private compute resources and the cloud. The activity component supports common image archival and management tasks as well as established pipeline processing (e.g., Freesurfer for extraction of scalar measures from magnetic resonance images). Furthermore, via theHiveDB activity system algorithm developers may grant access to virtual machines hosting versioned releases of their tools to collaborators and the imaging community. The application of theHiveDB is illustrated with a brief use case based on organizing, processing, and analyzing data from the publically available Alzheimer Disease Neuroimaging Initiative.

  2. TheHiveDB image data management and analysis framework

    PubMed Central

    Muehlboeck, J-Sebastian; Westman, Eric; Simmons, Andrew

    2014-01-01

    The hive database system (theHiveDB) is a web-based brain imaging database, collaboration, and activity system which has been designed as an imaging workflow management system capable of handling cross-sectional and longitudinal multi-center studies. It can be used to organize and integrate existing data from heterogeneous projects as well as data from ongoing studies. It has been conceived to guide and assist the researcher throughout the entire research process, integrating all relevant types of data across modalities (e.g., brain imaging, clinical, and genetic data). TheHiveDB is a modern activity and resource management system capable of scheduling image processing on both private compute resources and the cloud. The activity component supports common image archival and management tasks as well as established pipeline processing (e.g., Freesurfer for extraction of scalar measures from magnetic resonance images). Furthermore, via theHiveDB activity system algorithm developers may grant access to virtual machines hosting versioned releases of their tools to collaborators and the imaging community. The application of theHiveDB is illustrated with a brief use case based on organizing, processing, and analyzing data from the publically available Alzheimer Disease Neuroimaging Initiative. PMID:24432000

  3. Ultra-Wide Field Imaging in Paradoxical Worsening of Tubercular Multifocal Serpiginoid Choroiditis after the Initiation of Anti-Tubercular Therapy.

    PubMed

    Aggarwal, Kanika; Agarwal, Aniruddha; Deokar, Ankit; Singh, Ramandeep; Bansal, Reema; Sharma, Aman; Sharma, Kusum; Dogra, Mangat R; Gupta, Vishali

    2017-10-11

    To evaluate role of ultra-wide field (UWF) versus conventional imaging in the follow-up and paradoxical worsening (PW) of tubercular (TB) multifocal serpiginoid choroiditis (MSC). Prospective observational study of patients with TB MSC undergoing UWF imaging, autofluorescence and fluorescein angiography was performed. A circle simulating central 75° field representing conventional imaging was drawn on UWF images. The information yielded by the two modalities, progression of choroiditis lesions and PW was compared. 44 eyes (29 patients, mean age: 30.7 ± 9 years; 23 males) were included. UWF imaging showed additional lesions in 39/44 eyes (88.6%). Overall, 16/44 eyes (36.4%) showed PW; 3/16 eyes (18.7%) showed only peripheral PW, while 10/16 eyes showed both central and peripheral PW. Management was altered in 11 patients (37.93%) based on UWF imaging. UWF is more useful than conventional imaging in identifying additional choroiditis lesions, PW and altering the course of therapy in TB MSC.

  4. In vivo 3D PIXE-micron-CT imaging of Drosophila melanogaster using a contrast agent

    NASA Astrophysics Data System (ADS)

    Matsuyama, Shigeo; Hamada, Naoki; Ishii, Keizo; Nozawa, Yuichiro; Ohkura, Satoru; Terakawa, Atsuki; Hatori, Yoshinobu; Fujiki, Kota; Fujiwara, Mitsuhiro; Toyama, Sho

    2015-04-01

    In this study, we developed a three-dimensional (3D) computed tomography (CT) in vivo imaging system for imaging small insects with micrometer resolution. The 3D CT imaging system, referred to as 3D PIXE-micron-CT (PIXEμCT), uses characteristic X-rays produced by ion microbeam bombardment of a metal target. PIXEμCT was used to observe the body organs and internal structure of a living Drosophila melanogaster. Although the organs of the thorax were clearly imaged, the digestive organs in the abdominal cavity could not be clearly discerned initially, with the exception of the rectum and the Malpighian tubule. To enhance the abdominal images, a barium sulfate powder radiocontrast agent was added. For the first time, 3D images of the ventriculus of a living D. melanogaster were obtained. Our results showed that PIXEμCT can provide in vivo 3D-CT images that reflect correctly the structure of individual living organs, which is expected to be very useful in biological research.

  5. [Development of an original computer program FISHMet: use for molecular cytogenetic diagnosis and genome mapping by fluorescent in situ hybridization (FISH)].

    PubMed

    Iurov, Iu B; Khazatskiĭ, I A; Akindinov, V A; Dovgilov, L V; Kobrinskiĭ, B A; Vorsanova, S G

    2000-08-01

    Original software FISHMet has been developed and tried for improving the efficiency of diagnosis of hereditary diseases caused by chromosome aberrations and for chromosome mapping by fluorescent in situ hybridization (FISH) method. The program allows creation and analysis of pseudocolor chromosome images and hybridization signals in the Windows 95 system, allows computer analysis and editing of the results of pseudocolor hybridization in situ, including successive imposition of initial black-and-white images created using fluorescent filters (blue, green, and red), and editing of each image individually or of a summary pseudocolor image in BMP, TIFF, and JPEG formats. Components of image computer analysis system (LOMO, Leitz Ortoplan, and Axioplan fluorescent microscopes, COHU 4910 and Sanyo VCB-3512P CCD cameras, Miro-Video, Scion LG-3 and VG-5 image capture maps, and Pentium 100 and Pentium 200 computers) and specialized software for image capture and visualization (Scion Image PC and Video-Cup) have been used with good results in the study.

  6. 3D Filament Network Segmentation with Multiple Active Contours

    NASA Astrophysics Data System (ADS)

    Xu, Ting; Vavylonis, Dimitrios; Huang, Xiaolei

    2014-03-01

    Fluorescence microscopy is frequently used to study two and three dimensional network structures formed by cytoskeletal polymer fibers such as actin filaments and microtubules. While these cytoskeletal structures are often dilute enough to allow imaging of individual filaments or bundles of them, quantitative analysis of these images is challenging. To facilitate quantitative, reproducible and objective analysis of the image data, we developed a semi-automated method to extract actin networks and retrieve their topology in 3D. Our method uses multiple Stretching Open Active Contours (SOACs) that are automatically initialized at image intensity ridges and then evolve along the centerlines of filaments in the network. SOACs can merge, stop at junctions, and reconfigure with others to allow smooth crossing at junctions of filaments. The proposed approach is generally applicable to images of curvilinear networks with low SNR. We demonstrate its potential by extracting the centerlines of synthetic meshwork images, actin networks in 2D TIRF Microscopy images, and 3D actin cable meshworks of live fission yeast cells imaged by spinning disk confocal microscopy.

  7. Radiometric and Geometric Accuracy Analysis of Rasat Pan Imagery

    NASA Astrophysics Data System (ADS)

    Kocaman, S.; Yalcin, I.; Guler, M.

    2016-06-01

    RASAT is the second Turkish Earth Observation satellite which was launched in 2011. It operates with pushbroom principle and acquires panchromatic and MS images with 7.5 m and 15 m resolutions, respectively. The swath width of the sensor is 30 km. The main aim of this study is to analyse the radiometric and geometric quality of RASAT images. A systematic validation approach for the RASAT imagery and its products is being applied. RASAT image pair acquired over Kesan city in Edirne province of Turkey are used for the investigations. The raw RASAT data (L0) are processed by Turkish Space Agency (TUBITAK-UZAY) to produce higher level image products. The image products include radiometrically processed (L1), georeferenced (L2) and orthorectified (L3) data, as well as pansharpened images. The image quality assessments include visual inspections, noise, MTF and histogram analyses. The geometric accuracy assessment results are only preliminary and the assessment is performed using the raw images. The geometric accuracy potential is investigated using 3D ground control points extracted from road intersections, which were measured manually in stereo from aerial images with 20 cm resolution and accuracy. The initial results of the study, which were performed using one RASAT panchromatic image pair, are presented in this paper.

  8. A statistical study of decaying kink oscillations detected using SDO/AIA

    NASA Astrophysics Data System (ADS)

    Goddard, C. R.; Nisticò, G.; Nakariakov, V. M.; Zimovets, I. V.

    2016-01-01

    Context. Despite intensive studies of kink oscillations of coronal loops in the last decade, a large-scale statistically significant investigation of the oscillation parameters has not been made using data from the Solar Dynamics Observatory (SDO). Aims: We carry out a statistical study of kink oscillations using extreme ultraviolet imaging data from a previously compiled catalogue. Methods: We analysed 58 kink oscillation events observed by the Atmospheric Imaging Assembly (AIA) on board SDO during its first four years of operation (2010-2014). Parameters of the oscillations, including the initial apparent amplitude, period, length of the oscillating loop, and damping are studied for 120 individual loop oscillations. Results: Analysis of the initial loop displacement and oscillation amplitude leads to the conclusion that the initial loop displacement prescribes the initial amplitude of oscillation in general. The period is found to scale with the loop length, and a linear fit of the data cloud gives a kink speed of Ck = (1330 ± 50) km s-1. The main body of the data corresponds to kink speeds in the range Ck = (800-3300) km s-1. Measurements of 52 exponential damping times were made, and it was noted that at least 21 of the damping profiles may be better approximated by a combination of non-exponential and exponential profiles rather than a purely exponential damping envelope. There are nine additional cases where the profile appears to be purely non-exponential and no damping time was measured. A scaling of the exponential damping time with the period is found, following the previously established linear scaling between these two parameters.

  9. Addressing the coming radiology crisis-the Society for Computer Applications in Radiology transforming the radiological interpretation process (TRIP) initiative.

    PubMed

    Andriole, Katherine P; Morin, Richard L; Arenson, Ronald L; Carrino, John A; Erickson, Bradley J; Horii, Steven C; Piraino, David W; Reiner, Bruce I; Seibert, J Anthony; Siegel, Eliot

    2004-12-01

    The Society for Computer Applications in Radiology (SCAR) Transforming the Radiological Interpretation Process (TRIP) Initiative aims to spearhead research, education, and discovery of innovative solutions to address the problem of information and image data overload. The initiative will foster interdisciplinary research on technological, environmental and human factors to better manage and exploit the massive amounts of data. TRIP will focus on the following basic objectives: improving the efficiency of interpretation of large data sets, improving the timeliness and effectiveness of communication, and decreasing medical errors. The ultimate goal of the initiative is to improve the quality and safety of patient care. Interdisciplinary research into several broad areas will be necessary to make progress in managing the ever-increasing volume of data. The six concepts involved are human perception, image processing and computer-aided detection (CAD), visualization, navigation and usability, databases and integration, and evaluation and validation of methods and performance. The result of this transformation will affect several key processes in radiology, including image interpretation; communication of imaging results; workflow and efficiency within the health care enterprise; diagnostic accuracy and a reduction in medical errors; and, ultimately, the overall quality of care.

  10. Evaluating the risk of appendiceal perforation when using ultrasound as the initial diagnostic imaging modality in children with suspected appendicitis.

    PubMed

    Alerhand, Stephen; Meltzer, James; Tay, Ee Tein

    2017-08-01

    Ultrasound scan has gained attention for diagnosing appendicitis due to its avoidance of ionizing radiation. However, studies show that ultrasound scan carries inferior sensitivity to computed tomography scan. A non-diagnostic ultrasound scan could increase the time to diagnosis and appendicectomy, particularly if follow-up computed tomography scan is needed. Some studies suggest that delaying appendicectomy increases the risk of perforation. To investigate the risk of appendiceal perforation when using ultrasound scan as the initial diagnostic imaging modality in children with suspected appendicitis. We retrospectively reviewed 1411 charts of children ≤17 years old diagnosed with appendicitis at two urban academic medical centers. Patients who underwent ultrasound scan first were compared to those who underwent computed tomography scan first. In the sub-group analysis, patients who only received ultrasound scan were compared to those who received initial ultrasound scan followed by computed tomography scan. Main outcome measures were appendiceal perforation rate and time from triage to appendicectomy. In 720 children eligible for analysis, there was no significant difference in perforation rate between those who had initial ultrasound scan and those who had initial computed tomography scan (7.3% vs. 8.9%, p = 0.44), nor in those who had ultrasound scan only and those who had initial ultrasound scan followed by computed tomography scan (8.0% vs. 5.6%, p = 0.42). Those patients who had ultrasound scan first had a shorter triage-to-incision time than those who had computed tomography scan first (9.2 (IQR: 5.9, 14.0) vs. 10.2 (IQR: 7.3, 14.3) hours, p = 0.03), whereas those who had ultrasound scan followed by computed tomography scan took longer than those who had ultrasound scan only (7.8 (IQR: 5.3, 11.6) vs. 15.1 (IQR: 10.6, 20.6), p < 0.001). Children < 12 years old receiving ultrasound scan first had lower perforation rate (p = 0.01) and shorter triage-to-incision time (p = 0.003). Children with suspected appendicitis receiving ultrasound scan as the initial diagnostic imaging modality do not have increased risk of perforation compared to those receiving computed tomography scan first. We recommend that children <12 years of age receive ultrasound scan first.

  11. 15 CFR 786.2 - Recordkeeping.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... recognized as complete words or numbers. (iv) The system must preserve the initial image (including both... the system. (3) Requirements applicable to a system based on digital images. For systems based on the storage of digital images, the system must provide accessibility to any digital image in the system. The...

  12. 15 CFR 786.2 - Recordkeeping.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... recognized as complete words or numbers. (iv) The system must preserve the initial image (including both... the system. (3) Requirements applicable to a system based on digital images. For systems based on the storage of digital images, the system must provide accessibility to any digital image in the system. The...

  13. 15 CFR 786.2 - Recordkeeping.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... recognized as complete words or numbers. (iv) The system must preserve the initial image (including both... the system. (3) Requirements applicable to a system based on digital images. For systems based on the storage of digital images, the system must provide accessibility to any digital image in the system. The...

  14. 15 CFR 786.2 - Recordkeeping.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... recognized as complete words or numbers. (iv) The system must preserve the initial image (including both... the system. (3) Requirements applicable to a system based on digital images. For systems based on the storage of digital images, the system must provide accessibility to any digital image in the system. The...

  15. 15 CFR 786.2 - Recordkeeping.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... recognized as complete words or numbers. (iv) The system must preserve the initial image (including both... the system. (3) Requirements applicable to a system based on digital images. For systems based on the storage of digital images, the system must provide accessibility to any digital image in the system. The...

  16. TU-FG-BRB-05: A 3 Dimensional Prompt Gamma Imaging System for Range Verification in Proton Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Draeger, E; Chen, H; Polf, J

    2016-06-15

    Purpose: To report on the initial developments of a clinical 3-dimensional (3D) prompt gamma (PG) imaging system for proton radiotherapy range verification. Methods: The new imaging system under development consists of a prototype Compton camera to measure PG emission during proton beam irradiation and software to reconstruct, display, and analyze 3D images of the PG emission. For initial test of the system, PGs were measured with a prototype CC during a 200 cGy dose delivery with clinical proton pencil beams (ranging from 100 MeV – 200 MeV) to a water phantom. Measurements were also carried out with the CC placedmore » 15 cm from the phantom for a full range 150 MeV pencil beam and with its range shifted by 2 mm. Reconstructed images of the PG emission were displayed by the clinical PG imaging software and compared to the dose distributions of the proton beams calculated by a commercial treatment planning system. Results: Measurements made with the new PG imaging system showed that a 3D image could be reconstructed from PGs measured during the delivery of 200 cGy of dose, and that shifts in the Bragg peak range of as little as 2 mm could be detected. Conclusion: Initial tests of a new PG imaging system show its potential to provide 3D imaging and range verification for proton radiotherapy. Based on these results, we have begun work to improve the system with the goal that images can be produced from delivery of as little as 20 cGy so that the system could be used for in-vivo proton beam range verification on a daily basis.« less

  17. Evaluation of breast tissue with confocal strip-mosaicking microscopy: a test approach emulating pathology-like examination

    PubMed Central

    Abeytunge, Sanjee; Larson, Bjorg; Peterson, Gary; Morrow, Monica; Rajadhyaksha, Milind

    2017-01-01

    Abstract. Confocal microscopy is an emerging technology for rapid imaging of freshly excised tissue without the need for frozen- or fixed-section processing. Initial studies have described imaging of breast tissue using fluorescence confocal microscopy with small regions of interest, typically 750×750  μm2. We present exploration with a microscope, termed confocal strip-mosaicking microscope (CSM microscope), which images an area of 2×2  cm2 of tissue with cellular-level resolution in 10 min of excision. Using the CSM microscope, we imaged 34 fresh, human, large breast tissue specimens from 18 patients, blindly analyzed by a board-certified pathologist and subsequently correlated with the corresponding standard fixed histopathology. Invasive tumors and benign tissue were clearly identified in CSM strip-mosaic images. Thirty specimens were concordant for image-to-histopathology correlation while four were discordant. PMID:28327961

  18. Initial results of finger imaging using photoacoustic computed tomography

    NASA Astrophysics Data System (ADS)

    van Es, Peter; Biswas, Samir K.; Moens, Hein J. Bernelot; Steenbergen, Wiendelt; Manohar, Srirang

    2014-06-01

    We present a photoacoustic computed tomography investigation on a healthy human finger, to image blood vessels with a focus on vascularity across the interphalangeal joints. The cross-sectional images were acquired using an imager specifically developed for this purpose. The images show rich detail of the digital blood vessels with diameters between 100 μm and 1.5 mm in various orientations and at various depths. Different vascular layers in the skin including the subpapillary plexus could also be visualized. Acoustic reflections on the finger bone of photoacoustic signals from skin were visible in sequential slice images along the finger except at the location of the joint gaps. Not unexpectedly, the healthy synovial membrane at the joint gaps was not detected due to its small size and normal vascularization. Future research will concentrate on studying digits afflicted with rheumatoid arthritis to detect the inflamed synovium with its heightened vascularization, whose characteristics are potential markers for disease activity.

  19. A feasibility study of X-ray phase-contrast mammographic tomography at the Imaging and Medical beamline of the Australian Synchrotron.

    PubMed

    Nesterets, Yakov I; Gureyev, Timur E; Mayo, Sheridan C; Stevenson, Andrew W; Thompson, Darren; Brown, Jeremy M C; Kitchen, Marcus J; Pavlov, Konstantin M; Lockie, Darren; Brun, Francesco; Tromba, Giuliana

    2015-11-01

    Results are presented of a recent experiment at the Imaging and Medical beamline of the Australian Synchrotron intended to contribute to the implementation of low-dose high-sensitivity three-dimensional mammographic phase-contrast imaging, initially at synchrotrons and subsequently in hospitals and medical imaging clinics. The effect of such imaging parameters as X-ray energy, source size, detector resolution, sample-to-detector distance, scanning and data processing strategies in the case of propagation-based phase-contrast computed tomography (CT) have been tested, quantified, evaluated and optimized using a plastic phantom simulating relevant breast-tissue characteristics. Analysis of the data collected using a Hamamatsu CMOS Flat Panel Sensor, with a pixel size of 100 µm, revealed the presence of propagation-based phase contrast and demonstrated significant improvement of the quality of phase-contrast CT imaging compared with conventional (absorption-based) CT, at medically acceptable radiation doses.

  20. Branding Access through the Carolina Covenant: Fostering Institutional Image and Brand

    ERIC Educational Resources Information Center

    Harris, Michael S.; Barnes, Bradley

    2011-01-01

    This study analyzes the potential of major financial aid initiatives to serve as key elements of an institutional branding strategy. Concepts of branding and marketing serve as guiding frameworks for the analysis and interpretation of the findings. Using a case study approach, data were collected through interviews and document analysis at the…

  1. Planning, expectation, and image evaluation for PACS at the University of Iowa Hospitals and Clinics

    NASA Astrophysics Data System (ADS)

    Franken, E. A., Jr.; Smith, Wilbur L.; Berbaum, Kevin S.; Owen, David A.; Hilsenrath, Peter

    1990-08-01

    Our strategy in studying PACS is to evaluate its clinical implementation working with equipment supplied by an established manufacturer. Fiscal and personnel resources required to design and integrate the hardware components and operational software to develop a functional PACS precluded a bottom up development approach at our institution. Imaging equipment vendors possess more abundant design development resources for this task and therefore can support a more rapid development of the initial components of PACS. For this reason we have chosen to serve as a beta test site to study the viability of the basic PACS components in a clinical setting. Our efforts primarily focus on: (1) image quality; (2) cost effectiveness; (3) PACS/HIS/RIS integration; (4) equipment and software reliability; and (5) overall system performance. The results of our studies are shared with the vendor for future PACS development and refi nement. To attain our investigational goals we have formed an interdisciplinary team of Radiologists, Perceptual Psychologist, Economist, Electrical and Industrial Engineers, Hospital Information System personnel and key departmental administrative staff. For several reasons Pediatric Radiology was targeted as the initial area for our PACS study: a small area representative of the overall operation,tight operational controls and willingness of physicians. We used a step-wise approach, the first step being the installation of PACS exclusively within the physical confines of Pediatric Radiology.

  2. Different methods of image segmentation in the process of meat marbling evaluation

    NASA Astrophysics Data System (ADS)

    Ludwiczak, A.; Ślósarz, P.; Lisiak, D.; Przybylak, A.; Boniecki, P.; Stanisz, M.; Koszela, K.; Zaborowicz, M.; Przybył, K.; Wojcieszak, D.; Janczak, D.; Bykowska, M.

    2015-07-01

    The level of marbling in meat assessment based on digital images is very popular, as computer vision tools are becoming more and more advanced. However considering muscle cross sections as the data source for marbling level evaluation, there are still a few problems to cope with. There is a need for an accurate method which would facilitate this evaluation procedure and increase its accuracy. The presented research was conducted in order to compare the effect of different image segmentation tools considering their usefulness in meat marbling evaluation on the muscle anatomical cross - sections. However this study is considered to be an initial trial in the presented field of research and an introduction to ultrasonic images processing and analysis.

  3. Iterative reconstruction of simulated low count data: a comparison of post-filtering versus regularised OSEM

    NASA Astrophysics Data System (ADS)

    Karaoglanis, K.; Efthimiou, N.; Tsoumpas, C.

    2015-09-01

    Low count PET data is a challenge for medical image reconstruction. The statistics of a dataset is a key factor of the quality of the reconstructed images. Reconstruction algorithms which would be able to compensate for low count datasets could provide the means to reduce the patient injected doses and/or reduce the scan times. It has been shown that the use of priors improve the image quality in low count conditions. In this study we compared regularised versus post-filtered OSEM for their performance on challenging simulated low count datasets. Initial visual comparison demonstrated that both algorithms improve the image quality, although the use of regularization does not introduce the undesired blurring as post-filtering.

  4. Surface grafted glycopolymer brushes to enhance selective adhesion of HepG2 cells.

    PubMed

    Chernyy, Sergey; Jensen, Bettina E B; Shimizu, Kyoko; Ceccato, Marcel; Pedersen, Steen Uttrup; Zelikin, Alexander N; Daasbjerg, Kim; Iruthayaraj, Joseph

    2013-08-15

    This work demonstrates the application of carbohydrate based methacrylate polymer brush, poly(2-lactobionamidoethyl methacrylate), for the purpose of cell adhesion studies. The first part of the work illustrates the effects of the structure of the aminosilane based ATRP initiator layer on the polymerization kinetics of 2-lactobionamidoethyl methacrylate) (LAMA) monomer on thermally oxidized silicon wafer. Both monolayer and multilayered aminosilane precursor layers have been prepared followed by reaction with 2-bromoisobutyrylbromide to form the ATRP initiator layer. It is inferred from the kinetic studies that the rate of termination is low on a multilayered initiator layer compared to a disordered monolayer structure. However both initiator types results in similar graft densities. Furthermore, it is shown that thick comb-like poly(LAMA) brushes can be constructed by initiating a second ATRP process on a previously formed poly(LAMA) brushes. The morphology of human hepatocellular carcinoma cancer cells (HepG2) on the comb-like poly(LAMA) brush layer has been studied. The fluorescent images of the HepG2 cells on the glycopolymer brush surface display distinct protrusions that extend outside of the cell periphery. On the other hand the cells on bare glass substrate display spheroid morphology. Further analysis using ToF-SIMS imaging shows that the HepG2 cells on glycopolymer surfaces is enriched with protein fragment along the cell periphery which is absent in the case of cells on bare glass substrate. It is suggested that the interaction of the galactose units of the polymer brush with the asialoglycoprotein receptor (ASGPR) of HepG2 cells has resulted in the protein enrichment along the cell periphery. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Image analysis for the automated estimation of clonal growth and its application to the growth of smooth muscle cells.

    PubMed

    Gavino, V C; Milo, G E; Cornwell, D G

    1982-03-01

    Image analysis was used for the automated measurement of colony frequency (f) and colony diameter (d) in cultures of smooth muscle cells, Initial studies with the inverted microscope showed that number of cells (N) in a colony varied directly with d: log N = 1.98 log d - 3.469 Image analysis generated the complement of a cumulative distribution for f as a function of d. The number of cells in each segment of the distribution function was calculated by multiplying f and the average N for the segment. These data were displayed as a cumulative distribution function. The total number of colonies (fT) and the total number of cells (NT) were used to calculate the average colony size (NA). Population doublings (PD) were then expressed as log2 NA. Image analysis confirmed previous studies in which colonies were sized and counted with an inverted microscope. Thus, image analysis is a rapid and automated technique for the measurement of clonal growth.

  6. Photoacoustic evaluation of human inflammatory arthritis in human joints

    NASA Astrophysics Data System (ADS)

    Jo, Janggun; Xu, Guan; Marquardt, April; Girish, Gandikota; Wang, Xueding

    2017-03-01

    Photoacoustic (PA) imaging combined with ultrasonography (US) holds promise to offer a novel and powerful tool for clinical management of inflammatory arthritis, including early detection and treatment monitoring. As a complement to US, PA imaging can assess additional hemodynamic changes in inflammatory synovium, including hyperemia and hypoxia, both important and early physiological biomarkers of synovitis reflecting the increased metabolic demand and the relatively inadequate oxygen delivery of the inflammatory synovial tissue. In this study on arthritis patients and normal volunteers, the targeted metacarpophalangeal (MCP) joints were imaged using our real-time US-PA dual-modality imaging system. The blood volume and the blood oxygenation in the segmented synovium were quantified, and the results from the arthritis patients were compared to those from the normal volunteers. This initial study on human subjects demonstrated that PA imaging, by working at the optical wavelengths that are sensitive to oxygenated and deoxygenated hemoglobin, is capable of identifying and characterizing inflammation in joints based on the detection of hemodynamic changes.

  7. Noninvasive Assessment of Biochemical and Mechanical Properties of Lumbar Discs Through Quantitative Magnetic Resonance Imaging in Asymptomatic Volunteers.

    PubMed

    Foltz, Mary H; Kage, Craig C; Johnson, Casey P; Ellingson, Arin M

    2017-11-01

    Intervertebral disc degeneration is a prevalent phenomenon associated with back pain. It is of critical clinical interest to discriminate disc health and identify early stages of degeneration. Traditional clinical T2-weighted magnetic resonance imaging (MRI), assessed using the Pfirrmann classification system, is subjective and fails to adequately capture initial degenerative changes. Emerging quantitative MRI techniques offer a solution. Specifically, T2* mapping images water mobility in the macromolecular network, and our preliminary ex vivo work shows high predictability of the disc's glycosaminoglycan content (s-GAG) and residual mechanics. The present study expands upon this work to predict the biochemical and biomechanical properties in vivo and assess their relationship with both age and Pfirrmann grade. Eleven asymptomatic subjects (range: 18-62 yrs) were enrolled and imaged using a 3T MRI scanner. T2-weighted images (Pfirrmann grade) and quantitative T2* maps (predict s-GAG and residual stress) were acquired. Surface maps based on the distribution of these properties were generated and integrated to quantify the surface volume. Correlational analyses were conducted to establish the relationship between each metric of disc health derived from the quantitative T2* maps with both age and Pfirrmann grade, where an inverse trend was observed. Furthermore, the nucleus pulposus (NP) signal in conjunction with volumetric surface maps provided the ability to discern differences during initial stages of disc degeneration. This study highlights the ability of T2* mapping to noninvasively assess the s-GAG content, residual stress, and distributions throughout the entire disc, which may provide a powerful diagnostic tool for disc health assessment.

  8. From Image Analysis to Computer Vision: Motives, Methods, and Milestones.

    DTIC Science & Technology

    1998-07-01

    images. Initially, work on digital image analysis dealt with specific classes of images such as text, photomicrographs, nuclear particle tracks, and aerial...photographs; but by the 1960’s, general algorithms and paradigms for image analysis began to be formulated. When the artificial intelligence...scene, but eventually from image sequences obtained by a moving camera; at this stage, image analysis had become scene analysis or computer vision

  9. Active imaging system performance model for target acquisition

    NASA Astrophysics Data System (ADS)

    Espinola, Richard L.; Teaney, Brian; Nguyen, Quang; Jacobs, Eddie L.; Halford, Carl E.; Tofsted, David H.

    2007-04-01

    The U.S. Army RDECOM CERDEC Night Vision & Electronic Sensors Directorate has developed a laser-range-gated imaging system performance model for the detection, recognition, and identification of vehicle targets. The model is based on the established US Army RDECOM CERDEC NVESD sensor performance models of the human system response through an imaging system. The Java-based model, called NVLRG, accounts for the effect of active illumination, atmospheric attenuation, and turbulence effects relevant to LRG imagers, such as speckle and scintillation, and for the critical sensor and display components. This model can be used to assess the performance of recently proposed active SWIR systems through various trade studies. This paper will describe the NVLRG model in detail, discuss the validation of recent model components, present initial trade study results, and outline plans to validate and calibrate the end-to-end model with field data through human perception testing.

  10. Ion imaging study of dissociative charge transfer in the N{sub 2}{sup +}+ CH{sub 4} system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pei Linsen; Farrar, James M.

    The velocity map ion imaging method is applied to the dissociative charge transfer reactions of N{sub 2}{sup +} with CH{sub 4} studied in crossed beams. The velocity space images are collected at four collision energies between 0.5 and 1.5 eV, providing both product kinetic energy and angular distributions for the reaction products CH{sub 3}{sup +} and CH{sub 2}{sup +}. The general shapes of the images are consistent with long range electron transfer from CH{sub 4} to N{sub 2}{sup +} preceding dissociation, and product kinetic energy distributions are consistent with energy resonance in the initial electron transfer step. The branching ratiomore » for CH{sub 3}{sup +}:CH{sub 2}{sup +} is 85:15 over the full collision energy range, consistent with literature reports.« less

  11. Representations in plastic surgery: the impact of self-image and self-confidence in the work environment.

    PubMed

    Foustanos, A; Pantazi, L; Zavrides, H

    2007-01-01

    This research was initiated by the authors' conviction that many people currently pay great attention to their personal appearance, which is directly linked to their self-confidence. The external image of individuals appears to have a decisive influence on their behavior and personal choices regarding both their personal and professional lives. Accordingly, it can be assumed that appearance influences professional choices and development. Moreover, individuals associate increased self-confidence with positive social images. Therefore, the main variables used in this study were self-image, self-confidence, and work environment. For the purpose of this study, the authors developed a questionnaire and distributed it to a sample of 100 women who had undergone aesthetic plastic surgery. The aim of the questionnaire was to discover the opinion of these women concerning the aforementioned assumptions. After the data processing and analysis, the authors concluded that the aforementioned variables are statistically significant and correlated.

  12. Computer-Aided Diagnostic (CAD) Scheme by Use of Contralateral Subtraction Technique

    NASA Astrophysics Data System (ADS)

    Nagashima, Hiroyuki; Harakawa, Tetsumi

    We developed a computer-aided diagnostic (CAD) scheme for detection of subtle image findings of acute cerebral infarction in brain computed tomography (CT) by using a contralateral subtraction technique. In our computerized scheme, the lateral inclination of image was first corrected automatically by rotating and shifting. The contralateral subtraction image was then derived by subtraction of reversed image from original image. Initial candidates for acute cerebral infarctions were identified using the multiple-thresholding and image filtering techniques. As the 1st step for removing false positive candidates, fourteen image features were extracted in each of the initial candidates. Halfway candidates were detected by applying the rule-based test with these image features. At the 2nd step, five image features were extracted using the overlapping scale with halfway candidates in interest slice and upper/lower slice image. Finally, acute cerebral infarction candidates were detected by applying the rule-based test with five image features. The sensitivity in the detection for 74 training cases was 97.4% with 3.7 false positives per image. The performance of CAD scheme for 44 testing cases had an approximate result to training cases. Our CAD scheme using the contralateral subtraction technique can reveal suspected image findings of acute cerebral infarctions in CT images.

  13. A robust and fast active contour model for image segmentation with intensity inhomogeneity

    NASA Astrophysics Data System (ADS)

    Ding, Keyan; Weng, Guirong

    2018-04-01

    In this paper, a robust and fast active contour model is proposed for image segmentation in the presence of intensity inhomogeneity. By introducing the local image intensities fitting functions before the evolution of curve, the proposed model can effectively segment images with intensity inhomogeneity. And the computation cost is low because the fitting functions do not need to be updated in each iteration. Experiments have shown that the proposed model has a higher segmentation efficiency compared to some well-known active contour models based on local region fitting energy. In addition, the proposed model is robust to initialization, which allows the initial level set function to be a small constant function.

  14. Near-infrared fluorescence sentinel lymph node mapping in breast cancer: a multicenter experience

    PubMed Central

    Verbeek, Floris P.R.; Troyan, Susan L.; Mieog, J. Sven D.; Liefers, Gerrit-Jan; Moffitt, Lorissa A.; Rosenberg, Mireille; Hirshfield-Bartek, Judith; Gioux, Sylvain; van de Velde, Cornelis J.H.; Vahrmeijer, Alexander L.; Frangioni, John V.

    2014-01-01

    NIR fluorescence imaging using indocyanine green (ICG) has the potential to improve the SLN procedure by facilitating percutaneous and intraoperative identification of lymphatic channels and SLNs. Previous studies suggested that a dose of 0.62 mg (1.6 ml of 0.5 mM) ICG is optimal for SLN mapping in breast cancer. The aim of this study was to evaluate the diagnostic accuracy of near-infrared (NIR) fluorescence for sentinel lymph node (SLN) mapping in breast cancer patients when used in conjunction with conventional techniques. Study subjects were 95 breast cancer patients planning to undergo SLN procedure at either the Dana-Farber/Harvard Cancer Center (Boston, MA, USA) or the Leiden University Medical Center (Leiden, the Netherlands) between July 2010 and January 2013. Subjects underwent the standard-of-care SLN procedure at each institution using 99Technetium-colloid in all subjects and patent blue in 27 (28%) of the subjects. NIR fluorescence-guided SLN detection was performed using the Mini-FLARE imaging system. SLN identification was successful in 94 of 95 subjects (99%) using NIR fluorescence imaging or a combination of both NIR fluorescence imaging and radioactive guidance. In 2 of 95 subjects, radioactive guidance was necessary for initial in vivo identification of SLNs. In 1 of 95 subjects, NIR fluorescence was necessary for initial in vivo identification of SLNs. A total of 177 SLNs (mean = 1.9, range = 1–5) were resected: 100% NIR fluorescent, 88% radioactive, and 78% (of 40 nodes) blue. In 2 of 95 subjects (2.1%), SLNs containing macrometastases were found only by NIR fluorescence, and in 1 patient this led to upstaging to N1. This study demonstrates the safe and accurate application of NIR fluorescence imaging for the identification of SLNs in breast cancer patients, but calls into question what technique should be used as the gold standard in future studies. PMID:24337507

  15. Fast auto-focus scheme based on optical defocus fitting model

    NASA Astrophysics Data System (ADS)

    Wang, Yeru; Feng, Huajun; Xu, Zhihai; Li, Qi; Chen, Yueting; Cen, Min

    2018-04-01

    An optical defocus fitting model-based (ODFM) auto-focus scheme is proposed. Considering the basic optical defocus principle, the optical defocus fitting model is derived to approximate the potential-focus position. By this accurate modelling, the proposed auto-focus scheme can make the stepping motor approach the focal plane more accurately and rapidly. Two fitting positions are first determined for an arbitrary initial stepping motor position. Three images (initial image and two fitting images) at these positions are then collected to estimate the potential-focus position based on the proposed ODFM method. Around the estimated potential-focus position, two reference images are recorded. The auto-focus procedure is then completed by processing these two reference images and the potential-focus image to confirm the in-focus position using a contrast based method. Experimental results prove that the proposed scheme can complete auto-focus within only 5 to 7 steps with good performance even under low-light condition.

  16. A Quadratic Spring Equation

    ERIC Educational Resources Information Center

    Fay, Temple H.

    2010-01-01

    Through numerical investigations, we study examples of the forced quadratic spring equation [image omitted]. By performing trial-and-error numerical experiments, we demonstrate the existence of stability boundaries in the phase plane indicating initial conditions yielding bounded solutions, investigate the resonance boundary in the [omega]…

  17. Computational photoacoustic imaging with sparsity-based optimization of the initial pressure distribution

    NASA Astrophysics Data System (ADS)

    Shang, Ruibo; Archibald, Richard; Gelb, Anne; Luke, Geoffrey P.

    2018-02-01

    In photoacoustic (PA) imaging, the optical absorption can be acquired from the initial pressure distribution (IPD). An accurate reconstruction of the IPD will be very helpful for the reconstruction of the optical absorption. However, the image quality of PA imaging in scattering media is deteriorated by the acoustic diffraction, imaging artifacts, and weak PA signals. In this paper, we propose a sparsity-based optimization approach that improves the reconstruction of the IPD in PA imaging. A linear imaging forward model was set up based on time-and-delay method with the assumption that the point spread function (PSF) is spatial invariant. Then, an optimization equation was proposed with a regularization term to denote the sparsity of the IPD in a certain domain to solve this inverse problem. As a proof of principle, the approach was applied to reconstructing point objects and blood vessel phantoms. The resolution and signal-to-noise ratio (SNR) were compared between conventional back-projection and our proposed approach. Overall these results show that computational imaging can leverage the sparsity of PA images to improve the estimation of the IPD.

  18. Automatic localization of landmark sets in head CT images with regression forests for image registration initialization

    NASA Astrophysics Data System (ADS)

    Zhang, Dongqing; Liu, Yuan; Noble, Jack H.; Dawant, Benoit M.

    2016-03-01

    Cochlear Implants (CIs) are electrode arrays that are surgically inserted into the cochlea. Individual contacts stimulate frequency-mapped nerve endings thus replacing the natural electro-mechanical transduction mechanism. CIs are programmed post-operatively by audiologists but this is currently done using behavioral tests without imaging information that permits relating electrode position to inner ear anatomy. We have recently developed a series of image processing steps that permit the segmentation of the inner ear anatomy and the localization of individual contacts. We have proposed a new programming strategy that uses this information and we have shown in a study with 68 participants that 78% of long term recipients preferred the programming parameters determined with this new strategy. A limiting factor to the large scale evaluation and deployment of our technique is the amount of user interaction still required in some of the steps used in our sequence of image processing algorithms. One such step is the rough registration of an atlas to target volumes prior to the use of automated intensity-based algorithms when the target volumes have very different fields of view and orientations. In this paper we propose a solution to this problem. It relies on a random forest-based approach to automatically localize a series of landmarks. Our results obtained from 83 images with 132 registration tasks show that automatic initialization of an intensity-based algorithm proves to be a reliable technique to replace the manual step.

  19. Calibrating AIS images using the surface as a reference

    NASA Technical Reports Server (NTRS)

    Smith, M. O.; Roberts, D. A.; Shipman, H. M.; Adams, J. B.; Willis, S. C.; Gillespie, A. R.

    1987-01-01

    A method of evaluating the initial assumptions and uncertainties of the physical connection between Airborne Imaging Spectrometer (AIS) image data and laboratory/field spectrometer data was tested. The Tuscon AIS-2 image connects to lab reference spectra by an alignment to the image spectral endmembers through a system gain and offset for each band. Images were calibrated to reflectance so as to transform the image into a measure that is independent of the solar radiant flux. This transformation also makes the image spectra directly comparable to data from lab and field spectrometers. A method was tested for calibrating AIS images using the surface as a reference. The surface heterogeneity is defined by lab/field spectral measurements. It was found that the Tuscon AIS-2 image is consistent with each of the initial hypotheses: (1) that the AIS-2 instrument calibration is nearly linear; (2) the spectral variance is caused by sub-pixel mixtures of spectrally distinct materials and shade, and (3) that sub-pixel mixtures can be treated as linear mixtures of pure endmembers. It was also found that the image can be characterized by relatively few endmembers using the AIS-2 spectra.

  20. Delayed Temporal Lobe Hemorrhage After Initiation of Acyclovir in an Immunocompetent Patient with Herpes Simplex Virus-2 Encephalitis: A Case Report.

    PubMed

    Mueller, Kyle; Ryan, Joshua E; Tai, Alex; Armonda, Rocco A

    2017-01-15

    Herpes simplex virus (HSV) is the most common cause of non-epidemic, sporadic, acute focal encephalitis in the United States. Inflammation of the vasculature makes them friable and susceptible to hemorrhage. Massive hemorrhage, though rare, can present in a delayed fashion after initiation of acyclovir and often requires surgical intervention. We report a unique case of delayed temporal lobe hemorrhage after initiation of acyclovir in an immunocompetent patient, specifically for its presentation, virology, and surgical management. A 40-year-old left-handed Caucasian female with chronic headaches, along with a 20-pack-year smoking history, presented to an outside facility with one week of diffuse, generalized headache, fever, nausea, and vomiting. Initial cranial imaging was negative for hemorrhage. Cerebrospinal fluid (CSF) studies showed a lymphocytic pleocytosis with elevated protein, along with polymerase chain reaction (PCR) positive staining for HSV, establishing the diagnosis of HSV-2 encephalitis, which is less common in adults. Acyclovir was initiated and one week later while still hospitalized, the patient developed acute altered mental status with cranial imaging showing a large right temporal lobe hemorrhage with significant midline shift. She was transferred to our facility for surgical intervention. Computed tomography angiography (CTA) was negative for any underlying vascular lesion. She was taken to the operating room for a decompressive unilateral (right) hemicraniectomy and temporal lobectomy. She had no postoperative complications and completed a three-week course of acyclovir. She was discharged to acute rehab with plans to return at a later date for cranioplasty. Intracerebral hemorrhage is an uncommon, although possible sequela, of herpes encephalitis. Despite initiation of early antiviral therapy, close monitoring is warranted, given the pathophysiology of the vasculature. Any decline in the neurological exam and/or increasing symptomatology of increased intracranial pressure mandates immediate cranial imaging to evaluate for possible hemorrhage. Emergent surgical intervention is warranted with large temporal lobe hemorrhages.

  1. Estimating optical imaging system performance for space applications

    NASA Technical Reports Server (NTRS)

    Sinclair, K. F.

    1972-01-01

    The critical system elements of an optical imaging system are identified and a method for an initial assessment of system performance is presented. A generalized imaging system is defined. A system analysis is considered, followed by a component analysis. An example of the method is given using a film imaging system.

  2. An Imaging Roadmap for Biology Education: From Nanoparticles to Whole Organisms

    ERIC Educational Resources Information Center

    Kelley, Daniel J.; Davidson, Richard J.; Nelson, David L.

    2008-01-01

    Imaging techniques provide ways of knowing structure and function in biology at different scales. The multidisciplinary nature and rapid advancement of imaging sciences requires imaging education to begin early in the biology curriculum. Guided by the National Institutes of Health (NIH) Roadmap initiatives, we incorporated a nanoimaging, molecular…

  3. Intra- and inter-observer reliability of quantitative analysis of the infra-patellar fat pad and comparison between fat- and non-fat-suppressed imaging--Data from the osteoarthritis initiative.

    PubMed

    Steidle-Kloc, E; Wirth, W; Ruhdorfer, A; Dannhauer, T; Eckstein, F

    2016-03-01

    The infra-patellar fat pad (IPFP), as intra-articular adipose tissue represents a potential source of pro-inflammatory cytokines and its size has been suggested to be associated with osteoarthritis (OA) of the knee. This study examines inter- and intra-observer reliability of fat-suppressed (fs) and non-fat-suppressed (nfs) MR imaging for determination of IPFP morphological measurements as novel biomarkers. The IPFP of nine right knees of healthy Osteoarthritis Initiative participants was segmented by five readers, using fs and nfs baseline sagittal MRIs. The intra-observer reliability was determined from baseline and 1-year follow-up images. All segmentations were quality controlled (QC) by an expert reader. Reliability was expressed as root mean square coefficient of variation (RMS CV%). After QC, the inter-observer reliability for fs (nfs) imaging was 2.0% (1.1%) for IPFP volume, 2.1%/2.5% (1.6%/1.8%) for anterior/posterior surface areas, 1.8% (1.8%) for depth, and 2.1% (2.4%) for maximum sagittal area. The intra-observer reliability was 3.1% (5.0%) for volume, 2.3%/2.8% (2.5%/2.9%) for anterior/posterior surfaces, 1.9% (3.5%) for depth, and 3.3% (4.5%) for maximum sagittal area. IPFP volume from nfs images was systematically greater (+7.3%) than from fs images, but highly correlated (r=0.98). The results suggest that quantitative measurements of IPFP morphology can be performed with satisfactory reliability when expert QC is implemented. The IPFP is more clearly depicted in nfs images, and there is a small systematic off-set versus analysis from fs images. However, the high linear relationship between fs and nfs imaging suggests that fs images can be used to analyze IPFP morphology, when nfs images are not available. Copyright © 2015 Elsevier GmbH. All rights reserved.

  4. X-ray tests of a microchannel plate detector and amorphous silicon pixel array readout for neutron radiography

    NASA Astrophysics Data System (ADS)

    Ambrosi, R. M.; Street, R.; Feller, B.; Fraser, G. W.; Watterson, J. I. W.; Lanza, R. C.; Dowson, J.; Ross, D.; Martindale, A.; Abbey, A. F.; Vernon, D.

    2007-03-01

    High-performance large area imaging detectors for fast neutrons in the 5-14 MeV energy range do not exist at present. The aim of this project is to combine microchannel plates or MCPs (or similar electron multiplication structures) traditionally used in image intensifiers and X-ray detectors with amorphous silicon (a-Si) pixel arrays to produce a composite converter and intensifier position sensitive imaging system. This detector will provide an order of magnitude improvement in image resolution when compared with current millimetre resolution limits obtained using phosphor or scintillator-based hydrogen rich converters. In this study we present the results of the initial experimental evaluation of the prototype system. This study was carried out using a medical X-ray source for the proof of concept tests, the next phase will involve neutron imaging tests. The hybrid detector described in this study is a unique development and paves the way for large area position sensitive detectors consisting of MCP or microsphere plate detectors and a-Si or polysilicon pixel arrays. Applications include neutron and X-ray imaging for terrestrial applications. The technology could be extended to space instrumentation for X-ray astronomy.

  5. Abdominal Sarcoidosis Mimicking Peritoneal Carcinomatosis.

    PubMed

    Roh, Won Seok; Lee, Seungho; Park, Ji Hyun; Kang, Jeonghyun

    2018-04-01

    We present a patient diagnosed with skin sarcoidosis, breast cancer, pulmonary tuberculosis, and peritoneal sarcoidosis with a past history of colorectal cancer. During stage work up for breast cancer, suspicious lesions on peritoneum were observed in imaging studies. Considering our patient's history and imaging findings, we initially suspected peritoneal carcinomatosis. However, the peritoneal lesion was diagnosed as sarcoidosis in laparoscopic biopsy. This case demonstrates that abdominal sarcoidosis might be considered as a differential diagnosis when there is a lesion suspected of being peritoneal carcinomatosis with nontypical clinical presentations.

  6. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    NASA Astrophysics Data System (ADS)

    Gaona, Enrique; Alfonso, Beatriz Y. Álvarez; Castellanos, Gustavo Casian; Enríquez, Jesús Gabriel Franco

    2008-08-01

    The goal of the study was to evaluate the first CR digital mammography system (® Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.

  7. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaona, Enrique; Enriquez, Jesus Gabriel Franco; Alfonso, Beatriz Y. Alvarez

    2008-08-11

    The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CRmore » Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.« less

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buckley, L; Lambert, C; Nyiri, B

    Purpose: To standardize the tube calibration for Elekta XVI cone beam CT (CBCT) systems in order to provide a meaningful estimate of the daily imaging dose and reduce the variation between units in a large centre with multiple treatment units. Methods: Initial measurements of the output from the CBCT systems were made using a Farmer chamber and standard CTDI phantom. The correlation between the measured CTDI and the tube current was confirmed using an Unfors Xi detector which was then used to perform a tube current calibration on each unit. Results: Initial measurements showed measured tube current variations of upmore » to 25% between units for scans with the same image settings. In order to reasonably estimate the imaging dose, a systematic approach to x-ray generator calibration was adopted to ensure that the imaging dose was consistent across all units at the centre and was adopted as part of the routine quality assurance program. Subsequent measurements show that the variation in measured dose across nine units is on the order of 5%. Conclusion: Increasingly, patients receiving radiation therapy have extended life expectancies and therefore the cumulative dose from daily imaging should not be ignored. In theory, an estimate of imaging dose can be made from the imaging parameters. However, measurements have shown that there are large differences in the x-ray generator calibration as installed at the clinic. Current protocols recommend routine checks of dose to ensure constancy. The present study suggests that in addition to constancy checks on a single machine, a tube current calibration should be performed on every unit to ensure agreement across multiple machines. This is crucial at a large centre with multiple units in order to provide physicians with a meaningful estimate of the daily imaging dose.« less

  9. Noninvasive imaging of three-dimensional cardiac activation sequence during pacing and ventricular tachycardia.

    PubMed

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-08-01

    Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. This study sought to rigorously assess the imaging performance of a 3-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of 3D intracardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE)-induced ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in 13 healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computed tomography images were obtained to construct geometry models. The noninvasively imaged activation sequence correlated well with invasively measured counterpart, with a correlation coefficient of 0.72 ± 0.04, and a relative error of 0.30 ± 0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from the imaged site of initial activation to the pacing site or site of arrhythmias determined from intracardiac mapping was ∼5 mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. 3DCEI can noninvasively delineate important features of focal or multifocal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequences of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  10. Noninvasive Imaging of Three-dimensional Cardiac Activation Sequence during Pacing and Ventricular Tachycardia

    PubMed Central

    Han, Chengzong; Pogwizd, Steven M.; Killingsworth, Cheryl R.; He, Bin

    2011-01-01

    Background Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. Objective This study aims to rigorously assess the imaging performance of a three-dimensional (3-D) cardiac electrical imaging (3-DCEI) technique with the aid of 3-D intra-cardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE) induced ventricular tachycardia (VT) in the rabbit heart. Methods Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in thirteen healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computer tomography images were obtained to construct geometry model. Results The non-invasively imaged activation sequence correlated well with invasively measured counterparts, with a correlation coefficient of 0.72±0.04, and a relative error of 0.30±0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from imaged site of initial activation to pacing site or site of arrhythmias determined from intra-cardiac mapping was ~5mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. Conclusion 3-DCEI can non-invasively delineate important features of focal or multi-focal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequence of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. PMID:21397046

  11. Initial evaluation of discrete orthogonal basis reconstruction of ECT images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moody, E.B.; Donohue, K.D.

    1996-12-31

    Discrete orthogonal basis restoration (DOBR) is a linear, non-iterative, and robust method for solving inverse problems for systems characterized by shift-variant transfer functions. This simulation study evaluates the feasibility of using DOBR for reconstructing emission computed tomographic (ECT) images. The imaging system model uses typical SPECT parameters and incorporates the effects of attenuation, spatially-variant PSF, and Poisson noise in the projection process. Sample reconstructions and statistical error analyses for a class of digital phantoms compare the DOBR performance for Hartley and Walsh basis functions. Test results confirm that DOBR with either basis set produces images with good statistical properties. Nomore » problems were encountered with reconstruction instability. The flexibility of the DOBR method and its consistent performance warrants further investigation of DOBR as a means of ECT image reconstruction.« less

  12. Efficacy of prophylactic cranial irradiation in patients with limited-disease small-cell lung cancer who were confirmed to have no brain metastasis via magnetic resonance imaging after initial chemoradiotherapy.

    PubMed

    Mamesaya, Nobuaki; Wakuda, Kazushige; Omae, Katsuhiro; Miyawaki, Eriko; Kotake, Mie; Fujiwara, Takumi; Kawamura, Takahisa; Kobayashi, Haruki; Nakashima, Kazuhisa; Omori, Shota; Ono, Akira; Kenmotsu, Hirotsugu; Naito, Tateaki; Murakami, Haruyasu; Mori, Keita; Harada, Hideyuki; Endo, Masahiro; Nakajima, Takashi; Takahashi, Toshiaki

    2018-04-03

    Prophylactic cranial irradiation (PCI) is recommended for patients with limited-disease small-cell lung cancer (LD-SCLC) who achieved good response to definitive chemoradiotherapy. However, most clinical studies lacked brain imaging scans before PCI. Our study aimed to investigate whether PCI has a survival benefit in patients who have no brain metastases (BM) confirmed via magnetic resonance imaging (MRI) before PCI. Eighty patients were included in this study. Sixty patients received PCI (PCI group) and 20 patients did not (non-PCI group). OS was not significantly different between the two groups. The median OS time was 4.3 years (95% CI: 2.6 years-8.6 years) in the PCI group and was not reached (NR) (95% CI: 1.9 years-NR) in the non-PCI group ( p = 0.542). Moreover, no differences were observed in the 3-year rates of PFS (46.2% and 44.4%, p = 0.720) and cumulative incidence of BM (24.0% vs. 27%, p = 0.404). Our result suggests that PCI may not have a survival benefit in patients with LD-SCLC confirmed to have no BM after initial therapy, even if patients achieve a good response to definitive chemoradiotherapy. We retrospectively evaluated patients with LD-SCLC who were confirmed to have no BM via MRI after initial chemoradiotherapy at the Shizuoka Cancer Center between September 2002 and August 2015. The overall survival (OS), progression-free survival (PFS), and cumulative incidence of BM were estimated using the Kaplan-Meier method between patients who received PCI and those who did not. Propensity score matching was used to balance baseline characteristics.

  13. Efficacy of prophylactic cranial irradiation in patients with limited-disease small-cell lung cancer who were confirmed to have no brain metastasis via magnetic resonance imaging after initial chemoradiotherapy

    PubMed Central

    Mamesaya, Nobuaki; Wakuda, Kazushige; Omae, Katsuhiro; Miyawaki, Eriko; Kotake, Mie; Fujiwara, Takumi; Kawamura, Takahisa; Kobayashi, Haruki; Nakashima, Kazuhisa; Omori, Shota; Ono, Akira; Kenmotsu, Hirotsugu; Naito, Tateaki; Murakami, Haruyasu; Mori, Keita; Harada, Hideyuki; Endo, Masahiro; Nakajima, Takashi; Takahashi, Toshiaki

    2018-01-01

    Background Prophylactic cranial irradiation (PCI) is recommended for patients with limited-disease small-cell lung cancer (LD-SCLC) who achieved good response to definitive chemoradiotherapy. However, most clinical studies lacked brain imaging scans before PCI. Our study aimed to investigate whether PCI has a survival benefit in patients who have no brain metastases (BM) confirmed via magnetic resonance imaging (MRI) before PCI. Results Eighty patients were included in this study. Sixty patients received PCI (PCI group) and 20 patients did not (non-PCI group). OS was not significantly different between the two groups. The median OS time was 4.3 years (95% CI: 2.6 years–8.6 years) in the PCI group and was not reached (NR) (95% CI: 1.9 years–NR) in the non-PCI group (p = 0.542). Moreover, no differences were observed in the 3-year rates of PFS (46.2% and 44.4%, p = 0.720) and cumulative incidence of BM (24.0% vs. 27%, p = 0.404). Conclusions Our result suggests that PCI may not have a survival benefit in patients with LD-SCLC confirmed to have no BM after initial therapy, even if patients achieve a good response to definitive chemoradiotherapy. Patients and Methods We retrospectively evaluated patients with LD-SCLC who were confirmed to have no BM via MRI after initial chemoradiotherapy at the Shizuoka Cancer Center between September 2002 and August 2015. The overall survival (OS), progression-free survival (PFS), and cumulative incidence of BM were estimated using the Kaplan–Meier method between patients who received PCI and those who did not. Propensity score matching was used to balance baseline characteristics. PMID:29707139

  14. #LancerHealth: Using Twitter and Instagram as a tool in a campus wide health promotion initiative

    PubMed Central

    Santarossa, Sara; Woodruff, Sarah J.

    2018-01-01

    The present study aimed to explore using popular technology that people already have/use as a health promotion tool, in a campus wide social media health promotion initiative, entitled #LancerHealth. During a two-week period the university community was asked to share photos on Twitter and Instagram of What does being healthy on campus look like to you?, while tagging the image with #LancerHealth. All publically tagged media was collected using the Netlytic software and analysed. Text analysis (N=234 records, Twitter; N=141 records, Instagram) revealed that the majority of the conversation was positive and focused on health and the university. Social network analysis, based on five network properties, showed a small network with little interaction. Lastly, photo coding analysis (N=71 unique image) indicated that the majority of the shared images were of physical activity (52%) and on campus (80%). Further research into this area is warranted. Significance for public healthAs digital media continues to become a popular tool among both public health organizations and those in academia, it is important to understand how, why, and which platforms individuals are using in regards to their health. This campus wide, social media health promotion initiative found that people will use popular social networking sites like Twitter and Instagram to share their healthy behaviours. Online social networks, created through social networking sites, can play a role in social diffusion of public health information and health behaviours. In this study, however, social network analysis revealed that there needs to be influential and highly connected individuals sharing information to generate social diffusion. This study can help guide future public health research in the area of social media and its potential influence on health promotion. PMID:29780763

  15. CATEGORICAL AND CORRELATIONAL ANALYSES OF BASELINE FLUORODEOXYGLUCOSE POSITRON EMISSION TOMOGRAPHY IMAGES FROM THE ALZHEIMER’S DISEASE NEUROIMAGING INITIATIVE (ADNI)

    PubMed Central

    Langbaum, Jessica B.S.; Chen, Kewei; Lee, Wendy; Reschke, Cole; Bandy, Dan; Fleisher, Adam S.; Alexander, Gene E.; Foster, Norman L.; Weiner, Michael W.; Koeppe, Robert A.; Jagust, William J.; Reiman, Eric M.

    2010-01-01

    In mostly small single-center studies, Alzheimer’s disease (AD) is associated with characteristic and progressive reductions in fluorodeoxyglucose positron emission tomography (PET) measurements of the regional cerebral metabolic rate for glucose (CMRgl). The AD Neuroimaging Initiative (ADNI) is acquiring FDG PET, volumetric magnetic resonance imaging, and other biomarker measurements in a large longitudinal multi-center study of initially mildly affected probable AD (pAD) patients, amnestic mild cognitive impairment (aMCI) patients, who are at increased AD risk, and cognitively normal controls (NC), and we are responsible for analyzing the PET images using statistical parametric mapping (SPM). Here we compare baseline CMRgl measurements from 74 pAD patients and 142 aMCI patients to those from 82 NC, we correlate CMRgl with categorical and continuous measures of clinical disease severity, and we compare apolipoprotein E (APOE) ε4 carriers to non-carriers in each of these subject groups. In comparison with NC, the pAD and aMCI groups each had significantly lower CMRgl bilaterally in posterior cingulate, precuneus, parietotemporal and frontal cortex. Similar reductions were observed when categories of disease severity or lower Mini-Mental State Exam (MMSE) scores were correlated with lower CMRgl. However, when analyses were restricted to the pAD patients, lower MMSE scores were significantly correlated with lower left frontal and temporal CMRgl. These findings from a large, multi-site study support previous single-site findings, supports the characteristic pattern of baseline CMRgl reductions in AD and aMCI patients, as well as preferential anterior CMRgl reductions after the onset of AD dementia. PMID:19349228

  16. A tractable prescription for large-scale free flight expansion of wavefunctions

    NASA Astrophysics Data System (ADS)

    Deuar, P.

    2016-11-01

    A numerical recipe is given for obtaining the density image of an initially compact quantum mechanical wavefunction that has expanded by a large but finite factor under free flight. The recipe given avoids the memory storage problems that plague this type of calculation by reducing the problem to the sum of a number of fast Fourier transforms carried out on the relatively small initial lattice. The final expanded state is given exactly on a coarser magnified grid with the same number of points as the initial state. An important application of this technique is the simulation of measured time-of-flight images in ultracold atom experiments, especially when the initial clouds contain superfluid defects. It is shown that such a finite-time expansion, rather than a far-field approximation is essential to correctly predict images of defect-laden clouds, even for long flight times. Examples shown are: an expanding quasicondensate with soliton defects and a matter-wave interferometer in 3D.

  17. Value of Surveillance Studies for Patients With Stage I to II Diffuse Large B-Cell Lymphoma in the Rituximab Era

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hiniker, Susan M.; Pollom, Erqi L.; Khodadoust, Michael S.

    2015-05-01

    Background: The role of surveillance studies in limited-stage diffuse large B-cell lymphoma (DLBCL) in the rituximab era has not been well defined. We sought to evaluate the use of imaging (computed tomography [CT] and positron emission tomography [PET]-CT) scans and lactate dehydrogenase (LDH) in surveillance of patients with stage I to II DLBCL. Methods: A retrospective analysis was performed of patients who received definitive treatment between 2000 and 2013. Results: One hundred sixty-two consecutive patients with stage I to II DLBCL were treated with chemotherapy +/− rituximab, radiation, or combined modality therapy. The 5-year rates of overall survival (OS) and freedommore » from progression (FFP) were 81.2% and 80.8%, respectively. Of the 162 patients, 124 (77%) were followed up with at least 1 surveillance PET scan beyond end-of-treatment scans; of those, 94 of 124 (76%) achieved a complete metabolic response on PET scan after completion of chemotherapy, and this was associated with superior FFP (P=.01, HR=0.3) and OS (P=.01, HR 0.3). Eighteen patients experienced relapse after initial response to therapy. Nine relapses were initially suspected by surveillance imaging studies (8 PET, 1 CT), and 9 were suspected clinically (5 by patient-reported symptoms and 4 by symptoms and physical examination). No relapses were detected by surveillance LDH. The median duration from initiation of treatment to relapse was 14.3 months among patients with relapses suspected by imaging, and 59.8 months among patients with relapses suspected clinically (P=.077). There was no significant difference in OS from date of first therapy or OS after relapse between patients whose relapse was suspected by imaging versus clinically. Thirteen of 18 patients underwent successful salvage therapy after relapse. Conclusions: A complete response on PET scan immediately after initial chemotherapy is associated with superior FFP and OS in stage I to II DLBCL. The use of PET scans as posttreatment surveillance is not associated with a survival advantage. LDH is not a sensitive marker for relapse. Our results argue for limiting the use of posttreatment surveillance in patients with limited-stage DLBCL.« less

  18. A Hybrid Method for Pancreas Extraction from CT Image Based on Level Set Methods

    PubMed Central

    Tan, Hanqing; Fujita, Hiroshi

    2013-01-01

    This paper proposes a novel semiautomatic method to extract the pancreas from abdominal CT images. Traditional level set and region growing methods that request locating initial contour near the final boundary of object have problem of leakage to nearby tissues of pancreas region. The proposed method consists of a customized fast-marching level set method which generates an optimal initial pancreas region to solve the problem that the level set method is sensitive to the initial contour location and a modified distance regularized level set method which extracts accurate pancreas. The novelty in our method is the proper selection and combination of level set methods, furthermore an energy-decrement algorithm and an energy-tune algorithm are proposed to reduce the negative impact of bonding force caused by connected tissue whose intensity is similar with pancreas. As a result, our method overcomes the shortages of oversegmentation at weak boundary and can accurately extract pancreas from CT images. The proposed method is compared to other five state-of-the-art medical image segmentation methods based on a CT image dataset which contains abdominal images from 10 patients. The evaluated results demonstrate that our method outperforms other methods by achieving higher accuracy and making less false segmentation in pancreas extraction. PMID:24066016

  19. Missed Diagnosis of Syrinx

    PubMed Central

    Oh, Chang Hyun; Kim, Chan Gyu; Lee, Jae-Hwan; Park, Hyeong-Chun; Park, Chong Oon

    2012-01-01

    Study Design Prospective, randomized, controlled human study. Purpose We checked the proportion of missed syrinx diagnoses among the examinees of the Korean military conscription. Overview of Literature A syrinx is a fluid-filled cavity within the spinal cord or brain stem and causes various neurological symptoms. A syrinx could easily be diagnosed by magnetic resonance image (MRI), but missed diagnoses seldom occur. Methods In this study, we reviewed 103 cases using cervical images, cervical MRI, or whole spine sagittal MRI, and syrinxes was observed in 18 of these cases. A review of medical certificates or interviews was conducted, and the proportion of syrinx diagnoses was calculated. Results The proportion of syrinx diagnoses was about 66.7% (12 cases among 18). Missed diagnoses were not the result of the length of the syrinx, but due to the type of image used for the initial diagnosis. Conclusions The missed diagnosis proportion of the syrinx is relatively high, therefore, a more careful imaging review is recommended. PMID:22439081

  20. A Neuroimaging Web Services Interface as a Cyber Physical System for Medical Imaging and Data Management in Brain Research: Design Study

    PubMed Central

    2018-01-01

    Background Structural and functional brain images are essential imaging modalities for medical experts to study brain anatomy. These images are typically visually inspected by experts. To analyze images without any bias, they must be first converted to numeric values. Many software packages are available to process the images, but they are complex and difficult to use. The software packages are also hardware intensive. The results obtained after processing vary depending on the native operating system used and its associated software libraries; data processed in one system cannot typically be combined with data on another system. Objective The aim of this study was to fulfill the neuroimaging community’s need for a common platform to store, process, explore, and visualize their neuroimaging data and results using Neuroimaging Web Services Interface: a series of processing pipelines designed as a cyber physical system for neuroimaging and clinical data in brain research. Methods Neuroimaging Web Services Interface accepts magnetic resonance imaging, positron emission tomography, diffusion tensor imaging, and functional magnetic resonance imaging. These images are processed using existing and custom software packages. The output is then stored as image files, tabulated files, and MySQL tables. The system, made up of a series of interconnected servers, is password-protected and is securely accessible through a Web interface and allows (1) visualization of results and (2) downloading of tabulated data. Results All results were obtained using our processing servers in order to maintain data validity and consistency. The design is responsive and scalable. The processing pipeline started from a FreeSurfer reconstruction of Structural magnetic resonance imaging images. The FreeSurfer and regional standardized uptake value ratio calculations were validated using Alzheimer’s Disease Neuroimaging Initiative input images, and the results were posted at the Laboratory of Neuro Imaging data archive. Notable leading researchers in the field of Alzheimer’s Disease and epilepsy have used the interface to access and process the data and visualize the results. Tabulated results with unique visualization mechanisms help guide more informed diagnosis and expert rating, providing a truly unique multimodal imaging platform that combines magnetic resonance imaging, positron emission tomography, diffusion tensor imaging, and resting state functional magnetic resonance imaging. A quality control component was reinforced through expert visual rating involving at least 2 experts. Conclusions To our knowledge, there is no validated Web-based system offering all the services that Neuroimaging Web Services Interface offers. The intent of Neuroimaging Web Services Interface is to create a tool for clinicians and researchers with keen interest on multimodal neuroimaging. More importantly, Neuroimaging Web Services Interface significantly augments the Alzheimer’s Disease Neuroimaging Initiative data, especially since our data contain a large cohort of Hispanic normal controls and Alzheimer’s Disease patients. The obtained results could be scrutinized visually or through the tabulated forms, informing researchers on subtle changes that characterize the different stages of the disease. PMID:29699962

  1. Robust and fast-converging level set method for side-scan sonar image segmentation

    NASA Astrophysics Data System (ADS)

    Liu, Yan; Li, Qingwu; Huo, Guanying

    2017-11-01

    A robust and fast-converging level set method is proposed for side-scan sonar (SSS) image segmentation. First, the noise in each sonar image is removed using the adaptive nonlinear complex diffusion filter. Second, k-means clustering is used to obtain the initial presegmentation image from the denoised image, and then the distance maps of the initial contours are reinitialized to guarantee the accuracy of the numerical calculation used in the level set evolution. Finally, the satisfactory segmentation is achieved using a robust variational level set model, where the evolution control parameters are generated by the presegmentation. The proposed method is successfully applied to both synthetic image with speckle noise and real SSS images. Experimental results show that the proposed method needs much less iteration and therefore is much faster than the fuzzy local information c-means clustering method, the level set method using a gamma observation model, and the enhanced region-scalable fitting method. Moreover, the proposed method can usually obtain more accurate segmentation results compared with other methods.

  2. Image Registration Algorithm Based on Parallax Constraint and Clustering Analysis

    NASA Astrophysics Data System (ADS)

    Wang, Zhe; Dong, Min; Mu, Xiaomin; Wang, Song

    2018-01-01

    To resolve the problem of slow computation speed and low matching accuracy in image registration, a new image registration algorithm based on parallax constraint and clustering analysis is proposed. Firstly, Harris corner detection algorithm is used to extract the feature points of two images. Secondly, use Normalized Cross Correlation (NCC) function to perform the approximate matching of feature points, and the initial feature pair is obtained. Then, according to the parallax constraint condition, the initial feature pair is preprocessed by K-means clustering algorithm, which is used to remove the feature point pairs with obvious errors in the approximate matching process. Finally, adopt Random Sample Consensus (RANSAC) algorithm to optimize the feature points to obtain the final feature point matching result, and the fast and accurate image registration is realized. The experimental results show that the image registration algorithm proposed in this paper can improve the accuracy of the image matching while ensuring the real-time performance of the algorithm.

  3. Fast single image dehazing based on image fusion

    NASA Astrophysics Data System (ADS)

    Liu, Haibo; Yang, Jie; Wu, Zhengping; Zhang, Qingnian

    2015-01-01

    Images captured in foggy weather conditions often fade the colors and reduce the contrast of the observed objects. An efficient image fusion method is proposed to remove haze from a single input image. First, the initial medium transmission is estimated based on the dark channel prior. Second, the method adopts an assumption that the degradation level affected by haze of each region is the same, which is similar to the Retinex theory, and uses a simple Gaussian filter to get the coarse medium transmission. Then, pixel-level fusion is achieved between the initial medium transmission and coarse medium transmission. The proposed method can recover a high-quality haze-free image based on the physical model, and the complexity of the proposed method is only a linear function of the number of input image pixels. Experimental results demonstrate that the proposed method can allow a very fast implementation and achieve better restoration for visibility and color fidelity compared to some state-of-the-art methods.

  4. Incomplete projection reconstruction of computed tomography based on the modified discrete algebraic reconstruction technique

    NASA Astrophysics Data System (ADS)

    Yang, Fuqiang; Zhang, Dinghua; Huang, Kuidong; Gao, Zongzhao; Yang, YaFei

    2018-02-01

    Based on the discrete algebraic reconstruction technique (DART), this study aims to address and test a new improved algorithm applied to incomplete projection data to generate a high quality reconstruction image by reducing the artifacts and noise in computed tomography. For the incomplete projections, an augmented Lagrangian based on compressed sensing is first used in the initial reconstruction for segmentation of the DART to get higher contrast graphics for boundary and non-boundary pixels. Then, the block matching 3D filtering operator was used to suppress the noise and to improve the gray distribution of the reconstructed image. Finally, simulation studies on the polychromatic spectrum were performed to test the performance of the new algorithm. Study results show a significant improvement in the signal-to-noise ratios (SNRs) and average gradients (AGs) of the images reconstructed from incomplete data. The SNRs and AGs of the new images reconstructed by DART-ALBM were on average 30%-40% and 10% higher than the images reconstructed by DART algorithms. Since the improved DART-ALBM algorithm has a better robustness to limited-view reconstruction, which not only makes the edge of the image clear but also makes the gray distribution of non-boundary pixels better, it has the potential to improve image quality from incomplete projections or sparse projections.

  5. Generation of synthetic CT data using patient specific daily MR image data and image registration

    NASA Astrophysics Data System (ADS)

    Melanie Kraus, Kim; Jäkel, Oliver; Niebuhr, Nina I.; Pfaffenberger, Asja

    2017-02-01

    To fully exploit the advantages of magnetic resonance imaging (MRI) for radiotherapy (RT) treatment planning, a method is required to overcome the problem of lacking electron density information. We aim to establish and evaluate a new method for computed tomography (CT) data generation based on MRI and image registration. The thereby generated CT data is used for dose accumulation. We developed a process flow based on an initial pair of rigidly co-registered CT and T2-weighted MR image representing the same anatomical situation. Deformable image registration using anatomical landmarks is performed between the initial MRI data and daily MR images. The resulting transformation is applied to the initial CT, thus fractional CT data is generated. Furthermore, the dose for a photon intensity modulated RT (IMRT) or intensity modulated proton therapy (IMPT) plan is calculated on the generated fractional CT and accumulated on the initial CT via inverse transformation. The method is evaluated by the use of phantom CT and MRI data. Quantitative validation is performed by evaluation of the mean absolute error (MAE) between the measured and the generated CT. The effect on dose accumulation is examined by means of dose-volume parameters. One patient case is presented to demonstrate the applicability of the method introduced here. Overall, CT data derivation lead to MAEs with a median of 37.0 HU ranging from 29.9 to 66.6 HU for all investigated tissues. The accuracy of image registration showed to be limited in the case of unexpected air cavities and at tissue boundaries. The comparisons of dose distributions based on measured and generated CT data agree well with the published literature. Differences in dose volume parameters kept within 1.6% and 3.2% for photon and proton RT, respectively. The method presented here is particularly suited for application in adaptive RT in current clinical routine, since only minor additional technical equipment is required.

  6. Automated Tracking of Quantitative Assessments of Tumor Burden in Clinical Trials1

    PubMed Central

    Rubin, Daniel L; Willrett, Debra; O'Connor, Martin J; Hage, Cleber; Kurtz, Camille; Moreira, Dilvan A

    2014-01-01

    There are two key challenges hindering effective use of quantitative assessment of imaging in cancer response assessment: 1) Radiologists usually describe the cancer lesions in imaging studies subjectively and sometimes ambiguously, and 2) it is difficult to repurpose imaging data, because lesion measurements are not recorded in a format that permits machine interpretation and interoperability. We have developed a freely available software platform on the basis of open standards, the electronic Physician Annotation Device (ePAD), to tackle these challenges in two ways. First, ePAD facilitates the radiologist in carrying out cancer lesion measurements as part of routine clinical trial image interpretation workflow. Second, ePAD records all image measurements and annotations in a data format that permits repurposing image data for analyses of alternative imaging biomarkers of treatment response. To determine the impact of ePAD on radiologist efficiency in quantitative assessment of imaging studies, a radiologist evaluated computed tomography (CT) imaging studies from 20 subjects having one baseline and three consecutive follow-up imaging studies with and without ePAD. The radiologist made measurements of target lesions in each imaging study using Response Evaluation Criteria in Solid Tumors 1.1 criteria, initially with the aid of ePAD, and then after a 30-day washout period, the exams were reread without ePAD. The mean total time required to review the images and summarize measurements of target lesions was 15% (P < .039) shorter using ePAD than without using this tool. In addition, it was possible to rapidly reanalyze the images to explore lesion cross-sectional area as an alternative imaging biomarker to linear measure. We conclude that ePAD appears promising to potentially improve reader efficiency for quantitative assessment of CT examinations, and it may enable discovery of future novel image-based biomarkers of cancer treatment response. PMID:24772204

  7. Impact of TRMM and SSM/I Rainfall Assimilation on Global Analysis and QPF

    NASA Technical Reports Server (NTRS)

    Hou, Arthur; Zhang, Sara; Reale, Oreste

    2002-01-01

    Evaluation of QPF skills requires quantitatively accurate precipitation analyses. We show that assimilation of surface rain rates derived from the Tropical Rainfall Measuring Mission (TRMM) Microwave Imager and Special Sensor Microwave/Imager (SSM/I) improves quantitative precipitation estimates (QPE) and many aspects of global analyses. Short-range forecasts initialized with analyses with satellite rainfall data generally yield significantly higher QPF threat scores and better storm track predictions. These results were obtained using a variational procedure that minimizes the difference between the observed and model rain rates by correcting the moist physics tendency of the forecast model over a 6h assimilation window. In two case studies of Hurricanes Bonnie and Floyd, synoptic analysis shows that this procedure produces initial conditions with better-defined tropical storm features and stronger precipitation intensity associated with the storm.

  8. The Use of Message Framing to Promote Sexual Risk Reduction in Young Adolescents: A Pilot Exploratory Study

    ERIC Educational Resources Information Center

    Camenga, Deepa R.; Hieftje, Kimberly D.; Fiellin, Lynn E.; Edelman, E. Jennifer; Rosenthal, Marjorie S.; Duncan, Lindsay R.

    2014-01-01

    Few studies have explored the application of message framing to promote health behaviors in adolescents. In this exploratory study, we examined young adolescents' selection of gain- versus loss-framed images and messages when designing an HIV-prevention intervention to promote delayed sexual initiation. Twenty-six adolescents (aged 10-14 years)…

  9. Neuroimaging and Fetal Alcohol Spectrum Disorders

    ERIC Educational Resources Information Center

    Norman, Andria L.; Crocker, Nicole; Mattson, Sarah N.; Riley, Edward P.

    2009-01-01

    The detrimental effects of prenatal alcohol exposure on the developing brain include structural brain anomalies as well as cognitive and behavioral deficits. Initial neuroimaging studies of fetal alcohol spectrum disorders (FASD) using magnetic resonance imaging (MRI) confirmed previous autopsy reports of overall reduction in brain volume and…

  10. The Multifaceted Uses and Therapeutic Advantages of Nanoparticles for Atherosclerosis Research.

    PubMed

    DiStasio, Nicholas; Lehoux, Stephanie; Khademhosseini, Ali; Tabrizian, Maryam

    2018-05-08

    Nanoparticles are uniquely suited for the study and development of potential therapies against atherosclerosis by virtue of their size, fine-tunable properties, and ability to incorporate therapies and/or imaging modalities. Furthermore, nanoparticles can be specifically targeted to the atherosclerotic plaque, evading off-target effects and/or associated cytotoxicity. There has been a wealth of knowledge available concerning the use of nanotechnologies in cardiovascular disease and atherosclerosis, in particular in animal models, but with a major focus on imaging agents. In fact, roughly 60% of articles from an initial search for this review included examples of imaging applications of nanoparticles. Thus, this review focuses on experimental therapy interventions applied to and observed in animal models. Particular emphasis is placed on how nanoparticle materials and properties allow researchers to learn a great deal about atherosclerosis. The objective of this review was to provide an update for nanoparticle use in imaging and drug delivery studies and to illustrate how nanoparticles can be used for sensing and modelling, for studying fundamental biological mechanisms, and for the delivery of biotherapeutics such as proteins, peptides, nucleic acids, and even cells all with the goal of attenuating atherosclerosis. Furthermore, the various atherosclerosis processes targeted mainly for imaging studies have been summarized in the hopes of inspiring new and exciting targeted therapeutic and/or imaging strategies.

  11. Spatial Analysis to Determine Paddy Field Changes in Indonesia: A Case Study in Suburban Areas of Jakarta

    NASA Astrophysics Data System (ADS)

    Putri Utami, Nadia; Ahamed, Tofael

    2018-05-01

    Karawang, a suburban area of Greater Jakarta, is known as the second largest rice-producing region in West Java, Indonesia. However, expansion of urban sprawl and industrial area from Greater Jakarta have created rapid agricultural land use/cover changes, especially paddy field, in Karawang. This study analyzed the land use/cover changes of paddy field from 2000 to 2016. Landsat 4-5 TM and Landsat 8 OLI/TIRS images were acquired from USGS Earth Explorer, UTM zone 48 south. Satellite image pre-processing, ground truth data collection, supervised maximum likelihood classifications, and Post-Classification Comparison (PCC) were performed in ArcGIS 10.3®. It was observed between 2000 and 2016, urban area increased 4.46% (8530 ha) from initial area of 10,004 ha. Meanwhile paddy field decreased 3.18% (6091 ha) from initial area of 115,720 ha. The spatial analysis showed that paddy field in the fringe of urban area are more susceptible for changes.

  12. Emergence of dominant initiation sites for interictal spikes in rat neocortex

    PubMed Central

    Vitantonio, Daniel; Xu, Weifeng; Geng, Xinling; Wolff, Brian S.; Takagaki, Kentaroh; Motamedi, Gholam K.

    2015-01-01

    Neuronal populations with unbalanced inhibition can generate interictal spikes (ISs), where each IS starts from a small initiation site and then spreads activation across a larger area. We used in vivo voltage-sensitive dye imaging to map the initiation site of ISs in rat visual cortex disinhibited by epidural application of bicuculline methiodide. Immediately after the application of bicuculline, the IS initiation sites were widely distributed over the entire disinhibited area. After ∼10 min, a small number of sites became “dominant” and initiated the majority of the ISs throughout the course of imaging. Such domination also occurred in cortical slices, which lack long-range connections between the cortex and subcortical structures. This domination of IS initiation sites may allow timing-related plasticity mechanisms to provide a spatial organization where connections projecting outward from the dominant initiation site become strengthened. Understanding the spatiotemporal organization of IS initiation sites may contribute to our understanding of epileptogenesis in its very early stages, because a dominant IS initiation site with strengthened outward connectivity may ultimately develop into a seizure focus. PMID:26445866

  13. Assessment of fresh breast tissue specimens with confocal strip-mosaicking microscopy in an emulated pathology setting (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Abeytunge, Sanjeewa; Larson, Bjorg A.; Peterson, Gary; Rajadhyaksha, Milind; Murray, Melissa

    2017-02-01

    Confocal microscopy is in clinical use to diagnose skin cancers in the United States and in Europe. Potentially, this technology may provide bed-side pathology in breast cancer surgery during tumor removal. Initial studies have described major findings of invasive breast cancers as seen on fluorescence confocal microscopy. In many of these studies the region of interest (ROI) used in the analysis was user-selected and small (typically 15 square-mm). Although these important findings open exploration into rapid pathology, further development and implementation in a surgical setting will require examination of large specimens in a blinded fashion that will address the needs of typical surgical settings. In post surgery pathology viewing, pathologists inspect the entire pathology section with a low (2X) magnification objective lens initially and then zoomed in to ROIs with higher magnification lenses (10X to 40X) magnifications to further investigate suspected regions. In this study we explore the possibility of implementation in a typical surgical setting with a new microscope, termed confocal strip-mosaicking microscope (CSM microscope), which images an area of 400 square-mm (2 cm x 2 cm) of tissue with cellular level resolution in 10 minutes. CSM images of 34 human breast tissue specimens from 18 patients were blindly analyzed by a board-certified pathologist and correlated with the corresponding standard fixed histopathology. Invasive tumors and benign tissue were clearly identified in CSM images. Thirty specimens were concordant for images-to-histopathology correlation while four were discordant. Preliminary results from on-going work to molecularly target tumor margin will also be presented.

  14. From nociception to pain perception: imaging the spinal and supraspinal pathways

    PubMed Central

    Brooks, Jonathan; Tracey, Irene

    2005-01-01

    Functional imaging techniques have allowed researchers to look within the brain, and revealed the cortical representation of pain. Initial experiments, performed in the early 1990s, revolutionized pain research, as they demonstrated that pain was not processed in a single cortical area, but in several distributed brain regions. Over the last decade, the roles of these pain centres have been investigated and a clearer picture has emerged of the medial and lateral pain system. In this brief article, we review the imaging literature to date that has allowed these advances to be made, and examine the new frontiers for pain imaging research: imaging the brainstem and other structures involved in the descending control of pain; functional and anatomical connectivity studies of pain processing brain regions; imaging models of neuropathic pain-like states; and going beyond the brain to image spinal function. The ultimate goal of such research is to take these new techniques into the clinic, to investigate and provide new remedies for chronic pain sufferers. PMID:16011543

  15. Considering an Affect Regulation Framework for Examining the Association Between Body Dissatisfaction and Positive Body Image in Black Older Adolescent Females: Does Body Mass Index Matter?

    PubMed Central

    Butler-Ajibade, Phoebe; Robinson, Seronda A.

    2014-01-01

    The present study provided an initial evaluation of an affect regulation model describing the association between body dissatisfaction and two contemporary measures of positive body image among 247 Black college-bound older adolescent females. We further tested whether possessing a higher body mass index (BMI) would strengthen these associations. Self-reported height and weight were used to calculate BMI. Respondents also completed a culturally-sensitive figure rating scale along with assessments of body appreciation and body image flexibility. Results indicated a robust positive association between the two measures of positive body image; BMI was the strongest predictor of both body appreciation and body image flexibility with body size discrepancy (current minus ideal) contributing incremental variance to both models tested. Implications for improving our understanding of the association between positive and negative body image and bolstering positive body image to promote health-protective behaviors among Black young women at this developmental juncture are discussed. PMID:25079011

  16. The image of mathematics held by Irish post-primary students

    NASA Astrophysics Data System (ADS)

    Lane, Ciara; Stynes, Martin; O'Donoghue, John

    2014-08-01

    The image of mathematics held by Irish post-primary students was examined and a model for the image found was constructed. Initially, a definition for 'image of mathematics' was adopted with image of mathematics hypothesized as comprising attitudes, beliefs, self-concept, motivation, emotions and past experiences of mathematics. Research focused on students studying ordinary level mathematics for the Irish Leaving Certificate examination - the final examination for students in second-level or post-primary education. Students were aged between 15 and 18 years. A questionnaire was constructed with both quantitative and qualitative aspects. The questionnaire survey was completed by 356 post-primary students. Responses were analysed quantitatively using Statistical Package for the Social Sciences (SPSS) and qualitatively using the constant comparative method of analysis and by reviewing individual responses. Findings provide an insight into Irish post-primary students' images of mathematics and offer a means for constructing a theoretical model of image of mathematics which could be beneficial for future research.

  17. An Image Encryption Algorithm Utilizing Julia Sets and Hilbert Curves

    PubMed Central

    Sun, Yuanyuan; Chen, Lina; Xu, Rudan; Kong, Ruiqing

    2014-01-01

    Image encryption is an important and effective technique to protect image security. In this paper, a novel image encryption algorithm combining Julia sets and Hilbert curves is proposed. The algorithm utilizes Julia sets’ parameters to generate a random sequence as the initial keys and gets the final encryption keys by scrambling the initial keys through the Hilbert curve. The final cipher image is obtained by modulo arithmetic and diffuse operation. In this method, it needs only a few parameters for the key generation, which greatly reduces the storage space. Moreover, because of the Julia sets’ properties, such as infiniteness and chaotic characteristics, the keys have high sensitivity even to a tiny perturbation. The experimental results indicate that the algorithm has large key space, good statistical property, high sensitivity for the keys, and effective resistance to the chosen-plaintext attack. PMID:24404181

  18. Research on marine and freshwater fish identification model based on hyper-spectral imaging technology

    NASA Astrophysics Data System (ADS)

    Fu, Yan; Guo, Pei-yuan; Xiang, Ling-zi; Bao, Man; Chen, Xing-hai

    2013-08-01

    With the gradually mature of hyper spectral image technology, the application of the meat nondestructive detection and recognition has become one of the current research focuses. This paper for the study of marine and freshwater fish by the pre-processing and feature extraction of the collected spectral curve data, combined with BP network structure and LVQ network structure, a predictive model of hyper spectral image data of marine and freshwater fish has been initially established and finally realized the qualitative analysis and identification of marine and freshwater fish quality. The results of this study show that hyper spectral imaging technology combined with the BP and LVQ Artificial Neural Network Model can be used for the identification of marine and freshwater fish detection. Hyper-spectral data acquisition can be carried out without any pretreatment of the samples, thus hyper-spectral imaging technique is the lossless, high- accuracy and rapid detection method for quality of fish. In this study, only 30 samples are used for the exploratory qualitative identification of research, although the ideal study results are achieved, we will further increase the sample capacity to take the analysis of quantitative identification and verify the feasibility of this theory.

  19. Automated segmentation of murine lung tumors in x-ray micro-CT images

    NASA Astrophysics Data System (ADS)

    Swee, Joshua K. Y.; Sheridan, Clare; de Bruin, Elza; Downward, Julian; Lassailly, Francois; Pizarro, Luis

    2014-03-01

    Recent years have seen micro-CT emerge as a means of providing imaging analysis in pre-clinical study, with in-vivo micro-CT having been shown to be particularly applicable to the examination of murine lung tumors. Despite this, existing studies have involved substantial human intervention during the image analysis process, with the use of fully-automated aids found to be almost non-existent. We present a new approach to automate the segmentation of murine lung tumors designed specifically for in-vivo micro-CT-based pre-clinical lung cancer studies that addresses the specific requirements of such study, as well as the limitations human-centric segmentation approaches experience when applied to such micro-CT data. Our approach consists of three distinct stages, and begins by utilizing edge enhancing and vessel enhancing non-linear anisotropic diffusion filters to extract anatomy masks (lung/vessel structure) in a pre-processing stage. Initial candidate detection is then performed through ROI reduction utilizing obtained masks and a two-step automated segmentation approach that aims to extract all disconnected objects within the ROI, and consists of Otsu thresholding, mathematical morphology and marker-driven watershed. False positive reduction is finally performed on initial candidates through random-forest-driven classification using the shape, intensity, and spatial features of candidates. We provide validation of our approach using data from an associated lung cancer study, showing favorable results both in terms of detection (sensitivity=86%, specificity=89%) and structural recovery (Dice Similarity=0.88) when compared against manual specialist annotation.

  20. Laser speckle contrast imaging of cerebral autoregulation in rats at a macro- and microcirculation level

    NASA Astrophysics Data System (ADS)

    Semyachkina-Glushkovskaya, O. V.; Abdurashitov, A. S.; Sindeev, S. S.; Tuchin, V. V.

    2016-06-01

    Using the method of laser speckle imaging for the simultaneous study of macro- and microcirculation in cerebral vessels of healthy rats, we show that the mechanisms underlying cerebral autoregulation depend on the initial condition of the organism and the sex of individual animals. The pharmacological dose-dependent stimulation of the peripheral arterial pressure increase is not accompanied by the cerebral circulation responses of analogous intensity, but manifests itself as 'compensating' reactions, namely, the redistribution of the blood flow at the level of macro- (in females) and microcirculation (in females and males). The obtained results extend our understanding of the capabilities of laser speckle imaging technique in neurophysiological studies of reserve abilities of cerebral circulation autoregulation under the conditions of hypertensive status formation.

  1. The Effect Of Pixel Size On The Detection Rate Of Early Pulmonary Sarcoidosis In Digital Chest Radiographic Systems

    NASA Astrophysics Data System (ADS)

    MacMahon, Heber; Vyborny, Carl; Powell, Gregory; Doi, Kunio; Metz, Charles E.

    1984-08-01

    In digital radiography the pixel size used determines the potential spatial resolution of the system. The need for spatial resolution varies depending on the subject matter imaged. In many areas, including the chest, the minimum spatial resolution requirements have not been determined. Sarcoidosis is a disease which frequently causes subtle interstitial infiltrates in the lungs. As the initial step in an investigation designed to determine the minimum pixel size required in digital chest radiographic systems, we have studied 1 mm pixel digitized images on patients with early pulmonary sarcoidosis. The results of this preliminary study suggest that neither mild interstitial pulmonary infiltrates nor other abnormalities such as pneumothoraces may be detected reliably with 1 mm pixel digital images.

  2. Automatic vasculature identification in coronary angiograms by adaptive geometrical tracking.

    PubMed

    Xiao, Ruoxiu; Yang, Jian; Goyal, Mahima; Liu, Yue; Wang, Yongtian

    2013-01-01

    As the uneven distribution of contrast agents and the perspective projection principle of X-ray, the vasculatures in angiographic image are with low contrast and are generally superposed with other organic tissues; therefore, it is very difficult to identify the vasculature and quantitatively estimate the blood flow directly from angiographic images. In this paper, we propose a fully automatic algorithm named adaptive geometrical vessel tracking (AGVT) for coronary artery identification in X-ray angiograms. Initially, the ridge enhancement (RE) image is obtained utilizing multiscale Hessian information. Then, automatic initialization procedures including seed points detection, and initial directions determination are performed on the RE image. The extracted ridge points can be adjusted to the geometrical centerline points adaptively through diameter estimation. Bifurcations are identified by discriminating connecting relationship of the tracked ridge points. Finally, all the tracked centerlines are merged and smoothed by classifying the connecting components on the vascular structures. Synthetic angiographic images and clinical angiograms are used to evaluate the performance of the proposed algorithm. The proposed algorithm is compared with other two vascular tracking techniques in terms of the efficiency and accuracy, which demonstrate successful applications of the proposed segmentation and extraction scheme in vasculature identification.

  3. Space vehicle approach velocity judgments under simulated visual space conditions

    NASA Technical Reports Server (NTRS)

    Haines, Richard F.

    1987-01-01

    Thirty-five volunteers responded when they first perceived an increase in apparent size of a collimated, 2-D image of an Orbiter vehicle. The test variables of interest included the presence of a fixed angular reticle within the field of view (FOV); three initial Orbiter distances; three constant Orbiter approach velocities corresponding to 1.6, 0.8, and 0.4 percent of the initial distance per second; and two background starfield velocities. It was found that: (1) at each initial range, increasing approach velocity led to a larger distance between the eye and Orbiter image at threshold; (2) including the fixed reticle in the FOV produced a smaller distance between the eye and Orbiter image at threshold; and (3) increasing background star velocity during this judgment led to a smaller distance between the eye and Orbiter image at threshold. The last two findings suggest that other detail within the FOV may compete for available attention which otherwise would be available for judging image expansion; thus, the target has to approach the observer nearer than otherwise if these details were present. These findings are discussed in relation to previous research and possible underlying mechanisms.

  4. Interferometric Imaging Directly with Closure Phases and Closure Amplitudes

    NASA Astrophysics Data System (ADS)

    Chael, Andrew A.; Johnson, Michael D.; Bouman, Katherine L.; Blackburn, Lindy L.; Akiyama, Kazunori; Narayan, Ramesh

    2018-04-01

    Interferometric imaging now achieves angular resolutions as fine as ∼10 μas, probing scales that are inaccessible to single telescopes. Traditional synthesis imaging methods require calibrated visibilities; however, interferometric calibration is challenging, especially at high frequencies. Nevertheless, most studies present only a single image of their data after a process of “self-calibration,” an iterative procedure where the initial image and calibration assumptions can significantly influence the final image. We present a method for efficient interferometric imaging directly using only closure amplitudes and closure phases, which are immune to station-based calibration errors. Closure-only imaging provides results that are as noncommittal as possible and allows for reconstructing an image independently from separate amplitude and phase self-calibration. While closure-only imaging eliminates some image information (e.g., the total image flux density and the image centroid), this information can be recovered through a small number of additional constraints. We demonstrate that closure-only imaging can produce high-fidelity results, even for sparse arrays such as the Event Horizon Telescope, and that the resulting images are independent of the level of systematic amplitude error. We apply closure imaging to VLBA and ALMA data and show that it is capable of matching or exceeding the performance of traditional self-calibration and CLEAN for these data sets.

  5. High-current, relativistic electron-beam transport in metals and the role of magnetic collimation.

    PubMed

    Storm, M; Solodov, A A; Myatt, J F; Meyerhofer, D D; Stoeckl, C; Mileham, C; Betti, R; Nilson, P M; Sangster, T C; Theobald, W; Guo, Chunlei

    2009-06-12

    High-resolution coherent transition radiation (CTR) imaging diagnoses electrons accelerated in laser-solid interactions with intensities of approximately 10;{19} W/cm;{2}. The CTR images indicate electron-beam filamentation and annular propagation. The beam temperature and half-angle divergence are inferred to be approximately 1.4 MeV and approximately 16 degrees , respectively. Three-dimensional hybrid-particle-in-cell code simulations reproduce the details of the CTR images assuming an initial half-angle divergence of approximately 56 degrees . Self-generated resistive magnetic fields are responsible for the difference between the initial and measured divergence.

  6. Initial Results from Fitting Resolved Modes using HMI Intensity Observations

    NASA Astrophysics Data System (ADS)

    Korzennik, Sylvain G.

    2017-08-01

    The HMI project recently started processing the continuum intensity images following global helioseismology procedures similar to those used to process the velocity images. The spatial decomposition of these images has produced time series of spherical harmonic coefficients for degrees up to l=300, using a different apodization than the one used for velocity observations. The first 360 days of observations were processed and made available. I present initial results from fitting these time series using my state of the art fitting methodology and compare the derived mode characteristics to those estimated using co-eval velocity observations.

  7. A retrospective analysis of negative diffusion-weighted image results in patients with acute cerebral infarction

    PubMed Central

    Zuo, Lian; Zhang, Yue; Xu, Xiahong; Li, Ying; Bao, Huan; Hao, Junjie; Wang, Xin; Li, Gang

    2015-01-01

    We aimed to investigate the clinicoradiologic determinants of negative diffusion-weighted image (DWI) results in patients with acute cerebral infarction (ACI). The medical records were reviewed of ACI patients. Patients were divided to the DWI positive and negative group. Positive DWI was used as independent variable and patients' clinicoradiologic factors were used as co-variables for multivariate logistic regression analysis. 349 patients received initial cerebral MRI within 72 hours of admission. Lacunar infarction was most common (42.1%) followed by posterior circulation infarction (30.1%) and partial anterior circulation infarction (18.1%). The majority of the patients (72.2%) had an NIHSS score of less than 5 at admission. 316 patients (90.54%) were positive on initial DWI. Patients with smoking, initial SBP ≥ 140 or DBP ≥ 90 mmHg, initial fasting plasma glucose (FPG) ≥7.0 mmol/L, initial MRI from onset of disease >1 d and anterior circulation infarction were liable to show positive DWI. Furthermore, DWI negative patients had significantly lower NIHSS scores (IQR 0,1,2) than DWI positive patients (IQR 1,2,4) (P = 0.000) at two weeks post onset of acute cerebral infarction. In conclusion, multiple clinicoradiologic factors are associated with negative and positive DWI and further delineation of these factors is required in future prospective studies. PMID:25777182

  8. Segmentation of optic disc and optic cup in retinal fundus images using shape regression.

    PubMed

    Sedai, Suman; Roy, Pallab K; Mahapatra, Dwarikanath; Garnavi, Rahil

    2016-08-01

    Glaucoma is one of the leading cause of blindness. The manual examination of optic cup and disc is a standard procedure used for detecting glaucoma. This paper presents a fully automatic regression based method which accurately segments optic cup and disc in retinal colour fundus image. First, we roughly segment optic disc using circular hough transform. The approximated optic disc is then used to compute the initial optic disc and cup shapes. We propose a robust and efficient cascaded shape regression method which iteratively learns the final shape of the optic cup and disc from a given initial shape. Gradient boosted regression trees are employed to learn each regressor in the cascade. A novel data augmentation approach is proposed to improve the regressors performance by generating synthetic training data. The proposed optic cup and disc segmentation method is applied on an image set of 50 patients and demonstrate high segmentation accuracy for optic cup and disc with dice metric of 0.95 and 0.85 respectively. Comparative study shows that our proposed method outperforms state of the art optic cup and disc segmentation methods.

  9. Ground Truth Studies - A hands-on environmental science program for students, grades K-12

    NASA Technical Reports Server (NTRS)

    Katzenberger, John; Chappell, Charles R.

    1992-01-01

    The paper discusses the background and the objectives of the Ground Truth Studies (GTSs), an activity-based teaching program which integrates local environmental studies with global change topics, utilizing remotely sensed earth imagery. Special attention is given to the five key concepts around which the GTS programs are organized, the pilot program, the initial pilot study evaluation, and the GTS Handbook. The GTS Handbook contains a primer on global change and remote sensing, aerial and satellite images, student activities, glossary, and an appendix of reference material. Also described is a K-12 teacher training model. International participation in the program is to be initiated during the 1992-1993 school year.

  10. Intra- and inter-observer reliability of quantitative analysis of the infra-patellar fat pad and comparison between fat- and non-fat-suppressed imaging—Data from the osteoarthritis initiative

    PubMed Central

    Steidle-Kloc, E.; Wirth, W.; Ruhdorfer, A.; Dannhauer, T.; Eckstein, F.

    2015-01-01

    The infra-patellar fat pad (IPFP), as intra-articular adipose tissue represents a potential source of pro-inflammatory cytokines and its size has been suggested to be associated with osteoarthritis (OA) of the knee. This study examines inter- and intra-observer reliability of fat-suppressed (fs) and non-fat-suppressed (nfs) MR imaging for determination of IPFP morphological measurements as novel biomarkers. The IPFP of nine right knees of healthy Osteoarthritis Initiative participants was segmented by five readers, using fs and nfs baseline sagittal MRIs. The intra-observer reliability was determined from baseline and 1-year follow-up images. All segmentations were quality controlled (QC) by an expert reader. Reliability was expressed as root mean square coefficient of variation (RMS CV%). After QC, the inter-observer reliability for fs (nfs) imaging was 2.0% (1.1%) for IPFP volume, 2.1%/2.5% (1.6%/1.8%) for anterior/posterior surface areas, 1.8% (1.8%) for depth, and 2.1% (2.4%) for maximum sagittal area. The intra-observer reliability was 3.1% (5.0%) for volume, 2.3%/2.8% (2.5%/2.9%) for anterior/posterior surfaces, 1.9% (3.5%) for depth, and 3.3% (4.5%) for maximum sagittal area. IPFP volume from nfs images was systematically greater (+7.3%) than from fs images, but highly correlated (r = 0.98). The results suggest that quantitative measurements of IPFP morphology can be performed with satisfactory reliability when expert QC is implemented. The IPFP is more clearly depicted in nfs images, and there is a small systematic off-set versus analysis from fs images. However, the high linear relationship between fs and nfs imaging suggests that fs images can be used to analyze IPFP morphology, when nfs images are not available. PMID:26569532

  11. Transformational Leadership & Professional Development for Digitally Rich Learning Environments: A Case Study of the Galileo Educational Network.

    ERIC Educational Resources Information Center

    Jacobsen, Michele; Clifford, Pat; Friesen, Sharon

    The Galileo Educational Network is an innovative educational reform initiative that brings learning to learners. Expert teachers work alongside teachers and students in schools to create new images of engaged learning, technology integration and professional development. This case study is based on the nine schools involved with Galileo in…

  12. The Use of Ultrasound in Remediation of North American English /r/ in 2 Adolescents

    ERIC Educational Resources Information Center

    Adler-Bock, Marcy; Bernhardt, Barbara May; Gick, Bryan; Bacsfalvi, Penelope

    2007-01-01

    Purpose: Ultrasound can provide images of the tongue during speech production. The present study set out to examine the potential utility of ultrasound in remediation of North American English /r/. Method: The participants were 2 Canadian English-speaking adolescents who had not yet acquired /r/. The study included an initial period without…

  13. MedXViewer: an extensible web-enabled software package for medical imaging

    NASA Astrophysics Data System (ADS)

    Looney, P. T.; Young, K. C.; Mackenzie, Alistair; Halling-Brown, Mark D.

    2014-03-01

    MedXViewer (Medical eXtensible Viewer) is an application designed to allow workstation-independent, PACS-less viewing and interaction with anonymised medical images (e.g. observer studies). The application was initially implemented for use in digital mammography and tomosynthesis but the flexible software design allows it to be easily extended to other imaging modalities. Regions of interest can be identified by a user and any associated information about a mark, an image or a study can be added. The questions and settings can be easily configured depending on the need of the research allowing both ROC and FROC studies to be performed. The extensible nature of the design allows for other functionality and hanging protocols to be available for each study. Panning, windowing, zooming and moving through slices are all available while modality-specific features can be easily enabled e.g. quadrant zooming in mammographic studies. MedXViewer can integrate with a web-based image database allowing results and images to be stored centrally. The software and images can be downloaded remotely from this centralised data-store. Alternatively, the software can run without a network connection where the images and results can be encrypted and stored locally on a machine or external drive. Due to the advanced workstation-style functionality, the simple deployment on heterogeneous systems over the internet without a requirement for administrative access and the ability to utilise a centralised database, MedXViewer has been used for running remote paper-less observer studies and is capable of providing a training infrastructure and co-ordinating remote collaborative viewing sessions (e.g. cancer reviews, interesting cases).

  14. Initial clinical results with a new needle screen storage phosphor system in chest radiograms.

    PubMed

    Körner, M; Wirth, S; Treitl, M; Reiser, M; Pfeifer, K-J

    2005-11-01

    To evaluate image quality and anatomical detail depiction in dose-reduced digital plain chest radiograms using a new needle screen storage phosphor (NIP) in comparison to full dose conventional powder screen storage phosphor (PIP) images. 24 supine chest radiograms were obtained with PIP at standard dose and compared to follow-up studies of the same patients obtained with NIP with dose reduced to 50 % of the PIP dose (all imaging systems: AGFA-Gevaert, Mortsel, Belgium). In both systems identical versions of post-processing software supplied by the manufacturer were used with matched parameters. Six independent readers blinded to both modality and dose evaluated the images for depiction and differentiation of defined anatomical regions (peripheral lung parenchyma, central lung parenchyma, hilum, heart, diaphragm, upper mediastinum, and bone). All NIP images were compared to the corresponding PIP images using a five-point scale (- 2, clearly inferior to + 2, clearly superior). Overall image quality was rated for each PIP and NIP image separately (1, not usable to 5, excellent). PIP and dose reduced NIP images were rated equivalent. Mean image noise impression was only slightly higher on NIP images. Mean image quality for NIP showed no significant differences (p > 0.05, Mann-Whitney U test). With the use of the new needle structured storage phosphors in chest radiography, dose reduction of up to 50 % is possible without detracting from image quality or detail depiction. Especially in patients with multiple follow-up studies the overall dose can be decreased significantly.

  15. Definitions for a common standard for 2D speckle tracking echocardiography: consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging.

    PubMed

    Voigt, Jens-Uwe; Pedrizzetti, Gianni; Lysyansky, Peter; Marwick, Tom H; Houle, Hélène; Baumann, Rolf; Pedri, Stefano; Ito, Yasuhiro; Abe, Yasuhiko; Metz, Stephen; Song, Joo Hyun; Hamilton, Jamie; Sengupta, Partho P; Kolias, Theodore J; d'Hooge, Jan; Aurigemma, Gerard P; Thomas, James D; Badano, Luigi Paolo

    2015-02-01

    Recognizing the critical need for standardization in strain imaging, in 2010, the European Association of Echocardiography (now the European Association of Cardiovascular Imaging, EACVI) and the American Society of Echocardiography (ASE) invited technical representatives from all interested vendors to participate in a concerted effort to reduce intervendor variability of strain measurement. As an initial product of the work of the EACVI/ASE/Industry initiative to standardize deformation imaging, we prepared this technical document which is intended to provide definitions, names, abbreviations, formulas, and procedures for calculation of physical quantities derived from speckle tracking echocardiography and thus create a common standard. Copyright © 2015 American Society of Echocardiography. All rights reserved.

  16. Stop-Frame Filming and Discovery of Reactions at the Single-Molecule Level by Transmission Electron Microscopy

    PubMed Central

    2017-01-01

    We report an approach, named chemTEM, to follow chemical transformations at the single-molecule level with the electron beam of a transmission electron microscope (TEM) applied as both a tunable source of energy and a sub-angstrom imaging probe. Deposited on graphene, disk-shaped perchlorocoronene molecules are precluded from intermolecular interactions. This allows monomolecular transformations to be studied at the single-molecule level in real time and reveals chlorine elimination and reactive aryne formation as a key initial stage of multistep reactions initiated by the 80 keV e-beam. Under the same conditions, perchlorocoronene confined within a nanotube cavity, where the molecules are situated in very close proximity to each other, enables imaging of intermolecular reactions, starting with the Diels–Alder cycloaddition of a generated aryne, followed by rearrangement of the angular adduct to a planar polyaromatic structure and the formation of a perchlorinated zigzag nanoribbon of graphene as the final product. ChemTEM enables the entire process of polycondensation, including the formation of metastable intermediates, to be captured in a one-shot “movie”. A molecule with a similar size and shape but with a different chemical composition, octathio[8]circulene, under the same conditions undergoes another type of polycondensation via thiyl biradical generation and subsequent reaction leading to polythiophene nanoribbons with irregular edges incorporating bridging sulfur atoms. Graphene or carbon nanotubes supporting the individual molecules during chemTEM studies ensure that the elastic interactions of the molecules with the e-beam are the dominant forces that initiate and drive the reactions we image. Our ab initio DFT calculations explicitly incorporating the e-beam in the theoretical model correlate with the chemTEM observations and give a mechanism for direct control not only of the type of the reaction but also of the reaction rate. Selection of the appropriate e-beam energy and control of the dose rate in chemTEM enabled imaging of reactions on a time frame commensurate with TEM image capture rates, revealing atomistic mechanisms of previously unknown processes. PMID:28191929

  17. Non-invasive optical estimate of tissue composition to differentiate malignant from benign breast lesions: A pilot study

    NASA Astrophysics Data System (ADS)

    Taroni, Paola; Paganoni, Anna Maria; Ieva, Francesca; Pifferi, Antonio; Quarto, Giovanna; Abbate, Francesca; Cassano, Enrico; Cubeddu, Rinaldo

    2017-01-01

    Several techniques are being investigated as a complement to screening mammography, to reduce its false-positive rate, but results are still insufficient to draw conclusions. This initial study explores time domain diffuse optical imaging as an adjunct method to classify non-invasively malignant vs benign breast lesions. We estimated differences in tissue composition (oxy- and deoxyhemoglobin, lipid, water, collagen) and absorption properties between lesion and average healthy tissue in the same breast applying a perturbative approach to optical images collected at 7 red-near infrared wavelengths (635-1060 nm) from subjects bearing breast lesions. The Discrete AdaBoost procedure, a machine-learning algorithm, was then exploited to classify lesions based on optically derived information (either tissue composition or absorption) and risk factors obtained from patient’s anamnesis (age, body mass index, familiarity, parity, use of oral contraceptives, and use of Tamoxifen). Collagen content, in particular, turned out to be the most important parameter for discrimination. Based on the initial results of this study the proposed method deserves further investigation.

  18. Vortex ring formation at the open end of a shock tube: A particle image velocimetry study

    NASA Astrophysics Data System (ADS)

    Arakeri, J. H.; Das, D.; Krothapalli, A.; Lourenco, L.

    2004-04-01

    The vortex ring generated subsequent to the diffraction of a shock wave from the open end of a shock tube is studied using particle image velocimetry. We examine the early evolution of the compressible vortex ring for three-exit shock Mach numbers, 1.1, 1.2, and 1.3. For the three cases studied, the ring formation is complete at about tUb/D=2, where t is time, Ub is fluid velocity behind shock as it exits the tube and D is tube diameter. Unlike in the case of piston generated incompressible vortex rings where the piston velocity variation with time is usually trapezoidal, in the shock-generated vortex ring case the exit fluid velocity doubles from its initial value Ub before it slowly decays to zero. At the end of the ring formation, its translation speed is observed to be about 0.7 Ub. During initial formation and propagation, a jet-like flow exists behind the vortex ring. The vortex ring detachment from the tailing jet, commonly referred to as pinch-off, is briefly discussed.

  19. Semi-automated Image Processing for Preclinical Bioluminescent Imaging.

    PubMed

    Slavine, Nikolai V; McColl, Roderick W

    Bioluminescent imaging is a valuable noninvasive technique for investigating tumor dynamics and specific biological molecular events in living animals to better understand the effects of human disease in animal models. The purpose of this study was to develop and test a strategy behind automated methods for bioluminescence image processing from the data acquisition to obtaining 3D images. In order to optimize this procedure a semi-automated image processing approach with multi-modality image handling environment was developed. To identify a bioluminescent source location and strength we used the light flux detected on the surface of the imaged object by CCD cameras. For phantom calibration tests and object surface reconstruction we used MLEM algorithm. For internal bioluminescent sources we used the diffusion approximation with balancing the internal and external intensities on the boundary of the media and then determined an initial order approximation for the photon fluence we subsequently applied a novel iterative deconvolution method to obtain the final reconstruction result. We find that the reconstruction techniques successfully used the depth-dependent light transport approach and semi-automated image processing to provide a realistic 3D model of the lung tumor. Our image processing software can optimize and decrease the time of the volumetric imaging and quantitative assessment. The data obtained from light phantom and lung mouse tumor images demonstrate the utility of the image reconstruction algorithms and semi-automated approach for bioluminescent image processing procedure. We suggest that the developed image processing approach can be applied to preclinical imaging studies: characteristics of tumor growth, identify metastases, and potentially determine the effectiveness of cancer treatment.

  20. A model-based approach for detection of runways and other objects in image sequences acquired using an on-board camera

    NASA Technical Reports Server (NTRS)

    Kasturi, Rangachar; Devadiga, Sadashiva; Tang, Yuan-Liang

    1994-01-01

    This research was initiated as a part of the Advanced Sensor and Imaging System Technology (ASSIST) program at NASA Langley Research Center. The primary goal of this research is the development of image analysis algorithms for the detection of runways and other objects using an on-board camera. Initial effort was concentrated on images acquired using a passive millimeter wave (PMMW) sensor. The images obtained using PMMW sensors under poor visibility conditions due to atmospheric fog are characterized by very low spatial resolution but good image contrast compared to those images obtained using sensors operating in the visible spectrum. Algorithms developed for analyzing these images using a model of the runway and other objects are described in Part 1 of this report. Experimental verification of these algorithms was limited to a sequence of images simulated from a single frame of PMMW image. Subsequent development and evaluation of algorithms was done using video image sequences. These images have better spatial and temporal resolution compared to PMMW images. Algorithms for reliable recognition of runways and accurate estimation of spatial position of stationary objects on the ground have been developed and evaluated using several image sequences. These algorithms are described in Part 2 of this report. A list of all publications resulting from this work is also included.

  1. Automatic image registration performance for two different CBCT systems; variation with imaging dose

    NASA Astrophysics Data System (ADS)

    Barber, J.; Sykes, J. R.; Holloway, L.; Thwaites, D. I.

    2014-03-01

    The performance of an automatic image registration algorithm was compared on image sets collected with two commercial CBCT systems, and the relationship with imaging dose was explored. CBCT images of a CIRS Virtually Human Male Pelvis phantom (VHMP) were collected on Varian TrueBeam/OBI and Elekta Synergy/XVI linear accelerators, across a range of mAs settings. Each CBCT image was registered 100 times, with random initial offsets introduced. Image registration was performed using the grey value correlation ratio algorithm in the Elekta XVI software, to a mask of the prostate volume with 5 mm expansion. Residual registration errors were calculated after correcting for the initial introduced phantom set-up error. Registration performance with the OBI images was similar to that of XVI. There was a clear dependence on imaging dose for the XVI images with residual errors increasing below 4mGy. It was not possible to acquire images with doses lower than ~5mGy with the OBI system and no evidence of reduced performance was observed at this dose. Registration failures (maximum target registration error > 3.6 mm on the surface of a 30mm sphere) occurred in 5% to 9% of registrations except for the lowest dose XVI scan (31%). The uncertainty in automatic image registration with both OBI and XVI images was found to be adequate for clinical use within a normal range of acquisition settings.

  2. Imaging Characteristics of Children with Auditory Neuropathy Spectrum Disorder

    PubMed Central

    Roche, Joseph P.; Huang, Benjamin Y.; Castillo, Mauricio; Bassim, Marc K.; Adunka, Oliver F.; Buchman, Craig A.

    2013-01-01

    Objective To identify and define the imaging characteristics of children with auditory neuropathy spectrum disorder (ANSD). Design Retrospective medical records review and analysis of both temporal bone computed tomography (CT) and magnetic resonance images (MRI) in from children with the diagnosis of ANSD. Setting Tertiary referral center. Patients 118 children with the electrophysiological characteristics of ANSD with available imaging studies for review. Interventions Two neuroradiologists and a neurotologist reviewed each study and consensus descriptions were established. Main outcome measures The type and number of imaging findings were tabulated. Results Sixty-eight (64%) MRIs revealed at least one imaging abnormality while selective use of CT identified 23 (55%) with anomalies. The most prevalent MRI findings included cochlear nerve deficiency (n=51; 28% of 183 nerves), brain abnormalities (n=42; 40% of 106 brains) and prominent temporal horns (n=33, 16% of 212 temporal lobes). The most prevalent CT finding from selective use of CT was cochlear dysplasia (n=13; 31%). Conclusions MRI will identify many abnormalities in children with ANSD that are not readily discernable on CT. Specifically, both developmental and acquired abnormalities of the brain, posterior cranial fossa, and cochlear nerves are not uncommonly seen in this patient population. Inner ear anomalies are well delineated using either imaging modality. Since many of the central nervous system findings identified in this study using MRI can alter the treatment and prognosis for these children, we believe that MRI should be the initial imaging study of choice for children with ANSD. PMID:20593543

  3. Collaborative Initiative on Fetal Alcohol Spectrum Disorders: Methodology of Clinical Projects

    PubMed Central

    Mattson, Sarah N.; Foroud, Tatiana; Sowell, Elizabeth R.; Jones, Kenneth Lyons; Coles, Claire D.; Fagerlund, Åse; Autti-Rämö, Ilona; May, Philip A.; Adnams, Colleen M.; Konovalova, Valentina; Wetherill, Leah; Arenson, Andrew D.; Barnett, William K.; Riley, Edward P.

    2009-01-01

    The Collaborative Initiative on Fetal Alcohol Spectrum Disorders (CIFASD) was created in 2003 to further understanding of fetal alcohol spectrum disorders. Clinical and basic science projects collect data across multiple sites using standardized methodology. This paper describes the methodology being used by the clinical projects that pertain to assessment of children and adolescents. Domains being addressed are dysmorphology, neurobehavior, 3D facial imaging, and brain imaging. PMID:20036488

  4. Facebook use and negative body image among U.S. college women.

    PubMed

    Eckler, Petya; Kalyango, Yusuf; Paasch, Ellen

    2017-02-01

    Young women increasingly spend time on social media, but the relationship of this exposure to body image is still in the initial stages of exploration. In this study the authors used social comparison theory to examine the relationship between time spent on Facebook and body image. A survey of 881 U.S. college women was conducted in April-May 2013. Findings showed that 10.1% had posted about weight, body image, exercise, or dieting, and 27.4% had commented on friends' posts or photos. More time on Facebook related to more frequent body and weight comparisons, more attention to the physical appearance of others, and more negative feelings about their bodies for all women. For women who wanted to lose weight, more time on Facebook also related to more disordered eating symptoms.

  5. Knee osteoarthritis image registration: data from the Osteoarthritis Initiative

    NASA Astrophysics Data System (ADS)

    Galván-Tejada, Jorge I.; Celaya-Padilla, José M.; Treviño, Victor; Tamez-Peña, José G.

    2015-03-01

    Knee osteoarthritis is a very common disease, in early stages, changes in joint structures are shown, some of the most common symptoms are; formation of osteophytes, cartilage degradation and joint space reduction, among others. Based on a joint space reduction measurement, Kellgren-Lawrence grading scale, is a very extensive used tool to asses radiological OA knee x-ray images, based on information obtained from these assessments, the objective of this work is to correlate the Kellgren-Lawrence score to the bilateral asymmetry between knees. Using public data from the Osteoarthritis initiative (OAI), a set of images with different Kellgren-Lawrencescores were used to determine a relationship of Kellgren-Lawrence score and the bilateral asymmetry, in order to measure the asymmetry between the knees, the right knee was registered to match the left knee, then a series of similarity metrics, mutual information, correlation, and mean squared error where computed to correlate the deformation (mismatch) of the knees to the Kellgren-Lawrence score. Radiological information was evaluated and scored by OAI radiologist groups. The results of the study suggest an association between Radiological Kellgren-Lawrence score and image registration metrics, mutual information and correlation is higher in the early stages, and mean squared error is higher in advanced stages. This association can be helpful to develop a computer aided grading tool.

  6. Incidence of apical crack initiation and propagation during the removal of root canal filling material with ProTaper and Mtwo rotary nickel-titanium retreatment instruments and hand files.

    PubMed

    Topçuoğlu, Hüseyin Sinan; Düzgün, Salih; Kesim, Bertan; Tuncay, Oznur

    2014-07-01

    The aim of this study was to determine the incidence of crack initiation and propagation in apical root dentin after retreatment procedures performed by using 2 rotary retreatment systems and hand files with additional instrumentation. Eighty extracted mandibular premolars with single canals were selected. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the control group, and no preparation was performed. The remaining 60 teeth were prepared to size 35 with rotary files and filled with gutta-percha and AH Plus sealer. Specimens were then divided into 3 groups (n = 20), and retreatment procedures were performed with the following devices and techniques: ProTaper Universal retreatment files, Mtwo retreatment files, and hand files. After retreatment, the additional instrumentation was performed by using size 40 ProTaper, Mtwo, and hand files. Digital images of the apical root surface were recorded before preparation, after instrumentation, after filling, after retreatment, and after additional instrumentation. The images were then inspected for the presence of any new apical cracks and propagation. Data were analyzed with the logistic regression and Fisher exact tests. All experimental groups caused crack initiation and propagation after use of retreatment instruments. The ProTaper and Mtwo retreatment groups caused greater crack initiation and propagation than the hand instrument group (P < .05) after retreatment. Additional instrumentation with ProTaper and Mtwo instruments after the use of retreatment instruments caused crack initiation and propagation, whereas hand files caused neither crack initiation nor propagation (P < .05). This study showed that retreatment procedures and additional instrumentation after the use of retreatment files may cause crack initiation and propagation in apical dentin. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Avoiding misdiagnosing neuroblastoma as Wilms tumor.

    PubMed

    Dickson, Paxton V; Sims, Thomas L; Streck, Christian J; McCarville, M Beth; Santana, Victor M; McGregor, Lisa M; Furman, Wayne L; Davidoff, Andrew M

    2008-06-01

    Although occasionally difficult, distinguishing abdominal neuroblastoma (NBL) from Wilms tumor (WT) at presentation is important, as surgical management differs significantly. We reviewed our 20-year experience (1987-2006) treating patients with NBL, focusing on those with an initial diagnosis of WT, to determine presenting features that would have suggested the correct preoperative diagnosis. Retrospective case cohort study reviewing charts and imaging of patients with NBL initially diagnosed clinically with WT. Preoperative symptoms, laboratory studies, and imaging were evaluated. Similar variables were assessed in the 20 patients with WT most recently treated at our institution. Nine patients with NBL were identified as those who had an exploratory laparotomy with a preoperative diagnosis of WT; 8 underwent nephrectomy at exploration. Children with NBL had symptoms such as fever and weight loss at presentation (67%) more often than patients with WT (20%). Preoperative computed tomography demonstrated intratumoral calcifications, vascular encasement, or both in 78% of patients with NBL but were never seen in WT patients. Of interest, preoperative urinary catecholamines were elevated in 5 patients ultimately diagnosed with NBL. Although NBL can be mistaken for WT at presentation, the presence of constitutional symptoms, or intratumoral calcification or vascular encasement on preoperative imaging should heighten suspicion for NBL. In addition, laboratory evaluation, including urinary catecholamines, should be completed before surgery when the etiology of an abdominal tumor is uncertain.

  8. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): A Completed Reference Database of Lung Nodules on CT Scans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2011-02-15

    Purpose: The development of computer-aided diagnostic (CAD) methods for lung nodule detection, classification, and quantitative assessment can be facilitated through a well-characterized repository of computed tomography (CT) scans. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI) completed such a database, establishing a publicly available reference for the medical imaging research community. Initiated by the National Cancer Institute (NCI), further advanced by the Foundation for the National Institutes of Health (FNIH), and accompanied by the Food and Drug Administration (FDA) through active participation, this public-private partnership demonstrates the success of a consortium founded on a consensus-based process.more » Methods: Seven academic centers and eight medical imaging companies collaborated to identify, address, and resolve challenging organizational, technical, and clinical issues to provide a solid foundation for a robust database. The LIDC/IDRI Database contains 1018 cases, each of which includes images from a clinical thoracic CT scan and an associated XML file that records the results of a two-phase image annotation process performed by four experienced thoracic radiologists. In the initial blinded-read phase, each radiologist independently reviewed each CT scan and marked lesions belonging to one of three categories (''nodule{>=}3 mm,''''nodule<3 mm,'' and ''non-nodule{>=}3 mm''). In the subsequent unblinded-read phase, each radiologist independently reviewed their own marks along with the anonymized marks of the three other radiologists to render a final opinion. The goal of this process was to identify as completely as possible all lung nodules in each CT scan without requiring forced consensus. Results: The Database contains 7371 lesions marked ''nodule'' by at least one radiologist. 2669 of these lesions were marked ''nodule{>=}3 mm'' by at least one radiologist, of which 928 (34.7%) received such marks from all four radiologists. These 2669 lesions include nodule outlines and subjective nodule characteristic ratings. Conclusions: The LIDC/IDRI Database is expected to provide an essential medical imaging research resource to spur CAD development, validation, and dissemination in clinical practice.« less

  9. Development and Initial Evaluation of 7 Tesla Q-Ball Imaging of the Human Brain

    PubMed Central

    Mukherjee, Pratik; Hess, Christopher P.; Xu, Duan; Han, Eric T.; Kelley, Douglas A.; Vigneron, Daniel B.

    2010-01-01

    Diffusion tensor imaging (DTI) noninvasively depicts white matter connectivity in regions where the Gaussian model of diffusion is valid, but yields inaccurate results where diffusion has a more complex distribution, such as fiber crossings. Q-ball imaging (QBI) overcomes this limitation of DTI by more fully characterizing the angular dependence of intravoxel diffusion with larger numbers of diffusion-encoding directional measurements at higher diffusion-weighting factors (b values). However, the former results in longer acquisition times and the latter results in lower signal-to-noise ratio (SNR). In this project, we developed specialized 7 Tesla acquisition methods utilizing novel radiofrequency pulses, 8-channel parallel imaging EPI, and high-order shimming with a phase-sensitive multichannel B0 field map reconstruction. These methods were applied in initial healthy adult volunteer studies which demonstrated the feasibility of performing 7T QBI. Preliminary comparisons of 3T with 7T within supratentorial crossing white matter tracts document a 79.5% SNR increase for b=3000 s/mm2 (p=0.0001), and a 38.6% SNR increase for b=6000 s/mm2 (p=0.015). Using spherical harmonic reconstruction of the q-ball orientation distribution function at b=3000 s/mm2, 7T QBI allowed accurate visualization of crossing fiber tracts with fewer diffusion-encoding acquisitions than at 3T. The improvement of 7T QBI at b factors as high as 6000 s/mm2 resulted in better angular resolution than 3T for depicting fibers crossing at shallow angles. Although the increased susceptibility effects at 7T caused problematic distortions near brain-air interfaces at the skull base and posterior fossa, these initial 7T QBI studies demonstrated excellent quality in much of the supratentorial brain with significant improvements as compared to 3T acquisitions in the same individuals. PMID:17692489

  10. Accuracy of Computed Tomography for Predicting Pathologic Nodal Extracapsular Extension in Patients With Head-and-Neck Cancer Undergoing Initial Surgical Resection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prabhu, Roshan S., E-mail: roshansprabhu@gmail.com; Winship Cancer Institute, Emory University, Atlanta, Georgia; Magliocca, Kelly R.

    2014-01-01

    Purpose: Nodal extracapsular extension (ECE) in patients with head-and-neck cancer increases the loco-regional failure risk and is an indication for adjuvant chemoradiation therapy (CRT). To reduce the risk of requiring trimodality therapy, patients with head-and-neck cancer who are surgical candidates are often treated with definitive CRT when preoperative computed tomographic imaging suggests radiographic ECE. The purpose of this study was to assess the accuracy of preoperative CT imaging for predicting pathologic nodal ECE (pECE). Methods and Materials: The study population consisted of 432 consecutive patients with oral cavity or locally advanced/nonfunctional laryngeal cancer who underwent preoperative CT imaging before initialmore » surgical resection and neck dissection. Specimens with pECE had the extent of ECE graded on a scale from 1 to 4. Results: Radiographic ECE was documented in 46 patients (10.6%), and pECE was observed in 87 (20.1%). Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 43.7%, 97.7%, 82.6%, and 87.3%, respectively. The sensitivity of radiographic ECE increased from 18.8% for grade 1 to 2 ECE, to 52.9% for grade 3, and 72.2% for grade 4. Radiographic ECE criteria of adjacent structure invasion was a better predictor than irregular borders/fat stranding for pECE. Conclusions: Radiographic ECE has poor sensitivity, but excellent specificity for pECE in patients who undergo initial surgical resection. PPV and NPV are reasonable for clinical decision making. The performance of preoperative CT imaging increased as pECE grade increased. Patients with resectable head-and-neck cancer with radiographic ECE based on adjacent structure invasion are at high risk for high-grade pECE requiring adjuvant CRT when treated with initial surgery; definitive CRT as an alternative should be considered where appropriate.« less

  11. Microscope-Integrated OCT Feasibility and Utility With the EnFocus System in the DISCOVER Study.

    PubMed

    Runkle, Anne; Srivastava, Sunil K; Ehlers, Justis P

    2017-03-01

    To evaluate the feasibility and utility of a novel microscope-integrated intraoperative optical coherence tomography (OCT) system. The DISCOVER study is an investigational device study evaluating microscope-integrated intraoperative OCT systems for ophthalmic surgery. This report focuses on subjects imaged with the EnFocus prototype system (Leica Microsystems/Bioptigen, Morrisville, NC). OCT was performed at surgeon-directed milestones. Surgeons completed a questionnaire after each case to evaluate the impact of OCT on intraoperative management. Fifty eyes underwent imaging with the EnFocus system. Successful imaging was obtained in 46 of 50 eyes (92%). In eight cases (16%), surgical management was changed based on intraoperative OCT findings. In membrane peeling procedures, intraoperative OCT findings were discordant from the surgeon's initial impression in seven of 20 cases (35%). This study demonstrates the feasibility of microscope-integrated intraoperative OCT using the Bioptigen EnFocus system. Intraoperative OCT may provide surgeons with additional information that may influence surgical decision-making. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:216-222.]. Copyright 2017, SLACK Incorporated.

  12. Combining wet etching and real-time damage event imaging to reveal the most dangerous laser damage initiator in fused silica.

    PubMed

    Hu, Guohang; Zhao, Yuanan; Liu, Xiaofeng; Li, Dawei; Xiao, Qiling; Yi, Kui; Shao, Jianda

    2013-08-01

    A reliable method, combining a wet etch process and real-time damage event imaging during a raster scan laser damage test, has been developed to directly determine the most dangerous precursor inducing low-density laser damage at 355 nm in fused silica. It is revealed that ~16% of laser damage sites were initiated at the place of the scratches, ~49% initiated at the digs, and ~35% initiated at invisible defects. The morphologies of dangerous scratches and digs were compared with those of moderate ones. It is found that local sharp variation at the edge, twist, or inside of a subsurface defect is the most dangerous laser damage precursor.

  13. Coregistered photoacoustic and ultrasound imaging and classification of ovarian cancer: ex vivo and in vivo studies

    NASA Astrophysics Data System (ADS)

    Salehi, Hassan S.; Li, Hai; Merkulov, Alex; Kumavor, Patrick D.; Vavadi, Hamed; Sanders, Melinda; Kueck, Angela; Brewer, Molly A.; Zhu, Quing

    2016-04-01

    Most ovarian cancers are diagnosed at advanced stages due to the lack of efficacious screening techniques. Photoacoustic tomography (PAT) has a potential to image tumor angiogenesis and detect early neovascular changes of the ovary. We have developed a coregistered PAT and ultrasound (US) prototype system for real-time assessment of ovarian masses. Features extracted from PAT and US angular beams, envelopes, and images were input to a logistic classifier and a support vector machine (SVM) classifier to diagnose ovaries as benign or malignant. A total of 25 excised ovaries of 15 patients were studied and the logistic and SVM classifiers achieved sensitivities of 70.4 and 87.7%, and specificities of 95.6 and 97.9%, respectively. Furthermore, the ovaries of two patients were noninvasively imaged using the PAT/US system before surgical excision. By using five significant features and the logistic classifier, 12 out of 14 images (86% sensitivity) from a malignant ovarian mass and all 17 images (100% specificity) from a benign mass were accurately classified; the SVM correctly classified 10 out of 14 malignant images (71% sensitivity) and all 17 benign images (100% specificity). These initial results demonstrate the clinical potential of the PAT/US technique for ovarian cancer diagnosis.

  14. Hyperspectral imaging fluorescence excitation scanning for colon cancer detection

    NASA Astrophysics Data System (ADS)

    Leavesley, Silas J.; Walters, Mikayla; Lopez, Carmen; Baker, Thomas; Favreau, Peter F.; Rich, Thomas C.; Rider, Paul F.; Boudreaux, Carole W.

    2016-10-01

    Optical spectroscopy and hyperspectral imaging have shown the potential to discriminate between cancerous and noncancerous tissue with high sensitivity and specificity. However, to date, these techniques have not been effectively translated to real-time endoscope platforms. Hyperspectral imaging of the fluorescence excitation spectrum represents new technology that may be well suited for endoscopic implementation. However, the feasibility of detecting differences between normal and cancerous mucosa using fluorescence excitation-scanning hyperspectral imaging has not been evaluated. The goal of this study was to evaluate the initial feasibility of using fluorescence excitation-scanning hyperspectral imaging for measuring changes in fluorescence excitation spectrum concurrent with colonic adenocarcinoma using a small pre-pilot-scale sample size. Ex vivo analysis was performed using resected pairs of colorectal adenocarcinoma and normal mucosa. Adenocarcinoma was confirmed by histologic evaluation of hematoxylin and eosin (H&E) permanent sections. Specimens were imaged using a custom hyperspectral imaging fluorescence excitation-scanning microscope system. Results demonstrated consistent spectral differences between normal and cancerous tissues over the fluorescence excitation range of 390 to 450 nm that could be the basis for wavelength-dependent detection of colorectal cancers. Hence, excitation-scanning hyperspectral imaging may offer an alternative approach for discriminating adenocarcinoma from surrounding normal colonic mucosa, but further studies will be required to evaluate the accuracy of this approach using a larger patient cohort.

  15. Noninvasive cardiac activation imaging of ventricular arrhythmias during drug-induced QT prolongation in the rabbit heart.

    PubMed

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; Zhou, Zhaoye; He, Bin

    2013-10-01

    Imaging myocardial activation from noninvasive body surface potentials promises to aid in both cardiovascular research and clinical medicine. To investigate the ability of a noninvasive 3-dimensional cardiac electrical imaging technique for characterizing the activation patterns of dynamically changing ventricular arrhythmias during drug-induced QT prolongation in rabbits. Simultaneous body surface potential mapping and 3-dimensional intracardiac mapping were performed in a closed-chest condition in 8 rabbits. Data analysis was performed on premature ventricular complexes, couplets, and torsades de pointes (TdP) induced during intravenous administration of clofilium and phenylephrine with combinations of various infusion rates. The drug infusion led to a significant increase in the QT interval (from 175 ± 7 to 274 ± 31 ms) and rate-corrected QT interval (from 183 ± 5 to 262 ± 21 ms) during the first dose cycle. All the ectopic beats initiated by a focal activation pattern. The initial beat of TdPs arose at the focal site, whereas the subsequent beats were due to focal activity from different sites or 2 competing focal sites. The imaged results captured the dynamic shift of activation patterns and were in good correlation with the simultaneous measurements, with a correlation coefficient of 0.65 ± 0.02 averaged over 111 ectopic beats. Sites of initial activation were localized to be ~5 mm from the directly measured initiation sites. The 3-dimensional cardiac electrical imaging technique could localize the origin of activation and image activation sequence of TdP during QT prolongation induced by clofilium and phenylephrine in rabbits. It offers the potential to noninvasively investigate the proarrhythmic effects of drug infusion and assess the mechanisms of arrhythmias on a beat-to-beat basis. © 2013 Heart Rhythm Society. All rights reserved.

  16. Imaging of post-traumatic hearing loss.

    PubMed

    Mazón, M; Pont, E; Albertz, N; Carreres-Polo, J; Más-Estellés, F

    Hearing loss is the most frequent complication of temporal bone trauma. The role of the radiologist is of great importance; the adequacy and selection of the imaging technique, as well as its correct interpretation, are crucial to establish the diagnosis, prognosis and enable the selection of appropriate treatment. With the aim of systematizing the most relevant concepts in the evaluation of image studies in this scenario, this review will be outlined according to the hearing loss type. The potential lesions of its components will be assessed; In each case the most appropriate imaging technique will be suggested and the findings will be described and depicted. In postraumatic hearing loss, computed tomography is the initial technique of choice and will allow the detection of alterations that cause conductive hearing loss; magnetic resonance imaging will be useful in the evaluation of sensorineural hearing loss. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Cellular resolution functional imaging in behaving rats using voluntary head restraint

    PubMed Central

    Scott, Benjamin B.; Brody, Carlos D.; Tank, David W.

    2013-01-01

    SUMMARY High-throughput operant conditioning systems for rodents provide efficient training on sophisticated behavioral tasks. Combining these systems with technologies for cellular resolution functional imaging would provide a powerful approach to study neural dynamics during behavior. Here we describe an integrated two-photon microscope and behavioral apparatus that allows cellular resolution functional imaging of cortical regions during epochs of voluntary head restraint. Rats were trained to initiate periods of restraint up to 8 seconds in duration, which provided the mechanical stability necessary for in vivo imaging while allowing free movement between behavioral trials. A mechanical registration system repositioned the head to within a few microns, allowing the same neuronal populations to be imaged on each trial. In proof-of-principle experiments, calcium dependent fluorescence transients were recorded from GCaMP-labeled cortical neurons. In contrast to previous methods for head restraint, this system can also be incorporated into high-throughput operant conditioning systems. PMID:24055015

  18. Initial Investigation of preclinical integrated SPECT and MR imaging.

    PubMed

    Hamamura, Mark J; Ha, Seunghoon; Roeck, Werner W; Wagenaar, Douglas J; Meier, Dirk; Patt, Bradley E; Nalcioglu, Orhan

    2010-02-01

    Single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high-spatial resolution anatomical information as well as complementary functional information. In this study, we utilized a dual modality SPECT/MRI (MRSPECT) system to investigate the integration of SPECT and MRI for improved image accuracy. The MRSPECT system consisted of a cadmium-zinc-telluride (CZT) nuclear radiation detector interfaced with a specialized radiofrequency (RF) coil that was placed within a whole-body 4 T MRI system. The importance of proper corrections for non-uniform detector sensitivity and Lorentz force effects was demonstrated. MRI data were utilized for attenuation correction (AC) of the nuclear projection data and optimized Wiener filtering of the SPECT reconstruction for improved image accuracy. Finally, simultaneous dual-imaging of a nude mouse was performed to demonstrated the utility of co-registration for accurate localization of a radioactive source.

  19. Initial Investigation of Preclinical Integrated SPECT and MR Imaging

    PubMed Central

    Hamamura, Mark J.; Ha, Seunghoon; Roeck, Werner W.; Wagenaar, Douglas J.; Meier, Dirk; Patt, Bradley E.; Nalcioglu, Orhan

    2014-01-01

    Single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high-spatial resolution anatomical information as well as complementary functional information. In this study, we utilized a dual modality SPECT/MRI (MRSPECT) system to investigate the integration of SPECT and MRI for improved image accuracy. The MRSPECT system consisted of a cadmium-zinc-telluride (CZT) nuclear radiation detector interfaced with a specialized radiofrequency (RF) coil that was placed within a whole-body 4 T MRI system. The importance of proper corrections for non-uniform detector sensitivity and Lorentz force effects was demonstrated. MRI data were utilized for attenuation correction (AC) of the nuclear projection data and optimized Wiener filtering of the SPECT reconstruction for improved image accuracy. Finally, simultaneous dual-imaging of a nude mouse was performed to demonstrated the utility of co-registration for accurate localization of a radioactive source. PMID:20082527

  20. First Point-Spread Function and X-Ray Phase Contrast Imaging Results with an 88-mm Diameter Single Crystal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lumpkin, A. H.; Garson, A. B.; Anastasio, M. A.

    In this study, we report initial demonstrations of the use of single crystals in indirect x-ray imaging with a benchtop implementation of propagation-based (PB) x-ray phase contrast imaging. Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point-spread function (PSF) with the 50-μm thick single crystal scintillators than with the reference polycrystalline phosphor/scintillator. Fiber-optic plate depth-of-focus and Al reflective-coating aspects are also elucidated. Guided by the results from the 25-mm diameter crystal samples, we report additionally the first results with a unique 88-mm diameter single crystal bonded to a fiber optic platemore » and coupled to the large format CCD. Both PSF and x-ray phase contrast imaging data are quantified and presented.« less

  1. Rendering-based video-CT registration with physical constraints for image-guided endoscopic sinus surgery

    NASA Astrophysics Data System (ADS)

    Otake, Y.; Leonard, S.; Reiter, A.; Rajan, P.; Siewerdsen, J. H.; Ishii, M.; Taylor, R. H.; Hager, G. D.

    2015-03-01

    We present a system for registering the coordinate frame of an endoscope to pre- or intra- operatively acquired CT data based on optimizing the similarity metric between an endoscopic image and an image predicted via rendering of CT. Our method is robust and semi-automatic because it takes account of physical constraints, specifically, collisions between the endoscope and the anatomy, to initialize and constrain the search. The proposed optimization method is based on a stochastic optimization algorithm that evaluates a large number of similarity metric functions in parallel on a graphics processing unit. Images from a cadaver and a patient were used for evaluation. The registration error was 0.83 mm and 1.97 mm for cadaver and patient images respectively. The average registration time for 60 trials was 4.4 seconds. The patient study demonstrated robustness of the proposed algorithm against a moderate anatomical deformation.

  2. Multi-focus image fusion using a guided-filter-based difference image.

    PubMed

    Yan, Xiang; Qin, Hanlin; Li, Jia; Zhou, Huixin; Yang, Tingwu

    2016-03-20

    The aim of multi-focus image fusion technology is to integrate different partially focused images into one all-focused image. To realize this goal, a new multi-focus image fusion method based on a guided filter is proposed and an efficient salient feature extraction method is presented in this paper. Furthermore, feature extraction is primarily the main objective of the present work. Based on salient feature extraction, the guided filter is first used to acquire the smoothing image containing the most sharpness regions. To obtain the initial fusion map, we compose a mixed focus measure by combining the variance of image intensities and the energy of the image gradient together. Then, the initial fusion map is further processed by a morphological filter to obtain a good reprocessed fusion map. Lastly, the final fusion map is determined via the reprocessed fusion map and is optimized by a guided filter. Experimental results demonstrate that the proposed method does markedly improve the fusion performance compared to previous fusion methods and can be competitive with or even outperform state-of-the-art fusion methods in terms of both subjective visual effects and objective quality metrics.

  3. A novel chaos-based image encryption algorithm using DNA sequence operations

    NASA Astrophysics Data System (ADS)

    Chai, Xiuli; Chen, Yiran; Broyde, Lucie

    2017-01-01

    An image encryption algorithm based on chaotic system and deoxyribonucleic acid (DNA) sequence operations is proposed in this paper. First, the plain image is encoded into a DNA matrix, and then a new wave-based permutation scheme is performed on it. The chaotic sequences produced by 2D Logistic chaotic map are employed for row circular permutation (RCP) and column circular permutation (CCP). Initial values and parameters of the chaotic system are calculated by the SHA 256 hash of the plain image and the given values. Then, a row-by-row image diffusion method at DNA level is applied. A key matrix generated from the chaotic map is used to fuse the confused DNA matrix; also the initial values and system parameters of the chaotic system are renewed by the hamming distance of the plain image. Finally, after decoding the diffused DNA matrix, we obtain the cipher image. The DNA encoding/decoding rules of the plain image and the key matrix are determined by the plain image. Experimental results and security analyses both confirm that the proposed algorithm has not only an excellent encryption result but also resists various typical attacks.

  4. Neurobiological Risk Factors for Suicide Insights from Brain Imaging

    PubMed Central

    Cox Lippard, Elizabeth T.; Johnston, Jennifer A.Y.; Blumberg, Hilary P.

    2014-01-01

    Context This article reviews neuroimaging studies on neural circuitry associated with suicide-related thoughts and behaviors to identify areas of convergence in findings. Gaps in the literature for which additional research is needed are identified. Evidence acquisition A PubMed search was conducted and articles published prior to March 2014 were reviewed that compared individuals who made suicide attempts to those with similar diagnoses who had not made attempts or to healthy comparison subjects. Articles on adults with suicidal ideation and adolescents who had made attempts, or with suicidal ideation, were also included. Reviewed imaging modalities included structural magnetic resonance imaging, diffusion tensor imaging, single photon emission computerized tomography, positron emission tomography, and functional magnetic resonance imaging. Evidence synthesis Although many studies include small samples, and subject characteristics and imaging methods vary across studies, there were convergent findings involving the structure and function of frontal neural systems and the serotonergic system. Conclusions These initial neuroimaging studies of suicide behavior have provided promising results. Future neuroimaging efforts could be strengthened by more strategic use of common data elements, and a focus on suicide risk trajectories. At-risk subgroups defined by biopsychosocial risk factors and multidimensional assessment of suicidal thoughts and behaviors may provide a clearer picture of the neural circuitry associated with risk status—both current and lifetime. Also needed are studies investigating neural changes associated with interventions that are effective in risk reduction. PMID:25145733

  5. Topological charge number multiplexing for JTC multiple-image encryption

    NASA Astrophysics Data System (ADS)

    Chen, Qi; Shen, Xueju; Dou, Shuaifeng; Lin, Chao; Wang, Long

    2018-04-01

    We propose a method of topological charge number multiplexing based on the JTC encryption system to achieve multiple-image encryption. Using this method, multi-image can be encrypted into single ciphertext, and the original images can be recovered according to the authority level. The number of encrypted images is increased, moreover, the quality of decrypted images is improved. Results of computer simulation and initial experiment identify the validity of our proposed method.

  6. Blind CT image quality assessment via deep learning strategy: initial study

    NASA Astrophysics Data System (ADS)

    Li, Sui; He, Ji; Wang, Yongbo; Liao, Yuting; Zeng, Dong; Bian, Zhaoying; Ma, Jianhua

    2018-03-01

    Computed Tomography (CT) is one of the most important medical imaging modality. CT images can be used to assist in the detection and diagnosis of lesions and to facilitate follow-up treatment. However, CT images are vulnerable to noise. Actually, there are two major source intrinsically causing the CT data noise, i.e., the X-ray photo statistics and the electronic noise background. Therefore, it is necessary to doing image quality assessment (IQA) in CT imaging before diagnosis and treatment. Most of existing CT images IQA methods are based on human observer study. However, these methods are impractical in clinical for their complex and time-consuming. In this paper, we presented a blind CT image quality assessment via deep learning strategy. A database of 1500 CT images is constructed, containing 300 high-quality images and 1200 corresponding noisy images. Specifically, the high-quality images were used to simulate the corresponding noisy images at four different doses. Then, the images are scored by the experienced radiologists by the following attributes: image noise, artifacts, edge and structure, overall image quality, and tumor size and boundary estimation with five-point scale. We trained a network for learning the non-liner map from CT images to subjective evaluation scores. Then, we load the pre-trained model to yield predicted score from the test image. To demonstrate the performance of the deep learning network in IQA, correlation coefficients: Pearson Linear Correlation Coefficient (PLCC) and Spearman Rank Order Correlation Coefficient (SROCC) are utilized. And the experimental result demonstrate that the presented deep learning based IQA strategy can be used in the CT image quality assessment.

  7. The Nature and Extent of Body Image Concerns Among Surgically Treated Patients with Head and Neck Cancer

    PubMed Central

    Fingeret, Michelle Cororve; Yuan, Ying; Urbauer, Diana; Weston, June; Nipomnick, Summer; Weber, Randal

    2016-01-01

    Objective The purpose of this study was to describe body image concerns for surgically treated patients with head and neck cancer and evaluate the relationship between body image concerns and quality of life outcomes. Methods Data were obtained from 280 patients undergoing surgical treatment for head and neck cancer. We used a cross-sectional design and obtained data from individuals at different time points relative to initiation of surgical treatment. Participants completed the Body Image Scale, the Functional Assessment of Cancer Therapy scale – Head and Neck version, and a survey designed for this study to evaluate disease-specific body image issues, satisfaction with care regarding body image issues, and interest in psychosocial intervention. Results Body image concerns were prevalent in the majority of participants with 75% acknowledging concerns or embarrassment about one or more types of bodily changes at some point during treatment. Significant associations were found between body image concerns and all major domains of quality of life. Age, gender, cancer type, time since surgery, and body image variables were significantly associated with psychosocial outcomes. A clear subset of participants expressed dissatisfaction with care received about body image issues and/or indicated they would have liked additional resources to help them cope with body image changes. Conclusions These data provide useful information to document wide-ranging body image difficulties for this population and provide important targets for the development of relevant psychosocial interventions. PMID:21706673

  8. Modification of a medical PET scanner for PEPT studies

    NASA Astrophysics Data System (ADS)

    Sadrmomtaz, Alireza; Parker, D. J.; Byars, L. G.

    2007-04-01

    Over the last 20 years, positron emission tomography (PET) has developed as the most powerful functional imaging modality in medicine. Over the same period the University of Birmingham Positron Imaging Centre has applied PET to study engineering processes and developed the alternative technique of positron emission particle tracking (PEPT) in which a single radioactively labelled tracer particle is tracked by detecting simultaneously the pairs of back-to-back photons arising from positron/electron annihilation. Originally PEPT was performed using a pair of multiwire detectors, and more recently using a pair of digital gamma camera heads. In 2002 the Positron Imaging Centre acquired a medical PET scanner, an ECAT 931/08, previously used at Hammersmith Hospital. This scanner has been rebuilt in a flexible geometry for use in PEPT studies. This paper presents initial results from this system. Fast moving tracer particles can be rapidly and accurately located.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carranza, Arturo; Gewin, Mariah; Pojman, John A., E-mail: japojman@lsu.edu

    In this study, we present an inexpensive and practical method that allows the monitoring and visualization of front polymerization, propagation, and dynamics. Commercially available europium-doped aluminum oxide powders were combined with video imaging to visualize free-radical propagating polymer fronts. In order to demonstrate the applicability of this method, frontal copolymerization reactions of propoxylated glycerin triacrylate (EB53), pentaerythritol triacrylate (PETA), and pentaerythritol tetra-acrylate (PETEA) with 1,1-Bis(tert-butylperoxy)-3,3,5-trimethylcyclohexane (Luperox 231®) as an initiator were studied and compared to the results obtained by IR imaging. Systems exhibiting higher filler loading, higher EB53 content, and less acrylated monomers showed a marked decrease in front velocity,more » while those with more acrylated monomers and higher crosslinking density showed a marked increase in front velocity. Finally, in order to show the potential of the imaging technique, we studied fronts propagating in planar and spherical geometries.« less

  10. Image correlation method for DNA sequence alignment.

    PubMed

    Curilem Saldías, Millaray; Villarroel Sassarini, Felipe; Muñoz Poblete, Carlos; Vargas Vásquez, Asticio; Maureira Butler, Iván

    2012-01-01

    The complexity of searches and the volume of genomic data make sequence alignment one of bioinformatics most active research areas. New alignment approaches have incorporated digital signal processing techniques. Among these, correlation methods are highly sensitive. This paper proposes a novel sequence alignment method based on 2-dimensional images, where each nucleic acid base is represented as a fixed gray intensity pixel. Query and known database sequences are coded to their pixel representation and sequence alignment is handled as object recognition in a scene problem. Query and database become object and scene, respectively. An image correlation process is carried out in order to search for the best match between them. Given that this procedure can be implemented in an optical correlator, the correlation could eventually be accomplished at light speed. This paper shows an initial research stage where results were "digitally" obtained by simulating an optical correlation of DNA sequences represented as images. A total of 303 queries (variable lengths from 50 to 4500 base pairs) and 100 scenes represented by 100 x 100 images each (in total, one million base pair database) were considered for the image correlation analysis. The results showed that correlations reached very high sensitivity (99.01%), specificity (98.99%) and outperformed BLAST when mutation numbers increased. However, digital correlation processes were hundred times slower than BLAST. We are currently starting an initiative to evaluate the correlation speed process of a real experimental optical correlator. By doing this, we expect to fully exploit optical correlation light properties. As the optical correlator works jointly with the computer, digital algorithms should also be optimized. The results presented in this paper are encouraging and support the study of image correlation methods on sequence alignment.

  11. Optimizing the Protocol for Pulmonary Cryoablation: A Comparison of a Dual- and Triple-Freeze Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hinshaw, J. Louis, E-mail: jhinshaw@uwhealth.or; Littrup, Peter J.; Durick, Nathan

    2010-12-15

    The purpose of this study was to compare a double freeze-thaw protocol to a triple freeze-thaw protocol for pulmonary cryoablation utilizing an in vivo porcine lung model. A total of 18 cryoablations were performed in normal porcine lung utilizing percutaneous technique with 9 each in a double- (10-5-10) and triple-freeze (3-3-7-7-5) protocol. Serial noncontrast CT images were obtained during the ablation. CT imaging findings and pathology were reviewed. No imaging changes were identified during the initial freeze cycle with either protocol. However, during the first thaw cycle, a region of ground glass opacity developed around the probe with both protocols.more » Because the initial freeze was shorter with the triple freeze-thaw protocol, the imaging findings were apparent sooner with this protocol (6 vs. 13 min). Also, despite a shorter total freeze time (15 vs. 20 min), the ablation zone identified with the triple freeze-thaw protocol was not significantly different from the double freeze-thaw protocol (mean diameter: 1.67 {+-} 0.41 cm vs. 1.66 {+-} 0.21 cm, P = 0.77; area: 2.1 {+-} 0.48 cm{sup 2} vs. 1.99 {+-} 0.62 cm{sup 2}, P = 0.7; and circularity: 0.95 {+-} 0.04 vs. 0.96 {+-} 0.03, P = 0.62, respectively). This study suggests that there may be several advantages of a triple freeze-thaw protocol for pulmonary cryoablation, including earlier identification of the imaging findings associated with the ablation, the promise of a shorter procedure time or larger zones of ablation, and theoretically, more effective cytotoxicity related to the additional freeze-thaw cycle.« less

  12. Foraminiferal Metabolism Under Hypoxia: Sub-Cellular NanoSIMS Imaging of Intertidal Ammonia tepida Feeding Behavior

    NASA Astrophysics Data System (ADS)

    LeKieffre, C.; Spangenberg, J.; Geslin, E.; Meibom, A.

    2016-02-01

    Hypoxic events particularly affect benthic ecosystems on continental shelves and in coastal areas where renewal of bottom waters slow. Foraminifera living in such environments are among the most tolerant to hypoxia in the meiofauna. Some foraminifera species are able to survive hypoxia, and even anoxia, for weeks to months. Different species must have developed different mechanisms for survival - hypotheses include reduction of the metabolism, symbiosis with bacteria, or denitrification. NanoSIMS (Secondary Ion Mass Spectrometry) imaging is a powerful analytical technique to visualize and quantify the incorporation and transfer of isotopically labeled compounds in organisms with subcellular resolution. We used NanoSIMS imaging, correlated with TEM ultrastructural observations of individual foraminifera, to study the metabolism of intertidal Ammonia tepida, which has shown strongly reduced metabolism under anoxia. Individuals were fed with a 13C-labeled microalgal biofilm and incubated for 4 weeks in oxic and anoxic conditions, respectively. NanoSIMS imaging reveal strongly contrasting cellular-level dynamics of integration and transfer of the ingested biofilm components under the two conditions. In oxic conditions, ingested biofilm components are internalized, metabolized, and used for biosynthesis of different cellular components on a time scale of 24 hours: Lipid droplets are formed, then consumed through respiration. In contrast, upon the onset of anoxia, individual internalized biofilm components remain visible within the cytoplasm after 4 weeks. Lipids of different compositions are initially formed but then not respired. These observations indicate that foraminifera do initially have an active heterotrophic metabolism in the absence of oxygen, but this it is strongly reduced when oxygen is no longer available. Isotopic labeling experiments, NanoSIMS and TEM imaging, and GC-MS will be key to study metabolic mechanisms under anoxic conditions in marine environments.

  13. A comparative analysis of noncontrast flow-spoiled versus contrast-enhanced magnetic resonance angiography for evaluation of peripheral arterial disease.

    PubMed

    Kassamali, Rahil Hussein; Hoey, Edward T D; Ganeshan, Arul; Littlehales, Tracey

    2013-01-01

    This feasibility study aimed to obtain initial data to assess the performance of a novel noncontrast spoiled magnetic resonance (MR) angiography technique (fresh-blood imaging [FBI]) compared to gadolinium-enhanced MR (Gd-MR) angiography for evaluation of the aorto-iliac and lower extremity arteries. Thirteen patients with suspected lower extremity arterial disease that had undergone Gd-MR angiography and FBI at the same session were randomly included in the study. FBI was performed using an ECG-gated ow-spoiled T2-weighted half-Fourier fast spin-echo sequence. For analysis, the aortoiliac and lower limb arteries were divided into 18 anatomical segments. Two blinded readers individually graded image quality of FBI and also assessed the presence and severity of any stenotic lesions. A similar analysis was performed for the Gd-MR angiography images. A total of 385 arterial segments were analyzed; 34 segments were excluded due to degraded image quality (1.3% of Gd- MR vs. 8% of FBI-MR angiography images). FBI-MR angiography had comparable accuracy to Gd-MR angiography for assessment of the above knee vessels with high kappa statistics (large arteries, 0.91; small arteries, 0.86) and high sensitivity (large arteries, 98.1%; small arteries, 88.6%) and specificity (large arteries, 97.2%; small arteries, 97.6%) using Gd-MR angiography as the gold standard. Initial results show good agreement between FBI-MR angiography and Gd-MR angiography in the diagnosis of peripheral arterial disease, making FBI a potential alternative in patients with renal impairment. FBI showed highest accuracy in the above knee vessels. Technological refinements are required to improve accuracy for assessing the calf and pedal vessels.

  14. Update on the magnetic resonance imaging core of the Alzheimer's disease neuroimaging initiative.

    PubMed

    Jack, Clifford R; Bernstein, Matt A; Borowski, Bret J; Gunter, Jeffrey L; Fox, Nick C; Thompson, Paul M; Schuff, Norbert; Krueger, Gunnar; Killiany, Ronald J; Decarli, Charles S; Dale, Anders M; Carmichael, Owen W; Tosun, Duygu; Weiner, Michael W

    2010-05-01

    Functions of the Alzheimer's Disease Neuroimaging Initiative (ADNI) magnetic resonance imaging (MRI) core fall into three categories: (1) those of the central MRI core laboratory at Mayo Clinic, Rochester, Minnesota, needed to generate high quality MRI data in all subjects at each time point; (2) those of the funded ADNI MRI core imaging analysis groups responsible for analyzing the MRI data; and (3) the joint function of the entire MRI core in designing and problem solving MR image acquisition, pre-processing, and analyses methods. The primary objective of ADNI was and continues to be improving methods for clinical trials in Alzheimer's disease. Our approach to the present ("ADNI-GO") and future ("ADNI-2," if funded) MRI protocol will be to maintain MRI methodological consistency in the previously enrolled "ADNI-1" subjects who are followed up longitudinally in ADNI-GO and ADNI-2. We will modernize and expand the MRI protocol for all newly enrolled ADNI-GO and ADNI-2 subjects. All newly enrolled subjects will be scanned at 3T with a core set of three sequence types: 3D T1-weighted volume, FLAIR, and a long TE gradient echo volumetric acquisition for micro hemorrhage detection. In addition to this core ADNI-GO and ADNI-2 protocol, we will perform vendor-specific pilot sub-studies of arterial spin-labeling perfusion, resting state functional connectivity, and diffusion tensor imaging. One of these sequences will be added to the core protocol on systems from each MRI vendor. These experimental sub-studies are designed to demonstrate the feasibility of acquiring useful data in a multicenter (but single vendor) setting for these three emerging MRI applications. Copyright 2010 The Alzheimer

  15. Optics for Advanced Neutron Imaging and Scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moncton, David E.; Khaykovich, Boris

    2016-03-30

    During the report period, we continued the work as outlined in the original proposal. We have analyzed potential optical designs of Wolter mirrors for the neutron-imaging instrument VENUS, which is under construction at SNS. In parallel, we have conducted the initial polarized imaging experiment at Helmholtz Zentrum, Berlin, one of very few of currently available polarized-imaging facilities worldwide.

  16. Hard X-ray imaging from Explorer

    NASA Technical Reports Server (NTRS)

    Grindlay, J. E.; Murray, S. S.

    1981-01-01

    Coded aperture X-ray detectors were applied to obtain large increases in sensitivity as well as angular resolution. A hard X-ray coded aperture detector concept is described which enables very high sensitivity studies persistent hard X-ray sources and gamma ray bursts. Coded aperture imaging is employed so that approx. 2 min source locations can be derived within a 3 deg field of view. Gamma bursts were located initially to within approx. 2 deg and X-ray/hard X-ray spectra and timing, as well as precise locations, derived for possible burst afterglow emission. It is suggested that hard X-ray imaging should be conducted from an Explorer mission where long exposure times are possible.

  17. BgCut: automatic ship detection from UAV images.

    PubMed

    Xu, Chao; Zhang, Dongping; Zhang, Zhengning; Feng, Zhiyong

    2014-01-01

    Ship detection in static UAV aerial images is a fundamental challenge in sea target detection and precise positioning. In this paper, an improved universal background model based on Grabcut algorithm is proposed to segment foreground objects from sea automatically. First, a sea template library including images in different natural conditions is built to provide an initial template to the model. Then the background trimap is obtained by combing some templates matching with region growing algorithm. The output trimap initializes Grabcut background instead of manual intervention and the process of segmentation without iteration. The effectiveness of our proposed model is demonstrated by extensive experiments on a certain area of real UAV aerial images by an airborne Canon 5D Mark. The proposed algorithm is not only adaptive but also with good segmentation. Furthermore, the model in this paper can be well applied in the automated processing of industrial images for related researches.

  18. BgCut: Automatic Ship Detection from UAV Images

    PubMed Central

    Zhang, Zhengning; Feng, Zhiyong

    2014-01-01

    Ship detection in static UAV aerial images is a fundamental challenge in sea target detection and precise positioning. In this paper, an improved universal background model based on Grabcut algorithm is proposed to segment foreground objects from sea automatically. First, a sea template library including images in different natural conditions is built to provide an initial template to the model. Then the background trimap is obtained by combing some templates matching with region growing algorithm. The output trimap initializes Grabcut background instead of manual intervention and the process of segmentation without iteration. The effectiveness of our proposed model is demonstrated by extensive experiments on a certain area of real UAV aerial images by an airborne Canon 5D Mark. The proposed algorithm is not only adaptive but also with good segmentation. Furthermore, the model in this paper can be well applied in the automated processing of industrial images for related researches. PMID:24977182

  19. Automatic Image Registration of Multimodal Remotely Sensed Data with Global Shearlet Features

    NASA Technical Reports Server (NTRS)

    Murphy, James M.; Le Moigne, Jacqueline; Harding, David J.

    2015-01-01

    Automatic image registration is the process of aligning two or more images of approximately the same scene with minimal human assistance. Wavelet-based automatic registration methods are standard, but sometimes are not robust to the choice of initial conditions. That is, if the images to be registered are too far apart relative to the initial guess of the algorithm, the registration algorithm does not converge or has poor accuracy, and is thus not robust. These problems occur because wavelet techniques primarily identify isotropic textural features and are less effective at identifying linear and curvilinear edge features. We integrate the recently developed mathematical construction of shearlets, which is more effective at identifying sparse anisotropic edges, with an existing automatic wavelet-based registration algorithm. Our shearlet features algorithm produces more distinct features than wavelet features algorithms; the separation of edges from textures is even stronger than with wavelets. Our algorithm computes shearlet and wavelet features for the images to be registered, then performs least squares minimization on these features to compute a registration transformation. Our algorithm is two-staged and multiresolution in nature. First, a cascade of shearlet features is used to provide a robust, though approximate, registration. This is then refined by registering with a cascade of wavelet features. Experiments across a variety of image classes show an improved robustness to initial conditions, when compared to wavelet features alone.

  20. Automatic Image Registration of Multi-Modal Remotely Sensed Data with Global Shearlet Features

    PubMed Central

    Murphy, James M.; Le Moigne, Jacqueline; Harding, David J.

    2017-01-01

    Automatic image registration is the process of aligning two or more images of approximately the same scene with minimal human assistance. Wavelet-based automatic registration methods are standard, but sometimes are not robust to the choice of initial conditions. That is, if the images to be registered are too far apart relative to the initial guess of the algorithm, the registration algorithm does not converge or has poor accuracy, and is thus not robust. These problems occur because wavelet techniques primarily identify isotropic textural features and are less effective at identifying linear and curvilinear edge features. We integrate the recently developed mathematical construction of shearlets, which is more effective at identifying sparse anisotropic edges, with an existing automatic wavelet-based registration algorithm. Our shearlet features algorithm produces more distinct features than wavelet features algorithms; the separation of edges from textures is even stronger than with wavelets. Our algorithm computes shearlet and wavelet features for the images to be registered, then performs least squares minimization on these features to compute a registration transformation. Our algorithm is two-staged and multiresolution in nature. First, a cascade of shearlet features is used to provide a robust, though approximate, registration. This is then refined by registering with a cascade of wavelet features. Experiments across a variety of image classes show an improved robustness to initial conditions, when compared to wavelet features alone. PMID:29123329

  1. 78 FR 16531 - Certain Electronic Devices for Capturing and Transmitting Images, and Components Thereof...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-15

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-831] Certain Electronic Devices for Capturing and Transmitting Images, and Components Thereof; Commission Determination Not To Review an Initial... certain electronic devices for capturing and transmitting images, and components thereof. The complaint...

  2. A Novel Reporting System to Improve Accuracy in Appendicitis Imaging

    PubMed Central

    Godwin, Benjamin D.; Drake, Frederick T.; Simianu, Vlad V.; Shriki, Jabi E.; Hippe, Daniel S.; Dighe, Manjiri; Bastawrous, Sarah; Cuevas, Carlos; Flum, David; Bhargava, Puneet

    2015-01-01

    OBJECTIVE The purpose of this study was to ascertain if standardized radiologic reporting for appendicitis imaging increases diagnostic accuracy. MATERIALS AND METHODS We developed a standardized appendicitis reporting system that includes objective imaging findings common in appendicitis and a certainty score ranging from 1 (definitely not appendicitis) through 5 (definitely appendicitis). Four radiologists retrospectively reviewed the preoperative CT scans of 96 appendectomy patients using our reporting system. The presence of appendicitis-specific imaging findings and certainty scores were compared with final pathology. These comparisons were summarized using odds ratios (ORs) and the AUC. RESULTS The appendix was visualized on CT in 89 patients, of whom 71 (80%) had pathologically proven appendicitis. Imaging findings associated with appendicitis included appendiceal diameter (odds ratio [OR] = 14 [> 10 vs < 6 mm]; p = 0.002), periappendiceal fat stranding (OR = 8.9; p < 0.001), and appendiceal mucosal hyperenhancement (OR = 8.7; p < 0.001). Of 35 patients whose initial clinical findings were reported as indeterminate, 28 (80%) had appendicitis. In this initially indeterminate group, using the standardized reporting system, radiologists assigned higher certainty scores (4 or 5) in 21 of the 28 patients with appendicitis (75%) and lower scores (1 or 2) in five of the seven patients without appendicitis (71%) (AUC = 0.90; p = 0.001). CONCLUSION Standardized reporting and grading of objective imaging findings correlated well with postoperative pathology and may decrease the number of CT findings reported as indeterminate for appendicitis. Prospective evaluation of this reporting system on a cohort of patients with clinically suspected appendicitis is currently under way. PMID:26001230

  3. A novel chaotic image encryption scheme using DNA sequence operations

    NASA Astrophysics Data System (ADS)

    Wang, Xing-Yuan; Zhang, Ying-Qian; Bao, Xue-Mei

    2015-10-01

    In this paper, we propose a novel image encryption scheme based on DNA (Deoxyribonucleic acid) sequence operations and chaotic system. Firstly, we perform bitwise exclusive OR operation on the pixels of the plain image using the pseudorandom sequences produced by the spatiotemporal chaos system, i.e., CML (coupled map lattice). Secondly, a DNA matrix is obtained by encoding the confused image using a kind of DNA encoding rule. Then we generate the new initial conditions of the CML according to this DNA matrix and the previous initial conditions, which can make the encryption result closely depend on every pixel of the plain image. Thirdly, the rows and columns of the DNA matrix are permuted. Then, the permuted DNA matrix is confused once again. At last, after decoding the confused DNA matrix using a kind of DNA decoding rule, we obtain the ciphered image. Experimental results and theoretical analysis show that the scheme is able to resist various attacks, so it has extraordinarily high security.

  4. NOTE: A method for controlling image acquisition in electronic portal imaging devices

    NASA Astrophysics Data System (ADS)

    Glendinning, A. G.; Hunt, S. G.; Bonnett, D. E.

    2001-02-01

    Certain types of camera-based electronic portal imaging devices (EPIDs) which initiate image acquisition based on sensing a change in video level have been observed to trigger unreliably at the beginning of dynamic multileaf collimation sequences. A simple, novel means of controlling image acquisition with an Elekta linear accelerator (Elekta Oncology Systems, Crawley, UK) is proposed which is based on illumination of a photodetector (ORP-12, Silonex Inc., Plattsburgh, NY, USA) by the electron gun of the accelerator. By incorporating a simple trigger circuit it is possible to derive a beam on/off status signal which changes at least 100 ms before any dose is measured by the accelerator. The status signal does not return to the beam-off state until all dose has been delivered and is suitable for accelerator pulse repetition frequencies of 50-400 Hz. The status signal is thus a reliable means of indicating the initiation and termination of radiation exposure, and thus controlling image acquisition of such EPIDs for this application.

  5. Multiresolution multiscale active mask segmentation of fluorescence microscope images

    NASA Astrophysics Data System (ADS)

    Srinivasa, Gowri; Fickus, Matthew; Kovačević, Jelena

    2009-08-01

    We propose an active mask segmentation framework that combines the advantages of statistical modeling, smoothing, speed and flexibility offered by the traditional methods of region-growing, multiscale, multiresolution and active contours respectively. At the crux of this framework is a paradigm shift from evolving contours in the continuous domain to evolving multiple masks in the discrete domain. Thus, the active mask framework is particularly suited to segment digital images. We demonstrate the use of the framework in practice through the segmentation of punctate patterns in fluorescence microscope images. Experiments reveal that statistical modeling helps the multiple masks converge from a random initial configuration to a meaningful one. This obviates the need for an involved initialization procedure germane to most of the traditional methods used to segment fluorescence microscope images. While we provide the mathematical details of the functions used to segment fluorescence microscope images, this is only an instantiation of the active mask framework. We suggest some other instantiations of the framework to segment different types of images.

  6. Performance of the dark energy camera liquid nitrogen cooling system

    NASA Astrophysics Data System (ADS)

    Cease, H.; Alvarez, M.; Alvarez, R.; Bonati, M.; Derylo, G.; Estrada, J.; Flaugher, B.; Flores, R.; Lathrop, A.; Munoz, F.; Schmidt, R.; Schmitt, R. L.; Schultz, K.; Kuhlmann, S.; Zhao, A.

    2014-01-01

    The Dark Energy Camera, the Imager and its cooling system was installed onto the Blanco 4m telescope at the Cerro Tololo Inter-American Observatory in Chile in September 2012. The imager cooling system is a LN2 two-phase closed loop cryogenic cooling system. The cryogenic circulation processing is located off the telescope. Liquid nitrogen vacuum jacketed transfer lines are run up the outside of the telescope truss tubes to the imager inside the prime focus cage. The design of the cooling system along with commissioning experiences and initial cooling system performance is described. The LN2 cooling system with the DES imager was initially operated at Fermilab for testing, then shipped and tested in the Blanco Coudé room. Now the imager is operating inside the prime focus cage. It is shown that the cooling performance sufficiently cools the imager in a closed loop mode, which can operate for extended time periods without maintenance or LN2 fills.

  7. A fast image encryption algorithm based on only blocks in cipher text

    NASA Astrophysics Data System (ADS)

    Wang, Xing-Yuan; Wang, Qian

    2014-03-01

    In this paper, a fast image encryption algorithm is proposed, in which the shuffling and diffusion is performed simultaneously. The cipher-text image is divided into blocks and each block has k ×k pixels, while the pixels of the plain-text are scanned one by one. Four logistic maps are used to generate the encryption key stream and the new place in the cipher image of plain image pixels, including the row and column of the block which the pixel belongs to and the place where the pixel would be placed in the block. After encrypting each pixel, the initial conditions of logistic maps would be changed according to the encrypted pixel's value; after encrypting each row of plain image, the initial condition would also be changed by the skew tent map. At last, it is illustrated that this algorithm has a faster speed, big key space, and better properties in withstanding differential attacks, statistical analysis, known plaintext, and chosen plaintext attacks.

  8. TU-H-206-01: An Automated Approach for Identifying Geometric Distortions in Gamma Cameras

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mann, S; Nelson, J; Samei, E

    2016-06-15

    Purpose: To develop a clinically-deployable, automated process for detecting artifacts in routine nuclear medicine (NM) quality assurance (QA) bar phantom images. Methods: An artifact detection algorithm was created to analyze bar phantom images as part of an ongoing QA program. A low noise, high resolution reference image was acquired from an x-ray of the bar phantom with a Philips Digital Diagnost system utilizing image stitching. NM bar images, acquired for 5 million counts over a 512×512 matrix, were registered to the template image by maximizing mutual information (MI). The MI index was used as an initial test for artifacts; lowmore » values indicate an overall presence of distortions regardless of their spatial location. Images with low MI scores were further analyzed for bar linearity, periodicity, alignment, and compression to locate differences with respect to the template. Findings from each test were spatially correlated and locations failing multiple tests were flagged as potential artifacts requiring additional visual analysis. The algorithm was initially deployed for GE Discovery 670 and Infinia Hawkeye gamma cameras. Results: The algorithm successfully identified clinically relevant artifacts from both systems previously unnoticed by technologists performing the QA. Average MI indices for artifact-free images are 0.55. Images with MI indices < 0.50 have shown 100% sensitivity and specificity for artifact detection when compared with a thorough visual analysis. Correlation of geometric tests confirms the ability to spatially locate the most likely image regions containing an artifact regardless of initial phantom orientation. Conclusion: The algorithm shows the potential to detect gamma camera artifacts that may be missed by routine technologist inspections. Detection and subsequent correction of artifacts ensures maximum image quality and may help to identify failing hardware before it impacts clinical workflow. Going forward, the algorithm is being deployed to monitor data from all gamma cameras within our health system.« less

  9. Attentional biases toward body images in males at high risk of muscle dysmorphia

    PubMed Central

    Jin, Xinhong; Zhou, Shi; Chang, Shuzhi; Li, Hui

    2018-01-01

    Objective Although research on muscle dysmorphia (MD), a body dysmorphic disorder subtype, has recently increased, the causes and mechanisms underlying this disorder remain unclear. Results from studies examining disorders associated with body image suggest the involvement of self-schema in biasing attention toward specific body information. The present study examined whether individuals at higher risk of MD also display attentional biases toward specific types of body images. Methods The validated Chinese version of the Muscle Appearance Satisfaction Scale was used to distinguish men at higher and lower risk of MD. Sixty-five adult Chinese men at higher (HRMD, n = 33) and lower risk of MD (LRMD, n = 32) performed a visual probe task. Initially, an image of a bodybuilder with either larger or smaller musculature was presented on one side of a central point, with a neutral image of a car exterior presented on the other side along the horizontal plane for 2,000 ms. The paired images were removed, and a visual target (a dot) was displayed in the location of one of the previously shown images. Participants were asked to indicate the location of the target, and their eye movements were recorded during the entire visual presentation. Participant reaction time and three eye movement measurements (gaze direction, first saccade latency, and first fixation duration) were recorded for use in determining attentional bias. Results The HRMD group revealed biases in orienting and maintaining their attention on images of bodybuilders with larger musculatures. Participants in this group consequently had a shorter reaction time in identifying the target that appeared at the location in which an image of a bodybuilder with a larger musculature had been previously displayed. They also directed their initial gaze more frequently, had shorter saccade latency, and had longer first fixation duration on images of bodybuilders with larger musculatures (all p < .0001). In comparison, the LRMD group had longer reaction times, slower attention orientation toward body images, and shorter fixation duration for images of bodybuilders with larger musculatures (all p < .0001), indicating weaker or mixed responses. Discussion Adult Chinese men at higher risk of MD displayed biases in orienting and maintaining their visual attention toward images of bodybuilders with larger musculatures, and these biases facilitated their information processing. These results suggest that development of MD may be due in part to attentional biases associated with established negative self-schema of specific body information. These findings provide insight into understanding and identifying the cognitive characteristics of MD in an Asian population. PMID:29362698

  10. Attentional biases toward body images in males at high risk of muscle dysmorphia.

    PubMed

    Jin, Xinhong; Jin, Yahong; Zhou, Shi; Yang, Shun-Nan; Chang, Shuzhi; Li, Hui

    2018-01-01

    Although research on muscle dysmorphia (MD), a body dysmorphic disorder subtype, has recently increased, the causes and mechanisms underlying this disorder remain unclear. Results from studies examining disorders associated with body image suggest the involvement of self-schema in biasing attention toward specific body information. The present study examined whether individuals at higher risk of MD also display attentional biases toward specific types of body images. The validated Chinese version of the Muscle Appearance Satisfaction Scale was used to distinguish men at higher and lower risk of MD. Sixty-five adult Chinese men at higher (HRMD, n  = 33) and lower risk of MD (LRMD, n  = 32) performed a visual probe task. Initially, an image of a bodybuilder with either larger or smaller musculature was presented on one side of a central point, with a neutral image of a car exterior presented on the other side along the horizontal plane for 2,000 ms. The paired images were removed, and a visual target (a dot) was displayed in the location of one of the previously shown images. Participants were asked to indicate the location of the target, and their eye movements were recorded during the entire visual presentation. Participant reaction time and three eye movement measurements (gaze direction, first saccade latency, and first fixation duration) were recorded for use in determining attentional bias. The HRMD group revealed biases in orienting and maintaining their attention on images of bodybuilders with larger musculatures. Participants in this group consequently had a shorter reaction time in identifying the target that appeared at the location in which an image of a bodybuilder with a larger musculature had been previously displayed. They also directed their initial gaze more frequently, had shorter saccade latency, and had longer first fixation duration on images of bodybuilders with larger musculatures (all p  < .0001). In comparison, the LRMD group had longer reaction times, slower attention orientation toward body images, and shorter fixation duration for images of bodybuilders with larger musculatures (all p  < .0001), indicating weaker or mixed responses. Adult Chinese men at higher risk of MD displayed biases in orienting and maintaining their visual attention toward images of bodybuilders with larger musculatures, and these biases facilitated their information processing. These results suggest that development of MD may be due in part to attentional biases associated with established negative self-schema of specific body information. These findings provide insight into understanding and identifying the cognitive characteristics of MD in an Asian population.

  11. Placental fetal stem segmentation in a sequence of histology images

    NASA Astrophysics Data System (ADS)

    Athavale, Prashant; Vese, Luminita A.

    2012-02-01

    Recent research in perinatal pathology argues that analyzing properties of the placenta may reveal important information on how certain diseases progress. One important property is the structure of the placental fetal stems. Analysis of the fetal stems in a placenta could be useful in the study and diagnosis of some diseases like autism. To study the fetal stem structure effectively, we need to automatically and accurately track fetal stems through a sequence of digitized hematoxylin and eosin (H&E) stained histology slides. There are many problems in successfully achieving this goal. A few of the problems are: large size of images, misalignment of the consecutive H&E slides, unpredictable inaccuracies of manual tracing, very complicated texture patterns of various tissue types without clear characteristics, just to name a few. In this paper we propose a novel algorithm to achieve automatic tracing of the fetal stem in a sequence of H&E images, based on an inaccurate manual segmentation of a fetal stem in one of the images. This algorithm combines global affine registration, local non-affine registration and a novel 'dynamic' version of the active contours model without edges. We first use global affine image registration of all the images based on displacement, scaling and rotation. This gives us approximate location of the corresponding fetal stem in the image that needs to be traced. We then use the affine registration algorithm "locally" near this location. At this point, we use a fast non-affine registration based on L2-similarity measure and diffusion regularization to get a better location of the fetal stem. Finally, we have to take into account inaccuracies in the initial tracing. This is achieved through a novel dynamic version of the active contours model without edges where the coefficients of the fitting terms are computed iteratively to ensure that we obtain a unique stem in the segmentation. The segmentation thus obtained can then be used as an initial guess to obtain segmentation in the rest of the images in the sequence. This constitutes an important step in the extraction and understanding of the fetal stem vasculature.

  12. Women and Society: The Mass Media.

    ERIC Educational Resources Information Center

    Busby, Linda J.

    Males and females have become vitally concerned with sex-role images in the mass media because of the ubiquitous nature of the media. Mass media, which have heavily penetrated Americans' lives, have the potential for initiating, reinforcing, or denying certain social values. In studies of various media, including magazine advertising, magazine…

  13. Digital food photography: Dietary surveillance and beyond

    USDA-ARS?s Scientific Manuscript database

    The method used for creating a database of approximately 20,000 digital images of multiple portion sizes of foods linked to the USDA's Food and Nutrient Database for Dietary Studies (FNDDS) is presented. The creation of this database began in 2002, and its development has spanned 10 years. Initially...

  14. INDICATOR OF EUTROPHICATION AND SEDIMENT LOAD: HYPERSPECTRAL TECHNIQUE FOR CONTINUOUS COVERAGE OF DEEP RIVERS

    EPA Science Inventory

    Remote sensing techniques were used to characterize and quantify spatial and temporal variation in water quality of the Great Miami River in Ohio. An initial feasibility study was conducted in the summer of 1999 using a non-imaging hand-held spectroradiometer to ascertain the pr...

  15. Managing and Creating an Image in the Interview: The Role of Interviewee Initial Impressions

    ERIC Educational Resources Information Center

    Swider, Brian W.; Barrick, Murray R.; Harris, T. Brad; Stoverink, Adam C.

    2011-01-01

    In employment interviews, individuals use impression management tactics to present themselves as suitable candidates to interviewers. However, not all impression management tactics, or the interviewees who employ them, are effective at positively influencing interview scores. Results of this study indicate that the relationship between impression…

  16. Alaska national hydrography dataset positional accuracy assessment study

    USGS Publications Warehouse

    Arundel, Samantha; Yamamoto, Kristina H.; Constance, Eric; Mantey, Kim; Vinyard-Houx, Jeremy

    2013-01-01

    Initial visual assessments Wide range in the quality of fit between features in NHD and these new image sources. No statistical analysis has been performed to actually quantify accuracy Determining absolute accuracy is cost prohibitive (must collect independent, well defined test points) Quantitative analysis of relative positional error is feasible.

  17. Student Images of Agriculture: Survey Highlights and Recommendations.

    ERIC Educational Resources Information Center

    Mallory, Mary E.; Sommer, Robert

    1986-01-01

    The high school students studied were unaware of the range of opportunities in agricultural careers. It was recommended that the University of California, Davis initiate a public relations campaign, with television advertising, movies, and/or public service announcements focusing on exciting, high-tech agricultural research and enterprise. (CT)

  18. HYPERSPECTRAL TECHNIQUE AS AN INDICATOR OF EUTROPHICATION AND SEDIMENT LOAD FOR DEEP RIVERS

    EPA Science Inventory

    Remote sensing techniques were used to characterize and quantify spatial and temporal variation in water quality of the Great Miami River in Ohio. An initial feasibility study was conducted in the summer of 1999 using a non-imaging hand-held spectroradiometer to ascertain the pre...

  19. Fast integrated intravascular photoacoustic/ultrasound catheter

    NASA Astrophysics Data System (ADS)

    Choi, Changhoon; Cho, Seunghee; Kim, Taehoon; Park, Sungjo; Park, Hyoeun; Kim, Jinmoo; Lee, Seunghoon; Kang, Yeonsu; Jang, Kiyuk; Kim, Chulhong

    2016-03-01

    In cardiology, a vulnerable plaque is considered to be a key subject because it is strongly related to atherosclerosis and acute myocardial infarction. Because conventional intravascular imaging devices exhibit several limitations with regard to vulnerable plaque detection, the need for an effective lipid imaging modality has been continuously suggested. Photoacoustic (PA) imaging is a medical imaging technique with a high level of ultrasound (US) resolution and strong optical contrast. In this study, we successfully developed an integrated intravascular photoacoustic/ultrasound (IV-PAUS) imaging system with a catheter diameter of 1.2 mm for lipid-rich atherosclerosis imaging. An Nd:YAG pulsed laser with an excitation wavelength of 1064 nm was utilized. IV-PAUS offers 5-mm depth penetration and axial and lateral PA imaging resolutions of 94 μm and 203 μm, respectively, as determined by imaging a 6-μm carbon fiber. We initially obtained 3-dimensional (3D) co-registered PA/US images of metal stents. Subsequently, we successfully obtained 3D coregistered PA/US ex vivo images using an iliac artery from a rabbit atherosclerosis model. Accordingly, lipid-rich plaques were sufficiently differentiated from normal tissue in the ex vivo experiment. We validated these findings histologically to confirm the lipid content.

  20. Comparison of arterial spin labeling registration strategies in the multi-center GENetic frontotemporal dementia initiative (GENFI).

    PubMed

    Mutsaerts, Henri J M M; Petr, Jan; Thomas, David L; De Vita, Enrico; Cash, David M; van Osch, Matthias J P; Golay, Xavier; Groot, Paul F C; Ourselin, Sebastien; van Swieten, John; Laforce, Robert; Tagliavini, Fabrizio; Borroni, Barbara; Galimberti, Daniela; Rowe, James B; Graff, Caroline; Pizzini, Francesca B; Finger, Elizabeth; Sorbi, Sandro; Castelo Branco, Miguel; Rohrer, Jonathan D; Masellis, Mario; MacIntosh, Bradley J

    2018-01-01

    To compare registration strategies to align arterial spin labeling (ASL) with 3D T1-weighted (T1w) images, with the goal of reducing the between-subject variability of cerebral blood flow (CBF) images. Multi-center 3T ASL data were collected at eight sites with four different sequences in the multi-center GENetic Frontotemporal dementia Initiative (GENFI) study. In a total of 48 healthy controls, we compared the following image registration options: (I) which images to use for registration (perfusion-weighted images [PWI] to the segmented gray matter (GM) probability map (pGM) (CBF-pGM) or M0 to T1w (M0-T1w); (II) which transformation to use (rigid-body or non-rigid); and (III) whether to mask or not (no masking, M0-based FMRIB software library Brain Extraction Tool [BET] masking). In addition to visual comparison, we quantified image similarity using the Pearson correlation coefficient (CC), and used the Mann-Whitney U rank sum test. CBF-pGM outperformed M0-T1w (CC improvement 47.2% ± 22.0%; P < 0.001), and the non-rigid transformation outperformed rigid-body (20.6% ± 5.3%; P < 0.001). Masking only improved the M0-T1w rigid-body registration (14.5% ± 15.5%; P = 0.007). The choice of image registration strategy impacts ASL group analyses. The non-rigid transformation is promising but requires validation. CBF-pGM rigid-body registration without masking can be used as a default strategy. In patients with expansive perfusion deficits, M0-T1w may outperform CBF-pGM in sequences with high effective spatial resolution. BET-masking only improves M0-T1w registration when the M0 image has sufficient contrast. 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:131-140. © 2017 International Society for Magnetic Resonance in Medicine.

Top