Guo, Shaolong; Zhang, Feihu; Zhang, Yong; Luan, Dianrong
2014-01-01
Through the polishing experiments of potassium dihydrogen phosphate (KDP) crystals based on deliquescent action, the effect of several major factors, including crystal's initial surface state, polishing time, and revolution of polishing plate, on material removal was researched. Under certain experimental conditions, the rules of material removal were reached, and experimental results are discussed, which lays the foundation for popularization and application of polishing technology for KDP crystals based on deliquescent action.
NASA Technical Reports Server (NTRS)
Vilnrotter, Victor A.
2012-01-01
Initial optical communications experiments with a Vertex polished aluminum panel have been described. The polished panel was mounted on the main reflector of the DSN's research antenna at DSS-13. The PSF was recorded via remotely controlled digital camera mounted on the subreflector structure. Initial PSF generated by Jupiter showed significant tilt error and some mechanical deformation. After upgrades, the PSF improved significantly, leading to much better concentration of light. Communications performance of the initial and upgraded panel structure were compared. After the upgrades, simulated PPM symbol error probability decreased by six orders of magnitude. Work is continuing to demonstrate closed-loop tracking of sources from zenith to horizon, and better characterize communications performance in realistic daytime background environments.
NASA Astrophysics Data System (ADS)
Czerwiec, T.; Tsareva, S.; Andrieux, A.; Bortolini, G. A.; Bolzan, P. H.; Castanet, G.; Gradeck, M.; Marcos, G.
2017-10-01
This communication focus on the evaporation of sessile water droplets on different states of austenitic stainless steel surfaces: mirror polished, mirror polished and aged and patterned by sputtering. The evolution of the contact angle and of the droplet diameter is presented as a function of time at room temperature. For all the surface states, a constant diameter regime (CCR) is observed. An important aging effect on the contact angle is measured on polished surfaces due to atmospheric contamination. The experimental observations are compared to a quasi-static evaporation model assuming spherical caps. The evolution of the droplet volume as a function of time is almost linear with the evaporation time for all the observed surfaces. This is in accordance with the model prediction for the CCR mode for small initial contact angles. In our experiments, the evaporation time is found to be linearly dependent on the initial contact angle. This dependence is not correctly described by the evaporation model
A new polishing process for large-aperture and high-precision aspheric surface
NASA Astrophysics Data System (ADS)
Nie, Xuqing; Li, Shengyi; Dai, Yifan; Song, Ci
2013-07-01
The high-precision aspheric surface is hard to be achieved due to the mid-spatial frequency error in the finishing step. The influence of mid-spatial frequency error is studied through the simulations and experiments. In this paper, a new polishing process based on magnetorheological finishing (MRF), smooth polishing (SP) and ion beam figuring (IBF) is proposed. A 400mm aperture parabolic surface is polished with this new process. The smooth polishing (SP) is applied after rough machining to control the MSF error. In the middle finishing step, most of low-spatial frequency error is removed by MRF rapidly, then the mid-spatial frequency error is restricted by SP, finally ion beam figuring is used to finish the surface. The surface accuracy is improved from the initial 37.691nm (rms, 95% aperture) to the final 4.195nm. The results show that the new polishing process is effective to manufacture large-aperture and high-precision aspheric surface.
Neutral ion sources in precision manufacturing
NASA Technical Reports Server (NTRS)
Fawcett, Steven C.; Drueding, Thomas W.
1994-01-01
Ion figuring of optical components is a relatively new technology that can alleviate some of the problems associated with traditional contact polishing. Because the technique is non contacting, edge distortions and rib structure print through do not occur. This initial investigation was aimed at determining the effect of ion figuring on surface roughness of previously polished or ductile ground ceramic optical samples. This is the first step in research directed toward the combination of a pre-finishing process (ductile grinding or polishing) with ion figuring to produce finished ceramic mirrors. The second phase of the project is focusing on the development of mathematical algorithms that will deconvolve the ion beam profile from the surface figure errors so that these errors can be successfully removed from the optical components. In the initial phase of the project, multiple, chemical vapor deposited silicon carbide (CVD SiC) samples were polished or ductile ground to specular or near-specular roughness. These samples were then characterized to determine topographic surface information. The surface evaluation consisted of stylus profilometry, interferometry, and optical and scanning electron microscopy. The surfaces, were ion machined to depths from 0-5 microns. The finished surfaces were characterized to evaluate the effects of the ion machining process with respect to the previous processing methods and the pre-existing subsurface damage. The development of the control algorithms for figuring optical components has been completed. These algorithms have been validated with simulations and future experiments have been planned to verify the methods. This paper will present the results of the initial surface finish experiments and the control algorithms simulations.
NASA Technical Reports Server (NTRS)
Khan, Gufran Sayeed; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian
2010-01-01
The presentation includes grazing incidence X-ray optics, motivation and challenges, mid spatial frequency generation in cylindrical polishing, design considerations for polishing lap, simulation studies and experimental results, future scope, and summary. Topics include current status of replication optics technology, cylindrical polishing process using large size polishing lap, non-conformance of polishin lap to the optics, development of software and polishing machine, deterministic prediction of polishing, polishing experiment under optimum conditions, and polishing experiment based on known error profile. Future plans include determination of non-uniformity in the polishing lap compliance, development of a polishing sequence based on a known error profile of the specimen, software for generating a mandrel polishing sequence, design an development of a flexible polishing lap, and computer controlled localized polishing process.
Simultaneous ion sputter polishing and deposition
NASA Technical Reports Server (NTRS)
Rutledge, S.; Banks, B.; Brdar, M.
1981-01-01
Results of experiments to study ion beam sputter polishing in conjunction with simultaneous deposition as a mean of polishing copper surfaces are presented. Two types of simultaneous ion sputter polishing and deposition were used in these experiments. The first type utilized sputter polishing simultaneous with vapor deposition, and the second type utilized sputter polishing simultaneous with sputter deposition. The etch and deposition rates of both techniques were studied, as well as the surface morphology and surface roughness.
Word Boundaries in L2 Speech: Evidence from Polish Learners of English
ERIC Educational Resources Information Center
Schwartz, Geoffrey
2016-01-01
Acoustic and perceptual studies investgate B2-level Polish learners' acquisition of second language (L2) English word-boundaries involving word-initial vowels. In production, participants were less likely to produce glottalization of phrase-medial initial vowels in L2 English than in first language (L1) Polish. Perception studies employing word…
Surface quality of silicon wafer improved by hydrodynamic effect polishing
NASA Astrophysics Data System (ADS)
Peng, Wenqiang; Guan, Chaoliang; Li, Shengyi
2014-08-01
Differing from the traditional pad polishing, hydrodynamic effect polishing (HEP) is non-contact polishing with the wheel floated on the workpiece. A hydrodynamic lubricated film is established between the wheel and the workpiece when the wheel rotates at a certain speed in HEP. Nanoparticles mixed with deionized water are employed as the polishing slurry, and with action of the dynamic pressure, nanoparticles with high chemisorption due to the high specific surface area can easily reacted with the surface atoms forming a linkage with workpiece surface. The surface atoms are dragged away when nanoparticles are transported to separate by the flow shear stress. The development of grand scale integration put extremely high requirements on the surface quality on the silicon wafer with surface roughness at subnanometer and extremely low surface damage. In our experiment a silicon sample was processed by HEP, and the surface topography before and after polishing was observed by the atomic force microscopy. Experiment results show that plastic pits and bumpy structures on the initial surface have been removed away clearly with the removal depth of 140nm by HEP process. The processed surface roughness has been improved from 0.737nm RMS to 0.175nm RMS(10μm×10μm) and the section profile shows peaks of the process surface are almost at the same height. However, the machining ripples on the wheel surface will duplicate on the silicon surface under the action of the hydrodynamic effect. Fluid dynamic simulation demonstrated that the coarse surface on the wheel has greatly influence on the distribution of shear stress and dynamic pressure on the workpiece surface.
AIBA as Free Radical Initiator for Abrasive-Free Polishing of Hard Disk Substrate
NASA Astrophysics Data System (ADS)
Lei, Hong; Ren, Xiaoyan
2015-04-01
In order to optimize the existing slurry for abrasive-free polishing (AFP) of a hard disk substrate, a water-soluble free radical initiator, 2,2'-azobis (2-methylpropionamidine) dihydrochloride (AIBA) was introduced into H2O2-based slurry in the present work. Polishing experiment results with AIBA in the H2O2 slurry indicate that the material removal rate (MRR) increases and the polished surface has a lower surface roughness. The mechanism of AIBA in AFP was investigated using electron spin-resonance spectroscopy and UV-Visible analysis, which showed that the concentration of hydroxyl radical (a stronger oxidizer than H2O2) in the slurry was enhanced in the present of AIBA. The structure of the film formed on the substrate surface was investigated by scanning electron microscopy, auger electron spectroscopy and electrochemical impedance spectroscopy technology, showing that a looser and porous oxide film was found on the hard disk substrate surface when treated with the H2O2-AIBA slurry. Furthermore, potentiodynamic polarization tests show that the H2O2-AIBA slurry has a higher corrosion current density, implying that a fast dissolution reaction can occur on the substrate surface. Therefore, we can conclude that the stronger oxidation ability, loose oxide film on the substrate surface, and the higher corrosion-wear rate of the H2O2-AIBA slurry lead to the higher MRR.
[Bogdan Suchodolski--initiator and editor-in-chief of the publication History of Polish Science].
Kuźnicka, Barbara; Kuźnicki, Leszek
2011-01-01
Among numerous and distinguished author's and editorial works of Bogdan Suchodolski a particular value presents a publication in eight volumes entitled 'History of Polish Science' (including two biographical and bibliographic volumes), which was published in the years 1970-1992 on Professor's own initiative and edited by himself. This is the first synthesis of the history of science in Poland, from the beginning of the Middle Ages till the present time (to 1952). In the conception of the initiator and editor the work presents the development of scientific thought and achievements of the scholars in relation to national culture and in connexions with the trends in science in the world. 'History of Polish Science' is the work written by several dozen authors, representing different domains of the knowledge. Scientific, organizational and editorial patronate was possible by dint of History of Science and Technology Establishment of Polish Academy of Sciences (presently the Institute for the History of Science of Polish Academy of Sciences), which was managed by Bogdan Suchodolski.
Structural considerations for fabrication and mounting of the AXAF HRMA optics
NASA Technical Reports Server (NTRS)
Cohen, Lester M.; Cernoch, Larry; Mathews, Gary; Stallcup, Michael
1990-01-01
A methodology is described which minimizes optics distortion in the fabrication, metrology, and launch configuration phases. The significance of finite element modeling and breadboard testing is described with respect to performance analyses of support structures and material effects in NASA's AXAF X-ray optics. The paper outlines the requirements for AXAF performance, optical fabrication, metrology, and glass support fixtures, as well as the specifications for mirror sensitivity and the high-resolution mirror assembly. Analytical modeling of the tools is shown to coincide with grinding and polishing experiments, and is useful for designing large-area polishing and grinding tools. Metrological subcomponents that have undergone initial testing show evidence of meeting force requirements.
Deterministic Computer-Controlled Polishing Process for High-Energy X-Ray Optics
NASA Technical Reports Server (NTRS)
Khan, Gufran S.; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian
2010-01-01
A deterministic computer-controlled polishing process for large X-ray mirror mandrels is presented. Using tool s influence function and material removal rate extracted from polishing experiments, design considerations of polishing laps and optimized operating parameters are discussed
[About the genesis of the first Polish local research ethics committee].
Paprocka-Lipinska, Anna
2014-12-01
From the moment in which the development of medicine became necessary experimental research involving human subjects, the question arose about the ethical limits and limitations of the experiment. The turning point was the year 1947. The Nuremberg Code was formulated after the disclosure of pseudo-medical experiments involving human subjects during the Second World War. In 1964, the medical world accepted the Declaration of Helsinki, which, however, did not prevent abuses and it became necessary to appoint independent ethics committees supervising and enforcing the application of ethics in biomedical experiments. In Poland in the 60's and 70's started a discussion on the ethical rules related to conduct of research involving humans. The initiators of the appointment of bioethics committees were professors of medicine, inspiring experiences of their Western colleagues. It was difficult for reasons of political ideologies to convince the authorities to use the best of western solutions. This paper attempts to describe the circumstances connected with the appointment in 1979 at the Medical University of Gdansk, the first Polish bioethics committee.
Polishing mechanism of light-initiated dental composite: Geometric optics approach.
Chiang, Yu-Chih; Lai, Eddie Hsiang-Hua; Kunzelmann, Karl-Heinz
2016-12-01
For light-initiated dental hybrid composites, reinforcing particles are much stiffer than the matrix, which makes the surface rugged after inadequate polish and favors bacterial adhesion and biofilm redevelopment. The aim of the study was to investigate the polishing mechanism via the geometric optics approach. We defined the polishing abilities of six instruments using the obtained gloss values through the geometric optics approach (micro-Tri-gloss with 20°, 60°, and 85° measurement angles). The surface texture was validated using a field emission scanning electron microscope (FE-SEM). Based on the gloss values, we sorted polishing tools into three abrasive levels, and proposed polishing sequences to test the hypothesis that similar abrasive levels would leave equivalent gloss levels on dental composites. The three proposed, tested polishing sequences included: S1, Sof-Lex XT coarse disc, Sof-Lex XT fine disc, and OccluBrush; S2, Sof-Lex XT coarse disc, Prisma Gloss polishing paste, and OccluBrush; and S3, Sof-Lex XT coarse disc, Enhance finishing cups, and OccluBrush. S1 demonstrated significantly higher surface gloss than the other procedures (p < 0.05). The surface textures (FE-SEM micrographs) correlated well with the obtained gloss values. Nominally similar abrasive abilities did not result in equivalent polish levels, indicating that the polishing tools must be evaluated and cannot be judged based on their compositions or abrasive sizes. The geometric optic approach is an efficient and nondestructive method to characterize the polished surface of dental composites. Copyright © 2015. Published by Elsevier B.V.
Otolith Trace Element Chemistry of Juvenile Black Rockfish
NASA Astrophysics Data System (ADS)
Hardin, W.; Bobko, S. J.; Jones, C. M.
2002-12-01
In the summer of 1997 we collected young-of -the-year (YOY) black rockfish, Sebastes melanops, from floating docks and seagrass beds in Newport and Coos Bay, Oregon. Otoliths were extracted from randomly selected fish, sectioned and polished under general laboratory conditions, and cleaned in a class 100 clean room. We used Laser Ablation - Inductively Coupled Mass Spectrometry (LA-ICPMS) to analyze elemental composition of the estuarine phase of the otoliths. While we observed differences in Mn/Ca ratios between the two estuaries, there was no statistical difference in otolith trace element chemistry ratios between estuaries using MANOVA. To determine if laboratory processing of otoliths might have impeded us from detecting differences in otolith chemistry, we conducted a second experiment. Right and left otoliths from 10 additional Coos Bay fish were randomly allocated to two processing methods. The first method was identical to our initial otolith processing, sectioning and polishing under normal laboratory conditions. In the second method, polishing was done in the clean room. For both methods otoliths went through a final cleaning in the clean room and analyzed with LA-ICPMS. While we did not detect statistical differences in element ratios between the two methods, otoliths polished outside the clean room had much higher variances. This increased variance might have lowered our ability to detect differences in otolith chemistry between estuaries. Based on our results, we recommend polishing otoliths under clean room conditions to reduce contamination.
Educational Civil Experiment--A Story of a Particular Radical Housing Estate
ERIC Educational Resources Information Center
Matysek-Imielinska, Magdalena
2016-01-01
In the 1920s,in the environment of emerging brutal capitalism, exclusion and ghetto benches, on the initiative of avant-garde architects from the Praesens group and Polish socialists built a housing estate in Zoliborz, the ambition of which was to teach people how to dwell. Soon it turned out that the founders of the housing cooperative were, as…
ERIC Educational Resources Information Center
Jaroszynska-Kirchmann, Anna D.
2008-01-01
"Ameryka-Echo" was one of the most popular Polish-language weeklies, published in the United States between 1889 and 1972. Its founder and owner, Antoni A. Paryski, consciously sought to transplant ideas of Polish Positivism to the Polish-American immigrant communities in the United States. Reading was a central concept of…
Chen, Shaoshan; Li, Shengyi; Hu, Hao; Li, Qi; Tie, Guipeng
2014-11-01
A new nonaqueous and abrasive-free magnetorheological finishing (MRF) method is adopted for processing potassium dihydrogen phosphate (KDP) crystal due to its low hardness, high brittleness, temperature sensitivity, and water solubility. This paper researches the influence of structural characteristics on the surface roughness of MRF-finished KDP crystal. The material removal by dissolution is uniform layer by layer when the polishing parameters are stable. The angle between the direction of the polishing wheel's linear velocity and the initial turning lines will affect the surface roughness. If the direction is perpendicular to the initial turning lines, the polishing can remove the lines. If the direction is parallel to the initial turning lines, the polishing can achieve better surface roughness. The structural characteristic of KDP crystal is related to its internal chemical bonds due to its anisotropy. During the MRF finishing process, surface roughness will be improved if the structural characteristics of the KDP crystal are the same on both sides of the wheel. The processing results of (001) plane crystal show we can get the best surface roughness (RMS of 0.809 nm) if the directions of cutting and MRF polishing are along the (110) direction.
Bonner, Brian C; Young, Linda; Smith, Patricia A; McCombes, Wendy; Clarkson, Jan E
2005-01-01
Background To investigate, within general dental practice, patients' and vocational dental practitioners' (VDP) attitudes towards the benefits and costs of a simple scale and polish and to compare the experience of using manual versus ultrasonic instruments to scale teeth. Methods 28 VDPs and 420 patients participated. Patients were randomly allocated to either group. Patients' and VDPs' attitudes towards, and experience of, the scale and polish were elicited by means of self-administered questionnaires. Results The majority of patients (99%) believed a scale and polish was beneficial. VDPs considered ultrasonic treatment to be appropriate on significantly more occasions than they did for manual scale and polish (P < 0.001). Patient discomfort: with ultrasonic scaling 69.2% felt 'a little uncomfortable' or worse compared with 60% of those undergoing manual treatment (P = 0.072). VDPs considered treatment charges were appropriate for 77% of patients. Conclusion Routine scaling and polishing is considered beneficial by both patients and vocational trainees. The majority of patients, regardless of treatment method, experience some degree of discomfort when undergoing a scale and polish. VDPs showed a preference for the ultrasonic treatment method. PMID:15975140
Study on chemical mechanical polishing of silicon wafer with megasonic vibration assisted.
Zhai, Ke; He, Qing; Li, Liang; Ren, Yi
2017-09-01
Chemical mechanical polishing (CMP) is the primary method to realize the global planarization of silicon wafer. In order to improve this process, a novel method which combined megasonic vibration to assist chemical mechanical polishing (MA-CMP) is developed in this paper. A matching layer structure of polishing head was calculated and designed. Silicon wafers are polished by megasonic assisted chemical mechanical polishing and traditional chemical mechanical polishing respectively, both coarse polishing and precision polishing experiments were carried out. With the use of megasonic vibration, the surface roughness values Ra reduced from 22.260nm to 17.835nm in coarse polishing, and the material removal rate increased by approximately 15-25% for megasonic assisted chemical mechanical polishing relative to traditional chemical mechanical polishing. Average Surface roughness values Ra reduced from 0.509nm to 0.387nm in precision polishing. The results show that megasonic assisted chemical mechanical polishing is a feasible method to improve polishing efficiency and surface quality. The material removal and finishing mechanisms of megasonic vibration assisted polishing are investigated too. Copyright © 2017 Elsevier B.V. All rights reserved.
Ageing and Learning Experiences: The Perspective of a Polish Senior Immigrant in Sweden
ERIC Educational Resources Information Center
Rawinski, Malgorzata Malec
2017-01-01
The general aim of this paper is to present some insights into Polish senior immigrants in Sweden. In particular, it seeks to identify and illustrate the important contribution of previous generations of Polish senior immigrants in building on the diverse culture, traditions and values of the Polish community (Polonia) in Sweden. The paper…
Chen, Shaoshan; Li, Shengyi; Peng, Xiaoqiang; Hu, Hao; Tie, Guipeng
2015-02-20
A new nonaqueous and abrasive-free magnetorheological finishing (MRF) method is adopted for processing a KDP crystal. MRF polishing is easy to result in the embedding of carbonyl iron (CI) powders; meanwhile, Fe contamination on the KDP crystal surface will affect the laser induced damage threshold seriously. This paper puts forward an appropriate MRF polishing process to avoid the embedding. Polishing results show that the embedding of CI powders can be avoided by controlling the polishing parameters. Furthermore, on the KDP crystal surface, magnetorheological fluids residua inevitably exist after polishing and in which the Fe contamination cannot be removed completely by initial ultrasonic cleaning. To solve this problem, a kind of ion beam figuring (IBF) polishing is introduced to remove the impurity layer. Then the content of Fe element contamination and the depth of impurity elements are measured by time of flight secondary ion mass spectrometry. The measurement results show that there are no CI powders embedding in the MRF polished surface and no Fe contamination after the IBF polishing process, respectively. That verifies the feasibility of MRF polishing-IBF polishing (cleaning) for processing a KDP crystal.
Improvement of magnetorheological finishing surface quality by nanoparticle jet polishing
NASA Astrophysics Data System (ADS)
Peng, Wenqiang; Li, Shengyi; Guan, Chaoliang; Shen, Xinmin; Dai, Yifan; Wang, Zhuo
2013-04-01
Nanoparticle jet polishing (NJP) is presented as a posttreatment to remove magnetorheological finishing (MRF) marks. In the NJP process the material is removed by chemical impact reaction, and the material removal rate of convex part is larger than that of the concave part. Smoothing thus can progress automatically in the NJP process. In the experiment, a silica glass sample polished by MRF was polished by NJP. Experiment results showed the MRF marks were removed clearly. The uniform polishing process shows that the NJP process can remove the MRF marks without destroying the original surface figure. The surface root-mean-square roughness is improved from 0.72 to 0.41 nm. power spectral density analysis indicates the surface quality is improved, and the experimental result validates effective removal of MRF marks by NJP.
Laser polishing of 3D printed mesoscale components
NASA Astrophysics Data System (ADS)
Bhaduri, Debajyoti; Penchev, Pavel; Batal, Afif; Dimov, Stefan; Soo, Sein Leung; Sten, Stella; Harrysson, Urban; Zhang, Zhenxue; Dong, Hanshan
2017-05-01
Laser polishing of various engineered materials such as glass, silica, steel, nickel and titanium alloys, has attracted considerable interest in the last 20 years due to its superior flexibility, operating speed and capability for localised surface treatment compared to conventional mechanical based methods. The paper initially reports results from process optimisation experiments aimed at investigating the influence of laser fluence and pulse overlap parameters on resulting workpiece surface roughness following laser polishing of planar 3D printed stainless steel (SS316L) specimens. A maximum reduction in roughness of over 94% (from ∼3.8 to ∼0.2 μm Sa) was achieved at the optimised settings (fluence of 9 J/cm2 and overlap factors of 95% and 88-91% along beam scanning and step-over directions respectively). Subsequent analysis using both X-ray photoelectron spectroscopy (XPS) and glow discharge optical emission spectroscopy (GDOES) confirmed the presence of surface oxide layers (predominantly consisting of Fe and Cr phases) up to a depth of ∼0.5 μm when laser polishing was performed under normal atmospheric conditions. Conversely, formation of oxide layers was negligible when operating in an inert argon gas environment. The microhardness of the polished specimens was primarily influenced by the input thermal energy, with greater sub-surface hardness (up to ∼60%) recorded in the samples processed with higher energy density. Additionally, all of the polished surfaces were free of the scratch marks, pits, holes, lumps and irregularities that were prevalent on the as-received stainless steel samples. The optimised laser polishing technology was consequently implemented for serial finishing of structured 3D printed mesoscale SS316L components. This led to substantial reductions in areal Sa and St parameters by 75% (0.489-0.126 μm) and 90% (17.71-1.21 μm) respectively, without compromising the geometrical accuracy of the native 3D printed samples.
Study on optical polishing experiment of zerodur mirror
NASA Astrophysics Data System (ADS)
Wang, Huijun; Li, Hang; Wang, Peng; Guo, Wen; Wang, Yonggang; Du, Yan; Dong, Huiwen
2014-08-01
A zerodur mirror whose aperture is 900mm is chosen to be the primary mirror of an optical system. The mirror is polished by rapid polishing and precision polishing methods relatively. The final surface figures of the mirror are as follows: the peak-to-valley value (P-V value) is 0.204λ (λ=632.8nm), and the root-mean-square value (RMS value) is 0.016λ, which meet the requirement of the optical system. The results show that the polishing process is feasible.
Effect of the Polishing Procedures on Color Stability and Surface Roughness of Composite Resins
Schmitt, Vera Lucia; Puppin-Rontani, Regina Maria; Naufel, Fabiana Scarparo; Nahsan, Flávia Pardo Salata; Alexandre Coelho Sinhoreti, Mário; Baseggio, Wagner
2011-01-01
Objectives. To evaluate the polishing procedures effect on color stability and surface roughness of composite resins. Methods. Specimens were distributed into 6 groups: G1: Filtek Supreme XT + PoGo; G2: Filtek Supreme XT + Sof-Lex; G3: Filtek Supreme XT + no polishing; G4: Amelogen + PoGo; G5: Amelogen + Sof-Lex.; G6: Amelogen + no polishing. Initial color values were evaluated using the CIELab scale. After polishing, surface roughness was evaluated and the specimens were stored in coffee solution at 37°C for 7 days. The final color measurement and roughness were determined. Results. Sof-Lex resulted in lower staining. Amelogen showed the highest roughness values than Filtek Supreme on baseline and final evaluations regardless of the polishing technique. Filtek Supreme polished with PoGo showed the lowest roughness values. All groups presented discoloration after storage in coffee solution, regardless of the polishing technique. Conclusion. Multiple-step polishing technique provided lower degree of discoloration for both composite resins. The final surface texture is material and technique dependent. PMID:21991483
CVD diamond substrate for microelectronics. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burden, J.; Gat, R.
1996-11-01
Chemical Vapor Deposition (CVD) of diamond films has evolved dramatically in recent years, and commercial opportunities for diamond substrates in thermal management applications are promising. The objective of this technology transfer initiative (TTI) is for Applied Science and Technology, Inc. (ASTEX) and AlliedSignal Federal Manufacturing and Technologies (FM&T) to jointly develop and document the manufacturing processes and procedures required for the fabrication of multichip module circuits using CVD diamond substrates, with the major emphasis of the project concentrating on lapping/polishing prior to metallization. ASTEX would provide diamond films for the study, and FM&T would use its experience in lapping, polishing,more » and substrate metallization to perform secondary processing on the parts. The primary goal of the project was to establish manufacturing processes that lower the manufacturing cost sufficiently to enable broad commercialization of the technology.« less
NASA Astrophysics Data System (ADS)
Sun, Zhiyuan; Guo, Bing; Rao, Zhimin; Zhao, Qingliang
2014-08-01
In consideration of the excellent property of SiC, the ground micro-structured surface quality is hard to meet the requirement - consequently the ultrasonic vibration assisted polishing (UVAP) of micro-structures of molds is proposed in this paper. Through the orthogonal experiment, the parameters of UVAP of micro-structures were optimized. The experimental results show that, abrasive polishing process, the effect of the workpiece feed rate on the surface roughness (Ra), groove tip radius (R) and material removal rate (MRR) of micro-structures is significant. While, the UVAP, the most significant effect factor for Ra, R and MRR is the ultrasonic amplitude of the ultrasonic vibration. In addition, within the scope of the polishing process parameters selected by preliminary experiments, ultrasonic amplitude of 2.5μm, polishing force of 0.5N, workpiece feed rate of 5 mm·min-1, polishing wheel rotational speed of 50rpm, polishing time of 35min, abrasive size of 100nm and the polishing liquid concentration of 15% is the best technology of UVAP of micro-structures. Under the optimal parameters, the ground traces on the micro-structured surface were removed efficiently and the integrity of the edges of the micro-structure after grinding was maintained efficiently.
In vitro cytotoxicity of traditional versus contemporary dental ceramics.
Messer, Regina L W; Lockwood, Petra E; Wataha, John C; Lewis, Jill B; Norris, Samuel; Bouillaguet, Serge
2003-11-01
The biocompatibility of new dental ceramics has not been assessed with the same scrutiny as has been applied to alloys and composites. Yet, the biocompatibility of ceramics is critical to the long-term success of dental prostheses because ceramics are in close contact with oral tissues for extended periods. Five dental ceramics (2 traditional feldspathic veneer porcelains [Vita Omega and Duceragold], 2 lithium disilicate pressable materials [Stylepress and Empress-2], and a pressable leucite-based material [Empress-1]) were tested for their ability to alter cellular mitochondrial dehydrogenase activity after fabrication using a tetrazolium assay, after aging for 2 weeks in a biologic solution and after post-aging polishing with either a fine diamond or diamond polishing paste. Cellular responses were compared with polytetrafluoroethylene controls (analysis of variance, Tukey pairwise post-hoc comparison, alpha=.05). The feldspathic porcelains caused only mild (<25% of controls) mitochondrial suppression regardless of aging or polishing. The pressable leucite-based material initially caused a 5% stimulation (not significant) of mitochondrial activity, which decreased significantly (P<.05) by 30% with aging to levels comparable to the feldspathic porcelains, and did not change with polishing. Both lithium disilicate materials caused an initial suppression of mitochondrial activity that decreased significantly with aging, but Empress-2 was severely cytotoxic initially (<20% of controls, P<.01), and became more cytotoxic again after polishing. Stylepress was less cytotoxic initially (85% of controls, not significant) and did not become cytotoxic again after polishing. Dental ceramics are not equivalent in their in vitro biologic effects, even within the same class of material, and biologic safety should not be assumed. Most ceramics caused only mild in vitro suppression of cell function to levels that would be acceptable on the basis of standards used to evaluate alloys and composites. However, 1 Li-disilicate material (Empress-2) exhibited cytotoxicity that would not be deemed biologically acceptable on the basis of prevailing empirical standards for dental alloys and composites.
Investigation of contact pressure and influence function model for soft wheel polishing.
Rao, Zhimin; Guo, Bing; Zhao, Qingliang
2015-09-20
The tool influence function (TIF) is critical for calculating the dwell-time map to improve form accuracy. We present the TIF for the process of computer-controlled polishing with a soft polishing wheel. In this paper, the static TIF was developed based on the Preston equation. The pressure distribution was verified by the real removal spot section profiles. According to the experiment measurements, the pressure distribution simulated by Hertz contact theory was much larger than the real contact pressure. The simulated pressure distribution, which was modeled by the Winkler elastic foundation for a soft polishing wheel, matched the real contact pressure. A series of experiments was conducted to obtain the removal spot statistical properties for validating the relationship between material removal and processing time and contact pressure and relative velocity, along with calculating the fitted parameters to establish the TIF. The developed TIF predicted the removal character for the studied soft wheel polishing.
Tooth Surface Comparison after Air Polishing and Rubber Cup: A Scanning Electron Microscopy Study.
Camboni, Sara; Donnet, Marcel
2016-03-01
To demonstrate, using microscopic observations, the difference between two well-known oral prophylaxis techniques: polishing paste and air polishing. The observations were performed on human enamel. Enamel samples were obtained from plaque-rich human teeth extracted for orthodontic or clinical purposes. In order to allow a reliable comparison between different applications, each enamel sample was divided into two parts: one underwent air-polishing, whereas polishing paste was applied to the other. AIR-FLOW® Master was selected together with AIR-FLOW® PLUS for the prophylaxis powder application. For the polishing-paste application, several different pastes where used, including Cleanic®, CCS®, Proxyt®, and SuperPolish. A comparative test control was also used by cleaning the enamel with sodium hypochlorite (6%). The enamel treated with AIR-FLOW PLUS showed a similar surface when compared to the control enamel; however, there was complete cleaning down to the tooth microstructure. On the other hand, use of the polishing paste resulted in an enamel surface that appeared abraded and flattened. Moreover, some of the natural irregular enamel surfaces demonstrated some filling in with debris. AIR-FLOW PLUS powder was able to more deeply clean without creating any damage to the enamel, making it suitable for regular cleaning treatments. The polishing pastes were found to abrade the enamel surface, to flatten it, and deposit debris into the microcavities. Both methods having different mechanical effects can therefore be considered as complementary, in that some patients experience a sense of "roughness" following a cleaning. A clinical recommendation for this experience would be to use the air polish first to clean the enamel surface, and follow with a little polishing paste to smooth the surface, if required.
Optimization and application of influence function in abrasive jet polishing.
Li, Zhaoze; Li, Shengyi; Dai, Yifan; Peng, Xiaoqiang
2010-05-20
We analyze the material removal mechanism of abrasive jet polishing (AJP) technology, based on the fluid impact dynamics theory. Combined with the computational fluid dynamics simulation and process experiments, influence functions at different impingement angles are obtained, which are not of a regular Gaussian shape and are unfit for the corrective figuring of optics. The influence function is then optimized to obtain an ideal Gaussian shape by rotating the oblique nozzle, and its stability is validated through a line scanning experiment. The fluctuation of the influence function can be controlled within +/-5%. Based on this, we build a computed numerically controlled experimental system for AJP, and one flat BK7 optical glass with a diameter of 20mm is polished. After two iterations of polishing, the peak-to-valley value decreases from 1.43lambda (lambda=632.8nm in this paper) to 0.294lambda, and the rms value decreases from 0.195lambda to 0.029lambda. The roughness of this polished surface is within 2nm. The experimental result indicates that the optimized influence function is suitable for precision optics figuring and polishing.
Vanishing Act: Experiments on Fission Track Annealing in Monazite
NASA Astrophysics Data System (ADS)
Shipley, N. K.; Fayon, A. K.
2006-12-01
To determine the viability of monazite as a low temperature thermochronometer, we conducted fission track annealing experiments under isothermal conditions. These experiments evaluated the effects of uranium concentration and zoning on annealing rates. Fission track annealing rates in monazite were also compared to those in Durango apatite. Preliminary results indicate that monazite grains with higher initial track densities anneal at faster rates than those with low initial densities and that fission tracks in monazite anneal at a faster rate than those in apatite. Monazite sand grains were selected from a placer sand deposit, mounted in teflon, and polished. Grains were imaged with electron backscattering to characterize zoning patterns and variations in uranium concentration. Monazite grain mounts were etched in boiling 37% HCl for 50 minutes and fission track densities were determined using standard fission track counting techniques. Durango apatite was etched in 5N HNO3 at room temperature for 20 seconds. After the initial track densities were determined, mounts in one group were annealed at 150 ° C for 1to 6 h. The mounts in a second group were annealed at 200 ° C for 2 hour periods along with mounts of Durango apatite grains. All grains were re-polished prior to each anneal. Upon completion of the experiment, backscatter images were taken of grains from which fission track counts were obtained to verify continuance of concentric zoning. Results of these experiments indicate that annealing rates of fission tracks in monazite vary as a function of uranium concentration. Uranium concentration was constrained on the basis of zoning patterns obtained from electron backscatter images. Fission track densities in grains with initial track densities of approximately 2.4 × 106 tracks/cm2 were reduced at average rate of 16% every two hours. In contrast, track densities in grains with initial track densities of approximately 1.6 × 106 tracks/cm2 average 4.6% density reduction every two hours. In both cases, track density reduction in monazite was faster than the rate of 0.1 % every two hours obtained for apatite. This would indicate that fission track annealing occurs at a lower temperature in monazite than in apatite. Thus monazite would be useful as a low temperature chronometer for determining cooling histories in recently exhumed rocks.
Quantitative Analysis of Nail Polish Remover Using Nuclear Magnetic Resonance Spectroscopy Revisited
ERIC Educational Resources Information Center
Hoffmann, Markus M.; Caccamis, Joshua T.; Heitz, Mark P.; Schlecht, Kenneth D.
2008-01-01
Substantial modifications are presented for a previously described experiment using nuclear magnetic resonance (NMR) spectroscopy to quantitatively determine analytes in commercial nail polish remover. The revised experiment is intended for a second- or third-year laboratory course in analytical chemistry and can be conducted for larger laboratory…
Suratwala, Tayyab; Steele, Rusty; Feit, Michael; Dylla-Spears, Rebecca; Desjardin, Richard; Mason, Dan; Wong, Lana; Geraghty, Paul; Miller, Phil; Shen, Nan
2014-01-01
Convergent Polishing is a novel polishing system and method for finishing flat and spherical glass optics in which a workpiece, independent of its initial shape (i.e., surface figure), will converge to final surface figure with excellent surface quality under a fixed, unchanging set of polishing parameters in a single polishing iteration. In contrast, conventional full aperture polishing methods require multiple, often long, iterative cycles involving polishing, metrology and process changes to achieve the desired surface figure. The Convergent Polishing process is based on the concept of workpiece-lap height mismatch resulting in pressure differential that decreases with removal and results in the workpiece converging to the shape of the lap. The successful implementation of the Convergent Polishing process is a result of the combination of a number of technologies to remove all sources of non-uniform spatial material removal (except for workpiece-lap mismatch) for surface figure convergence and to reduce the number of rogue particles in the system for low scratch densities and low roughness. The Convergent Polishing process has been demonstrated for the fabrication of both flats and spheres of various shapes, sizes, and aspect ratios on various glass materials. The practical impact is that high quality optical components can be fabricated more rapidly, more repeatedly, with less metrology, and with less labor, resulting in lower unit costs. In this study, the Convergent Polishing protocol is specifically described for fabricating 26.5 cm square fused silica flats from a fine ground surface to a polished ~λ/2 surface figure after polishing 4 hr per surface on a 81 cm diameter polisher. PMID:25489745
Strain-free polished channel-cut crystal monochromators: a new approach and results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasman, Elina; Montgomery, Jonathan; Huang, XianRong
The use of channel-cut crystal monochromators has been traditionally limited to applications that can tolerate the rough surface quality from wet etching without polishing. We have previously presented and discussed the motivation for producing channel cut crystals with strain-free polished surfaces [1]. Afterwards, we have undertaken an effort to design and implement an automated machine for polishing channel-cut crystals. The initial effort led to inefficient results. Since then, we conceptualized, designed, and implemented a new version of the channel-cut polishing machine, now called C-CHiRP (Channel-Cut High Resolution Polisher), also known as CCPM V2.0. The new machine design no longer utilizesmore » Figure-8 motion that mimics manual polishing. Instead, the polishing is achieved by a combination of rotary and linear functions of two coordinated motion systems. Here we present the new design of C-CHiRP, its capabilities and features. Multiple channel-cut crystals polished using the C-CHiRP have been deployed into several beamlines at the Advanced Photon Source (APS). We present the measurements of surface finish, flatness, as well as topography results obtained at 1-BM of APS, as compared with results typically achieved when polishing flat-surface monochromator crystals using conventional polishing processes. Limitations of the current machine design, capabilities and considerations for strain-free polishing of highly complex crystals are also discussed, together with an outlook for future developments and improvements.« less
Dwell time algorithm based on the optimization theory for magnetorheological finishing
NASA Astrophysics Data System (ADS)
Zhang, Yunfei; Wang, Yang; Wang, Yajun; He, Jianguo; Ji, Fang; Huang, Wen
2010-10-01
Magnetorheological finishing (MRF) is an advanced polishing technique capable of rapidly converging to the required surface figure. This process can deterministically control the amount of the material removed by varying a time to dwell at each particular position on the workpiece surface. The dwell time algorithm is one of the most important key techniques of the MRF. A dwell time algorithm based on the1 matrix equation and optimization theory was presented in this paper. The conventional mathematical model of the dwell time was transferred to a matrix equation containing initial surface error, removal function and dwell time function. The dwell time to be calculated was just the solution to the large, sparse matrix equation. A new mathematical model of the dwell time based on the optimization theory was established, which aims to minimize the 2-norm or ∞-norm of the residual surface error. The solution meets almost all the requirements of precise computer numerical control (CNC) without any need for extra data processing, because this optimization model has taken some polishing condition as the constraints. Practical approaches to finding a minimal least-squares solution and a minimal maximum solution are also discussed in this paper. Simulations have shown that the proposed algorithm is numerically robust and reliable. With this algorithm an experiment has been performed on the MRF machine developed by ourselves. After 4.7 minutes' polishing, the figure error of a flat workpiece with a 50 mm diameter is improved by PV from 0.191λ(λ = 632.8 nm) to 0.087λ and RMS 0.041λ to 0.010λ. This algorithm can be constructed to polish workpieces of all shapes including flats, spheres, aspheres, and prisms, and it is capable of improving the polishing figures dramatically.
Kim, Dong-Woo; Cho, Myeong-Woo; Seo, Tae-Il; Shin, Young-Jae
2008-01-01
Recently, the magnetorheological (MR) polishing process has been examined as a new ultra-precision polishing technology for micro parts in MEMS applications. In the MR polishing process, the magnetic force plays a dominant role. This method uses MR fluids which contains micro abrasives as a polishing media. The objective of the present research is to shed light onto the material removal mechanism under various slurry conditions for polishing and to investigate surface characteristics, including shape analysis and surface roughness measurement, of spots obtained from the MR polishing process using alumina abrasives. A series of basic experiments were first performed to determine the optimum polishing conditions for BK7 glass using prepared slurries by changing the process parameters, such as wheel rotating speed and electric current. Using the obtained results, groove polishing was then performed and the results are investigated. Outstanding surface roughness of Ra=3.8nm was obtained on the BK7 glass specimen. The present results highlight the possibility of applying this polishing method to ultra-precision micro parts production, especially in MEMS applications. PMID:27879705
ERIC Educational Resources Information Center
Chalasinski, Jozef
Diaries of rural youth writing during the transformation period of the Polish Peoples Republic (1950-1960's) were analyzed in terms of: individual autonomization and historical processes; identification with the Polish Peoples Republic and self-awareness (direct experience and historical awareness); youth and the revolutionary spirit of…
ERIC Educational Resources Information Center
Zubekhina, Tetiana
2015-01-01
This article provides a comparative analysis of the content of Bachelors' in Tourism informative training in Ukrainian and Polish experience. The content of Bachelors' in Tourism informative training in Ukraine and Poland has been analyzed. The content of subjects, namely, "Information Technologies in Tourism" and "The Foundations…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hubregsen, J.
1999-03-01
In the process of optical polishing, a new method has been developed called Magnetorheological Finishing, or MRF. This process utilizes both mechanical and chemical effects to remove material during polishing. To more fully understand the fundamental mechanisms of MR polishing the authors have successfully separated mechanical scratching from chemical softening in glass polishing with MRF by removing the water from the MR fluid. The addition of water initiates the chemical effects by hydrating the glass surface and changing the amplitude of the scratches. In addition, this study has found that the mechanical removal by scratching is related to the hardnessmore » of the magnetic carbonyl iron particles, and the hardness and type of the glass being polished.« less
Wagner, Monica; Shafer, Valerie L.; Martin, Brett; Steinschneider, Mitchell
2013-01-01
The effect of exposure to the contextual features of the /pt/ cluster was investigated in native-English and native-Polish listeners using behavioral and event-related potential (ERP) methodology. Both groups experience the /pt/ cluster in their languages, but only the Polish group experiences the cluster in the context of word onset examined in the current experiment. The /st/ cluster was used as an experimental control. ERPs were recorded while participants identified the number of syllables in the second word of nonsense word pairs. The results found that only Polish listeners accurately perceived the /pt/ cluster and perception was reflected within a late positive component of the ERP waveform. Furthermore, evidence of discrimination of /pt/ and /pǝt/ onsets in the neural signal was found even for non-native listeners who could not perceive the difference. These findings suggest that exposure to phoneme sequences in highly specific contexts may be necessary for accurate perception. PMID:22867752
Chen, Shaoshan; He, Deyu; Wu, Yi; Chen, Huangfei; Zhang, Zaijing; Chen, Yunlei
2016-10-01
A new non-aqueous and abrasive-free magnetorheological finishing (MRF) method is adopted for processing potassium dihydrogen phosphate (KDP) crystal due to its low hardness, high brittleness, temperature sensitivity, and water solubility. This paper researches the convergence rules of the surface error of an initial single-point diamond turning (SPDT)-finished KDP crystal after MRF polishing. Currently, the SPDT process contains spiral cutting and fly cutting. The main difference of these two processes lies in the morphology of intermediate-frequency turning marks on the surface, which affects the convergence rules. The turning marks after spiral cutting are a series of concentric circles, while the turning marks after fly cutting are a series of parallel big arcs. Polishing results indicate that MRF polishing can only improve the low-frequency errors (L>10 mm) of a spiral-cutting KDP crystal. MRF polishing can improve the full-range surface errors (L>0.01 mm) of a fly-cutting KDP crystal if the polishing process is not done more than two times for single surface. We can conclude a fly-cutting KDP crystal will meet better optical performance after MRF figuring than a spiral-cutting KDP crystal with similar initial surface performance.
ERIC Educational Resources Information Center
Pustulka, Paula; Slusarczyk, Magdalena
2016-01-01
The article elaborates on the recollections of schooling under the communist rule in Poland as presented in biographical interviews with contemporary Polish migrants living in the United Kingdom, Germany, and Norway. An analysis of childhood and schooling nexus is elicited on two platforms, specifically as (1) interviewees' first-hand experiences…
NASA Astrophysics Data System (ADS)
Suzuki, Hirofumi; Kawamori, Ryota; Yamamoto, Yuji; Miyabara, Mitsuru; Okino, Tadashi; Hijikata, Yoshio; Moriwaki, Toshimichi
2005-05-01
Micro aspherical glass lenses are required for electronic devices, optical devices and advanced optical fiber transmission equipments. The glass lenses are manufactured by glass molding method by using micro ceramics dies such as tungsten carbide or silicon carbide (1). Therefore molding dies are most important and they were ground by ultra-precision grinding method with diamond wheel. Recently, the wavelength of used laser is becoming shorter and then the accuracies of the micro molding die are required to be much more precise (2). In this paper, ultrasonic assisted polishing methods/systems were developed in order to finish micro aspherical dies that were ground with micro diamond wheel. In the polishing experiments, the molding die of tungsten carbide was polished with diamond abrasives to test the basic polishing characteristics and the aspheric die was polished with proposed ultrasonic assisted polishing method.
ERIC Educational Resources Information Center
Butler, Norman L.; Davidson, Barry S.; Pachocinski, Ryszard; Kritsonis, William Allan
2006-01-01
This article compares Polish post-secondary vocational (grammar) schools with Canadian community colleges. Recent changes in Polish schooling and Canadian government initiatives drive this work. Accessibility, governance and programs are discussed. The theoretical framework for this comparison was supplied by the notion of the school as an…
NASA Technical Reports Server (NTRS)
Wright, G.; Bryan, J. B.
1986-01-01
Faster production of large optical mirrors may result from combining single-point diamond crushing of the glass with polishing using a small area tool to smooth the surface and remove the damaged layer. Diamond crushing allows a surface contour accurate to 0.5 microns to be generated, and the small area computer-controlled polishing tool allows the surface roughness to be removed without destroying the initial contour. Final contours with an accuracy of 0.04 microns have been achieved.
Pressure distribution under flexible polishing tools. I - Conventional aspheric optics
NASA Astrophysics Data System (ADS)
Mehta, Pravin K.; Hufnagel, Robert E.
1990-10-01
The paper presents a mathematical model, based on Kirchoff's thin flat plate theory, developed to determine polishing pressure distribution for a flexible polishing tool. A two-layered tool in which bending and compressive stiffnesses are equal is developed, which is formulated as a plate on a linearly elastic foundation. An equivalent eigenvalue problem and solution for a free-free plate are created from the plate formulation. For aspheric, anamorphic optical surfaces, the tool misfit is derived; it is defined as the result of movement from the initial perfect fit on the optic to any other position. The Polisher Design (POD) software for circular tools on aspheric optics is introduced. NASTRAN-based finite element analysis results are compared with the POD software, showing high correlation. By employing existing free-free eigenvalues and eigenfunctions, the work may be extended to rectangular polishing tools as well.
Surface geometry of three packable and one hybrid composite after polishing.
Jung, Martin; Bruegger, Hilka; Klimek, Joachim
2003-01-01
This study evaluated the surface quality of four composite materials after polishing with six different polishing techniques. Eighty specimens were made using three packable composites (Definite/Degussa, SureFil/ Dentsply and Solitaire/Heraeus-Kulzer) and one hybrid composite (Herculite XRV/Kerr). Five specimens of each material were polished using flexible Sof-Lex discs. The remaining 75 specimens of each composite were prepared using three finishing protocols: a single 30 microm diamond (n = 25), two finishing diamonds (30/20 microm; n = 25) and a 30 microm diamond followed by a tungsten carbide finishing bur (n = 25). Final polishing of each of the three finishing groups was accomplished with SuperBuff, Diafix-oral, OneGloss, Astropol and HaWe Composite Polishers (n = 5, each). Surface roughness was evaluated quantitatively by laser-stylus profilometry. Average roughness (R(a)) was calculated; statistical analysis of the data was performed with two-way ANOVA and Scheffé post-hoc tests. The polished surfaces were examined qualitatively by SEM. The results showed significant effects on surface roughness from the different composites (p = 0.011) and polishing systems (p < 0.001). After polishing, the Solitaire surfaces (R(a) = 0.72 microm) were smoother than Definite (R(a) = 0.87 microm) and SureFil (R(a) = 0.89 microm) and significantly smoother than Herculite (R(a) = 0.92 microm; p = 0.011). Three of the polishing methods (SuperBuff, Diafix-oral and Astropol) achieved lower R(a)-values than Sof-Lex discs. The polishing quality of the one-step systems SuperBuff and Diafix-oral was strongly affected by the initial finishing protocol.
Sexual behavior and contraception among young Polish women.
Olszewski, Jaroslaw; Olszewska, Hanna; Abacjew-Chmylko, Anna; Chmylko, Lukasz; Gaworska-Krzeminska, Aleksandra; Wydra, Dariusz
2010-11-01
To analyze sexual behavior and the use of contraception among young women in Poland. Cross-sectional study. 1,478 young women in higher (78.9%) and secondary (21.1%) education. Gdansk region in Poland. The data were gathered between September and December 2008 by the use of a questionnaire prepared for the purpose of this study, completed anonymously and in person by the young women. Sexual activity had been initiated by 67.2% of the women studied at a mean age of 18.7 years (±1.97). Assessment was made of changes in their contraceptive practice between the time of sexual initiation and later sexual activity. Since their first experience of intercourse 67.0% did not change their contraceptive methods. As many as 40.1% continued using either low effective methods or no contraception. Early sexual initiation was linked to a significantly lower likelihood of highly effective contraception, more frequent unprotected sexual intercourse and more sexual partners (p < 0.05). Over half of women assigned to a 'high-risk' group with regard to the chance of unintended pregnancy and sexually transmitted infection, declared that their behavior did not carry any risk, similar (p > 0.05) to those who did not have a history of hazardous behavior. Sexual behavior differentiates Polish women from the women in Western Europe. Despite the welcome tendency toward choosing reliable contraceptives, use of appropriate contraception is still insufficient.
Uppal, Mudit; Ganesh, Arathi; Balagopal, Suresh; Kaur, Gurleen
2013-07-01
To evaluate the effect of three polishing protocols that could be implemented at recall on the surface roughness of two direct esthetic restorative materials. Specimens (n = 40) measuring 8 mm (length) × 5 mm (width) × 4 mm (height) were fabricated in an acrylic mold using two light-cured resin-based materials (microfilled composite and microhybrid composite). After photopolymerization, all specimens were finished and polished with one of three polishing protocols (Enhance, One Gloss, and Sof-Lex polishing systems). The average surface roughness of each treated specimen was determined using 3D optical profilometer. Next all specimens were brushed 60,000 times with nylon bristles at 7200 rpm using crosshead brushing device with equal parts of toothpaste and water used as abrasive medium. The surface roughness of each specimen was measured after brushing followed by repolishing with one of three polishing protocols, and then, the final surface roughness values were determined. The data were analyzed using one-way and two-factor analysis of variance (ANOVA) and Tukey's honestly significant difference (HSD). Significant difference (P < 0.05) in surface roughness was observed. Simulated brushing following initial polishing procedure significantly roughened the surface of restorative material (P < 0.05). Polishing protocols can be used to restore a smooth surface on esthetic restorative materials following simulated tooth brushing.
Rapid fabrication of a silicon modification layer on silicon carbide substrate.
Bai, Yang; Li, Longxiang; Xue, Donglin; Zhang, Xuejun
2016-08-01
We develop a kind of magnetorheological (MR) polishing fluid for the fabrication of a silicon modification layer on a silicon carbide substrate based on chemical theory and actual polishing requirements. The effect of abrasive concentration in MR polishing fluid on material removal rate and removal function shape is investigated. We conclude that material removal rate will increase and tends to peak value as the abrasive concentration increases to 0.3 vol. %, and the removal function profile will become steep, which is a disadvantage to surface frequency error removal at the same time. The removal function stability is also studied and the results show that the prepared MR polishing fluid can satisfy actual fabrication requirements. An aspheric reflective mirror of silicon carbide modified by silicon is well polished by combining magnetorheological finishing (MRF) using two types of MR polishing fluid and computer controlled optical surfacing (CCOS) processes. The surface accuracy root mean square (RMS) is improved from 0.087λ(λ=632.8 nm) initially to 0.020λ(λ=632.8 nm) in 5.5 h total and the tool marks resulting from MRF are negligible. The PSD analysis results also shows that the final surface is uniformly polished.
USSR and Eastern Europe Scientific Abstracts, Geophysics, Astronomy and Space, Number 426
1978-08-01
Report on "Soyuz-30" Docking.., 22 Comments on " Sirena " Experiment Aboard "Salyut-6" 24 Vereshchetin Comments on Polish Contribution to...began the joint Polish-Soviet materials processing experiment " Sirena " in the "Splav" apparatus. They were also engaged in physical exercise...34 Sirena " materials processing experiment was continued as the cosmonauts monitored the operation of the "Splav" apparatus and the temperature regime of
NASA Astrophysics Data System (ADS)
Shi, Feng; Shu, Yong; Dai, Yifan; Peng, Xiaoqiang; Li, Shengyi
2013-07-01
Based on the elastic-plastic deformation theory, status between abrasives and workpiece in magnetorheological finishing (MRF) process and the feasibility of elastic polishing are analyzed. The relationship among material removal mechanism and particle force, removal efficiency, and surface topography are revealed through a set of experiments. The chemical dominant elastic super-smooth polishing can be fulfilled by changing the components of magnetorheological (MR) fluid and optimizing polishing parameters. The MR elastic super-smooth finishing technology can be applied in polishing high-power laser-irradiated components with high efficiency, high accuracy, low damage, and high laser-induced damage threshold (LIDT). A 430×430×10 mm fused silica (FS) optic window is polished and surface error is improved from 538.241 nm [peak to valley (PV)], 96.376 nm (rms) to 76.372 nm (PV), 8.295 nm (rms) after 51.6 h rough polishing, 42.6 h fine polishing, and 54.6 h super-smooth polishing. A 50×50×10 mm sample is polished with exactly the same parameters. The roughness is improved from 1.793 nm [roughness average (Ra)] to 0.167 nm (Ra) and LIDT is improved from 9.77 to 19.2 J/cm2 after MRF elastic polishing.
Polish-made payload for the BRITE-PL 2 satellite Heweliusz
NASA Astrophysics Data System (ADS)
Zawistowski, Tomasz
2012-05-01
Two institutes of the Polish Academy of Sciences, Space Research Centre and Nicolaus Copernicus Astronomical Center cooperate on the project to build and place in orbit the first Polish scientific satellite. The BRITE (BRight Target Explorer) mission formed by Austria, Canada and Poland will send to space a constellation of six nanosatelites, two from each country. They will be observing star pulsations with fotometric methods gathering data that will verify thermodynamic models of bright, massive stars of our Galaxy, delivering information on their structure, formation and evolution. The first of two Polish satellites, "LEM", will closely resemble its international kin, while the second, "Heweliusz" will carry Polish flavor to space - delivering additional technological experiments. They will use commercial-off-the-shelf components.
Initial polishing time affects gloss retention in resin composites.
Waheeb, Nehal; Silikas, Nick; Watts, David
2012-10-01
To determine the effect of finishing and polishing time on the surface gloss of various resin-composites before and after simulated toothbrushing. Eight representative resin-composites (Ceram X mono, Ceram X duo, Tetric EvoCeram, Venus Diamond, EsteliteSigma Quick, Esthet.X HD, Filtek Supreme XT and Spectrum TPH) were used to prepare 80 disc-shaped (12 mm x 2 mm) specimens. The two step system Venus Supra was used for polishing the specimens for 3 minutes (Group A) and 10 minutes (Group B). All specimens were subjected to 16,000 cycles of simulated toothbrushing. The surface gloss was measured after polishing and after brushing using the gloss meter. Results were evaluated using one way ANOVA, two ways ANOVA and Dennett's post hoc test (P = 0.05). Group B (10-minute polishing) resulted in higher gloss values (GV) for all specimens compared to Group A (3 minutes). Also Group B showed better gloss retention compared to Group A after simulated toothbrushing. In each group, there was a significant difference between the polished composite resins (P < 0.05). For all specimens there was a decrease in gloss after the simulated toothbrushing.
Gloss and Stain Resistance of Ceramic-Polymer CAD/CAM Restorative Blocks.
Lawson, Nathaniel C; Burgess, John O
2016-03-01
To evaluate the gloss and stain resistance of several new ceramic-polymer CAD/CAM blocks Specimens (4 mm) were sectioned from: Enamic (polymer-infused ceramic), LAVA Ultimate (nano-ceramic reinforced polymer), e.max (lithium disilicate), Paradigm C (porcelain), and Paradigm MZ100 (composite). Specimens were wet polished on a polishing wheel to either 320 grit silicon paper (un-polished, N = 8) or 2000 grit silicon carbide papers followed by a 0.05 μm alumina slurry (polished, N = 8). Initial gloss and color (L*a*b*) values were measured. Specimens were stored in a staining solution at 37°C in darkness for 12 days (simulating 1 year). After storage, L*a*b* values re-measured. Change in color was reported as ΔE00 based on the CIEDE2000 formula. Gloss and ΔE00 were analyzed by two-way analysis of variance (ANOVA) (alpha = .05). Separate one-way ANOVA and Tukey post-hoc analyses were performed for both polish conditions and all materials. Two-way ANOVA showed that factors material, polish and their interaction were significant for both gloss and ΔE00 (p < .01). Post-hoc analysis reveals that polished specimens had significantly less color change than un-polished specimens for Paradigm C and LAVA Ultimate. E.max had significantly higher gloss and less color change than all other materials. The composition and polish of CAD/CAM materials affects gloss and stain resistance. Ceramic-polymer hybrid materials can achieve the high gloss required for esthetic restorations. These materials should be polished in order to minimize staining. If polished, all of the tested materials exhibited clinically acceptable color changes at 1 year of simulated staining. (J Esthet Restor Dent 28:S40-S45, 2016). © 2015 Wiley Periodicals, Inc.
Polishing of anaerobic secondary effluent by Chlorella vulgaris under low light intensity.
Cheng, Tuoyuan; Wei, Chun-Hai; Leiknes, TorOve
2017-10-01
To investigate anaerobic secondary effluent polishing by microalgae (Chlorella vulgaris) under low light intensity (14μmol/m 2 /s), bubbling column reactors were operated in batches of 8 d with initial ammonium nitrogen 10-50mg/L, initial phosphate phosphorus 2-10mg/L and microalgal seed 40mg/L. Maximum microalgal biomass and minimum generation time were 370.9mg/L and 2.5d, respectively. Nitrogen removal (maximum 99.6%) was mainly attributed to microalgal growth rate, while phosphorus removal (maximum 49.8%) was related to microalgal growth rate, cell phosphorus content (maximum 1.5%) and initial nutrients ratio. Dissolved microalgal organics release in terms of chemical oxygen demand (maximum 63.2mg/L) and hexane extractable material (i.e., oil and grease, maximum 8.5mg/L) was firstly reported and mainly affected by nitrogen deficiency and deteriorated effluent quality. Ultrafiltration critical flux (16.6-39.5L/m 2 /h) showed negative linear correlation to microalgal biomass. Anaerobic membrane bioreactor effluent polishing showed similar results with slight inhibition to synthetic effluent. Copyright © 2017 Elsevier Ltd. All rights reserved.
Dong, Zhichao; Cheng, Haobo; Tam, Hon-Yuen
2014-04-10
Numerical simulation of subaperture tool influence functions (TIF) is widely known as a critical procedure in computer-controlled optical surfacing. However, it may lack practicability in engineering because the emulation TIF (e-TIF) has some discrepancy with the practical TIF (p-TIF), and the removal rate could not be predicted by simulations. Prior to the polishing of a formal workpiece, opticians have to conduct TIF spot experiments on another sample to confirm the p-TIF with a quantitative removal rate, which is difficult and time-consuming for sequential polishing runs with different tools. This work is dedicated to applying these e-TIFs into practical engineering by making improvements from two aspects: (1) modifies the pressure distribution model of a flat-pitch polisher by finite element analysis and least square fitting methods to make the removal shape of e-TIFs closer to p-TIFs (less than 5% relative deviation validated by experiments); (2) predicts the removal rate of e-TIFs by reverse calculating the material removal volume of a pre-polishing run to the formal workpiece (relative deviations of peak and volume removal rate were validated to be less than 5%). This can omit TIF spot experiments for the particular flat-pitch tool employed and promote the direct usage of e-TIFs in the optimization of a dwell time map, which can largely save on cost and increase fabrication efficiency.
Effects of Polishing Bur Application Force and Reuse on Sintered Zirconia Surface Topography.
Fischer, N G; Tsujimoto, A; Baruth, A G
2018-03-16
Limited information is available on how to polish and finish zirconia surfaces following computer-aided design/computer-aided manufacturing (CAD/CAM), specifically, how differing application forces and reuse of zirconia polishing systems affect zirconia topography. To determine the effect of differing, clinically relevant, polishing application forces and multiple usages of polishing burs on the surface topography of CAD/CAM zirconia. One hundred twenty 220-grit carbide finished zirconia disks were sintered according to manufacturer's directions and divided into two groups for the study of two coarse polishing bur types. Each group was divided into subgroups for polishing (15,000 rpm) at 15 seconds for 1.0 N, 4.5 N, or 11 N of force using a purpose-built fixture. Subgroups were further divided to study the effects of polishing for the first, fifth, 15th, and 30th bur use, simulating clinical procedures. Unpolished surfaces served as a control group. Surfaces were imaged with noncontact optical profilometry (OP) and atomic force microscopy (AFM) to measure average roughness values (Ra). Polishing burs were optically examined for wear. Scanning electron microscopy (SEM) was performed on burs and zirconia surfaces. One-way ANOVA with post hoc Tukey HSD (honest significant difference) tests (α=0.05) were used for statistical analyses. AFM and OP Ra values of all polished surfaces were significantly lower than those of the unpolished control. Different polishing forces and bur reuse showed no significant differences in AFM Ra. However, significant differences in OP Ra were found due to differing application forces and bur reuse between the first and subsequent uses. SEM and optical micrographs revealed notable bur wear, increasing with increasing reuse. SEM and AFM micrographs clearly showed polished, periodic zirconia surfaces. Nanoscale topography, as analyzed with kurtosis and average groove depth, was found dependent on the specific polishing bur type. These in vitro results suggest changes in OP Ra due to bur reuse and polishing application force. Within the parameters of this study, the resultant topography of zirconia polishing is force-dependent and the reuse of coarse polishing burs is possible without statistically significant differences in Ra values after initial use. Nanoscale and microscale topography were shown to depend on specific polishing bur type.
Tsarev, V N; Ippolitov, E V; Trefilov, A G; Arutiunov, S D; Pivovarov, A A
2014-01-01
Study the main surface parameters of milled polyacrylic materials using atomic force microscopy and primary microbial adhesion of periodontopathogenic group bacteria and Candida albicans fungi taking into consideration the method of sample polishing. Studied samples: mill-treated without polishing (control); ergobox polished; polished in dental laboratory conditions; polished by a rubber brush in dentists' office. Microbial strains belonging to periodontopathogenic species (clinical isolates) that had been isolated from periodontal pockets of periodontitis patients: Porphyromonas gingivalis, Fusobacterium nucleatum, Streptococcus sanguis, C. albicans fungi were used for modelling experiments of primary adhesion of microbes to the material samples. S. sanguis had the highest degree of adhesion to polymer after milling, P. gingivalis, C. albicans--medium, F. nucleatum--low. A significant reduction of adhesion is observed during polishing in dental laboratory conditions or ergobox, less significant--during polishing in dental office. The data obtained allow to make a conclusion that the samples from polymer materials for preparation of prosthesis basis have varying degree of intensity of microbial adhesion of members of periodontopathogenic microflora and C. albicans fungi that depends on the polishing method, that accordingly determined the differences in colonization resistance against formation of microbial biofilm during polymer use in clinical conditions. . ,
Float polishing of optical materials.
Bennett, J M; Shaffer, J J; Shibano, Y; Namba, Y
1987-02-15
The float-polishing technique has been studied to determine its suitability for producing supersmooth surfaces on optical materials, yielding a roughness of <2 A rms. An attempt was made to polish six different materials including fused quartz, Zerodur, and sapphire. The low surface roughness was achieved on fused quartz, Zerodur, and Corning experimental glass-ceramic materials, and a surface roughness of <1 A rms was obtained on O-cut single-crystal sapphire. Presumably, similar surface finishes can also be obtained on CerVit and ULE quartz, which could not be polished satisfactorily in this set of experiments because of a mismatch between sample mounting and machine configuration.
[Józef Heller-one of organizers of Polish biochemistry in 1942-1973].
Zarebska, Zofia
2011-01-01
The article commemorates the activity of Józef Heller starting in 1921 with Jakub Parnas's group in Lvov which investigated the phosphorolysis of glycogen. The unknown events of His biography were disclosed, like military service in the Piłsudski's Legions at the rebirth of the Polish State and, subsequently, during the Nazi occupation of Poland--participation in the clandestine teaching of medical students. In the post-war times Józef Heller undertook teaching of medical students in Wrocław and next in Warsaw. In 1954 He begun to organize the Institute of Biochemistry and Biophysics of the Polish Academy of Sciences--it now continues its activity. Professor Heller initiated the publication in Poland of three major biochemical journals, including Postepy Biochemii (1954). Thanks to His leadership the first Polish Medical Dictionary was published (1981). The article summarizes the pursuit of Józef Heller in various branches of academic life, which were and still are appreciated by subsequent generations of Polish biochemists.
Professional Training of Economists at Polish Universities
ERIC Educational Resources Information Center
Ogienko, Olena
2016-01-01
Polish experience in professional training of economists at university has been generalized. Structural, content and procedural peculiarities of the training have been defined. It has been proved that key factors for reforming economic education in Poland are globalization, internationalization, integration, technologization and informatization.…
Removal of single point diamond-turning marks by abrasive jet polishing.
Li, Z Z; Wang, J M; Peng, X Q; Ho, L T; Yin, Z Q; Li, S Y; Cheung, C F
2011-06-01
Single point diamond turning (SPDT) is highly controllable and versatile in producing axially symmetric forms, non-axially-symmetric forms, microstructured surfaces, and free forms. However, the fine SPDT marks left in the surface limit its performance, and they are difficult to reduce or eliminate. It is unpractical for traditional methods to remove the fine marks without destroying their forms, especially for the aspheres and free forms. This paper introduces abrasive jet polishing (AJP) for the posttreatment of diamond-turned surfaces to remove the periodic microstructures. Samples of diamond-turned electroless nickel plated plano mirror were used in the experiments. One sample with an original surface roughness of more than 400 nm decreased to 4 nm after two iterations abrasive jet polishing; the surface roughness of another sample went from 3.7 nm to 1.4 nm after polishing. The periodic signatures on both of the samples were removed entirely after polishing. Contrastive experimental research was carried out on electroless nickel mirror with magnetorheological finishing, computer controlled optical surfacing, and AJP. The experimental results indicate that AJP is more appropriate in removing the periodic SPDT marks. Also, a figure maintaining experiment was carried out with the AJP process; the uniform polishing process shows that the AJP process can remove the periodic turning marks without destroying the original form.
Composite adaptive control of belt polishing force for aero-engine blade
NASA Astrophysics Data System (ADS)
Zhsao, Pengbing; Shi, Yaoyao
2013-09-01
The existing methods for blade polishing mainly focus on robot polishing and manual grinding. Due to the difficulty in high-precision control of the polishing force, the blade surface precision is very low in robot polishing, in particular, quality of the inlet and exhaust edges can not satisfy the processing requirements. Manual grinding has low efficiency, high labor intensity and unstable processing quality, moreover, the polished surface is vulnerable to burn, and the surface precision and integrity are difficult to ensure. In order to further improve the profile accuracy and surface quality, a pneumatic flexible polishing force-exerting mechanism is designed and a dual-mode switching composite adaptive control(DSCAC) strategy is proposed, which combines Bang-Bang control and model reference adaptive control based on fuzzy neural network(MRACFNN) together. By the mode decision-making mechanism, Bang-Bang control is used to track the control command signal quickly when the actual polishing force is far away from the target value, and MRACFNN is utilized in smaller error ranges to improve the system robustness and control precision. Based on the mathematical model of the force-exerting mechanism, simulation analysis is implemented on DSCAC. Simulation results show that the output polishing force can better track the given signal. Finally, the blade polishing experiments are carried out on the designed polishing equipment. Experimental results show that DSCAC can effectively mitigate the influence of gas compressibility, valve dead-time effect, valve nonlinear flow, cylinder friction, measurement noise and other interference on the control precision of polishing force, which has high control precision, strong robustness, strong anti-interference ability and other advantages compared with MRACFNN. The proposed research achieves high-precision control of the polishing force, effectively improves the blade machining precision and surface consistency, and significantly reduces the surface roughness.
Al-Haj Husain, Nadin; Camilleri, Josette; Özcan, Mutlu
2016-12-01
Polishing procedures might alter monolithic zirconia (MZ) surface resulting in phase changes that can be deleterious for clinical performance and antagonist tooth wear. This study investigated the topographical features and phase transformation in MZ after polishing with different regimens simulating the clinical workflow. MZ specimens (Katana Zirconia HT, Kuraray-Noritake) (12×12×1.8 mm(3)) were grinded and polished using one of the five systems assessed: BG: Silicone carbide polishers (Brownie, Greenie, Super Greenie); CG: Diamond impregnated ceramic polisher kit (Ceragloss); EV: Synthetically bonded grinder interspersed with diamond (EVE Kit); SL: Urethane coated paper with aluminium oxide grits (Soflex Finishing and Polishing System Kit) and DB: Diamond bur (8 µm). Polished specimens were initially roughened with 220 µm diamond burs (Grinding Bur-GB) (10 s, 160.000160,000 rpm) and considered for baseline measurements. Polishing regimens were performed for 10 s using a slow-speed hand piece under water-cooling except for SL, in a custom made device (750 g; 5000 and 75,000 rpm). Surface roughnesses, phase changes (XRD) were assessed, surface characterization was performed (SEM, EDS). The highest roughness was obtained with the EV system (1.11 µm) compared to those of other systems (0.13-0.4 µm) (pθ and minor peak at 34.94°2θ. While GB, CG, EV, SL and DB exhibited a peak shift to the left, BG demonstrated a right peak shift on the 2θ scale. Monoclinic phase change was not noted in any of the groups. All polishing methods, except BG, exhibited a peak shift towards the lower angles of the 2-theta scale. Since the peak shifts were in the order of fractions of an angle they are attributed to stress formation rather than a phase change in the material. Thus, all polishing systems tested may not be detrimental for the phase transformation of MZ. EV system resulted in the highest roughness and none of the polishing regimens restored the polishability to the baseline level. Copyright © 2016 Elsevier Ltd. All rights reserved.
Removing function model and experiments on ultrasonic polishing molding die
NASA Astrophysics Data System (ADS)
Huang, Qitai; Ni, Ying; Yu, Jingchi
2010-10-01
Low temperature glass molding technology is the main method on volume-producing high precision middle and small diameter optical cells in the future. While the accuracy of the molding die will effect the cell precision, so the high precision molding die development is one of the most important part of the low temperature glass molding technology. The molding die is manufactured from high rigid and crisp metal alloy, with the ultrasonic vibration character of high vibration frequency and concentrative energy distribution; abrasive particles will impact the rigid metal alloy surface with very high speed that will remove the material from the work piece. Ultrasonic can make the rigid metal alloy molding die controllable polishing and reduce the roughness and surface error. Different from other ultrasonic fabrication method, untouched ultrasonic polishing is applied on polish the molding die, that means the tool does not touch the work piece in the process of polishing. The abrasive particles vibrate around the balance position with high speed and frequency under the drive of ultrasonic vibration in the liquid medium and impact the workspace surface, the energy of abrasive particles come from ultrasonic vibration, while not from the direct hammer blow of the tool. So a nummular vibrator simple harmonic vibrates on an infinity plane surface is considered as a model of ultrasonic polishing working condition. According to Huygens theory the sound field distribution on a plane surface is analyzed and calculated, the tool removing function is also deduced from this distribution. Then the simple point ultrasonic polishing experiment is proceeded to certificate the theory validity.
Impact of initial surface parameters on the final quality of laser micro-polished surfaces
NASA Astrophysics Data System (ADS)
Chow, Michael; Bordatchev, Evgueni V.; Knopf, George K.
2012-03-01
Laser micro-polishing (LμP) is a new laser-based microfabrication technology for improving surface quality during a finishing operation and for producing parts and surfaces with near-optical surface quality. The LμP process uses low power laser energy to melt a thin layer of material on the previously machined surface. The polishing effect is achieved as the molten material in the laser-material interaction zone flows from the elevated regions to the local minimum due to surface tension. This flow of molten material then forms a thin ultra-smooth layer on the top surface. The LμP is a complex thermo-dynamic process where the melting, flow and redistribution of molten material is significantly influenced by a variety of process parameters related to the laser, the travel motions and the material. The goal of this study is to analyze the impact of initial surface parameters on the final surface quality. Ball-end micromilling was used for preparing initial surface of samples from H13 tool steel that were polished using a Q-switched Nd:YAG laser. The height and width of micromilled scallops (waviness) were identified as dominant parameter affecting the quality of the LμPed surface. By adjusting process parameters, the Ra value of a surface, having a waviness period of 33 μm and a peak-to-valley value of 5.9 μm, was reduced from 499 nm to 301 nm, improving the final surface quality by 39.7%.
Diagnostics and Treatment of Thyroid Carcinoma.
Jarząb, Barbara; Dedecjus, Marek; Handkiewicz-Junak, Daria; Lange, Dariusz; Lewiński, Andrzej; Nasierowska-Guttmejer, Anna; Ruchała, Marek; Słowińska-Klencka, Dorota; Nauman, Janusz; Adamczewski, Zbigniew; Bagłaj, Maciej; Bałdys-Waligórska, Agata; Barczyński, Marcin; Bednarczuk, Tomasz; Cichocki, Andrzej; Czarniecka, Agnieszka; Czepczyński, Rafał; Gawlik, Aneta; Hubalewska-Dydejczyk, Alicja; Jażdżewski, Krystian; Kamiński, Grzegorz; Karbownik-Lewińska, Małgorzata; Kos-Kudła, Beata; Kułakowski, Andrzej; Kuzdak, Krzysztof; Łącka, Katarzyna; Małecka-Tendera, Ewa; Niedziela, Marek; Pomorski, Lech; Sporny, Stanisław; Stojcev, Zoran; Syrenicz, Anhelli; Włoch, Jan; Krajewska, Jolanta; Szpak-Ulczok, Sylwia; Kalemba, Michal; Buziak-Bereza, Monika
2016-01-01
Revised Guidelines of Polish National Societies Prepared on the initiative of the Polish Group for Endocrine Tumours approved in their final version between November 16th and 28th, 2015 by the Scientific Committee of the V Conference "Thyroid Cancer and other malignancies of endocrine glands" organised between November 14th and 17th, 2015 in Wisla, Poland; called by the following Societies: Polish Endocrine Society, Polish Society of Oncology, Polish Thyroid Association, Polish Society of Pathologists, Society of Polish Surgeons, Polish Society of Surgical Oncology, Polish Society of Clinical Oncology, Polish Society of Radiation Oncology, Polish Society of Nuclear Medicine, Polish Society of Paediatric Endocrinology, Polish Society of Paediatric Surgeons, Polish Society of Ultrasonography Gliwice-Wisła, 2015 DECLARATION: These recommendations are created by the group of delegates of the National Societies, which declare their willingness to participate in the preparation of the revised version of the Polish Guidelines. The members of the Working Group have been chosen from the specialists involved in medical care of patients with thyroid carcinoma. Directly before the preparation of the Polish national recommendations the American Thyroid Association (ATA) published its own guidelines together with a wide comment fulfilling evidence-based medicine (EBM) criteria. ATA Guidelines are consistent with National Comprehensive Cancer Network (NCCN) Recommendation. According to the members of the Working Group, it is necessary to adapt them to both the specific Polish epidemiological situation as well as to the rules referring to the Polish health system. Therefore, the Polish recommendations constitute a consensus of the experts' group, based on ATA information. The experts analysed previous Polish Guidelines, published in 2010, and other available data, and after discussion summed up the results in the form of these guidelines. It should be added that Part II, which constitutes a pathological part, has been available at the website of the Polish Society of Pathologists for acceptance of the members of the Society, and no essential comments have been proposed. The Members of the Group decided that a subgroup elected from among them would update the Guidelines, according to EBM rules, every year. The Revised Guidelines should help physicians to make reasonable choices in their daily practice; however, the final decision concerning an individual patient should be made by the caring physician responsible for treatment, or optimally by a therapeutic tumour board together with the patient, and should take into consideration the patient's health condition. It should be emphasised that the recommendations may not constitute a strict standard of clinical management imposed on medical staff. The data from clinical trials concerning numerous clinical situations are scarce. In such moments the opinion of the management may differ from the recommendations after considering possible benefits and disadvantages for the patient.
Single nucleotide polymorphism discovery in bovine liver using RNA-seq technology.
Pareek, Chandra Shekhar; Błaszczyk, Paweł; Dziuba, Piotr; Czarnik, Urszula; Fraser, Leyland; Sobiech, Przemysław; Pierzchała, Mariusz; Feng, Yaping; Kadarmideen, Haja N; Kumar, Dibyendu
2017-01-01
RNA-seq is a useful next-generation sequencing (NGS) technology that has been widely used to understand mammalian transcriptome architecture and function. In this study, a breed-specific RNA-seq experiment was utilized to detect putative single nucleotide polymorphisms (SNPs) in liver tissue of young bulls of the Polish Red, Polish Holstein-Friesian (HF) and Hereford breeds, and to understand the genomic variation in the three cattle breeds that may reflect differences in production traits. The RNA-seq experiment on bovine liver produced 107,114,4072 raw paired-end reads, with an average of approximately 60 million paired-end reads per library. Breed-wise, a total of 345.06, 290.04 and 436.03 million paired-end reads were obtained from the Polish Red, Polish HF, and Hereford breeds, respectively. Burrows-Wheeler Aligner (BWA) read alignments showed that 81.35%, 82.81% and 84.21% of the mapped sequencing reads were properly paired to the Polish Red, Polish HF, and Hereford breeds, respectively. This study identified 5,641,401 SNPs and insertion and deletion (indel) positions expressed in the bovine liver with an average of 313,411 SNPs and indel per young bull. Following the removal of the indel mutations, a total of 195,3804, 152,7120 and 205,3184 raw SNPs expressed in bovine liver were identified for the Polish Red, Polish HF, and Hereford breeds, respectively. Breed-wise, three highly reliable breed-specific SNP-databases (SNP-dbs) with 31,562, 24,945 and 28,194 SNP records were constructed for the Polish Red, Polish HF, and Hereford breeds, respectively. Using a combination of stringent parameters of a minimum depth of ≥10 mapping reads that support the polymorphic nucleotide base and 100% SNP ratio, 4,368, 3,780 and 3,800 SNP records were detected in the Polish Red, Polish HF, and Hereford breeds, respectively. The SNP detections using RNA-seq data were successfully validated by kompetitive allele-specific PCR (KASPTM) SNP genotyping assay. The comprehensive QTL/CG analysis of 110 QTL/CG with RNA-seq data identified 20 monomorphic SNP hit loci (CARTPT, GAD1, GDF5, GHRH, GHRL, GRB10, IGFBPL1, IGFL1, LEP, LHX4, MC4R, MSTN, NKAIN1, PLAG1, POU1F1, SDR16C5, SH2B2, TOX, UCP3 and WNT10B) in all three cattle breeds. However, six SNP loci (CCSER1, GHR, KCNIP4, MTSS1, EGFR and NSMCE2) were identified as highly polymorphic among the cattle breeds. This study identified breed-specific SNPs with greater SNP ratio and excellent mapping coverage, as well as monomorphic and highly polymorphic putative SNP loci within QTL/CGs of bovine liver tissue. A breed-specific SNP-db constructed for bovine liver yielded nearly six million SNPs. In addition, a KASPTM SNP genotyping assay, as a reliable cost-effective method, successfully validated the breed-specific putative SNPs originating from the RNA-seq experiments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palczewski, Ari D.; Tian, Hui; Trofimova, Olga
2011-07-01
We performed Centrifugal Barrel Polishing (CBP) on single crystal niobium samples/coupons housed in a stainless steel sample holder following the polishing recipe developed at Fermi Lab (FNAL) in 2011 \\cite{C. A. Cooper 2011}. Post CBP, the sample coupons were analyzed for surface roughness, crystal composition and structure, and particle contamination. Following the initial analysis each coupon was high pressure rinsed (HRP) and analyzed for the effectiveness of contamination removal. We were able to obtain the mirror like surface finish after the final stage of tumbling, although some defects and embedded particles remained. In addition, standard HPR appears to have littlemore » effect on removing embedded particles which remain after each tumbling step, although final polishing media removal was partially affected by standard/extended HPR.« less
Adaptation of the ORTHO-15 test to Polish women and men.
Brytek-Matera, Anna; Krupa, Magdalena; Poggiogalle, Eleonora; Donini, Lorenzo Maria
2014-03-01
There is a lack of Polish tools to measure behaviour related to orthorexia nervosa. The purpose of the present study was to validate the Polish version of the ORTHO-15 test. 341 women and 59 men (N = 400) were recruited, whose age ranged from 18 to 35 years. Mean age was 23.09 years (SD = 3.14) in women and 24.02 years (SD = 3.87) in men. The ORTHO-15 test and the EAT-26 test were used in the present study. Factor analysis (exploratory and confirmatory analysis) was used in the present study. Exploratory factor analysis performed on the initial 15 items from a random split half of the study group suggested a nine-item two-factor structure. Confirmatory factor analysis performed on the second randomly selected half of the study group supported this two-factor structure of the ORTHO-15 test. The Polish version of the ORTHO-15 test demonstrated an internal consistency (Cronbach's alpha) equal to 0.644. The Polish version of the ORTHO-15 test is a reliable and valuable instrument to assess obsessive attitudes related to healthy and proper nutrition in Polish female and male population.
Cwiklińska, Agnieszka; Kąkol, Judyta; Kuchta, Agnieszka; Kortas-Stempak, Barbara; Pacanis, Anastasis; Rogulski, Jerzy; Wróblewska, Małgorzata
2012-02-01
Given the common problems with the standardization of urine particle counting methods and the great variability in the results obtained by Polish laboratories under international Labquality External Quality Assessment (EQA), we initiated educational recovery activities. Detailed instructions on how to perform the standardized examination were sent to EQA participants, as was a questionnaire forms which enabled information to be gathered in respect to the procedures being applied. Laboratory results were grouped according to the method declared on the EQA 'Result' form or according to a manual examination procedure established on the basis of the questionnaire. The between-laboratory CVs for leukocyte and erythrocyte counts were calculated for each group and compared using the Mann-Whitney test. Significantly lower between-laboratory CVs (p = 0.03) were achieved for leukocyte counting among the laboratories that analysed control specimens in accordance with standardized procedures as compared with those which used non-standardized procedures. We also observed a visible lower variability for erythrocyte counting. Unfortunately despite our activities, only a few of the Polish laboratories applied the standardized examination procedures, and only 29% of the results could have been considered to be standardized (16% - manual methods, 13% - automated systems). The standardization of urine particle counting methods continues to be a significant problem in medical laboratories and requires further recovery activities which can be conducted using the EQA scheme.
[Contribution of the Polish-German Mental Health Society to changes in Polish psychiatry].
Cichocki, Łukasz; Cechnicki, Andrzej
2014-01-01
The aim of this presentation is to give a profile of the history and work of the Polish-German Mental Health Society (PNTZP). Founded in 1990, the PNTZP's supreme objective is to develop and reinforce partnership between Polish and German psychiatry on a range of levels. The methods it uses to further this aim include bilateral meetings, seminars, and annual symposia. In view of its historical roots, the PNTZP is constantly mindful of the excesses perpetrated on the mentally ill during the National Socialist period, and believes it has an obligation to promote a brand of psychiatry founded on the person, respect for human dignity, and the will and individuality of every man. For this reason, ethics are an essential element of discussion, including discussions with patients and their families. The society advocates the implementation of the National Programme of Mental Health Care and the development of community psychiatry in Poland. It supports the development of various structures for the treatment and assistance of people with mental illness, as well as scientific and academic reflection on the social and cultural implications of psychiatric thought and action. It is committed to facilitating the exchange of experiences between different professional groups, patients, and their families in order to promote mutual inspiration and support in the challenging task of developing psychiatry. A record of these years of meetings may be found in the twenty issues of the periodical Dialog. This example of cooperation across official state borders may be held up as a benchmark for the development of European psychiatry, and the joint work and discussions may offer help and inspiration in day-to-day therapeutic practice. The PNTZP is open to new people and initiatives, and is always looking for people willing to get involved in its work.
Zirconia coated carbonyl iron particle-based magnetorheological fluid for polishing
NASA Astrophysics Data System (ADS)
Shafrir, Shai N.; Romanofsky, Henry J.; Skarlinski, Michael; Wang, Mimi; Miao, Chunlin; Salzman, Sivan; Chartier, Taylor; Mici, Joni; Lambropoulos, John C.; Shen, Rui; Yang, Hong; Jacobs, Stephen D.
2009-08-01
Aqueous magnetorheological (MR) polishing fluids used in magnetorheological finishing (MRF) have a high solids concentration consisting of magnetic carbonyl iron particles and nonmagnetic polishing abrasives. The properties of MR polishing fluids are affected over time by corrosion of CI particles. Here we report on MRF spotting experiments performed on optical glasses using a zirconia coated carbonyl iron (CI) particle-based MR fluid. The zirconia coated magnetic CI particles were prepared via sol-gel synthesis in kg quantities. The coating layer was ~50-100 nm thick, faceted in surface structure, and well adhered. Coated particles showed long term stability against aqueous corrosion. "Free" nano-crystalline zirconia polishing abrasives were co-generated in the coating process, resulting in an abrasivecharged powder for MRF. A viable MR fluid was prepared simply by adding water. Spot polishing tests were performed on a variety of optical glasses over a period of 3 weeks with no signs of MR fluid degradation or corrosion. Stable material removal rates and smooth surfaces inside spots were obtained.
Computer-Controlled Cylindrical Polishing Process for Large X-Ray Mirror Mandrels
NASA Technical Reports Server (NTRS)
Khan, Gufran S.; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian
2010-01-01
We are developing high-energy grazing incidence shell optics for hard-x-ray telescopes. The resolution of a mirror shells depends on the quality of cylindrical mandrel from which they are being replicated. Mid-spatial-frequency axial figure error is a dominant contributor in the error budget of the mandrel. This paper presents our efforts to develop a deterministic cylindrical polishing process in order to keep the mid-spatial-frequency axial figure errors to a minimum. Simulation software is developed to model the residual surface figure errors of a mandrel due to the polishing process parameters and the tools used, as well as to compute the optical performance of the optics. The study carried out using the developed software was focused on establishing a relationship between the polishing process parameters and the mid-spatial-frequency error generation. The process parameters modeled are the speeds of the lap and the mandrel, the tool s influence function, the contour path (dwell) of the tools, their shape and the distribution of the tools on the polishing lap. Using the inputs from the mathematical model, a mandrel having conical approximated Wolter-1 geometry, has been polished on a newly developed computer-controlled cylindrical polishing machine. The preliminary results of a series of polishing experiments demonstrate a qualitative agreement with the developed model. We report our first experimental results and discuss plans for further improvements in the polishing process. The ability to simulate the polishing process is critical to optimize the polishing process, improve the mandrel quality and significantly reduce the cost of mandrel production
Computer numeric control subaperture aspheric surface polishing-microroughness evaluation
NASA Astrophysics Data System (ADS)
Prochaska, Frantisek; Polak, Jaroslav; Matousek, Ondrej; Tomka, David
2014-09-01
The aim of this work was an investigation of surface microroughness and shape accuracy achieved on an aspheric lens by subaperture computer numeric control (CNC) polishing. Different optical substrates were polished (OHARA S-LAH 58, SF4, ZERODUR) using a POLITEX™ polishing pad, synthetic pitch, and the natural optical pitch. Surface roughness was measured by light interferometer. The best results were achieved on the S-LAH58 glass and the ZERODUR™ using the natural optical pitch. In the case of SF4 glass, the natural optical pitch showed a tendency to scratch the surface. Experiments also indicated a problem in surface form deterioration when using the natural optical pitch, regardless of the type of optical material.
Effect of sulfur removal on Al2O3 scale adhesion
NASA Astrophysics Data System (ADS)
Smialek, James L.
1991-03-01
If the role of reactive element dopants in producing A12O3 scale adhesion on NiCrAl alloys is to getter sulfur and prevent interfacial segregation, then eliminating sulfur from undoped alloys should also produce adherence. Four experiments successfully produced scale adhesion by sulfur removal alone. (1) Repeated oxidation and polishing of a pure NiCrAl alloy lowered the sulfur content from 10 to 2 parts per million by weight (ppmw), presumably by removing the segregated interfacial layer after each cycle. Total scale spallation changed to total retention after 13 such cycles, with no changes in the scale or interfacial morphology. (2) Thinner samples became adherent after fewer oxidation polishing cycles because of a more limited supply of sulfur. (3) Spalling in subsequent cyclic oxidation tests of samples from experiment (1) was a direct function of the initial sulfur content. (4) Desulfurization to 0.1 ppmw levels was accomplished by annealing melt-spun foil in 1 arm H2. These foils produced oxidation weight change curves for 500 1-hour cycles at 1100 °C similar to those for Y- or Zr-doped NiCrAl. The transition between adherent and nonadherent behavior was modeled in terms of sulfur flux, sulfur content, and sulfur segregation.
Initial Subdivision of Genesis Early Science Polished Aluminum Collector
NASA Technical Reports Server (NTRS)
Allton, J. H.; Stansbery, E. K.; McNamara, K. M.; Meshik, A.; See, T. H.; Bastien, R.
2005-01-01
A large surface, about 245 square centimeters, of highly polished aluminum 6061 T6 alloy was attached to the science canister thermal panel for the purpose of collecting solar wind noble gases. The analysis of this collector will be part of the Genesis Early Science results. The pre-launch configuration of the collector is shown. The collector sustained some damage during the recovery impact in Utah, September 8, 2004.
Development of TIF based figuring algorithm for deterministic pitch tool polishing
NASA Astrophysics Data System (ADS)
Yi, Hyun-Su; Kim, Sug-Whan; Yang, Ho-Soon; Lee, Yun-Woo
2007-12-01
Pitch is perhaps the oldest material used for optical polishing, leaving superior surface texture, and has been used widely in the optics shop floor. However, for its unpredictable controllability of removal characteristics, the pitch tool polishing has been rarely analysed quantitatively and many optics shops rely heavily on optician's "feel" even today. In order to bring a degree of process controllability to the pitch tool polishing, we added motorized tool motions to the conventional Draper type polishing machine and modelled the tool path in the absolute machine coordinate. We then produced a number of Tool Influence Function (TIF) both from an analytical model and a series of experimental polishing runs using the pitch tool. The theoretical TIFs agreed well with the experimental TIFs to the profile accuracy of 79 % in terms of its shape. The surface figuring algorithm was then developed in-house utilizing both theoretical and experimental TIFs. We are currently undertaking a series of trial figuring experiments to prove the performance of the polishing algorithm, and the early results indicate that the highly deterministic material removal control with the pitch tool can be achieved to a certain level of form error. The machine renovation, TIF theory and experimental confirmation, figuring simulation results are reported together with implications to deterministic polishing.
Rahal, Juliana Saab; Mesquita, Marcelo Ferraz; Henriques, Guilherme Elias Pessanha; Nóbilo, Mauro Antonio Arruda
2004-01-01
Influence of polishing methods on water sorption and solubility of denture base acrylic resins was studied. Eighty samples were divided into groups: Classico (CL), and QC 20 (QC) - hot water bath cured; Acron MC (AC), and Onda Cryl (ON) - microwave cured; and submitted to mechanical polishing (MP) - pumice slurry, chalk powder, soft brush and felt cone in a bench vise; or chemical polishing (CP) - heated monomer fluid in a chemical polisher. The first desiccation process was followed by storage in distilled water at 37 +/- 1 degrees C for 1 h, 1 day, 1, 2, 3 and 4 weeks. Concluding each period, water sorption was measured. After the fourth week, a second desiccation process was done to calculate solubility. Data were submitted to analysis of variance, followed by Tukey test (p
NASA Astrophysics Data System (ADS)
Rodolfo, J.; Ruch, E.; Tarreau, M.; Merceron, J.-M.; Ferré, J.; Rousselet, N.; Leplan, H.; Geyl, R.; Harnisch, B.
2017-11-01
Silicon Carbide is a material of high interest in the design and manufacturing of space telescopes, thanks to its mechanical and thermal properties. Since many years, Reosc has gathered a large experience in the polishing, testing, integration and coating of large size Silicon Carbide mirrors as well as in the integration of full SiC TMAs.
NASA Astrophysics Data System (ADS)
Peng, Wenqiang; Guan, Chaoliang; Li, Shengyi; Wang, Zhuo
2016-10-01
Surface and subsurface damage in optical element will greatly decrease the laser induced damage threshold (LIDT) in the intense laser optical system. Processing damage on the workpiece surface can be inevitably caused when the material is removed in brittle or plastic mode. As a non-contact polishing technology, hydrodynamic effect polishing (HEP) shows very good performance on generating an ultra-smooth surface without damage. The material is removed by chemisorption between nanoparticle and workpiece surface in the elastic mode in HEP. The subsurface damage and surface scratches can be effectively removed after the polishing process. Meanwhile ultra-smooth surface with atomic level surface roughness can be achieved. To investigate the improvement of LIDT of optical workpiece, polishing experiment was conducted on a magnetorheological finishing (MRF) silica glass sample. AFM measurement results show that all the MRF directional plastic marks have been removed clearly and the root-mean-square (rms) surface roughness has decreased from 0.673nm to 0.177nm after HEP process. Laser induced damage experiment was conducted with laser pulse of 1064nm wavelength and 10ns time width. Compared with the original state, the LEDT of the silica glass sample polished by HEP has increased from 29.78J/cm2 to 45.47J/cm2. It demonstrates that LIDT of optical element treated by HEP can be greatly improved for ultra low surface roughness and nearly defect-free surface/subsurface.
NASA Astrophysics Data System (ADS)
Gora, Wojciech S.; Tian, Yingtao; Cabo, Aldara Pan; Ardron, Marcus; Maier, Robert R. J.; Prangnell, Philip; Weston, Nicholas J.; Hand, Duncan P.
Additive manufacturing (AM) offers the possibility of creating a complex free form object as a single element, which is not possible using traditional mechanical machining. Unfortunately the typically rough surface finish of additively manufactured parts is unsuitable for many applications. As a result AM parts must be post-processed; typically mechanically machined and/or and polished using either chemical or mechanical techniques (both of which have their limitations). Laser based polishing is based on remelting of a very thin surface layer and it offers potential as a highly repeatable, higher speed process capable of selective area polishing, and without any waste problems (no abrasives or liquids). In this paper an in-depth investigation of CW laser polishing of titanium and cobalt chrome AM elements is presented. The impact of different scanning strategies, laser parameters and initial surface condition on the achieved surface finish is evaluated.
Research on high-efficiency polishing technology of photomask substrate
NASA Astrophysics Data System (ADS)
Zhao, Shijie; Xie, Ruiqing; Zhou, Lian; Liao, Defeng; Chen, Xianhua; Wang, Jian
2018-03-01
A method of photomask substrate fabrication is demonstrated ,that the surface figure and roughness of fused silica will converge to target precision rapidly with the full aperture polishing. Surface figure of optical flats in full aperture polishing processes is primarily dependent on the surface profile of polishing pad, therefor, a improved function of polishing mechanism was put forward based on two axis lapping machine and technology experience, and the pad testing based on displacement sensor and the active conditioning method of the pad is applied in this research. Moreover , the clamping deformation of the thin glass is solved by the new pitch dispensing method. The experimental results show that the surface figure of the 152mm×152mm×6.35mm optical glass is 0.25λ(λ=633nm) and the roughness is 0.32nm ,which has meet the requirements of mask substrate for 90 45nm nodes.
Electrochemical and mechanical polishing and shaping method and system
NASA Technical Reports Server (NTRS)
Engelhaupt, Darell E. (Inventor); Gubarev, Mikhail V. (Inventor); Jones, William David (Inventor); Ramsey, Brian D. (Inventor); Benson, Carl M. (Inventor)
2011-01-01
A method and system are provided for the shaping and polishing of the surface of a material selected from the group consisting of electrically semi-conductive materials and conductive materials. An electrically non-conductive polishing lap incorporates a conductive electrode such that, when the polishing lap is placed on the material's surface, the electrode is placed in spaced-apart juxtaposition with respect to the material's surface. A liquid electrolyte is disposed between the material's surface and the electrode. The electrolyte has an electrochemical stability constant such that cathodic material deposition on the electrode is not supported when a current flows through the electrode, the electrolyte and the material. As the polishing lap and the material surface experience relative movement, current flows through the electrode based on (i) adherence to Faraday's Law, and (ii) a pre-processing profile of the surface and a desired post-processing profile of the surface.
Forces acting between polishing tool and workpiece surface in magnetorheological finishing
NASA Astrophysics Data System (ADS)
Schinhaerl, Markus; Vogt, Christian; Geiss, Andreas; Stamp, Richard; Sperber, Peter; Smith, Lyndon; Smith, Gordon; Rascher, Rolf
2008-08-01
Magnetorheological finishing is a computer-controlled polishing technique that is used mainly in the field of high-quality optical lens production. The process is based on the use of a magnetorheological polishing fluid that is able, in a reversible manner, to change its viscosity from a liquid state to a solid state under the control of a magnetic field. This outstanding characteristic facilitates rapid control (in milliseconds) of the yield stress, and thus the pressure applied to the workpiece surface to be polished. A three-axis dynamometer was used to measure the forces acting between the magnetorheological fluid and the workpiece surface during determination of the material removal characteristic of the polishing tool (influence function). The results of a testing series using a QED Q22-X MRF polishing machine with a 50 mm wheel assembly show that the normal forces range from about 2 to 20 N. Knowledge of the forces is essential, especially when thin workpieces are to be polished and distortion becomes significant. This paper discusses, and gives examples of, the variation in the parameters experienced during a programme of experiments, and provides examples of the value of this work.
Single nucleotide polymorphism discovery in bovine liver using RNA-seq technology
Pareek, Chandra Shekhar; Błaszczyk, Paweł; Dziuba, Piotr; Czarnik, Urszula; Fraser, Leyland; Sobiech, Przemysław; Pierzchała, Mariusz; Feng, Yaping; Kadarmideen, Haja N.; Kumar, Dibyendu
2017-01-01
Background RNA-seq is a useful next-generation sequencing (NGS) technology that has been widely used to understand mammalian transcriptome architecture and function. In this study, a breed-specific RNA-seq experiment was utilized to detect putative single nucleotide polymorphisms (SNPs) in liver tissue of young bulls of the Polish Red, Polish Holstein-Friesian (HF) and Hereford breeds, and to understand the genomic variation in the three cattle breeds that may reflect differences in production traits. Results The RNA-seq experiment on bovine liver produced 107,114,4072 raw paired-end reads, with an average of approximately 60 million paired-end reads per library. Breed-wise, a total of 345.06, 290.04 and 436.03 million paired-end reads were obtained from the Polish Red, Polish HF, and Hereford breeds, respectively. Burrows-Wheeler Aligner (BWA) read alignments showed that 81.35%, 82.81% and 84.21% of the mapped sequencing reads were properly paired to the Polish Red, Polish HF, and Hereford breeds, respectively. This study identified 5,641,401 SNPs and insertion and deletion (indel) positions expressed in the bovine liver with an average of 313,411 SNPs and indel per young bull. Following the removal of the indel mutations, a total of 195,3804, 152,7120 and 205,3184 raw SNPs expressed in bovine liver were identified for the Polish Red, Polish HF, and Hereford breeds, respectively. Breed-wise, three highly reliable breed-specific SNP-databases (SNP-dbs) with 31,562, 24,945 and 28,194 SNP records were constructed for the Polish Red, Polish HF, and Hereford breeds, respectively. Using a combination of stringent parameters of a minimum depth of ≥10 mapping reads that support the polymorphic nucleotide base and 100% SNP ratio, 4,368, 3,780 and 3,800 SNP records were detected in the Polish Red, Polish HF, and Hereford breeds, respectively. The SNP detections using RNA-seq data were successfully validated by kompetitive allele-specific PCR (KASPTM) SNP genotyping assay. The comprehensive QTL/CG analysis of 110 QTL/CG with RNA-seq data identified 20 monomorphic SNP hit loci (CARTPT, GAD1, GDF5, GHRH, GHRL, GRB10, IGFBPL1, IGFL1, LEP, LHX4, MC4R, MSTN, NKAIN1, PLAG1, POU1F1, SDR16C5, SH2B2, TOX, UCP3 and WNT10B) in all three cattle breeds. However, six SNP loci (CCSER1, GHR, KCNIP4, MTSS1, EGFR and NSMCE2) were identified as highly polymorphic among the cattle breeds. Conclusions This study identified breed-specific SNPs with greater SNP ratio and excellent mapping coverage, as well as monomorphic and highly polymorphic putative SNP loci within QTL/CGs of bovine liver tissue. A breed-specific SNP-db constructed for bovine liver yielded nearly six million SNPs. In addition, a KASPTM SNP genotyping assay, as a reliable cost-effective method, successfully validated the breed-specific putative SNPs originating from the RNA-seq experiments. PMID:28234981
[Polish historical collection at the University of Edinburgh].
Tomaszewski, W
1995-01-01
The Polish School of Medicine, a joint Scottish-Polish academic enterprise, established in 1941 at the University of Edinburgh for soldiers-students in the Polish Forces, ceased its activity in 1949, four years after the end of the war. Owing to the stalinist terror in occupied Poland most of the 227 graduates remained in the West. There was a deep feeling of gratitude towards the University on the part of the graduates of the Polish School. The 25th anniversary of the School in 1966 was an opportunity to convoke in Edinburgh a world reunion of the graduates. At the academic ceremony two gold medals were presented to the University. The warm reception extended by the University, prompted the resolution to hold quinquennial world reunions in Edinburgh. Since then world reunions were held in Edinburgh every 5 years with meetings with the University authorities and presentation of gifts. By 1980 the number of gifts accumulated to such extent that the seminar room in the Erskine Medical Library was selected for the permanent display of the gifts; this served to intensify the collection of exhibits. Gifts were chosen to remind of certain events in the Polish history of medicine, especially items reflecting Polish links with Scotland. The highest achievement in the Scottish-Polish links, was of course the creation of the Polish School of Medicine. The official opening of the Historical Collection took place in June 1986 on the occasion of a world reunion on the 45th anniversary of the School. It was marked by the unveiling of a memorial plaque. On this ocasion another venture was also initiated: the opening of the Polish School of Medicine Memorial Fund at the University of Edinburgh. It was funded by the graduates to provide scholarship for young doctors from Poland. Another venture was the creation of the "Professor Antoni Jurasz lectureship" for Edinburgh professors to lecture in Medical Academies in Poland. The Historical Collection of the Polish School of Medicine at the University of Edinburgh is a permanent memorial to the magnanimity of the University left by the graduates. It is at the same time a windowshow of a 300 years old Scottish-Polish history of medicine.
Novel cavitation fluid jet polishing process based on negative pressure effects.
Chen, Fengjun; Wang, Hui; Tang, Yu; Yin, Shaohui; Huang, Shuai; Zhang, Guanghua
2018-04-01
Traditional abrasive fluid jet polishing (FJP) is limited by its high-pressure equipment, unstable material removal rate, and applicability to ultra-smooth surfaces because of the evident air turbulence, fluid expansion, and a large polishing spot in high-pressure FJP. This paper presents a novel cavitation fluid jet polishing (CFJP) method and process based on FJP technology. It can implement high-efficiency polishing on small-scale surfaces in a low-pressure environment. CFJP uses the purposely designed polishing equipment with a sealed chamber, which can generate a cavitation effect in negative pressure environment. Moreover, the collapse of cavitation bubbles can spray out a high-energy microjet and shock wave to enhance the material removal. Its feasibility is verified through researching the flow behavior and the cavitation results of the negative pressure cavitation machining of pure water in reversing suction flow. The mechanism is analyzed through a computational fluid dynamics simulation. Thus, its cavitation and surface removal mechanisms in the vertical CFJP and inclined CFJP are studied. A series of polishing experiments on different materials and polishing parameters are conducted to validate its polishing performance compared with FJP. The maximum removal depth increases, and surface roughness gradually decreases with increasing negative outlet pressures. The surface becomes smooth with the increase of polishing time. The experimental results confirm that the CFJP process can realize a high material removal rate and smooth surface with low energy consumption in the low-pressure environment, together with compatible surface roughness to FJP. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Guilian; Zhou, Xiaoqin; Ma, Peiqun; Wang, Rongqi; Meng, Guangwei; Yang, Xu
2018-01-01
The vibration assisted polishing has widely application fields because of higher machining frequency and better polishing quality, especially the polishing with the non-resonant mode that is regarded as a kind of promising polishing method. This paper reports a novel vibration assisted polishing device, consisting of the flexible hinge mechanism driven by the piezoelectric actuators, which is suitable for polishing planes or curve surfaces with slow curvature. Firstly, the generation methods of vibration trajectory are investigated for the same frequency and different frequency signals' inputs, respectively, and then the types of elliptic and Lissajous's vibration trajectories are generated respectively. Secondly, a flexural mechanism consisting of the right circular flexible hinges and the leaf springs is developed to produce two-dimensional vibration trajectory. Statics and dynamics investigating of this flexible mechanism are finished in detail. The analytical models about input and output compliances of the flexural mechanism are established according to the matrix-based compliance modeling, and the dynamic model of the flexural mechanism based on the Euler-Lagrange equation is also presented. The finite element model of the flexural mechanism was established to carry out the numerical simulation in order to testify the rationality of device design. Finally, the polishing experiment is carried out to prove the effectiveness of the vibration device. The experimental results show that this novel vibration assisted polishing device developed in this study can remove more effectively the cutting marks left by last process and obviously reduce the workpiece surface roughness.
Ethical and Moral Education: A National Case Study of Poland.
ERIC Educational Resources Information Center
Janowski, Andrzej
This study explores the Polish experience in values education. Between the years 1944 and 1989 Polish education was often state controlled with the sole purpose of subjugating education to Marxist-Leninist ideology. Over the years the communist party's dictates varied in intensity. Despite the party's efforts to prescribe ethics, certain values…
The "Metrica Regni" Project: The Polish Experience of EAD
ERIC Educational Resources Information Center
Wajs, Hubert
2005-01-01
The fonds of Crown Chancery Public Register ("Metrica Regni") was chosen for the pilot project to introduce Encoded Archival Description (EAD) because of its historical value, typical archival structure and existing finding aids. The rights and privileges granted by Polish kings were recorded in the Register. The oldest books in the…
Experiences with Dating Aggression and Sexual Coercion among Polish College Students
ERIC Educational Resources Information Center
Doroszewicz, Krystyna; Forbes, Gordon B.
2008-01-01
Dating aggression and sexual coercion were studied in Polish college women (n = 100) and men ( n = 101) using the Revised Conflict Tactics Scales (Straus, Hamby, Boney-McCoy, & Sugarman, 1996). Rates of psychological and physical aggression, sexual coercion, and injury were compared for men and women. Rates of physical aggression, sexual…
Williams, David R.
2009-01-01
Objectives. We examined whether perceived chronic discrimination was related to excess body fat accumulation in a random, multiethnic, population-based sample of US adults. Methods. We used multivariate multinomial logistic regression and logistic regression analyses to examine the relationship between interpersonal experiences of perceived chronic discrimination and body mass index and high-risk waist circumference. Results. Consistent with other studies, our analyses showed that perceived unfair treatment was associated with increased abdominal obesity. Compared with Irish, Jewish, Polish, and Italian Whites who did not experience perceived chronic discrimination, Irish, Jewish, Polish, and Italian Whites who perceived chronic discrimination were 2 to 6 times more likely to have a high-risk waist circumference. No significant relationship between perceived discrimination and the obesity measures was found among the other Whites, Blacks, or Hispanics. Conclusions. These findings are not completely unsupported. White ethnic groups including Polish, Italians, Jews, and Irish have historically been discriminated against in the United States, and other recent research suggests that they experience higher levels of perceived discrimination than do other Whites and that these experiences adversely affect their health. PMID:18923119
Transformation products of clindamycin in moving bed biofilm reactor (MBBR).
Ooi, Gordon T H; Escola Casas, Monica; Andersen, Henrik R; Bester, Kai
2017-04-15
Clindamycin is widely prescribed for its ability to treat a number of common bacterial infections. Thus, clindamycin enters wastewater via human excretion or disposal of unused medication and widespread detection of pharmaceuticals in rivers proves the insufficiency of conventional wastewater treatment plants in removing clindamycin. Recently, it has been discovered that attached biofilm reactors, e.g., moving bed biofilm reactors (MBBRs) obtain a higher removal of pharmaceuticals than conventional sludge wastewater treatment plants. Therefore, this study investigated the capability of MBBRs applied in the effluent of conventional wastewater treatment plants to remove clindamycin. First, a batch experiment was executed with a high initial concentration of clindamycin to identify the transformation products. It was shown that clindamycin can be removed from wastewater by MBBR and the treatment process converts clindamycin into the, possibly persistent, products clindamycin sulfoxide and N-desmethyl clindamycin as well as 3 other mono-oxygenated products. Subsequently, the removal kinetics of clindamycin and the formation of the two identified products were investigated in batch experiments using MBBR carriers from polishing and nitrifying reactors. Additionally, the presence of these two metabolites in biofilm-free wastewater effluent was studied. The nitrifying biofilm reactor had a higher biological activity with k-value of 0.1813 h -1 than the reactor with polishing biofilm (k = 0.0161 h -1 ) which again has a much higher biological activity for removal of clindamycin than of the suspended bacteria (biofilm-free control). Clindamycin sulfoxide was the main transformation product which was found in concentrations exceeding 10% of the initial clindamycin concentration after 1 day of MBBR treatment. Thus, MBBRs should not necessarily be considered as reactors mineralizing clindamycin as they perform transformation reactions at least to some extent. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-01-01
The Polish Country Study Project was initiated in 1992 as a result of the US Country Study Initiative whose objective was to grant the countries -- signatories of the United Nations` Framework Convention on Climate Change -- assistance that will allow them to fulfill their obligations in terms of greenhouse gases (GHG`s) inventory, preparation of strategies for the reduction of their emission, and adapting their economies to the changed climatic conditions. In February 1993, in reply to the offer from the United States Government, the Polish Government expressed interest in participation in this program. The Study proposal, prepared by themore » Ministry of Environmental Protection, Natural Resources and Forestry was presented to the US partner. The program proposal assumed implementation of sixteen elements of the study, encompassing elaboration of scenarios for the strategy of mission reduction in energy sector, industry, municipal management, road transport, forestry, and agriculture, as well as adaptations to be introduced in agriculture, forestry, water management, and coastal management. The entire concept was incorporated in macroeconomic strategy scenarios. A complementary element was the elaboration of a proposal for economic and legal instruments to implement the proposed strategies. An additional element was proposed, namely the preparation of a scenario of adapting the society to the expected climate changes.« less
Stress polishing demonstrator for ELT M1 segments and industrialization
NASA Astrophysics Data System (ADS)
Hugot, Emmanuel; Bernard, Anaïs.; Laslandes, Marie; Floriot, Johan; Dufour, Thibaut; Fappani, Denis; Combes, Jean Marc; Ferrari, Marc
2014-07-01
After two years of research and development under ESO support, LAM and Thales SESO present the results of their experiment for the fast and accurate polishing under stress of ELT 1.5 meter segments as well as the industrialization approach for mass production. Based on stress polishing, this manufacturing method requires the conception of a warping harness able to generate extremely accurate bending of the optical surface of the segments during the polishing. The conception of the warping harness is based on finite element analysis and allowed a fine tuning of each geometrical parameter of the system in order to fit an error budget of 25nm RMS over 300μm of bending peak to valley. The optimisation approach uses the simulated influence functions to extract the system eigenmodes and characterise the performance. The same approach is used for the full characterisation of the system itself. The warping harness has been manufactured, integrated and assembled with the Zerodur 1.5 meter segment on the LAM 2.5meter POLARIS polishing facility. The experiment consists in a cross check of optical and mechanical measurements of the mirrors bending in order to develop a blind process, ie to bypass the optical measurement during the final industrial process. This article describes the optical and mechanical measurements, the influence functions and eigenmodes of the system and the full performance characterisation of the warping harness.
Arc-starting aid for GTA welding
NASA Technical Reports Server (NTRS)
Whiffen, E. L.
1977-01-01
Three-in-one handtool combining arc-gap gage, electrode tip sander, and electrode projection gate, effectively improves initiation on gas tungsten arc (GTA), automatic skate-welding machines. Device effects ease in polishing electrode tips and setting exactly initial arc gap before each weld pass.
[Standard operating procedures in ethic committees].
Czarkowski, Marek
2006-02-01
Polish ethic committees should have to work together in order to maintain and develop high quality standards in the protection of human subjects. Exchanging knowledge, know-how and information polish ethic committees should have to implement standard operating procedures. Procedures should improve quality and proficiency of all types of ethic committee's activities. Standard operating procedures should cover as important problems as conflict of interest, trial's insurance or elections of ethic committees. The opinions of experts who have been reviewing medical research projects for several years may prove to be especially valuable in this setting. Governmental initiatives and creation of forum for polish ethic committees are essential in the effective standardisation, coordination and implementation of procedures in regional ethic committees. These projects need support via public funding from our authorities.
Nd:YOV4 laser polishing on WC-Co HVOF coating
NASA Astrophysics Data System (ADS)
Giorleo, L.; Ceretti, E.; Montesano, L.; La Vecchia, G. M.
2017-10-01
WC/Co coatings are widely applied to different types of components due to their extraordinary performance properties including high hardness and wear properties. In industrial applications High Velocity Oxy-Fuel (HVOF) technique is extensively used to deposit hard metal coatings. The main advantage of HVOF compared to other thermal spray techniques is the ability to accelerate the melted powder particles of the feedstock material at a relatively high velocity, leading to obtain good adhesion and low porosity level. However, despite the mentioned benefits, the surface finish quality of WC-Co HVOF coatings results to be poor (Ra higher than 5 µm) thus a mechanical polishing process is often needed. The main problem is that the high hardness of coating leads the polishing process expensive in terms of time and tool wear; moreover polishing becomes difficult and not always possible in case of limited accessibility of a part, micro dimensions or undercuts. Nowadays a different technique available to improve surface roughness is the laser polishing process. The polishing principle is based on focused radiation of a laser beam that melts a microscopic layer of surface material. Compared to conventional polishing process (as grinding) it ensures the possibility of avoiding tool wear, less pollution (no abrasive or liquids), no debris, less machining time and coupled with a galvo system it results to be more suitable in case of 3D complex workpieces. In this paper laser polishing process executed with a Nd:YOV4 Laser was investigated: the effect of different process parameters as initial coating morphology, laser scan speed and loop cycles were tested. Results were compared by a statistical approach in terms of average roughness along with a morphological analysis carried out by Scanning Electron Microscope (SEM) investigation coupled with EDS spectra.
Development of a Direct Fabrication Technique for Full-Shell X-Ray Optics
NASA Technical Reports Server (NTRS)
Gubarev, M.; Kolodziejczak, J. K.; Griffith, C.; Roche, J.; Smith, W. S.; Kester, T.; Atkins, C.; Arnold, W.; Ramsey, B.
2016-01-01
Future astrophysical missions will require fabrication technology capable of producing high angular resolution x-ray optics. A full-shell direct fabrication approach using modern robotic polishing machines has the potential for producing high resolution, light-weight and affordable x-ray mirrors that can be nested to produce large collecting area. This approach to mirror fabrication, based on the use of the metal substrates coated with nickel phosphorous alloy, is being pursued at MSFC. The design of the polishing fixtures for the direct fabrication, the surface figure metrology techniques used and the results of the polishing experiments are presented.
Dynamic SEM wear studies of tungsten carbide cermets. [friction and wear experiments
NASA Technical Reports Server (NTRS)
Brainard, W. A.; Buckley, D. H.
1975-01-01
Dynamic friction and wear experiments were conducted in a scanning electron microscope. The wear behavior of pure tungsten carbide and composite with 6 and 15 weight percent cobalt binder was examined, and etching of the binder was done to selectively determine the role of the binder in the wear process. Dynamic experiments were conducted as the tungsten carbide (WC) and bonded WC cermet surfaces were transversed by a 50 micron radiused diamond stylus. These studies show that the predominant wear process in WC is fracture initiated by plastic deformation, and the wear of the etched cermets is similar to pure WC. The presence of the cobalt binder reduces both friction and wear. The cementing action of the cobalt reduces granular separation, and promotes a dense polished layer because of its low shear strength film-forming properties. The wear debris generated from unetched surface is approximately the same composition as the bulk.
1989-04-01
strengthened glass. These large parts will be formed in one piece using male and female molds along wit’ pressure tc form the compound curves. The various...shown conclusively that the use of polishing compounds has a detrimental effect on windows and gives rise to many of the initial scratches and embedded... compounds which are perceived to be a cause of premature crazing in service. Alternatively, if polishing is deemed necessary for cosmetic or other
Chwastyk-Kowalczyk, Jolanta
2015-01-01
This article presents the history of establishment, functioning and the role of "Science and Technology"--quarterly of the Association of Polish Engineers in Great Britain--in shaping Polish technical thought in the environment of Polish engineers and technicians living in exile. The analysis of the content of the journal published in London in the years 1958-2008 made it evident that this official scientific organ of Polish technical intelligentsia edited in 500 copies reaches members of engineering, technical and scientific milieu across many continents. Despite the fact that Polish language dominates in the articles and thanks to the interdisciplinary character of their content - science and technology, biology, the humanities, sociology and others--the journal makes it possible for the reader to participate in an intellectual adventure. "Science and Technology" was created in 1958 on the initiative of Eng. Prof. Roman Wajda in Great Britain, with support of other Polish technical associations abroad, and embraced the achievements and organisational life of the Polish technical milieu dispersed around the world. On the basis of the London Society's archive materials and old annual volumes of the journal, the author listed editors-in-chief, composition of editorial committees, collaborators, determined editing costs, changeable periodicity, successive print shops, seats of editorial office that always followed the Association in Great Britain. She also showed the effort of a handful of members of editorial committees, working on a voluntary basis to obtain materials for the journal; the role of the journal linking Polish engineers and technicians in exile and its function as a link with the Country, as well as its role in the sphere of information and propaganda. Finally, the author made an analysis of the journal's content, focusing on categories of articles published in "Science and Technology" in the years 1958-2008. Methods used by the author in the article: archival, analysis of the press content: qualitative and quantitative.
Yang, Hao; Cheng, Haobo; Feng, Yunpeng; Jing, Xiaoli
2018-05-01
Subaperture polishing techniques usually produce rolled edges due to edge effect. The rolled edges, especially those in millimeter scale on small components, are difficult to eliminate using conventional polishing methods. Magnetorheological jet polishing (MJP) offers the possibility of the removal of these structures, owing to its small tool influence function (TIF) size. Hence, we investigate the removal characters of inclined MJP jetting models by means of computational fluid dynamics (CFD) simulations and polishing experiments. A discrete phase model (DPM) is introduced in the simulation to get the influence of abrasive particle concentration on the removal mechanism. Therefore, a more accurate model for MJP removal mechanisms is built. With several critical problems solved, a small bevel-cut-like TIF (B-TIF), which has fine acentric and unimodal characteristics, is obtained through inclined jetting. The B-TIF proves to have little edge effect and is applied in surface polishing of thin rolled edges. Finally, the RMS of the experimental section profile converges from 10.5 nm to 1.4 nm, and the rolled edges are successfully suppressed. Consequently, it is validated that the B-TIF has remarkable ability in the removal of millimeter-scale rolled edges.
NASA Astrophysics Data System (ADS)
Seo, Hyunju; Han, Jeong-Yeol; Kim, Sug-Whan; Seong, Sehyun; Yoon, Siyoung; Lee, Kyungmook; Lee, Haengbok
2015-09-01
Today, CVD SiC mirrors are readily available in the market. However, it is well known to the community that the key surface fabrication processes and, in particular, the material removal characteristics of the CVD SiC mirror surface varies sensitively depending on the shop floor polishing and figuring variables. We investigated the material removal characteristics of CVD SiC mirror surfaces using a new and patented polishing tool called orthogonal velocity tool (OVT) that employs two orthogonal velocity fields generated simultaneously during polishing and figuring machine runs. We built an in-house OVT machine and its operating principle allows for generation of pseudo Gaussian shapes of material removal from the target surface. The shapes are very similar to the tool influence functions (TIFs) of other polishing machine such as IRP series polishing machines from Zeeko. Using two CVD SiC mirrors of 150 mm in diameter and flat surface, we ran trial material removal experiments over the machine run parameter ranges from 12.901 to 25.867 psi in pressure, 0.086 m/sec to 0.147 m/sec in tool linear velocity, and 5 to 15 sec in dwell time. An in-house developed data analysis program was used to obtain a number of Gaussian shaped TIFs and the resulting material removal coefficient varies from 3.35 to 9.46 um/psi hour m/sec with the mean value to 5.90 ± 1.26(standard deviation). We report the technical details of the new OVT machine, of the data analysis program, of the experiments and the results together with the implications to the future development of the OVT machine and process for large CVD SiC mirror surfaces.
Prevalence of absolute pitch: a comparison between Japanese and Polish music students.
Miyazaki, Ken'ichi; Makomaska, Sylwia; Rakowski, Andrzej
2012-11-01
Comparable large-scale surveys including an on-site pitch-naming test were conducted with music students in Japan and Poland to obtain more convincing estimates of the prevalence of absolute pitch (AP) and examine how musical experience relates to AP. Participants with accurate AP (95% correct identification) accounted for 30% of the Japanese music students, but only 7% of the Polish music students. This difference in the performance of pitch naming was related to the difference in musical experience. Participants with AP had begun music training at an earlier age (6 years or earlier), and the average year of commencement of musical training was more than 2 years earlier for the Japanese music students than for the Polish students. The percentage of participants who had received early piano lessons was 94% for the Japanese musically trained students but was 72% for the Polish music students. Approximately one-third of the Japanese musically trained students had attended the Yamaha Music School, where lessons on piano or electric organ were given to preschool children in parallel with fixed-do solfège singing training. Such early music instruction was not as common in Poland. The relationship of AP with early music training is discussed.
NASA Astrophysics Data System (ADS)
Zhang, Chupeng; Zhao, Huiying; Zhu, Xueliang; Zhao, Shijie; Jiang, Chunye
2018-01-01
The chemical mechanical polishing (CMP) is a key process during the machining route of plane optics. To improve the polishing efficiency and accuracy, a CMP model and machine tool were developed. Based on the Preston equation and the axial run-out error measurement results of the m circles on the tin plate, a CMP model that could simulate the material removal at any point on the workpiece was presented. An analysis of the model indicated that lower axial run-out error led to lower material removal but better polishing efficiency and accuracy. Based on this conclusion, the CMP machine was designed, and the ultraprecision gas hydrostatic guideway and rotary table as well as the Siemens 840Dsl numerical control system were incorporated in the CMP machine. To verify the design principles of machine, a series of detection and machining experiments were conducted. The LK-G5000 laser sensor was employed for detecting the straightness error of the gas hydrostatic guideway and the axial run-out error of the gas hydrostatic rotary table. A 300-mm-diameter optic was chosen for the surface profile machining experiments performed to determine the CMP efficiency and accuracy.
Sensory factors affecting female consumers' acceptability of nail polish.
Sun, C; Koppel, K; Adhikari, K
2015-12-01
The objectives of this study were to determine what sensory factors impact consumers' acceptability of nail polishes, to explore how these sensory factors impact consumers' acceptability of nail polishes, to investigate whether there are any consumer segments according to their overall acceptability on different nail polishes and to scrutinize how the consumer segments are related to the sensory factors. Ninety-eight females participated in a nail polish consumer study at Kansas State University. Eight commercial products belonging to four categories - regular (REG), gel (GEL), flake (FLK) and water-based (WAT) - were evaluated. Each nail polish sample was evaluated twice by each participant in two different tasks - a task devoted to applying and evaluating the product and a task devoted to observing the appearance and evaluating the product. Pearson's correlation analysis, analysis of variance (ANOVA), external preference mapping, cluster analysis and internal preference mapping were applied for data analysis. Participants' scores of overall liking of the nail polishes were similar in the application task and in the observation task. In general, participants liked the REG and GEL product samples more than the FLK and WAT samples. Among all the sensory attributes, appearance attributes were the major factors that affected participants' overall liking. Aroma seemed to be a minor factor to participants' overall liking. Some sensory attributes, such as runny, shininess, opacity, spreadability, smoothness, coverage and wet appearance, were found to drive participants' overall acceptability positively, whereas others such as pinhole, fatty-edges, blister, brushlines, pearl-like, flake-protrusion, glittery and initial-drag impacted participants' overall acceptability negatively. Four clusters of participants were identified according to their overall liking scores from both the application task and the observation task. Participants' acceptability, based on different sensory attributes, could help a nail polish manufacturer modify or improve their nail polish formulas. Nail polish manufacturers could use the consumer cluster information to improve their marketing strategies for specific categories of their products and to target their advertising on particular consumer groups. © 2015 Society of Cosmetic Scientists and the Société Française de Cosmétologie.
East Europe Report, Economic and Industrial Affairs
1984-07-12
nonferrous metals plant in Leningrad. We used to visit each other and exchange experience in technology and organization of labor. In the 1970s these...vehicles, so well known on Polish roads, had been manufactured. In turn, it was on the basis of Polish design and technological thought that mobile...termed the infrastructure of cooperation, which assures mutual presentation of products, production potential and scientific and technological
NASA Astrophysics Data System (ADS)
Catrin, R.; Taroux, D.; Cormont, P.; Maunier, C.; Corbineau, T.; Razé, G.; Néauport, J.
2013-09-01
The MegaJoule laser being constructed at the CEA near Bordeaux (France) is designed to focus more than 1 MJ of energy of UV light, on a millimeter scale target in the centre of an experiment chamber. After amplification and transport at the wavelength of 1053 nm, frequency conversion at 351 nm is done with KH2PO4 crystals. The final optic assembly of this system is made up of large fused silica optics, working in transmission, that are used to convey, focus or shape the laser beam. When exposed to fluences of some joules per square centimeter at 351 nm within nanosecond pulse duration, fused silica optics can exhibit localized damage. Damage sites grow exponentially after further laser exposition and therefore dramatically limit the optic lifetime. The nature of the surface finishing process has been established to determine the lifetime of these components under high UV fluences (i.e. more than 5 J/cm2 for 3 ns pulses). Being able to reduce or eliminate the damage initiators such as subsurface cracks present in subsurface damage (SSD) layer of conventionally polished optical components aims this study. Magneto-rheological fluid finishing (MRF) is chosen as a final polishing tool to remove layers of material without inducing further damages. MRF enables to process optics with very small normal stresses applied to the surface during material removal and thus permits the elimination of the residual subsurface cracks. This study offers a better understanding of the efficiency of MRF polishing on the elimination of subsurface cracks in SSD layers.
[Polish legal terms of animal-based research - selected aspects].
Poznański, Paweł; Niedźwiecki, Sławomir
2014-01-01
Animal-based models used in biomedical sciences allow to perform research that, conducted on humans, would be highly problematic because of bioethical and technical issues. Contemporary researchers race can lead to abuse, hence the need for special law regulations regarding this subject. This necessity reflected both in the EU and Polish legislation, and is rooted in the philosophical and moral achievements of Europe. EU legislation in this case takes the form of directives implemented in the legal systems of the member states. Polish tradition of legislative approach to animal-based research is long. In 1959 the wide attempt to regulate this matter was undertaken. Until 2005, the nature of the matter had been regulated by the Polish animal protection law. Currently, details concerning animal-based-research are regulated by the animal experiments law (2005). The elapsed time since enactment allowed doctrine and judicature to reveal capabilities and vulnerabilities of the law.
Lv, Liang; Ma, Ping; Huang, Jinyong; He, Xiang; Cai, Chao; Zhu, Heng
2016-03-20
Laser-induced damage threshold (LIDT) is one important evaluation index for optical glasses applied in large laser instruments which are exposed to high light irradiation flux. As a new kind of precise polishing technology, fluid jet polishing (FJP) has been widely used in generating planar, spherical, and aspherical optics with high-accuracy surfaces. Laser damage resistances of fused silica optics by the FJP process are studied in this paper. Fused silica samples with various FJP parameters are prepared, and laser damage experiments are performed with 351 nm wavelength and a 5.5 ns pulse width laser. Experimental results demonstrate that the LIDT of the samples treated with FJP processes did not increase, compared to their original state. The surface quality of the samples is one factor for the decrease of LIDT. For ceria solution polished samples, the cerium element remaining is another factor of the lower LIDT.
Carneiro, Pma; Ramos, T M; de Azevedo, C S; de Lima, E; de Souza, Shj; Turbino, M L; Cesar, P F; Matos, A B
The aim of this study was to evaluate the influence of finishing and polishing systems and toothbrush abrasion on transmittance (T) and surface roughness (Ra) of three composite resins (Filtek Z350 XT, Tetric N-Ceram, and IPS Empress Direct). Eighteen resin disks (10 mm diameter × 2 mm thick) finished by polyester strips had initial surface smoothness recorded, representing phase 1 (P1). Specimens were divided into three groups (n=6) according to the finishing/polishing instrument used (OneGloss, TopGloss, and Sof-Lex) to compose phase 2 samples (P2). Then specimens were subjected to 514 cycles of toothbrush simulation using a toothpaste slurry, with a constant load applied to soft bristles, and were then washed (phase 3=P3). After each phase, the specimens were examined by an optical profiler and spectrophotometer to measure Ra and T. Data were analyzed by analysis of variance, Tukey and Pearson tests. T values were statistically influenced by composite resin ( p=0.000) and phase of measurement ( p=0.000) factors, while the finishing/polishing system used ( p=0.741) did not affect T. On the other hand, Ra values were statistically affected by the factor finishing/polishing system ( p=0.000), but not by composite resin ( p=0.100) and phase of measurement ( p=0.451). Tetric N-Ceram and Empress Direct presented higher values of roughness when polished by OneGloss, while TopGloss and Sof-Lex showed a lower roughness. It can be concluded that composite resins transmitted more light after dental abrasion. Transmittance of composite resins was not modified by the distinct roughness created by finishing/polishing instruments.
Path planning and parameter optimization of uniform removal in active feed polishing
NASA Astrophysics Data System (ADS)
Liu, Jian; Wang, Shaozhi; Zhang, Chunlei; Zhang, Linghua; Chen, Huanan
2015-06-01
A high-quality ultrasmooth surface is demanded in short-wave optical systems. However, the existing polishing methods have difficulties meeting the requirement on spherical or aspheric surfaces. As a new kind of small tool polishing method, active feed polishing (AFP) could attain a surface roughness of less than 0.3 nm (RMS) on spherical elements, although AFP may magnify the residual figure error or mid-frequency error. The purpose of this work is to propose an effective algorithm to realize uniform removal of the surface in the processing. At first, the principle of the AFP and the mechanism of the polishing machine are introduced. In order to maintain the processed figure error, a variable pitch spiral path planning algorithm and the dwell time-solving model are proposed. For suppressing the possible mid-frequency error, the uniformity of the synthesis tool path, which is generated by an arbitrary point at the polishing tool bottom, is analyzed and evaluated, and the angular velocity ratio of the tool spinning motion to the revolution motion is optimized. Finally, an experiment is conducted on a convex spherical surface and an ultrasmooth surface is finally acquired. In conclusion, a high-quality ultrasmooth surface can be successfully obtained with little degradation of the figure and mid-frequency errors by the algorithm.
Neme, A L; Frazier, K B; Roeder, L B; Debner, T L
2002-01-01
Many polishing protocols have been evaluated in vitro for their effect on the surface roughness of restorative materials. These results have been useful in establishing protocols for in vivo application. However, limited research has focused on the subsequent care and maintenance of esthetic restorations following their placement. This investigation evaluated the effect of five polishing protocols that could be implemented at recall on the surface roughness of five direct esthetic restorative materials. Specimens (n=25) measuring 8 mm diameter x 3 mm thick were fabricated in an acrylic mold using five light-cured resin-based materials (hybrid composite, microfilled composite, packable composite, compomer and resin-modified glass ionomer). After photopolymerization, all specimens were polished with Sof-Lex Disks to produce an initial (baseline) surface finish. All specimens were then polished with one of five prophylactic protocols (Butler medium paste, Butler coarse paste, OneGloss, SuperBuff or OneGloss & SuperBuff). The average surface roughness of each treated specimen was determined from three measurements with a profilometer (Surface 1). Next, all specimens were brushed 60,000 times at 1.5 Hz using a brush-head force of 2 N on a Manly V-8 cross-brushing machine in a 50:50 (w/w) slurry of toothpaste and water. The surface roughness of each specimen was measured after brushing (Surface 2) followed by re-polishing with one of five protocols, then final surface roughness values were determined (Surface 3). The data were analyzed using repeated measures ANOVA. Significant differences (p=0.05) in surface roughness were observed among restorative materials and polishing protocols. The microfilled and hybrid resin composite yielded significantly rougher surfaces than the other three materials following tooth brushing. Prophylactic polishing protocols can be used to restore a smooth surface on resin-based esthetic restorative materials following simulated tooth brushing.
Oleszczyk, Marek; Krztoń-Królewiecka, Anna; Schäfer, Willemijn L A; Boerma, Wienke G W; Windak, Adam
2017-11-22
Patients as real healthcare system users are important observers of primary care and are able to provide reliable information about the quality of care. The aim of this study was to explore the patients' experiences and their level of satisfaction with the process and outcomes of care provided by primary care physicians in Poland and to identify the characteristics of the patients, their physicians, and facilities associated with patient satisfaction. The study is based on data from the Polish part of the Quality and Costs of Primary Care in Europe (QUALICOPC) cross-sectional, questionnaire-based study. In Poland, a nationally representative sample of 220 PC physicians and 1980 of their patients were recruited to take part in the study. As a study tool we used 3 out of 4 QUALICOPC questionnaires: "Patient Experience", "PC Physician" and "Fieldworker" questionnaires. The areas of the best quality perceived by Polish PC patients are: equity, accessibility of care and quality of service. Coordination and comprehensiveness of care are evaluated relatively worse. The patients' and their physicians' characteristics have a limited influence on patient satisfaction and experiences with Polish primary care. Primary health care in Poland is of good overall quality as perceived by the patients. Study participants were at most satisfied with accessibility and equity of care and less satisfied with coordination and comprehensiveness of care. Longer patient-doctor relationship and older age of patients were found as the most influential determinants of higher satisfaction. However, variables used in this study poorly explain the overall level of satisfaction. Further research is needed to identify the other determinants of patient satisfaction in the Polish population. Rural practices deserve additional attention due to highest proportions of both extremely satisfied and dissatisfied patients.
Wiese, Richard; Orzechowska, Paula; Alday, Phillip M.; Ulbrich, Christiane
2017-01-01
Phonological knowledge of a language involves knowledge about which segments can be combined under what conditions. Languages vary in the quantity and quality of licensed combinations, in particular sequences of consonants, with Polish being a language with a large inventory of such combinations. The present paper reports on a two-session experiment in which Polish-speaking adult participants learned nonce words with final consonant clusters. The aim was to study the role of two factors which potentially play a role in the learning of phonotactic structures: the phonological principle of sonority (ordering sound segments within the syllable according to their inherent loudness) and the (non-) existence as a usage-based phenomenon. EEG responses in two different time windows (adversely to behavioral responses) show linguistic processing by native speakers of Polish to be sensitive to both distinctions, in spite of the fact that Polish is rich in sonority-violating clusters. In particular, a general learning effect in terms of an N400 effect was found which was demonstrated to be different for sonority-obeying clusters than for sonority-violating clusters. Furthermore, significant interactions of formedness and session, and of existence and session, demonstrate that both factors, the sonority principle and the frequency pattern, play a role in the learning process. PMID:28119642
Refractive index sensing by Brillouin scattering in side-polished optical fibers.
Bernini, Romeo; Persichetti, Gianluca; Catalano, Ester; Zeni, Luigi; Minardo, Aldo
2018-05-15
In this Letter, we demonstrate the possibility to measure the refractive index of a liquid, using the stimulating Brillouin scattering in a 3-cm-long side-polished optical fiber. In addition, we show that by depositing a high-refractive index layer on the polished surface the sensitivity of the Brillouin frequency shift (BFS) can be increased due to a higher penetration of the evanescent field in the outer medium. Experiments show a maximum BFS change of about 11 MHz when varying the refractive index of the external medium from 1 (air) to 1.402, and a BFS sensitivity to refractive index of about 293 MHz/RIU around 1.40.
ERIC Educational Resources Information Center
Kopacz, Marek S.; Bajka-Kopacz, Aleksandra
2012-01-01
Almost all teenage magazines invite readers to submit questions concerning relationships, published as letters to the editor, popularly called "advice columns," often containing explicit questions about sexuality. This study aims to examine, firstly, how themes related to sexual initiation are presented in letters to the editor published…
Zhou, Jianying; Deng, Jiupeng; Li, Jinyuan; Wang, Jide; Shen, Baolian
2016-05-01
To evaluate the influence of different polishing methods on marginal microleakage of zirconium dioxide full crown. Thirty extracted premolars were selected and randomly divided into three groups, A, B and C, with 10 in each group. Group A was prepared with MANI TF-13 bur completely without the treatment of shoulder. The shoulder of group B was polished with MANI TR13-EF bur after the preparation using MANI TF-13. The shoulder of group C was polished with the dental pneumatic ultrasonic hand-piece of KaVo SONICflex after the preparation using MANI TF-13 bur. Five specimens after preparation were selected in each group. Fifteen CAD/CAM zirconium dioxide full crowns have been made. The crowns were bonded using PULPDENT resin cement, and the root canals were sealed using nail polish, and apical foramen were closed using flow resin. The test-pieces have been immersed in a 3% solution of methylene blue for 24 h. The condition of shoulder marginal microleakage was observed using light stereomicroscopy and evaluated in classification index. The remaining specimens in each group were used for roughness test and scanning electron microscope(SEM) experiment. The marginal microleakage situations of specimens in three groups was analyzed by SPSS 17.0. The enamel surface of different polishing methods was observed using SEM. The specimens in group C demonstrated the least marginal microleakage, and those in group B showed an intermediate level of marginal microleakage, and those in group A characterized the most serious marginal microleakage (total, χ2=44.610, P<0.01; among the different groups, P<0.05). The roughness experiment showed that specimens in group C achieve the smoothest results ([0.27±0.03] μm). Preparation shoulder polished using the dental pneumatic ultrasonic hand-piece demonstrated the best result under the SEM among the three groups. The anti-microleakage effectiveness of dental pneumatic ultrasonic hand-piece in shoulder refinement is better than ordinary shoulder treatment.
Paruch, A M; Mæhlum, T; Obarska-Pempkowiak, H; Gajewska, M; Wojciechowska, E; Ostojski, A
2011-01-01
This article describes Norwegian and Polish experiences concerning domestic wastewater treatment obtained during nearly 20 years of operation for constructed wetland (CW) systems in rural areas and scattered settlements. The Norwegian CW systems revealed a high performance with respect to the removal of organic matter, biogenic elements and faecal indicator bacteria. The performance of the Polish CW systems was unstable, and varied between unsatisfied and satisfied treatment efficiency provided by horizontal and vertical flow CWs, respectively. Therefore, three different concepts related to the improvement of CW technology have been developed and implemented in Poland. These concepts combined some innovative solutions originally designed in Norway (e.g. an additional treatment step in biofilters) with Polish inspiration for new CWs treating rural domestic wastewater. The implementation of full-scale systems will be evaluated with regard to treatment efficiency and innovative technology; based on this, a further selection of the most favourable CW for rural areas and scattered settlements will be performed.
Kao, Chung-Shan; Dietrich, Rainer; Sommer, Werner
2010-01-01
Background Languages differ in the marking of the sentence mood of a polar interrogative (yes/no question). For instance, the interrogative mood is marked at the beginning of the surface structure in Polish, whereas the marker appears at the end in Chinese. In order to generate the corresponding sentence frame, the syntactic specification of the interrogative mood is early in Polish and late in Chinese. In this respect, German belongs to an interesting intermediate class. The yes/no question is expressed by a shift of the finite verb from its final position in the underlying structure into the utterance initial position, a move affecting, hence, both the sentence's final and the sentence's initial constituents. The present study aimed to investigate whether during generation of the semantic structure of a polar interrogative, i.e., the processing preceding the grammatical formulation, the interrogative mood is encoded according to its position in the syntactic structure at distinctive time points in Chinese, German, and Polish. Methodology/Principal Findings In a two-choice go/nogo experimental design, native speakers of the three languages responded to pictures by pressing buttons and producing utterances in their native language while their brain potentials were recorded. The emergence and latency of lateralized readiness potentials (LRP) in nogo conditions, in which speakers asked a yes/no question, should indicate the time point of processing the interrogative mood. The results revealed that Chinese, German, and Polish native speakers did not differ from each other in the electrophysiological indicator. Conclusions/Significance The findings suggest that the semantic encoding of the interrogative mood is temporally consistent across languages despite its disparate syntactic specification. The consistent encoding may be ascribed to economic processing of interrogative moods at various sentential positions of the syntactic structures in languages or, more generally, to the overarching status of sentence mood in the semantic structure. PMID:20927373
NASA Technical Reports Server (NTRS)
Vilnrotter, V.
2011-01-01
The potential development of large aperture ground?based "photon bucket" optical receivers for deep space communications has received considerable attention recently. One approach currently under investigation is to polish the aluminum reflector panels of 34?meter microwave antennas to high reflectance, and accept the relatively large spotsize generated by state of?the?art polished aluminum panels. Theoretical analyses of receiving antenna pointing, temporal synchronization and data detection have been addressed in previous papers. Here we describe the experimental effort currently underway at the Deep Space Network (DSN) Goldstone Communications Complex in California, to test and verify these concepts in a realistic operational environment. Two polished aluminum panels (a standard DSN panel polished to high reflectance, and a custom designed aluminum panel with much better surface quality) have been mounted on the 34 meter research antenna at Deep?Space Station 13 (DSS?13), and a remotely controlled CCD camera with a large CCD sensor in a weather?proof container has been installed next to the subreflector, pointed directly at the custom polished panel. The point?spread function (PSF) generated by the Vertex polished panel has been determined to be smaller than the sensor of the CCD camera, hence a detailed picture of the PSF can be obtained every few seconds, and the sensor array data processed to determine the center of the intensity distribution. In addition to estimating the center coordinates, expected communications performance can also been evaluated with the recorded data. The results of preliminary pointing experiments with the Vertex polished panel receiver using the planet Jupiter to simulate the PSF generated by a deep?space optical transmitter are presented and discussed in this paper.
Fundamental studies on silicon dioxide chemical mechanical polishing
NASA Astrophysics Data System (ADS)
Mahajan, Uday
Chemical Mechanical Polishing (CMP) has lately been adopted on a large scale by the semiconductor industry for planarizing and patterning metal and dielectric films. Additionally, CMP has been used for hundreds of years for optical polishing. Still, several aspects of this process remain poorly understood. In this study, some results on CMP of SiO2 are presented with a view to characterizing the effects of abrasive properties and slurry chemistry on the polishing process. Additionally, some results from a novel in-situ friction force measuring instrument are also presented. The friction force results showed the effect of several parameters such as surface roughness, solution pH and ionic strength on wafer-pad interactions. Additionally, monitoring the friction as a function of velocity showed that the transition from boundary lubrication to full fluid-film lubrication depends on the roughness (conditioning) of the polishing pad. The parameters investigated in the polishing experiments include abrasive size and concentration. From the experimental results, it was found that an optimum concentration exists for each abrasive size, which shifts to lower values and becomes narrower as particle size increases. From calculations, this was attributed to a decreased ability of the large particles to chemically modify the surface of the SiO2 films. The smaller particles, having a much larger surface area, are able to better adsorb dissolution and abrasion products at high concentrations, thus leading to high removal rates under those conditions. Studies on the effect of slurry ionic strength showed that the ability of a metal ion to shield the surface charge on the surfaces interacting during polishing is what determined removal rate. This was due to the reduced electrostatic repulsion between the surfaces, which resulted in better contact and thus higher polishing rates. These results were corroborated by the earlier friction force measurements. Finally, the influence of particle density on polishing was shown, with denser alumina particles being able to polish SiO2 much more effectively. Some preliminary results on polishing with different abrasives as a function of slurry pH indicate that the material properties of the abrasives seem to change around their Iso-electric Points (IEP), resulting in almost no polishing, and severe particle contamination on the SiO2 surface.
Dynamic evolution of interface roughness during friction and wear processes.
Kubiak, K J; Bigerelle, M; Mathia, T G; Dubois, A; Dubar, L
2014-01-01
Dynamic evolution of surface roughness and influence of initial roughness (S(a) = 0.282-6.73 µm) during friction and wear processes has been analyzed experimentally. The mirror polished and rough surfaces (28 samples in total) have been prepared by surface polishing on Ti-6Al-4V and AISI 1045 samples. Friction and wear have been tested in classical sphere/plane configuration using linear reciprocating tribometer with very small displacement from 130 to 200 µm. After an initial period of rapid degradation, dynamic evolution of surface roughness converges to certain level specific to a given tribosystem. However, roughness at such dynamic interface is still increasing and analysis of initial roughness influence revealed that to certain extent, a rheology effect of interface can be observed and dynamic evolution of roughness will depend on initial condition and history of interface roughness evolution. Multiscale analysis shows that morphology created in wear process is composed from nano, micro, and macro scale roughness. Therefore, mechanical parts working under very severe contact conditions, like rotor/blade contact, screws, clutch, etc. with poor initial surface finishing are susceptible to have much shorter lifetime than a quality finished parts. © Wiley Periodicals, Inc.
REOSC approach to ELTs and segmented optics
NASA Astrophysics Data System (ADS)
Geyl, Roland; Cayrel, Marc
2000-07-01
On the basis of its experience gained on the VLT and GEMINI primary mirrors polishing REOSC will present his first comments on the preliminary technical specifications of some concepts (OWL, MAXAT) discussed with their instigators (ESO, AURA). Similarities with other projects presently running (CEA LIL) at REOSC that lead to consider such type of giant telescope with some unsuspected serenity. In addition the discussion will be illustrated with the REOSC experience in medium and large size off axis aspheric optics fabrication, the most recent being the Gran Telescopio Canaries project for which REOSC has just been awarded by GRANTECAN S.A. for polishing the 36 segments of this 11-m instrument.
Factors Influencing Material Removal And Surface Finish Of The Polishing Of Silica Glasses
2006-01-01
Mechanical Properties of Quartz and Zerodur ® ..................................... 48 TABLE 4.2: Results from variable load and lap velocity experiments...of glass and glass-ceramic substrates which are used in a vast amount of applications, from optics for lithographic machines to mirrors and lenses...SiO2) glass polishing with metal oxide abrasive particles. This scheme will mirror the experimentation in this thesis, and hopefully provide a better
Implementation of Satellite Techniques in the Air Transport
NASA Astrophysics Data System (ADS)
Fellner, Andrzej; Jafernik, Henryk
2016-06-01
The article shows process of the implementation satellite systems in Polish aviation which contributed to accomplishment Performance-Based Navigation (PBN) concept. Since 1991 authors have introduced Satellite Navigation Equipment in Polish Air Forces. The studies and researches provide to the Polish Air Force alternative approaches, modernize their navigation and landing systems and achieve compatibility with systems of the North Atlantic Treaty Organization (NATO) and International Civil Aviation Organization (ICAO). Acquired experience, conducted military tests and obtained results enabled to take up work scientifically - research in the environment of the civil aviation. Therefore in 2008 there has been launched cooperation with Polish Air Navigation Services Agency (PANSA). Thanks to cooperation, there have been compiled and fulfilled three fundamental international projects: EGNOS APV MIELEC (EGNOS Introduction in European Eastern Region - APV Mielec), HEDGE (Helicopters Deploy GNSS in Europe), SHERPA (Support ad-Hoc to Eastern Region Pre-operational in GNSS). The successful completion of these projects enabled implementation 21 procedures of the RNAV GNSS final approach at Polish airports, contributing to the implementation of PBN in Poland as well as ICAO resolution A37-11. Results of conducted research which served for the implementation of satellite techniques in the air transport constitute the meaning of this material.
Social Interest in The Polish Doctrine of Monument Preservation
NASA Astrophysics Data System (ADS)
Antoszczyszyn, Marek
2017-10-01
The paper discusses a controversy surrounding the latest amendment to the text of the Polish Parliament Act Conservation and the Care of Monuments (2015). It is a common dictum that any edifice cannot exist without good foundations. In this particular case of the mentioned above Act, definition of monument appears to be such a basis. A social interest is one of the constituent elements of the definition mentioned above. In the first part of the paper the notion of the social interest expression has been discussed, particularly from national and international points of view. The second part of the paper comprises some examples from the Polish monument preservation experience with the use of comparison method supported by case study. Only three big Polish cities: Warsaw, Wroclaw and Szczecin are involved in the presented case study but it must be emphasized that many other places on Polish territory experienced the same. Basing on the faith of these cities, the results and discussion chapter proves fundamental discrepancy in social interest notion between national and international scopes using some analytical methods. Finally, in the discussion chapter some proposals for the future amendment of monument definition in the Act of Conservation and the Care of Monuments have been provided.
Dwell-time algorithm for polishing large optics.
Wang, Chunjin; Yang, Wei; Wang, Zhenzhong; Yang, Xu; Hu, Chenlin; Zhong, Bo; Guo, Yinbiao; Xu, Qiao
2014-07-20
The calculation of the dwell time plays a crucial role in polishing precision large optics. Although some studies have taken place, it remains a challenge to develop a calculation algorithm which is absolutely stable, together with a high convergence ratio and fast solution speed even for extremely large mirrors. For this aim, we introduced a self-adaptive iterative algorithm to calculate the dwell time in this paper. Simulations were conducted in bonnet polishing (BP) to test the performance of this method on a real 430 mm × 430 mm fused silica part with the initial surface error PV=1741.29 nm, RMS=433.204 nm. The final surface residual error in the clear aperture after two simulation steps turned out to be PV=11.7 nm, RMS=0.5 nm. The results confirm that this method is stable and has a high convergence ratio and fast solution speed even with an ordinary computer. It is notable that the solution time is usually just a few seconds even on a 1000 mm × 1000 mm part. Hence, we believe that this method is perfectly suitable for polishing large optics. And not only can it be applied to BP, but it can also be applied to other subaperture deterministic polishing processes.
NASA Astrophysics Data System (ADS)
Yang, Minghong; Qi, Hongji; Zhao, Yuanan; Yi, Kui
2012-01-01
The 355 nm laser-induced damage thresholds (LIDTs) of polished fused silica with and without the residual subsurface cracks were explored. HF based wet etching and magnetorheological finishing was used to remove the subsurface cracks. To isolate the effect of subsurface cracks, chemical leaching was used to eliminate the photoactive impurities in the polishing layer. Results show that the crack number density decreased from~103 to <1cm-2, and the LIDT was improved as high as 2.8-fold with both the subsurface cracks and the polishing layer being removed. Subsurface cracks play a significant role in laser damage at fluencies between 15~31 J/cm2 (355nm, 8ns). HF Etching of the cracks was shown to increase the damage performance as nearly high as that of the samples in which subsurface cracks are well controlled.
Investigation of Al Coated Mg for Biomedical Applications
NASA Astrophysics Data System (ADS)
Elmrabet, Nabila; Roe, Martin; Neate, Nigel; Grant, David M.; Brown, Paul D.
The corrosion resistant properties of 1-2 μm thick Al coatings deposited by radio frequency magnetron sputtering on polished Mg surfaces, within Ar and Ar/H2 environments, have been appraised. The coatings were heat-treated at 300°C for 5 h to induce the formation of bioinert Al2O3, and samples were corroded within phosphate buffered saline solution at 37°C to mimic the biological environment. Both the as-deposited and heat-treated coatings were found to delay the onset of corrosion, but showed higher initial corrosion rates, once established, as compared with polished Mg surfaces. Slightly improved performance of the coatings was achieved through the addition of H2 to the system which acted to inhibit Al-Mg alloying and MgO formation. However, localized accelerated corrosion associated with substrate polishing damage emphasized the need for improved process control and coating uniformity.
Dynamic SEM wear studies of tungsten carbide cermets
NASA Technical Reports Server (NTRS)
Brainard, W. A.; Buckley, D. H.
1975-01-01
Dynamic friction and wear experiments were conducted in a scanning electron microscope. The wear behavior of pure tungsten carbide and composite with 6 and 15 weight percent cobalt binder was examined. Etching of the binder was done to selectively determine the role of the binder in the wear process. Dynamic experiments were conducted as the WC and bonded WC cermet surfaces were transversed by a 50 micron radiused diamond stylus. These studies show that the predominant wear process in WC is fracture initiated by plastic deformation. The wear of the etched cermets is similar to pure WC. The presence of the cobalt binder reduces both friction and wear. The cementing action of the cobalt reduces granular separation and promotes a dense polished layer because of its low shear strength film-forming properties. The wear debris generated from unetched surface is approximately the same composition as the bulk.
[Fifty years of the Polish School of Medicine at the University of Edinburgh (1941-1991)].
Tomaszewski, W
1994-01-01
The Polish School of Medicine at the University of Edinburgh started in 1941 on the initiative of the University. It was destined for soldier-students in the Polish Forces in Great Britain. This academic institution, unique in the history of universities, was a joint Scottish-Polish enterprise. An Agreement was concluded between the Polish Government in London and the University of Edinburgh. The School was an independent Polish academic institution and, at the same time, an integral part of the University of Edinburgh. The students matriculated at the University. The University provided all the laboratory and clinical facilities necessary for teaching. Due to a lack of Polish professors for some chairs a few of them were held by Scottish professors. Attached to them were Polish lecturers but the examinations were then held in English. The diploma, originally valid only in Poland, became recognised in Great Britain following an Act of Parliament in 1947. There were 337 students, a number of them women. 227 obtained the degree M.B., Ch.B. The war ended in 1945. The School continued up till 1949. Poland was not free. The Nazi occupation of Poland was replaced by Soviet domination which was to last for over 40 years. Only 22 of the graduates returned home, about 100 settled in G. Britain, another 100 dispersed world wide. The "magnanimous gesture" of the University of Edinburgh was thereafter remembered with gratitude by the members of the Polish School. In 1961, on the occasion of the 20th anniversary of the School, the first reunion of the graduates was organised in Birmingham for those settled in Gr. Britain. The success of the reunion prompted decision on organising annual "English" gatherings of the Polish graduates in Gr. Britain. The first world reunion of the graduates took place in Edinburgh in 1966, attracting a large number of participants on this occasion of the 25th anniversary of the School. That immensely successful anniversary of the Polish School which was celebrated by the University, influenced the participants to organise regular quinquennial world reunions in Edinburgh. A later, particularly memorable event, was the world reunion in 1976 on the occasion of the 250th anniversary of the Medical Faculty of the University; it was celebrated jointly, as it coincided with the 35th anniversary of the Polish School. The 45th anniversary of the School in 1986 was marked by the opening of the "Polish School of Medicine Historical Collection" in the Polish Room of the Erskine Medical Library of the University of Edinburgh. Also a Polish School of Medicine Memorial Fund, founded on contributions from the graduates, was inaugurated at the University of Edinburgh to provide scholarships for research workers from Poland. Another venture was the "Professor Antoni Jurasz Lectureship" for professors of the Edinburgh Medical Faculty to promote contact with Medical Schools in Poland by delivering lectures. An ardent desire was expressed by the original organisers of the School to continue into the future the academic links in medicine between the University and Poland. Political and ideological factors which devided the post-war Europe did not favor such a fulfillment of this plan. The members of the School who remained in the West, maintained links with the University and prepared funds to put the plans of co-operation into action. With the end of the political division of Europe the future of a productive Scottish-Polish collaboration can be viewed with hope and confidence.
Ion-beam assisted laser fabrication of sensing plasmonic nanostructures
Kuchmizhak, Aleksandr; Gurbatov, Stanislav; Vitrik, Oleg; Kulchin, Yuri; Milichko, Valentin; Makarov, Sergey; Kudryashov, Sergey
2016-01-01
Simple high-performance, two-stage hybrid technique was developed for fabrication of different plasmonic nanostructures, including nanorods, nanorings, as well as more complex structures on glass substrates. In this technique, a thin noble-metal film on a dielectric substrate is irradiated by a single tightly focused nanosecond laser pulse and then the modified region is slowly polished by an accelerated argon ion (Ar+) beam. As a result, each nanosecond laser pulse locally modifies the initial metal film through initiation of fast melting and subsequent hydrodynamic processes, while the following Ar+-ion polishing removes the rest of the film, revealing the hidden topography features and fabricating separate plasmonic structures on the glass substrate. We demonstrate that the shape and lateral size of the resulting functional plasmonic nanostructures depend on the laser pulse energy and metal film thickness, while subsequent Ar+-ion polishing enables to vary height of the resulting nanostructures. Plasmonic properties of the fabricated nanostructures were characterized by dark-field micro-spectroscopy, Raman and photoluminescence measurements performed on single nanofeatures, as well as by supporting numerical calculations of the related electromagnetic near-fields and Purcell factors. The developed simple two-stage technique represents a new step towards direct large-scale laser-induced fabrication of highly ordered arrays of complex plasmonic nanostructures. PMID:26776569
Evaluation of CVD silicon carbide for synchrotron radiation mirrors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takacs, P.Z.
1981-07-01
Chemical vapor deposited silicon carbide (CVD SiC) is a recent addition to the list of materials suitable for use in the harsh environment of synchrotron radiation (SR) beam lines. SR mirrors for use at normal incidence must be ultrahigh vacuum compatible, must withstand intense x-ray irradiation without surface damage, must be capable of being polished to an extremely smooth surface finish, and must maintain surface figure under thermal loading. CVD SiC exceeds the performance of conventional optical materials in all these areas. It is, however, a relatively new optical material. Few manufacturers have experience in producing optical quality material, andmore » few opticians have experience in figuring and polishing the material. The CVD material occurs in a variety of forms, sensitively dependent upon reaction chamber production conditions. We are evaluating samples of CVD SiC obtained commercially from various manufacturers, representing a range of deposition conditions, to determine which types of CVD material are most suitable for superpolishing. At the time of this writing, samples are being polished by several commercial vendors and surface finish characteristics are being evaluated by various analytical methods.« less
Evaluation of CVD silicon carbide for synchrotron radiation mirrors
NASA Astrophysics Data System (ADS)
Takacs, Peter Z.
1982-04-01
Chemical vapor deposited silicon carbide (CVD SiC) is a recent addition to the list of materials suitable for use in the harsh environment of synchrotron radiation (SR) beam lines. SR mirrors for use at normal incidence must be ultrahigh vacuum compatible, must withstand intense X-ray irradiation without surface damage, must be capable of being polished to an extremely smooth surface finish, and must maintain surface figure under thermal loading. CVD SiC exceeds the performance of conventional optical materials in all these areas. It is, however, a relatively new optical material. Few manufacturers have experience in producing optical quality material, and few opticians have experience in figuring and polishing the material. The CVD material occurs in a variety of forms, sensitively dependent upon reaction chamber production conditions. We are evaluating samples of CVD SiC obtained commercially from various manufacturers, representing a range of deposition conditions, to determine which types of CVD material are most suitable for superpolishing. At the time of this writing, samples are being polished by several commercial vendors and surface finish characteristics are being evaluated by various analytical methods.
Framework for assessing key variable dependencies in loose-abrasive grinding and polishing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, J.S.; Aikens, D.M.; Brown, N.J.
1995-12-01
This memo describes a framework for identifying all key variables that determine the figuring performance of loose-abrasive lapping and polishing machines. This framework is intended as a tool for prioritizing R&D issues, assessing the completeness of process models and experimental data, and for providing a mechanism to identify any assumptions in analytical models or experimental procedures. Future plans for preparing analytical models or performing experiments can refer to this framework in establishing the context of the work.
Reduced cost and improved figure of sapphire optical components
NASA Astrophysics Data System (ADS)
Walters, Mark; Bartlett, Kevin; Brophy, Matthew R.; DeGroote Nelson, Jessica; Medicus, Kate
2015-10-01
Sapphire presents many challenges to optical manufacturers due to its high hardness and anisotropic properties. Long lead times and high prices are the typical result of such challenges. The cost of even a simple 'grind and shine' process can be prohibitive. The high precision surfaces required by optical sensor applications further exacerbate the challenge of processing sapphire thereby increasing cost further. Optimax has demonstrated a production process for such windows that delivers over 50% time reduction as compared to traditional manufacturing processes for sapphire, while producing windows with less than 1/5 wave rms figure error. Optimax's sapphire production process achieves significant improvement in cost by implementation of a controlled grinding process to present the best possible surface to the polishing equipment. Following the grinding process is a polishing process taking advantage of chemical interactions between slurry and substrate to deliver excellent removal rates and surface finish. Through experiments, the mechanics of the polishing process were also optimized to produce excellent optical figure. In addition to reducing the cost of producing large sapphire sensor windows, the grinding and polishing technology Optimax has developed aids in producing spherical sapphire components to better figure quality. In addition to reducing the cost of producing large sapphire sensor windows, the grinding and polishing technology Optimax has developed aids in producing spherical sapphire components to better figure quality. Through specially developed polishing slurries, the peak-to-valley figure error of spherical sapphire parts is reduced by over 80%.
Lech, Katarzyna; Jarosz, Maciej
2016-05-01
The present work reports a method for identification of Polish cochineal (Porphyrophora polonica L.) in historical fabrics by the use of high-performance liquid chromatography coupled with diode array and tandem mass spectrometric detection with electrospray ionization (HPLC-DAD-ESI MS/MS). This hyphened technique allows detection and identification of 16 new minor colorants present in the discussed scale insect (including two previously observed by Wouters and Verhecken (Ann Soc Entomol Fr. 1989;25:393-410), but specified only as compounds of unknown structures) that do not occur (e.g., in American cochineal). The MS/MS experiments, complemented with UV-VIS data, enable identification of mono- and di-, C- and O-hexosides of kermesic and flavokermesic acids or their derivatives. The present paper introduces a fingerprint of color compounds present in Polish cochineal and defines them, particularly pp6 (ppI, O-hexoside of flavokermesic acid), as its markers allow distinguishing of Polish-cochineal reds from the American ones. Usefulness of the selected set of markers for identification of Polish cochineal has been demonstrated in the examination of textiles from the collection of the National Museum in Warsaw using the multiple reaction monitoring (MRM) method, originally elaborated on the basis of this study.
Maximizing the use of local materials in HMA surfaces.
DOT National Transportation Integrated Search
2012-04-01
One approach to reducing initial construction costs is to maximize the use of locally available aggregates. The main concern with using : locally available carbonate aggregates, however, is that they tend to polish under traffic and provide inadequat...
Paszko, Tadeusz; Jankowska, Monika
2018-06-18
Laboratory adsorption and degradation studies were carried out to determine the effect of time-dependent adsorption on propiconazole degradation rates in samples from three Polish Luvisols. Strong propiconazole adsorption (organic carbon normalized adsorption coefficients K oc in the range of 1217-7777 mL/g) was observed in batch experiments, with a typical biphasic mechanism with a fast initial step followed by the time-dependent step, which finished within 48 h in the majority of soils. The time-dependent step observed in incubation experiments was longer (duration from 5 to 23 d), and its contribution to total adsorption was from 20% to 34%. The half-lives obtained at 25 °C and 40% maximum water holding capacity of soil, were in the range of 34.7-112.9 d in the Ap horizon and in the range of 42.3-448.8 d for subsoils. The very strong correlations, between degradation rates in pore water and soil organic carbon and soil microbial activity, indicated that microbial degradation of propiconazole was most likely the only significant process responsible for the decay of this compound under aerobic conditions for the whole of the examined soil profiles. Modeling of the processes showed that only models coupling adsorption and degradation were able to correctly describe the experimental data. The analysis of the bioavailability factor values showed that degradation was not limited by the rate of propiconazole desorption from soil, but sorption affected the degradation rate by decreasing its availability for microorganisms. Copyright © 2018. Published by Elsevier Inc.
Encountering the past in the present: An exploratory study of educational heritage tourism
NASA Astrophysics Data System (ADS)
Gross, Magdalena H.; Kelman, Ari Y.
2017-02-01
This article presents an educational programme designed to explore the multicultural history of Poland. Targeting Jewish and non-Jewish students of Polish heritage, the Polonia Programme (PP) was conceptualised with the aim of applying the tools of experiential education to initiate a new approach to examining one of the world's most challenging and fraught historical narratives. The programme, piloted in the summer of 2014, takes two groups of young people from the United States to Poland each year. It features a combination of formal lectures and interactive tours, complemented by structured and semi-structured discussions. The destination of this particular tour, with these particular participants, both challenges and reinforces accepted notions of "heritage tourism" within an experiential educational framework. This framework enables a sense of group connectivity which allows students to be, perhaps, more open to alternative narratives about the past. The authors of this article, who were involved in evaluating the pilot launch of the Polonia Programme, found that the programme's experiential approach succeeded in encouraging participants in the pilot cohort to challenge ideas about their definitions of and preconceptions about "who and what counts as Polish". For many, the experience shifted their understanding of Poland towards one which took its multi-ethnic and multicultural history into account. Several discovered new perspectives on their own identity and heritage, while others reached a new understanding of the shared histories of Poles and Jews. The experiential nature of this programme also allowed students to encounter difficult histories: experience, then, became a vehicle for more challenging conversations and deeper learning.
Tomik, Rajmund; Berber, Serkan; Düz, Burak; Çivak, Barış; Çalişkan, Uğur; Ogrodnik, Joanna
2016-01-01
Abstract Motivation is an important phenomenon in the realm of education, particularly in the university fields connected with physical education and sport, where it is necessary to accommodate and balance intellectual abilities and physical fitness. The present study tested motivation levels among university students in the fields connected with physical education and sport in Poland and Turkey. It was based on the Self-Determination Theory (Deci and Ryan, 1985), namely intrinsic motivation, extrinsic motivation and amotivation which impact human behaviour. The Academic Motivation Scale was used (Vallerand et al., 1992). The aims of the study were twofold, first, to crossculturally validate Polish and Turkish versions of the Academic Motivation Scale and second, to identify and compare the motivation to study depending on nationality and gender. Both Polish and Turkish versions of the questionnaire were validated and converted to a four-factorial structure. The findings indicated that Polish and Turkish students’ motivation especially differed in amotivation and intrinsic motivation to know and experience stimulation. Moreover, Turkish female students proved to be at the lowest estimate of amotivation. PMID:28031771
Ardeńska, Agnieszka; Tomik, Rajmund; Berber, Serkan; Düz, Burak; Çivak, Barış; Çalişkan, Uğur; Ogrodnik, Joanna
2016-12-01
Motivation is an important phenomenon in the realm of education, particularly in the university fields connected with physical education and sport, where it is necessary to accommodate and balance intellectual abilities and physical fitness. The present study tested motivation levels among university students in the fields connected with physical education and sport in Poland and Turkey. It was based on the Self-Determination Theory (Deci and Ryan, 1985), namely intrinsic motivation, extrinsic motivation and amotivation which impact human behaviour. The Academic Motivation Scale was used (Vallerand et al., 1992). The aims of the study were twofold, first, to crossculturally validate Polish and Turkish versions of the Academic Motivation Scale and second, to identify and compare the motivation to study depending on nationality and gender. Both Polish and Turkish versions of the questionnaire were validated and converted to a four-factorial structure. The findings indicated that Polish and Turkish students' motivation especially differed in amotivation and intrinsic motivation to know and experience stimulation. Moreover, Turkish female students proved to be at the lowest estimate of amotivation.
Li, Hongyu; Walker, David; Yu, Guoyu; Sayle, Andrew; Messelink, Wilhelmus; Evans, Rob; Beaucamp, Anthony
2013-01-14
Edge mis-figure is regarded as one of the most difficult technical issues for manufacturing the segments of extremely large telescopes, which can dominate key aspects of performance. A novel edge-control technique has been developed, based on 'Precessions' polishing technique and for which accurate and stable edge tool influence functions (TIFs) are crucial. In the first paper in this series [D. Walker Opt. Express 20, 19787-19798 (2012)], multiple parameters were experimentally optimized using an extended set of experiments. The first purpose of this new work is to 'short circuit' this procedure through modeling. This also gives the prospect of optimizing local (as distinct from global) polishing for edge mis-figure, now under separate development. This paper presents a model that can predict edge TIFs based on surface-speed profiles and pressure distributions over the polishing spot at the edge of the part, the latter calculated by finite element analysis and verified by direct force measurement. This paper also presents a hybrid-measurement method for edge TIFs to verify the simulation results. Experimental and simulation results show good agreement.
NASA Astrophysics Data System (ADS)
Zhang, Huifang; Yang, Minghong; Xu, Xueke; Wu, Lunzhe; Yang, Weiguang; Shao, Jianda
2017-10-01
The surface figure control of the conventional annular polishing system is realized ordinarily by the interaction between the conditioner and the lap. The surface profile of the pitch lap corrected by the marble conditioner has been measured and analyzed as a function of kinematics, loading conditions, and polishing time. The surface profile measuring equipment of the large lap based on laser alignment was developed with the accuracy of about 1μm. The conditioning mechanism of the conditioner is simply determined by the kinematics and fully fitting principle, but the unexpected surface profile deviation of the lap emerged frequently due to numerous influencing factors including the geometrical relationship, the pressure distribution at the conditioner/lap interface. Both factors are quantitatively evaluated and described, and have been combined to develop a spatial and temporal model to simulate the surface profile evolution of pitch lap. The simulations are consistent with the experiments. This study is an important step toward deterministic full-aperture annular polishing, providing a beneficial guidance for the surface profile correction of the pitch lap.
The design, construction and testing of the optics for a 147-cm-aperture telescope
NASA Technical Reports Server (NTRS)
Buchroeder, R. A.; Elmore, L. H.; Shack, R. V.; Slater, P. N.
1972-01-01
Geodetic optics research for the Air Force Cambridge Research Laboratories (AFCRL) is described. The work consisted mainly of the fabrication of the optical components for a telescope with a 152-cm-diam (60-in.) primary mirror masked down to 147-cm-diam for use by the AFCRL for a lunar ranging experiment. Among the achievements of this contract were the following: completion of the primary and secondary mirrors for a high-quality 147-cm-diam telescope system in eight months from the start of edging the primary; manufacture and testing of a unique center mount for the primary according to an AFCRL design that allowed for a thin-edged and therefore less-massive mirror; and development of a quantitative analysis of the wire test for calculating the departure of the mirror figure from the design figure quickly and accurately after each polishing step. This analysis method in conjunction with a knowledge of polishing rates for given weights and diameters of tools, mirror, and polishing materials should considerably reduce the polishing time required for future large mirrors.
Long term validation of an accelerated polishing test procedure for HMA pavements.
DOT National Transportation Integrated Search
2013-04-01
The Ohio Department of Transportation (ODOT) has set strategic goals to improve driving safety by maintaining : smooth pavement surfaces with high skid resistance. ODOT has taken the initiative to monitor pavement : friction on Ohio roadways and reme...
Study program to develop and evaluate die and container materials for the growth of silicon ribbons
NASA Technical Reports Server (NTRS)
1978-01-01
Initial sessile drop experiments on SiC, Si3N4 and A1N were conducted. Very promising results were achieved on both SiC and Si3N4 where minimal penetration of these CNTD coatings by molten silicon was observed. More detailed characterization of the CNTD microstructures was accomplished as well as X-ray characterization of the third and fourth candidate materials system sets (i.e. A1N and altered Si3N4). Polished sections of post sessile drop specimens were also prepared and evaluated. The techniques of full scale crucible hot pressing were developed and die grinding development was initiated. The apparatus for measurement of oxygen partial pressure was reconstructed and calibrated. The sessile drop temperature measurement procedure was calibrated for absorption by the pyrex view-port and additional Auger electron analysis was performed at the interface of molten silicon with CNTD Si3N4 and A1N.
Effect of bleaching agent and topical fluoride application on color and gloss of dental ceramics.
Pires-de-Souza, Fernanda de Carvalho Panzeri; Contente, Marta Maria Martins Giamatei; Alandia-Román, Carla Cecilia; Vicente, Sergio Augusto de Freitas; Tonani, Rafaella
2016-01-01
The aim of this study was to evaluate the effect of 16% carbamide peroxide and 1.23% acidulated phosphate fluoride application and their association with a change in color (ΔE*) and brightness of dental ceramic submitted to different finishing procedures. A total of 120 test specimens were fabricated and randomly divided into 3 groups (n = 40) according to the type of finishing: glazing; polishing; or polishing and glazing. Initial color and brightness readouts were taken, and the finished specimens were divided into groups (n = 10) according to the treatment to which they were submitted: fluoride; bleaching; bleaching and fluoride; or control. After this, final color and brightness readouts were taken. The type of polishing had no influence on ΔE* or brightness (P > 0.05). Regardless of which solution was used, a decrease in brightness occurred only for the group treated with bleach and fluoride (P < 0.05). The results showed the use of fluoride after bleaching may interfere with the esthetics of a restoration.
Shafrir, Shai N; Romanofsky, Henry J; Skarlinski, Michael; Wang, Mimi; Miao, Chunlin; Salzman, Sivan; Chartier, Taylor; Mici, Joni; Lambropoulos, John C; Shen, Rui; Yang, Hong; Jacobs, Stephen D
2009-12-10
We report on magnetorheological finishing (MRF) spotting experiments performed on glasses and ceramics using a zirconia-coated carbonyl-iron (CI)-particle-based magnetorheological (MR) fluid. The zirconia-coated magnetic CI particles were prepared via sol-gel synthesis in kilogram quantities. The coating layer was approximately 50-100 nm thick, faceted in surface structure, and well adhered. Coated particles showed long-term stability against aqueous corrosion. "Free" nanocrystalline zirconia polishing abrasives were cogenerated in the coating process, resulting in an abrasive-charged powder for MRF. A viable MR fluid was prepared simply by adding water. Spot polishing tests were performed on a variety of optical glasses and ceramics over a period of nearly three weeks with no signs of MR fluid degradation or corrosion. Stable material removal rates and smooth surfaces inside spots were obtained.
Grazing Incidence Optics Technology
NASA Technical Reports Server (NTRS)
Ramsey, Brian; Smith, W. Scott; Gubarev, Mikhail; McCracken, Jeff
2015-01-01
This project is to demonstrate the capability to directly fabricate lightweight, high-resolution, grazing-incidence x-ray optics using a commercially available robotic polishing machine. Typical x-ray optics production at NASA Marshall Space Flight Center (MSFC) uses a replication process in which metal mirrors are electroformed on to figured and polished mandrels from which they are later removed. The attraction of this process is that multiple copies can be made from a single master. The drawback is that the replication process limits the angular resolution that can be attained. By directly fabricating each shell, errors inherent in the replication process are removed. The principal challenge now becomes how to support the mirror shell during all aspects of fabrication, including the necessary metrology to converge on the required mirror performance specifications. This program makes use of a Zeeko seven-axis computer-controlled polishing machine (see fig. 1) and supporting fabrication, metrology, and test equipment at MSFC. The overall development plan calls for proof-of-concept demonstration with relatively thick mirror shells (5-6 mm, fig. 2) which are straightforward to support and then a transition to much thinner shells (2-3 mm), which are an order of magnitude thinner than those used for Chandra. Both glass and metal substrates are being investigated. Currently, a thick glass shell is being figured. This has enabled experience to be gained with programming and operating the polishing machine without worrying about shell distortions or breakage. It has also allowed time for more complex support mechanisms for figuring/ polishing and metrology to be designed for the more challenging thinner shells. These are now in fabrication. Figure 1: Zeeko polishing machine.
Parma, Radosław; Dąbrowski, Maciej; Ochała, Andrzej; Witkowski, Adam; Dudek, Dariusz; Siudak, Zbigniew; Legutko, Jacek
2017-01-01
Few studies have assessed the development of transcatheter aortic valve implantation (TAVI) in Poland since its introduction in 2008, and data on current TAVI activity or practice are missing. To assess the dynamics of TAVI adoption in Poland and to detect differences among Polish centres in TAVI practice and decision-making. The Polish Interventional Cardiology TAVI Survey (PICTS) was approved by the Polish Association of Cardiovascular Interventions and presented to all 21 national TAVI centres. Between 2008 and 2015 the cumulative number of TAVI performed in Poland was 2189. The annual number of TAVI rose from 8 in 2008 to 670 in 2015 (0.21 to 17.4 implants per million inhabitants, respectively). The median TAVI experience per centre was 80 procedures (95% CI: 38.1-154.6). In 2015 the TAVI penetration rate reached 5.12% of the estimated eligible Polish population. Inoperable and high-risk patients are treated with TAVI in all centres, with 52% of Heart Teams also qualifying medium-risk patients. The rate of transfemoral implantations increased to 83.2% of all procedures in 2015, while transapical implantations decreased to 12%. The frequency of subclavian, direct aortic or transcarotid routes in 2015 was below 3% each. The PICTS survey observed a positive but slow rate of adoption of TAVI in Poland. When compared to Western European countries, our findings highlight a significant treatment gap in high or prohibitive surgical risk patients with severe aortic stenosis. Remarkable variations in TAVI practices among Polish TAVI centres warrant publication of joint national guidelines and recommendations.
Investigation of aluminum gate CMP in a novel alkaline solution
NASA Astrophysics Data System (ADS)
Cuiyue, Feng; Yuling, Liu; Ming, Sun; Wenqian, Zhang; Jin, Zhang; Shuai, Wang
2016-01-01
Beyond 45 nm, due to the superior CMP performance requirements with the metal gate of aluminum in the advanced CMOS process, a novel alkaline slurry for an aluminum gate CMP with poly-amine alkali slurry is investigated. The aluminum gate CMP under alkaline conditions has two steps: stock polishing and fine polishing. A controllable removal rate, the uniformity of aluminum gate and low corrosion are the key challenges for the alkaline polishing slurry of the aluminum gate CMP. This work utilizes the complexation-soluble function of FA/O II and the preference adsorption mechanism of FA/O I nonionic surfactant to improve the uniformity of the surface chemistry function with the electrochemical corrosion research, such as OCP-TIME curves, Tafel curves and AC impedance. The result is that the stock polishing slurry (with SiO2 abrasive) contains 1 wt.% H2O2,0.5 wt.% FA/O II and 1.0 wt.% FA/O I nonionic surfactant. For a fine polishing process, 1.5 wt.% H2O2, 0.4 wt.% FA/O II and 2.0 wt.% FA/O I nonionic surfactant are added. The polishing experiments show that the removal rates are 3000 ± 50 Å/min and 1600 ± 60 Å/min, respectively. The surface roughnesses are 2.05 ± 0.128 nm and 1.59 ± 0.081 nm, respectively. A combination of the functions of FA/O II and FA/O I nonionic surfactant obtains a controllable removal rate and a better surface roughness in alkaline solution.
Schmitter, M; Lotze, G; Bömicke, W; Rues, S
2015-12-01
The purpose of this study was to assess the effect of surface treatment on the fracture resistance of zirconia-based all-ceramic anterior crowns. Sixty-four zirconia-based all-ceramic anterior crowns, veneered by use of a press-on technique, were produced. For 48 crowns intraoral adjustment was simulated (A-group), 16 crowns remained unadjusted (WA-group). The adjusted area was then treated in three ways: 1. no further surface treatment; 2. polishing, with irrigation, using polishers interspersed with diamond grit for ceramics; and 3. polishing and glaze firing. Half of the specimens were loaded until fracture in an universal testing device without artificial ageing; the other crowns underwent thermocycling and chewing simulation before ultimate-load testing. Explorative statistical analysis was performed by use of non-parametric and parametric tests. In addition, fracture-strength tests according to ISO 6872 were performed for veneer ceramic subjected to the different surface treatments. Finite element analysis was also conducted for the crowns, and surface roughness was measured. Crowns in the A-group were more sensitive to aging than crowns in the WA-group (p=0.038). Although both polishing and glaze firing slightly improved the fracture resistance of the specimens, the fracture resistance in the WA-group (initial fracture resistance (IFR): 652.0 ± 107.7N, remaining fracture resistance after aging (RFR): 560.6 ± 233.3N) was higher than the fracture resistance in the A-group (polished: IFR: 477.9 ± 108.8N, RFR: 386.0 ± 218.5N; glaze firing: IFR: 535.5 ± 128.0N, RFR: 388.6 ± 202.2N). Surface roughness without adjustment was Ra=0.1 μm; for adjustment but without further treatment it was Ra=1.4 μm; for adjustment and polishing it was Ra=0.3 μm; and for adjustment, polishing, and glazing it was Ra=0.6 μm. Stress distributions obtained by finite element analysis in combination with fracture strength tests showed that fractures most probably originated from the occlusal surface. To improve fracture resistance and reduce the incidence of failure, extensive occlusal adjustment of veneered anterior zirconia restorations should be avoided. Neither polishing nor glazing could restore the fracture resistance to the level maintained with unadjusted crowns. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Pinto, Gustavo Da Col dos Santos; Dias, Kleber Campioni; Cruvinel, Diogo Rodrigues; Garcia, Lucas da Fonseca Roberti; Consani, Simonides; Pires-De-Souza, Fernanda de Carvalho Panzeri
2013-01-01
To assess the influence of finishing/polishing procedure on color stability (ΔE ) and surface roughness (R(a)) of composites (Heliomolar and Tetric - color A2) submitted to accelerated artificial aging (AAA). Sixty test specimens were made of each composite (12 mm × 2 mm) and separated into six groups (n = 10), according to the type of finishing/polishing to which they were submitted: C, control; F, tip 3195 F; FF, tip 3195 FF; FP, tip 3195 F + diamond paste; FFP, tip 3195 FF + diamond paste; SF, Sof-Lex discs. After polishing, controlled by an electromechanical system, initial color (spectrophotometer PCB 6807 BYK GARDNER) and R(a) (roughness meter Surfcorder SE 1700, cut-off 0.25 mm) readings were taken. Next, the test specimens were submitted to the AAA procedure (C-UV Comexim) for 384 hours, and at the end of this period, new color readings and R(a) were taken. Statistical analysis [2-way analysis of variance (ANOVA), Bonferroni, P < 0.05] showed that all composites demonstrated ΔE alteration above the clinically acceptable limits, with the exception of Heliomolar composite in FP. The greatest ΔE alteration occurred for Tetric composite in SF (13.38 ± 2.10) statistically different from F and FF (P < 0.05). For R(a), Group F showed rougher samples than FF with statistically significant difference (P < 0.05). In spite of the surface differences, the different finishing/polishing procedures were not capable of providing color stability within the clinically acceptable limits.
NASA Astrophysics Data System (ADS)
Menezes, Pradeep L.; Kishore; Kailas, Satish V.; Lovell, Michael R.
2015-01-01
Surface texture influences friction during sliding contact conditions. In the present investigation, the effect of surface texture and roughness of softer and harder counter materials on friction during sliding was analyzed using an inclined scratch testing system. In the experiments, two test configurations, namely (a) steel balls against aluminum alloy flats of different surface textures and (b) aluminum alloy pins against steel flats of different surface textures, are utilized. The surface textures were classified into unidirectionally ground, 8-ground, and randomly polished. For a given texture, the roughness of the flat surfaces was varied using grinding or polishing methods. Optical profilometer and scanning electron microscope were used to characterize the contact surfaces before and after the experiments. Experimental results showed that the surface textures of both harder and softer materials are important in controlling the frictional behavior. The softer material surface textures showed larger variations in friction between ground and polished surfaces. However, the harder material surface textures demonstrated a better control over friction among the ground surfaces. Although the effect of roughness on friction was less significant when compared to textures, the harder material roughness showed better correlations when compared to the softer material roughness.
NASA Astrophysics Data System (ADS)
Arkhipov, Iu. V.; Belashkov, I. N.; Datskevich, N. P.; Egorov, V. N.; Iziumov, A. F.
1986-01-01
Threshold conditions for the formation of a plasma due to optical breakdown of air on the polished surfaces of Al, Co, Mi, and W samples have been investigated experimentally. The optical breakdown was initiated by pulsed radiation from two CO2 lasers having pulse powers 0.5 and 1.0 kJ, respectively. The thresholds for the formation of the plasma were determined for two exposure spots of o/14 sq mm and 46 sq cm, respectively. A metallographic study was carried out in order to identify the specific types of defects corresponding to the lowest optical breakdown thresholds. Before-and-after photographs of the metal surfaces are provided.
Light Weight Silicon Mirrors for Space Instrumentation
NASA Technical Reports Server (NTRS)
Bly, Vincent T.; Hill, Peter C.; Hagopian, John G.; Strojay, Carl R.; Miller, Timothy
2012-01-01
Each mirror is a monolithic structure from a single crystal of silicon. The mirrors are light weighted after the optical surface is ground and polished. Mirrors made during the initial phase of this work were typically 1/50 lambda or better (RMS at 633 n m)
[Death cause of Józef Hempel, M.D. - truth or myth?].
Witczak, Włodzimierz
2004-01-01
In this article the author makes an attempt to explain causes of untimely death of Józef Hempel, a Cracow physician. In the Polish historiography there has been a strong belief that he was a victim of an unfortunate experiment with tuberculin administered to him by Robert Koch in Berlin in 1890. However, there was every indication that his death was caused by purulent appendicitis with complicated peritonitis. Memoirs of Stefan Dunin, a journalist, were the most probable source of this misinformation on the tuberculin experiment. The author emphasizes that hte memoirs should not be used in works on history of the Polish phthisiology. He draws our attention to dangers that were related to attempts of treating tuberculosis with tuberculin and also gives basic biographical information about Hempel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suratwala, Tayyab
2016-09-22
In the follow study, we have developed a detailed understanding of the chemical and mechanical microscopic interactions that occur during polishing affecting the resulting surface microroughness of the workpiece. Through targeted experiments and modeling, the quantitative relationships of many important polishing parameters & characteristics affecting surface microroughness have been determined. These behaviors and phenomena have been described by a number of models including: (a) the Ensemble Hertzian Multi Gap (EHMG) model used to predict the removal rate and roughness at atomic force microscope (AFM) scale lengths as a function of various polishing parameters, (b) the Island Distribution Gap (IDG) modelmore » used to predict the roughness at larger scale lengths, (c) the Deraguin-Verwey-Landau-Overbeek (DLVO) 3-body electrostatic colloidal model used to predict the interaction of slurry particles at the interface and roughness behavior as a function of pH, and (d) a diffusion/chemical reaction rate model of the incorporation of impurities species into the polishing surface layer (called the Bielby layer). Based on this improved understanding, novel strategies to polish the workpiece have been developed simultaneously leading to both ultrasmooth surfaces and high material removal rates. Some of these strategies include: (a) use of narrow PSD slurries, (b) a novel diamond conditioning recipe of the lap to increase the active contact area between the workpiece and lap without destroying its surface figure, (c) proper control of pH for a given glass type to allow for a uniform distribution of slurry particles at the interface, and (d) increase in applied load just up to the transition between molecular to plastic removal regime for a single slurry particle. These techniques have been incorporated into a previously developed finishing process called Convergent Polishing leading to not just economical finishing process with improved surface figure control, but also simultaneously leading to low roughness surface with high removal rates.« less
McCombs, Gayle; Russell, Daniel M
2014-12-01
Dental professionals suffer from a high prevalence of work-related musculoskeletal disorders (MSD). Dental hygienists in particular have a high prevalence of pain in the forearms and hands. The objective of this study was to compare 1 cordless handpiece to 2 corded handpieces during simulated tooth polishing in terms of the muscle loads (recorded as electromyography (EMG) activity), duration of polishing procedure, and dental hygienist opinion about ease of use. EMG was used to quantify muscle electrical activity of 4 forearm muscles during simulated dental polishing with 2 corded handpieces (HP-A and HP-B) and 1 cordless handpiece (HP-C). A convenience sample of 30 dental hygienists (23 to 57 years of age) with 1 to 20+ years of clinical practice experience completed the study. Each participant spent approximately 5 minutes polishing 3 predetermined teeth in each of the 4 quadrants. The sequence of the handpieces was randomly assigned. At the end of the study, participants completed a subjective end user evaluation of handpiece preference. Muscle activity levels of 10th, 50th and 90th percentiles did not differ significantly between the 3 handpieces tested (p>0.05). However, total muscle workload (integrated EMG) was lowest for the cordless handpiece (HP-C), but this was only significantly less than HP-A (p<0.05). Polishing using the cordless handpiece (HP-C) (M=257 seconds, SD=112 seconds) took significantly less time than either the HP-A corded (M=290 seconds, SD=137 seconds) or HP-B corded handpiece (M=290 seconds, SD=126 seconds) (p<0.05). Overall, 50% of the study participants preferred the cordless handpiece, 37% preferred HP-A and 13% preferred HP-B (p<0.05). Use of the cordless handpiece reduced the duration of polishing, which in turn led to less total muscle activity, but not muscle intensity. Overall, dental hygienists preferred the cordless handpiece. Copyright © 2014 The American Dental Hygienists’ Association.
Polishing of municipal secondary effluent using native microalgae consortia.
Beltrán-Rocha, Julio César; Barceló-Quintal, Icela Dagmar; García-Martínez, Magdalena; Osornio-Berthet, Luis; Saavedra-Villarreal, Nidia; Villarreal-Chiu, Juan; López-Chuken, Ulrico Javier
2017-04-01
This work evaluates the use of native microalgae consortia for a dual role: polishing treatment of municipal wastewater effluents and microalgae biomass feedstock potential for biodiesel or biofertilizer production. An initial screening was undertaken to test N and P removal from secondary effluents and biomass production by 12 consortia. A subsequent treatment was performed by selected consortia (01 and 12) under three operational conditions: stirring (S), S + 12 h of daily aeration (S + A) and S + A enriched with CO 2 (S + AC). All treatments resulted in compliance with environmental regulations (e.g. Directive 91/271/EEC) and high removal efficiency of nutrients: 64-79% and 80-94% of total N and PO 4 3- -P respectively. During the experiments it was shown that pH alkalinization due to microalgae growth benefits the chemical removal of ammonia and phosphorus. Moreover, advantages of pH increase could be accomplished by intermittent CO 2 addition which in this research (treatment S + AC) promoted higher yield and lipid concentration. The resulting dry biomass analysis showed a low lipid content (0.5-4.3%) not ideal for biodiesel production. Moreover, the high rate of ash (29.3-53.0%) suggests that biomass could be readily recycled as a biofertilizer due to mineral supply and organic constituents formed by C, N and P (e.g. carbohydrate, protein, and lipids).
Król, Joanna; Szcześniak, Małgorzata; Koziarska, Dorota; Rzepa, Teresa
2015-01-01
The aim of the study was to determine temporal orientation in patients diagnosed with RR-MS as compared with that of healthy individuals; to analyse self-evaluated acceptance levels in terms of physical and psychological condition and self-reliance; an attempt to identify factors of illness acceptance in patients with RR-MS including temporal perspective. Acceptance of Illness Scale (AIS, adapted into Polish by Z. Juczyński), Zimbardo Time Perspective Inventory (ZTPI, adapted into Polish by M. Mażewski), and original interview aimed to assess socio-demographic data and self-evaluated physical as well as psychological condition and self-reliance of patients with MS (referred to the neurological testing according to the EDSS). Patients with RR-MS focus on fatalistic and hedonistic present more than healthy individuals. They also tend to reflect on their negative past experience. Acceptance of illness correlated positively with subjective assessment of physical and psychological condition as well as self-reliance, and negatively with objective disability score (measured with the use of EDSS) and a factor considering time of disease duration. Avoiding contemplation of negative past and concentrating on hedonistic future constitute significant predictors of illness acceptance. These results may be of importance in terms of holistic approach to treatment of RR-MS patients. In the initial stage of the disease progression, patients might benefit from psychological support due to change in temporal orientation.
The C-stem in clinical practice: fifteen-year follow-up of a triple tapered polished cemented stem.
Purbach, Bodo; Kay, Peter R; Siney, Paul D; Fleming, Patricia A; Wroblewski, B Michael
2013-09-01
The triple tapered polished cemented stem, C-Stem, introduced in 1993 was based on the original Charnley concept of the "flat back" polished stem. We present our continuing experience with the C-Stem in 621 consecutive primary arthroplasties implanted into 575 patients between 1993 and 1997. Four hundred and eighteen arthroplasties had a clinical and radiological follow-up past 10 years with a mean follow-up of 13 years (10-15). There were no revisions for stem loosening but 2 stems were revised for fracture - both with a defective cement mantle proximally. The stem design and the surgical technique support the original Charnley concept of limited stem subsidence within the cement mantle and the encouraging results continue to stand as a credit to Sir John Charnley's original philosophy. Copyright © 2013 Elsevier Inc. All rights reserved.
LP01 to LP11 mode convertor based on side-polished small-core single-mode fiber
NASA Astrophysics Data System (ADS)
Liu, Yan; Li, Yang; Li, Wei-dong
2018-03-01
An all-fiber LP01-LP11 mode convertor based on side-polished small-core single-mode fibers (SMFs) is numerically demonstrated. The linearly polarized incident beam in one arm experiences π shift through a fiber half waveplate, and the side-polished parts merge into an equivalent twin-core fiber (TCF) which spatially shapes the incident LP01 modes to the LP11 mode supported by the step-index few-mode fiber (FMF). Optimum conditions for the highest conversion efficiency are investigated using the beam propagation method (BPM) with an approximate efficiency as high as 96.7%. The proposed scheme can operate within a wide wavelength range from 1.3 μm to1.7 μm with overall conversion efficiency greater than 95%. The effective mode area and coupling loss are also characterized in detail by finite element method (FEM).
Effects of the gap slope on the distribution of removal rate in Belt-MRF.
Wang, Dekang; Hu, Haixiang; Li, Longxiang; Bai, Yang; Luo, Xiao; Xue, Donglin; Zhang, Xuejun
2017-10-30
Belt magnetorheological finishing (Belt-MRF) is a promising tool for large-optics processing. However, before using a spot, its shape should be designed and controlled by the polishing gap. Previous research revealed a remarkably nonlinear relationship between the removal function and normal pressure distribution. The pressure is nonlinearly related to the gap geometry, precluding prediction of the removal function given the polishing gap. Here, we used the concepts of gap slope and virtual ribbon to develop a model of removal profiles in Belt-MRF. Between the belt and the workpiece in the main polishing area, a gap which changes linearly along the flow direction was created using a flat-bottom magnet box. The pressure distribution and removal function were calculated. Simulations were consistent with experiments. Different removal functions, consistent with theoretical calculations, were obtained by adjusting the gap slope. This approach allows to predict removal functions in Belt-MRF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shafrir, Shai N.; Romanofsky, Henry J.; Skarlinski, Michael
2009-12-10
We report on magnetorheological finishing (MRF) spotting experiments performed on glasses and ceramics using a zirconia-coated carbonyl-iron (CI)-particle-based magnetorheological (MR) fluid. The zirconia-coated magnetic CI particles were prepared via sol-gel synthesis in kilogram quantities. The coating layer was {approx}50-100 nm thick, faceted in surface structure, and well adhered. Coated particles showed long-term stability against aqueous corrosion. ''Free'' nanocrystalline zirconia polishing abrasives were cogenerated in the coating process, resulting in an abrasive-charged powder for MRF. A viable MR fluid was prepared simply by adding water. Spot polishing tests were performed on a variety of optical glasses and ceramics over a periodmore » of nearly three weeks with no signs of MR fluid degradation or corrosion. Stable material removal rates and smooth surfaces inside spots were obtained.« less
Polish Geophysical Solid Earth Infrastructure Contributing to EPOS
NASA Astrophysics Data System (ADS)
Debski, W.; Mutke, G.; Suchcicki, J.; Jozwiak, W.; Wiejacz, P.; Trojanowski, J.
2012-04-01
In this poster we present the current state of the main polish solid-earth-orientated infrastructures and shortly described history of their development, current state, and some plans for their future development. The presen- tation concentrates only on the classical infrastructure leaving aside for the while the the geodetic-orientated infrastructure, like GPS network and the GPS processing data centers, gravimetric infrastructure and others of this type. Polish broadband seismic infrastructure consists of 7 permanent broadband stations incorporated into the VEBSN initiative running at the polish territory and one operated in collaboration with NORSAR is settled at the Hornsund (Svalbard) polish polar station. All stations are equipped with STS-2 seismometers and polish MK-6 seismic stations providing 120 dB dynamics 100Hz sampling and data transmission in a real time to processing center. Besides this permanent broadband seismic network (PLSN) the Central Institute of Mining is running the permanent regional, short period network at the Upper Silesia area dedicated to the detailed monitoring of seismicity induced by the black coal mining activity in this area. The network consists of As the mining activity is the main source of seismicity in Poland also all mines are running underground short period networks, like for example Rudna-Polkowice copper mine seismic network consisting of 64 underground located short period seimometers. In that area, especially around the Zelazny Most: the huge post-floating artificial lake the, IGF PAS is running the local seismic array consisting of 4 short period seismometers. Besides these permanent network IGF PAN is running the portable seismic network for detailed mapping a possible natural seismic activity in selected regions of Poland. Important contribution to classical geophysical observation in the electro-magnetic field are provided by three permanent geomagnetic observatories (one at Hornsund) and supporting set of 10 portable, high-accuracy magnetoteluric stations.
Narożna, Dorota; Pudełko, Krzysztof; Króliczak, Joanna; Golińska, Barbara; Sugawara, Masayuki; Mądrzak, Cezary J.
2015-01-01
It was previously demonstrated that there are no indigenous strains of Bradyrhizobium japonicum forming nitrogen-fixing root nodule symbioses with soybean plants in arable field soils in Poland. However, bacteria currently classified within this species are present (together with Bradyrhizobium canariense) as indigenous populations of strains specific for nodulation of legumes in the Genisteae tribe. These rhizobia, infecting legumes such as lupins, are well established in Polish soils. The studies described here were based on soybean nodulation field experiments, established at the Poznań University of Life Sciences Experiment Station in Gorzyń, Poland, and initiated in the spring of 1994. Long-term research was then conducted in order to study the relation between B. japonicum USDA 110 and USDA 123, introduced together into the same location, where no soybean rhizobia were earlier detected, and nodulation and competitive success were followed over time. Here we report the extra-long-term saprophytic survival of B. japonicum strains nodulating soybeans that were introduced as inoculants 20 years earlier and where soybeans were not grown for the next 17 years. The strains remained viable and symbiotically competent, and molecular and immunochemical methods showed that the strains were undistinguishable from the original inoculum strains USDA 110 and USDA 123. We also show that the strains had balanced numbers and their mobility in soil was low. To our knowledge, this is the first report showing the extra-long-term persistence of soybean-nodulating strains introduced into Polish soils and the first analyzing the long-term competitive relations of USDA 110 and USDA 123 after the two strains, neither of which was native, were introduced into the environment almost 2 decades ago. PMID:26048934
Narożna, Dorota; Pudełko, Krzysztof; Króliczak, Joanna; Golińska, Barbara; Sugawara, Masayuki; Mądrzak, Cezary J; Sadowsky, Michael J
2015-08-15
It was previously demonstrated that there are no indigenous strains of Bradyrhizobium japonicum forming nitrogen-fixing root nodule symbioses with soybean plants in arable field soils in Poland. However, bacteria currently classified within this species are present (together with Bradyrhizobium canariense) as indigenous populations of strains specific for nodulation of legumes in the Genisteae tribe. These rhizobia, infecting legumes such as lupins, are well established in Polish soils. The studies described here were based on soybean nodulation field experiments, established at the Poznań University of Life Sciences Experiment Station in Gorzyń, Poland, and initiated in the spring of 1994. Long-term research was then conducted in order to study the relation between B. japonicum USDA 110 and USDA 123, introduced together into the same location, where no soybean rhizobia were earlier detected, and nodulation and competitive success were followed over time. Here we report the extra-long-term saprophytic survival of B. japonicum strains nodulating soybeans that were introduced as inoculants 20 years earlier and where soybeans were not grown for the next 17 years. The strains remained viable and symbiotically competent, and molecular and immunochemical methods showed that the strains were undistinguishable from the original inoculum strains USDA 110 and USDA 123. We also show that the strains had balanced numbers and their mobility in soil was low. To our knowledge, this is the first report showing the extra-long-term persistence of soybean-nodulating strains introduced into Polish soils and the first analyzing the long-term competitive relations of USDA 110 and USDA 123 after the two strains, neither of which was native, were introduced into the environment almost 2 decades ago. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Hensawang, Supanad; Chanpiwat, Penradee
2018-09-01
Food is one of the major sources of arsenic (As) exposure in humans. The objectives of this study were to determine the bioaccessible concentration of As in rice grain sold in Bangkok and to evaluate the potential health risks associated with rice consumption. Polished (n = 32) and husked (n = 17) jasmine rice were collected from local markets. In vitro digestion was performed to determine the bioaccessible As concentrations, which were used for probabilistic health risk assessments in different age groups of the population. Approximately 43.0% and 44.4% of the total As in the grain of polished and husked rice, respectively, was in the form of bioaccessible As. Significantly higher bioaccessible As concentrations were found in husked rice than in polished rice (1.5-3.8 times greater). The concentrations of bioaccessible As in polished and husked rice were lower than the Codex standard for As in rice. The average daily dose of As via rice consumption is equivalent to the daily ingestion of 2 L of water containing approximately 3.2-7.2 μg L -1 of As. Approximately 0.2%-13.7% and 10.7%-55.3% of the population may experience non-carcinogenic effects from polished and husked rice consumption, respectively. Approximately 1%-11.6% of children and 74.1%-99.8% of adults were at risk of cancer. The maximum cancer probabilities were 3 children and 6 adults in 10,000 individuals. The probabilistic risk results indicated that children and adults were at risk of both non-carcinogenic and carcinogenic effects from both types of rice consumption. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Chen, Hua; Chen, Jihong; Wang, Baorui; Zheng, Yongcheng
2016-10-01
The Magnetorheological finishing (MRF) process, based on the dwell time method with the constant normal spacing for flexible polishing, would bring out the normal contour error in the fine polishing complex surface such as aspheric surface. The normal contour error would change the ribbon's shape and removal characteristics of consistency for MRF. Based on continuously scanning the normal spacing between the workpiece and the finder by the laser range finder, the novel method was put forward to measure the normal contour errors while polishing complex surface on the machining track. The normal contour errors was measured dynamically, by which the workpiece's clamping precision, multi-axis machining NC program and the dynamic performance of the MRF machine were achieved for the verification and security check of the MRF process. The unit for measuring the normal contour errors of complex surface on-machine was designed. Based on the measurement unit's results as feedback to adjust the parameters of the feed forward control and the multi-axis machining, the optimized servo control method was presented to compensate the normal contour errors. The experiment for polishing 180mm × 180mm aspherical workpiece of fused silica by MRF was set up to validate the method. The results show that the normal contour error was controlled in less than 10um. And the PV value of the polished surface accuracy was improved from 0.95λ to 0.09λ under the conditions of the same process parameters. The technology in the paper has been being applied in the PKC600-Q1 MRF machine developed by the China Academe of Engineering Physics for engineering application since 2014. It is being used in the national huge optical engineering for processing the ultra-precision optical parts.
Lee, Sung Jung; Park, Hyeong Jin; Kim, Wooseong; Jin, Jong Sung; Abd El-Aty, A M; Shim, Jae-Han; Shin, Sung Chul
2009-04-01
Liquid chromatography in conjunction with tandem mass spectrometry was used to directly quantify of 47 pesticide residues from cooked wheat flour and polished rice, which are the most widely consumed cereals in the Republic of Korea. The sample clean-up was carried out according to the method established by the Korea Food and Drug Administration. The mobile phase for liquid chromatography separation consisted of water and 5 mm methanolic ammonium formate. Tandem mass spectroscopy experiments were performed in electrospray ionization positive mode and the multiple reaction monitoring mode. The matrix effects estimated for the 47 pesticides had a mean value of 99% and ranged from 45 to 147%. High recoveries (70-140%) and relative standard deviations (< or = 20%) were achieved for most of the pesticides tested. The method used in this study allowed for rapid quantification and identification of low levels of pesticides in cooked wheat flour and polished rice samples. Of the screened pesticide residues, only tricyclazole and fenobucarb were found in polished rice samples. However, no samples contained residues above the MRL established by the Korea Food and Drug Administration.
Knowledge of chronic total occlusion among Polish interventional cardiologists.
Bryniarski, Krzysztof L; Zabojszcz, Michał; Dębski, Grzegorz; Marchewka, Jakub; Legutko, Jacek; Surowiec, Sławomir; Siudak, Zbigniew; Żmudka, Krzysztof; Dudek, Dariusz; Bryniarski, Leszek
2015-01-01
Chronic total occlusion (CTO) recanalization is indicated in patients with symptoms and evidence of ischemia, but in most cases those types of lesions are still treated medically. In the last few years CTO angioplasty technique has changed dramatically due to considerable advances in techniques and dedicated equipment. An attempt to assess the state of knowledge of technical aspects of CTO angioplasty of coronary arteries among Polish interventional cardiologists. Questionnaire survey performed during two major Polish invasive cardiology workshops. In the study there participated 113 physicians with an average length of work experience of 13 years, most of them cardiologists certified as independent primary operators. The majority of respondents recognized the need of prevention of thrombotic complications through control of activated coagulation time during the CTO procedures. Prevention of renal complications and X-ray protection are also recognized as a significant part of the procedures. The benefits from the use of over-the-wire microcatheters and balloons, the proper choice of dedicated guidewires, contralateral injections and retrograde technique are underestimated. Despite satisfactory knowledge about indications and qualification for the CTO procedure, the awareness of procedural aspects (particularly the retrograde technique) as well as the dedicated CTO equipment among Polish interventional cardiologists is still insufficient.
Automated Boiler Combustion Controls for Emission Reduction and Efficiency Improvement
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
1998-12-02
In the late 1980s, then President Bush visited Krakow, Poland. The terrible air quality theremotivated him to initiate a USAID-funded program, managed by DOE, entitled "Krakow Clean Fossil Fuels and Energy Efficiency Program." The primary objective of this program was to encourage the formation of commercial ventures between U.S. and Polish firms to provide equipment and/or services to reduce pollution from low-emission sources in Krakow, Poland. This program led to the award of a number of cooperative agreements, including one to Control Techtronics International. The technical objective of CTI's cooperative agreement is to apply combustion controls to existing boiler plantsmore » in Krakow and transfer knowledge and technology through a joint U.S. and Polish commercial venture. CTI installed automatic combustion controls on five coal boilers for the district heating system in Krakow. Three of these were for domestic hot-water boilers, and two were for steam for industrial boilers. The following results have occurred due to the addition of CTI's combustion controls on these five existing boilers: ! 25% energy savings ! 85% reduction in particulate emissions The joint venture company CTI-Polska was then established. Eleven additional technical and costing proposals were initiated to upgrade other coal boilers in Krakow. To date, no co-financing has been made available on the Polish side. CTI-Polska continues in operation, serving customers in Russia and Ukraine. Should the market in Poland materialize, the joint venture company is established there to provide equipment and service.« less
McLucas, E; Moran, M T; Rochev, Y; Carroll, W M; Smith, T J
2006-01-01
The surface properties of vascular devices dictate the initial postimplantation reactions that occur and thus the efficacy of the implantation procedure. Over the last number of years, a number of different stent designs have emerged and stents are generally polished to a mirror finish during the manufacturing procedure. This study sought to investigate the effect of stainless steel surface roughness on endothelial cell gene expression using an appropriate cell culture in vitro assay system. Stainless steel discs were roughened by shot blasting or polished by mechanical polishing. The surface roughness of the treated and untreated discs was determined by atomic force microscopy (AFM). Cells were seeded on collagen type 1 gels and left to attach for 24 h. Stainless steel discs of varying roughness were then placed in contact with the cells and incubated for 24 h. RNA extractions and quantitative real-time reverse transcriptase-polymerase chain reaction (RT-PCR) was then performed to determine the expression levels of candidate genes in the treated cells compared to suitable control cells. E-selectin and vascular cellular adhesion molecule (VCAM-1) were found to be significantly up-regulated in cells incubated with polished and roughened samples, indicating endothelial cell activation and inflammation. This study indicates that the surface roughness of stainless steel is an important surface property in the development of vascular stents.
[Jan Pilecki (1821-1878) and achievements his Druskieninkai].
Kierzek, Andrzej; Kuciel-Lewandowska, Jadwiga; Pozowski, Andrzej; Borowicz-Paprocka, Małgorzata
2012-01-01
The history of development of health resort Druskieniki basing on Adam Wrzosek, an eminent Polish historian of medicine pointed out. The beauty and advantages of this health resort is depicted widely. The living and professional achievements of Jan Pilecki (1821-1878), an eminent physician of health resort, his significance for development and of Druskieninkai are presented in more detail. The medical indications and contraindications in Druskieniki basing on his own experiences have been reported. Pilecki was a author of many medical publications in Polish medical magazines. His papers contained interested medical observations and description of social life and entertainments in this health resort.
Note: Automated electrochemical etching and polishing of silver scanning tunneling microscope tips.
Sasaki, Stephen S; Perdue, Shawn M; Rodriguez Perez, Alejandro; Tallarida, Nicholas; Majors, Julia H; Apkarian, V Ara; Lee, Joonhee
2013-09-01
Fabrication of sharp and smooth Ag tips is crucial in optical scanning probe microscope experiments. To ensure reproducible tip profiles, the polishing process is fully automated using a closed-loop laminar flow system to deliver the electrolytic solution to moving electrodes mounted on a motorized translational stage. The repetitive translational motion is controlled precisely on the μm scale with a stepper motor and screw-thread mechanism. The automated setup allows reproducible control over the tip profile and improves smoothness and sharpness of tips (radius 27 ± 18 nm), as measured by ultrafast field emission.
Du, Hang; Song, Ci; Li, Shengyi; Xu, Mingjin; Peng, Xiaoqiang
2017-05-20
In the process of computer controlled optical surfacing (CCOS), the uncontrollable rolled edge restricts further improvements of the machining accuracy and efficiency. Two reasons are responsible for the rolled edge problem during small tool polishing. One is that the edge areas cannot be processed because of the orbit movement. The other is that changing the tool influence function (TIF) is difficult to compensate for in algorithms, since pressure step appears in the local pressure distribution at the surface edge. In this paper, an acentric tool influence function (A-TIF) is designed to remove the rolled edge after CCOS polishing. The model of A-TIF is analyzed theoretically, and a control point translation dwell time algorithm is used to verify that the full aperture of the workpiece can be covered by the peak removal point of the tool influence functions. Thus, surface residual error in the full aperture can be effectively corrected. Finally, the experiments are carried out. Two fused silica glass samples of 100 mm×100 mm are polished by traditional CCOS and the A-TIF method, respectively. The rolled edge was clearly produced in the sample polished by the traditional CCOS, while residual errors do not show this problem the sample polished by the A-TIF method. Therefore, the rolled edge caused by the traditional CCOS process is successfully suppressed during the A-TIF process. The ability to suppress the rolled edge of the designed A-TIF has been confirmed.
Material removal and surface figure during pad polishing of fused silica
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suratwala, T I; Feit, M D; Steele, W A
2009-05-04
The material removal and surface figure after ceria pad polishing of fused silica glass have been measured and analyzed as a function of kinematics, loading conditions, and polishing time. Also, the friction at the workpiece/lap interface, the slope of the workpiece relative to the lap plane, and lap viscoelastic properties have been measured and correlated to material removal. The results show that the relative velocity between the workpiece & lap (determined by the kinematics) and the pressure distribution determine the spatial and temporal material removal and hence the final surface figure of the workpiece. In the case where the appliedmore » loading and relative velocity distribution over the workpiece are spatially uniform, a significant non-uniform spatial material removal from the workpiece surface is observed. This is due to a non-uniform pressure distribution resulting from: (1) a moment caused by a pivot point and interface friction forces; (2) viscoelastic relaxation of the polyurethane lap; and (3) a physical workpiece/lap interface mismatch. Both the kinematics and these contributions to the pressure distribution are quantitatively described, and then combined to form a spatial and temporal Preston model & code for material removal (called Surface Figure or SurF{copyright}). The surface figure simulations are consistent with the experiment for a wide variety of polishing conditions. This study is an important step towards deterministic full-aperture polishing, which would allow optical glass fabrication to be performed in a more repeatable, less iterative, and hence more economical manner.« less
Amoco unit acquires two blocks covering 2. 7 million acres in Poland
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-10-12
This paper reports that an Amoco Production Co. unit has signed the first agreement by a western company for conventional petroleum exploration rights in Poland. The agreement between Amoco Poland Ltd. and Poland's Ministry of Environmental Protection, Natural Resources, and Forestry calls for Amoco to make an initial $20 million investment to conduct seismic surveys and drill wildcats on two blocks. Block A is a 1,695,750 acre spread southwest of Warsaw in the heart of the Polish trough. Block B covers about 979,000 acres southeast of Lublin on the Polish-Ukrainian border. The state has an option to acquire as muchmore » as 30% interest in future hydrocarbon development.« less
NDE of PWA 1480 single crystal turbine blade material
NASA Technical Reports Server (NTRS)
Klima, Stanley J.; Orange, Thomas W.; Dreshfield, Robert L.
1993-01-01
Cantilever bending fatigue specimens were examined by fluorescent liquid penetrant and radioactive gas penetrant (Krypton) non-destructive evaluation (NDE) methods and tested. Specimens with cast, ground, or polished surface were evaluated to study the effect of surface condition on NDE and fatigue crack initiation. Fractographic and metallurgical analyses were performed to determine the nature of crack precursors. Preliminary results show that fatigue strength was lower for specimens with cast surfaces than for specimens with machined surfaces. The liquid penetrant and gas penetrant techniques both provided indications of a large population of defects on the cast surfaces. On ground or polished specimen surfaces, the gas penetrant appeared to estimate the actual number of voids more accurately than the liquid penetrant.
The beginnings of modern research on propolis in poland.
Kuropatnicki, Andrzej K; Szliszka, Ewelina; Kłósek, Małgorzata; Król, Wojciech
2013-01-01
Propolis studies in Poland were initiated by Professor Stan Scheller in the 1960s. It was a team of Polish researchers who developed a method of introducing hydrophobic ethanol extracts of propolis (EEP) into aqueous solutions, which enabled the study of their biological properties. The studies performed in Poland showed that EEP possesses antioxidant, radioprotective, and immunostimulating properties. It was possible to demonstrate antibacterial activity of propolis on Gram-positive bacteria, virulent Mycobacterium tuberculosis, and protozoa as well as stimulating activity of aqueous extracts of propolis on proliferation of cells in vitro. Polish investigators showed that propolis stimulates regeneration of tissue, acts as antioxidant and radioprotector, has strong immunostimulative properties, affects animals' life span by extending it, and improves intellectual and life functions of the elderly.
Degradation rates of alachlor, atrazine and bentazone in the profiles of Polish Luvisols
NASA Astrophysics Data System (ADS)
Paszko, Tadeusz; Muszyński, Paweł
2017-07-01
The degradation rates of three herbicides (alachlor, atrazine, and bentazone) were examined according to OECD Guideline 307 in three profiles of grey-brown podzolic soil (Luvisol) in a laboratory experiment. The aim of the experiment was to determine herbicide degradation parameters and their relationships with soil properties. Degradation processes were effectively described by a first-order model. However, in some cases, the best results were produced by bi-phasic kinetics (hockey-stick and bi-exponential model). The degradation rates of the tested herbicides at 25°C and 40% maximum water holding capacity, established based on half-life values in the Ap horizon, increased in the following order: atrazine (32.6-42.8 days) < bentazone (3.4-16.6 days < alachlor (4.4-5.7 days). The correlation analysis and the Principal Component Analysis revealed significant positive correlations between the herbicide degradation rates and the organic matter content of soils. The depth-dependent degradation factors obtained for topsoil and two subsoil horizons (1: 0.42: 0.11 - based on average values, and 1: 0.31: 0.12 - based on median values) reflect the degradation abilities of Polish Luvisols. The values noted are soil-specific; therefore, they can also be applied to other pesticides in Polish Luvisols.
Lithotripsy Performance of Specially Designed Laser Fiber Tips.
Kronenberg, Peter; Traxer, Olivier
2016-05-01
We evaluated and compared a standard laser lithotripsy fiber to laser fibers claimed to have lithotripsy performance enhancing features. A special AccuMax™ 200 polished tip fiber and an AccuTrac™ ball-shaped tip fiber, each with an approximately 240 μm core, were compared to a standard 272 μm core fiber (Rocamed™). The polished and ball-shaped tip fibers were used and reused without preparation. The standard fiber was stripped and cleaved according to manufacturer instructions after each experiment. An automated laser fragmentation testing system was used to perform multiple 30-second laser lithotripsy experiments. To mimic most typical lithotripsy conditions soft and hard stone materials were used with high frequency, low pulse energy (20 Hz and 0.5 J) or with low frequency, high pulse energy (5 Hz and 2.0 J) lithotripter settings. Ablation volumes and laser fiber tip photographs before and after lithotripsy were compared. The standard and ball-shaped tip fibers did not differ in ablation volume (p = 0.72) but they ablated 174% and 188% more stone, respectively, than the polished tip fiber (p <0.0001). The ball-shaped tip showed remarkable fiber tip degradation after short-term use at low frequency, high pulse energy settings. When high pulse energy settings were applied first even for short-term use, the ablation volume achieved by the polished and ball-shaped tip fibers at high frequency, low pulse energy settings decreased more than 20%. The standard laser fiber was as good as and sometimes better than the specially designed fibers. Rapid degradation of the specially designed laser fiber tips strongly limits their general usefulness but ball-shaped tip fibers may be useful in specific situations. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Wichniak, Adam; Jankowski, Konrad S; Skalski, Michal; Skwarło-Sońta, Krystyna; Zawilska, Jolanta B; Żarowski, Marcin; Poradowska, Ewa; Jernajczyk, Wojciech
2017-10-29
Majority of the physiological processes in the human organism are rhythmic. The most common are the diurnal changes that repeat roughly every 24 hours, called circadian rhythms. Circadian rhythms disorders have negative influence on human functioning. The aim of this article is to present the current understanding of the circadian rhythms physiological role, with particular emphasis on the circadian rhythm sleep-wake disorders (CRSWD), principles of their diagnosis and chronobiological therapy. The guidelines are based on the review of recommendations from the scientific societies involved in sleep medicine and the clinical experiences of the authors. Researchers participating in the preparation of guidelines were invited by the Polish Sleep Research Society and the Section of Biological Psychiatry of the Polish Psychiatric Association, based on their significant contributions in circadian rhythm research and/or clinical experience in the treatment of such disorders. Finally, the guidelines were adjusted to the questions and comments given by the members of both Societies. CRSWD have a significant negative impact on human health and functioning. Standard methods used to assess CRSWD are sleep diaries and sleep logs, while the actigraphy, when available, should be also used. The most effective methods of CRSWD treatment are melatonin administration and light therapy. Behavioral interventions are also recommended. Afourteen-day period of sleep-wake rhythm assessment in CRSWD enables accurate diagnosis, adequate selection of chronobiological interventions, and planning adequate diurnal timing of their application. This type of assessment is quite easy, low-cost, and provides valuable indications how to adjust the therapeutic approach to the circadian phase of the particular patient.
NASA Astrophysics Data System (ADS)
McCarter, Colin P. R.; Price, Jonathan S.
2017-06-01
Ladder fen peatlands have excellent potential for wastewater polishing as they naturally contain both open water (pools) and subsurface (peat) treatment landforms; however, there is a poor understanding of solute transport in ladder fens with and without the increased hydrological load imposed by wastewater discharge. To better understand solute transport in ladder fens under wastewater polishing conditions a continuous solute (NaCl) tracer experiment (38 m3 day-1 of water, chloride - 47.2 mg L-1, and sodium - 25.3 mg L-1) was conducted during the summer of 2014 (day of year 192-243) in a small ladder fen in the James Bay Lowland. The transmissivity distribution and effective porosity (average 0.5) of the peat ribs were determined through repeated bail tests and the drainable porosity of 18 peat cores at -100 mb, respectively. Water samples were taken at least every 7 days to capture the solute (sodium and chloride) plumes. Both solute plumes never reached the site outflow (∼250 m downgradient) and displayed complex plume morphology, typically following the patterns of higher hydraulic conductivity within the upper 0.1 m of the saturated peat, rather than the microtopography. Based on the 50% breakthrough isotherms, sodium and chloride were transported at an average solute velocity of 1.9 and 1.1 m day-1, respectively (average linear groundwater velocity = 2.1 m day-1); thus, the solutes were retarded by a factor of 2.1 and 1.2 for sodium and chloride, respectively. Due to the inherent retardation of solutes into inactive pores and relatively high solute residence times, this study demonstrates the potential for wastewater polishing in ladder fens.
Wagner, Monica; Shafer, Valerie L.; Martin, Brett; Steinschneider, Mitchell
2013-01-01
The influence of native-language experience on sensory-obligatory auditory-evoked potentials (AEPs) was investigated in native-English and native-Polish listeners. AEPs were recorded to the first word in nonsense word pairs, while participants performed a syllable identification task to the second word in the pairs. Nonsense words contained phoneme sequence onsets (i.e., /pt/, /pət/, /st/ and /sət/) that occur in the Polish and English languages, with the exception that /pt/ at syllable onset is an illegal phonotactic form in English. P1–N1–P2 waveforms from fronto-central electrode sites were comparable in English and Polish listeners, even though, these same English participants were unable to distinguish the nonsense words having /pt/ and /pət/ onsets. The P1–N1–P2 complex indexed the temporal characteristics of the word stimuli in the same manner for both language groups. Taken together, these findings suggest that the fronto-central P1–N1–P2 complex reflects acoustic feature processing of speech and is not significantly influenced by exposure to the phoneme sequences of the native-language. In contrast, the T-complex from bilateral posterior temporal sites was found to index phonological as well as acoustic feature processing to the nonsense word stimuli. An enhanced negativity for the /pt/ cluster relative to its contrast sequence (i.e., /pət/) occurred only for the Polish listeners, suggesting that neural networks within non-primary auditory cortex may be involved in early cortical phonological processing. PMID:23643857
Ahmad, Rohana; Morgano, Steven M; Wu, Benjamin M; Giordano, Russell A
2005-11-01
Many studies on the strengthening effects of grinding and polishing, as well as heat treatment on ceramics, are not well standardized or use commercially available industrial polishing systems. The reported effectiveness of these strengthening mechanisms on ceramics may not be applicable to clinical dentistry. The purpose of this study was to evaluate the effects of controlled polishing on the flexural strength of dental ceramics by using a custom-made machine that applied standardized loads and speeds that coincided with the mean loads and speeds used by experienced prosthodontists. A total of 140 aluminous dental ceramic bar-shaped specimens (Vitadur Alpha Enamel) measuring 1.5 x 2.0 x 25 mm were fabricated and divided into 12 groups (for most groups, n=10). Specimens were untreated, polished with different polishing systems, polished at different speeds, ground and autoglazed, polished and autoglazed, autoglazed and polished, polished with loose (paste) and bonded abrasives, or overglazed. Simulated clinical polishing was performed on the ceramic specimens by using a customized polishing apparatus that allowed independent control over the relevant polishing parameters (abrasive hardness, applied load, linear speed, rotational velocity, and wheel stiffness). Flexural strength (MPa) was measured with a 4-point bending test, and subjective surface roughness was assessed with scanning electron microscopy. Autoglazing was performed at various stages of the polishing sequence to determine the effects of polishing on surface stresses. Mean values, standard deviations, independent-sample t tests, 1-way and 2-way analyses of variance, Dunnett t tests and Kruskal-Wallis tests were applied to the data (alpha=.05). Under a clinical load of 0.6 N for a coarse polishing wheel, 1.0 N for a medium polishing wheel, and 1.3 N for a fine polishing wheel, a linear speed of 499 mm/min, and a rotational velocity of 10,000 rpm, the use of clinical polishing instruments did not affect the flexural strength of the aluminous ceramics studied (P=.274). At higher rotational velocity (20,000 rpm), specimens polished with the diamond polishing system produced statistically weaker specimens compared with those that had been polished at 10,000 rpm (P=.019). Autoglazing treatment of the diamond-polished specimens did not reverse the strength degradation (P=.125). Conversely, diamond polishing of the autoglazed specimens resulted in significant flexural strength reduction (P=.029). Fine-diamond-bonded abrasive significantly reduced flexural strength (P=.025). Simulated clinical polishing at 10,000 rpm did not appear to substantially strengthen or weaken the ceramic specimens. Polishing at 20,000 rpm reduced flexural strength of the ceramic bars.
Prediction of a nail polish colour applied on a nail.
Monpeurt, C; Cinotti, E; Razafindrakoto, J; Rubegni, P; Fimiani, M; Perrot, J L; Hebert, M
2018-02-01
The colour of a nail polish varies according to the nail on which it is applied. The objective of this study was to predict the colour of the nail polish on a given nail and to study how the colour varies depending on the nail polish thickness. Six nail polishes were applied in one, two and three layers on the nails of one subject, thus forming eighteen samples. The spectral reflectances of the eighteen nail polishes applied on the nails with different thicknesses were obtained by spectrophotometry. The spectral reflectances of the nails without polish were also measured using the same technique. The thicknesses of nail polishes were measured by high-definition optical coherence tomography (HD-OCT). Then, to determine the physical parameters of the nail polish itself, we applied the six nail polishes on an opacity drawdown chart and we measured the spectral reflectance and the thickness of each patch using spectrophotometry and HD-OCT, respectively. The Kubelka-Munk theory was used to get the predicted spectral reflectance of the nail polish applied on the nail according to the polish thickness by knowing the parameter of the polish itself and the spectral reflectance of the nail. The predicted spectral reflectances were finally compared with those measured directly on the nails. The predicted spectral reflectances were rather close to measured ones. Consequently, knowing the colour of the nail without polish and the optical parameters of the nail polish itself, we can estimate the colour of the nail polish applied on the nail depending on its thickness. Our study showed that the Kubelka-Munk theory can be used to predict the nail polish colour. The ability to predict the real colour of a nail polish applied on a nail could help a nail polish manufacturer to improve his polish formulae in order to obtain a precise colour. © 2017 Society of Cosmetic Scientists and the Société Française de Cosmétologie.
Towards a more transparent HTA process in Poland: new Polish HTA methodological guidelines
Lach, Krzysztof; Dziwisz, Michal; Rémuzat, Cécile; Toumi, Mondher
2017-01-01
ABSTRACT Introduction: Health technology assessment (HTA) in Poland supports reimbursement decisions via the Polish HTA Agency (AOTMiT), whose guidelines were updated in 2016. Methods: We identified key changes introduced by the update and, before guideline publication, analysed discrepancies between AOTMiT assessments and the submitting marketing authorisation holders (MAHs) to elucidate the context of the update. We compared the clarity and detail of the new guidelines versus those of the UK’s National Institute for Health and Care Excellence (NICE). Results: The update specified more precise requirements for items such as indirect comparison or input data for economic modelling. Agency–MAH discrepancies relating to the subjects of the HTA update were found in 14.6% of published documents. The new Polish HTA guidelines were as clear and detailed as NICE’s on topics such as assessing quality of evidence and economic modelling, but were less informative when describing (for example) pairwise meta-analysis. Conclusions: The Polish HTA guidelines update demonstrates lessons learned from internal and external experiences. The new guidelines adhere more closely to UK HTA standards, being clearer and more informative. While the update is expected to reduce Agency–MAH discrepancies, there remain areas for development, such as providing templates to aid HTA submissions. PMID:28804603
Knowledge of chronic total occlusion among Polish interventional cardiologists
Zabojszcz, Michał; Dębski, Grzegorz; Marchewka, Jakub; Legutko, Jacek; Surowiec, Sławomir; Siudak, Zbigniew; Żmudka, Krzysztof; Dudek, Dariusz; Bryniarski, Leszek
2015-01-01
Introduction Chronic total occlusion (CTO) recanalization is indicated in patients with symptoms and evidence of ischemia, but in most cases those types of lesions are still treated medically. In the last few years CTO angioplasty technique has changed dramatically due to considerable advances in techniques and dedicated equipment. Aim An attempt to assess the state of knowledge of technical aspects of CTO angioplasty of coronary arteries among Polish interventional cardiologists. Material and methods Questionnaire survey performed during two major Polish invasive cardiology workshops. Results In the study there participated 113 physicians with an average length of work experience of 13 years, most of them cardiologists certified as independent primary operators. The majority of respondents recognized the need of prevention of thrombotic complications through control of activated coagulation time during the CTO procedures. Prevention of renal complications and X-ray protection are also recognized as a significant part of the procedures. The benefits from the use of over-the-wire microcatheters and balloons, the proper choice of dedicated guidewires, contralateral injections and retrograde technique are underestimated. Conclusions Despite satisfactory knowledge about indications and qualification for the CTO procedure, the awareness of procedural aspects (particularly the retrograde technique) as well as the dedicated CTO equipment among Polish interventional cardiologists is still insufficient. PMID:26161099
Attack polish for nickel-base alloys and stainless steels
Steeves, Arthur F.; Buono, Donald P.
1983-01-01
A chemical attack polish and polishing procedure for use on metal surfaces such as nickel base alloys and stainless steels. The chemical attack polish comprises Fe(NO.sub.3).sub.3, concentrated CH.sub.3 COOH, concentrated H.sub.2 SO.sub.4 and H.sub.2 O. The polishing procedure includes saturating a polishing cloth with the chemical attack polish and submicron abrasive particles and buffing the metal surface.
Method of polishing nickel-base alloys and stainless steels
Steeves, Arthur F.; Buono, Donald P.
1981-01-01
A chemical attack polish and polishing procedure for use on metal surfaces such as nickel base alloys and stainless steels. The chemical attack polish comprises Fe(NO.sub.3).sub.3, concentrated CH.sub.3 COOH, concentrated H.sub.2 SO.sub.4 and H.sub.2 O. The polishing procedure includes saturating a polishing cloth with the chemical attack polish and submicron abrasive particles and buffing the metal surface.
Olszowski, Tomasz; Adler, Grażyna; Janiszewska-Olszowska, Joanna; Safranow, Krzysztof; Chlubek, Dariusz
2015-01-01
The aim of the study was to examine the frequencies of the genotypes and alleles of ACE insertion/deletion (I/D) polymorphism and their association with dental caries in a sample of Polish children. The study subjects were 120 children with dental caries experience (cases) and 41 caries-free individuals (controls). The genotyping was performed using polymerase chain reaction. The genotype distributions of ACE I/D polymorphism were not statistically different between carious and control children. However, we found a borderline overrepresentation of the II + ID genotypes versus the DD genotype in the carious compared to the control group (69.2% and 51.2%, respectively, p = 0.057). Logistic regression analysis adjusted for age and sex revealed that I allele carriage was a significant predictor of dental caries susceptibility (OR = 2.14, 95% CI = 1.02-4.49, p = 0.041). In conclusion, the DD genotype of ACE I/D polymorphism might be protective against dental caries in Polish children. © 2015 S. Karger AG, Basel.
Work as a cultural and personal value: attitudes towards work in Polish society.
Skarzyńska, Krystyna
2002-01-01
The meaning of work for Poles is analyzed here from 2 perspectives: macrosocial and individual. From the macrosocial perspective work attitudes are explained by 3 factors: traditional Polish Catholicism, cultural patterns (influence of noble class tradition), and experience of "real socialism." From an individual perspective some psychological and demographic predictors of an autonomous (intrinsic) work attitude are empirically tested. The autonomous attitude towards work is understood here as treating work as an important autonomous value versus only an instrumental means for earning money. The data was collected by means of standardized interviews run on a representative random sample of adult working Poles, N = 1340.
Fatigue, Creep-Fatigue, and Thermomechanical Fatigue Life Testing of Alloys
NASA Technical Reports Server (NTRS)
Halford, Gary R.; Lerch, Bradley A.; McGaw, Michael A.
2000-01-01
The fatigue crack initiation resistance of an alloy is determined by conducting a series of tests over a range of values of stress amplitude or strain range. The observed number of cycles to failure is plotted against the stress amplitude or strain range to obtain a fatigue curve. The fatigue properties quoted for an alloy are typically the constants used in the equation(s) that describe the fatigue curve. Fatigue lives of interest may be as low as 10(exp 2) or higher than 10(exp 9) cycles. Because of the enormous scatter associated with fatigue, dozens of tests may be needed to confidently establish a fatigue curve, and the cost may run into several thousands of dollars. To further establish the effects on fatigue life of the test temperature, environment, alloy condition, mean stress effects, creep-fatigue effects, thermomechanical cycling, etc. requires an extraordinarily large and usually very costly test matrix. The total effort required to establish the fatigue resistance of an alloy should not be taken lightly. Fatigue crack initiation tests are conducted on relatively small and presumed to be initially crack-free, samples of an alloy that are intended to be representative of the alloy's metallurgical and physical condition. Generally, samples are smooth and have uniformly polished surfaces within the test section. Some may have intentionally machined notches of well-controlled geometry, but the surface at the root of the notch is usually not polished. The purpose of polishing is to attain a reproducible surface finish. This is to eliminate surface finish as an uncontrolled variable. Representative test specimen geometries will be discussed later. Test specimens are cyclically loaded until macroscopically observable cracks initiate and eventually grow to failure. Normally, the fatigue failure life of a specimen is defined as the number of cycles to separation of the specimen into two pieces. Alternative definitions are becoming more common, particularly for low-cycle fatigue testing, wherein some prescribed indication of impending failure due to cracking is adopted. Specific criteria will be described later. As a rule, cracks that develop during testing are not measured nor are the test parameters intentionally altered owing to the presence of cracking.
Research on the magnetorheological finishing (MRF) technology with dual polishing heads
NASA Astrophysics Data System (ADS)
Huang, Wen; Zhang, Yunfei; He, Jianguo; Zheng, Yongcheng; Luo, Qing; Hou, Jing; Yuan, Zhigang
2014-08-01
Magnetorheological finishing (MRF) is a key polishing technique capable of rapidly converging to the required surface figure. Due to the deficiency of general one-polishing-head MRF technology, a dual polishing heads MRF technology was studied and a dual polishing heads MRF machine with 8 axes was developed. The machine has the ability to manufacture large aperture optics with high figure accuracy. The large polishing head is suitable for polishing large aperture optics, controlling large spatial length's wave structures, correcting low-medium frequency errors with high removal rates. While the small polishing head has more advantages in manufacturing small aperture optics, controlling small spatial wavelength's wave structures, correcting mid-high frequency and removing nanoscale materials. Material removal characteristic and figure correction ability for each of large and small polishing head was studied. Each of two polishing heads respectively acquired stable and valid polishing removal function and ultra-precision flat sample. After a single polishing iteration using small polishing head, the figure error in 45mm diameter of a 50 mm diameter plano optics was significantly improved from 0.21λ to 0.08λ by PV (RMS 0.053λ to 0.015λ). After three polishing iterations using large polishing head , the figure error in 410mm×410mm of a 430mm×430mm large plano optics was significantly improved from 0.40λ to 0.10λ by PV (RMS 0.068λ to 0.013λ) .This results show that the dual polishing heads MRF machine not only have good material removal stability, but also excellent figure correction capability.
[Artur Wołyński--A forgotten Polish historian in Italy in the second half of the 19th century].
Piskurewicz, Jan
2011-01-01
Artur Wołyński (1844-1893) was, undoubtedly, one of the most interesting personages of Polish émigrés after January Uprising. He belonged to these circles of Polish émigrés, who were able to reconcile their patriotic aspirations with realities and interest of the countries that entertained them. As far as Wołyński is concerned, it found its expression in the efforts that were made in order to assimilate two nations--Polish and Italian people--appealing to the common history and familiar cultural traditions. An important element of integrating all the above-discussed actions was his scientific activity. The mentioned activity included, first of all, his studies on Nicolaus Copernicus and Galileo Galilei. In the article were analyzed more comprehensive scientific descriptions dedicated to Copernicus and Galileo prepared by Wołyński, and their significance and opinions on them of the learned, whose works treated on Copernicus and Galileo as well. Secondly, in the field of scientific activity of Wołyńiski, one can also observe his researches and the process of elaborating sources for Polish and Italian his tory, particularly concerning the 17th century. However, most of his attention Wołyński paid to collecting and working out the materials concerning January Uprising. Speaking a modern language, one can say that Wołyński in a way polled the insurgents of January Uprising sending to them an appropriate list of questions, additionally allowing for their biographies. In the paper was also included a detailed description of this broad initiative together with its results. Up till now, not much attention has been paid to this significant scientific activity and its contexts. So, the present article is to remind of meritorious personage of Wołyński, and particularly of his output within the realm of history of science, history of Polish and Italian relationships, and of the role he played in bequeathing memory of January Uprising.
NASA Technical Reports Server (NTRS)
DellaCorte, Christopher; Stanford, malcolm K.; Thomas, Fransua; Edmonds, Brian J.
2010-01-01
A new composite, multi-constituent, solid lubricant coating, NASA PS400, developed for high temperature tribological applications, exhibits a smoother surface finish after grinding and polishing than its predecessors PS200 and PS300. In this paper, the baseline composition of PS400 is modified to investigate each individual constituent s role on the achievable surface finish through a series of coating deposition, grinding, and polishing experiments. Furthermore, to explore the limits of compositional tailoring for improved tribological performance, several PS400 coatings were doped with additional solid lubricants (graphite, MoS2 and BN) and tribologically tested. The test results clearly showed that, compared to PS300 coatings, PS400 achieves a smoother surface finish via a reduced lubricant content. Coatings prepared with higher than the baseline level (10 wt%) of lubricants exhibited higher final surface roughness than the earlier generation PS300 coatings. Reducing or eliminating the one or both lubricants (fluorides or silver) did not further improve the surface finish suggesting that the current composition of PS400 is near optimal with respect to surface finish. Lastly, attempts to improve the poor initial room temperature tribological behavior of PS400 via the addition of traditional solid lubricants were unsuccessful. Based upon this work and earlier results it is expected that future research will concentrate on developing methods to produce a lubricious glaze on the rubbing surface during break in to ensure that low friction and wear are rapidly achieved.
NASA Astrophysics Data System (ADS)
Yoshimura, Shumpei; Nakamura, Michihiko
2010-09-01
The healing of magmatic fractures is considered essential to repetitive seismicity and the closure of degassing paths during emplacement of lavas. To estimate the healing time of magmatic fractures, we performed healing experiments on rhyolitic melts at 850°-1000°C and 1.6-3.2 MPa for 0.5-94 h. Two cylindrical obsidian cores were juxtaposed on surfaces prepared by cutting the cores both with and without polishing. These were annealed in an open-system cell. The contact interface became coherent and finally disappeared. The water content across the contact initially decreased toward the interface via diffusive dehydration, but later homogenized. This change was interpreted to reflect atomic-scale closure of the interface, probably by chemical bonding. We defined this closure interval as microscopic healing time and determined this by fitting the measured profiles with a diffusion model. The microscopic healing time was strongly dependent on temperature and roughness of the interface and was, for the nonpolished interfaces, 67-74, 4.0-4.9, and 0.36-0.38 h at 850°, 900°, and 950°C, respectively, whereas for the polished examples it was 1-3 and 0.5-0.6 h at 850° and 900°C, respectively. This microscopic healing time is consistent with the period of actual seismicity and is prolonged sufficiently to permit the formation of millimeter-thick bubble-free obsidian layers along fractures in vesicular lavas through bubble resorption due to diffusive degassing.
Center removal amount control of magnetorheological finishing process by spiral polishing way
NASA Astrophysics Data System (ADS)
Wang, Yajun; He, Jianguo; Ji, Fang; Huang, Wen; Xiao, Hong; Luo, Qing; Zheng, Yongcheng
2010-10-01
Spiral polishing is a traditional process of computer-controlled optical surfacing. However, the additional polishing amount is great and the center polishing amount is difficult to control. At first, a simplified mathematics model is presented for magnetorheological finishing, which indicates that the center polishing amount and additional polishing amount are proportional to the length and peak value of magnetorheological finishing influence function, and are inversely proportional to pitch and rotation rate of spiral track, and the center polishing amount is much bigger than average polishing amount. Secondly, the relationships of "tool feed way and center polishing amount", "spiral pitch and calculation accuracy of influence matrix for dwell time function solution", "spiral pitch and center polishing amount" and "peak removal rate, dimensions of removal function and center removal amount" are studied by numerical computation by Archimedes spiral path. It shows that the center polishing amount is much bigger in feed stage than that in backhaul stage when the head of influence function is towards workpiece edge in feeding; and the bigger pitch, the bigger calculation error of influence matrix elements; and the bigger pitch, the smaller center polishing amount, and the smaller peak removal rate and dimensions of removal function, the smaller center removal amount. At last, the polishing results are given, which indicates that the center polishing amount is acceptable with a suitable polishing amount rate of feed stage and backhaul stage, and with a suitable spiral pitch during magnetorheological finishing procedure by spiral motion way.
NASA Astrophysics Data System (ADS)
Huang, Wei-Ren; Huang, Shih-Pu; Tsai, Tsung-Yueh; Lin, Yi-Jyun; Yu, Zong-Ru; Kuo, Ching-Hsiang; Hsu, Wei-Yao; Young, Hong-Tsu
2017-09-01
Spherical lenses lead to forming spherical aberration and reduced optical performance. Consequently, in practice optical system shall apply a combination of spherical lenses for aberration correction. Thus, the volume of the optical system increased. In modern optical systems, aspherical lenses have been widely used because of their high optical performance with less optical components. However, aspherical surfaces cannot be fabricated by traditional full aperture polishing process due to their varying curvature. Sub-aperture computer numerical control (CNC) polishing is adopted for aspherical surface fabrication in recent years. By using CNC polishing process, mid-spatial frequency (MSF) error is normally accompanied during this process. And the MSF surface texture of optics decreases the optical performance for high precision optical system, especially for short-wavelength applications. Based on a bonnet polishing CNC machine, this study focuses on the relationship between MSF surface texture and CNC polishing parameters, which include feed rate, head speed, track spacing and path direction. The power spectral density (PSD) analysis is used to judge the MSF level caused by those polishing parameters. The test results show that controlling the removal depth of single polishing path, through the feed rate, and without same direction polishing path for higher total removal depth can efficiently reduce the MSF error. To verify the optical polishing parameters, we divided a correction polishing process to several polishing runs with different direction polishing paths. Compare to one shot polishing run, multi-direction path polishing plan could produce better surface quality on the optics.
The Beginnings of Modern Research on Propolis in Poland
Kłósek, Małgorzata; Król, Wojciech
2013-01-01
Propolis studies in Poland were initiated by Professor Stan Scheller in the 1960s. It was a team of Polish researchers who developed a method of introducing hydrophobic ethanol extracts of propolis (EEP) into aqueous solutions, which enabled the study of their biological properties. The studies performed in Poland showed that EEP possesses antioxidant, radioprotective, and immunostimulating properties. It was possible to demonstrate antibacterial activity of propolis on Gram-positive bacteria, virulent Mycobacterium tuberculosis, and protozoa as well as stimulating activity of aqueous extracts of propolis on proliferation of cells in vitro. Polish investigators showed that propolis stimulates regeneration of tissue, acts as antioxidant and radioprotector, has strong immunostimulative properties, affects animals' life span by extending it, and improves intellectual and life functions of the elderly. PMID:23864903
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suratwala, T I; Miller, P E; Menapace, J A
The objective of this work is to develop a solid scientific understanding of the creation and characteristics of surface fractures formed during the grinding and polishing of brittle materials, specifically glass. In this study, we have experimentally characterized the morphology, number density, and depth distribution of various surface cracks as a function of various grinding and polishing processes (blanchard, fixed abrasive grinding, loose abrasive, pitch polishing and pad polishing). Also, the effects of load, abrasive particle (size, distribution, foreign particles, geometry, velocity), and lap material (pitch, pad) were examined. The resulting data were evaluated in terms of indentation fracture mechanicsmore » and tribological interactions (science of interacting surfaces) leading to several models to explain crack distribution behavior of ground surfaces and to explain the characteristics of scratches formed during polishing. This project has greatly advanced the scientific knowledge of microscopic mechanical damage occurring during grinding and polishing and has been of general interest. This knowledge-base has also enabled the design and optimization of surface finishing processes to create optical surfaces with far superior laser damage resistance. There are five major areas of scientific progress as a result of this LDRD. They are listed in Figure 1 and described briefly in this summary below. The details of this work are summarized through a number of published manuscripts which are included this LDRD Final Report. In the first area of grinding, we developed a technique to quantitatively and statistically measure the depth distribution of surface fractures (i.e., subsurface damage) in fused silica as function of various grinding processes using mixtures of various abrasive particles size distributions. The observed crack distributions were explained using a model that extended known, single brittle indentation models to an ensemble of loaded, sliding particles. The model illustrates the importance of the particle size distribution of the abrasive and its influence on the resulting crack distribution. The results of these studies are summarized in references 1-7. In the second area of polishing, we conducted a series of experiments showing the influence of rogue particles (i.e., particles in the polishing slurry that are larger than base particles) on the creation of scratches on polished surfaces. Scratches can be thought of a as a specific type of sub-surface damage. The characteristics (width, length, type of fractures, concentration) were explained in terms of the rogue particle size, the rogue particle material, and the viscoelastic properties of the lap. The results of these studies are summarized in references 6-7. In the third area of etching, we conducted experiments aimed at understanding the effect of HF:NH{sub 4}F acid etching on surface fractures on fused silica. Etching can be used as a method: (a) to expose sub-surface mechanical damage, (b) to study the morphology of specific mechanical damage occurring by indentation, and (c) to convert a ground surface containing a high concentration of sub-surface mechanical damage into surface roughness. Supporting models have been developed to describe in detail the effect of etching on the morphology and evolution of surface cracks. The results of these studies are summarized in references 8-9. In the fourth area of scratch forensics or scratch fractography, a set of new scratch forensic rule-of-thumbs were developed in order to aid the optical fabricator and process engineer to interpret the cause of scratches and digs on surfaces. The details of how these rules were developed are described in each of the references included in this summary (1-9). Figure 2 provides as a summary of some of the more commonly used rules-of-thumbs that have been developed in this study. In the fifth and final area of laser damage, we demonstrated that the removal of such surface fractures from the surface during optical fabrication can dramatically improve the laser damage.« less
Kakaboura, A; Vougiouklakis, G; Argiri, G
1989-01-01
Finishing and polishing an amalgam restoration, is considered as an important and necessary step of the restorative procedure. Various polishing techniques have been recommended to success a smooth amalgam surface. The aim of this study was to investigate the influence of three different polishing treatments on the marginal integrity and surface smoothness of restorations made of three commercially available amalgams and a glass-cermet cement. The materials used were the amalgams, Amalcap (Vivadent), Dispersalloy (Johnson and Johnson), Duralloy (Degussa) and the glass-cermet Katac-Silver (ESPE). The occlusal surfaces of the restorations were polished by the methods: I) round bur, No4-rubber cup-zinc oxide paste in a small brush, II) round bur No 4-bur-brown, green and super green (Shofu) polishing cups and points successively and III) amalgam polishing bur of 12-blades-smooth amalgam polishing bur. Photographs from unpolished and polished surfaces of the restorations, were taken with scanning electron microscope, to evaluate the polishing techniques. An improvement of marginal integrity and surface smoothness of all amalgam restorations was observed after the specimens had been polished with the three techniques. Method II, included Shofu polishers, proved the best results in comparison to the methods I and III. Polishing of glass-cermet cement was impossible with the examined techniques.
Steinebach, Fabian; Müller-Späth, Thomas; Morbidelli, Massimo
2016-09-01
The economic advantages of continuous processing of biopharmaceuticals, which include smaller equipment and faster, efficient processes, have increased interest in this technology over the past decade. Continuous processes can also improve quality assurance and enable greater controllability, consistent with the quality initiatives of the FDA. Here, we discuss different continuous multi-column chromatography processes. Differences in the capture and polishing steps result in two different types of continuous processes that employ counter-current column movement. Continuous-capture processes are associated with increased productivity per cycle and decreased buffer consumption, whereas the typical purity-yield trade-off of classical batch chromatography can be surmounted by continuous processes for polishing applications. In the context of continuous manufacturing, different but complementary chromatographic columns or devices are typically combined to improve overall process performance and avoid unnecessary product storage. In the following, these various processes, their performances compared with batch processing and resulting product quality are discussed based on a review of the literature. Based on various examples of applications, primarily monoclonal antibody production processes, conclusions are drawn about the future of these continuous-manufacturing technologies. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The effect of strain hardening on resistance to electrochemical corrosion of wires for orthopaedics
NASA Astrophysics Data System (ADS)
Przondziono, J.; Walke, W.; Hadasik, E.; Szymszal, J.
2012-05-01
The purpose of this research is to evaluate electrochemical corrosion resistance of wire with modified surface, made of stainless steel of Cr-Ni-Mo type, widely used in implants for orthopaedics, depending on hardening created in the process of drawing. Tests have been carried out in the environment imitating human osseous tissue. Pitting corrosion was determined on the ground of registered anodic polarisation curves by means of potentiodynamic method with application of electrochemical testing system VoltaLab® PGP 201. Wire corrosion tests were carried out in Tyrode solution on samples that were electrochemically polished as well as electrochemically polished and finally chemically passivated. Initial material for tests was wire rod made of X2CrNiMo17-12-2 steel with diameter of 5.5 mm in supersaturated condition. Wire rod was drawn up to diameter of 1.35 mm. This work shows the course of flow curve of wire made of this grade of steel and mathematical form of yield stress function. The study also presents exemplary curves showing the dependence of polarisation resistance in strain function in the drawing process of electrochemically passivated and electrochemically polished and then chemically passivated wire.
Optimal Magnetorheological Fluid for Finishing of Chemical-Vapor-Deposited Zinc Sulfide
NASA Astrophysics Data System (ADS)
Salzman, Sivan
Magnetorheological finishing (MRF) of polycrystalline, chemical-vapor- deposited zinc sulfide (ZnS) optics leaves visible surface artifacts known as "pebbles". These artifacts are a direct result of the material's inner structure that consists of cone-like features that grow larger (up to a few millimeters in size) as deposition takes place, and manifest on the top deposited surface as "pebbles". Polishing the pebble features from a CVD ZnS substrate to a flat, smooth surface to below 10 nm root-mean-square is challenging, especially for a non-destructive polishing process such as MRF. This work explores ways to improve the surface finish of CVD ZnS processed with MRF through modification of the magnetorheological (MR) fluid's properties. A materials science approach is presented to define the anisotropy of CVD ZnS through a combination of chemical and mechanical experiments and theoretical predictions. Magnetorheological finishing experiments with single crystal samples of ZnS, whose cuts and orientations represent most of the facets known to occur in the polycrystalline CVD ZnS, were performed to explore the influence of material anisotropy on the material removal rate during MRF. By adjusting the fluid's viscosity, abrasive type concentration, and pH to find the chemo-mechanical conditions that equalize removal rates among all single crystal facets during MRF, we established an optimized, novel MR formulation to polish CVD ZnS without degrading the surface finish of the optic.
Neuroengineering control and regulation of behavior
NASA Astrophysics Data System (ADS)
Wróbel, A.; Radzewicz, C.; Mankiewicz, L.; Hottowy, P.; Knapska, E.; Konopka, W.; Kublik, E.; Radwańska, K.; Waleszczyk, W. J.; Wójcik, D. K.
2014-11-01
To monitor neuronal circuits involved in emotional modulation of sensory processing we proposed a plan to establish novel research techniques combining recent biological, technical and analytical discoveries. The project was granted by National Science Center and we started to build a new experimental model for studying the selected circuits of genetically marked and behaviorally activated neurons. To achieve this goal we will combine the pioneering, interdisciplinary expertise of four Polish institutions: (i) the Nencki Institute of Experimental Biology (Polish Academy of Sciences) will deliver the expertise on genetically modified mice and rats, mapping of the neuronal circuits activated by behavior, monitoring complex behaviors measured in the IntelliCage system, electrophysiological brain activity recordings by multielectrodes in behaving animals, analysis and modeling of behavioral and electrophysiological data; (ii) the AGH University of Science and Technology (Faculty of Physics and Applied Computer Sciences) will use its experience in high-throughput electronics to build multichannel systems for recording the brain activity of behaving animals; (iii) the University of Warsaw (Faculty of Physics) and (iv) the Center for Theoretical Physics (Polish Academy of Sciences) will construct optoelectronic device for remote control of opto-animals produced in the Nencki Institute based on the unique experience in laser sources, studies of light propagation and its interaction with condensed media, wireless medical robotic systems, fast readout opto-electronics with control software and micromechanics.
Polymer optical fiber tapering using chemical solvent and polishing
NASA Astrophysics Data System (ADS)
Supian, L. S.; Syuhaimi Ab-Rahman, Mohd; Arsad, Norhana
2017-11-01
A method for developing polymer optical fiber (POF) directional coupler is introduced where the initial procedure includes using chemical solvent to remove the cladding, and bare out the core in order to align the unclad center of the fiber with other similar fiber to develop a coupler. The process is safe, simple, inexpensive and require low operation skill. The etched fiber offers improvement to the performance of various POF devices, i.e, couplers and sensors. Instead of relying only on silica or glass fiber, POF now can be used as an alternative to improve the network performance in short distance communication system. The measurement parameters laid out offer great outcomes. However, the couplers intended to be developed is yet to be realized, where deeper research and various experiments are needed in order to develop a simple but optimum performance coupler that can be used for various applications.
Vrochari, Areti D; Petropoulou, Aikaterini; Chronopoulos, Vasilios; Polydorou, Olga; Massey, Ward; Hellwig, Elmar
2017-06-01
To evaluate and compare the mean surface roughness (Ra) of one ceramic and one resin composite material used for indirect restorations, after grinding and repolishing by intraoral means. The materials used were the lithium disilicate glass ceramic IPS e.max Press (EMP) and the indirect resin composite restoration system Gradia (GR). Twelve specimen disks were prepared from each material according to the manufacturer of each material. Five initial measurements of the Ra (Ra 1 ) were made on each specimen as a referral basis, and the specimens were ground with a fine (red) diamond bur. The specimens were repolished using (a) Komet Dialite Polishing Kit for EMP and (b) Enhance Finishing and Polishing System and Prisma Gloss Polishing Paste for GR. Five final Ra (Ra 2 ) measurements were performed on each specimen. All measurements were made using a laser profilometer. Scanning electron microscopy (SEM) was also used to visualize the initial surface morphology and the morphological changes on the specimens' surface after repolishing. A highly significant difference was found between Ra 1EMP and Ra 2EMP (p < 0.001), between Ra 1GR and Ra 2GR (p < 0.001), as well as between Ra 2EMP and Ra 2GR (p < 0.001), when compared in pairs. A highly significant difference (p < 0.001) was also found between ΔRa EMP and ΔRa GR , with ΔRa GR being higher than ΔRa EMP . The Ra GR values were higher than the Ra EMP values at all times. SEM revealed that both EMP and GR repolished surfaces presented with irregularities; however, in GR specimens major voids and craters were present. EMP was found to perform better when polished by intraoral means compared with GR. Both materials exhibited Ra 2 above the critical threshold for increased plaque accumulation and periodontal inflammation. If enamel-to-enamel roughness found in occlusal contact areas is considered as baseline, both materials were clinically acceptable after repolishing. © 2015 by the American College of Prosthodontists.
Building a Foundation for Civic Education in Poland's Schools. Final Report.
ERIC Educational Resources Information Center
Remy, Richard C.; And Others
This document is the report of a project to strengthen democratic reforms in Poland by enhancing student and teacher understanding of citizenship in a democracy. The goal of the initiative is to promote the development of democracy in Poland by instituting a new citizenship curriculum in Polish schools. The immediate goal of this project was to…
Encountering the Past in the Present: An Exploratory Study of Educational Heritage Tourism
ERIC Educational Resources Information Center
Gross, Magdalena H.; Kelman, Ari Y.
2017-01-01
This article presents an educational programme designed to explore the multicultural history of Poland. Targeting Jewish and non-Jewish students of Polish heritage, the "Polonia Programme" (PP) was conceptualised with the aim of applying the tools of experiential education to initiate a new approach to examining one of the world's most…
Effect of Polishing Systems on Surface Roughness and Topography of Monolithic Zirconia.
Goo, C L; Yap, Auj; Tan, Kbc; Fawzy, A S
2016-01-01
This study evaluated the effect of different chairside polishing systems on the surface roughness and topography of monolithic zirconia. Thirty-five monolithic zirconia specimens (Lava PLUS, 3M ESPE) were fabricated and divided into five groups of seven and polished with the following: Group 1 (WZ)-Dura white stone followed by Shofu zirconia polishing kit; Group 2 (SZ)-Shofu zirconia polishing kit; Group 3 (CE)-Ceramiste porcelain polishers; Group 4 (CM)-Ceramaster porcelain polishers; and Group 5 (KZ)-Komet ZR zirconia polishers. All specimens were ground with a fine-grit diamond bur prior to polishing procedures to simulate clinical finishing. Baseline and post-polishing profilometric readings were recorded and delta Ra values (difference in mean surface roughness before and after polishing) were computed and analyzed using one-way analysis of variance and Scheffe post hoc test (p<0.05). Representative scanning electron microscopy (SEM) images of the ground but unpolished and polished specimens were acquired. Delta Ra values ranged from 0.146 for CE to 0.400 for KZ. Delta Ra values for KZ, WZ, and SZ were significantly greater than for CE. Significant differences in delta Ra values were also observed between KZ and CM. The SEM images obtained were consistent with the profilometric findings. Diamond-impregnated polishing systems were more effective than silica carbide-impregnated ones in reducing the surface roughness of ground monolithic zirconia.
Wings, Oliver; Sander, P. Martin
2006-01-01
Polished pebbles occasionally found within skeletons of giant herbivorous sauropod dinosaurs are very likely to be gastroliths (stomach stones). Here, we show that based on feeding experiments with ostriches and comparative data for relative gastrolith mass in birds, sauropod gastroliths do not represent the remains of an avian-style gastric mill. Feeding experiments with farm ostriches showed that bird gastroliths experience fast abrasion in the gizzard and do not develop a polish. Relative gastrolith mass in sauropods (gastrolith mass much less than 0.1% of body mass) is at least an order of magnitude less than that in ostriches and other herbivorous birds (gastrolith mass approximates 1% of body mass), also arguing against the presence of a gastric mill in sauropods. Sauropod dinosaurs possibly compensated for their limited oral processing and gastric trituration capabilities by greatly increasing food retention time in the digestive system. Gastrolith clusters of some derived theropod dinosaurs (oviraptorosaurs and ornithomimosaurs) compare well with those of birds, suggesting that the gastric mill evolved in the avian stem lineage. PMID:17254987
Effects of the LDEF orbital environment on the reflectance of optical mirror materials
NASA Technical Reports Server (NTRS)
Herzig, Howard; Fleetwood, Charles, Jr.
1995-01-01
Specimens of eight different optical mirror materials were flown in low earth orbit as part of the Long Duration Exposure Facility (LDEF) manifest to determine their ability to withstand exposure to the residual atomic oxygen and other environmental effects at those altitudes. Optical thin films of aluminum, gold, iridium, osmium, platinum, magnesium fluoride-overcoated aluminum and reactively deposited, silicon monoxide-protected aluminum, all of which were vacuum deposited on polished fused silica substrates, were included as part of Experiment S0010, Exposure of Spacecraft Coatings. Two specimens of polished, chemical vapor deposited (CVD) silicon carbide were installed in sites available in Experiment A0114, Interaction of Atomic Oxygen with Solid Surfaces at Orbital Altitudes, which included trays in two of the spacecraft bays, one on the leading edge and the other on the trailing edge. One of the silicon carbide samples was located in each of these trays. This paper will compare specular reflectance data from the preflight and postflight measurements made on each of these samples and attempt to explain the changes in light of the specific environments to which the experiments were exposed.
NASA Astrophysics Data System (ADS)
Trzeciak, Maciej; Majdański, Mariusz; Białas, Sebastian; Gaczyński, Edward; Maksym, Andrzej
2015-04-01
Braniewo2014 reflection and refraction experiment was realized in cooperation between Polish Oil and Gas Company (PGNiG) and the Institute of Geophysics (IGF), Polish Academy of Sciences, near the locality of Braniewo in northern Poland. PGNiG realized a 20-km-long reflection profile, using vibroseis and dynamite shooting; the aim of the reflection survey was to characterise Silurian shale gas reservoir. IGF deployed 59 seismic stations along this profile and registered additional full-spread wide-angle refraction and reflection data, with offsets up to 12 km; maximum offsets from the seismic reflection survey was 3 km. To improve the velocity information two velocity logs from near deep boreholes were used. The main goal of the joint reflection-refraction interpretation was to find relations between velocity field from reflection velocity analysis and refraction tomography, and to build a velocity model which would be consistent for both, reflection and refraction, datasets. In this paper we present imaging results and velocity models from Braniewo2014 experiment and the methodology we used.
Chowdhary, Zoya; Mohan, Ranjana
2018-01-01
Tooth polishing is an integral part of clinical dentistry. The main purpose of polishing is to smoothen the surface of the tooth and minimize the deposition of plaque to allow a healthy periodontal maintenance postscaling. Today, polishing by different methods is available to a clinician. Traditional bristle brush and rubber-cup polishing are being widely practiced and gradually getting replaced by novel air polisher. Pros and cons of each method should be weighed before its clinical applications. To evaluate and compare the efficiency of three different polishing systems on enamel as well as on cementum surfaces by scanning electron microscope (SEM). A total of 120 samples were divided into three groups randomly - Group 1 (bristle brush), Group 2 (rubber cup), and Group 3 (air polisher) - with 20 samples each of enamel and cementum, which were subdivided into 10 control and 10 test group (subjected to polishing). The samples were analyzed by SEM at ×1000 magnification, and the data obtained were compiled and subjected to statistical analysis. Polishing with bristle brush demonstrated less surface roughness and debris when compared to air polisher at P = 0.58, P = 0.03 for enamel surface and P = 0.003, P = 0.21 for cementum, respectively. The surface roughness was reduced considerably by rubber cup at P = 0.03 for enamel and P = 0.003 for cementum, compared to air polisher at P = 0.99 and P = 0.21 for enamel and cementum, respectively. The results indicate that polishing with rubber cup was more effective and statistically significant when compared to bristle brush polishing and air polisher for the crown and root surface smoothening and debris removal.
Main, Izabella
2016-08-01
This paper focuses on the diversity in patients' experience of bio-medicine and contrasts it with the normative view characteristic of health professionals. Ethnographic fieldwork among Polish migrant women in London, Barcelona and Berlin included interviews about their experiences with local healthcare and health professionals. Themes drawn from the narratives are differences between the cities in terms of communication between patients and health professionals, respect for patients' choices and dignity, attitudes to pregnancy and birth (different levels of medicalization), and paediatric care. It is argued that patients continuously negotiate among their own views and expectations based on previous experiences and knowledge from personal communication; internet forums and publications; and the offer of medical services in the countries of their settlement. Patients experience pluralism of therapeutic traditions within and outside bio-medicine. In turn, representatives of bio-medicine are rarely aware of other medical practices and beliefs and this leads to various misunderstandings. By highlighting the pluralism of medical practices in European countries and the increasing mobility of patients, this case study has useful implications for medical anthropologists and health professionals in a broader Western context, such as raising sensitivity to different communication strategies and a diversity of curing traditions and expectations.
Attack polish for nickel-base alloys and stainless steels
Not Available
1980-05-28
A chemical attack polish and polishing procedure for use on metal surfaces such as nickel base alloys and stainless steels is described. The chemical attack polich comprises FeNO/sub 3/, concentrated CH/sub 3/COOH, concentrated H/sub 2/SO/sub 4/ and H/sub 2/O. The polishing procedure includes saturating a polishing cloth with the chemical attack polish and submicron abrasive particles and buffing the metal surface.
Pornography Use and Sexual Behavior Among Polish and German University Students.
Martyniuk, Urszula; Briken, Peer; Sehner, Susanne; Richter-Appelt, Hertha; Dekker, Arne
2016-08-17
The purpose of this study was to explore the relationship between pornography use and sexual behavior in young adults from two culturally different countries. Data were collected in an online survey among German (n = 1,303; G) and Polish (n = 1,135; P) university students aged 18 to 26 years. Pornography use was associated with engaging in a greater variety of sexual activities (e.g., sexual role playing, using sex toys; G > P) rather than with a high number of sex partners or condom use consistency. The differences between the samples were found primarily for females (in anal sex experience and age at the first sexual intercourse; G > P).
NASA Astrophysics Data System (ADS)
Du, Hang; Song, Ci; Li, Shengyi
2018-01-01
In order to obtain high precision and high surface quality silicon carbide mirrors, the silicon carbide mirror substrate is subjected to surface modification treatment. In this paper, the problem of Silicon Carbide (SiC) mirror surface roughness deterioration by MRF is studied. The reasons of surface flaws of “Comet tail” are analyzed. Influence principle of MRF polishing depth and the surface roughness of modified SiC mirrors is obtained by experiments. On this basis, the united process of modified SiC mirrors is proposed which is combined MRF with the small grinding head CCOS. The united process makes improvement in the surface accuracy and surface roughness of modified SiC mirrors.
NASA Technical Reports Server (NTRS)
Ahmad, Anees
1990-01-01
The development of in-house integrated optical performance modelling capability at MSFC is described. This performance model will take into account the effects of structural and thermal distortions, as well as metrology errors in optical surfaces to predict the performance of large an complex optical systems, such as Advanced X-Ray Astrophysics Facility. The necessary hardware and software were identified to implement an integrated optical performance model. A number of design, development, and testing tasks were supported to identify the debonded mirror pad, and rebuilding of the Technology Mirror Assembly. Over 300 samples of Zerodur were prepared in different sizes and shapes for acid etching, coating, and polishing experiments to characterize the subsurface damage and stresses produced by the grinding and polishing operations.
Form control in atmospheric pressure plasma processing of ground fused silica
NASA Astrophysics Data System (ADS)
Li, Duo; Wang, Bo; Xin, Qiang; Jin, Huiliang; Wang, Jun; Dong, Wenxia
2014-08-01
Atmospheric Pressure Plasma Processing (APPP) using inductively coupled plasma has demonstrated that it can achieve comparable removal rate on the optical surface of fused silica under the atmosphere pressure and has the advantage of inducing no sub-surface damage for its non-contact and chemical etching mechanism. APPP technology is a cost effective way, compared with traditional mechanical polishing, magnetorheological finishing and ion beam figuring. Thus, due to these advantages, this technology is being tested to fabricate large aperture optics of fused silica to help shorten the polishing time in optics fabrication chain. Now our group proposes to use inductively coupled plasma processing technology to fabricate ground surface of fused silica directly after the grinding stage. In this paper, form control method and several processing parameters are investigated to evaluate the removal efficiency and the surface quality, including the robustness of removal function, velocity control mode and tool path strategy. However, because of the high heat flux of inductively coupled plasma, the removal depth with time can be non-linear and the ground surface evolvement will be affected. The heat polishing phenomenon is founded. The value of surface roughness is reduced greatly, which is very helpful to reduce the time of follow-up mechanical polishing. Finally, conformal and deterministic polishing experiments are analyzed and discussed. The form error is less 3%, before and after the APPP, when 10μm depth of uniform removal is achieved on a 60×60mm ground fused silica. Also, a basin feature is fabricated to demonstrate the figuring capability and stability. Thus, APPP is a promising technology in processing the large aperture optics.
Influence of surface finishing on fracture load and failure mode of glass ceramic crowns.
Mores, Rafael Tagliari; Borba, Márcia; Corazza, Pedro Henrique; Della Bona, Álvaro; Benetti, Paula
2017-10-01
Ceramic restorations often require adjustments using diamond rotary instruments, which damage the glazed surface. The effect of these adjustments on the fracture behavior of these restorations is unclear. The purpose of this in vitro study was to evaluate the influence of induced surface defects on the fracture load and mode of failure of lithium disilicate-based (LDS) glass ceramic restorations. Premolar crowns were obtained from LDS computer-aided design and computer-aided manufacturing blocks (n=60) and glazed. The crowns were bonded to dentin analog dies and divided into 5 groups (n=12), as follows: glaze; abrasion (diamond rotary instrument 2135); abrasion and reglaze; abrasion and polishing (diamond rotary instrument 2135F, 2135 FF, and polishing devices); and polishing. The topography of the crowns was examined by scanning electron microscopy, and roughness was measured. A compressive load (0.5 mm/min) was applied by a piston to the center of the lingual cusp until fracture. The fracture load was recorded and data were statistically analyzed by ANOVA and the Tukey HSD test (α=.05). Fractured crowns were examined to determine the fracture origin. Polishing and/or reglazing resulted in lower roughness than for the abraded group (P<.05), which did not affect the fracture loads (P=.696). Catastrophic fracture with origin at the intaglio surface was the mode of failure for all the crowns. The experiment design successfully submitted the crowns to a clinical stress state, resulting in a clinically relevant failure. Reglazing or polishing were effective in reducing surface defects. Surface treatments had no effect on the immediate catastrophic failure of LDS crowns. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
From eugenics to lysenkoism: the evolution of Stanisław Skowron.
Dejong-Lambert, William
2009-01-01
This article describes the relationship between Polish geneticist Stanisław Skowron's views on eugenics during the interwar period, his experiences in Nazi concentration camps during World War II, and his response to Trofim D. Lysenko's ban on genetic research in Soviet-allied states after 1948. Skowron was educated at the Jagiellonian University in Krakow and received funding from the Rockefeller Foundation to study in the United States, Italy, Denmark, and Great Britain from 1924 to 1926. His exposure to research being conducted outside of Poland made him an important figure in Polish genetics. During this time Skowron also began to believe that an understanding of biological principles of heredity could play an important role in improving Polish society and became a supporter of eugenics. In 1939 he was arrested along with other faculty members at the Jagiellonian and sent to Sachsenhausen and Dachau. In 1947 he published the first book updating Polish biologists on recent developments in genetics; however, after learning of the outcome of the 1948 session of the Lenin All-Union Academy of Agricultural Sciences in Moscow, Skowron emerged as on of the most vocal advocates for Michurinism. I argue that Skowron's conversion to Lysenkoism was motivated by more than fear or opportunism, and is better understood as the product of his need to rationalize his own support for a theory he could not possibly have believed was correct.
Luchinskaya, Darya; Du, Rong; Owens, David M; Tarnow, Dennis; Bittner, Nurit
2017-02-01
The aim of this in vitro study was to investigate the ability of epithelial cells to attach to or proliferate on various mechanical or chemical surface treatments of an implant provisional material. Polyethyl methacrylate discs 10 mm in diameter and ∼0.2 to 0.75 mm in width were used in the study. Experimental discs were treated with either a mechanical (pumice, varnish for shine, or high polishing) or a chemical agent (alcohol, chlorhexidine, or steam) to provide cleaning and/or polishing. Using primary human epidermal keratinocytes, experiments were performed to test the adhesion or proliferation of cells on the discs with various surface treatments. Scanning electron microscope analysis, rhodamine staining, and cell counting using a hemocytometer corroborated all findings and illustrated that the highest cell adhesion was found to be in the smooth surface treatment groups and the poorest adhesion was found to be in the rough surface groups and chemical treatment group. Within the limitations of this study, the following clinical protocol is recommended for finishing, polishing, and disinfecting implant provisional restorations: coarse, medium, fine pumice → high polishing (if desired) → steam. It is recommended to avoid applying varnish in the perimucosal area near the epithelium. This study could establish the most appropriate way to handle provisional restorations in the peri-implant sulcus for improved soft tissue health, esthetics, and long-term stability.
Super-polishing of Zerodur aspheres by means of conventional polishing technology
NASA Astrophysics Data System (ADS)
Polak, Jaroslav; Klepetková, Eva; Pošmourný, Josef; Šulc, Miroslav; Procháska, František; Tomka, David; Matoušek, Ondřej; Poláková, Ivana; Šubert, Eduard
2015-01-01
This paper describes a quest to find simple technique to superpolish Zerodur asphere (55μm departure from best fit sphere) that could be employed on old fashion way 1-excenter optical polishing machine. The work focuses on selection of polishing technology, study of different polishing slurries and optimization of polishing setup. It is demonstrated that either by use of fine colloidal CeO2 slurry or by use of bowl-feed polishing setup with CeO2 charged pitch we could reach 0.4nm RMS roughness while removing <30nm of surface layer. This technique, although not optimized, was successfully used to improve surface roughness on already prepolished Zerodur aspheres without necessity to involve sophisticated super-polishing technology and highly trained manpower.
NASA Astrophysics Data System (ADS)
Rosiek, Roman; Sajka, Mirosława; Ohno, Eizo; Shimojo, Atsushi; Iwata, Michiru; Wcisło, Dariusz
2017-01-01
The paper presents the initial results of a comparative Polish-Japanese study. The research was conducted at the Department of Mathematics, Physics and Technical Science at the Pedagogical University of Cracow and at the University of Hokkaido. The participants of the study were university students of humanistic courses. The research concerns the comparison of the respondents' knowledge and understanding of the concept of force in mechanics and their ways of solving problems in the field of a basic mechanics course. A special theoretical tool was used. It was the standardized, international test diagnosing the understanding of the concept of force - the so-called "Force Concept Inventory" (FCI), in its official Polish and Japanese translations. The eye-tracking method was combined with structured interviews and discussions with all the respondents.
BastaniNejad, Mahzad; Elmustafa, Abdelmageed A.; Forman, Eric; ...
2015-07-01
DC high voltage photoelectron guns are used to produce polarized electron beams for accelerator-based nuclear and high-energy physics research. Low-level field emission (~nA) from the cathode electrode degrades the vacuum within the photogun and reduces the photoelectron yield of the delicate GaAs-based photocathode used to produce the electron beams. High-level field emission (>μA) can cause significant damage the photogun. To minimize field emission, stainless steel electrodes are typically diamond-paste polished, a labor-intensive process often yielding field emission performance with a high degree of variability, sample to sample. As an alternative approach and as comparative study, the performance of electrodes electropolishedmore » by conventional commercially available methods is presented. Our observations indicate the electropolished electrodes exhibited less field emission upon the initial application of high voltage, but showed less improvement with gas conditioning compared to the diamond-paste polished electrodes. In contrast, the diamond-paste polished electrodes responded favorably to gas conditioning, and ultimately reached higher voltages and field strengths without field emission, compared to electrodes that were only electropolished. The best performing electrode was one that was both diamond-paste polished and electropolished, reaching a field strength of 18.7 MV/m while generating less than 100 pA of field emission. The speculate that the combined processes were the most effective at reducing both large and small scale topography. However, surface science evaluation indicates topography cannot be the only relevant parameter when it comes to predicting field emission performance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
BastaniNejad, Mahzad; Elmustafa, Abdelmageed A.; Forman, Eric
DC high voltage photoelectron guns are used to produce polarized electron beams for accelerator-based nuclear and high-energy physics research. Low-level field emission (~nA) from the cathode electrode degrades the vacuum within the photogun and reduces the photoelectron yield of the delicate GaAs-based photocathode used to produce the electron beams. High-level field emission (>μA) can cause significant damage the photogun. To minimize field emission, stainless steel electrodes are typically diamond-paste polished, a labor-intensive process often yielding field emission performance with a high degree of variability, sample to sample. As an alternative approach and as comparative study, the performance of electrodes electropolishedmore » by conventional commercially available methods is presented. Our observations indicate the electropolished electrodes exhibited less field emission upon the initial application of high voltage, but showed less improvement with gas conditioning compared to the diamond-paste polished electrodes. In contrast, the diamond-paste polished electrodes responded favorably to gas conditioning, and ultimately reached higher voltages and field strengths without field emission, compared to electrodes that were only electropolished. The best performing electrode was one that was both diamond-paste polished and electropolished, reaching a field strength of 18.7 MV/m while generating less than 100 pA of field emission. The speculate that the combined processes were the most effective at reducing both large and small scale topography. However, surface science evaluation indicates topography cannot be the only relevant parameter when it comes to predicting field emission performance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
BastaniNejad, Mahzad, E-mail: Mahhzad@gmail.com; Elmustafa, Abdelmageed A.; Forman, Eric
DC high voltage photoelectron guns are used to produce polarized electron beams for accelerator-based nuclear and high-energy physics research. Low-level field emission (∼nA) from the cathode electrode degrades the vacuum within the photogun and reduces the photoelectron yield of the delicate GaAs-based photocathode used to produce the electron beams. High-level field emission (>μA) can cause significant damage the photogun. To minimize field emission, stainless steel electrodes are typically diamond-paste polished, a labor-intensive process often yielding field emission performance with a high degree of variability, sample to sample. As an alternative approach and as comparative study, the performance of electrodes electropolishedmore » by conventional commercially available methods is presented. Our observations indicate the electropolished electrodes exhibited less field emission upon the initial application of high voltage, but showed less improvement with gas conditioning compared to the diamond-paste polished electrodes. In contrast, the diamond-paste polished electrodes responded favorably to gas conditioning, and ultimately reached higher voltages and field strengths without field emission, compared to electrodes that were only electropolished. The best performing electrode was one that was both diamond-paste polished and electropolished, reaching a field strength of 18.7 MV/m while generating less than 100 pA of field emission. The authors speculate that the combined processes were the most effective at reducing both large and small scale topography. However, surface science evaluation indicates topography cannot be the only relevant parameter when it comes to predicting field emission performance.« less
[Surface characteristics of the acrylic resins according to the polishing methods].
Vitalariu, Anca Mihaela; Lazăr, Lenuţa; Buruiană, Tinca; Diaconu, Diana; Tatarciuc, Monica Silvia
2011-01-01
The objective of this study was to evaluate the effect of the polishing technique and glazing on the porosity of the dental resins. The studied resins were: Castapress/Vertex, Prothyl Hot/Zermack, Rapid Simplified/Vertex, Duracryl Plus/Spofa Dental, Vertex-Soft/Vertex, Superacryl Plus/Spofa Dental. Thirty specimens, five for every resin, of 50/25/2 cm in size were done. One surface of each sample was polished with extrahard tungsten carbide burs, the other surface being polished with extrahard extrafine and diamond burs. The final polishing was done using a conventional method: pumice, water and lathe bristle brush for 90 seconds, 1500 rpm and soft leather polishing wheel for 90 seconds, 3000 rpm. Twenty surfaces were glazed after polishing with Glaze/Bosworth. Vertex Soft specimens were not polished because this is a resilient material. Surface porosity of the acrylic resin specimens was measured by optical microscopy. The lowest porosity was obtained by conventional polishing combined with glazing techniques. No differences between glazed and non/glazed self-curing resin specimens were noticed, but there were differences between self-curing and heat-curing resins. Conventional lathe polishing method is an effective and reliable technique for polishing dental resins. Specimens of self-curing resin had a higher porosity than heat curing resin following the same surface treatment. Higher surface smoothness was obtained by conventional lathe polishing completed by glazing.
Chemistry and Formation of the Beilby Layer During Polishing of Fused Silica Glass
Suratwala, Tayyab; Steele, William; Wong, Lana; ...
2015-05-19
The chemical characteristics and the proposed formation mechanisms of the modified surface layer (called the Beilby layer) on polished fused silica glasses are described. Fused silica glass samples were polished using different slurries, polyurethane pads, and at different rotation rates. The concentration profiles of several key contaminants, such as Ce, K, and H, were measured in the near surface layer of the polished samples using Secondary Ion Mass Spectroscopy (SIMS). The penetration of K, originating from KOH used for pH control during polishing, decreased with increase in polishing material removal rate. In contrast, penetration of the Ce and H increasedmore » with increase in polishing removal rate. In addition, Ce penetration was largely independent of the other polishing parameters (e.g., particle size distribution and the properties of the polishing pad). The resulting K concentration depth profiles are described using a two-step diffusion process: (1) steady-state moving boundary diffusion (due to material removal during polishing) followed by (2) simple diffusion during ambient postpolishing storage. Using known alkali metal diffusion coefficients in fused silica glass, this diffusion model predicts concentration profiles that are consistent with the measured data at various polishing material removal rates. On the other hand, the observed Ce profiles are inconsistent with diffusion based transport. Rather we propose that Ce penetration is governed by the ratio of Ce–O–Si and Si–O–Si hydrolysis rates; where this ratio increases with interface temperature (which increases with polishing material removal rate) resulting in greater Ce penetration into the Beilby layer. Calculated Ce surface concentrations using this mechanism are in good agreement to the observed change in measured Ce surface concentrations with polishing material removal rate. In conclusion, these new insights into the chemistry of the Beilby layer, combined together with details of the single particle removal function during polishing, are used to develop a more detailed and quantitative picture of the polishing process and the formation of the Beilby layer.« less
NASA Astrophysics Data System (ADS)
Basirin, Hammadi bin Mohd; Nawi, Ismail bin Haji Mohd
2017-04-01
This research is an approach to improve the surface roughness for acrylic door panel by using polishing process. The polishing process involve is sanding process by 3 types of sand paper. The sanding process used to improve the surface roughness by using the different grit sizes of sand paper. The experiment was done by using two types of material s, that is plywood and medium density board (MDF). These two materials are the main materials in producing the arcrylic door panel. The surface roughness of these two materials affects the qualities and quantities of the acrylic door panel. The surface structure was measured by using Optical Microscope and Scanning Electron Microscope (SEM) and the surface roughness was measured by using Mitutoyo surfest SJ 400 Tester. Results indicates that using the different types of grit are influence the surface roughness of the material. When the higher types of grit sizes had been used, the average roughness of the surface are decrease. In summary, a good surface roughness condition produced when using the higher types of grit sizes sand paper.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kawagoe, Yoshiaki; Isono, Susumu; Takeno, Takanori
2014-12-09
It has been reported that the friction between a partially polished diamond-coated surface and a metal surface was drastically reduced to zero when they are slid at a few m/s. Since the sliding was noiseless, it seems that the diamond-coated surface was levitated over the counter surface and the sliding mechanism was the gas film lubrication. Recently, the mechanism of levitation of a slider with a micro/nanoscale surface structure on a rotating disk was theoretically clarified [S. Yonemura et al., Tribol. Lett., (2014), doi:10.1007/s11249-014-0368-2]. Probably, the partially polished diamond-coated surface may be levitated by high gas pressure generated by themore » micro/nanoscale surface structure on it. In this study, in order to verify our deduction, we performed numerical simulations of sliding of partially polished diamond-coated surface by reproducing its complicated surface structure using the data measured by an atomic force microscope (AFM). As a result, we obtained the lift force which is large enough to levitate the slider used in the experiment.« less
NASA Astrophysics Data System (ADS)
He, Qiuwei; Lv, Xingming; Wang, Xin; Qu, Xingtian; Zhao, Ji
2017-01-01
Blade is the key component in the energy power equipment of turbine, aircraft engines and so on. Researches on the process and equipment for blade finishing become one of important and difficult point. To control precisely tool system of developed hybrid grinding and polishing machine tool for blade finishing, the tool system with changeable wheel for belt polishing is analyzed in this paper. Firstly, the belt length and wrap angle of each wheel in different position of tension wheel swing angle in the process of changing wheel is analyzed. The reasonable belt length is calculated by using MATLAB, and relationships between wrap angle of each wheel and cylinder expansion amount of contact wheel are obtained. Then, the control system for changeable wheel tool structure is developed. Lastly, the surface roughness of blade finishing is verified by experiments. Theoretical analysis and experimental results show that reasonable belt length and wheel wrap angle can be obtained by proposed analysis method, the changeable wheel tool system can be controlled precisely, and the surface roughness of blade after grinding meets the design requirements.
Carey, Manus; Jiujin, Xiao; Gomes Farias, Júlia; Meharg, Andrew A.
2015-01-01
A novel way of cooking rice to maximize the removal of the carcinogen inorganic arsenic (Asi) is presented here. In conventional rice cooking water and grain are in continuous contact, and it is known that the larger the water:rice cooking ratio, the more Asi removed by cooking, suggesting that the Asi in the grain is mobile in water. Experiments were designed where rice is cooked in a continual stream of percolating near boiling water, either low in Asi, or Asi free. This has the advantage of not only exposing grain to large volumes of cooking water, but also physically removes any Asi leached from the grain into the water receiving vessel. The relationship between cooking water volume and Asi removal in conventional rice cooking was demonstrated for the rice types under study. At a water-to-rice cooking ratio of 12:1, 57±5% of Asi could be removed, average of 6 wholegrain and 6 polished rice samples. Two types of percolating technology were tested, one where the cooking water was recycled through condensing boiling water steam and passing the freshly distilled hot water through the grain in a laboratory setting, and one where tap water was used to cook the rice held in an off-the-shelf coffee percolator in a domestic setting. Both approaches proved highly effective in removing Asi from the cooking rice, with up to 85% of Asi removed from individual rice types. For the recycled water experiment 59±8% and 69±10% of Asi was removed, on average, compared to uncooked rice for polished (n=27) and wholegrain (n=13) rice, respectively. For coffee percolation there was no difference between wholegrain and polished rice, and the effectiveness of Asi removal was 49±7% across 6 wholegrain and 6 polished rice samples. The manuscript explores the potential applications and further optimization of this percolating cooking water, high Asi removal, discovery. PMID:26200355
Carey, Manus; Jiujin, Xiao; Gomes Farias, Júlia; Meharg, Andrew A
2015-01-01
A novel way of cooking rice to maximize the removal of the carcinogen inorganic arsenic (Asi) is presented here. In conventional rice cooking water and grain are in continuous contact, and it is known that the larger the water:rice cooking ratio, the more Asi removed by cooking, suggesting that the Asi in the grain is mobile in water. Experiments were designed where rice is cooked in a continual stream of percolating near boiling water, either low in Asi, or Asi free. This has the advantage of not only exposing grain to large volumes of cooking water, but also physically removes any Asi leached from the grain into the water receiving vessel. The relationship between cooking water volume and Asi removal in conventional rice cooking was demonstrated for the rice types under study. At a water-to-rice cooking ratio of 12:1, 57±5% of Asi could be removed, average of 6 wholegrain and 6 polished rice samples. Two types of percolating technology were tested, one where the cooking water was recycled through condensing boiling water steam and passing the freshly distilled hot water through the grain in a laboratory setting, and one where tap water was used to cook the rice held in an off-the-shelf coffee percolator in a domestic setting. Both approaches proved highly effective in removing Asi from the cooking rice, with up to 85% of Asi removed from individual rice types. For the recycled water experiment 59±8% and 69±10% of Asi was removed, on average, compared to uncooked rice for polished (n=27) and wholegrain (n=13) rice, respectively. For coffee percolation there was no difference between wholegrain and polished rice, and the effectiveness of Asi removal was 49±7% across 6 wholegrain and 6 polished rice samples. The manuscript explores the potential applications and further optimization of this percolating cooking water, high Asi removal, discovery.
A Force-Controllable Macro-Micro Manipulator and its Application to Medical Robotics
NASA Technical Reports Server (NTRS)
Marzwell, Neville I.; Uecker, Darrin R.; Wang, Yulun
1993-01-01
This paper describes an 8-degrees-of-freedom macro-micro robot. This robot is capable of performing tasks that require accurate force control, such as polishing, finishing, grinding, deburring, and cleaning. The design of the macro-micro mechanism, the control algorithms, and the hardware/sofware implemtation of the algotithms are described in this paper. Initial experimental results are reported.
Heintze, Siegward Dietmar; Forjanic, Monika
2008-10-01
To evaluate the effect of the multiple-use of a three-step rubber-based polishing system on the polishing performance with and without a disinfection/sterilization protocol with prolonged disinfection (overnight). The three-step polishing system Astropol was applied under standardized contact pressure of 2 N on 320 grit pre-roughened flat composite specimens of Tetric EvoCeram for 10 seconds (F and P disc) and 30 seconds (HP disc) respectively. After each polishing step, the surface gloss and roughness were measured with a glossmeter and an optical sensor (FRT MicroProf), respectively. Material loss of the composite specimens and polishing instruments were measured after each step with a high precision digital scale. For all four variables (surface gloss, surface roughness, composite loss, loss of rubber material) the mean percentage of change compared to the reference was calculated. Already after the first use, the instruments which were used without disinfection or sterilization demonstrated a statistically significantly reduced polishing performance in all polishing steps compared to the reference (new polishing system) (t-test, P < 0.05). In addition, this loss in performance further increased with the second and third re-use. Especially the third component (Astropol HP) was affected by performance loss. By contrast, the multiple-use of the instruments which were subjected to prolonged disinfection did not result in a reduced polishing performance. For the P disc, a statistically significant improvement of the polishing performance could be observed throughout almost all multiple-use sessions (ANOVA, P < 0.05). The improved polishing performance was, however, accompanied by an increased loss of the silicone rubber material of the P and F polishing discs; the HP discs were not affected by this loss. Furthermore, particles of the rubber material also adhered to the composite. The polishing performance of the discs which were only subjected to the sterilization process was not statistically significantly different to the polishing performance of the control group in terms of surface roughness; but the surface gloss was worse than that of the control group. No loss of rubber material or adherence to the composite was observed in this group.
Health Information in Polish (polski)
... Tools You Are Here: Home → Multiple Languages → Polish (polski) URL of this page: https://medlineplus.gov/languages/polish.html Health Information in Polish (polski) To use the sharing features on this page, ...
Dahlin, Jakob; Berne, Berit; Dunér, Kari; Hosseiny, Sara; Matura, Mihály; Nyman, Gunnar; Tammela, Monica; Isaksson, Marléne
2016-09-01
Ultraviolet (UV)-curing nail polishes based on acrylates or methacrylates are currently also available for non-professional use. The Swedish Medical Products Agency recently prohibited one brand of UV-curing polish, because several consumers reported undesirable effects after using it. To investigate whether consumers with undesirable effects after using the UV-curing nail polish that was later prohibited were contact allergic to the polish and its individual ingredients. Eight patients who had reported severe skin reactions after the use of the UV-curing polish were patch tested with two coatings of the nail polish and its ingredients at five dermatology departments in Sweden. All patients tested except one showed contact allergic reactions to one or several of the acrylate-based or methacrylate-based ingredients in the nail polish. The non-professional use of UV-curing nail polishes poses a risk of sensitization from acrylates and methacrylates. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
PROBLEMS OF THE OPTICAL MODEL FOR DEUTERONS. I. PARAMETERS OF THE OPTICAL POTENTIAL (in Polish)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grotowski, K.
1963-01-01
S>Problems concerning the optical model are discussed. Some special properties of deuterons as projectiles influence the optical model describing their interaction with nuclei. Several experiments were performed to obtain parameters of the optical model potential. (auth)
Newborn screening for cystic fibrosis: Polish 4 years' experience with CFTR sequencing strategy.
Sobczyńska-Tomaszewska, Agnieszka; Ołtarzewski, Mariusz; Czerska, Kamila; Wertheim-Tysarowska, Katarzyna; Sands, Dorota; Walkowiak, Jarosław; Bal, Jerzy; Mazurczak, Tadeusz
2013-04-01
Newborn screening for cystic fibrosis (NBS CF) in Poland was started in September 2006. Summary from 4 years' experience is presented in this study. The immunoreactive trypsin/DNA sequencing strategy was implemented. The group of 1,212,487 newborns were screened for cystic fibrosis during the programme. We identified a total of 221 CF cases during this period, including, 4 CF cases were reported to be omitted by NBS CF. Disease incidence in Poland based on the programme results was estimated as 1/4394 and carrier frequency as 1/33. The frequency of the F508del was similar (62%) to population data previously reported. This strategy allowed us to identify 29 affected infants with rare genotypes. The frequency of some mutations (eg, 2184insA, K710X) was assessed in Poland for the first time. Thus, sequencing assay seems to be accurate method for screening programme using blood spots in the Polish population.
The EUV-observatory TESIS on board Coronas-Photon: scientific goals and initial plan of observations
NASA Astrophysics Data System (ADS)
Bogachev, Sergey
The TESIS a EUV-observatory for solar research from space will be launched in 2008 September on board the satellite Coronas-Photon from cosmodrome Plesetsk. TESIS is a project of Lebedev Physical Institute of Russian Academy of Science with contribution from Space Research Center of Polish Academy of Science (the spectrometer SphinX). The experiment will focus on quasi-monochromatic imaging of the Sun and XUV spectroscopy of solar plasma. The scientific payload of TESIS contains five instruments: (1) Bragg crystal spectroheliometer for Sun monochromatic imaging in the line MgXII 8.42 A, (2) the normal-incidence Herschelian EUV telescopes with a resolution of 1.7 arc sec operated in lines FeXXII 133 A, FeIX 171 A and HeII 304 A, (3) the EUV imaging spectrometer, (4) the wide-field Ritchey-Chretien coronograph and (5) the X-ray spectrometer SphinX. The TESIS will focus on coordinated study of solar activity from the transition region to the outer corona up to 4 solar radii in wide temperature range from 5*104 to 2*107 K. We describe the scientific goals of the TESIS and its initial plan of observations.
Shao, Yu; Wang, Ying; Cao, Shaoqing; Huang, Yijian; Zhang, Longfei; Zhang, Feng; Liao, Changrui; Wang, Yiping
2018-06-25
A surface plasmon resonance (SPR) sensor based on a side-polished single mode fiber coated with polyvinyl alcohol (PVA) is demonstrated for relative humidity (RH) sensing. The SPR sensor exhibits a resonant dip in the transmission spectrum in ambient air after PVA film coating, and the resonant wavelength shifts to longer wavelengths as the thickness of the PVA film increases. When RH changes, the resonant dip of the sensor with different film-thicknesses exhibits interesting characteristics for optical spectrum evolution. For sensors with initial wavelengths between 550 nm and 750 nm, the resonant dip shifts to longer wavelengths with increasing RH. The averaged sensitivity increases firstly and then drops, and shows a maximal sensitivity of 1.01 nm/RH%. Once the initial wavelength of the SPR sensor exceeds 850 nm, an inflection point of the resonant wavelength shift can be observed with RH increasing, and the resonant dip shifts to shorter wavelengths for RH values exceeding this point, and sensitivity as high as −4.97 nm/RH% can be obtained in the experiment. The sensor is expected to have potential applications in highly sensitive and cost effective humidity sensing.
Perceptions of and Attitudes towards Regional Varieties of Polish: Views from Two Polish Provinces
ERIC Educational Resources Information Center
Milobog, Magdalena; Garrett, Peter
2011-01-01
This paper reports a study of perceptions and attitudes relating to regional varieties of Polish. The methodology followed folk linguistic approaches to attitudes research. Respondents in two Polish provinces were asked to draw on a map of Poland where they thought the main regional varieties of Polish were spoken, and then to name and…
Madhyastha, Prashanthi Sampath; Hegde, Shreya; Srikant, N; Kotian, Ravindra; Iyer, Srividhya Sriraman
2017-01-01
Surface roughness associated with improper finishing/polishing of restorations can result in plaque accumulation, gingival irritation, surface staining, and poor esthetic of restored teeth. The study aimed to evaluate the efficiency of various finishing and polishing systems and time using various procedures on surface roughness of some esthetic restorative materials. In this in vitro study, samples of two composite materials, compomer and glass ionomer cement (GIC) materials, were fabricated. Finishing and polishing were done immediately ( n = 40) and after 1 week ( n = 40) using four systems (diamond bur + soflex discs; diamond bur + Astropol polishing brush; tungsten carbide bur + soflex discs; tungsten carbide bur + Astropol polishing brush). Surface roughness was measured using surface profilometer. Data were statistically analyzed by t -test (for each material and time period) and one-way analysis of variance followed by Tukey's post hoc (for finishing and polishing systems) at a significant level of P < 0.05. Analysis of time period, irrespective of finishing and polishing system showed that Ra values were greater ( P < 0.05) in delayed polishing in GIC > Z100 > Filtek P90 > Dyract AP, suggesting immediate polishing is better. Among the materials, Filtek P90 had the least Ra values indicating the smoothest surface among all materials, followed by Z100, Dyract AP, and GIC. Comparison of polishing and finishing systems irrespective of materials showed that Ra values were lower ( P > 0.05) in diamond + Astropol combination whereas diamond + soflex had the greatest Ra values. It might be concluded that: (i) Filtek P90 showed least Ra values followed by < Z100 < Dyract < GIC; (ii) immediate (24 h) finishing/polishing of materials is better than delayed; and (iii) among all these polishing systems, diamond bur-Astropol and Astrobrush showed good surface finish.
Polish universal neonatal hearing screening program-4-year experience (2003-2006).
Szyfter, Witold; Wróbel, Maciej; Radziszewska-Konopka, Marzanna; Szyfter-Harris, Joanna; Karlik, Michał
2008-12-01
The aim of this paper is to share our experience and observations in running the Universal Neonatal Hearing Screening Program on a national level, present results and indicate some problems that have arisen during these 4 years. Polish Universal Neonatal Hearing Screening Program started back in 2002 in all neonatal units in Poland. Implemented testing methods consisted of test of transient evoked otoacoustic emission (TEOAE) performed in all new born children in their first 2-3 days of life and auditory brainstem response testing (ABR) conducted on children, who did not meet the TEOAE pass criteria. Additional questionnaire registered information on ototoxic drugs and family history of hearing impairment in every newborn. Diagnosed children were further referred for treatment and rehabilitation. After 4 years of running the program (between 2003 and 2006) a total number of 1,392,427 children were screened for hearing impairment, what stands for 96.3% of all delivered babies, registered in Poland. The screening program enabled to identify and refer for further treatment 2485 children with various types of hearing loss, 312 with profound (0.02% of population) and 145 with severe sensorineural hearing loss (0.11% of population). Our results indicate the accuracy of newborn hearing screening which remain an issue. Although improvement is needed in both intervention systems and diagnostic follow-up of hospitals, the Polish Universal Neonatal Hearing Program fully has achieved the main goal, the identification and treatment of hearing impaired children.
Yazici, A Ruya; Tuncer, Duygu; Antonson, Sibel; Onen, Alev; Kilinc, Evren
2010-01-01
The aim of this study was to investigate the effect of delayed finishing/polishing on the surface roughness, hardness and gloss of tooth-coloured restorative materials. Four different tooth-coloured restoratives: a flowable resin composite- Tetric Flow, a hybrid resin composite- Venus, a nanohybrid resin composite- Grandio, and a polyacid modified resin composite- Dyract Extra were used. 30 specimens were made for each material and randomly assigned into three groups. The first group was finished/polished immediately and the second group was finished/polished after 24 hours. The remaining 10 specimens served as control. The surface roughness of each sample was recorded using a laser profilometer. Gloss measurements were performed using a small-area glossmeter. Vickers microhardness measurements were performed from three locations on each specimen surface under 100g load and 10s dwell time. Data for surface roughness and hardness were analyzed by Kruskal Wallis test and data for gloss were subjected to one-way ANOVA and Tukey test (P <.05). The smoothest surfaces were obtained under Mylar strip for all materials. While there were no significant differences in surface roughness of immediate and delayed finished/polished Dyract Extra samples, immediately finished/polished Venus and Grandio samples showed significantly higher roughness than the delayed polished samples (P <.05). In Tetric Flow samples, immediately finishing/polishing provided smoother surface than delayed finishing/polishing (P <.05). The highest gloss values were recorded under Mylar strip for all materials. While delayed finishing/polishing resulted in a significantly higher gloss compared to immediate finishing/polishing in Venus samples (P <.05), no differences were observed between delayed or immediate finishing/polishing for the other materials (P>.05). The lowest hardness values were found under Mylar strip. Delayed finishing/polishing significantly increased the hardness of all materials. The effect of delayed finishing/polishing on surface roughness, gloss and hardness appears to be material dependent.
Heimer, Sina; Schmidlin, Patrick R; Roos, Malgorzata; Stawarczyk, Bogna
2017-03-01
Polyetheretherketone (PEEK) can be used as a framework material for fixed dental prostheses. However, information about laboratory and chairside polishing methods is still scarce. The purpose of this in vitro study was to determine the effects of laboratory and chairside polishing methods on the surface roughness (SR) and surface free energy (SFE) of PEEK, an autopolymerizing poly(methyl methacrylate), and a veneering composite resin. For each of the 3 materials, 80 specimens were prepared (N=240) and divided into 7 polishing groups and 1 control group (n=10). The 7 groups were split into 4 laboratory protocols: polishing paste (Abraso), a second polishing paste (Opal L), silicone polisher (Ceragum), and diamond grinder (Diagen-Turbo grinder). The other 3 groups were chairside protocols: rainbow technique (Super-Snap kit), polishing paste (Prisma gloss), and a polishing system (Enhance finishing). Machine polishing with SiC P4000 served as the control treatment. The protocols' average SRs and SFEs were measured, and their surface topographies were evaluated with scanning electron microscopy (SEM). The logarithmically transformed data were analyzed using covariance analysis, 2-way and 1-way ANOVA, and partial correlation (α=.05). The polishing protocol exerted the highest influence on SR and SFE values (P<.001; SR: partial eta squared η P 2 =.970; SFE: η P 2 =.450), followed by material group (P<.001, SR: η P 2 =.319; SFE: η P 2 =.429). The interaction effect of the binary combinations of the 2 independent parameters (polishing protocol and material group) was also significant (P<.001, SR: η P 2 =.681; SFE: η P 2 =.365). Chairside methods presented lower SR values than laboratory methods, and specimens polished using the 2-body mode showed higher SR than did specimens polished using the 3-body mode. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Schinhaerl, Markus; Schneider, Florian; Rascher, Rolf; Vogt, Christian; Sperber, Peter
2010-10-01
Magnetorheological finishing is a typical commercial application of a computer-controlled polishing process in the manufacturing of precision optical surfaces. Precise knowledge of the material removal characteristic of the polishing tool (influence function) is essential for controlling the material removal on the workpiece surface by the dwell time method. Results from the testing series with magnetorheological finishing have shown that a deviation of only 5% between the actual material removal characteristic of the polishing tool and that represented by the influence function caused a considerable reduction in the polishing quality. The paper discusses reasons for inaccuracies in the influence function and the effects on the polishing quality. The generic results of this research serve for the development of improved polishing strategies, and may be used in alternative applications of computer-controlled polishing processes that quantify the material removal characteristic by influence functions.
[Mental health of Polish immigrants compared to that of the Polish and German populations].
Morawa, Eva; Senf, Wolfgang; Erim, Yesim
2013-01-01
This survey examines the mental health of immigrants of Polish origin compared to samples from the Polish and German populations. In a sample of 513 subjects (261 persons with Polish migration background and 252 autochthone Poles) depression (BDI), anxiety (BAI), and somatic complaints (GBB-24) were measured. Immigrants of Polish origin showed a significantly higher level of anxiety as well as somatic complaints but only a tendency toward higher depressiveness than the German normvalue, but not than that of the native Poles. Female immigrants showed an overall higher number of symptoms in the three domains in question compared to German women and - except for depressiveness - also compared to male immigrants. Persons with a Polish migration background present levels of mental distress higher than the general German population, but similar to the population of their country of origin. Further research is needed to clarify the special structure of the mental morbidity in Polish immigrants.
Ziętkiewicz, Ewa; Rutkiewicz, Ewa; Pogorzelski, Andrzej; Klimek, Barbara; Voelkel, Katarzyna; Witt, Michał
2014-01-01
Cystic fibrosis (CF) is caused by mutations in the cystic fibrosis transmembrane regulator gene (CFTR). In light of the strong allelic heterogeneity and regional specificity of the mutation spectrum, the strategy of molecular diagnostics and counseling in CF requires genetic tests to reflect the frequency profile characteristic for a given population. The goal of the study was to provide an updated comprehensive estimation of the distribution of CFTR mutations in Polish CF patients and to assess the effectiveness of INNOLiPA_CFTR tests in Polish population. The analyzed cohort consisted of 738 patients with the clinically confirmed CF diagnosis, prescreened for molecular defects using INNOLiPA_CFTR panels from Innogenetics. A combined efficiency of INNOLiPA CFTR_19 and CFTR_17_TnUpdate tests was 75.5%; both mutations were detected in 68.2%, and one mutation in 14.8% of the affected individuals. The group composed of all the patients with only one or with no mutation detected (109 and 126 individuals, respectively) was analyzed further using a mutation screening approach, i.e. SSCP/HD (single strand conformational polymorphism/heteroduplex) analysis of PCR products followed by sequencing of the coding sequence. As a result, 53 more mutations were found in 97 patients. The overall efficiency of the CF allele detection was 82.5% (7.0% increase compared to INNOLiPA tests alone). The distribution of the most frequent mutations in Poland was assessed. Most of the mutations repetitively found in Polish patients had been previously described in other European populations. The most frequent mutated allele, F508del, represented 54.5% of Polish CF chromosomes. Another eight mutations had frequencies over 1%, 24 had frequencies between 1 and 0.1%; c.2052-2053insA and c.3468+2_3468+3insT were the most frequent non-INNOLiPA mutations. Mutation distribution described herein is also relevant to the Polish diaspora. Our study also demonstrates that the reported efficiency of mutation detection strongly depends on the diagnostic experience of referring health centers. PMID:24586523
Ziętkiewicz, Ewa; Rutkiewicz, Ewa; Pogorzelski, Andrzej; Klimek, Barbara; Voelkel, Katarzyna; Witt, Michał
2014-01-01
Cystic fibrosis (CF) is caused by mutations in the cystic fibrosis transmembrane regulator gene (CFTR). In light of the strong allelic heterogeneity and regional specificity of the mutation spectrum, the strategy of molecular diagnostics and counseling in CF requires genetic tests to reflect the frequency profile characteristic for a given population. The goal of the study was to provide an updated comprehensive estimation of the distribution of CFTR mutations in Polish CF patients and to assess the effectiveness of INNOLiPA_CFTR tests in Polish population. The analyzed cohort consisted of 738 patients with the clinically confirmed CF diagnosis, prescreened for molecular defects using INNOLiPA_CFTR panels from Innogenetics. A combined efficiency of INNOLiPA CFTR_19 and CFTR_17_TnUpdate tests was 75.5%; both mutations were detected in 68.2%, and one mutation in 14.8% of the affected individuals. The group composed of all the patients with only one or with no mutation detected (109 and 126 individuals, respectively) was analyzed further using a mutation screening approach, i.e. SSCP/HD (single strand conformational polymorphism/heteroduplex) analysis of PCR products followed by sequencing of the coding sequence. As a result, 53 more mutations were found in 97 patients. The overall efficiency of the CF allele detection was 82.5% (7.0% increase compared to INNOLiPA tests alone). The distribution of the most frequent mutations in Poland was assessed. Most of the mutations repetitively found in Polish patients had been previously described in other European populations. The most frequent mutated allele, F508del, represented 54.5% of Polish CF chromosomes. Another eight mutations had frequencies over 1%, 24 had frequencies between 1 and 0.1%; c.2052-2053insA and c.3468+2_3468+3insT were the most frequent non-INNOLiPA mutations. Mutation distribution described herein is also relevant to the Polish diaspora. Our study also demonstrates that the reported efficiency of mutation detection strongly depends on the diagnostic experience of referring health centers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grotowski, K.
1963-01-01
An experiment for determination of the parameters of the optical potential for deuterons is presented. Total reaction cross sections for the interaction of deuterons with nuclei were determined by evaluating the cross sections for the emission of charged particles and neutrons. The angular distributions for the elastic scattering of deuterons were also measured. (auth)
Sizing Up Objects: The Effect of Diminutive Forms on Positive Mood, Value, and Size Judgments
Parzuchowski, Michał; Bocian, Konrad; Gygax, Pascal
2016-01-01
Language (e.g., structure, morphology, and wording) can direct our attention toward the specific properties of an object, in turn influencing the mental representation of that same object. In this paper, we examined this idea by focusing on a particular linguistic form of diminution used in many languages (e.g., in Polish, Spanish, and Portuguese) to refer to an object as being “smaller.” Interestingly, although objects are usually considered “better” when they are bigger in size, objects described with linguistic diminution can also refer to those that are emotionally positive. Across three experiments conducted in Polish, we examined this lexical ambiguity in terms of mood (Experiment 1), subjective quality and monetary value (Experiment 2), and choice selection (Experiment 3). Overall, we found that people evaluate objects differently depending on the linguistic form (i.e., with or without diminution) with which they are described, and that it was related to the perceptual representation of these objects, and not their affective status. Objects described with diminution are evaluated as less satisfying and of lesser value and this effect is attributed to the way participants represent the objects (i.e., encoded and memorized). The generalizability of these effects is discussed. PMID:27721802
Professional Training of Specialists in International Marketing in Poland
ERIC Educational Resources Information Center
Zukowski, Wojciech
2015-01-01
Polish experience in training specialists in international marketing in the context of globalization and integration processes has been studied. A range of theoretical resources, namely Market Entry Strategy for Poland; the articles dedicated to international marketing and economy development (W. Grzegorczyk, M. Viachevskyi, M. Urbanetst); program…
Gościński, Igor; Wiernikowski, Adam; Zawiliński, Jarosław
2014-01-01
The Cracow Physicians Society (CPS) since inception in 1866, maintain close liaison with the Faculty of Medicine of the Jagiellonian University by the person of president, board members and ordinary members of the Society who are also employees of the University. They share a number of common initiatives. Many distinguished professors are honorary members of the Society. CPS annually rewards outstanding doctoral and postdoctoral works award named professor Sych, and also awards diplomas and medals to deserving individuals for professional, scientific and organizational work. CPS cooperates with the Association of Graduates of the Medical Faculties of the Jagiellonian University, Polish Academy of Learning and the Division of Krakow Polish Academy of Sciences and numerous specialized medical societies in the medical integration and to focus physicians around deontological and ethical problems, basic sciences, medical diagnostics, therapeutics, medical history and culture.
NASA Astrophysics Data System (ADS)
Lambropoulos, John C.; Fang, Tong; Xu, Su; Gracewski, Sheryl M.
1995-09-01
We discuss a constitutive model describing the permanent densification of fused silica under large applied pressures and shear stresses. The constitutive law is assumed to be rate- independent, and uses a yield function coupling hydrostatic pressure and shear stress, a flow rule describing the evolution of permanent strains after initial densification, and a hardening rule describing the dependence of the incremental densification on the levels of applied stresses. The constitutive law accounts for multiaxial states of stress, since during polishing and grinding operations complex stress states occur in a thin surface layer due to the action of abrasive particles. Due to frictional and other abrasive forces, large shear stresses are present near the surface during manufacturing. We apply the constitutive law in estimating the extent of the densified layer during the mechanical interaction of an abrasive grain and a flat surface.
NASA Technical Reports Server (NTRS)
Moskowitz, Milton E.; Bly, Jennifer M.; Matthiesen, David H.
1997-01-01
Experiments were conducted in the crystal growth furnace (CGF) during the first United States Microgravity Laboratory (USML-1), the STS-50 flight of the Space Shuttle Columbia, to determine the segregation behavior of selenium in bulk GaAs in a microgravity environment. After the flight, the selenium-doped GaAs crystals were sectioned, polished, and analyzed to determine the free carrier concentration as a function of position, One of the two crystals initially exhibited an axial concentration profile indicative of diffusion controlled growth, but this profile then changed to that predicted for a complete mixing type growth. An analytical model, proposed by Naumann [R.J. Naumann, J. Crystal Growth 142 (1994) 253], was utilized to predict the maximum allowable microgravity disturbances transverse to the growth direction during the two different translation rates used for each of the experiments. The predicted allowable acceleration levels were 4.86 microgram for the 2.5 micrometers/s furnace translation rate and 38.9 microgram for the 5.0 micrometers/s rate. These predicted values were compared to the Orbital Acceleration Research Experiment (OARE) accelerometer data recorded during the crystal growth periods for these experiments. Based on the analysis of the OARE acceleration data and utilizing the predictions from the analytical model, it is concluded that the change in segregation behavior was not caused by any acceleration events in the microgravity environment.
Removing Silicon Monoxide From Nickel Mirrors
NASA Technical Reports Server (NTRS)
Zaniewski, John J.
1987-01-01
Combination of polishing tool and polishing mixture used to remove adherent fragments of silicon monoxide protective coatings from nickel/aluminum mirrors without altering shapes or harming polishes of mirror surfaces. Polishing technique developed to prepare stained mirrors for recoating to restore high reflectance.
ERIC Educational Resources Information Center
Miekisz, Aneta; Haman, Ewa; Luniewska, Magdalena; Kus, Katarzyna; O'Toole, Ciara; Katsos, Napoleon
2017-01-01
The expressive lexical skills of 53 Polish bilinguals aged 24-36 months living in the UK and Ireland were assessed using Polish and British English adaptations of the MacArthur-Bates Communicative Development Inventories. Polish vocabulary scores were compared to those of 53 Polish monolinguals matched for age, gender and parental education. The…
Cancer morbidity among polishers.
Järvholm, B; Thiringer, G; Axelson, O
1982-01-01
The mortality pattern among 86 men was determined to investigate the possible hazards of polishing steel. The men had polished steel with polishing paste for at least five years. The polishing pastes had contained tallow, beeswax, carnauba wax, alundum, carborundum, ferric oxide, and chalk. A total of 18 men had died compared with 13.3 expected. Four had died of stomach cancer compared with 0.44 expected (p less than 0.005). The mortality for other causes of death was not increased. The study does not permit any definite conclusion but indicates a possible cancer hazard among polishers. PMID:7066237
Zerodur polishing process for high surface quality and high efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tesar, A.; Fuchs, B.
1992-08-01
Zerodur is a glass-ceramic composite importance in applications where temperature instabilities influence optical and mechanical performance, such as in earthbound and spaceborne telescope mirror substrates. Polished Zerodur surfaces of high quality have been required for laser gyro mirrors. Polished surface quality of substrates affects performance of high reflection coatings. Thus, the interest in improving Zerodur polished surface quality has become more general. Beyond eliminating subsurface damage, high quality surfaces are produced by reducing the amount of hydrated material redeposited on the surface during polishing. With the proper control of polishing parameters, such surfaces exhibit roughnesses of
Bacterial carriage on the fingernails of OR nurses.
Wynd, C A; Samstag, D E; Lapp, A M
1994-11-01
This study provides statistically significant data that demonstrate that chipped fingernail polish or fingernail polish worn longer than four days fosters increased numbers of bacteria on the fingernails of OR nurses after surgical hand scrubs. There were no significant correlations between fingernail length and the numbers of bacterial colonies on the fingernails of the study groups tested after performing a standard surgical hand scrub. A convenience sample of 102 perioperative nurses with either freshly polished fingernails; chipped fingernail polish; or natural, polish-free fingernails participated. The data suggest OR nurses can wear fresh fingernail polish on healthy fingernails without risking increased bacterial counts.
Huettig, Fabian; Kustermann, Achim; Kuscu, Ebru; Geis-Gerstorfer, Jürgen; Spintzyk, Sebastian
2017-11-01
Occlusal splints to treat bruxism are commonly made from polymethylmethacrylate (PMMA) in a manual workflow (powder-liquid technique). Today digitalization allows a machine-based manufacturing in subtractive (milling) and additive (printing) means using industrial-made PMMA or comparable resins. An in-vitro study should assess the surface finish and screen the wear resistance of conventional and industrial materials. Therefore, a total of 30 specimens made from conventionally PMMA (group C; powder-liquid, Palapress), polycarbonate ingots (group S; innoBlanc splint plus), and light-curing resin (group A; VarseoWax splint) were polished to examine the surface roughness (Ra) by profilometry and further analyzed by SEM. The specimens were loaded with a steatite ball moving 5000 times along 1cm with 5N of surface pressure under constant wetting (artificial saliva). The total height of profile (Pt) was calculated by further profilometry of the specimens. All specimen showed initially comparable Ra values ranging between 0.06 and 0.05µm (SD = 0.01) after polishing. SEM investigations revealed no visual cues for scratches or irregularities in any group. After abrasion test, the comparison of the wear depths, revealed mean Pt values of 111.4µm (SD = 18.5) in C, 85.7µm (SD = 21.5) in S, and 99.1µm (SD = 21.5) in A, whereas the mean of S was statistically different from C (p = 0.025). No signs of abrasion were found on the steatite balls. All materials showed comparable polished surfaces and a similar scale of wear. It remains questionable if the detected statistical differences are of clinical relevance, but indicates the need for tests of novel materials, especially in additive manufacturing. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Menapace, Joseph A.
2010-11-01
Over the last eight years we have been developing advanced MRF tools and techniques to manufacture meter-scale optics for use in Megajoule class laser systems. These systems call for optics having unique characteristics that can complicate their fabrication using conventional polishing methods. First, exposure to the high-power nanosecond and sub-nanosecond pulsed laser environment in the infrared (>27 J/cm2 at 1053 nm), visible (>18 J/cm2 at 527 nm), and ultraviolet (>10 J/cm2 at 351 nm) demands ultra-precise control of optical figure and finish to avoid intensity modulation and scatter that can result in damage to the optics chain or system hardware. Second, the optics must be super-polished and virtually free of surface and subsurface flaws that can limit optic lifetime through laser-induced damage initiation and growth at the flaw sites, particularly at 351 nm. Lastly, ultra-precise optics for beam conditioning are required to control laser beam quality. These optics contain customized surface topographical structures that cannot be made using traditional fabrication processes. In this review, we will present the development and implementation of large-aperture MRF tools and techniques specifically designed to meet the demanding optical performance challenges required in large aperture high-power laser systems. In particular, we will discuss the advances made by using MRF technology to expose and remove surface and subsurface flaws in optics during final polishing to yield optics with improve laser damage resistance, the novel application of MRF deterministic polishing to imprint complex topographical information and wavefront correction patterns onto optical surfaces, and our efforts to advance the technology to manufacture largeaperture damage resistant optics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menapace, J A
2010-10-27
Over the last eight years we have been developing advanced MRF tools and techniques to manufacture meter-scale optics for use in Megajoule class laser systems. These systems call for optics having unique characteristics that can complicate their fabrication using conventional polishing methods. First, exposure to the high-power nanosecond and sub-nanosecond pulsed laser environment in the infrared (>27 J/cm{sup 2} at 1053 nm), visible (>18 J/cm{sup 2} at 527 nm), and ultraviolet (>10 J/cm{sup 2} at 351 nm) demands ultra-precise control of optical figure and finish to avoid intensity modulation and scatter that can result in damage to the optics chainmore » or system hardware. Second, the optics must be super-polished and virtually free of surface and subsurface flaws that can limit optic lifetime through laser-induced damage initiation and growth at the flaw sites, particularly at 351 nm. Lastly, ultra-precise optics for beam conditioning are required to control laser beam quality. These optics contain customized surface topographical structures that cannot be made using traditional fabrication processes. In this review, we will present the development and implementation of large-aperture MRF tools and techniques specifically designed to meet the demanding optical performance challenges required in large-aperture high-power laser systems. In particular, we will discuss the advances made by using MRF technology to expose and remove surface and subsurface flaws in optics during final polishing to yield optics with improve laser damage resistance, the novel application of MRF deterministic polishing to imprint complex topographical information and wavefront correction patterns onto optical surfaces, and our efforts to advance the technology to manufacture large-aperture damage resistant optics.« less
Multiwavelength digital holography for polishing tool shape measurement
NASA Astrophysics Data System (ADS)
Lédl, Vít.; Psota, Pavel; Václavík, Jan; Doleček, Roman; Vojtíšek, Petr
2013-09-01
Classical mechano-chemical polishing is still a valuable technique, which gives unbeatable results for some types of optical surfaces. For example, optics for high power lasers requires minimized subsurface damage, very high cosmetic quality, and low mid spatial frequency error. One can hardly achieve this with use of subaperture polishing. The shape of the polishing tool plays a crucial role in achieving the required form of the optical surface. Often the shape of the polishing tool or pad is not known precisely enough during the manufacturing process. The tool shape is usually premachined and later is changed during the polishing procedure. An experienced worker could estimate the shape of the tool indirectly from the shape of the polished element, and that is why he can achieve the required shape in few reasonably long iterative steps. Therefore the lack of the exact tool shape knowledge is tolerated. Sometimes, this indirect method is not feasible even if small parts are considered. Moreover, if processes on machines like planetary (continuous) polishers are considered, the incorrect shape of the polishing pad could extend the polishing times extremely. Every iteration step takes hours. Even worse, polished piece could be wasted if the pad has a poor shape. The ability of the tool shape determination would be very valuable in those types of lengthy processes. It was our primary motivation to develop a contactless measurement method for large diffusive surfaces and demonstrate its usability. The proposed method is based on application of multiwavelength digital holographic interferometry with phase shift.
Polishing parameter optimization for end-surface of chalcogenide glass fiber connector
NASA Astrophysics Data System (ADS)
Guo, Fangxia; Dai, Shixun; Tang, Junzhou; Wang, Xunsi; Li, Xing; Xu, Yinsheng; Wu, Yuehao; Liu, Zijun
2017-11-01
We have investigated the optimization parameters for polishing end-surface of chalcogenide glass fiber connector in the paper. Six SiC abrasive particles of different sizes were used to polish the fiber in order of size from large to small. We analyzed the effects of polishing parameters such as particle sizes, grinding speeds and polishing durations on the quality of the fiber end surface and determined the optimized polishing parameters. We found that, high-quality fiber end surface can be achieved using only three different SiC abrasives. The surface roughness of the final ChG fiber end surface is about 48 nm without any scratches, spots and cracks. Such polishing processes could reduce the average insertion loss of the connector to about 3.4 dB.
Surface Roughness and Gloss of Actual Composites as Polished With Different Polishing Systems.
Rodrigues-Junior, S A; Chemin, P; Piaia, P P; Ferracane, J L
2015-01-01
This in vitro study evaluated the effect of polishing with different polishing systems on the surface roughness and gloss of commercial composites. One hundred disk-shaped specimens (10 mm in diameter × 2 mm thick) were made with Filtek P-90, Filtek Z350 XT, Opallis, and Grandio. The specimens were manually finished with #400 sandpaper and polished by a single operator using three multistep systems (Superfix, Diamond Pro, and Sof-lex), one two-step system (Polidores DFL), and one one-step system (Enhance), following the manufacturer's instructions. The average surface roughness (μm) was measured with a surface profilometer (TR 200 Surface Roughness Tester), and gloss was measured using a small-area glossmeter (Novo-Curve, Rhopoint Instrumentation, East Sussex, UK). Data were analyzed by two-way analysis of variance and Tukey's test (α=0.05). Statistically significant differences in surface roughness were identified by varying the polishing systems (p<0.0001) and by the interaction between polishing system and composite (p<0.0001). Pairwise comparisons revealed higher surface roughness for Grandio when polished with Sof-Lex and Filtek Z250 and Opallis when polished with Enhance. Gloss was influenced by the composites (p<0.0001), the polishing systems (p<0.0001), and the interaction between them (p<0.0001). The one-step system, Enhance, produced the lowest gloss for all composites. Surface roughness and gloss were affected by composites and polishing systems. The interaction between both also influenced these surface characteristics, meaning that a single polishing system will not behave similarly for all composites. The multistep systems produced higher gloss, while the one-step system produced the highest surface roughness and the lowest gloss of all.
Steiner, René; Beier, Ulrike S; Heiss-Kisielewsky, Irene; Engelmeier, Robert; Dumfahrt, Herbert; Dhima, Matilda
2015-06-01
During the insertion appointment, the practitioner is often faced with the need to adjust ceramic surfaces to fit a restoration to the adjacent or opposing dentition and soft tissues. The purpose of this study was to assess the ceramic surface smoothness achieved with various commercially available ceramic polishing kits on different commonly used ceramic systems. The reliability of the cost of a polishing kit as an indicator of improved surface smoothness was assessed. A total of 350 ceramic surfaces representing 5 commonly available ceramic systems (IPS Empress Esthetic, IPS e.max Press, Cergo Kiss, Vita PM 9, Imagine PressX) were treated with 5 types of ceramic polishing systems (Cerapreshine, 94006C, Ceramiste, Optrafine, Zenostar) by following the manufacturers' guidelines. The surface roughness was measured with a profilometer (Taylor Hobson; Precision Taylor Hobson Ltd). The effects of ceramic systems and polishing kits of interest on surface roughness were analyzed by 2-way ANOVA, paired t test, and Bonferroni corrected significance level. The ceramic systems and polishing kits statistically affected surface roughness (P<.001).The polishing kit Zenostar on IPS e.max Press created the smoothest ceramic surface. No correlation could be established between the high cost of the polishing kit and low surface roughness. None of the commonly used ceramic polishing kits could create a surface smoother than that of glazed ceramic (P<.001). The inclusion of a diamond polishing paste step is recommended to improve surface smoothness (P<.001). The cost of ceramic polishing kits is not recommended as a reliable indicator of better performance of ceramic polishing kits (P>.30). Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Examination of the polished surface character of fused silica.
Tesar, A A; Fuchs, B A; Hed, P P
1992-12-01
Investigation of the surface character of fused silica polished with various compounds dispersed in water identified pH 4 as the optimum condition for high quality. Analyses support the conclusion that at this pH redeposition of hydrated material onto the surface during polishing is limited. Comparative polishing results for Zerodur are included. Improvement of the laser-damage threshold of a coating on the pH 4 polished fused silica is suggested.
Examination of the polished surface character of fused silica
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tesar, A.A.; Fuchs, B.A.; Hed, P.P.
1992-12-01
Investigation of the surface character of fused silica polished with various compounds dispersed in water identified pH 4 as the optimum condition for high quality. Analyses support the conclusion that at this pH redeposition of hydrated material onto the surface during polishing is limited. Comparative polishing results for Zerodur are included. Improvement of the laser-damage threshold of a coating on the pH 4 polished fused silica is suggested.
Language Switching in the Production of Phrases
ERIC Educational Resources Information Center
Tarlowski, Andrzej; Wodniecka, Zofia; Marzecova, Anna
2013-01-01
The language switching task has provided a useful insight into how bilinguals produce language. So far, however, the studies using this method have been limited to lexical access. The present study provides empirical evidence on language switching in the production of simple grammar structures. In the reported experiment, Polish-English unbalanced…
The effects of different polishing techniques on the staining resistance of CAD/CAM resin-ceramics
Demirci, Tevfik; Demirci, Gamze; Sagsoz, Nurdan Polat; Yildiz, Mehmet
2016-01-01
PURPOSE The purposes of this study were to evaluate the staining resistance of CAD/CAM resin-ceramics polished with different techniques and to determine the effectiveness of the polishing techniques on resin-ceramics, comparing it with that of a glazed glass-ceramic. MATERIALS AND METHODS Four different CAD/CAM ceramics (feldspathic ceramic: C-CEREC Blocs, (SIRONA) and three resin-ceramics: L-Lava Ultimate, (3M ESPE), E-Enamic, (VITA) and CS-CeraSmart, (GC)) and one light cure composite resin: ME-Clearfil Majesty Esthetic (Kuraray) were used. Only C samples were glazed (gl). Other restorations were divided into four groups according to the polishing technique: nonpolished control group (c), a group polished with light cure liquid polish (Biscover LV BISCO) (bb), a group polished with ceramic polishing kit (Diapol, EVE) (cd), and a group polished with composite polishing kit (Clearfil Twist Dia, Kuraray) (kc). Glazed C samples and the polished samples were further divided into four subgroups and immersed into different solutions: distilled water, tea, coffee, and fermented black carrot juice. Eight samples (8 × 8 × 1 mm) were prepared for each subgroup. According to CIELab system, four color measurements were made: before immersion, immersion after 1 day, after 1 week, and after 1 month. Data were analyzed with repeated measures of ANOVA (α=.05). RESULTS The highest staining resistance was found in gl samples. There was no difference among gl, kc and cd (P>.05). Staining resistance of gl was significantly higher than that of bb (P<.05). Staining resistances of E and CS were significantly higher than those of L and ME (P<.05). CONCLUSION Ceramic and composite polishing kits can be used for resin ceramics as a counterpart of glazing procedure used for full ceramic materials. Liquid polish has limited indications for resin ceramics. PMID:28018558
Influence of polishing on surface roughness following toothbrushing wear of composite resins.
Dalla-Vecchia, Karine Battestin; Taborda, Talita Damas; Stona, Deborah; Pressi, Heloísa; Burnett Júnior, Luiz Henrique; Rodrigues-Junior, Sinval Adalberto
2017-01-01
This study aimed to evaluate the influence of different polishing systems on the surface roughness of composite resins following procedures to simulate the effects of toothbrushing over time. Four currently available commercial composites were used to make 128 cylindrical specimens. The specimens were randomly allocated to polishing with a 1-step polisher or 1 of 3 multistep polishers (n = 8 per group). The baseline surface roughness was measured, and the specimens were submitted to 5000, 10,000, and 20,000 brushing cycles to represent toothbrushing throughout 6, 12, and 24 months, respectively. Results showed that surface roughness was influenced by the type of composite and polishing system and was not influenced by the simulated toothbrushing time. However, the surface roughness, as challenged by toothbrushing wear, was affected by the interaction among the composite, the polisher, and the toothbrushing time. The 1-step polisher produced the highest surface roughness and influenced toothbrushing wear resistance of some composites.
Pseudo-random tool paths for CNC sub-aperture polishing and other applications.
Dunn, Christina R; Walker, David D
2008-11-10
In this paper we first contrast classical and CNC polishing techniques in regard to the repetitiveness of the machine motions. We then present a pseudo-random tool path for use with CNC sub-aperture polishing techniques and report polishing results from equivalent random and raster tool-paths. The random tool-path used - the unicursal random tool-path - employs a random seed to generate a pattern which never crosses itself. Because of this property, this tool-path is directly compatible with dwell time maps for corrective polishing. The tool-path can be used to polish any continuous area of any boundary shape, including surfaces with interior perforations.
Saiki, Osamu; Koizumi, Hiroyasu; Akazawa, Nobutaka; Kodaira, Akihisa; Okamura, Kentaro; Matsumura, Hideo
2016-01-01
This study compared the wear characteristics of a heat-pressed lithium disilicate ceramic material opposed to feldspathic porcelain, a lithium disilicate glass ceramic, and zirconia materials. Ceramic plate specimens were prepared from feldspathic porcelain (EX-3 nA1B), lithium disilicate glass ceramics (e.max CAD MO1/C14), and zirconia (Katana KT 10) and then ground or polished. Rounded rod specimens were fabricated from heat-pressed lithium disilicate glass ceramic (e.max press LT A3) and then glazed or polished. A sliding wear testing apparatus was used for wear testing. Wear of glazed rods was greater than that of polished rods when they were abraded with ground zirconia, ground porcelain, polished porcelain, or polished lithium disilicate ceramics. For both glazed and polished rods, wear was greater when the rods were abraded with ground plates. The findings indicate that application of a polished surface rather than a glazed surface is recommended for single restorations made of heat-pressed lithium disilicate material. In addition, care must be taken when polishing opposing materials, especially those used in occlusal contact areas. (J Oral Sci 58, 117-123, 2016).
Polish Higher Education: Intersectoral Distinctiveness
ERIC Educational Resources Information Center
Musial, Joanna
2014-01-01
This study analyzes degrees of differences between the private and public sectors of Polish higher education. It finds them to be strong: Polish private institutions function very differently from Polish public institutions and these differences correspond with those found in the literature on higher education elsewhere in the world. Polish…
ERIC Educational Resources Information Center
Bidwell, Charles E.
This volume, one of a series of concise but relatively exhaustive descriptions of the grammatical structures of the principal standard Slavic languages, contains an outline of Polish morphology. The four major sections are morphophonemics, nominal inflection, the Polish verb (Part 1--stem alternation and conjugation, and the Polish verb (Part…
Water Bubble revealing a refracted image of ESA Andre Kuipers
2012-02-28
ISS030-E-108804 (28 Feb. 2012) -- A close look at this four-inch polished metal sphere onboard the International Space Station reveals a reflected image of NASA astronaut Don Pettit, Expedition 30 flight engineer. Using a 105-mm lens, Pettit took a series of pictures of the sphere. Also visible is hardware from the Capillary Flow Experiment-2 (CFE-2) Vane Gap 1 Experiment, in the U.S. Laboratory Destiny.
The advancement of the high precision stress polishing
NASA Astrophysics Data System (ADS)
Li, Chaoqiang; Lei, Baiping; Han, Yu
2016-10-01
The stress polishing is a kind of large-diameter aspheric machining technology with high efficiency. This paper focuses on the principle, application in the processing of large aspheric mirror, and the domestic and foreign research status of stress polishing, aimed at the problem of insufficient precision of mirror surface deformation calculated by some traditional theories and the problem that the output precision and stability of the support device in stress polishing cannot meet the requirements. The improvement methods from these three aspects are put forward, the characterization method of mirror's elastic deformation in stress polishing, the deformation theory of influence function and the calculation of correction force, the design of actuator's mechanical structure. These improve the precision of stress polishing and provide theoretical basis for the further application of stress polishing in large-diameter aspheric machining.
Desalu, I; Diakparomre, O I; Salami, A O; Abiola, A O
2013-12-01
AIMS AND OBJECTIVES - Pulse oximetry is mandatory during anaesthesia, sedation and transfer of critically ill patients. The effect of nail polish and acrylic nails on the accuracy of saturation reading is inconsistent. The Lifebox pulse oximeter is reliable and recommended for low and middle income countries. We investigated its accuracy in the presence of 4 nail colours and acrylic nails SUBJECTS AND METHODS Fifty non-smoking volunteers had their fingers numbered from right to left (little finger of right hand =1 and little finger of left hand =10). Alternate fingers were nails painted with clear, red, brown and black nail polish and the 5th finger had acrylic nail applied. The corresponding finger on the other hand acted as control. The oxygen saturation was determined using the Lifebox pulse oximeter. Results All fingers (100%) with clear nail polish, red nail polish and acrylic nails recorded a saturation value. Each of the mean saturation value for clear nail polish, red nail polish and acrylic nails was not significantly different from the control mean (p= 0.378, 0.427 and 0.921). Only 12% and 64% of nails polished black and brown respectively recorded a saturation value. The mean SpO- for black and brown polish were significantly different from their control mean (p<0.001). CONCLUSION Black and brown polish resulted in a significant decrease in SpO with the Lifebox oximeter. Dark coloured nail polish should be removed prior to SpO2 determination to ensure that accurate readings can be obtained.
Terminology extraction from medical texts in Polish
2014-01-01
Background Hospital documents contain free text describing the most important facts relating to patients and their illnesses. These documents are written in specific language containing medical terminology related to hospital treatment. Their automatic processing can help in verifying the consistency of hospital documentation and obtaining statistical data. To perform this task we need information on the phrases we are looking for. At the moment, clinical Polish resources are sparse. The existing terminologies, such as Polish Medical Subject Headings (MeSH), do not provide sufficient coverage for clinical tasks. It would be helpful therefore if it were possible to automatically prepare, on the basis of a data sample, an initial set of terms which, after manual verification, could be used for the purpose of information extraction. Results Using a combination of linguistic and statistical methods for processing over 1200 children hospital discharge records, we obtained a list of single and multiword terms used in hospital discharge documents written in Polish. The phrases are ordered according to their presumed importance in domain texts measured by the frequency of use of a phrase and the variety of its contexts. The evaluation showed that the automatically identified phrases cover about 84% of terms in domain texts. At the top of the ranked list, only 4% out of 400 terms were incorrect while out of the final 200, 20% of expressions were either not domain related or syntactically incorrect. We also observed that 70% of the obtained terms are not included in the Polish MeSH. Conclusions Automatic terminology extraction can give results which are of a quality high enough to be taken as a starting point for building domain related terminological dictionaries or ontologies. This approach can be useful for preparing terminological resources for very specific subdomains for which no relevant terminologies already exist. The evaluation performed showed that none of the tested ranking procedures were able to filter out all improperly constructed noun phrases from the top of the list. Careful choice of noun phrases is crucial to the usefulness of the created terminological resource in applications such as lexicon construction or acquisition of semantic relations from texts. PMID:24976943
Terminology extraction from medical texts in Polish.
Marciniak, Małgorzata; Mykowiecka, Agnieszka
2014-01-01
Hospital documents contain free text describing the most important facts relating to patients and their illnesses. These documents are written in specific language containing medical terminology related to hospital treatment. Their automatic processing can help in verifying the consistency of hospital documentation and obtaining statistical data. To perform this task we need information on the phrases we are looking for. At the moment, clinical Polish resources are sparse. The existing terminologies, such as Polish Medical Subject Headings (MeSH), do not provide sufficient coverage for clinical tasks. It would be helpful therefore if it were possible to automatically prepare, on the basis of a data sample, an initial set of terms which, after manual verification, could be used for the purpose of information extraction. Using a combination of linguistic and statistical methods for processing over 1200 children hospital discharge records, we obtained a list of single and multiword terms used in hospital discharge documents written in Polish. The phrases are ordered according to their presumed importance in domain texts measured by the frequency of use of a phrase and the variety of its contexts. The evaluation showed that the automatically identified phrases cover about 84% of terms in domain texts. At the top of the ranked list, only 4% out of 400 terms were incorrect while out of the final 200, 20% of expressions were either not domain related or syntactically incorrect. We also observed that 70% of the obtained terms are not included in the Polish MeSH. Automatic terminology extraction can give results which are of a quality high enough to be taken as a starting point for building domain related terminological dictionaries or ontologies. This approach can be useful for preparing terminological resources for very specific subdomains for which no relevant terminologies already exist. The evaluation performed showed that none of the tested ranking procedures were able to filter out all improperly constructed noun phrases from the top of the list. Careful choice of noun phrases is crucial to the usefulness of the created terminological resource in applications such as lexicon construction or acquisition of semantic relations from texts.
Kokowski, Michał
2015-01-01
The article sketches the history of naukoznawstwo (literally meaning the science connoisseurship or the science of science or science studies) in Poland from the 1910s to the end of the Cold War (1991), and the recovery of full political independence in 1993. It outlines the changing research perspectives of this interdisciplinary field of knowledge in Poland against a background of changing political conditions caused by the reconfigurations of the political order. The first part of the article concerns the period from the 1910s, when Poland was occupied by Russia, Prussia, and Austria, through the regaining of independence by Poland in 1918, the reconstruction of the state in 1918-1939; the second part--World War II; the third part--the period from the initial period of Soviet dominance (1944-1954) in Poland and simultaneously the beginnings of the Cold War (1947-1954), the period 1955-1956 (when the Polish state was liberated from Sovietization), through the different political crises in October 1956, March 1968, December 1970, and June 1976, to the emergence of the Independent Self-governing Trade Union Solidarity in September 1980, the end of the Cold War (1991), and the recovery of full political independence in 1993. The article outlines the fundamental achievements of prominent Polish scholars (among others K. Twardowski, M. Ossowska, S. Ossowski, T. Kotarbiński, K. Ajdukiewicz, S. Michalski, F. Znaniecki, B. Suchodolski, L. Fleck, M. Choynowski, Z. Modzelewski, S. Amsterdamski), politicians (among others B. Bierut, E. Krasowska), politicians and scholars (H. Jabłoński, S. Kulczyński), as well as committees (among others the Academic Section of the Józef Mianowski Fund, The Science of Science Committee of the Polish Academy of Sciences), schools of thought (among others the Lvov-Warsaw School of Philosophy), and academic units (among others the Science of Science Seminar in Kraków, the Department for the History of Science and Technology of the Polish Academy of Sciences, and The Department of Praxeology and Science of Science at the Institute for the Philosophy and Sociology of the Polish Academy of Sciences).
Dong, Zhichao; Cheng, Haobo; Tam, Hon-Yuen
2015-02-10
The velocity-varying regime used in deterministic subaperture polishing employs a time-invariant tool influence function (TIF) to figure localized surface errors by varying the transverse velocities of polishing tools. Desired transverse velocities have to be truncated if they exceed the maximal velocity of computer numerical control (CNC) machines, which induces excessive material removal and reduces figuring efficiency (FE). A time-variant (TV) TIF regime is presented, in which a TIF serves as a variable to compensate for excessive material removal when the transverse velocities are truncated. Compared with other methods, the TV-TIF regime exhibits better performance in terms of convergence rate, FE, and versatility; its operability can also be strengthened by a TIF library. Comparative experiments were conducted on a magnetorheological finishing machine to validate the effectiveness of the TV-TIF regime. Without a TV-TIF, the tool made an unwished dent (depth of 76 nm) at the center because of the velocity truncation problem. Through compensation with a TV-TIF, the dent was completely removed by the second figuring process, and a TV-TIF improved the FE from 0.029 to 0.066 mm(3)/h.
Riveros, Raul E; Yamaguchi, Hitomi; Mitsuishi, Ikuyuki; Takagi, Utako; Ezoe, Yuichiro; Kato, Fumiki; Sugiyama, Susumu; Yamasaki, Noriko; Mitsuda, Kazuhisa
2010-06-20
X-ray astronomy research is often limited by the size, weight, complexity, and cost of functioning x-ray optics. Micropore optics promises an economical alternative to traditional (e.g., glass or foil) x-ray optics; however, many manufacturing difficulties prevent micropore optics from being a viable solution. Ezoe et al. introduced microelectromechanical systems (MEMS) micropore optics having curvilinear micropores in 2008. Made by either deep reactive ion etching or x-ray lithography, electroforming, and molding (LIGA), MEMS micropore optics suffer from high micropore sidewall roughness (10-30nmrms) which, by current standards, cannot be improved. In this research, a new alternating magnetic-field-assisted finishing process was developed using a mixture of ferrofluid and microscale abrasive slurry. A machine was built, and a set of working process parameters including alternating frequency, abrasive size, and polishing time was selected. A polishing experiment on a LIGA-fabricated MEMS micropore optic was performed, and a change in micropore sidewall roughness of 9.3+/-2.5nmrms to 5.7+/-0.7nmrms was measured. An improvement in x-ray reflectance was also seen. This research shows the feasibility and confirms the effects of this new polishing process on MEMS micropore optics.
NASA Astrophysics Data System (ADS)
Hooper, Abigail R.; Boffa, Christopher C.; Sarkas, Harry W.; Cureton, Kevin
2015-08-01
When building an optical system, optical fabricators and designers meticulously choose the glass types for their application knowing that each one will have different chemical, thermal and mechanical properties. As the requirements for new optical systems have grown more demanding, the range of available glass types has vastly expanded and the specifications on the produced products have grown tighter. In an attempt to simplify processes and streamline consumable purchases, optical polishing houses often rely on one polishing slurry to manage these vast array of glass types. An unforeseen consequence of these practices can be a reduction in productivity by reduced removal rate, poor yields and frequent rework all translating into higher costs and reduced profitability. In this paper, the authors will examine the impact slurry pH has on glass types of different compositions and chemical, thermal and mechanical properties when using a double-sided polishing process. Experiments will use material removal rate, surface quality, and surface figure to provide insight into improving process control for differing glass types. Further guidance will be provided on how simple on-site monitoring and adjustment can deliver improved profitability on challenging substrates.
Zhang, Yifan; Dai, Yifan; Tie, Guipeng; Hu, Hao
2016-10-10
As a kind of important nonlinear optical element, KDP crystal has great demand in the inertial confinement fusion system. Based on the dissolution mechanism of solid materials, the factors that affect the material removal rate of KDP crystal in magnetorheological (MR) water-dissolution polishing are investigated to improve the machining efficiency. It is found that the material removal rate is proportional to the product of the saturation concentration and diffusion coefficient, and the relationship between the removal efficiency and the temperature meets the unilateral Gaussian function. Polishing experiments are carried out on a magnetorheological finishing (MRF) machine with self-designed MRF fluid heating devices. The experimental results show that practical efficiency-temperature curve is consistent with the theoretical curve, and the maximum machining efficiency increases by about 50% with the rise of temperature from 294 to 302 K. Meanwhile, when the MR fluid temperature is lower than 308 K, the crystal surface quality and surface roughness in different processing temperatures have no remarkable difference with constant crystal temperature (294 K). This research indicates that it is feasible to drastically improve KDP crystal MRF efficiency by controlling the processing temperature.
Figure correction of a metallic ellipsoidal neutron focusing mirror
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Jiang, E-mail: jiang.guo@riken.jp; Yamagata, Yutaka; Morita, Shin-ya
2015-06-15
An increasing number of neutron focusing mirrors is being adopted in neutron scattering experiments in order to provide high fluxes at sample positions, reduce measurement time, and/or increase statistical reliability. To realize a small focusing spot and high beam intensity, mirrors with both high form accuracy and low surface roughness are required. To achieve this, we propose a new figure correction technique to fabricate a two-dimensional neutron focusing mirror made with electroless nickel-phosphorus (NiP) by effectively combining ultraprecision shaper cutting and fine polishing. An arc envelope shaper cutting method is introduced to generate high form accuracy, while a fine polishingmore » method, in which the material is removed effectively without losing profile accuracy, is developed to reduce the surface roughness of the mirror. High form accuracy in the minor-axis and the major-axis is obtained through tool profile error compensation and corrective polishing, respectively, and low surface roughness is acquired under a low polishing load. As a result, an ellipsoidal neutron focusing mirror is successfully fabricated with high form accuracy of 0.5 μm peak-to-valley and low surface roughness of 0.2 nm root-mean-square.« less
NASA Astrophysics Data System (ADS)
Civitani, M. M.; Hołyszko, J.; Vecchi, G.; Basso, S.; Citterio, O.; Ghigo, M.; Pareschi, G.; Parodi, G.; Incorvaia, S.
2017-09-01
The implementation of an X-ray mission with high imaging capabilities, similar to those achieved with Chandra (< 1 arc second Half Energy Width, HEW), but with a much larger throughput (2.5 m2 effective area @1 keV), represents a compelling request by the scientific community. To this end the Lynx/XRS mission is being studied in USA, with the participation of international partners. In order to figure out the challenging technological task of the mirror fabrication, different approaches are considered, based on monolithic and segmented shells. Starting from the experience done on the glass prototypal shell realized in the past years, the direct polishing of thin (2 mm thick) fused silica monolithic shells is being investigated as a possible solution. A temporary stiffening structure is designed to support the shell during the figuring and polishing operations and to manage the handling up to its integration in the telescope structure. After the grinding and the polishing phases, in order to achieve the required surface accuracy, a final ion beam figuring correction is foreseen. In this paper, we present the technological process and the results achieved so far on a prototypal shell under development.
Ion beam figuring of silicon aspheres
NASA Astrophysics Data System (ADS)
Demmler, Marcel; Zeuner, Michael; Luca, Alfonz; Dunger, Thoralf; Rost, Dirk; Kiontke, Sven; Krüger, Marcus
2011-03-01
Silicon lenses are widely used for infrared applications. Especially for portable devices the size and weight of the optical system are very important factors. The use of aspherical silicon lenses instead of spherical silicon lenses results in a significant reduction of weight and size. The manufacture of silicon lenses is more challenging than the manufacture of standard glass lenses. Typically conventional methods like diamond turning, grinding and polishing are used. However, due to the high hardness of silicon, diamond turning is very difficult and requires a lot of experience. To achieve surfaces of a high quality a polishing step is mandatory within the manufacturing process. Nevertheless, the required surface form accuracy cannot be achieved through the use of conventional polishing methods because of the unpredictable behavior of the polishing tools, which leads to an unstable removal rate. To overcome these disadvantages a method called Ion Beam Figuring can be used to manufacture silicon lenses with high surface form accuracies. The general advantage of the Ion Beam Figuring technology is a contactless polishing process without any aging effects of the tool. Due to this an excellent stability of the removal rate without any mechanical surface damage is achieved. The related physical process - called sputtering - can be applied to any material and is therefore also applicable to materials of high hardness like Silicon (SiC, WC). The process is realized through the commercially available ion beam figuring system IonScan 3D. During the process, the substrate is moved in front of a focused broad ion beam. The local milling rate is controlled via a modulated velocity profile, which is calculated specifically for each surface topology in order to mill the material at the associated positions to the target geometry. The authors will present aspherical silicon lenses with very high surface form accuracies compared to conventionally manufactured lenses.
Study of Mechano-Chemical Machining of Ceramics and the Effect on Thin Film Behavior.
1981-06-01
polished 7 dry on nylon using NaCI 3 Photomicrographs of the etched surfaces of MgO polished 8 .wet on glass using NaCl 4 Surface profile and Nomarski ...micrograph of a Si wafer 10 taken before mechano-chemical polishing 5 Surface profile and Nomarski micrograph of a Si wafer 11 taken after mechano... Nomarski micrographs of mechano-chemically-polished 21 sapphire and tape-cast alumina 14 Surface profiles of mechano-chemically-polished sapphire 22
NASA Astrophysics Data System (ADS)
Chao, Zhang; Shijie, Su; Yilin, Yang; Guofu, Wang; Chao, Wang
2017-11-01
Aiming at the static balance of the controllable pitch propeller (CPP), a high efficiency static balance method based on the double-layer structure of the measuring table and gantry robot is adopted to realize the integration of torque measurement and corrected polish for controllable pitch propeller blade. The control system was developed by Microsoft Visual Studio 2015, and a composite platform prototype was developed. Through this prototype, conduct an experiment on the complete process of torque measurement and corrected polish based on a 300kg class controllable pitch propeller blade. The results show that the composite platform can correct the static balance of blade with a correct, efficient and labor-saving operation, and can replace the traditional method on static balance of the blade.
Development of a Computer-Controlled Polishing Process for X-Ray Optics
NASA Technical Reports Server (NTRS)
Khan, Gufran S.; Gubarev, Mikhail; Arnold, William; Ramsey, Brian
2009-01-01
The future X-ray observatory missions require grazing-incidence x-ray optics with angular resolution of < 5 arcsec half-power diameter. The achievable resolution depends ultimately on the quality of polished mandrels from which the shells are replicated. With an aim to fabricate better shells, and reduce the cost/time of mandrel production, a computer-controlled polishing machine is developed for deterministic and localized polishing of mandrels. Cylindrical polishing software is also developed that predicts the surface residual errors under a given set of operating parameters and lap configuration. Design considerations of the polishing lap are discussed and the effects of nonconformance of the lap and the mandrel are presented.
Polish system of education in maritime health care and medical assistance for seafarers.
Chodnik, Tomasz; Jeżewska, Maria; Jaremin, Bogdan; Kotłowski, Andrzej; Leszczyńska, Irena; Grubman-Nowak, Marta
2013-01-01
The Polish public awareness of the crucial importance of the own maritime economy to the very existenceof the national state has its historical reasons. The Polish maritime involvement has seen several dramaticcrises, but the Polish nationals have become an established group in the global marine trade workforceand are entitled to the proper health care. In this paper the main maritime health issues are mentioned.To meet the issues, also the national education system provides the opportunities for both seafarers andmedical professionals. The Polish doctors can specialise in the maritime medicine. In many cases the generalmedicine students formations include these topics as well. The psychological aspects are also takeninto account, both of the education of the seafarers and the organisational structure of the Polish healthcare system. Some recent aspects of the Polish participation in the international cooperation in the fieldof the medical support of the maritime economy are also described.
Electrochemical Polishing Applications and EIS of a Novel Choline Chloride-Based Ionic Liquid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wixtrom, Alex I.; Buhler, Jessica E.; Reece, Charles E.
2013-06-01
Minimal surface roughness is a critical feature for high-field superconducting radio frequency (SRF) cavities used to engineer particle accelerators. Current methods for polishing Niobium cavities typically utilize solutions containing a mixture of concentrated sulfuric and hydrofluoric acid. Polishing processes such as these are effective, yet there are many hazards and costs associated with the use (and safe disposal) of the concentrated acid solutions. An alternative method for electrochemical polishing of the cavities was explored using a novel ionic liquid solution containing choline chloride. Potentiostatic electrochemical impedance spectroscopy (EIS) was used to analyze the ionic polishing solution. Final surface roughness ofmore » the Nb was found to be comparable to that of the acid-polishing method, as assessed by atomic force microscopy (AFM). This indicates that ionic liquid-based electrochemical polishing of Nb is a viable replacement for acid-based methods for preparation of SRF cavities.« less
Internet Use of Polish by Polish Melburnians: Implications for Maintenance and Teaching
ERIC Educational Resources Information Center
Fitzgerald, Michael; Debski, Robert
2006-01-01
The Internet has become an important communication medium and it is having a significant impact on language use. The present study takes a "snapshot" of how the Polish language is currently used with modern communications technologies by Polish-Australians living in Melbourne. Through a questionnaire, it surveys which communications…
The Relationship between Polish and Other Slavic Languages.
ERIC Educational Resources Information Center
Birkenmayer, Sigmund S.
This paper discusses the relationship of Polish to the other languages considered to be within the Slavic group. The comparison is mainly phonological and considers the Proto-Slavic features still preserved in Polish as well as the distinctive features of Polish which have developed from Proto-Slavic. The development of vowels and consonants is…
Polish Migrant Parents of Secondary School Boys in the United Kingdom
ERIC Educational Resources Information Center
Tkacz, Daria; McGhee, Derek
2016-01-01
This article focuses on the parents of secondary school Polish boys and their capacity to realise their educational and professional aspirations for their children. Our primary finding is that although many Polish parents face considerable challenges in manoeuvring through the educational system, some Polish parents display a level of agency…
Subsurface Damage in Polishing Process of Silicon Carbide Ceramic
Gu, Yan; Zhu, Wenhui; Lin, Jieqiong; Lu, Mingming; Kang, Mingshuo
2018-01-01
Subsurface damage (SSD) in the polishing process of silicon carbide (SiC) ceramic presents one of the most significant challenges for practical applications. In this study, the theoretical models of SSD depth are established on the basis of the material removal mechanism and indentation fracture mechanics in the SiC ceramic polishing process. In addition, the three-dimensional (3D) models of single grit polishing are also developed by using the finite element simulation; thereby, the dynamic effects of different process parameters on SSD depth are analyzed. The results demonstrate that the material removal was mainly in brittle mode when the cutting depth was larger than the critical depth of the brittle material. The SSD depth increased as the polishing depth and abrasive grain size increased, and decreased with respect to the increase in polishing speed. The experimental results suggested a good agreement with the theoretical simulation results in terms of SSD depth as a function of polishing depth, spindle speed, and abrasive grain size. This study provides a mechanistic insight into the dependence of SSD on key operational parameters in the polishing process of SiC ceramic. PMID:29584694
Estimation of the dietary acrylamide exposure of the Polish population.
Mojska, Hanna; Gielecińska, Iwona; Szponar, Lucjan; Ołtarzewski, Maciej
2010-01-01
The objective of our study was to determine acrylamide content in the Polish foods and to assess the average dietary acrylamide exposure of the Polish population. We analysed the acrylamide content in Polish food using GCQ-MS/MS method. The daily dietary acrylamide exposure was computed using a probabilistic approach for the total Polish population (1-96 years) and for the following age groups: 1-6, 7-18 and 19-96, using Monte Carlo simulation technique. To assess the Polish population exposure to acrylamide present in food, food consumption data was taken from the 'Household Food Consumption and Anthropometric Survey in Poland'. The mean content of acrylamide in tested 225 samples of foodstuffs taken randomly all over Poland, ranged widely from 11 to 3647 microg/kg of product. For the total Polish population (1-96 years) the estimated acrylamide mean exposure is 0.43 microg/kg of body weight per day. The main sources of dietary acrylamide in Polish population were as follow: bread--supplied 45% of total dietary acrylamide intake, French fries and potato crisps--23%, roasted coffee--19%. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Design Considerations of Polishing Lap for Computer-Controlled Cylindrical Polishing Process
NASA Technical Reports Server (NTRS)
Khan, Gufran S.; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian
2010-01-01
The future X-ray observatory missions, such as International X-ray Observatory, require grazing incidence replicated optics of extremely large collecting area (3 m2) in combination with angular resolution of less than 5 arcsec half-power diameter. The resolution of a mirror shell depends ultimately on the quality of the cylindrical mandrels from which they are being replicated. Mid-spatial-frequency axial figure error is a dominant contributor in the error budget of the mandrel. This paper presents our efforts to develop a deterministic cylindrical polishing process in order to keep the mid-spatial-frequency axial figure errors to a minimum. Simulation studies have been performed to optimize the operational parameters as well as the polishing lap configuration. Furthermore, depending upon the surface error profile, a model for localized polishing based on dwell time approach is developed. Using the inputs from the mathematical model, a mandrel, having conical approximated Wolter-1 geometry, has been polished on a newly developed computer-controlled cylindrical polishing machine. We report our first experimental results and discuss plans for further improvements in the polishing process.
[Family structure of smoking onset and regular smoking among adolescents in Poland].
Kowalewska, Anna; Mazur, Joanna
2015-01-01
The aim of the research was to present the prevalence of the regular tobacco smoking, the age of Polish adolescents' smoking onset, as well as the trends in these behaviours in 2010-2014, and to identify the fam- ily factors related to early tobacco initiation, and regular smoking. The study was conducted in 2013/2014 as a part of the HBSC--Health Behaviour in School-aged Children: A WHO collaborative cross-national study, in a representative sample of Polish students (n=4545; 2263 boys, and 2282 girls), in three age groups, in mean age 11.6; 13.6; 15.6. The international, standard HBSC questionnaire was used. Results showed that prevalence of adolescents smoking onset, as well as regular smoking increased with age. There was no statistically significant difference comparing to HBSC study conducted in 2009/10. The important predictors of early tobacco initiation were: the male gender, living in broken or reconstructed family, and living in the rural area. Considering regular smoking, the most important risk factors were: older age (13,15 y.o.) and living with single parent or in reconstructed family. In planning the prevention strategies there is a need to take into account the family role in children and adolescents' smoking prevention, as well as how to support single parents.
Preliminary Test Results from 650 MHz Single Cell Medium Beta Cavities for Project X
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marhauser, Frank; Kneisel, Peter; Burrill, Andrew
We have fabricated two single cell 650 MHz {beta}=0.61 cavities of a JLab design, which possibly can be used for the proposed Project X proton linac application. Both cavities were manufactured at JLab from RRR>250 niobium sheet of 4 mm thickness using standard techniques such as deep drawing, electron beam welding, buffered chemical polishing, hydrogen degassing heat treatment, high pressure ultrapure water rinsing and clean room assembly. Initially cavity no. 1 was -- after final surface treatment by buffered chemical polishing (BCP) -- measured without any provisions for stiffening. As expected, the pressure sensitivity and the Lorentz Force detuning coefficientsmore » were relatively high; however, the RF performance was very encouraging: the cavity exhibited a Q-value > 10{sup 11} at 1.6K, corresponding to a residual resistance of < 1.5 n{Omega} The initial gradient was limited to E{sub acc} ~ 18 MV/m, limited by field emission. In a subsequent test, the cavity was re-rinsed and stiffened up, resulting in a somewhat improved mechanical behavior, but no improvement in rf performance. The second cavity was also tested twice, before and after low temperature baking. The results from all tests are reported in this contribution.« less
Jones, Gabrielle; Pihier, Nathalie; Vanbockstael, Caroline; Le Hello, Simon; Cadel Six, Sabrina; Fournet, Nelly; Jourdan-da Silva, Nathalie
2016-01-01
A prolonged outbreak of Salmonella enterica serotype Enteritidis occurred in northern France between December 2014 and April 2015. Epidemiological investigations following the initial notification on 30 December 2014 of five cases of salmonellosis (two confirmed S. Enteritidis) in young children residing in the Somme department revealed that all cases frequented the same food bank A. Further epidemiological, microbiological and food trace-back investigations indicated frozen beefburgers as the source of the outbreak and the suspected lot originating from Poland was recalled on 22 January 2015. On 2 March 2015 a second notification of S. Enteritidis cases in the Somme reinitiated investigations that confirmed a link with food bank A and with consumption of frozen beefburgers from the same Polish producer. In the face of a possible persistent source of contamination, all frozen beefburgers distributed by food bank A and from the same origin were blocked on 3 March 2015. Microbiological analyses confirmed contamination by S. Enteritidis of frozen beefburgers from a second lot remaining in cases’ homes. A second recall was initiated on 6 March 2015 and all frozen beefburgers from the Polish producer remain blocked after analyses identified additional contaminated lots over several months of production. PMID:27748250
Signs of Time - Metamorphoses of Historical Former Barrack Units
NASA Astrophysics Data System (ADS)
Gawryluk, Dorota
2017-10-01
The article analyzes the aesthetic changes which were introduced as regards the historic barracks in Polish cities from 1918 to the present day. The purpose of the analysis was to determine certain periods in history and to assign characteristic forms of initiatives in reference to the post-military objects to the aforementioned periods. The results of the research served as foundation for establishing three periods: 1) 1918-1939, 2) 1945-1989, 3) after 1989, which were determined in reference to typical types of approach towards the modernization of barrack buildings, conditioned by Poland’s political and economic situation. Consequently, the aesthetics of the modernization period characteristic for particular time frames were indicated-the “signs of time” readable in the architecture, referring to periods as follows: 1) symbols of Polishness, associated with regained independence - sculptures, statues, new buildings in contrast with the barracks remaining after the partition, 2) socialistic economy - using barrack as construction resource, utilitarian approach - adaptation to serve new civil functions, often for the needs of production technology, combination of historical and industrial forms, such initiatives on many occasions led to the moral degradation of former militarian districts 3) market economy - constructing new, positive identity and function of barracks buildings confirmed by the tactical changes in their architectural form.
Oxidation of 304 stainless steel in high-temperature steam
NASA Astrophysics Data System (ADS)
Ishida, Toshihisa; Harayama, Yasuo; Yaguchi, Sinnosuke
1986-08-01
An experiment on oxidation of 304 stainless steel was performed in steam between 900°C and 1350°C, using the spare cladding of the reactor of the nuclear-powered ship Mutsu. The temperature range was appropriate for a postulated loss of coolant accident (LOCA) analysis of a LWR. The oxidation kinetics were found to obey the parabolic law during the first period of 8 min. After the first period, the parabolic reaction rate constant decreased in the case of heating temperatures between 1100°C and 1250°C. At 1250°C, especially, a marked decrease was observed in the oxide scale-forming kinetics when the surface treated initially by mechanical polishing and given a residual stress. This enhanced oxidation resistance was attributed to the presence of a chromium-enriched layer which was detected by use of an X-ray microanalyzer. The oxidation kinetics equation obtained for the first 8 min is applicable to the model calculation of a hypothetical LOCA in a LWR, employing 304 stainless steel cladding.
NASA Astrophysics Data System (ADS)
Mahdieh, Mohammad Hossein; Mozaffari, Hossein
2017-10-01
In this paper, we investigate experimentally the effect of electric field on the size, optical properties and crystal structure of colloidal nanoparticles (NPs) of aluminum prepared by nanosecond Pulsed Laser Ablation (PLA) in deionized water. The experiments were conducted for two different conditions, with and without the electric field parallel to the laser beam path and the results were compared. To study the influence of electric field, two polished parallel aluminum metals plates perpendicular to laser beam path were used as the electrodes. The NPs were synthesized for target in negative, positive and neutral polarities. The colloidal nanoparticles were characterized using the scanning electron microscopy (SEM), UV-vis absorption spectroscopy and X-ray Diffraction (XRD). The results indicate that initial charge on the target has strong effect on the size properties and concentration of the synthesized nanoparticles. The XRD patterns show that the structure of produced NPs with and without presence of electric field is Boehmite (AlOOH).
Effects of Suction on Swept-Wing Transition
NASA Technical Reports Server (NTRS)
Saric, William S.
1998-01-01
Stability experiments are conducted in the Arizona State University Unsteady Wind Tunnel on a 45 deg swept airfoil. The pressure gradient is designed to provide purely crossflow-dominated transition; that is, the boundary layer is subcritical to Tollmien-Schlichting disturbances. The airfoil surface is hand polished to a 0.25 microns rms finish. Under these conditions, stationary crossflow disturbances grow to nonuniform amplitude due to submicron surface irregularities near the leading edge. Uniform stationary crossflow waves are produced by controlling the initial conditions with spanwise arrays of micron-sized roughness elements near the attachment line. Hot-wire measurements provide detailed maps of the crossflow wave structure, and accurate spectral decompositions isolate individual-mode growth rates for the fundamental and harmonic disturbances. Roughness spacing, roughness height, and Reynolds number are varied to investigate the growth of all amplified wavelengths. The measurements show early nonlinear mode interaction causing amplitude saturation well before transition. Comparisons with nonlinear parabolized stability equations calculations show excellent agreement in both the disturbance amplitude and the mode-shape profiles.
Introduction to the Navigation Team: Johnson Space Center EG6 Internship
NASA Technical Reports Server (NTRS)
Gualdoni, Matthew
2017-01-01
The EG6 navigation team at NASA Johnson Space Center, like any team of engineers, interacts with the engineering process from beginning to end; from exploring solutions to a problem, to prototyping and studying the implementations, all the way to polishing and verifying a final flight-ready design. This summer, I was privileged enough to gain exposure to each of these processes, while also getting to truly experience working within a team of engineers. My summer can be broken up into three projects: i) Initial study and prototyping: investigating a manual navigation method that can be utilized onboard Orion in the event of catastrophic failure of navigation systems; ii) Finalizing and verifying code: altering a software routine to improve its robustness and reliability, as well as designing unit tests to verify its performance; and iii) Development of testing equipment: assisting in developing and integrating of a high-fidelity testbed to verify the performance of software and hardware.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernandez-Garcia, C.; Bullard, D.; Hannon, F.
The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain <10 MV/m at the desired operating voltage aiming at little or no field emission once conditioned. Typical electrode surface preparation involves diamond-paste polishing by skilled personnel, requiring several weeks of effort per electrode. In this work, we describe a centrifugal barrel-polishing techniquemore » commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (~11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Here, tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.« less
Hernandez-Garcia, C.; Bullard, D.; Hannon, F.; ...
2017-09-11
The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain <10 MV/m at the desired operating voltage aiming at little or no field emission once conditioned. Typical electrode surface preparation involves diamond-paste polishing by skilled personnel, requiring several weeks of effort per electrode. In this work, we describe a centrifugal barrel-polishing techniquemore » commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (~11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Here, tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.« less
Effect finishing and polishing procedures on the surface roughness of IPS Empress 2 ceramic.
Boaventura, Juliana Maria Capelozza; Nishida, Rodrigo; Elossais, André Afif; Lima, Darlon Martins; Reis, José Mauricio Santos Nunes; Campos, Edson Alves; de Andrade, Marcelo Ferrarezi
2013-01-01
To evaluate the surface roughness of IPS Empress 2 ceramic when treated with different finishing/polishing protocols. Sixteen specimens of IPS Empress 2 ceramic were made from wax patterns obtained using a stainless steel split mold. The specimens were glazed (Stage 0-S0, control) and divided into two groups. The specimens in Group 1 (G1) were finished/polished with a KG Sorensen diamond point (S1), followed by KG Sorensen siliconized points (S2) and final polishing with diamond polish paste (S3). In Group 2 (G2), the specimens were finished/polished using a Shofu diamond point (S1), as well as Shofu siliconized points (S2) and final polishing was performed using Porcelize paste (S3). After glazing (S0) and following each polishing procedure (S1, S2 or S3), the surface roughness was measured using TALYSURF Series 2. The average surface roughness results were analyzed using ANOVA followed by Tukey post-hoc tests (α = 0.01) RESULTS: All of the polishing procedures yielded higher surface roughness values when compared to the control group (S0). S3 yielded lower surface roughness values when compared to S1 and S2. The proposed treatments negatively affected the surface roughness of the glazed IPS Empress 2 ceramic.
NASA Astrophysics Data System (ADS)
Hernandez-Garcia, C.; Bullard, D.; Hannon, F.; Wang, Y.; Poelker, M.
2017-09-01
The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain <10 MV/m at the desired operating voltage aiming at little or no field emission once conditioned. Typical electrode surface preparation involves diamond-paste polishing by skilled personnel, requiring several weeks of effort per electrode. In this work, we describe a centrifugal barrel-polishing technique commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (˜11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.
NASA Astrophysics Data System (ADS)
Cardenas, Nelson; Kyrish, Matthew; Taylor, Daniel; Fraelich, Margaret; Lechuga, Oscar; Claytor, Richard; Claytor, Nelson
2015-03-01
Electro-Chemical Polishing is routinely used in the anodizing industry to achieve specular surface finishes of various metals products prior to anodizing. Electro-Chemical polishing functions by leveling the microscopic peaks and valleys of the substrate, thereby increasing specularity and reducing light scattering. The rate of attack is dependent of the physical characteristics (height, depth, and width) of the microscopic structures that constitute the surface finish. To prepare the sample, mechanical polishing such as buffing or grinding is typically required before etching. This type of mechanical polishing produces random microscopic structures at varying depths and widths, thus the electropolishing parameters are determined in an ad hoc basis. Alternatively, single point diamond turning offers excellent repeatability and highly specific control of substrate polishing parameters. While polishing, the diamond tool leaves behind an associated tool mark, which is related to the diamond tool geometry and machining parameters. Machine parameters such as tool cutting depth, speed and step over can be changed in situ, thus providing control of the spatial frequency of the microscopic structures characteristic of the surface topography of the substrate. By combining single point diamond turning with subsequent electro-chemical etching, ultra smooth polishing of both rotationally symmetric and free form mirrors and molds is possible. Additionally, machining parameters can be set to optimize post polishing for increased surface quality and reduced processing times. In this work, we present a study of substrate surface finish based on diamond turning tool mark spatial frequency with subsequent electro-chemical polishing.
NASA Astrophysics Data System (ADS)
Kuska, Michalina; Augustyńska, Beata; Mikołajewska, Emilia; Mikołajewski, Dariusz
2017-11-01
Mobile solutions (smartphones, tablet computers, smartwatches, smartbands, gps locallzators, and associated software) become normal part of our daily activities. Thus novel part of e-commerce named m-tourism is developing rapidly. It may maximise profitability across national boundaries and make tourism easier, quicker and cheaper than before. We should be prepared to associated changes and novel economics. Aim of the article is to investigate factors associated with m-tourism experiences, and the association between use of e-services and tourism experiences and subsequent satisfaction.
Yoon, Hyung-In; Noh, Hyo-Mi; Park, Eun-Jin
2017-06-01
This study was to evaluate the effect of repeated ultrasonic scaling and surface polishing with intraoral polishing kits on the surface roughness of three different restorative materials. A total of 15 identical discs were fabricated with three different materials. The ultrasonic scaling was conducted for 20 seconds on the test surfaces. Subsequently, a multi-step polishing with recommended intraoral polishing kit was performed for 30 seconds. The 3D profiler and scanning electron microscopy were used to investigate surface integrity before scaling (pristine), after scaling, and after surface polishing for each material. Non-parametric Friedman and Wilcoxon signed rank sum tests were employed to statistically evaluate surface roughness changes of the pristine, scaled, and polished specimens. The level of significance was set at 0.05. Surface roughness values before scaling (pristine), after scaling, and polishing of the metal alloys were 3.02±0.34 µm, 2.44±0.72 µm, and 3.49±0.72 µm, respectively. Surface roughness of lithium disilicate increased from 2.35±1.05 µm (pristine) to 28.54±9.64 µm (scaling), and further increased after polishing (56.66±9.12 µm, P <.05). The zirconia showed the most increase in roughness after scaling (from 1.65±0.42 µm to 101.37±18.75 µm), while its surface roughness decreased after polishing (29.57±18.86 µm, P <.05). Ultrasonic scaling significantly changed the surface integrities of lithium disilicate and zirconia. Surface polishing with multi-step intraoral kit after repeated scaling was only effective for the zirconia, while it was not for lithium disilicate.
Noh, Hyo-Mi
2017-01-01
PURPOSE This study was to evaluate the effect of repeated ultrasonic scaling and surface polishing with intraoral polishing kits on the surface roughness of three different restorative materials. MATERIALS AND METHODS A total of 15 identical discs were fabricated with three different materials. The ultrasonic scaling was conducted for 20 seconds on the test surfaces. Subsequently, a multi-step polishing with recommended intraoral polishing kit was performed for 30 seconds. The 3D profiler and scanning electron microscopy were used to investigate surface integrity before scaling (pristine), after scaling, and after surface polishing for each material. Non-parametric Friedman and Wilcoxon signed rank sum tests were employed to statistically evaluate surface roughness changes of the pristine, scaled, and polished specimens. The level of significance was set at 0.05. RESULTS Surface roughness values before scaling (pristine), after scaling, and polishing of the metal alloys were 3.02±0.34 µm, 2.44±0.72 µm, and 3.49±0.72 µm, respectively. Surface roughness of lithium disilicate increased from 2.35±1.05 µm (pristine) to 28.54±9.64 µm (scaling), and further increased after polishing (56.66±9.12 µm, P<.05). The zirconia showed the most increase in roughness after scaling (from 1.65±0.42 µm to 101.37±18.75 µm), while its surface roughness decreased after polishing (29.57±18.86 µm, P<.05). CONCLUSION Ultrasonic scaling significantly changed the surface integrities of lithium disilicate and zirconia. Surface polishing with multi-step intraoral kit after repeated scaling was only effective for the zirconia, while it was not for lithium disilicate. PMID:28680550
Sharan, Smitha; Kavitha, H R; Konde, Harish; Kalahasti, Deepthi
2012-05-01
To evaluate the effect of chemical disinfectant on the transverse strength of heat-polymerized acrylic resins subjected to mechanical and chemical polishing. A total of 256 rectangular specimens (65 * 10 * 3 mm) 128 per resin (Lucitone-199 and Acralyn-H) were fabricated. One side of each specimen was not polished and the other was either mechanically (n = 96) or chemically (n = 96) polished and immersed for 10, 30 and 60 minutes in 2% alkaline glutaraldehyde. Mechanically polished (n = 32) and chemically polished (n = 32) control specimens were immersed only in distilled water. The transverse strength (N/mm(2)) was tested for failure in a universal testing machine, at a crosshead speed of 5 mm/min. Data were statistically analyzed using 2-way ANOVA and Student t-test. chemical polishing resulted in significantly lower transverse strength values than mechanical polishing. Lucitone- 199 resin demonstrated the highest overall transverse strength for the materials tested. Heat-polymerized acrylic resins either mechanically or chemically polished, did not demonstrate significant changes in transverse strength during immersion in the disinfecting solution tested, regardless of time of immersion. Lucitone-199 resin demonstrated the highest overall transverse strength for the materials tested and significantly stronger than Acralyn-H with either type of polishing following immersion in 2% alkaline glutaraldehyde. There is a concern that immersion in chemical solutions often used for cleansing and disinfection of prostheses may undermine the strength and structure of denture base resins. In this study it was observed that, the transverse strength of samples of Lucitone-199 was higher than that of the samples of Acralyn-H. The chances of fracture of the denture made of Lucitone-199 are less than that of dentures made of Acralyn-H. The chemically polished dentures may be more prone to fracture than mechanically polished dentures.
Acar, Burcu; Egilmez, Ferhan
2018-04-01
To investigate and compare the effects of several polishing systems and thermal cycling on the surface roughness and color change of various polymer-based CAD/CAM materials. Bar-shaped specimens (GC CeraSmart, CS; Lava Ultimate, LU and Vita Enamic, VE) were prepared. All specimens were polished with SiC papers. The specimens in Group A served as control and no additional surface polishing was applied. Final polishing was performed using diamond polishing paste (Diapolisher Paste) in Group B. In Group C, aluminum oxide abrasive discs (Sof-Lex XT Pop on) were used. Group D was polished with diamond impregnated spiral polishing system (EVE Diacomp Plus Twist). In Group E, polishing was done with rubber-based silicon abrasives (Polydentia). Thereafter, the specimens were submitted to thermal cycling. The surface roughness and color measurements were performed. Kruskal-Wallis and the Mann-Whitney U tests were applied for the evaluation of ΔE₀₀ data. Ra data were evaluated using three-way ANOVA. Pearson's correlation between Ra and ΔE₀₀ was further investigated. Neither the CAD/CAM materials nor thermal cycling affected the Ra data (P> 0.05). In contrast, significant difference was found among the polishing methods (P< 0.001). On the other hand, VE showed the highest color change whereas LU showed the lowest (P< 0.05). Additionally, the specimens in Group D exhibited significantly higher color change than other tested groups (P< 0.05). A moderate positive correlation was seen between Ra and ΔE₀₀ data of LU (rho = 0.390, P= 0.01). The diamond impregnated two-stage polishing procedure may not be an appropriate method for the tested CAD/CAM materials, as it resulted in the highest color change. On the other hand, all tested materials exhibited visually perceptible, but clinically acceptable color changes following the different polishing techniques. Additionally, diamond paste polishing could be a clinically acceptable procedure in terms of surface roughness. Copyright©American Journal of Dentistry.
Ferraris, Federico; Conti, Alessandro
2014-01-01
The following study asks three principle questions relative to composite finishing and composite polishing: 1) Will the superficial roughness of different restoration surfaces have different values, utilizing the same polishing system (multistep), after finishing with the tungsten carbide or diamond bur? 2) Under the same conditions of finishing and polishing sequences, will the composite surfaces (C), the composite-enamel (CE) and composite-dentin (CD) interfaces show different roughness values? 3) Will the surface roughness of composites of different translucency in the various phases of finishing and polishing, and on different interfaces, have different results? The null hypothesis is represented by the fact that there are no significant differences on roughness of composite restorations when polishing, after finishing with tungsten carbide or diamond burs. Furthermore, the null hypothesis is that there are no significant differences on roughness between polishing on composite surface, composite-enamel and composite-dentin interfaces, and finally there are no differences on roughness after finishing and polishing of two composite with different translucency. For the study, 56 class V cavities were prepared on extracted teeth. Restorations were done in nanofilled composite Filtek XTE (3M Espe) in a standard fashion, and then finished and polished. The 28 buccal cavities were restored on the surface with composite enamel and the 28 palatals with composite body. Finishing was done with fine toothing burs in tungsten carbide (16 blades) or fine grit diamond burs (46 μm), and made by the same manufacturer (Komet). The second phase of finishing was done with burs (with the same form as already mentioned) ultrafine toothing tungsten carbide (30 blades) or with extra and ultrafine grit diamond (25 and 8 μm). The polishing phase for both of the earlier sequences was done with the application of three rubber tips with decreasing abrasiveness and an application with a self-polishing brush. All measurements were taken from surfaces C, and interfaces CE and CD. Statistical analyses were carried out with c2 test (a = 0.05). 1) There were no relevant differences of surface roughness on the different surfaces if the polishing was done after finishing with tungsten carbide or diamond burs. 2) Keeping the same sequence of finishing and polishing, a difference was noticed between C, CE and CD, where the latter showed greater roughness. 3) Analyzing the data in all the phases of finishing and polishing on every interface, it can be concluded that the composite enamel and the composite body did not show different levels of superficial roughness. The clinical relevance could be resumed as follows: no difference after polishing, which is preceded by tungsten carbide or diamond finishing burs. The less favorable interface to be polished is CD, compared to CE and C. Considering two composites with different translucency, no difference on roughness after finishing and polishing were detected.
NASA Astrophysics Data System (ADS)
Pan, Jisheng; Yu, Peng; Yan, Qiusheng; Li, Weihua
2017-05-01
Strontium titanate (SrTiO3, STO) ceramic substrate is an incipient ferroelectric material with a perovskite structure and which has a wide range of applications in the fields of microwave, millimetre wave, and optic fibre. This paper reports on a system of experiments carried out on STO substrates using a new magnetorheological (MR) finishing process where dynamic magnetic fields are formed by magnetic poles rotate. The results show that a circular ring shaped polishing belt with a stability evaluation zone appears on the surface after being polished by MR finishing with a single-point dynamic magnetic field. The dynamic magnetic fields are stronger when the revolutions of magnetic pole increase and eccentricity of pole enlarge, with the surface finish is smoother and more material is removed. The optimum machining times, machining gap, oscillation distance, eccentricity of pole, revolutions of the workpiece and magnetic pole are 60 min, 0.8 mm, 0 mm, 7 mm, and 350 r min-1 and 90 r min-1, respectively, and the best MR fluid consists of 6 wt% of diamond abrasives in W1 particle size and 18 wt% of carbonyl iron powder in W3.5 particle size. A surface roughness of Ra and a material removal rate of 8 nm and 0.154 μm min-1 can be obtained in these optimum process conditions. Finally, the polishing mechanism for dynamic magnetic fields and the mechanism for removing material from STO ceramic substrates are discussed in detail.
NASA Astrophysics Data System (ADS)
Zhang, Yunfei; Huang, Wen; Zheng, Yongcheng; Ji, Fang; Xu, Min; Duan, Zhixin; Luo, Qing; Liu, Qian; Xiao, Hong
2016-03-01
Zinc sulfide is a kind of typical infrared optical material, commonly produced using single point diamond turning (SPDT). SPDT can efficiently produce zinc sulfide aspheric surfaces with micro-roughness and acceptable figure error. However the tool marks left by the diamond turning process cause high micro-roughness that degrades the optical performance when used in the visible region of the spectrum. Magnetorheological finishing (MRF) is a deterministic, sub-aperture polishing technology that is very helpful in improving both surface micro-roughness and surface figure.This paper mainly investigates the MRF technology of large aperture off-axis aspheric optical surfaces for zinc sulfide. The topological structure and coordinate transformation of a MRF machine tool PKC1200Q2 are analyzed and its kinematics is calculated, then the post-processing algorithm model of MRF for an optical lens is established. By taking the post-processing of off-axis aspheric surfacefor example, a post-processing algorithm that can be used for a raster tool path is deduced and the errors produced by the approximate treatment are analyzed. A polishing algorithm of trajectory planning and dwell time based on matrix equation and optimization theory is presented in this paper. Adopting this algorithm an experiment is performed to machining a large-aperture off-axis aspheric surface on the MRF machine developed by ourselves. After several times' polishing, the figure accuracy PV is proved from 3.3λ to 2.0λ and RMS from 0.451λ to 0.327λ. This algorithm is used to polish the other shapes including spheres, aspheres and prisms.
Whole-rock uranium analysis by fission track activation
NASA Technical Reports Server (NTRS)
Weiss, J. R.; Haines, E. L.
1974-01-01
We report a whole-rock uranium method in which the polished sample and track detector are separated in a vacuum chamber. Irradiation with thermal neutrons induces uranium fission in the sample, and the detector records the integrated fission track density. Detection efficiency and geometric factors are calculated and compared with calibration experiments.
A New Look at a Cause of Foreign Accent.
ERIC Educational Resources Information Center
Erazmus, Edward T.
1982-01-01
The theory of articulatory setting, originally published in 1964, is outlined and expanded on, drawing on experiences with Polish and English. The theory proposes that each language has a unique configuration of articulators accounting for or establishing the natural sounds of that language that give it phonological unity and differentiate it from…
Education for Persons with Special Needs: Polish and Russian Experience
ERIC Educational Resources Information Center
Valeeva, Roza A.; Kulesza, Ewa M.
2016-01-01
The beginning of the 21st century is marked by systemic, economic and social transformations in Poland and Russia, that significantly affected the education system, including the education for persons with special needs. This paper is an attempt to present synthetically the changes relating to persons with disabilities. The current state of the…
How Students "Stay the Course": Retention Practices in Higher Education
ERIC Educational Resources Information Center
Kurantowicz, Ewa; Nizinska, Adrianna
2013-01-01
The article is based on the results of research carried out under the RANLHE project in several Polish academic institutions. Applying the biographical research approach, the project aimed to explore and understand the access and retention-related experiences of non-traditional students. In a study of non-traditional students, three distinct…
Mountain Plains Learning Experience Guide: Appliance Repair. Course: Motor-Operated Appliances.
ERIC Educational Resources Information Center
Ziller, T.
One of two individualized courses included in an appliance repair curriculum, this course is designed to prepare students to operate, diagnose malfunctions, repair, and service motor operated appliances. The course is comprised of seven units: (1) Mixers and Blenders, (2) Vacuum Cleaners and Floor Polishers, (3) Washing Machines, (4) Garbage…
Educational and Social Inclusion of Handicapped Children. Polish Experiences
ERIC Educational Resources Information Center
Czyz, Anna
2016-01-01
This paper is dedicated to a very difficult and important subject--inclusion. Removing barriers, spreading social awareness and firmly established assistantship-guidance: these are the pillars by which inclusion is no longer an idea, but it becomes a process of creating a modern model of human functioning in the world. This pattern is primarily…
Shared Information Structure: Evidence from Cross-Linguistic Priming
ERIC Educational Resources Information Center
Fleischer, Zuzanna; Pickering, Martin J.; McLean, Janet F.
2012-01-01
This study asked whether bilinguals construct a language-independent level of information structure for the sentences that they produce. It reports an experiment in which a Polish-English bilingual and a confederate of the experimenter took turns to describe pictures to each other and to find those pictures in an array. The confederate produced a…
Higher Magnification Imaging of the Polished Aluminum Collector Returned from the Genesis Mission
NASA Technical Reports Server (NTRS)
Rodriquez, Melissa C.; Burkett, P. J.; Allton, J. H.
2011-01-01
The polished aluminum collector (previously referred to as the polished aluminum kidney) was intended for noble gas analysis for the Gene-sis mission. The aluminum collector, fabricated from alloy 6061T, was polished for flight with alumina, then diamond paste. Final cleaning was performed by soak-ing and rinsing with hexane, then isopropanol, and last-ly megasonically energized ultrapure water prior to installation. It was mounted inside the collector canister on the thermal shield at JSC in 2000. The polished aluminum collector was not surveyed microscopically prior to flight.
Method of fabricating a whispering gallery mode resonator
NASA Technical Reports Server (NTRS)
Savchenkov, Anatoliy A. (Inventor); Matkso, Andrey B. (Inventor); Iltchenko, Vladimir S. (Inventor); Maleki, Lute (Inventor)
2011-01-01
A method of fabricating a whispering gallery mode resonator (WGMR) is provided. The WGMR can be fabricated from a particular material, annealed, and then polished. The WGMR can be repeatedly annealed and then polished. The repeated polishing of the WGMR can be carried out using an abrasive slurry. The abrasive slurry can have a predetermined, constant grain size. Each subsequent polishing of the WGMR can use an abrasive slurry having a grain size that is smaller than the grain size of the abrasive slurry of the previous polishing iteration.
Prinke, Rafat T
2014-01-01
The translation of Chymiaphilosophica by Jakub Barner is the second publication in Polish historiography of a printed source work on early modem chemistry (alchemy) written by a Polish citizen, well known and influencial across Europe (the first such translation comprised the treatises of Michael Sendivogius). This admirable initiative of unquestionable value to Polish historians of science resulted in an elegantly published volume, with an extensive introduction and useful appendices. The language of the translation is pleasant to read, retaining the spirit of the original by means of a moderate use of archaisms and generally accurate selection of proper terminology. A closer comparison of some fragments of the translation reveals, however, that it omits essential words, phrases and even entire sentences. The translation itself is occasionally incorrect as well, completely changing the meaning of the author's text and distorting his intentions, thereby undermining the reliability of the Polish translation as a whole. In the factual layer, identifying both chemical substances and (especially) the names of the authors cited by Barner often appear to be doubtful or problematic. Apart from numerous obvious mistakes, as well as leaving many surnames unidentified even when it was very difficult, the translators and/or editors of the Polish text created some non-existent authors as a result of errors produced while copying their surnames from the original text or due to unfounded assumptions that some chemical or botanical terms are names of chemical authors. There is also no consistency in the spelling of surnames (usually left in the Latin form, sometimes spelled with wrong inflection, but also modernised). In the biographical introduction there are also numerous factual errors and some bizarre mistranslations. Not only did its author fail to correct invalid information of earlier biographers of Barner, relying only on the most obvious and accessible publications, but also perpetuated these "historiographical myths" and even created new ones. Neither did he consult any sources apart from some other of Barners published books. Writing from the positivist perspective and on the basis of outdated literature, he also sustained the categorical distinction between alchemy and chemistry, already rejected in contemporary historiography, thus presenting the role and position of Barner in the history of science not quite adequately. If one adds to that the very numerous "typos" throughout the book, it may be regarded as a negative example of poor source editing in almost every respect, even though it makes a pleasant reading.
Kilańska, D; Gaworska-Krzemińska, A; Grabowska, H; Gorzkowicz, B
2016-09-01
The development of a nursing practice, improvements in nurses' autonomy, and increased professional and personal responsibility for the medical services provided all require professional documentation with records of health status assessments, decisions undertaken, actions and their outcomes for each patient. The International Classification for Nursing Practice is a tool that meets all of these needs, and although it requires continuous evaluation, it offers professional documentation and communication in the practitioner and researcher community. The aim of this paper is to present a theoretical critique of an issue related to policy and experience of the current situation in Polish nursing - especially of the efforts to standardize nursing practices through the introduction and development of the Classification in Poland. Despite extensive promotion and training by International Council of Nurses members worldwide, there are still many countries where the Classification has not been implemented as a standard tool in healthcare facilities. Recently, a number of initiatives were undertaken in cooperation with the local and state authorities to disseminate the Classification in healthcare facilities. Thanks to intense efforts by the Polish Nurses Association and the International Council of Nurses Accredited Center for ICNP(®) Research & Development at the Medical University of Łódź, the Classification is known in Poland and has been tested at several centres. Nevertheless, an actual implementation that would allow for national and international interoperability requires strategic governmental decisions and close cooperation with information technology companies operating in the country. Discussing the barriers to the implementation of the Classification can improve understanding of it and its use. At a policy level, decision makers need to understand that use Classification in eHealth services and tools it is necessary to achieve interoperability. © 2016 International Council of Nurses.
Sharp, C; Randhawa, G
2016-04-01
In the United Kingdom, the demand for transplantable organs exceeds supply, leaving many patients on the active transplant waiting list with the majority on dialysis as the kidney is the most commonly transplanted organ. This is a marked issue across black, Asian, and minority ethnic communities. This article uses the Polish migrant community as a case study for making new theoretical insights into the willingness to become an organ donor in a host country using social capital theory. There were 31 participants who took part in interviews and small group discussions. Grounded theory methodology was used as the study explored the relationships between deceased organ donation, religion, and Mauss's gift-exchange theory and the notion of social capital arose as an emergent theme from the study. Elements of social capital were explored with participants such as social networks, civil engagement, trust, and reciprocity. Polish social networks were found to be small and the formation of networks to be influenced by English language skills. Participants were willing to donate organs to others inside and outside of their social networks in the United Kingdom and wanted to help a patient in need and influenced by the overall migrant experience in the United Kingdom and whether they felt a sense of belonging. Overall, participants had mixed experiences and views about trust in the National Health Service. Through a discussion of the results using a communitarian social capital, cognitive and structural social capital lens, and collective-action theory, it is concluded that an interplay of these social capital theories can reframe debates within organ donation such as reciprocity policies, the relevancy of altruism, and the role of migration experiences and networks in the willingness to donate organs posthumously in a host country. Copyright © 2016 Elsevier Inc. All rights reserved.
Effect finishing and polishing procedures on the surface roughness of IPS Empress 2 ceramic
Nishida, Rodrigo; Elossais, André Afif; Lima, Darlon Martins; Reis, José Mauricio Santos Nunes; Campos, Edson Alves; de Andrade, Marcelo Ferrarezi
2013-01-01
Objective. To evaluate the surface roughness of IPS Empress 2 ceramic when treated with different finishing/polishing protocols. Materials and methods. Sixteen specimens of IPS Empress 2 ceramic were made from wax patterns obtained using a stainless steel split mold. The specimens were glazed (Stage 0–S0, control) and divided into two groups. The specimens in Group 1 (G1) were finished/polished with a KG Sorensen diamond point (S1), followed by KG Sorensen siliconized points (S2) and final polishing with diamond polish paste (S3). In Group 2 (G2), the specimens were finished/polished using a Shofu diamond point (S1), as well as Shofu siliconized points (S2) and final polishing was performed using Porcelize paste (S3). After glazing (S0) and following each polishing procedure (S1, S2 or S3), the surface roughness was measured using TALYSURF Series 2. The average surface roughness results were analyzed using ANOVA followed by Tukey post-hoc tests (α = 0.01) Results. All of the polishing procedures yielded higher surface roughness values when compared to the control group (S0). S3 yielded lower surface roughness values when compared to S1 and S2. Conclusions. The proposed treatments negatively affected the surface roughness of the glazed IPS Empress 2 ceramic. PMID:22724660
Yoon, Byung Jo Victor; Xavier, Fred; Walker, Brendon R; Grinberg, Samuel; Cammisa, Frank P; Abjornson, Celeste
2016-10-01
Titanium plasma spray coating on polyetheretherketone (PEEK) is a recent innovation to interbody spacer technology. The inherent hydrophobic properties of standard, uncoated PEEK implants can hamper cell attachment and bone healing during fusion. The addition of titanium coating not only offers initial stability due to increased surface roughness but also long-term stability due to bony ongrowth created from osteoconductive microenvironment on the device surface. The previously established hydrophilic and osteophilic properties of commercially pure titanium (CPTi) can potentially provide an ideal environment promoting cell attachment and bony ongrowth when applied at the end plate level of the fusion site. Because the surface material composition and topography is what seems to directly affect cell adhesion, it is important to determine the ideal titanium coating for the highest effectiveness. The purpose of the study is to determine whether there is an optimal surface roughness for the titanium coatings and whether different polishing methods have a greater effect than roughness or topography in mediating cell adhesion to the surface. The study was divided into two phases. In Phase 1, the effects of varying surface roughnesses on identical polishing method were compared. In Phase 2, the effect of varying polishing methods was compared on identical surface roughnesses. Coating thickness, porosity, and surface roughness were characterized using an optical microscope as per ASTM F 1854 standards. For both phases, PEEK coupons with plasma-sprayed CPTi were used, and human mesenchymal stem cells (hMSCs) at an initial density of 25,000 cells/cm 2 were seeded and cultured for 24 hours before fixation in 10% formalin. The cultured hMSCs were visualized by 4',6-diamidino-2-phenylindole (DAPI) staining, a fluorescent stain that binds to the DNA of living cells. Samples were imaged using an environmental scanning electron microscope (eSEM) (Carl Zeiss Microscopy, Thornwood, NY, USA) using a backscattered detector. Image analysis of the CPTi coatings showed uniform and rough surfaces. For Phase 1, roughness was evaluated as fine, medium, and coarse. The eSEM image analysis and cell counting by DAPI demonstrated that hMSCs have a tendency to form stronger adhesion and greater pseudopodia extensions on fine roughness surfaces. Individual hMSCs were seen forming cytoplasmic processes extending across the width of a pore. There was a 4- and 20-fold reduction in adhered hMSCs with an increase to medium and coarse roughnesses, respectively. For Phase 2, studied groups are (1) medium CPTi coating with zirconia polishing, (2) medium CPTi coating with CPTi polishing, and (3) fine CPTi coating with CPTi polishing. The eSEM image analysis and cell counting by DAPI demonstrated that hMSCs have a tendency to form stronger adhesion and greater pseudopodia extensions on Group 3 over the other two groups. There was a twofold reduction in adhered hMSCs on medium roughness relative to fine. No difference in cell adhesion was found between Groups 1 and 2. Individual hMSCs were seen forming cytoplasmic processes extending across the width of a pore. Previously, it was accepted without much scrutiny that surface coatings were beneficial. This study begins to discover that surface topography directly affects the potential for cells to adhere and proliferate and lead to greater surgical efficacy. Copyright © 2016 Elsevier Inc. All rights reserved.
CRADA Final Report, 2011S003, Faraday Technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faraday Technologies
2012-12-12
This Phase I SBIR program addressed the need for an improved manufacturing process for electropolishing niobium RF superconducting cavities for the International Linear Collider (ILC). The ILC is a proposed particle accelerator that will be used to gain a deeper understanding of the forces of energy and matter by colliding beams of electrons and positrons at nearly the speed of light. The energy required for this to happen will be achieved through the use of advanced superconducting technology, specifically ~16,000 RF superconducting cavities operating at near absolute zero. The RF superconductor cavities will be fabricated from highly pure Nb, whichmore » has an extremely low surface resistance at 2 Kelvin when compared to other materials. To take full advantage of the superconducting properties of the Nb cavities, the inner surface must be a) polished to a microscale roughness < 0.1 µm with removal of at least 100 µm of material, and b) cleaned to be free of impurities that would degrade performance of the ILC. State-of-the-art polishing uses either chemical polishing or electropolishing, both of which require hydrofluoric acid to achieve breakdown of the strong passive film on the surface. In this Phase I program, Faraday worked with its collaborators at the Thomas Jefferson National Accelerator Facility (JLab) to demonstrate the feasibility of an electropolishing process for pure niobium, utilizing an environmentally benign alternative to chemical or electrochemical polishing electrolytes containing hydrofluoric acid. Faraday utilized a 31 wt% aqueous sulfuric acid solution (devoid of hydrofluoric acid) in conjunction with the FARADAYICSM Process, which uses pulse/pulse reverse fields for electropolishing, to demonstrate the ability to electropolish niobium to the desired surface finish. The anticipated benefits of the FARADAYICSM Electropolishing process will be a simpler, safer, and less expensive method capable of surface finishing high purity niobium cavities. Another potential benefit would be for the medical industry that uses hydrofluoric acid to electropolish niobium-alloy materials. The FARADAYICSM Electropolishing process will eliminate the environmental hazards posed by the use of hydrofluoric acid employed by chemical polishing and conventional electropolishing. Further, improved performance benefits may be possible. The overall objective of the Phase I program was to demonstrate that FARADAYIC Electropolishing of niobium cavities in electrolytes free of hydrofluoric acid can meet the RF superconducting performance criteria of those cavities. The FARADAYIC Electropolishing Process developed in the Phase I program was used to polish 50 mm Nb disks to a surface roughness (RA) of < 1 nm over a small area through process and post-processing optimization. An excellent level of surface cleanliness was achieved. While the desired 2K RF performance has not yet been achieved, Faraday believes that surface oxide state can be controlled through manipulation of the process parameters, to meet the 2K RF standard. Faraday is establishing apparatus and facilities infrastructure for single-cell SRF cavity electropolishing, through a synergistic effort with the Fermi National Accelerator Facility (Fermilab) to scale-up electropolishing of superconducting RF cavities. Faraday proposes to commercialize the subject technology via an IP based strategic relationship with a partner with established market channels within two primary commercialization avenues: 1) the superconducting particle accelerator community, 2) the medical device and implant market. Faraday will initially maintain Low Rate Initial Production capabilities for an application, but latterly seek a strategic partner who is solely dedicated to high rate production.« less
Nasoohi, Negin; Hoorizad, Maryam
2017-01-01
Objectives: This study aimed to assess the effect of wet and dry finishing and polishing on microhardness and roughness of microhybrid and nanohybrid composites. Materials and Methods: Thirty samples were fabricated of each of the Polofil Supra and Aelite Aesthetic All-Purpose Body microhybrid and Grandio and Aelite Aesthetic Enamel nanohybrid composite resins. Each group (n=30) was divided into three subgroups of D, W and C (n=10). Finishing and polishing were performed dry in group D and under water coolant in group W. Group C served as the control group and did not receive finishing and polishing. Surface roughness of samples was measured by a profilometer and their hardness was measured by a Vickers hardness tester. Data were analyzed using two-way ANOVA (P<0.05). Results: The smoothest surfaces with the lowest microhardness were obtained under Mylar strip without finishing/polishing for all composites (P<0.0001). The highest surface roughness was recorded for dry finishing/polishing for all composites (P<0.0001). Dry finishing/polishing increased the microhardness of all composites (P<0.0001). Conclusions: Dry finishing and polishing increases the microhardness and surface roughness of microhybrid and nanohybrid composite resins. PMID:29104597
New perspectives in hydrodynamic radial polishing techniques for optical surfaces
NASA Astrophysics Data System (ADS)
Ruiz, Elfego; Sohn, Erika; Luna, Esteban; Salas, Luis; Cordero, Alberto; González, Jorge; Núñez, Manuel; Salinas, Javier; Cruz-González, Irene; Valdés, Jorge; Cabrera, Victor; Martínez, Benjamín
2004-09-01
In order to overcome classic polishing techniques, a novel hydrodynamic radial polishing tool (HyDRa) is presented; it is useful for the corrective lapping and fine polishing of diverse materials by means of a low-cost abrasive flux and a hydrostatic suspension system that avoids contact of the tool with the working surface. This tool enables the work on flat or curved surfaces of currently up to two and a half meters in diameter. It has the advantage of avoiding fallen edges during the polishing process as well as reducing tool wear out and deformation. The functioning principle is based on the generation of a high-velocity, high-pressure, abrasive emulsion flux with radial geometry. The polishing process is repeatable by means of the control of the tool operational parameters, achieving high degrees of precision and accuracy on optical and semiconductor surfaces, with removal rates of up to 9 mm3/hour and promising excellent surface polishing qualities. An additional advantage of this new tool is the possibility to perform interferometric measurements during the polishing process without the need of dismounting the working surface. A series of advantages of this method, numerical simulations and experimental results are described.
Effect of slurry composition on the chemical mechanical polishing of thin diamond films
Werrell, Jessica M.; Mandal, Soumen; Thomas, Evan L. H.; Brousseau, Emmanuel B.; Lewis, Ryan; Borri, Paola; Davies, Philip R.; Williams, Oliver A.
2017-01-01
Nanocrystalline diamond (NCD) thin films grown by chemical vapour deposition have an intrinsic surface roughness, which hinders the development and performance of the films’ various applications. Traditional methods of diamond polishing are not effective on NCD thin films. Films either shatter due to the combination of wafer bow and high mechanical pressures or produce uneven surfaces, which has led to the adaptation of the chemical mechanical polishing (CMP) technique for NCD films. This process is poorly understood and in need of optimisation. To compare the effect of slurry composition and pH upon polishing rates, a series of NCD thin films have been polished for three hours using a Logitech Ltd. Tribo CMP System in conjunction with a polyester/polyurethane polishing cloth and six different slurries. The reduction in surface roughness was measured hourly using an atomic force microscope. The final surface chemistry was examined using X-ray photoelectron spectroscopy and a scanning electron microscope. It was found that of all the various properties of the slurries, including pH and composition, the particle size was the determining factor for the polishing rate. The smaller particles polishing at a greater rate than the larger ones. PMID:29057022
Effect of slurry composition on the chemical mechanical polishing of thin diamond films
NASA Astrophysics Data System (ADS)
Werrell, Jessica M.; Mandal, Soumen; Thomas, Evan L. H.; Brousseau, Emmanuel B.; Lewis, Ryan; Borri, Paola; Davies, Philip R.; Williams, Oliver A.
2017-12-01
Nanocrystalline diamond (NCD) thin films grown by chemical vapour deposition have an intrinsic surface roughness, which hinders the development and performance of the films' various applications. Traditional methods of diamond polishing are not effective on NCD thin films. Films either shatter due to the combination of wafer bow and high mechanical pressures or produce uneven surfaces, which has led to the adaptation of the chemical mechanical polishing (CMP) technique for NCD films. This process is poorly understood and in need of optimisation. To compare the effect of slurry composition and pH upon polishing rates, a series of NCD thin films have been polished for three hours using a Logitech Ltd. Tribo CMP System in conjunction with a polyester/polyurethane polishing cloth and six different slurries. The reduction in surface roughness was measured hourly using an atomic force microscope. The final surface chemistry was examined using X-ray photoelectron spectroscopy and a scanning electron microscope. It was found that of all the various properties of the slurries, including pH and composition, the particle size was the determining factor for the polishing rate. The smaller particles polishing at a greater rate than the larger ones.
Study of Profile Changes during Mechanical Polishing using Relocation Profilometry
NASA Astrophysics Data System (ADS)
Kumaran, S. Chidambara; Shunmugam, M. S.
2017-10-01
Mechanical polishing is a finishing process practiced conventionally to enhance quality of surface. Surface finish is improved by mechanical cutting action of abrasive particles on work surface. Polishing is complex in nature and research efforts have been focused on understanding the polishing mechanism. Study of changes in profile is a useful method of understanding behavior of the polishing process. Such a study requires tracing same profile at regular process intervals, which is a tedious job. An innovative relocation technique is followed in the present work to study profile changes during mechanical polishing of austenitic stainless steel specimen. Using special locating fixture, micro-indentation mark and cross-correlation technique, the same profile is traced at certain process intervals. Comparison of different parameters of profiles shows the manner in which metal removal takes place in the polishing process. Mass removal during process estimated by the same relocation technique is checked with that obtained using weight measurement. The proposed approach can be extended to other micro/nano finishing processes and favorable process conditions can be identified.
Heiden, Michael; Huang, Sabrina; Nauman, Eric; Johnson, David; Stanciu, Lia
2016-07-01
Nanostructured Fe-Mn and Fe-Mn-Zn metal scaffolds were generated through a well-controlled selective leaching process in order to fulfill the growing demand for adjustable degradation rates and improved cellular response of resorbable materials. Mouse bone marrow mesenchymal stem cells (D1 ORL UVA) were seeded onto eleven, carefully chosen nanoporous surfaces for 24 h in vitro. Using a combination of fluorescence microscopy, scanning electron microscopy (SEM), and an MTS assay, it was discovered that scaffolds with nanoscale roughened surfaces had increased cell attachment by up to 123% compared to polished smooth Fe-Mn surfaces. Significant cell spreading and construction of cell multilayers were also apparent after 24 h, suggesting better adhesion. Additionally, static electrochemical polarization experiments revealed an improvement of up to 26% in the actual rate of biodegradation for Fe-Mn surface-modified materials. However, any residual concentration of zinc after leaching was shown to slightly increase corrosion resistance. The results demonstrate that selectively leached, nanostructured Fe-Mn surfaces have the potential of being tailored to a diverse set of transient implant scenarios, while also effectively boosting overall biocompatibility, initial cell attachment, and degradation rate. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1747-1758, 2016. © 2016 Wiley Periodicals, Inc.
Subacromial bursitis with giant rice bodies as initial presentation of rheumatoid arthritis.
Subramaniam, Ramesh; Tan, Justina Wei Lyn; Chau, Cora Yuk Ping; Lee, Keng Thiam
2012-10-01
Rice body formation is a nonspecific response to chronic synovial inflammation associated with tuberculous arthritis, rheumatoid arthritis, juvenile rheumatoid arthritis, seronegative inflammatory arthritis, and even osteoarthritis. Such bodies were termed rice bodies because of their close resemblance to grains of polished white rice. We present a case report of a middle-aged woman with right shoulder subacromial/subdeltoid bursitis with giant rice body formation as her initial presentation of rheumatoid arthritis. Her right shoulder symptoms resolved after subacromial and subdeltoid bursectomy and removal of the rice bodies. She subsequently developed inflammatory arthritis of other joints, met the criteria for rheumatoid arthritis, and has been treated medically.
Gardosian Patterns in Tribology
NASA Technical Reports Server (NTRS)
DellaCorte, Christopher
2004-01-01
The following paper is a memorial retrospective on selected research of Dr. Michael N. Gardos. Dr. Gardos spent his professional career engaged in tribological research which often extended the scientific boundaries of the field. Several of the concepts he put forth into the tribology community were initially met with grave skepticism but over time his views have been largely embraced but not widely acknowledged. His approach to new research topics was often characterized by these qualities: 1) pioneering points of view, 2) the use of the model experiment, and 3) the presence of multiple research agendas for each single experiment. I have chosen to name his research approach as "Gardosian Patterns" in honor of his contributions to Tribology. Three specific examples of these patterns will be reviewed. One is the concept of atomic level tailoring of materials to control macroscopic properties. A second is the use of a model ball polishing experiment to identify high fracture toughness ceramics for use in rolling element bearings. A third Gardosian Pattern example is his pioneering work with the tribology of diamond and diamond films in which he proposed controlling friction via surface bond tailoring. In these examples, Gardos utilized conventional research tools in unconventional ways and, at times, even developed new tools which have become part of the mainstream. His remarkable career has left a positive and lasting mark on Tribology.
Sabbat, J
1997-09-01
The restoration of democracy in Poland initiated a major system transformation including reform of the health sector. The international community were quick to respond to the need for assistance. Polish proposals were supported by international experts and projects were developed together with international development agencies and donors. Donors had no experience of central and eastern Europe, these countries had never been beneficiaries of aid and neither side had experience working together. Progress and absorption of funds was slow. Comparative experience from developing countries was used to analyze the barriers encountered in project development and implementation in Poland. The conditions necessary for implementation were not satisfied. Insufficient attention was paid to the project process. Barriers originate on the side of both donors and recipients and additionally from programme characteristics. The most serious problems experience in Poland were lack of government commitment to health care reform leading to failure to provide counterpart funds and low capacity for absorption of aid. Rent seeking attitudes were important. Donor paternalistic attitudes, complex procedures and lack of innovative approach were also present. Poor coordination was a problem on both sides. Multi-lateral projects were too complex and it was not always possible to integrate project activities with routine ones. External consultants played an excessive role in project development and implementation, absorbing a large portion of funds. The barriers have been operationalised to create a checklist which requires validation elsewhere and may be useful for those working in this field.
Czachowski, Slawomir; Pawlikowska, Teresa
2011-08-01
The establishment of family medicine (FM) in Poland following political reform. To describe family doctors' (FD) experiences during the introduction of FM. A qualitative study of 25 FDs in Poland, using thematic analysis of semi-structured interviews. Open-structured narrative-based interviews with five FDs were then used to deepen understanding of the major emergent themes. Fifteen of 25 had a different initial specialization to FM; 10 of 25 overseas work experience. Many doctors were driven by personal circumstances to engage with this new discipline, which provided a better fit with their life circumstances and a chance to escape from hierarchical structures characterizing the old regime. Personal experience of role models helped embrace FM, whereas adherence to ingrained biomedical approaches led to difficulty with exposure to common problems and could facilitate burnout. Shifting relationships in the reformed system caused tensions between primary and secondary care. While relationships with patients and specialists were being renegotiated, the concept of an independent FD practice surfaced. We observed that the most serious problems that the doctors encountered were circumstances related to the former health care system, in contrast to any lack of professional skills. This is a rare qualitative study exploring Polish doctors' perspectives of the health care reform after the collapse of communism in Central and Eastern Europe. This analysis of newly qualified FDs has provided an insight into the authentic experiences, and motivation of grass roots FM pioneers in Poland.
21 CFR 872.6030 - Oral cavity abrasive polishing agent.
Code of Federal Regulations, 2013 CFR
2013-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...
21 CFR 872.6030 - Oral cavity abrasive polishing agent.
Code of Federal Regulations, 2012 CFR
2012-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...
21 CFR 872.6030 - Oral cavity abrasive polishing agent.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...
21 CFR 872.6030 - Oral cavity abrasive polishing agent.
Code of Federal Regulations, 2011 CFR
2011-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...
21 CFR 872.6030 - Oral cavity abrasive polishing agent.
Code of Federal Regulations, 2014 CFR
2014-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suzuki, N.; Miyamaru, K.
1995-03-01
The new TEPCO BWR`s are capable of having the occupational radiation exposure controlled successfully at a low level by selecting low cobalt steel, using corrosion-resistant steel, employing dual condensate polishing systems, and controlling Ni/Fe ratio during operation. The occupational radiation exposure of the old BWR`s, on the other hand, remains high though reduced substantially through the use of low cobalt replacement steel and the partial addition of a filter in the condensate polishing system. Currently under review is the overall decontamination procedure for the old BWR`s to find out to measures needed to reduce the amount of crud that ismore » and has been carried over into the nuclear reactor. The current status of decontamination is reported below.« less
Magnetorheological Finishing for Imprinting Continuous Phase Plate Structure onto Optical Surfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menapace, J A; Dixit, S N; Genin, F Y
2004-01-05
Magnetorheological finishing (MRF) techniques have been developed to manufacture continuous phase plates (CPP's) and custom phase corrective structures on polished fused silica surfaces. These phase structures are important for laser applications requiring precise manipulation and control of beam-shape, energy distribution, and wavefront profile. The MRF's unique deterministic-sub-aperture polishing characteristics make it possible to imprint complex topographical information onto optical surfaces at spatial scale-lengths approaching 1 mm. In this study, we present the results of experiments and model calculations that explore imprinting two-dimensional sinusoidal structures. Results show how the MRF removal function impacts and limits imprint fidelity and what must bemore » done to arrive at a high quality surface. We also present several examples of this imprinting technology for fabrication of phase correction plates and CPPs for use at high fluences.« less
Enclosed Cutting-And-Polishing Apparatus
NASA Technical Reports Server (NTRS)
Rossier, R. N.; Bicknell, B.
1989-01-01
Proposed apparatus cuts and polishes specimens while preventing contamination of outside environment or of subsequent specimens processed in it. Designed for use in zero gravity but also includes features useful in cutting and polishing of toxic or otherwise hazardous materials on Earth. Includes remote manipulator for handling specimens, cutting and polishing wire, inlets for gas and liquid, and outlets for waste liquid and gas. Replaceable plastic liner surrounds working space.
Design Considerations of Polishing Lap for Computer-Controlled Cylindrical Polishing Process
NASA Technical Reports Server (NTRS)
Khan, Gufran S.; Gubarev, Mikhail; Arnold, William; Ramsey, Brian D.
2009-01-01
This paper establishes a relationship between the polishing process parameters and the generation of mid spatial-frequency error. The consideration of the polishing lap design to optimize the process in order to keep residual errors to a minimum and optimization of the process (speeds, stroke, etc.) and to keep the residual mid spatial-frequency error to a minimum, is also presented.
Paravina, Rade D; Roeder, Leslie; Lu, Huan; Vogel, Karin; Powers, John M
2004-08-01
To evaluate the effects of different finishing and polishing procedures on surface roughness, gloss and color of five resin composites: two experimental microhybrid composites - FZ-Dentin (FZD) and FZ-Enamel (FZE), one commercial microhybrid composite - Esthet-X (EX), and two microfilled composites - Heliomolar (HM) and Renamel Microfill (RM). Surface roughness, gloss and color of the disc-shaped specimens (10 mm in diameter and 2-mm thick) were measured as Mylar (baseline), 16-fluted carbide bur and polishing were completed. Sixteen specimens of each composite were randomized to four groups of four. After finishing with a 16-fluted finishing bur, each group was polished by a different system: 1. Astropol (A), 2. Sof-lex disc (S), 3. Po-Go (P), 4. Enhance (E). Average surface roughness (Ra) was measured with a profilometer. Gloss measurements were performed using small-area glossmeter, while color coordinate values were recorded using a spectrophotometer. A deltaE*ab< or =1 was considered to be the limit of perceptibility. The order of surface roughness ranked according to polishing system (for all five composites together) was: P < S < E < A. The order of surface roughness ranked according to composites was: RM < FZD < FZ < HM < EX. The order of gloss ranked according to polishing system (for all five composites together) was: P > E > A > S. The order of gloss values for the polished composites (for each of four polishing systems) was: RM > FZD > FZE > HM > EX. Fisher's PLSD intervals at the 0.05 level of significance for comparisons of means of surface roughness among five composites and four polishing systems were 0.01 and 0.01 microm, respectively. Fisher's PLSD intervals at the 0.05 level of significance for comparisons of means of gloss among five composites and four polishing systems were 6 and 5 GU, respectively. Color differences (deltaE*ab) among five composites and four polishing methods were found to range from 0.2 to 1.1.
Designable ultra-smooth ultra-thin solid-electrolyte interphases of three alkali metal anodes.
Gu, Yu; Wang, Wei-Wei; Li, Yi-Juan; Wu, Qi-Hui; Tang, Shuai; Yan, Jia-Wei; Zheng, Ming-Sen; Wu, De-Yin; Fan, Chun-Hai; Hu, Wei-Qiang; Chen, Zhao-Bin; Fang, Yuan; Zhang, Qing-Hong; Dong, Quan-Feng; Mao, Bing-Wei
2018-04-09
Dendrite growth of alkali metal anodes limited their lifetime for charge/discharge cycling. Here, we report near-perfect anodes of lithium, sodium, and potassium metals achieved by electrochemical polishing, which removes microscopic defects and creates ultra-smooth ultra-thin solid-electrolyte interphase layers at metal surfaces for providing a homogeneous environment. Precise characterizations by AFM force probing with corroborative in-depth XPS profile analysis reveal that the ultra-smooth ultra-thin solid-electrolyte interphase can be designed to have alternating inorganic-rich and organic-rich/mixed multi-layered structure, which offers mechanical property of coupled rigidity and elasticity. The polished metal anodes exhibit significantly enhanced cycling stability, specifically the lithium anodes can cycle for over 200 times at a real current density of 2 mA cm -2 with 100% depth of discharge. Our work illustrates that an ultra-smooth ultra-thin solid-electrolyte interphase may be robust enough to suppress dendrite growth and thus serve as an initial layer for further improved protection of alkali metal anodes.
The unwanted heroes: war invalids in Poland after World War I.
Magowska, Anita
2014-04-01
This article focuses on the unique and hitherto unknown history of disabled ex-servicemen and civilians in interwar Poland. In 1914, thousands of Poles were conscripted into the Austrian, Prussian, and Russian armies and forced to fight against each other. When the war ended and Poland regained independence after more than one hundred years of partition, the fledgling government was unable to provide support for the more than three hundred thousand disabled war victims, not to mention the many civilians left injured or orphaned by the war. The vast majority of these victims were ex-servicemen of foreign armies, and were deprived of any war compensation. Neither the Polish government nor the impoverished society could meet the disabled ex-servicemen's medical and material needs; therefore, these men had to take responsibility for themselves and started cooperatives and war-invalids-owned enterprises. A social collaboration between Poland and America, rare in Europe at that time, was initiated by the Polish community in the United States to help blind ex-servicemen in Poland.
Da Costa, Juliana; Ferracane, Jack; Paravina, Rade D; Mazur, Rui Fernando; Roeder, Leslie
2007-01-01
The purpose of this in vitro study was to evaluate the surface finish and gloss of five direct resin composites polished with six polishing systems. One hundred and fifty disk-shaped composite specimens (D=10.0 mm, 2-mm-thick, N=30 per material) were made. One side of each specimen was finished with a 16-fluted carbide finishing bur and then polished. Five specimens of each resin composite were randomly assigned to one of the six polishing systems. The surface roughness and gloss were measured with a surface profilometer and a glossmeter. The results were analyzed by two-way analysis of variance and Tukey's t-test (p
[The life of Polish students at the Polish School of Medicine at the University of Edinburgh].
Gebertt, S
1994-01-01
The article has been written by a former student of the Polish School of Medicine at the University of Edinburgh, a member of the Polish Forces in Britain. The reminiscences concentrate on day to day life of others, like himself, seconded from the Forces to continue their medical studies. Statistical data concerning the activities of Polish School of Medicine are presented and analysed. Detailed mention is made of various routes by which Polish students reached Great Britain from the time of defeat and partition of Poland between Germany and Soviet Union. The various phases of relationship and attitudes between Polish Armed Forces and the body of students are described and illustrated by extracts from personal memoirs. The number of other topics is presented and discussed: The difficulties and problems encountered in living and studying amongst people, who although sympathetic, but whose language, culture and customs were completely foreign to the Poles. The ways in which individuals and groups of students tried and in many instances managed to overcome these obstacles, forging links with their Scottish colleagues and population at large. The participation in various joint activities like Settlement Day, work in agricultural camps, sports, Scottish students Unions and Representative Councils etc. are described. "Inner life" of Polish students concentrated in "Bursa" (an equivalent of University Residence) is presented in a light-hearted way. Large detachments of a foreign army, living, amongst albeit friendly population, are bound to cause, sometimes serious, friction. Very much in relation to this problem the role of Polish students as ambassadors of Poland and Polish Causes are presented and their value assessed.
Freddo, Rafael Augusto; Kapczinski, Myriam Pereira; Kinast, Eder Julio; de Souza Junior, Oswaldo Baptista; Rivaldo, Elken Gomes; da Fontoura Frasca, Luis Carlos
2016-10-01
To evaluate, by means of pin-on-disk testing, the wear potential of different dental ceramic systems as it relates to friction parameters, surface finish, and microhardness. Three groups of different ceramic systems (Noritake EX3, Eris, Empress II) with 20 disks each (10 glazed, 10 polished) were used. Vickers microhardness (Hv) was determined with a 200-g load for 30 seconds. Friction coefficients (μ) were determined by pin-on-disk testing (5 N load, 600 seconds, and 120 rpm). Wear patterns were assessed by scanning electron microscopy (SEM). The results were analyzed using one-way ANOVA and Tukey's test, with the significance level set at α = 0.05. The coefficients of friction were as follows: Noritake EX3 0.28 ± 0.12 (polished), 0.33 ± 0.08 (glazed); Empress II 0.38 ± 0.08 (polished), 0.45 ± 0.05 (glazed); Eris 0.49 ± 0.05 (polished), 0.49 ± 0.06 (glazed). Microhardness measurements were as follows: Noritake EX3 530.7 ± 8.7 (polished), 525.9 ± 6.2 (glazed); Empress II 534.1 ± 8 (polished), 534.7 ± 4.5 (glazed); Eris, 511.7 ± 6.5 (polished), 519.5 ± 4.1 (glazed). The polished and glazed Noritake EX3 and polished and glazed Eris specimens showed statistically different friction coefficients. SEM image analysis revealed more surface changes, such as small cracks and grains peeling off, in glazed ceramics. Wear potential may be related to the coefficient of friction in Noritake ceramics, which had a lower coefficient than Eris ceramics. Within-group analysis showed no differences in polished or glazed specimens. The differences observed were not associated with microhardness. © 2015 by the American College of Prosthodontists.
Narloch, Jerzy; Glinkowska, Bożena; Bandura, Małgorzata
2016-01-01
Introduction Patients diagnosed before the Polish FRAX was introduced may require re-evaluation and treatment changes if the diagnosis was established according to a surrogate country FRAX score. The aim of the study was to evaluate the validity of treatment decisions based on the surrogate country model before introduction of the Polish FRAX and to provide recommendations based on the current practice. Material and methods We evaluated a group of 142 postmenopausal women (70.7 ±8.9 years) who underwent bone mineral density measurements. We used 22 country-specific FRAX models and compared these to the Polish model. Results The mean risk values for hip and major osteoporotic fractures within 10 years were 4.575 (from 0.82 to 8.46) and 12.47% (from 2.18 to 21.65), respectively. In the case of a major fracture, 94.4% of women would receive lifestyle advice, and 5.6% would receive treatment according to the Polish FRAX using the guidelines of the National Osteoporosis Foundation (NOF). Polish treatment thresholds would implement pharmacotherapy in 32.4% of the study group. In the case of hip fractures, 45% of women according to the NOF would require pharmacotherapy but only 9.8% of women would qualify according to Polish guidelines. Nearly all surrogate FRAX calculator scores proved significantly different form Polish (p > 0.05). Conclusions More patients might have received antiresorptive medication before the Polish FRAX. This study recommends re-evaluation of patients who received medical therapy before the Polish FRAX was introduced and a review of the recommendations, considering the side effects of antiresorptive medication. PMID:29593808
Glinkowski, Wojciech M; Narloch, Jerzy; Glinkowska, Bożena; Bandura, Małgorzata
2018-03-01
Patients diagnosed before the Polish FRAX was introduced may require re-evaluation and treatment changes if the diagnosis was established according to a surrogate country FRAX score. The aim of the study was to evaluate the validity of treatment decisions based on the surrogate country model before introduction of the Polish FRAX and to provide recommendations based on the current practice. We evaluated a group of 142 postmenopausal women (70.7 ±8.9 years) who underwent bone mineral density measurements. We used 22 country-specific FRAX models and compared these to the Polish model. The mean risk values for hip and major osteoporotic fractures within 10 years were 4.575 (from 0.82 to 8.46) and 12.47% (from 2.18 to 21.65), respectively. In the case of a major fracture, 94.4% of women would receive lifestyle advice, and 5.6% would receive treatment according to the Polish FRAX using the guidelines of the National Osteoporosis Foundation (NOF). Polish treatment thresholds would implement pharmacotherapy in 32.4% of the study group. In the case of hip fractures, 45% of women according to the NOF would require pharmacotherapy but only 9.8% of women would qualify according to Polish guidelines. Nearly all surrogate FRAX calculator scores proved significantly different form Polish ( p > 0.05). More patients might have received antiresorptive medication before the Polish FRAX. This study recommends re-evaluation of patients who received medical therapy before the Polish FRAX was introduced and a review of the recommendations, considering the side effects of antiresorptive medication.
Skovager, Anne; Whitehead, Kathryn; Wickens, David; Verran, Joanna; Ingmer, Hanne; Arneborg, Nils
2013-09-01
Magnetron sputtering was used to produce nanocomposite TiN and TiN/Ag coatings on stainless steel surfaces. The surface chemistry (EDX), physicochemical properties (contact angles), topography and roughness parameters (WLP and AFM) of the fine polished stainless steel (FPSS), TiN and TiN/8.6 at.% Ag surfaces were examined. Real-time initial adhesion of two Listeria monocytogenes strains (EGDe and 64) to the three surfaces was determined under flow conditions, and their attachment strength after adhesion was measured using atomic force microscopy (AFM). The anti-listerial properties of the surfaces were determined using LIVE/DEAD staining. Our results demonstrate that FPSS, TiN and TiN/8.6 at.% Ag possessed different surface properties, which may influence both attachment strength and anti-listerial properties. There were no significant (p>0.05) differences in the initial adhesion of the two L. monocytogenes strains to the three different surfaces. Attachment studies showed that the two L. monocytogenes strains did not attach to FPSS under wetted conditions. However, both strains attached to TiN and TiN/8.6 at.% Ag surfaces, although with less strength to TiN/8.6 at.% Ag than to TiN surfaces. The TiN/8.6 at.% Ag surface showed marked anti-listerial properties as compared with FPSS and TiN. Initial adhesion, attachment strength and anti-listerial properties were found to be strain dependent. Copyright © 2013 Elsevier B.V. All rights reserved.
Williamson Polishing & Plating Site
Williamson Polishing & Plating Co. Inc. was a plating shop located in the Martindale-Brightwood neighborhood of Indianapolis. The facility conducted job shop polishing and electroplating services. The vacant site contains a 14,651-square-foot building.
Lacerda, Vánia A; Pereira, Leandro O; Hirata JUNIOR, Raphael; Perez, Cesar R
2015-12-01
To evaluate the effectiveness of disinfection/sterilization methods and their effects on polishing capacity, micomorphology, and composition of two different composite fiishing and polishing instruments. Two brands of finishing and polishing instruments (Jiffy and Optimize), were analyzed. For the antimicrobial test, 60 points (30 of each brand) were used for polishing composite restorations and submitted to three different groups of disinfection/sterilization methods: none (control), autoclaving, and immersion in peracetic acid for 60 minutes. The in vitro tests were performed to evaluate the polishing performance on resin composite disks (Amelogen) using a 3D scanner (Talyscan) and to evaluate the effects on the points' surface composition (XRF) and micromorphology (MEV) after completing a polishing and sterilizing routine five times. Both sterilization/disinfection methods were efficient against oral cultivable organisms and no deleterious modification was observed to point surface.
ERIC Educational Resources Information Center
Gregory, E.; Lytra, V.; Choudhury, H.; Ilankuberan, A.; Kwapong, A.; Woodham, M.
2013-01-01
In this paper, we illustrate how young children from four faith communities (Tamil Hindu/Saiva, Bangladeshi Muslim, Polish Catholic and Ghanaian Pentecostal) new to London bring together and juxtapose an array of different languages, literacies, learning and discourse styles, communicative resources and experience to create unique personal…
Gloss and surface roughness produced by polishing kits on resin composites.
Sadidzadeh, Ramtin; Cakir, Deniz; Ramp, Lance C; Burgess, John O
2010-08-01
To compare in vitro the surface roughness (Ra) and gloss (G) produced by three conventional and one experimental polishing kits on four resin composites. 24 discs were prepared (d = 12 mm, t = 4 mm) for each resin composite: Filtek Supreme Plus Body/A2 (FSB), Yellow Translucent (FST), Heliomolar/A2 (HM), and EsthetX/A2 (EX) following the manufacturers' instructions. They were finished with 320 grit silicon carbide paper for 80 seconds each. Polishing systems: Sof-Lex, Enhance-Pogo, Astropol and Experimental Discs/EXL-695, were applied following manufacturers' instructions. Each specimen was ultrasonically cleaned with distilled water and dried. Gloss and Ra were measured with a small area glossmeter (Novo-curve) and non-contact profilometer (Proscan 2000) following ISO 4288, respectively. The results were evaluated by two-way ANOVA followed by separate one-way ANOVA and Tukey/Kramer test (P = 0.05). There was a significant interaction of surface roughness and gloss between the composites and polishing systems (P < 0.05). The lowest surface roughness was recorded for FST polished with the Experimental kit. The highest gloss was obtained for FSB composite polished with the Experimental kit. The experimental polishing system produced smoothest surfaces (P < 0.05). The Enhance-Pogo and the experimental polishing kit produced highest gloss (P < 0.05).
Fabrication of an optical component
Nichols, Michael A.; Aikens, David M.; Camp, David W.; Thomas, Ian M.; Kiikka, Craig; Sheehan, Lynn M.; Kozlowski, Mark R.
2000-01-01
A method for forming optical parts used in laser optical systems such as high energy lasers, high average power lasers, semiconductor capital equipment and medical devices. The optical parts will not damage during the operation of high power lasers in the ultra-violet light range. A blank is first ground using a fixed abrasive grinding method to remove the subsurface damage formed during the fabrication of the blank. The next step grinds and polishes the edges and forms bevels to reduce the amount of fused-glass contaminants in the subsequent steps. A loose abrasive grind removes the subsurface damage formed during the fixed abrasive or "blanchard" removal process. After repolishing the bevels and performing an optional fluoride etch, the surface of the blank is polished using a zirconia slurry. Any subsurface damage formed during the loose abrasive grind will be removed during this zirconia polish. A post polish etch may be performed to remove any redeposited contaminants. Another method uses a ceria polishing step to remove the subsurface damage formed during the loose abrasive grind. However, any residual ceria may interfere with the optical properties of the finished part. Therefore, the ceria and other contaminants are removed by performing either a zirconia polish after the ceria polish or a post ceria polish etch.
Leite, Brisa Dos Santos; Fagundes, Nathalia Carolina Fernandes; Aragón, Mônica Lídia Castro; Dias, Carmen Gilda Barroso Tavares; Normando, David
2016-01-01
Debris buildup on the bracket-wire interface can influence friction. Cleansing brackets with air-powder polishing can affect this process. The aim of this study was to evaluate the frictional force and amount of debris remaining on orthodontic brackets subjected to prophylaxis with air-powder polishing. Frictional force and debris buildup on the surface of 28 premolar brackets were evaluated after orthodontic treatment. In one hemiarch, each bracket was subjected to air-powder polishing (n = 14) for five seconds, while the contralateral hemiarch (n = 14) served as control. Mechanical friction tests were performed and images of the polished bracket surfaces and control surfaces were examined. Wilcoxon test was applied for comparative analysis between hemiarches at p < 0.05. Brackets that had been cleaned with air-powder polishing showed lower friction (median = 1.27 N) when compared to the control surfaces (median = 4.52 N) (p < 0.01). Image analysis showed that the control group exhibited greater debris buildup (median = 2.0) compared with the group that received prophylaxis with air-powder polishing (median = 0.5) (p < 0.05). Cleansing orthodontic brackets with air-powder polishing significantly reduces debris buildup on the bracket surface while decreasing friction levels observed during sliding mechanics.
Interferometric analysis of polishing surface with a petal tool
NASA Astrophysics Data System (ADS)
Salas-Sánchez, Alfonso; Leal-Cabrera, Irce; Percino Zacarias, Elizabeth; Granados-Agustín, Fermín S.
2011-09-01
In this work, we describe a phase shift interferometric monitoring of polishing processes produced by a petal tool over a spherical surface to obtain a parabolic surface. In the process, we used a commercial polishing machine; the purpose of this work is to have control of polishing time. To achieve this analysis, we used a Fizeau interferometer of ZYGO Company for optical shop testing, and the Durango software from Diffraction International Company. For data acquisition, simulation and evaluation of optical surfaces, we start polishing process with a spherical surface with 15.46 cm of diameter; a 59.9 cm of radius curvature and, with f/# 1.9.
Centre for Research Infrastructure of Polish GNSS Data - response and possible contribution to EPOS
NASA Astrophysics Data System (ADS)
Araszkiewicz, Andrzej; Rohm, Witold; Bosy, Jaroslaw; Szolucha, Marcin; Kaplon, Jan; Kroszczynski, Krzysztof
2017-04-01
In the frame of the first call under Action 4.2: Development of modern research infrastructure of the science sector in the Smart Growth Operational Programme 2014-2020 in the late of 2016 the "EPOS-PL" project has launched. Following institutes are responsible for the implementation of this project: Institute of Geophysics, Polish Academy of Sciences - Project Leader, Academic Computer Centre Cyfronet AGH University of Science and Technology, Central Mining Institute, the Institute of Geodesy and Cartography, Wrocław University of Environmental and Life Sciences, Military University of Technology. In addition, resources constituting entrepreneur's own contribution will come from the Polish Mining Group. Research Infrastructure EPOS-PL will integrate both existing and newly built National Research Infrastructures (Theme Centre for Research Infrastructures), which, under the premise of the program EPOS, are financed exclusively by the national founds. In addition, the e-science platform will be developed. The Centre for Research Infrastructure of GNSS Data (CIBDG - Task 5) will be built based on the experience and facilities of two institutions: Military University of Technology and Wrocław University of Environmental and Life Sciences. The project includes the construction of the National GNNS Repository with data QC procedures and adaptation of two Regional GNNS Analysis Centres for rapid and long-term geodynamical monitoring.
Kumari, R Veena; Nagaraj, Hema; Siddaraju, Kishore; Poluri, Ramya Krishna
2015-01-01
Background: It is beyond doubt that finishing and polishing of a composite restoration enhance its esthetics and, is also essential for the health of the periodontium. A variety of instruments are commonly used for finishing and polishing tooth-colored restorative materials Thus, it is important to understand which type of surface finishing treatments would significantly affect the staining and surface irregularities of the composite resin restoration. Still one of the properties of the composite resins that have to pass the test of time is its color stability. In modern day dentistry, a large emphasis is laid over esthetics. Hence, it is important to understand the various agents capable of adversely affecting the esthetics of a restoration due to its staining capacity. Thus, the aim of this in vitro study was to evaluate the effect of surface polishing, oral beverages and food colorants on the color stability and surface roughness of nanocomposite resins. Materials and Methods: 90 Disks of nanocomposites resin (Filtek Z350 XT) measuring 8 mm in diameter and 2 mm in thickness were fabricated using a custom made silicon mold. Pre-polishing surface roughness (Ra1) of all the 90 samples were measured using a Surface Profilometer. The nano-composite disks were then randomly divided into 3 groups with 30 samples in each group. Group I: Control group: The samples were not subjected to any polishing procedures. Group II: Sof-Lex group: Samples subjected to polishing using different grits of Sof-Lex disks. Group III: Diamond polishing paste group: Samples were subjected with a polishing paste consisting of diamond particles. Following polishing procedures, the surface roughness of all samples were measured again to obtain change in surface roughness due to polishing procedures (Ra2), pre immersion spectrophotometric value (ΔE1) was also recorded for baseline color of the samples. The samples were then divided into subgroups (A, B, C, D, E), by including every first sample in Subgroup A, second in Subgroup B, third in Subgroup C, fourth in Subgroup D, and fifth in Subgroup E. Each was immersed in the respective test solution for 10 min, twice a day for 30 days. Group A - Tea, Group B - Coffee, Group C - Cola, Group D - Turmeric, Group E - Control (artificial saliva). Post immersion profilometric value was recorded to evaluate roughness bought about by the solutions (Ra3) and spectrophotometric value was recorded to evaluate the color change in samples (ΔE2). Results were statistically analyzed using ANOVA. Results: Higher mean roughness (Ra2-Ra1) value was recorded in Sof-Lex, followed by Diamond polishing paste and Control group. Comparison of surface roughness caused due to beverages and food colorant solution showed subgroup C (Coca Cola) increased surface roughness in all groups (Group I, II, III). Subgroup D (Turmeric) had the highest discoloration potential (P < 0001) in all groups, followed by coffee, tea, coca-cola and artificial saliva. Sof-Lex polishing System showed most color stability. Conclusion: Polishing procedures significantly roughen the surface of the restoration compared to the unpolished Mylar controls. One-step polishing system (diamond polishing paste) produces a smoother surface compared to a multi-step system (Sof-Lex polishing disks). Turmeric solution caused maximum staining of the samples, to a visually perceptible level. PMID:26229373
Kumari, R Veena; Nagaraj, Hema; Siddaraju, Kishore; Poluri, Ramya Krishna
2015-07-01
It is beyond doubt that finishing and polishing of a composite restoration enhance its esthetics and, is also essential for the health of the periodontium. A variety of instruments are commonly used for finishing and polishing tooth-colored restorative materials Thus, it is important to understand which type of surface finishing treatments would significantly affect the staining and surface irregularities of the composite resin restoration. Still one of the properties of the composite resins that have to pass the test of time is its color stability. In modern day dentistry, a large emphasis is laid over esthetics. Hence, it is important to understand the various agents capable of adversely affecting the esthetics of a restoration due to its staining capacity. Thus, the aim of this in vitro study was to evaluate the effect of surface polishing, oral beverages and food colorants on the color stability and surface roughness of nanocomposite resins. 90 Disks of nanocomposites resin (Filtek Z350 XT) measuring 8 mm in diameter and 2 mm in thickness were fabricated using a custom made silicon mold. Pre-polishing surface roughness (Ra1) of all the 90 samples were measured using a Surface Profilometer. The nano-composite disks were then randomly divided into 3 groups with 30 samples in each group. Group I: The samples were not subjected to any polishing procedures. Group II: Sof-Lex group: Samples subjected to polishing using different grits of Sof-Lex disks. Group III: Diamond polishing paste group: Samples were subjected with a polishing paste consisting of diamond particles. Following polishing procedures, the surface roughness of all samples were measured again to obtain change in surface roughness due to polishing procedures (Ra2), pre immersion spectrophotometric value (ΔE1) was also recorded for baseline color of the samples. The samples were then divided into subgroups (A, B, C, D, E), by including every first sample in Subgroup A, second in Subgroup B, third in Subgroup C, fourth in Subgroup D, and fifth in Subgroup E. Each was immersed in the respective test solution for 10 min, twice a day for 30 days. Group A - Tea, Group B - Coffee, Group C - Cola, Group D - Turmeric, Group E - Control (artificial saliva). Post immersion profilometric value was recorded to evaluate roughness bought about by the solutions (Ra3) and spectrophotometric value was recorded to evaluate the color change in samples (ΔE2). Results were statistically analyzed using ANOVA. Higher mean roughness (Ra2-Ra1) value was recorded in Sof-Lex, followed by Diamond polishing paste and Control group. Comparison of surface roughness caused due to beverages and food colorant solution showed subgroup C (Coca Cola) increased surface roughness in all groups (Group I, II, III). Subgroup D (Turmeric) had the highest discoloration potential (P < 0001) in all groups, followed by coffee, tea, coca-cola and artificial saliva. Sof-Lex polishing System showed most color stability. Polishing procedures significantly roughen the surface of the restoration compared to the unpolished Mylar controls. One-step polishing system (diamond polishing paste) produces a smoother surface compared to a multi-step system (Sof-Lex polishing disks). Turmeric solution caused maximum staining of the samples, to a visually perceptible level.
Electrochemical Polishing Applications and EIS of a Vitamin B{sub 4}-Based Ionic Liquid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wixtrom, Alex I.; Buhler, Jessica E.; Reece, Charles E.
2013-01-01
Modern particle accelerators require minimal interior surface roughness for Niobium superconducting radio frequency (SRF) cavities. Polishing of the Nb is currently achieved via electrochemical polishing with concentrated mixtures of sulfuric and hydrofluoric acids. This acid-based approach is effective at reducing the surface roughness to acceptable levels for SRF use, but due to acid-related hazards and extra costs (including safe disposal of used polishing solutions), an acid-free method would be preferable. This study focuses on an alternative electrochemical polishing method for Nb, using a novel ionic liquid solution containing choline chloride, also known as Vitamin B{sub 4} (VB{sub 4}). Potentiostatic electrochemicalmore » impedance spectroscopy (EIS) was also performed on the VB4-based system. Nb polished using the VB4-based method was found to have a final surface roughness comparable to that achieved via the acid-based method, as assessed by atomic force microscopy (AFM). These findings indicate that acid-free VB{sub 4}-based electrochemical polishing of Nb represents a promising replacement for acid-based methods of SRF cavity preparation.« less
Zanatta, Fabricio Batistin; Pinto, Tatiana Militz; Kantorski, Karla Zanini; Rösing, Cassiano Kuchenbecker
2011-01-01
The aim of this study was to compare the effect of polishing after scaling and root planing on supragingival plaque, calculus formation, and gingival bleeding. The study was designed as a split-mouth randomised clinical trial. Seventy-six patients were submitted to supragingival scaling on the six mandibular anterior teeth with manual curettes until a smooth surface was achieved. Subsequently, quadrants were randomly selected to be polished (test) or not (control) with a rubber cup and pumice. One, two and three weeks following treatment, a blinded examiner evaluated the visible plaque index, gingival bleeding index and the presence of supragingival calculus on the lingual tooth surfaces. The results showed that unpolished surfaces exhibited higher mean percentages of visible plaque in the third week. No statistically significant differences were observed between unpolished and polished sites related to gingival bleeding. Calculus formation was higher on unpolished sites than on polished sites at 2 and 3 weeks. Dental polishing after supragingival scaling contributed to reducing plaque and calculus formation. Polishing exerts an inhibitory effect on plaque and calculus formation.
Laser polishing of additive manufactured Ti alloys
NASA Astrophysics Data System (ADS)
Ma, C. P.; Guan, Y. C.; Zhou, W.
2017-06-01
Laser-based additive manufacturing has attracted much attention as a promising 3D printing method for metallic components in recent years. However, surface roughness of additive manufactured components has been considered as a challenge to achieve high performance. In this work, we demonstrate the capability of fiber laser in polishing rough surface of additive manufactured Ti-based alloys as Ti-6Al-4V and TC11. Both as-received surface and laser-polished surfaces as well as cross-section subsurfaces were analyzed carefully by White-Light Interference, Confocal Microscope, Focus Ion Beam, Scanning Electron Microscopy, Energy Dispersive Spectrometer, and X-ray Diffraction. Results revealed that as-received Ti-based alloys with surface roughness more than 5 μm could be reduce to less than 1 μm through laser polishing process. Moreover, microstructure, microhardness and wear resistance of laser-polished zone was investigated in order to examine the thermal effect of laser polishing processing on the substrate of additive manufactured Ti alloys. This proof-of-concept process has the potential to effectively improve the surface roughness of additive manufactured metallic alloy by local polishing method without damage to the substrate.
Wichniak, Adam; Jankowski, Konrad S; Skalski, Michał; Skwarło-Sońta, Krystyna; Zawilska, Jolanta B; Żarowski, Marcin; Poradowska, Ewa; Jernajczyk, Wojciech
2017-10-29
Circadian rhythm sleep-wake disorders (CRSWD) are a group of disorders, in which the timing of sleep and wakefulness significantly differs from a patient's expectations or socially acceptable times. The aimof the article is to present the current principles for the diagnosis and treatment of CRSWD in adults and children. Guidelines proposed as CRSWD treatment standard are based on the recommendations from the scientific societies involved in the sleep research and medicine. Researchers participating in the guidelines preparation were invited by the Polish Sleep Research Society and the Section of Biological Psychiatry of the Polish Psychiatric Association based on their significant contribution to the circadian rhythm research and/or clinical experience in the treatment of these disorders. Finally, the guidelines were adjusted to the questions and comments given by the members of both Societies. Patients with endogenous CRSWD are often misdiagnosed and treated for insomnia or hypersomnia. Therefore, each patient reporting sleep-wake disorders should be interviewed about the quality of sleep and its timing during free days (e.g. weekends, holidays). Avalid CRSWD diagnosis can be also established by using sleep diaries/logs and actigraphy. The treatment of choice for CRSWD is chronotherapy, which involves melatonin application, light therapy, and behavioral interventions. Sleep disorders associated with shift work and time zone changes are a growing health problem. Interventions for these disorders should primarily focus on prevention. The main problem in the treatment of CRSWD is an invalid diagnosis. Hypnotics and/or psychostimulants are often used instead of chronotherapeutic interventions, what can alleviate symptoms but is not an effective treatment.
Jagiełło, Władysław; Marina, Jagiełło; Maciej, Kalina Roman; Jan, Barczyński Bartłomiej; Artur, Litwiniuk; Jarosław, Klimczak
2017-12-01
Fencing is a combat sport whose form of direct confrontation involves hitting the opponent with a weapon. The purpose of the study was to determine the properties of body composition of female representatives of the Polish national fencing team. The study involved 11 female athletes of the Polish national fencing team. Their age was 16-22 years (19±2.32), body weight 52-78 kg (59.7±7.4), body height 158-183 cm (167.46±6.10) and the training experience 7.64±3.47 years. The reference group consisted of 153 students of Warsaw University of Technology (Poland). Twenty basic somatic characteristics were measured. The following indices were calculated: slenderness, Rohrer's, BMI, Manouvrier's, and pelvic-shoulder indices. Density of the body, total body fat, active tissue, the overall profile of body composition and internal proportions of the body were determined. Analysis of internal proportions of factors of the athletes' body composition revealed significant differences in particular groups of features. The total size of the athletes' bodies is due to less-than-average magnitude of the length and stoutness characteristics and a high magnitude of adiposity (M = 0.63) in the Polish female national team of fencers (sabre) calculated from the normalized values for the control group. The proportions of features within the analysed factors revealed a significant advantage of the length of the upper extremity over the lower one and a distinct advantage of forearm musculature. The specific profile of body composition of female athletes practising sabre fencing is most likely due to long-term effects of training as well as the system of selection of persons with specific somatic prerequisites developed in the course of many years of training practice.
Weight discrepancy and body appreciation among women in Poland and Britain.
Taylor, Donna; Szpakowska, Ilona; Swami, Viren
2013-09-01
Previous studies have suggested that the process of transmigration has detrimental effects on the body image of migrants relative to women in the country of origin. In the present work, we examined the body image of Polish migrants in Britain (n=153), Polish women in Poland (n=153), and a comparison group of British White women (n=110). Participants completed a measure of actual-ideal weight discrepancy and the Body Appreciation Scale (BAS). Contrary to hypotheses, our results showed that Polish women in Poland had significantly higher weight discrepancy than their counterparts in Britain. Further analyses showed that the BAS reduced to two dimensions among Polish participants, with Polish participants in Poland having significantly lower body appreciation than Polish migrants. We suggest that the sociocultural changes that have taken place in Eastern Europe may place women in that region at relatively high risk for developing negative body image. Copyright © 2013 Elsevier Ltd. All rights reserved.
Influence of the processing route of porcelain/Ti-6Al-4V interfaces on shear bond strength.
Toptan, Fatih; Alves, Alexandra C; Henriques, Bruno; Souza, Júlio C M; Coelho, Rui; Silva, Filipe S; Rocha, Luís A; Ariza, Edith
2013-04-01
This study aims at evaluating the two-fold effect of initial surface conditions and dental porcelain-to-Ti-6Al-4V alloy joining processing route on the shear bond strength. Porcelain-to-Ti-6Al-4V samples were processed by conventional furnace firing (porcelain-fused-to-metal) and hot pressing. Prior to the processing, Ti-6Al-4V cylinders were prepared by three different surface treatments: polishing, alumina or silica blasting. Within the firing process, polished and alumina blasted samples were subjected to two different cooling rates: air cooling and a slower cooling rate (65°C/min). Metal/porcelain bond strength was evaluated by shear bond test. The data were analyzed using one-way ANOVA followed by Tuckey's test (p<0.05). Before and after shear bond tests, metallic surfaces and metal/ceramic interfaces were examined by Field Emission Gun Scanning Electron Microscope (FEG-SEM) equipped with Energy Dispersive X-Ray Spectroscopy (EDS). Shear bond strength values of the porcelain-to-Ti-6Al-4V alloy interfaces ranged from 27.1±8.9MPa for porcelain fused to polished samples up to 134.0±43.4MPa for porcelain fused to alumina blasted samples. According to the statistical analysis, no significant difference were found on the shear bond strength values for different cooling rates. Processing method was statistically significant only for the polished samples, and airborne particle abrasion was statistically significant only for the fired samples. The type of the blasting material did not cause a statistically significant difference on the shear bond strength values. Shear bond strength of dental porcelain to Ti-6Al-4V alloys can be significantly improved from controlled conditions of surface treatments and processing methods. Copyright © 2013 Elsevier Ltd. All rights reserved.
Effects of different preparation procedures during tooth whitening on enamel bonding.
Wilson, Dustin; Xu, Changqi; Hong, Liang; Wang, Yong
2009-04-01
The objective of this study was to assess effects of some clinically related preparation procedures during tooth whitening on enamel bonding properties. Sixty-two extracted human teeth were cleaned and divided into four groups. Forty-two of the teeth were left with their natural surface intact while 20 teeth were polished to form a flat surface. Half of the tooth served as the experimental side and received one of the two whitening products: Opalescence (10% carbamide peroxide) and Crest Whitestrips (6.5% hydrogen peroxide), for 2 weeks. Post-bleaching intervals included: 1 day, 1 week, and 2 weeks. On these days, tooth (10 mm x 1.5 mm x 1.5 mm) sections were evaluated using Raman spectroscopy, scanning electron microscopy and tensile bond strength tests. T-test, ANOVA test, and mixed model regression analysis were used to assess the differences. No significant difference existed between natural surface and polished surface teeth for all groups at both Day One and Week Two (P > 0.05). On Day One, both treated groups had significant lower bond strength than the control group (P = 0.002). After 2 weeks, no significant difference existed between any group (P = 0.381). SEM indicated that resin-enamel interfaces in bleached enamel exhibited more defects in granular formations when compared to the control. Raman results indicated a lower degree of polymerization (DP) of adhesive at the interface for treated teeth surfaces. In summary, pre-bleaching surface treatments such as polish or non-polish, had no effect on bond strength. Bleaching significantly decreased bond strength initially, but after 2 weeks, bleaching had no significant effect on bond strength. Storage time had significant effect on Opalescence treated enamel, but not on control and Whitestrip treated enamel. The decrease of bond strength may be related to interfacial defects and low DP due to oxygen release after bleaching.
Color stability of nanocomposites polished with one-step systems.
Ergücü, Zeynep; Türkün, L Sebnem; Aladag, Akin
2008-01-01
This study compared the color changes of five novel resin composites polished with two one-step polishing systems when exposed to coffee solution. The resin composites tested were Filtek Supreme XT, Grandio, CeramX, Premise and Tetric EvoCeram. A total of 150 discs (30/resin composites, 10 x 2 mm) were fabricated. Ten specimens/resin composites cured under Mylar strips served as the control. The other samples were polished with PoGo and OptraPol discs for 30 seconds using a slow speed handpiece and immersed in coffee (Nescafé) for seven days. Color measurements were made with Vita Easyshade at baseline and after one and seven days. Repeated Measures ANOVA and Bonferroni tests were used for statistical analyses (p< or =0.05). The differences between the mean DeltaE* values for the resin composites polished with two different one-step systems were statistically significant (p<0.05). After one week, all materials exhibited significant color changes compared to baseline. All Mylar finished specimens showed the most intense staining (p<0.05). There were no significant differences between the OptraPol and PoGo polished groups. Mylar-finished specimens of CeramX, Tetric EvoCeram, Premise and Filtek Supreme XT presented the greatest staining (p<0.05). For Grandio, there were no significant differences between the Mylar and PoGo groups, while the most stain resistant surfaces were attained with OptraPol. Removing the outermost resin layer by polishing procedures is essential to achieving a stain resistant, more esthetically stable surface. One-step polishing systems can be used successfully for polishing nanocomposites.
The Battle of Warsaw, 1920: Impact on Operational Thought
1994-05-06
battles and campaigns is invaluable to the professional soldier. In his article , "Of Aphorisms, Lessons, and Paradigms," Gary Cox cautions that...started and then broke off without any apparent plan or pattern. 1 8 9 In his article "Beyond the Bug: Historiography of the Soviet-Polish War," James...brigades under Austrian operational control. The first two brigades had an initial strength of about 2,500 men. The first brigade was personally
ERIC Educational Resources Information Center
Hart, Doug; Cumming, Alister
The report details results of a survey of students who had completed Level 3 of the Ontario (Canada) Language Instruction fore Newcomers to Canada (LINC) program. The initial followup study included 103 native speakers of Arabic, 208 speakers of Cantonese, 198 of Polish, 40 of Somali, 155 of Spanish, and 196 of Tamil. Ten from each group except…
Jones, Gabrielle; Pihier, Nathalie; Vanbockstael, Caroline; Le Hello, Simon; Cadel Six, Sabrina; Fournet, Nelly; Jourdan-da Silva, Nathalie
2016-10-06
A prolonged outbreak of Salmonella enterica serotype Enteritidis occurred in northern France between December 2014 and April 2015. Epidemiological investigations following the initial notification on 30 December 2014 of five cases of salmonellosis (two confirmed S. Enteritidis) in young children residing in the Somme department revealed that all cases frequented the same food bank A. Further epidemiological, microbiological and food trace-back investigations indicated frozen beefburgers as the source of the outbreak and the suspected lot originating from Poland was recalled on 22 January 2015. On 2 March 2015 a second notification of S. Enteritidis cases in the Somme reinitiated investigations that confirmed a link with food bank A and with consumption of frozen beefburgers from the same Polish producer. In the face of a possible persistent source of contamination, all frozen beefburgers distributed by food bank A and from the same origin were blocked on 3 March 2015. Microbiological analyses confirmed contamination by S. Enteritidis of frozen beefburgers from a second lot remaining in cases' homes. A second recall was initiated on 6 March 2015 and all frozen beefburgers from the Polish producer remain blocked after analyses identified additional contaminated lots over several months of production. This article is copyright of The Authors, 2016.
Friction coefficient and effective interference at the implant-bone interface.
Damm, Niklas B; Morlock, Michael M; Bishop, Nicholas E
2015-09-18
Although the contact pressure increases during implantation of a wedge-shaped implant, friction coefficients tend to be measured under constant contact pressure, as endorsed in standard procedures. Abrasion and plastic deformation of the bone during implantation are rarely reported, although they define the effective interference, by reducing the nominal interference between implant and bone cavity. In this study radial forces were analysed during simulated implantation and explantation of angled porous and polished implant surfaces against trabecular bone specimens, to determine the corresponding friction coefficients. Permanent deformation was also analysed to determine the effective interference after implantation. For the most porous surface tested, the friction coefficient initially increased with increasing normal contact stress during implantation and then decreased at higher contact stresses. For a less porous surface, the friction coefficient increased continually with normal contact stress during implantation but did not reach the peak magnitude measured for the rougher surface. Friction coefficients for the polished surface were independent of normal contact stress and much lower than for the porous surfaces. Friction coefficients were slightly lower for pull-out than for push-in for the porous surfaces but not for the polished surface. The effective interference was as little as 30% of the nominal interference for the porous surfaces. The determined variation in friction coefficient with radial contact force, as well as the loss of interference during implantation will enable a more accurate representation of implant press-fitting for simulations. Copyright © 2015 Elsevier Ltd. All rights reserved.
Production of primary mirror segments for the Giant Magellan Telescope
NASA Astrophysics Data System (ADS)
Martin, H. M.; Allen, R. G.; Burge, J. H.; Davis, J. M.; Davison, W. B.; Johns, M.; Kim, D. W.; Kingsley, J. S.; Law, K.; Lutz, R. D.; Strittmatter, P. A.; Su, P.; Tuell, M. T.; West, S. C.; Zhou, P.
2014-07-01
Segment production for the Giant Magellan Telescope is well underway, with the off-axis Segment 1 completed, off-axis Segments 2 and 3 already cast, and mold construction in progress for the casting of Segment 4, the center segment. All equipment and techniques required for segment fabrication and testing have been demonstrated in the manufacture of Segment 1. The equipment includes a 28 m test tower that incorporates four independent measurements of the segment's figure and geometry. The interferometric test uses a large asymmetric null corrector with three elements including a 3.75 m spherical mirror and a computer-generated hologram. For independent verification of the large-scale segment shape, we use a scanning pentaprism test that exploits the natural geometry of the telescope to focus collimated light to a point. The Software Configurable Optical Test System, loosely based on the Hartmann test, measures slope errors to submicroradian accuracy at high resolution over the full aperture. An enhanced laser tracker system guides the figuring through grinding and initial polishing. All measurements agree within the expected uncertainties, including three independent measurements of radius of curvature that agree within 0.3 mm. Segment 1 was polished using a 1.2 m stressed lap for smoothing and large-scale figuring, and a set of smaller passive rigid-conformal laps on an orbital polisher for deterministic small-scale figuring. For the remaining segments, the Mirror Lab is building a smaller, orbital stressed lap to combine the smoothing capability with deterministic figuring.
Approach for axisymmetrical asphere polishing with full-area tools
NASA Astrophysics Data System (ADS)
Novi, Andrea; Melozzi, Mauro
1999-09-01
Aspherics up to 500 nm diameter in optical glass or in ceramic substrates have been fabricated using area- compensated polishing tools and conventional optical shop machines. The tool forms are derived starting from the actual shape of the part under figuring. The figure error is measured using an interferometer mounted on-line with the polishing machine. Measurements are taken after each polishing step to compute the new tool form. The process speeds up the fabrication of aspheres and it improves repeatability in the manufacturing of axisymmetrical optics using moderate cost equipment's up to astronomical requirements. In the paper we present some examples of polishing results using the above mentioned approach on different aspherics for space applications.
[Effectiveness of resuscitation delivered by Polish paramedics].
Guła, Przemysław; Koszowska, Małgorzata; Larysz, Dawid; Koszowski, Marcin; Nabzdyk, Andrzej; Maślanka, Marek
2008-01-01
The aim of the study was to evaluate the effectiveness and skills in BLS and use of automatic external defibrillators (AED) by paramedics from units of the National Fire and Rescue System. One hundred and fifty-eight rescuers participated in the study. They included both volunteers and professionals, and were recruited from 40 different rescue organizations. The results were evaluated by experienced physicians, nurses and paramedics, all holders of ALS and BLS-AED instructor diplomas. The following skills were evaluated: initial assessment, ventilation, chest compression, and use of the AED. The quality of the BLS-AED was rated against the professional experience of the rescuers, and the frequency of repetition training. Although theoretical background was rated good, 45% of participants omitted assessment of consciousness. Airway patency and respiration were properly assessed by 82.5% and 72.5% of paramedics respectively, but only 20% could provide adequate rescue breaths to the phantom victims. Circulation was correctly assessed by 65% of participants, but once again, only 34.4% of paramedics could provide adequate chest compression. The results correlated positively with professional experience, based on the number of rescue missions (0-250, mean 4.3, median 1). The results proved that despite adequate theoretical knowledge, practical skills of paramedics were poor, due to the inadequate time devoted to practical training and the lack of certificate courses.
Rao, Duggineni Chalapathi; Kalavathy, N; Mohammad, H S; Hariprasad, A; Kumar, C Ravi
2015-01-01
Surface roughness promotes adhesion and colonization of denture plaque. Therefore, it is important to know the effects of polishing and finishing on the surface roughness of various acrylic resin materials. To evaluate and compare the effects of different conventional lathe polishing techniques on heat cured acrylic resins in producing surface roughness. Three different commercially available heat-cured acrylic resin materials namely DPI, Meliodent and Trevalon Hi were selected. 30 Specimens of each acrylic material (30 x 3 = 90, 10 x 60 x 2mm) were prepared and divided into 5 groups, each group consisted of 6 Nos. of specimens per material(6x3=18) and were grouped as Group A(unfinished), Group B (finished), Group C (Polishing Paste), Group D (Polishing Cake) and Group E (Pumice and Gold rouge). The resulted surface roughness (μm) was measured using Perthometer and observed under Scanning Electron Microscope. The values obtained were subjected statistical analyses. Among the materials tested, better results were obtained with Trevalon Hi followed by Meliodent and DPI. Among the polishing methods used, superior results were obtained with universal polishing paste followed by polishing cake; Pumice and Gold rouge. Although Pumice and Gold rouge values produced greater roughness value, they were well within the threshold value of 0.2 mm.
Effects of chemo-mechanical polishing on CdZnTe X-ray and gamma-ray detectors
Egarievwe, Stephen E.; Hossain, Anwar; Okwechime, Ifechukwude O.; ...
2015-06-23
Here, mechanically polishing cadmium zinc telluride (CdZnTe) wafers for x-ray and gamma-ray detectors often is inadequate in removing surface defects caused by cutting them from the ingots. Fabrication-induced defects, such as surface roughness, dangling bonds, and nonstoichiometric surfaces, often are reduced through polishing and etching the surface. In our earlier studies of mechanical polishing with alumina powder, etching with hydrogen bromide in hydrogen peroxide solution, and chemomechanical polishing with bromine–methanol–ethylene glycol solution, we found that the chemomechanical polishing process produced the least surface leakage current. In this research, we focused on using two chemicals to chemomechanically polish CdZnTe wafers aftermore » mechanical polishing, viz. bromine–methanol–ethylene glycol (BME) solution, and hydrogen bromide (HBr) in a hydrogen peroxide and ethylene–glycol solution. We used x-ray photoelectron spectroscopy (XPS), current–voltage (I–V) measurements, and Am-241 spectral response measurements to characterize and compare the effects of each solution. The results show that the HBr-based solution produced lower leakage current than the BME solution. Results from using the same chemomechanical polishing solution on two samples confirmed that the surface treatment affects the measured bulk current (a combination of bulk and surface currents). XPS results indicate that the tellurium oxide to tellurium peak ratios for the mechanical polishing process were reduced significantly by chemomechanical polishing using the BME solution (78.9% for Te 3d 5/2O 2 and 76.7% for Te 3d 3/2O 2) compared with the HBr-based solution (27.6% for Te 3d 5/2O 2 and 35.8% for Te 3d 3/2O 2). Spectral response measurements showed that the 59.5-keV peak of Am-241 remained under the same channel number for all three CdZnTe samples. While the BME-based solution gave a better performance of 7.15% full-width at half-maximum (FWHM) compared with 7.59% FWHM for the HBr-based solution, the latter showed a smaller variation in performance of 0.39% FWHM over 7 days compared with 0.69% for the BME-based solution.« less
New method for revealing dislocations in garnet: premelting decoration
NASA Astrophysics Data System (ADS)
Liu, Xiangwen; Xie, Zhanjun; Jin, Zhenmin; Li, Zhuoyue; Ao, Ping; Wu, Yikun
2018-05-01
Premelting decoration (PMD) of dislocation experiments was carried out on garnets at 1 atmosphere pressure and temperatures of 800-1000 °C. Numerous decorated lines were observed on the polished surface of heat-treated garnet grains. The results of scanning electron microscopy, laser Raman spectroscopy and transmission electron microscopy (TEM) analyses indicate that these decorated lines were generated by premelting reaction along the dislocation lines and subgrain boundaries. The constituents of decorated lines on the polished surface of garnet are hematite, magnetite, and melt. While, in the interior of garnet, their constituents changed to Al-bearing magnetite and melt. The dislocation density of a gem-quality megacrystal garnet grain by means of the PMD is similar to that obtained by TEM, which confirms that the PMD is a new reliable method for revealing dislocations in garnet. This method greatly reduces the cost and time involved in the observation of dislocation microstructures in deformed garnet.
Analyzing and improving surface texture by dual-rotation magnetorheological finishing
NASA Astrophysics Data System (ADS)
Wang, Yuyue; Zhang, Yun; Feng, Zhijing
2016-01-01
The main advantages of magnetorheological finishing (MRF) are its high convergence rate of surface error, the ability of polishing aspheric surfaces and nearly no subsurface damage. However, common MRF produces directional surface texture due to the constant flow direction of the magnetorheological (MR) polishing fluid. This paper studies the mechanism of surface texture formation by texture modeling. Dual-rotation magnetorheological finishing (DRMRF) is presented to suppress directional surface texture after analyzing the results of the texture model for common MRF. The results of the surface texture model for DRMRF and the proposed quantitative method based on mathematical statistics indicate the effective suppression of directional surface texture. An experimental setup is developed and experiments show directional surface texture and no directional surface texture in common MRF and DRMRF, respectively. As a result, the surface roughness of DRMRF is 0.578 nm (root-mean-square value) which is lower than 1.109 nm in common MRF.
Bacterial cells enhance laser driven ion acceleration
Dalui, Malay; Kundu, M.; Trivikram, T. Madhu; Rajeev, R.; Ray, Krishanu; Krishnamurthy, M.
2014-01-01
Intense laser produced plasmas generate hot electrons which in turn leads to ion acceleration. Ability to generate faster ions or hotter electrons using the same laser parameters is one of the main outstanding paradigms in the intense laser-plasma physics. Here, we present a simple, albeit, unconventional target that succeeds in generating 700 keV carbon ions where conventional targets for the same laser parameters generate at most 40 keV. A few layers of micron sized bacteria coating on a polished surface increases the laser energy coupling and generates a hotter plasma which is more effective for the ion acceleration compared to the conventional polished targets. Particle-in-cell simulations show that micro-particle coated target are much more effective in ion acceleration as seen in the experiment. We envisage that the accelerated, high-energy carbon ions can be used as a source for multiple applications. PMID:25102948
Femtosecond laser fabricating black silicon in alkaline solution
NASA Astrophysics Data System (ADS)
Meng, Jiao; Song, Haiying; Li, Xiaoli; Liu, Shibing
2015-03-01
An efficient approach for enhancing the surface antireflection is proposed, in which a black silicon is fabricated by a femtosecond laser in alkaline solution. In the experiment, 2 wt% NaOH solution is formulated at room temperature (22 ± 1 °C). Then, a polished silicon is scanned via femtosecond laser irradiation in 2 wt% NaOH solution. Jungle-like microstructures on the black silicon surface are characterized using an atomic force microscopy. The reflectance of the black silicon is measured at the wavelengths ranging from 400 to 750 nm. Compared to the polished silicon, the black silicon can significantly suppress the optical reflection throughout the visible region (<5 %). Meanwhile, we also investigated the factors of the black silicon, including the femtosecond laser pulse energy and the scanning speed. This method is simple and effective to acquire the black silicon, which probably has a large advantage in fast and cost-effective black silicon fabrication.
Translating Key Competences into the School Curriculum: Lessons from the Polish Experience
ERIC Educational Resources Information Center
Dabrowski, Miroslaw; Wisniewski, Jerzy
2011-01-01
Over the last 20 years, Poland has gone through a major transition process in which the challenges for education in terms of new approaches to learning and teaching have been compounded by broader changes such as the democratisation of structures and processes and the major economic and social changes. This article is a case study that examines…
The Pascal-Fermat Correspondence: How Mathematics Is Really Done
ERIC Educational Resources Information Center
Devlin, Keith
2010-01-01
The mathematics that students see in their textbooks is highly polished. The steps required to solve a problem are all clearly laid out. Thus, students are denied what could be a valuable learning experience. Often when students meet a problem that differs only slightly from the ones in the book, they are unable to proceed and afraid to "play…
ERIC Educational Resources Information Center
Tomczak, Ewa; Ewert, Anna
2015-01-01
We examine cross-linguistic influence in the processing of motion sentences by L2 users from an embodied cognition perspective. The experiment employs a priming paradigm to test two hypotheses based on previous action and motion research in cognitive psychology. The first hypothesis maintains that conceptual representations of motion are embodied…
[Transsexualism as an interdisciplinary phenomenon].
Bilikiewicz, Adam; Gromska, Jadwiga
2005-01-01
The authors express their criticism on the currently prevailing Polish diagnostic and therapeutic criteria of transsexualism. Relying on their clinical experience and expertise (opinions for the court) as well as current literature, they point to the necessity of a discussion between specialists from various medical fields (psychiatry, sexology, urology, surgery, endocrinology, genetics) and humanistic sciences (psychology, sociology, law, ethics) on this interdisciplinary phenomenon.
ERIC Educational Resources Information Center
Kujalowicz, Agnieszka; Zajdler, Ewa
2009-01-01
Many offline studies on third language acquisition suggest strong connections between speakers' L3 and L2 rather than between their L3 and L1, especially if the foreign languages are typologically related (Cenoz, Hufeisen, & Jessner, 2001; Singleton, 2001). However, a recent online study investigating trilingual processing did not provide evidence…
Identifying Sources of Volatile Organic Compounds and Aldehydes in a High Performance Building
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ortiz, Anna C.; Russell, Marion; Lee, Wen-Yee
The developers of the Paharpur Business Center (PBC) and Software Technology Incubator Park in New Delhi, India offer an environmentally sustainable building with a strong emphasis on energy conservation, waste minimization and superior indoor air quality (IAQ). To achieve the IAQ goal, the building utilizes a series of air cleaning technologies for treating the air entering the building. These technologies include an initial water wash followed by ultraviolet light treatment and biolfiltration using a greenhouse located on the roof and numerous plants distributed throughout the building. Even with the extensive treatment of makeup air and room air in the PBC,more » a recent study found that the concentrations of common volatile organic compounds and aldehydes appear to rise incrementally as the air passes through the building from the supply to the exhaust. This finding highlights the need to consider the minimization of chemical sources in buildings in combination with the use of advanced air cleaning technologies when seeking to achieve superior IAQ. The goal of this project was to identify potential source materials for indoor chemicals in the PBC. Samples of building materials, including wood paneling (polished and unpolished), drywall, and plastic from a hydroponic drum that was part of the air cleaning system, were collected from the building for testing. All materials were collected from the PBC building and shipped to the Lawrence Berkeley National Laboratory (LBNL) for testing. The materials were pre-conditioned for two different time periods before measuring material and chemical specific emission factors for a range of VOCs and Aldehydes. Of the six materials tested, we found that the highest emitter of formaldehyde was new plywood paneling. Although polish and paint contribute to some VOC emissions, the main influence of the polish was in altering the capacity of the surface to accumulate formaldehyde. Neither the new nor aged polish contributed significantly to formaldehyde emissions. The VOC emission stream (excluding formaldehyde) was composed of up to 18 different chemicals and the total VOC emissions ranged in magnitude from 7 mu g/m2/h (old wood with old polish) to>500 mu g/m2/h (painted drywall). The formaldehyde emissions from drywall and old wood with either new or old polish were ~;;15 mu g/m2/h while the new wood material emitted>100 mu g/m2/h. However, when the projected surface area of each material in the building was considered, the new wood, old wood and painted drywall material all contributed substantially to the indoor formaldehyde loading while the coatings contributed primarily to the VOCs.« less
Polishers around the globe: an overview on the market of large astronomical mirrors
NASA Astrophysics Data System (ADS)
Döhring, Thorsten
2014-07-01
Astronomical mirrors are key elements in modern optical telescopes, their dimensions are usually large and their specifications are demanding. Only a limited number of skilled companies respectively institutions around the world are able to master the challenge to polish an individual astronomical mirror, especially in dimensions above one meter. This paper presents an overview on the corresponding market including a listing of polishers around the globe. Therefore valuable information is provided to the astronomical community: Polishers may use the information as a global competitor database, astronomers and project managers may get more transparency on potential suppliers, and suppliers of polishing equipment may learn about unknown potential customers in other parts of the world. An evaluation of the historical market demand on large monolithic astronomical mirrors is presented. It concluded that this is still a niche market with a typical mean rate of 1-2 mirrors per year. Polishing of such mirrors is an enabling technology with impact on the development of technical know-how, public relation, visibility and reputation of the supplier. Within a corresponding technical discussion different polishing technologies are described. In addition it is demonstrated that strategic aspects and political considerations are influencing the selection of the optical finisher.
Jiang, Hong; Lv, Da; Liu, Kailei; Zhang, Weisheng; Yao, Yao; Liao, Chuhong
2014-05-01
To compare the surface roughness of nanofilled dental composite resin and microhybrid composite resins after curing and polishing. A nanofilled composite (Z350) and 4 microhybrid composites (P60, Z250, Spectrum, and AP-X) were fabricated from the lateral to the medial layers to prepare 8 mm×8 mm×5 mm cubical specimens. The 4 lateral surfaces of each specimens were polished with abrasive disks (Super-Snap). Profilometer was used to test the mean surface roughness (Ra) after polishing. P60 had the lowest Ra (0.125∓0.030 µm) followed by Z250 and Spectrum. The Ra of Z350 (0.205∓0.052 µm) was greater than that of the other 3 resins, and AP-X had the roughest surfaces. Under scanning electron microscope, the polished faces of P60 resin were characterized by minor, evenly distributed particles with fewer scratches; the polished faces of Z350 presented with scratches where defects of the filling material could be seen. The nanofilled composite Z350 has smooth surface after polishing by abrasive disks, but its smoothness remains inferior to that of other micro-hybrid composite resins.
NASA Astrophysics Data System (ADS)
Miura, Sadahiko; Honjo, Hiroaki; Kinoshita, Keizo; Tokutome, Keiichi; Koike, Hiroaki; Ikeda, Shoji; Endoh, Tetsuo; Ohno, Hideo
2015-04-01
Perpendicular-anisotropy magnetic tunnel junctions (MTJs) were prepared on four substrate geometries, i.e., directly on the axis of the bottom electrode contact, directly off the axis of the bottom electrode contact, on the axis of the bottom electrode contact with a polished bottom electrode, and off the axis of the bottom electrode contact with a polished bottom electrode. Electrical shorts were observed for direct on-axis geometry at a certain extent, whereas there were no electrical shorts for the other three geometries. The MR ratio/σR, JC0, and thermal stability factor of the devices for polish on-axis geometry were almost the same as those for polish off-axis geometry. From TEM observations of the polish on-axis device, the interface between the bottom contact and the base electrode was determined to be rough, whereas the MgO barrier layer was determined to be smooth, indicating that the polish process was effective for smooth magnetic tunnel junction fabrication over the bottom contact. MTJs for polish on-axis geometry eliminated the base electrode resistance and increased the magnetoresistance ratio. This technology contributes to the higher density of spin transfer torque magnetic random access memory.
Mechanized Polishing of Optical Rod and Fiber Ends
NASA Technical Reports Server (NTRS)
Gum, J. S.
1987-01-01
Workpiece holder for standard grinding and polishing machine makes it easier to produce optical finish and shape on end of metal or glass rod or bundle of optical fibers. Previously, glass parts lapped and polished manually, time-consuming procedure calling for considerable skill.
POLISHING EFFLUENT FROM A PERCHLORATE-REDUCING ANAEROBIC BIOLOGICAL CONTACTOR
The U.S. Environmental Protection Agency undertook at 3 ½ year pilot-scale biological perchlorate treatment study that included two long (311 and 340 days) examinations of anaerobic effluent polishing. The polishing system consisted of hydrogen peroxide addition and aeration, fo...
Rediscovery of Polish meteorites
NASA Astrophysics Data System (ADS)
Tymiński, Z.; Stolarz, M.; Żołądek, P.; Wiśniewski, M.; Olech, A.
2016-01-01
The total number of Polish registered meteorites (by July 2016) including the meteoritical artifacts as Czestochowa Raków I and II is 22. Most of them are described by the pioneer of Polish Meteoritics Jerzy Pokrzywnicki who also identified the meteorite fall locations. In recent years prospectors found impressive specimens of known Polish meteorites such as Morasko: 34 kg, 50 kg, 164 kg, 174 kg and 261 kg or Pultusk: 1578 g, 1576 g, 1510 g, 610 g and 580 g expanding and determining precisely the known meteorite strewn fields.
Yap, Adrian U J; Yap, W Y; Yeo, Egwin J C; Tan, Jane W S; Ong, Debbie S B
2003-01-01
This study investigated the effect of finishing/polishing techniques on the microleakage of resin-modified glass ionomer restorations. Class V preparations were made on the buccal and lingual/palatal surfaces of freshly extracted teeth. The cavities on each tooth were restored with Fuji II LC (FT [GC]) and Photac-Fil Quick (PF [3M-ESPE]) according to manufacturers' instructions. Immediately after light-polymerization, gross finishing was done with eight-fluted tungsten carbide burs. The teeth were then randomly divided into four groups and finishing/polishing was done with one of the following systems: (a) Robot Carbides (RC); (b) Super-Snap system (SS); (c) OneGloss (OG) and (d) CompoSite Polishers (CS). The sample size for each material-finishing/polishing system combination was eight. After finishing/polishing, the teeth were stored in distilled water at 37 degrees C for one week. The root apices were then sealed with acrylic and two coats of varnish was applied 1 mm beyond the restoration margins. The teeth were subsequently subjected to dye penetration testing (0.5% basic fuchsin), sectioned and scored. Data was analyzed using Kruskal-Wallis and Mann-Whitney U tests at a significance level of 0.05. Results of statistical analysis were as follows: Enamel margins: PF-OG
NASA Astrophysics Data System (ADS)
Jacobs, Stephen D.
2011-10-01
Deterministic final polishing of high precision optics using sub-aperture processing with magnetorheological finishing (MRF) is an accepted practice throughout the world. A wide variety of materials can be successfully worked with aqueous (pH 10), magnetorheological (MR) fluids, using magnetic carbonyl iron (CI) and either ceria or nanodiamond nonmagnetic abrasives. Polycrystalline materials like zinc sulfide (ZnS) and zinc selenide (ZnSe) are difficult to polish at pH 10 with MRF, due to their grain size and the relatively low stiffness of the MR fluid lap. If microns of material are removed, the grain structure of the material begins to appear. In 2005, Kozhinova et al. (Appl. Opt. 44 4671-4677) demonstrated that lowering pH could improve MRF of ZnS. However, magnetic CI particle corrosion rendered their low pH approach unstable and unsuitable for commercial implementation. In 2009, Shafrir et al. described a sol-gel coating process for manufacturing a zirconia-coated CI particle that protects the magnetic core from aqueous corrosion (Appl. Opt .48 6797-6810). The coating process produces free nanozirconia polishing abrasives during the coating procedure, thereby creating an MR polishing powder that is "self-charged" with the polishing abrasive. By simply adding water, it was possible to polish optical glasses and ceramics with good stability at pH 8 for three weeks. The development of a corrosion resistant, MR polishing powder, opens up the possibility for polishing additional materials, wherein the pH may be adjusted to optimize effectiveness. In this paper we describe the CI coating process, the characterization of the coated powder, and procedures for making stable MR fluids with adjustable pH, giving polishing results for a variety of optical glasses and crystalline ceramics.
Hmaidouch, Rim; Müller, Wolf-Dieter; Lauer, Hans-Christoph; Weigl, Paul
2014-12-01
The aim of this study was to evaluate the effect of controlled intraoral grinding and polishing on the roughness of full-contour zirconia compared to classical veneered zirconia. Thirty bar-shaped zirconia specimens were fabricated and divided into two groups (n=15). Fifteen specimens (group 1) were glazed and 15 specimens (group 2) were veneered with feldspathic ceramic and then glazed. Prior to grinding, maximum roughness depth (Rmax) values were measured using a profilometer, 5 times per specimen. Simulated clinical grinding and polishing were performed on the specimens under water coolant for 15 s and 2 N pressure. For grinding, NTI diamonds burs with grain sizes of 20 µm, 10 µm, and 7.5 µm were used sequentially. The ground surfaces were polished using NTI kits with coarse, medium and fine polishers. After each step, Rmax values were determined. Differences between groups were examined using one-way analysis of variance (ANOVA). The roughness of group 1 was significantly lower than that of group 2. The roughness increased significantly after coarse grinding in both groups. The results after glazing were similar to those obtained after fine grinding for non-veneered zirconia. However, fine-ground veneered zirconia had significantly higher roughness than venerred, glazed zirconia. No significant difference was found between fine-polished and glazed zirconia, but after the fine polishing of veneered zirconia, the roughness was significantly higher than after glazing. It can be concluded that for full-contour zirconia, fewer defects and lower roughness values resulted after grinding and polishing compared to veneered zirconia. After polishing zirconia, lower roughness values were achieved compared to glazing; more interesting was that the grinding of glazed zirconia using the NTI three-step system could deliver smooth surfaces comparable to untreated glazed zirconia surfaces.
Hmaidouch, Rim; Müller, Wolf-Dieter; Lauer, Hans-Christoph; Weigl, Paul
2014-01-01
The aim of this study was to evaluate the effect of controlled intraoral grinding and polishing on the roughness of full-contour zirconia compared to classical veneered zirconia. Thirty bar-shaped zirconia specimens were fabricated and divided into two groups (n=15). Fifteen specimens (group 1) were glazed and 15 specimens (group 2) were veneered with feldspathic ceramic and then glazed. Prior to grinding, maximum roughness depth (Rmax) values were measured using a profilometer, 5 times per specimen. Simulated clinical grinding and polishing were performed on the specimens under water coolant for 15 s and 2 N pressure. For grinding, NTI diamonds burs with grain sizes of 20 µm, 10 µm, and 7.5 µm were used sequentially. The ground surfaces were polished using NTI kits with coarse, medium and fine polishers. After each step, Rmax values were determined. Differences between groups were examined using one-way analysis of variance (ANOVA). The roughness of group 1 was significantly lower than that of group 2. The roughness increased significantly after coarse grinding in both groups. The results after glazing were similar to those obtained after fine grinding for non-veneered zirconia. However, fine-ground veneered zirconia had significantly higher roughness than venerred, glazed zirconia. No significant difference was found between fine-polished and glazed zirconia, but after the fine polishing of veneered zirconia, the roughness was significantly higher than after glazing. It can be concluded that for full-contour zirconia, fewer defects and lower roughness values resulted after grinding and polishing compared to veneered zirconia. After polishing zirconia, lower roughness values were achieved compared to glazing; more interesting was that the grinding of glazed zirconia using the NTI three-step system could deliver smooth surfaces comparable to untreated glazed zirconia surfaces. PMID:25059249
NASA Astrophysics Data System (ADS)
Li, Junye; Hu, Jinglei; Wang, Binyu; Sheng, Liang; Zhang, Xinming
2018-03-01
In order to investigate the effect of abrasive flow polishing surface variable diameter pipe parts, with high precision dispensing needles as the research object, the numerical simulation of the process of polishing high precision dispensing needle was carried out. Analysis of different volume fraction conditions, the distribution of the dynamic pressure and the turbulence viscosity of the abrasive flow field in the high precision dispensing needle, through comparative analysis, the effectiveness of the abrasive grain polishing high precision dispensing needle was studied, controlling the volume fraction of silicon carbide can change the viscosity characteristics of the abrasive flow during the polishing process, so that the polishing quality of the abrasive grains can be controlled.
High quality optically polished aluminum mirror and process for producing
NASA Technical Reports Server (NTRS)
Lyons, III, James J. (Inventor); Zaniewski, John J. (Inventor)
2005-01-01
A new technical advancement in the field of precision aluminum optics permits high quality optical polishing of aluminum monolith, which, in the field of optics, offers numerous benefits because of its machinability, lightweight, and low cost. This invention combines diamond turning and conventional polishing along with india ink, a newly adopted material, for the polishing to accomplish a significant improvement in surface precision of aluminum monolith for optical purposes. This invention guarantees the precise optical polishing of typical bare aluminum monolith to surface roughness of less than about 30 angstroms rms and preferably about 5 angstroms rms while maintaining a surface figure accuracy in terms of surface figure error of not more than one-fifteenth of wave peak-to-valley.
High quality optically polished aluminum mirror and process for producing
NASA Technical Reports Server (NTRS)
Lyons, III, James J. (Inventor); Zaniewski, John J. (Inventor)
2002-01-01
A new technical advancement in the field of precision aluminum optics permits high quality optical polishing of aluminum monolith, which, in the field of optics, offers numerous benefits because of its machinability, lightweight, and low cost. This invention combines diamond turning and conventional polishing along with india ink, a newly adopted material, for the polishing to accomplish a significant improvement in surface precision of aluminum monolith for optical purposes. This invention guarantees the precise optical polishing of typical bare aluminum monolith to surface roughness of less than about 30 angstroms rms and preferably about 5 angstroms rms while maintaining a surface figure accuracy in terms of surface figure error of not more than one-fifteenth of wave peak-to-valley.
Ultra-low roughness magneto-rheological finishing for EUV mask substrates
NASA Astrophysics Data System (ADS)
Dumas, Paul; Jenkins, Richard; McFee, Chuck; Kadaksham, Arun J.; Balachandran, Dave K.; Teki, Ranganath
2013-09-01
EUV mask substrates, made of titania-doped fused silica, ideally require sub-Angstrom surface roughness, sub-30 nm flatness, and no bumps/pits larger than 1 nm in height/depth. To achieve the above specifications, substrates must undergo iterative global and local polishing processes. Magnetorheological finishing (MRF) is a local polishing technique which can accurately and deterministically correct substrate figure, but typically results in a higher surface roughness than the current requirements for EUV substrates. We describe a new super-fine MRF® polishing fluid whichis able to meet both flatness and roughness specifications for EUV mask blanks. This eases the burden on the subsequent global polishing process by decreasing the polishing time, and hence the defectivity and extent of figure distortion.
Searching the Polish Medical Bibliography (Polska Bibliografia Lekarska) for trials.
Almerie, Muhammad Qutayba; Matar, Hosam El-Din; Jones, Vicki; Kumar, Ajit; Wright, Judith; Wlostowska, Ewa; Adams, Clive E
2007-12-01
The Polish Medical Bibliography (Polska Bibliografia Lekarska) contains 350 000 records dating from 1979. These records from the fields of medicine, nursing, dentistry, health care systems and preclinical sciences are from nearly 300 biomedical journals published in Poland. We systematically searched the Polish Medical Bibliography Part II (1996-2006) CD-ROM (July 2006) using both English and Polish phrases for randomized trials, manually checked results and, for the trials identified in this way, sought these on medline and embase. Systematic searching identified records of 680 randomized trials from all areas of health care. Nearly 40% of these were not found on either medline or embase. The Polish Medical Bibliography should be of interest to health care information specialists concerned with comprehensive searches for trials.
Effects of nail polish on microbial growth of fingernails. Dispelling sacred cows.
Baumgardner, C A; Maragos, C S; Walz, J; Larson, E
1993-07-01
Nail polish worn on short, healthy nails does not appear to be associated with increased microbial counts on the fingernails. Additional studies to examine the effect of wearing nail polish on other aspects of hand hygiene may be warranted, however.
Polishing and toothbrushing alters the surface roughness and gloss of composite resins.
Kamonkhantikul, Krid; Arksornnukit, Mansuang; Takahashi, Hidekazu; Kanehira, Masafumi; Finger, Werner J
2014-01-01
This study aimed to investigate the surface roughness and gloss of composite resins after using two polishing systems and toothbrushing. Six composite resins (Durafill VS, Filtek Z250, Filtek Z350 XT, Kalore, Venus Diamond, and Venus Pearl) were evaluated after polishing with two polishing systems (Sof-Lex, Venus Supra) and after toothbrushing up to 40,000 cycles. Surface roughness (Ra) and gloss were determined for each composite resin group (n=6) after silicon carbide paper grinding, polishing, and toothbrushing. Two-way ANOVA indicated significant differences in both Ra and gloss between measuring stages for the composite resins tested, except Venus Pearl, which showed significant differences only in gloss. After polishing, the Filtek Z350 XT, Kalore, and Venus Diamond showed significant increases in Ra, while all composite resin groups except the Filtek Z350 XT and Durafill VS with Sof-Lex showed increases in gloss. After toothbrushing, all composite resin demonstrated increases in Ra and decreases in gloss.
Consensus Conference Findings on Supragingival and Subgingival Air Polishing.
Cobb, Charles M; Daubert, Diane M; Davis, Karen; Deming, Jodi; Flemmig, Thomas F; Pattison, Anna; Roulet, Jean-François; Stambaugh, Roger V
2017-02-01
A consensus conference was convened to evaluate and address issues of safety and efficacy when using glycine powder in an air-powder jet device for supra- and subgingival applications during dental prophylaxis and periodontal maintenance. The conference reported the following conclusions: 1) Supra- and subgingival air polishing using glycine powder is safe and effective for removal of biofilms from natural tooth structure and restorative materials; 2) there is no evidence of soft-tissue abrasion when using glycine powder in an air-polishing device; 3) in periodontal probing depths of 1 mm to 4 mm, glycine-powder air polishing, using a standard air-polishing nozzle, is more effective at removing subgingival biofilm than manual or ultrasonic instruments; and 4) at probing depths of 5 mm to 9 mm, using a subgingival nozzle, glycine powder air polishing is more effective at removing subgingival biofilm than manual or ultrasonic instrumentation. This conference statement, supported by an industry grant, was drafted by a panel of distinguished dental professionals.
Rigidity controllable polishing tool based on magnetorheological effect
NASA Astrophysics Data System (ADS)
Wang, Jia; Wan, Yongjian; Shi, Chunyan
2012-10-01
A stable and predictable material removal function (MRF) plays a crucial role in computer controlled optical surfacing (CCOS). For physical contact polishing case, the stability of MRF depends on intimate contact between polishing interface and workpiece. Rigid laps maintain this function in polishing spherical surfaces, whose curvature has no variation with the position on the surface. Such rigid laps provide smoothing effect for mid-spatial frequency errors, but can't be used in aspherical surfaces for they will destroy the surface figure. Flexible tools such as magnetorheological fluid or air bonnet conform to the surface [1]. They lack rigidity and provide little natural smoothing effect. We present a rigidity controllable polishing tool that uses a kind of magnetorheological elastomers (MRE) medium [2]. It provides the ability of both conforming to the aspheric surface and maintaining natural smoothing effect. What's more, its rigidity can be controlled by the magnetic field. This paper will present the design, analysis, and stiffness variation mechanism model of such polishing tool [3].
REOSC Delivers the Best Astronomical Mirror in the World to ESO
NASA Astrophysics Data System (ADS)
1999-12-01
On December 14, 1999, REOSC , the Optical Department of the SAGEM Group , finished the polishing of the fourth 8.2-m main mirror for the Very Large Telescope (VLT) of the European Southern Observatory. The mirror was today delivered to ESO at a ceremony at the REOSC factory in Saint Pierre du Perray, just south of Paris. The precision of the form of the mirror that was achieved during the polishing process is 8.5 nanometer (1 nanometer = 1 millionth of a millimetre) over the optical surface. This exceptional value corresponds to an optical resolution (theoretical image sharpness) of 0.03 arcseconds in the visible spectrum. This corresponds to distinguishing two objects separated by only 15 cm at a distance of 1000 km and will allow to detect astronomical objects that are 10,000 million times fainter than what can be perceived with the unaided eye. This impressive measure of quality, achieved by the REOSC teams during much painstaking work, implies that this VLT mirror is the most accurate in the world. In fact, all four 8.2-m VLT main mirrors polished by REOSC are well within the very strict specifications set by ESO, but this is the best of them all. The celebration today is the successful highlight of a contract initiated more than ten years ago, during which REOSC has perfected new polishing and control techniques - innovations improved and developed in a unique workshop dedicated to these giant mirrors. These methods and means are directly applicable to the new generations of segmented mirrors that are now being developed for astronomy and space observations. They are, in this sense, at the foremost front of optical technology. REOSC, the Optical Department of the SAGEM Group , is specialised in the study and realisation of high-precision optics for astronomy, space, defence, science and industry. For earlier information about the work on the VLT mirrors, cf. ESO Press Release 15/95 (13 November 1995). The SAGEM Group is a French high-technology group. It employs about 15,500 people - more information is available at URL: www.sagem.com. Information about the ESO and the VLT project is available via the ESO website: www.eso.org. Some Key Dates The polishing at REOSC of the main mirrors for the four VLT Unit Telescopes has been a major industrial feat. Here are some of the main dates: July 1989 ESO and REOSC sign contract for the polishing of the four 8.2-m and various associated activities July 1989 - April 1992 Design activities, construction of REOSC production plant April 1992 Mirror Container and concrete dummy mirror blank completed - test transport May 1992 Inauguration of REOSC production plant July 1993 Delivery of first 8.2-m mirror blank to ESO at Schott Glaswerke AG (Mainz, Germany) October 1994 Delivery of second 8.2-m mirror blank to ESO at Schott Glaswerke AG September 1995 Delivery of third 8.2-m mirror blank to ESO at Schott Glaswerke AG May 1996 Acceptance by ESO of first polished mirror at REOSC September 1996 Delivery of fourth 8.2-m mirror blank to ESO at Schott Glaswerke AG October 1996 Acceptance by ESO of second polished mirror at REOSC June 1997 Acceptance by ESO of third polished mirror at REOSC October - December 1997 Transport and delivery of first mirror to Paranal by Gondrand (France) August - September 1998 Transport and delivery of second mirror to Paranal by Gondrand December 1998 - January 1999 Transport and delivery of third mirror to Paranal by Gondrand December 1999 Acceptance by ESO of fourth polished mirror at REOSC February 1999 - April 2000 Transport and delivery of fourth mirror to Paranal by Gondrand Note [1] A Press Release on the REOSC event and the delivery of the fourth VLT main mirror to ESO is also published by SAGEM (in French and English). How to obtain ESO Press Information ESO Press Information is made available on the World-Wide Web (URL: http://www.eso.org../ ). ESO PR Photo 44/99 may be reproduced, if credit is given to SAGEM and the European Southern Observatory.
Sudha, Vasudevan; Spiegelman, Donna; Hong, Biling; Malik, Vasanti; Jones, Clara; Wedick, Nicole M; Hu, Frank B; Willett, Walter; Bai, Mookambika Ramya; Ponnalagu, Muthu Mariyammal; Arumugam, Kokila; Mohan, Viswanathan
2013-01-01
To study consumer acceptance of unmilled brown and undermilled rice among urban south Indians. Overweight and normal weight adults living in slum and nonslum residences in Chennai participated (n = 82). Bapatla (BPT) and Uma (red pigmented) rice varieties were chosen. These rice varieties were dehusked (unmilled, 0% polish) and further milled to 2.3% and 4.4% polishing (undermilled). Thus, 9 rice samples in both raw and parboiled forms were provided for consumer tasting over a period of 3 days. A 7-point hedonic scale was used to rate consumer preferences. A validated questionnaire was used to collect demographic, anthropometric, medical history, physical activity, dietary intake data, and willingness of the consumers to switch over to brown rice. Consumers reported that the color, appearance, texture, taste, and overall quality of the 4.4% polished rice was strongly preferred in both varieties and forms. Ratings for 0% polished (brown rice) were substantially lower than those of 2.3% polished rice, which were intermediate in ratings between 0% and 4.4% polishing. However, most of the consumers (93%) expressed a willingness to substitute brown or 2.3% polished rice, if affordable, after the taste tests and education on nutritional and health benefits of whole grains. Though most consumers preferred polished white rice, education regarding health benefits may help this population switch to brown or undermilled rice. Cooking quality and appearance of the grains were perceived as the most important factors to consider when purchasing rice among Chennai urban adults.
Ion-beam technology and applications
NASA Technical Reports Server (NTRS)
Hudson, W. R.; Robson, R. R.; Sovey, J. S.
1977-01-01
Ion propulsion research and development yields a mature technology that is transferable to a wide range of nonpropulsive applications, including terrestrial and space manufacturing. A xenon ion source was used for an investigation into potential ion-beam applications. The results of cathode tests and discharge-chamber experiments are presented. A series of experiments encompassing a wide range of potential applications is discussed. Two types of processes, sputter deposition, and erosion were studied. Some of the potential applications are thin-film Teflon capacitor fabrication, lubrication applications, ion-beam cleaning and polishing, and surface texturing.
Electro-Chemical-Mechanical, Low Stress, Automatic Polishing (ECMP) Device (Preprint)
2010-01-01
into models that predict mechanical response [ 4 - 6 ]. In addition, surface preparation steps are critical to the imaging of ceramic and hybrid...2p 3/2 peak in the spectral data found in Figure 4 . The Ti 2p 3/2 peak is initially observed at 458.4 eV indicating that titanium is present in its...above 6 acceptable limits for both (average IQ values were higher than 2000). For the titanium samples, the samples processed without applied
1991-09-11
signal did not vary on side B when the laser beam was incident on different regions of the surface. The absorption was the same when examining a...silica and zerodur I have been polished using this technique. Float polished substrates have a typical surface roughness of approximately 2 A, with a
ERIC Educational Resources Information Center
Defense Language Inst., Washington, DC.
These 15 volumes of the Basic Polish Course, prepared for use in the Defense Language Institute's intensive language program, comprise Lessons 1-124. They are disigned to train native English language speakers to Level 3 proficiency in comprehension, speaking, reading, and writing Polish. (Level 5 is native-speaker fluency.) The phonological…
Development of small solid rocket boosters for the ILR-33 sounding rocket
NASA Astrophysics Data System (ADS)
Nowakowski, Pawel; Okninski, Adam; Pakosz, Michal; Cieslinski, Dawid; Bartkowiak, Bartosz; Wolanski, Piotr
2017-09-01
This paper gives an overview of the development of a 6000 Newton-class solid rocket motor for suborbital applications. The design configuration and results of interior ballistics calculations are given. The initial use of the motor as the main propulsion system of the H1 experimental in-flight test platform, within the Polish Small Sounding Rocket Program, is presented. Comparisons of theoretical and experimental performance are shown. Both on-ground and in-flight tests are discussed. A novel composite-case manufacturing technology, which enabled to reach high propellant mass fractions, was validated and significant cost-reductions were achieved. This paper focuses on the process of adapting the design for use as the booster stage of the ILR-33 sounding rocket, under development at the Institute of Aviation in Warsaw, Poland. Parallel use of two of the flight-proven rocket motors along with the main stage is planned. The process of adapting the rocket motor for booster application consists of stage integration, aerothermodynamics and reliability analyses. The separation mechanism and environmental impact are also discussed within this paper. Detailed performance analysis with focus on propellant grain geometry is provided. The evolution of the design since the first flights of the H1 rocket is covered and modifications of the manufacturing process are described. Issues of simultaneous ignition of two motors and their non-identical performance are discussed. Further applications and potential for future development are outlined. The presented results are based on the initial work done by the Rocketry Group of the Warsaw University of Technology Students' Space Association. The continuation of the Polish Small Sounding Rocket Program on a larger scale at the Institute of Aviation proves the value of the outcomes of the initial educational project.
Effect of surface pre-treatments on biocompatibility of magnesium.
Lorenz, Carla; Brunner, Johannes G; Kollmannsberger, Philip; Jaafar, Leila; Fabry, Ben; Virtanen, Sannakaisa
2009-09-01
This study reports the influence of Mg surface passivation on the survival rate of human HeLa cells and mouse fibroblasts in cell culture experiments. Polished samples of commercially pure Mg show high reactivity in the cell culture medium, leading to a pH shift in the alkaline direction, and therefore cell adhesion and survival is strongly impaired. Passivation of the Mg surface in 1M NaOH can strongly enhance cell survival. The best initial cell adhesion is observed for Mg samples incubated in simulated body fluid (M-SBF), which leads to the formation of a biomimetic, amorphous Ca/Mg-phosphate layer with high surface roughness. This surface layer, however, passivates and seals the Mg surface only partially. Subsequent Mg dissolution leads to a significantly stronger pH increase compared to NaOH-passivated samples, which prevents long-term cell survival. These results demonstrate that surface passivation with NaOH and M-SBF together with the associated changes of surface reactivity, chemistry and roughness provide a viable strategy to facilitate cell survival on otherwise non-biocompatible Mg surfaces.
Polish Americans. Second, Revised Edition.
ERIC Educational Resources Information Center
Lopata, Helen Znaniecka
This book examines Polonia, the Polish ethnic community in America created by three giant waves of immigration between 1880 and 1990. The complicated history of this ethnic group is reflected in the lives of increasing numbers of Polish Americans, including recent immigrants brought by political and economic changes, as they achieve middle class…
This abstract describes a pilot-scale evaluation of anaerobic biological perchlorate (C1O4) removal followed by aerobic effluent polishing. The anaerobic biological contactor operated for 3.5 years. During that period, two effluent polishing evaluations, lasting 311 an...
This abstract describes a pilot-scale evaluation of anaerobic biological perchlorate (C1O4) removal followed by aerobic effluent polishing. The anaerobic biological contactor operated for 3.5 years. During that period, two effluent polishing evaluations, lasting 311 an...
Takizawa, Ken; Beaucamp, Anthony
2017-09-18
A new category of circular pseudo-random paths is proposed in order to suppress repetitive patterns and improve surface waviness on ultra-precision polished surfaces. Random paths in prior research had many corners, therefore deceleration of the polishing tool affected the surface waviness. The new random path can suppress velocity changes of the polishing tool and thus restrict degradation of the surface waviness, making it suitable for applications with stringent mid-spatial-frequency requirements such as photomask blanks for EUV lithography.
Evaluating a vessel for suitability for containing fluid
Barefield, II, James E.; Judge, Elizabeth J.; Le, Loan A.; Lopez, Leon N.; Beveridge, Andrew C.; Chapman, Daniel R.; Taylor, Seth T.
2017-05-30
A method for evaluating a vessel for suitability to contain a fluid includes providing a vessel and forming a polished surface portion of the vessel by removing oxidation and/or contaminants from a portion of the vessel. The method further includes applying a focused laser to the polished surface portion to form plasma on the polished surface portion, and determining whether the vessel is suitable for containing a fluid based on silicon content of the polished surface portion. The silicon content is estimated based on light emitted from the plasma.
NASA Astrophysics Data System (ADS)
Jianxiu, Su; Xiqu, Chen; Jiaxi, Du; Renke, Kang
2010-05-01
Distribution forms of abrasives in the chemical mechanical polishing (CMP) process are analyzed based on experimental results. Then the relationships between the wafer, the abrasive and the polishing pad are analyzed based on kinematics and contact mechanics. According to the track length of abrasives on the wafer surface, the relationships between the material removal rate and the polishing velocity are obtained. The analysis results are in accord with the experimental results. The conclusion provides a theoretical guide for further understanding the material removal mechanism of wafers in CMP.
Reel-to-reel substrate tape polishing system
Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei
2005-06-21
Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.
Syroka, Bozena Płonka
2006-01-01
The issue of presence of doctors of Jewish origin in Polish medical community is the subject of research presented in this article. The author describes the most important personalities originating from this national group, who had the biggest contribution to Polish modern times medical life. The process of Jewish minority assimilation to Polish culture in 18th and 19th centuries is outlined, as well as its effects in reborn Poland. Also, the Jewish minority situation during the Second World War is describes, and the harm they suffered then. Against this background the author shows the anti-Semitic trends visible in Polish political life in times of Polish People's Republic, especially during the 1968 upheavals, which greatly contributed to the fact that many doctors of medicine of Jewish origin emigrated from Poland for political reasons.
Sierpińska, Lidia
2013-09-01
The Authentic Leadership Questionnaire (ALQ) is a standardized research instrument for the evaluation of individual elements of leader's conduct which contribute to the authentic leadership. The application of this questionnaire in Polish conditions required to carry out the validation process. The aim of the study was to evaluate of validity and reliability of the Polish version of the American research instrument for the needs of evaluation of authenticity of leadership of the nursing management in Polish hospitals. The study covered 286 nurses (143 head nurses and 143 of their subordinates) employed in 45 hospitals in Poland. Theoretical validity of the instrument was evaluated using Fisher's transformation (r-Person correlation coefficient), while the criterion validity of the ALQ was evaluated using rho-Spearman correlation coefficient and the BOHIPSZO questionnaire. The reliability of the ALQ was assessed by means of the Cronbach-alpha coefficient. The ALQ questionnaire applied for the evaluation of authenticity of leadership of the nursing management in Polish hospital wards shows an acceptable theoretical and criterion validity and reliability (Cronbach-alpha coefficient 0.80). The Polish version of the ALQ is valid and reliable, and may be applied in studies concerning the evaluation of authenticity of leadership of the nursing management in Polish hospital wards.
Peano-like paths for subaperture polishing of optical aspherical surfaces.
Tam, Hon-Yuen; Cheng, Haobo; Dong, Zhichao
2013-05-20
Polishing can be more uniform if the polishing path provides uniform coverage of the surface. It is known that Peano paths can provide uniform coverage of planar surfaces. Peano paths also contain short path segments and turns: (1) all path segments have the same length, (2) path segments are mutually orthogonal at the turns, and (3) path segments and turns are uniformity distributed over the domain surface. These make Peano paths an attractive candidate among polishing tool paths because they enhance multidirectional approaches of the tool to each surface location. A method for constructing Peano paths for uniform coverage of aspherical surfaces is proposed in this paper. When mapped to the aspherical surface, the path also contains short path segments and turns, and the above attributes are approximately preserved. Attention is paid so that the path segments are still well distributed near the vertex of the surface. The proposed tool path was used in the polishing of a number of parabolic BK7 specimens using magnetorheological finishing (MRF) and pitch with cerium oxide. The results were rather good for optical lenses and confirm that a Peano-like path was useful for polishing, for MRF, and for pitch polishing. In the latter case, the surface roughness achieved was 0.91 nm according to WYKO measurement.
NASA Astrophysics Data System (ADS)
Menapace, J. A.; Ehrmann, P. R.; Bickel, R. C.
2009-10-01
Over the past year we have been working on specialized MR fluids for polishing KDP crystals. KDP is an extremely difficult material to conventionally polish due to its water solubility, low hardness, and temperature sensitivity. Today, KDP crystals are finished using single-point diamond turning (SPDT) tools and nonaqueous lubricants/coolants. KDP optics fabricated using SPDT, however, are limited to surface corrections due to tool/method characteristics with surface quality driven by microroughness from machine pitch, speed, force, and diamond tool character. MRF polishing offers a means to circumvent many of these issues since it is deterministic which makes the technique practical for surface and transmitted wavefront correction, is low force, and is temperature independent. What is lacking is a usable nonaqueous MR fluid that is chemically and physically compatible with KDP which can be used for polishing and subsequently cleaned from the optical surface. In this study, we will present the fluid parameters important in the design and development of nonaqueous MR fluid formulations capable of polishing KDP and how these parameters affect MRF polishing. We will also discuss requirements peculiar to successful KDP polishing and how they affect optical figure/finish and laser damage performance at 1064 nm and 532 nm.
Analysis of the Material Removal Rate in Magnetic Abrasive Finishing of Thin Film Coated Pyrex Glass
NASA Astrophysics Data System (ADS)
Lee, Hee Hwan; Lee, Seoung Hwan
The material removal rate (MRR) during precision finishing/polishing is a key factor, which dictates the process performance. Moreover, the MRR or wear rate is closely related to the material/part reliability. For nanoscale patterning and/or planarization on nano-order thickness coatings, the prediction and in-process monitoring of the MRR is necessary, because the process is not characterizable due to size effects and material property/process condition variations as a result of the coating/substrate interactions. The purpose of this research was to develop a practical methodology for the prediction and in-process monitoring of MRR during nanoscale finishing of coated surfaces. Using a specially designed magnetic abrasive finishing (MAF) and acoustic emission (AE) monitoring setup, experiments were carried out on indium-zinc-oxide (IZO) coated Pyrex glasses. After a given polishing time interval, AFM indentation was conducted for each workpiece sample to measure the adhesion force variations of the coating layers (IZO), which are directly related to the MRR changes. The force variation and AE monitoring data were compared to the MRR calculated form the surface measurement (Nanoview) results. The experimental results demonstrate strong correlations between AFM indentation and MRR measurement data. In addition, the monitored AE signals show sensitivity of the material structure variations of the coating layer, as the polishing progresses.
NASA Astrophysics Data System (ADS)
Diehl, Stefan; Bremer, Daniel; Brinkmann, Kai-Thomas; Dormenev, Valery; Eissner, Tobias; Novotny, Rainer W.; Rosenbaum, Christoph; Zaunick, Hans-Georg; PANDA Collaboration
2017-06-01
The uniformity of the light collection is a crucial parameter for detectors based on inorganic scintillation crystals to guarantee a response proportional to the deposited energy. Especially in case of tapered crystals, like they are widely used to realize a 4π geometry of electromagnetic calorimeters (EMC) in high energy physics experiments, a strong non-uniformity is introduced by an additional focusing of the scintillation light due to the tapered geometry. The paper will discuss the determination and the reduction of the non-uniformity in strongly tapered lead tungstate crystals as used for the construction of the electromagnetic calorimeter of the PANDA detector at the future Facility for Antiproton and Ion Research (FAIR). Among different concepts for an uniformization a single de-polished lateral side face provided the optimum result with a remaining non-uniformity below 5% in good agreement with similar studies for the CMS ECAL at LHC. The impact on the achievable energy resolution in the energy regime of photons below 800 MeV is discussed in detail in comparison to GEANT4 simulations. The comparison of the response of two arrays with polished and de-polished crystals, respectively, shows in the latter case a significant improvement of the constant term of the parametrization of the energy resolution down to 0.5% accompanied by only very slight increase of the statistical term.
NASA Astrophysics Data System (ADS)
Zhong, Xianyun; Fan, Bin; Wu, Fan
2017-08-01
The corrective calibration of the removal function plays an important role in the magnetorheological finishing (MRF) high-accuracy process. This paper mainly investigates the asymmetrical characteristic of the MRF removal function shape and further analyzes its influence on the surface residual error by means of an iteration algorithm and simulations. By comparing the ripple errors and convergence ratios based on the ideal MRF tool function and the deflected tool function, the mathematical models for calibrating the deviation of horizontal and flowing directions are presented. Meanwhile, revised mathematical models for the coordinate transformation of an MRF machine is also established. Furthermore, a Ø140-mm fused silica plane and a Ø196 mm, f/1∶1, fused silica concave sphere samples are taken as the experiments. After two runs, the plane mirror final surface error reaches PV 17.7 nm, RMS 1.75 nm, and the polishing time is 16 min in total; after three runs, the sphere mirror final surfer error reaches RMS 2.7 nm and the polishing time is 70 min in total. The convergence ratios are 96.2% and 93.5%, respectively. The spherical simulation error and the polishing result are almost consistent, which fully validate the efficiency and feasibility of the calibration method of MRF removal function error using for the high-accuracy subaperture optical manufacturing.
ERIC Educational Resources Information Center
Mizell, Hayes
2009-01-01
Staff development's brand is tarnished. Many of its consumers are not satisfied. Some are angry. Others are resigned to accepting professional development as it is because they lack the will or power or knowledge to change it. Educators respond in these ways because their staff development experiences are often shallow and do little to help them…
The Use of Articles in L2 English: A Phraseological Perspective
ERIC Educational Resources Information Center
Lesniewska, Justyna
2016-01-01
While it is a well-known fact that speakers of article-less mother tongues, such as Polish, experience problems with articles in English, this study seeks to investigate the problem from a different perspective. Namely, it poses the question of whether the correct use of the article system of the L2 is indeed a purely grammatical task (as it is…
NASA Astrophysics Data System (ADS)
Wasilewska, Marta
2017-10-01
This paper presents the comparison of skid resistance of wearing course made of SMA (Stone Mastic Asphalt) mixtures which differ in resistance to polishing of coarse aggregate. Dolomite, limestone, granite and trachybasalt were taken for investigation. SMA mixtures have the same nominal size of aggregate (11 mm) and very similar aggregate particle-size distribution in mineral mixtures. Tested SMA11 mixtures were designed according to EN 13108-5 and Polish National Specification WT-2: 2014. Evaluation of the skid resistance has been performed using the FAP (Friction After Polishing) test equipment also known as the Wehner/Schulze machine. Laboratory method enables to compare the skid resistance of different types of mixtures under specified conditions simulating polishing processes. Tests were performed on both the specimens made of each coarse aggregate and SMA11 mixtures containing these aggregates. Measuring of friction coefficient μm was conducted before and during polishing process up to 180 0000 passes of polishing head. Comparison of the results showed differences in sensitivity to polishing among particular mixtures which depend on the petrographic properties of rock used to produce aggregate. Limestone and dolomite tend to have a fairly uniform texture with low hardness which makes these rock types susceptible to rapid polishing. This caused lower coefficient of friction for SMA11 mixtures with limestone and dolomite in comparison with other test mixtures. These significant differences were already registered at the beginning of the polishing process. Limestone aggregate had lower value of μm before starting the process than trachybasalt and granite aggregate after its completion. Despite the differences in structure and mineralogical composition between the granite and trachybasalt, slightly different values of the friction coefficient at the end of polishing were obtained. Images of the surface were taken with the optical microscope for better understanding of the phenomena occurring on the surface of specimen. Results may be valuable information when selecting aggregate to asphalt mixtures at the stage of its design and maintenance of existing road pavements.
Bertoldo, Carlos; Lima, Debora; Fragoso, Larissa; Ambrosano, Glaucia; Aguiar, Flavio; Lovadino, Jose
2014-01-01
The microabrasion technique of enamel consists of selectively abrading the discolored areas or causing superficial structural changes in a selective way. In microabrasion technique, abrasive products associated with acids are used, and the evaluation of enamel roughness after this treatment, as well as surface polishing, is necessary. This in-vitro study evaluated the enamel roughness after microabrasion, followed by different polishing techniques. Roughness analyses were performed before microabrasion (L1), after microabrasion (L2), and after polishing (L3).Thus, 60 bovine incisive teeth divided into two groups were selected (n=30): G1- 37% phosphoric acid (37%) (Dentsply) and pumice; G2- hydrochloric acid (6.6%) associated with silicon carbide (Opalustre - Ultradent). Thereafter, the groups were divided into three sub-groups (n=10), according to the system of polishing: A - Fine and superfine granulation aluminum oxide discs (SofLex 3M); B - Diamond Paste (FGM) associated with felt discs (FGM); C - Silicone tips (Enhance - Dentsply). A PROC MIXED procedure was applied after data exploratory analysis, as well as the Tukey-Kramer test (5%). No statistical differences were found between G1 and G2 groups. L2 differed statistically from L1 and showed superior amounts of roughness. Differences in the amounts of post-polishing roughness for specific groups (1A, 2B, and 1C) arose, which demonstrated less roughness in L3 and differed statistically from L2 in the polishing system. All products increased enamel roughness, and the effectiveness of the polishing systems was dependent upon the abrasive used.
Lay beliefs on Polish oncology in the evaluation of healthy individuals.
Synowiec-Piłat, Małgorzata
2017-12-23
Poland is among the countries which reported the highest rates of mortality from cancer. The health behaviours of people are influenced, among other things, by their beliefs about cancer, but their evaluation of oncological institutions and specialists seems also to be of great importance. Objectives. 1. How the respondents evaluate Polish oncology: a) the conditions of treatment in oncology hospitals, b) access to oncological medical services, c) the competence of oncologists. 2. What are the socio-cultural factors of the assessment of Polish oncology? 3. What is the influence of the grade level of the assessment of Polish oncology on the degree of fear and the knowledge about cancer? The study was carried out with a sample of 910 adult residents of Wroclaw in south-west Poland. Quota sampling was used. An interview questionnaire was used as the method. Analysis of the data showed a negative image of Polish oncology, according to the study participants: dissatisfaction with both treatment conditions and with access to medical services. Assessment of Polish oncology depends primarily on education, age and economic situation, as well as 'family history of cancer', and attitude towards doctors. The lower the rating of Polish oncology, the lower the medical knowledge, and the higher the level of fear of cancer. Negative assessment of Polish oncology perpetuates the fear of cancer in society. There is a need for constant improvement of the quality of medical oncology services, for building public trust in physicians, to fight inequalities in health, and to take into account the lay perspectives in developing strategies to combat cancer.
Buss, Tomasz; Kruk, Agnieszka; Wiśniewski, Piotr; Modlinska, Aleksandra; Janiszewska, Justyna; Lichodziejewska-Niemierko, Monika
2014-10-01
Multidimensional questionnaires estimating cancer-related fatigue (CRF) as a symptom cluster or a clinical syndrome primarily have been used and validated in English-speaking populations. However, cultural issues and language peculiarities can affect CRF assessment The main aims of this study were to evaluate the psychometric properties of the Polish version of the Multidimensional Fatigue Inventory-20 (MFI-20) and to deliver to clinicians a multidimensional tool for CRF assessment in Polish-speaking patients with cancer. After forward-backward translation procedures, the Polish version of MFI-20 was administered to 340 cancer patients. The Polish MFI-20 was appraised in terms of acceptability, reliability, and validity. Internal consistency was assessed by calculating Cronbach's alpha coefficients. Structural validity was evaluated with confirmatory factor analysis. The translated MFI-20 was well accepted; 90% of subjects fully completed the questionnaire. The overall Cronbach's alpha coefficient was 0.9, ranging from 0.57 to 0.81. All correlation coefficients among Numeric Rating Scale-fatigue, fatigue-related items from the European Organization for Research and Treatment of Cancer Quality of Life Core-30 questionnaire, and the MFI--20 were statistically significant (P < 0.001). Confirmatory factor analysis demonstrated good structural validity and revealed only three dimensions in the Polish version of the MFI-20-physical and mental fatigue as well as reduced motivation. The Polish version of the MFI-20 is well accepted by patients, reliable, and a valid instrument to assess CRF in Polish cancer patients. Copyright © 2014 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
Sudha, Vasudevan; Spiegelman, Donna; Hong, Biling; Malik, Vasanti; Jones, Clara; Wedick, Nicole M.; Hu, Frank B.; Willett, Walter; Bai, Mookambika Ramya; Ponnalagu, Muthu Mariyammal; Arumugam, Kokila; Mohan, Viswanathan
2013-01-01
Objectives To study consumer acceptance of unmilled brown and under milled rice among urban south Indians. Methods Overweight and normal weight adults living in slum and non-slum residences in Chennai participated (n=82). Bapatla (BPT) and Uma (red pigmented) rice varieties were chosen. These rice varieties were dehusked (unmilled, 0% polish) and further milled to 2.3% and 4.4% polishing (under milled). Thus nine rice samples in both raw and parboiled forms were provided for consumer tasting over a period of three days. A hedonic 7-point scale was used to rate the consumer preferences. A validated questionnaire was used to collect demographic, anthropometric, medical history, physical activity, dietary intake data and willingness of the consumers to switch over to brown rice. Results Consumers reported that the color, appearance, texture, taste and overall quality of the 4.4% polished rice was strongly preferred in both varieties and forms. Ratings for 0% polished (brown rice) were substantially lower than those of 2.3% polished rice, which were intermediate in ratings between 0% and 4.4% polishing. However, most of the consumers (93%) expressed willingness to substitute brown or 2.3% polished rice if affordable after the taste tests and education on nutritional and health benefits of whole grains. Conclusion While most consumers’ preferred polished white rice, education regarding health benefits may help this population switch to brown or under milled rice. Cooking quality and appearance of the grains were perceived as the most important factors to consider when purchasing rice among Chennai urban adults. PMID:24015699
Evolution of surface characteristics in material removal simulation with subaperture tools
NASA Astrophysics Data System (ADS)
Kim, Sug-Whan; Jee, Myung-Kook
2002-02-01
Over the last decade, we have witnessed that the fabrication of 200 - 2000 mm scale have received relatively little attention from the fabrication technology development, compared to those of smaller than 200 mm and of larger than 2000 mm in diameter. As a result, the optical surfaces of these scales are still predominantly completed by small optics shops where opticians apply the traditional technique for polishing. Lack of tools in aiding opticians for planning, executing and analyzing their polishing work is a root cause for long and, sometimes, unpredictable delivery and high manufacturing cost for such optical surfaces. We present the on-going development of a software simulation environment called Surface Analysis and Fabrication Environment (SAFE). It is primarily intended to increase the throughput of polishing and testing cycles by allowing opticians to simulate the resulting surface form and roughness with input polishing variables. A brief review of current polishing techniques and their target optics clarifies the need for such simulation tool. This is followed by the development targets and a preliminary simulation plan using the developmental version of SAFE. Among many polishing variables, two removal assumptions and three different types of removal functions we used for the polishing simulation presented. The simulations show that the Gaussian removal function with the proportional removal assumption resulted in the fastest, though marginal, convergence to a super-polished surface of 0.56 micron Peat- to-Valley in form accuracy and of 0.02 nanometer in surface roughness Ra. Other meaningful results and their implications are also presented.
NASA Astrophysics Data System (ADS)
Sugawara, Jun; Kamiya, Tomohiro; Mikashima, Bumpei
2017-09-01
Ultra-low thermal expansion ceramics NEXCERATM is regarded as one of potential candidate materials crucial for ultralightweight and thermally-stable optical mirrors for space telescopes which are used in future optical missions satisfying extremely high observation specifications. To realize the high precision NEXCERA mirrors for space telescopes, it is important to develop a deterministic aspheric shape polishing and a precise figure correction polishing method for the NEXCERA. Magnetorheological finishing (MRF) was tested to the NEXCERA aspheric mirror from best fit sphere shape, because the MRF technology is regarded as the best suited process for a precise figure correction of the ultralightweight mirror with thin sheet due to its advantage of low normal force polishing. As using the best combination of material and MR fluid, the MRF was performed high precision figure correction and to induce a hyperbolic shape from a conventionally polished 100mm diameter sphere, and achieved the sufficient high figure accuracy and the high quality surface roughness. In order to apply the NEXCERA to a large scale space mirror, for the next step, a middle size solid mirror, 250 mm diameter concave parabola, was machined. It was roughly ground in the parabolic shape, and was lapped and polished by a computer-controlled polishing machine using sub-aperture polishing tools. It resulted in the smooth surface of 0.6 nm RMS and the figure accuracy of λ/4, being enough as pre-MRF surface. A further study of the NEXCERA space mirrors should be proceeded as a figure correction using the MRF to lightweight mirror with thin mirror sheet.
Strategy for development of the Polish electricity sector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dybowski, J.
1995-12-01
This paper represents the strategy for development of the Polish Electricity Sector dealing with specific problems which are common for all of East Central Europe. In 1990 Poland adopted a restructuring program for the entire energy sector. Very ambitious plans were changed several times but still the main direction of change was preserved. The most difficult period of transformation is featured by several contradictions which have to be balanced. Electricity prices should increase in order to cover the modernization and development program but the society is not able to take this burden in such a short time. Furthermore the newmore » environment protection standards force the growth of capital investment program which sooner or later has to be transferred through the electricity prices. New economic mechanisms have to be introduced to the electricity sector to replace the old ones noneffective, centrally planned. This process has to follow slow management changes. Also, introduction of new electricity market is limited by those constraints. However, this process of change would not be possible without parallel governmental initiation like preparation of new energy law and regulatory frames.« less
Laryngologist Leon Zamenhof--brother of Dr. Esperanto.
Wincewicz, Andrzej; Sulkowska, Mariola; Musiatowicz, Marcin; Sulkowski, Stanislaw
2009-06-01
To reconstruct the biography of the Polish otorhinolaryngologist Leon Zamenhof (1875-1934), a brother of Ludwik Zamenhof, who is famous for invention of the international language Esperanto. Biographical information was collected from pre-World War II resources. Zamenhof developed several important new forms of treatment to help the hearing impaired. Zamenhof was especially interested in the education of deaf children and the therapy necessary to facilitate their integration into society. His significant achievements were a phonetic method of therapy for the hearing impaired and an automatic device for ear insufflation that was considered indispensable in the management of pyorrhea. In addition, Zamenhof initiated various forms of social support among physicians within the medical community of Warsaw, Poland; made health care available to children with hearing impairments; and organized a Jewish school for deaf children. Zamenhof tried to change public attitudes toward deafness, working to promote the integration of the deaf into wider society. He also translated Polish literature into Esperanto. With similar aims to his brother Ludwik, Leon Zamenhof strived to enhance and broaden communication among people who could not hear and to persuade people to change their attitudes about deafness.
Characterization of chemical interactions during chemical mechanical polishing (CMP) of copper
NASA Astrophysics Data System (ADS)
Lee, Seung-Mahn
2003-10-01
Chemical mechanical polishing (CMP) has received much attention as an unique technique to provide a wafer level planarization in semiconductor manufacturing. However, despite the extensive use of CMP, it still remains one of the least understood areas in semiconductor processing. The lack of the fundamental understanding is a significant barrier to further advancements in CMP technology. One critical aspect of metal CMP is the formation of a thin surface layer on the metal surface. The formation and removal of this layer controls all the aspects of the CMP process, including removal rate, surface finish, etc. In this dissertation, we focus on the characterization of the formation and removal of the thin surface layer on the copper surface. The formation dynamics was investigated using static and dynamic electrochemical techniques, including potentiodynamic scans and chronoamperometry. The results were validated using XPS measurements. The mechanical properties of the surface layer were investigated using nanoindentation measurements. The electrochemical investigation showed that the thickness of the surface layer is controlled by the chemicals such as an oxidizer (hydrogen peroxide), a corrosion inhibitor (benzotriazole), a complexing agent (citric acid), and their concentrations. The dynamic electrochemical measurements indicated that the initial layer formation kinetics is unaffected by the corrosion inhibitors. The passivation due to the corrosion inhibitor becomes important only on large time scales (>200 millisecond). The porosity and the density of the chemically modified surface layer can be affected by additives of other chemicals such as citric acid. An optimum density of the surface layer is required for high polishing rate while at the same time maintaining a high degree of surface finish. Nanoindentation measurements indicated that the mechanical properties of the surface layer are strongly dependent on the chemical additives in the slurry. The CMP removal rates were found to be in good agreement with the initial reaction kinetics as well as the mechanical properties of the chemically modified surface layer. In addition, the material removal model based on the micro- and nano-scale interactions, which were measured experimentally, has been developed.
Mohammadi-Bassir, Mahshid; Babasafari, Mansoure; Rezvani, Mohammad Bagher; Jamshidian, Mahdieh
2017-11-01
Limited information is available for the best polishing systems and methods to obtain minimally abrasive monolithic zirconia surfaces after contouring and occlusal adjustment. The purpose of this in vitro study was to evaluate the effect of grinding and polishing procedures on the flexural strength, quality and quantity of surface roughness, topography, and phase transformation of a zirconia-based ceramic system. Fifty bar-shaped yttrium-stabilized zirconium oxide specimens (20×4×2 mm) were cut from presintered zirconia blanks. The specimens were wet-polished and divided into 5 groups (n=10): standard polishing without any surface treatment (group SP); grinding with a diamond rotary instrument (group Gr); grinding with a diamond rotary instrument (DRI) and over-glazing (group Gl); grinding with a DRI and polishing with an intraoral zirconia polishing kit in a 2-step procedure (group BP); and grinding with a DRI and polishing with an intraoral polishing kit (group MP). The Ra and Rz surface roughness values (μm) were measured with a profilometer. One specimen of each group was subjected to x-ray diffraction (XRD) to estimate the monoclinic phase and evaluated using scanning electron microscopy (SEM) for surface topography. The 3-point flexural strength of the bars was measured in a universal testing machine at a crosshead speed of 0.5 mm/min. The mean flexural strength (MPa) and surface roughness values were calculated, and the results were analyzed using 1-way ANOVA and Tukey honest significant difference tests (α=.05). Statistically significant differences were noted among the experimental groups for Ra, Rz (P<.001), and flexural strength values (P<.001). The highest Ra and Rz values were found in group Gr (P<.001) and the lowest in group Gl, which were significantly lower than the values in group Gr (P<.001). The 2 polishing systems (BP and MP) were not significantly different in terms of Ra and Rz values (P=.755 for Ra and P=.319 for Rz). The highest flexural strength was found in group Gr (283.35 ±49.85 MPa) without significant differences from those of MP and BP (P=.958 for BP and P=.404 for MP). The lowest flexural strength was found in Gl, which had no significant differences from those of the control group (P=1.000). In XRD the monoclinic phase was observed in Gr (26%), BP (24%), and MP (23%) groups. However, groups Gl and SP did not have any monoclinic phase. SEM showed deep unidirectional scratches after grinding that were smoothened by glazing and polishing. Roughness increased significantly after grinding, but polishing and glazing similarly diminished it. Glazing after grinding significantly decreased the flexural strength values, but polishing did not. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Tonakiewicz-Kolosowska, Anna; Socik, Iwona; Gajewska, Monika
2016-01-01
The authors present the development and perspectives of improving the quality of Information Literacy programmes in Polish technical universities, considering the Bologna Process and the general conditions of the Polish higher education system. The survey conducted in selected technical and medical universities provided an overview of changes…
On the Inclusive and Exclusive Functions of the "Other" Language in Family Talk
ERIC Educational Resources Information Center
Ogiermann, Eva
2013-01-01
The present study analyses bilingual conversations taking place in binational families living in the UK. The focus is on two Polish/English stepfamilies, where the Polish mothers' concern with preserving and developing their children's linguistic and cultural identity collides with the English partner's limited knowledge of Polish. While the paper…
Guide and Bibliography for Integrating Polish Studies into the Public School Curriculum.
ERIC Educational Resources Information Center
Wozniak, Albin S.
This bibliography contains citations to general and specific works on Polish Americans, their cultural and social roots, their history, literature and arts, and ethnic identity. A series of anthologies which deal with adaptation problems and the acculturation of Polish American groups are included. There are also references that provide guidelines…
Holocaust Education in Polish Public Schools: Between Remembrance and Civic Education
ERIC Educational Resources Information Center
Milerski, Boguslaw
2010-01-01
This article analyzes the historical and political context of Holocaust education, and its implementation in Polish schools. Perceptions of the Holocaust continue to change, influenced by Poland's social and political situation. The Polish historical context is quite specific; it includes the long history of Poles and Jews as neighbors, with local…
ERIC Educational Resources Information Center
Butler, Norman L.; Davidson, Barry S.; Pachocinski, Ryszard; Griffith, Kimberly Grantham; Kritsonis, William Allan
2007-01-01
This study compares Polish post-secondary vocational institutions with Canadian community colleges using an information technology conceptual framework. The research concentrated upon programs in information technology delivered by one Polish school Cracow School of Information Technology and two Canadian community colleges Durham (Oshawa,…
The Polish School System. Some Social and Historical Aspects.
ERIC Educational Resources Information Center
Holmberg, Carl, Ed.; Wojtowicz, Wit J., Ed.
A description of the Polish school-system and current educational research at the University of Gdansk (Poland) are included in this document. Articles included focus on two perspectives: (1) the social context in which schooling takes place; and (2) a historical outlook of the Polish system of education. Articles in this volume include:…
BEGINNING POLISH, VOLUME ONE. YALE LINGUISTIC SERIES.
ERIC Educational Resources Information Center
SCHENKER, ALEXANDER M.
BASED ON A MODERN LINGUISTIC ANALYSIS OF THE POLISH LANGUAGE, THIS TWO-VOLUME TEXT IS APPROPRIATE FOR A ONE-YEAR INTENSIVE COURSE. VOLUME I INCLUDES 25 LESSONS, EACH DIVIDED INTO--SENTENCES (DIALOGS), GRAMMAR, EXERCISES, AND VOCABULARY LISTS. THE INTRODUCTION PRESENTS A BRIEF CONTRASTIVE ANALYSIS OF POLISH AND RUSSIAN, AND THERE IS INCLUDED A…
Acoustic Correlates of Focus Marking in Czech and Polish.
Hamlaoui, Fatima; Żygis, Marzena; Engelmann, Jonas; Wagner, Michael
2018-05-01
Languages vary in the type of contexts that affect prosodic prominence. This paper reports on a production study investigating how different types of foci influence prosody in Polish and Czech noun phrases. The results show that in both languages, focus and givenness are marked prosodically, with pitch and intensity as the main acoustic correlates. Like Germanic languages, Polish and Czech patterns show prosodic focus marking in a broad range of contexts and differ in this regard from other fixed-word-stress languages such as French. This suggests that (a) Polish and Czech are similar to Germanic languages and are unlike Romance languages in marking a variety of types of focus prosodically; (b) there is no close correlation between fixed word stress and lack of prosodic focus marking because Polish, which has fixed stress on the penult, shows prosodic focus marking for all types of focus; and (c) there is no straightforward relationship between flexible word order and whether focus and givenness are prosodically marked, contrary to earlier claims, because both Czech and Polish, with their relatively flexible word order, are more similar to English than Romance languages.
[Cr-Ti-Al-N complex coating on titanium to strengthen Ti/porcelain bonding].
Zhang, Hui; Guo, Tian-wen; Li, Jun-ming; Pan, Jing-guang; Dang, Yong-gang; Tong, Yu
2006-02-01
To study the feasibility of magnetron sputtering Cr-Ti-Al-N complex coating as an interlayer on titanium to enhance the titanium-ceramic binding strength. With a three-point bending test according to ISO 9693, the binding strength of Duceratin (Degussa) to titanium substrate prepared with 4 different surface treatments (polishing, polishing and megnetron sputtering Cr, Ti, Al, and N complex coating, sandblasting, sandblasting and coating) was evaluated. Ti/porcelain interface and fractured Ti surface were examined using scanning electron microscopy with energy-dispersive spectrometry (EDS). The binding strength of polished and coated titanium/Duceratin was significantly higher than polished titanium group (P<0.05). The binding strength of sandblasted and coated titanium/Duceratin did not differ significantly from that of sandblasted titanium group (P>0.05), and the strength in the two sandblasted titanium groups was significantly higher than that in polished and coated titanium group (P<0.05). Megnetron sputtering Cr-Ti-Al-N complex on polished titanium can increase the titanium/porcelain binding strength. Megnetron sputtering coating is a promising Ti/porcelain interlayer.
Drago, Lorenzo; Del Fabbro, Massimo; Bortolin, Monica; Vassena, Christian; De Vecchi, Elena; Taschieri, Silvio
2014-11-01
Biofilm removal plays a central role in the prevention of periodontal and peri-implant diseases associated with microbial infections. Plaque debridement may be accomplished by air polishing using abrasive powders. In this study, a new formulation consisting of erythritol and chlorhexidine is compared with the standard glycine powder used in air-polishing devices. Their in vitro antimicrobial and antibiofilm effects on Staphylococcus aureus, Bacteroides fragilis, and Candida albicans are investigated. Biofilm was allowed to grow on sandblasted titanium disks and air polished with glycine or erythritol-chlorhexidine powders. A semiquantitative analysis of biofilm by spectrophotometric assay was performed. A qualitative analysis was also carried out by confocal laser scanning microscopy. Minimum inhibitory concentrations and minimum microbicidal concentrations were evaluated, together with the microbial recovery from the residual biofilm after air-polishing treatment. The combination of erythritol and chlorhexidine displayed stronger antimicrobial and antibiofilm activity than glycine against all microbial strains tested. Air polishing with erythritol-chlorhexidine seems to be a viable alternative to the traditional glycine treatment for biofilm removal.
Chen, Nan-Kuang; Lee, Cheng-Ling; Chi, Sien
2007-12-24
We demonstrate tunable highly wavelength-selective filter based on a 2 x 2 asymmetric side-polished fiber coupler with dispersive interlayer in one of the coupling arms. The asymmetric fiber coupler is made of two side-polished fibers using identical single-mode fibers and one of the polished fibers is further chemically etched at the central evanescent coupling region to gain closer to the core. An optical liquid with different dispersion characteristics than that of silica fiber is used to fill up the etched hollow and therefore the propagation constant for the polished fiber with dispersive liquid becomes more dispersive and crosses with that of another untreated polished fiber. The location of the cross point and the cross angle between two propagation constant curves determine the coupling wavelength and coupling bandwidth as well as channel wavelength separation, respectively. The coupling wavelength can be tuned at least wider than 84 nm (1.326-1.410 microm) under index variation of 0.004 and with coupling ratios of higher than 30 dB.
The role of food in the Polish migrant adjustment journey.
Brown, Lorraine; Paszkiewicz, Irena
2017-02-01
In 2015, there were 916,000 Poles living in the UK, making them the largest group of non-UK nationals at 16.5 percent of the population. Though increasingly research has focused on the consequences of this migration for both migrants themselves and the receiving country, little research has looked at food habits. This paper will explore the role of food in the Polish migrant adjustment journey. A qualitative approach was adopted, involving semi-structured interviews with nine Polish migrants. In this study, Polish migrants described the move to a new culture as a time of stress and loneliness. Due to a lack of money, they were forced to eat local food, which exacerbated their unease, as they found it to be tasteless and unhealthy. As soon as their financial situation improved, they reverted to a Polish diet, relying on ingredients brought from home, from London, or more recently, purchased from local Polish shops. This gave them comfort, and all participants acknowledged the vital role of food in their adjustment to life in a new culture. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gyorke, D.F.; Butcher, T.A.
1995-12-31
To implement the Krakow Clean Fossil Fuels and Energy Efficiency Program, eight U.S. firms were selected by the U.S. Department of Energy to market their technologies to reduce pollution from low emission sources in Krakow. The eight U.S. firms were selected by a competitive solicitation that required the proposing firms to themselves provide funding to match or exceed the funding provided by the Program. These U.S. firms and their Polish partner companies have begun sales and cooperative work efforts in Krakow, and some have already made initial equipment installations with measurable performance improvements. Following their efforts as part of themore » Program, these U.S.-Polish joint ventures will market their technologies and achieve the associated environmental benefits elsewhere in Poland and Eastern and Central Europe. As part of the Krakow Program a spreadsheet model was developed to compare technological options for supplying heat to the city by calculation and comparing the heating costs and associated emissions reduction for each option. Comparison of options is made on the basis of the user cost-per-metric ton of equivalent emissions reduction. For all options considered in the Krakow Program, this cost parameter has ranged from -$1469 (best) to $2650 (worst). The costs for technologies associated with the eight projects in the Krakow Program are at the lower end of this range placing these technologies among the most cost effective solutions to the pollution problems from the low emission sources.« less
Tooth polishing: The current status
Sawai, Madhuri Alankar; Bhardwaj, Ashu; Jafri, Zeba; Sultan, Nishat; Daing, Anika
2015-01-01
Healthy teeth and gums make a person feel confident and fit. As people go about their daily routines and with different eating and drinking habits, the tooth enamel turns yellowish or gets stained. Polishing traditionally has been associated with the prophylaxis procedure in most dental practices, which patients know and expect. However, with overzealous use of polishing procedure, there is wearing of the superficial tooth structure. This would lead to more accumulation of local deposits. Also, it takes a long time for the formation of the fluoride-rich layer of the tooth again. Hence, now-a-days, polishing is not advised as a part of routine oral prophylaxis procedure but is done selectively based on the patients’ need. The article here, gives an insight on the different aspects of the polishing process along with the different methods and agents used for the same. PMID:26392683
Detection of paint polishing defects
NASA Astrophysics Data System (ADS)
Rebeggiani, S.; Wagner, M.; Mazal, J.; Rosén, B.-G.; Dahlén, M.
2018-06-01
Surface finish plays a major role on perceived product quality, and is the first thing a potential buyer sees. Today end-of-line repairs of the body of cars and trucks are inevitably to secure required surface quality. Defects that occur in the paint shop, like dust particles, are eliminated by manual sanding/polishing which lead to other types of defects when the last polishing step is not performed correctly or not fully completed. One of those defects is known as ‘polishing roses’ or holograms, which are incredibly hard to detect in artificial light but are clearly visible in sunlight. This paper will present the first tests with a measurement set-up newly developed to measure and analyse polishing roses. The results showed good correlations to human visual evaluations where repaired panels were estimated based on the defects’ intensity, severity and viewing angle.
Ereifej, N S; Oweis, Y G; Eliades, G
2013-01-01
The aim of this study was to compare surface roughness and gloss of resin composites polished using different polishing systems. Five resin composites were investigated: Filtek Silorane (FS), IPS Empress Direct (IP), Clearfil Majesty Posterior (CM), Premise (PM), and Estelite Sigma (ES). Twenty-five disk specimens were prepared from each material, divided into five groups, each polished with one of the following methods: Opti1Step (OS), OptiDisc (OD), Kenda CGI (KD), Pogo (PG), or metallurgical polishing (ML). Gloss and roughness parameters (Sa, Sz, Sq, and St) were evaluated by 60°-angle glossimetry and white-light interferometric profilometry. Two-way analysis of variance was used to detect differences in different materials and polishing techniques. Regression and correlation analyses were performed to examine correlations between roughness and gloss. Significant differences in roughness parameters and gloss were found according to the material, type of polishing, and material/polishing technique (p< 0.05). The highest roughness was recorded when KD was used (Sa: 581.8 [62.1] for FS/KD, Sq: 748.7 [55.6] for FS/KD, Sz: 17.7 [2.7] for CM/KD, and St: 24.6 [6.8] for FS/KD), while the lowest was recorded after ML (Sa: 133.6 [68.9] for PM/ML, Sq: 256.5 [53.5] for ES/ML, Sz: 4.0 [1.3] for ES/ML, and St: 7.1 [0.7] for ES/ML). The highest gloss was recorded for PM/ML (88.4 [2.3]) and lowest for FS/KD (30.3 [5.7]). All roughness parameters were significantly correlated with gloss (r= 0.871, 0.846, 0.713, and 0.707 for Sa, Sq, Sz, St, and gloss, respectively). It was concluded that the polishing procedure and the type of composite can have significant impacts on surface roughness and gloss of resin composites.
An evaluation of wear when enamel is opposed by various ceramic materials and gold.
Elmaria, Asmaa; Goldstein, Gary; Vijayaraghavan, Therizhandur; Legeros, Raquel Z; Hittelman, Eugene L
2006-11-01
Ceramic restorations have been known to cause wear of opposing enamel. The purpose of this study was to evaluate enamel wear caused by 3 ceramic substrates in the glazed and polished conditions. Sixty ceramic discs (10 x 2 mm)-20 each of Finesse, All-Ceram, and IPS-Empress-were prepared and glazed. Each group of 20 was divided into 2 groups of 10. The surfaces of one group were ground and polished using a porcelain polishing kit (Dialite). The remaining 10 were left as glazed. Ten specimens of a type III gold alloy were cast into rectangular shapes of 10 x 12 x 2 mm and polished. Seventy human cusps were prepared from sound, caries-free, extracted teeth and abraded against the substrates in a wear machine for a total of 10,000 cycles. The cusp height loss was traced before and after the wear test using a profile projector. Mean surface roughness (R(a)) values for the substrates were also recorded with a profilometer before testing. Differences in R(a) were evaluated using 1- and 2-way ANOVA and the Scheffe post hoc test (alpha = .05). One-way ANOVA indicated that enamel height loss was significantly different by material (P < .001) and surface condition (glazed and polished or glazed; P < .05). Gold, polished Finesse, and polished All-Ceram were the least abrasive, whereas glazed IPS-Empress was the most abrasive. There was no significant interaction effect between substrate type and surface condition. Significant differences were found when R(a) of the substrate condition was compared with enamel wear (P < .01). Gold, polished Finesse, and polished All-Ceram caused the least enamel wear, whereas IPS-Empress caused the most wear. Cast gold was significantly different than glazed IPS-Empress (P < .05), whereas other groups overlapped. There was significant correlation between R(a) and enamel wear (P < .01).
Measuring Skew in Average Surface Roughness as a Function of Surface Preparation
NASA Technical Reports Server (NTRS)
Stahl, Mark
2015-01-01
Characterizing surface roughness is important for predicting optical performance. Better measurement of surface roughness reduces polishing time, saves money and allows the science requirements to be better defined. This study characterized statistics of average surface roughness as a function of polishing time. Average surface roughness was measured at 81 locations using a Zygo white light interferometer at regular intervals during the polishing process. Each data set was fit to a normal and Largest Extreme Value (LEV) distribution; then tested for goodness of fit. We show that the skew in the average data changes as a function of polishing time.
Method for producing smooth inner surfaces
Cooper, Charles A.
2016-05-17
The invention provides a method for preparing superconducting cavities, the method comprising causing polishing media to tumble by centrifugal barrel polishing within the cavities for a time sufficient to attain a surface smoothness of less than 15 nm root mean square roughness over approximately a 1 mm.sup.2 scan area. The method also provides for a method for preparing superconducting cavities, the method comprising causing polishing media bound to a carrier to tumble within the cavities. The method also provides for a method for preparing superconducting cavities, the method comprising causing polishing media in a slurry to tumble within the cavities.
Flury, Simon; Diebold, Elisabeth; Peutzfeldt, Anne; Lussi, Adrian
2017-06-01
Because of the different composition of resin-ceramic computer-aided design and computer-aided manufacturing (CAD-CAM) materials, their polishability and their micromechanical properties vary. Moreover, depending on the composition of the materials, their surface roughness and micromechanical properties are likely to change with time. The purpose of this in vitro study was to investigate the effect of artificial toothbrushing and water storage on the surface roughness (Ra and Rz) and the micromechanical properties, surface hardness (Vickers [VHN]) and indentation modulus (E IT ), of 5 different tooth-colored CAD-CAM materials when polished with 2 different polishing systems. Specimens (n=40 per material) were cut from a composite resin (Paradigm MZ100; 3M ESPE), a feldspathic ceramic (Vitablocs Mark II; Vita Zahnfabrik), a resin nanoceramic (Lava Ultimate; 3M ESPE), a hybrid dental ceramic (Vita Enamic; Vita Zahnfabrik), and a nanocomposite resin (Ambarino High-Class; Creamed). All specimens were roughened in a standardized manner and polished either with Sof-Lex XT discs or the Vita Polishing Set Clinical. Surface roughness, VHN, and E IT were measured after polishing and after storage for 6 months (tap water, 37°C) with periodic, artificial toothbrushing. The surface roughness, VHN, and E IT results were analyzed with a nonparametric ANOVA followed by Kruskal-Wallis and exact Wilcoxon rank sum tests (α=.05). Irrespective of polishing system and of artificial toothbrushing and storage, Lava Ultimate generally showed the lowest surface roughness and Vitablocs Mark II the highest. As regards micromechanical properties, the following ranking of the CAD-CAM materials was found (from highest VHN/E IT to lowest VHN/E IT ): Vitablocs Mark II > Vita Enamic > Paradigm MZ100 > Lava Ultimate > Ambarino High-Class. Irrespective of material and of artificial toothbrushing and storage, polishing with Sof-Lex XT discs resulted in lower surface roughness than the Vita Polishing Set Clinical (P≤.016). However, the polishing system generally had no influence on the micromechanical properties (P>.05). The effect of artificial toothbrushing and storage on surface roughness depended on the material and the polishing system: Ambarino High-Class was most sensitive to storage, Lava Ultimate and Vita Enamic were least sensitive. Artificial toothbrushing and storage generally resulted in a decrease in VHN and E IT for Paradigm MZ100, Lava Ultimate, and Ambarino High-Class but not for Vita Enamic and Vitablocs Mark II. Tooth-colored CAD-CAM materials with lower VHN and E IT generally showed better polishability. However, these materials were more prone to degradation by artificial toothbrushing and water storage than materials with higher VHN and E IT . Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Design and Test Plan for an Integrated Iodine Scrubber and Polishing Bed System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jubin, Robert Thomas
The capture and subsequent immobilization of four regulated volatile radionuclides ( 3H, 14C, 85Kr, and 129I) and relevant semivolatile species from the off-gas streams of a used nuclear fuel (UNF) reprocessing facility has been a topic of significant research interest on the part of the US Department of Energy and other international organizations. Significant research and development has been conducted over the past decade. In 2016 an initial engineering evaluation and design of the off-gas abatement systems required for a hypothetical 1000 t/yr UNF reprocessing facility treating 5 yr–cooled, 60 GWd/tIHM UNF was completed. One of the key findings ofmore » that report was that the consumption rate of silver-based iodine sorbents in the dissolver off-gas primary iodine capture bed is very high and may warrant the evaluation of alternative methods to capture the bulk of the iodine that could significantly reduce the associated frequent remote handing of the iodine filter beds. This report is intended to describe the design of an experimental system that can be used to examine the use of aqueous scrubbing to remove the bulk of the iodine from the dissolver off-gas stream prior to a silver-based solid sorbent that would be used to provide the final iodine capture or polishing step. This report also provides a description of the initial series of tests that are proposed for this system.« less
Cattani-Lorente, M; Scherrer, S S; Durual, S; Sanon, C; Douillard, T; Gremillard, L; Chevalier, J; Wiskott, A
2014-10-01
Implant surface modifications are intended to enhance bone integration. The objective of this study was to assess the effect of different surface treatments on the resistance to hydrothermal degradation, hardness and elastic modulus of a 3Y-TZP ceramic used for dental implants. Samples grouped according to their surface morphologies (AS, as-sintered; C, coated; P, dry-polished; R, roughened; PA, polished and annealed; RA, roughened and annealed) were subjected to accelerated hydrothermal degradation (LTD) by exposure to water steam (134°C, 2bars) for 100h. The t-m phase transformation was quantified by grazing incidence X-ray diffraction (GIXDR) and by combined focused ion beam and scanning electron microscopy (FIB-SEM). Elastic modulus and hardness before- and after prolonged aging (100h) were assessed by nanoindentation. AS and C specimens presented a better resistance to hydrothermal degradation than P and R samples. After prolonged aging, the depth of the monoclinic transformed layer ranged from 11μm to 14μm. Hydrothermal degradation led to a significant decrease of elastic modulus and hardness. Surface treatments affected the resistance to hydrothermal degradation of the 3Y-TZP ceramic. Dry mechanical surface modifications should be avoided since a high t-m transformation rate associated to the initial monoclinic content was observed. Annealing was useful to reverse the initial t-m transformation, but did not improve the resistance to hydrothermal degradation. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ledeuil, J. B.; Uhart, A.; Soulé, S.; Allouche, J.; Dupin, J. C.; Martinez, H.
2014-09-01
This work has examined the elemental distribution and local morphology at the nanoscale of core@shell Ag/Au@SiO2 particles. The characterization of such complex metal/insulator materials becomes more efficient when using an initial cross-section method of preparation of the core@shell nanoparticles (ion milling cross polisher). The originality of this route of preparation allows one to obtain undamaged, well-defined and planar layers of cross-cut nano-objects. Once combined with high-resolution techniques of characterization (XPS, Auger and SEM), the process appears as a powerful way to minimize charging effects and enhance the outcoming electron signal (potentially affected by the topography of the material) during analysis. SEM experiments have unambiguously revealed the hollow-morphology of the metal core, while Auger spectroscopy observations showed chemical heterogeneity within the particles (as silver and gold are randomly found in the core ring). To our knowledge, this is the first time that Auger nano probe spectroscopy has been used and successfully optimized for the study of some complex metal/inorganic interfaces at such a high degree of resolution (~12 nm). Complementarily, XPS Au 4f and Ag 3d peaks were finally detected attesting the possibility of access to the whole chemistry of such nanostructured assemblies.This work has examined the elemental distribution and local morphology at the nanoscale of core@shell Ag/Au@SiO2 particles. The characterization of such complex metal/insulator materials becomes more efficient when using an initial cross-section method of preparation of the core@shell nanoparticles (ion milling cross polisher). The originality of this route of preparation allows one to obtain undamaged, well-defined and planar layers of cross-cut nano-objects. Once combined with high-resolution techniques of characterization (XPS, Auger and SEM), the process appears as a powerful way to minimize charging effects and enhance the outcoming electron signal (potentially affected by the topography of the material) during analysis. SEM experiments have unambiguously revealed the hollow-morphology of the metal core, while Auger spectroscopy observations showed chemical heterogeneity within the particles (as silver and gold are randomly found in the core ring). To our knowledge, this is the first time that Auger nano probe spectroscopy has been used and successfully optimized for the study of some complex metal/inorganic interfaces at such a high degree of resolution (~12 nm). Complementarily, XPS Au 4f and Ag 3d peaks were finally detected attesting the possibility of access to the whole chemistry of such nanostructured assemblies. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr03211j
Hunt, N P; Cunningham, S J; Golden, C G; Sheriff, M
1999-10-01
The purpose of this study was to investigate the effect of surface roughness on the relative corrosion rates of wires of four alloys-stainless steel, nickel titanium, cobalt chromium, and beta titanium. Batches of wire were divided into two groups. Wires in one group were industrially polished to provide a uniform surface finish; wires in the other group were left for comparison "as received." Wire diameter, hardness, and relative corrosion rates were compared within groups before and after polishing. Comparisons were also made across the four groups of alloys. The samples of as-received wires showed variations in surface finish, with beta titanium having the roughest appearance and cobalt chromium the smoothest. Nickel titanium and stainless steel surfaces were similar. Polishing provided a more uniform finish, but significantly reduced the diameter of the wires. Microhardness testing of wire surfaces of each alloy indicated that no significant work-hardening occurred as a result of polishing. The relative corrosion rates (expressed in terms of corrosion current density) in a 0.9% sodium chloride solution were estimated using the electrochemical technique of polarization resistance. Nickel titanium wires exhibited the greatest corrosion current density in the as-received state. Polishing significantly reduced the corrosion rate of nickel titanium, such that comparison between the four alloys in the polished state revealed no significant difference in their relative corrosion rate/corrosion current density.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menapace, J A; Ehrmann, P R; Bickel, R C
2009-11-05
Over the past year we have been working on specialized MR fluids for polishing KDP crystals. KDP is an extremely difficult material to conventionally polish due to its water solubility, low hardness, and temperature sensitivity. Today, KDP crystals are finished using single-point diamond turning (SPDT) tools and nonaqueous lubricants/coolants. KDP optics fabricated using SPDT, however, are limited to surface corrections due to tool/method characteristics with surface quality driven by microroughness from machine pitch, speed, force, and diamond tool character. MRF polishing offers a means to circumvent many of these issues since it is deterministic which makes the technique practical formore » surface and transmitted wavefront correction, is low force, and is temperature independent. What is lacking is a usable nonaqueous MR fluid that is chemically and physically compatible with KDP which can be used for polishing and subsequently cleaned from the optical surface. In this study, we will present the fluid parameters important in the design and development of nonaqueous MR fluid formulations capable of polishing KDP and how these parameters affect MRF polishing. We will also discuss requirements peculiar to successful KDP polishing and how they affect optical figure/finish and laser damage performance at 1064 nm and 532 nm.« less
Global Citizenship Education in School Curricula. A Polish Perspective
ERIC Educational Resources Information Center
Leek, Joanna
2016-01-01
The purpose of this study is to present global citizenship education from a Polish perspective. Analyzing the issue, the first part of this paper presents the development of citizenship education, followed by the current status of global citizenship education in Polish schools. In the second part of the study I draw attention to national curricula…
The Ranking of Global Environmental Issues and Problems by Polish Secondary Students and Teachers.
ERIC Educational Resources Information Center
Robinson, Michael; Trojok, Tomasz; Norwisz, Jan
1997-01-01
Identifies and discusses Polish student and teacher priorities of Bybee's 12 environmental problems in two cities in Katowice Province. Provides pertinent background on the Polish educational system. Presents reasons why the current science teaching model must be changed if the science curriculum is to provide more understanding of Bybee's 12…
Holding fixture for metallographic mount polishing
Barth, Clyde H.; Cramer, Charles E.
1997-01-01
A fixture for holding mounted specimens for polishing, having an arm; a body attached to one end of the arm, the body having at least one flange having an opening to accommodate a mounted specimen; and a means applying pressure against the outer surface of the mounted specimen to hold the specimen in contact with the polishing surface.
ERIC Educational Resources Information Center
Clark, Lynn; Schleef, Erik
2010-01-01
In order to achieve full native-like competence in a second language, speakers must also acquire sociolinguistic awareness in that language. This paper reports the results of a study investigating the acquisition of sociolinguistic awareness among immigrant Polish adolescents learning English in the UK. This paper asks whether Polish-born…
Reading Function and Content Words in Subtitled Videos
ERIC Educational Resources Information Center
Krejtz, Izabela; Szarkowska, Agnieszka; Loginska, Maria
2016-01-01
In this study, we examined how function and content words are read in intra- and interlingual subtitles. We monitored eye movements of a group of 39 deaf, 27 hard of hearing, and 56 hearing Polish participants while they viewed English and Polish videos with Polish subtitles. We found that function words and short content words received less…