Remediation of Chlorinated Solvent Plumes Using In-Situ Air Sparging—A 2-D Laboratory Study
Adams, Jeffrey A.; Reddy, Krishna R.; Tekola, Lue
2011-01-01
In-situ air sparging has evolved as an innovative technique for soil and groundwater remediation impacted with volatile organic compounds (VOCs), including chlorinated solvents. These may exist as non-aqueous phase liquid (NAPL) or dissolved in groundwater. This study assessed: (1) how air injection rate affects the mass removal of dissolved phase contamination, (2) the effect of induced groundwater flow on mass removal and air distribution during air injection, and (3) the effect of initial contaminant concentration on mass removal. Dissolved-phase chlorinated solvents can be effectively removed through the use of air sparging; however, rapid initial rates of contaminant removal are followed by a protracted period of lower removal rates, or a tailing effect. As the air flow rate increases, the rate of contaminant removal also increases, especially during the initial stages of air injection. Increased air injection rates will increase the density of air channel formation, resulting in a larger interfacial mass transfer area through which the dissolved contaminant can partition into the vapor phase. In cases of groundwater flow, increased rates of air injection lessened observed downward contaminant migration effect. The air channel network and increased air saturation reduced relative hydraulic conductivity, resulting in reduced groundwater flow and subsequent downgradient contaminant migration. Finally, when a higher initial TCE concentration was present, a slightly higher mass removal rate was observed due to higher volatilization-induced concentration gradients and subsequent diffusive flux. Once concentrations are reduced, a similar tailing effect occurs. PMID:21776228
Remediation of chlorinated solvent plumes using in-situ air sparging--a 2-D laboratory study.
Adams, Jeffrey A; Reddy, Krishna R; Tekola, Lue
2011-06-01
In-situ air sparging has evolved as an innovative technique for soil and groundwater remediation impacted with volatile organic compounds (VOCs), including chlorinated solvents. These may exist as non-aqueous phase liquid (NAPL) or dissolved in groundwater. This study assessed: (1) how air injection rate affects the mass removal of dissolved phase contamination, (2) the effect of induced groundwater flow on mass removal and air distribution during air injection, and (3) the effect of initial contaminant concentration on mass removal. Dissolved-phase chlorinated solvents can be effectively removed through the use of air sparging; however, rapid initial rates of contaminant removal are followed by a protracted period of lower removal rates, or a tailing effect. As the air flow rate increases, the rate of contaminant removal also increases, especially during the initial stages of air injection. Increased air injection rates will increase the density of air channel formation, resulting in a larger interfacial mass transfer area through which the dissolved contaminant can partition into the vapor phase. In cases of groundwater flow, increased rates of air injection lessened observed downward contaminant migration effect. The air channel network and increased air saturation reduced relative hydraulic conductivity, resulting in reduced groundwater flow and subsequent downgradient contaminant migration. Finally, when a higher initial TCE concentration was present, a slightly higher mass removal rate was observed due to higher volatilization-induced concentration gradients and subsequent diffusive flux. Once concentrations are reduced, a similar tailing effect occurs.
Effect of moisture content on fed batch composting reactor of vegetable and fruit wastes.
Jolanun, B; Tripetchkul, S; Chiemchaisri, C; Chaiprasert, P; Towprayoon, S
2005-03-01
Vegetable and fruit wastes mixed with sawdust were composted in a laboratory scale reactor by controlling the waste feeding rate at 21 kg m(-3) day(-1) and aeration rate at 10.6 l m(-3) min(-1). The effects of initial moisture content on organic matter degradation and process performance of fed batch composting were investigated. The absolute amount of removal, removal percentage, and removal rate of dry mass obtained were substantially different among the initial moisture contents. The rapid rise of moisture content and the lowest absolute amount of removal observed were achieved in the 50% condition. The initial moisture content yielding the largest absolute amount of removal in both feeding and curing stage was 30% whereas the removal percentage and rate constant of waste decomposition were highest in the 50% condition. Examined by traditional soil physics method, the moisture content at 50-55% was suitable for satisfying the degree of free air space (65-70%) of compost during the fed batch composting. Most degradable organic matter was mainly consumed in the feeding stage as indicated by a higher removal rate of dry mass in all cases. It is recommended that the initial moisture content of 30% and mode of aeration and agitation should be adopted for achieving practical fed batch composting of vegetable and fruit wastes. The study also demonstrated that the composting kinetics of vegetable and fruit wastes mixed with sawdust can be described by a first order model.
Simultaneous effect of initial moisture content and airflow rate on biodrying of sewage sludge.
Huiliñir, Cesar; Villegas, Manuel
2015-10-01
The simultaneous effect of initial moisture content (initial Mc) and air-flow rate (AFR) on biodrying performance was evaluated. For the study, a 3(2) factorial design, whose factors were AFR (1, 2 and 3 L/min kg(TS)) and initial Mc (59, 68 and 78% w.b.), was used. Using energy and water mass balance the main routes of water removal, energy use and efficiencies were determined. The results show that initial Mc has a stronger effect on the biodrying than the AFR, affecting the air outlet temperature and improving the water removal, with higher maximum temperatures obtained around 68% and the lowest maximum matrix temperature obtained at initial Mc = 78%.Through the water mass balance it was found that the main mechanism for water removal was the aeration, with higher water removal at intermediate initial Mc (68%) and high AFR (3 L/min kg(TS)). The energy balance indicated that bioreaction is the main energy source for water evaporation, with higher energy produced at intermediate initial Mc (68%). Finally, it was found that low values of initial Mc (59%) improve biodrying efficiency. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Yang, Lan; Wei, Jie; Zhang, Yumei; Wang, Jianli; Wang, Dongtian
2014-06-01
Acid coagulant-recovered drinking waterworks sludge residual (DWSR) is a waste product from drinking waterworks sludge (DWS) treatment with acid for coagulant recovery. In this study, we evaluated DWSR as a potential phosphorus (P) removing material in wastewater treatment by conducting a series of batch and semi-continuous tests. Batch tests were carried out to study the effects of pH, initial concentration, and sludge dose on P removal. Batch test results showed that the P removal efficiency of DWSR was highly dependent on pH. Calcinated DWSR (C-DWSR) performed better in P removal than DWSR due to its higher pH. At an optimum initial pH value of 5-6 and a sludge dose of 10 g/L, the P removal rates of DWSR and DWS decreased from 99% and 93% to 84% and 14%, respectively, and the specific P uptake of DWSR and DWS increased from 0.19 and 0.19 mg P/g to 33.60 and 5.72 mg P/g, respectively, when the initial concentration was increased from 2 to 400 mg/L. The effective minimum sludge doses of DWSR and DWS were 0.5 g/L and 10 g/L, respectively, when the P removal rates of 90% were obtained at an initial concentration of 10 mg/L. Results from semi-continuous test indicated that P removal rates over 99% were quickly achieved for both synthetic and actual wastewater (lake water and domestic sewage). These rates could be maintained over a certain time under a certain operational conditions including sludge dose, feed flow, and initial concentration. The physicochemical properties analysis results showed that the contents of aluminum (Al) and iron (Fe) in DWSR were reduced by 50% and 70%, respectively, compared with DWS. The insoluble Al and Fe hydroxide in DWS converted into soluble Al and Fe in DWSR. Metal leaching test results revealed that little soluble Al and Fe remained in effluent when DWSR was used for P removal. We deduced that chemical precipitation might be the major action for P removal by DWSR and that adsorption played only a marginal role.
Fu, Wantao; Wu, Yichun; Sun, Liming; Zhang, Wei
2007-08-15
The aim of this study is to investigate the potential of using marine sponge Hymeniacidon perleve to remove total organic carbon (TOC) in integrated aquaculture ecosystems. In sterilized natural seawater (SNSW) with different concentrations of TOC, H. perleve removed approximately 44-61% TOC during 24 h, with retention rates of ca. 0.19-1.06 mg/h .g-fresh sponge, however no particulate selectivity was observed. The highest initial TOC concentration, in which about 2.7 g fresh sponges could remove TOC effectively in 0.5-L SNSW, is 214.3-256.9 mg/L. The highest capacity of TOC removal and clearance rate (CR) by H. perleve is ca. 25.50 mg-TOC/g-fresh sponge and 7.64 mL/h . g-fresh sponge within 24 h, respectively. Until reaching the highest TOC removal capacity, the TOC removal capacity and clearance rate of H. perleve increased with initial TOC concentration, and dropped dramatically thereafter. After reaching the highest removal capacity, H. perleve could only remove relatively lower TOC concentration in seawater in subsequent run. The TOC removal kinetics in SNSW by H. perleve fitted very well with a S-shaped curve and a Logistic model equation (R(2) = 0.999). In different volumes of SNSW with a fixed initial TOC concentration, the weight/volume ratio of sponge biomass and SFNSW was optimized at 1.46 g-fresh sponge/1-L SNSW to achieve the maximum TOC removal. When co-cultured with marine fish Fugu rubripes for 15 days, H. perleve removed TOC excreted by F. rubripes with similar retention rates of ca. 0.15 mg/h . g-fresh sponge, and the sponge biomass increased by 22.8%. (c) 2007 Wiley Periodicals, Inc.
Removal of dimethyl phthalate from water by ozone microbubbles.
Jabesa, Abdisa; Ghosh, Pallab
2017-08-01
This work investigates the removal of dimethyl phthalate (DMP) from water using ozone microbubbles in a pilot plant of 20 dm 3 capacity. Experiments were performed under various reaction conditions to examine the effects of the initial concentration of DMP, pH of the medium, ozone generation rate, and the role of H 2 O 2 on the removal of DMP. The DMP present in water was effectively removed by the ozone microbubbles. The removal was effective in neutral and alkaline media. Increase in the initial concentration of the target pollutant negatively affected its removal efficiency. The removal efficiency dramatically increased from 1% to 99% when the ozone generation rate was increased from 0.28 to 1.94 mg s -1 at pH 7. The total organic carbon measurements revealed that a complete mineralization of DMP was achieved within 1.8 ks at the high ozone feed rate. The use of t-butyl alcohol as the hydroxyl radical scavenger confirmed that the reaction between the target organic compound and ·OH radical dominated over its direct reaction with ozone. The reaction between DMP and ozone followed an overall second-order kinetics. The volumetric mass transfer coefficient of ozone in the reacting system and the enhancement factor increased with increasing initial concentration of DMP. Very low values of Hatta number were obtained at all initial concentrations of DMP and pH, which show that the mass transfer resistance was small.
Cadmium removal from wastewater by sponge iron sphere prepared by charcoal direct reduction.
Li, Junguo; Li, Jun; Li, Yungang
2009-01-01
Sponge iron sphere (SIS), made of concentrated iron powder and possessed high activity and intension, was prepared through the process of palletizing, roasting and direct reduction by charcoal. The sponge iron sphere could remove most of Cd(2+) from wastewater. The results showed the Cd(2+) removal followed the first order reaction. Initial pH value played an important role in Cd(2+) removal. With original initial pH, Cd(2+) removal decreased to the minimum and then increased slightly with the rising of original concentration. The removal rate constant was -0.1263 and -0.0711 h(-1), respectively, under the Cd(2+) concentration of 50 and 200 mg/L. When the initial pH was adjusted to 3.0, the removal rate constant could increase to -9.896 and -4.351 h(-1), respectively. The removal percentage almost reached to 100% when Cd(2+) concentration was below 100 mg/L. While Cd(2+) concentration was above 100 mg/L, Cd(2+) removal percentage decreased slightly. In dynamic experiments, the column filled with sponge iron sphere exhibited favorable permeability. There was no sphere pulverization and conglutination between spheres. In contrast to the static state experiments, the Cd(2+) removal percentage in dynamic state experiment was lower, and the removal Cd(2+) quantity was 1.749 mg/g.
Rapid removal of nitrobenzene in a three-phase ozone loaded system with gas-liquid-liquid
Li, Shiyin; Zhu, Jiangpeng; Wang, Guoxiang; Ni, Lixiao; Zhang, Yong; Green, Christopher T.
2015-01-01
This study explores the removal rate of nitrobenzene (NB) using a new gas-liquid-liquid (G-L-L) three-phase ozone loaded system consisting of a gaseous ozone, an aqueous solvent phase, and a fluorinated solvent phase (perfluorodecalin, or FDC). The removal rate of NB was quantified in relation to six factors including 1) initial pH, 2) initial NB dosage, 3) gaseous ozone dosage, 4) free radical scavenger, 5) FDC pre-aerated gaseous ozone, and 6) reuse of FDC. The NB removal rate is positively affected by the first three factors. Compared with the conventional gas-liquid (water) (G-L) two-phase ozonation system, the free radical scavenger (tertiary butyl alcohol) has much less influence on the removal rate of NB in the G-L-L system. The FDC loaded ozone acts as an ozone reservoir and serves as the main reactive phase in the G-L-L three-phase system. The reuse of FDC has little influence on the removal rate of NB. These experimental results suggest that the oxidation efficiency of ozonation in the G-L-L three-phase system is better than that in the conventional G-L two-phase system.
Chen, Shan-Jia; Chen, Xiu-Rong; Yan, Long; Zhao, Jian-Guo; Zhang, Fei; Jiang, Zi-Jian
2014-04-01
The effects of different concentrations of bisphenol A (BPA) on Chlorella vulgaris and removal capacity of BPA by Chlorella vulgaris were investigated. Results showed that a low concentration (0-20 mg x L(-1)) of BPA promoted the growth of Chlorella vulgaris, whereas a relative high concentration (20-50 mg x L(-1)) of BPA inhibited the growth of Chlorella vulgaris, and the inhibition effect was positively correlated with the concentration of BPA. Likewise, a high dose of initial BPA (> 20 mg x L(-1)) led to a decline in the content of chlorephyll a. Chlorella vulgaris had BPA removal capacity when initial BPA concentration ranged from 2 mg x L(-1) to 50 mg x L(-1). There was positive correlation between the removal rate of BPA per cell and initial BPA concentration. The removal rate of BPA was the highest when initial BPA was 50 mg x L(-1), which appeared between lag phase and logarithmic phase.
Shu, Xiao-ming; Xu, Can-can; Liu, Rui; Zhao, Yuan; Chen, Lü-jun
2016-02-15
Nanoscale Ni/Fe was applied to biologically treated effluent of chemical dyestuff wastewater. The removal rates of absorbable organic halogens (AOX) and chroma were investigated at different Ni loadings (0-5%), initial wastewater pH (4.1-10.0), Ni/Fe dosage (1-5 g x L(-1)) and reaction time (0.5-96 h). The results showed that the removal rates of AOX and chroma firstly increased and then decreased with the increase of the Ni loading, while continuously increased with the decrease of the initial wastewater pH and the increase of Ni/Fe dosage. The optimal condition was Ni loading of 1%, initial wastewater pH of 4.1 and Ni/Fe dosage of 3 g x L(-1), under which 29.2% of AOX and 79.6% of chroma were removed after 24 h reaction, and 50.6% of AOX and 80.7% of chroma were removed after 96 h reaction. GC-MS analysis revealed that toxicants such as chlorinated anilines, p-nitroaniline, 4-methoxy-2-nitroaniline and halogenated hydrocarbons were efficiently removed.
Denitrification using a monopolar electrocoagulation/flotation (ECF) process.
Emamjomeh, Mohammad M; Sivakumar, Muttucumaru
2009-01-01
Nitrate levels are limited due to health concerns in potable water. Nitrate is a common contaminant in water supplies, and especially prevalent in surface water supplies and shallow wells. Nitrate is a stable and highly soluble ion with low potential for precipitation or adsorption. These properties make it difficult to remove using conventional water treatment methods. A laboratory batch electrocoagulation/flotation (ECF) reactor was designed to investigate the effects of different parameters such as electrolysis time, electrolyte pH, initial nitrate concentration, and current rate on the nitrate removal efficiency. The optimum nitrate removal was observed at a pH range of between 9 and 11. It appeared that the nitrate removal rate was 93% when the initial nitrate concentration and electrolysis time respectively were 100 mg L(-1)-NO(3)(-) and 40 min. The results showed a linear relationship between the electrolysis time for total nitrate removal and the initial nitrate concentration. It is concluded that the electrocoagulation technology for denitrification can be an effective preliminary process when the ammonia byproduct must be effectively removed by the treatment facilities.
Cruz-Uribe, Octavio; Rorrer, Gregory L
2006-02-20
Microplantlets of the marine red macroalga Portieria hornemannii efficiently removed the explosive compound 2,4,6-trinitrotoluene (TNT) from seawater. Photosynthetic, axenic microplantlets (1.2 g FW/L) were challenged with enriched seawater medium containing dissolved TNT at concentrations of 1.0, 10, and 50 mg/L. At 22 degrees C and initial TNT concentrations of 10 mg/L or less, TNT removal from seawater was 100% within 72 h, and the first-order rate constant for TNT removal ranged from 0.025 to 0.037 L/gFW h under both illuminated conditions (153 microE/m(2)s, 14:10 LD photoperiod) and dark conditions. Two immediate products of TNT biotransformation, 2-amino-4,6-dinitrotoluene and 4-amino-2,6-dintrotoluene, were identified in the liquid culture medium, with a maximum material balance recovery of 29 mole%. Only trace levels of these products and residual TNT were found within the fresh cell biomass. Removal of TNT by P. hornemannii microplantlets at initial concentrations of 1.0 or 10 mg/L did not affect the respiration rate. At an initial TNT concentration of 10 mg/L, net photosynthesis decreased towards zero, commensurate with the removal of dissolved TNT from seawater, whereas at an initial TNT concentration of 1.0 mg/L, the net photosynthesis rate was not affected. Copyright 2005 Wiley Periodicals, Inc.
COD removal characteristics in air-cathode microbial fuel cells.
Zhang, Xiaoyuan; He, Weihua; Ren, Lijiao; Stager, Jennifer; Evans, Patrick J; Logan, Bruce E
2015-01-01
Exoelectrogenic microorganisms in microbial fuel cells (MFCs) compete with other microorganisms for substrate. In order to understand how this affects removal rates, current generation, and coulombic efficiencies (CEs), substrate removal rates were compared in MFCs fed a single, readily biodegradable compound (acetate) or domestic wastewater (WW). Removal rates based on initial test conditions fit first-order kinetics, but rate constants varied with circuit resistance. With filtered WW (100Ω), the rate constant was 0.18h(-)(1), which was higher than acetate or filtered WW with an open circuit (0.10h(-)(1)), but CEs were much lower (15-24%) than acetate. With raw WW (100Ω), COD removal proceeded in two stages: a fast removal stage with high current production, followed by a slower removal with little current. While using MFCs increased COD removal rate due to current generation, secondary processes will be needed to reduce COD to levels suitable for discharge. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ammonia nitrogen removal from aqueous solution by local agricultural wastes
NASA Astrophysics Data System (ADS)
Azreen, I.; Lija, Y.; Zahrim, A. Y.
2017-06-01
Excess ammonia nitrogen in the waterways causes serious distortion to environment such as eutrophication and toxicity to aquatic organisms. Ammonia nitrogen removal from synthetic solution was investigated by using 40 local agricultural wastes as potential low cost adsorbent. Some of the adsorbent were able to remove ammonia nitrogen with adsorption capacity ranging from 0.58 mg/g to 3.58 mg/g. The highest adsorption capacity was recorded by Langsat peels with 3.58 mg/g followed by Jackfruit seeds and Moringa peels with 3.37 mg/g and 2.64 mg/g respectively. This experimental results show that the agricultural wastes can be utilized as biosorbent for ammonia nitrogen removal. The effect of initial ammonia nitrogen concentration, pH and stirring rate on the adsorption process were studied in batch experiment. The adsorption capacity reached maximum value at pH 7 with initial concentration of 500 mg/L and the removal rate decreased as stirring rate was applied.
Initiation of migration and movement rates of Atlantic salmon smolts in fresh water
Stich, Daniel S.; Kinnison, Michael T.; Kocik, John F.; Zydlewski, Joseph D.
2015-01-01
Timing of ocean entry is critical for marine survival of both hatchery and wild Atlantic salmon (Salmo salar) smolts. Management practices and barriers to migration such as dams may constrain timing of smolt migrations resulting in suboptimal performance at saltwater entry. We modeled influences of stocking location, smolt development, and environmental conditions on (i) initiation of migration by hatchery-reared smolts and (ii) movement rate of hatchery- and wild-reared Atlantic salmon smolts in the Penobscot River, Maine, USA, from 2005 through 2014 using acoustic telemetry data. We also compared movement rates in free-flowing reaches with rates in reaches with hydropower dams and head ponds. We compared movement rates before and after (1) removal of two mainstem dams and (2) construction of new powerhouses. Initiation of movement by hatchery fish was influenced by smolt development, stocking location, and environmental conditions. Smolts with the greatest gill Na+, K+-ATPase (NKA) activity initiated migration 24 h sooner than fish with the lowest gill NKA activity. Fish with the greatest cumulative thermal experience initiated migration 5 days earlier than those with lowest cumulative thermal experience. Smolts released furthest from the ocean initiated migration earlier than those released downstream, but movement rate increased by fivefold closer to the ocean, indicating behavioral trade-offs between initiation and movement rate. Dams had a strong effect on movement rate. Movement rate increased from 2.8 to 5.4 km·h−1 in reaches where dams were removed, but decreased from 2.1 to 0.1 km·h−1 in reaches where new powerhouses were constructed. Movement rate varied throughout the migratory period and was inversely related to temperature. Fish moved slower at extreme high or low discharge. Responses in fish movement rates to dam removal indicate the potential scope of recovery for these activities.
Treatment of Ammonia Nitrogen Wastewater in Low Concentration by Two-Stage Ozonization.
Luo, Xianping; Yan, Qun; Wang, Chunying; Luo, Caigui; Zhou, Nana; Jian, Chensheng
2015-09-23
Ammonia nitrogen wastewater (about 100 mg/L) was treated by two-stage ozone oxidation method. The effects of ozone flow rate and initial pH on ammonia removal were studied, and the mechanism of ammonia nitrogen removal by ozone oxidation was discussed. After the primary stage of ozone oxidation, the ammonia removal efficiency reached 59.32% and pH decreased to 6.63 under conditions of 1 L/min ozone flow rate and initial pH 11. Then, the removal efficiency could be over 85% (the left ammonia concentration was lower than 15 mg/L) after the second stage, which means the wastewater could have met the national discharge standards of China. Besides, the mechanism of ammonia removal by ozone oxidation was proposed by detecting the products of the oxidation: ozone oxidation directly and ·OH oxidation; ammonia was mainly transformed into NO₃(-)-N, less into NO₂(-)-N, not into N₂.
[Efficiency of photodecomposition of trace NDMA in water by UV irradiation].
Xu, Bing-Bing; Chen, Zhong-Lin; Qi, Fei; Ma, Jun
2008-07-01
Efficiency of photodecomposition of trace NDMA by UV irradiation was investigated with analyzing the initial concentration of NDMA, solution pH, irradiation area, irradiation intensity and water quality effect on NDMA photolysis. NDMA could be effectively photodegraded by UV irradiation. The removal efficiency of NDMA was 97.5% after 5 min of UV irradiation. Effect of initial NDMA concentration on photodecomposition of NDMA was not remarkable. With pH value ascending, the removal rate of NDMA photodecomposition decreased. The yields of photoquantum were more under lower solution pH than that under higher pH. NDMA had fastest reaction rate at solution pH = 2.2. Removal efficiency of NDMA increased with the available irradiation area ascending. Increscent ultraviolet irradiation intensity was good for NDMA degradation. Water quality affected the removal of NDMA slightly. The removal efficiency of NDMA in tap water and Songhua River raw water were 96.7% and 94.8%, respectively.
Removal of phenol by activated alumina bed in pulsed high-voltage electric field.
Zhu, Li-nan; Ma, Jun; Yang, Shi-dong
2007-01-01
A new process for removing the pollutants in aqueous solution-activated alumina bed in pulsed high-voltage electric field was investigated for the removal of phenol under different conditions. The experimental results indicated the increase in removal rate with increasing applied voltage, increasing pH value of the solution, aeration, and adding Fe2+. The removal rate of phenol could reach 72.1% when air aeration flow rate was 1200 ml/min, and 88.2% when 0.05 mmol/L Fe2+ was added into the solution under the conditions of applied voltage 25 kV, initial phenol concentration of 5 mg/L, and initial pH value 5.5. The addition of sodium carbonate reduced the phenol removal rate. In the pulsed high-voltage electric field, local discharge occurred at the surface of activated alumina, which promoted phenol degradation in the thin water film. At the same time, the space-time distribution of gas-liquid phases was more uniform and the contact areas of the activated species generated from the discharge and the pollutant molecules were much wider due to the effect of the activated alumina bed. The synthetical effects of the pulsed high-voltage electric field and the activated alumina particles accelerated phenol degradation.
Lai, Bo; Chen, Zhaoyu; Zhou, Yuexi; Yang, Ping; Wang, Juling; Chen, Zhiqiang
2013-04-15
In this study, the US-ZVI system was used to produce the strong reductants including H and nascent Fe(2+) ions to eliminate the toxicity of the high concentration p-nitrophenol (PNP) wastewater. The effect of the reactor structure, initial pH, ZVI dosage, ultrasonic power and initial PNP concentration on the removal efficiency of PNP from water was investigated intensively. The results show that a higher removal rate can be obtained by using a conical structure reactor, and the lower initial pH can aid the acceleration of PNP removal rate by using US-ZVI system. Furthermore, the removal efficiencies of PNP increased obviously with the increase of initial ZVI concentration from 0 to 15 gL(-1). Also, the treatment capacity of ZVI was enhanced remarkably by the ultrasonic irradiation, and the US-ZVI system can maintain high treatment efficiency for the high concentration PNP wastewater (500-10,000 mgL(-1)). Meanwhile, the high removal efficiency of PNP was mainly resulted from the synergistic reaction of ZVI and US. At last, the main degradation product (i.e., p-aminophenol) was detected by gas chromatography-mass spectrum (GC-MS). Thus, the reaction pathway of PNP in the US-ZVI system is proposed as a reducing process by the H and nascent Fe(2+) ions. Copyright © 2013 Elsevier B.V. All rights reserved.
Different removal behaviours of multiple trace antibiotics in municipal wastewater chlorination.
Li, Bing; Zhang, Tong
2013-06-01
The chlorination behaviours of 12 antibiotics belonging to six classes at environmentally relevant concentrations were systematically examined under typical conditions relevant to municipal wastewater chlorination. Cefotaxime, cefalexin, ampicillin and tetracycline were completely removed under all three initial free chlorine dosages (5 mg/L, 10 mg/L, and 15 mg/L). The removal efficiencies of sulphamethoxazole, sulphadiazine, roxithromycin, anhydro-erythromycin, ofloxacin, and trimethoprim were closely correlated to the residual free chlorine concentration, and no further significant mass removal was observed after the residual free chlorine concentration decreased to less than ≈ 0.75 mg/L. Ammonia plays a critical role during chlorination because of its competition with antibiotics for free chlorine to form combined chlorine, which reacts slowly with these antibiotics. Except for norfloxacin and ciprofloxacin, the removal behaviours of the 10 other target antibiotics under ammonia nitrogen concentrations ranging from 2 to 15 mg/L were characterised by a rapid initial removal rate upon contact with free chlorine during the first 5 s-1 min (depending on the specific antibiotic and ammonia nitrogen concentration) and then a much slower removal rate. Free chlorine was responsible for the reaction with antibiotics during the rapid stage (first 5 s-1 min), whereas combined chlorine reacted with antibiotics in the subsequent slow stage. Combined chlorine can remove norfloxacin and ciprofloxacin at a relatively faster rate. The presence of suspended solids at 30 mg/L slightly decreased the antibiotic removal rate. The kinetic rate constants decreased by 2.1-13.9%, while the half-lives increased by 2.0-15.0% compared to those of a 0 mg/L suspended solid for the target antibiotics. Copyright © 2013 Elsevier Ltd. All rights reserved.
Agrawal, Shantanu; Guest, Jeremy S; Cusick, Roland D
2018-04-01
To reduce intra-plant nutrient cycling, and recover phosphorus (P) fertilizers from nutrient-rich sidestreams, wastewater utilities increasingly elect to employ struvite precipitation processes without a clear understanding of the inherent tradeoffs associated with specific design and operating decisions. Specifically, the impact of reactor conditions on struvite crystallization rate, and distribution between formation of fines particles and secondary growth onto large diameter seed crystals represent critical knowledge gaps limiting the predictive capabilities of existing process models. In this work, the relative impacts of initial supersaturation (S i ), and seed loading, on P removal kinetics, and struvite solids distribution were investigated. In experiments conducted at different levels of initial supersaturation (1.7-2.4) and seed loading (0-25 g L -1 ), struvite fines represented the majority of phosphate solids formed in 10 of 12 conditions. While total P removal was dependent on S i , and primarily attributed to formation of fines, the concentration of struvite seed granules had a significant impact on the rate of P removal. Struvite seed granules increased the rate of precipitation by reducing induction time of primary nucleation of struvite fines. Secondary crystal growth represented the majority of struvite solids formed at high seed loading and low S i , but presented the tradeoff of low total removal and low rate of removal. To convey the significance of these findings on process modeling, we show how a prominent kinetic model with a first-order dependency on solid struvite concentration over-predicts P removal rate when total mass is dominated by large diameter seeds (0.9 mm). This works reveals the critical role of struvite fines in P removal, and highlights the need to account for their production and kinetic importance in struvite process design and operation. Copyright © 2018 Elsevier Ltd. All rights reserved.
Competitive Adsorption and Oxidation Behavior of Heavy Metals on nZVI Coated with TEOS.
Eglal, Mahmoud M; Ramamurthy, Amruthur S
2015-11-01
Zero valent iron nanoparticle (nanofer ZVI) is a powerful substance due to its coating with tetraethyl orthosilicate (TEOS). Tetraethyl orthosilicate imparts higher reactivity and decreases particle agglomeration. The competitive removal and displacement of multi-metals are influenced by time, pH, and initial concentration, the presence and properties of competing metals ion in the solution. For both the isotherm and kinetic studies performed for multi-metal removal experiments, compared to Pb II and Cd II, Cu II experienced a higher removal rate during the initial 5 minutes. After 120 minutes, all metals achieved removal efficiency in the range of 95 to 99%. The results of single and competitive kinetic tests for all three metals during the initial 5 minutes indicated that the presence of other metals generally reduce removal efficiency of metals. Both kinetic test and electron dispersive spectroscope (EDS) studies found that Cu II gets removed faster than the other metals. Pseudo-second order behavior was noted for the multi-metal removal systems.
Houseplants, Indoor Air Pollutants, and Allergic Reactions
NASA Technical Reports Server (NTRS)
Wolverton, B. C.
1986-01-01
The technology of using houseplant leaves for reducing volatile organics inside closed facilities has been demonstrated with formaldehyde and benzene. Philodendrons are among the most effective plants tested to date. Philodendron domesticum had demonstrated the ability to remove formaldehyde from small experimental chambers at a rate of 4.31 micro-g/sq cm leaf surface area with initial starting concentrations of 22 ppm. At initial starting concentrations of 2.3 ppm a formaldehyde removal rate of 0.57 micro-g/sq cm was achieved during a 24 hour test. Aleo vera demonstrated a much higher formaldehyde efficiency removal rate than Philodendron domesticum at low formaldehyde concentrations. During a 24 hour exposure period 5 ppm of formaldehyde were reduced to 0.5 ppm demonstrating a removal efficiency rate of 3.27 micro-g/sq cm. Removal efficiency rates can be expected to decrease with concentration levels because fewer molecules of chemicals come in contact with the leaf surface area. Several centimeters of small washed gravel should be used to cover the surface of pot plants when large numbers of plants are kept in the home. The reason for this is to reduce the exposed area of damp potting soil which encourages the growth of molds (fungi). The leaves of Philodendron domesticum and golden pothos (Scindapsus aureus) have also demonstrated their ability to remove benzene and carbon monoxide from closed chambers. A combination of activated carbon and plant roots have demonstrated the greatest potential for removing large volumes of volatile organics along with smoke and possible radon from closed systems. Although fewer plants are required for this concept a mechanical blower motor must be used to pull or push the air through the carbon-root filter. NASA studies on motor sizes and bioregeneration rates should be completed by 1988.
NASA Astrophysics Data System (ADS)
Amri, N.; Hashim, M. I.; Ismail, N.; Rohman, F. S.; Bashah, N. A. A.
2017-09-01
Electrocoagulation (EC) is a promising technology that extensively used to remove fluoride ions efficiently from industrial wastewater. However, it has received very little consideration and understanding on mechanism and factors that affecting the fluoride removal process. In order to determine the efficiency of fluoride removal in EC process, the effect of operating parameters such as voltage and electrolysis time were investigated in this study. A batch experiment with monopolar aluminium electrodes was conducted to identify the model of fluoride removal using empirical model equation. The EC process was investigated using several parameters which include voltage (3 - 12 V) and electrolysis time (0 - 60 minutes) at a constant initial fluoride concentration of 25 mg/L. The result shows that the fluoride removal efficiency increased steadily with increasing voltage and electrolysis time. The best fluoride removal efficiency was obtained with 94.8 % removal at 25 mg/L initial fluoride concentration, voltage of 12 V and 60 minutes electrolysis time. The results indicated that the rate constant, k and number of order, n decreased as the voltage increased. The rate of fluoride removal model was developed based on the empirical model equation using the correlation of k and n. Overall, the result showed that EC process can be considered as a potential alternative technology for fluoride removal in wastewater.
Treatment of Ammonia Nitrogen Wastewater in Low Concentration by Two-Stage Ozonization
Luo, Xianping; Yan, Qun; Wang, Chunying; Luo, Caigui; Zhou, Nana; Jian, Chensheng
2015-01-01
Ammonia nitrogen wastewater (about 100 mg/L) was treated by two-stage ozone oxidation method. The effects of ozone flow rate and initial pH on ammonia removal were studied, and the mechanism of ammonia nitrogen removal by ozone oxidation was discussed. After the primary stage of ozone oxidation, the ammonia removal efficiency reached 59.32% and pH decreased to 6.63 under conditions of 1 L/min ozone flow rate and initial pH 11. Then, the removal efficiency could be over 85% (the left ammonia concentration was lower than 15 mg/L) after the second stage, which means the wastewater could have met the national discharge standards of China. Besides, the mechanism of ammonia removal by ozone oxidation was proposed by detecting the products of the oxidation: ozone oxidation directly and ·OH oxidation; ammonia was mainly transformed into NO3−-N, less into NO2−-N, not into N2. PMID:26404353
Effective Degradation of Aqueous Tetracycline Using a Nano-TiO2/Carbon Electrocatalytic Membrane
Liu, Zhimeng; Zhu, Mengfu; Wang, Zheng; Wang, Hong; Deng, Cheng; Li, Kui
2016-01-01
In this work, an electrocatalytic membrane was prepared to degrade aqueous tetracycline (TC) using a carbon membrane coated with nano-TiO2 via a sol-gel process. SEM, XRD, EDS, and XPS were used to characterize the composition and structure of the electrocatalytic membrane. The effect of operating conditions on the removal rate of tetracycline was investigated systematically. The results show that the chemical oxygen demand (COD) removal rate increased with increasing residence time while it decreased with increasing the initial concentration of tetracycline. Moreover, pH had little effect on the removal of tetracycline, and the electrocatalytic membrane could effectively remove tetracycline with initial concentration of 50 mg·L−1 (pH, 3.8–9.6). The 100% tetracycline and 87.8% COD removal rate could be achieved under the following operating conditions: tetracycline concentration of 50 mg·L−1, current density of 1 mA·cm−2, temperature of 25 °C, and residence time of 4.4 min. This study provides a new and feasible method for removing antibiotics in water with the synergistic effect of electrocatalytic oxidation and membrane separation. It is evident that there will be a broad market for the application of electrocatalytic membrane in the field of antibiotic wastewater treatment. PMID:28773486
Electrochemical removal of phenol from oil refinery wastewater.
Abdelwahab, O; Amin, N K; El-Ashtoukhy, E-S Z
2009-04-30
This study explores the possibility of using electrocoagulation to remove phenol from oil refinery waste effluent using a cell with horizontally oriented aluminum cathode and a horizontal aluminum screen anode. The removal of phenol was investigated in terms of various parameters namely: pH, operating time, current density, initial phenol concentration and addition of NaCl. Removal of phenol during electrocoagulation was due to combined effect of sweep coagulation and adsorption. The results showed that, at high current density and solution pH 7, remarkable removal of 97% of phenol after 2h can be achieved. The rate of electrocoagulation was observed to increase as the phenol concentration decreases; the maximum removal rate was attained at 30 mg L(-1) phenol concentration. For a given current density using an array of closely packed Al screens as anode was found to be more effective than single screen anode, the percentage phenol removal was found to increase with increasing the number of screens per array. After 2h of electrocoagulation, 94.5% of initial phenol concentration was removed from the petroleum refinery wastewater. Energy consumption and aluminum Electrode consumption were calculated per gram of phenol removed. The present study shows that, electrocoagulation of phenol using aluminum electrodes is a promising process.
Liu, Tingyi; Yang, Xi; Wang, Zhong-Liang; Yan, Xiaoxing
2013-11-01
The removal of heavy metals from electroplating wastewater is a matter of paramount importance due to their high toxicity causing major environmental pollution problems. Nanoscale zero-valent iron (NZVI) became more effective to remove heavy metals from electroplating wastewater when enhanced chitosan (CS) beads were introduced as a support material in permeable reactive barriers (PRBs). The removal rate of Cr (VI) decreased with an increase of pH and initial Cr (VI) concentration. However, the removal rates of Cu (II), Cd (II) and Pb (II) increased with an increase of pH while decreased with an increase of their initial concentrations. The initial concentrations of heavy metals showed an effect on their removal sequence. Scanning electron microscope images showed that CS-NZVI beads enhanced by ethylene glycol diglycidyl ether (EGDE) had a loose and porous surface with a nucleus-shell structure. The pore size of the nucleus ranged from 19.2 to 138.6 μm with an average aperture size of around 58.6 μm. The shell showed a tube structure and electroplating wastewaters may reach NZVI through these tubes. X-ray photoelectron spectroscope (XPS) demonstrated that the reduction of Cr (VI) to Cr (III) was complete in less than 2 h. Cu (II) and Pb (II) were removed via predominant reduction and auxiliary adsorption. However, main adsorption and auxiliary reduction worked for the removal of Cd (II). The removal rate of total Cr, Cu (II), Cd (II) and Pb (II) from actual electroplating wastewater was 89.4%, 98.9%, 94.9% and 99.4%, respectively. The findings revealed that EGDE-CS-NZVI-beads PRBs had the capacity to remediate actual electroplating wastewater and may become an effective and promising technology for in situ remediation of heavy metals. Copyright © 2013 Elsevier Ltd. All rights reserved.
Density Driven Removal of Sediment from a Buoyant Muddy Plume
NASA Astrophysics Data System (ADS)
Rouhnia, M.; Strom, K.
2014-12-01
Experiments were conducted to study the effect of settling driven instabilities on sediment removal from hypopycnal plumes. Traditional approaches scale removal rates with particle settling velocity however, it has been suggested that the removal from buoyant suspensions happens at higher rates. The enhancement of removal is likely due to gravitational instabilities, such as fingering, at two-fluid interface. Previous studies have all sought to suppress flocculation, and no simple model exists to predict the removal rates under the effect of such instabilities. This study examines whether or not flocculation hampers instability formation and presents a simple removal rate model accounting for gravitational instabilities. A buoyant suspension of flocculated Kaolinite overlying a base of clear saltwater was investigated in a laboratory tank. Concentration was continuously measured in both layers with a pair of OBS sensors, and interface was monitored with digital cameras. Snapshots from the video were used to measure finger velocity. Samples of flocculated particles at the interface were extracted to retrieve floc size data using a floc camera. Flocculation did not stop creation of settling-driven fingers. A simple cylinder-based force balance model was capable of predicting finger velocity. Analogy of fingering process of fine grained suspensions to thermal plume formation and the concept of Grashof number enabled us to model finger spacing as a function of initial concentration. Finally, from geometry, the effective cross-sectional area was correlated to finger spacing. Reformulating the outward flux expression was done by substitution of finger velocity, rather than particle settling velocity, and finger area instead of total area. A box model along with the proposed outward flux was used to predict the SSC in buoyant layer. The model quantifies removal flux based on the initial SSC and is in good agreement with the experimental data.
Use of natural clinoptilolite for the removal of lead, copper and zinc in fixed bed column.
Stylianou, Marinos A; Hadjiconstantinou, Michalis P; Inglezakis, Vasilis J; Moustakas, Konstantinos G; Loizidou, Maria D
2007-05-08
This work deals with the removal of lead, copper and zinc from aqueous solutions by using natural zeolite (clinoptilolite). Fixed bed experiments were performed, using three different volumetric flow rates of 5, 7 and 10bed volume/h, under a total normality of 0.01N, at initial pH of 4 and ambient temperature (25 degrees C). The removal efficiency increased when decreasing the flow rate and the following selectivity series was found: Pb(2+)>Zn(2+)> or =Cu(2+). Conductivity measurements showed that lead removal follows mainly ion exchange mechanism, while copper and zinc removal follows ion exchange and sorption mechanism as well.
Altieri, Maria S; Yang, Jie; Telem, Dana A; Meng, Ziqi; Frenkel, Catherine; Halbert, Caitlin; Talamini, Mark; Pryor, Aurora D
2016-05-01
We sought to determine the rate of revision and explant of the laparoscopic adjustable gastric banding (LAGB) over a ten-year period in the state of New York. Following IRB approval, the SPARCS administrative database was used to identify LAGB placement from 2004 to 2010. We tracked patients who underwent band placement with subsequent removal/revision, followed by conversion to either Roux-en-Y gastric bypass (RYBG) or sleeve gastrectomy (SG) between 2004 and 2013. McNemar test and Chi-square test were used to compare complications between primary procedure and subsequent revision and to compare complication rates and mortality rates, respectively. Log-rank test was used to assess patient characteristics and comorbidities. p < 0.05 was considered significant. During a 7-year period, there were 19,221 records of LAGB placements and 6567 records of revisions or removal. We were able to follow up 3158 (16.43 %) who subsequently underwent a band removal or revision over the course of this period. An additional 3606 patients had no records in the state of New York following the procedure, thus making the rate of revision 20.22 %. Initial revision procedures were coded as band removal in 32.77 % (n = 1035), band revision in 30.53 % (n = 964), band removal and replacement in 19.09 % (n = 603), removal and conversion to SG in 5.64 % (n = 178), or removal and conversion to RYGB in 11.97 % (n = 378). From the 3158 patients, 2515 (79.64 %) required only one revision. Six hundred and forty-three patients underwent two or more revisions. Thirty-one out of 3158 (0.0098 %) patients had complications at their initial operation, but 919 (29.1 %) had complications during revision (p < 0.0001). Over a 7-year period, at least 20.22 % of LAGB required removal or revision. Based on all case numbers, total revision rate may be as high as 34.2 %. Although the band is believed to be a reversible procedure, revisional procedures are significantly more morbid than the initial procedure.
Ultrasound-assisted oxidative desulfurization of bunker-C oil using tert-butyl hydroperoxide.
Tang, Qiong; Lin, Song; Cheng, Ying; Liu, Sujun; Xiong, Jun-Ru
2013-09-01
This work investigated the ultrasonic assisted oxidative desulfurization of bunker-C oil with TBHP/MoO3 system. The operational parameters for the desulfurization procedure such as ultrasonic irradiation time, ultrasonic wave amplitude, catalyst initial concentration and oxidation agent initial concentration were studied. The experimental results show that the present oxidation system was very efficient for the desulfurization of bunker-C oil and ~35% sulfur was removed which was dependent on operational parameters. The application of ultrasonic irradiation allowed sulfur removal in a shorter time. The stronger the solvent polarity is, the higher the sulfur removal rate, but the recovery rate of oil is lower. The sulfur compounds in bunker-C oil reacted with TBHP to produce corresponding sulfoxide, and further oxidation produced the corresponding sulfone. Copyright © 2013 Elsevier B.V. All rights reserved.
Effect of pH on lead removal from water using tree fern as the sorbent.
Ho, Yuh-Shan
2005-07-01
The sorption of lead from water onto an agricultural by-product, tree fern, was examined as a function of pH. The sorption processes were carried out using an agitated and baffled system. Pseudo-second-order kinetic analyses were performed to determine the rate constant of sorption, the equilibrium sorption capacity, and the initial sorption rate. Application of the pseudo-second-order kinetics model produced very high coefficients of determination. Results showed the efficiency of tree fern as a sorbent for lead. The optimum pH for lead removal was between 4 and 7, with pH 4.9 resulting in better lead removal. Ion exchange occurred in the initial reaction period. In addition, a relation between the change in the solution hydrogen ion concentration and equilibrium capacity was developed and is presented.
Effect of pH and Fe/U ratio on the U(VI) removal rate by the synergistic effect of Fe(II) and O2
NASA Astrophysics Data System (ADS)
Fu, Yukui; Luo, Yingfeng; Fang, Qi; Xie, Yanpei; Wang, Zhihong; Zhu, Xiangyu
2018-02-01
As for the decommissioned uranium deposits of acid in-situ leaching, both of the concentrations of U(VI) and Fe(II) are relatively high in groundwater. In the presence of O2, the oxidation of Fe(II) into Fe(III) that forms Fe-hydroxides could effectively remove U(VI) in the forms of sorption or co-precipitation. In this process, pH condition and Fe content will have a significant effect on the U(VI) removal rate by the synergistic effect of Fe(II) and O2. In the present work, a series of batch experiments were carried out to investigate the effect of pH values and Fe/U mass ratio on the U(VI) removal rate by the synergistic effect of Fe(II) and O2. Experiment results show that the removal rate of U(VI) is mainly controlled by pH and secondly by Fe/U mass ratio. In the neutral conditions with pH at 7 and 8, the removal rate of U(VI) reaches up to 90% for all solutions with different initial Fe(II) concentrations. The optimal pH for the removal rate of U(VI) is above 7. In the acidic conditions with pH below 6, the effect of Fe/U mass ratio on the removal rate of U(VI) becomes more obvious and the optimal Fe/U mass ratio for U(VI) removal is 1:2.
Enhanced dimethyl phthalate biodegradation by accelerating phthalic acid di-oxygenation.
Tang, Yingxia; Zhang, Yongming; Jiang, Ling; Yang, Chao; Rittmann, Bruce E
2017-12-01
The aerobic biodegradation of dimethyl phthalate (DMP) is initiated with two hydrolysis reactions that generate an intermediate, phthalic acid (PA), that is further biodegraded through a two-step di-oxygenation reaction. DMP biodegradation is inhibited when PA accumulates, but DMP's biodegradation can be enhanced by adding an exogenous electron donor. We evaluated the effect of adding succinate, acetate, or formate as an exogenous electron donor. PA removal rates were increased by 15 and 30% for initial PA concentrations of 0.3 and 0.6 mM when 0.15 and 0.30 mM succinate, respectively, were added as exogenous electron donor. The same electron-equivalent additions of acetate and formate had the same acceleration impacts on PA removal. Consequently, the DMP-removal rate, even PA coexisting with DMP simultaneously, was accelerated by 37% by simultaneous addition of 0.3 mM succinate. Thus, lowering the accumulation of PA by addition of an electron increased the rate of DMP biodegradation.
Villegas, Manuel; Huiliñir, Cesar
2014-12-01
This study focuses on the kinetics of the biodegradation of volatile solids (VS) of sewage sludge for biodrying under different initial moisture contents (Mc) and air-flow rates (AFR). For the study, a 3(2) factorial design, whose factors were AFR (1, 2 or 3L/minkgTS) and initial Mc (59%, 68% and 78% w.b.), was used. Using seven kinetic models and a nonlinear regression method, kinetic parameters were estimated and the models were analyzed with two statistical indicators. Initial Mc of around 68% increases the temperature matrix and VS consumption, with higher moisture removal at lower initial Mc values. Lower AFRs gave higher matrix temperatures and VS consumption, while higher AFRs increased water removal. The kinetic models proposed successfully simulate VS biodegradation, with root mean square error (RMSE) between 0.007929 and 0.02744, and they can be used as a tool for satisfactory prediction of VS in biodrying. Copyright © 2014 Elsevier Ltd. All rights reserved.
Condition of live fire-scarred ponderosa pine eleven years after removing partial cross-sections
Emily K. Heyerdahl; Steven J. McKay
2008-01-01
Our objective is to report mortality rates for ponderosa pine trees in Oregon ten to eleven years after removing a fire-scarred partial cross-section from them, and five years after an initial survey of post-sampling mortality. We surveyed 138 live trees from which we removed fire-scarred partial crosssections in 1994/95 and 387 similarly sized, unsampled neighbor...
Khataee, Ali R; Khataee, Hamid R
2008-09-01
The present work deals with photooxidative removal of the herbicide, Acid Blue 9 (AB9), in water in the presence of hydrogen peroxide (H2O2) under UV light illumination (30 W). The influence of the basic operational parameters such as amount of H2O2, irradiation time and initial concentration of AB9 on the photodegradation efficiency of the herbicide was investigated. The degradation rate of AB9 was not appreciably high when the photolysis was carried out in the absence of H2O2 and it was negligible in the absence of UV light. The photooxidative removal of the herbicide was found to follow pseudo-first-order kinetic, and hence the figure-of-merit electrical energy per order (E Eo) was considered appropriate for estimating the electrical energy efficiency. A mathematical relation between the apparent reaction rate constant and H2O2 used was applied for prediction of the electricity consumption in the photooxidative removal of AB9. The results indicated that this kinetic model, based on the initial rates of degradation, provided good prediction of the E Eo values for a variety of conditions. The results also indicated that the UV/H2O2 process was appropriate as the effective treatment method for removal of AB9 from the contaminated wastewater.
Nitrate removal by Fe0/Pd/Cu nano-composite in groundwater.
Liu, Hongyuan; Guo, Min; Zhang, Yan
2014-01-01
Nitrate pollution in groundwater shows a great threat to the safety of drinking water. Chemical reduction by zero-valent iron is being considered as a promising technique for nitrate removal from contaminated groundwater. In this paper, Fe0/Pd/Cu nano-composites were prepared by the liquid-phase reduction method, and batch experiments of nitrate reduction by the prepared Fe0/Pd/Cu nano-composites under various operating conditions were carried out. It has been found that nano-Fe0/Pd/Cu composites processed dual functions: catalytic reduction and chemical reduction. The introduction of Pd and Cu not only improved nitrate removal rate, but also reduced the generation of ammonia. Nitrate removal rate was affected by the amount of Fe0/Pd/Cu, initial nitrate concentration, solution pH, dissolved oxygen (DO), reaction temperature, the presence of anions, and organic pollutant. Moreover, nitrate reduction by Fe0/Pd/Cu composites followed the pseudo-first-order reaction kinetics. The removal rate of nitrate and total nitrogen were about 85% and 40.8%, respectively, under the reaction condition of Fe-6.0%Pd-3.0%Cu amount of 0.25 g/L, pH value of 7.1, DO of 0.42 mg/L, and initial nitrate concentration of 100 mg/L. Compared with the previous studies with Fe0 alone or Fe-Cu, nano-Fe-6%Pd-3%Cu composites showed a better selectivity to N2.
Macedo, R G; Robinson, J P; Verhaagen, B; Walmsley, A D; Versluis, M; Cooper, P R; van der Sluis, L W M
2014-11-01
To introduce and characterize a reproducible hydrogel as a suitable biofilm mimic in endodontic research. To monitor and visualize the removal of hydrogel from a simulated lateral canal and isthmus for the following: I) Ultrasonic-Activated Irrigation (UAI) with water, ii) UAI with NaOCl and iii) NaOCl without UAI. A rheometer was used to characterize the viscoelastic properties and cohesive strength of the hydrogel for suitability as a biofilm mimic. The removal rate of the hydrogel from a simulated lateral canal or isthmus was measured by high-speed imaging operating at frame rates from 50 to 30,000 fps. The hydrogel demonstrated viscoelastic behaviour with mechanical properties comparable to real biofilms. UAI enhanced the cleaning effect of NaOCl in isthmi (P < 0.001) and both NaOCl and water in lateral canals (P < 0.001). A greater depth of cleaning was achieved from an isthmus (P = 0.009) than from a lateral canal with UAI and also at a faster rate for the first 20 s. NaOCl without UAI resulted in a greater depth of hydrogel removal from a lateral canal than an isthmus (P < 0.001). The effect of UAI was reduced when stable bubbles were formed and trapped in the lateral canal. Different removal characteristics were observed in the isthmus and the lateral canal, with initial highly unstable behaviour followed by slower viscous removal inside the isthmus. The biofilm-mimicking hydrogel is reproducible, homogenous and can be easily applied and modified. Visualization of its removal from lateral canal anatomy provides insights into the cleaning mechanisms of UAI for a biofilm-like material. Initial results showed that UAI improves hydrogel removal from the accessory canal anatomy, but the creation of stable bubbles on the hydrogel-liquid interface may reduce the cleaning rate. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Xing, Kun; Wang, Hai-Zeng
2013-04-01
Powder layered double hydroxide of Mg-Al LDH were prepared by hydrothermal technology with 500 kg x batch(-1), modified and granulated (MG Mg-Al CLDH) by deposition method. After the modification and granulation, the fixed bed can not be accumulated and clogged by the adsorbents. The PO4(3-) is removed from aqueous solution, wastewater and seawater by MG Mg-Al CLDH with column experiments. It shows that MG Mg-Al CLDH is an effective adsorbent. After removal, the water quality can satisfy with the first degree of integrated wastewater discharge or seawater standards. The mechanism of removal PO4(3-) is ion exchange and 'memory effect'. The breakthrough adsorption capacity of PO4(3-) from solution is 13.49 mg x g(-1), more than 6 times higher than that by Mg-Al LDH without modification. The exhausted MG Mg-Al CLDH can be desorbed with 0.1 mol x L(-1) NaOH and 3 mol x L(-1) NaCl and regenerated with 25% MgCl2. The regeneration rate is 126.24%. The breakthrough curves are influenced by bed depth, flow rate, initial concentration and initial pH. The adsorption processes are controlled by film diffusion. When the initial concentration is as low as 0.38 micromol x L(-1), PO4(3-) can be removed from seawater to satisfy with the first degree of seawater quality. So this work is very useful for the practical application of Mg-Al LDH and the removal of phosphorus.
Jiang, Yu; Wang, Hongyu; Shang, Yu; Yang, Kai
2016-05-01
The high removal efficiencies of traditional biological aniline-degrading systems always lead to accumulation of ammonium. In this study, simultaneous removal of aniline, nitrogen and phosphorus in a single sequencing batch reactor was achieved by using anaerobic/aerobic/anoxic (A/O/A) operational process. The removal efficiencies of COD, NH4(+)-N, TN, TP were over 95.80%, 83.03%, 87.13%, 90.95%, respectively in most cases with 250mgL(-1) of initial aniline at 6h cycle when DO was 5.5±0.5mgL(-1). Aniline was able to be completely degraded when initial concentrations were less than 750mgL(-1). When DO increased, the removal rate of NH4(+)-N and TP slightly increased along with the moderate decrease of removal efficiencies of TN. The variation of HRT had obvious influence on removal performance of pollutants. The system showed high removal efficiencies of aniline, COD and nutrients during the variation of operating conditions, which might contribute to disposal of aniline-rich industrial wastewater. Copyright © 2016 Elsevier Ltd. All rights reserved.
Praveen, Prashant; Loh, Kai-Chee
2015-12-01
Chlorella vulgaris encapsulated in alginate beads were added into a bioreactor treating synthetic wastewater using Pseudomonas putida. A symbiotic CO2/O2 gas exchange was established between the two microorganisms for photosynthetic aeration of wastewater. During batch operation, glucose removal efficiency in the bioreactor improved from 50% in 12 h without aeration to 100% in 6 h, when the bioreactor was aerated photosynthetically. During continuous operation, the bioreactor was operated at a low hydraulic retention time of 3.3 h at feed concentrations of 250 and 500 mg/L glucose. The removal efficiency at 500 mg/L increased from 73% without aeration to 100% in the presence of immobilized microalgae. The initial microalgae concentration was critical to achieve adequate aeration, and the removal rate increased with increasing microalgae concentration. The highest removal rate of 142 mg/L-h glucose was achieved at an initial microalgae concentration of 190 mg/L. Quantification of microalgae growth in the alginate beads indicated an exponential growth during symbiosis, indicating that the bioreactor performance was limited by oxygen production rates. Under symbiotic conditions, the chlorophyll content of the immobilized microalgae increased by more than 30%. These results indicate that immobilized microalgae in symbiosis with heterotrophic bacteria are promising in wastewater aeration.
Initial experience using the rigid forceps technique to remove wall-embedded IVC filters.
Avery, Allan; Stephens, Maximilian; Redmond, Kendal; Harper, John
2015-06-01
Severely tilted and embedded inferior vena cava (IVC) filters remain the most challenging IVC filters to remove. Heavy endothelialisation over the filter hook can prevent engagement with standard snare and cone recovery techniques. The rigid forceps technique offers a way to dissect the endothelial cap and reliably retrieve severely tilted and embedded filters. By developing this technique, failed IVC retrieval rates can be significantly reduced and the optimum safety profile offered by temporary filters can be achieved. We present our initial experience with the rigid forceps technique described by Stavropoulos et al. for removing wall-embedded IVC filters. We retrospectively reviewed the medical imaging and patient records of all patients who underwent a rigid forceps filter removal over a 22-month period across two tertiary referral institutions. The rigid forceps technique had a success rate of 85% (11/13) for IVC filter removals. All filters in the series showed evidence of filter tilt and embedding of the filter hook into the IVC wall. Average filter tilt from the Z-axis was 19 degrees (range 8-56). Filters observed in the case study were either Bard G2X (n = 6) or Cook Celect (n = 7). Average filter dwell time was 421 days (range 47-1053). There were no major complications observed. The rigid forceps technique can be readily emulated and is a safe and effective technique to remove severely tilted and embedded IVC filters. The development of this technique across both institutions has increased the successful filter removal rate, with perceived benefits to the safety profile of our IVC filter programme. © 2015 The Royal Australian and New Zealand College of Radiologists.
Yu, Dahai; Yang, Jiyu; Fang, Xuexun; Ren, Hejun
2015-01-01
Bioaugmentation is a promising technology for pollutant elimination from stressed environments, and it would provide an efficient way to solve challenges in traditional biotreatment of wastewater with high strength of ammonia nitrogen (NH4(+)-N). A high NH4(+)-N-resistant bacteria strain, identified as Bacillus cereus (Jlu BC), was domesticated and isolated from the bacteria consortium in landfill leachate. Jlu BC could survive in 100 g/L NH4(+)-N environment, which indicated its extremely high NH4(+)-N tolerance than the stains found before. Jlu BC was employed in the bioaugmented system to remove high strength of NH4(+)-N from landfill leachate, and to increase the removal efficiency, response surface methodology (RSM) was used for optimizing bioaugmentation degradation conditions. At the optimum condition (initial pH 7.33, 4.14 days, initial chemical oxygen demand [COD] concentration [18,000 mg/L], 3.5 mL inoculated domesticated bacteria strain, 0.3 mg/mL phosphorus supplement, 30 °C, and 170 rpm), 94.74 ± 3.8% removal rate of NH4(+)-N was obtained, and the experiment data corresponded well with the predicted removal rate of the RSM models (95.50%). Furthermore, COD removal rate of 81.94 ± 1.4% was obtained simultaneously. The results presented are promising, and the screened strain would be of great practical importance in mature landfill leachate and other NH4(+)-N enrichment wastewater pollution control. © 2014 International Union of Biochemistry and Molecular Biology, Inc.
Influence of the implant-abutment connection design and diameter on the screw joint stability.
Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung; Jeong, Chang-Mo
2014-04-01
This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). THE POSTLOAD REMOVAL TORQUE VALUE WAS HIGH IN THE FOLLOWING ORDER WITH REGARD TO MAGNITUDE: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.
Influence of the implant-abutment connection design and diameter on the screw joint stability
Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung
2014-01-01
PURPOSE This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). RESULTS The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate. PMID:24843398
Aerobic cyanide degradation by bacterial isolates from cassava factory wastewater
Kandasamy, Sujatha; Dananjeyan, Balachandar; Krishnamurthy, Kumar; Benckiser, Gero
2015-01-01
Ten bacterial strains that utilize cyanide (CN) as a nitrogen source were isolated from cassava factory wastewater after enrichment in a liquid media containing sodium cyanide (1 mM) and glucose (0.2% w/v). The strains could tolerate and grow in cyanide concentrations of up to 5 mM. Increased cyanide levels in the media caused an extension of lag phase in the bacterial growth indicating that they need some period of acclimatisation. The rate of cyanide removal by the strains depends on the initial cyanide and glucose concentrations. When initial cyanide and glucose concentrations were increased up to 5 mM, cyanide removal rate increased up to 63 and 61 per cent by Bacillus pumilus and Pseudomonas putida. Metabolic products such as ammonia and formate were detected in culture supernatants, suggesting a direct hydrolytic pathway without an intermediate formamide. The study clearly demonstrates the potential of aerobic treatment with cyanide degrading bacteria for cyanide removal in cassava factory wastewaters. PMID:26413045
Aerobic cyanide degradation by bacterial isolates from cassava factory wastewater.
Kandasamy, Sujatha; Dananjeyan, Balachandar; Krishnamurthy, Kumar; Benckiser, Gero
2015-01-01
Ten bacterial strains that utilize cyanide (CN) as a nitrogen source were isolated from cassava factory wastewater after enrichment in a liquid media containing sodium cyanide (1 mM) and glucose (0.2% w/v). The strains could tolerate and grow in cyanide concentrations of up to 5 mM. Increased cyanide levels in the media caused an extension of lag phase in the bacterial growth indicating that they need some period of acclimatisation. The rate of cyanide removal by the strains depends on the initial cyanide and glucose concentrations. When initial cyanide and glucose concentrations were increased up to 5 mM, cyanide removal rate increased up to 63 and 61 per cent by Bacillus pumilus and Pseudomonas putida. Metabolic products such as ammonia and formate were detected in culture supernatants, suggesting a direct hydrolytic pathway without an intermediate formamide. The study clearly demonstrates the potential of aerobic treatment with cyanide degrading bacteria for cyanide removal in cassava factory wastewaters.
Zhang, Ruo-Bing; Wu, Yan; Li, Guo-Feng; Wang, Ning-Hui; Li, Jie
2004-01-01
Degradation of the Indigo Carmine (IC) by the bipolar pulsed DBD in water-air mixture was studied. Effects of various parameters such as gas flow rate, solution conductivity, pulse repetitive rate and ect., on color removal efficiency of dying wastewater were investigated. Concentrations of gas phase o3 and aqueous phase H2O2 under various conditions were measured. Experimental results showed that air bubbling facilitates the breakdown of water and promotes generation of chemically active species. Color removal efficiency of IC solution can be greatly improved by the air aeration under various solution conductivities. Decolorization efficiency increases with the increase of the gas flow rate, and decreases with the increase of the initial solution conductivity. A higher pulse repetitive rate and a larger pulse capacitor C(p) are favorable for the decolorization process. Ozone and hydrogen peroxide formed decreases with the increase of initial solution conductivity. In addition, preliminary analysis of the decolorization mechanisms is given.
Study on Adsorption of Chromium (VI) by Activated Carbon from Cassava Sludge
NASA Astrophysics Data System (ADS)
Yang, Jinhui; Li, Chuanshu; Yang, Bin; Kang, Sijun; Zhang, Zhen
2018-03-01
In this paper, a new type of adsorbent prepared by waste sludge from alcohol production industry was used to adsorb Cr (VI) in activated carbon from cassava sludge. A series of static adsorption experiments were carried out on the initial concentration of solution Cr (VI), pH value of solution, adsorption time and dosage of adsorbent. The results of single factor experiments show that the removal rate of Cr (VI) increases with the initial concentration of Cr(VI), while the adsorption amount is opposite. When the pH value of the solution is low, the adsorption effect of activated carbon is better.The adsorption time should be controlled within 40-60min. When the activated carbon dosage is increased, the removal rate increases but the adsorption capacity decreases.
Semerjian, Lucy; Damaj, Ahmad; Salam, Darine
2015-11-01
The current study aims at investigating the efficiency of electrocoagulation for the removal of humic acid from contaminated waters. In parallel, conventional chemical coagulation was conducted to asses humic acid removal patterns. The effect of varying contributing parameters (matrix pH, humic acid concentration, type of electrode (aluminum vs. iron), current density, solution conductivity, and distance between electrodes) was considered to optimize the electrocoagulation process for the best attainable humic acid removal efficiencies. Optimum removals were recorded at pH of 5.0-5.5, an electrical conductivity of 3000 μS/cm at 25 °C, and an electrode distance of 1 cm for both electrode types. With aluminum electrodes, a current density of 0.05 mA/cm2 outperformed 0.1 mA/cm2 yet not higher densities, whereas a current density of 0.8 mA/cm2 was needed for iron electrodes to exhibit comparable performance. With both electrode types, higher initial humic acid concentrations were removed at a slower rate but ultimately attained almost complete removals. On the other hand, the best humic acid removals (∼90%) by chemical coagulation were achieved at 4 mg/L for both coagulants. Also, higher removals were attained at elevated initial humic acid concentrations. Humic acid removals of 90% or higher at an initial HA concentration of 40 mg/L were exhibited, yet alum performed better at the highest experimented concentration. It was evident that iron flocs were larger, denser, and more geometrical in shape compared to aluminum flocs.
Converter slag-coal cinder columns for the removal of phosphorous and other pollutants.
Yang, Jian; Wang, Su; Lu, Zhibo; Yang, Jian; Lou, Shanjie
2009-08-30
A mixture of converter slag and coal cinder as adsorbent for the removal of phosphorous and other pollutants was studied in the paper. The maximum P adsorption capacity, pH of solution, contact time and initial phosphate concentration were evaluated in batch experiments for the two materials firstly. The data of P sorption were best fitted to Langumir equation, and the maximum adsorption capacities of converter slag and coal cinder were 2.417 and 0.398 mg P/g, respectively. The pH of solutions with converter slag and coal cinder changed dramatically with time and closed to 8 in 8h, and the influence of initial pH on phosphate removal by coal cinder was more significant than by converter slag. Phosphate removal rate by converter slag decreased with increase of initial phosphate concentrations. Subsequently, two flow-through columns (Column 1#, V(converter slag):V(coal cinder)=1:5; Column 2#, V(converter slag):V(coal cinder)=1:3) were operated for the removal of phosphorous and other pollutants from the effluents of a vermifilter for nearly eleven months. Results indicated the average removal efficiency of total phosphorus, dissolved phosphorus, COD and NH(4)(+)-N by Column 1# were 44%, 56%, 31% and 67%, and by Column 2# were 42%, 54%, 24% and 57%, respectively. Column 1# had higher removal efficiency for P and other pollutants.
Decomposition of mixed malodorants in a wire-plate pulse corona reactor.
Shi, Y; Ruan, J; Wang, X; Li, W; Tan, T
2005-09-01
Decomposition characteristics of two groups of representative mixed malodorants (1, ethanethiol + hydrogen sulfide; 2, ethanethiol + ammonia) in air were investigated employing a wire-plate pulse corona reactor. A new type of high-voltage pulse generator with a thyratron switch and a Blumlein pulse-forming network (BPFN) was used in our experiments. The experiments were conducted at a gas-flow rate of 13 m3/h. Important parameters, including peak voltage, chemical structures of malodorants, pulse frequency, and initial concentration, which influenced the removal efficiency, were investigated. The results showed that the mixed malodorants could be treated effectively by pulse corona. The removal efficiencies of 200 mg/m3 C2H5SH and 200 mg/m3 H2S for group 1 were 95.6% and 100%, respectively, which were almost equal to those of the two pollutants separately. The energy cost was about 65.1-81.4 J/L, which was 31.5-45.2% lower than for treating pollutants alone. The removal efficiencies of 105 mg/m3 C2HsSH and 40 mg/m3 NH3 for group 2 were 93.1% and almost 100%, and the energy cost was 65.1 J/L, 55.6% lower than that which was treated separately. In the case of two groups of mixed malodorants removal, NOx, 03, SO2, CO2, and CO were all observed. Moreover, some sulfur and white crystal ammonium nitrates were discovered adhering to the corona wires in the removal of groups 1 and 2, respectively. A dynamics model was developed to describe the relation of the removal efficiency with specific energy density and initial concentration. In the case of group 1 removal,the decomposition rate constants decreased as compared to the single treating. As for group 2 removal, the decomposition rate constants increased, especially for NH3. According to the results, the optimization design for the reactor and the matching of high pulse voltage source can be reckoned.
Chlorbromuron urea herbicide removal by electro-Fenton reaction in aqueous effluents.
Martínez, Susana Silva; Bahena, Cristina Lizama
2009-01-01
The removal of low concentration of chlorbromuron herbicide in aqueous systems was carried out by electro-Fenton process comprised of three-electrode divided and undivided cell with a reticulated vitreous carbon cathode and platinum anode. The electro-Fenton was also carried out in a two-electrode undivided cell in which ferrous ion forms from a sacrificial iron anode. It was observed that the total organic carbon (TOC) removal efficiency was influenced by the cell voltage, the pH of the solution and initial herbicide concentration during the electro-Fenton treatment with a stainless steel anode. The Fe(2+)/Fe(3+) activity in the Fenton chemistry (regardless if it is hydroxyl radical or ferryl ion) was improved by the electrochemical catalysis leading to a TOC analysis below the detection limit (0.2 mg l(-1)) corresponding to a TOC removal over 98%. It was found that TOC removal during chlorbromuron degradation followed apparent first order kinetics. The rate constant was increased by decreasing the initial concentration of chlorbromuron.
Selewski, David T; Cornell, Timothy T; Blatt, Neal B; Han, Yong Y; Mottes, Theresa; Kommareddi, Mallika; Gaies, Michael G; Annich, Gail M; Kershaw, David B; Shanley, Thomas P; Heung, Michael
2012-01-01
Objective In pediatric patients fluid overload (FO) at continuous renal replacement (CRRT) initiation is associated with increased mortality. The aim of this study was to characterize the association between fluid overload at CRRT initiation, fluid removal during CRRT, the kinetics of fluid removal and mortality in a large pediatric population receiving CRRT while on extracorporeal membrane oxygenation (ECMO). Design Retrospective chart review. Setting Tertiary children’s hospital Patients ECMO patients requiring CRRT from July 2006 to September 2010 Interventions None Measurements and Main Results Overall ICU survival was 34% for 53 patients that were initiated on CRRT while on ECMO during the study period. Median FO at CRRT initiation was significantly lower in survivors compared to non-survivors (24.5 vs. 38%, p=0.006). Median FO at CRRT discontinuation was significantly lower in survivors compared to non-survivors (7.1 vs. 17.5%, p=0.035). After adjusting for percent FO at CRRT initiation, age and severity of illness, the change in FO at CRRT discontinuation was not significantly associated with mortality (p=0.212). Models investigating the rates of fluid removal in different periods, age, severity of illness and fluid overload at CRRT initiation found that fluid overload at CRRT initiation was the most consistent predictor of survival. Conclusions Our data demonstrates an association between FO at CRRT initiation and mortality in pediatric patients receiving ECMO. The degree of FO at CRRT discontinuation is also associated with mortality, but appears to reflect the effect of FO at initiation. Furthermore, correction of FO to ≤ 10% was not associated with improved survival. These results suggest that intervening prior to the development of significant FO may be more clinically effective than attempting fluid removal after significant fluid overload has developed. Our findings suggest a role for earlier initiation of CRRT in this population, and warrant further clinical studies. PMID:22743776
UV light assisted decolorization of dark brown colored coffee effluent by photo-Fenton reaction.
Tokumura, Masahiro; Ohta, Ayano; Znad, Hussein T; Kawase, Yoshinori
2006-12-01
The photochemical decolorization of coffee effluent has been examined by photo-Fenton (UV/Fe2+/H2O2) process. Effects of UV light intensity, initial coffee concentration, iron dose and H2O2 dose on the color removal of model coffee effluent have been investigated. The rate of decolorization increased with decreasing initial coffee effluent concentration. It was found that the Fe ion dose and UV light intensity enhanced the decolorization rate. The decolorization process of coffee effluent could be divided into three established phases. At the beginning of the photo-Fenton process, the instantaneous and significant increase in color of the solution was found (Phase-I). In the subsequent phase (Phase-II), the decolorization rate was initially fast and subsequently decreased. In Phase-III, the rate was accelerated and then the complete decolorization of model coffee effluent was achieved. In order to elucidate the mechanisms of coffee effluent color removal process, the concentration changes in Fe3+ and Fe2+ besides H2O2 were measured during the course of the photo-Fenton process. The rate-determining step in Phase-II was the photo-Fenton reaction or photoreduction of Fe3+. On the other hand, the decolorization process in Phase-III was highly affected by Fenton reaction or decomposition of H2O2 with Fe2+. About 93% mineralization of 250 mg L(-1) model coffee effluent was achieved after 250 min. A comparative study for TiO2, ZnO and photo-Fenton oxidation processes has been also carried out and the photo-Fenton process was found to be the most effective for color removal of coffee effluent.
Cho, Seonghyeon; Kim, Jinsoo; Kim, Sungchul; Lee, Sang-Seob
2017-06-22
We screened and identified a NH 3 -N-removing bacterial strain, Bacillus sp. KGN1, and a [Formula: see text] removing strain, Vibrio sp. KGP1, from 960 indigenous marine isolates from seawater and marine sediment from Tongyeong, South Korea. We developed eco-friendly high-efficiency marine sludge (eco-HEMS), and inoculated these marine bacterial strains into the marine sediment. A laboratory-scale sequencing batch reactor (SBR) system using the eco-HEMS for marine wastewater from land-based fish farms improved the treatment performance as indicated by 88.2% removal efficiency (RE) of total nitrogen (initial: 5.6 mg/L) and 90.6% RE of total phosphorus (initial: 1.2 mg/L) under the optimal operation conditions (food and microorganism (F/M) ratio, 0.35 g SCOD Cr /g mixed liquor volatile suspended solids (MLVSS)·d; dissolved oxygen (DO) 1.0 ± 0.2 mg/L; hydraulic retention time (HRT), 6.6 h; solids retention time (SRT), 12 d). The following kinetic parameters were obtained: cell yield (Y), 0.29 g MLVSS/g SCOD Cr ; specific growth rate (µ), 0.06 d -1 ; specific nitrification rate (SNR), 0.49 mg NH 3 -N/g MLVSS·h; specific denitrification rate (SDNR), 0.005 mg [Formula: see text]/g MLVSS·h; specific phosphorus uptake rate (SPUR), 0.12 mg [Formula: see text]/g MLVSS·h. The nitrogen- and phosphorus-removing bacterial strains comprised 18.4% of distribution rate in the microbial community of eco-HEMS under the optimal operation conditions. Therefore, eco-HEMS effectively removed nitrogen and phosphorus from highly saline marine wastewater from land-based fish farms with improving SNR, SDNR, and SPUR values in more diverse microbial communities. DO: dissolved oxygen; Eco-HEMS: eco-friendly high efficiency marine sludge; F/M: food and microorganism ratio; HRT: hydraulic retention time; ML(V)SS: mixed liquor (volatile) suspended solids; NCBI: National Center for Biotechnology Information; ND: not determined; qPCR: quantitative real-time polymerase chain reaction; RE: removal efficiency; SBR: sequencing batch reactor; SD: standard deviation; SDNR: specific denitrification rate; SNR: specific nitrification rate; SPUR: specific phosphate uptake rate; SRT: solids retention time; T-N: total nitrogen; T-P: total phosphorus; (V)SS: (volatile) suspended solids; w.w.: wet weight.
Phytoremediation removal rates of benzene, toluene, and chlorobenzene.
Limmer, Matt A; Wilson, Jordan; Westenberg, David; Lee, Amy; Siegman, Mark; Burken, Joel G
2018-06-07
Phytoremediation is a sustainable remedial approach, although performance efficacy is rarely reported. In this study, we assessed a phytoremediation plot treating benzene, toluene, and chlorobenzene. A comparison of the calculated phytoremediation removal rate with estimates of onsite contaminant mass was used to forecast cleanup periods. The investigation demonstrated that substantial microbial degradation was occurring in the subsurface. Estimates of transpiration indicated that the trees planted were removing approximately 240,000 L of water per year. This large quantity of water removal implies substantial removal of contaminant due to large amounts of contaminants in the groundwater; however, these contaminants extensively sorb to the soil, resulting in large quantities of contaminant mass in the subsurface. The total estimate of subsurface contaminant mass was also complicated by the presence of non-aqueous phase liquids (NAPL), additional contaminant masses that were difficult to quantify. These uncertainties of initial contaminant mass at the site result in large uncertainty in the cleanup period, although mean estimates are on the order of decades. Collectively, the model indicates contaminant removal rates on the order of 10 -2 -10 0 kg/tree/year. The benefit of the phytoremediation system is relatively sustainable cleanup over the long periods necessary due to the presence of NAPL.
Hydrogen peroxide-enhanced iron-mediated aeration for the treatment of mature landfill leachate.
Deng, Yang; Englehardt, James D
2008-05-01
Municipal landfill leachate is being disallowed for biological treatment by some sewer authorities due to its recalcitrance and corrosiveness, and therefore physicochemical treatment may be needed. In this paper, hydrogen peroxide-enhanced iron (Fe(0))-mediated aeration (IMA) was studied as an alternative for the treatment of mature landfill leachate. Bench-scale Taguchi array screening tests and full factorial tests were conducted. Iron grade, initial pH, H(2)O(2) addition rate, and aeration rate significantly influenced both overall chemical oxygen demand (COD) removal and iron consumption. In the enhanced IMA-treated leachate at an initial pH of 8.2, COD was reduced by 50% due to oxidation and coagulation, a level almost equivalent to those obtained by Fenton treatment. Meanwhile, the 5-day biochemical oxygen demand (BOD(5))/COD ratio was increased from 0.02 to 0.17. In particular, the effect of initial pH became minor at H(2)O(2) addition rate greater than the theoretical demand for complete oxidation of organics by H(2)O(2). In addition, 83% of 300 mg/L ammonia nitrogen and 38% of 8.30 mS/cm electrical conductivity were removed when the initial pH was not adjusted. Based on these results, the process appears suitable for treatment of mature leachate.
Varanasi, Lakshman; Hosler, Jonathan P.
2011-01-01
We review studies of subunit III-depleted cytochrome c oxidase (CcO III (−)) that elucidate the structural basis of steady-state proton uptake from solvent into an internal proton transfer pathway. The removal of subunit III from R. sphaeroides CcO makes proton uptake into the D pathway a rate-determining step, such that measurements of the pH dependence of steady-state O2 consumption can be used to compare the rate and functional pKa of proton uptake by D pathways containing different initial proton acceptors. The removal of subunit III also promotes spontaneous suicide inactivation by CcO, greatly shortening its catalytic lifespan. Because the probability of suicide inactivation is controlled by the rate at which the D pathway delivers protons to the active site, measurements of catalytic lifespan provide a second method to compare the relative efficacy of proton uptake by engineered CcO III (−) forms. These simple experimental systems have been used to explore general questions of proton uptake by proteins, such as the functional value of an initial proton acceptor, whether an initial acceptor must be surface-exposed, which side chains will function as initial proton acceptors and whether multiple acceptors can speed proton uptake. PMID:22023935
Using MOF-74 for Hg{sup 2+} removal from ultra-low concentration aqueous solution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiong, Yang Yang; Li, Jian Qiang; Gong, Le Le
Mercury (Hg{sup 2+}) ions have very high toxicity and widely spread as environmental pollutants. At present, many efforts have been taken to remove the hazardous materials of mercury(II) by adsorption, and it is highly desirable to develop a novel adsorbent with high adsorptive capacities. However it is still a big challenge to remove the ultra-low-concentration mercury ions from water. In this paper, MOF-74-Zn is explored for such function, showing high removal rate of Hg(II) from water without any pretreatment, especially for the ultra-trace Hg(II) ions in the ppb magnitude with the removal rate reaching to 54.48%, 69.71%, 72.26% when themore » initial concentration of Hg(II) is 20ppb, 40ppb, 50ppb, respectively. - Graphical abstract: The absorption of mercury ions on MOF-74-Zn is due to somewhat weak interactions between MOF skeleton that is composed of carboxylate and hydroxy group and Hg2+ ions. - Highlights: • MOF-74-Zn shows high removal rate of Hg(II) from water without any pretreatment. • The MOF-74-Zn has a notable performance at ultra-low concentration of Hg(II). • MOF-74-Zn shows the potential for Hg(II) removal from industrial waste water.« less
Glucagon Is a Safe and Inexpensive Initial Strategy in Esophageal Food Bolus Impaction.
Haas, Jason; Leo, Julia; Vakil, Nimish
2016-03-01
Controversy exists about the utility of pharmacologic agents and endoscopic technique used for esophageal food bolus impaction. To evaluate the utility of glucagon and the technique used for endoscopic removal, including the rate of success and the adverse events of the techniques. The database of the largest healthcare provider in southeastern Wisconsin was retrospectively reviewed for patients presenting with esophageal food bolus impaction. Data extracted included glucagon administration and its success rate, outcome of radiographic studies, and the endoscopic method of removal and adverse events associated with it, including 30-day mortality. A total of 750 patients were identified with food bolus impaction from 2007 to 2012. Glucagon was administered in 440 patients and was successful in 174 (39.5%). Endoscopic removal was performed in 470 patients and was successful in 469 (99.8%). The push technique was utilized in 209 patients, reduction in the bolus size by piecemeal removal followed by the push technique was utilized in 97 patients, and the pull technique was utilized in 107 patients. There were no perforations with endoscopic removal. Only 4.5% of the X-rays performed reported a possible foreign body within the esophagus. Glucagon was a significantly less-expensive strategy than endoscopic therapy (p < 0.0001). Glucagon is low cost, is moderately effective, and may be considered as an initial strategy. Endoscopic removal regardless of technique is safe and effective. The yield of radiography is poor in the setting of food bolus impaction.
Long, Bibo; Ye, Binhui; Liu, Qinglin; Zhang, Shu; Ye, Jien; Zou, Lina
2018-01-01
Removal of toxic Cr(VI) by microbial reduction is a promising approach to reducing its ecotoxicological impact. To develop bioremediation technologies, many studies have evaluated the application of microorganisms isolated from Cr(VI)-contaminated sites. Nonetheless, little attention has been given to microbes from the environments without a history of Cr(VI) contamination. In this study, we aimed to characterize the Cr(VI) tolerance and removal abilities of a filamentous fungus strain, SL2, isolated from indoor air. Based on phenotypic characterization and rDNA sequence analysis, SL2 was identified as Penicillium oxalicum, a species that has not been extensively studied regarding Cr(VI) tolerance and reduction abilities. SL2 showed high tolerance to Cr(VI) on solid and in liquid media, facilitating its application to Cr(VI)-contaminated environments. Growth curves of SL2 in the presence of 0, 100, 400, or 1000 mg/L Cr(VI) were well simulated by the modified Gompertz model. The relative maximal colony diameter and maximal growth rate decreased as Cr(VI) concentration increased, while the lag time increased. SL2 manifested remarkable efficacy of removing Cr(VI). Mass balance analysis indicated that SL2 removed Cr(VI) by reduction, and incorporated 0.79 mg of Cr per gram of dry biomass. In electroplating wastewater, the initial rate of Cr(VI) removal was affected by the initial contaminant concentration. In conclusion, P. oxalicum SL2 represents a promising new candidate for Cr(VI) removal. Our results significantly expand the knowledge on potential application of this microorganism. PMID:29381723
Zahed, Mohammad Ali; Aziz, Hamidi Abdul; Isa, Mohamed Hasnain; Mohajeri, Leila
2010-04-01
The effects of initial oil concentration and the Corexit 9500 dispersant on the rate of bioremediation of petroleum hydrocarbons were investigated with a series of ex-situ seawater samples. With initial oil concentrations of 100, 500, 1,000 and 2,000 mg/L, removal of total petroleum hydrocarbons (TPHs) with dispersant were 67.3%, 62.5%, 56.5% and 44.7%, respectively, and were 64.2%, 55.7%, 48.8% and 37.6% without dispersant. The results clearly indicate that the presence of dispersant enhanced crude oil biodegradation. Lower concentrations of crude oil demonstrated more efficient hydrocarbon removal. Based on these findings, bioremediation is not recommended for crude oil concentrations of 2,000 mg/L or higher.
John M. Kabrick; Benjamin O. Knapp; Daniel C. Dey; David R. Larsen
2015-01-01
There is interest in restoring shortleaf pine (Pinus echinata) in pineâoak woodlands where it once was abundant. Because of its shade intolerance and slow initial growth rate, shortleaf pine restoration has remained a challenge because competition from hardwoods exhibits greater initial growth following canopy removal but greater shade tolerance with...
Deng, Yang; Englehardt, James D
2009-09-30
A hydrogen peroxide (H(2)O(2))-enhanced iron (Fe(0))-mediated aeration (IMA) process has been recently demonstrated to effectively remove organic wastes from mature landfill leachate. In this paper, the kinetics and oxidative mechanisms of the enhanced IMA treatment were studied. Bench-scale full factorial tests were conducted in an orbital shaker reactor for treatment of a mature leachate with an initial chemical oxygen demand (COD) of 900-1200 mg/L. At the maximum aeration rate (8.3 mL air/min mL sample), process variables significantly influencing the rates of H(2)O(2) decay and COD removal were pH (3.0-8.0), initial H(2)O(2) doses (0.21-0.84 M), and Fe(0) surface area concentrations (0.06-0.30 m(2)/L). Empirical kinetic models were developed and verified for the degradation of H(2)O(2) and COD. High DO maintained by a high aeration rate slowed the H(2)O(2) self-decomposition, accelerated Fe(0) consumption, and enhanced the COD removal. In hydroxyl radical (OH*) scavenging tests, the rate of removal of glyoxylic acid (target compound) was not inhibited by the addition of para-chlorobenzoic acid (OH* scavenger) at pH 7.0-7.5, ruling out hydroxyl radical as the principal oxidant in neutral-weakly basic solution. These experimental results show that this enhanced IMA technology is a potential alternative for the treatment of high strength recalcitrant organic wastewaters.
Jafari, Maryam; Rahimi, Mahmood Reza; Ghaedi, Mehrorang; Javadian, Hamedreza; Asfaram, Arash
2017-12-01
A continuous adsorption was used for removal of azure II (AZ II) and auramine O (AO) from aqueous solutions using Pinus eldarica stalks activated carbon (PES-AC) from aqueous solutions. The effects of initial dye concentration, flow rate, bed height and contact time on removal percentage of AO and AZ II were evaluated and optimized by central composite design (CCD) at optimum pH = 7.0. ZnO nanoparticles loaded on activated carbon were also used to remove AO and AZ II at pH = 7.0 and other optimum conditions. The breakthrough curves were obtained at different flow rates, initial dye concentrations and bed heights and the experimental data were fitted by Thomas, Adams-Bohart and Yoon-Nelson models. The main parameters of fixed-bed column including its adsorption capacity at breakthrough point (q b ), adsorption capacity at saturation point (q s ), mass transfer zone (MTZ), total removal percentage (R%), and empty bed contact time (EBCT) were calculated. The removal percentages calculated for AZ II and AO II were in the range of 51.6-61.1% and 40.6-61.6%, respectively. Bed adsorption capacity (N 0 ) and critical bed depth (Z 0 ) were obtained by BDST model. Copyright © 2017 Elsevier Inc. All rights reserved.
High-resolution experiments on chemical oxidation of DNAPL in variable-aperture fractures
NASA Astrophysics Data System (ADS)
Arshadi, Masoud; Rajaram, Harihar; Detwiler, Russell L.; Jones, Trevor
2015-04-01
Chemical oxidation of dense nonaqueous-phase liquids (DNAPLs) by permanganate has emerged as an effective remediation strategy in fractured rock. We present high-resolution experimental investigations in transparent analog variable-aperture fractures to improve understanding of chemical oxidation of residual entrapped trichloroethylene (TCE) in fractures. Four experiments were performed with different permanganate concentrations, flow rates, and initial TCE phase geometry. The initial aperture field and evolving entrapped-phase geometry were quantified for each experiment. The integrated mass transfer rate from the TCE phase for all experiments exhibited three time regimes: an early-time regime with slower mass transfer rates limited by low specific interfacial area; an intermediate-time regime with higher mass transfer rates resulting from breakup of large TCE blobs, which greatly increases specific interfacial area; and a late-time regime with low mass transfer rates due to the deposition of MnO2 precipitates. In two experiments, mass balance analyses suggested that TCE mass removal rates exceeded the maximum upper bound mass removal rates derived by assuming that oxidation and dissolution are the only mechanisms for TCE mass removal. We propose incomplete oxidation by permanganate and TCE solubility enhancement by intermediate reaction products as potential mechanisms to explain this behavior. We also speculate that some intermediate reaction products with surfactant-like properties may play a role in lowering the TCE-water interfacial tension, thus causing breakup of large TCE blobs. Our quantitative experimental measurements will be useful in the context of developing accurate computational models for chemical oxidation of TCE in fractures.
Gentle, M J; Hunter, L N
1991-01-01
Electroencephalographic, cardiovascular and behavioural parameters were examined in Gallus gallus var domesticus in response to feather removal. The progressive removal of feathers resulted in marked changes in the bird's behaviour from an alert agitated response following the initial removals to periods of crouching immobility following successive removals. During the periods of immobility the birds showed a high amplitude low frequency EEG pattern and successive removals resulted in a progressive increase in the total duration of this activity in the two minutes after removal. The heart rate response to feather removal was variable whereas the blood pressure always increased and this increase was followed by a gradual return to pre-stimulus levels. There were no consistent cardiovascular responses related to the immobility. It was concluded that feather removal is likely to be painful to the bird and feather removal by flockmates can be categorised as a welfare problem.
Use of drinking water treatment solids for arsenate removal from desalination concentrate.
Xu, Xuesong; Lin, Lu; Papelis, Charalambos; Myint, Maung; Cath, Tzahi Y; Xu, Pei
2015-05-01
Desalination of impaired water can be hindered by the limited options for concentrate disposal. Selective removal of specific contaminants using inexpensive adsorbents is an attractive option to address the challenges of concentrate management. In this study, two types of ferric-based drinking water treatment solids (DWTS) were examined for arsenate removal from reverse osmosis concentrate during continuous-flow once-through column experiments. Arsenate sorption was investigated under different operating conditions including pH, arsenate concentration, hydraulic retention time, loading rate, temperature, and moisture content of the DWTS. Arsenate removal by the DWTS was affected primarily by surface complexation, electrostatic interactions, and arsenate speciation. Results indicated that arsenate sorption was highly dependent on initial pH and initial arsenate concentration. Acidic conditions enhanced arsenate sorption as a result of weaker electrostatic repulsion between predominantly monovalent H2AsO4(-) and negatively charged particles in the DWTS. High initial arsenate concentration increased the driving force for arsenate sorption to the DWTS surface. Tests revealed that the potential risks associated with the use of DWTS include the leaching of organic contaminants and ammonia, which can be alleviated by using wet DWTS or discarding the initially treated effluent that contains high organic concentration. Copyright © 2015 Elsevier Inc. All rights reserved.
Cohoon, Kevin P; McBride, Joseph; Friese, Jeremy L; McPhail, Ian R
2015-10-01
Evaluate the success rate of retrievable inferior vena cava filter (IVC) removal in a tertiary care practice. Retrievable IVC filters became readily available in the United States following Food and Drug Administration approval in 2003, and their use has increased dramatically. They represent an attractive option for patients with contraindications to anticoagulation who may only need short-term protection against pulmonary embolism. All patients who had undergone placement of a retrievable IVC filter at Mayo Clinic between 2003 and 2005 were retrospectively reviewed to evaluate our initial experience with retrievable inferior vena cava filters at a large tertiary care center. During a three-year-period of time, Mayo Clinic, Rochester, MN placed 892 IVC filters of which 460 were retrievable. Of the 460 retrievable filters placed (249 Günther Tulip®, 207 Recovery®, and 4 OptEase®), retrieval was attempted in 223 (48.5%). Of 223 initial attempts, 196 (87.9%) were initially successful and 27 (12.1%) were unsuccessful. Of the 27 unsuccessful initial retrieval attempts, 23 (85.2%) were because of the presence of significant thrombus within the filter and 4 (14.8%) were because of tilting and strut perforation. Of the 23 filters containing significant thrombus, 9 (39.1%) were later retrieved after a period of anticoagulation and resolution of the thrombus. Retrievable IVC filters can be removed with a high degree of success. Approximately one in ten retrievable IVC filter removal attempts may fail initially, usually because of significant thrombus within the filter. This does not preclude possible removal at a later date. © 2015 Wiley Periodicals, Inc.
Evolution of the chemistry of Fe bearing waters during CO2 degassing
Geroni, J.N.; Cravotta, C.A.; Sapsford, D.J.
2012-01-01
The rates of Fe(II) oxidation and precipitation from groundwater are highly pH dependent. Elevated levels of dissolved CO2 can depress pH and cause difficulty in removing dissolved Fe and associated metals during treatment of ferruginous water. This paper demonstrates interdependent changes in pH, dissolved inorganic C species, and Fe(II) oxidation rates that occur as a result of the removal (degassing) of CO2 during aeration of waters discharged from abandoned coal mines. The results of field monitoring of aeration cascades at a treatment facility as well as batchwise aeration experiments conducted using net alkaline and net acidic waters in the UK are combined with geochemical modelling to demonstrate the spatial and temporal evolution of the discharge water chemistry. The aeration cascades removed approximately 67% of the dissolved CO2 initially present but varying the design did not affect the concentration of Fe(II) leaving the treatment ponds. Continued removal of the residual CO2 by mechanical aeration increased pH by as much as 2 units and resulted in large increases in the rates of Fe(II) oxidation and precipitation. Effective exsolution of CO2 led to a reduction in the required lime dose for removal of remaining Fe(II), a very important factor with regard to increasing the sustainability of treatment practices. An important ancillary finding for passive treatment is that varying the design of the cascades had little impact on the rate of CO2 removal at the flow rates measured.
Kakkos, A; Bresson, L; Hudry, D; Cousin, S; Lervat, C; Bogart, E; Meurant, J P; El Bedoui, S; Decanter, G; Hannebicque, K; Regis, C; Hamdani, A; Penel, N; Tresch-Bruneel, E; Narducci, F
2017-04-01
Totally implantable venous access port systems are widely used in oncology, with frequent complications that sometimes necessitate device removal. The aim of this study is to investigate the impact of the time interval between port placement and initiation of chemotherapy and the neutropenia-inducing potential of the chemotherapy administered upon complication-related port removal. Between January 2010 and December 2013, 4045 consecutive patients were included in this observational, single-center prospective study. The chemotherapy regimens were classified as having a low (<10%), intermediate (10-20%), or high (>20%) risk for inducing neutropenia. The overall removal rate due to complications was 7.2%. Among them, port-related infection (2.5%) and port expulsion (1%) were the most frequent. The interval between port insertion and its first use was shown to be a predictive factor for complication-related removal rates. A cut-off of 6 days was statistically significant (p = 0.008), as the removal rate for complications was 9.4% when this interval was 0-5 days and 5.7% when it was ≥6 days. Another factor associated with port complication rate was the neutropenia-inducing potential of the chemotherapy regimens used, with removal for complications involved in 5.5% of low-risk regimens versus 9.4% for the intermediate- and high-risk regimens (p = 0.003). An interval of 6 days between placement and first use of the port reduces the removal rate from complications. The intermediate- and high-risk for neutropenia chemotherapy regimens are related to higher port removal rates from complications than low-risk regimens. Copyright © 2016 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.
Kocamemi, B Alpaslan; Ceçen, F
2010-01-01
In the present study, cometabolic TCE degradation was evaluated using NH(4)-N as the growth-substrate. At initial TCE concentrations up to 845 microg/L, TCE degradation followed first-order kinetics. The increase in ammonium utilization rate favored the degradation of TCE. This ensured that biological transformation of TCE in nitrifying systems is accomplished through a cometabolic pathway by the catalysis of non-specific ammonia oxygenase enzyme of nitrifiers. The transformation yield (T(y)) of TCE, the amount of TCE degraded per unit mass of NH(4)-N, strongly depended on the initial NH(4)-N and TCE concentrations. In order to allow a rough estimation of TCE removal and nitrification at different influent TCE and NH(4)-N concentrations, a linear relationship was developed between 1/T(y) and the initial NH(4)-N/TCE ratio. The estimated T(y) values lead to the conclusion that nitrifying systems are promising candidates for biological removal of TCE through cometabolism.
Preliminary development and evaluation of an algae-based air regeneration system
NASA Technical Reports Server (NTRS)
Nienow, J. A.
2000-01-01
The potential of air regeneration system based on the growth of microalgae on the surface of porous ceramic tubes is evaluated. The algae have been maintained in the system for extended periods, up to 360 days. Preliminary measurements of the photosynthetic capacity have been made for Chlorella vulgaris (UTEX 259), Neospongiococcum punctatum (UTEX 786), Stichococcus sp., and Gloeocapsa sp. Under standard test conditions (photosynthetic photon flux approximately 66 micromoles m-2 s-1, initial CO2 concentration approximately 450 micromoles mol-1), mature tubes remove up to 0.2 micromoles of CO2 per tube per minute. The rate of removal increases with photon flux up to at least 225 micromoles m-2 s-1 (PPF); peak rates of 0.35 micromoles of CO2 per tube per minute have been achieved with Chlorella vulgaris. These rates correspond to between 120 and 210 micromoles of CO2 removed per square meter of projected area per minute.
Decomposition of dimethylamine gas with dielectric barrier discharge.
Ye, Zhaolian; Zhao, Jie; Huang, Hong ying; Ma, Fei; Zhang, Renxi
2013-09-15
The decomposition of dimethylamine (DMA) with gas under high flow rate was investigated with dielectric barrier discharge (DBD) technology. Different parameters including removal efficiency, energy yield, carbon balance and CO2 selectivity, secondary products, as well as pathways and mechanisms of DMA degradation were studied. The experimental results showed that removal efficiency of DMA depended on applied voltage and gas flow rate, but had no obvious correlation with initial concentration. Excellent energy performance was obtained using present DBD technology for DMA abatement. When experiment conditions were controlled at: gas flow rate of 14.9 m(3)/h, initial concentration of 2104 mg/m(3), applied voltage of 4.8 kV, removal efficiency of DMA and energy yield can reach 85.2% and 953.9 g/kWh, respectively. However, carbon balance (around 40%) was not ideal due to shorter residence time (about 0.1s), implying that some additional conditions should be considered to improve the total oxidation of DMA. Moreover, secondary products in outlet gas stream were detected via gas chromatogram-mass spectrum and the amounts of NO3(-) and NO2(-) were analyzed by ion chromatogram. The obtained data demonstrated that NOx might be suppressed due to reductive NH radical form DMA dissociation. The likely reaction pathways and mechanisms for the removal of DMA were suggested based on products analysis. Experimental results demonstrated the application potential of DBD as a clean technology for organic nitrogen-containing gas elimination from gas streams. Copyright © 2013 Elsevier B.V. All rights reserved.
Degassing Lakes Nyos and Monoun: Defusing certain disaster
Kling, G.W.; Evans, William C.; Tanyileke, G.; Kusakabe, M.; Ohba, T.; Yoshida, Y.; Hell, J.V.
2005-01-01
Since the catastrophic releases of CO2 in the 1980s, Lakes Nyos and Monoun in Cameroon experienced CO2 recharge at alarming rates of up to 80 mol/m2 per yr. Total gas pressures reached 8.3 and 15.6 bar in Monoun (2003) and Nyos (2001), respectively, resulting in gas saturation levels up to 97%. These natural hazards are distinguished by the potential for mitigation to prevent future disasters. Controlled degassing was initiated at Nyos (2001) and Monoun (2003) amid speculation it could inadvertently destabilize the lakes and trigger another gas burst. Our measurements indicate that water column structure has not been compromised by the degassing and local stability is increasing in the zones of degassing. Furthermore, gas content has been reduced in the lakes ???12-14%. However, as gas is removed, the pressure at pipe inlets is reduced, and the removal rate will decrease over time. Based on 12 years of limnological measurements we developed a model of future removal rates and gas inventory, which predicts that in Monoun the current pipe will remove ???30% of the gas remaining before the natural gas recharge balances the removal rate. In Nyos the single pipe will remove ???25% of the gas remaining by 2015; this slow removal extends the present risk to local populations. More pipes and continued vigilance are required to reduce the risk of repeat disasters. Our model indicates that 75-99% of the gas remaining would be removed by 2010 with two pipes in Monoun and five pipes in Nyos, substantially reducing the risks. ?? 2005 by The National Academy of Sciences of the USA.
Research of combined adsorption-coagulation process in treating petroleum refinery effluent.
Wang, Bing; Shui, Yiyu; Ren, Hongyang; He, Min
2017-02-01
The petroleum refinery industry generates a significant amount of wastewater that contains a high level of organic matter, which calls for effective and costly treatments. In this research, the effectiveness of the petroleum refinery effluent (PRE) treatment with physicochemical process of combined adsorption and coagulation was evaluated. The effects of initial pH, hydraulic condition , and combined sequence of treatment process, different treating reagent types and dosages on the chemical oxygen demand (COD) removal were investigated. Additionally, the elimination efficiency of pollutant wastewater was monitored by gas chromatography-mass spectrometry (GC-MS), and Fourier transformed infrared (FT-IR) spectrophotometer was adopted to describe the structure of the wastewater. Wooden activated carbon was chosen as adsorbent at the dosage of 10 g/L as a primary treatment, and 1500 mg/L polymeric magnesium ferric sulfate was used in coagulation. Results showed that adsorption and subsequent coagulation displayed the best performance when initial pH was 9 at shear rates (G) of G1 = 65 s -1 and G2 = 20 s -1 , which reached maximal removal rate of COD and total organic carbon GC-MS testing result revealed that adsorption was effective in phenols and iso-alkanes removal, whereas coagulation was good at removing esters and n-alkanes.
Sun, Yongjun; Zhu, Chengyu; Sun, Wenquan; Xu, Yanhua; Xiao, Xuefeng; Zheng, Huaili; Wu, Huifang; Liu, Cuiyun
2017-05-15
In this work, a highly efficient and environmentally friendly chitosan-based graft flocculant, namely, acrylamide- and dimethyl diallyl ammonium chloride-grafted chitosan [CS-g-P(AM-DMDAAC)], was prepared successfully through plasma initiation. FTIR results confirmed the successful polymerization of CS-g-P(AM-DMDAAC) and P(AM-DMDAAC). P(AM-DMDAAC) was the copolymer of acrylamide- and dimethyl diallyl ammonium chloride. SEM results revealed that a densely cross-linked network structure formed on the surface. XRD results verified that the ordered crystal structure of chitosan in CS-g-P(AM-DMDAAC) was changed into an amorphous structure after plasma-induced polymerization. The flocculation results of low-algal-turbidity water further showed the optimal flocculation efficiency of turbidity removal rate, COD removal rate, and Chl-a removal rate were 99.02%, 96.11%, and 92.20%, respectively. The flocculation efficiency of CS-g-P(AM-DMDAAC) were significantly higher than those obtained by cationic polyacrylamide (CPAM) and Polymeric aluminum and iron (PAFC). This work provided a valuable basis for the design of eco-friendly naturally modified polymeric flocculants to enhance the flocculation of low-algal-turbidity water. Copyright © 2017 Elsevier Ltd. All rights reserved.
Managing the Cayo Santiago rhesus macaque population: The role of density.
Hernandez-Pacheco, Raisa; Delgado, Diana L; Rawlins, Richard G; Kessler, Matthew J; Ruiz-Lambides, Angelina V; Maldonado, Elizabeth; Sabat, Alberto M
2016-01-01
Cayo Santiago is the oldest continuously operating free-ranging rhesus monkey colony in the world. Population control of this colony has historically been carried out by periodic live capture and removal of animals. However, the effect of such a strategy on the size, growth rate, age structure, and sex ratio of the population has not been analyzed. This study reviews past removal data and uses a population projection model to simulate the effects of different removal schemes based on Cayo Santiago demographic data from 2000-2012. The model incorporates negative density-dependence in female fertility, as well as male and female survival rates, to determine the population-level effects of selective removal by age and sex. Modeling revealed that removal of sexually immature individuals has negligible effects on the population dynamics explaining why with an initial population of 1309 in 2000 and annual removals of immature monkeys a mean annual population growth rate of 12% and a final population size of ∼1,435 individuals by 2012 (∼0.009 animal/m(2) ) was observed. With no removals, the population is expected to exhibit dampened oscillations until reaching equilibrium at ∼1,690 individuals (∼0.0111 animal/m(2) ) in 2,100. In contrast, removal of adult females (≥4 yrs) would significantly reduce the population size, but would also promote an increase in population growth rate due to density feedback. A maximum annual production of 275 births is expected when 550 adult females are present in the population. Sensitivity analyses showed that removing females, in contrast to controlling their fertility through invasive treatments would contribute the most to changes in population growth rate. Given the density compensation on fertility, stabilizing the population would require removing ∼80% of the current population of adult females. This study highlights the importance of addressing the population-level density effects, as well as sensitivity analyses, to optimize management strategies. © 2016 Wiley Periodicals, Inc.
Horemans, Benjamin; Raes, Bart; Vandermaesen, Johanna; Simanjuntak, Yanti; Brocatus, Hannelore; T'Syen, Jeroen; Degryse, Julie; Boonen, Jos; Wittebol, Janneke; Lapanje, Ales; Sørensen, Sebastian R; Springael, Dirk
2017-02-07
Aminobacter sp. MSH1 immobilized in an alginate matrix in porous stones was tested in a pilot system as an alternative inoculation strategy to the use of free suspended cells for biological removal of micropollutant concentrations of 2,6-dichlorobenzamide (BAM) in drinking water treatment plants (DWTPs). BAM removal rates and MSH1 cell numbers were recorded during operation and assessed with specific BAM degradation rates obtained in lab conditions using either freshly grown cells or starved cells to explain reactor performance. Both reactors inoculated with either suspended or immobilized cells showed immediate BAM removal under the threshold of 0.1 μg/L, but the duration of sufficient BAM removal was 2-fold (44 days) longer for immobilized cells. The longer sufficient BAM removal in case of immobilized cells compared to suspended cells was mainly explained by a lower initial loss of MSH1 cells at operational start due to volume replacement and shear. Overall loss of activity in the reactors though was due to starvation, and final removal rates did not differ between reactors inoculated with immobilized and suspended cells. Management of assimilable organic carbon, in addition to cell immobilization, appears crucial for guaranteeing long-term BAM degradation activity of MSH1 in DWTP units.
Removal of heavy metal from industrial effluents using Baker's yeast
NASA Astrophysics Data System (ADS)
Ferdous, Anika; Maisha, Nuzhat; Sultana, Nayer; Ahmed, Shoeb
2016-07-01
Bioremediation of wastewater containing heavy metals is one of the major challenges in environmental biotechnology. Heavy metals are not degraded and as a result they remain in the ecosystem, and pose serious health hazards as it comes in contact with human due to anthropogenic activities. Biological treatment with various microorganisms has been practiced widely in recent past, however, accessing and maintaining the microorganisms have always been a challenge. Microorganisms like Baker's yeast can be very promising biosorbents as they offer high surface to volume ratio, large availability, rapid kinetics of adsorption and desorption and low cost. The main aim of this study is to evaluate the applicability of the biosorption process using baker's yeast. Here we present an experimental investigation of biosorption of Chromium (Cr) from water using commercial Baker's Yeast. It was envisaged that yeast, dead or alive, would adsorb heavy metals, however, operating parameters could play vital roles in determining the removal efficiency. Parameters, such as incubation time, pH, amount of biosorbent and heavy metal concentration were varied to investigate the impacts of those parameters on removal efficiency. Rate of removal was found to be inversely proportional to the initial Cr (+6) concentrations but the removal rate per unit biomass was a weakly dependent on initial Cr(+6) concentrations. Biosorption process was found to be more efficient at lower pH and it exhibited lower removal with the increase in solution pH. The optimum incubation time was found to be between 6-8 hours and optimum pH for the metal ion solution was 2. The effluents produced in leather industries are the major source of chromium pollution in Bangladesh and this study has presented a very cost effective yet efficient heavy metal removal approach that can be adopted for such kind of wastewater.
Kazemipour, Maryam; Ansari, Mehdi; Tajrobehkar, Shabnam; Majdzadeh, Majdeh; Kermani, Hamed Reihani
2008-01-31
In this work, adsorption of copper (Cu), zinc (Zn), lead (Pb), and cadmium (Cd) that exist in industrial wastewater onto the carbon produced from nutshells of walnut, hazelnut, pistachio, almond, and apricot stone has been investigated. All the agricultural shell or stone used were ground, sieved to a defined size range, and carbonized in an oven. Time and temperature of heating were optimized at 15 min and 800 degrees C, respectively, to reach maximum removal efficiency. Removal efficiency was optimized regarding to the initial pH, flow rate, and dose of adsorbent. The maximum removal occurred at pH 6-10, flow rate of 3 mL/min, and 0.1g of the adsorbent. Capacity of carbon sources for removing cations will be considerably decreased in the following times of passing through them. Results showed that the cations studied significantly can be removed by the carbon sources. Efficiency of carbon to remove the cations from real wastewater produced by copper industries was also studied. Finding showed that not only these cations can be removed considerably by the carbon sources noted above, but also removing efficiency are much more in the real samples. These results were in adoption to those obtained by standard mixture synthetic wastewater.
Kabdaşli, Işik; Keleş, Asuman; Olmez-Hanci, Tuğba; Tünay, Olcay; Arslan-Alaton, Idil
2009-11-15
In this study, treatment of phthalates by electrocoagulation employing stainless steel electrodes was investigated using dimethyl phthalate (DMP) as a model compound. DMP was completely destructed within 30 min up to the high initial concentration of 100mg/L while total mineralization was also obtained within a couple of hours. The applied current density of 22.5 mA/cm(2) and electrolyte (NaCl) concentrations varying between 1000 and 1500 mg/L as chloride resulted in the highest treatment performance. The initial solution pH (2-6) had practically no effect on the process efficiency. Desorption experiments and the reaction rates obtained for DMP, COD and TOC abatements appeared to be a strong evidence of an oxidative removal mechanism. DMP removal fitted first order kinetics. COD and TOC removals began after the total DMP removal and also fitted first order kinetics. Activated sludge inhibition experiments revealed that toxicity could be significantly reduced by electrocoagulation application.
Preparation of carbon coated Fe3O4 nanoparticles for magnetic separation of uranium
NASA Astrophysics Data System (ADS)
Zhang, Xiaofei; Wang, Jun
2018-01-01
Uranium(VI) was removed from aqueous solutions using carbon coated Fe3O4 nanoparticles (Fe3O4@C). Batch experiments were conducted to study the effects of initial pH, shaking time and temperature on uranium sorption efficiency. It was found that the maximum adsorption capacity of the Fe3O4@C toward uranium(VI) was ∼120.20 mg g-1 when the initial uranium(VI) concentration was 100 mg L-1, displaying a high efficiency for the removal of uranium(VI) ions. Kinetics of the uranium(VI) removal is found to follow pseudo-second-order rate equation. In addition, the uranium(VI)-loaded Fe3O4@C nanoparticles can be recovered easily from aqueous solution by magnetic separation and regenerated by acid treatment. Present study suggested that magnetic Fe3O4@C composite particles can be used as an effective and recyclable adsorbent for the removal of uranium(VI) from aqueous solutions.
Plasma cleaning of beamline optical components: Contamination and gas composition effects
NASA Astrophysics Data System (ADS)
Rosenberg, Richard A.; Smith, James A.; Wallace, Daniel J.
1992-01-01
We have initiated a program to study the impact of gas composition on the carbon removal rate during plasma cleaning of optical components, and of possible contamination due to the plasma processing. The measurements were performed in a test chamber designed to simulate the geometry of the grating/Codling mirror section of a Grasshopper monochromator. Removal rates were determined for a direct-current (dc) (Al electrode) discharge using a quartz crystal microbalance coated with polymethylmethacrylate, located at the position of the grating. Auger electron spectroscopy analysis of strateg- ically located, gold-coated stainless steel samples was employed to determine contamination. The relative removal rates of the gases studied were 3% C2F6/O2≫ O2+H2O≳O2˜N2O≳H2≳N2. Although the C2F6/O2 gas mixture showed a 20 times greater removal rate than its nearest competitor, it also caused significant contamination to occur. Contamination studies were performed for both dc and radio-frequency (rf) discharges. For the dc discharge we found that great care must be taken in order to avoid Al contamination; for the rf discharge, significant Fe contamination was observed.
Removal of cadmium from aqueous solutions using industrial coal fly ash-nZVI.
Ma, Lixia; Wei, Qi; Chen, Yueqin; Song, Qiuyang; Sun, Conghui; Wang, Zhiqiang; Wu, Guanghong
2018-02-01
Batch experiments were conducted to test the effects of various solution properties, such as pH, temperature, initial concentration and anoxic and aerobic atmosphere, on Cd removal by nanoscale zerovalent iron (nZVI) supported on industrial coal fly ash. Cd (II) could be removed by adsorption on fly ash-nZVI in a very short time (5 min) with high removal rates (greater than 99.9%) over a wide range of concentration (5-100 mg l -1 ). Cd (II) was physically adsorbed on the surface of fly ash-nZVI. The preparation of fly ash-nZVI can incorporate the use of waste media, making the overall adsorbent more removal efficient and low cost.
Removal of cadmium from aqueous solutions using industrial coal fly ash-nZVI
Ma, Lixia; Wei, Qi; Chen, Yueqin; Song, Qiuyang; Sun, Conghui; Wang, Zhiqiang
2018-01-01
Batch experiments were conducted to test the effects of various solution properties, such as pH, temperature, initial concentration and anoxic and aerobic atmosphere, on Cd removal by nanoscale zerovalent iron (nZVI) supported on industrial coal fly ash. Cd (II) could be removed by adsorption on fly ash-nZVI in a very short time (5 min) with high removal rates (greater than 99.9%) over a wide range of concentration (5–100 mg l−1). Cd (II) was physically adsorbed on the surface of fly ash-nZVI. The preparation of fly ash-nZVI can incorporate the use of waste media, making the overall adsorbent more removal efficient and low cost. PMID:29515830
Optimizing photo-Fenton like process for the removal of diesel fuel from the aqueous phase
2014-01-01
Background In recent years, pollution of soil and groundwater caused by fuel leakage from old underground storage tanks, oil extraction process, refineries, fuel distribution terminals, improper disposal and also spills during transferring has been reported. Diesel fuel has created many problems for water resources. The main objectives of this research were focused on assessing the feasibility of using photo-Fenton like method using nano zero-valent iron (nZVI/UV/H2O2) in removing total petroleum hydrocarbons (TPH) and determining the optimal conditions using Taguchi method. Results The influence of different parameters including the initial concentration of TPH (0.1-1 mg/L), H2O2 concentration (5-20 mmole/L), nZVI concentration (10-100 mg/L), pH (3-9), and reaction time (15-120 min) on TPH reduction rate in diesel fuel were investigated. The variance analysis suggests that the optimal conditions for TPH reduction rate from diesel fuel in the aqueous phase are as follows: the initial TPH concentration equals to 0.7 mg/L, nZVI concentration 20 mg/L, H2O2 concentration equals to 5 mmol/L, pH 3, and the reaction time of 60 min and degree of significance for the study parameters are 7.643, 9.33, 13.318, 15.185 and 6.588%, respectively. The predicted removal rate in the optimal conditions was 95.8% and confirmed by data obtained in this study which was between 95-100%. Conclusion In conclusion, photo-Fenton like process using nZVI process may enhance the rate of diesel degradation in polluted water and could be used as a pretreatment step for the biological removal of TPH from diesel fuel in the aqueous phase. PMID:24955242
Das, Dipa; Samal, Debi Prasad; Meikap, Bhim C
2016-07-28
To mitigate the emission of carbon dioxide (CO2), we have developed and designed a four-stage fluidized bed reactor. There is a counter current exchange between solid adsorbent and gas flow. In this present investigation diethanol amine (DEA) impregnated activated carbon made from green coconut shell was used as adsorbent. This type of adsorbent not only adsorbs CO2 due to the presence of pore but also chemically reacts with CO2 and form secondary zwitterions. Sampling and analysis of CO2 was performed using Orsat apparatus. The effect of initial CO2 concentration, gas velocity, solid rate, weir height etc. on removal efficiency of CO2 have been investigated and presented. The percentage removal of CO2 has been found close to 80% under low gas flow rate (0.188 m/s), high solid flow rate (4.12 kg/h) and weir height of 50 mm. From this result it has been found out that multistage fluidized bed reactor may be a suitable equipment for removal of CO2 from flue gas.
Fernandes, Annabel; Labiadh, Lazhar; Ciríaco, Lurdes; Pacheco, Maria José; Gadri, Abdellatif; Ammar, Salah; Lopes, Ana
2017-10-01
The electro-Fenton oxidation of a concentrate from reverse osmosis of a sanitary landfill leachate, with an initial chemical oxygen demand (COD) of 42 g L -1 , was carried out using a carbon-felt cathode and a boron doped diamond anode. The influence of the applied current intensity, initial pH and dissolved iron initial concentration on the electro-Fenton process was assessed. For the experimental conditions used, results showed that the initial pH is the parameter that more strongly influences the current efficiency of the electro-Fenton process, being this influence more pronounced on the oxidation rate than on the mineralization rate of the organic matter. The increase in iron initial concentration was found to be detrimental, since the natural amount of iron present in the effluent, 73 mg L -1 of total iron and 61 mg L -1 of dissolved iron, was sufficient to ensure the electro-Fenton process at the applied intensities - 0.2-1.4 A. For the more favourable conditions studied, initial pH of 3 and natural iron concentration, it was found an increase in the organic load and nitrogen removals with the applied current intensity. For the highest current intensity applied, a COD removal of 16.7 g L -1 was achieved after 8-h experiments. Copyright © 2017 Elsevier Ltd. All rights reserved.
Polishing of anaerobic secondary effluent by Chlorella vulgaris under low light intensity.
Cheng, Tuoyuan; Wei, Chun-Hai; Leiknes, TorOve
2017-10-01
To investigate anaerobic secondary effluent polishing by microalgae (Chlorella vulgaris) under low light intensity (14μmol/m 2 /s), bubbling column reactors were operated in batches of 8 d with initial ammonium nitrogen 10-50mg/L, initial phosphate phosphorus 2-10mg/L and microalgal seed 40mg/L. Maximum microalgal biomass and minimum generation time were 370.9mg/L and 2.5d, respectively. Nitrogen removal (maximum 99.6%) was mainly attributed to microalgal growth rate, while phosphorus removal (maximum 49.8%) was related to microalgal growth rate, cell phosphorus content (maximum 1.5%) and initial nutrients ratio. Dissolved microalgal organics release in terms of chemical oxygen demand (maximum 63.2mg/L) and hexane extractable material (i.e., oil and grease, maximum 8.5mg/L) was firstly reported and mainly affected by nitrogen deficiency and deteriorated effluent quality. Ultrafiltration critical flux (16.6-39.5L/m 2 /h) showed negative linear correlation to microalgal biomass. Anaerobic membrane bioreactor effluent polishing showed similar results with slight inhibition to synthetic effluent. Copyright © 2017 Elsevier Ltd. All rights reserved.
Bryant, F O; Hale, D D; Rogers, J E
1991-01-01
The reductive dechlorination of pentachlorophenol (PCP) was investigated in anaerobic sediments that contained nonadapted or 2,4- or 3,4-dichlorophenol (DCP)-adapted microbial communities. Adaptation of sediment communities increased the rate of conversion of 2,4- or 3,4-DCP to monochlorophenols (CPs) and eliminated the lag phase before dechlorination was observed. Both 2,4- and 3,4-DCP-adapted sediment communities dechlorinated the six DCP isomers to CPs. The specificity of chlorine removal from the DCP isomers indicated a preference for ortho-chlorine removal by 2,4-DCP-adapted sediment communities and for para-chlorine removal by 3,4-DCP-adapted sediment communities. Sediment slurries containing nonadapted microbial communities either did not dechlorinate PCP or did so following a lag phase of at least 40 days. Sediment communities adapted to dechlorinate 2,4- or 3,4-DCP dechlorinated PCP without an initial lag phase. The 2,4-DCP-adapted communities initially removed the ortho-chlorine from PCP, whereas the 3,4-DCP-adapted communities initially removed the para-chlorine from PCP. A 1:1 mixture of the adapted sediment communities also dechlorinated PCP without a lag phase. Dechlorination by the mixture was regiospecific, following a para greater than ortho greater than meta order of chlorine removal. Intermediate products of degradation, 2,3,5,6-tetrachlorophenol, 2,3,5-trichlorophenol, 3,5-DCP, 3-CP, and phenol, were identified by a combination of cochromatography (high-pressure liquid chromatography) with standards and gas chromatography-mass spectrometry. PMID:1768102
Meddings, Jennifer; Reichert, Heidi; Rogers, Mary A M; Hofer, Timothy P; McMahon, Laurence F; Grazier, Kyle L
2015-07-01
To assess the financial effect of the 2008 Hospital-Acquired Conditions Initiative (HACI) pressure ulcer payment changes on Medicare, other payers, and hospitals. Retrospective before-and-after study of all-payer statewide administrative data for more than 2.4 million annual adult discharges in 2007 and 2009 using the Healthcare Cost and Utilization Project State Inpatient Datasets for California. How often and by how much the 2008 payment changes for pressure ulcers affected hospital payment was assessed. Nonfederal acute care California hospitals (N = 311). Adults discharged from acute-care hospitals. Pressure ulcer rates and hospital payment changes. Hospital-acquired pressure ulcer rates were low in 2007 (0.28%) and 2009 (0.27%); present-on-admission pressure ulcer rates increased from 2.3% in 2007 to 3.0% in 2009. According to clinical stage of pressure ulcer (available in 2009), hospital-acquired Stage III and IV ulcers occurred in 603 discharges (0.02%); 60,244 discharges (2.42%) contained other pressure ulcer diagnoses. Payment removal for Stage III and IV hospital-acquired ulcers reduced payment in 75 (0.003%) discharges, for a statewide payment decrease of $310,444 (0.001%) for all payers and $199,238 (0.001%) for Medicare. For all other pressure ulcers, the Hospital-Acquired Conditions Initiative reduced hospital payment in 20,246 (0.81%) cases (including 18,953 cases with present-on-admission ulcers), reducing statewide payment by $62,538,586 (0.21%) for all payers and $47,237,984 (0.32%) for Medicare. The total financial effect of the 2008 payment changes for pressure ulcers was negligible. Most payment decreases occurred by removal of comorbidity payments for present-on-admission pressure ulcers other than Stages III and IV. The removal of payment for hospital-acquired Stage III and IV ulcers by implementation of the HACI policy was 1/200th that of the removal of payment for other types of pressure ulcers that occurred in implementation of the Hospital-Acquired Conditions Initiative. © 2015, Copyright the Authors Journal compilation © 2015, The American Geriatrics Society.
NASA Astrophysics Data System (ADS)
Du, Rongbin; Liu, Liming; Wang, Aimin; Wang, Yongqiang
2013-03-01
Gracilaria asiatica, being highly efficient in nutrient absorption, is cultivated in sea cucumber ponds to remove nutrients such as nitrogen and phosphate. It was cultured in a laboratory simulating field conditions, and its nutrient absorption was measured to evaluate effects of environmental conditions. Ammonia nitrogen (AN), nitrate nitrogen (NN), total inorganic nitrogen (TIN), and soluble reactive phosphorus (SRP) uptake rate and removal efficiency were determined in a 4×2 factorial design experiment in water temperatures ( T) at 15°C and 25°C, algae biomass (AB) at 0.5 g/L and 1.0 g/L, total inorganic nitrogen (TIN) at 30 μmol/L and 60 μmol/L, and soluble reactive phosphorus (SRP) at 3 and 6 μmol/L. AB and ambient TIN or SRP levels significantly affected uptake rate and removal efficiency of AN, NN, TIN, and SRP ( P< 0.001). G. asiatica in AB of 0.5 g/L showed higher uptake rate and lower removal efficiency relative to that with AB of 1.0 g/L. Nitrogen and phosphorus uptake rate rose with increasing ambient nutrient concentrations; nutrient removal efficiency decreased at higher environmental nutrient concentrations. The algae preferred to absorb AN to NN. Uptake rates of AN, NN, and SRP were significantly affected by temperature ( P < 0.001); uptake rate was higher for the 25°C group than for the 15°C group at the initial experiment stage. Only the removal efficiency of AN and SRP showed a significant difference between the two temperature groups ( P< 0.01). The four factors had significant interactive effects on absorption of N and P, implying that G. asiatica has great bioremedial potential in sea cucumber culture ponds.
Simultaneous removal of SO2 and NOx from flue gas by wet scrubbing using a urea solution.
Li, Ge; Wang, Baodong; Xu, Wayne Qiang; Li, Yonglong; Han, Yifan; Sun, Qi
2018-03-27
Nitrogen oxides (NO x ) and sulfur dioxide (SO 2 ) are major air pollutants, so simultaneously removing them from gases emitted during fossil fuel combustion in stationary systems is important. Wet denitrification using urea is used for a wide range of systems. Additives have strong effects on wet denitrification using urea, and different mechanisms are involved and different effects found using different additives. In this study, the effects of different additives, initial urea concentrations, reaction temperatures, initial pH values, gas flow rates, and reaction times on the simultaneous desulfurization and denitrification efficiencies achieved using wet denitrification using urea were studied in single factor experiment. The optimum reaction conditions for desulfurization and denitrification were found. Desulfurization and denitrification efficiencies of 97.5% and 96.3%, respectively, were achieved at a KMnO 4 concentration 5 mmol/L, a reaction temperature of 70°C, initial urea solution pH 8, a urea concentration of 9%, and a gas flow rate of 40 L/h. The concentrations of the desulfurization and denitrification reaction products in the solution were determined. NO x was mainly transformed into N 2 , and the [Formula: see text] and [Formula: see text] concentrations in the solution became very low. The reactions involved in SO 2 and NO x removal using urea were analyzed from the thermodynamic viewpoint. Increasing the temperature was not conducive to the reactions but increased the rate constant, so an optimum temperature was determined. The simultaneous desulfurization and denitrification kinetics were calculated. The urea consumption and [Formula: see text], [Formula: see text], and [Formula: see text] generation reactions were all zero order. The [Formula: see text] generation rate was greater than the [Formula: see text] generation rate. The simultaneous desulfurization and denitrification process and mechanism were studied. The results provide reference data for performing flue gas desulfurization and denitrification in factories.
Removal of phosphate from greenhouse wastewater using hydrated lime.
Dunets, C Siobhan; Zheng, Youbin
2014-01-01
Phosphate (P) contamination in nutrient-laden wastewater is currently a major topic of discussion in the North American greenhouse industry. Precipitation of P as calcium phosphate minerals using hydrated lime could provide a simple, inexpensive method for retrieval. A combination of batch experiments and chemical equilibrium modelling was used to confirm the viability of this P removal method and determine lime addition rates and pH requirements for greenhouse wastewater of varying nutrient compositions. Lime: P ratio (molar ratio of CaMg(OH)₄: PO₄‒P) provided a consistent parameter for estimating lime addition requirements regardless of initial P concentration, with a ratio of 1.5 providing around 99% removal of dissolved P. Optimal P removal occurred when lime addition increased the pH from 8.6 to 9.0, suggesting that pH monitoring during the P removal process could provide a simple method for ensuring consistent adherence to P removal standards. A Visual MINTEQ model, validated using experimental data, provided a means of predicting lime addition and pH requirements as influenced by changes in other parameters of the lime-wastewater system (e.g. calcium concentration, temperature, and initial wastewater pH). Hydrated lime addition did not contribute to the removal of macronutrient elements such as nitrate and ammonium, but did decrease the concentration of some micronutrients. This study provides basic guidance for greenhouse operators to use hydrated lime for phosphate removal from greenhouse wastewater.
Meddings, Jennifer A.; Reichert, Heidi; Rogers, Mary A. M.; Hofer, Timothy P.; McMahon, Laurence F.; Grazier, Kyle L.
2017-01-01
OBJECTIVE To assess the financial impact of the 2008 Hospital-Acquired Conditions Initiative’s pressure ulcer payment changes on Medicare and other payors. DESIGN, SETTING AND PARTICIPANTS Retrospective before-and-after study of all-payor statewide administrative data for >2.4 million annual adult discharges from 311 nonfederal acute-care California hospitals in 2007 and 2009, using the Healthcare Cost and Utilization Project State Inpatient Datasets. We assessed how often and by how much the 2008 payment changes for pressure ulcers affected hospital payment. MEASUREMENTS Pressure ulcer rates and hospital payment changes RESULTS Hospital-acquired pressure ulcer rates were very low (0.28%) in 2007 and 2009; present-on-admission pressure ulcer rates increased from 2.35% in 2007 to 3.00% in 2009. By clinical stage of pressure ulcer (available in 2009), hospital-acquired stage III–IV ulcers occurred in 603 discharges (0.02%); 60,244 discharges (2.42%) contained other pressure ulcer diagnoses. Payment removal for stage III–IV hospital-acquired ulcers reduced payment in 75 (0.003%) discharges for a statewide payment decrease of $310,444 (0.001%) for all payors and $199,238 (0.001%) for Medicare. For all other pressure ulcers, the Hospital-Acquired Conditions Initiative reduced hospital payment in 20,246 (0.81%) cases (including 18,953 cases with present-on-admission ulcers) reducing statewide payment by $62,538,586 (0.21%) for all payors and $47,237,984 (0.32%) for Medicare. CONCLUSION The total financial impact of the 2008 payment changes for pressure ulcers was negligible. Most payment decreases occurred by removal of comorbidity payments for present-on-admission pressure ulcers other than stages III–IV. The removal of payment for hospital-acquired stage III–IV ulcers was more than 200 times less than the removal of payment for other types of pressure ulcers that occurred in implementation of the Hospital-Acquired Conditions Initiative. PMID:26140454
Effects of Dehydration on Fish Muscles at Chilled Temperature
NASA Astrophysics Data System (ADS)
Miki, Hidemasa; Seto, Fuminori; Nishimoto, Motomi; Nishimoto, Junichi
Recently,new method of removing water from fish fillet at low temperature using dehydration sheet have been reported. The present study is concerned with the factors to affect the quality during dehydration of horse mackerel muscle at low temperature. The rate of dehydration at -3 °C was about two times faster than that at 0 °C. The rate of denaturation of fish muscle protein was kept less than about 10 % (ATPase activity) of the undenaturated initial values after removing free water content. Present results suggest the practical possibility of the dehydration at -3 °C for keeping quality of fish flesh.
Ozone reaction with clothing and its initiated VOC emissions in an environmental chamber.
Rai, A C; Guo, B; Lin, C-H; Zhang, J; Pei, J; Chen, Q
2014-02-01
Human health is adversely affected by ozone and the volatile organic compounds (VOCs) produced from its reactions in the indoor environment. Hence, it is important to characterize the ozone-initiated reactive chemistry under indoor conditions and study the influence of different factors on these reactions. This investigation studied the ozone reactions with clothing through a series of experiments conducted in an environmental chamber under various conditions. The study found that the ozone reactions with a soiled (human-worn) T-shirt consumed ozone and generated VOCs. The ozone removal rate and deposition velocity for the T-shirt increased with the increasing soiling level and air change rate, decreased at high ozone concentrations, and were relatively unaffected by the humidity. The deposition velocity for the soiled T-shirt ranged from 0.15 to 0.29 cm/s. The ozone-initiated VOC emissions included C6-C10 straight-chain saturated aldehydes, acetone, and 4-OPA (4-oxopentanal). The VOC emissions were generally higher at higher ozone, humidity, soiling of T-shirt, and air change rate. The total molar yield was approximately 0.5 in most cases, which means that for every two moles of ozone removed by the T-shirt surface, one mole of VOCs was produced. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Intravenous nitroglycerin for controlled cord traction in the management of retained placenta.
Visalyaputra, Shusee; Prechapanich, Japarath; Suwanvichai, Sukanya; Yimyam, Suwimol; Permpolprasert, Ladda; Suksopee, Pattipa
2011-02-01
To determine the effect of 200 μg of intravenous nitroglycerin in the release of retained placenta by controlled cord traction. In this randomized controlled study, 40 women with a placenta retained for 30 minutes received intravenously 200 μg of nitroglycerin or a normal saline solution before umbilical cord traction was initiated. The rates of successful removal of the retained placenta in the study (n=20) and control (n=20) groups were compared, as were blood pressure, pulse rate, blood loss, and adverse effects. The placenta was released in only 15% and 20% of the participants in the study and control group, respectively. The remainder of the participants required general anesthesia and manual removal of the retained placenta regardless of group assignation. Blood pressure fell in significantly more women in the study group, but there were no differences in estimated blood loss or minor adverse effects. Intravenously administered nitroglycerin did not facilitate the release of retained placenta by umbilical cord traction. However, cord traction may be performed longer than 30 minutes to attempt releasing the placenta before operative manual removal is initiated. Copyright © 2010 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Weilnboeck, F.; Fox-Lyon, N.; Oehrlein, G. S.; Doerner, R. P.
2010-02-01
A profound influence of monolayer tungsten coverage of hard carbon films on the evolution of carbon surface erosion behaviour, surface chemistry and morphology in D2 plasma has been established by real-time ellipsometry, x-ray photoelectron spectroscopy and atomic force microscopy measurements. The erosion of tungsten-covered carbon showed two distinct stages of plasma material interactions: rapid tungsten removal during the initial erosion period and steady-state amorphous carbon removal accompanied by large-scale surface roughness development. The initial removal of tungsten takes place at a rate that significantly exceeds typical sputter yields at the ion energies used here and is attributed to elimination of weakly bonded tungsten from the surface. The tungsten remaining on the a-C : H film surface causes surface roughness development of the eroding carbon surface by a masking effect, and simultaneously leads to a seven fold reduction of the steady-state carbon erosion rate for long plasma surface interaction times (~100 s). Results presented are of direct relevance for material transport and re-deposition, and the interaction of those films with plasma in the divertor region and on mirror surfaces of fusion devices.
NASA Technical Reports Server (NTRS)
Knox, James C.; Stanley, Christine M.
2015-01-01
The Life Support Systems Project (LSSP) under the Advanced Exploration Systems (AES) program builds upon the work performed under the AES Atmosphere Resource Recovery and Environmental Monitoring (ARREM) project focusing on the numerous technology development areas. The Carbon Dioxide (CO2) removal and associated air drying development efforts are focused on improving the current state-of-the-art system on the International Space Station (ISS) utilizing fixed beds of sorbent pellets by seeking more robust pelletized sorbents, evaluating structured sorbents, and examining alternate bed configurations to improve system efficiency and reliability. A component of the CO2 removal effort utilizes a virtual Carbon Dioxide Removal Assembly, revision 4 (CDRA-4) test bed to test a large number of potential operational configurations with independent variations in flow rate, cycle time, heater ramp rate, and set point. Initial ground testing will provide prerequisite source data and provide baseline data in support of the virtual CDRA. Once the configurations with the highest performance and lowest power requirements are determined by the virtual CDRA, the results will be confirmed by testing these configurations with the CDRA-4EU ground test hardware. This paper describes the initial ground testing of select configurations. The development of the virtual CDRA under the AES-LSS Project will be discussed in a companion paper.
Wang, Qinghai; Li, Cui; Zheng, Ruilun; Que, Xiaoe
2016-08-01
The potential of Acorus calamus to remove chlorpyrifos from water was assessed under laboratory conditions. Toxic effects of the insecticide in A. calamus were evaluated using pulse-amplitude modulated chlorophyll fluorescence techniques as well. At exposure concentrations above 8 mg L(-1), A. calamus showed obvious phytotoxic symptom with significant reduction in quantum efficiency of PSII (ΦPSII) and photochemical quenching coefficient (qP) in 20-day test; the inhibition of maximal quantum efficiency of PSII (Fv/Fm) was accompanied by a significant rise in initial chlorophyll fluorescence (Fo) within 15-day exposures. Fv/Fm and Fo recover to the normal level after 20-day exposure. The reduced removal rate to chlorpyrifos was observed with increase of initial chlorpyrifos concentrations. At application levels of 1, 2, and 4 mg L(-1), the disappearance rate of chlorpyrifos in the hydroponic system with plants was significantly greater than that without plants during the 20-day test periods. Chlorpyrifos was taken up from medium and transferred to above ground tissues by the plant and significant amounts of chlorpyrifos accumulated in plant tissues. The result indicated that A. calamus can promote the disappearance of chlorpyrifos from water and may be used for phytoremediation of water contaminated with a relatively low concentration of chlorpyrifos insecticide (<4 mg L(-1)).
Biodegradation of a surrogate naphthenic acid under denitrifying conditions.
Gunawan, Yetty; Nemati, Mehdi; Dalai, Ajay
2014-03-15
Extraction of bitumen from the shallow oil sands generates extremely large volumes of waters contaminated by naphthenic acid which pose severe environmental and ecological risks. Aerobic biodegradation of NA in properly designed bioreactors has been investigated in our earlier works. In the present work, anoxic biodegradation of trans-4-methyl-1-cyclohexane carboxylic acid (trans-4MCHCA) coupled to denitrification was investigated as a potential ex situ approach for the treatment of oil sand process waters in bioreactors whereby excessive aeration cost could be eliminated, or as an in situ alternative for the treatment of these waters in anoxic stabilization ponds amended with nitrate. Using batch and continuous reactors (CSTR and biofilm), effects of NA concentration (100-750mgL(-1)), NA loading rate (up to 2607.9mgL(-1)h(-1)) and temperature (10-35°C) on biodegradation and denitrification processes were evaluated. In the batch system biodegradation of trans-4MCHCA coupled to denitrification occurred even at the highest concentration of 750mgL(-1). Consistent with the patterns reported for aerobic biodegradation, increase in initial concentration of NA led to higher biodegradation and denitrification rates and the optimum temperature was determined as 23-24°C. In the CSTR, NA removal and nitrate reduction rates passed through a maximum due to increases in NA loading rate. NA loading rate of 157.8mgL(-1)h(-1) at which maximum anoxic NA and nitrate removal rates (105.3mgL(-1)h(-1) and 144.5mgL(-1)h(-1), respectively) occurred was much higher than those reported for the aerobic alternative (NA loading and removal rates: 14.2 and 9.6mgL(-1)h(-1), respectively). In the anoxic biofilm reactor removal rates of NA and nitrate were dependent on NA loading rate in a linear fashion for the entire range of applied loading rates. The highest loading and removal rates for NA were 2607.9 and 2028.1mgL(-1)h(-1), respectively which were at least twofold higher than the values reported for the aerobic biofilm reactor. The highest nitrate removal rate coincided with maximum removal rate of NA and was 3164.7mgL(-1)h(-1). Copyright © 2014 Elsevier Ltd. All rights reserved.
Wu, Bin; Peng, Dinghua; Hou, Siyu; Tang, Bicong; Wang, Can; Xu, Heng
2018-05-16
In this study, the dynamic Cr(VI) removal process from water by the synthesized multilayer material coated nanoscale zerovalent iron (SBC-nZVI) was systematically discussed at different treatment conditions. The results showed that initial pH, contact time, Cr(VI) concentration and the dosage of SBC-nZVI were important parameters that influenced the Cr(VI) removal efficiency. The major Cr(VI) removal occurred within 60 min and gradually tend to equilibrium with consistent treatment. The removal efficiency was highly depended on pH values and the adsorption kinetics agreed well with the pseduo-second-order model (PSO). When the initial Cr(VI) concentration was below 15 mg/L, the removal rate could reach to about 100%. Moreover, the removal efficiency increased with the increase of SBC-nZVI dosage, which related to the increase of reactive sites. To understand the removal mechanism, SBC-nZVI before and after reaction with Cr(VI) were characterized by fourier transform infrared spectra (FTIR), X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive spectrometer (EDS), and X-ray photoelectron spectroscopy (XPS). These analysis showed that the interaction of SBC-nZVI with Cr(VI) was mainly controlled by reduction and electrostatic attraction. Therefore, these results explained the interaction between Cr(VI) and SBC-nZVI material in detail, and further proved that SBC-nZVI could be an effective material to remove Cr(VI) from water. Copyright © 2018. Published by Elsevier Ltd.
Harrington, T.B.; Tappeiner, John C.
1997-01-01
At two sites in southwestern Oregon, height, diameter, and crown width of young Douglas-fir (Pseudotsuga menziesii) and sprout-origin tanoak (Lithocarpus densiflorus) were measured 1–11 years after reducing the density of a 2-year-old tanoak stand to 0%, 25%, 50%, and 100% of its initial cover. Some plots also included suppression of understory vegetation. Tanoak cover developed linearly with time, with steepness of the growth trajectory increasing at a diminishing rate with increasing percentage of initial tanoak cover. Fifth-year cover of understory vegetation declined linearly with increasing percentage of initial tanoak cover (R2 = 0.29). Survival of Douglas-fir (96–100%) differed little among initial abundances of tanoak, while growth trajectories for its size became increasingly exponential with decreasing percentage of initial tanoak cover. Eleventh-year heights of Douglas-fir were similar for 0%, 25%, and 50% of initial tanoak cover; however, diameter increased linearly with decreasing percentage of initial tanoak cover (R2 = 0.73), and the slope of the relationship steepened with understory suppression. Our results indicate that young stands exhibiting a wide range of stand compositions and productivities can be established by early manipulations of tanoak and understory abundance. Complete removal of tanoak plus understory suppression are necessary to maximize Douglas-fir growth, while productive, mixed stands can be achieved by removing 50% or more of tanoak cover.
Tong, Yiran; He, Zhen
2013-11-15
This research aims to develop a new approach for in situ nitrate removal from groundwater by using a bioelectrochemical system (BES). The BES employs bioelectricity generated from organic compounds to drive nitrate moving from groundwater into the anode and reduces nitrate to nitrogen gas by heterotrophic denitrification. This laboratory study of a bench-scale BES demonstrated effective nitrate removal from both synthetic and actual groundwater. It was found that applying an electrical potential improved the nitrate removal and the highest nitrate removal rate of 208.2 ± 13.3g NO3(-)-Nm(-3) d(-1) was achieved at 0.8 V. Although the open circuit condition (no electricity generation) still resulted in a nitrate removal rate of 158.5 ± 4.2 gm(-3) d(-1) due to ion exchange, electricity production could inhibit ion exchange and prevent introducing other undesired ions into groundwater. The nitrate removal rate exhibited a linear relationship with the initial nitrate concentration in groundwater. The BES produced a higher current density of 33.4 Am(-3) and a higher total coulomb of 244.7 ± 9.1C from the actual groundwater than the synthetic groundwater, likely because other ions in the actual groundwater promoted ion movement to assist electricity generation. Further development of this BES will need to address several key challenges in anode feeding solution, ion competition, and long-term stability. Copyright © 2013 Elsevier B.V. All rights reserved.
Removal of dichloromethane from waste gas streams using a hybrid bubble column/biofilter bioreactor
2014-01-01
The performance of a hybrid bubble column/biofilter (HBCB) bioreactor for the removal of dichloromethane (DCM) from waste gas streams was studied in continuous mode for several months. The HBCB bioreactor consisted of two compartments: bubble column bioreactor removing DCM from liquid phase and biofilter removing DCM from gas phase. Effect of inlet DCM concentration on the elimination capacity was examined in the DCM concentration range of 34–359 ppm with loading rates ranged from 2.2 to 22.8 g/m3.h and constant total empty bed retention time (EBRT) of 200 s. In the equal loading rates, the elimination capacity and removal efficiency of the biofilter were higher than the corresponding values of the bubble column bioreactor. The maximum elimination capacity of the HBCB bioreactor was determined to be 15.7 g/m3.h occurred in the highest loading rate of 22.8 g/m3.h with removal efficiency of 69%. The overall mineralization portion of the HBCB bioreactor was in the range of 72-79%. The mixed liquor acidic pH especially below 5.5 inhibited microbial activity and decreased the elimination capacity. Inhibitory effect of high ionic strength was initiated in the mixed liquor electrical conductivity of 12.2 mS/cm. This study indicated that the HBCB bioreactor could benefit from advantages of both bubble column and biofilter reactors and could remove DCM from waste gas streams in a better manner. PMID:24406056
Zhu, Xinbo; Tu, Xin; Mei, Danhua; Zheng, Chenghang; Zhou, Jinsong; Gao, Xiang; Luo, Zhongyang; Ni, Mingjiang; Cen, Kefa
2016-07-01
In this work, plasma-catalytic removal of low concentrations of acetone over CuO/γ-Al2O3 catalysts was carried out in a cylindrical dielectric barrier discharge (DBD) reactor. The combination of plasma and the CuO/γ-Al2O3 catalysts significantly enhanced the removal efficiency of acetone compared to the plasma process using the pure γ-Al2O3 support, with the 5.0 wt% CuO/γ-Al2O3 catalyst exhibiting the best acetone removal efficiency of 67.9%. Catalyst characterization was carried out to understand the effect the catalyst properties had on the activity of the CuO/γ-Al2O3 catalysts in the plasma-catalytic reaction. The results indicated that the formation of surface oxygen species on the surface of the catalysts was crucial for the oxidation of acetone in the plasma-catalytic reaction. The effects that various operating parameters (discharge power, flow rate and initial concentration of acetone) and the interactions between these parameters had on the performance of the plasma-catalytic removal of acetone over the 5.0 wt% CuO/γ-Al2O3 catalyst were investigated using central composite design (CCD). The significance of the independent variables and their interactions were evaluated by means of the Analysis of Variance (ANOVA). The results showed that the gas flow rate was the most significant factor affecting the removal efficiency of acetone, whilst the initial concentration of acetone played the most important role in determining the energy efficiency of the plasma-catalytic process. Copyright © 2016 Elsevier Ltd. All rights reserved.
Rapid fabrication of a silicon modification layer on silicon carbide substrate.
Bai, Yang; Li, Longxiang; Xue, Donglin; Zhang, Xuejun
2016-08-01
We develop a kind of magnetorheological (MR) polishing fluid for the fabrication of a silicon modification layer on a silicon carbide substrate based on chemical theory and actual polishing requirements. The effect of abrasive concentration in MR polishing fluid on material removal rate and removal function shape is investigated. We conclude that material removal rate will increase and tends to peak value as the abrasive concentration increases to 0.3 vol. %, and the removal function profile will become steep, which is a disadvantage to surface frequency error removal at the same time. The removal function stability is also studied and the results show that the prepared MR polishing fluid can satisfy actual fabrication requirements. An aspheric reflective mirror of silicon carbide modified by silicon is well polished by combining magnetorheological finishing (MRF) using two types of MR polishing fluid and computer controlled optical surfacing (CCOS) processes. The surface accuracy root mean square (RMS) is improved from 0.087λ(λ=632.8 nm) initially to 0.020λ(λ=632.8 nm) in 5.5 h total and the tool marks resulting from MRF are negligible. The PSD analysis results also shows that the final surface is uniformly polished.
Vivek Narayanan, N; Ganesan, Mahesh
2009-01-15
The present work deals with removal of hexavalent chromium from synthetic effluents in a batch stirred electrocoagulation cell with iron-aluminium electrode pair coupled with adsorption using granular activated carbon (GAC). Several working parameters such as pH, current density, adsorbent concentration and operating time were studied in an attempt to achieve higher removal capacity. Results obtained with synthetic wastewater revealed that most effective removal capacities of chromium (VI) could be achieved when the initial pH was near 8. The removal of chromium (VI) during electrocoagulation, is due to the combined effect of chemical precipitation, coprecipitation, sweep coagulation and adsorption. In addition, increasing current density in a range of 6.7-26.7mA/cm2 and operating time from 20 to 100min enhanced the treatment rate to reduce metal ion concentration below admissible legal levels. The addition of GAC as adsorbent resulted in remarkable increase in the removal rate of chromium at lower current densities and operating time, than the conventional electrocoagulation process. The method was found to be highly efficient and relatively fast compared to existing conventional techniques.
Effect of CO₂ flow rate on the Pinang frond-based activated carbon for methylene blue removal.
Herawan, S G; Ahmad, M A; Putra, A; Yusof, A A
2013-01-01
Activated carbons are regularly used the treatment of dye wastewater. They can be produced from various organics materials having high level of carbon content. In this study, a novel Pinang frond activated carbon (PFAC) was produced at various CO₂ flow rates in the range of 150-600 mL/min at activation temperature of 800°C for 3 hours. The optimum PFAC sample is found on CO₂ flow rate of 300 mL/min which gives the highest BET surface area and pore volume of 958 m²/g and 0.5469 mL/g, respectively. This sample shows well-developed pore structure with high fixed carbon content of 79.74%. The removal of methylene blue (MB) by 95.8% for initial MB concentration of 50 mg/L and 72.6% for 500 mg/L is achieved via this sample. The PFAC is thus identified to be a suitable adsorbent for removing MB from aqueous solution.
Huang, Xiao; Bai, Jie; Li, Kui-Ran; Zhao, Yang-Guo; Tian, Wei-Jun; Dang, Jia-Jia
2017-01-15
To achieve a better contaminant removal efficiency in a low-temperature and high-salt environment, two novel strains of cold- and salt-tolerant ammonia-oxidizing bacteria (AOB), i.e., Ochrobactrum sp. (HXN-1) and Aquamicrobium sp. (HXN-2), were isolated from the surface sediment of Liaohe Estuarine Wetland (LEW), China. The optimization of initial ammonia nitrogen concentration, pH, carbon-nitrogen ratio, and petroleum hydrocarbons (PHCs) to improve the ammonia-oxidation capacity of the two bacterial strains was studied. Both bacterial strains showed a high ammonia nitrogen removal rate of over 80% under a high salinity of 10‰. Even at a temperature as low as 15°C, HXN-1 and HXN-2 could achieve an ammonia nitrogen removal rate of 53% and 62%, respectively. The cold- and salt-tolerant AOB in this study demonstrated a high potential for ammonia nitrogen removal from LEW. Copyright © 2016 Elsevier Ltd. All rights reserved.
Manna, Suvendu; Saha, Prosenjit; Roy, Debasis; Adhikari, Basudam; Das, Papita
2018-04-15
Fluoride has both detrimental and beneficial effects on living beings depending on the concentration and consumption periods. The study presented in this article investigated the feasibility of using neem oil phenolic resin treated lignocellulosic bio-sorbents for fluoride removal from water through fixed bed column study. Results indicated that treated bio-sorbents could remove fluoride both from synthetic and groundwater with variable bed depth, flow rate, fluoride concentration and column diameter. Data obtained from this study indicated that columns with the thickest bed, lowest flow rate, and fluoride concentration showed best column performance. Bio-sorbents used in this study are regenerable and reusable for more than five cycles. The initial materials cost needed to remove one gram of fluoride also found to be lower than the available alternatives. This makes the process more promising candidate to be used for fluoride removal. In addition, the process is also technically advantageous over the available alternatives. Copyright © 2018 Elsevier Ltd. All rights reserved.
Zhou, Jun; Sun, Qianyu; Chen, Dan; Wang, Hongyu; Yang, Kai
2017-10-01
In this study, the hydrogenotrophic denitrifying bacterium Ochrobactrum anthropi was added in to the process of nitrate removal by starch-stabilized nanoscale zero valent iron (nZVI) to minimize undesirable ammonium. The ammonium control performance and cooperative mechanism of this combined process were investigated, and batch experiments were conducted to discuss the effects of starch-stabilized nZVI dose, biomass, and pH on nitrate reduction and ammonium control of this system. The combined system achieved satisfactory performance because the anaerobic iron corrosion process generates H 2 , which is used as an electron donor for the autohydrogenotrophic bacterium Ochrobactrum anthropi to achieve the autohydrogenotrophic denitrification process converting nitrate to N 2 . When starch-stabilized nZVI dose was increased from 0.5 to 2.0 g/L, nitrate reduction rate gradually increased, and ammonium yield also increased from 9.40 to 60.51 mg/L. Nitrate removal rate gradually decreased and ammonium yield decreased from 14.93 to 2.61 mg/L with initial OD 600 increasing from 0.015 to 0.080. The abiotic Fe 0 reduction process played a key role in nitrate removal in an acidic environment and generated large amounts of ammonium. Meanwhile, the nitrate removal rate decreased and ammonium yield also reduced in an alkaline environment.
Tsolcha, Olga N; Tekerlekopoulou, Athanasia G; Akratos, Christos S; Antonopoulou, Georgia; Aggelis, George; Genitsaris, Savvas; Moustaka-Gouni, Maria; Vayenas, Dimitrios V
2018-04-22
A mixed cyanobacterial-mixotrophic algal population, dominated by the filamentous cyanobacterium Leptolyngbya sp. and the microalga Ochromonas (which contributed to the total photosynthetic population with rates of less than 5%), was studied under non-aseptic conditions for its efficiency to remove organic and inorganic compounds from different types of wastes/wastewaters while simultaneously producing lipids. Second cheese whey, poplar sawdust, and grass hydrolysates were used in lab-scale experiments, in photobioreactors that operated under aerobic conditions with different initial nutrient (C, N and P) concentrations. Nutrient removal rates, biomass productivity, and the maximum oil production rates were determined. The highest lipid production was achieved using the biologically treated dairy effluent (up to 14.8% oil in dry biomass corresponding to 124 mg L -1 ) which also led to high nutrient removal rates (up to 94%). Lipids synthesized by the microbial consortium contained high percentages of saturated and mono-unsaturated fatty acids (up to 75% in total lipids) for all the substrates tested, which implies that the produced biomass may be harnessed as a source of biodiesel.
Zielinski, Robert A.
1979-01-01
Well-characterized samples of rhyolitic obsidian, perlite and felsite from a single lava flow are leached of U by alkaline oxidizing solutions under open-system conditions. Pressure, temperature, flow rate and solution composition are held constant in order to evaluate the relative importance of differences in surface area and crystallinity. Under the experimental conditions U removal from crushed glassy samples proceeds by a mechanism of glass dissolution in which U and silica are dissolved in approximately equal weight fractions. The rate of U removal from crushed glassy samples increases with decreasing average grain size (surface area). Initial rapid loss of a small component (≈ 2.5%) of the total U from crushed felsite. followed by much slower U loss, reflects variable rates of attack of numerous uranium sites. The fractions of U removed during the experiment ranged from 3.2% (felsite) to 27% (perlite). An empirical method for evaluating the relative rate of U loss from contemporaneous volcanic rocks is presented which incorporates leaching results and rock permeability data.
Removal of copper powder from aqueous solution by cementation using an agitated vessel.
Amin, N K; El-Ashtouky, E-S Z; Abdelwahab, O
2014-01-01
The present study is concerned with the removal of copper powder from aqueous solution by cementation on a stationary disc placed inside an agitated vessel. The influence of several parameters on the rate of cementation, such as initial copper sulphate concentration, impeller rotational speed, presence of surfactant (Triton X-100), distance between the disc and the impeller, type of blade turbine and presence of baffles, has been investigated. The rate of cementation was found to increase with increasing impeller rotational speed and initial copper sulphate concentration. On the other hand, the rate decreases with increasing distance between the disc and the impeller. The rate of cementation was inhibited in solutions containing Triton X-100. Performance of a four-blade 90 degree turbine with regard to the rate of copper cementation was superior to the performance of a four-blade 45 degree pitched turbine. The present data can be correlated in terms of mass transfer coefficient of cementation as Sh = 0.905 Sc0.33 Re0.89 (d/l)0.41 (four-blade 90 degree turbine); Sh = 0.815 Sc0.33Re0.79 (d/l)0.47 (four-blade 45 degree pitched turbine), for the conditions 2035 < Sc < 2810 and 35,000 < Re < 179,000.
Removal of inorganic mercury from aquatic environments by multi-walled carbon nanotubes.
Yaghmaeian, Kamyar; Khosravi Mashizi, Reza; Nasseri, Simin; Mahvi, Amir Hossein; Alimohammadi, Mahmood; Nazmara, Shahrokh
2015-01-01
Mercury is considered as a toxic heavy metal in aquatic environments due to accumulation in bodies of living organisms. Exposure to mercury may lead to different toxic effects in humans including damages to kidneys and nervous system. Multi-walled carbon nanotubes (MWCNTs) were selected as sorbent to remove mercury from aqueous solution using batch technique. ICP instrument was used to determine the amount of mercury in solution. Moreover, pH, contact time and initial concentration of mercury were studied to determine the influence of these parameters on the adsorption conditions. Results indicate that the adsorption strongly depended on pH and the best pH for adsorption is about 7. The rate of adsorption process initially was rapid but it was gradually reduced with increasing of contact time and reached the equilibrium after 120 min. In addition, more than 85 % of initial concentration of 0.1 mg/l was removed at 0.5 g/l concentration of sorbent and contact time of 120 min. Meanwhile, the adsorption process followed the pseudo second-order model and the adsorption isotherms could be described by both the Freundlich and the Langmuir models. This study showed that MWCNTs can effectively remove inorganic mercury from aqueous solutions as adsorbent.
Luna, Airton J; Nascimento, Cláudio A O; Foletto, Edson Luiz; Moraes, José E F; Chiavone-Filhoe, Osvaldo
2014-01-01
In this work, a saline aqueous solution of phenol, 2,4-dichlorophenoxyacetic acid (2,4-D) and 2,4-dichlorophenol (2,4-DCP) was treated by the photo-Fenton process in a falling-film solar reactor. The influence of the parameters such as initial pH (5-7), initial concentration of Fe2+ (1-2.5mM) and rate of H202 addition (1.87-3.74mmol min-1) was investigated. The efficiency of photodegradation was determined from the removal of dissolved organic carbon (DOC), described by the species degradation of phenol, 2,4-D and 2,4-DCP. Response surface methodology was employed to assess the effects of the variables investigated, i.e. [Fe2+], [H202] and pH, in the photo-Fenton process with solar irradiation. The results reveal that the variables' initial concentration of Fe2+ and H202 presents predominant effect on pollutants' degradation in terms of DOC removal, while pH showed no influence. Under the most adequate experimental conditions, about 85% DOC removal was obtained in 180 min by using a reaction system employed here, and total removal of phenol, 2,4- and 2,4-DCP mixture in about 30min.
Huang, Yuanxing; Cui, Chenchen; Zhang, Daofang; Li, Liang; Pan, Ding
2015-01-01
Iron-loaded activated carbon was prepared and used as catalyst in heterogeneous catalytic ozonation of dibutyl phthalate (DBP). The catalytic activity of iron-loaded activated carbon was investigated under various conditions and the mechanisms of DBP removal were deduced. Characterization of catalyst indicated that the iron loaded on activated carbon was mainly in the form of goethite, which reduced its surface area, pore volume and pore diameter. The presence of metals on activated carbon positively contributed to its catalytic activity in ozonation of DBP. Iron loading content of 15% and initial water pH of 8 achieved highest DBP removal among all the tried conditions. Catalyst dosage of 10 mg L(-1) led to approximately 25% of increase in DBP (initial concentration 2 mg L(-1)) removal in 60 min as compared with ozone alone, and when catalyst dosage increased to 100 mg L(-1), the DBP removal was further improved by 46%. Based on a comparison of reaction rates for direct and indirect transformation of DBP, the increased removal of DBP in this study likely occurred via transformation of ozone into hydroxyl radicals on the catalyst surface. Copyright © 2014 Elsevier Ltd. All rights reserved.
Nitrate removal with lateral flow sulphur autotrophic denitrification reactor.
Lv, Xiaomei; Shao, Mingfei; Li, Ji; Xie, Chuanbo
2014-01-01
An innovative lateral flow sulphur autotrophic denitrification (LFSAD) reactor was developed in this study; the treatment performance was evaluated and compared with traditional sulphur/limestone autotrophic denitrification (SLAD) reactor. Results showed that nitrite accumulation in the LFSAD reactor was less than 1.0 mg/L during the whole operation. Denitrification rate increased with the increased initial alkalinity and was approaching saturation when initial alkalinity exceeded 2.5 times the theoretical value. Higher influent nitrate concentration could facilitate nitrate removal capacity. In addition, denitrification efficiency could be promoted under an appropriate reflux ratio, and the highest nitrate removal percentage was achieved under reflux ratio of 200%, increased by 23.8% than that without reflux. Running resistance was only about 1/9 of that in SLAD reactor with equal amount of nitrate removed, which was the prominent excellence of the new reactor. In short, this study indicated that the developed reactor was feasible for nitrate removal from waters with lower concentrations, including contaminated surface water, groundwater or secondary effluent of municipal wastewater treatment with fairly low running resistance. The innovation in reactor design in this study may bring forth new ideas of reactor development of sulphur autotrophic denitrification for nitrate-contaminated water treatment.
Nguyen, Dinh Duc; Yoon, Yong Soo; Bui, Xuan Thanh; Kim, Sung Su; Chang, Soon Woong; Guo, Wenshan; Ngo, Huu Hao
2017-11-01
Performance of an electrocoagulation (EC) process in batch and continuous operating modes was thoroughly investigated and evaluated for enhancing wastewater phosphorus removal under various operating conditions, individually or combined with initial phosphorus concentration, wastewater conductivity, current density, and electrolysis times. The results revealed excellent phosphorus removal (72.7-100%) for both processes within 3-6 min of electrolysis, with relatively low energy requirements, i.e., less than 0.5 kWh/m 3 for treated wastewater. However, the removal efficiency of phosphorus in the continuous EC operation mode was better than that in batch mode within the scope of the study. Additionally, the rate and efficiency of phosphorus removal strongly depended on operational parameters, including wastewater conductivity, initial phosphorus concentration, current density, and electrolysis time. Based on experimental data, statistical model verification of the response surface methodology (RSM) (multiple factor optimization) was also established to provide further insights and accurately describe the interactive relationship between the process variables, thus optimizing the EC process performance. The EC process using iron electrodes is promising for improving wastewater phosphorus removal efficiency, and RSM can be a sustainable tool for predicting the performance of the EC process and explaining the influence of the process variables.
Mohanty, Sanjay K; Boehm, Alexandria B
2014-10-07
Bioretention systems and biofilters are used in low impact development to passively treat urban stormwater. However, these engineered natural systems are not efficient at removing fecal indicator bacteria, the contaminants responsible for a majority of surface water impairments. The present study investigates the efficacy of biochar-augmented model sand biofilters for Escherichia coli removal under a variety of stormwater bacterial concentrations and infiltration rates. Additionally, we test the role of biochar particle size and "presence of compost on model" biofilter performance. Our results show that E. coli removal in a biochar-augmented sand biofilter is ∼ 96% and is not greatly affected by increases in stormwater infiltration rates and influent bacterial concentrations, particularly within the ranges expected in field. Removal of fine (<125 μm) biochar particles from the biochar-sand biofilter decreased the removal capacity from 95% to 62%, indicating biochar size is important. Addition of compost to biochar-sand biofilters not only lowered E. coli removal capacity but also increased the mobilization of deposited bacteria during intermittent infiltration. This result is attributed to exhaustion of attachment sites on biochar by the dissolved organic carbon leached from compost. Overall, our study indicates that biochar has potential to remove bacteria from stormwater under a wide range of field conditions, but for biochar to be effective, the size should be small and biochar should be applied without compost. Although the results aid in the optimization of biofilter design, further studies are needed to examine biochar potential in the field over an entire rainy season.
Effects of pH buffering agents on the anaerobic hydrolysis acidification stage of kitchen waste.
Wang, Yaya; Zang, Bing; Gong, Xiaoyan; Liu, Yu; Li, Guoxue
2017-10-01
This study investigated effects of initial pH buffering agents on the lab-scale anaerobic hydrolysis acidification stage of kitchen waste (KW). Different cheap, available and suitable buffering agents (NaOH(s), NaOH(l), CaO(s)-NaOH, KOH(l)-NaOH, K 2 HPO 4 (s)-KOH, Na 2 CO 3 (s)-NaOH) were added under optimal adjusting mode (first two days: per 16h, after: one time per day) which was obtained in previous work. The effects of buffering agents were evaluated according to indexes of pH, VFAs, NH 4 + -N, TS, VS, VS/TS, TS and VS removal rate. The results showed treatment 5 with adding K 2 HPO 4 -KOH buffering agents had the most stable pH (6.7-7.0). Also treatment 5, 2, 4 and 6 provided stable pH ranging in 5-8. Among the treatments, treatment 6 with adding Na 2 CO 3 as initial buffering agents and 10mol/L NaOH as regulator was chosen as the optimal mode for highest VFAs content (44.05g/L) with high acetic acid and butyrate acid proportion (42.64%), TS and VS removal rate (44.84% and 58.67%, respectively), low VS/TS ratio (58.55), fewer adding dosage and low adjusting frequency. The VFAs content of treatment 6 at the end of hydrolysis acidification stage could be used for methanogenic phase of anaerobic two-phase digestion. Thus, treatment 6 (adding Na 2 CO 3 as initial buffering agents and 10mol/L NaOH as regulator) with highest VFAs content and TS and VS removal rate could be considered using in anaerobic hydrolysis acidification stage pH adjustment. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ou, Ling; Gannon, Travis W; Polizzotto, Matthew L
2017-11-01
Monosodium methyl arsenate (MSMA), a common arsenical herbicide, is a major contributor of anthropogenic arsenic (As) to the environment. Uncertainty about controls on MSMA fate and the rates and products of MSMA species transformation limits effective MSMA regulation and management. The main objectives of this research were to quantify the kinetics and mechanistic drivers of MSMA species transformation and removal from solution by soil. Laboratory MSMA incubation studies with two soils and varying soil organic carbon (SOC) levels were conducted. Arsenic removal from solution was more extensive and faster in sandy clay loam incubations than sand incubations, but for both systems, As removal was biphasic, with initially fast removal governed by sorption, followed by slower As removal limited by species transformation. Dimethylarsinic acid was the dominant product of species transformation at first, but inorganic As(V) was the ultimate transformation product by experiment ends. SOC decreased As removal and enhanced As species transformation, and SOC content had linear relationships with As removal rates (R 2 = 0.59-0.95) for each soil and reaction phase. These results reveal the importance of edaphic conditions on inorganic As production and overall mobility of As following MSMA use, and such information should be considered in MSMA management and regulatory decisions. Copyright © 2017 Elsevier Ltd. All rights reserved.
Remote operation of an orbital maneuvering vehicle in simulated docking maneuvers
NASA Technical Reports Server (NTRS)
Brody, Adam R.
1990-01-01
Simulated docking maneuvers were performed to assess the effect of initial velocity on docking failure rate, mission duration, and delta v (fuel consumption). Subjects performed simulated docking maneuvers of an orbital maneuvering vehicle (OMV) to a space station. The effect of the removal of the range and rate displays (simulating a ranging instrumentation failure) was also examined. Naive subjects were capable of achieving a high success rate in performing simulated docking maneuvers without extensive training. Failure rate was a function of individual differences; there was no treatment effect on failure rate. The amount of time subjects reserved for final approach increased with starting velocity. Piloting of docking maneuvers was not significantly affected in any way by the removal of range and rate displays. Radial impulse was significant both by subject and by treatment. NASA's 0.1 percent rule, dictating an approach rate no greater than 0.1 percent of the range, is seen to be overly conservative for nominal docking missions.
[Screening and ammoxidation characteristics of an ammonium oxidizing bacteria group].
Yang, Xiaolong; Liu, Lihua; Wu, Bingqi; Liu, Shujie; Chen, Fuming
2015-12-04
This study aimed to screen high-performance ammonia oxidizing bacteria ( AOB) resistant to a high concentration of ammonia-nitrogen and low C/N ratio, for the development of novel AOB agents. Multi-point sampling, compulsory domestication, gradient dilution of domestication liquid were conducted to screen AOB with efficient and stable ammonia-nitrogen removing ability, and effects of different factors on its ammoxidation ability including C/N ratio, shaking speed and ammonia-nitrogen concentration were studied. Dominant strains were screened and identified by morphological observation, physiological and biochemical properties test and 16S rRNA sequence analysis. Three efficient AOB were obtained, among them a micro-flora named JQ8 showed the highest activity. The ammonia-nitrogen removal rate reached 95. 07% in a simulated wastewater with 17. 86 mmol/L of initial ammonia-nitrogen at C/N 4 treated by JQ8 for 6 days. Moreover, its ammonia nitrogen removal rate kept above 95% and net nitrogen removing rate nearly 80% in the solution with a C/N ratio above 4 and an NH₄⁺-N concentration below 28.57 mmol/L. The circuit board industry wastewater was treated using the laboratory-simulated aerobic active sludge disposal system. The removal rate of NH₄⁺-N and total nitrogen reached 87.8% and 67.6% respectively after 7 days' treatment using JQ8. Defluvibacter sp., Paracoccus sp. and Aquamicrobium sp. were identified as the dominant strains after the composition analysis of JQ8. An ammonia oxidizing bacteria consortium JQ8 screened from the landfill leachate showed a strong ammonium-nitrogen removal and endurance ability under low C/N ratio and high ammonia-nitrogen concentration, thus is probably applicable to intensify the ammonia-nitrogen removal treatment of industrial wastewater with sewage disposal system.
Kida, M; Miyazawa, S; Iwai, T; Ikeda, H; Takezawa, M; Kikuchi, H; Watanabe, M; Imaizumi, H; Koizumi, W
2011-12-01
Recent progress in chemotherapy has prolonged the survival of patients with malignant biliary strictures, leading to increased rates of stent occlusion. Occlusion of covered metallic stents now occurs in about half of all patients with malignant biliary strictures. The removal of metallic stents followed by placement of a second stent has been attempted, but outcomes remain controversial. The aim of the current study was to evaluate the effectiveness and safety of the primary placement and secondary placement (re-intervention) of covered metallic stents and to assess the feasibility and safety of stent removal. The study included 186 patients with unresectable malignant biliary strictures who underwent primary stent placement between October 2001 and March 2010. Covered biliary self-expandable metal stents (SEMSs) were removed in 39 of these patients, and 36 underwent re-intervention. The patency times, occlusion rates of the first stent and re-intervention, success rates of stent removal, and complications were investigated. Covered SEMSs were placed in 186 patients. The median patency time of the first stent was 352 days. Stent occlusion occurred in 48.9 % of the patients and was mainly caused by debris or food residue (37 %), dislocation (19 %), and migration with hyperplasia (19 %). Stent removal was attempted in 50 patients and was successful without complication in 39 (78 %). Most of the patients in whom stent removal was unsuccessful had migration with hyperplasia. The median patency time of the second stent was 263 days. The stent patency time did not significantly differ between the first and the second stent. Covered SEMSs could be safely removed at the time of stent occlusion. Patency rates were similar for initial stent placement and re-intervention. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Technical Reports Server (NTRS)
Fibiger, Dorothy L.; McDuffie, Erin E.; Dube, William P.; Aikin, Kenneth C.; Lopez-Hilifiker, Felipe D.; Lee, Ben H.; Green, Jaime R.; Fiddler, Marc N.; Holloway, John S.; Ebben, Carlena;
2018-01-01
Nitric oxide (NO) is emitted in large quantities from coal-�burning power plants. During the day, the plumes from these sources are efficiently mixed into the boundary layer, while at night, they may remain concentrated due to limited vertical mixing during which they undergo horizontal fanning. At night, the degree to which NO is converted to HNO3 and therefore unable to participate in next-�day ozone (O3) formation depends on the mixing rate of the plume, the composition of power plant emissions, and the composition of the background atmosphere. In this study, we use observed plume intercepts from the Wintertime INvestigation of Transport, Emissions and Reactivity (WINTER) campaign to test sensitivity of overnight NOx removal to the N2O5 loss rate constant, plume mixing rate, background O3, and background levels of volatile organic compounds using a 2-�D box model of power plant plume transport and chemistry. The factor that exerted the greatest control over NOx removal was the loss rate constant of N2O5. At the lowest observed N2O5 loss rate constant, no other combination of conditions converts more than 10 percent of the initial NOx to HNO3. The other factors did not influence NOx removal to the same degree.
NASA Astrophysics Data System (ADS)
Fibiger, Dorothy L.; McDuffie, Erin E.; Dubé, William P.; Aikin, Kenneth C.; Lopez-Hilfiker, Felipe D.; Lee, Ben H.; Green, Jaime R.; Fiddler, Marc N.; Holloway, John S.; Ebben, Carlena; Sparks, Tamara L.; Wooldridge, Paul; Weinheimer, Andrew J.; Montzka, Denise D.; Apel, Eric C.; Hornbrook, Rebecca S.; Hills, Alan J.; Blake, Nicola J.; DiGangi, Josh P.; Wolfe, Glenn M.; Bililign, Solomon; Cohen, Ronald C.; Thornton, Joel A.; Brown, Steven S.
2018-01-01
Nitric oxide (NO) is emitted in large quantities from coal-burning power plants. During the day, the plumes from these sources are efficiently mixed into the boundary layer, while at night, they may remain concentrated due to limited vertical mixing during which they undergo horizontal fanning. At night, the degree to which NO is converted to HNO3 and therefore unable to participate in next-day ozone (O3) formation depends on the mixing rate of the plume, the composition of power plant emissions, and the composition of the background atmosphere. In this study, we use observed plume intercepts from the Wintertime INvestigation of Transport, Emissions and Reactivity campaign to test sensitivity of overnight NO
Steam and air co-injection in removing residual TCE in unsaturated layered sandy porous media.
Peng, Sheng; Wang, Ning; Chen, Jiajun
2013-10-01
Steam and air co-injection is a promising technique for volatile and semi-volatile organic contaminant remediation in heterogeneous porous media. In this study, removal of trichloroethene (TCE) with steam-air co-injection was investigated through a series of 2D sandbox experiments with different layered sand structures, and through numerical simulations. The results show that a layered structure with coarse sand, in which steam and air convection are relatively rapid, resulted in a higher removal rate and a larger removal ratio than those observed in an experiment using finer sand; however, the difference was not significant, and the removal ratios from three experiments ranged from 85% to 94%. Slight downward movement of TCE was observed for Experiment 1 (TCE initially in a fine sand zone encased in a coarse sand), while no such movement was observed for Experiment 2 (TCE initially in two fine sand layers encased in a coarse sand) or 3 (TCE initially in a silty sand zone encased in a coarse sand). Simulations show accumulation of TCE at the interface of the layered sands, which indicates a capillary barrier effect in restraining the downward movement of TCE. This effect is illustrated further by a numerical experiment with homogeneous coarse sand, in which continuous downward TCE movement to the bottom of the sandbox was simulated. Another numerical experiment with higher water saturation was also conducted. The results illustrate a complicated influence of water saturation on TCE removal in a layered sand structure. Published by Elsevier B.V.
NASA Technical Reports Server (NTRS)
Gordils-Striker, Nilda E.; Colon, Guillermo
2003-01-01
The removal of sodium chloride (NaCl) from human urine using a six-compartment electrodialysis cell with batch recirculation mode of operation for use in advanced life support systems (ALSS) was studied. From the results obtained, batch recirculation at constant applied voltage yields high values (approximately 94% of NaCl removal. Based on the results, the initial rate of NaCl removal was correlated to a power function of the applied voltage: -r=2.0 x 10(-4)E(3.8). With impedance spectroscopy methods, it was also found that the anion membranes were more affected by fouling with an increase of the ohmic resistance of almost 11% compared with 7.4% for the cationic ones.
Nguyen, D Duc; Ngo, H Hao; Guo, W; Nguyen, T Thanh; Chang, Soon W; Jang, A; Yoon, Yong S
2016-09-01
This paper evaluated a novel pilot scale electrocoagulation (EC) system for improving total phosphorus (TP) removal from municipal wastewater. This EC system was operated in continuous and batch operating mode under differing conditions (e.g. flow rate, initial concentration, electrolysis time, conductivity, voltage) to evaluate correlative phosphorus and electrical energy consumption. The results demonstrated that the EC system could effectively remove phosphorus to meet current stringent discharge standards of less than 0.2mg/L within 2 to 5min. This target was achieved in all ranges of initial TP concentrations studied. It was also found that an increase in conductivity of solution, voltages, or electrolysis time, correlated with improved TP removal efficiency and reduced specific energy consumption. Based on these results, some key economic considerations, such as operating costs, cost-effectiveness, product manufacturing feasibility, facility design and retrofitting, and program implementation are also discussed. This EC process can conclusively be highly efficient in a relatively simple, easily managed, and cost-effective for wastewater treatment system. Copyright © 2016 Elsevier B.V. All rights reserved.
Optimal conditions for bioremediation of oily seawater.
Zahed, Mohammad Ali; Aziz, Hamidi Abdul; Isa, Mohamed Hasnain; Mohajeri, Leila; Mohajeri, Soraya
2010-12-01
To determine the influence of nutrients on the rate of biodegradation, a five-level, three-factor central composite design (CCD) was employed for bioremediation of seawater artificially contaminated with crude oil. Removal of total petroleum hydrocarbons (TPH) was the dependent variable. Samples were extracted and analyzed according to US-EPA protocols. A significant (R(2)=0.9645, P<0.0001) quadratic polynomial mathematical model was generated. Removal from samples not subjected to optimization and removal by natural attenuation were 53.3% and 22.6%, respectively. Numerical optimization was carried out based on desirability functions for maximum TPH removal. For an initial crude oil concentration of 1g/L supplemented with 190.21 mg/L nitrogen and 12.71 mg/L phosphorus, the Design-Expert software predicted 60.9% hydrocarbon removal; 58.6% removal was observed in a 28-day experiment. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Cutiongco, Eric C.; Chung, Yip-Wah
1994-07-01
A method for predicting scuffing failure based on the competitive kinetics of oxide formation and removal has been developed and applied to the sliding of AISI 52100 steel on steel with poly-alpha-olefin as the lubricant. Oxide formation rates were determining using static oxidation tests on coupons of 52100 steel covered with poly-alpha-olefin at temperatures of 140 C to 250 C. Oxide removal rates were determined at different combinations of initial average nominal contact pressures (950 MPa to 1578 MPa) and sliding velocities (0.4 m/s to 1.8 m/s) using a ball-on-disk vacuum tribotester. The nominal asperity flash temperatures generated during the wear tests were calculated and the temperatures corresponding to the intersection of the the Arrhenius plots of oxide formation and removal rates were determined and taken as the critical failure temperatures. The pressure-velocity failure transition diagram was constructed by plotting the critical failure temperatures along isotherms of average nominal asperity flash temperatures calculated at different combinations of contact stress and sliding speed. The predicted failure transition curve agreed well with experimental scuffing data.
Chang, Ling; Zhang, Yongming; Gan, Lu; Xu, Hua; Yan, Ning; Liu, Rui; Rittmann, Bruce E
2014-07-01
Biofilm biodegradation was coupled with ultra-violet photolysis using the internal loop photobiodegradation reactor for degradation of quinoline. Three protocols-photolysis alone (P), biodegradation alone (B), and intimately coupled photolysis and biodegradation (P&B)-were used for degradation of quinoline in batch and continuous-flow experiments. For a 1,000 mg/L initial quinoline concentration, the volumetric removal rate for quinoline was 38 % higher with P&B than with B in batch experiments, and the P&B kinetics were the sum of kinetics from the P and B experiments. Continuous-flow experiments with an influent quinoline concentration of 1,000 mg/L also gave significantly greater quinoline removal in P&B, and the quinoline-removal kinetics for P&B were approximately equal to the sum of the removal kinetics for P and B. P&B similarly increased the rate and extent of quinoline mineralization, for which the kinetics for P&B were nearly equal to the sum of kinetics for P and B. These findings support that the rate-limiting step for mineralization was transformation of quinoline, which was accelerated by the simultaneous action of photolysis and biodegradation.
The Effects of Ashe Juniper on Groundwater Recharge in the Edwards Aquifer
NASA Astrophysics Data System (ADS)
Bazan, R. A.; Wilcox, B. P.; Munster, C. L.; Gregory, L. F.
2008-12-01
Understanding groundwater recharge rates has direct relevance for management of the Edwards Aquifer, which serves as the main source of fresh water for the city of San Antonio and surrounding communities. As population around San Antonio continues to grow, so does the demand for water and the stress placed on the aquifer. A method that is commonly believed to augment water yields is brush management. Recently on the Edwards Plateau decreasing streamflow has coincided with increasing juniper density. This has led many to believe that removing juniper would increase available water. Due to its karstic nature, the recharge zone of the Edwards Aquifer is assumed to be a prime location for augmenting water yields through vegetation manipulation. This study assesses the dynamics of recharge and the effects of manipulating surface vegetation. To accomplish this, a shallow cave located in the Edwards Aquifer recharge zone in San Antonio, Texas was instrumented to monitor drip recharge in response to simulated rainfall events. In 2004, simulations were conducted over the cave to measure recharge rates with a dense Ashe juniper canopy. The data and observations from the initial simulations were used to establish a baseline with the juniper in place. In March 2008 the juniper stand was cleared and the rainfall simulations were reproduced in June and July 2008. Results initially indicated that removing the juniper decreases recharge, however, surface runoff was significantly increased. From the results we can conclude that the dynamics of recharge are affected initially following removal of juniper.
Research on the Treatment of Aluminum Alloy Chemical Milling Wastewater with Fenton Process
NASA Astrophysics Data System (ADS)
Zong-liang, Huang; Ru, Li; Peng, Luo; Jun-li, Gu
2018-03-01
The aluminum alloy chemical milling wastewater was treated by Fenton method. The effect of pH value, reaction time, rotational speed, H2O2 dosage, Fe2+ dosage and the molar ratio between H2O2 and Fe2+ on the COD removal rate of aluminum alloy chemical milling wastewater were investigated by single factor experiment and orthogonal experiment. The results showed that the optimum operating conditions for Fenton oxidation were as follows: the initial pH value was 3, the rotational speed was 250r/min, the molar ratio of H2O2 and Fe2+ was 8, the reaction time was 90 min. Under the optimum conditions, the removal rate of the wastewater’s COD is about 72.36%. In the reaction kinetics that aluminum alloy chemical milling wastewater was oxidized and degraded by Fenton method under the optimum conditions, the reaction sequence of the initial COD was 0.8204.
Degradation properties of protein and carbohydrate during sludge anaerobic digestion.
Yang, Guang; Zhang, Panyue; Zhang, Guangming; Wang, Yuanyuan; Yang, Anqi
2015-09-01
Degradation of protein and carbohydrate is vital for sludge anaerobic digestion performance. However, few studies focused on degradation properties of protein and carbohydrate. This study investigated detailed degradation properties of sludge protein and carbohydrate in order to gain insight into organics removal during anaerobic digestion. Results showed that carbohydrate was more efficiently degraded than protein and was degraded prior to protein. The final removal efficiencies of carbohydrate and protein were 49.7% and 32.2%, respectively. The first 3 days were a lag phase for protein degradation since rapid carbohydrate degradation in this phase led to repression of protease formation. Kinetics results showed that, after initial lag phase, protein degradation followed the first-order kinetic with rate constants of 0.0197 and 0.0018 d(-1) during later rapid degradation phase and slow degradation phase, respectively. Carbohydrate degradation also followed the first-order kinetics with a rate constant of 0.007 d(-1) after initial quick degradation phase. Copyright © 2015 Elsevier Ltd. All rights reserved.
Attrition-enhanced sulfur capture by limestone particles in fluidized beds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saastamoinen, J.J.; Shimizu, T.
2007-02-14
Sulfur capture by limestone particles in fluidized beds is a well-established technology. The underlying chemical and physical phenomena of the process have been extensively studied and modeled. However, most of the studies have been focused on the relatively brief initial stage of the process, which extends from a few minutes to hours, yet the residence time of the particles in the boiler is much longer. Following the initial stage, a dense product layer will be formed on the particle surface, which decreases the rate of sulfur capture and the degree of utilization of the sorbent. Attrition can enhance sulfur capturemore » by removing this layer. A particle model for sulfur capture has been incorporated with an attrition model. After the initial stage, the rate of sulfur capture stabilizes, so that attrition removes the surface at the same rate as diffusion and chemical reaction produces new product in a thin surface layer of a particle. An analytical solution for the conversion of particles for this regime is presented. The solution includes the effects of the attrition rate, diffusion, chemical kinetics, pressure, and SO{sub 2} concentration, relative to conversion-dependent diffusivity and the rate of chemical reaction. The particle model results in models that describe the conversion of limestone in both fly ash and bottom ash. These are incorporated with the residence time (or reactor) models to calculate the average conversion of the limestone in fly ash and bottom ash, as well as the efficiency of sulfur capture. Data from a large-scale pressurized fluidized bed are compared with the model results.« less
Impact of microbial activity on the hydraulic properties of fractured chalk.
Arnon, Shai; Adar, Eilon; Ronen, Zeev; Yakirevich, Alexander; Nativ, Ronit
2005-02-01
The impact of microbial activity on fractured chalk transmissivity was investigated on a laboratory scale. Long-term experiments were conducted on six fractured chalk cores (20 cm diameter, 23-44 cm long) containing a single natural fracture embedded in a porous matrix. Biodegradation experiments were conducted under various conditions, including several substrate and oxygen concentrations and flow rates. 2,4,6-Tribromophenol (TBP) was used as a model contaminant (substrate). TBP biodegradation efficiency depended mainly on the amount of oxygen. However, under constant oxygen concentration at the core inlet, elevating the flow rates increased the removal rate of TBP. Transmissivity reduction was clearly related to TBP removal rate, following an initial slow decline and a further sharp decrease with time. The fracture's transmissivity was reduced by as much as 97% relative to the initial value, with no leveling off of the clogging process. For the most extreme cases, reductions of 262 and 157 microm in the equivalent hydraulic apertures were recorded for fractures with initial apertures of 495 and 207 microm, respectively. The reductions in fracture transmissivity occurred primarily because of clogging by bacterial cells and extracellular polymeric substances (EPS) produced by the bacteria. Most of the biodegradation activity was concentrated near the fracture inlet, where the most suitable biodegradation conditions (nutrients and oxygen) prevailed, suggesting that the clogging had occurred in that vicinity. The clogging must have changed the structure of the fracture void, thereby reducing the active volume participating in flow and transport processes. This phenomenon caused accelerated transport of non-reactive tracers and doubled the fracture's dispersivity under constant flow rates.
Ozone and photocatalytic processes to remove the antibiotic sulfamethoxazole from water.
Beltrán, Fernando J; Aguinaco, Almudena; García-Araya, Juan F; Oropesa, Ana
2008-08-01
In this study, water containing the pharmaceutical compound sulfamethoxazole (SMT) was subjected to the various treatments of different oxidation processes involving ozonation, and photolysis and catalysis under different experimental conditions. Removal rates of SMT and total organic carbon (TOC), from experiments of simple UVA radiation, ozonation (O(3)), catalytic ozonation (O(3)/TiO(2)), ozone photolysis (O(3)/UVA), photocatalytic oxidation (O(2)/TiO(2)/UVA) and photocatalytic ozonation (O(3)/UVA/TiO(2)), have been compared. Photocatalytic ozonation leads to the highest SMT removal rate (pH 7 in buffered systems, complete removal is achieved in less than 5min) and total organic carbon (in unbuffered systems, with initial pH=4, 93% TOC removal is reached). Also, lowest ozone consumption per TOC removed and toxicity was achieved with the O(3)/UVA/TiO(2) process. Direct ozone and free radical reactions were found to be the principal mechanisms for SMT and TOC removal, respectively. In photocatalytic ozonation, with buffered (pH 7) aqueous solutions phosphates (buffering salts) and accumulation of bicarbonate scavengers inhibit the reactions completely on the TiO(2) surface. As a consequence, TOC removal diminishes. In all cases, hydrogen peroxide plays a key role in TOC mineralization. According to the results obtained in this work the use of photocatalytic ozonation is recommended to achieve a high mineralization degree of water containing SMT type compounds.
Potential demographic and genetic effects of a sterilant applied to wild horse mares
Roelle, James E.; Oyler-McCance, Sara J.
2015-01-01
Wild horse populations on western ranges can increase rapidly, resulting in the need for the Bureau of Land Management (BLM) to remove animals in order to protect the habitat that horses share with numerous other species. As an alternative to removals, BLM has sought to develop a long-term, perhaps even permanent, contraceptive to aid in reducing population growth rates. With long-term (perhaps even permanent) efficacy of contraception, however, comes increased concern about the genetic health of populations and about the potential for local extirpation. We used simulation modeling to examine the potential demographic and genetic consequences of applying a mare sterilant to wild horse populations. Using the VORTEX software package, we modeled the potential effects of a sterilant on 70 simulated populations having different initial sizes (7 values), growth rates (5 values), and genetic diversity (2 values). For each population, we varied the treatment rate of mares from 0 to 100 percent in increments of 10 percent. For each combination of these treatment levels, we ran 100 stochastic simulations, and we present the results in the form of tables and graphs showing mean population size after 20 years, mean number of removals after 20 years, mean probability of extirpation after 50 years, and mean heterozygosity after 50 years. By choosing one or two combinations of initial population size, population growth rate, and genetic diversity that best represent a herd of interest, a manager can assess the likely effects of a contraceptive program by examining the output tables and graphs representing the selected conditions.
High renesting rates in arctic-breeding Dunlin (Calidris alpina): A clutch-removal experiment
Gates, H. River; Lanctot, Richard B.; Powell, Abby N.
2013-01-01
The propensity to replace a clutch is a complex component of avian reproduction and poorly understood. We experimentally removed clutches from an Arctic-breeding shorebird, the Dunlin (Calidris alpina arcticola), during early and late stages of incubation to investigate replacement clutch rates, renesting interval, and mate and site fidelity between nesting attempts. In contrast to other Arctic studies, we documented renesting by radiotracking individuals to find replacement clutches. We also examined clutch size and mean egg volume to document changes in individual females’ investment in initial and replacement clutches. Finally, we examined the influence of adult body mass, clutch volume, dates of clutch initiation and nest loss, and year on the propensity to renest. We found high (82–95%) and moderate (35–50%) rates of renesting for early and late incubation treatments. Renesting intervals averaged 4.7–6.8 days and were not different for clutches removed early or late in incubation. Most pairs remained together for renesting attempts. Larger females were more likely to replace a clutch; female body mass was the most important parameter predicting propensity to renest. Clutches lost later in the season were less likely to be replaced. We present evidence that renesting is more common in Arctic-breeding shorebirds than was previously thought, and suggest that renesting is constrained by energetic and temporal factors as well as mate availability. Obtaining rates of renesting in species breeding at different latitudes will help determine when this behavior is likely to occur; such information is necessary for demographic models that include individual and population-level fecundity estimates.
Hydrodechlorination of TCE in a circulated electrolytic column at high flow rate.
Fallahpour, Noushin; Yuan, Songhu; Rajic, Ljiljana; Alshawabkeh, Akram N
2016-02-01
Palladium-catalytic hydrodechlorination of trichloroethylene (TCE) by cathodic H2 produced from water electrolysis has been tested. For a field in-well application, the flow rate is generally high. In this study, the performance of Pd-catalytic hydrodechlorination of TCE using cathodic H2 is evaluated under high flow rate (1 L min(-1)) in a circulated column system, as expected to occur in practice. An iron anode supports reduction conditions and it is used to enhance TCE hydrodechlorination. However, the precipitation occurs and high flow rate was evaluated to minimize its adverse effects on the process (electrode coverage, clogging, etc.). Under the conditions of 1 L min(-1) flow, 500 mA current, and 5 mg L(-1) initial TCE concentration, removal efficacy using iron anodes (96%) is significantly higher than by mixed metal oxide (MMO) anodes (66%). Two types of cathodes (MMO and copper foam) in the presence of Pd/Al2O3 catalyst under various currents (250, 125, and 62 mA) were used to evaluate the effect of cathode materials on TCE removal efficacy. The similar removal efficiencies were achieved for both cathodes, but more precipitation generated with copper foam cathode (based on the experiments done by authors). In addition to the well-known parameters such as current density, electrode materials, and initial TCE concentration, the high velocities of groundwater flow can have important implications, practically in relation to the flush out of precipitates. For potential field application, a cost-effective and sustainable in situ electrochemical process using a solar panel as power supply is being evaluated. Published by Elsevier Ltd.
Hydrodechlorination of TCE in a circulated electrolytic column at high flow rate
Fallahpour, Noushin; Yuan, Songhu; Rajic, Ljiljana; Alshawabkeh, Akram N.
2015-01-01
Palladium-catalytic hydrodechlorination of trichloroethylene (TCE) by cathodic H2 produced from water electrolysis has been tested. For a field in-well application, the flow rate is generally high. In this study, the performance of Pd-catalytic hydrodechlorination of TCE using cathodic H2 is evaluated under high flow rate (1 L min−1) in a circulated column system, as expected to occur in practice. An iron anode supports reduction conditions and it is used to enhance TCE hydrodechlorination. However, the precipitation occurs and high flow rate was evaluated to minimize its advers effects on the process (electrode coverage, clogging, etc.). Under the conditions of 1 L min−1 flow, 500 mA current, and 5 mg L−1 initial TCE concentration, removal efficacy using iron anodes (96%) is significantly higher than by mixed metal oxide (MMO) anodes (66%). Two types of cathodes (MMO and copper foam) in the presence of Pd/Al2O3 catalyst under various currents (250, 125, and 62 mA) were used to evaluate the effect of cathode materials on TCE removal efficacy. The similar removal efficiencies were achieved for both cathodes, but more precipitation generated with copper foam cathode (based on the experiments done by authors). In addition to the well-known parameters such as current density, electrode materials, and initial TCE concentration, the high velocities of groundwater flow can have important implications, practically in relation to the flush out of precipitates. For potential field application, a cost-effective and sustainable in situ electrochemical process using a solar panel as power supply is being evaluated. PMID:26344148
Potential use of Lemna minor for the phytoremediation of isoproturon and glyphosate.
Dosnon-Olette, Rachel; Couderchet, Michel; Oturan, Mehmet A; Oturan, Nihal; Eullaffroy, Philippe
2011-07-01
Pesticides are being detected in water bodies on an increasingly frequent basis. The present study focused on toxicity and phytoremediation potential of aquatic plants to remove phytosanitary products from contaminated water. We investigated the capacity of Lemna minor (L. minor) to eliminate two herbicides isoproturon and glyphosate from their medium. Since phytoremediation relies on healthy plants, pesticide toxicity was evaluated by exposing plants to 5 concentrations (0-20 microg L(-1) for isoproturon and 0-120 microg L(-1) for glyphosate) in culture media for 4 d using growth rate and chlorophyll a fluorescence as endpoints. At exposure concentrations of 10 microg x L(-1) for isoproturon and 80 microg x L(-1) for glyphosate, effects on growth rate and chlorophyll fluorescence were minor (< 25%), so that this initial concentration was selected to study herbicide removal After a 4-d incubation, removal yields were 25% and 8% for isoproturon and glyphosate, respectively.
Phosphate removal and hemodialysis conditions.
Pohlmeier, R; Vienken, J
2001-02-01
Hyperphosphatemia is frequently found in hemodialysis patients, and the association with an increased risk of mortality has been demonstrated. Other authors have linked hyperphosphatemia to increased cardiovascular mortality. The normalization of phosphate plasma levels is therefore an important goal in the treatment of end-stage renal disease patients. Absorption of phosphate from the food exceeds the elimination through a hemodialysis treatment, and this leads to a chronic phosphate load for the majority of hemodialysis patients. This imbalance should be improved by either a reduction of phosphate absorption or an increased removal of phosphate. A reduction of phosphate absorption can be achieved by reducing the amount of phosphate in the diet or by the administration of phosphate binders. Unfortunately, these measures imply practical difficulties, for example, a lack of patient compliance or other side effects. When considering modifications of the hemodialysis treatment, an essential understanding of the kinetics of dialytic phosphate removal is mandatory. Phosphate is unevenly distributed in different compartments of the body. Only a very small amount of phosphate is present in the easily accessible plasma compartment. The major part of phosphate removed during hemodialysis originates from the cytoplasm of cells. A transfer from intracellular space to the plasma and further from the plasma to the dialysate is necessary. However, if we consider improvement to phosphate removal by dialysis procedures, full dialyzer clearance is effective in only the initial phase of the dialysis treatment. After this initial phase, the transfer rate for phosphate from the intracellular space to the plasma becomes the rate-limiting step for phosphate transport. Attempts to improve this transfer rate have recently been investigated by acidosis correction, but turned out not to be consistently successful. Furthermore, modifications of the treatment schedule have been described in the literature as measures to influence the phosphate balance consistently. Successful improvements of the phosphate balance can be achieved specifically through increasing the frequency of the dialysis treatments.
Yargicoglu, Erin N; Reddy, Krishna R
2017-05-15
Alternate landfill covers designed to enhance microbial methane (CH 4 ) oxidation and reduce the negative impacts of landfill gas emissions on global climate have recently been proposed and investigated. In this study, the use of biochar as a soil amendment is examined in order to assess the feasibility and effectiveness for enhanced CH 4 removal in landfill covers when incorporated under high compaction conditions and relatively low soil moisture. Four different cover configurations were tested in large soil columns for ∼510 days and potential CH 4 oxidation rates were determined following long-term incubation in small batch assays. Cover designs tested include: a thin biochar layer at 15-18 cm; 2% mixed soil-biochar layer at 20-40 cm; 2% mixed soil-uncharred wood pellets at 20-40 cm; and soil obtained from intermediate cover at an active landfill site. The placement of a thin biochar layer in the cover significantly impacted moisture distribution and infiltration, which in turn affected CH 4 oxidation potential with depth. An increase in CH 4 removal rates was observed among all columns over the 500 day incubation period, with steady-state CH 4 removal efficiencies ranging from ∼60 to 90% in the final stages of incubation (inlet load ∼80 g CH 4 m -2 d -1 ). The thin biochar layer had the lowest average removal efficiency as a result of reduced moisture availability below the biochar layer. The addition of 2% biochar to soil yielded similar CH 4 oxidation rates in terminal assays as the 2% uncharred wood pellet amendment. CH 4 oxidation rates in terminal assays were positively correlated with soil moisture, which was affected by the materials' water holding capacity. The high water holding capacity of biochar led to higher oxidation rates within the thin biochar layer, supporting the initial hypothesis that biochar may confer more favorable physical conditions for methanotrophy. Ultimate performance was apparently affected by soil type and CH 4 exposure history, with the highest oxidation rates observed in the unamended field soil with higher initial methanotrophic activity. Copyright © 2017 Elsevier Ltd. All rights reserved.
Effects of water chemistry on arsenic removal from drinking water by electrocoagulation.
Wan, Wei; Pepping, Troy J; Banerji, Tuhin; Chaudhari, Sanjeev; Giammar, Daniel E
2011-01-01
Exposure to arsenic through drinking water poses a threat to human health. Electrocoagulation is a water treatment technology that involves electrolytic oxidation of anode materials and in-situ generation of coagulant. The electrochemical generation of coagulant is an alternative to using chemical coagulants, and the process can also oxidize As(III) to As(V). Batch electrocoagulation experiments were performed in the laboratory using iron electrodes. The experiments quantified the effects of pH, initial arsenic concentration and oxidation state, and concentrations of dissolved phosphate, silica and sulfate on the rate and extent of arsenic removal. The iron generated during electrocoagulation precipitated as lepidocrocite (γ-FeOOH), except when dissolved silica was present, and arsenic was removed by adsorption to the lepidocrocite. Arsenic removal was slower at higher pH. When solutions initially contained As(III), a portion of the As(III) was oxidized to As(V) during electrocoagulation. As(V) removal was faster than As(III) removal. The presence of 1 and 4 mg/L phosphate inhibited arsenic removal, while the presence of 5 and 20 mg/L silica or 10 and 50 mg/L sulfate had no significant effect on arsenic removal. For most conditions examined in this study, over 99.9% arsenic removal efficiency was achieved. Electrocoagulation was also highly effective at removing arsenic from drinking water in field trials conducted in a village in Eastern India. By using operation times long enough to produce sufficient iron oxide for removal of both phosphate and arsenate, the performance of the systems in field trials was not inhibited by high phosphate concentrations. Copyright © 2010 Elsevier Ltd. All rights reserved.
Tan, Dina; Zeng, Honghu; Liu, Jie; Yu, Xiaozhang; Liang, Yanpeng; Lu, Lanjing
2013-07-01
The kinetics of the degradation of trace nitrobenzene (NB) by a granular activated carbon (GAC) enhanced microwave (MW)/hydrogen peroxide (H202) system was studied. Effects of pH, NB initial concentration and tert-butyl alcohol on the removal efficiency were examined. It was found that the reaction rate fits well to first-order reaction kinetics in the MW/GAC/H202 process. Moreover, GAC greatly enhanced the degradation rate of NB in water. Under a given condition (MW power 300 W, H202 dosage 10 mg/L, pH 6.85 and temperature (60 +/- 5)degrees C), the degradation rate of NB was 0.05214 min-1when 4 g/L GAC was added. In general, alkaline pH was better for NB degradation; however, the optimum pH was 8.0 in the tested pH value range of 4.0-12.0. At H202 dosage of 10 mg/L and GAC dosage of 4 g/L, the removal of NB was decreased with increasing initial concentrations of NB, indicating that a low initial concentration was beneficial for the degradation of NB. These results indicated that the MW/GAC/H202 process was effective for trace NB degradation in water. Gas chromatography-mass spectrometry analysis indicated that a hydroxyl radical addition reaction and dehydrogenation reaction enhanced NB degradation.
DOT National Transportation Integrated Search
2016-03-01
The Maine Department of Transportation (MaineDOT) has removed 25 rivets from an existing, older truss bridge. : Many such truss bridges have low rating factors as determined using Federal Highway Administration (FHWA) : and the American Association o...
Rice, K.G.; Waddle, J.H.; Miller, M.W.; Crockett, M.E.; Mazzotti, F.J.; Percival, H.F.
2011-01-01
Florida is home to several introduced animal species, especially in the southern portion of the state. Most introduced species are restricted to the urban and suburban areas along the coasts, but some species, like the Cuban Treefrog (Osteopilus septentrionalis), are locally abundant in natural protected areas. Although Cuban Treefrogs are known predators of native treefrog species as both adults and larvae, no study has demonstrated a negative effect of Cuban Treefrogs on native treefrog survival, abundance, or occupancy rate. We monitored survival, capture probability, abundance, and proportion of sites occupied by Cuban Treefrogs and two native species, Green Treefrogs (Hyla cinerea) and Squirrel Treefrogs (Hyla squirella), at four sites in Everglades National Park in southern Florida with the use of capture–mark–recapture techniques. After at least 5 mo of monitoring all species at each site we began removing every Cuban Treefrog captured. We continued to estimate survival, abundance, and occupancy rates of native treefrogs for 1 yr after the commencement of Cuban Treefrog removal. Mark–recapture models that included the effect of Cuban Treefrog removal on native treefrog survival did not have considerable Akaike's Information Criterion (AIC) weight, although capture rates of native species were generally very low prior to Cuban Treefrog removal. Estimated abundance of native treefrogs did increase after commencement of Cuban Treefrog removal, but also varied with the season of the year. The best models of native treefrog occupancy included a Cuban Treefrog removal effect at sites with high initial densities of Cuban Treefrogs. This study demonstrates that an introduced predator can have population-level effects on similar native species.
Fu, Lichun; Shuang, Chendong; Liu, Fuqiang; Li, Aimin; Li, Yan; Zhou, Yang; Song, Haiou
2014-05-15
A novel magnetic weak acid resin NDMC was self-synthesized for the removal of Cu(2+) from aqueous solutions. NDMC showed superior properties on the removal of Cu(2+) compared to commercial resins C106 and IRC-748, which was deeply investigated by adsorption isotherms and kinetic tests. The equilibrium adsorption amount of Cu(2+) onto NDMC (267.2mg/g) was almost twice as large as that onto IRC-748 (120.0mg/g). The adsorption kinetics of Cu(2+) onto the three resins fitted well with the pseudo-second-order equation. The initial adsorption rate h of NDMC was about 4 times that of C106 and nearly 8 times that of IRC-748 at the initial concentration of 500mg/L. External surface area was determined to be the key factor in rate-controlling by further analyzing the adsorption thermodynamics, kinetics parameters and physicochemical properties of the resins. NDMC resin with the smallest bead radius possessed the largest external surface and therefore exhibited the fastest kinetics. The adsorption amount of Cu(2+) onto NDMC was not influenced as the concentration of Na(+) increased from 1.0 to 10.0mM/L. Dilute HCl solution could effectively desorb Cu(2+). NDMC demonstrated high stability during 10 adsorption/desorption cycles, showing great potential in the rapid removal of Cu(2+) from wastewater. Copyright © 2014 Elsevier B.V. All rights reserved.
Biological Cr(VI) removal using bio-filters and constructed wetlands.
Michailides, Michail K; Sultana, Mar-Yam; Tekerlekopoulou, Athanasia G; Akratos, Christos S; Vayenas, Dimitrios V
2013-01-01
The bioreduction of hexavalent chromium from aqueous solution was carried out using suspended growth and packed-bed reactors under a draw-fill operating mode, and horizontal subsurface constructed wetlands. Reactors were inoculated with industrial sludge from the Hellenic Aerospace Industry using sugar as substrate. In the suspended growth reactors, the maximum Cr(VI) reduction rate (about 2 mg/L h) was achieved for an initial concentration of 12.85 mg/L, while in the attached growth reactors, a similar reduction rate was achieved even with high initial concentrations (109 mg/L), thus confirming the advantage of these systems. Two horizontal subsurface constructed wetlands (CWs) pilot-scale units were also built and operated. The units contained fine gravel. One unit was planted with common reeds and one was kept unplanted. The mean influent concentrations of Cr(VI) were 5.61 and 5.47 mg/L for the planted and unplanted units, respectively. The performance of the planted CW units was very effective as mean Cr(VI) removal efficiency was 85% and efficiency maximum reached 100%. On the contrary, the unplanted CW achieved very low Cr(VI) removal with a mean value of 26%. Both attached growth reactors and CWs proved efficient and viable means for Cr(VI) reduction.
Nasrullah, Asma; Khan, Hizbullah; Khan, Amir Sada; Man, Zakaria; Muhammad, Nawshad; Khan, Muhammad Irfan; Abd El-Salam, Naser M.
2015-01-01
The ash of C. polygonoides (locally called balanza) was collected from Lakki Marwat, Khyber Pakhtunkhwa, Pakistan, and was utilized as biosorbent for methylene blue (MB) removal from aqueous solution. The ash was used as biosorbent without any physical or chemical treatment. The biosorbent was characterized by using various techniques such as Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), and scanning electron microscopy (SEM). The particle size and surface area were measured using particle size analyzer and Brunauer-Emmett-Teller equation (BET), respectively. The SEM and BET results expressed that the adsorbent has porous nature. Effects of various conditions such as initial concentration of methylene blue (MB), initial pH, contact time, dosage of biosorbent, and stirring rate were also investigated for the adsorption process. The rate of the adsorption of MB on biomass sample was fast, and equilibrium has been achieved within 1 hour. The kinetics of MB adsorption on biosorbent was studied by pseudo-first- and pseudo-second-order kinetic models and the pseudo-second-order has better mathematical fit with correlation coefficient value (R 2) of 0.999. The study revealed that C. polygonoides ash proved to be an effective, alternative, inexpensive, and environmentally benign biosorbent for MB removal from aqueous solution. PMID:25705714
Najafpoor, Ali Asghar; Jonidi Jafari, Ahmad; Hosseinzadeh, Ahmad; Khani Jazani, Reza; Bargozin, Hasan
2018-01-01
Treatment with a non-thermal plasma (NTP) is a new and effective technology applied recently for conversion of gases for air pollution control. This research was initiated to optimize the efficient application of the NTP process in benzene, toluene, ethyl-benzene, and xylene (BTEX) removal. The effects of four variables including temperature, initial BTEX concentration, voltage, and flow rate on the BTEX elimination efficiency were investigated using response surface methodology (RSM). The constructed model was evaluated by analysis of variance (ANOVA). The model goodness-of-fit and statistical significance was assessed using determination coefficients (R 2 and R 2 adj ) and the F-test. The results revealed that the R 2 proportion was greater than 0.96 for BTEX removal efficiency. The statistical analysis demonstrated that the BTEX removal efficiency was significantly correlated with the temperature, BTEX concentration, voltage, and flow rate. Voltage was the most influential variable affecting the dependent variable as it exerted a significant effect (p < 0.0001) on the response variable. According to the achieved results, NTP can be applied as a progressive, cost-effective, and practical process for treatment of airstreams polluted with BTEX in conditions of low residence time and high concentrations of pollutants.
Kennison, Rachel L; Kamer, Krista; Fong, Peggy
2011-06-01
We quantified the effects of initial macroalgal tissue nitrogen (N) status (depleted and enriched) and varying pulses of nitrate (NO 3 - ) concentration on uptake and storage of nitrogen in Ulva intestinalis L. and Ulva expansa (Setch.) Setch. et N. L. Gardner using mesocosms modeling shallow coastal estuaries in Mediterranean climates. Uptake of NO 3 - (μmol · g dry weight [dwt] -1 · h -1 ) was measured as loss from the water after 1, 2, 4, 8, 12, and 24 h and storage as total tissue nitrogen (% dwt) and nitrate (ppm). Both species of algae exhibited a high affinity for NO 3 - across all N pulses and initial tissue contents. There was greater NO 3 - removal from the water for depleted than enriched algae across all time intervals. In the low-N-pulse treatment, U. intestinalis and U. expansa removed all measurable NO 3 - within 8 and 12 h, respectively, and in the medium and high treatments, removal was high and then decreased over time. Maximum mean uptake rates of nitrate were greater for U. expansa (∼300 μmol · g dwt -1 · h -1 ) than U. intestinalis (∼100 μmol · g dwt -1 · h -1 ); however, uptake rates were highly variable over time. Overall, U. expansa uptake rates were double those of U. intestinalis. Maximum tissue NO 3 - for U. expansa was >1,000 ppm, five times that of U. intestinalis, suggesting that U. expansa has a greater storage capacity in this cellular pool. These results showed that opportunistic green algae with differing tissue nutrient histories were able to efficiently remove nitrate from the water across a wide range of N pulses; thus, both are highly adapted to proliferate in estuarine environments with pulsed nutrient supplies. © 2011 Phycological Society of America.
Biochar from Chinese herb residues as adsorbent for toxic metals removal
NASA Astrophysics Data System (ADS)
Liu, Guocheng; Huang, Yu; Xu, Lina
2017-04-01
Two biochars were prepared form Chinese herb residues by slow pyrolysis at 300 °C and 600 °C (CHR300 and CHR600) for removing two toxic metal ions (Pb2+ and Cd2+) from aqueous phase. In this study, both Pb2+ and Cd2+ were effectively immobilized by CHR300 and CHR600 from water. For an initial concentration of Pb2+ and Cd2+ (C 0 = 10 mg/L), the removal rate by CHR300 and CHR600 were all greater than 90.0% at a solid:liquid ratio of 50 mg biochar in 10 mL solution. For C 0 of the two toxic metals was 100 mg/L, the Pb2+ removal by CHR600 was significantly stronger than that by CHR300, but there was no significant difference of the removal rate of Cd2+ between CHR300 and CHR600. Moreover, the removal rate of Pb2+ by CHR300 and CHR600 was both markedly greater than that of Cd2+, indicating that the biochars had stronger adsorption favorite for Pb2+ than Cd2+. The SEM-EDX data of the biochars after the toxic metals sorption drew strong evidences on the Pb2+ and Cd2+ immobilization by CHR300 and CHR600. The existing of phosphorus (P) and sulphur (S) in CHR300 and CHR600 implied that the heavy metals might be removed by forming Pb/Cd-P and Pb/Cd-S precipitates. These results suggested that the biochars from Chinese herb residues would be likely to be good adsorbents for Pb2+ and Cd2+ removal in water.
Long-term performance of passive materials for removal of ozone from indoor air.
Cros, C J; Morrison, G C; Siegel, J A; Corsi, R L
2012-02-01
The health effects associated with exposure to ozone range from respiratory irritation to increased mortality. In this paper, we explore the use of three green building materials and an activated carbon (AC) mat that remove ozone from indoor air. We studied the effects of long-term exposure of these materials to real environments on ozone removal capability and pre- and post-ozonation emissions. A field study was completed over a 6-month period, and laboratory testing was intermittently conducted on material samples retrieved from the field. The results show sustained ozone removal for all materials except recycled carpet, with greatest ozone deposition velocity for AC mat (2.5-3.8 m/h) and perlite-based ceiling tile (2.2-3.2 m/h). Carbonyl emission rates were low for AC across all field sites. Painted gypsum wallboard and perlite-based ceiling tile had similar overall emission rates over the 6-month period, while carpet had large initial emission rates of undesirable by-products that decayed rapidly but remained high compared with other materials. This study confirms that AC mats and perlite-based ceiling tile are viable surfaces for inclusion in buildings to remove ozone without generating undesirable by-products. PRACTICAL IMPLICATIONS The use of passive removal materials for ozone control could decrease the need for, or even render unnecessary, active but energy consuming control solutions. In buildings where ozone should be controlled (high outdoor ozone concentrations, sensitive populations), materials specifically designed or selected for removing ozone could be implemented, as long as ozone removal is not associated with large emissions of harmful by-products. We find that activated carbon mats and perlite-based ceiling tiles can provide substantial, long-lasting, ozone control. © 2011 John Wiley & Sons A/S.
Ji, Jing; Liu, Yang; Yang, Xue-Yuan; Xu, Juan; Li, Xiu-Yan
2018-07-15
The removal of high-concentration rhodamine B (RhB) wastewater was investigated in a three-dimensional electrochemical reactor (3DER) packed with granular activated carbon (GAC) particle electrodes. Response surface methodology (RSM) coupled with grey relational analysis (GRA) was used to evaluate the effects of voltage, initial pH, aeration rate and NaCl dosage on RhB removal and energy consumption of the 3DER. The optimal conditions were determined as voltage 7.25 V, pH 5.99, aeration rate 151.13 mL/min, and NaCl concentration 0.11 mol/L. After 30 min electrolysis, COD removal rate could arrive at 60.13% with an extremely low energy consumption of 6.22 kWh/kg COD. The voltage and NaCl were demonstrated to be the most significant factors affecting the COD removal and energy consumption of 3DER. The intermediates generated during the treatment process were identified and the possible degradation pathway of RhB was proposed. It is worth noting that 3DER also showed an excellent performance in total nitrogen (TN) removal under the optimal condition. The activated chlorine generated from chloride had great contributions to eliminate carbon and nitrogen of RhB wastewater. The treatment effluent had a good biodegradability, which was suitable for subsequent biological treatment. Copyright © 2018 Elsevier Ltd. All rights reserved.
Effect of ultrasonic reactor and auxiliary stirring on oil removal from oily sludge.
Zhao, Xiaofei; Zhang, Xiaoyang; Liu, Lixin; Fan, Lei; Ge, Dan
2017-12-01
In this paper, oily sludge cleaning by using ultrasonic waves was further studied to ensure how the ultrasonic reactor, such as material, bottom thickness, diameter, and auxiliary mixing, effects oil removal from oily sludge. Oily sludge (S) with an initial oil content of 19.29% was mixed with distilled water (W) and treated in an ultrasonic cleaning tank, f = 40,000 Hz at 30°C. This paper was carried out around the ultrasonic reactor, such as material, diameter, and bottom thickness. The results show that acoustic resistance is the main factor affecting the material of the ultrasonic reactor. The larger the diameter of the reaction, the lower the thickness of the S-W mixture of the same quality; the smaller the diffusion attenuation of the ultrasonic wave, the higher the oil removal rate. In this paper, the cleaning efficiency seems to be independent of the bottom thickness of the reactor. This may be due to the hale wavelengths (λ/2) in polyethylene (λ/2 = 2.4 cm) and glass (λ/2 = 7.08 cm) being far greater than the range of bottom thickness. Proper mixing (200 rmin -1 ) can improve the oil removal rate (92.8%), increased by 8.69%, but when the strength is too large, the oil removal rate is reduced.
Chheda, Dhawal; Sorial, George A
2017-07-01
This study investigated the removal of hydrophobic trichloroethylene (TCE) in the presence of methanol (co-metabolite) in a biotrickling filter, which was seeded with fungi at pH4. Starvation was chosen as the biomass control strategy. Two systems, Biofilter I (methanol:TCE 70:30) and Biofilter II (methanol:TCE 80:20) were run in parallel, each with varying composition ratios. The TCE loading rates for both biofilters ranged from 3.22 to 12.88g/m 3 /hr. Depending on the ratio, methanol concentrations varied from 4.08 to 27.95g/m 3 /hr. The performance of the systems was evaluated and compared by calculating removal kinetics, carbon mass balance, efficiencies and elimination capacities. Methanol was observed to enhance TCE removal during the initial loading rate. However, methanol later inhibited TCE degradation above 6.44g TCE/m 3 /hr (Biofilter I) and 3.22g TCE/m 3 /hr (Biofilter II). Conversely, TCE did not impede methanol removal because over 95% methanol elimination was consistently achieved. Overall, Biofilter I was able to outperform Biofilter II due to its greater resistance towards methanol competition. Copyright © 2016. Published by Elsevier B.V.
Removal of arsenic from drinking water using rice husk
NASA Astrophysics Data System (ADS)
Asif, Zunaira; Chen, Zhi
2017-06-01
Rice husk adsorption column method has proved to be a promising solution for arsenic (As) removal over the other conventional methods. The present work investigates the potential of raw rice husk as an adsorbent for the removal of arsenic [As(V)] from drinking water. Effects of various operating parameters such as diameter of column, bed height, flow rate, initial arsenic feed concentration and particle size were investigated using continuous fixed bed column to check the removal efficiency of arsenic. This method shows maximum removal of As, i.e., 90.7 % under the following conditions: rice husk amount 42.5 g; 7 mL/min flow rate in 5 cm diameter column at the bed height of 28 cm for 15 ppb inlet feed concentration. Removal efficiency was increased from 83.4 to 90.7 % by reducing the particle size from 1.18 mm to 710 µm for 15 ppb concentration. Langmuir and Freundlich isotherm models were employed to discuss the adsorption behavior. The effect of different operating parameters on the column adsorption was determined using breakthrough curves. In the present study, three kinetic models Adam-Bohart, Thomas and Yoon-Nelson were applied to find out the saturated concentration, fixed bed adsorption capacity and time required for 50 % adsorbate breakthrough, respectively. At the end, solidification was done for disposal of rice husk.
NASA Astrophysics Data System (ADS)
Regti, Abdelmajid; Laamari, My Rachid; Stiriba, Salah-Eddine; El Haddad, Mohammadine
2017-11-01
In this study, the adsorption potential of activated carbon prepared from Ziziphus mauritiana nuts for the removal of methylene blue (MB) from aqueous solution has been investigated using batch mode experiments. The effects of some operating parameters on the removal dye such as, initial pH (2-12), temperature (298-328 K), initial MB concentration (20-100 mg L-1), and contact time (5-70 min) were investigated. Adsorption kinetic showed that the rate adsorption followed the pseudo-second-order kinetic model. Four adsorption isotherms models were applied to experimental equilibrium data (Langmuir, Freundlich, Redlich-Peterson, and Fritz-Schlunder) and the different constants were calculated using non-linear equations models. Fritz-Schlunder model was found the best one to describe the adsorption process which suggests that the adsorption of MB onto activated carbon derived from Ziziphus mauritiana is heterogeneous with a multilayer. Thermodynamic adsorption showed that the process was endothermic and spontaneous in nature.
Wen, Shan; Liu, Hongyu; He, Huijun; Luo, Le; Li, Xiang; Zeng, Guangming; Zhou, Zili; Lou, Wei; Yang, Chunping
2016-12-01
Two strains of photosynthetic bacteria, Rhodobacter blasticus and Rhodobacter capsulatus, were used in this work to investigate the feasibility of using photosynthetic bacteria for the treatment of anaerobically digested swine wastewater. The effects of crucial factors which influence the pollutants removal efficiency were also examined. Results showed that anaerobically digested swine wastewater could be treated effectively by photosynthetic bacteria. The treatment efficiency was significantly higher by the mixed photosynthetic bacteria than that by any unitary bacterium. The optimal treatment condition by mixed bacteria was inoculation of 10.0%(v/v) of the two bacteria by 1:1, initial pH of 7.0 and initial chemical oxygen demand of 4800mgL -1 . Under these conditions, the removal rate of chemical oxygen demand was 83.3%, which was 19.3% higher than when using Rhodobacter blasticus or 10.6% higher than when using Rhodobacter capsulatus separately. This mixed photosynthetic bacteria achieved high chemical oxygen demand removal and cell yields. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Yoon, Wonduk; Chae, Jinho; Koh, Byoung-Seol; Han, Changhoon
2018-04-01
Aurelia coerulea is a bloom forming jellyfish that first appeared before 1980 in the western and southern Korean seas and which has been blamed for huge economical losses in all fields of marine activities. As a preventive measure to reduce economical losses, polyp removal was undertaken at Lake Shihwa, Lake Saemangeum, and Masan Bay, Korea. In the course of efforts during 2 years to remove polyps, polyps were surveyed, quantified, and removed. In these areas, the initial total polyp abundance was 5.04 × 109 and 46.25% of them were removed; Lake Shihwa the highest rates of removal and Lake Saemangeum the lowest. These efforts to remove polyps prevented the appearance of 1.20 × 109 medusae, corresponding to 78.28 × 106 kg. The cost of polyp removal was evaluated and compared with that of medusae removal. The ratio between the cost of polyp removal and that of medusae removal ranged between 0.78-3.14%, indicating large cost savings for polyp removal undertakings. However, the effect of polyp removal varied from positive to none, and we assumed that the cleared surface for polyp removal, quantity of removed polyp, and existence of polyps' hotspots in neighboring areas were the causes of the non-effectiveness of polyp removal undertakings.
Prevailing Torque Locking Feature in Threaded Fasteners Using Anaerobic Adhesive
NASA Technical Reports Server (NTRS)
Hernandez, Alan; Hess, Daniel P.
2016-01-01
This paper presents results from tests to assess the use of anaerobic adhesive for providing a prevailing torque locking feature in threaded fasteners. Test procedures are developed and tests are performed on three fastener materials, four anaerobic adhesives, and both unseated assembly conditions. Five to ten samples are tested for each combination. Tests for initial use, reuse without additional adhesive, and reuse with additional adhesive are performed for all samples. A 48-hour cure time was used for all initial use and reuse tests. Test data are presented as removal torque versus removal angle with the specification required prevailing torque range added for performance assessment. Percent specification pass rates for the all combinations of fastener material, adhesive, and assembly condition are tabulated and reveal use of anaerobic adhesive as a prevailing torque locking feature is viable. Although not every possible fastener material and anaerobic adhesive combination provides prevailing torque values within specification, any combination can be assessed using the test procedures presented. Reuse without additional anaerobic adhesive generally provides some prevailing torque, and in some cases within specification. Reuse with additional adhesive often provides comparable removal torque data as in initial use.
Ding, Chun-sheng; Ma, Hai-long; Fu, Yang-ping; Zhao, Shi-du; Li, Dong-bing
2015-06-01
The paper used the method of iron copper catalyst reduction to degrade low concentrations of bromochloracetonitrile (BCAN) to lighten the damage to human being, which is a kind of disinfection by-products (DBPs) produced during the chlorination process of drinking water. The removal efficiency of BCAN and its influencing factors were investigated. The mechanism of degradation and kinetics were also explored. The results indicated that iron copper had a greater degradation ability towards BCAN, and the degradation rate of iron copper (mass ratio of 10:1) was 1.5 times that of the zero-valent iron. The removal of BCAN increased obviously with the increase of Fe/Cu dosage. When the initial concentration was set at 20 microg x L(-1), after a reaction time of 150 min, removal of BCAN was improved from 51.1% to 89.5% with the increase of iron copper (mass ratio of 10:1) dosage from 5 g x L(-1) to 10 g x L(-1). The temperature also had great impact on BCAN removal and the removal increased with the increase of temperature. However, BCAN removal did not change a lot with the variation of the initial concentration of BCAN when it was at a low level. The BCAN degradation by iron copper catalytic-reduction followed the first-order kinetics model.
Improving bioelectricity generation and COD removal of sewage sludge in microbial desalination cell.
Ebrahimi, Atieh; Yousefi Kebria, Daryoush; Darzi, Ghasem Najafpour
2018-05-01
Improving wastewater treatment process and water desalination are two important solutions for increasing the available supply of fresh water. Microbial desalination cells (MDCs) with common electrolytes display relatively low organic matter removal and high cost. In this study, sewage sludge was used as the substrate in the Microbial desalination cell (MDC) under three different initial salt concentrations (5, 20 and 35 g.L -1 ) and the maximum salt removal rates of 50.6%, 64% and 69.6% were obtained under batch condition, respectively. The MDC also produced the maximum power density of 47.1 W m -3 and the averaged chemical oxygen demand (COD) removal of 58.2 ± 0.89% when the initial COD was 6610 ± 83 mg L -1 . Employing treated sludge as catholyte enhanced COD removal and power density to 87.3% and 54.4 W m -3 , respectively, with counterbalancing pH variation in treated effluent. These promising results showed, for the first time, that the excess sewage sludge obtained from biological wastewater treatment plants could be successfully used as anolyte and catholyte in MDC, achieving organic matter biodegradation along with salt removal and energy production. In addition, using treated sludge as catholyte will improve the performance of MDC and introduce a more effective method for both sludge treatment and desalination.
ERIC Educational Resources Information Center
Rhodes, Anne E.; Boyle, Michael H.; Bethell, Jennifer; Wekerle, Christine; Tonmyr, Lil; Goodman, Deborah; Leslie, Bruce; Lam, Kelvin; Manion, Ian
2013-01-01
Objectives: To identify factors associated with repeat emergency department (ED) presentations for suicide-related behaviors (SRB)--hereafter referred to as repetition--among children/youth to aid secondary prevention initiatives. To compare rates of repetition in children/youth with substantiated maltreatment requiring removal from their parental…
Martorell, María M; Rosales Soro, María Del M; Pajot, Hipólito F; de Figueroa, Lucía I C
2017-09-16
Trichosporon akiyoshidainum HP2023 is a basidiomycetous yeast isolated from Las Yungas rainforest (Tucumán, Argentina) and selected based on its outstanding textile-dye-decolorizing ability. In this work, the decolorization process was optimized using Reactive Black 5 as dye model. Lactose and urea were chosen as carbon and nitrogen sources through a one-at-time approach. Afterwards, factorial designs were employed for medium optimization, leading to the formulation of a simpler optimized medium which contains in g L -1 : lactose 10, yeast extract 1, urea 0.5, KH 2 PO 4 1 and MgSO 4 1. Temperature and agitation conditions were also optimized. The optimized medium and incubation conditions for dye removal were extrapolated to other dyes individually and a mixture of them. Dye removal process happened through both biosorption and biodegradation mechanisms, depending primarily on the dye structure. A positive relation between initial inoculum and dye removal rate and a negative relation between initial dye concentration and final dye removal percentages were found. Under optimized conditions, T. akiyoshidainum HP2023 was able to completely remove a mixture of dyes up to a concentration of 300 mg L -1 , a concentration much higher than those expected in real effluents.
Kabdaşli, Işik; Arslan, Tülin; Olmez-Hanci, Tuğba; Arslan-Alaton, Idil; Tünay, Olcay
2009-06-15
In the present study, the treatability of a metal plating wastewater containing complexed metals originating from the nickel and zinc plating process by electrocoagulation using stainless steel electrodes was experimentally investigated. The study focused on the effect of important operation parameters on electrocoagulation process performance in terms of organic complex former, nickel and zinc removals as well as sludge production and specific energy consumption. The results indicated that increasing the applied current density from 2.25 to 9.0 mA/cm(2) appreciably enhanced TOC removal efficiency from 20% to 66%, but a further increase in the applied current density to 56.25 mA/cm(2) did not accelerate TOC removal rates. Electrolyte concentration did not affect the process performance significantly and the highest TOC reduction (66%) accompanied with complete heavy metal removals were achieved at the original chloride content ( approximately 1500 mg Cl/L) of the wastewater sample. Nickel removal performance was adversely affected by the decrease of initial pH from its original value of 6. Optimum working conditions for electrocoagulation of metal plating effluent were established as follows: an applied current density of 9 mA/cm(2), the effluent's original electrolyte concentration and pH of the composite sample. TOC removal rates obtained for all electrocoagulation runs fitted pseudo-first-order kinetics very well (R(2)>92-99).
Catheter-associated bloodstream infections in pediatric hematology-oncology patients.
Celebi, Solmaz; Sezgin, Melike Evim; Cakır, Deniz; Baytan, Birol; Demirkaya, Metin; Sevinir, Betul; Bozdemir, Sefika Elmas; Gunes, Adalet Meral; Hacimustafaoglu, Mustafa
2013-04-01
Catheter-associated bloodstream infections (CABSIs) are common complications encountered with cancer treatment. The aims of this study were to analyze the factors associated with recurrent infection and catheter removal in pediatric hematology-oncology patients. All cases of CABSIs in patients attending the Department of Pediatric Hematology-Oncology between January 2008 and December 2010 were reviewed. A total of 44 episodes of CABSIs, including multiple episodes involving the same catheter, were identified in 31 children with cancer. The overall CABSIs rate was 7.4 infections per 1000 central venous catheter (CVC) days. The most frequent organism isolated was coagulase-negative Staphylococcus (CONS). The CVC was removed in nine (20.4%) episodes. We found that hypotension, persistent bacteremia, Candida infection, exit-side infection, neutropenia, and prolonged duration of neutropenia were the factors for catheter removal. There were 23 (52.2%) episodes of recurrence or reinfection. Mortality rate was found to be 9.6% in children with CABSIs. In this study, we found that CABSIs rate was 7.4 infections per 1000 catheter-days. CABSIs rates in our hematology-oncology patients are comparable to prior reports. Because CONS is the most common isolated microorganism in CABSIs, vancomycin can be considered part of the initial empirical regimen.
Luo, Le; He, Huijun; Yang, Chunping; Wen, Shan; Zeng, Guangming; Wu, Mengjie; Zhou, Zili; Lou, Wei
2016-09-01
Coelastrella sp. QY01, a microalgae species isolated from a local pond, was identified and used for the treatment of anaerobically and aerobically treated swine wastewater (AnATSW). Microalgal growth characteristics, nutrient removal and lipid accumulation of QY01 cultivated in the initial concentration of AnATSW ranged from 63 to 319mg NH3-N/L were examined. The specific growth rate of QY01 cultivated in cultures ranged from 0.269 to 0.325day(-1) with a biomass productivity from 42.77 to 57.46mgL(-1)day(-1). Removal rates for NH3-N, TP and inorganic carbon in AnATSW at the various nutrient concentrations ranged from 90% to 100%, from 90% to 100% and from 74% to 78%, respectively. The lipid content of QY01 ranged from 22.4% to 24.8%. The lipid productivity was positive correlation with the biomass productivity. 40% AnATSW was optimal for QY01 cultivation, in which nutrient removal and productivity of biomass and lipid were maximized. Copyright © 2016 Elsevier Ltd. All rights reserved.
Shemfe, Mobolaji; Gadkari, Siddharth; Yu, Eileen; Rasul, Shahid; Scott, Keith; Head, Ian M; Gu, Sai; Sadhukhan, Jhuma
2018-05-01
A novel framework, integrating dynamic simulation (DS), life cycle assessment (LCA) and techno-economic assessment (TEA) of a bioelectrochemical system (BES), has been developed to study for the first time wastewater treatment by removal of chemical oxygen demand (COD) by oxidation in anode and thereby harvesting electron and proton for carbon dioxide reduction reaction or reuse to produce products in cathode. Increases in initial COD and applied potential increase COD removal and production (in this case formic acid) rates. DS correlations are used in LCA and TEA for holistic performance analyses. The cost of production of HCOOH is €0.015-0.005 g -1 for its production rate of 0.094-0.26 kg yr -1 and a COD removal rate of 0.038-0.106 kg yr -1 . The life cycle (LC) benefits by avoiding fossil-based formic acid production (93%) and electricity for wastewater treatment (12%) outweigh LC costs of operation and assemblage of BES (-5%), giving a net 61MJkg -1 HCOOH saving. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Rivera-Rivera, Carlos J.; Montoya-Burgos, Juan I.
2016-01-01
Phylogenetic inference artifacts can occur when sequence evolution deviates from assumptions made by the models used to analyze them. The combination of strong model assumption violations and highly heterogeneous lineage evolutionary rates can become problematic in phylogenetic inference, and lead to the well-described long-branch attraction (LBA) artifact. Here, we define an objective criterion for assessing lineage evolutionary rate heterogeneity among predefined lineages: the result of a likelihood ratio test between a model in which the lineages evolve at the same rate (homogeneous model) and a model in which different lineage rates are allowed (heterogeneous model). We implement this criterion in the algorithm Locus Specific Sequence Subsampling (LS³), aimed at reducing the effects of LBA in multi-gene datasets. For each gene, LS³ sequentially removes the fastest-evolving taxon of the ingroup and tests for lineage rate homogeneity until all lineages have uniform evolutionary rates. The sequences excluded from the homogeneously evolving taxon subset are flagged as potentially problematic. The software implementation provides the user with the possibility to remove the flagged sequences for generating a new concatenated alignment. We tested LS³ with simulations and two real datasets containing LBA artifacts: a nucleotide dataset regarding the position of Glires within mammals and an amino-acid dataset concerning the position of nematodes within bilaterians. The initially incorrect phylogenies were corrected in all cases upon removing data flagged by LS³. PMID:26912812
ENHANCED CHEMICAL CLEANING: EFFECTIVENESS OF THE UV LAMP TO DECOMPOSE OXALATES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ketusky, E.; Huff, T.; Sudduth, C.
2010-01-19
Enhanced Chemical Cleaning is a new process scheduled to begin cleaning Savannah River Site High Level Waste Tanks in 2012. It is an improvement over the current chemical cleaning method, in that it minimizes downstream impacts on the High Level Waste System. It is based on a state of the art scale removal process used on the secondary side of nuclear power plants, with modifications to accommodate the unique constraints created by the tanks. Both Enhanced Chemical Cleaning and the scale removal process are founded on dissolving metal oxides/hydroxides using oxalic acid, with subsequent oxalate decomposition via hydroxylation using ozonemore » or peroxide, and UV light as a catalyst. A divergence Enhanced Chemical Cleaning has from nuclear power scale removal is the significantly increased solids concentration during oxalate decomposition. These solids can limit the ability of the UV light to create hydroxyl radicals, either by limiting the ability of the light to penetrate through the solution, or by increasing the fouling rate on the UV light. Both will decrease the overall catalytic effectiveness, thereby decreasing the concentration of formed hydroxyl radicals. The hydroxyl radicals are the driving force behind the oxalate decomposition. To understand the impact of increased solids, testing was performed using a medium pressure UV light inside an ozone supplied Oxalate Decomposition Reactor. Using a dissolved metal sludge simulant with an initial oxalate concentration greater than 12,000 ppm, and an initial pH of about 2.0, the spent acid solution was recirculated through the reactor, while the UV light was allowed to foul. For the first few hours, the oxalate decomposition rate was about 1,300 ppm/hour. After about 3 hours, enough time for the UV lamp to foul, the oxalate decomposition rate decreased to about 500 ppm/hour. The decomposition rate then remained roughly constant for the next 16 hours. Overall, testing showed that the oxalate destruction rate decreased by about 2.8. Results from very similartests with similar chemistry suggest that the impact should be about 10. Based on the limited reaction pathwayfor the creation of hydroxyl radicals with iron, ozone, and no UV, the discrepancy suggests that initially, at 'time zero' the UV light failed to perform up to expectations. It is therefore concluded that regardless of the fouling rate, either the increased solids concentration is impacting the initial penetrability (i.e. to many solids), or the light is not adequately sized/configured to have the appropriate flux.« less
High-rate sulphidogenic fluidised-bed treatment of metal-containing wastewater at high temperature.
Sahinkaya, E; Ozkaya, B; Kaksonen, A H; Puhakka, J A
2007-01-01
The applicability of fluidised-bed reactor (FBR) based sulphate reducing bioprocess was investigated for the treatment of iron containing (40-90 mg/L) acidic wastewater at 65 degrees C. The FBR was inoculated with sulphate-reducing bacteria (SRB) originally enriched from a hot mining environment. Ethanol or acetate was supplemented as carbon and electron source for the SRB. A rapid startup with 99.9, 46 and 29% ethanol, sulphate and acetate removals, in respective order, was observed even after 6 days. Iron was almost completely removed with a rate of 90 mg/L.d. The feed pH was decreased gradually from its initial value of 6 to around 3.7 during 100 days of operation. The wastewater pH of 4.3-4.4 was neutralised by the alkalinity produced in acetate oxidation and the average effluent pH was 7.8 +/- 0.8. Although ethanol removal was complete, acetate accumulated. Later the FBR was fed with acetate only. Although acetate was present in the reactor for 295 days, its oxidation rates did not improve, which may be due to low growth rate and poor attachment ability of acetate oxidising SRB. Hence, the oxidation of acetate is the rate limiting step in the sulphidogenic ethanol oxidation by the thermophilic SRB.
Solution and surface chemistry of the Se(IV)-Fe(0) reactions: Effect of initial solution pH.
Xia, Xuefen; Ling, Lan; Zhang, Wei-Xian
2017-02-01
Aspects of solution and solid-phase reactions between selenite (Se(IV)) and nanoscale zero-valent iron (nZVI) were investigated. Experimental results on the effects of initial solution pH, formation and evolution of nZVI corrosion products, and speciation of selenium in nZVI were presented. In general, the rate of Se(IV) removal decreases with increasing initial pH. The observed rate constants of Se(IV) removal decreased from 0.3530 to 0.0364 min -1 as pH increased from 4.0 to 10.0. Composition and morphology of nZVI corrosion products and selenium species were characterized using scanning electron microscopy (SEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). Results confirmed that Se(IV) was reduced to Se(0) and Se(-II) by nZVI. Lower solution pH favored further reduction of Se(0) to Se(-II). Amorphous FeOOH, magnetite/maghemite (Fe 3 O 4 /γ-Fe 2 O 3 ) and ferrous hydroxide (Fe(OH) 2 ) were identified as the main corrosion products. Under alkaline conditions, the corrosion products were mainly of Fe(OH) 2 along with small amounts of Fe 3 O 4 , while nZVI in acidic solutions was oxidized to mostly Fe 3 O 4 and amorphous FeOOH. Furthermore, these corrosion products acted as intermediates for electron transfer and reactive/sorptive sites for Se(IV) adsorption and reduction, thus played a crucial role in the removal of aqueous Se(IV). Copyright © 2016. Published by Elsevier Ltd.
Al-Gheethi, A A; Mohamed, R M; Jais, N M; Efaq, A N; Abd Halid, Abdullah; Wurochekke, A A; Amir-Hashim, M K
2017-10-01
The present study aims to investigate the influence of Staphylococcus aureus, Escherichia coli and Enterococcus faecalis in public market wastewater on the removal of nutrients in terms of ammonium (NH 4 - ) and orthophosphate (PO 4 3 ) using Scenedesmus sp. The removal rates of NH 4 - and orthophosphate PO 4 3- and batch kinetic coefficient of Scenedesmus sp. were investigated. The phycoremediation process was carried out at ambient temperature for 6 days. The results revealed that the pathogenic bacteria exhibited survival potential in the presence of microalgae but they were reduced by 3-4 log at the end of the treatment process. The specific removal rates of NH 4 - and PO 4 3- have a strong relationship with initial concentration in the public market wastewater (R 2 = 0.86 and 0.80, respectively). The kinetic coefficient of NH 4 - removal by Scenedesmus sp. was determined as k = 4.28 mg NH 4 - 1 log 10 cell mL -1 d -1 and k m = 52.01 mg L -1 (R 2 = 0.94) while the coefficient of PO 4 3- removal was noted as k = 1.09 mg NH 4 - 1 log 10 cell mL -1 d -1 and k m = 85.56 mg L -1 (R 2 = 0.92). It can be concluded that Scenedesmus sp. has high competition from indigenous bacteria in the public market wastewater to remove nutrients, with a higher coefficient of removal of NH 4 - than PO 4 3 .
Treatment of As(V) and As(III) by electrocoagulation using Al and Fe electrode.
Kuan, W H; Hu, C Y; Chiang, M C
2009-01-01
A batch electrocoagulation (EC) process with bipolar electrode and potentiodynamic polarization tests with monopolar systems were investigated as methods to explore the effects of electrode materials and initial solution pH on the As(V) and As(III) removal. The results displayed that the system with Al electrode has higher reaction rate during the initial period from 0 to 25 minutes than that of Fe electrode for alkaline condition. The pH increased with the EC time because the As(V) and As(III) removal by either co-precipitation or adsorption resulted in that the OH positions in Al-hydroxide or Fe-hydroxide were substituted by As(V) and As(III). The pH in Fe electrode system elevate higher than that in Al electrode because the As(V) removal substitutes more OH position in Fe-hydroxide than that in Al-hydroxide. EC system with Fe electrode can successfully remove the As(III) but system with Al electrode cannot because As(III) can strongly bind to the surface of Fe-hydroxide with forming inner-sphere species but weakly adsorb to the Al-hydroxide surface with forming outer-sphere species. The acidic solution can destroy the deposited hydroxide passive film then allow the metallic ions liberate into the solution, therefore, the acidic initial solution can enhance the As(V) and As(III) removal. The over potential calculation and potentiodynamic polarization tests reveal that the Fe electrode systems possess higher over potential and pitting potential than that of Al electrode system due to the fast hydrolysis of and the occurrence of Fe-hydroxide passive film.
Syed, Atiq U.; Bennett, James P.; Rachol, Cynthia M.
2005-01-01
Four dams on the Kalamazoo River between the cities of Plainwell and Allegan, Mich., are in varying states of disrepair. The Michigan Department of Environmental Quality (MDEQ) and U.S. Environmental Protection Agency (USEPA) are considering removing these dams to restore the river channels to pre-dam conditions. This study was initiated to identify sediment characteristics, monitor sediment transport, and predict sediment resuspension and deposition under varying hydraulic conditions. The mathematical model SEDMOD was used to simulate streamflow and sediment transport using three modeling scenarios: (1) sediment transport simulations for 730 days (Jan. 2001 to Dec. 2002), with existing dam structures, (2) sediment transport simulations based on flows from the 1947 flood at the Kalamazoo River with existing dam structures, and (3) sediment transport simulations based on flows from the 1947 flood at the Kalamazoo River with dams removed. Sediment transport simulations based on the 1947 flood hydrograph provide an estimate of sediment transport rates under maximum flow conditions. These scenarios can be used as an assessment of the sediment load that may erode from the study reach at this flow magnitude during a dam failure. The model was calibrated using suspended sediment as a calibration parameter and root mean squared error (RMSE) as an objective function. Analyses of the calibrated model show a slight bias in the model results at flows higher than 75 m3/s; this means that the model-simulated suspended-sediment transport rates are higher than the observed rates; however, the overall calibrated model results show close agreement between simulated and measured values of suspended sediment. Simulation results show that the Kalamazoo River sediment transport mechanism is in a dynamic equilibrium state. Model results during the 730-day simulations indicate significant sediment erosion from the study reach at flow rates higher than 55 m3/s. Similarly, significant sediment deposition occurs during low to average flows (monthly mean flows between 25.49 m3/s and 50.97 m3/s) after a high-flow event. If the flow continues to stay in the low to average range the system shifts towards equilibrium, resulting in a balancing effect between sediment deposition and erosion rates. The 1947 flood-flow simulations show approximately 30,000 m3 more instream sediments erosion for the first 21 days of the dams removed scenario than for the existing-dams scenario, with the same initial conditions for both scenarios. Application of a locally weighted regression smoothing (LOWESS) function to simulation results of the dams removed scenario indicates a steep downtrend with high sediment transport rates during the first 21 days. In comparison, the LOWESS curve for the existing-dams scenario shows a smooth transition of sediment transport rates in response to the change in streamflow. The high erosion rates during the dams-removed scenario are due to the absence of the dams; in contrast, the presence of dams in the existing-dams scenario helps reduce sediment erosion to some extent. The overall results of 60-day simulations for the 1947 flood show no significant difference in total volume of eroded sediment between the two scenarios, because the dams in the study reach have low heads and no control gates. It is important to note that the existing-dams and dams-removed scenarios simulations are run for only 60 days; therefore, the simulations take into account the changes in sediment erosion and deposition rates only during that time period. Over an extended period, more erosion of instream sediments would be expected to occur if the dams are not properly removed than under the existing conditions. On the basis of model simulations, removal of dams would further lower the head in all the channels. This lowering of head could produce higher flow velocities in the study reach, which ultimately would result in accelerated erosion rates.
Muthukkumaran, A; Aravamudan, K
2017-12-15
Adsorption, a popular technique for removing azo dyes from aqueous streams, is influenced by several factors such as pH, initial dye concentration, temperature and adsorbent dosage. Any strategy that seeks to identify optimal conditions involving these factors, should take into account both kinetic and equilibrium aspects since they influence rate and extent of removal by adsorption. Hence rigorous kinetics and accurate equilibrium models are required. In this work, the experimental investigations pertaining to adsorption of acid orange 10 dye (AO10) on activated carbon were carried out using Central Composite Design (CCD) strategy. The significant factors that affected adsorption were identified to be solution temperature, solution pH, adsorbent dosage and initial solution concentration. Thermodynamic analysis showed the endothermic nature of the dye adsorption process. The kinetics of adsorption has been rigorously modeled using the Homogeneous Surface Diffusion Model (HSDM) after incorporating the non-linear Freundlich adsorption isotherm. Optimization was performed for kinetic parameters (color removal time and surface diffusion coefficient) as well as the equilibrium affected response viz. percentage removal. Finally, the optimum conditions predicted were experimentally validated. Copyright © 2017 Elsevier Ltd. All rights reserved.
Bai, Jing; Zhao, Yong-Sheng; Sun, Chao; Qin, Chuan-Yu; Yu, Ling
2014-10-01
A two-dimension simulated sand box was set up to investigate the influencing factors, such as the initial groundwater level, aeration rate and the initial groundwater rate, that affect groundwater circulation well (GCW) by determining the intensity of groundwater circulation which was characterized by the variation of groundwater level before and after aeration. The optimal operating parameters were used to remediate nitrobenzene contaminated aquifer. The results demonstrated that: GCW could be well operated under the conditions of 45 cm groundwater level, 0.7 m3 · h(-1) aeration rate. The effects of groundwater velocity less than 1.0 m · d(-1) could be ignored. The lateral mobility rate of nitrobenzene was faster than that of longitudinal. The average concentration of nitrobenzene was 246.97 mg · L(-1) on day 50 of leakage. During the remediation of circulation well, an efficient organics remediation region was gradually formed around the circulation well. The organics in this region was removed preferentially, and the concentration decreased continuously. Besides the efficient remediation region, there was a transient region, where the concentration of organics was influenced by the combined effects of adsorption/desorption and migration potential of organics. During the whole remediation process, the concentration of nitrobenzene went through three stages described as rapid removal, slow removal. After 14h aeration, the nitrobenzene average concentration was reduced to 71.19 mg L(-1). The residual nitrobenzene was distributed in regions far away from GCW. Therefore, nitrobenzene contaminated aquifer could be well remediated by GCW, and there were optimal operation conditions and appropriate remediation time which guaranteed the best remediation effect.
Combined ultrasound and Fenton (US-Fenton) process for the treatment of ammunition wastewater.
Li, Yangang; Hsieh, Wen-Pin; Mahmudov, Rovshan; Wei, Xiaomei; Huang, C P
2013-01-15
A wastewater collected from a regional ammunition process site was treated with combined US-Fenton process. Factors such as pH, temperature, reaction time, US energy intensity, initial TOC concentration, and the molar ratio of iron to hydrogen peroxide that might affect the treatment efficiency were investigated. The removal of TOC, COD, and color increased with decreasing pH and increasing temperature and US intensity. Color was removed rapidly reaching 85% in 10 min; whereas TOC and COD were removed slowly, only about 20% for both in 10 min and approaching 65 and 92% removal in 120 min, respectively. The optimal molar ratio of Fe(II) to H(2)O(2) for TOC and COD removal was 500. The results showed that the change in the average carbon oxidation number (ACON) was parallel to that of the removal efficiency of TOC, COD, and color. The toxicity of treated wastewater was reduced as assessed by the respiration rate of Escherichia coli. Copyright © 2013 Elsevier B.V. All rights reserved.
Treatment of oily wastewater of a gas refinery by electrocoagulation using aluminum electrodes.
Saeedi, Mohesn; Khalvati-Fahlyani, Amin
2011-03-01
Oily wastewaters are the most important discharges of gas refineries from an environmental point-of-view. In the present study, treatment of gas refinery oily wastewater by electrocoagulation using aluminum electrodes was investigated. The effects of electrode distance, initial pH, sodium sulfate (Na2SO4) as a supporting electrolyte, polyaluminum chloride dosage as a coagulant aid, and current density on the efficiency of chemical oxygen demand (COD) removal were examined. The results revealed that the COD removal rate increases by applying more current density and polyaluminum chloride and, to a lesser extent, Na2SO4 dosage. The results also showed that 97% COD can be removed at optimum operational conditions. Specific electrical energy consumption could be reduced from 19.48 kWh (kg COD removal)(-1) to 11.057 kWh (kg COD removal)(-1) using Na2SO4 as a supporting electrolyte. Gas chromatographic analysis of raw and treated wastewater also revealed that most normal hydrocarbons (nearly 99%) were removed during the electrocoagulation process.
Decomposition of 2,4,6-trinitrotoluene (TNT) by gamma irradiation.
Lee, Byungjin; Lee, Myunjoo
2005-12-01
The purpose of this study was to evaluate the potential of gamma irradiation to decompose 2,4,6-trinitrotoluene (TNT) in an aqueous solution; the concentration range of the TNT solution was 0.11-0.44 mmol/L. The decomposition rate of TNT by gamma irradiation was pseudo-first-order kinetic over the applied initial concentrations. The dose constant was strongly dependent on the initial concentration of TNT. Increasing the concentration of dissolved oxygen in the solution was more effective on the decomposition of TNT as well as its mineralization. The required irradiation dose to remove 90% of initial TNT (0.44 mmol/L) was 58, 41, 32, 28, and 25 kGy at the dissolved oxygen concentration of 0.025, 0.149, 0.3, 0.538, and 0.822 mmol/L, respectively. However, TOC still remained as 30% of the initial TOC (3.19 mmol/L) when 200 kGy irradiation dose was applied to the TNT solution (0.44 mmol/L) containing dissolved oxygen of 0.822 mmol/L. The removal of the TNT was more efficient at a pH below 3 and at a pH above 11 than at neutral pH (pH 5-9). The required irradiation dose to remove over 99% of the initial TNT (0.44 mmol/L) was 39, 76, and 10 kGy at pH 2, 7, and 13, respectively. The dose constant was increased 1.6-fold and over 15.6-fold at pH 2 and 13, respectively, compared to that at pH 7. When an irradiation dose of 200 kGy was applied, the removal efficiencies of the TOC (initial concentration 3.19 mmol/L) were 91, 46, and 53% at pH 2, 7, and 13, respectively. Ammonia and nitrate were detected as the main nitrogen byproducts of TNT, and glyoxalic acid and oxalic acid were detected as organic byproducts.
NASA Astrophysics Data System (ADS)
Tehrani, Mahnaz Saghanejhad; Zare-Dorabei, Rouholah
2016-05-01
MIL-68(Al) as a metal-organic framework (MOF) was synthesized and characterized by different techniques such as SEM, BET, FTIR, and XRD analysis. This material was then applied for simulations removal of malachite green (MG) and methylene blue (MB) dyes from aqueous solutions using second order derivative spectrophotometric method (SODS) which was applied to resolve the overlap between the spectra of these dyes. The dependency of dyes removal efficiency in binary solutions was examined and optimized toward various parameters including initial dye concentration, pH of the solution, adsorbent dosage and ultrasonic contact time using central composite design (CCD) under response surface methodology (RSM) approach. The optimized experimental conditions were set as pH 7.78, contact time 5 min, initial MB concentration 22 mg L- 1, initial MG concentration 12 mg L- 1 and adsorbent dosage 0.0055 g. The equilibrium data was fitted to isotherm models such as Langmuir, Freundlich and Tempkin and the results revealed the suitability of the Langmuir model. The maximum adsorption capacity of 666.67 and 153.85 mg g- 1 was obtained for MB and MG removal respectively. Kinetics data fitting to pseudo-first order, pseudo-second order and Elovich models confirmed the applicability of pseudo-second order kinetic model for description of the mechanism and adsorption rate. Dye-loaded MIL-68(Al) can be easily regenerated using methanol and applied for three frequent sorption/desorption cycles with high performance. The impact of ionic strength on removal percentage of both dyes in binary mixture was studied by using NaCl and KCl soluble salts at different concentrations. According to our findings, only small dosage of the proposed MOF is considerably capable to remove large amounts of dyes at room temperature and in very short time that is a big advantage of MIL-68(Al) as a promising adsorbent for adsorptive removal processes.
Zhang, Qinghua; Zhang, Yanyan; Li, Daping
2017-04-01
The performance of a microbial fuel cell (MFC) in terms of degradation of chloramphenicol (CAP) was investigated. Approximately 84% of 50mg/L CAP was degraded within 12h in the MFC. A significant interaction of pH, temperature, and initial CAP concentration was found on removal of CAP, and a maximum degradation rate of 96.53% could theoretically be achieved at 31.48°C, a pH of 7.12, and an initial CAP concentration of 106.37mg/L. Moreover, CAP was further degraded through a ring-cleavage pathway. The antibacterial activity of CAP towards Escherichia coli ATCC 25922 and Shewanella oneidensis MR-1 was largely eliminated by MFC treatment. High-throughput sequencing analysis indicated that Azonexus, Comamonas, Nitrososphaera, Chryseobacterium, Azoarcus, Rhodococcus, and Dysgonomonas were the predominant genera in the MFC anode biofilm. In conclusion, the MFC shows potential for the treatment of antibiotic residue-containing wastewater due to its high rates of CAP removal and energy recovery. Copyright © 2017 Elsevier Ltd. All rights reserved.
Gas Removal in the Ursa Minor Galaxy: Linking Hydrodynamics and Chemical Evolution Models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caproni, Anderson; Lanfranchi, Gustavo Amaral; Baio, Gabriel Henrique Campos
2017-04-01
We present results from a non-cosmological, three-dimensional hydrodynamical simulation of the gas in the dwarf spheroidal galaxy Ursa Minor. Assuming an initial baryonic-to-dark-matter ratio derived from the cosmic microwave background radiation, we evolved the galactic gas distribution over 3 Gyr, taking into account the effects of the types Ia and II supernovae. For the first time, we used in our simulation the instantaneous supernovae rates derived from a chemical evolution model applied to spectroscopic observational data of Ursa Minor. We show that the amount of gas that is lost in this process is variable with time and radius, being themore » highest rates observed during the initial 600 Myr in our simulation. Our results indicate that types Ia and II supernovae must be essential drivers of the gas loss in Ursa Minor galaxy (and probably in other similar dwarf galaxies), but it is ultimately the combination of galactic winds powered by these supernovae and environmental effects (e.g., ram-pressure stripping) that results in the complete removal of the gas content.« less
Optimization of Malachite Green Removal from Water by TiO₂ Nanoparticles under UV Irradiation.
Ma, Yongmei; Ni, Maofei; Li, Siyue
2018-06-13
TiO₂ nanoparticles with surface porosity were prepared by a simple and efficient method and presented for the removal of malachite green (MG), a representative organic pollutant, from aqueous solution. Photocatalytic degradation experiments were systematically conducted to investigate the influence of TiO₂ dosage, pH value, and initial concentrations of MG. The kinetics of the reaction were monitored via UV spectroscopy and the kinetic process can be well predicted by the pseudo first-order model. The rate constants of the reaction kinetics were found to decrease as the initial MG concentration increased; increased via elevated pH value at a certain amount of TiO₂ dosage. The maximum efficiency of photocatalytic degradation was obtained when the TiO₂ dosage, pH value and initial concentrations of MG were 0.6 g/L, 8 and 10 −5 mol/L (M), respectively. Results from this study provide a novel optimization and an efficient strategy for water pollutant treatment.
Patulin reduction in apple juice by inactivated Alicyclobacillus spp.
Yuan, Y; Wang, X; Hatab, S; Wang, Z; Wang, Y; Luo, Y; Yue, T
2014-12-01
This study aimed to investigate the reduction of patulin (PAT) in apple juice by 12 inactivated Alicyclobacillus strains. The reduction rate of PAT by each strain was determined by high-performance liquid chromatography (HPLC). The results indicated that the removal of PAT was strain specific. Alicyclobacillus acidoterrestris 92 and A. acidoterrestris 96 were the most effective ones among the 12 tested strains in the removal of PAT. Therefore, these two strains were selected to study the effects of incubation time, initial PAT concentration and bacteria powder amount on PAT removal abilities of Alicyclobacillus. The highest PAT reduction rates of 88·8 and 81·6% were achieved after 24-h incubation with initial PAT concentration of 100 μg l(-1) and bacteria powder amount of 40 g l(-1) , respectively. Moreover, it was found that the treatment by these 12 inactivated Alicyclobacillus strains had no negative effect on the quality parameters of apple juice. Similar assays were performed in supermarket apple juice, where inactivated Alicyclobacillus cells could efficiently reduce PAT content. Taken together, these data suggest the possible application of this strategy as a means to detoxify PAT-contaminated juices. Inactivated Alicyclobacillus cells can efficiently reduce patulin concentration in apple juice. It provides a theoretical foundation for recycling of Alicyclobacillus cells from spoiled apple juice to reduce the source of pollution and the cost of juice industry. This is the first report on the use of Alicyclobacillus to remove patulin from apple juice. © 2014 The Society for Applied Microbiology.
Kim, Seungjin; Bae, Wookeun; Hwang, Jungmin; Park, Jaewoo
2010-01-01
The degradation rates of toluene and trichloroethylene (TCE) by Pseudomonas putida and Bacillus spp. that were encapsulated in polyethylene glycol (PEG) polymers were evaluated in comparison with the results of exposure to suspended cultures. PEG monomers were polymerized together with TCE-degrading microorganisms, such that the cells were encapsulated in and protected by the matrices of the PEG polymers. TCE concentrations were varied from 0.1 to 1.5 mg/L. In the suspended cultures of P. putida, the TCE removal rate decreased as the initial TCE concentration increased, revealing TCE toxicity or a limitation of reducing power, or both. When the cells were encapsulated, an initial lag period of about 10-20 h was observed for toluene degradation. Once acclimated, the encapsulated P. putida cultures were more tolerant to TCE at an experimental range of 0.6-1.0 mg/L and gave higher transfer efficiencies (mass TCE transformed/mass toluene utilized). When the TCE concentration was low (e.g., 0.1 mg/L) the removal of TCE per unit mass of cells (specific removal) was significantly lower, probably due to a diffusion limitation into the PEG pellet. Encapsulated Bacillus spp. were able to degrade TCE cometabolically. The encapsulated Bacillus spp. gave significantly higher values than did P. putida in the specific removal and the transfer efficiency, particularly at relatively high TCE concentration of approximately 1.0±0.5 mg/L. The transfer efficiency by encapsulated Bacillus spp. in this study was 0.27 mgTCE/mgToluene, which was one to two orders of magnitude greater than the reported values.
Effect of oxidized leachate on degradation of lignin by sulfate-reducing bacteria.
Kim, Jong-Ho; Kim, Moonil; Bae, Wooken
2009-08-01
Municipal solid waste materials (MSWs) in landfills need a long period of stabilization because lignin compounds in MSWs and leachate are not readily biodegraded, but inhibit methanogenic metabolism. Recirculation of leachate into the landfill offers the potential advantage of increasing the rate of decomposition of organic matter. However, the degradation of lignin by leachate recirculation alone is quite difficult. Several recent studies have demonstrated that sulfate-reducing bacteria (SRB) were able to degrade lignin compounds. In this study, batch tests were conducted to investigate the impacts of SRB enrichment on lignin decomposition rates as well as the decomposition of other biodegradable organics. Further, the effects of nitrite and nitrate on lignin degradation rates were also studied. A 16S rRNA assay showed that the SRB used herein, which were obtained by enriching solid waste collected from a closed MSW landfill, were Thaurea sp. and Desulfovibrio sp. Lignin was found to be biodegraded by the SRB and the rate of lignin removal per unit of waste volatile suspended solid was 2.9 mg lignin g(-1) VSS day(- 1). It was found that the initial degradation rate increased under higher initial lignin concentrations. However, the degradation rate during days 6-19 became slower than that during the initial 9 days because lignin consisted of complexly bonded aromatic compounds that were not readily biodegradable. Adding other organics such as lactate seemed to improve the rate and amount of lignin degradation, probably due to the increase in SRB associated with consumption of the additional organics. The lignin removal percentage decreased with increases in oxidized nitrogen (nitrite or nitrate) concentrations, indicating that oxidized nitrogen could inhibit SRB activity. Conclusively, the study verified the existence of SRB in the landfill and showed that the SRB could be activated for the degradation of lignin by the recirculation of the leachate, which is consistent with other studies showing that leachate recirculation could shorten the stabilization period of the landfill.
Throop, Heather L; Archer, Steven R
2007-09-01
Encroachment of woody plants into grasslands, and subsequent brush management, are among the most prominent changes to occur in arid and semiarid systems over the past century. Despite the resulting widespread changes in landcover, substantial uncertainty about the biogeochemical impacts of woody proliferation and brush management exists. We explored the role of shrub encroachment and brush management on leaf litter decomposition in a semidesert grassland where velvet mesquite (Prosopis velutina) abundance has increased over the past 100 years. This change in physiognomy may affect decomposition directly, through altered litter quality or quantity, and indirectly through altered canopy structure. To assess the direct and indirect impacts of shrubs on decomposition, we quantified changes in mass, nitrogen, and carbon in litterbags deployed under mesquite canopies and in intercanopy zones. Litterbags contained foliage from mesquite and Lehmann lovegrass (Eragrostis lehmanniana), a widespread, nonnative grass in southern Arizona. To explore short- and long-term influences of brush management on the initial stages of decomposition, litterbags were deployed at sites where mesquite canopies were removed three weeks, 45 years, or 70 years prior to study initiation. Mesquite litter decomposed more rapidly than lovegrass, but negative indirect influences of mesquite canopies counteracted positive direct effects. Decomposition was positively correlated with soil infiltration into litterbags, which varied with microsite placement, and was lowest under canopies. Low under-canopy decomposition was ostensibly due to decreased soil movement associated with high under-canopy herbaceous biomass. Decomposition rates where canopies were removed three weeks prior to study initiation were comparable to those beneath intact canopies, suggesting that decomposition was driven by mesquite legacy effects on herbaceous cover-soil movement linkages. Decomposition rates where shrubs were removed 45 and 70 years prior to study initiation were comparable to intercanopy rates, suggesting that legacy effects persist less than 45 years. Accurate decomposition modeling has proved challenging in arid and semiarid systems but is critical to understanding biogeochemical responses to woody encroachment and brush management. Predicting brush-management effects on decomposition will require information on shrub-grass interactions and herbaceous biomass influences on soil movement at decadal timescales. Inclusion of microsite factors controlling soil accumulation on litter would improve the predictive capability of decomposition models.
Yao, Kangning; Chi, Yong; Wang, Fei; Yan, Jianhua; Ni, Mingjiang; Cen, Kefa
2016-01-01
A commonly used aeration device at present has the disadvantages of low mass transfer rate because the generated bubbles are several millimeters in diameter which are much bigger than microbubbles. Therefore, the effect of a microbubble on gas-liquid mass transfer and wastewater treatment process was investigated. To evaluate the effect of each bubble type, the volumetric mass transfer coefficients for microbubbles and conventional bubbles were determined. The volumetric mass transfer coefficient was 0.02905 s(-1) and 0.02191 s(-1) at a gas flow rate of 0.67 L min(-1) in tap water for microbubbles and conventional bubbles, respectively. The degradation rate of simulated municipal wastewater was also investigated, using aerobic activated sludge and ozone. Compared with the conventional bubble generator, the chemical oxygen demand (COD) removal rate was 2.04, 5.9, 3.26 times higher than those of the conventional bubble contactor at the same initial COD concentration of COD 200 mg L(-1), 400 mg L(-1), and 600 mg L(-1), while aerobic activated sludge was used. For the ozonation process, the rate of COD removal using microbubble generator was 2.38, 2.51, 2.89 times of those of the conventional bubble generator. Based on the results, the effect of initial COD concentration on the specific COD degradation rate were discussed in different systems. Thus, the results revealed that microbubbles could enhance mass transfer in wastewater treatment and be an effective method to improve the degradation of wastewater.
Gao, Ji-xian; Wang, Tie-feng; Wang, Jin-fu
2010-05-01
The influence of SO2 dynamic adsorption behaviors using ZL50 activated carbon for flue gas desulphurization and denitrification under different SO2 volume fraction was investigated experimentally, and the kinetic analysis was conducted by kinetic models. With the increase of SO2 volume fraction in flue gas, the SO2 removal ratio and the activity ratio of ZL50 activated carbon decreased, respectively, and SO2 adsorption rate and capacity increased correspondingly. The calculated results indicate that Bangham model has the best prediction effect, the chemisorption processes of SO2 was significantly affected by catalytic oxidative reaction. The adsorption rate constant of Lagergren's pseudo first order model increased with the increase of inlet SO, volume fraction, which indicated that catalytic oxidative reaction of SO2 adsorbed by ZL50 activated carbon may be the rate controlling step in earlier adsorption stage. The Lagergren's and Bangham's initial adsorption rate were deduced and defined, respectively. The Ho's and Elovich's initial adsorption rate were also deduced in this paper. The Bangham's initial adsorption rate values were defined in good agreement with those of experiments. The defined Bangham's adsorptive reaction kinetic model can describe the SO2 dynamic adsorption rate well. The studied results indicated that the SO2 partial order of initial reaction rate was one or adjacent to one, while the O2 and water vapor partial order of initial reaction rate were constants ranging from 0.15-0.20 and 0.45-0.50, respectively.
Work, Timothy T.; Klimaszewski, Jan; Thiffault, Evelyne; Bourdon, Caroline; Paré, David; Bousquet, Yves; Venier, Lisa; Titus, Brian
2013-01-01
Abstract Increased interest in biomass harvesting for bioenergetic applications has raised questions regarding the potential ecological consequences on forest biodiversity. Here we evaluate the initial changes in the abundance, species richness and community composition of rove (Staphylinidae) and ground beetles (Carabidae), immediately following 1) stem-only harvesting (SOH), in which logging debris (i.e., tree tops and branches) are retained on site, and 2) whole-tree harvesting (WTH), in which stems, tops and branches are removed in mature balsam fir stands in Quebec, Canada. Beetles were collected throughout the summer of 2011, one year following harvesting, using pitfall traps. Overall catch rates were greater in uncut forest (Control) than either stem-only or whole-tree harvested sites. Catch rates in WTH were greater than SOH sites. Uncut stands were characterized primarily by five species: Atheta capsularis, Atheta klagesi, Atheta strigosula, Tachinus fumipennis/frigidus complex (Staphylinidae) and to a lesser extent to Pterostichus punctatissimus (Carabidae). Increased catch rates in WTH sites, where post-harvest biomass was less, were attributable to increased catches of rove beetles Pseudopsis subulata, Quedius labradorensis and to a lesser extent Gabrius brevipennis. We were able to characterize differences in beetle assemblages between harvested and non-harvested plots as well as differences between whole tree (WTH) and stem only (SOH) harvested sites where logging residues had been removed or left following harvest. However, the overall assemblage response was largely a recapitulation of the responses of several abundant species. PMID:23653498
Work, Timothy T; Klimaszewski, Jan; Thiffault, Evelyne; Bourdon, Caroline; Paré, David; Bousquet, Yves; Venier, Lisa; Titus, Brian
2013-01-01
Increased interest in biomass harvesting for bioenergetic applications has raised questions regarding the potential ecological consequences on forest biodiversity. Here we evaluate the initial changes in the abundance, species richness and community composition of rove (Staphylinidae) and ground beetles (Carabidae), immediately following 1) stem-only harvesting (SOH), in which logging debris (i.e., tree tops and branches) are retained on site, and 2) whole-tree harvesting (WTH), in which stems, tops and branches are removed in mature balsam fir stands in Quebec, Canada. Beetles were collected throughout the summer of 2011, one year following harvesting, using pitfall traps. Overall catch rates were greater in uncut forest (Control) than either stem-only or whole-tree harvested sites. Catch rates in WTH were greater than SOH sites. Uncut stands were characterized primarily by five species: Atheta capsularis, Atheta klagesi, Atheta strigosula, Tachinus fumipennis/frigidus complex (Staphylinidae) and to a lesser extent to Pterostichus punctatissimus(Carabidae). Increased catch rates in WTH sites, where post-harvest biomass was less, were attributable to increased catches of rove beetles Pseudopsis subulata, Quedius labradorensis and to a lesser extent Gabrius brevipennis. We were able to characterize differences in beetle assemblages between harvested and non-harvested plots as well as differences between whole tree (WTH) and stem only (SOH) harvested sites where logging residues had been removed or left following harvest. However, the overall assemblage response was largely a recapitulation of the responses of several abundant species.
Li, Lei; Gong, Li; Wang, Yi-Xuan; Liu, Qi; Zhang, Jie; Mu, Yang; Yu, Han-Qing
2016-07-01
The removal performance and mechanisms of halogenated emerging contaminants from water by palladium decorated nitrogen-doped graphene (Pd/NG) were investigated in this study. For comparison, three catalysts of Pd/NG, palladium decorated graphene (Pd/G) and commercial Pd/C were initially explored to degrade tetrabromobisphenol A (TBBPA). After that, the influence of various environmental parameters on TBBPA removal by the Pd/NG catalyst was evaluated. Moreover, both Langmuir-Hinshelwood model and density functional theory (DFT) were adopted to theoretically elucidate the adsorption and the activation of TBBPA on the catalyst. The results show that the apparent rate constant of TBBPA dehalogenation was increased by 26.7% and 39.0% in the presence of the Pd/NG catalyst compared to the Pd/G and Pd/C ones. Higher temperature, catalyst dosage and alkaline conditions resulted in the enhancement of TBBPA dehalogenation by the Pd/NG catalyst, while humic acid in the solution had a negatively effect on the transformation of TBBPA. The corresponding rate constant value exhibited a 2.1- and 1.8-fold increase with the rise of temperature from 298 to 328 K and initial pH from 6.5 to 9.0, respectively. On the contrary, the rate constant was decreased by 78.9% in the presence of 15 mg L(-1) humic acid. Theoretical analysis revealed that both adsorption and activation processes of TBBPA on the Pd/NG catalyst were enhanced through the N doping into graphene framework. Copyright © 2016 Elsevier Ltd. All rights reserved.
Guo, Xiaoyan; Cai, Yaping; Wei, Zhongbo; Hou, Haifeng; Yang, Xi; Wang, Zunyao
2013-01-01
Interior microelectrolysis (IM) as a pretreatment process was effective to treat Reactive Black 5 (RB5) in this study. The removal rates of chemical oxygen demand (COD), total organic carbon (TOC) and color were 46.05, 39.99 and 98.77%, respectively, when this process was conducted under the following optimal conditions: the volumetric ratio between iron scraps and active carbon (AC) (V(Fe)/V(C)) 1.0, pH 2.0, aeration dosage 0.6 L/min, and reaction time 100 min. Contaminants could be further removed by ozonation. After subsequent ozonation for 200 min, the solution could be completely decolorized, and the COD and TOC removal rates were up to 77.78 and 66.51%, respectively. In addition, acute toxicity tests with Daphnia magna showed that pretreatment by IM generated effluents that were more toxic when compared with the initial wastewater, and the toxicity was reduced after subsequent ozonation.
Li, Yongchao; Jin, Zhaohui; Li, Tielong; Li, Shujing
2011-01-01
Silica fume supported-Fe(0) nanoparticles (SF-Fe(0)) were prepared using commercial silica fume as a support. The feasibility of using this SF-Fe(0) for reductive immobilization of Cr(VI) was investigated through batch tests. Compared with unsupported Fe(0), SF-Fe(0) was significantly more active in Cr(VI) removal especially in 84 wt% silica fume loading. Silica fume had also been found to inhibit the formation of Fe(III)/Cr(III) precipitation on Fe nanoparticles' surface, which was increasing the deactivation resistance of iron. Cr(VI) was removed through physical adsorption of Cr(VI) onto the SF-Fe(0) surface and subsequent reduction of Cr(VI) to Cr(III). The rate of reduction of Cr(VI) could be expressed by pseudo first-order reaction kinetics. The rate constant increased with the increase in iron loading but decreased with the increase in initial Cr(VI) concentration. Furthermore, column tests showed that the SF-Fe(0) could be readily transported in model soil.
Nakai, Satoshi; Okuda, Tetsuji; Nishijima, Wataru; Okada, Mitsumasa
2015-10-01
Ozonation is believed to improve the biodegradability of organic compounds. In the present study, degradation of nonylphenol ethoxylates (NPEOs) was monitored in hybrid treatment systems consisting of ozonation and microbial degradation processes. We found that ozonation of NPEOs decreased, rather than increased, the biodegradability under certain conditions. The timing of ozonation was a definitive factor in determining whether ozonation increased or decreased the biodegradation rates of NPEOs. Initial ozonation of NPEOs prior to biodegradation reduced the rate of dissolved organic carbon (DOC) removal during the subsequent 14 d of biodegradation, whereas intermediate ozonation at the 9th day of biodegradation improved subsequent DOC removal during 14 d of NPEO biodegradation. Furthermore, reduction of DOC removal was also observed, when initial ozonation prior to biodegradation was subjected to cetyl alcohol ethoxylates. The production of less biodegradable intermediates, such as mono- and dicarboxylated polyethylene glycols (MCPEGs and DCPEGs), was responsible for the negative effect of ozonation on biodegradability of NPEOs. DCPEGs and MCPEGs were produced by biodegradation of polyethylene glycols (PEGs) that were ozonolysis products of the NPEOs, and the biodegradability of DCPEGs and MCPEGs was less than that of the precursor PEGs. The results indicate that, if the target chemicals contain ethoxy chains, production of PEGs may be one of the important factors when ozonation is considered. Copyright © 2015 Elsevier Ltd. All rights reserved.
Efficient removal of endosulfan from aqueous solution by UV-C/peroxides: a comparative study.
Shah, Noor S; He, Xuexiang; Khan, Hasan M; Khan, Javed Ali; O'Shea, Kevin E; Boccelli, Dominic L; Dionysiou, Dionysios D
2013-12-15
This study explored the efficiency of UV-C-based advanced oxidation processes (AOPs), i.e., UV/S2O8(2-), UV/HSO5(-), and UV/H2O2 for the degradation of endosulfan, an organochlorine insecticide and an emerging water pollutant. A significant removal, 91%, 86%, and 64%, of endosulfan, at an initial concentration of 2.45 μM and UV fluence of 480 mJ/cm(2), was achieved by UV/S2O8(2-), UV/HSO5(-), and UV/H2O2 processes, respectively, at a [peroxide]0/[endosulfan]0 molar ratio of 20. The efficiency of these processes was, however, inhibited in the presence of radical scavengers, such as alcohols (e.g., tertiary butyl alcohol and isopropyl alcohol) and natural organic matter (NOM). The inhibition was also influenced by common inorganic anions in the order of nitrite > bicarbonate > chloride > nitrate ≈ sulfate. The observed pseudo-first-order rate constant decreased while the degradation rate increased with increasing initial concentration of the target contaminant. The degradation mechanism of endosulfan by the AOPs was evaluated revealing the main by-product as endosulfan ether. Results of this study suggest that UV-C-based AOPs are potential methods for the removal of pesticides, such as endosulfan and its by-products, from contaminated water. Copyright © 2013 Elsevier B.V. All rights reserved.
Evaluating the Potential Efficacy of Invasive Lionfish (Pterois volitans) Removals
Barbour, Andrew B.; Allen, Michael S.; Frazer, Thomas K.; Sherman, Krista D.
2011-01-01
The lionfish, Pterois volitans (Linnaeus) and Pterois miles (Bennett), invasion of the Western Atlantic Ocean, Caribbean Sea and Gulf of Mexico has the potential to alter aquatic communities and represents a legitimate ecological concern. Several local removal programs have been initiated to control this invasion, but it is not known whether removal efforts can substantially reduce lionfish numbers to ameliorate these concerns. We used an age-structured population model to evaluate the potential efficacy of lionfish removal programs and identified critical data gaps for future studies. We used high and low estimates for uncertain parameters including: length at 50% vulnerability to harvest (Lvul), instantaneous natural mortality (M), and the Goodyear compensation ratio (CR). The model predicted an annual exploitation rate between 35 and 65% would be required to cause recruitment overfishing on lionfish populations for our baseline parameter estimates for M and CR (0.5 and 15). Lionfish quickly recovered from high removal rates, reaching 90% of unfished biomass six years after a 50-year simulated removal program. Quantifying lionfish natural mortality and the size-selective vulnerability to harvest are the most important knowledge gaps for future research. We suggest complete eradication of lionfish through fishing is unlikely, and substantial reduction of adult abundance will require a long-term commitment and may be feasible only in small, localized areas where annual exploitation can be intense over multiple consecutive years. PMID:21572951
NASA Astrophysics Data System (ADS)
Rediske, Nicole M.
The objective of this research was to characterize natural carbon fibers from coconut husks, both bare and impregnated with metallic nanoparticles, in removing cadmium from aqueous media. The adsorbent load, kinetics, isotherm parameters, removal efficiencies, desorption capacity and possible contaminant removal mechanisms were evaluated. It was found that the fibers treated with metallic nanoparticles performed better than the bare fibers in removing cadmium from water. The ideal conditions were found to be neutral pH with low initial cadmium concentrations. Through the kinetic analyses, the adsorption process was first thought to be pseudo first order with two separate adsorption mechanisms apparent. Upon further analysis, it was seen that the first mechanism does not follow the pseudo first order kinetics model. An increase in calcium and magnesium concentrations was observed as the cadmium concentrations decreases. This increase corresponds with first mechanism. This suggests the cadmium removal in the first mechanism is due to ion exchange. The second mechanism's rate constant was consistently lower than the first mechanisms rate constant by an order of magnitude. This led to the hypothesis that the second mechanism is controlled by van de Waals forces, specifically ion-induced dipole interactions, and physical adsorption. It was also found that the cadmium does not effectively desorb from the wasted fibers in DI water. Keywords: Adsorption; kinetics; pseudo first order; cadmium; metallic nanoparticles; natural fibers; removal efficiencies; ion exchange.
Tsui, L.; Krapac, I.G.; Roy, W.R.
2007-01-01
Nitrate is a major agricultural pollutant found in drainage waters. Immature yard-waste compost was selected as a filter media to study its feasibility for removing nitrate from drainage water. Different operation parameters were tested to examine the denitrification efficiency, including the amounts of compost packed in columns, the flow rate, and the compost storage periods. The experimental results suggested that hydraulic retention time was the major factor to determine the extent of nitrate removal, although the amount of compost packed could also contribute to the nitrate removal efficiency. The effluent nitrate concentration increased as the flow rate decreased, and the compost column reduced nitrate concentrations from 20 mg/L to less than 5 mg/L within 1.5 h. The solution pH increased at the onset of experiment because of denitrification, but stabilized at a pH of about 7.8, suggesting that the compost had a buffering capacity to maintain a suitable pH for denitrification. Storing compost under air-dried conditions may diminish the extent nitrate removed initially, but the effects were not apparent after longer applications. It appeared that immature yard-waste compost may be a suitable material to remove nitrate from tile drainage water because of its relatively large organic carbon content, high microbial activity, and buffering capacity. ?? 2006 Elsevier B.V. All rights reserved.
Evaluating the potential efficacy of invasive lionfish (Pterois volitans) removals.
Barbour, Andrew B; Allen, Micheal S; Allen, Michael S; Frazer, Thomas K; Sherman, Krista D
2011-05-10
The lionfish, Pterois volitans (Linnaeus) and Pterois miles (Bennett), invasion of the Western Atlantic Ocean, Caribbean Sea and Gulf of Mexico has the potential to alter aquatic communities and represents a legitimate ecological concern. Several local removal programs have been initiated to control this invasion, but it is not known whether removal efforts can substantially reduce lionfish numbers to ameliorate these concerns. We used an age-structured population model to evaluate the potential efficacy of lionfish removal programs and identified critical data gaps for future studies. We used high and low estimates for uncertain parameters including: length at 50% vulnerability to harvest (L(vul)), instantaneous natural mortality (M), and the Goodyear compensation ratio (CR). The model predicted an annual exploitation rate between 35 and 65% would be required to cause recruitment overfishing on lionfish populations for our baseline parameter estimates for M and CR (0.5 and 15). Lionfish quickly recovered from high removal rates, reaching 90% of unfished biomass six years after a 50-year simulated removal program. Quantifying lionfish natural mortality and the size-selective vulnerability to harvest are the most important knowledge gaps for future research. We suggest complete eradication of lionfish through fishing is unlikely, and substantial reduction of adult abundance will require a long-term commitment and may be feasible only in small, localized areas where annual exploitation can be intense over multiple consecutive years.
1980-09-01
1969 Submitted in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE IN MECHANICAL ENGINEERING from the NAVAL POSTGRADUATE... Science and Engineering 3 ABSTRACT A continuation of experiments initiated by Commander Calvin G. Miller, USN, on the effect of flow rate, flow geometry and...Salvage Department INaval Coastal Systems Center Panama City, Florida 32401 6. Commander, Naval Sea Systems Command 2 Supervisor of Diving (Code GOC
Leopold, Luna Bergere; Thomas, William L.
1956-01-01
When the vegetal cover is removed from a land surface, the rate of removal of the soil material, at least initially, increases rapidly. So well known is this principle that it hardly needs restatement.If attention is focused on any individual drainage basin in its natural state, large or small, and inquiry is made as to the rate of denudation, a quantitative answer is not easily obtained. The possible error in any computation of rate of sediment production from any given drainage basin is considerable. Significant variations are found in sediment yields from closely adjacent watersheds which appear to be generally similar. To make a quantitative evaluation of the change in the rate of denudation when the natural vegetation is disturbed is, therefore, even more difficult. Considering the fact that "soil conservation" has been promoted to the status of a science, our lack of ability to answer what is apparently so simple a question may seem surprising. Let us look at some of the reasons.
Sudden spreading of infections in an epidemic model with a finite seed fraction
NASA Astrophysics Data System (ADS)
Hasegawa, Takehisa; Nemoto, Koji
2018-03-01
We study a simple case of the susceptible-weakened-infected-removed model in regular random graphs in a situation where an epidemic starts from a finite fraction of initially infected nodes (seeds). Previous studies have shown that, assuming a single seed, this model exhibits a kind of discontinuous transition at a certain value of infection rate. Performing Monte Carlo simulations and evaluating approximate master equations, we find that the present model has two critical infection rates for the case with a finite seed fraction. At the first critical rate the system shows a percolation transition of clusters composed of removed nodes, and at the second critical rate, which is larger than the first one, a giant cluster suddenly grows and the order parameter jumps even though it has been already rising. Numerical evaluation of the master equations shows that such sudden epidemic spreading does occur if the degree of the underlying network is large and the seed fraction is small.
NASA Astrophysics Data System (ADS)
Mondal, Naba Kumar; Roy, Arunabha
2018-06-01
Contamination of underground water with fluoride (F) is a tremendous health hazard. Excessive F (> 1.5 mg/L) in drinking water can cause both dental and skeletal fluorosis. A fixed-bed column experiments were carried out with the operating variables such as different initial F concentrations, bed depths, pH and flow rates. Results revealed that the breakthrough time and exhaustion time decrease with increasing flow rate, decreasing bed depth and increasing influent fluoride concentration. The optimized conditions are: 10 mg/L initial fluoride concentration; flow rate 3.4 mL/min, bed depth 3.5 and pH 5. The bed depth service time model and the Thomas model were applied to the experimental results. Both the models were in good agreement with the experimental data for all the process parameters studied except flow rate, indicating that the models were appropriate for removal of F by natural banana peel dust in fix-bed design. Moreover, column adsorption was reversible and the regeneration was accomplished by pumping of 0.1 M NaOH through the loaded banana peel dust column. On the other hand, field water sample analysis data revealed that 86.5% fluoride can be removed under such optimized conditions. From the experimental results, it may be inferred that natural banana peel dust is an effective adsorbent for defluoridation of water.
Waewsak, Chaiwat; Nopharatana, Annop; Chaiprasert, Pawinee
2010-01-01
Based on the developed neural-fuzzy control system for anaerobic hybrid reactor (AHR) in wastewater treatment and biogas production, the neural network with backpropagation algorithm for prediction of the variables pH, alkalinity (Alk) and total volatile acids (TVA) at present day time t was used as input data for the fuzzy logic to calculate the influent feed flow rate that was applied to control and monitor the process response at different operations in the initial, overload influent feeding and the recovery phases. In all three phases, this neural-fuzzy control system showed great potential to control AHR in high stability and performance and quick response. Although in the overloading operation phase II with two fold calculating influent flow rate together with a two fold organic loading rate (OLR), this control system had rapid response and was sensitive to the intended overload. When the influent feeding rate was followed by the calculation of control system in the initial operation phase I and the recovery operation phase III, it was found that the neural-fuzzy control system application was capable of controlling the AHR in a good manner with the pH close to 7, TVA/Alk < 0.4 and COD removal > 80% with biogas and methane yields at 0.45 and 0.30 m3/kg COD removed.
Endoscopic papillary large balloon dilation for the removal of bile duct stones.
Kim, Jin Hong; Yang, Min Jae; Hwang, Jae Chul; Yoo, Byung Moo
2013-12-14
Endoscopic papillary large balloon dilation (EPLBD) with endoscopic sphincterotomy (EST) has been widely used as the alternative to EST along with endoscopic mechanical lithotripsy (EML) for the removal of large or difficult bile duct stones. Furthermore, EPLBD without EST was recently introduced as its simplified alternative technique. Thus, we systematically searched PubMed, Medline, the Cochrane Library and EMBASE, and analyzed all gathered data of EPLBD with and without EST, respectively, by using a single standardized definition, reviewing relevant literatures, published between 2003 and June 2013, where it was performed with large-diameter balloons (12-20 mm). The outcomes, including the initial success rate, the rate of needs for EML, and the overall success rate, and adverse events were assessed in each and compared between both of two procedures: "EPLBD with EST" and "EPLBD without EST". A total of 2511 procedures from 30 published articles were included in EPLBD with EST, while a total of 413 procedures from 3 published articles were included in EPLBD without EST. In the results of outcomes, the overall success rate was 96.5% in EPLBD with EST and 97.2% in EPLBD without EST, showing no significant difference between both of them. The initial success rate (84.0% vs 76.2%, P < 0.001) and the success rate of EPLBD without EML (83.2% vs 76.7%, P = 0.001) was significantly higher, while the rate of use of EML was significantly lower (14.1% vs 21.6%, P < 0.001), in EPLBD with EST. The rate of overall adverse events, pancreatitis, bleeding, perforation, other adverse events, surgery for adverse events, and fatal adverse events were 8.3%, 2.4%, 3.6%, 0.6%, 1.7%, 0.2% and 0.2% in EPLBD with EST and 7.0%, 3.9%, 1.9%, 0.5%, 0.7%, 0% and 0% in EPLBD without EST, respectively, showing no significant difference between both of them. In conclusion, recent accumulated results of EPLBD with or even without EST suggest that it is a safe and effective procedure for the removal of large or difficult bile duct stones without any additional risk of severe adverse events, when performed under appropriate guidelines.
He, Junyong; Li, Yulian; Cai, Xingguo; Chen, Kai; Zheng, Hejing; Wang, Chengming; Zhang, Kaisheng; Lin, Dongyue; Kong, Lingtao; Liu, Jinhuai
2017-05-01
A biocompatible and uniquely defined hydroxyapatite (HAP) adsorption membrane with a sandwich structure was developed for the removal of organic micropollutants for the first time. Both the adsorption and membrane technique were used for the removal of organic micropollutants. The hydrophilicity and hydrophobicity of the HAP adsorbent and membrane were tunable by controlling the surface structure of HAP. The adsorption of organic micropollutants on the HAP adsorbent was studied in batch experiments. The adsorption process was fit with the Freundlich model, while the adsorption kinetics followed the pseudo-second-order model. The HAP membrane could remove organic micropollutants effectively by dynamic adsorption in both aqueous and ethanol solutions. The removal efficiencies of organic micropollutants depended on the solution composition, membrane thickness and hydrophilicity, flow rate, and the initial concentration of organic micropollutants. The adsorption capacities of the HAP membrane with a sandwich structure (membrane thickness was 0.3 mm) were 6700, 6510, 6310, 5960, 5490, 5230, 4980 and 4360 L m -2 for 1-naphthyl amine, 2-naphthol, bisphenol S, propranolol hydrochloride, metolachlor, ethinyl oestradiol, 2,4-dichlorophenol and bisphenol A, respectively, when the initial concentration was 3.0 mg L -1 . The biocompatible HAP adsorption membrane can be easily regenerated by methanol and was thus demonstrated to be a novel concept for the removal of organic micropollutants from both aqueous and organic solutions. Copyright © 2017 Elsevier Ltd. All rights reserved.
Liu, Huijuan; Ru, Jia; Qu, Jiuhui; Dai, Ruihua; Wang, Zijian; Hu, Chun
2009-06-01
A new biomimetic absorbent, cellulose acetate (CA) embedded with triolein (CA-triolein), was prepared and applied for the removal of persistent organic pollutants (POPs) from micro-polluted aqueous solution. The comparison of CA-triolein, CA and granular activated carbon (GAC) for dieldrin removal was investigated. Results showed that CA-triolein absorbent gave a lowest residual concentration after 24 h although GAC had high removal rate in the first 4 h adsorption. Then the removal efficiency of mixed POPs (e.g. aldrin, dieldrin, endrin and heptachlor epoxide), absorption isotherm, absorbent regeneration and initial column experiments of CA-triolein were studied in detail. The linear absorption isotherm and the independent absorption in binary isotherm indicated that the selected POPs are mainly absorbed onto CA-triolein absorbent by a partition mechanism. The absorption constant, K, was closely related to the hydrophobic property of the compound. Thermodynamic calculations showed that the absorption was spontaneous, with a high affinity and the absorption was an endothermic reaction. Rinsing with hexane the CA-triolein absorbent can be regenerated after absorption of POPs. No significant decrease in the dieldrin removal efficiency was observed even when the absorption-regeneration process was repeated for five times. The results of initial column experiments showed that the CA-triolein absorbent did not reach the breakthrough point at a breakthrough empty-bed volume (BV) of 3200 when the influent concentration was 1-1.5 microg/L and the empty-bed contact time (EBCT) was 20 min.
Enhanced adsorption of arsenic through the oxidative treatment of reduced aquifer solids.
Huling, Jenna R; Huling, Scott G; Ludwig, Ralph
2017-10-15
Arsenic (As) contamination in drinking water is an epidemic in many areas of the world, especially Eastern Asian countries. Developing affordable and efficient procedures to remove arsenic from drinking water is critical to protect human health. In this study, the oxidation of aquifer solids through the use of sodium permanganate (NaMnO 4 ), hydrogen peroxide (H 2 O 2 ), and exposure to air, enhanced the adsorption of arsenic to the aquifer material resulting in treatment of the water. NaMnO 4 was more effective than H 2 O 2 . NaMnO 4 was tested at different loading rates (0.5, 1.5, 2.4, 3.4, and 4.9 g NaMnO 4 /kg aquifer material), and after 30 days contact time, arsenic removal ([As +3 ] INITIAL = 610 μg/L) was 77%, 88%, 93%, 95%, 97%, respectively, relative to un-oxidized aquifer material. Arsenic removal increased with increasing contact time (30, 60, 90 days) suggesting removal was not reversible under the conditions of these experiments. Oxidative treatment by exposing the aquifer solids to air for 68 days resulted in >99% removal of Arsenic ([As +3 ] INITIAL = 550 μg/L). Less arsenic removal (38.2%) was measured in the un-oxidized aquifer material. In-situ oxidation of aquifer materials using NaMnO 4 , or ex-situ oxidation of aquifer materials through exposure to air could be effective in the removal of arsenic in ground water and a potential treatment method to protect human health. Published by Elsevier Ltd.
Particle-bound metal transport after removal of a small dam in ...
The Pawtuxet River in Rhode Island, USA, has a long history of industrial activity and pollutant discharges. Metal contamination of the river sediments is well documented and historically exceeded toxicity thresholds for a variety of organisms. The Pawtuxet River dam, a low-head dam at the mouth of the river, was removed in August 2011. The removal of the dam was part of an effort to restore the riverine ecosystem after centuries of anthropogenic impact. Sediment traps were deployed below the dam to assess changes in metal concentrations and fluxes (Ag, Cd, Cr, Cu, Ni, Pb, and Zn) from the river system into Pawtuxet Cove. Sediment traps were deployed for an average duration of 24 days each, and deployments continued for 15 months after the dam was removed. Metal concentrations in the trapped suspended particulate matter dropped after dam removal (e.g., 460 to 276 mg/kg for Zn) and remained below preremoval levels for most of the study. However, particle-bound metal fluxes increased immediately after dam removal (e.g., 1206 to 4248 g/day for Zn). Changes in flux rates during the study period indicated that river volumetric flow rates acted as the primary mechanism controlling the flux of metals into Pawtuxet Cove and ultimately upper Narragansett Bay. Even though suspended particulate matter metal concentrations initially dropped after removal of the dam, no discernable effect on the concentration or flux of the study metals exiting the river could be associa
Role of UV photolysis in accelerating the biodegradation of 2,4,6-TCP.
Wang, Wenbing; Kirumba, George; Zhang, Yongming; Wu, Yanqing; Rittmann, Bruce E
2015-09-18
2,4,6-TCP, a kind of chlorinated aromatic and aliphatic compound, is difficult to be biodegraded by ordinary microorganisms. UV photolysis and biodegradation of 2,4,6-TCP by Bacillus amyloliquefaciens intimate coupling is a potential means to accelerate its biotransformation. The initial steps of 2,4,6-TCP biodegradation involve mono-oxygenation reactions that have molecular oxygen and an intracellular electron carrier as cosubstrates. It was demonstrated that B. amyloliquefaciens has the 2,4,6-TCP monooxygenase gene tcpA which could encode 2,4,6-TCP monooxygenase (TCP-MO). TCP-MO would catalytically decompose 2,4,6-TCP into 2,6-DCHQ. We employed an internal loop photolytic biofilm reactor for 2,4,6-TCP degradation. Sequentially coupled photolysis and biodegradation experimental results suggested that 2,4,6-TCP removal rate in P + B (TCP(UV) + phenol) protocol was higher by 77 and 103 % when compared to B (TCP + phenol) and B (TCP-only) protocols respectively. The corresponding loss rate coefficient (k) values were 0.069, 0.039, 0.034 mg/L·min -1 respectively. This is because UV photolysis converted 2,4,6-TCP into its intermediates: 2,4-dichlorophenol (2,4-DCP), 4-monochlorophenol (4-MCP), phenol, 2,6-dichloro-p-hydroquinone (2,6-DCHQ), with all displaying less inhibition to bacterial action. In addition, phenol was the crucial UV-photolysis product from 2,4,6-TCP, its catabolic oxidation generating internal electron carriers that may accelerate the initial steps of 2,4,6-TCP biodegradation. Intimately coupled photolysis and biodegradation experimental results suggested that 2,4,6-TCP removal rate in P&B (TCP + phenol) protocol was higher by 166 and 681 % when compared to P&B (TCP-only) and P + B protocols respectively. The corresponding loss rate coefficient (k) values were 0.539, 0.203, 0.069 mg/L·min -1 respectively. It provided sufficient evidence to demonstrate that intimately coupled photolysis and biodegradation accelerated 2,4,6-TCP removal much faster than sequentially coupled photolysis and biodegradation. In addition, oxidation of phenol was the mechanism by which intimately coupled photolysis and biodegradation accelerated rapid 2,4,6-TCP removal producing electron equivalents that stimulated the initial mono-oxygenation reactions for 2,4,6-TCP biodegradation. It is important to note that 2,6-DCHQ (produced from UV-photolysis products or initial mono-oxygenation reactions) would be catalytically decomposed into 6-chlorohydroxyquinol (6-CHQ). Based on this, a tentative reaction mechanism for the photo-biodegradation 2,4,6-TCP was proposed.
Imel, Zac E.; Sheng, Elisa; Baldwin, Scott A.; Atkins, David C.
2016-01-01
Therapists can impact the likelihood a given patient will benefit from psychotherapy. However, therapists are rarely held accountable for their patients' outcomes. As a result, low performing providers likely continue to practice alongside providers with high response rates. In the current study, we conducted a Monte Carlo simulation to illustrate a thought experiment—what happens to patient outcomes if therapists with the worst outcomes were removed from practice? We drew initial samples of 50 therapists from three simulated populations of 1,000 therapists with a mean patient response rate of 50% and different effect sizes for therapist variability in outcomes. We simulated 30 patient outcomes for each therapist, with outcome defined as response to treatment versus no response. We removed therapists with response rates in the bottom 5% and replaced them with a random sample of therapists from the population. Over 10 years, the difference in responses between the lowest and highest performing therapists was substantial (between 697 and 997 additional responses to treatment). After repeatedly removing the lowest performing providers 40 times (simulating a 10 year time span), response rates increased substantially. The cumulative number of patient responses (i.e., summing the total number of responses across 10 years) increased by 4266, 6404, and 9307 when therapists accounted for 5%, 10%, or 20% of the patient outcome variance, respectively. These findings indicate that performance-based retention of therapists could improve the quality of psychotherapy in health systems by improving the average response rate and decreasing the probability that a patient will be treated by a therapist who has little chance of helping. PMID:26301424
Huang, Fei; Pan, Luqing; Lv, Na; Tang, Xianming
2017-11-01
The development of an intensive aquaculture industry has been accompanied by increasing environmental impacts, especially nitrogen pollution. In this study, a novel halophilic bacterium capable of heterotrophic nitrification and aerobic denitrification was isolated from mariculture water and identified as Bacillus litoralis N31. The efficiency of ammonium, nitrite and nitrate removal by N31 were 86.3%, 89.3% and 89.4%, respectively, after a 48-h cultivation in sole N-source medium with initial nitrogen approximately 20 mg/L. However, ammonium was removed preferentially, and no obvious nitrite accumulated during the simultaneous nitrification and denitrification process in mixed N-source media. The existence of hao, napA and nirS genes further proved the heterotrophic nitrification-aerobic denitrification capability of N31. The optimal conditions for ammonium removal were 30°C, initial pH 7.5-8.5, C/N ratio 5-20 and salinity 30-40‰, and the nitrification rate of N31 increased with increasing initial [Formula: see text] from 10 to 250 mg/L. Biosecurity assessment with shrimp indicated that strain N31 could be applied in the marine aquaculture industry safely for culture water remediation and effluent treatment. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
Xia, Lan-Yan; Gu, Ding-Hong; Tan, Jing; Dong, Wen-Bo; Hou, Hui-Qi
2008-04-01
The photolysis of simulating low concentration of hydrogen sulfide malodorous gas was studied under UV irradiation emitted by self-made microwave discharge electrodeless lamps (i.e. microwave UV electrodeless mercury lamp (185/253.7 nm) and iodine lamp (178.3/180.1/183/184.4/187.6/206.2 nm)). Experiments results showed that the removal efficiency (eta H2S) of hydrogen sulfide was decreased with increasing initial H2S concentration and increased slightly with gas residence time; H2S removal efficiency was decreased dramatically with enlarged pipe diameter. Under the experimental conditions with pipe diameter of 36 mm, gas flow rate of 0.42 standard l s(-1), eta H2S was 52% with initial H2S concentration of 19.5 mg m(-3) by microwave mercury lamp, the absolute removal amount (ARA) was 4.30 microg s(-1), and energy yield (EY) was 77.3 mg kW h(-1); eta H2S was 56% with initial H2S concentration of 18.9 mg m(-3) by microwave iodine lamp, the ARA was 4.48 microg s(-1), and the EY was 80.5mg kW h(-1). The main photolysis product was confirmed to be SO4(2-) with IC.
Parasite Removal, but Not Herbivory, Deters Future Parasite Attachment on Tomato
Tjiurutue, Muvari Connie; Palmer-Young, Evan C.; Adler, Lynn S.
2016-01-01
Plants face many antagonistic interactions that occur sequentially. Often, plants employ defense strategies in response to the initial damage that are highly specific and can affect interactions with subsequent antagonists. In addition to herbivores and pathogens, plants face attacks by parasitic plants, but we know little about how prior herbivory compared to prior parasite attachment affects subsequent host interactions. If host plants can respond adaptively to these different damage types, we predict that prior parasitism would have a greater deterrent effect on subsequent parasites than would prior herbivory. To test the effects of prior parasitism and prior herbivory on subsequent parasitic dodder (Cuscuta spp.) preference, we conducted two separate greenhouse studies with tomato hosts (Solanum lycopersicum). In the first experiment, we tested the effects of previous dodder attachment on subsequent dodder preference on tomato hosts using three treatments: control plants that had no previous dodder attachment; dodder-removed plants that had an initial dodder seedling attached, removed and left in the same pot to simulate parasite death; and dodder-continuous plants with an initial dodder seedling that remained attached. In the second experiment, we tested the effects of previous caterpillar damage (Spodoptera exigua) and mechanical damage on future dodder attachment on tomato hosts. Dodder attached most slowly to tomato hosts that had dodder plants previously attached and then removed, compared to control plants or plants with continuous dodder attachment. In contrast, herbivory did not affect subsequent dodder attachment rate. These results indicate that dodder preference depended on the identity and the outcome of the initial attack, suggesting that early-season interactions have the potential for profound impacts on subsequent community dynamics. PMID:27529694
Bioretention Design to Improve Nitrogen Removal | Science ...
Bioretention has been shown to effectively remove a variety of stormwater stressors, including oil/grease, heavy metals, phosphorus, and ammonium. However, reported nitrate and total nitrogen removal performance is highly variable. The media typically used in bioretention installation is coarse-grained with low organic matter content, which facilitates high infiltration rates but fails to provide the anaerobic conditions and carbon availability necessary to promote nitrate removal by denitrification. EPA's research at the Urban Watershed Research Facility investigates the effects of media carbon amendments, introduced internal storage zones, plant type, and media volume on nitrogen removal. Initial bench-scale tests informed media and carbon amendment choices. A locally-available, sandy media with low organic matter content was added to eight experimental, pilot-scale rain gardens above a shallow pea gravel drainage layer. The media was separated from the pea gravel with a nonwoven geotextile. Double-shredded hardwood wood chips were chosen as a carbon amendment and added as a 20-cm layer 10 cm above the geotextile in four of the eight pilot-scale rain gardens; the other four did not receive the mulch layer. Four rain gardens were constructed with an elevated outlet pipe to create an internal storage zone; the other four drain freely. Pilot-scale rain gardens were constructed in tanks of two sizes to test the effects of media volume. After initial hydrologic
Degradation mechanism of cyanide in water using a UV-LED/H2O2/Cu2+ system.
Kim, Tae-Kyoung; Kim, Taeyeon; Jo, Areum; Park, Suhyun; Choi, Kyungho; Zoh, Kyung-Duk
2018-06-01
In this study, we developed a UV-LED/H 2 O 2 /Cu 2+ system to remove cyanide, which is typically present in metal electroplating wastewater. The results showed the synergistic effects of UV-LED, H 2 O 2 , and Cu 2+ ions on cyanide removal in comparison with UV-LED photolysis, H 2 O 2 oxidation, UV-LED/H 2 O 2 , and H 2 O 2 /Cu 2+ systems. Cyanide was removed completely in 30 min in the UV-LED/H 2 O 2 /Cu 2+ system, and its loss followed pseudo-first order kinetics. Statistically, both H 2 O 2 and Cu 2+ ions showed positive effects on cyanide removal, but Cu 2+ ions exhibited a greater effect. The highest cyanide removal rate constant (k = 0.179 min -1 ) was achieved at pH 11, but the lowest was achieved at pH 12.5 (k = 0.064 min -1 ) due to the hydrolysis of H 2 O 2 (pK a of H 2 O 2 = 11.75). The presence of dissolved organic matter (DOM) inhibited cyanide removal, and the removal rate constant exhibited a negative linear correlation with DOM (R 2 = 0.987). The removal rate of cyanide was enhanced by the addition of Zn 2+ ions (from 0.179 to 0.457 min -1 ), while the co-existence of Ni 2+ or Cr +6 ion with Cu 2+ ion reduced cyanide removal. The formation of OH radicals in the UV-LED/H 2 O 2 /Cu 2+ system was verified using an aminophenyl fluorescence (APF) probe. Cyanate ions and ammonia were detected as the byproducts of cyanide decomposition. Finally, an acute toxicity reduction of 64.6% was achieved in the system within 1 h, despite a high initial cyanide concentration (100 mg/L). In terms of removal efficiency and toxicity reduction, the UV-LED/H 2 O 2 /Cu 2+ system may be an alternative method of cyanide removal from wastewaters. Copyright © 2018 Elsevier Ltd. All rights reserved.
Fenton Oxidation Kinetics and Intermediates of Nonylphenol Ethoxylates
Cui, Kai; Yi, Hao; Zhou, Zi-jian; Zhuo, Qiong-fang; Bing, Yong-xin; Guo, Qing-wei; Xu, Zhen-cheng
2014-01-01
Abstract Removal of nonylphenol ethoxylates (NPEOs) in aqueous solution by Fenton oxidation process was studied in a laboratory-scale batch reactor. Operating parameters, including initial pH temperature, hydrogen peroxide, and ferrous ion dosage, were thoroughly investigated. Maximum NPEOs reduction of 84% was achieved within 6 min, under an initial pH of 3.0, 25°C, an H2O2 dosage of 9.74×10−3 M, and a molar ratio of [H2O2]/[Fe2+] of 3. A modified pseudo-first-order kinetic model was found to well represent experimental results. Correlations of reaction rate constants and operational parameters were established based on experimental data. Results indicated that the Fenton oxidation rate and removal efficiency were more dependent on the dosage of H2O2 than Fe2+, and the apparent activation energy (ΔE) was 17.5 kJ/mol. High-performance liquid chromatography and gas chromatograph mass spectrometer analytical results indicated degradation of NPEOs obtained within the first 2 min stepwise occurred by ethoxyl (EO) unit shortening. Long-chain NPEOs mixture demonstrated a higher degradation rate than shorter-chain ones. Nonylphenol (NP), short-chain NPEOs, and NP carboxyethoxylates were identified as the primary intermediates, which were mostly further degraded. PMID:24868141
Rivera-Rivera, Carlos J; Montoya-Burgos, Juan I
2016-06-01
Phylogenetic inference artifacts can occur when sequence evolution deviates from assumptions made by the models used to analyze them. The combination of strong model assumption violations and highly heterogeneous lineage evolutionary rates can become problematic in phylogenetic inference, and lead to the well-described long-branch attraction (LBA) artifact. Here, we define an objective criterion for assessing lineage evolutionary rate heterogeneity among predefined lineages: the result of a likelihood ratio test between a model in which the lineages evolve at the same rate (homogeneous model) and a model in which different lineage rates are allowed (heterogeneous model). We implement this criterion in the algorithm Locus Specific Sequence Subsampling (LS³), aimed at reducing the effects of LBA in multi-gene datasets. For each gene, LS³ sequentially removes the fastest-evolving taxon of the ingroup and tests for lineage rate homogeneity until all lineages have uniform evolutionary rates. The sequences excluded from the homogeneously evolving taxon subset are flagged as potentially problematic. The software implementation provides the user with the possibility to remove the flagged sequences for generating a new concatenated alignment. We tested LS³ with simulations and two real datasets containing LBA artifacts: a nucleotide dataset regarding the position of Glires within mammals and an amino-acid dataset concerning the position of nematodes within bilaterians. The initially incorrect phylogenies were corrected in all cases upon removing data flagged by LS³. © The Author 2016. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.
Mechanisms of mercury removal by O 3 and OH in the atmosphere
NASA Astrophysics Data System (ADS)
Calvert, Jack G.; Lindberg, Steve E.
The mechanisms of the reactions of gaseous Hg atoms with O 3 and OH radical are evaluated from current kinetic and enthalpy data. The reaction, O 3+Hg→HgO+O 2, is considered to be an unlikely pathway for atmospheric conditions. Considerations given here suggest that the reaction may occur with initial formation of a metastable HgO 3 molecule that in laboratory experiments is the source of the HgO product observed to accumulate on the walls of the reactor (HgO 3→HgO(s)+O 2). Laboratory studies of the gas phase reaction, Hg+OH→HgOH (2), have been reported using relative rate measurements initiated by photodissociation of an organic nitrite in mixtures of Hg vapor with NO, air and various reference hydrocarbons. Computer simulations of this reaction system suggest that the use of reactive reference gases (e.g., cyclohexane) leads to the generation of significant ozone in these NO x-RH-air mixtures, and the resulting O 3-Hg reaction can result in an over-estimate of the rate of reaction (2). Also the apparent rate coefficients for reaction (2) are highly dependent on the assumed rate coefficients of its competitive reactions of dissociation in HgOH→Hg+OH (3), and association of HgOH molecule with other free radicals present in the system: HgOH+ X→ XHgOH (4); X=OH, HO 2, RO, RO 2, NO, NO 2. Reaction (4) competes successfully with HgOH decomposition for the laboratory conditions employed, and the kinetic measurements relate to the rate determining reaction, Hg+OH→HgOH in this case. However, the use of these laboratory measurements of k2 to determine the extent of Hg removal by OH in the troposphere will greatly over-estimate the importance of Hg removal by this reaction.
Characterization of chemical interactions during chemical mechanical polishing (CMP) of copper
NASA Astrophysics Data System (ADS)
Lee, Seung-Mahn
2003-10-01
Chemical mechanical polishing (CMP) has received much attention as an unique technique to provide a wafer level planarization in semiconductor manufacturing. However, despite the extensive use of CMP, it still remains one of the least understood areas in semiconductor processing. The lack of the fundamental understanding is a significant barrier to further advancements in CMP technology. One critical aspect of metal CMP is the formation of a thin surface layer on the metal surface. The formation and removal of this layer controls all the aspects of the CMP process, including removal rate, surface finish, etc. In this dissertation, we focus on the characterization of the formation and removal of the thin surface layer on the copper surface. The formation dynamics was investigated using static and dynamic electrochemical techniques, including potentiodynamic scans and chronoamperometry. The results were validated using XPS measurements. The mechanical properties of the surface layer were investigated using nanoindentation measurements. The electrochemical investigation showed that the thickness of the surface layer is controlled by the chemicals such as an oxidizer (hydrogen peroxide), a corrosion inhibitor (benzotriazole), a complexing agent (citric acid), and their concentrations. The dynamic electrochemical measurements indicated that the initial layer formation kinetics is unaffected by the corrosion inhibitors. The passivation due to the corrosion inhibitor becomes important only on large time scales (>200 millisecond). The porosity and the density of the chemically modified surface layer can be affected by additives of other chemicals such as citric acid. An optimum density of the surface layer is required for high polishing rate while at the same time maintaining a high degree of surface finish. Nanoindentation measurements indicated that the mechanical properties of the surface layer are strongly dependent on the chemical additives in the slurry. The CMP removal rates were found to be in good agreement with the initial reaction kinetics as well as the mechanical properties of the chemically modified surface layer. In addition, the material removal model based on the micro- and nano-scale interactions, which were measured experimentally, has been developed.
Complete and simultaneous removal of ammonium and m-cresol in a nitrifying sequencing batch reactor.
Zepeda, Alejandro; Ben-Youssef, Chérif; Rincón, Susana; Cuervo-López, Flor; Gómez, Jorge
2013-06-01
The kinetic behavior, oxidizing ability and tolerance to m-cresol of a nitrifying sludge exposed to different initial concentrations of m-cresol (0-150 mg C L(-1)) were evaluated in a sequencing batch reactor fed with 50 mg NH4 (+)-N L(-1) and operated during 4 months. Complete removal of ammonium and m-cresol was achieved independently of the initial concentration of aromatic compound in all the assays. Up to 25 mg m-cresol-C L(-1) (C/N ratio of 0.5), the nitrifying yield (Y-NO3 (-)) was 0.86 ± 0.05, indicating that the nitrate was the main product of the process; no biomass growth was detected. From 50 to 150 mg m-cresol-C L(-1) (1.0 ≤ C/N ≤ 3.0), simultaneous microbial growth and partial ammonium-to-nitrate conversion were obtained, reaching a maximum microbial total protein concentration of 0.763 g L(-1) (247 % of its initial value) and the lowest Y-NO3 (-) 0.53 ± 0.01 at 150 mg m-cresol-C L(-1). m-Cresol induced a significant decrease in the values of both specific rates of ammonium and nitrite oxidation, being the ammonium oxidation pathway the mainly inhibited. The nitrifying sludge was able to completely oxidize up to 150 mg m-cresol-C L(-1) by SBR cycle, reaching a maximum specific removal rate of 6.45 g m-cresol g(-1) microbial protein-N h(-1). The number of SBR cycles allowed a metabolic adaptation of the nitrifying consortium since nitrification inhibition decreased and faster oxidation of m-cresol took place throughout the cycles.
NASA Astrophysics Data System (ADS)
Ebrahimi-Gatkash, Mehdi; Younesi, Habibollah; Shahbazi, Afsaneh; Heidari, Ava
2017-07-01
In the present study, amino-functionalized Mobil Composite Material No. 41 (MCM-41) was used as an adsorbent to remove nitrate anions from aqueous solutions. Mono-, di- and tri-amino functioned silicas (N-MCM-41, NN-MCM-41 and NNN-MCM-41) were prepared by post-synthesis grafting method. The samples were characterized by means of X-ray powder diffraction, FTIR spectroscopy, thermogravimetric analysis, scanning electron microscopy and nitrogen adsorption-desorption. The effects of pH, initial concentration of anions, and adsorbent loading were examined in batch adsorption system. Results of adsorption experiments showed that the adsorption capacity increased with increasing adsorbent loading and initial anion concentration. It was found that the Langmuir mathematical model indicated better fit to the experimental data than the Freundlich. According to the constants of the Langmuir equation, the maximum adsorption capacity for nitrate anion by N-MCM-41, NN-MCM-41 and NNN-MCM-41 was found to be 31.68, 38.58 and 36.81 mg/g, respectively. The adsorption kinetics were investigated with pseudo-first-order and pseudo-second-order model. Adsorption followed the pseudo-second-order rate kinetics. The coefficients of determination for pseudo-second-order kinetic model are >0.99. For continuous adsorption experiments, NNN-MCM-41 adsorbent was used for the removal of nitrate anion from solutions. Breakthrough curves were investigated at different bed heights, flow rates and initial nitrate anion concentrations. The Thomas and Yan models were utilized to calculate the kinetic parameters and to predict the breakthrough curves of different bed height. Results from this study illustrated the potential utility of these adsorbents for nitrate removal from water solution.
Zimmermann, Markus; Bein, Thomas; Arlt, Matthias; Philipp, Alois; Rupprecht, Leopold; Mueller, Thomas; Lubnow, Matthias; Graf, Bernhard M; Schlitt, Hans J
2009-01-01
Pumpless interventional lung assist (iLA) is used in patients with acute respiratory distress syndrome (ARDS) aimed at improving extracorporeal gas exchange with a membrane integrated in a passive arteriovenous shunt. In previous studies, feasibility and safety of the iLA system was demonstrated, but no survival benefit was observed. In the present pilot study we tested the hypothesis that timely initiation of iLA using clear algorithms and an improved cannulation technique will positively influence complication rates and management of lung protective ventilation. iLA was implemented in 51 patients from multiple aetiologies meeting ARDS-criteria (American-European Consensus) for more than 12 hours. Initiation of iLA followed an algorithm for screening, careful evaluation and insertion technique. Patients with cardiac insufficiency or severe peripheral vascular disease were not considered suitable for iLA. Arterial and venous cannulae were inserted using a new strategy (ultrasound evaluation of vessels by an experienced team, using cannulae of reduced diameter). The incidence of complications and the effects on tidal volumes and inspiratory plateau pressures were primary outcome parameters, while oxygenation improvement and carbon dioxide removal capabilities were secondary study parameters. Initiation of iLA resulted in a marked removal in arterial carbon dioxide allowing a rapid reduction in tidal volume (
Treatment of wastewater containing o-phenylenediamine by ozone in a rotor-stator reactor.
Arowo, Moses; Li, Yingwen; Chu, Guangwen; Sun, Baochang; Chen, Jianfeng; Shao, Lei
2016-01-01
This work employed a novel rotor-stator reactor (RSR) to intensify the degradation process of o-phenylenediamine (o-PDA) by ozone. The effects of different operating parameters including initial pH, temperature, rotation speed, liquid volumetric flow rate and inlet ozone concentration on the removal efficiency of o-PDA were investigated in an attempt to establish the optimum conditions. The removal efficiency was evaluated in terms of degradation ratio and chemical oxygen demand (COD) reduction ratio of the o-PDA wastewater. Results indicate that the removal efficiency decreased with increasing liquid volumetric flow rate but increased with an increase in pH and inlet ozone concentration. Also, the removal efficiency increased up to a certain level with an increase in rotation speed and temperature. Additionally, a comparison experiment was carried out in a stirred tank reactor (STR), and the results show that the degradation and COD reduction ratios reached a maximum of 94.6% and 61.2% in the RSR as compared to 45.3% and 28.6% in the STR, respectively. This work demonstrates that ozone oxidation carried out in RSR may be a promising alternative for pre-treatment of o-PDA wastewater.
Ryu, Byung-Gon; Kim, Woong; Heo, Sung-Woon; Kim, Donghyun; Choi, Gang-Guk; Yang, Ji-Won
2015-09-01
This work describes the development of a microalga-mediated process for simultaneous removal of residual ammonium nitrogen (NH4(+)-N) and production of lipids from biologically treated coke effluent. Four species of green algae were tested using a sequential mixotrophic process. In the first phase-CO2-supplied mixotrophic condition-all microalgae assimilated NH4(+)-N with no evident inhibition. In second phase-volatile fatty acids (VFAs)-supplied mixotrophic condition-removal rates of NH4(+)-N and biomass significantly increased. Among the microalgae used, Arctic Chlorella sp. ArM0029B had the highest rate of NH4(+)-N removal (0.97 mg/L/h) and fatty acid production (24.9 mg/L/d) which were 3.6- and 2.1-fold higher than those observed under the CO2-supplied mixotrophic condition. Redundancy analysis (RDA) indicated that acetate and butyrate were decisive factors for increasing NH4(+)-N removal and fatty acid production. These results demonstrate that microalgae can be used in a sequential process for treatment of residual nitrogen after initial treatment of activated sludge. Copyright © 2015 Elsevier Ltd. All rights reserved.
Removal of Fast Flowing Nitrogen from Marshes Restored in Sandy Soils
Sparks, Eric L.; Cebrian, Just; Smith, Sara M.
2014-01-01
Groundwater flow rates and nitrate removal capacity from an introduced solution were examined for five marsh restoration designs and unvegetated plots shortly after planting and 1 year post-planting. The restoration site was a sandy beach with a wave-dampening fence 10 m offshore. Simulated groundwater flow into the marsh was introduced at a rate to mimic intense rainfall events. Restoration designs varied in initial planting density and corresponded to 25%, 50%, 75% and 100% of the plot area planted. In general, groundwater flow was slower with increasing planting density and decreased from year 0 to year 1 across all treatments. Nevertheless, removal of nitrate from the introduced solution was similar and low for all restoration designs (3–7%) and similar to the unvegetated plots. We suggest that the low NO3 − removal was due to sandy sediments allowing rapid flow of groundwater through the marsh rhizosphere, thereby decreasing the contact time of the NO3 − with the marsh biota. Our findings demonstrate that knowledge of the groundwater flow regime for restoration projects is essential when nutrient filtration is a target goal of the project. PMID:25353607
Removal of Congo red dye from aqueous solutions using a halloysite-magnetite-based composite.
Ferrarini, F; Bonetto, L R; Crespo, Janaina S; Giovanela, M
2016-01-01
Adsorption has been considered as one of the most effective methods to remove dyes from aqueous solutions due to its ease of operation, high efficiency and wide adaptability. In view of all these aspects, this study aimed to evaluate the adsorption capacity of a halloysite-magnetite-based composite in the removal of Congo red dye from aqueous solutions. The effects of stirring rate, pH, initial dye concentration and contact time were investigated. The results revealed that the adsorption kinetics followed the pseudo-second-order model, and equilibrium was well represented by the Brunauer-Emmett-Teller isotherm. The thermodynamic data showed that dye adsorption onto the composite was spontaneous and endothermic and occurred by physisorption. Finally, the composite could also be regenerated at least four times by calcination and was shown to be a promising adsorbent for the removal of this dye.
Internal load management in eutrophic, anoxic environments. The role of natural zeolite.
NASA Astrophysics Data System (ADS)
Gianni, Areti; Zacharias, Ierotheos
2015-04-01
During the last decades, the increase of the nutrient and organic load inflows in the coastal zone increased the number of the anoxic environments. Inputs' control constitutes one of the basic practices for the eutrophic/anoxic aquatic ecosystems management. However, the induced changes at the ecosystem characteristics resulting from the trophic state alteration, and anoxic conditions prevalence, render the ecosystem's restoration difficult if not impossible. Bottom water anoxia accelerates PO43-, NH4+ and S2- recycling and accumulation from organic matter decomposition. This, toxic layer is a permanent menace for the balance of the entire ecosystem, as it can supply PO43-, NH4+ and S2- to the surface layers altering their qualitative character and threatening the welfare of fishes and other aquatic organisms. Having as objective the water basins' internal load control and based on practices are used in eutrophic environments' restoration, this study is referred to the role of the natural zeolite in eutrophic/anoxic ecosystems management. For the first time are presented, results from S2- removal experiments using the zeolitic mineral mordenite, [(Na2, Ca, K2)4 (H2O)28] [Al8Si40O96]. Four different sets of experiments were conducted, in order to examine zeolite's removal capacity of S2- in aquatic solutions, under a wide range of physicochemical parameters. More specific: a) the effect of initial pH on the removal process, b) the removal process kinetics, c) the removal process isotherms and d) the effect of salinity on the removal process were studied. Natural zeolite has the ability to neutralize the pH of aqueous solutions, thus all the experiments were practically performed at pH 7. Initially sulfides concentration range from 1 to 10mg/l. Zeolite's removal capability appeared to be directly depended on the S2- initial concentration. For initial concentration of 1mg/l, the removal rate reached up to 90% after 24h. The maximum zeolite removal capacity was calculated equal to 123.1 10-3 mg/g S2-. Zeolite removal capacity varied by about 10% as the solution's salinity varied from 0 to 35‰. This study emphasizes in the zeolite ability to remove dissolved sulfides from aqueous solutions. According to literature, natural zeolite is particularly effective in removing ammonium from aquatic solutions, while due to its negative charge zeolite doesn't adsorb phosphate ions. However, in the presence of cations (Ca+2, Na+, K+) in the aquatic solution it turns to the appropriate substrate for the formed phosphate salts. In conclusion, zeolite is a natural inert material, capable to remove from aqueous solutions forms of nitrogen, phosphorus and sulfur. Due to this ability zeolite could play a key role, in eutrophic/anoxic environments restoration efforts, since PO43-, NH4+ and H2S constitute the three aspects of the problem called anoxic basins' internal load.
Chau, Destiny F; Vasilopoulos, Terrie; Schoepf, Miriam; Zhang, Christina; Fahy, Brenda G
2016-09-01
Complex surgical and critically ill pediatric patients rely on syringe infusion pumps for precise delivery of IV medications. Low flow rates and in-line IV filter use may affect drug delivery. To determine the effects of an in-line filter to remove air and/or contaminants on syringe pump performance at low flow rates, we compared the measured rates with the programmed flow rates with and without in-line IV filters. Standardized IV infusion assemblies with and without IV filters (filter and control groups) attached to a 10-mL syringe were primed and then loaded onto a syringe pump and connected to a 16-gauge, 16-cm single-lumen catheter. The catheter was suspended in a normal saline fluid column to simulate the back pressure from central venous circulation. The delivered infusate was measured by gravimetric methods at predetermined time intervals, and flow rate was calculated. Experimental trials for initial programmed rates of 1.0, 0.8, 0.6, and 0.4 mL/h were performed in control and filter groups. For each trial, the flow rate was changed to double the initial flow rate and was then returned to the initial flow rate to analyze pump performance for titration of rates often required during medication administration. These conditions (initial rate, doubling of initial rate, and return to initial rate) were analyzed separately for steady-state flow rate and time to steady state, whereas their average was used for percent deviation analysis. Differences between control and filter groups were assessed using Student t tests with adjustment for multiplicity (using n = 3 replications per group). Mean time from 0 to initial flow (startup delay) was <1 minute in both groups with no statistical difference between groups (P = 1.0). The average time to reach steady-state flow after infusion startup or rate changes was not statistically different between the groups (range, 0.8-5.5 minutes), for any flow rate or part of the trial (initial rate, doubling of initial rate, and return to initial rate), although the study was underpowered to detect small time differences. Overall, the mean steady-state flow rate for each trial was below the programmed flow rate with negative mean percent deviations for each trial. In the 1.0-mL/h initial rate trial, the steady-state flow rate attained was lower in the filter than the control group for the initial rate (P = 0.04) and doubling of initial rate (P = 0.04) with a trend during the return to initial rate (P = 0.06), although this same effect was not observed when doubling the initial rate trials of 0.8 or 0.6 mL/h or any other rate trials compared with the control group. With low flow rates used in complex surgical and pediatric critically ill patients, the addition of IV filters did not confer statistically significant changes in startup delay, flow variability, or time to reach steady-state flow of medications administered by syringe infusion pumps. The overall flow rate was lower than programmed flow rate with or without a filter.
Huang, Tinglin; Guo, Lin; Zhang, Haihan; Su, Junfeng; Wen, Gang; Zhang, Kai
2015-11-01
An aerobic denitrifier, identified as Pseudomonas stutzeri strain ZF31, was isolated from the Zhoucun drinking-water reservoir. Strain ZF31 removed 97% of nitrate nitrogen after 16h, without nitrite accumulation. Sequence amplification indicated the presence of the denitrification genes napA, nirS, norB, and nosZ. Nitrogen balance analysis revealed that approximately 75% of the initial nitrogen was removed as gas products. Response surface methodology (RSM) experiments showed that maximum removal of total nitrogen (TN) occurred at pH 8.23, a C/N ratio of 6.68, temperature of 27.72°C, and with shaking at 54.15rpm. The TN removal rate at low C/N ratio (i.e., 3) and low temperature (i.e., 10°C) was 73.30% and 60.08%, respectively. These results suggest that strain ZF31 has potential applications for the bioremediation of slightly polluted drinking-water reservoirs. Copyright © 2015 Elsevier Ltd. All rights reserved.
He, Tengxia; Li, Zhenlun; Sun, Quan; Xu, Yi; Ye, Qing
2016-01-01
A hypothermia aerobic nitrite-denitrifying bacterium, Pseudomonas tolaasii strain Y-11, was found to display high removal capabilities for heterotrophic nitrification with ammonium and for aerobic denitrification with nitrate or nitrite nitrogen. When strain Y-11 was cultivated for 4days at 15°C with the initial ammonium, nitrate and nitrite nitrogen concentrations of 209.62, 204.61 and 204.33mg/L (pH 7.2), the ammonium, nitrate and nitrite removal efficiencies were 93.6%, 93.5% and 81.9% without nitrite accumulation, and the corresponding removal rates reached as high as 2.04, 1.99 and 1.74mg/L/h, respectively. Additionally, ammonium was removed mainly during the simultaneous nitrification and denitrification process. All results demonstrate that P. tolaasii strain Y-11 has the particularity to remove ammonium, nitrate and nitrite nitrogen at low temperatures, which guarantees it for future application in winter wastewater treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hsing, Hao-Jan; Chiang, Pen-Chi; Chang, E-E; Chen, Mei-Yin
2007-03-06
The comparison of different advanced oxidation processes (AOPs), i.e. ultraviolet (UV)/TiO(2), O(3), O(3)/UV, O(3)/UV/TiO(2), Fenton and electrocoagulation (EC), is of interest to determine the best removal performance for the destruction of the target compound in an Acid Orange 6 (AO6) solution, exploring the most efficient experimental conditions as well; on the other hand, the results may provide baseline information of the combination of different AOPs in treating industrial wastewater. The following conclusions can be drawn: (1) in the effects of individual and combined ozonation and photocatalytic UV irradiation, both O(3)/UV and O(3)/UV/TiO(2) processes exhibit remarkable TOC removal capability that can achieve a 65% removal efficiency at pH 7 and O(3) dose=45mg/L; (2) the optimum pH and ratio of [H(2)O(2)]/[Fe(2+)] found for the Fenton process, are pH 4 and [H(2)O(2)]/[Fe(2+)]=6.58. The optimum [H(2)O(2)] and [Fe(2+)] under the same HF value are 58.82 and 8.93mM, respectively; (3) the optimum applied voltage found in the EC experiment is 80V, and the initial pH will affect the AO6 and TOC removal rates in that acidic conditions may be favorable for a higher removal rate; (4) the AO6 decolorization rate ranking was obtained in the order of O(3)
Lucchetti, Roberta; Siciliano, Antonietta; Clarizia, Laura; Russo, Danilo; Di Somma, Ilaria; Di Natale, Francesco; Guida, Marco; Andreozzi, Roberto; Marotta, Raffaele
2017-02-01
The photocatalytic removal of nitrate with simultaneous hydrogen generation was demonstrated using zero-valent nano-copper-modified titania (P25) as photocatalyst in the presence of UV-A-Vis radiation. Glycerol, a by-product in biodiesel production, was chosen as a hole scavenger. Under the adopted experimental conditions, a nitrate removal efficiency up to 100% and a simultaneous hydrogen production up to 14 μmol/L of H 2 were achieved (catalyst load = 150 mg/L, initial concentration of nitrate = 50 mg/L, initial concentration of glycerol = 0.8 mol/L). The reaction rates were independent of the starting glycerol concentration. This process allows accomplishing nitrate removal, with the additional benefit of producing hydrogen under artificial UV-A radiation. A kinetic model was also developed and it may represent a benchmark for a detailed understanding of the process kinetics. A set of acute and chronic bioassays (Vibrio fischeri, Raphidocelis subcapitata, and Daphnia magna) was performed to evaluate the potential ecotoxicity of the nitrate/by-product mixture formed during the photocatalytic process. The ecotoxicological assessment indicated an ecotoxic effect of oxidation intermediates and by-products produced during the process.
Iriel, Analia; Bruneel, Stijn P; Schenone, Nahuel; Cirelli, Alicia Fernández
2018-03-01
The use of natural sorbents to remove fluoride from drinking water is a promising alternative because of its low-cost and easy implementation. In this article, fluoride adsorption on a latosol soil from Misiones province (Argentina) was studied regarding kinetic and equilibrium aspects. Experiments were conducted in batch at room temperature under controlled conditions of pH 4-8) and ionic strength (1-10mM KNO 3 ). Experimental data indicated that adsorption processes followed a PSO kinetic where initial rates have showed to be influenced by pH solution. The necessary time to reach an equilibrium state had resulted approximately 30min. Equilibrium adsorption studies were performed at pH 8 which is similar to the natural groundwater. For that, fluoride adsorption data were successfully adjusted to Dubinin-Ataskhov model determining that the fluoride adsorption onto soil particles mainly followed a physical mechanism with a removal capacity of 0.48mgg -1 . Finally, a natural groundwater was tested with laterite obtaining a reduction close to 30% from initial concentration and without changing significantly the physicochemical properties of the natural water. Therefore, it was concluded that the use of lateritic soils for fluoride removal is very promising on a domestic scale. Copyright © 2017 Elsevier Inc. All rights reserved.
Zekker, Ivar; Rikmann, Ergo; Tenno, Toomas; Lemmiksoo, Vallo; Menert, Anne; Loorits, Liis; Vabamäe, Priit; Tomingas, Martin; Tenno, Taavo
2012-07-01
The anammox bacteria were enriched from reject water of anaerobic digestion of municipal wastewater sludge onto moving bed biofilm reactor (MBBR) system carriers-the ones initially containing no biomass (MBBR1) as well as the ones containing nitrifying biomass (MBBR2). Duration of start-up periods of the both reactors was similar (about 100 days), but stable total nitrogen (TN) removal efficiency occurred earlier in the system containing nitrifying biomass. Anammox TN removal efficiency of 70% was achieved by 180 days in both 20 l volume reactors at moderate temperature of 26.0°C. During the steady state phase of operation of MBBRs the average TN removal efficiencies and maximum TN removal rates in MBBR1 were 80% (1,000 g-N/m(3)/day, achieved by 308 days) and in MBBR2 85% (1,100 g-N/m(3)/day, achieved by 266 days). In both reactors mixed bacterial cultures were detected. Uncultured Planctomycetales bacterium clone P4, Candidatus Nitrospira defluvii and uncultured Nitrospira sp. clone 53 were identified by PCR-DGGE from the system initially containing blank biofilm carriers as well as from the nitrifying biofilm system; from the latter in addition to these also uncultured ammonium oxidizing bacterium clone W1 and Nitrospira sp. clone S1-62 were detected. FISH analysis revealed that anammox microorganisms were located in clusters in the biofilm. Using previously grown nitrifying biofilm matrix for anammox enrichment has some benefits over starting up the process from zero, such as less time for enrichment and protection against severe inhibitions in case of high substrate loading rates.
Lin, Chi-Chang; Yang, Ming-Chien
2003-05-01
The surface of polyacrylonitrile hollow fibers was hydrolyzed and covalently bonded with urease via glutaraldehyde. Immobilized urease retained higher relative activity than native urease when storing at various pHs. The stabilities of immobilized urease to pH were higher than those of native enzyme. Immobilized urease retained 86% of initial activity after reusing 15 times at pH 7. After storing for 42d at 4 degrees C and pH 7, the immobilized urease can hydrolyze 15% of initial concentration of urea at pH 7 and 37 degrees C after 4h, while native urease lost almost its catalytic ability. The removal of urea using urease-immobilized dialyzer was demonstrated with in vitro dialysis and showed faster removing rate of urea than a regular dialyzer by 2 times. Furthermore, the improvement in the urea clearance by the urease immobilization to a dialyzer increased with the dialysate velocity.
Li, Yan; Li, Bing; Wang, Cui-Ping; Fan, Jun-Zhao; Sun, Hong-Wen
2014-01-01
Trichloroethylene (TCE) is a common groundwater contaminant of toxic and carcinogenic concern. Aerobic co-metabolic processes are the predominant pathways for TCE complete degradation. In this study, Pseudomonas fluorescens was studied as the active microorganism to degrade TCE under aerobic condition by co-metabolic degradation using phenol and gasoline as growth substrates. Operating conditions influencing TCE degradation efficiency were optimized. TCE co-metabolic degradation rate reached the maximum of 80% under the optimized conditions of degradation time of 3 days, initial OD600 of microorganism culture of 0.14 (1.26 × 107 cell/mL), initial phenol concentration of 100 mg/L, initial TCE concentration of 0.1 mg/L, pH of 6.0, and salinity of 0.1%. The modified transformation capacity and transformation yield were 20 μg (TCE)/mg (biomass) and 5.1 μg (TCE)/mg (phenol), respectively. Addition of nutrient broth promoted TCE degradation with phenol as growth substrate. It was revealed that catechol 1,2-dioxygenase played an important role in TCE co-metabolism. The dechlorination of TCE was complete, and less chlorinated products were not detected at the end of the experiment. TCE could also be co-metabolized in the presence of gasoline; however, the degradation rate was not high (28%). When phenol was introduced into the system of TCE and gasoline, TCE and gasoline could be removed at substantial rates (up to 59% and 69%, respectively). This study provides a promising approach for the removal of combined pollution of TCE and gasoline. PMID:24857922
Li, Yan; Li, Bing; Wang, Cui-Ping; Fan, Jun-Zhao; Sun, Hong-Wen
2014-05-22
Trichloroethylene (TCE) is a common groundwater contaminant of toxic and carcinogenic concern. Aerobic co-metabolic processes are the predominant pathways for TCE complete degradation. In this study, Pseudomonas fluorescens was studied as the active microorganism to degrade TCE under aerobic condition by co-metabolic degradation using phenol and gasoline as growth substrates. Operating conditions influencing TCE degradation efficiency were optimized. TCE co-metabolic degradation rate reached the maximum of 80% under the optimized conditions of degradation time of 3 days, initial OD600 of microorganism culture of 0.14 (1.26×10⁷ cell/mL), initial phenol concentration of 100 mg/L, initial TCE concentration of 0.1 mg/L, pH of 6.0, and salinity of 0.1%. The modified transformation capacity and transformation yield were 20 μg (TCE)/mg (biomass) and 5.1 μg (TCE)/mg (phenol), respectively. Addition of nutrient broth promoted TCE degradation with phenol as growth substrate. It was revealed that catechol 1,2-dioxygenase played an important role in TCE co-metabolism. The dechlorination of TCE was complete, and less chlorinated products were not detected at the end of the experiment. TCE could also be co-metabolized in the presence of gasoline; however, the degradation rate was not high (28%). When phenol was introduced into the system of TCE and gasoline, TCE and gasoline could be removed at substantial rates (up to 59% and 69%, respectively). This study provides a promising approach for the removal of combined pollution of TCE and gasoline.
Pilot scale test of a produced water-treatment system for initial removal of organic compounds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, Enid J; Kwon, Soondong; Katz, Lynn
A pilot-scale test to remove polar and non-polar organics from produced water was performed at a disposal facility in Farmington NM. We used surfactant-modified zeolite (SMZ) adsorbent beds and a membrane bioreactor (MBR) in combination to reduce the organic carbon content of produced water prior to reverse osmosis (RO). Reduction of total influent organic carbon (TOC) to 5 mg/L or less is desirable for efficient RO system operation. Most water disposed at the facility is from coal-bed gas production, with oil production waters intermixed. Up to 20 gal/d of produced water was cycled through two SMZ adsorbent units to removemore » volatile organic compounds (BTEX, acetone) and semivolatile organic compounds (e.g., napthalene). Output water from the SMZ units was sent to the MBR for removal of the organic acid component of TOC. Removal of inorganic (Mn and Fe oxide) particulates by the SMZ system was observed. The SMZ columns removed up to 40% of the influent TOC (600 mg/L). BTEX concentrations were reduced from the initial input of 70 mg/L to 5 mg/L by the SMZ and to an average of 2 mg/L after the MBR. Removal rates of acetate (input 120-170 mg/L) and TOC (input up to 45 mg/L) were up to 100% and 92%, respectively. The water pH rose from 8.5 to 8.8 following organic acid removal in the MBR; this relatively high pH was likely responsible for observed scaling of the MBR internal membrane. Additional laboratory studies showed the scaling can be reduced by metered addition of acid to reduce the pH. Significantly, organic removal in the MBR was accomplished with a very low biomass concentration of 1 g/L throughout the field trial. An earlier engineering evaluation shows produced water treatment by the SMZ/MBR/RO system would cost from $0.13 to $0.20 per bbl at up to 40 gpm. Current estimated disposal costs for produced water are $1.75 to $4.91 per bbl when transportation costs are included, with even higher rates in some regions. Our results suggest that treatment by an SMZ/MBR/RO system may be a feasible alternative to current methods for produced water treatment and disposal.« less
Jeon, Jin Hee; Kim, Sang Done; Lim, Tak Hyoung; Lee, Dong Hyun
2005-08-01
The effects of initial trichloroethylene (TCE) concentration, recirculating liquid flow rate and gas velocity on photodegradation of TCE have been determined in an internally circulating slurry bubble column reactor (0.15m-ID x 0.85 m-high). Titanium dioxide (TiO2) powder was employed as a photocatalyst and the optimum loading of TiO2 in the present system is found to be approximately 0.2 wt%. The stripping fraction of TCE by air flow increases but photodegradation fraction of TCE decreases with increasing the initial TCE concentration, recirculating liquid flow rate and gas velocity. The average removal efficiency of TCE is found to be approximately 97% in an internally circulating slurry bubble column reactor.
How UV photolysis accelerates the biodegradation and mineralization of sulfadiazine (SD).
Pan, Shihui; Yan, Ning; Liu, Xinyue; Wang, Wenbing; Zhang, Yongming; Liu, Rui; Rittmann, Bruce E
2014-11-01
Sulfadiazine (SD), one of broad-spectrum antibiotics, exhibits limited biodegradation in wastewater treatment due to its chemical structure, which requires initial mono-oxygenation reactions to initiate its biodegradation. Intimately coupling UV photolysis with biodegradation, realized with the internal loop photobiodegradation reactor, accelerated SD biodegradation and mineralization by 35 and 71 %, respectively. The main organic products from photolysis were 2-aminopyrimidine (2-AP), p-aminobenzenesulfonic acid (ABS), and aniline (An), and an SD-photolysis pathway could be identified using C, N, and S balances. Adding An or ABS (but not 2-AP) into the SD solution during biodegradation experiments (no UV photolysis) gave SD removal and mineralization rates similar to intimately coupled photolysis and biodegradation. An SD biodegradation pathway, based on a diverse set of the experimental results, explains how the mineralization of ABS and An (but not 2-AP) provided internal electron carriers that accelerated the initial mono-oxygenation reactions of SD biodegradation. Thus, multiple lines of evidence support that the mechanism by which intimately coupled photolysis and biodegradation accelerated SD removal and mineralization was through producing co-substrates whose oxidation produced electron equivalents that stimulated the initial mono-oxygenation reactions for SD biodegradation.
Iron crystallization in a fluidized-bed Fenton process.
Boonrattanakij, Nonglak; Lu, Ming-Chun; Anotai, Jin
2011-05-01
The mechanisms of iron precipitation and crystallization in a fluidized-bed reactor were investigated. Within the typical Fenton's reagent dosage and pH range, ferric ions as a product from ferrous ion oxidation would be supersaturated and would subsequently precipitate out in the form of ferric hydroxide after the initiation of the Fenton reaction. These precipitates would simultaneously crystallize onto solid particles in a fluidized-bed Fenton reactor if the precipitation proceeded toward heterogeneous nucleation. The heterogeneous crystallization rate was controlled by the fluidized material type and the aging/ripening period of the crystallites. Iron crystallization onto the construction sand was faster than onto SiO(2), although the iron removal efficiencies at 180 min, which was principally controlled by iron hydroxide solubility, were comparable. To achieve a high iron removal rate, fluidized materials have to be present at the beginning of the Fenton reaction. Organic intermediates that can form ferro-complexes, particularly volatile fatty acids, can significantly increase ferric ion solubility, hence reducing the crystallization performance. Therefore, the fluidized-bed Fenton process will achieve exceptional performance with respect to both organic pollutant removal and iron removal if it is operated with the goal of complete mineralization. Crystallized iron on the fluidized media could slightly retard the successive crystallization rate; thus, it is necessary to continuously replace a portion of the iron-coated bed with fresh media to maintain iron removal performance. The iron-coated construction sand also had a catalytic property, though was less than those of commercial goethite. Copyright © 2011 Elsevier Ltd. All rights reserved.
Enhancing the efficiency of zero valent iron by electrolysis: Performance and reaction mechanism.
Xiong, Zhaokun; Lai, Bo; Yang, Ping
2018-03-01
Electrolysis was applied to enhance the efficiency of micron-size zero valent iron (mFe 0 ) and thereby promote p-nitrophenol (PNP) removal. The rate of PNP removal by mFe 0 with electrolysis was determined in cylindrical electrolysis reactor that employed annular aluminum plate cathode as a function of experimental factors, including initial pH, mFe 0 dosage and current density. The rate constants of PNP removal by Ele-mFe 0 were 1.72-144.50-fold greater than those by pristine mFe 0 under various tested conditions. The electrolysis-induced improvement could be primarily ascribed to stimulated mFe 0 corrosion, as evidenced by Fe 2+ release. The application of electrolysis could extend the working pH range of mFe 0 from 3.0 to 6.0 to 3.0-10.0 for PNP removal. Additionally, intermediates analysis and scavengers experiments unraveled the reduction capacity of mFe 0 was accelerated in the presence of electrolysis instead of oxidation. Moreover, the electrolysis effect could also delay passivation of mFe 0 under acidic condition, as evidenced by SEM-EDS, XRD, and XPS analysis after long-term operation. This is mainly due to increased electromigration meaning that iron corrosion products (iron hydroxides and oxides) are not primarily formed in the vicinity of the mFe 0 or at its surface. In the presence of electrolysis, the effect of electric field significantly promoted the efficiency of electromigration, thereby enhanced mFe 0 corrosion and eventually accelerated the PNP removal rates. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cotillas, Salvador; Llanos, Javier; Cañizares, Pablo; Mateo, Sara; Rodrigo, Manuel A
2013-04-01
In this work, a novel integrated electrochemical process for urban wastewater regeneration is described. The electrochemical cell consists in a Boron Doped Diamond (BDD) or a Dimensionally Stable Anode (DSA) as anode, a Stainless Steel (SS) as cathode and a perforated aluminum plate, which behaves as bipolar electrode, between anode and cathode. Thus, in this cell, it is possible to carry out, at the same time, two different electrochemical processes: electrodisinfection (ED) and electrocoagulation (EC). The treatment of urban wastewater with different anodes and different operating conditions is studied. First of all, in order to check the process performance, experiments with synthetic wastewaters were carried out, showing that it is possible to achieve a 100% of turbidity removal by the electrodissolution of the bipolar electrode. Next, the effect of the current density and the anode material are studied during the ED-EC process of actual effluents. Results show that it is possible to remove Escherichia coli and turbidity simultaneously of an actual effluent from a WasteWater Treatment Facility (WWTF). The use of BDD anodes allows to remove the E. coli completely at an applied electric charge of 0.0077 A h dm(-3) when working with a current density of 6.65 A m(-2). On the other hand, with DSA anodes, the current density necessary to achieve the total removal of E. coli is higher (11.12 A m(-2)) than that required with BDD anodes. Finally, the influence of cell flow path and flow rate have been studied. Results show that the performance of the process strongly depends on the characteristics of the initial effluent (E. coli concentration and Cl(-)/NH(4)(+) initial ratio) and that a cell configuration cathode (inlet)-anode (outlet) and a higher flow rate enhance the removal of the turbidity from the treated effluent. Copyright © 2013 Elsevier Ltd. All rights reserved.
Franklin, Craig E; Seebacher, Frank
2003-04-01
The effect of heating and cooling on heart rate in the estuarine crocodile Crocodylus porosus was studied in response to different heat transfer mechanisms and heat loads. Three heating treatments were investigated. C. porosus were: (1) exposed to a radiant heat source under dry conditions; (2) heated via radiant energy while half-submerged in flowing water at 23 degrees C and (3) heated via convective transfer by increasing water temperature from 23 degrees C to 35 degrees C. Cooling was achieved in all treatments by removing the heat source and with C. porosus half-submerged in flowing water at 23 degrees C. In all treatments, the heart rate of C. porosus increased markedly in response to heating and decreased rapidly with the removal of the heat source. Heart rate during heating was significantly faster than during cooling at any given body temperature, i.e. there was a significant heart rate hysteresis. There were two identifiable responses to heating and cooling. During the initial stages of applying or removing the heat source, there was a dramatic increase or decrease in heart rate ('rapid response'), respectively, indicating a possible cardiac reflex. This rapid change in heart rate with only a small change or no change in body temperature (<0.5 degrees C) resulted in Q(10) values greater than 4000, calling into question the usefulness of this measure on heart rate during the initial stages of heating and cooling. In the later phases of heating and cooling, heart rate changed with body temperature, with Q(10) values of 2-3. The magnitude of the heart rate response differed between treatments, with radiant heating during submergence eliciting the smallest response. The heart rate of C. porosus outside of the 'rapid response' periods was found to be a function of the heat load experienced at the animal surface, as well as on the mode of heat transfer. Heart rate increased or decreased rapidly when C. porosus experienced large positive (above 25 W) or negative (below -15 W) heat loads, respectively, in all treatments. For heat loads between -15 W and 20 W, the increase in heart rate was smaller for the 'unnatural' heating by convection in water compared with either treatment using radiant heating. Our data indicate that changes in heart rate constitute a thermoregulatory mechanism that is modulated in response to the thermal environment occupied by the animal, but that heart rate during heating and cooling is, in part, controlled independently of body temperature.
Mohamad, Osama Abdalla; Hao, Xiuli; Xie, Pin; Hatab, Shaimaa; Lin, Yanbing; Wei, Gehong
2012-01-01
The mining industry generates huge amounts of wastewater, containing toxic heavy metals. Treatment to remove heavy metals is necessary and recent work has been focused on finding more environmentally friendly materials for removing heavy metals from wastewater. Biosorption can be an effective process for heavy metal removal from aqueous solutions. Our objectives were to investigate the removal of copper (II) from aqueous solutions using dead cells of Mesorhizobium amorphae CCNWGS0123 under differing levels of pH, agitation speed, temperature, initial copper concentration, biosorbent dose and contact time using flame atomic absorption spectroscopy for metal estimation. The maximum copper removal rate was achieved at pH 5.0, agitation speed 150×g, temperature 28°C and initial Cu (II) concentration of 100 mg L−1. Maximum biosorption capacity was at 0.5 g L−1 and equilibrium was attained within 30 min. Langmuir and Freundlich isotherms showed correlation coefficients of 0.958 and 0.934, respectively. Fourier transform-infrared spectroscopy (FT-IR) analysis indicated that many functional groups, such as O-H, N-H, C-H, C=O, -NH, -CN, C-N, C-O, amide -I, -II, -III and unsaturated alkenes, alkyls and aromatic groups on the cell surface were involved in the interaction between CCNWGS0123 and Cu. Scanning electron microscope and energy dispersive X-ray scanning results showed deformation, aggregation, and cell-surface damage due to the precipitation of copper on the cell surface. Dead cells of CCNWGS0123 showed potential as an efficient biosorbent for the removal of Cu2+ from aqueous solutions. PMID:22353770
Xu, Jie; Wang, Xue; Sun, Shiqing; Zhao, Yongjun; Hu, Changwei
2017-09-07
Three different treatment technologies, namely mono-algae culture, algal-bacterial culture, and algal-fungal culture, were applied to remove pollutants form synthetic domestic sewage and to remove CO 2 from biogas in a photobioreactor. The effects of different initial influent C/N ratios on microalgal growth rates and pollutants removal efficiencies by the three microalgal cultures were investigated. The best biogas upgrading and synthetic domestic sewage pollutants removal effect was achieved in the algal-fungal system at the influent C/N ratio of 5:1. At the influent C/N ratio of 5:1, the algal-fungal system achieved the highest mean chemical oxygen demand (COD) removal efficiency of 81.92% and total phosphorus (TP) removal efficiency of 81.52%, respectively, while the algal-bacterial system demonstrated the highest mean total nitrogen (TN) removal efficiency of 82.28%. The average CH 4 concentration in upgraded biogas and the removal efficiencies of COD, TN, and TP were 93.25 ± 3.84% (v/v), 80.23 ± 3.92%, 75.85 ± 6.61%, and 78.41 ± 3.98%, respectively. These results will provide a reference for wastewater purification ad biogas upgrading with microalgae based technology.
Meng, Pingping; Deng, Shubo; Maimaiti, Ayiguli; Wang, Bin; Huang, Jun; Wang, Yujue; Cousins, Ian T; Yu, Gang
2018-07-01
Aqueous film-forming foams (AFFFs) used in fire-fighting are one of the main contamination sources of perfluorooctane sulfonate (PFOS) to the subterranean environment, requiring high costs for remediation. In this study, a method that combined aeration and foam collection was presented to remove PFOS from a commercially available AFFF solution. The method utilized the strong surfactant properties of PFOS that cause it to be highly enriched at air-water interfaces. With an aeration flow rate of 75 mL/min, PFOS removal percent reached 96% after 2 h, and the PFOS concentration in the collected foam was up to 6.5 mmol/L, beneficial for PFOS recovery and reuse. Increasing the aeration flow rate, ionic strength and concentration of co-existing surfactant, as well as decreasing the initial PFOS concentration, increased the removal percents of PFOS by increasing the foam volume, but reduced the enrichment of PFOS in the foams. With the assistance of a co-existing hydrocarbon surfactant, PFOS removal percent was above 99.9% after aeration-foam collection for 2 h and the enrichment factor exceeded 8400. Aeration-foam collection was less effective for short-chain perfluoroalkyl substances due to their relatively lower surface activity. Aeration-foam collection was found to be effective for the removal of high concentrations of PFOS from AFFF-contaminated wastewater, and the concentrated PFOS in the collected foam can be reused. Copyright © 2018 Elsevier Ltd. All rights reserved.
Demographic response of northern spotted owls to barred owl removal
Diller, V. Lowell; Hamm, Keith A; Early, Desiree A; Lamphear, David W; Dugger, Katie M.; Yackulic, Charles B.; Schwarz, Carl J.; Carlson, Peter C.; McDonald, Trent L.
2016-01-01
Federally listed as threatened in 1990 primarily because of habitat loss, the northern spotted owl (Strix occidentalis caurina) has continued to decline despite conservation efforts resulting in forested habitat being reserved throughout its range. Recently, there is growing evidence the congeneric invasive barred owl (Strix varia) may be responsible for the continued decline primarily by excluding spotted owls from their preferred habitat. We used a long-term demographic study for spotted owls in coastal northern California as the basis for a pilot barred owl removal experiment. Our demography study used capture–recapture, reproductive output, and territory occupancy data collected from 1990 to 2013 to evaluate trends in vital rates and populations. We used a classic before-after-control-impact (BACI) experimental design to investigate the demographic response of northern spotted owls to the lethal removal of barred owls. According to the best 2-species dynamic occupancy model, there was no evidence of differences in barred or northern spotted owl occupancy prior to the initiation of the treatment (barred owl removal). After treatment, barred owl occupancy was lower in the treated relative to the untreated areas and spotted owl occupancy was higher relative to the untreated areas. Barred owl removal decreased spotted owl territory extinction rates but did not affect territory colonization rates. As a result, spotted owl occupancy increased in the treated area and continued to decline in the untreated areas. Prior to and after barred owl removal, there was no evidence that average fecundity differed on the 2 study areas. However, the greater number of occupied spotted owl sites on the treated areas resulted in greater productivity in the treated areas based on empirical counts of fledged young. Prior to removal, survival was declining at a rate of approximately 0.2% per year for treated and untreated areas. Following treatment, estimated survival was 0.859 for the treated areas and 0.822 for the untreated areas. Derived estimates of population change on both study areas showed the same general decline before removal with an estimated slope of –0.0036 per year. Following removal, the rate of population change on the treated areas increased to an average of 1.029 but decreased to an average of 0.870 on the untreated areas. The results from this first experiment demonstrated that lethal removal of barred owls allowed the recovery of northern spotted owl populations in the treated portions of our study area. If additional federally funded barred owl removal experiments provide similar results, this could be the foundation for development of a long-term conservation strategy for northern spotted owls.
Biotransformation of tetracycline by a novel bacterial strain Stenotrophomonas maltophilia DT1.
Leng, Yifei; Bao, Jianguo; Chang, Gaofeng; Zheng, Han; Li, Xingxing; Du, Jiangkun; Snow, Daniel; Li, Xu
2016-11-15
Although several abiotic processes have been reported that can transform antibiotics, little is known about whether and how microbiological processes may degrade antibiotics in the environment. This work isolated one tetracycline degrading bacterial strain, Stenotrophomonas maltophilia strain DT1, and characterized the biotransformation of tetracycline by DT1 under various environmental conditions. The biotransformation rate was the highest when the initial pH was 9 and the reaction temperature was at 30°C, and can be described using the Michaelis-Menten model under different initial tetracycline concentrations. When additional substrate was present, the substrate that caused increased biomass resulted in a decreased biotransformation rate of tetracycline. According to disk diffusion tests, the biotransformation products of tetracycline had lower antibiotic potency than the parent compound. Six possible biotransformation products were identified, and a potential biotransformation pathway was proposed that included sequential removal of N-methyl, carbonyl, and amine function groups. Results from this study can lead to better estimation of the fate and transport of antibiotics in the environment and has the potential to be utilized in designing engineering processes to remove tetracycline from water and soil. Copyright © 2016 Elsevier B.V. All rights reserved.
Yang, Yu-Yi; Li, Ze-Li; Wang, Guan; Zhao, Xiao-Ping; Crowley, David E.; Zhao, Yu-Hua
2012-01-01
The performances of nine biosorbents derived from dead fungal biomass were investigated for their ability to remove Reactive Black 5 from aqueous solution. The biosorption data for removal of Reactive Black 5 were readily modeled using the Langmuir adsorption isotherm. Kinetic analysis based on both pseudo-second-order and Weber-Morris models indicated intraparticle diffusion was the rate limiting step for biosorption of Reactive Black 5 on to the biosorbents. Sorption capacities of the biosorbents were not correlated with the initial biosorption rates. Sensitivity analysis of the factors affecting biosorption examined by an artificial neural network model showed that pH was the most important parameter, explaining 22%, followed by nitrogen content of biosorbents (16%), initial dye concentration (15%) and carbon content of biosorbents (10%). The biosorption capacities were not proportional to surface areas of the sorbents, but were instead influenced by their chemical element composition. The main functional groups contributing to dye sorption were amine, carboxylic, and alcohol moieties. The data further suggest that differences in carbon and nitrogen contents of biosorbents may be used as a selection index for identifying effective biosorbents from dead fungal biomass. PMID:22442697
2018-01-01
Electrolysis of toilet wastewater with TiO2-coated semiconductor anodes and stainless steel cathodes is a potentially viable onsite sanitation solution in parts of the world without infrastructure for centralized wastewater treatment. In addition to treating toilet wastewater, pilot-scale and bench-scale experiments demonstrated that electrolysis can remove phosphate by cathodic precipitation as hydroxyapatite at no additional energy cost. Phosphate removal could be predicted based on initial phosphate and calcium concentrations, and up to 80% total phosphate removal was achieved. While calcium was critical for phosphate removal, magnesium and bicarbonate had only minor impacts on phosphate removal rates at concentrations typical of toilet wastewater. Optimal conditions for phosphate removal were 3 to 4 h treatment at about 5 mA cm–2 (∼3.4 V), with greater than 20 m2 m–3 electrode surface area to reactor volume ratios. Pilot-scale systems are currently operated under similar conditions, suggesting that phosphate removal can be viewed as an ancillary benefit of electrochemical wastewater treatment, adding utility to the process without requiring additional energy inputs. Further value may be provided by designing reactors to recover precipitated hydroxyapatite for use as a low solubility phosphorus-rich fertilizer. PMID:29607266
Cid, Clément A; Jasper, Justin T; Hoffmann, Michael R
2018-03-05
Electrolysis of toilet wastewater with TiO 2 -coated semiconductor anodes and stainless steel cathodes is a potentially viable onsite sanitation solution in parts of the world without infrastructure for centralized wastewater treatment. In addition to treating toilet wastewater, pilot-scale and bench-scale experiments demonstrated that electrolysis can remove phosphate by cathodic precipitation as hydroxyapatite at no additional energy cost. Phosphate removal could be predicted based on initial phosphate and calcium concentrations, and up to 80% total phosphate removal was achieved. While calcium was critical for phosphate removal, magnesium and bicarbonate had only minor impacts on phosphate removal rates at concentrations typical of toilet wastewater. Optimal conditions for phosphate removal were 3 to 4 h treatment at about 5 mA cm -2 (∼3.4 V), with greater than 20 m 2 m -3 electrode surface area to reactor volume ratios. Pilot-scale systems are currently operated under similar conditions, suggesting that phosphate removal can be viewed as an ancillary benefit of electrochemical wastewater treatment, adding utility to the process without requiring additional energy inputs. Further value may be provided by designing reactors to recover precipitated hydroxyapatite for use as a low solubility phosphorus-rich fertilizer.
Liu, Lin; Liu, Yu-Hong; Wang, Zhen; Liu, Chao-Xiang; Huang, Xu; Zhu, Ge-Fu
2014-08-15
Four pilot-scale constructed wetlands (free water surface, SF; horizontal subsurface flow, HSF; vertical subsurface flows with different water level, VSF-L and VSF-H) were operated to assess their ability to remove sulfamethazine (SMZ) and tetracycline (TC) from wastewaters, and to investigate the abundance level of corresponding resistance genes (sulI, sulII, tetM, tetW and tetO) in the CWs. The results indicated that CWs could significantly reduce the concentration of antibiotics in wastewater, and the mass removal rate range of SMZ and TC were respectively 11%-95% and 85%-95% in the four systems on the basis of hydraulic equilibrium; further relatively high removal rate was observed in VSF with low water level. Seasonal condition had a significant effect on SMZ removal in the CWs (especially SMZ in SF), but TC removal in VSFs were not considered to have statistically significant differences in winter and summer. At the end period, the relative abundances of target genes in the CWs showed obvious increases compared to initial levels, ranging from 2.98 × 10(-5) to 1.27 × 10(-1) for sul genes and 4.68 × 10(-6) to 1.54 × 10(-1) for tet genes after treatment, and those abundances showed close relation to both characteristic of wastewater and configuration of CWs. Copyright © 2014 Elsevier B.V. All rights reserved.
Kundu, Pradyut; Pramanik, Arnab; Dasgupta, Arpita; Mukherjee, Somnath; Mukherjee, Joydeep
2014-01-01
A heterotrophic carbon utilizing microbe (R31) capable of simultaneous nitrification and denitrification (SND) was isolated from wastewater of an Indian slaughterhouse. From an initial COD value of 583.0 mg/L, 95.54% was removed whilst, from a starting NH4 +-N concentration of 55.7 mg/L, 95.87% was removed after 48 h contact. The concentrations of the intermediates hydroxylamine, nitrite, and nitrate were low, thus ensuring nitrogen removal. Aerobic denitrification occurring during ammonium removal by R31 was confirmed by utilization of both nitrate and nitrite as nitrogen substrates. Glucose and succinate were superior while acetate and citrate were poor substrates for nitrogen removal. Molecular phylogenetic identification, supported by chemotaxonomic and physiological properties, assigned R31 as a close relative of Chryseobacterium haifense. The NH4 +-N utilization rate and growth of strain R31 were found to be higher at C/N = 10 in comparison to those achieved with C/N ratios of 5 and 20. Monod kinetic coefficients, half saturation concentration (K s), maximum rate of substrate utilization (k), yield coefficient, (Y) and endogenous decay coefficient (K d) indicated potential application of R31 in large-scale SND process. This is the first report on concomitant carbon oxidation, nitrification, and denitrification in the genus Chryseobacterium and the associated kinetic coefficients. PMID:24991552
Photochemical Degradation of Organic Pollutants in Wastewaters
NASA Astrophysics Data System (ADS)
Balbayeva, Gaukhar; Yerkinova, Azat; Inglezakis, Vassilis J.; Poulopoulos, Stavros G.
2018-01-01
In the present work, the photochemical treatment of a synthetic wastewater in a batch recycle photochemical reactor using ultraviolet irradiation (254 nm, 6 W), hydrogen peroxide and ferric ions was studied. Reactor volume was 250 mL with 55.8 mL of irradiated volume in the annular photoreactor. The synthetic wastewater was composed mainly of organic carbon. The effect of initial total carbon (136-1080 mg L-1), initial H2O2 amount (1332-5328 mg L-1), pH, and Fe(III) presence (2-40 ppm), on total carbon (TC) removal was studied. Each experiment lasted 120 min, and the process was attended via pH and TC concentration. Direct photolysis in the absence of any oxidant had practically no effect on TC removal. Regarding the effect of initial TC concentration in the wastewater keeping the same initial hydrogen peroxide concentration (2664 mg L-1), it was observed that for 136-271 mg L-1 TC, around 60% TC removal was achieved, while when initial TC was increased at 528 mg L-1, the TC removal observed decreased to 50%. For a further increase in TC at 1080 mg L-1, TC removal dropped to 14%. Initial pH adjustment of the wastewater resulted in slight variations of the TC removals achieved. Finally, adding Fe(III) in the process was beneficial in terms of TC removal obtained. Particularly, the addition of 40 ppm Fe(III) in the presence of 2664 mg L-1 H2O2 and initial TC equal to 528 mg L-1 increased the TC removal from 50% to 72%.
Mechanisms of ilmenite reduction and their impact on the design of effective reactor systems
NASA Technical Reports Server (NTRS)
Briggs, R. A.; Sacco, A.
1991-01-01
One of the first activities at a lunar base could be oxygen recovery from ilmenite (FeTiO3). Oxygen produced from lunar soils could be used to fuel transportation vehicles operating in near-earth space. The first step in developing a suitable reactor system for lunar operation is to determine the mechanisms and rates of oxygen removal from ilmenite. In-situ gravimetric measurements and microscopic examinations were used to determine the hydrogen reduction mechanisms of synthetic ilmenite discs between 823 to 1353 K. A shrinking core reaction model, modified to account for the growth of an iron film on the surface of discs, was capable of predicting experimentally observed conversion-time relationships. The observed reduction mechanism, kinetic rates, and associated activation energy established a base line from which comparisons could be made to improve oxygen yield and removal rates. One proposed technique to improve the rate and extent of oxygen removal was to preoxidize ilmenite. Preoxidation is commonly used during the reduction of ilmenite ores in the iron industry and has been employed for many years to lower operating temperatures and increase reduction rates. This technology could prove beneficial for oxygen production facilities on the Moon as less massive reactor vessels and/or less energy could be associated with a process including preoxidation. X ray diffraction and energy dispersive spectroscopy were utilized to follow the progression of ilmenite oxidation at 1123 and 1140 K and the reduction of pseudobrookite (Fe2TiO5) at 873 and 973 K. Structures formed during the progress of oxidation were related to the system's phase diagrams. Results indicated that after initially producing ilmenite-hematite solutions and rutile (TiO2), pseudobrookite was the end product of oxidation at all temperatures examined (1049 to 1273 K). Initial results from the reduction of pseudobrookite indicate a series of phases are produced including ferropseudobrookite (FeTi2O5), ulvospinel (Fe2TiO4), and ilmenite. Rates of pseudobrookite reduction were typically 50 to 200 times that of ilmenite.
Zhou, Xian-Jiao; Guo, Wan-Qian; Yang, Shan-Shan; Ren, Nan-Qi
2012-02-01
This research set up an ultrasonic-assisted ozone oxidation process (UAOOP) to decolorize the triphenylmethane dyes wastewater. Five factors - temperature, initial pH, reaction time, ultrasonic power (low frequency 20 kHz), and ozone concentration - were investigated. Response surface methodology was used to find out the major factors influencing color removal rate and the interactions between these factors, and optimized the operating parameters as well. Under the experimental conditions: reaction temperature 39.81 °C, initial pH 5.29, ultrasonic power 60 W and ozone concentration 0.17 g/L, the highest color removals were achieved with 10 min reaction time and the initial concentration of the MG solution was 1000 mg/L. The optimal results indicated that the UAOOP was a rapid, efficient and low energy consumption technique to decolorize the high concentration MG wastewater. The predicted model was approximately in accordance with the experimental cases with correlation coefficients R(2) and R(adj)(2) of 0.9103 and 0.8386. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ghaedi, Mehrorang; Kokhdan, Syamak Nasiri
2015-02-01
The use of cheep, non-toxic, safe and easily available adsorbent are efficient and recommended material and alternative to the current expensive substance for pollutant removal from wastewater. The activated carbon prepared from wood waste of local tree (millet) extensively was applied for quantitative removal of methylene blue (MB), while simply. It was used to re-used after heating and washing with alkaline solution of ethanol. This new adsorbent was characterized by using BET surface area measurement, FT-IR, pH determination at zero point of charge (pHZPC) and Boehm titration method. Response surface methodology (RSM) by at least the number of experiments main and interaction of experimental conditions such as pH of solution, contact time, initial dye concentration and adsorbent dosage was optimized and set as pH 7, contact time 18 min, initial dye concentration 20 ppm and 0.2 g of adsorbent. It was found that variable such as pH and amount of adsorbent as solely or combination effects seriously affect the removal percentage. The fitting experimental data with conventional models reveal the applicability of isotherm models Langmuir model for their well presentation and description and Kinetic real rate of adsorption at most conditions efficiently can be represented pseudo-second order, and intra-particle diffusion. It novel material is good candidate for removal of huge amount of MB (20 ppm) in short time (18 min) by consumption of small amount (0.2 g).
Removal of organic matter from a variety of water matrices by UV photolysis and UV/H2O2 method.
Vilhunen, Sari; Vilve, Miia; Vepsäläinen, Mikko; Sillanpää, Mika
2010-07-15
A re-circulated flow-through photoreactor was used to evaluate the ultraviolet (UV) photolysis and UV/H(2)O(2) oxidation process in the purification of three different water matrices. Chemically coagulated and electrocoagulated surface water, groundwater contaminated with creosote wood preservative and 1,2-dichloroethane (DCE) containing washing water from the plant manufacturing tailor-made ion-exchange resins were used as sample waters. The organic constituents of creosote consist mainly of harmful polycyclic aromatic hydrocarbons (PAH) whereas 1,2-DCE is a toxic volatile organic compound (VOC). Besides analyzing the specific target compounds, total organic carbon (TOC) analysis and measurement of change in UV absorbance at 254 nm (UV(254)) were performed. Initial TOC, UV(254) and pH varied significantly among treated waters. Initial H(2)O(2) concentrations 0-200 mg/l were used. The UV/H(2)O(2) treatment was efficient in removing the hazardous target pollutants (PAHs and 1,2-DCE) and natural organic matter (NOM). In addition, high removal efficiency for TOC was achieved for coagulated waters and groundwater. Also, the efficiency of direct photolysis in UV(254) removal was significant except in the treatment of 1,2-DCE containing washing water. Overall, UV(254) and TOC removal rates were high, except in case of washing water, and the target pollutants were efficiently decomposed with the UV/H(2)O(2) method. 2010 Elsevier B.V. All rights reserved.
Perchlorate reduction by autotrophic bacteria in the presence of zero-valent iron.
Yu, Xueyuan; Amrhein, Christopher; Deshusses, Marc A; Matsumoto, Mark R
2006-02-15
A series of batch experiments were performed to study the combination of zero-valent iron (ZVI) with perchlorate-reducing microorganisms (PRMs) to remove perchlorate from groundwater. In this method, H2 produced during the process of iron corrosion by water is used by PRMs as an electron donor to reduce perchlorate to chloride. Perchlorate degradation rates followed Monod kinetics, with a normalized maximum utilization rate (rmax) of 9200 microg g(-1) (dry wt) h(-1) and a half-velocity constant (Ks) of 8900 microg L(-1). The overall rate of perchlorate reduction was affected by the biomass density within the system. An increase in the OD600 from 0.025 to 0.08 led to a corresponding 4-fold increase of perchlorate reduction rate. PRM adaptation to the local environment and initiation of perchlorate reduction was rapid under neutral pH conditions. At the initial OD600 of 0.015, perchlorate reduction followed pseudo-first-order reaction rates with constants of 0.059 and 0.033 h(-1) at initial pH 7 and 8, respectively. Once perchlorate reduction was established, the bioreductive process was insensitive to the increases of pH from near neutral to 9.0. In the presence of nitrate, perchlorate reduction rate was reduced, but not inhibited completely.
Fate and effects of nitrogen and phosphorus in shallow vegetated aquatic ecosystems
Fairchild, James F.; Vradenburg, Leigh Ann
2006-01-01
Nitrate concentrations have greatly increased in streams and rivers draining agricultural regions of the Midwestern United States, increasing nitrate transport to the Gulf of Mexico has been implicated in the hypoxic conditions that threaten the productivity of marine fisheries. Increases in nitrate concentrations have been attributed to a combination of factors including agricultural expansion, increased nitrogen application rates, increased tile drainage, and loss of riparian Wetlands, These landscape-level changes have resulted in a decreased natural capacity for nitrogen uptake, removal, and cycling back to the atmosphere. Land managers are increasingly interested in using wetland construction and rehabilitation as a management practice to reduce loss of nitrate from the terrestrial systems. Yet, relatively little is known about the limnological factors involved in nitrate removal by Wetland systems.We conducted a series of studies from 1999-2000 to investigate the functional capacity of shallow, macrophyte-dominated pond wetland systems for uptake, assimilation, and retention of nitrogen (N) and phosphorus (P). We evaluated four factors that were hypothesized to influence nutrient uptake and assimilation: 1) nitrate loading rates; 2) nitrogen to phosphorus (N.P) ratios; 3) frequency of dosing/application; and 4) timing of dose initiation.Nutrient assimilation was rapid; store than 90% of added nutrients were removed from the water column in all treatments. Neither variation in N:P ratios (evaluated range, <13:1 to -114.1), frequency of application (weekly or bi-weekly), nor liming of dose initiation relative to macrophyte development (0%, 15-25%, or 75-90% maximum biomass) had significant effects on nutrient assimilation of wetland community dynamics. Maximum loading of nitrate (60 g N/m2 2.4 g P/m2) applied as six weekly doses stimulated algal communities, but inhibited macrophyte communities.Predicted shifts from a stable state of macrophyte- to phytoplankton-dominance did not occur due to nutrient additions. Macrophytes, phytoplankton, and the sediment surface were all significant factors in the removal of nitrate from the Water column. Overall, these shallow macrophyte-dominated systems provided an efficient means of removing nutrients from the water column. Construction or rehabilitation of shallow, vegetated wetlands may offer promise as land management practices for nutrient removal in agricultural watersheds.
Ex-situ bioremediation of crude oil in soil, a comparative kinetic analysis.
Mohajeri, Leila; Aziz, Hamidi Abdul; Isa, Mohamed Hasnain; Zahed, Mohammad Ali; Mohajeri, Soraya
2010-07-01
Weathered crude oil (WCO) removals in shoreline sediment samples were monitored for 60 days in bioremediation experimentation. Experimental modeling was carried out using statistical design of experiments. At optimum conditions maximum of 83.13, 78.06 and 69.92% WCO removals were observed for 2, 16 and 30 g/kg initial oil concentrations, respectively. Significant variations in the crude oil degradation pattern were observed with respect to oil, nutrient and microorganism contents. Crude oil bioremediation were successfully described by a first-order kinetic model. The study indicated that the rate of hydrocarbon biodegradation increased with decrease of crude oil concentrations.
Habib, Rasikh; Asif, Muhammad Bilal; Iftekhar, Sidra; Khan, Zahiruddin; Gurung, Khum; Srivastava, Varsha; Sillanpää, Mika
2017-08-01
Relaxation and backwashing have become an integral part of membrane bioreactor (MBR) operations for fouling control. This study was carried out on real municipal wastewater to evaluate the influence of different operational strategies on membrane fouling at equivalent water yield. Four relaxation modes (MBR 10+0, MBR 10+1 , MBR 10+1.5 and MBR 10+2 ) were tested to analyze membrane fouling behavior. For the optimization of relaxation modes, fouling rate in terms of trans-membrane pressure, hydraulic resistances and characteristics of fouling fractions were analyzed. It has been observed that cake layer resistance was minimum in MBR 10+1.5 but pore blockage resistance was increased in all relaxation modes. Moreover, high instantaneous flux contributed significantly to fouling rate at the initial stage of MBR operations. Relaxation modes were also efficient in removing irreversible fouling to some extent. Under all relaxation modes, COD removal efficiency ranged from 92 to 96.5%. Ammonium and TP removal were on the lower side due to the short solids and hydraulic retention time. Copyright © 2017 Elsevier Ltd. All rights reserved.
Does mobility explain variation in colonisation and population recovery among stream fishes?
Angermeier, Paul L.; Albanese, Brett; Peterson, James T.
2009-01-01
1. Colonisation and population recovery are crucial to species persistence in environmentally variable ecosystems, but are poorly understood processes. After documenting movement rates for several species of stream fish, we predicted that this variable would influence colonisation rates more strongly than local abundance, per cent occupancy, body size and taxonomic family. We also predicted that populations of species with higher movement rates would recover more rapidly than species with lower movement rates and that assemblage structure would change accordingly. 2. To test these predictions, we removed fishes from a headwater and a mainstem creek in southwest Virginia and monitored colonisation over a 2-year period. Using an information–theoretic approach, we evaluated the relative plausibility of 15 alternative models containing different combinations of our predictor variables. Our best-supported model contained movement rate and abundance and was 41 times more likely to account for observed patterns in colonisation rates than the next-best model. Movement rate and abundance were both positively related to colonisation rates and explained 88% of the variation in colonisation rates among species. 3. Population recovery, measured as the per cent of initial abundance restored, was also positively associated with movement rate. One species recovered within 3 months, most recovered within 2 years, but two species still had not recovered after 2 years. Despite high variation in recovery, the removal had only a slight impact on assemblage structure because species that were abundant in pre-removal samples were also abundant in post-removal samples. 4. The significance of interspecific variation in colonisation and recovery rates has been underappreciated because of the widely documented recovery of stream fish assemblages following fish kills and small-scale experimental defaunations. Our results indicate that recovery of the overall assemblage does not imply recovery of each component species. Populations of species that are rare and less mobile will recover more slowly and will be more vulnerable to extinction in systems where chemical spills, hydrological alteration, extreme droughts and other impacts are frequent.
Hedegaard, Mathilde J; Albrechtsen, Hans-Jørgen
2014-01-01
Filter sand samples, taken from aerobic rapid sand filters used for treating groundwater at three Danish waterworks, were investigated for their pesticide removal potential and to assess the kinetics of the removal process. Microcosms were set up with filter sand, treated water, and the pesticides or metabolites mecoprop (MCPP), bentazone, glyphosate and p-nitrophenol were applied in initial concentrations of 0.03-2.4 μg/L. In all the investigated waterworks the concentration of pesticides in the water decreased - MCPP decreased to 42-85%, bentazone to 15-35%, glyphosate to 7-14% and p-nitrophenol 1-3% - from the initial concentration over a period of 6-13 days. Mineralisation of three out of four investigated pesticides was observed at Sjælsø waterworks Plant II - up to 43% of the initial glyphosate was mineralised within six days. At Sjælsø waterworks Plant II the removal kinetics of bentazone revealed that less than 30 min was needed to remove 50% of the bentazone at all the tested initial concentrations (0.1-2.4 μg/L). Increased oxygen availability led to greater and faster removal of bentazone in the microcosms. After 1 h, bentazone removal (an initial bentazone concentration of 0.1 μg/L) increased from 0.21%/g filter sand to 0.75%/g filter sand, when oxygen availability was increased from 0.28 mg O2/g filter sand to 1.09 mg O2/g filter sand. Bentazone was initially cleaved in the removal process. A metabolite, which contained the carbonyl group, was removed rapidly from the water phase and slowly mineralised after 24 h, while a metabolite which contained the benzene-ring was still present in the water phase. However, the microbial removal of this metabolite was initiated over seven days. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Lu; Li, Yong-feng; Wang, Yi-xuan; Yang, Chuan-ping
2010-11-01
In order to discuss the ability of H2-production and wastewater treatment, an up-flow anaerobic sludge bed (UASB) using a synthesized substrate with brown sugar wastewater was conducted to investigate the hydrogen yield, hydrogen producing rate, fermentation type of biohydrogen production, and the chemical oxygen demand (COD) removal rate, respectively. The results show that when the biomass of inoculants was 22.5 g SSṡL-1 and the influent concentration, hydraulic retention time (HRT) and initial pH were within the ranges of 4000˜6000 mg CODṡL-1, 8 h and 5-5.5, respectively, and the biohydrogen producing reactor could work effectively. The maximum hydrogen production rate is 5.98 Lṡd-1. Simultaneously, the concentration of ethanol and acetic acid is around 80% of the aqueous terminal production in the system, which presents the typical ethanol type fermentation. pH is at the range of 4˜4.5 during the whole performing process, however, the removal rate of COD is just about 20%. Therefore, it's still needs further research to successfully achieve the biohydrogen production and wastewater treatment, simultaneously.
Plasma cleaning of beamline optical components: Contamination and gas composition effects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberg, R.A.; Smith, J.A.; Wallace, D.J.
1992-01-01
We have initiated a program to study the impact of gas composition on the carbon removal rate during plasma cleaning of optical components, and of possible contamination due to the plasma processing. The measurements were performed in a test chamber designed to simulate the geometry of the grating/Codling mirror section of a Grasshopper monochromator. Removal rates were determined for a direct-current (dc) (Al electrode) discharge using a quartz crystal microbalance coated with polymethylmethacrylate, located at the position of the grating. Auger electron spectroscopy analysis of strateg- ically located, gold-coated stainless steel samples was employed to determine contamination. The relative removalmore » rates of the gases studied were 3% C{sub 2}F{sub 6}/O{sub 2}{much gt} O{sub 2}+H{sub 2}O{gt}O{sub 2}{similar to}N{sub 2}O{gt}H{sub 2}{gt}N{sub 2}. Although the C{sub 2}F{sub 6}/O{sub 2} gas mixture showed a 20 times greater removal rate than its nearest competitor, it also caused significant contamination to occur. Contamination studies were performed for both dc and radio-frequency (rf) discharges. For the dc discharge we found that great care must be taken in order to avoid Al contamination; for the rf discharge, significant Fe contamination was observed.« less
Infrastructure Requirements for an Urgent-Start Peritoneal Dialysis Program
Ghaffari, Arshia; Kumar, Vijay; Guest, Steven
2013-01-01
Patients with advanced chronic kidney disease nearing dialysis but without pre-established access almost uniformly initiate dialysis with a temporary central venous catheter. These catheters are associated with high rates of infection and flow disturbances, requiring removal and subsequent replacement. Many of these patients might be candidates for peritoneal dialysis (PD), but because of the absence of prior catheter placement, the default initial modality is hemodialysis. Recent reports, however, have demonstrated the feasibility of initiating PD urgently despite the late referral for access placement. Urgent-start PD clinical pathways require a unique infrastructure and treatment approach. This article reviews the salient features required to establish an urgent-start PD program. PMID:24335123
Creep of plasma sprayed zirconia
NASA Technical Reports Server (NTRS)
Firestone, R. F.; Logan, W. R.; Adams, J. W.
1982-01-01
Specimens of plasma-sprayed zirconia thermal barrier coatings with three different porosities and different initial particle sizes were deformed in compression at initial loads of 1000, 2000, and 3500 psi and temperatures of 1100 C, 1250 C, and 1400 C. The coatings were stabilized with lime, magnesia, and two different concentrations of yttria. Creep began as soon as the load was applied and continued at a constantly decreasing rate until the load was removed. Temperature and stabilization had a pronounced effect on creep rate. The creep rate for 20% Y2O3-80% ZrO2 was 1/3 to 1/2 that of 8% Y2O3-92% ZrO2. Both magnesia and calcia stabilized ZrO2 crept at a rate 5 to 10 times that of the 20% Y2O3 material. A near proportionality between creep rate and applied stress was observed. The rate controlling process appeared to be thermally activated, with an activation energy of approximately 100 cal/gm mole K. Creep deformation was due to cracking and particle sliding.
Veisi, Farzaneh; Zazouli, Mohammad Ali; Ebrahimzadeh, Mohammad Ali; Charati, Jamshid Yazdani; Dezfoli, Amin Shiralizadeh
2016-11-01
The photocatalytic degradation of furfural in aqueous solution was investigated using N-doped titanium dioxide nanoparticles under sunlight and ultraviolet radiation (N-TiO 2 /Sun and N-TiO 2 /UV) in a lab-scale batch photoreactor. The N-TiO 2 nanoparticles prepared using a sol-gel method were characterized using XRD, X-ray photoelectron spectroscopy (XPS), and SEM analyses. Using HPLC to monitor the furfural concentration, the effect of catalyst dosage, contact time, initial solution pH, initial furfural concentration, and sunlight or ultraviolet radiation on the degradation efficiency was studied. The efficiency of furfural removal was found to increase with increased reaction time, nanoparticle loading, and pH for both processes, whereas the efficiency decreased with increased furfural concentration. The maximum removal efficiencies for the N-TiO 2 /UV and N-TiO 2 /Sun processes were 97 and 78 %, respectively, whereas the mean removal efficiencies were 80.71 ± 2.08 % and 62.85 ± 2.41 %, respectively. In general, the degradation and elimination rate of furfural using the N-TiO 2 /UV process was higher than that using the N-TiO 2 /Sun process.
Adsorption of methyl orange from aqueous solution using chitosan/diatomite composite.
Zhao, Peng; Zhang, Runhu; Wang, Jianglin
2017-04-01
A novel chitosan/diatomite composite was prepared by a simple mixture in the mass ratio to remove methyl orange (MO) from aqueous media in this study. The composite adsorbent was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy analysis. The parameters to influence the adsorption of MO were studied under such conditions as kinetics, adsorption isotherm, pH effect, and thermodynamics. The results revealed that adsorption of MO was initially rapid and the equilibrium time was reached after 40 min. The optimal value of the pH was 5.0 for better adsorption. The equilibrium data were well fitted to the Langmuir isotherm compared to the Freundlich isotherm, and exhibited the highest capacity and a removal rate of 88.37% under an initial dye concentration of 50 mg/L. The kinetic data were well described by the pseudo-second order model. The thermodynamic calculations revealed that the sorption was viable, spontaneous, and exothermic under the conditions studied. In addition, the chitosan/diatomite composite had good adsorption and desorption performance with respect to reusability after six cycles. These results showed that the chitosan/diatomite could be considered as a potential adsorbent for the removal of MO in aqueous solution.
Effect of liquid-to-solid ratio on semi-solid Fenton process in hazardous solid waste detoxication.
Hu, Li-Fang; Feng, Hua-Jun; Long, Yu-Yang; Zheng, Yuan-Ge; Fang, Cheng-Ran; Shen, Dong-Sheng
2011-01-01
The liquid-to-solid ratio (L/S) of semi-solid Fenton process (SSFP) designated for hazardous solid waste detoxication was investigated. The removal and minimization effects of o-nitroaniline (ONA) in simulate solid waste residue (SSWR) from organic arsenic industry was evaluated by total organic carbon (TOC) and ONA removal efficiency, respectively. Initially, Box-Behnken design (BBD) and response surface methodology (RSM) were used to optimize the key factors of SSFP. Results showed that the removal rates of TOC and ONA decreased as L/S increased. Subsequently, four target initial ONA concentrations including 100 mg kg(-1), 1 g kg(-1), 10 g kg(-1), and 100 gk g(-1) on a dry basis were evaluated for the effect of L/S. A significant cubic empirical model between the initial ONA concentration and L/S was successfully developed to predict the optimal L/S for given initial ONA concentration for SSFP. Moreover, an optimized operation strategy of multi-SSFP for different cases was determined based on the residual target pollutant concentration and the corresponding environmental conditions. It showed that the total L/S of multi-SSFP in all tested scenarios was no greater than 3.8, which is lower than the conventional slurry systems (L/S ≥ 5). The multi-SSFP is environment-friendly when it used for detoxication of hazardous solid waste contaminated by ONA and provides a potential method for the detoxication of hazardous solid waste contaminated by organics. Copyright © 2010 Elsevier Ltd. All rights reserved.
de Menezes, Rebeca Ferraz; Harvey, Catherine Malinda; de Martínez Gerbi, Marleny Elizabeth Márquez; Smith, Zachary J; Smith, Dan; Ivaldi, Juan C; Phillips, Alton; Chan, James W; Wachsmann-Hogiu, Sebastian
2017-10-01
The goal of this work is to investigate the thermal effects of femtosecond laser (fs-laser) ablation for the removal of carious dental tissue. Additional studies identify different tooth tissues through femtosecond laser induced breakdown spectroscopy (fsLIBS) for the development of a feedback loop that could be utilized during ablation in a clinical setting. Scanning Election Microscope (SEM) images reveal that minimal morphological damages are incurred at repetition rates below the carbonization threshold of each tooth tissue. Thermal studies measure the temperature distribution and temperature decay during laser ablation and after laser cessation, and demonstrate that repetition rates at or below 10kHz with a laser fluence of 40 J/cm 2 would inflict minimal thermal damage on the surrounding nerve tissues and provide acceptable clinical removal rates. Spectral analysis of the different tooth tissues is also conducted and differences between the visible wavelength fsLIBS spectra are evident, though more robust classification studies are needed for clinical translation. These results have initiated a set of precautionary recommendations that would enable the clinician to utilize femtosecond laser ablation for the removal of carious lesions while ensuring that the solidity and utility of the tooth remain intact. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Biosorption of Azo dyes by spent Rhizopus arrhizus biomass
NASA Astrophysics Data System (ADS)
Salvi, Neeta A.; Chattopadhyay, S.
2017-10-01
In the present study, spent Rhizopus arrhizus biomass was used for the removal of six azo dyes from aqueous solutions. The dye removal capacity of the biomass was evaluated by conducting batch tests as a function of contact time, biomass dosage, pH and initial dye concentrations. The pseudo-second-order kinetic model fitted well with the experimental data with correlation coefficients greater than 0.999, suggesting that chemisorptions might be the rate limiting step. The equilibrium sorption data showed good fit to the Langmuir isotherm model. Among the six dyes tested, the maximum monolayer adsorption capacity for fast red A and metanil yellow was found to be 108.8 and 128.5 mg/g, respectively. These encouraging results suggest that dead Rhizopus arrhizus biomass could be a potential biomaterial for the removal of azo dyes from aqueous dye solution.
2014-01-01
Arsenic contamination of drinking water is a global problem that will likely become more apparent in future years as scientists and engineers measure the true extent of the problem. Arsenic poisoning is preventable though as there are several methods for easily removing even trace amounts of arsenic from drinking water. In the present study, electrocoagulation was evaluated as a treatment technology for arsenic removal from aqueous solutions. The effects of parameters such as initial pH, current density, initial concentration, supporting electrolyte type and stirring speed on removal efficiency were investigated. It has been observed that initial pH was highly effective on the arsenic removal efficiency. The highest removal efficiency was observed at initial pH = 4. The obtained experimental results showed that the efficiency of arsenic removal increased with increasing current density and decreased with increasing arsenic concentration in the solution. Supporting electrolyte had not significant effects on removal, adding supporting electrolyte decreased energy consumption. The effect of stirring speed on removal efficiency was investigated and the best removal efficiency was at the 150 rpm. Under the optimum conditions of initial pH 4, current density of 0.54 mA/cm2, stirring speed of 150 rpm, electrolysis time of 30 minutes, removal was obtained as 99.50%. Energy consumption in the above conditions was calculated as 0.33 kWh/m3. Electrocoagulation with iron electrodes was able to bring down 50 mg/L arsenic concentration to less than 10 μg/L at the end of electrolysis time of 45 minutes with low electrical energy consumption as 0.52 kWh/m3. PMID:24991426
Establishing Research and Management Priorities for Monoecious Hydrilla
2014-01-01
strategies. While use of high stocking rates of non-selective sterile grass carp (Ctenopharyngodon idella) has successfully controlled hydrilla in many...discussions of classical biological control agents (e.g. insects that feed specifically on hydrilla) did not yield any promising near-term candidates...possible. Diver- assisted dredging techniques and hand removal techniques were explored on the infestation in the Lake Cayuga inlet; initial results were
Dashamiri, Somayeh; Ghaedi, Mehrorang; Dashtian, Kheibar; Rahimi, Mahmood Reza; Goudarzi, Alireza; Jannesar, Ramin
2016-07-01
Copper oxide nanoparticles loaded on activated carbon (CuO-NPs-AC) were prepared and fully analyzed and characterized with FE-SEM, XRD and FT-IR. Subsequently, this novel material was used for simultaneous ultrasound-assisted adsorption of brilliant green (BG), auramine O (AO), methylene blue (MB) and eosin yellow (EY) dyes. Problems regard to dyes spectra overlap in quaternary solution of this dyes were omitted by derivative spectrophotometric method. The best pH in quaternary system was studied by using one at a time method to achieved maximum dyes removal percentage. Subsequently, sonication time, adsorbent dosage and initial dyes concentrations influence on dyes removal was optimized by central composite design (CCD) combined with desirability function approach (DFA). Desirability score of 0.978 show optimum conditions set at sonication time (4.2 min), adsorbent mass (0.029 g), initial dyes concentration (4.5 mg L(-1)). Under this optimum condition the removal percentage for MB, AO, EY and BG dyes 97.58, 94.66, 96.22 and 94.93, respectively. The adsorption rate well fitted by pseudo second-order while adsorption capacity according to the Langmuir model as best equilibrium isotherm model for BG, MB, AO and EY was 20.48, 21.26, 22.34 and 21.29 mg g(-1), respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
Ismail, Zainab Z; AbdelKareem, Hala N
2015-11-01
Sustainable management of waste materials is an attractive approach for modern societies. In this study, recycling of raw waste lamb and chicken bones for defluoridation of water has been estimated. The effects of several experimental parameters including contact time, pH, bone dose, fluoride initial concentration, bone grains size, agitation rate, and the effect of co-existing anions in actual samples of wastewater were studied for fluoride removal from aqueous solutions. Results indicated excellent fluoride removal efficiency up to 99.4% and 99.8% using lamb and chicken bones, respectively at fluoride initial concentration of 10 mg F/L and 120 min contact time. Maximum fluoride uptake was obtained at neutral pH range 6-7. Fluoride removal kinetic was well described by the pseudo-second order kinetic model. Both, Langmuir and Freundlich isotherm models could fit the experimental data well with correlation coefficient values >0.99 suggesting favorable conditions of the process. Furthermore, for complete sustainable management of waste bones, the resulted fluoride-bearing sludge was reused in concrete mixes to partially replace sand. Tests of the mechanical properties of fluoride sludge-modified concrete mixes indicated a potential environmentally friendly approach to dispose fluoride sludge in concrete and simultaneously enhance concrete properties. Copyright © 2015 Elsevier Ltd. All rights reserved.
Cai, Qinqing; Hu, Jiangyong
2017-02-05
In this study, continuous LED/UVA/TiO 2 photocatalytic decomposition of sulfamethoxazole (SMX) and trimethoprim (TMP) was investigated. More than 90% of SMX and TMP were removed within 20min by the continuous photoreactor (with the initial concentration of 400ppb for each). The removal rates of SMX and TMP decreased with higher initial antibiotics loadings. SMX was much easier decomposed in acidic condition, while pH affected little on TMP's decomposition. 0.003% was found to be the optimum H 2 O 2 dosage to enhance SMX photocatalytic decomposition. Decomposition pathways of SMX and TMP were proposed based on the intermediates identified by using LC-MS-MS and GC-MS. Aniline was identified as a new intermediate generated during SMX photocatalytic decomposition. Antibacterial activity study with a reference Escherichia coli strain was also conducted during the photocatalytic process. Results indicated that with every portion of TMP removed, the residual antibacterial activity decreased by one portion. However, the synergistic effect between SMX and TMP tended to slow down the antibacterial activity removal of SMX and TMP mixture. Chronic toxicity studies conducted with Vibrio fischeri exhibited 13-20% bioluminescence inhibition during the decomposition of 1ppm SMX and 1ppm TMP, no acute toxicity to V. fischeri was observed during the photocatalytic process. Copyright © 2016 Elsevier B.V. All rights reserved.
Lin, Hui; Wang, Yujuan; Niu, Junfeng; Yue, Zhihan; Huang, Qingguo
2015-09-01
Removal of environmentally persistent perfluoroalkyl acids (PFAAs), that is, perfluorooctanesulfonate (PFOS) and perfluorocarboxylic acids (PFCAs, C4 ∼ C10) were investigated through sorption on four metal hydroxide flocs generated in situ by electrocoagulation in deionized water with 10 mM NaCl as supporting electrolyte. The results indicated that the zinc hydroxide flocs yielded the highest removal efficiency with a wide range concentration of PFOA/PFOS (1.5 μM ∼ 0.5 mM) at the zinc dosage <150 mg L(-1) with the energy consumption <0.18 Wh L(-1). The sorption kinetics indicated that the zinc hydroxide flocs had an equilibrium adsorbed amount (qe) up to 5.74/7.69 mmol g(-1) (Zn) for PFOA/PFOS at the initial concentration of 0.5 mM with an initial sorption rate (v0) of 1.01 × 10(3)/1.81 × 10(3) mmol g(-1) h(-1). The sorption of PFOA/PFOS reached equilibrium within <10 min. The sorption mechanisms of PFAAs on the zinc hydroxide flocs were proposed based on the investigation of various driving forces. The results indicated that the hydrophobic interaction was primarily responsible for the PFAAs sorption. The electrocoagulation process with zinc anode may have a great potential for removing PFAAs from industrial wastewater as well as contaminated environmental waterbody.
[Kinetics of alkylphenols degradation in aqueous phase with excilamp irradiation].
Liu, Yu-Hai; Ye, Zhao-Lian; Wen, Ying-Pin; Bi, Cheng-Lu
2014-06-01
The 206 nm irradiation from excilamp was able to directly photo-degrade 4-nonylphenol (4-NP) and 4-octylphenol (4-OP), but it could not oxidize them completely into CO2. Under the same irradiation condition, the removal efficiency of 4-OP was higher than that of 4-NP. Pseudo-first order kinetic model and modified kinetic model were used to fit the kinetics of photo-degradation process, and the direct photolysis rate constants under 206 nm UV irradiation were obtained. The experimental results demonstrated that the photolysis rate constant was higher at lower initial concentration of alkylphenols. Two kinetic models were appropriate for the direct photolysis of alkylphenols at low concentration, but the modified model did not fit for high concentrations. Degradation rate can be obviously enhanced when adding H2O2 into the reaction, but the TOC removal was distinct only when the dosage of H2O2 was high. At last, we concluded that the direct photolysis rate constant k(d) was 0.032 8 min(-1) and the reaction rate constant k(pH) between 4-OP and H2O2 was 17.4520 L x (mol x min)(-1).
Aksel, Hacer; Serper, Ahmet
2017-01-01
The aim of this study was to compare the ability of 17% ethylenediaminetetraacetic acid (EDTA) and QMix with different concentrations and time exposures of initial sodium hypochlorite (NaOCl) to remove the smear layer from the root canals. Eighty maxillary central incisors were used. After instrumentation, the teeth were divided into eight experimental groups according to the initial and final rinse. About 2.5% and 5% NaOCl were used during instrumentation and for 1 or 3 min was used as postinstrumentation initial irrigants, and 17% EDTA and QMix used as final irrigants. The apical and middle parts of the specimens were observed by scanning electron microscope. Data were analyzed using the Kruskal-Wallis, Mann-Whitney, and Friedman's test. Regardless of the type of final irrigant, QMix allowed more smear layer removal than EDTA after using 5% initial NaOCl for 3 min. In the apical part of the root canal walls, the smear layer was not completely removed. QMix and EDTA were similarly effective in smear layer removal at the middle parts of the root canal regardless of the concentration and time exposure of initial NaOCl, while none of the irrigation protocols was able to remove smear layer at the apical parts.
Dahlan, Nuraina Anisa; Veeramachineni, Anand Kumar; Langford, Steven James; Pushpamalar, Janarthanan
2017-10-01
Crosslinked carboxymethyl cellulose grafted carboxymethyl polyvinyl alcohol (CMC-g-CMPVA) was loaded with modified magnetite iron oxide (Fe 3 O 4 ) nanoparticles to synthesise a new and easily separable adsorbent for the removal of copper (II) ions from water. The novel adsorbents were characterised by the presence of the functional group, surface morphology, crystallinity and magnetic property. The equilibrium time from the adsorption studies was found to be less than 240min for both film and bead forms while the rate of Cu 2+ removal decreased as the initial Cu 2+ concentration increased. In addition, CMC-g-CMPVA film loaded with Fe 3 O 4 /SiO 2 nanoparticles was the best adsorbent with maximum adsorption capacity of 35.34mg/g and exhibited a reusable potential. The properties exhibited by the new heterogeneous material is a promising adsorbent for the removal and recovery of copper (II) from wastewater. Copyright © 2017 Elsevier Ltd. All rights reserved.
Arsenic Removal and Its Chemistry in Batch Electrocoagulation Studies.
Sharma, Anshul; Adapureddy, Sri Malini; Goel, Sudha
2014-04-01
The aim of this study was to evaluate the impact of different oxidizing agents like light, aeration (by mixing) and electrocoagulation (EC) on the oxidation of As (III) and its subsequent removal in an EC batch reactor. Arsenic solutions prepared using distilled water and groundwater were evaluated. Optimum pH and the effect of varying initial pH on As removal efficiency were also evaluated. MaximumAs (III) removal efficiency with EC, light and aeration was 97% from distilled water and 71% from groundwater. Other results show that EC alone resulted in 90% As removal efficiency in the absence of light and mixing from distilled water and 53.6% from groundwater. Removal with light and mixing but without EC resulted in only 26% As removal from distilled water and 29% from groundwater proving that electro-oxidation and coagulation were more effective in removing arsenic compared to the other oxidizing agents examined. Initial pH was varied from 5 to 10 in distilled water and from 3 to 12 in groundwater for evaluating arsenic removal efficiency by EC. The optimum initial pH for arsenic removal was 7 for distilled water and groundwater. For all initial pHs tested between 5 and 10 in distilled water, the final pH ranged between 7 and 8 indicating that the EC process tends towards near neutral pH under the conditions examined in this study.
Kårelid, Victor; Larsson, Gen; Björlenius, Berndt
2017-05-15
Adsorption with activated carbon is widely suggested as an option for the removal of organic micropollutants including pharmaceutically active compounds (PhACs) in wastewater. In this study adsorption with granular activated carbon (GAC) and powdered activated carbon (PAC) was analyzed and compared in parallel operation at three Swedish wastewater treatment plants with the goal to achieve a 95% PhAC removal. Initially, mapping of the prevalence of over 100 substances was performed at each plant and due to low concentrations a final 22 were selected for further evaluation. These include carbamazepine, clarithromycin and diclofenac, which currently are discussed for regulation internationally. A number of commercially available activated carbon products were initially screened using effluent wastewater. Of these, a reduced set was selected based on adsorption characteristics and cost. Experiments designed with the selected carbons in pilot-scale showed that most products could indeed remove PhACs to the target level, both on total and individual basis. In a setup using internal recirculation the PAC system achieved a 95% removal applying a fresh dose of 15-20 mg/L, while carbon usage rates for the GAC application were much broader and ranged from <28 to 230 mg/L depending on the carbon product. The performance of the PAC products generally gave better results for individual PhACs in regards to carbon availability. All carbon products showed a specific adsorption for a specific PhAC meaning that knowledge of the target pollutants must be acquired before successful design of a treatment system. In spite of different configurations and operating conditions of the different wastewater treatment plants no considerable differences regarding pharmaceutical removal were observed. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Wulan, D. R.; Cahyaningsih, S.; Djaenudin
2017-03-01
In medium capacity, electroplating industry usually treats wastewater until 5 m3 per day. Heavy metal content becomes concern that should be reduced. Previous studies performed electrocoagulation method on laboratory scale, either batch or continuous. This study was aimed to compare the influence of voltage input variation into heavy metal removal in electroplating wastewater treatment using electrocoagulation process on laboratory-scale in order to determine the optimum condition for scaling up the reactor into pilot-scale. The laboratory study was performed in 1.5 L glass reactor in batch system using wastewater from electroplating industry, the voltage input varied at 20, 30 and 40 volt. The electrode consisted of aluminium 32 cm2 as sacrifice anode and copper 32 cm2 as cathode. During 120 min electrocoagulation process, the pH value was measured using pH meter, whereas the heavy metal of chromium, copper, iron, and zinc concentration were analysed using Atomic Absorption Spectrophotometer (AAS). Result showed that removal of heavy metals from wastewater increased due to the increasing of voltage input. Different initial concentration of heavy metals on wastewater, resulted the different detention time. At pilot-scale reactor with 30 V voltage input, chromium, iron, and zinc reached removal efficiency until 89-98%, when copper reached 79% efficiency. At 40V, removal efficiencies increased on same detention time, i.e. chromium, iron, and zinc reached 89-99%, whereas copper reached 85%. These removal efficiencies have complied the government standard except for copper that had higher initial concentration in wastewater. Kinetic rate also calculated in this study as the basic factor for scaling up the process.
Mohora, Emilijan; Rončević, Srdjan; Dalmacija, Božo; Agbaba, Jasmina; Watson, Malcolm; Karlović, Elvira; Dalmacija, Milena
2012-10-15
The performance of the laboratory scale electrocoagulation/flotation (ECF) reactor in removing high concentrations of natural organic matter (NOM) and arsenic from groundwater was analyzed in this study. An ECF reactor with bipolar plate aluminum electrodes was operated in the horizontal continuous flow mode. Electrochemical and flow variables were optimized to examine ECF reactor contaminants removal efficiency. The optimum conditions for the process were identified as groundwater initial pH 5, flow rate=4.3 l/h, inter electrode distance=2.8 cm, current density=5.78 mA/cm(2), A/V ratio=0.248 cm(-1). The NOM removal according to UV(254) absorbance and dissolved organic matter (DOC) reached highest values of 77% and 71% respectively, relative to the raw groundwater. Arsenic removal was 85% (6.2 μg As/l) relative to raw groundwater, satisfying the drinking water standards. The specific reactor electrical energy consumption was 17.5 kWh/kg Al. The specific aluminum electrode consumption was 66 g Al/m(3). According to the obtained results, ECF in horizontal continuous flow mode is an energy efficient process to remove NOM and arsenic from groundwater. Copyright © 2012 Elsevier B.V. All rights reserved.
High rate dry etching of InGaZnO by BCl3/O2 plasma
NASA Astrophysics Data System (ADS)
Park, Wanjae; Whang, Ki-Woong; Gwang Yoon, Young; Hwan Kim, Jeong; Rha, Sang-Ho; Seong Hwang, Cheol
2011-08-01
This paper reports the results of the high-rate dry etching of indium gallium zinc oxide (IGZO) at room temperature using BCl3/O2 plasma. We achieved an etch rate of 250 nm/min. We inferred from the x-ray photoelectron spectroscopy analysis that BOx or BOClx radicals generated from BCl3/O2 plasma cause the etching of the IGZO material. O2 initiates the etching of IGZO, and Ar removes nonvolatile byproducts from the surface during the etching process. Consequently, a smooth etched surface results when these gases are added to the etch gas.
Yang, C W; Wang, D; Tang, Q
2014-01-01
The Fenton, electro-Fenton and Fe(II)-activated peroxydisulfate (PDS) processes have been applied for the treatment of actual furfural industrial wastewater in this paper. Through the comparative study of the three processes, a suitable pretreatment technology for actual furfural wastewater treatment was obtained, and the mechanism and dynamics process of this technology is discussed. The experimental results show that Fenton technology has a good and stable effect without adjusting pH of furfural wastewater. At optimal conditions, which were 40 mmol/L H₂O₂ initial concentration and 10 mmol/L Fe²⁺ initial concentration, the chemical oxygen demand (COD) removal rate can reach 81.2% after 90 min reaction at 80 °C temperature. The PDS process also has a good performance. The COD removal rate could attain 80.3% when Na₂S₂O₈ initial concentration was 4.2 mmol/L, Fe²⁺ initial concentration was 0.1 mol/L, the temperature remained at 70 °C, and pH value remained at 2.0. The electro-Fenton process was not competent to deal with the high-temperature furfural industrial wastewater and only 10.2% COD was degraded at 80 °C temperature in the optimal conditions (2.25 mA/cm² current density, 4 mg/L Na₂SO₄, 0.3 m³/h aeration rate). For the Fenton, electro-Fenton and PDS processes in pretreatment of furfural wastewater, their kinetic processes follow the pseudo first order kinetics law. The pretreatment pathways of furfural wastewater degradation are also investigated in this study. The results show that furfural and furan formic acid in furfural wastewater were preferentially degraded by Fenton technology. Furfural can be degraded into low-toxicity or nontoxic compounds by Fenton pretreatment technology, which could make furfural wastewater harmless and even reusable.
Wang, Ziyuan; Wang, Zhixin; Pei, Yuansheng
2014-06-01
The riparian zone is an active interface for nitrogen removal, in which nitrogen transformations by microorganisms have not been valued. In this study, a three-stage system was constructed to simulate the riparian zone environments, and nitrogen removal as well as the microbial community was investigated in this 'engineered riparian system'. The results demonstrated that stage 1 of this system accounted for 41-51 % of total nitrogen removal. Initial ammonium loading and redox potential significantly impacted the nitrogen removal performances. Stages 1 and 2 were both composed of an anoxic/oxic (A/O) zone and an anaerobic column. The A/O zone removed most of the ammonium load (6.8 g/m(2)/day), while the anaerobic column showed a significant nitrate removal rate (11.1 g/m(2)/day). Molecular biological analysis demonstrated that bacterial diversity was high in the A/O zones, where ammonium-oxidizing bacteria and nitrite-oxidizing bacteria accounted for 8.42 and 3.32 % of the bacterial population, respectively. The denitrifying bacteria Acidovorax sp. and the nitrifying bacteria Nitrosospira/Nitrosomonas were the predominant microorganisms in this engineered riparian system. This three-stage system was established to achieve favorable nitrogen removal and the microbial community in the system was also retained. This investigation should deepen our understanding of biological nitrogen removal in engineered riparian zones.
NASA Astrophysics Data System (ADS)
Frisby, C. P.; Bizimis, M.; Foustoukos, D.
2013-12-01
Peridotite hosted hydrothermal vent systems are a direct link between the hydrosphere and the Earth's mantle. They promote elemental mass exchange between these two regimes, driven by hydrothermal alteration of peridotite by seawater. Most experimental, theoretical and field studies of peridotite alteration have focused on high temperature (>1800C) conditions where serpentinization is readily observed, but less is known for low-temperature alteration that likely resembles near seafloor processes. Furthermore, while major element exchange during serpentinization has been studied extensively, the behavior of trace elements remains unclear, especially at low temperatures (<1000C). Here we report data from time-series experiments designed to constrain the reaction of Sr, Ba and REE between synthetic seawater and olivine as a function of both temperature (15-900C) and mineral grain size (geometric surface area). Our experimental data shows a clear decoupling of REE from Sr-Ba under all experimental conditions. While Sr and Ba remain quantitatively in solution, the REE are being removed from the solution at rates that increase with increasing temperature and GSA (i.e. decreasing particle size). We also observe the HREE are removed from solution faster than the LREE. The REE removal can be described as a two-stage process, with a fast initial rate followed by a slower rate as the reaction approaches equilibrium. For instance at 900C and GSA of 57.57cm2/g (average grain diameter of 258.7μm), 50% of Nd is removed in 8 hours but only 80% at 120 hours. We quantify the initial reaction rate constant of each element as a function of temperature and grain size, in order to understand the mechanisms of REE removal. The experimentally determined surface-normalized reaction rate constants (0.29-1.84 s-1m-2), constrain the temperature dependence and activation energy for the scavenging of REE driven by olivine hydrolysis. For example, LREE reaction rates have a higher temperature dependency than the HREE, i.e. higher activation energy for Nd than Yb. This activation energy does not correlate well with ionic radius, but correlates well with the third ionization potential of REE. This indicates a 3+ charge speciation for the REE upon removal to the olivine substrate. Recent experimental data had shown the formation of secondary phases (i.e. Fe(III)-(hydr)oxides, Fe bearing-talc and Fe(II)-brucite) with olivine, facilitated by the presence of spinel [1], that may contribute to the REE scavenging observed here. Our experiments however are pure olivine (>99.9%) and spinel-free. We also observed limited dissolution (<0.001%) of olivine at up to 21 days of reaction, and no evidence for the formation of Fe-oxyhydroxides, using ICPMS, XRD, Mossbauer and SEM methods. It therefore seems unlikely that Fe(III)-(hydr)oxides are responsible for the REE fractionations. This new information will enhance our limited understanding of the cycling of REE in seawater hydrothermal circulation and abyssal peridotite alteration. 1. Mayhew et al (2013) Nat Geo. 6, 478-484
Miran, Waheed; Jang, Jiseon; Nawaz, Mohsin; Shahzad, Asif; Lee, Dae Sung
2018-06-15
Microbial fuel cells (MFCs) are known for their ability to enhance the removal rate of toxins while generating power. This research presents a performance assessment of MFCs for power generation and sulfamethoxazole (SMX) degradation using SMX acclimatized cultures. Experiments were performed in MFC batch mode using different SMX concentrations in synthetic wastewater. The experimental results showed that voltage generation was >400mV up to the SMX concentration of 0.20mM (at 400Ω external resistance). Control experiments supported the inference that biodegradation was the main process for SMX removal compared to sorption by SMX acclimatized cultures and that the process results in efficient removal of SMX in MFC mode. The specific removal rates of SMX in MFC with SMX acclimatized sludge were 0.67, 1.37, 3.43, 7.32, and 13.36μm/h at initial SMX concentrations of 0.04, 0.08, 0.20, 0.39, and 0.79mM, respectively. Moreover, the MFC was able to remove >90% of the TOC from the wastewater up to SMX concentrations of 0.08mM. However, this TOC removal produces negative effects at higher SMX concentrations due to toxic intermediates. Microbial community analysis revealed large changes in bacterial communities at the phylum, class, and genus levels after SMX acclimatization and MFC operation. Thauera, a well-known aromatic-degrading bacteria, was the most dominant genus present in post-acclimatized conditions. In summary, this study showed that acclimatized sludge can play an important role in the biodegradation of SMX in MFCs. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhang, Xiaomeng; Inoue, Takashi; Kato, Kunihiko; Izumoto, Hayato; Harada, June; Wu, Da; Sakuragi, Hiroaki; Ietsugu, Hidehiro; Sugawara, Yasuhide
2017-01-01
This study followed three field-scale hybrid subsurface flow constructed wetland (CW) systems constructed in Hokkaido, northern Japan: piggery O (2009), dairy G (2011), and dairy S (2006). Treatment performance was monitored from the outset of operation for each CW. The ranges of overall purification efficiency for these systems were 70-86%, 40-85%, 71-90%, 91-96%, 94-98%, 84-97%, and 70-97% for total N (TN), NH 4 -N, total P, chemical oxygen demand (COD), biochemical oxygen demand, suspended solid, and total Coliform, respectively. The hybrid system's removal rates were highest when influent loads were high. COD removal rates were 46.4 ± 49.2, 94.1 ± 36.6, and 25.1 ± 15.5 g COD m -2 d -1 in piggery O, dairy G, and dairy S, with average influent loads of 50.5 ± 51.5, 98.9 ± 37.1, and 26.9 ± 16.0 g COD m -2 d -1 , respectively. The systems had overall COD removal efficiencies of around 90%. TN removal efficiencies were 62 ± 19%, 82 ± 9%, and 82 ± 15% in piggery O, dairy G, and dairy S, respectively. NH 4 -N removal efficiency was adversely affected by the COD/TN ratio. Results from this study prove that these treatment systems have sustained and positive pollutant removal efficiencies, which were achieved even under extremely cold climate conditions and many years after initial construction.
Lv, Xiaoshu; Xu, Jiang; Jiang, Guangming; Tang, Jie; Xu, Xinhua
2012-03-01
For the first time, nanoscale zero-valent iron (nZVI)-Fe(3)O(4) nanocomposites, prepared by an in situ reduction method, are employed for chromium(VI) removal in aqueous environment. 96.4% Cr(VI) could be removed by these novel materials within 2h under pH of 8.0 and initial Cr concentration of 20 mg L(-1), compared with 48.8% by bare nFe(3)O(4) and 18.8% by bare nZVI. Effects of several factors, including mass composition of nZVI-Fe(3)O(4) nanocomposites, initial pH and Cr(VI) concentration, were evaluated. The optimal ratio of nFe(3)O(4) to nZVI mass lies at 12:1 with a fixed nZVI concentration of 0.05 g L(-1). Low pH and initial Cr(VI) concentration could increase both the Cr(VI) removal efficiency and reaction rate. Corresponding reaction kinetics fitted well with the pseudo second-order adsorption model. Free energy change (ΔG) of this reaction was calculated to be -4.6 kJ mol(-1) by thermodynamic study, which confirmed its spontaneous and endothermic characteristic. The experimental data could be well described by the Langmuir and Freundlich model, and the maximum capacity (q(max)) obtained from the Langmuir model was 100 and 29.43 mg g(-1) at pH 3.0 and 8.0, respectively. The reaction mechanism was discussed in terms of the mutual benefit brought by the electron transfer from Fe(0) to Fe(3)O(4). Copyright © 2011 Elsevier Inc. All rights reserved.
Adsorptive removal of Auramine-O: kinetic and equilibrium study.
Mall, Indra Deo; Srivastava, Vimal Chandra; Agarwal, Nitin Kumar
2007-05-08
Present study deals with the adsorption of Auramine-O (AO) dye by bagasse fly ash (BFA) and activated carbon-commercial grade (ACC) and laboratory grade (ACL). BFA is a solid waste obtained from the particulate collection equipment attached to the flue gas line of the bagasse fired boilers of cane sugar mills. Batch studies were performed to evaluate the influences of various experimental parameters like initial pH (pH(0)), contact time, adsorbent dose and initial concentration (C(0)) for the removal of AO. Optimum conditions for AO removal were found to be pH(0) approximately 7.0 and equilibrium time approximately 30 min for BFA and approximately 120 min for activated carbons. Optimum BFA, ACC and ACL dosages were found to be 1, 20 and 2g/l, respectively. Adsorption of AO followed pseudo-second order kinetics with the initial sorption rate for adsorption on BFA being the highest followed by those on ACL and ACC. The sorption process was found to be controlled by both film and pore diffusion with film diffusion at the earlier stages followed by pore diffusion at the later stages. Equilibrium isotherms for the adsorption of AO on BFA, ACC and ACL were analyzed by Freundlich, Langmuir, Dubinin-Radushkevich, and Temkin isotherm equations using linear correlation coefficient. Langmuir isotherm gave the best correlation of adsorption for all the adsorbents studied. Thermodynamic study showed that adsorption of AO on ACC (with a more negative Gibbs free energy value) is more favoured. BFA which was used without any pretreatment showed high surface area, pore volume and pore size exhibiting its potential to be used as an adsorbent for the removal of AO.
Kinetic degradation of guar gum in oilfield wastewater by photo-Fenton process.
Wang, Shunwu; Li, Ziwang; Yu, Qinglong
2017-01-01
Guar gum is considered as a main component of oilfield wastewater. This work is intended to optimize the experimental conditions (H 2 O 2 dosage, Fe 2+ dosage, initial concentration of organics, initial pH and temperature) for the maximum oxidative degradation of guar gum by Fenton's reagent. The kinetics of guar gum removal were evaluated by means of the chemical oxygen demand (COD) and the absorbance measurements. The batch experiment results showed that the optimum conditions were: H 2 O 2 dosage, 10,000 mg/L; Fe 2+ dosage, 2,000 mg/L; initial concentration of organics, 413 mg/L; pH, 3 and temperature, 35 °C, under which the COD removal could reach 61.07% and fairly good stability could be obtained. Under the optimum experimental conditions, using UV irradiation to treat the wastewater, the photo-Fenton systems can successfully eliminate COD from guar gum solution. The COD removal always obeyed a pseudo-first-order kinetics and the degradation rate (k app ) was increased by 25.7% in the photo-Fenton process compared to the Fenton process. The photo-Fenton system needed less time and consequently less quantity of H 2 O 2 to obtain the same results as the Fenton process. The photo-Fenton process needs a dose of H 2 O 2 20.46% lower than that used in the Fenton process to remove 79.54% of COD. The cost of the photo/Fenton process amounted to RMB9.43/m 3 , which was lower than that of the classic Fenton process alone (RMB10.58/m 3 ) and the overall water quality of the final effluent could meet the class Ι national wastewater discharge standard for the petrochemical industry of China.
NASA Astrophysics Data System (ADS)
Fried, Daniel; Ragadio, Jerome N.; Akrivou, Maria; Featherstone, John D.; Murray, Michael W.; Dickenson, Kevin M.
2001-04-01
Pulsed CO2 lasers have been shown to be effective for both removal and modification of dental hard tissue for the treatment of dental caries. In this study, sealed transverse excited atmospheric pressure (TEA) laser systems optimally tuned to the highly absorbed 9.6 micrometers wavelength were investigated for application on dental hard tissue. Conventional TEA lasers produce an initial high energy spike at the beginning of the laser pulse of submicrosecond duration followed by a long tail of about 1 - 4 microsecond(s) . The pulse duration is well matched to the 1 - 2 microsecond(s) thermal relaxation time of the deposited laser energy at 9.6 micrometers and effectively heats the enamel to the temperatures required for surface modification at absorbed fluences of less than 0.5 J/cm2. Thus, the heat deposition in the tooth and the corresponding risk of pulpal necrosis from excessive heat accumulation is minimized. At higher fluences, the high peak power of the laser pulse rapidly initiates a plasma that markedly reduces the ablation rate and efficiency, severely limiting applicability for hard tissue ablation. By lengthening the laser pulse to reduce the energy distributed in the initial high energy spike, the plasma threshold can be raised sufficiently to increase the ablation rate by an order of magnitude. This results in a practical and efficient CO2 laser system for caries ablation and surface modification.
NASA Astrophysics Data System (ADS)
Rooper, Christopher N.; Wilkins, Mark E.; Rose, Craig S.; Coon, Catherine
2011-11-01
The abundance of some marine fish species are correlated to the abundance of habitat-forming benthic organisms such as sponges and corals. A concern for fisheries management agencies is the recovery of these benthic invertebrates from removal or mortality from bottom trawling and other commercial fisheries activities. Using a logistic model, observations of available substrate and data from bottom trawl surveys of the Aleutian Islands, Alaska, we estimated recovery rates of sponges and corals following removal. The model predicted the observed sponge and coral catch in bottom trawl surveys relatively accurately ( R2=0.38 and 0.46). For sponges, the results show that intrinsic growth rates were slow ( r=0.107 yr -1). Results show that intrinsic growth rates of corals were also slow ( r=0.062 yr -1). The best models for corals and sponges were models that did not include the impacts of commercial fishing removals. Subsequent recovery times for both taxa were also predicted to be slow. Mortality of 67% of the initial sponge biomass would recover to 80% of the original biomass after 20 years, while mortality of 67% of the coral biomass would recover to 80% of the original biomass after 34 years. The modeled recovery times were consistent with previous studies in estimating that recovery times were of the order of decades, however improved data from directed studies would no doubt improve parameter estimates and reduce the uncertainty in the model results. Given their role as a major ecosystem component and potential habitat for marine fish, damage and removal of sponges and corals must be considered when estimating the impacts of commercial bottom trawling on the seafloor.
Urtiaga, Ane; Soriano, Alvaro; Carrillo-Abad, Jordi
2018-06-01
The concerns about the undesired impacts on human health and the environment of long chain perfluorinated alkyl substances (PFASs) have driven industrial initiatives to replace PFASs by shorter chain fluorinated homologues. 6:2 fluorotelomer sulfonic acid (6:2 FTSA) is applied as alternative to PFOS in metal plating and fluoropolymer manufacture. This study reports the electrochemical treatment of aqueous 6:2 FTSA solutions on microcrystalline BDD anodes. Bench scale batch experiments were performed, focused on assessing the effect of the electrolyte and the applied current density (5-600 A m -2 ) on the removal of 6:2 FTSA, the reduction of total organic carbon (TOC) and the fluoride release. Results showed that at the low range of applied current density (J = 50 A m -2 ), using NaCl, Na 2 SO 4 and NaClO 4 , the electrolyte exerted a minimal effect on removal rates. The formation of toxic inorganic chlorine species such as ClO 4 - was not observed. When using Na 2 SO 4 electrolyte, increasing the applied current density to 350-600 A m -2 promoted a notable enhancement of the 6:2 FTSA removal and defluorination rates, pointing to the positive contribution of electrogenerated secondary oxidants to the overall removal rate. 6:2 FTSA was transformed into shorter-chain PFCAs, and eventually into CO 2 and fluoride, as TOC reduction was >90%. Finally, it was demonstrated that diffusion in the liquid phase was controlling the overall kinetic rate, although with moderate improvements due to secondary oxidants at very high current densities. Copyright © 2018 Elsevier Ltd. All rights reserved.
Use of hollow fiber membrane filtration for the removal of DMSO from platelet concentrates.
Arnaud, F; Kapnik, E; Meryman, H T
2003-05-01
It has been hypothesized that, in addition to freezing injury, some damage to platelets may result from the cell packing that occurs during removal of the cryoprotectant. This study examined DMSO removal by fluid exchange across hollow-fiber (HF) filters as an alternative to centrifugation. The DMSO solution with or without cell suspension was passed once through the filter. The optimum exchange during unloading of DMSO was determined by varying the flow rates in the external and internal compartments of the HF filter. Initially, buffered solutions of a 5% DMSO solution in the absence of platelets were pumped into the fibers and exchanged against PBS. The residual DMSO was determined by osmometry. The exchange of DMSO across the membrane was flow dependent and also influenced by the chemical nature of the HF fibers. No protocol using a reasonable rate flow through the fibers removed more than 95% of the DMSO in a single pass. The optimum protocol was achieved with polysynthane fibers with an internal flow rate of approximately 20 mi/min and an external flow rate of 100 ml/min. Subsequently, frozen/thawed platelet concentrates in DMSO were washed using centrifugation and compared to the HF filtration method. Platelet quality was assayed by flow cytometry, cell count, morphology and osmotic stress test. Both filtration and centrifugal washing techniques resulted in comparable morphological scores and numbers of discoid cells. When agents reducing platelet activation were added, platelet quality was improved after washing by either technique. The lower platelet osmotic response with HF filtration than with centrifugation while using activation inhibitors was attributed to the remaining amount of the inhibitors. All other parameters tested were similar. The expression of CD62P was equivalent with both techniques, and centrifugation did not activate platelets more than filtration contrary to what was originally anticipated. In conclusion, platelet quality was comparable after washing by either technique but hollow fiber filtration does remove cryoprotectant more rapidly than does centrifugation.
Tang, Jie; Chen, Chunxia; Chen, Lei; Daroch, Maurycy; Cui, Yan
2017-10-01
Various geographical duckweed isolates have been developed for phytoremediation of lead. The Pb 2+ removal efficiency of Lemna aequinoctialis, Landoltia punctata, and Spirodela polyrhiza was investigated in monoculture and polyculture at different levels of pH and initial Pb 2+ concentrations. L. aequinoctialis was not sensitive to the tested pH but significantly affected by initial Pb 2+ concentration, whereas synergistic effect of pH and initial Pb 2+ concentration on removal efficiency of L. punctata and S. polyrhiza was found. Although the majority of polycultures showed median removal efficiency as compared to respective monocultures, some of the polycultures achieved higher Pb 2+ removal efficiencies and can promote population to remove Pb 2+ . Besides, the three duckweed strains could be potential candidates for Pb 2+ remediation as compared to previous reports. Conclusively, this study provides useful references for future large-scale duckweed phytoremediation.
Cadmium removal from wastewater by sponge iron sphere prepared by hydrogen reduction.
Li, Junguo; Wei, Linghong; Li, Yungang; Bi, Na; Song, Fangfang
2011-06-01
A new type of sponge iron sphere (NSIS) with 1-5 mm diameter, made of concentrated iron powder and possessed high activity and intension, was prepared by mini-pellet sintering integrated with H2 direct reduction. Static state experiment has been carried on to investigate the Cd(2+) removal efficiency from wastewater by the NSIS and to explore the Cd(2+) removal reaction kinetics. It was suggested that initial pH value and Cd(2+) original concentration had significant influence on Cd(2+) removal percentage. Cd(2+) removal percentage decreased significantly with the increasing of Cd(2+)original concentration whether the original pH value be adjusted to 3.0 or without adjustment. The results showed that the Cd(2+) removal process followed the first order reaction because the reaction order was from 0.803 to 0.996. The apparent reaction rate constant between Cd(2+) and NSIS was from 0.0025 to 0.1000 (mg·L(-1))(1-n)·min(-1). Compared with SIS reduced by charcoal reduction, NSIS deoxided by hydrogen possessed higher activity, and could remove the same quantity of Cd(2+) within a shorter period of time. Copyright © 2011 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.
Ruiz, J; Arbib, Z; Alvarez-Díaz, P D; Garrido-Pérez, C; Barragán, J; Perales, J A
2014-05-20
This work was aimed at studying the effect of light-darkness and high-low biomass concentrations in the feasibility of removing nitrogen and phosphorus from urban treated wastewater by the microalga Scenedesmus obliquus. Laboratory experiments were conducted in batch, where microalgae were cultured under different initial biomass concentrations (150 and 1500mgSSl(-1)) and light conditions (dark or illuminated). Nutrient uptake was more dependent on internal nutrient content of the biomass than on light presence or biomass concentration. When a maximum nitrogen or phosphorus content in the biomass was reached (around 8% and 2%, respectively), the removal of that nutrient was almost stopped. Biomass concentration affected more than light presence on the nutrient removal rate, increasing significantly with its increase. Light was only required to remove nutrients when the maximum nutrient storage capacity of the cells was reached and further growth was therefore needed. Residence times to maintain a stable biomass concentration, avoiding the washout of the reactor, were much higher than those needed to remove the nutrients from the wastewater. This ability to remove nutrients in the absence of light could lead to new configurations of reactors aimed to wastewater treatment. Copyright © 2014 Elsevier B.V. All rights reserved.
Controlling the Growth of Future LEO Debris Populations with Active Debris Removal
NASA Technical Reports Server (NTRS)
Liou, J.-C.; Johnson, N. L.; Hill, N. M.
2008-01-01
Active debris removal (ADR) was suggested as a potential means to remediate the low Earth orbit (LEO) debris environment as early as the 1980s. The reasons ADR has not become practical are due to its technical difficulties and the high cost associated with the approach. However, as the LEO debris populations continue to increase, ADR may be the only option to preserve the near-Earth environment for future generations. An initial study was completed in 2007 to demonstrate that a simple ADR target selection criterion could be developed to reduce the future debris population growth. The present paper summarizes a comprehensive study based on more realistic simulation scenarios, including fragments generated from the 2007 Fengyun-1C event, mitigation measures, and other target selection options. The simulations were based on the NASA long-term orbital debris projection model, LEGEND. A scenario, where at the end of mission lifetimes, spacecraft and upper stages were moved to 25-year decay orbits, was adopted as the baseline environment for comparison. Different annual removal rates and different ADR target selection criteria were tested, and the resulting 200-year future environment projections were compared with the baseline scenario. Results of this parametric study indicate that (1) an effective removal strategy can be developed based on the mass and collision probability of each object as the selection criterion, and (2) the LEO environment can be stabilized in the next 200 years with an ADR removal rate of five objects per year.
A comparative study of HO•- and SO4•--based AOPs for the degradation of non-ionic surfactant Brij30.
Kabdaşlı, Işık; Ecer, Çisem; Olmez-Hanci, Tugba; Tünay, Olcay
2015-01-01
In the present study aqueous solutions of Brij30, an alcohol ethoxylate surfactant, were photocatalytically and photochemically treated by employing the TiO2/UV-A, H2O2/UV-C and persulfate (PS)/UV-C processes. During TiO2/UV-A treatment, even in short reaction periods (10 minutes), high rates of Brij30 removals were achieved; however, longer experiment periods (240-480 minutes) were needed in order to obtain notable total organic carbon (TOC) removals. Increasing the TiO2 dosage exhibited a positive effect on treatment efficiencies. For initial pH value of 3.0, increasing the TiO2 dosage from 1.0 to 1.5 g/L resulted in an improvement in Brij30 removal from 64% to 79% after 10 minutes whereas 68 and 88% TOC removals were observed after 480 minutes, respectively. Brij30 removal was very fast and complete via both H2O2/UV-C and PS/UV-C treatments, accompanied with significant mineralization rates ranging between 74 and 80%. Toxicity assessed by Vibrio fischeri, was found to be similar to that of the original Brij30 solution during H2O2/UV-C treatment, while in the PS/UV-C process, the relative inhibition of Brij30 towards V. fischeri fluctuated throughout the treatment and eventually non-toxic products were formed by the oxidation of SO4•- radicals.
Colina-Márquez, José; Machuca-Martínez, Fiderman; Li Puma, Gianluca
2015-07-22
Endocrine disruptors in water are contaminants of emerging concern due to the potential risks they pose to the environment and to the aquatic ecosystems. In this study, a solar photocatalytic treatment process in a pilot-scale compound parabolic collector (CPC) was used to remove commercial estradiol formulations (17-β estradiol and nomegestrol acetate) from water. Photolysis alone degraded up to 50% of estradiol and removed 11% of the total organic carbon (TOC). In contrast, solar photocatalysis degraded up to 57% of estrogens and the TOC removal was 31%, with 0.6 g/L of catalyst load (TiO2 Aeroxide P-25) and 213.6 ppm of TOC as initial concentration of the commercial estradiols formulation. The adsorption of estrogens over the catalyst was insignificant and was modeled by the Langmuir isotherm. The TOC removal via photocatalysis in the photoreactor was modeled considering the reactor fluid-dynamics, the radiation field, the estrogens mass balance, and a modified Langmuir-Hinshelwood rate law, that was expressed in terms of the rate of photon adsorption. The optimum removal of the estrogens and TOC was achieved at a catalyst concentration of 0.4 g/L in 29 mm diameter tubular CPC reactors which approached the optimum catalyst concentration and optical thickness determined from the modeling of the absorption of solar radiation in the CPC, by the six-flux absorption-scattering model (SFM).
Total morphine stability in urine specimens stored under various conditions.
Chang, B L; Huang, M K; Tsai, Y Y
2000-09-01
The stability of total morphine in urine stored under various conditions was studied using control and experimental specimens. Samples in the control group were prepared using drug-free urine spiked with morphine at three concentration levels (300, 1000, and 2500 ng/mL), each with the pH adjusted to 5.5, 6.5, and 7.5. Samples in the experimental group came from 20 alleged heroin addicts (provided by Taipei Municipal Psychiatric Hospital). Samples in both groups were divided into two categories--one with and one without the precipitate (formed at 0 degrees C) removed. Samples in each of these two categories were further divided into two sub-groups--one with and one without sodium azide (0.05%) added. Total morphine contents in these samples were first determined by gas chromatography-mass spectrometry prior to storage and at 6, 12, 18, and 24 months following storage at -20, 4, 25, and 35 degrees C. Effects of sample treatment (azide addition and precipitate removal), pH, and storage temperature and length were evaluated by examining the percentage of total morphine remaining at the four time intervals following the initial determination. Major findings were as follows: (1) total morphine decomposition was minimal when stored for 12 months at -20 degrees C, which is a common current practice; (2) samples with lower initial sample pH had slower total morphine decomposition rates; and (3) azide addition appeared to have no detectable effect, whereas precipitate removal appeared to marginally reduce the decomposition rate, especially for samples with lower pH.
NASA Astrophysics Data System (ADS)
McIntire, C.; Vadeboncoeur, M. A.; Coble, A.; Jennings, K.; Asbjornsen, H.
2016-12-01
Climate change is likely to affect the Northern Forest region through the increased frequency and severity of drought events. However, our understanding of how the Northern Forest, which is adapted to humid temperate conditions, will respond to moderate to extreme droughts is limited. Given the important role that these forests play in protecting ecosystem services and in supplying forest products, enhancing our knowledge about impacts of drought is critical to ensuring effective forest management and adaptation to climate change. The Northern Forest DroughtNet project aims to simulate a four-year severe drought by removing 55% of the incoming throughfall; thus representing the 99th percentile of annual precipitation based on historic precipitation data in Durham, NH. This is accomplished using two replicated 900 m2 throughfall removal structures consisting of a network of gutters that capture and divert incoming precipitation away from the established treatment area. Data presented here will address the ecosystem response to the drought treatment over the course of the first year of the experiment as well as validate the effectiveness and artifacts of the throughfall removal structure. Response variables of interest include soil moisture content, above and below ground biomass production, litterfall, decomposition rates, leaf water potential, foliar gas exchange, and whole tree transpiration rates. Preliminary findings provide insight into the effectiveness of using throughfall manipulation experiments in a temperate forest ecosystem to simulate an extreme drought event, as well as initial tree physiological and growth responses in relation to soil moisture availability and the implications for future climate change impacts.
Fluid dynamics analysis of a gas attenuator for X-ray FELs under high-repetition-rate operation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Bo; Wu, Juhao; Raubenheimer, Tor O.
Newtonian fluid dynamics simulations were performed using the Navier–Stokes–Fourier formulations to elucidate the short time-scale (µs and longer) evolution of the density and temperature distributions in an argon-gas-filled attenuator for an X-ray free-electron laser under high-repetition-rate operation. Both hydrodynamic motions of the gas molecules and thermal conductions were included in a finite-volume calculation. It was found that the hydrodynamic wave motions play the primary role in creating a density depression (also known as a filament) by advectively transporting gas particles away from the X-ray laser–gas interaction region, where large pressure and temperature gradients have been built upon the initial energymore » depositionviaX-ray photoelectric absorption and subsequent thermalization. Concurrent outward heat conduction tends to reduce the pressure in the filament core region, generating a counter gas flow to backfill the filament, but on an initially slower time scale. If the inter-pulse separation is sufficiently short so the filament cannot recover, the depth of the filament progressively increases as the trailing pulses remove additional gas particles. Since the rate of hydrodynamic removal decreases while the rate of heat conduction back flow increases as time elapses, the two competing mechanisms ultimately reach a dynamic balance, establishing a repeating pattern for each pulse cycle. Finally, by performing simulations at higher repetition rates but lower per pulse energies while maintaining a constant time-averaged power, the amplitude of the hydrodynamic motion per pulse becomes smaller, and the evolution of the temperature and density distributions approach asymptotically towards, as expected, those calculated for a continuous-wave input of the equivalent power.« less
Fluid dynamics analysis of a gas attenuator for X-ray FELs under high-repetition-rate operation
Yang, Bo; Wu, Juhao; Raubenheimer, Tor O.; ...
2017-05-01
Newtonian fluid dynamics simulations were performed using the Navier–Stokes–Fourier formulations to elucidate the short time-scale (µs and longer) evolution of the density and temperature distributions in an argon-gas-filled attenuator for an X-ray free-electron laser under high-repetition-rate operation. Both hydrodynamic motions of the gas molecules and thermal conductions were included in a finite-volume calculation. It was found that the hydrodynamic wave motions play the primary role in creating a density depression (also known as a filament) by advectively transporting gas particles away from the X-ray laser–gas interaction region, where large pressure and temperature gradients have been built upon the initial energymore » depositionviaX-ray photoelectric absorption and subsequent thermalization. Concurrent outward heat conduction tends to reduce the pressure in the filament core region, generating a counter gas flow to backfill the filament, but on an initially slower time scale. If the inter-pulse separation is sufficiently short so the filament cannot recover, the depth of the filament progressively increases as the trailing pulses remove additional gas particles. Since the rate of hydrodynamic removal decreases while the rate of heat conduction back flow increases as time elapses, the two competing mechanisms ultimately reach a dynamic balance, establishing a repeating pattern for each pulse cycle. Finally, by performing simulations at higher repetition rates but lower per pulse energies while maintaining a constant time-averaged power, the amplitude of the hydrodynamic motion per pulse becomes smaller, and the evolution of the temperature and density distributions approach asymptotically towards, as expected, those calculated for a continuous-wave input of the equivalent power.« less
NASA Astrophysics Data System (ADS)
Rout, Bapin Kumar; Brooks, Geoffrey; Akbar Rhamdhani, M.; Li, Zushu; Schrama, Frank N. H.; Overbosch, Aart
2018-06-01
In a previous study by the authors (Rout et al. in Metall Mater Trans B 49:537-557, 2018), a dynamic model for the BOF, employing the concept of multizone kinetics was developed. In the current study, the kinetics of decarburization reaction is investigated. The jet impact and slag-metal emulsion zones were identified to be primary zones for carbon oxidation. The dynamic parameters in the rate equation of decarburization such as residence time of metal drops in the emulsion, interfacial area evolution, initial size, and the effects of surface-active oxides have been included in the kinetic rate equation of the metal droplet. A modified mass-transfer coefficient based on the ideal Langmuir adsorption equilibrium has been proposed to take into account the surface blockage effects of SiO2 and P2O5 in slag on the decarburization kinetics of a metal droplet in the emulsion. Further, a size distribution function has been included in the rate equation to evaluate the effect of droplet size on reaction kinetics. The mathematical simulation indicates that decarburization of the droplet in the emulsion is a strong function of the initial size and residence time. A modified droplet generation rate proposed previously by the authors has been used to estimate the total decarburization rate by slag-metal emulsion. The model's prediction shows that about 76 pct of total carbon is removed by reactions in the emulsion, and the remaining is removed by reactions at the jet impact zone. The predicted bath carbon by the model has been found to be in good agreement with the industrially measured data.
NASA Astrophysics Data System (ADS)
Rout, Bapin Kumar; Brooks, Geoffrey; Akbar Rhamdhani, M.; Li, Zushu; Schrama, Frank N. H.; Overbosch, Aart
2018-03-01
In a previous study by the authors (Rout et al. in Metall Mater Trans B 49:537-557, 2018), a dynamic model for the BOF, employing the concept of multizone kinetics was developed. In the current study, the kinetics of decarburization reaction is investigated. The jet impact and slag-metal emulsion zones were identified to be primary zones for carbon oxidation. The dynamic parameters in the rate equation of decarburization such as residence time of metal drops in the emulsion, interfacial area evolution, initial size, and the effects of surface-active oxides have been included in the kinetic rate equation of the metal droplet. A modified mass-transfer coefficient based on the ideal Langmuir adsorption equilibrium has been proposed to take into account the surface blockage effects of SiO2 and P2O5 in slag on the decarburization kinetics of a metal droplet in the emulsion. Further, a size distribution function has been included in the rate equation to evaluate the effect of droplet size on reaction kinetics. The mathematical simulation indicates that decarburization of the droplet in the emulsion is a strong function of the initial size and residence time. A modified droplet generation rate proposed previously by the authors has been used to estimate the total decarburization rate by slag-metal emulsion. The model's prediction shows that about 76 pct of total carbon is removed by reactions in the emulsion, and the remaining is removed by reactions at the jet impact zone. The predicted bath carbon by the model has been found to be in good agreement with the industrially measured data.
NASA Astrophysics Data System (ADS)
Rad, Leila Roshanfekr; Haririan, Ismaeil; Divsar, Faten
2015-02-01
In the present study, adsorption and photo-Fenton processes have been compared for the removal of phenol and paracetamol from aqueous solutions in a single and binary systems. NaX nanozeolites and cobalt ferrite nanoparticles were used during adsorption and photo-Fenton processes, respectively. Both nanoparticles were synthesized using microwave heating method. The synthesized nanoparticles were characterized using powder X-ray diffraction (XRD) and scanning electronic microscopy (SEM) analysis. Based on results, more than 99% removing percentages of phenol and paracetamol were obtained during photo-Fenton process at initial concentrations of 10, 20, 50, 100 and 200 mg/L of phenol and paracetamol. Moreover, the complete removing of phenol and paracetamol was only achieved at lower initial concentrations than 10 mg/L for phenol and paracetamol during adsorption process. The results showed a significant dependence of the phenol and paracetamol removing on the initial concentrations of phenol and paracetamol for selection of process. The photo-Fenton process could be considered an alternative method in higher initial concentrations of phenol and paracetamol. However, the adsorption process due to economical issue was preferred for phenol and paracetamol removing at lower initial concentrations. The kinetic data of photo-Fenton and adsorption processes were well described using first-order and pseudo-second-order kinetic models. The results of phenol and paracetamol removing in a binary system confirmed the obtained results of single removing of phenol and paracetamol in selection of process.
Zhang, Qinghua; Zhang, Lei; Wang, Han; Jiang, Qinrui; Zhu, Xiaoyu
2018-02-01
The performance of a microbial fuel cell (MFC) to degrade oxyfluorfen was investigated. Approximately 77% of 50 mg/L oxyfluorfen was degraded within 24 h by anodic biofilm. The temperature, pH, and initial oxyfluorfen concentration had a significant effect on oxyfluorfen degrading, and a maximum degradation rate of 94.95% could theoretically be achieved at 31.96 °C, a pH of 7.65, and an initial oxyfluorfen concentration of 120.05 mg/L. Oxyfluorfen was further catabolized through various microbial metabolism pathways. Moreover, the anodic biofilm exhibited multiple catabolic capacities to 4-nitrophenol, chloramphenicol, pyraclostrobin, and sulfamethoxazole. Microbial community analysis indicated that functional bacteria Arcobacter, Acinetobacter, Azospirillum, Azonexus, and Comamonas were the predominant genera in the anodic biofilm. In terms of the efficient removal of various organic compounds and energy recovery, the MFC seemed to be a promising approach for the treatment of environmental contaminants. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Albroomi, H. I.; Elsayed, M. A.; Baraka, A.; Abdelmaged, M. A.
2017-07-01
This work describes the potential of utilizing prepared activated carbon from apricot stones as an efficient adsorbent material for tartrazine (TZ) azo-dye removal in a batch and dynamic adsorption system. The results revealed that activated carbons with well-developed surface area (774 m2/g) and pore volume (1.26 cm3/g) can be manufactured from apricot stones by H3PO4 activation. In batch experiments, effects of the parameters such as initial dye concentration and temperature on the removal of the dye were studied. Equilibrium was achieved in 120 min. Adsorption capacity was found to be dependent on the initial concentration of dye solution, and maximum adsorption was found to be 76 mg/g at 100 mg/L of TZ. The adsorption capacity at equilibrium ( q e) increased from 22.6 to 76 mg/g with an increase in the initial dye concentrations from 25 to 100 mg/L. The thermodynamic parameters such as change in free energy (Δ G 0), enthalpy (Δ H 0) and entropy (Δ S 0) were determined and the positive value of (Δ H) 78.1 (K J mol-1) revealed that adsorption efficiency increased with an increase in the process temperature. In fixed-bed column experiments, the effect of selected operating parameters such as bed depth, flow rate and initial dye concentration on the adsorption capacity was evaluated. Increase in bed height of adsorption columns leads to an extension of breakthrough point as well as the exhaustion time of adsorbent. However, the maximum adsorption capacities decrease with increases of flow rate. The breakthrough data fitted well to bed depth service time and Thomas models with high coefficient of determination, R 2 ≥ 94.
NASA Astrophysics Data System (ADS)
Lei, Peng-cheng; Shen, Xian-jiang; Li, Yang; Guo, Min; Zhang, Mei
2016-07-01
A simple and practical method for the synthesis of zeolite 4A from bauxite tailings is presented in this paper. Systematic investigations were carried out regarding the capacity of zeolite 4A to remove Cr(III) from aqueous solutions with relatively low initial concentrations of Cr(III) (5-100 mg·L-1). It is found that the new method is extremely cost-effective and can significantly contribute in decreasing environmental pollution caused by the dumping of bauxite tailings. The Cr(III) removal capacity highly depends on the initial pH value and concentration of Cr(III) in the solution. The maximum removal capacity of Cr(III) was evaluated to be 85.1 mg·g-1 for zeolite 4A, measured at an initial pH value of 4 and an initial Cr(III) concentration of 5 mg·L-1. This approach enables a higher removal capacity at lower concentrations of Cr(III), which is a clear advantage over the chemical precipitation method. The removal mechanism of Cr(III) by zeolite 4A was examined. The results suggest that both ion exchange and the surface adsorption-crystallization reaction are critical steps. These two steps collectively resulted in the high removal capacity of zeolite 4A to remove Cr(III).
Electrochemical Testing of Ni-Cr-Mo-Gd Alloys
DOE Office of Scientific and Technical Information (OSTI.GOV)
T. E. Lister; R. E. Mizia; H. Tian
2005-10-01
The waste package site recommendation design specified a boron-containing stainless steel, Neutronit 976/978, for fabrication of the internal baskets that will be used as a corrosion-resistant neutron-absorbing material. Recent corrosion test results gave higher-than-expected corrosion rates for this material. The material callout for these components has been changed to a Ni-Cr-Mo-Gd alloy (ASTM-B 932-04, UNS N06464) that is being developed at the Idaho National Laboratory. This report discusses the results of initial corrosion testing of this material in simulated in-package environments that could contact the fuel baskets after breach of the waste package outer barrier. The corrosion test matrix wasmore » executed using the potentiodynamic and potentiostatic electrochemical test techniques. The alloy performance shows low rates of general corrosion after initial removal of a gadolinium-rich second phase that intersects the surface. The high halide-containing test solutions exhibited greater tendencies toward initiation of crevice corrosion.« less
Lam, Yun Fung; Lee, Lai Yee; Chua, Song Jun; Lim, Siew Shee; Gan, Suyin
2016-05-01
Lansium domesticum peel (LDP), a waste material generated from the fruit consumption, was evaluated as a biosorbent for nickel removal from aqueous media. The effects of dosage, contact time, initial pH, initial concentration and temperature on the biosorption process were investigated in batch experiments. Equilibrium data were fitted by the Langmuir, Freundlich, Temkin and Dubinin-Radushkevich models using nonlinear regression method with the best-fit model evaluated based on coefficient of determination (R(2)) and Chi-square (χ(2)). The best-fit isotherm was found to be the Langmuir model exhibiting R(2) very close to unity (0.997-0.999), smallest χ(2) (0.0138-0.0562) and largest biosorption capacity (10.1mg/g) at 30°C. Kinetic studies showed that the initial nickel removal was rapid with the equilibrium state established within 30min. Pseudo-second-order model was the best-fit kinetic model indicating the chemisorption nature of the biosorption process. Further data analysis by the intraparticle diffusion model revealed the involvement of several rate-controlling steps such as boundary layer and intraparticle diffusion. Thermodynamically, the process was exothermic, spontaneous and feasible. Regeneration studies indicated that LDP biosorbent could be regenerated using hydrochloric acid solution with up to 85% efficiency. The present investigation proved that LDP having no economic value can be used as an alternative eco-friendly biosorbent for remediation of nickel contaminated water. Copyright © 2016 Elsevier Inc. All rights reserved.
Do vitreous fibers break in the lung?
Eastes, Walter; Baron, Paul A; Baier, Robert E; Guldberg, Marianne; Potter, Russell
2007-04-01
In order to determine whether breakage of long vitreous fibers in the lung could be responsible for removing significant numbers of these fibers, an intratracheal instillation study was done with a preparation consisting of mostly long fibers of two different types. Following instillation of both fibers, laboratory rats were sacrificed at 6 times up to 14 days. The NK (conventional borosilicate glass) fiber preparation had about 20% short fibers (length < or = 15 microm) initially, and fibers recovered from the lungs remained at that proportion for the entire 14 days. But the HT (a new rock or stone wool) fiber preparation, which had about 5% short fibers initially, jumped to about 50% short fibers at 2 days and remained at that proportion for the rest of the study. The appearance of many short HT fibers where there were few initially is conclusive evidence that these long fibers break, and it explains their rapid removal from the lung. Since the HT fibers dissolve rapidly at acid pH, but slowly at the near neutral pH of the extracellular lung fluid, it is likely that acid attack by phagocytic cells is causing the long fibers to dissolve and break. The long NK fibers dissolve rapidly at neutral pH but slowly at acid pH and thus appear to clear by more or less uniform dissolution without apparent breakage. The long fibers of these two kinds are removed rapidly at about the same rate, but by a different mechanism.
High Pb concentration stress on Typha latifolia growth and Pb removal in microcosm wetlands.
Han, Jianqiu; Chen, Fengzhen; Zhou, Yumei; Wang, Chaohua
2015-01-01
When constructed wetlands are used to treat high-Pb wastewater, Pb may become a stress to wetland plants, which subsequently reduces treatment performance and the other ecosystem services. To facilitate the design and operation of constructed wetlands for treatment of Pb-rich wastewater, we investigated the irreversible inhibitory level of Pb for Typha latifolia through experiments in microcosm wetlands. Seven horizontal subsurface flow constructed wetlands were built with rectangular plastic tanks and packed with marble chips and sand. All wetlands were transplanted with nine stems of Typha latifolia each. The wetlands were batch operated in a greenhouse with artificial wastewater (10 L each) for 12 days. Influent to the seven wetlands had different concentrations of Pb: 0 mg/L, 10 mg/L, 25 mg/L, 50 mg/L, 100 mg/L, 200 mg/L, and 500 mg/L, respectively. The results suggested that leaf chlorophyll relative content, relative growth rate, photosynthetic characteristics, activities of superoxide dismutase, peroxidase, and content of malondialdehyde were not affected when initial Pb concentration was at 100 mg/L and below. But when initial Pb concentration was above 100 mg/L, all of them were seriously affected. We conclude that high Pb concentrations wastewater could inhibit the growth of Typha latifolia and decrease the removal rate of wetlands.
Treatment of amoxicillin by O3/Fenton process in a rotating packed bed.
Li, Mo; Zeng, Zequan; Li, Yingwen; Arowo, Moses; Chen, Jianfeng; Meng, Hong; Shao, Lei
2015-03-01
In this study, simulated amoxicillin wastewater was treated by the O3/Fenton process in a rotating packed bed (RPB) and the results were compared with the Fenton process and the O3 followed by Fenton (O3 + Fenton) process. The chemical oxygen demand (COD) removal rate and the ratio of 5-day biological oxygen demand to chemical oxygen demand (BOD5/COD) in the O3/Fenton process were approximately 17% and 26%, respectively, higher than those in the O3 + Fenton process with an initial pH of 3. The COD removal rate of the amoxicillin solution reached maximum at the Fe(II) concentration of 0.6 mM, temperature of 25 °C, rotation speed of 800 rpm and initial pH of 3. The BOD5/COD of the amoxicillin solution increased from 0 to 0.38 after the solution was treated by the O3/Fenton process. Analysis of the intermediates indicated that the pathway of amoxicillin degradation in the O3/Fenton process was similar to that in the O3 + Fenton process. Contrast experiment results showed that amoxicillin degradation was significantly intensified in the RPB. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kilgo, John C.; Vukovich, Mark; Ray, H. Scott
Predation by coyotes (Canis latrans) on white-tailed deer (Odocoileus virginianus) neonates has led to reduced recruitment in many deer populations in southeastern North America. This low recruitment combined with liberal antlerless deer harvest has resulted in declines in some deer populations, and consequently, increased interest in coyote population control. We investigated whether neonate survival increased after coyote removal, whether coyote predation on neonates was additive to other mortality sources, and whether understory vegetation density affected neonate survival. We monitored neonate survival for 4 years prior to (2006–2009) and 3 years during (2010–2012) intensive coyote removal on 3 32-km 2 unitsmore » on the United States Department of Energy’s Savannah River Site, South Carolina. We removed 474 coyotes (1.63 coyotes/km 2 per unit per year), reducing coyote abundance by 78% from pre-removal levels. The best model (w i = 0.927) describing survival probability among 216 radio-collared neonates included a within-year quadratic time trend variable, date of birth, removal treatment, and a varying removal year effect. Under this model, survival differed between pre-treatment and removal periods and it differed among years during the removal period, being >100% greater than pre-treatment survival (0.228) during the first removal year (0.513), similar to pre-treatment survival during the second removal year (0.202), and intermediate during the third removal year (0.431). Despite an initial increase, the overall effect of coyote removal on neonate survival was modest. Mortality rate attributable to coyote predation was lowest during the first removal year (0.357) when survival was greatest, but the mortality rate from all other causes did not differ between the pretreatment period and any year during removals, indicating that coyote predation acted as an additive source of mortality. Survival probability was not related to vegetation cover, either directly or in interaction with coyote abundance. When the objective is to increase the recruitment of white-tailed deer, we conclude that neither coyote control nor vegetation management appear effective. Reduction of the antlerless harvest may be necessary to meet this objective, but this harvest strategy warrants additional research in Southeastern deer populations.« less
Cleaning of optical surfaces by excimer laser radiation
NASA Astrophysics Data System (ADS)
Mann, K.; Wolff-Rottke, B.; Müller, F.
1996-04-01
The effect of particle removal from Al mirror surfaces by the influence of pulsed UV laser radiation has been studied. The investigations are closely related to the demands of astronomers, who are looking for a more effective way to clean future very large telescope (VLT) mirrors [1]. A systematic parameter study has been performed in order to determine the irradiation conditions which yield the highest dust removal efficiency (i.e. reflectivity increase) on contaminated samples. The particle removal rate increases with increasing laser fluence, being limited however by the damage threshold of the coating. Data indicate that on Al coated BK7 and Zerodur samples KrF laser radiation yields the optimum result, with cleaning efficiencies comparable to polymer film stripping. The initial reflectivity of the clean coating can nearly be restored, in particular when an additional solvent film on the sample surface is applied.
Phytoremediation of Heavy Metals in Contaminated Water and Soil Using Miscanthus sp. Goedae-Uksae 1.
Bang, Jihye; Kamala-Kannan, Seralathan; Lee, Kui-Jae; Cho, Min; Kim, Chang-Hwan; Kim, Young-Jin; Bae, Jong-Hyang; Kim, Kyong-Ho; Myung, Hyun; Oh, Byung-Taek
2015-01-01
The aim of this study is to characterize the heavy metal phytoremediation potential of Miscanthus sp. Goedae-Uksae 1, a hybrid, perennial, bio-energy crop developed in South Korea. Six different metals (As, Cu, Pb, Ni, Cd, and Zn) were used for the study. The hybrid grass effectively absorbed all the metals from contaminated soil. The maximum removal was observed for As (97.7%), and minimum removal was observed for Zn (42.9%). Similarly, Goedae-Uksae 1 absorbed all the metals from contaminated water except As. Cd, Pb, and Zn were completely (100%) removed from contaminated water samples. Generally, the concentration of metals in roots was several folds higher than in shoots. Initial concentration of metals highly influenced the phytoremediation rate. The results of the bioconcentration factor, translocation factor, and enrichment coefficient tests indicate that Goedae-Uksae 1 could be used for phytoremediation in a marginally contaminated ecosystem.
Padhi, Soumesh Kumar; Tripathy, Swetaleena; Mohanty, Sriprakash; Maiti, Nikhil Kumar
2017-05-01
Heterotrophic bacterium, Enterobacter cloacae CF-S27 exhibited simultaneous nitrification and aerobic denitrification in presence of high concentration of hydroxylamine. With the initial nitrogen concentration of 100mgL -1 h -1 , ammonium, nitrate and nitrite removal efficiencies were 81%, 99.9% and 92.8%, while the corresponding maximum removal rates reached as high as 11.6, 15.1 and 11.2mgL -1 h -1 respectively. Quantitative amplification by real time PCR and enzyme assay demonstrated that hydroxylamine reductase gene (hao) is actively involved in hetrotrophic nitrification and aerobic denitrification process of Enterobacter cloacae CF-S27. PCR primers were designed targeting amplification of hao gene from diversified environmental soil DNA. The strain Enterobacter cloacae CF-S27 significantly maintained the undetectable amount of dissolved nitrogen throughout 60days of zero water exchange fish culture experiment in domestic wastewater. Copyright © 2017 Elsevier Ltd. All rights reserved.
Dynamic pesticide removal with activated carbon fibers.
Martín-Gullón, I; Font, R
2001-02-01
Rapid small-scale minicolumn tests were carried out to simulate the atrazine adsorption in water phase with three pelletized pitch-based activated carbon fibers (ACF) and one commercial granular activated carbon (GAC). Initial atrazine solutions were prepared with pretreated ground water. Minicolumn tests showed that the performance of highly activated carbon fibers (surface area of 1700 m2/g) is around 7 times better than the commercial GAC (with surface area at around 1100 m2/g), whereas carbon fibers with medium activation degree (surface area of 1500 m2/g) had a removal efficiency worse than the commercial carbon. The high removal efficiency of the highly activated ACF is due to the wide-opened microstructure of the material, with an appreciable contribution of the low size mesopores, maintaining at these conditions a fast kinetic adsorption rate rather than a selective adsorbent for micropollutants vs. natural organic matter.
NASA Astrophysics Data System (ADS)
Fadeyi, M. O.; Weschler, C. J.; Tham, K. W.
This study examined the impact of recirculation rates (7 and 14 h -1), ventilation rates (1 and 2 h -1), and filtration on secondary organic aerosols (SOAs) generated by ozone of outdoor origin reacting with limonene of indoor origin. Experiments were conducted within a recirculating air handling system that serviced an unoccupied, 236 m 3 environmental chamber configured to simulate an office; either no filter, a new filter or a used filter was located downstream of where outdoor air mixed with return air. For otherwise comparable conditions, the SOA number and mass concentrations at a recirculation rate of 14 h -1 were significantly smaller than at a recirculation rate of 7 h -1. This was due primarily to lower ozone concentrations, resulting from increased surface removal, at the higher recirculation rate. Increased ventilation increased outdoor-to-indoor transport of ozone, but this was more than offset by the increased dilution of SOA derived from ozone-initiated chemistry. The presence of a particle filter (new or used) strikingly lowered SOA number and mass concentrations compared with conditions when no filter was present. Even though the particle filter in this study had only 35% single-pass removal efficiency for 100 nm particles, filtration efficiency was greatly amplified by recirculation. SOA particle levels were reduced to an even greater extent when an activated carbon filter was in the system, due to ozone removal by the carbon filter. These findings improve our understanding of the influence of commonly employed energy saving procedures on occupant exposures to ozone and ozone-derived SOA.
Limbri, Hendy; Gunawan, Cindy; Thomas, Torsten; Smith, Andrew; Scott, Jason; Rosche, Bettina
2014-01-01
Methane emitted by coal mine ventilation air (MVA) is a significant greenhouse gas. A mitigation strategy is the oxidation of methane to carbon dioxide, which is approximately twenty-one times less effective at global warming than methane on a mass-basis. The low non-combustible methane concentrations at high MVA flow rates call for a catalytic strategy of oxidation. A laboratory-scale coal-packed biofilter was designed and partially removed methane from humidified air at flow rates between 0.2 and 2.4 L min−1 at 30°C with nutrient solution added every three days. Methane oxidation was catalysed by a complex community of naturally-occurring microorganisms, with the most abundant member being identified by 16S rRNA gene sequence as belonging to the methanotrophic genus Methylocystis. Additional inoculation with a laboratory-grown culture of Methylosinus sporium, as investigated in a parallel run, only enhanced methane consumption during the initial 12 weeks. The greatest level of methane removal of 27.2±0.66 g methane m−3 empty bed h−1 was attained for the non-inoculated system, which was equivalent to removing 19.7±2.9% methane from an inlet concentration of 1% v/v at an inlet gas flow rate of 1.6 L min−1 (2.4 min empty bed residence time). These results show that low-cost coal packing holds promising potential as a suitable growth surface and contains methanotrophic microorganisms for the catalytic oxidative removal of methane. PMID:24743729
Saber, Ali; Tafazzoli, Milad; Mortazavian, Soroosh; James, David E
2018-02-01
Two common wetland plants, Pampas Grass (Cortaderia selloana) and Lucky Bamboo (Dracaena sanderiana), were used in hydroponic cultivation systems for the treatment of simulated high-sulfate wastewaters. Plants in initial experiments at pH 7.0 removed sulfate more efficiently compared to the same experimental conditions at pH 6.0. Results at sulfate concentrations of 50, 200, 300, 600, 900, 1200, 1500 and 3000 mg/L during three consecutive 7-day treatment periods with 1-day rest intervals, showed decreasing trends of both removal efficiencies and uptake rates with increasing sulfate concentrations from the first to the second to the third 7-day treatment periods. Removed sulfate masses per unit dry plant mass, calculated after 23 days, showed highest removal capacity at 600 mg/L sulfate for both plants. A Langmuir-type isotherm best described sulfate uptake capacity of both plants. Kinetic studies showed that compared to pseudo first-order kinetics, pseudo-second order kinetic models slightly better described sulfate uptake rates by both plants. The Elovich kinetic model showed faster rates of attaining equilibrium at low sulfate concentrations for both plants. The dimensionless Elovich model showed that about 80% of sulfate uptake occurred during the first four days' contact time. Application of three 4-day contact times with 2-day rest intervals at high sulfate concentrations resulted in slightly higher uptakes compared to three 7-day contact times with 1-day rest intervals, indicating that pilot-plant scale treatment systems could be sized with shorter contact times and longer rest-intervals. Copyright © 2017 Elsevier Ltd. All rights reserved.
Nguyen, Diem-Mai Kim; Imai, Tsuyoshi; Dang, Thanh-Loc Thi; Kanno, Ariyo; Higuchi, Takaya; Yamamoto, Koichi; Sekine, Masahiko
2018-03-01
This paper presents the results from using a physical absorption process to absorb gaseous CO 2 mixed with N 2 using water by producing tiny bubbles via a liquid-film-forming device (LFFD) that improves the solubility of CO 2 in water. The influence of various parameters-pressure, initial CO 2 concentration, gas-to-liquid ratios, and temperature-on the CO 2 removal efficiency and its absorption rate in water were investigated and estimated thoroughly by statistical polynomial models obtained by the utilization of the response surface method (RSM) with a central composite design (CCD). Based on the analysis, a high efficiency of CO 2 capture can be reached in conditions such as low pressure, high CO 2 concentration at the inlet, low gas/liquid ratio, and low temperature. For instance, the highest removal efficiency in the RSM-CCD experimental matrix of nearly 80% occurred for run number 20, which was conducted at 0.30MPa, CO 2 concentration of 35%, gas/liquid ratio of 0.71, and temperature of 15°C. Furthermore, the coefficients of determination, R 2 , were 0.996 for the removal rate and 0.982 for the absorption rate, implying that the predicted values computed by the constructed models correlate strongly and fit well with the experimental values. The results obtained provide essential information for implementing this method properly and effectively and contribute a promising approach to the problem of CO 2 capture in air pollution treatment. Copyright © 2017. Published by Elsevier B.V.
Variables affecting efficiency of molasses fermentation wastewater ozonation.
Coca, M; Peña, M; González, G
2005-09-01
The main operating variables affecting ozonation efficiencies of wastewater from beet molasses alcoholic fermentation have been studied. Semibatch experiments have been performed in order to analyze the influence of pH, bicarbonate ion, temperature and stirring rate on color and organic matter removals. The efficiencies were similar regardless of the pH, which indicates that direct reactions of ozone with wastewater organics were predominant to radical reactions. Gel permeation chromatography confirmed the reduction in the concentration of organics absorbing light at 475 nm after ozonation. The elimination of bicarbonate ion, strong inhibitor of hydroxyl radical reactions, yielded an improvement in both color and COD reduction efficiencies. Acidification for removing bicarbonate ions produced a shift of colored compounds to smaller molecular weights. The highest efficiencies were achieved at 40 degrees C. Color and COD reductions at 40 degrees C were about 90% and 37%, respectively. In no case, the percentage of TOC removed was higher than 10-15%. Stirring rate had a slightly positive effect during the first stage of the ozonation showing that mass transfer played a role only during the initial reaction phase when direct attack of ozone molecules to aromatic/olefinic structures of colored substances was the predominant pathway.
Custelcean, Radu; Sloop, Frederick V.; Rajbanshi, Arbin; ...
2014-12-04
We measured the thermodynamics and kinetics of crystallization of sodium sulfate with a tripodal tris-urea receptor (L1) from aqueous alkaline solutions in the 15 55 C temperature range, with the goal of identifying the optimal conditions for efficient and quick sulfate removal from nuclear wastes. The use of radiolabeled Na 2 35SO 4 provided a practical way to monitor the sulfate concentration in solution by liquid scintillation counting. Our results are consistent with a two-step crystallization mechanism, involving relatively quick dissolution of crystalline L1 followed by the rate-limiting crystallization of the Na 2SO 4(L1) 2(H 2O) 4 capsules. We foundmore » that temperature exerted relatively little influence over the equilibrium sulfate concentration, which ranged between 0.004 and 0.011 M. Moreover, this corresponds to 77 91% removal of sulfate from a solution containing 0.0475 M initial sulfate concentration, as found in a typical Hanford waste tank. The apparent pseudo-first-order rate constant for sulfate removal increased 20-fold from 15 to 55 C, corresponding to an activation energy of 14.1 kcal/mol. At the highest measured temperature of 55 C, 63% and 75% of sulfate was removed from solution within 8 h and 24 h, respectively.« less
Nutrients removal from artificial bathroom greywater using Botryococcus sp. strain
NASA Astrophysics Data System (ADS)
Mohamed, RMSR; Al-Gheethi, AA; Wurochekke, AA; Maizatul, AY; Matias-Peralta, HM; Kassim, AH Mohd
2018-04-01
The discharge of untreated bathroom greywater directly into drain is a most common practice in the rural area. The uncontrolled discharge of greywater from the village houses escalates the pollution among Malaysian river and provide insanitary environment through mosquito and flies breeding grounds. Therefore, the current work aimed to investigate the potential of Botryococcus sp. for removing total nitrogen (TN), total phosphorus (TP) and total organic carbon (TOC) from artificial bathroom greywater and to determine the bio-kinetic removal rate for these parameters. The artificial bathroom greywater was prepared by using regular brands used in the community, the bathroom greywater quality was tested for BOD, COD, SS, pH, and Turbidity. The removal process was conducted in the lab scale with 108 cell mL-1 of Botryococcus sp. The removal of TN, TP and TOC was measured in interval of 3, 5 and 7 days. The results deduced that Botryococcus sp. removed 51.5% of TN, 49.5% of TP and 42.6% of TOC. Moreover, the bio-kinetic model studies, revealed that the specific removal rate of TN, TP and TOC have a significant relationship with initial concentration in the artificial greywater (R2 = 0.63, 0.95 and 0.95 respectively). The kinetic coefficient of greywater parameters removed by Botryococcus sp. was determined as k=0.357 mg TN 1 log10 cell mL-1 d-1 and km=31.33 mg L-1 (R2=0.73), k=4.58 mg TP 1 log10 cell mL-1 d-1 and km=283.86 mg L-1 (R2=0.95), k=7.9 mg TOC 1 log10 cell mL-1 d-1 and km=322.32 mg L-1 (R2=0.97). The bio-kinetic model indicated that more than 90% of TN, TP and TOC was taken place as a response for Botryococcus sp.
Mehrdad, M; Park, H; Ramalingam, K; Fillos, J; Beckmann, K; Deur, A; Chandran, K
2014-01-01
New York City Environmental Protection in conjunction with City College of New York assessed the application of the anammox process in the reject water treatment using a moving bed biofilm reactor (MBBR) located at the 26th Ward wastewater treatment plant, in Brooklyn, NY. The single-stage nitritation/anammox MBBR was seeded with activated sludge and consequently was enriched with its own 'homegrown' anammox bacteria (AMX). Objectives of this study included collection of additional process kinetic and operating data and assessment of the effect of nitrogen loading rates on process performance. The initial target total inorganic nitrogen removal of 70% was limited by the low alkalinity concentration available in the influent reject water. Higher removals were achieved after supplementing the alkalinity by adding sodium hydroxide. Throughout startup and process optimization, quantitative real-time polymerase chain reaction (qPCR) analyses were used for monitoring the relevant species enriched in the biofilm and in the suspension. Maximum nitrogen removal rate was achieved by stimulating the growth of a thick biofilm on the carriers, and controlling the concentration of dissolved oxygen in the bulk flow and the nitrogen loading rates per surface area; all three appear to have contributed in suppressing nitrite-oxidizing bacteria activity while enriching AMX density within the biofilm.
A Contribution to the Problem of Initiation of a Combustion Source in an Oil-Saturated Bed
NASA Astrophysics Data System (ADS)
Koznacheev, I. A.; Dobrego, K. V.
2013-11-01
The problem on in-situ self-ignition of an oil-saturated bed under the conditions of forced filtration of an oxygen-containing gas has been solved with analytical and numerical methods with account of the burnout of a deficient gas component. The influence of the burnout of this component and of convective removal of heat from the bed on the time of its self-ignition has been determined. Recommendations for the optimum regime of initiation of the self-ignition of the bed with account of variation of the blast flow rate and the oxygen content have been given.
Modeling of the adsorptive removal of arsenic(III) using plant biomass: a bioremedial approach
NASA Astrophysics Data System (ADS)
Roy, Palas; Dey, Uttiya; Chattoraj, Soumya; Mukhopadhyay, Debasis; Mondal, Naba Kumar
2017-06-01
In the present work, the possibility of using a non-conventional finely ground (250 μm) Azadirachta indica (neem) bark powder [AiBP] has been tested as a low-cost biosorbent for the removal of arsenic(III) from water. The removal of As(III) was studied by performing a series of biosorption experiments (batch and column). The biosorption behavior of As(III) for batch and column operations were examined in the concentration ranges of 50-500 µg L-1 and 500.0-2000.0 µg L-1, respectively. Under optimized batch conditions, the AiBP could remove up to 89.96 % of As(III) in water system. The artificial neural network (ANN) model was developed from batch experimental data sets which provided reasonable predictive performance ( R 2 = 0.961; 0.954) of As(III) biosorption. In batch operation, the initial As(III) concentration had the most significant impact on the biosorption process. For column operation, central composite design (CCD) was applied to investigate the influence on the breakthrough time for optimization of As(III) biosorption process and evaluation of interacting effects of different operating variables. The optimized result of CCD revealed that the AiBP was an effective and economically feasible biosorbent with maximum breakthrough time of 653.9 min, when the independent variables were retained at 2.0 g AiBP dose, 2000.0 µg L-1 initial As(III) concentrations, and 3.0 mL min-1 flow rate, at maximum desirability value of 0.969.
Liu, Yuanyuan; Mou, Haiyan; Chen, Liqun; Mirza, Zakaria A; Liu, Li
2015-11-15
Permeable reactive barriers (PRBs) are efficient technologies for in situ remediation of contaminated groundwater, the effectiveness of which greatly depends on the reactive media filled. Natural pyrite is an iron sulfide material with a very low content of iron and sulfur, and a mining waste which is a potential material for Cr(VI) immobilization. In this study, we conducted a series of batch tests to research the effects of typical environmental factors on Cr(VI) removal and also simulated PRB filled with natural pyrite to investigate its effectiveness, in order to find a both environmentally and economically fine method for groundwater remediation. Batch tests showed that pH had the significant impact on Cr(VI) removal with an apparently higher efficiency under acidic conditions, and dissolved oxygen (DO) would inhibit Cr(VI) reduction; a relatively high initial Cr(VI) concentration would decrease the rate of Cr(VI) sorption; ionic strength and natural organic matter resulted in no significant effects on Cr(VI) removal. Column tests demonstrated that the simulated PRB with natural pyrite as the reactive media was considerably effective for removing Cr(VI) from groundwater, with a sorption capability of 0.6222 mg Cr per gram of natural pyrite at an initial Cr(VI) concentration of 10mg/L at pH 5.5 in an anoxic environment. Copyright © 2015 Elsevier B.V. All rights reserved.
Saejung, Chewapat; Thammaratana, Thani
2016-12-01
Utilization of photosynthetic bacteria (PSB) for wastewater treatment and production of biomass for economical single cell protein production is a feasible option. In this study, Rhodopseudomonas sp. CSK01 was used for municipal wastewater treatment and the effect of initial pH, light intensity and additional carbon source was investigated. Optimum chemical oxygen demand (COD) removal and biomass production were achieved when the initial pH and light intensity were 7 and 4000 lux, respectively. The specific growth rate, biomass yield and biomass productivity were found to be 0.4/d, 3.2 g/g COD and 2.1 g/L/d, respectively, which were improved by 100%, 167% and 200% relative to the original condition. Under the optimal conditions, COD removal reached 85% and maximum biomass was 6.2 g/L accomplished within three days of cultivation. The biomass had a relatively high protein content (60.1%) consisting of all essential amino acids. The contents of histidine, lysine, phenylalanine and leucine were superior to those of the previously described PSB. Results showed that COD removal was not improved in the presence of additional carbon sources (glucose, sucrose and malic acid). The addition of malic acid significantly increased the biomass accumulation by 279% relative to the original condition, whereas COD removal was declined due to carbon catabolite repression. In this study, PSB biomass recovery and catabolite repression are proposed in municipal wastewater treatment by Rhodopseudomonas sp.
Smith, Benjamin T; Knutsen, Jeffrey S; Davis, Robert H
2010-05-01
The cellulose hydrolysis kinetics during batch enzymatic saccharification are typified by a rapid initial rate that subsequently decays, resulting in incomplete conversion. Previous studies suggest that changes associated with the solution, substrate, or enzymes may be responsible. In this work, kinetic experiments were conducted to determine the relative magnitude of these effects. Pretreated corn stover (PCS) was used as a lignocellulosic substrate likely to be found in a commercial saccharification process, while Avicel and Kraft lignin were used to create model substrates. Glucose inhibition was observed by spiking the reaction slurry with glucose during initial-rate experiments. Increasing the glucose concentration from 7 to 48 g/L reduced the cellulose conversion rate by 94%. When product sugars were removed using ultrafiltration with a 10 kDa membrane, the glucose-based conversion increased by 9.5%. Reductions in substrate reactivity with conversion were compared directly by saccharifying PCS and Avicel substrates that had been pre-reacted to different conversions. Reaction of substrate with a pre-conversion of 40% resulted in about 40% reduction in the initial rate of saccharification, relative to fresh substrate with identical cellulose concentration. Overall, glucose inhibition and reduced substrate reactivity appear to be dominant factors, whereas minimal reductions of enzyme activity were observed.
Antoniou, Dimitris; Christopoulos-Geroulanos, George
2011-01-01
Although foreign body ingestion is a common problem in children, there are no clear guidelines regarding the management of ingested foreign bodies. The aim of this study was to evaluate the effectiveness of our protocol in the work-up and management of children with ingested foreign bodies. Between September 2002 and August 2010, a total of 675 children with suspected foreign body ingestion were seen in the emergency department. At initial presentation, the majority of foreign bodies were located in the stomach (n=392, 58.1%) followed by the small intestine (n=221, 32.7%) and esophagus (n=62, 9.2%). Based on our protocol, 84 (12.4%) patients were admitted at initial presentation, and 5 after a 48-hour observation period at home; 61 (9%) required prompt endoscopic removal. Sixty-eight (10.1%) patients returned for endoscopic removal after a four-week observation period, and 3 (0.4%) patients underwent delayed surgery due to complications. The overall success rate of endoscopic retrieval was 96.1%. There were no major complications. The majority of ingested foreign bodies will pass spontaneously and most children can be safely observed at home. Selective endoscopic intervention is the preferable method for the removal of ingested foreign bodies in pediatric patients.
Heterogeneous selenite reduction by zero valent iron steel wool.
Li, Ziyan; Huang, Donglin; McDonald, Louis M
2017-02-01
Mine drainage from the low-sulfur surface coal mines in southern West Virginia, USA, is circumneutral (pH > 6) but contains elevated selenium (Se) concentrations. Removal of selenite ions from aqueous solutions under anoxic condition at pH 6-8.5 by zero valent iron steel wool (ZVI-SW) was investigated in bench-scale kinetic experiments using wet chemical, microscopic and spectroscopic techniques (X-ray photoelectron spectroscopy). ZVI-SW could effectively and efficiently remove Se IV from solution with pH 6-8.5. A two-step removal mechanism was identified for Se IV reduction by ZVI-SW. The proposed mechanism was electrochemical reduction of Se IV by Fe 0 in an initial lag stage, followed by a faster heterogeneous reduction, mediated by an Fe II -bearing phase (hydroxide or green rust). Solution pH was a critical factor for the kinetic rate in the lag stage (0.33 h -1 for pH > 8 and 0.10 h -1 for pH 6-8). The length of lag stage was 20-30 min as determined by the time for dissolved Fe II concentration to reach 0.30 ± 0.04 mg L -1 which was critical for induction of the faster stage. About 65% of the initial Se IV was reduced to Se 0 , the primary reductive product in both stages.
Ammonia-nitrogen and Phosphate Reduction by Bio-Filter using Factorial Design
NASA Astrophysics Data System (ADS)
Kasmuri, Norhafezah; Ashikin Mat Damin, Nur; Omar, Megawati
2018-02-01
Untreated landfill leachate is known to have endangered the environment. As such new treatment must be sought to ensure its cost-effective and sustainable treatment. Thus this paper reports the effectiveness of bio-filter to remove pollutants. In this research, the reduction of nutrients concentration was evaluated in two conditions: using bio-filter and without bio-filter. Synthetic wastewater was used in the batch culture. It was conducted within 21 days in the initial mediums of 100 mg/L ammonia-nitrogen. The nitrification medium consisted of 100 mg/L of ammonia-nitrogen while the nitrite assay had none. The petri dish experiment was also conducted to observe the existence of any colony. The results showed 22% of ammonia- nitrogen reduction and 33% phosphate in the nitrification medium with the bio-filter. The outcome showed that the bio-filter was capable to reduce the concentration of pollutants by retaining the slow growing bacteria (AOB and NOB) on the plastic carrier surface. The factorial design was applied to study the effect of the initial ammonia-nitrogen concentration and duration on nitrite-nitrogen removal. Finally, a regression equation was produced to predict the rate of nitrite-nitrogen removal without conducting extended experiments and to reduce the number of trials experiment.
Removal of dieldrin from aqueous solution by a novel triolein-embedded composite adsorbent.
Ru, Jia; Liu, Huijuan; Qu, Jiuhui; Wang, Aimin; Dai, Ruihua
2007-03-06
In this study, a novel triolein-embedded activated carbon composite adsorbent (CA-T) was prepared and applied for the adsorption and removal of dieldrin from aqueous systems. Experiments were carried out to investigate the adsorption behavior of dieldrin on CA-T, including adsorption isotherms, adsorption kinetics, the influence of initial concentration, temperature, shaking speed, pH and the addition of humic acid (HA) on adsorption. The adsorption isotherms accorded with Freundlich equation. Three kinetics models, including pseudo-first-order, pseudo-second-order and intraparticle diffusion models, were used to fit the experimental data. By comparing the correlation coefficients, it was found that both pseudo-second-order and intraparticle diffusion models were used to well describe the adsorption of dieldrin on CA-T. The addition of HA had little effect on dieldrin adsorption by CA-T. Results indicated that CA-T appeared to be a promising adsorbent for removing lipophilic dieldrin in trace amount, which was advantageous over pure granular activated carbon (GAC). The adsorption rate increased with increasing shaking speed, initial concentration and temperature, and remained almost unchanged in the pH range of 4-8. Thermodynamic calculations indicated that the adsorption reaction was spontaneous with a high affinity and the adsorption was an endothermic reaction.
Yang, Kai; Zhang, Jing; Yang, Tao; Wang, Hongyu
2016-01-01
In this study, response surface methodology (RSM) based on three-variable-five-level central composite rotatable design was used to analyze the effects of combined and individual operating parameters (biomass dose, initial concentration of Cr(VI) and pH) on the Cr(VI) adsorption capacity of dried Bacillus cereus. A quadratic polynomial equation was obtained to predict the adsorbed Cr(VI) amount. Analysis of variance showed that the effect of biomass dose was the key factor in the removal of Cr(VI). The maximum adsorbed Cr(VI) amount (30.93 mg g(-1)) was found at 165.30 mg L(-1), 2.96, and 3.01 g L(-1) for initial Cr(VI) concentration, pH, and biosorbent dosage, respectively. The surface chemical functional groups and microstructure of unloaded and Cr(VI)-loaded dried Bacillus cereus were identified by Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM), respectively. Besides, the results gained from these studies indicated that Langmuir isotherm and the second-order rate expression were suitable for the removal of Cr(VI) from wastewater. The results revealed RSM was an effective method for optimizing biosorption process, and dried Bacillus cereus had a remarkable performance on the removal of Cr(VI) from wastewater.
Russell, S M; Harrison, P M
1978-01-01
Horse ferritins from different organs show heterogeneity on electrofocusing in Ampholine gradients. Both ferritin and apoferritin from liver and spleen could be fractionated with respect to surface charge by serial precipitation with (NH4)2SO4. In the ferritin fractions, increasing iron content parallels increasing isoelectric point. After removal of their iron, those fractions which originally contained most iron accumulated added iron at the fastest rates. When unfractionated ferritins from different organs were compared the average isoelectric point increased in order spleen less than liver less than kidney less than heart. The order of initial rates of iron uptake by the apoferritins was spleen greater than kidney greater than heart and initial average iron contents also followed this order. The relatively low rates of iron accumulation by iron-poor molecules may have been due to structural alteration, to degradation, to activation of the iron-rich molecules or to other factors. Images Fig. 1. Fig. 2. PMID:736908
Experimental binding of lead to a low cost on biosorbent: Nopal (Opuntia streptacantha).
Miretzky, Patricia; Muñoz, Carolina; Carrillo-Chávez, Alejandro
2008-03-01
The use of nopal cladodes (Opuntia streptacantha) as raw material for Pb(2+) biosorption was investigated. Batch experiments were carried out to determine Pb(2+) sorption capacity and the efficiency of the sorption process under different pH, initial Pb(2+) and nopal biomass concentrations. The experimental data showed a good fit to Langmuir and Freundlich isotherms models. The maximum adsorption capacity for Pb(2+) was 0.14 mmol g(-1) with an efficiency higher than 94% (pH 5.0 and 2.5 g L(-1) nopal biomass). The Pb(2+) kinetics were best described by the pseudo-second-order rate model. The rate constant, the initial sorption rate and the equilibrium sorption capacity were determined. The practical implication of this study is the development of an effective and economic technology in which the nopal biomass did not undergo any chemical or physical pretreatment, which added to nopal abundance in Mexico and its low cost makes it a good option for Pb(2+) removal from contaminated waters.
Sato, Keiichiro; Yamawaki, Yoshifumi
2014-08-01
In responses to looming objects, the praying mantis shows a defense behavior, which consists of retracting forelegs under the prothorax. The role of a looming-sensitive neuron in triggering this behavior was investigated by simultaneously recording the activity and behavioral responses of the neuron. The mantis initiated the defense behavior earlier in response to larger and slower looming stimuli. The time remaining to collision at defense initiation was linearly correlated with the ratio of the half-size of an approaching object to its speed (l/|v|), suggesting that the defense behavior occurred a fixed delay after the stimuli had reached a fixed angular threshold. Furthermore, the results suggested that high-frequency spikes of the looming-sensitive neuron were involved in triggering the defense behavior: the distribution of maximum firing rate for trials with defense was shifted to larger rates compared with trials without defense; the firing rate of the neuron exceeded 150 Hz ∼100 ms before the defense initiation regardless of stimulus parameters; when a looming stimulus ceased approach prematurely, high-frequency spikes were removed, and the occurrence of defense was reduced. Copyright © 2014 the American Physiological Society.
Oxidation behavior of a thermal barrier coating
NASA Technical Reports Server (NTRS)
Miller, R. A.
1984-01-01
Thermal barrier coatings, consisting of a plasma sprayed calcium silicate ceramic layer and a CoCrAlY or NiCrAlY bond coat, were applied on B-1900 coupons and cycled hourly in air in a rapid-response furnace to maximum temperatures of 1030, 1100, or 1160 C. Eight specimens were tested for each of the six conditions of bond-coat composition and temperature. Specimens were removed from test at the onset of failure, which was taken to be the formation of a fine surface crack visible at 10X magnification. Specimens were weighed periodically, and plots of weight gain vs time indicate that weight is gained at a parabolic rate after an initial period where weight was gained at a much greater rate. The high initial oxidation rate is thought to arise from the initially high surface area in the porous bond coat. Specimen life (time to first crack) was found to be a strong function of temperature. However, while test lives varied greatly with time, the weight gain at the time of specimen failure was quite insensitive to temperature. This indicates that there is a critical weight gain at which the coating fails when subjected to this test.
Babaei, Ali Akbar; Azari, Ali; Kalantary, Roshanak Rezaei; Kakavandi, Babak
2015-01-01
Herein, multi-wall carbon nanotubes (MWCNTs) were used as the carrier of nano-zero valent iron (nZVI) particles to fabricate a composite known as nZVI@MWCNTs. The composite was then characterized and applied in the nitrate removal process in a batch system under anoxic conditions. The influential parameters such as pH, various concentrations of nitrate and composite were investigated within 240 min of the reaction. The mechanism, kinetics and end-products of nitrate reduction were also evaluated. Results revealed that the removal nitrate percentage for nZVI@MWCNTs composite was higher than that of nZVI and MWCNTs alone. Experimental data from nitrate reduction were fitted to the Langmuir-Hinshelwood kinetic model. The values of observed rate constant (kobs) decreased with increasing the initial concentration of nitrate. Our experiments proved that the nitrate removal efficiency was favorable once both high amounts of nZVI@MWCNTs and low concentrations of nitrate were applied. The predominant end-products of the nitrate reduction were ammonium (84%) and nitrogen gas (15%). Our findings also revealed that ZVI@MWCNTs is potentially a good composite for removal/reduction of nitrate from aqueous solutions.
Removal of arsenic from aqueous solutions using waste iron columns inoculated with iron bacteria.
Azhdarpoor, Abooalfazl; Nikmanesh, Roya; Samaei, Mohammad Reza
2015-01-01
Arsenic contamination of water resources is one of the serious risks threatening natural ecosystems and human health. This study investigates arsenic removal using a waste iron column with and without iron bacteria in continuous and batch phases. In batch experiments, the effects of pH, contact time, initial concentration of arsenic and adsorbent dose were investigated. Results indicated that the highest arsenate removal efficiency occurred at pH 7 (96.76%). On increasing the amount of waste iron from 0.25 to 1 g, the removal rate changed from about 42.37%-96.70%. The results of continuous experiments on the column containing waste iron showed that as the empty bed contact time increased from 5 to 60 min, the secondary arsenate concentration changed from 23 to 6 µg/l. In experiments involving a waste iron column with iron bacteria, an increase in residence time from 5 to 60 min decreased the secondary arsenate concentration from 14.97 to 4.86 µg/l. The results of this study showed that waste iron containing iron bacteria is a good adsorbent for removal of arsenic from contaminated water.
Farhadi, Sajjad; Aminzadeh, Behnoush; Torabian, Ali; Khatibikamal, Vahid; Alizadeh Fard, Mohammad
2012-06-15
This work makes a comparison between electrocoagulation (EC), photoelectrocoagulation, peroxi-electrocoagulation and peroxi-photoelectrocoagulation processes to investigate the removal of chemical oxygen demand (COD) from pharmaceutical wastewater. The effects of operational parameters such as initial pH, current density, applied voltage, amount of hydrogen peroxide and electrolysis time on COD removal efficiency were investigated and the optimum operating range for each of these operating variables was experimentally determined. In electrocoagulation process, the optimum values of pH and voltage were determined to be 7 and 40 V, respectively. Desired pH and hydrogen peroxide concentration in the Fenton-based processes were found to be 3 and 300 mg/L, respectively. The amounts of COD, pH, electrical conductivity, temperature and total dissolved solids (TDS) were on-line monitored. Results indicated that under the optimum operating range for each process, the COD removal efficiency was in order of peroxi-electrocoagulation > peroxi-photoelectrocoagulation > photoelectrocoagulation>electrocoagulation. Finally, a kinetic study was carried out using the linear pseudo-second-order model and results showed that the pseudo-second-order equation provided the best correlation for the COD removal rate. Copyright © 2012 Elsevier B.V. All rights reserved.
Halocarbons as Halon Replacements. Volume 1. Technology Review and Initiation
1991-03-01
gases is usually accomplished by packed bed or plate-tower scrubbers . In some cases Venturi scrubbers are used for simultaneous removal of 95 TABLE 24...packed bed or plate-tower scrubbers to lower emissions to acceptable levels. When water is used as the scrubbing liquor, the blowdown stream is acidic...blowdown rates and makeup water. Because of these acidic conditions, the scrubber must be lined with an acid-resistant material. A highly basic
ERIC Educational Resources Information Center
Sierra Blas, Verónica
2015-01-01
The high rate of child mortality registered during the early months of the Civil War led the Republican authorities to initiate several operations to evacuate youngsters with the purpose of protecting and saving the children of Spain. At the beginning, the children were evacuated to zones in the interior of the country far removed from the front…
A rate-based transcutaneous CO2 sensor for noninvasive respiration monitoring.
Chatterjee, M; Ge, X; Kostov, Y; Luu, P; Tolosa, L; Woo, H; Viscardi, R; Falk, S; Potts, R; Rao, G
2015-05-01
The pain and risk of infection associated with invasive blood sampling for blood gas measurements necessitate the search for reliable noninvasive techniques. In this work we developed a novel rate-based noninvasive method for a safe and fast assessment of respiratory status. A small sampler was built to collect the gases diffusing out of the skin. It was connected to a CO2 sensor through gas-impermeable tubing. During a measurement, the CO2 initially present in the sampler was first removed by purging it with nitrogen. The gases in the system were then recirculated between the sampler and the CO2 sensor, and the CO2 diffusion rate into the sampler was measured. Because the measurement is based on the initial transcutaneous diffusion rate, reaching mass transfer equilibrium and heating the skin is no longer required, thus, making it much faster and safer than traditional method. A series of designed experiments were performed to analyze the effect of the measurement parameters such as sampler size, measurement location, subject positions, and movement. After the factor analysis tests, the prototype was sent to a level IV NICU for clinical trial. The results show that the measured initial rate of increase in CO2 partial pressure is linearly correlated with the corresponding arterial blood gas measurements. The new approach can be used as a trending tool, making frequent blood sampling unnecessary for respiratory status monitoring.
NASA Astrophysics Data System (ADS)
Romaidi; Hasanudin, Muhammad; Kholifah, Khusnul; Maulidiyah, Alik; Putro, Sapto P.; Kikuchi, Akira; Sakaguchi, Toshifumi
2018-05-01
The use of microalgae to produce biodiesel or possibly remove nutrients from industrial wastewater has gained important attention during recent years due to their photosynthetic rate and its versatile nature to grow in various wastewater systems. In this study, a microalgae, Scenedesmus sp., was cultured to enhance the lipid production and nutrients removal from tapioca wastewater sample. To assess lipid production, Scenedesmus sp. was cultured in different concentration of tapioca wastewater sample (from 0 to 100 %), and nutrient removal including BOD, COD, NH4, NO2, NO3 level by Scenedesmus sp. was assessed in 100% of tapioca wastewater culture. After 8 days of culture, it was found out that 50% of tapioca wastewater sample resulted in highest concentration of lipid content than that of the other concentrations. The level of environment indicator as nutrient removal such as BOD, COD, NH4, NO2, NO3 were also decreased up to 74%, 72%, 95%, 91%, and 91%, respectively. The pH condition changed from initial condition acidic (pH: 4) to neutral or basic condition (pH: 7-8) as recommended in wastewater treatment system. This research provided a novel approach and achieved efficient simultaneous lipid production and nutrients removal from tapioca wastewater sample by Scenedesmus’s culture system.
Walter, Daisy; Laleman, Wim; Jansen, Jeroen M; van Milligen de Wit, A W M; Weusten, Bas L; van Boeckel, Petra G; Hirdes, Meike M; Vleggaar, Frank P; Siersema, Peter D
2015-05-01
Self-expandable metal stents (SEMSs) are increasingly used for the treatment of benign biliary strictures (BBSs). A new fully covered SEMS (FCSEMS) with flared ends and high conformability was designed to prevent migration of the stent. To evaluate the efficacy of a novel FCSEMS with antimigration features. Prospective cohort study. Five hospitals in the Netherlands and Belgium. Consecutive patients with BBS. FCSEMS placement for 3 months. Initial and long term clinical success, stent migration rate and safety. Thirty-eight patients (24 men; mean age, 53 ± 16 years) were included. Stent placement was technically successful in 37 patients (97%). Two patients died of an unrelated cause before stent removal, and no data on these patients were available on stricture resolution. Initial clinical success was achieved in 28 of 35 patients (80%). During follow-up after stent removal, a symptomatic recurrent stricture developed in 6 of 28 patients (21%). Overall, the long-term clinical success rate was 63% (22 of 35 patients). Stent migration occurred in 11 of 35 patients (31%), including 5 symptomatic (14%) and 6 asymptomatic (17%) migrations. In total, 11 serious adverse events occurred in 10 patients (29%), with cholangitis (n = 5) being most common. Nonrandomized study design. Good initial clinical success was achieved after placement of this novel FCSEMS, but stricture recurrence was in the upper range compared with other FCSEMSs. The antimigration design could not prevent migration in a significant number of patients with a persisting stricture. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Space Operations Center, shuttle interaction study, volume 1
NASA Technical Reports Server (NTRS)
1981-01-01
The feasibility of the shuttle remote manipulator system (SRMS)-aided space operations center (SOC)/orbiter berthing was evaluated to determine: (1) whether the initial rates between the SOC and the orbiter can be removed by the arm; (2) what is the best strategy to be used; (3) whether the post-capture and maneuvering loads are within the capability of the SRMS; (4) can the SOC berthing port be brought in the immediate proximity of the orbiter berthing port; and (5) what is the best way to remove the residual relative motions. Various notational conventions are established and various important locations on the orbiter and SOC structures are defined. Reference frames are defined together with the mass properties of both the SOC and the orbiter.
Lin, Chong; Zhang, Wanhui; Yuan, Mengyang; Feng, Chunhua; Ren, Yuan; Wei, Chaohai
2014-09-01
Coking wastewater treatment plant (CWWTP) represents a typical point source of polycyclic aromatic hydrocarbons (PAHs) to the water environment and threatens the safety of drinking water in downstream regions. To enhance the removal of residual PAHs from bio-treated coking wastewater, a pilot-scale O3/ultraviolet (UV) fluidized bed reactor (O3/UV FBR) was designed and different operating factors including UV irradiation intensity, pH, initial concentration, contact time, and hydraulic retention time (HRT) were investigated at an ozone level of 240 g h(-1) and 25 ± 3 °C. A health risk evaluation and cost analysis were also carried out under the continuous-flow mode. As far as we know, this is the first time an O3/UV FBR has been explored for PAHs treatment. The results indicated that between 41 and 75 % of 18 target PAHs were removed in O3/UV FBR due to synergistic effects of UV irradiation. Both increased reaction time and increased pH were beneficial for the removal of PAHs. The degradation of the target PAHs within 8 h can be well fitted by the pseudo-first-order kinetics (R (2) > 0.920). The reaction rate was also positively correlated with the initial concentrations of PAHs. The health risk assessment showed that the total amount of carcinogenic substance exposure to surface water was reduced by 0.432 g day(-1). The economic analysis showed that the O3/UV FBR was able to remove 18 target PAHs at a cost of US$0.34 m(-3). These results suggest that O3/UV FBR is efficient in removing residuals from CWWTP, thus reducing the accumulation of persistent pollutant released to surface water.
Electrooxidation of industrial wastewater containing 1,4-dioxane in the presence of different salts.
Barndõk, H; Hermosilla, D; Cortijo, L; Torres, E; Blanco, A
2014-04-01
The treatment of 1,4-dioxane solution by electrochemical oxidation on boron-doped diamond was studied using a central composite design and the response surface methodology to investigate the use of SO4 (2-) and HCO3 (-) as supporting electrolytes considering the applied electric current, initial chemical oxygen demand (COD) value, and treatment time. Two industrial effluents containing bicarbonate alkalinity, one just carrying 1,4-dioxane (S1), and another one including 1,4-dioxane and 2-methyl-1,3-dioxolane (S2), were treated under optimized conditions and subsequently subjected to biodegradability assays with a Pseudomonas putida culture. Electrooxidation was compared with ozone oxidation (O3) and its combination with hydrogen peroxide (O3/H2O2). Regarding the experimental design, the optimal compromise for maximum COD removal at minimum energy consumption was shown at the maximum tested concentrations of SO4 (2-) and HCO3 (-) (41.6 and 32.8 mEq L(-1), respectively) and the maximum selected initial COD (750 mg L(-1)), applying a current density of 11.9 mA cm(-2) for 3.8 h. Up to 98 % of the COD was removed in the electrooxidation treatment of S1 effluent using 114 kWh per kg of removed COD and about 91 % of the COD from S2 wastewater applying 49 kWh per kg of removed COD. The optimal biodegradability enhancement was achieved after 1 h of electrooxidation treatment. In comparison with O3 and O3/H2O2 alternatives, electrochemical oxidation achieved the fastest degradation rate per oxidant consumption unit, and it also resulted to be the most economical treatment in terms of energy consumption and price per unit of removed COD.
2014-01-01
Background Low cost 2,4-Dichlorophenolyxacetic acid (2,4-D) widely used in controlling broad-leafed weeds is frequently detected in water resources. The main objectives of this research were focused on evaluating the feasibility of using granular activated carbon modified with acid to remove 2,4-D from aqueous phase, determining its removal efficiency and assessing the adsorption kinetics. Results The present study was conducted at bench-scale method. The influence of different pH (3–9), the effect of contact time (3–90 min), the amount of adsorbent (0.1-0.4 g), and herbicide initial concentration (0.5-3 ppm) on 2,4-D removal efficiency by the granular activated carbon were investigated. Based on the data obtained in the present study, pH of 3 and contact time of 60 min is optimal for 2,4-D removal. 2,4-D reduction rate increased rapidly by the addition of the adsorbent and decreased by herbicide initial concentration (63%). The percent of 2,4-D reduction were significantly enhanced by decreasing pH and increasing the contact time. The adsorption of 2,4-D onto the granular activated carbon conformed to Langmuir and Freundlich models, but was best fitted to type II Langmuir model (R2 = 0.999). The second order kinetics was the best for the adsorption of 2,4-D by modified granular activated carbon with R2 > 0.99. Regression analysis showed that all of the variables in the process have been statistically significant effect (p < 0.001). Conclusions In conclusion, granular activated carbon modified with acid is an appropriate method for reducing the herbicide in the polluted water resources. PMID:24410737
Dehghani, Mansooreh; Nasseri, Simin; Karamimanesh, Mojtaba
2014-01-10
Low cost 2,4-Dichlorophenolyxacetic acid (2,4-D) widely used in controlling broad-leafed weeds is frequently detected in water resources. The main objectives of this research were focused on evaluating the feasibility of using granular activated carbon modified with acid to remove 2,4-D from aqueous phase, determining its removal efficiency and assessing the adsorption kinetics. The present study was conducted at bench-scale method. The influence of different pH (3-9), the effect of contact time (3-90 min), the amount of adsorbent (0.1-0.4 g), and herbicide initial concentration (0.5-3 ppm) on 2,4-D removal efficiency by the granular activated carbon were investigated. Based on the data obtained in the present study, pH of 3 and contact time of 60 min is optimal for 2,4-D removal. 2,4-D reduction rate increased rapidly by the addition of the adsorbent and decreased by herbicide initial concentration (63%). The percent of 2,4-D reduction were significantly enhanced by decreasing pH and increasing the contact time. The adsorption of 2,4-D onto the granular activated carbon conformed to Langmuir and Freundlich models, but was best fitted to type II Langmuir model (R2 = 0.999). The second order kinetics was the best for the adsorption of 2,4-D by modified granular activated carbon with R2 > 0.99. Regression analysis showed that all of the variables in the process have been statistically significant effect (p < 0.001). In conclusion, granular activated carbon modified with acid is an appropriate method for reducing the herbicide in the polluted water resources.
29 CFR 417.13 - Initial decision of Administrative Law Judge.
Code of Federal Regulations, 2013 CFR
2013-07-01
... To Determine Adequacy of Constitution and Bylaws for Removal of Officers of Local Labor Organizations..., file an initial decision as to the adequacy of the constitution and bylaws for the purpose of removing...
29 CFR 417.13 - Initial decision of Administrative Law Judge.
Code of Federal Regulations, 2011 CFR
2011-07-01
... To Determine Adequacy of Constitution and Bylaws for Removal of Officers of Local Labor Organizations..., file an initial decision as to the adequacy of the constitution and bylaws for the purpose of removing...
29 CFR 417.13 - Initial decision of Administrative Law Judge.
Code of Federal Regulations, 2014 CFR
2014-07-01
... To Determine Adequacy of Constitution and Bylaws for Removal of Officers of Local Labor Organizations..., file an initial decision as to the adequacy of the constitution and bylaws for the purpose of removing...
29 CFR 417.13 - Initial decision of Administrative Law Judge.
Code of Federal Regulations, 2012 CFR
2012-07-01
... To Determine Adequacy of Constitution and Bylaws for Removal of Officers of Local Labor Organizations..., file an initial decision as to the adequacy of the constitution and bylaws for the purpose of removing...
Termites and large herbivores influence seed removal rates in an African savanna.
Acanakwo, Erik Francis; Sheil, Douglas; Moe, Stein R
2017-12-01
Seed removal can influence plant community dynamics, composition, and resulting vegetation characteristics. In the African savanna, termites and large herbivores influence vegetation in various ways, likely including indirect effects on seed predators and secondary dispersers. However, the intensity and variation of seed removal rates in African savannas has seldom been studied. We experimentally investigated whether termites and large herbivores were important factors in the mechanisms contributing to observed patterns in tree species composition on and off mounds, in Lake Mburo National Park, Uganda. Within fenced (excluding large herbivores) and unfenced termite mound and adjacent savanna plots, we placed seeds of nine native tree species within small open "cages," accessed by all animals, roofed cages that only allowed access to small vertebrates and invertebrates, and closed cages that permitted access by smaller invertebrates only (5 mm wire mesh). We found that mean seed removal rate was high (up to 87.3% per 3 d). Mound habitats experienced significantly higher removal rates than off-mound habitats. The mean removal rate of native seeds from closed cages was 11.1% per 3 d compared with 19.4% and 23.3% removed per 3 d in the roofed and open cages, respectively. Smaller seeds experienced higher removal rates than larger seeds. Large herbivore exclusion on mounds reduced native seed removal rates by a mean of 8.8% in the open cages, but increased removal rates by 1.7% in the open cages when off-mound habitats were fenced. While removal rates from open cages were higher on active mounds (30.9%) than on inactive mounds (26.7%), the removal rates from closed cages were lower on active vs. inactive mounds (6.1% vs. 11.6%, respectively). Thus, we conclude that large herbivores and Macrotermes mounds influence seed removal rates, though these effects appear indirect. © 2017 by the Ecological Society of America.
Lead paint removal with high-intensity light pulses.
Grapperhaus, Michael J; Schaefer, Raymond B
2006-12-15
This paper presents the results of an initial investigation into using high-intensity incoherent light pulses to strip paint. Measurements of light pulse characteristics, the reflectivity of different paints and initial experiments on the threshold for paint removal, and paint removal are presented, along with an approximate model consistent with experimental results. Paint removal tests include lead paint, the reduction of lead levels to below levels required for lead abatement, as well as air and light emissions measurements that are within regulatory guidelines.
Figueira, Paula; Henriques, Bruno; Teixeira, Ana; Lopes, Cláudia B; Reis, Ana T; Monteiro, Rui J R; Duarte, A C; Pardal, M A; Pereira, E
2016-06-01
The biosorption capability of two marine macroalgae (green Ulva lactuca and brown Fucus vesiculosus) was evaluated in the removal of toxic metals (Hg, Cd and Pb) from saline waters, under realistic conditions. Results showed that, independently of the contamination scenario tested, both macroalgae have a remarkable capacity to biosorb Hg and Pb. In single-contaminant systems, by using only c.a. 500 mg of non-pre-treated algae biomass (size <200 μm) per litter, it was possible to achieve removal efficiencies between 96 and 99 % for Hg and up to 86 % for Pb. Despite the higher removal of Hg, equilibrium was reached more quickly for Pb (after 8 h). In multi-contaminant systems, macroalgae exhibited a similar selectivity toward the target metals: Hg > Pb> > Cd, although Pb removal by U. lactuca was more inhibited than that achieved by F. vesiculosus. Under the experimental conditions used, none of the macroalgae was effective to remove Cd (maximum removal of 20 %). In all cases, the kinetics of biosorption was mathematically described with success. Globally, it became clear that the studied macroalgae may be part of simple, efficient, and cost-effective water treatment technologies. Nevertheless, Fucus vesiculosus has greater potential, since it always presented higher initial sorption rates and higher removal efficiencies.
Silica removal in industrial effluents with high silica content and low hardness.
Latour, Isabel; Miranda, Ruben; Blanco, Angeles
2014-01-01
High silica content of de-inked paper mill effluents is limiting their regeneration and reuse after membrane treatments such as reverse osmosis (RO). Silica removal during softening processes is a common treatment; however, the effluent from the paper mill studied has a low hardness content, which makes the addition of magnesium compounds necessary to increase silica removal. Two soluble magnesium compounds (MgCl₂∙6H₂O and MgSO₄∙7H₂O) were tested at five dosages (250-1,500 mg/L) and different initial pH values. High removal rates (80-90%) were obtained with both products at the highest pH tested (11.5). With these removal efficiencies, it is possible to work at high RO recoveries (75-85%) without silica scaling. Although pH regulation significantly increased the conductivity of the waters (at pH 11.5 from 2.1 to 3.7-4.0 mS/cm), this could be partially solved by using Ca(OH)₂ instead of NaOH as pH regulator (final conductivity around 3.0 mS/cm). Maximum chemical oxygen demand (COD) removal obtained with caustic soda was lower than with lime (15 vs. 30%). Additionally, the combined use of a polyaluminum coagulant during the softening process was studied; the coagulant, however, did not significantly improve silica removal, obtaining a maximum increase of only 10%.
Ryu, Byung-Gon; Kim, Jungmin; Han, Jong-In; Yang, Ji-Won
2017-02-01
This study examined the feasibility of using an algal-bacterial process for removal of phenol and NH 4 + -N from differently diluted coke wastewater with simultaneous production of biomass. Under illumination, microalgal-bacterial (MSB) cultures performed complete phenol degradation at all dilutions of coke wastewater while sole microalgal culture (MSA) degraded a maximum of 27.3% of phenol (initial concentration: 24.0mgL -1 ) from 5-fold diluted wastewater. Furthermore, the MSB culture had the highest rate of NH 4 + -N removal (8.3mgL -1 d -1 ) and fatty acid production (20mgL -1 d -1 ) which were 2.3- and 1.5-fold higher than those observed in the MSA cultures, probably due to decreases in toxic organic pollutants. Multivariate analyses indicated that co-cultivation of activated sludge was directly correlated with the elevated removals of phenol and NH 4 + -N. In the presence of sludge, adequate dilution of the coke wastewater can maximize the effect of bacteria on NH 4 + -N removal and biomass production. Copyright © 2016 Elsevier Ltd. All rights reserved.
Polyrhodanine modified anodic aluminum oxide membrane for heavy metal ions removal.
Song, Jooyoung; Oh, Hyuntaek; Kong, Hyeyoung; Jang, Jyongsik
2011-03-15
Polyrhodanine was immobilized onto the inner surface of anodic aluminum oxide (AAO) membrane via vapor deposition polymerization method. The polyrhodanine modified membrane was applied to remove heavy metal ions from aqueous solution because polyrhodanine could be coordinated with specific metal ions. Several parameters such as initial metal concentration, contact time and metal species were evaluated systematically for uptake efficiencies of the fabricated membrane under continuous flow condition. Adsorption isotherms of Hg(II) ion on the AAO-polyrhodanine membrane were analyzed with Langmuir and Freundlich isotherm models. The adsorption rate of Hg(II) ion on the membrane was obeyed by a pseudo-second order equation, indicating the chemical adsorption. The maximum removal capacity of Hg(II) ion onto the fabricated membrane was measured to be 4.2 mmol/g polymer. The AAO-polyrhodanine membrane had also remarkable uptake performance toward Ag(I) and Pb(II) ions. Furthermore, the polyrhodanine modified membrane could be recycled after recovery process. These results demonstrated that the polyrhodanine modified AAO membrane provided potential applications for removing the hazardous heavy metal ions from wastewater. Copyright © 2011 Elsevier B.V. All rights reserved.
Aydin, Senar
2016-12-01
The aim of this study was to investigate the usability of magnetic Fe3O4/red mud nanoparticles (NPs) for the removal of organophosphorus pesticides from water samples. The effect of various experimental parameters such as red mud amount in Fe3O4/red mud-NPs, pH, contact time, initial pesticide concentrations and adsorbent dose was studied in order to find the optimum conditions for their removal in a batch process. The Fe3O4/red mud-NPs were characterized by using TGA, SEM, XRD, VSM, and determination of the BET surface area. After the regenerated Fe3O4/red mud-NPs were used three times, the sorption capacity and the magnetic separability were observed to be unaffected. Freundlich model described the sorption process better than Langmuir isotherm and the pseudo second-order kinetic model was determined as the best-fit model. The film diffusion mechanism was found to be a main rate control mechanism. The Fe3O4/red mud-NPs satisfactorily removed the OPPS from real water samples.
Use of laterite for the removal of fluoride from contaminated drinking water.
Sarkar, Mitali; Banerjee, Aparna; Pramanick, Partha Pratim; Sarkar, Asit R
2006-10-15
The effects of different operational variables on the mechanistic function of laterite in removal of fluoride have been investigated. Thermodynamic parameters such as free energy change, enthalpy, and entropy of the process, as well as the sorption isotherm, were evaluated. The extent of solute removal is determined by initial solute concentration, operational conditions, laterite dose, and solution pH. For a fixed set of experimental conditions, a model equation is developed from which the percent removal corresponding to each load of fluoride is determined. The mechanism of fluoride adsorption is governed by the zero point charge of laterite and follows a first-order rate equation. pH has a vital role influencing the surface characteristics of laterite. To simulate the flow dynamics, fluoride solution was run through a fixed bed column. The pattern of breakthrough curves for different influent fluoride concentration, pH, and column bed height was characterized. The column efficiency was tested from the bed depth-service time model. The elution of the retained fluoride was studied and the effectiveness of column operation was determined by the retention-elution cycles.
NASA Astrophysics Data System (ADS)
Misran, E.; Bani, O.; Situmeang, E. M.; Purba, A. S.
2018-02-01
The effort to remove methylene blue in artificial solution had been conducted using adsorption process. The abundant banana stem waste was utilized as activated carbon precursor. This study aimed to analyse the influence of solution pH to removal efficiency of methylene blue using activated carbon from banana stem as adsorbent. Activated carbon from banana stem was obtained by chemical activation using H3PO4 solution. Proximate analysis result showed that the activated carbon has 47.22% of fixed carbon. This value exhibited that banana stem was a potential adsorbent precursor. Methylene blue solutions were prepared at initial concentration of 50 ppm. The influence of solution pH was investigated with the use of 0.2 g adsorbent for 100 mL dye solution. The adsorption was conducted using shaker with at a constant rate of 100 rpm at room temperature for 90 minutes. The results showed that solution pH influenced the adsorption. The activated carbon from banana stem demonstrated satisfying performance since removal efficiencies of methylene blue were higher than 99%.
Falandysz, Jerzy; Drewnowska, Małgorzata
2017-05-01
Mushrooms (Cantharellus cibarius and Amanita fulva) were blanched (parboiled) and pickled using different treatment conditions with the aim of carrying out the study into effect on removal of toxic mercury (Hg) accumulated in flesh. Blanching of fresh sliced C. cibarius caused leaching of Hg by approximately 15%, while loss of up to 35% was observed for sliced, deep-frozen fruit bodies. The rate of Hg leaching from the C. cibarius in practice was the same when blanched for 5 or 15 min irrespective of potable or deionized water used. Pickling of blanched C. cibarius with a diluted vinegar marinade had only a minor, if any, effect on removal of Hg and was without effect on blanched caps of A. fulva. Mercury was better extracted by boiling water from the fresh caps of A. fulva (56 ± 2% of the initial level in fresh caps) than from the fresh or frozen fruit bodies of C. cibarius. Total leaching rate of Hg from a pickled C. cibarius when fresh fruit bodies were processed was between 15 ± 5 and 37 ± 7% (median range 13-34%), and when deep-frozen fruit bodies were processed, it was between 37 ± 7 and 39 ± 8% (median range 34-39%). Pickling of the caps of A. fulva with diluted vinegar did not increase leaching of Hg. Blanching of mushrooms before future culinary use is a simple procedure recommended in reduction of contamination with Hg of cooked mushroom meal. Pickling had little if any effect on further removal of Hg from the initially blanched mushrooms.
Ochoa-Chavez, A S; Pieczyńska, A; Fiszka Borzyszkowska, A; Espinoza-Montero, P J; Siedlecka, E M
2018-06-01
In this study, the electrochemical degradation process of 5-fluorouracil (5-FU) in aqueous media was performed using a continuous flow reactor in an undivided cell (system I), and in a divided cell with a cationic membrane (Nafion ® 424) (system II). In system I, 75% of 5-FU degradation was achieved (50 mg L -1 ) with a applied current density j app = 150 A m -2 , volumetric flow rate qv = 13 L h -1 , after 6 h of electrolysis (k app = 0.004 min -1 ). The removal efficiency of 5-FU was higher (95%) when the concentration was 5 mg L -1 under the same conditions. Nitrates (22% of initial amount of N), fluorides (27%) and ammonium (10%) were quantified after 6 h of electrolysis. System II, 77% of 5-FU degradation was achieved (50 mg L -1 ) after 6 h of electrolysis (k app = 0.004 min -1 ). The degradation rate of 5-FU was complete when the concentration was 5 mg L -1 under the same conditions. Nitrates (29% of initial amount of N), fluorides (25%) and ammonium (5%) were quantified after 6 h of electrolysis. In addition, the main organic byproducts identified by mass spectroscopy were aliphatic compound with carbonyl and carboxyl functionalities. Due to, the mineralization of 5-FU with acceptable efficiency of 88% found in system II (j app of 200 A m -2 ), this system seems to be more promising in the cytostatic drug removal. Moreover the efficiency of 5-FU removal in diluted solutions is better in system II than in system I. Copyright © 2018 Elsevier Ltd. All rights reserved.
Removal of corallivorous snails as a proactive tool for the conservation of acroporid corals
Miller, Margaret W.; Bright, Allan J.; Cameron, Caitlin M.
2014-01-01
Corallivorous snail feeding is a common source of tissue loss for the threatened coral, Acropora palmata, accounting for roughly one-quarter of tissue loss in monitored study plots over seven years. In contrast with larger threats such as bleaching, disease, or storms, corallivory by Coralliophila abbreviata is one of the few direct sources of partial mortality that may be locally managed. We conducted a field experiment to explore the effectiveness and feasibility of snail removal. Long-term monitoring plots on six reefs in the upper Florida Keys were assigned to one of three removal treatments: (1) removal from A. palmata only, (2) removal from all host coral species, or (3) no-removal controls. During the initial removal in June 2011, 436 snails were removed from twelve 150 m2 plots. Snails were removed three additional times during a seven month “removal phase”, then counted at five surveys over the next 19 months to track recolonization. At the conclusion, snails were collected, measured and sexed. Before-After-Control-Impact analysis revealed that both snail abundance and feeding scar prevalence were reduced in removal treatments compared to the control, but there was no difference between removal treatments. Recolonization by snails to baseline abundance is estimated to be 3.7 years and did not differ between removal treatments. Recolonization rate was significantly correlated with baseline snail abundance. Maximum snail size decreased from 47.0 mm to 34.6 mm in the removal treatments. The effort required to remove snails from A. palmata was 30 diver minutes per 150 m2 plot, compared with 51 min to remove snails from all host corals. Since there was no additional benefit observed with removing snails from all host species, removals can be more efficiently focused on only A. palmata colonies and in areas where C. abbreviata abundance is high, to effectively conserve A. palmata in targeted areas. PMID:25469321
NASA Technical Reports Server (NTRS)
Stella, P. M.
1984-01-01
The availability of data regarding the radiation behavior of GaAs and silicon solar cells is discussed as well as efforts to provide sufficient information. Other materials are considered too immature for reasonable radiation evaluation. The lack of concern over the possible catastrophic radiation degradation in cascade cells is a potentially serious problem. Lithium counterdoping shows potential for removing damage in irradiated P-type material, although initial efficiencies are not comparable to current state of the art. The possibility of refining the lithium doping method to maintain high initial efficiencies and combining it with radiation tolerant structures such as thin BSF cells or vertical junction cells could provide a substantial improvement in EOL efficiencies. Laser annealing of junctions, either those formed ion implantation or diffusion, may not only improve initial cell performance but might also reduce the radiation degradation rate.
Chen, Hao; Gurmesa, Geshere A.; Liu, Lei; Zhang, Tao; Fu, Shenglei; Liu, Zhanfeng; Dong, Shaofeng; Ma, Chuan; Mo, Jiangming
2014-01-01
Global changes such as increasing CO2, rising temperature, and land-use change are likely to drive shifts in litter inputs to forest floors, but the effects of such changes on litter decomposition remain largely unknown. We initiated a litter manipulation experiment to test the response of litter decomposition to litter removal/addition in three successional forests in southern China, namely masson pine forest (MPF), mixed coniferous and broadleaved forest (MF) and monsoon evergreen broadleaved forest (MEBF). Results showed that litter removal decreased litter decomposition rates by 27%, 10% and 8% and litter addition increased litter decomposition rates by 55%, 36% and 14% in MEBF, MF and MPF, respectively. The magnitudes of changes in litter decomposition were more significant in MEBF forest and less significant in MF, but not significant in MPF. Our results suggest that change in litter quantity can affect litter decomposition, and this impact may become stronger with forest succession in tropical forest ecosystem. PMID:24901698
Senthilkumaar, S; Kalaamani, P; Porkodi, K; Varadarajan, P R; Subburaam, C V
2006-09-01
The adsorption of Reactive red dye (RR) onto Coconut tree flower carbon (CFC) and Jute fibre carbon (JFC) from aqueous solution was investigated. Adsorption studies were carried out at different initial dye concentrations, initial solution pH and adsorbent doses. The kinetic studies were also conducted; the adsorption of Reactive red onto CFC and JFC followed pseudosecond-order rate equation. The effective diffusion coefficient was evaluated to establish the film diffusion mechanism. Quantitative removal of Reactive red dye was achieved at strongly acidic conditions for both the carbons studied. The adsorption isotherm data were fitted well to Langmuir isotherm and the adsorption capacity were found to be 181.9 and 200 mg/g for CFC and JFC, respectively. The overall rate of dye adsorption appeared to be controlled by chemisorption, in this case in accordance with poor desorption studies.
Method of CO.sub.2 removal from a gasesous stream at reduced temperature
Fisher, James C; Siriwardane, Ranjani V; Berry, David A; Richards, George A
2014-11-18
A method for the removal of H.sub.2O and CO.sub.2 from a gaseous stream comprising H.sub.2O and CO.sub.2, such as a flue gas. The method initially utilizes an H.sub.2O removal sorbent to remove some portion of the H.sub.2O, producing a dry gaseous stream and a wet H.sub.2O removal sorbent. The dry gaseous stream is subsequently contacted with a CO.sub.2 removal sorbent to remove some portion of the CO.sub.2, generating a dry CO.sub.2 reduced stream and a loaded CO.sub.2 removal sorbent. The loaded CO.sub.2 removal sorbent is subsequently heated to produce a heated CO.sub.2 stream. The wet H.sub.2O removal sorbent and the dry CO.sub.2 reduced stream are contacted in a first regeneration stage, generating a partially regenerated H.sub.2O removal sorbent, and the partially regenerated H.sub.2O removal sorbent and the heated CO.sub.2 stream are subsequently contacted in a second regeneration stage. The first and second stage regeneration typically act to retain an initial monolayer of moisture on the various removal sorbents and only remove moisture layers bound to the initial monolayer, allowing for relatively low temperature and pressure operation. Generally the applicable H.sub.2O sorption/desorption processes may be conducted at temperatures less than about 70.degree. C. and pressures less than 1.5 atmospheres, with certain operations conducted at temperatures less than about 50.degree. C.
Essam, Tamer; Aly Amin, Magdy; El Tayeb, Ossama; Mattiasson, Bo; Guieysse, Benoit
2007-04-01
Simulated solar UV/TiO(2) photocatalysis was efficient to detoxify a mixture of 100 mgphenoll(-1) and 50 mgp-nitrophenol (PNP) l(-1) and allow the subsequent biodegradation of the remaining pollutants and their photocatalytic products under photosynthetic aeration with Chlorella vulgaris. Photocatalytic degradation of phenol and PNP was well described by pseudo-first order kinetics (r(2)>0.98) with removal rate constants of 1.9x10(-4) and 2.8x10(-4)min(-1), respectively, when the pollutants were provided together and 5.7x10(-4) and 9.7x10(-4)min(-1), respectively, when they were provided individually. Photocatalytic pre-treatment of the mixture during 60 h removed 50+/-1% and 62+/-2% of the phenol and PNP initially present but only 11+/-3% of the initial COD. Hydroquinone, nitrate and catechol were identified as PNP photocatalytic products and catechol and hydroquinone as phenol photocatalytic products. Subsequent biological treatment of the pre-treated samples removed the remaining contaminants and their photocatalytic products as well as 81-83% of the initial COD, allowing complete detoxification of the mixture to C. vulgaris. Similar detoxification efficiencies were recorded after biological treatment of the irradiated mixture with activated sludge microflora or with an acclimated consortia composed of a phenol-degrading Alcaligenes sp. and a PNP-degrading Arthrobacter sp., although the acclimated strains biodegraded the remaining pollutants faster. Biological treatment of the non-irradiated mixture was inefficient due to C. vulgaris inhibition.
Effect of time on dyeing wastewater treatment
NASA Astrophysics Data System (ADS)
Ye, Tingjin; Chen, Xin; Xu, Zizhen; Chen, Xiaogang; Shi, Liang; He, Lingfeng; Zhang, Yongli
2018-03-01
The preparation of carboxymethylchitosan wrapping fly-ash adsorbent using high temperature activated fly ash and sodium carboxymethyl chitosan (CWF), as with the iron-carbon micro-electrolysis process simulation and actual printing and dyeing wastewater. The effects of mixing time and static time on decolorization ratio, COD removing rate and turbidness removing rate were investigated. The experimental results show that the wastewater stirring times on the decolorization rate and COD removal rate and turbidity removal rate influence, with increasing of the stirring time, three showed a downward trend, and reached the peak at 10 min time; wastewater time on the decolorization ratio and COD removing efficiency and turbidness removing rate influence, along with standing time increase, three who declined and reached the maximum in 30min time.
Cohen, Rebecca; Sheeder, Jeanelle; Arango, Natalia; Teal, Stephanie B; Tocce, Kristina
2016-02-01
To compare discontinuation rates and incidence of repeat pregnancy within 1 year among young mothers choosing postplacental intrauterine devices (IUDs) versus postpartum contraceptive implants. We enrolled a prospective cohort of postpartum adolescents and young women who chose either postplacental IUDs or postpartum contraceptive implants prior to hospital discharge. We used chart review and phone interviews to assess device discontinuation (by request or expulsion) and pregnancy within 12 months. Of the 244 13-22 year-old participants, 82 chose IUDs (74 levonorgestrel IUDs and 8 copper IUDs), and 162 chose implants. Both groups had participant-requested discontinuation rates of 14% (9/67 IUD; 19/135 implant) within 1 year. Participants choosing IUDs had a 25% (17/67) expulsion rate. Median time to expulsion was 4.1 weeks (range: 0.4-29.3 weeks, 16/17 within 12 weeks), and participants recognized 15/17 expulsions. IUD initiators had significantly higher pregnancy rates by 12 months (7.6% vs. 1.5%, p=0.04). Most pregnancies occurred when women discontinued their initial device and did not start alternative contraception. Participant-requested discontinuation was similar in both groups. Differences in overall device discontinuation rates were due to IUD expulsions. Pregnancy rates by 12 months postpartum were lower than previously reported in this age group in both implant initiators and IUD initiators. Young mothers who choose postplacental IUDs or postpartum contraceptive implants are unlikely to request removal within the first year. Clinicians should counsel postplacental IUD users that early expulsion is common (25%) and may be unrecognized (11% of expulsions). Patients should have a plan for contraceptive management should expulsion occur. Copyright © 2016 Elsevier Inc. All rights reserved.
Sandhwar, Vishal Kumar; Prasad, Basheshwar
2017-12-01
In this work, comparative study between electrochemical processes such as electrocoagulation (EC), peroxi-coagulation (PC) and peroxi-electrocoagulation (PEC) was performed for the removal of phthalic acid (PA) and chemical oxygen demand (COD) from aqueous medium. Initially, acid treatment was studied at various pH (1-3) and temperature (10-55 °C). Subsequently, the supernatant was re-treated by electrochemical processes such as EC, PC and PEC separately. Independent parameters viz. pH, current density (CD), electrolyte concentration (m), electrode gap (g), H 2 O 2 concentration and electrolysis time (t) were optimized by Central Composite Design (CCD) for these electrochemical processes. All three processes were compared based on removal, energy consumption, kinetic analysis, operating cost and sludge characteristics. In this study, PEC process was found more efficient among EC, PC and PEC processes in order to get maximum removal, minimum energy consumption and minimum operating cost. Maximum removal of PA- 68.21%, 74.36%, 82.25% & COD- 64.79%, 68.15%, 75.21% with energy consumption - 120.95, 97.51, 65.68 (kWh/kg COD removed) were attained through EC, PC and PEC processes respectively at their corresponding optimum conditions. Results indicated that PA and COD removals are in order of PEC > PC > EC under optimum conditions. First order kinetic model was found able to describe the degradation kinetics and provided best correlation for the removal rate within the acceptable error range. Copyright © 2017 Elsevier Ltd. All rights reserved.
Removal of acetaminophen in water by laccase immobilized in barium alginate.
Ratanapongleka, Karnika; Punbut, Supot
2018-02-01
This research has focused on the optimization of immobilized laccase condition and utilization in degradation of acetaminophen contaminated in aqueous solution. Laccase from Lentinus polychrous was immobilized in barium alginate. The effects of laccase immobilization such as sodium alginate concentration, barium chloride concentration and gelation time were studied. The optimal conditions for immobilization were sodium alginate 5% (w/v), barium chloride 5% (w/v) and gelation time of 60 min. Immobilized laccase was then used for acetaminophen removal. Acetaminophen was removed quickly in the first 50 min. The degradation rate and percentage of removal increased when the enzyme concentration increased. Immobilized laccase at 0.57 U/g-alginate showed the maximum removal at 94% in 240 min. The removal efficiency decreased with increasing initial acetaminophen concentration. The K m value for immobilized laccase (98.86 µM) was lower than that of free laccase (203.56 µM), indicating that substrate affinity was probably enhanced by immobilization. The immobilized enzyme exhibited high activity and good acetaminophen removal at pH 7 and temperature of 35°C. The activation energies of free and immobilized laccase for degradation of acetaminophen were 8.08 and 17.70 kJ/mol, respectively. It was also found that laccase stability to pH and temperature increased after immobilization. Furthermore, immobilized laccase could be reused for five cycles. The capability of removal and enzyme activity were retained above 70%.
NASA Astrophysics Data System (ADS)
Rouhnia, Mohamad; Strom, Kyle
2015-09-01
We experimentally examine sedimentation from a freshwater suspension of clay flocs overlying saltwater in the presence of gravitational instabilities. The study seeks to determine: (1) if flocculation hampers or alters interface instability formation; (2) how the removal rates of sediment from the buoyant layer compare to those predicted by individual floc settling; and (3) whether or not it is possible to develop a model for effective settling velocity. The experiments were conducted in a tank at isothermal conditions. All experiments were initially stably stratified but later developed instabilities near the interface that grew into downward convecting plumes of fluid and sediment. Throughout, we measured sediment concentration in the upper and lower layers, floc size, and plume descent rates. The data showed that flocculation modifies the mixture settling velocity, and therefore shifts the mode of interface instability from double-diffusive (what one would expect from unflocculated clay) to settling-driven leaking and Rayleigh-Taylor instability formation. Removal rates of sediment from the upper layer in the presence of these instabilities were on the same order of magnitude as those predicted by individual floc settling. However, removal rates were found to better correlate with the speed of the interface plumes. A simple force-balance model was found to be capable of reasonably describing plume velocity based on concentration in the buoyant layer. This relation, coupled with a critical Grashof number and geometry relations, allowed us to develop a model for the effective settling velocity of the mixture based solely on integral values of the upper layer.
Shah, G M; Winer, R L; Cutler, R E; Arieff, A I; Goodman, W G; Lacher, J W; Schoenfeld, P Y; Coburn, J W; Horowitz, A M
1987-10-01
While the use of magnesium-containing compounds is usually contraindicated in dialysis patients, the risk of toxicity from hypermagnesemia can be reduced by lowering the magnesium concentration in dialysate. We examined the effects of a magnesium-free dialysate on both serum magnesium level and the peritoneal removal rate of magnesium over 12 weeks in 25 stable patients undergoing continuous ambulatory peritoneal dialysis (CAPD). After 2 weeks, the serum magnesium level decreased from 2.2 to 1.9 mg/dL (0.9 to 0.8 mmol/L) (P less than .02) and the peritoneal removal rate increased from 66 to 83 mg/d (2.8 to 3.5 mmol/d) (P less than .05), with both values remaining stable thereafter. There was a strong association between these parameters (r = -0.62, P less than .05), suggesting that the serum magnesium level decreased as a result of the initial increased peritoneal removal rate. For an additional 4-week period, a subgroup of nine patients received magnesium-containing, phosphate binding agents instead of those containing only aluminum. During this phase, serum inorganic phosphorus was well controlled. The serum magnesium level increased only from 1.8 to 2.5 mg/dL (0.7 to 1.0 mmol/L) (P less than .05), due in great part to the concomitant 41% rise in peritoneal magnesium removal from 91 to 128 mg/d (3.8 to 5.3 mmol/d) (P less than .05). No toxicity was noted during the entire 16-week study period, nor did serum calcium change. Thus, serum magnesium levels remained within an acceptable range as magnesium-containing phosphate binders were given through the use of magnesium-free peritoneal dialysate.(ABSTRACT TRUNCATED AT 250 WORDS)
Harris, S.H.; Smith, R.L.
2009-01-01
Nitrification and nitrate reduction were examined in an ephemeral drainage channel receiving discharge from coalbed natural gas (CBNG) production wells in the Powder River Basin, Wyoming. CBNG co-produced water typically contains dissolved inorganic nitrogen (DIN), primarily as ammonium. In this study, a substantial portion of discharged ammonium was oxidized within 50??m of downstream transport, but speciation was markedly influenced by diel fluctuations in dissolved oxygen (> 300????M). After 300??m of transport, 60% of the initial DIN load had been removed. The effect of benthic nitrogen-cycling processes on stream water chemistry was assessed at 2 locations within the stream channel using acrylic chambers to conduct short-term (2-6??h), in-stream incubations. The highest ambient DIN removal rates (2103????mol N m- 2 h- 1) were found at a location where ammonium concentrations > 350????M. This occurred during light incubations when oxygen concentrations were highest. Nitrification was occurring at the site, however, net accumulation of nitrate and nitrite accounted for < 12% of the ammonium consumed, indicating that other ammonium-consuming processes were also occurring. In dark incubations, nitrite and nitrate consumption were dominant processes, while ammonium was produced rather than consumed. At a downstream location nitrification was not a factor and changes in DIN removal rates were controlled by nitrate reduction, diel fluctuations in oxygen concentration, and availability of electron donor. This study indicates that short-term adaptation of stream channel processes can be effective for removing CBNG DIN loads given sufficient travel distances, but the long-term potential for nitrogen remobilization and nitrogen saturation remain to be determined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guardia, A. de, E-mail: amaury.de-guardia@cemagref.f; Universite Europeenne de Bretagne, F-35000 Rennes; Mallard, P.
This paper aimed to compare household waste, separated pig solids, food waste, pig slaughterhouse sludge and green algae regarding processes ruling nitrogen dynamic during composting. For each waste, three composting simulations were performed in parallel in three similar reactors (300 L), each one under a constant aeration rate. The aeration flows applied were comprised between 100 and 1100 L/h. The initial waste and the compost were characterized through the measurements of their contents in dry matter, total carbon, Kjeldahl and total ammoniacal nitrogen, nitrite and nitrate. Kjeldahl and total ammoniacal nitrogen and nitrite and nitrate were measured in leachates andmore » in condensates too. Ammonia and nitrous oxide emissions were monitored in continue. The cumulated emissions in ammonia and in nitrous oxide were given for each waste and at each aeration rate. The paper focused on process of ammonification and on transformations and transfer of total ammoniacal nitrogen. The parameters of nitrous oxide emissions were not investigated. The removal rate of total Kjeldahl nitrogen was shown being closely tied to the ammonification rate. Ammonification was modelled thanks to the calculation of the ratio of biodegradable carbon to organic nitrogen content of the biodegradable fraction. The wastes were shown to differ significantly regarding their ammonification ability. Nitrogen balances were calculated by subtracting nitrogen losses from nitrogen removed from material. Defaults in nitrogen balances were assumed to correspond to conversion of nitrate even nitrite into molecular nitrogen and then to the previous conversion by nitrification of total ammoniacal nitrogen. The pool of total ammoniacal nitrogen, i.e. total ammoniacal nitrogen initially contained in waste plus total ammoniacal nitrogen released by ammonification, was calculated for each experiment. Then, this pool was used as the referring amount in the calculation of the rates of accumulation, stripping and nitrification of total ammoniacal nitrogen. Separated pig solids were characterised by a high ability to accumulate total ammoniacal nitrogen. Whatever the waste, the striping rate depended mostly on the aeration rate and on the pool concentration in biofilm. The nitrification rate was observed as all the higher as the concentration in total ammoniacal nitrogen in the initial waste was low. Thus, household waste and green algae exhibited the highest nitrification rates. This result could mean that in case of low concentrations in total ammoniacal nitrogen, a nitrifying biomass was already developed and that this biomass consumed it. In contrast, in case of high concentrations, this could traduce some difficulties for nitrifying microorganisms to develop.« less
Arsenic uptake by Lemna minor in hydroponic system.
Goswami, Chandrima; Majumder, Arunabha; Misra, Amal Kanti; Bandyopadhyay, Kaushik
2014-01-01
Arsenic is hazardous and causes several ill effects on human beings. Phytoremediation is the use of aquatic plants for the removal of toxic pollutants from external media. In the present research work, the removal efficiency as well as the arsenic uptake capacity of duckweed Lemna minor has been studied. Arsenic concentration in water samples and plant biomass were determined by AAS. The relative growth factor of Lemna minor was determined. The duckweed had potential to remove as well as uptake arsenic from the aqueous medium. Maximum removal of more than 70% arsenic was achieved atinitial concentration of 0.5 mg/1 arsenic on 15th day of experimental period of 22 days. Removal percentage was found to decrease with the increase in initial concentration. From BCF value, Lemna minor was found to be a hyperaccumulator of arsenic at initial concentration of 0.5 mg/L, such that accumulation decreased with increase in initial arsenic concentration.
Assavasilavasukul, Prapakorn; Lau, Boris L T; Harrington, Gregory W; Hoffman, Rebecca M; Borchardt, Mark A
2008-05-01
The presence of waterborne enteric pathogens in municipal water supplies contributes risk to public health. To evaluate the removal of these pathogens in drinking water treatment processes, previous researchers have spiked raw waters with up to 10(6) pathogens/L in order to reliably detect the pathogens in treated water. These spike doses are 6-8 orders of magnitude higher than pathogen concentrations routinely observed in practice. In the present study, experiments were conducted with different sampling methods (i.e., grab versus continuous sampling) and initial pathogen concentrations ranging from 10(1) to 10(6) pathogens/L. Results showed that Cryptosporidium oocyst and Giardia cyst removal across conventional treatment were dependent on initial pathogen concentrations, with lower pathogen removals observed when lower initial pathogen spike doses were used. In addition, higher raw water turbidity appeared to result in higher log removal for both Cryptosporidium oocysts and Giardia cysts.
Liu, Fenwu; Zhou, Jun; Zhang, Shasha; Liu, Lanlan; Zhou, Lixiang; Fan, Wenhua
2015-01-01
Schwertmannite-mediated removal of arsenic from contaminated water has attracted increasing attention. However, schwertmannite chemical synthesis behavior under different H2O2 supply rates for ferrous ions oxidation is unclear. This study investigated pH, ferrous ions oxidation efficiency, and total iron precipitation efficiency during schwertmannite synthesis by adding H2O2 into FeSO4 · 7H2O solution at different supply rates. Specific surface area and arsenic (III) removal capacity of schwertmannite have also been studied. Results showed that pH decreased from ~3.48 to ~1.96, ~2.06, ~2.12, ~2.14, or ~2.17 after 60 h reaction when the ferrous ions solution received the following corresponding amounts of H2O2: 1.80 mL at 2 h (treatment 1); 0.90 mL at 2 h and 14 h (treatment 2); 0.60 mL at 2, 14, and 26 h (treatment 3); 0.45 mL at 2, 14, 26, and 38 h (treatment 4), or 0.36 mL at 2, 14, 26, 38, and 50 h (treatment 5). Slow H2O2 supply significantly inhibited the total iron precipitation efficiency but improved the specific surface area or arsenic (III) removal capacity of schwertmannite. For the initial 50.0 μg/L arsenic (III)-contaminated water under pH ~7.0 and using 0.25 g/L schwertmannite as an adsorbent, the total iron precipitation efficiency, specific surface area of the harvested schwertmannite, and schwertmannite arsenic(III) removal efficiency were 29.3%, 2.06 m2/g, and 81.1%, respectively, in treatment 1. However, the above parameters correspondingly changed to 17.3%, 16.30 m2/g, and 96.5%, respectively, in treatment 5.
Jena, Jyotsnarani; Kumar, Ravindra; Dixit, Anshuman; Pandey, Sony; Das, Trupti
2015-01-01
Simultaneous nitrate-N, phosphate and COD removal was evaluated from synthetic waste water using mixed microbial consortia in an anoxic environment under various initial carbon load (ICL) in a batch scale reactor system. Within 6 hours of incubation, enriched DNPAOs (Denitrifying Polyphosphate Accumulating Microorganisms) were able to remove maximum COD (87%) at 2g/L of ICL whereas maximum nitrate-N (97%) and phosphate (87%) removal along with PHB accumulation (49 mg/L) was achieved at 8 g/L of ICL. Exhaustion of nitrate-N, beyond 6 hours of incubation, had a detrimental effect on COD and phosphate removal rate. Fresh supply of nitrate-N to the reaction medium, beyond 6 hours, helped revive the removal rates of both COD and phosphate. Therefore, it was apparent that in spite of a high carbon load, maximum COD and nutrient removal can be maintained, with adequate nitrate-N availability. Denitrifying condition in the medium was evident from an increasing pH trend. PHB accumulation by the mixed culture was directly proportional to ICL; however the time taken for accumulation at higher ICL was more. Unlike conventional EBPR, PHB depletion did not support phosphate accumulation in this case. The unique aspect of all the batch studies were PHB accumulation was observed along with phosphate uptake and nitrate reduction under anoxic conditions. Bioinformatics analysis followed by pyrosequencing of the mixed culture DNA from the seed sludge revealed the dominance of denitrifying population, such as Corynebacterium, Rhodocyclus and Paraccocus (Alphaproteobacteria and Betaproteobacteria). Rarefaction curve indicated complete bacterial population and corresponding number of OTUs through sequence analysis. Chao1 and Shannon index (H’) was used to study the diversity of sampling. “UCI95” and “LCI95” indicated 95% confidence level of upper and lower values of Chao1 for each distance. Values of Chao1 index supported the results of rarefaction curve. PMID:25689047
Jena, Jyotsnarani; Kumar, Ravindra; Dixit, Anshuman; Pandey, Sony; Das, Trupti
2015-01-01
Simultaneous nitrate-N, phosphate and COD removal was evaluated from synthetic waste water using mixed microbial consortia in an anoxic environment under various initial carbon load (ICL) in a batch scale reactor system. Within 6 hours of incubation, enriched DNPAOs (Denitrifying Polyphosphate Accumulating Microorganisms) were able to remove maximum COD (87%) at 2 g/L of ICL whereas maximum nitrate-N (97%) and phosphate (87%) removal along with PHB accumulation (49 mg/L) was achieved at 8 g/L of ICL. Exhaustion of nitrate-N, beyond 6 hours of incubation, had a detrimental effect on COD and phosphate removal rate. Fresh supply of nitrate-N to the reaction medium, beyond 6 hours, helped revive the removal rates of both COD and phosphate. Therefore, it was apparent that in spite of a high carbon load, maximum COD and nutrient removal can be maintained, with adequate nitrate-N availability. Denitrifying condition in the medium was evident from an increasing pH trend. PHB accumulation by the mixed culture was directly proportional to ICL; however the time taken for accumulation at higher ICL was more. Unlike conventional EBPR, PHB depletion did not support phosphate accumulation in this case. The unique aspect of all the batch studies were PHB accumulation was observed along with phosphate uptake and nitrate reduction under anoxic conditions. Bioinformatics analysis followed by pyrosequencing of the mixed culture DNA from the seed sludge revealed the dominance of denitrifying population, such as Corynebacterium, Rhodocyclus and Paraccocus (Alphaproteobacteria and Betaproteobacteria). Rarefaction curve indicated complete bacterial population and corresponding number of OTUs through sequence analysis. Chao1 and Shannon index (H') was used to study the diversity of sampling. "UCI95" and "LCI95" indicated 95% confidence level of upper and lower values of Chao1 for each distance. Values of Chao1 index supported the results of rarefaction curve.
Liu, Feng; Zhang, Shunan; Wang, Yi; Li, Yong; Xiao, Runlin; Li, Hongfang; He, Yang; Zhang, Miaomiao; Wang, Di; Li, Xi; Wu, Jinshui
2016-01-15
The aim of this research was to assess the applicability of Myriophyllum (M.) aquaticum for swine wastewater treatment. Nitrogen (N) removal processes were investigated in M. aquaticum mesocosms with swine wastewater (SW), 50% diluted swine wastewater (50% SW), and two strengths of synthetic wastewater, 200 mg [Formula: see text] L(-1) (200 [Formula: see text] ) and 400 mg [Formula: see text] L(-1) (400 [Formula: see text] ). During a 28-day incubation period, the average [Formula: see text] and TN removal rates were 99.8% and 94.2% for 50% SW and 99.8% and 93.8% for SW, which were greater than 86.5% and 83.7% for 200 [Formula: see text] , and 73.7% and 74.1% for 400 [Formula: see text] , respectively. A maximum areal total nitrogen (TN) removal rate of 157.8 mg N m(-2) d(-1) was found in M. aquaticum mesocosms with SW. During the incubation period, the observed dynamics of [Formula: see text] concentrations in water and gene copy numbers of ammonia-oxidizing archaea (AOA), ammonia-oxidizing bacteria (AOB), nirK and nirS in soil unraveled strong nitrification and denitrification processes occurring in M. aquaticum mesocosms with swine wastewater. The N mass balance analysis indicated that plant uptake and soil N accumulation accounted for 17.9-42.2% and 18.0-43.8% of the initial TN load, respectively. The coupled nitrification and denitrification process was calculated to account for, on average, 36.8% and 62.8% of TN removal for 50% SW and SW, respectively. These findings demonstrated that the N uptake by M. aquaticum contributed to a considerable proportion of N removal. In particular, the activities of ammonia-oxidizing and denitrification microbes responsible for nitrification and denitrification processes in M. aquaticum mesocosm accelerated [Formula: see text] and TN removal from swine wastewater. Copyright © 2015 Elsevier Ltd. All rights reserved.
Wachter, Naihara; Aquino, José M; Denadai, Marina; Barreiro, Juliana C; Silva, Adilson J; Cass, Quezia B; Rocha-Filho, Romeu C; Bocchi, Nerilso
2018-06-06
The electrochemical degradation of ciprofloxacin-CIP (50 mg L -1 in 0.10 mol L -1 Na 2 SO 4 ) was investigated using a double-sided Ti-Pt/β-PbO 2 anode in a filter-press flow reactor, with identification of oxidation intermediates and follow-up of antimicrobial activity against Escherichia coli. The effect of solution pH, flow rate, current density, and temperature on the CIP removal rate was evaluated. All of these parameters did affect the CIP removal performance; thus, optimized electrolysis conditions were further explored: pH = 10, q V = 6.5 L min -1 , j = 30 mA cm -2 , and θ = 25 °C. Therefore, CIP was removed within 2 h, whereas ~75% of the total organic carbon concentration (TOC) was removed after 5 h and then, the solution no longer presented antimicrobial activity. When the electrochemical degradation of CIP was investigated using a single-sided boron-doped diamond (BDD) anode, its performance in TOC removal was similar to that of the Ti-Pt/β-PbO 2 anode; considering the higher oxidation power of BDD, the surprisingly good comparative performance of the Ti-Pt/β-PbO 2 anode was ascribed to significantly better hydrodynamic conditions attained in the filter-press reactor used with this electrode. Five initial oxidation intermediates were identified by LC-MS/MS and completely removed after 4 h of electrolysis; since they have also been determined in other degradation processes, there must be similarities in the involved oxidation mechanisms. Five terminal oxidation intermediates (acetic, formic, oxamic, propionic, and succinic acids) were identified by LC-UV and all of them (except acetic acid) were removed after 10 h of electrolysis.
Evaluation of Jet Fuel Induced Hearing Loss in Rats
2011-10-13
flow of approximately 20 liters per minute (lpm) through the nebulizer. This air flow coupled with the nebulizer nozzle design created an...inch PVC pipe contained the spray pattern. The pipe was initially reduced in size to accept an orifice plate which can be used to measure flow rate...chamber flow . Two drain ports were used to remove residual jet fuel which accumulated after a day‟s exposure. To achieve the 10 1500 mg/m 3
High flow ceramic pot filters.
van Halem, D; van der Laan, H; Soppe, A I A; Heijman, S G J
2017-11-01
Ceramic pot filters are considered safe, robust and appropriate technologies, but there is a general consensus that water revenues are limited due to clogging of the ceramic element. The objective of this study was to investigate the potential of high flow ceramic pot filters to produce more water without sacrificing their microbial removal efficacy. High flow pot filters, produced by increasing the rice husk content, had a higher initial flow rate (6-19 L h -1 ), but initial LRVs for E. coli of high flow filters was slightly lower than for regular ceramic pot filters. This disadvantage was, however, only temporarily as the clogging in high flow filters had a positive effect on the LRV for E. coli (from below 1 to 2-3 after clogging). Therefore, it can be carefully concluded that regular ceramic pot filters perform better initially, but after clogging, the high flow filters have a higher flow rate as well as a higher LRV for E. coli. To improve the initial performance of new high flow filters, it is recommended to further utilize residence time of the water in the receptacle, since additional E. coli inactivation was observed during overnight storage. Although a relationship was observed between flow rate and LRV of MS2 bacteriophages, both regular and high flow filters were unable to reach over 2 LRV. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cowbird removals unexpectedly increase productivity of a brood parasite and the songbird host.
Kosciuch, Karl L; Sandercock, Brett K
2008-03-01
Generalist brood parasites reduce productivity and population growth of avian hosts and have been implicated in population declines of several songbirds of conservation concern. To estimate the demographic effects of brood parasitism on Bell's Vireos (Vireo bellii), we removed Brown-headed Cowbirds (Molothrus ater) in a replicated switchback experimental design. Cowbird removals decreased parasitism frequency from 77% and 85% at unmanipulated plots to 58% and 47% at removal plots in 2004 and 2005, respectively. Vireo productivity per pair was higher at cowbird removal plots when years were pooled (mean = 2.6 +/- 0.2 [SE] young per pair) compared to unmanipulated plots (1.2 +/- 0.1). Nest desertion frequency was lower at cowbird removal plots (35% of parasitized nests) compared to unmanipulated plots (69%) because removal of host eggs was the proximate cue for nest desertion, and vireos experienced lower rates of egg loss at cowbird removal plots. Nest success was higher among unparasitized than parasitized nests, and parasitized nests at cowbird removal plots had a higher probability of success than parasitized nests at unmanipulated plots. Unexpectedly, cowbird productivity from vireo pairs was higher at cowbird removal plots (mean = 0.3 +/- 0.06 young per pair) than at unmanipulated plots (0.1 +/- 0.03) because fewer parasitized nests were deserted and the probability of nest success was higher. Our study provides the first evidence that increases in cowbird productivity may be an unintended consequence of cowbird control programs, especially during the initial years of trapping when parasitism may only be moderately reduced. Thus, understanding the demographic impacts of cowbird removals requires an informed understanding of the behavioral ecology of host-parasite interactions.
Selective Removal of Natural Occlusal Caries by Coupling Near-infrared Imaging with a CO2 Laser
Tao, You-Chen; Fried, Daniel
2011-01-01
Laser removal of dental hard tissue can be combined with optical, spectral or acoustic feedback systems to selectively ablate dental caries and restorative materials. Near-infrared (NIR) imaging has considerable potential for the optical discrimination of sound and demineralized tissue. Last year we successfully demonstrated that near-IR images can be used to guide a CO2 laser ablation system for the selective removal of artificial caries lesions on smooth surfaces. The objective of this study was to test the hypothesis that two-dimensional near-infrared images of natural occlusal caries can be used to guide a CO2 laser for selective removal. Two-dimensional NIR images were acquired at 1310-nm of extracted human molar teeth with occlusal caries. Polarization sensitive optical coherence tomography (PS-OCT) was also used to acquire depth-resolved images of the lesion areas. An imaging processing module was developed to analyze the NIR imaging output and generate optical maps that were used to guide a CO2 laser to selectively remove the lesions at a uniform depth. Post-ablation NIR images were acquired to verify caries removal. Based on the analysis of the NIR images, caries lesions were selectively removed with a CO2 laser while sound tissues were conserved. However, the removal rate varied markedly with the severity of decay and multiple passes were required for caries removal. These initial results are promising but indicate that the selective removal of natural caries is more challenging than the selective removal of artificial lesions due to varying tooth geometry, the highly variable organic/mineral ratio in natural lesions and more complicated lesion structure. PMID:21909225
Selective removal of natural occlusal caries by coupling near-infrared imaging with a CO II laser
NASA Astrophysics Data System (ADS)
Tao, You-Chen; Fried, Daniel
2008-02-01
Laser removal of dental hard tissue can be combined with optical, spectral or acoustic feedback systems to selectively ablate dental caries and restorative materials. Near-infrared (NIR) imaging has considerable potential for the optical discrimination of sound and demineralized tissue. Last year we successfully demonstrated that near-IR images can be used to guide a CO2 laser ablation system for the selective removal of artificial caries lesions on smooth surfaces. The objective of this study was to test the hypothesis that two-dimensional near-infrared images of natural occlusal caries can be used to guide a CO2 laser for selective removal. Two-dimensional NIR images were acquired at 1310-nm of extracted human molar teeth with occlusal caries. Polarization sensitive optical coherence tomography (PS-OCT) was also used to acquire depth-resolved images of the lesion areas. An imaging processing module was developed to analyze the NIR imaging output and generate optical maps that were used to guide a CO2 laser to selectively remove the lesions at a uniform depth. Post-ablation NIR images were acquired to verify caries removal. Based on the analysis of the NIR images, caries lesions were selectively removed with a CO2 laser while sound tissues were conserved. However, the removal rate varied markedly with the severity of decay and multiple passes were required for caries removal. These initial results are promising but indicate that the selective removal of natural caries is more challenging than the selective removal of artificial lesions due to varying tooth geometry, the highly variable organic/mineral ratio in natural lesions and more complicated lesion structure.
Selective Removal of Natural Occlusal Caries by Coupling Near-infrared Imaging with a CO(2) Laser.
Tao, You-Chen; Fried, Daniel
2008-03-01
Laser removal of dental hard tissue can be combined with optical, spectral or acoustic feedback systems to selectively ablate dental caries and restorative materials. Near-infrared (NIR) imaging has considerable potential for the optical discrimination of sound and demineralized tissue. Last year we successfully demonstrated that near-IR images can be used to guide a CO(2) laser ablation system for the selective removal of artificial caries lesions on smooth surfaces. The objective of this study was to test the hypothesis that two-dimensional near-infrared images of natural occlusal caries can be used to guide a CO(2) laser for selective removal. Two-dimensional NIR images were acquired at 1310-nm of extracted human molar teeth with occlusal caries. Polarization sensitive optical coherence tomography (PS-OCT) was also used to acquire depth-resolved images of the lesion areas. An imaging processing module was developed to analyze the NIR imaging output and generate optical maps that were used to guide a CO(2) laser to selectively remove the lesions at a uniform depth. Post-ablation NIR images were acquired to verify caries removal. Based on the analysis of the NIR images, caries lesions were selectively removed with a CO(2) laser while sound tissues were conserved. However, the removal rate varied markedly with the severity of decay and multiple passes were required for caries removal. These initial results are promising but indicate that the selective removal of natural caries is more challenging than the selective removal of artificial lesions due to varying tooth geometry, the highly variable organic/mineral ratio in natural lesions and more complicated lesion structure.
Salim, R; Al-Subu, M; Dawod, E
2008-05-01
Removal of cadmium from aqueous solutions using 20 species of plant leaves and combinations of these leaves have been studied. Several factors affecting the removal efficiency have been studied. The most efficient types of plant leaves for the removal of cadmium are those of styrax, plum, pomegranate and walnut. The interaction effect of the combined leaf samples on the efficiency of removal of cadmium has been found to be additive in combinations involving styrax plant leaves but seems to be antagonistic in all other combinations. The optimum experimental conditions for removal of cadmium have been found to be at pH 4.1, using high concentrations of naturally dried plant leaves, using ground leaves and to remove cadmium from agitated aqueous solutions. The percentage of metal removed at an initial cadmium concentration of 10mg/l by the most efficient types of leaves have been found to be 85% for styrax leaves, 85% for plum leaves, 80% for pomegranate leaves, 78% for walnut leaves and 77% for meddler leaves. The presence of foreign ions or complexing agents has been found to reduce the efficiency of removal of cadmium by plant leaves. About 80-85% of the cadmium in charged plant leaves has been released under the influence of changing the pH of the solution, addition of competing ions and the addition of EDTA. The results of removal of cadmium by plant leaves have been found to follow the Freundlich adsorption isotherm, first-order reaction with respect to cadmium and to have intra-pore diffusion as the rate-limiting step.
NASA Technical Reports Server (NTRS)
Sudbrack, Chantal K.; Draper, Susan L.; Gorman, Timothy T.; Telesman, Jack; Gab, Timothy P.; Hull, David R.
2012-01-01
Oxidation and the effects of high temperature exposures on notched fatigue life were considered for a powder metallurgy processed supersolvus heat-treated ME3 disk superalloy. The isothermal static oxidation response at 704 C, 760 C, and 815 C was consistent with other chromia forming nickel-based superalloys: a TiO2-Cr2O3 external oxide formed with a branched Al2O3 internal subscale that extended into a recrystallized - dissolution layer. These surface changes can potentially impact disk durability, making layer growth rates important. Growth of the external scales and dissolution layers followed a cubic rate law, while Al2O3 subscales followed a parabolic rate law. Cr- rich M23C6 carbides at the grain boundaries dissolved to help sustain Cr2O3 growth to depths about 12 times thicker than the scale. The effect of prior exposures was examined through notched low cycle fatigue tests performed to failure in air at 704 C. Prior exposures led to pronounced debits of up to 99 % in fatigue life, where fatigue life decreased inversely with exposure time. Exposures that produced roughly equivalent 1 m thick external scales at the various isotherms showed statistically equivalent fatigue lives, establishing that surface damage drives fatigue debit, not exposure temperature. Fractographic evaluation indicated the failure mode for the pre-exposed specimens involved surface crack initiations that shifted with exposure from predominately single intergranular initiations with transgranular propagation to multi-initiations from the cracked external oxide with intergranular propagation. Weakened grain boundaries at the surface resulting from the M23C6 carbide dissolution are partially responsible for the intergranular cracking. Removing the scale and subscale while leaving a layer where M23C6 carbides were dissolved did not lead to a significant fatigue life improvement, however, also removing the M23C6 carbide dissolution layer led to nearly full recovery of life, with a transgranular initiation typical to that observed in unexposed specimens.
NASA Astrophysics Data System (ADS)
Hosseini, Seiyed Mossa; Tosco, Tiziana; Ataie-Ashtiani, Behzad; Simmons, Craig T.
2018-03-01
Non-pumping reactive wells (NPRWs) filled by zero-valent iron (ZVI) can be utilized for the remediation of groundwater contamination of deep aquifers. The efficiency of NPRWs mainly depends on the hydraulic contact time (HCT) of the pollutant with the reactive materials, the extent of the well capture zone (Wcz), and the relative hydraulic conductivity of aquifer and reactive material (Kr). We investigated nitrate removal from groundwater using NPRWs filled by ZVI (in nano and micro scales) and examined the effect of NPRWs orientations (i.e. vertical, slanted, and horizontal) on HCT and Wcz. The dependence of HCT on Wcz for different Kr values was derived theoretically for a homogeneous and isotropic aquifer, and verified using particle tracking simulations performed using the semi-analytical particle tracking and pathlines model (PMPATH). Nine batch experiments were then performed to investigate the impact of mixed nano-ZVI, NZVI (0 to 2 g l-1) and micro-ZVI, MZVI (0 to 4 g l-1) on the nitrate removal rate (with initial NO3-=132 mg l-1). The NPRWs system was tested in a bench-scale sand medium (60 cm length × 40 cm width × 25 cm height) for three orientations of NPRWs (vertical, horizontal, and slanted with inclination angle of 45°). A mixture of nano/micro ZVI, was used, applying constant conditions of pore water velocity (0.024 mm s-1) and initial nitrate concentration (128 mg l-1) for five pore volumes. The results of the batch tests showed that mixing nano and micro Fe0 outperforms these individual materials in nitrate removal rates. The final products of nitrate degradation in both batch and bench-scale experiments were NO2-, NH4+, and N2(gas). The results of sand-box experiments indicated that the slanted NPRWs have a higher nitrate reduction rate (57%) in comparison with vertical (38%) and horizontal (41%) configurations. The results also demonstrated that three factors have pivotal roles in expected HCT and Wcz, namely the contrast between the hydraulic conductivity of aquifer and reactive materials within the wells, the mass of Fe0 in the NPRWs, and the orientation of NPRWs adopted. A trade-off between these factors should be considered to increase the efficiency of remediation using the NPRWs system.
Natural stent in the management of post-intubation tracheal stenosis.
Park, Hye Yun; Kim, Hojoong; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung
2009-05-01
The treatment choice for post-intubation tracheal stenosis (PITS) in patients for whom surgery is not initially feasible is bronchoscopic silicone stenting. A new silicone stent, called the Natural stent (N stent), was investigated for its clinical efficacy and safety in patients with PITS. A retrospective review was conducted of 32 patients with PITS who underwent N stenting between November 2001 and December 2006 and were followed for at least 12 months. Airway dilatation with combined modalities such as Nd:YAG laser, ballooning or bougienage was followed by N stent insertion. After intervention, all patients had symptomatic and spirometric improvement without immediate complications. Removal of the stent without re-stenosis was successful in 38% of the patients at a median time of 7 months after insertion. The stent could not be removed or needed reinsertion in 31% of patients, and 16% of patients underwent surgery after initial stabilization by stenting. Late complications were stent migration (34%), mucostasis (31%), granulation tissue formation (38%) and re-stenosis (40%). All patients tolerated the management of complications during a median follow up of 22 months. Bronchoscopic N stenting is an effective treatment for patients with PITS in whom surgery is not feasible on initial presentation. Further stent development is necessary to reduce the late complication rate.
Hotel guest's $14.5 million jury verdict set aside on appeal.
1999-08-20
A Missouri Court of Appeals judge reversed a $14.5 million judgement against [name removed] Inc., which had been held liable for the beating and sexual assault of a guest in its hotel. The guest, identified as [name removed], had requested an upgrade to a concierge room, to increase her safety, but the hotel did not fill her request. When [name removed] opened her hotel room door the next morning, an assailant attacked, beat and raped her. The assailant escaped hotel security, but was later apprehended. The initial case against [name removed] and the assailant resulted in a $22.5 million judgement for [name removed] Both parties appealed. [Name removed] prevailed in its argument that the initial trial judge misinstructed the jury, and that [name removed] was unable to show clear and convincing evidence that the hotel's willful or conscious disregard for guest safety caused the situation. However, the court ruled against [name removed] on the basis of [name removed]'s fear-of-AIDS claim, because of her exposure to the virus.
Models of Disease Vector Control: When Can Aggressive Initial Intervention Lower Long-Term Cost?
Oduro, Bismark; Grijalva, Mario J; Just, Winfried
2018-04-01
Insecticide spraying of housing units is an important control measure for vector-borne infections such as Chagas disease. As vectors may invade both from other infested houses and sylvatic areas and as the effectiveness of insecticide wears off over time, the dynamics of (re)infestations can be approximated by [Formula: see text]-type models with a reservoir, where housing units are treated as hosts, and insecticide spraying corresponds to removal of hosts. Here, we investigate three ODE-based models of this type. We describe a dual-rate effect where an initially very high spraying rate can push the system into a region of the state space with low endemic levels of infestation that can be maintained in the long run at relatively moderate cost, while in the absence of an aggressive initial intervention the same average cost would only allow a much less significant reduction in long-term infestation levels. We determine some sufficient and some necessary conditions under which this effect occurs and show that it is robust in models that incorporate some heterogeneity in the relevant properties of housing units.
Effect of delignification upon in vitro digestion of forage cellulose.
Darcy, B K; Belyea, R L
1980-10-01
Orchardgrass forages harvested at two maturities (early and late) were ground through two screens (1 and 8 mm) and digested in vitro as intact forage and forage delignified by permanganate oxidation. Initial and residual cell wall, initial and residual cellulose and potentially digestible cellulose were greater in late intact forage than in the early. In the delignified forage, late cut forage had less residual cellulose than did the early, but initial and potentially digestible cellulose were similar. Particle size had less consistent and smaller effects upon cell wall and cellulose than did maturity. Cellulose of intact orchardgrass was 64% digested at 72 h vs 94% for cellulose of delignified orchardgrass. Digestion rate of cellulose was .0197 and .0220 logn units/hr for early and late cut intact forage and .0554 and .0719 logn units/hr for early and late cut delignified forage. Removal of the inhibitory effects of lignin increased the amount of digestible cellulose, increased the rate at which cellulose degraded and decreased the indigestible cellulose residue. Reduction in lignin could greatly improve forage intake and utilization at moderate levels of animal production.
NASA Astrophysics Data System (ADS)
Nikonova, L. G.; Golovatskaya, E. A.; Terechshenko, N. N.
2018-03-01
The research presents quantitative estimates of the decomposition rate of plant residues at the initial stages of the decay of two plant species (Eriophorum vaginatum and Sphagnum fuscum) in a peat deposit of the oligotrophic bog in the southern taiga subzone of Western Siberia. We also studied a change in the content of total carbon and nitrogen in plant residues and the activity of microflora in the initial stages of decomposition. At the initial stage of the transformation process of peat-forming plants the losses of mass of Sph. fuscum is 2.5 times lower then E. vaginatum. The most active mass losses, as well as a decrease in the total carbon content, is observed after four months of the experiment. The most active carbon removal is characteristic for E. vaginatum. During the decomposition of plant residues, the nitrogen content decreases, and the most intense nitrogen losses were characteristic for Sph. fuscum. The microorganisms assimilating organic and mineral nitrogen are more active in August, the oligotrophic and cellulolytic microorganisms – in July.
A New Strategy to Enhance Cavitational Tissue Erosion Using a High-Intensity, Initiating Sequence
Xu, Zhen; Fowlkes, J. Brian; Cain, Charles A.
2009-01-01
Our previous studies have shown that pulsed ultrasound can physically remove soft tissue through cavitation. A new strategy to enhance the cavitation-induced erosion is proposed wherein tissue erosion is initiated by a short, high-intensity sequence of pulses and sustained by lower intensity pulses. We investigated effects of the initiating sequence on erosion and cavitation sustained by lower intensity pulses. Multiple three-cycle pulses at a pulse repetition frequency of 20 kHz delivered by a 788-kHz focused transducer were used for tissue erosion. Fixing the initiating sequence at ISPPA of 9000 W/cm2, 16 combinations of different numbers of pulses within the initiating sequence and different sustaining pulse intensities were tested. Results showed: the initiating sequence increases the probability of erosion occurrence and the erosion rate with only slight overall increases in propagated energy; the initiating sequence containing more pulses does not increase the sustained cavitation period; and if extinguished and reinitiated, the sustained cavitation period becomes shorter after each initiation, although the waiting time between adjacent cavitation periods is random. The high-intensity, initiating sequence enhances cavitational tissue erosion and enables erosion at intensities significantly lower than what is required to initiate erosion. PMID:16921893
Cycoń, Mariusz; Żmijowska, Agnieszka; Wójcik, Marcin; Piotrowska-Seget, Zofia
2013-03-15
The ability of diazinon-degrading Serratia marcescens to remove organophosphorus pesticides (OPPs), i.e. chlorpyrifos (CP), fenitrothion (FT), and parathion (PT) was studied in a mineral salt medium (MSM) and in three soils of different characteristics. This strain was capable of using all insecticides at concentration of 50 mg/l as the only carbon source when grown in MSM, and 58.9%, 70.5%, and 82.5% of the initial dosage of CP, FT, and PT, respectively was degraded within 14 days. The biodegradation experiment showed that autochthonous microflora in all soils was characterized by a degradation potential of all tested OPPs; however, the initial lag phases for degradation of CP and FT, especially in sandy soil, were observed. During the 42-day experiment, 45.3%, 61.4% and 72.5% of the initial dose of CP, FT, and PT, respectively, was removed in sandy soil whereas the degradation of CP, FT, and PT in the same period, in sandy loam and silty soils reached 61.4%, 79.7% and 64.2%, and 68.9%, 81.0% and 63.6%, respectively. S. marcescens introduced into sterile soils showed a higher degradation potential (5-13%) for OPPs removal than those observed in non-sterile soil with naturally occurring attenuation. Inoculation of non-sterile soils with S. marcescens enhanced the disappearance rates of all insecticides, and DT50 for CP, FT, and PT was reduced by 20.7, 11.3 and 13.0 days, and 11.9, 7.0 and 8.1 days, and 9.7, 14.5 and 12.6 days in sandy, sandy loam, and silty soils, respectively, in comparison with non-sterile soils with only indigenous microflora. This ability of S. marcescens makes it a suitable strain for bioremediation of soils contaminated with OPPs. Copyright © 2013 Elsevier Ltd. All rights reserved.
Figuring process of potassium dihydrogen phosphate crystal using ion beam figuring technology.
Li, Furen; Xie, Xuhui; Tie, Guipeng; Hu, Hao; Zhou, Lin
2017-09-01
Currently, ion beam figuring (IBF) technology has presented many excellent performances in figuring potassium dihydrogen phosphate (KDP) crystals, such as it is a noncontact figuring process and it does not require polishing fluid. So, it is a very clean figuring process and does not introduce any impurities. However, the ion beam energy deposited on KDP crystal will heat the KDP crystal and may generate cracks on it. So, it is difficult directly using IBF technology to figure KDP crystal, as oblique incident IBF (OI-IBF) has lower heat deposition, higher removal rate, and smoother surface roughness compared to normal incident IBF. This paper studied the process of using OI-IBF to figure KDP crystal. Removal rates and removal functions at different incident angles were first investigated. Then heat depositions on a test work piece were obtained through experiments. To validate the figuring process, a KDP crystal with a size of 200 mm×200 mm×12 mm was figured by OI-IBF. After three iterations using the OI-IBF process, the surface error decreases from the initial values with PV 1.986λ RMS 0.438λ to PV 0.215λ RMS 0.035λ. Experimental results indicate that OI-IBF is feasible and effective to figure KDP crystals.
Model Implementation of Boron Removal Using CaCl2-CaO-SiO2 Slag System for Solar-Grade Silicon
NASA Astrophysics Data System (ADS)
Chen, Hui; Wang, Ye; Zheng, Wenjia; Li, Qincan; Yuan, Xizhi; Morita, Kazuki
2017-12-01
A new CaCl2-CaO-SiO2 slag system was recently proposed to remove boron from metallurgy-grade silicon by oxidized chlorination and evaporation. To further investigate the boron transformation process at a high temperature, a model implementation to present the transfer of boron from molten silicon to the gas phase via slag is introduced. Heat transfer, fluid flow, the chemical reactions at the interface and surface, the mass transfer and diffusion of boron in the molten silicon and slag, and the evaporation of BOCl and CaCl2 were coupled in this model. After the confirmation of the thermal field, other critical parameters, including the boron partition ratios ( L B) for this slag from 1723 K to 1823 K (1450 °C to 1550 °C), the thicknesses of the velocity boundary layer at the surface and interface, the mass transfer coefficients of the boundary layer at the surface and interface, and partial pressure of BOCl in the gas phase were analyzed to determine the rate-limiting step. To verify this model implementation, boron removal experiments were carried out at various temperatures and with various initial mass ratios of slag to silicon ( μ). The evaporation rate of CaCl2 was also measured by thermogravimetry analysis (TGA).
Zhang; Lindberg
2000-10-02
From 1996 to 1998 we determined dissolved gaseous mercury (DGM) in waters of the Everglades Nutrient Removal Project (ENR), a constructed wetlands. The concentrations of DGM measured in these waters (mean 7.3 +/- 9.5 pg l(-1)) are among the lowest reported in the literature, and suggest a system often near or slightly above equilibrium with Hg in ambient air. DGM exhibited both seasonal and diel trends, peaking at midday and during the summer. A simple box budget model of DGM in waters of the Everglades was developed using an interactive spreadsheet based on a mass balance among light-induced reduction of HgII (production of DGM), Hg0 oxidation (removal), and Hg0 evasion in a box (water column) consisting of a surface region with sunlight available and a lower dark region. The modeling results suggest high sensitivity of hourly DGM concentrations to DGM production rates and initial DGM levels. The sensitivity to Hg oxidation is lower than the sensitivity to DGM production. The model performance demonstrates successful simulations of a variety of DGM trends in the Everglades. In particular, it clearly demonstrates how it is possible to measure comparable rates of evasion over several Everglades sites with different DGM concentrations.
Amphiphobic Polytetrafluoroethylene Membranes for Efficient Organic Aerosol Removal.
Feng, Shasha; Zhong, Zhaoxiang; Zhang, Feng; Wang, Yong; Xing, Weihong
2016-04-06
Polytetrafluoroethylene (PTFE) membrane is an extensively used air filter, but its oleophilicity leads to severe fouling of the membrane surface due to organic aerosol deposition. Herein, we report the fabrication of a new amphiphobic 1H,1H,2H,2H-perfluorodecyl acrylate (PFDAE)-grafted ZnO@PTFE membrane with enhanced antifouling functionality and high removal efficiency. We use atomic-layer deposition (ALD) to uniformly coat a layer of nanosized ZnO particles onto porous PTFE matrix to increase surface area and then subsequently graft PFDAE with plasma. Consequently, the membrane surface showed both superhydrophobicity and oleophobicity with a water contact angle (WCA) and an oil contact angle (OCA) of 150° and 125°, respectively. The membrane air permeation rate of 513 (m(3) m(-2) h(-1) kPa(-1)) was lower than the pristine membrane rate of 550 (m(3) m(-2) h(-1) kPa(-1)), which indicates the surface modification slightly decreased the membrane air permeation. Significantly, the filtration resistance of this amphiphobic membrane to the oil aerosol system was much lower than the initial one. Moreover, the filter exhibited exceptional organic aerosol removal efficiencies that were greater than 99.5%. These results make the amphiphobic PTFE membranes very promising for organic aerosol-laden air-filtration applications.
Yatagai, Tomonori; Ohkawa, Yoshiko; Kubo, Daichi; Kawase, Yoshinori
2017-01-02
The hydroxyl radical generation in an electro-Fenton process with a gas-diffusion electrode which is strongly linked with electro-chemical generation of hydrogen peroxide and iron redox cycle was studied. The OH radical generation subsequent to electro-chemical generations of H 2 O 2 was examined under the constant potential in the range of Fe 2+ dosage from 0 to 1.0 mM. The amount of generated OH radical initially increased and gradually decreased after the maximum was reached. The initial rate of OH radical generation increased for the Fe 2+ dosage <0.25 mM and at higher Fe 2+ dosages remained constant. At higher Fe 2+ dosages the precipitation of Fe might inhibit the enhancement of OH radical generation. The experiments for decolorization and total organic carbon (TOC) removal of azo-dye Orange II by the electro-Fenton process were conducted and the quick decolorization and slow TOC removal of Orange II were found. To quantify the linkages of OH radical generation with dynamic behaviors of electro-chemically generated H 2 O 2 and iron redox cycle and to investigate effects of OH radical generation on the decolorization and TOC removal of Orange II, novel reaction kinetic models were developed. The proposed models could satisfactory clarify the linkages of OH radical generation with electro-chemically generated H 2 O 2 and iron redox cycle and simulate the decolorization and TOC removal of Orange II by the electro-Fenton process.
Gatsios, Evangelos; Hahladakis, John N; Gidarakos, Evangelos
2015-05-01
In the present work, the efficiency evaluation of electrocoagulation (EC) in removing toxic metals from a real industrial wastewater, collected from Aspropyrgos, Athens, Greece was investigated. Manganese (Mn), copper (Cu) and zinc (Zn) at respective concentrations of 5 mg/L, 5 mg/L and 10 mg/L were present in the wastewater (pH=6), originated from the wastes produced by EBO-PYRKAL munitions industry and Hellenic Petroleum Elefsis Refineries. The effect of operational parameters such as electrode combination and distance, applied current, initial pH and initial metal concentration, was studied. The results indicated that Cu and Zn were totally removed in all experiments, while Mn exhibited equally high removal percentages (approximately 90%). Decreasing the initial pH and increasing the distance between electrodes, resulted in a negative effect on the efficiency and energy consumption of the process. On the other hand, increasing the applied current, favored metal removal but resulted in a power consumption increase. Different initial concentrations did not affect metal removal efficiency. The optimal results, regarding both cost and EC efficiency, were obtained with a combination of iron electrodes, at 2 cm distance, at initial current of 0.1 A and pH=6. After 90 min of treatment, maximum removal percentages obtained were 89% for Mn, 100% for Cu and 100% for Zn, at an energy consumption of 2.55 kWh/m(3). Copyright © 2015 Elsevier Ltd. All rights reserved.
Gallastegui, G; Muñoz, R; Barona, A; Ibarra-Berastegi, G; Rojo, N; Elías, A
2011-01-30
The influence of water irrigation on both the long-term and short-term performance of p-xylene biodegradation under several organic loading scenarios was investigated using an organic packing material composed of pelletised sawdust and pig manure. Process operation in a modular biofilter, using no external water supply other than the moisture from the saturated inlet air stream, showed poor p-xylene abatement efficiencies (≈33 ± 7%), while sustained irrigation every 25 days rendered a high removal efficiency (RE) for a critical loading rate of 120 g m(-3)h(-1). Periodic profiles of removal efficiency, temperature and moisture content were recorded throughout the biofilter column subsequent to each biofilter irrigation. Hence, higher p-xylene biodegradation rates were always initially recorded in the upper module, which resulted in a subsequent increase in temperature and a decrease in moisture content. This decrease in the moisture content in the upper module resulted in a higher removal rate in the middle module, while the moisture level in the lower module steadily increased as a result of water condensation. Based on these results, mass balance calculations performed using measured bed temperatures and relatively humidity values were successfully used to account for water balances in the biofilter over time. Finally, the absence of bed compaction after 550 days of continuous operation confirmed the suitability of this organic material for biofiltration processes. Copyright © 2010 Elsevier B.V. All rights reserved.
Sun, Jiaji; Chen, Lei; Rene, Eldon R; Hu, Qian; Ma, Weifang; Shen, Zhenyao
2018-07-01
The main aim of this study was to remove nitrogen compounds from reclaimed water and reuse the water in semi-arid riverine lake systems. In order to assess the nitrogen removal efficiencies in different natural environments, laboratory scale column experiments were performed using sterilized soil (SS), silty clay (SC), soil with submerged plant (SSP) and biochar amendment soil (BCS). The initial concentration of NO 3 - -N and the flow rate was maintained constant at 15 mg L -1 and 0.6 ± 0.1 m d -1 , respectively. Among the tested columns, both SSP and BCS were able to achieve NO 3 - -N levels <0.2 mg L -1 in the treated reclaimed water. The results from bacterial community structure analysis, using 454 pyrosequencing of 16s rRNA genes, showed that the dominant denitrifier was Bacillus at the genera level. Copyright © 2018 Elsevier Ltd. All rights reserved.
Investigation of furfural biodegradation in a continuous inflow cyclic biological reactor.
Moussavi, Gholamreza; Leili, Mostafa; Nadafi, Kazem
2016-01-01
The performance of a continuous inflow cyclic biological reactor (CBR) containing moving media was investigated for the degradation of high concentrations of furfural. The effects of hydraulic retention time (HRT) and furfural initial concentrations (loading rate), as main operating parameters, on the bioreactor performance were studied. The results indicated that the CBR could remove over 98% of furfural and 71% of its chemical oxygen demand (COD) at inlet furfural concentrations up to 1,200 mg L(-1) (2.38 g L(-1) d(-1)), a 6-h cycle time and HRT of 12.1 h. The removal efficiency decreased slightly from 98 to 94% when HRT decreased from 12.1 to 10.5 h. The average removal efficiency of furfural and COD during the 345-day operational period under steady-state conditions were 97.7% and 82.1%, respectively. The efficiency also increased approximately 17.2% after addition of synthetic polyurethane cubes as moving media at a filling ratio of 10%.
Evaluation of Zeolite Permeable Treatment Wall for the Removal of Strontium-90 from Groundwater
NASA Astrophysics Data System (ADS)
Seneca, S. M.; Bronner, C.; Ross, E.; Rabideau, A. J.
2009-05-01
Experimental and modeling studies have been initiated to evaluate the potential performance of a permeable treatment wall comprised of zeolite-rich rock for the removal of strontium-90 from groundwater. Preliminary column studies were performed using a synthetic groundwater referenced to anticipate field conditions, with a focus on quantifying the competitive ion exchange among five cations (Na+, K+, Ca2+, Mg2+, and Sr2+). Variations of the column configurations addressed the effects of particle size and flow rates on removal efficiency. In general, kinetic effects were not significant for the test conditions. Ongoing studies are focused on the comparison of zeolites obtained from two sources: Teague Mineral Products (Adrian, OR) and Bear River Zeolite (Preston, UT), and on the possible influence of native soil that is mixed with treatment wall material during construction. The results of the performance assessment will support the possible deployment of a full scale treatment wall at a Western New York nuclear facility.
Clinical application of micro-implant anchorage in initial orthodontic retraction.
Wahabuddin, Shaji; Mascarenhas, Rohan; Iqbal, Mahamad; Husain, Akhter
2015-02-01
Micro-implant is a device that is temporarily fixed to bone for the purpose of enhancing orthodontic anchorage either by supporting the teeth of the reactive unit or by obviating the need for the reactive unit altogether, and which is subsequently removed after use. The purpose of this study was to evaluate the clinical efficiency of micro-implants in reinforcing anchorage during the initial retraction of anterior teeth, check the rate of initial retraction for 8 weeks, and assess the stability of micro-implants during this period. Eighteen micro-implants were placed (10 in the maxilla and 8 in the mandible) and immediately loaded with 200-250 g of force using 9-mm closed coil Nitinol springs. The amount of space closure was measured every 2 weeks until the eighth week. Cephalometric measurements were made at the end of the study to evaluate anchor loss, if any. Micro-implant stability was also assessed. The rate of initial retraction in the maxilla at the end of 8 weeks was 1.65 mm/quadrant and 1.51 mm/quadrant in the mandible. The amount of retraction on the left side of the arches was 1.66 mm/quadrant and 1.49 mm/quadrant on the right side. The average initial retraction for both arches per month was 0.78 mm. An anchor loss of 0.1 mm (0.06%) was observed in the maxilla while no mandibular anchor loss was recorded. The rate of initial retraction observed in the maxilla was more than that achieved in the mandible. Initial retraction was also more on the left side of the arches. There was no anchor loss in the mandible. The micro-implant-reinforced anchorage was helpful in minimizing anchor loss and accepted heavy traction forces but did not bring about a faster rate of retraction.
[Bromate reduction by granular activated carbon].
Huang, Xin; Gao, Nai-yun; Lu, Pin-pin
2007-10-01
Batch experiments were conducted to evaluate the kinetics of reducing bromate to bromide by granular activated carbon. Solution conditions were studied in details, such as pH, ionic strength, temperature and initial bromate concentration. The results showed the removal capacity of GAC was positively relevant to surface basic functional groups. The whole process was inhibited by other anions in solution and the inhibition sequence was NO3(-) > SO4(2-) > Cl(-). Pseudo-second order rate equation and intraparticle diffusion model were applied to fit the process of bromate reduction and the process of bromide formation, respectively, with regression coefficients higher than 0.97 at most cases. Bromate removal was found to be favored under conditions with low pH value and low ionic strength. Both sorption rate of bromate and formation rate of bromide were decreased, and then increased along with the increase of temperature during 15-42 degree C. In this experiment, the maximum adsorption capacity of GAC is 769.23 micromol/g (98.4 mg/g), whereas the sorption process is slow and easily influenced. It is concluded that the sorption of bromate by the micropore portion of GAC was influenced by the release of bromide.
Cholecystectomy: from Langenbuch to natural orifice transluminal endoscopic surgery.
Soper, Nathaniel J
2011-07-01
Gallstones have led to pain and complications in humankind for millennia. Beginning in the 1880s, cholecystectomy, performed through a sizable abdominal incision, was the treatment of choice for symptomatic cholelithiasis. During the late 1980s pioneering surgeons first used laparoscopic techniques to remove the gallbladder. Although initially associated with a significantly increased rate of bile duct injury, the clinical advantages of laparoscopy compared to open operation became readily apparent, ushering in the "laparoscopic revolution." More recently, attempts at rendering cholecystectomy even less invasive--smaller or fewer incisions or eliminating abdominal incisions altogether--have been described, with limited clinical series reported. At the current time, laparoscopic cholecystectomy is the gold standard for gallbladder removal, and any newer techniques must be demonstrated to result in superior outcomes for widespread adoption.
Paxéus, N
2004-01-01
The removal of commonly used pharmaceuticals (ibuprofen, naproxen, diclofenac, gemfibrozil, carbamazepine, atenolol, metoprolol and trimethoprim) and a biocide (triclosan) in operating wastewater treatment plants in five EU countries has been studied. Under normal operating conditions the acidic drugs and triclosan were partially removed with removal rates varying from ca. 20 to >95%. The highest removal rate was found for ibuprofen and triclosan (>90%) followed by naproxen (80%), gemfibrozil (55%) and diclofenac (39%). Ibuprofen undergoes an oxidative transformation to corresponding hydroxy- and carboxy-metabolites, which contributes to its high removal rate. Disturbances in the activated sludge process resulted in lower removal rates for all acidic drugs, mostly for diclofenac (<10% removed) but also for ibuprofen (<60% removed). The treatment of wastewaters by activated sludge usually did not result in any practical removal (<10%) of neutral carbamazepine or basic atenolol, metoprolol and trimethoprim. The removal rates of the investigated drugs and triclosan are discussed in terms of mechanisms responsible for their removal. Discharges of carbamazepine, diclofenac, gemfibrozil, naproxen, triclosan and trimethoprim from WWTPs to the aquatic environment, expressed as the average concentration in the effluent and the daily discharged quantity per person served by WWTPs were assessed.
Removal of uranium from aqueous solution by a low cost and high-efficient adsorbent
NASA Astrophysics Data System (ADS)
Liu, Yun-Hai; Wang, You-Qun; Zhang, Zhi-Bin; Cao, Xiao-Hong; Nie, Wen-Bin; Li, Qin; Hua, Rong
2013-05-01
In this study, a low-cost and high-efficient carbonaceous adsorbent (HTC-COOH) with carboxylic groups was developed for U(VI) removal from aqueous solution compared with the pristine hydrothermal carbon (HTC). The structure and chemical properties of resultant adsorbents were characterized by Scanning electron microscope (SEM), N2 adsorption-desorption, Fourier transform-infrared spectra (FT-IR) and acid-base titration. The key factors (solution pH, contact time, initial U(VI) concentrations and temperature) affected the adsorption of U(VI) on adsorbents were investigated using batch experiments. The adsorption of U(VI) on HTC and HTC-COOH was pH-dependent, and increased with temperature and initial ion concentration. The adsorption equilibrium of U(VI) on adsorbents was well defined by the Langmuir isothermal equation, and the monolayer adsorption capacity of HTC-COOH was found to be 205.8 mg/g. The kinetics of adsorption was very in accordance with the pseudo-second-order rate model. The adsorption processes of U(VI) on HTC and HTC-COOH were endothermic and spontaneous in nature according to the thermodynamics of adsorption. Furthermore, HTC-COOH could selectively adsorption of U(VI) in aqueous solution containing co-existing ions (Mg2+, Co2+, Ni2+, Zn2+ and Mn2+). From the results of the experiments, it is found that the HTC-COOH is a potential adsorbent for effective removal of U(VI) from polluted water.
Liu, Wen; Zhao, Xiao; Borthwick, Alistair G L; Wang, Yanqi; Ni, Jinren
2015-09-09
Fe-deposited titanate nanotubes (Fe-TNTs) with high photocatalytic activity and adsorptive performance were synthesized through a one-step hydrothermal method. Initial As(III) oxidation followed by As(V) adsorption by Fe-TNTs could simultaneously remove these two toxic pollutants from aqueous solutions. The apparent rate constant value for photo-oxidation of As(III) under UV irradiation by Fe-TNTs was almost 250 times that of unmoidified TNTs. Under visible light, the Fe-TNTs also exhibited enhanced photocatalytic activity after Fe was deposited. Fe3+ located in the interlayers of TNTs acted as temporary electron- or hole-trapping sites, and attached α-Fe2O3 played the role of a charge carrier for electrons transferred from TNTs. These two effects inhibited electron-hole pair recombination thus promoting photocatalysis. Moreover, the As(V) adsorptive performance of Fe-TNTs also improved, owing to the presence of additional adsorption sites, α-Fe2O3, as well as increased pHPZC. Furthermore, Fe-TNTs exhibited good photocatalytic and adsorptive performace even after 5 reuse cycles. The present tests, concerning an initial As(III) photocatalysis and subsequent As(V) adsorption process, highlight the feasibility and importance of Fe used to modify TNTs. This study proposes a feasible method to simultaneously remove As(III) and As(V) from contaminated water using a novel Ti-based nanomaterial.
Liquid Phase adsorption kinetics and equilibrium of toluene by novel modified-diatomite.
Sheshdeh, Reza Khalighi; Abbasizadeh, Saeed; Nikou, Mohammad Reza Khosravi; Badii, Khashayar; Sharafi, Mohammad Sadegh
2014-01-01
The adsorption equilibria of toluene from aqueous solutions on natural and modified diatomite were examined at different operation parameters such as pH, contact time, initial toluene concentration was evaluated and optimum experimental conditions were identified. The surface area and morphology of the nanoparticles were characterized by SEM, BET, XRD, FTIR and EDX analysis. It was found that in order to obtain the highest possible removal of toluene, the experiments can be carried out at pH 6, temperature 25°C, an agitation speed of 200 rpm, an initial toluene concentration of 150 mg/L, a centrifugal rate of 4000 rpm, adsorbent dosage = 0.1 g and a process time of 90 min. The results of this work show that the maximum percentage removal of toluene from aqueous solution in the optimum conditions for NONMD was 96.91% (145.36 mg/g). Furthermore, under same conditions, the maximum adsorption of natural diatomite was 71.45% (107.18 mg/g). Both adsorption kinetic and isotherm experiments were carried out. The experimental data showed that the adsorption follows the Langmuir model and Freundlich model on natural and modified diatomite respectively. The kinetics results were found to conform well to pseudo-second order kinetics model with good correlation. Thus, this study demonstrated that the modified diatomite could be used as potential adsorbent for removal of toluene from aqueous solution.
Durango-Usuga, Paula; Guzmán-Duque, Fernando; Mosteo, Rosa; Vazquez, Mario V; Peñuela, Gustavo; Torres-Palma, Ricardo A
2010-07-15
An experimental design methodology was applied to evaluate the decolourization of crystal violet (CV) dye by electrocoagulation using iron or aluminium electrodes. The effects and interactions of four parameters, initial pH (3-9), current density (6-28 A m(-2)), substrate concentration (50-200 mg L(-1)) and supporting electrolyte concentration (284-1420 mg L(-1) of Na(2)SO(4)), were optimized and evaluated. Although the results using iron anodes were better than for aluminium, the effects and interactions of the studied parameters were quite similar. With a confidence level of 95%, initial pH and supporting electrolyte concentration showed limited effects on the removal rate of CV, whereas current density, pollutant concentration and the interaction of both were significant. Reduced models taking into account significant variables and interactions between variables have shown good correlations with the experimental results. Under optimal conditions, almost complete removal of CV and chemical oxygen demand were obtained after electrocoagulation for 5 and 30 min, using iron and aluminium electrodes, respectively. These results indicate that electrocoagulation with iron anodes is a rapid, economical and effective alternative to the complete removal of CV in waters. Evolutions of pH and residual iron or aluminium concentrations in solution are also discussed. 2010 Elsevier B.V. All rights reserved.
Fito, Jemal; Tefera, Nurelegne; Kloos, Helmut; Van Hulle, Stijn W H
2018-06-07
This study aimed to investigate the physicochemical properties of sugar industry and ethanol distillery wastewater and the treatment of the blended wastewater through a two-stage anaerobic reactor. For this treatment, different initial chemical oxygen demand (COD) concentrations (5-20 g/L) and hydraulic retention times (HRTs) (2-10 days) were applied. The sugar industry effluent characteristics obtained in terms of organic matter (mg/L) were as follows: 5 days biochemical oxygen demand (BOD 5 ): 654.5-1,968; COD: 1,100-2,148.9; total solids (TS): 2,467-4,012 mg/L; and pH: 6.93-8.43. The ethanol distillery spent wash strengths obtained were: BOD 5 : 27,600-42,921 mg/L; COD: 126,000-167,534 mg/L; TS: 140,160-170,000 mg/L; and pH: 3.9-4.2. Maximum COD removal of 65% was obtained at optimum condition (initial COD concentration of 10 g/L and HRT of 10 days), and maximum color removal of 79% was recorded under similar treatment conditions. Hence, the performance of the two-stage anaerobic reactor for simultaneous removal of COD and color from high-strength blended wastewater is promising for scaling up in order to mitigate environmental problems of untreated effluent discharge.
Sljivić, M; Smiciklas, I; Plećas, I; Pejanović, S
2011-07-01
The kinetics of Cu2+ sorption on to zeolite, clay and diatomite was investigated as a function of initial metal concentrations. For consideration of the mass transfer phenomena, single resistance models based on both film and intraparticle diffusion were tested and compared. The obtained results suggested that the rate-limiting step in Cu2+ sorption strongly depended on the sorbent type, as well as on initial cation concentration. The decrease in external mass transfer coefficients with the increase in initial metal concentrations was in excellent agreement with expressions based on Sherwood and Schmidt dimensionless numbers. The internal diffusivities through zeolite particles were in the range 1.0 x 10(-11) to 1.0 x 10(-13) m2/min, depending on the Cu2+ concentration and the applied theoretical model.
Chen, Mingjun; Liu, Henan; Cheng, Jian; Yu, Bo; Fang, Zhen
2017-07-01
In order to achieve the deterministic finishing of optical components with concave surfaces of a curvature radius less than 10 mm, a novel magnetorheological finishing (MRF) process using a small ball-end permanent-magnet polishing head with a diameter of 4 mm is introduced. The characteristics of material removal in the proposed MRF process are studied. The model of the material removal function for the proposed MRF process is established based on the three-dimensional hydrodynamics analysis and Preston's equation. The shear stress on the workpiece surface is calculated by means of resolving the presented mathematical model using a numerical solution method. The analysis result reveals that the material removal in the proposed MRF process shows a positive dependence on shear stress. Experimental research is conducted to investigate the effect of processing parameters on the material removal rate and improve the surface accuracy of a typical rotational symmetrical optical component. The experimental results show that the surface accuracy of the finished component of K9 glass material has been improved to 0.14 μm (PV) from the initial 0.8 μm (PV), and the finished surface roughness Ra is 0.0024 μm. It indicates that the proposed MRF process can be used to achieve the deterministic removal of surface material and perform the nanofinishing of small curvature radius concave surfaces.
Alketife, Ahmed M; Judd, Simon; Znad, Hussein
2017-01-01
The synergistic effects and optimization of nitrogen (N) and phosphorus (P) concentrations on the growth of Chlorella vulgaris (CCAP 211/11B, CS-42) and nutrient removal have been investigated under different concentrations of N (0-56 mg/L) and P (0-19 mg/L). The study showed that N/P ratio has a crucial effect on the biomass growth and nutrient removal. When N/P=10, a complete P and N removal was achieved at the end of cultivation with specific growth rate (SGR) of 1 d -1 and biomass concentration of 1.58 g/L. It was also observed that when the N content <2.5 mg/L, the SGR significantly reduced from 1.04 to 0.23 d -1 and the maximum biomass produced was decreased more than three-fold to 0.5 g/L. The Box-Behnken experimental design and response surface method were used to study the effects of the initial concentrations (P, N and C) on P and N removal efficiencies. The optimized P, N and C concentrations supporting 100% removal of both P and N at an SGR of 0.95 were 7, 55 and 10 mg/L respectively, with desirability value of 0.94. The results and analysis obtained could be very useful when applying the microalgae for efficient wastewater treatment and nutrient removal.
Gutiérrez-Martínez, Maria del Rosario; Muñoz-Guerrero, Hernán; Alcaína-Miranda, Maria Isabel; Barat, José Manuel
2014-03-01
The salting step in food processes implies the production of large quantities of waste brines, having high organic load, high conductivity, and other pollutants with high oxygen demand. Direct disposal of the residual brine implies salinization of soil and eutrophication of water. Since most of the organic load of the waste brines comes from proteins leaked from the salted product, precipitation of dissolved proteins by acidification and removal by centrifugation is an operation to be used in waste brine cleaning. The aim of this study is optimizing the conditions for carrying out the separation of proteins from waste brines generated in the pork ham salting operation, by studying the influence of pH, centrifugal force, and centrifugation time. Models for determining the removal of proteins depending on the pH, centrifugal force, and time were obtained. The results showed a high efficacy of the proposed treatment for removing proteins, suggesting that this method could be used for waste brine protein removal. The best pH value to be used in an industrial process seems to be 3, while the obtained results indicate that almost 90% of the proteins from the brine can be removed by acidification followed by centrifugation. A further protein removal from the brine should have to be achieved using filtrating techniques, which efficiency could be highly improved as a consequence of the previous treatment through acidification and centrifugation. Waste brines from meat salting have high organic load and electrical conductivity. Proteins can be removed from the waste brine by acidification and centrifugation. The total protein removal can be up to 90% of the initial content of the waste brine. Protein removal is highly dependent on pH, centrifugation rate, and time. © 2014 Institute of Food Technologists®
Sheludchenko, Maxim; Padovan, Anna; Katouli, Mohammad; Stratton, Helen
2016-01-01
Maturation ponds are used in rural and regional areas in Australia to remove the microbial loads of sewage wastewater, however, they have not been studied intensively until present. Using a combination of culture-based methods and quantitative real-time PCR, we assessed microbial removal rates in maturation ponds at four waste stabilization ponds (WSP) with (n = 1) and without (n = 3) baffles in rural and remote communities in Australia. Concentrations of total coliforms, E. coli, enterococci, Campylobacter spp., Salmonella spp., F+ RNA coliphage, adenovirus, Cryptosporidium spp. and Giardia (oo) cysts in maturation ponds were measured at the inlet and outlet. Only the baffled pond demonstrated a significant removal of most of the pathogens tested and therefore was subjected to further study by analyzing E. coli and enterococci concentrations at six points along the baffles over five sampling rounds. Using culture-based methods, we found a decrease in the number of E. coli and enterococci from the initial values of 100,000 CFU per 100 mL in the inlet samples to approximately 1000 CFU per 100 mL in the outlet samples for both bacterial groups. Giardia cysts removal was relatively higher than fecal indicators reduction possibly due to sedimentation. PMID:26729150
Sheludchenko, Maxim; Padovan, Anna; Katouli, Mohammad; Stratton, Helen
2016-01-02
Maturation ponds are used in rural and regional areas in Australia to remove the microbial loads of sewage wastewater, however, they have not been studied intensively until present. Using a combination of culture-based methods and quantitative real-time PCR, we assessed microbial removal rates in maturation ponds at four waste stabilization ponds (WSP) with (n = 1) and without (n = 3) baffles in rural and remote communities in Australia. Concentrations of total coliforms, E. coli, enterococci, Campylobacter spp., Salmonella spp., F+ RNA coliphage, adenovirus, Cryptosporidium spp. and Giardia (oo) cysts in maturation ponds were measured at the inlet and outlet. Only the baffled pond demonstrated a significant removal of most of the pathogens tested and therefore was subjected to further study by analyzing E. coli and enterococci concentrations at six points along the baffles over five sampling rounds. Using culture-based methods, we found a decrease in the number of E. coli and enterococci from the initial values of 100,000 CFU per 100 mL in the inlet samples to approximately 1000 CFU per 100 mL in the outlet samples for both bacterial groups. Giardia cysts removal was relatively higher than fecal indicators reduction possibly due to sedimentation.
Sharif, Fariya; Westerhoff, Paul; Herckes, Pierre
2014-02-01
Constructed wetlands remove trace organic contaminants via synergistic processes involving plant biomass that include hydrolysis, volatilization, sorption, biodegradation, and photolysis. Wetland design conditions, such as hydraulic loading rates (HLRs) and carbon loading rates (CLRs), influence these processes. Contaminant of emerging concern (CEC) removal by wetland plants was investigated at varying HLRs and CLRs. Rate constants and parameters obtained from batch-scale studies were used in a mechanistic model to evaluate the effect of these two loading rates on CEC removal. CLR significantly influenced CEC removal when wetlands were operated at HLR >5 cm/d. High values of CLR increased removal of estradiol and carbamazepine but lowered that of testosterone and atrazine. Without increasing the cumulative HLR, operating two wetlands in series with varying CLRs could be a way to improve CEC removal. Copyright © 2013 Elsevier Ltd. All rights reserved.
Arsenic remediation of drinking water using iron-oxide coated coal bottom ash
DOE Office of Scientific and Technical Information (OSTI.GOV)
MATHIEU, JOHANNA L.; GADGIL, ASHOK J.; ADDY, SUSAN E.A.
2010-06-01
We describe laboratory and field results of a novel arsenic removal adsorbent called 'Arsenic Removal Using Bottom Ash' (ARUBA). ARUBA is prepared by coating particles of coal bottom ash, a waste material from coal fired power plants, with iron (hydr)oxide. The coating process is simple and conducted at room temperature and atmospheric pressure. Material costs for ARUBA are estimated to be low (~;;$0.08 per kg) and arsenic remediation with ARUBA has the potential to be affordable to resource-constrained communities. ARUBA is used for removing arsenic via a dispersal-and-removal process, and we envision that ARUBA would be used in community-scale watermore » treatment centers. We show that ARUBA is able to reduce arsenic concentrations in contaminated Bangladesh groundwater to below the Bangladesh standard of 50 ppb. Using the Langmuir isotherm (R2 = 0.77) ARUBA's adsorption capacity in treating real groundwater is 2.6x10-6 mol/g (0.20 mg/g). Time-to-90percent (defined as the time interval for ARUBA to remove 90percent of the total amount of arsenic that is removed at equilibrium) is less than one hour. Reaction rates (pseudo-second-order kinetic model, R2>_ 0.99) increase from 2.4x105 to 7.2x105 g mol-1 min-1 as the groundwater arsenic concentration decreases from 560 to 170 ppb. We show that ARUBA's arsenic adsorption density (AAD), defined as the milligrams of arsenic removed at equilibrium per gram of ARUBA added, is linearly dependent on the initial arsenic concentration of the groundwater sample, for initial arsenic concentrations of up to 1600 ppb and an ARUBA dose of 4.0 g/L. This makes it easy to determine the amount of ARUBA required to treat a groundwater source when its arsenic concentration is known and less than 1600 ppb. Storing contaminated groundwater for two to three days before treatment is seen to significantly increase ARUBA's AAD. ARUBA can be separated from treated water by coagulation and clarification, which is expected to be less expensive than filtration of micron-scale particles, further contributing to the affordability of a community-scale water treatment center.« less
Yoon, Hongkyu; Oostrom, Mart; Wietsma, Thomas W; Werth, Charles J; Valocchi, Albert J
2009-10-13
The purpose of this work is to identify the mechanisms that govern the removal of carbon tetrachloride (CT) during soil vapor extraction (SVE) by comparing numerical and analytical model simulations with a detailed data set from a well-defined intermediate-scale flow cell experiment. The flow cell was packed with a fine-grained sand layer embedded in a coarse-grained sand matrix. A total of 499 mL CT was injected at the top of the flow cell and allowed to redistribute in the variably saturated system. A dual-energy gamma radiation system was used to determine the initial NAPL saturation profile in the fine-grained sand layer. Gas concentrations at the outlet of the flow cell and 15 sampling ports inside the flow cell were measured during subsequent CT removal using SVE. Results show that CT mass was removed quickly in coarse-grained sand, followed by a slow removal from the fine-grained sand layer. Consequently, effluent gas concentrations decreased quickly at first, and then started to decrease gradually, resulting in long-term tailing. The long-term tailing was mainly due to diffusion from the fine-grained sand layer to the coarse-grained sand zone. An analytical solution for a one-dimensional advection and a first-order mass transfer model matched the tailing well with two fitting parameters. Given detailed knowledge of the permeability field and initial CT distribution, we were also able to predict the effluent concentration tailing and gas concentration profiles at sampling ports using a numerical simulator assuming equilibrium CT evaporation. The numerical model predictions were accurate within the uncertainty of independently measured or literature derived parameters. This study demonstrates that proper numerical modeling of CT removal through SVE can be achieved using equilibrium evaporation of NAPL if detailed fine-scale knowledge of the CT distribution and physical heterogeneity is incorporated into the model. However, CT removal could also be fit by a first-order mass transfer analytical model, potentially leading to an erroneous conclusion that the long-term tailing in the experiment was kinetically controlled due to rate-limited NAPL evaporation.
Eden, John-Sebastian; Read, Andrew J.; Duckworth, Janine A.; Strive, Tanja
2015-01-01
To resolve the evolutionary history of rabbit hemorrhagic disease virus (RHDV), we performed a genomic analysis of the viral stocks imported and released as a biocontrol measure in Australia, as well as a global phylogenetic analysis. Importantly, conflicts were identified between the sequences determined here and those previously published that may have affected evolutionary rate estimates. By removing likely erroneous sequences, we show that RHDV emerged only shortly before its initial description in China. PMID:26378178
Biological Utilization of Wood for Production of Chemicals and Foodstuffs.
1981-03-01
ration and, corn . The results are presented in of lambs. As high as 20 percent of although the cost of gains on the table 50. The results of the...differs in that, after an initial 185 ° C. At this time, most of the low- Residues high in bark reduce the period of low-temperature hydrolysis...and hydrolyzate is removed at the per part of the chip bed. The high table 6. bottom with no interruptions until the through-put rate is continued until
Yang, Zhao; Gong, Xiao-Bo; Peng, Lin; Yang, Dan; Liu, Yong
2018-06-04
A novel Zn 0 -CNTs-Fe 3 O 4 composite was synthesized by the chemical co-precipitation combined with high sintering process at nitrogen atmosphere. The as-prepared composite was characterized by SEM, EDS, XRD, XPS, VSM and N 2 adsorption/desorption experiments. A novel heterogeneous Fenton-like system, composed of Zn 0 -CNTs-Fe 3 O 4 composite and dissolved oxygen (O 2 ) in solution, which can in situ generate H 2 O 2 and OH, was used for the degradation of 4-chlorophenol (4-CP). The influences of various operational parameters, including the initial pH, dosage of Zn 0 -CNTs-Fe 3 O 4 and initial concentration of 4-CP on the removal of 4-CP were investigated. The removal efficiencies of 4-CP and total organic carbon (TOC) were 99% and 57%, respectively, at the initial pH of 1.5, Zn 0 -CNTs-Fe 3 O 4 dosage of 2 g/L, 4-CP initial concentration of 50 mg/L and oxygen flow rate of 400 mL/min. Based on the results of the radical scavenger effect study, the hydroxyl radical was considered as the main reactive oxidants in Zn 0 -CNTs-Fe 3 O 4 /O 2 system and a possible degradation pathway of 4-CP was proposed. Copyright © 2018. Published by Elsevier Ltd.
Alkali, thermo and halo tolerant fungal isolate for the removal of textile dyes.
Kaushik, Prachi; Malik, Anushree
2010-11-01
In the present study potential of a fungal isolate Aspergillus lentulusFJ172995, was investigated for the removal of textile dyes. The removal percentages of dyes such as Acid Navy Blue, Orange-HF, Fast Red A, Acid Sulphone Blue and Acid Magenta were determined as 99.43, 98.82, 98.75, 97.67 and 69.98, respectively. None of the dyes inhibited the growth of A. lentulus. Detailed studies on growth kinetics, mechanism of dye removal and effect of different parameters on dye removal were conducted using Acid Navy Blue dye. It was observed that A. lentulus could completely remove Acid Navy Blue even at high initial dye concentrations, up to 900 mg/L. Highest uptake capacity of 212.92 mg/g was observed at an initial dye concentration of 900 mg/L. Dye removing efficiency was not altered with the variation of pH; and biomass production as well as dye removal was favored at higher temperatures. Dye removal was also efficient even at high salt concentration. Through growth kinetics studies it was observed that the initial exponential growth phase coincided with the phase of maximal dye removal. Microscopic studies suggest that bioaccumulation along with biosorption is the principle mechanism involved in dye removal by A. lentulus. Thus, it is concluded that being alkali, thermo and halo tolerant, A. lentulus isolate has a great potential to be utilized for the treatment of dye bearing effluents which are usually alkaline, hot and saline. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Optimization of Photooxidative Removal of Phenazopyridine from Water
NASA Astrophysics Data System (ADS)
Saeid, Soudabeh; Behnajady, Mohammad A.; Tolvanen, Pasi; Salmi, Tapio
2018-05-01
The photooxidative removal of analgesic pharmaceutical compound phenazopyridine (PhP) from aqueous solutions by UV/H2O2 system with a re-circulated photoreactor was investigated. Response surface methodology (RSM) was employed to optimize the effect of operational parameters on the photooxidative removal efficiency. The investigated variables were: the initial PhP and H2O2 concentrations, irradiation time, volume of solution and pH. The analysis of variance (ANOVA) of quadratic model demonstrated that the described model was highly significant. The predicted values of the photooxidative removal efficiency were found to be in a fair agreement with experimental values ( R 2 = 0.9832, adjusted R 2 = 0.9716). The model predicted that the optimal reaction conditions for a maximum removal of PhP (>98%) were: initial PhP concentration less than 23 mg L-1, initial concentration of H2O2 higher than 470 mg L-1, solution volume less than 500 mL, pH close to 2 and irradiation time longer than 6 min.
Photocatalytic Treatment of a Synthetic Wastewater
NASA Astrophysics Data System (ADS)
Yerkinova, Azat; Balbayeva, Gaukhar; Inglezakis, Vassilis J.; Poulopoulos, Stavros G.
2018-01-01
This work aimed at investigating the photocatalytic treatment of a synthetic wastewater using UV light (254 nm, 6 W), TiO2 catalyst and H2O2 in a batch recycle annular photoreactor. The total volume of the solution was 250 mL while the irradiated volume in the annular photoreactor with 55.8 mL. Each experiment lasted 120 min and samples were sent for Total Carbon and HPLC analysis. The stock wastewater had initial total carbon 1118 mg L-1. The effect of the presence of phenol in the wastewater on total carbon (TC) removal was also studied. It was shown that the photocatalytic treatment was effective only when initial TC was decreased to 32 mg L-1, whereas the optimum TiO2 concentration was 0.5 g L-1, leading to a TC removal up to 56%. For the same initial carbon load, the optimum H2O2 concentration was found to be 67 mg L-1 resulting in 55% TC removal. Combining, however, TiO2 and H2O2 did not lead to better performance, as 51% TC removal was observed. In contrast, when initial carbon in the wastewater was partially substituted by phenol, the combination of catalyst and hydrogen peroxide was beneficial. Specifically, when 10 ppm of phenol were added keeping the same initial TC concentration, UV/TiO2 treatment resulted in 46% TC removal and 98% phenol conversion, whereas using additionally H2O2 led to 100% phenol conversion after 45 minutes and 81% TC removal.
Espejo, Azahara; Aguinaco, Almudena; García-Araya, J F; Beltrán, Fernando J
2014-01-01
Sequential treatments consisting in a chemical process followed by a conventional biological treatment, have been applied to remove mixtures of nine contaminants of pharmaceutical type spiked in a primary sedimentation effluent of a municipal wastewater. Combinations of ozone, UVA black light (BL) and Fe(III) or Fe₃O₄ catalysts constituted the chemical systems. Regardless of the Advanced Oxidation Process (AOP), the removal of pharmaceutical compounds was achieved in 1 h of reaction, while total organic carbon (TOC) only diminished between 3.4 and 6%. Among selected ozonation systems to be implemented before the biological treatment, the application of ozone alone in the pre-treatment stage is recommended due to the increase of the biodegradability observed. The application of ozone followed by the conventional biological treatment leads high TOC and COD removal rates, 60 and 61%, respectively, and allows the subsequent biological treatment works with shorter hydraulic residence time (HRT). Moreover, the influence of the application of AOPs before and after a conventional biological process was compared, concluding that the decision to take depends on the characterization of the initial wastewater with pharmaceutical compounds.
Effective removal of hydrogen sulfide using 4A molecular sieve zeolite synthesized from attapulgite.
Liu, Xinpeng; Wang, Rui
2017-03-15
In this work, 4A molecular sieve zeolite was synthesized from attapulgite (ATP) in different conditions and was applied initially for H 2 S removal. The sorbent was characterized by scanning electron microscopy, X-ray diffraction, Fourier transform infrared spectra and N 2 adsorption/desorption. The effects of the synthesis condition and adsorption temperature were studied by dynamic adsorption experiment. The optimal adsorption temperature is 50°C. The H 2 S adsorption results have showed that the optimal synthesis conditions are as follows: the ratio of silicon to aluminum and ratio of sodium to silicon are both 1.5, the ratio of water to sodium is 30, crystallization temperature and crystallization time is 90°C, 4h, respectively. The breakthrough and saturation sulfur sorption capacities of zeolite synthesized under optimum conditions are up to nearly 10 and 15mg/g-sorbent, respectively, and the H 2 S removal rate is nearly 100%. The adsorption kinetics nonlinear fitting results show that the adsorption system follows Bingham model. These results indicate that 4A molecular sieve zeolite synthesized from attapulgite can be used for H 2 S removal promisingly. Copyright © 2016 Elsevier B.V. All rights reserved.
Björk-Shiley strut fracture and disc escape: literature review and a method of disc retrieval.
Hendel, P N
1989-03-01
Embolization of a prosthetic valve poppet is a rare but life-threatening event. It was reported sporadically before the introduction of the Björk-Shiley 70-degree convexoconcave prosthesis in 1980. Since that time, there have been a large number of reported mechanical failures with disc escape. The rate for the 29-mm to 33-mm mitral valves is estimated as 5.2%. In 29 of 35 patients (including the 2 presented here) in whom the site of disc lodgment could be determined, the disc was in the descending or abdominal aorta. Fifteen of these patients died. Six survivors had the disc removed at the same operation and 6 at a later operation. In 2 patients, the disc was not removed. In 2 patients in whom the disc was not removed initially, it was thought to contribute to postoperative complications. Two more cases of structural failure of the Björk-Shiley convexoconcave prosthesis are presented. A transpericardial approach to the descending aorta on bypass is described. It allows easy removal of the disc and eliminates the need for a second operation.
Escolà Casas, Mònica; Nielsen, Tue Kjærgaard; Kot, Witold; Hansen, Lars Hestbjerg; Johansen, Anders; Bester, Kai
2017-09-15
Mecoprop is a common pollutant in effluent-, storm- and groundwater as well as in leachates from derelict dumpsites. Thus, bioremediation approaches may be considered. We conducted batch experiments with moving bed biofilm (MBBR)-carriers to understand the degradation of mecoprop. As a model, the carriers were incubated in effluent from a conventional wastewater treatment plant which was spiked to 10, 50 and 100 μg L -1 mecoprop. Co-metabolic processes as well as mineralization were studied. Initial mecoprop concentration and mecoprop degradation impacted the microbial communities. The removal of (S)-mecoprop prevailed over the (R)-mecoprop. This was associated with microbial compositions, in which several operational taxonomic units (OTUs) co-varied positively with (S)-mecoprop removal. The removal-rate constant of (S)-mecoprop was 0.5 d -1 in the 10 μg L -1 set-up but it decreased in the 50 and 100 μg L -1 set-ups. The addition of methanol prolonged the removal of (R)-mecoprop. During mecoprop degradation, 4-chloro-2-methylphenol was formed and degraded. A new metabolite (4-chloro-2-methylphenol sulfate) was identified and quantified. Copyright © 2017 Elsevier Ltd. All rights reserved.
Graphene and Graphene Derivatives for Pharmaceutical Residual Removal from Drinking Water
NASA Astrophysics Data System (ADS)
Yu, Ming; Zhang, Haifeng
Strategy to keeping pharmaceuticals out of the nation's water supplies is the most essential and long-term procedure, while improving effective filtering systems at water treatment plants or at resident home is more practical and efficient. Current techniques including oxidation/ozonation, activated carbons, and filtration using membranes are relatively efficient when the concentration of pharmaceutical residues in the aquatic ecosystem is high, while when the concentration is relatively low, no one effective technique can remove so many different pharmaceuticals. To overcome such significant limitation, we are seeking to develop graphene based materials for pharmaceutical residual removal from drinking water and to initiate the study on dealing with this issue through fundamental understanding. Our results have shown that the graphene/graphene derivate could possess high adsorption rate to pharmaceutical residues (e.g., estradiol), promising their potential applications for pharmaceutical contamination removal from drinking water. Detailed information about the activities of the graphene with a variety of biomolecules, the type of adsorptions, and the effects of the attached hydroxyl, epoxyl, and carboxyl functional groups will be presented in the Meeting. The authors acknowledge computing resource support from the Cardinal Research Cluster at the University of Louisville.
Emissions of NO and N2O in wetland microcosms for swine wastewater treatment.
Zhang, Shunan; Liu, Feng; Xiao, Runlin; Li, Yong; Zhou, Juan; Wu, Jinshui
2015-12-01
Nitric oxide (NO) and nitrous oxide (N2O) emitted from wetland systems contribute an important proportion to the global warming effect. In this study, four wetland microcosms vegetated with Myriophyllum elatinoides (WM), Alternanthera philoxeroides (WA), Eichhornia crassipes (WE), or without vegetation (NW) were compared to investigate the emissions of NO and N2O during nitrogen (N) removal process when treating swine wastewater. After 30-day incubation, TN removal rates of 96.4, 74.2, 97.2, and 47.3 % were observed for the WM, WA, WE, and NW microcosms, respectively. Yet, no significant difference was observed in WM and WE (p > 0.05). The average NO and N2O emissions in WE was significantly higher than those in WM, WA, and NW (p < 0.05). In addition, the emission of N2O in WE accounted for 2.10 % of initial TN load and 2.17 % of the total amount of TN removal, compared with less than 1 % in the other microcosms. These findings indicate that wetland vegetated with M. elatinoides may be an optimal system for swine wastewater treatment, based on its higher removal of N and lower emissions of NO and N2O.
Tao, Tao; Zhang, Ming; Zhang, Qi-Jie; Li, Liang; Li, Tao; Zhu, Xiao; Li, Ming-Dong; Li, Gui-Hua; Sun, Shu-Xia
2017-01-01
AIM To compare the efficacy of a session of extracorporeal shock wave lithotripsy (ESWL) before endoscopic retrograde cholangiopancreatography (ERCP) vs ERCP only for problematic and large common bile duct (CBD) stones. METHODS Adult patients with CBD stones for whom initial ERCP was unsuccessful because of the large size of CBD stones were identified. The patients were randomized into two groups, an “ESWL + ERCP group” and an “ERCP-only” group. For ESWL + ERCP cases, ESWL was performed prior to ERCP. Clearance of the CBD, complications related to the ESWL/ERCP procedure, frequency of mechanical lithotripsy use and duration of the ERCP procedure were evaluated in both groups. RESULTS There was no significant difference in baseline characteristics between the two groups. A session of ESWL before ERCP compared with ERCP only resulted in similar outcomes in terms of successful stone removal within the first treatment session (74.2% vs 71.0%, P = 0.135), but a higher clearance rate within the second treatment session (84.4% vs 51.6%, P = 0.018) and total stone clearance (96.0% vs 86.0%, P = 0.029). Moreover, ESWL prior to ERCP not only reduced ERCP procedure time (43 ± 21 min vs 59 ± 28 min, P = 0.034) and the rate of mechanical lithotripsy use (20% vs 30%, P = 0.025), but also raised the clearance rate of extremely large stones (80.0% vs 40.0%, P = 0.016). Post-ERCP complications were similar for the two groups. CONCLUSION Based on the higher rate of successful stone removal and minimal complications, ESWL prior to ERCP appears to be a safe and effective treatment for the endoscopic removal of problematic and large CBD stones. PMID:28785149
Effect of loss control service on reported injury incidence.
Nave, Michael E; Veltri, Anthony
2004-01-01
A retrospective analysis evaluated the effectiveness of an insurance carrier's flexible loss control service strategy in reducing workers' compensation policyholders' reported injury and illness claims. To assess the effects of a loss control service strategy on workers' compensation claim frequency rates, on medical-only claim rates, on severity-claim rates, and on claim cost among a group of California employers. Eighty-two small- and medium-sized companies with workers' compensation policies expiring in 1999 were randomly selected from a population of policyholders assigned to loss control consultants for two or more years. Claim performance data were obtained for each company's first expired in-force policy year and its 1999 expired policy year. The retrospective design was combined with a control component based on a randomly selected comparison group of 45 companies whose first policy year with the insurer expired in 1999 and who received safety services from the loss control staff. The flexible loss control consultation service strategy was associated with lower average claim rates and costs. Companies assigned to a loss control consultant for two or more years (the "outcome group") had an average claim rate of 1.24 per $10,000 premium, compared with a rate of 1.62 in the "initial group" and a rate of 1.60 in the "comparison group." The average severity-claim rate of the outcome group was 0.32, compared with the initial-year and comparison-group means of 0.48 and 0.46, respectively. The average medical-only claim rate was 0.92, compared with the initial- and comparison-group means of 1.14 and 1.14. The outcome group's average loss ratio was over 10% lower than that of the initial and comparison groups. Statistical analysis indicated that differences among the groups' claim rates and severity-claim rates were [F=(2,206) 4.938, P=0.008] and [F=(2,206) 8.208, P<0.001], respectively. A loss control service strategy that provides service flexibility and develops partnership between employer and consultant can help reduce the frequency and severity of workers' compensation claims. Barriers to consultation service flexibility, both internal and external, should be identified and removed to enhance service efficacy.
Geomorphic and habitat response to a large-dam removal in a Mediterranean river
NASA Astrophysics Data System (ADS)
Harrison, L.; East, A. E.; Smith, D. P.; Bond, R.; Logan, J. B.; Nicol, C.; Williams, T.; Boughton, D. A.; Chow, K.
2017-12-01
The presence of large dams has fundamentally altered physical and biological processes in riverine ecosystems, and dam removal is becoming more common as a river restoration strategy. We used a before-after-control-impact study design to investigate the geomorphic and habitat response to removal of 32-m-high San Clemente Dam on the Carmel River, CA. The project represents the first major dam removal in a Mediterranean river and is also unique among large dam removals in that most reservoir sediment was sequestered in place. We found that in the first year post-removal, a sediment pulse migrated 3.5 km downstream, filling pools and the interstitial pore spaces of gravels with sand. These sedimentary and topographic changes initially reduced the overall quality of steelhead (O. mykiss) spawning and rearing habitat in impacted reaches. Over the second winter after dam removal, a sequence of high flows flushed large volumes of sand from pools and mobilized the river bed throughout much of the active channel. The floods substantially altered fluvial evolution in the upper part of the reservoir, promoting new avulsion and the subsequent delivery of gravel and large wood to below dam reaches. These geomorphic processes increased the availability of spawning-sized gravel and enhanced channel complexity in reaches within several km of the former dam, which should improve habitat for multiple life stages of steelhead. Results indicate that when most reservoir sediment remains impounded, high flows become more important drivers of geomorphic and habitat change than dam removal alone. In such cases, the rates at which biophysical processes are reestablished will depend largely on post-dam removal flow sequencing and the upstream supply of sediment and large wood.
21 CFR 107.210 - Firm-initiated product removals.
Code of Federal Regulations, 2011 CFR
2011-04-01
... (CONTINUED) FOOD FOR HUMAN CONSUMPTION INFANT FORMULA Infant Formula Recalls § 107.210 Firm-initiated product removals. (a) If a manufacturer has determined to recall voluntarily from the market an infant formula that... this subpart. (b) If a manufacturer has determined to withdraw voluntarily from the market an infant...
21 CFR 107.210 - Firm-initiated product removals.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) FOOD FOR HUMAN CONSUMPTION INFANT FORMULA Infant Formula Recalls § 107.210 Firm-initiated product removals. (a) If a manufacturer has determined to recall voluntarily from the market an infant formula that... this subpart. (b) If a manufacturer has determined to withdraw voluntarily from the market an infant...
Foose, Ladan L; Blanch, Harvey W; Radke, C J
2009-03-01
Enzymatic degradation of immobilized ovalbumin multilayer films by subtilisin Carlsberg was investigated using in situ ellipsometry. Changes in the substrate cleavage rate in the presence of an anionic surfactant, sodium dodecylbenzene sulfonate (SDBS), were assessed. Exposure of the protein film to SDBS prior to introduction of the enzyme increased the measured proteolysis rate threefold. Surfactant increased the measured film thickness, absorbing into the protein film and causing swelling. Surfactant-induced film swelling was reversible upon aqueous rinsing. Nevertheless, exposure of enzyme to the surfactant-rinsed film increased the proteolysis rate, most likely due to irreversible conformational changes induced in the substrate film by the surfactant. Simultaneous addition of SDBS with enzyme after the initial surfactant exposure did not produce additional protein-removal benefit.
[Kinetics of catalytic wet air oxidation of phenol in trickle bed reactor].
Li, Guang-ming; Zhao, Jian-fu; Wang, Hua; Zhao, Xiu-hua; Zhou, Yang-yuan
2004-05-01
By using a trickle bed reactor which was designed by the authors, the catalytic wet air oxidation reaction of phenol on CuO/gamma-Al2O3 catalyst was studied. The results showed that in mild operation conditions (at temperature of 180 degrees C, pressure of 3 MPa, liquid feed rate of 1.668 L x h(-1) and oxygen feed rate of 160 L x h(-1)), the removal of phenol can be over 90%. The curve of phenol conversion is similar to "S" like autocatalytic reaction, and is accordance with chain reaction of free radical. The kinetic model of pseudo homogenous reactor fits the catalytic wet air oxidation reaction of phenol. The effects of initial concentration of phenol, liquid feed rate and temperature for reaction also were investigated.
Impact of HVAC filter on indoor air quality in terms of ozone removal and carbonyls generation
NASA Astrophysics Data System (ADS)
Lin, Chi-Chi; Chen, Hsuan-Yu
2014-06-01
This study aims at detecting ozone removal rates and corresponding carbonyls generated by ozone reaction with HVAC filters from various building, i.e., shopping mall, school, and office building. Studies were conducted in a small-scale environmental chamber. By examining dust properties including organic carbon proportion and specific surface area of dusts adsorbed on filters along with ozone removal rates and carbonyls generation rate, the relationship among dust properties, ozone removal rates, and carbonyls generation was identified. The results indicate a well-defined positive correlation between ozone removal efficiency and carbonyls generation on filters, as well as a positive correlation among the mass of organic carbon on filters, ozone removal efficiency and carbonyls generations.
Microstructural Evolution of Ti-6Al-4V during High Strain Rate Conditions of Metal Cutting
NASA Technical Reports Server (NTRS)
Dong, Lei; Schneider, Judy
2009-01-01
The microstructural evolution following metal cutting was investigated within the metal chips of Ti-6Al-4V. Metal cutting was used to impose a high strain rate on the order of approx.10(exp 5)/s within the primary shear zone as the metal was removed from the workpiece. The initial microstructure of the parent material (PM) was composed of a bi-modal microstructure with coarse prior grains and equiaxed primary located at the boundaries. After metal cutting, the microstructure of the metal chips showed coarsening of the equiaxed primary grains and lamellar. These metallographic findings suggest that the metal chips experienced high temperatures which remained below the transus temperature.
Barnacles resist removal by crack trapping
Hui, Chung-Yuen; Long, Rong; Wahl, Kathryn J.; Everett, Richard K.
2011-01-01
We study the mechanics of pull-off of a barnacle adhering to a thin elastic layer which is bonded to a rigid substrate. We address the case of barnacles having acorn shell geometry and hard, calcarious base plates. Pull-off is initiated by the propagation of an interface edge crack between the base plate and the layer. We compute the energy release rate of this crack as it grows along the interface using a finite element method. We also develop an approximate analytical model to interpret our numerical results and to give a closed-form expression for the energy release rate. Our result shows that the resistance of barnacles to interfacial failure arises from a crack-trapping mechanism. PMID:21208968
Assessing Chemical Retention Process Controls in Ponds
NASA Astrophysics Data System (ADS)
Torgersen, T.; Branco, B.; John, B.
2002-05-01
Small ponds are a ubiquitous component of the landscape and have earned a reputation as effective chemical retention devices. The most common characterization of pond chemical retention is the retention coefficient, Ri= ([Ci]inflow-[Ci] outflow)/[Ci]inflow. However, this parameter varies widely in one pond with time and among ponds. We have re-evaluated literature reported (Borden et al., 1998) monthly average retention coefficients for two ponds in North Carolina. Employing a simple first order model that includes water residence time, the first order process responsible for species removal have been separated from the water residence time over which it acts. Assuming the rate constant for species removal is constant within the pond (arguable at least), the annual average rate constant for species removal is generated. Using the annual mean rate constant for species removal and monthly water residence times results in a significantly enhanced predictive capability for Davis Pond during most months of the year. Predictive ability remains poor in Davis Pond during winter/unstratified periods when internal loading of P and N results in low to negative chemical retention. Predictive ability for Piedmont Pond (which has numerous negative chemical retention periods) is improved but not to the same extent as Davis Pond. In Davis Pond, the rate constant for sediment removal (each month) is faster than the rate constant for water and explains the good predictability for sediment retention. However, the removal rate constant for P and N is slower than the removal rate constant for sediment (longer water column residence time for P,N than for sediment). Thus sedimentation is not an overall control on nutrient retention. Additionally, the removal rate constant for P is slower than for TOC (TOC is not the dominate removal process for P) and N is removed slower than P (different in pond controls). For Piedmont Pond, sediment removal rate constants are slower than the removal rate constant for water indicating significant sediment resuspension episodes. It appears that these sediment resuspension events are aperiodic and control the loading and the chemical retention capability of Piedmont Pond for N,P,TOC. These calculated rate constants reflect the differing internal loading processes for each component and suggest means and mechanisms for the use of ponds in water quality management.
Speaker diarization system on the 2007 NIST rich transcription meeting recognition evaluation
NASA Astrophysics Data System (ADS)
Sun, Hanwu; Nwe, Tin Lay; Koh, Eugene Chin Wei; Bin, Ma; Li, Haizhou
2007-09-01
This paper presents a speaker diarization system developed at the Institute for Infocomm Research (I2R) for NIST Rich Transcription 2007 (RT-07) evaluation task. We describe in details our primary approaches for the speaker diarization on the Multiple Distant Microphones (MDM) conditions in conference room scenario. Our proposed system consists of six modules: 1). Least-mean squared (NLMS) adaptive filter for the speaker direction estimate via Time Difference of Arrival (TDOA), 2). An initial speaker clustering via two-stage TDOA histogram distribution quantization approach, 3). Multiple microphone speaker data alignment via GCC-PHAT Time Delay Estimate (TDE) among all the distant microphone channel signals, 4). A speaker clustering algorithm based on GMM modeling approach, 5). Non-speech removal via speech/non-speech verification mechanism and, 6). Silence removal via "Double-Layer Windowing"(DLW) method. We achieves error rate of 31.02% on the 2006 Spring (RT-06s) MDM evaluation task and a competitive overall error rate of 15.32% for the NIST Rich Transcription 2007 (RT-07) MDM evaluation task.
Koolivand, Ali; Rajaei, Mohammad Sadegh; Ghanadzadeh, Mohammad Javad; Saeedi, Reza; Abtahi, Hamid; Godini, Kazem
2017-07-01
The effect of mixing ratio and nutrients addition on the efficiency of a two-stage composting system in removal of total petroleum hydrocarbons (TPH) from storage tank bottom sludge (STBS) was investigated. The system consisted of ten windrow piles as primary composting (PC) followed by four in-vessel reactors as secondary composting (SC). Various initial C/N/P and mixing ratios of STBS to immature compost (IC) were examined in the PC and SC for 12 and 6weeks, respectively. The removal rates of TPH in the two-stage system (93.72-95.24%) were higher than those in the single-stage one. Depending on the experiments, TPH biodegradation fitted to the first- and second-order kinetics with the rate constants of 0.051-0.334d -1 and 0.002-0.165gkg -1 d -1 , respectively. The bacteria identified were Pseudomonas sp., Bacillus sp., Klebsiella sp., Staphylococcus sp., and Proteus sp. The study verified that a two-stage composting system is effective in treating the STBS. Copyright © 2017 Elsevier Ltd. All rights reserved.
Lead recovery from waste CRT funnel glass by high-temperature melting process.
Hu, Biao; Hui, Wenlong
2018-02-05
In this research, a novel and effective process for waste CRT funnel glass treatment was developed. The key to this process is removal of lead from the CRT funnel glass by high-temperature melting process. Sodium carbonate powder was used as a fusion agent, sodium sulfide serves as a catalytic agent and carbon powder acts as reducing agent. Experimental results showed that lead recovery rate increased with an increase in the amount of added sodium carbonate, sodium sulfide, carbonate, temperature and holding time initially, and then reached a stable value. The maximum lead recovery rate was approximately 94%, when the optimum adding amount of sodium carbonate, sodium sulfide, carbonate, temperature and holding time were 25%, 8%, 3.6%, 1200°C and 120min, respectively. In the high-temperature melting process, lead silicate in the funnel glass was firstly reduced, and then removed. The glass slag can be made into sodium and potassium silicate by hydrolysis process. This study proposed a practical and economical process for recovery of lead and utilization of waste glass slag. Copyright © 2017 Elsevier B.V. All rights reserved.
The catalytic oxidation of malachite green by the microwave-Fenton processes.
Zheng, Huaili; Zhang, Huiqin; Sun, Xiaonan; Zhang, Peng; Tshukudu, Tiroyaone; Zhu, Guocheng
2010-01-01
Catalytic oxidation of malachite green using the microwave-Fenton process was investigated. 0% of malachite green de-colorization using the microwave process and 23.5% of malachite green de-colorization using the Fenton process were observed within 5 minutes. In contrast 95.4% of malachite green de-colorization using the microwave-Fenton was observed in 5 minutes. During the microwave-Fenton process, the optimum operating conditions for malachite green de-colorization were found to be 3.40 of initial pH, 0.08 mmol/L of Fe2+ concentration and 12.5 mmol/L of H2O2 concentration. Confirmatory tests were carried out under the optimum conditions and the COD removal rate of 82.0% and the de-colorization rate of 99.0% were observed in 5 minutes. The apparent kinetics equation of -dC/dt=0.0337 [malachite green]0.9860[Fe2+)]0.8234[H2O2]0.1663 for malachite green de-colorization was calculated, which implied that malachite green was the dominant factor in determining the removal efficiency of malachite green based on microwave-Fenton process.
Equilibrium and kinetic adsorption study of a cationic dye by a natural adsorbent--silkworm pupa.
Noroozi, B; Sorial, G A; Bahrami, H; Arami, M
2007-01-02
In this work the use of silkworm pupa, which is the waste of silk spinning industries has been investigated as an adsorbent for the removal of C.I. Basic Blue 41. The amino acid nature of the pupa provided a reasonable capability for dye removal. Equilibrium adsorption isotherms and kinetics were investigated. The adsorption equilibrium data were analyzed by using various adsorption isotherm models and the results have shown that adsorption behavior of the dye could be described reasonably well by either Langmuir or Freundlich models. The characteristic parameters for each isotherm have been determined. The monolayer adsorption capacity was determined to be 555 mg/g. Kinetic studies indicated that the adsorption follows pseudo-second-order kinetics with a rate constant of 0.0434 and 0.0572 g/min mg for initial dye concentration of 200 mg/l at 20 and 40 degrees C, respectively. Kinetic studies showed that film diffusion and intra-particle diffusion were simultaneously operating during the adsorption process. The rate constant for intra-particle diffusion was estimated to be 1.985 mg/g min(0.5).
Gianico, A; Braguglia, C M; Cesarini, R; Mininni, G
2013-09-01
The performance of thermophilic digestion of waste activated sludge, either untreated or thermal pretreated, was evaluated through semi-continuous tests carried out at organic loading rates in the range of 1-3.7 kg VS/m(3)d. Although the thermal pretreatment at T=134 °C proved to be effective in solubilizing organic matter, no significant gain in organics degradation was observed. However, the digestion of pretreated sludge showed significant soluble COD removal (more than 55%) whereas no removal occurred in control reactors. The lower the initial sludge biodegradability, the higher the efficiency of thermal pretreated digestion was observed, in particular as regards higher biogas and methane production rates with respect to the parallel untreated sludge digestion. Heat balance of the combined thermal hydrolysis/thermophilic digestion process, applied on full-scale scenarios, showed positive values for direct combustion of methane. In case of combined heat and power generation, attractive electric energy recoveries were obtained, with a positive heat balance at high load. Copyright © 2013. Published by Elsevier Ltd.
A less invasive surgical concept for the resection of spinal meningiomas.
Boström, A; Bürgel, U; Reinacher, P; Krings, T; Rohde, V; Gilsbach, J M; Hans, F J
2008-06-01
The surgical strategy for spinal meningiomas usually consists of laminectomy, initial tumour debulking, identification of the interface between tumour and spinal cord, resection of the dura including the matrix of the tumour, and duroplasty. The objective of this study was to investigate whether a less invasive surgical strategy consisting of hemilaminectomy or laminectomy, tumour removal and coagulation of the tumour matrix allows comparable surgical and clinical results to be obtained, especially without an increase of the recurrence rate as reported in the literature. Between 1990 and 2005, 61 patients (11 men, 50 women) underwent surgery for spinal meningioma. All patients were treated microsurgically by a posterior approach. In 56 of the 61 patients, the above outlined - less invasive - surgical technique with tumour removal and coagulation of the tumour matrix was performed. In 5 patients, dura resection and duroplasty was additionally performed. Electrophysiological monitoring was routinely used since 1996. Recurrence was defined as new onset or worsening of symptoms and radiological confirmation of tumour growth. The pre-and post-operative clinical status was measured by the Frankel grading system. Pre-operatively, 40 patients were in Frankel grade D, 13 patients in grade C, 6 patients in grade E and 1 patient each in grade A and B. Following surgery no patient presented a permanent worsening of clinical symptoms. All patients who initially presented with a Frankel grades A-C (n = 15) recovered to a better grade at the time of follow-up. Patients who presented with Frankel grade D remained in stable condition (n = 27) or recovered to a better neurological status (n = 13). Two patients experienced a temporary worsening of their symptoms, but subsequently improved to a better state than pre-operatively. Two (3.3%) complications (pseudomeningocele, wound infection) requiring surgery, were encountered. The pseudomeningocele developed in a patient who underwent durotomy. During the follow-up period of 2 months to 10 years (mean 31.3 months), 3 patients (5%) required surgery for symptomatic recurrence: 1 patient had 2 recurrences that occurred 4 and 7 years after first tumour removal and matrix coagulation, 1 recurrence occurred 1 year after tumour removal that was accompanied by matrix coagulation in a patient with a diffuse anterocranial tumour extension and 1 occurred 3 years after tumour removal and durotomy. Two patients showed a small recurrence on MRI during follow-up after 2 and 5 years, respectively, without any symptoms requiring surgery. The high rate of favourable clinical results combined with the low rate of recurrences supports our less invasive surgical concept, which does not aim for resection of the dural matrix of the spinal meningioma.
Dental hard tissue modification and removal using sealed TEA lasers operating at λ=9.6 and 10.6 μm
NASA Astrophysics Data System (ADS)
Fried, Daniel; Murray, Michael W.; Featherstone, John D. B.; Akrivou, Maria; Dickenson, Kevin M.; Duhn, Clifford W.; Ojeda, Orlando P.
1999-05-01
Pulsed CO2 lasers have been shown to be effective for both removal and modification of dental hard tissue for the treatment of dental caries. In this study, sealed TEA laser systems optimally tuned to the highly absorbed 9.6 μm wavelength were investigated for application on dental hard tissue. Conventional TEA lasers produce a laser pulse wit a 100-200 ns gain switched spike followed by a long tail of about 1-4 μs in duration. the pulse duration is well matched to the 1-2 μs thermal relaxation time of the deposited laser energy at 9.6 μm and effectively heats the enamel to temperatures required for surface modification for caries prevention at absorbed fluences of less than 0.5 J/cm2. Thus, the heat deposition in the tooth and the corresponding risk, of pulpal necrosis form excessive heat accumulation is minimized. At higher fluences the high peak power of the gain-switched spike rapidly initiates a plasma that markedly reduces the ablation rate and efficiency, severely limiting applicability for hard tissue ablation. By slightly stretching the pulse to reduce the energy distributed in the initial 100-200 ns of the laser pulse, the plasma threshold can be raised sufficiently to increase the ablation rate by an order of magnitude. This results in a practical and efficient CO2 laser system for caries ablation and surface modification.
NASA Astrophysics Data System (ADS)
Wang, Xuejiang; Song, Jingke; Huang, Jiayu; Zhang, Jing; Wang, Xin; Ma, RongRong; Wang, Jiayi; Zhao, Jianfu
2016-12-01
Magnetic photocatalyst - iodine and nitrogen codoped TiO2 based on chitosan decorated magnetic activated carbon (I-N-T/CMAC) was prepared via simple coprecipitation and sol-gel method. The characteristics of photocatalysts were investigated by X-ray diffraction (XRD), N2 adsorption-desorption isotherm, field emission scanning electron microscopy (FESEM), energy dispersive spectrometry (EDS), fourier transform infrared (FTIR), X-ray photoelectron spectroscopy (XPS), UV-vis diffuse reflection spectroscopy (UV-vis DRS), photoluminescence (PL) spectroscopy and vibrating sample magnetometer (VSM). It turned out that the prepared material had large surface area, enhanced absorption of visible light, and magnetically separable properties when mole ratio of I/Ti was 0.1. Iodine-nitrogen codoped magnetic photocatalyst was used for the removal of salicylic acid (SA), and the rate of adsorption reaction for SA by I0.1-N-T/CMAC followed the pseudo second-order kinetic. Under visible light irradiation, 89.71% SA with initial concentration = 30 mg/L could be removed by I0.1-N-T/CMAC, and photodegradation rate of SA on I0.1-N-T/CMAC composites was 0.0084 min-1 which is about 4 times higher than that of magnetic photocatalyst with nitrogen doped only. The effects of SA initial concentration, pH, coexisting anions and humic acid to the degradation of SA with the prepared material were also investigated. Main oxidative species in the photodegradation process are rad OH and h+.
Amiri, Mohammad Javad; Abedi-Koupai, Jahangir; Eslamian, Saeid
2017-07-01
In this research, ostrich bone ash (OBA) was modified with nanoscale zerovalent iron (nZVI) particles and applied as a novel composite adsorbent (OBA/nZVI) for dynamic adsorption/reduction of Hg(II) and Pb(II) ions in a fixed-bed column system. Entrapment of nZVI in OBA beads barricades the particles from oxidation and aggregation. The dynamic behavior of metal ions removal by OBA/nZVI was assessed as a function of inlet flow rates, bed height, initial pollutants concentration and pH. The synthesized OBA/nZVI composite was characterized by several physicochemical techniques. Increase in pH and bed height and decrease in flow rates and initial metal concentration resulted in delay of breakthrough time. OBA breakthrough profile is sharper than the OBA/nZVI breakthrough curve for both metal ions and the breakthrough times increase in the order OBA/nZVI-Hg(II) > OBA/nZVI-Pb(II) > OBA-Pb(II) > OBA-Hg(II). Based on the experiment results, redox reaction is expected to occur to a certain extent, as the standard reduction potentials of Hg(II) and Pb(II) are more than that of Fe(II). From a practical point of view, the OBA/nZVI could be applied as a material to remove Hg(II) and Pb(II) ions from natural surface and ground water with a pH value of 5-9.
Akbari Shahabi, Zeinab; Naeimpoor, Fereshteh
2014-06-01
Heterotrophic denitrification of drinking water was enhanced by selection of an anoxic sludge taken from a dairy industry among the sludges taken from various industries, and the effect of carbon sources was examined. Acclimatization to high nitrate concentration was then carried out in a five-stage process. Considering removals of both nitrate and nitrite, the sludge taken from anoxic unit of Tehran Pegah dairy industry was shown to be the superior microbial culture, with ethanol as carbon source as compared to acetate. To enhance the rate of denitrification, acclimatization to nitrate (at 100, 200, 400, 800, and 1,600 mg N-NO3/L) was carried out in sequencing batch reactors over a 3-month period under anoxic condition, and comparisons were made between the performances of acclimated and non-acclimated sludges at each stage. It was found that acclimatization up to the fourth stage enhanced the specific denitrification rate to a high value of 29.6 mg N-NO3/h/g mixed liquor suspended solids (MLSS), with no significant nitrite accumulation. Additionally, the effect of initial pH (6, 6.5, 7, and 7.5) and carbon-to-nitrogen (C/N) ratio (1, 1.5, 2, and 3) on the performance of this final acclimated sludge was assessed, where initial pH of 7 and C/N ratio of 1.5 resulted in the best performances considering both nitrate and nitrite removal.
Removal of aluminum from drinking water treatment sludge using vacuum electrokinetic technology.
Xu, Hang; Ding, Mingmei; Shen, Kunlun; Cui, Jianfeng; Chen, Wei
2017-04-01
A vacuum electrokinetic apparatus was operated at a municipal water supply plant in Wuxi, China to study the removal of aluminum from the plant's drinking water treatment sludge, high in trivalent aluminum content. The effect of several experimental variables (initial pH, potential gradient, and zone in the sludge tank) and the trivalent aluminum removal mechanism were analyzed. The speciation of trivalent aluminum mainly depends on the initial pH of drinking water treatment sludge, and more fractions of trivalent aluminum were migrated at pH 4 than at higher or lower pH. The application of high voltage can enhance the removal efficiency of aluminum. A three-dimensional electric field analysis explained the difference in the removal efficiency at different zones in the sludge tank. In view of energy consumption, when the initial pH was 4 and a potential gradient of 2 V cm -1 was applied, achieving a final aluminum concentration of 30 g kg -1 after 120 h. The specific energy consumption was 11.7 kWh kg -1 of Al removed. Copyright © 2017 Elsevier Ltd. All rights reserved.
El-Naggar, Hesham M
2010-01-01
Ground water is the only water resource for Siwa Oasis. It is obtained from natural freshwater wells and springs fed by the Nubian aquifer. Water samples collected from Siwa Oasis had relatively higher iron (Fe) and manganese (Mn) than the permissible limits specified in WHO Guidelines and Egyptian Standards for drinking water quality. Aeration followed by sand filtration is the most commonly used method for the removal of iron from ground water. The study aimed at development of low-cost technology for the removal of iron and manganese from ground water in Siwa Oasis. The study was carried out on Laboratory-scale columns experiments sand filters with variable depths of 15, 30, 45, 60, 75, 90 cm and three graded types of sand were studied. The graded sand (E.S. =0.205 mm, U.C. =3.366, depth of sand = 60 cm and filtration rate = 1.44 m3/m2/hr) was the best type of filter media. Iron and manganese concentrations measured in ground water with aeration only, decreased with an average removal percentage of 16%, 13% respectively. Iron and manganese concentrations after filtration with aeration came down to 0.1123, 0.05 mg/L respectively in all cases from an initial concentration of 1.14, 0.34 mg/L respectively. Advantages of such treatment unit included simplicity, low cost design, and no need for chemical addition. In addition, the only maintenance required was periodic washing of the sand filter or replacement of the sand in order to maintain reasonable flow rate through the system.
2016-01-01
Mangrove crabs influence ecosystem processes through bioturbation and/or litter feeding. In Brazilian mangroves, the abundant and commercially important crab Ucides cordatus is the main faunal modifier of microtopography establishing up to 2 m deep burrows. They process more than 70% of the leaf litter and propagule production, thus promoting microbial degradation of detritus and benefiting microbe-feeding fiddler crabs. The accelerated nutrient turn-over and increased sediment oxygenation mediated by U. cordatus may enhance mangrove tree growth. Such positive feed-back loop was tested in North Brazil through a one year crab removal experiment simulating increased harvesting rates in a mature Rhizophora mangle forest. Investigated response parameters were sediment salinity, organic matter content, CO2 efflux rates of the surface sediment, and reduction potential. We also determined stipule fall of the mangrove tree R. mangle as a proxy for tree growth. Three treatments were applied to twelve experimental plots (13 m × 13 m each): crab removal, disturbance control and control. Within one year, the number of U. cordatus burrows inside the four removal plots decreased on average to 52% of the initial number. Despite this distinct reduction in burrow density of this large bioturbator, none of the measured parameters differed between treatments. Instead, most parameters were clearly influenced by seasonal changes in precipitation. Hence, in the studied R. mangle forest, abiotic factors seem to be more important drivers of ecosystem processes than factors mediated by U. cordatus, at least within the studied timespan of one year. PMID:27907093
Pülmanns, Nathalie; Mehlig, Ulf; Nordhaus, Inga; Saint-Paul, Ulrich; Diele, Karen
2016-01-01
Mangrove crabs influence ecosystem processes through bioturbation and/or litter feeding. In Brazilian mangroves, the abundant and commercially important crab Ucides cordatus is the main faunal modifier of microtopography establishing up to 2 m deep burrows. They process more than 70% of the leaf litter and propagule production, thus promoting microbial degradation of detritus and benefiting microbe-feeding fiddler crabs. The accelerated nutrient turn-over and increased sediment oxygenation mediated by U. cordatus may enhance mangrove tree growth. Such positive feed-back loop was tested in North Brazil through a one year crab removal experiment simulating increased harvesting rates in a mature Rhizophora mangle forest. Investigated response parameters were sediment salinity, organic matter content, CO2 efflux rates of the surface sediment, and reduction potential. We also determined stipule fall of the mangrove tree R. mangle as a proxy for tree growth. Three treatments were applied to twelve experimental plots (13 m × 13 m each): crab removal, disturbance control and control. Within one year, the number of U. cordatus burrows inside the four removal plots decreased on average to 52% of the initial number. Despite this distinct reduction in burrow density of this large bioturbator, none of the measured parameters differed between treatments. Instead, most parameters were clearly influenced by seasonal changes in precipitation. Hence, in the studied R. mangle forest, abiotic factors seem to be more important drivers of ecosystem processes than factors mediated by U. cordatus, at least within the studied timespan of one year.
Mecoprop (MCPP) removal in full-scale rapid sand filters at a groundwater-based waterworks.
Hedegaard, Mathilde J; Arvin, Erik; Corfitzen, Charlotte B; Albrechtsen, Hans-Jørgen
2014-11-15
Contamination by the herbicide mecoprop (MCPP) was detected in groundwater abstraction wells at Kerteminde Waterworks in concentrations up to 0.08μg/L. MCPP was removed to below detection limit in a simple treatment line where anaerobic groundwater was aerated and subsequently filtered by primary and secondary rapid sand filters. Water quality parameters were measured throughout the waterworks, and they behaved as designed for. MCPP was removed in secondary rapid sand filters--removal was the greatest in the sand filters in the filter line with the highest contact time (63 min). In these secondary sand filters, MCPP concentration decreased from 0.037 μg/L to below the detection limit of 0.01 μg/L. MCPP was removed continuously at different filter depths (0.80 m). Additionally, biodegradation, mineralisation and adsorption were investigated in the laboratory in order to elucidate removal mechanisms in the full-scale system. Therefore, microcosms were set up with filter sand, water and (14)C-labelled MCPP at an initial concentration of 0.2 μg/L. After 24 h, 79-86% of the initial concentration of MCPP was removed. Sorption removed 11-15%, while the remaining part was removed by microbial processes, leading to a complete mineralisation of 13-18%. Microbial removal in the filter sand was similar at different depths of the rapid sand filter, while the amount of MCPP which adsorbed to the filter sand after 48 h decreased with depth from 21% of the initial MCPP in the top layer to 7% in the bottom layer. It was concluded that MCPP was removed in secondary rapid sand filters at Kerteminde Waterworks, to which both adsorption and microbial degradation contributed. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kurucz, Charles N.; Waite, Thomas D.; Otaño, Suzana E.; Cooper, William J.; Nickelsen, Michael G.
2002-11-01
The effectiveness of using high energy electron beam irradiation for the removal of toxic organic chemicals from water and wastewater has been demonstrated by commercial-scale experiments conducted at the Electron Beam Research Facility (EBRF) located in Miami, Florida and elsewhere. The EBRF treats various waste and water streams up to 450 l min -1 (120 gal min -1) with doses up to 8 kilogray (kGy). Many experiments have been conducted by injecting toxic organic compounds into various plant feed streams and measuring the concentrations of compound(s) before and after exposure to the electron beam at various doses. Extensive experimentation has also been performed by dissolving selected chemicals in 22,700 l (6000 gal) tank trucks of potable water to simulate contaminated groundwater, and pumping the resulting solutions through the electron beam. These large-scale experiments, although necessary to demonstrate the commercial viability of the process, require a great deal of time and effort. This paper compares the results of large-scale electron beam irradiations to those obtained from bench-scale irradiations using gamma rays generated by a 60Co source. Dose constants from exponential contaminant removal models are found to depend on the source of radiation and initial contaminant concentration. Possible reasons for observed differences such as a dose rate effect are discussed. Models for estimating electron beam dose constants from bench-scale gamma experiments are presented. Data used to compare the removal of organic compounds using gamma irradiation and electron beam irradiation are taken from the literature and a series of experiments designed to examine the effects of pH, the presence of turbidity, and initial concentration on the removal of various organic compounds (benzene, toluene, phenol, PCE, TCE and chloroform) from simulated groundwater.
Wang, Sheng-ye; Tang, Yan-kui; Li, Kun; Mo, Ya-yuan; Li, Hao-feng; Gu, Zhan-qi
2014-12-01
Magnetic biochar was prepared with eucalyptus leaf residue remained after essential oil being extracted. Batch experiments were conducted to examine the capacity of the magnetic biochar to remove Cr (VI) from electroplating wastewater and to be separated by an external magnetic field. The results show that the initial solution pH plays an important role on both sorption and separation. The removal rates of Cr (VI), total Cr, Cu (II), and Ni (II) were 97.11%, 97.63%, 100% and 100%, respectively. The turbidity of the sorption-treated solution was reduced to 21.8NTU from 4075NTU after 10min magnetic separation. The study also confirms that the magnetic biochar still retains the original magnetic separation performance after the sorption process. Copyright © 2014 Elsevier Ltd. All rights reserved.
Kinetics of chromate reduction during naphthalene degradation in a mixed culture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, H.; Sewell, G.W.; Pritchard, P.H.
A mixed culture of Bacillus sp. K1 and Sphingomonas paucimobilis EPA 505 was exposed to chromate and naphthalene. Batch experiments showed that chromate was reduced and naphthalene was degraded by the mixed culture. Chromate reduction occurred initially at a high rate followed by a decrease in rate until chromate reduction ceased. Chromate reduction decreased in the mixed culture when a lower ratio of S. paucimobilis EPA 505 to Bacillus sp. K1 was utilized. A kinetic model incorporating a term for the cell density ratio is proposed to describe chromate reduction in the mixed culture under both chromate limited and electronmore » donor limited conditions. The validity of the model, and its parameter values, was verified by experimental data generated under a variety of initial population compositions and a broad range of chromate concentrations. The consistent result of experimental data with model predictions implies that the model is useful for evaluating the interactions and the use of mixed culture for chromate removal.« less
Water decontamination containing nitrate using biosorption with Moringa oleifera in dynamic mode.
Paixão, Rebecca Manesco; Reck, Isabela Maria; Gomes, Raquel Guttierres; Bergamasco, Rosângela; Vieira, Marcelo Fernandes; Vieira, Angélica Marquetotti Salcedo
2018-05-20
This study was conducted to assess the feasibility of using Moringa oleifera Lam. (MO) seeds in the biosorption of nitrate present in aqueous solutions by means of batch and fixed-bed column biosorption processes. The batch assays showed that nitrate biosorption is enhanced under experimental conditions of pH 3 and a biosorbent mass of 0.05 g. For the experiments in dynamic mode, the results obtained from the statistical parameters showed that lesser pH, lesser feed flow rate, and higher initial concentration will result in an increase of the maximum capacity of the bed. These conditions were confirmed by experimental analysis. The best experimental conditions, according to the values for percentage removal (91.09%) and maximum capacity (7.69 mg g -1 ) of the bed, were those used in assay 1, which utilized pH 3, feed flow rate of 1 mL min -1 , and initial nitrate concentration of 100 mg L -1 .
Wang, Wenwen; Zhang, Hao; Zhang, Zhifeng; Luo, Mengying; Wang, Yuedan; Liu, Qiongzhen; Chen, Yuanli; Li, Mufang; Wang, Dong
2017-02-01
In this study, poly(vinyl alcohol-co-ethylene) (PVA-co-PE) nanofibrous membrane was activated by sodium hydroxide and cyanuric chloride, and then the activated membranes were functionalized by 1,3-propanediamine, hexamethylenediamine and diethylenetriamine to be affinity membranes for bilirubin removal, respectively. The chemical structures and morphologies of membranes were investigated by SEM, FTIR and XPS. And the adsorption ability of different amine-functionalized nanofibrous membranes for bilirubin was characterized. Furthermore, the effects of temperature, initial concentration of bilirubin, NaCl concentration and BSA concentration on the adsorption capacity for bilirubin of diethylenetriamine-functionalized nanofibrous membrane were studied. Results indicated that the adsorption capacity for bilirubin of diethylenetriamine-functionalized nanofibrous membrane could reach 85mg/g membrane when the initial bilirubin concentration was 200mg/L while the adsorption capacity could be increased to 110mg/g membrane if the initial bilirubin concentration was more than 400mg/L. The dynamic adsorption of diethylenetriamine-functionalized nanofibrous membrane showed that the ligands of amine groups on the membrane surface could be used as far as possible by recirculating the plasma with certain flow rates. Therefore, the diethylenetriamine-functionalized PVA-co-PE nanofibrous membrane possessed high adsorption capacity for bilirubin and it can be candidate as affinity membrane for bilirubin removal. Copyright © 2016. Published by Elsevier B.V.