Sample records for initial testing shows

  1. Anthrax

    DTIC Science & Technology

    2009-01-01

    antimicrobials listed below) Initial therapye (intravenous dosing) Oral dosing Initial therapy (intravenous) IV treatment initially Switch to oral...high index of suspicion for anthrax, initiation of therapy should not be delayed for results of these confirmatory tests. 1. MICROBIOLOGICAL TESTS...Sputum specimens from inhalational anthrax patients should be plated on chocolate agar, SBA, and MAC. Cultures will show isolated B. anthracis

  2. A Study on the Mechanical Properties and Impact-Induced Initiation Characteristics of Brittle PTFE/Al/W Reactive Materials.

    PubMed

    Ge, Chao; Maimaitituersun, Wubuliaisan; Dong, Yongxiang; Tian, Chao

    2017-04-26

    Polytetrafluoroethylene/aluminum/tungsten (PTFE/Al/W) reactive materials of three different component mass ratios (73.5/26.5/0, 68.8/24.2/7 and 63.6/22.4/14) were studied in this research. Different from the PTFE/Al/W composites published elsewhere, the materials in our research were fabricated under a much lower sintering temperature and for a much shorter duration to achieve a brittle property, which aims to provide more sufficient energy release upon impact. Quasi-static compression tests, dynamic compression tests at room and elevated temperatures, and drop weight tests were conducted to evaluate the mechanical and impact-induced initiation characteristics of the materials. The materials before and after compression tests were observed by a scanning electron microscope to relate the mesoscale structural characteristics to their macro properties. All the three types of materials fail at very low strains during both quasi-static and dynamic compression. The stress-strain curves for quasi-static tests show obvious deviations while that for the dynamic tests consist of only linear-elastic and failure stages typically. The materials were also found to exhibit thermal softening at elevated temperatures and were strain-rate sensitive during dynamic tests, which were compared using dynamic increase factors (DIFs). Drop-weight test results show that the impact-initiation sensitivity increases with the increase of W content due to the brittle mechanical property. The high-speed video sequences and recovered sample residues of the drop-weight tests show that the reaction is initiated at two opposite positions near the edges of the samples, where the shear force concentrates the most intensively, indicating a shear-induced initiation mechanism.

  3. A Study on the Mechanical Properties and Impact-Induced Initiation Characteristics of Brittle PTFE/Al/W Reactive Materials

    PubMed Central

    Ge, Chao; Maimaitituersun, Wubuliaisan; Dong, Yongxiang; Tian, Chao

    2017-01-01

    Polytetrafluoroethylene/aluminum/tungsten (PTFE/Al/W) reactive materials of three different component mass ratios (73.5/26.5/0, 68.8/24.2/7 and 63.6/22.4/14) were studied in this research. Different from the PTFE/Al/W composites published elsewhere, the materials in our research were fabricated under a much lower sintering temperature and for a much shorter duration to achieve a brittle property, which aims to provide more sufficient energy release upon impact. Quasi-static compression tests, dynamic compression tests at room and elevated temperatures, and drop weight tests were conducted to evaluate the mechanical and impact-induced initiation characteristics of the materials. The materials before and after compression tests were observed by a scanning electron microscope to relate the mesoscale structural characteristics to their macro properties. All the three types of materials fail at very low strains during both quasi-static and dynamic compression. The stress-strain curves for quasi-static tests show obvious deviations while that for the dynamic tests consist of only linear-elastic and failure stages typically. The materials were also found to exhibit thermal softening at elevated temperatures and were strain-rate sensitive during dynamic tests, which were compared using dynamic increase factors (DIFs). Drop-weight test results show that the impact-initiation sensitivity increases with the increase of W content due to the brittle mechanical property. The high-speed video sequences and recovered sample residues of the drop-weight tests show that the reaction is initiated at two opposite positions near the edges of the samples, where the shear force concentrates the most intensively, indicating a shear-induced initiation mechanism. PMID:28772812

  4. Effects of Polarization on Mechanical Properties of Lead Zirconate Titanate Ceramics Evaluated by Modified Small Punch Tests

    NASA Astrophysics Data System (ADS)

    Deng, Qihuang; Fan, Yuchi; Wang, Lianjun; Xiong, Zhi; Wang, Hongzhi; Li, Yaogang; Zhang, Qinghong; Kawasaki, Akira; Jiang, Wan

    2012-01-01

    Pb(Zr,Ti)O3 (PZT) ceramics were prepared by the conventional mixed oxide method, and the strength of the resultant PZT ceramics was evaluated using modified small punch (MSP) tests. Load-displacement curve test results showed that the crack-initiation and fracture strengths of PZT ceramics decreased after polarization. The effect of the polarization accelerated the fatigue properties of PZT ceramics. Scanning electron microscopy (SEM) results showed that microcracks were formed before the maximum load in the MSP test, and the first load drop corresponded to crack initiation.

  5. Preliminary Results of Solid Gas Generator Micropropulsion

    NASA Technical Reports Server (NTRS)

    deGroot, Wilhelmus A.; Reed, Brian D.; Brenizer, Marshall

    1999-01-01

    A decomposing solid thruster concept, which creates a more benign thermal and chemical environment than solid propellant combustion, while maintaining, performance similar to solid combustion, is described. A Micro-Electro-Mechanical (MEMS) thruster concept with diode laser and fiber-optic initiation is proposed, and thruster components fabricated with MEMS technology are presented. A high nitrogen content solid gas generator compound is evaluated and tested in a conventional axisymmetric thrust chamber with nozzle throat area ratio of 100. Results show incomplete decomposition of this compound in both low pressure (1 kPa) and high pressure (1 MPa) environments, with decomposition of up to 80% of the original mass. Chamber pressures of 1.1 MPa were obtained, with maximum calculated thrust of approximately 2.7 N. Resistively heated wires and resistively heated walls were used to initiate decomposition. Initiation tests using available lasers were unsuccessful, but infrared spectra of the compound show that the laser initiation tests used inappropriate wavelengths for optimal propellant absorption. Optimal wavelengths for laser ignition were identified. Data presented are from tests currently in progress. Alternative solid gas generator compounds are being evaluated for future tests.

  6. Dynamics of an Overdriven Nitromethane Initiation System

    NASA Astrophysics Data System (ADS)

    Hároz, E. H.; Rae, P. J.; Armstrong, C. L.; Baca, E. V.; Campbell, C.; Gunderson, J. A.; Holmes, M.; Lopez-Pulliam, I.; Vaughan, L. D.; Dickson, P. M.

    2017-06-01

    For upcoming large-scale HE experiments, an initiation system is needed to ensure uniform and simultaneous burn. To that end, we developed an initiation system based on nitromethane. Initial, small-scale tests characterized the response of the nitromethane in the proposed cylindrical initiator geometry, indicating robust detonation under a variety of conditions such as a plane wave lenses & cylinders of PBX 9501 into a flyer plate or direct-drive. Detonation velocity, as measured by piezoelectric pin time-of-arrival measurements along the length and at bottom of vessel, shows an overdriven response. All cases show a detonation velocity faster than the literature value of 7.3 km s-1 for nitromethane, with the fastest velocity occurring for the 8-detonator, 8'' cylinder case with a velocity = 7.7 km s-1. Streak camera imaging characterized the curvature of the shock front as it arrived at the bottom of the vessel via spark gap. A final test of the initiator system looked at the expansion of the initiator vessel walls via PDV, showing velocities up to 3.5 km s-1. Finally, our initiator was placed inside a secondary vessel containing 1000 lbs of nitromethane. High-speed photography & pin data indicate complete symmetrical burn of the secondary nitromethane.

  7. Eye-movement evidence of the time-course of attentional bias for threatening pictures in test-anxious students.

    PubMed

    Dong, Yunying; De Beuckelaer, Alain; Yu, Liang; Zhou, Renlai

    2017-06-01

    Protocols for measuring attentional bias to threat in test-anxiety, a special form of trait-anxiety, are rarely found in the literature. In our eye-tracking study, we introduced a new protocol, and studied the time-course of attention to test-related pictures with varying threat levels in 22 high test-anxious (HTA) and 22 low test-anxious (LTA) subjects. To determine whether attentional bias to test-related pictures is due to test-anxiety and not to state-anxiety, we also included a third group of 22 subjects with high state-anxiety but low test-anxiety (HSA). The subjects completed a free viewing task (FVT) in which high threat-neutral (HT-N) and low threat-neutral (LT-N) picture pairs were presented for 3 s. The results demonstrated that: (1) HTA subjects showed initial orienting to LT pictures, early attentional engagement with HT pictures later on and avoidance of HT pictures at the very end; (2) LTA subjects showed initial orienting to HT pictures and maintenance of attention on them later on; while (3) HSA subjects showed an initial orientation towards LT pictures and maintenance of attention on LT and HT pictures later on. These results suggest that, (high) test-anxiety is also prone to attentional bias towards test-related threat stimuli. Implications for future research are discussed.

  8. Improving Beta Test Evaluation Response Rates: A Meta-Evaluation

    ERIC Educational Resources Information Center

    Russ-Eft, Darlene; Preskill, Hallie

    2005-01-01

    This study presents a meta-evaluation of a beta-test of a customer service training program. The initial evaluation showed a low response rate. Therefore, the meta-evaluation focused on issues related to the conduct of the initial evaluation and reasons for nonresponse. The meta-evaluation identified solutions to the nonresponse problem as related…

  9. Retrieval enhances eyewitness suggestibility to misinformation in free and cued recall.

    PubMed

    Wilford, Miko M; Chan, Jason C K; Tuhn, Sam J

    2014-03-01

    Immediately recalling a witnessed event can increase people's susceptibility to later postevent misinformation. But this retrieval-enhanced suggestibility (RES) effect has been shown only when the initial recall test included specific questions that reappeared on the final test. Moreover, it is unclear whether this phenomenon is affected by the centrality of event details. These limitations make it difficult to generalize RES to criminal investigations, which often begin with free recall prior to more specific queries from legal officials and attorneys. In 3 experiments, we examined the influence of test formats (free recall vs. cued recall) and centrality of event details (central vs. peripheral) on RES. In Experiment 1, both the initial and final tests were cued recall. In Experiment 2, the initial test was free recall and the final test was cued recall. In Experiment 3, both the initial and final tests were free recall. Initial testing increased misinformation reporting on the final test for peripheral details in all experiments, but the effect was significant for central details only after aggregating the data from all 3 experiments. These results show that initial free recall can produce RES, and more broadly, that free recall can potentiate subsequent learning of complex prose materials. © 2013 American Psychological Association

  10. Pilot-in-the-Loop CFD Method Development

    DTIC Science & Technology

    2017-04-20

    the methods on the NAVAIR Manned Flight Simulator. Activities this period During this report period, we implemented the CRAFT CFD code on the...Penn State VLRCROE Flight simulator and performed the first Pilot-in-the-Loop PILCFD tests at Penn State using the COCOA5 clusters. The initial tests...integration of the flight simulator and Penn State computing infrastructure. Initial tests showed slower performance than real-time (3x slower than real

  11. A Simple Answer to a Simple Question on Changing Answers

    ERIC Educational Resources Information Center

    Bridgeman, Brent

    2012-01-01

    In an article in the Winter 2011 issue of the "Journal of Educational Measurement", van der Linden, Jeon, and Ferrara suggested that "test takers should trust their initial instincts and retain their initial responses when they have the opportunity to review test items." They presented a complex IRT model that appeared to show that students would…

  12. Particle Size Effects on CL-20 Initiation and Detonation

    NASA Astrophysics Data System (ADS)

    Valancius, Cole; Bainbridge, Joe; Love, Cody; Richardson, Duane

    2017-06-01

    Particle size or specific surface area effects on explosives has been of interest to the explosives community for both application and modeling of initiation and detonation. Different particles sizes of CL-20 were used in detonator experiments to determine the effects of particle size on initiation, run-up to steady state detonation, and steady state detonation. Historical tests have demonstrated a direct relationship between particle size and initiation. However, historical tests inadvertently employed density gradients, making it difficult to discern the effects of particle size from the effects of density. Density gradients were removed from these tests using a larger diameter, shorter charge column, allowing for similar loading across different particle sizes. Without the density gradient, the effects of particle size on initiation and detonation are easier to determine. The results of which contrast with historical results, showing particle size does not directly affect initiation threshold.

  13. NASA Standard Initiator Susceptibility to UHF and S-Band Radio Frequency Power and Lightning Strikes

    NASA Technical Reports Server (NTRS)

    Burnham, Karen; Scully, Robert; Norgard, John

    2013-01-01

    The NASA Standard Initiator (NSI) is an important piece of pyrotechnic equipment used in many space applications. This presentation will outline the results of a series of tests done at UHF and S-Band frequencies to determine NSI susceptibility to Radio Frequency (RF) power. The results show significant susceptibility to pulsed RF power in the S-Band region. Additional testing with lightning pulses injected into the firing line harness, modelling the indirect effects of a lightning strike to a spacecraft, showed no vulnerability

  14. NASA Standard Initiator Susceptibility to UHF and S-Band Radio Frequency Power and Lightning Strikes

    NASA Technical Reports Server (NTRS)

    Burnham, Karen; Scully, Robert C.; Norgard, John D.

    2013-01-01

    The NASA Standard Initiator (NSI) is an important piece of pyrotechnic equipment used in many space applications. This paper outlines the results of a series of tests done at UHF and S-Band frequencies to determine NSI susceptibility to Radio Frequency (RF) power. The results show significant susceptibility to pulsed RF power in the S-Band region. Additional testing with lightning pulses injected into the firing line harness, modelling the indirect effects of a lightning strike to a spacecraft, showed no vulnerability.

  15. The views and experiences of nurses and midwives in the provision and management of provider-initiated HIV testing and counseling: a systematic review of qualitative evidence.

    PubMed

    Evans, Catrin; Nalubega, Sylivia; McLuskey, John; Darlington, Nicola; Croston, Michelle; Bath-Hextall, Fiona

    2016-01-15

    Global progress towards HIV prevention and care is contingent upon increasing the number of those aware of their status through HIV testing. Provider-initiated HIV testing and counseling is recommended globally as a strategy to enhance uptake of HIV testing and is primarily conducted by nurses and midwives. Research shows that provider-initiated HIV testing and counseling implementation is sub-optimal. The reasons for this are unclear. The review aimed to explore nurses' and midwives' views and experiences of the provision and management of provider-initiated HIV testing and counseling. All cadres of nurses and midwives were considered, including those who undertake routine HIV testing as part of a diverse role and those who are specifically trained as HIV counselors. Types of phenomenon of interest: The review sought to understand the views and experiences of the provision and management of provider-initiated HIV testing and counseling (including perceptions, opinions, beliefs, practices and strategies related to HIV testing and its implementation in practice). The review included only provider-initiated HIV testing and counseling. It excluded all other models of HIV testing. The review included all countries and all healthcare settings. Types of studies: This review considered all forms of qualitative study design and methodology. Qualitative elements of a mixed method study were included if they were presented separately within the publication. A three-step search strategy was utilized. Eight databases were searched for papers published from 1996 to October 2014, followed by hand searching of reference lists. Only studies published in the English language were considered. Methodological quality was assessed using the Qualitative Assessment and Review Instrument developed by the Joanna Briggs Institute. Qualitative findings were extracted using the Joanna Briggs Institute Qualitative Assessment and Review Instrument. Qualitative research findings were pooled using a pragmatic meta-aggregative approach and the Joanna Briggs Institute Qualitative Assessment and Review Instrument software. This review included 21 publications from 18 research studies, representing a wide range of countries and healthcare settings. There were 245 findings which were aggregated into 12 categories and five synthesized findings. 1. Nurses/midwives are supportive of provider-initiated HIV testing and counseling if it is perceived to enhance patient care and to align with perceived professional roles. 2. Nurses'/midwives' ability to perform provider-initiated HIV testing and counseling well requires an appropriate infrastructure and adequate human and material resources. 3. At the organizational level, nurses'/midwives' engagement with provider-initiated HIV testing and counseling is facilitated by an inclusive management structure, alongside the provision of ongoing training and clinical supervision. Provider-initiated HIV testing and counseling is hindered by difficulties in fitting it into existing workloads and routines. 4. Nurses/midwives perceive that good quality care in provider-initiated HIV testing and counseling involves finding a balance between public health needs and individual patient needs. Good care requires time and the ability to apply a patient centred approach. 5. The emotional work involved in provider-initiated HIV testing and counseling can be stressful. Nurses/Midwives may require support to deal with complex moral and ethical issues. This review shows that provider-initiated HIV testing and counseling is supported by nurses/midwives who strive to implement it according to principles of good care and a patient centered approach. Nurses/midwives face multiple operational, infra-structural, resource and ethical challenges in the implementation of provider-initiated HIV testing and counseling. The implementation process for provider-initiated HIV testing and counseling would benefit from using a quality improvement framework. Nurses/midwives undertaking provider-initiated HIV testing and counseling require management support, ongoing training and adequate infrastructure/resources. Additional guidance is required on legal/ethical issues in testing of children and in third party disclosure. Operational research is required to determine an optimal skill mix and optimal methods of integrating provider-initiated HIV testing and counseling into existing work routines. The Joanna Briggs Institute.

  16. Initial test results with a single-cylinder rhombic-drive Stirling engine. [to be applied to automobile engine design to conserve energy

    NASA Technical Reports Server (NTRS)

    Cairelli, J. E.; Thieme, L. G.; Walter, R. J.

    1978-01-01

    A 6 kW (8 hp), single-cylinder, rhombic-drive Stirling engine was restored to operating condition, and preliminary characterization tests run with hydrogen and helium as the working gases. Initial tests show the engine brake specific fuel consumption (BSFC) with hydrogen working gas to be within the range of BSFC observed by the Army at Fort Belvoir, Virginia, in 1966. The minimum system specific fuel consumption (SFC) observed during the initial tests with hydrogen was 669 g/kW hr (1.1 lb/hpx hr), compared with 620 g/kWx hr (1.02 lb/hpx hr) for the Army tests. However, the engine output power for a given mean compression-space pressure was lower than for the Army tests. The observed output power at a working-space pressure of 5 MPa (725 psig) was 3.27 kW (4.39 hp) for the initial tests and 3.80 kW (5.09 hp) for the Army tests. As expected, the engine power with helium was substantially lower than with hydrogen.

  17. Partial hypopituitarism and Langerhans cell histiocytosis

    PubMed Central

    Balaguruswamy, S; Chattington, P D

    2011-01-01

    A case of multisystem Langerhans cell histiocytosis with pituitary involvement nearly 20 years after initial presentation. A 48-year-old man had histiocytosis X 22 years ago initially involving the groin; subsequently his external auditory meatus, scalp, gum, mandibular bone, perineum and axilla were involved and treated. The pituitary gland was involved 4 years ago. A thyrotropin-releasing hormone test showed delayed response suggestive of hypothalamic disease. Prolactin levels were normal. A gonadotropin-releasing hormone test showed impaired testosterone and gonadotrophin response in keeping with pituitary disease. A glucagon stimulation test showed an impaired growth hormone response but a normal cortisol increase. MRI pituitary showed an empty sella. There was no evidence of diabetes insipidus. Bone mineral densitometry was normal. He has partial hypopituitarism needing thyroxine and testosterone replacement. He also developed type 2 diabetes mellitus 9 years ago. He is closely monitored for any development of diabetes insipidus and the need for growth hormone supplementation. PMID:22715201

  18. In the DNA Exoneration Cases, Eyewitness Memory Was Not the Problem: A Reply to Berkowitz and Frenda (2018) and Wade, Nash, and Lindsay (2018).

    PubMed

    Wixted, John T; Mickes, Laura; Fisher, Ronald P

    2018-05-01

    The available real-world evidence suggests that, on an initial test, eyewitness memory is often reliable. Ironically, even the DNA exoneration cases-which generally involved nonpristine testing conditions and which are usually construed as an indictment of eyewitness memory-show how reliable an initial test of eyewitness memory can be in the real world. We endorse the use of pristine testing procedures, but their absence does not automatically imply that eyewitness memory is unreliable.

  19. The development and initial validation of a sensitive bedside cognitive screening test.

    PubMed

    Faust, D; Fogel, B S

    1989-01-01

    Brief bedside cognitive examinations such as the Mini-Mental State Examination are designed to detect delirium and dementia but not more subtle or delineated cognitive deficits. Formal neuropsychological evaluation provides greater sensitivity and detects a wider range of cognitive deficits but is too lengthy for efficient use at the bedside or in epidemiological studies. The authors developed the High Sensitivity Cognitive Screen (HSCS), a 20-minute interview-based test, to identify patients who show disorder on formal neuropsychological evaluation. An initial study demonstrated satisfactory test-retest and interrater reliability. The HSCS was then administered to 60 psychiatric and neurological patients with suspected cognitive deficits but without gross impairment, who also completed formal neuropsychological testing. Results of both tests were independently classified as either normal, borderline, or abnormal. The HSCS correctly classified 93% of patients across the normal-abnormal dichotomy and showed promise for characterizing the extent and severity of cognitive dysfunction.

  20. Tension and Bending Testing of an Integral T-Cap for Stitched Composite Airframe Joints

    NASA Technical Reports Server (NTRS)

    Lovejoy, Andrew E.; Leone, Frank A., Jr.

    2016-01-01

    The Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) is a structural concept that was developed by The Boeing Company to address the complex structural design aspects associated with a pressurized hybrid wing body aircraft configuration. An important design feature required for assembly is the integrally stitched T-cap, which provides connectivity of the corner (orthogonal) joint between adjacent panels. A series of tests were conducted on T-cap test articles, with and without a rod stiffener penetrating the T-cap web, under tension (pull-off) and bending loads. Three designs were tested, including the baseline design used in large-scale test articles. The baseline had only the manufacturing stitch row adjacent to the fillet at the base of the T-cap web. Two new designs added stitching rows to the T-cap web at either 0.5- or 1.0-inch spacing along the height of the web. Testing was conducted at NASA Langley Research Center to determine the behavior of the T-cap region resulting from the applied loading. Results show that stitching arrests the initial delamination failures so that the maximum strength capability exceeds the load at which the initial delaminations develop. However, it was seen that the added web stitching had very little effect on the initial delamination failure load, but actually decreased the initial delamination failure load for tension loading of test articles without a stiffener passing through the web. Additionally, the added web stitching only increased the maximum load capability by between 1% and 12.5%. The presence of the stiffener, however, did increase the initial and maximum loads for both tension and bending loading as compared to the stringerless baseline design. Based on the results of the few samples tested, the additional stitching in the T-cap web showed little advantage over the baseline design in terms of structural failure at the T-cap web/skin junction for the current test articles.

  1. Attitude algorithm and initial alignment method for SINS applied in short-range aircraft

    NASA Astrophysics Data System (ADS)

    Zhang, Rong-Hui; He, Zhao-Cheng; You, Feng; Chen, Bo

    2017-07-01

    This paper presents an attitude solution algorithm based on the Micro-Electro-Mechanical System and quaternion method. We completed the numerical calculation and engineering practice by adopting fourth-order Runge-Kutta algorithm in the digital signal processor. The state space mathematical model of initial alignment in static base was established, and the initial alignment method based on Kalman filter was proposed. Based on the hardware in the loop simulation platform, the short-range flight simulation test and the actual flight test were carried out. The results show that the error of pitch, yaw and roll angle is fast convergent, and the fitting rate between flight simulation and flight test is more than 85%.

  2. T-Cap Pull-Off and Bending Behavior for Stitched Structure

    NASA Technical Reports Server (NTRS)

    Lovejoy, Andrew E.; Leone, Frank A., Jr.

    2016-01-01

    The Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) is a structural concept that was developed by The Boeing Company to address the complex structural design aspects associated with a pressurized hybrid wing body aircraft configuration. An important design feature required for assembly is the integrally stitched T-cap, which provides connectivity of the corner (orthogonal) joint between adjacent panels. A series of tests were conducted on T-cap test articles, with and without a rod stiffener penetrating the T-cap web, under tension (pull-off) and bending loads. Three designs were tested, including the baseline design used in largescale test articles. The baseline had only the manufacturing stitch row adjacent to the fillet at the base of the T-cap web. Two new designs added stitching rows to the T-cap web at either 0.5- or 1.0-inch spacing along the height of the web. Testing was conducted at NASA Langley Research Center to determine the behavior of the T-cap region resulting from the applied loading. Results show that stitching arrests the initial delamination failures so that the maximum strength capability exceeds the load at which the initial delaminations develop. However, it was seen that the added web stitching had very little effect on the initial delamination failure load, but actually decreased the initial delamination failure load for tension loading of test articles without a stiffener passing through the web. Additionally, the added web stitching only increased the maximum load capability by between 1% and 12.5%. The presence of the stiffener, however, did increase the initial and maximum loads for both tension and bending loading as compared to the stringerless baseline design. Based on the results of the few samples tested, the additional stitching in the T-cap web showed little advantage over the baseline design in terms of structural failure at the T-cap web/skin junction for the current test articles.

  3. Microstructural studies on failure mechanisms in thermo-mechanical fatigue of repaired DS R80 and IN 738 Superalloys

    NASA Astrophysics Data System (ADS)

    Abrokwah, Emmanuel Otchere

    Directionally solidified Rene 80 (DS R80) and polycrystalline Inconel 738(IN 738) Superalloys were tested in thermo-mechanical fatigue (TMF) over the temperature range of 500-900°C and plastic strain range from 0.1 to 0.8% using a DSI Gleeble thermal simulator. Thermo-mechanical testing was carried out on the parent material (baseline) in the conventional solution treated and aged condition (STA), as well as gas tungsten arc welded (GTAW) with an IN-738 filler, followed by solution treatment and ageing. Comparison of the baseline alloy microstructure with that of the welded and heat treated alloy showed that varying crack initiation mechanisms, notably oxidation by stress assisted grain boundary oxidation, grain boundary MC carbides fatigue crack initiation, fatigue crack initiation from sample surfaces, crack initiation from weld defects and creep deformation were operating, leading to different “weakest link” and failure initiation points. The observations from this study show that the repaired samples had extra crack initiation sites not present in the baseline, which accounted for their occasional poor fatigue life. These defects include lack of fusion between the weld and the base metal, fusion zone cracking, and heat affected zone microfissures.

  4. Flower choice by naïve young crab spiders and the effect of subsequent experience.

    PubMed

    Morse

    2000-05-01

    Initial responses of naïve individuals to critical environmental stimuli provide important information about the innate contribution to behaviour, and subsequent responses to the same stimuli may show the role of experience in mediating those initial responses. To test the role of these factors, I measured initial patch choices and giving-up responses of just-emerged, naïve, second-instar crab spiders, Misumena vatia, on several hunting sites they encountered after leaving their natal nests. In follow-up tests I measured the effects of these experiences on subsequent patch choice decisions. The choice of hunting sites is a vital decision at all stages of the life cycle for sit-and-wait predators such as Misumena. In their initial tests these spiderlings remained more frequently on goldenrod (Solidago spp.) flowers than on green or yellow goldenrod buds, a preference they retained through tests run on 5 consecutive days. Individuals on green and yellow buds shifted sites more quickly and frequently than those from flowers, and made most of these moves to flowers, which attracted many more prey than did buds. These differences were not affected by age, energetic condition, or loss of information over the period of the experiment. Once spiderlings moved from buds, they showed a high, increasing tendency to move from buds in subsequent runs, those from flowers showed a consistently low tendency. These results suggest that spiderlings retain their innate behavioural patterns through the second instar, but that experience also plays a modest role in patch choice at this stage. Copyright 2000 The Association for the Study of Animal Behaviour.

  5. Distant stereoacuity in children with anisometropic amblyopia.

    PubMed

    Chung, Yeon Woong; Park, Shin Hae; Shin, Sun Young

    2017-09-01

    To characterize changes in distant stereoacuity using Frisby-Davis Distance test (FD2) and Distant Randot test (DR) during treatment for anisometropic amblyopia, to determine factors that influence posttreatment stereoacuity and to compare the two distant stereotests. Fifty-eight anisometropic amblyopic patients with an interocular difference of ≥1.00 diopter who achieved the visual acuity 20/20 following amblyopia treatment were retrospectively included. Stereoacuity using FD2 and DR for distant and Titmus test for near measurement were assessed and compared at the initial, intermediate, and final visit. Multivariate regression models were used to identify factors associated with initial and final stereoacuity. The two distant stereotests revealed a significant improvement in distant stereoacuity after successful amblyopia treatment. Distant stereoacuity using FD2 showed the greatest improvement during the follow up period. The number of nil scores was higher in DR than FD2 at each period. In multivariate analysis, better final stereoacuity was associated with better initial amblyopic eye acuity in both distant stereotests, but not in the Titmus test. Comparing the two distant stereotests, final stereoacuity using FD2 was associated with initial stereoacuity and was moderately related with the Titmus test at each period, but final stereoacuity using DR was not. Distant stereoacuity measured with both FD2 and DR showed significant improvement when the visual acuity of the amblyopic eye achieved 20/20. Changes in distant stereoacuity by FD2 and DR during the amblyopia treatment were somewhat different.

  6. Flexural testing on carbon fibre laminates taking into account their different behaviour under tension and compression

    NASA Astrophysics Data System (ADS)

    Serna Moreno, M. C.; Romero Gutierrez, A.; Martínez Vicente, J. L.

    2016-07-01

    An analytical model has been derived for describing the results of three-point-bending tests in materials with different behaviour under tension and compression. The shift of the neutral plane and the damage initiation mode and its location have been defined. The validity of the equations has been reviewed by testing carbon fibre-reinforced polymers (CFRP), typically employed in different weight-critical applications. Both unidirectional and cross-ply laminates have been studied. The initial failure mode produced depends directly on the beam span- thickness relation. Therefore, specimens with different thicknesses have been analysed for examining the damage initiation due to either the bending moment or the out-of-plane shear load. The experimental description of the damage initiation and evolution has been shown by means of optical microscopy. The good agreement between the analytical estimations and the experimental results shows the validity of the analytical model exposed.

  7. Experiments of thermomechanical fatigue of SMAs

    NASA Astrophysics Data System (ADS)

    Lagoudas, Dimitris C.; Miller, David A.

    1999-07-01

    As SMA wires are gaining in popularity for use as actuators, one constitutive parameter that remain unknown is the thermomechanical fatigue life. Even though the effect of thermal cycles on the transformation characteristics of SMAs has been studied, these teste have not been extended to high number of cycles. In this study, a novel test frame developed to study the thermomechanical fatigue life of SMAs is described. Additionally, a testing protocol is discussed necessary to fully establish the fatigue characteristics of SMAs under various conditions. Initial results of the initial test show a substantial increase in the number of cycles to failure as the applied stress level reduces to approximately 100 MPa.

  8. Electrochemical Testing of Ni-Cr-Mo-Gd Alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    T. E. Lister; R. E. Mizia; H. Tian

    2005-10-01

    The waste package site recommendation design specified a boron-containing stainless steel, Neutronit 976/978, for fabrication of the internal baskets that will be used as a corrosion-resistant neutron-absorbing material. Recent corrosion test results gave higher-than-expected corrosion rates for this material. The material callout for these components has been changed to a Ni-Cr-Mo-Gd alloy (ASTM-B 932-04, UNS N06464) that is being developed at the Idaho National Laboratory. This report discusses the results of initial corrosion testing of this material in simulated in-package environments that could contact the fuel baskets after breach of the waste package outer barrier. The corrosion test matrix wasmore » executed using the potentiodynamic and potentiostatic electrochemical test techniques. The alloy performance shows low rates of general corrosion after initial removal of a gadolinium-rich second phase that intersects the surface. The high halide-containing test solutions exhibited greater tendencies toward initiation of crevice corrosion.« less

  9. Hypothesis Testing in Task-Based Interaction

    ERIC Educational Resources Information Center

    Choi, Yujeong; Kilpatrick, Cynthia

    2014-01-01

    Whereas studies show that comprehensible output facilitates L2 learning, hypothesis testing has received little attention in Second Language Acquisition (SLA). Following Shehadeh (2003), we focus on hypothesis testing episodes (HTEs) in which learners initiate repair of their own speech in interaction. In the context of a one-way information gap…

  10. Performance of RASS vortex detection/measurement system

    DOT National Transportation Integrated Search

    1999-06-01

    Preliminary tests conducted by WLR Research in the Fall of 1993 showed considerable promise that a Radio Acoustic Sounding System (RASS) was capable of detecting and tracking wake vortices located in the approach glide slope. Initial testing of the R...

  11. A Seven-Year Follow-Up of Intelligence Test Scores of Foster Grandparents

    ERIC Educational Resources Information Center

    Troll, Lillian E.; And Others

    1976-01-01

    After seven years, a group (N=32) of originally nonemployed poverty-level older people (over 60) now employed as foster grandparents were retested with the WAIS. Three subtest scores showed stability and Digit Span showed a statistically significant drop. Neither age nor initial level of health or WAIS scores was related to test-score changes over…

  12. The role of retrieval mode and retrieval orientation in retrieval practice: insights from comparing recognition memory testing formats and restudying.

    PubMed

    Gao, Chuanji; Rosburg, Timm; Hou, Mingzhu; Li, Bingbing; Xiao, Xin; Guo, Chunyan

    2016-12-01

    The effectiveness of retrieval practice for aiding long-term memory, referred to as the testing effect, has been widely demonstrated. However, the specific neurocognitive mechanisms underlying this phenomenon remain unclear. In the present study, we sought to explore the role of pre-retrieval processes at initial testing on later recognition performance by using event-related potentials (ERPs). Subjects studied two lists of words (Chinese characters) and then performed a recognition task or a source memory task, or restudied the word lists. At the end of the experiment, subjects received a final recognition test based on the remember-know paradigm. Behaviorally, initial testing (active retrieval) enhanced memory retention relative to restudying (passive retrieval). The retrieval mode at initial testing was indexed by more positive-going ERPs for unstudied items in the active-retrieval tasks than in passive retrieval from 300 to 900 ms. Follow-up analyses showed that the magnitude of the early ERP retrieval mode effect (300-500 ms) was predictive of the behavioral testing effect later on. In addition, the ERPs for correctly rejected new items during initial testing differed between the two active-retrieval tasks from 500 to 900 ms, and this ERP retrieval orientation effect predicted differential behavioral testing gains between the two active-retrieval conditions. Our findings confirm that initial testing promotes later retrieval relative to restudying, and they further suggest that adopting pre-retrieval processing in the forms of retrieval mode and retrieval orientation might contribute to these memory enhancements.

  13. Initial testing of a variable-stroke Stirling engine

    NASA Technical Reports Server (NTRS)

    Thieme, L. G.

    1985-01-01

    In support of the U.S. Department of Energy's Stirling Engine Highway Vehicle Systems Program, NASA Lewis Research Center is evaluating variable-stroke control for Stirling engines. The engine being tested is the Advenco Stirling engine; this engine was manufactured by Philips Research Laboratories of the Netherlands and uses a variable-angle swash-plate drive to achieve variable stroke operation. The engine is described, initial steady-state test data taken at Lewis are presented, a major drive system failure and subsequent modifications are described. Computer simulation results are presented to show potential part-load efficiency gains with variable-stroke control.

  14. Normal sensory and range of motion (ROM) responses during Thoracic Slump Test (ST) in asymptomatic subjects.

    PubMed

    Joshi, Ketaki C; Eapen, Charu; Kumar, Senthil P

    2013-02-01

    The purpose of the study was to determine the normal sensory and range of motion (ROM) responses during the movement components of Thoracic Slump Test (Thoracic ST) in asymptomatic subjects. Sixty asymptomatic subjects were included in the study. Thoracic ST was performed in two sequences, proximal initiation, which was proximal to distal and distal initiation, which was distal to proximal. Subjects were randomized into four groups depending on the order of sequences and sides. Outcome measures of sensory responses (intensity, type, and location) and ROM responses were recorded after each sequence. Friedman's test was done to compare between sensory responses of the subjects. Between-component comparison for prevalence of sensory responses within each sequence was done using Kruskal-Wallis test and Wilcoxonsigned ranks test was used for between-component comparisons of intensity of symptoms within each sequence of testing. Independent t test was used to assess the ROM responses. Results show the prevalence of sensory responses, its nature, area and intensity. These sensory and ROM responses may be considered as normal response of Thoracic ST. The intensity of the symptoms of proximal initiation sequence (1.09±1.35 cm) was significant (P<0.05) when compared to distal initiation sequence (0.08±1.26 cm). The change in the ROM was significant (P<0.05) for distal initiation (7.55±4.51 degrees) when compared to proximal initiation (4.96±3.76 degrees). These normal responses may be used as a reference when using the Thoracic ST as an assessment technique.

  15. Normal sensory and range of motion (ROM) responses during Thoracic Slump Test (ST) in asymptomatic subjects

    PubMed Central

    Joshi, Ketaki C; Eapen, Charu; Kumar, Senthil P

    2013-01-01

    The purpose of the study was to determine the normal sensory and range of motion (ROM) responses during the movement components of Thoracic Slump Test (Thoracic ST) in asymptomatic subjects. Sixty asymptomatic subjects were included in the study. Thoracic ST was performed in two sequences, proximal initiation, which was proximal to distal and distal initiation, which was distal to proximal. Subjects were randomized into four groups depending on the order of sequences and sides. Outcome measures of sensory responses (intensity, type, and location) and ROM responses were recorded after each sequence. Friedman’s test was done to compare between sensory responses of the subjects. Between-component comparison for prevalence of sensory responses within each sequence was done using Kruskal–Wallis test and Wilcoxonsigned ranks test was used for between-component comparisons of intensity of symptoms within each sequence of testing. Independent t test was used to assess the ROM responses. Results show the prevalence of sensory responses, its nature, area and intensity. These sensory and ROM responses may be considered as normal response of Thoracic ST. The intensity of the symptoms of proximal initiation sequence (1.09±1.35 cm) was significant (P<0.05) when compared to distal initiation sequence (0.08±1.26 cm). The change in the ROM was significant (P<0.05) for distal initiation (7.55±4.51 degrees) when compared to proximal initiation (4.96±3.76 degrees). These normal responses may be used as a reference when using the Thoracic ST as an assessment technique. PMID:24421610

  16. Microstructural Effects on SCC Initiation PWR Primary Water Cold-Worked Alloy 600

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhai, Ziqing; Toloczko, Mychailo B.; Bruemmer, Stephen M.

    SCC initiation behavior of one mill annealed alloy 600 plate heat was investigated in simulated PWR primary water under constant load at yield stress with in-situ direct current potential drop (DCPD) monitoring for crack initiation. Twelve specimens were tested at similar cold work levels among which three showed much shorter SCC initiation times (<400 hrs) than the others (>1200 hrs). Post-test examinations revealed that these three specimens all feature an inhomogeneous microstructure where the primary crack always nucleated along the boundary of large elongated grains protruding normally into the gauge. In contrast, such microstructure was either not observed or didmore » not extend deep enough into the gauge in the other specimens exhibiting ~3-6X longer initiation times. In order to better understand the role of this microstructural inhomogeneity in SCC initiation, high-resolution microscopy was performed to compare carbide morphology and strain distribution between the long grains and normal grains, and their potential effects on SCC initiation are discussed in this paper.« less

  17. A 31-year-old man with bilateral blurry vision and floaters.

    PubMed

    Abazari, Azin; Kaplowitz, Kevin; Sibony, Patrick

    2015-01-01

    We report a case of bilateral multifocal retinochoroiditis and bilateral optic disc edema in a patient with cat-scratch disease from Bartonella henselae. The patient initially had negative serologic testing. Repeat testing showed a markedly increased IgG and IgM convalescent titer and the development of a branch retinal artery and vein occlusion. In patients for whom there is a high clinical suspicion of cat-scratch disease, a convalescent titer should be obtained 2-3 weeks following a negative initial result.

  18. Durability of Pt-Co Alloy Polymer Electrolyte Fuel Cell Cathode Catalysts under Accelerated Stress Tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Papadias, D. D.; Ahluwalia, R. K.; Kariuki, N.

    The durability of Pt-Co alloy cathode catalysts supported on high surface area carbon is investigated by subjecting them to accelerated stress tests (ASTs). The catalysts had different initial Co contents and nanoparticle morphologies: a “spongy” porous morphology for the high-Co (H) content catalyst, and a fully alloyed crystalline morphology for the medium-Co (M) and low-Co (L) content catalysts. The specific activity of the catalysts depends on their initial Co content, morphology and nanoparticle size, and remained higher than 1000 μA/cm 2-Pt after 27–50% Co loss. The H-catalyst electrode showed the smallest kinetic overpotentials (η c s) due to higher initialmore » Pt loading than the other two electrodes, but it had the fastest increase in ηcs with AST cycling due to lower Co retention; the L-catalyst electrode showed higher η c s due to a lower initial Pt loading, but had a smaller increase in η c s with aging due to higher Co retention; the M-catalyst electrode showed a similar increase in η c s with aging, but this increase was due to the combined effects of Co dissolution and electrochemically active surface area (ECSA) loss. In conclusion, the modeled increase in mass transfer overpotentials with aging correlates with the initial Pt loading, ECSA loss and the initial catalyst morphology« less

  19. Durability of Pt-Co Alloy Polymer Electrolyte Fuel Cell Cathode Catalysts under Accelerated Stress Tests

    DOE PAGES

    Papadias, D. D.; Ahluwalia, R. K.; Kariuki, N.; ...

    2018-03-17

    The durability of Pt-Co alloy cathode catalysts supported on high surface area carbon is investigated by subjecting them to accelerated stress tests (ASTs). The catalysts had different initial Co contents and nanoparticle morphologies: a “spongy” porous morphology for the high-Co (H) content catalyst, and a fully alloyed crystalline morphology for the medium-Co (M) and low-Co (L) content catalysts. The specific activity of the catalysts depends on their initial Co content, morphology and nanoparticle size, and remained higher than 1000 μA/cm 2-Pt after 27–50% Co loss. The H-catalyst electrode showed the smallest kinetic overpotentials (η c s) due to higher initialmore » Pt loading than the other two electrodes, but it had the fastest increase in ηcs with AST cycling due to lower Co retention; the L-catalyst electrode showed higher η c s due to a lower initial Pt loading, but had a smaller increase in η c s with aging due to higher Co retention; the M-catalyst electrode showed a similar increase in η c s with aging, but this increase was due to the combined effects of Co dissolution and electrochemically active surface area (ECSA) loss. In conclusion, the modeled increase in mass transfer overpotentials with aging correlates with the initial Pt loading, ECSA loss and the initial catalyst morphology« less

  20. The effect of sample storage on the performance and reproducibility of the galactomannan EIA test.

    PubMed

    Kimpton, George; White, P Lewis; Barnes, Rosemary A

    2014-08-01

    Galactomannan enzyme immune assay (GM EIA) is a nonculture test for detecting invasive aspergillosis (IA) forming a key part of diagnosis and management. Recent reports have questioned the reproducibility of indices after sample storage. To investigate this, 198 serum samples (72 from cases and 126 from controls) and 61 plasma samples (24 from cases and 37 from controls), initially tested between 2010 and 2013, were retested to determine any change in index. Data were also collected on circulatory protein levels for false-positive serum samples. Serum indices significantly declined on retesting (median: initial, 0.50, retest, 0.23; P < 0.0001). This was shown to be diagnosis dependent as the decline was apparent on retesting of control samples (median: initial 0.50, retest 0.12; P < 0.0001), but was not evident with case samples (median: initial, 0.80, retest, 0.80; P = 0.724). Plasma samples showed little change on reanalysis after long-term storage at 4°C. Retesting after freezing showed a decrease in index values for controls (median: initial 0.40, retest 0.26; P = 0.0505), but no significant change in cases. Circulatory proteins showed a correlation between serum albumin concentration and difference in index value on retesting. Overall, this study suggests that a lack of reproducibility in GM EIA positivity is only significant when disease is absent. Retesting after freezing helps to differentiate false-positive GM EIA results and, with consecutive positivity, could help to improve accuracy in predicting disease status. The freezing of samples prior to testing could potentially reduce false-positivity rates and the need to retest. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Experimental Model of Biofilm Implant-Related Osteomyelitis To Test Combination Biomaterials Using Biofilms as Initial Inocula

    PubMed Central

    Williams, Dustin L.; Haymond, Bryan S.; Woodbury, Kassie L.; Beck, J. Peter; Moore, David E.; Epperson, R. Tyler; Bloebaum, Roy D.

    2012-01-01

    Currently, the majority of animal models that are used to study biofilm-related infections utilize planktonic bacterial cells as initial inocula to produce positive signals of infection in biomaterials studies. However, the use of planktonic cells has potentially led to inconsistent results in infection outcomes. In this study, well-established biofilms of methicillin-resistant Staphylococcus aureus (MRSA) were grown and used as initial inocula in an animal model of a Type IIIB open fracture. The goal of the work was to establish, for the first time, a repeatable model of biofilm implant-related osteomyelitis wherein biofilms were used as initial inocula to test combination biomaterials. Results showed that 100% of animals that were treated with biofilms developed osteomyelitis, whereas 0% of animals not treated with biofilm developed infection. The development of this experimental model may lead to an important shift in biofilm and biomaterials research by showing that when biofilms are used as initial inocula, they may provide additional insights into how biofilm-related infections in the clinic develop and how they can be treated with combination biomaterials to eradicate and/or prevent biofilm formation. PMID:22492534

  2. Experimental model of biofilm implant-related osteomyelitis to test combination biomaterials using biofilms as initial inocula.

    PubMed

    Williams, Dustin L; Haymond, Bryan S; Woodbury, Kassie L; Beck, J Peter; Moore, David E; Epperson, R Tyler; Bloebaum, Roy D

    2012-07-01

    Currently, the majority of animal models that are used to study biofilm-related infections use planktonic bacterial cells as initial inocula to produce positive signals of infection in biomaterials studies. However, the use of planktonic cells has potentially led to inconsistent results in infection outcomes. In this study, well-established biofilms of methicillin-resistant Staphylococcus aureus were grown and used as initial inocula in an animal model of a Type IIIB open fracture. The goal of the work was to establish, for the first time, a repeatable model of biofilm implant-related osteomyelitis, wherein biofilms were used as initial inocula to test combination biomaterials. Results showed that 100% of animals that were treated with biofilms developed osteomyelitis, whereas 0% of animals not treated with biofilm developed infection. The development of this experimental model may lead to an important shift in biofilm and biomaterials research by showing that when biofilms are used as initial inocula, they may provide additional insights into how biofilm-related infections in the clinic develop and how they can be treated with combination biomaterials to eradicate and/or prevent biofilm formation. Copyright © 2012 Wiley Periodicals, Inc.

  3. 49 CFR 40.3 - What do the terms used in this part mean?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... one that requires further testing for drugs or drug metabolites. Initial specimen validity test. The... specimen. A specimen that has been altered, as evidenced by test results showing either a substance that is... endogenous substance. Affiliate. Persons are affiliates of one another if, directly or indirectly, one...

  4. A Comparative Study of Interval Management Control Law Capabilities

    NASA Technical Reports Server (NTRS)

    Barmore, Bryan E.; Smith, Colin L.; Palmer, Susan O.; Abbott, Terence S.

    2012-01-01

    This paper presents a new tool designed to allow for rapid development and testing of different control algorithms for airborne spacing. This tool, Interval Management Modeling and Spacing Tool (IM MAST), is a fast-time, low-fidelity tool created to model the approach of aircraft to a runway, with a focus on their interactions with each other. Errors can be induced between pairs of aircraft by varying initial positions, winds, speed profiles, and altitude profiles. Results to-date show that only a few of the algorithms tested had poor behavior in the arrival and approach environment. The majority of the algorithms showed only minimal variation in performance under the test conditions. Trajectory-based algorithms showed high susceptibility to wind forecast errors, while performing marginally better than the other algorithms under other conditions. Trajectory-based algorithms have a sizable advantage, however, of being able to perform relative spacing operations between aircraft on different arrival routes and flight profiles without employing ghosting. methods. This comes at the higher cost of substantially increased complexity, however. Additionally, it was shown that earlier initiation of relative spacing operations provided more time for corrections to be made without any significant problems in the spacing operation itself. Initiating spacing farther out, however, would require more of the aircraft to begin spacing before they merge onto a common route.

  5. Sonographic Findings in Necrotizing Fasciitis: Two Ends of the Spectrum.

    PubMed

    Shyy, William; Knight, Roneesha S; Goldstein, Ruth; Isaacs, Eric D; Teismann, Nathan A

    2016-10-01

    Necrotizing fasciitis is a rare but serious disease, and early diagnosis is essential to reducing its substantial morbidity and mortality. The 2 cases presented show that the key clinical and radiographic features of necrotizing fasciitis exist along a continuum of severity at initial presentation; thus, this diagnosis should not be prematurely ruled out in cases that do not show the dramatic features familiar to most clinicians. Although computed tomography and magnetic resonance imaging are considered the most effective imaging modalities, the cases described here illustrate how sonography should be recommended as an initial imaging test to make a rapid diagnosis and initiate therapy.

  6. PhoneSat: Ground Testing of a Phone-Based Prototype Bus

    NASA Technical Reports Server (NTRS)

    Felix, Carmen; Howard, Benjamin; Reyes, Matthew; Snarskiy, Fedor; Hickman, Ryan; Boshuizen, Christopher; Marshall, William

    2010-01-01

    Most of the key capabilities that are requisite of a satellite bus are housed in today's smart phones. PhoneSat refers to an initiative to build a ground-based prototype vehicle that could all the basic functionality of a satellite, including attitude control, using a smart Phone as its central hardware. All components used were also low cost Commercial off the Shelf (COTS). In summer 2009, an initial prototype was created using the LEGO Mindstorm toolkit demonstrating simple attitude control. Here we report on a follow up initiative to design, build and test a vehicle based on the Google s smart phone Nexus One. The report includes results from initial thermal-vacuum chamber tests and low altitude sub-orbital rocket flights which show that, at least for short durations, the Nexus One phone is able to withstand key aspects of the space environment without failure. We compare the sensor data from the Phone's accelerometers and magnetometers with that of an external microelectronic inertial measurement unit.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhai, Ziqing; Kruska, Karen; Toloczko, Mychailo B.

    Stress corrosion crack initiation of two thermally-treated, cold-worked (CW) alloy 690 materials was investigated in 360oC simulated PWR primary water using constant load tensile (CLT) tests and blunt notch compact tension (BNCT) tests equipped with direct current potential drop (DCPD) for in-situ detection of cracking. SCC initiation was not detected by DCPD for the 21% and 31%CW CLT specimens loaded at their yield stress after ~9,220 h, however intergranular (IG) precursor damage and isolated surface cracks were observed on the specimens. The two 31%CW BNCT specimens loaded at moderate stress intensity after several cyclic loading ramps showed DCPD-indicated crack initiationmore » after 10,400h exposure at constant stress intensity, which resulted from significant growth of IG cracks. The 21%CW BNCT specimens only exhibited isolated small IG surface cracks and showed no apparent DCPD change throughout the test. Interestingly, post-test cross-section examinations revealed many grain boundary (GB) nano-cavities in the bulk of all the CLT and BNCT specimens particularly for the 31%CW materials. Cavities were also found along GBs extending to the surface suggesting an important role in crack nucleation. This paper provides an overview of the evolution of GB cavities and will discuss their effects on crack initiation in CW alloy 690.« less

  8. Not New, but Nearly Forgotten: The Testing Effect Decreases or Even Disappears as the Complexity of Learning Materials Increases

    ERIC Educational Resources Information Center

    van Gog, Tamara; Sweller, John

    2015-01-01

    The testing effect is a finding from cognitive psychology with relevance for education. It shows that after an initial study period, taking a practice test improves long-term retention compared to not taking a test and--more interestingly--compared to restudying the learning material. Boundary conditions of the effect that have received attention…

  9. Fatigue crack identification method based on strain amplitude changing

    NASA Astrophysics Data System (ADS)

    Guo, Tiancai; Gao, Jun; Wang, Yonghong; Xu, Youliang

    2017-09-01

    Aiming at the difficulties in identifying the location and time of crack initiation in the castings of helicopter transmission system during fatigue tests, by introducing the classification diagnostic criteria of similar failure mode to find out the similarity of fatigue crack initiation among castings, an engineering method and quantitative criterion for detecting fatigue cracks based on strain amplitude changing is proposed. This method is applied on the fatigue test of a gearbox housing, whose results indicates: during the fatigue test, the system alarms when SC strain meter reaches the quantitative criterion. The afterwards check shows that a fatigue crack less than 5mm is found at the corresponding location of SC strain meter. The test result proves that the method can provide accurate test data for strength life analysis.

  10. (Re)evaluating the Implications of the Autoregressive Latent Trajectory Model Through Likelihood Ratio Tests of Its Initial Conditions.

    PubMed

    Ou, Lu; Chow, Sy-Miin; Ji, Linying; Molenaar, Peter C M

    2017-01-01

    The autoregressive latent trajectory (ALT) model synthesizes the autoregressive model and the latent growth curve model. The ALT model is flexible enough to produce a variety of discrepant model-implied change trajectories. While some researchers consider this a virtue, others have cautioned that this may confound interpretations of the model's parameters. In this article, we show that some-but not all-of these interpretational difficulties may be clarified mathematically and tested explicitly via likelihood ratio tests (LRTs) imposed on the initial conditions of the model. We show analytically the nested relations among three variants of the ALT model and the constraints needed to establish equivalences. A Monte Carlo simulation study indicated that LRTs, particularly when used in combination with information criterion measures, can allow researchers to test targeted hypotheses about the functional forms of the change process under study. We further demonstrate when and how such tests may justifiably be used to facilitate our understanding of the underlying process of change using a subsample (N = 3,995) of longitudinal family income data from the National Longitudinal Survey of Youth.

  11. APOL1 allelic variants are associated with lower age of dialysis initiation and thereby increased dialysis vintage in African and Hispanic Americans with non-diabetic end-stage kidney disease.

    PubMed

    Tzur, Shay; Rosset, Saharon; Skorecki, Karl; Wasser, Walter G

    2012-04-01

    The APOL1 G1 and G2 genetic variants make a major contribution to the African ancestry risk for a number of common forms of non-diabetic end-stage kidney disease (ESKD). We sought to clarify the relationship of APOL1 variants with age of dialysis initiation and dialysis vintage (defined by the time between dialysis initiation and sample collection) in African and Hispanic Americans, diabetic and non-diabetic ESKD. We examined APOL1 genotypes in 995 African and Hispanic American dialysis patients with diabetic and non-diabetic ESKD. The mean age of dialysis initiation for non-diabetic African-American patients with two APOL1 risk alleles was 48.1 years, >9 years earlier than those without APOL1 risk alleles (t-test, P=0.0003). Similar results were found in the non-diabetic Hispanic American cohort, but not in the diabetic cohorts. G1 heterozygotes showed a 5.3-year lower mean age of dialysis initiation (t-test, P=0.0452), but G2 heterozygotes did not show such an effect. At the age of 70, 92% of individuals with two APOL1 risk alleles had already initiated dialysis, compared with 76% of the patients without APOL1 risk alleles. Although two APOL1 risk alleles are also associated with ∼2 years increased in dialysis vintage, further analysis showed that this increase is fully explained by earlier age of dialysis initiation. Two APOL1 risk alleles significantly predict lower age of dialysis initiation and thereby increased dialysis vintage in non-diabetic ESKD African and Hispanic Americans, but not in diabetic ESKD. A single APOL1 G1, but not G2, risk allele also lowers the age of dialysis initiation, apparently consistent with gain of injury or loss of function mechanisms. Hence, APOL1 mutations produce a distinct category of kidney disease that manifests at younger ages in African ancestry populations.

  12. Restructurable VLSI Program

    DTIC Science & Technology

    1981-03-31

    logic testing element and a concomitant testability criterion ideally suited to dynamic circuit applications and appro- priate for automatic computer...making connections automatically . PF is an experimental feature which provides users with only four different chip sizes (full, half, quarter, and eighth...initial solution is found constructively which is improved by pair-wise swapping. Results show, however, that the constructive initial sorter , which

  13. Anti-Armor, Confined Space, Reduced Sensitivity (AT4CS-RS) Insensitive Munitions (IM) Effort: Summary and Conclusions

    DTIC Science & Technology

    An effort was initiated to develop an insensitive munitions packaging solution for the AT4CS-RS.The effort investigated several promising designs...Initial engineering testing showed that the most promising design is the deflection plate concept, which will achieve a type IV reaction for Slow Cook

  14. Effects of rational-emotive therapy on psychophysiological and reported measures of test anxiety arousal.

    PubMed

    Barabasz, A F; Barabasz, M

    1981-07-01

    Developed audio taped lectures, taped therapy session models, and homework assignments designed to reduce irrational beliefs associated with test anxiety within Ellis' rational-emotive therapy (RET) approach. The initial sample consisted of 148 university students. Comparisons with an attention placebo counseling program, which was established to be equally credible by a post-experiment inquiry and a no-treatment group found the RET Ss to show significantly lower skin conductance responses to a test anxiety visualization and lower reported anxiety on a questionnaire. However, skin conductance responses to an alternative test anxiety visualization did not show treatment effects.

  15. Performance of the Lester battery charger in electric vehicles

    NASA Technical Reports Server (NTRS)

    Vivian, H. C.; Bryant, J. A.

    1984-01-01

    Tests are performed on an improved battery charger. The primary purpose of the testing is to develop test methodologies for battery charger evaluation. Tests are developed to characterize the charger in terms of its charge algorithm and to assess the effects of battery initial state of charge and temperature on charger and battery efficiency. Tests show this charger to be a considerable improvement in the state of the art for electric vehicle chargers.

  16. Wolff-Parkinson-White syndrome: a single exercise stress test might be misleading.

    PubMed

    Salavitabar, Arash; Silver, Eric S; Liberman, Leonardo

    2017-05-01

    Risk stratification of patients with Wolff-Parkinson-White syndrome for sudden death is a complex process, particularly in understanding the utility of the repeat exercise stress test. We report a case of an 18-year-old patient who was found to have a high-risk pathway by both invasive and exercise stress testing after an initial exercise stress test showing beat-to-beat loss of pre-excitation.

  17. Effects of Aggregation on Blood Sedimentation and Conductivity

    PubMed Central

    Zhbanov, Alexander; Yang, Sung

    2015-01-01

    The erythrocyte sedimentation rate (ESR) test has been used for over a century. The Westergren method is routinely used in a variety of clinics. However, the mechanism of erythrocyte sedimentation remains unclear, and the 60 min required for the test seems excessive. We investigated the effects of cell aggregation during blood sedimentation and electrical conductivity at different hematocrits. A sample of blood was drop cast into a small chamber with two planar electrodes placed on the bottom. The measured blood conductivity increased slightly during the first minute and decreased thereafter. We explored various methods of enhancing or retarding the erythrocyte aggregation. Using experimental measurements and theoretical calculations, we show that the initial increase in blood conductivity was indeed caused by aggregation, while the subsequent decrease in conductivity resulted from the deposition of erythrocytes. We present a method for calculating blood conductivity based on effective medium theory. Erythrocytes are modeled as conducting spheroids surrounded by a thin insulating membrane. A digital camera was used to investigate the erythrocyte sedimentation behavior and the distribution of the cell volume fraction in a capillary tube. Experimental observations and theoretical estimations of the settling velocity are provided. We experimentally demonstrate that the disaggregated cells settle much slower than the aggregated cells. We show that our method of measuring the electrical conductivity credibly reflected the ESR. The method was very sensitive to the initial stage of aggregation and sedimentation, while the sedimentation curve for the Westergren ESR test has a very mild slope in the initial time. We tested our method for rapid estimation of the Westergren ESR. We show a correlation between our method of measuring changes in blood conductivity and standard Westergren ESR method. In the future, our method could be examined as a potential means of accelerating ESR tests in clinical practice. PMID:26047511

  18. Bullet Impact Safety Study of PBX-9502

    NASA Astrophysics Data System (ADS)

    Ferranti, Louis

    2013-06-01

    A new small arms capability for performing bullet impact testing into energetic materials has recently been activated at Lawrence Livermore National Laboratory located in the High Explosives Applications Facility (HEAF). The initial capability includes 0.223, 0.30, and 0.50 testing calibers with the flexibility to add other barrels in the near future. An initial test series has been performed using the 0.50 caliber barrel shooting bullets into targets using the TATB based explosive PBX-9502 and shows an expected non-violent reaction. Future experiments to evaluate the safety of new explosive formulations to bullet impact are planned. A highlight of the new capability along with discussion of the initial experiments to date will be presented including future areas of research. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  19. Assessment of auditory skills in 140 cochlear implant children using the EARS protocol.

    PubMed

    Sainz, Manuel; Skarzynski, Henryk; Allum, John H J; Helms, Jan; Rivas, Adriana; Martin, Jane; Zorowka, Patrick Georg; Phillips, Lucy; Delauney, Joseph; Brockmeyer, Steffi Johanna; Kompis, Martin; Korolewa, Inna; Albegger, Klaus; Zwirner, Petra; Van De Heyning, Paul; D'Haese, Patrick

    2003-01-01

    Auditory performance of cochlear implant (CI) children was assessed with the Listening Progress Profile (LiP) and the Monosyllabic-Trochee-Polysyllabic-Word Test (MTP) following the EARS protocol. Additionally, the 'initial drop' phenomenon, a recently reported decrease of auditory performance occurring immediately after first fitting, was investigated. Patients were 140 prelingually deafened children from various clinics and centers worldwide implanted with a MEDEL COMBI 40/40+. Analysis of LiP data showed a significant increase after 1 month of CI use compared to preoperative scores (p < 0.01). No initial decrease was observed with this test. Analysis of MTP data revealed a significant improvement of word recognition after 6 months (p < 0.01), with a significant temporary decrease after initial fitting (p < 0.01). With both tests, children's auditory skills improved up to 2 years. Amount of improvement was negatively correlated with age at implantation. Copyright 2003 S. Karger AG, Basel

  20. [Unipedal stance time and fall risk in the elderly].

    PubMed

    Domínguez-Carrillo, Luis Gerardo; Arellano-Aguilar, Gregorio; Leos-Zierold, Héctor

    2007-01-01

    We undertook this study to relate unipodal stance time (UST) as a falls indicator in the elderly and to corroborate with UST exercise increments. One hundred sixty eight elderly subjects (age >70 years) with two or more falls during the previous 12 months were compared with 150 similar subjects without falls. UST chronometry and quadriceps and triceps brachialis strength dynamometry were used. Equilibrium and antigravity muscle-strengthening exercise program with 20 work sessions were carried out. Results were analyzed with chi(2), Student's t-test, and Fisher tests. UST of the control group showed 28.84 +/- 4.73 sec (mean +/- SD). The UST sample showed 19.18 +/- 4.24 sec. The test was initially impossible to carry out in 42 cases (p = 0.05). The final evaluation showed 142 cases with 30 sec of UST (p = 0.00001), isometric force increased in 70% and 30%, respectively (p = 0.05). At 6-month follow-up, 53 falls were reported, 29 were in patients who could not accomplish UST measurement on initial evaluation. UST <30 sec is an indicator of falls in elderly people, and exercise programs increase UST.

  1. Initial Investigation into the Psychoacoustic Properties of Small Unmanned Aerial System Noise

    NASA Technical Reports Server (NTRS)

    Christian, Andrew; Cabell, Randolph

    2017-01-01

    For the past several years, researchers at NASA Langley have been engaged in a series of projects to study the degree to which existing facilities and capabilities, originally created for work on full-scale aircraft, are extensible to smaller scales --those of the small unmanned aerial systems (sUAS, also UAVs and, colloquially, `drones') that have been showing up in the nation's airspace of late. This paper follows an e ort that has led to an initial human{subject psychoacoustic test regarding the annoyance generated by sUAS noise. This e ort spans three phases: 1. The collection of the sounds through field recordings. 2. The formulation and execution of a psychoacoustic test using those recordings. 3. The initial analysis of the data from that test. The data suggests a lack of parity between the noise of the recorded sUAS and that of a set of road vehicles that were also recorded and included in the test, as measured by a set of contemporary noise metrics. Future work, including the possibility of further human subject testing, is discussed in light of this suggestion.

  2. Improvement in smile esthetics following orthodontic treatment: a retrospective study utilizing standardized smile analysis.

    PubMed

    Maganzini, Anthony L; Schroetter, Sarah B; Freeman, Kathy

    2014-05-01

    To quantify smile esthetics following orthodontic treatment and determine whether these changes are correlated to the severity of the initial malocclusion. A standardized smile mesh analysis that evaluated nine lip-tooth characteristics was applied to two groups of successfully treated patients: group 1 (initial American Board of Orthodontics Discrepancy Index [DI] score<20) and group 2 (initial DI score>20). T-tests were used to detect significant differences between the low-DI and high-DI groups for baseline pretreatment measurements, baseline posttreatment measurements, and changes from pre- to posttreatment. A Spearman correlation test compared the initial DI values with the changes in the nine smile measurements. Five of the smile measurements were improved in both groups following orthodontic treatment. Both groups demonstrated improved incisor exposure, an improved gingival smile line, an increase in smile width, a decreased buccal corridor space, and an improvement in smile consonance. Spearman correlation tests showed that initial DI value was not correlated to changes in any of the individual smile measurements. Smile esthetics is improved by orthodontic treatment regardless of the initial severity of the malocclusion. In other words, patients with more complex orthodontic issues and their counterparts with minor malocclusions benefitted equally from treatment in terms of their smile esthetics.

  3. Advanced Gas Turbine (AGT) powertrain system development for automotive applications

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Rotor dynamic instability investigations were conducted. Forward ball bearing hydraulic mount configurations were tested with little effect. Trial assembly of S/N 002 ceramic engine was initiated. Impeller design activities were completed on the straight line element (SLE) blade definition to address near-net-shape powder metal die forging. Performance characteristics of the Baseline Test 2A impeller were closely preserved. The modified blading design has been released for tooling procurement. Developmental testing of the diffusion flame combustor (DFC) for initial use in the S/N 002 2100 F ceramic structures engine was completed. A natural gas slave preheater was designed and fabricated. Preliminary regenerator static seal rig testing showed a significant reduction in leakage and sensitivity to stack height. Ceramic screening tests were completed and two complete sets of ceramic static structures were qualified for engine testing. Efforts on rotor dynamics development to resolve subsynchronous motion were continued.

  4. Divided attention improves delayed, but not immediate retrieval of a consolidated memory.

    PubMed

    Kessler, Yoav; Vandermorris, Susan; Gopie, Nigel; Daros, Alexander; Winocur, Gordon; Moscovitch, Morris

    2014-01-01

    A well-documented dissociation between memory encoding and retrieval concerns the role of attention in the two processes. The typical finding is that divided attention (DA) during encoding impairs future memory, but retrieval is relatively robust to attentional manipulations. However, memory research in the past 20 years had demonstrated that retrieval is a memory-changing process, in which the strength and availability of information are modified by various characteristics of the retrieval process. Based on this logic, several studies examined the effects of DA during retrieval (Test 1) on a future memory test (Test 2). These studies yielded inconsistent results. The present study examined the role of memory consolidation in accounting for the after-effect of DA during retrieval. Initial learning required a classification of visual stimuli, and hence involved incidental learning. Test 1 was administered 24 hours after initial learning, and therefore required retrieval of consolidated information. Test 2 was administered either immediately following Test 1 or after a 24-hour delay. Our results show that the effect of DA on Test 2 depended on this delay. DA during Test 1 did not affect performance on Test 2 when it was administered immediately, but improved performance when Test 2 was given 24-hours later. The results are consistent with other findings showing long-term benefits of retrieval difficulty. Implications for theories of reconsolidation in human episodic memory are discussed.

  5. Self-initiated object-location memory in young and older adults.

    PubMed

    Berger-Mandelbaum, Anat; Magen, Hagit

    2017-11-20

    The present study explored self-initiated object-location memory in ecological contexts, as aspect of memory that is largely absent from the research literature. Young and older adults memorized objects-location associations they selected themselves or object-location associations provided to them, and elaborated on the strategy they used when selecting the locations themselves. Retrieval took place 30 min and 1 month after encoding. The results showed an age-related decline in self-initiated and provided object-location memory. Older adults benefited from self-initiation more than young adults when tested after 30 min, while the benefit was equal when tested after 1 month. Furthermore, elaboration enhanced memory only in older adults, and only after 30 min. Both age groups used deep encoding strategies on the majority of the trials, but their percentage was lower in older adults. Overall, the study demonstrated the processes involved in self-initiated object-location memory, which is an essential part of everyday functioning.

  6. Influence of mobile air-conditioning on vehicle emissions and fuel consumption: a model approach for modern gasoline cars used in Europe.

    PubMed

    Weilenmann, Martin F; Vasic, Ana-Marija; Stettler, Peter; Novak, Philippe

    2005-12-15

    The influence of air-conditioning activity on the emissions and fuel consumption of passenger cars is an important issue, since fleet penetration and use of these systems have reached a high level. Apart from the MOBILE6 study in the United States, little data is available on the impact of air-conditioning devices (A/Cs). Since weather conditions and A/C technologies both differ from those in the U. S., a test series was designed for the European setting. A fleet of six modern gasoline passenger cars was tested in different weather conditions. Separate test series were carried out for the initial cooldown and for the stationary situation of keeping the interior of the vehicle cool. As assumed, CO2 emissions and fuel consumption rise with the thermal load. This also causes a notable rise in CO and hydrocarbons (HCs). Moreover, A/Cs do not stop automatically at low ambient temperatures; if necessary, they produce dry air to demist the windscreen. A model is proposed that shows a constant load for lower temperatures and a linear trend for higher temperatures. The initial cooldown tests highlight significant differences among cars but show that A/C operation for the initial cooling of an overheated passenger compartment does not result in any extra emissions for the fleet as a whole.

  7. Testing Dialog-Verification of SIP Phones with Single-Message Denial-of-Service Attacks

    NASA Astrophysics Data System (ADS)

    Seedorf, Jan; Beckers, Kristian; Huici, Felipe

    The Session Initiation Protocol (SIP) is widely used for signaling in multimedia communications. However, many SIP implementations are still in their infancy and vulnerable to malicious messages. We investigate flaws in the SIP implementations of eight phones, showing that the deficient verification of SIP dialogs further aggravates the problem by making it easier for attacks to succeed. Our results show that the majority of the phones we tested are susceptible to these attacks.

  8. Electrostatic N-95 respirator filter media efficiency degradation resulting from intermittent sodium chloride aerosol exposure.

    PubMed

    Moyer, E S; Bergman, M S

    2000-08-01

    The effects of intermittently loading small masses of sodium chloride aerosol on the filtration efficiency of N-95 filtering facepiece respirators was investigated. The National Institute for Occupational Safety and Health (NIOSH) certifies that N-95 respirators must provide at least 95 percent filtration efficiency against a sodium chloride aerosol challenge as per the respirator certification (42 CFR 84) test criteria. N-95 respirators are specified for protection against solid and water-based particulates (i.e., non-oil aerosols). New N-95 respirators from three different manufacturers were loaded with 5 +/- 1 mg of sodium chloride aerosol one day a week, over a period of weeks. Aerosol loading and penetration measurements were performed using the TSI 8130 Filter Tester. Respirators were stored uncovered on an office desktop outside the laboratory. To investigate environmental and temporal effects of filters being stored without sodium chloride exposure, control respirators were stored on the desk for various lengths of time before being initiated into weekly testing. For all manufacturers' respirators, the controls showed similar initial penetrations on their day of initiation (day zero) to those of the study samples on day zero. As the controls were tested weekly, they showed similar degradation rates to those of the study samples. Results show that some of the manufacturers' models had penetrations of greater than 5 percent when intermittently exposed to sodium chloride aerosol. It is concluded that intermittent, low-level sodium chloride aerosol loading of N-95 respirators has a degrading effect on filter efficiency. This reduction in filter efficiency was not accompanied by a significant increase in breathing resistance that would signal the user that the filter needs to be replaced. Furthermore, it was noted that the effect of room storage time prior to initial exposure was much less significant.

  9. Using Item Response Theory to Describe the Nonverbal Literacy Assessment (NVLA)

    ERIC Educational Resources Information Center

    Fleming, Danielle; Wilson, Mark; Ahlgrim-Delzell, Lynn

    2018-01-01

    The Nonverbal Literacy Assessment (NVLA) is a literacy assessment designed for students with significant intellectual disabilities. The 218-item test was initially examined using confirmatory factor analysis. This method showed that the test worked as expected, but the items loaded onto a single factor. This article uses item response theory to…

  10. Integrated Thermal Modules for Cooling Silicon and Silicon Carbide Power Modules

    DTIC Science & Technology

    2007-06-11

    analyses, bench tests, and motor tests comprise the program. The ITMs, in place of standard heatsinks, use a highly conductive pyrolytic graphite to...passively cool power modules. Initial results show that even simple ITMs can lower chip temperatures by 20 deg. C and 10 deg. C with engine oil and

  11. Precursor Evolution and Stress Corrosion Cracking Initiation of Cold-Worked Alloy 690 in Simulated Pressurized Water Reactor Primary Water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhai, Ziqing; Toloczko, Mychailo; Kruska, Karen

    Stress corrosion crack initiation of two thermally-treated, cold-worked (CW) alloy 690 (UNS N06690) materials was investigated in 360oC simulated PWR primary water using constant load tensile (CLT) tests and blunt notch compact tension (BNCT) tests equipped with direct current potential drop (DCPD) for in-situ detection of cracking. SCC initiation was not detected by DCPD for either the 21% or 31%CW CLT specimens loaded at their yield stress after ~9,220 hours, however intergranular (IG) precursor damage and isolated surface cracks were observed on the specimens. The two 31%CW BNCT specimens loaded at moderate stress intensity after several cyclic loading ramps showedmore » DCPD-indicated crack initiation after 10,400 hours of exposure at constant stress intensity, which was resulted from significant growth of IG cracks. The 21%CW BNCT specimens only exhibited isolated small IG surface cracks and showed no apparent DCPD change throughout the test. Post-test cross-section examinations revealed many grain boundary (GB) nano-cavities in the bulk of all the CLT and BNCT specimens particularly for the 31%CW materials. Cavities were also found along GBs extending to the surface suggesting an important role in crack nucleation. This paper provides an overview of the evolution of GB cavities and discusses their effects on crack initiation in CW alloy 690.« less

  12. Patient and Societal Value Functions for the Testing Morbidities Index

    PubMed Central

    Swan, John Shannon; Kong, Chung Yin; Lee, Janie M.; Akinyemi, Omosalewa; Halpern, Elkan F.; Lee, Pablo; Vavinskiy, Sergey; Williams, Olubunmi; Zoltick, Emilie S.; Donelan, Karen

    2013-01-01

    Background We developed preference-based and summated scale scoring for the Testing Morbidities Index (TMI) classification, which addresses short-term effects on quality of life from diagnostic testing before, during and after a testing procedure. Methods The two TMI value functions utilize multiattribute value techniques; one is patient-based and the other has a societal perspective. 206 breast biopsy patients and 466 (societal) subjects informed the models. Due to a lack of standard short-term methods for this application, we utilized the visual analog scale (VAS). Waiting trade-off (WTO) tolls provided an additional option for linear transformation of the TMI. We randomized participants to one of three surveys: the first derived weights for generic testing morbidity attributes and levels of severity with the VAS; a second developed VAS values and WTO tolls for linear transformation of the TMI to a death-healthy scale; the third addressed initial validation in a specific test (breast biopsy). 188 patients and 425 community subjects participated in initial validation, comparing direct VAS and WTO values to the TMI. Alternative TMI scoring as a non-preference summated scale was included, given evidence of construct and content validity. Results The patient model can use an additive function, while the societal model is multiplicative. Direct VAS and the VAS-scaled TMI were correlated across modeling groups (r=0.45 to 0.62) and agreement was comparable to the value function validation of the Health Utilities Index 2. Mean Absolute Difference (MAD) calculations showed a range of 0.07–0.10 in patients and 0.11–0.17 in subjects. MAD for direct WTO tolls compared to the WTO-scaled TMI varied closely around one quality-adjusted life day. Conclusions The TMI shows initial promise in measuring short-term testing-related health states. PMID:23689044

  13. High-Resolution Mesoscale Simulations of the 6-7 May 2000 Missouri Flash Flood: Impact of Model Initialization and Land Surface Treatment

    NASA Technical Reports Server (NTRS)

    Baker, R. David; Wang, Yansen; Tao, Wei-Kuo; Wetzel, Peter; Belcher, Larry R.

    2004-01-01

    High-resolution mesoscale model simulations of the 6-7 May 2000 Missouri flash flood event were performed to test the impact of model initialization and land surface treatment on timing, intensity, and location of extreme precipitation. In this flash flood event, a mesoscale convective system (MCS) produced over 340 mm of rain in roughly 9 hours in some locations. Two different types of model initialization were employed: 1) NCEP global reanalysis with 2.5-degree grid spacing and 12-hour temporal resolution, and 2) Eta reanalysis with 40- km grid spacing and $hour temporal resolution. In addition, two different land surface treatments were considered. A simple land scheme. (SLAB) keeps soil moisture fixed at initial values throughout the simulation, while a more sophisticated land model (PLACE) allows for r interactive feedback. Simulations with high-resolution Eta model initialization show considerable improvement in the intensity of precipitation due to the presence in the initialization of a residual mesoscale convective vortex (hlCV) from a previous MCS. Simulations with the PLACE land model show improved location of heavy precipitation. Since soil moisture can vary over time in the PLACE model, surface energy fluxes exhibit strong spatial gradients. These surface energy flux gradients help produce a strong low-level jet (LLJ) in the correct location. The LLJ then interacts with the cold outflow boundary of the MCS to produce new convective cells. The simulation with both high-resolution model initialization and time-varying soil moisture test reproduces the intensity and location of observed rainfall.

  14. Effect of particle size on droplet infiltration into hydrophobic porous media as a model of water repellent soil.

    PubMed

    Hamlett, Christopher A E; Shirtcliffe, Neil J; McHale, Glen; Ahn, Sujung; Bryant, Robert; Doerr, Stefan H; Newton, Michael I

    2011-11-15

    The wettability of soil is of great importance for plants and soil biota, and in determining the risk for preferential flow, surface runoff, flooding,and soil erosion. The molarity of ethanol droplet (MED) test is widely used for quantifying the severity of water repellency in soils that show reduced wettability and is assumed to be independent of soil particle size. The minimum ethanol concentration at which droplet penetration occurs within a short time (≤ 10 s) provides an estimate of the initial advancing contact angle at which spontaneous wetting is expected. In this study, we test the assumption of particle size independence using a simple model of soil, represented by layers of small (~0.2-2 mm) diameter beads that predict the effect of changing bead radius in the top layer on capillary driven imbibition. Experimental results using a three-layer bead system show broad agreement with the model and demonstrate a dependence of the MED test on particle size. The results show that the critical initial advancing contact angle for penetration can be considerably less than 90° and varies with particle size, demonstrating that a key assumption currently used in the MED testing of soil is not necessarily valid.

  15. Creep rupture testing of alloy 617 and A508/533 base metals and weldments.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Natesan, K.; Li, M.; Soppet, W.K.

    2012-01-17

    The NGNP, which is an advanced HTGR concept with emphasis on both electricity and hydrogen production, involves helium as the coolant and a closed-cycle gas turbine for power generation with a core outlet/gas turbine inlet temperature of 750-1000 C. Alloy 617 is a prime candidate for VHTR structural components such as reactor internals, piping, and heat exchangers in view of its resistance to oxidation and elevated temperature strength. However, lack of adequate data on the performance of the alloy in welded condition prompted to initiate a creep test program at Argonne National Laboratory. In addition, Testing has been initiated tomore » evaluate the creep rupture properties of the pressure vessel steel A508/533 in air and in helium environments. The program, which began in December 2009, was certified for quality assurance NQA-1 requirements during January and February 2010. Specimens were designed and fabricated during March and the tests were initiated in April 2010. During the past year, several creep tests were conducted in air on Alloy 617 base metal and weldment specimens at temperatures of 750, 850, and 950 C. Idaho National Laboratory, using gas tungsten arc welding method with Alloy 617 weld wire, fabricated the weldment specimens. Eight tests were conducted on Alloy 617 base metal specimens and nine were on Alloy 617 weldments. The creep rupture times for the base alloy and weldment tests were up to {approx}3900 and {approx}4500 h, respectively. The results showed that the creep rupture lives of weld specimens are much longer than those for the base alloy, when tested under identical test conditions. The test results also showed that the creep strain at fracture is in the range of 7-18% for weldment samples and were much lower than those for the base alloy, under similar test conditions. In general, the weldment specimens showed more of a flat or constant creep rate region than the base metal specimens. The base alloy and the weldment exhibited tertiary creep after 50-60% of the rupture life, irrespective of test temperature in the range of 750-950 C. The results showed that the stress dependence of the creep rate followed a power law for both base alloy and weldments. The data also showed that the stress exponent for creep is the same and one can infer that the same mechanism is operative in both base metal and weldments in the temperature range of the current study. SEM fractography analysis indicated that both base metal and weldment showed combined fracture modes consisting of dimple rupture and intergranular cracking. Intergranular cracking was more evident in the weldment specimens, which is consistent with the observation of lower creep ductility in the weldment than in the base metal.« less

  16. Online Friendship, Romance, and Sex: Properties and Associations of the Online Relationship Initiation Scale.

    PubMed

    Harris, Keith M; Aboujaoude, Elias

    2016-08-01

    Online relationships are increasingly central to many people's lives. As a result, there is a growing need to scientifically examine their psychosocial implications. This study developed and tested the Online Relationship Initiation Scale (ORIS) through classical and item response theory analyses to address this need. An anonymous online survey included 713 adults, aged 18-71 years. The ORIS was tested on psychometric properties and examined for associations with gender and several standardized psychosocial measures. Results demonstrated unidimensionality of nine items, strong factor loadings, and high internal consistency (α = 0.90, ωt = 0.94). All items captured significant information on the latent trait and none showed differential item functioning by sex, age group, or ethnicity. General linear modeling confirmed hypotheses that men were more likely than women to initiate online relationships. Online relationship initiation was not strongly associated with perceived social support, but was positively related to financial distress, and willingness to engage in infidelity or unprotected sex. The ORIS was negatively associated with age and satisfaction with life and showed modest interactions with ethnicity and hours online. This study provided empirical evidence for an interpersonal relationship initiation construct. The ORIS was shown to be a psychometrically sound instrument for evaluating online interpersonal behaviors and their associations with psychosocial and demographic factors. Such psychometrically sound instruments can be useful in exploring online interpersonal behaviors and their significance.

  17. Pitting Initiation and Propagation of X70 Pipeline Steel Exposed to Chloride-Containing Environments

    PubMed Central

    Yang, Zixuan; Kan, Bo; Li, Jinxu; Su, Yanjing; Qiao, Lijie; Volinsky, Alex A.

    2017-01-01

    Inclusion-induced pitting initiation mechanisms in X70 steel were investigated by scanning electron microscopy, scanning Kelvin probe force microscopy (SKPFM), immersion and electrochemical polarization tests in chloride-containing ion solutions. There are three inclusion types in the X70 steel. Corrosion test results indicated that pitting corrosion resistance of type A inclusion < type C inclusion < type B inclusion, i.e., (Mn, Ca)S < matrix < (Al, Ca)O. SKPFM test results show that the type A inclusion exhibited both lower and higher potentials than the matrix, while the type B inclusion exhibited higher potential than the matrix. The corrosion test and the SKPFM potential test results are consistent. Potentiodynamic polarization results indicate that the type A and C are active inclusions, while the type B is an inactive inclusion. Three kinds of possible mechanisms of inclusion-induced pitting corrosion are established for the X70 steel. PMID:28902156

  18. Automatic detection of multiple UXO-like targets using magnetic anomaly inversion and self-adaptive fuzzy c-means clustering

    NASA Astrophysics Data System (ADS)

    Yin, Gang; Zhang, Yingtang; Fan, Hongbo; Ren, Guoquan; Li, Zhining

    2017-12-01

    We have developed a method for automatically detecting UXO-like targets based on magnetic anomaly inversion and self-adaptive fuzzy c-means clustering. Magnetic anomaly inversion methods are used to estimate the initial locations of multiple UXO-like sources. Although these initial locations have some errors with respect to the real positions, they form dense clouds around the actual positions of the magnetic sources. Then we use the self-adaptive fuzzy c-means clustering algorithm to cluster these initial locations. The estimated number of cluster centroids represents the number of targets and the cluster centroids are regarded as the locations of magnetic targets. Effectiveness of the method has been demonstrated using synthetic datasets. Computational results show that the proposed method can be applied to the case of several UXO-like targets that are randomly scattered within in a confined, shallow subsurface, volume. A field test was carried out to test the validity of the proposed method and the experimental results show that the prearranged magnets can be detected unambiguously and located precisely.

  19. The Role of Manual Encoding in Learning by the Prelingually Deaf: An Initial Investigation.

    ERIC Educational Resources Information Center

    Stall, C. Harmon; Marshall, Philip H.

    1984-01-01

    A study tested the hypothesis that manual encoding aids learning in the prelingually deaf. Twenty-four adults who used fingerspelling as their primary means of communication participated in two groups of a paired-associate learning paradigm, using eight study-test trial sequences. Those using fingerspelling showed more recall and a faster learning…

  20. Fitting the Rasch Model to Account for Variation in Item Discrimination

    ERIC Educational Resources Information Center

    Weitzman, R. A.

    2009-01-01

    Building on the Kelley and Gulliksen versions of classical test theory, this article shows that a logistic model having only a single item parameter can account for varying item discrimination, as well as difficulty, by using item-test correlations to adjust incorrect-correct (0-1) item responses prior to an initial model fit. The fit occurs…

  1. EVALUATION OF FGD DRY INJECTION SORBENTS AND ADDITIVES - VOLUME 2 - PILOT PLANT EVALUATION OF HIGH REACTIVITY SORBENTS

    EPA Science Inventory

    The report describes a mini-pilot test program to investigate potential new sorbents and processes for dry SO2 removal. Initial tests showed that the 85 cu m/h pilot plant could be used successfully to evaluate both spray dryer and dry injection processes using traditional calciu...

  2. Asthma in pregnancy: association between the Asthma Control Test and the Global Initiative for Asthma classification and comparisons with spirometry.

    PubMed

    de Araujo, Georgia Véras; Leite, Débora F B; Rizzo, José A; Sarinho, Emanuel S C

    2016-08-01

    The aim of this study was to identify a possible association between the assessment of clinical asthma control using the Asthma Control Test (ACT) and the Global Initiative for Asthma (GINA) classification and to perform comparisons with values of spirometry. Through this cross-sectional study, 103 pregnant women with asthma were assessed in the period from October 2010 to October 2013 in the asthma pregnancy clinic at the Clinical Hospital of the Federal University of Pernambuco. Questionnaires concerning the level of asthma control were administered using the Global Initiative for Asthma classification, the Asthma Control Test validated for asthmatic expectant mothers and spirometry; all three methods of assessing asthma control were performed during the same visit between the twenty-first and twenty-seventh weeks of pregnancy. There was a significant association between clinical asthma control assessment using the Asthma Control Test and the Global Initiative for Asthma classification (p<0.001). There were also significant associations between the results of the subjective instruments of asthma (the GINA classification and the ACT) and evidence of lung function by spirometry. This study shows that both the Global Initiative for Asthma classification and the Asthma Control Test can be used for asthmatic expectant mothers to assess the clinical control of asthma, especially at the end of the second trimester, which is assumed to be the period of worsening asthma exacerbations during pregnancy. We highlight the importance of the Asthma Control Test as a subjective instrument with easy application, easy interpretation and good reproducibility that does not require spirometry to assess the level of asthma control and can be used in the primary care of asthmatic expectant mothers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Detecting dark energy in orbit: The cosmological chameleon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brax, Philippe; Bruck, Carsten van de; Davis, Anne-Christine

    2004-12-15

    We show that the chameleon scalar field can drive the current phase of cosmic acceleration for a large class of scalar potentials that are also consistent with local tests of gravity. These provide explicit realizations of a quintessence model where the quintessence scalar field couples directly to baryons and dark matter with gravitational strength. We analyze the cosmological evolution of the chameleon field and show the existence of an attractor solution with the chameleon following the minimum of its effective potential. For a wide range of initial conditions, spanning many orders of magnitude in initial chameleon energy density, the attractormore » is reached before nucleosynthesis. Surprisingly, the range of allowed initial conditions leading to a successful cosmology is wider than in normal quintessence. We discuss applications to the cyclic model of the universe and show how the chameleon mechanism weakens some of the constraints on cyclic potentials.« less

  4. The Effect of Porosity on Fatigue of Die Cast AM60

    NASA Astrophysics Data System (ADS)

    Yang, Zhuofei; Kang, Jidong; Wilkinson, David S.

    2016-07-01

    AM60 high-pressure die castings are known to contain significant porosity which can affect fatigue life. We have studied this using samples drawn from prototype AM60 shock towers by conducting strain-controlled fatigue tests accompanied by X-ray computed tomography analysis. The results show that the machined surface is the preferential location for fatigue crack development, with pores close to these surfaces serving as initiation sites. Fatigue life shows a strong inverse correlation with the size of the fatigue-crack-initiating pore. Pore shape and pore orientation also influence the response. A supplemental study on surface roughness shows that porosity is the dominant factor in fatigue. Tomography enables the link between porosity and fatigue crack initiation to be clearly identified. These data are complemented by SEM observations of the fracture surfaces which are generally flat and full of randomly oriented serration patterns but without long-range fatigue striations.

  5. Effect of initial phase on error in electron energy obtained using paraxial approximation for a focused laser pulse in vacuum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Kunwar Pal, E-mail: k-psingh@yahoo.com; Department of Physics, Shri Venkateshwara University, Gajraula, Amroha, Uttar Pradesh 244236; Arya, Rashmi

    2015-09-14

    We have investigated the effect of initial phase on error in electron energy obtained using paraxial approximation to study electron acceleration by a focused laser pulse in vacuum using a three dimensional test-particle simulation code. The error is obtained by comparing the energy of the electron for paraxial approximation and seventh-order correction description of the fields of Gaussian laser. The paraxial approximation predicts wrong laser divergence and wrong electron escape time from the pulse which leads to prediction of higher energy. The error shows strong phase dependence for the electrons lying along the axis of the laser for linearly polarizedmore » laser pulse. The relative error may be significant for some specific values of initial phase even at moderate values of laser spot sizes. The error does not show initial phase dependence for a circularly laser pulse.« less

  6. Evidence that abnormal grain growth precedes fatigue crack initiation in nanocrystalline Ni-Fe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Furnish, Timothy A.; Bufford, Daniel C.; Ren, Fang

    Prior studies on the high-cycle fatigue behavior of nanocrystalline metals have shown that fatigue fracture is associated with abnormal grain growth (AGG). However, those previous studies have been unable to determine if AGG precedes fatigue crack initiation, or vice-versa. The present study shows that AGG indeed occurs prior to crack formation in nanocrystalline Ni-Fe by using a recently developed synchrotron X-ray diffraction modality that has been adapted for in-situ analysis. The technique allows fatigue tests to be interrupted at the initial signs of the AGG process, and subsequent microscopy reveals the precursor damage state preceding crack initiation.

  7. Evidence that abnormal grain growth precedes fatigue crack initiation in nanocrystalline Ni-Fe

    DOE PAGES

    Furnish, Timothy A.; Bufford, Daniel C.; Ren, Fang; ...

    2018-09-06

    Prior studies on the high-cycle fatigue behavior of nanocrystalline metals have shown that fatigue fracture is associated with abnormal grain growth (AGG). However, those previous studies have been unable to determine if AGG precedes fatigue crack initiation, or vice-versa. The present study shows that AGG indeed occurs prior to crack formation in nanocrystalline Ni-Fe by using a recently developed synchrotron X-ray diffraction modality that has been adapted for in-situ analysis. The technique allows fatigue tests to be interrupted at the initial signs of the AGG process, and subsequent microscopy reveals the precursor damage state preceding crack initiation.

  8. Development and validation of a new questionnaire assessing quality of life in adults with hypopituitarism: Adult Hypopituitarism Questionnaire (AHQ).

    PubMed

    Ishii, Hitoshi; Shimatsu, Akira; Okimura, Yasuhiko; Tanaka, Toshiaki; Hizuka, Naomi; Kaji, Hidesuke; Hanew, Kunihiko; Oki, Yutaka; Yamashiro, Sayuri; Takano, Koji; Chihara, Kazuo

    2012-01-01

    To develop and validate the Adult Hypopituitarism Questionnaire (AHQ) as a disease-specific, self-administered questionnaire for evaluation of quality of life (QOL) in adult patients with hypopituitarism. We developed and validated this new questionnaire, using a standardized procedure which included item development, pilot-testing and psychometric validation. Of the patients who participated in psychometric validation, those whose clinical conditions were judged to be stable were asked to answer the survey questionnaire twice, in order to assess test-retest reliability. Content validity of the initial questionnaire was evaluated via two pilot tests. After these tests, we made minor revisions and finalized the initial version of the questionnaire. The questionnaire was constructed with two domains, one psycho-social and the other physical. For psychometric assessment, analyses were performed on the responses of 192 adult patients with various types of hypopituitarism. The intraclass correlations of the respective domains were 0.91 and 0.95, and the Cronbach's alpha coefficients were 0.96 and 0.95, indicating adequate test-retest reliability and internal consistency for each domain. For known-group validity, patients with hypopituitarism due to hypothalamic disorder showed significantly lower scores in 11 out of 13 sub-domains compared to those who had hypopituitarism due to pituitary disorder. Regarding construct validity, the domain structure was found to be almost the same as that initially hypothesized. Exploratory factor analysis (n = 228) demonstrated that each domain consisted of six and seven sub-domains. The AHQ showed good reliability and validity for evaluating QOL in adult patients with hypopituitarism.

  9. Bilateral asymmetry of skin temperature is not related to bilateral asymmetry of crank torque during an incremental cycling exercise to exhaustion

    PubMed Central

    Formenti, Damiano; Ludwig, Nicola; Gargano, Marco; Bosio, Andrea; Rampinini, Ermanno; Alberti, Giampietro

    2018-01-01

    Although moderate relationships (|r| ∼ 0.5) were reported between skin temperature and performance-related variables (e.g., kinetic), it remains unclear whether skin temperature asymmetry reflects muscle force imbalance in cycling. Therefore, the aim of this study was to assess whether a relationship exists between kinetic and thermal asymmetry during a fatiguing exercise. Ten elite cyclists were enrolled and tested on a maximal incremental cycling test. Peak crank torques of both legs were obtained at the initial and final workload. Likewise, bilateral skin temperatures were recorded before and after exercise. Asymmetric indexes were also calculated for kinetic (AIK) and skin temperature (AIT) outcomes. The bilateral peak crank torques showed a larger difference at the final compared to the initial workload (p < 0.05) of the incremental exercise. Conversely, the bilateral skin temperature did not show any differences at both initial and final workload (p > 0.05). Additionally, trivial relationships were reported between AIK and AIT (−0.3 < r < 0.2) at the initial and final workload. The obtained results showed that changes in bilateral kinetic values did not reflect concurrent changes in bilateral skin temperatures. This finding emphasizes the difficulty of associating the asymmetry of skin temperature with those of muscle effort in elite cyclists. Lastly, our study also provided further insights on thermal skin responses during exhaustive cycling exercise in very highly-trained athletes. PMID:29507831

  10. Consequences of germline variation disrupting the constitutional translational initiation codon start sites of MLH1 and BRCA2: use of potential alternative start sites and implications for predicting variant pathogenicity

    PubMed Central

    Parsons, Michael T.; Whiley, Phillip J.; Beesley, Jonathan; Drost, Mark; de Wind, Niels; Thompson, Bryony A.; Marquart, Louise; Hopper, John L.; Jenkins, Mark A.; Brown, Melissa A.; Tucker, Kathy; Warwick, Linda; Buchanan, Daniel D.; Spurdle, Amanda B.

    2014-01-01

    Variants that disrupt the translation initiation sequences in cancer predisposition genes are generally assumed to be deleterious. However few studies have validated these assumptions with functional and clinical data. Two cancer syndrome gene variants likely to affect native translation initiation were identified by clinical genetic testing: MLH1:c.1A>G p.(Met1?) and BRCA2:c.67+3A>G. In vitro GFP-reporter assays were conducted to assess the consequences of translation initiation disruption on alternative downstream initiation codon usage. Analysis of MLH1:c.1A>G p.(Met1?) showed that translation was mostly initiated at an in-frame position 103 nucleotides downstream, but also at two ATG sequences downstream. The protein product encoded by the in-frame transcript initiating from position c.103 showed loss of in vitro mismatch repair activity comparable to known pathogenic mutations. BRCA2:c.67+3A>G was shown by mRNA analysis to result in an aberrantly spliced transcript deleting exon 2 and the consensus ATG site. In the absence of exon 2, translation initiated mostly at an out-of-frame ATG 323 nucleotides downstream, and to a lesser extent at an in-frame ATG 370 nucleotides downstream. Initiation from any of the downstream alternative sites tested in both genes would lead to loss of protein function, but further clinical data is required to confirm if these variants are associated with a high cancer risk. Importantly, our results highlight the need for caution in interpreting the functional and clinical consequences of variation that leads to disruption of the initiation codon, since translation may not necessarily occur from the first downstream alternative start site, or from a single alternative start site. PMID:24302565

  11. Reuse of acid coagulant-recovered drinking waterworks sludge residual to remove phosphorus from wastewater

    NASA Astrophysics Data System (ADS)

    Yang, Lan; Wei, Jie; Zhang, Yumei; Wang, Jianli; Wang, Dongtian

    2014-06-01

    Acid coagulant-recovered drinking waterworks sludge residual (DWSR) is a waste product from drinking waterworks sludge (DWS) treatment with acid for coagulant recovery. In this study, we evaluated DWSR as a potential phosphorus (P) removing material in wastewater treatment by conducting a series of batch and semi-continuous tests. Batch tests were carried out to study the effects of pH, initial concentration, and sludge dose on P removal. Batch test results showed that the P removal efficiency of DWSR was highly dependent on pH. Calcinated DWSR (C-DWSR) performed better in P removal than DWSR due to its higher pH. At an optimum initial pH value of 5-6 and a sludge dose of 10 g/L, the P removal rates of DWSR and DWS decreased from 99% and 93% to 84% and 14%, respectively, and the specific P uptake of DWSR and DWS increased from 0.19 and 0.19 mg P/g to 33.60 and 5.72 mg P/g, respectively, when the initial concentration was increased from 2 to 400 mg/L. The effective minimum sludge doses of DWSR and DWS were 0.5 g/L and 10 g/L, respectively, when the P removal rates of 90% were obtained at an initial concentration of 10 mg/L. Results from semi-continuous test indicated that P removal rates over 99% were quickly achieved for both synthetic and actual wastewater (lake water and domestic sewage). These rates could be maintained over a certain time under a certain operational conditions including sludge dose, feed flow, and initial concentration. The physicochemical properties analysis results showed that the contents of aluminum (Al) and iron (Fe) in DWSR were reduced by 50% and 70%, respectively, compared with DWS. The insoluble Al and Fe hydroxide in DWS converted into soluble Al and Fe in DWSR. Metal leaching test results revealed that little soluble Al and Fe remained in effluent when DWSR was used for P removal. We deduced that chemical precipitation might be the major action for P removal by DWSR and that adsorption played only a marginal role.

  12. A Measurement Plane for Optical Networks to Manage Emergency Events

    NASA Astrophysics Data System (ADS)

    Tego, E.; Carciofi, C.; Grazioso, P.; Petrini, V.; Pompei, S.; Matera, F.; Attanasio, V.; Nastri, E.; Restuccia, E.

    2017-11-01

    In this work, we show a wide geographical area optical network test bed, adopting the mPlane measurement plane for monitoring its performance and to manage software defined network approaches, with some specific tests and procedures dedicated to respond to disaster events and to support emergency networks. Such a test bed includes FTTX accesses, and it is currently implemented to support future 5G wireless services with slicing procedures based on Carrier Ethernet. The characteristics of this platform have been experimentally tested in the case of a damage-causing link failure and traffic congestion, showing a fast reactions to these disastrous events, allowing the user to recharge the initial QoS parameters.

  13. Effect of Chemistry Triangle Oriented Learning Media on Cooperative, Individual and Conventional Method on Chemistry Learning Result

    NASA Astrophysics Data System (ADS)

    Latisma D, L.; Kurniawan, W.; Seprima, S.; Nirbayani, E. S.; Ellizar, E.; Hardeli, H.

    2018-04-01

    The purpose of this study was to see which method are well used with the Chemistry Triangle-oriented learning media. This quasi experimental research involves first grade of senior high school students in six schools namely each two SMA N in Solok city, in Pasaman and two SMKN in Pariaman. The sampling technique was done by Cluster Random Sampling. Data were collected by test and analyzed by one-way anova and Kruskall Wallish test. The results showed that the high school students in Solok learning taught by cooperative method is better than the results of student learning taught by conventional and Individual methods, both for students who have high initial ability and low-ability. Research in SMK showed that the overall student learning outcomes taught by conventional method is better than the student learning outcomes taught by cooperative and individual methods. Student learning outcomes that have high initial ability taught by individual method is better than student learning outcomes that are taught by cooperative method and for students who have low initial ability, there is no difference in student learning outcomes taught by cooperative, individual and conventional methods. Learning in high school in Pasaman showed no significant difference in learning outcomes of the three methods undertaken.

  14. Performance characteristics of an electric vehicle lead-acid battery pack at elevated temperatures

    NASA Technical Reports Server (NTRS)

    Chapman, P.

    1982-01-01

    Discharge testing data electric car battery pack over initial electrolyte temperature variations between 27 and 55 C are presented. The tests were conducted under laboratory conditions and then compared to detailed electric vehicle simulation models. Battery discharge capacity increased with temperature for constant current discharges, and battery energy capacity increased with temperature for constant power discharges. Dynamometer tests of the electric test vehicle showed an increase in range of 25% for the higher electrolyte temperature.

  15. Prediction of fracture initiation in square cup drawing of DP980 using an anisotropic ductile fracture criterion

    NASA Astrophysics Data System (ADS)

    Park, N.; Huh, H.; Yoon, J. W.

    2017-09-01

    This paper deals with the prediction of fracture initiation in square cup drawing of DP980 steel sheet with the thickness of 1.2 mm. In an attempt to consider the influence of material anisotropy on the fracture initiation, an uncoupled anisotropic ductile fracture criterion is developed based on the Lou—Huh ductile fracture criterion. Tensile tests are carried out at different loading directions of 0°, 45°, and 90° to the rolling direction of the sheet using various specimen geometries including pure shear, dog-bone, and flat grooved specimens so as to calibrate the parameters of the proposed fracture criterion. Equivalent plastic strain distribution on the specimen surface is computed using Digital Image Correlation (DIC) method until surface crack initiates. The proposed fracture criterion is implemented into the commercial finite element code ABAQUS/Explicit by developing the Vectorized User-defined MATerial (VUMAT) subroutine which features the non-associated flow rule. Simulation results of the square cup drawing test clearly show that the proposed fracture criterion is capable of predicting the fracture initiation with sufficient accuracy considering the material anisotropy.

  16. [Recovery in aphasia (Part 1)].

    PubMed

    Hojo, K; Watanabe, S; Tasaki, H; Sato, T; Metoki, H; Saito, M

    1985-08-01

    In order to elucidate the factors which have an influence on the prognosis of aphasia, a correlation was studied in 76 right-handed aphasic patients between recovery rates and various factors: i.e. aphasia type, age, educational level, time between onset of aphasia and institution of therapy and initial severity. Initial evaluations on Standard Language Test of Aphasia (SLTA) were obtained within 5 months after the cerebrovascular accident and reevaluations were obtained 3 months after the initial evaluation. Recovery rates were determined by comparing scores of these 2 tests in order to coincide with clinical impression. The results obtained were as follows: Aphasia type: The highest recovery rates were seen in conduction aphasics, followed by amnestic, Wernicke, and Broca aphasics. Global aphasics had significantly lower recovery rates. It was suggested that anarthria in Broca's aphasia and jargon in Wernicke's aphasia had a significant ratarding effect on recovery rates. Age: Age and recovery rates showed a significant negative correlation: younger patients recovered better, and this trend was remarkable in Wernicke aphasics but not Broca aphasics. Education: Patients with more education tended to improve more, and this trend was most remarkable in amnestic aphasics. Time between onset of aphasia and institution of therapy: Time elapsed from onset and recovery rates showed a significant negative correlation; recovery rates decreased as the time interval from onset increased. Initial severity: Correlation between the initial severity of aphasia, measured by the initial SLTA scores and recovery rates was very high; severily affected aphasics recovered to a lesser extent than mildly affected ones and this trend was remarkable in Wernicke and Broca aphasics.

  17. Explosive Model Tarantula V1/JWL++ Calibration of LX-17: #2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Souers, P C; Vitello, P

    2009-05-01

    Tarantula V1 is a kinetic package for reactive flow codes that seeks to describe initiation, failure, dead zones and detonation simultaneously. The most important parameter is P1, the pressure between the initiation and failure regions. Both dead zone formation and failure can be largely controlled with this knob. However, V1 does failure with low settings and dead zones with higher settings, so that it cannot fulfill its purpose in the current format. To this end, V2 is under test. The derivation of the initiation threshold P0 is discussed. The derivation of the initiation pressure-tau curve as an output of Tarantulamore » shows that the initiation package is sound. A desensitization package is also considered.« less

  18. The Collection of Ice in Jet A-1 Fuel Pipes

    NASA Astrophysics Data System (ADS)

    Maloney, Thomas C.

    Ice collection and blockages in fuel systems have been of interest to the aerospace community since their discovery in the late 1950's when a B-52 crashed. A recent growth of interest was provoked by several incidents that occurred within the last few years. This study seeks to understand the underlying principles of ice growth in fuel flow systems. Tests were performed in a recirculated fuel system with a fuel tank that held approximately 115 gallons of Jet A-1 fuel and ice accumulation was observed in two removable test pipes. The setup was in an altitude chamber capable of -60 °F and the experiments involved full scale flow components. Initially, tests were done to better understand the system and variables that effected accumulation. First, initial conditions within the test pipes were varied. Next, pipe geometry, pipe surface properties, initial water content of the fuel and heat transfer from the fuel pipe were varied. As a result of the tests, observations were made about other effects involved in the study. The effects include: the result of sequentially run tests, the effect of the fuel on the freezing temperature of the entrained water, the effect of ice accumulation on pipe welds, and the effect of the test pipe entrance and exit flow conditions on ice accumulation. The results of initial tests were qualitative. Later quantitative tests were done to demonstrate the dependence of temperature, Reynolds number, and heat transfer on ice accumulation. Tests were quantified with a pressure increase across the pipe sections that was normalized by the expected theoretical initial pressure. As a result of these tests the effect of contamination in the fuel was revealed. For ease of reference, the initial tests were called "stage I" and the later tests were called "stage II". The results of stage I showed that accumulation of soft ice was greatest when a layer of hard ice had initially formed on the pipe surface. Stainless steel collected more ice than Teflon® and there was a lack of a preferential accumulation region downstream of a pipe bend. A greater heat transfer from the pipe increased ice accumulation for aluminum that was made rough with 80 grit sand paper, and for Teflon®. Water was shown to collect in the pipe system as the number of tests increased and the freeze temperature of either the hard or soft ice was about 0 °C. Finally, results of "stage I" tests showed that stainless steel pipe welds were a preferred sight for ice to accumulate. Repeatability was done first in stage II and the normalized pressure increase for two 3/42 un-insulated pipe tests were within 7%. Normalized pressure increase across a pipe was shown to increase as Reynolds number decreased. A 50% increase in Reynolds number led to a 40% decrease in characteristic normalized pressure increase (CNPI). Tests were done at three temperatures and ice accumulated the most at -11 °C. The CNPI at -11 °C was about three times greater than the CNPI at -7.4 °C and about sixty times greater than the CNPI at -19.4 C. A greater heat transfer from the fuel pipe increased ice accumulation. For the amount of time that the tests ran, the total normalized pressure increase was about .9 greater for an un-insulated pipe than for an insulated pipe. Contamination in the fuel increased the amount of soft ice that collected in the system. The CNPI for the more contaminated fuel was more than double the case with less contaminated fuel. Possible solutions for the prevention or decrease of ice accumulation in aircraft fuel systems based on the results of this study are insulated pipes, a change in the type of pipe material, a higher fuel flow rate and cleaner fuel. The fuel temperature could also be altered to avoid temperatures where the most ice accumulates.

  19. Stability Analysis of the Planetary System Orbiting Upsilon Andromedae

    NASA Technical Reports Server (NTRS)

    Lissauer, Jack J.; Rivera, Eugenio J.; DeVincenzi, Donald (Technical Monitor)

    2000-01-01

    We present results of long-term numerical orbital integrations designed to test the stability of the three-planet system orbiting Upsilon Andromedae and short-term integrations to test whether mutual perturbations among the planets can be used to determine planetary masses. Our initial conditions are based on the latest fits to the radial velocity data obtained by the planet-search group at Lick Observatory. The new fits result in significantly more stable systems than did the initially announced planetary parameters. An analytic analysis of the star and the two outer planets shows that this subsystem is Hill stable up to five. Our integrations involving all three planets show that the system is stable for at least 100 Myr for up to four. In our simulations, we still see a secular resonance between the outer two planets and in some cases large oscillations in the eccentricity of the inner planet.

  20. Effects of {10-12} Twins on Dynamic Torsional Properties of Extruded AZ31 Magnesium Alloy

    NASA Astrophysics Data System (ADS)

    Lee, Jong Un; Song, Seok Weon; Kim, Yongjin; Kim, Sang-Hoon; Kim, Ye Jin; Park, Sung Hyuk

    2018-03-01

    Effects of initial twins on dynamic torsional properties of extruded AZ31 alloy were investigated by introducing {10-12} twins into it through precompression to 3 and 6% strains along the extrusion direction and performing torsional testing at a strain rate of 1.4 × 103 s-1 using a torsional Kolsky bar system. The as-extruded sample without twins showed higher dynamic torsional properties than the precompressed samples with many initial twins; the maximum shear strength and fracture shear strain decreased with increasing amount of initial twins. In the as-extruded sample, twinning occurred vigorously throughout the gage section of the tubular specimen during high-strain-rate torsional tests, resulting in heavily deformed morphology, many macrocracks, and rough fractured surfaces. The increased amount of initial twins suppressed the twinning behavior and localized the applied torsional deformation; this resulted in an almost unchanged sample shape, no secondary cracks, and a flat fracture plane, thereby deteriorating the dynamic torsional properties of the extruded alloy.

  1. The effects of work engagement and self-efficacy on personal initiative and performance.

    PubMed

    Lisbona, Ana; Palaci, Francisco; Salanova, Marisa; Frese, Michael

    2018-02-01

    Two popular concepts, work engagement and personal initiative, are different but related constructs. This study is based on and extends the Frese and Fay (2001) model of personal initiative (PI) by including work engagement (WE) and self-efficacy as antecedents of PI, and performance as a consequence. Two studies (study 1, with a cross-sectional design using N = 396 participants from 22 organizations, and study 2, with a longitudinal design conducted in two waves with N = 118 participants from 15 organizations) test the hypotheses. Structural equation modeling and the PROCESS SPSS Macro were used to test the hypothesized mediating role of personal initiative in work engagement and performance, and the results show the indirect effect of WE on performance through PI. The results of these two studies confirmed our hypotheses: WE and self-efficacy lead to higher PI, which, in turn, leads to higher performance. In addition to considering WE as an antecedent of PI, the results lead to considering PI as an antecedent of performance.

  2. Isothermal Dendritic Growth Experiment - Science, engineering, and hardware development for USMP space flights

    NASA Technical Reports Server (NTRS)

    Glicksman, M. E.; Hahn, R. C.; Koss, M. B.; Tirmizi, S. H.; Selleck, M. E.; Velosa, A.; Winsa, E.

    1991-01-01

    The Isothermal Dendritic Growth Experiment (IDGE) has been designed to provide microgravity data on dendritic growth for a critical test of theory. This paper updates progress on constructing a crystal growth chamber suitable for space flight. The IDGE chamber is constructed from glass and stainless steel and is hermetically sealed by electron beam welds and glass-metal seals. Initial tests of the chambers sample's melting point plateau show that the new chamber design is capable of preserving the 99.9995 percent purity of succinonitrile. Dendrite growth can be initiated in the center of the IDGE chamber by means of thermo-electric coolers and a capillary injector tube (stinger). The new IDGE chamber is ready for fully integrated tests with the prototype IDGE engineering hardware at NASA's Lewis Research Center.

  3. Initial stability of press-fit acetabular components under rotational forces.

    PubMed

    Fehring, Keith A; Owen, John R; Kurdin, Anton A; Wayne, Jennifer S; Jiranek, William A

    2014-05-01

    The primary goal of this study was to determine the initial press-fit stability in acetabular components without screw fixation. Mechanical testing was performed with the implantation of press-fit acetabular components in cadaveric specimens. No significant difference was found in load to failure testing between 1 and 2 mm of under-reaming. However, there was significant variability in bending forces required to create 150 μm of micromotion ranging from 49.3 N to 214.4 N. This study shows that cups implanted in a press-fit fashion, which are felt to be clinically stable, have high degrees of variability in resisting load and may be at risk for loosening. There is a need for more objective intra-operative techniques to test cup stability. © 2014.

  4. Origins of Negative Strain Rate Dependence of Stress Corrosion Cracking Initiation in Alloy 690, and Intergranular Crack Formation in Thermally Treated Alloy 690

    NASA Astrophysics Data System (ADS)

    Kim, Young Suk; Kim, Sung Soo

    2016-09-01

    We show that enhanced stress corrosion cracking (SCC) initiation in cold-rolled Alloy 690 with decreasing strain rate is related to the rate of short-range ordering (SRO) but not to the time-dependent corrosion process. Evidence for SRO is provided by aging tests on cold-rolled Alloy 690 at 623 K and 693 K (350 °C and 420 °C), respectively, which demonstrate its enhanced lattice contraction and hardness increase with aging temperature and time, respectively. Secondary intergranular cracks formed only in thermally treated and cold-rolled Alloy 690 during SCC tests, which are not SCC cracks, are caused by its lattice contraction by SRO before SCC tests but not by the orientation effect.

  5. Evaluation of the ARDESOS Program: An Initiative to Improve Critical Thinking Skills

    ERIC Educational Resources Information Center

    Saiz, Carlos; Rivas, Silvia F.

    2011-01-01

    It is desirable that reasoning, problem-solving and decision-making skills should form an integral part of our private and professional lives. Here we show how these skills can be improved through the use of the ARDESOS program. To test the effect of the program, we have also developed an assessment test (PENCRISAL). Our results are going in the…

  6. Immediate effect of couple relationship education on low-satisfaction couples: a randomized clinical trial plus an uncontrolled trial replication.

    PubMed

    Kim Halford, W; Pepping, Christopher A; Hilpert, Peter; Bodenmann, Guy; Wilson, Keithia L; Busby, Dean; Larson, Jeffry; Holman, Thomas

    2015-05-01

    Couple relationship education (RE) usually is conceived of as relationship enhancement for currently satisfied couples, with a goal of helping couples sustain satisfaction. However, RE also might be useful as a brief, accessible intervention for couples with low satisfaction. Two studies were conducted that tested whether couples with low relationship satisfaction show meaningful gains after RE. Study 1 was a three-condition randomized controlled trial in which 182 couples were randomly assigned to RELATE with Couple CARE (RCC), a flexible delivery education program for couples, or one of two control conditions. Couples with initially low satisfaction receiving RCC showed a moderate increase in relationship satisfaction (d=0.50) relative to the control. In contrast, couples initially high in satisfaction showed little change and there was no difference between RCC and the control conditions. Study 2 was an uncontrolled trial of the Couple Coping Enhancement Training (CCET) administered to 119 couples. Couples receiving CCET that had initially low satisfaction showed a moderate increase in satisfaction (g=.44), whereas initially highly satisfied couples showed no change. Brief relationship education can assist somewhat distressed couples to enhance satisfaction, and has potential as a cost-effective way of enhancing the reach of couple interventions. Copyright © 2015. Published by Elsevier Ltd.

  7. A follow-on study for miniature solid-state pressure transducer

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The activities of a developmental program to design, fabricate and test an absolute pressure transducer based upon the piezojunction properties of silicon are summarized. The prime problem addressed is the development of a housing capable of applying the high stress levels needed for sensitive piezojunction operation but at the same, free from the creep effects and the fragility that limit the usefulness of previous designs. The first part of the report describes the initial fabrication and test and reviews the theory of sensor performance. The second part incorporates two recommendations of the first part (the use of commercially manufactured silicon planar mesa diodes and the adoption of an all-silicon structure for loading) and presents some preliminary test data on the transducers thus fabricated. These initial measurements show much improved performance over any previously fabricated piezojunction transducers but testing is incomplete and several problems in manufacturing technology remain.

  8. The design organization test: further demonstration of reliability and validity as a brief measure of visuospatial ability.

    PubMed

    Killgore, William D S; Gogel, Hannah

    2014-01-01

    Neuropsychological assessments are frequently time-consuming and fatiguing for patients. Brief screening evaluations may reduce test duration and allow more efficient use of time by permitting greater attention toward neuropsychological domains showing probable deficits. The Design Organization Test (DOT) was initially developed as a 2-min paper-and-pencil alternative for the Block Design (BD) subtest of the Wechsler scales. Although initially validated for clinical neurologic patients, we sought to further establish the reliability and validity of this test in a healthy, more diverse population. Two alternate versions of the DOT and the Wechsler Abbreviated Scale of Intelligence (WASI) were administered to 61 healthy adult participants. The DOT showed high alternate forms reliability (r = .90-.92), and the two versions yielded equivalent levels of performance. The DOT was highly correlated with BD (r = .76-.79) and was significantly correlated with all subscales of the WASI. The DOT proved useful when used in lieu of BD in the calculation of WASI IQ scores. Findings support the reliability and validity of the DOT as a measure of visuospatial ability and suggest its potential worth as an efficient estimate of intellectual functioning in situations where lengthier tests may be inappropriate or unfeasible.

  9. Testing and modeling of PBX-9591 shock initiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lam, Kim; Foley, Timothy; Novak, Alan

    2010-01-01

    This paper describes an ongoing effort to develop a detonation sensitivity test for PBX-9501 that is suitable for studying pristine and damaged HE. The approach involves testing and comparing the sensitivities of HE pressed to various densities and those of pre-damaged samples with similar porosities. The ultimate objectives are to understand the response of pre-damaged HE to shock impacts and to develop practical computational models for use in system analysis codes for HE safety studies. Computer simulation with the CTH shock physics code is used to aid the experimental design and analyze the test results. In the calculations, initiation andmore » growth or failure of detonation are modeled with the empirical HVRB model. The historical LANL SSGT and LSGT were reviewed and it was determined that a new, modified gap test be developed to satisfy the current requirements. In the new test, the donor/spacer/acceptor assembly is placed in a holder that is designed to work with fixtures for pre-damaging the acceptor sample. CTH simulations were made of the gap test with PBX-9501 samples pressed to three different densities. The calculated sensitivities were validated by test observations. The agreement between the computed and experimental critical gap thicknesses, ranging from 9 to 21 mm under various test conditions, is well within 1 mm. These results show that the numerical modeling is a valuable complement to the experimental efforts in studying and understanding shock initiation of PBX-9501.« less

  10. Heart failure diagnosis in acute conditions has high agreement with inpatient diagnosis.

    PubMed

    Seronde, Marie-France; Laribi, Said; Collins, Sean P; Deye, Nicolas; Logeart, Damien; Plaisance, Patrick; Cohen-Solal, Alain; Mebazaa, Alexandre

    2016-06-01

    Acute heart failure (AHF) is frequently encountered in the emergency department (ED) or in the cardiac care unit (CCU)/ICU. Discrimination between cardiac and noncardiac cause of dyspnea by clinical means and standard testing is sometimes inadequate. The aim of our study was to assess AHF diagnosis agreement as determined by: (a) the attending physician, (b) the hospital discharge diagnosis, and (c) an adjudication committee. Between 2010 and 2011, consecutive patients arriving for dyspnea in our hospital were prospectively included. A convenience sample of patients was enrolled in this analysis. Patients were admitted through the ED (280 patients) or through CCU/ICU (112 patients) for undifferentiated dyspnea. Overall, few differences were observed between the initial diagnosis and the hospital discharge diagnosis or the adjudicated diagnosis. Among the 200 patients with an initial diagnosis of AHF, hospital discharge diagnosis confirmed AHF (alone or combined) in 191 (95.5%) patients and the adjudication committee confirmed AHF (alone or combined) in 196 (98%) patients. Our study showed considerable agreement between different AHF diagnostic standards. An initial AHF diagnosis on the basis of clinical signs and biological parameters utilizing B-type natriuretic peptide testing has high agreement and accuracy with the hospital discharge and adjudicated diagnosis of AHF. The present study also shows that the accuracy of the initial AHF diagnosis allows rapid inclusion in AHF trials. These results, if confirmed in a broader cohort of patients, suggest that the initial ED diagnosis is highly accurate and reliable to guide further inpatient management.

  11. 10 CFR 26.139 - Reporting initial validity and drug test results.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Reporting initial validity and drug test results. 26.139... § 26.139 Reporting initial validity and drug test results. (a) The licensee testing facility shall... permitted under § 26.75(h), positive test results from initial drug tests at the licensee testing facility...

  12. 10 CFR 26.139 - Reporting initial validity and drug test results.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Reporting initial validity and drug test results. 26.139... § 26.139 Reporting initial validity and drug test results. (a) The licensee testing facility shall... permitted under § 26.75(h), positive test results from initial drug tests at the licensee testing facility...

  13. Controlled ultrasound tissue erosion: The role of dynamic interaction between insonation and microbubble activity

    PubMed Central

    Xu, Zhen; Fowlkes, J. Brian; Rothman, Edward D.; Levin, Albert M.; Cain, Charles A.

    2009-01-01

    Previous studies showed that ultrasound can mechanically remove tissue in a localized, controlled manner. Moreover, enhanced acoustic backscatter is highly correlated with the erosion process. “Initiation” and “extinction” of this highly backscattering environment were studied in this paper. The relationship between initiation and erosion, variability of initiation and extinction, and effects of pulse intensity and gas saturation on time to initiation (initiation delay time) were investigated. A 788-kHz single-element transducer was used. Multiple pulses at a 3-cycle pulse duration and a 20-kHz pulse repetition frequency were applied. ISPPA values between 1000 and 9000 W/cm2 and gas saturation ranges of 24%–28%, 39%–49%, and 77%–81% were tested. Results show the following: (1) without initiation, erosion was never observed; (2) initiation and extinction of the highly backscattering environment were stochastic in nature and dependent on acoustic parameters; (3) initiation delay times were shorter with higher intensity and higher gas saturation (e.g., the mean initiation delay time was 66.9 s at ISPPA of 4000 W/cm2 and 3.6 ms at ISPPA of 9000 W/cm2); and (4) once initiated by high-intensity pulses, the highly backscattering environment and erosion can be sustained using a significantly lower intensity than that required to initiate the process. PMID:15704435

  14. Getting better, but not well: A 1.5 year follow-up of cognitive performance and cortisol levels in clinical and non-Clinical burnout.

    PubMed

    Oosterholt, Bart G; Maes, Joseph H R; Van der Linden, Dimitri; Verbraak, Marc J P M; Kompier, Michiel A J

    2016-05-01

    The purpose was to reexamine cognitive performance and cortisol levels of initial clinical burnout patients, non-clinical burnout individuals, and healthy controls. After 1.5-years of the initial measurement, clinical burnout patients showed a reduction of burnout symptoms and general physical and psychological complaints, but these were still elevated compared with controls. Nonetheless, they continued to report cognitive problems and still showed a minor impaired cognitive test performance. However, they no longer reported larger subjective costs associated with cognitive test performance and their cortisol awakening response (CAR) returned to a normal level. Compared with controls, non-clinical burnout individuals still reported the same, elevated, level of burnout symptoms, general physical and psychological complaints, and cognitive problems. Their cognitive test performance and associated subjective costs remained normal. However, they seemed to continue to display a lowered CAR. To conclude, after 1.5-years, clinical burnout patients got better, but not 'well', and non-clinical burnout individuals remained not 'well'. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Daphnia magna shows reduced infection upon secondary exposure to a pathogen

    PubMed Central

    McTaggart, Seanna J.; Wilson, Philip J.; Little, Tom J.

    2012-01-01

    Previous pathogen exposure is an important predictor of the probability of becoming infected. This is deeply understood for vertebrate hosts, and increasingly so for invertebrate hosts. Here, we test if an initial pathogen exposure changes the infection outcome to a secondary pathogen exposure in the natural host–pathogen system Daphnia magna and Pasteuria ramosa. Hosts were initially exposed to an infective pathogen strain, a non-infective pathogen strain or a control. The same hosts underwent a second exposure, this time to an infective pathogen strain, either immediately after the initial encounter or 48 h later. We observed that an initial encounter with a pathogen always conferred protection against infection compared with controls. PMID:22875818

  16. Daphnia magna shows reduced infection upon secondary exposure to a pathogen.

    PubMed

    McTaggart, Seanna J; Wilson, Philip J; Little, Tom J

    2012-12-23

    Previous pathogen exposure is an important predictor of the probability of becoming infected. This is deeply understood for vertebrate hosts, and increasingly so for invertebrate hosts. Here, we test if an initial pathogen exposure changes the infection outcome to a secondary pathogen exposure in the natural host-pathogen system Daphnia magna and Pasteuria ramosa. Hosts were initially exposed to an infective pathogen strain, a non-infective pathogen strain or a control. The same hosts underwent a second exposure, this time to an infective pathogen strain, either immediately after the initial encounter or 48 h later. We observed that an initial encounter with a pathogen always conferred protection against infection compared with controls.

  17. The influence of cutting speed and cutting initiation location in specimen preparation for the microtensile bond strength test.

    PubMed

    Abreu, Celina Wanderley; Santosb, Jarbas F; Passos, Sheila Pestana; Michida, Silvia Masae; Takahashi, Fernando Eidi; Bottino, Marco Antonio

    2011-06-01

    This study evaluated the effect of cutting initiation location and cutting speed on the bond strength between resin cement and feldspathic ceramic. Thirty-six blocks (6.4 x 6.4 x 4.8 mm) of ceramic (Vita VM7) were produced. The ceramic surfaces were etched with 10% hydrofluoric acid gel for 60 s and then silanized. Each ceramic block was placed in a silicon mold with the treated surface exposed. A resin cement (Variolink II) was injected into the mold over the treated surface and polymerized. The resin cement-ceramic blocks were divided into two groups according to experimental conditions: a) cutting initiation location - resin cement, ceramic and interface; and b) cutting speed - 10,000, 15,000, and 20,000 rpm. The specimens were sectioned to achieve non-trimmed bar specimens. The microtensile test was performed in a universal testing machine (1 mm/min). The failure modes were examined using an optical light microscope and SEM. Bond strength results were analyzed using one-way ANOVA and Tukey's test (α = 0.05). Significant influences of cutting speed and initiation location on bond strength (p < 0.05) were observed. The highest mean was achieved for specimens cut at 15,000 rpm at the interface (15.12 ± 5.36 MPa). The lowest means were obtained for specimens cut at the highest cutting speed in resin cement (8.50 ± 3.27 MPa), and cut at the lowest cutting speed in ceramic (8.60 ± 2.65 MPa). All groups showed mainly mixed failure (75% to 100%). The cutting speed and initiation location are important factors that should be considered during specimen preparation for microtensile bond strength testing, as both may influence the bond strength results.

  18. Two-IMU FDI performance of the sequential probability ratio test during shuttle entry

    NASA Technical Reports Server (NTRS)

    Rich, T. M.

    1976-01-01

    Performance data for the sequential probability ratio test (SPRT) during shuttle entry are presented. Current modeling constants and failure thresholds are included for the full mission 3B from entry through landing trajectory. Minimum 100 percent detection/isolation failure levels and a discussion of the effects of failure direction are presented. Finally, a limited comparison of failures introduced at trajectory initiation shows that the SPRT algorithm performs slightly worse than the data tracking test.

  19. Acute-Onset Panhypopituitarism Nearly Missed by Initial Cosyntropin Testing.

    PubMed

    Blum, Claudine A; Schneeberger, Daniel; Lang, Matthias; Rakic, Janko; Michot, Marc Philippe; Müller, Beat

    2017-01-01

    Diagnosis of adrenal crisis and panhypopituitarism in patients with septic shock is difficult but crucial for outcome. A 66-year-old woman with metastasized breast cancer presented to the ED with respiratory insufficiency and septic shock after a 2-day history of the flu. After transfer to the ICU, corticosteroids were started in addition to antibiotics, as the patient was vasopressor-nonresponsive. Diabetes insipidus was diagnosed due to polyuria and treated with 4 mg desmopressin. Thereafter, norepinephrine could be tapered rapidly. On day 2, basal cortisol was 136 nmol/L with an increase to 579 nmol/L in low-dose cosyntropin testing. Polyuria had not developed again. Therefore, corticosteroids were stopped. On day 3, the patient developed again nausea, vomiting, and polyuria. Adrenal crisis and diabetes insipidus were postulated. Corticosteroids and desmopressin were restarted. Further testing confirmed panhypopituitarism. MRI showed a new sellar metastasis. After 2 weeks, stimulated cortisol in cosyntropin testing reached only 219 nmol/l, confirming adrenal insufficiency. The time course showed that the adrenal glands took 2 weeks to atrophy after loss of pituitary ACTH secretion. Therefore, a misleading result of the cosyntropin test in the initial phase with low basal cortisol and allegedly normal response to exogenous ACTH may be seen. Cosyntropin testing in the critically ill should be interpreted with caution and in the corresponding clinical setting.

  20. Effect of area ratio on the performance of a 5.5:1 pressure ratio centrifugal impeller

    NASA Technical Reports Server (NTRS)

    Schumann, L. F.; Clark, D. A.; Wood, J. R.

    1986-01-01

    A centrifugal impeller which was initially designed for a pressure ratio of approximately 5.5 and a mass flow rate of 0.959 kg/sec was tested with a vaneless diffuser for a range of design point impeller area ratios from 2.322 to 2.945. The impeller area ratio was changed by successively cutting back the impeller exit axial width from an initial value of 7.57 mm to a final value of 5.97 mm. In all, four separate area ratios were tested. For each area ratio a series of impeller exit axial clearances was also tested. Test results are based on impeller exit surveys of total pressure, total temperature, and flow angle at a radius 1.115 times the impeller exit radius. Results of the tests at design speed, peak efficiency, and an exit tip clearance of 8 percent of exit blade height show that the impeller equivalent pressure recovery coefficient peaked at a design point area ratio of approximately 2.748 while the impeller aerodynamic efficiency peaked at a lower value of area ratio of approximately 2.55. The variation of impeller efficiency with clearance showed expected trends with a loss of approximately 0.4 points in impeller efficiency for each percent increase in exit axial tip clearance for all impellers tested.

  1. Assessment of Bleeding and Thrombosis Based on Aspirin Responsiveness after Continuous-Flow Left Ventricular Assist Device Placement.

    PubMed

    Floroff, Catherine K; Rieger, Krista L; Veasey, Tara M; Strout, Sara E; DeNino, Walter F; Meadows, Holly B; Stroud, Martha R; Toole, John M; Heyward, Dawn P; Brisco-Bacik, Meredith A; Cook, Jennifer L; Lazarchick, John; Uber, Walter E

    Pump thrombosis (PT) is a severe complication of left ventricular assist device (LVAD) support. This study evaluated PT and bleeding after LVAD placement in patients responsive to a standard aspirin dose of 81 mg using platelet inhibition monitoring compared with initial nonresponders who were then titrated upward to achieve therapeutic response. Patients ≥ 18 years of age with initial placement of HeartMate II LVAD at our institution and at least one VerifyNow Aspirin test performed during initial hospitalization were included. The primary endpoints were bleeding and PT compared between initial aspirin responders and nonresponders. Of 85 patients, 19 (22%) were nonresponsive to initial aspirin therapy. Responders and nonresponders showed similar survival (p = 0.082), freedom from suspected/confirmed PT (p = 0.941), confirmed PT (p = 0.273), bleeding (p = 0.401), and incidence rates in PT and bleeding. Among the initial responders (<500 vs. 500-549 aspirin reaction units), there were no significant differences in survival (p = 0.177), freedom from suspected/confirmed PT (p = 0.542), confirmed PT (p = 0.159), bleeding (p = 0.879), and incidence of PT and bleeding. Platelet function testing may detect resistance to standard aspirin regimens used in LVAD patients. Dose escalation in initially nonresponsive patients to achieve responsiveness may confer a similar PT risk to patients initially responsive to standard aspirin dosing without increased bleeding risk.

  2. Heavy-section steel irradiation program. Progress report, April 1996--September 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corwin, W.R.

    1997-09-01

    The Heavy-Section Steel Irradiation Program was established to quantitatively assess the effects of neutron irradiation on the material behavior of typical reactor pressure vessel (RPV) steels. During this period, fracture mechanics testing of specimens of the irradiated low upper shelf (LUS) weld were completed and analyses performed. Heat treatment of five RPV plate materials was initiated to examine phosphorus segregation effects on the fracture toughness of the heat affected zone of welds. Initial results show that all five materials exhibited very large prior austenite grain sizes as a consequence of the initial heat treatment. Irradiated and annealed specimens of LUSmore » weld material were tested and analyzed. Four sets of Charpy V-notch (CVN) specimens were aged at various temperatures and tested to examine the reason for overrecovery of upper shelf energy that has been observed. Molecular dynamics cascade simulations were extended to 40 keV and have provided information representative of most of the fast neutron spectrum. Investigations of the correlation between microstructural changes and hardness changes in irradiated model alloys was also completed. Preliminary planning for test specimen machining for the Japan Power Development Reactor was completed. A database of Charpy impact and fracture toughness data for RPV materials that have been tested in the unirradiated and irradiated conditions is being assembled and analyzed. Weld metal appears to have similar CVN and fracture toughness transition temperature shifts, whereas the fracture toughness shifts are greater than CVN shifts for base metals. Draft subcontractor reports on precracked cylindrical tensile specimens were completed, reviewed, and are being revised. Testing on precracked CVN specimens, both quasi-static and dynamic, was evaluated. Additionally, testing of compact specimens was initiated as an experimental comparison of constraint limitations. 16 figs., 2 tabs.« less

  3. Development and Validation of a New Questionnaire Assessing Quality of Life in Adults with Hypopituitarism: Adult Hypopituitarism Questionnaire (AHQ)

    PubMed Central

    Ishii, Hitoshi; Shimatsu, Akira; Okimura, Yasuhiko; Tanaka, Toshiaki; Hizuka, Naomi; Kaji, Hidesuke; Hanew, Kunihiko; Oki, Yutaka; Yamashiro, Sayuri; Takano, Koji; Chihara, Kazuo

    2012-01-01

    Objective To develop and validate the Adult Hypopituitarism Questionnaire (AHQ) as a disease-specific, self-administered questionnaire for evaluation of quality of life (QOL) in adult patients with hypopituitarism. Methods We developed and validated this new questionnaire, using a standardized procedure which included item development, pilot-testing and psychometric validation. Of the patients who participated in psychometric validation, those whose clinical conditions were judged to be stable were asked to answer the survey questionnaire twice, in order to assess test-retest reliability. Results Content validity of the initial questionnaire was evaluated via two pilot tests. After these tests, we made minor revisions and finalized the initial version of the questionnaire. The questionnaire was constructed with two domains, one psycho-social and the other physical. For psychometric assessment, analyses were performed on the responses of 192 adult patients with various types of hypopituitarism. The intraclass correlations of the respective domains were 0.91 and 0.95, and the Cronbach’s alpha coefficients were 0.96 and 0.95, indicating adequate test-retest reliability and internal consistency for each domain. For known-group validity, patients with hypopituitarism due to hypothalamic disorder showed significantly lower scores in 11 out of 13 sub-domains compared to those who had hypopituitarism due to pituitary disorder. Regarding construct validity, the domain structure was found to be almost the same as that initially hypothesized. Exploratory factor analysis (n = 228) demonstrated that each domain consisted of six and seven sub-domains. Conclusion The AHQ showed good reliability and validity for evaluating QOL in adult patients with hypopituitarism. PMID:22984490

  4. Neural correlates of retrieval-based memory enhancement: An fMRI study of the testing effect

    PubMed Central

    Wing, Erik A.; Marsh, Elizabeth J.; Cabeza, Roberto

    2013-01-01

    Restudying material is a common method for learning new information, but not necessarily an effective one. Research on the testing effect shows that practice involving retrieval from memory can facilitate later memory in contrast to passive restudy. Despite extensive behavioral work, the brain processes that make retrieval an effective learning strategy remain unclear. In the present experiment, we explored how initially retrieving items affected memory a day later as compared to a condition involving traditional restudy. In contrast to restudy, initial testing that contributed to future memory success was associated with engagement of several regions including the anterior hippocampus, lateral temporal cortices, and medial prefrontal cortex (PFC). Additionally, testing enhanced hippocampal connectivity with ventrolateral PFC and midline regions. These findings indicate that the testing effect may be contingent on processes that are typically thought to support memory success at encoding (e.g. relational binding, selection and elaboration of semantically-related information) in addition to those more often associated with retrieval (e.g. memory search). PMID:23607935

  5. Experimental and numerical investigations on freeze-drying of porous media with prebuilt porosity

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Yang, Jing; Hu, Dapeng; Pan, Yanqiu; Wang, Shihao; Chen, Guohua

    2018-05-01

    Freeze-drying of initially porous frozen material was investigated aimed at improving the process economics by reducing drying time and raising productivity. Experimental results showed that freeze-drying can be significantly enhanced by the frozen material with prebuilt porosity, and about 31% of drying time can be saved compared with the conventionally solid frozen material under the tested operating conditions. A multiphase transport model was formulated based on the local mass non-equilibrium assumption. Numerical results showed excellent agreements between measured and predicted drying curves. Analyses of saturation and temperature profiles displayed that volumetric sublimation-desorption can occur for the initially porous frozen material.

  6. The effects of initial testing on false recall and false recognition in the social contagion of memory paradigm.

    PubMed

    Huff, Mark J; Davis, Sara D; Meade, Michelle L

    2013-08-01

    In three experiments, participants studied photographs of common household scenes. Following study, participants completed a category-cued recall test without feedback (Exps. 1 and 3), a category-cued recall test with feedback (Exp. 2), or a filler task (no-test condition). Participants then viewed recall tests from fictitious previous participants that contained erroneous items presented either one or four times, and then completed final recall and source recognition tests. The participants in all conditions reported incorrect items during final testing (a social contagion effect), and across experiments, initial testing had no impact on false recall of erroneous items. However, on the final source-monitoring recognition test, initial testing had a protective effect against false source recognition: Participants who were initially tested with and without feedback on category-cued initial tests attributed fewer incorrect items to the original event on the final source-monitoring recognition test than did participants who were not initially tested. These data demonstrate that initial testing may protect individuals' memories from erroneous suggestions.

  7. Dynamic Fracture Initiation Toughness at Elevated Temperatures With Application to the New Generation of Titanium Aluminide Alloys. Chapter 8

    NASA Technical Reports Server (NTRS)

    Shazly, Mostafa; Prakash, Vikas; Draper, Susan; Shukla, Arun (Editor)

    2006-01-01

    Recently, a new generation of titanium aluminide alloy, named Gamma-Met PX, has been developed with better rolling and post-rolling characteristics. I'revious work on this alloy has shown the material to have higher strengths at room and elevated temperatures when compared with other gamma titanium aluminides. In particular, this new alloy has shown increased ductility at elevated temperatures under both quasi-static and high strain rate uniaxial compressive loading. However, its high strain rate tensile ductility at room and elevated temperatures is limited to approx. 1%. In the present chapter, results of a study to investigate the effects of loading rate and test temperature on the dynamic fracture initiation toughness in Gamma-Met PX are presented. Modified split Hopkinson pressure bar was used along with high-speed photography to determine the crack initiation time. Three-point bend dynamic fracture experiments were conducted at impact speeds of approx. 1 m/s and tests temperatures of up-to 1200 C. The results show that thc dynamic fracture initiation toughness decreases with increasing test temperatures beyond 600 C. Furthermore, thc effect of long time high temperature air exposure on the fracture toughness was investigated. The dynamic fracture initiation toughness was found to decrease with increasing exposure time. The reasons behind this drop are analyzed and discussed.

  8. 46 CFR 56.97-38 - Initial service leak test (reproduces 137.7).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Initial service leak test (reproduces 137.7). 56.97-38... PIPING SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-38 Initial service leak test (reproduces 137.7). (a) An initial service leak test and inspection is acceptable when other types of test are not...

  9. The Role of Covert Retrieval in Working Memory Span Tasks: Evidence from Delayed Recall Tests

    ERIC Educational Resources Information Center

    McCabe, David P.

    2008-01-01

    The current study examined delayed recall of items that had been processed during simple and complex span tasks. Three experiments were reported showing that despite more items being recalled initially from a simple span task (i.e., word span) than a complex span task (i.e., operation span), on a delayed recall test more items were recalled that…

  10. I've Fallen and I Can't Get up: Can High-Ability Students Recover from Early Mistakes in CAT?

    ERIC Educational Resources Information Center

    Rulison, Kelly L.; Loken, Eric

    2009-01-01

    A difficult result to interpret in Computerized Adaptive Tests (CATs) occurs when an ability estimate initially drops and then ascends continuously until the test ends, suggesting that the true ability may be higher than implied by the final estimate. This study explains why this asymmetry occurs and shows that early mistakes by high-ability…

  11. Test Score Gaps between Private and Government Sector Students at School Entry Age in India

    ERIC Educational Resources Information Center

    Singh, Abhijeet

    2014-01-01

    Various studies have noted that students enrolled in private schools in India perform better on average than students in government schools. In this paper, I show that large gaps in the test scores of children in private and public sector education are evident even at the point of initial enrollment in formal schooling and are associated with…

  12. Components of visual search in childhood-onset schizophrenia and attention-deficit/hyperactivity disorder.

    PubMed

    Karatekin, C; Asarnow, R F

    1998-10-01

    This study tested the hypotheses that visual search impairments in schizophrenia are due to a delay in initiation of search or a slow rate of serial search. We determined the specificity of these impairments by comparing children with schizophrenia to children with attention-deficit hyperactivity disorder (ADHD) and age-matched normal children. The hypotheses were tested within the framework of feature integration theory by administering children tasks tapping parallel and serial search. Search rate was estimated from the slope of the search functions, and duration of the initial stages of search from time to make the first saccade on each trial. As expected, manual response times were elevated in both clinical groups. Contrary to expectation, ADHD, but not schizophrenic, children were delayed in initiation of serial search. Finally, both groups showed a clear dissociation between intact parallel search rates and slowed serial search rates.

  13. A Self-Alignment Algorithm for SINS Based on Gravitational Apparent Motion and Sensor Data Denoising

    PubMed Central

    Liu, Yiting; Xu, Xiaosu; Liu, Xixiang; Yao, Yiqing; Wu, Liang; Sun, Jin

    2015-01-01

    Initial alignment is always a key topic and difficult to achieve in an inertial navigation system (INS). In this paper a novel self-initial alignment algorithm is proposed using gravitational apparent motion vectors at three different moments and vector-operation. Simulation and analysis showed that this method easily suffers from the random noise contained in accelerometer measurements which are used to construct apparent motion directly. Aiming to resolve this problem, an online sensor data denoising method based on a Kalman filter is proposed and a novel reconstruction method for apparent motion is designed to avoid the collinearity among vectors participating in the alignment solution. Simulation, turntable tests and vehicle tests indicate that the proposed alignment algorithm can fulfill initial alignment of strapdown INS (SINS) under both static and swinging conditions. The accuracy can either reach or approach the theoretical values determined by sensor precision under static or swinging conditions. PMID:25923932

  14. Same day ART initiation versus clinic-based pre-ART assessment and counselling for individuals newly tested HIV-positive during community-based HIV testing in rural Lesotho - a randomized controlled trial (CASCADE trial).

    PubMed

    Labhardt, Niklaus Daniel; Ringera, Isaac; Lejone, Thabo Ishmael; Masethothi, Phofu; Thaanyane, T'sepang; Kamele, Mashaete; Gupta, Ravi Shankar; Thin, Kyaw; Cerutti, Bernard; Klimkait, Thomas; Fritz, Christiane; Glass, Tracy Renée

    2016-04-14

    Achievement of the UNAIDS 90-90-90 targets in Sub-Sahara Africa is challenged by a weak care-cascade with poor linkage to care and retention in care. Community-based HIV testing and counselling (HTC) is widely used in African countries. However, rates of linkage to care and initiation of antiretroviral therapy (ART) in individuals who tested HIV-positive are often very low. A frequently cited reason for non-linkage to care is the time-consuming pre-ART assessment often requiring several clinic visits before ART-initiation. This two-armed open-label randomized controlled trial compares in individuals tested HIV-positive during community-based HTC the proposition of same-day community-based ART-initiation to the standard of care pre-ART assessment at the clinic. Home-based HTC campaigns will be conducted in catchment areas of six clinics in rural Lesotho. Households where at least one individual tested HIV positive will be randomized. In the standard of care group individuals receive post-test counselling and referral to the nearest clinic for pre-ART assessment and counselling. Once they have started ART the follow-up schedule foresees monthly clinic visits. Individuals randomized to the intervention group receive on the spot point-of-care pre-ART assessment and adherence counselling with the proposition to start ART that same day. Once they have started ART, follow-up clinic visits will be less frequent. First primary outcome is linkage to care (individual presents at the clinic at least once within 3 months after the HIV test). The second primary outcome is viral suppression 12 months after enrolment in the study. We plan to enrol a minimum of 260 households with 1:1 allocation and parallel assignment into both arms. This trial will show if in individuals tested HIV-positive during community-based HTC campaigns the proposition of same-day ART initiation in the community, combined with less frequent follow-up visits at the clinic could be a pragmatic approach to improve the care cascade in similar settings. NCT02692027 , registered February 21, 2016.

  15. Influence of Self-generated Anchors on the Voice Handicap Index-10 (VHI-10).

    PubMed

    Canals-Fortuny, Elisabet; Vila-Rovira, Josep

    2017-03-01

    The aim of this research is to study whether the presentation of the Voice Handicap Index-10 questionnaire administered at the beginning of the treatment impinged on the results of the responses from the end of the treatment. The questionnaire was administered at the beginning of the treatment to a total of 308 patients. After the treatment, a group of 235 patients answered the questionnaire again without any reference to their responses on the initial administration. The other group of participants, consisting of 73 subjects, completed the questionnaire with the answer sheet of their initial self-assessment in sight. The data obtained show that patients who responded to the anchored answer test show less dispersion and a smaller coefficient of variation (0.90) than those who responded to the nonanchored answer test (coefficient of variation = 1.66). The method of administration of the Voice Handicap Index-10 at the end of a treatment influences the dispersion of the results. We recommend that the patient be anchored to the initial answer sheet while responding to the final self-assessment. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  16. Initial conditions for cosmological N-body simulations of the scalar sector of theories of Newtonian, Relativistic and Modified Gravity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valkenburg, Wessel; Hu, Bin, E-mail: valkenburg@lorentz.leidenuniv.nl, E-mail: hu@lorentz.leidenuniv.nl

    2015-09-01

    We present a description for setting initial particle displacements and field values for simulations of arbitrary metric theories of gravity, for perfect and imperfect fluids with arbitrary characteristics. We extend the Zel'dovich Approximation to nontrivial theories of gravity, and show how scale dependence implies curved particle paths, even in the entirely linear regime of perturbations. For a viable choice of Effective Field Theory of Modified Gravity, initial conditions set at high redshifts are affected at the level of up to 5% at Mpc scales, which exemplifies the importance of going beyond Λ-Cold Dark Matter initial conditions for modifications of gravitymore » outside of the quasi-static approximation. In addition, we show initial conditions for a simulation where a scalar modification of gravity is modelled in a Lagrangian particle-like description. Our description paves the way for simulations and mock galaxy catalogs under theories of gravity beyond the standard model, crucial for progress towards precision tests of gravity and cosmology.« less

  17. A seven-year follow-up of intelligence test scores of foster grandparents.

    PubMed

    Troll, L E; Saltz, R; Dunin-Markiewicz, A

    1976-09-01

    After 7 years, a group of originally nonemployed poverty-level older people (over 60) who had been employed as foster grandparents were retested with the WAIS. Four WAIS subtests - Vocabulary Similarities, Digit Span, and Block Design - were employed. Of the original group of 39, complete data were available for 28; 18 of these were still working on the project, and the other 10 had dropped out. Dropouts as a group tested lower originally and also showed more deterioration in functional health ratings over time. For the total group of 32 foster grandparents, three subtest scores showed stability over the 7 years. Only Digit Span showed a statistically significant drop. Neither age nor the initial level of health or WAIS scores was related to test-score changes over time.

  18. Novel Processing of Boron Carbide (B4C): Plasma Synthesized Nano Powders and Pressureless Sintering Forming of Complex Shapes

    DTIC Science & Technology

    2008-12-01

    Figure 4. B4C plates formed via hot pressing with a curved shape. Commercial B4C shows a large number of lenticular graphitic inclusions, Figure 5...materials and they act as crack initiation points in flexure testing. Figure 5. SEM micrograph showing large lenticular graphitic inclusions in commercial

  19. [Normative prenatal evaluation at a philanthropic maternity hospital in São Paulo].

    PubMed

    Corrêa, Claudia Regina Hostim; Bonadio, Isabel Cristina; Tsunechiro, Maria Alice

    2011-12-01

    This cross-sectional study counted with the participation of 301 pregnant women seen in 2009 at a philanthropic maternity hospital in the city of São Paulo (a prenatal support program named Pré-Natal do Amparo Maternal - PN-AM). The objectives of this study were to evaluate the prenatal care according to the initial gestational age, the number of appointments that were held, the continuity of the assistance, and relate the appropriateness with the socio-demographic, obstetric and local variables of the initial prenatal care. The analysis criteria used was initiating prenatal care before 120 days of gestation and attending at least six appointments. The relationship between the variables was analyzed using the Chi-Square Test. Results showed that 41.5% of the pregnant women initiated prenatal care at another health care service and transferred spontaneously to the PN-AM; 74.1% initiated the prenatal care early and 80.4% attended at least six appointments; 63.1% met both criteria simultaneously. Appropriate prenatal care showed a statistically significant difference for mother's age, steady partner, employment, place of residence, having a companion during the appointment and place where prenatal care was initiated.

  20. Isothermal dendritic growth experiment: Science, engineering, and hardware development for USMP space flights

    NASA Astrophysics Data System (ADS)

    Glicksman, M. E.; Hahn, R. C.; Koss, M. B.; Tirmizi, S. H.; Selleck, M. E.; Velosa, A.; Winsa, E.

    The Isothermal Dendritic Growth Experiment (IDGE) has been designed to provide microgravity data on dendritic growth for a critical test of theory. This paper updates our progress on constructing a crystal growth chamber suitable for space flight. The IDGE chamber is constructed from glass and stainless steel and is hermetically sealed by electron beam welds and glass-metal seals. Initial tests of the chambers sample's melting point plateau show that the new chamber design is capable of preserving the 99.9995 pct purity of succinonitrile (SCN). One can initiate dendrite growth in the center of the IDGE chamber by means of thermo-electric coolers and a capillary injector tube (stinger). The new IDGE chamber is ready for fully integrated tests with the prototype IDGE engineering hardware at NASA's Lewis Research Center.

  1. What is an integrable quench?

    NASA Astrophysics Data System (ADS)

    Piroli, Lorenzo; Pozsgay, Balázs; Vernier, Eric

    2017-12-01

    Inspired by classical results in integrable boundary quantum field theory, we propose a definition of integrable initial states for quantum quenches in lattice models. They are defined as the states which are annihilated by all local conserved charges that are odd under space reflection. We show that this class includes the states which can be related to integrable boundary conditions in an appropriate rotated channel, in loose analogy with the picture in quantum field theory. Furthermore, we provide an efficient method to test integrability of given initial states. We revisit the recent literature of global quenches in several models and show that, in all of the cases where closed-form analytical results could be obtained, the initial state is integrable according to our definition. In the prototypical example of the XXZ spin-s chains we show that integrable states include two-site product states but also larger families of matrix product states with arbitrary bond dimension. We argue that our results could be practically useful for the study of quantum quenches in generic integrable models.

  2. Biotransformation of hexahydro-1,3,5-trinitro-1,3,5-tiazine catalyzed by a NAD(P)H: nitrate oxidoreductase from Aspergillus niger.

    PubMed

    Bhushan, Bharat; Halasz, Annamaria; Spain, Jim; Thiboutot, Sonia; Ampleman, Guy; Hawari, Jalal

    2002-07-15

    Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) can be efficiently mineralized with anaerobic domestic sludge, but the initial enzymatic processes involved in its transformation are unknown. To test the hypothesis that the initial reaction involves reduction of nitro group(s), we designed experiments to test the ability of a nitrate reductase (EC 1.6.6.2) to catalyze the initial reaction leading to ring cleavage and subsequent decomposition. A nitrate reductase from Aspergillus niger catalyzed the biotransformation of RDX most effectively at pH 7.0 and 30 degrees C under anaerobic conditions using NADPH as electron donor. LC/MS (ES-) chromatograms showed the formation of hexahydro-1-nitroso-3,5-dinitro-1,3,5-triazine (MNX) and methylenedinitramine as key initial products of RDX, but neither the dinitroso neither (DNX) nor trinitroso (TNX) derivatives were observed. None of the above detected products persisted, and their disappearance was accompanied by the accumulation of nitrous oxide (N20), formaldehyde (HCHO), and ammonium ion (NH4+). Stoichiometric studies showed that three NADPH molecules were consumed, and one molecule of methylenedinitramine was produced per RDX molecule. The carbon and nitrogen mass balances were 96.14% and 82.10%, respectively. The stoichiometries and mass balance measurements supported a mechanism involving initial transformation of RDX to MNX via a two-electron reduction mechanism. Subsequent reduction of MNX followed by rapid ring cleavage gave methylenedinitramine which in turn decomposed in water to produce quantitatively N2O and HCHO. The results clearly indicate that an initial reduction of a nitro group by nitrate reductase is sufficient for the decomposition of RDX.

  3. Determination of HART I Blade Structural Properties by Laboratory Testing

    NASA Technical Reports Server (NTRS)

    Jung, Sung N.; Lau, Benton H.

    2012-01-01

    The structural properties of higher harmonic Aeroacoustic Rotor Test (HART I) blades were measured using the original set of blades tested in the German-dutch wind tunnel (DNW) in 1994. the measurements include bending and torsion stiffness, geometric offsets, and mass and inertia properties of the blade. the measured properties were compared to the estimated values obtained initially from the blade manufacturer. The previously estimated blade properties showed consistently higher stiffness, up to 30 percent for the flap bending in the blade inboard root section.

  4. Fluoride Availability and Stability in Children's Toothpastes in Uruguay.

    PubMed

    Loureiro, Licet Alvarez; Fager, Anunzziatta Fabruccini; Santos Moreira, Maurício José; Maltz, Marisa; Hashizume, Lina Naomi

    2017-05-15

    The purpose of this study was to evaluate the availability and stability of fluoride in children's toothpastes in Uruguay. Six commercial brands of children's toothpaste available in Uruguay were tested. Analyses were made when the dentifrices were purchased (fresh samples) and after one year of storage (aged samples). Total fluoride (TF) and total soluble fluoride (TSF) concentrations were determined using an ion specific electrode. Four of the children's dentifrices showed TF concentration similar to that specified on the package. Three products showed similar concentrations of TF and TSF with no variations after the one-year storage period. Two dentifrices showed an initial insoluble fluoride concentration greater than 50 percent, which increased with toothpaste aging. Most tested toothpastes showed a decrease in the soluble fluoride content with aging. The high quantity of insoluble fluoride found in two tested dentifrices may compromise their anti-caries efficacy.

  5. Honey bee foraging preferences, effects of sugars, and fruit fly toxic bait components.

    PubMed

    Mangan, Robert L; Moreno, Aleena Tarshis

    2009-08-01

    Field tests were carried out to evaluate the repellency of the Dow AgroSciences fruit fly toxic bait GF-120 (NF Naturalyte) to domestic honey bees (Apis mellifera L.). GF-120 is an organically registered attractive bait for tephritid fruit flies composed of spinosad, hydrolyzed protein (Solulys), high-fructose corn syrup (ADM CornSweet 42 high-fructose corn syrup, referred to as invertose sugar or invertose here), vegetable oils, adjuvants, humectants, and attractants. Tests were carried out with non-Africanized honey bees in February and March 2005 and 2007 during periods of maximum hunger for these bees. In all tests, bees were first trained to forage from plates of 30% honey-water (2005) or 30% invertose (2007). In 2005 bees were offered choices between honey-water and various bait components, including the complete toxic bait. In 2007, similar tests were performed except bees were attracted with 30% invertose then offered the bait components or complete bait as no-choice tests. Initially, the 2005 tests used all the components of GF-120 except the spinosad as the test bait. After we were convinced that bees would not collect or be contaminated by the bait, we tested the complete GF-120. Behavior of the bees indicated that during initial attraction and after switching the baits, the bait components and the complete bait were repellent to honey bees, but the honey-water remained attractive. Invertose was shown to be less attractive to bees, addition of Solulys eliminated almost all bee activity, and addition of ammonium acetate completely eliminated feeding in both choice and no-choice tests. These results confirm previous tests showing that bees do not feed on GF-120 and also show that honey bees are repelled by the fruit fly attractant components of the bait in field tests.

  6. Engineering sciences area and module performance and failure analysis area

    NASA Technical Reports Server (NTRS)

    Ross, R. G., Jr.; Runkle, L. D.

    1982-01-01

    Photovoltaic-array/power-conditioner interface studies are updated. An experiment conducted to evaluate different operating-point strategies, such as constant voltage and pilot cells, and to determine array energy losses when the array is operated off the maximum power points is described. Initial results over a test period of three and a half weeks showed a 2% energy loss when the array is operated at a fixed voltage. Degraded-array studies conducted at NE RES that used a range of simulated common types of degraded I-V curves are reviewed. The instrumentation installed at the JPL field-test site to obtain the irradiance data was described. Experiments using an optical filter to adjust the spectral irradiance of the large-area pulsed solar simulator (LAPSS) to AM1.5 are described. Residential-array research activity is reviewed. Voltage isolation test results are described. Experiments performed on one type of module to determine the relationship between leakage current and temperature are reviewed. An encapsulated-cell testing approach is explained. The test program, data reduction methods, and initial results of long-duration module testing are described.

  7. Development of Ground Test System For RKX-200EB

    NASA Astrophysics Data System (ADS)

    Yudhi Irwanto, Herma

    2018-04-01

    After being postponed for seven years, the development of RKX-200EB now restarts by initiating a ground test, preceding the real flight test. The series of the development starts from simulation test using the real vehicle and its components, focusing on a flight sequence test using hardware in the loop simulation. The result of the simulation shows that the autonomous control system in development is able to control the X tail fin vehicle, since take off using booster, separating booster-sustainer, making flight maneuver using sustainer with average cruise speed of 1000 km/h, and doing bank to maneuver up to ±40 deg heading to the target. The simulation result also shows that the presence of sustainer in vehicle control can expand the distance range by 162% (12.6 km) from its ballistic range using only a booster.

  8. Cyclic stress effect on stress corrosion cracking of duplex stainless steel in chloride and caustic solutions

    NASA Astrophysics Data System (ADS)

    Yang, Di

    Duplex stainless steel (DSS) is a dual-phase material with approximately equal volume amount of austenite and ferrite. It has both great mechanical properties (good ductility and high tensile/fatigue strength) and excellent corrosion resistance due to the mixture of the two phases. Cyclic loadings with high stress level and low frequency are experienced by many structures. However, the existing study on corrosion fatigue (CF) study of various metallic materials has mainly concentrated on relatively high frequency range. No systematic study has been done to understand the ultra-low frequency (˜10-5 Hz) cyclic loading effect on stress corrosion cracking (SCC) of DSSs. In this study, the ultra-low frequency cyclic loading effect on SCC of DSS 2205 was studied in acidified sodium chloride and caustic white liquor (WL) solutions. The research work focused on the environmental effect on SCC of DSS 2205, the cyclic stress effect on strain accumulation behavior of DSS 2205, and the combined environmental and cyclic stress effect on the stress corrosion crack initiation of DSS 2205 in the above environments. Potentiodynamic polarization tests were performed to investigate the electrochemical behavior of DSS 2205 in acidic NaCl solution. Series of slow strain rate tests (SSRTs) at different applied potential values were conducted to reveal the optimum applied potential value for SCC to happen. Room temperature static and cyclic creep tests were performed in air to illustrate the strain accumulation effect of cyclic stresses. Test results showed that cyclic loading could enhance strain accumulation in DSS 2205 compared to static loading. Moreover, the strain accumulation behavior of DSS 2205 was found to be controlled by the two phases of DSS 2205 with different crystal structures. The B.C.C. ferrite phase enhanced strain accumulation due to extensive cross-slips of the dislocations, whereas the F.C.C. austenite phase resisted strain accumulation due to cyclic strain hardening. Cyclic SSRTs were performed under the conditions that SCC occurs in sodium chloride and WL solutions. Test results show that cyclic stress facilitated crack initiations in DSS 2205. Stress corrosion cracks initiated from the intermetallic precipitates in acidic chloride environment, and the cracks initiated from austenite phase in WL environment. Cold-working has been found to retard the crack initiations induced by cyclic stresses.

  9. Neutron Imaging for Selective Laser Melting Inconel Hardware with Internal Passages

    NASA Technical Reports Server (NTRS)

    Tramel, Terri L.; Norwood, Joseph K.; Bilheux, Hassina

    2014-01-01

    Additive Manufacturing is showing great promise for the development of new innovative designs and large potential life cycle cost reduction for the Aerospace Industry. However, more development work is required to move this technology into space flight hardware production. With selective laser melting (SLM), hardware that once consisted of multiple, carefully machined and inspected pieces, joined together can be made in one part. However standard inspection techniques cannot be used to verify that the internal passages are within dimensional tolerances or surface finish requirements. NASA/MSFC traveled to Oak Ridge National Lab's (ORNL) Spallation Neutron Source to perform some non-destructive, proof of concept imaging measurements to assess the capabilities to understand internal dimensional tolerances and internal passages surface roughness. This presentation will describe 1) the goals of this proof of concept testing, 2) the lessons learned when designing and building these Inconel 718 test specimens to minimize beam time, 3) the neutron imaging test setup and test procedure to get the images, 4) the initial results in images, volume and a video, 4) the assessment of using this imaging technique to gather real data for designing internal flow passages in SLM manufacturing aerospace hardware, and lastly 5) how proper cleaning of the internal passages is critically important. In summary, the initial results are very promising and continued development of a technique to assist in SLM development for aerospace components is desired by both NASA and ORNL. A plan forward that benefits both ORNL and NASA will also be presented, based on the promising initial results. The initial images and volume reconstruction showed that clean, clear images of the internal passages geometry are obtainable. These clear images of the internal passages of simple geometries will be compared to the build model to determine any differences. One surprising result was that a new cleaning process was used on these simply geometric specimens that resulted in what appears to be very smooth internal surfaces, when compared to other aerospace hardware cleaning methods.

  10. [Audiological characteristics of young children with otitis media with effusion].

    PubMed

    Wang, Qiu-ju; Shi, Wei; Lan, Lan; Wang, Da-yong; Zhang, Ya-mei

    2008-12-01

    To characterize the audiological features in the infants with otitis media with effusion (OME) and to investigate the utility of variety of objective audiometry methods in diagnosis and intervention on OME. Fifty six infants (40 males and 16 females) were investigated, who were referred to our clinic at the General Hospital of Chinese People's Liberation Army by the other hospitals from December 2004 to June 2007 when the infants were diagnosed or highly suspected of OME. The ages at the initial diagnosis ranged from 42 days to three years, with an average of five months. The infants, after receiving the conventional otolaryngological exams, were subjected to the tests of auditory brainstem response (ABR), otoacoustic emission (OAE), tympanometry (226 Hz and 1000 Hz) and behaviors audiometry. Among 56 affected infants, 87 ears were diagnosed with OME, of which 31 infants were affected bilateral and 25 with monaural. For the 49 infants who received hearing screening at birth, 36 infants were referred at the initial screening. For the 52 infants who received repeated screening, all subjects were referred. Six infants without receiving hearing screening came to clinic when their parents observed their kids' hearing impairment. Among the 52 cases (104 ears) who received tympanometry test, 20 subjects (28 ears) showed B or C type tympanometry curve. Thirty-nine cases (78 ears) were given tympanometry test at 1000 Hz, of which 38 cases (55 ears) showed abnormal hearing. Among 56 infants (112 ears) with ABR test, 49 subjects (74 ears) exhibited prolonged ABR type I curve. All 56 infants (112 ears) received OAE test, of which 55 subjects (81 ears) were referred. Four infants (8 ears) accepted the behavior test and all of them showed A-B Gap. The combined tympanometry test at both 226 Hz and 1000 Hz, ABR latency or threshold test, infant's behavior test and OAE, used jointly, enable characterizing better OME in infants, thus helping early diagnosis of this hearing disorder.

  11. Effect of initial moisture content on performance of hardwood pallets.

    Treesearch

    Daniel E. Dunmire

    1966-01-01

    Four years of service testing 90 red oak pallets showed that those made with predrilled air-dry deckboards and green stringers gave better service and cost less to maintain than pallets made entirely from either green or air-dry lumber.

  12. Prognosis of adult-onset idiopathic bile acid malabsorption.

    PubMed

    Rössel, P; Sortsøe Jensen, H; Qvist, P; Arveschoug, A

    1999-06-01

    From 1986 to 1993, 150 patients were investigated with the 75Se-homocholic acid taurine (SeHCAT) test as a late step in the investigation of chronic diarrhoea. On basis of low SeHCAT values and response to cholestyramine treatment, 33 patients were initially classified as having idiopathic bile acid malabsorption (IBAM). The aim was to describe the long-term clinical course of the disease and to assess the reliability of the SeHCAT test in diagnosing IBAM. The methods included 1) clinical follow-up with patient interview combined with information from medical records and 2) repeated SeHCAT test. The diagnosis of IBAM had to be revised in three cases (inflammatory bowel disease in two patients, Clostridium difficile infection in one). Six patients were lost to follow-up and a further four patients were excluded from re-examination either because of old age (>80 years) or bowel resection, leaving 20 patients for re-examination, of which 16 completed both clinical follow-up and a new SeHCAT test. The median duration of symptoms before initial SeHCAT test was 2.5 (1-30) years. In 13 of 16 patients symptoms persisted, and SeHCAT values remained low and almost identical to the initial value after a median observation time of 88 (51-113) months. Despite initial response to treatment with cholestyramine, six patients had to discontinue treatment because of adverse effects or other compliance problems. In three patients the SeHCAT value showed a considerable increase, and bowel function had correspondingly normalized in these cases. The study confirms the reliability of the SeHCAT test in diagnosing IBAM. Despite adult onset of symptoms, only a few patients improve after several years' observation. Treatment with cholestyramine is generally effective but not always tolerated.

  13. Response to novelty as a predictor of cocaine sensitization and conditioning in rats: a correlational analysis.

    PubMed

    Carey, Robert J; DePalma, Gail; Damianopoulos, Ernest

    2003-07-01

    An animal's response to novelty has been suggested to be a predictor of its response to drugs of abuse. The possible relationship between an individual's behavioral response to novelty and its subsequent behavioral response to cocaine has not been subjected to a detailed correlational analysis. To use a repeated cocaine treatment protocol to induce cocaine sensitization and conditioned cocaine locomotor stimulant effects and to assess the relationship of these effects to pre-cocaine locomotor behavior in a novel environment. In two separate experiments, rats were given a 20-min test in a novel open-field environment. Subsequently, the rats were given a series of additional tests in conjunction with either saline or cocaine (10 mg/kg) treatments to induce cocaine sensitization and conditioned effects. The repeated cocaine treatments induced cocaine behavioral sensitization and conditioned effects. Correlational analyses showed that the initial 20-min novel environment test proved to be a strong predictor of an animal's subsequent saline activity level but did not predict the rats' behavioral acute and sensitized response to cocaine. When change in activity was used as the dependent variable, initial activity level was reliably negatively correlated with activity changes on cocaine tests as well as cocaine conditioning tests. The negative correlation between initial activity in a novel environment and the change in activity induced by cocaine indicates that low responders to environmental novelty tend to have the strongest response to cocaine. These results appear consistent with the classic initial value and response rate dependent analyses of stimulant drug effects.

  14. Neurocognitive Function in Children with Primary Hypertension after Initiation of Antihypertensive Therapy.

    PubMed

    Lande, Marc B; Batisky, Donald L; Kupferman, Juan C; Samuels, Joshua; Hooper, Stephen R; Falkner, Bonita; Waldstein, Shari R; Szilagyi, Peter G; Wang, Hongyue; Staskiewicz, Jennifer; Adams, Heather R

    2018-04-01

    To determine the change in neurocognitive test performance in children with primary hypertension after initiation of antihypertensive therapy. Subjects with hypertension and normotensive control subjects had neurocognitive testing at baseline and again after 1 year, during which time the subjects with hypertension received antihypertensive therapy. Subjects completed tests of general intelligence, attention, memory, executive function, and processing speed, and parents completed rating scales of executive function. Fifty-five subjects with hypertension and 66 normotensive control subjects underwent both baseline and 1-year assessments. Overall, the blood pressure (BP) of subjects with hypertension improved (24-hour systolic BP load: mean baseline vs 1 year, 58% vs 38%, P < .001). Primary multivariable analyses showed that the hypertension group improved in scores of subtests of the Rey Auditory Verbal Learning Test, Grooved Pegboard, and Delis-Kaplan Executive Function System Tower Test (P < .05). However, the control group also improved in the same measures with similar effects sizes. Secondary analyses by effectiveness of antihypertensive therapy showed that subjects with persistent ambulatory hypertension at 1 year (n = 17) did not improve in subtests of Rey Auditory Verbal Learning Test and had limited improvement in Grooved Pegboard. Overall, children with hypertension did not improve in neurocognitive test performance after 1 year of antihypertensive therapy, beyond that also seen in normotensive controls, suggesting improvements with age or practice effects because of repeated neurocognitive testing. However, the degree to which antihypertensive therapy improves BP may affect its impact upon neurocognitive function. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Development of radiation resistant electrical cable insulations

    NASA Technical Reports Server (NTRS)

    Lee, B. S.; Soo, P.; Mackenzie, D. R.

    1994-01-01

    Two new polyethylene cable insulations have been formulated for nuclear applications and have been tested under gamma radiation. Both insulations are based on low density polyethylene, one with PbO and the other with Sb2O3 as additives. The test results show that the concept of using inorganic antioxidants to retard radiation initiated oxidation (RIO) is viable. PbO is more effective than Sb2O3 in minimizing RIO.

  16. Sensitivity and validity of psychometric tests for assessing driving impairment: effects of sleep deprivation.

    PubMed

    Jongen, Stefan; Perrier, Joy; Vuurman, Eric F; Ramaekers, Johannes G; Vermeeren, Annemiek

    2015-01-01

    To assess drug induced driving impairment, initial screening is needed. However, no consensus has been reached about which initial screening tools have to be used. The present study aims to determine the ability of a battery of psychometric tests to detect performance impairing effects of clinically relevant levels of drowsiness as induced by one night of sleep deprivation. Twenty four healthy volunteers participated in a 2-period crossover study in which the highway driving test was conducted twice: once after normal sleep and once after one night of sleep deprivation. The psychometric tests were conducted on 4 occasions: once after normal sleep (at 11 am) and three times during a single night of sleep deprivation (at 1 am, 5 am, and 11 am). On-the-road driving performance was significantly impaired after sleep deprivation, as measured by an increase in Standard Deviation of Lateral Position (SDLP) of 3.1 cm compared to performance after a normal night of sleep. At 5 am, performance in most psychometric tests showed significant impairment. As expected, largest effect sizes were found on performance in the Psychomotor Vigilance Test (PVT). Large effects sizes were also found in the Divided Attention Test (DAT), the Attention Network Test (ANT), and the test for Useful Field of View (UFOV) at 5 and 11 am during sleep deprivation. Effects of sleep deprivation on SDLP correlated significantly with performance changes in the PVT and the DAT, but not with performance changes in the UFOV. From the psychometric tests used in this study, the PVT and DAT seem most promising for initial evaluation of drug impairment based on sensitivity and correlations with driving impairment. Further studies are needed to assess the sensitivity and validity of these psychometric tests after benchmark sedative drug use.

  17. 77 FR 73056 - Initial Test Programs for Water-Cooled Nuclear Power Plants

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-07

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0293] Initial Test Programs for Water-Cooled Nuclear Power... (DG), DG-1259, ``Initial Test Programs for Water-Cooled Nuclear Power Plants.'' This guide describes the general scope and depth that the staff of the NRC considers acceptable for Initial Test Programs...

  18. 77 FR 36014 - Initial Test Program of Emergency Core Cooling Systems for Boiling-Water Reactors

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-15

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0134] Initial Test Program of Emergency Core Cooling... for public comment draft regulatory guide (DG), DG-1277, ``Initial Test Program of Emergency Core... acceptable to implement with regard to initial testing features of emergency core cooling systems (ECCSs) for...

  19. Two-dimensional computational modeling of high-speed transient flow in gun tunnel

    NASA Astrophysics Data System (ADS)

    Mohsen, A. M.; Yusoff, M. Z.; Hasini, H.; Al-Falahi, A.

    2018-03-01

    In this work, an axisymmetric numerical model was developed to investigate the transient flow inside a 7-meter-long free piston gun tunnel. The numerical solution of the gun tunnel was carried out using the commercial solver Fluent. The governing equations of mass, momentum, and energy were discretized using the finite volume method. The dynamic zone of the piston was modeled as a rigid body, and its motion was coupled with the hydrodynamic forces from the flow solution based on the six-degree-of-freedom solver. A comparison of the numerical data with the theoretical calculations and experimental measurements of a ground-based gun tunnel facility showed good agreement. The effects of parameters such as working gases and initial pressure ratio on the test conditions in the facility were examined. The pressure ratio ranged from 10 to 50, and gas combinations of air-air, helium-air, air-nitrogen, and air-CO2 were used. The results showed that steady nozzle reservoir conditions can be maintained for a longer duration when the initial conditions across the diaphragm are adjusted. It was also found that the gas combination of helium-air yielded the highest shock wave strength and speed, but a longer test time was achieved in the test section when using the CO2 test gas.

  20. Testing and Analysis of Composite Skin/Stringer Debonding Under Multi-Axial Loading

    NASA Technical Reports Server (NTRS)

    Krueger, Ronald; Cvitkovich, Michael K.; OBrien, T. Kevin; Minguet, Pierre J.

    1999-01-01

    Damage mechanisms in composite bonded skin/stringer constructions under uniaxial and biaxial (in-plane/out- of-plane) loading conditions were examined. Specimens consisted of a tapered composite flange bonded onto a composite skin. Tests were performed under monotonic loading conditions in tension, three-point bending, and combined tension/bending . For combined tension/bending testing, a unique servohydraulic load frame was used that was capable of applying both in-plane tension and out-of-plane bending loads simultaneously. Specimen edges were examined on the microscope to document the damage occurrence and to identify typical damage patterns. The observations showed that, for all three load cases, failure initiated in the flange, near the flange tip, causing the flange to almost fully debond from the skin. A two-dimensional plane-strain finite element model was developed to analyze the different test cases using a geometrically nonlinear solution. For all three loading conditions, principal stresses exceeded the transverse strength of the material in the flange area. Additionally, delaminations of various lengths were simulated in two locations where delaminations were observed. The analyses showed that unstable delamination propagation is likely to occur in one location at the loads corresponding to matrix ply crack initiation for all three load cases.

  1. Diminished testing benefits in young adults with attention-deficit hyperactivity disorder.

    PubMed

    Dudukovic, Nicole M; Gottshall, Jackie L; Cavanaugh, Patricia A; Moody, Christine T

    2015-01-01

    Memory retrieval has been shown to enhance the long-term retention of tested material; however, recent research suggests that limiting attention during retrieval can decrease the benefits of testing memory. The present study examined whether testing benefits are reduced in young adults with attention-deficit hyperactivity disorder (ADHD). College students with and without ADHD read three short prose passages, each followed by a free recall test, a restudy period or a distractor task. Two days later participants recalled the passages. Although participants without ADHD did not show a significant benefit of testing over restudying, testing did produce recall benefits relative to not taking a test. These testing benefits were diminished in participants with ADHD, who did not show any advantage of testing over either restudying or no test. The absence of testing benefits in the ADHD group is likely due in part to decreased recall on the initial test. These findings have implications for improving educational practices among individuals with ADHD and also speak to the need to examine individual differences in the effectiveness of testing as a learning strategy.

  2. [Lupus enteritis as initial manifestation of systemic lupus erythematosus. Report of one case].

    PubMed

    Barrera O, Manuel; Barrera M, Rodrigo; de la Rivera V, Matías; Vela U, Javier; Mönckeberg F, Gustavo

    2017-10-01

    Although gastrointestinal symptoms are not rare in Systemic lupus erythematosus, enteritis is an atypical manifestation of the disease. We report a 54 year-old woman who presented acute symptoms of diarrhea, fever and abdominal pain, receiving empiric antibiotic therapy for bacterial enteritis with no response. Computed tomography showed diffuse small intestine inflammation and serositis. Antinuclear antibodies, anti-Ro and anti-La were positive on blood tests. A lupic enteropathy was diagnosed and steroid treatment was initiated, with subsequent clinical improvement.

  3. Acceleration of Intended Pozzolanic Reaction under Initial Thermal Treatment for Developing Cementless Fly Ash Based Mortar.

    PubMed

    Kwon, Yang-Hee; Kang, Sung-Hoon; Hong, Sung-Gul; Moon, Juhyuk

    2017-02-24

    Without using strong alkaline solution or ordinary Portland cement, a new structural binder consisting of fly ash and hydrated lime was hardened through an intensified pozzolanic reaction. The main experimental variables are the addition of silica fume and initial thermal treatment (60 °C for 3 days). A series of experiments consisting of mechanical testing (compressive and flexural strength, modulus of elasticity), X-ray diffraction, and measurements of the heat of hydration, pore structure, and shrinkage were conducted. These tests show that this new fly ash-based mortar has a compressive strength of 15 MPa at 91 days without any silica fume addition or initial thermal treatment. The strength increased to over 50 MPa based on the acceleration of the intensified pozzolanic reaction from the silica fume addition and initial thermal treatment. This is explained by a significant synergistic effect induced by the silica fume. It intensifies the pozzolanic reaction under thermal treatment and provides a space filling effect. This improved material performance can open a new pathway to utilize the industrial by-product of fly ash in cementless construction materials.

  4. Orion Parachute Riser Cutter Development

    NASA Technical Reports Server (NTRS)

    Oguz, Sirri; Salazar, Frank

    2011-01-01

    This paper presents the tests and analytical approach used on the development of a steel riser cutter for the CEV Parachute Assembly System (CPAS) used on the Orion crew module. Figure 1 shows the riser cutter and the steel riser bundle which consists of six individual cables. Due to the highly compressed schedule, initial unavailability of the riser material and the Orion Forward Bay mechanical constraints, JSC primarily relied on a combination of internal ballistics analysis and LS-DYNA simulation for this project. Various one dimensional internal ballistics codes that use standard equation of state and conservation of energy have commonly used in the development of CAD devices for initial first order estimates and as an enhancement to the test program. While these codes are very accurate for propellant performance prediction, they usually lack a fully defined kinematic model for dynamic predictions. A simple piston device can easily and accurately be modeled using an equation of motion. However, the accuracy of analytical models is greatly reduced on more complicated devices with complex external loads, nonlinear trajectories or unique unlocking features. A 3D finite element model of CAD device with all critical features included can vastly improve the analytical ballistic predictions when it is used as a supplement to the ballistic code. During this project, LS-DYNA structural 3D model was used to predict the riser resisting load that was needed for the ballistic code. A Lagrangian model with eroding elements shown in Figure 2 was used for the blade, steel riser and the anvil. The riser material failure strain was fine tuned by matching the dent depth on the anvil with the actual test data. LS-DYNA model was also utilized to optimize the blade tip design for the most efficient cut. In parallel, the propellant type and the amount were determined by using CADPROG internal ballistics code. Initial test results showed a good match with LS-DYNA and CADPROG simulations. Final paper will present a detailed roadmap from initial ballistic modeling and LS-DYNA simulation to the performance testing. Blade shape optimization study will also be presented.

  5. Toward lean satellites reliability improvement using HORYU-IV project as case study

    NASA Astrophysics Data System (ADS)

    Faure, Pauline; Tanaka, Atomu; Cho, Mengu

    2017-04-01

    Lean satellite programs are programs in which the satellite development philosophy is driven by fast delivery and low cost. Though this concept offers the possibility to develop and fly risky missions without jeopardizing a space program, most of these satellites suffer infant mortality and fail to achieve their mission minimum success. Lean satellites with high infant mortality rate indicate that testing prior to launch is insufficient. In this study, the authors monitored failures occurring during the development of the lean satellite HORYU-IV to identify the evolution of the cumulative number of failures against cumulative testing time. Moreover, the sub-systems driving the failures depending on the different development phases were identified. The results showed that half to 2/3 of the failures are discovered during the early stage of testing. Moreover, when the mean time before failure was calculated, it appeared that for any development phase considered, a new failure appears on average every 20 h of testing. Simulations were also performed and it showed that for an initial testing time of 50 h, reliability after 1 month launch can be improved by nearly 6 times as compared to an initial testing time of 20 h. Through this work, the authors aim at providing a qualitative reference for lean satellites developers to better help them manage resources to develop lean satellites following a fast delivery and low cost philosophy while ensuring sufficient reliability to achieve mission minimum success.

  6. Active learning of geometrical optics in high school: the ALOP approach

    NASA Astrophysics Data System (ADS)

    Alborch, Alejandra; Pandiella, Susana; Benegas, Julio

    2017-09-01

    A group comparison experiment of two high school classes with pre and post instruction testing has been carried out to study the suitability and advantages of using the active learning of optics and photonics (ALOP) curricula in high schools of developing countries. Two parallel, mixed gender, 12th grade classes of a high school run by the local university were chosen. One course was randomly selected to follow the experimental instruction, based on teacher and student activities contained in the ALOP Manual. The other course followed the traditional, teacher-centered, instruction previously practiced. Conceptual knowledge of the characteristics of image formation by plane mirrors and single convergent and divergent lenses was measured by applying, in both courses, the multiple-choice test, light and optics conceptual evaluation (LOCE). Measurement before instruction showed that initial knowledge was almost null, and therefore equivalent, in both courses. After instruction testing showed that the conceptual knowledge of students following the ALOP curricula more than doubled that achieved by students in the control course, a situation maintained throughout the six conceptual dimensions tested by the 34 questions of the LOCE test used in this experiment. Using a 60% performance level on the LOCE test as the threshold of satisfactory performance, most (about 90%) of the experimental group achieved this level—independent of initial knowledge, while no student following traditional instruction reached this level of understanding. Some considerations and recommendations for prospective users are also included.

  7. Treatment retention in a prison-based residential sex offender treatment program.

    PubMed

    Pelissier, Bernadette

    2007-12-01

    This study assessed the role of static factors, a dynamic factor (motivation to change sexually deviant behavior), and an administrative factor in predicting treatment retention within a prison-based sex offender treatment program. The analyses also included assessing differences in initial levels of motivation and differences in beginning-versus end-of-treatment motivation scores for various types of program discharges. The sample consisted of 251 individuals who were admitted to a residential prison-based sex offender treatment program where 46% completed the program. Paired comparison t-tests showed higher motivation scores at the end of treatment only among treatment completers. Multivariate analyses showed that treatment retention was associated with higher initial motivation scores, higher levels of education and admission to treatment within 3 months of initial commitment to prison. Implications for motivational enhancement programming as well as for changes in admission criteria are discussed.

  8. Microstructure and Texture Evolutions of Biomedical Ti-13Nb-13Zr Alloy Processed by Hydrostatic Extrusion

    NASA Astrophysics Data System (ADS)

    Ozaltin, K.; Panigrahi, A.; Chrominski, W.; Bulutsuz, A. G.; Kulczyk, M.; Zehetbauer, M. J.; Lewandowska, M.

    2017-11-01

    A biomedical β-type Ti-13Nb-13Zr (TNZ) (wt pct) ternary alloy was subjected to severe plastic deformation by means of hydrostatic extrusion (HE) at room temperature without intermediate annealing. Its effect on microstructure, mechanical properties, phase transformations, and texture was investigated by light and electron microscopy, mechanical tests (Vickers microhardness and tensile tests), and XRD analysis. Microstructural investigations by light microscope and transmission electron microscope showed that, after HE, significant grain refinement took place, also reaching high dislocation densities. Increases in strength up to 50 pct occurred, although the elongation to fracture left after HE was almost 9 pct. Furthermore, Young's modulus of HE-processed samples showed slightly lower values than the initial state due to texture. Such mechanical properties combined with lower Young's modulus are favorable for medical applications. Phase transformation analyses demonstrated that both initial and extruded samples consist of α' and β phases but that the phase fraction of α' was slightly higher after two stages of HE.

  9. On fractography of shallow and deep HY-100 cracked bend specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan, D.W.; Zarzour, J.F.; Kleinosky, M.J.

    1994-12-01

    The influence of shallow cracks on the fracture behavior of structural components has been studied extensively in recent years. Finite element analyses have indicated dramatic differences in the crack-tip stress states between shallow and deep cracked bend specimens. In this study, an experimental program was carried out to investigate the fracture behavior of HY-100 steel containing various initial flaw depths. Four a/w ratios ranging from 0.05 to 0.5 were chosen for the notched three-point bend tests. Test results showed that higher fracture toughness values are associated with specimens having shorter surface cracks. Also, fractographic studies indicated that two sets ofmore » dimples are present for a/w = 0.5 specimen, one set of equiaxed dimple for a/w = 0.05 specimen near the crack initiation zone. As the crack grows, increase in the volume fraction of the small dimple were observed. Finally, it showed that the characteristic features of the fracture surfaces can be correlated with the previous numerical predictions.« less

  10. Fulminate Hepatic Failure as an Initial Presentation of Non-Hodgkin Lymphoma: A Case Report

    PubMed Central

    Ahmadi, Bizhan; Shafieipour, Sara; Akhavan Rezayat, Kambiz

    2014-01-01

    Viral hepatitis and toxins comprise most common causes of fulminate hepatic failure that are often diagnosed with standard laboratory tests. Herein we discuss a rare, difficult to diagnosis etiology of acute liver failure (ALF). A 62-year-old man presented with a two-week history of fever and fatigue. At four days before admission he became lethargic. His past medical and drug histories were unremarkable. Physical examination revealed generalized jaundice, fever and loss of consciousness. Laboratory tests showed elevated liver transaminases with direct hyper-bilirubinemia. Abdominal ultrasonography and CT scan showed hepatosplenomegaly and para-aortic abdominal lymphadenopathy. A further work-up included liver biopsy. The histopathology and imunohistochemistry was compatible with diffuse large B-cell lymphoma. He underwent high dose glucocorticoid therapy but his condition deteriorated rapidly and he died eight days after admission. ALF as an initial manifestation of malignant hepatic infiltration is extremely rare yet should be considered in all patients with unknown hepatic failure that are highly suspicious for malignant neoplasm. PMID:24872870

  11. Study of foldable elastic tubes for large space structure applications, phase 3

    NASA Technical Reports Server (NTRS)

    Jones, I. W.; Mitchell, S. O.

    1981-01-01

    A bi-convex foldable elastic tube, suitable for use in self deploying space structures, was subjected to a series of buckling tests to deterine initial buckling loads, collapse loads, and the buckling mode. The tube is cylindrical with a cross-section that is lenticular-like with flared edges. It is capable of being flattened in the center and folded compactly, storing up strain energy in the process. Upon removal of constraint, it springs back to its original straight configuration, releasing the stored strain energy. The tests showed that this type of tube has good resistance to buckling, with the initial buckling loads all falling within or above the range of those for comparable circular cylindrical tubes.

  12. Equipment. [for testing human space perception

    NASA Technical Reports Server (NTRS)

    1974-01-01

    A discussion is presented on the problems encountered in designing and constructing a simulator to determine human vestibular response to a range of linear accelerations from 0 to 0.3 g's. Starting with a set of initial performance specifications, the designers combined an array of commercially available components into a system which, altough requiring further refinement before completion, shows considerable promise of fulfilling the initial requirements. The resulting system consists of a wheeled vehicle driven by a cable and drum arrangement, powered by a hydraulic-electric servo-valve. Technical design considerations are presented along with a discussion of the trade-offs between various component options. A description of the system characteristics as well as an analysis of preliminary test results and recommendations for future system improvements are included.

  13. Multifunctional Characteristics of Carbon Nanotube (CNT) Yarn Composites

    NASA Technical Reports Server (NTRS)

    Hernandez, Corey D.; Zhang, Mei; Fang, Shaoli; Baughman, Ray H.; Gates, Thomas S.; Kahng, Seun K.

    2006-01-01

    By forming composite structures with Carbon Nanotube (CNT) yarns we achieve materials capable of measuring strain and composite structures with increased mechanical strength. The CNT yarns used are of the 2-ply and 4-ply variety with the yarns having diameters of about 15-30 micrometers. The strain sensing characteristics of the yarns are investigated on test beams with the yarns arranged in a bridge configuration. Additionally, the strain sensing properties are also investigated on yarns embedded on the surface of a flexible membrane. Initial mechanical strength tests also show an increase in the modulus of elasticity of the composite materials while incurring a weight penalty of less than one-percent. Also presented are initial temperature characterizations of the yarns.

  14. Impact-initiated damage thresholds in composites

    NASA Technical Reports Server (NTRS)

    Sharma, A. V.

    1980-01-01

    An experimental investigation was conducted to study the effect of low velocity projectile impact on the sandwich-type structural components. The materials used in the fabrication of the impact surface were graphite-, Kevlar-, and boron-fibers with appropriate epoxy matrices. The testing of the specimens was performed at moderately low- and high-temperatures as well as at room temperature to assess the impact-initiated strength degradation of the laminates. Eleven laminates with different stacking sequences, orientations, and thicknesses were tested. The low energy projectile impact is considered to simulate the damage caused by runway debris, dropping of the hand tools during servicing, etc., on the secondary aircraft structures fabricated with the composite materials. The results show the preload and the impact energy combinations necessary to cause catastrophic failures in the laminates tested. A set of faired curves indicating the failure thresholds is shown separately for the tension- and compression-loaded laminates. The specific-strengths and -moduli for the various laminates tested are also given.

  15. Proposal of e-learning strategy to teach Atraumatic Restorative Treatment (ART) to undergraduate and graduate students.

    PubMed

    Camargo, Lucila Basto; Raggio, Daniela Prócida; Bonacina, Carlos Felipe; Wen, Chao Lung; Mendes, Fausto Medeiros; Bönecker, Marcelo José Strazzeri; Haddad, Ana Estela

    2014-07-17

    The aim of this study was to evaluate e-learning strategy in teaching Atraumatic Restorative Treatment (ART) to undergraduate and graduate students. The sample comprised 76 participants-38 dental students and 38 pediatric dentistry students-in a specialization course. To evaluate knowledge improvement, participants were subjected to a test performed before and after the course. A single researcher corrected the tests and intraexaminer reproducibility was calculated (CCI = 0.991; 95% IC = 0.975-0.996). All students improved their performances after the e-learning course (Paired t-tests p < 0.001). The means of undergraduate students were 4.7 (initial) and 6.4 (final) and those of graduate students were 6.8 (initial) and 8.2 (final). The comparison of the final evaluation means showed a statistically significant difference (t-tests p < 0.0001). The e-learning strategy has the potential of improving students' knowledge in ART. Mature students perform better in this teaching modality when it is applied exclusively via distance learning.

  16. Real-Time Sensor Validation, Signal Reconstruction, and Feature Detection for an RLV Propulsion Testbed

    NASA Technical Reports Server (NTRS)

    Jankovsky, Amy L.; Fulton, Christopher E.; Binder, Michael P.; Maul, William A., III; Meyer, Claudia M.

    1998-01-01

    A real-time system for validating sensor health has been developed in support of the reusable launch vehicle program. This system was designed for use in a propulsion testbed as part of an overall effort to improve the safety, diagnostic capability, and cost of operation of the testbed. The sensor validation system was designed and developed at the NASA Lewis Research Center and integrated into a propulsion checkout and control system as part of an industry-NASA partnership, led by Rockwell International for the Marshall Space Flight Center. The system includes modules for sensor validation, signal reconstruction, and feature detection and was designed to maximize portability to other applications. Review of test data from initial integration testing verified real-time operation and showed the system to perform correctly on both hard and soft sensor failure test cases. This paper discusses the design of the sensor validation and supporting modules developed at LeRC and reviews results obtained from initial test cases.

  17. Double torsion fracture mechanics testing of shales under chemically reactive conditions

    NASA Astrophysics Data System (ADS)

    Chen, X.; Callahan, O. A.; Holder, J. T.; Olson, J. E.; Eichhubl, P.

    2015-12-01

    Fracture properties of shales is vital for applications such as shale and tight gas development, and seal performance of carbon storage reservoirs. We analyze the fracture behavior from samples of Marcellus, Woodford, and Mancos shales using double-torsion (DT) load relaxation fracture tests. The DT test allows the determination of mode-I fracture toughness (KIC), subcritical crack growth index (SCI), and the stress-intensity factor vs crack velocity (K-V) curves. Samples are tested at ambient air and aqueous conditions with variable ionic concentrations of NaCl and CaCl2, and temperatures up to 70 to determine the effects of chemical/environmental conditions on fracture. Under ambient air condition, KIC determined from DT tests is 1.51±0.32, 0.85±0.25, 1.08±0.17 MPam1/2 for Marcellus, Woodford, and Mancos shales, respectively. Tests under water showed considerable change of KIC compared to ambient condition, with 10.6% increase for Marcellus, 36.5% decrease for Woodford, and 6.7% decrease for Mancos shales. SCI under ambient air condition is between 56 and 80 for the shales tested. The presence of water results in a significant reduction of the SCI from 70% to 85% compared to air condition. Tests under chemically reactive solutions are currently being performed with temperature control. K-V curves under ambient air conditions are linear with stable SCI throughout the load-relaxation period. However, tests conducted under water result in an initial cracking period with SCI values comparable to ambient air tests, which then gradually transition into stable but significantly lower SCI values of 10-20. The non-linear K-V curves reveal that crack propagation in shales is initially limited by the transport of chemical agents due to their low permeability. Only after the initial cracking do interactions at the crack tip lead to cracking controlled by faster stress corrosion reactions. The decrease of SCI in water indicates higher crack propagation velocity due to faster stress corrosion rate in water than in ambient air. The experimental results are applicable for the prediction of fracture initiation based on KIC, modeling fracture pattern based on SCI, and the estimation of dynamic fracture propagation such as crack growth velocity and crack re-initiation.

  18. The Impact of Recreational Marijuana Legislation in Washington, DC on Marijuana Use Cognitions.

    PubMed

    Clarke, Paige; Dodge, Tonya; Stock, Michelle L

    2018-04-13

    There is little published research that tests the effect of recreational marijuana legislation on risk-related cognitions and how individuals respond immediately after legislative approval. The objective was to test whether learning about the passage of Initiative 71, a voter referendum that legalized recreational use of marijuana in the District of Columbia, would lead individuals to adopt more favorable marijuana cognitions than they had before the Initiative was passed. Undergraduate students (N = 402) completed two web-based questionnaires in 2014. The first questionnaire was completed prior to the referendum vote and the follow-up questionnaire was completed after voters approved Initiative 71. Attitudes, perceived norms, intentions, prototypes, and willingness were measured at time 1 and time 2. Study hypotheses were tested using repeated-measures analysis of covariance. Results showed that attitudes, intentions, perceived norms, and willingness to use marijuana were more favorable after Initiative 71 was passed. However, the increase in attitudes and willingness was moderated by past experience with marijuana whereby the increases were statistically significant only among those with the least experience. The increase in perceived norms was also moderated by past experience whereby increases were statistically significant among those who were moderate or heavy users. The passage of Initiative 71 had no effect on favorable prototypes. Conclusion/Importance: Legalization may have the unintended outcome of leading to more favorable intentions to use marijuana and might lead abstainers or experimental users to become more frequent users of marijuana via more positive attitudes and willingness towards marijuana use.

  19. Development and testing of a high cycle life 30 A-h sealed AgO-Zn battery

    NASA Technical Reports Server (NTRS)

    Bogner, R. S.

    1972-01-01

    A two-phase program was initiated to investigate design parameters and technology to develop an improved AgO-Zn battery. The basic performance goal was 100 charge/discharge cycles (22 h/2 h) at 50 percent depth of discharge following a six-month period of charged stand at room temperature. Phase 1, cell evaluation, involved testing 70 cells in five-cell groups. The major design variables were active material ratios, electrolyte concentrations, separator systems, and negative plate shape. Phase 1 testing showed that cycle life could be improved 10 percent to 20 percent by using greater ratios of zinc to silver oxide and higher electrolyte concentrations. Wedge-shaped negatives increased cycle life by nearly 100 percent. Phase 2 battery evaluation, which was initiated before the Phase 1 results were known completely, involved evaluation of six designs as 19-cell batteries. Only one battery exceeded 100 cycles following nine months charged stand.

  20. Functional Analysis of Problem Behavior: A Systematic Approach for Identifying Idiosyncratic Variables

    PubMed Central

    Roscoe, Eileen M.; Schlichenmeyer, Kevin J.; Dube, William V.

    2015-01-01

    When inconclusive functional analysis (FA) outcomes occur, a number of modifications have been made to enhance the putative establishing operation or consequence associated with behavioral maintenance. However, a systematic method for identifying relevant events to test during modified FAs has not been evaluated. The purpose of this study was to develop and evaluate a technology for systematically identifying events to test in a modified FA after an initial FA led to inconclusive outcomes. Six individuals whose initial FA showed little or no responding or high levels only in the control condition participated. An indirect assessment (IA) questionnaire developed for identifying idiosyncratic variables was administered, and a descriptive analysis (DA) was conducted. Results from the IA only or a combination of the IA and DA were used to inform modified FA test and control conditions. Conclusive FA outcomes were obtained with five of the six participants during the modified FA phase. PMID:25930176

  1. TRAC-PF1/MOD1 pretest predictions of MIST experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyack, B.E.; Steiner, J.L.; Siebe, D.A.

    Los Alamos National Laboratory is a participant in the Integral System Test (IST) program initiated in June 1983 to provide integral system test data on specific issues and phenomena relevant to post small-break loss-of-coolant accidents (SBLOCAs) in Babcock and Wilcox plant designs. The Multi-Loop Integral System Test (MIST) facility is the largest single component in the IST program. During Fiscal Year 1986, Los Alamos performed five MIST pretest analyses. The five experiments were chosen on the basis of their potential either to approach the facility limits or to challenge the predictive capability of the TRAC-PF1/MOD1 code. Three SBLOCA tests weremore » examined which included nominal test conditions, throttled auxiliary feedwater and asymmetric steam-generator cooldown, and reduced high-pressure-injection (HPI) capacity, respectively. Also analyzed were two ''feed-and-bleed'' cooling tests with reduced HPI and delayed HPI initiation. Results of the tests showed that the MIST facility limits would not be approached in the five tests considered. Early comparisons with preliminary test data indicate that the TRAC-PF1/MOD1 code is correctly calculating the dominant phenomena occurring in the MIST facility during the tests. Posttest analyses are planned to provide a quantitative assessment of the code's ability to predict MIST transients.« less

  2. Progress of Ongoing NASA Lithium-Ion Cell Verification Testing for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    McKissock, Barbara I.; Manzo, Michelle A.; Miller, Thomas B.; Reid, Concha M.; Bennett, William R.; Gemeiner, Russel

    2008-01-01

    A Lithium-ion Verification and Validation Program with the purpose to assess the capabilities of current aerospace lithium-ion (Li-ion) battery cells to perform in a low-earth-orbit (LEO) regime was initiated in 2002. This program involves extensive characterization and LEO life testing at ten different combinations of depth-of-discharge, temperature, and end-of-charge voltage. The test conditions selected for the life tests are defined as part of a statistically designed test matrix developed to determine the effects of operating conditions on performance and life of Li-ion cells. Results will be used to model and predict cell performance and degradation as a function of test operating conditions. Testing is being performed at the Naval Surface Warfare Center/Crane Division in Crane, Indiana. Testing was initiated in September 2004 with 40 Ah cells from Saft and 30 Ah cells from Lithion. The test program has been expanded with the addition of modules composed of 18650 cells from ABSL Power Solutions in April 2006 and the addition of 50 Ah cells from Mine Safety Appliances Co. (MSA) in June 2006. Preliminary results showing the average voltage and average available discharge capacity for the Saft and Lithion packs at the test conditions versus cycles are presented.

  3. Success rate and risk factors for failure of empirical antifungal therapy with itraconazole in patients with hematological malignancies: a multicenter, prospective, open-label, observational study in Korea.

    PubMed

    Kim, Soo-Jeong; Cheong, June-Won; Min, Yoo Hong; Choi, Young Jin; Lee, Dong-Gun; Lee, Je-Hwan; Yang, Deok-Hwan; Lee, Sang Min; Kim, Sung-Hyun; Kim, Yang Soo; Kwak, Jae-Yong; Park, Jinny; Kim, Jin Young; Kim, Hoon-Gu; Kim, Byung Soo; Ryoo, Hun-Mo; Jang, Jun Ho; Kim, Min Kyoung; Kang, Hye Jin; Cho, In Sung; Mun, Yeung Chul; Jo, Deog-Yeon; Kim, Ho Young; Park, Byeong-Bae; Kim, Jin Seok

    2014-01-01

    We assessed the success rate of empirical antifungal therapy with itraconazole and evaluated risk factors for predicting the failure of empirical antifungal therapy. A multicenter, prospective, observational study was performed in patients with hematological malignancies who had neutropenic fever and received empirical antifungal therapy with itraconazole at 22 centers. A total of 391 patients who had abnormal findings on chest imaging tests (31.0%) or a positive result of enzyme immunoassay for serum galactomannan (17.6%) showed a 56.5% overall success rate. Positive galactomannan tests before the initiation of the empirical antifungal therapy (P=0.026, hazard ratio [HR], 2.28; 95% confidence interval [CI], 1.10-4.69) and abnormal findings on the chest imaging tests before initiation of the empirical antifungal therapy (P=0.022, HR, 2.03; 95% CI, 1.11-3.71) were significantly associated with poor outcomes for the empirical antifungal therapy. Eight patients (2.0%) had premature discontinuation of itraconazole therapy due to toxicity. It is suggested that positive galactomannan tests and abnormal findings on the chest imaging tests at the time of initiation of the empirical antifungal therapy are risk factors for predicting the failure of the empirical antifungal therapy with itraconazole. (Clinical Trial Registration on National Cancer Institute website, NCT01060462).

  4. In vitro assessment of artificial saliva formulations on initial enamel erosion remineralization.

    PubMed

    Ionta, Franciny Querobim; Mendonça, Fernanda Lyrio; de Oliveira, Gabriela Cristina; de Alencar, Catarina Ribeiro Barros; Honório, Heitor Marques; Magalhães, Ana Carolina; Rios, Daniela

    2014-02-01

    Various formulations of artificial saliva are present in the literature and little guidance is available on the standardization of type of saliva for use in in vitro protocols for erosive studies. The aim of this study was to evaluate the remineralizing capacity of different formulations of artificial saliva on initial enamel erosive lesion. Bovine enamel blocks were subjected to short-term acidic exposure by immersion in citric acid 0.05 M (pH 2.5) for 15s, resulting in surface softening without tissue loss. Then 90 selected eroded enamel blocks were randomly and equally divided into 6 groups according to saliva formulation (n=15): Saliva 1 (contain mucin); Saliva 2 (Saliva 1 without mucin); Saliva 3; Saliva 4; Saliva 5 (contain sodium carboxymethyl cellulose) and control (C) (deionized water). After demineralization enamel blocks were subjected to remineralization by immersion in the saliva's formulations for 2h. Enamel remineralization was measured by superficial hardness test (% superficial hardness change). The data were tested using ANOVA and Tukey's test (p<0.05). All the tested formulations of artificial saliva resulted in significantly higher enamel remineralization compared to control (p<0.001). Saliva 3 showed higher percentage of enamel remineralization than Saliva 5 (p<0.05). Besides the variety of artificial saliva for erosion in vitro protocols, all the formulations tested were able to partially remineralize initial erosive lesions. Copyright © 2013. Published by Elsevier Ltd.

  5. The predictive value of respiratory function tests for non-invasive ventilation in amyotrophic lateral sclerosis.

    PubMed

    Tilanus, T B M; Groothuis, J T; TenBroek-Pastoor, J M C; Feuth, T B; Heijdra, Y F; Slenders, J P L; Doorduin, J; Van Engelen, B G; Kampelmacher, M J; Raaphorst, J

    2017-07-25

    Non-invasive ventilation (NIV) improves survival and quality of life in amyotrophic lateral sclerosis (ALS) patients. The timing of referral to a home ventilation service (HVS), which is in part based on respiratory function tests, has shown room for improvement. It is currently unknown which respiratory function test predicts an appropriate timing of the initiation of NIV. We analysed, retrospectively, serial data of five respiratory function tests: forced vital capacity (FVC), peak cough flow (PCF), maximum inspiratory and expiratory pressure (MIP and MEP) and sniff nasal inspiratory pressure (SNIP) in patients with ALS. Patients who had had at least one assessment of respiratory function and one visit at the HVS, were included. Our aim was to detect the test with the highest predictive value for the need for elective NIV in the following 3 months. We analysed time curves, currently used cut-off values for referral, and respiratory function test results between 'NIV indication' and 'no-NIV indication' patients. One hundred ten patients with ALS were included of whom 87 received an NIV indication; 11.5% had one assessment before receiving an NIV indication, 88.5% had two or more assessments. The NIV indication was based on complaints of hypoventilation and/or proven (nocturnal) hypercapnia. The five respiratory function tests showed a descending trend during disease progression, where SNIP showed the greatest decline within the latest 3 months before NIV indication (mean = -22%). PCF at the time of referral to the HVS significantly discriminated between the groups 'NIV-indication' and 'no NIV-indication yet' patients at the first HVS visit: 259 (±92) vs. 348 (±137) L/min, p = 0.019. PCF and SNIP showed the best predictive characteristics in terms of sensitivity. SNIP showed the greatest decline prior to NIV indication and PCF significantly differentiated 'NIV-indication' from 'no NIV-indication yet' patients with ALS. Currently used cut-off values might be adjusted and other respiratory function tests such as SNIP and PCF may become part of routine care in patients with ALS in order to avoid non-timely initiation of (non-invasive) ventilation.

  6. Extension of the Contingency Naming Test to adult assessment: psychometric analysis in a college student sample.

    PubMed

    Riddle, Tara; Suhr, Julie

    2012-01-01

    The Contingency Naming Test (CNT; Taylor, Albo, Phebus, Sachs, & Bierl, 1987) was initially designed to assess aspects of executive functioning, such as processing speed and response inhibition, in children. The measure has shown initial utility in identifying differences in executive function among child clinical groups; however, there is an absence of adequate psychometric data for use with adults. The current study expanded psychometric data upward for use with a college student sample and explored the measure's test-retest reliability and factor structure. Performance in the adult sample showed continued improvement above child norms, consistent with theories of executive function development. Exploratory factor analysis showed that the CNT is most closely related to measures of processing speed, as well as elements of response inhibition within the latter trials. Overall, results from the current study provide added support for the utility of the CNT as a measure of executive functioning in young adults. However, more research is needed to determine patterns of performance among adult clinical groups, as well as to better understand how performance patterns may change in a broader age range, including middle and older adulthood.

  7. Remembering operations.

    PubMed

    Kolers, P A

    1973-09-01

    Two commonplace assumptions about encoding are that sentences are encoded and recognized on the basis of their semantic features primarily and that information regarding form features such as typography is typically ignored or discarded. These assumptions were tested m the present experiment where, within a signal-detection paradigm, S sorted sentences according to whether he had seen them before or not (old vs new) and, if they were old, whether their reappearance was in the same typography as on the first occurrence or a different one. Of the two typographies, one was familiar and the other unfamiliar. Results show that a considerable amount of information regarding surface features is stored for many minutes and that ease of initial encoding is inversely related to likelihood of subsequent recognition: sentences in the unfamiliar typography were remembered better. The results are probably not due to time spent encoding; control tests suggest that time spent encoding a difficult typography does not by itself increase recognition of the semantic content embodied in the typography. Other control tests show that pictorial features or images of the sentences play no significant role in their subsequent recognition. One interpretation of the results is that the analytic activities or cognitive operations that characterize initial acquisition play a significant role in subsequent recognition.

  8. NET-VISA, a Bayesian method next-generation automatic association software. Latest developments and operational assessment.

    NASA Astrophysics Data System (ADS)

    Le Bras, Ronan; Kushida, Noriyuki; Mialle, Pierrick; Tomuta, Elena; Arora, Nimar

    2017-04-01

    The Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) has been developing a Bayesian method and software to perform the key step of automatic association of seismological, hydroacoustic, and infrasound (SHI) parametric data. In our preliminary testing in the CTBTO, NET_VISA shows much better performance than its currently operating automatic association module, with a rate for automatic events matching the analyst-reviewed events increased by 10%, signifying that the percentage of missed events is lowered by 40%. Initial tests involving analysts also showed that the new software will complete the automatic bulletins of the CTBTO by adding previously missed events. Because products by the CTBTO are also widely distributed to its member States as well as throughout the seismological community, the introduction of a new technology must be carried out carefully, and the first step of operational integration is to first use NET-VISA results within the interactive analysts' software so that the analysts can check the robustness of the Bayesian approach. We report on the latest results both on the progress for automatic processing and for the initial introduction of NET-VISA results in the analyst review process

  9. Test Report for NG Sensors GTX-1000

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manginell, Ronald P.

    2014-12-01

    This report describes initial testing of the NG Sensor GTX-1000 natural gas monitoring system. This testing showed that the retention time, peak area stability and heating value repeatability of the GTX-1000 were promising for natural gas measurements in the field or at the well head. The repeatability can be less than 0.25% for LHV and HHV for the Airgas standard tested in this report, which is very promising for a first generation prototype. Ultimately this system should be capable of 0.1% repeatability in heating value at significant size and power reductions compared with competing systems.

  10. DANTi: Detect and Avoid iN The Cockpit

    NASA Technical Reports Server (NTRS)

    Chamberlain, James; Consiglio, Maria; Munoz, Cesar

    2017-01-01

    Mid-air collision risk continues to be a concern for manned aircraft operations, especially near busy non-towered airports. The use of Detect and Avoid (DAA) technologies and draft standards developed for unmanned aircraft systems (UAS), either alone or in combination with other collision avoidance technologies, may be useful in mitigating this collision risk for manned aircraft. This paper describes a NASA research effort known as DANTi (DAA iN The Cockpit), including the initial development of the concept of use, a software prototype, and results from initial flight tests conducted with this prototype. The prototype used a single Automatic Dependent Surveillance - Broadcast (ADS-B) traffic sensor and the own aircraft's position, track, heading and air data information, along with NASA-developed DAA software to display traffic alerts and maneuver guidance to manned aircraft pilots on a portable tablet device. Initial flight tests with the prototype showed a successful DANTi proof-of-concept, but also demonstrated that the traffic separation parameter set specified in the RTCA SC-228 Phase I DAA MOPS may generate excessive false alerts during traffic pattern operations. Several parameter sets with smaller separation values were also tested in flight, one of which yielded more timely alerts for the maneuvers tested. Results from this study may further inform future DANTi efforts as well as Phase II DAA MOPS development.

  11. Reentry Motion and Aerodynamics of the MUSES-C Sample Return Capsule

    NASA Astrophysics Data System (ADS)

    Ishii, Nobuaki; Yamada, Tetsuya; Hiraki, Koju; Inatani, Yoshifumi

    The Hayabusa spacecraft (MUSES-C) carries a small capsule for bringing asteroid samples back to the earth. The initial spin rate of the reentry capsule together with the flight path angle of the reentry trajectory is a key parameter for the aerodynamic motion during the reentry flight. The initial spin rate is given by the spin-release mechanism attached between the capsule and the mother spacecraft, and the flight path angle can be modified by adjusting the earth approach orbit. To determine the desired values of both parameters, the attitude motion during atmospheric flight must be clarified, and angles of attack at the maximum dynamic pressure and the parachute deployment must be assessed. In previous studies, to characterize the aerodynamic effects of the reentry capsule, several wind-tunnel tests were conducted using the ISAS high-speed flow test facilities. In addition to the ground test data, the aerodynamic properties in hypersonic flows were analyzed numerically. Moreover, these data were made more accurate using the results of balloon drop tests. This paper summarized the aerodynamic properties of the reentry capsule and simulates the attitude motion of the full-configuration capsule during atmospheric flight in three dimensions with six degrees of freedom. The results show the best conditions for the initial spin rates and flight path angles of the reentry trajectory.

  12. 40 CFR 63.2261 - By what date must I conduct performance tests or other initial compliance demonstrations?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... tests upon initial startup or no later than 180 calendar days after the compliance date that is... conduct initial compliance demonstrations that do not require performance tests upon initial startup or no...

  13. 40 CFR 75.20 - Initial certification and recertification procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... all applicable initial certification tests under paragraph (c) of this section are completed by the... installed, initial certification is required. (1) Notification of initial certification test dates. The...) tests. (4) Certification (or recertification) application formal approval process. The Administrator...

  14. 40 CFR 75.20 - Initial certification and recertification procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... all applicable initial certification tests under paragraph (c) of this section are completed by the... installed, initial certification is required. (1) Notification of initial certification test dates. The...) tests. (4) Certification (or recertification) application formal approval process. The Administrator...

  15. 40 CFR 75.20 - Initial certification and recertification procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... all applicable initial certification tests under paragraph (c) of this section are completed by the... installed, initial certification is required. (1) Notification of initial certification test dates. The...) tests. (4) Certification (or recertification) application formal approval process. The Administrator...

  16. Magnesium release from mesoporous carriers on endosseus implants does not influence bone maturation at 6 weeks in rabbit bone.

    PubMed

    Galli, Silvia; Andersson, Martin; Jinno, Yohei; Karlsson, Johan; He, Wenxiao; Xue, Ying; Mustafa, Kamal; Wennerberg, Ann; Jimbo, Ryo

    2017-10-01

    The release of magnesium ions (Mg 2+ ) from titanium surfaces has been shown to boost the initial biological response of peri-implant bone and to increase the biomechanical strength of osseointegration. The objective of the present paper was to investigate if the initial improvement in osseointegration would influence the bone remodeling also during the maturation stage of bone healing. Titanium implants were coated with mesoporous titania layers and either loaded with Mg 2+ (test group) or left untreated (control group). The implants were inserted in the tibiae of 10 New Zealand White rabbits. Osseointegration was assessed after 6 weeks by means of biomechanical testing (RTQ), non-decalcified histology and histomorphometry (BIC%, BA%, NBA%). The expression of genes involved in the bone formation and remodeling was quantified using qPCR. Mg 2+ releasing mesoporous titania coatings showed, on average, higher removal torques and histomorphometrical outcomes (RTQ: 17.2 Ncm vs. 15 Ncm; BIC: 38.8% vs. 32.1%; BA%: 71.6% vs. 64%; NBA% 62.5% vs. 54% for the tests vs the controls); however, the differences were not statistically significant. Three osteogenic markers, osteocalcin (OC), collagen 1 alpha 1 (COL1A1), and alkalin phosphatase (ALPL), were respectively 2-fold, 1.53-fold, and 1.13-fold up-regulated in the control group compared to the test. The expression of COL1A1 was particularly high in both groups, while the biomarkers for remodeling and inflammation showed a low expression in both groups. The results suggested that the initial enhancement in osseointegration induced by magnesium release from mesoporous titania coatings has no detrimental effects during bone maturation. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2118-2125, 2017. © 2016 Wiley Periodicals, Inc.

  17. Advanced Gas Turbine (AGT) powertrain system

    NASA Technical Reports Server (NTRS)

    Helms, H. E.; Kaufeld, J.; Kordes, R.

    1981-01-01

    A 74.5 kW(100 hp) advanced automotive gas turbine engine is described. A design iteration to improve the weight and production cost associated with the original concept is discussed. Major rig tests included 15 hours of compressor testing to 80% design speed and the results are presented. Approximately 150 hours of cold flow testing showed duct loss to be less than the design goal. Combustor test results are presented for initial checkout tests. Turbine design and rig fabrication is discussed. From a materials study of six methods to fabricate rotors, two have been selected for further effort. A discussion of all six methods is given.

  18. A Size Effect on the Fatigue Crack Growth Rate Threshold of Alloy 718

    NASA Technical Reports Server (NTRS)

    Garr, K. R.; Hresko, G. C., III

    1998-01-01

    Fatigue crack growth rate (FCGR) tests were conducted on Alloy 718 in the solution annealed and aged condition at room temperature. In each test, the FCGR threshold was measured using the decreasing (Delta)K method. Initial testing was at two facilities, one of which used C(T) specimens with W = 127 mm. Previous data at the other facility had been obtained with specimens with W = 50.8 mm. A comparison of test results at R = 0.1 showed that the threshold for the 127 mm specimen was considerably higher than that of the 50.8 mm specimen. A check showed that this difference was not due to a heat-to-heat or lab-to-lab variation. Additional tests were conducted on specimens with W = 25.4 mm and at other R values. Data for the various specimens is presented along with parameters usually used to describe threshold behavior.

  19. Update on results of SPRE testing at NASA Lewis

    NASA Technical Reports Server (NTRS)

    Cairelli, James E.; Swec, Diane M.; Wong, Wayne A.; Doeberling, Thomas J.; Madi, Frank J.

    1991-01-01

    The Space Power Research Engine (SPRE), a free-piston Stirling engine with a linear alternator, is being tested at NASA Lewis Research Center as part of the Civilian Space Technology Initiative (CSTI) as a candidate for high capacity space power. Results are presented from recent SPRE tests designed to investigated the effects of variation in the displacer seal clearance and piston centering port area on engine performance and dynamics. The impact of these variations on PV power and efficiency are presented. Comparisons of the displacer seal clearance tests results with HFAST code predictions show good agreement for PV power, but show poor agreement for PV efficiency. Correlations are presented relating the piston midstroke position to the dynamic Delta P across the piston and the centering port area. Test results indicate that a modest improvement in PV power and efficiency may be realized with a reduction in piston centering port area.

  20. AUU-to-AUG mutation in the initiator codon of the translation initiation factor IF3 abolishes translational autocontrol of its own gene (infC) in vivo.

    PubMed Central

    Butler, J S; Springer, M; Grunberg-Manago, M

    1987-01-01

    We previously showed that Escherichia coli translation initiation factor IF3 regulates the expression of its own gene infC at the translational level in vivo. Here we create two alterations in the infC gene and test their effects on translational autocontrol of infC expression in vivo by measuring beta-galactosidase activity expressed from infC-lacZ gene fusions under conditions of up to 4-fold derepression or 3-fold repression of infC expression. Replacement of the infC promoter with the trp promoter deletes 120 nucleotides of the infC mRNA 5' to the translation initiation site without affecting autogenous translational control. Mutation of the unusual AUU initiator codon of infC to the more common AUG initiator codon abolishes translation initiation factor IF3-dependent repression and derepression of infC expression in vivo. These results establish the AUU initiator codon of infC as an essential cis-acting element in autogenous translational control of translation initiation factor IF3 expression in vivo. PMID:2954162

  1. AUU-to-AUG mutation in the initiator codon of the translation initiation factor IF3 abolishes translational autocontrol of its own gene (infC) in vivo.

    PubMed

    Butler, J S; Springer, M; Grunberg-Manago, M

    1987-06-01

    We previously showed that Escherichia coli translation initiation factor IF3 regulates the expression of its own gene infC at the translational level in vivo. Here we create two alterations in the infC gene and test their effects on translational autocontrol of infC expression in vivo by measuring beta-galactosidase activity expressed from infC-lacZ gene fusions under conditions of up to 4-fold derepression or 3-fold repression of infC expression. Replacement of the infC promoter with the trp promoter deletes 120 nucleotides of the infC mRNA 5' to the translation initiation site without affecting autogenous translational control. Mutation of the unusual AUU initiator codon of infC to the more common AUG initiator codon abolishes translation initiation factor IF3-dependent repression and derepression of infC expression in vivo. These results establish the AUU initiator codon of infC as an essential cis-acting element in autogenous translational control of translation initiation factor IF3 expression in vivo.

  2. Air Force Officer Qualifying Test Form T: Initial Item-, Test-, Factor-, and Composite-Level Analyses

    DTIC Science & Technology

    2016-12-01

    five lower-order factors representing verbal, math , spatial, perceptual speed, and aviation knowledge, and a hierarchical general factor showed the...Academic Aptitude Verbal Quant. Verbal Analogies 25 X X X Arithmetic Reasoning 25 X X Word Knowledge 25 X X X Math Knowledge 25 X X...Reasoning (AR) uses word problems to assess the ability to understand arithmetic relations. Math Knowledge (MK) assesses the ability to use

  3. Mandibular Advancing Positive Pressure Apnea Remediation Device (MAPPARD)

    DTIC Science & Technology

    2014-06-01

    inlet valve that will accept a 90-degree swivel and is tapered in the area where the lips intersect for better comfort . Further ergonomic testing will...production also informed the size of the necessary mouthpiece and the requirement for a design for a more ergonomic airway mouthpiece and tube connection...fit and ergonomics (see Figures. 32 and 33). The subsequent initial test showed that the model was comfortable and without aid of continuous air

  4. Association Between Direct-to-Consumer Advertising and Testosterone Testing and Initiation in the United States, 2009-2013.

    PubMed

    Layton, J Bradley; Kim, Yoonsang; Alexander, G Caleb; Emery, Sherry L

    2017-03-21

    Testosterone initiation increased substantially in the United States from 2000 to 2013, especially among men without clear indications. Direct-to-consumer advertising (DTCA) also increased during this time. To investigate associations between televised DTCA and testosterone testing and initiation in the United States. Ecologic study conducted in designated market areas (DMAs) in the United States. Monthly testosterone advertising ratings were linked to DMA-level testosterone use data from 2009-2013 derived from commercial insurance claims. Associations between DTCA and testosterone testing, initiation, and initiation without recent baseline tests were estimated using Poisson generalized estimating equations. Monthly Nielsen ratings for testosterone DTCA in the 75 largest DMAs. (1) Rates of new serum testosterone testing; (2) rates of testosterone initiation (in-office injection, surgical implant, or pharmacy dispensing) for all testosterone products combined and for specific brands; and (3) rates of testosterone initiation without recent serum testosterone testing. Of 17 228 599 commercially insured men in the 75 DMAs, 1 007 990 (mean age, 49.6 [SD, 11.5] years) had new serum testosterone tests and 283 317 (mean age, 51.8 [SD, 11.3] years) initiated testosterone treatment. Advertising intensity varied by geographic region and time, with the highest intensity seen in the southeastern United States and with months ranging from no ad exposures to a mean of 13.6 exposures per household. Nonbranded advertisements were common prior to 2012, with branded advertisements becoming more common during and after 2012. Each household advertisement exposure was associated with a monthly increase in rates of new testosterone testing (rate ratio [RR], 1.006; 95% CI, 1.004-1.008), initiation (RR, 1.007; 95% CI, 1.004-1.010), and initiation without a recent test (RR, 1.008; 95% CI, 1.002-1.013). Mean absolute rate increases were 0.14 tests (95% CI, 0.09-0.19), 0.05 new initiations (95% CI, 0.03-0.08), and 0.02 initiations without a recent test (95% CI, 0.01-0.03) per 10 000 men for each monthly ad exposure over the entire period. Among US men residing in the 75 designated market areas, regional exposure to televised direct-to-consumer advertising was associated with greater testosterone testing, new initiation, and initiation without recent testing.

  5. Initial Experience with Balloon-Occluded Trans-catheter Arterial Chemoembolization (B-TACE) for Hepatocellular Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maruyama, Mitsunari, E-mail: mitunari@med-shimane.u.ac.jp; Yoshizako, Takeshi, E-mail: yosizako@med.shimane-u.ac.jp; Nakamura, Tomonori, E-mail: t-naka@med.shimane-u.ac.jp

    2016-03-15

    PurposeThis study was performed to evaluate the accumulation of lipiodol emulsion (LE) and adverse events during our initial experience of balloon-occluded trans-catheter arterial chemoembolization (B-TACE) for hepatocellular carcinoma (HCC) compared with conventional TACE (C-TACE).MethodsB-TACE group (50 cases) was compared with C-TACE group (50 cases). The ratio of the LE concentration in the tumor to that in the surrounding embolized liver parenchyma (LE ratio) was calculated after each treatment. Adverse events were evaluated according to the Common Terminology Criteria for Adverse Effects (CTCAE) version 4.0.ResultsThe LE ratio at the level of subsegmental showed a statistically significant difference between the groups (tmore » test: P < 0.05). Only elevation of alanine aminotransferase was more frequent in the B-TACE group, showing a statistically significant difference (Mann–Whitney test: P < 0.05). While B-TACE caused severe adverse events (liver abscess and infarction) in patients with bile duct dilatation, there was no statistically significant difference in incidence between the groups. Multivariate logistic regression analysis suggested that the significant risk factor for liver abscess/infarction was bile duct dilatation (P < 0.05).ConclusionThe LE ratio at the level of subsegmental showed a statistically significant difference between the groups (t test: P < 0.05). B-TACE caused severe adverse events (liver abscess and infarction) in patients with bile duct dilatation.« less

  6. Biocompatibility and setting time of CPM-MTA and white Portland cement clinker with or without calcium sulfate.

    PubMed

    Bramante, Clovis Monteiro; Kato, Marcia Magro; Assis, Gerson Francisco de; Duarte, Marco Antonio Hungaro; Bernardineli, Norberti; Moraes, Ivaldo Gomes de; Garcia, Roberto Brandão; Ordinola-Zapata, Ronald; Bramante, Alexandre Silva

    2013-01-01

    To evaluate the biocompatibility and the setting time of Portland cement clinker with or without 2% or 5% calcium sulfate and MTA-CPM. Twenty-four mice (Rattus norvegicus) received subcutaneously polyethylene tubes filled with Portland cement clinker with or without 2% or 5% calcium sulfate and MTA. After 15, 30 and 60 days of implantation, the animals were killed and specimens were prepared for microscopic analysis. For evaluation of the setting time, each material was analyzed using Gilmore needles weighing 113.5 g and 456.5 g, according to the ASTM specification Number C266-08 guideline. Data were analyzed by ANOVA and Tukey's test for setting time and Kruskal-Wallis and Dunn test for biocompatibility at 5% significance level. Histologic observation showed no statistically significant difference of biocompatibility (p>0.05) among the materials in the subcutaneous tissues. For the setting time, clinker without calcium sulfate showed the shortest initial and final setting times (6.18 s/21.48 s), followed by clinker with 2% calcium sulfate (9.22 s/25.33 s), clinker with 5% calcium sulfate (10.06 s/42.46 s) and MTA (15.01 s/42.46 s). All the tested materials showed biocompatibility and the calcium sulfate absence shortened the initial and final setting times of the white Portland cement clinker.

  7. Reduction of the pace polarization artefact for capture detection applications by a tri-phasic stimulation pulse.

    PubMed

    Sutton, R; Fröhlig, G; de Voogt, W G; Goethals, M; Hintringer, F; Kennergren, C; Scanu, P; Guilleman, D; Treese, N; Hartung, W M; Stammwitz, E; Muetstege, A

    2004-11-01

    This study investigated the ability to minimize pace polarization artefacts (PPA) by adjusting the post-stimulus pulse duration of a tri-phasic stimulation pulse. Adjustment of the stimulation pulse was enabled by downloading special study software into an already implanted pacemaker. Tests were performed in a total of 296 atrial leads and 311 ventricular leads. Both chronic and acute leads were included in the study. Statistically significant differences were found in the initial PPA (without any adjustment of the stimulus pulse) between atrial and ventricular leads. In addition, significant differences were observed among various lead models with respect to changes over time in the initial ventricular PPA. Successful PPA reduction was defined as a reduction of the PPA below 0.5 mV for atrial leads and below 1 mV for ventricular leads. Results show a success rate for ventricular and atrial PPA reduction of 97.8% and 98.7%, respectively. Threshold tests showed that after reduction of the PPA loss of ventricular capture can be reliably detected. However, atrial threshold tests showed many false positive evoked response detections. In addition, unexpectedly high evoked response amplitudes were observed in the atrium after reduction of the PPA. Results from additional measurements suggest that these high atrial evoked response amplitudes come from the influence of the input filter of the pacemaker.

  8. Effect of sample initial magnetic field on the metal magnetic memory NDT result

    NASA Astrophysics Data System (ADS)

    Moonesan, Mahdi; Kashefi, Mehrdad

    2018-08-01

    One of the major concerns regarding the use of Metal Magnetic Memory (MMM) technique is the complexity of residual magnetization effect on output signals. The present study investigates the influence of residual magnetic field on stress induced magnetization. To this end, various initial magnetic fields were induced on a low carbon steel sample, and for each level of residual magnetic field, the sample was subjected to a set of 4-point bending tests and, their corresponding MMM signals were collected from the surface of the bended sample using a tailored metal magnetic memory scanning device. Results showed a strong correlation between sample residual magnetic field and its corresponding level of stress induced magnetic field. It was observed that the sample magnetic field increases with applying the bending stress as long as the initial residual magnet field is low (i.e. <117 mG), but starts decreasing with higher levels of initial residual magnetic fields. Besides, effect of bending stress on the MMM output of a notched sample was investigated. The result, again, showed that MMM signals exhibit a drop at stress concentration zone when sample has high level of initial residual magnetic field.

  9. Principles of proportional recovery after stroke generalize to neglect and aphasia.

    PubMed

    Marchi, N A; Ptak, R; Di Pietro, M; Schnider, A; Guggisberg, A G

    2017-08-01

    Motor recovery after stroke can be characterized into two different patterns. A majority of patients recover about 70% of initial impairment, whereas some patients with severe initial deficits show little or no improvement. Here, we investigated whether recovery from visuospatial neglect and aphasia is also separated into two different groups and whether similar proportions of recovery can be expected for the two cognitive functions. We assessed 35 patients with neglect and 14 patients with aphasia at 3 weeks and 3 months after stroke using standardized tests. Recovery patterns were classified with hierarchical clustering and the proportion of recovery was estimated from initial impairment using a linear regression analysis. Patients were reliably clustered into two different groups. For patients in the first cluster (n = 40), recovery followed a linear model where improvement was proportional to initial impairment and achieved 71% of maximal possible recovery for both cognitive deficits. Patients in the second cluster (n = 9) exhibited poor recovery (<25% of initial impairment). Our findings indicate that improvement from neglect or aphasia after stroke shows the same dichotomy and proportionality as observed in motor recovery. This is suggestive of common underlying principles of plasticity, which apply to motor and cognitive functions. © 2017 EAN.

  10. Hysteresis in simulations of malaria transmission

    NASA Astrophysics Data System (ADS)

    Yamana, Teresa K.; Qiu, Xin; Eltahir, Elfatih A. B.

    2017-10-01

    Malaria transmission is a complex system and in many parts of the world is closely related to climate conditions. However, studies on environmental determinants of malaria generally consider only concurrent climate conditions and ignore the historical or initial conditions of the system. Here, we demonstrate the concept of hysteresis in malaria transmission, defined as non-uniqueness of the relationship between malaria prevalence and concurrent climate conditions. We show the dependence of simulated malaria transmission on initial prevalence and the initial level of human immunity in the population. Using realistic time series of environmental variables, we quantify the effect of hysteresis in a modeled population. In a set of numerical experiments using HYDREMATS, a field-tested mechanistic model of malaria transmission, the simulated maximum malaria prevalence depends on both the initial prevalence and the initial level of human immunity in the population. We found the effects of initial conditions to be of comparable magnitude to the effects of interannual variability in environmental conditions in determining malaria prevalence. The memory associated with this hysteresis effect is longer in high transmission settings than in low transmission settings. Our results show that efforts to simulate and forecast malaria transmission must consider the exposure history of a location as well as the concurrent environmental drivers.

  11. Dynamic Fracture Properties of Rocks Subjected to Static Pre-load Using Notched Semi-circular Bend Method

    NASA Astrophysics Data System (ADS)

    Chen, Rong; Li, Kang; Xia, Kaiwen; Lin, Yuliang; Yao, Wei; Lu, Fangyun

    2016-10-01

    A dynamic load superposed on a static pre-load is a key problem in deep underground rock engineering projects. Based on a modified split Hopkinson pressure bar test system, the notched semi-circular bend (NSCB) method is selected to investigate the fracture initiation toughness of rocks subjected to pre-load. In this study, a two-dimensional ANSYS finite element simulation model is developed to calculate the dimensionless stress intensity factor. Three groups of NSCB specimen are tested under a pre-load of 0, 37 and 74 % of the maximum static load and with the loading rate ranging from 0 to 60 GPa m1/2 s-1. The results show that under a given pre-load, the fracture initiation toughness of rock increases with the loading rate, resembling the typical rate dependence of materials. Furthermore, the dynamic rock fracture toughness decreases with the static pre-load at a given loading rate. The total fracture toughness, defined as the sum of the dynamic fracture toughness and initial stress intensity factor calculated from the pre-load, increases with the pre-load at a given loading rate. An empirical equation is used to represent the effect of loading rate and pre-load force, and the results show that this equation can depict the trend of the experimental data.

  12. The unintended consequences of cervical screening: distress in women undergoing cytologic surveillance.

    PubMed

    Sharp, Linda; Cotton, Seonaidh; Cruickshank, Margaret; Gray, Nicola M; Harrild, Kirsten; Smart, Louise; Walker, Leslie G; Little, Julian

    2014-04-01

    It is well known that receipt of an initial abnormal cervical cytology test can trigger considerable anxiety among women. Less is known about the impact of follow-up by repeat cytology tests. We quantified prevalence, and identified predictors, of distress after repeat cytologic testing in women with a single low-grade test. Within the framework of the TOMBOLA randomized controlled trial of alternative managements, 844 women aged 20 to 59 years with a single routine cytology test showing borderline nuclear abnormalities (BNA; broadly equivalent to atypical squamous cells of undetermined significance) were assigned to follow-up by repeat cytology in primary care (the first test was due 6 months after the initial BNA result). Women completed sociodemographic and psychosocial questionnaires at recruitment and the Impact of Event Scale (IES) 6 weeks after their first follow-up cytology test. Factors associated with significant psychologic distress (IES ≥ 9) were identified using logistic regression. The response rate was 74% (n = 621/844). Of all the respondents, 39% scored in the range for significant distress. Distress varied by follow-up cytology result: negative, 36%; BNA or mild dyskaryosis, 42%; other (including high grade and inadequate), 55%. After adjusting for the cytology result, risk of distress was significantly raised in women who had significant anxiety at recruitment, reported experiencing pain after the follow-up cytology, had children, or were dissatisfied with support they had received after their initial BNA test. Substantial proportions of women experience surveillance-related psychologic distress after a follow-up cytology test, even when the result is negative. This is an important, albeit unintended, consequence of cervical screening. Strategies to alleviate this distress merit attention.

  13. Terahertz NDE of Stressed Composite Overwrapped Pressure Vessels - Initial Testing

    NASA Technical Reports Server (NTRS)

    Madaras, Eric I.; Seebo, Jeffrey P.; Anatasi, Robert F.

    2009-01-01

    Terahertz radiation nondestructive evaluation was applied to a set of Kevlar composite overwrapped pressure vessel bottles that had undergone a series of thermal and pressure tests to simulate stress rupture effects. The bottles in these nondestructive evaluation tests were bottles that had not ruptured but had survived various times at the elevated load and temperature levels. Some of the bottles showed evidence of minor composite failures. The terahertz radiation did detect visible surface flaws, but did not detect any internal chemical or material degradation of the thin overwraps.

  14. Response Modeling of Lightweight Charring Ablators and Thermal Radiation Testing Results

    NASA Technical Reports Server (NTRS)

    Congdon, William M.; Curry, Donald M.; Rarick, Douglas A.; Collins, Timothy J.

    2003-01-01

    Under NASA's In-Space Propulsion/Aerocapture Program, ARA conducted arc-jet and thermal-radiation ablation test series in 2003 for advanced development, characterization, and response modeling of SRAM-20, SRAM-17, SRAM-14, and PhenCarb-20 ablators. Testing was focused on the future Titan Explorer mission. Convective heating rates (CW) were as high as 153 W/sq cm in the IHF and radiation rates were 100 W/sq cm in the Solar Tower Facility. The ablators showed good performance in the radiation environment without spallation, which was initially a concern, but they also showed higher in-depth temperatures when compared to analytical predictions based on arc-jet thermal-ablation response models. More testing in 2003 is planned in both of these facility to generate a sufficient data base for Titan TPS engineering.

  15. An ERP study on initial second language vocabulary learning.

    PubMed

    Yum, Yen Na; Midgley, Katherine J; Holcomb, Phillip J; Grainger, Jonathan

    2014-04-01

    This study examined the very initial phases of orthographic and semantic acquisition in monolingual native English speakers learning Chinese words under controlled laboratory conditions. Participants engaged in 10 sessions of vocabulary learning, four of which were used to obtain ERPs. Performance in behavioral tests improved over sessions, and these data were used to define fast and slow learners. Most important is that ERPs in the two groups of learners revealed qualitatively distinct learning patterns. Only fast learners showed a left-lateralized increase in N170 amplitude with training. Furthermore, only fast learners showed an increased N400 amplitude with training, with a distinct anterior distribution. Slow learners, on the other hand, showed a posterior positive effect, with increasingly positive-going waveforms in occipital sites as training progressed. Possible mechanisms underlying these qualitative differences are discussed. Copyright © 2014 Society for Psychophysiological Research.

  16. [Tuberculous gumma or metastatic tuberculous abscess as initial diagnosis of tuberculosis in an immunocompetent patient: an unusual presentation].

    PubMed

    Marco, A; Solé, R; Raguer, E; Aranda, M

    2014-01-01

    Tuberculous cold abscesses or gumma are an unusual form of tuberculosis. We report a case of gumma as initial diagnosis of disseminated tuberculosis. This case was studied in 2012 in Barcelona ( Spain). Source data was compiled from the electronic clinical records, hospital reports and additional diagnostic testing. Immunocompetent inmate, born in Cape Verde, living in Spain since the age of four. Positive tuberculin skin test. Initial examination without interest, but a palpable mass in lower back. Fine needle aspiration of the abscess was positive (PCR and Lowenstein) for M. tuberculosis. Computed tomography showed lung cavitary nodes in apical part and lung upper right side. After respiratory isolation, antituberculous therapy and an excellent evolution, the patient was discharged from hospital with disseminated tuberculosis diagnosis. It is advisable to monitor the injuries since, although rare, it may be secondary to Mycobacterium tuberculosis infection, mainly in inmuno-compromised populations and in immigrants coming from hyper-endemic tuberculosis areas.

  17. A novel orthoimage mosaic method using a weighted A∗ algorithm - Implementation and evaluation

    NASA Astrophysics Data System (ADS)

    Zheng, Maoteng; Xiong, Xiaodong; Zhu, Junfeng

    2018-04-01

    The implementation and evaluation of a weighted A∗ algorithm for orthoimage mosaic with UAV (Unmanned Aircraft Vehicle) imagery is proposed. The initial seam-line network is firstly generated by standard Voronoi Diagram algorithm; an edge diagram is generated based on DSM (Digital Surface Model) data; the vertices (conjunction nodes of seam-lines) of the initial network are relocated if they are on high objects (buildings, trees and other artificial structures); and the initial seam-lines are refined using the weighted A∗ algorithm based on the edge diagram and the relocated vertices. Our method was tested with three real UAV datasets. Two quantitative terms are introduced to evaluate the results of the proposed method. Preliminary results show that the method is suitable for regular and irregular aligned UAV images for most terrain types (flat or mountainous areas), and is better than the state-of-the-art method in both quality and efficiency based on the test datasets.

  18. Factors influencing participation in colorectal cancer screening programs in Spain.

    PubMed

    Vanaclocha-Espi, Mercedes; Ibáñez, Josefa; Molina-Barceló, Ana; Pérez, Elena; Nolasco, Andreu; Font, Rebeca; Pérez-Riquelme, Francisco; de la Vega, Mariola; Arana-Arri, Eunate; Oceja, MªElena; Espinàs, Josep Alfons; Portillo, Isabel; Salas, Dolores

    2017-12-01

    To analyze the sociodemographic and organizational factors influencing participation in population-based colorectal cancer screening programs (CRCSP) in Spain, a retrospective study was conducted in a cohort of people invited to participate in the first 3 screening rounds of 6 CRCSP from 2000 to 2012. Mixed logistic regression models were used to analyze the relationship between sociodemographic and organizational factors, such as the type of fecal occult blood test (FOBT) used and the FOBT delivery type. The analysis was performed separately in groups (Initial screening-first invitation, Subsequent invitation for previous never-responders, Subsequent invitation-regular, Subsequent invitation-irregular intervals). The results showed that, in the Initial screening-first invitation group, participation was higher in women than in men in all age groups (OR 1.05 in persons aged 50-59years and OR 1.12 in those aged 60-69years). Participation was also higher when no action was required to receive the FOBT kit, independently of the type of screening (Initial screening-first invitation [OR 2.24], Subsequent invitation for previous never-responders [OR 2.14], Subsequent invitation-regular [OR 2.03], Subsequent invitation-irregular intervals [OR 9.38]) and when quantitative rather than qualitative immunological FOBT (FIT) was offered (Initial screening-first invitation [OR 0.70], Subsequent invitation for previous never-responders [OR 0.12], Subsequent invitation-regular [OR 0.20]) or guaiac testing (Initial screening-first invitation [OR 0.81], Subsequent invitation for previous never-responders [OR 0.88], Subsequent invitation-regular [OR 0.73]). In conclusion, the results of this study show that screening participation could be enhanced by inclusion of the FOBT kit with the screening invitation and the use of the quantitative FIT. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Degradation of bisphenol A in water by the heterogeneous photo-Fenton.

    PubMed

    Jiang, Chuanrui; Xu, Zhencheng; Guo, Qingwei; Zhuo, Qiongfang

    2014-01-01

    Bisphenol A (BPA) is a kind of a controversial endocrine disruptor, and is ubiquitous in environment. The degradation of BPA with the heterogeneous photo-Fenton system was demonstrated in this study. The Fe-Y molecular sieve catalyst was prepared with the ion exchange method, and it was characterized by X-ray radiation diffraction (XRD). The effects ofpH, initial concentration of H2O2, initial BPA concentration, and irradiation intensity on the degradation of BPA were investigated. The service life and iron solubility of catalyst were also tested. XRD test shows that the major phase of the Fe-Y catalyst was Fe2O3. The method of heterogeneous photo-Fenton with Fe-Y catalyst was superior to photolysis, photo-oxidation with only hydrogen, heterogeneous Fenton, and homogeneous photo-Fenton approaches. pH value had no obvious effects on BPA degradation over the range of 2.2-7.2. The initial concentration of H2O2 had an optimal value of 20 x 10(-4) mol/L. The decrease in initial concentration of BPA was favourable for degradation. The intensity of ultraviolet irradiation has no obvious effect on the BPA removal. The stability tests indicated that the Fe-Y catalyst can be reused and iron solubility concentration ranged from NA to 0.0062 mg/L. Based on the results, the heterogeneous photo-Fenton treatment is the available method for the degradation of BPA.

  20. High-Throughput Testing of Novel-Novel Combination Therapies for Cancer: An Idea Whose Time Has Come.

    PubMed

    Scarlett, Uciane K; Chang, Dennis C; Murtagh, Thomas J; Flaherty, Keith T

    2016-09-01

    Combination therapies are essential to address the genetic complexity, plasticity, and heterogeneity of tumors and to overcome resistance mechanisms that confound single-agent approaches, and are a paradigm that became well established in the era of conventional cytotoxic chemotherapies. Today, we are well equipped to address many of the scientific, clinical, and collaboration challenges that have existed historically; however, the pace of testing rational combinations is modest. Our analysis shows that the volume of clinical trials testing multiple investigational pipeline agents ("novel-novel" combinations) is dismally low, as out of approximately 1,500 phase I to III investigational combination trials initiated in 2014-2015, only 80 were for novel-novel combinations, and only 9 of those involved more than one company. The Collaborative Novel-Novel Combination Therapies (CoNNCT) initiative aims to alleviate this bottleneck by developing a new, faster paradigm for early investigation of scientifically informed, novel-novel drug combinations. The initiative kicked off on March 7, 2016, when representatives from top academic centers, biopharma, nonprofits, the FDA, and other groups gathered to define an actionable path forward. Cancer Discov; 6(9); 956-62. ©2016 AACR. ©2016 American Association for Cancer Research.

  1. ENVIROMENTALLY BENIGN MITIGATION OF MICROBIOLOGICALLY INFLUENCED CORROSION (MIC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Robert Paterek; Gemma Husmillo; Amrutha Daram

    The overall program objective is to develop and evaluate environmentally benign agents or products that are effective in the prevention, inhibition, and mitigation of microbially influenced corrosion (MIC) in the internal surfaces of metallic natural gas pipelines. The goal is to develop one or more environmentally benign (a.k.a. ''green'') products that can be applied to maintain the structure and dependability of the natural gas infrastructure. The technical approach for this quarter includes the application of the method of fractionation of the extracts by high performance liquid chromatography (HPLC); determination of antimicrobial activities of the new extracts and fractions using amore » growth inhibition assay, and evaluation of the extracts' ability to inhibit biofilm formation. We initiated the delivery system for these new biocides in the test cell and in mixtures of foam components and biocides/anti-biofilms. A total of 51 fractions collected by HPLC from crude extracts that were obtained from three varieties of Capsicum sp. (Serrano, Habanero, Chile de Arbol) were subjected to growth inhibition tests against two SRB strains, D. vulgaris and D. desulfuricans. Five fractions showed growth inhibition against both strains while seven inhibited D. desulfuricans only. The crude extracts did not show growth inhibition on both strains but were proven to be potent in preventing the formation of biofilm. Growth inhibition tests of the same set of crude extracts against Comamonas denitrificans did not show positive results. The fractions will be subjected to biofilm inhibition and dissociation assay as well. The delivery system to be evaluated first was foam. The ''foam pig'' components of surfactants and water were tested with the biocide addition. The first chemical and physical parameters to be tested were pH and surfactants. Tests using the fractionated pepper extracts are progressing rapidly. Gas chromatographic analysis on a number of fractions is underway. Involvement of other microorganisms in the tests will be extended. The foam application method has been initiated and is being developed.« less

  2. 7 CFR 58.148 - Plant records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... showing number and percent of total in each class. (2) Retests, if initial test places milk in probationary status. (3) Rejections of raw milk over No. 3 in quality. (b) Pasteurization recorder charts.... (Approved by the Office of Management and Budget under OMB control number 0583-0047) 1 1 Editorial Note: See...

  3. 49 CFR 180.217 - Requalification requirements for MEGCs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Requalification requirements for MEGCs. (a) Periodic inspections. Each MEGC must be given an initial visual...) The 5-year periodic inspection must include an external examination of the structure, the pressure... specified in Table 1 in § 180.207. (b) Exceptional inspection and test. If a MEGC shows evidence of damaged...

  4. 49 CFR 180.217 - Requalification requirements for MEGCs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Requalification requirements for MEGCs. (a) Periodic inspections. Each MEGC must be given an initial visual...) The 5-year periodic inspection must include an external examination of the structure, the pressure... specified in Table 1 in § 180.207. (b) Exceptional inspection and test. If a MEGC shows evidence of damaged...

  5. 49 CFR 180.217 - Requalification requirements for MEGCs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Requalification requirements for MEGCs. (a) Periodic inspections. Each MEGC must be given an initial visual...) The 5-year periodic inspection must include an external examination of the structure, the pressure... specified in Table 1 in § 180.207. (b) Exceptional inspection and test. If a MEGC shows evidence of damaged...

  6. 49 CFR 180.217 - Requalification requirements for MEGCs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Requalification requirements for MEGCs. (a) Periodic inspections. Each MEGC must be given an initial visual...) The 5-year periodic inspection must include an external examination of the structure, the pressure... specified in Table 1 in § 180.207. (b) Exceptional inspection and test. If a MEGC shows evidence of damaged...

  7. 49 CFR 180.217 - Requalification requirements for MEGCs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Requalification requirements for MEGCs. (a) Periodic inspections. Each MEGC must be given an initial visual...) The 5-year periodic inspection must include an external examination of the structure, the pressure... specified in Table 1 in § 180.207. (b) Exceptional inspection and test. If a MEGC shows evidence of damaged...

  8. Selecting honey bees for worker brood that reduces the reproduction of Varroa destructor

    USDA-ARS?s Scientific Manuscript database

    We investigated an effect of Apis mellifera worker brood on the reproduction of Varroa destructor as a resistance trait by conducting seven generations of bidirectional selection. Initial tests showed two-fold differences in mite fecundity (progeny per foundress mites) between colonies of different...

  9. An Evaluation of 25 Selected ToxCast Chemicals in Medium-Throughput Assays to Detect Genotoxicity

    EPA Science Inventory

    ABSTRACTToxCast is a multi-year effort to develop a cost-effective approach for the US EPA to prioritize chemicals for toxicity testing. Initial evaluation of more than 500 high-throughput (HT) microwell-based assays without metabolic activation showed that most lacked high speci...

  10. Discourse Updating after Reading a Counterfactual Event

    ERIC Educational Resources Information Center

    de Vega, Manuel; Urrutia, Mabel

    2012-01-01

    This paper explores the temporal course of discourse updating after reading counterfactual events. To test the accessibility to discourse information, readers were asked to identify probes related to initial events in the text, previous to the counterfactual, or probes related to the critical counterfactual events. Experiment 1 showed that 500 ms…

  11. 7 CFR 58.148 - Plant records.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... showing number and percent of total in each class. (2) Retests, if initial test places milk in probationary status. (3) Rejections of raw milk over No. 3 in quality. (b) Pasteurization recorder charts.... (Approved by the Office of Management and Budget under OMB control number 0583-0047) 1 1 Editorial Note: See...

  12. The volatilization of SPLAT® for use in pheromone mating disruption of cranberry pests

    USDA-ARS?s Scientific Manuscript database

    The paraffin-based pheromone carrier, SPLAT, was tested for its volatilization rate. A multi-factorial study was initiated to examine the interactive effects of point-source size, shape, and duration. The study showed that tremendous amounts of the pheromone were released early, followed by a gradua...

  13. Flight evaluation of a hydromechanical backup control for the digital electronic engine control system in an F100 engine

    NASA Technical Reports Server (NTRS)

    Walsh, K. R.; Burcham, F. W.

    1984-01-01

    The backup control (BUC) features, the operation of the BUC system, the BUC control logic, and the BUC flight test results are described. The flight test results include: (1) transfers to the BUC at military and maximum power settings; (2) a military power acceleration showing comparisons bvetween flight and simulation for BUC and primary modes; (3) steady-state idle power showing idle compressor speeds at different flight conditions; and (4) idle-to-military power BUC transients showing where cpmpressor stalls occurred for different ramp rates and idle speeds. All the BUC transfers which occur during the DEEC flight program are initiated by the pilot. Automatic transfers to the BUC do not occur.

  14. Field and laboratory comparison of the sensitivity and reliability of cocaine detection on currency using chemical sensors, humans, K-9s, and SPME/GC/MS/MS analysis

    NASA Astrophysics Data System (ADS)

    Furton, Kenneth G.; Hsu, Ya-Li; Luo, Tien-Ying; Norelus, Arnold; Rose, Stefan

    1999-02-01

    Reports that money in general circulation is contaminated with cocaine have resulted in contaminated money theories purporting that any person carrying currency could potentially initiate a drug dog alert. Field tests on dozens of different drug detector dogs with widely varying breeds, ages and training regimes show a consistent threshold level of 1 - 10 (mu) g of methyl benzoate spiked along with cocaine on U.S. currency or 0.1 - 1 ng/sec methyl benzoate diffusion required to initiate an alert. No other substance studied to data has initiated consistent responses by the drug dogs studied.

  15. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  16. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  17. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  18. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  19. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  20. 10 CFR 26.139 - Reporting initial validity and drug test results.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Reporting initial validity and drug test results. 26.139 Section 26.139 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.139 Reporting initial validity and drug test results. (a) The licensee testing facility shall...

  1. 10 CFR 26.139 - Reporting initial validity and drug test results.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Reporting initial validity and drug test results. 26.139 Section 26.139 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.139 Reporting initial validity and drug test results. (a) The licensee testing facility shall...

  2. 10 CFR 26.139 - Reporting initial validity and drug test results.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Reporting initial validity and drug test results. 26.139 Section 26.139 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.139 Reporting initial validity and drug test results. (a) The licensee testing facility shall...

  3. Verbal suppression and strategy use: a role for the right lateral prefrontal cortex?

    PubMed

    Robinson, Gail A; Cipolotti, Lisa; Walker, David G; Biggs, Vivien; Bozzali, Marco; Shallice, Tim

    2015-04-01

    Verbal initiation, suppression and strategy generation/use are cognitive processes widely held to be supported by the frontal cortex. The Hayling Test was designed to tap these cognitive processes within the same sentence completion task. There are few studies specifically investigating the neural correlates of the Hayling Test but it has been primarily used to detect frontal lobe damage. This study investigates the components of the Hayling Test in a large sample of patients with unselected focal frontal (n = 60) and posterior (n = 30) lesions. Patients and controls (n = 40) matched for education, age and sex were administered the Hayling Test as well as background cognitive tests. The standard Hayling Test clinical measures (initiation response time, suppression response time, suppression errors and overall score), composite errors scores and strategy-based responses were calculated. Lesions were analysed by classical frontal/posterior subdivisions as well as a finer-grained frontal localization method and a specific contrast method that is somewhat analogous to voxel-based lesion mapping methods. Thus, patients with right lateral, left lateral and superior medial lesions were compared to controls and patients with right lateral lesions were compared to all other patients. The results show that all four standard Hayling Test clinical measures are sensitive to frontal lobe damage although only the suppression error and overall scores were specific to the frontal region. Although all frontal patients produced blatant suppression errors, a specific right lateral frontal effect was revealed for producing errors that were subtly wrong. In addition, frontal patients overall produced fewer correct responses indicative of developing an appropriate strategy but only the right lateral group showed a significant deficit. This problem in strategy attainment and implementation could explain, at least in part, the suppression error impairment. Contrary to previous studies there was no specific frontal effect for verbal initiation. Overall, our results support a role for the right lateral frontal region in verbal suppression and, for the first time, in strategy generation/use. © The Author (2015). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Analysis and Testing of a LIDAR-Based Approach to Terrain Relative Navigation for Precise Lunar Landing

    NASA Technical Reports Server (NTRS)

    Johnson, Andrew E.; Ivanov, Tonislav I.

    2011-01-01

    To increase safety and land near pre-deployed resources, future NASA missions to the moon will require precision landing. A LIDAR-based terrain relative navigation (TRN) approach can achieve precision landing under any lighting conditions. This paper presents results from processing flash lidar and laser altimeter field test data that show LIDAR TRN can obtain position estimates less than 90m while automatically detecting and eliminating incorrect measurements using internal metrics on terrain relief and data correlation. Sensitivity studies show that the algorithm has no degradation in matching performance with initial position uncertainties up to 1.6 km

  5. Influence of Mechanical and Chemical Degradation in the Surface Roughness, Gloss, and Color of Microhybrid Composites.

    PubMed

    Lemos, Cleidiel Aa; Mauro, Silvio J; Dos Santos, Paulo H; Briso, Andre Lf; Fagundes, Ticiane C

    2017-04-01

    The aim of this study was to investigate the association of different degradations on the roughness, gloss, and color changes of microhybrid composites. Ten specimens were prepared for Charisma, Amelogen Plus, Point 4, and Opallis resins. Surfaces were polished and baseline measurements of roughness, gloss, and color were recorded. Specimens were then submitted to chemical and mechanical challenges, and the specimens were reevaluated. Roughness and gloss were analyzed by Kruskal -Wallis and Dunn's test (p < 0.05). Color change (ΔE) was analyzed by one-way analysis of variance and Tukey's tests (p < 0.05). The initial and final data were compared using the Wilcoxon test (p < 0.05). Spearman test checked the correlation between the roughness and gloss (p < 0.05). Regarding surface roughness and gloss, there was no difference between composites before challenges. However, all composites showed a significant increase of roughness after challenges, with highest values for Charisma. The gloss was influenced by challenges, evidencing the best gloss for Point 4. Charisma showed the highest value of color change. There was no correlation between surface roughness and gloss for the initial analysis, and after the challenges. Composites were influenced by association of challenges, and Charisma showed the highest changes for roughness, gloss, and color. The type of composite resin influenced the properties of materials, which are surface roughness, gloss, and color change. The dentist should be aware of the performance of different brands, to choose the correct required composite resin for each type of patient or region to be restored.

  6. Removal of cesium from simulated liquid waste with countercurrent two-stage adsorption followed by microfiltration.

    PubMed

    Han, Fei; Zhang, Guang-Hui; Gu, Ping

    2012-07-30

    Copper ferrocyanide (CuFC) was used as an adsorbent to remove cesium. Jar test results showed that the adsorption capacity of CuFC was better than that of potassium zinc hexacyanoferrate. Lab-scale tests were performed by an adsorption-microfiltration process, and the mean decontamination factor (DF) was 463 when the initial cesium concentration was 101.3μg/L, the dosage of CuFC was 40mg/L and the adsorption time was 20min. The cesium concentration in the effluent continuously decreased with the operation time, which indicated that the used adsorbent retained its adsorption capacity. To use this capacity, experiments on a countercurrent two-stage adsorption (CTA)-microfiltration (MF) process were carried out with CuFC adsorption combined with membrane separation. A calculation method for determining the cesium concentration in the effluent was given, and batch tests in a pressure cup were performed to verify the calculated method. The results showed that the experimental values fitted well with the calculated values in the CTA-MF process. The mean DF was 1123 when the dilution factor was 0.4, the initial cesium concentration was 98.75μg/L and the dosage of CuFC and adsorption time were the same as those used in the lab-scale test. The DF obtained by CTA-MF process was more than three times higher than the single-stage adsorption in the jar test. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Sibling response to initial antiepileptic medication predicts treatment success.

    PubMed

    Ueda, Keisuke; Serajee, Fatema; Rajlich, Jan; Taraman, Sharief; Steckling, Lindsey; Huq, Ahm M

    2017-10-01

    A recent study focusing on a response to antiepileptic drugs (AED) among siblings for epilepsy showed a similar response among epileptic siblings to specific AEDs or AED combinations. Currently, however, family history of treatment response to AEDs is not readily employed in deciding which initial medication to use when treating patients with epilepsy. We tested the hypothesis that sibling response to initial AED predicts treatment success. Presumed siblings were identified from a single-center database of patients diagnosed with epilepsy by matching last name, address, and name of parent(s). We identified 28 sibling pairs and two sibling trios with epilepsy. Seventeen of these sibling pairs were started on the same initial AED, with 15 sibling pairs having the same type of epilepsy. The remaining 11 pairs were started on a different initial AED, with 8 of these sibling pairs having the same type of epilepsy. Subjects with seizure freedom for a period of ≥1year were classified as a "responder". When at least one of the sibling pair responded to an initial AED, the proportion of the other siblings also responding to the initial AED was significantly higher if the siblings were treated with the same AED (8/11) compared to siblings who were treated with different AED (1/10) (Fisher's exact test, p-value=0.0075). These findings suggest that sibling response to initial AED is predictive of the success of AED therapy. This study is limited by a small cohort and retrospective design. Future, larger prospective studies are needed to reproduce and further validate these findings. Copyright © 2017. Published by Elsevier B.V.

  8. Effectiveness of physical therapy for patients with neck pain: an individualized approach using a clinical decision-making algorithm.

    PubMed

    Wang, Wendy T J; Olson, Sharon L; Campbell, Anne H; Hanten, William P; Gleeson, Peggy B

    2003-03-01

    The purpose of this study was to determine the effectiveness of an individualized physical therapy intervention in treating neck pain based on a clinical reasoning algorithm. Treatment effectiveness was examined by assessing changes in impairment, physical performance, and disability in response to intervention. One treatment group of 30 patients with neck pain completed physical therapy treatment. The control group of convenience was formed by a cohort group of 27 subjects who also had neck pain but did not receive treatment for various reasons. There were no significant differences between groups in demographic data and the initial test scores of the outcome measures. A quasi-experimental, nonequivalent, pretest-posttest control group design was used. A physical therapist rendered an eclectic intervention to the treatment group based on a clinical decision-making algorithm. Treatment outcome measures included the following five dependent variables: cervical range of motion, numeric pain rating, timed weighted overhead endurance, the supine capital flexion endurance test, and the Patient Specific Functional Scale. Both the treatment and control groups completed the initial and follow-up examinations, with an average duration of 4 wk between tests. Five mixed analyses of variance with follow-up tests showed a significant difference for all outcome measures in the treatment group compared with the control group. After an average 4 wk of physical therapy intervention, patients in the treatment group demonstrated statistically significant increases of cervical range of motion, decrease of pain, increases of physical performance measures, and decreases in the level of disability. The control group showed no differences in all five outcome variables between the initial and follow-up test scores. This study delineated algorithm-based clinical reasoning strategies for evaluating and treating patients with cervical pain. The algorithm can help clinicians classify patients with cervical pain into clinical patterns and provides pattern-specific guidelines for physical therapy interventions. An organized and specific physical therapy program was effective in improving the status of patients with neck pain.

  9. 40 CFR 63.6610 - By what date must I conduct the initial performance tests or other initial compliance...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... initial performance tests or other initial compliance demonstrations if I own or operate a stationary RICE... performance tests or other initial compliance demonstrations if I own or operate a stationary RICE with a site... stationary RICE with a site rating of more than 500 brake HP located at a major source of HAP emissions you...

  10. 40 CFR 63.6610 - By what date must I conduct the initial performance tests or other initial compliance...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... initial performance tests or other initial compliance demonstrations if I own or operate a stationary RICE... performance tests or other initial compliance demonstrations if I own or operate a stationary RICE with a site... stationary RICE with a site rating of more than 500 brake HP located at a major source of HAP emissions you...

  11. Adjustable typography: an approach to enhancing low vision text accessibility.

    PubMed

    Arditi, Aries

    2004-04-15

    Millions of people have low vision, a disability condition caused by uncorrectable or partially correctable disorders of the eye. The primary goal of low vision rehabilitation is increasing access to printed material. This paper describes how adjustable typography, a computer graphic approach to enhancing text accessibility, can play a role in this process, by allowing visually-impaired users to customize fonts to maximize legibility according to their own visual needs. Prototype software and initial testing of the concept is described. The results show that visually-impaired users tend to produce a variety of very distinct fonts, and that the adjustment process results in greatly enhanced legibility. But this initial testing has not yet demonstrated increases in legibility over and above the legibility of highly legible standard fonts such as Times New Roman.

  12. Integrated testing strategies can be optimal for chemical risk classification.

    PubMed

    Raseta, Marko; Pitchford, Jon; Cussens, James; Doe, John

    2017-08-01

    There is an urgent need to refine strategies for testing the safety of chemical compounds. This need arises both from the financial and ethical costs of animal tests, but also from the opportunities presented by new in-vitro and in-silico alternatives. Here we explore the mathematical theory underpinning the formulation of optimal testing strategies in toxicology. We show how the costs and imprecisions of the various tests, and the variability in exposures and responses of individuals, can be assembled rationally to form a Markov Decision Problem. We compute the corresponding optimal policies using well developed theory based on Dynamic Programming, thereby identifying and overcoming some methodological and logical inconsistencies which may exist in the current toxicological testing. By illustrating our methods for two simple but readily generalisable examples we show how so-called integrated testing strategies, where information of different precisions from different sources is combined and where different initial test outcomes lead to different sets of future tests, can arise naturally as optimal policies. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Evaluation of children with lymphatic malformations of the head and neck using the Cologne Disease Score.

    PubMed

    Wiegand, Susanne; Eivazi, Behfar; Zimmermann, Annette P; Sesterhenn, Andreas M; Werner, Jochen A

    2009-07-01

    To assess the disease-related impairments of children with lymphatic malformations of the head and neck and their changes after therapy using the Cologne Disease Score (CDS). 29 children with lymphatic malformations of the head and neck were evaluated regarding their symptoms before and after therapy using the CDS. The Wilcoxon test for dependent groups was used to compare the CDS at initial visit before treatment and last visit after treatment. The CDS of patients belonging to the moderate (initial CDS: more than eight points) and advanced disease group (initial CDS: five, six or seven points) significantly increased after therapy while the patients in the severe disease group (initial CDS: lower than four points) showed no significant improvement of CDS. Patients with stage IV and especially stage V lymphatic malformations according to de Serres showed considerably lower pre- and posttherapeutic CDS levels than those of stage I and II. The visual impairment is not mapped by the CDS, therefore item vision should be added to the CDS to make an evaluation of all lymphatic malformations of the head and neck possible. The present series could show that especially patients with a moderate or advanced disease according to the CDS may profit from therapeutic interventions.

  14. Hypervelocity penetration against mechanical properties of target materials

    NASA Astrophysics Data System (ADS)

    Kamarudin, Khairul Hasni; Abdullah, Mohamad Faizal; Zaidi, Ahmad Mujahid Ahmad; Nor, Norazman M.; Ismail, Ariffin; Yusof, Mohammed Alias; Hilmi, Ahmad Humaizi

    2018-02-01

    This paper study the mechanical properties behavior of metal plates against hypervelocity penetration caused by shaped charge. Five different materials were used as target specimen fabricated from welded stacks of material plates, namely Rolled Homogeneous Armor (RHA), Hardox-500, mild steel, aluminum and brass. Specimens had undergone an initial monolithic test consist of tensile tests and microstructure observations, followed by series of hydrodynamics penetration blast tests using shape charge mechanism. Results from blast test shows that the least penetrated specimen is RHA (58mm) followed by Hardox-500 (92 mm), mild steel (110 mm), Brass (155 mm) and aluminum 238 mm). Comparing these with the specimen yield strength from the tensile test results shows that Hardox-500 has higher yield strength (Sy) followed by RHA, mild steel, brass and aluminum, which are 1370 MPa, 1320 MPa, 280,221 respectively, which are not inversely proportional to the penetration. However, the ultimate tensile strength (Sut) where the RHA were the highest followed by Hardox-500, mild steel, brass and aluminum, were inversely proportional with the depth of penetration. The penetration results also show consistence relation with energy absorption.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gangopadhyay, Arup; McWatt, D. G.; Zdrodowski, R. J.

    Engine oils play a critical role in friction reduction. Improvements in engine oil technology steadily improved fuel economy as the industry moved through ILSAC GF-1 to GF-5 specifications. These improvements were influenced by changes in base oil chemistry, development of new friction modifiers and their treat levels, and the total additive package consisting of various other components. However, the improvements are incremental and further fuel consumption reduction opportunities are becoming more challenging. Polyalkylene glycol (PAG) based engine oils are being explored as a step forward for significant fuel consumption reduction. Although PAG fluids are used in many industrial applications, itsmore » application as an engine oil has been explored in a limited way. The objective of this project is to deep dive in exploring the applicability of PAG technology in engine oil, understanding the benefits, and limitations, elucidating the mechanism(s) for friction benefits, if any, and finally recommending how to address any limitations. The project was designed in four steps, starting with selection of lubricant technology, followed by friction and wear evaluations in laboratory bench tests which are relatively simple and inexpensive and also served as a screener for further evaluation. Selected formulations were chosen for more complex engine component level tests i.e., motored valvetrain friction and wear, piston ring friction using a motored single cylinder, and motored engine tests. A couple of formulations were further selected based on component level tests for engine dyno tests i.e., Sequence VID (ASTM D6709) for fuel economy, Sequence IVA (ASTM D6891) for valvetrain wear, and Sequence VG (ASTM D6593) for sludge and varnish protection. These are some of the industry standard tests required for qualifying engine oils. Out of these tests, a single PAG oil was selected for chassis roll dynamometer tests for fuel economy and emission measurements using FTP (Federal Test Procedure) metro/highway cycles. Five different PAG chemistries were selected by varying the starting alcohol, the oxide monomers (ethylene oxide, propylene oxide, or butylene oxide), capped or uncapped, homopolymer or random copolymer. All formulations contained a proprietary additive package and one which contained additional antiwear and friction modifier additives. Laboratory bench tests (Pin-on-Disk, High Frequency Reciprocating Rig (HFRR), Block-on-Ring, Mini-Traction Machine (MTM) identified formulations having friction, wear, and load carrying characteristics similar to or better than baseline GF-5 SAE 5W-20 oil. Motored valvetrain and motored piston ring friction tests showed nearly 50% friction reduction for some of the PAG formulations compared to GF-5 SAE 5W-20 oil. Motored engine tests showed up to 15% friction benefit over GF-5 SAE 5W-20 oil. It was observed that friction benefits are more related to PAG base oil chemistry than their lower viscosity compared to GF-5 SAE 5W-20 oil. Analysis of wear surfaces from laboratory bench tests and bucket tappets from motored valvetrain tests confirmed the presence of PAG molecules. The adsorption of these polar molecules is believed to be reason for friction reduction. However, the wear surfaces also had thin tribo-film derived from additive components. The tribo-film consisting of phosphates, sulfides, and molybdenum disulfide (when molybdenum additive was present) were observed for both GF-5 SAE 5W-20 and PAG fluids. However, when using PAG fluids, motored valvetrain tests showed high initial wear, which is believed to be due to delay in protective tribo-film formation. After the initial wear, the wear rate of PAG fluids was comparable to GF-5 SAE 5W-20 oil. The PAG oil containing additional antiwear and friction reducing additives showed low initial wear as expected. However, when this oil was evaluated in Sequence IVA test, it showed initially low wear comparable to GF-5 oil but wear accelerated with oil aging indicating rapid deterioration of additive components. ASTM Sequence VG test showed good sludge protection capability but failed to meet varnish rating for GF-5 requirement. Chassis roll dynamometer tests with PAG oil 15-1 showed about 1% fuel economy benefit over GF-5 SAE 5W-20 oil in EPA city cycles only and when the oil was slightly aged (500 miles). No fuel economy benefits could be observed in combined EPA metro/highway cycles. Also, no fuel economy benefit could be observed with continued (500- 10000 miles) oil aging. However, the emission level was comparable to the reference oil and was within EPA limits. Analysis of the PAG oil following tests showed low iron content although additive components were significantly degraded. The results indicate that PAG fluids have significant friction reduction potential but there are challenges with wear and varnish protection capabilities. These limitations are primarily because the selected additive components were chosen to provide a fluid with no metal content that forms little or no sulphated ash. Significant development work is needed to identify additive components compatible with PAG chemistry including their solubility in PAG oil. Miscibility of PAG fluids with mineral base oil is another challenge for oil change service. There is PAG chemistry (oil soluble PAG, OSP) which is soluble in mineral oils but the formulation explored in this investigation did not show significant friction reduction in motored engine tests. Again, highlighting the need for additive development for specific PAG chemistry. The thermal oxidation behavior of these oils has not been explored in this investigation and needs attention.« less

  16. Repeatability of a dynamic rollover test system.

    PubMed

    Seppi, Jeremy; Toczyski, Jacek; Crandall, Jeff R; Kerrigan, Jason

    2016-08-17

    The goal of this study was to characterize the rollover crash and to evaluate the repeatability of the Dynamic Rollover Test System (DRoTS) in terms of initial roof-to-ground contact conditions, vehicle kinematics, road reaction forces, and vehicle deformation. Four rollover crash tests were performed on 2 pairs of replicate vehicles (2 sedan tests and 2 compact multipurpose van [MPV] tests), instrumented with a custom inertial measurement unit to measure vehicle and global kinematics and string potentiometers to measure pillar deformation time histories. The road was instrumented with load cells to measure reaction loads and an optical encoder to measure road velocity. Laser scans of pre- and posttest vehicles were taken to provide detailed deformation maps. Initial conditions were found to be repeatable, with the largest difference seen in drop height of 20 mm; roll rate, roll angle, pitch angle, road velocity, drop velocity, mass, and moment of inertia were all 7% different or less. Vehicle kinematics (roll rate, road speed, roll and pitch angle, global Z' acceleration, and global Z' velocity) were similar throughout the impact; however, differences were seen in the sedan tests because of a vehicle fixation problem and differences were seen in the MPV tests due to an increase in reaction forces during leading side impact likely caused by disparities in roll angle (3° difference) and mass properties (2.2% in moment of inertia [MOI], 53.5 mm difference in center of gravity [CG] location). Despite those issues, kinetic and deformation measures showed a high degree of repeatability, which is necessary for assessing injury risk in rollover because roof strength positively correlates with injury risk (Brumbelow 2009). Improvements of the test equipment and matching mass properties will ensure highly repeatable initial conditions, vehicle kinematics, kinetics, and deformations.

  17. The prevalence of reversible airway obstruction in professional football players.

    PubMed

    Ross, R G

    2000-12-01

    To determine the prevalence of reversible airway obstruction in a group of professional football training camp participants. All attendees at a Canadian Football League team rookie preseason training camp were invited to participate in a protocol designed to elicit symptoms and signs of reversible airway obstruction (asthma) during the initial preparticipation examination. Those agreeing to the protocol completed a questionnaire containing standardized inquiries about a past history of asthma and the presence of symptoms. Participants then underwent spirometry testing to determine lung function before and after receiving a standardized dose of bronchodilator medication. Players showing evidence of airway obstruction during initial testing and still on the team roster underwent repeat spirometry testing and formal pulmonary function testing during the football season. The follow-up pulmonary function tests were performed to determine those that might benefit from treatment for asthma. Nineteen of 34 (56%) players agreeing to participate had significant reversible airway obstruction as defined by a 12% or greater reversibility in forced expiratory volume in one second (FEV1), peak expiratory flow rate (PEFR), and/or forced expiratory flow rate between 25 and 75% of forced vital capacity (FEF 25-75). In most participants, the diagnosis was made on the basis of spirometry alone. Of those testing positive during initial inquiry, 88% remained positive on repeat spirometry, and 73% had reversible airway obstruction during more stringently controlled hospital-based pulmonary function testing. Those players treated for previously undiagnosed asthma noted an improvement in subjective athletic performance during the football season. Based on the remarkably high prevalence of undiagnosed asthma in this group, it may prove worthwhile to test elite football players using lung function parameters.

  18. Environmental Fate and Biological Consequences of Chemicals Related to Air Force Activities

    DTIC Science & Technology

    1982-09-01

    milliliters of a 10% solution over a 78.5-square centimeter surface. Sample treated cores were tested under laboratory conditions and in field studies and using...natural weather conditions for comparative tests. No Sig- nificant differences were noted between field and laboratory conditions . Biological...JP-4- and JP-5-dosed cores initially show a stressed condition as indicated by an increased rate in CO2 produc- tion followed by a rate of CO2

  19. Development of an Acetate-Fed or Sugar-Fed Microbial Power Generator for Military Bases

    DTIC Science & Technology

    2011-01-01

    quarter. We tested graphite and stainless steel as anode materials for ARB growth, showing the greater suitability of carbon fibers as anode material...microbial electrolysis cells (MECs) with graphite rods and stainless steel meshes as anodes to select the optimum material for use in MFC modules to...be tested in the future. We selected meshes made from 316-grade stainless steel for these initial studies. We conducted several trials with the MECs

  20. Debonding in Composite Skin/Stringer Configurations Under Multi-Axial Loading

    NASA Technical Reports Server (NTRS)

    Cvitkovich, Michael K.; Krueger, Ronald; OBrien, T.; Minguet, Pierre J.

    2004-01-01

    The objective of this work was to investigate the damage mechanisms in composite bonded skin/stringer constructions under uniaxial and biaxial (in-plane/out-of-plane) loading conditions as typically experienced by aircraft crown fuselage panels. The specimens for all tests were identical and consisted of a tapered composite flange, representing a stringer or frame, bonded onto a composite skin. Tests were performed under monotonic loading conditions in tension, three-point bending, and combined tension/bending to evaluate the debonding mechanisms between the skin and the bonded stringer. For combined tension/bending testing, a unique servohydraulic load frame was used that was capable of applying both loads simultaneously. Microscopic investigations of the specimen edges were used to document the damage occurrence and to identify typical damage patterns. The observations showed that, for all three load cases, failure initiated in the flange near the flange tip causing the flange to almost fully debond from the skin. A two-dimensional plain-strain finite element model was developed to analyze the different test cases using a geometrically nonlinear solution. For all three loading conditions, principal stresses exceeded the transverse strength of the material in the flange area. Additionally, delaminations of various lengths were simulated in the locations where delaminations were experimentally observed. The analyses showed that unstable delamination propagation is likely to occur at the loads corresponding to matrix ply crack initiation for all three loadings.

  1. Inertial Gait Phase Detection for control of a drop foot stimulator Inertial sensing for gait phase detection.

    PubMed

    Kotiadis, D; Hermens, H J; Veltink, P H

    2010-05-01

    An Inertial Gait Phase Detection system was developed to replace heel switches and footswitches currently being used for the triggering of drop foot stimulators. A series of four algorithms utilising accelerometers and gyroscopes individually and in combination were tested and initial results are shown. Sensors were positioned on the outside of the upper shank. Tests were performed on data gathered from a subject, sufferer of stroke, implanted with a drop foot stimulator and triggered with the current trigger, the heel switch. Data tested includes a variety of activities representing everyday life. Flat surface walking, rough terrain and carpet walking show 100% detection and the ability of the algorithms to ignore non-gait events such as weight shifts. Timing analysis is performed against the current triggering method, the heel switch. After evaluating the heel switch timing against a reference system, namely the Vicon 370 marker and force plates system. Initial results show a close correlation between the current trigger detection and the inertial sensor based triggering algorithms. Algorithms were tested for stairs up and stairs down. Best results are observed for algorithms using gyroscope data. Algorithms were designed using threshold techniques for lowest possible computational load and with least possible sensor components to minimize power requirements and to allow for potential future implantation of sensor system.

  2. Association Between Direct-to-Consumer Advertising and Testosterone Testing and Initiation in the United States, 2009–2013

    PubMed Central

    Layton, J. Bradley; Kim, Yoonsang; Alexander, G. Caleb; Emery, Sherry L.

    2017-01-01

    IMPORTANCE Testosterone initiation increased substantially in the United States from 2000 to 2013, especially among men without clear indications. Direct-to-consumer advertising (DTCA) also increased during this time. OBJECTIVE To investigate associations between televised DTCA and testosterone testing and initiation in the United States. DESIGN, SETTING, AND POPULATION Ecologic study conducted in designated market areas (DMAs) in the United States. Monthly testosterone advertising ratings were linked to DMA-level testosterone use data from 2009–2013 derived from commercial insurance claims. Associations between DTCA and testosterone testing, initiation, and initiation without recent baseline tests were estimated using Poisson generalized estimating equations. EXPOSURES Monthly Nielsen ratings for testosterone DTCA in the 75 largest DMAs. MAIN OUTCOMES AND MEASURES (1) Rates of new serum testosterone testing; (2) rates of testosterone initiation (in-office injection, surgical implant, or pharmacy dispensing) for all testosterone products combined and for specific brands; and (3) rates of testosterone initiation without recent serum testosterone testing. RESULTS Of 17 228 599 commercially insured men in the 75 DMAs, 1 007 990 (mean age, 49.6 [SD, 11.5] years) had new serum testosterone tests and 283 317 (mean age, 51.8 [SD, 11.3] years) initiated testosterone treatment. Advertising intensity varied by geographic region and time, with the highest intensity seen in the southeastern United States and with months ranging from no ad exposures to a mean of 13.6 exposures per household. Nonbranded advertisements were common prior to 2012, with branded advertisements becoming more common during and after 2012. Each household advertisement exposure was associated with a monthly increase in rates of new testosterone testing (rate ratio [RR], 1.006; 95% CI, 1.004–1.008), initiation (RR, 1.007; 95% CI, 1.004–1.010), and initiation without a recent test (RR, 1.008; 95% CI, 1.002–1.013). Mean absolute rate increases were 0.14 tests (95% CI, 0.09–0.19), 0.05 new initiations (95% CI, 0.03–0.08), and 0.02 initiations without a recent test (95% CI, 0.01–0.03) per 10 000 men for each monthly ad exposure over the entire period. CONCLUSIONS AND RELEVANCE Among US men residing in the 75 designated market areas, regional exposure to televised direct-to-consumer advertising was associated with greater testosterone testing, new initiation, and initiation without recent testing. PMID:28324090

  3. One Step Biomass Gas Reforming-Shift Separation Membrane Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roberts, Michael J.; Souleimanova, Razima

    2012-12-28

    GTI developed a plan where efforts were concentrated in 4 major areas: membrane material development, membrane module development, membrane process development, and membrane gasifier scale-up. GTI assembled a team of researchers to work in each area. Task 1.1 Ceramic Membrane Synthesis and Testing was conducted by Arizona State University (ASU), Task 1.2 Metallic Membrane Synthesis and Testing was conducted by the U.S. National Energy Technology Laboratory (NETL), Task 1.3 was conducted by SCHOTT, and GTI was to test all membranes that showed potential. The initial focus of the project was concentrated on membrane material development. Metallic and glass-based membranes weremore » identified as hydrogen selective membranes under the conditions of the biomass gasification, temperatures above 700C and pressures up to 30 atmospheres. Membranes were synthesized by arc-rolling for metallic type membranes and incorporating Pd into a glass matrix for glass membranes. Testing for hydrogen permeability properties were completed and the effects of hydrogen sulfide and carbon monoxide were investigated for perspective membranes. The initial candidate membrane of Pd80Cu20 chosen in 2008 was selected for preliminary reactor design and cost estimates. Although the H2A analysis results indicated a $1.96 cost per gge H2 based on a 5A (micron) thick PdCu membrane, there was not long-term operation at the required flux to satisfy the go/no go decision. Since the future PSA case yielded a $2.00/gge H2, DOE decided that there was insufficient savings compared with the already proven PSA technology to further pursue the membrane reactor design. All ceramic membranes synthesized by ASU during the project showed low hydrogen flux as compared with metallic membranes. The best ceramic membrane showed hydrogen permeation flux of 0.03 SCFH/ft2 at the required process conditions while the metallic membrane, Pd80Cu20 showed a flux of 47.2 SCFH/ft2 (3 orders of magnitude difference). Results from NETL showed Pd80Cu20 with the highest flux, therefore it was chosen as the initial and eventually, final candidate membrane. The criteria for choice were high hydrogen flux, long-term stability, and H2S tolerance. Results from SCHOTT using glass membranes showed a maximum of 0.25 SCFH/ft2, that is an order of magnitude better than the ceramic membrane but still two orders of magnitude lower than the metallic membrane. A membrane module was designed to be tested with an actual biomass gasifier. Some parts of the module were ordered but the work was stopped when a no go decision was made by the DOE.« less

  4. Crack-tip-opening angle measurements and crack tunneling under stable tearing in thin sheet 2024-T3 aluminum alloy

    NASA Technical Reports Server (NTRS)

    Dawicke, D. S.; Sutton, M. A.

    1993-01-01

    The stable tearing behavior of thin sheets 2024-T3 aluminum alloy was studied for middle crack tension specimens having initial cracks that were: flat cracks (low fatigue stress) and 45 degrees through-thickness slant cracks (high fatigue stress). The critical crack-tip-opening angle (CTOA) values during stable tearing were measured by two independent methods, optical microscopy and digital image correlation. Results from the two methods agreed well. The CTOA measurements and observations of the fracture surfaces showed that the initial stable tearing behavior of low and high fatigue stress tests is significantly different. The cracks in the low fatigue stress tests underwent a transition from flat-to-slant crack growth, during which the CTOA values were high and significant crack tunneling occurred. After crack growth equal to about the thickness, CTOA reached a constant value of 6 deg and after crack growth equal to about twice the thickness, crack tunneling stabilized. The initial high CTOA values, in the low fatigue crack tests, coincided with large three-dimensional crack front shape changes due to a variation in the through-thickness crack tip constraint. The cracks in the high fatigue stress tests reach the same constant CTOA value after crack growth equal to about the thickness, but produced only a slightly higher CTOA value during initial crack growth. For crack growth on the 45 degree slant, the crack front and local field variables are still highly three-dimensional. However, the constant CTOA values and stable crack front shape may allow the process to be approximated with two-dimensional models.

  5. A New Strategy to Enhance Cavitational Tissue Erosion Using a High-Intensity, Initiating Sequence

    PubMed Central

    Xu, Zhen; Fowlkes, J. Brian; Cain, Charles A.

    2009-01-01

    Our previous studies have shown that pulsed ultrasound can physically remove soft tissue through cavitation. A new strategy to enhance the cavitation-induced erosion is proposed wherein tissue erosion is initiated by a short, high-intensity sequence of pulses and sustained by lower intensity pulses. We investigated effects of the initiating sequence on erosion and cavitation sustained by lower intensity pulses. Multiple three-cycle pulses at a pulse repetition frequency of 20 kHz delivered by a 788-kHz focused transducer were used for tissue erosion. Fixing the initiating sequence at ISPPA of 9000 W/cm2, 16 combinations of different numbers of pulses within the initiating sequence and different sustaining pulse intensities were tested. Results showed: the initiating sequence increases the probability of erosion occurrence and the erosion rate with only slight overall increases in propagated energy; the initiating sequence containing more pulses does not increase the sustained cavitation period; and if extinguished and reinitiated, the sustained cavitation period becomes shorter after each initiation, although the waiting time between adjacent cavitation periods is random. The high-intensity, initiating sequence enhances cavitational tissue erosion and enables erosion at intensities significantly lower than what is required to initiate erosion. PMID:16921893

  6. Qualification of CASMO5 / SIMULATE-3K against the SPERT-III E-core cold start-up experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grandi, G.; Moberg, L.

    SIMULATE-3K is a three-dimensional kinetic code applicable to LWR Reactivity Initiated Accidents. S3K has been used to calculate several international recognized benchmarks. However, the feedback models in the benchmark exercises are different from the feedback models that SIMULATE-3K uses for LWR reactors. For this reason, it is worth comparing the SIMULATE-3K capabilities for Reactivity Initiated Accidents against kinetic experiments. The Special Power Excursion Reactor Test III was a pressurized-water, nuclear-research facility constructed to analyze the reactor kinetic behavior under initial conditions similar to those of commercial LWRs. The SPERT III E-core resembles a PWR in terms of fuel type, moderator,more » coolant flow rate, and system pressure. The initial test conditions (power, core flow, system pressure, core inlet temperature) are representative of cold start-up, hot start-up, hot standby, and hot full power. The qualification of S3K against the SPERT III E-core measurements is an ongoing work at Studsvik. In this paper, the results for the 30 cold start-up tests are presented. The results show good agreement with the experiments for the reactivity initiated accident main parameters: peak power, energy release and compensated reactivity. Predicted and measured peak powers differ at most by 13%. Measured and predicted reactivity compensations at the time of the peak power differ less than 0.01 $. Predicted and measured energy release differ at most by 13%. All differences are within the experimental uncertainty. (authors)« less

  7. A multi-directional tracer test in the fractured Chalk aquifer of E. Yorkshire, UK.

    PubMed

    Hartmann, S; Odling, N E; West, L J

    2007-12-07

    A multi-borehole radial tracer test has been conducted in the confined Chalk aquifer of E. Yorkshire, UK. Three different tracer dyes were injected into three injection boreholes and a central borehole, 25 m from the injection boreholes, was pumped at 330 m(3)/d for 8 days. The breakthrough curves show that initial breakthrough and peak times were fairly similar for all dyes but that recoveries varied markedly from 9 to 57%. The breakthrough curves show a steep rise to a peak and long tail, typical of dual porosity aquifers. The breakthrough curves were simulated using a 1D dual porosity model. Model input parameters were constrained to acceptable ranges determined from estimations of matrix porosity and diffusion coefficient, fracture spacing, initial breakthrough times and bulk transmissivity of the aquifer. The model gave equivalent hydraulic apertures for fractures in the range 363-384 microm, dispersivities of 1 to 5 m and matrix block sizes of 6 to 9 cm. Modelling suggests that matrix block size is the primary controlling parameter for solute transport in the aquifer, particularly for recovery. The observed breakthrough curves suggest results from single injection-borehole tracer tests in the Chalk may give initial breakthrough and peak times reasonably representative of the aquifer but that recovery is highly variable and sensitive to injection and abstraction borehole location. Consideration of aquifer heterogeneity suggests that high recoveries may be indicative of a high flow pathway adjacent, but not necessarily connected, to the injection and abstraction boreholes whereas low recoveries may indicate more distributed flow through many fractures of similar aperture.

  8. Cardiac biplane strain imaging: initial in vivo experience

    NASA Astrophysics Data System (ADS)

    Lopata, R. G. P.; Nillesen, M. M.; Verrijp, C. N.; Singh, S. K.; Lammens, M. M. Y.; van der Laak, J. A. W. M.; van Wetten, H. B.; Thijssen, J. M.; Kapusta, L.; de Korte, C. L.

    2010-02-01

    In this study, first we propose a biplane strain imaging method using a commercial ultrasound system, yielding estimation of the strain in three orthogonal directions. Secondly, an animal model of a child's heart was introduced that is suitable to simulate congenital heart disease and was used to test the method in vivo. The proposed approach can serve as a framework to monitor the development of cardiac hypertrophy and fibrosis. A 2D strain estimation technique using radio frequency (RF) ultrasound data was applied. Biplane image acquisition was performed at a relatively low frame rate (<100 Hz) using a commercial platform with an RF interface. For testing the method in vivo, biplane image sequences of the heart were recorded during the cardiac cycle in four dogs with an aortic stenosis. Initial results reveal the feasibility of measuring large radial, circumferential and longitudinal cumulative strain (up to 70%) at a frame rate of 100 Hz. Mean radial strain curves of a manually segmented region-of-interest in the infero-lateral wall show excellent correlation between the measured strain curves acquired in two perpendicular planes. Furthermore, the results show the feasibility and reproducibility of assessing radial, circumferential and longitudinal strains simultaneously. In this preliminary study, three beagles developed an elevated pressure gradient over the aortic valve (Δp: 100-200 mmHg) and myocardial hypertrophy. One dog did not develop any sign of hypertrophy (Δp = 20 mmHg). Initial strain (rate) results showed that the maximum strain (rate) decreased with increasing valvular stenosis (-50%), which is in accordance with previous studies. Histological findings corroborated these results and showed an increase in fibrotic tissue for the hearts with larger pressure gradients (100, 200 mmHg), as well as lower strain and strain rate values.

  9. Anatomical versus non-anatomical single bundle anterior cruciate ligament reconstruction: a cadaveric study of comparison of knee stability.

    PubMed

    Lim, Hong-Chul; Yoon, Yong-Cheol; Wang, Joon-Ho; Bae, Ji-Hoon

    2012-12-01

    The purpose of this study was to compare the initial stability of anatomical and non-anatomical single bundle anterior cruciate ligament (ACL) reconstruction and to determine which would better restore intact knee kinematics. Our hypothesis was that the initial stability of anatomical single bundle ACL reconstruction would be superior to that of non-anatomical single bundle ACL reconstruction. Anterior tibial translation (ATT) and internal rotation of the tibia were measured with a computer navigation system in seven pairs of fresh-frozen cadaveric knees under two testing conditions (manual maximum anterior force, and a manual maximum anterior force combined with an internal rotational force). Tests were performed at 0, 30, 60, and 90 degrees of flexion with the ACL intact, the ACL transected, and after reconstruction of one side of a pair with either anatomical or non-anatomical single bundle ACL reconstruction. Under manual maximal anterior force, both reconstruction techniques showed no significant difference of ATT when compared to ACL intact knee state at 30° of knee flexion (p > 0.05). Under the combined anterior and internal rotatory force, non-anatomical single-bundle ACL reconstruction showed significant difference of ATT compared to those in ACL intact group (p < 0.05). In contrast, central anatomical single bundle ACL reconstruction showed no significant difference of ATT compared to those in ACL intact group (p > 0.05). Internal rotation of the tibia showed no significant difference in the ACL intact, the ACL transected, non-anatomical reconstructed and anatomical reconstructed knees. Anatomical single bundle ACL reconstruction restored the initial stability closer to the native ACL under combined anterior and internal rotational forces when compared to non-anatomical ACL single bundle reconstruction.

  10. Collection and analysis of wind data for the evaluation of Wildland-Urban Interface Fire Dynamics Simulator

    NASA Astrophysics Data System (ADS)

    Espina, Chad Edward Obedoza

    The Wildland Urban-Interface Fire Dynamics Simulator (WFDS) is a computer code that is currently being developed by the National Institute of Standards and Technology (NIST). WFDS has the capability of simulating wildland fire behavior with prescribed elements such vegetative and structural fuel, topography, and weather conditions. In this initial stage of the research, support for the development of WFDS focuses on the evaluation of a wind flow simulation on a very complex, outdoor terrain. This effort is preceded by the fabrication, installation and testing of wind-sensing equipment. Foremost, wind data gathered from different sites using various instruments are compared and evaluated. The data gathered in the Trails community of Rancho Bernardo is then presented and compared to select WFDS simulations. Systems consisting of a wind vane and anemometer are currently installed in the Trails community of Rancho Bernardo. They were installed by Professor Fletcher J. Miller and me using a lift that is attached to a telescoping crane. These instruments will gather the wind data needed to show the behavioral patterns of winds influenced by the topography and obstructions such as trees and houses. They are currently installed on top of light posts. These light posts were picked based on the path of the fire influenced by the Santa Ana winds that ravaged the community in 2007. The data from these instruments were graphically represented using a Matlab code that was developed specifically for the data sets. The Matlab graphing utility plots wind speed and wind direction along with matching polar plots. Other main features also include the ability to set a time range and compare two sites in one plot. There are other wind instruments currently being tested and being analyzed to ensure correct data is being recorded. These instruments will also expand to a wider range the wind data-gathering capabilities vertically. A Sound Detecting and Ranging (SoDAR) unit gathers wind speed and direction from the sound waves, initially emitted by the SoDAR to the atmosphere, that are reflected by the air flow above the unit. Wind data has been compared to the SoDAR unit with data from instruments installed on a meteorological tower operated by the National Oceanic and Atmospheric Administration (NOAA) located in northern California. Two more SoDARs are currently in Texas where initially they were deployed 400 meters apart of each other at an airfield. Also in the same airfield, the wind instrument of an Unmanned Aerial Vehicle (UAV) SuperBat was tested and compared to the SoDARs. Lastly, a self-contained wind instrument (Wind Dart) on a UAV that was developed by the University of Colorado was tested. The instrument was used while attached to the UAV Spectra. A static test was also done in San Diego State University's low speed wind tunnel. The wind data comparison from the SoDAR and meteorological tower in Lodi, California showed close tracking to each other both in wind speed and direction. The comparison of the wind data gathered by the two SoDARs in Texas also showed close tracking to each other. As for the Wind Dart, the data gathered from the instrument and UAV Spectra are not conclusive enough to validate the abilities of the Wind Dart. The experimental procedure in testing the Wind Dart on a moving platform must be further developed. Before the aerial test of the Wind Dart, it was first tested at San Diego State University's low speed tunnel. The detected wind speed by the Wind Dart closely matches the prescribed wind speed of the wind tunnel. The data between the UAV SuperBat and SoDARs showed close tracking. Data collected by the Rancho Bernardo wind instruments shows cyclical wind patterns in the neighborhood. Initial evaluation of select WFDS simulations show data that mimics data gathered from the field.

  11. Coherent to incoherent transition of precipitates during rupture test in TP347H austenitic stainless steels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, Chang-Whan; Heo, Yoon-Uk, E-mail: yunuk01@postech.ac.kr; Heo, Nam-Hoe

    2016-05-15

    Precipitation of various particles and their growth during rupture test have been investigated in TP347H austenitic stainless steels using a transmission electron microscopy. Various precipitates of MnS, Nb-rich MC, and MnS + MC and MnS + M{sub 2}P complexes are observed in the γ matrix after rupture test at 750 °C. The MnS particles formed independently in the γ matrix show a coherency or semi-coherency with the γ matrix. The Nb-rich MC carbides show also a coherency with the γ matrix. The Nb-rich MC carbides showing a semi-coherency with the MnS also form on the surface of the coherent ormore » semi-coherent MnS particles, and they show a cube-cube orientation relationship with the MnS particles. The MnS + MC complex loses the initial coherency with the γ matrix, as the MC in the complex grows. The Nb-rich M{sub 2}P precipitates formed on the surface of the MnS particles do not show an orientation relationship with the MnS particles or the γ matrix. The MnS particles in the MnS + M{sub 2}P complex hold the initial coherency with the γ matrix. Effects of MnS precipitation followed by the formation of the complexes on rupture life of the TP347H austenitic stainless steels are discussed from the viewpoint of MnS precipitates acting as sinks of free sulfur segregating to the grain boundaries. - Highlights: • Coherent to incoherent transition of precipitates during rupture test in TP347H steels is clarified. • MnS precipitation actively retards the time to intergranular fracture. • Effect of the coherency of secondary precipitates on the coherency loss of the complex particle is compared.« less

  12. MEASURING SPORT-SPECIFIC PHYSICAL ABILITIES IN MALE GYMNASTS: THE MEN'S GYMNASTICS FUNCTIONAL MEASUREMENT TOOL.

    PubMed

    Sleeper, Mark D; Kenyon, Lisa K; Elliott, James M; Cheng, M Samuel

    2016-12-01

    Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts' USA-Gymnastics competitive level to calculate the coefficient of determination (r 2 ). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. The relationship between total MGFMT scores and subjects' current USA-Gymnastics competitive level was found to be good (r 2  = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level 3.

  13. Counselling in STD/HIV/AIDS in the context of rapid test: Perception of users and health professionals at a counselling and testing centre in Porto Alegre.

    PubMed

    Carvalho, Fernanda T; Both, Nalu S; Alnoch, Edi M; Conz, Jaqueline; Rocha, Katia B

    2016-03-01

    This article discusses the perceptions of professionals and users about counselling practices at a counselling and testing centre in Porto Alegre/RS based on interviews with 27 service users and 14 members of the staff. The following categories emerged from thematic analysis: professionals' perceptions on counselling, users' perceptions on counselling and changes in counselling due to the introduction of rapid test procedures. The results show that, although initially there were some imprecision and apparent contradictions in its use, rapid testing was considered an invitation to rethink practices, bringing service closer to users' needs. © The Author(s) 2016.

  14. Effect of initial delamination on Mode 1 and Mode 2 interlaminar fracture toughness and fatigue fracture threshold

    NASA Technical Reports Server (NTRS)

    Murri, Gretchen Bostaph; Martin, Roderick H.

    1991-01-01

    Static and fatigue double-cantilever beam (DCB) and end-notch flexure (ENF) tests were conducted to determine the effect of the simulated initial delamination in interlaminar fracture toughness, G(sub c), and fatigue fracture threshold, G(sub th). Unidirectional, 24-ply specimens of S2/SP250 glass/epoxy were tested using Kapton inserts of four different thickness - 13, 25, 75, and 130 microns, at the midplane at one end, or with tension or shear precracks, to simulate an initial delamination. To determine G(sub c), the fatigue fracture threshold below which no delamination growth would occur in less than 1 x 10(exp 6) cycles, fatigue tests were conducted by cyclically loading specimens until delamination growth was detected. Consistent values of model 1 fracture toughness, G(sub Ic), were measured from DCB specimens with inserts of thickness 75 microns or thinner, or with shear precracks. The fatigue DCB tests gave similar values of G(sub Ith) for the 13, 25, and 75 microns specimens. Results for the shear precracked specimens were significantly lower that for specimens without precracks. Results for both the static and fatigue ENF tests showed that measured G(IIc) and G(IIth) values decreased with decreasing insert thickness, so that no limiting thickness could be determined. Results for specimens with inserts of 75 microns or thicker were significantly higher than the results for precracked specimens or specimens with 13 or 25 microns inserts.

  15. Utilisation of cancer screening services by disabled women in Chile

    PubMed Central

    Rotarou, Elena S.

    2017-01-01

    Background Research has shown that women with disabilities face additional challenges in accessing and using healthcare services compared to non-disabled women. However, relatively little is known about the utilisation of cancer screening services for women with disabilities. This study addresses this gap by examining the utilisation of the Papanicolaou test and mammography for disabled women in Chile. Methods We used cross-sectional data, taken from a 2015 nationally-representative survey. Initially, we employed logistic regressions to test for differences in utilisation rates for the Papanicolaou test (66,281 observations) and the mammogram (35,294 observations) between disabled and non-disabled women. Next, logistic regressions were used to investigate the demographic, socioeconomic, and health-related factors affecting utilisation rates for cancer screening services for disabled women (sample sizes: 5,823 observations for the Papanicolaou test and 5,731 observations for the mammogram). Results Disabled women were less likely to undergo screening tests than non-disabled women. For the Papanicolaou test and mammography, the multivariable regression models showed that living in rural areas, having higher education, being affiliated with a private health insurance company, giving a good health self-assessment score, and being under medical treatment for other illnesses were associated with higher utilisation rates. On the other hand, being single, inactive with regard to employment, and having a better income were linked with lower utilisation. While utilisation rates for both disabled and non-disabled women have increased since 2006, the utilisation disparity has slightly increased. Conclusions This study shows the influence of various factors in the utilisation rates of preventive cancer screening services for disabled women. To develop effective initiatives targeting inequalities in the utilisation of cancer screening tests, it is important to move beyond an exclusively single-disease approach and acknowledge the complexity of the patient population. PMID:28459874

  16. Utilisation of cancer screening services by disabled women in Chile.

    PubMed

    Sakellariou, Dikaios; Rotarou, Elena S

    2017-01-01

    Research has shown that women with disabilities face additional challenges in accessing and using healthcare services compared to non-disabled women. However, relatively little is known about the utilisation of cancer screening services for women with disabilities. This study addresses this gap by examining the utilisation of the Papanicolaou test and mammography for disabled women in Chile. We used cross-sectional data, taken from a 2015 nationally-representative survey. Initially, we employed logistic regressions to test for differences in utilisation rates for the Papanicolaou test (66,281 observations) and the mammogram (35,294 observations) between disabled and non-disabled women. Next, logistic regressions were used to investigate the demographic, socioeconomic, and health-related factors affecting utilisation rates for cancer screening services for disabled women (sample sizes: 5,823 observations for the Papanicolaou test and 5,731 observations for the mammogram). Disabled women were less likely to undergo screening tests than non-disabled women. For the Papanicolaou test and mammography, the multivariable regression models showed that living in rural areas, having higher education, being affiliated with a private health insurance company, giving a good health self-assessment score, and being under medical treatment for other illnesses were associated with higher utilisation rates. On the other hand, being single, inactive with regard to employment, and having a better income were linked with lower utilisation. While utilisation rates for both disabled and non-disabled women have increased since 2006, the utilisation disparity has slightly increased. This study shows the influence of various factors in the utilisation rates of preventive cancer screening services for disabled women. To develop effective initiatives targeting inequalities in the utilisation of cancer screening tests, it is important to move beyond an exclusively single-disease approach and acknowledge the complexity of the patient population.

  17. Prognostic Significance of Circulating Immune Complexes in Cancer Patients

    PubMed Central

    Dass, Tushar Kanti; Ashok, Ashok

    1991-01-01

    Circulating immune complexes (CIC) were estimated in 100 cancer patients and 25 healthy control volunteers by means of the polyethylene glycol (PEG) precipitation test and latex agglutination inhibition (LAI) test. Pathological levels of CIC were found in 47% of the patients by PEG precipitation test and in 59% of the patients by LAI test; both tests were positive in 33% of the patients. Consequently, the use of the two assays resulted in 73% seropositivity for CIC. The PEG precipitation test detects antigen‐antibody complexes formed in the ratio of 2:1 (Ag2Ab), while the LAI test could detect immune complexes formed over an extended range of antigen‐antibody ratio including complexes as small as SS. CIC values were significantly higher by combined assays (P < 0.001) as compared to individual assays (P < 0.01) when compared with the control group. It was found that 75% of post‐operative follow‐up patients became seronegative for CIC in the combined assays, whereas the 25% of post‐operative patients who remained seropositive for CIC showed recurrence within three months after surgery. Immune‐complex deposition was demonstrated on malignant cells in vitro by direct immunofluorescence studies in 73.3% of patients, while 60% of patients revealed complement‐fixing antigen‐antibody complexes. It was found that 20% of patients showing positive immunofluorescence with anti‐C3‐antisera had decreased levels of CIC. Complement‐mediated cytotoxic injury results in reduction of tumor cell mass and subsequent decrease in CIC. Necrotizing and leucocytoclastic vasculitis in the tumor mass was initiated by raised CIC levels in vivo in 71% of patients. Necrosis of malignant tumors was seen in 58% of patients, and hemorrhage in 36% of patients. These changes were considered to be an aftermath of immuno‐complex vasculitis initiated by CIC. PMID:1752784

  18. Fatigue delamination onset prediction in tapered composite laminates

    NASA Technical Reports Server (NTRS)

    Murri, Gretchen Bostaph; Salpekar, Satish A.; Obrien, T. Kevin

    1989-01-01

    Tapered (0 deg) laminates of S2/CE9000 and S2/SP250 glass/epoxies, and IM6/1827I graphite/epoxy were tested in cyclic tension. The specimens usually showed some initial stable delaminations in the tapered region, but these did not affect the stiffness of the specimens, and loading was continued until the specimens either delaminated unstably, or reached 10(exp 6) to 2 x 10(exp 7) million cycles with no unstable delamination. The final unstable delamination originated at the junction of the thin and tapered regions. A finite-element model was developed for the tapered laminate with and without the initial stable delaminations observed in the tests. The analysis showed that for both cases the most likely place for an opening (Mode 1) delamination to originate is at the junction of the taper and thin regions. For each material type, the models were used to calculate the strain energy release rate, G, associated with delaminations originating at that junction and growing either into the thin region or tapered region. For the materials tested, cyclic G(sub Imax) values from DCB tests were used with the maximum strain energy release rates calculated from the finite-element analysis to predict the onset of unstable delamination at the junction as a function of fatigue cycles. The predictions were compared to experimental values of maximum cyclic load as a function of cycles to unstable delamination from fatigue tests in tapered laminates. For the IM6/1827I and S2/SP250 laminates, the predictions agreed very well with the test data. Predicted values for the S2/CE9000 were conservative compared to the test data.

  19. Results of an On-Going Long Duration Ground Test of the DS1 Flight Spare Engine

    NASA Technical Reports Server (NTRS)

    Anderson, John R.; Goodfellow, Keith D.; Polk, James E.; Shotwell, Robert F.; Rawlin, Vincent K.; Sovey, James S.; Patterson, Michael J.

    2000-01-01

    Ground testing of the DS1 night spare thruster (FT2) is presently being conducted. To date, the thruster has accumulated over 4500 hours of operation. Comparison of FT2 with the performance of the engineering model thruster 2 (EMT2) during the 8.2 khr test shows a transient, lasting for about 3000 hours, during which the discharge chamber efficiency decreases for both thrusters. The flow rates are 2% lower for FT2 than for EMT2 and the discharge chamber performance is 4.5% lower for FT2 during the transient. Sensitivity data obtained during the test show that the lower flow rate accounts for about half of the observed difference. After the initial transients decay, the performance of both thrusters is comparable with the exception of the electron backstreaming margin--which is 6 V lower for FT2.

  20. Research on Improving Low Rank Coal Caking Ability by Moderate Hydrogenation

    NASA Astrophysics Data System (ADS)

    Huang, Peng

    2017-12-01

    The hydrogenation test of low metamorphic coal was carried out by using a continuous hydrogen reactor at the temperature of (350-400)°C and the initial hydrogen pressure of 3 ~ 6Mpa. The purpose of the experiment was to increase the caking property, and the heating time was controlled from 30 to 50min. The test results show that the mild hydrogenation test, no adhesion of low metamorphic coal can be transformed into a product having adhesion, oxygen elements in coal have good removal, the calorific value of the product has been improved significantly and coal particles during pyrolysis, swelling, catalyst, hydrogenation, structural changes and the combined effects of particles a new component formed between financial and is a major cause of coal caking enhancement and lithofacies change, coal blending test showed that the product can be used effectively in the coking industry.

  1. Reliability Testing of NASA Piezocomposite Actuators

    NASA Technical Reports Server (NTRS)

    Wilkie, W.; High, J.; Bockman, J.

    2002-01-01

    NASA Langley Research Center has developed a low-cost piezocomposite actuator which has application for controlling vibrations in large inflatable smart space structures, space telescopes, and high performance aircraft. Tests show the NASA piezocomposite device is capable of producing large, directional, in-plane strains on the order of 2000 parts-per-million peak-to-peak, with no reduction in free-strain performance to 100 million electrical cycles. This paper describes methods, measurements, and preliminary results from our reliability evaluation of the device under externally applied mechanical loads and at various operational temperatures. Tests performed to date show no net reductions in actuation amplitude while the device was moderately loaded through 10 million electrical cycles. Tests were performed at both room temperature and at the maximum operational temperature of the epoxy resin system used in manufacture of the device. Initial indications are that actuator reliability is excellent, with no actuator failures or large net reduction in actuator performance.

  2. 29 CFR 1919.14 - Initial tests of cargo gear and tests after alterations, renewals or repairs.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Initial tests of cargo gear and tests after alterations, renewals or repairs. 1919.14 Section 1919.14 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) GEAR CERTIFICATION Certification of Vessels' Cargo Gear § 1919.14 Initial tests...

  3. 29 CFR 1919.14 - Initial tests of cargo gear and tests after alterations, renewals or repairs.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Initial tests of cargo gear and tests after alterations, renewals or repairs. 1919.14 Section 1919.14 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) GEAR CERTIFICATION Certification of Vessels' Cargo Gear § 1919.14 Initial tests...

  4. 29 CFR 1919.14 - Initial tests of cargo gear and tests after alterations, renewals or repairs.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Initial tests of cargo gear and tests after alterations, renewals or repairs. 1919.14 Section 1919.14 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) GEAR CERTIFICATION Certification of Vessels' Cargo Gear § 1919.14 Initial tests...

  5. 29 CFR 1919.14 - Initial tests of cargo gear and tests after alterations, renewals or repairs.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Initial tests of cargo gear and tests after alterations, renewals or repairs. 1919.14 Section 1919.14 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) GEAR CERTIFICATION Certification of Vessels' Cargo Gear § 1919.14 Initial tests...

  6. Onsite 40-kilowatt fuel cell power plant manufacturing and field test program

    NASA Technical Reports Server (NTRS)

    1985-01-01

    A joint Gas Research Institute and U.S. Department of Energy Program was initiated in 1982 to evaluate the use of fuel cell power systems for on-site energy service. Forty-six 40 kW fuel cell power plants were manufactured at the United Technologies Corporation facility in South Windsor, Connecticut, and are being delivered to host utilities and other program participants in the United States and Japan for field testing. The construction of the 46 fully-integrated power plants was completed in January 1985 within the constraints of the contract plan. The program has provided significant experience in the manufacture, acceptance testing, deployment, and support of on-site fuel cell systems. Initial field test results also show that these experimental power plants meet the performance and environmental requirements of a commercial specification. This Interim Report encompasses the design and manufacturing phases of the 40 kW Power Plant Manufacturing and Field Test program. The contract between UTC and NASA also provides UTC field engineering support to the host utilities, training programs and associated manuals for utility operating and maintenance personnel, spare parts support for a defined test period, and testing at UTC of a power plant made available from a preceding program phase. These activities are ongoing and will be reported subsequently.

  7. Gross and fine motor function in fibromyalgia and chronic fatigue syndrome.

    PubMed

    Rasouli, Omid; Fors, Egil A; Borchgrevink, Petter Chr; Öhberg, Fredrik; Stensdotter, Ann-Katrin

    2017-01-01

    This paper aimed to investigate motor proficiency in fine and gross motor function, with a focus on reaction time (RT) and movement skill, in patients with fibromyalgia (FM) and chronic fatigue syndrome (CFS) compared to healthy controls (HC). A total of 60 individuals (20 CFS, 20 FM, and 20 HC), age 19-49 years, participated in this study. Gross motor function in the lower extremity was assessed using a RT task during gait initiation in response to an auditory trigger. Fine motor function in the upper extremity was measured during a precision task (the Purdue Pegboard test) where the number of pins inserted within 30 s was counted. No significant differences were found between FM and CFS in any parameters. FM and CFS groups had significantly longer RT than HC in the gait initiation ( p =0.001, and p =0.004 respectively). In the Purdue Pegboard test, 20% in the FM group, 15% in the CFS groups, and 0% of HC group, scored below the threshold of the accepted performance. However, there were no significant differences between FM, CFS, and HC in this task ( p =0.12). Compared to controls, both CFS and FM groups displayed significantly longer RT in the gait initiation task. Generally, FM patients showed the worst results in both tests, although no group differences were found in fine motor control, according to the Purdue Pegboard test.

  8. [Trajectories of aging in a sample of elderly people: a longitudinal study].

    PubMed

    Navarro-González, Elena; Calero, María Dolores; Becerra-Reina, Dolores

    2015-01-01

    The present study analyzes variables associated with different trajectories of aging, and the level of cognitive functioning in a sample of older adults. Although this work is part of a broader investigation where initially 141 people were assessed, this paper only discusses the cognitive functioning and cognitive development of 64 older people who have been followed up four years after the initial assessment, with a mean age of 83.84 years (age range 65 to 99 years). In the initial assessment all the participants were assessed with a psychological battery that included the MEC, the verbal fluency task FVS, a sustained attention task, a working memory test, a Quality of Life Questionnaire, a scale of dependency, and the AVLT-Learning Potential test. In the follow up assessment, participants have been assessed with the MEC, the verbal fluency task FVS, and the verbal memory test AVLT-PA. the results show relatively stable trajectories of aging and that the variables that better predict cognitive evolution of the elderly are working memory and post-test score in the AVLT-LP. Despite the time lapse between the two assessments and the age of the participants, older adults have remained relatively stable in their cognitive functioning, which in part contradicts the idea that--especially after 80 years--a general decline of cognitive functioning occurs in old age. Copyright © 2014 SEGG. Published by Elsevier Espana. All rights reserved.

  9. Spatial disorientation in right-hemisphere infarction: a study of the speed of recovery.

    PubMed Central

    Meerwaldt, J D

    1983-01-01

    Sixteen patients with an infarct in the posterior region of the right hemisphere were tested at fixed intervals after a stroke (2 weeks, 6 weeks, 3 months, 6 months, 1 year) with the rod orientation test and the line orientation test. All patients initially showed spatial disorientation on the rod orientation test, while only three had a defective performance on the line orientation test. The recovery on the rod orientation test was parallel with the neurological improvement. Recovery mainly took place in the first six months after the stroke. Most patients then performed at a normal level. A relation between the size of the lesion (assessed from CT scans) and the speed of recovery was found. PMID:6101178

  10. [Short-term screening of anticarcinogenic ingredients of tea by cell biology assays].

    PubMed

    Liu, L; Han, C; Chen, J

    1998-01-01

    By using a panel of short term cell biology assays, several ingredients of tea (tea pigments, caffeine, tea polysaccharide, tea polyphenols tablet and mixed tea) were screened in order to investigate their anticarcinogenic effects. The cytokinesis block micronuclei test in V79 cells induced by mitomycin, the test of metabolic cooperation between V79 and M cells and the test of growth ability of Hela cells in soft agar were used in the screening. The results showed that the six kinds of tea ingredients tested were effective in the test involved in different stages of carcinogenesis, i.e. initiation, promotion and progression. The effects of mixed tea and tea pigments were the strongest among the ingredients tested.

  11. Sensitivity and Validity of Psychometric Tests for Assessing Driving Impairment: Effects of Sleep Deprivation

    PubMed Central

    Jongen, Stefan; Perrier, Joy; Vuurman, Eric F.; Ramaekers, Johannes G.; Vermeeren, Annemiek

    2015-01-01

    Objective To assess drug induced driving impairment, initial screening is needed. However, no consensus has been reached about which initial screening tools have to be used. The present study aims to determine the ability of a battery of psychometric tests to detect performance impairing effects of clinically relevant levels of drowsiness as induced by one night of sleep deprivation. Methods Twenty four healthy volunteers participated in a 2-period crossover study in which the highway driving test was conducted twice: once after normal sleep and once after one night of sleep deprivation. The psychometric tests were conducted on 4 occasions: once after normal sleep (at 11 am) and three times during a single night of sleep deprivation (at 1 am, 5 am, and 11 am). Results On-the-road driving performance was significantly impaired after sleep deprivation, as measured by an increase in Standard Deviation of Lateral Position (SDLP) of 3.1 cm compared to performance after a normal night of sleep. At 5 am, performance in most psychometric tests showed significant impairment. As expected, largest effect sizes were found on performance in the Psychomotor Vigilance Test (PVT). Large effects sizes were also found in the Divided Attention Test (DAT), the Attention Network Test (ANT), and the test for Useful Field of View (UFOV) at 5 and 11 am during sleep deprivation. Effects of sleep deprivation on SDLP correlated significantly with performance changes in the PVT and the DAT, but not with performance changes in the UFOV. Conclusion From the psychometric tests used in this study, the PVT and DAT seem most promising for initial evaluation of drug impairment based on sensitivity and correlations with driving impairment. Further studies are needed to assess the sensitivity and validity of these psychometric tests after benchmark sedative drug use. PMID:25668292

  12. Stability of urea in solution and pharmaceutical preparations.

    PubMed

    Panyachariwat, Nattakan; Steckel, Hartwig

    2014-01-01

    The stability of urea in solution and pharmaceutical preparations was analyzed as a function of temperature (25°-60°C), pH (3.11-9.67), and initial urea concentration (2.5%-20%). This study was undertaken to (i) obtain more extensive, quantitative information relative to the degradation of urea in both aqueous and non-aqueous solutions and in pharmaceutical preparations, and (ii) test the effects of initial urea concentration, pH, buffer, and temperature values on urea degradation. The stability analysis shows that urea is more stable at the pH range of 4-8 and the stability of urea decreases by increase in temperature for all pH values. Within the experimental range of temperature and initial urea concentration values, the lowest urea degradation was found with lactate buffer pH 6.0. The urea decomposition rate in solution and pharmaceutical preparations shows the dependence of the initial urea concentrations. At higher initial urea concentrations, the rate of degradation is a decreasing function with time. This suggests that the reverse reaction is a factor in the degradation of concentrated urea solution. For non-aqueous solvents, isopropanol showed the best effort in retarding the decomposition of urea. Since the losses in urea is directly influenced by its stability at a given temperature and pH, the stability analysis of urea by the proposed model can be used to prevent the loss and optimize the operating condition for urea-containing pharmaceutical preparations.

  13. Contribution of a contralateral hearing aid to perception of consonant voicing, intonation, and emotional state in adult cochlear implantees.

    PubMed

    Most, Tova; Gaon-Sivan, Gal; Shpak, Talma; Luntz, Michal

    2012-01-01

    Binaural hearing in cochlear implant (CI) users can be achieved either by bilateral implantation or bimodally with a contralateral hearing aid (HA). Binaural-bimodal hearing has the advantage of complementing the high-frequency electric information from the CI by low-frequency acoustic information from the HA. We examined the contribution of a contralateral HA in 25 adult implantees to their perception of fundamental frequency-cued speech characteristics (initial consonant voicing, intonation, and emotions). Testing with CI alone, HA alone, and bimodal hearing showed that all three characteristics were best perceived under the bimodal condition. Significant differences were recorded between bimodal and HA conditions in the initial voicing test, between bimodal and CI conditions in the intonation test, and between both bimodal and CI conditions and between bimodal and HA conditions in the emotion-in-speech test. These findings confirmed that such binaural-bimodal hearing enhances perception of these speech characteristics and suggest that implantees with residual hearing in the contralateral ear may benefit from a HA in that ear.

  14. Advanced Weather Awareness and Reporting Enhancements

    NASA Technical Reports Server (NTRS)

    Busquets, Anthony M. (Technical Monitor); Ruokangas, Corinne Clinton; Kelly, Wallace E., III

    2005-01-01

    AWARE (Aviation Weather Awareness and Reporting Enhancements) was a NASA Cooperative Research and Development program conducted jointly by Rockwell Scientific, Rockwell Collins, and NASA. The effort culminated in an enhanced weather briefing and reporting tool prototype designed to integrate graphical and text-based aviation weather data to provide clear situational awareness in the context of a specific pilot, flight and equipment profile. The initial implementation of AWARE was as a web-based preflight planning tool, specifically for general aviation pilots, who do not have access to support such as the dispatchers available for commercial airlines. Initial usability tests showed that for VFR (Visual Flight Rules) pilots, AWARE provided faster and more effective weather evaluation. In a subsequent formal usability test for IFR (Instrument Flight Rules) pilots, all users finished the AWARE tests faster than the parallel DUAT tests, and all subjects graded AWARE higher for effectiveness, efficiency, and usability. The decision analysis basis of AWARE differentiates it from other aviation safety programs, providing analysis of context-sensitive data in a personalized graphical format to aid pilots/dispatchers in their complex flight requirements.

  15. 49 CFR 173.56 - New explosives-definition and procedures for classification and approval.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... agency the ranges of composition of ingredients and compounds, showing the intended manufacturing... was produced to an explosives testing range if— (1) It is not a primary (a 1.1A initiating) explosive...) Ammunition with inert projectile or blank ammunition; and (4) Ammunition not exceeding 50 caliber for rifle...

  16. 49 CFR 173.56 - New explosives-definition and procedures for classification and approval.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the ranges of composition of ingredients and compounds, showing the intended manufacturing tolerances... was produced to an explosives testing range if— (1) It is not a primary (a 1.1A initiating) explosive...; (3) Ammunition with inert projectile or blank ammunition; and (4) Ammunition not exceeding 50 caliber...

  17. 49 CFR 173.56 - New explosives-definition and procedures for classification and approval.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the ranges of composition of ingredients and compounds, showing the intended manufacturing tolerances... was produced to an explosives testing range if— (1) It is not a primary (a 1.1A initiating) explosive...; (3) Ammunition with inert projectile or blank ammunition; and (4) Ammunition not exceeding 50 caliber...

  18. 49 CFR 173.56 - New explosives-definition and procedures for classification and approval.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... agency the ranges of composition of ingredients and compounds, showing the intended manufacturing... was produced to an explosives testing range if— (1) It is not a primary (a 1.1A initiating) explosive...) Ammunition with inert projectile or blank ammunition; and (4) Ammunition not exceeding 50 caliber for rifle...

  19. Implementing Reform amidst Resistance: The Regulation of Teacher Education and Work in Mexico

    ERIC Educational Resources Information Center

    Tatto, Maria Teresa; Schmelkes, Sylvia; Guevara, Maria Del Refugio; Tapia, Medardo

    2006-01-01

    Influenced by worldwide globalization forces new structures of control have emerged in Mexico at the school level, and career ladders reward teachers' compliance with testing and training schemes; nevertheless the long-standing institutions of initial teacher education continue to show a strong resistance to change. Increased accountability is…

  20. Effects of Enhanced Anchored Instruction on Skills Aligned to Common Core Math Standards

    ERIC Educational Resources Information Center

    Bottge, Brian A.; Cho, Sun-Joo

    2013-01-01

    This study compared how students with learning difficulties in math (MLD) who were randomly assigned to two instructional conditions answered items on problem solving tests aligned to the Common Core State Standards Initiative for Mathematics. Posttest scores showed improvement in the math performance of students receiving Enhanced Anchored…

  1. Do Attention Deficits Influence IQ Assessment in Children and Adolescents with ADHD?

    ERIC Educational Resources Information Center

    Jepsen, Jens Richardt M.; Fagerlund, Birgitte; Mortensen, Erik Lykke

    2009-01-01

    Objective: To characterize the relationship between IQ and attention deficits in children with ADHD and to estimate the inattention-related mean influence on IQ when children are tested before stimulant drug treatment has been initiated. Method: Studies of various methodologies are reviewed. Results: Correlation studies show mostly weak…

  2. Demulsification; industrial applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lissant, K.J.

    1983-01-01

    For scientists involved in the problems of selecting or designing demulsification programs. The author shows clearly why no pat formula exists to help out but does point out initial information required to start work. Theory. Testing. Demulsification of oil-in-water emulsions. Demulsification of water-in-oil emulsions. Demulsification of petroleum emulsions. Additional methods and areas in demulsification.

  3. A CANDY-HANDY APPROACH TO FASTER LEARNING.

    ERIC Educational Resources Information Center

    COOPER, DAVID

    THE EDUCATION IMPROVEMENT PROJECT (EIP) IS A 5-YEAR EDUCATIONAL RESEARCH PROGRAM FOR ECONOMICALLY DISADVANTAGED CHILDREN RANGING IN AGE FROM INFANCY TO 14 YEARS. THE INITIAL PHASE OF EIP CONSISTS OF INFANT TESTING WHICH BEGINS AT BIRTH. DATA ON INTELLIGENCE AND DEVELOPMENT FROM THIS PHASE OF THE PROGRAM SHOW THAT AMONG THESE CHILDREN THE…

  4. Vigilance and Avoidance of Threat in the Eye Movements of Children with Separation Anxiety Disorder

    ERIC Educational Resources Information Center

    In-Albon, Tina; Kossowsky, Joe; Schneider, Silvia

    2010-01-01

    The "vigilance-avoidance" attention pattern is found in anxious adults, who initially gaze more at threatening pictures than nonanxious adults (vigilance), but subsequently gaze less at them than nonanxious adults (avoidance). The present research, using eye tracking methodology, tested whether anxious children show the same pattern. Children with…

  5. Selecting timber species to replace killed firetree in Hawaii

    Treesearch

    Gerald A. Walters

    1970-01-01

    A species with little commercial value, firetree (Myrica faya Ait.) infests several islands of Hawaii. A test of replacing herbicide-killed firetrees by underplanting selected timber species is underway. Among the seven species planted, Austrailan toon-on the basis of its initial survival and growth-shows the most promise for reforestation. Falling...

  6. Discovery of a haplotype affecting fertility in Ayrshire dairy dattle and identification of a putative causal variant

    USDA-ARS?s Scientific Manuscript database

    Initial genomic test results for US Ayrshire dairy cattle became available in January of 2013. Several haplotypes that showed a deficiency of homozygotes were investigated to determine if they had an effect on fertility. A haplotype on chromosome 17 was determined to affect fertility, indicating tha...

  7. Does Patient Partnership in Continuing Medical Education (CME) Improve the Outcome in Osteoporosis Management.

    ERIC Educational Resources Information Center

    Pazirandeh, Mahmood

    2002-01-01

    Patients (n=672) were screened and instructed about osteoporosis; 53 of their physicians attended lectures, a control group did not. A survey of 258 patients showed doctor-ordered screening tests increased regardless of lecture attendance. Increased patient-initiated discussions about osteoporosis suggest that patient education is effective.…

  8. An Investigation into the Postbuckling Response of a Single Blade-Stiffened Composite Panel

    NASA Astrophysics Data System (ADS)

    Spediacci, Alexander Daniel

    The large strength reserves of stiffened composite structures in the postbuckling range appeal to the aerospace industry because of the high strength-to weight-ratio. Design and analysis of these large-scale, complex structures is technical, and requires major computational effort. Using the building-block approach, a smaller, single-stringer panel can be a useful and efficient tool for initial design, and can reveal critical behavior of a larger, multi-stringer panel. A characterization, through finite element modeling, of buckling and postbuckling response of a single blade-stiffened composite panel is proposed. Several factors affecting buckling and postbuckling behavior are investigated, including specimen length, initial imperfections, mode switching, and skin stringer separation. Two specimens are repeatedly tested under quasi- static compression loading well into the postbuckling range, showing no sign of damage. The test data from the specimens are used to compare and validate the nonlinear finite element models, show good correlation with the models. Ultimately, this work will serve to demonstrate the safety of stiffened structures operating in the postbuckling range and allow for thinner, lighter structures, which can increase the overall efficiency of aircraft.

  9. Using a biology-based model (DEBtox) to analyze bioassays in ecotoxicology: opportunities and recommendations.

    PubMed

    Péry, Alexandre R R; Flammarion, Patrick; Vollat, Bernard; Bedaux, Jacques J M; Kooijman, Sebastiaan A L M; Garric, Jeanne

    2002-02-01

    The conventional analysis of bioassays does not account for biological significance. However, mathematical models do exist that are realistic from a biological point of view and describe toxicokinetics and effects on test organisms of chemical compounds. Here we studied a biology-based model (DEBtox) that provides an estimate of a no-effect concentration, and we demonstrated the ability of such a model to adapt to different situations. We showed that the basic model can be extended to deal with problems usually faced during bioassays like time-varying concentrations or unsuitable choices of initial concentrations. To reach this goal, we report experimental data from Daphnia magna exposed to zinc. These data also showed the potential benefit of the model in understanding the influence of food on toxicity. We finally make some recommendations about the choice of initial concentrations, and we propose a test with a depuration period to check the relevance and the predictive capacity of the DEBtox model. In our experiments, the model performed well and proved its usefulness as a tool in risk assessment.

  10. Socialisation scheme with a high staff-patient ratio.

    PubMed

    Hollander, D; Rao, V B; McManoman, E; Harrington, N; Weeks, A; Mann, A

    1981-01-01

    Six months after a comprehensive socialisation scheme began, a prospective controlled study was carried out. The patients were tested in three practical sections - Cooking; Maintenance of Home and Clothing; Other Skills (eg. form-filling); and with a Questionnaire. Forty-eight members of an experimental group received socialisation training after initial testing. They and the 20 controls who did not undergo training were re-evaluated three months later. There was no significant difference between the groups in their initial scores. On retesting, the experimental group showed a significant improvement in Cooking (p less than 0.001), Home Maintenance (p less than 0.001) and the Questionnaire (p less than 0.05). Analysis of the inter-group differences showed significant superiority of the experimental group in Cooking (p less than 0.05) and Home Maintenance (p less than 0.05). It is suggested that such a socialisation scheme be considered for inclusion alongside other rehabilitation services in psychiatric hospitals. The emphasis on a high staff-to-patient ratio and the breakdown of each task into smaller steps emerged as essential elements in the training programme.

  11. Identification of phototransformation products of the antiepileptic drug gabapentin: Biodegradability and initial assessment of toxicity.

    PubMed

    Herrmann, Manuel; Menz, Jakob; Olsson, Oliver; Kümmerer, Klaus

    2015-11-15

    The anticonvulsant drug Gabapentin (GAB) is used for the treatment of various diseases (e.g. epilepsy, bipolar disorder, neuropathic pain) and is being consumed in high amounts. As GAB is not metabolized and shows a weak elimination in sewage treatment plants (STPs), it has been detected in surface water and even in raw potable water. Moreover, the confirmed teratogenic effects of GAB indicate the need for further investigations regarding options for the elimination of GAB in the water cycle. Little is known about the behavior of GAB during treatment with UV light, which is normally used for the disinfection of potable water and discussed for advanced wastewater treatment. In this study, GAB was exposed to polychromatic UV irradiation at different initial concentrations in aqueous solution. Afterwards the structures of the resulting phototransformation products (PTPs) were identified and elucidated by means of high-resolution mass spectrometry. GAB and photolytic mixtures were submitted to the Closed Bottle Test (CBT; OECD 301 D) to assess biodegradability. Furthermore, the toxicity of GAB and its photolytic mixtures was initially addressed on screening level using a modified luminescent bacteria test (LBT) and the umu-test (ISO/FDIS 13829). Environmentally realistic concentrations of GAB were disclosed by predicting STP influent concentrations (24.3 and 23.2 μg L(-1)). GAB with initial concentration of 100 mg L(-1) was eliminated by 80% after 128 min of direct UV irradiation, but just 9% of non-purgeable organic carbon (NPOC) was removed indicating the formation of dead-end transformation products (TPs). Structures of different PTPs were elucidated and several identical PTPs could also be identified at lower initial treatment concentrations (20 mg L(-1), 5 mg L(-1), 1 mg L(-1) and 0.1 mg L(-1)). GAB was classified as not readily biodegradable. Moreover, photo treatment did not result in better biodegradable PTPs. With increasing UV treatment duration, photolytic mixtures of GAB showed an increased inhibition of both, the bacterial luminescence emission as well as the growth in the modified LBT. In the umu-test no significant induction of the umuC gene as an indicator of genotoxicity was observed. Our results show that UV irradiation of GAB containing water would lead to the formation of recalcitrant PTPs. Considering that GAB was found in raw drinking water, the formation of toxic PTPs during drinking water treatment with UV light might be possible. Therefore, further studies should be conducted regarding the fate and effects on human health and the environment of GAB and the PTPs identified within this study. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Characterizing the magnetic memory signals on the surface of plasma transferred arc cladding coating under fatigue loads

    NASA Astrophysics Data System (ADS)

    Huang, Haihong; Han, Gang; Qian, Zhengchun; Liu, Zhifeng

    2017-12-01

    The metal magnetic memory signals were measured during dynamic tension tests on the surfaces of the cladding coatings by plasma transferred arc (PTA) welding and the 0.45% C steel. Results showed that the slope of the normal component Hp(y) of magnetic signal and the average value of the tangential component Hp(x) reflect the magnetization of the specimens. The signals increased sharply in the few initial cycles; and then fluctuated around a constant value during fatigue process until fracture. For the PTA cladding coating, the slope of Hp(y) was steeper and the average of Hp(x) was smaller, compared with the 0.45% C steel. The hysteresis curves of cladding layer, bonding layer and substrate were measured by vibrating sample magnetometer testing, and then saturation magnetization, initial susceptibility and coercivity were further calculated. The stress-magnetization curves were also plotted based on the J-A model, which showed that the PTA cladding coating has smaller remanence and coercivity compared with the 0.45% C steel. The microstructures of cladding coating confirmed that the dendritic structure and second-phase of alloy hinder the magnetic domain motion, which was the main factor influencing the variation of magnetic signal during the fatigue tests.

  13. Retention of Implicit Sequence Learning in Persons who Stutter and Persons with Parkinson's Disease

    PubMed Central

    Smits-Bandstra, Sarah; Gracco, Vincent

    2014-01-01

    This study investigated the retention of implicit sequence learning in 14 persons with Parkinson's disease (PPD), 14 persons who stutter (PWS) and 14 control participants. Participants completed a nonsense syllable serial reaction time task in a 120-minute session. Participants named aloud four syllables in response to four visual stimuli. The syllables formed a repeating 8-item sequence not made known to participants. After one week, participants completed a 60-minute retention session that included an explicit learning questionnaire and a sequence generation task. PPD showed retention of general learning equivalent to controls but PWS's reaction times were significantly slower on early trials of the retention test relative to other groups. Controls showed implicit learning during the initial session that was retained on the retention test. In contrast, PPD and PWS did not demonstrate significant implicit learning until the retention test suggesting intact, but delayed, learning and retention of implicit sequencing skills. All groups demonstrated similar limited explicit sequence knowledge. Performance differences between PWS and PPD relative to controls during the initial session and on early retention trials indicated possible dysfunction of the cortico-striato-thalamo-cortical loop. The etiological implications for stuttering, and clinical implications for both populations, of this dysfunction are discussed. PMID:23844763

  14. Promoting learning, memory, and transfer in a time-constrained, high hazard environment.

    PubMed

    Molesworth, Brett R C; Bennett, Lauren; Kehoe, E James

    2011-05-01

    Two methods of metacognitive reflection for promoting compliance with an aviation safety rule were tested in a transfer design. Two groups of pilots (n = 10) conducted a simulated flight entailing a search for a target on the ground. During this flight, only 35% of the pilots stayed above an altitude of 500 ft, the minimum allowed by relevant regulations. Following the flight, one group completed a self-explanation questionnaire, in which they explained their actions during the initial flight and what they would do in future flights. The other group completed a relapse-prevention questionnaire, in which they identified the circumstances leading to safety lapses and their future avoidance. A third group (n = 10) formed a rest control; they conducted a familiarization flight without a ground target or debriefing. One week later, all pilots conducted a series of test flights with the same or different ground targets as the initial flight. The self-explanation group showed 100% compliance when the ground target remained the same, but less so (<70%) when the ground target was different. The relapse-prevention group and control groups both showed low levels of compliance across all test flights (<30%). The results are discussed from theoretical and applied perspectives. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. 10 CFR 26.131 - Cutoff levels for validity screening and initial validity tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Cutoff levels for validity screening and initial validity tests. 26.131 Section 26.131 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.131 Cutoff levels for validity screening and initial validity tests. (a) Each...

  16. 10 CFR 26.131 - Cutoff levels for validity screening and initial validity tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Cutoff levels for validity screening and initial validity tests. 26.131 Section 26.131 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.131 Cutoff levels for validity screening and initial validity tests. (a) Each...

  17. A Rare Presentation of the Syndrome of Inappropriate Antidiuretic Hormone in a 12-Year-Old Girl as the Initial Presentation of an Immature Ovarian Teratoma.

    PubMed

    Iqbal, Anoop Mohamed; Schwenk, W Frederick

    2018-02-01

    Immature ovarian teratoma is very rare in childhood. We report on a 12-year-old girl with immature ovarian teratoma who presented initially with syndrome of inappropriate antidiuretic hormone. A 12-year-old girl presented with acute abdomen and distention. Initial laboratory tests showed hyponatremia (sodium, 123 mmol/L), that did not respond to fluid management. Computed tomography imaging showed a 15 cm × 9 cm × 20 cm mass in the right ovary with multifocal internal fat, and dystrophic calcifications. She underwent exploratory laparotomy with a right salpingo-oophorectomy, omentectomy, and peritoneal stripping. The pathology revealed metastatic immature teratoma. Hyponatremia resolved soon after the surgery. Although a rare diagnosis, immature ovarian teratoma must be considered in a girl who presents with abdominal mass and hyponatremia. Copyright © 2017 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  18. Test results of the Chrysler upgraded automotive gas turbine engine: Initial design

    NASA Technical Reports Server (NTRS)

    Horvath, D.; Ribble, G. H., Jr.; Warren, E. L.; Wood, J. C.

    1981-01-01

    The upgraded engine as built to the original design was deficient in power and had excessive specific fuel consumption. A high instrumented version of the engine was tested to identify the sources of the engine problems. Analysis of the data shows the major problems to be low compressor and power turbine efficiency and excessive interstage duct losses. In addition, high HC and CO emission were measured at idle, and high NOx emissions at high energy speeds.

  19. Initial High-Power-CW-Laser Testing of Liquid-Crystal Optical Phased Arrays

    DTIC Science & Technology

    2010-02-01

    During testing, the pump was operated in its "turbo" mode. The temperature was monitored by one of two devices: an Omega HH82 digital...could be investigated. The bar was controlled by an Omega CN76000 temperature controller. The temperature was monitored by the same two devices used...increased. The traces in figure 6 show the phase modulation come back to life as the power was then lowered to 20 watts, 10 watts, and after

  20. Associations between Mode of HIV Testing and Consent, Confidentiality, and Referral: A Comparative Analysis in Four African Countries

    PubMed Central

    Obermeyer, Carla Makhlouf; Neuman, Melissa; Desclaux, Alice; Wanyenze, Rhoda; Ky-Zerbo, Odette; Cherutich, Peter; Namakhoma, Ireen; Hardon, Anita

    2012-01-01

    Background Recommendations about scaling up HIV testing and counseling highlight the need to provide key services and to protect clients' rights, but it is unclear to what extent different modes of testing differ in this respect. This paper examines whether practices regarding consent, confidentiality, and referral vary depending on whether testing is provided through voluntary counseling and testing (VCT) or provider-initiated testing. Methods and Findings The MATCH (Multi-Country African Testing and Counseling for HIV) study was carried out in Burkina Faso, Kenya, Malawi, and Uganda. Surveys were conducted at selected facilities. We defined eight outcome measures related to pre- and post-test counseling, consent, confidentiality, satisfactory interactions with providers, and (for HIV-positive respondents) referral for care. These were compared across three types of facilities: integrated facilities, where testing is provided along with medical care; stand-alone VCT facilities; and prevention of mother-to-child transmission (PMTCT) facilities, where testing is part of PMTCT services. Tests of bivariate associations and modified Poisson regression were used to assess significance and estimate the unadjusted and adjusted associations between modes of testing and outcome measures. In total, 2,116 respondents tested in 2007 or later reported on their testing experience. High percentages of clients across countries and modes of testing reported receiving recommended services and being satisfied. In the unadjusted analyses, integrated testers were less likely to meet with a counselor before testing (83% compared with 95% of VCT testers; p<0.001), but those who had a pre-test meeting were more likely to have completed consent procedures (89% compared with 83% among VCT testers; p<0.001) and pre-test counseling (78% compared with 73% among VCT testers; p = 0.015). Both integrated and PMTCT testers were more likely to receive complete post-test counseling than were VCT testers (59% among both PMTCT and integrated testers compared with 36% among VCT testers; p<0.001). Adjusted analyses by country show few significant differences by mode of testing: only lower satisfaction among integrated testers in Burkina Faso and Uganda, and lower frequency of referral among PMTCT testers in Malawi. Adjusted analyses of pooled data across countries show a higher likelihood of pre-test meeting for those testing at VCT facilities (adjusted prevalence ratio: 1.22, 95% CI: 1.07–1.38) and higher satisfaction for stand-alone VCT facilities (adjusted prevalence ratio: 1.15; 95% CI: 1.06–1.25), compared to integrated testing, but no other associations were statistically significant. Conclusions Overall, in this study most respondents reported favorable outcomes for consent, confidentiality, and referral. Provider-initiated ways of delivering testing and counseling do not appear to be associated with less favorable outcomes for clients than traditional, client-initiated VCT, suggesting that testing can be scaled up through multiple modes without detriment to clients' rights. Please see later in the article for the Editors' Summary PMID:23109914

  1. Associations between mode of HIV testing and consent, confidentiality, and referral: a comparative analysis in four African countries.

    PubMed

    Obermeyer, Carla Makhlouf; Neuman, Melissa; Desclaux, Alice; Wanyenze, Rhoda; Ky-Zerbo, Odette; Cherutich, Peter; Namakhoma, Ireen; Hardon, Anita

    2012-01-01

    Recommendations about scaling up HIV testing and counseling highlight the need to provide key services and to protect clients' rights, but it is unclear to what extent different modes of testing differ in this respect. This paper examines whether practices regarding consent, confidentiality, and referral vary depending on whether testing is provided through voluntary counseling and testing (VCT) or provider-initiated testing. The MATCH (Multi-Country African Testing and Counseling for HIV) study was carried out in Burkina Faso, Kenya, Malawi, and Uganda. Surveys were conducted at selected facilities. We defined eight outcome measures related to pre- and post-test counseling, consent, confidentiality, satisfactory interactions with providers, and (for HIV-positive respondents) referral for care. These were compared across three types of facilities: integrated facilities, where testing is provided along with medical care; stand-alone VCT facilities; and prevention of mother-to-child transmission (PMTCT) facilities, where testing is part of PMTCT services. Tests of bivariate associations and modified Poisson regression were used to assess significance and estimate the unadjusted and adjusted associations between modes of testing and outcome measures. In total, 2,116 respondents tested in 2007 or later reported on their testing experience. High percentages of clients across countries and modes of testing reported receiving recommended services and being satisfied. In the unadjusted analyses, integrated testers were less likely to meet with a counselor before testing (83% compared with 95% of VCT testers; p<0.001), but those who had a pre-test meeting were more likely to have completed consent procedures (89% compared with 83% among VCT testers; p<0.001) and pre-test counseling (78% compared with 73% among VCT testers; p = 0.015). Both integrated and PMTCT testers were more likely to receive complete post-test counseling than were VCT testers (59% among both PMTCT and integrated testers compared with 36% among VCT testers; p<0.001). Adjusted analyses by country show few significant differences by mode of testing: only lower satisfaction among integrated testers in Burkina Faso and Uganda, and lower frequency of referral among PMTCT testers in Malawi. Adjusted analyses of pooled data across countries show a higher likelihood of pre-test meeting for those testing at VCT facilities (adjusted prevalence ratio: 1.22, 95% CI: 1.07-1.38) and higher satisfaction for stand-alone VCT facilities (adjusted prevalence ratio: 1.15; 95% CI: 1.06-1.25), compared to integrated testing, but no other associations were statistically significant. Overall, in this study most respondents reported favorable outcomes for consent, confidentiality, and referral. Provider-initiated ways of delivering testing and counseling do not appear to be associated with less favorable outcomes for clients than traditional, client-initiated VCT, suggesting that testing can be scaled up through multiple modes without detriment to clients' rights. Please see later in the article for the Editors' Summary.

  2. Acyclovir resistance in herpes simplex virus type I encephalitis: a case report.

    PubMed

    Bergmann, M; Beer, R; Kofler, M; Helbok, R; Pfausler, B; Schmutzhard, E

    2017-04-01

    Acyclovir resistance is rarely seen in herpes simplex virus (HSV) type I encephalitis. Prevalence rates vary between 0.5 % in immunocompetent patients (Christophers et al. 1998; Fife et al. 1994) and 3.5-10 % in immunocompromised patients (Stranska et al. 2005). We report a 45-year-old, immunocompetent (negative HIV antigen/antibody testing), female patient, without previous illness who developed-after a febrile prodromal stage-aphasia and psychomotor slowing. Cerebral magnetic resonance imaging (cMRI) showed right temporal and insular T2-hyperintense lesions with spreading to the contralateral temporal lobe. Cerebrospinal fluid (CSF) analysis yielded lymphocytic pleocytosis and elevated protein level. Polymerase chain reaction testing for HSV type I showed a positive result in repeat lumbar puncture. HSV type I encephalitis was diagnosed and intravenous acyclovir treatment was initiated (750 mg t.i.d.). Acyclovir treatment was intensified to 1000 mg t.i.d., due to clinical deterioration, ongoing pleocytosis and progression on cMRI 5 days after initiation of antiviral therapy. In parallel, acyclovir resistance testing showed mutation of thymidine kinase gene at position A156V prompting foscarnet therapy (60 mg t.i.d.). Patient's condition improved dramatically over 2 weeks. Acyclovir resistance is rare but should be considered in case of clinical worsening of patient's condition. To our knowledge, this is the first report of acyclovir resistance in HSV type I encephalitis of an immunocompetent and previously healthy patient in Austria.

  3. On the use of external burning to reduce aerospace vehicle transonic drag

    NASA Technical Reports Server (NTRS)

    Trefny, Charles J.

    1990-01-01

    The external combustion of hydrogen to reduce the transonic drag of aerospace vehicles is currently being investigated. A preliminary analysis based on a constant pressure control volume is discussed. Results indicate that the specific impulse of the external burning process rivals that of a turbojet and depends on the severity of the initial base drag as well as on the Mach flight number and the equivalence ratio. A test program was conducted to investigate hydrogen-air flame stability at the conditions of interest and to demonstrate drag reduction on a simple expansion ramp. Initial test results are presented and compared with the control-volume analysis. The expansion ramp surface pressure coefficient showed little variation with fuel pressure and altitude, in disagreement with the analysis. Flame stability results were encouraging and indicate that stable combustion is possible over an adequate range of conditions. Facility interference and chemical kinetics phenomena that make interpretation of subscale ground test data difficult are discussed.

  4. Geochemical anomalies from bottom ash in a road construction--comparison of the leaching potential between an ash road and the surroundings.

    PubMed

    Lind, Bo B; Norrman, Jenny; Larsson, Lennart B; Ohlsson, Sten-Ake; Bristav, Henrik

    2008-01-01

    A study was performed between June 2001 and December 2004 with the primary objective of assessing long-term leaching from municipal solid waste incineration bottom ash in a test road construction in relation to a reference road made up of conventional materials and the natural geochemical conditions in the surroundings. The metal leaching from the test road and the reference road was compared with the natural weathering in the regional surroundings for three time scales: 16, 80 and 1000 years. The results show that Cu and Zn cause a geochemical anomaly from the test road compared with the surroundings. The leaching of Cu from the test road is initially high but will decline with time and will in the long term be exceeded by natural weathering. Zn on the other hand has low initial leaching, which will increase with time and will in the long term exceed that of the test road and the surroundings by a factor of 100-300. For the other metals studied, Al, Na, K and Mg, there is only very limited leaching over time and the potential accumulation will not exceed the background values in a 1000 years.

  5. Comparison of Taxi Time Prediction Performance Using Different Taxi Speed Decision Trees

    NASA Technical Reports Server (NTRS)

    Lee, Hanbong

    2017-01-01

    In the STBO modeler and tactical surface scheduler for ATD-2 project, taxi speed decision trees are used to calculate the unimpeded taxi times of flights taxiing on the airport surface. The initial taxi speed values in these decision trees did not show good prediction accuracy of taxi times. Using the more recent, reliable surveillance data, new taxi speed values in ramp area and movement area were computed. Before integrating these values into the STBO system, we performed test runs using live data from Charlotte airport, with different taxi speed settings: 1) initial taxi speed values and 2) new ones. Taxi time prediction performance was evaluated by comparing various metrics. The results show that the new taxi speed decision trees can calculate the unimpeded taxi-out times more accurately.

  6. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  7. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  8. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  9. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  10. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  11. Tradeoffs in Acceleration and Initialization of Superparameterized Global Atmospheric Models for MJO and Climate Science

    NASA Astrophysics Data System (ADS)

    Pritchard, M. S.; Bretherton, C. S.; DeMott, C. A.

    2014-12-01

    New trade-offs are discussed in the cloud superparameterization approach to explicitly representing deep convection in global climate models. Intrinsic predictability tests show that the memory of cloud-resolving-scale organization is not critical for producing desired modes of organized convection such as the Madden-Julian Oscillation (MJO). This has implications for the feasibility of data assimilation and real-world initialization for superparameterized weather forecasting. Climate simulation sensitivity tests demonstrate that 400% acceleration of cloud superparameterization is possible by restricting the 32-128 km scale regime without deteriorating the realism of the simulated MJO but the number of cloud resolving model grid columns is discovered to constrain the efficiency of vertical mixing, with consequences for the simulated liquid cloud climatology. Tuning opportunities for next generation accelerated superparameterized climate models are discussed.

  12. A submillimeter tripler using a quasi-waveguide structure

    NASA Technical Reports Server (NTRS)

    Erickson, Neal R.; Cortes-Medellin, German

    1992-01-01

    A new type of frequency multiplier structure is being developed which is suitable for application at frequencies above 1 THz. This structure preserves some of the properties of waveguide for mode control, yet is not truly single mode. The device resembles a sectoral horn, with a varactor diode mounted near the throat. Input and output coupling are through the same aperture, requiring a quasi-optical diplexer. Initial tests are directed at building a tripler at 500 GHz, for comparison with waveguide structures. The diplexer is a blazed diffraction grating with appropriate focusing optics. Model studies show that the impedance match to a varactor should be good, and initial tests of the beam patterns of the prototype indicate that optical coupling efficiency should be very high. The structure also has the potential for use as a fundamental mixer, or as a third harmonic mixer.

  13. A kinematic analysis of the rapid step test in balance-impaired and unimpaired older women.

    PubMed

    Schulz, Brian W; Ashton-Miller, James A; Alexander, Neil B

    2007-04-01

    Little is known about the kinematic and kinetic determinants that might explain age and balance-impairment alterations in the results of volitional stepping performance tests. Maximal unipedal stance time (UST) was used to distinguish "balance-impaired" old (BI, UST<10s, N=15, mean age=76 years) from unimpaired old (O, UST>30s, N=12, mean age=71 years) before they and healthy young females (Y, UST>30s, N=13, mean age=23 years) performed the rapid step test (RST). The RST evaluates the time required to take volitional front, side, and back steps of at least 80% maximum step length in response to verbal commands. Kinematic and kinetic data were recorded during the RST. The results indicate that the initiation phase of the step was the major source of age- and balance impairment-related delays. The delays in BI were primarily caused by increased postural adjustments prior to step initiation, as measured by center-of-pressure (COP) path length (p<0.003). The Step landing phase showed similar, but non-significant, temporal trends. Step length and peak center-of-mass (COM) deceleration during the Step-Out landing decreased in O by 18% (p=0.0002) and 24% (p=0.001), respectively, and a further 12% (p=0.04) and 18% (p=0.08) in BI. We conclude that the delay in BI step initiation was due to the increase in their postural adjustments prior to step initiation.

  14. Evidence for deterministic chaos in aperiodic oscillations of acute lymphoblastic leukemia cells in long-term culture

    NASA Astrophysics Data System (ADS)

    Lambrou, George I.; Chatziioannou, Aristotelis; Vlahopoulos, Spiros; Moschovi, Maria; Chrousos, George P.

    Biological systems are dynamic and possess properties that depend on two key elements: initial conditions and the response of the system over time. Conceptualizing this on tumor models will influence conclusions drawn with regard to disease initiation and progression. Alterations in initial conditions dynamically reshape the properties of proliferating tumor cells. The present work aims to test the hypothesis of Wolfrom et al., that proliferation shows evidence for deterministic chaos in a manner such that subtle differences in the initial conditions give rise to non-linear response behavior of the system. Their hypothesis, tested on adherent Fao rat hepatoma cells, provides evidence that these cells manifest aperiodic oscillations in their proliferation rate. We have tested this hypothesis with some modifications to the proposed experimental setup. We have used the acute lymphoblastic leukemia cell line CCRF-CEM, as it provides an excellent substrate for modeling proliferation dynamics. Measurements were taken at time points varying from 24h to 48h, extending the assayed populations beyond that of previous published reports that dealt with the complex dynamic behavior of animal cell populations. We conducted flow cytometry studies to examine the apoptotic and necrotic rate of the system, as well as DNA content changes of the cells over time. The cells exhibited a proliferation rate of nonlinear nature, as this rate presented oscillatory behavior. The obtained data have been fit in known models of growth, such as logistic and Gompertzian growth.

  15. Rapid conversion of an oceanic spreading center to a subduction zone inferred from high-precision geochronology.

    PubMed

    Keenan, Timothy E; Encarnación, John; Buchwaldt, Robert; Fernandez, Dan; Mattinson, James; Rasoazanamparany, Christine; Luetkemeyer, P Benjamin

    2016-11-22

    Where and how subduction zones initiate is a fundamental tectonic problem, yet there are few well-constrained geologic tests that address the tectonic settings and dynamics of the process. Numerical modeling has shown that oceanic spreading centers are some of the weakest parts of the plate tectonic system [Gurnis M, Hall C, Lavier L (2004) Geochem Geophys Geosys 5:Q07001], but previous studies have not favored them for subduction initiation because of the positive buoyancy of young lithosphere. Instead, other weak zones, such as fracture zones, have been invoked. Because these models differ in terms of the ages of crust that are juxtaposed at the site of subduction initiation, they can be tested by dating the protoliths of metamorphosed oceanic crust that is formed by underthrusting at the beginning of subduction and comparing that age with the age of the overlying lithosphere and the timing of subduction initiation itself. In the western Philippines, we find that oceanic crust was less than ∼1 My old when it was underthrust and metamorphosed at the onset of subduction in Palawan, Philippines, implying forced subduction initiation at a spreading center. This result shows that young and positively buoyant, but weak, lithosphere was the preferred site for subduction nucleation despite the proximity of other potential weak zones with older, denser lithosphere and that plate motion rapidly changed from divergence to convergence.

  16. Initiation of Swarming Motility by Proteus mirabilis Occurs in Response to Specific Cues Present in Urine and Requires Excess l-Glutamine

    PubMed Central

    Armbruster, Chelsie E.; Hodges, Steven A.

    2013-01-01

    Proteus mirabilis, a leading cause of catheter-associated urinary tract infection (CaUTI), differentiates into swarm cells that migrate across catheter surfaces and medium solidified with 1.5% agar. While many genes and nutrient requirements involved in the swarming process have been identified, few studies have addressed the signals that promote initiation of swarming following initial contact with a surface. In this study, we show that P. mirabilis CaUTI isolates initiate swarming in response to specific nutrients and environmental cues. Thirty-three compounds, including amino acids, polyamines, fatty acids, and tricarboxylic acid (TCA) cycle intermediates, were tested for the ability to promote swarming when added to normally nonpermissive media. l-Arginine, l-glutamine, dl-histidine, malate, and dl-ornithine promoted swarming on several types of media without enhancing swimming motility or growth rate. Testing of isogenic mutants revealed that swarming in response to the cues required putrescine biosynthesis and pathways involved in amino acid metabolism. Furthermore, excess glutamine was found to be a strict requirement for swarming on normal swarm agar in addition to being a swarming cue under normally nonpermissive conditions. We thus conclude that initiation of swarming occurs in response to specific cues and that manipulating concentrations of key nutrient cues can signal whether or not a particular environment is permissive for swarming. PMID:23316040

  17. Rapid conversion of an oceanic spreading center to a subduction zone inferred from high-precision geochronology

    PubMed Central

    Keenan, Timothy E.; Encarnación, John; Buchwaldt, Robert; Fernandez, Dan; Mattinson, James; Rasoazanamparany, Christine; Luetkemeyer, P. Benjamin

    2016-01-01

    Where and how subduction zones initiate is a fundamental tectonic problem, yet there are few well-constrained geologic tests that address the tectonic settings and dynamics of the process. Numerical modeling has shown that oceanic spreading centers are some of the weakest parts of the plate tectonic system [Gurnis M, Hall C, Lavier L (2004) Geochem Geophys Geosys 5:Q07001], but previous studies have not favored them for subduction initiation because of the positive buoyancy of young lithosphere. Instead, other weak zones, such as fracture zones, have been invoked. Because these models differ in terms of the ages of crust that are juxtaposed at the site of subduction initiation, they can be tested by dating the protoliths of metamorphosed oceanic crust that is formed by underthrusting at the beginning of subduction and comparing that age with the age of the overlying lithosphere and the timing of subduction initiation itself. In the western Philippines, we find that oceanic crust was less than ∼1 My old when it was underthrust and metamorphosed at the onset of subduction in Palawan, Philippines, implying forced subduction initiation at a spreading center. This result shows that young and positively buoyant, but weak, lithosphere was the preferred site for subduction nucleation despite the proximity of other potential weak zones with older, denser lithosphere and that plate motion rapidly changed from divergence to convergence. PMID:27821756

  18. Increases in Recent HIV Testing Among Men Who Have Sex With Men Coincide With the Centers for Disease Control and Prevention's Expanded Testing Initiative

    PubMed Central

    Cooley, Laura A.; Wejnert, Cyprian; Rose, Charles E.; Paz-Bailey, Gabriela; Taussig, Jennifer; Gern, Robert; Hoyte, Tamika; Salazar, Laura; White, Jianglan; Todd, Jeff; Bautista, Greg; Flynn, Colin; Sifakis, Frangiscos; German, Danielle; Isenberg, Debbie; Driscoll, Maura; Hurwitz, Elizabeth; Doherty, Rose; Wittke, Chris; Prachand, Nikhil; Benbow, Nanette; Melville, Sharon; Pannala, Praveen; Yeager, Richard; Sayegh, Aaron; Dyer, Jim; Sheu, Shane; Novoa, Alicia; Thrun, Mark; Al-Tayyib, Alia; Wilmoth, Ralph; Higgins, Emily; Griffin, Vivian; Mokotoff, Eve; MacMaster, Karen; Wolverton, Marcia; Risser, Jan; Rehman, Hafeez; Padgett, Paige; Bingham, Trista; Sey, Ekow Kwa; LaLota, Marlene; Metsch, Lisa; Forrest, David; Beck, Dano; Cardenas, Gabriel; Nemeth, Chris; Anderson, Bridget J.; Watson, Carol-Ann; Smith, Lou; Robinson, William T.; Gruber, DeAnn; Barak, Narquis; Murrill, Chris; Neaigus, Alan; Jenness, Samuel; Hagan, Holly; Reilly, Kathleen H.; Wendel, Travis; Cross, Helene; Bolden, Barbara; D'Errico, Sally; Wogayehu, Afework; Godette, Henry; Brady, Kathleen A.; Kirkland, Althea; Sifferman, Andrea; Miguelino-Keasling, Vanessa; Velasco, Al; Tovar, Veronica; Raymond, H. Fisher; De León, Sandra Miranda; Rolón-Colón, Yadira; Marzan, Melissa; Courogen, Maria; Jaenicke, Tom; Thiede, Hanne; Burt, Richard; Jia, Yujiang; Opoku, Jenevieve; Sansone, Marie; West, Tiffany; Magnus, Manya; Kuo, Irene

    2015-01-01

    According to National HIV Behavioral Surveillance system data, human immunodeficiency virus (HIV) testing increased among gay, bisexual, and other men who have sex with men from 2008 to 2011 in cities funded by the Centers for Disease Control and Prevention's Expanded Testing Initiative, suggesting that focused HIV testing initiatives might have positive effects. PMID:25352589

  19. Liquid Oxygen Propellant Densification Production and Performance Test Results With a Large-Scale Flight-Weight Propellant Tank for the X33 RLV

    NASA Technical Reports Server (NTRS)

    Tomsik, Thomas M.; Meyer, Michael L.

    2010-01-01

    This paper describes in-detail a test program that was initiated at the Glenn Research Center (GRC) involving the cryogenic densification of liquid oxygen (LO2). A large scale LO2 propellant densification system rated for 200 gpm and sized for the X-33 LO2 propellant tank, was designed, fabricated and tested at the GRC. Multiple objectives of the test program included validation of LO2 production unit hardware and characterization of densifier performance at design and transient conditions. First, performance data is presented for an initial series of LO2 densifier screening and check-out tests using densified liquid nitrogen. The second series of tests show performance data collected during LO2 densifier test operations with liquid oxygen as the densified product fluid. An overview of LO2 X-33 tanking operations and load tests with the 20,000 gallon Structural Test Article (STA) are described. Tank loading testing and the thermal stratification that occurs inside of a flight-weight launch vehicle propellant tank were investigated. These operations involved a closed-loop recirculation process of LO2 flow through the densifier and then back into the STA. Finally, in excess of 200,000 gallons of densified LO2 at 120 oR was produced with the propellant densification unit during the demonstration program, an achievement that s never been done before in the realm of large-scale cryogenic tests.

  20. Prospective patients rate practice factors: development of a questionnaire.

    PubMed

    St Louis, Brian Lingg; Firestone, Allen R; Johnston, William; Shanker, Shiva; Vig, Katherine W L

    2011-02-01

    The importance that prospective patients place on practice characteristics when choosing an orthodontic practice has not been extensively reported. The objective of this research was to develop a valid and reliable questionnaire to address the relative importance of orthodontic office and doctor characteristics for prospective patients or parents of child patients during the initial orthodontic office consultation. An initial questionnaire, based on published literature, was field-tested on 16 subjects to assess its validity. Based on the field test, the questionnaire was modified and tested for reliability by using a test-retest method. The questionnaire covered the following areas: doctor, office, staff, and finances. The reliability study included 2 groups of subjects: 12 consecutive prospective adult patients and 41 consecutive parents of prospective child patients. The questionnaires consisted of 43 and 50 questions for the adult patients and the parents of patients, respectively. The subjects rated the importance of practice characteristics in their selection of an orthodontic practice using a 100-mm visual analog scale anchored at "not important at all" and "most important." Reliability was analyzed by using the intraclass correlation coefficient (ICC). Summary scores of all 53 subjects showed excellent reliability (ICC, 0.88; range, 0.61-1.0). Summary scores of all 50 questions showed acceptable reliability (ICC, 0.70; range, 0.45-0.88). Twenty-one questions had excellent reliability (ICC, >.75), and 29 questions had fair-to-good reliability (ICC, 0.41-0.75). No questions showed poor reliability (ICC, <0.4). The pilot study data indicated that the overall reliability of the questionnaire is acceptable. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  1. Multi-parameter Observations and Validation of Pre-earthquake Atmospheric Signals

    NASA Astrophysics Data System (ADS)

    Ouzounov, D.; Pulinets, S. A.; Hattori, K.; Mogi, T.; Kafatos, M.

    2014-12-01

    We are presenting the latest development in multi-sensors observations of short-term pre-earthquake phenomena preceding major earthquakes. We are exploring the potential of pre-seismic atmospheric and ionospheric signals to alert for large earthquakes. To achieve this, we start validating anomalous ionospheric /atmospheric signals in retrospective and prospective modes. The integrated satellite and terrestrial framework (ISTF) is our method for validation and is based on a joint analysis of several physical and environmental parameters (Satellite thermal infrared radiation (OLR), electron concentration in the ionosphere (GPS/TEC), VHF-bands radio waves, radon/ion activities, air temperature and seismicity patterns) that were found to be associated with earthquakes. The science rationale for multidisciplinary analysis is based on concept Lithosphere-Atmosphere-Ionosphere Coupling (LAIC) [Pulinets and Ouzounov, 2011], which explains the synergy of different geospace processes and anomalous variations, usually named short-term pre-earthquake anomalies. Our validation processes consist in two steps: (1) A continuous retrospective analysis preformed over two different regions with high seismicity- Taiwan and Japan for 2003-2009 The retrospective tests (100+ major earthquakes, M>5.9, Taiwan and Japan) show OLR anomalous behavior before all of these events with no false negatives. False alarm ratio for false positives is less then 25%. (2) Prospective testing using multiple parameters with potential for M5.5+ events. The initial testing shows systematic appearance of atmospheric anomalies in advance (days) to the M5.5+ events for Taiwan and Japan (Honshu and Hokkaido areas). Our initial prospective results suggest that our approach show a systematic appearance of atmospheric anomalies, one to several days prior to the largest earthquakes That feature could be further studied and tested for advancing the multi-sensors detection of pre-earthquake atmospheric signals.

  2. The Incorporation and Initialization of Cloud Water/ice in AN Operational Forecast Model

    NASA Astrophysics Data System (ADS)

    Zhao, Qingyun

    Quantitative precipitation forecasts have been one of the weakest aspects of numerical weather prediction models. Theoretical studies show that the errors in precipitation calculation can arise from three sources: errors in the large-scale forecasts of primary variables, errors in the crude treatment of condensation/evaporation and precipitation processes, and errors in the model initial conditions. A new precipitation parameterization scheme has been developed to investigate the forecast value of improved precipitation physics via the introduction of cloud water and cloud ice into a numerical prediction model. The main feature of this scheme is the explicit calculation of cloud water and cloud ice in both the convective and stratiform precipitation parameterization. This scheme has been applied to the eta model at the National Meteorological Center. Four extensive tests have been performed. The statistical results showed a significant improvement in the model precipitation forecasts. Diagnostic studies suggest that the inclusion of cloud ice is important in transferring water vapor to precipitation and in the enhancement of latent heat release; the latter subsequently affects the vertical motion field significantly. Since three-dimensional cloud data is absent from the analysis/assimilation system for most numerical models, a method has been proposed to incorporate observed precipitation and nephanalysis data into the data assimilation system to obtain the initial cloud field for the eta model. In this scheme, the initial moisture and vertical motion fields are also improved at the same time as cloud initialization. The physical initialization is performed in a dynamical initialization framework that uses the Newtonian dynamical relaxation method to nudge the model's wind and mass fields toward analyses during a 12-hour data assimilation period. Results from a case study showed that a realistic cloud field was produced by this method at the end of the data assimilation period. Precipitation forecasts have been significantly improved as a result of the improved initial cloud, moisture and vertical motion fields.

  3. 14 CFR 33.90 - Initial maintenance inspection test.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Initial maintenance inspection test. 33.90 Section 33.90 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.90 Initial maintenance...

  4. 14 CFR 33.90 - Initial maintenance inspection test.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Initial maintenance inspection test. 33.90 Section 33.90 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.90 Initial maintenance...

  5. 14 CFR 33.90 - Initial maintenance inspection test.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Initial maintenance inspection test. 33.90 Section 33.90 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.90 Initial maintenance...

  6. 14 CFR 33.90 - Initial maintenance inspection test.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Initial maintenance inspection test. 33.90 Section 33.90 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.90 Initial maintenance...

  7. Model systems for defining initiation, promotion, and progression of skin neoplasms.

    PubMed

    Boutwell, R K

    1989-01-01

    A number of items that must be considered in designing and choosing a suitable model for initiation and promotion testing have been described. Although these items may seem complex, tests for initiation and promotion are, in reality, quite simple and provide a rational approach to carcinogen testing. Several tests have been described here and Eastin, elsewhere in this book, describes the validation of a simple and highly recommended test. The processes involved in initiation and promotion are qualitatively different. The criteria for concern about possible human hazards as well as for regulation of initiators and promoters should be based on these qualitative differences. Realistic appraisal of the risk must be based on the level and nature of the potential hazard. In particular, it must be recognized that promoting action is reversible, that a threshold exists, and that promotion is readily inhibited. Therefore, animal tests that differentiate between potential initiators and promoters are essential to enable a logical assessment of human risk and the implementation of appropriate protective measures based on scientific facts.

  8. Stress corrosion crack initiation of Zircaloy-4 cladding tubes in an iodine vapor environment during creep, relaxation, and constant strain rate tests

    NASA Astrophysics Data System (ADS)

    Jezequel, T.; Auzoux, Q.; Le Boulch, D.; Bono, M.; Andrieu, E.; Blanc, C.; Chabretou, V.; Mozzani, N.; Rautenberg, M.

    2018-02-01

    During accidental power transient conditions with Pellet Cladding Interaction (PCI), the synergistic effect of the stress and strain imposed on the cladding by thermal expansion of the fuel, and corrosion by iodine released as a fission product, may lead to cladding failure by Stress Corrosion Cracking (SCC). In this study, internal pressure tests were conducted on unirradiated cold-worked stress-relieved Zircaloy-4 cladding tubes in an iodine vapor environment. The goal was to investigate the influence of loading type (constant pressure tests, constant circumferential strain rate tests, or constant circumferential strain tests) and test temperature (320, 350, or 380 °C) on iodine-induced stress corrosion cracking (I-SCC). The experimental results obtained with different loading types were consistent with each other. The apparent threshold hoop stress for I-SCC was found to be independent of the test temperature. SEM micrographs of the tested samples showed many pits distributed over the inner surface, which tended to coalesce into large pits in which a microcrack could initiate. A model for the time-to-failure of a cladding tube was developed using finite element simulations of the viscoplastic mechanical behavior of the material and a modified Kachanov's damage growth model. The times-to-failure predicted by this model are consistent with the experimental data.

  9. Hypothesis testing for the validation of the kinetic spectrophotometric methods for the determination of lansoprazole in bulk and drug formulations via Fe(III) and Zn(II) chelates.

    PubMed

    Rahman, Nafisur; Kashif, Mohammad

    2010-03-01

    Point and interval hypothesis tests performed to validate two simple and economical, kinetic spectrophotometric methods for the assay of lansoprazole are described. The methods are based on the formation of chelate complex of the drug with Fe(III) and Zn(II). The reaction is followed spectrophotometrically by measuring the rate of change of absorbance of coloured chelates of the drug with Fe(III) and Zn(II) at 445 and 510 nm, respectively. The stoichiometric ratio of lansoprazole to Fe(III) and Zn(II) complexes were found to be 1:1 and 2:1, respectively. The initial-rate and fixed-time methods are adopted for determination of drug concentrations. The calibration graphs are linear in the range 50-200 µg ml⁻¹ (initial-rate method), 20-180 µg ml⁻¹ (fixed-time method) for lansoprazole-Fe(III) complex and 120-300 (initial-rate method), and 90-210 µg ml⁻¹ (fixed-time method) for lansoprazole-Zn(II) complex. The inter-day and intra-day precision data showed good accuracy and precision of the proposed procedure for analysis of lansoprazole. The point and interval hypothesis tests indicate that the proposed procedures are not biased. Copyright © 2010 John Wiley & Sons, Ltd.

  10. The Effects of Shot and Laser Peening on Fatigue Life and Crack Growth in 2024 Aluminum Alloy and 4340 Steel

    NASA Technical Reports Server (NTRS)

    Everett, R. A., Jr.; Matthews, W. T.; Prabhakaran, R.; Newman, J. C., Jr.; Dubberly, M. J.

    2001-01-01

    Fatigue and crack growth tests have been conducted on 4340 steel and 2024-T3 aluminum alloy, respectively, to assess the effects of shot peening on fatigue life and the effects of shot and laser peening on crack growth. Two current programs involving fixed and rotary-wing aircraft will not be using shot peened structures. Since the shot peening compressive residual stress depth is usually less than the 0.05-inch initial damage tolerance crack size, it is believed by some that shot peening should have no beneficial effects toward retarding crack growth. In this study cracks were initiated from an electronic-discharged machining flaw which was cycled to produce a fatigue crack of approximately 0.05-inches in length and then the specimens were peened. Test results showed that after peening the crack growth rates were noticeably slower when the cracks were fairly short for both the shot and laser peened specimens resulting in a crack growth life that was a factor of 2 to 4 times greater than the results of the average unpeened test. Once the cracks reached a length of approximately 0.1-inches the growth rates were about the same for the peened and unpeened specimens. Fatigue tests on 4340 steel showed that the endurance limit of a test specimen with a 0.002-inch-deep machining-like scratch was reduced by approximately 40 percent. However, if the "scratched" specimen was shot peened after inserting the scratch, the fatigue life returned to almost 100 percent of the unflawed specimens original fatigue life.

  11. Motor starting a Brayton cycle power conversion system using a static inverter

    NASA Technical Reports Server (NTRS)

    Curreri, J. S.; Edkin, R. A.; Kruchowy, R.

    1973-01-01

    The power conversion module of a 2- to 15-kWe Brayton engine was motor started using a three-phase, 400-hertz static inverter as the power source. Motor-static tests were conducted for initial gas loop pressures of 10, 14, and 17 N/sq cm (15, 20, and 25 psia) over a range of initial turbine inlet temperatures from 366 to 550 K (200 to 530 F). The data are presented to show the effects of temperature and pressure on the motor-start characteristics of the rotating unit. Electrical characteristics during motoring are also discussed.

  12. Ethanol-reinforced responding by AA and ANA rats following the sucrose-substitution initiation procedure.

    PubMed

    Files, F J; Denning, C E; Hyytia, P; Kiianmaa, K; Samson, H H

    1997-06-01

    Ethanol-reinforced responding was initiated in male AA and ANA rats using the sucrose-substitution procedure. Before the initiation procedure, a homecage, two-bottle preference test was conducted. The rats were then trained to respond on an Fixed-Ratio 1 schedule with sucrose reinforcement. Over sessions, ethanol was added gradually to the sucrose solution as the concentration of sucrose was reduced until 10% ethanol (v/v) alone functioned as the reinforcer for lever pressing. The schedule of reinforcement was then increased to Fixed-Ratio 4. Next, the ethanol concentration presented as the reinforcer was increased over weeks to 15%, 20%, 30%, and then returned to 10%. A second homecage test was then performed. The results showed that the AA and ANA lines differed significantly on preference and intake (g/kg) during the homecage preference tests. There was a significant increase in preference during the second homecage test. During sucrose substitution, initial large differences in responding were observed between the lines. When the ethanol concentration was increased, intake (grams per kilogram) increased for the AA line but not for the ANA line. These effects were a function of no change in responding by the AA rats as concentration was increased and a decrease in responding by the ANA rats at the higher concentrations (20% and 30%). Taken together, data indicate that ethanol can function as a positive reinforcer for the behavior of AA and ANA rats. Even though 10% ethanol functioned as a reinforcer similarly for the two lines, ethanol intake in the AA line was significantly greater at the higher concentrations of ethanol, suggesting that ethanol functioned as a qualitatively different reinforcer for the AA rats, compared with the ANA rats.

  13. Does the delivery of diagnostic news affect the likelihood of whether or not patients ask questions about the results? A conversation analytical study.

    PubMed

    Murtagh, Ged M; Thomas, Anne L; Furber, Lynn

    2018-05-03

    Asymmetries in knowledge and competence in the medical encounter often mean that doctor-patient communication can be compromised. This study explores this issue and examines whether the likelihood of patient question asking is increased following the delivery of diagnostic test results. It also examines whether that likelihood is related to the way in which the test results are delivered. To examine when and how patients initiate questions following diagnostic news announcements. We audio-recorded oncology consultations (n = 47) consisting of both first consultations and follow-up consultations with patients with different types of cancer, at a leading UK teaching hospital. From the primary sample, we identified 30 consultations based on a basic count of the frequency of patient questions and their positioning in relation to diagnostic announcements. This subset of 30 consultations consisted of a mix of first and follow-up consultations. Our data demonstrate how the design and delivery of diagnostic news announcements can either discourage or provide the opportunity for a patient-initiated question in the next turn of talk. We identified two types of announcement. Q+ generally provided for a patient-initiated question as a relevant next turn following the news announcement, whereas Q- did not. Q+ was sometimes followed up with the explanation of test results, which appeared to encourage further patient questions. The design and delivery of diagnostic news announcements can make a patient-initiated question more or less appropriate, in the next turn of talk. In addition, showing and explaining test results can encourage further opportunities for patients' questions. © 2018 The Authors. Health Expectations published by John Wiley & Sons Ltd.

  14. Antiphospholipid antibodies in children with systemic lupus erythematosus: a long-term clinical and laboratory follow-up status study from northwest India.

    PubMed

    Ahluwalia, Jasmina; Singh, Surjit; Naseem, Shano; Suri, Deepti; Rawat, Amit; Gupta, Anju; Masih, Joseph; Bose, Sunil

    2014-05-01

    We have previously shown that children with pediatric systemic lupus erythematosus (pSLE) have high incidence of anti-phospholipid antibodies (APLA) and reports suggest that presence of APLA can modify disease expression. While the frequency of APLA has been studied previously in adults with SLE, there is paucity of literature in children especially with regard to long-term follow-up. In the earlier study, we analyzed 27 pSLE patients for the prevalence of APLA; in the present study, we further reviewed the APLA status and its relation with clinical outcome of this cohort of patients over a further 7 year follow-up period. Out of the initial cohort of 27 patients, follow-up APLA testing was available in 21 patients who were tested for APLA at least once during this time. Seven (33.3 %) of these 21 patients were never positive for any of the APLA; 1 (4.8 %) was persistently positive; and 13 (61.9 %) were positive for APLA intermittently or at least once. Overall, APLA positivity for IgG, IgM anticardiolipin antibodies (ACA) and lupus anticoagulant (LA) was comparable, with positivity seen in 10 (47.6 %), 9 (42.9 %) and 9 (42.9 %) cases, respectively. Anti-β2 GP1 antibodies were tested in 11 patients on follow-up, of which 3 (27.3 %) showed positivity. In all, 10 (47.6 %) patients showed positivity for more than 1 APLA. Two (9.5 %) patients showed varying degrees of positivity for LA, ACA, and anti-β2 GP1 antibodies at different times, thereby showing the importance of checking for all APLAs at each time of testing. Out of these 21 patients, 3 (14.3 %) patients had thrombosis, and all 3 patients were positive for APLA. There were 2 (9.5 %) fatalities-both of these had thrombosis and were positive for APLA. Our study shows that pSLE patients on treatment frequently test positive for APLA. Thrombosis was infrequent in this cohort. However, when present it was associated with APLA positivity and high fatality in our experience. On the other hand, presence or persistence of these antibodies was not always associated with thrombosis. Our study suggests that pSLE children should be tested routinely for APLA, as this would identify patients with an increased risk of thrombotic complications. However, the frequency of repeat testing for APLA in those who test negative initially needs to be determined on a case-to-case basis.

  15. Initiation and propagation of mixed mode fractures in granite and sandstone

    NASA Astrophysics Data System (ADS)

    Rück, Marc; Rahner, Roman; Sone, Hiroki; Dresen, Georg

    2017-10-01

    We investigate mixed mode fracture initiation and propagation in experimentally deformed granite and sandstone. We performed a series of asymmetric loading tests to induce fractures in cylindrical specimens at confining pressures up to 20 MPa. Loading was controlled using acoustic emission (AE) feedback control, which allows studying quasi-static fracture propagation for several hours. Location of acoustic emissions reveals distinct differences in spatial-temporal fracture evolution between granite and sandstone samples. Before reaching peak stress in experiments performed on granite, axial fractures initiate first at the edge of the indenter and then propagate through the entire sample. Secondary inclined fractures develop during softening of the sample. In sandstone, inclined shear fractures nucleate at peak stress and propagate through the specimen. AE source type analysis shows complex fracturing in both materials with pore collapse contributing significantly to fracture growth in sandstone samples. We compare the experimental results with numerical models to analyze stress distribution and energy release rate per unit crack surface area in the samples at different stages during fracture growth. We thereby show that for both rock types the energy release rate increases approximately linearly during fracture propagation. The study illuminates how different material properties modify fracture initiation direction under similar loading conditions.

  16. Mechanical Behaviour of Woven Graphite/Polyimide Composites with Medium and High Modulus Graphite Fibers Subjected to Biaxial Shear Dominated Loads

    NASA Technical Reports Server (NTRS)

    Kumose, M.; Gentz, M.; Rupnowski, P.; Armentrout, D.; Kumosa, L.; Shin, E.; Sutter, J. K.

    2003-01-01

    A major limitation of woven fiber/polymer matrix composite systems is the inability of these materials to resist intralaminar and interlaminar damage initiation and propagation under shear-dominated biaxial loading conditions. There are numerous shear test methods for woven fabric composites, each with its own advantages and disadvantages. Two techniques, which show much potential, are the Iosipescu shear and +/- 45 deg tensile tests. In this paper, the application of these two tests for the room and high temperature failure analyses of woven graphite/polyimide composites is briefly evaluated. In particular, visco-elastic micro, meso, and macro-stress distributions in a woven eight harness satin (8HS) T650/PMR-15 composite subjected to these two tests are presented and their effect on the failure process of the composite is evaluated. Subsequently, the application of the Iosipescu tests to the failure analysis of woven composites with medium (T650) and high (M40J and M60J) modulus graphite fibers and PMR-15 and PMR-II-50 polyimide resins is discussed. The composites were tested as-supplied and after thermal conditioning. The effect of temperature and thermal conditioning on the initiation of intralaminar damage and the shear strength of the composites was established.

  17. The development and validation of a test of science critical thinking for fifth graders.

    PubMed

    Mapeala, Ruslan; Siew, Nyet Moi

    2015-01-01

    The paper described the development and validation of the Test of Science Critical Thinking (TSCT) to measure the three critical thinking skill constructs: comparing and contrasting, sequencing, and identifying cause and effect. The initial TSCT consisted of 55 multiple choice test items, each of which required participants to select a correct response and a correct choice of critical thinking used for their response. Data were obtained from a purposive sampling of 30 fifth graders in a pilot study carried out in a primary school in Sabah, Malaysia. Students underwent the sessions of teaching and learning activities for 9 weeks using the Thinking Maps-aided Problem-Based Learning Module before they answered the TSCT test. Analyses were conducted to check on difficulty index (p) and discrimination index (d), internal consistency reliability, content validity, and face validity. Analysis of the test-retest reliability data was conducted separately for a group of fifth graders with similar ability. Findings of the pilot study showed that out of initial 55 administered items, only 30 items with relatively good difficulty index (p) ranged from 0.40 to 0.60 and with good discrimination index (d) ranged within 0.20-1.00 were selected. The Kuder-Richardson reliability value was found to be appropriate and relatively high with 0.70, 0.73 and 0.92 for identifying cause and effect, sequencing, and comparing and contrasting respectively. The content validity index obtained from three expert judgments equalled or exceeded 0.95. In addition, test-retest reliability showed good, statistically significant correlations ([Formula: see text]). From the above results, the selected 30-item TSCT was found to have sufficient reliability and validity and would therefore represent a useful tool for measuring critical thinking ability among fifth graders in primary science.

  18. A Discrete Event Simulation Model to Assess the Economic Value of a Hypothetical Pharmacogenomics Test for Statin-Induced Myopathy in Patients Initiating a Statin in Secondary Cardiovascular Prevention.

    PubMed

    Mitchell, Dominic; Guertin, Jason R; Dubois, Anick; Dubé, Marie-Pierre; Tardif, Jean-Claude; Iliza, Ange Christelle; Fanton-Aita, Fiorella; Matteau, Alexis; LeLorier, Jacques

    2018-04-01

    Statin (HMG-CoA reductase inhibitor) therapy is the mainstay dyslipidemia treatment and reduces the risk of a cardiovascular (CV) event (CVE) by up to 35%. However, adherence to statin therapy is poor. One reason patients discontinue statin therapy is musculoskeletal pain and the associated risk of rhabdomyolysis. Research is ongoing to develop a pharmacogenomics (PGx) test for statin-induced myopathy as an alternative to the current diagnosis method, which relies on creatine kinase levels. The potential economic value of a PGx test for statin-induced myopathy is unknown. We developed a lifetime discrete event simulation (DES) model for patients 65 years of age initiating a statin after a first CVE consisting of either an acute myocardial infarction (AMI) or a stroke. The model evaluates the potential economic value of a hypothetical PGx test for diagnosing statin-induced myopathy. We have assessed the model over the spectrum of test sensitivity and specificity parameters. Our model showed that a strategy with a perfect PGx test had an incremental cost-utility ratio of 4273 Canadian dollars ($Can) per quality-adjusted life year (QALY). The probabilistic sensitivity analysis shows that when the payer willingness-to-pay per QALY reaches $Can12,000, the PGx strategy is favored in 90% of the model simulations. We found that a strategy favoring patients staying on statin therapy is cost effective even if patients maintained on statin are at risk of rhabdomyolysis. Our results are explained by the fact that statins are highly effective in reducing the CV risk in patients at high CV risk, and this benefit largely outweighs the risk of rhabdomyolysis.

  19. Effect of Elevated Temperature and Loading Rate on Delamination Fracture Toughness

    NASA Technical Reports Server (NTRS)

    Reeder, J. R.; Allen, D. H.; Bradley, W. L.

    2003-01-01

    The effects of temperature and loading rate on delamination growth were studied. The delamination fracture toughness of IM7/K3B was measured at 149 C, 177 C, and 204 C. At each temperature the tests were performed with a variety of loading rates so that the delamination initiated over the range of time from 0.5 sec to 24 hrs. The double cantilever beam (DCB) test was used to measure fracture toughness. The results showed that the delamination resistance is a complicated function of both time and temperature with the effect of temperature either increasing or decreasing the fracture toughness depending on the time scale. The results also showed that the fracture toughness changed by as much as a factor of three as the time scale changed over the five orders of magnitude tested.

  20. Two-phase working fluids for the temperature range of 50 to 350 deg, phase 2

    NASA Technical Reports Server (NTRS)

    Saaski, E. W.; Hartl, J. H.

    1980-01-01

    Several two phase heat transfer fluids were tested in aluminum and carbon steel reflux capsules for over 25,000 hours at temperatures up to 300 C. Several fluids showed very good stability and would be useful for long duration heat transfer applications over the range 100 to 350 C. Instrumentation for the measurement of surface tension and viscosity were constructed for use with heat transfer fluids over the temperature range 0 to 300 C and with pressures from 0 to 10 atmospheres. The surface tension measuring device constructed requires less than a 1.0 cc sample and displays an accuracy of about 5 percent in preliminary tests, while the viscometer constructed for this program requires a 0.05 cc sample and shows an accuracy of about 5 percent in initial tests.

  1. Dried Blood Spot Test for HIV Exposed Infants and Children and Their Anti-Retro Viral Treatment Status in Selected Hospitals in Ethiopia.

    PubMed

    Wondafrash, Beyene; Hiko, Desta

    2016-01-01

    Infants and children living with HIV receive antiretroviral treatment often late, are exposed to opportunistic infection and quickly develop AIDS. Few hospitals are providing ART service after Dried Blood Spot (DBS)test.The objective of this study is to assess the status of infants and children linked to ART. Descriptive cross-sectional study was conducted in hospitals. Data of 138 infants and children exposed to HIV were collected from registration books and data bases from 2009 to 2011. Data were analyzed using SPSS version 16. Chi-squared test and p-value were computed. In-depth interviews were conducted with key informants. Ninety-eight (71%) infants and children exposed to HIV were diagnosed for HIV infection of which 68(69.4%) initiated ART. Twenty four (35.3%) initiated ART one month after HIV screening results. Thirty-three (50.0%) and 23(35.3%) infants and children dropped from and adhered to ART respectively. Eleven (16.2%) of them who initiated ART died within the study period. HIV infection status (p-value=0.003), dropping from ART (p-value=0.002) and death after ART initiation (p-value=0.010) showed significance with mothers' PMTCT service status. Seven in ten HIV-exposed infants and children were diagnosed with HIV, and almost all of them initiated ART. The overall turnaround time was 10 days. Based up on mothers' PMTCT service status, there was a significant difference among HIV-exposed infants and children in acquiring HIV infection from mothers during pregnancy (p-value=0.003) and dropping from ART (p-value=0.010). There were challenges in sample collection and transportation. Early HIV screening during pregnancy and PMTCT service should be strengthened.

  2. Is Memory Search Governed by Universal Principles or Idiosyncratic Strategies?

    PubMed Central

    Healey, M. Karl; Kahana, Michael J.

    2013-01-01

    Laboratory paradigms have provided an empirical foundation for much of psychological science. Some have argued, however, that such paradigms are highly susceptible to idiosyncratic strategies and that rather than reflecting fundamental cognitive principles, many findings are artifacts of averaging across participants who employ different strategies. We develop a set of techniques to rigorously test the extent to which average data are distorted by such strategy differences and apply these techniques to free recall data from the Penn Electrophysiology of Encoding and Retrieval Study (PEERS). Recall initiation showed evidence of subgroups: the majority of participants initiate recall from the last item in the list, but one subgroup show elevated initiation probabilities for items 2–4 back from the end of the list and another showed elevated probabilities for the beginning of the list. By contrast, serial position curves and temporal and semantic clustering functions were remarkably consistent, with almost every participant exhibiting a recognizable version of the average function, suggesting that these functions reflect fundamental principles of the memory system. The approach taken here can serve as a model for evaluating the extent to which other laboratory paradigms are influenced by individual differences in strategy use. PMID:23957279

  3. Design and Operation of a Calorimeter for Advanced Multilayer Insulation Testing

    NASA Technical Reports Server (NTRS)

    Chato, David J.; Johnson, Wesley L.; Van Dresar, Neil

    2016-01-01

    A calorimeter has been constructed to accurately measure insulation performance with a nominal 90K outer boundary and a 20K inner boundary. Unique features of this design include use of mechanical cryocoolers instead of cryogens and measurement of the heat load with a calibrated heat conduction rod. The calorimeter is operational and has completed its first test series. The initial test series was designed to look for differences in performance between a single layer of aluminum foil and a sheet of double aluminized Mylar (DAM). Although it has been speculated that the aluminum foil would perform better, since the aluminum coating on the Mylar might not be thick enough to stop the transmission of long wave length infrared radiation, our testing showed a higher heat load for the aluminum foil than the DAM. The aluminum foil showed a heat load of 132 mW at an 87 K outer temperature and 152 mW at a 107K outer temperature, whereas the DAM showed a heat load of 66 mW at an 88 K outer temperature and 81 mW at 108 K.

  4. Design and Operation of a Calorimeter for Advanced Multilayer Insulation Testing

    NASA Technical Reports Server (NTRS)

    Chato, David; Johnson, Wesley; Dresar, Neil Van

    2016-01-01

    A calorimeter has been constructed to accurately measure insulation performance with a nominal 90K cold outer boundary and a 20K inner boundary. Unique features of this design include use of mechanical cryocoolers instead cryogens and measurement of the heat load with a calibrated rod to serve as a conduction path. The calorimeter is operational and has completed its first test series. The initial test series was designed to look for differences in performance between a single layer of aluminum foil and a sheet of double aluminized mylar (DAM). Although it has been speculated that the aluminum foil would perform better, since the mylar coating might not thick enough to stop the transmission of long wave length infrared radiation, our testing showed a higher heat load for the aluminum foil than the DAM. The aluminum foil showed a heat load of 132 mW at an 87 K outer temperature and 152 mW at a 107K outer temperature. Whereas the DAM showed a heat load of 66 mW at an 88 K outer temperature and 81 mW at 108 K.

  5. 10 CFR 26.97 - Conducting an initial test for alcohol using a specimen of oral fluids.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Conducting an initial test for alcohol using a specimen of oral fluids. 26.97 Section 26.97 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.97 Conducting an initial test for alcohol using a specimen of oral...

  6. 10 CFR 26.97 - Conducting an initial test for alcohol using a specimen of oral fluids.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Conducting an initial test for alcohol using a specimen of oral fluids. 26.97 Section 26.97 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.97 Conducting an initial test for alcohol using a specimen of oral...

  7. 10 CFR 26.97 - Conducting an initial test for alcohol using a specimen of oral fluids.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Conducting an initial test for alcohol using a specimen of oral fluids. 26.97 Section 26.97 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.97 Conducting an initial test for alcohol using a specimen of oral...

  8. 10 CFR 26.97 - Conducting an initial test for alcohol using a specimen of oral fluids.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Conducting an initial test for alcohol using a specimen of oral fluids. 26.97 Section 26.97 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.97 Conducting an initial test for alcohol using a specimen of oral...

  9. 10 CFR 26.97 - Conducting an initial test for alcohol using a specimen of oral fluids.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Conducting an initial test for alcohol using a specimen of oral fluids. 26.97 Section 26.97 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.97 Conducting an initial test for alcohol using a specimen of oral...

  10. Effects of pH, initial Pb2+ concentration, and polyculture on lead remediation by three duckweed species.

    PubMed

    Tang, Jie; Chen, Chunxia; Chen, Lei; Daroch, Maurycy; Cui, Yan

    2017-10-01

    Various geographical duckweed isolates have been developed for phytoremediation of lead. The Pb 2+ removal efficiency of Lemna aequinoctialis, Landoltia punctata, and Spirodela polyrhiza was investigated in monoculture and polyculture at different levels of pH and initial Pb 2+ concentrations. L. aequinoctialis was not sensitive to the tested pH but significantly affected by initial Pb 2+ concentration, whereas synergistic effect of pH and initial Pb 2+ concentration on removal efficiency of L. punctata and S. polyrhiza was found. Although the majority of polycultures showed median removal efficiency as compared to respective monocultures, some of the polycultures achieved higher Pb 2+ removal efficiencies and can promote population to remove Pb 2+ . Besides, the three duckweed strains could be potential candidates for Pb 2+ remediation as compared to previous reports. Conclusively, this study provides useful references for future large-scale duckweed phytoremediation.

  11. Left prefrontal cortex activation during sentence comprehension covaries with grammatical knowledge in children.

    PubMed

    Knoll, L J; Obleser, J; Schipke, C S; Friederici, A D; Brauer, J

    2012-08-01

    Children's language skills develop rapidly with increasing age, and several studies indicate that they use language- and age-specific strategies to understand complex sentences. In the present experiment, functional magnetic resonance imaging (fMRI) and behavioral measures were used to investigate the acquisition of case-marking cues for sentence interpretation in the developing brain of German preschool children with a mean age of 6 years. Short sentences were presented auditorily, consisting of a transitive verb and two case-marked arguments with canonical subject-initial or non canonical object-initial word order. Overall group results revealed mainly left hemispheric activation in the perisylvian cortex with increased activation in the inferior parietal cortex (IPC), and the anterior cingulate cortex (ACC) for object-initial compared to subject-initial sentences. However, single-subject analysis suggested two distinct activation patterns within the group which allowed a classification into two subgroups. One subgroup showed the predicted activation increase in the left inferior frontal gyrus (IFG) for the more difficult object-initial compared to subject-initial sentences, while the other group showed the reverse effect. This activation in the left IFG can be taken to reflect the degree to which adult-like sentence processing strategies, necessary to integrate case-marking information, are applied. Additional behavioral data on language development tests show that these two subgroups differ in their grammatical knowledge. Together with these behavioral findings, the results indicate that the use of a particular processing strategy is not dependent on age as such, but rather on the child's individual grammatical knowledge and the ability to use specific language cues for successful sentence comprehension. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Combination of graph heuristics in producing initial solution of curriculum based course timetabling problem

    NASA Astrophysics Data System (ADS)

    Wahid, Juliana; Hussin, Naimah Mohd

    2016-08-01

    The construction of population of initial solution is a crucial task in population-based metaheuristic approach for solving curriculum-based university course timetabling problem because it can affect the convergence speed and also the quality of the final solution. This paper presents an exploration on combination of graph heuristics in construction approach in curriculum based course timetabling problem to produce a population of initial solutions. The graph heuristics were set as single and combination of two heuristics. In addition, several ways of assigning courses into room and timeslot are implemented. All settings of heuristics are then tested on the same curriculum based course timetabling problem instances and are compared with each other in terms of number of population produced. The result shows that combination of saturation degree followed by largest degree heuristic produce the highest number of population of initial solutions. The results from this study can be used in the improvement phase of algorithm that uses population of initial solutions.

  13. Influence of initial pH on thermophilic anaerobic co-digestion of swine manure and maize stalk.

    PubMed

    Zhang, Tong; Mao, Chunlan; Zhai, Ningning; Wang, Xiaojiao; Yang, Gaihe

    2015-01-01

    The contradictions between the increasing energy demand and decreasing fossil fuels are making the use of renewable energy the key to the sustainable development of energy in the future. Biogas, a renewable clean energy, can be obtained by the anaerobic fermentation of manure waste and agricultural straw. This study examined the initial pH value had obvious effect on methane production and the process in the thermophilic anaerobic co-digestion. Five different initial pH levels with three different manure ratios were tested. All digesters in different initial pH showed a diverse methane production after 35 days. The VFA/alkalinity ratio of the optimum reaction condition for methanogens activity was in the range of 0.1-0.3 and the optimal condition that at the 70% dung ratio and initial pH 6.81, was expected to achieve maximum total biogas production (146.32 mL/g VS). Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Employability and personal initiative as antecedents of job satisfaction.

    PubMed

    Gamboa, Juan Pablo; Gracia, Francisco; Ripoll, Pilar; Peiró, José María

    2009-11-01

    In a changing and flexible labour market it is important to clarify the role of environmental and personal variables that contribute to obtaining adequate levels of job satisfaction. The aim of the present study is to analyze the direct effects of employability and personal initiative on intrinsic, extrinsic and social job satisfaction, clarifying their cumulative and interactive effects. The study has been carried out in a sample of 1319 young Spanish workers. Hypotheses were tested by means of the moderated hierarchical regression analysis. Results show that employability and personal initiative predict in a cumulative way the intrinsic, extrinsic and social job satisfaction. Moreover, the interaction between employability and personal initiative increases the prediction of these two variables on intrinsic and extrinsic job satisfaction. Results also indicate that higher values of employability when initiative is also high are associated to higher levels of intrinsic and extrinsic satisfaction. These results have implications for theory and practice in a context of new employment relations.

  15. Stratigraphic response and mammalian dispersal during initial India-Asia collision: Evidence from the Ghazij Formation, Balochistan, Pakistan

    NASA Astrophysics Data System (ADS)

    Clyde, William C.; Khan, Intizar H.; Gingerich, Philip D.

    2003-12-01

    Initial continental collision between India and Asia is thought to have caused significant changes to global climate and biota, yet its timing and biogeographic consequences are uncertain. Structural and geophysical evidence indicates initial collision during the early Paleogene, but sedimentary evidence of this has been controversial owing to the intense deformation and metamorphism along the suture zone. Modern orders of mammals that appeared abruptly on northern continents coincident with the global warming event marking the Paleocene-Eocene boundary are hypothesized to have originated on the Indian subcontinent, but no relevant paleontological information has been available to test this idea. Here we present new paleomagnetic, sedimentologic, and paleontologic evidence to show that the lower Eocene Ghazij Formation of western Pakistan records continental sedimentation and mammalian dispersal associated with initial India-Asia collision. Our results are consistent with the initial collision occurring near the Paleocene-Eocene boundary, but modern orders of mammals appeared later in Indo-Pakistan and thus did not likely originate on the Indian subcontinent.

  16. Pilot study of pharmacist-assisted delivery of pharmacogenetic testing in a primary care setting.

    PubMed

    Haga, Susanne B; LaPointe, Nancy M Allen; Cho, Alex; Reed, Shelby D; Mills, Rachel; Moaddeb, Jivan; Ginsburg, Geoffrey S

    2014-09-01

    To describe the rationale and design of a pilot program to implement and evaluate pharmacogenetic (PGx) testing in a primary care setting. Several factors have impeded the uptake of PGx testing, including lack of provider knowledge and challenges with operationalizing PGx testing in a clinical practice setting. We plan to compare two strategies for the implementation of PGx testing: a pharmacist-initiated testing arm compared with a physician-initiated PGx testing arm. Providers in both groups will be required to attend an introduction to PGx seminar. Anticipated results: We anticipate that providers in the pharmacist-initiated group will be more likely to order PGx testing than providers in the physician-initiated group. Overall, we aim to generate data that will inform an effective delivery model for PGx testing and to facilitate a seamless integration of PGx testing in primary care practices.

  17. 7075-T6 and 2024-T351 Aluminum Alloy Fatigue Crack Growth Rate Data

    NASA Technical Reports Server (NTRS)

    Forth, Scott C.; Wright, Christopher W.; Johnston, William M., Jr.

    2005-01-01

    Experimental test procedures for the development of fatigue crack growth rate data has been standardized by the American Society for Testing and Materials. Over the past 30 years several gradual changes have been made to the standard without rigorous assessment of the affect these changes have on the precision or variability of the data generated. Therefore, the ASTM committee on fatigue crack growth has initiated an international round robin test program to assess the precision and variability of test results generated using the standard E647-00. Crack growth rate data presented in this report, in support of the ASTM roundrobin, shows excellent precision and repeatability.

  18. Pragmatic and executive functions in traumatic brain injury and right brain damage: An exploratory comparative study

    PubMed Central

    Zimmermann, Nicolle; Gindri, Gigiane; de Oliveira, Camila Rosa; Fonseca, Rochele Paz

    2011-01-01

    Objective To describe the frequency of pragmatic and executive deficits in right brain damaged (RBD) and in traumatic brain injury (TBI) patients, and to verify possible dissociations between pragmatic and executive functions in these two groups. Methods The sample comprised 7 cases of TBI and 7 cases of RBD. All participants were assessed by means of tasks from the Montreal Communication Evaluation Battery and executive functions tests including the Trail Making Test, Hayling Test, Wisconsin Card Sorting Test, semantic and phonemic verbal fluency tasks, and working memory tasks from the Brazilian Brief Neuropsychological Assessment Battery NEUPSILIN. Z-score was calculated and a descriptive analysis of frequency of deficits (Z< -1.5) was carried out. Results RBD patients presented with deficits predominantly on conversational and narrative discursive tasks, while TBI patients showed a wider spread pattern of pragmatic deficits. Regarding EF, RBD deficits included predominantly working memory and verbal initiation impairment. On the other hand, TBI individuals again exhibited a general profile of executive dysfunction, affecting mainly working memory, initiation, inhibition, planning and switching. Pragmatic and executive deficits were generally associated upon comparisons of RBD patients and TBI cases, except for two simple dissociations: two post-TBI cases showed executive deficits in the absence of pragmatic deficits. Discussion Pragmatic and executive deficits can be very frequent following TBI or vascular RBD. There seems to be an association between these abilities, indicating that although they can co-occur, a cause-consequence relationship cannot be the only hypothesis. PMID:29213762

  19. [Undulant fever and autoimmune hemolytic anemia in a 20-year-old exchange student from Jordan - the human brucellosis as an important differential diagnosis in migrants].

    PubMed

    Trawinski, Henning; Gräber, Sandra; Leifels, Michael; Schubert, Stefan; Lübbert, Christoph

    2015-12-01

    A 20-year-old Jordanian exchange student presents with recurrent fever, night sweats, cough, and swelling and redness around the ankle. Physical examination further reveals bilateral ankle arthritis and painful cervical lymphadenopathy. Laboratory tests show signs of autoimmune hemolytic anemia, elevated liver function tests, and moderate laboratory signs of inflammation. All blood cultures reveal growth of gram-negative coccoid rods which are initially identified by mass spectrometry as Moraxella lacunata and Ochrobactrum anthropi. However, antimicrobial therapy with imipenem / cilastatin does not improve the patient's clinical condition. Based on the travel history including consumption of yogurt from unpasteurized sheep's milk, we perform serological tests with a strongly positive result for Brucella species, and additional work-up of blood culture isolates confirm the definitive diagnosis of brucellosis (Malta fever, infection by Brucella melitensis). After initiation of antimicrobial therapy with doxycycline and rifampin the patient shows complete resolution of fever. Arthritis, autoimmune hemolytic anemia and accompanying hepatitis improve in the course. Thus, since brucellosis is endemic to countries like Jordan, it should be considered as a possible agent of fever of unknown origin especially in migrants unresponsive to empiric therapy and appropriate diagnostic tests including meticulous validation of blood cultures should be performed. Standard therapy is a combination of doxycycline with rifampin for at least 6 weeks. © Georg Thieme Verlag KG Stuttgart · New York.

  20. MEASURING SPORT-SPECIFIC PHYSICAL ABILITIES IN MALE GYMNASTS: THE MEN'S GYMNASTICS FUNCTIONAL MEASUREMENT TOOL

    PubMed Central

    Kenyon, Lisa K.; Elliott, James M; Cheng, M. Samuel

    2016-01-01

    Purpose/Background Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. Methods A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts’ USA-Gymnastics competitive level to calculate the coefficient of determination (r2). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. Results The relationship between total MGFMT scores and subjects’ current USA-Gymnastics competitive level was found to be good (r2 = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). Conclusions The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level of Evidence Level 3 PMID:27999723

  1. Distribution of Inclusion-Initiated Fatigue Cracking in Powder Metallurgy Udimet 720 Characterized

    NASA Technical Reports Server (NTRS)

    Bonacuse, Peter J.; Kantzos, Pete T.; Barrie, Robert; Telesman, Jack; Ghosn, Louis J.; Gabb, Timothy P.

    2004-01-01

    In the absence of extrinsic surface damage, the fatigue life of metals is often dictated by the distribution of intrinsic defects. In powder metallurgy (PM) alloys, relatively large defects occur rarely enough that a typical characterization with a limited number of small volume fatigue test specimens will not adequately sample inclusion-initiated damage. Counterintuitively, inclusion-initiated failure has a greater impact on the distribution in PM alloy fatigue lives because they tend to have fewer defects than their cast and wrought counterparts. Although the relative paucity of defects in PM alloys leads to higher mean fatigue lives, the distribution in observed lives tends to be broader. In order to study this important failure initiation mechanism without expending an inordinate number of specimens, a study was undertaken at the NASA Glenn Research Center where known populations of artificial inclusions (seeds) were introduced to production powder. Fatigue specimens were machined from forgings produced from the seeded powder. Considerable effort has been expended in characterizing the crack growth rate from inclusion-initiated cracks in seeded PM alloys. A rotating and translating positioning system, with associated software, was devised to map the surface inclusions in low-cycle fatigue (LCF) test bars and to monitor the crack growth from these inclusions. The preceding graph illustrates the measured extension in fatigue cracks from inclusions on a seeded LCF test bar subjected to cyclic loading at a strain range of 0.8 percent and a strain ratio (max/min) of zero. Notice that the observed inclusions fall into three categories: some do not propagate at all (arrest), some propagate with a decreasing crack growth rate, and a few propagate at increasing rates that can be modeled by fracture mechanics. The following graph shows the measured inclusion-initiated crack growth rates from 10 interrupted LCF tests plotted against stress intensities calculated for semi-elliptical cracks with the observed surface lengths. The expected scatter in the crack growth rates for stress intensity ranges near threshold is observed. These data will be used to help determine the distribution in growth rates of cracks emanating from inclusions as well as the proportion of cracks that arrest under various loading conditions.

  2. Results of the Boeing/DOE DECC Phase 1 stirling engine project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    STONE,KENNETH W.; CLARK,TERRY; NELVING,HANS

    2000-03-02

    Phase I of Boeing Company/DOE Dish Engine Critical Component (DECC) Project started in April of 1998 and was completed in 1999. The Phase I objectives, schedule, and test results are presented in this paper. These data shows the power, energy, and mirror performance are comparable to that when the hardware was first manufactured 15 years ago. During the Phase I and initial Phase II test period the on-sun system accumulated over 3,800 hours of solar-powered operating time, accumulated over 4,500 hours of concentrator solar tracking time, and generated over 50,000 kWh of grid-compatible electrical energy. The data also shows thatmore » the system was available 95 {percent} of the time when the sun's insolation level was above approximately 300 w/m{sup 2}, and achieved a daily energy efficiency between 20{percent} and 26{percent}. A second concentrator was refurbished during Phase I and accumulated over 2,200 hours of solar track time. A second Stirling engine operated 24 hours a day in a test cell in Sweden and accumulated over 6,000 test hours. Discussion of daily operation shows no major problems encountered during the testing that would prevent commercialization of the technology. Further analysis of the test data shows that system servicing with hydrogen, coolant and lubricating oil should not be a major O and M cost.« less

  3. The Incongruency Advantage for Environmental Sounds Presented in Natural Auditory Scenes

    ERIC Educational Resources Information Center

    Gygi, Brian; Shafiro, Valeriy

    2011-01-01

    The effect of context on the identification of common environmental sounds (e.g., dogs barking or cars honking) was tested by embedding them in familiar auditory background scenes (street ambience, restaurants). Initial results with subjects trained on both the scenes and the sounds to be identified showed a significant advantage of about five…

  4. Effects of backing board materials on wood combustion performance

    Treesearch

    Mathew J. Hagge; Kenneth M. Bryden; Mark A. Dietenberger

    2004-01-01

    Cone calorimeter tests show that backing board materials do not affect the ignition time, initial heat release rate, or the total heat released of combustion for redwood slabs. However, it has been observed that backing board materials alter combustion performance by altering the secondary heat release peak observed when the pyrolysis reaction front nears the unheated...

  5. How 7-Month-Olds Interpret Ambiguous Motion Events: Category-Based Reasoning in Infancy

    ERIC Educational Resources Information Center

    Pauen, Sabina; Trauble, Birgit

    2009-01-01

    This paper investigates the role of static and dynamic attributes for the animate-inanimate distinction in category-based reasoning of 7-month-olds. Three experiments tested infants' responses to movement events involving an unfamiliar animal and a ball. When either the animal or the ball showed self-initiated irregular movements (Experiment 1),…

  6. Grammar Predicts Procedural Learning and Consolidation Deficits in Children with Specific Language Impairment

    PubMed Central

    Hedenius, Martina; Persson, Jonas; Tremblay, Antoine; Adi-Japha, Esther; Veríssimo, João; Dye, Cristina D.; Alm, Per; Jennische, Margareta; Tomblin, J. Bruce; Ullman, Michael T.

    2011-01-01

    The Procedural Deficit Hypothesis (PDH) posits that Specific Language Impairment (SLI) can be largely explained by abnormalities of brain structures that subserve procedural memory. The PDH predicts impairments of procedural memory itself, and that such impairments underlie the grammatical deficits observed in the disorder. Previous studies have indeed reported procedural learning impairments in SLI, and have found that these are associated with grammatical difficulties. The present study extends this research by examining the consolidation and longer-term procedural sequence learning in children with SLI. The Alternating Serial Reaction Time (ASRT) task was given to children with SLI and typically-developing (TD) children in an initial learning session and an average of three days later to test for consolidation and longer-term learning. Although both groups showed evidence of initial sequence learning, only the TD children showed clear signs of consolidation, even though the two groups did not differ in longer-term learning. When the children were re-categorized on the basis of grammar deficits rather than broader language deficits, a clearer pattern emerged. Whereas both the grammar impaired and normal grammar groups showed evidence of initial sequence learning, only those with normal grammar showed consolidation and longer-term learning. Indeed, the grammar-impaired group appeared to lose any sequence knowledge gained during the initial testing session. These findings held even when controlling for vocabulary or a broad non-grammatical language measure, neither of which were associated with procedural memory. When grammar was examined as a continuous variable over all children, the same relationships between procedural memory and grammar, but not vocabulary or the broader language measure, were observed. Overall, the findings support and further specify the PDH. They suggest that consolidation and longer-term procedural learning are impaired in SLI, but that these impairments are specifically tied to the grammatical deficits in the disorder. The possibility that consolidation and longer-term learning are problematic in the disorder suggests a locus of potential study for therapeutic approaches. In sum, this study clarifies our understanding of the underlying deficits in SLI, and suggests avenues for further research. PMID:21840165

  7. Fit Assessment of N95 Filtering-Facepiece Respirators in the U.S. Centers for Disease Control and Prevention Strategic National Stockpile.

    PubMed

    Bergman, Michael; Zhuang, Ziqing; Brochu, Elizabeth; Palmiero, Andrew

    National Institute for Occupational Safety and Health (NIOSH)-approved N95 filtering-facepiece respirators (FFR) are currently stockpiled by the U.S. Centers for Disease Control and Prevention (CDC) for emergency deployment to healthcare facilities in the event of a widespread emergency such as an influenza pandemic. This study assessed the fit of N95 FFRs purchased for the CDC Strategic National Stockpile. The study addresses the question of whether the fit achieved by specific respirator sizes relates to facial size categories as defined by two NIOSH fit test panels. Fit test data were analyzed from 229 test subjects who performed a nine-donning fit test on seven N95 FFR models using a quantitative fit test protocol. An initial respirator model selection process was used to determine if the subject could achieve an adequate fit on a particular model; subjects then tested the adequately fitting model for the nine-donning fit test. Only data for models which provided an adequate initial fit (through the model selection process) for a subject were analyzed for this study. For the nine-donning fit test, six of the seven respirator models accommodated the fit of subjects (as indicated by geometric mean fit factor > 100) for not only the intended NIOSH bivariate and PCA panel sizes corresponding to the respirator size, but also for other panel sizes which were tested for each model. The model which showed poor performance may not be accurately represented because only two subjects passed the initial selection criteria to use this model. Findings are supportive of the current selection of facial dimensions for the new NIOSH panels. The various FFR models selected for the CDC Strategic National Stockpile provide a range of sizing options to fit a variety of facial sizes.

  8. Fit Assessment of N95 Filtering-Facepiece Respirators in the U.S. Centers for Disease Control and Prevention Strategic National Stockpile

    PubMed Central

    Bergman, Michael; Zhuang, Ziqing; Brochu, Elizabeth; Palmiero, Andrew

    2016-01-01

    National Institute for Occupational Safety and Health (NIOSH)-approved N95 filtering-facepiece respirators (FFR) are currently stockpiled by the U.S. Centers for Disease Control and Prevention (CDC) for emergency deployment to healthcare facilities in the event of a widespread emergency such as an influenza pandemic. This study assessed the fit of N95 FFRs purchased for the CDC Strategic National Stockpile. The study addresses the question of whether the fit achieved by specific respirator sizes relates to facial size categories as defined by two NIOSH fit test panels. Fit test data were analyzed from 229 test subjects who performed a nine-donning fit test on seven N95 FFR models using a quantitative fit test protocol. An initial respirator model selection process was used to determine if the subject could achieve an adequate fit on a particular model; subjects then tested the adequately fitting model for the nine-donning fit test. Only data for models which provided an adequate initial fit (through the model selection process) for a subject were analyzed for this study. For the nine-donning fit test, six of the seven respirator models accommodated the fit of subjects (as indicated by geometric mean fit factor > 100) for not only the intended NIOSH bivariate and PCA panel sizes corresponding to the respirator size, but also for other panel sizes which were tested for each model. The model which showed poor performance may not be accurately represented because only two subjects passed the initial selection criteria to use this model. Findings are supportive of the current selection of facial dimensions for the new NIOSH panels. The various FFR models selected for the CDC Strategic National Stockpile provide a range of sizing options to fit a variety of facial sizes. PMID:26877587

  9. The effect of surface treatment and clinical use on friction in NiTi orthodontic wires.

    PubMed

    Wichelhaus, Andrea; Geserick, Marc; Hibst, Raimund; Sander, Franz G

    2005-10-01

    Since the low friction of NiTi wires allows a rapid and efficient orthodontic tooth movement, the aim of this research was to investigate the friction and surface roughness of different commercially available superelastic NiTi wires before and after clinical use. The surface of all of the wires had been pre-treated by the manufacturer. Forty superelastic wires (Titanol Low Force, Titanol Low Force River Finish Gold, Neo Sentalloy, Neo Sentalloy Ionguard) of diameter 0.016 x 0.022 in. were tested. The friction for each type of NiTi archwire ligated into a commercial stainless steel bracket was determined with a universal testing machine. Having ligated the wire into the bracket, it could then be moved forward and backwards along a fixed archwire whilst a torquing moment was applied. The surface roughness was investigated using a profilometric measuring device on defined areas of the wire. Statistical data analysis was conducted by means of the Wilcoxon test. The results showed that initially, the surface treated wires demonstrated significantly (p < 0.01) less friction than the non-treated wires. The surface roughness showed no significant difference between the treated and the non-treated surfaces of the wires. All 40 wires however showed a significant increase in friction and surface roughness during clinical use. Whilst the Titanol Low Force River Finish Gold (Forestadent, Pforzheim, Germany) wires showed the least friction of all the samples and consequently should be more conservative on anchorage, the increase in friction of all the surface treated wires during orthodontic treatment almost cancels out this initial effect on friction. It is therefore recommended that surface treated NiTi orthodontic archwires should only be used once.

  10. Chronic Granulomatous Disease Presenting as Aspergillus Fumigatus Pneumonia in a Previously Healthy Young Woman.

    PubMed

    Williams, David; Kadaria, Dipen; Sodhi, Amik; Fox, Roy; Williams, Glenn; Threlkeld, Stephen

    2017-04-05

    BACKGROUND Chronic Granulomatous Disease (CGD) is a rare immunodeficiency disease caused by a genetic defect in the NADPH (nicotinamide adenine dinucleotide phosphate) oxidase enzyme, resulting in increased susceptibility to bacterial and fungal infections. The inheritance can be X-linked or autosomal recessive. Patients usually present with repeated infections early in life. We present an unusual case of a 23-year-old patient diagnosed with CGD. CASE REPORT A 23-year-old white woman with no previous history of recurrent infections presented with complaints of fever, shortness of breath, and diffuse myalgia. She had been treated twice for similar complaints recently, but without resolution. She was febrile, tachypneic, tachycardic, and hypoxic at presentation. Physical examination revealed diffuse inspiratory rales. Laboratory results showed leukocytosis. Her initial chest X-ray and CT chest showed reticular nodular interstitial lung disease pattern. Despite being on broad-spectrum antibiotics for 5 days, she continued to require supplemental oxygen and continued to be tachypneic, with minimal activity. Initial diagnostic tests, including bronchoscopy with biopsy and lavage, did not reveal a diagnosis. She then underwent a video-assisted thoracoscopic surgery (VATS) lung biopsy. The biopsy slides showed suppurative granulomatous inflammation affecting greater than 50% of the parenchymal lung surface. Fungal hyphae consistent with Aspergillus were present in those granulomas. A diagnosis of CGD was made and she was started on Voriconazole. She improved with treatment. Her neutrophil burst test showed negative burst on stimulation, indicating phagocytic dysfunction consistent with CGD. Autosomal recessive CGD was confirmed by genetic testing. CONCLUSIONS CGD can present in adulthood without any previous symptoms and signs. Clinicians should consider this disease in patients presenting with recurrent or non-resolving infections. Timely treatment and prophylaxis has been shown to reduce serious infections as well as mortality in these patients.

  11. Influence of Surfactants and Fluoride against Enamel Erosion.

    PubMed

    Zanatta, Rayssa Ferreira; Ávila, Daniele Mara da Silva; Miyamoto, Karen Mayumi; Torres, Carlos Rocha Gomes; Borges, Alessandra Bühler

    2018-06-06

    This study investigated the effect of surfactants associated with sodium fluoride (NaF) on enamel erosion prevention, using an erosion-remineralization in vitro model. Sodium lauryl sulfate (SLS), polysorbate 20 (P20), and cocoamidopropyl betaine (CAPB) were tested, at concentrations of 1.0 and 1.5%, and associated or not with NaF (275 ppm). The control groups were distilled water and the NaF solution. Bovine enamel samples (n = 12) were prepared and submitted to a 5-day cycling model: acid challenge (0.3% citric acid, pH 2.6, 4×/day), human saliva (2 h, 4×/day), and the treatment solutions (2 min, 2×/day). The protective potential of the agents against initial erosion was assessed by microhardness and the surface loss by profilometry. Enamel surface wettability was determined by goniometry, protein adsorption was measured by spectroscopy (FTIR), and the KOH-soluble fluoride was quantified. Goniometry showed that SLS and CAPB increased enamel wettability. No differences were found among the surfactants regarding protein adsorption. Microhardness showed that SLS reduced NaF protection. P20 (1 and 1.5%) and CAPB 1.5% presented a protective effect, but lower than the NaF solution. Profilometry showed that CAPB protected enamel, but no agent associated with NaF promoted a higher protection than the NaF solution alone. KOH-soluble fluoride analysis showed that all surfactants reduced the fluoride adsorption on the enamel surface. Therefore, the surfactants tested (except for P20) changed the enamel surface energy. The SLS decreased the protective potential of NaF on initial erosion, but no tested agent interfered with the protective effect of NaF on enamel erosive wear. © 2018 S. Karger AG, Basel.

  12. 40 CFR 63.7940 - By what date must I conduct performance tests or other initial compliance demonstrations?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... compliance is not demonstrated using a performance test or design evaluation, you must demonstrate initial... performance tests or other initial compliance demonstrations? 63.7940 Section 63.7940 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS...

  13. 14 CFR 135.295 - Initial and recurrent flight attendant crewmember testing requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... PERSONS ON BOARD SUCH AIRCRAFT Crewmember Testing Requirements § 135.295 Initial and recurrent flight attendant crewmember testing requirements. No certificate holder may use a flight attendant crewmember, nor... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Initial and recurrent flight attendant...

  14. 14 CFR 135.295 - Initial and recurrent flight attendant crewmember testing requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... PERSONS ON BOARD SUCH AIRCRAFT Crewmember Testing Requirements § 135.295 Initial and recurrent flight attendant crewmember testing requirements. No certificate holder may use a flight attendant crewmember, nor... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Initial and recurrent flight attendant...

  15. 14 CFR 135.295 - Initial and recurrent flight attendant crewmember testing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... PERSONS ON BOARD SUCH AIRCRAFT Crewmember Testing Requirements § 135.295 Initial and recurrent flight attendant crewmember testing requirements. No certificate holder may use a flight attendant crewmember, nor... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Initial and recurrent flight attendant...

  16. 14 CFR 135.295 - Initial and recurrent flight attendant crewmember testing requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... PERSONS ON BOARD SUCH AIRCRAFT Crewmember Testing Requirements § 135.295 Initial and recurrent flight attendant crewmember testing requirements. No certificate holder may use a flight attendant crewmember, nor... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Initial and recurrent flight attendant...

  17. 14 CFR 125.289 - Initial and recurrent flight attendant crewmember testing requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AIRCRAFT Flight Crewmember Requirements § 125.289 Initial and recurrent flight attendant crewmember testing... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Initial and recurrent flight attendant crewmember testing requirements. 125.289 Section 125.289 Aeronautics and Space FEDERAL AVIATION...

  18. 14 CFR 125.289 - Initial and recurrent flight attendant crewmember testing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRCRAFT Flight Crewmember Requirements § 125.289 Initial and recurrent flight attendant crewmember testing... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Initial and recurrent flight attendant crewmember testing requirements. 125.289 Section 125.289 Aeronautics and Space FEDERAL AVIATION...

  19. 14 CFR 135.295 - Initial and recurrent flight attendant crewmember testing requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... PERSONS ON BOARD SUCH AIRCRAFT Crewmember Testing Requirements § 135.295 Initial and recurrent flight attendant crewmember testing requirements. No certificate holder may use a flight attendant crewmember, nor... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Initial and recurrent flight attendant...

  20. 14 CFR 125.289 - Initial and recurrent flight attendant crewmember testing requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AIRCRAFT Flight Crewmember Requirements § 125.289 Initial and recurrent flight attendant crewmember testing... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Initial and recurrent flight attendant crewmember testing requirements. 125.289 Section 125.289 Aeronautics and Space FEDERAL AVIATION...

  1. 14 CFR 125.289 - Initial and recurrent flight attendant crewmember testing requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AIRCRAFT Flight Crewmember Requirements § 125.289 Initial and recurrent flight attendant crewmember testing... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Initial and recurrent flight attendant crewmember testing requirements. 125.289 Section 125.289 Aeronautics and Space FEDERAL AVIATION...

  2. 14 CFR 125.289 - Initial and recurrent flight attendant crewmember testing requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AIRCRAFT Flight Crewmember Requirements § 125.289 Initial and recurrent flight attendant crewmember testing... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Initial and recurrent flight attendant crewmember testing requirements. 125.289 Section 125.289 Aeronautics and Space FEDERAL AVIATION...

  3. Corrosion Behavior of Silver-Plated Circuit Boards in a Simulated Marine Environment with Industrial Pollution

    PubMed Central

    Xiao, Kui; Yi, Pan; Yan, Lidan; Bai, Ziheng; Dong, Chaofang; Dong, Pengfei; Gao, Xiong

    2017-01-01

    The electrochemical corrosion behavior of a silver-plated circuit board (PCB-ImAg) in a polluted marine atmosphere environment (Qingdao in China) is studied through a simulated experiment. The morphologies of PCB-ImAg show some micropores on the surface that act as the corrosion-active points in the tests. Cl− mainly induces microporous corrosion, whereas SO2 causes general corrosion. Notably, the silver color changes significantly under SO2 influence. EIS results show that the initial charge transfer resistance in the test containing SO2 and Cl− is 9.847 × 103, while it is 3.701 × 104 in the test containing Cl− only, which demonstrates that corrosion accelerates in a mixed atmosphere. Polarization curves further show that corrosion potential is lower in mixed solutions (between −0.397 V SCE and −0.214 V SCE) than it in the solution containing Cl− only (−0.168 V SCE), indicating that corrosion tendency increases with increased HSO3− concentration. PMID:28773121

  4. Spring 2014 Internship Diffuser Data Analysis

    NASA Technical Reports Server (NTRS)

    Laigaie, Robert T.; Ryan, Harry M.

    2014-01-01

    J-2X engine testing on the A-2 test stand at the NASA John C. Stennis Space Center (SSC) has recently concluded. As part of that test campaign, the engine was operated at lower power levels in support of expanding the use of J-2X to other missions. However, the A-2 diffuser was not designed for engine testing at the proposed low power levels. To evaluate the risk of damage to the diffuser, computer simulations were created of the rocket engine exhaust plume inside the 50ft long, water-cooled, altitude-simulating diffuser. The simulations predicted that low power level testing would cause the plume to oscillate in the lower sections of the diffuser. This can possibly cause excessive vibrations, stress, and heat transfer from the plume to the diffuser walls. To understand and assess the performance of the diffuser during low power level engine testing, nine accelerometers and four strain gages were installed around the outer surface of the diffuser. The added instrumentation also allowed for the verification of the rocket exhaust plume computational model. Prior to engine hot-fire testing, a diffuser water-flow test was conducted to verify the proper operation of the newly installed instrumentation. Subsequently, two J-2X engine hot-fire tests were completed. Hot-Fire Test 1 was 11.5 seconds in duration, and accelerometer and strain data verified that the rocket engine plume oscillated in the lower sections of the diffuser. The accelerometers showed very different results dependent upon location. The diffuser consists of four sections, with Section 1 being closest to the engine nozzle and Section 4 being farthest from the engine nozzle. Section 1 accelerometers showed increased amplitudes at startup and shutdown, but low amplitudes while the diffuser was started. Section 3 accelerometers showed the opposite results with near zero G amplitudes prior to and after diffuser start and peak amplitudes to +/- 100G while the diffuser was started. Hot-Fire Test 1 strain gages showed different data dependent on section. Section 1 strains were small, and were in the range of 50 to 150 microstrain, which would result in stresses from 1.45 to 4.35 ksi. The yield stress of the material, A-285 Grade C Steel, is 29.7 ksi. Section 4 strain gages showed much higher values with strains peaking at 1600 microstrain. This strain corresponds to a stress of 46.41 ksi, which is in excess of the yield stress, but below the ultimate stress of 55 to 75 ksi. The decreased accelerations and strain in Section 1, and the increased accelerations and strain in Sections 3 and 4 verified the computer simulation prediction of increased plume oscillations in the lower sections of the diffuser. Hot-Fire Test 2 ran for a duration of 125 seconds. The engine operated at a slightly higher power level than Hot-Fire Test 1 for the initial 35 seconds of the test. After 35 seconds the power level was lowered to Hot-Fire Test 1 levels. The acceleration and strain data for Hot-Fire Test 2 was similar during the initial part of the test. However, just prior to the engine being lowered to the Hot-Fire Test 1 power level, the strain gage data in Section 4 showed a large decrease to strains near zero microstrain from their peak at 1500 microstrain. Future work includes further strain and acceleration data analysis and evaluation.

  5. Back off! The effect of emotion on backward step initiation.

    PubMed

    Bouman, Daniëlle; Stins, John F

    2018-02-01

    The distance regulation (DR) hypothesis states that actors are inclined to increase their distance from an unpleasant stimulus. The current study investigated the relation between emotion and its effect on the control of backward step initiation, which constitutes an avoidance-like behavior. Participants stepped backward on a force plate in response to neutral, high-arousing pleasant and high-arousing unpleasant visual emotional stimuli. Gait initiation parameters and the results of an exploratory analysis of postural sway were compared across the emotion categories using significance testing and Bayesian statistics. Evidence was found that gait initiation parameters were largely unaffected by emotional conditions. In contrast, the exploratory analysis of postural immobility showed a significant effect: highly arousing stimuli (pleasant and unpleasant) resulted in more postural sway immediately preceding gait initiation compared to neutral stimuli. This suggests that arousal, rather than valence, affects pre-step sway. These results contradict the DR hypothesis, since avoidance gait-initiation in response to unpleasant stimuli was no different compared to pleasant stimuli. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Effect of deacetylation on property of electrospun chitosan/PVA nanofibrous membrane and removal of methyl orange, Fe(III) and Cr(VI) ions.

    PubMed

    Habiba, Umma; Siddique, Tawsif A; Talebian, Sepehr; Lee, Jacky Jia Li; Salleh, Areisman; Ang, Bee Chin; Afifi, Amalina M

    2017-12-01

    In this study, effect of degree of deacetylation on property and adsorption capacity of chitosan/polyvinyl Alcohol electrospun membrane has been investigated. Resulting nanofibers were characterized by FESEM, FTIR, XRD, TGA, tensile testing, weight loss test and adsorption test. FESEM result shows, finer nanofiber was fabricated from 42h hydrolyzed chitosan and PVA blend solution. FTIR and XRD result showed a strong interaction between chitosan and polyvinyl alcohol. Higher tensile strength was observed for the nanofiber having 42h hydrolyzed chitosan. Blend solution of chitosan/PVA having low DD chitosan had higher viscosity. The nanofibrous membrane was stable in distilled water, acidic and basic medium. The isotherm study shows that the adsorption capacity (q m ) of nanofiber containing higher DD chitosan was higher for Cr(VI). In contrary, the membrane containing chitosan with lower DD showed the higher adsorption capacity for Fe(III) and methyl orange. Moreover, the effect of DD on removal percentage of adsorbate was dependent on the initial concentration of the adsorbate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Tensile Properties of Poly (N-vinyl caprolactam) Gels

    NASA Technical Reports Server (NTRS)

    Morgret, Leslie D.; Hinkley, Jeffrey A.

    2004-01-01

    N-vinyl caprolactam was copolymerized with ethylene glycol dimethacrylate using a free-radical initiator in alcohol/water solution. The resulting gels were thermally-responsive in water, undergoing an approximate fivefold reversible volume shrinkage between room temperature and ca. 50 C. Tensile testing showed that the stress-strain behavior was qualitatively different in the collapsed state above the temperature-induced transition. At the higher temperature, gels were stiffer, more ductile, and showed greater time dependence. Implications for the design of gel actuators are briefly discussed.

  8. Department of Defense (DOD) Automated Biometric Identification System (ABIS) Version 1.2: Initial Operational Test and Evaluation Report

    DTIC Science & Technology

    2015-05-01

    Director, Operational Test and Evaluation Department of Defense (DOD) Automated Biometric Identification System (ABIS) Version 1.2 Initial...Operational Test and Evaluation Report May 2015 This report on the Department of Defense (DOD) Automated Biometric Identification System...COVERED - 4. TITLE AND SUBTITLE Department of Defense (DOD) Automated Biometric Identification System (ABIS) Version 1.2 Initial Operational Test

  9. Verb-based versus class-based accounts of actionality effects in children's comprehension of passives.

    PubMed

    Gordon, P; Chafetz, J

    1990-09-01

    Several studies have shown that children perform worse on tests of passive comprehension when the verb is non-actional than when it is actional. Most existing accounts focus on the semantic characteristics of the class of non-action verbs in explaining this difference. An alternative is a "verb-based" account in which passives are initially learned verb by verb, and children hear fewer non-actional passives in their language input. An analysis of the passives heard by Adam, Eve and Sarah (Brown, 1973) found more actional than non-actional passives, consistent with the verb-based account. In a second study, children tested for passive comprehension were re-tested a week later. The verb-based account predicts that children should show a consistent pattern of responses for individual verbs on test and re-test. Such consistency was found, with some inconsistency due to improvement over the re-test. Further analyses showed no effects of affectedness in explaining children's problems with passives. Finally, we discuss whether a mixed model containing both verb-based and class-based mechanisms is required to explain the actionality effects.

  10. The dark side of testing memory: repeated retrieval can enhance eyewitness suggestibility.

    PubMed

    Chan, Jason C K; Lapaglia, Jessica A

    2011-12-01

    Eyewitnesses typically recount their experiences many times before trial. Such repeated retrieval can enhance memory retention of the witnessed event. However, recent studies (e.g., Chan, Thomas, & Bulevich, 2009) have found that initial retrieval can exacerbate eyewitness suggestibility to later misleading information--a finding termed retrieval-enhanced suggestibility (RES). Here we examined the influence of multiple retrieval attempts on eyewitness suggestibility to subsequent misinformation. In four experiments, we systematically varied the number of initial tests taken (between zero and six), the delay between initial testing and misinformation exposure (~30 min or 1 week), and whether initial testing was manipulated between- or within-subjects. University undergraduate students were used as participants. Overall, we found that eyewitness suggestibility increased as the number of initial tests increased, but this RES effect was qualified by the delay and by whether initial testing occurred in a within- or between-subjects manner. Specifically, the within-subjects RES effect was smaller than the between-subjects RES effect, possibly because of the influence of retrieval-induced forgetting/facilitation (Chan, 2009) when initial testing was manipulated within subjects. Moreover, consistent with the testing effect literature (Roediger & Karpicke, 2006), the benefits of repeated testing on later memory were stronger after a 1-week delay than after a 30-min delay, thus reducing the negative impact of RES in long-term situations. These findings suggest that conditions that are likely to occur in criminal investigations can either increase (repeated testing) or reduce (delay) the influence of RES, thus further demonstrating the complex relationship between eyewitness memory and repeated retrieval.

  11. Association between the Frequency of Optic Disk Hemorrhage and Progression of NTG Related with the Initial Location of RNFL Defect.

    PubMed

    Cho, Hyun-Kyung; Lee, Min Gyu; Kee, Changwon

    2018-06-12

    This study aimed to investigate the association of the frequency of optic disk hemorrhage (DH) and progression of normal tension glaucoma (NTG) between each group based on the location of the initial retinal nerve fiber layer (RNFL) defect. In this retrospective, observational cohort study, 142 NTG patients who underwent more than 5 reliable visual field tests with initial superior hemifield (group 2, n = 51), inferior hemifield (group 1, n = 44), or both hemifield (group 3, n = 47) defects were included. The number of DHs was inspected in serial optic disk photographs by 2 different ophthalmologists. Progression rates, which are the slope of mean thresholds from the 52 points, were calculated using a linear mixed effect model. The mean follow-up period was 8.19 ± 3.30 years. DHs related with the initial RNFL defect occurred significantly more frequently in group 2 (35 in inferior hemifield) than in group 1 (6 in superior hemifield) (p = 0.009) or group 3 (6 in inferior hemifield) (p = 0.006). The progression rate in group 2 was significantly faster than in group 1 (p = 0.019) or the superior hemifield of group 3 (p = 0.001). The progression rate of subjects showing recurrent DH was significantly faster than those showing single DH from all groups (-0.5460 vs. -0.2867 dB/year, p = 0.0053). More careful examination and caution are required when NTG patients show recurrent DH in the inferior hemifield related to the initial RNFL defect. © 2018 S. Karger AG, Basel.

  12. Contribution of gustation to the palatability of linoleic acid.

    PubMed

    Saitou, Katsuyoshi; Yoneda, Takeshi; Mizushige, Takafumi; Asano, Hiroki; Okamura, Maya; Matsumura, Shigenobu; Eguchi, Ai; Manabe, Yasuko; Tsuzuki, Satoshi; Inoue, Kazuo; Fushiki, Tohru

    2009-01-08

    We investigated the palatability of a low concentration of linoleic acid (LA) in short-term two-bottle choice tests and licking tests. To examine the contribution of gustation, mice were rendered anosmic with olfactory nerve transection surgery and test solutions were prepared using mineral oil (saturated long-chain hydrocarbon) to minimize textural effects. In the two-bottle choice tests between various pairs of different concentrations of corn oil and LA, both anosmic and the sham-operated mice constantly preferred a higher concentration of corn oil and LA. In the licking tests, the initial licking rate for 1% LA was higher than that for mineral oil in anosmic mice. In accordance with the results of the two-bottle choice test, the initial licking rate for corn oil and LA increased in a concentration-dependent manner in both anosmic and sham-operated mice in the licking test, and reached its peak at 100% corn oil and 1% LA. A preference comparison between 1% LA and 100% corn oil showed that anosmic mice preferred 1% LA over 100% corn oil. These results suggest that mice could recognize dietary fat and fatty acid solutions in the oral cavity without any olfactory or textural cues and the fatty acid recognition on their tongues might provide a pivotal cue to how dietary fat is recognized in the oral cavity.

  13. Gross and fine motor function in fibromyalgia and chronic fatigue syndrome

    PubMed Central

    Rasouli, Omid; Fors, Egil A; Borchgrevink, Petter Chr; Öhberg, Fredrik; Stensdotter, Ann-Katrin

    2017-01-01

    Purpose This paper aimed to investigate motor proficiency in fine and gross motor function, with a focus on reaction time (RT) and movement skill, in patients with fibromyalgia (FM) and chronic fatigue syndrome (CFS) compared to healthy controls (HC). Methods A total of 60 individuals (20 CFS, 20 FM, and 20 HC), age 19–49 years, participated in this study. Gross motor function in the lower extremity was assessed using a RT task during gait initiation in response to an auditory trigger. Fine motor function in the upper extremity was measured during a precision task (the Purdue Pegboard test) where the number of pins inserted within 30 s was counted. Results No significant differences were found between FM and CFS in any parameters. FM and CFS groups had significantly longer RT than HC in the gait initiation (p=0.001, and p=0.004 respectively). In the Purdue Pegboard test, 20% in the FM group, 15% in the CFS groups, and 0% of HC group, scored below the threshold of the accepted performance. However, there were no significant differences between FM, CFS, and HC in this task (p=0.12). Conclusion Compared to controls, both CFS and FM groups displayed significantly longer RT in the gait initiation task. Generally, FM patients showed the worst results in both tests, although no group differences were found in fine motor control, according to the Purdue Pegboard test. PMID:28223840

  14. Diagnosing schistosomiasis: where are we?

    PubMed

    Gomes, Luciana Inácia; Enk, Martin Johannes; Rabello, Ana

    2014-01-01

    In light of the World Health Organization's initiative to extend schistosomiasis morbidity and mortality control programs by including a disease elimination strategy in low endemic settings, this paper reviews diagnostic tools described during the last decades and provide an overview of ongoing efforts in making an efficient diagnostic tool available worldwide. A literature search on PubMed using the search criteria schistosomiasis and diagnosis within the period from 1978 to 2013 was carried out. Articles with abstract in English and that used laboratory techniques specifically developed for the detection of schistosomiasis in humans were included. Publications were categorized according to the methodology applied (parasitological, immunological, or molecular) and stage of development (in house development, limited field, or large scale field testing). The initial research generated 4,535 publications, of which only 643 met the inclusion criteria. The vast majority (537) of the publications focused on immunological techniques; 81 focused on parasitological diagnosis, and 25 focused on molecular diagnostic methods. Regarding the stage of development, 307 papers referred to in-house development, 202 referred to limited field tests, and 134 referred to large scale field testing. The data obtained show that promising new diagnostic tools, especially for Schistosoma antigen and deoxyribonucleic acid (DNA) detection, which are characterized by high sensitivity and specificity, are being developed. In combination with international funding initiatives these tools may result in a significant step forward in successful disease elimination and surveillance, which is to make efficient tests accessible and its large use self-sustainable for control programs in endemic countries.

  15. Measuring implicit gender-role orientation: the gender initial preference task.

    PubMed

    Stieger, Stefan; Burger, Christoph; Schiller, Franziska R; Schulze, Esther K; Voracek, Martin

    2014-01-01

    Individuals prefer their name letters over nonname letters, which is known as the name-letter effect (NLE). This research aimed to examine a possible NLE for gender-role orientation (GRO) by rating letters for their gender-typicality in an initial preference task (Gender-IPT). Indeed, a clear NLE appeared: Men rated their initials as more male-typical, whereas women rated them as more female-typical. The Gender-IPT showed good convergent validity with other direct and indirect (Gender Implicit Association Test) measures of GRO as well as predictive validity with sensation seeking and gender-typical everyday life behaviors. The Gender-IPT seems to be a useful and practical indirect measure to assess GRO in a short, convenient, and computer-independent way, complementing other indirect measures of GRO.

  16. 49 CFR 40.95 - What are the adulterant cutoff concentrations for initial and confirmation tests?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing... laboratory, you must use the cutoff concentrations for the initial and confirmation adulterant testing as...

  17. 49 CFR 40.95 - What are the adulterant cutoff concentrations for initial and confirmation tests?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing... laboratory, you must use the cutoff concentrations for the initial and confirmation adulterant testing as...

  18. 49 CFR 40.95 - What are the adulterant cutoff concentrations for initial and confirmation tests?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing... laboratory, you must use the cutoff concentrations for the initial and confirmation adulterant testing as...

  19. 49 CFR 40.95 - What are the adulterant cutoff concentrations for initial and confirmation tests?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing... laboratory, you must use the cutoff concentrations for the initial and confirmation adulterant testing as...

  20. 49 CFR 40.95 - What are the adulterant cutoff concentrations for initial and confirmation tests?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing... laboratory, you must use the cutoff concentrations for the initial and confirmation adulterant testing as...

  1. Accelerated long-term forgetting in resected and seizure-free temporal lobe epilepsy patients.

    PubMed

    Visser, M; Forn, C; Gómez-Ibáñez, A; Rosell-Negre, P; Villanueva, V; Ávila, C

    2018-03-12

    Episodic memory impairments caused by temporal lobe epilepsy (TLE) are well documented in the literature. Standard clinical episodic memory tests typically include a 30-min delayed recall test. However, in the past decade, it has become apparent that this standard test does not capture the full range of memory problems in TLE patients. Some patients perform well on a standard 30-min delayed recall test, but show Accelerated Long-term Forgetting (ALF) after 24 h. Although ALF has been investigated in patients with different types of epilepsy, current research on resected TLE patients is missing. In the present study, resected TLE patients were compared to a control group matched on initial learning. They showed normal performance on verbal recall after 30 min, but impairments became apparent after one week. Moreover, the significant interaction between participant group and memory test delay demonstrated that the patients indeed showed an acceleration in forgetting. Furthermore, ALF was present in both left and right resected TLE patients, which contradicts the presence of material-specific hemispheric differences in ALF. In addition, ALF was observed in seizure-free resected TLE patients, thereby demonstrating that this factor is not crucial for long-term memory deficits. The outcome shows that clinicians are likely to underestimate memory deficits in resected TLE patients and, therefore, advocates for the inclusion of ALF tests in standard clinical batteries for both pre- and post-surgery testing sessions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Effects of Severe Bothersome Tinnitus on Cognitive Function Measured with Standardized Tests

    PubMed Central

    Pierce, Katherine J.; Kallogjeri, Dorina; Piccirillo, Jay F.; Garcia, Keith S.; Nicklaus, Joyce E.; Burton, Harold

    2012-01-01

    Neurocognitive tests compared abilities in people with bothersome tinnitus against an age, gender, and education matched normative population. Participants between 18 and 60 years had subjective, unilateral or bilateral, non-pulsatile tinnitus for >6 months, and a Tinnitus Handicap Inventory score of ≥38. Results from a first testing session showed deficits in learning, learning rates, immediate recall of heard words, and use of a serial order encoding strategy. Initial reliance on serial order encoding and later, increased intrusion of incorrect words towards normal levels might indicate a less demanding strategy to compensate for weakness in associative memory for semantic categories. PMID:22168528

  3. In vitro antibiotic susceptibility of Dutch Mycoplasma synoviae field isolates originating from joint lesions and the respiratory tract of commercial poultry.

    PubMed

    Landman, W J M; Mevius, D J; Veldman, K T; Feberwee, A

    2008-08-01

    The in vitro susceptibility of 17 Dutch Mycoplasma synoviae isolates from commercial poultry to enrofloxacin, difloxacin, doxycycline, tylosin and tilmicosin was examined. Three isolates originated from joint lesions and 14 were from the respiratory tract. The type strain M. synoviae WVU 1853 was included as a control strain. Antibiotic susceptibility was tested quantitatively using the broth microdilution test. Based on initial and final minimum inhibitory concentration values, all tested isolates were susceptible to doxycycline, tylosin and tilmicosin. Two isolates from the respiratory tract were resistant to enrofloxacin and showed intermediate resistance to difloxacin.

  4. Blade loss transient dynamic analysis of turbomachinery

    NASA Technical Reports Server (NTRS)

    Stallone, M. J.; Gallardo, V.; Storace, A. F.; Bach, L. J.; Black, G.; Gaffney, E. F.

    1982-01-01

    This paper reports on work completed to develop an analytical method for predicting the transient non-linear response of a complete aircraft engine system due to the loss of a fan blade, and to validate the analysis by comparing the results against actual blade loss test data. The solution, which is based on the component element method, accounts for rotor-to-casing rubs, high damping and rapid deceleration rates associated with the blade loss event. A comparison of test results and predicted response show good agreement except for an initial overshoot spike not observed in test. The method is effective for analysis of large systems.

  5. Clinical characteristics of Helicobacter pylori-negative drug-negative peptic ulcer bleeding

    PubMed Central

    Chung, Woo Chul; Jeon, Eun Jung; Kim, Dae Bum; Sung, Hea Jung; Kim, Yeon-Ji; Lim, Eun Sun; Kim, Min-ah; Oh, Jung Hwan

    2015-01-01

    AIM: To investigate the clinical characteristics and outcomes of idiopathic Helicobacter pylori (H. pylori)-negative and drug-negative] peptic ulcer bleeding (PUB). METHODS: A consecutive series of patients who experienced PUB between 2006 and 2012 was retrospectively analyzed. A total of 232 patients were enrolled in this study. The patients were divided into four groups according to the etiologies of PUB: idiopathic, H. pylori-associated, drug-induced and combined (H. pylori-associated and drug-induced) types. We compared the clinical characteristics and outcomes between the groups. When the silver stain or rapid urease tests were H. pylori-negative, we obtained an additional biopsy specimen by endoscopic re-examination and performed an H. pylori antibody test 6-8 wk after the initial endoscopic examination. For a diagnosis of idiopathic PUB, a negative result of an H. pylori antibody test was confirmed. In all cases, re-bleeding was confirmed by endoscopic examination. For the risk assessment, the Blatchford and the Rockall scores were calculated for all patients. RESULTS: For PUB, the frequency of H. pylori infection was 59.5% (138/232), whereas the frequency of idiopathic cases was 8.6% (20/232). When idiopathic PUB was compared to H. pylori-associated PUB, the idiopathic PUB group showed a higher rate of re-bleeding after initial hemostasis during the hospital stay (30% vs 7.4%, P = 0.02). When idiopathic PUB was compared to drug-induced PUB, the patients in the idiopathic PUB group showed a higher rate of re-bleeding after initial hemostasis upon admission (30% vs 2.7%, P < 0.01). When drug-induced PUB was compared to H. pylori-associated PUB, the patients in the drug-induced PUB were older (68.49 ± 14.76 years vs 47.83 ± 15.15 years, P < 0.01) and showed a higher proportion of gastric ulcer (77% vs 49%, P < 0.01). However, the Blatchford and the Rockall scores were not significantly different between the two groups. Among the patients who experienced drug-induced PUB, no significant differences were found with respect to clinical characteristics, irrespective of H. pylori infection. CONCLUSION: Idiopathic PUB has unique clinical characteristics such as re-bleeding after initial hemostasis upon admission. Therefore, these patients need to undergo close surveillance upon admission. PMID:26229405

  6. Clinical characteristics of Helicobacter pylori-negative drug-negative peptic ulcer bleeding.

    PubMed

    Chung, Woo Chul; Jeon, Eun Jung; Kim, Dae Bum; Sung, Hea Jung; Kim, Yeon-Ji; Lim, Eun Sun; Kim, Min-Ah; Oh, Jung Hwan

    2015-07-28

    To investigate the clinical characteristics and outcomes of idiopathic Helicobacter pylori (H. pylori)-negative and drug-negative] peptic ulcer bleeding (PUB). A consecutive series of patients who experienced PUB between 2006 and 2012 was retrospectively analyzed. A total of 232 patients were enrolled in this study. The patients were divided into four groups according to the etiologies of PUB: idiopathic, H. pylori-associated, drug-induced and combined (H. pylori-associated and drug-induced) types. We compared the clinical characteristics and outcomes between the groups. When the silver stain or rapid urease tests were H. pylori-negative, we obtained an additional biopsy specimen by endoscopic re-examination and performed an H. pylori antibody test 6-8 wk after the initial endoscopic examination. For a diagnosis of idiopathic PUB, a negative result of an H. pylori antibody test was confirmed. In all cases, re-bleeding was confirmed by endoscopic examination. For the risk assessment, the Blatchford and the Rockall scores were calculated for all patients. For PUB, the frequency of H. pylori infection was 59.5% (138/232), whereas the frequency of idiopathic cases was 8.6% (20/232). When idiopathic PUB was compared to H. pylori-associated PUB, the idiopathic PUB group showed a higher rate of re-bleeding after initial hemostasis during the hospital stay (30% vs 7.4%, P = 0.02). When idiopathic PUB was compared to drug-induced PUB, the patients in the idiopathic PUB group showed a higher rate of re-bleeding after initial hemostasis upon admission (30% vs 2.7%, P < 0.01). When drug-induced PUB was compared to H. pylori-associated PUB, the patients in the drug-induced PUB were older (68.49 ± 14.76 years vs 47.83 ± 15.15 years, P < 0.01) and showed a higher proportion of gastric ulcer (77% vs 49%, P < 0.01). However, the Blatchford and the Rockall scores were not significantly different between the two groups. Among the patients who experienced drug-induced PUB, no significant differences were found with respect to clinical characteristics, irrespective of H. pylori infection. Idiopathic PUB has unique clinical characteristics such as re-bleeding after initial hemostasis upon admission. Therefore, these patients need to undergo close surveillance upon admission.

  7. 78 FR 63516 - Initial Test Program of Emergency Core Cooling Systems for New Boiling-Water Reactors

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-24

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0134] Initial Test Program of Emergency Core Cooling....79.1, ``Initial Test Program of Emergency Core Cooling Systems for New Boiling-Water Reactors.'' This... emergency core cooling systems (ECCSs) for boiling- water reactors (BWRs) whose licenses are issued after...

  8. 14 CFR 91.1065 - Initial and recurrent pilot testing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Initial and recurrent pilot testing... Ownership Operations Program Management § 91.1065 Initial and recurrent pilot testing requirements. (a) No program manager or owner may use a pilot, nor may any person serve as a pilot, unless, since the beginning...

  9. 14 CFR 91.1065 - Initial and recurrent pilot testing requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Initial and recurrent pilot testing... Ownership Operations Program Management § 91.1065 Initial and recurrent pilot testing requirements. (a) No program manager or owner may use a pilot, nor may any person serve as a pilot, unless, since the beginning...

  10. The tolerance efficiency of Panicum maximum and Helianthus annuus in TNT-contaminated soil and nZVI-contaminated soil.

    PubMed

    Jiamjitrpanich, Waraporn; Parkpian, Preeda; Polprasert, Chongrak; Laurent, François; Kosanlavit, Rachain

    2012-01-01

    This study was designed to compare the initial method for phytoremediation involving germination and transplantation. The study was also to determine the tolerance efficiency of Panicum maximum (Purple guinea grass) and Helianthus annuus (Sunflower) in TNT-contaminated soil and nZVI-contaminated soil. It was found that the transplantation of Panicum maximum and Helianthus annuus was more suitable than germination as the initiate method of nano-phytoremediation potting test. The study also showed that Panicum maximum was more tolerance than Helianthus annuus in TNT and nZVI-contaminated soil. Therefore, Panicum maximum in the transplantation method should be selected as a hyperaccumulated plant for nano-phytoremediation potting tests. Maximum tolerance dosage of Panicum maximum to TNT-concentration soil was 320 mg/kg and nZVI-contaminated soil was 1000 mg/kg in the transplantation method.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lincoln, D.E.

    Preliminary analysis of two populations of Artemisia tridentata compared leaf chemical and physiological characteristics which influence herbivores. The proportion of sixteen of the volatile compounds differed significantly between the two populations; however, total yield of volatiles did not. This initial survey established the reliability of the procedure to quantitatively monitor plant responses to CO/sub 2/ enrichment and suggests that test samples be restricted to a single population. Four sesquiterpene lactones have been selected for the experimental quantitative HPLC analysis; all peaks have been assigned identities and have demonstrated high degree of reproducibility. Growth of Artemisia under high and low lightmore » at three CO/sub 2/ levels demonstrated that this species also undergoes a ''dilution'' of the leaf carbon content and is useful as test species for herbivory response to CO/sub 2/ induced effects. The initial experiment also showed that high irradiance is a necessary growth condition. 10 refs.« less

  12. Slow fatigue testing of titanium grade 29 in air and seawater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atteraas, L.; Hersvik, G.; Solbakken, H.

    1999-07-01

    ASTM Grade 29 titanium has been fatigue tested in air and seawater at 110 C at a low frequency. The possible influence of seawater is completely masked by the fact that all the specimens of welded titanium, and most of the parent metal samples, had internal fracture initiations. Compared to the parent metal, the welded pipe specimens (5G orbital TIG) had a significantly lower fatigue life at the relatively high cyclic stress levels employed ({sigma}{sub max} = 0.85 {sigma}{sub y}). This is attributed to the presence of pores. Fractographic studies of failed weld metal specimens indicate that the fracture initiationmore » takes place in the material immediately surrounding a pore, with an abrupt crack formation, marking the beginning of the crack growth phase. The duration of the crack initiation phase shows large variations, whereas the growth phase duration varies little.« less

  13. Simplified approach to the mixed time-averaging semiclassical initial value representation for the calculation of dense vibrational spectra

    NASA Astrophysics Data System (ADS)

    Buchholz, Max; Grossmann, Frank; Ceotto, Michele

    2018-03-01

    We present and test an approximate method for the semiclassical calculation of vibrational spectra. The approach is based on the mixed time-averaging semiclassical initial value representation method, which is simplified to a form that contains a filter to remove contributions from approximately harmonic environmental degrees of freedom. This filter comes at no additional numerical cost, and it has no negative effect on the accuracy of peaks from the anharmonic system of interest. The method is successfully tested for a model Hamiltonian and then applied to the study of the frequency shift of iodine in a krypton matrix. Using a hierarchic model with up to 108 normal modes included in the calculation, we show how the dynamical interaction between iodine and krypton yields results for the lowest excited iodine peaks that reproduce experimental findings to a high degree of accuracy.

  14. Barriers to and acceptability of provider-initiated HIV testing and counselling and adopting HIV-prevention behaviours in rural Uganda: a qualitative study.

    PubMed

    Kiene, Susan M; Sileo, Katelyn; Wanyenze, Rhoda K; Lule, Haruna; Bateganya, Moses H; Jasperse, Joseph; Nantaba, Harriet; Jayaratne, Kia

    2015-02-01

    In Uganda, a nationwide scale-up of provider-initiated HIV testing and counselling presents an opportunity to deliver HIV-prevention services to large numbers of people. In a rural Ugandan hospital, focus group discussions and key informant interviews were conducted with outpatients receiving provider-initiated HIV testing and counselling and staff to explore the HIV-prevention information, motivation and behavioural skills strengths and weaknesses, and community-level and structural barriers to provider-initiated HIV testing and counselling acceptability and HIV prevention among this population. Strengths and weakness occurred at all levels, and results suggest brief client-centred interventions during provider-initiated HIV testing and counselling may be an effective approach to increase prevention behaviours in outpatient settings. © The Author(s) 2013.

  15. Component qualification and initial build of the AGT 100 advanced automotive gas turbine

    NASA Technical Reports Server (NTRS)

    Johnson, R. A.

    1983-01-01

    In advance of initial dynamometer testing of the AGT 100 engine, all prime components and subsystems were bench/rig tested. Included were compressor, combustor, turbines, regenerator, ceramic components, and electronic control system. Results are briefly reviewed. Initial engine buildup was completed and rolled-out for test cell installation in July 1982. Shakedown testing included motoring and sequential firing of the combustor's three fuel nozzles.

  16. Predictors of refusal of provider initiated HIV testing among clients visiting adult outpatient departments in Jimma town, Oromia Region, Ethiopia: unmatched case control study

    PubMed Central

    Lemu, Yohannes Kebede; Koricha, Zewdie Birhanu; Gebretsadik, Lakew Abebe; Roro, Ameyu Godesso

    2012-01-01

    Background Currently, provider-initiated human immunodeficiency virus (HIV) testing (PIHT) in health facilities is one of the strategies to advance HIV testing and related services. However, many HIV infected clients are missing the opportunities. This study intends to identify predictors of refusal of PIHT among clients visiting adult outpatient departments (OPDs) in Jimma town. Methods An unmatched case control study was conducted among 296 clients: 149 cases refusing HIV testing and 147 controls accepting HIV testing. The study recruited clients from OPDs of four public health facilities between March 6 and April 8, 2011 using consecutive sampling. The study instrument was adapted mainly considering health belief model (HBM). Jimma University ethical committee reviewed the study protocol. Data were collected by face-to-face interview and analyzed using SPSS Statistics (IBM Corporation, Somers, NY) software, version 16.0. Data were subjected to factor and reliability analysis. For prediction analysis, the study used logistic regression and odds ratio (OR) with 95% confidence interval (CI). To see the effects among HBM constructs, the study used standardized beta (β) coefficients at P < 0.05. Results The study findings showed adjusted protective effects on refusal of PIHT for residence outside study town [adjusted OR (AOR) (95% CI) = 0.41 (0.22–0.79)] and higher scores of perceived benefit of early testing [AOR (95% CI)] = 0.86 (0.69–0.99)], self efficacy to live with HIV [AOR (95% CI) = 0.79 (0.66–0.93)], nondisclosure agreement [AOR (95% CI) = 0.74 (0.58–0.93)], perceived explicitness of opt-out right during initiation [AOR (95% CI) = 0.74 (0.56–0.98)] and clients’ perceptions of selective initiation of HIV suspected [AOR (95% CI) = 0.54 (0.41–0.73)]. On the other hand, report of recent testing [AOR (95% CI) = 3.82 (1.71–8.55)] and perceived unpreparedness for testing [AOR (95% CI) = 1.86 (1.57–2.21)] aggravated refusal of PIHT. Exposure to cues to testing significantly reduced perceived barriers [β (P) = −0.05 (0.037)]. Conclusion Clients’ perceived barriers: feeling of unpreparedness for testing strongly aggravated refusal of test. Enhanced self-efficacy to live with HIV and presence of cues to HIV testing would reduce unpreparedness and protect from refusing PIHT. PMID:22904647

  17. Effects of feeding a diet containing Gymnema sylvestre extract: Attenuating progression of obesity in C57BL/6J mice.

    PubMed

    Kim, Hyeon-Jeong; Hong, Seong-Ho; Chang, Seung-Hee; Kim, Sanghwa; Lee, Ah Young; Jang, Yoonjeong; Davaadamdin, Orkhonselenge; Yu, Kyeong-Nam; Kim, Ji-Eun; Cho, Myung-Haing

    2016-05-01

    To investigate the effect of Gymnema sylvestre extract (GS) on initial anti-obesity, liver injury, and glucose homeostasis induced by a high-fat diet (HFD). The dry powder of GS was extracted with methanol, and gymnemic acid was identified by high performance liquid chromatography as deacyl gymnemic acid. Male C57BL/6J mice that fed on either a normal diet, normal diet containing 1 g/kg GS (CON+GS), HFD, or HFD containing 1.0 g/kg GS (HFD + GS) for 4 weeks were used to test the initial anti-obesity effect of GS. Body weight gain and food intake, and serum levels about lipid and liver injury markers were measured. Histopathology of adipose tissue and liver stained with hematoxylin and eosin (H&E) and oil-red O were analyzed. After 4 weeks of GS extract feeding, intraperitoneal glucose tolerance test (IPGTT) was performed. The methanol extracts of GS exerted significant anti-obesity effects in HFD + GS group. They decreased body weight gain, a lower food and energy efficiency ratio, and showed lower serum levels of total cholesterol (TC), triglyceride (TG), low-density lipoprotein (LDL)-cholesterol, very-low density lipoprotein (VLDL)-cholesterol and leptin compared with the HFD group. The decreases of abdominal as well as epididymal fat weight and adipocyte hypertrophy, lipid droplets in liver, and serum levels of aspartate aminotransferase (AST) and alanine transaminase (ALT) were also observed. The CON + GS group showed an effect of glucose homeostasis compared to the CON group. This study shows that GS provide the possibility as a key role in an initial anti-obesity effects feeding with a HFD. Copyright © 2016 Hainan Medical College. Production and hosting by Elsevier B.V. All rights reserved.

  18. The initial tolerance to sub-lethal Cd exposure is the same among ten naïve pond populations of Daphnia magna, but their micro-evolutionary potential to develop resistance is very different.

    PubMed

    Messiaen, Marlies; Janssen, Colin Roger; De Meester, Luc; De Schamphelaere, Karel André Clara

    2013-11-15

    Genetic variation complicates predictions of both the initial tolerance and the long-term (micro-evolutionary) response of natural Daphnia populations to chemical stressors from results of standard single-clone laboratory ecotoxicity tests. In order to investigate possible solutions to this problem, we aimed to compare the initial sub-lethal tolerance to Cd of 10 naïve natural pond populations of Daphnia magna as well as their evolutionary potential to develop increased resistance. We did so by measuring reproductive performance of 120 clones, i.e. 12 clones hatched from the recent dormant egg bank of each of 10 populations, both in absence (Cd-free control) and presence of 4.4 μg Cd/L. We show that the initial tolerance, defined as the reproductive performance of individuals of the first generation exposed to Cd relative to that in a Cd-free control was not significantly different among the 10 studied pond populations and averaged 0.82 ± 0.04 over these populations. Moreover, these populations' initial tolerances were also not significantly different from the mean initial tolerance of 0.87 ± 0.08 at 4.0 μg Cd/L measured for a group of 7 often-used laboratory clones, collected from a range of European ecotoxicity testing laboratories. This indicates that the initial response of naïve natural pond populations to sub-lethal Cd can be relatively accurately predicted from ecotoxicity test data from only a handful of laboratory clones. We then used estimates of broad-sense heritability of Cd tolerance (H(2)) - based on the same dataset - as a proxy of these populations' capacities to evolutionarily respond to Cd in terms of the development of increased resistance, which is here defined as the increase with time of the frequency of clones with a higher Cd tolerance in the population (accompanied with an increase of mean Cd-tolerance of the population above the initial tolerance). We show that the populations' estimated H(2) values of Cd-tolerance cover almost the entire theoretically possible range, ranging from not significantly different from zero (for five populations) to between 0.48 and 0.81 (for the five other populations). This indicates that, unlike the initial tolerance to Cd, the (long-term) micro-evolutionary response to Cd may be very different among natural pond populations. Therefore, we conclude that it may be very difficult to predict the long-term response of an unstudied population to chemical stress from tolerance data on a sample of other populations. It is therefore suggested that new methods for forecasting long-term responses should be explored, such as the development of predictive models based on the combination of population-genomic and tolerance time-series data. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Could situational judgement tests be used for selection into dental foundation training?

    PubMed

    Patterson, F; Ashworth, V; Mehra, S; Falcon, H

    2012-07-13

    To pilot and evaluate a machine-markable situational judgement test (SJT) designed to select candidates into UK dental foundation training. Single centre pilot study. UK postgraduate deanery in 2010. Seventy-four candidates attending interview for dental foundation training in Oxford and Wessex Deaneries volunteered to complete the situational judgement test. The situational judgement test was developed to assess relevant professional attributes for dentistry (for example, empathy and integrity) in a machine-markable format. Test content was developed by subject matter experts working with experienced psychometricians. Evaluation of psychometric properties of the pilot situational judgement test (for example, reliability, validity and fairness). Scores in the dental foundation training selection process (short-listing and interviews) were used to examine criterion-related validity. Candidates completed an evaluation questionnaire to examine candidate reactions and face validity of the new test. Forty-six candidates were female and 28 male; mean age was 23.5-years-old (range 22-32). Situational judgement test scores were normally distributed and the test showed good internal reliability when corrected for test length (α = 0.74). Situational judgement test scores positively correlated with the management, leadership and professionalism interview (N = 50; r = 0.43, p <0.01) but not with the clinical skills interview, providing initial evidence of criterion-related validity as the situational judgement test is designed to test non-cognitive professional attributes beyond clinical knowledge. Most candidates perceived the situational judgement test as relevant to dentistry, appropriate for their training level, and fair. This initial pilot study suggests that a situational judgement test is an appropriate and innovative method to measure professional attributes (eg empathy and integrity) for selection into foundation training. Further research will explore the long-term predictive validity of the situational judgement test once candidates have entered training.

  20. Enhancing the fathead minnow fish embryo toxicity test: Optimizing embryo production and assessing the utility of additional test endpoints.

    PubMed

    Roush, Kyle S; Krzykwa, Julie C; Malmquist, Jacob A; Stephens, Dane A; Sellin Jeffries, Marlo K

    2018-05-30

    The fathead minnow fish embryo toxicity (FET) test has been identified as a potential alternative to toxicity test methods that utilize older fish. However, several challenges have been identified with the fathead minnow FET test, including: 1) difficulties in obtaining appropriately-staged embryos for FET test initiation, 2) a paucity of data comparing fathead minnow FET test performance to the fathead minnow larval growth and survival (LGS) test and 3) a lack of sublethal endpoints that could be used to estimate chronic toxicity and/or predict adverse effects. These challenges were addressed through three study objectives. The first objective was to optimize embryo production by assessing the effect of breeding group composition (number of males and females) on egg production. Results showed that groups containing one male and four females produced the largest clutches, enhancing the likelihood of procuring sufficient numbers of embryos for FET test initiation. The second study objective was to compare the performance of the FET test to that of the fathead minnow LGS test using three reference toxicants. The FET and LGS tests were similar in their ability to predict the acute toxicity of sodium chloride and ethanol, but the FET test was found to be more sensitive than the LGS test for sodium dodecyl sulfate. The last objective of the study was to evaluate the utility and practicality of several sublethal metrics (i.e., growth, developmental abnormalities and growth- and stress-related gene expression) as FET test endpoints. Developmental abnormalities, including pericardial edema and hatch success, were found to offer the most promise as additional FET test endpoints, given their responsiveness, potential for predicting adverse effects, ease of assessment and low cost of measurement. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Early Verb Learning: How Do Children Learn How to Compare Events?

    PubMed Central

    Childers, Jane B.; Parrish, Rebecca; Olson, Christina V.; Burch, Clare; Fung, Gavin; McIntyre, Kevin

    2015-01-01

    An important problem verb learners must solve is how to extend verbs. Children could use cross-situational information to guide their extensions, however comparing events is difficult. Two studies test whether children benefit from initially seeing a pair of similar events (‘progressive alignment’) while learning new verbs, and whether this influence changes with age. In Study 1, 2 ½- and 3 ½-year-old children participated in an interactive task. Children who saw a pair of similar events and then varied events were able to extend verbs at test, differing from a control group; children who saw two pairs of varied events did not differ from the control group. In Study 2, events were presented on a monitor. Following the initial pair of events that varied by condition, a Tobii x120 eye tracker recorded 2 ½-, 3 ½- and 4 ½-year-olds’ fixations to specific elements of events (AOIs) during the second pair of events, which were the same across conditions. After seeing the pair of events that were highly similar, 2 ½-year-olds showed significantly longer fixation durations to agents and to affected objects as compared to the all varied condition. At test, 3 ½-year-olds were able to extend the verb, but only in the progressive alignment condition. These results are important because they show children’s visual attention to relevant elements in dynamic events is influenced by their prior comparison experience, and they show that young children benefit from seeing similar events as they learn to compare events to each other. PMID:27092030

  2. Repeat Chlamydia trachomatis testing among heterosexual STI outpatient clinic visitors in the Netherlands: a longitudinal study.

    PubMed

    Visser, Maartje; van Aar, Fleur; Koedijk, Femke D H; Kampman, Carolina J G; Heijne, Janneke C M

    2017-12-20

    Chlamydia infections are common in both men and women, are often asymptomatic and can cause serious complications. Repeat testing in high-risk groups is therefore indicated. In the Netherlands, guidelines on repeat chlamydia testing differ between testing facilities, and knowledge on repeat testing behaviour is limited. Here, we analyse the current repeat testing behaviour of heterosexual STI clinic visitors, and aim to identify groups for which repeat testing advice could be advantageous. Longitudinal surveillance data from all Dutch STI outpatient clinics were used, which included all STI clinic consultations carried out among heterosexual men and women between June 2014 and December 2015. Repeat testing was defined as returning to the same STI clinic between 35 days and 12 months after initial consultation. We calculated chlamydia positivity at repeat test stratified by initial test result and time between consultations. Logistic regression analyses were used to identify predictors of repeat testing, and predictors of having a chlamydia positive repeat test. In total, 140,486 consultations in 75,487 women and 46,286 men were available for analyses. Overall, 15.4% of women and 11.1% of men returned to the STI clinic within the study period. Highest chlamydia positivity at repeat test was seen 3-5 months after initial positive test. Among both women and men, repeat testing was associated with non-Western ethnicity, having had more than two sex partners in the past 6 months, reporting STI symptoms, having a history of STI, and having a chlamydia positive initial test. Among repeat testers, chlamydia positive repeat test was most strongly associated with younger age, followed by a chlamydia positive initial test. Repeat testing most often resulted in a positive test result among young heterosexuals (<25) and heterosexuals of any age with a chlamydia infection at the initial consultation. Further efforts are needed to determine optimal repeat testing strategies.

  3. Algebraic method for parameter identification of circuit models for batteries under non-zero initial condition

    NASA Astrophysics Data System (ADS)

    Devarakonda, Lalitha; Hu, Tingshu

    2014-12-01

    This paper presents an algebraic method for parameter identification of Thevenin's equivalent circuit models for batteries under non-zero initial condition. In traditional methods, it was assumed that all capacitor voltages have zero initial conditions at the beginning of each charging/discharging test. This would require a long rest time between two tests, leading to very lengthy tests for a charging/discharging cycle. In this paper, we propose an algebraic method which can extract the circuit parameters together with initial conditions. This would theoretically reduce the rest time to 0 and substantially accelerate the testing cycles.

  4. The effect of anti-phase domain size on the ductility of a rapidly solidified Ni3Al-Cr alloy

    NASA Technical Reports Server (NTRS)

    Carro, G.; Bertero, G. A.; Wittig, J. E.; Flanagan, W. F.

    1989-01-01

    Tensile tests on splat-quenched Ni3Al-Cr alloys showed a sharp decrease in ductility with long-time annealing. The growth of the initially very-fine-size anti-phase domains showed a tenuous correlation with ductility up to a critical size, where ductility was lost. The grain size was relatively unaffected by these annealing treatments, but the grain-boundary curvature decreased, implying less toughness. An important observation was that, for the longest annealing time, a chromium-rich precipitate formed, which the data indicate could be a boride. Miniaturized tensile tests were performed on samples which were all obtained from the same splat-quenched foil, and the various domain sizes were controlled by subsequent annealing treatments.

  5. Aging memories: differential decay of episodic memory components.

    PubMed

    Talamini, Lucia M; Gorree, Eva

    2012-05-17

    Some memories about events can persist for decades, even a lifetime. However, recent memories incorporate rich sensory information, including knowledge on the spatial and temporal ordering of event features, while old memories typically lack this "filmic" quality. We suggest that this apparent change in the nature of memories may reflect a preferential loss of hippocampus-dependent, configurational information over more cortically based memory components, including memory for individual objects. The current study systematically tests this hypothesis, using a new paradigm that allows the contemporaneous assessment of memory for objects, object pairings, and object-position conjunctions. Retention of each memory component was tested, at multiple intervals, up to 3 mo following encoding. The three memory subtasks adopted the same retrieval paradigm and were matched for initial difficulty. Results show differential decay of the tested episodic memory components, whereby memory for configurational aspects of a scene (objects' co-occurrence and object position) decays faster than memory for featured objects. Interestingly, memory requiring a visually detailed object representation decays at a similar rate as global object recognition, arguing against interpretations based on task difficulty and against the notion that (visual) detail is forgotten preferentially. These findings show that memories undergo qualitative changes as they age. More specifically, event memories become less configurational over time, preferentially losing some of the higher order associations that are dependent on the hippocampus for initial fast encoding. Implications for theories of long-term memory are discussed.

  6. [Fatal mitral valve endocarditis by Erysipelothrix rhusiopathiae].

    PubMed

    Vallespi, G V; Pipet, D A; Mattoni, S A; Lopardo, H A

    2005-01-01

    A fatal case of Erysipelothrix rhusiopathiae mitral valve endocarditis is described in a 45 years old male, with a history of chronic alcohol abuse and without animals contact. He presented intermittent fever, polyarthralgia, weight loss, and low back pain. In blood cultures (2 bottles), gram-positive pleomorphic rods grew after 48 hours of incubation. The subculture on blood agar media showed a small, alpha-hemolytic colony, catalase and oxidase negative, PYR and LAP positive and the production of H2S in triple sugar iron agar, was demonstrated. The isolate was initially identified as E. rhusiopathiae, and confirmed by API Coryne (BioMérieux). On the basis of these findings and a transthoracic echocardiogram, an endocarditis was confirmed. Intravenous ampicillin and gentamicin treatment was initiated. The patient became afever, nevertheless he died on day 19 after admission as a consequence of acute pulmonary edema. Susceptibility testing by E-test showed that the microorganism was resistant to vancomycin and gentamicin, and susceptible to penicillin and cefotaxime. We emphasize the importance to consider the isolates of gram-positive pleomorphic rods, catalase and oxidase negative, and the addition of H2S production test in TSI medium. Vancomycin-resistance helps in the identification, and to establish the correct antimicrobial therapy. Although E. rhusiopathiae is usually reported as an occupational pathogen, the contact with pigs and other farm animals may be underestimated.

  7. Increase in fluoroscopic radiation dose in successive sessions of multistage Onyx embolization of brain arteriovenous malformations compared with the first session.

    PubMed

    Sheen, Jae Jon; Jiang, Yuan Yuan; Kim, Young Eun; Maeng, Jun Young; Kim, Tae-Il; Lee, Deok Hee

    2018-03-23

    Onyx embolization is a treatment for brain arteriovenous malformations (AVMs). However, multistage embolization usually involves the presence of radiodense Onyx cast from the previous sessions, which may influence the fluoroscopic radiation dose. We compared the fluoroscopic dose between the initial and final embolization sessions. From January 2014 to September 2016, 18 patients underwent multistage Onyx embolization (more than twice) for brain AVMs. The total fluoroscopic duration (minutes), dose-area product (DAP, Gy×cm 2 ), and cumulative air kerma (CAK, mGy) of both the frontal and lateral planes were obtained. We compared the frontal and lateral fluoroscopic dose rates (dose/time) of the final embolization session with those of the initial session. The relationship between the injected Onyx volume and radiation dose was tested. The initial and final procedures on the frontal plane showed significantly different fluoroscopic dose rates (DAP: initial 0.668 Gy×cm 2 /min, final 0.848 Gy×cm 2 /min, P=0.02; CAK: initial 12.7 mGy/min, final 23.1 mGy/min, P=0.007). Those on the lateral plane also showed a similar pattern (DAP: initial 0.365 Gy×cm 2 /min, final 0.519 Gy×cm 2 /min, P=0.03; CAK: initial 6.2 mGy/min, final 12.9 mGy/min, P=0.01). The correlation between the cumulative Onyx volume (vials) and radiation dose ratio of both planes showed an increasing trend (rho 0.4325-0.7053; P=0.0011-0.0730). Owing to the automatic exposure control function during fluoroscopy, successive Onyx embolization procedures increase the fluoroscopic radiation dose in multistage brain AVM embolization because of the presence of radiodense Onyx mass. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Exploring the cause of initially reactive bovine brains on rapid tests for BSE

    PubMed Central

    Dudas, Sandor; James, Jace; Anderson, Renee; Czub, Stefanie

    2015-01-01

    ABSTRACT Bovine spongiform encephalopathy (BSE) is an invariably fatal prion disease of cattle. The identification of the zoonotic potential of BSE prompted safety officials to initiate surveillance testing for this disease. In Canada, BSE surveillance is primarily focused on high risk cattle including animals which are dead, down and unable to rise, diseased or distressed. This targeted surveillance results in the submission of brain samples with a wide range of tissue autolysis and associated contaminants. These contaminants have the potential to interfere with important steps of surveillance tests resulting in initially positive test results requiring additional testing to confirm the disease status of the animal. The current tests used for BSE screening in Canada utilize the relative protease resistance of the prion protein gained when it misfolds from PrPC to PrPSc as part of the disease process. Proteinase K completely digests PrPC in normal brains, but leaves most of the PrPSc in BSE positive brains intact which is detected using anti-prion antibodies. These tests are highly reliable but occasionally give rise to initially reactive/false positive results. Test results for these reactive samples were close to the positive/negative cut-off on a sub set of test platforms. This is in contrast to all of the previous Canadian positive samples whose numeric values on these same test platforms were 10 to 100 fold greater than the test positive/negative cut-off. Here we explore the potential reason why a sample is repeatedly positive on a sub-set of rapid surveillance tests, but negative on other test platforms. In order to better understand and identify what might cause these initial reactions, we have conducted a variety of rapid and confirmatory assays as well as bacterial isolation and identification on BSE positive, negative and initially reactive samples. We observed high levels of viable bacterial contamination in initially reactive samples suggesting that the reactivity may be related to bacterial factors. Several bacteria isolated from the initially reactive samples have characteristics of biofilm forming bacteria and this extracellular matrix might play a role in preventing complete digestion of PrPC in these samples. PMID:26689488

  9. Color discrimination across four life decades assessed by the Cambridge Colour Test.

    PubMed

    Paramei, Galina V

    2012-02-01

    Color discrimination was estimated using the Cambridge Colour Test (CCT) in 160 normal trichromats of four life decades, 20-59 years of age. For each age cohort, medians and tolerance limits of the CCT parameters are tabulated. Compared across the age cohorts (Kruskal-Wallis test), the Trivector test showed increases in the three vectors, Protan, Deutan, and Tritan, with advancing age; the Ellipses test revealed significant elongation of the major axes of all three ellipses but no changes in either the axis ratio or the angle of the ellipse major axis. Multiple comparisons (Mann-Whitney test) between the cohorts of four age decades (20+,…,50+) revealed initial benign deterioration of color discrimination in the 40+ decade, as an incremental loss of discrimination along the Deutan axis (Trivector test), and in the 50+ decade, as an elongation of the major axes of all three ellipses (Ellipses test). © 2012 Optical Society of America

  10. Affordable Electro-Magnetic Interference (EMI) Testing on Large Space Vehicles

    NASA Technical Reports Server (NTRS)

    Aldridge, Edward; Curry, Bruce; Scully, Robert

    2015-01-01

    Objective: Perform System-Level EMI testing of the Orion Exploration Flight Test-1 (EFT-1) spacecraft in situ in the Kennedy Space Center's Neil Armstrong Operations & Checkout (O&C) Facility in 6 days. The only way to execute the system-level EMI testing and meet this schedule challenge was to perform the EMI testing in situ in the Final Assembly & System Test (FAST) Cell in a reverberant mode, not the direct illumination mode originally planned. This required the unplanned construction of a Faraday Cage around the vehicle and FAST Cell structure. The presence of massive steel platforms created many challenges to developing an efficient screen room to contain the RF energy and yield an effective reverberant chamber. An initial effectiveness test showed marginal performance, but improvements implemented afterward resulted in the final test performing surprisingly well! The paper will explain the design, the challenges, and the changes that made the difference in performance!

  11. Recalling a witnessed event increases eyewitness suggestibility: the reversed testing effect.

    PubMed

    Chan, Jason C K; Thomas, Ayanna K; Bulevich, John B

    2009-01-01

    People's later memory of an event can be altered by exposure to misinformation about that event. The typical misinformation paradigm, however, does not include a recall test prior to the introduction of misinformation, contrary to what real-life eyewitnesses encounter when they report to a 911 operator or crime-scene officer. Because retrieval is a powerful memory enhancer (the testing effect), recalling a witnessed event prior to receiving misinformation about it should reduce eyewitness suggestibility. We show, however, that immediate cued recall actually exacerbates the later misinformation effect for both younger and older adults. The reversed testing effect we observed was based on two mechanisms: First, immediate cued recall enhanced learning of the misinformation; second, the initially recalled details became particularly susceptible to interference from later misinformation, a finding suggesting that even human episodic memory may undergo a reconsolidation process. These results show that real-life eyewitness memory may be even more susceptible to misinformation than is currently envisioned.

  12. Ineffective initiation contributes to deficient verbal and non-verbal fluency in patients with schizophrenia.

    PubMed

    Krukow, Paweł; Harciarek, Michał; Morylowska-Topolska, Justyna; Karakuła-Juchnowicz, Hanna; Jonak, Kamil

    2017-09-01

    Patients with schizophrenia (SCH) show impaired verbal and non-verbal fluency. However, these individuals' fluctuations in words or designs generation efficiency over time, a phenomenon that may significantly affect fluency, have never been studied. Thus, the aim of this research was to investigate if individuals with SCH may present with alternations in the dynamics of the information production and its control as well as to test if the potential abnormalities in this regard might affect these patients' overall performance on both verbal and non-verbal fluency tasks. Forty-four patients with SCH and 40 healthy controls (HC) completed both verbal (phonological, semantic) and non-verbal fluency tests. To analyse processing efficiency changes over time, the period in which subjects had to generate words or designs (60 s) has been divided into 15-s sections. In comparison to HCs, individuals with SCH obtained significantly lower total scores for all fluency measures. Furthermore, group differences in the dynamics of the test performance also emerged, with SCH patients having a significantly worse production during the initial 15 s of each fluency task. Additionally, the initial production deficiency seen in patients with SCH has accounted for these individuals' total performance. Moreover, comparisons of errors distribution over time during the phonemic and figural fluency performance also revealed differences, suggesting there was a rapid depletion in maintaining of cognitive control in the SCH sample. Inefficient fluency in SCH may arise from a more general initiation deficits that may partly account for these patients' cognitive problems.

  13. Fear of falling is associated with prolonged anticipatory postural adjustment during gait initiation under dual-task conditions in older adults.

    PubMed

    Uemura, Kazuki; Yamada, Minoru; Nagai, Koutatsu; Tanaka, Buichi; Mori, Shuhei; Ichihashi, Noriaki

    2012-02-01

    Little is known about dynamic balance control under dual-task conditions in older adults with fear of falling (FoF). The purpose of this study was to examine the effect of FoF on anticipatory postural adjustment (APA) during gait initiation under dual-task conditions in older adults. Fifty-seven elderly volunteers (age, 79.2 [6.8] years) from the community participated in this study. Each participant was categorised into either the Fear (n=24) or No-fear (n=33) group on the basis of the presence or absence of FoF. Under single- and dual-task conditions, centre of pressure (COP) data were collected while the participants performed gait initiation trials from a starting position on a force platform. We also performed a 10-m walking test (WT), a timed up & go test (TUG), and a functional reach test (FR). The reaction and APA phases were measured from the COP data. The results showed that under the dual-task condition, the Fear group had significantly longer APA phases than the No-fear group, although no significant differences were observed between the 2 groups in the reaction and APA phases under the single-task condition and in any clinical measurements (WT, TUG, and FR). Our findings suggest that specific deficits in balance control occur in subjects with FoF during gait initiation while dual tasking, even if their physical functions are comparable to subjects without FoF. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Hereditary neuropathy with liability to pressure palsy: two cases of difficult diagnosis.

    PubMed

    Beydoun, Said R; Cho, Justin

    2013-09-01

    Hereditary neuropathy with liability to pressure palsies (HNPP) is an inherited autosomal dominant disorder that causes a polyneuropathy with predisposition for involvement at sites of compression and is often underdiagnosed or misdiagnosed due to its heterogeneity in clinical and electrophysiological presentation. We report 2 cases of HNPP, which were initially diagnosed and treated as either an acquired demyelinating disorder or alternative inherited demyelinating disorder. Thorough evaluation of repeat electrodiagnostic studies and genetic testing confirmed the diagnosis of HNPP in both cases. One case showed the classic peripheral myelin protein 22 (PMP22) deletion and the other case showed a previously reported single base pair deletion at Leu145 causing a frameshift mutation at the PMP22 gene. These cases underscore the difficulty of diagnosing HNPP, because of the variations in clinical and electrophysiological findings and reinforce the importance of a combination high index of clinical suspicion, electrodiagnostic testing, and genetic testing to make the diagnosis.

  15. Release from proactive interference in rat spatial working memory.

    PubMed

    Roberts, William A; MacDonald, Hayden; Brown, Lyn; Macpherson, Krista

    2017-09-01

    A three-phase procedure was used to produce proactive interference (PI) in one trial on an eight-arm radial maze. Rats were forced to enter four arms for reward on an initial interference phase, to then enter the four remaining arms on a target phase, and to then choose among all eight arms on a retention test, with only the arms not visited in the target phase containing reward. Control trials involved only the target phase and the retention test. Lower accuracy was found on PI trials than on control trials, but performance on PI trials significantly exceeded chance, showing some retention of target memories. Changes in temporal and reward variables between the interference, target, and retention test phases showed release from PI, but changes in context and pattern of arm entry did not. It is suggested that the release from PI paradigm can be used to understand spatial memory encoding in rats and other species.

  16. Tape recorder failure investigation

    NASA Technical Reports Server (NTRS)

    Higgins, M. D.; Loewenthal, S. H.; Carnahan, C. C.; Snyder, G. L.

    1996-01-01

    Two end-item tape recorders lost 4:1 mode data recording mode capability at less than half of their 1 6,000-cycle, 4-year operating life. Subsequent life tests on two spare recorders also experienced 4:1 mode data loss at 8,000 and 11,700 cycles. Tear down inspection after completion of the life tests showed that the tape had worn through the alfesil record and reproduce heads. An investigation was initiated to understand the cause of excessive tape head wear and the reasons why the 4:1 mode data rate, low-speed mode is more damaging than the 1:1 mode data rate, high-speed recording mode. The objective was to establish how operating conditions (tape speed, humidity, temperature, stop/start cycles) affects head life with the goal of extending head life on the remaining in-service tape recorders. Another interest was to explain why an earlier vendor life test showed capability beyond 16,000 cycles.

  17. Testing of a Microfluidic Sampling System for High Temperature Electrochemical MC&A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pereira, Candido; Nichols, Kevin

    2013-11-27

    This report describes the preliminary validation of a high-temperature microfluidic chip system for sampling of electrochemical process salt. Electroanalytical and spectroscopic techniques are attractive candidates for improvement through high-throughput sample analysis via miniaturization. Further, microfluidic chip systems are amenable to micro-scale chemical processing such as rapid, automated sample purification to improve sensor performance. The microfluidic chip was tested to determine the feasibility of the system for high temperature applications and conditions under which microfluidic systems can be used to generate salt droplets at process temperature to support development of material balance and control systems in a used fuel treatment facility.more » In FY13, the project focused on testing a quartz microchip device with molten salts at near process temperatures. The equipment was installed in glove box and tested up to 400°C using commercial thermal transfer fluids as the carrier phase. Preliminary tests were carried out with a low-melting halide salt to initially characterize the properties of this novel liquid-liquid system and to investigate the operating regimes for inducing droplet flow within candidate carrier fluids. Initial results show that the concept is viable for high temperature sampling but further development is required to optimize the system to operate with process relevant molten salts.« less

  18. Assessment of anxiety in open field and elevated plus maze using infrared thermography.

    PubMed

    Lecorps, Benjamin; Rödel, Heiko G; Féron, Christophe

    2016-04-01

    Due to their direct inaccessibility, affective states are classically assessed by gathering concomitant physiological and behavioral measures. Although such a dual approach to assess emotional states is frequently used in different species including humans, the invasiveness of procedures for physiological recordings particularly in smaller-sized animals strongly restricts their application. We used infrared thermography, a non-invasive method, to assess physiological arousal during open field and elevated plus maze tests in mice. By measuring changes in surface temperature indicative of the animals' emotional response, we aimed to improve the inherently limited and still controversial information provided by behavioral parameters commonly used in these tests. Our results showed significant and consistent thermal responses during both tests, in accordance with classical physiological responses occurring in stressful situations. Besides, we found correlations between these thermal responses and the occurrence of anxiety-related behaviors. Furthermore, initial temperatures measured at the start of each procedure (open field, elevated plus maze), which can be interpreted as a measure of the animals' initial physiological arousal, predicted the levels of activity and of anxiety-related behaviors displayed during the tests. Our results stress the strong link between physiological correlates of emotions and behaviors expressed during unconditioned fear tests. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. 40 CFR 63.5722 - How do I use the performance test data to demonstrate initial compliance?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 12 2011-07-01 2009-07-01 true How do I use the performance test data... Manufacturing Demonstrating Compliance for Open Molding Operations Controlled by Add-on Control Devices § 63.5722 How do I use the performance test data to demonstrate initial compliance? Demonstrate initial...

  20. 40 CFR 63.5722 - How do I use the performance test data to demonstrate initial compliance?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true How do I use the performance test data... Manufacturing Demonstrating Compliance for Open Molding Operations Controlled by Add-on Control Devices § 63.5722 How do I use the performance test data to demonstrate initial compliance? Demonstrate initial...

  1. 40 CFR 53.7 - Testing of methods at the initiative of the Administrator.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Testing of methods at the initiative of the Administrator. 53.7 Section 53.7 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Provisions § 53.7 Testing of methods at the initiative of the Administrator. (a) In the absence of an...

  2. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  3. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  4. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  5. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  6. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  7. Automatic Color Sorting of Hardwood Edge-Glued Panel Parts

    Treesearch

    D. Earl Kline; Richard Conners; Qiang Lu; Philip A. Araman

    1997-01-01

    This paper describes an automatic color sorting system for red oak edge-glued panel parts. The color sorting system simultaneously examines both faces of a panel part and then determines which face has the "best" color, and sorts the part into one of a number of color classes at plant production speeds. Initial test results show that the system generated over...

  8. (Re)Discovering Retrospective Miscue Analysis: An Action Research Exploration Using Recorded Readings to Improve Third-Grade Students' Reading Fluency

    ERIC Educational Resources Information Center

    Born, Melissa; Curtis, Reagan

    2013-01-01

    An action research project was undertaken focused on integrating recorded readings and Retrospective Miscue Analysis (RMA) into center-based instructional time in a third-grade classroom. Initial DIBELS test results were used to select 6 struggling readers, all of whom showed improved fluency in response to our instructional interventions. The…

  9. Building a Better Mousetrap: How Design-Based Research Was Used to Improve Homemade PowerPoint Games

    ERIC Educational Resources Information Center

    Siko, Jason P.; Barbour, Michael K.

    2016-01-01

    This paper is a review of a three-cycle, design-based research study that explored the relationship between the pedagogical research and the actual implementation of a game design project using Microsoft PowerPoint. Much of the initial literature on using homemade PowerPoint games showed no significant improvement in test scores when students…

  10. The Effects of Face Expertise Training on the Behavioral Performance and Brain Activity of Adults with High Functioning Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Faja, Susan; Webb, Sara Jane; Jones, Emily; Merkle, Kristen; Kamara, Dana; Bavaro, Joshua; Aylward, Elizabeth; Dawson, Geraldine

    2012-01-01

    The effect of expertise training with faces was studied in adults with ASD who showed initial impairment in face recognition. Participants were randomly assigned to a computerized training program involving either faces or houses. Pre- and post-testing included standardized and experimental measures of behavior and event-related brain potentials…

  11. Penrose inequality in anti-de Sitter space

    NASA Astrophysics Data System (ADS)

    Husain, Viqar; Singh, Suprit

    2017-11-01

    For asymptotically flat spacetimes the Penrose inequality gives an initial data test for the weak cosmic censorship hypothesis. We give a formulation of this inequality for asymptotically anti-de Sitter (AAdS) spacetimes, and show that the inequality holds for time asymmetric data in spherical symmetry. Our analysis is motivated by the constant-negative-spatial-curvature form of the AdS black hole metric.

  12. Giant cane propagation techniques for use in restoration of riparian forest ecosystems

    Treesearch

    Rebecca L. Sexton; James J. Zaczek; John W. Groninger; Stephen D. Fillmore; Karl W. J. Williard

    2003-01-01

    This study was initiated to determine factors important for rhizome cutting propagation of giant cane for use in canebreak restoration. Experiment I showed that greater numbers of culms were produced for rhizomes with more internodes especially when surface planted rather than buried. Experiment II determined that 76 percent of the 435 rhizomes tested produced at least...

  13. Hydrogen-induced strain localisation in oxygen-free copper in the initial stage of plastic deformation

    NASA Astrophysics Data System (ADS)

    Yagodzinskyy, Yuriy; Malitckii, Evgenii; Tuomisto, Filip; Hänninen, Hannu

    2018-03-01

    Single crystals of oxygen-free copper oriented to easy glide of dislocations were tensile tested in order to study the hydrogen effects on the strain localisation in the form of slip bands appearing on the polished specimen surface under tensile straining. It was found that hydrogen increases the plastic flow stress in Stage I of deformation. The dislocation slip localisation in the form of slip bands was observed and analysed using an online optical monitoring system and atomic force microscopy. The fine structure of the slip bands observed with AFM shows that they consist of a number of dislocation slip offsets which spacing in the presence of hydrogen is markedly reduced as compared to that in the hydrogen-free specimens. The tensile tests and AFM observations were accompanied with positron annihilation lifetime measurements showing that straining of pure copper in the presence of hydrogen results in free volume generation in the form of vacancy complexes. Hydrogen-enhanced free-volume generation is discussed in terms of hydrogen interactions with edge dislocation dipoles forming in double cross-slip of screw dislocations in the initial stage of plastic deformation of pure copper.

  14. Chemically induced graft copolymerization of 2-hydroxyethyl methacrylate onto polyurethane surface for improving blood compatibility

    NASA Astrophysics Data System (ADS)

    He, Chunli; Wang, Miao; Cai, Xianmei; Huang, Xiaobo; Li, Li; Zhu, Haomiao; Shen, Jian; Yuan, Jiang

    2011-11-01

    To improve hydrophilicity and blood compatibility properties of polyurethane (PU) film, we chemically induced graft copolymerization of 2-hydroxyethyl methacrylate (HEMA) onto the surface of polyurethane film using benzoyl peroxide as an initiator. The effects of grafting temperature, grafting time, monomer and initiator concentrations on the grafting yields were studied. The maximum grafting yield value was obtained 0.0275 g/cm2 for HEMA. Characterization of the films was carried out by attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), water contact angle measurements. ATR-FTIR data showed that HEMA was successfully grafted onto the PU films surface. Water contact angle measurement demonstrated the grafted films possessed a relatively hydrophilic surface. The blood compatibility of the grafted films was preliminarily evaluated by a platelet-rich plasma adhesion test and hemolysis test. The results of platelet adhesion experiment showed that polyurethane grafted polymerization with monomer of 2-hydroxyethyl methacrylate had good blood compatibility featured by the low platelet adhesion. Hemolysis rate of the PU-g-PHEMA films was dramatically decreased than the ungrafted PU films. This kind of new biomaterials grafted with HEMA monomers might have a potential usage for biomedical applications.

  15. Influence of Different Ceramic Systems on Marginal Misfit.

    PubMed

    Vargas, S P; Neves, A C C; Vitti, R; Amaral, M; Henrique, M N; Silva-Concílio, L R

    2017-09-01

    the aim of this study was to evaluate the marginal misfit at the interface between a ceramic coping and its abutment. Twenty-four specimens were made with solid abutments. The specimens were divided into 3 groups according to the ceramic system (n = 8): Lava (zirconia), IPS e.max Press (lithium disilicate), and IPS Empress Esthetic (leucite). All copings were cemented with resin luting agent (RelyX U200) and the marginal misfit were evaluated at 3 different times: initial, after cementation, and after mechanical cycling using a linear measuring microscope (Measuring Microscope STM-Olympus) at a magnification of 40x. All specimens were subjected to mechanical cycling (1 million cycles) by an universal testing machine (Instron 8800). The results were statistically analyzed using Analysis of Variance and Student's t-test (α = 0.05). all groups showed an increase in the marginal misfit after cementation. The lithium disilicate group demonstrated the lowest interacial gap values at each evaluation (p = 0.001). The zirconia and leucite groups showed similar interfacial gap values (initial, p = 0.244; and post cementation, p = 0.751). the cementation increase the marginal misfit, but the mechanical cycling did not influence the marginal misfit of the ceramics systems evaluated. Copyright© 2017 Dennis Barber Ltd.

  16. Insect immunity shows specificity in protection upon secondary pathogen exposure.

    PubMed

    Sadd, Ben M; Schmid-Hempel, Paul

    2006-06-20

    Immunological memory in vertebrates, conferring lasting specific protection after an initial pathogen exposure, has implications for a broad spectrum of evolutionary, epidemiological, and medical phenomena . However, the existence of specificity in protection upon secondary pathogen exposure in invertebrates remains controversial . To separate this functional phenomenon from a particular mechanism, we refer to it as specific immune priming. We investigate the presence of specific immune priming in workers of the social insect Bombus terrestris. Using three bacterial pathogens, we test whether a prior homologous pathogen exposure gives a benefit in terms of long-term protection against a later challenge, over and above a heterologous combination. With a reciprocally designed initial and second-exposure protocol (i.e., all combinations of bacteria were tested), we demonstrate, even several weeks after the clearance of a first exposure, increased protection and narrow specificity upon secondary exposure. This demonstrates that the invertebrate immune system is functionally capable of unexpectedly specific and durable induced protection. Ultimately, despite general broad differences between vertebrates and invertebrates, the ability of both immune systems to show specificity in protection suggests that their immune defenses have found comparable solutions to similar selective pressures over evolutionary time.

  17. Brainstem auditory-evoked potentials as an objective tool for evaluating hearing dysfunction in traumatic brain injury.

    PubMed

    Lew, Henry L; Lee, Eun Ha; Miyoshi, Yasushi; Chang, Douglas G; Date, Elaine S; Jerger, James F

    2004-03-01

    Because of the violent nature of traumatic brain injury, traumatic brain injury patients are susceptible to various types of trauma involving the auditory system. We report a case of a 55-yr-old man who presented with communication problems after traumatic brain injury. Initial results from behavioral audiometry and Weber/Rinne tests were not reliable because of poor cooperation. He was transferred to our service for inpatient rehabilitation, where review of the initial head computed tomographic scan showed only left temporal bone fracture. Brainstem auditory-evoked potential was then performed to evaluate his hearing function. The results showed bilateral absence of auditory-evoked responses, which strongly suggested bilateral deafness. This finding led to a follow-up computed tomographic scan, with focus on bilateral temporal bones. A subtle transverse fracture of the right temporal bone was then detected, in addition to the left temporal bone fracture previously identified. Like children with hearing impairment, traumatic brain injury patients may not be able to verbalize their auditory deficits in a timely manner. If hearing loss is suspected in a patient who is unable to participate in traditional behavioral audiometric testing, brainstem auditory-evoked potential may be an option for evaluating hearing dysfunction.

  18. A pulse-controlled modified-burst test instrument for accident-tolerant fuel cladding

    DOE PAGES

    Cinbiz, M. Nedim; Brown, Nicholas R.; Terrani, Kurt A.; ...

    2017-06-03

    Pellet-cladding mechanical interaction due to thermal expansion of nuclear fuel pellets during a reactivity-initiated accident (RIA) is a potential mechanism for failure of nuclear fuel cladding. To investigate the mechanical behavior of cladding during an RIA, we developed a mechanical pulse-controlled modified burst test instrument that simulates transient events with a pulse width from 10 to 300 ms. This paper includes validation tests of unirradiated and prehydrided ZIRLO cladding tubes. A ZIRLO cladding sample with a hydrogen content of 168 wt. ppm showed ductile behavior and failed at the maximum limits of the test setup with hoop strain to failuremore » greater than 9.2%. ZIRLO samples showed high resistance to failure even at very high hydrogen contents (1,466 wt. ppm). When the hydrogen content was increased to 1,554 wt. ppm, brittle-like behavior was observed at a hoop strain of 2.5%. Preliminary scoping tests at room temperature with FeCrAl tubes were conducted to imitate the pulse behavior of transient test reactors during integral tests. The preliminary FeCrAl tests are informative from the perspective of characterizing the test rig and supporting the design of integral tests for current and potentially accident tolerant cladding materials.« less

  19. A pulse-controlled modified-burst test instrument for accident-tolerant fuel cladding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cinbiz, M. Nedim; Brown, Nicholas R.; Terrani, Kurt A.

    Pellet-cladding mechanical interaction due to thermal expansion of nuclear fuel pellets during a reactivity-initiated accident (RIA) is a potential mechanism for failure of nuclear fuel cladding. To investigate the mechanical behavior of cladding during an RIA, we developed a mechanical pulse-controlled modified burst test instrument that simulates transient events with a pulse width from 10 to 300 ms. This paper includes validation tests of unirradiated and prehydrided ZIRLO cladding tubes. A ZIRLO cladding sample with a hydrogen content of 168 wt. ppm showed ductile behavior and failed at the maximum limits of the test setup with hoop strain to failuremore » greater than 9.2%. ZIRLO samples showed high resistance to failure even at very high hydrogen contents (1,466 wt. ppm). When the hydrogen content was increased to 1,554 wt. ppm, brittle-like behavior was observed at a hoop strain of 2.5%. Preliminary scoping tests at room temperature with FeCrAl tubes were conducted to imitate the pulse behavior of transient test reactors during integral tests. The preliminary FeCrAl tests are informative from the perspective of characterizing the test rig and supporting the design of integral tests for current and potentially accident tolerant cladding materials.« less

  20. Febuxostat-associated eosinophilic polymyositis in marginal zone lymphoma.

    PubMed

    Chahine, Georges; Saleh, Khalil; Ghorra, Claude; Khoury, Nathalie; Khalife, Nadine; Fayad, Fouad

    2017-03-01

    Febuxostat is an orally administered selective inhibitor of xanthine oxidase approved for the treatment of gout and prevention of tumor lysis syndrome. It is a relatively safe medication. Hypersensitivity reactions associated with the use of febuxostat are quite rare with only one reported case of DRESS syndrome. Recently, two case reports of rhabdomyolysis following the initiation of febuxostat were published. We hereby present the first case of rhabdomyolysis with hypereosinophilia following the administration of febuxostat to a 50-year-old patient newly diagnosed with marginal zone lymphoma. Three weeks after the initiation of febuxostat for tumor lysis syndrome prophylaxis, the patient presented with generalized weakness, diffuse myalgia and low-grade fever. Initial studies showed creatinine kinase level of 4471, hypereosinophilia of 1900/mm 3 , and LDH of 2691. All infectious and autoimmune diseases were ruled out. TSH level was normal. Muscle biopsy showed myonecrosis in addition to an eosinophilic inflammatory infiltrate in the endomysium and perimysium. Discontinuation of febuxostat led to prompt symptom resolution and normalization of blood tests eight days later. Copyright © 2016 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  1. Dynamics of representational change: entropy, action, and cognition.

    PubMed

    Stephen, Damian G; Dixon, James A; Isenhower, Robert W

    2009-12-01

    Explaining how the cognitive system can create new structures has been a major challenge for cognitive science. Self-organization from the theory of nonlinear dynamics offers an account of this remarkable phenomenon. Two studies provide an initial test of the hypothesis that the emergence of new cognitive structure follows the same universal principles as emergence in other domains (e.g., fluids, lasers). In both studies, participants initially solved gear-system problems by manually tracing the force across a system of gears. Subsequently, they discovered that the gears form an alternating sequence, thereby demonstrating a new cognitive structure. In both studies, dynamical analyses of action during problem solving predicted the spontaneous emergence of the new cognitive structure. Study 1 showed that a peak in entropy, followed by negentropy, key indicators of self-organization, predicted discovery of alternation. Study 2 replicated these effects, and showed that increasing environmental entropy accelerated discovery, a classic prediction from dynamics. Additional analyses based on the relationship between phase transitions and power-law behavior provide converging evidence. The studies provide an initial demonstration of the emergence of cognitive structure through self-organization.

  2. Students' Initial Knowledge State and Test Design: Towards a Valid and Reliable Test Instrument

    ERIC Educational Resources Information Center

    CoPo, Antonio Roland I.

    2015-01-01

    Designing a good test instrument involves specifications, test construction, validation, try-out, analysis and revision. The initial knowledge state of forty (40) tertiary students enrolled in Business Statistics course was determined and the same test instrument undergoes validation. The designed test instrument did not only reveal the baseline…

  3. Retention of Prose Following Testing with Different Types of Tests.

    ERIC Educational Resources Information Center

    Duchastel, Philippe C.

    1981-01-01

    Taking a test on a passage one has just studied is known to enhance later retention. This effect was influenced by the type of initial test used. It was evident in the case of the initial short-answer test, but not in the case of multiple choice and free recall tests. (Author/RD)

  4. Outcomes of anatomical versus functional testing for coronary artery disease.

    PubMed

    Douglas, Pamela S; Hoffmann, Udo; Patel, Manesh R; Mark, Daniel B; Al-Khalidi, Hussein R; Cavanaugh, Brendan; Cole, Jason; Dolor, Rowena J; Fordyce, Christopher B; Huang, Megan; Khan, Muhammad Akram; Kosinski, Andrzej S; Krucoff, Mitchell W; Malhotra, Vinay; Picard, Michael H; Udelson, James E; Velazquez, Eric J; Yow, Eric; Cooper, Lawton S; Lee, Kerry L

    2015-04-02

    Many patients have symptoms suggestive of coronary artery disease (CAD) and are often evaluated with the use of diagnostic testing, although there are limited data from randomized trials to guide care. We randomly assigned 10,003 symptomatic patients to a strategy of initial anatomical testing with the use of coronary computed tomographic angiography (CTA) or to functional testing (exercise electrocardiography, nuclear stress testing, or stress echocardiography). The composite primary end point was death, myocardial infarction, hospitalization for unstable angina, or major procedural complication. Secondary end points included invasive cardiac catheterization that did not show obstructive CAD and radiation exposure. The mean age of the patients was 60.8±8.3 years, 52.7% were women, and 87.7% had chest pain or dyspnea on exertion. The mean pretest likelihood of obstructive CAD was 53.3±21.4%. Over a median follow-up period of 25 months, a primary end-point event occurred in 164 of 4996 patients in the CTA group (3.3%) and in 151 of 5007 (3.0%) in the functional-testing group (adjusted hazard ratio, 1.04; 95% confidence interval, 0.83 to 1.29; P=0.75). CTA was associated with fewer catheterizations showing no obstructive CAD than was functional testing (3.4% vs. 4.3%, P=0.02), although more patients in the CTA group underwent catheterization within 90 days after randomization (12.2% vs. 8.1%). The median cumulative radiation exposure per patient was lower in the CTA group than in the functional-testing group (10.0 mSv vs. 11.3 mSv), but 32.6% of the patients in the functional-testing group had no exposure, so the overall exposure was higher in the CTA group (mean, 12.0 mSv vs. 10.1 mSv; P<0.001). In symptomatic patients with suspected CAD who required noninvasive testing, a strategy of initial CTA, as compared with functional testing, did not improve clinical outcomes over a median follow-up of 2 years. (Funded by the National Heart, Lung, and Blood Institute; PROMISE ClinicalTrials.gov number, NCT01174550.).

  5. Outcomes of Anatomical versus Functional Testing for Coronary Artery Disease

    PubMed Central

    Douglas, Pamela S.; Hoffmann, Udo; Patel, Manesh R.; Mark, Daniel B.; Al-Khalidi, Hussein R.; Cavanaugh, Brendan; Cole, Jason; Dolor, Rowena J.; Fordyce, Christopher B.; Huang, Megan; Khan, Muhammad Akram; Kosinski, Andrzej S.; Krucoff, Mitchell W.; Malhotra, Vinay; Picard, Michael H.; Udelson, James E.; Velazquez, Eric J.; Yow, Eric; Cooper, Lawton S.; Lee, Kerry L.

    2015-01-01

    BACKGROUND Many patients have symptoms suggestive of coronary artery disease (CAD) and are often evaluated with the use of diagnostic testing, although there are limited data from randomized trials to guide care. METHODS We randomly assigned 10,003 symptomatic patients to a strategy of initial anatomical testing with the use of coronary computed tomographic angiography (CTA) or to functional testing (exercise electrocardiography, nuclear stress testing, or stress echocardiography). The composite primary end point was death, myocardial infarction, hospitalization for unstable angina, or major procedural complication. Secondary end points included invasive cardiac catheterization that did not show obstructive CAD and radiation exposure. RESULTS The mean age of the patients was 60.8±8.3 years, 52.7% were women, and 87.7% had chest pain or dyspnea on exertion. The mean pretest likelihood of obstructive CAD was 53.3±21.4%. Over a median follow-up period of 25 months, a primary end-point event occurred in 164 of 4996 patients in the CTA group (3.3%) and in 151 of 5007 (3.0%) in the functional-testing group (adjusted hazard ratio, 1.04; 95% confidence interval, 0.83 to 1.29; P = 0.75). CTA was associated with fewer catheterizations showing no obstructive CAD than was functional testing (3.4% vs. 4.3%, P = 0.02), although more patients in the CTA group underwent catheterization within 90 days after randomization (12.2% vs. 8.1%). The median cumulative radiation exposure per patient was lower in the CTA group than in the functional-testing group (10.0 mSv vs. 11.3 mSv), but 32.6% of the patients in the functional-testing group had no exposure, so the overall exposure was higher in the CTA group (mean, 12.0 mSv vs. 10.1 mSv; P<0.001). CONCLUSIONS In symptomatic patients with suspected CAD who required noninvasive testing, a strategy of initial CTA, as compared with functional testing, did not improve clinical outcomes over a median follow-up of 2 years. (Funded by the National Heart, Lung, and Blood Institute; PROMISE ClinicalTrials.gov number, NCT01174550.) PMID:25773919

  6. Esophageal Candidiasis as the Initial Manifestation of Acute Myeloid Leukemia.

    PubMed

    Komeno, Yukiko; Uryu, Hideki; Iwata, Yuko; Hatada, Yasumasa; Sakamoto, Jumpei; Iihara, Kuniko; Ryu, Tomiko

    2015-01-01

    A 47-year-old woman presented with persistent dysphagia. A gastroendoscopy revealed massive esophageal candidiasis, and oral miconazole was prescribed. Three weeks later, she returned to our hospital without symptomatic improvement. She was febrile, and blood tests showed leukocytosis (137,150 /μL, blast 85%), anemia and thrombocytopenia. She was diagnosed with acute myeloid leukemia (AML). She received chemotherapy and antimicrobial agents. During the recovery from the nadir, bilateral ocular candidiasis was detected, suggesting the presence of preceding candidemia. Thus, esophageal candidiasis can be an initial manifestation of AML. Thorough examination to detect systemic candidiasis is strongly recommended when neutropenic patients exhibit local candidiasis prior to chemotherapy.

  7. Acoustic emission analysis of fiber-reinforced composite in flexural testing.

    PubMed

    Alander, Pasi; Lassila, Lippo V J; Tezvergil, Arzu; Vallittu, Pekka K

    2004-05-01

    The aim of this study was to examine the emission of acoustic signals from six commercially available fiber-reinforced composites (FRC) used in the frameworks of fixed partial dentures in material bending. FRC test specimens were made of six commercially available fiber products of polyethylene or glass and five light-curing resins. FRC test specimens were polymerized with a hand light-curing unit or with a light-curing oven. The flexural test for determination of ultimate flexural strength of test specimens (n = 6) was based on the ISO 10477 standard after the specimens were stored in air or in water for two weeks. The acoustic emission (AE) signals were monitored during three-point loading test of the test specimens using a test with increasing loading levels until the specimens fractured. Generally, stress level required for the AE activity initiation ranged from 107 MPa (Ribbond) to 579 MPa (everStick). The ultimate flexural strength of FRC specimens were higher, ranging from 132 to 764 MPa, being highest with everStick and Vectris FRC, and lowest with Ribbond FRC. ANOVA showed a statistically significant difference between the initiation of AE activity and the ultimate flexural strength according to the brand (p < 0.001) storing conditions (p < 0.001) and polymerization procedure (p < 0.001). AE activity and ultimate flexural strength correlated significantly (p < 0.010, r = 0.887). The result of this study suggested that AE activity in FRC specimens started at a 19-32% lower stress level than occurred at final fracture.

  8. Qualification testing of general electric 50 Ah nickel-cadmium cells with new separator and new positive plate processing

    NASA Astrophysics Data System (ADS)

    Morrow, G. W.

    1986-09-01

    Forty-two 50 Ah aerospace nickel-cadmium cells were delivered to Goddard Space Flight Center (GSFC) by General Electric (GE) in February, 1985, for the purpose of evaluating and qualifying a new nylon separator material Pellon 2536, and the new GE Positive Plate Nickel Attack Control Passivation process. Testing began in May, 1985, at the Naval Weapons Support Center (NWSC) in Crane, Indiana with standard initial evaluation tests. Life cycling in both Low Earth Orbit (LEO) and Geosynchronous Orbit (GEO) began in July, 1985, with approximately 1200 LEO cycles complete at this writting. Early test results show that cells with positive plate passivation exhibit higher than normal charge voltage characteristics. Other aspects of performance were nominal.

  9. Qualification Testing of General Electric 50 Ah Nickel-Cadmium Cells with New Separator and New Positive Plate Processing

    NASA Technical Reports Server (NTRS)

    Morrow, G. W.

    1986-01-01

    Forty-two 50 Ah aerospace nickel-cadmium cells were delivered to Goddard Space Flight Center (GSFC) by General Electric (GE) in February, 1985, for the purpose of evaluating and qualifying a new nylon separator material Pellon 2536, and the new GE Positive Plate Nickel Attack Control Passivation process. Testing began in May, 1985, at the Naval Weapons Support Center (NWSC) in Crane, Indiana with standard initial evaluation tests. Life cycling in both Low Earth Orbit (LEO) and Geosynchronous Orbit (GEO) began in July, 1985, with approximately 1200 LEO cycles complete at this writting. Early test results show that cells with positive plate passivation exhibit higher than normal charge voltage characteristics. Other aspects of performance were nominal.

  10. Environmental Exposure Effects on Composite Materials for Commercial Aircraft

    NASA Technical Reports Server (NTRS)

    Hoffman, D. J.

    1981-01-01

    This period's activities were highlighted by continued long term and accelerated lab exposure testing, and by completion of all fabrication tasks on the optional material systems, AS1/3501-6 and Kevlar 49/F161-188. Initial baseline testing was performed on the two optional material systems. Long term exposure specimens were returned from three of the four ground rack sites and from two of the three aircraft locations. Test data from specimens returned from Dryden after 2 years exposure do not indicate continuing trends of strength reduction from the 1 year data. Test data from specimens returned from the Wellington, new Zealand ground rack and on Air New Zealand aircraft after 1 year exposure show strength changes fairly typical of other locations.

  11. An Initial Study of the Fundamentals of Ice Crystal Icing Physics in the NASA Propulsion Systems Laboratory

    NASA Technical Reports Server (NTRS)

    Struk, Peter; Bartkus, Tadas; Tsao, Jen-Ching; Bencic, Timothy; King, Michael; Ratvasky, Thomas; Van Zante, Judith

    2017-01-01

    This presentation shows results from an initial study of the fundamental physics of ice-crystal ice accretion using the NASA Propulsion Systems Lab (PSL). Ice accretion due to the ingestion of ice-crystals is being attributed to numerous jet-engine power-loss events. The NASA PSL is an altitude jet-engine test facility which has recently added a capability to inject ice particles into the flow. NASA is evaluating whether this facility, in addition to full-engine and motor-driven-rig tests, can be used for more fundamental ice-accretion studies that simulate the different mixed-phase icing conditions along the core flow passage of a turbo-fan engine compressor. The data from such fundamental accretion tests will be used to help develop and validate models of the accretion process. The present study utilized a NACA0012 airfoil. The mixed-phase conditions were generated by partially freezing the liquid-water droplets ejected from the spray bars. This presentation shows data regarding (1) the freeze out characteristics of the cloud, (2) changes in aerothermal conditions due to the presence of the cloud, and (3) the ice accretion characteristics observed on the airfoil model. The primary variable in this test was the PSL plenum humidity which was systematically varied for two duct-exit-plane velocities (85 and 135 ms) as well as two particle size clouds (15 and 50 m MVDi). The observed clouds ranged from fully glaciated to fully liquid, where the liquid clouds were at least partially supercooled. The air total temperature decreased at the test section when the cloud was activated due to evaporation. The ice accretions observed ranged from sharp arrow-like accretions, characteristic of ice-crystal erosion, to cases with double-horn shapes, characteristic of supercooled water accretions.

  12. The effect of 'running-in' on the tribology and surface morphology of metal-on-metal Birmingham hip resurfacing device in simulator studies.

    PubMed

    Vassiliou, K; Elfick, A P D; Scholes, S C; Unsworth, A

    2006-02-01

    It is well documented that hard bearing combinations show a running-in phenomenon in vitro and there is also some evidence of this from retrieval studies. In order to investigate this phenomenon, five Birmingham hip resurfacing devices were tested in a hip wear simulator. One of these (joint 1) was also tested in a friction simulator before, during, and after the wear test and surface analysis was conducted throughout portions of the testing. The wear showed the classical running in with the wear rate falling from 1.84 mm3 per 10(6) cycles for the first 10(6) cycles of testing to 0.24 mm3 per 10(6) cycles over the final 2 x 10(6) cycles of testing. The friction tests suggested boundary lubrication initially, but at 1 x 10(6) cycles a mixed lubrication regime was evident. By 2 x 10(6) cycles the classical Stribeck curve had formed, indicating a considerable contribution from the fluid film at higher viscosities. This continued to be evident at both 3 x 10(6) and 5 x 10(6) cycles. The surface study complements these findings.

  13. Study for fabrication, evaluation, and testing of monolayer woven type materials for space suit insulation

    NASA Technical Reports Server (NTRS)

    Merrick, E. B.

    1979-01-01

    An alternative space suit insulation concept using a monolayer woven pile material is discussed. The material reduces cost and improves the durability of the overgarment, while providing protection similar to that provided by multilayer insulation (MLI). Twelve samples of different configurations were fabricated and tested for compressibility and thermal conductivity as a function of compression loading. Two samples which showed good results in the initial tests were further tested for thermal conductivity with respect to ambient pressure and temperature. Results of these tests were similar to results of the MLI tests, indicating the potential of the monolayer fabric to replace the present MLI. A seaming study illustrated that the fabric can be sewn in a structurally sound seam with minimal heat loss. It is recommended that a prototype thermal meteroid garment be fabricated.

  14. Experimental test of an online ion-optics optimizer

    NASA Astrophysics Data System (ADS)

    Amthor, A. M.; Schillaci, Z. M.; Morrissey, D. J.; Portillo, M.; Schwarz, S.; Steiner, M.; Sumithrarachchi, Ch.

    2018-07-01

    A technique has been developed and tested to automatically adjust multiple electrostatic or magnetic multipoles on an ion optical beam line - according to a defined optimization algorithm - until an optimal tune is found. This approach simplifies the process of determining high-performance optical tunes, satisfying a given set of optical properties, for an ion optical system. The optimization approach is based on the particle swarm method and is entirely model independent, thus the success of the optimization does not depend on the accuracy of an extant ion optical model of the system to be optimized. Initial test runs of a first order optimization of a low-energy (<60 keV) all-electrostatic beamline at the NSCL show reliable convergence of nine quadrupole degrees of freedom to well-performing tunes within a reasonable number of trial solutions, roughly 500, with full beam optimization run times of roughly two hours. Improved tunes were found both for quasi-local optimizations and for quasi-global optimizations, indicating a good ability of the optimizer to find a solution with or without a well defined set of initial multipole settings.

  15. Fracture Toughness of Z3CN20.09M Cast Stainless Steel with Long-Term Thermal Aging

    NASA Astrophysics Data System (ADS)

    Yu, Weiwei; Yu, Dunji; Gao, Hongbo; Xue, Fei; Chen, Xu

    2017-09-01

    Accelerated thermal aging tests were performed at 400 °C for nearly 18,000 h on Z3CN20.09M cast stainless steel which was used for primary coolant pipes of nuclear power plants. A series of Charpy impact tests were conducted on Z3CN20.09M after different long-term thermal aging time. The test results indicated that the Charpy impact energy of Z3CN20.09M cast stainless steel decreased rapidly at an early stage and then almost saturated after thermal aging of 10,000 h. Furthermore, J-resistance curves were measured for CT specimens of longitudinal and circumferential pipe orientations. It showed that there was no obvious difference in the fracture characteristics of Z3CN20.09M in different sampling directions. In addition, the observed stretch zone width (SZW) revealed that the value of initiation fracture toughness J SZW was significantly lower than that of fracture toughness J IC, indicating a low actual crack initiation energy due to long-term thermal aging.

  16. International Energy Agency Ocean Energy Systems Task 10 Wave Energy Converter Modeling Verification and Validation: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wendt, Fabian F; Yu, Yi-Hsiang; Nielsen, Kim

    This is the first joint reference paper for the Ocean Energy Systems (OES) Task 10 Wave Energy Converter modeling verification and validation group. The group is established under the OES Energy Technology Network program under the International Energy Agency. OES was founded in 2001 and Task 10 was proposed by Bob Thresher (National Renewable Energy Laboratory) in 2015 and approved by the OES Executive Committee EXCO in 2016. The kickoff workshop took place in September 2016, wherein the initial baseline task was defined. Experience from similar offshore wind validation/verification projects (OC3-OC5 conducted within the International Energy Agency Wind Task 30)more » [1], [2] showed that a simple test case would help the initial cooperation to present results in a comparable way. A heaving sphere was chosen as the first test case. The team of project participants simulated different numerical experiments, such as heave decay tests and regular and irregular wave cases. The simulation results are presented and discussed in this paper.« less

  17. [Early form of toxoplasmosis with accompanying enlargement of lymph nodes].

    PubMed

    Małafiej, Eugeniusz; Spiewak, Ewa; Frankowska, Joanna; Maciejewska, Ewa

    2004-05-01

    The paper describes a case of a 42-year-old female presented rapidly increasing enlargement of lymph nodes. Initially it was believed to be an effect of proliferous systemic changes. The diagnostic procedures did not confirm the initial diagnosis but they evoked a lot of stress of the patient as well as her psychic discomfort resulting from a number of biopsies. Serological tests carried out in the further course of the diagnostic procedure showed that the increased nodular reaction should be attributed to Toxoplasma gondii invasion, which was indicated by the presence of IgM and IgA antibodies and low avidity of IgG. The early administration of specific treatment with spiramycin led to the regression of the clinical symptoms and gradual normalization of the serological test. The case is worth attention for several reasons: 1. it indicates that it is necessary to consider T. gondii infection in basic clinical practice, which is frequently ignored, 2. it illustrates the effectiveness of early specific treatment, 3. it demonstrates the importance of well selected and properly interpreted microbiological tests.

  18. Corvids Outperform Pigeons and Primates in Learning a Basic Concept.

    PubMed

    Wright, Anthony A; Magnotti, John F; Katz, Jeffrey S; Leonard, Kevin; Vernouillet, Alizée; Kelly, Debbie M

    2017-04-01

    Corvids (birds of the family Corvidae) display intelligent behavior previously ascribed only to primates, but such feats are not directly comparable across species. To make direct species comparisons, we used a same/different task in the laboratory to assess abstract-concept learning in black-billed magpies ( Pica hudsonia). Concept learning was tested with novel pictures after training. Concept learning improved with training-set size, and test accuracy eventually matched training accuracy-full concept learning-with a 128-picture set; this magpie performance was equivalent to that of Clark's nutcrackers (a species of corvid) and monkeys (rhesus, capuchin) and better than that of pigeons. Even with an initial 8-item picture set, both corvid species showed partial concept learning, outperforming both monkeys and pigeons. Similar corvid performance refutes the hypothesis that nutcrackers' prolific cache-location memory accounts for their superior concept learning, because magpies rely less on caching. That corvids with "primitive" neural architectures evolved to equal primates in full concept learning and even to outperform them on the initial 8-item picture test is a testament to the shared (convergent) survival importance of abstract-concept learning.

  19. Presumed latent ocular tuberculosis diagnosed with the positive quantiFERON-TB Gold In-Tube Test in a HLA-A29-positive patient.

    PubMed

    Rangel, Carlos Mario; Atencia, Cesar; Merayo-Lloves, Jesus; Fernandez-Vega Sanz, Alvaro

    2015-06-04

    A 59-year-old Hispanic woman presented with a 3-year history of floaters associated with bilateral reduced visual acuity. Her best-corrected visual acuity (BCVA) was 20/40. Both anterior segments were without inflammation, but fundoscopy showed mild vitreous inflammation and multiple inflammatory choroidal lesions. Tests for inflammatory and infectious diseases were negative except for human leucocyte antigen A29. The patient was diagnosed with birdshot choroidoretinopathy, and treatment was initiated with cyclosporine A 2.5 mg/kg/day. One year after treatment, the patient reported systemic symptoms with no improvement in visual acuity. Fundus findings remained with vitreal inflammation. QuantiFERON-TB Gold In-Tube Test was positive, and a diagnosis of presumed latent ocular tuberculosis (TB) was made. We initiated anti-TB treatment for 9 months. At 6 months of anti-TB therapy, there was no active inflammation. The patient was followed for 2 years with no medications and no active inflammation. Her final BCVA was 20/25. 2015 BMJ Publishing Group Ltd.

  20. Comparison of detonation spreading in pressed ultra-fine and nano-TATB

    NASA Astrophysics Data System (ADS)

    Olles, Joseph; Wixom, Ryan; Knepper, Robert; Yarrington, Cole; Patel, Rajen; Stepanov, Victor

    2017-06-01

    Detonation spreading behavior in insensitive high explosives is an important performance characteristic for initiation-train design. In the past, several variations of the floret test have been used to study this phenomenon. Commonly, dent blocks or multi-fiber optical probes were employed for reduced cost and complexity. We devised a floret-like test, using minimal explosive material, to study the detonation spreading in nano-TATB as compared to ultra-fine TATB. Our test uses a streak camera, combined with photonic Doppler velocimetry, to image the breakout timing and quantify the output particle velocity. The TATB acceptor pellets are initiated using an explosively-driven aluminum flyer with a well characterized velocity. We characterized the two types of TATB by assessing purity, particle morphology, and the microstructure of the consolidated pellets. Our results align with published data for ultra-fine TATB, however the nano-TATB shows a distinct difference where output has a strong dependence on density. The results indicate that control over pellet pore size and pressing density may be used to optimize detonation spreading behavior.

Top