Sample records for injection method based

  1. Financial methods for waterflooding injectate design

    DOEpatents

    Heneman, Helmuth J.; Brady, Patrick V.

    2017-08-08

    A method of selecting an injectate for recovering liquid hydrocarbons from a reservoir includes designing a plurality of injectates, calculating a net present value of each injectate, and selecting a candidate injectate based on the net present value. For example, the candidate injectate may be selected to maximize the net present value of a waterflooding operation.

  2. Acupuncture injection for field amplified sample stacking and glass microchip-based capillary gel electrophoresis.

    PubMed

    Ha, Ji Won; Hahn, Jong Hoon

    2017-02-01

    Acupuncture sample injection is a simple method to deliver well-defined nanoliter-scale sample plugs in PDMS microfluidic channels. This acupuncture injection method in microchip CE has several advantages, including minimization of sample consumption, the capability of serial injections of different sample solutions into the same microchannel, and the capability of injecting sample plugs into any desired position of a microchannel. Herein, we demonstrate that the simple and cost-effective acupuncture sample injection method can be used for PDMS microchip-based field amplified sample stacking in the most simplified straight channel by applying a single potential. We achieved the increase in electropherogram signals for the case of sample stacking. Furthermore, we present that microchip CGE of ΦX174 DNA-HaeⅢ digest can be performed with the acupuncture injection method on a glass microchip while minimizing sample loss and voltage control hardware. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Study of the method of water-injected meat identifying based on low-field nuclear magnetic resonance

    NASA Astrophysics Data System (ADS)

    Xu, Jianmei; Lin, Qing; Yang, Fang; Zheng, Zheng; Ai, Zhujun

    2018-01-01

    The aim of this study to apply low-field nuclear magnetic resonance technique was to study regular variation of the transverse relaxation spectral parameters of water-injected meat with the proportion of water injection. Based on this, the method of one-way ANOVA and discriminant analysis was used to analyse the differences between these parameters in the capacity of distinguishing water-injected proportion, and established a model for identifying water-injected meat. The results show that, except for T 21b, T 22e and T 23b, the other parameters of the T 2 relaxation spectrum changed regularly with the change of water-injected proportion. The ability of different parameters to distinguish water-injected proportion was different. Based on S, P 22 and T 23m as the prediction variable, the Fisher model and the Bayes model were established by discriminant analysis method, qualitative and quantitative classification of water-injected meat can be realized. The rate of correct discrimination of distinguished validation and cross validation were 88%, the model was stable.

  4. Intelligent methods for the process parameter determination of plastic injection molding

    NASA Astrophysics Data System (ADS)

    Gao, Huang; Zhang, Yun; Zhou, Xundao; Li, Dequn

    2018-03-01

    Injection molding is one of the most widely used material processing methods in producing plastic products with complex geometries and high precision. The determination of process parameters is important in obtaining qualified products and maintaining product quality. This article reviews the recent studies and developments of the intelligent methods applied in the process parameter determination of injection molding. These intelligent methods are classified into three categories: Case-based reasoning methods, expert system- based methods, and data fitting and optimization methods. A framework of process parameter determination is proposed after comprehensive discussions. Finally, the conclusions and future research topics are discussed.

  5. Waterflooding injectate design systems and methods

    DOEpatents

    Brady, Patrick V.; Krumhansl, James L.

    2016-12-13

    A method of recovering a liquid hydrocarbon using an injectate includes recovering the liquid hydrocarbon through primary extraction. Physico-chemical data representative of electrostatic interactions between the liquid hydrocarbon and the reservoir rock are measured. At least one additive of the injectate is selected based on the physico-chemical data. The method includes recovering the liquid hydrocarbon from the reservoir rock through secondary extraction using the injectate.

  6. Investigation of micro-injection molding based on longitudinal ultrasonic vibration core.

    PubMed

    Qiu, Zhongjun; Yang, Xue; Zheng, Hui; Gao, Shan; Fang, Fengzhou

    2015-10-01

    An ultrasound-assisted micro-injection molding method is proposed to improve the rheological behavior of the polymer melt radically, and a micro-injection molding system based on a longitudinal ultrasonic vibration core is developed and employed in the micro-injection molding process of Fresnel lenses. The verification experiments show that the filling mold area of the polymer melt is increased by 6.08% to 19.12%, and the symmetric deviation of the Fresnel lens is improved 15.62% on average. This method improved the filling performance and replication quality of the polymer melt in the injection molding process effectively.

  7. Fundamentals of rapid injection molding for microfluidic cell-based assays.

    PubMed

    Lee, Ulri N; Su, Xiaojing; Guckenberger, David J; Dostie, Ashley M; Zhang, Tianzi; Berthier, Erwin; Theberge, Ashleigh B

    2018-01-30

    Microscale cell-based assays have demonstrated unique capabilities in reproducing important cellular behaviors for diagnostics and basic biological research. As these assays move beyond the prototyping stage and into biological and clinical research environments, there is a need to produce microscale culture platforms more rapidly, cost-effectively, and reproducibly. 'Rapid' injection molding is poised to meet this need as it enables some of the benefits of traditional high volume injection molding at a fraction of the cost. However, rapid injection molding has limitations due to the material and methods used for mold fabrication. Here, we characterize advantages and limitations of rapid injection molding for microfluidic device fabrication through measurement of key features for cell culture applications including channel geometry, feature consistency, floor thickness, and surface polishing. We demonstrate phase contrast and fluorescence imaging of cells grown in rapid injection molded devices and provide design recommendations to successfully utilize rapid injection molding methods for microscale cell-based assay development in academic laboratory settings.

  8. Optimisation of warpage on plastic injection moulding part using response surface methodology (RSM) and genetic algorithm method (GA)

    NASA Astrophysics Data System (ADS)

    Miza, A. T. N. A.; Shayfull, Z.; Nasir, S. M.; Fathullah, M.; Hazwan, M. H. M.

    2017-09-01

    In this study, Computer Aided Engineering was used for injection moulding simulation. The method of Design of experiment (DOE) was utilize according to the Latin Square orthogonal array. The relationship between the injection moulding parameters and warpage were identify based on the experimental data that used. Response Surface Methodology (RSM) was used as to validate the model accuracy. Then, the RSM and GA method were combine as to examine the optimum injection moulding process parameter. Therefore the optimisation of injection moulding is largely improve and the result shown an increasing accuracy and also reliability. The propose method by combining RSM and GA method also contribute in minimising the warpage from occur.

  9. Determination of tannin in green tea infusion by flow-injection analysis based on quenching the fluorescence of 3-aminophthalate.

    PubMed

    Chen, Richie L C; Lin, Chun-Hsun; Chung, Chien-Yu; Cheng, Tzong-Jih

    2005-11-02

    A flow-injection analytical system was developed to determine tannin content in green tea infusions. The flow-injection system is based on measuring the quenching effect of tannin on the fluorescence of 3-aminophthalate. Fluorophore was obtained by auto-oxidation of luminol during solution preparation. System performance was satisfactory for routine analysis (sample throughput >20 h(-1); linear dynamic range for tannic acid, 0.005-0.3 mg/mL; linear dynamic range for green tea tannin, 0.02-1.0 mg/mL; CV < 3%). The flow-injection method is immune from interference by coexisting ascorbate in green tea infusion. Analytical results were verified by the ferrous tartrate method, the Japanese official analytical method.

  10. Efficient flow injection and sequential injection methods for spectrophotometric determination of oxybenzone in sunscreens based on reaction with Ni(II).

    PubMed

    Chisvert, A; Salvador, A; Pascual-Martí, M C; March, J G

    2001-04-01

    Spectrophotometric determination of a widely used UV-filter, such as oxybenzone, is proposed. The method is based on the complexation reaction between oxybenzone and Ni(II) in ammoniacal medium. The stoichiometry of the reaction, established by the Job method, was 1:1. Reaction conditions were studied and the experimental parameters were optimized, for both flow injection (FI) and sequential injection (SI) determinations, with comparative purposes. Sunscreen formulations containing oxybenzone were analyzed by the proposed methods and results compared with those obtained by HPLC. Data show that both FI and SI procedures provide accurate and precise results. The ruggedness, sensitivity and LOD are adequate to the analysis requirements. The sample frequency obtained by FI is three-fold higher than that of SI analysis. SI is less reagent-consuming than FI.

  11. Investigating the weight ratio variation of alginate-hydroxyapatite composites for vertebroplasty method bone filler material

    NASA Astrophysics Data System (ADS)

    Lestari, Gusti Ruri; Yuwono, Akhmad Herman; Sofyan, Nofrijon; Ramahdita, Ghiska

    2017-02-01

    One of the newly developed methods for curing spinal fracture due to osteoporosis is vertebroplasty. The method is basically based on injection of special material directly to the fractured spine in order to commence the formation of new bone. Therefore, appropriate injectable materials are very important to the curing success. In this study, injectable alginate-hydroxyapatite (HA) composites were fabricated varying the weight percentage of alginate upon synthesis procedure. The result of injection capability and compressive tests as well as Fourier transform infrared (FTIR) spectroscopy and scanning electron microscope (SEM) suggested that bone filler composite containing 60 wt% alginate is the optimum composition obtaining a compressive modulus up to 0.15 MPa, injection capability of more than 85% and morphology with uniform porous and fibrous structure. This injectable composite fabrication process can be used for the development of injectable materials system for vertebroplasty method.

  12. The evaluation of the optimization design and application effect of same-well-injection-production technique’s injection-production circulatory system

    NASA Astrophysics Data System (ADS)

    Guoxing, Zheng; Minghu, Jiang; Hongliang, Gong; Nannan, Zhang; Jianguang, Wei

    2018-02-01

    According to basic principles of combining series of strata and demands of same-well injection-production technique, the optimization designing method of same-well injection-production technique’s injection-production circulatory system is given. Based on oil-water two-phase model with condition of arbitrarily well network, a dynamic forecast method for the application of same-well injection-production reservoir is established with considering the demands and capacity of same-well injection-production technique, sample wells are selected to launch the forecast evaluation and analysis of same-well injection-production reservoir application’s effect. Results show: single-test-well composite water cut decreases by 4.7% and test-well-group composite water cut decreases by 1.56% under the condition of basically invariant ground water injection rate. The method provides theoretical support for the proof of same-well injection-production technique’s reservoir development improving effect and further tests.

  13. Meeting Rural Demand: A Case for Combining Community-Based Distribution and Social Marketing of Injectable Contraceptives in Tigray, Ethiopia

    PubMed Central

    Prata, Ndola; Weidert, Karen; Fraser, Ashley; Gessessew, Amanuel

    2013-01-01

    Background In Sub-Saharan Africa, policy changes have begun to pave the way for community distribution of injectable contraceptives but sustaining such efforts remains challenging. Combining social marketing with community-based distribution provides an opportunity to recover some program costs and compensate workers with proceeds from contraceptive sales. This paper proposes a model for increasing access to injectable contraceptives in rural settings by using community-based distributers as social marketing agents and incorporating financing systems to improve sustainability. Methods This intervention was implemented in three districts of the Central Zone of Tigray, Ethiopia and program data has been collected from November 2011 through October 2012. A total of 137 Community Based Reproductive Health Agents (CBRHAs) were trained to provide injectable contraceptives and were provided with a loan of 25 injectable contraceptives from a drug revolving fund, created with project funds. The price of a single dose credited to a CBRHA was 3 birr ($0.17) and they provide injections to women for 5 birr ($0.29), determined with willingness-to-pay data. Social marketing was used to create awareness and generate demand. Both quantitative and qualitative methods were used to examine important feasibility aspects of the intervention. Results Forty-four percent of CBRHAs were providing family planning methods at the time of the training and 96% believed providing injectable contraceptives would improve their services. By October 2012, 137 CBRHAs had successfully completed training and provided 2541 injections. Of total injections, 47% were provided to new users of injectable contraceptives. Approximately 31% of injections were given for free to the poorest women, including adolescents. Conclusions Insights gained from the first year of implementation of the model provide a framework for further expansion in Tigray, Ethiopia. Our experience highlights how program planners can tailor interventions to match family planning preferences and create more sustainable contraceptive service provision with greater impact. PMID:23874767

  14. Rapid and Automated Analytical Methods for Redox Species Based on Potentiometric Flow Injection Analysis Using Potential Buffers

    PubMed Central

    Ohura, Hiroki; Imato, Toshihiko

    2011-01-01

    Two analytical methods, which prove the utility of a potentiometric flow injection technique for determining various redox species, based on the use of some redox potential buffers, are reviewed. The first is a potentiometric flow injection method in which a redox couple such as Fe(III)-Fe(II), Fe(CN)6 3−-Fe(CN)(CN)6 4−, and bromide-bromine and a redox electrode or a combined platinum-bromide ion selective electrode are used. The analytical principle and advantages of the method are discussed, and several examples of its application are reported. Another example is a highly sensitive potentiometric flow injection method, in which a large transient potential change due to bromine or chlorine as an intermediate, generated during the reaction of the oxidative species with an Fe(III)-Fe(II) potential buffer containing bromide or chloride, is utilized. The analytical principle and details of the proposed method are described, and examples of several applications are described. The determination of trace amounts of hydrazine, based on the detection of a transient change in potential caused by the reaction with a Ce(IV)-Ce(III) potential buffer, is also described. PMID:21584280

  15. Spin-injection into epitaxial graphene on silicon carbide

    NASA Astrophysics Data System (ADS)

    Konishi, Keita; Cui, Zhixin; Hiraki, Takahiro; Yoh, Kanji

    2013-09-01

    We have studied the spin-injection properties in epitaxial graphene on SiC. The ferromagnetic metal (FM) electrodes were composed of a tunnel barrier layer AlOx (14 Å) and a ferromagnetic Co (600 Å) layer. We have successfully observed the clear resistance peaks indicating spin-injection both in the "local" and "non-local" spin measurement set-ups at low temperatures. We estimate spin-injection rate of 1% based on "non-local" measurement and 1.6% based on local measurements. Spin-injection rate of multilayer graphene by mechanical exfoliation method was twice as high as single layer graphene on SiC based on "local" measurement.

  16. Diagnostics and Identification of Injection Duration of Common Rail Diesel Injectors

    NASA Astrophysics Data System (ADS)

    Krogerus, Tomi R.; Huhtala, Kalevi J.

    2018-02-01

    In this paper, we study the diagnostics and identification of injection duration of common rail (CR) diesel pilot injectors of dual-fuel engines. In these pilot injectors, the injected volume is small and the repeatability of the injections and identification of the drifts of the injectors are important factors, which need to be taken into account in achieving good repeatability (shot-to-shot with every cylinder) and therefore a well-balanced engine and reduced overall wear. A diagnostics method based on analysis of CR pressure signal with experimental verification results is presented. Using the developed method, the relative duration of injection events can be identified. In the method, the pressure signal during the injection is first extracted after the control of each injection event. After that, the signal is normalized and filtered. Then a derivative of the filtered signal is calculated. Change in the derivative of the filtered signal larger than a predefined threshold indicates an injection event which can be detected and its relative duration can be identified. The efficacy of the proposed diagnostics method is presented with the experimental results, which show that the developed method detects drifts in injection duration and the magnitude of drift. According to the result, ≥ 10 μs change (2%, 500 μs) in injection time can be identified.

  17. Methods and Variables Associated with the Risk of Septic Arthritis Following Intra-Articular Injections in Horses: A Survey of Veterinarians.

    PubMed

    Gillespie, Caroline C; Adams, Stephen B; Moore, George E

    2016-11-01

    To determine common methods for intra-articular injections and variables associated with the risk of septic arthritis following intra-articular injection in the horse. Cross-sectional survey. Equine veterinarians. A link to an online survey was distributed to equine practitioners in 2014. Responses for descriptive data were tabulated. Data on infection rates obtained from medical records were analyzed. Variables associated with the risk of septic arthritis were determined using χ 2 or Fisher's exact tests and logistic regression. Common current methods for intra-articular injections were determined from 241 surveys. Sixty-four of 241 surveys (26.6%) contained data with numbers of joints injected and number of infections obtained from review of medical records. Eight different injection methods were used by more than 2/3 of responding veterinarians. A total of 67 out of 319,760 injected joints reported became septic following injection, giving an incidence of 2.10 septic joints per 10,000 intra-articular injections. Based on multivariate analysis, infection rates were significantly lower when veterinarians prepared their own injection sites (OR=0.10) and had <20 years of practice experience (OR=0.025), whereas infection rates were significantly higher when hair was removed at the injection site (OR=19.70). There is a low incidence of septic arthritis following intra-articular injection and a large number of injection methods reported by responding veterinarians. The low reported incidence of infection may be related to the large number of practitioners frequently using common methods. © Copyright 2016 by The American College of Veterinary Surgeons.

  18. Activity and Residues of Imidacloprid Applied to Soil and Tree Trunks to Control Hemlock Woolly Adelgid (Hemiptera: Adelgidae) in Forests

    Treesearch

    R.S. Cowles; M.E. Montgomery; C.A.S.-J. Cheah

    2006-01-01

    We studied imidacloprid application methods and timing to control the hemlock woolly adelgid, Adelges tsugae Annand (Hemiptera: Adelgidae), in forests. The methods compared were 1) soil injection near the trunk; 2) soil injection dispersed throughout the area under the canopy; 3) soil drench near the base of the trunk; and trunk injection with the 4...

  19. Methods of Si based ceramic components volatilization control in a gas turbine engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garcia-Crespo, Andres Jose; Delvaux, John; Dion Ouellet, Noemie

    A method of controlling volatilization of silicon based components in a gas turbine engine includes measuring, estimating and/or predicting a variable related to operation of the gas turbine engine; correlating the variable to determine an amount of silicon to control volatilization of the silicon based components in the gas turbine engine; and injecting silicon into the gas turbine engine to control volatilization of the silicon based components. A gas turbine with a compressor, combustion system, turbine section and silicon injection system may be controlled by a controller that implements the control method.

  20. Numerical study of rotating detonation engine with an array of injection holes

    NASA Astrophysics Data System (ADS)

    Yao, S.; Han, X.; Liu, Y.; Wang, J.

    2017-05-01

    This paper aims to adopt the method of injection via an array of holes in three-dimensional numerical simulations of a rotating detonation engine (RDE). The calculation is based on the Euler equations coupled with a one-step Arrhenius chemistry model. A pre-mixed stoichiometric hydrogen-air mixture is used. The present study uses a more practical fuel injection method in RDE simulations, injection via an array of holes, which is different from the previous conventional simulations where a relatively simple full injection method is usually adopted. The computational results capture some important experimental observations and a transient period after initiation. These phenomena are usually absent in conventional RDE simulations due to the use of an idealistic injection approximation. The results are compared with those obtained from other numerical studies and experiments with RDEs.

  1. A novel fault location scheme for power distribution system based on injection method and transient line voltage

    NASA Astrophysics Data System (ADS)

    Huang, Yuehua; Li, Xiaomin; Cheng, Jiangzhou; Nie, Deyu; Wang, Zhuoyuan

    2018-02-01

    This paper presents a novel fault location method by injecting travelling wave current. The new methodology is based on Time Difference Of Arrival(TDOA)measurement which is available measurements the injection point and the end node of main radial. In other words, TDOA is the maximum correlation time when the signal reflected wave crest of the injected and fault appear simultaneously. Then distance calculation is equal to the wave velocity multiplied by TDOA. Furthermore, in case of some transformers connected to the end of the feeder, it’s necessary to combine with the transient voltage comparison of amplitude. Finally, in order to verify the effectiveness of this method, several simulations have been undertaken by using MATLAB/SIMULINK software packages. The proposed fault location is useful to short the positioning time in the premise of ensuring the accuracy, besides the error is 5.1% and 13.7%.

  2. Hydrodynamics based transfection in normal and fibrotic rats

    PubMed Central

    Yeikilis, Rita; Gal, Shunit; Kopeiko, Natalia; Paizi, Melia; Pines, Mark; Braet, Filip; Spira, Gadi

    2006-01-01

    AIM: Hydrodynamics based transfection (HBT), the injection of a large volume of naked plasmid DNA in a short time is a relatively simple, efficient and safe method for in vivo transfection of liver cells. Though used for quite some time, the mechanism of gene transfection has not yet been elucidated. METHODS: A luciferase encoding plasmid was injected using the hydrodynamics based procedure into normal and thioacetamide-induced fibrotic Sprague Dawley rats. Scanning and transmission electron microscopy images were taken. The consequence of a dual injection of Ringer solution and luciferase pDNA was followed. Halofuginone, an anti collagen type I inhibitor was used to reduce ECM load in fibrotic rats prior to the hydrodynamic injection. RESULTS: Large endothelial gaps formed as soon as 10’ following hydrodynamic injection; these gradually returned to normal 10 d post injection. Hydrodynamic administration of Ringer 10 or 30 m prior to moderate injection of plasmid did not result in efficient transfection suggesting that endothelial gaps by themselves are not sufficient for gene expression. Gene transfection following hydrodynamic injection in thioacetamide induced fibrotic rats was diminished coinciding with the level of fibrosis. Halofuginone, a specific collagen typeIinhibitor, alleviated this effect. CONCLUSION: The hydrodynamic pressure formed following HBT results in the formation of large endothelial gaps. These gaps, though important in the transfer of DNA molecules from the blood to the space of Disse are not enough to provide the appropriate conditions for hepatocyte transfection. Hydrodynamics based injection is applicable in fibrotic rats provided that ECM load is reduced. PMID:17036386

  3. Rapid quantitative detection of glucose content in glucose injection by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2017-10-20

    This work investigates an automated technique for rapid detecting the glucose content in glucose injection by reaction headspace gas chromatography (HS-GC). This method is based on the oxidation reaction of glucose in glucose injection with potassium dichromate. The carbon dioxide (CO 2 ) formed from the oxidation reaction can be quantitatively detected by GC. The results show that the relative standard deviation (RSD) of the present method was within 2.91%, and the measured glucose contents in glucose injection closely match those quantified by the reference method (relative differences <6.45%). The new HS-GC technique is rapid, practical and can be used to the batch detection of the glucose content in glucose injection related applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Flow injection method for sulphide determination using an organic mercury compound

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yaqoob, M.; Anwar, M.; Masood, A.S.

    1991-04-01

    A simple flow injection analysis method is described for the determination of soluble sulfide, based on the complexation of sulfide with p-hydroxymercurbenzoic acid, in the presence of dithizone used as an indicator. The reaction is very rapid, with a sampling rate of 90/hr. and requires a very short length post injection reaction coil. The detection limit and precision are 0.01 mM and 0.7%, respectively.

  5. Retention of denture bases fabricated by three different processing techniques – An in vivo study

    PubMed Central

    Chalapathi Kumar, V. H.; Surapaneni, Hemchand; Ravikiran, V.; Chandra, B. Sarat; Balusu, Srilatha; Reddy, V. Naveen

    2016-01-01

    Aim: Distortion due to Polymerization shrinkage compromises the retention. To evaluate the amount of retention of denture bases fabricated by conventional, anchorized, and injection molding polymerization techniques. Materials and Methods: Ten completely edentulous patients were selected, impressions were made, and master cast obtained was duplicated to fabricate denture bases by three polymerization techniques. Loop was attached to the finished denture bases to estimate the force required to dislodge them by retention apparatus. Readings were subjected to nonparametric Friedman two-way analysis of variance followed by Bonferroni correction methods and Wilcoxon matched-pairs signed-ranks test. Results: Denture bases fabricated by injection molding (3740 g), anchorized techniques (2913 g) recorded greater retention values than conventional technique (2468 g). Significant difference was seen between these techniques. Conclusions: Denture bases obtained by injection molding polymerization technique exhibited maximum retention, followed by anchorized technique, and least retention was seen in conventional molding technique. PMID:27382542

  6. Experimental analysis of computer system dependability

    NASA Technical Reports Server (NTRS)

    Iyer, Ravishankar, K.; Tang, Dong

    1993-01-01

    This paper reviews an area which has evolved over the past 15 years: experimental analysis of computer system dependability. Methodologies and advances are discussed for three basic approaches used in the area: simulated fault injection, physical fault injection, and measurement-based analysis. The three approaches are suited, respectively, to dependability evaluation in the three phases of a system's life: design phase, prototype phase, and operational phase. Before the discussion of these phases, several statistical techniques used in the area are introduced. For each phase, a classification of research methods or study topics is outlined, followed by discussion of these methods or topics as well as representative studies. The statistical techniques introduced include the estimation of parameters and confidence intervals, probability distribution characterization, and several multivariate analysis methods. Importance sampling, a statistical technique used to accelerate Monte Carlo simulation, is also introduced. The discussion of simulated fault injection covers electrical-level, logic-level, and function-level fault injection methods as well as representative simulation environments such as FOCUS and DEPEND. The discussion of physical fault injection covers hardware, software, and radiation fault injection methods as well as several software and hybrid tools including FIAT, FERARI, HYBRID, and FINE. The discussion of measurement-based analysis covers measurement and data processing techniques, basic error characterization, dependency analysis, Markov reward modeling, software-dependability, and fault diagnosis. The discussion involves several important issues studies in the area, including fault models, fast simulation techniques, workload/failure dependency, correlated failures, and software fault tolerance.

  7. Meeting rural demand: a case for combining community-based distribution and social marketing of injectable contraceptives in Tigray, Ethiopia.

    PubMed

    Prata, Ndola; Weidert, Karen; Fraser, Ashley; Gessessew, Amanuel

    2013-01-01

    In Sub-Saharan Africa, policy changes have begun to pave the way for community distribution of injectable contraceptives but sustaining such efforts remains challenging. Combining social marketing with community-based distribution provides an opportunity to recover some program costs and compensate workers with proceeds from contraceptive sales. This paper proposes a model for increasing access to injectable contraceptives in rural settings by using community-based distributers as social marketing agents and incorporating financing systems to improve sustainability. This intervention was implemented in three districts of the Central Zone of Tigray, Ethiopia and program data has been collected from November 2011 through October 2012. A total of 137 Community Based Reproductive Health Agents (CBRHAs) were trained to provide injectable contraceptives and were provided with a loan of 25 injectable contraceptives from a drug revolving fund, created with project funds. The price of a single dose credited to a CBRHA was 3 birr ($0.17) and they provide injections to women for 5 birr ($0.29), determined with willingness-to-pay data. Social marketing was used to create awareness and generate demand. Both quantitative and qualitative methods were used to examine important feasibility aspects of the intervention. Forty-four percent of CBRHAs were providing family planning methods at the time of the training and 96% believed providing injectable contraceptives would improve their services. By October 2012, 137 CBRHAs had successfully completed training and provided 2541 injections. Of total injections, 47% were provided to new users of injectable contraceptives. Approximately 31% of injections were given for free to the poorest women, including adolescents. Insights gained from the first year of implementation of the model provide a framework for further expansion in Tigray, Ethiopia. Our experience highlights how program planners can tailor interventions to match family planning preferences and create more sustainable contraceptive service provision with greater impact.

  8. Large-scale preparation of clove essential oil and eugenol-loaded liposomes using a membrane contactor and a pilot plant.

    PubMed

    Sebaaly, Carine; Greige-Gerges, Hélène; Agusti, Géraldine; Fessi, Hatem; Charcosset, Catherine

    2016-01-01

    Based on our previous study where optimal conditions were defined to encapsulate clove essential oil (CEO) into liposomes at laboratory scale, we scaled-up the preparation of CEO and eugenol (Eug)-loaded liposomes using a membrane contactor (600 mL) and a pilot plant (3 L) based on the principle of ethanol injection method, both equipped with a Shirasu Porous Glass membrane for injection of the organic phase into the aqueous phase. Homogenous, stable, nanometric-sized and multilamellar liposomes with high phospholipid, Eug loading rates and encapsulation efficiency of CEO components were obtained. Saturation of phospholipids and drug concentration in the organic phase may control the liposome stability. Liposomes loaded with other hydrophobic volatile compounds could be prepared at large scale using the ethanol injection method and a membrane for injection.

  9. [Analysis of clinical use of Danhong injection based on hospital information system].

    PubMed

    Chen, Qian; Yi, Danhui; Xie, Yanming; Yang, Wei; Yang, Wei; Zhuang, Yan; Du, Jing

    2011-10-01

    To know how Danhong injection is used in clinical practice and to provide a reference for guiding clinical use of Danhong Injection. Extract Danhong injection's post-marketing re-evaluation data from the Hospital Information System of ten three grade III-A General Hospitals in Beijing, use basic statistical analysis methods to analyze Danhong injection's indications, usage and dosage, days of treatment etc. in clinical practice. In patients using Danhong injection, there were more than 60 percent patients were prescribed based on main-diagnosis, first-visit and other diagnosis, which were also coincided with Danhong injection's instruction. In clinical practice, 95.5 percent of Danhong injection's administration routes conformed to the instruction and more than 90 percent of Danhong injection's dosage were within the limits prescribed by the instruction. Danhong injection was used less than 20 days successively. Danhong injection was used in combination with drugs with the action of removing blood stasis, antianginal drug, antiplatelet drug, drugs for cerebrovascular disease and so on. Danhong injection has been used according to instruction in practice almostly.

  10. Safe Injection Practices in Primary Health Care Settings of Naxalbari Block, Darjeeling District, West Bengal.

    PubMed

    Chaudhuri, Sudip Banik; Ray, Kuntala

    2016-01-01

    Unsafe injection can transmit many diseases to patients, injection providers and healthy people of community. To find out critical steps whether executed according to recommended best practice methods, availability of equipments in health facilities for safe injection practices and some important steps of waste disposal methods. This facility-based cross-sectional observational study was conducted among 30 Auxiliary nurse midwives (ANM) & 27 nursing staffs (NS) to assess certain aspects of their practice while administrating injection and disposal of the disposables. Health facilities were also observed to asses necessary equipments of safe injection and waste disposal methods. Among the health workers 93.3% ANM and 100% NS took sterile syringe from sterile unopened packet, all of the study subjects washed hand before giving injection, 13.3% of ANMs and 8% of NS are fully vaccinated against Hep B, 53.3% of ANM and all NS are practices non recapping. Only 13.33% sub centres along with PHC & BPHC had at least one puncture resistant leak proof container, 86.7% sub centres, PHC are free from loose needles. Transport for off side treatment is the method of waste disposal in case of 73.3% cases sub centres, PHC & BPHC. There is need to educate, train and motivate service providers in proper methods of giving injection along with improve the adequacy of supply of required equipments.

  11. Separating inverse spin Hall voltage and spin rectification voltage by inverting spin injection direction

    NASA Astrophysics Data System (ADS)

    Zhang, Wenxu; Peng, Bin; Han, Fangbin; Wang, Qiuru; Soh, Wee Tee; Ong, Chong Kim; Zhang, Wanli

    2016-03-01

    We develop a method for universally resolving the important issue of separating the inverse spin Hall effect (ISHE) from the spin rectification effect (SRE) signal. This method is based on the consideration that the two effects depend on the spin injection direction: The ISHE is an odd function of the spin injection direction while the SRE is independent on it. Thus, the inversion of the spin injection direction changes the ISHE voltage signal, while the SRE voltage remains. It applies generally to analyzing the different voltage contributions without fitting them to special line shapes. This fast and simple method can be used in a wide frequency range and has the flexibility of sample preparation.

  12. Waterflood control system for maximizing total oil recovery

    DOEpatents

    Patzek, Tadeusz Wiktor; Silin, Dimitriy Borisovic; De, Asoke Kumar

    2005-06-07

    A control system and method for determining optimal fluid injection pressure is based upon a model of a growing hydrofracture due to waterflood injection pressure. This model is used to develop a control system optimizing the injection pressure by using a prescribed injection goal coupled with the historical times, pressures, and volume of injected fluid at a single well. In this control method, the historical data is used to derive two major flow components: the transitional component, where cumulative injection volume is scaled as the square root of time, and a steady-state breakthrough component, which scales linearly with respect to time. These components provide diagnostic information and allow for the prevention of rapid fracture growth and associated massive water break through that is an important part of a successful waterflood, thereby extending the life of both injection and associated production wells in waterflood secondary oil recovery operations.

  13. Waterflood control system for maximizing total oil recovery

    DOEpatents

    Patzek, Tadeusz Wiktor [Oakland, CA; Silin, Dimitriy Borisovich [Pleasant Hill, CA; De, Asoke Kumar [San Jose, CA

    2007-07-24

    A control system and method for determining optimal fluid injection pressure is based upon a model of a growing hydrofracture due to waterflood injection pressure. This model is used to develop a control system optimizing the injection pressure by using a prescribed injection goal coupled with the historical times, pressures, and volume of injected fluid at a single well. In this control method, the historical data is used to derive two major flow components: the transitional component, where cumulative injection volume is scaled as the square root of time, and a steady-state breakthrough component, which scales linearly with respect to time. These components provide diagnostic information and allow for the prevention of rapid fracture growth and associated massive water break through that is an important part of a successful waterflood, thereby extending the life of both injection and associated production wells in waterflood secondary oil recovery operations.

  14. Detecting subsurface fluid leaks in real-time using injection and production rates

    NASA Astrophysics Data System (ADS)

    Singh, Harpreet; Huerta, Nicolas J.

    2017-12-01

    CO2 injection into geologic formations for either enhanced oil recovery or carbon storage introduces a risk for undesired fluid leakage into overlying groundwater or to the surface. Despite decades of subsurface CO2 production and injection, the technologies and methods for detecting CO2 leaks are still costly and prone to large uncertainties. This is especially true for pressure-based monitoring methods, which require the use of simplified geological and reservoir flow models to simulate the pressure behavior as well as background noise affecting pressure measurements. In this study, we propose a method to detect the time and volume of fluid leakage based on real-time measurements of well injection and production rates. The approach utilizes analogies between fluid flow and capacitance-resistance modeling. Unlike other leak detection methods (e.g. pressure-based), the proposed method does not require geological and reservoir flow models to simulate the behavior that often carry significant sources of uncertainty; therefore, with our approach the leak can be detected with greater certainty. The method can be applied to detect when a leak begins by tracking a departure in fluid production rate from the expected pattern. The method has been tuned to detect the effect of boundary conditions and fluid compressibility on leakage. To highlight the utility of this approach we use our method to detect leaks for two scenarios. The first scenario simulates a fluid leak from the storage formation into an above-zone monitoring interval. The second scenario simulates intra-reservoir migration between two compartments. We illustrate this method to detect fluid leakage in three different reservoirs with varying levels of geological and structural complexity. The proposed leakage detection method has three novelties: i) requires only readily-available data (injection and production rates), ii) accounts for fluid compressibility and boundary effects, and iii) in addition to detecting the time when a leak is activated and the volume of that leakage, this method provides an insight about the leak location, and reservoir connectivity. We are proposing this as a complementary method that can be used with other, more expensive, methods early on in the injection process. This will allow an operator to conduct more expensive surveys less often because the proposed method can show if there are no leaks on a monthly basis that is cheap and fast.

  15. A novel segmentation method for uneven lighting image with noise injection based on non-local spatial information and intuitionistic fuzzy entropy

    NASA Astrophysics Data System (ADS)

    Yu, Haiyan; Fan, Jiulun

    2017-12-01

    Local thresholding methods for uneven lighting image segmentation always have the limitations that they are very sensitive to noise injection and that the performance relies largely upon the choice of the initial window size. This paper proposes a novel algorithm for segmenting uneven lighting images with strong noise injection based on non-local spatial information and intuitionistic fuzzy theory. We regard an image as a gray wave in three-dimensional space, which is composed of many peaks and troughs, and these peaks and troughs can divide the image into many local sub-regions in different directions. Our algorithm computes the relative characteristic of each pixel located in the corresponding sub-region based on fuzzy membership function and uses it to replace its absolute characteristic (its gray level) to reduce the influence of uneven light on image segmentation. At the same time, the non-local adaptive spatial constraints of pixels are introduced to avoid noise interference with the search of local sub-regions and the computation of local characteristics. Moreover, edge information is also taken into account to avoid false peak and trough labeling. Finally, a global method based on intuitionistic fuzzy entropy is employed on the wave transformation image to obtain the segmented result. Experiments on several test images show that the proposed method has excellent capability of decreasing the influence of uneven illumination on images and noise injection and behaves more robustly than several classical global and local thresholding methods.

  16. Determination of dipyrone in pharmaceutical preparations based on the chemiluminescent reaction of the quinolinic hydrazide-H2O2-vanadium(IV) system and flow-injection analysis.

    PubMed

    Pradana Pérez, Juan A; Durand Alegría, Jesús S; Hernando, Pilar Fernández; Sierra, Adolfo Narros

    2012-01-01

    A rapid, economic and sensitive chemiluminescent method involving flow-injection analysis was developed for the determination of dipyrone in pharmaceutical preparations. The method is based on the chemiluminescent reaction between quinolinic hydrazide and hydrogen peroxide in a strongly alkaline medium, in which vanadium(IV) acts as a catalyst. Principal chemical and physical variables involved in the flow-injection system were optimized using a modified simplex method. The variations in the quantum yield observed when dipyrone was present in the reaction medium were used to determine the concentration of this compound. The proposed method requires no preconcentration steps and reliably quantifies dipyrone over the linear range 1-50 µg/mL. In addition, a sample throughput of 85 samples/h is possible. Copyright © 2011 John Wiley & Sons, Ltd.

  17. Analysis of selected antibiotics in surface freshwater and seawater using direct injection in liquid chromatography electrospray ionization tandem mass spectrometry.

    PubMed

    Bayen, Stéphane; Yi, Xinzhu; Segovia, Elvagris; Zhou, Zhi; Kelly, Barry C

    2014-04-18

    Emerging contaminants such as antibiotics have received recent attention as they have been detected in natural waters and health concerns over potential antibiotic resistance. With the purpose to investigate fast and high-throughput analysis, and eventually the continuous on-line analysis of emerging contaminants, this study presents results on the analysis of seven selected antibiotics (sulfadiazine, sulfamethazine, sulfamerazine, sulfamethoxazole, chloramphenicol, lincomycin, tylosin) in surface freshwater and seawater using direct injection of a small sample volume (20μL) in liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Notably, direct injection of seawater in the LC-ESI-MS/MS was made possible on account of the post-column switch on the system, which allows diversion of salt-containing solutions flushed out of the column to the waste. Mean recoveries based on the isotope dilution method average 95±14% and 96±28% amongst the compounds for spiked freshwater and seawater, respectively. Linearity across six spiking levels was assessed and the response was linear (r(2)>0.99) for all compounds. Direct injection concentrations were compared for real samples to those obtained with the conventional SPE-based analysis and both techniques concurs on the presence/absence and levels of the compounds in real samples. These results suggest direct injection is a reliable method to detect antibiotics in both freshwater and seawater. Method detection limits for the direct injection technique (37pg/L to 226ng/L in freshwater, and from 16pg/to 26ng/L in seawater) are sufficient for a number of environmental applications, for example the fast screening of water samples for ecological risk assessments. In the present study of real samples, this new method allowed for example the positive detection of some compounds (e.g. lincomycin) down to the sub ng/L range. The direct injection method appears to be relatively cheaper and faster, requires a smaller sample size, and is more robust to equipment cross-contamination as compared to the conventional SPE-based method. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Best infection control practices for intradermal, subcutaneous, and intramuscular needle injections.

    PubMed Central

    Hutin, Yvan; Hauri, Anja; Chiarello, Linda; Catlin, Mary; Stilwell, Barbara; Ghebrehiwet, Tesfamicael; Garner, Julia

    2003-01-01

    OBJECTIVE: To draw up evidence-based guidelines to make injections safer. METHODS: A development group summarized evidence-based best practices for preventing injection-associated infections in resource-limited settings. The development process included a breakdown of the WHO reference definition of a safe injection into a list of potentially critical steps, a review of the literature for each of these steps, the formulation of best practices, and the submission of the draft document to peer review. FINDINGS: Eliminating unnecessary injections is the highest priority in preventing injection-associated infections. However, when intradermal, subcutaneous, or intramuscular injections are medically indicated, best infection control practices include the use of sterile injection equipment, the prevention of contamination of injection equipment and medication, the prevention of needle-stick injuries to the provider, and the prevention of access to used needles. CONCLUSION: The availability of best infection control practices for intradermal, subcutaneous, and intramuscular injections will provide a reference for global efforts to achieve the goal of safe and appropriate use of injections. WHO will revise the best practices five years after initial development, i.e. in 2005. PMID:12973641

  19. Replication fidelity improvement of PMMA microlens array based on weight evaluation and optimization

    NASA Astrophysics Data System (ADS)

    Jiang, Bing-yan; Shen, Long-jiang; Peng, Hua-jiang; Yin, Xiang-lin

    2007-12-01

    High replication fidelity is a prerequisite of high quality plastic microlens array in injection molding. But, there's not an economical and practical method to evaluate and improve the replication fidelity until now. Based on part weight evaluation and optimization, this paper presents a new method of replication fidelity improvement. Firstly, a simplified analysis model of PMMA micro columns arrays (5×16) with 200μm diameter was set up. And then, Flow (3D) module of Moldflow MPI6.0 based on Navier-Stokes equations was used to calculate the weight of the micro columns arrays in injection molding. The effects of processing parameters (melt temperature, mold temperature, injection time, packing pressure and packing time) on the part weight were investigated in the simulations. The simulation results showed that the mold temperature and the injection time have important effects on the filling of micro columns; the optimal mold temperature and injection time for better replication fidelity could be determined by the curves of mold temperature vs part weight and injection time vs part weight. At last, the effects of processing parameters on part weight of micro columns array were studied experimentally. The experimental results showed that the increase of melt temperature and mold temperature can make the packing pressure transfer to micro cavity more effectively through runner system, and increase the part weight. From the observation results of the image measuring apparatus, it was discovered that the higher the part weight, the better the filling of the microstructures. In conclusion, part weight can be used to evaluate the replication fidelity of micro-feature structured parts primarily; which is an economical and practical method to improve the replication fidelity of microlens arrays based on weight evaluation and optimization.

  20. Dimensional Precision Research of Wax Molding Rapid Prototyping based on Droplet Injection

    NASA Astrophysics Data System (ADS)

    Mingji, Huang; Geng, Wu; yan, Shan

    2017-11-01

    The traditional casting process is complex, the mold is essential products, mold quality directly affect the quality of the product. With the method of rapid prototyping 3D printing to produce mold prototype. The utility wax model has the advantages of high speed, low cost and complex structure. Using the orthogonal experiment as the main method, analysis each factors of size precision. The purpose is to obtain the optimal process parameters, to improve the dimensional accuracy of production based on droplet injection molding.

  1. Enabling skin vaccination using new delivery technologies

    PubMed Central

    Kim, Yeu-Chun; Prausnitz, Mark R.

    2011-01-01

    The skin is known to be a highly immunogenic site for vaccination, but few vaccines in clinical use target skin largely because conventional intradermal injection is difficult and unreliable to perform. Now, a number of new or newly adapted delivery technologies have been shown to administer vaccine to the skin either by non-invasive or minimally invasive methods. Non-invasive methods include high-velocity powder and liquid jet injection, as well as diffusion-based patches in combination with skin abrasion, thermal ablation, ultrasound, electroporation, and chemical enhancers. Minimally invasive methods are generally based on small needles, including solid microneedle patches, hollow microneedle injections, and tattoo guns. The introduction of these advanced delivery technologies can make the skin a site for simple, reliable vaccination that increases vaccine immunogenicity and offers logistical advantages to improve the speed and coverage of vaccination. PMID:21799951

  2. Enabling skin vaccination using new delivery technologies

    PubMed Central

    Kim, Yeu-Chun; Prausnitz, Mark R.

    2011-01-01

    The skin is known to be a highly immunogenic site for vaccination, but few vaccines in clinical use target skin largely because conventional intradermal injection is difficult and unreliable to perform. Now, a number of new or newly adapted delivery technologies have been shown to administer vaccine to the skin either by non-invasive or minimally invasive methods. Non-invasive methods include high-velocity powder and liquid jet injection, as well as diffusion-based patches in combination with skin abrasion, thermal ablation, ultrasound, electroporation, and chemical enhancers. Minimally invasive methods are generally based on small needles, including solid microneedle patches, hollow microneedle injections and tattoo guns. The introduction of these advanced delivery technologies can make the skin a site for simple, reliable vaccination that increases vaccine immunogenicity and offers logistical advantages to improve the speed and coverage of vaccination. PMID:21472533

  3. Linear Elastic and Cohesive Fracture Analysis to Model Hydraulic Fracture in Brittle and Ductile Rocks

    NASA Astrophysics Data System (ADS)

    Yao, Yao

    2012-05-01

    Hydraulic fracturing technology is being widely used within the oil and gas industry for both waste injection and unconventional gas production wells. It is essential to predict the behavior of hydraulic fractures accurately based on understanding the fundamental mechanism(s). The prevailing approach for hydraulic fracture modeling continues to rely on computational methods based on Linear Elastic Fracture Mechanics (LEFM). Generally, these methods give reasonable predictions for hard rock hydraulic fracture processes, but still have inherent limitations, especially when fluid injection is performed in soft rock/sand or other non-conventional formations. These methods typically give very conservative predictions on fracture geometry and inaccurate estimation of required fracture pressure. One of the reasons the LEFM-based methods fail to give accurate predictions for these materials is that the fracture process zone ahead of the crack tip and softening effect should not be neglected in ductile rock fracture analysis. A 3D pore pressure cohesive zone model has been developed and applied to predict hydraulic fracturing under fluid injection. The cohesive zone method is a numerical tool developed to model crack initiation and growth in quasi-brittle materials considering the material softening effect. The pore pressure cohesive zone model has been applied to investigate the hydraulic fracture with different rock properties. The hydraulic fracture predictions of a three-layer water injection case have been compared using the pore pressure cohesive zone model with revised parameters, LEFM-based pseudo 3D model, a Perkins-Kern-Nordgren (PKN) model, and an analytical solution. Based on the size of the fracture process zone and its effect on crack extension in ductile rock, the fundamental mechanical difference of LEFM and cohesive fracture mechanics-based methods is discussed. An effective fracture toughness method has been proposed to consider the fracture process zone effect on the ductile rock fracture.

  4. The impact of injector-based contrast agent administration in time-resolved MRA.

    PubMed

    Budjan, Johannes; Attenberger, Ulrike I; Schoenberg, Stefan O; Pietsch, Hubertus; Jost, Gregor

    2018-05-01

    Time-resolved contrast-enhanced MR angiography (4D-MRA), which allows the simultaneous visualization of the vasculature and blood-flow dynamics, is widely used in clinical routine. In this study, the impact of two different contrast agent injection methods on 4D-MRA was examined in a controlled, standardized setting in an animal model. Six anesthetized Goettingen minipigs underwent two identical 4D-MRA examinations at 1.5 T in a single session. The contrast agent (0.1 mmol/kg body weight gadobutrol, followed by 20 ml saline) was injected using either manual injection or an automated injection system. A quantitative comparison of vascular signal enhancement and quantitative renal perfusion analyses were performed. Analysis of signal enhancement revealed higher peak enhancements and shorter time to peak intervals for the automated injection. Significantly different bolus shapes were found: automated injection resulted in a compact first-pass bolus shape clearly separated from the recirculation while manual injection resulted in a disrupted first-pass bolus with two peaks. In the quantitative perfusion analyses, statistically significant differences in plasma flow values were found between the injection methods. The results of both qualitative and quantitative 4D-MRA depend on the contrast agent injection method, with automated injection providing more defined bolus shapes and more standardized examination protocols. • Automated and manual contrast agent injection result in different bolus shapes in 4D-MRA. • Manual injection results in an undefined and interrupted bolus with two peaks. • Automated injection provides more defined bolus shapes. • Automated injection can lead to more standardized examination protocols.

  5. THE DEVELOPMENT OF IODINE BASED IMPINGER SOLUTIONS FOR THE EFFICIENT CAPTURE OF HG USING DIRECT INJECTION NEBULIZATION - INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY ANALYSIS

    EPA Science Inventory

    Inductively coupled plasma mass spectrometry (ICP/MS) with direct injection nebulization (DIN) was used to evaluate novel impinger solution compositions capable of capturing elemental mercury (Hgo) in EPA Method 5 type sampling. An iodine based impinger solutoin proved to be ver...

  6. Comparison of Fit of Dentures Fabricated by Traditional Techniques Versus CAD/CAM Technology.

    PubMed

    McLaughlin, J Bryan; Ramos, Van; Dickinson, Douglas P

    2017-11-14

    To compare the shrinkage of denture bases fabricated by three methods: CAD/CAM, compression molding, and injection molding. The effect of arch form and palate depth was also tested. Nine titanium casts, representing combinations of tapered, ovoid, and square arch forms and shallow, medium, and deep palate depths, were fabricated using electron beam melting (EBM) technology. For each base fabrication method, three poly(vinyl siloxane) impressions were made from each cast, 27 dentures for each method. Compression-molded dentures were fabricated using Lucitone 199 poly methyl methacrylate (PMMA), and injection molded dentures with Ivobase's Hybrid Pink PMMA. For CAD/CAM, denture bases were designed and milled by Avadent using their Light PMMA. To quantify the space between the denture and the master cast, silicone duplicating material was placed in the intaglio of the dentures, the titanium master cast was seated under pressure, and the silicone was then trimmed and recovered. Three silicone measurements per denture were recorded, for a total of 243 measurements. Each silicone measurement was weighed and adjusted to the surface area of the respective arch, giving an average and standard deviation for each denture. Comparison of manufacturing methods showed a statistically significant difference (p = 0.0001). Using a ratio of the means, compression molding had on average 41% to 47% more space than injection molding and CAD/CAM. Comparison of arch/palate forms showed a statistically significant difference (p = 0.023), with shallow palate forms having more space with compression molding. The ovoid shallow form showed CAD/CAM and compression molding had more space than injection molding. Overall, injection molding and CAD/CAM fabrication methods produced equally well-fitting dentures, with both having a better fit than compression molding. Shallow palates appear to be more affected by shrinkage than medium or deep palates. Shallow ovoid arch forms appear to benefit from the use of injection molding compared to CAD/CAM and compression molding. © 2017 by the American College of Prosthodontists.

  7. Vibration anesthesia for the reduction of pain with facial dermal filler injections.

    PubMed

    Mally, Pooja; Czyz, Craig N; Chan, Norman J; Wulc, Allan E

    2014-04-01

    Vibration anesthesia is an effective pain-reduction technique for facial cosmetic injections. The analgesic effect of this method was tested in this study during facial dermal filler injections. The study aimed to evaluate the safety and efficacy of vibration anesthesia for these facial injections. This prospective study analyzed 41 patients who received dermal filler injections to the nasolabial folds, tear troughs, cheeks, and other facial sites. The injections were administered in a randomly assigned split-face design. One side of the patient's face received vibration together with dermal filler injections, whereas the other side received dermal filler injections alone. The patients completed a posttreatment questionnaire pertaining to injection pain, adverse effects, and preference for vibration with future dermal filler injections. The patients experienced both clinically and statistically significant pain reduction when a vibration stimulus was co-administered with the dermal filler injections. No adverse events were reported. The majority of the patients (95 %) reported a preference for vibration anesthesia with subsequent dermal filler injections. Vibration is a safe and effective method of achieving anesthesia during facial dermal filler injections. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  8. A dilute-and-shoot flow-injection tandem mass spectrometry method for quantification of phenobarbital in urine.

    PubMed

    Alagandula, Ravali; Zhou, Xiang; Guo, Baochuan

    2017-01-15

    Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the gold standard of urine drug testing. However, current LC-based methods are time consuming, limiting the throughput of MS-based testing and increasing the cost. This is particularly problematic for quantification of drugs such as phenobarbital, which is often analyzed in a separate run because they must be negatively ionized. This study examined the feasibility of using a dilute-and-shoot flow-injection method without LC separation to quantify drugs with phenobarbital as a model system. Briefly, a urine sample containing phenobarbital was first diluted by 10 times, followed by flow injection of the diluted sample to mass spectrometer. Quantification and detection of phenobarbital were achieved by an electrospray negative ionization MS/MS system operated in the multiple reaction monitoring (MRM) mode with the stable-isotope-labeled drug as internal standard. The dilute-and-shoot flow-injection method developed was linear with a dynamic range of 50-2000 ng/mL of phenobarbital and correlation coefficient > 0.9996. The coefficients of variation and relative errors for intra- and inter-assays at four quality control (QC) levels (50, 125, 445 and 1600 ng/mL) were 3.0% and 5.0%, respectively. The total run time to quantify one sample was 2 min, and the sensitivity and specificity of the method did not deteriorate even after 1200 consecutive injections. Our method can accurately and robustly quantify phenobarbital in urine without LC separation. Because of its 2 min run time, the method can process 720 samples per day. This feasibility study shows that the dilute-and-shoot flow-injection method can be a general way for fast analysis of drugs in urine. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Explosive boiling of liquid nitrogen

    NASA Astrophysics Data System (ADS)

    Nakoryakov, V. E.; Tsoy, A. N.; Mezentsev, I. V.; Meleshkin, A. V.

    2014-12-01

    The present paper deals with experimental investigation of processes that occur when injecting a cryogenic fluid into water. The optical recording of the process of injection of a jet of liquid nitrogen into water has revealed the structure and the stages of this process. The results obtained can be used when studying a new method for producing gas hydrates based on the shock-wave method.

  10. Determination of ambroxol hydrochloride, methylparaben and benzoic acid in pharmaceutical preparations based on sequential injection technique coupled with monolithic column.

    PubMed

    Satínský, Dalibor; Huclová, Jitka; Ferreira, Raquel L C; Montenegro, Maria Conceição B S M; Solich, Petr

    2006-02-13

    The porous monolithic columns show high performance at relatively low pressure. The coupling of short monoliths with sequential injection technique (SIA) results in a new approach to implementation of separation step to non-separation low-pressure method. In this contribution, a new separation method for simultaneous determination of ambroxol, methylparaben and benzoic acid was developed based on a novel reversed-phase sequential injection chromatography (SIC) technique with UV detection. A Chromolith SpeedROD RP-18e, 50-4.6 mm column with 10 mm precolumn and a FIAlab 3000 system with a six-port selection valve and 5 ml syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-tetrahydrofuran-0.05M acetic acid (10:10:90, v/v/v), pH 3.75 adjusted with triethylamine, flow rate 0.48 mlmin(-1), UV-detection was at 245 nm. The analysis time was <11 min. A new SIC method was validated and compared with HPLC. The method was found to be useful for the routine analysis of the active compounds ambroxol and preservatives (methylparaben or benzoic acid) in various pharmaceutical syrups and drops.

  11. A rapid and accurate method for determining protein content in dairy products based on asynchronous-injection alternating merging zone flow-injection spectrophotometry.

    PubMed

    Liang, Qin-Qin; Li, Yong-Sheng

    2013-12-01

    An accurate and rapid method and a system to determine protein content using asynchronous-injection alternating merging zone flow-injection spectrophotometry based on reaction between coomassie brilliant blue G250 (CBBG) and protein was established. Main merit of our approach is that it can avoid interferences of other nitric-compounds in samples, such as melamine and urea. Optimized conditions are as follows: Concentrations of CBBG, polyvinyl alcohol (PVA), NaCl and HCl are 150 mg/l, 30 mg/l, 0.1 mol/l and 1.0% (v/v), respectively; volumes of the sample and reagent are 150 μl and 30 μl, respectively; length of a reaction coil is 200 cm; total flow rate is 2.65 ml/min. The linear range of the method is 0.5-15 mg/l (BSA), its detection limit is 0.05 mg/l, relative standard deviation is less than 1.87% (n=11), and analytical speed is 60 samples per hour. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Triggering processes of microseismic events associated with water injection in Okuaizu Geothermal Field, Japan

    NASA Astrophysics Data System (ADS)

    Okamoto, Kyosuke; Yi, Li; Asanuma, Hiroshi; Okabe, Takashi; Abe, Yasuyuki; Tsuzuki, Masatoshi

    2018-02-01

    A continuous water injection test was conducted to halt the reduction in steam production in the Okuaizu Geothermal Field, Japan. Understanding the factors triggering microseismicity associated with water injection is essential to ensuring effective steam production. We identified possible triggering processes by applying methods based on microseismic monitoring, including a new method to determine the presence of water in local fractures using scattered P-waves. We found that the evolving microseismicity near the injection point could be explained by a diffusion process and/or water migration. We also found that local microseismicity on a remote fault was likely activated by stress fluctuations resulting from changes in the injection rate. A mediator of this fluctuation might be water remaining in the fracture zone. After the injection was terminated, microseismicity possibly associated with the phase transition of the liquid was found. We conclude that a variety of triggering processes associated with water injection may exist.[Figure not available: see fulltext.

  13. Flow injection method for the determination of silver concentration in drinking water for spacecrafts.

    PubMed

    Bruzzoniti, Maria Concetta; Kobylinska, Dorota Korte; Franko, Mladen; Sarzanini, Corrado

    2010-04-14

    A flow injection method has been developed for determination of silver. The method is based on a reduction reaction with sodium borohydride which leads to the formation of a colloidal species which is monitored at a wavelength of 390 nm. The reaction variables flow rate, sodium borohydride concentration and pH, which affect sensitivity, were investigated and their effects were established using a two-levels, three-factor experimental design. Further optimization of manifold variables (reaction coil and injection volume) allowed us to determine silver in the range 0.050-5.0 mg L(-1) with a minimum detectable concentration of 0.050 mg L(-1). Silver is added, as biocide, to drinking water for spacecrafts. The chemical species of silver, present in this kind of sample, were characterized by a procedure based on the selective retention of Ag(+) onto a 2.2.2. cryptand based substrate followed by determination of the non-bound and bound (after elution) Ag(+) by the FIA method. The method optimized was applied to a drinking water sample provided for the launch with the Automated Transfer Vehicle (ATV) module Jule Verne to the International Space Station (March 9, 2008). Copyright 2010 Elsevier B.V. All rights reserved.

  14. Controlling feeding behavior by chemical or gene-directed targeting in the brain: what's so spatial about our methods?

    PubMed Central

    Khan, Arshad M.

    2013-01-01

    Intracranial chemical injection (ICI) methods have been used to identify the locations in the brain where feeding behavior can be controlled acutely. Scientists conducting ICI studies often document their injection site locations, thereby leaving kernels of valuable location data for others to use to further characterize feeding control circuits. Unfortunately, this rich dataset has not yet been formally contextualized with other published neuroanatomical data. In particular, axonal tracing studies have delineated several neural circuits originating in the same areas where ICI injection feeding-control sites have been documented, but it remains unclear whether these circuits participate in feeding control. Comparing injection sites with other types of location data would require careful anatomical registration between the datasets. Here, a conceptual framework is presented for how such anatomical registration efforts can be performed. For example, by using a simple atlas alignment tool, a hypothalamic locus sensitive to the orexigenic effects of neuropeptide Y (NPY) can be aligned accurately with the locations of neurons labeled by anterograde tracers or those known to express NPY receptors or feeding-related peptides. This approach can also be applied to those intracranial “gene-directed” injection (IGI) methods (e.g., site-specific recombinase methods, RNA expression or interference, optogenetics, and pharmacosynthetics) that involve viral injections to targeted neuronal populations. Spatial alignment efforts can be accelerated if location data from ICI/IGI methods are mapped to stereotaxic brain atlases to allow powerful neuroinformatics tools to overlay different types of data in the same reference space. Atlas-based mapping will be critical for community-based sharing of location data for feeding control circuits, and will accelerate our understanding of structure-function relationships in the brain for mammalian models of obesity and metabolic disorders. PMID:24385950

  15. Waterflooding injectate design systems and methods

    DOEpatents

    Brady, Patrick V.; Krumhansl, James L.

    2014-08-19

    A method of designing an injectate to be used in a waterflooding operation is disclosed. One aspect includes specifying data representative of chemical characteristics of a liquid hydrocarbon, a connate, and a reservoir rock, of a subterranean reservoir. Charged species at an interface of the liquid hydrocarbon are determined based on the specified data by evaluating at least one chemical reaction. Charged species at an interface of the reservoir rock are determined based on the specified data by evaluating at least one chemical reaction. An extent of surface complexation between the charged species at the interfaces of the liquid hydrocarbon and the reservoir rock is determined by evaluating at least one surface complexation reaction. The injectate is designed and is operable to decrease the extent of surface complexation between the charged species at interfaces of the liquid hydrocarbon and the reservoir rock. Other methods, apparatus, and systems are disclosed.

  16. Accuracy of low-field magnetic resonance imaging versus radiography for guiding injection of equine distal interphalangeal joint collateral ligaments.

    PubMed

    Lamb, Megan M; Barrett, Jennifer G; White, Nathaniel A; Werre, Stephen R

    2014-01-01

    Desmopathy of the distal interphalangeal joint collateral ligament is a common cause of lameness in the horse and carries a variable prognosis for soundness. Intralesional treatment has been proposed for improving outcome; however, limited reports describe methods for injecting this ligament. The purpose of this study was to compare accuracy of low-field magnetic resonance imaging (MRI) vs. radiography for injecting the collateral ligament of the distal interphalangeal joint. Equine cadaver digit pairs (n = 10) were divided by random assignment to injection of the ligament by either technique. An observer unaware of injection technique determined injection success based on postinjection MRI and/or gross sections acquired from the proximal, middle, and distal portions of the ligament. McNemar's test was performed to determine statistical difference between injection techniques, the number of injection attempts, and injection of the medial or lateral collateral ligament. Magnetic resonance imaging guided injection was successful more frequently than radiographic-guided injection based on postinjection MRI (24 of 30 vs. 9 of 30; P = 0.0006) and gross sections (26 of 30 vs. 13 of 30; P = 0.0008). At each level of the ligament (proximal, middle, and distal), MRI-guided injection resulted in more successful injections than radiographic guidance. Statistical significance occurred at the proximal aspect of the collateral ligament based on postinjection MRI (P = 0.0143) and the middle portion of the ligament based on gross sections (P = 0.0253). Findings supported future testing of standing, low-field MRI as a technique for delivering intralesional regenerative therapy in live horses with desmopathy of these collateral ligaments. © 2013 American College of Veterinary Radiology.

  17. Normal and reverse flow injection–spectrophotometric determination of thiamine hydrochloride in pharmaceutical preparations using diazotized metoclopramide

    PubMed Central

    Al Abachi, Mouayed Q.; Hadi, Hind

    2012-01-01

    Simple and sensitive normal and reverse flow injection methods for spectrophotometric determination of thiamine hydrochloride (THC) at the microgram level were proposed and optimized. Both methods are based on the reaction between THC and diazotized metoclopramide in alkaline medium. Beer’s law was obeyed over the range of 10–300 and 2–90 μg/mL, the limits of detection were 2.118 and 0.839 μg/mL and the sampling rates were 80 and 95 injections per hour for normal and reverse flow injection methods respectively. The application of both methods to commercially available pharmaceuticals produced acceptable results. The flow system is suitable for application in quality control processes. PMID:29403765

  18. Determination of albumin in bronchoalveolar lavage fluid by flow-injection fluorometry using chromazurol S.

    PubMed

    Sato, Takaji; Saito, Yoshihiro; Chikuma, Masahiko; Saito, Yutaka; Nagai, Sonoko

    2008-03-01

    A highly sensitive flow injection fluorometry for the determination of albumin was developed and applied to the determination of albumin in human bronchoalveolar lavage fluids (BALF). This method is based on binding of chromazurol S (CAS) to albumin. The calibration curve was linear in the range of 5-200 microg/ml of albumin. A highly linear correlation (r=0.986) was observed between the albumin level in BALF samples (n=25) determined by the proposed method and by a conventional fluorometric method using CAS (CAS manual method). The IgG interference was lower in the CAS flow injection method than in the CAS manual method. The albumin level in BALF collected from healthy volunteers (n=10) was 58.5+/-13.1 microg/ml. The albumin levels in BALF samples obtained from patients with sarcoidosis and idiopathic pulmonary fibrosis were increased. This finding shows that the determination of albumin levels in BALF samples is useful for investigating lung diseases and that CAS flow injection method is promising in the determination of trace albumin in BALF samples, because it is sensitive and precise.

  19. Dynamic measurement of speed of sound in n-Heptane by ultrasonics during fuel injections.

    PubMed

    Minnetti, Elisa; Pandarese, Giuseppe; Evangelisti, Piersavio; Verdugo, Francisco Rodriguez; Ungaro, Carmine; Bastari, Alessandro; Paone, Nicola

    2017-11-01

    The paper presents a technique to measure the speed of sound in fuels based on pulse-echo ultrasound. The method is applied inside the test chamber of a Zeuch-type instrument used for indirect measurement of the injection rate (Mexus). The paper outlines the pulse-echo method, considering probe installation, ultrasound beam propagation inside the test chamber, typical signals obtained, as well as different processing algorithms. The method is validated in static conditions by comparing the experimental results to the NIST database both for water and n-Heptane. The ultrasonic system is synchronized to the injector so that time resolved samples of speed of sound can be successfully acquired during a series of injections. Results at different operating conditions in n-Heptane are shown. An uncertainty analysis supports the analysis of results and allows to validate the method. Experimental results show that the speed of sound variation during an injection event is less than 1%, so the Mexus model assumption to consider it constant during the injection is valid. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. FPGA-based multiprocessor system for injection molding control.

    PubMed

    Muñoz-Barron, Benigno; Morales-Velazquez, Luis; Romero-Troncoso, Rene J; Rodriguez-Donate, Carlos; Trejo-Hernandez, Miguel; Benitez-Rangel, Juan P; Osornio-Rios, Roque A

    2012-10-18

    The plastic industry is a very important manufacturing sector and injection molding is a widely used forming method in that industry. The contribution of this work is the development of a strategy to retrofit control of an injection molding machine based on an embedded system microprocessors sensor network on a field programmable gate array (FPGA) device. Six types of embedded processors are included in the system: a smart-sensor processor, a micro fuzzy logic controller, a programmable logic controller, a system manager, an IO processor and a communication processor. Temperature, pressure and position are controlled by the proposed system and experimentation results show its feasibility and robustness. As validation of the present work, a particular sample was successfully injected.

  1. Determination of Reaction Stoichiometries by Flow Injection Analysis.

    ERIC Educational Resources Information Center

    Rios, Angel; And Others

    1986-01-01

    Describes a method of flow injection analysis intended for calculation of complex-formation and redox reaction stoichiometries based on a closed-loop configuration. The technique is suitable for use in undergraduate laboratories. Information is provided for equipment, materials, procedures, and sample results. (JM)

  2. Use of Protein G Microcolumns in Chromatographic Immunoassays: A Comparison of Competitive Binding Formats

    PubMed Central

    Pfaunmiller, Erika L.; Anguizola, Jeanethe A.; Milanuk, Mitchell L.; Carter, NaTasha; Hage, David S.

    2016-01-01

    Affinity microcolumns containing protein G were used as general platforms for creating chromatographic-based competitive binding immunoassays. Human serum albumin (HSA) was used as a model target for this work and HSA tagged with a near infrared fluorescent dye was utilized as the label. The protein G microcolumns were evaluated for use in several assay formats, including both solution-based and column-based competitive binding immunoassays and simultaneous or sequential injection formats. All of these methods were characterized by using the same amounts of labeled HSA and anti-HSA antibodies per sample, as chosen for the analysis of a protein target in the low-to-mid ng/mL range. The results were used to compare these formats in terms of their response, precision, limits of detection, and analysis time. All these methods gave detection limits in the range of 8–19 ng/mL and precisions ranging from ± 5% to ± 10% when using an injection flow rate of 0.10 mL/min. The column-based sequential injection immunoassay provided the best limit of detection and the greatest change in response at low target concentrations, while the solution-based simultaneous injection method had the broadest linear and dynamic ranges. These results provided valuable guidelines that can be employed to develop and extend the use of protein G microcolumns and these competitive binding formats to other protein biomarkers or biological agents of clinical or pharmaceutical interest. PMID:26777776

  3. Individual and Network Interventions With Injection Drug Users in 5 Ukraine Cities

    PubMed Central

    Lehman, Wayne E. K.; Latkin, Carl A.; Dvoryak, Sergey; Brewster, John T.; Royer, Mark S.; Sinitsyna, Larisa

    2011-01-01

    Objectives. We evaluated the effects of an individual intervention versus a network intervention on HIV-related injection and sexual risk behaviors among street-recruited opiate injection drug users in 5 Ukraine cities. Methods. Between 2004 and 2006, 722 opiate injection drug users were recruited to participate in interventions that were either individually based or based on a social network model in which peer educators intervened with their network members. Audio computer-assisted self-interview techniques were used to interview participants at baseline and follow-up. Results. Multiple logistic analyses controlling for baseline injection and sexual risks revealed that both peer educators and network members in the network intervention reduced injection-related risk behaviors significantly more than did those in the individually based intervention and that peer educators increased condom use significantly more than did those in the individual intervention. Individual intervention participants, however, showed significantly greater improvements than did network members with respect to reductions in sexual risk behaviors. Conclusions. Social network interventions may be more effective than individually based interventions in changing injection risk behaviors among both peer educators and network members. The effectiveness of network interventions in changing sexual risk behaviors is less clear, probably owing to network composition and inhibitions regarding discussing sexual risk behaviors. PMID:20395584

  4. Analysis of the possibilities and limits of the Moldflow method

    NASA Astrophysics Data System (ADS)

    Brierre, M.

    1982-01-01

    The Moldflow information and computation service is presented. Moldflow is a computer program and data bank available as a computer aid to dimensioning thermoplastic injection molding equipment and processes. It is based on the simultaneous solution of thermal and rheological equations and is intended to completely simulate the injection process. The Moldflow system is described and algorithms are discussed, based on Moldflow listings.

  5. Tetrakis(1-imidazolyl) borate (BIM4) based zwitterionic and related molecules used as electron injection layers

    DOEpatents

    Li, Huaping; Xu, Yunhua; Bazan, Guillermo C

    2013-02-05

    Tetrakis(1-imidazolyl)borate (BIm4) based zwitterionic and/or related molecules for the fabrication of PLEDs is provided. Device performances with these materials approaches that of devices with Ba/Al cathodes for which the cathode contact is ohmic. Methods of producing such materials, and electron injection layers and devices containing these materials are also provided.

  6. Complete denture base assessments using holograms: dimensional alterations after different activation methods

    NASA Astrophysics Data System (ADS)

    Dughir, Ciprian; Popovschi, Ana Maria; Cojocariu, Andreea Codruta; Topala, Florin Ionel; Negrutiu, Meda Lavinia; Sinescu, Cosmin; de Sabata, Aldo; Duma, Virgil-Florin

    2016-03-01

    Holography is a well-developed method with a large range of applications, including dentistry. This study uses holographic methods for the study of total dental prosthesis. The issue is that the transformation of wax denture base in polymethylacrylate causes dimensional alterations and retractions in the final dental constructs. These could cause the failure of the stability of the complete denture in the oral cavity. Thus, the aim of this study is to determine and to compare using holography, total prosthesis obtained using three different manufacturing methods: pressing, injection, and polymerization. Each of the three types of dentures thus produced were recorded over the previously wax complete base holographic plates. The dimensional alterations that appear after using the different activation methods were thus determined. The most significant modification was remarked in the custom press technology, while the smallest variations were detected in the injection alternative.

  7. Comparison of field-enhanced and pressure-assisted field-enhanced sample injection techniques for the analysis of water-soluble vitamins using CZE.

    PubMed

    Liu, Qingqing; Liu, Yaling; Guan, Yu; Jia, Li

    2009-04-01

    A new online concentration method, namely pressure-assisted field-enhanced sample injection (PA-FESI), was developed and compared with FESI for the analysis of water-soluble vitamins by CZE with UV detection. In PA-FESI, negative voltage and positive pressure were simultaneously applied to initialize PA-FESI. PA-FESI uses the hydrodynamic flow generated by the positive pressure to counterbalance the reverse EOF in the capillary column during electrokinetic sample injection, which allowed a longer injection time than usual FESI mode without compromising the separation efficiency. Using the PA-FESI method, the LODs of the vitamins were at ng/mL level based on the S/N of 3 and the RSDs of migration time and peak area for each vitamin (1 microg/mL) were less than 5.1%. The developed method was applied to the analysis of water-soluble vitamins in corns.

  8. Real-time ultrasound image classification for spine anesthesia using local directional Hadamard features.

    PubMed

    Pesteie, Mehran; Abolmaesumi, Purang; Ashab, Hussam Al-Deen; Lessoway, Victoria A; Massey, Simon; Gunka, Vit; Rohling, Robert N

    2015-06-01

    Injection therapy is a commonly used solution for back pain management. This procedure typically involves percutaneous insertion of a needle between or around the vertebrae, to deliver anesthetics near nerve bundles. Most frequently, spinal injections are performed either blindly using palpation or under the guidance of fluoroscopy or computed tomography. Recently, due to the drawbacks of the ionizing radiation of such imaging modalities, there has been a growing interest in using ultrasound imaging as an alternative. However, the complex spinal anatomy with different wave-like structures, affected by speckle noise, makes the accurate identification of the appropriate injection plane difficult. The aim of this study was to propose an automated system that can identify the optimal plane for epidural steroid injections and facet joint injections. A multi-scale and multi-directional feature extraction system to provide automated identification of the appropriate plane is proposed. Local Hadamard coefficients are obtained using the sequency-ordered Hadamard transform at multiple scales. Directional features are extracted from local coefficients which correspond to different regions in the ultrasound images. An artificial neural network is trained based on the local directional Hadamard features for classification. The proposed method yields distinctive features for classification which successfully classified 1032 images out of 1090 for epidural steroid injection and 990 images out of 1052 for facet joint injection. In order to validate the proposed method, a leave-one-out cross-validation was performed. The average classification accuracy for leave-one-out validation was 94 % for epidural and 90 % for facet joint targets. Also, the feature extraction time for the proposed method was 20 ms for a native 2D ultrasound image. A real-time machine learning system based on the local directional Hadamard features extracted by the sequency-ordered Hadamard transform for detecting the laminae and facet joints in ultrasound images has been proposed. The system has the potential to assist the anesthesiologists in quickly finding the target plane for epidural steroid injections and facet joint injections.

  9. Modeling of cobalt-based catalyst use during CSS for low-temperature heavy oil upgrading

    NASA Astrophysics Data System (ADS)

    Kadyrov, R.; Sitnov, S.; Gareev, B.; Batalin, G.

    2018-05-01

    One of the methods, which is actively used on deposits of heavy oils of the Upper Kungurian (Ufimian) sandstones of the Republic of Tatarstan, is cyclic steam simulation (CSS). This method consists of 3 stages: injection, soaking, and production. Steam is injected into a well at a temperature of 300 to 340° C for a period of weeks to months. Then, the well is allowed to sit for days to weeks to allow heat to soak into the formation. Finally, the hot oil is pumped out of the well for a period of weeks or months. Once the production rate falls off, the well is put through another cycle. The injection of the catalyst solution before the injection of steam opens the possibility for upgrading the heavy oil in the process of aquathermolysis directly in the reservoir. In this paper, the possibility of using a catalyst precursor based on cobalt for upgrading the hydrocarbons of this field in the process of their extraction is represented. SARA analysis on oil saturated sandstones shows an increase in the proportion of saturated hydrocarbons by 11.1% due to the hydrogenation of aromatic hydrocarbons and their derivatives, the content of resins and asphaltenes are remained practically unchanged. A new method for estimating the adsorption of a catalyst based on taking into account the change in the concentration of the base metal before and after simulation of catalyst injection in the thermobaric conditions of the reservoir is proposed. During the study of catalyst adsorption in the rock, when simulating the CSS process, it is found that almost 28% of the cobalt, which is the main element of the catalyst precursor, is retained in the rock.

  10. On finding the analytic dependencies of the external field potential on the control function when optimizing the beam dynamics

    NASA Astrophysics Data System (ADS)

    Ovsyannikov, A. D.; Kozynchenko, S. A.; Kozynchenko, V. A.

    2017-12-01

    When developing a particle accelerator for generating the high-precision beams, the injection system design is of importance, because it largely determines the output characteristics of the beam. At the present paper we consider the injection systems consisting of electrodes with given potentials. The design of such systems requires carrying out simulation of beam dynamics in the electrostatic fields. For external field simulation we use the new approach, proposed by A.D. Ovsyannikov, which is based on analytical approximations, or finite difference method, taking into account the real geometry of the injection system. The software designed for solving the problems of beam dynamics simulation and optimization in the injection system for non-relativistic beams has been developed. Both beam dynamics and electric field simulations in the injection system which use analytical approach and finite difference method have been made and the results presented in this paper.

  11. Ultra-trace level determination of diquat and paraquat residues in surface and drinking water using ion-pair liquid chromatography with tandem mass spectrometry: a comparison of direct injection and solid-phase extraction methods.

    PubMed

    Oh, Jin-Aa; Lee, Jun-Bae; Lee, Soo-Hyung; Shin, Ho-Sang

    2014-10-01

    Direct injection and solid-phase extraction methods for the determination of diquat and paraquat in surface and drinking water were developed using liquid chromatography with tandem mass spectrometry. The signal intensities of analytes based on six ion-pairing reagents were compared with each other, and 12.5 mM nonafluoropentanoic acid was selected as the best suited amongst them. A clean-up method was developed using Oasis hydrophilic-lipophilic balance; this was compared to the direct injection method, with respect to limits of detection, interference, precision, and accuracy. Limits of quantification of diquat and paraquat were 0.03 and 0.01 μg/L using the direct injection method, and 0.002 and 0.001 μg/L using the hydrophilic-lipophilic balance method. When the hydrophilic-lipophilic balance method was used to analyze target compounds in 114 surface water and 30 drinking water samples, paraquat and diquat were detected within a concentration range of 0.001-0.12 and 0.002-0.038 μg/L in surface water, respectively. When the direct injection method was used to analyze target compounds in the same samples, the detected concentrations of paraquat and diquat were within 25% in samples being >0.015 μg/L using the hydrophilic-lipophilic balance method. The liquid chromatography with tandem mass spectrometry method using direct injection can thus be used for routine monitoring of paraquat and diquat in surface and drinking water. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. FPGA-Based Multiprocessor System for Injection Molding Control

    PubMed Central

    Muñoz-Barron, Benigno; Morales-Velazquez, Luis; Romero-Troncoso, Rene J.; Rodriguez-Donate, Carlos; Trejo-Hernandez, Miguel; Benitez-Rangel, Juan P.; Osornio-Rios, Roque A.

    2012-01-01

    The plastic industry is a very important manufacturing sector and injection molding is a widely used forming method in that industry. The contribution of this work is the development of a strategy to retrofit control of an injection molding machine based on an embedded system microprocessors sensor network on a field programmable gate array (FPGA) device. Six types of embedded processors are included in the system: a smart-sensor processor, a micro fuzzy logic controller, a programmable logic controller, a system manager, an IO processor and a communication processor. Temperature, pressure and position are controlled by the proposed system and experimentation results show its feasibility and robustness. As validation of the present work, a particular sample was successfully injected. PMID:23202036

  13. Design of a Coupled Thermoresponsive Hydrogel and Robotic System for Postinfarct Biomaterial Injection Therapy

    PubMed Central

    Fok, Kevin; Yoshizumi, Tomo; Park, Daewoo; Jiang, Hongbin; Schwartzman, David S.; Zenati, Marco A.; Uchibori, Takafumi

    2016-01-01

    Background In preclinical testing, ventricular wall injection of hydrogels has been shown to be effective in modulating ventricular remodeling and preserving cardiac function. For some approaches, early-stage clinical trials are under way. The hydrogel delivery method varies, with minimally invasive approaches being preferred. Endocardial injections carry a risk of hydrogel regurgitation into the circulation, and precise injection patterning is a challenge. An epicardial approach with a thermally gelling hydrogel through the subxiphoid pathway overcomes these disadvantages. Methods A relatively stiff, thermally responsive, injectable hydrogel based on N-isopropylacrylamide and N-vinylpyrrolidone (VP gel) was synthesized and characterized. VP gel thermal behavior was tuned to couple with a transepicardial injection robot, incorporating a cooling feature to achieve injectability. Ventricular wall injections of the optimized VP gel have been performed ex vivo and on beating porcine hearts. Results Thermal transition temperature, viscosity, and gelling time for the VP gel were manipulated by altering N-vinylpyrrolidone content. The target parameters for cooling in the robotic system were chosen by thermal modeling to support smooth, repeated injections on an ex vivo heart. Injections at predefined locations and depth were confirmed in an infarcted porcine model. Conclusions A coupled thermoresponsive hydrogel and robotic injection system incorporating a temperature-controlled injectate line was capable of targeted injections and amenable to use with a subxiphoid transepicardial approach for hydrogel injection after myocardial infarction. The confirmation of precise location and depth injections would facilitate a patient-specific planning strategy to optimize injection patterning to maximize the mechanical benefits of hydrogel placement. PMID:27154150

  14. Effectiveness of Shield Termination Techniques Tested with TEM Cell and Bulk Current Injection

    NASA Technical Reports Server (NTRS)

    Bradley, Arthur T.; Hare, Richard J.

    2009-01-01

    This paper presents experimental results of the effectiveness of various shield termination techniques. Each termination technique is evaluated by two independent noise injection methods; transverse electromagnetic (TEM) cell operated from 3 MHz 400 MHz, and bulk current injection (BCI) operated from 50 kHz 400 MHz. Both single carrier and broadband injection tests were investigated. Recommendations as to how to achieve the best shield transfer impedance (i.e. reduced coupled noise) are made based on the empirical data. Finally, the noise injection techniques themselves are indirectly evaluated by comparing the results obtained from the TEM Cell to those from BCI.

  15. Simultaneous injection-effective mixing analysis of palladium.

    PubMed

    Teshima, Norio; Noguchi, Daisuke; Joichi, Yasutaka; Lenghor, Narong; Ohno, Noriko; Sakai, Tadao; Motomizu, Shoji

    2010-01-01

    A novel concept of simultaneous injection-effective mixing analysis (SIEMA) is proposed, and a SIEMA method applied to the spectrophotometric determination of palladium using a water-soluble chromogenic reagent has been demonstrated. The flow configuration of SIEMA is a hybrid format of flow injection analysis (FIA), sequential injection analysis (SIA) and multicommutation in flow-based analysis. Sample and reagent solutions are aspirated into each holding coil through each solenoid valve by a syringe pump, and then the zones are simultaneously dispensed (injected) into a mixing coil by reversed flow toward a detector through a confluence point. This results in effective mixing and rapid detection with low reagent consumption.

  16. [Necessity of applying pharmacovigilance in post-marketing safety monitoring of traditional Chinese medicine injections].

    PubMed

    Wang, Hai-Nan; Chen, Wen; Fu, Zheng; Du, Wen-min; He, Jia

    2008-03-01

    Traditional Chinese medicine (TCM) injection has become one of the hotspots in the new TCM research and development. The serious adverse drug reactions happened in clinical have arosed attention widely in the whole society. It's very urgent to monitor the post-marketing safety of TCM injections. This paper elucidated the pharmacovigilance's necessity in the post-marketing safety monitoring of TCM injections, basing on the reason of safety problem of TCM injections and the future developing trend of adverse drug reaction monitoring. Also, this paper introduced the rapid signal detection method of spontaneous reporting system database by data mining technology.

  17. High-field neutral beam injection for improving the Q of a gas dynamic trap-based fusion neutron source

    NASA Astrophysics Data System (ADS)

    Zeng, Qiusun; Chen, Dehong; Wang, Minghuang

    2017-12-01

    In order to improve the fusion energy gain (Q) of a gas dynamic trap (GDT)-based fusion neutron source, a method in which the neutral beam is obliquely injected at a higher magnetic field position rather than at the mid-plane of the GDT is proposed. This method is beneficial for confining a higher density of fast ions at the turning point in the zone with a higher magnetic field, as well as obtaining a higher mirror ratio by reducing the mid-plane field rather than increasing the mirror field. In this situation, collision scattering loss of fast ions with higher density will occur and change the confinement time, power balance and particle balance. Using an updated calculation model with high-field neutral beam injection for a GDT-based fusion neutron source conceptual design, we got four optimal design schemes for a GDT-based fusion neutron source in which Q was improved to two- to three-fold compared with a conventional design scheme and considering the limitation for avoiding plasma instabilities, especially the fire-hose instability. The distribution of fast ions could be optimized by building a proper magnetic field configuration with enough space for neutron shielding and by multi-beam neutral particle injection at different axial points.

  18. Determination of Acidity Constants by Gradient Flow-Injection Titration

    ERIC Educational Resources Information Center

    Conceicao, Antonio C. L.; Minas da Piedade, Manuel E.

    2006-01-01

    A three-hour laboratory experiment, designed for an advanced undergraduate course in instrumental analysis that illustrates the application of the gradient chamber flow-injection titration (GCFIT) method with spectrophotometric detection to determine acidity constants is presented. The procedure involves the use of an acid-base indicator to obtain…

  19. Learning-Based Cell Injection Control for Precise Drop-on-Demand Cell Printing.

    PubMed

    Shi, Jia; Wu, Bin; Song, Bin; Song, Jinchun; Li, Shihao; Trau, Dieter; Lu, Wen F

    2018-06-05

    Drop-on-demand (DOD) printing is widely used in bioprinting for tissue engineering because of little damage to cell viability and cost-effectiveness. However, satellite droplets may be generated during printing, deviating cells from the desired position and affecting printing position accuracy. Current control on cell injection in DOD printing is primarily based on trial-and-error process, which is time-consuming and inflexible. In this paper, a novel machine learning technology based on Learning-based Cell Injection Control (LCIC) approach is demonstrated for effective DOD printing control while eliminating satellite droplets automatically. The LCIC approach includes a specific computational fluid dynamics (CFD) simulation model of piezoelectric DOD print-head considering inverse piezoelectric effect, which is used instead of repetitive experiments to collect data, and a multilayer perceptron (MLP) network trained by simulation data based on artificial neural network algorithm, using the well-known classification performance of MLP to optimize DOD printing parameters automatically. The test accuracy of the LCIC method was 90%. With the validation of LCIC method by experiments, satellite droplets from piezoelectric DOD printing are reduced significantly, improving the printing efficiency drastically to satisfy requirements of manufacturing precision for printing complex artificial tissues. The LCIC method can be further used to optimize the structure of DOD print-head and cell behaviors.

  20. Introduction of cyclofem once-a-month injectable contraceptive in Mexico.

    PubMed

    Garza-Flores, J; Moraks del Olmo, A; Fuziwara, J L; Figueroa, J G; Alonso, A; Monroy, J; Perez, M; Urbina-Fuentes, M; Guevara, S J; Cedeno, E; Barrios, R; Ferman, J J; Medina, L M; Velazquez, E; Perez-Palacios, G

    1998-07-01

    A large introductory study of Cyclofem, a once-a-month injectable contraceptive, was conducted in three Mexican provinces. A total of 3457 healthy women participated: 640 women from rural areas (community-based component) and 2817 women from urban and suburban areas (health center-based component). A total of 20,316 women-months of treatment experience were accumulated during a one year period. Cyclofem proved its use-effectiveness (pregnancy rate of 0.03%) and its safety under routine service conditions of family planning facilities in Mexico. The overall life table continuation rate at 1 year was 26.1%. Higher continuation rates were observed in the community-based component (36.6%) as compared to the health center component (23.7%). The most common reason for method discontinuation was change of address. Only 15% of the discontinuations were attributable to the injectable contraceptive method, with the overall 1 year discontinuation rate for bleeding problems (including amenorrhea) was < 11%. These observations underscore the importance of appropriate counseling and follow-up measures, providing convenient access to repeat injections, and other service delivery issues related to continuation of Cyclofem. The results of this trial have once again demonstrated that Cyclofem is a highly effective method with an acceptable side effect profile. In addition, the study provided the elements for its approval by local health authorities and its inclusion into the Ministry of Health Family Planning Program.

  1. Optimization research on the concentration field of NO in selective catalytic reduction flue gas denitration system

    NASA Astrophysics Data System (ADS)

    Zheng, Qingyu; Zhang, Guoqiang; Che, Kai; Shao, Shikuan; Li, Yanfei

    2017-08-01

    Taking 660 MW generator unit denitration system as a study object, an optimization and adjustment method shall be designed to control ammonia slip, i.e. adjust ammonia injection system based on NO concentration distribution at inlet/outlet of the denitration system to make the injected ammonia distribute evenly. The results shows that, this method can effectively improve NO concentration distribution at outlet of the denitration system and decrease ammonia injection amount and ammonia slip concentration. Reduce adverse impact of SCR denitration process on the air preheater to realize safe production by guaranteeing that NO discharge shall reach the standard.

  2. Fracture Propagation, Fluid Flow, and Geomechanics of Water-Based Hydraulic Fracturing in Shale Gas Systems and Electromagnetic Geophysical Monitoring of Fluid Migration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Jihoon; Um, Evan; Moridis, George

    2014-12-01

    We investigate fracture propagation induced by hydraulic fracturing with water injection, using numerical simulation. For rigorous, full 3D modeling, we employ a numerical method that can model failure resulting from tensile and shear stresses, dynamic nonlinear permeability, leak-off in all directions, and thermo-poro-mechanical effects with the double porosity approach. Our numerical results indicate that fracture propagation is not the same as propagation of the water front, because fracturing is governed by geomechanics, whereas water saturation is determined by fluid flow. At early times, the water saturation front is almost identical to the fracture tip, suggesting that the fracture is mostlymore » filled with injected water. However, at late times, advance of the water front is retarded compared to fracture propagation, yielding a significant gap between the water front and the fracture top, which is filled with reservoir gas. We also find considerable leak-off of water to the reservoir. The inconsistency between the fracture volume and the volume of injected water cannot properly calculate the fracture length, when it is estimated based on the simple assumption that the fracture is fully saturated with injected water. As an example of flow-geomechanical responses, we identify pressure fluctuation under constant water injection, because hydraulic fracturing is itself a set of many failure processes, in which pressure consistently drops when failure occurs, but fluctuation decreases as the fracture length grows. We also study application of electromagnetic (EM) geophysical methods, because these methods are highly sensitive to changes in porosity and pore-fluid properties due to water injection into gas reservoirs. Employing a 3D finite-element EM geophysical simulator, we evaluate the sensitivity of the crosswell EM method for monitoring fluid movements in shaly reservoirs. For this sensitivity evaluation, reservoir models are generated through the coupled flow-geomechanical simulator and are transformed via a rock-physics model into electrical conductivity models. It is shown that anomalous conductivity distribution in the resulting models is closely related to injected water saturation, but not closely related to newly created unsaturated fractures. Our numerical modeling experiments demonstrate that the crosswell EM method can be highly sensitive to conductivity changes that directly indicate the migration pathways of the injected fluid. Accordingly, the EM method can serve as an effective monitoring tool for distribution of injected fluids (i.e., migration pathways) during hydraulic fracturing operations« less

  3. Intratympanic Iodine Contrast Injection Diffuses Across the Round Window Membrane Allowing for Perilymphatic CT Volume Acquisition Imaging

    PubMed Central

    Abt, Nicholas B.; Lehar, Mohamed; Guajardo, Carolina Trevino; Penninger, Richard T.; Ward, Bryan K.; Pearl, Monica S.; Carey, John P.

    2016-01-01

    Hypothesis Whether the RWM is permeable to iodine-based contrast agents (IBCA) is unknown; therefore, our goal was to determine if IBCAs could diffuse through the RWM using CT volume acquisition imaging. Introduction Imaging of hydrops in the living human ear has attracted recent interest. Intratympanic (IT) injection has shown gadolinium's ability to diffuse through the round window membrane (RWM), enhancing the perilymphatic space. Methods Four unfixed human cadaver temporal bones underwent intratympanic IBCA injection using three sequentially studied methods. The first method was direct IT injection. The second method used direct RWM visualization via tympanomeatal flap for IBCA-soaked absorbable gelatin pledget placement. In the third method, the middle ear was filled with contrast after flap elevation. Volume acquisition CT images were obtained immediately post-exposure, and at 1, 6, and 24 hour intervals. Post-processing was accomplished using color ramping and subtraction imaging. Results Following the third method, positive RWM and perilymphatic enhancement were seen with endolymph sparing. Gray scale and color ramp multiplanar reconstructions displayed increased signal within the cochlea compared to pre-contrast imaging. The cochlea was measured for attenuation differences compared to pure water, revealing a pre-injection average of −1,103 HU and a post-injection average of 338 HU. Subtraction imaging shows enhancement remaining within the cochlear space, Eustachian tube, middle ear epithelial lining, and mastoid. Conclusions Iohexol iodine contrast is able to diffuse across the RWM. Volume acquisition CT imaging was able to detect perilymphatic enhancement at 0.5mm slice thickness. The clinical application of IBCA IT injection appears promising but requires further safety studies. PMID:26859543

  4. Diverse HIV epidemics among people who inject drugs in Thailand: Evidence from respondent-driven sampling surveys in Bangkok and Chiang Mai☆

    PubMed Central

    Prybylski, Dimitri; Manopaiboon, Chomnad; Visavakum, Prin; Yongvanitjit, Kovit; Aramrattana, Apinun; Manomaipiboon, Parnrudee; Tanpradech, Suvimon; Suksripanich, Orapin; Pattanasin, Sarika; Wolfe, Mitchell; Whitehead, Sara J.

    2016-01-01

    Background Thailand’s long-standing HIV sero-sentinel surveillance system for people who inject drugs (PWID) is confined to those in methadone-based drug treatment clinics and representative data are scarce, especially outside of Bangkok. Methods We conducted probability-based respondent-driven sampling (RDS) surveys in Bangkok (n = 738) and Chiang Mai (n = 309) to increase understanding of local HIV epidemics and to better inform the planning of evidence-based interventions. Results PWID had different epidemiological profiles in these two cities. Overall HIV prevalence was higher in Bangkok (23.6% vs. 10.9%, p < 0.001) but PWID in Bangkok are older and appear to have long-standing HIV infections. In Chiang Mai, HIV infections appear to be more recently acquired and PWID were younger and had higher levels of recent injecting and sexual risk behaviors with lower levels of intervention exposure. Methamphetamine was the predominant drug injected in both sites and polydrug use was common although levels and patterns of the specific drugs injected varied significantly between the sites. In multivariate analysis, recent midazolam injection was significantly associated with HIV infection in Chiang Mai (adjusted odds ratio = 8.1; 95% confidence interval: 1.2–54.5) whereas in Bangkok HIV status was not associated with recent risk behaviors as infections had likely been acquired in the past. Conclusion PWID epidemics in Thailand are heterogeneous and driven by local factors. There is a need to customize intervention strategies for PWID in different settings and to integrate population-based survey methods such as RDS into routine surveillance to monitor the national response. PMID:25640153

  5. Optimized and validated flow-injection spectrophotometric analysis of topiramate, piracetam and levetiracetam in pharmaceutical formulations.

    PubMed

    Hadad, Ghada M; Abdel-Salam, Randa A; Emara, Samy

    2011-12-01

    Application of a sensitive and rapid flow injection analysis (FIA) method for determination of topiramate, piracetam, and levetiracetam in pharmaceutical formulations has been investigated. The method is based on the reaction with ortho-phtalaldehyde and 2-mercaptoethanol in a basic buffer and measurement of absorbance at 295 nm under flow conditions. Variables affecting the determination such as sample injection volume, pH, ionic strength, reagent concentrations, flow rate of reagent and other FIA parameters were optimized to produce the most sensitive and reproducible results using a quarter-fraction factorial design, for five factors at two levels. Also, the method has been optimized and fully validated in terms of linearity and range, limit of detection and quantitation, precision, selectivity and accuracy. The method was successfully applied to the analysis of pharmaceutical preparations.

  6. Correction for FDG PET dose extravasations: Monte Carlo validation and quantitative evaluation of patient studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silva-Rodríguez, Jesús, E-mail: jesus.silva.rodriguez@sergas.es; Aguiar, Pablo, E-mail: pablo.aguiar.fernandez@sergas.es; Servicio de Medicina Nuclear, Complexo Hospitalario Universidade de Santiago de Compostela

    Purpose: Current procedure guidelines for whole body [18F]fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography (PET) state that studies with visible dose extravasations should be rejected for quantification protocols. Our work is focused on the development and validation of methods for estimating extravasated doses in order to correct standard uptake value (SUV) values for this effect in clinical routine. Methods: One thousand three hundred sixty-seven consecutive whole body FDG-PET studies were visually inspected looking for extravasation cases. Two methods for estimating the extravasated dose were proposed and validated in different scenarios using Monte Carlo simulations. All visible extravasations were retrospectively evaluated using a manualmore » ROI based method. In addition, the 50 patients with higher extravasated doses were also evaluated using a threshold-based method. Results: Simulation studies showed that the proposed methods for estimating extravasated doses allow us to compensate the impact of extravasations on SUV values with an error below 5%. The quantitative evaluation of patient studies revealed that paravenous injection is a relatively frequent effect (18%) with a small fraction of patients presenting considerable extravasations ranging from 1% to a maximum of 22% of the injected dose. A criterion based on the extravasated volume and maximum concentration was established in order to identify this fraction of patients that might be corrected for paravenous injection effect. Conclusions: The authors propose the use of a manual ROI based method for estimating the effectively administered FDG dose and then correct SUV quantification in those patients fulfilling the proposed criterion.« less

  7. Fluid Flow Prediction with Development System Interwell Connectivity Influence

    NASA Astrophysics Data System (ADS)

    Bolshakov, M.; Deeva, T.; Pustovskikh, A.

    2016-03-01

    In this paper interwell connectivity has been studied. First of all, literature review of existing methods was made which is divided into three groups: Statistically-Based Methods, Material (fluid) Propagation-Based Methods and Potential (pressure) Change Propagation-Based Method. The disadvantages of the first and second groups are as follows: methods do not involve fluid flow through porous media, ignore any changes of well conditions (BHP, skin factor, etc.). The last group considers changes of well conditions and fluid flow through porous media. In this work Capacitance method (CM) has been chosen for research. This method is based on material balance and uses weight coefficients lambdas to assess well influence. In the next step synthetic model was created for examining CM. This model consists of an injection well and a production well. CM gave good results, it means that flow rates which were calculated by analytical method (CM) show matching with flow rate in model. Further new synthetic model was created which includes six production and one injection wells. This model represents seven-spot pattern. To obtain lambdas weight coefficients, the delta function was entered using by minimization algorithm. Also synthetic model which has three injectors and thirteen producer wells was created. This model simulates seven-spot pattern production system. Finally Capacitance method (CM) has been adjusted on real data of oil Field Ω. In this case CM does not give enough satisfying results in terms of field data liquid rate. In conclusion, recommendations to simplify CM calculations were given. Field Ω is assumed to have one injection and one production wells. In this case, satisfying results for production rates and cumulative production were obtained.

  8. Tattoo Delivery of a Semliki Forest Virus-Based Vaccine Encoding Human Papillomavirus E6 and E7.

    PubMed

    van de Wall, Stephanie; Walczak, Mateusz; van Rooij, Nienke; Hoogeboom, Baukje-Nynke; Meijerhof, Tjarko; Nijman, Hans W; Daemen, Toos

    2015-03-24

    The skin is an attractive organ for immunization because of the presence of antigen-presenting cells. Intradermal delivery via tattooing has demonstrated superior vaccine immunogenicity of DNA vaccines in comparison to conventional delivery methods. In this study, we explored the efficacy of tattoo injection of a tumor vaccine based on recombinant Semliki Forest virus replicon particles (rSFV) targeting human papillomavirus (HPV). Tattoo injection of rSFV particles resulted in antigen expression in both the skin and draining lymph nodes. In comparison with intramuscular injection, the overall antigen expression determined at the site of administration and draining lymph nodes was 10-fold lower upon tattoo injection. Delivery of SFV particles encoding the E6 and E7 antigens of human papillomavirus type 16 (SFVeE6,7) via tattooing resulted in HPV-specific cytotoxic T cells and in vivo therapeutic antitumor response. Strikingly, despite the observed lower overall transgene expression, SFVeE6,7 delivered via tattoo injection resulted in higher or equal levels of immune responses as compared to intramuscular injection. The intrinsic immunogenic potential of tattooing provides a benefit for immunotherapy based on an alphavirus.

  9. Tattoo Delivery of a Semliki Forest Virus-Based Vaccine Encoding Human Papillomavirus E6 and E7

    PubMed Central

    van de Wall, Stephanie; Walczak, Mateusz; van Rooij, Nienke; Hoogeboom, Baukje-Nynke; Meijerhof, Tjarko; Nijman, Hans W.; Daemen, Toos

    2015-01-01

    The skin is an attractive organ for immunization because of the presence of antigen-presenting cells. Intradermal delivery via tattooing has demonstrated superior vaccine immunogenicity of DNA vaccines in comparison to conventional delivery methods. In this study, we explored the efficacy of tattoo injection of a tumor vaccine based on recombinant Semliki Forest virus replicon particles (rSFV) targeting human papillomavirus (HPV). Tattoo injection of rSFV particles resulted in antigen expression in both the skin and draining lymph nodes. In comparison with intramuscular injection, the overall antigen expression determined at the site of administration and draining lymph nodes was 10-fold lower upon tattoo injection. Delivery of SFV particles encoding the E6 and E7 antigens of human papillomavirus type 16 (SFVeE6,7) via tattooing resulted in HPV-specific cytotoxic T cells and in vivo therapeutic antitumor response. Strikingly, despite the observed lower overall transgene expression, SFVeE6,7 delivered via tattoo injection resulted in higher or equal levels of immune responses as compared to intramuscular injection. The intrinsic immunogenic potential of tattooing provides a benefit for immunotherapy based on an alphavirus. PMID:26343186

  10. Young women's attitudes toward injectable and implantable contraceptives.

    PubMed

    Gold, M A; Coupey, S M

    1998-02-01

    To assess the potential acceptability of implantable and injectable contraceptive characteristics by young women of diverse ethnic and educational backgrounds. A cross-sectional self-administered survey. The waiting room of three clinical sites: an elite women's college health service, a coeducational state university health service, and an inner city hospital-based adolescent clinic. 328 young women awaiting medical care in one of three clinical sites, aged 13 to 21 years (85% 18-21 years); ethnic distribution differed significantly by site. The majority (83%) were sexually active, and of those who were sexually experienced, 25% had been pregnant. A 47-item questionnaire examining attitudes toward characteristics of injectable and implantable contraceptive methods, menstrual, sexual, and gynecologic history. Sixty-two percent of the sample agreed that they would get an injectable method. There was little variation in agreement to get an injectable method by sexual or pregnancy history. Fewer subjects (24%) agreed that they would like to get subdermal implants and agreement to get an implantable method of contraception did not vary by sexual history; however, ever-pregnant young women (33%) were significantly more likely to agree to implants than never-pregnant subjects (21%; chi2, 4.109; p = 0.04). Seventy-four percent of subjects said they would stop using a contraceptive that caused irregular menses, whereas 65% would stop using a method that caused amenorrhea. An injectable contraceptive method has universal appeal across ethnic, educational, and age categories, whereas implants are less appealing. Irregular bleeding and amenorrhea are poorly perceived side effects of long-acting contraceptives.

  11. [Clinical outcomes research of use of Shenfu injection based on hospital information system].

    PubMed

    Yang, Jing; Zhao, Ruo-Qi; Xie, Yan-Ming; Yang, Hu; Li, Lin; Zhuang, Yan

    2012-09-01

    To know how Shenfu injection is used in clinical practice and to provide a reference for guiding clinical use of Shenfu injection. Extract Shenfu injection's post-marketing re-evaluation data from the hospital information system (HIS) of 20 national grade III-A General Hospitals, use basic statistical analysis methods to analyze Shenfu injection's indications, usage and dosage, treatment course etc. in clinical practice. In patients using Shenfu injection, the average age was 62. 15, and patients mainly concentrated in cardiovascular medicine. In clinical practice, Shenfu injection was used mainly for treatment of coronary heart disease (diagnosed as chest obstruction in traditional Chinese medicine). The treatment course mainly ranged from 3 to 7 days, and the dosage was within the limits prescribed by the instruction. Shenfu injection was mainly used for elderly patients, and has been used according to instruction in practice almostly.

  12. [Onyx embolization for treatment of dural arteriovenous fistula: comparison of long- distance versus routine injection method].

    PubMed

    He, Xiao-Yan; Zhang, Guo-Zhong; Li, Ming-Zhou; Wang, Gang; Liu, Dan; Qi, Song-Tao; Li, Wei-Guang; Feng, Wen-Feng

    2016-03-01

    To compare the efficacy, clinical characteristics, safety, injection time and radiation exposure of Onyx embolization using a long-distance injection method and routine injection method for management of dural arteriovenous fistula (DAVF). The clinical data were retrospectively analyzed in 59 patients with DAVF treated with Onyx embolization using long-distance injection method (28 patients) and routine injection method (31 patients). The efficacy, safety, injection time and radiation exposure during Onyx embolization were compared between the two injections methods. The average radiation dose exposure to the surgeon per procedure was significantly lower in the long-distance injection group than in the routine group. The injection time (P=0.53), injection volume (P=0.78), number of supply arteries (P=0.80), Cognard types (P=0.67), and effect of embolization (P=0.88) were all similar between the two groups. Endovaseular treatment of intracranial DAVF with Onyx embolization using the long-distance injection method is feasible, safe and effective and can reduce the radiation exposure to the surgeon.

  13. A volumetric flow sensor for automotive injection systems

    NASA Astrophysics Data System (ADS)

    Schmid, U.; Krötz, G.; Schmitt-Landsiedel, D.

    2008-04-01

    For further optimization of the automotive power train of diesel engines, advanced combustion processes require a highly flexible injection system, provided e.g. by the common rail (CR) injection technique. In the past, the feasibility to implement injection nozzle volumetric flow sensors based on the thermo-resistive measurement principle has been demonstrated up to injection pressures of 135 MPa (1350 bar). To evaluate the transient behaviour of the system-integrated flow sensors as well as an injection amount indicator used as a reference method, hydraulic simulations on the system level are performed for a CR injection system. Experimentally determined injection timings were found to be in good agreement with calculated values, especially for the novel sensing element which is directly implemented into the hydraulic system. For the first time pressure oscillations occurring after termination of the injection pulse, predicted theoretically, could be verified directly in the nozzle. In addition, the injected amount of fuel is monitored with the highest resolution ever reported in the literature.

  14. A novel technique based on in vitro oocyte injection to improve CRISPR/Cas9 gene editing in zebrafish

    PubMed Central

    Xie, Shao-Lin; Bian, Wan-Ping; Wang, Chao; Junaid, Muhammad; Zou, Ji-Xing; Pei, De-Sheng

    2016-01-01

    Contemporary improvements in the type II clustered regularly interspaced short palindromic repeats/CRISPR-associated protein 9 (CRISPR/Cas9) system offer a convenient way for genome editing in zebrafish. However, the low efficiencies of genome editing and germline transmission require a time-intensive and laborious screening work. Here, we reported a method based on in vitro oocyte storage by injecting oocytes in advance and incubating them in oocyte storage medium to significantly improve the efficiencies of genome editing and germline transmission by in vitro fertilization (IVF) in zebrafish. Compared to conventional methods, the prior micro-injection of zebrafish oocytes improved the efficiency of genome editing, especially for the sgRNAs with low targeting efficiency. Due to high throughputs, simplicity and flexible design, this novel strategy will provide an efficient alternative to increase the speed of generating heritable mutants in zebrafish by using CRISPR/Cas9 system. PMID:27680290

  15. Validation of a stability-indicating hydrophilic interaction liquid chromatographic method for the quantitative determination of vitamin k3 (menadione sodium bisulfite) in injectable solution formulation.

    PubMed

    Ghanem, Mashhour M; Abu-Lafi, Saleh A; Hallak, Hussein O

    2013-01-01

    A simple, specific, accurate, and stability-indicating method was developed and validated for the quantitative determination of menadione sodium bisulfite in the injectable solution formulation. The method is based on zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) coupled with a photodiode array detector. The desired separation was achieved on the ZIC-HILIC column (250 mm × 4.6 mm, 5 μm) at 25°C temperature. The optimized mobile phase consisted of an isocratic solvent mixture of 200mM ammonium acetate (NH4AC) solution and acetonitrile (ACN) (20:80; v/v) pH-adjusted to 5.7 by glacial acetic acid. The mobile phase was fixed at 0.5 ml/min and the analytes were monitored at 261 nm using a photodiode array detector. The effects of the chromatographic conditions on the peak retention, peak USP tailing factor, and column efficiency were systematically optimized. Forced degradation experiments were carried out by exposing menadione sodium bisulfite standard and the injectable solution formulation to thermal, photolytic, oxidative, and acid-base hydrolytic stress conditions. The degradation products were well-resolved from the main peak and the excipients, thus proving that the method is a reliable, stability-indicating tool. The method was validated as per ICH and USP guidelines (USP34/NF29) and found to be adequate for the routine quantitative estimation of menadione sodium bisulfite in commercially available menadione sodium bisulfite injectable solution dosage forms.

  16. Injection of thermal and suprathermal seed particles into coronal shocks of varying obliquity

    NASA Astrophysics Data System (ADS)

    Battarbee, M.; Vainio, R.; Laitinen, T.; Hietala, H.

    2013-10-01

    Context. Diffusive shock acceleration in the solar corona can accelerate solar energetic particles to very high energies. Acceleration efficiency is increased by entrapment through self-generated waves, which is highly dependent on the amount of accelerated particles. This, in turn, is determined by the efficiency of particle injection into the acceleration process. Aims: We present an analysis of the injection efficiency at coronal shocks of varying obliquity. We assessed injection through reflection and downstream scattering, including the effect of a cross-shock potential. Both quasi-thermal and suprathermal seed populations were analysed. We present results on the effect of cross-field diffusion downstream of the shock on the injection efficiency. Methods: Using analytical methods, we present applicable injection speed thresholds that were compared with both semi-analytical flux integration and Monte Carlo simulations, which do not resort to binary thresholds. Shock-normal angle θBn and shock-normal velocity Vs were varied to assess the injection efficiency with respect to these parameters. Results: We present evidence of a significant bias of thermal seed particle injection at small shock-normal angles. We show that downstream isotropisation methods affect the θBn-dependence of this result. We show a non-negligible effect caused by the cross-shock potential, and that the effect of downstream cross-field diffusion is highly dependent on boundary definitions. Conclusions: Our results show that for Monte Carlo simulations of coronal shock acceleration a full distribution function assessment with downstream isotropisation through scatterings is necessary to realistically model particle injection. Based on our results, seed particle injection at quasi-parallel coronal shocks can result in significant acceleration efficiency, especially when combined with varying field-line geometry. Appendices are available in electronic form at http://www.aanda.org

  17. CO 2 water-alternating-gas injection for enhanced oil recovery: Optimal well controls and half-cycle lengths

    DOE PAGES

    Chen, Bailian; Reynolds, Albert C.

    2018-03-11

    We report that CO 2 water-alternating-gas (WAG) injection is an enhanced oil recovery method designed to improve sweep efficiency during CO 2 injection with the injected water to control the mobility of CO 2 and to stabilize the gas front. Optimization of CO 2 -WAG injection is widely regarded as a viable technique for controlling the CO 2 and oil miscible process. Poor recovery from CO 2 -WAG injection can be caused by inappropriately designed WAG parameters. In previous study (Chen and Reynolds, 2016), we proposed an algorithm to optimize the well controls which maximize the life-cycle net-present-value (NPV). However,more » the effect of injection half-cycle lengths for each injector on oil recovery or NPV has not been well investigated. In this paper, an optimization framework based on augmented Lagrangian method and the newly developed stochastic-simplex-approximate-gradient (StoSAG) algorithm is proposed to explore the possibility of simultaneous optimization of the WAG half-cycle lengths together with the well controls. Finally, the proposed framework is demonstrated with three reservoir examples.« less

  18. CO 2 water-alternating-gas injection for enhanced oil recovery: Optimal well controls and half-cycle lengths

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Bailian; Reynolds, Albert C.

    We report that CO 2 water-alternating-gas (WAG) injection is an enhanced oil recovery method designed to improve sweep efficiency during CO 2 injection with the injected water to control the mobility of CO 2 and to stabilize the gas front. Optimization of CO 2 -WAG injection is widely regarded as a viable technique for controlling the CO 2 and oil miscible process. Poor recovery from CO 2 -WAG injection can be caused by inappropriately designed WAG parameters. In previous study (Chen and Reynolds, 2016), we proposed an algorithm to optimize the well controls which maximize the life-cycle net-present-value (NPV). However,more » the effect of injection half-cycle lengths for each injector on oil recovery or NPV has not been well investigated. In this paper, an optimization framework based on augmented Lagrangian method and the newly developed stochastic-simplex-approximate-gradient (StoSAG) algorithm is proposed to explore the possibility of simultaneous optimization of the WAG half-cycle lengths together with the well controls. Finally, the proposed framework is demonstrated with three reservoir examples.« less

  19. Delineating Area of Review in a System with Pre-injection Relative Overpressure

    DOE PAGES

    Oldenburg, Curtis M.; Cihan, Abdullah; Zhou, Quanlin; ...

    2014-12-31

    The Class VI permit application for geologic carbon sequestration (GCS) requires delineation of an area of review (AoR), defined as the region surrounding the (GCS) project where underground sources of drinking water (USDWs) may be endangered. The methods for estimating AoR under the Class VI regulation were developed assuming that GCS reservoirs would be in hydrostatic equilibrium with overlying aquifers. Here we develop and apply an approach to estimating AoR for sites with preinjection relative overpressure for which standard AoR estimation methods produces an infinite AoR. The approach we take is to compare brine leakage through a hypothetical open flowmore » path in the base-case scenario (no-injection) to the incrementally larger leakage that would occur in the CO 2-injection case. To estimate AoR by this method, we used semi-analytical solutions to single-phase flow equations to model reservoir pressurization and flow up (single) leaky wells located at progressively greater distances from the injection well. We found that the incrementally larger flow rates for hypothetical leaky wells located 6 km and 4 km from the injection well are ~20% and 30% greater, respectively, than hypothetical baseline leakage rates. If total brine leakage is considered, the results depend strongly on how the incremental increase in total leakage is calculated, varying from a few percent to up to 40% greater (at most at early time) than base-case total leakage.« less

  20. Simultaneous Treatment with Subcutaneous Injection of Golimumab and Intra-articular Injection of Triamcinolone Acetonide (K-Method) in Patients with Rheumatoid Arthritis Undergoing Switching of Biologics: Retrospective Case–Control Study

    PubMed Central

    Kanbe, Katsuaki; Chiba, Junji; Inoue, Yasuo; Taguchi, Masashi; Yabuki, Akiko; Deguchi, Tomohiko

    2016-01-01

    BACKGROUND Tight control of severe rheumatoid arthritis (RA) in patients with high disease activity, even when using biologics, is sometimes difficult using a treat-to-target strategy. Switching from one biologic to another is associated with lower efficacy than that in treatment-naive cases. We developed the K-method that involves simultaneous treatment with golimumab and intra-articular joint injection of triamcinolone acetonide (TA) in patients undergoing switching of biologics. We performed this retrospective case–control study to investigate the efficacy of achieving an immediate treatment response using the K-method. METHODS This study involved 20 patients with RA (control group, 10 patients; K-method group, 10 patients). Patients in the control group were switched to golimumab from other biologics without intra-articular injection of TA. The K-method involved injection of 1 mL of TA (40 mg/mL) and 2 mL of 1% lidocaine hydrochloride into swollen or painful joints on the same day as golimumab treatment. A quick response one day after treatment was compared between the two groups according to the disease activity score 28 based on C-reactive protein (DAS28 CRP), clinical disease activity index (CDAI), simplified disease activity index (SDAI), European League Against Rheumatism (EULAR) response, and remission rate. These parameters were investigated for 24 weeks. RESULTS The K-method group showed significant improvements in DAS28 CRP, CDAI, and SDAI at one day, 12 weeks, and 24 weeks compared with the control group. The number of swollen and tender joints and the patient and doctor global visual analog scale scores were also significantly different between the two groups. The remission rates based on DAS28 CRP were 30% at one day, 50% at 12 weeks, and 60% at 24 weeks in the K-method group. The EULAR good/moderate response rates were 80% at one day, 90% at 12 weeks, and 90% at 24 weeks in the K-method group; however, these rates were only 10%, 40%, and 40%, respectively, in the control group. No adverse events occurred in either group. CONCLUSION Simultaneous treatment with biologics and intra-articular injection of TA is useful for cases involving switching of biologics for RA. This strategy is safe and practical for RA treatment. PMID:27081319

  1. Correction for FDG PET dose extravasations: Monte Carlo validation and quantitative evaluation of patient studies.

    PubMed

    Silva-Rodríguez, Jesús; Aguiar, Pablo; Sánchez, Manuel; Mosquera, Javier; Luna-Vega, Víctor; Cortés, Julia; Garrido, Miguel; Pombar, Miguel; Ruibal, Alvaro

    2014-05-01

    Current procedure guidelines for whole body [18F]fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography (PET) state that studies with visible dose extravasations should be rejected for quantification protocols. Our work is focused on the development and validation of methods for estimating extravasated doses in order to correct standard uptake value (SUV) values for this effect in clinical routine. One thousand three hundred sixty-seven consecutive whole body FDG-PET studies were visually inspected looking for extravasation cases. Two methods for estimating the extravasated dose were proposed and validated in different scenarios using Monte Carlo simulations. All visible extravasations were retrospectively evaluated using a manual ROI based method. In addition, the 50 patients with higher extravasated doses were also evaluated using a threshold-based method. Simulation studies showed that the proposed methods for estimating extravasated doses allow us to compensate the impact of extravasations on SUV values with an error below 5%. The quantitative evaluation of patient studies revealed that paravenous injection is a relatively frequent effect (18%) with a small fraction of patients presenting considerable extravasations ranging from 1% to a maximum of 22% of the injected dose. A criterion based on the extravasated volume and maximum concentration was established in order to identify this fraction of patients that might be corrected for paravenous injection effect. The authors propose the use of a manual ROI based method for estimating the effectively administered FDG dose and then correct SUV quantification in those patients fulfilling the proposed criterion.

  2. Analog-digital simulation of transient-induced logic errors and upset susceptibility of an advanced control system

    NASA Technical Reports Server (NTRS)

    Carreno, Victor A.; Choi, G.; Iyer, R. K.

    1990-01-01

    A simulation study is described which predicts the susceptibility of an advanced control system to electrical transients resulting in logic errors, latched errors, error propagation, and digital upset. The system is based on a custom-designed microprocessor and it incorporates fault-tolerant techniques. The system under test and the method to perform the transient injection experiment are described. Results for 2100 transient injections are analyzed and classified according to charge level, type of error, and location of injection.

  3. Analysis of charge injection and contact resistance as a function of electrode surface treatment in ambipolar polymer transistors

    NASA Astrophysics Data System (ADS)

    Lee, Seon Jeng; Kim, Chaewon; Jung, Seok-Heon; Di Pietro, Riccardo; Lee, Jin-Kyun; Kim, Jiyoung; Kim, Miso; Lee, Mi Jung

    2018-01-01

    Ambipolar organic field-effect transistors (OFETs) have both of hole and electron enhancements in charge transport. The characteristics of conjugated diketopyrrolopyrrole ambipolar OFETs depend on the metal-contact surface treatment for charge injection. To investigate the charge-injection characteristics of ambipolar transistors, these devices are processed via various types of self-assembled monolayer treatments and annealing. We conclude that treatment by the self-assembled monolayer 1-decanethiol gives the best enhancement of electron charge injection at both 100 and 300 °C annealing temperature. In addition, the contact resistance is calculated by using two methods: One is the gated four-point probe (gFPP) method that gives the voltage drop between channels, and the other is the simultaneous contact resistance extraction method, which extracts the contact resistance from the general transfer curve. We confirm that the gFPP method and the simultaneous extraction method give similar contact resistance, which means that we can extract contact resistance from the general transfer curve without any special contact pattern. Based on these characteristics of ambipolar p- and n-type transistors, we fabricate inverter devices with only one active layer. [Figure not available: see fulltext.

  4. Review and test of chilldown methods for space-based cryogenic tanks

    NASA Astrophysics Data System (ADS)

    Chato, David J.; Sanabria, Rafael

    The literature for tank chilldown methods applicable to cryogenic tankage in the zero gravity environment of earth orbit is reviewed. One method is selected for demonstration in a ground based test. The method selected for investigation was the charge-hold-vent method which uses repeated injection of liquid slugs, followed by a hold to allow complete vaporization of the liquid and a vent of the tank to space vacuum to cool tankage to the desired temperature. The test was conducted on a 175 cubic foot, 2219 aluminum walled tank weighing 329 pounds, which was previously outfitted with spray systems to test nonvented fill technologies. To minimize hardware changes, a simple control-by-pressure scheme was implemented to control injected liquid quantities. The tank cooled from 440 R sufficiently in six charge-hold-vent cycles to allow a complete nonvented fill of the test tank. Liquid hydrogen consumed in the process is estimated at 32 pounds.

  5. Review and test of chilldown methods for space-based cryogenic tanks

    NASA Technical Reports Server (NTRS)

    Chato, David J.; Sanabria, Rafael

    1991-01-01

    The literature for tank chilldown methods applicable to cryogenic tankage in the zero gravity environment of earth orbit is reviewed. One method is selected for demonstration in a ground based test. The method selected for investigation was the charge-hold-vent method which uses repeated injection of liquid slugs, followed by a hold to allow complete vaporization of the liquid and a vent of the tank to space vacuum to cool tankage to the desired temperature. The test was conducted on a 175 cubic foot, 2219 aluminum walled tank weighing 329 pounds, which was previously outfitted with spray systems to test nonvented fill technologies. To minimize hardware changes, a simple control-by-pressure scheme was implemented to control injected liquid quantities. The tank cooled from 440 R sufficiently in six charge-hold-vent cycles to allow a complete nonvented fill of the test tank. Liquid hydrogen consumed in the process is estimated at 32 pounds.

  6. 40 CFR 146.95 - Class VI injection depth waiver requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... detection tools), unless the Director determines, based on site-specific geology, that such methods are not... geology, that such methods are not appropriate; (5) Any additional requirements requested by the Director...

  7. Respondent-driven sampling and the recruitment of people with small injecting networks.

    PubMed

    Paquette, Dana; Bryant, Joanne; de Wit, John

    2012-05-01

    Respondent-driven sampling (RDS) is a form of chain-referral sampling, similar to snowball sampling, which was developed to reach hidden populations such as people who inject drugs (PWID). RDS is said to reach members of a hidden population that may not be accessible through other sampling methods. However, less attention has been paid as to whether there are segments of the population that are more likely to be missed by RDS. This study examined the ability of RDS to capture people with small injecting networks. A study of PWID, using RDS, was conducted in 2009 in Sydney, Australia. The size of participants' injecting networks was examined by recruitment chain and wave. Participants' injecting network characteristics were compared to those of participants from a separate pharmacy-based study. A logistic regression analysis was conducted to examine the characteristics independently associated with having small injecting networks, using the combined RDS and pharmacy-based samples. In comparison with the pharmacy-recruited participants, RDS participants were almost 80% less likely to have small injecting networks, after adjusting for other variables. RDS participants were also more likely to have their injecting networks form a larger proportion of those in their social networks, and to have acquaintances as part of their injecting networks. Compared to those with larger injecting networks, individuals with small injecting networks were equally likely to engage in receptive sharing of injecting equipment, but less likely to have had contact with prevention services. These findings suggest that those with small injecting networks are an important group to recruit, and that RDS is less likely to capture these individuals.

  8. Evaluation of the acute and chronic safety of the biosense injection catheter system in porcine hearts.

    PubMed

    Kornowski, R; Fuchs, S; Tio, F O; Pierre, A; Epstein, S E; Leon, M B

    1999-12-01

    Direct myocardial injection of therapeutic agents has been explored as a new method for myocardial revascularization. The integration of a 3D electromechanical mapping catheter with a retractable injection needle should allow for intramyocardial injection to identified sites, obviating the need for open heart surgery. This study assessed the procedural safety and performance characteristics of a novel guided catheter-based transendocardial injection system. The electromagnetic guidance system was coupled with a retrievable 27G needle for left ventricular endocardial injection. Using this system, we injected, transendocardially, methylene-blue (MB) dye tracer at a volume of 0.1 or 0.2 ml per injection in eight normal pigs. Animals were sacrificed acutely, at 1, 3, and 7 days (two animal in each time). Three animals served as controls. The injections were followed by coronary angiography and echocardiogram to assess possible ventricular or coronary perforation and wall motion abnormalities. CK-MB levels were measured up to 24 hr following the procedure. The animals were sacrificed at the assigned time for gross and histopathology evaluation. A total of 101 injections were made in all regions of the heart except the apex and the mitral valve. No animal died as a result of the mapping or injection procedures. Vital signs did not change relative to baseline after the mapping and injection procedures. CK-MB values did not increase over time and there was no evidence of sustained arrhythmia or hemodynamic compromise. There was no evidence of left ventricular or coronary perforation, global or regional wall motion abnormalities, or hemopericardium. On histologic evaluation, the estimated volume of tissue staining was greater than the volume of the injected MB dye due to dispersion of the injectate in the interstitial and intracellular fluid compartments. It is concluded that using this magnetic guidance catheter-based navigational system, it is feasible and safe to perform the transendocardial injection procedure. Thus, if it is determined that direct intramyocardial injection of drugs is a valid therapeutic strategy, this approach offers a clear advantage over surgically based transepicardial injection procedures. Cathet. Cardiovasc. Intervent. 48:447-453, 1999. Copyright 1999 Wiley-Liss, Inc.

  9. Influence of design parameters in Water-Alternating-Gas Injection on enhancement of CO2 trapping in heterogeneous formations: A numerical study

    NASA Astrophysics Data System (ADS)

    Joodaki, S.; Yang, Z.; Niemi, A. P.

    2016-12-01

    CO2 trapping in saline aquifers can be enhanced by applying specific injection strategies. Water-alternating-gas (WAG) injection, in which intermittent slugs of CO2 and water are injected, is one of the suggested methods to increase the trapping of CO2 as a result of both capillary forces (residual trapping) and dissolution into the ambient water (dissolution trapping). In this study, 3D numerical modeling was used to investigate the importance of parameters needed to design an effective WAG injection sequence including (i) CO2 and water injection rates, (ii) WAG ratio, (iii) number of cycles and their duration. We employ iTOUGH2-EOS17 model to simulate the CO2 injection and subsequent trapping in heterogeneous formations. Spatially correlated random permeability fields are generated using GSLIB based on available data at the Heletz, a pilot injection site in Israel, aimed for scientifically motivated CO2 injection experiments. Hysteresis effects on relative permeability and capillary pressure function are taken into account based on the Land model (1968). The results showed that both residual and dissolution trapping can be enhanced by increasing in CO2 injection rate due to the fact that higher CO2 injection rate reduces the gravity segregation and increases the reservoir volume swept by CO2. Faster water injection will favor the residual and dissolution trapping due to improved mixing. Increasing total amount of water injection will increase the dissolution trapping but also the cost of the injection. It causes higher pressure increases as well. Using numerical modeling, it is possible to predict the best parameter combination to optimize the trapping and find the balance between safety and cost of the injection process.

  10. Large-volume injection of sample diluents not miscible with the mobile phase as an alternative approach in sample preparation for bioanalysis: an application for fenspiride bioequivalence.

    PubMed

    Medvedovici, Andrei; Udrescu, Stefan; Albu, Florin; Tache, Florentin; David, Victor

    2011-09-01

    Liquid-liquid extraction of target compounds from biological matrices followed by the injection of a large volume from the organic layer into the chromatographic column operated under reversed-phase (RP) conditions would successfully combine the selectivity and the straightforward character of the procedure in order to enhance sensitivity, compared with the usual approach of involving solvent evaporation and residue re-dissolution. Large-volume injection of samples in diluents that are not miscible with the mobile phase was recently introduced in chromatographic practice. The risk of random errors produced during the manipulation of samples is also substantially reduced. A bioanalytical method designed for the bioequivalence of fenspiride containing pharmaceutical formulations was based on a sample preparation procedure involving extraction of the target analyte and the internal standard (trimetazidine) from alkalinized plasma samples in 1-octanol. A volume of 75 µl from the octanol layer was directly injected on a Zorbax SB C18 Rapid Resolution, 50 mm length × 4.6 mm internal diameter × 1.8 µm particle size column, with the RP separation being carried out under gradient elution conditions. Detection was made through positive ESI and MS/MS. Aspects related to method development and validation are discussed. The bioanalytical method was successfully applied to assess bioequivalence of a modified release pharmaceutical formulation containing 80 mg fenspiride hydrochloride during two different studies carried out as single-dose administration under fasting and fed conditions (four arms), and multiple doses administration, respectively. The quality attributes assigned to the bioanalytical method, as resulting from its application to the bioequivalence studies, are highlighted and fully demonstrate that sample preparation based on large-volume injection of immiscible diluents has an increased potential for application in bioanalysis.

  11. Study of Injection of Helium into Supersonic Air Flow Using Rayleigh Scattering

    NASA Technical Reports Server (NTRS)

    Seaholtz, Richard G.; Buggele, Alvin E.

    1997-01-01

    A study of the transverse injection of helium into a Mach 3 crossflow is presented. Filtered Rayleigh scattering is used to measure penetration and helium mole fraction in the mixing region. The method is based on planar molecular Rayleigh scattering using an injection-seeded, frequency-doubled ND:YAG pulsed laser and a cooled CCD camera. The scattered light is filtered with an iodine absorption cell to suppress stray laser light. Preliminary data are presented for helium mole fraction and penetration. Flow visualization images obtained with a shadowgraph and wall static pressure data in the vicinity of the injection are also presented.

  12. Phase measurement by using a forced delay-line oscillator and its application for an acoustic fiber sensor.

    PubMed

    Fleyer, Michael; Horowitz, Moshe

    2018-04-02

    We demonstrate, theoretically and experimentally, a new method to measure small changes in the cavity length of oscillators. The method is based on the high sensitivity of the phase of forced delay-line oscillators to changes in their cavity length. The oscillator phase is directly detected by mixing the oscillator output with the injected signal. We describe a comprehensive theoretical model for studying the signal and the noise at the output of a general forced delay-line oscillator with an instantaneous gain saturation and an amplitude-to-phase conversion. The results indicate that the magnitude and the bandwidth of the oscillator response to a small perturbation can be controlled by adjusting the injection ratio and the injected frequency. For signals with a frequency that is smaller than the device bandwidth, the oscillator noise is dominated by the noise of the injected signal. This noise is highly suppressed by mixing the oscillator output with the injected signal. Hence, the device sensitivity at frequencies below its bandwidth is limited only by the internal noise that is added in a single roundtrip in the oscillator cavity. We demonstrate the use of a forced oscillator as an acoustic fiber sensor in an optoelectronic oscillator. A good agreement is obtained between theory and experiments. The magnitude of the output signal can be controlled by adjusting the injection ratio while the noise power at low frequencies is not enhanced as in sensors that are based on a free-running oscillator.

  13. Renal Sympathetic Denervation by CT-scan-Guided Periarterial Ethanol Injection in Sheep

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Firouznia, Kavous, E-mail: k-firouznia@yahoo.com; Hosseininasab, Sayed jaber, E-mail: dr.hosseininasab@gmail.com; Amanpour, Saeid, E-mail: saeidamanpour@yahoo.com

    BackgroundRenal nerves are a recent target in the treatment of hypertension. Renal sympathetic denervation (RSD) is currently performed using catheter-based radiofrequency ablation (RFA) and because this method has limitations, percutaneous magnetic resonance (MR)-guided periarterial ethanol injection is a suggested alternative. However, few studies have been conducted on the effectiveness of percutaneous ethanol injection for RSD.AimTo evaluate the feasibility, efficacy, and complications of computed tomography (CT)-guided periarterial ethanol injection.MethodsEthanol (10 ml, 99.6 %) was injected around the right renal artery in six sheep under CT guidance with the left kidney serving as a control. Before and after the intervention, the sheep underwent MRmore » imaging studies and the serum creatinine level was measured. One month after the intervention, the sheep were euthanized and norepinephrine (NE) concentration in the renal parenchyma was measured to evaluate the efficacy of the procedure. The treated tissues were also examined histopathologically to evaluate vascular, parenchymal, and neural injury.ResultsThe right kidney parenchymal NE concentration decreased significantly compared with the left kidney after intervention (average reduction: 40 %, P = 0.0016). Histologic examination revealed apparent denervation with no other vascular or parenchymal injuries observed in the histological and imaging studies.ConclusionEffective and feasible RSD was achieved using CT-guided periarterial ethanol injection. This technique may be a potential alternative to catheter-based RFA in the treatment of hypertension.« less

  14. Defining the local nerve blocks for feline distal thoracic limb surgery: a cadaveric study

    PubMed Central

    Enomoto, Masataka; Lascelles, B Duncan X; Gerard, Mathew P

    2016-01-01

    Objectives Though controversial, onychectomy remains a commonly performed distal thoracic limb surgical procedure in cats. Peripheral nerve block techniques have been proposed in cats undergoing onychectomy but evidence of efficacy is lacking. Preliminary tests of the described technique using cadavers resulted in incomplete staining of nerves. The aim of this study was to develop nerve block methods based on cadaveric dissections and test these methods with cadaveric dye injections. Methods Ten pairs of feline thoracic limbs (n = 20) were dissected and superficial branches of the radial nerve (RSbr nn.), median nerve (M n.), dorsal branch of ulnar nerve (UDbr n.), superficial branch of palmar branch of ulnar nerve (UPbrS n.) and deep branch of palmar branch of ulnar nerve (UPbrDp n.) were identified. Based on these dissections, a four-point block was developed and tested using dye injections in another six pairs of feline thoracic limbs (n = 12). Using a 25 G × 5/8 inch needle and 1 ml syringe, 0.07 ml/kg methylene blue was injected at the site of the RSbr nn., 0.04 ml/kg at the injection site of the UDbr n., 0.08 ml/kg at the injection site of the M n. and UPbrS n., and 0.01 ml/kg at the injection site of the UPbrDp n. The length and circumference of each nerve that was stained was measured. Results Positive staining of all nerves was observed in 12/12 limbs. The lengths stained for RSbr nn., M n., UDbr n., UPbrS n. and UPbrDp n. were 34.9 ± 5.3, 26.4 ± 4.8, 29.2 ± 4.0, 39.1 ± 4.3 and 17.5 ± 3.3 mm, respectively. The nerve circumferences stained were 93.8 ± 15.5, 95.8 ± 9.7, 100 ± 0.0, 100 ± 0.0 and 93.8 ± 15.5%, respectively. Conclusions and relevance This described four-point injection method may be an effective perioperative analgesia technique for feline distal thoracic limb procedures. PMID:26250858

  15. Dimensional Changes of Acrylic Resin Denture Bases: Conventional Versus Injection-Molding Technique

    PubMed Central

    Gharechahi, Jafar; Asadzadeh, Nafiseh; Shahabian, Foad; Gharechahi, Maryam

    2014-01-01

    Objective: Acrylic resin denture bases undergo dimensional changes during polymerization. Injection molding techniques are reported to reduce these changes and thereby improve physical properties of denture bases. The aim of this study was to compare dimensional changes of specimens processed by conventional and injection-molding techniques. Materials and Methods: SR-Ivocap Triplex Hot resin was used for conventional pressure-packed and SR-Ivocap High Impact was used for injection-molding techniques. After processing, all the specimens were stored in distilled water at room temperature until measured. For dimensional accuracy evaluation, measurements were recorded at 24-hour, 48-hour and 12-day intervals using a digital caliper with an accuracy of 0.01 mm. Statistical analysis was carried out by SPSS (SPSS Inc., Chicago, IL, USA) using t-test and repeated-measures ANOVA. Statistical significance was defined at P<0.05. Results: After each water storage period, the acrylic specimens produced by injection exhibited less dimensional changes compared to those produced by the conventional technique. Curing shrinkage was compensated by water sorption with an increase in water storage time decreasing dimensional changes. Conclusion: Within the limitations of this study, dimensional changes of acrylic resin specimens were influenced by the molding technique used and SR-Ivocap injection procedure exhibited higher dimensional accuracy compared to conventional molding. PMID:25584050

  16. A line source tracer test - a better method for assessing high groundwater velocity

    NASA Astrophysics Data System (ADS)

    Magal, E.; Weisbrod, N.; Yakirevich, A.; Kurtzman, D.; Yechieli, Y.

    2009-12-01

    A line source injection is suggested as an effective method for assessing groundwater velocities and flow directions in subsurface characterized by high water fluxes. Modifying the common techniques of injecting a tracer into a well was necessary after frequently-used methods of natural and forced gradient tracer tests ended with no reliable information on the local groundwater flow. In a field experiment, tracers were injected into 8-m long line injection system constructed below the water table almost perpendicular to the assumed flow direction. The injection system was divided to four separate segments (each 2 m long) enabling the injection of four different tracers along the line source. An array of five boreholes located in an area of 10x10 m downstream was used for monitoring the tracers' transport. Two dye tracers (Uranine and Na Naphthionate) were injected in a long pulse of several hours into two of the injection pipe segments and two tracers (Rhenium oxide and Gd-DTPA) were instantaneously injected to the other two segments. The tracers were detected 0.7 to 2.3 hours after injection in four of the five observation wells, located 2.3 to 10 m from the injection system, respectively. Groundwater velocities were calculated directly from the tracers' arrival times and by fitting the observed breakthrough curves to simulations with one and two dimensions analytical solutions for conservative tracer transport. The groundwater velocity was determined to be ~100 m/d. The longitudinal dispersivity value, generated from fitting the tracer breakthrough curves, was in a range of 0.2-3m. The groundwater flow direction was derived based on the arrival of the tracers and was found to be consistent with the apparent direction of the hydraulic gradient. The hydraulic conductivity derived from the groundwater velocity was ~1200 m/d, which is in the upper range of gravel sediment.

  17. Control of Viscous Fingering in Miscible Displacements in Porous Media with a Periodic Change of Injection Rate

    NASA Astrophysics Data System (ADS)

    Yuan, Q.; Zeng, F.; Knorr, K. D.; Imran, M.

    2017-12-01

    Context/PurposeThe viscous fingering (VF) is widely encountered in a series of miscible displacements such as CO2 sequestration and solvent-based enhanced oil recovery (EOR). Accurate prediction and effective control of its development are significant. Commercial simulators cannot capture VF because of large numerical diffusion. Moreover, previous measures for controlling VF using polymer are very expensive. In the present study, a periodic change of injection rate involving injection and extraction is used to control and reduce VF instabilities at zero cost. MethodsHighly accurate spectral method and fully implicit alternating direction implicit method are used to simulate VF with concentration-dependent diffusion (CDD) and velocity-induced dispersion (VID), although the consideration of CDD and VID may result in strong nonlinearity and stiff problem under unfavourable viscosity ratio. In-house code is developed. The VF is reduced by optimizing period and amplitude of injection rate. ResultsThe results show that the periodic change of injection rates can strongly affect VF and sweep efficiency. In particular, a period-stabilizing range is found in which the VF is reduced compared with widely used constant injection with the same amount of fluid injected. The frequent change of rate results in high sweep efficiency. The optimal injection scheme, when compared with constant injection, can improve sweep efficiency by 20-35%. InterpretationDispersion plays a key role in the mitigation of VF in periodic displacement rates. It enhances the uniform mixing of two fluids in injection stage in any period, while it can more effectively attenuate VF instabilities through the following extraction stage. Fast switch of injection and extraction can mitigate flow instability once it develops. ConclusionThis finding is very novel and significant as it is the first time to control VF instability in porous media without any additional cost. It shows great potential for EOR at zero cost.

  18. Vitamin A determination in milk samples based on the luminol-periodate chemiluminescence system.

    PubMed

    Rishi, Lubna; Yaqoob, Mohammad; Waseem, Amir; Nabi, Abdul

    2014-01-01

    A simple and rapid flow injection (FI) method for the determination of retinyl acetate is reported based on its enhancing effect on the luminol-periodate chemiluminescence (CL) system in an alkaline medium. The detection limit (3s×blank) was 8.0×10⁻⁸ mol L⁻¹, with an injection throughput of 90 h⁻¹. The method allows linear increase of CL intensity over the retinyl acetate concentration range of 1.0-100×10⁻⁷ mol L⁻¹ (R²=0.9996) with relative standard deviations of 2.4% (n=10) for 5.0×10⁻⁷ mol L⁻¹. The key chemical and physical variables (reagent concentrations, flow rates, sample volume, and photomultiplier tube (PMT) voltage) were optimized and potential interferences were investigated. The method was successfully applied to human milk, fresh cow's milk and infant milk-based formulas and the results were in good agreement with the previously reported HPLC method. A brief discussion on the possible CL reaction mechanism is also presented.

  19. Quality evaluation of Guan-Xin-Ning injection based on fingerprint analysis and simultaneous separation and determination of seven bioactive constituents by capillary electrophoresis.

    PubMed

    Xu, Liying; Chang, Ruimiao; Chen, Meng; Li, Lou; Huang, Yayun; Zhang, Hongfen; Chen, Anjia

    2017-12-01

    The purpose of this study was to develop a comprehensive, rapid and practical capillary electrophoresis (CE) method for quality control (QC) of Guan-Xin-Ning (GXN) injection based on fingerprint analysis and simultaneous separation and determination of seven constituents. In fingerprint analysis, a capillary zone electrophoresis (CZE) method with a running buffer of 30 mM borate solution (pH 9.3) was established. Meanwhile, ten batches of samples were used to establish the fingerprint electropherogram and 34 common peaks were obtained within 20 min. The RSD of relative migration times (RMT) and relative peak areas (RPA) were less than 5%. In order to further evaluate the quality of GXN injection, a micellar electrokinetic chromatography (MEKC) method was developed for simultaneous separation and determination of bioactive constituents. Seven components reached baseline separation with a running buffer containing 35 mM SDS and 45 mM borate solution (pH 9.3). A good linearity was obtained with correlation coefficients from 0.9906 to 0.9997. The LOD and LOQ ranged from 0.12 to 1.50 μg/mL and from 0.40 to 4.90 μg/mL, respectively. The recoveries ranged between 99.0 and 104.4%. Therefore, it was concluded that the proposed method can be used for full-scale quality analysis of GXN injection. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Environmental and economic comparisons of manure application methods in farming systems.

    PubMed

    Rotz, C A; Kleinman, P J A; Dell, C J; Veith, T L; Beegle, D B

    2011-01-01

    Alternative methods for applying livestock manure to no-till soils involve environmental and economic trade-offs. A process-level farm simulation model (Integrated Farm System Model) was used to evaluate methods for applying liquid dairy (Bos taurus L.) and swine (Sus scrofa L.) manure, including no application, broadcast spreading with and without incorporation by tillage, band application with soil aeration, and shallow disk injection. The model predicted ammonia emissions, nitrate leaching, and phosphorus (P) runoff losses similar to those measured over 4 yr of field trials. Each application method was simulated over 25 yr of weather on three Pennsylvania farms. On a swine and cow-calf beef operation under grass production, shallow disk injection increased profit by $340 yr(-1) while reducing ammonia nitrogen and soluble P losses by 48 and 70%, respectively. On a corn (Zea mays L.)-and-grass-based grazing dairy farm, shallow disk injection reduced ammonia loss by 21% and soluble P loss by 76% with little impact on farm profit. Incorporation by tillage and band application with aeration provided less environmental benefit with a net decrease in farm profit. On a large corn-and-alfalfa (Medicago sativa L.)-based dairy farm where manure nutrients were available in excess of crop needs, incorporation methods were not economically beneficial, but they provided environmental benefits with relatively low annual net costs ($13 to $18 cow). In all farming systems, shallow disk injection provided the greatest environmental benefit at the least cost or greatest profit for the producer. With these results, producers are better informed when selecting manure application equipment.

  1. Validated flow-injection method for rapid aluminium determination in anti-perspirants.

    PubMed

    López-Gonzálvez, A; Ruiz, M A; Barbas, C

    2008-09-29

    A flow-injection (FI) method for the rapid determination of aluminium in anti-perspirants has been developed. The method is based on the spectrophotometric detection at 535nm of the complex formed between Al ions and the chromogenic reagent eriochrome cyanine R. Both the batch and FI methods were validated by checking the parameters included in the ISO-3543-1 regulation. Variables involved in the FI method were optimized by using appropriate statistical tools. The method does not exhibit interference from other substances present in anti-perspirants and it shows a high precision with a R.S.D. value (n=6) of 0.9%. Moreover, the accuracy of the method was evaluated by comparison with a back complexometric titration method, which is currently used for routine analysis in pharmaceutical laboratories. The Student's t-test showed that the results obtained by both methods were not significantly different for a significance level of 95%. A response time of 12s and a sample analysis time, by performing triplicate injections, of 60s were achieved. The analytical figures of merit make the method highly appropriate to substitute the time-consuming complexometric method for this kind of analysis.

  2. Injection practice in Kaski district, Western Nepal: a community perspective.

    PubMed

    Gyawali, Sudesh; Rathore, Devendra Singh; Shankar, Pathiyil Ravi; Kumar, Vikash K C; Maskey, Manisha; Jha, Nisha

    2015-04-29

    Previous studies have shown that unsafe injection practice is a major public health problem in Nepal but did not quantify the problem. The present community-based study was planned to: 1) quantify injection usage, 2) identify injection providers, 3) explore differences, if any, in injection usage and injection providers, and 4) study and compare people's knowledge and perception about injections between the urban and rural areas of Kaski district. A descriptive, cross-sectional mixed-methods study was conducted from July to November 2012, using a questionnaire based survey and focus group discussions (FGDs). A semi-structured questionnaire advocated by the World Health Organization was modified and administered to household heads and injection receivers in selected households and the FGDs were conducted using a topic guide. The district was divided into urban and rural areas and 300 households from each area were selected. Twenty FGDs were held. In 218 households (36.33%) [99 in urban and 119 in rural] one or more members received at least one injection. During the three month recall period, 258 subjects (10.44%) reported receiving injection(s) with a median of two injections. The average number of injections per person per year was calculated to be 2.37. Health care workers (34.8%), staff of medical dispensaries (37.7%), physicians (25.2%), and traditional healers (2.3%) were consulted by the respondents for their basic health care needs and for injections. Compared to urban respondents, more rural respondents preferred injections for fever (p < 0.001). People preferred injections due to injections being perceived by them as being powerful, fast-acting, and longer lasting than oral pills. More than 82% of respondents were aware of, and named, at least one disease transmitted by using unsterile syringes during injection administration or when syringes are shared between people. Less preference for injections and high awareness about the association between injections and injection-borne infections among the general population is encouraging for safe injection practice. However, respondents were not aware of the importance of having qualified injection providers for safe injections and were receiving injections from unqualified personnel.

  3. High pressure common rail injection system modeling and control.

    PubMed

    Wang, H P; Zheng, D; Tian, Y

    2016-07-01

    In this paper modeling and common-rail pressure control of high pressure common rail injection system (HPCRIS) is presented. The proposed mathematical model of high pressure common rail injection system which contains three sub-systems: high pressure pump sub-model, common rail sub-model and injector sub-model is a relative complicated nonlinear system. The mathematical model is validated by the software Matlab and a virtual detailed simulation environment. For the considered HPCRIS, an effective model free controller which is called Extended State Observer - based intelligent Proportional Integral (ESO-based iPI) controller is designed. And this proposed method is composed mainly of the referred ESO observer, and a time delay estimation based iPI controller. Finally, to demonstrate the performances of the proposed controller, the proposed ESO-based iPI controller is compared with a conventional PID controller and ADRC. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  4. A novel method for the induction of experimental glaucoma using magnetic microspheres.

    PubMed

    Samsel, Paulina A; Kisiswa, Lilian; Erichsen, Jonathan T; Cross, Stephen D; Morgan, James E

    2011-03-25

    The development of a method for the sustained elevation of intraocular pressure in experimental glaucoma based on the anterior chamber injection of paramagnetic microbeads. Unilateral glaucoma was induced in adult male Norwegian Brown rats by the injection of paramagnetic polystyrene microspheres. A handheld 0.45 Tesla magnet was used to draw the beads into the iridocorneal angle to impede aqueous drainage via the trabecular meshwork. Elevated intraocular pressures (IOPs) were induced in 61 rats, resulting in a mean elevation of 5.8 mm Hg ± 1.0 (SEM) relative to the contralateral control eye. The mean duration of sustained IOP elevation (defined as >5 mm Hg relative to the control eye for at least 7 consecutive days) after a single injection was 12.8 days ± 0.9 (SEM, maximum duration 27 days). In all eyes, the visual axis remained clear from the time of injection, with minimal inflammation after injection. Retinal ganglion cell loss was determined in 21 animals (mean integral IOP, 194.5 mm Hg days ± 87.5 [SEM]) as 36.4% ± 2.4 (SEM) compared with the contralateral, untreated eye. The use of paramagnetic microbeads for the occlusion of the iridocorneal angle produces a sustained elevation of IOP with fewer injections and avoids the risk of visual axis occlusion. It represents a simple and effective method for the induction of experimental glaucoma.

  5. Development and Validation of a Fast Procedure to Analyze Amoxicillin in River Waters by Direct-Injection LC-MS/MS

    ERIC Educational Resources Information Center

    Homem, Vera; Alves, Arminda; Santos, Lu´cia

    2014-01-01

    A laboratory application with a strong component in analytical chemistry was designed for undergraduate students, in order to introduce a current problem in the environmental science field, the water contamination by antibiotics. Therefore, a simple and rapid method based on direct injection and high performance liquid chromatography-tandem mass…

  6. Effect of deep injection on field-scale emissions of 1,3-dichloropropene and chloropicrin from bare soil

    NASA Astrophysics Data System (ADS)

    Yates, S. R.; Ashworth, D. J.; Zheng, W.; Knuteson, J.; van Wesenbeeck, I. J.

    2016-07-01

    Fumigating soil is important for the production of many high-value vegetable, fruit, and tree crops, but fumigants are toxic pesticides with relatively high volatility, which can lead to significant atmospheric emissions. A field experiment was conducted to measure emissions and subsurface diffusion of a mixture of 1,3-dichloropropene (1,3-D) and chloropicrin after shank injection to bare soil at 61 cm depth (i.e., deep injection). Three on-field methods, the aerodynamic (ADM), integrated horizontal flux (IHF), and theoretical profile shape (TPS) methods, were used to obtain fumigant flux density and cumulative emission values. Two air dispersion models (CALPUFF and ISCST3) were also used to back-calculate the flux density using air concentration measurements surrounding the fumigated field. Emissions were continuously measured for 16 days and the daily peak emission rates for the five methods ranged from 13 to 33 μg m-2 s-1 for 1,3-D and 0.22-3.2 μg m-2 s-1 for chloropicrin. Total 1,3-D mass lost to the atmosphere was approximately 23-41 kg ha-1, or 15-27% of the applied active ingredient and total mass loss of chloropicrin was <2%. Based on the five methods, deep injection reduced total emissions by approximately 2-24% compared to standard fumigation practices where fumigant injection is at 46 cm depth. Given the relatively wide range in emission-reduction percentages, a fumigant diffusion model was used to predict the percentage reduction in emissions by injecting at 61 cm, which yielded a 21% reduction in emissions. Significant reductions in emissions of 1,3-D and chloropicrin are possible by injecting soil fumigants deeper in soil.

  7. Identification of protein components and quantitative immunoassay for SEC2 in staphylococcin injection.

    PubMed

    Ding, Ding; Huang, Peng; Sun, Hongying; Xue, Qiao; Pan, Yingqiu; Chen, Shuqing

    2009-08-15

    In China, staphylococcin injection has been commonly used in combined cancer therapy to enhance the systemic immune response and reduce the toxicities associated with chemotherapy or radiation therapy in the last decade. It is claimed that the main effective component is staphylococcal enterotoxin C2 (SEC2). However, no standard method based on the concentration of SEC2 has been established for quality control of the injection products. In this study, a sensitive and reliable biotin-streptavidin-ELISA (BS-ELISA) method was established for detection and quantification of SEC2. In addition, 1-D SDS-PAGE coupled with nano-LC-MS/MS was performed to identify the protein components in the injection products from one manufacturing company. The results of the BS-ELISA showed that SEC2 only accounted for less than 0.1% of the total protein in the injection products, and the nano-LC-MS/MS results showed that fifty-five proteins of Staphylococcus aureus were confidently identified in the injection solution. Seventeen out of these proteins, including SEC2, were well-known virulence factors. In addition, eighteen proteins of other Gram-positive bacteria were also confidently identified. Thus, the results indicated that SEC2 is of very low concentration in the injection products and the process of the injection preparation should be improved for health and safety consideration.

  8. Detection of Peptide-Based Nanoparticles in Blood Plasma by ELISA

    PubMed Central

    Bode, Gerard H.; Pickl, Karin E.; Sanchez-Purrà, Maria; Albaiges, Berta; Borrós, Salvador; Pötgens, Andy J. G.; Schmitz, Christoph; Sinner, Frank M.; Losen, Mario; Steinbusch, Harry W. M.; Frank, Hans-Georg; Martinez-Martinez, Pilar

    2015-01-01

    Aims The aim of the current study was to develop a method to detect peptide-linked nanoparticles in blood plasma. Materials & Methods A convenient enzyme linked immunosorbent assay (ELISA) was developed for the detection of peptides functionalized with biotin and fluorescein groups. As a proof of principle, polymerized pentafluorophenyl methacrylate nanoparticles linked to biotin-carboxyfluorescein labeled peptides were intravenously injected in Wistar rats. Serial blood plasma samples were analyzed by ELISA and by liquid chromatography mass spectrometry (LC/MS) technology. Results The ELISA based method for the detection of FITC labeled peptides had a detection limit of 1 ng/mL. We were able to accurately measure peptides bound to pentafluorophenyl methacrylate nanoparticles in blood plasma of rats, and similar results were obtained by LC/MS. Conclusions We detected FITC-labeled peptides on pentafluorophenyl methacrylate nanoparticles after injection in vivo. This method can be extended to detect nanoparticles with different chemical compositions. PMID:25996618

  9. Determination of somatropin charged variants by capillary zone electrophoresis - optimisation, verification and implementation of the European pharmacopoeia method.

    PubMed

    Storms, S M; Feltus, A; Barker, A R; Joly, M-A; Girard, M

    2009-03-01

    Measurement of somatropin charged variants by isoelectric focusing was replaced with capillary zone electrophoresis in the January 2006 European Pharmacopoeia Supplement 5.3, based on results from an interlaboratory collaborative study. Due to incompatibilities and method-robustness issues encountered prior to verification, a number of method parameters required optimisation. As the use of a diode array detector at 195 nm or 200 nm led to a loss of resolution, a variable wavelength detector using a 200 nm filter was employed. Improved injection repeatability was obtained by increasing the injection time and pressure, and changing the sample diluent from water to running buffer. Finally, definition of capillary pre-treatment and rinse procedures resulted in more consistent separations over time. Method verification data are presented demonstrating linearity, specificity, repeatability, intermediate precision, limit of quantitation, sample stability, solution stability, and robustness. Based on these experiments, several modifications to the current method have been recommended and incorporated into the European Pharmacopoeia to help improve method performance across laboratories globally.

  10. Injection laryngoplasty as miniinvasive office-based surgery in patients with unilateral vocal fold paralysis – voice quality outcomes

    PubMed Central

    Sielska-Badurek, Ewelina M.; Jędra, Katarzyna; Rzepakowska, Anna; Osuch-Wójcikiewicz, Ewa; Niemczyk, Kazimierz

    2017-01-01

    Introduction Injection laryngoplasty (glottis augmentation) is the preferred method in surgical management of unilateral vocal fold paralysis (UVFP). Traditionally, these procedures are performed in the operating room. Nowadays, however, these procedures have moved into the office. Aim To evaluate the voice quality after transoral injection laryngoplasty under local anaesthesia in patients with unilateral vocal fold paralysis. Material and methods Fourteen subjects (5 women and 9 men) with unilateral vocal fold paresis (9 with right vocal fold paresis and 5 with left vocal fold paresis) were included in the study. The mean age of the group was 57.8 ±19.0 years (32–83 years). All of the injection laryngoplasties were performed transorally, under local anaesthesia. The injection material was calcium hydroxylapatite. Before and 1, 3 and 6 months after the procedure the following variables were evaluated: voice perception, videostroboscopy, acoustic analysis, aerodynamic evaluation, and the subjective rating of the voice quality by the patient. Results After injection laryngoplasty, complete glottal closure was achieved or there was a significant improvement in the glottal closure of each subject. We noted great improvement in the post-injection objective and subjective voice outcomes and patients reported improvement in the voice-related quality of life. Conclusions The transoral approach for injection laryngoplasty under local anaesthesia is an effective and safe way to treat incomplete glottal closure in patients with UVFP. The transoral approach is an efficient alternative to other surgical techniques used for vocal fold injection. PMID:29062449

  11. A novel cell weighing method based on the minimum immobilization pressure for biological applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Qili; Institute of Robotics and Automatic Information System, Nankai University, Tianjin 300071; Shirinzadeh, Bijan

    2015-07-28

    A novel weighing method for cells with spherical and other regular shapes is proposed in this paper. In this method, the relationship between the cell mass and the minimum aspiration pressure to immobilize the cell (referred to as minimum immobilization pressure) is derived for the first time according to static theory. Based on this relationship, a robotic cell weighing process is established using a traditional micro-injection system. Experimental results on porcine oocytes demonstrate that the proposed method is able to weigh cells at an average speed of 16.3 s/cell and with a success rate of more than 90%. The derived cellmore » mass and density are in accordance with those reported in other published results. The experimental results also demonstrated that this method is able to detect less than 1% variation of the porcine oocyte mass quantitatively. It can be conducted by a pair of traditional micropipettes and a commercial pneumatic micro-injection system, and is expected to perform robotic operation on batch cells. At present, the minimum resolution of the proposed method for measuring the cell mass can be 1.25 × 10{sup −15 }kg. Above advantages make it very appropriate for quantifying the amount of the materials injected into or moved out of the cells in the biological applications, such as nuclear enucleations and embryo microinjections.« less

  12. Nano-fabricated perpendicular magnetic anisotropy electrodes for lateral spin valves and observation of Nernst-Ettingshausen related signals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chejanovsky, N.; Sharoni, A., E-mail: amos.sharoni@biu.ac.il

    2014-08-21

    Lateral spin valves (LSVs) are efficient structures for characterizing spin currents in spintronics devices. Most LSVs are based on ferromagnetic (FM) electrodes for spin-injection and detection. While there are advantages for using perpendicular magnetic anisotropy (PMA) FM, e.g., stability to nano-scaling, these have almost not been studied. This is mainly due to difficulties in fabricating PMA FMs in a lateral geometry. We present here an efficient method, based on ion-milling through an AlN mask, for fabrication of LSVs with multi-layered PMA FMs such as Co/Pd and Co/Ni. We demonstrate, using standard permalloy FMs, that the method enables efficient spin injection.more » We show the multi-layer electrodes retain their PMA properties as well as spin injection and detection in PMA LSVs. In addition, we find a large asymmetric voltage signal which increases with current. We attribute this to a Nernst-Ettingshausen effect caused by local Joule heating and the perpendicular magnetic easy axis.« less

  13. Chemiluminescence determination of ferulic acid by flow-injection analysis using cerium(IV) sensitized by rhodamine 6G.

    PubMed

    Wang, Ju Peng; Li, Nian Bing; Luo, Hong Qun

    2008-11-01

    A simple, sensitive and rapid flow-injection chemiluminescence method has been developed for the determination of ferulic acid based on the chemiluminescence reaction of ferulic acid with rhodamine 6G and ceric sulfate in sulphuric acid medium. Strong chemiluminescence signal was observed when ferulic acid was injected into the acidic ceric sulfate solution in a flow-cell. The present method allowed the determination of ferulic acid in the concentration range of 8.0 x 10(-6) to 1.0 x 10(-4) mol l(-1) and the detection limit for ferulic acid was 8.7 x 10(-9) mol l(-1). The relative standard deviation was 2.4% for 10 replicate analyses of 1.0 x 10(-5) mol l(-1) ferulic acid. The proposed method was applied to the determination of ferulic acid in Taita Beauty Essence samples with satisfactory results.

  14. Chemiluminescence determination of ferulic acid by flow-injection analysis using cerium(IV) sensitized by rhodamine 6G

    NASA Astrophysics Data System (ADS)

    Wang, Ju Peng; Li, Nian Bing; Luo, Hong Qun

    2008-11-01

    A simple, sensitive and rapid flow-injection chemiluminescence method has been developed for the determination of ferulic acid based on the chemiluminescence reaction of ferulic acid with rhodamine 6G and ceric sulfate in sulphuric acid medium. Strong chemiluminescence signal was observed when ferulic acid was injected into the acidic ceric sulfate solution in a flow-cell. The present method allowed the determination of ferulic acid in the concentration range of 8.0 × 10 -6 to 1.0 × 10 -4 mol l -1 and the detection limit for ferulic acid was 8.7 × 10 -9 mol l -1. The relative standard deviation was 2.4% for 10 replicate analyses of 1.0 × 10 -5 mol l -1 ferulic acid. The proposed method was applied to the determination of ferulic acid in Taita Beauty Essence samples with satisfactory results.

  15. Light propagation in the micro-size capillary injected by high temperature liquid

    NASA Astrophysics Data System (ADS)

    Li, Yan-jun; Li, Edward; Xiao, Hai

    2016-11-01

    The high temperature liquid is injected into the micro-size capillary and its light propagation behavior is investigated. We focus on two different liquid pumping methods. The first method can pump the high temperature liquid tin into the micro-size capillary by using a high pressure difference system. After pumping, a single mode fiber (SMF) connected with the optical carrier based microwave interferometry (OCMI) system is used to measure different liquid tin levels in the micro-size capillary. The second method can pump the room temperature engine oil into the capillary by using a syringe pump. This method can avoid the air bubbles when the liquids are pumped into the capillary.

  16. Isolation and characterization of Conohyal-P1, a hyaluronidase from the injected venom of Conus purpurascens.

    PubMed

    Möller, Carolina; Clark, Evan; Safavi-Hemami, Helena; DeCaprio, Anthony; Marí, Frank

    2017-07-05

    Hyaluronidases are ubiquitous enzymes commonly found in venom and their main function is to degrade hyaluran, which is the major glycosaminoglycan of the extracellular matrix in animal tissues. Here we describe the purification and characterization of a 60kDa hyaluronidase found in the injected venom from Conus purpurascens, Conohyal-P1. Using a combined strategy based on transcriptomic and proteomic analysis, we determined the Conohyal-P1 sequence. Conohyal-P1 has conserved consensus catalytic and positioning domain residues characteristic of hyaluronidases and a C-terminus EGF-like domain. Additionally, the enzyme is expressed as a mixture of glycosylated isoforms at five asparagine sites. The activity of the native Conohyal-P1 was assess MS-based methods and confirmed by classical turbidimetric methods. The MS-based assay is particularly sensitive and provides the first detailed analysis of a venom hyaluronidase activity monitored with this method. The discovery of new hyaluronidases and the development of techniques to evaluate their performance can advance several therapeutic procedures, as these enzymes are widely used for enhanced drug delivery applications. Cone snail venom is a remarkable source of therapeutically important molecules, as is the case of conotoxins, which have undergone extensive clinical trials for several applications. In addition to the conotoxins, a large array of proteins have been reported in the venom of several species of cone snails, including enzymes that were found in dissected and injected Conus venom. Here we describe the isolation and characterization of the hyaluronidase Conohyal-P1 from the injected venom of C. purpurascens. We employed a combined transcriptomic and proteomic analysis to obtain the full sequence of this hyaluronidase. The activity of Conohyal-P1 was assessed by a mass spectrometry-based method, which provide the first detailed venom hyaluronidase activity analysis monitored by mass spectrometry allowing the visualization of the substrate degradation by the enzyme. Published by Elsevier B.V.

  17. Determination of chloride in admixtures and aggregates for cement by a simple flow injection potentiometric system.

    PubMed

    Junsomboon, Jaroon; Jakmunee, Jaroon

    2008-07-15

    A simple flow injection system using three 3-way solenoid valves as an electric control injection valve and with a simple home-made chloride ion selective electrode based on Ag/AgCl wire as a sensor for determination of water soluble chloride in admixtures and aggregates for cement has been developed. A liquid sample or an extract was injected into a water carrier stream which was then merged with 0.1M KNO(3) stream and flowed through a flow cell where the solution will be in contact with the sensor, producing a potential change recorded as a peak. A calibration graph in range of 10-100 mg L(-1) was obtained with a detection limit of 2 mg L(-1). Relative standard deviations for 7 replicates injecting of 20, 60 and 90 mg L(-1) chloride solutions were 1.0, 1.2 and 0.6%, respectively. Sample throughput of 60 h(-1) was achieved with the consumption of 1 mL each of electrolyte solution and water carrier. The developed method was validated by the British Standard methods.

  18. Generation of Transgenic Pigs by Cytoplasmic Injection of piggyBac Transposase-Based pmGENIE-3 Plasmids1

    PubMed Central

    Li, Zicong; Zeng, Fang; Meng, Fanming; Xu, Zhiqian; Zhang, Xianwei; Huang, Xiaoling; Tang, Fei; Gao, Wenchao; Shi, Junsong; He, Xiaoyan; Liu, Dewu; Wang, Chong; Urschitz, Johann; Moisyadi, Stefan; Wu, Zhenfang

    2014-01-01

    ABSTRACT The process of transgenesis involves the introduction of a foreign gene, the transgene, into the genome of an animal. Gene transfer by pronuclear microinjection (PNI) is the predominant method used to produce transgenic animals. However, this technique does not always result in germline transgenic offspring and has a low success rate for livestock. Alternate approaches, such as somatic cell nuclear transfer using transgenic fibroblasts, do not show an increase in efficiency compared to PNI, while viral-based transgenesis is hampered by issues regarding transgene size and biosafety considerations. We have recently described highly successful transgenesis experiments with mice using a piggyBac transposase-based vector, pmhyGENIE-3. This construct, a single and self-inactivating plasmid, contains all the transpositional elements necessary for successful gene transfer. In this series of experiments, our laboratories have implemented cytoplasmic injection (CTI) of pmGENIE-3 for transgene delivery into in vivo-fertilized pig zygotes. More than 8.00% of the injected embryos developed into transgenic animals containing monogenic and often single transgenes in their genome. However, the CTI technique was unsuccessful during the injection of in vitro-fertilized pig zygotes. In summary, here we have described a method that is not only easy to implement, but also demonstrated the highest efficiency rate for nonviral livestock transgenesis. PMID:24671876

  19. Single Cell Transfection through Precise Microinjection with Quantitatively Controlled Injection Volumes

    NASA Astrophysics Data System (ADS)

    Chow, Yu Ting; Chen, Shuxun; Wang, Ran; Liu, Chichi; Kong, Chi-Wing; Li, Ronald A.; Cheng, Shuk Han; Sun, Dong

    2016-04-01

    Cell transfection is a technique wherein foreign genetic molecules are delivered into cells. To elucidate distinct responses during cell genetic modification, methods to achieve transfection at the single-cell level are of great value. Herein, we developed an automated micropipette-based quantitative microinjection technology that can deliver precise amounts of materials into cells. The developed microinjection system achieved precise single-cell microinjection by pre-patterning cells in an array and controlling the amount of substance delivered based on injection pressure and time. The precision of the proposed injection technique was examined by comparing the fluorescence intensities of fluorescent dye droplets with a standard concentration and water droplets with a known injection amount of the dye in oil. Injection of synthetic modified mRNA (modRNA) encoding green fluorescence proteins or a cocktail of plasmids encoding green and red fluorescence proteins into human foreskin fibroblast cells demonstrated that the resulting green fluorescence intensity or green/red fluorescence intensity ratio were well correlated with the amount of genetic material injected into the cells. Single-cell transfection via the developed microinjection technique will be of particular use in cases where cell transfection is challenging and genetically modified of selected cells are desired.

  20. Single Cell Transfection through Precise Microinjection with Quantitatively Controlled Injection Volumes.

    PubMed

    Chow, Yu Ting; Chen, Shuxun; Wang, Ran; Liu, Chichi; Kong, Chi-Wing; Li, Ronald A; Cheng, Shuk Han; Sun, Dong

    2016-04-12

    Cell transfection is a technique wherein foreign genetic molecules are delivered into cells. To elucidate distinct responses during cell genetic modification, methods to achieve transfection at the single-cell level are of great value. Herein, we developed an automated micropipette-based quantitative microinjection technology that can deliver precise amounts of materials into cells. The developed microinjection system achieved precise single-cell microinjection by pre-patterning cells in an array and controlling the amount of substance delivered based on injection pressure and time. The precision of the proposed injection technique was examined by comparing the fluorescence intensities of fluorescent dye droplets with a standard concentration and water droplets with a known injection amount of the dye in oil. Injection of synthetic modified mRNA (modRNA) encoding green fluorescence proteins or a cocktail of plasmids encoding green and red fluorescence proteins into human foreskin fibroblast cells demonstrated that the resulting green fluorescence intensity or green/red fluorescence intensity ratio were well correlated with the amount of genetic material injected into the cells. Single-cell transfection via the developed microinjection technique will be of particular use in cases where cell transfection is challenging and genetically modified of selected cells are desired.

  1. Physical Therapy for an Adult with Chronic Stroke after Botulinum Toxin Injection for Spasticity: A Case Report

    PubMed Central

    Phadke, Chetan P.; Ismail, Farooq; Boulias, Chris

    2015-01-01

    ABSTRACT Purpose: In this case report, we describe the type and duration of a physical therapy and botulinum toxin type A (BoNTA) intervention directed at lower limb spasticity and the gait and balance improvement in a patient post-stroke. Treatment of focal spasticity with BoNTA intramuscular injections combined with physical therapy is recommended by rehabilitation experts. However, the optimal type and duration of physical therapy intervention to optimize any functional gains that follow chemodenervation induced by BoNTA has not been established. Method: One individual with chronic stroke who received BoNTA injections for upper and lower extremity spasticity was included. Physical therapy intervention consisted of 45- to 60-min sessions twice weekly for 12 weeks, based on the Bobath–neurodevelopmental therapy approach, and an activity-based home program. Results: After BoNTA injections and physical therapy, the patient made clinically significant improvements in balance and gait speed and became more independent with his ambulation. Conclusions: This case report demonstrates that physical therapy after BoNTA injections can result in significant functional improvements for individuals with spasticity after chronic stroke that may not be possible with BoNTA injections alone. PMID:25931655

  2. A redesigned follitropin alfa pen injector for infertility: results of a market research study

    PubMed Central

    Abbotts, Carole; Salgado-Braga, Cristiana; Audibert-Gros, Céline

    2011-01-01

    Background: The purpose of this study was to evaluate patient-learning and nurse-teaching experiences when using a redesigned prefilled, ready-to-use follitropin alfa pen injector. Methods: Seventy-three UK women of reproductive age either administering daily treatment with self-injectable gonadotropins or about to start gonadotropin treatment for infertility (aged 24–47 years; 53 self-injection-experienced and 20 self-injection-naïve) and 28 nurses from UK infertility clinics were recruited for the study. Following instruction, patients and nurses used the redesigned follitropin alfa pen to inject water into an orange and completed questionnaires to evaluate their experiences with the pen immediately after the simulated injections. Results: Most (88%, n = 64) patients found it easy to learn how to use the pen. Among injection-experienced patients, 66% (n = 35) agreed that the redesigned pen was easier to learn to use compared with their current method and 70% (n = 37) also said they would prefer its use over current devices for all injectable fertility medications. All nurses considered the redesigned pen easy to learn and believed it would be easy to teach patients how to use. Eighty-six percent (n = 24) of the nurses thought it was easy to teach patients to determine the remaining dose to be dialed and injected in a second pen if the initial dose was incomplete. Compared with other injection devices, 96% (n = 27) thought it was “much easier” to “as easy” to teach patients to use the redesigned pen. Based on ease of teaching, 68% (n = 19) of nurses would choose to teach the pen in preference to any other injection method. Almost all (93%, n = 26) nurses considered that having the same pen format for a range of injectable gonadotropins would facilitate teaching and learning self-injection. Conclusion: In this market research study with infertile patients and infertility nurses, the redesigned follitropin alfa pen was perceived as easy to learn, easy to teach how to use, and well accepted. PMID:21792303

  3. [Study for the revision of analytical method for tris (2,3-dibromopropyl) phosphate with restriction in textiles].

    PubMed

    Mimura, Mayumi; Nakashima, Harunobu; Yoshida, Jin; Yoshida, Toshiaki; Kawakami, Tsuyoshi; Isama, Kazuo

    2014-01-01

    The official analytical method for tris(2,3-dibromopropyl)phosphate (TDBPP), which is banned from use in textile products by the "Act on Control of Household Products Containing Harmful Substances", requires revision. This study examined an analytical method for TDBPP by GC/MS using a capillary column. Thermal decomposition of TDBPP was observed by GC/MS measurement using capillary column, unlike in the case of gas chromatography/flame photometric detector (GC/FPD) measurement based on a direct injection method using a capillary megabore column. A quadratic curve, Y=2572X(1.416), was obtained for the calibration curve of GC/FPD in the concentration range 2.0-100 μg/mL. The detection limit was 1.0 μg/mL under S/N=3. The reproducibility for repetitive injections was satisfactory. A pretreatment method was established using methanol extraction, followed by liquid-liquid partition and purification with a florisil cartridge column. The recovery rate of this method was ~100%. TDBPP was not detected in any of the five commercial products that this study analyzed. To understand the cause of TDBPP decomposition during GC/MS (electron ionization; EI) measurement using capillary column, GC/MS (chemical ionization; CI), GC/FPD, and gas chromatography/flame ionization detector (GC/FID) measurements were conducted. It was suggested that TDBPP might thermally decompose both during GC injection, especially through a splitless injection method, and in the column or ion sources. To attempt GC/MS measurement, an injection part comprising quartz liner was used and the column length was halved (15 m); thus, only one peak could be obtained.

  4. [Quantitative evaluation of Gd-EOB-DTPA uptake in phantom study for liver MRI].

    PubMed

    Hayashi, Norio; Miyati, Tosiaki; Koda, Wataru; Suzuki, Masayuki; Sanada, Shigeru; Ohno, Naoki; Hamaguchi, Takashi; Matsuura, Yukihiro; Kawahara, Kazuhiro; Yamamoto, Tomoyuki; Matsui, Osamu

    2010-05-20

    Gd-EOB-DTPA is a new liver specific MRI contrast media. In the hepatobiliary phase, contrast media is trapped in normal liver tissue, a normal liver shows high intensity, tumor/liver contrast becomes high, and diagnostic ability improves. In order to indicate the degree of uptake of the contrast media, the enhancement ratio (ER) is calculated. The ER is obtained by calculating (signal intensity (SI) after injection-SI before injection) / SI before injection. However, because there is no linearity between contrast media concentration and SI, ER is not correctly estimated by this method. We discuss a method of measuring ER based on SI and T(1) values using the phantom. We used a column phantom, with an internal diameter of 3 cm, that was filled with Gd-EOB-DTPA diluted solution. Moreover, measurement of the T(1) value by the IR method was also performed. The ER measuring method of this technique consists of the following three components: 1) Measurement of ER based on differences in 1/T(1) values using the variable flip angle (FA) method, 2) Measurement of differences in SI, and 3) Measurement of differences in 1/T(1) values using the IR method. ER values calculated by these three methods were compared. In measurement made using the variable FA method and the IR method, linearity was found between contrast media concentration and ER. On the other hand, linearity was not found between contrast media concentration and SI. For calculation of ER using Gd-EOB-DTPA, a more correct ER is obtained by measuring the T(1) value using the variable FA method.

  5. Survey of intravitreal injection techniques among retina specialists in Israel

    PubMed Central

    Segal, Ori; Segal-Trivitz, Yael; Nemet, Arie Y; Geffen, Noa; Nesher, Ronit; Mimouni, Michael

    2016-01-01

    Purpose The purpose of this study was to describe antivascular endothelial growth factor intravitreal injection techniques of retinal specialists in order to establish a cornerstone for future practice guidelines. Methods All members of the Israeli Retina Society were contacted by email to complete an anonymous, 19-question, Internet-based survey regarding their intravitreal injection techniques. Results Overall, 66% (52/79) completed the survey. Most (98%) do not instruct patients to discontinue anticoagulant therapy and 92% prescribe treatment for patients in the waiting room. Three quarters wear sterile gloves and prepare the patient in the supine position. A majority (71%) use sterile surgical draping. All respondents apply topical analgesics and a majority (69%) measure the distance from the limbus to the injection site. A minority (21%) displace the conjunctiva prior to injection. A majority of the survey participants use a 30-gauge needle and the most common quadrant for injection is superotemporal (33%). Less than half routinely assess postinjection optic nerve perfusion (44%). A majority (92%) apply prophylactic antibiotics immediately after the injection. Conclusion The majority of retina specialists perform intravitreal injections similarly. However, a relatively large minority performs this procedure differently. Due to the extremely low percentage of complications, it seems as though such differences do not increase the risk. However, more evidence-based medicine, a cornerstone for practice guidelines, is required in order to identify the intravitreal injection techniques that combine safety and efficacy while causing as little discomfort to the patients as possible. PMID:27366050

  6. Method for enhancing selectivity and recovery in the fractional flotation of particles in a flotation column

    DOEpatents

    Klunder, Edgar B [Bethel Park, PA

    2011-08-09

    The method relates to particle separation from a feed stream. The feed stream is injected directly into the froth zone of a vertical flotation column in the presence of a counter-current reflux stream. A froth breaker generates a reflux stream and a concentrate stream, and the reflux stream is injected into the froth zone to mix with the interstitial liquid between bubbles in the froth zone. Counter-current flow between the plurality of bubbles and the interstitial liquid facilitates the attachment of higher hydrophobicity particles to bubble surfaces as lower hydrophobicity particles detach. The height of the feed stream injection and the reflux ratio may be varied in order to optimize the concentrate or tailing stream recoveries desired based on existing operating conditions.

  7. Optimal joule heating of the subsurface

    DOEpatents

    Berryman, James G.; Daily, William D.

    1994-01-01

    A method for simultaneously heating the subsurface and imaging the effects of the heating. This method combines the use of tomographic imaging (electrical resistance tomography or ERT) to image electrical resistivity distribution underground, with joule heating by electrical currents injected in the ground. A potential distribution is established on a series of buried electrodes resulting in energy deposition underground which is a function of the resistivity and injection current density. Measurement of the voltages and currents also permits a tomographic reconstruction of the resistivity distribution. Using this tomographic information, the current injection pattern on the driving electrodes can be adjusted to change the current density distribution and thus optimize the heating. As the heating changes conditions, the applied current pattern can be repeatedly adjusted (based on updated resistivity tomographs) to affect real time control of the heating.

  8. An in situ-forming phospholipid-based phase transition gel prolongs the duration of local anesthesia for ropivacaine with minimal toxicity.

    PubMed

    Li, Hanmei; Liu, Tao; Zhu, Yuxuan; Fu, Qiang; Wu, Wanxia; Deng, Jie; Lan, Li; Shi, Sanjun

    2017-08-01

    An injectable, phospholipid-based phase transition gel (PPTG) has been developed for prolonging the release of ropivacaine (RO) for local anesthesia. PPTG was prepared by mixing phospholipids, medium-chain triglyceride and ethanol. Prior to injection, the PPTG is in a sol state with low viscosity. After subcutaneous injection, the PPTG rapidly forms a gel in situ, which acts as a drug release depot as verified by in vitro release profiles and in vivo pharmacokinetics. Administering RO-PPTG to rats led to a significantly smaller initial burst release than administering RO solution or RO base suspension. Nerve blockade in guinea pigs lasted 3-fold longer after injection of RO-PPTG than after injection of RO solution. RO-PPTG showed good biocompatibility and excellent degradability in vivo. These results suggest that this PPTG-based depot system may be useful for sustained release of local anesthetics to prolong analgesia without causing systemic toxicity. The sustained release of local anesthetics at the surgical site after a single injection is the optimal method to control post-surgical pain. In situ forming implant is an attractive alternative for the sustained release of local anesthetics. However, its practical use is highly limited by certain drawbacks including high viscosity, involved toxic organic solvents and fast drug release. To date, phospholipids-based phase transition gel (PPTG) is emerging for clinical development because of the non-toxicity, biocompatibility and ready availability of phospholipids in body. Thus, we present a novel strategy for sustained release of local anesthetics to control post-surgical pain based on PPTG, which showed a prolonged duration of nerve blockade and excellent biocompatibility. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  9. Deterministic convergence of chaos injection-based gradient method for training feedforward neural networks.

    PubMed

    Zhang, Huisheng; Zhang, Ying; Xu, Dongpo; Liu, Xiaodong

    2015-06-01

    It has been shown that, by adding a chaotic sequence to the weight update during the training of neural networks, the chaos injection-based gradient method (CIBGM) is superior to the standard backpropagation algorithm. This paper presents the theoretical convergence analysis of CIBGM for training feedforward neural networks. We consider both the case of batch learning as well as the case of online learning. Under mild conditions, we prove the weak convergence, i.e., the training error tends to a constant and the gradient of the error function tends to zero. Moreover, the strong convergence of CIBGM is also obtained with the help of an extra condition. The theoretical results are substantiated by a simulation example.

  10. What controls the maximum magnitude of injection-induced earthquakes?

    NASA Astrophysics Data System (ADS)

    Eaton, D. W. S.

    2017-12-01

    Three different approaches for estimation of maximum magnitude are considered here, along with their implications for managing risk. The first approach is based on a deterministic limit for seismic moment proposed by McGarr (1976), which was originally designed for application to mining-induced seismicity. This approach has since been reformulated for earthquakes induced by fluid injection (McGarr, 2014). In essence, this method assumes that the upper limit for seismic moment release is constrained by the pressure-induced stress change. A deterministic limit is given by the product of shear modulus and the net injected fluid volume. This method is based on the assumptions that the medium is fully saturated and in a state of incipient failure. An alternative geometrical approach was proposed by Shapiro et al. (2011), who postulated that the rupture area for an induced earthquake falls entirely within the stimulated volume. This assumption reduces the maximum-magnitude problem to one of estimating the largest potential slip surface area within a given stimulated volume. Finally, van der Elst et al. (2016) proposed that the maximum observed magnitude, statistically speaking, is the expected maximum value for a finite sample drawn from an unbounded Gutenberg-Richter distribution. These three models imply different approaches for risk management. The deterministic method proposed by McGarr (2014) implies that a ceiling on the maximum magnitude can be imposed by limiting the net injected volume, whereas the approach developed by Shapiro et al. (2011) implies that the time-dependent maximum magnitude is governed by the spatial size of the microseismic event cloud. Finally, the sample-size hypothesis of Van der Elst et al. (2016) implies that the best available estimate of the maximum magnitude is based upon observed seismicity rate. The latter two approaches suggest that real-time monitoring is essential for effective management of risk. A reliable estimate of maximum plausible magnitude would clearly be beneficial for quantitative risk assessment of injection-induced seismicity.

  11. Double injection/single detection asymmetric flow injection manifold for spectrophotometric determination of ascorbic acid and uric acid: Selection the optimal conditions by MCDM approach based on different criteria weighting methods.

    PubMed

    Boroumand, Samira; Chamjangali, Mansour Arab; Bagherian, Ghadamali

    2017-03-05

    A simple and sensitive double injection/single detector flow injection analysis (FIA) method is proposed for the simultaneous kinetic determination of ascorbic acid (AA) and uric acid (UA). This method is based upon the difference between the rates of the AA and UA reactions with Fe 3+ in the presence of 1, 10-phenanthroline (phen). The absorbance of Fe 2+ /1, 10-phenanthroline (Fe-phen) complex obtained as the product was measured spectrophotometrically at 510nm. To reach a good accuracy in the differential kinetic determination via the mathematical manipulations of the transient signals, different criteria were considered in the selection of the optimum conditions. The multi criteria decision making (MCDM) approach was applied for the selection of the optimum conditions. The importance weights of the evaluation criteria were determined using the analytic hierarchy process, entropy method, and compromised weighting (CW). The experimental conditions (alternatives) were ranked by the technique for order preference by similarity to an ideal solution. Under the selected optimum conditions, the obtained analytical signals were linear in the ranges of 0.50-5.00 and 0.50-4.00mgL -1 for AA and UA, respectively. The 3σ detection limits were 0.07mgL -1 for AA and 0.12mgL -1 for UA. The relative standard deviations for four replicate determinations of AA and UA were 2.03% and 3.30% respectively. The method was also applied for the analysis of analytes in the blood serum, Vitamine C tablets, and tap water with satisfactory results. Copyright © 2016. Published by Elsevier B.V.

  12. Double injection/single detection asymmetric flow injection manifold for spectrophotometric determination of ascorbic acid and uric acid: Selection the optimal conditions by MCDM approach based on different criteria weighting methods

    NASA Astrophysics Data System (ADS)

    Boroumand, Samira; Chamjangali, Mansour Arab; Bagherian, Ghadamali

    2017-03-01

    A simple and sensitive double injection/single detector flow injection analysis (FIA) method is proposed for the simultaneous kinetic determination of ascorbic acid (AA) and uric acid (UA). This method is based upon the difference between the rates of the AA and UA reactions with Fe3 + in the presence of 1, 10-phenanthroline (phen). The absorbance of Fe2 +/1, 10-phenanthroline (Fe-phen) complex obtained as the product was measured spectrophotometrically at 510 nm. To reach a good accuracy in the differential kinetic determination via the mathematical manipulations of the transient signals, different criteria were considered in the selection of the optimum conditions. The multi criteria decision making (MCDM) approach was applied for the selection of the optimum conditions. The importance weights of the evaluation criteria were determined using the analytic hierarchy process, entropy method, and compromised weighting (CW). The experimental conditions (alternatives) were ranked by the technique for order preference by similarity to an ideal solution. Under the selected optimum conditions, the obtained analytical signals were linear in the ranges of 0.50-5.00 and 0.50-4.00 mg L- 1 for AA and UA, respectively. The 3σ detection limits were 0.07 mg L- 1 for AA and 0.12 mg L- 1 for UA. The relative standard deviations for four replicate determinations of AA and UA were 2.03% and 3.30% respectively. The method was also applied for the analysis of analytes in the blood serum, Vitamine C tablets, and tap water with satisfactory results.

  13. Medical Injection Use Among Adults and Adolescents Aged 15 to 64 Years in Kenya: Results From a National Survey

    PubMed Central

    Kimani, Daniel; Kamau, Rachel; Ssempijja, Victor; Robinson, Katherine; Oluoch, Tom; Njeru, Mercy; Mwangi, Jane; Njogu, David; Kim, Andrea A.

    2016-01-01

    Background Unsafe medical injections remain a potential route of HIV transmission in Kenya. We used data from a national survey in Kenya to study the magnitude of medical injection use, medication preference, and disposal of medical waste in the community. Methods The Kenya AIDS Indicator Survey 2012 was a nationally representative population-based survey. Among participants aged 15–64 years, data were collected regarding medical injections received in the year preceding the interview; blood samples were collected from participants for HIV testing. Results Of the 13,673 participants who answered questions on medical injections, 35.9% [95% confidence interval (CI): 34.5 to 37.3] reported receiving ≥1 injection in the past 12 months and 51.2% (95% CI: 49.7 to 52.8) preferred receiving an injection over a pill. Among those who received an injection from a health care provider, 95.9% (95% CI: 95.2 to 96.7) observed him/her open a new injection pack, and 7.4% (95% CI: 6.4 to 8.4) had seen a used syringe or needle near their home or community in the past 12 months. Men who had received ≥1 injection in the past 12 months (adjusted odds ratio, 3.2; 95% CI: 1.2 to 8.9) and women who had received an injection in the past 12 months, not for family planning purposes (adjusted odds ratio, 2.6; 95% CI: 1.2 to 5.5), were significantly more likely to be HIV infected compared with those who had not received medical injection in the past 12 months. Conclusions Injection preference may contribute to high rates of injections in Kenya. Exposure to unsafe medical waste in the community poses risks for injury and infection. We recommend that community- and facility-based injection safety strategies be integrated in disease prevention programs. PMID:24413041

  14. A multisyringe flow injection Winkler-based spectrophotometric analyzer for in-line monitoring of dissolved oxygen in seawater.

    PubMed

    Horstkotte, Burkhard; Alonso, Juan Carlos; Miró, Manuel; Cerdà, Víctor

    2010-01-15

    An integrated analyzer based on the multisyringe flow injection analysis approach is proposed for the automated determination of dissolved oxygen in seawater. The entire Winkler method including precipitation of manganese(II) hydroxide, fixation of dissolved oxygen, dissolution of the oxidized manganese hydroxide precipitate, and generation of iodine and tri-iodide ion are in-line effected within the flow network. Spectrophotometric quantification of iodine and tri-iodide at the isosbestic wavelength of 466nm renders enhanced method reliability. The calibration function is linear up to 19mgL(-1) dissolved oxygen and an injection frequency of 17 per hour is achieved. The multisyringe system features a highly satisfying signal stability with repeatabilities of 2.2% RSD that make it suitable for continuous determination of dissolved oxygen in seawater. Compared to the manual starch-end-point titrimetric Winkler method and early reported automated systems, concentrations and consumption of reagents and sample are reduced up to hundredfold. The versatility of the multisyringe assembly was exploited in the implementation of an ancillary automatic batch-wise Winkler titrator using a single syringe of the module for accurate titration of the released iodine/tri-iodide with thiosulfate.

  15. Vapor permeation-stepwise injection simultaneous determination of methanol and ethanol in biodiesel with voltammetric detection.

    PubMed

    Shishov, Andrey; Penkova, Anastasia; Zabrodin, Andrey; Nikolaev, Konstantin; Dmitrenko, Maria; Ermakov, Sergey; Bulatov, Andrey

    2016-02-01

    A novel vapor permeation-stepwise injection (VP-SWI) method for the determination of methanol and ethanol in biodiesel samples is discussed. In the current study, stepwise injection analysis was successfully combined with voltammetric detection and vapor permeation. This method is based on the separation of methanol and ethanol from a sample using a vapor permeation module (VPM) with a selective polymer membrane based on poly(phenylene isophtalamide) (PA) containing high amounts of a residual solvent. After the evaporation into the headspace of the VPM, methanol and ethanol were transported, by gas bubbling, through a PA membrane to a mixing chamber equipped with a voltammetric detector. Ethanol was selectively detected at +0.19 V, and both compounds were detected at +1.20 V. Current subtractions (using a correction factor) were used for the selective determination of methanol. A linear range between 0.05 and 0.5% (m/m) was established for each analyte. The limits of detection were estimated at 0.02% (m/m) for ethanol and methanol. The sample throughput was 5 samples h(-1). The method was successfully applied to the analysis of biodiesel samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Injection Force of SoloSTAR® Compared with Other Disposable Insulin Pen Devices at Constant Volume Flow Rates

    PubMed Central

    van der Burg, Thomas

    2011-01-01

    Background Injection force is a particularly important practical aspect of therapy for patients with diabetes, especially those who have dexterity problems. This laboratory-based study compared the injection force of the SoloSTAR® insulin pen (SoloSTAR; sanofi-aventis) versus other available disposable pens at injection speeds based on the delivered volume of insulin released at the needle. Method Four different prefilled disposable pens were tested: SoloSTAR containing insulin glargine; FlexPen® and the Next Generation FlexPen® (NGFP) (Novo Nordisk), both containing insulin detemir; and KwikPen® containing insulin lispro (Eli Lilly). All pens were investigated using the maximum dispense volume for each pen type [80 units (U) for SoloSTAR; 60 U for the other pens], from the free needle tip dispensing into a beaker. Twenty pens of each type were fitted with the recommended needles and tested at two dose speeds (6 and 10 U/s); each pen was tested twice. Results Mean plateau injection force and maximum injection force were consistently lower with SoloSTAR compared with FlexPen, NGFP, and KwikPen at both injection speeds tested. An injection speed of 10 U/s was associated with higher injection force compared with 6 U/s for all the pens tested (p < .001). Conclusions SoloSTAR stands out because of its low injection force, even when compared with newer insulin pen devices such as the KwikPen and NGFP. This may enable patients, especially those with dexterity problems, to administer insulin more easily and improve management of their diabetes. PMID:21303637

  17. Unilateral versus bilateral thyroarytenoid Botulinum toxin injections in adductor spasmodic dysphonia: a prospective study

    PubMed Central

    Upile, Tahwinder; Elmiyeh, Behrad; Jerjes, Waseem; Prasad, Vyas; Kafas, Panagiotis; Abiola, Jesuloba; Youl, Bryan; Epstein, Ruth; Hopper, Colin; Sudhoff, Holger; Rubin, John

    2009-01-01

    Objectives In this preliminary prospective study, we compared unilateral and bilateral thyroarytenoid muscle injections of Botulinum toxin (Dysport) in 31 patients with adductor spasmodic dysphonia, who had undergone more than 5 consecutive Dysport injections (either unilateral or bilateral) and had completed 5 concomitant self-rated efficacy and complication scores questionnaires related to the previous injections. We also developed a Neurophysiological Scoring (NPS) system which has utility in the treatment administration. Method and materials Data were gathered prospectively on voice improvement (self-rated 6 point scale), length of response and duration of complications (breathiness, cough, dysphagia and total voice loss). Injections were performed under electromyography (EMG) guidance. NPS scale was used to describe the EMG response. Dose and unilateral/bilateral injections were determined by clinical judgment based on previous response. Time intervals between injections were patient driven. Results Low dose unilateral Dysport injection was associated with no significant difference in the patient's outcome in terms of duration of action, voice score (VS) and complication rate when compared to bilateral injections. Unilateral injections were not associated with any post treatment total voice loss unlike the bilateral injections. Conclusion Unilateral low dose Dysport injections are recommended in the treatment of adductor spasmodic dysphonia. PMID:19852852

  18. Determination of injection molding process windows for optical lenses using response surface methodology.

    PubMed

    Tsai, Kuo-Ming; Wang, He-Yi

    2014-08-20

    This study focuses on injection molding process window determination for obtaining optimal imaging optical properties, astigmatism, coma, and spherical aberration using plastic lenses. The Taguchi experimental method was first used to identify the optimized combination of parameters and significant factors affecting the imaging optical properties of the lens. Full factorial experiments were then implemented based on the significant factors to build the response surface models. The injection molding process windows for lenses with optimized optical properties were determined based on the surface models, and confirmation experiments were performed to verify their validity. The results indicated that the significant factors affecting the optical properties of lenses are mold temperature, melt temperature, and cooling time. According to experimental data for the significant factors, the oblique ovals for different optical properties on the injection molding process windows based on melt temperature and cooling time can be obtained using the curve fitting approach. The confirmation experiments revealed that the average errors for astigmatism, coma, and spherical aberration are 3.44%, 5.62%, and 5.69%, respectively. The results indicated that the process windows proposed are highly reliable.

  19. First results of the delayed fluorescence velocimetry as applied to diesel spray diagnostics

    NASA Astrophysics Data System (ADS)

    Megahed, M.; Roosen, P.

    1993-08-01

    One of the main parameters governing diesel spray formation is the fuel's velocity just beneath the nozzle. The high density of the injected liquid within the first few millimeters under the injector prohibits accurate measurements of this velocity. The liquid's velocity in this region has been mainly measured using intrusive methods and has been numerically calculated without considering the complex flow fields in the nozzle. A new optical method based on laser induced delayed fluorescence allowing the measurement of the fuel's velocity close to the nozzle is reported. The results are accurate to about 14% and represent the velocities of heavy oils within the first 2 - 5 mm beneath the nozzle. The development of the velocity over the injection period showed a drastic deceleration of the fuel within the first 3 mm beneath the nozzle. This is assumed to be due to the complex interaction of cavitation in the injection hole and pressure waves in the injection system which causes the start of atomization in the nozzle hole.

  20. Comparing the effectiveness of ultrasound-guided versus blind steroid injection in the treatment of severe carpal tunnel syndrome

    PubMed

    Karaahmet, Özgür Zeliha; Gürçay, Eda; Kara, Murat; Serçe, Azize; Kıraç Ünal, Zeynep; Çakcı, Aytül

    2017-12-19

    Background/aim: This study aimed to compare the effectiveness of ultrasound (US)-guided injection versus blind injection of corticosteroids in the treatment of carpal tunnel syndrome (CTS). Materials and methods: This prospective, randomized clinical trial included patients with severe CTS based on clinical and electrophysiological criteria. The patients were evaluated for clinical and electrophysiological parameters at baseline and 4 weeks after treatment. Symptom severity and hand function were assessed by the Boston questionnaire. The patients underwent blind injection or US-guided injection. Results: When compared with baseline, both groups showed significant improvement in Boston questionnaire scores and all electrophysiological parameters. Significant differences were observed between the groups for clinical parameters (Boston Symptom Severity Scale: P = 0.007; Functional Status Scale: P < 0.001) in favor of the US-guided group. Conclusion: This study demonstrated that both US-guided and blind injections were effective in reducing symptoms and improving hand function. US-guided injections may yield more effective clinical results in the short-term than blind injections in the treatment of patients with severe CTS.

  1. Simulation of mechanical behavior and optimization of simulated injection molding process for PLA based antibacterial composite and nanocomposite bone screws using central composite design.

    PubMed

    Heidari, Behzad Shiroud; Oliaei, Erfan; Shayesteh, Hadi; Davachi, Seyed Mohammad; Hejazi, Iman; Seyfi, Javad; Bahrami, Mozhgan; Rashedi, Hamid

    2017-01-01

    In this study, injection molding of three poly lactic acid (PLA) based bone screws was simulated and optimized through minimizing the shrinkage and warpage of the bone screws. The optimization was carried out by investigating the process factors such as coolant temperature, mold temperature, melt temperature, packing time, injection time, and packing pressure. A response surface methodology (RSM), based on the central composite design (CCD), was used to determine the effects of the process factors on the PLA based bone screws. Upon applying the method of maximizing the desirability function, optimization of the factors gave the lowest warpage and shrinkage for nanocomposite PLA bone screw (PLA9). Moreover, PLA9 has the greatest desirability among the selected materials for bone screw injection molding. Meanwhile, a finite element analysis (FE analysis) was also performed to determine the force values and concentration points which cause yielding of the screws under certain conditions. The Von-Mises stress distribution showed that PLA9 screw is more resistant against the highest loads as compared to the other ones. Finally, according to the results of injection molding simulations, the design of experiments (DOE) and structural analysis, PLA9 screw is recommended as the best candidate for the production of biomedical materials among all the three types of screws. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Intratympanic Iodine Contrast Injection Diffuses Across the Round Window Membrane Allowing for Perilymphatic CT Volume Acquisition Imaging.

    PubMed

    Abt, Nicholas B; Lehar, Mohamed; Guajardo, Carolina Trevino; Penninger, Richard T; Ward, Bryan K; Pearl, Monica S; Carey, John P

    2016-04-01

    Whether the round window membrane (RWM) is permeable to iodine-based contrast agents (IBCA) is unknown; therefore, our goal was to determine if IBCAs could diffuse through the RWM using CT volume acquisition imaging. Imaging of hydrops in the living human ear has attracted recent interest. Intratympanic (IT) injection has shown gadolinium's ability to diffuse through the RWM, enhancing the perilymphatic space. Four unfixed human cadaver temporal bones underwent intratympanic IBCA injection using three sequentially studied methods. The first method was direct IT injection. The second method used direct RWM visualization via tympanomeatal flap for IBCA-soaked absorbable gelatin pledget placement. In the third method, the middle ear was filled with contrast after flap elevation. Volume acquisition CT images were obtained immediately postexposure, and at 1-, 6-, and 24-hour intervals. Postprocessing was accomplished using color ramping and subtraction imaging. After the third method, positive RWM and perilymphatic enhancement were observed with endolymph sparing. Gray scale and color ramp multiplanar reconstructions displayed increased signal within the cochlea compared with precontrast imaging. The cochlea was measured for attenuation differences compared with pure water, revealing a preinjection average of -1,103 HU and a postinjection average of 338 HU. Subtraction imaging shows enhancement remaining within the cochlear space, Eustachian tube, middle ear epithelial lining, and mastoid. Iohexol iodine contrast is able to diffuse across the RWM. Volume acquisition CT imaging was able to detect perilymphatic enhancement at 0.5-mm slice thickness. The clinical application of IBCA IT injection seems promising but requires further safety studies.

  3. An egg injection method for assessing early life stage mortality of polychlorinated dibenzo-p-dioxins, dibenzofurans, and biphenyls in rainbow trout, (Oncorhynchus mykiss)

    USGS Publications Warehouse

    Walker, M.K.; Hufnagle, L.C.; Clayton, M.K.; Peterson, R.E.

    1992-01-01

    To characterize the risk that polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), and biphenyls (PCBs) pose to salmonid early life stage survival, we developed a method to expose rainbow trout (Oncorhynchus mykiss) eggs to graded doses of PCDD, PCDF, and PCB congeners, using 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) as a prototype. Rainbow trout eggs were injected 24–50 h post-fertilization with 0.2 μl of 50 mM phosphatidylcholine (PC) liposomes (control) or 0.2 μl of 5–7 graded doses of TCDD incorporated into 50 mM PC liposomes. Injection volume never exceeded 0.6% egg volume. Immediately following injection, the injection site was sealed with Super glue®, resulting in 92–97% of TCDD dose retained by the egg. Following both egg injection and waterborne egg exposure. TCDD toxicity in rainbow trout was manifested by half-hatching mortality but predominantly by sac fry mortality associated with hemorrhages, pericardial edema, and yolk sac edema. TCDD LD50s, following injection and waterborne exposure of rainbow trout eggs, were 421 (331–489) and 439 (346–519) pg TCDD/g egg (LD50, 95% fiducial limits), respectively. As in rainbow trout, TCDD toxicity in lake trout (Salvelinus namaycush) following the same two routes of exposure was manifested by half-hatching mortality but predominantly by sac fry mortality preceded by hemorrhages and yolk sac edema. LD50s, based on the dose of TCDD in lake trout eggs, were 47 (21–65) and 65 (60–71) pg/g following injection and waterborne exposure, respectively. The egg injection method is ideal for assessing the relationship between early life stage mortality in rainbow trout and graded egg doses of individual PCDD, PCDF, or PCB congeners.

  4. New clinical grading scales and objective measurement for conjunctival injection.

    PubMed

    Park, In Ki; Chun, Yeoun Sook; Kim, Kwang Gi; Yang, Hee Kyung; Hwang, Jeong-Min

    2013-08-05

    To establish a new clinical grading scale and objective measurement method to evaluate conjunctival injection. Photographs of conjunctival injection with variable ocular diseases in 429 eyes were reviewed. Seventy-three images with concordance by three ophthalmologists were classified into a 4-step and 10-step subjective grading scale, and used as standard photographs. Each image was quantified in four ways: the relative magnitude of the redness component of each red-green-blue (RGB) pixel; two different algorithms based on the occupied area by blood vessels (K-means clustering with LAB color model and contrast-limited adaptive histogram equalization [CLAHE] algorithm); and the presence of blood vessel edges, based on the Canny edge-detection algorithm. Area under the receiver operating characteristic curves (AUCs) were calculated to summarize diagnostic accuracies of the four algorithms. The RGB color model, K-means clustering with LAB color model, and CLAHE algorithm showed good correlation with the clinical 10-step grading scale (R = 0.741, 0.784, 0.919, respectively) and with the clinical 4-step grading scale (R = 0.645, 0.702, 0.838, respectively). The CLAHE method showed the largest AUC, best distinction power (P < 0.001, ANOVA, Bonferroni multiple comparison test), and high reproducibility (R = 0.996). CLAHE algorithm showed the best correlation with the 10-step and 4-step subjective clinical grading scales together with high distinction power and reproducibility. CLAHE algorithm can be a useful for method for assessment of conjunctival injection.

  5. Casting evaluation of U-Zr alloy system fuel slug for SFR prepared by injection casting method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Hoon; Kim, Jong-Hwan; Kim, Ki-Hwan

    2013-07-01

    Metal fuel slugs of U-Pu-Zr alloys for Sodium-cooled Fast Reactor (SFR) have conventionally been fabricated by a vacuum injection casting method. Recently, management of minor actinides (MA) became an important issue because direct disposal of the long-lived MA can be a long-term burden for a tentative repository up to several hundreds of thousand years. In order to recycle transuranic elements (TRU) retained in spent nuclear fuel, remote fabrication capability in a shielded hot cell should be prepared. Moreover, generation of long-lived radioactive wastes and loss of volatile species should be minimized during the recycled fuel fabrication step. In order tomore » prevent the evaporation of volatile elements such as Am, alternative fabrication methods of metal fuel slugs have been studied applying gravity casting, and improved injection casting in KAERI, including melting under inert atmosphere. And then, metal fuel slugs were examined with casting soundness, density, chemical analysis, particle size distribution and microstructural characteristics. Based on these results there is a high level of confidence that Am losses will also be effectively controlled by application of a modest amount of overpressure. A surrogate fuel slug was generally soundly cast by improved injection casting method, melted fuel material under inert atmosphere.« less

  6. Development of devices for self-injection: using tribological analysis to optimize injection force

    PubMed Central

    Lange, Jakob; Urbanek, Leos; Burren, Stefan

    2016-01-01

    This article describes the use of analytical models and physical measurements to characterize and optimize the tribological behavior of pen injectors for self-administration of biopharmaceuticals. One of the main performance attributes of this kind of device is its efficiency in transmitting the external force applied by the user on to the cartridge inside the pen in order to effectuate an injection. This injection force characteristic is heavily influenced by the frictional properties of the polymeric materials employed in the mechanism. Standard friction tests are available for characterizing candidate materials, but they use geometries and conditions far removed from the actual situation inside a pen injector and thus do not always generate relevant data. A new test procedure, allowing the direct measurement of the coefficient of friction between two key parts of a pen injector mechanism using real parts under simulated use conditions, is presented. In addition to the absolute level of friction, the test method provides information on expected evolution of friction over lifetime as well as on expected consistency between individual devices. Paired with an analytical model of the pen mechanism, the frictional data allow the expected overall injection system force efficiency to be estimated. The test method and analytical model are applied to a range of polymer combinations with different kinds of lubrication. It is found that material combinations used without lubrication generally have unsatisfactory performance, that the use of silicone-based internal lubricating additives improves performance, and that the best results can be achieved with external silicone-based lubricants. Polytetrafluoroethylene-based internal lubrication and external lubrication are also evaluated but found to provide only limited benefits unless used in combination with silicone. PMID:27274319

  7. Protective Immunity in Mice Achieved with Dry Powder Formulation and Alternative Delivery of Plague F1-V Vaccine▿

    PubMed Central

    Huang, Joanne; D'Souza, Ajit J.; Alarcon, Jason B.; Mikszta, John A.; Ford, Brandi M.; Ferriter, Matthew S.; Evans, Michelle; Stewart, Todd; Amemiya, Kei; Ulrich, Robert G.; Sullivan, Vincent J.

    2009-01-01

    The potential use of Yersinia pestis as a bioterror agent is a great concern. Development of a stable powder vaccine against Y. pestis and administration of the vaccine by minimally invasive methods could provide an alternative to the traditional liquid formulation and intramuscular injection. We evaluated a spray-freeze-dried powder vaccine containing a recombinant F1-V fusion protein of Y. pestis for vaccination against plaque in a mouse model. Mice were immunized with reconstituted spray-freeze-dried F1-V powder via intramuscular injection, microneedle-based intradermal delivery, or noninvasive intranasal administration. By intramuscular injection, the reconstituted powder induced serum antibody responses and provided protection against lethal subcutaneous challenge with 1,000 50% lethal doses of Y. pestis at levels equivalent to those elicited by unprocessed liquid formulations (70 to 90% protection). The feasibility of intradermal and intranasal delivery of reconstituted powder F1-V vaccine was also demonstrated. Overall, microneedle-based intradermal delivery was shown to be similar in efficacy to intramuscular injection, while intranasal administration required an extra dose of vaccine to achieve similar protection. In addition, the results suggest that seroconversion against F1 may be a better predictor of protection against Y. pestis challenge than seroconversion against either F1-V or V. In summary, we demonstrate the preclinical feasibility of using a reconstituted powder F1-V formulation and microneedle-based intradermal delivery to provide protective immunity against plague in a mouse model. Intranasal delivery, while feasible, was less effective than injection in this study. The potential use of these alternative delivery methods and a powder vaccine formulation may result in substantial health and economic benefits. PMID:19261773

  8. Protective immunity in mice achieved with dry powder formulation and alternative delivery of plague F1-V vaccine.

    PubMed

    Huang, Joanne; D'Souza, Ajit J; Alarcon, Jason B; Mikszta, John A; Ford, Brandi M; Ferriter, Matthew S; Evans, Michelle; Stewart, Todd; Amemiya, Kei; Ulrich, Robert G; Sullivan, Vincent J

    2009-05-01

    The potential use of Yersinia pestis as a bioterror agent is a great concern. Development of a stable powder vaccine against Y. pestis and administration of the vaccine by minimally invasive methods could provide an alternative to the traditional liquid formulation and intramuscular injection. We evaluated a spray-freeze-dried powder vaccine containing a recombinant F1-V fusion protein of Y. pestis for vaccination against plaque in a mouse model. Mice were immunized with reconstituted spray-freeze-dried F1-V powder via intramuscular injection, microneedle-based intradermal delivery, or noninvasive intranasal administration. By intramuscular injection, the reconstituted powder induced serum antibody responses and provided protection against lethal subcutaneous challenge with 1,000 50% lethal doses of Y. pestis at levels equivalent to those elicited by unprocessed liquid formulations (70 to 90% protection). The feasibility of intradermal and intranasal delivery of reconstituted powder F1-V vaccine was also demonstrated. Overall, microneedle-based intradermal delivery was shown to be similar in efficacy to intramuscular injection, while intranasal administration required an extra dose of vaccine to achieve similar protection. In addition, the results suggest that seroconversion against F1 may be a better predictor of protection against Y. pestis challenge than seroconversion against either F1-V or V. In summary, we demonstrate the preclinical feasibility of using a reconstituted powder F1-V formulation and microneedle-based intradermal delivery to provide protective immunity against plague in a mouse model. Intranasal delivery, while feasible, was less effective than injection in this study. The potential use of these alternative delivery methods and a powder vaccine formulation may result in substantial health and economic benefits.

  9. [Registration study on analysis of adaptation syndromes and medication characteristics of tanreqing injection].

    PubMed

    Xie, Peng-Yang; Xie, Yan-Ming; Wang, Lian-Xin; Chang, Yan-Peng; You, Li; Zhang, Xiao-Li

    2014-09-01

    Tanreqing injection is suitable for early pneumonia, acute bronchitis, acute exacerbations of chronic, and upper respiratory tract infection which are classified with phlegm-heat obstructing lung syndrome of traditional Chinese medicine. To understand the clinical adaptation syndromes and medication characteristics of the post-market Tanreqing injection, the research team of the paper monitored the patients who are used with Tanreqing injection from September 2012 to October 2013 in four leader hospitals based on the method--prospective, multi-center, large sample, registration-type hospital centralized monitoring,and analyzes the general information, diagnostic information and medication characteristics of patients, in order to produce evidence for clinical practice and medication decisions and to establish the foundation of rational drug use.

  10. Use of borehole radar tomography to monitor steam injection in fractured limestone

    USGS Publications Warehouse

    Gregoire, C.; Joesten, P.K.

    2006-01-01

    Borehole radar tomography was used as part of a pilot study to monitor steam-enhanced remediation of a fractured limestone contaminated with volatile organic compounds at the former Loring Air Force Base, Maine, USA. Radar tomography data were collected using 100-MHz electric-dipole antennae before and during steam injection to evaluate whether cross-hole radar methods could detect changes in medium properties resulting from the steam injection. Cross-hole levelrun profiles, in which transmitting and receiving antennae are positioned at a common depth, were made before and after the collection of each full tomography data set to check the stability of the radar instruments. Before tomographic inversion, the levelrun profiles were used to calibrate the radar tomography data to compensate for changes in traveltime and antenna power caused by instrument drift. Observed changes in cross-hole radar traveltime and attenuation before and during steam injection were small. Slowness- and attenuation-difference tomograms indicate small increases in radar slowness and attenuation at depths greater than about 22 m below the surface, consistent with increases in water temperature observed in the boreholes used for the tomography. Based on theoretical modelling results, increases in slowness and attenuation are interpreted as delineating zones where steam injection heating increased the electrical conductivity of the limestone matrix and fluid. The results of this study show the potential of cross-hole radar tomography methods to monitor the effects of steam-induced heating in fractured rock environments. ?? 2006 European Association of Geoscientists & Engineers.

  11. Detection of Peptide-based nanoparticles in blood plasma by ELISA.

    PubMed

    Bode, Gerard H; Pickl, Karin E; Sanchez-Purrà, Maria; Albaiges, Berta; Borrós, Salvador; Pötgens, Andy J G; Schmitz, Christoph; Sinner, Frank M; Losen, Mario; Steinbusch, Harry W M; Frank, Hans-Georg; Martinez-Martinez, Pilar

    2015-01-01

    The aim of the current study was to develop a method to detect peptide-linked nanoparticles in blood plasma. A convenient enzyme linked immunosorbent assay (ELISA) was developed for the detection of peptides functionalized with biotin and fluorescein groups. As a proof of principle, polymerized pentafluorophenyl methacrylate nanoparticles linked to biotin-carboxyfluorescein labeled peptides were intravenously injected in Wistar rats. Serial blood plasma samples were analyzed by ELISA and by liquid chromatography mass spectrometry (LC/MS) technology. The ELISA based method for the detection of FITC labeled peptides had a detection limit of 1 ng/mL. We were able to accurately measure peptides bound to pentafluorophenyl methacrylate nanoparticles in blood plasma of rats, and similar results were obtained by LC/MS. We detected FITC-labeled peptides on pentafluorophenyl methacrylate nanoparticles after injection in vivo. This method can be extended to detect nanoparticles with different chemical compositions.

  12. Item Anomaly Detection Based on Dynamic Partition for Time Series in Recommender Systems

    PubMed Central

    Gao, Min; Tian, Renli; Wen, Junhao; Xiong, Qingyu; Ling, Bin; Yang, Linda

    2015-01-01

    In recent years, recommender systems have become an effective method to process information overload. However, recommendation technology still suffers from many problems. One of the problems is shilling attacks-attackers inject spam user profiles to disturb the list of recommendation items. There are two characteristics of all types of shilling attacks: 1) Item abnormality: The rating of target items is always maximum or minimum; and 2) Attack promptness: It takes only a very short period time to inject attack profiles. Some papers have proposed item anomaly detection methods based on these two characteristics, but their detection rate, false alarm rate, and universality need to be further improved. To solve these problems, this paper proposes an item anomaly detection method based on dynamic partitioning for time series. This method first dynamically partitions item-rating time series based on important points. Then, we use chi square distribution (χ2) to detect abnormal intervals. The experimental results on MovieLens 100K and 1M indicate that this approach has a high detection rate and a low false alarm rate and is stable toward different attack models and filler sizes. PMID:26267477

  13. Item Anomaly Detection Based on Dynamic Partition for Time Series in Recommender Systems.

    PubMed

    Gao, Min; Tian, Renli; Wen, Junhao; Xiong, Qingyu; Ling, Bin; Yang, Linda

    2015-01-01

    In recent years, recommender systems have become an effective method to process information overload. However, recommendation technology still suffers from many problems. One of the problems is shilling attacks-attackers inject spam user profiles to disturb the list of recommendation items. There are two characteristics of all types of shilling attacks: 1) Item abnormality: The rating of target items is always maximum or minimum; and 2) Attack promptness: It takes only a very short period time to inject attack profiles. Some papers have proposed item anomaly detection methods based on these two characteristics, but their detection rate, false alarm rate, and universality need to be further improved. To solve these problems, this paper proposes an item anomaly detection method based on dynamic partitioning for time series. This method first dynamically partitions item-rating time series based on important points. Then, we use chi square distribution (χ2) to detect abnormal intervals. The experimental results on MovieLens 100K and 1M indicate that this approach has a high detection rate and a low false alarm rate and is stable toward different attack models and filler sizes.

  14. Fish egg injection as an alternative exposure route for early life stage toxicity studies: Description of two unique methods: Chapter 4

    USGS Publications Warehouse

    Walker, Mary K.; Zabel, Erik W.; Akerman, Gun; Balk, Lennart; Wright, Peggy J.; Tillitt, Donald E.

    1996-01-01

    In the environment, lipophilic contaminants such as halogenated aromatic hydrocarbons (HAHs, e.g., polychlorinated biphenyls, PCBs) and polycyclic aromatic hydrocarbons (PAHs, e.g., benzo[a]pyrene) readily bioaccumulate in fish, and the bioaccumulation of these lipophilic chemicals by adult fish may have significant consequences on the development and survival of their offspring. Halogenated and polycyclic aromatic hydrocarbons translocate from adult female body stores into eggs during oocyte maturation, and early life stages of fish are often more sensitive than adults to the toxicity of these chemicals. Thus, the presence of persistent, bioaccumulative contaminants in the environment may pose a risk to fish early life stage survival and ultimately reduce recruitment into the adult population.Typically, standard early life stage toxicity studies exposed embryos, larvae, and juveniles to graded concentrations of waterborne toxicants, and dose-response relationships are based on the concentrations of chemicals in the water. However, use of waterborne exposure to assess the toxicity of persistent, bioaccumulative contaminants, such as HAHs and PAHs, has two significant drawbacks. First, uptake of hydrophobic chemicals, such as HAHs and PAHs, into the developing embryo from water is not a significant route of exposure in the environment since concentrations of these chemicals freely dissolved in water are extremely low. Rather, maternal deposition into developing oocytes is the most significant source of these chemicals to the embryo. Second, the dose received by the target tissue, in this case the developing embryo, is the most accurate predictor of the toxic response, and since extrapolation from water concentrations of the chemical to egg concentrations is required, the exact dose received by the embryo can only be estimated, often with large uncertainty. Due to these drawbacks, it is important to develop an alternative exposure method that will directly expose the developing embryo without the need to chronically expose adult fish with subsequent natural deposition of hydrophobic chemicals into the oocytes. Fish egg injection provides this exposure route. Embryos are exposed directly after fertilization with known doses of contaminants, the dose is delivered prior to critical developmental events, and extrapolation of the dose received by the embryo is not needed.We have developed two unique fish egg injection methods as alternative routes of exposure for fish early life stage toxicity studies of lipophilic environmental contaminants. With either method, individual fish eggs are injected with a known dose of chemical. The first approach, a microinjection method, originally developed to assess the developmental toxicity of HAH congeners to early life stages of salmonids, utilizes micro-syringes, 30- gauge stainless steel injection needles, and micro- to nanoliter injection volume. The second approach, a nano-injection method, utilizes glass capillary micropipettes with 2 to 10 µm tips as injection needles, and nano- to picoliter injection volume, allowing injection of nearly any size of fish egg.Both of these egg injection methods allow an investigator to assess the toxicity of lipophilic environmental contaminants to early life stages of fish in a manner that realistically reflects environmental exposure and allows accurate quantitation of the dose to the developing embryo. These injection techniques, however, are not limited to use with only lipophilic chemicals. Since the developmental toxicity of many environmental contaminants ultimately depends on the dose received by the embryo, these egg injection methods could serve as a realistic exposure route in many fish early life stage toxicity studies.

  15. Flow injection analysis-flame atomic absorption spectrometry system for indirect determination of sulfite after on-line reduction of solid-phase manganese (IV) dioxide reactor.

    PubMed

    Zare-Dorabei, Rouholah; Boroun, Shokoufeh; Noroozifar, Meissam

    2018-02-01

    A new and simple flow injection method followed by atomic absorption spectrometry was developed for indirect determination of sulfite. The proposed method is based on the oxidation of sulfite to sulphate ion using solid-phase manganese dioxide (30% W/W suspended on silica gel beads) reactor. MnO 2 will be reduced to Mn(II) by sample injection in to the column under acidic carrier stream of HNO 3 (pH 2) with flow rate of 3.5mLmin -1 at room temperature. Absorption measurement of Mn(II) which is proportional to the concentration of sulfite in the sample was carried out by atomic absorption spectrometry. The calibration curve was linear up to 25mgL -1 with a detection limit (DL) of 0.08mgL -1 for 400µL injection sample volume. The presented method is efficient toward sulfite determination in sugar and water samples with a relative standard deviation (RSD) less than 1.2% and a sampling rate of about 60h -1 . Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Microsphere-Based Rapamycin Delivery, Systemic Versus Local Administration in a Rat Model of Renal Ischemia/Reperfusion Injury.

    PubMed

    Zandstra, Jurjen; van Beuge, Marike M; Zuidema, Johan; Petersen, Arjen H; Staal, Mark; Duque, Luisa F; Rodriguez, Sergio; Lathuile, Audrey A R; Veldhuis, Gert J; Steendam, Rob; Bank, Ruud A; Popa, Eliane R

    2015-10-01

    The increasing prevalence and treatment costs of kidney diseases call for innovative therapeutic strategies that prevent disease progression at an early stage. We studied a novel method of subcapsular injection of monodisperse microspheres, to use as a local delivery system of drugs to the kidney. We generated placebo- and rapamycin monodisperse microspheres to investigate subcapsular delivery of drugs. Using a rat model of acute kidney injury, subcapsular injection of placebo and rapamycin monodisperse microspheres (monospheres) was compared to subcutaneous injection, mimicking systemic administration. We did not find any adverse effects related to the delivery method. Irrespective of the injection site, a similar low dose of rapamycin was present in the circulation. However, only local intrarenal delivery of rapamycin from monospheres led to decreased macrophage infiltration and a significantly lower amount of myofibroblasts in the kidney, where systemic administration did not. Local delivery of rapamycin did cause a transient increase in the deposition of collagen I, but not of collagen III. We conclude that therapeutic effects can be increased when rapamycin is delivered subcapsularly by monospheres, which, combined with low systemic concentrations, may lead to an effective intrarenal delivery method.

  17. Fast Ignition and Sustained Combustion of Ionic Liquids

    NASA Technical Reports Server (NTRS)

    Joshi, Prakash B. (Inventor); Piper, Lawrence G. (Inventor); Oakes, David B. (Inventor); Sabourin, Justin L. (Inventor); Hicks, Adam J. (Inventor); Green, B. David (Inventor); Tsinberg, Anait (Inventor); Dokhan, Allan (Inventor)

    2016-01-01

    A catalyst free method of igniting an ionic liquid is provided. The method can include mixing a liquid hypergol with a HAN (Hydroxylammonium nitrate)-based ionic liquid to ignite the HAN-based ionic liquid in the absence of a catalyst. The HAN-based ionic liquid and the liquid hypergol can be injected into a combustion chamber. The HAN-based ionic liquid and the liquid hypergol can impinge upon a stagnation plate positioned at top portion of the combustion chamber.

  18. Therapeutic effects of adipose-derived stem cells-based microtissues on erectile dysfunction in streptozotocin-induced diabetic rats

    PubMed Central

    Zhou, Feng; Hui, Yu; Xin, Hua; Xu, Yong-De; Lei, Hong-En; Yang, Bi-Cheng; Guan, Rui-Li; Li, Meng; Hou, Jian-Quan; Xin, Zhong-Cheng

    2017-01-01

    This study aimed to explore the therapeutic effects of adipose-derived stem cells (ADSCs)-based microtissues (MTs) on erectile dysfunction (ED) in streptozotocin (STZ)-induced diabetic rats. Fifty-six 8-week-old Sprague-Dawley rats received intraperitoneal injection of STZ (60 mg kg−1), and 8 weeks later, the determined diabetic rats randomly received intracavernous (IC) injection of phosphate buffer solution (PBS), ADSCs, or MTs. Another eight normal rats equally got IC injection of PBS. MTs were generated with a hanging drop method, and the injected cells were tracked in ADSC- and MT-injected rats. Four weeks after the treatments, intracavernous pressure (ICP), histopathological changes in corpus cavernosum (CC), and functional proteins were measured. Rat cytokine antibody array was used to detect ADSCs or MTs lysate. The results showed that MTs expressed vascular endothelial growth factor (VEGF), nerve growth factor (NGF), and tumor necrosis factor-stimulated gene-6 (TSG-6). MTs injection had a higher retention than ADSCs injection and MTs treatment improved ICP, neuronal nitric oxide synthase (nNOS) expression, smooth muscle, and endothelial contents in diabetic rats, ameliorated local inflammation in CC better. Thus, our findings demonstrate that IC injection of MTs improves erectile function and histopathological changes in STZ-induced diabetic rats and appears to be more promising than traditional ADSCs. The underlying mechanisms involve increased cell retention accompanied with neuroprotection and anti-inflammatory behaviors of the paracrine factors. PMID:27345005

  19. Injectable contraception. New and existing options.

    PubMed

    Kaunitz, A M

    2000-12-01

    DMPA and MPA/E2C contraception offer women safe, effective, convenient, and reversible birth control choices. The use of DMPA, a 3-month injectable, is characteristically associated with amenorrhea. Lactating women and women in whom contraceptive doses of estrogen are contraindicated can use this progestin-only birth control method. Return of fertility can be delayed in women discontinuing DMPA to become pregnant. In some cases, the use of DMPA also confers important noncontraceptive and therapeutic benefits. A monthly estrogen/progestin injectable contraceptive, MPA/E2C should appeal to women who are concerned about daily pill taking, who prefer regular cycles to amenorrhea, and who find monthly injections acceptable and accessible. As is true for oral contraceptives, MPA/E2C represents an appropriate choice for women who prefer a rapidly reversible contraceptive. Currently, the proposed contraindications for MPA/E2C parallel those for combined oral contraceptives. As MPA/E2C contraception becomes available for American women, clinicians will learn how to best include this new method among the array of contraceptive choices. By individualizing contraceptive selection, counseling, and management approaches based on the relevant behavioral and medical considerations reviewed herein, clinicians can maximize their patients' success with injectable contraceptives. The more innovative that clinicians, family planning agencies, and insurers are in facilitating access to care (including reinjections), the more women will be able to avail themselves of safe, effective, and reversible methods of contraception. In addition to the physician's office or health clinic, other sites at which women might receive contraceptive injections include employee health clinics, college health clinics, or perhaps the pharmacy where the prescription is filled. Self-administration may become an appropriate option for some users of injectable contraception.

  20. Optimal joule heating of the subsurface

    DOEpatents

    Berryman, J.G.; Daily, W.D.

    1994-07-05

    A method for simultaneously heating the subsurface and imaging the effects of the heating is disclosed. This method combines the use of tomographic imaging (electrical resistance tomography or ERT) to image electrical resistivity distribution underground, with joule heating by electrical currents injected in the ground. A potential distribution is established on a series of buried electrodes resulting in energy deposition underground which is a function of the resistivity and injection current density. Measurement of the voltages and currents also permits a tomographic reconstruction of the resistivity distribution. Using this tomographic information, the current injection pattern on the driving electrodes can be adjusted to change the current density distribution and thus optimize the heating. As the heating changes conditions, the applied current pattern can be repeatedly adjusted (based on updated resistivity tomographs) to affect real time control of the heating.

  1. Augmented reality intravenous injection simulator based 3D medical imaging for veterinary medicine.

    PubMed

    Lee, S; Lee, J; Lee, A; Park, N; Lee, S; Song, S; Seo, A; Lee, H; Kim, J-I; Eom, K

    2013-05-01

    Augmented reality (AR) is a technology which enables users to see the real world, with virtual objects superimposed upon or composited with it. AR simulators have been developed and used in human medicine, but not in veterinary medicine. The aim of this study was to develop an AR intravenous (IV) injection simulator to train veterinary and pre-veterinary students to perform canine venipuncture. Computed tomographic (CT) images of a beagle dog were scanned using a 64-channel multidetector. The CT images were transformed into volumetric data sets using an image segmentation method and were converted into a stereolithography format for creating 3D models. An AR-based interface was developed for an AR simulator for IV injection. Veterinary and pre-veterinary student volunteers were randomly assigned to an AR-trained group or a control group trained using more traditional methods (n = 20/group; n = 8 pre-veterinary students and n = 12 veterinary students in each group) and their proficiency at IV injection technique in live dogs was assessed after training was completed. Students were also asked to complete a questionnaire which was administered after using the simulator. The group that was trained using an AR simulator were more proficient at IV injection technique using real dogs than the control group (P ≤ 0.01). The students agreed that they learned the IV injection technique through the AR simulator. Although the system used in this study needs to be modified before it can be adopted for veterinary educational use, AR simulation has been shown to be a very effective tool for training medical personnel. Using the technology reported here, veterinary AR simulators could be developed for future use in veterinary education. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  2. RNA Interference of the Muscle Actin Gene in Bed Bugs: Exploring Injection Versus Topical Application for dsRNA Delivery.

    PubMed

    Basnet, Sanjay; Kamble, Shripat T

    2018-05-01

    Bed bugs are one the most troublesome household pests that feed primarily on human blood. RNA interference (RNAi) is currently being pursued as a potential tool for insect population management and has shown efficacy against some phytophagous insects. We evaluated the different techniques to deliver dsRNA specific to bed bug muscle actin (dsactin) into bed bugs. Initially, stability of dsRNA in human blood was studied to evaluate the feasibility of feeding method. Adult bed bugs were injected with dsRNA between last thoracic segment and first abdominal segment on the ventral side, with a dose of 0.2 µg dsactin per insect. In addition to injection, dsactin was mixed in acetone and treated topically in the abdomens of fifth stage nymphs. We found the quick degradation of dsRNA in blood. Injection of dsactin caused significant depletion of actin transcripts and substantial reduction in oviposition and lethality in female adults. Topically treated dsRNA in fifth stage nymphs had no effect on actin mRNA expression and survival. Our results demonstrated that injection is a reliable method of dsRNA delivery into bed bugs while topical treatment was not successful. This research provides an understanding on effective delivery methods of dsRNA into bed bugs for functional genomics research and feasibility of the RNAi based molecules for pest management purposes.

  3. Policy and programmatic considerations for introducing a longer-acting injectable contraceptive: perspectives of stakeholders from Kenya and Rwanda

    PubMed Central

    McKenna, Kevin; Arcara, Jennet; Rademacher, Kate H; Mackenzie, Caroline; Ngabo, Fidele; Munyambanza, Emmanuel; Wesson, Jennifer; Tolley, Elizabeth E

    2014-01-01

    ABSTRACT Background: More than 40 million women use injectable contraceptives to prevent pregnancy, and most current or previous injectable users report being satisfied with the method. However, while women may find injectables acceptable, they may not always find them accessible due to stock-outs and difficulties with returning to the clinic for reinjections. FHI 360 is spearheading efforts to develop a longer-acting injectable (LAI) contraceptive that could provide at least 6 months of protection against pregnancy. This article addresses systems-level considerations for the introduction of a new LAI. Methods: We conducted qualitative case studies in Kenya and Rwanda—two countries that have high levels of injectable use but with different service delivery contexts. Between June and September 2012, we conducted in-depth interviews with 27 service providers and 19 policy makers and program implementers focusing on 4 themes: systems-level barriers and facilitators to delivering LAI services; process for introducing an LAI; LAI distribution approaches; and potential LAI characteristics. We also obtained electronic feedback from 28 international family planning opinion leaders. Results: Respondents indicated strong interest in an LAI and thought it would appeal to existing injectable users as well as new family planning clients, both for spacing and for limiting births. Providers appreciated the potential for a lighter workload due to fewer follow-up visits, but they were concerned that fewer visits would also decrease their ability to help women manage side effects. The providers also appreciated the 1-month grace period for follow-up LAI injections; some seemed unaware of the latest international guidance that had increased the grace period from 2 weeks to 4 weeks for the currently available 3-month injectable. The majority of policy makers and program implementers were supportive of letting community health workers provide the method, but many nurses and midwives in Kenya had reservations about the approach. At the policy level, respondents indicated that obtaining regulatory approvals before introducing the new method could be costly and time-consuming. Manufacturing and procurement decisions could also affect cost and availability. Conclusions: Successful introduction of a potential longer-acting injectable may be enhanced by considering broader systemic issues, including managing cost to the health system and users, expanding access through community-based distribution, and training providers on the latest service delivery guidelines. PMID:25611479

  4. N-bromosuccinimide-fluorescein based sensitive flow-injection chemiluminescence determination of phenformin.

    PubMed

    Wang, Zhouping; Zhang, Zhujun; Fu, Zhifeng; Fang, Luqiu; Zhang, Xiao

    2004-02-01

    A novel and highly sensitive method for the determination of phenformin over the range of 6 x 10(-9) - 1 x 10(-5) g ml(-1) in pharmaceutical formulations with flow-injection chemiluminescence (CL) detection is proposed. The method is based on the CL produced during the oxidation of N-bromosuccinimide (NBS) in an alkaline medium in the presence of fluorescein as an effective energy transfer agent. The use of cetyltrimethylammonium bromide (CTAB) as a sensitizer enhances the signal magnitude by about 100 times. The detection limit is 2 x 10(-9) g ml(-1) (3sigma) with a relative standard deviation of 2.3% (n = 11) at 1 x 10(-7) g ml(-1) phenformin. Ninety samples can be determined per hour. The method was evaluated by carrying out a recovery study and by the analysis of commercial formulations. The obtained results compared well with those by an official method, and demonstrated good accuracy and precision. The possible CL mechanism of the proposed system was also briefly analyzed.

  5. Evidence-Based Modification of Intratympanic Gentamicin Injections in Patients With Intractable Vertigo

    PubMed Central

    Zhai, Feng; Liu, Jian-Ping; Dai, Chun-Fu; Wang, Qi; Steyger, Peter S.

    2013-01-01

    Objectives To compare the cochlear distribution of low-dose fluorescent gentamicin after intra-tympanic administration in guinea pig (GPs) with clinical data of low dose intra-tympanic gentamicin in patients with intractable vertigo. Materials and Methods Purified gentamicin-Texas Red (GTTR) was injected intratympanically into GPs and the cochlear distribution and time course of GTTR fluorescence in outer hair cells (OHCs) was determined using confocal microscopy. Results GTTR was rapidly taken up by OHCs, particularly in the subcuticular zone. GTTR was distributed in the cochlea in a decreasing baso-apical gradient, and was retained within OHCs without significant decrease in fluorescence until 4 weeks after injection. Conclusion OHCs rapidly take up GTTR after intra-tympanic administration with slow clearance. Clinical Application A modified low-dose titration intratympanic approach was applied to patients with intractable Ménière’s Disease (MD) based on our animal data and the clinical outcome was followed. After the modified intratympanic injections for MD patients, vertigo control was achieved in 89% patients, with hearing deterioration identified in 16% patients. The 3-week interval titration injection technique thereby had a relatively high vertigo control rate with a low risk of hearing loss, and is a viable alternative to other intratympanic injection protocols. PMID:20393376

  6. Flow injection chemiluminescence determination of lercanidipine based on N-chlorosuccinimide-eosin Y post-chemiluminescence reaction.

    PubMed

    Wang, Guowei; Zhao, Fang; Gao, Ying

    2014-12-01

    A novel post-chemiluminescence (PCL) reaction was discovered when lercanidipine was injected into the CL reaction mixture of N-chlorosuccinimide with alkaline eosin Y in the presence of cetyltrimethylammonium bromide (CTAB), where eosin Y was used as the CL reagent and CTAB as the surfactant. Based on this observation, a simple and highly sensitive PCL method combined with a flow injection (FI) technique was developed for the assay of lercanidipine. Under optimum conditions, the CL signal was linearly related to the concentration of lercanidipine in the range 7.0 × 10(-10) to 3.0 × 10(-6)  g/mL with a detection limit of 2.3 × 10(-10) g/mL (3σ). The relative standard deviation (RSD) was 2.1% for 1.0 × 10(-8) g/mL lercanidipine (n = 13). The proposed method had been applied to the estimation of lercanidipine in tablets and human serum samples with satisfactory results. The possible CL mechanism is also discussed briefly. Copyright © 2014 John Wiley & Sons, Ltd.

  7. Randomized trial of anesthetic methods for intravitreal injections.

    PubMed

    Blaha, Gregory R; Tilton, Elisha P; Barouch, Fina C; Marx, Jeffrey L

    2011-03-01

    To compare the effectiveness of four different anesthetic methods for intravitreal injection. Twenty-four patients each received four intravitreal injections using each of four types of anesthesia (proparacaine, tetracaine, lidocaine pledget, and subconjunctival injection of lidocaine) in a prospective, masked, randomized block design. Pain was graded by the patient on a 0 to 10 scale for both the anesthesia and the injection. The average combined pain scores for both the anesthesia and the intravitreal injection were 4.4 for the lidocaine pledget, 3.5 for topical proparacaine, 3.8 for the subconjunctival lidocaine injection, and 4.1 for topical tetracaine. The differences were not significant (P = 0.65). There were also no statistical differences in the individual anesthesia or injection pain scores. Subconjunctival lidocaine injection had the most side effects. Topical anesthesia is an effective method for limiting pain associated with intravitreal injections.

  8. Ultra trace determination of 31 pesticides in water samples by direct injection-rapid resolution liquid chromatography-electrospray tandem mass spectrometry.

    PubMed

    Díaz, Laura; Llorca-Pórcel, Julio; Valor, Ignacio

    2008-08-22

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method for the detection of pesticides in tap and treated wastewater was developed and validated according to the ISO/IEC 17025:1999. Key features of this method include direct injection of 100 microL of sample, an 11 min separation by means of a rapid resolution liquid chromatography system with a 4.6 mm x 50 mm, 1.8 microm particle size reverse phase column and detection by electrospray ionization (ESI) MS-MS. The limits of detection were below 15 ng L(-1) and correlation coefficients for the calibration curves in the range of 30-2000 ng L(-1) were higher than 0.99. Precision was always below 20% and accuracy was confirmed by external evaluation. The main advantages of this method are direct injection of sample without preparative procedures and low limits of detection that fulfill the requirements established by the current European regulations governing pesticide detection.

  9. Simple and clean determination of tetracyclines by flow injection analysis

    NASA Astrophysics Data System (ADS)

    Rodríguez, Michael Pérez; Pezza, Helena Redigolo; Pezza, Leonardo

    2016-01-01

    An environmentally reliable analytical methodology was developed for direct quantification of tetracycline (TC) and oxytetracycline (OTC) using continuous flow injection analysis with spectrophotometric detection. The method is based on the diazo coupling reaction between the tetracyclines and diazotized sulfanilic acid in a basic medium, resulting in the formation of an intense orange azo compound that presents maximum absorption at 434 nm. Experimental design was used to optimize the analytical conditions. The proposed technique was validated over the concentration range of 1 to 40 μg mL- 1, and was successfully applied to samples of commercial veterinary pharmaceuticals. The detection (LOD) and quantification (LOQ) limits were 0.40 and 1.35 μg mL- 1, respectively. The samples were also analyzed by an HPLC method, and the results showed agreement with the proposed technique. The new flow injection method can be immediately used for quality control purposes in the pharmaceutical industry, facilitating monitoring in real time during the production processes of tetracycline formulations for veterinary use.

  10. [Comparative study on four kinds of assessment methods of post-marketing safety of Danhong injection].

    PubMed

    Li, Xuelin; Tang, Jinfa; Meng, Fei; Li, Chunxiao; Xie, Yanming

    2011-10-01

    To study the adverse reaction of Danhong injection with four kinds of methods, central monitoring method, chart review method, literature study method and spontaneous reporting method, and to compare the differences between them, explore an appropriate method to carry out post-marketing safety evaluation of traditional Chinese medicine injection. Set down the adverse reactions' questionnaire of four kinds of methods, central monitoring method, chart review method, literature study method and collect the information on adverse reactions in a certain period. Danhong injection adverse reaction information from Henan Province spontaneous reporting system was collected with spontaneous reporting method. Carry on data summary and descriptive analysis. Study the adverse reaction of Danhong injection with four methods of central monitoring method, chart review method, literature study method and spontaneous reporting method, the rates of adverse events were 0.993%, 0.336%, 0.515%, 0.067%, respectively. Cyanosis, arrhythmia, hypotension, sweating, erythema, hemorrhage dermatitis, rash, irritability, bleeding gums, toothache, tinnitus, asthma, elevated aminotransferases, constipation, pain are new discovered adverse reactions. The central monitoring method is the appropriate method to carry out post-marketing safety evaluation of traditional Chinese medicine injection, which could objectively reflect the real world of clinical usage.

  11. Vas deferens occlusion by percutaneous injection of polyurethane elastomer plugs: clinical experience and reversibility.

    PubMed

    Zhao, S C

    1990-05-01

    A non-incision method of vas occlusion based on the percutaneous injection of polyurethane elastomer solution to form plugs is described. The results are based on clinical experience in 12,000 men in which only 56 cases of minor complications were recorded. Follow-up of 500 men for up to 3 years demonstrated an azoospermia rate of 98%. Plugs have been removed from 86 men and, to date, 51 have made their wives pregnant. In those from which the plugs have been removed for more than 1 year (n = 31), the pregnancy rate is 100%.

  12. A New Biolistic Intradermal Injector Based on a Miniature Shock Tube

    NASA Astrophysics Data System (ADS)

    Brouillette, M.

    Intradermal powder injection is an emerging technology for the needlefree delivery of a potentially wide array of drugs and vaccines. Although needle injection of liquids is widespread principally because of its low cost, this delivery method is painful, generates dangerous medical waste and can cause contamination. Various technologies have been developed to address these shortcomings, amongst them creams, patches, inhalers and liquid jet injectors, each with their own severe limitations.

  13. Finite difference time domain (FDTD) method for modeling the effect of switched gradients on the human body in MRI.

    PubMed

    Zhao, Huawei; Crozier, Stuart; Liu, Feng

    2002-12-01

    Numerical modeling of the eddy currents induced in the human body by the pulsed field gradients in MRI presents a difficult computational problem. It requires an efficient and accurate computational method for high spatial resolution analyses with a relatively low input frequency. In this article, a new technique is described which allows the finite difference time domain (FDTD) method to be efficiently applied over a very large frequency range, including low frequencies. This is not the case in conventional FDTD-based methods. A method of implementing streamline gradients in FDTD is presented, as well as comparative analyses which show that the correct source injection in the FDTD simulation plays a crucial rule in obtaining accurate solutions. In particular, making use of the derivative of the input source waveform is shown to provide distinct benefits in accuracy over direct source injection. In the method, no alterations to the properties of either the source or the transmission media are required. The method is essentially frequency independent and the source injection method has been verified against examples with analytical solutions. Results are presented showing the spatial distribution of gradient-induced electric fields and eddy currents in a complete body model. Copyright 2002 Wiley-Liss, Inc.

  14. Can Land Managers Control Japanese Knotweed? Lessons from Control Tests in Belgium

    NASA Astrophysics Data System (ADS)

    Delbart, Emmanuel; Mahy, Grégory; Weickmans, Bernard; Henriet, François; Crémer, Sébastien; Pieret, Nora; Vanderhoeven, Sonia; Monty, Arnaud

    2012-12-01

    Japanese knotweed Fallopia japonica is an extremely abundant invasive plant in Belgium and surrounding countries. To date, no eradication method is available for land managers facing the invasion of this rhizomatous plant. We tested different chemical herbicides with two application methods (spraying and stem injection), as well as mechanical treatments, on knotweed clones throughout southern Belgium. The tested control methods were selected to be potentially usable by managers, e.g., using legally accepted rates for herbicides. Stem volume, height and density reduction were assessed after one or two years, depending on the control method. Labor estimations were made for each control method. No tested control method completely eradicated the clones. Stem injection with glyphosate-based herbicide (3.6 kg ha-1 of acid equivalent glyphosate) caused the most damage, i.e., no sprouting shoots were observed the year following the injection. The following year, though, stunted shoots appeared. Among the mechanical control methods, repeated cuts combined with native tree transplanting most appreciably reduced knotweed development. The most efficient methods we tested could curb knotweed invasion, but are not likely to be effective in eradicating the species. As such, they should be included in a more integrated restoration strategy, together with prevention and public awareness campaigns.

  15. Deltoid Injections of Risperidone Long-acting Injectable in Patients with Schizophrenia

    PubMed Central

    Quiroz, Jorge A.; Rusch, Sarah; Thyssen, An; Kushner, Stuart

    2011-01-01

    Background Risperidone long-acting injectable was previously approved for treatment of schizophrenia as biweekly injections in the gluteal muscle only. We present data on local injection-site tolerability and safety of risperidone long-acting injectable and comparability of systemic exposure of deltoid versus gluteal injections. Methods Risperidone long-acting injectable was administered in an open-label, single-dose, two-way crossover study, with patients randomized to receive either 25mg gluteal/37.5mg deltoid crossover in two treatment periods or 50mg gluteal/50mg deltoid injections crossover; each treatment period was separated by an 85-day observation period (Study 1) and an open-label, multiple-dose study (4 sequential 37.5mg or 50mg deltoid injections every 2 weeks) (Study 2). The pharmacokinetic results from both the studies have already been published. Results In Study 1 (n=170), the majority of patients had no local injection-site findings, based on investigator and patient-rated evaluations. In Study 2 (n=53), seven of the 51 patients who received at least two deltoid injections discontinued (primary endpoint). However, none of the discontinuations were due to injection-site related reasons. The 90-percent upper confidence limit of the true proportion of injection-site issue withdrawals was 5.7 percent. No moderate or severe injection-site reactions were reported. Conclusion Intramuscular injections via the deltoid and gluteal sites are equivalent routes of administration of risperidone long-acting injectable with respect to local injection-site tolerability. The overall safety and tolerability profile of risperidone long-acting injectable was comparable when administered as an intramuscular injection in the deltoid (37.5mg and 50mg) and gluteal (25mg and 50mg) sites. PMID:21779538

  16. Determination of gallic acid with rhodanine by reverse flow injection analysis using simplex optimization.

    PubMed

    Phakthong, Wilaiwan; Liawruangrath, Boonsom; Liawruangrath, Saisunee

    2014-12-01

    A reversed flow injection (rFI) system was designed and constructed for gallic acid determination. Gallic acid was determined based on the formation of chromogen between gallic acid and rhodanine, resulting in a colored product with a λmax at 520 nm. The optimum conditions for determining gallic acid were also investigated. Optimizations of the experimental conditions were carried out based on the so-call univariate method. The conditions obtained were 0.6% (w/v) rhodanine, 70% (v/v) ethanol, 0.9 mol L(-1) NaOH, 2.0 mL min(-1) flow rate, 75 μL injection loop and 600 cm mixing tubing length, respectively. Comparative optimizations of the experimental conditions were also carried out by multivariate or simplex optimization method. The conditions obtained were 1.2% (w/v) rhodanine, 70% (v/v) ethanol, 1.2 mol L(-1) NaOH, flow rate 2.5 mL min(-1), 75 μL injection loop and 600 cm mixing tubing length, respectively. It was found that the optimum conditions obtained by the former optimization method were mostly similar to those obtained by the latter method. The linear relationship between peak height and the concentration of gallic acid was obtained over the range of 0.1-35.0 mg L(-1) with the detection limit 0.081 mg L(-1). The relative standard deviations were found to be in the ranges 0.46-1.96% for 1, 10, 30 mg L(-1) of gallic acid (n=11). The method has the advantages of simplicity extremely high selectivity and high precision. The proposed method was successfully applied to the determination of gallic acid in longan samples without interferent effects from other common phenolic compounds that might be present in the longan samples collected in northern Thailand. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Heat transfer to a full-coverage film-cooled surface with 30 degree slant-hole injection

    NASA Technical Reports Server (NTRS)

    Crawford, M. E.; Kays, W. M.; Moffat, R. J.

    1976-01-01

    Heat transfer behavior was studied in a turbulent boundary layer with full coverage film cooling through an array of discrete holes and with injection 30 deg to the wall surface in the downstream direction. Stanton numbers were measured for a staggered hole pattern with pitch-to-diameter ratios of 5 and 10, an injection mass flux ratio range of 0.1 to 1.3, and a range of Reynolds number Re sub x of 150,000 to 5 million. Air was used as the working fluid, and the mainstream velocity varied from 9.8 to 34.2 m/sec (32 to 112 ft/sec). The data were taken for secondary injection temperature equal to the wall temperature and also equal to the mainstream temperature. The data may be used to obtain Stanton number as a continuous function of the injectant temperature by use of linear superposition theory. The heat transfer coefficient is defined on the basis of a mainstream-to-wall temperature difference. This definition permits direct comparison of performance between film cooling and transpiration cooling. A differential prediction method was developed to predict the film cooling data base. The method utilizes a two-dimensional boundary layer program with routines to model the injection process and turbulence augmentation. The program marches in the streamwise direction, and when a row of holes is encountered, it stops and injects fluid into the boundary layer. The turbulence level is modeled by algebraically augmenting the mixing length, with the augmentation keyed to a penetration distance for the injected fluid.

  18. Single-shot measurements of low emittance beams from laser-plasma accelerators comparing two triggered injection methods

    NASA Astrophysics Data System (ADS)

    van Tilborg, Jeroen

    2017-10-01

    The success of laser plasma accelerator (LPA) based applications, such as a compact x-ray free electron laser (FEL), relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot energy-dispersed emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock-induced density down-ramp injection. Both injection mechanisms have gained in popularity in recent years due to their demonstrated stable LPA performance. For the down-ramp injection configuration, normalized emittances a factor of two lower were recorded: less than 1 micron at spectral charge densities up to 2 pC/MeV. For both injection mechanisms, a contributing correlation of space charge to the emittance was identified. This measurement technique in general, and these results specifically, are critical to the evaluation of LPA injection methods and development of high-quality LPA beam lines worldwide. This work is supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the U.S. DOE NNSA, DNN R&D (NA22), by the National Science Foundation under Grant No. PHY-1415596, and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  19. A comprehensive situation assessment of injection practices in primary health care hospitals in Bangladesh

    PubMed Central

    2011-01-01

    Background Understanding injection practices is crucial for evidence-based development of intervention initiatives. This study explored the extent of injection use and injection safety practices in primary care hospitals in Bangladesh. Methods The study employed both quantitative and qualitative research methods. The methods used were - a retrospective audit of prescriptions (n = 4320), focus group discussions (six with 43 participants), in-depth interviews (n = 38) with a range service providers, and systematic observation of the activities of injection providers (n = 120), waste handlers (n = 48) and hospital facilities (n = 24). Quantitative and qualitative data were assessed with statistical and thematic analysis, respectively, and then combined. Results As many as 78% of our study sample (n = 4230) received an injection. The most commonly prescribed injections (n = 3354) including antibiotics (78.3%), IV fluids (38.6%), analgesics/pain killers (29.4%), vitamins (26.7%), and anti-histamines (18.5%). Further, 43.7% (n = 1145) of the prescribed antibiotics (n = 2626) were given to treat diarrhea and 42.3% (n = 600) of IV fluids (n = 1295) were used to manage general weakness conditions. Nearly one-third (29.8%; n = 36/120) of injection providers reported needle-stick injuries in the last 6 months with highest incidences in Rajshahi division followed by Dhaka division. Disposal of injection needles, syringes and other materials was not done properly in 83.5% (n = 20/24) of the facilities. Health providers' safety concerns were not addressed properly; only 23% (n = 28/120) of the health providers and 4.2% (n = 2/48) of the waste handlers were fully immunized against Hepatitis B virus. Moreover, 73% (n = 87/120) of the injection providers and 90% (n = 43/48) of the waste handlers were not trained in injection safety practices and infection prevention. Qualitative data further confirmed that both providers and patients preferred injections, believing that they provide quick relief. The doctors' perceived injection use as their prescribing norm that enabled them to prove their professional credibility and to remain popular in a competitive health care market. Additionally, persistent pressure from hospital administration to use up injections before their expiry dates also influenced doctors to prescribe injections regardless of actual indications. Conclusions As far as the patients and providers' safety is concerned, this study demonstrated a need for further research exploring the dynamics of injection use and safety in Bangladesh. In a context where a high level of injection use and unsafe practices were reported, immediate prevention initiatives need to be operated through continued intervention efforts and health providers' training in primary care hospitals in Bangladesh. PMID:21985397

  20. Reevaluation of the post-marketing safety of Shuxuening injection based on real-world and evidence-based evaluations.

    PubMed

    Wang, Can; Shi, Qing-Ping; Ding, Feng; Jiang, Xiao-Dong; Tang, Wei; Yu, Mei-Ling; Zhu, Jian-Hua

    2018-01-01

    To evaluate the factors influencing suspected hypersensitivity and adverse systemic reactions after Shuxuening injection and to provide innovative ideas and methods for the reevaluation of post-marketing safety of Shuxuening. This study used a prospective, nested case-control study design, combined with a prescription sequence analysis design method. It classified patients who exhibited trigger signals after administration of Shuxuening injection as suspected allergic patients and made comparisons with patients who did not report adverse effects to calculate the correlation between relevant risk factors and suspected allergic reactions. Randomized controlled studies and cohort studies of the adverse drug reaction (ADR) of Shuxuening were performed using a computer database. Data retrieval was carried out by the foundation governing the individual database. Meta-analysis was performed by using R3.2.3 software to evaluate the ADRs of Shuxuening. The results of real-world study showed that administration of Shuxuening in combination with potassium aspartate and magnesium, atorvastatin calcium, Shengmai injection, pantoprazole sodium, or high-dose medication was a risk factor for suspected allergic reactions. Meta-analysis showed that the incidence of adverse events was 5.84% (95% CI 0.0499; 0.0674), and serious adverse reaction rate was 4.36% (95% CI 0.0188; 0.0760) when Shuxuening was used in combination with these drugs. The incidence of allergic reaction was also influenced by the vehicle, duration of treatment, single dose, and indicated vs off-label use. Risk factors for adverse reaction following the use of Shuxuening injection in patients are associated with a single dose, vehicle, type of disease, and combination with potassium aspartate, atorvastatin calcium, Shengmai injection, injection with pantoprazole sodium, and other drugs. Physicians should be careful to follow guidelines when administering this drug. We further propose that the unique methodology used in this study may be useful for reevaluation of the safety of other traditional Chinese medicines.

  1. Flow Injection Analysis with Electrochemical Detection for Rapid Identification of Platinum-Based Cytostatics and Platinum Chlorides in Water

    PubMed Central

    Kominkova, Marketa; Heger, Zbynek; Zitka, Ondrej; Kynicky, Jindrich; Pohanka, Miroslav; Beklova, Miroslava; Adam, Vojtech; Kizek, Rene

    2014-01-01

    Platinum-based cytostatics, such as cisplatin, carboplatin or oxaliplatin are widely used agents in the treatment of various types of tumors. Large amounts of these drugs are excreted through the urine of patients into wastewaters in unmetabolised forms. This phenomenon leads to increased amounts of platinum ions in the water environment. The impacts of these pollutants on the water ecosystem are not sufficiently investigated as well as their content in water sources. In order to facilitate the detection of various types of platinum, we have developed a new, rapid, screening flow injection analysis method with electrochemical detection (FIA-ED). Our method, based on monitoring of the changes in electrochemical behavior of analytes, maintained by various pH buffers (Britton-Robinson and phosphate buffer) and potential changes (1,000, 1,100 and 1,200 mV) offers rapid and cheap selective determination of platinum-based cytostatics and platinum chlorides, which can also be present as contaminants in water environments. PMID:24499878

  2. Theoretical analysis of a method for extracting the phase of a phase-amplitude modulated signal generated by a direct-modulated optical injection-locked semiconductor laser

    NASA Astrophysics Data System (ADS)

    Lee, Hwan; Cho, Jun-Hyung; Sung, Hyuk-Kee

    2017-05-01

    The phase modulation (PM) and amplitude modulation (AM) of optical signals can be achieved using a direct-modulated (DM) optical injection-locked (OIL) semiconductor laser. We propose and theoretically analyze a simple method to extract the phase component of a PM signal produced by a DM-OIL semiconductor laser. The pure AM component of the combined PM-AM signal can be isolated by square-law detection in a photodetector and can then be used to compensate for the PM-AM signal based on an optical homodyne method. Using the AM compensation technique, we successfully developed a simple and cost-effective phase extraction method applicable to the PM-AM optical signal of a DM-OIL semiconductor laser.

  3. Simulated fault injection - A methodology to evaluate fault tolerant microprocessor architectures

    NASA Technical Reports Server (NTRS)

    Choi, Gwan S.; Iyer, Ravishankar K.; Carreno, Victor A.

    1990-01-01

    A simulation-based fault-injection method for validating fault-tolerant microprocessor architectures is described. The approach uses mixed-mode simulation (electrical/logic analysis), and injects transient errors in run-time to assess the resulting fault impact. As an example, a fault-tolerant architecture which models the digital aspects of a dual-channel real-time jet-engine controller is used. The level of effectiveness of the dual configuration with respect to single and multiple transients is measured. The results indicate 100 percent coverage of single transients. Approximately 12 percent of the multiple transients affect both channels; none result in controller failure since two additional levels of redundancy exist.

  4. An Automated Mouse Tail Vascular Access System by Vision and Pressure Feedback.

    PubMed

    Chang, Yen-Chi; Berry-Pusey, Brittany; Yasin, Rashid; Vu, Nam; Maraglia, Brandon; Chatziioannou, Arion X; Tsao, Tsu-Chin

    2015-08-01

    This paper develops an automated vascular access system (A-VAS) with novel vision-based vein and needle detection methods and real-time pressure feedback for murine drug delivery. Mouse tail vein injection is a routine but critical step for preclinical imaging applications. Due to the small vein diameter and external disturbances such as tail hair, pigmentation, and scales, identifying vein location is difficult and manual injections usually result in poor repeatability. To improve the injection accuracy, consistency, safety, and processing time, A-VAS was developed to overcome difficulties in vein detection noise rejection, robustness in needle tracking, and visual servoing integration with the mechatronics system.

  5. Method of injection of onabotulinumtoxinA for chronic migraine: a safe, well-tolerated, and effective treatment paradigm based on the PREEMPT clinical program.

    PubMed

    Blumenfeld, Andrew; Silberstein, Stephen D; Dodick, David W; Aurora, Sheena K; Turkel, Catherine C; Binder, William J

    2010-10-01

    Chronic migraine (CM) is a prevalent and disabling neurological disorder. Few prophylactic treatments for CM have been investigated. OnabotulinumtoxinA, which inhibits the release of nociceptive mediators, such as glutamate, substance P, and calcitonin gene-related peptide, has been evaluated in randomized, placebo-controlled studies for the preventive treatment of a variety of headache disorders, including CM. These studies have yielded insight into appropriate patient selection, injection sites, dosages, and technique. Initial approaches used a set of fixed sites for the pericranial injections. However, the treatment approach evolved to include other sites that corresponded to the location of pain and tenderness in the individual patient in addition to the fixed sites. The Phase III REsearch Evaluating Migraine Prophylaxis Therapy (PREEMPT) injection paradigm uses both fixed and follow-the-pain sites, with additional specific follow-the-pain sites considered depending on individual symptoms. The PREEMPT paradigm for injecting onabotulinumtoxinA has been shown to be safe, well-tolerated, and effective in well-designed, controlled clinical trials and is the evidence-based approach recommended to optimize clinical outcomes for patients with CM. © 2010 American Headache Society.

  6. Numerical investigation of complex flooding schemes for surfactant polymer based enhanced oil recovery

    NASA Astrophysics Data System (ADS)

    Dutta, Sourav; Daripa, Prabir

    2015-11-01

    Surfactant-polymer flooding is a widely used method of chemical enhanced oil recovery (EOR) in which an array of complex fluids containing suitable and varying amounts of surfactant or polymer or both mixed with water is injected into the reservoir. This is an example of multiphase, multicomponent and multiphysics porous media flow which is characterized by the spontaneous formation of complex viscous fingering patterns and is modeled by a system of strongly coupled nonlinear partial differential equations with appropriate initial and boundary conditions. Here we propose and discuss a modern, hybrid method based on a combination of a discontinuous, multiscale finite element formulation and the method of characteristics to accurately solve the system. Several types of flooding schemes and rheological properties of the injected fluids are used to numerically study the effectiveness of various injection policies in minimizing the viscous fingering and maximizing oil recovery. Numerical simulations are also performed to investigate the effect of various other physical and model parameters such as heterogeneity, relative permeability and residual saturation on the quantities of interest like cumulative oil recovery, sweep efficiency, fingering intensity to name a few. Supported by the grant NPRP 08-777-1-141 from the Qatar National Research Fund (a member of The Qatar Foundation).

  7. A simple and sensitive flow injection method based on the catalytic activity of CdS quantum dots in an acidic permanganate chemiluminescence system for determination of formaldehyde in water and wastewater.

    PubMed

    Khataee, Alireza; Lotfi, Roya; Hasanzadeh, Aliyeh; Iranifam, Mortaza

    2016-04-01

    A simple and sensitive flow injection chemiluminescence (CL) method in which CdS quantum dots (QDs) enhanced the CL intensity of a KMnO4-formaldehyde (HCHO) reaction was offered for the determination of HCHO. This CL system was based on the catalytic activity of CdS QDs and their participation in the CL resonance energy transfer (CRET) phenomenon. A possible mechanism for the supplied CL system was proposed using the kinetic curves of the CL systems and the spectra of CL, photoluminescence (PL) and ultraviolet-visible (UV-Vis). The emanated CL intensity of the KMnO4-CdS QDs system was amplified in the presence of a trace level of HCHO. Based on this enhancement effect, a simple and sensitive flow injection CL method was suggested for the determination of HCHO concentration in environmental water and wastewater samples. Under selected optimized experimental conditions, the increased CL intensity was proportional to the HCHO concentration in the range of 0.03-4.5 μg L(-1) and 4.5-10.0 μg L(-1). The detection limits (3σ) were 0.0003 μg L(-1) and 1.2 μg L(-1). The relative standard deviations (RSD%) for eleven replicate determinations of 4.0 μg L(-1) HCHO were 2.2%. Furthermore, the feasibility of the developed method was investigated via the determination of HCHO concentration in environmental water and wastewater samples.

  8. Violence, trauma and living with HIV: Longitudinal predictors of initiating crystal methamphetamine injection among sex workers

    PubMed Central

    Argento, Elena; Strathdee, Steffanie A.; Goldenberg, Shira; Braschel, Melissa; Montaner, Julio; Shannon, Kate

    2017-01-01

    Background Despite rapid increases in crystal methamphetamine (CM) use worldwide and established gendered patterns of use, empirical research on CM injection initiation among sex workers is limited. Given the wide range of harms associated with CM, alongside stimulant effects including sexual dis-inhibition and prolonged awake-ness, this study aimed to longitudinally investigate socio-structural predictors of initiating CM injection among sex workers in Vancouver, Canada. Methods Data (2010–2014) were drawn from a community-based cohort of women sex workers: AESHA (An Evaluation of Sex Workers Health Access). Participants completed biannual interviewer-administered questionnaires and HIV/STI testing. Kaplan Meier methods and Cox proportional hazards regression were used to model predictors of CM injection initiation among CM injection-naïve participants. Results Of 455 participants eligible at baseline, 14.3% (n=65) injected CM for the first time over follow-up, with an incidence density of 6.79 per 100 person-years (95% Confidence Interval [CI] 5.30–8.69). In multivariable analysis, injection heroin use (Adjusted Hazard Ratio [AHR] 6.11; 95%CI 3.24–11.52), having an intimate partner who injects drugs (AHR 2.93; 95%CI 1.57–5.46), workplace violence (AHR 2.85; 95%CI 1.74–4.67), HIV seropositivity (AHR 2.69; 95%CI 1.45–5.00), and childhood abuse (AHR 1.86; 95%CI 0.99–3.49) were independently associated with initiating CM injection. Conclusions Findings underscore the gendered and social risk environment of CM injection initiation among sex workers. The strong influences of historical/workplace violence, coupled with heroin injection (known to be self-medicating for post-traumatic stress) as a primary risk pathway, emphasize the urgency of increasing access to integrated, trauma-informed addiction treatment and HIV care for marginalized women. PMID:28448903

  9. Resonant interaction of the electron beam with a synchronous wave in controlled magnetrons for high-current superconducting accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kazakevich, G.; Johnson, R.; Lebedev, V.

    A simplified analytical model of the resonant interaction of the beam of Larmor electrons drifting in the crossed constant fields of a magnetron with a synchronous wave providing a phase grouping of the drifting charge was developed to optimize the parameters of an rf resonant injected signal driving the magnetrons for management of phase and power of rf sources with a rate required for superconducting high-current accelerators. The model, which considers the impact of the rf resonant signal injected into the magnetron on the operation of the injection-locked tube, substantiates the recently developed method of fast power control of magnetronsmore » in the range up to 10 dB at the highest generation efficiency, with low noise, precise stability of the carrier frequency, and the possibility of wideband phase control. Experiments with continuous wave 2.45 GHz, 1 kW microwave oven magnetrons have verified the correspondence of the behavior of these tubes to the analytical model. A proof of the principle of the novel method of power control in magnetrons, based on the developed model, was demonstrated in the experiments. The method is attractive for high-current superconducting rf accelerators. This study also discusses vector methods of power control with the rates required for superconducting accelerators, the impact of the rf resonant signal injected into the magnetron on the rate of phase control of the injection-locked tubes, and a conceptual scheme of the magnetron transmitter with highest efficiency for high-current accelerators.« less

  10. Resonant interaction of the electron beam with a synchronous wave in controlled magnetrons for high-current superconducting accelerators

    DOE PAGES

    Kazakevich, G.; Johnson, R.; Lebedev, V.; ...

    2018-06-14

    A simplified analytical model of the resonant interaction of the beam of Larmor electrons drifting in the crossed constant fields of a magnetron with a synchronous wave providing a phase grouping of the drifting charge was developed to optimize the parameters of an rf resonant injected signal driving the magnetrons for management of phase and power of rf sources with a rate required for superconducting high-current accelerators. The model, which considers the impact of the rf resonant signal injected into the magnetron on the operation of the injection-locked tube, substantiates the recently developed method of fast power control of magnetronsmore » in the range up to 10 dB at the highest generation efficiency, with low noise, precise stability of the carrier frequency, and the possibility of wideband phase control. Experiments with continuous wave 2.45 GHz, 1 kW microwave oven magnetrons have verified the correspondence of the behavior of these tubes to the analytical model. A proof of the principle of the novel method of power control in magnetrons, based on the developed model, was demonstrated in the experiments. The method is attractive for high-current superconducting rf accelerators. This study also discusses vector methods of power control with the rates required for superconducting accelerators, the impact of the rf resonant signal injected into the magnetron on the rate of phase control of the injection-locked tubes, and a conceptual scheme of the magnetron transmitter with highest efficiency for high-current accelerators.« less

  11. Computerized Dental Injection Fear Treatment

    PubMed Central

    Heaton, L.J.; Leroux, B.G.; Ruff, P.A.; Coldwell, S.E.

    2013-01-01

    One in four adults reports a clinically significant fear of dental injections, leading many to avoid dental care. While systematic desensitization is the most common therapeutic method for treating specific phobias such as fear of dental injections, lack of access to trained therapists, as well as dentists’ lack of training and time in providing such a therapy, means that most fearful individuals are not able to receive the therapy needed to be able to receive necessary dental treatment. Computer Assisted Relaxation Learning (CARL) is a self-paced computerized treatment based on systematic desensitization for dental injection fear. This multicenter, block-randomized, dentist-blind, parallel-group study conducted in 8 sites in the United States compared CARL with an informational pamphlet in reducing fear of dental injections. Participants completing CARL reported significantly greater reduction in self-reported general and injection-specific dental anxiety measures compared with control individuals (p < .001). Twice as many CARL participants (35.3%) as controls (17.6%) opted to receive a dental injection after the intervention, although this was not statistically significant. CARL, therefore, led to significant changes in self-reported fear in study participants, but no significant differences in the proportion of participants having a dental injection (ClinicalTrials.gov, NCT00609648). PMID:23690352

  12. EVALUATION OF IODINE BASED IMPINGER SOLUTIONS FOR THE EFFICIENT CAPTURE OF HG USING DIRECT INJECTION NEBULIZATION INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY (DIN-ICP/MS) ANALYSIS

    EPA Science Inventory

    Currently there are no EPA reference sampling methods that have been promulgated for measuring stack emissions of Hg from coal combustion sources, however, EPA Method 29 is most commonly applied. The draft ASTM Ontario Hydro Method for measuring oxidized, elemental, particulate-b...

  13. Policing Behaviors, Safe Injection Self-Efficacy, and Intervening on Injection Risks: Moderated Mediation Results from a Randomized Trial

    PubMed Central

    Pitpitan, Eileen V.; Patterson, Thomas L.; Abramovitz, Daniela; Vera, Alicia; Martinez, Gustavo; Staines, Hugo; Strathdee, Steffanie A.

    2015-01-01

    Objective We aim to use conditional, or moderated mediation to simultaneously test how and for whom an injection risk intervention was efficacious at reducing receptive needle sharing among female sex workers who inject drugs (FSWs-IDUs) in Mexico. Methods Secondary analysis of data from a randomized trial. A total of 300 FSW-IDUs participated in Mujer Mas Segura in Ciudad Juarez, Mexico and were randomized to an interactive injection risk intervention or a didactic injection risk intervention. We measured safe injection self-efficacy as the hypothesized mediator, and policing behaviors (being arrested and syringe confiscation) as hypothesized moderators. 213 women provided complete data for the current analyses. Results Conditional (moderated) mediation showed that the intervention affected receptive needle sharing through safe injection self-efficacy among women who experienced syringe confiscation. On average, police syringe confiscation was associated with lower safe injection self-efficacy (p = 0.04). Among those who experienced syringe confiscation, those who received the interactive (vs. didactic) intervention reported higher self-efficacy, which in turn predicted lower receptive needle sharing (p = 0.04). Conclusions Whereas syringe confiscation by the police negatively impacted safe injection self-efficacy and ultimately injection risk behavior, our interactive intervention helped to “buffer” this negative impact of police behavior on risky injection practices. The theory-based, active skills building elements included in the interactive condition, which were absent from the didactic condition, helped participants’ self-efficacy for safer injection in the face of syringe confiscation. PMID:26120851

  14. Numerical analysis of combustion characteristics of hybrid rocket motor with multi-section swirl injection

    NASA Astrophysics Data System (ADS)

    Li, Chengen; Cai, Guobiao; Tian, Hui

    2016-06-01

    This paper is aimed to analyse the combustion characteristics of hybrid rocket motor with multi-section swirl injection by simulating the combustion flow field. Numerical combustion flow field and combustion performance parameters are obtained through three-dimensional numerical simulations based on a steady numerical model proposed in this paper. The hybrid rocket motor adopts 98% hydrogen peroxide and polyethylene as the propellants. Multiple injection sections are set along the axis of the solid fuel grain, and the oxidizer enters the combustion chamber by means of tangential injection via the injector ports in the injection sections. Simulation results indicate that the combustion flow field structure of the hybrid rocket motor could be improved by multi-section swirl injection method. The transformation of the combustion flow field can greatly increase the fuel regression rate and the combustion efficiency. The average fuel regression rate of the motor with multi-section swirl injection is improved by 8.37 times compared with that of the motor with conventional head-end irrotational injection. The combustion efficiency is increased to 95.73%. Besides, the simulation results also indicate that (1) the additional injection sections can increase the fuel regression rate and the combustion efficiency; (2) the upstream offset of the injection sections reduces the combustion efficiency; and (3) the fuel regression rate and the combustion efficiency decrease with the reduction of the number of injector ports in each injection section.

  15. A decline in the prevalence of injecting drug users in Estonia, 2005–2009

    PubMed Central

    Uusküla, A; Rajaleid, K; Talu, A; Abel-Ollo, K; Des Jarlais, DC

    2013-01-01

    Aims and setting Descriptions of behavioural epidemics have received little attention compared with infectious disease epidemics in Eastern Europe. Here we report a study aimed at estimating trends in the prevalence of injection drug use between 2005 and 2009 in Estonia. Design and methods The number of injection drug users (IDUs) aged 15–44 each year between 2005 and 2009 was estimated using capture-recapture methodology based on 4 data sources (2 treatment data bases: drug abuse and non-fatal overdose treatment; criminal justice (drug related offences) and mortality (injection drug use related deaths) data). Poisson log-linear regression models were applied to the matched data, with interactions between data sources fitted to replicate the dependencies between the data sources. Linear regression was used to estimate average change over time. Findings there were 24305, 12292, 238, 545 records and 8100, 1655, 155, 545 individual IDUs identified in the four capture sources (Police, drug treatment, overdose, and death registry, accordingly) over the period 2005 – 2009. The estimated prevalence of IDUs among the population aged 15–44 declined from 2.7% (1.8–7.9%) in 2005 to 2.0% (1.4–5.0%) in 2008, and 0.9% (0.7–1.7%) in 2009. Regression analysis indicated an average reduction of over 1700 injectors per year. Conclusion While the capture-recapture method has known limitations, the results are consistent with other data from Estonia. Identifying the drivers of change in the prevalence of injection drug use warrants further research. PMID:23290632

  16. Online solid-phase extraction with high-performance liquid chromatography and mass spectrometry for the determination of five tannins in traditional Chinese medicine injections.

    PubMed

    Sun, Meng; Lin, Yuanyuan; Zhang, Jie; Zheng, Shaohua; Wang, Sicen

    2016-03-01

    A rapid analytical method based on online solid-phase extraction with high-performance liquid chromatography and mass spectrometry has been established and applied to the determination of tannin compounds that may cause adverse effects in traditional Chinese medicine injections. Different solid-phase extraction sorbents have been compared and the elution buffer was optimized. The performance of the method was verified by evaluation of recovery (≥40%), repeatability (RSD ≤ 6%), linearity (r(2) ≥ 0.993), and limit of quantification (≤0.35 μg/mL). Five tannin compounds, gallic acid, cianidanol, gallocatechin gallate, ellagic acid, and penta-O-galloylglucose, were identified with concentrations ranging from 3.1-37.4 μg/mL in the analyzed traditional Chinese medicine injections. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid.

    PubMed

    van Staden, J F; Mashamba, Mulalo G; Stefan, Raluca I

    2002-09-01

    An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid is proposed. A solution of 0.1 mol L(-1) sodium chloride is used as carrier. Titration is achieved by aspirating acetic acid samples between two strong base-zone volumes into a holding coil and by channelling the stack of well-defined zones with flow reversal through a reaction coil to a potentiometric sensor where the peak widths were measured. A linear relationship between peak width and logarithm of the acid concentration was obtained in the range 1-9 g/100 mL. Vinegar samples were analysed without any sample pre-treatment. The method has a relative standard deviation of 0.4% with a sample frequency of 28 samples per hour. The results revealed good agreement between the proposed sequential injection and an automated batch titration method.

  18. Crosslinking method of hyaluronic-based hydrogel for biomedical applications

    PubMed Central

    Khunmanee, Sureerat; Jeong, Younghyen; Park, Hansoo

    2017-01-01

    In the field of tissue engineering, there is a need for advancement beyond conventional scaffolds and preformed hydrogels. Injectable hydrogels have gained wider admiration among researchers as they can be used in minimally invasive surgical procedures. Injectable gels completely fill the defect area and have good permeability and hence are promising biomaterials. The technique can be effectively applied to deliver a wide range of bioactive agents, such as drugs, proteins, growth factors, and even living cells. Hyaluronic acid is a promising candidate for the tissue engineering field because of its unique physicochemical and biological properties. Thus, this review provides an overview of various methods of chemical and physical crosslinking using different linkers that have been investigated to develop the mechanical properties, biodegradation, and biocompatibility of hyaluronic acid as an injectable hydrogel in cell scaffolds, drug delivery systems, and wound healing applications. PMID:28912946

  19. Dexamethasone levels and base to apex concentration gradients in scala tympani perilymph following intracochlear delivery in the guinea pig

    PubMed Central

    Hahn, Hartmut; Salt, Alec N.; Biegner, Thorsten; Kammerer, Bernd; Delabar, Ursular; Hartsock, Jared; Plontke, Stefan K.

    2012-01-01

    Hypothesis To determine whether intracochlearly applied dexamethasone will lead to better control of drug levels, higher peak concentrations and lower base-to apex concentration gradients in scala tympani (ST) of the guinea pig than after intratympanic (round window, RW) application. Background Local application of drugs to the RW results in substantial variation of intracochlear drug levels and significant base-to apex concentration gradients in ST. Methods Two μL of dexamethasone-phosphate (10 mg/mL) were injected into ST either through the RW membrane which was covered with 1% sodium hyaluronate gel or through a cochleostomy with a fluid tight seal of the micropipette. Perilymph was sequentially sampled from the apex at a single time point for each animal, at 20, 80, or 200 min after the injection ended. Results were mathematically interpreted by the means of an established computer model and compared with prior experiments performed by our group with the same experimental techniques but using intratympanic applications. Results Single intracochlear injections over 20 min resulted in approximately ten times higher peak concentrations (on average) than 2-3 hours of intratympanic application to the round window niche. Intracochlear drug levels were less variable and could be measured for at least up to 220 min. Concentration gradients along scala tympani were less pronounced. The remaining variability in intracochlear drug levels was attributable to perilymph and drug leak from the injection site. Conclusion With significantly higher, less variable drug levels and smaller base-to apex concentration gradients, intracochlear applications have advantages to intratympanic injections. For further development of this technique, it is of importance to control leaks of perilymph and drug from the injection site and to evaluate its clinical feasibility and associated risks. PMID:22588238

  20. Diverse HIV epidemics among people who inject drugs in Thailand: evidence from respondent-driven sampling surveys in Bangkok and Chiang Mai.

    PubMed

    Prybylski, Dimitri; Manopaiboon, Chomnad; Visavakum, Prin; Yongvanitjit, Kovit; Aramrattana, Apinun; Manomaipiboon, Parnrudee; Tanpradech, Suvimon; Suksripanich, Orapin; Pattanasin, Sarika; Wolfe, Mitchell; Whitehead, Sara J

    2015-03-01

    Thailand's long-standing HIV sero-sentinel surveillance system for people who inject drugs (PWID) is confined to those in methadone-based drug treatment clinics and representative data are scarce, especially outside of Bangkok. We conducted probability-based respondent-driven sampling (RDS) surveys in Bangkok (n=738) and Chiang Mai (n=309) to increase understanding of local HIV epidemics and to better inform the planning of evidence-based interventions. PWID had different epidemiological profiles in these two cities. Overall HIV prevalence was higher in Bangkok (23.6% vs. 10.9%, p<0.001) but PWID in Bangkok are older and appear to have long-standing HIV infections. In Chiang Mai, HIV infections appear to be more recently acquired and PWID were younger and had higher levels of recent injecting and sexual risk behaviors with lower levels of intervention exposure. Methamphetamine was the predominant drug injected in both sites and polydrug use was common although levels and patterns of the specific drugs injected varied significantly between the sites. In multivariate analysis, recent midazolam injection was significantly associated with HIV infection in Chiang Mai (adjusted odds ratio=8.1; 95% confidence interval: 1.2-54.5) whereas in Bangkok HIV status was not associated with recent risk behaviors as infections had likely been acquired in the past. PWID epidemics in Thailand are heterogeneous and driven by local factors. There is a need to customize intervention strategies for PWID in different settings and to integrate population-based survey methods such as RDS into routine surveillance to monitor the national response. Published by Elsevier Ireland Ltd.

  1. [Application of fingerprint chromatogram in quality control of Shen-Mai injection].

    PubMed

    Shi, Xian-zhe; Yang, Jun; Zhao, Chun-xia; Xiong, Jian-hui; Xu, Guo-wang

    2002-07-01

    The theory and practice of traditional Chinese medicine require some comprehensive methods to assess quality of the Chinese herbal medication. Fingerprint chromatogram is one of the feasible approaches to evaluate the quality of Chinese herbal medication. So the fingerprint chromatogram of Shen-Mai injection was established by using reversed-phase high performance liquid chromatography. The chromatographic conditions were as follows: a Hypersil C18 column was used; the mobile phase was composed of water (A) and acetontrile (B) with linear gradient elution (0-50 min, 5%-95% B, volume fraction); the flow rate was 1.0 mL/min and the UV absorbance detection was set at 202 nm. The peak-area ratios of twenty-three fingerprint peaks and internal standard (diphenyl) were taken as the criteria for quality control. The quality differences in various batches and various manufacturers of Shen-Mai injections were investigated by projection discriminance based on principal component analysis. The results show the method developed is convenient, reliable and applicable for the quality control analysis of Shen-Mai injection.

  2. Photovoltaic Hosting Capacity of Feeders with Reactive Power Control and Tap Changers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ceylan, Oğuzhan; Paudyal, Sumit; Bhattarai, Bishnu P.

    This paper proposes an algorithm to determine photovoltaic (PV) hosting capacity of power distribution networks as a function of number of PV injection nodes, reactive power support from the PVs, and the sub-station load tap changers (LTCs). In the proposed method, several minute by minute simulations are run based on randomly chosen PV injection nodes, daily PV output profiles, and daily load profiles from a pool of high-resolution realistic data set. The simulation setup is built using OpenDSS and MATLAB. The performance of the proposed method is investigated in the IEEE 123-node distribution feeder for multiple scenarios. The case studiesmore » are performed particularly for one, two, five and ten PV injection nodes, and looking at the maximum voltage deviations. Case studies show that the PV hosting capacity of the 123-node feeder greatly differs with the number of PV injection nodes. We have also observed that the PV hosting capacity increases with reactive power support and higher tap position of sub-station LTC.« less

  3. Uncertainty Quantification for Robust Control of Wind Turbines using Sliding Mode Observer

    NASA Astrophysics Data System (ADS)

    Schulte, Horst

    2016-09-01

    A new quantification method of uncertain models for robust wind turbine control using sliding-mode techniques is presented with the objective to improve active load mitigation. This approach is based on the so-called equivalent output injection signal, which corresponds to the average behavior of the discontinuous switching term, establishing and maintaining a motion on a so-called sliding surface. The injection signal is directly evaluated to obtain estimates of the uncertainty bounds of external disturbances and parameter uncertainties. The applicability of the proposed method is illustrated by the quantification of a four degree-of-freedom model of the NREL 5MW reference turbine containing uncertainties.

  4. Ultrasound-assisted emulsification microextraction combined with injection-port derivatization for the determination of some chlorophenoxyacetic acids in water samples.

    PubMed

    Yamini, Yadollah; Saleh, Abolfazl

    2013-07-01

    An efficient method based on ultrasound-assisted emulsification microextraction followed by injection-port derivatization GC analysis was developed to determine 2,4-dichlorophenoxyacetic acid (2,4-D) and 4-chloro-2-methylphenoxyacetic acid (MCPA) in natural water samples. In this procedure, 12.5 μL of 1-undecanol was injected slowly into a 12 mL home-designed centrifuge glass vial containing an aqueous sample of the analytes located inside an ultrasonic water bath. The resulting emulsion was centrifuged, and 1 μL of the separated organic solvent together with 1 μL of the derivatization reagent were injected into a GC equipped with a flame ionization detector. Several factors that influence the derivatization and extraction were optimized. Under the optimal conditions, the LODs were 0.33 and 1.7 μg/L for MCPA and 2,4-D, respectively. Preconcentration factors of 670 and 836 were obtained for MCPA and 2,4-D, respectively. The precision of the proposed method was evaluated in terms of repeatability, which was <5.7% (n = 5). The applicability of the proposed method was evaluated by extraction and determination of chlorophenoxyacetic acids from some natural waters, which indicated that the matrices of natural waters have no significant effect on the extraction and derivatization efficiency of this method. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. A non-inheritable maternal Cas9-based multiple-gene editing system in mice.

    PubMed

    Sakurai, Takayuki; Kamiyoshi, Akiko; Kawate, Hisaka; Mori, Chie; Watanabe, Satoshi; Tanaka, Megumu; Uetake, Ryuichi; Sato, Masahiro; Shindo, Takayuki

    2016-01-28

    The CRISPR/Cas9 system is capable of editing multiple genes through one-step zygote injection. The preexisting method is largely based on the co-injection of Cas9 DNA (or mRNA) and guide RNAs (gRNAs); however, it is unclear how many genes can be simultaneously edited by this method, and a reliable means to generate transgenic (Tg) animals with multiple gene editing has yet to be developed. Here, we employed non-inheritable maternal Cas9 (maCas9) protein derived from Tg mice with systemic Cas9 overexpression (Cas9 mice). The maCas9 protein in zygotes derived from mating or in vitro fertilization of Tg/+ oocytes and +/+ sperm could successfully edit the target genome. The efficiency of such maCas9-based genome editing was comparable to that of zygote microinjection-based genome editing widely used at present. Furthermore, we demonstrated a novel approach to create "Cas9 transgene-free" gene-modified mice using non-Tg (+/+) zygotes carrying maCas9. The maCas9 protein in mouse zygotes edited nine target loci simultaneously after injection with nine different gRNAs alone. Cas9 mouse-derived zygotes have the potential to facilitate the creation of genetically modified animals carrying the Cas9 transgene, enabling repeatable genome engineering and the production of Cas9 transgene-free mice.

  6. Temporary Vascular Occlusion by Rapid Reverse Phase Polymer: A Preliminary In Vitro Study of Retrograde Injection

    PubMed Central

    Dregelid, Einar

    2012-01-01

    During vascular surgical operations, there is a need for a simpler and more reliable method of temporary arterial occlusion than those currently employed, especially of heavily calcified arteries. A thermosensitive polymer, LeGoo (LG) (Pluromed, Woburn, MA), has been used successfully for temporary vascular occlusion. It has hitherto been injected by a cannula that has been introduced into the artery to be occluded, here henceforth called the “cannulation method.” Injection into arterial ostia without cannulation, using an injection device that arrests blood flow during the injection, here henceforth called “a retrograde method” may enable temporary hemostasis when ostial stenoses render it impossible to inject LG using the cannulation method. The objective of the present study was to study the feasibility of a retrograde method and to compare it with the cannulation method in an in vitro model, incorporating a narrow orifice to simulate ostial stenosis, using tap water at 37°C instead of blood. The retrograde method of LG injection, using a modified paediatric Foley catheter, turned out to be feasible to produce a durable LG plug more reliably, at higher water pressure and with less deep LG injection than with the cannulation method. PMID:22888352

  7. Automatic vetting of planet candidates from ground based surveys: Machine learning with NGTS

    NASA Astrophysics Data System (ADS)

    Armstrong, David J.; Günther, Maximilian N.; McCormac, James; Smith, Alexis M. S.; Bayliss, Daniel; Bouchy, François; Burleigh, Matthew R.; Casewell, Sarah; Eigmüller, Philipp; Gillen, Edward; Goad, Michael R.; Hodgkin, Simon T.; Jenkins, James S.; Louden, Tom; Metrailler, Lionel; Pollacco, Don; Poppenhaeger, Katja; Queloz, Didier; Raynard, Liam; Rauer, Heike; Udry, Stéphane; Walker, Simon R.; Watson, Christopher A.; West, Richard G.; Wheatley, Peter J.

    2018-05-01

    State of the art exoplanet transit surveys are producing ever increasing quantities of data. To make the best use of this resource, in detecting interesting planetary systems or in determining accurate planetary population statistics, requires new automated methods. Here we describe a machine learning algorithm that forms an integral part of the pipeline for the NGTS transit survey, demonstrating the efficacy of machine learning in selecting planetary candidates from multi-night ground based survey data. Our method uses a combination of random forests and self-organising-maps to rank planetary candidates, achieving an AUC score of 97.6% in ranking 12368 injected planets against 27496 false positives in the NGTS data. We build on past examples by using injected transit signals to form a training set, a necessary development for applying similar methods to upcoming surveys. We also make the autovet code used to implement the algorithm publicly accessible. autovet is designed to perform machine learned vetting of planetary candidates, and can utilise a variety of methods. The apparent robustness of machine learning techniques, whether on space-based or the qualitatively different ground-based data, highlights their importance to future surveys such as TESS and PLATO and the need to better understand their advantages and pitfalls in an exoplanetary context.

  8. Flow-injection chemiluminescence method for the determination of chloramphenicol based on luminol-sodium periodate order-transform second-chemiluminescence reaction.

    PubMed

    Zhuang, Ya-Feng; Zhu, Sheng-Nan; Wei, Wei; Li, Jie-Li

    2011-01-01

    A new chemiluminescence (CL) reaction was observed when chloramphenicol solution was injected into the mixture after the end of the reaction of alkaline luminol and sodium periodate or sodium periodate was injected into the reaction mixture of chloramphenicol and alkaline luminol. This reaction is described as an order-transform second-chemiluminescence (OTSCL) reaction. The OTSCL method combined with a flow-injection technique was applied to the determination of chloramphenicol. The optimum conditions for the order-transform second-chemiluminescence emission were investigated. A mechanism for OTSCL has been proposed on the basis of the chemiluminescence kinetic characteristics, the UV-visible spectra and the chemiluminescent spectra. Under optimal experimental conditions, the CL response is proportional to the concentration of chloramphenicol over the range 5.0 × 10(-7)-5.0 × 10(-5) mol/L with a correlation coefficient of 0.9969 and a detection limit of 6.0 × 10(-8) mol/L (3σ). The relative standard deviation (RSD) for 11 repeated determinations of 5.0 × 10(-6) mol/L chloramphenicol is 1.7%. The method has been applied to the determination of chloramphenicol in pharmaceutical samples with satisfactory results. Copyright © 2011 John Wiley & Sons, Ltd.

  9. Optimization and evaluation of metal injection molding by using X-ray tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Shidi; Zhang, Ruijie; Qu, Xuanhui, E-mail: quxh@ustb.edu.cn

    2015-06-15

    6061 aluminum alloy and 316L stainless steel green bodies were obtained by using different injection parameters (injection pressure, speed and temperature). After injection process, the green bodies were scanned by X-ray tomography. The projection and reconstruction images show the different kinds of defects obtained by the improper injection parameters. Then, 3D rendering of the Al alloy green bodies was used to demonstrate the spatial morphology characteristics of the serious defects. Based on the scanned and calculated results, it is convenient to obtain the proper injection parameters for the Al alloy. Then, reasons of the defect formation were discussed. During moldmore » filling, the serious defects mainly formed in the case of low injection temperature and high injection speed. According to the gray value distribution of projection image, a threshold gray value was obtained to evaluate whether the quality of green body can meet the desired standard. The proper injection parameters of 316L stainless steel can be obtained efficiently by using the method of analyzing the Al alloy injection. - Highlights: • Different types of defects in green bodies were scanned by using X-ray tomography. • Reasons of the defect formation were discussed. • Optimization of the injection parameters can be simplified greatly by the way of X-ray tomography. • Evaluation standard of the injection process can be obtained by using the gray value distribution of projection image.« less

  10. Double-cross hydrostatic pressure sample injection for chip CE: variable sample plug volume and minimum number of electrodes.

    PubMed

    Luo, Yong; Wu, Dapeng; Zeng, Shaojiang; Gai, Hongwei; Long, Zhicheng; Shen, Zheng; Dai, Zhongpeng; Qin, Jianhua; Lin, Bingcheng

    2006-09-01

    A novel sample injection method for chip CE was presented. This injection method uses hydrostatic pressure, generated by emptying the sample waste reservoir, for sample loading and electrokinetic force for dispensing. The injection was performed on a double-cross microchip. One cross, created by the sample and separation channels, is used for formation of a sample plug. Another cross, formed by the sample and controlling channels, is used for plug control. By varying the electric field in the controlling channel, the sample plug volume can be linearly adjusted. Hydrostatic pressure takes advantage of its ease of generation on a microfluidic chip, without any electrode or external pressure pump, thus allowing a sample injection with a minimum number of electrodes. The potential of this injection method was demonstrated by a four-separation-channel chip CE system. In this system, parallel sample separation can be achieved with only two electrodes, which is otherwise impossible with conventional injection methods. Hydrostatic pressure maintains the sample composition during the sample loading, allowing the injection to be free of injection bias.

  11. EM reconstruction of dual isotope PET using staggered injections and prompt gamma positron emitters

    PubMed Central

    Andreyev, Andriy; Sitek, Arkadiusz; Celler, Anna

    2014-01-01

    Purpose: The aim of dual isotope positron emission tomography (DIPET) is to create two separate images of two coinjected PET radiotracers. DIPET shortens the duration of the study, reduces patient discomfort, and produces perfectly coregistered images compared to the case when two radiotracers would be imaged independently (sequential PET studies). Reconstruction of data from such simultaneous acquisition of two PET radiotracers is difficult because positron decay of any isotope creates only 511 keV photons; therefore, the isotopes cannot be differentiated based on the detected energy. Methods: Recently, the authors have proposed a DIPET technique that uses a combination of radiotracer A which is a pure positron emitter (such as 18F or 11C) and radiotracer B in which positron decay is accompanied by the emission of a high-energy (HE) prompt gamma (such as 38K or 60Cu). Events that are detected as triple coincidences of HE gammas with the corresponding two 511 keV photons allow the authors to identify the lines-of-response (LORs) of isotope B. These LORs are used to separate the two intertwined distributions, using a dedicated image reconstruction algorithm. In this work the authors propose a new version of the DIPET EM-based reconstruction algorithm that allows the authors to include an additional, independent estimate of radiotracer A distribution which may be obtained if radioisotopes are administered using a staggered injections method. In this work the method is tested on simple simulations of static PET acquisitions. Results: The authors’ experiments performed using Monte-Carlo simulations with static acquisitions demonstrate that the combined method provides better results (crosstalk errors decrease by up to 50%) than the positron-gamma DIPET method or staggered injections alone. Conclusions: The authors demonstrate that the authors’ new EM algorithm which combines information from triple coincidences with prompt gammas and staggered injections improves the accuracy of DIPET reconstructions for static acquisitions so they reach almost the benchmark level calculated for perfectly separated tracers. PMID:24506645

  12. Three-dimensional electrical impedance tomography based on the complete electrode model.

    PubMed

    Vauhkonen, P J; Vauhkonen, M; Savolainen, T; Kaipio, J P

    1999-09-01

    In electrical impedance tomography an approximation for the internal resistivity distribution is computed based on the knowledge of the injected currents and measured voltages on the surface of the body. It is often assumed that the injected currents are confined to the two-dimensional (2-D) electrode plane and the reconstruction is based on 2-D assumptions. However, the currents spread out in three dimensions and, therefore, off-plane structures have significant effect on the reconstructed images. In this paper we propose a finite element-based method for the reconstruction of three-dimensional resistivity distributions. The proposed method is based on the so-called complete electrode model that takes into account the presence of the electrodes and the contact impedances. Both the forward and the inverse problems are discussed and results from static and dynamic (difference) reconstructions with real measurement data are given. It is shown that in phantom experiments with accurate finite element computations it is possible to obtain static images that are comparable with difference images that are reconstructed from the same object with the empty (saline filled) tank as a reference.

  13. Intra-lymph node injection of biodegradable polymer particles.

    PubMed

    Andorko, James I; Tostanoski, Lisa H; Solano, Eduardo; Mukhamedova, Maryam; Jewell, Christopher M

    2014-01-02

    Generation of adaptive immune response relies on efficient drainage or trafficking of antigen to lymph nodes for processing and presentation of these foreign molecules to T and B lymphocytes. Lymph nodes have thus become critical targets for new vaccines and immunotherapies. A recent strategy for targeting these tissues is direct lymph node injection of soluble vaccine components, and clinical trials involving this technique have been promising. Several biomaterial strategies have also been investigated to improve lymph node targeting, for example, tuning particle size for optimal drainage of biomaterial vaccine particles. In this paper we present a new method that combines direct lymph node injection with biodegradable polymer particles that can be laden with antigen, adjuvant, or other vaccine components. In this method polymeric microparticles or nanoparticles are synthesized by a modified double emulsion protocol incorporating lipid stabilizers. Particle properties (e.g. size, cargo loading) are confirmed by laser diffraction and fluorescent microscopy, respectively. Mouse lymph nodes are then identified by peripheral injection of a nontoxic tracer dye that allows visualization of the target injection site and subsequent deposition of polymer particles in lymph nodes. This technique allows direct control over the doses and combinations of biomaterials and vaccine components delivered to lymph nodes and could be harnessed in the development of new biomaterial-based vaccines.

  14. Physicochemical characterization and an injection formulation study of water insoluble ZCVI₄-2, a novel NO-donor anticancer compound.

    PubMed

    Gao, Yuan; Li, Li; Zhang, Jianjun; Su, Feng; Gong, Zhenhua; Lai, Yisheng; Zhang, Yihua

    2012-07-01

    ZCVI(4)-2 was a novel nitric oxide-releasing glycosyl derivative of oleanolic acid that displayed strong cytotoxicity selectively against human hepatocellular carcinoma in vitro and in vivo. In this study, ZCVI(4)-2 was characterized by FT-IR spectroscopy, differential scanning calorimetry, powder X-ray diffractometry, Raman spectroscopy, hygroscopicity and stability. A high performance liquid chromatography method was also established for the quantitative determination of solubility and additional stability profile of ZCVI(4)-2. ZCVI(4)-2 was found to be an amorphous and stable solid with low solubility of less than 10 μg/mL. Based on the solubilization tests that included methods of cosolvency and micellization, the solution mixture of 5% Solutol HS-15, 5% 1, 2-propylene glycol and 5% anhydrous ethanol was determined to be the system for the preparation of the ZCVI(4)-2 early injection solution. The effect of pH, temperature, light and injectable isotonic glucose or NaCl solution on ZCVI(4)-2 injection was also investigated. Good stability was observed at all testing conditions. Under the conditions studied, the NO-releasing rate and amount of ZCVI(4)-2 from the early injection solution in rat plasma demonstrated a promising therapeutic efficacy while maintaining a good safety profile.

  15. Method for minimizing decarburization and other high temperature oxygen reactions in a plasma sprayed material

    DOEpatents

    Lenling, William J.; Henfling, Joseph A.; Smith, Mark F.

    1993-06-08

    A method is disclosed for spray coating material which employs a plasma gun that has a cathode, an anode, an arc gas inlet, a first powder injection port, and a second powder injection port. A suitable arc gas is introduced through the arc gas inlet, and ionization of the arc gas between the cathode and the anode forms a plasma. The plasma is directed to emenate from an open-ended chamber defined by the boundary of the anode. A coating is deposited upon a base metal part by suspending a binder powder within a carrier gas that is fed into the plasma through the first powder injection port; a material subject to degradation by high temperature oxygen reactions is suspended within a carrier gas that is fed into the plasma through the second injection port. The material fed through the second injection port experiences a cooler portion of the plasma and has a shorter dwell time within the plasma to minimize high temperature oxygen reactions. The material of the first port and the material of the second port intermingle within the plasma to form a uniform coating having constituent percentages related to the powder-feed rates of the materials through the respective ports.

  16. Solution mining systems and methods for treating hydrocarbon containing formations

    DOEpatents

    Vinegar, Harold J [Bellaire, TX; de Rouffignac, Eric Pierre [Rijswijk, NL; Schoeling, Lanny Gene [Katy, TX

    2009-07-14

    A method for treating an oil shale formation comprising nahcolite is disclosed. The method includes providing a first fluid to a portion of the formation through at least two injection wells. A second fluid is produced from the portion through at least one injection well until at least two injection wells are interconnected such that fluid can flow between the two injection wells. The second fluid includes at least some nahcolite dissolved in the first fluid. The first fluid is injected through one of the interconnected injection wells. The second fluid is produced from at least one of the interconnected injection wells. Heat is provided from one or more heaters to the formation to heat the formation. Hydrocarbon fluids are produced from the formation.

  17. Design of a Coupled Thermoresponsive Hydrogel and Robotic System for Postinfarct Biomaterial Injection Therapy.

    PubMed

    Zhu, Yang; Wood, Nathan A; Fok, Kevin; Yoshizumi, Tomo; Park, Dae Woo; Jiang, Hongbin; Schwartzman, David S; Zenati, Marco A; Uchibori, Takafumi; Wagner, William R; Riviere, Cameron N

    2016-09-01

    In preclinical testing, ventricular wall injection of hydrogels has been shown to be effective in modulating ventricular remodeling and preserving cardiac function. For some approaches, early-stage clinical trials are under way. The hydrogel delivery method varies, with minimally invasive approaches being preferred. Endocardial injections carry a risk of hydrogel regurgitation into the circulation, and precise injection patterning is a challenge. An epicardial approach with a thermally gelling hydrogel through the subxiphoid pathway overcomes these disadvantages. A relatively stiff, thermally responsive, injectable hydrogel based on N-isopropylacrylamide and N-vinylpyrrolidone (VP gel) was synthesized and characterized. VP gel thermal behavior was tuned to couple with a transepicardial injection robot, incorporating a cooling feature to achieve injectability. Ventricular wall injections of the optimized VP gel have been performed ex vivo and on beating porcine hearts. Thermal transition temperature, viscosity, and gelling time for the VP gel were manipulated by altering N-vinylpyrrolidone content. The target parameters for cooling in the robotic system were chosen by thermal modeling to support smooth, repeated injections on an ex vivo heart. Injections at predefined locations and depth were confirmed in an infarcted porcine model. A coupled thermoresponsive hydrogel and robotic injection system incorporating a temperature-controlled injectate line was capable of targeted injections and amenable to use with a subxiphoid transepicardial approach for hydrogel injection after myocardial infarction. The confirmation of precise location and depth injections would facilitate a patient-specific planning strategy to optimize injection patterning to maximize the mechanical benefits of hydrogel placement. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Administration of Injectable Vitamin K Orally.

    PubMed

    Afanasjeva, Janna

    2017-10-01

    Background: Vitamin K, or phytonadione, is available in both injectable and oral formulations. Oral vitamin K is available as 5-mg tablets, but the key drawbacks for using vitamin K tablets consist of availability of only 1 dose strength and recent tripling of the product's cost over a 2-year period. An interest exists for utilization of injectable vitamin K via oral route. Method: A literature search was performed on April 26, 2017, to identify any studies describing the use of injectable vitamin K for oral administration. The search involved PubMed and Embase and utilized various combinations of keywords vitamin K , phytonadione , IV , intravenous , injectable , and oral . The results were limited to studies that discussed oral administration of injectable vitamin K. The efficacy of the injectable preparation of vitamin K administered orally was explored in 6 studies and one cost-savings project. Results: Based on the available literature, the administration of injectable vitamin K via oral route is effective and safe. Injectable vitamin K for oral administration can be prepared as an undiluted solution or as a compounded solution. These 2 formulations have different beyond-use dates depending on ingredients used. Conclusion: Information on efficacy and stability of injectable vitamin K formulations prepared for oral administration provides an additional option for health care systems when vitamin K tablets are unavailable or cost-prohibitive to use.

  19. Enduring consequences from the War on Drugs: How policing practices impact HIV risk among people who inject drugs in Baltimore City

    PubMed Central

    Flath, Natalie; Tobin, Karin; King, Kelly; Lee, Alexandra; Latkin, Carl

    2017-01-01

    Background Neighborhood-level characteristics, including police activity, are associated with HIV and Hepatitis C injection risk-behaviors among people who inject drugs (PWID). However, the pathways through which these neighborhood perceptions shape individual-level HIV risk behaviors are unclear. This study helps to explain perceived behaviors between perceived neighborhood police activity and HIV injection risk behavior (i.e., injection syringe/tool sharing in the previous six months). Methods A sample of (n=366) PWIDs who self-reported recent use were recruited using community-based outreach methods in Baltimore, Maryland. Neighborhood police perceptions were assessed by asking participants whether they would (1) be more likely to ask others to share injection tools in the context of heightened police activity; and (2) be less likely to carry syringes with them due to fear of arrest. Poisson regression with robust variance was used to identify statistical relationships. Recent police encounters, frequency of heroin injection, and socio-demographic characteristics were controlled for in the model. Results Neighborhood police perceptions shaped injection-risk behavior. Half of the sample (49%) reported an aversion of carrying personal syringes, due to fear of arrest. Those who agreed they would be more likely to ask others to share injection equipment in the context of heightened police activity were more likely to share syringes (21% versus 3%, p<0.01). Adjusted models showed that syringe sharing was independently associated with asking to borrow equipment in neighborhoods with perceived heightened police activity (aPR 2.22 95% CI 1.7, 3.0). Conclusion This study sheds light on how police perceptions may influence injection risk behavior. While these relationships require further elucidation, this study suggests that public health interventions aiming to reduce HIV risk would benefit from improving community- police relationships. PMID:28318343

  20. Mathematical modeling of the in-mold coating process for injection-molded thermoplastic parts

    NASA Astrophysics Data System (ADS)

    Chen, Xu

    In-Mold Coating (IMC) has been successfully used for many years for exterior body panels made from compression molded Sheet Molding Compound (SMC). The coating material is a single component reactive fluid, designed to improve the surface quality of SMC moldings in terms of functional and cosmetic properties. When injected onto a cured SMC part, IMC cures and bonds to provide a pain-like surface. Because of its distinct advantages, IMC is being considered for application to injection molded thermoplastic parts. For a successful in mold coating operation, there are two key issues related to the flow of the coating. First, the injection nozzle should be located such that the thermoplastic substrate is totally covered and the potential for air trapping is minimized. The selected location should be cosmetically acceptable since it most likely will leave a mark on the coated surface. The nozzle location also needs to be accessible for easy of maintenance. Secondly, the hydraulic force generated by the coating injection pressure should not exceed the available clamping tonnage. If the clamping force is exceeded, coating leakage will occur. In this study, mathematical models for IMC flow on the compressible thermoplastic substrate have been developed. Finite Difference Method (FDM) is first used to solve the 1 dimensional (1D) IMC flow problem. In order to investigate the application of Control Volume based Finite Element Method (CV/FEM) to more complicated two dimensional IMC flow, that method is first evaluated by solving the 1D IMC flow problem. An analytical solution, which can be obtained when a linear relationship between the coating thickness and coating injection pressure is assumed, is used to verify the numerical results. The mathematical models for the 2 dimensional (2D) IMC flow are based on the generalized Hele-Shaw approximation. It has been found experimentally that the power law viscosity model adequately predicts the rheological behavior of the coating. The compressibility of the substrate is modeled by the 2-domain Tait PVT equation. CV/FEM is used to solve the discretized governing equations. A computer code has been developed to predict the fill pattern of the coating and the injection pressure. A number of experiments have been conducted to verify the numerical predictions of the computer code. It has been found both numerically and experimentally that the substrate thickness plays a significant role on the IMC fill pattern.

  1. Web-Based Interactive 3D Visualization as a Tool for Improved Anatomy Learning

    ERIC Educational Resources Information Center

    Petersson, Helge; Sinkvist, David; Wang, Chunliang; Smedby, Orjan

    2009-01-01

    Despite a long tradition, conventional anatomy education based on dissection is declining. This study tested a new virtual reality (VR) technique for anatomy learning based on virtual contrast injection. The aim was to assess whether students value this new three-dimensional (3D) visualization method as a learning tool and what value they gain…

  2. Physiologically-Based Pharmacokinetic Modelling to Inform Development of Intramuscular Long Acting Nanoformulations for HIV

    PubMed Central

    Rajoli, Rajith KR; Back, David J; Rannard, Steve; Meyers, Caren Freel; Flexner, Charles; Owen, Andrew; Siccardi, Marco

    2014-01-01

    Background and Objectives Antiretrovirals (ARVs) are currently used for the treatment and prevention of HIV infection. Poor adherence and low tolerability of some existing oral formulations can hinder their efficacy. Long-acting (LA) injectable nanoformulations could help address these complications by simplifying ARV administration. The aim of this study is to inform the optimisation of intramuscular LA formulations for eight ARVs through physiologically-based pharmacokinetic (PBPK) modelling. Methods A whole-body PBPK model was constructed using mathematical descriptions of molecular, physiological and anatomical processes defining pharmacokinetics. These models were validated against available clinical data and subsequently used to predict the pharmacokinetics of injectable LA formulations Results The predictions suggest that monthly intramuscular injections are possible for dolutegravir, efavirenz, emtricitabine, raltegravir, rilpivirine and tenofovir provided that technological challenges to control release rate can be addressed. Conclusions These data may help inform the target product profiles for LA ARV reformulation strategies. PMID:25523214

  3. Loss Factor Estimation Using the Impulse Response Decay Method on a Stiffened Structure

    NASA Technical Reports Server (NTRS)

    Cabell, Randolph; Schiller, Noah; Allen, Albert; Moeller, Mark

    2009-01-01

    High-frequency vibroacoustic modeling is typically performed using energy-based techniques such as Statistical Energy Analysis (SEA). Energy models require an estimate of the internal damping loss factor. Unfortunately, the loss factor is difficult to estimate analytically, and experimental methods such as the power injection method can require extensive measurements over the structure of interest. This paper discusses the implications of estimating damping loss factors using the impulse response decay method (IRDM) from a limited set of response measurements. An automated procedure for implementing IRDM is described and then evaluated using data from a finite element model of a stiffened, curved panel. Estimated loss factors are compared with loss factors computed using a power injection method and a manual curve fit. The paper discusses the sensitivity of the IRDM loss factor estimates to damping of connected subsystems and the number and location of points in the measurement ensemble.

  4. A New Treatment Strategy for Inactivating Algae in Ballast Water Based on Multi-Trial Injections of Chlorine

    PubMed Central

    Sun, Jinyang; Wang, Junsheng; Pan, Xinxiang; Yuan, Haichao

    2015-01-01

    Ships’ ballast water can carry aquatic organisms into foreign ecosystems. In our previous studies, a concept using ion exchange membrane electrolysis to treat ballast water has been proven. In addition to other substantial approaches, a new strategy for inactivating algae is proposed based on the developed ballast water treatment system. In the new strategy, the means of multi-trial injection with small doses of electrolytic products is applied for inactivating algae. To demonstrate the performance of the new strategy, contrast experiments between new strategies and routine processes were conducted. Four algae species including Chlorella vulgaris, Platymonas subcordiformis, Prorocentrum micans and Karenia mikimotoi were chosen as samples. The different experimental parameters are studied including the injection times and doses of electrolytic products. Compared with the conventional one trial injection method, mortality rate time (MRT) and available chlorine concentration can be saved up to about 84% and 40%, respectively, under the application of the new strategy. The proposed new approach has great potential in practical ballast water treatment. Furthermore, the strategy is also helpful for deep insight of mechanism of algal tolerance. PMID:26068239

  5. Research on the Injection Performance of a Novel Lubricating Device Based on Piezoelectric Micro-Jet Technology

    NASA Astrophysics Data System (ADS)

    Li, Kai; Liu, Jun-kao; Chen, Wei-shan; Ye, Le; Zhang, Lu

    2016-08-01

    In order to solve the problem of lubrication failure in bearing systems, a novel lubricating device which can achieve drop-on-demand lubrication is proposed based on piezoelectric micro-jet technology. The injection performance of the novel piezoelectric micro-jet lubricating device are analyzed in this paper. The influences of the fluid-structure interaction to the working frequency are studied by comparing the results of tests with simulations. A method used to forecast the working frequency of the micro-jet is proved to be available. A velocity inlet boundary model at the nozzle is derived under the assumption that the lubricating oil cannot be pressed. Combined with this model, the influences of density, dynamic viscosity and surface tension of the lubricating oil on the injection performance are discussed according to the simulation results. An experiment on the injection performance of the micro-jet for ejecting lubricating oil with different dilution ratios is performed. The recommended excitations are given for ejecting lubricating oil with different properties by analyzing the results.

  6. Flow-injection chemiluminescence determination of acetylsalicylic acid based on its enhancing effect on the lucigenin–hydrogen peroxide system.

    PubMed

    Wabaidur, S M; Alam, S M; Alothmana, Z A; Eldesokya, Gaber

    2014-09-01

    A sensitive flow-injection chemiluminescence method for the determination of acetylsalicylic acid is described. It is based on the enhanced chemiluminescent emission of the alkaline lucigenin–H2O2 system by acetylsalicylic acid. The difference in chemiluminescent intensity of alkaline lucigenin–H2O2 in the presence of acetylsalicylic acid from that in the absence of acetylsalicylic acid was linear at acetylsalicylic acid concentrations in the range of 0.0029–47.37 μg/mL, with detection and quantification limits of 0.0011 and 0.0029 μg/mL, respectively. The correlation coefficient of the working curve was 0.9983. The relative standard deviation (n = 10) for 25 μg/mL acetylsalicylic acid is 1.95%. All experimental parameters were optimized. The method was successfully applied to the determination of acetylsalicylic acid in pharmaceutical preparations. The recovery results obtained by the method were satisfactory.

  7. [Monitoring method of extraction process for Schisandrae Chinensis Fructus based on near infrared spectroscopy and multivariate statistical process control].

    PubMed

    Xu, Min; Zhang, Lei; Yue, Hong-Shui; Pang, Hong-Wei; Ye, Zheng-Liang; Ding, Li

    2017-10-01

    To establish an on-line monitoring method for extraction process of Schisandrae Chinensis Fructus, the formula medicinal material of Yiqi Fumai lyophilized injection by combining near infrared spectroscopy with multi-variable data analysis technology. The multivariate statistical process control (MSPC) model was established based on 5 normal batches in production and 2 test batches were monitored by PC scores, DModX and Hotelling T2 control charts. The results showed that MSPC model had a good monitoring ability for the extraction process. The application of the MSPC model to actual production process could effectively achieve on-line monitoring for extraction process of Schisandrae Chinensis Fructus, and can reflect the change of material properties in the production process in real time. This established process monitoring method could provide reference for the application of process analysis technology in the process quality control of traditional Chinese medicine injections. Copyright© by the Chinese Pharmaceutical Association.

  8. Methods To Assess Shear-Thinning Hydrogels for Application As Injectable Biomaterials

    PubMed Central

    2017-01-01

    Injectable hydrogels have gained popularity as a vehicle for the delivery of cells, growth factors, and other molecules to localize and improve their retention at the injection site, as well as for the mechanical bulking of tissues. However, there are many factors, such as viscosity, storage and loss moduli, and injection force, to consider when evaluating hydrogels for such applications. There are now numerous tools that can be used to quantitatively assess these factors, including for shear-thinning hydrogels because their properties change under mechanical load. Here, we describe relevant rheological tests and ways to measure injection force using a force sensor or a mechanical testing machine toward the evaluation of injectable hydrogels. Injectable, shear-thinning hydrogels can be used in a variety of clinical applications, and as an example we focus on methods for injection into the heart, where an understanding of injection properties and mechanical forces is imperative for consistent hydrogel delivery and retention. We discuss methods for delivery of hydrogels to mouse, rat, and pig hearts in models of myocardial infarction, and compare methods of tissue postprocessing for hydrogel preservation. Our intent is that the methods described herein can be helpful in the design and assessment of shear-thinning hydrogels for widespread biomedical applications. PMID:29250593

  9. Micro-CT in situ study of carbonate rock microstructural evolution for geologic CO2 storage

    NASA Astrophysics Data System (ADS)

    Zheng, Y.; Yang, Y.; Rogowska, M.; Gundlach, C.

    2017-09-01

    To achieve the 2°C target made in the 2016 Paris Agreement, it is essential to reduce the emission of CO2 into the atmosphere. Carbon Capture and Storage (CCS) has been given increasing importance over the last decade. One of the suggested methods for CCS is to inject CO2 into geologic settings such as the carbonate reservoirs in the North Sea. The final aim of our project is to find out how to control the evolution of petrophysical parameters during CO2 injection using an optimal combination of flow rate, injection pressure and chemical composition of the influent. The first step to achieve this is to find a suitable condition to create a stable 3D space in carbonate rock by injecting liquid to prepare space for the later CO2 injection. Micro-CT imaging is a non-destructive 3D method that can be used to study the property changes of carbonate rocks during and after CO2 injection. The advance in lab source based micro-CT has made it capable of in situ experiments. We used a commercial bench top micro-CT (Zeiss Versa XRM410) to study the microstructure changes of chalk during liquid injection. Flexible temporal CT resolution is essential in this study because that the time scales of coupled physical and chemical processes can be very different. The results validated the feasibility of using a bench top CT system with a pressure cell to monitor the mesoscale multiphase interactions in chalk.

  10. Modeling GPR data to interpret porosity and DNAPL saturations for calibration of a 3-D multiphase flow simulation

    USGS Publications Warehouse

    Sneddon, Kristen W.; Powers, Michael H.; Johnson, Raymond H.; Poeter, Eileen P.

    2002-01-01

    Dense nonaqueous phase liquids (DNAPLs) are a pervasive and persistent category of groundwater contamination. In an effort to better understand their unique subsurface behavior, a controlled and carefully monitored injection of PCE (perchloroethylene), a typical DNAPL, was performed in conjunction with the University of Waterloo at Canadian Forces Base Borden in 1991. Of the various geophysical methods used to monitor the migration of injected PCE, the U.S. Geological Survey collected 500-MHz ground penetrating radar (GPR) data. These data are used in determining calibration parameters for a multiphase flow simulation. GPR data were acquired over time on a fixed two-dimensional surficial grid as the DNAPL was injected into the subsurface. Emphasis is on the method of determining DNAPL saturation values from this time-lapse GPR data set. Interactive full-waveform GPR modeling of regularized field traces resolves relative dielectric permittivity versus depth profiles for pre-injection and later-time data. Modeled values are end members in recursive calculations of the Bruggeman-Hanai-Sen (BHS) mixing formula, yielding interpreted pre-injection porosity and post-injection DNAPL saturation values. The resulting interpreted physical properties of porosity and DNAPL saturation of the Borden test cell, defined on a grid spacing of 50 cm with 1-cm depth resolution, are used as observations for calibration of a 3-D multiphase flow simulation. Calculated values of DNAPL saturation in the subsurface at 14 and 22 hours after the start of injection, from both the GPR and the multiphase flow modeling, are interpolated volumetrically and presented for visual comparison.

  11. Injectable contraceptive sales at licensed chemical seller shops in ghana: access and reported use in rural and periurban communities.

    PubMed

    Lebetkin, Elena; Orr, Tracy; Dzasi, Kafui; Keyes, Emily; Shelus, Victoria; Mensah, Stephen; Nagai, Henry; Stanback, John

    2014-03-01

    Most women in Ghana obtain oral contraceptives and condoms from shops run by licensed chemical sellers, but such shops are not legally permitted to sell the country's most widely used method, the injectable. Allowing shops to sell the injectable could increase access to and use of the method. In 2012-2013, semistructured telephone interviews were conducted among convenience samples of 94 licensed chemical seller shop operators in two districts who were trained to sell the injectable and of 298 women who purchased the method from these shops. Follow-up interviews were conducted with 92 clients approximately three months after their initial injectable purchase. Ninety-seven percent of shop operators reported selling the injectable, and 94% felt sufficiently trained to provide family planning methods and services. Virtually all sellers (99%) referred clients to a hospital or health facility for injection; none provided injections themselves. Fifty-six percent of injectable clients were new family planning users. Of those who completed a follow-up interview, 79% had purchased the injectable again from a shop. Virtually all clients (97%) reported getting their injection at the health facility to which they were referred by the seller. Women cited trust, convenience and commodities being in stock as key reasons for purchasing from a shop. Licensed chemical seller shop operators can safely sell the injectable and refer clients to health facilities for screening, counseling and injection.

  12. Topology optimization applied to the design of cooling channels for plastic injection

    NASA Astrophysics Data System (ADS)

    Muñoz, D. A.; Arango, J. P.; González, C.; Puerto, E.; Garzón, M.

    2018-04-01

    In this paper, topology optimization is applied to design cooling channels in a mold of structural steel. The problem was implemented in COMSOL multiphysics, where two physics were coupled, heat transfer and solid mechanics. The optimization objective is to maximize the conduction heat flux in the mold and minimize the deformations when the plastic is injected. In order to find an optimal geometry for this objective, a density-based method was implemented into the nonlinear program (NLP) for which feasible results were found.

  13. Allogeneic Mesenchymal Stem Cells in Combination with Hyaluronic Acid for the Treatment of Osteoarthritis in Rabbits.

    PubMed

    Chiang, En-Rung; Ma, Hsiao-Li; Wang, Jung-Pan; Liu, Chien-Lin; Chen, Tain-Hsiung; Hung, Shih-Chieh

    2016-01-01

    Mesenchymal stem cell (MSC)-based therapies may aid in the repair of articular cartilage defects. The purpose of this study was to investigate the effects of intraarticular injection of allogeneic MSCs in an in vivo anterior cruciate ligament transection (ACLT) model of osteoarthritis in rabbits. Allogeneic bone marrow-derived MSCs were isolated and cultured under hypoxia (1% O2). After 8 weeks following ACLT, MSCs suspended in hyaluronic acid (HA) were injected into the knees, and the contralateral knees were injected with HA alone. Additional controls consisted of a sham operation group as well as an untreated osteoarthritis group. The tissues were analyzed by macroscopic examination as well as histologic and immunohistochemical methods at 6 and 12 weeks post-transplantation. At 6 and 12 weeks, the joint surface showed less cartilage loss and surface abrasion after MSC injection as compared to the tissues receiving HA injection alone. Significantly better histological scores and cartilage content were observed with the MSC transplantation. Furthermore, engraftment of allogenic MSCs were evident in surface cartilage. Thus, injection of the allogeneic MSCs reduced the progression of osteoarthritis in vivo.

  14. Measured emittance dependence on injection method in laser plasma accelerators

    NASA Astrophysics Data System (ADS)

    Barber, Samuel; van Tilborg, Jeroen; Schroeder, Carl; Lehe, Remi; Tsai, Hai-En; Swanson, Kelly; Steinke, Sven; Nakamura, Kei; Geddes, Cameron; Benedetti, Carlo; Esarey, Eric; Leemans, Wim

    2017-10-01

    The success of many laser plasma accelerator (LPA) based applications relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot transverse emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock induced density down-ramp injection. Notably, the measurements reveal that ionization injection results in significantly higher emittance. With the down-ramp injection configuration, emittances less than 1 micron at spectral charge densities up to 2 pC/MeV were measured. This work was supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the NSF under Grant No. PHY-1415596, by the U.S. DOE NNSA, DNN R&D (NA22), and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  15. Optimization of Injection Molding Parameters for HDPE/TiO₂ Nanocomposites Fabrication with Multiple Performance Characteristics Using the Taguchi Method and Grey Relational Analysis.

    PubMed

    Pervez, Hifsa; Mozumder, Mohammad S; Mourad, Abdel-Hamid I

    2016-08-22

    The current study presents an investigation on the optimization of injection molding parameters of HDPE/TiO₂ nanocomposites using grey relational analysis with the Taguchi method. Four control factors, including filler concentration (i.e., TiO₂), barrel temperature, residence time and holding time, were chosen at three different levels of each. Mechanical properties, such as yield strength, Young's modulus and elongation, were selected as the performance targets. Nine experimental runs were carried out based on the Taguchi L₉ orthogonal array, and the data were processed according to the grey relational steps. The optimal process parameters were found based on the average responses of the grey relational grades, and the ideal operating conditions were found to be a filler concentration of 5 wt % TiO₂, a barrel temperature of 225 °C, a residence time of 30 min and a holding time of 20 s. Moreover, analysis of variance (ANOVA) has also been applied to identify the most significant factor, and the percentage of TiO₂ nanoparticles was found to have the most significant effect on the properties of the HDPE/TiO₂ nanocomposites fabricated through the injection molding process.

  16. INTERNATIONAL CONFERENCE ON SEMICONDUCTOR INJECTION LASERS SELCO-87: Determination of the quantum efficiency of InGaAsP/InP double heterostructures from spontaneous emission measurements

    NASA Astrophysics Data System (ADS)

    Rheinländer, B.; Anton, A.; Heilmann, R.; Oelgart, G.; Gottschalch, V.

    1988-11-01

    A method was developed for determination of the suitability of epitaxial InGaAsP/InP double heterostructures in fabrication of ridge-waveguide lasers. The method is based on determination of the quantum efficiency of electroluminescence.

  17. Combining CO2 sequestration and CH4 production by means of guest exchange in a gas hydrate reservoir: two pilot scale experiments

    NASA Astrophysics Data System (ADS)

    Heeschen, Katja U.; Spangenberg, Erik; Schicks, Judith M.; Deusner, Christian; Priegnitz, Mike; Strauch, Bettina; Bigalke, Nikolaus; Luzi-Helbing, Manja; Kossel, Elke; Haeckel, Matthias; Wang, Yi

    2017-04-01

    Methane (CH4) hydrates are considered as a player in the field of energy supply and - if applied as such - as a possible sink for the greenhouse gas carbon dioxide (CO2). Next to the more conventional production methods depressurization and thermal stimulation, an extraction of CH4 by means of CO2 injection is investigated. The method is based on the chemical potential gradient between the CH4 hydrate phase and the injected CO2 phase. Results from small-scale laboratory experiments on the replacement method indicate recovery ratios of up to 66% CH4 but also encounter major discrepancies in conversion rates. So far it has not been demonstrated with certainty that the process rates are sufficient for an energy and cost effective production of CH4 with a concurrent sequestration of CO2. In a co-operation of GFZ and GEOMAR we used LARS (Large Scale Reservoir Simulator) to investigate the CO2-CH4-replacement method combined with thermal stimulation. LARS accommodates a sample volume of 210 l and allows for the simulation of in situ conditions typically found in gas hydrate reservoirs. Based on the sample size, diverse transport mechanisms could be simulated, which are assumed to significantly alter process yields. Temperature and pressure data complemented by a high resolution electrical resistivity tomography (ERT), gas chromatography, and flow measurements serve to interpret the experiments. In two experiments 50 kg heated CO2 was injected into sediments with CH4 hydrate saturations of 50%. While in the first experiment the CO2 was injected discontinuously in a so called "huff'n puff" manner, the second experiment saw a continuous injection. Conditions within LARS were set to 13 MPa and 8˚ C, which allow for stability of pure CO2 and CH4 hydrates as well as mixed hydrates. The CO2 was heated and entered the sediment sample with temperatures of approximately 30˚ C. In this presentation we will discuss the results from the large-scale experiments and compare them with data from small-scale experiments.

  18. Digital Twin concept for smart injection molding

    NASA Astrophysics Data System (ADS)

    Liau, Y.; Lee, H.; Ryu, K.

    2018-03-01

    Injection molding industry has evolved over decades and became the most common method to manufacture plastic parts. Monitoring and improvement in the injection molding industry are usually performed separately in each stage, i.e. mold design, mold making and injection molding process. However, in order to make a breakthrough and survive in the industrial revolution, all the stages in injection molding need to be linked and communicated with each other. Any changes in one stage will cause a certain effect in other stage because there is a correlation between each other. Hence, the simulation should not only based on the input of historical data, but it also needs to include the current condition of equipment and prediction of future events in other stages to make the responsive decision. This can be achieved by implementing the concept of Digital Twin that models the entire process as a virtual model and enables bidirectional control with the physical process. This paper presented types of data and technology required to build the Digital Twin for the injection molding industry. The concept includes Digital Twin of each stage and integration of these Digital Twin model as a thoroughgoing model of the injection molding industry.

  19. Application of direct-injection detector integrated with the multi-pumping flow system to chemiluminescence determination of the total polyphenol index.

    PubMed

    Nalewajko-Sieliwoniuk, Edyta; Iwanowicz, Magdalena; Kalinowski, Sławomir; Kojło, Anatol

    2016-03-10

    In this work, we present a novel chemiluminescence (CL) method based on direct-injection detector (DID) integrated with the multi-pumping flow system (MPFS) to chemiluminescence determination of the total polyphenol index. In this flow system, the sample and the reagents are injected directly into the cone-shaped detection cell placed in front of the photomultiplier window. Such construction of the detection chamber allows for fast measurement of the CL signal in stopped-flow conditions immediately after mixing the reagents. The proposed DID-CL-MPFS method is based on the chemiluminescence of nanocolloidal manganese(IV)-hexametaphosphate-ethanol system. The application of ethanol as a sensitizer, eliminated the use of carcinogenic formaldehyde. Under the optimized experimental conditions, the chemiluminescence intensities are proportional to the concentration of gallic acid in the range from 5 to 350 ng mL(-1). The DID-CL-MPFS method offers a number of advantages, including low limit of detection (0.80 ng mL(-1)), high precision (RSD = 3.3%) and high sample throughput (144 samples h(-1)) as well as low consumption of reagents, energy and low waste generation. The proposed method has been successfully applied to determine the total polyphenol index (expressed as gallic acid equivalent) in a variety of plant-derived food samples (wine, tea, coffee, fruit and vegetable juices, herbs, spices). Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Theoretical aspects for estimating anisotropic saturated hydraulic conductivity from in-well or direct-push probe injection tests in uniform media

    NASA Astrophysics Data System (ADS)

    Klammler, Harald; Layton, Leif; Nemer, Bassel; Hatfield, Kirk; Mohseni, Ana

    2017-06-01

    Hydraulic conductivity and its anisotropy are fundamental aquifer properties for groundwater flow and transport modeling. Current in-well or direct-push field measurement techniques allow for relatively quick determination of general conductivity profiles with depth. However, capabilities for identifying local scale conductivities in the horizontal and vertical directions are very limited. Here, we develop the theoretical basis for estimating horizontal and vertical conductivities from different types of steady-state single-well/probe injection tests under saturated conditions and in the absence of a well skin. We explore existing solutions and a recent semi-analytical solution approach to the flow problem under the assumption that the aquifer is locally homogeneous. The methods are based on the collection of an additional piece of information in the form of a second injection (or recirculation) test at a same location, or in the form of an additional head or flow observation along the well/probe. Results are represented in dimensionless charts for partial validation against approximate solutions and for practical application to test interpretation. The charts further allow for optimization of a test configuration to maximize sensitivity to anisotropy ratio. The two methods most sensitive to anisotropy are found to be (1) subsequent injection from a lateral screen and from the bottom of an otherwise cased borehole, and (2) single injection from a lateral screen with an additional head observation along the casing. Results may also be relevant for attributing consistent divergences in conductivity measurements from different testing methods applied at a same site or location to the potential effects of anisotropy. Some practical aspects are discussed and references are made to existing methods, which appear easily compatible with the proposed procedures.

  1. Modeling of time-lapse multi-scale seismic monitoring of CO2 injected into a fault zone to enhance the characterization of permeability in enhanced geothermal systems

    NASA Astrophysics Data System (ADS)

    Zhang, R.; Borgia, A.; Daley, T. M.; Oldenburg, C. M.; Jung, Y.; Lee, K. J.; Doughty, C.; Altundas, B.; Chugunov, N.; Ramakrishnan, T. S.

    2017-12-01

    Subsurface permeable faults and fracture networks play a critical role for enhanced geothermal systems (EGS) by providing conduits for fluid flow. Characterization of the permeable flow paths before and after stimulation is necessary to evaluate and optimize energy extraction. To provide insight into the feasibility of using CO2 as a contrast agent to enhance fault characterization by seismic methods, we model seismic monitoring of supercritical CO2 (scCO2) injected into a fault. During the CO2 injection, the original brine is replaced by scCO2, which leads to variations in geophysical properties of the formation. To explore the technical feasibility of the approach, we present modeling results for different time-lapse seismic methods including surface seismic, vertical seismic profiling (VSP), and a cross-well survey. We simulate the injection and production of CO2 into a normal fault in a system based on the Brady's geothermal field and model pressure and saturation variations in the fault zone using TOUGH2-ECO2N. The simulation results provide changing fluid properties during the injection, such as saturation and salinity changes, which allow us to estimate corresponding changes in seismic properties of the fault and the formation. We model the response of the system to active seismic monitoring in time-lapse mode using an anisotropic finite difference method with modifications for fracture compliance. Results to date show that even narrow fault and fracture zones filled with CO2 can be better detected using the VSP and cross-well survey geometry, while it would be difficult to image the CO2 plume by using surface seismic methods.

  2. Medroxyprogesterone Injection

    MedlinePlus

    ... Medroxyprogesterone injection is a very effective method of birth control but does not prevent the spread of human ... you have been using a different method of birth control and are switching to medroxyprogesterone injection, your doctor ...

  3. The Optimisation of Processing Condition for Injected Mould Polypropylene-Nanoclay-Gigantochloa Scortechinii based on Melt Flow Index

    NASA Astrophysics Data System (ADS)

    Othman, M. H.; Rosli, M. S.; Hasan, S.; Amin, A. M.; Hashim, M. Y.; Marwah, O. M. F.; Amin, S. Y. M.

    2018-03-01

    The fundamental knowledge of flow behaviour is essential in producing various plastic parts injection moulding process. Moreover, the adaptation of advanced polymer-nanocomposites such as polypropylene-nanoclay with natural fibres, for instance Gigantochloa Scortechinii may boost up the mechanical properties of the parts. Therefore, this project was proposed with the objective to optimise the processing condition of injected mould polypropylene-nanoclay-Gigantochloa Scortechini fibres based on the flow behaviour, which was melt flow index. At first, Gigantochloa Scortechinii fibres have to be preheated at temperature 120°C and then mixed with polypropylene, maleic anhydride modified polypropylene oligomers (PPgMA) and nanoclay by using Brabender Plastograph machine. Next, forms of pellets were produced from the samples by using Granulator machine for use in the injection moulding process. The design of experiments that was used in the injection moulding process was Taguchi Method Orthogonal Array -L934. Melt Flow Index (MF) was selected as the response. Based on the results, the value of MFI increased when the fiber content increase from 0% to 3%, which was 17.78 g/10min to 22.07 g/10min and decreased from 3% to 6%, which was 22.07 g/10min to 20.05 g/10min and 3%, which gives the highest value of MFI. Based on the signal to ratio analysis, the most influential parameter that affects the value of MFI was the melt temperature. The optimum parameter for 3% were 170°C melt temperature, 35% packing pressure, 30% screw speed and 3 second filling time.

  4. Probabilistic 3-D time-lapse inversion of magnetotelluric data: application to an enhanced geothermal system

    NASA Astrophysics Data System (ADS)

    Rosas-Carbajal, M.; Linde, N.; Peacock, J.; Zyserman, F. I.; Kalscheuer, T.; Thiel, S.

    2015-12-01

    Surface-based monitoring of mass transfer caused by injections and extractions in deep boreholes is crucial to maximize oil, gas and geothermal production. Inductive electromagnetic methods, such as magnetotellurics, are appealing for these applications due to their large penetration depths and sensitivity to changes in fluid conductivity and fracture connectivity. In this work, we propose a 3-D Markov chain Monte Carlo inversion of time-lapse magnetotelluric data to image mass transfer following a saline fluid injection. The inversion estimates the posterior probability density function of the resulting plume, and thereby quantifies model uncertainty. To decrease computation times, we base the parametrization on a reduced Legendre moment decomposition of the plume. A synthetic test shows that our methodology is effective when the electrical resistivity structure prior to the injection is well known. The centre of mass and spread of the plume are well retrieved. We then apply our inversion strategy to an injection experiment in an enhanced geothermal system at Paralana, South Australia, and compare it to a 3-D deterministic time-lapse inversion. The latter retrieves resistivity changes that are more shallow than the actual injection interval, whereas the probabilistic inversion retrieves plumes that are located at the correct depths and oriented in a preferential north-south direction. To explain the time-lapse data, the inversion requires unrealistically large resistivity changes with respect to the base model. We suggest that this is partly explained by unaccounted subsurface heterogeneities in the base model from which time-lapse changes are inferred.

  5. Probabilistic 3-D time-lapse inversion of magnetotelluric data: Application to an enhanced geothermal system

    USGS Publications Warehouse

    Rosas-Carbajal, Marina; Linde, Nicolas; Peacock, Jared R.; Zyserman, F. I.; Kalscheuer, Thomas; Thiel, Stephan

    2015-01-01

    Surface-based monitoring of mass transfer caused by injections and extractions in deep boreholes is crucial to maximize oil, gas and geothermal production. Inductive electromagnetic methods, such as magnetotellurics, are appealing for these applications due to their large penetration depths and sensitivity to changes in fluid conductivity and fracture connectivity. In this work, we propose a 3-D Markov chain Monte Carlo inversion of time-lapse magnetotelluric data to image mass transfer following a saline fluid injection. The inversion estimates the posterior probability density function of the resulting plume, and thereby quantifies model uncertainty. To decrease computation times, we base the parametrization on a reduced Legendre moment decomposition of the plume. A synthetic test shows that our methodology is effective when the electrical resistivity structure prior to the injection is well known. The centre of mass and spread of the plume are well retrieved.We then apply our inversion strategy to an injection experiment in an enhanced geothermal system at Paralana, South Australia, and compare it to a 3-D deterministic time-lapse inversion. The latter retrieves resistivity changes that are more shallow than the actual injection interval, whereas the probabilistic inversion retrieves plumes that are located at the correct depths and oriented in a preferential north-south direction. To explain the time-lapse data, the inversion requires unrealistically large resistivity changes with respect to the base model. We suggest that this is partly explained by unaccounted subsurface heterogeneities in the base model from which time-lapse changes are inferred.

  6. A Prospective Method to Increase Oil Recovery in Waxy-Shallow Reservoir

    NASA Astrophysics Data System (ADS)

    Hidayat, F.; Abdurrahman, M.

    2018-02-01

    Waxy oil has been the main characteristics of The X field. Initial screening criteria studies indicated that cyclic steam stimulation (CSS) would be the optimum option because favorable reservoir condition. Based on this method we would like to know how much oil gain and the effect of steam for the stimulated and surrounding well. The injection of steam was done for 7 days followed by 14 days of soaking period. 39,000 liter of Marine fuel oil was used to generate steam for stimulation with an average produce steam quality about 80%. Average of 255 MMBTU of steam was injected each day with total steam injected was about 1.7 BBTU. The oil production was increased four times from 5 bopd into 21 bopd. Proper well candidate and high permeability are some reason for this method successfully increase oil production. Additional heat from steam reduced the damage near wellbore due to wax deposition. This is verifying by increasing productivity index from 3 bbl/psi to 4 bbl/psi. From results and observation data, this method can be a platform for typical shallow depth reservoir with high paraffinic content especially other reservoir in Sihapas formation.

  7. Stabilized single-injection inactivated polio vaccine elicits a strong neutralizing immune response.

    PubMed

    Tzeng, Stephany Y; McHugh, Kevin J; Behrens, Adam M; Rose, Sviatlana; Sugarman, James L; Ferber, Shiran; Langer, Robert; Jaklenec, Ana

    2018-05-21

    Vaccination in the developing world is hampered by limited patient access, which prevents individuals from receiving the multiple injections necessary for protective immunity. Here, we developed an injectable microparticle formulation of the inactivated polio vaccine (IPV) that releases multiple pulses of stable antigen over time. To accomplish this, we established an IPV stabilization strategy using cationic polymers for pH modulation to enhance traditional small-molecule-based stabilization methods. We investigated the mechanism of this strategy and showed that it was broadly applicable to all three antigens in IPV. Our lead formulations released two bursts of IPV 1 month apart, mimicking a typical vaccination schedule in the developing world. One injection of the controlled-release formulations elicited a similar or better neutralizing response in rats, considered the correlate of protection in humans, than multiple injections of liquid vaccine. This single-administration vaccine strategy has the potential to improve vaccine coverage in the developing world. Copyright © 2018 the Author(s). Published by PNAS.

  8. Stabilized single-injection inactivated polio vaccine elicits a strong neutralizing immune response

    PubMed Central

    Tzeng, Stephany Y.; McHugh, Kevin J.; Behrens, Adam M.; Rose, Sviatlana; Sugarman, James L.; Ferber, Shiran; Jaklenec, Ana

    2018-01-01

    Vaccination in the developing world is hampered by limited patient access, which prevents individuals from receiving the multiple injections necessary for protective immunity. Here, we developed an injectable microparticle formulation of the inactivated polio vaccine (IPV) that releases multiple pulses of stable antigen over time. To accomplish this, we established an IPV stabilization strategy using cationic polymers for pH modulation to enhance traditional small-molecule–based stabilization methods. We investigated the mechanism of this strategy and showed that it was broadly applicable to all three antigens in IPV. Our lead formulations released two bursts of IPV 1 month apart, mimicking a typical vaccination schedule in the developing world. One injection of the controlled-release formulations elicited a similar or better neutralizing response in rats, considered the correlate of protection in humans, than multiple injections of liquid vaccine. This single-administration vaccine strategy has the potential to improve vaccine coverage in the developing world. PMID:29784798

  9. Parameter Optimization Of Natural Hydroxyapatite/SS316l Via Metal Injection Molding (MIM)

    NASA Astrophysics Data System (ADS)

    Mustafa, N.; Ibrahim1, M. H. I.; Amin, A. M.; Asmawi, R.

    2017-01-01

    Metal injection molding (MIM) are well known as a worldwide application of powder injection molding (PIM) where as applied the shaping concept and the beneficial of plastic injection molding but develops the applications to various high performance metals and alloys, plus metal matrix composites and ceramics. This study investigates the strength of green part by using stainless steel 316L/ Natural hydroxyapatite composite as a feedstock. Stainless steel 316L (SS316L) was mixed with Natural hydroxyapatite (NHAP) by adding 40 wt. % Low Density Polyethylene and 60 %wt. Palm Stearin as a binder system at 63 wt. % powder loading consist of 90 % wt. of SS316 L and 10 wt. % NHAP prepared thru critical powder volume percentage (CPVC). Taguchi method was functional as a tool in determining the optimum green strength for Metal Injection Molding (MIM) parameters. The green strength was optimized with 4 significant injection parameter such as Injection temperature (A), Mold temperature (B), Pressure (C) and Speed (D) were selected throughout screening process. An orthogonal array of L9 (3)4 was conducted. The optimum injection parameters for highest green strength were established at A1, B2, C0 and D1 and where as calculated based on Signal to Noise Ratio.

  10. [Metabonomic phenotype of "formula corresponding to pattern types" based on "qi and yin deficiency pattern" of myocardial ischemia rat model].

    PubMed

    Yan, Bei; A, Ji-Ye; Hao, Hai-Ping; Wang, Guang-Ji; Liu, Lin-Sheng; Zha, Wei-Bin; Zhang, Ying; Gu, Sheng-Hua

    2011-08-01

    In order to explore the scientific connotation of "Fangzhengduiying (formula corresponding to pattern types)", "Qiyinliangxuzheng (Qi and Yin deficiency pattern)" of myocardial ischemia rat model and GC-TOF/MS based metabonomic method were used for comparing the effects of Sheng-mai injection, Salvia injection and propranolol in the present study. After data processing and pattern recognition, Sheng-mai injection showed better efficacy than the other two drugs in accordance with not only visual observation from PLS-DA scores plots but also the number of abnormal endogenous compounds restored to the normal level. Further studies showed that Sheng-mai injection could normalize the level of plasma endothelin-1, the index related to cardiovascular diseases and sleep disorders, which verified the results of metabonomics. Finally, the regulated metabolites and related metabolic pathways were analyzed, and it was supposed that the effects of Sheng-mai injection involved in the alternation of energy metabolism, lipid metabolism, amino acids metabolism, and so on. These findings provided scientific evidence to Shengmai "Fang" used for "Qi and Yin deficiency pattern" correspondingly, indicating that metabonomics has great potential in traditional Chinese medical research, which provides a novel approach and way to modernization of traditional Chinese medicine.

  11. Validation of microinjection methods for generating knockout mice by CRISPR/Cas-mediated genome engineering.

    PubMed

    Horii, Takuro; Arai, Yuji; Yamazaki, Miho; Morita, Sumiyo; Kimura, Mika; Itoh, Masahiro; Abe, Yumiko; Hatada, Izuho

    2014-03-28

    The CRISPR/Cas system, in which the Cas9 endonuclease and a guide RNA complementary to the target are sufficient for RNA-guided cleavage of the target DNA, is a powerful new approach recently developed for targeted gene disruption in various animal models. However, there is little verification of microinjection methods for generating knockout mice using this approach. Here, we report the verification of microinjection methods of the CRISPR/Cas system. We compared three methods for injection: (1) injection of DNA into the pronucleus, (2) injection of RNA into the pronucleus, and (3) injection of RNA into the cytoplasm. We found that injection of RNA into the cytoplasm was the most efficient method in terms of the numbers of viable blastocyst stage embryos and full-term pups generated. This method also showed the best overall knockout efficiency.

  12. Uptake of wheel-filtration among clients of a supervised injecting facility: Can structured education work?

    PubMed

    Steele, Maureen; Silins, Edmund; Flaherty, Ian; Hiley, Sarah; van Breda, Nick; Jauncey, Marianne

    2018-01-01

    Wheel-filtration of pharmaceutical opioid tablets is a recognised harm reduction strategy, but uptake of the practice among people who inject drugs is low. The study aimed to: (i) examine perceptions of filtration practices; (ii) provide structured education on wheel-filtration; and (iii) assess uptake of the practice. Frequent opioid tablet injectors (n = 30) attending a supervised injecting facility in Sydney, Australia, received hands-on instruction on wheel-filtration based on recommended practice. Pre-education, post-education and follow-up questionnaires were administered. Wheel-filtration was generally regarded as better than cotton-filtration (the typical method) in terms of perceived effects on health, ease of use and overall drug effect. Sixty-eight percent of those who said they would try wheel-filtration after the education had actually done so. Of those who usually used cotton-filtration, over half (60%) had used wheel-filtration two weeks later. Uptake of safer preparation methods for pharmaceutical opioid tablets increases after structured education in wheel-filtration. Findings suggest that SIFs are an effective site for this kind of education. Supervised injecting facility workers are uniquely positioned to provide harm reduction education at the time of injection. [Steele M, Silins E, Flaherty I, Hiley S, van Breda N, Jauncey M. Uptake of wheel-filtration among clients of a supervised injecting facility: Can structured education work? Drug Alcohol Rev 2018;37:116-120]. © 2017 Australasian Professional Society on Alcohol and other Drugs.

  13. Modelling induced seismicity due to fluid injection

    NASA Astrophysics Data System (ADS)

    Murphy, S.; O'Brien, G. S.; Bean, C. J.; McCloskey, J.; Nalbant, S. S.

    2011-12-01

    Injection of fluid into the subsurface alters the stress in the crust and can induce earthquakes. The science of assessing the risk of induced seismicity from such ventures is still in its infancy despite public concern. We plan to use a fault network model in which stress perturbations due to fluid injection induce earthquakes. We will use this model to investigate the role different operational and geological factors play in increasing seismicity in a fault system due to fluid injection. The model is based on a quasi-dynamic relationship between stress and slip coupled with a rate and state fiction law. This allows us to model slip on fault interfaces over long periods of time (i.e. years to 100's years). With the use of the rate and state friction law the nature of stress release during slipping can be altered through variation of the frictional parameters. Both seismic and aseismic slip can therefore be simulated. In order to add heterogeneity along the fault plane a fractal variation in the frictional parameters is used. Fluid injection is simulated using the lattice Boltzmann method whereby pore pressure diffuses throughout a permeable layer from the point of injection. The stress perturbation this causes on the surrounding fault system is calculated using a quasi-static solution for slip dislocation in an elastic half space. From this model we can generate slip histories and seismicity catalogues covering 100's of years for predefined fault networks near fluid injection sites. Given that rupture is a highly non-linear process, comparison between models with different input parameters (e.g. fault network statistics and injection rates) will be based on system wide features (such as the Gutenberg-Richter b-values), rather than specific seismic events. Our ultimate aim is that our model produces seismic catalogues similar to those observed over real injection sites. Such validation would pave the way to probabilistic estimation of reactivation risk for injection sites using such models. Preliminary results from this model will be presented.

  14. Comparison of Candida Albicans Adherence to Conventional Acrylic Denture Base Materials and Injection Molding Acrylic Materials

    PubMed Central

    Aslanimehr, Masoomeh; Rezvani, Shirin; Mahmoudi, Ali; Moosavi, Najmeh

    2017-01-01

    Statement of the Problem: Candida species are believed to play an important role in initiation and progression of denture stomatitis. The type of the denture material also influences the adhesion of candida and development of stomatitis. Purpose: The aim of this study was comparing the adherence of candida albicans to the conventional and injection molding acrylic denture base materials. Materials and Method: Twenty injection molding and 20 conventional pressure pack acrylic discs (10×10×2 mm) were prepared according to their manufacturer’s instructions. Immediately before the study, samples were placed in sterile water for 3 days to remove residual monomers. The samples were then sterilized using an ultraviolet light unit for 10 minutes. 1×108 Cfu/ml suspension of candida albicans ATCC-10231 was prepared from 48 h cultured organism on sabouraud dextrose agar plates incubated at 37oC. 100 μL of this suspension was placed on the surface of each disk. After being incubated at 37oC for 1 hour, the samples were washed with normal saline to remove non-adherent cells. Attached cells were counted using the colony count method after shaking at 3000 rmp for 20 seconds. Finally, each group was tested for 108 times and the data were statistically analyzed by t-test. Results: Quantitative analysis revealed that differences in colony count average of candida albicans adherence to conventional acrylic materials (8.3×103) comparing to injection molding acrylic resins (6×103) were statistically significant (p<0.001). Conclusion: Significant reduction of candida albicans adherence to the injection acrylic resin materials makes them valuable for patients with high risk of denture stomatitis. PMID:28280761

  15. Calculation method of water injection forward modeling and inversion process in oilfield water injection network

    NASA Astrophysics Data System (ADS)

    Liu, Long; Liu, Wei

    2018-04-01

    A forward modeling and inversion algorithm is adopted in order to determine the water injection plan in the oilfield water injection network. The main idea of the algorithm is shown as follows: firstly, the oilfield water injection network is inversely calculated. The pumping station demand flow is calculated. Then, forward modeling calculation is carried out for judging whether all water injection wells meet the requirements of injection allocation or not. If all water injection wells meet the requirements of injection allocation, calculation is stopped, otherwise the demand injection allocation flow rate of certain step size is reduced aiming at water injection wells which do not meet requirements, and next iterative operation is started. It is not necessary to list the algorithm into water injection network system algorithm, which can be realized easily. Iterative method is used, which is suitable for computer programming. Experimental result shows that the algorithm is fast and accurate.

  16. The determination of sulfite levels and its oxidation in plant leaves.

    PubMed

    Brychkova, Galina; Yarmolinsky, Dmitry; Fluhr, Robert; Sagi, Moshe

    2012-07-01

    Sulfur is the sixth most abundant element in life and an important building block of proteins and cellular metabolites. Plants like bacteria can synthesize their sulfur-containing biomolecules from sulfate, where sulfite is an intermediate of the sulfur assimilation pathway. Above a certain threshold SO(2)/sulfite is cytotoxic and is rapidly metabolized to avoid damage. However, the existing data show considerable differences in basal sulfite levels both between species and apparent discrepancies in measured levels in the same species. In order to resolve this question we employed a sulfite detection method using chicken sulfite oxidase and developed an independent enzymatic assay, based on the specific detection of sulfite by sulfite reductase and compared those measurements to a modified colorimetric fuchsin-based method, specific for sulfite detection. We show here that when properly used the sulfite levels detected by the three methods can yield identical results. Furthermore, to examine the capacity of the plant to detoxify sulfite we injected sub-lethal sulfite solutions (yet, several folds higher than the basal levels) into Arabidopsis and tomato leaves and monitored the excess sulfite turnover. Within 3h of sulfite injection, more than 80% of the injected sulfite in Arabidopsis and 91% in tomato were oxidized to sulfate, demonstrating the high capacity of the sulfite oxidation mechanism/s in plants. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. The use of cell-sheet technique eliminates arrhythmogenicity of skeletal myoblast-based therapy to the heart with enhanced therapeutic effects.

    PubMed

    Narita, Takuya; Shintani, Yasunori; Ikebe, Chiho; Kaneko, Masahiro; Harada, Narumi; Tshuma, Nomathamsanqa; Takahashi, Kunihiko; Campbell, Niall G; Coppen, Steven R; Yashiro, Kenta; Sawa, Yoshiki; Suzuki, Ken

    2013-09-20

    Clinical application of skeletal myoblast transplantation has been curtailed due to arrhythmogenicity and inconsistent therapeutic benefits observed in previous studies. However, these issues may be solved by the use of a new cell-delivery mode. It is now possible to generate "cell-sheets" using temperature-responsive dishes without artificial scaffolds. This study aimed to validate the safety and efficacy of epicardial placement of myoblast-sheets (myoblast-sheet therapy) in treating heart failure. After coronary artery ligation in rats, the same numbers of syngeneic myoblasts were transplanted by intramyocardial injection or cell-sheet placement. Continuous radio-telemetry monitoring detected increased ventricular arrhythmias, including ventricular tachycardia, after intramyocardial injection compared to the sham-control, while these were abolished in myoblast-sheet therapy. This effect was conjunct with avoidance of islet-like cell-cluster formation that disrupts electrical conduction, and with prevention of increased arrhythmogenic substrates due to exaggerated inflammation. Persistent ectopic donor cells were found in the lung only after intramyocardial injection, strengthening the improved safety of myoblast-sheet therapy. In addition, myoblast-sheet therapy enhanced cardiac function, corresponding to a 9.2-fold increase in donor cell survival, compared to intramyocardial injection. Both methods achieved reduced infarct size, decreased fibrosis, attenuated cardiomyocyte hypertrophy, and increased neovascular formation, in association with myocardial upregulation of a group of relevant molecules. The pattern of these beneficial changes was similar between two methods, but the degree was more substantial after myoblast-sheet therapy. The cell-sheet technique enhanced safety and therapeutic efficacy of myoblast-based therapy, compared to the current method, thereby paving the way for clinical application. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  18. Deformational injection rate measuring method

    NASA Astrophysics Data System (ADS)

    Marčič, Milan

    2002-09-01

    After completing the diesel engine endurance testing, we detected various traces of thermal load on the walls of combustion chambers located in the engine pistons. The engines were fitted with ω combustion chambers. The thermal load of different intensity levels occurred where the spray of fuel, fuel vapor, and air interacted with the combustion chamber wall. The uneven thermal load distribution of the combustion chamber wall results from varying injection rates in each injection nozzle hole. The most widely applied controlling methods so far for injection rate measurement, such as the Zeuch and Bosch concepts, allow measurement of only the total injection rate in multihole nozzles, without providing any indication whatsoever of the injection rate differences in individual injection nozzle holes. The new deformational measuring method described in the article allows the injection rate to be measured in each hole of the multihole nozzle. The results of the measurements using this method showed that the differences occurred in injection rates of individual injection nozzle holes. These differences may be the cause of various thermal loads on the combustion chamber walls. The criterion for injection rate is the deformation of the membrane due to an increase in the fuel quantity in the measuring space and due to the pressure waves resulting from the fuel being injected into the measuring space. The membrane deformation is measured using strain gauges, glued to the membrane and forming the Wheatstone's bridge. We devoted special attention to the temperature compensation of the Wheatstone's bridge and the membrane, heated up during the measurements.

  19. Interpretaion of synthetic seismic time-lapse monitoring data for Korea CCS project based on the acoustic-elastic coupled inversion

    NASA Astrophysics Data System (ADS)

    Oh, J.; Min, D.; Kim, W.; Huh, C.; Kang, S.

    2012-12-01

    Recently, the CCS (Carbon Capture and Storage) is one of the promising methods to reduce the CO2 emission. To evaluate the success of the CCS project, various geophysical monitoring techniques have been applied. Among them, the time-lapse seismic monitoring is one of the effective methods to investigate the migration of CO2 plume. To monitor the injected CO2 plume accurately, it is needed to interpret seismic monitoring data using not only the imaging technique but also the full waveform inversion, because subsurface material properties can be estimated through the inversion. However, previous works for interpreting seismic monitoring data are mainly based on the imaging technique. In this study, we perform the frequency-domain full waveform inversion for synthetic data obtained by the acoustic-elastic coupled modeling for the geological model made after Ulleung Basin, which is one of the CO2 storage prospects in Korea. We suppose the injection layer is located in fault-related anticlines in the Dolgorae Deformed Belt and, for more realistic situation, we contaminate the synthetic monitoring data with random noise and outliers. We perform the time-lapse full waveform inversion in two scenarios. One scenario is that the injected CO2 plume migrates within the injection layer and is stably captured. The other scenario is that the injected CO2 plume leaks through the weak part of the cap rock. Using the inverted P- and S-wave velocities and Poisson's ratio, we were able to detect the migration of the injected CO2 plume. Acknowledgment This work was financially supported by the Brain Korea 21 project of Energy Systems Engineering, the "Development of Technology for CO2 Marine Geological Storage" program funded by the Ministry of Land, Transport and Maritime Affairs (MLTM) of Korea and the Korea CCS R&D Center (KCRC) grant funded by the Korea government (Ministry of Education, Science and Technology) (No. 2012-0008926).

  20. SU-F-T-10: Validation of ELP Dosimetry Using PRESAGE Dosimeter: Feasibility Test and Practical Considerations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lambson, K; Lafata, K; Miles, D

    Purpose: To validate the use of a PRESAGE dosimeter as a method to quantitatively measure dose distributions of injectable brachytherapy based on elastin-like polypeptide (ELP) nanoparticles. PRESAGE is a solid, transparent polyurethane-based dosimeter whose dose is proportional to a change in optical density, making it useful for visualizing the dose from a radionuclide-tagged-ELP injection. Methods: A PRESAGE dosimeter was designed to simulate an ELP injection. To calibrate, cuvette samples from the batch of PRESAGE were exposed to varying levels of radiation from 0–35.9Gy applied via a linear accelerator, then placed into a spectrophotometer to obtain the optical density change asmore » a function of dose. A pre-optical-CT scan was acquired of the phantom to obtain a baseline tomographic optical density. A 1cc saline solution of I-125 tagged-ELP with and activity concentration of 1mCi/cc was injected into the phantom and left for five days. After five days, the ELP was removed and the cavity cleaned of all remaining radioactive material. Post tomographic optical images were acquired to obtain a differential optical density dataset. Results: Initial results after the 5-day exposure revealed an opaque white film that resembled the volume of the ELP solution injected into the phantom. We think this is possibly due to the saline solution diffusing into the PRESAGE and causing a change in the index of refraction at this shallow depth. Therefore, initially the optical scanner yielded inconclusive results. After several more days, the saline seemed to have evaporated out of the injection site and the ELP dose distribution was visible via color change in the dosimeter. Conclusion: We have created the first experimental design to measure the dose distribution of I-125-tagged-ELP. The PRESAGE formulation proves to be a feasible option for such measurements. Future experimental measurements need to be obtained to further characterize ELP dosimetry.« less

  1. Oil field experiments of microbial improved oil recovery in Vyngapour, West Siberia, Russia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murygina, V.P.; Mats, A.A.; Arinbasarov, M.U.

    1995-12-31

    Experiments on microbial improved oil recovery (MIOR) have been performed in the Vyngapour oil field in West Siberia for two years. Now, the product of some producing wells of the Vyngapour oil field is 98-99% water cut. The operation of such wells approaches an economic limit. The nutritious composition containing local industry wastes and sources of nitrogen, phosphorus and potassium was pumped into an injection well on the pilot area. This method is called {open_quotes}nutritional flooding.{close_quotes} The mechanism of nutritional flooding is based on intensification of biosynthesis of oil-displacing metabolites by indigenous bacteria and bacteria from food industry wastes inmore » the stratum. 272.5 m{sup 3} of nutritious composition was introduced into the reservoir during the summer of 1993, and 450 m3 of nutritious composition-in 1994. The positive effect of the injections in 1993 showed up in 2-2.5 months and reached its maximum in 7 months after the injections were stopped. By July 1, 1994, 2,268.6 tons of oil was produced over the base variant, and the simultaneous water extraction reduced by 33,902 m{sup 3} as compared with the base variant. The injections in 1994 were carried out on the same pilot area.« less

  2. Insights into the Functional Anatomy Behind the PREEMPT Injection Paradigm: Guidance on Achieving Optimal Outcomes

    PubMed Central

    Silberstein, Stephen D.; Dodick, David W.; Aurora, Sheena K.; Brin, Mitchell F.; Binder, William J.

    2017-01-01

    Objective To provide clinically relevant insights on the identification of the muscles and techniques involved in the safe and effective use of onabotulinumtoxinA for chronic migraine prophylaxis. Background Although guidance on the use of onabotulinumtoxinA for chronic migraine is available, based on the Phase III Research Evaluating Migraine Prophylaxis Therapy (PREEMPT) clinical program, clinical experience has shown that insufficient understanding of the anatomy and function of the head and neck muscles may lead to undesirable outcomes and suboptimal efficacy. Design/Methods Each muscle involved in the standardized PREEMPT injection paradigm is reviewed with a thorough description of each muscle's anatomy (ie, muscle description and location, innervation, vascular supply) and function. Key insights based on clinical experience are also provided to help improve outcomes. Results The identification of the muscles in the PREEMPT injection paradigm should be based on each patient's unique anatomy and injections should be administered using the advised techniques. A thorough examination of the patient prior to treatment is also critical to determine if any preexisting conditions may increase the risk for unwanted outcomes and appropriate expectations should be communicated. Conclusions Thorough knowledge of the functional anatomy of the muscles involved in the standardized PREEMPT injection paradigm is critical to achieve the efficacy and safety observed in clinical trials. In addition, it is important to assess a patient's baseline condition to anticipate the risk for unwanted outcomes that may result from treatment. PMID:28387038

  3. Experimental evaluation of the certification-trail method

    NASA Technical Reports Server (NTRS)

    Sullivan, Gregory F.; Wilson, Dwight S.; Masson, Gerald M.; Itoh, Mamoru; Smith, Warren W.; Kay, Jonathan S.

    1993-01-01

    Certification trails are a recently introduced and promising approach to fault-detection and fault-tolerance. A comprehensive attempt to assess experimentally the performance and overall value of the method is reported. The method is applied to algorithms for the following problems: huffman tree, shortest path, minimum spanning tree, sorting, and convex hull. Our results reveal many cases in which an approach using certification-trails allows for significantly faster overall program execution time than a basic time redundancy-approach. Algorithms for the answer-validation problem for abstract data types were also examined. This kind of problem provides a basis for applying the certification-trail method to wide classes of algorithms. Answer-validation solutions for two types of priority queues were implemented and analyzed. In both cases, the algorithm which performs answer-validation is substantially faster than the original algorithm for computing the answer. Next, a probabilistic model and analysis which enables comparison between the certification-trail method and the time-redundancy approach were presented. The analysis reveals some substantial and sometimes surprising advantages for ther certification-trail method. Finally, the work our group performed on the design and implementation of fault injection testbeds for experimental analysis of the certification trail technique is discussed. This work employs two distinct methodologies, software fault injection (modification of instruction, data, and stack segments of programs on a Sun Sparcstation ELC and on an IBM 386 PC) and hardware fault injection (control, address, and data lines of a Motorola MC68000-based target system pulsed at logical zero/one values). Our results indicate the viability of the certification trail technique. It is also believed that the tools developed provide a solid base for additional exploration.

  4. Determination of dasatinib in the tablet dosage form by ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis.

    PubMed

    Gonzalez, Aroa Garcia; Taraba, Lukáš; Hraníček, Jakub; Kozlík, Petr; Coufal, Pavel

    2017-01-01

    Dasatinib is a novel oral prescription drug proposed for treating adult patients with chronic myeloid leukemia. Three analytical methods, namely ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis, were developed, validated, and compared for determination of the drug in the tablet dosage form. The total analysis time of optimized ultra high performance liquid chromatography and capillary zone electrophoresis methods was 2.0 and 2.2 min, respectively. Direct ultraviolet detection with detection wavelength of 322 nm was employed in both cases. The optimized sequential injection analysis method was based on spectrophotometric detection of dasatinib after a simple colorimetric reaction with folin ciocalteau reagent forming a blue-colored complex with an absorbance maximum at 745 nm. The total analysis time was 2.5 min. The ultra high performance liquid chromatography method provided the lowest detection and quantitation limits and the most precise and accurate results. All three newly developed methods were demonstrated to be specific, linear, sensitive, precise, and accurate, providing results satisfactorily meeting the requirements of the pharmaceutical industry, and can be employed for the routine determination of the active pharmaceutical ingredient in the tablet dosage form. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Flow injection analysis of picric acid explosive using a copper electrode as electrochemical detector.

    PubMed

    Junqueira, João R C; de Araujo, William R; Salles, Maiara O; Paixão, Thiago R L C

    2013-01-30

    A simple and fast electrochemical method for quantitative analysis of picric acid explosive (nitro-explosive) based on its electrochemical reduction at copper surfaces is reported. To achieve a higher sample throughput, the electrochemical sensor was adapted in a flow injection system. Under optimal experimental conditions, the peak current response increases linearly with picric acid concentration over the range of 20-300 μmol L(-1). The repeatability of the electrode response in the flow injection analysis (FIA) configuration was evaluated as 3% (n=10), and the detection limit of the method was estimated to be 6.0 μmol L(-1) (S/N=3). The sample throughput under optimised conditions was estimated to be 550 samples h(-1). Peroxide explosives like triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD) were tested as potential interfering substances for the proposed method, and no significant interference by these explosives was noticed. The proposed method has interesting analytical parameters, environmental applications, and low cost compared with other electroanalytical methods that have been reported for the quantification of picric acid. Additionally, the possibility to develop an in situ device for the detection of picric acid using a disposable sensor was evaluated. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.

  6. Utility of Vibratory Stimulation for Reducing Intraoral Injection Pain.

    PubMed

    Erdogan, Ozgur; Sinsawat, Anatachai; Pawa, Sudeep; Rintanalert, Duangtawan; Vuddhakanok, Suchada

    2018-01-01

    Intraoral local anesthesia injection is often perceived as a painful and anxiety-causing dental procedure. Vibration stimulus is one of the nonpharmacologic methods used to reduce unwanted sensations of local anesthesia injection. This clinical study evaluated the effectiveness of a recently introduced vibratory stimulation device in intraoral local anesthesia administration. Thirty-two subjects underwent 2 maxillary local anesthesia injections in 2 different sessions: 1 with conventional techniques and 1 with the aid of a vibratory stimulation device (DentalVibe). The pain levels were evaluated with a visual analog scale and the Wong-Baker FACES Pain Rating Scale. The subjects were asked to choose the preferred method for future injections. The data were evaluated statistically. There were no significant differences between the 2 injection methods with regard to either pain evaluation method. The preference of the subjects regarding future injection technique was evenly distributed between the groups. The vibratory stimulation device used in this study did not provide any reduction in pain level associated with maxillary infiltration local anesthesia administration.

  7. Longitudinal Trajectories of Ketamine Use among Young Injection Drug Users

    PubMed Central

    Lankenau, Stephen E.; Bloom, Jennifer Jackson; Shin, Charles

    2010-01-01

    Background Ketamine is a dissociative anesthetic that became increasing popular in the club and rave scene in the 1980s and 1990s. Reports surfaced in the late 1990s indicating that ketamine was being injected in several U.S. cities by young injection drug users (IDUs). Since all studies on ketamine injection were cross-sectional, a longitudinal study was undertaken in 2005 to determine: characteristics of young IDUs who continue to inject ketamine; frequency of ketamine injection over an extended time period; risks associated with ongoing ketamine injection; and environmental factors that impact patterns of ketamine use. Methods Young IDUs aged 16 to 29 with a history of injecting ketamine (n=101) were recruited from public locations in Los Angeles and followed during a two-year longitudinal study. A semi-structured instrument captured quantitative and qualitative data on patterns of ketamine injection and other drug use. A statistical model sorted IDUs who completed three or more interviews (n=66) into three groups based upon patterns of ketamine injection at baseline and follow-up. Qualitative analysis focused on detailed case studies within each group. Results IDUs recruited at baseline were typically in their early 20s, male, heterosexual, white, and homeless. Longitudinal injection trajectories included: “Moderates,” who injected ketamine several times per year (n=5); “Occasionals,” who injected ketamine approximately once per year (n=21); and “Abstainers,” who did not inject any ketamine during follow-up (n=40). Findings suggest that ketamine is infrequently injected compared to other drugs such as heroin, cocaine, and methamphetamine. Most IDUs who begin injecting ketamine will stop or curb use due to: negative or ambivalent experiences associated with ketamine; an inability to find the drug due to declining supply; or maturing out of injecting drugs more generally. Conclusion Reducing ketamine injection among young IDUs may best be accomplished by targeting particular groups of IDUs identified in this study, such as homeless youth and homeless travelers. PMID:20138747

  8. Easy and Fast Method for the Determination of Biogenic Amines in Fish and Fish Products with Liquid Chromatography Coupled to Orbitrap Tandem Mass Spectrometry.

    PubMed

    Kaufmann, Anton; Maden, Kathryn

    2018-03-01

    A quantitative method for the determination of biogenic amines was developed. The method is characterized by the virtual absence of sample cleanup and does not require a derivatization reaction. Diluted extracts are centrifuged, filtrated, and directly injected into an ultra-HPLC column, which is coupled to a single-stage high-resolution mass spectrometer (Orbitrap). The chromatography is based on a reversed-phase column and an eluent containing an ion-pairing agent (heptafluorobutyric acid). The high sensitivity of the instrument permits the injection of very diluted extracts, which ensures stable retention times and the virtual absence of signal suppression effects. In addition, the quantification of histamine (a regulated compound) is further aided by the use of an isotopically labeled internal standard. The method was validated for three fish-based matrixes. Both the sample processing and the analytical measurement are very fast; hence, the methodology is ideal for high-throughput work. In addition, the method is significantly more selective than conventional methods (i.e., derivatization followed by LC with UV/fluorescence (FL) detection) for biogenic amines. A comparison showed that LC-UV/FL methods can produce false-positive findings due to coeluting matrix compounds.

  9. Electrically Injected UV-Visible Nanowire Lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, George T.; Li, Changyi; Li, Qiming

    2015-09-01

    There is strong interest in minimizing the volume of lasers to enable ultracompact, low-power, coherent light sources. Nanowires represent an ideal candidate for such nanolasers as stand-alone optical cavities and gain media, and optically pumped nanowire lasing has been demonstrated in several semiconductor systems. Electrically injected nanowire lasers are needed to realize actual working devices but have been elusive due to limitations of current methods to address the requirement for nanowire device heterostructures with high material quality, controlled doping and geometry, low optical loss, and efficient carrier injection. In this project we proposed to demonstrate electrically injected single nanowire lasersmore » emitting in the important UV to visible wavelengths. Our approach to simultaneously address these challenges is based on high quality III-nitride nanowire device heterostructures with precisely controlled geometries and strong gain and mode confinement to minimize lasing thresholds, enabled by a unique top-down nanowire fabrication technique.« less

  10. The Hydrodynamics of Needle-Free Intradermal Jet Injection

    NASA Astrophysics Data System (ADS)

    Simmons, Jonathan; Marston, Jeremy; Fisher, Paul; Broderick, Kate

    2017-11-01

    Needle-free methods of drug delivery circumvent the drawbacks associated with the use of hypodermic needles such as needle-stick injuries, needle-phobia, cross contamination and disposal. Furthermore, pioneering DNA-based vaccines that aim to treat cancer and fight infectious diseases, such as HIV, Ebola and Zika, require precise deposition into the skin to target the immune response producing cells found only in the epidermis and dermis. Intradermal (ID) delivery can be achieved using a needle and the Mantoux technique but this requires a highly skilled technician and so extensive use of DNA vaccines calls for an alternative method of delivery. One option is jet injection which has been employed in mass vaccination programs for intramuscular or subcutaneous delivery and is used by some diabetic patients to inject insulin. In this talk I will present results from our ongoing ex-vivo experimental study into ID jet injection. Ultra-high-speed imaging is used to visualize the process of the jet exiting the nozzle and striking excised skin. A skin bleb grows as liquid is deposited within the skin. I will discuss how the control parameters, such as the rheological profile of the liquid and the stand-off distance, influence the volume of liquid successfully delivered intradermally.

  11. Treatment intensification without improved HbA1c levels in children and adolescents with Type 1 diabetes mellitus.

    PubMed

    Sildorf, S M; Hertel, N T; Thomsen, J; Fredheim, S; Hastrup, H; Pipper, C; Hertz, B; Svensson, J

    2016-04-01

    To examine trends in diabetes treatment in Danish children and adolescents with Type 1 diabetes mellitus, comparing treatment intensity with metabolic outcomes in the population, and to describe the challenges of population-based registries in a clinical setting with rapidly changing treatment methods. This observational study is based on the Danish national population registry of childhood diabetes, which includes 99% of children diagnosed with Type 1 diabetes before the age of 15 years. We included 4527 people diagnosed between 2000 and 2012. Self-monitored blood glucose measurements, insulin injections/boluses, treatment method and metabolic control quantifications were analysed and adjusted for the effects of gender and ethnicity, the combined effect of age, visit year and duration, and for the random effects of individual and hospital settings. Treatment was intensified via an increasing number of self-monitored blood glucose measurements and injections/boluses. More than six injections/boluses and an increased number of self-monitored blood glucose measurements were significantly associated with lower metabolic control. No reduction, however, in the overall mean HbA1c concentration was observed between 2005 [66 mmol/mol (8.2%)] and 2012 [65 mmol/mol (8.1%)]. Changed registration practices in 2009 introduced artificial jumps in data. Intensifying treatment alone does not lead to improved metabolic control in the overall population despite the appearance of lower HbA1c in individuals with a greater number of self-monitored blood glucose measurements and injections/boluses. The contradictory results reflect difficulties in using observational studies to predict results of intervention in the individual. Data collected from population-based registries need to be adjusted continuously to reflect changes in care. © 2015 Diabetes UK.

  12. Rapid determination of isoamyl nitrite in pharmaceutical preparations by flow injection analysis with on-line UV irradiation and luminol chemiluminescence detection.

    PubMed

    Kishikawa, Naoya; Kondo, Naoko; Amponsaa-Karikari, Abena; Kodamatani, Hitoshi; Ohyama, Kaname; Nakashima, Kenichiro; Yamazaki, Shigeo; Kuroda, Naotaka

    2014-02-01

    Isoamyl nitrite is used as a therapeutic reagent for cardiac angina and as an antidote for cyanide poisoning, but it is abused because of its euphoric properties. Therefore, a method to determine isoamyl nitrite is required in many fields, including pharmaceutical and forensic studies. In this study, a simple, rapid and sensitive method for the determination of isoamyl nitrite was developed using a flow injection analysis system equipped with a chemiluminescence detector and on-line photoreactor. This method is based on on-line ultraviolet irradiation of isoamyl nitrite and subsequent luminol chemiluminescence detection without the addition of an oxidant. A linear standard curve was obtained up to 1.0 μM of isoamyl nitrite with a detection limit (blank + 3SD) of 0.03 μM. The method was successfully applied to determine isoamyl nitrite content in pharmaceutical preparations. Copyright © 2013 John Wiley & Sons, Ltd.

  13. Intra-muscular and oral vaccination using a Koi Herpesvirus ORF25 DNA vaccine does not confer protection in common carp (Cyprinus carpio L.).

    PubMed

    Embregts, Carmen W E; Tadmor-Levi, Roni; Veselý, Tomáš; Pokorová, Dagmar; David, Lior; Wiegertjes, Geert F; Forlenza, Maria

    2018-03-19

    Koi Herpes Virus (KHV or Cyprinid Herpesvirus 3, CyHV-3) is among the most threatening pathogens affecting common carp production as well as the highly valuable ornamental koi carp. To date, no effective commercial vaccine is available for worldwide use. A previous study reported that three intramuscular injections with an ORF25-based DNA vaccine, led to the generation of neutralizing antibodies and conferred significant protection against an intraperitoneal challenge with KHV. In the present study, we set out to optimize an ORF25-based DNA vaccination protocol that required fewer injections and would confer protection upon a challenge that better resembled the natural route of infection. To this end, ORF25 was cloned in pcDNA3 either as a soluble protein or as a full-length transmembrane GFP-fusion protein. We tested our ORF25-based DNA vaccines in multiple vaccination trials using different doses, vaccination routes (i.m. injection and oral gavage) and challenge methods (bath and cohabitation). Furthermore, we analysed local and systemic responses to the i.m. injected DNA vaccine through histological and RT-qPCR analysis. We observed a strong protection when fish received three injections of either of the two DNA vaccines. However, this protection was observed only after bath challenge and not after cohabitation challenge. Furthermore, protection was insufficient when fish received one injection only, or received the plasmid orally. The importance of choosing a challenge model that best reflects the natural route of infection and the possibility to include additional antigens in future DNA vaccination strategies against KHV will be discussed. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  14. Injection molding lens metrology using software configurable optical test system

    NASA Astrophysics Data System (ADS)

    Zhan, Cheng; Cheng, Dewen; Wang, Shanshan; Wang, Yongtian

    2016-10-01

    Optical plastic lens produced by injection molding machine possesses numerous advantages of light quality, impact resistance, low cost, etc. The measuring methods in the optical shop are mainly interferometry, profile meter. However, these instruments are not only expensive, but also difficult to alignment. The software configurable optical test system (SCOTS) is based on the geometry of the fringe refection and phase measuring deflectometry method (PMD), which can be used to measure large diameter mirror, aspheric and freeform surface rapidly, robustly, and accurately. In addition to the conventional phase shifting method, we propose another data collection method called as dots matrix projection. We also use the Zernike polynomials to correct the camera distortion. This polynomials fitting mapping distortion method has not only simple operation, but also high conversion precision. We simulate this test system to measure the concave surface using CODE V and MATLAB. The simulation results show that the dots matrix projection method has high accuracy and SCOTS has important significance for on-line detection in optical shop.

  15. Study of effects of injector geometry on fuel-air mixing and combustion

    NASA Technical Reports Server (NTRS)

    Bangert, L. H.; Roach, R. L.

    1977-01-01

    An implicit finite-difference method has been developed for computing the flow in the near field of a fuel injector as part of a broader study of the effects of fuel injector geometry on fuel-air mixing and combustion. Detailed numerical results have been obtained for cases of laminar and turbulent flow without base injection, corresponding to the supersonic base flow problem. These numerical results indicated that the method is stable and convergent, and that significant savings in computer time can be achieved, compared with explicit methods.

  16. Viscous fingering and channeling in chemical enhanced oil recovery

    NASA Astrophysics Data System (ADS)

    Daripa, Prabir; Dutta, Sourav

    2017-11-01

    We have developed a hybrid numerical method based on discontinuous finite element method and modified method of characteristics to compute the multiphase multicomponent fluid flow in porous media in the context of chemical enhanced oil recovery. We use this method to study the effect of various chemical components on the viscous fingering and channeling in rectilinear and radial flow configurations. We will also discuss about the efficiency of various flooding schemes based on these understandings. Time permitting, we will discuss about the effect of variable injection rates in these practical setting. U.S. National Science Foundation Grant DMS-1522782.

  17. Ictal SPECT using an attachable automated injector: clinical usefulness in the prediction of ictal onset zone.

    PubMed

    Lee, Jung-Ju; Lee, Sang Kun; Choi, Jang Wuk; Kim, Dong-Wook; Park, Kyung Il; Kim, Bom Sahn; Kang, Hyejin; Lee, Dong Soo; Lee, Seo-Young; Kim, Sung Hun; Chung, Chun Kee; Nam, Hyeon Woo; Kim, Kwang Ki

    2009-12-01

    Ictal single-photon emission computed tomography (SPECT) is a valuable method for localizing the ictal onset zone in the presurgical evaluation of patients with intractable epilepsy. Conventional methods used to localize the ictal onset zone have problems with time lag from seizure onset to injection. To evaluate the clinical usefulness of a method that we developed, which involves an attachable automated injector (AAI), in reducing time lag and improving the ability to localize the zone of seizure onset. Patients admitted to the epilepsy monitoring unit (EMU) between January 1, 2003, and June 30, 2008, were included. The definition of ictal onset zone was made by comprehensive review of medical records, magnetic resonance imaging (MRI), data from video electroencephalography (EEG) monitoring, and invasive EEG monitoring if available. We comprehensively evaluated the time lag to injection and the image patterns of ictal SPECT using traditional visual analysis, statistical parametric mapping-assisted, and subtraction ictal SPECT coregistered to an MRI-assisted means of analysis. Image patterns were classified as localizing, lateralizing, and nonlateralizing. The whole number of patients was 99: 48 in the conventional group and 51 in the AAI group. The mean (SD) delay time to injection from seizure onset was 12.4+/-12.0 s in the group injected by our AAI method and 40.4+/-26.3 s in the group injected by the conventional method (P=0.000). The mean delay time to injection from seizure detection was 3.2+/-2.5 s in the group injected by the AAI method and 21.4+/-9.7 s in the group injected by the conventional method (P=0.000). The AAI method was superior to the conventional method in localizing the area of seizure onset (36 out of 51 with AAI method vs. 21 out of 48 with conventional method, P=0.009), especially in non-temporal lobe epilepsy (non-TLE) patients (17 out of 27 with AAI method vs. 3 out of 13 with conventional method, P=0.041), and in lateralizing the seizure onset hemisphere (47 out of 51 with AAI method vs. 33 out of 48 with conventional method, P=0.004). The AAI method was superior to the conventional method in reducing the time lag of tracer injection and in localizing and lateralizing the ictal onset zone, especially in patients with non-TLE.

  18. A randomised controlled comparison of injection, thermal, and mechanical endoscopic methods of haemostasis on mesenteric vessels.

    PubMed

    Hepworth, C C; Kadirkamanathan, S S; Gong, F; Swain, C P

    1998-04-01

    A randomised controlled comparison of haemostatic efficacy of mechanical, injection, and thermal methods of haemostasis was undertaken using canine mesenteric vessels to test the hypothesis that mechanical methods of haemostasis are more effective in controlling haemorrhage than injection or thermal methods. The diameter of arteries in human bleeding ulcers measures up to 3.45 mm; mesenteric vessels up to 5 mm were therefore studied. Mesenteric vessels were randomised to treatment with injection sclerotherapy (adrenaline and ethanolamine), bipolar diathermy, or mechanical methods (band, clips, sewing machine, endoloops). The vessels were severed and haemostasis recorded. Injection sclerotherapy and clips failed to stop bleeding from vessels of 1 mm (n = 20) and 2 mm (n = 20). Bipolar diathermy was effective on 8/10 vessels of 2 mm but failed on 3 mm vessels (n = 5). Unstretched elastic bands succeeded on 13/15 vessels of 2 mm but on only 3/10 vessels of 3 mm. The sewing machine achieved haemostasis on 8/10 vessels of 4 mm but failed on 5 mm vessels (n = 5); endoloops were effective on all 5 mm vessels (n = 5). Only mechanical methods were effective on vessels greater than 2 mm in diameter. Some mechanical methods (banding and clips) were less effective than expected and need modification. Thermal and (effective) mechanical methods were significantly (p < 0.01) more effective than injection sclerotherapy. The most effective mechanical methods were significantly more effective (p < 0.01) than thermal or injection on vessels greater than 2 mm.

  19. Research on the technology of detecting the SQL injection attack and non-intrusive prevention in WEB system

    NASA Astrophysics Data System (ADS)

    Hu, Haibin

    2017-05-01

    Among numerous WEB security issues, SQL injection is the most notable and dangerous. In this study, characteristics and procedures of SQL injection are analyzed, and the method for detecting the SQL injection attack is illustrated. The defense resistance and remedy model of SQL injection attack is established from the perspective of non-intrusive SQL injection attack and defense. Moreover, the ability of resisting the SQL injection attack of the server has been comprehensively improved through the security strategies on operation system, IIS and database, etc.. Corresponding codes are realized. The method is well applied in the actual projects.

  20. Sensorless position estimation and control of permanent-magnet synchronous motors using a saturation model

    NASA Astrophysics Data System (ADS)

    Kassem Jebai, Al; Malrait, François; Martin, Philippe; Rouchon, Pierre

    2016-03-01

    Sensorless control of permanent-magnet synchronous motors at low velocity remains a challenging task. A now well-established method consists of injecting a high-frequency signal and using the rotor saliency, both geometric and magnetic-saturation induced. This paper proposes a clear and original analysis based on second-order averaging of how to recover the position information from signal injection; this analysis blends well with a general model of magnetic saturation. It also proposes a simple parametric model of the saturated motor, based on an energy function which simply encompasses saturation and cross-saturation effects. Experimental results on a surface-mounted motor and an interior magnet motor illustrate the relevance of the approach.

  1. Convergence and objective functions of some fault/noise-injection-based online learning algorithms for RBF networks.

    PubMed

    Ho, Kevin I-J; Leung, Chi-Sing; Sum, John

    2010-06-01

    In the last two decades, many online fault/noise injection algorithms have been developed to attain a fault tolerant neural network. However, not much theoretical works related to their convergence and objective functions have been reported. This paper studies six common fault/noise-injection-based online learning algorithms for radial basis function (RBF) networks, namely 1) injecting additive input noise, 2) injecting additive/multiplicative weight noise, 3) injecting multiplicative node noise, 4) injecting multiweight fault (random disconnection of weights), 5) injecting multinode fault during training, and 6) weight decay with injecting multinode fault. Based on the Gladyshev theorem, we show that the convergence of these six online algorithms is almost sure. Moreover, their true objective functions being minimized are derived. For injecting additive input noise during training, the objective function is identical to that of the Tikhonov regularizer approach. For injecting additive/multiplicative weight noise during training, the objective function is the simple mean square training error. Thus, injecting additive/multiplicative weight noise during training cannot improve the fault tolerance of an RBF network. Similar to injective additive input noise, the objective functions of other fault/noise-injection-based online algorithms contain a mean square error term and a specialized regularization term.

  2. Sensitive determination of 2-methoxyestradiol in pharmaceutical preparations and serum samples using flow injection chemiluminescence.

    PubMed

    Yao, Hanchun; Zhang, Min; Zeng, Wenyuan; Zeng, Xiaoying; Zhang, Zhenzhong

    2014-05-01

    A rapid and sensitive flow injection chemiluminescence (FI-CL) method is described for the determination of 2-methoxyestradiol (2ME) based on enhancement of the CL intensity from a potassium ferricyanide-calcein system in sodium hydroxide medium. The optimum conditions for the CL emission were investigated. Under optimized conditions, a linear calibration graph was obtained over the range 1.0 × 10(-8) to 1.0 × 10(-6) mol/L (r = 0.998) 2ME with a detection limit (3σ) of 5.4 × 10(-9) mol/L. The relative standard deviation (RSD) for 5.0 × 10(-7) mol/L 2ME was 1.7%. As a preliminary application, the proposed method was successfully applied to the determination of 2ME in injection solutions and serum samples. The possible CL mechanism was also proposed. Copyright © 2013 John Wiley & Sons, Ltd.

  3. Sensitive flow-injection spectrophotometric analysis of bromopride

    NASA Astrophysics Data System (ADS)

    Lima, Liliane Spazzapam; Weinert, Patrícia Los; Pezza, Leonardo; Pezza, Helena Redigolo

    2014-12-01

    A flow injection spectrophotometric procedure employing merging zones is proposed for direct bromopride determination in pharmaceutical formulations and biological fluids. The proposed method is based on the reaction between bromopride and p-dimethylaminocinnamaldehyde (p-DAC) in acid medium, in the presence of sodium dodecyl sulfate (SDS), resulting in formation of a violet product (λmax = 565 nm). Experimental design methodologies were used to optimize the experimental conditions. The Beer-Lambert law was obeyed in a bromopride concentration range of 3.63 × 10-7 to 2.90 × 10-5 mol L-1, with a correlation coefficient (r) of 0.9999. The limits of detection and quantification were 1.07 × 10-7 and 3.57 × 10-7 mol L-1, respectively. The proposed method was successfully applied to the determination of bromopride in pharmaceuticals and human urine, and recoveries of the drug from these media were in the ranges 99.6-101.2% and 98.6-102.1%, respectively. This new flow injection procedure does not require any sample pretreatment steps.

  4. Maximize Liquid Oil Production from Shale Oil and Gas Condensate Reservoirs by Cyclic Gas Injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, James; Li, Lei; Yu, Yang

    The current technology to produce shale oil reservoirs is the primary depletion using fractured wells (generally horizontal wells). The oil recovery is less than 10%. The prize to enhance oil recovery (EOR) is big. Based on our earlier simulation study, huff-n-puff gas injection has the highest EOR potential. This project was to explore the potential extensively and from broader aspects. The huff-n-puff gas injection was compared with gas flooding, water huff-n-puff and waterflooding. The potential to mitigate liquid blockage was also studied and the gas huff-n-puff method was compared with other solvent methods. Field pilot tests were initiated but terminatedmore » owing to the low oil price and the operator’s budget cut. To meet the original project objectives, efforts were made to review existing and relevant field projects in shale and tight reservoirs. The fundamental flow in nanopores was also studied.« less

  5. Ionic liquid and aqueous two-phase extraction based on salting-out coupled with high-performance liquid chromatography for the determination of seven rare ginsenosides in Xue-Sai-Tong injection.

    PubMed

    Li, Lan-Jie; Jin, Yong-Ri; Wang, Xiao-Zhong; Liu, Ying; Wu, Qian; Shi, Xiao-Lei; Li, Xu-Wen

    2015-09-01

    A method of ionic liquid salt aqueous two-phase extraction coupled with high-performance liquid chromatography has been developed for the analysis of seven rare ginsenosides including Rg6 , F4 , 20(S)-Rg3 , 20(R)-Rg3 , Rk3 , Rk1 , and Rg5 in Xue-Sai-Tong injection. The injection was mixed with ionic liquid 1-butyl-3-methylimidazolium bromide aqueous solution, and a mixture was obtained. With the addition of sodium dodecyl sulfate and dipotassium phosphate into the mixture, the aqueous two-phase mixture was formed after ultrasonic treatment and centrifuged. Rare ginsenosides were extracted into the upper phase. To obtain a high extraction factors, various influences were considered systematically, such as the volume of ionic liquid, the category and amount of salts, the amount of sodium dodecyl sulfate, the pH value of system, and the time of ultrasonic treatment. Under the optimal condition, rare ginsenosides in Xue-Sai-Tong injection were enriched and detected, the recoveries of seven rare ginsenosides ranged from 90.05 to 112.55%, while relative standard deviations were lower than 2.50%. The developed method was reliable, rapid and sensitive for the determination of seven rare ginsenosides in the injections. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Light extinction method on high-pressure diesel injection

    NASA Astrophysics Data System (ADS)

    Su, Tzay-Fa; El-Beshbeeshy, Mahmound S.; Corradini, Michael L.; Farrell, Patrick V.

    1995-09-01

    A two dimensional optical diagnostic technique based on light extinction was improved and demonstrated in an investigation of diesel spray characteristics at high injection pressures. Traditional light extinction methods require the spray image to be perpendicular to the light path. In the improved light extinction scheme, a tilted spray image which has an angle with the light path is still capable of being processed. This technique utilizes high speed photography and digital image analysis to obtain qualitative and quantitative information of the spray characteristics. The injection system used was an electronically controlled common rail unit injector system with injection pressures up to 100 MPa. The nozzle of the injector was a mini-sac type with six holes on the nozzle tip. Two different injection angle nozzles, 125 degree(s) and 140 degree(s), producing an in-plane tilted spray and an out of plane tilted spray were investigated. The experiments were conducted on a constant volume spray chamber with the injector mounted tilted at an angle of 62.5 degree(s)$. Only one spray plume was viewed, and other sprays were free to inject to the chamber. The spray chamber was pressurized with argon and air under room temperature to match the combustion chamber density at the start of the injection. The experimental results show that the difference in the spray tip penetration length, spray angle, and overall average Sauter mean diameter is small between the in- plane tilted spray and the out of plane tilted spray. The results also show that in-plane tilted spray has a slightly larger axial cross- section Sauter mean diameter than the out of plane tilted spray.

  7. The numerical modelling of mixing phenomena of nanofluids in passive micromixers

    NASA Astrophysics Data System (ADS)

    Milotin, R.; Lelea, D.

    2018-01-01

    The paper deals with the rapid mixing phenomena in micro-mixing devices with four tangential injections and converging tube, considering nanoparticles and water as the base fluid. Several parameters like Reynolds number (Re = 6 - 284) or fluid temperature are considered in order to optimize the process and obtain fundamental insight in mixing phenomena. The set of partial differential equations is considered based on conservation of momentum and species. Commercial package software Ansys-Fluent is used for solution of differential equations, based on a finite volume method. The results reveal that mixing index and mixing process is strongly dependent both on Reynolds number and heat flux. Moreover there is a certain Reynolds number when flow instabilities are generated that intensify the mixing process due to the tangential injections of the fluids.

  8. Fast cholesterol detection using flow injection microfluidic device with functionalized carbon nanotubes based electrochemical sensor.

    PubMed

    Wisitsoraat, A; Sritongkham, P; Karuwan, C; Phokharatkul, D; Maturos, T; Tuantranont, A

    2010-12-15

    This work reports a new cholesterol detection scheme using functionalized carbon nanotube (CNT) electrode in a polydimethylsiloxane/glass based flow injection microfluidic chip. CNTs working, silver reference and platinum counter electrode layers were fabricated on the chip by sputtering and low temperature chemical vapor deposition methods. Cholesterol oxidase prepared in polyvinyl alcohol solution was immobilized on CNTs by in-channel flow technique. Cholesterol analysis based on flow injection chronoamperometric measurement was performed in 150-μm-wide and 150-μm-deep microchannels. Fast and sensitive real-time detection was achieved with high throughput of more than 60 samples per hour and small sample volume of 15 μl. The cholesterol sensor had a linear detection range between 50 and 400 mg/dl. In addition, low cross-sensitivities toward glucose, ascorbic acid, acetaminophen and uric acid were confirmed. The proposed system is promising for clinical diagnostics of cholesterol with high speed real-time detection capability, very low sample consumption, high sensitivity, low interference and good stability. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Improved hydrostatic pressure sample injection by tilting the microchip towards the disposable miniaturized CE device.

    PubMed

    Wang, Wei; Zhou, Fang; Zhao, Liang; Zhang, Jian-Rong; Zhu, Jun-Jie

    2008-02-01

    A simple method of hydrostatic pressure sample injection towards a disposable microchip CE device was developed. The liquid level in the sample reservoir was higher than that in the sample waste reservoir (SWR) by tilting microchip and hydrostatic pressure was generated, the sample was driven to pass through injection channel into SWR. After sample loading, the microchip was levelled for separation under applied high separation voltage. Effects of tilted angle, initial liquid height and injection duration on electrophoresis were investigated. With enough injection duration, the injection result was little affected by tilted angle and initial liquid heights in the reservoirs. Injection duration for obtaining a stable sample plug was mainly dependent on the tilted angle rather than the initial height of liquid. Experimental results were consistent with theoretical prediction. Fluorescence observation and electrochemical detection of dopamine and catechol were employed to verify the feasibility of tilted microchip hydrostatic pressure injection. Good reproducibility of this injection method was obtained. Because the instrumentation was simplified and no additional hardware was needed in this technology, the proposed method would be potentially useful in disposable devices.

  10. Web-based interactive 3D visualization as a tool for improved anatomy learning.

    PubMed

    Petersson, Helge; Sinkvist, David; Wang, Chunliang; Smedby, Orjan

    2009-01-01

    Despite a long tradition, conventional anatomy education based on dissection is declining. This study tested a new virtual reality (VR) technique for anatomy learning based on virtual contrast injection. The aim was to assess whether students value this new three-dimensional (3D) visualization method as a learning tool and what value they gain from its use in reaching their anatomical learning objectives. Several 3D vascular VR models were created using an interactive segmentation tool based on the "virtual contrast injection" method. This method allows users, with relative ease, to convert computer tomography or magnetic resonance images into vivid 3D VR movies using the OsiriX software equipped with the CMIV CTA plug-in. Once created using the segmentation tool, the image series were exported in Quick Time Virtual Reality (QTVR) format and integrated within a web framework of the Educational Virtual Anatomy (EVA) program. A total of nine QTVR movies were produced encompassing most of the major arteries of the body. These movies were supplemented with associated information, color keys, and notes. The results indicate that, in general, students' attitudes towards the EVA-program were positive when compared with anatomy textbooks, but results were not the same with dissections. Additionally, knowledge tests suggest a potentially beneficial effect on learning.

  11. [Construction of NIRS-based process analytical system for production of salvianolic acid for injection and relative discussion].

    PubMed

    Zhang, Lei; Yue, Hong-Shui; Ju, Ai-Chun; Ye, Zheng-Liang

    2016-10-01

    Currently, near infrared spectroscopy (NIRS) has been considered as an efficient tool for achieving process analytical technology(PAT) in the manufacture of traditional Chinese medicine (TCM) products. In this article, the NIRS based process analytical system for the production of salvianolic acid for injection was introduced. The design of the process analytical system was described in detail, including the selection of monitored processes and testing mode, and potential risks that should be avoided. Moreover, the development of relative technologies was also presented, which contained the establishment of the monitoring methods for the elution of polyamide resin and macroporous resin chromatography processes, as well as the rapid analysis method for finished products. Based on author's experience of research and work, several issues in the application of NIRS to the process monitoring and control in TCM production were then raised, and some potential solutions were also discussed. The issues include building the technical team for process analytical system, the design of the process analytical system in the manufacture of TCM products, standardization of the NIRS-based analytical methods, and improving the management of process analytical system. Finally, the prospect for the application of NIRS in the TCM industry was put forward. Copyright© by the Chinese Pharmaceutical Association.

  12. Kinetic modeling of PET-FDG in the brain without blood sampling.

    PubMed

    Bentourkia, M'hamed

    2006-12-01

    The aim in this work is to report a new method to calculate parametric images from a single scan acquisition with positron emission tomography (PET) and fluorodeoxyglucose (FDG) in the human brain without blood sampling. It is usually practical for research or clinical purposes to inject the patient in an isolated room and to start the PET acquisition only for some 10-20 min, about 30 min after FDG injection. In order to calculate the cerebral metabolic rates for glucose (CMRG), usually several blood samples are required. The proposed method considers the relation between the uptake of the tracer in the cerebellum as a reference tissue and the population based input curve. Similar results were obtained for CMRG values with the present method in comparison to the usual autoradiographic and the non-linear least squares fitting of regions of interest.

  13. Evaluation of injection augmentation treatment of hyaluronic acid based materials on rabbit vocal folds viscoelasticity.

    PubMed

    Borzacchiello, A; Mayol, L; Gärskog, O; Dahlqvist, A; Ambrosio, L

    2005-06-01

    The viscoelastic properties of vocal folds after injection of hyaluronic acid (hyaluronan, HA) based materials have been studied in an animal model (rabbit) six months after injection. The results indicate that the viscoelastic properties of the vocal folds injected with the HA based materials are similar to the healthy vocal folds (non-injected samples) used as control. Histological analysis has been also performed to investigate on the fate of the injected materials after six months from the implant. The HA based materials remain up to six months and they recruited fibroblasts that induce the ingrowth of new connective tissue resulting in an endogenous soft tissue augmentation. The HA based compounds are good candidate for further studies aimed at restoring/preserving the vibratory capacity of the vocal folds with injection treatment in glottal insufficiency.

  14. A radiopaque polymer hydrogel used as a fiducial marker in gynecologic-cancer patients receiving brachytherapy

    PubMed Central

    Bair, Ryan J.; Bair, Eric; Viswanathan, Akila N.

    2016-01-01

    PURPOSE We assessed a novel Food and Drug Administration–approved hydrogel, synthesized as absorbable iodinated particles, in gynecologic-cancer patients undergoing computed tomography (CT) or magnetic resonance (MR) based brachytherapy after external beam radiation. METHODS AND MATERIALS Nineteen patients underwent CT-guided (n = 13) or MR-guided (n = 6) brachytherapy for gynecologic cancers. Seventy-seven hydrogel injections were placed. The hydrogel material was injected into gross residual disease and/or key anatomic landmarks in amounts ranging from 0.1 to 0.4 mL. The visibility of the tracer was scored on CT and on MR images using a 5-point scoring scale. A Cohen’s kappa statistic was calculated to assess interobserver agreement. To assess the unadjusted effects of baseline parameters on hydrogel visibility, we modeled visibility using a linear mixed-effect model. RESULTS Injections were without complication. The kappa statistic was 0.77 (95% confidence interval [CI], 0.68–0.87). The volume of hydrogel injected was significantly associated with visibility on both CT (p = 0.032) and magnetic resonance imaging (p = 0.016). We analyzed visibility by location, controlling for amount. A 0.1-cc increase in volume injected was associated with increases of 0.54 (95% CI = 0.05–1.03) in the CT visibility score and 0.83 (95% CI = 0.17–1.49) in the MR visibility score. Injection of 0.4 cc or more was required for unequivocal visibility on CT or MR. No statistically significant correlation was found between tumor type, tumor location, or anatomical location of injection and visibility on either CT or magnetic resonance imaging. CONCLUSIONS In this first report of an injectable radiopaque hydrogel, targets were visualized to assist with three-dimensional–based brachytherapy in gynecologic malignancies. This marker has potential for several applications, is easy to inject and visualize, and caused no acute complications. PMID:26481393

  15. Numerical Simulation of Sintering Process in Ceramic Powder Injection Moulded Components

    NASA Astrophysics Data System (ADS)

    Song, J.; Barriere, T.; Liu, B.; Gelin, J. C.

    2007-05-01

    A phenomenological model based on viscoplastic constitutive law is presented to describe the sintering process of ceramic components obtained by powder injection moulding. The parameters entering in the model are identified through sintering experiments in dilatometer with the proposed optimization method. The finite element simulations are carried out to predict the density variations and dimensional changes of the components during sintering. A simulation example on the sintering process of hip implant in alumina has been conducted. The simulation results have been compared with the experimental ones. A good agreement is obtained.

  16. Sequential injection gas guns for accelerating projectiles

    DOEpatents

    Lacy, Jeffrey M [Idaho Falls, ID; Chu, Henry S [Idaho Falls, ID; Novascone, Stephen R [Idaho Falls, ID

    2011-11-15

    Gas guns and methods for accelerating projectiles through such gas guns are described. More particularly, gas guns having a first injection port located proximate a breech end of a barrel and a second injection port located longitudinally between the first injection port and a muzzle end of the barrel are described. Additionally, modular gas guns that include a plurality of modules are described, wherein each module may include a barrel segment having one or more longitudinally spaced injection ports. Also, methods of accelerating a projectile through a gas gun, such as injecting a first pressurized gas into a barrel through a first injection port to accelerate the projectile and propel the projectile down the barrel past a second injection port and injecting a second pressurized gas into the barrel through the second injection port after passage of the projectile and to further accelerate the projectile are described.

  17. Compliance and use behaviour, an issue in injectable as well as oral contraceptive use? A study of injectable and oral contraceptive use in Johannesburg.

    PubMed

    Beksinska, M E; Rees, V H; Nkonyane, T; McIntyre, J A

    1998-04-01

    This study examines the compliance, use behaviour and knowledge of method of women using injectable and oral contraceptives in two clinic sites in the Johannesburg area, South Africa. An interviewer administered questionnaire was used to collect information in the clients' home language. A total of 400 women were interviewed in the clinics. The mean age of clients was 26.2 years (range 13 to 43 years). Of the clients not wanting to get pregnant, 30.4 per cent of injectable users and 18.4 per cent of oral contraceptive (OC) users had stopped using their method temporarily before returning to the same method (called the nonuse segment) and had not used any other form of contraception during this time. Almost one third of injectable users (31.2 per cent) had been late for their next injection at least once. Although nearly all women using injectables had experienced some menstrual disturbances, over one third (38.5 per cent) had not been informed by the providers about the possibility of these changes. Many women gave the disruption of their menstrual cycle as the reason for the nonuse segment. The majority of OC users lacked information on how to use their method correctly. Nearly all women expressed an interest in obtaining more information on their current method and other available methods. This study shows that compliance is an issue in injectable as well as OC users.

  18. Drug delivery into the cochlear apex: Improved control to sequentially affect finely spaced regions along the entire length of the cochlear spiral

    PubMed Central

    Lichtenhan, JT; Hartsock, J; Dornhoffer, JR; Donovan, KM; Salt, AN

    2016-01-01

    Background Administering pharmaceuticals to the scala tympani of the inner ear is a common approach to study cochlear physiology and mechanics. We present here a novel method for in vivo drug delivery in a controlled manner to sealed ears. New method Injections of ototoxic solutions were applied from a pipette sealed into a fenestra in the cochlear apex, progressively driving solutions along the length of scala tympani toward the cochlear aqueduct at the base. Drugs can be delivered rapidly or slowly. In this report we focus on slow delivery in which the injection rate is automatically adjusted to account for varying cross sectional area of the scala tympani, therefore driving a solution front at uniform rate. Results Objective measurements originating from finely spaced, low- to high-characteristic cochlear frequency places were sequentially affected. Comparison with existing methods(s): Controlled administration of pharmaceuticals into the cochlear apex overcomes a number of serious limitations of previously established methods such as cochlear perfusions with an injection pipette in the cochlear base: The drug concentration achieved is more precisely controlled, drug concentrations remain in scala tympani and are not rapidly washed out by cerebrospinal fluid flow, and the entire length of the cochlear spiral can be treated quickly or slowly with time. Conclusions Controlled administration of solutions into the cochlear apex can be a powerful approach to sequentially effect objective measurements originating from finely spaced cochlear regions and allows, for the first time, the spatial origin of CAPs to be objectively defined. PMID:27506463

  19. Influence of injection mode on transport properties in kilometer-scale three-dimensional discrete fracture networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hyman, Jeffrey De'Haven; Painter, S. L.; Viswanathan, H.

    We investigate how the choice of injection mode impacts transport properties in kilometer-scale three-dimensional discrete fracture networks (DFN). The choice of injection mode, resident and flux-weighted, is designed to mimic different physical phenomena. It has been hypothesized that solute plumes injected under resident conditions evolve to behave similarly to solutes injected under flux-weighted conditions. Previously, computational limitations have prohibited the large-scale simulations required to investigate this hypothesis. We investigate this hypothesis by using a high-performance DFN suite, dfnWorks, to simulate flow in kilometer-scale three-dimensional DFNs based on fractured granite at the Forsmark site in Sweden, and adopt a Lagrangian approachmore » to simulate transport therein. Results show that after traveling through a pre-equilibrium region, both injection methods exhibit linear scaling of the first moment of travel time and power law scaling of the breakthrough curve with similar exponents, slightly larger than 2. Lastly, the physical mechanisms behind this evolution appear to be the combination of in-network channeling of mass into larger fractures, which offer reduced resistance to flow, and in-fracture channeling, which results from the topology of the DFN.« less

  20. Influence of injection mode on transport properties in kilometer-scale three-dimensional discrete fracture networks

    DOE PAGES

    Hyman, Jeffrey De'Haven; Painter, S. L.; Viswanathan, H.; ...

    2015-09-12

    We investigate how the choice of injection mode impacts transport properties in kilometer-scale three-dimensional discrete fracture networks (DFN). The choice of injection mode, resident and flux-weighted, is designed to mimic different physical phenomena. It has been hypothesized that solute plumes injected under resident conditions evolve to behave similarly to solutes injected under flux-weighted conditions. Previously, computational limitations have prohibited the large-scale simulations required to investigate this hypothesis. We investigate this hypothesis by using a high-performance DFN suite, dfnWorks, to simulate flow in kilometer-scale three-dimensional DFNs based on fractured granite at the Forsmark site in Sweden, and adopt a Lagrangian approachmore » to simulate transport therein. Results show that after traveling through a pre-equilibrium region, both injection methods exhibit linear scaling of the first moment of travel time and power law scaling of the breakthrough curve with similar exponents, slightly larger than 2. Lastly, the physical mechanisms behind this evolution appear to be the combination of in-network channeling of mass into larger fractures, which offer reduced resistance to flow, and in-fracture channeling, which results from the topology of the DFN.« less

  1. New kind of injection-locked oscillator and its corresponding long-term stability control.

    PubMed

    Hong, Jun; Liu, An; Wang, Xiao-hu; Yao, Sheng-xing; Li, Zu-ling

    2015-09-20

    A new type of opto-electronic hybrid oscillator is proposed for the first time, to the best of our knowledge, and verified by experiments in this paper. Typical electronic oscillator-dielectric resonator oscillator as the first injection source is used to injection lock the first long-fiber loop-based opto-electronic oscillator (OEO); then its output is used to injection lock the second long-fiber opto-electronic oscillator. Using this method, low-phase noise output signal can be obtained. Experiments show that single side-band (SSB) phase noise of a 9.5 GHz oscillation signal at 10 kHz offset frequency decreases from -123 to -135  dBc/Hz after the first injection, then, through the second injection, the SSB phase noise drops down to -146  dBc/Hz. In order to solve the long-term stability problem of the above oscillator, a new stability-control circuit also is designed and verified by experiments. Experiments show that the Allan deviation decreases from 9.0×10(-11) to 2.2×10(-12) during 1 s after the long-term stability-control circuit being used.

  2. A risk-based multi-objective model for optimal placement of sensors in water distribution system

    NASA Astrophysics Data System (ADS)

    Naserizade, Sareh S.; Nikoo, Mohammad Reza; Montaseri, Hossein

    2018-02-01

    In this study, a new stochastic model based on Conditional Value at Risk (CVaR) and multi-objective optimization methods is developed for optimal placement of sensors in water distribution system (WDS). This model determines minimization of risk which is caused by simultaneous multi-point contamination injection in WDS using CVaR approach. The CVaR considers uncertainties of contamination injection in the form of probability distribution function and calculates low-probability extreme events. In this approach, extreme losses occur at tail of the losses distribution function. Four-objective optimization model based on NSGA-II algorithm is developed to minimize losses of contamination injection (through CVaR of affected population and detection time) and also minimize the two other main criteria of optimal placement of sensors including probability of undetected events and cost. Finally, to determine the best solution, Preference Ranking Organization METHod for Enrichment Evaluation (PROMETHEE), as a subgroup of Multi Criteria Decision Making (MCDM) approach, is utilized to rank the alternatives on the trade-off curve among objective functions. Also, sensitivity analysis is done to investigate the importance of each criterion on PROMETHEE results considering three relative weighting scenarios. The effectiveness of the proposed methodology is examined through applying it to Lamerd WDS in the southwestern part of Iran. The PROMETHEE suggests 6 sensors with suitable distribution that approximately cover all regions of WDS. Optimal values related to CVaR of affected population and detection time as well as probability of undetected events for the best optimal solution are equal to 17,055 persons, 31 mins and 0.045%, respectively. The obtained results of the proposed methodology in Lamerd WDS show applicability of CVaR-based multi-objective simulation-optimization model for incorporating the main uncertainties of contamination injection in order to evaluate extreme value of losses in WDS.

  3. Use of Fc-Engineered Antibodies as Clearing Agents to Increase Contrast During PET

    PubMed Central

    Swiercz, Rafal; Chiguru, Srinivas; Tahmasbi, Amir; Ramezani, Saleh M.; Hao, Guiyang; Challa, Dilip K.; Lewis, Matthew A.; Kulkarni, Padmakar V.; Sun, Xiankai; Ober, Raimund J.; Mason, Ralph P.; Ward, E. Sally

    2015-01-01

    Despite promise for the use of antibodies as molecular imaging agents in PET, their long in vivo half-lives result in poor contrast and radiation damage to normal tissue. This study describes an approach to overcome these limitations. Methods Mice bearing human epidermal growth factor receptor type 2 (HER2)–overexpressing tumors were injected with radiolabeled (124I, 125I) HER2-specific antibody (pertuzumab). Pertuzumab injection was followed 8 h later by the delivery of an engineered, antibody-based inhibitor of the receptor, FcRn. Biodistribution analyses and PET were performed at 24 and 48 h after pertuzumab injection. Results The delivery of the engineered, antibody-based FcRn inhibitor (or Abdeg, for antibody that enhances IgG degradation) results in improved tumor-to-blood ratios, reduced systemic exposure to radiolabel, and increased contrast during PET. Conclusion Abdegs have considerable potential as agents to stringently regulate antibody dynamics in vivo, resulting in increased contrast during molecular imaging with PET. PMID:24868106

  4. Slow-Injection Growth of Seeded CdSe/CdS Nanorods with Unity Fluorescence Quantum Yield and Complete Shell to Core Energy Transfer.

    PubMed

    Coropceanu, Igor; Rossinelli, Aurelio; Caram, Justin R; Freyria, Francesca S; Bawendi, Moungi G

    2016-03-22

    A two-step process has been developed for growing the shell of CdSe/CdS core/shell nanorods. The method combines an established fast-injection-based step to create the initial elongated shell with a second slow-injection growth that allows for a systematic variation of the shell thickness while maintaining a high degree of monodispersity at the batch level and enhancing the uniformity at the single-nanorod level. The second growth step resulted in nanorods exhibiting a fluorescence quantum yield up to 100% as well as effectively complete energy transfer from the shell to the core. This improvement suggests that the second step is associated with a strong suppression of the nonradiative channels operating both before and after the thermalization of the exciton. This hypothesis is supported by the suppression of a defect band, ubiquitous to CdSe-based nanocrystals after the second growth.

  5. Injection laryngoplasty as miniinvasive office-based surgery in patients with unilateral vocal fold paralysis - voice quality outcomes.

    PubMed

    Sielska-Badurek, Ewelina M; Sobol, Maria; Jędra, Katarzyna; Rzepakowska, Anna; Osuch-Wójcikiewicz, Ewa; Niemczyk, Kazimierz

    2017-09-01

    Injection laryngoplasty (glottis augmentation) is the preferred method in surgical management of unilateral vocal fold paralysis (UVFP). Traditionally, these procedures are performed in the operating room. Nowadays, however, these procedures have moved into the office. To evaluate the voice quality after transoral injection laryngoplasty under local anaesthesia in patients with unilateral vocal fold paralysis. Fourteen subjects (5 women and 9 men) with unilateral vocal fold paresis (9 with right vocal fold paresis and 5 with left vocal fold paresis) were included in the study. The mean age of the group was 57.8 ±19.0 years (32-83 years). All of the injection laryngoplasties were performed transorally, under local anaesthesia. The injection material was calcium hydroxylapatite. Before and 1, 3 and 6 months after the procedure the following variables were evaluated: voice perception, videostroboscopy, acoustic analysis, aerodynamic evaluation, and the subjective rating of the voice quality by the patient. After injection laryngoplasty, complete glottal closure was achieved or there was a significant improvement in the glottal closure of each subject. We noted great improvement in the post-injection objective and subjective voice outcomes and patients reported improvement in the voice-related quality of life. The transoral approach for injection laryngoplasty under local anaesthesia is an effective and safe way to treat incomplete glottal closure in patients with UVFP. The transoral approach is an efficient alternative to other surgical techniques used for vocal fold injection.

  6. THE REAL ESTATE OF MYOBLAST CARDIAC TRANSPLANTATION – NEGATIVE REMODELING IS ASSOCIATED WITH LOCATION

    PubMed Central

    McCue, Jonathan D.; Swingen, Cory; Feldberg, Tanya; Caron, Gabe; Kolb, Adam; Denucci, Christopher; Prabhu, Somnath; Motilall, Randy; Breviu, Brian; Taylor, Doris A.

    2009-01-01

    Background Skeletal myoblast (SKMB) transplantation has been proposed as a therapy for ischemic cardiomyopathy due to its possible role in myogenesis. The relative safety and efficacy based on location within scar is not known. We hypothesized that SKMB transplanted into peripheral scar (compared to central scar) would more effectively attenuate negative left ventricular (LV) remodeling but at the risk of arrhythmia. Methods 34 New Zealand White rabbits underwent mid-left anterior descending artery (LAD) ligation to produce a transmural LV infarction. One month after LAD ligation SKMBs were injected either in the scar center (n=13) or scar periphery (n=10) and compared to saline injection (n=11). Holter monitoring and MRI was performed pre-injection; Holter monitoring was continued until two weeks post injection, with follow-up MRI at one month. Results Centrally-treated animals demonstrated increased LV end systolic volume, end diastolic volume and mass that correlated with injected cell number. There was a trend toward attenuation of negative LV remodeling in peripherally-treated animals compared to vehicle. Significant late ectopy was seen in several centrally-injected animals with no late ectopy seen in peripherally-injected animals. Conclusions We noted untoward effects with respect to negative LV remodeling following central injection, suggesting that transplanted cell location with respect to scar may be a key factor in the safety and efficacy of SKMB cardiac transplantation. Administration of SKMBs into peripheral scar appears safe with a trend toward improved function in comparison to sham injection. PMID:18187097

  7. Optimization of Injection Molding Parameters for HDPE/TiO2 Nanocomposites Fabrication with Multiple Performance Characteristics Using the Taguchi Method and Grey Relational Analysis

    PubMed Central

    Pervez, Hifsa; Mozumder, Mohammad S.; Mourad, Abdel-Hamid I.

    2016-01-01

    The current study presents an investigation on the optimization of injection molding parameters of HDPE/TiO2 nanocomposites using grey relational analysis with the Taguchi method. Four control factors, including filler concentration (i.e., TiO2), barrel temperature, residence time and holding time, were chosen at three different levels of each. Mechanical properties, such as yield strength, Young’s modulus and elongation, were selected as the performance targets. Nine experimental runs were carried out based on the Taguchi L9 orthogonal array, and the data were processed according to the grey relational steps. The optimal process parameters were found based on the average responses of the grey relational grades, and the ideal operating conditions were found to be a filler concentration of 5 wt % TiO2, a barrel temperature of 225 °C, a residence time of 30 min and a holding time of 20 s. Moreover, analysis of variance (ANOVA) has also been applied to identify the most significant factor, and the percentage of TiO2 nanoparticles was found to have the most significant effect on the properties of the HDPE/TiO2 nanocomposites fabricated through the injection molding process. PMID:28773830

  8. Travel-time-based thermal tracer tomography

    NASA Astrophysics Data System (ADS)

    Somogyvári, Márk; Bayer, Peter; Brauchler, Ralf

    2016-05-01

    Active thermal tracer testing is a technique to get information about the flow and transport properties of an aquifer. In this paper we propose an innovative methodology using active thermal tracers in a tomographic setup to reconstruct cross-well hydraulic conductivity profiles. This is facilitated by assuming that the propagation of the injected thermal tracer is mainly controlled by advection. To reduce the effects of density and viscosity changes and thermal diffusion, early-time diagnostics are used and specific travel times of the tracer breakthrough curves are extracted. These travel times are inverted with an eikonal solver using the staggered grid method to reduce constraints from the pre-defined grid geometry and to improve the resolution. Finally, non-reliable pixels are removed from the derived hydraulic conductivity tomograms. The method is applied to successfully reconstruct cross-well profiles as well as a 3-D block of a high-resolution fluvio-aeolian aquifer analog data set. Sensitivity analysis reveals a negligible role of the injection temperature, but more attention has to be drawn to other technical parameters such as the injection rate. This is investigated in more detail through model-based testing using diverse hydraulic and thermal conditions in order to delineate the feasible range of applications for the new tomographic approach.

  9. Multiple injection mode with or without repeated sample injections: Strategies to enhance productivity in countercurrent chromatography.

    PubMed

    Müller, Marco; Wasmer, Katharina; Vetter, Walter

    2018-06-29

    Countercurrent chromatography (CCC) is an all liquid based separation technique typically used for the isolation and purification of natural compounds. The simplicity of the method makes it easy to scale up CCC separations from analytical to preparative and even industrial scale. However, scale-up of CCC separations requires two different instruments with varying coil dimensions. Here we developed two variants of the CCC multiple injection mode as an alternative to increase the throughput and enhance productivity of a CCC separation when using only one instrument. The concept is based on the parallel injection of samples at different points in the CCC column system and the simultaneous separation using one pump only. The wiring of the CCC setup was modified by the insertion of a 6-port selection valve, multiple T-pieces and sample loops. Furthermore, the introduction of storage sample loops enabled the CCC system to be used with repeated injection cycles. Setup and advantages of both multiple injection modes were shown by the isolation of the furan fatty acid 11-(3,4-dimethyl-5-pentylfuran-2-yl)-undecanoic acid (11D5-EE) from an ethyl ester oil rich in 4,7,10,13,16,19-docosahexaenoic acid (DHA-EE). 11D5-EE was enriched in one step from 1.9% to 99% purity. The solvent consumption per isolated amount of analyte could be reduced by ∼40% compared to increased throughput CCC and by ∼5% in the repeated multiple injection mode which also facilitated the isolation of the major compound (DHA-EE) in the sample. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Reduced injection pressures using a compressed air injection technique (CAIT): an in vitro study.

    PubMed

    Tsui, Ban C H; Knezevich, Mark P; Pillay, Jennifer J

    2008-01-01

    High injection pressures have been associated with intraneural injection and persistent neurological injury in animals. Our objective was to test whether a reported simple compressed air injection technique (CAIT) would limit the generation of injection pressures to below a suggested 1,034 mm Hg limit in an in vitro model. After ethics board approval, 30 consenting anesthesiologists injected saline into a semiclosed system. Injection pressures using 30 mL syringes connected to a 22 gauge needle and containing 20 mL of saline were measured for 60 seconds using: (1) a typical "syringe feel" method, and (2) CAIT, thereby drawing 10 mL of air above the saline and compressing this to 5 mL prior to and during injections. All anesthesiologists performed the syringe feel method before introduction and demonstration of CAIT. Using CAIT, no anesthesiologist generated pressures above 1,034 mm Hg, while 29 of 30 produced pressures above this limit at some time using the syringe feel method. The mean pressure using CAIT was lower (636 +/- 71 vs. 1378 +/- 194 mm Hg, P = .025), and the syringe feel method resulted in higher peak pressures (1,875 +/- 206 vs. 715 +/- 104 mm Hg, P = .000). This study demonstrated that CAIT can effectively keep injection pressures under 1,034 mm Hg in this in vitro model. Animal and clinical studies will be needed to determine whether CAIT will allow objective, real-time pressure monitoring. If high pressure injections are proven to contribute to nerve injury in humans, this technique may have the potential to improve the safety of peripheral nerve blocks.

  11. Optimization of the multi-turn injection efficiency for a medical synchrotron

    NASA Astrophysics Data System (ADS)

    Kim, J.; Yoon, M.; Yim, H.

    2016-09-01

    We present a method for optimizing the multi-turn injection efficiency for a medical synchrotron. We show that for a given injection energy, the injection efficiency can be greatly enhanced by choosing transverse tunes appropriately and by optimizing the injection bump and the number of turns required for beam injection. We verify our study by applying the method to the Korea Heavy Ion Medical Accelerator (KHIMA) synchrotron which is currently being built at the campus of Dongnam Institute of Radiological and Medical Sciences (DIRAMS) in Busan, Korea. First the frequency map analysis was performed with the help of the ELEGANT and the ACCSIM codes. The tunes that yielded good injection efficiency were then selected. With these tunes, the injection bump and the number of turns required for injection were then optimized by tracking a number of particles for up to one thousand turns after injection, beyond which no further beam loss occurred. Results for the optimization of the injection efficiency for proton ions are presented.

  12. Anatomical Basis for Safe and Effective Volumization of the Temple.

    PubMed

    Breithaupt, Andrew D; Jones, Derek H; Braz, Andre; Narins, Rhoda; Weinkle, Susan

    2015-12-01

    One of the earliest but often unaddressed signs of facial aging is volume loss in the temple. Treatment of the area can produce satisfying results for both patient and practitioner. Safe injection requires explicit knowledge of the anatomy to avoid complications related to the multitude of vessels that course throughout the region at various depths. The authors aim to detail the anatomy of the area and provide a safe and easy-to-follow method for injection. The authors review the relevant anatomy of the temporal region and its application to cosmetic filler injections. The authors describe an easy-to-follow approach for a safe and effective injection window based on numerous anatomical studies. Injection in this area is not without risk, including potential blindness. The authors review the potential complications and their treatments. Hollowing of the temple is an early sign of aging that, when corrected, can lead to significant patient and practitioner satisfaction. Proper anatomically knowledge is required to avoid potentially severe complications. In this study, the authors present a reliable technique to safely and effectively augment this often undertreated area of the aging face.

  13. EM reconstruction of dual isotope PET using staggered injections and prompt gamma positron emitters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andreyev, Andriy, E-mail: andriy.andreyev-1@philips.com; Sitek, Arkadiusz; Celler, Anna

    2014-02-15

    Purpose: The aim of dual isotope positron emission tomography (DIPET) is to create two separate images of two coinjected PET radiotracers. DIPET shortens the duration of the study, reduces patient discomfort, and produces perfectly coregistered images compared to the case when two radiotracers would be imaged independently (sequential PET studies). Reconstruction of data from such simultaneous acquisition of two PET radiotracers is difficult because positron decay of any isotope creates only 511 keV photons; therefore, the isotopes cannot be differentiated based on the detected energy. Methods: Recently, the authors have proposed a DIPET technique that uses a combination of radiotracermore » A which is a pure positron emitter (such as{sup 18}F or {sup 11}C) and radiotracer B in which positron decay is accompanied by the emission of a high-energy (HE) prompt gamma (such as {sup 38}K or {sup 60}Cu). Events that are detected as triple coincidences of HE gammas with the corresponding two 511 keV photons allow the authors to identify the lines-of-response (LORs) of isotope B. These LORs are used to separate the two intertwined distributions, using a dedicated image reconstruction algorithm. In this work the authors propose a new version of the DIPET EM-based reconstruction algorithm that allows the authors to include an additional, independent estimate of radiotracer A distribution which may be obtained if radioisotopes are administered using a staggered injections method. In this work the method is tested on simple simulations of static PET acquisitions. Results: The authors’ experiments performed using Monte-Carlo simulations with static acquisitions demonstrate that the combined method provides better results (crosstalk errors decrease by up to 50%) than the positron-gamma DIPET method or staggered injections alone. Conclusions: The authors demonstrate that the authors’ new EM algorithm which combines information from triple coincidences with prompt gammas and staggered injections improves the accuracy of DIPET reconstructions for static acquisitions so they reach almost the benchmark level calculated for perfectly separated tracers.« less

  14. Burst nucleation by hot injection for size controlled synthesis of ε-cobalt nanoparticles.

    PubMed

    Zacharaki, Eirini; Kalyva, Maria; Fjellvåg, Helmer; Sjåstad, Anja Olafsen

    2016-01-01

    Reproducible growth of narrow size distributed ε-Co nanoparticles with a specific size requires full understanding and identification of the role of essential synthesis parameters for the applied synthesis method. For the hot injection methodology, a significant discrepancy with respect to obtained sizes and applied reaction conditions is reported. Currently, a systematic investigation controlling key synthesis parameters as injection-temperature and time, metal to surfactant ratio and reaction holding time in terms of their impact on mean ([Formula: see text]mean) and median ([Formula: see text]median) particle diameter using dichlorobenzene (DCB), Co2(CO)8 and oleic acid (OA) as the reactant matrix is lacking. A series of solution-based ε-Co nanoparticles were synthesized using the hot injection method. Suspensions and obtained particles were analyzed by DLS, ICP-OES, (synchrotron)XRD and TEM. Rietveld refinements were used for structural analysis. Mean ([Formula: see text]mean) and median ([Formula: see text]median) particle diameters were calculated with basis in measurements of 250-500 particles for each synthesis. 95 % bias corrected confidence intervals using bootstrapping were calculated for syntheses with three or four replicas. ε-Co NPs in the size range ~4-10 nm with a narrow size distribution are obtained via the hot injection method, using OA as the sole surfactant. Typically the synthesis yield is ~75 %, and the particles form stable colloidal solutions when redispersed in hexane. Reproducibility of the adopted synthesis procedure on replicate syntheses was confirmed. We describe in detail the effects of essential synthesis parameters, such as injection-temperature and time, metal to surfactant ratio and reaction holding time in terms of their impact on mean ([Formula: see text]mean) and median ([Formula: see text]median) particle diameter. The described synthesis procedure towards ε-Co nanoparticles (NPs) is concluded to be robust when controlling key synthesis parameters, giving targeted particle diameters with a narrow size distribution. We have identified two major synthesis parameters which control particle size, i.e., the metal to surfactant molar ratio and the injection temperature of the hot OA-DCB solution into which the cobalt precursor is injected. By increasing the metal to surfactant molar ratio, the mean particle diameter of the ε-Co NPs has been found to increase. Furthermore, an increase in the injection temperature of the hot OA-DCB solution into which the cobalt precursor is injected, results in a decrease in the mean particle diameter of the ε-Co NPs, when the metal to surfactant molar ratio [Formula: see text] is fixed at ~12.9.

  15. Polydrug use and HIV risk among people who inject heroin in Tijuana, Mexico: A Latent class analysis

    PubMed Central

    Meacham, M.C.; Rudolph, A.E.; Strathdee, S.A.; Rusch, M.L.; Brouwer, K.C.; Patterson, T.L.; Vera, A.; Rangel, G.; Roesch, S.C.

    2016-01-01

    Background Although most people who inject drugs (PWID) in Tijuana, Mexico, primarily inject heroin, injection and non-injection use of methamphetamine and cocaine is common. We examined patterns of polydrug use among heroin injectors to inform prevention and treatment of drug use and its health and social consequences. Methods Participants were PWID residing in Tijuana aged ≥ 18 years who reported heroin injection in the past 6 months and were recruited through respondent driven sampling (n=1025). Latent class analysis was conducted to assign individuals to classes on a probabilistic basis, using four indicators of past 6 month polydrug and polyroute use: cocaine injecting, cocaine smoking or snorting, methamphetamine injecting, methamphetamine smoking or snorting. Latent class membership was regressed onto covariates in a multinomial logistic regression. Results Latent class analyses testing 1, 2, 3, and 4 classes were fit, with the 3-class solution fitting best. Class 1 was defined by predominantly heroin use (50.2%, n=515); class 2 by methamphetamine and heroin use (43.7%, n=448), and class 3 by methamphetamine, cocaine, and heroin use (6.0%, n=62). Bivariate and multivariate analyses indicated a group of methamphetamine and cocaine users that exhibited higher risk sexual practices and lower heroin injecting frequency, and a group of methamphetamine users who were younger and more likely to be female. Conclusions Discrete subtypes of heroin PWID were identified based on methamphetamine and cocaine use patterns. These findings have identified subtypes of heroin injectors who require more tailored interventions to reduce the health and social harms of injecting drug use. PMID:26444185

  16. Administering Multiple Injectable Vaccines During a Single Visit—Summary of Findings From the Accelerated Introduction of Inactivated Polio Vaccine Globally

    PubMed Central

    Patel, Manish; Hampton, Lee M.; Burnett, Eleanor; Ehlman, Daniel C.; Garon, Julie; Cloessner, Emily; Chmielewski, Elizabeth; Hyde, Terri B.; Mantel, Carsten; Wallace, Aaron S.

    2017-01-01

    Abstract Background. In 2013, the World Health Organization’s (WHO’s) Strategic Advisory Group of Experts (SAGE) recommended that all 126 countries using only oral polio vaccine (OPV) introduce at least 1 dose of inactivated polio vaccine (IPV) into their routine immunization schedules by the end of 2015. In many countries, the addition of IPV would necessitate delivery of multiple injectable vaccines (hereafter, “multiple injections”) during a single visit, with infants receiving IPV alongside pentavalent vaccine (which covers diphtheria, tetanus, and whole-cell pertussis; hepatitis B; and Haemophilus influenzae type b) and pneumococcal vaccine. Unanticipated concerns emerged from countries over acceptability of multiple injections, sites of administration, and safety. We contextualized the issues surrounding multiple injections by documenting concerns associated with administration of ≥3 injections, existing evidence in the published literature, and findings of a systematic review on administration practices and techniques. Methods. Concerns associated with multiple-injection visits were documented from meetings and personal communications with immunization program managers. Published literature on the acceptability of multiple injections by providers and caregivers was summarized, and a systematic review of the literature on administration practices was completed on the following topics: spacing between injection sites (ie, vaccine spacing), site of injection, route of injection, and procedural preparedness. WHO and United Nations Children’s Fund data from 2013–2015 were used to assess multiple-injection visits included in national immunization schedules. Results. Healthcare provider and caregiver attitudes and practices indicated concerns about infant pain, potential adverse effects, and uncertainty about vaccine effectiveness with multiple-injection visits. Published literature reinforced the record of safety and acceptance of the recommended schedule of IPV by the SAGE, but the evidence was largely from developed countries. Parental acceptance of multiple injections was associated with a positive provider recommendation to the caregiver. Findings of the systematic review identified that the intramuscular route is preferred over the subcutaneous route for vaccine administration and that the vastus lateralis muscle is preferred over the deltoid muscle for intramuscular injections. Recommendations on vaccine spacing and procedural preparedness were based on practical necessities, but comparative evidence was not identified. During 2013–2015, 85 countries added IPV to their immunization schedules, 46 (55%) of which adopted a schedule resulting in 3 injectable vaccines being administered in a single visit. Conclusion. The multiple-injection experience identified gaps in guidance for future vaccine introductions. Global partner organizations quickly mobilized to assess, document, and communicate the existing global experience on multiple-injection visits. This evidence-based approach provided reassurance to opinion leaders, health workers, and professional societies, thus encouraging uptake of IPV as a second or third injection in an accelerated manner globally. PMID:28838188

  17. Fast batch injection analysis of H(2)O(2) using an array of Pt-modified gold microelectrodes obtained from split electronic chips.

    PubMed

    Pacheco, Bruno D; Valério, Jaqueline; Angnes, Lúcio; Pedrotti, Jairo J

    2011-06-24

    A fast and robust analytical method for amperometric determination of hydrogen peroxide (H(2)O(2)) based on batch injection analysis (BIA) on an array of gold microelectrodes modified with platinum is proposed. The gold microelectrode array (n=14) was obtained from electronic chips developed for surface mounted device technology (SMD), whose size offers advantages to adapt them in batch cells. The effect of the dispensing rate, volume injected, distance between the platinum microelectrodes and the pipette tip, as well as the volume of solution in the cell on the analytical response were evaluated. The method allows the H(2)O(2) amperometric determination in the concentration range from 0.8 μmolL(-1) to 100 μmolL(-1). The analytical frequency can attain 300 determinations per hour and the detection limit was estimated in 0.34 μmolL(-1) (3σ). The anodic current peaks obtained after a series of 23 successive injections of 50 μL of 25 μmolL(-1) H(2)O(2) showed an RSD<0.9%. To ensure the good selectivity to detect H(2)O(2), its determination was performed in a differential mode, with selective destruction of the H(2)O(2) with catalase in 10 mmolL(-1) phosphate buffer solution. Practical application of the analytical procedure involved H(2)O(2) determination in rainwater of São Paulo City. A comparison of the results obtained by the proposed amperometric method with another one which combines flow injection analysis (FIA) with spectrophotometric detection showed good agreement. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Method for controlling corrosion in thermal vapor injection gases

    DOEpatents

    Sperry, John S.; Krajicek, Richard W.

    1981-01-01

    An improvement in the method for producing high pressure thermal vapor streams from combustion gases for injection into subterranean oil producing formations to stimulate the production of viscous minerals is described. The improvement involves controlling corrosion in such thermal vapor gases by injecting water near the flame in the combustion zone and injecting ammonia into a vapor producing vessel to contact the combustion gases exiting the combustion chamber.

  19. Development of an automated flow injection analysis system for determination of phosphate in nutrient solutions.

    PubMed

    Karadağ, Sevinç; Görüşük, Emine M; Çetinkaya, Ebru; Deveci, Seda; Dönmez, Koray B; Uncuoğlu, Emre; Doğu, Mustafa

    2018-01-25

    A fully automated flow injection analysis (FIA) system was developed for determination of phosphate ion in nutrient solutions. This newly developed FIA system is a portable, rapid and sensitive measuring instrument that allows on-line analysis and monitoring of phosphate ion concentration in nutrient solutions. The molybdenum blue method, which is widely used in FIA phosphate analysis, was adapted to the developed FIA system. The method is based on the formation of ammonium Mo(VI) ion by reaction of ammonium molybdate with the phosphate ion present in the medium. The Mo(VI) ion then reacts with ascorbic acid and is reduced to the spectrometrically measurable Mo(V) ion. New software specific for flow analysis was developed in the LabVIEW development environment to control all the components of the FIA system. The important factors affecting the analytical signal were identified as reagent flow rate, injection volume and post-injection flow path length, and they were optimized using Box-Behnken experimental design and response surface methodology. The optimum point for the maximum analytical signal was calculated as 0.50 mL min -1 reagent flow rate, 100 µL sample injection volume and 60 cm post-injection flow path length. The proposed FIA system had a sampling frequency of 100 samples per hour over a linear working range of 3-100 mg L -1 (R 2  = 0.9995). The relative standard deviation (RSD) was 1.09% and the limit of detection (LOD) was 0.34 mg L -1 . Various nutrient solutions from a tomato-growing hydroponic greenhouse were analyzed with the developed FIA system and the results were found to be in good agreement with vanadomolybdate chemical method findings. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  20. Spectral-element simulations of carbon dioxide (CO2) sequestration time-lapse monitoring

    NASA Astrophysics Data System (ADS)

    Morency, C.; Luo, Y.; Tromp, J.

    2009-12-01

    Geologic sequestration of CO2, a green house gas, represents an effort to reduce the large amount of CO2 generated as a by-product of fossil fuels combustion and emitted into the atmosphere. This process of sequestration involves CO2 storage deep underground. There are three main storage options: injection into hydrocarbon reservoirs, injection into methane-bearing coal beds, or injection into deep saline aquifers, that is, highly permeable porous media. The key issues involve accurate monitoring of the CO2, from the injection stage to the prediction & verification of CO2 movement over time for environmental considerations. A natural non-intrusive monitoring technique is referred to as ``4D seismics'', which involves 3D time-lapse seismic surveys. The success of monitoring the CO2 movement is subject to a proper description of the physics of the problem. We propose to realize time-lapse migrations comparing acoustic, elastic, and poroelastic simulations of 4D seismic imaging to characterize the storage zone. This approach highlights the influence of using different physical theories on interpreting seismic data, and, more importantly, on extracting the CO2 signature from the seismic wave field. Our simulations are performed using a spectral-element method, which allows for highly accurate results. Biot's equations are implemented to account for poroelastic effects. Attenuation associated with the anelasticity of the rock frame and frequency-dependent viscous resistance of the pore fluid are accommodated based upon a memory variable approach. The sensitivity of observables to the model parameters is quantified based upon finite-frequency sensitivity kernels calculated using an adjoint method.

  1. Time-lapse ERT interpretation methodology for leachate injection monitoring based on multiple inversions and a clustering strategy (MICS)

    NASA Astrophysics Data System (ADS)

    Audebert, M.; Clément, R.; Touze-Foltz, N.; Günther, T.; Moreau, S.; Duquennoi, C.

    2014-12-01

    Leachate recirculation is a key process in municipal waste landfills functioning as bioreactors. To quantify the water content and to assess the leachate injection system, in-situ methods are required to obtain spatially distributed information, usually electrical resistivity tomography (ERT). This geophysical method is based on the inversion process, which presents two major problems in terms of delimiting the infiltration area. First, it is difficult for ERT users to choose an appropriate inversion parameter set. Indeed, it might not be sufficient to interpret only the optimum model (i.e. the model with the chosen regularisation strength) because it is not necessarily the model which best represents the physical process studied. Second, it is difficult to delineate the infiltration front based on resistivity models because of the smoothness of the inversion results. This paper proposes a new methodology called MICS (multiple inversions and clustering strategy), which allows ERT users to improve the delimitation of the infiltration area in leachate injection monitoring. The MICS methodology is based on (i) a multiple inversion step by varying the inversion parameter values to take a wide range of resistivity models into account and (ii) a clustering strategy to improve the delineation of the infiltration front. In this paper, MICS was assessed on two types of data. First, a numerical assessment allows us to optimise and test MICS for different infiltration area sizes, contrasts and shapes. Second, MICS was applied to a field data set gathered during leachate recirculation on a bioreactor.

  2. Promethazine Misuse among Methadone Maintenance Patients and Community-Based Injection Drug Users

    PubMed Central

    Shapiro, Brad J.; Lynch, Kara L.; Toochinda, Tab; Lutnick, Alexandra; Cheng, Helen Y.; Kral, Alex H.

    2013-01-01

    Objective Promethazine has been reported to be misused in conjunction with opioids in several settings. Promethazine misuse by itself or in conjunction with opioids may have serious adverse health effects. To date, no prevalence data for the nonmedical use of promethazine has been reported. This study examines the prevalence and correlates of promethazine use in two different populations in San Francisco, California, USA: methadone maintenance clinic patients and community-based injection drug users (IDUs). Methods We analyzed urine samples for the presence of promethazine and reviewed the clinical records for 334 methadone maintenance patients at the county methadone clinic. Separately, we used targeted sampling methods to recruit and survey 139 community-based opioid IDUs about their use of promethazine. We assessed prevalence and factors associated with promethazine use with bivariate and multivariate statistics. Results The prevalence of promethazine positive urine samples among the methadone maintenance patients was 26 percent. Only 15 percent of promethazine positive patients had an active prescription for promethazine. Among IDUs reporting injection of opiates in the community-based survey, 17 percent reported having used promethazine in the past month; 24 percent of the IDUs who reported being enrolled in methadone treatment reported using promethazine in the past month. Conclusions The finding that one quarter of methadone maintenance patients in a clinic or recruited in community settings have recently used promethazine provides compelling evidence of significant nonmedical use of promethazine in this patient population. Further research is needed to establish the extent and nature of nonmedical use of promethazine. PMID:23385449

  3. Sobol‧ sensitivity analysis of NAPL-contaminated aquifer remediation process based on multiple surrogates

    NASA Astrophysics Data System (ADS)

    Luo, Jiannan; Lu, Wenxi

    2014-06-01

    Sobol‧ sensitivity analyses based on different surrogates were performed on a trichloroethylene (TCE)-contaminated aquifer to assess the sensitivity of the design variables of remediation duration, surfactant concentration and injection rates at four wells to remediation efficiency First, the surrogate models of a multi-phase flow simulation model were constructed by applying radial basis function artificial neural network (RBFANN) and Kriging methods, and the two models were then compared. Based on the developed surrogate models, the Sobol‧ method was used to calculate the sensitivity indices of the design variables which affect the remediation efficiency. The coefficient of determination (R2) and the mean square error (MSE) of these two surrogate models demonstrated that both models had acceptable approximation accuracy, furthermore, the approximation accuracy of the Kriging model was slightly better than that of the RBFANN model. Sobol‧ sensitivity analysis results demonstrated that the remediation duration was the most important variable influencing remediation efficiency, followed by rates of injection at wells 1 and 3, while rates of injection at wells 2 and 4 and the surfactant concentration had negligible influence on remediation efficiency. In addition, high-order sensitivity indices were all smaller than 0.01, which indicates that interaction effects of these six factors were practically insignificant. The proposed Sobol‧ sensitivity analysis based on surrogate is an effective tool for calculating sensitivity indices, because it shows the relative contribution of the design variables (individuals and interactions) to the output performance variability with a limited number of runs of a computationally expensive simulation model. The sensitivity analysis results lay a foundation for the optimal groundwater remediation process optimization.

  4. Determination of ammonia and greenhouse gas emissions from land application of swine slurry: a comparison of three application methods.

    PubMed

    Lovanh, Nanh; Warren, Jason; Sistani, Karamat

    2010-03-01

    In this study, the comparison and monitoring of the initial greenhouse gas (GHG) emissions using a flux chamber and gas analyzer from three different liquid manure application methods at a swine farm in Kentucky were carried out. Swine slurry was applied to farmland by row injection, surface spray, and Aerway injection. Ammonia and GHG concentrations were monitored immediately after application, 72 and 216h after application. The results showed that the initial ammonia flux ranged from 5.80 mg m(-2)h(-1) for the surface spray method to 1.80 mg m(-2)h(-1) for the row injection method. The initial fluxes of methane ranged from 8.75 mg m(-2)h(-1) for surface spray to 2.27 mg m(-2)h(-1) for Aerway injection, carbon dioxide ranged from 4357 mg m(-2)h(-1) for surface spray to 60 mg m(-2)h(-1) for row injection, and nitrous oxide ranged from 0.89 mg m(-2)h(-1) for surface spray to 0.22 mg m(-2)h(-1) for row injection. However, the Aerway injection method seemed to create the highest gas (GHG) concentrations inside the monitoring chambers at the initial application and produced the highest gas fluxes at subsequent sampling time (e.g., 72h after application). Nevertheless, the surface spray method appeared to produce the highest gas fluxes, and the row injection method appeared to emit the least amount of greenhouse gases into the atmosphere. Gas fluxes decreased over time and did not depend on the initial headspace concentration in the monitoring flux chambers. Published by Elsevier Ltd.

  5. METHODS FOR DETERMINING THE MECHANICAL INTEGRITY OF CLASS II INJECTION WELLS

    EPA Science Inventory

    The mechanical integrity of injection wells must be determined to insure that there is no significant leak in the casing, tubing or packer, and that there is no significant fluid movement through vertical channels adjacent to the injection well. Methods for mechanical integrity t...

  6. Numerical simulations of negatively buoyant jets in an immiscible fluid using the Particle Finite Element Method

    NASA Astrophysics Data System (ADS)

    Mier-Torrecilla, Monica; Geyer, Adelina; Phillips, Jeremy C.; Idelsohn, Sergio R.; Oñate, Eugenio

    2010-05-01

    In this work we investigate numerically the injection of a negatively buoyant jet into a homogenous immiscible ambient fluid using the Particle Finite Element Method (PFEM), a newly developed tool that combines the flexibility of particle-based methods with the accuracy of the finite element discretization. In order to test the applicability of PFEM to the study of negatively buoyant jets, we have compared the two-dimensional numerical results with experiments investigating the injection of a jet of dyed water through a nozzle in the base of a cylindrical tank containing rapeseed oil. In both simulations and experiments, the fountain inlet flow velocity and nozzle diameter were varied to cover a wide range of Reynolds Re and Froude numbers Fr, such that 0.1 < Fr < 30, reproducing both weak and strong fountains in a laminar regime (8 < Re < 1350). Numerical results, together with the experimental observations, allow us to describe three different fountain behaviors that have not been previously reported. Based on the Re and Fr values for the numerical and experimental simulations, we have built a regime map to define how these values may control the occurrence of each of the observed flow types. Whereas the Fr number itself provides a prediction of the maximum penetration height of the jet, its combination with the Re number provides a prediction of the flow behavior for a specific nozzle diameter and injection velocity. Conclusive remarks concerning the dynamics of negatively buoyant jets may be applied later on to several geological situations, e.g. the flow structure of a fully submerged subaqueous eruptive vent discharging magma or the replenishment of magma chambers in the Earth's crust.

  7. Process influences and correction possibilities for high precision injection molded freeform optics

    NASA Astrophysics Data System (ADS)

    Dick, Lars; Risse, Stefan; Tünnermann, Andreas

    2016-08-01

    Modern injection molding processes offer a cost-efficient method for manufacturing high precision plastic optics for high volume applications. Besides form deviation of molded freeform optics, internal material stress is a relevant influencing factor for the functionality of a freeform optics in an optical system. This paper illustrates dominant influence parameters of an injection molding process relating to form deviation and internal material stress based on a freeform demonstrator geometry. Furthermore, a deterministic and efficient way for 3D mold correcting of systematic, asymmetrical shrinkage errors is shown to reach micrometer range shape accuracy at diameters up to 40 mm. In a second case, a stress-optimized parameter combination using unusual molding conditions was 3D corrected to reach high precision and low stress freeform polymer optics.

  8. Microbial enhanced oil recovery and compositions therefor

    DOEpatents

    Bryant, Rebecca S.

    1990-01-01

    A method is provided for microbial enhanced oil recovery, wherein a combination of microorganisms is empirically formulated based on survivability under reservoir conditions and oil recovery efficiency, such that injection of the microbial combination may be made, in the presence of essentially only nutrient solution, directly into an injection well of an oil bearing reservoir having oil present at waterflood residual oil saturation concentration. The microbial combination is capable of displacing residual oil from reservoir rock, which oil may be recovered by waterflooding without causing plugging of the reservoir rock. Further, the microorganisms are capable of being transported through the pores of the reservoir rock between said injection well and associated production wells, during waterflooding, which results in a larger area of the reservoir being covered by the oil-mobilizing microorganisms.

  9. Jet-noise reduction through liquid-base foam injection.

    NASA Technical Reports Server (NTRS)

    Manson, L.; Burge, H. L.

    1971-01-01

    An experimental investigation has been made of the sound-absorbing properties of liquid-base foams and of their ability to reduce jet noise. Protein, detergent, and polymer foaming agents were used in water solutions. A method of foam generation was developed to permit systematic variation of the foam density. The investigation included measurements of sound-absorption coefficents for both plane normal incidence waves and diffuse sound fields. The intrinsic acoustic properties of foam, e.g., the characteristic impedance and the propagation constant, were also determined. The sound emitted by a 1-in.-diam cold nitrogen jet was measured for subsonic (300 m/sec) and supersonic (422 m/sec) jets, with and without foam injection. Noise reductions up to 10 PNdB were measured.

  10. Injection characteristics study of high-pressure direct injector for Compressed Natural Gas (CNG) using experimental and analytical method

    NASA Astrophysics Data System (ADS)

    Taha, Z.; Rahim, MF Abdul; Mamat, R.

    2017-10-01

    The injection characteristics of direct injector affect the mixture formation and combustion processes. In addition, the injector is converted from gasoline operation for CNG application. Thus measurement of CNG direct injector mass flow rate was done by independently tested a single injector on a test bench. The first case investigated the effect of CNG injection pressure and the second case evaluate the effect of pulse-width of injection duration. An analytical model was also developed to predict the mass flow rate of the injector. The injector was operated in a choked condition in both the experiments and simulation studies. In case 1, it was shown that mass flow rate through the injector is affected by injection pressure linearly. Based on the tested injection pressure of 20 bar to 60 bar, the resultant mass flow rate are in the range of 0.4 g/s to 1.2 g/s which are met with theoretical flow rate required by the engine. However, in Case 2, it was demonstrated that the average mass flow rate at short injection durations is lower than recorded in Case 1. At injection pressure of 50 bar, the average mass flow rate for Case 2 and Case 1 are 0.7 g/s and 1.1 g/s respectively. Also, the measured mass flow rate at short injection duration showing a fluctuating data in the range of 0.2 g/s - 1.3 g/s without any noticeable trends. The injector model able to predict the trend of the mass flow rate at different injection pressure but unable to track the fluctuating trend at short injection duration.

  11. Tolerability and efficacy of newly developed penile injection of cross-linked dextran and polymethylmethacrylate mixture on penile enhancement: 6 months follow-up.

    PubMed

    Yang, D Y; Lee, W K; Kim, S C

    2013-05-01

    Cross-linked dextran and polymethylmethacrylate mixture (Lipen-10) is newly developed tissue filler. The purpose of this study was to evaluate tolerability and efficacy of Lipen-10 on penile enhancement. Twenty adult males were included in this study. Lipen-10 was injected into the subcutaneous tissue of the penile shaft. The penile girth and length were measured in the flaccid state, before and 1, 3 and 6 months after the injection. The circumference increased by 3.7±1.2 cm (50.8%, P<0.0001) at penile base, 4.2±0.9 cm (59.0%, P<0.001) at mid-shaft, and 3.8±1.0 cm (53.2%, P<0.0001) at distal shaft and the length increased by 2.3±1.4 cm (63.2%, P<0.001). There was, however, no significant difference between 3 and 6 months post-treatment in girth and length (P-values: 0.796, 0.498, 0.600 and 0.084 for penile base, mid- and distal-shaft and length, respectively). The complications were only one mild asymmetry of penile shape and one 5-mm-sized nodule in the injected site. There were no clinically significant adverse events in all subjects. Penile injection of Lipen-10 led to a significant increase in penile size, showed a good durability and was well-tolerated, without serious adverse events. These results suggest that penile injection of Lipen-10 may be a new effective method for penile enhancement.

  12. Autoinjectors Preferred for Intramuscular Epinephrine in Anaphylaxis and Allergic Reactions

    PubMed Central

    Campbell, Ronna L.; Bellolio, M. Fernanda; Motosue, Megan S.; Sunga, Kharmene L.; Lohse, Christine M.; Rudis, Maria I.

    2016-01-01

    Introduction Epinephrine is the treatment of choice for anaphylaxis. We surveyed emergency department (ED) healthcare providers regarding two methods of intramuscular (IM) epinephrine administration (autoinjector and manual injection) for the management of anaphylaxis and allergic reactions and identified provider perceptions and preferred method of medication delivery. Methods This observational study adhered to survey reporting guidelines. It was performed through a Web-based survey completed by healthcare providers at an academic ED. The primary outcomes were assessment of provider perceptions and identification of the preferred IM epinephrine administration method by ED healthcare providers. Results Of 217 ED healthcare providers invited to participate, 172 (79%) completed the survey. Overall, 82% of respondents preferred the autoinjector method of epinephrine administration. Providers rated the autoinjector method more favorably for time required for training, ease of use, convenience, satisfaction with weight-based dosing, risk of dosing errors, and speed of administration (p<0.001 for all comparisons). However, manual injection use was rated more favorably for risk of provider self-injury and patient cost (p<0.001 for both comparisons). Three participants (2%) reported a finger stick injury from an epinephrine autoinjector. Conclusion ED healthcare providers preferred the autoinjector method of IM epinephrine administration for the management of anaphylaxis or allergic reactions. Epinephrine autoinjector use may reduce barriers to epinephrine administration for the management of anaphylaxis in the ED. PMID:27833688

  13. Methodology for extraction of space charge density profiles at nanoscale from Kelvin probe force microscopy measurements.

    PubMed

    Villeneuve-Faure, C; Boudou, L; Makasheva, K; Teyssedre, G

    2017-12-15

    To understand the physical phenomena occurring at metal/dielectric interfaces, determination of the charge density profile at nanoscale is crucial. To deal with this issue, charges were injected applying a DC voltage on lateral Al-electrodes embedded in a SiN x thin dielectric layer. The surface potential induced by the injected charges was probed by Kelvin probe force microscopy (KPFM). It was found that the KPFM frequency mode is a better adapted method to probe accurately the charge profile. To extract the charge density profile from the surface potential two numerical approaches based on the solution to Poisson's equation for electrostatics were investigated: the second derivative model method, already reported in the literature, and a new 2D method based on the finite element method (FEM). Results highlight that the FEM is more robust to noise or artifacts in the case of a non-flat initial surface potential. Moreover, according to theoretical study the FEM appears to be a good candidate for determining charge density in dielectric films with thicknesses in the range from 10 nm to 10 μm. By applying this method, the charge density profile was determined at nanoscale, highlighting that the charge cloud remains close to the interface.

  14. Detecting sulphate aerosol geoengineering with different methods

    DOE PAGES

    Lo, Y. T. Eunice; Charlton-Perez, Andrew J.; Lott, Fraser C.; ...

    2016-12-15

    Sulphate aerosol injection has been widely discussed as a possible way to engineer future climate. Monitoring it would require detecting its effects amidst internal variability and in the presence of other external forcings. Here, we investigate how the use of different detection methods and filtering techniques affects the detectability of sulphate aerosol geoengineering in annual-mean global-mean near-surface air temperature. This is done by assuming a future scenario that injects 5 Tg yr -1 of sulphur dioxide into the stratosphere and cross-comparing simulations from 5 climate models. 64% of the studied comparisons would require 25 years or more for detection whenmore » no filter and the multi-variate method that has been extensively used for attributing climate change are used, while 66% of the same comparisons would require fewer than 10 years for detection using a trend-based filter. This then highlights the high sensitivity of sulphate aerosol geoengineering detectability to the choice of filter. With the same trend-based filter but a non-stationary method, 80% of the comparisons would require fewer than 10 years for detection. This does not imply sulphate aerosol geoengineering should be deployed, but suggests that both detection methods could be used for monitoring geoengineering in global, annual mean temperature should it be needed.« less

  15. Designing optimal stimuli to control neuronal spike timing

    PubMed Central

    Packer, Adam M.; Yuste, Rafael; Paninski, Liam

    2011-01-01

    Recent advances in experimental stimulation methods have raised the following important computational question: how can we choose a stimulus that will drive a neuron to output a target spike train with optimal precision, given physiological constraints? Here we adopt an approach based on models that describe how a stimulating agent (such as an injected electrical current or a laser light interacting with caged neurotransmitters or photosensitive ion channels) affects the spiking activity of neurons. Based on these models, we solve the reverse problem of finding the best time-dependent modulation of the input, subject to hardware limitations as well as physiologically inspired safety measures, that causes the neuron to emit a spike train that with highest probability will be close to a target spike train. We adopt fast convex constrained optimization methods to solve this problem. Our methods can potentially be implemented in real time and may also be generalized to the case of many cells, suitable for neural prosthesis applications. With the use of biologically sensible parameters and constraints, our method finds stimulation patterns that generate very precise spike trains in simulated experiments. We also tested the intracellular current injection method on pyramidal cells in mouse cortical slices, quantifying the dependence of spiking reliability and timing precision on constraints imposed on the applied currents. PMID:21511704

  16. Methodology for extraction of space charge density profiles at nanoscale from Kelvin probe force microscopy measurements

    NASA Astrophysics Data System (ADS)

    Villeneuve-Faure, C.; Boudou, L.; Makasheva, K.; Teyssedre, G.

    2017-12-01

    To understand the physical phenomena occurring at metal/dielectric interfaces, determination of the charge density profile at nanoscale is crucial. To deal with this issue, charges were injected applying a DC voltage on lateral Al-electrodes embedded in a SiN x thin dielectric layer. The surface potential induced by the injected charges was probed by Kelvin probe force microscopy (KPFM). It was found that the KPFM frequency mode is a better adapted method to probe accurately the charge profile. To extract the charge density profile from the surface potential two numerical approaches based on the solution to Poisson’s equation for electrostatics were investigated: the second derivative model method, already reported in the literature, and a new 2D method based on the finite element method (FEM). Results highlight that the FEM is more robust to noise or artifacts in the case of a non-flat initial surface potential. Moreover, according to theoretical study the FEM appears to be a good candidate for determining charge density in dielectric films with thicknesses in the range from 10 nm to 10 μm. By applying this method, the charge density profile was determined at nanoscale, highlighting that the charge cloud remains close to the interface.

  17. Polymer and small molecule based hybrid light source

    DOEpatents

    Choong, Vi-En; Choulis, Stelios; Krummacher, Benjamin Claus; Mathai, Mathew; So, Franky

    2010-03-16

    An organic electroluminescent device, includes: a substrate; a hole-injecting electrode (anode) coated over the substrate; a hole injection layer coated over the anode; a hole transporting layer coated over the hole injection layer; a polymer based light emitting layer, coated over the hole transporting layer; a small molecule based light emitting layer, thermally evaporated over the polymer based light emitting layer; and an electron-injecting electrode (cathode) deposited over the electroluminescent polymer layer.

  18. A randomised controlled comparison of injection, thermal, and mechanical endoscopic methods of haemostasis on mesenteric vessels

    PubMed Central

    Hepworth, C; Kadirkamanathan, S; Gong, F; Swain, C

    1998-01-01

    Background and aims—A randomised controlled comparison of haemostatic efficacy of mechanical, injection, and thermal methods of haemostasis was undertaken using canine mesenteric vessels to test the hypothesis that mechanical methods of haemostasis are more effective in controlling haemorrhage than injection or thermal methods. The diameter of arteries in human bleeding ulcers measures up to 3.45 mm; mesenteric vessels up to 5 mm were therefore studied. 
Methods—Mesenteric vessels were randomised to treatment with injection sclerotherapy (adrenaline and ethanolamine), bipolar diathermy, or mechanical methods (band, clips, sewing machine, endoloops). The vessels were severed and haemostasis recorded. 
Results—Injection sclerotherapy and clips failed to stop bleeding from vessels of 1 mm (n=20) and 2 mm (n=20). Bipolar diathermy was effective on 8/10 vessels of 2 mm but failed on 3 mm vessels (n=5). Unstretched elastic bands succeeded on 13/15 vessels of 2 mm but on only 3/10 vessels of 3 mm. The sewing machine achieved haemostasis on 8/10 vessels of 4 mm but failed on 5 mm vessels (n=5); endoloops were effective on all 5 mm vessels (n=5). 
Conclusions—Only mechanical methods were effective on vessels greater than 2 mm in diameter. Some mechanical methods (banding and clips) were less effective than expected and need modification. Thermal and (effective) mechanical methods were significantly (p<0.01) more effective than injection sclerotherapy. The most effective mechanical methods were significantly more effective (p<0.01) than thermal or injection on vessels greater than 2mm. 

 Keywords: endoscopic haemostasis; mesenteric vessels PMID:9616305

  19. Determination of acrylamide in drinking water by large-volume direct injection and ion-exclusion chromatography-mass spectrometry.

    PubMed

    Cavalli, S; Polesello, S; Saccani, G

    2004-06-11

    Acrylamide, a known neurotoxin and putative human carcinogen, has been included among the substances to be monitored in drinking water according to the European Union Directive 98/83 on potable water. This paper reports a new method based on the combination of ion-exclusion chromatographic separation and MS detection. Samples of drinking water have been directly injected in the microbore ICE-AS1 column and detected in the selected-ion monitoring mode by a single quadrupole system with electrospray ionization. Chromatographic conditions, such as eluent composition and flow rate, have been optimized by a central composite design experiment. Statistical analysis of data showed that the amount of acetonitrile fraction in the eluent mixture, composed by acetonitrile and formic acid solution, is the variable that most influences retention of the acrylamide peak. After optimization of MS detection parameters, this method has been validated for spiked drinking water samples. The effect of large-volume injection (up to 500 microl) has been also explored. Linearity was evaluated from 0.5 to 5 microg l(-1). Repeatability, expressed as R.S.D., was 16 and 12% at 0.5 and 1 microg l(-1) respectively. The limit of detection was 0.20 ppb with 500 microl injection volume.

  20. Functionalizable hydrogel microparticles of tunable size and stiffness for soft-tissue filler applications

    PubMed Central

    Chan, Ka Man Carmen; Li, Randolph H.; Chapman, Joseph W.; Trac, Eric M.; Kobler, James B.; Zeitels, Steven M.; Langer, Robert; Karajanagi, Sandeep S.

    2014-01-01

    Particle size, stiffness and surface functionality are important in determining the injection site, safety and efficacy of injectable soft-tissue fillers. Methods to produce soft injectable biomaterials with controlled particle characteristics are therefore desirable. Here we report a method based on suspension photopolymerization and semi-interpenetrating network (semi-IPN) to synthesize soft, functionalizable, spherical hydrogel microparticles (MP) of independently tunable size and stiffness. MP were prepared using acrylated forms of polyethylene glycol (PEG), gelatin and hyaluronic acid. Semi-IPN MP of PEG-diacrylate and PEG were used to study the effect of process parameters on particle characteristics. The process parameters were systematically varied to produce MP with size ranging from 115 to 515 μm and stiffness ranging from 190 to 1600 Pa. In vitro studies showed that the MP thus prepared were cytocompatible. The ratio and identity of the polymers used to make the semi-IPN MP were varied to control their stiffness and to introduce amine groups for potential functionalization. Slow-release polymeric particles loaded with Rhodamine or dexamethasone were incorporated in the MP as a proof-of-principle of drug incorporation and release from the MP. This work has implications in preparing injectable biomaterials of natural or synthetic polymers for applications as soft-tissue fillers. PMID:24561708

  1. Estimation of the quantification uncertainty from flow injection and liquid chromatography transient signals in inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Laborda, Francisco; Medrano, Jesús; Castillo, Juan R.

    2004-06-01

    The quality of the quantitative results obtained from transient signals in high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) and flow injection-inductively coupled plasma mass spectrometry (FI-ICPMS) was investigated under multielement conditions. Quantification methods were based on multiple-point calibration by simple and weighted linear regression, and double-point calibration (measurement of the baseline and one standard). An uncertainty model, which includes the main sources of uncertainty from FI-ICPMS and HPLC-ICPMS (signal measurement, sample flow rate and injection volume), was developed to estimate peak area uncertainties and statistical weights used in weighted linear regression. The behaviour of the ICPMS instrument was characterized in order to be considered in the model, concluding that the instrument works as a concentration detector when it is used to monitorize transient signals from flow injection or chromatographic separations. Proper quantification by the three calibration methods was achieved when compared to reference materials, although the double-point calibration allowed to obtain results of the same quality as the multiple-point calibration, shortening the calibration time. Relative expanded uncertainties ranged from 10-20% for concentrations around the LOQ to 5% for concentrations higher than 100 times the LOQ.

  2. Passive Acoustic Leak Detection for Sodium Cooled Fast Reactors Using Hidden Markov Models

    NASA Astrophysics Data System (ADS)

    Marklund, A. Riber; Kishore, S.; Prakash, V.; Rajan, K. K.; Michel, F.

    2016-06-01

    Acoustic leak detection for steam generators of sodium fast reactors have been an active research topic since the early 1970s and several methods have been tested over the years. Inspired by its success in the field of automatic speech recognition, we here apply hidden Markov models (HMM) in combination with Gaussian mixture models (GMM) to the problem. To achieve this, we propose a new feature calculation scheme, based on the temporal evolution of the power spectral density (PSD) of the signal. Using acoustic signals recorded during steam/water injection experiments done at the Indira Gandhi Centre for Atomic Research (IGCAR), the proposed method is tested. We perform parametric studies on the HMM+GMM model size and demonstrate that the proposed method a) performs well without a priori knowledge of injection noise, b) can incorporate several noise models and c) has an output distribution that simplifies false alarm rate control.

  3. Determination of Trace Amounts of Chromium(III) in Water Samples Using Online Flow Injection Catalytic Spectrophotometry

    NASA Astrophysics Data System (ADS)

    Zhao, Z. X.; Zhang, X. S.

    2017-01-01

    A new online flow injection spectrophotometric method for the determination of trivalent chromium was developed. This method is based on the property of trivalent chromium to be a catalyst for the oxidation of Indigo Carmine (IC) with potassium periodate and to lose its color in the presence of ethylenediaminetetraacetic acid and sodium tripolyphosphate. It was shown that Tween-20 serves as an additional accelerator of the catalytic oxidation. The linear dynamic range of the determination of Cr(III) was 1-40.0 μg/L, while the limit of detection was 0.05 μg/L. The correlation coefficient r was 0.998, while the relative standard deviation for 5 μg/L of the Cr(III) solution was 3.83%. The feasibility of this method was checked by its application to trivalent chromium determination in real water samples.

  4. [Flow injection biamperometric analysis of isoniazid].

    PubMed

    Zhang, J C; Zhao, C; Song, J F

    2001-09-01

    To establish a simple, rapid, and accurate electrochemical method for on-line determination of isoniazid. Based on the flow injection biamperometry for irreversible couple system, and using two preanodized platinum electrodes with the applied potential difference of 0 V, the biamperometric method for the determination of isoniazid has been proposed by coupling the catalytic oxidation of isoniazid and the reduction of platinum oxide. Common excipients, inorganic ions, amino acids, vitamins and proteins do not interfere with the determination. Linear relationship between current and the concentration of isoniazid is obtained in the range of 1.0 x 10(-6)-1.0 x 10(-4) mol.L-1 (gamma = 0.998, n = 11). The RSD of 1.8% was obtained for 8 successive determinations of 1.0 x 10(-5) mol.L-1 isoniazid. The proposed method has been shown to be sensitive, selective, rapid (120 samples.h-1), and suitable for the on-line direct determination of isoniazid.

  5. The time-adjusted gradual replacement injection method enables better visualization of the right heart.

    PubMed

    Nakahara, Takehiro; Jinzaki, Masahiro; Niwamae, Nogiku; Saito, Yuuichirou; Arai, Masashi; Tsushima, Yoshito; Kuribayashi, Sachio; Kurabayashi, Masahiko

    2014-01-01

    Despite the improvement of cardiac CT, right heart visualization remains challenging. We herein describe a new method, called the time-adjusted gradual replacement injection protocol. The aim of this study was to compare this protocol with the split-bolus injection protocol. Fifty-two patients who had undergone dual-source cardiac CT were retrospectively recruited. Twenty-six patients were injected by using the split-bolus injection protocol, and 26 patients were injected by using the time-adjusted gradual replacement injection protocol. For this method, we injected contrast medium for 10 seconds at a flow rate of 0.07 × body weight mL/s, then gradually replaced the contrast material with saline until 2 seconds before finishing the scans. The CT attenuation was measured in 4 chambers, the aorta, and the coronary arteries. The visualization of the anatomic structures and the occurrence and severity of streak artifacts were scored for the cardiac structures in the heart. For the analyses, either Welch t-test or Student t-test was performed. In the right heart, the CT values and visualization scores were significantly higher in the time-adjusted replacement injection group than in the split-bolus injection group, whereas the artifact scores were comparable between the 2 groups. The CT values, visualization scores, and artifact scores of the left heart were not significantly different between the 2 groups. In this study, the time-adjusted gradual replacement injection protocol provided excellent attenuation for visualization of the right heart. This method may help to accurately evaluate the right cardiac anatomy and thereby identify any potential diseases. Copyright © 2014 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  6. Differential experiences of Mexican policing by people who inject drugs residing in Tijuana and San Diego

    PubMed Central

    Wood, Emily F.; Werb, Dan; Beletsky, Leo; Rangel, Gudelia; Mota, Jazmine Cuevas; Garfein, Richard S.; Strathdee, Steffanie A.; Wagner, Karla D.

    2017-01-01

    Background Research among people who inject drugs (PWIDs) in the USA and Mexico has identified a range of adverse health impacts associated with policing of PWIDs. We employed a mixed methods design to investigate how PWIDs from San Diego and Mexico experienced policing in Tijuana, and how these interactions affect PWIDs behavior, stratifying by country of origin. Methods In 2012–2014, 575 PWIDs in San Diego, 102 of whom had used drugs in Mexico in the past six months, were enrolled in the STAHR-II study, with qualitative interviews conducted with a subsample of 20 who had recently injected drugs in Mexico. During this period, 735 PWIDs in Tijuana were also enrolled in the El Cuete-IV study, with qualitative interviews conducted with a subsample of 20 recently stopped by police. We calculated descriptive statistics for quantitative variables and conducted thematic analysis of qualitative transcripts. Integration of these data involved comparing frequencies across cohorts and using qualitative themes to explain and explore findings. Results Sixty-one percent of San Diego-based participants had been recently stopped by law enforcement officers (LEOs) in Mexico; 53% reported it was somewhat or very likely that they would be arrested while in Mexico because they look like a drug user. Ninety percent of Tijuana-based participants had been recently stopped by LEOs; 84% reported it was somewhat or very likely they could get arrested because they look like a drug user. Participants in both cohorts described bribery and targeting by LEOs in Mexico. However, most San Diego-based participants described compliance with bribery as a safeguard against arrest and detention, with mistreatment being rare. Tijuana-based participants described being routinely targeted by LEOs, were frequently detained, and reported instances of sexual and physical violence. Tijuana-based participants described modifying how, where, and with whom they injected drugs in response; and experienced feelings of stress, anxiety, and powerlessness. This was less common among San Diego-based participants, who mostly attempted to avoid contact with LEOs in Mexico while engaging in risky injection behavior. Conclusion Experiences of discrimination and stigma were reported by a larger proportion of PWIDs living in Mexico, suggesting that they may be subject to greater health harms related to policing practices compared with those residing in the USA. Our findings reinforce the importance of efforts to curb abuse and align policing practices with public health goals in both the US and Mexico. PMID:28111221

  7. 'It's Fast, It's Quick, It Stops Me Being Sick': How to influence preparation of opioid tablets for injection.

    PubMed

    Lafferty, Lise; Treloar, Carla; van Breda, Nick; Steele, Maureen; Hiley, Sarah; Flaherty, Ian; Salmon, Allison

    2017-09-01

    Injection of pharmaceutical opioids (PO) among people who inject drugs has increased in many countries. The common method for preparing PO tablets for injection uses heat, resulting in greater particulate matter and therefore increased risk of local infection risk and damage to veins and organs. A cold preparation process has fewer risks, but this preparation method is not commonly used. This study seeks to explore how people who inject PO learn to prepare injections and how health promotion efforts could influence practice. Between March and December 2013, qualitative interviews were undertaken with 33 clients of Sydney's Medically Supervised Injecting Centre who inject PO tablets regarding sources of knowledge and current preparation methods for injection of POs. Overwhelmingly, the most commonly reported source of knowledge around injection of tablets was others who inject. Most participants reported heating the solution as the quickest way to administer the drug. Attitudes to the use of wheel filters varied, with some participants reporting that they would use the filters if they were shown how, while others reported a number of barriers to using filters, including complexity of use. Harnessing the power of social connections may provide avenues for education about safer injecting of tablets, including the use of wheel filters. Further work is required to debunk myths about the relative potencies of cold versus hot drug solution. Collaborations between harm reduction workers and peer workers would assist in knowledge dissemination regarding safer injecting practices. © 2017 Australasian Professional Society on Alcohol and other Drugs.

  8. Eos modeling and reservoir simulation study of bakken gas injection improved oil recovery in the elm coulee field, Montana

    NASA Astrophysics Data System (ADS)

    Pu, Wanli

    The Bakken Formation in the Williston Basin is one of the most productive liquid-rich unconventional plays. The Bakken Formation is divided into three members, and the Middle Bakken Member is the primary target for horizontal wellbore landing and hydraulic fracturing because of its better rock properties. Even with this new technology, the primary recovery factor is believed to be only around 10%. This study is to evaluate various gas injection EOR methods to try to improve on that low recovery factor of 10%. In this study, the Elm Coulee Oil Field in the Williston Basin was selected as the area of interest. Static reservoir models featuring the rock property heterogeneity of the Middle Bakken Member were built, and fluid property models were built based on Bakken reservoir fluid sample PVT data. By employing both compositional model simulation and Todd-Longstaff solvent model simulation methods, miscible gas injections were simulated and the simulations speculated that oil recovery increased by 10% to 20% of OOIP in 30 years. The compositional simulations yielded lower oil recovery compared to the solvent model simulations. Compared to the homogeneous model, the reservoir model featuring rock property heterogeneity in the vertical direction resulted in slightly better oil recovery, but with earlier CO2 break-through and larger CO2 production, suggesting that rock property heterogeneity is an important property for modeling because it has a big effect on the simulation results. Long hydraulic fractures shortened CO2 break-through time greatly and increased CO 2 production. Water-alternating-gas injection schemes and injection-alternating-shut-in schemes can provide more options for gas injection EOR projects, especially for gas production management. Compared to CO2 injection, separator gas injection yielded slightly better oil recovery, meaning separator gas could be a good candidate for gas injection EOR; lean gas generated the worst results. Reservoir simulations also indicate that original rock properties are the dominant factor for the ultimate oil recovery for both primary recovery and gas injection EOR. Because reservoir simulations provide critical inputs for project planning and management, more effort needs to be invested into reservoir modeling and simulation, including building enhanced geologic models, fracture characterization and modeling, and history matching with field data. Gas injection EOR projects are integrated projects, and the viability of a project also depends on different economic conditions.

  9. Comparison Between the Two-Injection Technique and the Four-Injection Technique in Axillary Brachial Plexus Block with Articaine.

    PubMed

    Ertikin, Aysun; Argun, Güldeniz; Mısırlıoğlu, Mesut; Aydın, Murat; Arıkan, Murat; Kadıoğulları, Nihal

    2017-10-01

    In this study, we aimed to compare axillary brachial plexus block using the two-injection and four-injection techniques assisted with ultrasonography (USG) and nerve stimulator in patients operated for carpal tunnel syndrome with articaine. To evaluate which technique is more effective, we compared the onset time, effectiveness, and duration of block procedures, patient satisfaction, adverse effect of the drug, and complication rates of the motor and sensory blocks. Sixty patients were randomly divided into two groups. A mixture of physiologic serum added to articain with NaHCO 3 (30 mL) was injected into the patients' axilla in both the groups. After the blockage of the musculocutaneous nerve in both the groups, the median nerve in the two-injection group and the median nerve, ulnar nerve, and radial nerve in the four-injection group were blocked. In brachial plexus nerves, sensorial blockage was evaluated with pinprick test, and motor block was evaluated by contraction of the muscles innervated by each nerve. The adverse effects and complications, visual analog scale (VAS) values during the operation, and post-operative patient satisfaction were recorded. Sufficient analgesia and anaesthesia were achieved with no need for an additional local anaesthetics in both the groups. Furthermore, additional sedation requirements were found to be similar in both the groups. A faster rate and a more effective complete block were achieved in more patients from the four-injection group. In the two-injection group, the block could not be achieved for N. radialis in one patient. All other nerves were successfully blocked. Whereas the blockage procedure lasted longer in the four-injection group, the VAS values recorded during the blockage procedure were higher in the four-injection group. No statistical difference was found with regard to patient satisfaction, and no adverse effects and complications were observed in any group. Although the multi-injection method takes more time, it provides faster anaesthesia and more complete blockage than the two-injection method used with articain. The two-injection method can also be used in specific surgery such as for carpal tunnel syndrome, as an alternative to multi-injection method.

  10. TH-EF-207A-04: A Dynamic Contrast Enhanced Cone Beam CT Technique for Evaluation of Renal Functions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Z; Shi, J; Yang, Y

    Purpose: To develop a simple but robust method for the early detection and evaluation of renal functions using dynamic contrast enhanced cone beam CT technique. Methods: Experiments were performed on an integrated imaging and radiation research platform developed by our lab. Animals (n=3) were anesthetized with 20uL Ketamine/Xylazine cocktail, and then received 200uL injection of iodinated contrast agent Iopamidol via tail vein. Cone beam CT was acquired following contrast injection once per minute and up to 25 minutes. The cone beam CT was reconstructed with a dimension of 300×300×800 voxels of 130×130×130um voxel resolution. The middle kidney slices in themore » transvers and coronal planes were selected for image analysis. A double exponential function was used to fit the contrast enhanced signal intensity versus the time after contrast injection. Both pixel-based and region of interest (ROI)-based curve fitting were performed. Four parameters obtained from the curve fitting, namely the amplitude and flow constant for both contrast wash in and wash out phases, were investigated for further analysis. Results: Robust curve fitting was demonstrated for both pixel based (with R{sup 2}>0.8 for >85% pixels within the kidney contour) and ROI based (R{sup 2}>0.9 for all regions) analysis. Three different functional regions: renal pelvis, medulla and cortex, were clearly differentiated in the functional parameter map in the pixel based analysis. ROI based analysis showed the half-life T1/2 for contrast wash in and wash out phases were 0.98±0.15 and 17.04±7.16, 0.63±0.07 and 17.88±4.51, and 1.48±0.40 and 10.79±3.88 minutes for the renal pelvis, medulla and cortex, respectively. Conclusion: A robust method based on dynamic contrast enhanced cone beam CT and double exponential curve fitting has been developed to analyze the renal functions for different functional regions. Future study will be performed to investigate the sensitivity of this technique in the detection of radiation induced kidney dysfunction.« less

  11. Two global data sets of daily fire emission injection heights since 2003

    NASA Astrophysics Data System (ADS)

    Rémy, Samuel; Veira, Andreas; Paugam, Ronan; Sofiev, Mikhail; Kaiser, Johannes W.; Marenco, Franco; Burton, Sharon P.; Benedetti, Angela; Engelen, Richard J.; Ferrare, Richard; Hair, Jonathan W.

    2017-02-01

    The Global Fire Assimilation System (GFAS) assimilates fire radiative power (FRP) observations from satellite-based sensors to produce daily estimates of biomass burning emissions. It has been extended to include information about injection heights derived from fire observations and meteorological information from the operational weather forecasts of ECMWF. Injection heights are provided by two distinct methods: the Integrated Monitoring and Modelling System for wildland fires (IS4FIRES) parameterisation and the one-dimensional plume rise model (PRM). A global database of daily biomass burning emissions and injection heights at 0.1° resolution has been produced for 2003-2015 and is continuously extended in near-real time with the operational GFAS service of the Copernicus Atmospheric Monitoring Service (CAMS). In this study, the two injection height data sets were compared with the new MPHP2 (MISR Plume Height Project 2) satellite-based plume height retrievals. The IS4FIRES parameterisation showed a better overall agreement than the observations, while the PRM was better at capturing the variability of injection heights. The performance of both parameterisations is also dependent on the type of vegetation. Furthermore, the use of biomass burning emission heights from GFAS in atmospheric composition forecasts was assessed in two case studies: the South AMerican Biomass Burning Analysis (SAMBBA) campaign which took place in September 2012 in Brazil, and a series of large fire events in the western USA in August 2013. For these case studies, forecasts of biomass burning aerosol species by the Composition Integrated Forecasting System (C-IFS) of CAMS were found to better reproduce the observed vertical distribution when using PRM injection heights from GFAS compared to aerosols emissions being prescribed at the surface. The globally available GFAS injection heights introduced and evaluated in this study provide a comprehensive data set for future fire and atmospheric composition modelling studies.

  12. Determination of Total Selenium in Infant Formulas: Comparison of the Performance of FIA and MCFA Flow Systems

    PubMed Central

    Pistón, Mariela; Knochen, Moisés

    2012-01-01

    Two flow methods, based, respectively, on flow-injection analysis (FIA) and on multicommutated flow analysis (MCFA), were compared with regard to their use for the determination of total selenium in infant formulas by hydride-generation atomic absorption spectrometry. The method based on multicommutation provided lower detection and quantification limits (0.08 and 0.27 μg L−1 compared to 0.59 and 1.95 μ L−1, resp.), higher sampling frequency (160 versus. 70 samples per hour), and reduced reagent consumption. Linearity, precision, and accuracy were similar for the two methods compared. It was concluded that, while both methods proved to be appropriate for the purpose, the MCFA-based method exhibited a better performance. PMID:22505923

  13. Evaluation of the foetal time to death in mice after application of direct and indirect euthanasia methods.

    PubMed

    Muñoz-Mediavilla, C; Cámara, J A; Salazar, S; Segui, B; Sanguino, D; Mulero, F; de la Cueva, E; Blanco, I

    2016-04-01

    Directive 2010/63/EU on the protection of animals used for scientific purposes requires that the killing of mammal foetuses during the last third of their gestational period should be accomplished through effective and humane methods. The fact that murine foetuses are resistant to hypoxia-mediated euthanasia renders the current euthanasia methods ineffective or humane for the foetuses when these methods are applied to pregnant female mice. We have assessed the time to death of foetuses after performing either indirect (dam euthanasia) or direct (via intraplacental injection--a new approach to euthanasia) euthanasia methods in order to determine a euthanasia method that is appropriate, ethical and efficient for the killing of mouse foetuses. The respective times to death of foetuses after performing the three most commonly used euthanasia methods (namely cervical dislocation, CO2inhalation and intraperitoneal sodium pentobarbital administration) were recorded. Absence of foetal heartbeat was monitored via ultrasound. We consider that the most effective and humane method of foetal euthanasia was the one able to achieve foetal death within the shortest possible period of time. Among the indirect euthanasia methods assessed, the administration of a sodium pentobarbital overdose to pregnant female mice was found to be the fastest for foetuses, with an average post-treatment foetal death of approximately 29.8 min. As for the direct euthanasia method assessed, foetal time to death after intraplacental injection of sodium pentobarbital was approximately 14 min. Significant differences among the different mouse strains employed were found. Based on the results obtained in our study, we consider that the administration of a sodium pentobarbital overdose by intraplacental injection to be an effective euthanasia method for murine foetuses. © The Author(s) 2015.

  14. Patellar Tendinopathy

    PubMed Central

    Schwartz, Aaron; Watson, Jonathan N.; Hutchinson, Mark R.

    2015-01-01

    Context: Patellar tendinopathy is a common condition. There are a wide variety of treatment options available, the majority of which are nonoperative. No consensus exists on the optimal method of treatment. Evidence Acquisition: PubMed spanning 1962-2014. Study Design: Clinical review. Level of Evidence: Level 4. Results: The majority of cases resolve with nonoperative therapy: rest, physical therapy with eccentric exercises, cryotherapy, anti-inflammatories, corticosteroid injections, extracorporeal shockwave therapy, glyceryl trinitrate, platelet-rich plasma injections, and ultrasound-guided sclerosis. Refractory cases may require either open or arthroscopic debridement of the patellar tendon. Corticosteroid injections provide short-term pain relief but increase risk of tendon rupture. Anti-inflammatories and injectable agents have shown mixed results. Surgical treatment is effective in many refractory cases unresponsive to nonoperative modalities. Conclusion: Physical therapy with an eccentric exercise program is the mainstay of treatment for patellar tendinopathy. Platelet-rich plasma has demonstrated mixed results; evidence-based recommendations on its efficacy cannot be made. In the event that nonoperative treatment fails, surgical intervention has produced good to excellent outcomes in the majority of patients. PMID:26502416

  15. Bias Dependence of the Electrical Spin Injection into GaAs from Co -Fe -B /MgO Injectors with Different MgO Growth Processes

    NASA Astrophysics Data System (ADS)

    Barate, P.; Liang, S. H.; Zhang, T. T.; Frougier, J.; Xu, B.; Schieffer, P.; Vidal, M.; Jaffrès, H.; Lépine, B.; Tricot, S.; Cadiz, F.; Garandel, T.; George, J. M.; Amand, T.; Devaux, X.; Hehn, M.; Mangin, S.; Tao, B.; Han, X. F.; Wang, Z. G.; Marie, X.; Lu, Y.; Renucci, P.

    2017-11-01

    We investigate the influence of the MgO growth process on the bias dependence of the electrical spin injection from a Co -Fe -B /MgO spin injector into a GaAs-based light-emitting diode (spin LED). With this aim, textured MgO tunnel barriers are fabricated either by sputtering or molecular-beam-epitaxy (MBE) methods. For the given growth parameters used for the two techniques, we observe that the circular polarization of the electroluminescence emitted by spin LEDs is rather stable as a function of the injected current or applied bias for the samples with sputtered tunnel barriers, whereas the corresponding circular polarization decreases abruptly for tunnel barriers grown by MBE. We attribute these different behaviors to the different kinetic energies of the injected carriers linked to differing amplitudes of the parasitic hole current flowing from GaAs to Co-Fe-B in both cases.

  16. Pharmacokinetics and Bioavailability of the GnRH Analogs in the Form of Solution and Zn2+-Suspension After Single Subcutaneous Injection in Female Rats.

    PubMed

    Suszka-Świtek, Aleksandra; Ryszka, Florian; Dolińska, Barbara; Dec, Renata; Danch, Alojzy; Filipczyk, Łukasz; Wiaderkiewicz, Ryszard

    2017-04-01

    Although many synthetic gonadoliberin analogs have been developed, only a few of them, including buserelin, were introduced into clinical practice. Dalarelin, which differs from buserelin by just one aminoacid in the position 6 (D-Ala), is not widely used so far. Gonadotropin-releasing hormone (GnRH) analogs are used to treat many different illnesses and are available in different forms like solution for injection, nasal spray, microspheres, etc. Unfortunately, none of the above drug formulations can release the hormones for 24 h. We assumed that classical suspension could solve this problem. Two sets of experiments were performed. In the first one, buserelin and dalarelin were injected into mature female rats in two forms: suspension, in which the analogs are bounded by Zn 2+ ions and solution. The pharmacokinetic parameters and bioavailability of the analogs were calculated, based on their concentration in the plasma measured by high-performance liquid chromatography method (HPLC). In the second experiment, the hormones in two different forms were injected into superovulated immature female rats and then the concentration of Luteinizing hormone (LH), Follicle-stimulating hormone (FSH) and 17β-estradiol in the serum was measured by radioimmunological method. The Extent of Biological Availability (EBA), calculated on the base of AUC 0-∞ , showed that in the form of solution buserelin and dalarelin display, respectively, only 13 and 8 % of biological availability of their suspension counterparts. Comparing both analogs, the EBA of dalarelin was half (53 %) that of buserelin delivered in the form of solution and 83 % when they were delivered in the form of suspension. The injection of buserelin or dalarelin, in the form of solution or suspension, into superovulated female rats increased LH, FSH and estradiol concentration in the serum. However, after injection of the analogs in the form of suspension, the high concentration of LH and FSH in the serum persisted longer. Performed studies indicate that GnRH analogs in the form of suspension have higher bioavailability than their solution counterparts. It influences the effects of their action, especially in relation to LH and FSH.

  17. Caprock Integrity during Hydrocarbon Production and CO2 Injection in the Goldeneye Reservoir

    NASA Astrophysics Data System (ADS)

    Salimzadeh, Saeed; Paluszny, Adriana; Zimmerman, Robert

    2016-04-01

    Carbon Capture and Storage (CCS) is a key technology for addressing climate change and maintaining security of energy supplies, while potentially offering important economic benefits. UK offshore, depleted hydrocarbon reservoirs have the potential capacity to store significant quantities of carbon dioxide, produced during power generation from fossil fuels. The Goldeneye depleted gas condensate field, located offshore in the UK North Sea at a depth of ~ 2600 m, is a candidate for the storage of at least 10 million tons of CO2. In this research, a fully coupled, full-scale model (50×20×8 km), based on the Goldeneye reservoir, is built and used for hydro-carbon production and CO2 injection simulations. The model accounts for fluid flow, heat transfer, and deformation of the fractured reservoir. Flow through fractures is defined as two-dimensional laminar flow within the three-dimensional poroelastic medium. The local thermal non-equilibrium between injected CO2 and host reservoir has been considered with convective (conduction and advection) heat transfer. The numerical model has been developed using standard finite element method with Galerkin spatial discretisation, and finite difference temporal discretisation. The geomechanical model has been implemented into the object-oriented Imperial College Geomechanics Toolkit, in close interaction with the Complex Systems Modelling Platform (CSMP), and validated with several benchmark examples. Fifteen major faults are mapped from the Goldeneye field into the model. Modal stress intensity factors, for the three modes of fracture opening during hydrocarbon production and CO2 injection phases, are computed at the tips of the faults by computing the I-Integral over a virtual disk. Contact stresses -normal and shear- on the fault surfaces are iteratively computed using a gap-based augmented Lagrangian-Uzawa method. Results show fault activation during the production phase that may affect the fault's hydraulic conductivity and its connection to the reservoir rocks. The direction of growth is downward during production and it is expected to be upward during injection. Elevated fluid pressures inside faults during CO2 injection may further facilitate fault activation by reducing normal effective stresses. Activated faults can act as permeable conduits and potentially jeopardise caprock integrity for CO2 storage purposes.

  18. Enhanced oil recovery by nitrogen and carbon dioxide injection followed by low salinity water flooding for tight carbonate reservoir: experimental approach

    NASA Astrophysics Data System (ADS)

    Georges Lwisa, Essa; Abdulkhalek, Ashrakat R.

    2018-03-01

    Enhanced Oil Recovery techniques are one of the top priorities of technology development in petroleum industries nowadays due to the increase in demand for oil and gas which cannot be equalized by the primary production or secondary production methods. The main function of EOR process is to displace oil to the production wells by the injection of different fluids to supplement the natural energy present in the reservoir. Moreover, these injecting fluids can also help in the alterations of the properties of the reservoir like lowering the IFTs, wettability alteration, a change in pH value, emulsion formation, clay migration and oil viscosity reduction. The objective of this experiment is to investigate the residual oil recovery by combining the effects of gas injection followed by low salinity water injection for low permeability reservoirs. This is done by a series of flooding tests on selected tight carbonate core samples taken from Zakuum oil field in Abu Dhabi by using firstly low salinity water as the base case and nitrogen & CO2injection followed by low salinity water flooding at reservoir conditions of pressure and temperature. The experimental results revealed that a significant improvement of the oil recovery is achieved by the nitrogen injection followed by the low salinity water flooding with a recovery factor of approximately 24% of the residual oil.

  19. Re-injection feasibility study of fracturing flow-back fluid in shale gas mining

    NASA Astrophysics Data System (ADS)

    Kang, Dingyu; Xue, Chen; Chen, Xinjian; Du, Jiajia; Shi, Shengwei; Qu, Chengtun; Yu, Tao

    2018-02-01

    Fracturing flow-back fluid in shale gas mining is usually treated by re-injecting into formation. After treatment, the fracturing flow-back fluid is injected back into the formation. In order to ensure that it will not cause too much damage to the bottom layer, feasibility evaluations of re-injection of two kinds of fracturing fluid with different salinity were researched. The experimental research of the compatibility of mixed water samples based on the static simulation method was conducted. Through the analysis of ion concentration, the amount of scale buildup and clay swelling rate, the feasibility of re-injection of different fracturing fluid were studied. The result shows that the swelling of the clay expansion rate of treated fracturing fluid is lower than the mixed water of treated fracturing fluid and the distilled water, indicating that in terms of clay expansion rate, the treated fracturing flow-back fluid is better than that of water injection after re-injection. In the compatibility test, the maximum amount of fouling in the Yangzhou oilfield is 12mg/L, and the maximum value of calcium loss rate is 1.47%, indicating that the compatibility is good. For the fracturing fluid with high salinity in the Yanchang oilfield, the maximum amount of scaling is 72mg/L, and the maximum calcium loss rate is 3.50%, indicating that the compatibility is better.

  20. Chemical Analysis through CL-Detection Assisted by Periodate Oxidation

    PubMed Central

    Evmiridis, Nicholaos P.; Vlessidis, Athanasios G.; Thanasoulias, Nicholas C.

    2007-01-01

    The progress of the research work of the author and his colleagues on the field of CL-emission generated by pyrogallol oxidation and further application for the direct determination of periodate and indirect or direct determination of other compounds through flow-injection manifold/CL-detection set up is described. The instrumentation used for these studies was a simple flow-injection manifold that provides good reproducibility, coupled to a red sensitive photomultiplier that gives sensitive CL-detection. In addition, recent reports on studies and analytical methods based on CL-emission generated by periodate oxidation by other authors are included. PMID:17611611

  1. Office-based laryngeal injection of botulinum toxin for paradoxical vocal fold motion in a child.

    PubMed

    Montojo, José; González, Ramón; Hernández, Estefanía; Zafra, Miguel; Plaza, Guillermo

    2015-07-01

    We describe the case of a 13-year-old girl with paradoxical vocal fold motion (PVFM) who failed to improve with repeated medical treatment, speech therapy and psychotherapy, but was successfully treated with botulinum toxin A (BTX-A) injection to the vocal folds. For delivering the BTX-A we used a channeled fiber-optic laryngoscope under local anesthesia, in an office setting. The patient remained asymptomatic of PVFM for 5 months, was successfully treated again with the same method, and had no important side effects. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Comparative Performance of Engines Using a Carburetor, Manifold Injection, and Cylinder Injection

    NASA Technical Reports Server (NTRS)

    Schey, Oscar W; Clark, J Denny

    1939-01-01

    The comparative performance was determined of engines using three methods of mixing the fuel and the air: the use of a carburetor, manifold injection, and cylinder injection. The tests were made of a single-cylinder engine with a Wright 1820-G air-cooled cylinder. Each method of mixing the fuel and the air was investigated over a range of fuel-air ratios from 0.10 to the limit of stable operation and at engine speeds of 1,500 and 1,900 r.p.m. The comparative performance with a fuel-air ratio of 0.08 was investigated for speeds from 1,300 to 1,900 r.p.m. The results show that the power obtained with each method closely followed the volumetric efficiency; the power was therefore the highest with cylinder injection because this method had less manifold restriction. The values of minimum specific fuel consumption obtained with each method of mixing of fuel and air were the same. For the same engine and cooling conditions, the cylinder temperatures are the same regardless of the method used for mixing the fuel and the air.

  3. Flow injection spectrophotometric method for chloride determination in natural waters using Hg(SCN)(2) immobilized in epoxy resin.

    PubMed

    Silva, Claudineia R; Vieira, Heberth J; Canaes, Larissa S; Nóbrega, Joaquim A; Fatibello-Filho, Orlando

    2005-02-28

    A flow injection (FI) spectrophotometric method was proposed for the determination of chloride ion in natural waters. The determination of chloride was carried out by reaction with Hg(SCN)(2) immobilized in an epoxy resin bead in a solid-phase reactor (SPR) and the thiocyanate ions released were determined spectrophotometrically at 480nm after complexing reaction with Fe(III). The analytical curve for chloride was linear in the concentration range from 5.6 x 10(-5) to 2.2 x 10(-4)moll(-1) with a detection limit of 1.4 x 10(-5)moll(-1). The relative standard deviation (R.S.D.) was 2.2% for a solution containing 2.2 x 10(-4)moll(-1) (n = 10). The simple manifold allows a routine analytical frequency of 100 determinations per hour. The main advantage of the developed method is the 400% reduction of the Hg waste solution generated when compared to conventional methods for chloride determination based on the same spectrophotometric reaction.

  4. A novel flow injection spectrophotometric method using plant extracts as green reagent for the determination of doxycycline

    NASA Astrophysics Data System (ADS)

    Palamy, Sysay; Ruengsitagoon, Wirat

    2017-01-01

    A novel flow injection spectrophotometric method was developed for the determination of doxycycline in pharmaceutical preparations using iron(III) contained in extracts from plants. The assay was based on the complex formed between doxycycline and iron(III) characterized by an absorption maximum at 435 nm. The calibration graphs obtained over the doxycycline concentration range 5-250 μg mL- 1 gave correlation coefficients of 0.9979, 0.9987 and 0.9987 with the three green reagents prepared from Senna alata (L.) Roxb. (S. alata), Polygonum hydropiper L. (P. hydropiper) or Diplazium esculentum (Retz.) Sw. (D. esculentum), respectively. The relative standard deviations of the repeatability was < 2.00%. The percentage recoveries were in the range of 98.27-101.03%. Doxycycline contents obtained by this new method and by the reference methods reported in literature were in agreement at 95% confidence level with the paired t-test. The sample throughput was 36 h- 1 for each green reagent.

  5. Creating fluid injectivity in tar sands formations

    DOEpatents

    Stegemeier, George Leo; Beer, Gary Lee; Zhang, Etuan

    2012-06-05

    Methods for treating a tar sands formation are described herein. Methods for treating a tar sands may include heating a portion of a hydrocarbon layer in the formation from one or more heaters located in the portion. The heat may be controlled to increase the permeability of at least part of the portion to create an injection zone in the portion with an average permeability sufficient to allow injection of a fluid through the injection zone. A drive fluid and/or an oxidizing fluid may be provided into the injection zone. At least some hydrocarbons including mobilized hydrocarbons are produced from the portion.

  6. Creating fluid injectivity in tar sands formations

    DOEpatents

    Stegemeier, George Leo; Beer, Gary Lee; Zhang, Etuan

    2010-06-08

    Methods for treating a tar sands formation are described herein. Methods for treating a tar sands may include heating a portion of a hydrocarbon layer in the formation from one or more heaters located in the portion. The heat may be controlled to increase the permeability of at least part of the portion to create an injection zone in the portion with an average permeability sufficient to allow injection of a fluid through the injection zone. A drive fluid and/or an oxidizing fluid may be provided into the injection zone. At least some hydrocarbons are produced from the portion.

  7. Injection of demineralized bone matrix with bone marrow concentrate improves healing in unicameral bone cyst.

    PubMed

    Di Bella, Claudia; Dozza, Barbara; Frisoni, Tommaso; Cevolani, Luca; Donati, Davide

    2010-11-01

    Unicameral bone cysts are benign lesions that usually spontaneously regress with skeletal maturity; however, the high risk of pathologic fractures often justifies treatment that could reinforce a weakened bone cortex. Various treatments have been proposed but there is no consensus regarding the best procedure. We compared the healing rates and failures of two methods of cure based on multiple injections of corticosteroid or a single injection of demineralized bone matrix (DBM) in association with bone marrow concentrate (BMC). We retrospectively reviewed 184 patients who had one of the two treatments for unicameral bone cysts with cortical erosion. Clinical records were reviewed for treatment failures and radiographs for healing in all patients. The minimum followup was 12 months for the Steroids Group (mean, 48 months; range, 12-120 months) and 12 months for the DBM + BMC Group (mean, 20 months; range, 12-28 months). After one treatment we observed a lower healing rate of cysts treated with multiple injections of steroids compared with the healing after the first injection of DBM + BMC (21% versus 58%, respectively). At last followup, 38% healed with steroids and 71% with DBM + BMC. The rate of failure after one steroid injection was higher than after a single injection of BDM + BMC (63% versus 24%, respectively). We observed no difference in fracture rates after treatment between the two groups. A single injection of DBM added with autologous bone marrow concentrate appears to provide a higher healing rate with a lower number of failures compared with a single injection of steroids.

  8. Evidence based knee injections for the management of arthritis

    PubMed Central

    Cheng, Olivia T.; Souzdalnitski, Dmitri; Vrooman, Bruce; Cheng, Jianguo

    2012-01-01

    Objective Arthritis of the knee affects 46 million Americans. We aimed to determine the level of evidence of intraarticular knee injections in the management of arthritic knee pain. Methods We systematically searched PUBMED/MEDLINE and the Cochrane databases for articles published on knee injections and evaluated their level of evidence and recommendations according to established criteria. Results The evidence supports the use of intraarticular corticosteroid injections for rheumatoid arthritis (1A+ level), osteoarthritis (1A+ level), and juvenile idiopathic arthritis (2C+ level). Pain relief and functional improvement are significant for months up to one year after the injection. Triamcinolone hexacetonide offers an advantage over triamcinolone acetonide and should be the intraarticular steroid of choice (2B+ level). Intraarticular injection of hyaluronate may provide longer pain relief than steroid injection in osteoarthritis (2B+ level). It can also be effective for rheumatoid arthritis knee pain (1A+ level). However, it is only recommended for patients with significant surgical risk factors and for patients with mild radiographic disease in whom conservative treatment has failed (2B± level). Botulinum toxin Type A injection is effective in reducing arthritic knee pain (2B+ level) and so is tropisetron (2B+ level) and tanezumab (2B+ level). The new agents, such as rAAV2-TNFR:Fc, SB-210396/CE 9.1, and various radioisotopes have provided various degrees of success, but their long-term safety and efficacy remains to be determined. Conclusions We conclude that strong evidence supports the use of intraarticular knee injection as a valuable intervention in the continuum of management of arthritis between conservative treatment and knee surgeries. PMID:22621287

  9. A comparison of implantation methods for large PIT tags or injectable acoustic transmitters in juvenile Chinook salmon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, Katrina V.; Brown, Richard S.; Deng, Zhiqun

    The miniaturization of acoustic transmitters may allow greater flexibility in terms of the size and species of fish available to tag. New downsized injectable acoustic tags similar in shape to passive integrated transponder tags can be rapidly injected rather than surgically implanted through a sutured incision, as is current practice. Before wide-scale field use of these injectable transmitters, standard protocols to ensure the most effective and least damaging methods of implantation must be developed. Three implantation methods were tested in various sizes of juvenile Chinook salmon Oncorhynchus tschawytscha. Methods included a needle bevel-down injection, a needle bevel-up injection with amore » 90-degree rotation, and tag implantation through an unsutured incision. Tagged fish were compared to untagged control groups. Weight and wound area were measured at tagging and every week for 3 weeks; holding tanks were checked daily for mortalities and tag losses. No differences among treatments were found in growth, tag loss, or survival, but wound area was significantly reduced among incision-treated fish. The bevel-up injection had the worst results in terms of tag loss and wound area and also had high mortality. Implantation through an incision resulted in the lowest tag loss but the highest mortality. Fish from the bevel-down treatment group had the least mortality; wound areas also were smaller than the bevel-up treatment group. Cumulatively, the data suggest that the unsutured incision and bevel-down injection methods were the most effective; the drawbacks of both methods are described in detail. However, we further recommend larger and longer studies to find more robust thresholds for tagging size that include more sensitive measures.« less

  10. Effect of exosome isolation methods on physicochemical properties of exosomes and clearance of exosomes from the blood circulation.

    PubMed

    Yamashita, Takuma; Takahashi, Yuki; Nishikawa, Makiya; Takakura, Yoshinobu

    2016-01-01

    Exosomes, which are expected to be delivery systems for biomolecules such as nucleic acids, are collected by several methods. However, the effect of exosome isolation methods on the characteristics of exosomes as drug carriers, such as recovery efficiency after sterile filtration and pharmacokinetics, has not been investigated despite the importance of these characteristics for the development of exosome-based delivery systems. In the present study, exosomes collected from murine melanoma B16-BL6 cells by several methods were compared with respect to dispersibility, recovery rate after filtering, and clearance from the blood circulation in mice. The exosomes were collected by three ultracentrifugation-based methods: simple ultracentrifugation/pelleting (pelleting method), ultracentrifugation with an iodixanol cushion (cushion method), and ultracentrifugation on an iodixanol density gradient (gradient method). The isolation methods had little effect on the particle number of exosomes. In contrast, transmission electron microscopy observation and size distribution measurement using tunable resistive pulse sensing indicated that the exosomes of the gradient method were more dispersed than the others. The exosomes were labeled with Gaussia luciferase and intravenously injected into mice. Clearance of injected exosomes from the blood circulation did not significantly change with isolation methods. When the exosomes were filtered using a 0.2-μm filter, the recovery rate was 82% for the exosomes of the gradient method, whereas it was less than 50% for the others. These results indicate that the exosome isolation method markedly affects the dispersibility and filtration efficiency of the exosomes. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Measurement of Droplet Sizes by the Diffraction Ring Method

    DTIC Science & Technology

    1948-07-27

    for measuring the droplet size distribution in sprays ob- tained by pressure injection of a liquid through an orifice «roby air- stream atomization...Diameter vs Injection Pressure 10 6. Distribution Curves for Spray Sample of Water Injected into Air Stream .... 11 Page ii Page Hi i^ujJa-je jii...tion in sprays obtained by pressure injection of a liquid through an orifice or by air- stream atomization. Perhaps the most widely used method

  12. A Cooperative Approach to Virtual Machine Based Fault Injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Naughton III, Thomas J; Engelmann, Christian; Vallee, Geoffroy R

    Resilience investigations often employ fault injection (FI) tools to study the effects of simulated errors on a target system. It is important to keep the target system under test (SUT) isolated from the controlling environment in order to maintain control of the experiement. Virtual machines (VMs) have been used to aid these investigations due to the strong isolation properties of system-level virtualization. A key challenge in fault injection tools is to gain proper insight and context about the SUT. In VM-based FI tools, this challenge of target con- text is increased due to the separation between host and guest (VM).more » We discuss an approach to VM-based FI that leverages virtual machine introspection (VMI) methods to gain insight into the target s context running within the VM. The key to this environment is the ability to provide basic information to the FI system that can be used to create a map of the target environment. We describe a proof- of-concept implementation and a demonstration of its use to introduce simulated soft errors into an iterative solver benchmark running in user-space of a guest VM.« less

  13. Induction of Contraception by Intraepididymal Sclerotherapy

    PubMed Central

    Park, Hyoung Keun; Paick, Sung Hyun; Kim, Hyeong Gon; Lho, Yong Soo

    2014-01-01

    Purpose The objective of the present study was to evaluate the efficacy of a sclerosing solution for inducing epididymal occlusion in male rats. Materials and Methods Male Sprague-Dawley rats were divided into two groups: an injection group (n=20) and control group (n=20). Before injecting the sclerosing agent, seminal vesiculectomy and sperm identification using electrostimulation were performed in all of the rats. In the injection group, 0.2 mL of 0.1% sodium tetradecyl sulfate solution was injected into the epididymis. In the sham group, only the identification of the epididymis was performed. At 4 and 12 weeks after the injection, semen was collected by electrostimulation and evaluated to assess the contraceptive effect. Epididymis was evaluated by hematoxylin and eosin (H&E) staining. Results After 4 and 12 weeks, semen collection was performed in the two groups. Sperms were not observed in the injection group, while there was no change in the sperms in the sham group. H&E staining showed the obstruction of epididymal tubules and an accumulation of inflammatory cells in the injection group. Conclusions This study showed that the sclerosing agent induced sterilization in male rats. This result suggests that the injection method can replace vasectomy as a contraceptive method. However, a further study of large animals and a clinical study are needed. Further, the long-term effectiveness of this method needs to be studied. PMID:25237657

  14. Understanding and meeting injection device needs in multiple sclerosis: a survey of patient attitudes and practices

    PubMed Central

    Verdun di Cantogno, Elisabetta; Russell, Susan; Snow, Tom

    2011-01-01

    Background: All established disease-modifying drugs for multiple sclerosis require parenteral administration, which can cause difficulties for some patients, sometimes leading to suboptimal adherence. A new electronic autoinjection device has been designed to address these issues. Methods: Patients with relapsing multiple sclerosis currently receiving subcutaneous or intramuscular interferon beta-1a, interferon beta-1b, or glatiramer acetate completed an online questionnaire (July 4–25, 2008) that surveyed current injection practices, experiences with current injection methods, and impressions and appeal of the new device. Results: In total, 422 patients completed the survey, of whom 44% used autoinjectors, 43% prefilled syringes, and 13% syringes and vials; overall, 66% currently self-injected. Physical and psychological barriers to self-injection included difficulty with injections, needle phobia, and concerns over correct injection technique. Only 40% of respondents were “very satisfied” with their current injection method. The new electronic autoinjector was rated as “very appealing” by 65% of patients. The benefits of the new device included the ability to customize injection settings and to review dosing history. Conclusion: New technologies may help patients overcome physical and psychological barriers to self-injection. The combination of a reliable and flexible autoinjection device with dose-monitoring technology may improve communication between health care professionals and patients, and improve treatment adherence. PMID:21573048

  15. Electropolymerized fluorinated aniline-based fiber for headspace solid-phase microextraction and gas chromatographic determination of benzaldehyde in injectable pharmaceutical formulations.

    PubMed

    Mohammadi, Ali; Mohammadi, Somayeh; Bayandori Moghaddam, Abdolmajid; Masoumi, Vahideh; Walker, Roderick B

    2014-10-01

    In this study, a simple method was developed and validated to detect trace levels of benzaldehyde in injectable pharmaceutical formulations by solid-phase microextraction coupled with gas chromatography-flame ionization detector. Polyaniline was electrodeposited on a platinum wire in trifluoroacetic acid solvent by cyclic voltammetry technique. This fiber shows high thermal and mechanical stability and high performance in extraction of benzaldehyde. Extraction and desorption time and temperature, salt effect and gas chromatography parameters were optimized as key parameters. At the optimum conditions, the fiber shows good linearity between peak area ratio of benzaldehyde/3-chlorobenzaldehyde and benzaldehyde concentration in the range of 50-800 ng/mL with percent relative standard deviation values ranging from 0.75 to 8.64% (n = 3). The limits of quantitation and detection were 50 and 16 ng/mL, respectively. The method has the requisite selectivity, sensitivity, accuracy and precision to assay benzaldehyde in injectable pharmaceutical dosage forms. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Sensitive flow-injection spectrophotometric analysis of bromopride.

    PubMed

    Lima, Liliane Spazzapam; Los Weinert, Patrícia; Pezza, Leonardo; Pezza, Helena Redigolo

    2014-12-10

    A flow injection spectrophotometric procedure employing merging zones is proposed for direct bromopride determination in pharmaceutical formulations and biological fluids. The proposed method is based on the reaction between bromopride and p-dimethylaminocinnamaldehyde (p-DAC) in acid medium, in the presence of sodium dodecyl sulfate (SDS), resulting in formation of a violet product (λmax=565nm). Experimental design methodologies were used to optimize the experimental conditions. The Beer-Lambert law was obeyed in a bromopride concentration range of 3.63×10(-7) to 2.90×10(-5)molL(-1), with a correlation coefficient (r) of 0.9999. The limits of detection and quantification were 1.07×10(-7) and 3.57×10(-7)molL(-1), respectively. The proposed method was successfully applied to the determination of bromopride in pharmaceuticals and human urine, and recoveries of the drug from these media were in the ranges 99.6-101.2% and 98.6-102.1%, respectively. This new flow injection procedure does not require any sample pretreatment steps. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Using biplanar fluoroscopy to guide radiopaque vascular injections: a new method for vascular imaging.

    PubMed

    O'Brien, Haley D; Williams, Susan H

    2014-01-01

    Studying vascular anatomy, especially in the context of relationships with hard tissues, is of great interest to biologists. Vascular studies have provided significant insight into physiology, function, phylogenetic relationships, and evolutionary patterns. Injection of resin or latex into the vascular system has been a standard technique for decades. There has been a recent surge in popularity of more modern methods, especially radiopaque latex vascular injection followed by CT scanning and digital "dissection." This technique best displays both blood vessels and bone, and allows injections to be performed on cadaveric specimens. Vascular injection is risky, however, because it is not a standardizable technique, as each specimen is variable with regard to injection pressure and timing. Moreover, it is not possible to view the perfusion of injection medium throughout the vascular system of interest. Both data and rare specimens can therefore be lost due to poor or excessive perfusion. Here, we use biplanar video fluoroscopy as a technique to guide craniovascular radiopaque latex injection. Cadaveric domestic pigs (Sus scrofa domestica) and white-tailed deer (Odocoileus virginianus) were injected with radiopaque latex under guidance of fluoroscopy. This method was found to enable adjustments, in real-time, to the rate, location, and pressure at which latex is injected in order to avoid data and specimen loss. In addition to visualizing the injection process, this technique can be used to determine flow patterns, and has facilitated the development of consistent markers for complete perfusion.

  18. Process evaluation of spray injection method for asphalt surface repair

    DOT National Transportation Integrated Search

    1998-12-18

    One method of reducing manpower without cutting production in highway maintenance is to use the spray injection method for asphalt surface repair. Although the benefits of using this method have been well documented by previous research such as the S...

  19. Reservoir Architecture Control on the Geometry of a CO2 Plume Using 4D Seismic, Sleipner Field.

    NASA Astrophysics Data System (ADS)

    Bitrus, Roy; Iacopini, David; Bond, Clare

    2017-04-01

    Time lapse seismic from the Sleipner field, Norwegian North Sea represents a unique database to understand the geometry of a saline aquifer, the Utsira Sand Formation, and its role in containing sequestered CO2. The heterogeneous high permeability Utsira Sand formation bounded by an overlying seal is surrounded by impermeable to semi-permeable intra-reservoir thin shale units that influence the migration of injected CO2. It is important to understand and verify the dynamics of injected CO2 plume migration as this ensures close to accurate predictions of the evolving and stable state of CO2 in storage projects. Previous detailed interpretation results of the thin shale units and permeability flow path chimneys within the Utsira Formation have been used in this research. The Utsira Cap rock, IUTS1 and IUTS1 (Intra-Utsira Shale Units) are the top three units that affect the containment and upward migration path of injected CO2. They are combined with seismic geobodies of the CO2 plume across time lapse data. Here, these seismic geobodies are created using 2 methods to delineate the 3D shape and the cubic volume occupancy of the CO2 plume within the reservoir. Method 1 employs the use of an envelope attribute volume, where samples are extracted from voxels that contain seismic trace amplitude values of injected CO2 across the 3D data. These extracted samples are then tracked throughout the target area and then classed and quantified as a CO2 geobodies. Method 2 applies the same concept; the only difference is the samples extracted from voxels are classed based on the proximity and connectivity of pre-defined amplitude values. Both methods employ the use of a Bayesian classifier which defines the probability density function used to categorise the extracted threshold values. Our result of the 3D geobody shapes are compared against the internal geometry of the reservoir which shows the influence of the cap rock and intra-reservoir thin shales on the CO2 plume acting as baffles and flow paths. The amount of injected CO2 is compared against the occupied volume of CO2 within the reservoir rock. Result values are plotted in graphs and they give an indication of the upper and lower end of reservoir volume occupied by injected supercritical CO2. These values are based on the porosity, permeability, density and temperature values of the rock volume, formation fluid and supercritical CO2. The results also show a decrease in effective rock volume occupied by CO2 reaching the Utsira top cap rock with increase in injected amounts of CO2. Our results indicate that the methods proposed can be applied to storage reservoirs in their early to mid-stages to help predict and understand the internal geometries of the reservoir unit and how they can affect the containment or upward migration flow of CO2. The CO2 volumetric measurement can also be used as a well-grounded assessment for future saline aquifer storage projects.

  20. The Position of Lingula as an Index for Inferior Alveolar Nerve Block Injection in 7-11-Year-Old Children

    PubMed Central

    Ezoddini Ardakani, Fatemeh; Bahrololoumi, Zahra; Zangouie Booshehri, Maryam; Navab Azam, Alireza; Ayatollahi, Fatemeh

    2010-01-01

    Background and aims Inferior alveolar nerve block injection is one of the common intra oral anesthetic techniques, with a failure rate of 15-20%. The aim of this study was to evaluate the position of the lingula as an index for this injection. Materials and methods Thirty eight panoramic radiographs of 7–11 year old patients were analyzed and the distance between the lingula index and occlusal plane was measured. Then, lower alveolar nerve block injection was performed on 88 children. Finally, a visual analogue scale was used to measure the rate of pain in the patients. Results This distance increased with age and in children younger than nine years is −0.45 mm on the right side and −0.95 mm on the left side. This distance in children older than 9 years is −0.23 mm on the right side and 0.47 mm on the left side. The success rates of inferior alveolar nerve block injection based on lingual index were 49% on the right side and 53.8% on the left side. Conclusion As the lingual index has various positions and its distance from the occlusal plane increases with age, it is not an appropriate landmark for inferior alveolar nerve block injection. PMID:22991596

  1. Injectable Anisotropic Nanocomposite Hydrogels Direct in Situ Growth and Alignment of Myotubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De France, Kevin J.; Yager, Kevin G.; Chan, Katelyn J. W.

    Here, while injectable in situ cross-linking hydrogels have attracted increasing attention as minimally invasive tissue scaffolds and controlled delivery systems, their inherently disorganized and isotropic network structure limits their utility in engineering oriented biological tissues. Traditional methods to prepare anisotropic hydrogels are not easily translatable to injectable systems given the need for external equipment to direct anisotropic gel fabrication and/or the required use of temperatures or solvents incompatible with biological systems. Herein, we report a new class of injectable nanocomposite hydrogels based on hydrazone cross-linked poly(oligoethylene glycol methacrylate) and magnetically aligned cellulose nanocrystals (CNCs) capable of encapsulating skeletal muscle myoblastsmore » and promoting their differentiation into highly oriented myotubes in situ. CNC alignment occurs on the same time scale as network gelation and remains fixed after the removal of the magnetic field, enabling concurrent CNC orientation and hydrogel injection. The aligned hydrogels show mechanical and swelling profiles that can be rationally modulated by the degree of CNC alignment and can direct myotube alignment both in two- and three-dimensions following coinjection of the myoblasts with the gel precursor components. As such, these hydrogels represent a critical advancement in anisotropic biomimetic scaffolds that can be generated noninvasively in vivo following simple injection.« less

  2. Injectable Anisotropic Nanocomposite Hydrogels Direct in Situ Growth and Alignment of Myotubes

    DOE PAGES

    De France, Kevin J.; Yager, Kevin G.; Chan, Katelyn J. W.; ...

    2017-09-28

    Here, while injectable in situ cross-linking hydrogels have attracted increasing attention as minimally invasive tissue scaffolds and controlled delivery systems, their inherently disorganized and isotropic network structure limits their utility in engineering oriented biological tissues. Traditional methods to prepare anisotropic hydrogels are not easily translatable to injectable systems given the need for external equipment to direct anisotropic gel fabrication and/or the required use of temperatures or solvents incompatible with biological systems. Herein, we report a new class of injectable nanocomposite hydrogels based on hydrazone cross-linked poly(oligoethylene glycol methacrylate) and magnetically aligned cellulose nanocrystals (CNCs) capable of encapsulating skeletal muscle myoblastsmore » and promoting their differentiation into highly oriented myotubes in situ. CNC alignment occurs on the same time scale as network gelation and remains fixed after the removal of the magnetic field, enabling concurrent CNC orientation and hydrogel injection. The aligned hydrogels show mechanical and swelling profiles that can be rationally modulated by the degree of CNC alignment and can direct myotube alignment both in two- and three-dimensions following coinjection of the myoblasts with the gel precursor components. As such, these hydrogels represent a critical advancement in anisotropic biomimetic scaffolds that can be generated noninvasively in vivo following simple injection.« less

  3. Modeling contrast agent flow in cerebral aneurysms: comparison of CFD with medical imaging

    NASA Astrophysics Data System (ADS)

    Rayz, Vitaliy; Vali, Alireza; Sigovan, Monica; Lawton, Michael; Saloner, David; Boussel, Loic

    2016-11-01

    PURPOSE: The flow in cerebral aneurysms is routinely assessed with X-ray angiography, an imaging technique based on a contrast agent injection. In addition to requiring a patient's catheterization and radiation exposure, the X-ray angiography may inaccurately estimate the flow residence time, as the injection alters the native blood flow patterns. Numerical modeling of the contrast transport based on MRI imaging, provides a non-invasive alternative for the flow diagnostics. METHODS: The flow in 3 cerebral aneurysms was measured in vivo with 4D PC-MRI, which provides time-resolved, 3D velocity field. The measured velocities were used to simulate a contrast agent transport by solving the advection-diffusion equation. In addition, the flow in the same patient-specific geometries was simulated with CFD and the velocities obtained from the Navier-Stokes solution were used to model the transport of a virtual contrast. RESULTS: Contrast filling and washout patterns obtained in simulations based on MRI-measured velocities were in agreement with those obtained using the Navier-Stokes solution. Some discrepancies were observed in comparison to the X-ray angiography data, as numerical modeling of the contrast transport is based on the native blood flow unaffected by the contrast injection. NIH HL115267.

  4. Direct Observation of the Biaxial Stress Effect on Efficiency Droop in GaN-based Light-emitting Diode under Electrical Injection.

    PubMed

    Zheng, Jinjian; Li, Shuiqing; Chou, Chilun; Lin, Wei; Xun, Feilin; Guo, Fei; Zheng, Tongchang; Li, Shuping; Kang, Junyong

    2015-12-04

    Light-emitting diode (LED) efficiency has attracted considerable interest because of the extended use of solid-state lighting. Owing to lack of direct measurement, identification of the reasons for efficiency droop has been restricted. A direct measurement technique is developed in this work for characterization of biaxial stress in GaN-based blue LEDs under electrical injection. The Raman shift of the GaN E2 mode evidently decreases by 4.4 cm(-1) as the driving current on GaN-based LEDs increases to 700 mA. Biaxial compressive stress is released initially and biaxial tensile stress builds up as the current increases with respect to the value of stress-free GaN. First-principles calculations reveal that electron accumulation is responsible for the stress variation in InxGa1-xN/GaN quantum wells, and then reduces the transition probability among quantum levels. This behavior is consistent with the measured current-dependent external quantum efficiency. The rule of biaxial stress-dependent efficiency is further validated by controlling the biaxial stress of GaN-based LEDs with different sapphire substrate thicknesses. This work provides a method for direct observation of the biaxial stress effect on efficiency droop in LEDs under electrical injection.

  5. Direct Observation of the Biaxial Stress Effect on Efficiency Droop in GaN-based Light-emitting Diode under Electrical Injection

    PubMed Central

    Zheng, Jinjian; Li, Shuiqing; Chou, Chilun; Lin, Wei; Xun, Feilin; Guo, Fei; Zheng, Tongchang; Li, Shuping; Kang, Junyong

    2015-01-01

    Light-emitting diode (LED) efficiency has attracted considerable interest because of the extended use of solid-state lighting. Owing to lack of direct measurement, identification of the reasons for efficiency droop has been restricted. A direct measurement technique is developed in this work for characterization of biaxial stress in GaN-based blue LEDs under electrical injection. The Raman shift of the GaN E2 mode evidently decreases by 4.4 cm−1 as the driving current on GaN-based LEDs increases to 700 mA. Biaxial compressive stress is released initially and biaxial tensile stress builds up as the current increases with respect to the value of stress-free GaN. First-principles calculations reveal that electron accumulation is responsible for the stress variation in InxGa1−xN/GaN quantum wells, and then reduces the transition probability among quantum levels. This behavior is consistent with the measured current-dependent external quantum efficiency. The rule of biaxial stress-dependent efficiency is further validated by controlling the biaxial stress of GaN-based LEDs with different sapphire substrate thicknesses. This work provides a method for direct observation of the biaxial stress effect on efficiency droop in LEDs under electrical injection. PMID:26634816

  6. Platelet-rich plasma for chronic lateral epicondylitis: is one injection sufficient?

    PubMed

    Glanzmann, Michael C; Audigé, Laurent

    2015-12-01

    Chronic lateral epicondylitis is generally treated using nonsurgical methods including physiotherapy and infiltrations of cortisone or platelet-rich plasma (PRP). The latter is known for its simple application as well as associated low risk of adverse events, which lend to its widespread use in treating various musculoskeletal conditions. There is limited evidence on the effectiveness of PRP injections to optimally treat chronic lateral epicondylitis. This study explored the effectiveness of single or repeated injections for patients with symptoms that spanned 6 months or more and were unresponsive to alternate conservative measures. Patients with chronic lateral epicondylitis received PRP injections in 4-week intervals that were complemented with standardized physical therapy. Patient-reported outcomes based on the patient-rated elbow evaluation (PREE), quick disabilities of the arm, shoulder and hand (qDASH), and EuroQol (five dimensions) 3-level version (EQ5D3L) questionnaires were documented at each visit including 6 months after the first injection. These outcomes were compared between patients receiving 1 vs. 2 or 3 PRP injections. Sixty-two patients received one (n = 36) or more (n = 26) PRP injections. The mean baseline to 6-month follow-up scores of the PREE and qDASH questionnaires improved significantly from 54.0 to 23.0 and 50.3 to 20.7, respectively. The mean baseline EQ5D3L-visual analogue scale score improved from 62.5 to 82.9 by 6 months post-injection. These outcomes did not significantly differ between the patients who received varying numbers of injections. Patients with chronic lateral epicondylitis reported significant pain relief and gain in function as well as quality of life 6 months after localized PRP treatment. A single PRP injection may be sufficient.

  7. Microdistribution of fluorescently-labeled monoclonal antibody in a peritoneal dissemination model of ovarian cancer

    NASA Astrophysics Data System (ADS)

    Kosaka, Nobuyuki; Ogawa, Mikako; Paik, David S.; Paik, Chang H.; Choyke, Peter L.; Kobayashi, Hisataka

    2010-02-01

    The microdistribution of therapeutic monoclonal antibodies within a tumor is important for determining clinical response. Nonuniform microdistribution predicts therapy failure. Herein, we developed a semiquantitative method for measuring microdistribution of an antibody within a tumor using in situ fluorescence microscopy and sought to modulate the microdistribution by altering the route and timing of antibody dosing. The microdistribution of a fluorescently-labeled antibody, trastuzumab (50-μg and 150-μg intraperitoneal injection (i.p.), and 100-μg intravenous injection (i.v.)) was evaluated in a peritoneal dissemination mouse model of ovarian cancer. In addition, we evaluated the microdistribution of concurrently-injected (30-μg i.p. and 100-μg i.v.) or serial (two doses of 30-μg i.p.) trastuzumab using in situ multicolor fluorescence microscopy. After the administration of 50-μg i.p. and 100-μg i.v. trastuzumab fluorescence imaging showed no significant difference in the central to peripheral signal ratio (C/P ratio) and demonstrated a peripheral-dominant accumulation, whereas administration of 150-μg i.p. trastuzumab showed relatively uniform, central dominant accumulation. With concurrent-i.p.-i.v. injections trastuzumab showed slightly higher C/P ratio than concurrently-injected i.p. trastuzumab. Moreover, in the serial injection study, the second injection of trastuzumab distributed more centrally than the first injection, while no difference was observed in the control group. Our results suggest that injection routes do not affect the microdistribution pattern of antibody in small peritoneal disseminations. However, increasing the dose results in a more uniform antibody distribution within peritoneal nodules. Furthermore, the serial i.p. injection of antibody can modify the microdistribution within tumor nodules. This work has implications for the optimal delivery of antibody based cancer therapies.

  8. Enduring Consequences From the War on Drugs: How Policing Practices Impact HIV Risk Among People Who Inject Drugs in Baltimore City.

    PubMed

    Flath, Natalie; Tobin, Karin; King, Kelly; Lee, Alexandra; Latkin, Carl

    2017-07-03

    Neighborhood-level characteristics, including police activity, are associated with HIV and Hepatitis C injection risk-behaviors among people who inject drugs (PWID). However, the pathways through which these neighborhood perceptions shape individual-level HIV risk behaviors are unclear. This study helps to explain perceived behaviors between perceived neighborhood police activity and HIV injection risk behavior (i.e., injection syringe/tool sharing in the previous 6 months). A sample of (n = 366) PWIDs who self-reported recent use were recruited using community-based outreach methods in Baltimore, Maryland. Neighborhood police perceptions were assessed by asking participants whether they would (1) be more likely to ask others to share injection tools in the context of heightened police activity and (2) be less likely to carry syringes with them due to fear of arrest. Poisson regression with robust variance was used to identify statistical relationships. Recent police encounters, frequency of heroin injection, and sociodemographic characteristics were controlled for in the model. Neighborhood police perceptions shaped injection-risk behavior. Half of the sample (49%) reported an aversion of carrying personal syringes, due to fear of arrest. Those who agreed they would be more likely to ask others to share injection equipment in the context of heightened police activity were more likely to share syringes (21% vs. 3%, p <.01). Adjusted models showed that syringe sharing was independently associated with asking to borrow equipment in neighborhoods with perceived heightened police activity (aPR: 2.22, 95% confidence interval (CI): 1.7, 3.0). This study sheds light on how police perceptions may influence injection risk behavior. While these relationships require further elucidation, this study suggests that public health interventions aiming to reduce HIV risk would benefit from improving community-police relationships.

  9. Sensor for Injection Rate Measurements

    PubMed Central

    Marcic, Milan

    2006-01-01

    A vast majority of the medium and high speed Diesel engines are equipped with multi-hole injection nozzles nowadays. Inaccuracies in workmanship and changing hydraulic conditions in the nozzles result in differences in injection rates between individual injection nozzle holes. The new deformational measuring method described in the paper allows injection rate measurement in each injection nozzle hole. The differences in injection rates lead to uneven thermal loads of Diesel engine combustion chambers. All today known measuring method, such as Bosch and Zeuch give accurate results of the injection rate in diesel single-hole nozzles. With multihole nozzles they tell us nothing about possible differences in injection rates between individual holes of the nozzle. At deformational measuring method, the criterion of the injected fuel is expressed by the deformation of membrane occurring due to the collision of the pressure wave against the membrane. The pressure wave is generated by the injection of the fuel into the measuring space. For each hole of the nozzle the measuring device must have a measuring space of its own into which fuel is injected as well as its measuring membrane and its own fuel outlet. During measurements procedure the measuring space must be filled with fuel to maintain an overpressure of 5 kPa. Fuel escaping from the measuring device is conducted into the graduated cylinders for measuring the volumetric flow through each hole of the nozzle.The membrane deformation is assessed by strain gauges. They are glued to the membrane and forming the full Wheatstone's bridge. We devoted special attention to the membrane shape and temperature compensation of the strain gauges.

  10. [Reliability theory based on quality risk network analysis for Chinese medicine injection].

    PubMed

    Li, Zheng; Kang, Li-Yuan; Fan, Xiao-Hui

    2014-08-01

    A new risk analysis method based upon reliability theory was introduced in this paper for the quality risk management of Chinese medicine injection manufacturing plants. The risk events including both cause and effect ones were derived in the framework as nodes with a Bayesian network analysis approach. It thus transforms the risk analysis results from failure mode and effect analysis (FMEA) into a Bayesian network platform. With its structure and parameters determined, the network can be used to evaluate the system reliability quantitatively with probabilistic analytical appraoches. Using network analysis tools such as GeNie and AgenaRisk, we are able to find the nodes that are most critical to influence the system reliability. The importance of each node to the system can be quantitatively evaluated by calculating the effect of the node on the overall risk, and minimization plan can be determined accordingly to reduce their influences and improve the system reliability. Using the Shengmai injection manufacturing plant of SZYY Ltd as a user case, we analyzed the quality risk with both static FMEA analysis and dynamic Bayesian Network analysis. The potential risk factors for the quality of Shengmai injection manufacturing were identified with the network analysis platform. Quality assurance actions were further defined to reduce the risk and improve the product quality.

  11. Employment-based reinforcement of adherence to an FDA approved extended release formulation of naltrexone in opioid-dependent adults: a randomized controlled trial.

    PubMed

    DeFulio, Anthony; Everly, Jeffrey J; Leoutsakos, Jeannie-Marie S; Umbricht, Annie; Fingerhood, Michael; Bigelow, George E; Silverman, Kenneth

    2012-01-01

    Naltrexone provides excellent opioid blockade, but its clinical utility is limited because opioid-dependent patients typically refuse it. An injectable suspension of naltrexone for extended release (XR-NTX) was recently approved by the FDA for treatment of opioid dependence. XR-NTX treatment may require concurrent behavioral intervention to maximize adherence and effectiveness, thus we sought to evaluate employment-based reinforcement as a method of improving adherence to XR-NTX in opiate dependent adults. Opioid-dependent adults (n=38) were detoxified and inducted onto oral naltrexone, then randomly assigned to contingency or prescription conditions. Participants received up to six doses of XR-NTX at four-week intervals. All participants could earn vouchers for attendance and performance at a therapeutic workplace. Contingency participants were required to accept XR-NTX injections to access the workplace and earn vouchers. Prescription participants could earn vouchers independent of their acceptance of XR-NTX injections. Contingency participants accepted significantly more naltrexone injections than prescription participants (87% versus 52%, p=.002), and were more likely to accept all injections (74% versus 26%, p=.004). Participants in the two conditions provided similar percentages of samples negative for opiates (72% versus 65%) and for cocaine (58% versus 54%). Opiate positivity was significantly more likely when samples were also cocaine positive, independent of naltrexone blockade (p=.002). Long-term adherence to XR-NTX in unemployed opiate dependent adults is low under usual care conditions. Employment-based reinforcement can maintain adherence to XR-NTX. Ongoing cocaine use appears to interfere with the clinical effectiveness of XR-NTX on opiate use. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  12. Optical Injection Locking of Vertical Cavity Surface-Emitting Lasers: Digital and Analog Applications

    NASA Astrophysics Data System (ADS)

    Parekh, Devang

    With the rise of mobile (cellphones, tablets, notebooks, etc.) and broadband wireline communications (Fiber to the Home), there are increasing demands being placed on transmitters for moving data from device to device and around the world. Digital and analog fiber-optic communications have been the key technology to meet this challenge, ushering in ubiquitous Internet and cable TV over the past 20 years. At the physical layer, high-volume low-cost manufacturing of semiconductor optoelectronic devices has played an integral role in allowing for deployment of high-speed communication links. In particular, vertical cavity surface emitting lasers (VCSEL) have revolutionized short reach communications and are poised to enter more markets due to their low cost, small size, and performance. However, VCSELs have disadvantages such as limited modulation performance and large frequency chirp which limits fiber transmission speed and distance, key parameters for many fiber-optic communication systems. Optical injection locking is one method to overcome these limitations without re-engineering the VCSEL at the device level. By locking the frequency and phase of the VCSEL by the direct injection of light from another laser oscillator, improved device performance is achieved in a post-fabrication method. In this dissertation, optical injection locking of VCSELs is investigated from an applications perspective. Optical injection locking of VCSELs can be used as a pathway to reduce complexity, cost, and size of both digital and analog fiber-optic communications. On the digital front, reduction of frequency chirp via bit pattern inversion for large-signal modulation is experimentally demonstrated showing up to 10 times reduction in frequency chirp and over 90 times increase in fiber transmission distance. Based on these results, a new reflection-based interferometric model for optical injection locking was established to explain this phenomenon. On the analog side, the resonance frequency enhancement was exploited for millimeter-wave radio over fiber communications. Experimental demonstration of 4 Gb/s data transmission over 20 km of fiber and 3 m of wireless transmission at a 60 GHz carrier frequency was achieved. Additionally, optical injection of multi-transverse mode (MM) VCSELs was investigated showing record resonance frequency enhancement of > 54 GHz and 3-dB bandwidth of 38 GHz. Besides these applications, a number of other intriguing applications are also discussed, including an optoelectronic oscillator (OEO) and wavelength-division multiplexed passive optical networks (WDM-PON). Finally, the future of optical injection locking and its direction going forward will be discussed.

  13. Coupled Hydro-Mechanical Modeling of Fluid Geological Storage

    NASA Astrophysics Data System (ADS)

    Castelletto, N.; Garipov, T.; Tchelepi, H. A.

    2013-12-01

    The accurate modeling of the complex coupled physical processes occurring during the injection and the post-injection period is a key factor for assessing the safety and the feasibility of anthropogenic carbon dioxide (CO2) sequestration in subsurface formations. In recent years, it has become widely accepted the importance of the coupling between fluid flow and geomechanical response in constraining the sustainable pressure buildup caused by fluid injection relative to the caprock sealing capacity, induced seismicity effects and ground surface stability [e.g., Rutqvist, 2012; Castelletto et al., 2013]. Here, we present a modeling approach based on a suitable combination of Finite Volumes (FVs) and Finite Elements (FEs) to solve the coupled system of partial differential equations governing the multiphase flow in a deformable porous medium. Specifically, a FV method is used for the flow problem while the FE method is adopted to address the poro-elasto-plasticity equations. The aim of the present work is to compare the performance and the robustness of unconditionally stable sequential-implicit schemes [Kim et al., 2011] and the fully-implicit method in solving the algebraic systems arising from the discretization of the governing equations, for both normally conditioned and severely ill-conditioned problems. The two approaches are tested against well-known analytical solutions and experimented with in a realistic application of CO2 injection in a synthetic aquifer. References: - Castelletto N., G. Gambolati, and P. Teatini (2013), Geological CO2 sequestration in multi-compartment reservoirs: Geomechanical challenges, J. Geophys. Res. Solid Earth, 118, 2417-2428, doi:10.1002/jgrb.50180. - Kim J., H. A. Tchelepi, and R. Juanes (2011), Stability, accuracy and efficiency of sequential methods for coupled flow and geomechanics, SPE J., 16(2), 249-262. - Rutqvist J. (2012), The geomechanics of CO2 storage in deep sedimentary formations, Geotech. Geol. Eng., 30, 525-551.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedmann, S J

    Carbon capture and sequestration (CCS) has emerged as a key technology for dramatic short-term reduction in greenhouse gas emissions in particular from large stationary. A key challenge in this arena is the monitoring and verification (M&V) of CO2 plumes in the deep subsurface. Towards that end, we have developed a tool that can simultaneously invert multiple sub-surface data sets to constrain the location, geometry, and saturation of subsurface CO2 plumes. We have focused on a suite of unconventional geophysical approaches that measure changes in electrical properties (electrical resistance tomography, electromagnetic induction tomography) and bulk crustal deformation (til-meters). We had alsomore » used constraints of the geology as rendered in a shared earth model (ShEM) and of the injection (e.g., total injected CO{sub 2}). We describe a stochastic inversion method for mapping subsurface regions where CO{sub 2} saturation is changing. The technique combines prior information with measurements of injected CO{sub 2} volume, reservoir deformation and electrical resistivity. Bayesian inference and a Metropolis simulation algorithm form the basis for this approach. The method can (a) jointly reconstruct disparate data types such as surface or subsurface tilt, electrical resistivity, and injected CO{sub 2} volume measurements, (b) provide quantitative measures of the result uncertainty, (c) identify competing models when the available data are insufficient to definitively identify a single optimal model and (d) rank the alternative models based on how well they fit available data. We present results from general simulations of a hypothetical case derived from a real site. We also apply the technique to a field in Wyoming, where measurements collected during CO{sub 2} injection for enhanced oil recovery serve to illustrate the method's performance. The stochastic inversions provide estimates of the most probable location, shape, volume of the plume and most likely CO{sub 2} saturation. The results suggest that the method can reconstruct data with poor signal to noise ratio and use hard constraints available from many sites and applications. External interest in the approach and method is high, and already commercial and DOE entities have requested technical work using the newly developed methodology for CO{sub 2} monitoring.« less

  15. A Review of Metal Injection Molding- Process, Optimization, Defects and Microwave Sintering on WC-Co Cemented Carbide

    NASA Astrophysics Data System (ADS)

    Shahbudin, S. N. A.; Othman, M. H.; Amin, Sri Yulis M.; Ibrahim, M. H. I.

    2017-08-01

    This article is about a review of optimization of metal injection molding and microwave sintering process on tungsten cemented carbide produce by metal injection molding process. In this study, the process parameters for the metal injection molding were optimized using Taguchi method. Taguchi methods have been used widely in engineering analysis to optimize the performance characteristics through the setting of design parameters. Microwave sintering is a process generally being used in powder metallurgy over the conventional method. It has typical characteristics such as accelerated heating rate, shortened processing cycle, high energy efficiency, fine and homogeneous microstructure, and enhanced mechanical performance, which is beneficial to prepare nanostructured cemented carbides in metal injection molding. Besides that, with an advanced and promising technology, metal injection molding has proven that can produce cemented carbides. Cemented tungsten carbide hard metal has been used widely in various applications due to its desirable combination of mechanical, physical, and chemical properties. Moreover, areas of study include common defects in metal injection molding and application of microwave sintering itself has been discussed in this paper.

  16. Fabrication and Characterization of All-Polystyrene Microfluidic Devices with Integrated Electrodes and Tubing.

    PubMed

    Pentecost, Amber M; Martin, R Scott

    2015-01-01

    A new method of fabricating all-polystyrene devices with integrated electrodes and fluidic tubing is described. As opposed to expensive polystyrene (PS) fabrication techniques that use hot embossing and bonding with a heated lab press, this approach involves solvent-based etching of channels and lamination-based bonding of a PS cover, all of which do not need to occur in a clean room. PS has been studied as an alternative microchip substrate to PDMS, as it is more hydrophilic, biologically compatible in terms of cell adhesion, and less prone to absorption of hydrophobic molecules. The etching/lamination-based method described here results in a variety of all-PS devices, with or without electrodes and tubing. To characterize the devices, micrographs of etched channels (straight and intersected channels) were taken using confocal and scanning electron microscopy. Microchip-based electrophoresis with repetitive injections of fluorescein was conducted using a three-sided PS (etched pinched, twin-tee channel) and one-sided PDMS device. Microchip-based flow injection analysis, with dopamine and NO as analytes, was used to characterize the performance of all-PS devices with embedded tubing and electrodes. Limits of detection for dopamine and NO were 130 nM and 1.8 μM, respectively. Cell immobilization studies were also conducted to assess all-PS devices for cellular analysis. This paper demonstrates that these easy to fabricate devices can be attractive alternative to other PS fabrication methods for a wide variety of analytical and cell culture applications.

  17. Enhancement of Cell-Based Therapeutic Angiogenesis Using a Novel Type of Injectable Scaffolds of Hydroxyapatite-Polymer Nanocomposite Microspheres

    PubMed Central

    Koyama, Hidenori; Okada, Masahiro; Tanaka, Shinji; Shoji, Tetsuo; Emoto, Masanori; Furuzono, Tsutomu; Nishizawa, Yoshiki; Inaba, Masaaki

    2012-01-01

    Background Clinical trials demonstrate the effectiveness of cell-based therapeutic angiogenesis in patients with severe ischemic diseases; however, their success remains limited. Maintaining transplanted cells in place are expected to augment the cell-based therapeutic angiogenesis. We have reported that nano-hydroxyapatite (HAp) coating on medical devices shows marked cell adhesiveness. Using this nanotechnology, HAp-coated poly(l-lactic acid) (PLLA) microspheres, named nano-scaffold (NS), were generated as a non-biological, biodegradable and injectable cell scaffold. We investigate the effectiveness of NS on cell-based therapeutic angiogenesis. Methods and Results Bone marrow mononuclear cells (BMNC) and NS or control PLLA microspheres (LA) were intramuscularly co-implanted into mice ischemic hindlimbs. When BMNC derived from enhanced green fluorescent protein (EGFP)-transgenic mice were injected into ischemic muscle, the muscle GFP level in NS+BMNC group was approximate fivefold higher than that in BMNC or LA+BMNC groups seven days after operation. Kaplan-Meier analysis demonstrated that NS+BMNC markedly prevented hindlimb necrosis (P<0.05 vs. BMNC or LA+BMNC). NS+BMNC revealed much higher induction of angiogenesis in ischemic tissues and collateral blood flow confirmed by three-dimensional computed tomography angiography than those of BMNC or LA+BMNC groups. NS-enhanced therapeutic angiogenesis and arteriogenesis showed good correlations with increased intramuscular levels of vascular endothelial growth factor and fibroblast growth factor-2. NS co-implantation also prevented apoptotic cell death of transplanted cells, resulting in prolonged cell retention. Conclusion A novel and feasible injectable cell scaffold potentiates cell-based therapeutic angiogenesis, which could be extremely useful for the treatment of severe ischemic disorders. PMID:22529991

  18. Recent Development in Optical Chemical Sensors Coupling with Flow Injection Analysis

    PubMed Central

    Ojeda, Catalina Bosch; Rojas, Fuensanta Sánchez

    2006-01-01

    Optical techniques for chemical analysis are well established and sensors based on these techniques are now attracting considerable attention because of their importance in applications such as environmental monitoring, biomedical sensing, and industrial process control. On the other hand, flow injection analysis (FIA) is advisable for the rapid analysis of microliter volume samples and can be interfaced directly to the chemical process. The FIA has become a widespread automatic analytical method for more reasons; mainly due to the simplicity and low cost of the setups, their versatility, and ease of assembling. In this paper, an overview of flow injection determinations by using optical chemical sensors is provided, and instrumentation, sensor design, and applications are discussed. This work summarizes the most relevant manuscripts from 1980 to date referred to analysis using optical chemical sensors in FIA.

  19. Electron acceleration by a tightly focused Hermite-Gaussian beam: higher-order corrections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao Zhiguo; Institute of Laser Physics and Chemistry, Sichuan University, Chengdu 610064; Yang Dangxiao

    2008-03-15

    Taking the TEM{sub 1,0}-mode Hermite-Gaussian (H-G) beam as a numerical calculation example, and based on the method of the perturbation series expansion, the higher-order field corrections of H-G beams are derived and used to study the electron acceleration by a tightly focused H-G beam in vacuum. For the case of the off-axis injection the field corrections to the terms of order f{sup 3} (f=1/kw{sub 0}, k and w{sub 0} being the wavenumber and waist width, respectively) are considered, and for the case of the on-axis injection the contributions of the terms of higher orders are negligible. By a suitable optimizationmore » of injection parameters the energy gain in the giga-electron-volt regime can be achieved.« less

  20. Crack Cocaine Injection Practices and HIV Risk: Findings From New York and Bridgeport

    PubMed Central

    Lankenau, Stephen E.; Clatts, Michael C.; Goldsamt, Lloyd A.; Welle, Dorinda L.

    2007-01-01

    This article examines the behavioral practices and health risks associated with preparing crack cocaine for injection. Using an ethno-epidemiological approach, injection drug users (n=38) were recruited between 1999 and 2000 from public settings in New York City and Bridgeport, Connecticut and responded to a semistructured interview focusing on crack injection initiation and their most recent crack injection. Study findings indicate that methods of preparing crack for injection were impacted by a transforming agent, heat applied to the “cooker,” heroin use, age of the injector, and geographic location of the injector. The findings suggest that crack injectors use a variety of methods to prepare crack, which may carry different risks for the transmission of bloodborne pathogens. In particular, crack injection may be an important factor in the current HIV epidemic. PMID:18079990

  1. Fully automated analytical procedure for propofol determination by sequential injection technique with spectrophotometric and fluorimetric detections.

    PubMed

    Šrámková, Ivana; Amorim, Célia G; Sklenářová, Hana; Montenegro, Maria C B M; Horstkotte, Burkhard; Araújo, Alberto N; Solich, Petr

    2014-01-01

    In this work, an application of an enzymatic reaction for the determination of the highly hydrophobic drug propofol in emulsion dosage form is presented. Emulsions represent a complex and therefore challenging matrix for analysis. Ethanol was used for breakage of a lipid emulsion, which enabled optical detection. A fully automated method based on Sequential Injection Analysis was developed, allowing propofol determination without the requirement of tedious sample pre-treatment. The method was based on spectrophotometric detection after the enzymatic oxidation catalysed by horseradish peroxidase and subsequent coupling with 4-aminoantipyrine leading to a coloured product with an absorbance maximum at 485 nm. This procedure was compared with a simple fluorimetric method, which was based on the direct selective fluorescence emission of propofol in ethanol at 347 nm. Both methods provide comparable validation parameters with linear working ranges of 0.005-0.100 mg mL(-1) and 0.004-0.243 mg mL(-1) for the spectrophotometric and fluorimetric methods, respectively. The detection and quantitation limits achieved with the spectrophotometric method were 0.0016 and 0.0053 mg mL(-1), respectively. The fluorimetric method provided the detection limit of 0.0013 mg mL(-1) and limit of quantitation of 0.0043 mg mL(-1). The RSD did not exceed 5% and 2% (n=10), correspondingly. A sample throughput of approx. 14 h(-1) for the spectrophotometric and 68 h(-1) for the fluorimetric detection was achieved. Both methods proved to be suitable for the determination of propofol in pharmaceutical formulation with average recovery values of 98.1 and 98.5%. © 2013 Elsevier B.V. All rights reserved.

  2. Bioengineering of injectable encapsulated aggregates of pluripotent stem cells for therapy of myocardial infarction

    NASA Astrophysics Data System (ADS)

    Zhao, Shuting; Xu, Zhaobin; Wang, Hai; Reese, Benjamin E.; Gushchina, Liubov V.; Jiang, Meng; Agarwal, Pranay; Xu, Jiangsheng; Zhang, Mingjun; Shen, Rulong; Liu, Zhenguo; Weisleder, Noah; He, Xiaoming

    2016-10-01

    It is difficult to achieve minimally invasive injectable cell delivery while maintaining high cell retention and animal survival for in vivo stem cell therapy of myocardial infarction. Here we show that pluripotent stem cell aggregates pre-differentiated into the early cardiac lineage and encapsulated in a biocompatible and biodegradable micromatrix, are suitable for injectable delivery. This method significantly improves the survival of the injected cells by more than six-fold compared with the conventional practice of injecting single cells, and effectively prevents teratoma formation. Moreover, this method significantly enhances cardiac function and survival of animals after myocardial infarction, as a result of a localized immunosuppression effect of the micromatrix and the in situ cardiac regeneration by the injected cells.

  3. Zwitterionic, cationic, and anionic fluorinated chemicals in aqueous film forming foam formulations and groundwater from U.S. military bases by nonaqueous large-volume injection HPLC-MS/MS.

    PubMed

    Backe, Will J; Day, Thomas C; Field, Jennifer A

    2013-05-21

    A new analytical method was developed to quantify 26 newly-identified and 21 legacy (e.g. perfluoroalkyl carboxylates, perfluoroalkyl sulfonates, and fluorotelomer sulfonates) per and polyfluorinated alkyl substances (PFAS) in groundwater and aqueous film forming foam (AFFF) formulations. Prior to analysis, AFFF formulations were diluted into methanol and PFAS in groundwater were micro liquid-liquid extracted. Methanolic dilutions of AFFF formulations and groundwater extracts were analyzed by large-volume injection (900 μL) high-performance liquid chromatography tandem mass spectrometry. Orthogonal chromatography was performed using cation exchange (silica) and anion exchange (propylamine) guard columns connected in series to a reverse-phase (C18) analytical column. Method detection limits for PFAS in groundwater ranged from 0.71 ng/L to 67 ng/L, and whole-method accuracy ranged from 96% to 106% for analytes for which matched authentic analytical standards were available. For analytes without authentic analytical standards, whole-method accuracy ranged from 78 % to 144 %, and whole-method precision was less than 15 % relative standard deviation for all analytes. A demonstration of the method on groundwater samples from five military bases revealed eight of the 26 newly-identified PFAS present at concentrations up to 6900 ng/L. The newly-identified PFAS represent a minor fraction of the fluorinated chemicals in groundwater relative to legacy PFAS. The profiles of PFAS in groundwater differ from those found in fluorotelomer- and electrofluorination-based AFFF formulations, which potentially indicates environmental transformation of PFAS.

  4. Lime Juice and Vinegar Injections as a Cheap and Natural Alternative to Control COTS Outbreaks.

    PubMed

    Moutardier, Grégoire; Gereva, Sompert; Mills, Suzanne C; Adjeroud, Mehdi; Beldade, Ricardo; Ham, Jayven; Kaku, Rocky; Dumas, Pascal

    2015-01-01

    Outbreaks of the corallivorous crown-of-thorns seastar Acanthaster planci (COTS) represent one of the greatest disturbances to coral reef ecosystems in the Indo-Pacific, affecting not only coral reefs but also the coastal communities which rely on their resources. While injection approaches are increasingly used in an attempt to control COTS densities, most of them display severe drawbacks including logistical challenges, high residual environmental impacts or low cost-effectiveness. We tested a new alternative control method based upon acidic injections of cheap, 100% natural products. We investigated the lethal doses, intra- and inter-specific disease transmission and immune responses of COTS when injected with fresh lime juice (extracted from local Citrus arantifolia) and white spirit vinegar. High COTS mortality was achieved with small volumes: 10-20 ml per seastar induced death in 89%/97% of injected specimens after an average 34.3 h/29.8 h for lime juice and vinegar respectively. Highest efficiency was reached for both solutions with double shots of (2 × 10 ml) in two different areas on the body: 100% mortality occurred within 12-24 h, which is similar or faster compared with other current injection methods. Multiple immune measures suggested that death was very likely caused by pH stress from the acidic solutions rather than a bacterial infection. Contagion to either conspecifics or a variety of other reef species was not observed, even at COTS densities 15 times higher than the highest naturally reported. 10 to 20 l lime juice/vinegar could kill up to a thousand COTS at a cost of less than 0.05 USD per specimen; no permits or special handling procedures are required. We conclude that injections of lime juice and vinegar offer great advantages when compared to current best practises and constitute a cheap and natural option for all reefs affected by COTS.

  5. Lime Juice and Vinegar Injections as a Cheap and Natural Alternative to Control COTS Outbreaks

    PubMed Central

    Moutardier, Grégoire; Gereva, Sompert; Mills, Suzanne C.; Adjeroud, Mehdi; Beldade, Ricardo; Ham, Jayven; Kaku, Rocky; Dumas, Pascal

    2015-01-01

    Outbreaks of the corallivorous crown-of-thorns seastar Acanthaster planci (COTS) represent one of the greatest disturbances to coral reef ecosystems in the Indo-Pacific, affecting not only coral reefs but also the coastal communities which rely on their resources. While injection approaches are increasingly used in an attempt to control COTS densities, most of them display severe drawbacks including logistical challenges, high residual environmental impacts or low cost-effectiveness. We tested a new alternative control method based upon acidic injections of cheap, 100% natural products. We investigated the lethal doses, intra- and inter-specific disease transmission and immune responses of COTS when injected with fresh lime juice (extracted from local Citrus arantifolia) and white spirit vinegar. High COTS mortality was achieved with small volumes: 10–20 ml per seastar induced death in 89%/97% of injected specimens after an average 34.3 h/29.8 h for lime juice and vinegar respectively. Highest efficiency was reached for both solutions with double shots of (2 × 10 ml) in two different areas on the body: 100% mortality occurred within 12–24 h, which is similar or faster compared with other current injection methods. Multiple immune measures suggested that death was very likely caused by pH stress from the acidic solutions rather than a bacterial infection. Contagion to either conspecifics or a variety of other reef species was not observed, even at COTS densities 15 times higher than the highest naturally reported. 10 to 20 l lime juice/vinegar could kill up to a thousand COTS at a cost of less than 0.05 USD per specimen; no permits or special handling procedures are required. We conclude that injections of lime juice and vinegar offer great advantages when compared to current best practises and constitute a cheap and natural option for all reefs affected by COTS. PMID:26356840

  6. A general method for the purification of synthetic oligodeoxyribonucleotides containing strong secondary structure by reversed-phase high-performance liquid chromatography on PRP-1 resin.

    PubMed

    Germann, M W; Pon, R T; van de Sande, J H

    1987-09-01

    Synthetic 5'-dimethoxytritylated oligodeoxyribonucleotides, which contained strong secondary structure, were satisfactorily denatured and purified by reversed-phase HPLC on PRP-1 columns when strongly alkaline conditions (0.05 M NaOH) were employed. This procedure was suitable for the purification of hairpin structures, e.g., d(CG)nT4(CG)n (n = 4, 5, 6), and oligo(dG) sequences, e.g., d(G)24, as well as oligodeoxyribonucleotide probes which contained degenerate base sites. Oligodeoxyribonucleotides as long as 50 bases in length were purified. Recovery of injected oligonucleotides was typically 90% or better. The high capacity of the PRP-1 resin also allowed purification to be performed on a preparative scale (2-8 mg per injection). Enzymatic degradation and HPLC analysis indicated that no modification of the heterocyclic bases occurred under the alkaline conditions described.

  7. Drug delivery into the cochlear apex: Improved control to sequentially affect finely spaced regions along the entire length of the cochlear spiral.

    PubMed

    Lichtenhan, J T; Hartsock, J; Dornhoffer, J R; Donovan, K M; Salt, A N

    2016-11-01

    Administering pharmaceuticals to the scala tympani of the inner ear is a common approach to study cochlear physiology and mechanics. We present here a novel method for in vivo drug delivery in a controlled manner to sealed ears. Injections of ototoxic solutions were applied from a pipette sealed into a fenestra in the cochlear apex, progressively driving solutions along the length of scala tympani toward the cochlear aqueduct at the base. Drugs can be delivered rapidly or slowly. In this report we focus on slow delivery in which the injection rate is automatically adjusted to account for varying cross sectional area of the scala tympani, therefore driving a solution front at uniform rate. Objective measurements originating from finely spaced, low- to high-characteristic cochlear frequency places were sequentially affected. Comparison with existing methods(s): Controlled administration of pharmaceuticals into the cochlear apex overcomes a number of serious limitations of previously established methods such as cochlear perfusions with an injection pipette in the cochlear base: The drug concentration achieved is more precisely controlled, drug concentrations remain in scala tympani and are not rapidly washed out by cerebrospinal fluid flow, and the entire length of the cochlear spiral can be treated quickly or slowly with time. Controlled administration of solutions into the cochlear apex can be a powerful approach to sequentially effect objective measurements originating from finely spaced cochlear regions and allows, for the first time, the spatial origin of CAPs to be objectively defined. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Regional myocardial flow and capillary permeability-surface area products are nearly proportional.

    PubMed

    Caldwell, J H; Martin, G V; Raymond, G M; Bassingthwaighte, J B

    1994-08-01

    Analyses of data on the transcapillary exchange and cellular uptake in the normal heart have generally been based on the assumption that local membrane conductances and volumes of distribution are everywhere the same. The question is whether such an assumption is justified in view of the marked (sixfold) heterogeneity of local blood flows per gram tissue. The method was to estimate both flow and capillary membrane permeability-surface area products (PS) locally in the heart. For each of five dogs running on a sloped treadmill, the deposition of tracer microspheres and of [131I]iodophenylpentadecanoic acid (IPPA), after left atrial injection, was determined in 256 pieces of left ventricular myocardium by killing the animals at approximately 100 s after radiotracer injection. A hydraulic occluder stopped the flow to a portion of the myocardium supplied by the left circumflex coronary artery 30 s before tracer injection. Regional flows ranged from 0.1 to 7.0 ml.g-1.min-1. IPPA extractions ranged from 20 to 49%. Using the known flows, we assumed the applicability of an axially distributed blood-tissue exchange model to estimate the PS for the capillary (PSc) and the parenchymal cell. It was impossible to explain the data if the PSc values for membrane transport were uniform throughout the organ. Rather, the only reasonable descriptors of the data required that local PSc values increase with local flow, almost in proportion. Current methods of analysis using data based on deposition methods need to be revised to take into account the near proportionality of PS to flow for at least some substrates.

  9. High-Resolution Analysis of Seismicity Induced at Berlín Geothermal Field, El Salvador

    NASA Astrophysics Data System (ADS)

    Kwiatek, G.; Bulut, F.; Dresen, G. H.; Bohnhoff, M.

    2012-12-01

    We investigate induced microseismic activity monitored at Berlín Geothermal Field, El Salvador, during a hydraulic stimulation. The site was monitored for a time period of 17 months using thirteen 3-component seismic stations located in shallow boreholes. Three stimulations were performed in the well TR8A with a maximum injection rate and well head pressure of 160l/s and 130bar, respectively. For the entire time period of our analysis, the acquisition system recorded 581 events with moment magnitudes ranging between -0.5 and 3.7. The initial seismic catalog provided by the operator was substantially improved: 1) We re-picked P- and S-wave onsets and relocated the seismic events using the double-difference relocation algorithm based on cross-correlation derived differential arrival time data. Forward modeling was performed using a local 1D velocity model instead of homogeneous full-space. 2) We recalculated source parameters using the spectral fitting method and refined the results applying the spectral ratio method. We investigated the source parameters and spatial and temporal changes of the seismic activity based on the refined dataset and studied the correlation between seismic activity and production. The achieved hypocentral precision allowed resolving the spatiotemporal changes in seismic activity down to a scale of a few meters. The application of spectral ratio method significantly improved the quality of source parameters in a high-attenuating and complex geological environment. Of special interest is the largest event (Mw3.7) and its nucleation process. We investigate whether the refined seismic data display any signatures that the largest event is triggered by the shut-in of the well. We found seismic activity displaying clear spatial and temporal patterns that could be easily related to the amount of water injected into the well TR8A and other reinjection wells in the investigated area. The migration of seismicity outside of injection point is observed while injection rate is increasing. The locations of migrating seismic events are related to the existing fault system that is independently supported by calculated focal mechanisms. We found that the event migration occurs until the shut-in of the well. We observe that the large magnitude events are observed right after the shut-in, located in undamaged parts of the fault system. Results show that the following stimulation episodes require increased injection rate level (or increased well head pressure) to re-activate the seismic activity (Kaiser Effect, "Crustal memory" effect). The static stress drop values increase with the distance from injection point that is interpreted to be related to pore pressure perturbations introduced by stimulation of the injection well.

  10. Nerve growth factor injected into the gastric ulcer base incorporates into endothelial, neuronal, glial and epithelial cells: implications for angiogenesis, mucosal regeneration and ulcer healing.

    PubMed

    Tanigawa, T; Ahluwalia, A; Watanabe, T; Arakawa, T; Tarnawski, A S

    2015-08-01

    A previous study has demonstrated that locally administered growth factors such as epidermal growth factor, basic fibroblast growth factor and hepatocyte growth factor can accelerate healing of experimental gastric ulcers in rats. That study indicates that locally administered growth factors can exert potent biological effects resulting in enhanced gastric ulcers healing. However, the fate of injected growth factors, their retention and localization to specific cellular compartments have not been examined. In our preliminary study, we demonstrated that local injection of nerve growth factor to the base of experimental gastric ulcers dramatically accelerates ulcer healing, increases angiogenesis - new blood vessel formation, and improves the quality of vascular and epithelial regeneration. Before embarking on larger, definitive and time sequence studies, we wished to determine whether locally injected nerve growth factor is retained in gastric ulcer's tissues and taken up by specific cells during gastric ulcer healing. Gastric ulcers were induced in anesthetized rats by local application of acetic acid using standard methods; and, 60 min later fluorescein isothiocyanate-labeled nerve growth factor was injected locally to the ulcer base. Rats were euthanized 2, 5 and 10 days later. Gastric specimens were obtained and processed for histology. Unstained paraffin sections were examined under a fluorescence microscope, and the incorporation of fluorescein isothiocyanate-labeled nerve growth factor into various gastric tissue cells was determined and quantified. In addition, we performed immunostaining for S100β protein that is expressed in neural components. Five and ten days after ulcer induction labeled nerve growth factor (injected to the gastric ulcer base) was incorporated into endothelial cells of blood vessels, neuronal, glial and epithelial cells, myofibroblasts and muscle cells. This study demonstrates for the first time that during gastric ulcer healing locally administered exogenous nerve growth factor is retained in gastric tissue and is taken up by endothelial, neural, muscle and epithelial cells. This is likely the basis for the therapeutic action of locally administered nerve growth factor and its stimulation of angiogenesis, tissue regeneration and gastric ulcer healing.

  11. Determination of available phosphorus in soils by using a new extraction procedure and a flow injection amperometric system.

    PubMed

    Jakmunee, Jaroon; Junsomboon, Jaroon

    2009-09-15

    A new extraction procedure based on an off-line extraction column was proposed for extracting of available phosphorus from soils. The column was fabricated from a plastic syringe fitted at the bottom with a cotton wool and a piece of filter paper to support a soil sample. An aliquot (50 mL) of extracting solution (0.05 M HCl+0.0125 M H(2)SO(4)) was used to extract the sample under gravity flow and the eluate was collected in a polyethylene bottle. The extract was then analyzed for phosphorus contents by a simple flow injection amperometric system, employing a set of three-way solenoid valves as an injection valve. The method is based on the electrochemical reduction of 12-molybdophosphate which is produced on-line by the reaction of orthophosphate with acidic molybdate and the electrical current produced was directly proportional to the concentration of phosphate in range of 0.1-10.0 mg L(-1) PO(4)-P, with a detection limit of 0.02 mg L(-1). Relative standard for 11 replicate injections of 5 mg L(-1) PO(4)-P was 0.5%. A sample through put of 35 h(-1) was achieved, with consumption of 14 mg KCl, 10mg ammonium molybdate and 0.05 mL H(2)SO(4) per analysis. The detection system does not suffer from the interferences that are encountered in the photometric method such as colored substances, colloids, metal ions, silicate and refractive index effect (Schlieren effect). The results obtained by the column extraction procedure were well correlated with those obtained by the steady-state extraction procedure, but showed slightly higher extraction efficiency.

  12. Electrokinetic gated injection-based microfluidic system for quantitative analysis of hydrogen peroxide in individual HepG2 cells.

    PubMed

    Zhang, Xinyuan; Li, Qingling; Chen, Zhenzhen; Li, Hongmin; Xu, Kehua; Zhang, Lisheng; Tang, Bo

    2011-03-21

    A microfluidic system to determine hydrogen peroxide (H(2)O(2)) in individual HepG2 cells based on the electrokinetic gated injection was developed for the first time. A home-synthesized fluorescent probe, bis(p-methylbenzenesulfonate)dichlorofluorescein (FS), was employed to label intracellular H(2)O(2) in the intact cells. On a simple cross microchip, multiple single-cell operations, including single cell injection, cytolysis, electrophoresis separation and detection of H(2)O(2), were automatically carried out within 60 s using the electrokinetic gated injection and laser-induced fluorescence detection (LIFD). The performance of the method was evaluated under the optimal conditions. The linear calibration curve was over a range of 4.39-610 amol (R(2)=0.9994). The detection limit was 0.55 amol or 9.0×10(-10) M (S/N=3). The relative standard deviations (RSDs, n=6) of migration time and peak area were 1.4% and 4.8%, respectively. With the use of this method, the average content of H(2)O(2) in single HepG2 cells was found to be 16.09±9.84 amol (n=15). Separation efficiencies in excess of 17,000 theoretical plates for the cells were achieved. These results demonstrated that the efficient integration and automation of these single-cell operations enabled the sensitive, reproducible, and quantitative examination of intracellular H(2)O(2) at single-cell level. Owing to the advantages of simple microchip structure, controllable single-cell manipulation and ease in building, this platform provides a universal way to automatically determine other intracellular constituents within single cells. This journal is © The Royal Society of Chemistry 2011

  13. Effect of hydralazine on duration of soft tissue local anesthesia following dental treatment: a randomized clinical trial.

    PubMed

    Fakheran Esfahani, Omid; Pouraboutaleb, Mohammad Fazel; Khorami, Behnam

    2015-01-01

    Prolonged numbness following routine dental treatments can cause difficulties in speaking and swallowing and may result in inadvertent biting of soft tissues. Local injection of vasodilator agents may represent a solution to this problem. The aim of this study was to evaluate the effect of submucosal injection of hydralazine hydrochloride (HCl) on the duration of oral soft tissue anesthesia after routine dental treatment. This randomized, single-blinded, controlled clinical trial included 50 patients who received inferior alveolar nerve block (2% lidocaine with 1:100,000 epinephrine) for simple restorative treatment. Upon completion of the dental treatment, patients randomly received a hydralazine HCl or sham injection in the same site as the local anesthetic injection. The reversal time to normal sensation of soft tissues (lips, tongue, and perioral skin) was evaluated and reported every 5 minutes by the patients, who followed an assessment protocol that they were taught in advance of treatment. Median recovery times in the hydralazine group and the sham group were 81.4 (SD, 3.6) and 221.8 (SD, 6.3) minutes, respectively. Based on Kaplan-Meier survival analysis, the duration of soft tissue anesthesia in the 2 groups was significantly different (P < 0.0001). By 1 hour after the reversal injection, 76% of subjects receiving hydralazine HCl had returned to normal intraoral and perioral sensation, but none of the subjects in the sham group reported normal sensation. Based on these results, submucosal injection of hydralazine HCl can be considered a safe and effective method to reduce the duration of local anesthetic-induced soft tissue numbness and the related functional problems.

  14. Model-based estimates of risks of disease transmission and economic costs of seven injection devices in sub-Saharan Africa.

    PubMed Central

    Ekwueme, Donatus U.; Weniger, Bruce G.; Chen, Robert T.

    2002-01-01

    OBJECTIVE: To investigate and compare seven types of injection devices for their risks of iatrogenic transmission of bloodborne pathogens and their economic costs in sub-Saharan Africa. METHODS: Risk assumptions for each device and cost models were constructed to estimate the number of new hepatitis B virus (HBV) and human immunodeficiency virus (HIV) infections resulting from patient-to-patient, patient-to-health care worker, and patient-to-community transmission. Costs of device purchase and usage were derived from the literature, while costs of direct medical care and lost productivity from HBV and HIV disease were based on data collected in 1999 in Côte d'Ivoire, Ghana, and Uganda. Multivariate sensitivity analyses using Monte Carlo simulation characterized uncertainties in model parameters. Costs were summed from both the societal and health care system payer's perspectives. FINDINGS: Resterilizable and disposable needles and syringes had the highest overall costs for device purchase, usage, and iatrogenic disease: median US dollars 26.77 and US dollars 25.29, respectively, per injection from the societal perspective. Disposable-cartridge jet injectors and automatic needle-shielding syringes had the lowest costs, US dollars 0.36 and US dollars 0.80, respectively. Reusable-nozzle jet injectors and auto-disable needle and syringes were intermediate, at US dollars 0.80 and US dollars 0.91, respectively, per injection. CONCLUSION: Despite their nominal purchase and usage costs, conventional needles and syringes carry a hidden but huge burden of iatrogenic disease. Alternative injection devices for the millions of injections administered annually in sub-Saharan Africa would be of value and should be considered by policy-makers in procurement decisions. PMID:12481207

  15. Aspects of numerical and representational methods related to the finite-difference simulation of advective and dispersive transport of freshwater in a thin brackish aquifer

    USGS Publications Warehouse

    Merritt, M.L.

    1993-01-01

    The simulation of the transport of injected freshwater in a thin brackish aquifer, overlain and underlain by confining layers containing more saline water, is shown to be influenced by the choice of the finite-difference approximation method, the algorithm for representing vertical advective and dispersive fluxes, and the values assigned to parametric coefficients that specify the degree of vertical dispersion and molecular diffusion that occurs. Computed potable water recovery efficiencies will differ depending upon the choice of algorithm and approximation method, as will dispersion coefficients estimated based on the calibration of simulations to match measured data. A comparison of centered and backward finite-difference approximation methods shows that substantially different transition zones between injected and native waters are depicted by the different methods, and computed recovery efficiencies vary greatly. Standard and experimental algorithms and a variety of values for molecular diffusivity, transverse dispersivity, and vertical scaling factor were compared in simulations of freshwater storage in a thin brackish aquifer. Computed recovery efficiencies vary considerably, and appreciable differences are observed in the distribution of injected freshwater in the various cases tested. The results demonstrate both a qualitatively different description of transport using the experimental algorithms and the interrelated influences of molecular diffusion and transverse dispersion on simulated recovery efficiency. When simulating natural aquifer flow in cross-section, flushing of the aquifer occurred for all tested coefficient choices using both standard and experimental algorithms. ?? 1993.

  16. A flow-injection mass spectrometry fingerprinting method for authentication and quality assessment of Scutellaria lateriflora-based dietary supplements

    USDA-ARS?s Scientific Manuscript database

    Scutellaria lateriflora, commonly known as skullcap, is used as an ingredient in numerous herbal products. However, it has been occasionally adulterated/contaminated with Teucrium canadense and/or Teucrium chamaedrys, commonly known as germander, due to the morphological similarities between the tw...

  17. Preparing neural stem/progenitor cells in PuraMatrix hydrogel for transplantation after brain injury in rats: A comparative methodological study.

    PubMed

    Aligholi, Hadi; Rezayat, Seyed Mahdi; Azari, Hassan; Ejtemaei Mehr, Shahram; Akbari, Mohammad; Modarres Mousavi, Seyed Mostafa; Attari, Fatemeh; Alipour, Fatemeh; Hassanzadeh, Gholamreza; Gorji, Ali

    2016-07-01

    Cultivation of neural stem/progenitor cells (NS/PCs) in PuraMatrix (PM) hydrogel is an option for stem cell transplantation. The efficacy of a novel method for placing adult rat NS/PCs in PM (injection method) was compared to encapsulation and surface plating approaches. In addition, the efficacy of injection method for transplantation of autologous NS/PCs was studied in a rat model of brain injury. NS/PCs were obtained from the subventricular zone (SVZ) and cultivated without (control) or with scaffold (three-dimensional cultures; 3D). The effect of different approaches on survival, proliferation, and differentiation of NS/PCs were investigated. In in vivo study, brain injury was induced 45 days after NS/PCs were harvested from the SVZ and phosphate buffered saline, PM, NS/PCs, or PM+NS/PCs were injected into the brain lesion. There was an increase in cell viability and proliferation after injection and surface plating of NS/PCs compared to encapsulation and neural differentiation markers were expressed seven days after culturing the cells. Using injection method, transplantation of NS/PCs cultured in PM resulted in significant reduction of lesion volume, improvement of neurological deficits, and enhancement of surviving cells. In addition, the transplanted cells could differentiate in to neurons, astrocytes, or oligodendrocytes. Our results indicate that the injection and surface plating methods enhanced cell survival and proliferation of NS/PCs and suggest the injection method as a promising approach for transplantation of NS/PCs in brain injury. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Comparison of incidence of intravascular injections during transforaminal epidural steroid injection using different needle types

    PubMed Central

    Lee, Yong Ho

    2014-01-01

    Background Infrequent but serious complications of transforaminal epidural steroid injection (TFESI) occur due to inadvertent intravascular injections. A few studies reported that the different needle types can influence on the occurrences of intravascular incidence in TFESI. This study prospectively evaluated whether short-bevel needle can reduce the incidences of intravascular injection of TFESI compared to long-bevel needles. Methods From March 2013 to December 2013, 239 consecutive patients were enrolled and received 249 fluoroscopically guided TFESI using the classic technique. Confirmation of intravascular spread was done initially with real time fluoroscopy and then with digital subtraction angiography method in a same patient. Injection technique for TFESI was the same for both short-bevel and long-bevel needle types. Results The incidences of intravascular injections with the long-bevel and short-bevel needles were 15.0% (21/140) and 9.2% (4/140), respectively. More than half of intravascular injections occurred simultaneously with epidural injections (8.0%, 20/249). There were no statistically significant differences between the long-bevel and the short-bevel needles in the rates of intravascular injections (P = 0.17). Conclusions Short-bevel needles did not demonstrate any benefits in reducing the incidence of intravascular injection. PMID:25302096

  19. Policy and programmatic considerations for introducing a longer-acting injectable contraceptive: perspectives of stakeholders from Kenya and Rwanda.

    PubMed

    McKenna, Kevin; Arcara, Jennet; Rademacher, Kate H; Mackenzie, Caroline; Ngabo, Fidele; Munyambanza, Emmanuel; Wesson, Jennifer; Tolley, Elizabeth E

    2014-10-15

    More than 40 million women use injectable contraceptives to prevent pregnancy, and most current or previous injectable users report being satisfied with the method. However, while women may find injectables acceptable, they may not always find them accessible due to stock-outs and difficulties with returning to the clinic for reinjections. FHI 360 is spearheading efforts to develop a longer-acting injectable (LAI) contraceptive that could provide at least 6 months of protection against pregnancy. This article addresses systems-level considerations for the introduction of a new LAI. We conducted qualitative case studies in Kenya and Rwanda-two countries that have high levels of injectable use but with different service delivery contexts. Between June and September 2012, we conducted in-depth interviews with 27 service providers and 19 policy makers and program implementers focusing on 4 themes: systems-level barriers and facilitators to delivering LAI services; process for introducing an LAI; LAI distribution approaches; and potential LAI characteristics. We also obtained electronic feedback from 28 international family planning opinion leaders. Respondents indicated strong interest in an LAI and thought it would appeal to existing injectable users as well as new family planning clients, both for spacing and for limiting births. Providers appreciated the potential for a lighter workload due to fewer follow-up visits, but they were concerned that fewer visits would also decrease their ability to help women manage side effects. The providers also appreciated the 1-month grace period for follow-up LAI injections; some seemed unaware of the latest international guidance that had increased the grace period from 2 weeks to 4 weeks for the currently available 3-month injectable. The majority of policy makers and program implementers were supportive of letting community health workers provide the method, but many nurses and midwives in Kenya had reservations about the approach. At the policy level, respondents indicated that obtaining regulatory approvals before introducing the new method could be costly and time-consuming. Manufacturing and procurement decisions could also affect cost and availability. Successful introduction of a potential longer-acting injectable may be enhanced by considering broader systemic issues, including managing cost to the health system and users, expanding access through community-based distribution, and training providers on the latest service delivery guidelines. © McKenna et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly cited. To view a copy of the license, visit http://creativecommons.org/licenses/by/3.0/. When linking to this article, please use the following permanent link: http://dx.doi.org/10.9745/GHSP-D-14-00106.

  20. Enhanced chemiluminescence of carminic acid-permanganate by CdS quantum dots and its application for sensitive quenchometric flow injection assays of cloxacillin.

    PubMed

    Khataee, Alireza; Hasanzadeh, Aliyeh; Lotfi, Roya; Joo, Sang Woo

    2016-05-15

    A novel chemiluminescence (CL) system is introduced based on the oxidation of carminic acid by KMnO4 in acidic conditions. CdS quantum dots (QDs) were synthesized using a facile hydrothermal method which efficiently enhanced the intensity of the CL system. A possible mechanism for the proposed system is presented using the kinetic curves, CL spectra, photoluminescence (PL), and ultraviolet-visible (UV-Vis) analysis. The emission intensity of the KMnO4-carminic acid-CdS QDs system was quenched in the presence of a trace level of cloxacillin. Based on this quenching effect, a novel and sensitive flow injection CL method was developed for determining cloxacillin concentrations. At optimal experimental conditions, the decreased CL intensity had a good linear relation with the cloxacillin concentration in the range of 0.008 to 22.0 mg L(-1). The detection limit (3σ) was 5.8 µg L(-1). The precision of the method was calculated by analyzing samples containing 4.0 mg L(-1) of cloxacillin (n=11), and the relative standard deviations (RSD%) were 2.08%. The feasibility of the method is also demonstrated for determining cloxacillin concentrations in environmental water samples and a pharmaceutical formulation. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Simultaneous Determination of Iron, Copper and Cobalt in Food Samples by CCD-diode Array Detection-Flow Injection Analysis with Partial Least Squares Calibration Model

    NASA Astrophysics Data System (ADS)

    Mi, Jiaping; Li, Yuanqian; Zhou, Xiaoli; Zheng, Bo; Zhou, Ying

    2006-01-01

    A flow injection-CCD diode array detection spectrophotometry with partial least squares (PLS) program for simultaneous determination of iron, copper and cobalt in food samples has been established. The method was based on the chromogenic reaction of the three metal ions and 2- (5-Bromo-2-pyridylazo)-5-diethylaminophenol, 5-Br-PADAP in acetic acid - sodium acetate buffer solution (pH5) with Triton X-100 and ascorbic acid. The overlapped spectra of the colored complexes were collected by charge-coupled device (CCD) - diode array detector and the multi-wavelength absorbance data was processed using partial least squares (PLS) algorithm. Optimum reaction conditions and parameters of flow injection analysis were investigated. The samples of tea, sesame, laver, millet, cornmeal, mung bean and soybean powder were determined by the proposed method. The average recoveries of spiked samples were 91.80%~100.9% for Iron, 92.50%~108.0% for Copper, 93.00%~110.5% for Cobalt, respectively with relative standard deviation (R.S.D) of 1.1%~12.1%. The sampling rate is 45 samples h-1. The determination results of the food samples were in good agreement between the proposed method and ICP-AES.

  2. Sequential injection system for simultaneous determination of sucrose and phosphate in cola drinks using paired emitter-detector diode sensor.

    PubMed

    Saetear, Phoonthawee; Khamtau, Kittiwut; Ratanawimarnwong, Nuanlaor; Sereenonchai, Kamonthip; Nacapricha, Duangjai

    2013-10-15

    This work presents the simultaneous determination of sucrose and phosphate by using sequential injection (SI) system with a low cost paired emitter-detector diode (PEDD) light sensor. The PEDD uses two 890 nm LEDs. Measurement of sucrose in Brix unit was carried out based on the detection of light refraction occurring at the liquid interface (the schlieren effect) between the sucrose solution and water. Phosphate was measured from the formation of calcium phosphate with turbidimetric detection. With careful design of the loading sequence and volume (sample--precipitating reagent--sample), simultaneous detection of sucrose and phosphate was accomplished with the single PEDD detector. At the optimized condition, linear calibrations from 1 to 7 Brix sucrose and from 50 to 200mg PO4(3-)L(-1) were obtained. Good precision at lower than 2% RSD (n=10) for both analytes with satisfactory throughput of 21 injections h(-1) was achieved. The method was successfully applied for the determination of sucrose and phosphate in cola drinks. The proposed method is readily applicable for automation and is found to be an alternative method to conventional procedures for on-line quality control process in cola drink industry. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  3. [Cell lineage tracing of regenerating cells after partial pancreatectomy using pseudo-type retrovirus].

    PubMed

    Zhang, Lixin; Ju, Xiaofang; Wang, Fa; Guo, Zhiwei; Piao, Shanhua; Teng, Chunbo

    2008-04-01

    Pancreas is an important mixed gland having both endocrine and exocrine functions, and has been proven regeneration after injury. To explore the cell lineage tracing methods in pancreas in vivo and the regenerate cells source, we used pseudo-type retrovirus to transfect adult mouse pancreas which had been partially pancreatectomized by rubbing the kerf using a cotton stick saturated with retrovirus suspension then injecting 100 microL retrovirus suspension into pancreas, injecting 100 microL retrovirus by caudal vein, or interperitoneally injecting retrovirus respectively. The results showed that the method of rubbing the kerf then injection of retrovirus suspension into pancreas could more effectively mark the pancreatic cells than the caudal vein injection and the intraperitoneal injection did in vivo. Furthermore, this study also found that some acinus cells could accept injury stimulus signals to regenerate through resuming mitosis after pancreatic injury. This study establishes a cell lineage tracing method in pancreas in vivo using retrovirus and offers a clue for gene therapy of pancreatic diseases using retrovirus vectors.

  4. Three-dimensional numerical simulation for plastic injection-compression molding

    NASA Astrophysics Data System (ADS)

    Zhang, Yun; Yu, Wenjie; Liang, Junjie; Lang, Jianlin; Li, Dequn

    2018-03-01

    Compared with conventional injection molding, injection-compression molding can mold optical parts with higher precision and lower flow residual stress. However, the melt flow process in a closed cavity becomes more complex because of the moving cavity boundary during compression and the nonlinear problems caused by non-Newtonian polymer melt. In this study, a 3D simulation method was developed for injection-compression molding. In this method, arbitrary Lagrangian- Eulerian was introduced to model the moving-boundary flow problem in the compression stage. The non-Newtonian characteristics and compressibility of the polymer melt were considered. The melt flow and pressure distribution in the cavity were investigated by using the proposed simulation method and compared with those of injection molding. Results reveal that the fountain flow effect becomes significant when the cavity thickness increases during compression. The back flow also plays an important role in the flow pattern and redistribution of cavity pressure. The discrepancy in pressures at different points along the flow path is complicated rather than monotonically decreased in injection molding.

  5. Development of a database and processing method for detecting hematotoxicity adverse drug events.

    PubMed

    Shimai, Yoshie; Takeda, Toshihiro; Manabe, Shirou; Teramoto, Kei; Mihara, Naoki; Matsumura, Yasushi

    2015-01-01

    Adverse events are detected by monitoring the patient's status, including blood test results. However, it is difficult to identify all adverse events based on recognition by individual doctors. We developed a system that can be used to detect hematotoxicity adverse events according to blood test results recorded in an electronic medical record system. The blood test results were graded based on Common Terminology Criteria for Adverse Events (CTCAE) and changes in the blood test results (Up, Down, Flat) were assessed according to the variation in the grade. The changes in the blood test and injection data were stored in a database. By comparing the date of injection and start and end dates of the change in the blood test results, adverse events related to a designated drug were detected. Using this method, we searched for the occurrence of serious adverse events (CTCAE Grades 3 or 4) concerning WBC, ALT and creatinine related to paclitaxel at Osaka University Hospital. The rate of occurrence of a decreased WBC count, increased ALT level and increased creatinine level was 36.0%, 0.6% and 0.4%, respectively. This method is useful for detecting and estimating the rate of occurrence of hematotoxicity adverse drug events.

  6. Comparison of microwave ablation, botulinum toxin injection, and liposuction-curettage in the treatment of axillary hyperhidrosis: A systematic review.

    PubMed

    Nasr, Marwan W; Jabbour, Samer F; Haber, Roger N; Kechichian, Elio G; El Hachem, Lena

    2017-02-01

    Primary focal axillary hyperhidrosis is a disorder of excessive sweating that can strongly impact quality of life. The objective if this study was to compare microwave ablation (MA), botulinum toxin (BT) injection, and liposuction-curettage (LC) in the treatment of primary axillary hyperhidrosis based on subjective and objective criteria. A systematic review of the literature published in French or English between 1 January 1991 and 1 February 2015 was completed using PubMed and Embase databases. 16 of 775 articles were selected based on relevance and criteria of inclusion and exclusion. The three methods proved to be efficient and safe; however, MA and BT had better results when compared to LC in the short term. Both MA and LC showed longer lasting results when compared to BT. However, in the long term, MA was superior to LC. MA, LC, and BT injections are safe and efficient minimally invasive alternatives for the treatment of axillary hyperhidrosis. Well-designed randomized controlled trials are needed to further compare the efficacy of these techniques.

  7. Determination of 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride by flow-injection analysis based on a specific condensation reaction between malonic acid and ethylenediamine.

    PubMed

    Seno, Kunihiko; Matumura, Kazuki; Oshita, Koji; Oshima, Mitsuko; Motomizu, Shoji

    2009-03-01

    A sensitive and rapid flow-injection analysis was developed for the determination of 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC.HCl), which was used for the formation of amide (peptide) and esters as a dehydration or condensation reagent. The EDC.HCl could be determined by the flow-injection analysis based on a specific condensation reaction between malonic acid and ethylenediamine in aquatic media. The reaction was accelerated at 60 degrees C, and the absorbance of the product was detected at 262 nm. The calibration graph of EDC.HCl showed good linearity in the range from 0 to 0.1% (0 to 0.0005 M), whose regression equation was y = 1.52 x 10(9)x (y, peak area; x, % concentration of EDC.HCl). The proposed method allowed high-throughput analysis; the sample throughput was 12 samples per hour. The limit of detection (LOD) and the relative standard deviation (RSD) were 2 x 10(-6) M and 1.0%, respectively. This reaction is proceeded in aqueous solution and specific for EDC.HCl.

  8. A laser syringe aimed at delivering drug into the outer layer of human skin

    NASA Astrophysics Data System (ADS)

    Yoh, Jack J.; Jang, Hun-jae; Park, Mi-ae; Han, Tae-hee; Hah, Jung-moo

    2012-07-01

    A desire to eliminate hypodermic needle in transdermal drug delivery may now be realized. Imaging of the skin after injection of fluorescent probe and biotin via the bio-ballistic technique revealed the epidermal and dermal layers which were stained well below 60 μm underneath the abdominal skin of the guinea-pig. An extensive network of cells are shown in the deeper layer of the stained dermis as the distributed fluorescein isothiocyanate (FITC) dose is administered by repeated injection via the laser-based microjet. Here, we show our method of laser-based microjet drug delivery is capable of breaching guinea-pig's skin tissue and then delivering controlled dose of drug to the targeted region between 10 to 400 μm underneath the outermost layer of the skin. While minimizing pain and tissue damage by reducing the injection volume to ˜100 nl per pulse and the microjet diameter of half the conventional syringe needle in 100 μm, the optimally controlled delivery of liquid drug by the irradiated laser pulse is shown possible.

  9. Experimental validation on the effect of material geometries and processing methodology of Polyoxymethylene (POM)

    NASA Astrophysics Data System (ADS)

    Hafizzal, Y.; Nurulhuda, A.; Izman, S.; Khadir, AZA

    2017-08-01

    POM-copolymer bond breaking leads to change depending with respect to processing methodology and material geometries. This paper present the oversights effect on the material integrity due to different geometries and processing methodology. Thermo-analytical methods with reference were used to examine the degradation of thermomechanical while Thermogravimetric Analysis (TGA) was used to judge the thermal stability of sample from its major decomposition temperature. Differential Scanning Calorimetry (DSC) investigation performed to identify the thermal behaviour and thermal properties of materials. The result shown that plastic gear geometries with injection molding at higher tonnage machine more stable thermally rather than resin geometries. Injection plastic gear geometries at low tonnage machine faced major decomposition temperatures at 313.61°C, 305.76 °C and 307.91 °C while higher tonnage processing method are fully decomposed at 890°C, significantly higher compared to low tonnage condition and resin geometries specimen at 398°C. Chemical composition of plastic gear geometries with injection molding at higher and lower tonnage are compare based on their moisture and Volatile Organic Compound (VOC) content, polymeric material content and the absence of filler. Results of higher moisture and Volatile Organic Compound (VOC) content are report in resin geometries (0.120%) compared to higher tonnage of injection plastic gear geometries which is 1.264%. The higher tonnage of injection plastic gear geometry are less sensitive to thermo-mechanical degradation due to polymer chain length and molecular weight of material properties such as tensile strength, flexural strength, fatigue strength and creep resistance.

  10. Ultra-low-dose Ultrasound Molecular Imaging for the Detection of Angiogenesis in a Mouse Murine Tumor Model: How Little Can We See?

    PubMed Central

    Wang, Shiying; Herbst, Elizabeth B.; Mauldin, F. William; Diakova, Galina B.; Klibanov, Alexander L.; Hossack, John A.

    2016-01-01

    Objectives The objective of this study is to evaluate the minimum microbubble dose for ultrasound molecular imaging to achieve statistically significant detection of angiogenesis in a mouse model. Materials and Methods The pre-burst minus post-burst method was implemented on a Verasonics ultrasound research scanner using a multi-frame compounding pulse inversion imaging sequence. Biotinylated lipid (distearoyl phosphatidylcholine, DSPC-based) microbubbles that were conjugated with anti-vascular endothelial growth factor 2 (VEGFR2) antibody (MBVEGFR2) or isotype control antibody (MBControl) were injected into mice carrying adenocarcinoma xenografts. Different injection doses ranging from 5 × 104 to 1 × 107 microbubbles per mouse were evaluated to determine the minimum diagnostically effective dose. Results The proposed imaging sequence was able to achieve statistically significant detection (p < 0.05, n = 5) of VEGFR2 in tumors with a minimum MBVEGFR2 injection dose of only 5 × 104 microbubbles per mouse (DSPC at 0.053 ng/g mouse body mass). Non-specific adhesion of MBControl at the same injection dose was negligible. Additionally, the targeted contrast ultrasound signal of MBVEGFR2 decreased with lower microbubble doses, while non-specific adhesion of MBControl increased with higher microbubble doses. Conclusions 5 × 104 microbubbles per animal is now the lowest injection dose on record for ultrasound molecular imaging to achieve statistically significant detection of molecular targets in vivo. Findings in this study provide us with further guidance for future developments of clinically translatable ultrasound molecular imaging applications using a lower dose of microbubbles. PMID:27654582

  11. A method for automatically optimizing medical devices for treating heart failure: designing polymeric injection patterns.

    PubMed

    Wenk, Jonathan F; Wall, Samuel T; Peterson, Robert C; Helgerson, Sam L; Sabbah, Hani N; Burger, Mike; Stander, Nielen; Ratcliffe, Mark B; Guccione, Julius M

    2009-12-01

    Heart failure continues to present a significant medical and economic burden throughout the developed world. Novel treatments involving the injection of polymeric materials into the myocardium of the failing left ventricle (LV) are currently being developed, which may reduce elevated myofiber stresses during the cardiac cycle and act to retard the progression of heart failure. A finite element (FE) simulation-based method was developed in this study that can automatically optimize the injection pattern of the polymeric "inclusions" according to a specific objective function, using commercially available software tools. The FE preprocessor TRUEGRID((R)) was used to create a parametric axisymmetric LV mesh matched to experimentally measured end-diastole and end-systole metrics from dogs with coronary microembolization-induced heart failure. Passive and active myocardial material properties were defined by a pseudo-elastic-strain energy function and a time-varying elastance model of active contraction, respectively, that were implemented in the FE software LS-DYNA. The companion optimization software LS-OPT was used to communicate directly with TRUEGRID((R)) to determine FE model parameters, such as defining the injection pattern and inclusion characteristics. The optimization resulted in an intuitive optimal injection pattern (i.e., the one with the greatest number of inclusions) when the objective function was weighted to minimize mean end-diastolic and end-systolic myofiber stress and ignore LV stroke volume. In contrast, the optimization resulted in a nonintuitive optimal pattern (i.e., 3 inclusions longitudinallyx6 inclusions circumferentially) when both myofiber stress and stroke volume were incorporated into the objective function with different weights.

  12. Critical review: Injectability of calcium phosphate pastes and cements.

    PubMed

    O'Neill, R; McCarthy, H O; Montufar, E B; Ginebra, M-P; Wilson, D I; Lennon, A; Dunne, N

    2017-03-01

    Calcium phosphate cements (CPC) have seen clinical success in many dental and orthopaedic applications in recent years. The properties of CPC essential for clinical success are reviewed in this article, which includes properties of the set cement (e.g. bioresorbability, biocompatibility, porosity and mechanical properties) and unset cement (e.g. setting time, cohesion, flow properties and ease of delivery to the surgical site). Emphasis is on the delivery of calcium phosphate (CaP) pastes and CPC, in particular the occurrence of separation of the liquid and solid components of the pastes and cements during injection; and established methods to reduce this phase separation. In addition a review of phase separation mechanisms observed during the extrusion of other biphasic paste systems and the theoretical models used to describe these mechanisms are discussed. Occurrence of phase separation of calcium phosphate pastes and cements during injection limits their full exploitation as a bone substitute in minimally invasive surgical applications. Due to lack of theoretical understanding of the phase separation mechanism(s), optimisation of an injectable CPC that satisfies clinical requirements has proven difficult. However, phase separation of pastes during delivery has been the focus across several research fields. Therefore in addition to a review of methods to reduce phase separation of CPC and the associated constraints, a review of phase separation mechanisms observed during extrusion of other pastes and the theoretical models used to describe these mechanisms is presented. It is anticipated this review will benefit future attempts to develop injectable calcium phosphate based systems. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  13. Guiding Intramuscular Diaphragm Injections Using Real-time Ultrasound & Electromyography

    PubMed Central

    Sarwal, Aarti; Cartwright, Michael S.; Mitchell, Erin; Williams, Koudy; Walker, Francis O.; Childers, Martin K.

    2014-01-01

    Introduction We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Methods Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. Results All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. Conclusions This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical electromyography of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. PMID:25354257

  14. Flow Injection Technique for Biochemical Analysis with Chemiluminescence Detection in Acidic Media

    PubMed Central

    Chen, Jing; Fang, Yanjun

    2007-01-01

    A review with 90 references is presented to show the development of acidic chemiluminescence methods for biochemical analysis by use of flow injection technique in the last 10 years. A brief discussion of both the chemiluminescence and flow injection technique is given. The proposed methods for biochemical analysis are described and compared according to the used chemiluminescence system.

  15. Fifteen-second skin icing using a frozen gel pack is effective for reducing goserelin injection pain.

    PubMed

    Naya, Yoshio; Hagiwara, Nobuhisa; Takeuchi, Ichiro; Mori, Masaru; Inagaki, Akinori; Nakanouchi, Tsuneyuki; Mikami, Kazuya

    2014-01-01

    The efficacy of skin icing to reduce the pain of goserelin injection has been reported. We investigated the optimal icing time with a frozen gel pack and its effectiveness. Abdominal skin temperatures of 49 healthy volunteers were measured after application of the frozen gel pack for 10, 15 and 30 s, and it was decided that a 15-second icing was adequate. For 55 consecutive patients who received goserelin (10.8 mg) injection, pain was evaluated employing a visual analog scale (VAS). The first injection was administered routinely. A second injection was administered after skin icing in 27 of 55 patients who wanted to try icing. At the time of the third injection, all patient decided whether they were to receive icing or the routine method. After icing, VAS scores decreased in 20 of 27 patients. At the third injection, 18 patients requested icing. When a patient complains of injection pain, the icing method should be considered for pain reduction. 2014 S. Karger AG, Basel.

  16. Method of controlling injection of oxygen into hydrogen-rich fuel cell feed stream

    DOEpatents

    Meltser, Mark Alexander; Gutowski, Stanley; Weisbrod, Kirk

    2001-01-01

    A method of operating a H.sub.2 --O.sub.2 fuel cell fueled by hydrogen-rich fuel stream containing CO. The CO content is reduced to acceptable levels by injecting oxygen into the fuel gas stream. The amount of oxygen injected is controlled in relation to the CO content of the fuel gas, by a control strategy that involves (a) determining the CO content of the fuel stream at a first injection rate, (b) increasing the O.sub.2 injection rate, (c) determining the CO content of the stream at the higher injection rate, (d) further increasing the O.sub.2 injection rate if the second measured CO content is lower than the first measured CO content or reducing the O.sub.2 injection rate if the second measured CO content is greater than the first measured CO content, and (e) repeating steps a-d as needed to optimize CO consumption and minimize H.sub.2 consumption.

  17. Tralokinumab pharmacokinetics and tolerability when administered by different subcutaneous injection methods and rates

    PubMed Central

    Jain, Meena; Doughty, Diane; Clawson, Corbin; Li, Xiaobai; White, Nicholas; Agoram, Balaji; van der Merwe, René

    2017-01-01

    Objective: Tralokinumab, administered as two 1-mL subcutaneous injections every 2 weeks, at the target dose 300 mg, has been shown to improve lung function in patients with asthma. This study evaluated the pharmacokinetic (PK) and tolerability profile of tralokinumab 300 mg when administered by different rates of subcutaneous injection, as part of a pilot investigation of new injection regimens. Methods: This phase I study randomized 60 healthy adults to receive 300 mg tralokinumab, as two 1-mL subcutaneous injections, each delivered over 10 seconds, or one 2-mL injection delivered over 10 seconds (12 mL/min), 1 minute (2 mL/min), or 12 minutes (0.167 mL/min). Results: No differences in the PK profile of tralokinumab were observed between cohorts. Immediately following injection, injection-site pain intensity (mean (SD)) was lowest following 0.167 mL/min injection (5.1 mm (8.0) via visual analog scale (VAS)) and greatest following 12 mL/min injection (41 mm (27.7) via VAS); with mean injection-site pruritus intensity low for all participants. Two types of local injection-site reactions were observed: erythema (58.3%) and hematoma/bleeding (18.3%). All treatment-emergent adverse events were mild. Conclusions: Tralokinumab 300 mg is well tolerated, with comparable PK, when administered by a single 2-mL injection at different rates of subcutaneous injection vs. two 1-mL injections. PMID:28590244

  18. Multiphase contrast medium injection for optimization of computed tomographic coronary angiography.

    PubMed

    Budoff, Matthew Jay; Shinbane, Jerold S; Child, Janis; Carson, Sivi; Chau, Alex; Liu, Stephen H; Mao, SongShou

    2006-02-01

    Electron beam angiography is a minimally invasive imaging technique. Adequate vascular opacification throughout the study remains a critical issue for image quality. We hypothesized that vascular image opacification and uniformity of vascular enhancement between slices can be improved using multiphase contrast medium injection protocols. We enrolled 244 consecutive patients who were randomized to three different injection protocols: single-phase contrast medium injection (Group 1), dual-phase contrast medium injection with each phase at a different injection rate (Group 2), and a three-phase injection with two phases of contrast medium injection followed by a saline injection phase (Group 3). Parameters measured were aortic opacification based on Hounsfield units and uniformity of aortic enhancement at predetermined slices (locations from top [level 1] to base [level 60]). In Group 1, contrast opacification differed across seven predetermined locations (scan levels: 1st versus 60th, P < .05), demonstrating significant nonuniformity. In Group 2, there was more uniform vascular enhancement, with no significant differences between the first 50 slices (P > .05). In Group 3, there was greater uniformity of vascular enhancement and higher mean Hounsfield units value across all 60 images, from the aortic root to the base of the heart (P < .05). The three-phase injection protocol improved vascular opacification at the base of the heart, as well as uniformity of arterial enhancement throughout the study.

  19. Comparison of two methods for selegiline determination: A flow-injection chemiluminescence method using cadmium sulfide quantum dots and corona discharge ion mobility spectrometry.

    PubMed

    Khataee, Alireza; Lotfi, Roya; Hasanzadeh, Aliyeh; Iranifam, Mortaza; Zarei, Mahmoud; Joo, Sang Woo

    2016-01-15

    Two analytical approaches including chemiluminescence (CL) and corona discharge ionization ion mobility spectrometry (CD-IMS) were developed for sensitive determination of selegiline (SG). We found that the CL intensity of the KMnO4-Na2S2O3 CL system was significantly enhanced in the presence of L-cysteine capped CdS quantum dots (QDs). A possible CL mechanism for this CL reaction is proposed. In the presence of SG, the enhanced CL system was inhibited. Based on this inhibition, a simple and sensitive flow-injection CL method was proposed for the determination of SG. Under optimum experimental conditions, the decreased CL intensity was proportional to SG concentration in the range of 0.01 to 30.0 mg L(-1). The detection limit (3σ) was 0.004 mg L(-1). Also, SG was determined using CD-IMS, and under optimum conditions of CD-IMS, calibration curves were linear in the range of 0.15 to 42.0 mg L(-1), with a detection limit (3σ) of 0.03 mg L(-1). The precision of the two methods was calculated by analyzing samples containing 5.0 mg L(-1) of SG (n=11). The relative standard deviations (RSDs%) of the flow-injection CL and CD-IMS methods are 2.17% and 3.83%, respectively. The proposed CL system exhibits a higher sensitivity and precision than the CD-IMS method for the determination of SG. Copyright © 2015. Published by Elsevier B.V.

  20. Cerebrospinal fluid dynamics study in communicating hydrocephalus

    PubMed Central

    Ramesh, Vengalathur Ganesan; Narasimhan, Vidhya; Balasubramanian, Chandramouli

    2017-01-01

    Context: Communicating hydrocephalus often poses a challenge in diagnosis and management decisions. Aims: The objective of this study is to measure the opening pressure (Po), pressure volume index (PVI), and cerebrospinal fluid outflow resistance (Rout), in patients with communicating hydrocephalus using bolus lumbar injection method and to evaluate its diagnostic and prognostic value. Materials and Methods: The study was conducted in 50 patients with communicating hydrocephalus, including normal pressure hydrocephalus (NPH) (19), post-meningitic hydrocephalus (23) and post-traumatic hydrocephalus (8). An improvised bolus lumbar injection method [the Madras Institute of Neurology (MIN) method] was used. Results: In the NPH Group, the CSF dynamics studies correlated well with the clinico-radiological classification. The prediction of shunt responsiveness by CSF dynamics studies correlated with good outcome in 87.5%. In the post-meningitic hydrocephalus group, the value of CSF dynamics studies in predicting patients needing shunt was 89.5%. The CSF dynamics studies detected patients who needed shunt earlier than clinical or radiological indications. In the post-traumatic hydrocephalus group, 62.5% of patients improved with the treatment based on CSF dynamics studies. Conclusions: The improvised bolus lumbar injection method (MIN method) is a very simple test with fairly reliable and reproducible results. Study of CSF dynamics is a valuable tool in communicating hydrocephalus for confirmation of diagnosis and predicting shunt responsiveness. This is the first time that the value of CSF dynamics has been studied in patients with post-meningitic hydrocephalus. It was also useful for early selection of cases for shunting and for identifying patients with atrophic ventriculomegaly, thereby avoiding unnecessary shunt. PMID:28484522

  1. Pregnancies associated with sperm concentrations below 10 million/ml in clinical studies of a potential male contraceptive method, monthly depot medroxyprogesterone acetate and testosterone esters.

    PubMed

    Barfield, A; Melo, J; Coutinho, E; Alvarez-Sanchez, F; Faundes, A; Brache, V; Leon, P; Frick, J; Bartsch, G; Weiske, W H; Brenner, P; Mishell, D; Bernstein, G; Ortiz, A

    1979-08-01

    A potential male contraceptive approach was evaluated in clinical trials involving monthly injections of depot medroxyprogesterone acetate and either subdermal implants of testosterone propionate or monthly injections of testosterone enanthate. Pregnancies occurred in partners of 9 men with recent sperm counts of 10 million/ml or below. In 5 of the 9 instances, the sperm counts were less than 1 million/ml. It appears that male contraceptive methods involving spermatogenic suppression may require attainment and maintenance of azoospermia. The pregnancy rate cannot be calculated, because the extent of other contraceptive use is uncertain. There were no spontaneous abortions. 6 pregnancies were carried to term, and all progeny were normal, based on physical examination at birth or 3 months after birth.

  2. A new simple screening method for the detection of paralytic shellfish poisoning toxins

    NASA Astrophysics Data System (ADS)

    Cheng, Jinping; Pi, Shuaishuai; Ye, Shufeng; Gao, Haomin; Yao, Lei; Jiang, Zhenyi; Song, Yuling; Xi, Lei

    2012-09-01

    The current testing for paralytic shellfish poisoning (PSP) in shellfish is based on the mouse bioassay (MBA). To alleviate animal welfare concerns, we evaluated the utility of using sublethal indicators of toxicity as an alternative to measuring time to death. Live mice were injected with a PSP congener and the changes in neurotransmitter levels were measured 60, 90, and 120 min after injection. Acetylcholine (ACh) was the most sensitive marker for PSP toxicity. The changes in neurotransmitter levels were most pronounced in the blood. Thus, measurement of Ach levels in the blood may serve as a sensitive predictor for PSP that would not require sacrifice of the mice. This method was relatively simple, sensitive (less than 1 μg/kg weight, equivalent to 20 ng/mL), low maintenance, and rapid (less than 60 min).

  3. Determination of formaldehyde in Romanian cosmetic products using coupled GC/MS system after SPME extraction

    NASA Astrophysics Data System (ADS)

    Feher, I.; Schmutzer, G.; Voica, C.; Moldovan, Z.

    2013-11-01

    In this study we have made a quick review of some Romanian cosmetic products (shampoo, conditioner, face wash) in order to determine the formaldehyde content as well as other substances called "formaldehyde releasers". The process was performed based on solid-phase microextraction (SPME) followed by gas chromatography/mass spectrometry technique. Prior to SPME extraction we used a derivation step of formaldehyde using pentafluorophenyl hydrazine. The obtained product was adsorbed on SPME devices, then injected and desorbed into the GC/MS injection port. The concentration of formaldehyde (as derived compound) was calculated using calibration curve, having a regression coefficient of 0.9938. The performance parameters of the method were calculated using samples of standard concentration. The method proved to be sensitive, having a quantification limit (LOQ) of 0.15 μg/g.

  4. Radiocarbon as a Reactive Tracer for Tracking Permanent CO 2 Storage in Basaltic Rocks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matter, Juerg; Stute, Martin; Schlosser, Peter

    In view of concerns about the long-term integrity and containment of CO 2 storage in geologic reservoirs, many efforts have been made to improve the monitoring, verification and accounting methods for geologically stored CO 2. Our project aimed to demonstrate that carbon-14 ( 14C) could be used as a reactive tracer to monitor geochemical reactions and evaluate the extent of mineral trapping of CO 2 in basaltic rocks. The capacity of a storage reservoir for mineral trapping of CO 2 is largely a function of host rock composition. Mineral carbonation involves combining CO 2 with divalent cations including Ca 2+,more » Mg 2+ and Fe 2+. The most abundant geological sources for these cations are basaltic rocks. Based on initial storage capacity estimates, we know that basalts have the necessary capacity to store million to billion tons of CO 2 via in situ mineral carbonation. However, little is known about CO2-fluid-rock reactions occurring in a basaltic storage reservoir during and post-CO 2 injection. None of the common monitoring and verification techniques have been able to provide a surveying tool for mineral trapping. The most direct method for quantitative monitoring and accounting involves the tagging of the injected CO 2 with 14C because 14C is not present in deep geologic reservoirs prior to injection. Accordingly, we conducted two CO 2 injection tests at the CarbFix pilot injection site in Iceland to study the feasibility of 14C as a reactive tracer for monitoring CO 2-fluid-rock reactions and CO 2 mineralization. Our newly developed monitoring techniques, using 14C as a reactive tracer, have been successfully demonstrated. For the first time, permanent and safe disposal of CO 2 as environmentally benign carbonate minerals in basaltic rocks could be shown. Over 95% of the injected CO 2 at the CarbFix pilot injection site was mineralized to carbonate minerals in less than two years after injection. Our monitoring results confirm that CO 2 mineralization in basaltic rocks is far faster than previously postulated.« less

  5. Flux amplification and sustainment of ST plasmas by multi-pulsed coaxial helicity injection on HIST

    NASA Astrophysics Data System (ADS)

    Higashi, T.; Ishihara, M.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.

    2010-11-01

    The Helicity Injected Spherical Torus (HIST) device has been developed towards high-current start up and sustainment by Multi-pulsed Coaxial Helicity Injection (M-CHI) method. Multiple pulses operation of the coaxial plasma gun can build the magnetic field of STs and spheromak plasmas in a stepwise manner. So far, successive gun pulses on SSPX at LLNL were demonstrated to maintain the magnetic field of spheromak in a quasi-steady state against resistive decay [1]. The resistive 3D-MHD numerical simulation [2] for STs reproduced the current amplification by the M-CHI method and confirmed that stochastic magnetic field was reduced during the decay phase. By double pulsed operation on HIST, the plasma current was effectively amplified against the resistive decay. The life time increases up to 10 ms which is longer than that in the single CHI case (4 ms). The edge poloidal fields last between 0.5 ms and 6 ms like a repetitive manner. During the second driven phase, the toroidal ion flow is driven in the same direction as the plasma current as well as in the initial driven phase. At the meeting, we will discuss a current amplification mechanism based on the merging process with the plasmoid injected secondly from the gun. [1] B. Hudson et al., Phys. Plasmas Vol.15, 056112 (2008). [2] Y. Kagei et al., J. Plasma Fusion Res. Vol.79, 217 (2003).

  6. A Noninvasive Method to Study Regulation of Extracellular ...

    EPA Pesticide Factsheets

    Time-domain nuclear magnetic resonance (TD-NMR)-based measurement of body composition of rodents is an effective method to quickly and repeatedly measure proportions of fat, lean, and fluid without anesthesia. TD-NMR provides a measure of free water in a living animal, termed % fluid, and is a measure of unbound water in the vascular and extracelular spaces. We hypothesized that injecting a bolus of fluid into the peritoneal cavity would lead to an abrupt increase in %fluid and the rate of clearance monitored with TD-NMR would provide a noninvasive assessment of the free water homeostasis in an awake rat. Several strains of laboratory rats were injected intraperitoneally with 10 ml/kg isotonic or hypertonic saline and % fluid was monitored repeatedly with a Bruker "Minispec" TD-NMR body composition system.Following isotonic saline, %fluid increased immediately by 0.5% followed by a recovery over ~6h. Injecting hypertonic (3 times normal saline) resulted in a significantly greater rise in %fluid and longer recovery. lntraperitoneal and subcutaneous fluid injection led to similar rates of clearance. The Wistar-Kyoto rat strain displayed significantly slower recovery to fluid loads compared with Long-Evans and Sprague-Dawley strains. Rats exercised chronically showed significant increases in %fluid, but the rate of clearance of fluid was similar to that of sedentary animals. We conclude that this technique could be used to study vascular and extracellular volume ho

  7. Electroluminescent devices formed using semiconductor nanocrystals as an electron transport media and method of making such electroluminescent devices

    DOEpatents

    Alivisatos, A. Paul; Colvin, Vickie

    1996-01-01

    An electroluminescent device is described, as well as a method of making same, wherein the device is characterized by a semiconductor nanocrystal electron transport layer capable of emitting visible light in response to a voltage applied to the device. The wavelength of the light emitted by the device may be changed by changing either the size or the type of semiconductor nanocrystals used in forming the electron transport layer. In a preferred embodiment the device is further characterized by the capability of emitting visible light of varying wavelengths in response to changes in the voltage applied to the device. The device comprises a hole processing structure capable of injecting and transporting holes, and usually comprising a hole injecting layer and a hole transporting layer; an electron transport layer in contact with the hole processing structure and comprising one or more layers of semiconductor nanocrystals; and an electron injecting layer in contact with the electron transport layer for injecting electrons into the electron transport layer. The capability of emitting visible light of various wavelengths is principally based on the variations in voltage applied thereto, but the type of semiconductor nanocrystals used and the size of the semiconductor nanocrystals in the layers of semiconductor nanometer crystals may also play a role in color change, in combination with the change in voltage.

  8. Flow injection chemiluminescence determination of the total phenolics levels in plant-derived beverages using soluble manganese(IV).

    PubMed

    Nalewajko-Sieliwoniuk, Edyta; Tarasewicz, Iwona; Kojło, Anatol

    2010-05-23

    This study established a flow injection (FI) methodology for the determination of the total phenolic content in plant-derived beverages based on soluble manganese(IV) chemiluminescence (CL) detection. It was found that mixing polyphenols with acidic soluble manganese(IV) in the presence of formaldehyde evoked chemiluminescence. Based on this finding, a new FI-CL method was developed for the estimation of the total content of phenolic compounds (expressed as milligrams of gallic acid equivalent per litre of drink) in a variety of wine, tea and fruit juice samples. The proposed method is sensitive with a detection limit of 0.02 ng mL(-1) (gallic acid), offers a wide linear dynamic range (0.5-400 ng mL(-1)) and high sample throughput (247 samples h(-1)). The relative standard deviation for 15 measurements was 3.8% for 2 ng mL(-1) and 0.45% for 10 ng mL(-1) of gallic acid. Analysis of 36 different samples showed that the results obtained by the proposed FI-CL method correlate highly with those obtained by spectrophotometric methods commonly used for the evaluation of the total phenolic/antioxidant level. However, the FI-CL method was found to be far simpler, more rapid and selective, with almost no interference from non-phenolic components of the samples examined. Copyright 2010 Elsevier B.V. All rights reserved.

  9. Image counter-forensics based on feature injection

    NASA Astrophysics Data System (ADS)

    Iuliani, M.; Rossetto, S.; Bianchi, T.; De Rosa, Alessia; Piva, A.; Barni, M.

    2014-02-01

    Starting from the concept that many image forensic tools are based on the detection of some features revealing a particular aspect of the history of an image, in this work we model the counter-forensic attack as the injection of a specific fake feature pointing to the same history of an authentic reference image. We propose a general attack strategy that does not rely on a specific detector structure. Given a source image x and a target image y, the adversary processes x in the pixel domain producing an attacked image ~x, perceptually similar to x, whose feature f(~x) is as close as possible to f(y) computed on y. Our proposed counter-forensic attack consists in the constrained minimization of the feature distance Φ(z) =│ f(z) - f(y)│ through iterative methods based on gradient descent. To solve the intrinsic limit due to the numerical estimation of the gradient on large images, we propose the application of a feature decomposition process, that allows the problem to be reduced into many subproblems on the blocks the image is partitioned into. The proposed strategy has been tested by attacking three different features and its performance has been compared to state-of-the-art counter-forensic methods.

  10. A Semi-Analytical Method for Rapid Estimation of Near-Well Saturation, Temperature, Pressure and Stress in Non-Isothermal CO2 Injection

    NASA Astrophysics Data System (ADS)

    LaForce, T.; Ennis-King, J.; Paterson, L.

    2015-12-01

    Reservoir cooling near the wellbore is expected when fluids are injected into a reservoir or aquifer in CO2 storage, enhanced oil or gas recovery, enhanced geothermal systems, and water injection for disposal. Ignoring thermal effects near the well can lead to under-prediction of changes in reservoir pressure and stress due to competition between increased pressure and contraction of the rock in the cooled near-well region. In this work a previously developed semi-analytical model for immiscible, nonisothermal fluid injection is generalised to include partitioning of components between two phases. Advection-dominated radial flow is assumed so that the coupled two-phase flow and thermal conservation laws can be solved analytically. The temperature and saturation profiles are used to find the increase in reservoir pressure, tangential, and radial stress near the wellbore in a semi-analytical, forward-coupled model. Saturation, temperature, pressure, and stress profiles are found for parameters representative of several CO2 storage demonstration projects around the world. General results on maximum injection rates vs depth for common reservoir parameters are also presented. Prior to drilling an injection well there is often little information about the properties that will determine the injection rate that can be achieved without exceeding fracture pressure, yet injection rate and pressure are key parameters in well design and placement decisions. Analytical solutions to simplified models such as these can quickly provide order of magnitude estimates for flow and stress near the well based on a range of likely parameters.

  11. Determining the best treatment for simple bone cyst: a decision analysis.

    PubMed

    Lee, Seung Yeol; Chung, Chin Youb; Lee, Kyoung Min; Sung, Ki Hyuk; Won, Sung Hun; Choi, In Ho; Cho, Tae-Joon; Yoo, Won Joon; Yeo, Ji Hyun; Park, Moon Seok

    2014-03-01

    The treatment of simple bone cysts (SBC) in children varies significantly among physicians. This study examined which procedure is better for the treatment of SBC, using a decision analysis based on current published evidence. A decision tree focused on five treatment modalities of SBC (observation, steroid injection, autologous bone marrow injection, decompression, and curettage with bone graft) were created. Each treatment modality was further branched, according to the presence and severity of complications. The probabilities of all cases were obtained by literature review. A roll back tool was utilized to determine the most preferred treatment modality. One-way sensitivity analysis was performed to determine the threshold value of the treatment modalities. Two-way sensitivity analysis was utilized to examine the joint impact of changes in probabilities of two parameters. The decision model favored autologous bone marrow injection. The expected value of autologous bone marrow injection was 0.9445, while those of observation, steroid injection, decompression, and curettage and bone graft were 0.9318, 0.9400, 0.9395, and 0.9342, respectively. One-way sensitivity analysis showed that autologous bone marrow injection was better than that of decompression for the expected value when the rate of pathologic fracture, or positive symptoms of SBC after autologous bone marrow injection, was lower than 20.4%. In our study, autologous bone marrow injection was found to be the best choice of treatment of SBC. However, the results were sensitive to the rate of pathologic fracture after treatment of SBC. Physicians should consider the possibility of pathologic fracture when they determine a treatment method for SBC.

  12. Experimental feasibility study of radial injection cooling of three-pad radial air foil bearings

    NASA Astrophysics Data System (ADS)

    Shrestha, Suman K.

    Air foil bearings use ambient air as a lubricant allowing environment-friendly operation. When they are designed, installed, and operated properly, air foil bearings are very cost effective and reliable solution to oil-free turbomachinery. Because air is used as a lubricant, there are no mechanical contacts between the rotor and bearings and when the rotor is lifted off the bearing, near frictionless quiet operation is possible. However, due to the high speed operation, thermal management is one of the very important design factors to consider. Most widely accepted practice of the cooling method is axial cooling, which uses cooling air passing through heat exchange channels formed underneath the bearing pad. Advantage is no hardware modification to implement the axial cooling because elastic foundation structure of foil bearing serves as a heat exchange channels. Disadvantage is axial temperature gradient on the journal shaft and bearing. This work presents the experimental feasibility study of alternative cooling method using radial injection of cooling air directly on the rotor shaft. The injection speeds, number of nozzles, location of nozzles, total air flow rate are important factors determining the effectiveness of the radial injection cooling method. Effectiveness of the radial injection cooling was compared with traditional axial cooling method. A previously constructed test rig was modified to accommodate a new motor with higher torque and radial injection cooling. The radial injection cooling utilizes the direct air injection to the inlet region of air film from three locations at 120° from one another with each location having three axially separated holes. In axial cooling, a certain axial pressure gradient is applied across the bearing to induce axial cooling air through bump foil channels. For the comparison of the two methods, the same amount of cooling air flow rate was used for both axial cooling and radial injection. Cooling air flow rate was referenced to the rotor surface speed for radial injection cooling. The mass flow rates for the radial injection were 0.032, 0.0432, 0.054 and 0.068 Kg/min, which result in average injection speed of 150, 200, 250 and 300% of rotor surface speed. Several thermocouples were attached at various circumferential directions of the bearing sleeve, two plenums, bearing holder and ball bearing housings to collect the temperature data of the bearing at 30krpm under 10lb of load. Both axial cooling and radial injection are effective cooling mechanism and effectiveness of both cooling methods is directly proportional to the total mass flow rates. However, axial cooling is slightly more efficient in controlling the average temperature of the bearing sleeve, but results in higher thermal gradient of the shaft along the axial direction and also higher thermal gradient of the bearing sleeve along the circumferential direction compared to the radial injection cooling. The smaller thermal gradient of the radial injection cooling is due to the direct cooling effect of the shaft by impinging jets. While the axial cooling has an effect on only the bearing, the radial injection has a cooling effect on both the bearing sleeve and shaft. It is considered the radial injection cooling needs to be further optimized in terms of number of injection holes and their locations.

  13. Dermal Filler Injection: A Novel Approach for Limiting Infarct Expansion

    PubMed Central

    Ryan, Liam P.; Matsuzaki, Kanji; Noma, Mio; Jackson, Benjamin M.; Eperjesi, Thomas J.; Plappert, Theodore J.; St. John-Sutton, Martin G.; Gorman, Joseph H.; Gorman, Robert C.

    2011-01-01

    Background Early infarct expansion after coronary occlusion compromises contractile function in perfused myocardial regions and promotes adverse long-term left ventricular (LV) remodeling. We hypothesized that injection of a tissue-expanding dermal filler material into a myocardial infarction (MI) would attenuate infarct expansion and limit LV remodeling. Methods Fifteen sheep were subjected to an anteroapical MI involving approximately 20% of the LV followed by the injection of 1.3 mL of a calcium hydroxyapatite–based dermal filler into the infarct. Real-time three-dimensional echocardiography was performed at baseline, 30 minutes after MI, and 15 minutes after injection to assess infarct expansion. Sixteen additional sheep were subjected to the same infarction and followed echocardiographically and hemodynamically for 4 weeks after MI to assess chronic remodeling. Eight animals had injection with dermal filler as described above immediately after MI, and 8 animals were injected with an equal amount of saline solution. Results All animals exhibited infarct expansion soon after coronary occlusion. The regional ejection fraction of the apex became negative after infarction, consistent with systolic dyskinesia. Injection of the dermal filler converted the apical wall motion from dyskinetic to akinetic and resulted immediately in significant decreases in global, regional, and segmental LV volumes. Chronically, relative to saline control, dermal filler injection significantly reduced LV end-systolic volume (62.2 ± 3.6 mL versus 44.5 ± 3.9 mL; p < 0.05) and improved global ejection fraction (0.295 ± 0.016 versus 0.373 ± 0.017; p < 0.05) at 4 weeks after infarction. Conclusions Injection of an acellular dermal filler into an MI immediately after coronary occlusion reduces early infarct expansion and limits chronic LV remodeling. PMID:19101288

  14. Application of Local Injection of Botulinum Toxin A in Cosmetic Patients with Congenital Drooping Mouth Corner.

    PubMed

    Qian, Wei; Zhang, Yan-Kun; Lv, Wei; Hou, Ying; Cao, Qian; Fan, Ju-Feng

    2016-12-01

    This study aimed to investigate the clinical application and efficacy of local injection of botulinum toxin A (BTX-A) at the depressor anguli oris in patients with congenital drooping mouth corner. From September 2013 to March 2015, 36 cosmetic patients received local injections of botulinum toxin A at the depressor anguli oris, with 1-3 injection sites in the moving region of the depressor anguli oris on each side. At each injection site, 2-4 U of BTX-A was injected, and the total dose for any unilateral treatment did not exceed 8 U. The change in the degree of drooping of the mouth corner before and after the injection was analyzed using statistical methods. The clinical efficacy, preservation time, and adverse reactions were observed. The degree of drooping of the mouth corners of the cosmetic patients before the treatment was compared with that at 1 month after using a paired t test, and the difference was statistically significant, with P < 0.01. The treatment results were satisfactory, and the effect was preserved for 6-9 months. None of the 36 cosmetic patients had any complications of bruising, infection, dysfunction in opening and closing the mouth, smile asymmetry, drooling, or dysarthria after the injection. The local injection of BTX-A at the depressor anguli oris can effectively lift a drooping mouth corner, thereby improving the depressed, stern, and aged appearance of the face. The performance of this treatment is simple, safe, and easy to perform in clinical applications. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  15. Bladder base/trigone injection is safe and as effective as bladder body injection of onabotulinumtoxinA for idiopathic detrusor overactivity refractory to antimuscarinics.

    PubMed

    Kuo, Hann-Chorng

    2011-09-01

    The purpose of this study was to evaluate the efficacy and safety of onabotulinumtoxinA injections at bladder base/trigone and compare with injections at bladder body or bladder body/trigone for the treatment of idiopathic detrusor overactivity (IDO) refractory to antimuscarinics. A single blind, randomized, paralleled, actively controlled trial was performed in patients with urodynamically proven IDO who failed antimuscarinic therapy. Patients were randomly assigned to receive intravesical injections of 100 U of onabotulinumtoxinA into three different bladder sites. All treatments were evaluated by voiding diary variables, urgency severity score, urodynamic studies, and patient perception of bladder condition. Long-term success rates over 12 months were also determined. Among the patients, 37 were randomized to injections in the bladder body, 35 into the bladder body/trigone, and 33 into the bladder base/trigone. Successful results were reported in 76 (72%) patients at 3 months: 26 (70%) in the bladder body group, 26 (74%) in the bladder body/trigone group, and 24 (73%) in the bladder base/trigone group. There were no significant differences in success rates, changes in urgency and urgency incontinence episodes, urodynamic variables, or long-term success rates among the three subgroups. The incidence of adverse events was similar among three groups. No vesicoureteral reflux was noted in all patients with or without involving trigone injection. Intravesical onabotulinumtoxinA injection is an effective treatment for IDO regardless of the bladder injection site. Bladder base/trigone injection is as safe and effective as bladder body injections with or without trigone involvement. Copyright © 2011 Wiley-Liss, Inc.

  16. Vaccination of carp against SVCV with an oral DNA vaccine or an insect cells-based subunit vaccine.

    PubMed

    Embregts, C W E; Rigaudeau, D; Tacchi, L; Pijlman, G P; Kampers, L; Veselý, T; Pokorová, D; Boudinot, P; Wiegertjes, G F; Forlenza, M

    2018-03-19

    We recently reported on a successful vaccine for carp against SVCV based on the intramuscular injection of a DNA plasmid encoding the SVCV glycoprotein (SVCV-G). This shows that the intramuscular (i.m.) route of vaccination is suitable to trigger protective responses against SVCV, and that the SVCV G-protein is a suitable vaccine antigen. Yet, despite the general success of DNA vaccines, especially against fish rhabdoviruses, their practical implementation still faces legislative as well as consumer's acceptance concerns. Furthermore, the i.m. route of plasmid administration is not easily combined with most of the current vaccination regimes largely based on intraperitoneal or immersion vaccination. For this reason, in the current study we evaluated possible alternatives to a DNA-based i.m. injectable vaccine using the SVCV-G protein as the vaccine antigen. To this end, we tested two parallel approaches: the first based on the optimization of an alginate encapsulation method for oral delivery of DNA and protein antigens; the second based on the baculovirus recombinant expression of transmembrane SVCV-G protein in insect cells, administered as whole-cell subunit vaccine through the oral and injection route. In addition, in the case of the oral DNA vaccine, we also investigated the potential benefits of the mucosal adjuvants Escherichia coli lymphotoxin subunit B (LTB). Despite the use of various vaccine types, doses, regimes, and administration routes, no protection was observed, contrary to the full protection obtained with our reference i.m. DNA vaccine. The limited protection observed under the various conditions used in this study, the nature of the host, of the pathogen, the type of vaccine and encapsulation method, will therefore be discussed in details to provide an outlook for future vaccination strategies against SVCV. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. The network approach and interventions to prevent HIV among injection drug users.

    PubMed Central

    Neaigus, A

    1998-01-01

    OBJECTIVE: To review human immunodeficiency virus (HIV) risk reduction interventions among injecting drug users (IDUs) that have adopted a network approach. METHODS: The design and outcomes of selected network-based interventions among IDUs are reviewed using the network concepts of the dyad (two-person relationship), the personal risk network (an index person and all of his or her relationship), and the "sociometric" network (the complete set of relations between people in a population) and community. RESULTS: In a dyad intervention among HIV-serodiscordant couples, many of which included IDUs, there were no HIV seroconversions. Participants in personal risk network interventions were more likely to reduce drug risks and in some of these interventions, sexual risks, than were participants in individual-based interventions. Sociometric network interventions reached more IDUs and may be more cost-effective than individual-based interventions. CONCLUSION: Network-based HIV risk reduction interventions among IDUs, and others at risk for HIV, hold promise and should be encouraged. PMID:9722819

  18. Three-Year Analysis of Value and Utilization After Development of an Ultrasound-Based Orthopedic Injection Clinic.

    PubMed

    Dukes, Chase; Melton, Thomas; Turner, Eric; Jackson, Andrew; Grassbaugh, Jason; Slevin, John; Arrington, Edward D; Eichinger, Josef K

    2017-09-01

    Sonography is an effective method of diagnosing and treating musculoskeletal conditions, and the use of ultrasound has been shown to improve the accuracy, safety, and efficacy of both therapeutic and diagnostic injections. In 2012, we established an injection clinic at our institution to address our growing need for diagnostic and therapeutic injections. We performed an analysis of value and utilization following the development of an orthopedic injection clinic. This included an evaluation of the cost of materials, equipment, and training required to develop and run the clinic, and an analysis of the services rendered and relative value units (RVUs) generated over 3 fiscal years (FYs). The cost to develop the clinic was $42,498.30. The cost to run the clinic thereafter was $16.90 to $21.60 per injection. By the end of FY 2012, 60% of providers performed at least 1 injection under ultrasound guidance. Every successive year thereafter, 100% of providers were using ultrasound guidance. In FY 2012, we performed 738 injections, 5.4% used ultrasound guidance and generated a total of 1,786.36 RVUs. In FY 2013, we performed 1,814 injections, 17.6% used ultrasound guidance, and generated a total of 7,224.5 RVUs. In FY 2014, we performed 2,821 injections, 25.2% used ultrasound guidance, and generated 13,786.82 RVUs. RVUs generated solely from ultrasound guided injections were 463.2 (2012), 3,694 (2013), 8,221.8 (2014). Injection accuracy was at least 98%. Average time until injection was 0 days. The cost to start an injection clinic is modest, with the potential for large annual growth and early return on investment, and can generate significant revenue by recapturing RVUs that would otherwise be lost to outside referrals. Furthermore, it helps to increase clinic throughput, maximize services rendered during a single patient visit improving the overall quality of their encounter, expands the clinical practice of our midlevel providers, offloads clinical time for surgical providers, and can help expedite clinical decision making. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  19. Comparative effectiveness of intra-articular prolotherapy versus peri-articular prolotherapy on pain reduction and improving function in patients with knee osteoarthritis: A randomized clinical trial.

    PubMed

    Farpour, Hamid Reza; Fereydooni, Farzane

    2017-11-01

    Osteoarthritis is a common degenerative disease. Prolotherapy is an alternative therapy used in multiple musculoskeletal disorders. To compare the effectiveness of intra-articular dextrose injection versus peri-articular prolotherapy in patients with knee osteoarthritis (KOA). Fifty-two adults with painful primary knee osteoarthritis for at least three months were randomized to intra- and peri-articular injection groups. Prolotherapy was done twice with two week intervals. The outcome measures included the Oxford Knee Scale (OKS), Western Ontario McMaster University Osteoarthritis Index (WOMAC), and Visual Analogue Scale (VAS), which were obtained from patients before the first injection at the base line and after the second injection at the fourth and eighth weeks. There were no statistically significant differences between demographic characteristics; before the injection, pain intensity, OKS, and WOMAC scores were approximately equal between the two groups. After dextrose prolotherapy, VAS, OKS, and WOMAC scores improved from baseline through the fourth and eighth weeks in both groups without any superiority between the two methods of injections (p<0.001). Dextrose prolotherapy either intra- or peri-articular injection resulted in significant improvement, so it could be an inexpensive and effective management of knee osteoarthritis. The study protocol was registered as a clinical trial under registration ID of IRCT2016091229795N1 at the Iranian Registry of Clinical Trials (http://www.irct.ir). The authors received no financial support for the research, authorship, or publication of this article.

  20. High resolution 3D MRI of mouse mammary glands with intra-ductal injection of contrast media

    PubMed Central

    Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Roman, Brian B.; Jansen, Sanaz A.; Macleod, Kay; Conzen, Suzanne D.; Karczmar, Gregory S.

    2014-01-01

    The purpose of this study was to use high resolution 3D MRI to study mouse mammary gland ductal architecture based on intra-ductal injection of contrast agents. Female FVB/N mice age 12–20 weeks (n = 12), were used in this study. A 34G, 45° tip Hamilton needle with a 25uL Hamilton syringe was inserted into the tip of the nipple. Approximately 20–25uL of a Gadodiamide/Trypan blue/saline solution was injected slowly over one minute into the nipple and duct. To prevent washout of contrast media from ducts due to perfusion, and maximize the conspicuity of ducts on MRI, mice were sacrificed one minute after injection. High resolution 3D T1-weighted images were acquired on a 9.4T Bruker scanner after sacrifice to eliminate motion artifacts and reduce contrast media leakage from ducts. Trypan blue staining was well distributed throughout the ductal tree. MRI showed the mammary gland ductal structure clearly. In spoiled gradient echo T1-weighted images, the signal-to-noise ratio of regions identified as enhancing mammary ducts following contrast injection was significantly higher than that of muscle (p < 0.02) and significantly higher than that of contralateral mammary ducts that were not injected with contrast media (p < 0.0001). The methods described here could be adapted for injection of specialized contrast agents to measure metabolism or target receptors in normal ducts and ducts with in situ cancers. PMID:25179139

  1. Wideband-frequency tunable optoelectronic oscillator based on injection locking to an electronic oscillator.

    PubMed

    Fleyer, Michael; Sherman, Alexander; Horowitz, Moshe; Namer, Moshe

    2016-05-01

    We experimentally demonstrate a wideband-frequency tunable optoelectronic oscillator (OEO) based on injection locking of the OEO to a tunable electronic oscillator. The OEO cavity does not contain a narrowband filter and its frequency can be tuned over a broad bandwidth of 1 GHz. The injection locking is based on minimizing the injected power by adjusting the frequency of one of the OEO cavity modes to be approximately equal to the frequency of the injected signal. The phase noise that is obtained in the injection-locked OEO is similar to that obtained in a long-cavity self-sustained OEO. Although the cavity length of the OEO was long, the spurious modes were suppressed due to the injection locking without the need to use a narrowband filter. The spurious level was significantly below that obtained in a self-sustained OEO after inserting a narrowband electronic filter with a Q-factor of 720 into the cavity.

  2. Development of a statistically proven injection molding method for reaction bonded silicon nitride, sintering reaction bonded silicon nitride, and sintered silicon nitride

    NASA Astrophysics Data System (ADS)

    Steiner, Matthias

    A statistically proven, series injection molding technique for ceramic components was developed for the construction of engines and gas turbines. The flow behavior of silicon injection-molding materials was characterized and improved. Hot-isostatic-pressing reaction bonded silicon nitride (HIPRBSN) was developed. A nondestructive component evaluation method was developed. An injection molding line for HIPRBSN engine components precombustion chamber, flame spreader, and valve guide was developed. This line allows the production of small series for engine tests.

  3. Intradermal needle-free powdered drug injection by a helium-powered device.

    PubMed

    Liu, John; Hogan, N Catherine; Hunter, Ian W

    2012-01-01

    We present a new method for needle-free powdered drug injection via a bench-top gas-powered device. This injector provides an alternative method of vaccine delivery to address the cold chain problem--the cost and risk of transporting temperature sensitive vaccines to developing countries. The device houses interchangeable nozzle inserts to vary orifice geometries and is capable of delivering polymer beads (1-5 µm diameter) into the dermal layer of porcine tissue. Results for injection shape and injection depth versus nozzle orifice diameter demonstrate the device's controllability.

  4. Efficacy of ivermectin in injectable and oral paste formulations against eight-week-old Strongylus vulgaris larvae in ponies.

    PubMed

    Klei, T R; Torbert, B J; Chapman, M R; Turk, M A

    1984-01-01

    A controlled test method was used to evaluate the efficacy of injectable micelle and oral paste formulations of ivermectin (22,23-dihydroavermectin B1) against 8-week-old Strongylus vulgaris larvae in experimentally infected pony foals. The dosage level of the drug in both formulations tested was 0.2 mg/kg. Ponies were euthanatized and necropsied 5 weeks after treatment. Based on the recovery of live vs dead S vulgaris from mesenteric arteries, both formulations were greater than 99% effective. Increased weight gains and marked reductions in the severity of arterial lesions were observed in treated ponies.

  5. Method and system for control of upstream flowfields of vehicle in supersonic or hypersonic atmospheric flight

    NASA Technical Reports Server (NTRS)

    Daso, Endwell O. (Inventor); Pritchett, II, Victor E. (Inventor); Wang, Ten-See (Inventor); Farr, Rebecca Ann (Inventor)

    2012-01-01

    The upstream flowfield of a vehicle traveling in supersonic or hypersonic atmospheric flight is actively controlled using attribute(s) experienced by the vehicle. Sensed attribute(s) include pressure along the vehicle's outer mold line, temperature along the vehicle's outer mold line, heat flux along the vehicle's outer mold line, and/or local acceleration response of the vehicle. A non-heated, non-plasma-producing gas is injected into an upstream flowfield of the vehicle from at least one surface location along the vehicle's outer mold line. The pressure of the gas so-injected is adjusted based on the attribute(s) so-sensed.

  6. A portable battery-powered flow injection monitor for the in situ analysis of nitrate in natural waters

    PubMed Central

    Blundell, N. J.; Hopkins, A.; Worsfold, P. J.; Casey, H.

    1993-01-01

    The design and performance of a portable, automated flow injection (FI)-based photometric monitor are described. The system is controlled by an in-house microcomputer system that enables the monitor (including a solid state detector) to operate from a 12 V battery supply. The monitor uses the cadmium reduction/diazotization method to analyse for nitrate with a linear range of 0 to 12 mg l-1 and a limit of detection of 0.05 mg l-1 (NO3-N). The hardware and software design, monitor performance and results obtained during unattended operation are presented. PMID:18924971

  7. PNEUMATIC MICROVALVE FOR ELECTROKINETIC SAMPLE PRECONCENTRATION AND CAPILLARY ELECTROPHORESIS INJECTION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cong, Yongzheng; Rausch, Sarah J.; Geng, Tao

    2014-10-27

    Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefly opened and the sample is hydrodynamically injected onto an integrated microchip or capillary electrophoresis (CE) column. In contrast to existing preconcentration approaches, the membrane-based method described here enables both rapid analyte concentration as well as highmore » resolution separations.« less

  8. Evaluation of injection methods for fast, high peak capacity separations with low thermal mass gas chromatography.

    PubMed

    Fitz, Brian D; Mannion, Brandyn C; To, Khang; Hoac, Trinh; Synovec, Robert E

    2015-05-01

    Low thermal mass gas chromatography (LTM-GC) was evaluated for rapid, high peak capacity separations with three injection methods: liquid, headspace solid phase micro-extraction (HS-SPME), and direct vapor. An Agilent LTM equipped with a short microbore capillary column was operated at a column heating rate of 250 °C/min to produce a 60s separation. Two sets of experiments were conducted in parallel to characterize the instrumental platform. First, the three injection methods were performed in conjunction with in-house built high-speed cryo-focusing injection (HSCFI) to cryogenically trap and re-inject the analytes onto the LTM-GC column in a narrower band. Next, the three injection methods were performed natively with LTM-GC. Using HSCFI, the peak capacity of a separation of 50 nl of a 73 component liquid test mixture was 270, which was 23% higher than without HSCFI. Similar peak capacity gains were obtained when using the HSCFI with HS-SPME (25%), and even greater with vapor injection (56%). For the 100 μl vapor sample injected without HSCFI, the preconcentration factor, defined as the ratio of the maximum concentration of the detected analyte peak relative to the analyte concentration injected with the syringe, was determined to be 11 for the earliest eluting peak (most volatile analyte). In contrast, the preconcentration factor for the earliest eluting peak using HSCFI was 103. Therefore, LTM-GC is demonstrated to natively provide in situ analyte trapping, although not to as great an extent as with HSCFI. We also report the use of LTM-GC applied with time-of-flight mass spectrometry (TOFMS) detection for rapid, high peak capacity separations from SPME sampled banana peel headspace. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Outreach-based HIV prevention for injecting drug users: a review of published outcome data.

    PubMed Central

    Coyle, S L; Needle, R H; Normand, J

    1998-01-01

    OBJECTIVE: Over the past decade, a body of observational research has accrued about the effects of outreach-based human immunodeficiency virus (HIV) interventions for drug users. The authors reviewed the findings related to postintervention behavior changes and integrated findings across studies to provide the best estimate of program impact. METHODS: The authors conducted a computerized literature search to locate published accounts of HIV intervention effects on drug users. Thirty-six publications covered outreach-based HIV risk reduction interventions for out-of-treatment injecting drug users (IDUs) and reported intervention effects on HIV-related behaviors or HIV seroincidence. Two-thirds of the publications reported that participation in street-based outreach interventions was followed with office-based HIV testing and counseling. The authors described the theoretical underpinnings of outreach intervention components, the content of the interventions, and the outcome measures that investigators used most frequently. The authors also described and critiqued the evaluation study designs that were in place. Because most of the evaluations were based on pretest and posttest measures of behavior rather than on controlled studies, results were examined with respect to accepted criteria for attributing intervention causality, that is, the plausibility of cause and effect, correct temporal sequence, consistency of findings across reports, strength of associations observed, specifically of associations, and dose-response relationships between interventions and observed outcomes. RESULTS: The majority of the published evaluations showed that IDUs in a variety of places and time periods changed their baseline drug-related and sex-related risk behaviors following their participation in a outreach-based HIV risk reduction intervention. More specifically, the publications indicated that IDUs regularly reported significant follow-up reductions in drug injection, multiperson reuse of syringes and needles, multiperson reuse of other injection equipment (cookers, cotton, rinse water), and crack use. The studies also showed significant intervention effects in promoting entry into drug treatment and increasing needle disinfection. Although drug users also significantly reduced sex-related risks and increased condom use, the majority still practiced unsafe sex. One quasi-experimental study found that reductions in injection risk led to significantly reduced HIV seroincidence among outreach participants. Few investigators looked at dosage effects, but two reports suggested that the longer the exposure to outreach-based interventions, the greater the reductions in drug injection frequency. CONCLUSIONS: Accumulated evidence from observational and quasi-experimental studies strongly indicate that outreach-based interventions have been effective in reaching out-of-treatment IDUs, providing the means for behavior changes and inducing behavior change in the desired direction. The findings provide sound evidence that participation in outreach-based prevention programs can lead to lower HIV incidence rates among program participants. PMID:9722807

  10. Production of recombinant Bombyx mori nucleopolyhedrovirus in silkworm by intrahaemocoelic injection with invasive diaminopimelate auxotrophic Escherichia coli containing BmNPV-Bacmid.

    PubMed

    Sun, Jingchen; Yao, Lunguang; Yao, Ning; Xu, Hua; Jin, Pengfei; Kan, Yunchao

    2010-12-01

    The present study elaborates a cost-effective and transfectant-free method for generating recombinant Bombyx mori (silkworm) nucleopolyhedrovirus in silkworm larvae and pupae by injecting invasive Escherichia coli carrying BmBacmid [BmNPV (B. mori nucleopolyhedrovirus)-Bacmid] into larval haemocoel. Up to 109 PFU (plaque-forming units)/ml of infective recombinant baculovirus was generated in the silkworm by intrahaemocoelic injection with 106 DAP (diaminopimelic acid) auxotrophic and BmBacmid containing E. coli cells expressing both invasin and listeriolysin. Thus 1 ml of overnight culture of E. coli is sufficient to inject more than 2000 larvae, while DAP costing up to $1 is enough to inject about 4000 larvae. Recombinant proteins can be controlled to be expressed mainly in pupae by adjusting the injection dose, too. In this new method, many original manipulations have been eliminated, including BmBacmid preparation and the subsequent complex transfection procedures. Hence it is a time- and cost-saving means for large-scale injection of B. mori for recombinant baculovirus production in comparison with the traditional transfection methods, which may play an important role in the industrial development of the BmNPV-silkworm bioreactor.

  11. Violence, trauma and living with HIV: Longitudinal predictors of initiating crystal methamphetamine injection among sex workers.

    PubMed

    Argento, Elena; Strathdee, Steffanie A; Goldenberg, Shira; Braschel, Melissa; Montaner, Julio; Shannon, Kate

    2017-06-01

    Despite rapid increases in crystal methamphetamine (CM) use worldwide and established gendered patterns of use, empirical research on CM injection initiation among sex workers is limited. Given the wide range of harms associated with CM, alongside stimulant effects including sexual dis-inhibition and prolonged awake-ness, this study aimed to longitudinally investigate socio-structural predictors of initiating CM injection among sex workers in Vancouver, Canada. Data (2010-2014) were drawn from a community-based cohort of women sex workers: AESHA (An Evaluation of Sex Workers Health Access). Participants completed bi-annual interviewer-administered questionnaires and HIV/STI testing. Kaplan Meier methods and Cox proportional hazards regression were used to model predictors of CM injection initiation among CM injection-naïve participants. Of 455 participants eligible at baseline, 14.3% (n=65) injected CM for the first time over follow-up, with an incidence density of 6.79 per 100 person-years (95% Confidence Interval [CI] 5.30-8.69). In multivariable analysis, injection heroin use (Adjusted Hazard Ratio [AHR] 6.11; 95%CI 3.24-11.52), having an intimate partner who injects drugs (AHR 2.93; 95%CI 1.57-5.46), workplace violence (AHR 2.85; 95%CI 1.74-4.67), HIV seropositivity (AHR 2.69; 95%CI 1.45-5.00), and childhood abuse (AHR 1.86; 95%CI 0.99-3.49) were independently associated with initiating CM injection. Findings underscore the gendered and social risk environment of CM injection initiation among sex workers. The strong influences of historical/workplace violence, coupled with heroin injection (known to be self-medicating for post-traumatic stress) as a primary risk pathway, emphasize the urgency of increasing access to integrated, trauma-informed addiction treatment and HIV care for marginalized women. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Treatment of lateral epicondilitis using three different local injection modalities: a randomized prospective clinical trial.

    PubMed

    Dogramaci, Yunus; Kalaci, Aydiner; Savaş, Nazan; Duman, I Gokhan; Yanat, A Nedim

    2009-10-01

    To determine the effectiveness of three different local injection modalities in the treatment of lateral epicondilitis. In a prospective randomized study on lateral epicondilitis, 75 patients were divided into three equal groups A, B and C (n = 25) and were treated using three different method of local injection. The patients in group A were treated with local injection of a steroid (1 mL triamcinolone) combined with local anaesthetic (1 mL lidocaine), those in group B were treated with injection of local anaesthetic (1 mL lidocaine) combined with peppering technique and those in group C with local injection of a steroid (1 mL triamcinolone) combined with local anaesthetic (1 mL lidocaine) and peppering technique. The outcome was defined by measuring the elbow pain during the activity using a 10-cm visual analogue scale (VAS) and satisfaction with the treatment using a scoring system based on the criteria of the Verhaar et al. at 3 weeks and 6 months after the injection and compared with the pre-treatment condition. There were significant (P = 0.006) differences in the successful outcomes between the three groups at 6 months. In group C in which local steroid + peppering injection technique were used; excellent results were obtained in 84% of patients comparing to 36% and 48% for patients in groups A and B, respectively. The successful outcomes were statistically higher in group C comparing to group A (P = 0.002) and group B (P = 0.011). In all groups, there was a significantly lower pain (VAS) at the 3-week and 6-month follow-ups comparing to the pre-treatment condition. VAS measured at 6-month follow-up were significantly lower in group C comparing to other groups (P = 0.002). In the treatment of lateral epicondilitis, combination of corticosteroid injections with peppering is more effective than corticosteroid injections or peppering injections alone and produces better clinical results.

  13. Injection Locking Techniques for Spectrum Analysis

    NASA Astrophysics Data System (ADS)

    Gathma, Timothy D.; Buckwalter, James F.

    2011-04-01

    Wideband spectrum analysis supports future communication systems that reconfigure and adapt to the capacity of the spectral environment. While test equipment manufacturers offer wideband spectrum analyzers with excellent sensitivity and resolution, these spectrum analyzers typically cannot offer acceptable size, weight, and power (SWAP). CMOS integrated circuits offer the potential to fully integrate spectrum analysis capability with analog front-end circuitry and digital signal processing on a single chip. Unfortunately, CMOS lacks high-Q passives and wideband resonator tunability that is necessary for heterodyne implementations of spectrum analyzers. As an alternative to the heterodyne receiver architectures, two nonlinear methods for performing wideband, low-power spectrum analysis are presented. The first method involves injecting the spectrum of interest into an array of injection-locked oscillators. The second method employs the closed loop dynamics of both injection locking and phase locking to independently estimate the injected frequency and power.

  14. Method and apparatus for injecting a substance into the bloodstream of a subject

    DOEpatents

    Lambrecht, Richard M.; Bennett, Gerald W.; Duncan, Charles C.; Ducote, Louis W.

    1983-10-18

    An apparatus and method for injecting a substance, such as a radiopharmaceutical, into the bloodstream of a subject. The apparatus comprises an injection means, such as a servo controlled syringe, a means for measuring the concentration of that substance in the subject's bloodstream, and means for controlling the injection in response to the measurement so that the concentration of the substance follows a predetermined function of time. The apparatus of the subject invention functions to inject a substance into a subject's bloodstream at a rate controlled by an error signal proportional to the difference between the concentration of the substance in the subject's bloodstream and the predetermined function.

  15. Method and apparatus for injecting a substance into the bloodstream of a subject

    DOEpatents

    Lambrecht, R.M.; Bennett, G.W.; Duncan, C.C.; Ducote, L.W.

    1983-10-18

    An apparatus and method is disclosed for injecting a substance, such as a radiopharmaceutical, into the bloodstream of a subject. The apparatus comprises an injection means, such as a servo controlled syringe, a means for measuring the concentration of that substance in the subject's bloodstream, and means for controlling the injection in response to the measurement so that the concentration of the substance follows a predetermined function of time. The apparatus of the subject invention functions to inject a substance into a subject's bloodstream at a rate controlled by an error signal proportional to the difference between the concentration of the substance in the subject's bloodstream and the predetermined function. 2 figs.

  16. Muon borehole detector development for use in four-dimensional tomographic density monitoring

    NASA Astrophysics Data System (ADS)

    Flygare, Joshua

    The increase of CO2 concentrations in the atmosphere and the correlated temperature rise has initiated research into methods of carbon sequestration. One promising possibility is to store CO2 in subsurface reservoirs of porous rock. After injection, the monitoring of the injected CO2 is of paramount importance because the CO2 plume, if escaped, poses health and environmental risks. Traditionally, seismic reflection methods are the chosen method of determining changes in the reservoir density due to CO2 injection, but this is expensive and not continuous. A potential and promising alternative is to use cosmic muon tomography to determine density changes in the reservoir over a period of time. The work I have completed was the development of a muon detector that will be capable of being deployed in boreholes and perform long-term tomography of the reservoir of interest. The detector has the required dimensions, an angular resolution of approximately 2 degrees, and is robust enough to survive the caustic nature of the fluids in boreholes, as well as temperature and pressure fluctuations. The detector design is based on polystyrene scintillating rods arrayed in alternating layers. The layers, as arranged, can provide four-dimensional (4D) tomographic data to detect small changes in density at depths up to approximately 2 kilometers. Geant4, a Monte Carlo simulation code, was used to develop and optimize the detector design. Additionally, I developed a method of determining the muon flux at depth, including CO2 saturation changes in subsurface reservoirs. Preliminary experiments were performed at Pacific Northwest National Laboratory. This thesis will show the simulations I performed to determine the angular resolution and background discrimination required of the detector, the experiments to determine light transport through the polystyrene scintillating rods and fibers, and the method developed to predict muon flux changes at depth expected after injection.

  17. Methods of Helium Injection and Removal for Heat Transfer Augmentation

    NASA Technical Reports Server (NTRS)

    Haight, Harlan; Kegley, Jeff; Bourdreaux, Meghan

    2008-01-01

    While augmentation of heat transfer from a test article by helium gas at low pressures is well known, the method is rarely employed during space simulation testing because the test objectives usually involve simulation of an orbital thermal environment. Test objectives of cryogenic optical testing at Marshall Space Flight Center's X-ray Cryogenic Facility (XRCF) have typically not been constrained by orbital environment parameters. As a result, several methods of helium injection have been utilized at the XRCF since 1999 to decrease thermal transition times. A brief synopsis of these injection (and removal) methods including will be presented.

  18. Methods of Helium Injection and Removal for Heat Transfer Augmentation

    NASA Technical Reports Server (NTRS)

    Kegley, Jeffrey

    2008-01-01

    While augmentation of heat transfer from a test article by helium gas at low pressures is well known, the method is rarely employed during space simulation testing because the test objectives are to simulate an orbital thermal environment. Test objectives of cryogenic optical testing at Marshall Space Flight Center's X-ray Calibration Facility (XRCF) have typically not been constrained by orbital environment parameters. As a result, several methods of helium injection have been utilized at the XRCF since 1999 to decrease thermal transition times. A brief synopsis of these injection (and removal) methods including will be presented.

  19. Toots, tastes and tester shots: user accounts of drug sampling methods for gauging heroin potency.

    PubMed

    Mars, Sarah G; Ondocsin, Jeff; Ciccarone, Daniel

    2018-05-16

    Internationally, overdose is the primary cause of death among people injecting drugs. However, since 2001, heroin-related overdose deaths in the United States (US) have risen sixfold, paralleled by a rise in the death rate attributed to synthetic opioids, particularly the fentanyls. This paper considers the adaptations some US heroin injectors are making to protect themselves from these risks. Between 2015 and 2016, a team of ethnographers collected data through semi-structured interviews and observation captured in field notes and video recording of heroin preparation/consumption. Ninety-one current heroin injectors were interviewed (Baltimore, n = 22; Chicago, n = 24; Massachusetts and New Hampshire, n = 36; San Francisco, n = 9). Experience injecting heroin ranged from < 1-47 years. Eight participants, who were exclusively heroin snorters, were also interviewed. Data were analyzed thematically. Across the study sites, multiple methods of sampling "heroin" were identified, sometimes used in combination, ranging from non-injecting routes (snorting, smoking or tasting a small amount prior to injection) to injecting a partial dose and waiting. Partial injection took different forms: a "slow shot" where the user injected a portion of the solution in the syringe, keeping the needle in the injection site, and continuing or withdrawing the syringe or a "tester shot" where the solution was divided into separate injections. Other techniques included getting feedback from others using heroin of the same batch or observing those with higher tolerance injecting heroin from the same batch before judging how much to inject themselves. Although a minority of those interviewed described using these drug sampling techniques, there is clearly receptivity among some users to protecting themselves by using a variety of methods. The use of drug sampling as a means of preventing an overdose from injection drug use reduces the quantity absorbed at any one time allowing users to monitor drug strength and titrate their dose accordingly. Given the highly unpredictable potency of the drugs currently being sold as heroin in the US, universal precautions should be adopted more widely. Further research is needed into facilitators and barriers to the uptake of these drug sampling methods.

  20. Hormonal induction of spawning in 4 species of frogs by coinjection with a gonadotropin-releasing hormone agonist and a dopamine antagonist

    PubMed Central

    2010-01-01

    Background It is well known that many anurans do not reproduce easily in captivity. Some methods are based on administration of mammalian hormones such as human chorionic gonadotropin, which are not effective in many frogs. There is a need for simple, cost-effective alternative techniques to induce spawning. Methods Our new method is based on the injection of a combination of a gonadotropin-releasing hormone (GnRH) agonist and a dopamine antagonist. We have named this formulation AMPHIPLEX, which is derived from the combination of the words amphibian and amplexus. This name refers to the specific reproductive behavior of frogs when the male mounts and clasps the female to induce ovulation and to fertilize the eggs as they are laid. Results We describe the use of the method and demonstrate its applicability for captive breeding in 3 different anuran families. We tested several combinations of GnRH agonists with dopamine antagonists using Lithobates pipiens. The combination of des-Gly10, D-Ala6, Pro-LHRH (0.4 microrams/g body weight) and metoclopramide (10 micrograms/g BWt. MET) was most effective. It was used in-season, after short-term captivity and in frogs artificially hibernated under laboratory conditions. The AMPHIPLEX method was also effective in 3 Argentinian frogs, Ceratophrys ornata, Ceratophrys cranwelli and Odontophrynus americanus. Conclusion Our approach offers some advantages over other hormonally-based techniques. Both sexes are injected only once and at the same time, reducing handling stress. AMPHIPLEX is a new reproductive management tool for captive breeding in Anura. PMID:20398399

Top