NASA Astrophysics Data System (ADS)
Eom, JiYong; Kim, DongYung; Kwon, HyukSang
The effects of ball-milling on Li insertion into multi-walled carbon nanotubes (MWNTs) are presented. The MWNTs are synthesized on supported catalysts by thermal chemical vapour deposition, purified, and mechanically ball-milled by the high energy ball-milling. The purified MWNTs and the ball-milled MWNTs were electrochemically inserted with Li. Structural and chemical modifications in the ball-milled MWNTs change the insertion-extraction properties of Li ions into/from the ball-milled MWNTs. The reversible capacity (C rev) increases with increasing ball-milling time, namely, from 351 mAh g -1 (Li 0.9C 6) for the purified MWNTs to 641 mAh g -1 (Li 1.7C 6) for the ball-milled MWNTs. The undesirable irreversible capacity (C irr) decreases continuously with increase in the ball-milling time, namely, from 1012 mAh g -1 (Li 2.7C 6) for the purified MWNTs to 518 mAh g -1 (Li 1.4C 6) for the ball-milled MWNTs. The decrease in C irr of the ball-milled samples results in an increase in the coulombic efficiency from 25% for the purified samples to 50% for the ball-milled samples. In addition, the ball-milled samples maintain a more stable capacity than the purified samples during charge-discharge cycling.
NASA Astrophysics Data System (ADS)
Odedeyi, P. B.; Abou-El-Hossein, K.; Liman, M.
2017-05-01
Stainless steel 316 is a difficult-to-machine iron-based alloys that contain minimum of about 12% of chromium commonly used in marine and aerospace industry. This paper presents an experimental study of the tool wear propagation variations in the end milling of stainless steel 316 with coated carbide inserts. The milling tests were conducted at three different cutting speeds while feed rate and depth of cut were at (0.02, 0.06 and 01) mm/rev and (1, 2 and 3) mm, respectively. The cutting tool used was TiAlN-PVD-multi-layered coated carbides. The effects of cutting speed, cutting tool coating top layer and workpiece material were investigated on the tool life. The results showed that cutting speed significantly affected the machined flank wears values. With increasing cutting speed, the flank wear values decreased. The experimental results showed that significant flank wear was the major and predominant failure mode affecting the tool life.
Reducing tool wear by partial cladding of critical zones in hot form tool by laser metal deposition
NASA Astrophysics Data System (ADS)
Vollmer, Robert; Sommitsch, Christof
2017-10-01
This paper points out a production method to reduce tool wear in hot stamping applications. Usually tool wear can be observed at locally strongly stressed areas superimposed with gliding movement between blank and tool surface. The shown solution is based on a partial laser cladding of the tool surface with a wear resistant coating to increase the lifespan of tool inserts. Preliminary studies showed good results applying a material combination of tungsten carbide particles embedded in a metallic matrix. Different Nickel based alloys welded on hot work tool steel (1.2343) were tested mechanically in the interface zone. The material with the best bonding characteristic is chosen and reinforced with spherical tungsten carbide particles in a second laser welding step. Since the machining of tungsten carbides is very elaborate a special manufacturing strategy is developed to reduce the milling effort as much as possible. On special test specimens milling tests are carried out to proof the machinability. As outlook a tool insert of a b-pillar is coated to perform real hot forming tests.
Proussaefs, Periklis
2016-11-01
This article describes a technique in which a custom-made computer-aided design and computer-aided manufacturing (CAD-CAM) healing abutment milled from a poly(methyl methacrylate) (PMMA) block is fabricated and bonded to a titanium metal insert. An impression is made during dental implant surgery, and the CAD-CAM custom-made healing abutment is fabricated before second-stage surgery while appropriate healing time is allowed for the dental implant to osseointegrate. The contours of the healing abutment are based on the contours of a tentatively designed definitive prosthesis. The healing tissue obtains contours that will be compatible with the contours of the definitive prosthesis. After the milling process is complete, a titanium metal insert is bonded to the healing abutment. Placement of the custom-made CAD-CAM healing abutment at second-stage surgery allows the tissue to obtain contours similar to those of the definitive prosthesis. A custom-made CAD-CAM impression coping milled from a PMMA block and with a titanium insert is used for the definitive impression after the soft tissue has healed. This technique allows guided soft tissue healing by using a custom-made CAD-CAM healing abutment and impression coping. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Mebrahitom, A.; Rizuan, D.; Azmir, M.; Nassif, M.
2016-02-01
High speed milling is one of the recent technologies used to produce mould inserts due to the need for high surface finish. It is a faster machining process where it uses a small side step and a small down step combined with very high spindle speed and feed rate. In order to effectively use the HSM capabilities, optimizing the tool path strategies and machining parameters is an important issue. In this paper, six different tool path strategies have been investigated on the surface finish and machining time of a rectangular cavities of ESR Stavax material. CAD/CAM application of CATIA V5 machining module for pocket milling of the cavities was used for process planning.
Micro Machining of Injection Mold Inserts for Fluidic Channel of Polymeric Biochips
Jung, Woo-Chul; Heo, Young-Moo; Yoon, Gil-Sang; Shin, Kwang-Ho; Chang, Sung-Ho; Kim, Gun-Hee; Cho, Myeong-Woo
2007-01-01
Recently, the polymeric micro-fluidic biochip, often called LOC (lab-on-a-chip), has been focused as a cheap, rapid and simplified method to replace the existing biochemical laboratory works. It becomes possible to form miniaturized lab functionalities on a chip with the development of MEMS technologies. The micro-fluidic chips contain many micro-channels for the flow of sample and reagents, mixing, and detection tasks. Typical substrate materials for the chip are glass and polymers. Typical techniques for microfluidic chip fabrication are utilizing various micro pattern forming methods, such as wet-etching, micro-contact printing, and hot-embossing, micro injection molding, LIGA, and micro powder blasting processes, etc. In this study, to establish the basis of the micro pattern fabrication and mass production of polymeric micro-fluidic chips using injection molding process, micro machining method was applied to form micro-channels on the LOC molds. In the research, a series of machining experiments using micro end-mills were performed to determine optimum machining conditions to improve surface roughness and shape accuracy of designed simplified micro-channels. Obtained conditions were used to machine required mold inserts for micro-channels using micro end-mills. Test injection processes using machined molds and COC polymer were performed, and then the results were investigated.
Half-BPS Wilson loop and AdS 2/CFT 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giombi, Simone; Roiban, Radu; Tseytlin, Arkady A.
Here, we study correlation functions of local operator insertions on the 1/2-BPS Wilson line in N=4 super Yang–Mills theory. These correlation functions are constrained by the 1d superconformal symmetry pre-served by the 1/2-BPS Wilson line and define a defect CFT 1 living on the line. At strong coupling, a set of elementary operator insertions with protected scaling dimensions correspond to fluctuations of the dual fundamental string in AdS 5×S 5 ending on the line at the boundary and can be thought of as light fields propagating on the AdS 2 worldsheet. We use AdS/CFT techniques to compute the tree-level AdSmore » 2 Witten diagrams describing the strong coupling limit of the four-point functions of the dual operator insertions. Using the OPE, we also extract the leading strong coupling corrections to the anomalous dimensions of the “two-particle” operators built out of elementary excitations. In the case of the circular Wilson loop, we match our results for the 4-point functions of a special type of scalar insertions to the prediction of localization to 2d Yang–Mills theory.« less
Half-BPS Wilson loop and AdS 2/CFT 1
Giombi, Simone; Roiban, Radu; Tseytlin, Arkady A.
2017-09-01
Here, we study correlation functions of local operator insertions on the 1/2-BPS Wilson line in N=4 super Yang–Mills theory. These correlation functions are constrained by the 1d superconformal symmetry pre-served by the 1/2-BPS Wilson line and define a defect CFT 1 living on the line. At strong coupling, a set of elementary operator insertions with protected scaling dimensions correspond to fluctuations of the dual fundamental string in AdS 5×S 5 ending on the line at the boundary and can be thought of as light fields propagating on the AdS 2 worldsheet. We use AdS/CFT techniques to compute the tree-level AdSmore » 2 Witten diagrams describing the strong coupling limit of the four-point functions of the dual operator insertions. Using the OPE, we also extract the leading strong coupling corrections to the anomalous dimensions of the “two-particle” operators built out of elementary excitations. In the case of the circular Wilson loop, we match our results for the 4-point functions of a special type of scalar insertions to the prediction of localization to 2d Yang–Mills theory.« less
Mathematical Modeling of Thermofrictional Milling Process Using ANSYS WB Software
NASA Astrophysics Data System (ADS)
Sherov, K. T.; Sikhimbayev, M. R.; Sherov, A. K.; Donenbayev, B. S.; Rakishev, A. K.; Mazdubai, A. B.; Musayev, M. M.; Abeuova, A. M.
2017-06-01
This article presents ANSYS WB-based mathematical modelling of the thermofrictional milling process, which allowed studying the dynamics of thermal and physical processes occurring during the processing. The technique used also allows determination of the optimal cutting conditions of thermofrictional milling for processing various materials, in particular steel 40CN2MA, 30CGSA, 45, 3sp. In our study, from among a number of existing models of cutting fracture, we chose the criterion first proposed by prof. V. L. Kolmogorov. In order to increase the calculations performance, a mathematical model was proposed, that used only two objects: a parallelepiped-shaped workpiece and a cutting insert in the form of a pentagonal prism. In addition, the work takes into account the friction coefficient between a cutting insert and a workpiece taken equal to 0.4 mm. To determine the temperature in the subcontact layer of the workpiece, we introduced the coordinates of nine characteristic points with the same interval in the local coordinate system. As a result, the temperature values were obtained for different materials at the studied points during the cutter speed change. The research results showed the possibility of controlling thermal processes during processing by choosing the optimum cutting modes.
Wear of carbide inserts with complex surface treatment when milling nickel alloy
NASA Astrophysics Data System (ADS)
Fedorov, Sergey; Swe, Min Htet; Kapitanov, Alexey; Egorov, Sergey
2018-03-01
One of the effective ways of strengthening hard alloys is the creating structure layers on their surface with the gradient distribution of physical and mechanical properties between the wear-resistant coating and the base material. The article discusses the influence of the near-surface layer which is modified by low-energy high-current electron-beam alloying and the upper anti-friction layer in a multi-component coating on the wear mechanism of the replaceable multifaceted plates in the dry milling of the difficult to machine nickel alloys.
Modelling of teeth of a gear transmission for modern manufacturing technologies
NASA Astrophysics Data System (ADS)
Monica, Z.; Banaś, W.; Ćwikla, G.; Topolska, S.
2017-08-01
The technological process of manufacturing of gear wheels is influenced by many factors. It is designated depending on the type of material from which the gear is to be produced, its heat treatment parameters, the required accuracy, the geometrical form and the modifications of the tooth. Therefor the parameters selection process is not easy and moreover it is unambiguous. Another important stage of the technological process is the selection of appropriate tools to properly machine teeth in the operations of both roughing and finishing. In the presented work the focus is put first of all on modern production methods of gears using technologically advanced instruments in comparison with conventional tools. Conventional processing tools such as gear hobbing cutters or Fellows gear-shaper cutters are used from the beginning of the machines for the production of gear wheels. With the development of technology and the creation of CNC machines designated for machining of gears wheel it was also developed the manufacturing technology as well as the design knowledge concerning the technological tools. Leading manufacturers of cutting tools extended the range of tools designated for machining of gears on the so-called hobbing cutters with inserted cemented carbide tips. The same have be introduced to Fellows gear-shaper cutters. The results of tests show that is advantaged to use hobbing cutters with inserted cemented carbide tips for milling gear wheels with a high number of teeth, where the time gains are very high, in relation to the use of conventional milling cutters.
NASA Astrophysics Data System (ADS)
Bondarenko, J. A.; Fedorenko, M. A.; Pogonin, A. A.
2018-03-01
The loading and unloading units and grinding mills of raw devices have internal cone type or pipe screw perceive load of incoming and outgoing material. The main part of the support assembly is a pin. Mounting seats for the pipe screws cone have traces of deformation and work hardening, while they themselves have wear of pins and deformation of the inner and outer cylindrical working surface. In the mill body, there are constantly acting dynamic forces causing vibration, which are transmitted to the stud and inner accelerating elements. Under the influence of stress and vibration, the housing spigot is in the stress-compressed state and stretched vertically and horizontally. As a result, the insertion element is deformed and weakened in the fixture. A moving element appears in the gap leading to the fact that it drops lfeedstock and under the influence of variable loads it is destroyed, as well as the seating surfaces of the insert pin member.
Chairside multi-unit restoration of a quadrant using the new Cerec 3D software.
Ender, A; Wiedhahn, K; Mörmann, W H
2003-01-01
The new Cerec 3D design software for inlays and partial and full crowns simplifies work when producing several restorations in one session. Quite significant progress has been achieved, in that the entire row of teeth of a quadrant can be acquired completely and displayed by successively overlapping optical impressions. The digital working model of a quadrant in which all preparations are acquired is the result. The restorations can be designed individually and inserted virtually. Thanks to virtual insertion, the proximal contacts to neighboring restorations can be designed perfectly and all restorations finally designed, milled, and inserted in one sitting. This method provides a significant rationalization effect.
Fracture strength of orthodontic mini-implants
Assad-Loss, Tatiana Feres; Kitahara-Céia, Flávia Mitiko Fernandes; Silveira, Giordani Santos; Elias, Carlos Nelson; Mucha, José Nelson
2017-01-01
ABSTRACT Objective: This study aimed at evaluating the design and dimensions of five different brands of orthodontic mini-implants, as well as their influence on torsional fracture strength. Methods: Fifty mini-implants were divided into five groups corresponding to different manufactures (DEN, RMO, CON, NEO, SIN). Twenty-five mini-implants were subjected to fracture test by torsion in the neck and the tip, through arbors attached to a Universal Mechanical Testing Machine. The other 25 mini-implants were subjected to insertion torque test into blocks of pork ribs using a torquimeter and contra-angle handpiece mounted in a surgical motor. The shape of the active tip of the mini-implants was evaluated under microscopy. The non-parametric Friedman test and Snedecor’s F in analysis of variance (ANOVA) were used to evaluate the differences between groups. Results: The fracture torque of the neck ranged from 23.45 N.cm (DEN) to 34.82 N.cm (SIN), and of the tip ranged from 9.35 N.cm (CON) to 24.36 N.cm (NEO). Insertion torque values ranged from 6.6 N.cm (RMO) to 10.2 N.cm (NEO). The characteristics that most influenced the results were outer diameter, inner diameter, the ratio between internal and external diameters, and the existence of milling in the apical region of the mini-implant. Conclusions: The fracture torques were different for both the neck and the tip of the five types evaluated. NEO and SIN mini-implants showed the highest resistance to fracture of the neck and tip. The fracture torques of both tip and neck were higher than the torque required to insert mini-implants. PMID:28746487
Lava ultimate resin nano ceramic for CAD/ CAM: customization case study.
Koller, M; Arnetzl, G V; Holly, L; Arnetzl, G
2012-01-01
Lava Ultimate Resin Nano Ceramic (RNC) blocks are innovative new CAD/CAM materials that make it possible to achieve superior esthetic results in easy steps. The blocks are made of nano ceramic particles embedded in a highly cured resin matrix. Therefore, composite materials can be used to characterize and adjust resin nano ceramic restorations after milling. The milled RNC restorations can be individualized intra-orally or extra-orally, either before or after insertion. Unlike conventional ceramic restorations, customization and glaze firing is neither necessary nor possible with RNC restorations. This opens up the opportunity for intraoral individualization and adaptation of the restorations.
Insertion compounds and composites made by ball milling for advanced sodium-ion batteries
Zhang, Biao; Dugas, Romain; Rousse, Gwenaelle; Rozier, Patrick; Abakumov, Artem M.; Tarascon, Jean-Marie
2016-01-01
Sodium-ion batteries have been considered as potential candidates for stationary energy storage because of the low cost and wide availability of Na sources. However, their future commercialization depends critically on control over the solid electrolyte interface formation, as well as the degree of sodiation at the positive electrode. Here we report an easily scalable ball milling approach, which relies on the use of metallic sodium, to prepare a variety of sodium-based alloys, insertion layered oxides and polyanionic compounds having sodium in excess such as the Na4V2(PO4)2F3 phase. The practical benefits of preparing sodium-enriched positive electrodes as reservoirs to compensate for sodium loss during solid electrolyte interphase formation are demonstrated by assembling full C/P′2-Na1[Fe0.5Mn0.5]O2 and C/‘Na3+xV2(PO4)2F3' sodium-ion cells that show substantial increases (>10%) in energy storage density. Our findings may offer electrode design principles for accelerating the development of the sodium-ion technology. PMID:26777573
2D Kac-Moody symmetry of 4D Yang-Mills theory
He, Temple; Mitra, Prahar; Strominger, Andrew
2016-10-25
Scattering amplitudes of any four-dimensional theory with nonabelian gauge group G may be recast as two-dimensional correlation functions on the asymptotic twosphere at null in nity. The soft gluon theorem is shown, for massless theories at the semiclassical level, to be the Ward identity of a holomorphic two-dimensional G-Kac-Moody symmetry acting on these correlation functions. Holomorphic Kac-Moody current insertions are positive helicity soft gluon insertions. Furthermore, the Kac-Moody transformations are a CPT invariant subgroup of gauge transformations which act nontrivially at null in nity and comprise the four-dimensional asymptotic symmetry group.
A Virtual Sensor for Online Fault Detection of Multitooth-Tools
Bustillo, Andres; Correa, Maritza; Reñones, Anibal
2011-01-01
The installation of suitable sensors close to the tool tip on milling centres is not possible in industrial environments. It is therefore necessary to design virtual sensors for these machines to perform online fault detection in many industrial tasks. This paper presents a virtual sensor for online fault detection of multitooth tools based on a Bayesian classifier. The device that performs this task applies mathematical models that function in conjunction with physical sensors. Only two experimental variables are collected from the milling centre that performs the machining operations: the electrical power consumption of the feed drive and the time required for machining each workpiece. The task of achieving reliable signals from a milling process is especially complex when multitooth tools are used, because each kind of cutting insert in the milling centre only works on each workpiece during a certain time window. Great effort has gone into designing a robust virtual sensor that can avoid re-calibration due to, e.g., maintenance operations. The virtual sensor developed as a result of this research is successfully validated under real conditions on a milling centre used for the mass production of automobile engine crankshafts. Recognition accuracy, calculated with a k-fold cross validation, had on average 0.957 of true positives and 0.986 of true negatives. Moreover, measured accuracy was 98%, which suggests that the virtual sensor correctly identifies new cases. PMID:22163766
A virtual sensor for online fault detection of multitooth-tools.
Bustillo, Andres; Correa, Maritza; Reñones, Anibal
2011-01-01
The installation of suitable sensors close to the tool tip on milling centres is not possible in industrial environments. It is therefore necessary to design virtual sensors for these machines to perform online fault detection in many industrial tasks. This paper presents a virtual sensor for online fault detection of multitooth tools based on a bayesian classifier. The device that performs this task applies mathematical models that function in conjunction with physical sensors. Only two experimental variables are collected from the milling centre that performs the machining operations: the electrical power consumption of the feed drive and the time required for machining each workpiece. The task of achieving reliable signals from a milling process is especially complex when multitooth tools are used, because each kind of cutting insert in the milling centre only works on each workpiece during a certain time window. Great effort has gone into designing a robust virtual sensor that can avoid re-calibration due to, e.g., maintenance operations. The virtual sensor developed as a result of this research is successfully validated under real conditions on a milling centre used for the mass production of automobile engine crankshafts. Recognition accuracy, calculated with a k-fold cross validation, had on average 0.957 of true positives and 0.986 of true negatives. Moreover, measured accuracy was 98%, which suggests that the virtual sensor correctly identifies new cases.
Bremsstrahlung function, leading Lüscher correction at weak coupling and localization
NASA Astrophysics Data System (ADS)
Bonini, Marisa; Griguolo, Luca; Preti, Michelangelo; Seminara, Domenico
2016-02-01
We discuss the near BPS expansion of the generalized cusp anomalous dimension with L units of R-charge. Integrability provides an exact solution, obtained by solving a general TBA equation in the appropriate limit: we propose here an alternative method based on supersymmetric localization. The basic idea is to relate the computation to the vacuum expectation value of certain 1/8 BPS Wilson loops with local operator insertions along the contour. These observables localize on a two-dimensional gauge theory on S 2, opening the possibility of exact calculations. As a test of our proposal, we reproduce the leading Lüscher correction at weak coupling to the generalized cusp anomalous dimension. This result is also checked against a genuine Feynman diagram approach in {N}=4 Super Yang-Mills theory.
Evaluation of End Mill Coatings
DOE Office of Scientific and Technical Information (OSTI.GOV)
L. J. Lazarus; R. L. Hester,
2005-08-01
Milling tests were run on families of High Speed Steel (HSS) end mills to determine their lives while machining 304 Stainless Steel. The end mills tested were made from M7, M42 and T15-CPM High Speed Steels. The end mills were also evaluated with no coatings as well as with Titanium Nitride (TiN) and Titanium Carbo-Nitride (TiCN) coatings to determine which combination of HSS and coating provided the highest increase in end mill life while increasing the cost of the tool the least. We found end mill made from M42 gave us the largest increase in tool life with the leastmore » increase in cost. The results of this study will be used by Cutting Tool Engineering in determining which end mill descriptions will be dropped from our tool catalog.« less
Design and Testing of UMM Vertical Ball Mill (UVBM) for producing Aluminium Powder
NASA Astrophysics Data System (ADS)
Aisyah, I. S.; Caesarendra, Wahyu; Suprihanto, Agus
2018-04-01
UMM Vertical Ball Mill (UVBM) was intended to be the apparatus to produce metal powder with superior characteristic in production rate while retaining good quality of metal powder. The concept of design was adopting design theory of Phal and Beitz with emphasis on increasing of probability of success in engineering and economy aspects.Since it was designed as vertical ball mill, a new way to produce powder, then it need to be tested for the performance after manufactured. The test on UVBM was carried out by milling of aluminium chip for 5 (five) different milling time of 0.5 hours, 1 hour, 3 hours, 5 hours and 7 hours, and the powder product then be characterized for it morphology and size using Scanning Electron Microscope (SEM) and Sieve.The results of the study were the longer of the milling time, the finer of the powder. From the test results of SEM, the morphology of the powder with 5 variations of milling time were most of the powder in form of flake (flat), small round and angular (irregular). The distribution of powder size was best obtained on the variation of milling time 3 hours, 5 hours, and 7 hours with percentage of 200 mesh in size of 22.14 %, 64 % and 91.25 % respectively.
Tool wear analysis during duplex stainless steel trochoidal milling
NASA Astrophysics Data System (ADS)
Amaro, Paulo; Ferreira, Pedro; Simões, Fernando
2018-05-01
In this study a tool with interchangeable inserts of sintered carbides coated with AlTiN were used to mill a duplex stainless steel with trochoidal strategies. Cutting speed range from 120 to 300 m/min were used and t he evaluation of tool deterioration and tool life was made according international standard ISO 8688-1. It was observed a progressive development of a flank wear and a cumulative cyclic process of localized adhesion of the chip to the cutting edge, followed by chipping, loss of the coating and substrate exposure. The tool life reached a maximum of 35 min. for cutting speed of 120 m/min. However, it was possible to maintain a tool life of 20-25 minutes when the cutting speed was increased up to 240 m/min.
Hamza, Tamer A; Sherif, Rana M
2017-06-01
Dental laboratories use different computer-aided design and computer-aided manufacturing (CAD-CAM) systems to fabricate fixed prostheses; however, limited evidence is available concerning which system provides the best marginal discrepancy. The purpose of this in vitro study was to evaluate the marginal fit of 5 different monolithic zirconia restorations milled with different CAD-CAM systems. Thirty monolithic zirconia crowns were fabricated on a custom-designed stainless steel die and were divided into 5 groups according to the type of monolithic zirconia crown and the CAD-CAM system used: group TZ, milled with an MCXL milling machine; group CZ, translucent zirconia milled with a motion milling machine; group ZZ, zirconia milled with a dental milling unit; group PZ, translucent zirconia milled with a zirconia milling unit; and group BZ, solid zirconia milled using an S1 VHF milling machine. The marginal fit was measured with a binocular microscope at an original magnification of ×100. The results were tabulated and statistically analyzed with 1-way ANOVA and post hoc surface range test, and pairwise multiple comparisons were made using Bonferroni correction (α=.05). The type of CAD-CAM used affected the marginal fit of the monolithic restoration. The mean (±SD) highest marginal discrepancy was recorded in group TZI at 39.3 ±2.3 μm, while the least mean marginal discrepancy was recorded in group IZ (22.8 ±8.9 μm). The Bonferroni post hoc test showed that group TZI was significantly different from all other groups tested (P<.05). Within the limitation of this in vitro study, all tested CAD-CAM systems produced monolithic zirconia restorations with clinically acceptable marginal discrepancies; however, the CAD-CAM system with the 5-axis milling unit produced the best marginal fit. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Prasetya, A.; Mawadati, A.; Putri, A. M. R.; Petrus, H. T. B. M.
2018-01-01
Comminution is one of crucial steps in gold ore processing used to liberate the valuable minerals from gaunge mineral. This research is done to find the particle size distribution of gold ore after it has been treated through the comminution process in a rod mill with various number of rod and rotational speed that will results in one optimum milling condition. For the initial step, Sumbawa gold ore was crushed and then sieved to pass the 2.5 mesh and retained on the 5 mesh (this condition was taken to mimic real application in artisanal gold mining). Inserting the prepared sample into the rod mill, the observation on effect of rod-number and rotational speed was then conducted by variating the rod number of 7 and 10 while the rotational speed was varied from 60, 85, and 110 rpm. In order to be able to provide estimation on particle distribution of every condition, the comminution kinetic was applied by taking sample at 15, 30, 60, and 120 minutes for size distribution analysis. The change of particle distribution of top and bottom product as time series was then treated using Rosin-Rammler distribution equation. The result shows that the homogenity of particle size and particle size distribution is affected by rod-number and rotational speed. The particle size distribution is more homogeneous by increasing of milling time, regardless of rod-number and rotational speed. Mean size of particles do not change significantly after 60 minutes milling time. Experimental results showed that the optimum condition was achieved at rotational speed of 85 rpm, using rod-number of 7.
Hollow cathode startup using a microplasma discharge
NASA Technical Reports Server (NTRS)
Aston, G.
1981-01-01
Attention is given to a microplasma discharge to initiate a hollow cathode discharge for such applications as plasma flow experiments, the electric propulsion of space vehicles, and as a replacement for filament cathodes in neutral beam injector ion sources. The technique results in a cathode that is easy to start, simple in design, and which does not require external RF exciters, inserts or heating elements. Future applications may include ion beam milling and ion implantation.
NASA Astrophysics Data System (ADS)
Czán, Andrej; Kubala, Ondrej; Danis, Igor; Czánová, Tatiana; Holubják, Jozef; Mikloš, Matej
2017-12-01
The ever-increasing production and the usage of hard-to-machine progressive materials are the main cause of continual finding of new ways and methods of machining. One of these ways is the ceramic milling tool, which combines the pros of conventional ceramic cutting materials and pros of conventional coating steel-based insert. These properties allow to improve cutting conditions and so increase the productivity with preserved quality known from conventional tools usage. In this paper, there is made the identification of properties and possibilities of this tool when machining of hard-to-machine materials such as nickel alloys using in airplanes engines. This article is focused on the analysis and evaluation ordinary technological parameters and surface quality, mainly roughness of surface and quality of machined surface and tool wearing.
Crystallization of high-strength nano-scale leucite glass-ceramics.
Theocharopoulos, A; Chen, X; Wilson, R M; Hill, R; Cattell, M J
2013-11-01
Fine-grained, high strength, translucent leucite dental glass-ceramics are synthesized via controlled crystallization of finely milled glass powders. The objectives of this study were to utilize high speed planetary milling of an aluminosilicate glass for controlled surface crystallization of nano-scale leucite glass-ceramics and to test the biaxial flexural strength. An aluminosilicate glass was synthesized, attritor or planetary milled and heat-treated. Glasses and glass-ceramics were characterized using particle size analysis, X-ray diffraction and scanning electron microscopy. Experimental (fine and nanoscale) and commercial (Ceramco-3, IPS Empress Esthetic) leucite glass-ceramics were tested using the biaxial flexural strength (BFS) test. Gaussian and Weibull statistics were applied. Experimental planetary milled glass-ceramics showed an increased leucite crystal number and nano-scale median crystal sizes (0.048-0.055 μm(2)) as a result of glass particle size reduction and heat treatments. Experimental materials had significantly (p<0.05) higher mean BFS and characteristic strength values than the commercial materials. Attritor milled and planetary milled (2h) materials showed no significant (p>0.05) strength difference. All other groups' mean BFS and characteristic strengths were found to be significantly different (p<0.05) to each other. The mean (SD) MPa strengths measured were: Attritor milled: 252.4 (38.7), Planetary milled: 225.4 (41.8) [4h milling] 255.0 (35.0) [2h milling], Ceramco-3: 75.7 (6.8) and IPS Empress: 165.5 (30.6). Planetary milling enabled synthesis of nano-scale leucite glass-ceramics with high flexural strength. These materials may help to reduce problems associated with brittle fracture of all-ceramic restorations and give reduced enamel wear. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Zhang, Lin; Zhou, Wenchen; Naples, Neil J; Yi, Allen Y
2018-05-01
A novel fabrication method by combining high-speed single-point diamond milling and precision compression molding processes for fabrication of discontinuous freeform microlens arrays was proposed. Compared with slow tool servo diamond broaching, high-speed single-point diamond milling was selected for its flexibility in the fabrication of true 3D optical surfaces with discontinuous features. The advantage of single-point diamond milling is that the surface features can be constructed sequentially by spacing the axes of a virtual spindle at arbitrary positions based on the combination of rotational and translational motions of both the high-speed spindle and linear slides. By employing this method, each micro-lenslet was regarded as a microstructure cell by passing the axis of the virtual spindle through the vertex of each cell. An optimization arithmetic based on minimum-area fabrication was introduced to the machining process to further increase the machining efficiency. After the mold insert was machined, it was employed to replicate the microlens array onto chalcogenide glass. In the ensuing optical measurement, the self-built Shack-Hartmann wavefront sensor was proven to be accurate in detecting an infrared wavefront by both experiments and numerical simulation. The combined results showed that precision compression molding of chalcogenide glasses could be an economic and precision optical fabrication technology for high-volume production of infrared optics.
Experimental Comparison of Face-Milled and Face-Hobbed Spiral Bevel Gears
NASA Technical Reports Server (NTRS)
Handschuh, Robert F.; Nanlawala, Michael; Hawkins, John M.; Mahan, Danny
2001-01-01
An experimental comparison of face-milled and face-hobbed spiral bevel gears was accomplished. The two differently manufactured spiral bevel gear types were tested in a closed-loop facility at NASA Glenn Research Center. Strain, vibration, and noise testing were completed at various levels of rotational speed and load. Tests were conducted from static (slow-roll) to 12600 rpm and up to 269 N-m (2380 in.-lb) pinion speed and load conditions. The tests indicated that the maximum stress recorded at the root locations had nearly the same values, however the stress distribution was different from the toe to the heel. Also, the alternating stress measured was higher for the face-milled pinion than that attained for the face-hobbed pinion (larger minimum stress). The noise and vibration results indicated that the levels measured for the face-hobbed components were less than those attained for the face-milled gears tested.
The effect of milling and postmilling procedures on the surface roughness of CAD/CAM materials.
Mota, Eduardo Gonçalves; Smidt, Laura Nunes; Fracasso, Lisiane Martins; Burnett, Luiz Henrique; Spohr, Ana Maria
2017-11-12
The aim of this study was to evaluate the surface roughness and analyze the surface topography of five different CAD/CAM ceramics and one CAD/CAM composite resin for CEREC after milling and postmilling procedures. Blocks of the ceramics Mark II, IPS Empress CAD, IPS e.max CAD, Suprinity and Enamic, and blocks of the composite resin Lava Ultimate were milled at CEREC MCXL. Ten flat samples of each material were obtained. The surface roughness (Ra) test was performed before and after milling, crystallization, polishing, and glaze when indicated, followed by SEM and AFM analysis. Data were submitted to one-way ANOVA with repeated measures and the Tukey HSD test (α = 0.05). The milling step significantly increased the roughness of all the tested materials (P < .05). Lithium-based ceramics (IPS e.max CAD and Suprinity) were more suitable to roughness than the other tested materials (P < .05). The polishing methods were able to reduce roughness to baseline values, except for lithium-based ceramics. Glaze reduced significantly the roughness of lithium-based ceramics without a difference from the baseline. SEM and AFM images revealed that glazed surfaces are smoother than polished surfaces. All hard-milling CAD/CAM materials, that is, fully sintered, should be only hand polished. The glaze step can be suppressed resulting in time saving. However, the glaze step in soft-milling lithium disilicate is imperative. © 2017 Wiley Periodicals, Inc.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (1985). (13) Mill T., Hendry D.G., Richardson H. “Free radical oxidants in natural waters.” Science, 207...)(7) of this section); peroxy radicals (RO2−) (Mill et al. (1981) under paragraph (f)(9) of this section; Mill et al. (1983) under paragraph (f)(8) of this section); hydroxyl radicals (HO−) (Mill et al...
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (1985). (13) Mill T., Hendry D.G., Richardson H. “Free radical oxidants in natural waters.” Science, 207...)(7) of this section); peroxy radicals (RO2−) (Mill et al. (1981) under paragraph (f)(9) of this section; Mill et al. (1983) under paragraph (f)(8) of this section); hydroxyl radicals (HO−) (Mill et al...
Rodríguez-Tizcareño, Mario H; Barajas, Lizbeth; Pérez-Gásque, Marisol; Gómez, Salvador
2012-06-01
This report presents a protocol used to transfer the virtual treatment plan data to the surgical and prosthetic reality and its clinical application, bone site augmentation with computer-custom milled bovine bone graft blocks to their ideal architecture form, implant insertion based on image-guided stent fabrication, and the restorative manufacturing process through computed tomography-based software programs and navigation systems and the computer-aided design and manufacturing techniques for the treatment of the edentulous maxilla.
NASA Astrophysics Data System (ADS)
Ravi, S.; Pradeep Kumar, M.
2011-09-01
Milling of hardened steel generates excessive heat during the chip formation process, which increases the temperature of cutting tool and accelerates tool wear. Application of conventional cutting fluid in milling process may not effectively control the heat generation also it has inherent health and environmental problems. To minimize health hazard and environmental problems caused by using conventional cutting fluid, a cryogenic cooling set up is developed to cool tool-chip interface using liquid nitrogen (LN 2). This paper presents results on the effect of LN 2 as a coolant on machinability of hardened AISI H13 tool steel for varying cutting speed in the range of 75-125 m/min during end milling with PVD TiAlN coated carbide inserts at a constant feed rate. The results show that machining with LN 2 lowers cutting temperature, tool flank wear, surface roughness and cutting forces as compared with dry and wet machining. With LN 2 cooling, it has been found that the cutting temperature was reduced by 57-60% and 37-42%; the tool flank wear was reduced by 29-34% and 10-12%; the surface roughness was decreased by 33-40% and 25-29% compared to dry and wet machining. The cutting forces also decreased moderately compared to dry and wet machining. This can be attributed to the fact that LN 2 machining provides better cooling and lubrication through substantial reduction in the cutting zone temperature.
NASA Astrophysics Data System (ADS)
Milawarni; Nurlaili; Ernayusnianti
2018-03-01
This research focuses on introducing a coffee husk as viable and efficient filler for enhancing physical and mechanical properties of Styrofoam based particleboard. Heat treatment method was adopted to produce the particleboard from the mixture of coffee husk (CH) with Styrofoam (PS). Styrofoam is material derived from polystyrene. The aim of this research is to get the appropriate weight composition between coffee husks with PS and to identify the physical and mechanical properties of the produced particleboard. The composition of coffee husk varies between 0-90%wt. The manufacture of particleboard i.e. coffee husk milled with size 20/10 mesh then soak with 10% NaOH for 2 hours, rinsed with clean water and dried and weight according to the composition. The mixture of CH and PS is inserted into mold and put into hot-press. The result shows from physical properties that density, water absorption and thick development test corresponding with SNI 03-2105-2006 standard, the mechanical properties shows MOR test meets the standard on the addition of CH 10-50%, while the MOE test has not meet the standard.
76 FR 53086 - Pipeline Safety: Safety of Gas Transmission Pipelines
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-25
... and external corrosion (subpart I of 49 CFR part 192). Pressure tests of new pipelines (subpart J of..., integrate and validate data (e.g., review of mill inspection reports, hydrostatic tests reports, pipe leaks... chemical properties, mill inspection reports, hydrostatic tests reports, coating type and condition, pipe...
Optimizing the Synthesis of Alumina Inserts Using Hot Isostatic Pressing (HIP)
NASA Astrophysics Data System (ADS)
Ariff, T. F.; Azhar, A. Z.; Sariff, M. N.; Rasid, S. N.; Zahari, S. Z.; Bahar, R.; Karim, M.; Nurul Amin, AKM
2018-01-01
Alumina or Aluminium Oxide (Al2O3) is well known for its high strength and hardness. Its low heat retention and low specific heat characteristics make it attractive to be used widely as a cutting tool for grinding, milling and turning processes. Various synthesis methods have been used for the purpose of enhancing the properties of the alumina inserts. However, the optimization process using Hot Isostatic Pressing (HIP) has not been performed. This research aims in finding the optimum parameters in synthesizing the alumina inserts (98Al2O3 1.6ZrO2 0.4MgO, 93Al2O3 6.4ZrO2 0.6MgO and 85Al2O3 14.5ZrO2 0.5MgO) using HIP at different temperatures (1200, 1250 and 1300°C) and sintering time (10, 30 and 60 minutes). Hardness, density, shrinkage and microstructure using SEM were analysed. The optimum sintering condition for the alumina insert was found in 98Al2O3 1.6ZrO2 0.4MgO sintered at 1300°C for 60 minutes for it exhibited the highest values of hardness (1917HV), density (3.95g/cm3), shrinkage (9.6%).
Abootalebian, Mehrdad; Karbasi, Maryam; Sadeghi, Maliheh; Abdinian, Mahnaz; Polikarpov, Igor
2017-10-01
This study investigated the effect of saffron nano-sizing on its the colour extraction yield. The whole stigma was ball-milled at three different times (10, 20 and 100 h), immediately or with a 24 h delay was submitted to absorption test, and then the colour extraction efficiency was determined. When stigma was milled for 100 h, its particle size was reduced to less than 20 nm, as shown by SEM and TEM images, and its extraction efficiency was considerably increased by 19.8% as compared with the stigma blended for 10 min. However with a 24 h delay between the end of milling and absorption test, the yield of colour extraction significantly decreased. The recommended milling conditions resulting in extraction efficiency of 16.2% (in comparison with stigma blended for 10 min) were determined to be the milling for 10 h with initial tendering prior to milling operation.
Prevalence of respiratory symptoms and disorders among rice mill workers in India.
Ghosh, Tirthankar; Gangopadhyay, Somnath; Das, Banibrata
2014-05-01
Lung function tests have become an integral part of assessment of pulmonary disease. Diseases of the respiratory system induced by occupational dusts are influenced by the duration of exposure. The aim of the study is to investigate the impairment of lung function and prevalence of respiratory symptoms among the rice mill workers. A total of 120 rice mill workers from three districts of Karnataka were included in this study. Fifty urban dwellers from the same socio-economic level were selected as controls. The study included clinical examination, assessment of respiratory symptoms, pulmonary function test, measurement of peak expiratory flow rate, absolute eosinophil count, ESR estimation, total IgE estimation and radiographic test. The present study has shown that the rice mill workers complained of several types of respiratory disorders like phlegm (40.8 %), dyspnea (44.2 %), chest tightness (26.7 %), cough (21.7 %), and nose irritation (27.5 %). Rice mill workers exposed to dust presented significantly (p < 0.05) lower levels of FVC (3.44 ± 0.11), FEV1 (2.73 ± 0.15) and PEFR (304.95 ± 28.79) than the controls. The rice mill workers are having significantly higher absolute eosinophil counts, total IgE and ESR than control groups. The hematological findings suggest that the harmful effects may be linked to both non-specific irritation and allergic responses to rice husk dust among rice mill workers. Dust exposure in the working environment affects the lung function values and increased the respiratory symptoms among the rice mill workers.
Post-harvest and post-milling changes in wheat grain and flour quality characteristics
USDA-ARS?s Scientific Manuscript database
Soft red winter (SRW) wheat grain immediately after harvest and flour after milling were stored for 26 weeks and analyzed for comprehensive milling and baking quality characteristics at different time points to examine the consistency of the quality test results. Increases in falling number (FN) of ...
46 CFR 50.25-3 - Manufacturer or mill certification.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Manufacturer or mill certification. 50.25-3 Section 50.25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL... issue a certificate or mill test report which shall report the results of chemical analysis and...
46 CFR 50.25-3 - Manufacturer or mill certification.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Manufacturer or mill certification. 50.25-3 Section 50.25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL... issue a certificate or mill test report which shall report the results of chemical analysis and...
46 CFR 50.25-3 - Manufacturer or mill certification.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Manufacturer or mill certification. 50.25-3 Section 50.25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL... issue a certificate or mill test report which shall report the results of chemical analysis and...
46 CFR 50.25-3 - Manufacturer or mill certification.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Manufacturer or mill certification. 50.25-3 Section 50.25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL... issue a certificate or mill test report which shall report the results of chemical analysis and...
46 CFR 50.25-3 - Manufacturer or mill certification.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Manufacturer or mill certification. 50.25-3 Section 50.25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL... issue a certificate or mill test report which shall report the results of chemical analysis and...
Development of a Tri-Axial Cutting Force Sensor for the Milling Process
Li, Yingxue; Zhao, Yulong; Fei, Jiyou; Zhao, You; Li, Xiuyuan; Gao, Yunxiang
2016-01-01
This paper presents a three-component fixed dynamometer based on a strain gauge, which reduces output errors produced by the cutting force imposed on different milling positions of the workpiece. A reformative structure of tri-layer cross beams is proposed, sensitive areas were selected, and corresponding measuring circuits were arranged to decrease the inaccuracy brought about by positional variation. To simulate the situation with a milling cutter moving on the workpiece and validate the function of reducing the output errors when the milling position changes, both static calibration and dynamic milling tests were implemented on different parts of the workpiece. Static experiment results indicate that with standard loads imposed, the maximal deviation between the measured forces and the standard inputs is 4.87%. The results of the dynamic milling test illustrate that with identical machining parameters, the differences in output variation between the developed sensor and standard dynamometer are no larger than 6.61%. Both static and dynamic experimental results demonstrate that the developed dynamometer is suitable for measuring milling force imposed on different positions of the workpiece, which shows potential applicability in machining a monitoring system. PMID:27007374
A study on rheological characteristics of roller milled fenugreek fractions.
Sakhare, Suresh D; Inamdar, Aashitosh A; Prabhasankar, P
2016-01-01
Fenugreek seeds were fractionated by roller milling to get various fractions. The roller milled fractions and whole fenugreek flour (WFF) were evaluated for the flow behavior and time-dependent flow properties using a rotational viscometer at the temperatures of 10-60 (0)C. The samples subjected to a programmed shear rate increase linearly from 0 to 300 s(-1) in 3 min and successive decrease linearly shear rate from 300 s(-1) to 0 in 3 min. The roller milled fractions and WFF paste exhibited non-Newtonian pseudoplastic behavior. Difference in hysteresis loop area was observed among the roller milled fractions and WFF, being more noticeable at lower temperatures. Power law and Casson models were used to predict flow properties of samples. The power law model described well the flow behavior of the roller milled fractions and WFF at temperatures tested. Except flour (FL) fraction, consistency coefficient, m, increased with the temperature both in the forward and backward measurements. The roller milled fractions and WFF exhibited rheopectic behavior that increased viscosity with increasing the shear speed and the temperature. For all the sample tested, initial shear stress increased with increase in shear rate and temperature.
Contamination risk of stable isotope samples during milling.
Isaac-Renton, M; Schneider, L; Treydte, K
2016-07-15
Isotope analysis of wood is an important tool in dendrochronology and ecophysiology. Prior to mass spectrometry analysis, wood must be homogenized, and a convenient method involves a ball mill capable of milling samples directly in sample tubes. However, sample-tube plastic can contaminate wood during milling, which could lead to biological misinterpretations. We tested possible contamination of whole wood and cellulose samples during ball-mill homogenization for carbon and oxygen isotope measurements. We used a multi-factorial design with two/three steel milling balls, two sample amounts (10 mg, 40 mg), and two milling times (5 min, 10 min). We further analyzed abrasion by milling empty tubes, and measured the isotope ratios of pure contaminants. A strong risk exists for carbon isotope bias through plastic contamination: the δ(13) C value of polypropylene deviated from the control by -6.77‰. Small fibers from PTFE filter bags used during cellulose extraction also present a risk as the δ(13) C value of this plastic deviated by -5.02‰. Low sample amounts (10 mg) showed highest contamination due to increased abrasion during milling (-1.34‰), which is further concentrated by cellulose extraction (-3.38‰). Oxygen isotope measurements were unaffected. A ball mill can be used to homogenize samples within test tubes prior to oxygen isotope analysis, but not prior to carbon or radiocarbon isotope analysis. There is still a need for a fast, simple and contamination-free sample preparation procedure. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Okamoto, Yuji; Harada, Yoshitomo; Ohta, Narumi; Takada, Kazunori; Sumiya, Masatomo
2016-09-01
We demonstrate that a SiO disproportionation reaction can be achieved simply by high energy mechanochemical milling. The planetary ball-milling of ZrO2 for a few minutes generated Si nano-crystals. Milling conditions including rotation speed, ball number, milling time, and type of ball material were able to control the oxidation states of Si. The ball-milled SiO powder was tested as an anode of a lithium battery. ZrO2 contamination from the vial and balls was eliminated by dipping the ball-milled SiO powder in (NH4)HSO4 molten salt and heating for 5 min. The disproportionated SiO powder showed characteristics comparable to those of a powder prepared by a conventional heating process taking several hours.
Air embolism after central venous catheterization.
Kashuk, J L; Penn, I
1984-09-01
Air embolism--the most dangerous complication of central venous catheterization--may occur in several ways. The most frequent is from disconnection of the catheter from the related intravenous tubing. An embolism may present with a sucking sound, tachypnea, air hunger, wheezing, hypotension and a "mill wheel" murmur. A later manifestation is severe pulmonary edema. In a review of 24 patients, the mortality was 50 per cent. Among the survivors, five (42 per cent) had neurologic damage. Immediate treatment includes placing the patient in the left lateral and Trendelenberg positions, administration of oxygen and aspiration of air from the heart. Cardiac massage and emergency cardiopulmonary bypass may be necessary. Most instances can be prevented by inserting the cannula with the patient in the Trendelenberg position, occluding the cannula hub except briefly while the catheter is inserted, fixation of the catheter hub to its connections and occlusive dressing over the track after removal of the catheter.
The Tool Life of Ball Nose end Mill Depending on the Different Types of Ramping
NASA Astrophysics Data System (ADS)
Vopát, Tomáš; Peterka, Jozef; Kováč, Martin
2014-12-01
The article deals with the cutting tool wear measurement process and tool life of ball nose end mill depending on upward ramping and downward ramping. The aim was to determine and compare the wear (tool life) of ball nose end mill for different types of copy milling operations, as well as to specify particular steps of the measurement process. In addition, we examined and observed cutter contact areas of ball nose end mill with machined material. For tool life test, DMG DMU 85 monoBLOCK 5-axis CNC milling machine was used. In the experiment, cutting speed, feed rate, axial depth of cut and radial depth of cut were not changed. The cutting tool wear was measured on Zoller Genius 3s universal measuring machine. The results show different tool life of ball nose end mills depending on the copy milling strategy.
Design and Development of a Three-Component Force Sensor for Milling Process Monitoring
Li, Yingxue; Zhao, Yulong; Fei, Jiyou; Qin, Yafei; Zhao, You; Cai, Anjiang; Gao, Song
2017-01-01
A strain-type three-component table dynamometer is presented in this paper, which reduces output errors produced by cutting forces imposed on the different milling positions of a workpiece. A sensor structure with eight parallel elastic beams is proposed, and sensitive regions and Wheastone measuring circuits are also designed in consideration of eliminating the influences of the eccentric forces. To evaluate the sensor decoupling performance, both of the static calibration and dynamic milling test were implemented in different positions of the workpiece. Static experiment results indicate that the maximal deviation between the measured forces and the standard inputs is 4.58%. Milling tests demonstrate that with same machining parameters, the differences of the measured forces between different milling positions derived by the developed sensor are no larger than 6.29%. In addition, the natural frequencies of the dynamometer are kept higher than 2585.5 Hz. All the measuring results show that as a strain-type dynamometer, the developed force sensor has an improved eccentric decoupling accuracy with natural frequencies not much decreased, which owns application potential in milling process monitoring. PMID:28441354
NASA Astrophysics Data System (ADS)
Bayraktar, S.; Hekimoglu, A. P.; Turgut, Y.; Haciosmanoglu, M.
2018-01-01
In this study, Al-35Zn alloy was produced by permanent mold casting. To investigate the cutting performance of uncoated and TiAlN coated carbide end mills on this alloy, a series of tests were carried out in the CNC vertical machining center at a constant cutting speed, feed rate and depth of cut. The results obtained from the tests showed that uncoated carbide end mill have lower cutting force and surface roughness than TiAlN coated carbide end mill. These observations are discussed in terms of the alloys properties, cutting tool surfaces, and friction and wear behavior between the cutting tool and the material.
Antisymmetric Wilson loops in N = 4 SYM beyond the planar limit
NASA Astrophysics Data System (ADS)
Gordon, James
2018-01-01
We study the 1/2 -BPS circular Wilson loop in the totally antisymmetric representation of the gauge group in N = 4 supersymmetric Yang-Mills. This observable is captured by a Gaussian matrix model with appropriate insertion. We compute the first 1 /N correction at leading order in 't Hooft coupling by means of the matrix model loop equations. Disagreement with the 1-loop effective action of the holographically dual D5-brane suggests the need to account for gravitational backreaction on the string theory side.
NASA Astrophysics Data System (ADS)
Yue, Zhihao; Zhou, Lang; Jin, Chenxin; Xu, Guojun; Liu, Liekai; Tang, Hao; Li, Xiaomin; Sun, Fugen; Huang, Haibin; Yuan, Jiren
2017-06-01
N-type silicon wafers with electrical resistivity of 0.001 Ω cm were ball-milled to powders and part of them was further mechanically crushed by sand-milling to smaller particles of nano-size. Both the sand-milled and ball-milled silicon powders were, respectively, mixed with graphite powder (silicon:graphite = 5:95, weight ratio) as anode materials for lithium ion batteries. Electrochemical measurements, including cycle and rate tests, present that anode using sand-milled silicon powder performed much better. The first discharge capacity of sand-milled silicon anode is 549.7 mAh/g and it is still up to 420.4 mAh/g after 100 cycles. Besides, the D50 of sand-milled silicon powder shows ten times smaller in particle size than that of ball-milled silicon powder, and they are 276 nm and 2.6 μm, respectively. In addition, there exist some amorphous silicon components in the sand-milled silicon powder excepting the multi-crystalline silicon, which is very different from the ball-milled silicon powder made up of multi-crystalline silicon only.
NASA Astrophysics Data System (ADS)
Vereschaka, Alexey; Mokritskii, Boris; Mokritskaya, Elena; Sharipov, Oleg; Oganyan, Maksim
2018-03-01
The paper deals with the challenges of the application of two-component end mills, which represent a combination of a carbide cutting part and a shank made of cheaper structural material. The calculations of strains and deformations of composite mills were carried out in comparison with solid carbide mills, with the use of the finite element method. The study also involved the comparative analysis of accuracy parameters of machining with monolithic mills and two-component mills with various shank materials. As a result of the conducted cutting tests in milling aluminum alloy with monolithic and two-component end mills with specially developed multilayer composite nano-structured coatings, it has been found that the use of such coatings can reduce strains and, correspondingly, deformations, which can improve the accuracy of machining. Thus, the application of two-component end mills with multilayer composite nano-structured coatings can provide a reduction in the cost of machining while maintaining or even improving the tool life and machining accuracy parameters.
NASA Technical Reports Server (NTRS)
Litvin, Faydor L.; Zhang, YI; Chen, Jui-Sheng
1991-01-01
Research was performed to develop a computer program that will: (1) simulate the meshing and bearing contact for face milled spiral beval gears with given machine tool settings; and (2) to obtain the output, some of the data is required for hydrodynamic analysis. It is assumed that the machine tool settings and the blank data will be taken from the Gleason summaries. The theoretical aspects of the program are based on 'Local Synthesis and Tooth Contact Analysis of Face Mill Milled Spiral Bevel Gears'. The difference between the computer programs developed herein and the other one is as follows: (1) the mean contact point of tooth surfaces for gears with given machine tool settings must be determined iteratively, while parameters (H and V) are changed (H represents displacement along the pinion axis, V represents the gear displacement that is perpendicular to the plane drawn through the axes of the pinion and the gear of their initial positions), this means that when V differs from zero, the axis of the pionion and the gear are crossed but not intersected; (2) in addition to the regular output data (transmission errors and bearing contact), the new computer program provides information about the contacting force for each contact point and the sliding and the so-called rolling velocity. The following topics are covered: (1) instructions for the users as to how to insert the input data; (2) explanations regarding the output data; (3) numerical example; and (4) listing of the program.
4D and 2D superconformal index with surface operator
NASA Astrophysics Data System (ADS)
Nakayama, Yu
2011-08-01
We study the superconformal index of the mathcal{N} = 4 super-Yang-Milles theory on S 3 × S 1 with the half BPS superconformal surface operator (defect) inserted at the great circle of S 3. The half BPS superconformal surface operators preserve the same supersymmetry as well as the symmetry of the chemical potential used in the definition of the superconformal index, so the structure and the parameterization of the superconformal index remain unaffected by the presence of the surface operator. On the surface defect, a two-dimensional (4, 4) superconformal field theory resides, and the four-dimensional super-conformal index may be regarded as a superconformal index of the two-dimensional (4, 4) superconformal field theory coupled with the four-dimensional bulk system. We construct the matrix model that computes the superconformal index with the surface operator when it couples with the bulk mathcal{N} = 4 super-Yang-Milles theory through the defect hypermultiplets on it.
USDA-ARS?s Scientific Manuscript database
Paulownia wood flour (PWF), a byproduct of milling lumber, was tested as bio-filler with polylactic acid (PLA). Paulownia wood (PW) shavings were milled and separated into particle fractions and then blended with PLA with a single screw extruder. Mechanical and thermal properties were tested. Dif...
Effect of High Speed Sintering on the Properties of Zirconia Oxide Materials
2018-03-22
Beam-shaped specimens were designed using an Omnicam (Version 4.4.4; Dentsply Sirona) and milled from CAD/CAM blocks using a MCXL milling unit...8217. . . . . ··~· . IPS e.maxCAD CAD/CAM: block with milled beam RESUE.TS No significant differences were found for any of the properties tested between the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundberg, Mattias, E-mail: mattias.lundberg@liu.se
Machining of austenitic stainless steels can result in different surface integrities and different machining process parameters will have a great impact on the component fatigue life. Understanding how machining processes affect the cyclic behaviour and microstructure are of outmost importance in order to improve existing and new life estimation models. Milling and electrical discharge machining (EDM) have been used to manufacture rectangular four-point bend fatigue test samples; subjected to high cycle fatigue. Before fatigue testing, surface integrity characterisation of the two surface conditions was conducted using scanning electron microscopy, surface roughness, residual stress profiles, and hardness profiles. Differences in cyclicmore » behaviour were observed between the two surface conditions by the fatigue testing. The milled samples exhibited a fatigue limit. EDM samples did not show the same behaviour due to ratcheting. Recrystallized nano sized grains were identified at the severely plastically deformed surface of the milled samples. Large amounts of bent mechanical twins were observed ~ 5 μm below the surface. Grain shearing and subsequent grain rotation from milling bent the mechanical twins. EDM samples showed much less plastic deformation at the surface. Surface tensile residual stresses of ~ 500 MPa and ~ 200 MPa for the milled and EDM samples respectively were measured. - Highlights: •Milled samples exhibit fatigue behaviour, but not EDM samples. •Four-point bending is not suitable for materials exhibiting pronounced ratcheting. •LAGB density can be used to quantitatively measure plastic deformation. •Grain shearing and rotation result in bent mechanical twins. •Nano sized grains evolve due to the heat of the operation.« less
Modeling of Surface Geometric Structure State After Integratedformed Milling and Finish Burnishing
NASA Astrophysics Data System (ADS)
Berczyński, Stefan; Grochała, Daniel; Grządziel, Zenon
2017-06-01
The article deals with computer-based modeling of burnishing a surface previously milled with a spherical cutter. This method of milling leaves traces, mainly asperities caused by the cutting crossfeed and cutter diameter. The burnishing process - surface plastic treatment - is accompanied by phenomena that take place right in the burnishing ball-milled surface contact zone. The authors present the method for preparing a finite element model and the methodology of tests for the assessment of height parameters of a surface geometrical structure (SGS). In the physical model the workpieces had a cuboidal shape and these dimensions: (width × height × length) 2×1×4.5 mm. As in the process of burnishing a cuboidal workpiece is affected by plastic deformations, the nonlinearities of the milled item were taken into account. The physical model of the process assumed that the burnishing ball would be rolled perpendicularly to milling cutter linear traces. The model tests included the application of three different burnishing forces: 250 N, 500 N and 1000 N. The process modeling featured the contact and pressing of a ball into the workpiece surface till the desired force was attained, then the burnishing ball was rolled along the surface section of 2 mm, and the burnishing force was gradually reduced till the ball left the contact zone. While rolling, the burnishing ball turned by a 23° angle. The cumulative diagrams depict plastic deformations of the modeled surfaces after milling and burnishing with defined force values. The roughness of idealized milled surface was calculated for the physical model under consideration, i.e. in an elementary section between profile peaks spaced at intervals of crossfeed passes, where the milling feed fwm = 0.5 mm. Also, asperities after burnishing were calculated for the same section. The differences of the obtained values fall below 20% of mean values recorded during empirical experiments. The adopted simplification in after-milling SGS modeling enables substantial acceleration of the computing process. There is a visible reduction of the Ra parameter value for milled and burnished surfaces as the burnishing force rises. The tests determined an optimal burnishing force at a level of 500 N (lowest Ra = 0.24 μm). Further increase in the value of burnishing force turned out not to affect the surface roughness, which is consistent with the results obtained from experimental studies.
Effects of Ultrasonics-Assisted Face Milling on Surface Integrity and Fatigue Life of Ni-Alloy 718
NASA Astrophysics Data System (ADS)
Suárez, Alfredo; Veiga, Fernando; de Lacalle, Luis N. López; Polvorosa, Roberto; Lutze, Steffen; Wretland, Anders
2016-11-01
This work investigates the effects of ultrasonic vibration-assisted milling on important aspects such us material surface integrity, tool wear, cutting forces and fatigue resistance. As an alternative to natural application of ultrasonic milling in brittle materials, in this study, ultrasonics have been applied to a difficult-to-cut material, Alloy 718, very common in high-temperature applications. Results show alterations in the sub-superficial part of the material which could influence fatigue resistance of the material, as it has been observed in a fatigue test campaign of specimens obtained with the application of ultrasonic milling in comparison with another batch obtained applying conventional milling. Tool wear pattern was found to be very similar for both milling technologies, concluding the study with the analysis of cutting forces, exhibiting certain improvement in case of the application of ultrasonic milling with a more stable evolution.
Biomechanical properties of wheat grains: the implications on milling.
Hourston, James E; Ignatz, Michael; Reith, Martin; Leubner-Metzger, Gerhard; Steinbrecher, Tina
2017-01-01
Millennia of continuous innovation have driven ever increasing efficiency in the milling process. Mechanically characterizing wheat grains and discerning the structure and function of the wheat bran layers can contribute to continuing innovation. We present novel shear force and puncture force testing regimes to characterize different wheat grain cultivars. The forces endured by wheat grains during the milling process can be quantified, enabling us to measure the impact of commonly applied grain pretreatments, such as microwave heating, extended tempering, enzyme and hormone treatments on grains of different 'hardness'. Using these methods, we demonstrate the importance of short tempering phases prior to milling and identify ways in which our methods can detect differences in the maximum force, energy and breaking behaviours of hard and soft grain types. We also demonstrate for the first time, endosperm weakening in wheat, through hormone stratification on single bran layers. The modern milling process is highly refined, meaning that small, cultivar specific, adjustments can result in large increases in downstream profits. We believe that methods such as these, which enable rapid testing of milling pretreatments and material properties can help to drive an innovation process that has been core to our industrial efforts since prehistory. © 2017 The Authors.
Biomechanical properties of wheat grains: the implications on milling
Reith, Martin
2017-01-01
Millennia of continuous innovation have driven ever increasing efficiency in the milling process. Mechanically characterizing wheat grains and discerning the structure and function of the wheat bran layers can contribute to continuing innovation. We present novel shear force and puncture force testing regimes to characterize different wheat grain cultivars. The forces endured by wheat grains during the milling process can be quantified, enabling us to measure the impact of commonly applied grain pretreatments, such as microwave heating, extended tempering, enzyme and hormone treatments on grains of different ‘hardness’. Using these methods, we demonstrate the importance of short tempering phases prior to milling and identify ways in which our methods can detect differences in the maximum force, energy and breaking behaviours of hard and soft grain types. We also demonstrate for the first time, endosperm weakening in wheat, through hormone stratification on single bran layers. The modern milling process is highly refined, meaning that small, cultivar specific, adjustments can result in large increases in downstream profits. We believe that methods such as these, which enable rapid testing of milling pretreatments and material properties can help to drive an innovation process that has been core to our industrial efforts since prehistory. PMID:28100826
Edge crack sensitivity of lightweight materials under different load conditions
NASA Astrophysics Data System (ADS)
Tsoupis, I.; Merklein, M.
2016-11-01
This study addresses the analysis of edge crack sensitivity of DP800 steel and AA5182 aluminum alloy in dependency of punching and machining operation as well as load case of subsequent forming. The inserting of a round hole by punching with defined punch-to- die-clearance, milling and drilling is compared. Subsequent forming is performed by standardized hole expansion test and by Nakajima-tests with three different specimen geometries. Local strain distribution at the surface for Nakajima-tests is measured by optical strain measurement technique and investigated in order to evaluate local deformation before failure. Additionally, resulting hole expansion ratio λ is determined. Significant higher X as well as local strain values ε max are achieved by machined holes. This is directly coupled to higher local formability and stretchability for both materials. Furthermore, the load condition has a strong impact on the edge crack sensitivity of the material. Prior failure is observed with changing stress conditions using different specimen geometries also influencing the reachable maximum failure strain. Higher edge crack sensitivity is observed for DP800, which is in good accordance to the material properties in terms of ductility and strength. These data in dependency of the process parameter can be used for the design of automotive components.
Rani, Sapna; Verma, Mahesh; Gill, Shubhra; Gupta, Rekha
2016-01-01
Background/Purpose: The aim of this study was to compare the shear bond strength of computer aided design/computer aided machined ceramic (CAD/CAM), pressable ceramic, and milled metal implant copings on abutment and the effect of surface conditioning on bonding strength. Materials and Methods: A total of 90 test samples were fabricated on three titanium abutments. Among 90 test samples, 30 copings were fabricated by CAD/CAM, 30 by pressable, and 30 by milling of titanium metal. These 30 test samples in each group were further subdivided equally for surface treatment. Fifteen out of 30 test samples in each group were surface conditioned with airborne particle abrasion. All the 90 test samples were luted on abutment with glass ionomer cement. Bonding strength was evaluated for all the samples using universal testing machine at a crosshead speed of 5 mm/min. The results obtained were compared and evaluated using one-way ANOVA with post-hoc and unpaired t-test at a significance level of 0.05. Results: The mean difference for CAD/CAM surface conditioned subgroup was 1.28 ± 0.12, for nonconditioned subgroup was 1.20 ± 0.11. The mean difference for pressable surface conditioned subgroup was 1.18 ± 0.04, and for nonconditioned subgroup was 0.75 ± 0.28. The mean difference for milled metal surface conditioned subgroup was 2.57 ± 0.58, and for nonconditioned subgroup was 1.49 ± 0.15. Conclusions: On comparison of bonding strength, milled metal copings had an edge over the other two materials, and surface conditioning increased the bond strength. PMID:27141163
Chung, Tien-Kan; Yeh, Po-Chen; Lee, Hao; Lin, Cheng-Mao; Tseng, Chia-Yung; Lo, Wen-Tuan; Wang, Chieh-Min; Wang, Wen-Chin; Tu, Chi-Jen; Tasi, Pei-Yuan; Chang, Jui-Wen
2016-02-23
An attachable electromagnetic-energy-harvester driven wireless vibration-sensing system for monitoring milling-processes and cutter-wear/breakage-conditions is demonstrated. The system includes an electromagnetic energy harvester, three single-axis Micro Electro-Mechanical Systems (MEMS) accelerometers, a wireless chip module, and corresponding circuits. The harvester consisting of magnets with a coil uses electromagnetic induction to harness mechanical energy produced by the rotating spindle in milling processes and consequently convert the harnessed energy to electrical output. The electrical output is rectified by the rectification circuit to power the accelerometers and wireless chip module. The harvester, circuits, accelerometer, and wireless chip are integrated as an energy-harvester driven wireless vibration-sensing system. Therefore, this completes a self-powered wireless vibration sensing system. For system testing, a numerical-controlled machining tool with various milling processes is used. According to the test results, the system is fully self-powered and able to successfully sense vibration in the milling processes. Furthermore, by analyzing the vibration signals (i.e., through analyzing the electrical outputs of the accelerometers), criteria are successfully established for the system for real-time accurate simulations of the milling-processes and cutter-conditions (such as cutter-wear conditions and cutter-breaking occurrence). Due to these results, our approach can be applied to most milling and other machining machines in factories to realize more smart machining technologies.
Chung, Tien-Kan; Yeh, Po-Chen; Lee, Hao; Lin, Cheng-Mao; Tseng, Chia-Yung; Lo, Wen-Tuan; Wang, Chieh-Min; Wang, Wen-Chin; Tu, Chi-Jen; Tasi, Pei-Yuan; Chang, Jui-Wen
2016-01-01
An attachable electromagnetic-energy-harvester driven wireless vibration-sensing system for monitoring milling-processes and cutter-wear/breakage-conditions is demonstrated. The system includes an electromagnetic energy harvester, three single-axis Micro Electro-Mechanical Systems (MEMS) accelerometers, a wireless chip module, and corresponding circuits. The harvester consisting of magnets with a coil uses electromagnetic induction to harness mechanical energy produced by the rotating spindle in milling processes and consequently convert the harnessed energy to electrical output. The electrical output is rectified by the rectification circuit to power the accelerometers and wireless chip module. The harvester, circuits, accelerometer, and wireless chip are integrated as an energy-harvester driven wireless vibration-sensing system. Therefore, this completes a self-powered wireless vibration sensing system. For system testing, a numerical-controlled machining tool with various milling processes is used. According to the test results, the system is fully self-powered and able to successfully sense vibration in the milling processes. Furthermore, by analyzing the vibration signals (i.e., through analyzing the electrical outputs of the accelerometers), criteria are successfully established for the system for real-time accurate simulations of the milling-processes and cutter-conditions (such as cutter-wear conditions and cutter-breaking occurrence). Due to these results, our approach can be applied to most milling and other machining machines in factories to realize more smart machining technologies. PMID:26907297
Implementing a prototyping network for injection moulded imaging lenses in Finland
NASA Astrophysics Data System (ADS)
Keränen, K.; Mäkinen, J.-T.; Pääkkönen, E. J.; Koponen, M.; Karttunen, M.; Hiltunen, J.; Karioja, P.
2005-10-01
A network for prototyping imaging lenses using injection moulding was established in Finland. The network consists of several academic and industrial partners capable of designing, processing and characterising imaging lenses produced by injection moulding technology. In order to validate the operation of the network a demonstrator lens was produced. The process steps included in the manufacturing were lens specification, designing and modelling, material selection, mould tooling, moulding process simulation, injection moulding and characterisation. A magnifying imaging singlet lens to be used as an add-on in a camera phone was selected as a demonstrator. The design of the add-on lens proved to be somewhat challenging, but a double aspheric singlet lens design fulfilling nearly the requirement specification was produced. In the material selection task the overall characteristics profile of polymethyl methacrylate (PMMA) material was seen to be the most fitting to the pilot case. It is a low cost material with good moulding properties and therefore it was selected as a material for the pilot lens. Lens mould design was performed using I-DEAS and tested by using MoldFlow 3D injection moulding simulation software. The simulations predicted the achievable lens quality in the processing, when using a two-cavity mould design. First cavity was tooled directly into the mould plate and the second cavity was made by tooling separate insert pieces for the mould. Mould material was steel and the inserts were made from Moldmax copper alloy. Parts were tooled with high speed milling machines. Insert pieces were hand polished after tooling. Prototype lenses were injection moulded using two PMMA grades, namely 6N and 7N. Different process parameters were also experimented in the injection moulding test runs. Prototypes were characterised by measuring mechanical dimensions, surface profile, roughness and MTF of the lenses. Characterisations showed that the lens surface RMS roughness was 30-50 nm and the profile deviation was 5 μm from the design at a distance of 0.3 mm from the lens vertex. These manufacturing defects caused that the measured MTF values were lower than designed. The lens overall quality, however, was adequate to demonstrate the concept successfully. Through the implementation of the demonstrator lens we could test effectively different stages of the manufacturing process and get information about process component weight and risk factors and validate the overall performance of the network.
Kianmajd, Babak; Carter, David; Soshi, Masakazu
2016-10-01
Robotic total hip arthroplasty is a procedure in which milling operations are performed on the femur to remove material for the insertion of a prosthetic implant. The robot performs the milling operation by following a sequential list of tool motions, also known as a toolpath, generated by a computer-aided manufacturing (CAM) software. The purpose of this paper is to explain a new toolpath force prediction algorithm that predicts cutting forces, which results in improving the quality and safety of surgical systems. With a custom macro developed in the CAM system's native application programming interface, cutting contact patch volume was extracted from CAM simulations. A time domain cutting force model was then developed through the use of a cutting force prediction algorithm. The second portion validated the algorithm by machining a hip canal in simulated bone using a CNC machine. Average cutting forces were measured during machining using a dynamometer and compared to the values predicted from CAM simulation data using the proposed method. The results showed the predicted forces matched the measured forces in both magnitude and overall pattern shape. However, due to inconsistent motion control, the time duration of the forces was slightly distorted. Nevertheless, the algorithm effectively predicted the forces throughout an entire hip canal procedure. This method provides a fast and easy technique for predicting cutting forces during orthopedic milling by utilizing data within a CAM software.
System technology for laser-assisted milling with tool integrated optics
NASA Astrophysics Data System (ADS)
Hermani, Jan-Patrick; Emonts, Michael; Brecher, Christian
2013-02-01
High strength metal alloys and ceramics offer a huge potential for increased efficiency (e. g. in engine components for aerospace or components for gas turbines). However, mass application is still hampered by cost- and time-consuming end-machining due to long processing times and high tool wear. Laser-induced heating shortly before machining can reduce the material strength and improve machinability significantly. The Fraunhofer IPT has developed and successfully realized a new approach for laser-assisted milling with spindle and tool integrated, co-rotating optics. The novel optical system inside the tool consists of one deflection prism to position the laser spot in front of the cutting insert and one focusing lens. Using a fiber laser with high beam quality the laser spot diameter can be precisely adjusted to the chip size. A high dynamic adaption of the laser power signal according to the engagement condition of the cutting tool was realized in order not to irradiate already machined work piece material. During the tool engagement the laser power is controlled in proportion to the current material removal rate, which has to be calculated continuously. The needed geometric values are generated by a CAD/CAM program and converted into a laser power signal by a real-time controller. The developed milling tool with integrated optics and the algorithm for laser power control enable a multi-axis laser-assisted machining of complex parts.
Researchers' Bibliography for Raven's Progressive Matrices and Mill Hill Vocabulary Scales.
ERIC Educational Resources Information Center
Court, J. H., Comp.
This annotated bibliography enables researchers who are using Raven's Progressive Matrices or the Mill Hill Vocabulary Scales to become familiar with other work that used these tests. The bibliography derives from Raven's own collection of sources, updated to the end of 1971. The major division of material is by tests rather than subject areas;…
Trueness of four different milling procedures used in dental CAD/CAM systems.
Kirsch, Corinna; Ender, Andreas; Attin, Thomas; Mehl, Albert
2017-03-01
Milling is a crucial step in producing restorations using computer-aided design and computer-aided manufacturing (CAD/CAM) systems. In this study the trueness of currently available milling devices was evaluated. Thirty clinical cases (ten inlays, ten crowns, ten onlays) were milled from ceramic blocks using four different milling approaches: five axis with IMES CORiTEC 450i, four axis with CEREC MCXL, four axis with CEREC MCXL-EF and five axis with inLab MCX5. The milled restorations were scanned and the occlusal and inner surfaces compared to the originally calculated 3D surface using difference analysis software. The (90-10 %) / 2 percentile of the distances were calculated and analysed using one-way ANOVA with the post hoc Scheffé test (α = 0.05). Chipping of marginal areas were visually examined and analysed using one-way ANOVA with a post hoc Tamhane test (α = 0.05). At inner surfaces, the milling trueness of IMES (33.9 ± 16.3 μm), X5 (32.3 ± 9.7 μm) and MCXL-EF (34.4 ± 7.5 μm) was significantly better (p < 0.001) than that of MCXL (62.1 ± 17.1 μm). At occlusal surfaces, MCXL-EF (25.7 ± 9.3 μm) showed significant higher accuracy (p < 0.001) than MCXL (48.7 ± 23.3 μm) and X5 (40.9 ± 20.4 μm). IMES produced the most chipping (p < 0.001). Five-axis milling devices yield high trueness. MCXL-EF is competitive and may allow chairside fabrication with good milling results. Accurate milling is required for well-fitting restorations and thereby requires fewer manual finishing steps, yields smaller marginal gaps, resistance to secondary caries and longevity of restorations.
37. DETAIL OF CYANIDE LEACHING TANK DRAIN DOOR AND PIPING ...
37. DETAIL OF CYANIDE LEACHING TANK DRAIN DOOR AND PIPING SYSTEM. NOTE SPIGOT UNDER BOARD AT UPPER LEFT INSERTS INTO HOLE IN PIPE AT BOTTOM OF FRAME. CYANIDE SOLUTION WAS PUMPED INTO THE TANKS AND THE PREGNANT SOLUTION DRAINED OUT OF THE TANKS THROUGH THIS PIPE, AND BACK INTO A SEPARATE HOLDING TANK ON THE EAST SIDE OF THE MILL. TAILINGS WERE REMOVED FROM THE TANKS THROUGH THE ROUND DRAIN DOOR IN THE BOTTOM OF THE TANK (MISSING) SEEN AT TOP CENTER. - Skidoo Mine, Park Route 38 (Skidoo Road), Death Valley Junction, Inyo County, CA
The study on dynamic properties of monolithic ball end mills with various slenderness
NASA Astrophysics Data System (ADS)
Wojciechowski, Szymon; Tabaszewski, Maciej; Krolczyk, Grzegorz M.; Maruda, Radosław W.
2017-10-01
The reliable determination of modal mass, damping and stiffness coefficient (modal parameters) for the particular machine-toolholder-tool system is essential for the accurate estimation of vibrations, stability and thus the machined surface finish formed during the milling process. Therefore, this paper focuses on the analysis of ball end mill's dynamical properties. The tools investigated during this study are monolithic ball end mills with different slenderness values, made of coated cemented carbide. These kinds of tools are very often applied during the precise milling of curvilinear surfaces. The research program included the impulse test carried out for the investigated tools clamped in the hydraulic toolholder. The obtained modal parameters were further applied in the developed tool's instantaneous deflection model, in order to estimate the tool's working part vibrations during precise milling. The application of the proposed dynamics model involved also the determination of instantaneous cutting forces on the basis of the mechanistic approach. The research revealed that ball end mill's slenderness can be considered as an important milling dynamics and machined surface quality indicator.
1. Credit WCT. Original 2 1/4" x 2 1/4" color ...
1. Credit WCT. Original 2- 1/4" x 2- 1/4" color negative is housed in the JPL Photography Laboratory, Pasadena, California. Photo shows John Morrow in charge of milling operations on coupons ("dogbones") of propellant on an Index milling machine. Coupons were milled to precise dimensions for tensile tests. Note that two sprinkler heads have been placed in very close proximity to the milling table for fire suppression purposes (JPL negative no. JPL-10283AC, 27 January 1989) - Jet Propulsion Laboratory Edwards Facility, Preparation Building, Edwards Air Force Base, Boron, Kern County, CA
NASA Astrophysics Data System (ADS)
Bączek, Elżbieta; Konstanty, Janusz; Romański, Andrzej; Podsiadło, Marcin; Cyboroń, Jolanta
2018-03-01
In this work, Fe-Mn-Cu-Sn-C alloys were prepared by means of powder metallurgy (PM). Powder mixtures were ball-milled for 8, 30 and 120 h and densified to < 1% porosity using spark plasma sintering (SPS) at 900 °C and 35 MPa. After consolidation, all samples of the Fe alloys were characterized by x-ray diffraction (XRD), scanning electron microscopy (SEM), hardness and flexural strength tests. Resistance to abrasive wear was evaluated in both three-body abrasion and two-body abrasion tests. The SEM observations revealed an evident dependence of grain size and microstructural homogeneity on milling time. The XRD analysis showed a marked increase in austenite content in the as-sintered specimens with milling time. Although the proportion of deformation-induced martensite was small, the strengthening effect of abrasion on the subsurface layer of the investigated alloys was clearly indicated by Knoop hardness measurements.
Development and testing of aluminum micro channel heat sink
NASA Astrophysics Data System (ADS)
Kumaraguruparan, G.; Sornakumar, T.
2010-06-01
Microchannel heat sinks constitute an innovative cooling technology for the removal of a large amount of heat from a small area and are suitable for electronics cooling. In the present work, Tool Steel D2 grade milling slitting saw type plain milling cutter is fabricated The microchannels are machined in aluminum work pieces to form the microchannel heat sink using the fabricated milling cutter in an horizontal milling machine. A new experimental set-up is fabricated to conduct the tests on the microchannel heat sink. The heat carried by the water increases with mass flow rate and heat input. The heat transfer coefficient and Nusselt number increases with mass flow rate and increased heat input. The pressure drop increases with Reynolds number and decreases with input heat. The friction factor decreases with Reynolds number and decreases with input heat. The thermal resistance decreases with pumping power and decreases with input heat.
Technical Note: Computer-Manufactured Inserts for Prosthetic Sockets
Sanders, Joan E.; McLean, Jake B.; Cagle, John C.; Gardner, David W.; Allyn, Katheryn J.
2016-01-01
The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant’s test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11 mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03 mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. PMID:27212209
Experimental evaluation of tool run-out in micro milling
NASA Astrophysics Data System (ADS)
Attanasio, Aldo; Ceretti, Elisabetta
2018-05-01
This paper deals with micro milling cutting process focusing the attention on tool run-out measurement. In fact, among the effects of the scale reduction from macro to micro (i.e., size effects) tool run-out plays an important role. This research is aimed at developing an easy and reliable method to measure tool run-out in micro milling based on experimental tests and an analytical model. From an Industry 4.0 perspective this measuring strategy can be integrated into an adaptive system for controlling cutting forces, with the objective of improving the production quality, the process stability, reducing at the same time the tool wear and the machining costs. The proposed procedure estimates the tool run-out parameters from the tool diameter, the channel width, and the phase angle between the cutting edges. The cutting edge phase measurement is based on the force signal analysis. The developed procedure has been tested on data coming from micro milling experimental tests performed on a Ti6Al4V sample. The results showed that the developed procedure can be successfully used for tool run-out estimation.
Characterization of IS1515, a Functional Insertion Sequence in Streptococcus pneumoniae
Muñoz, Rosario; López, Rubens; García, Ernesto
1998-01-01
We describe the characterization of a new insertion sequence, IS1515, identified in the genome of Streptococcus pneumoniae I41R, an unencapsulated mutant isolated many years ago (R. Austrian, H. P. Bernheimer, E. E. B. Smith, and G. T. Mills, J. Exp. Med. 110:585–602, 1959). A copy of this element located in the cap1EI41R gene was sequenced. The 871-bp-long IS1515 element possesses 12-bp perfect inverted repeats and generates a 3-bp target duplication upon insertion. The IS encodes a protein of 271 amino acid residues similar to the putative transposases of other insertion sequences, namely IS1381 from S. pneumoniae, ISL2 from Lactobacillus helveticus, IS702 from the cyanobacterium Calothrix sp. strain PCC 7601, and IS112 from Streptomyces albus G. IS1515 appears to be present in the genome of most type 1 pneumococci in a maximum of 13 copies, although it has also been found in the chromosome of pneumococcal isolates belonging to other serotypes. We have found that the unencapsulated phenotype of strain I41R is the result of both the presence of an IS1515 copy and a frameshift mutation in the cap1EI41R gene. Precise excision of the IS was observed in the type 1 encapsulated transformants isolated in experiments designed to repair the frameshift. These results reveal that IS1515 behaves quite differently from other previously described pneumococcal insertion sequences. Several copies of IS1515 were also able to excise and move to another locations in the chromosome of S. pneumoniae. To our knowledge, this is the first report of a functional IS in pneumococcus. PMID:9580131
NASA Astrophysics Data System (ADS)
Adesta, Erry Yulian T.; Riza, Muhammad; Avicena
2018-03-01
Tool wear prediction plays a significant role in machining industry for proper planning and control machining parameters and optimization of cutting conditions. This paper aims to investigate the effect of tool path strategies that are contour-in and zigzag tool path strategies applied on tool wear during pocket milling process. The experiments were carried out on CNC vertical machining centre by involving PVD coated carbide inserts. Cutting speed, feed rate and depth of cut were set to vary. In an experiment with three factors at three levels, Response Surface Method (RSM) design of experiment with a standard called Central Composite Design (CCD) was employed. Results obtained indicate that tool wear increases significantly at higher range of feed per tooth compared to cutting speed and depth of cut. This result of this experimental work is then proven statistically by developing empirical model. The prediction model for the response variable of tool wear for contour-in strategy developed in this research shows a good agreement with experimental work.
Greven, Marcus; Wismeijer, Daniel
2017-01-01
PURPOSE To integrate extra-oral facial scanning information with CAD/CAM complete dentures to immediately rehabilitate terminal dentition. MATERIALS AND METHODS Ten patients with terminal dentition scheduled for total extraction and immediate denture placement were recruited for this study. The patients were submitted to a facial scanning procedure using the in-office PritiMirror scanner with bite registration records in-situ. Definitive stone cast models and bite records were subsequently submitted to a lab scanning procedure using the lab scanner (iSeries DWOS; Dental Wings). The scanned models were used to create a virtual teeth setup of a complete denture. Using the intra-oral bite records as a reference, the virtual setup was incorporated in the facial scan thereby facilitating a virtual clinical evaluation (teeth try-in) phase. After applying necessary adjustments, the virtual setup was submitted to a CAM procedure where a 5-axis industrial milling machine (M7 CNC; Darton AG General) was used to fabricate a full-milled PMMA immediate provisional prosthesis. RESULTS Total extractions were performed, the dentures were immediately inserted, and subjective clinical fit was evaluated. The immediate provisional prostheses were inserted and clinical fit, occlusion/articulation, and esthetics were subjectively assessed; the results were deemed satisfactory. All provisional prostheses remained three months in function with no notable technical complications. CONCLUSION Ten patients with terminal dentition were treated using a complete digital approach to fabricate complete dentures using CAD/CAM technology. The proposed technique has the potential to accelerate the rehabilitation procedure starting from immediate denture to final implant-supported prosthesis leading to more predictable functional and aesthetics outcomes. PMID:29142646
NASA Astrophysics Data System (ADS)
Argyropoulos, Theodoros; Catalan-Lasheras, Nuria; Grudiev, Alexej; Mcmonagle, Gerard; Rodriguez-Castro, Enrique; Syrachev, Igor; Wegner, Rolf; Woolley, Ben; Wuensch, Walter; Zha, Hao; Dolgashev, Valery; Bowden, Gorden; Haase, Andrew; Lucas, Thomas Geoffrey; Volpi, Matteo; Esperante-Pereira, Daniel; Rajamäki, Robin
2018-06-01
A prototype 11.994 GHz, traveling-wave accelerating structure for the Compact Linear Collider has been built, using the novel technique of assembling the structure from milled halves. The use of milled halves has many advantages when compared to a structure made from individual disks. These include the potential for a reduction in cost, because there are fewer parts, as well as a greater freedom in choice of joining technology because there are no rf currents across the halves' joint. Here we present the rf design and fabrication of the prototype structure, followed by the results of the high-power test and post-test surface analysis. During high-power testing the structure reached an unloaded gradient of 100 MV /m at a rf breakdown rate of less than 1.5 ×10-5 breakdowns /pulse /m with a 200 ns pulse. This structure has been designed for the CLIC testing program but construction from halves can be advantageous in a wide variety of applications.
Ballistic Testing for Interceptor Body Armor Inserts Needs Improvement
2011-08-01
030, “Ballistic Testing and Product Quality Surveillance for the Interceptor Body Armor - Vest Components Need Improvement,” January 3, 2011. This...Body Armor Ballistic Inserts Interceptor Body Armor (IBA) is a modular body armor system that consists of an outer tactical vest , ballistic inserts...altitude tests was because the ceramic ballistic inserts are solid structures that are not sensitive to reduced pressure and moisture. PM SEQ offered no
High productivity machining of holes in Inconel 718 with SiAlON tools
NASA Astrophysics Data System (ADS)
Agirreurreta, Aitor Arruti; Pelegay, Jose Angel; Arrazola, Pedro Jose; Ørskov, Klaus Bonde
2016-10-01
Inconel 718 is often employed in aerospace engines and power generation turbines. Numerous researches have proven the enhanced productivity when turning with ceramic tools compared to carbide ones, however there is considerably less information with regard to milling. Moreover, no knowledge has been published about machining holes with this type of tools. Additional research on different machining techniques, like for instance circular ramping, is critical to expand the productivity improvements that ceramics can offer. In this a 3D model of the machining and a number of experiments with SiAlON round inserts have been carried out in order to evaluate the effect of the cutting speed and pitch on the tool wear and chip generation. The results of this analysis show that three different types of chips are generated and also that there are three potential wear zones. Top slice wear is identified as the most critical wear type followed by the notch wear as a secondary wear mechanism. Flank wear and adhesion are also found in most of the tests.
Technical note: Computer-manufactured inserts for prosthetic sockets.
Sanders, Joan E; McLean, Jake B; Cagle, John C; Gardner, David W; Allyn, Katheryn J
2016-08-01
The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant's test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method.
Jeong, Yoo-Geum; Lee, Wan-Sun; Lee, Kyu-Bok
2018-06-01
To evaluate the accuracy of a model made using the computer-aided design/computer-aided manufacture (CAD/CAM) milling method and 3D printing method and to confirm its applicability as a work model for dental prosthesis production. First, a natural tooth model (ANA-4, Frasaco, Germany) was scanned using an oral scanner. The obtained scan data were then used as a CAD reference model (CRM), to produce a total of 10 models each, either using the milling method or the 3D printing method. The 20 models were then scanned using a desktop scanner and the CAD test model was formed. The accuracy of the two groups was compared using dedicated software to calculate the root mean square (RMS) value after superimposing CRM and CAD test model (CTM). The RMS value (152±52 µm) of the model manufactured by the milling method was significantly higher than the RMS value (52±9 µm) of the model produced by the 3D printing method. The accuracy of the 3D printing method is superior to that of the milling method, but at present, both methods are limited in their application as a work model for prosthesis manufacture.
NASA Astrophysics Data System (ADS)
Alkali, A. U.; Ginta, T. L.; Abdulrani, A. M.; Elsiti, N. M.
2018-04-01
Various heat sources have been investigated by numerous researchers to reveal machinability benefits of thermally assisted machining (TAM) process. Fewer engineering materials have been tested. In the same vein, those researches continue to demonstrate effective performance of TAM in terms of bulk material removal rate, improved surface finish, prolong tool life and reduction of cutting forces among others. Experimental investigation on the strain-hardenability and flow stress of material removed with respect to increase in temperature in TAM has not been given attention in previous studies. This study investigated the pattern of chip morphology and segmentation giving close attention to influence of external heat source responsible for strain – hardenability of the material removed during TAM and dry machining at room temperature. Full immersion down cut milling was used throughout the machining conditions. Machining was conducted on AISI 316L using uncoated tungsten carbide end mill insert at varying cutting speeds (V) of 50, 79, and 100 m/min, and feed rates (f) of 0.15, 0.25, and 0.4 mm/tooth while the depth of cut was maintained at 0.2mm throughout the machining trials. The analyses of chip formation, segmentations and stain hardenability were carried out by using LMU light microscope, field emission microscopy and micro indentation. The study observed that build up edge is formed when a stagnation zone develops in front of tool tip which give rise to poor thermal gradient for conduction heat to be transferred within the bulk material during dry machining. This promotes varying strain – hardening of the material removed with evident high chips hardness and thickness, whereas TAM circumvents such impairment by softening the shear zone through local preheat.
DISPOSAL OF AN INTEGRATED PULP-PAPER MILL EFFLUENT BY IRRIGATION
In 1973, Simpson Paper Company initiated a research program to explore the use of the fully-treated secondary effluent from its Shasta Mill for beneficial crop irrigation. This report describes the operation of laboratory soil columns and field test plots, plus hydrological studi...
NASA Astrophysics Data System (ADS)
Sugeng, Bambang; Bandriyana, B.; Sugeng, Bambang; Salam, Rohmad; Sumariyo; Sujatno, Agus; Dimyati, Arbi
2018-03-01
Investigation on the relationship between the process conditions of milling time and the microstructure on the synthesis of the zirconia-ODS steel alloy has been performed. The elemental composition of the alloy was determined on 20 wt% Cr and zirconia dispersoid of 0.50 wt%. The synthesis was carried out by powder metallurgy method with milling time of 3, 5 and 7 hours, static compression of 20 Ton and sintering process for 4 minutes using the APS (Arc Plasma Sintering) equipment. SEM-EDX and XRD test was carried out to characterize the phase and morphology of the alloy and the effect to the mechanical properties was evaluated by the Vickers Hardness testing. The synthesis produced sample of ODS steel with good dense and very little porous with the Fe-Cr phase that clearly observed in the XRD peak pattern. In addition milling time increased the homogeneously of Fe-Cr phase formulation, enhanced the grain refinement of the structure and increase the hardness of the alloy.
Color Memory: A Yang-Mills Analog of Gravitational Wave Memory.
Pate, Monica; Raclariu, Ana-Maria; Strominger, Andrew
2017-12-29
A transient color flux across null infinity in classical Yang-Mills theory is considered. It is shown that a pair of test "quarks" initially in a color singlet generically acquire net color as a result of the flux. A nonlinear formula is derived for the relative color rotation of the quarks. For a weak color flux, the formula linearizes to the Fourier transform of the soft gluon theorem. This color memory effect is the Yang-Mills analog of the gravitational memory effect.
Color Memory: A Yang-Mills Analog of Gravitational Wave Memory
NASA Astrophysics Data System (ADS)
Pate, Monica; Raclariu, Ana-Maria; Strominger, Andrew
2017-12-01
A transient color flux across null infinity in classical Yang-Mills theory is considered. It is shown that a pair of test "quarks" initially in a color singlet generically acquire net color as a result of the flux. A nonlinear formula is derived for the relative color rotation of the quarks. For a weak color flux, the formula linearizes to the Fourier transform of the soft gluon theorem. This color memory effect is the Yang-Mills analog of the gravitational memory effect.
NASA Astrophysics Data System (ADS)
Matras, A.
2017-08-01
The paper discusses the impact of the feed screw heating on the machining accuracy. The test stand was built based on HASS Mini Mill 2 CNC milling machine and a Flir SC620 infrared camera. Measurements of workpiece were performed on Talysurf Intra 50 Taylor Hobson profilometer. The research proved that the intensive work of the milling machine lasted 60 minutes, causing thermal expansion of the feed screw what influence on the dimension error of the workpiece.
Dinesh Kumar, K. K.; Bhardwaj, Neerja; Yaddanapudi, Sandhya
2017-01-01
Background and Aims: It is not known whether trapezius squeeze test (TPZ) is a better clinical test than jaw thrust (JT) to assess laryngeal mask airway (LMA) insertion conditions in children under sevoflurane anesthesia. Material and Methods: After the Institutional Ethics Committee approval and written informed parental consent, 124 American Society of Anesthesiologists I and II children of 2–8 years of age undergoing minor surgical procedures were randomized into TPZ and JT groups. The children were induced with 8% sevoflurane in oxygen at a fresh gas flow of 4 L/min. TPZ or JT was performed after 1 min of start of sevoflurane and then every 20 s till the test was negative, when end-tidal (ET) sevoflurane concentration was noted. Classic LMA of requisite size was inserted by a blinded anesthetist and conditions at the insertion of LMA, insertion time, and the number of attempts of LMA insertion were recorded. Results: The mean LMA insertion time was significantly longer (P < 0.001) for TPZ (145 ± 28.7 sec) compared to JT group (111.8 ± 31.0 sec). ET sevoflurane concentration at the time of LMA insertion was comparable in the two groups. LMA insertion conditions were similar in the two groups. There was no difference between the two groups regarding total number of attempts of LMA insertion. Heart rate (HR) decreased in both groups after LMA insertion (P < 0.001) but TPZ group had significantly lower HR compared with the JT group up to 5 min after LMA insertion (P = 0.03). Conclusion: Both JT and TPZ are equivalent clinical indicators in predicting the optimal conditions of LMA insertion in spontaneously breathing children; however, it takes a longer time to achieve a negative TPZ squeeze test. PMID:28413275
Allergic contact dermatitis from a paper mill slimicide containing 2-bromo-4'-hydroxyacetophenone.
Jensen, Charlotte D; Andersen, Klaus E
2003-03-01
Slimicides are biocidal products used in paper mills to inhibit the proliferation of slime-forming microorganisms that would otherwise spoil the paper products. A laboratory technician working at a paper mill had recurring dermatitis related to contact with the slimicide Busan 1130. We report the first case of allergic contact dermatitis from the slimicide Busan 1130. Diagnostic patch testing was performed with solutions of Busan 1130 and its active ingredient, 2-bromo-4'-hydroxyacetophenone (BHAP). Twenty-five controls were also tested. The patient showed a ++ reaction to 0.1% Busan 1130 aqueous solution and 0.01% BHAP in ethanol. All controls were negative. The patient had recurrent allergic contact dermatitis from exposure to BHAP contained in the slimicide Busan 1130.
ERIC Educational Resources Information Center
Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.
The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…
Tavakolian, Samira; Doulabi, Mahbobeh Ahmadi; Baghban, Alireza Akbarzade; Mortazavi, Alireza; Ghorbani, Maryam
2015-01-01
Introduction: Copper IUD is a long term and reversible contraception which equals tubal ligation in terms of sterilization. One of the barriers to using this contraception method is the fear and the pain associated with its insertion. Eutectic mixture of local anesthetics (EMLA) 5% is a local anesthetic that contains 25 mg lidocaine and 25 mg of prilocaine per gram. Application of topical analgesic cream to the cervix for laser surgery, hysteroscopy and hysterosalpingography is known Aims: this study aimed to determine the effect of EMLA on IUD insertion pain. Methods: This triple blind clinical trial was conducted on 92 women in a clinic in Hamedan in 2012. After applying the cream on the cervix, pain in three steps, after using Tenaculum, after inserting hystrometr and after inserting IUD and removing IUD insertion tube were assessed with visual analog scale and were compared in EMLA group and placebo group Statistical analysis used to determine and compare the pain of independent t tests, Mann-Whitney U test and repeated measures analysis of variance and chi-square tests to determine the homogeneity of variables and Fisher’s exact test was used Results: Insertion hystrometr was determined as the most painful IUD insertion. The mean pain at step 2 (inserting hystrometr) was (3/11±2/53) in EMLA group, (5/23±2/31) in placebo group. EMLA cream significantly reduced the pain after using tenaculum (P<0/001), pain inserting Hystrometr (P< 0/001) and pain at IUD insertion and removing insertion tube (P< 0/001) Conclusions: Topical Application of EMLA 5% cream as a topical anesthetic on the cervix before insertion IUD reduced the pain during this procedure. PMID:25946948
Passivity of the bars manufactured using current technologies: laser-sintering, casting, and milling
NASA Astrophysics Data System (ADS)
Popescu, Diana; Popescu, Sabin; Pop, Daniel; Jivanescu, Anca; Todea, Carmen
2014-01-01
Implant overdentures are often selected as therapeutic options for the treatment of edentulous mandibles. "Passive-fit" between the mesostructures and the implants plays an important role in the longevity of the implant-prosthetic assembly in the oral cavity. "Mis-fit" can cause mechanical or biological complications. The purpose of this test was to investigate the passive adaptation of the bars manufactured through different technologies, and in this respect two bars (short and long) were fabricated by each process: laser-sintering, milling, casting. The tensions induced by tightening the connection screw between the bars and the underlying implants were recorded using strain gauges and used as measuring and comparing tool in testing the bars' "passivity". The results of the test showed that the milled bars had the best "passive-fit", followed by laser-sintered bars, while cast bars had the lowest adaptation level.
Shiba, N; Kitaoka, H B; Cahalan, T D; Chao, E Y
1995-01-01
The efficacy of 3 shock-absorbing materials was compared by determining impact characteristics with a drop test method and also by testing the effect of each material when used as a shoe insert in 16 asymptomatic subjects. Peak vertical ground reaction force (F1, F2, F3) and temporal force factors (T1, T2, T3) were obtained with a force plate at a high-frequency sampling rate. Impact force, impact time, impact slope, and impact energy were determined. A standard weight was dropped from 3 heights on each material covering the force plate while reduction of peak force was compared. Impact force was attenuated most effectively by Insert 3 (polymeric foam rubber) and averaged 11% less than that in shoes without inserts. Impact time was increased for all 3 inserts. Impact slope and impact energy were reduced significantly in Insert 3. There was a significant difference in peak vertical force F1 for all 3 inserts, in vertical force F2 for Insert 2 (viscoelastic polymeric material), and in vertical force F3 for Insert 2. Drop-test studies showed that at all ball heights, the highest mean peak force was observed consistently in Insert 2.
ERIC Educational Resources Information Center
Reynolds, Ralph E.; And Others
1979-01-01
College students read a text either with or without inserted questions. Question groups performed better, relative to controls, on post-test items that repeated inserted questions, and on new post-test items from the same categories as the inserted questions. A selective attention interpretation of the effect of inserted questions was made.…
Fit of interim crowns fabricated using photopolymer-jetting 3D printing.
Mai, Hang-Nga; Lee, Kyu-Bok; Lee, Du-Hyeong
2017-08-01
The fit of interim crowns fabricated using 3-dimensional (3D) printing is unknown. The purpose of this in vitro study was to evaluate the fit of interim crowns fabricated using photopolymer-jetting 3D printing and to compare it with that of milling and compression molding methods. Twelve study models were fabricated by making an impression of a metal master model of the mandibular first molar. On each study model, interim crowns (N=36) were fabricated using compression molding (molding group, n=12), milling (milling group, n=12), and 3D polymer-jetting methods. The crowns were prepared as follows: molding group, overimpression technique; milling group, a 5-axis dental milling machine; and polymer-jetting group using a 3D printer. The fit of interim crowns was evaluated in the proximal, marginal, internal axial, and internal occlusal regions by using the image-superimposition and silicone-replica techniques. The Mann-Whitney U test and Kruskal-Wallis tests were used to compare the results among groups (α=.05). Compared with the molding group, the milling and polymer-jetting groups showed more accurate results in the proximal and marginal regions (P<.001). In the axial regions, even though the mean discrepancy was smallest in the molding group, the data showed large deviations. In the occlusal region, the polymer-jetting group was the most accurate, and compared with the other groups, the milling group showed larger internal discrepancies (P<.001). Polymer-jet 3D printing significantly enhanced the fit of interim crowns, particularly in the occlusal region. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Yazdi, Ashkan K; Smyth, Hugh D C
2017-03-01
To optimize air-jet milling conditions of ibuprofen (IBU) using design of experiment (DoE) method, and to test the generalizability of the optimized conditions for the processing of another non-steroidal anti-inflammatory drug (NSAID). Bulk IBU was micronized using an Aljet mill according to a circumscribed central composite (CCC) design with grinding and pushing nozzle pressures (GrindP, PushP) varying from 20 to 110 psi. Output variables included yield and particle diameters at the 50th and 90th percentile (D 50 , D 90 ). Following data analysis, the optimized conditions were identified and tested to produce IBU particles with a minimum size and an acceptable yield. Finally, indomethacin (IND) was milled using the optimized conditions as well as the control. CCC design included eight successful runs for milling IBU from the ten total runs due to powder "blowback" from the feed hopper. DoE analysis allowed the optimization of the GrindP and PushP at 75 and 65 psi. In subsequent validation experiments using the optimized conditions, the experimental D 50 and D 90 values (1.9 and 3.6 μm) corresponded closely with the DoE modeling predicted values. Additionally, the optimized conditions were superior over the control conditions for the micronization of IND where smaller D 50 and D 90 values (1.2 and 2.7 μm vs. 1.8 and 4.4 μm) were produced. The optimization of a single-step air-jet milling of IBU using the DoE approach elucidated the optimal milling conditions, which were used to micronize IND using the optimized milling conditions.
Biofuel manufacturing from woody biomass: effects of sieve size used in biomass size reduction.
Zhang, Meng; Song, Xiaoxu; Deines, T W; Pei, Z J; Wang, Donghai
2012-01-01
Size reduction is the first step for manufacturing biofuels from woody biomass. It is usually performed using milling machines and the particle size is controlled by the size of the sieve installed on a milling machine. There are reported studies about the effects of sieve size on energy consumption in milling of woody biomass. These studies show that energy consumption increased dramatically as sieve size became smaller. However, in these studies, the sugar yield (proportional to biofuel yield) in hydrolysis of the milled woody biomass was not measured. The lack of comprehensive studies about the effects of sieve size on energy consumption in biomass milling and sugar yield in hydrolysis process makes it difficult to decide which sieve size should be selected in order to minimize the energy consumption in size reduction and maximize the sugar yield in hydrolysis. The purpose of this paper is to fill this gap in the literature. In this paper, knife milling of poplar wood was conducted using sieves of three sizes (1, 2, and 4 mm). Results show that, as sieve size increased, energy consumption in knife milling decreased and sugar yield in hydrolysis increased in the tested range of particle sizes.
NASA Astrophysics Data System (ADS)
Varol, T.; Canakci, A.
2013-06-01
In the present work, the effect of milling parameters on the morphology and microstructure of nanostructure Al2024-B4C composite powders obtained by mechanical alloying (MA) was studied. The effects of milling time and B4C content on the morphology, microstructure and particle size of nanostructure Al2024-B4C composite powders have been investigated. Different amounts of B4C particles (0, 5, 10 and 20 wt.%) were mixed with Al2024 powders and milled in a planetary ball mill for 30, 60, 120, 300, 420 and 600 min. Al 2024-B4C composite powders were characterized using a scanning electron microscope (SEM), laser particle-size analyzer, X-ray diffraction analysis (XRD) and the Vickers microhardness test. The results showed that the nanostructure Al2024-B4C composite powders were produced when they were milled for 600 min. The size of composite powder in the milled powder mixture was affected by the milling time and content of B4C particles. Moreover, it was observed that when MA reached a steady state, the properties of composite powders were stabilized.
Waltz Mill testing of 345-kV PPP cable
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burghardt, R.R.
1991-09-01
A 345-kV PPP-insulated cable was subjected to a two-year accelerated life test program at the EPRI Waltz Mill Cable Test Facility. Testing started in November 1985 and was successfully completed in September 1988. The program included conductor temperatures ranging from 85{degrees}C to 105{degrees}C and line-to-line voltages from 362 kV to 474 kV. Cyclic testing was performed during 17 of the 24 months. Dissipation factor measurements were made throughout the program. The measurements indicated no deterioration of the cable or splices as a consequence of the high temperatures and voltages applied to them in this test program. 2 refs., 24 figs.
Waltz Mill testing of 765-kV paper-polypropylene-paper (PPP) cable. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burghardt, R.R.
1992-06-01
A 765-kV PPP-insulated cable was subjected to a 27-month accelerated life test program at the EPRI Waltz Mill Cable Test Facility. Testing started in August 1981 and was successfully completed in January 1985. The program included conductor temperatures ranging from 85{degree}C to 105{degree}C and line-to-line voltages from 800 kV to 1050 kV. Cyclic testing was performed during 20 of the 27 months. Dissipation factor measurements were made throughout the program. The measurements indicated no deterioration of the cable or splices as a consequence of the high temperatures and voltages applied to them in this test program.
Waltz Mill testing of 765-kV paper-polypropylene-paper (PPP) cable
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burghardt, R.R.
1992-06-01
A 765-kV PPP-insulated cable was subjected to a 27-month accelerated life test program at the EPRI Waltz Mill Cable Test Facility. Testing started in August 1981 and was successfully completed in January 1985. The program included conductor temperatures ranging from 85{degree}C to 105{degree}C and line-to-line voltages from 800 kV to 1050 kV. Cyclic testing was performed during 20 of the 27 months. Dissipation factor measurements were made throughout the program. The measurements indicated no deterioration of the cable or splices as a consequence of the high temperatures and voltages applied to them in this test program.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rojas-Chavez, H., E-mail: uu_gg_oo@yahoo.com.mx; Reyes-Carmona, F.; Jaramillo-Vigueras, D.
2011-10-15
Highlights: {yields} PbSe synthesized from PbO instead of Pb powder do not require an inert atmosphere. {yields} During high-energy milling oxygen has to be chemically reduced from the lead oxide. {yields} Solid-state and solid-gas chemical reactions promote both solid and gaseous products. -- Abstract: Both solid-solid and gas-solid reactions have been traced during high-energy milling of Se and PbO powders under vial (P, T) conditions in order to synthesize the PbSe phase. Chemical and thermodynamic arguments are postulated to discern the high-energy milling mechanism to transform PbO-Se micropowders onto PbSe-nanocrystals. A set of reactions were evaluated at around room temperature.more » Therefore an experimental campaign was designed to test the nature of reactions in the PbO-Se system during high-energy milling.« less
Prevalence of Chronic Respiratory Disease in a Pulp Mill and a Paper Mill in the United States1
Ferris, B. G.; Burgess, W. A.; Worcester, J.
1967-01-01
A sample of 147 men drawn from the workers in a pulp mill was compared with one of 124 men from a paper mill. The former included those exposed to chlorine and to sulphur dioxide. No significant differences were found in respiratory symptoms or in simple tests of ventilatory function in the two samples, but men working in chlorine had a somewhat poorer respiratory function and more shortness of breath than those working in sulphur dioxide. The working population of both mills together had a lower prevalence of respiratory disease than that of the male population of Berlin, N.H., previously studied, suggesting that working populations may not be representative of the general population. Further, a low prevalence of disease in a working population exposed to pollutants may not indicate their `safety' in general populations. PMID:6017136
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-14
..., paper mill, saw mill, and oil refinery repairs; casting services for ``grey iron and brass,'' including... surface soil hot spots, sampling of surface water and sediment in the canals, stratigraphic profiling with..., monitor well installation, ground water sampling, and aquifer testing. Foundry operations resulted in...
76 FR 44535 - Testing of Bisphenol A
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-26
... Web site is an ``anonymous access'' system, which means EPA will not know your identity or contact... INFORMATION: I. General Information A. Does this action apply to me? You may be potentially affected by this.... Paper recyclers (NAICS codes 322110, 322121, 3222), e.g., pulp mills, paper (except newsprint) mills...
Analysis of a MIL-L-27502 lubricant from a gas-turbine engine test by size-exclusion chromatography
NASA Technical Reports Server (NTRS)
Jones, W. R., Jr.; Morales, W.
1983-01-01
Size exclusion chromatography was used to determine the chemical degradation of MIL-L-27502 oil samples from a gas turbine engine test run at a bulk oil temperature of 216 C. Results revealed a progressive loss of primary ester and additive depletion and the formation of higher molecular weight products with time. The high molecular weight products absorbed strongly in the ultraviolet indicating the presence of chromophoric groups.
Clark, Edward G; Paparello, James J; Wayne, Diane B; Edwards, Cedric; Hoar, Stephanie; McQuillan, Rory; Schachter, Michael E; Barsuk, Jeffrey H
2014-01-01
Simulation-based-mastery-learning (SBML) is an effective method to train nephrology fellows to competently insert temporary, non-tunneled hemodialysis catheters (NTHCs). Previous studies of SBML for NTHC-insertion have been conducted at a local level. Determine if SBML for NTHC-insertion can be effective when provided at a national continuing medical education (CME) meeting. Describe the correlation of demographic factors, prior experience with NTHC-insertion and procedural self-confidence with simulated performance of the procedure. Pre-test - post-test study. 2014 Canadian Society of Nephrology annual meeting. Nephrology fellows, internal medicine residents and medical students. Participants were surveyed regarding demographics, prior NTHC-insertion experience, procedural self-confidence and attitudes regarding the training they received. NTHC-insertion skills were assessed using a 28-item checklist. Participants underwent a pre-test of their NTHC-insertion skills at the internal jugular site using a realistic patient simulator and ultrasound machine. Participants then had a training session that included a didactic presentation and 2 hours of deliberate practice using the simulator. On the following day, trainees completed a post-test of their NTHC-insertion skills. All participants were required to meet or exceed a minimum passing score (MPS) previously set at 79%. Trainees who did not reach the MPS were required to perform more deliberate practice until the MPS was achieved. Twenty-two individuals participated in SBML training. None met or exceeded the MPS at baseline with a median checklist score of 20 (IQR, 7.25 to 21). Seventeen of 22 participants (77%) completed post-testing and improved their scores to a median of 27 (IQR, 26 to 28; p < 0.001). All met or exceeded the MPS on their first attempt. There were no significant correlations between demographics, prior experience or procedural self-confidence with pre-test performance. Small sample-size and self-selection of participants. Costs could limit the long-term feasibility of providing this type of training at a CME conference. Despite most participants reporting having previously inserted NTHCs in clinical practice, none met the MPS at baseline; this suggests their prior training may have been inadequate.
Cascetta, Furio; Palombo, Adolfo; Scalabrini, Gianfranco
2003-04-01
In this paper the metrological behavior of two different insertion flowmeters (magnetic and turbine types) in large water pipes is described. A master-slave calibration was carried out in order to estimate the overall uncertainty of the tested meters. The experimental results show that (i) the magnetic insertion tested flowmeter performs the claimed accuracy (+/- 2%) within all the flow range (20:1); (ii) the insertion turbine tested meter, instead, reaches the claimed accuracy just in the upper zone of the flow range.
Development of MoSi2 coating with Al doping by using high energy milling method
NASA Astrophysics Data System (ADS)
Simanjuntak, C. M. S.; Hastuty, S.; Izzuddin, H.; Sundawa, R.; Sudiro, T.; Sukarto, A.; Thosin, K. A. Z.
2018-03-01
MoSi2 is well known as a material for high temperature application because it has high oxidation and corrosion resistance. The aim of this research is to develop MoSi2 coating with Al doping on Stainless Steel 316 (SS316) substrate using High-Energy Milling method. Aluminium is added to the coating as a dopant to increase formation of MoSi2 coating layer on the substrate. The variations used here based on the concentrations of doping Al (at.%) and duration of milling. Results show that the MoSi2 coatings with variations of 30 and 50 at.% of Al doping and 3 and 6 hours of milling times were successfully coated on the surface of SS 316 using the high-energy milling method. The most optimum coating result after oxidation test at 1100 °C for 100 hours is shown by MoSi2-30%Al with 3 hours of milling times. From the oxidation results, the Al doping into MoSi2 coating was able to increase the oxidation resistance of the SS 316 substrate.
Effect of insertion torque on bone screw pullout strength.
Lawson, K J; Brems, J
2001-05-01
The effect of insertion torque on the holding strength of 4.5-mm ASIF/AO cortical bone screws was studied in vitro. Screw holding strength was determined using an Instron materials testing machine (Bristol, United Kingdom) on 55 lamb femora and 30 human tibiocortical bone sections. Holding strength was defined as tensile stress at pullout with rapid loading to construct failure. Different insertion torques were tested, normalizing to the thickness of cortical bone specimen engaged. These represented low, intermediate, high, and thread-damaging insertion torque. All screws inserted with thread-damaging torque and single cortex engaging screws inserted to high torque tightening moments showed diminished holding strength. This loss of strength amounted to 40%-50% less than screws inserted with less torque.
NASA Technical Reports Server (NTRS)
Lunde, T.
1977-01-01
The accuracy of three accelerated flight-by-flight test methods for material selection, and fatigue substantiation of supersonic cruise aircraft structure was studied. The real time stresses and temperatures applied to the specimens were representative of the service conditions in the lower surface of a Mach 2.7 supersonic cruise aircraft wing root structure. Each real time flight lasted about 65 minutes, including about one hour at (500 F) in the cruise condition. Center notched coupon specimens from six titanium materials were tested: mill-annealed, duplex-annealed, and triplex-annealed Ti-8Al-1Mo-1V sheets; mill-annealed Ti-8Al-1Mo-1V extrusion; mill-annealed Ti-6Al-4V sheet; and solution-treated and aged Ti-6Al-4V extrusion. For duplex-annealed Ti-8Al-1Mo-1V sheet, specimens with single spotweld were also tested. The test results were studied in conjunction with other related data from the literature for: material selection, structural fabrication, fatigue resistance of supersonic cruise aircraft structure, and fatigue test acceleration procedures for supersonic cruise aircraft.
Wagner, Christina; Stock, Veronika; Merk, Susanne; Schmidlin, Patrick R; Roos, Malgorzata; Eichberger, Marlis; Stawarczyk, Bogna
2018-02-01
To investigate the retention loads of differently fabricated secondary telescopic polyetheretherketone (PEEK) crowns on cobalt-chromium primary crowns with different tapers. Cobalt-chromium primary crowns with 0°, 1°, and 2° tapers were constructed, milled, and sintered. Corresponding secondary crowns were fabricated by milling, pressing from pellets, and pressing from granules. For these nine test groups, the pull-off tests of each crown combination were performed 20 times, and the retention loads were measured (Zwick 1445, 50 mm/min). Data were analyzed using linear regression, covariance analysis, mixed models, Kruskal-Wallis, and Mann-Whitney U-test, together with the Benferroni-Holm correction. The mixed models covariance analysis reinforced stable retention load values (p = 0.162) for each single test sequence. There was no interaction between the groups and the separation cycles (p = 0.179). Milled secondary crowns with 0° showed the lowest mean retention load values compared to all tested groups (p = 0.003) followed by those pressed form pellets with 1°. Regarding the different tapers, no effect of manufacturing method on the results was observed within 1° and 2° groups (p = 0.540; p = 0.052); however, among the 0° groups, the milled ones showed significantly the lowest retention load values (p = 0.002). Among the manufacturing methods, both pressed groups showed no impact of taper on the retention load values (p > 0.324 and p > 0.123, respectively), whereas among the milled secondary crowns, the 0° taper showed significantly lower retention load values than the 1° and 2° taper (p < 0.002). Based on these results, telescopic crowns made of PEEK seem to show stable retention load values for each test sequence; however, data with thermo-mechanical aging are still required. In addition, further developments in CAD/CAM manufacturing of PEEK materials for telescopic crowns are warranted, especially for 0°. © 2016 by the American College of Prosthodontists.
The data obtained from the results of oscillographic investigations of the use of saline inorganic lubricants in the pilger mill rolling of steel...for experimental testing as lubricants in pilger mill pipe rolling. It is shown that with the use of the above developed compositions as high
1982-02-28
BRE O STNDADS 193- rC low& L --. -: !’- • ,- r;4; [.9 ’- DNA-TR-81-81 VALIDATION OF THE CONTRAST ATTENUATION TECHNIQUE ( CAT ) FOR DEDUCING DUST...TITLE (and Sublitle) S. TYPE OF REPORT & PERIOD COVERED VALIDATION OF THE CONTRAST ATTENUATION TECHNIQUE Technical Report ( CAT ) FOR DEDUCING DUST...SCATTERING AND EXTINCTION CONSIDERATIONS- -------- 77 C DATA ON FILMS*USED FOR THE MILL RACE CAT TEST -- ------- 85 2
Characterization of the NEXT Hollow Cathode Inserts After Long-Duration Testing
NASA Technical Reports Server (NTRS)
Mackey, J.; Shastry, R.; Soulas, G.
2017-01-01
Hollow dispenser cathode inserts are a critical element of electric propulsion systems, and should therefore be well understood during long term operation to ensure reliable system performance. This work destructively investigated cathode inserts from the NEXT long-duration test which demonstrated 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The characterization methods used include scanning electron microscopy with energy dispersive spectroscopy and X-ray diffraction. Microscopy analysis has been performed on fractured surfaces, emission surfaces, and metallographically polished cross-sections of post-test inserts and unused inserts. Impregnate distribution, etch region thickness, impregnate chemical content, emission surface topography, and emission surface phase identification are the primary factors investigated.
Preliminary Testing of a Compact, Bone-Attached Robot for Otologic Surgery
Dillon, Neal P.; Balachandran, Ramya; dit Falisse, Antoine Motte; Wanna, George B.; Labadie, Robert F.; Withrow, Thomas J.; Fitzpatrick, J. Michael; Webster, Robert J.
2014-01-01
Otologic surgery often involves a mastoidectomy procedure, in which part of the temporal bone is milled away in order to visualize critical structures embedded in the bone and safely access the middle and inner ear. We propose to automate this portion of the surgery using a compact, bone-attached milling robot. A high level of accuracy is required to avoid damage to vital anatomy along the surgical path, most notably the facial nerve, making this procedure well-suited for robotic intervention. In this study, several of the design considerations are discussed and a robot design and prototype are presented. The prototype is a 4 degrees-of-freedom robot similar to a four-axis milling machine that mounts to the patient’s skull. A positioning frame, containing fiducial markers and attachment points for the robot, is rigidly attached to the skull of the patient, and a CT scan is acquired. The target bone volume is manually segmented in the CT by the surgeon and automatically converted to a milling path and robot trajectory. The robot is then attached to the positioning frame and is used to drill the desired volume. The accuracy of the entire system (image processing, planning, robot) was evaluated at several critical locations within or near the target bone volume with a mean free space accuracy result of 0.50 mm or less at all points. A milling test in a phantom material was then performed to evaluate the surgical workflow. The resulting milled volume did not violate any critical structures. PMID:25477726
Mechanical properties and superficial characterization of a milled CAD-CAM glass fiber post.
Ruschel, George Hebert; Gomes, Érica Alves; Silva-Sousa, Yara Terezinha; Pinelli, Rafaela Giedra Pirondi; Sousa-Neto, Manoel Damião; Pereira, Gabriel Kalil Rocha; Spazzin, Aloísio Oro
2018-06-01
Computer-aided design and computer-aided manufacturing (CAD-CAM) technology may be used to produce custom intraradicular posts, but studies are lacking. The purpose of this in vitro study was to evaluate the flexural properties (strength and modulus), failure mode, superficial morphology, and roughness of two CAD-CAM glass fiber posts (milled at different angulations) compared with a commercially available prefabricated glass fiber post. Three groups were tested (n = 10): PF (control group)- prefabricated glass fiber post; C-Cd-diagonally milled post; and C-Cv-vertically milled post. A 3-dimensional virtual image was obtained from a prefabricated post, which guided the posterior milling of posts from a glass fiber disk (Trilor Blanks; Bioloren). Surface roughness and morphology were evaluated using confocal laser microscopy. Flexural strength and modulus were evaluated with the 3-point bend test. Data were submitted to one-way analysis of variance followed by the Student-Newman-Keuls post hoc test (α = 0.05). The fractured surfaces were evaluated with scanning electron microscopy. The superficial roughness was highest for PF and similar for the experimental groups. Morphological analysis shows different sizes and directions of the glass fibers along the post. The flexural strength was highest for PF (900.1 ± 30.4 > C-Cd - 357.2 ± 30.7 > C-Cv 101.8 ± 4.3 MPa) as was the flexural modulus (PF 19.3 ± 2.0 GPa > C-Cv 10.1 ± 1.9 GPa > C-Cd 7.8 ± 1.3 GPa). A CAD-CAM milled post seems a promising development, but processing requires optimizing, as the prefabricated post still shows better mechanical properties and superficial characteristics. Copyright © 2018 Elsevier Ltd. All rights reserved.
de França, Danilo Gonzaga; Morais, Maria Helena; das Neves, Flávio D; Carreiro, Adriana Fonte; Barbosa, Gustavo As
The aim of this study was to evaluate the effectiveness of fabrication methods (computer-aided design/computer-aided manufacture [CAD/CAM], copy-milling, and conventional casting) in the fit accuracy of three-unit, screw-retained fixed dental prostheses. Sixteen three-unit implant-supported screw-retained frameworks were fabricated to fit an in vitro model. Eight frameworks were fabricated using the CAD/CAM system, four in zirconia and four in cobalt-chromium. Four zirconia frameworks were fabricated using the copy-milled system, and four were cast in cobalt-chromium using conventional casting with premachined abutments. The vertical and horizontal misfit at the implant-framework interface was measured using scanning electron microscopy at ×250. The results for vertical misfit were analyzed using Kruskal-Wallis and Mann-Whitney tests. The horizontal misfits were categorized as underextended, equally extended, or overextended. Statistical analysis established differences between groups according to the chi-square test (α = .05). The mean vertical misfit was 5.9 ± 3.6 μm for CAD/CAM-fabricated zirconia, 1.2 ± 2.2 μm for CAD/CAM-fabricated cobalt-chromium frameworks, 7.6 ± 9.2 μm for copy-milling-fabricated zirconia frameworks, and 11.8 (9.8) μm for conventionally fabricated frameworks. The Mann-Whitney test revealed significant differences between all but the zirconia-fabricated frameworks. A significant association was observed between the horizontal misfits and the fabrication method. The percentage of horizontal misfits that were underextended and overextended was higher in milled zirconia (83.3%), CAD/CAM cobaltchromium (66.7%), cast cobalt-chromium (58.3%), and CAD/CAM zirconia (33.3%) frameworks. CAD/CAM-fabricated frameworks exhibit better vertical misfit and low variability compared with copy-milled and conventionally fabricated frameworks. The percentage of interfaces equally extended was higher when CAD/CAM and zirconia were used.
Opp, Daniel; Nelms, Benjamin E.; Zhang, Geoffrey; Stevens, Craig
2013-01-01
3DVH software (Sun Nuclear Corp., Melbourne, FL) is capable of generating a volumetric patient VMAT dose by applying a volumetric perturbation algorithm based on comparing measurement‐guided dose reconstruction and TPS‐calculated dose to a cylindrical phantom. The primary purpose of this paper is to validate this dose reconstruction on an anthropomorphic heterogeneous thoracic phantom by direct comparison to independent measurements. The dosimetric insert to the phantom is novel, and thus the secondary goal is to demonstrate how it can be used for the hidden target end‐to‐end testing of VMAT treatments in lung. A dosimetric insert contains a 4 cm diameter unit‐density spherical target located inside the right lung (0.21g/cm3 density). It has 26 slots arranged in two orthogonal directions, milled to hold optically stimulated luminescent dosimeters (OSLDs). Dose profiles in three cardinal orthogonal directions were obtained for five VMAT plans with varying degrees of modulation. After appropriate OSLD corrections were applied, 3DVH measurement‐guided VMAT dose reconstruction agreed 100% with the measurements in the unit density target sphere at 3%/3 mm level (composite analysis) for all profile points for the four less‐modulated VMAT plans, and for 96% of the points in the highly modulated C‐shape plan (from TG‐119). For this latter plan, while 3DVH shows acceptable agreement with independent measurements in the unit density target, in the lung disagreement with experiment is relatively high for both the TPS calculation and 3DVH reconstruction. For the four plans excluding the C‐shape, 3%/3mm overall composite analysis passing rates for 3DVH against independent measurement ranged from 93% to 100%. The C‐shape plan was deliberately chosen as a stress test of the algorithm. The dosimetric spatial alignment hidden target test demonstrated the average distance to agreement between the measured and TPS profiles in the steep dose gradient area at the edge of the 2 cm target to be 1.0±0.7,0.3±0.3, and 0.3±0.3mm for the IEC X, Y, and Z directions, respectively. PACS number: 87.55Qr PMID:23835381
NASA Astrophysics Data System (ADS)
Ibrahim, Nurul Farhana; Mohamad, Hasmaliza; Noor, Siti Noor Fazliah Mohd
2016-12-01
The present work aims to study the effects of using different milling media on bioactive glass produced through melt-derived method for biomaterial application. The bioactive glass powder based on SiO2-CaO-Na2O-P2O5 system was fabricated using two different types of milling media which are tungsten carbide (WC) and zirconia (ZrO2) balls. However, in this work, no P2O5 was added in the new composition. XRF analysis indicated that tungsten trioxide (WO3) was observed in glass powder milled using WC balls whereas ZrO2 was observed in glass powder milled using ZrO2 balls. Amorphous structure was detected with no crystalline peak observed through XRD analysis for both glass powders. FTIR analysis confirmed the formation of silica network with the existence of functional groups Si-O-Si (bend), Si-O-Si (tetrahedral) and Si-O-Si (stretch) for both glass powders. The results revealed that there was no significant effect of milling media on amorphous silica network glass structure which shows that WC and zirconia can be used as milling media for bioactive glass fabrication without any contamination. Therefore, the fabricated BG can be tested safely for bioactivity assessment in biological fluids environment.
Hofmann, Felix; Harder, Ross J.; Liu, Wenjun; ...
2018-05-11
Here, this study presents a detailed examination of the lattice distortions introduced by glancing incidence Focussed Ion Beam (FIB) milling. Using non-destructive multi-reflection Bragg coherent X-ray diffraction we probe damage formation in an initially pristine gold micro-crystal following several stages of FIB milling. These experiments allow access to the full lattice strain tensor in the micro-crystal with ~25 nm 3D spatial resolution, enabling a nano-scale analysis of residual lattice strains and defects formed. Our results show that 30 keV glancing incidence milling produces fewer large defects than normal incidence milling at the same energy. However the resulting residual lattice strainsmore » have similar magnitude and extend up to ~50 nm into the sample. At the edges of the milled surface, where the ion-beam tails impact the sample at near-normal incidence, large dislocation loops with a range of Burgers vectors are formed. Further glancing incidence FIB polishing with 5 keV ion energy removes these dislocation loops and reduces the lattice strains caused by higher energy FIB milling. However, even at the lower ion energy, damage-induced lattice strains are present within a ~20 nm thick surface layer. These results highlight the need for careful consideration and management of FIB damage. They also show that low-energy FIB-milling is an effective tool for removing FIB-milling induced lattice strains. This is important for the preparation of micro-mechanical test specimens and strain microscopy samples.« less
Casing window milling with abrasive fluid jet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vestavik, O.M.; Fidtje, T.H.; Faure, A.M.
1995-12-31
Methods for through tubing re-entry drilling of multilateral wells has a large potential for increasing hydrocarbon production and total recovery. One of the bottle-necks of this technology is initiation of the side-track by milling a window in the casing downhole. A new approach to this problem has been investigated in a joint industry project. An experimental set-up has been built for milling a 4 inch window in a 7 inch steel casing at surface in the laboratory. A specially designed bit developed at RIF using abrasive jet cutting technology has been used for the window milling. The bit has anmore » abrasive jet beam which is always directed in the desired side-track direction, even if the bit is rotating uniformly. The bit performs the milling with a combined mechanical and hydraulic jet action. The method has been successfully demonstrated. The experiments has shown that the window milling can be performed with very low WOB and torque, and that only small side forces are required to perform the operation. Casing milling has been performed without a whipstock, a cement plug has been the only support for the tool. The tests indicate that milling operations can be performed more efficiently with less time and costs than what is required with conventional techniques. However, the method still needs some development of the downhole motor for coiled tubing applications. The method can be used both for milling and drilling giving the advantage of improved rate of penetration, improved bit life and increased horizontal reach. The method is planned to be demonstrated downhole in the near future.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hofmann, Felix; Harder, Ross J.; Liu, Wenjun
Here, this study presents a detailed examination of the lattice distortions introduced by glancing incidence Focussed Ion Beam (FIB) milling. Using non-destructive multi-reflection Bragg coherent X-ray diffraction we probe damage formation in an initially pristine gold micro-crystal following several stages of FIB milling. These experiments allow access to the full lattice strain tensor in the micro-crystal with ~25 nm 3D spatial resolution, enabling a nano-scale analysis of residual lattice strains and defects formed. Our results show that 30 keV glancing incidence milling produces fewer large defects than normal incidence milling at the same energy. However the resulting residual lattice strainsmore » have similar magnitude and extend up to ~50 nm into the sample. At the edges of the milled surface, where the ion-beam tails impact the sample at near-normal incidence, large dislocation loops with a range of Burgers vectors are formed. Further glancing incidence FIB polishing with 5 keV ion energy removes these dislocation loops and reduces the lattice strains caused by higher energy FIB milling. However, even at the lower ion energy, damage-induced lattice strains are present within a ~20 nm thick surface layer. These results highlight the need for careful consideration and management of FIB damage. They also show that low-energy FIB-milling is an effective tool for removing FIB-milling induced lattice strains. This is important for the preparation of micro-mechanical test specimens and strain microscopy samples.« less
Pickett, M W; Kosegi, J E; Thomas, K S; Waterstram-Rich, K M
1998-09-01
This investigation evaluated the effectiveness of disposable plastic inserts in radiopharmaceutical unit dose lead containers (pigs) in preventing the distribution of doses in blood-contaminated containers. Technologists commonly dispose of the syringes by placing them into the lead pigs, leaving the needles uncapped. This process raises the question of unsuspected blood contamination of these pigs. Consequently, the distribution of commercially prepared radiopharmaceutical doses in reusable lead pigs may result in radiopharmaceutical doses being distributed in containers that are contaminated with blood. Using a simple chemical wipe test designed to determine the presence or absence of blood contamination, 618 pigs from commercial radiopharmacies throughout the U.S. were tested for contamination. The inside of the pigs and inserts, if present, were wiped before and after dose administration. Of the pigs tested, 292 came from radiopharmacies that used a protective, disposable plastic insert inside the pig, and 326 came from radiopharmacies that did not use an insert. Of those pigs without the protective disposable inserts, 39.3% arrived in the nuclear medicine department in pigs contaminated with blood. Of those pigs with inserts, 1% arrived with blood-contaminated inserts. After dose administration, 46.3% of the pigs without inserts were contaminated with blood and 3% of the protective inserts were contaminated. The proper use of disposable plastic inserts reduces the possibility of distributing radiopharmaceutical unit doses in containers contaminated with blood.
Sharifi, Maryam; Ghassemi, Amirreza; Bayani, Shahin
2015-01-01
Success of orthodontic miniscrews in providing stable anchorage is dependent on their stability. The purpose of this study was to assess the effect of insertion method and postinsertion time interval on the removal torque of miniscrews as an indicator of their stability. Seventy-two miniscrews (Jeil Medical) were inserted into the femoral bones of three male German Shepherd dogs and assigned to nine groups of eight miniscrews. Three insertion methods, including hand-driven, motor-driven with 5.0-Ncm insertion torque, and motor-driven with 20.0-Ncm insertion torque, were tested. Three time intervals of 0, 2, and 6 weeks between miniscrew insertion and removal were tested as well. Removal torque values were measured in newton centimeters by a removal torque tester (IMADA). Data were analyzed by one-way analysis of variance (ANOVA) followed by the Bonferroni post hoc test at a .05 level of significance. A miniscrew survival rate of 93% was observed in this study. The highest mean value of removal torque among the three postinsertion intervals (2.4 ± 0.59 Ncm) was obtained immediately after miniscrew insertion with a statistically significant difference from the other two time intervals (P < .001). Insertion were observed in this regard (P = .46). The stability of miniscrews was not affected by the insertion method. However, of the postinsertion time intervals, the highest removal torque values were obtained immediately after insertion.
NASA Astrophysics Data System (ADS)
Chen, Yunsheng; Lu, Xinghua
2018-05-01
The mechanical parts of the fuselage surface of the UAV are easily fractured by the action of the centrifugal load. In order to improve the compressive strength of UAV and guide the milling and planing of mechanical parts, a numerical simulation method of UAV fuselage compression under centrifugal load based on discrete element analysis method is proposed. The three-dimensional discrete element method is used to establish the splitting tensile force analysis model of the UAV fuselage under centrifugal loading. The micro-contact connection parameters of the UAV fuselage are calculated, and the yield tensile model of the mechanical components is established. The dynamic and static mechanical model of the aircraft fuselage milling is analyzed by the axial amplitude vibration frequency combined method. The correlation parameters of the cutting depth on the tool wear are obtained. The centrifugal load stress spectrum of the surface of the UAV is calculated. The meshing and finite element simulation of the rotor blade of the unmanned aerial vehicle is carried out to optimize the milling process. The test results show that the accuracy of the anti - compression numerical test of the UAV is higher by adopting the method, and the anti - fatigue damage capability of the unmanned aerial vehicle body is improved through the milling and processing optimization, and the mechanical strength of the unmanned aerial vehicle can be effectively improved.
Kato, Taku; Ohara, Satoshi; Fukushima, Yasuhiro; Sugimoto, Akira; Masuda, Takayuki; Yasuhara, Takaomi; Yamagishi, Hiromi
2016-07-01
Advances in glucose/fructose-selective ethanol production have successfully enhanced raw sugar extraction from sugarcane juice by converting inhibitory substances (i.e., glucose/fructose) into ethanol, which is removed by subsequent operations in cane sugar mills. However, the commercial implementation of this breakthrough process in existing cane sugar mills requires a yeast strain that (i) can be used in food production processes, (ii) exhibits stable saccharometabolic selectivity, and (iii) can be easily separated from the saccharide solution. In this study, we developed a suitable saccharometabolism-selective and flocculent strain, Saccharomyces cerevisiae GYK-10. We obtained a suitable yeast strain for selective fermentation in cane sugar mills using a yeast mating system. First, we crossed a haploid strain defective in sucrose utilization with a flocculent haploid strain. Next, we performed tetrad dissection of the resultant hybrid diploid strain and selected GYK-10 from various segregants by investigating the sucrose assimilation and flocculation capacity phenotypes. Ten consecutive fermentation tests of the GYK-10 strain using a bench-scale fermentor confirmed its suitability for the implementation of practical selective fermentation in a commercial sugar mill. The strain exhibited complete saccharometabolic selectivity and sustained flocculation, where it maintained a high ethanol yield and conversion rate throughout the test. Copyright © 2016 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
Gleeble Testing of Tungsten Samples
2013-02-01
as a diffusion barrier to prevent the tungsten samples from fusing to the tungsten carbide inserts at elevated temperatures. After the anvils were...anvils with removable tungsten carbide inserts. The inserts were 19.05 mm (0.75 in) in diameter and 25.4 mm (1 in) long; they were purchased from...rhenium are shown in tables 6 and 7 and figure 7. The sample tested at 1300 °C, T4, partially embedded into the tungsten carbide (WC) inserts during
Development of USPS Laboratory and pilot-scale testing protocols
Carl Houtman; Nancy Ross Sutherland; David Bormett; Donald Donermeyer
2000-01-01
The ultimate goal of the US Postal Service (USPS) Environmentally Benign Stamp Program is to develop stamp adhesives that can be removed by unit operations found in recycling mills. The maintenance of final product quality specifications for a recycling mill while loading the feedstock with a significant quantity of adhesive is the criterion for success of this program...
Occupational hearing loss of market mill workers in the city of Accra, Ghana.
Kitcher, Emmanuel D; Ocansey, Grace; Abaidoo, Benjamin; Atule, Alidu
2014-01-01
Noise induced hearing loss (NIHL) is an irreversible sensorineural hearing loss associated with exposure to high levels of excessive noise. Prevention measures are not well established in developing countries. This comparative cross sectional study aims to determine the prevalence of hearing loss in both a group of high risk workers and a control group and to assess their knowledge of the effects of noise on hearing health. A total of 101 market mill workers and 103 controls employed within markets in the city of Accra, Ghana, were evaluated using a structured questionnaire and pure tone audiometry. The questionnaire assessed factors including self-reported hearing loss, tinnitus, knowledge on the effects of noise on hearing health and the use of hearing protective devices. Pure tone audiometric testing was conducted for both mill workers and controls. Noise levels at the work premises of the mill workers and controls were measured. Symptoms of hearing loss were reported by 24 (23.76%) and 8 (7.7%) mill workers and controls respectively. Fifty-five (54.5%) and fifty-four (52.37%) mill workers and controls exhibited knowledge of the effects of noise on hearing health. Five (5.0%) mill workers used hearing protective devices. There was significant sensorineural hearing loss and the presence of a 4 kHz audiometric notch among mill workers when compared with controls for the mean thresholds of 2 kHz, 3 kHz and 4 kHz (P = 0. 001). The prevalence of hearing loss in the better hearing ears of the mill workers and controls was 24.8% and 4.8% respectively (P < 0.5). The prevalence of hearing loss, which may be characteristic of NIHL in the better hearing ears of the mill workers and controls was 24.8% and 4.8% respectively. The majority of mill workers did not use hearing protection.
Hot fire test results of subscale tubular combustion chambers
NASA Technical Reports Server (NTRS)
Kazaroff, John M.; Jankovsky, Robert S.; Pavli, Albert J.
1992-01-01
Advanced, subscale, tubular combustion chambers were built and test fired with hydrogen-oxygen propellants to assess the increase in fatigue life that can be obtained with this type of construction. Two chambers were tested: one ran for 637 cycles without failing, compared to a predicted life of 200 cycles for a comparable smooth-wall milled-channel liner configuration. The other chamber failed at 256 cycles, compared to a predicted life of 118 cycles for a comparable smooth-wall milled-channel liner configuration. Posttest metallographic analysis determined that the strain-relieving design (structural compliance) of the tubular configuration was the cause of this increase in life.
Miller, Matthew; DuVall, Nicholas; Brewster, John; Wajdowicz, Michael N; Harris, Ashley; Roberts, Howard W
2018-02-18
To evaluate bicuspid axial wall height effect on the fracture mode of adhesively luted, all-ceramic CAD/CAM crowns with a 20° total occlusal convergence (TOC). Recently extracted premolars were randomly divided into 4 groups (n = 12) with all-ceramic crown preparations accomplished using a high-speed handpiece inserted into a milling device. Specimens were prepared containing occlusogingival axial wall heights of 3, 2, and 1 mm as well as a group containing a flat preparation surface with no axial wall height. All preparations contained a 20° TOC. Completed preparation surface area was determined, and preparation features confirmed using a digital measuring microscope. Scanned preparations (CEREC) were fitted with milled and crystallized lithium disilicate full coverage restorations and luted with a self-etching adhesive resin cement after hydrofluoric acid etching and silanation. All manufacturer recommendations were followed. Specimens were stored at 37°C/98% humidity for 24 hours. Specimens were tested to failure at a 45° angle to the long axis of the tooth root on a universal testing machine. Failure load was converted to MPa using the available bonding surface area with mean data analyzed using Kruskal-Wallis/Dunn's (p = 0.05) RESULTS: The 3 mm preparation height specimens were similar to the 2 mm specimens, and both demonstrated significantly stronger failure load than the 1 mm axial wall height and flat preparation specimens. The flat preparation and 1 mm axial wall height specimens all failed adhesively, while the 2 mm and 3 mm specimens failed largely due to tooth fracture. Further evidence is provided that CAD/CAM adhesive techniques may compensate for less than ideal preparation features. Under the conditions of this study, bicuspid preparations with a 20° TOC restored with adhesively luted, CAD/CAM e.max CAD crowns require at least 2 mm of axial wall height, but further planned fatigue studies are necessary before definitive recommendations can be made. © 2018 by the American College of Prosthodontists.
NASA Astrophysics Data System (ADS)
Dutton, Kenneth
Shape (or flatness) control for rolled steel strip is becoming increasingly important as customer requirements become more stringent. Automatic shape control is now more or less mandatory on all new four-high cold mills, but no comprehensive scheme yet exists on a Sendzimir mill. This is due to the complexity of the control system design on such a mill, where many more degrees of freedom for control exist than is the case with the four-high mills.The objective of the current work is to develop, from first principles, such a system; including automatic control of the As-U-Roll and first intermediate roll actuators in response to the measured strip shape. This thesis concerns itself primarily with the As-U-Roll control system. The material presented is extremely wide-ranging. Areas covered include the development of original static and dynamic mathematical models of the mill systems, and testing of the plant by data-logging to tune these models. A basic control system philosophy proposed by other workers is modified and developed to suit the practical system requirements and the data provided by the models. The control strategy is tested by comprehensive multivariable simulation studies. Finally, details are given of the practical problems faced when installing the system on the plant. These include problems of manual control inter-action bumpless transfer and integral desaturation.At the time of presentation of the thesis, system commissioning is still in progress and production results are therefore not yet available. Nevertheless, the simulation studies predict a successful outcome, although performance is expected to be limited until the first intermediate roll actuators are eventually included in the scheme also.
Xu, Wei; Li, Ming; Wen, Cuie; Lv, Shaomin; Liu, Chengcheng; Lu, Xin; Qu, Xuanhui
2018-03-30
A biocompatible Ti-28Nb-35.4Zr alloy used as bone implant was fabricated through the powder metallurgy process. The effects of mechanical milling and sintering temperatures on the microstructure and mechanical properties were investigated systematically, before in vitro biocompatibility of full dense Ti-28Nb-35.4Zr alloy was evaluated by cytotoxicity tests. The results show that the mechanical milling and sintering temperatures have significantly effects on the density and mechanical properties of the alloys. The relative density of the alloy fabricated by the atomized powders at 1500 °C is only 83 ± 1.8%, while the relative density of the alloy fabricated by the ball-milled powders can rapidly reach at 96.4 ± 1.3% at 1500 °C. When the temperature was increased to 1550 °C, the alloy fabricated by ball-milled powders achieve full density (relative density is 98.1 ± 1.2%). The PM-fabricated Ti-28Nb-35.4Zr alloy by ball-milled powders at 1550 °C can achieve a wide range of mechanical properties, with a compressive yield strength of 1058 ± 35.1 MPa, elastic modulus of 50.8 ± 3.9 GPa, and hardness of 65.8 ± 1.5 HRA. The in vitro cytotoxicity test suggests that the PM-fabricated Ti-28Nb-35.4Zr alloy by ball-milled powders at 1550 °C has no adverse effects on MC3T3-E1 cells with cytotoxicity ranking of 0 grade, which is nearly close to ELI Ti-6Al-4V or CP Ti. These properties and the net-shape manufacturability makes PM-fabricated Ti-28Nb-35.4Zr alloy a low-cost, highly-biocompatible, Ti-based biomedical alloy.
Three-dimensional patterning in polymer optical waveguides using focused ion beam milling
NASA Astrophysics Data System (ADS)
Kruse, Kevin; Burrell, Derek; Middlebrook, Christopher
2016-07-01
Waveguide (WG) photonic-bridge taper modules are designed for symmetric planar coupling between silicon WGs and single-mode fibers (SMFs) to minimize photonic chip and packaging footprint requirements with improving broadband functionality. Micromachined fabrication and evaluation of polymer WG tapers utilizing high-resolution focused ion beam (FIB) milling is performed and presented. Polymer etch rates utilizing the FIB and optimal methods for milling polymer tapers are identified for three-dimensional patterning. Polymer WG tapers with low sidewall roughness are manufactured utilizing FIB milling and optically tested for fabrication loss. FIB platforms utilize a focused beam of ions (Ga+) to etch submicron patterns into substrates. Fabricating low-loss polymer WG taper prototypes with the FIB before moving on to mass-production techniques provides theoretical understanding of the polymer taper and its feasibility for connectorization devices between silicon WGs and SMFs.
NASA Astrophysics Data System (ADS)
Zhang, Yanghuan; Shang, Hongwei; Hou, Zhonghui; Yuan, Zeming; Yang, Tai; Qi, Yan
2016-12-01
In this study, Mg was partially substituted by Ni with the intent of improving the hydrogen storage kinetics performance of NdMg12-type alloy. Mechanical milling technology was adopted to fabricate the nanocrystalline and amorphous NdMg11Ni + x wt pct Ni ( x = 100, 200) alloys. The effects of Ni content and milling duration on the microstructures and hydrogen storage kinetics of as-milled alloys have been systematically investigated. The structures were characterized by XRD and HRTEM. The electrochemical hydrogen storage properties were tested by an automatic galvanostatic system. Moreover, the gaseous hydrogen storage properties were investigated by Sievert apparatus and a differential scanning calorimeter connected with a H2 detector. Hydrogen desorption activation energy of alloy hydrides was estimated by using Arrhenius and Kissinger methods. The results reveal that the increase of Ni content dramatically ameliorates the gaseous and electrochemical hydrogen storage kinetics performance of the as-milled alloys. Furthermore, high rate discharge ability (HRD) reach the maximum value with the variation of milling time. The maximum HRDs of the NdMg11Ni + x wt pct Ni ( x = 100, 200) alloys are 80.24 and 85.17 pct. The improved gaseous hydrogen storage kinetics of alloys via increasing Ni content and milling time can be attributed to a decrease in the hydrogen desorption activation energy.
Nordin, Jamillah Amer; Prajitno, Djoko Hadi; Saidin, Syafiqah; Nur, Hadi; Hermawan, Hendra
2015-06-01
Hydroxyapatite (HAp) is an attractive bioceramics due to its similar composition to bone mineral and its ability to promote bone-implant interaction. However, its low strength has limited its application as load bearing implants. This paper presented a work focusing on the improvement of HAp mechanical property by synthesizing iron (Fe)-reinforced bovine HAp nanocomposite powders via mechanosynthesis method. The synthesis process was performed using high energy milling at varied milling time (3, 6, 9, and 12h). The samples were characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR), and scanning electron microscopy (SEM). Its mechanical properties were investigated by micro-Vicker's hardness and compression tests. Results showed that milling time directly influenced the characteristics of the nanocomposite powders. Amorphous BHAp was formed after 9 and 12h milling in the presence of HPO4(2-) ions. Continuous milling has improved the crystallinity of Fe without changing the HAp lattice structure. The nanocomposite powders were found in spherical shape, agglomerated and dense after longer milling time. The hardness and Young's modulus of the nanocomposites were also increased at 69% and 66%, respectively, as the milling time was prolonged from 3 to 12h. Therefore, the improvement of the mechanical properties of nanocomposite was attributed to high Fe crystallinity and homogenous, dense structure produced by mechanosynthesis. Copyright © 2015 Elsevier B.V. All rights reserved.
Dispersion of fine phosphor particles by newly developed beads mill
NASA Astrophysics Data System (ADS)
Joni, I. Made; Panatarani, C.; Maulana, Dwindra W.
2016-02-01
Fine phosphor Y2O3:Eu3+ particles has advanced properties compare to conventional particles applied for compact fluorescent lamp (CFL) as three band phosphor. However, suspension of fine particles easily agglomerated during preparation of spray coating of the CFL tube. Therefore, it is introduced newly developed beads mill system to disperse fine phosphor. The beads mill consist of glass beads, dispersing chamber (impellers), separator chamber, slurry pump and motors. The first important performance of beads mill is the performance of the designed on separating the beads with the suspended fine particles. We report the development of beads mill and its separation performance vary in flow rate and separator rotation speeds. The 27 kg of glass beads with 30 µm in size was poured into dispersing chamber and then water was pumped continuously through the slurry pump. The samples for the separation test was obtained every 1 hours vary in rotation speed and slurry flow rate. The results shows that the separation performance was 99.99 % obtained for the rotation speed of >1000 rpm and flow rate of 8 L/minute. The performances of the system was verified by dispersing fine phosphor Y2O3:Eu3+ particles with concentration 1 wt.%. From the observed size distribution of particles after beads mill, it is concluded that the current design of bead mill effectively dispersed fine phosphor Y2O3:Eu3+.
Benjamin O. Knapp; G. Geoff Wang; Joan L. Walker; Susan Cohen
2006-01-01
We tested the effects of eight site preparation treatments on early growth and survival of container-grown longleaf pine (Pinus palustris Mill.) seedlings. Treatments included an untreated check, six combinations of two initial vegetation control treatments (chopping or herbicide) with three planting site conditions (flat [no additional treatment],...
Powder metallurgy preparation of Mg-Ca alloy for biodegradable implant application
NASA Astrophysics Data System (ADS)
Annur, D.; Suhardi, A.; Amal, M. I.; Anwar, M. S.; Kartika, I.
2017-04-01
Magnesium and its alloys is a promising candidate for implant application especially due to its biodegradability. In this study, Mg-7Ca alloys (in weight %) were processed by powder metallurgy from pure magnesium powder and calcium granule. Milling process was done in a shaker mill using stainless steel balls in various milling time (3, 5, and 8 hours) followed by compaction and sintering process. Different sintering temperatures were used (450°C and 550°C) to examine the effect of sintering temperature on mechanical properties and corrosion resistance. Microstructure evaluation was characterized by X-ray diffraction, scanning electron microscope and energy dispersive X-ray spectroscopy. Mechanical properties and corrosion behavior were examined through hardness testing and electrochemical testing in Hank’s solution (simulation body fluid). In this report, a prolonged milling time reduced particle size and later affected mechanical properties of Mg alloy. Meanwhile, the phase analysis showed that α Mg, Mg2Ca, MgO phases were formed after the sintering process. Further, this study showed that Mg-Ca alloy with different powder metallurgy process would have different corrosion rate although there were no difference of Ca content in the alloy.
A proposed model membrane and test method for microneedle insertion studies.
Larrañeta, Eneko; Moore, Jessica; Vicente-Pérez, Eva M; González-Vázquez, Patricia; Lutton, Rebecca; Woolfson, A David; Donnelly, Ryan F
2014-09-10
A commercial polymeric film (Parafilm M(®), a blend of a hydrocarbon wax and a polyolefin) was evaluated as a model membrane for microneedle (MN) insertion studies. Polymeric MN arrays were inserted into Parafilm M(®) (PF) and also into excised neonatal porcine skin. Parafilm M(®) was folded before the insertions to closely approximate thickness of the excised skin. Insertion depths were evaluated using optical coherence tomography (OCT) using either a force applied by a Texture Analyser or by a group of human volunteers. The obtained insertion depths were, in general, slightly lower, especially for higher forces, for PF than for skin. However, this difference was not a large, being less than the 10% of the needle length. Therefore, all these data indicate that this model membrane could be a good alternative to biological tissue for MN insertion studies. As an alternative method to OCT, light microscopy was used to evaluate the insertion depths of MN in the model membrane. This provided a rapid, simple method to compare different MN formulations. The use of Parafilm M(®), in conjunction with a standardised force/time profile applied by a Texture Analyser, could provide the basis for a rapid MN quality control test suitable for in-process use. It could also be used as a comparative test of insertion efficiency between candidate MN formulations. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Li, Dongrui; Cheng, Zhigang; Chen, Gang; Liu, Fangyi; Wu, Wenbo; Yu, Jie; Gu, Ying; Liu, Fengyong; Ren, Chao; Liang, Ping
2018-04-03
To test the accuracy and efficacy of the multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors in phantom and animal models. To evaluate and compare the influences of intervention experience on robot-assisted and ultrasound-controlled ablation procedures. Accuracy tests on rigid body/phantom model with a respiratory movement simulation device and microwave ablation tests on porcine liver tumor/rabbit liver cancer were performed with the robot we designed or with the traditional ultrasound-guidance by physicians with or without intervention experience. In the accuracy tests performed by the physicians without intervention experience, the insertion accuracy and efficiency of robot-assisted group was higher than those of ultrasound-guided group with statistically significant differences. In the microwave ablation tests performed by the physicians without intervention experience, better complete ablation rate was achieved when applying the robot. In the microwave ablation tests performed by the physicians with intervention experience, there was no statistically significant difference of the insertion number and total ablation time between the robot-assisted group and the ultrasound-controlled group. The evaluation by the NASA-TLX suggested that the robot-assisted insertion and microwave ablation process performed by physicians with or without experience were more comfortable. The multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors could increase the insertion accuracy and ablation efficacy, and minimize the influence of the physicians' experience. The ablation procedure could be more comfortable with less stress with the application of the robot.
EFFECT OF PILOT HOLE TAPPING ON PULLOUT STRENGTH AND INSERTION TORQUE OF DUAL CORE PEDICLE SCREWS.
Rosa, Rodrigo César; Silva, Patrícia; Falcai, Maurício José; Shimano, Antônio Carlos; Defino, Helton Luiz Aparecido
2010-01-01
To evaluate the influence of pilot hole tapping on pullout resistance and insertion torque of pedicle screws with a conical core. Mechanical tests using a universal testing machine were performed on pedicle screws with a conical core that were inserted into pedicles in the fifth lumbar vertebra of calves. The insertion torque was measured using a torque meter with a capacity of 10 Nm, which was considered to be the highest torque value. The pilot holes were prepared using a probe of external diameter 3.8 mm and tapping of the same dimensions and thread characteristics as the screw. Decreased insertion torque and pullout resistance were observed in the group with prior tapping of the pilot hole. Pilot hole tapping reduced the insertion torque and pullout resistance of pedicle screws with a conical core that had been inserted into the pedicle of the fifth lumbar vertebra of calves.
Qi, Beier; Liu, Bo; Liu, Sha; Liu, Haihong; Dong, Ruijuan; Zhang, Ning; Gong, Shusheng
2011-05-01
To study the effect of cochlear electrode coverage and different insertion region on speech recognition, especially tone perception of cochlear implant users whose native language is Mandarin Chinese. Setting seven test conditions by fitting software. All conditions were created by switching on/off respective channels in order to simulate different insertion position. Then Mandarin CI users received 4 Speech tests, including Vowel Identification test, Consonant Identification test, Tone Identification test-male speaker, Mandarin HINT test (SRS) in quiet and noise. To all test conditions: the average score of vowel identification was significantly different, from 56% to 91% (Rank sum test, P < 0.05). The average score of consonant identification was significantly different, from 72% to 85% (ANOVNA, P < 0.05). The average score of Tone identification was not significantly different (ANOVNA, P > 0.05). However the more channels activated, the higher scores obtained, from 68% to 81%. This study shows that there is a correlation between insertion depth and speech recognition. Because all parts of the basement membrane can help CI users to improve their speech recognition ability, it is very important to enhance verbal communication ability and social interaction ability of CI users by increasing insertion depth and actively stimulating the top region of cochlear.
Effect of Bonding Agent Application Method on Titanium-Ceramic Bond Strength.
Curtis, Joseph G; Dossett, Jon; Prihoda, Thomas J; Teixeira, Erica C
2015-07-01
Although milled titanium may be used as a substructure in fixed and implant prosthodontics, the application of the veneering porcelain presents particular challenges compared to traditional alloys. To address these challenges, some Ti ceramic systems incorporate the application of a bonding agent prior to the opaque layer. Vita Titankeramik's bonding agent is available as a powder, paste, and spray-on formulation. We examined the effect of these three application methods on the bond strength. Four titanium bars were milled from each of 11 wafers cut from grade II Ti using the Kavo Everest milling unit and a custom-designed milling toolpath. An experienced technician prepared the 25 × 3 × 0.5 mm(3) metal bars and applied bonding agent using one of three application methods, and then applied opaque, dentin, and enamel porcelains according to manufacturer's instructions to a 8 × 3 × 1 mm(3) porcelain. A control group received no bonding agent prior to porcelain application. The four groups (n = 11) were blindly tested for differences in bond strength using a universal testing machine in a three-point bend test configuration, based on ISO 9693-1:2012. The average (SD) bond strengths for the control, powder, paste, and spray-on groups, respectively, were: 24.8 (2.6), 24.6 (2.6), 25.3 (4.0), and 24.1 (3.9) MPa. One-way ANOVA and Tukey's multiple comparison tests were performed between all groups. There were no statistically significant differences among groups (p = 0.951). Titanium-porcelain bond strength was not affected by the use of a bonding agent or its application method when tested by ISO 9693-1 standard. © 2014 by the American College of Prosthodontists.
Design and preliminary analysis of a vaginal inserter for speculum-free cervical cancer screening
Agudogo, Júlia; Krieger, Marlee S.; Miros, Robert; Proeschold-Bell, Rae Jean; Schmitt, John W.; Ramanujam, Nimmi
2017-01-01
Objective Cervical cancer screening usually requires use of a speculum to provide a clear view of the cervix. The speculum is one potential barrier to screening due to fear of pain, discomfort and embarrassment. The aim of this paper is to present and demonstrate the feasibility of a tampon-sized inserter and the POCkeT Colposcope, a miniature pen sized-colposcope, for comfortable, speculum-free and potentially self-colposcopy. Study design We explored different designs using 3D computer-aided design (CAD) software and performed mechanical testing simulations on each. Designs were rapid prototyped and tested using a custom vaginal phantom across a range of vaginal pressures and uterine tilts to select an optimal design. Two final designs were tested with fifteen volunteers to assess cervix visualization, comfort and usability compared to the speculum and the optimal design, the curved-tip inserter, was selected for testing in volunteers. Results We present a vaginal inserter as an alternative to the standard speculum for use with the POCkeT Colposcope. The device has a slim tubular body with a funnel-like curved tip measuring approximately 2.5 cm in diameter. The inserter has a channel through which a 2 megapixel (MP) mini camera with LED illumination fits to enable image capture. Mechanical finite element testing simulations with an applied pressure of 15 cm H2O indicated a high factor of safety (90.9) for the inserter. Testing of the device with a custom vaginal phantom, across a range of supine vaginal pressures and uterine tilts (retroverted, anteverted and sideverted), demonstrated image capture with a visual area comparable to the speculum for a normal/axial positioned uteri and significantly better than the speculum for anteverted and sideverted uteri (p<0.00001). Volunteer studies with self-insertion and physician-assisted cervix image capture showed adequate cervix visualization for 83% of patients. In addition, questionnaire responses from volunteers indicated a 92.3% overall preference for the inserter over the speculum and all indicated that the inserter was more comfortable than the speculum. The inserter provides a platform for self-cervical cancer screening and also enables acetic acid/Lugol’s iodine application and insertion of swabs for Pap smear sample collection. Conclusion This study demonstrates the feasibility of an inserter and miniature-imaging device for comfortable cervical image capture of women with potential for synergistic HPV and Pap smear sample collection. PMID:28562669
Electron-Beam Vapor Deposition of Mold Inserts Final Report CRADA No. TSB-777-94
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shepp, T.; Feeley, T.
Lawrence Livermore National Laboratory and H.G.G. Laser Fare, Inc. studied the application of electron-beam vapor deposition technology to the production of mold inserts for use in an injection molding machine by Laser Fare. Laser Fare provided LLNL with the requirements of the mold inserts as well as sample inserts. LLNL replicated the mold insert(s) to Laser Fare for testing by Laser Fare.
A bleached-kraft mill effluent fraction causing induction of a fish mixed-function oxygenase enzyme
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burnison, B.K.; Hodson, P.V.; Nuttley, D.J.
1996-09-01
Pulp mill effluents contain a myriad of chemicals that have the potential to cause deleterious effects on aquatic biota in receiving waters. Some of these chemicals evoke an acute lethal response of exposed biota while others evoke sublethal responses. One such sublethal response is the induction of mixed-function oxygenases (MFO) in fish, specifically the CYP1A1 enzyme ethoxy-resorufin-o-deethylase (EROD). Compounds causing MFO induction include congeners of polychlorinated biphenyls (PCBs), dioxins, furans, and polycyclic aromatic hydrocarbons (PAHs). The authors followed the partitioning of the inducing chemicals in pulp mill effluent fractions by Toxicity Identification Evaluation (TIE), or bioassay-driven chemical analysis. This proceduremore » was eventually modified to a more direct technique involving centrifugation, filtration, cleanup procedures, and C{sub 18} solid-phase adsorption. The extracts from the fractionation of two pulp mill effluents after secondary treatment were tested for EROD-inducing activity in a 4-d rainbow trout bioassay. The methanol extracts of particulates/colloids showed significant inducing capacity in Mill A effluent but not in Mill B effluent. The C{sub 18} methanol extracts induced activity from both effluents, with extracts from Mill A causing the greatest response. The particulate/colloidal extract (Mill A) was used as the source material for chemicals which caused EROD induction. The fraction was purified by solid-phase extraction techniques and reverse-phase high-performance liquid chromatography. The majority of the EROD activity was found in the moderately nonpolar region of the chromatogram (K{sub ow} = 4.6 to 5.1).« less
NASA Astrophysics Data System (ADS)
Hamran, Noramirah; Rashid, Azura A.
2017-07-01
Commercial fillers such as silica and carbon black generally impart the reinforcing effects in dry rubber compound, but have an adverse effect on Natural rubber (NR) latex compounds. The addition of commercial fillers in NR latex has reduced the mechanical properties of NR latex films due to the destabilization effect in the NR latex compounds which govern by the dispersion quality, particle size and also the pH of the dispersion itself. The ball milling process is the conventional meth od of preparation of dispersions and ultrasonic has successfully used in preparation of nano fillers such as carbon nanotube (CNT). In this study the combination between the conventional methods; ball milling together the ultrasonic method were used to prepare the silica and carbon black dispersions. The different duration of ball milling (24, 48 and 72 hours) was compared with the ultrasonic method (30, 60, 90 and 120 minutes). The combination of ball milling and ultrasonic from the optimum individual technique was used to investigate the reduction of particle size of the fillers. The particle size analyzer, transmission electron microscopy (TEM) and scanning electron microscopy (SEM) test were carried out to investigate the obtained particle size and the tensile and tear test were carried out to investigate the mechanical properties of the NR latex films. The reduction of filler particle size is expected to impart the properties of NR latex films.
An integrated CAD/CAM/robotic milling method for custom cementless femoral prostheses.
Wen-ming, Xi; Ai-min, Wang; Qi, Wu; Chang-hua, Liu; Jian-fei, Zhu; Fang-fang, Xia
2015-09-01
Aseptic loosening is the primary cause of cementless femoral prosthesis failure and is related to the primary stability of the cementless femoral prosthesis in the femoral cavity. The primary stability affects both the osseointegration and the long-term stability of cementless femoral prostheses. A custom cementless femoral prosthesis can improve the fit and fill of the prosthesis in the femoral cavity and decrease the micromotion of the proximal prosthesis such that the primary stability of the custom prosthesis can be improved, and osseointegration of the proximal prosthesis is achieved. These results will help to achieve long-term stability in total hip arthroplasty (THA). In this paper, we introduce an integrated CAD/CAM/robotic method of milling custom cementless femoral prostheses. The 3D reconstruction model uses femoral CT images and 3D design software to design a CAD model of the custom prosthesis. After the transformation matrices between two units of the robotic system are calibrated, consistency between the CAM software and the robotic system can be achieved, and errors in the robotic milling can be limited. According to the CAD model of the custom prosthesis, the positions of the robotic tool points are produced by the CAM software of the CNC machine. The normal vector of the three adjacent robotic tool point positions determines the pose of the robotic tool point. In conclusion, the fit rate of custom pig femur stems in the femoral cavities was 90.84%. After custom femoral prostheses were inserted into the femoral cavities, the maximum gaps between the prostheses and the cavities measured less than 1 mm at the diaphysis and 1.3 mm at the metaphysis. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raj K. Rajamani; Sanjeeva Latchireddi; Sravan K. Prathy
The U.S. mining industry operates approximately 80 semi-autogenesis grinding mills (SAG) throughout the United States. Depending on the mill size the SAG mills draws between 2 MW and 17 MW. The product from the SAG mill is further reduced in size using pebble crushers and ball mills. Hence, typical gold or copper ore requires between 2.0 and 7.5 kWh per ton of energy to reduce the particle size. Considering a typical mining operation processes 10,000 to 100,000 tons per day the energy expenditure in grinding is 50 percent of the cost of production of the metal. A research team frommore » the University of Utah is working to make inroads into saving energy in these SAG mills. In 2003, Industries of the Future Program of the Department of Energy tasked the University of Utah team to build a partnership between the University and the mining industry for the specific purpose of reducing energy consumption in SAG mills. A partnership was formed with Cortez Gold Mines, Kennecott Utah Copper Corporation, Process Engineering Resources Inc. and others. In the current project, Cortez Gold Mines played a key role in facilitating the 26-ft SAG mill at Cortez as a test mill for this study. According to plant personnel, there were a number of unscheduled shut downs to repair broken liners and the mill throughput fluctuated depending on ore type. The University team had two softwares, Millsoft and FlowMod to tackle the problem. Millsoft is capable of simulating the motion of charge in the mill. FlowMod calculates the slurry flow through the grate and pulp lifters. Based on this data the two models were fine-tuned to fit the Cortez SAG will. In the summer of 2004 a new design of shell lifters were presented to Cortez and in September 2004 these lifters were installed in the SAG mill. By December 2004 Cortez Mines realized that the SAG mill is drawing approximately 236-kW less power than before while maintaining the same level of production. In the first month there was extreme cycling and operators had to learn more. Now the power consumption is 0.3-1.3 kWh/ton lower than before. The actual SAG mill power draw is 230-370 kW lower. Mill runs 1 rpm lesser in speed on the average. The re-circulation to the cone crusher is reduced by 1-10%, which means more efficient grinding of critical size material is taking place in the mill. All of the savings have resulted in reduction of operating cost be about $0.023-$0.048/ ton.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richmann, D.L.; Luke, K.W.; Terry, J.C.
1984-07-01
The results of a study to determine the relative grindability of US limestones and to relate grindability to petrographic properties are presented in this report. A laboratory ball mill test was developed to provide a quick and simple measure of grindability. These values were then used to explore possible correlations between grindability and the chemical and physical properties of the limestones. Chemical analyses and thin section petrographic analyses were used to characterize the limestone samples. The results of the laboratory ball mill test were compared to the results of an industrial grinding test, the Bond Work Index, for six samplesmore » which covered the grindability range. The two tests compared well with a correlation coefficient greater than 0.9. While the laboratory test is not sufficient to provide ball mill design specifications, it can be used as a screening and quality control test. The grinding results, expressed as a grindability index, ranged in values from 2 to 15. This represents a seven-fold range in the relative difficulties to grind for the limestones tested. From the petrographic analysis results, a strong correlation was found between the grindability and the fraction of macrocrystalline (> 5 ..mu..m) carbonate minerals present in the limestone. However, based on the high degree of variability characteristic of most limestone deposits, petrographic information should, in general, only be used to qualitatively predict the grindability of a specific limestone. An actual grinding test is recommended for a quantitative evaluation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elmore, M.R.; Hartley, J.N.
A field test was conducted on a uranium tailings pile to evaluate the effectiveness of 15 chemical stabilizers for control of fugitive dust from uranium mill tailings. A tailings pile at the Federal American Partners (FAP) Uranium Mill, Gas Hills, Wyoming, was used for the field test. Preliminary laboratory tests using a wing tunnel were conducted to select the more promising stabilizers for field testing. Fourteen of the chemical stabilizers were applied with a field spray system pulled behind a tractor; one--Hydro Mulch--was applied with a hydroseeder. A portable weather station and data logger were installed to record the weathermore » conditions at the test site. After 1 year of monitoring (including three site visits), all of the stabilizers have degraded to some degree; but those applied at the manufacturers' recommended rate are still somewhat effective in reducing fugitive emissions. The following synthetic polymer emulsions appear to be the more effective stabilizers: Wallpol 40-133 from Reichold Chemicals, SP-400 from Johnson and March Corporation, and CPB-12 from Wen Don Corporation. Installed costs for the test plots ranged from $8400 to $11,300/ha; this range results from differences in stabilizer costs. Large-scale stabilization costs of the test materials are expected to range from $680 to $3600/ha based on FAP experience. Evaluation of the chemical stabilizers will continue for approximately 1 year. 2 references, 33 figures, 22 tables.« less
Liu, J Z; Zhao, J; Zhang, Y J
2016-02-01
To compare the effectiveness of the jaw thrust and the trapezius squeezing test(TST) for laryngeal mask airway (LMA) insertion in infants and children under sevoflurane anesthesia. A total of 100 children aged from 6 month to 3 years, American Society of Anesthesiologists(ASA) Ⅰ-Ⅱ and undergoing minor operation were enrolled from January to June 2015 in Tianjin Children's Hospital. The patients were randomly divided into jaw thrusting group (Group J, n=50)and trapezius squeezing group(Group T, n=50). Anesthesia was induced with sevoflurane. When children's eyelash reflex lose, jaw thrust/trapezius squeeze was applied every 15 seconds.It's considered that the depth of anesthesia was not enough, and test reaction was positive if any movements of body, limbs or toes were found at the point of test. Sevoflurane should be keep on inhalation until negative test reaction was appeared. Then LMA was inserted immediately.The time required for the negative test, end-tidal sevoflurane concentrations (ETsev), the index of Narcotrend anesthesia monitor(NT), the occurrence of gross purposeful movements, coughing, gagging, breath-holding, laryngospasm or an SpO2 < 90% during LMA insertion in two groups of patients were observed and recorded. The condition of LMA insertion and the rate of successful insertion were evaluated. The blood pressure(BP), heart rate(HR) and SpO2 were also recorded before and after LMA insertion. In group J and group T, the time required for the negative test was (2.31±1.03) vs (2.85±0.97)min(t=-2.462, P<0.05), ETsev was(3.25±1.02)% vs (3.81±0.87) %(t=-2.361, P<0.05), the depth of anesthesia NT index was(50.41±5.38) vs (41.32±4.92)(t=3.021, all P<0.05). All of above results were significantly different. The successful rate of the first attempt LMA insertion was 78% vs 100%(χ(2)=12.36 , P<0.01), respectively. The differences had statistical significance. The conditions of LMA insertion in group T were superior to those in group J. The incidences of gross purposeful movements, coughing, gagging, breath-holding and SpO2<90% during LMA insertion in group J were 20%, 16%, 10%, 14% and 8%, which were higher than those in group T (2%, 2%, 0, 2%, 0), the differences were significant(χ(2)=8.27, 5.98, 5.26, 4.89, 4.17, all P<0.05). No significant change in blood pressure, heart rate and SpO2 were found before and after inserting LMA in two groups. The trapezius squeezing test is a superior indicator of adequate condition for LMA insertion compared to the jaw thrust in infants and young children under sevoflurane anesthesia.
NASA Astrophysics Data System (ADS)
Soltani, Mohammadreza; Atrian, Amir
2018-02-01
This paper investigates the high-temperature tensile behavior of Al-SiC nanocomposite reinforced with 0, 1.5, and 3 vol% SiC nano particles. To fabricate the samples, SiC nano reinforcements and aluminum (Al) powders were milled using an attritor milling and then were cold pressed and hot extruded at 500 °C. Afterward, mechanical and microstructural characteristics were studied in different temperatures. To this end, tensile and compressive tests, micro-hardness test, microscopic examinations, and XRD analysis were performed. The results showed significant improvement of mechanical properties of Al-SiC nanocomposite in room temperature including 40% of ultimate tensile strength (UTS), 36% of ultimate compressive strength (UCS), and 44% of micro-hardness. Moreover, performing tensile tests at elevated temperatures (up to 270 °C) decreased the tensile strength by about 53%, 46%, and 45% for Al-0 vol% SiC, Al-1.5 vol% SiC, and Al-3 vol% SiC, respectively. This temperature rise also enhanced the elongation by about 11% and 133% for non-reinforced Al and Al-3 vol% SiC, respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1988-10-02
The 160-acre community of Mill Creek is located in Deerlodge County, Montana, immediately adjacent to the Anaconda Smelter NPL site. The community of Mill Creek has been contaminated for over 100 years with smelter emissions, fugitive emissions of flu dust at the smelter, and continued fugitive emissions emanating from adjacent highly contaminated soils. Settled flue emissions in the community of Mill Creek, from the now-defunct copper-smelting operation, contain arsenic, cadmium, and lead. Environmental siting of the community and biological testing of pre-school children, led EPA to conclude that contamination in the Mill Creek area poses an imminent and substantial endangermentmore » to the health of individuals residing there. The primary contaminant of concern at this site is arsenic. Cadmium and lead are secondary contaminants of concern. The selected remedial action for the site includes: permanent relocation of all residents (8 homes) with temporary erosional stabilization of disturbed areas by establishing and maintaining a vegetative cover; demolition, consolidation, and storage.« less
Reaction bonded silicon nitride prepared from wet attrition-milled silicon. [fractography
NASA Technical Reports Server (NTRS)
Herball, T. P.; Glasgow, T. K.; Shaw, N. J.
1980-01-01
Silicon powder wet milled in heptane was dried, compacted into test bar shape, helium-sintered, and then reaction bonded in nitrogen-4 volume percent hydrogen. As-nitrided bend strengths averaged approximately 290 MPa at both room temperature and 1400 C. Fracture initiation appeared to be associated with subsurface flaws in high strength specimens and both subsurface and surface flaws in low strength specimens.
Reaction bonded silicon nitride prepared from wet attrition-milled silicon
NASA Technical Reports Server (NTRS)
Herbell, T. P.; Glasgow, T. K.; Shaw, N. J.
1980-01-01
Silicon powder wet milled in heptane was dried, compacted into test bar shape, helium-sintered, and then reaction bonded in nitrogen-4 vol% hydrogen. As-nitrided bend strengths averaged approximately 290 MPa at both room temperature and 1400 C. Fracture initiation appeared to be associated with subsurface flaws in high-strength specimens and both subsurface and surface flaws in low-strength specimens.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martz, J.E.; Ratajczak, A.F.; Delombard, R.
1982-02-01
The first two years of operation of a stand alone photovoltaic (PV) power system for the village of Tangaye, Upper Volta in West Africa are described. The purpose of the experiment was to demonstrate that PV systems could provide reliable electrical power for multiple use applications in remote areas where local technical expertise is limited. The 1.8 kW (peak) power system supplies 120-V (d.c.) electrical power to operate a grain mill, a water pump, and mill building lights for the village. The system was initially sized to pump a part of the village water requirements from an existing improved well,more » and to meet a portion of the village grain grinding requirements. The data, observations, experiences, and conclusions developed during the first two years of operation are discussed. Reports of tests of the mills used in the project are included.« less
Retrieving Storm Electric Fields from Aircraft Field Mill Data. Part 1; Theory
NASA Technical Reports Server (NTRS)
Koshak, W. J.
2006-01-01
It is shown that the problem of retrieving storm electric fields from an aircraft instrumented with several electric field mill sensors can be expressed in terms of a standard Lagrange multiplier optimization problem. The method naturally removes aircraft charge from the retrieval process without having to use a high voltage stinger and linearly combined mill data values. It allows a variety of user-supplied physical constraints (the so-called side constraints in the theory of Lagrange multipliers) and also helps improve absolute calibration. Additionally, this paper introduces an alternate way of performing the absolute calibration of an aircraft that has some benefits over conventional analyses. It is accomplished by using the time derivatives of mill and pitch data for a pitch down maneuver performed at high (greater than 1 km) altitude. In Part II of this study, the above methods are tested and then applied to complete a full calibration of a Citation aircraft.
Retrieving Storm Electric Fields From Aircraft Field Mill Data. Part I: Theory
NASA Technical Reports Server (NTRS)
Koshak, W. J.
2005-01-01
It is shown that the problem of retrieving storm electric fields from an aircraft instrumented with several electric field mill sensors can be expressed in terms of a standard Lagrange multiplier optimization problem. The method naturally removes aircraft charge from the retrieval process without having to use a high voltage stinger and linearly combined mill data values. It also allows a variety of user-supplied physical constraints (the so-called side constraints in the theory of Lagrange multipliers). Additionally, this paper introduces a novel way of performing the absolute calibration of an aircraft that has several benefits over conventional analyses. In the new approach, absolute calibration is completed by inspecting the time derivatives of mill and pitch data for a pitch down maneuver performed at high (greater than 1 km) altitude. In Part II of this study, the above methods are tested and then applied to complete a full calibration of a Citation aircraft.
Massin, N; Bohadana, A B; Wild, P; Kolopp-Sarda, M N; Toamain, J P
1995-06-01
Our goal was to assess the relation between dust exposure levels and the respiratory health status of workers in grain and flour mills in eastern France. We studied 118 male workers from 11 mills and 164 unexposed male controls. Dust concentration was measured by personal sampling methods. Outcome variables included respiratory symptoms, routine pulmonary function tests, and indices of airway responsiveness to methacholine. A great within- and between-area variability of inhalable dust concentration was found in all mills. A dose-response relationship was observed between dust exposure levels and chronic respiratory symptoms, suggesting that exposure to grain and flour dust may lead to chronic bronchitis. A significant relation was found between dust exposure and airway hyper-responsiveness; this finding is important since it has been hypothesized that the latter abnormality may lead to or be a predisposing factor in subsequent chronic, irreversible airflow obstruction.
NASA Technical Reports Server (NTRS)
Martz, J. E.; Ratajczak, A. F.; Delombard, R.
1982-01-01
The first two years of operation of a stand alone photovoltaic (PV) power system for the village of Tangaye, Upper Volta in West Africa are described. The purpose of the experiment was to demonstrate that PV systems could provide reliable electrical power for multiple use applications in remote areas where local technical expertise is limited. The 1.8 kW (peak) power system supplies 120-V (d.c.) electrical power to operate a grain mill, a water pump, and mill building lights for the village. The system was initially sized to pump a part of the village water requirements from an existing improved well, and to meet a portion of the village grain grinding requirements. The data, observations, experiences, and conclusions developed during the first two years of operation are discussed. Reports of tests of the mills used in the project are included.
ERIC Educational Resources Information Center
Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.
The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…
Manoogian, Sarah; Lee, Adam K; Widmaier, James C
2017-08-01
No studies have assessed the effects of parameters associated with insertion temperature in modern self-drilling external fixation pins. The current study assessed how varying the presence of irrigation, insertion speed, and force impacted the insertion temperatures of 2 types of standard and self-drilling external fixation half pins. Seventy tests were conducted with 10 trials for 4 conditions on self-drilling pins, and 3 conditions for standard pins. Each test used a thermocouple inside the pin to measure temperature rise during insertion. Adding irrigation to the standard pin insertion significantly lowered the maximum temperature (P <0.001). Lowering the applied force for the standard pin did not have a significant change in temperature rise. Applying irrigation during the self-drilling pin tests dropped average rise in temperature from 151.3 ± 21.6°C to 124.1 ± 15.3°C (P = 0.005). When the self-drilling pin insertion was decreased considerably from 360 to 60 rpm, the temperature decreased significantly from 151.3 ± 21.6°C to 109.6 ± 14.0°C (P <0.001). When the force applied increased significantly, the corresponding self-drilling pin temperature increase was not significant. The standard pin had lower peak temperatures than the self-drilling pin for all conditions. Moreover, slowing down the insertion speed and adding irrigation helped mitigate the temperature increase of both pin types during insertion.
Validation of a Projection-domain Insertion of Liver Lesions into CT Images
Chen, Baiyu; Ma, Chi; Leng, Shuai; Fidler, Jeff L.; Sheedy, Shannon P.; McCollough, Cynthia H.; Fletcher, Joel G.; Yu, Lifeng
2016-01-01
Rationale and Objectives The aim of this study was to validate a projection-domain lesion-insertion method with observer studies. Materials and Methods A total of 51 proven liver lesions were segmented from computed tomography images, forward projected, and inserted into patient projection data. The images containing inserted and real lesions were then reconstructed and examined in consensus by two radiologists. First, 102 lesions (51 original, 51 inserted) were viewed in a randomized, blinded fashion and scored from 1 (absolutely inserted) to 10 (absolutely real). Statistical tests were performed to compare the scores for inserted and real lesions. Subsequently, a two-alternative-forced-choice test was conducted, with lesions viewed in pairs (real vs. inserted) in a blinded fashion. The radiologists selected the inserted lesion and provided a confidence level of 1 (no confidence) to 5 (completely certain). The number of lesion pairs that were incorrectly classified was calculated. Results The scores for inserted and proven lesions had the same median (8) and similar interquartile ranges (inserted, 5.5–8; real, 6.5–8). The means scores were not significantly different between real and inserted lesions (P value = 0.17). The receiver operating characteristic curve was nearly diagonal, with an area under the curve of 0.58 ± 0.06. For the two-alternative-forced-choice study, the inserted lesions were incorrectly identified in 49% (25 out of 51) of pairs; radiologists were incorrect in 38% (3 out of 8) of pairs even when they felt very confident in identifying the inserted lesion (confidence level ≥4). Conclusions Radiologists could not distinguish between inserted and real lesions, thereby validating the lesion-insertion technique, which may be useful for conducting virtual clinical trials to optimize image quality and radiation dose. PMID:27432267
Wang, Tong-Mei; Lee, Ming-Shu; Wang, Juo-Song; Lin, Li-Deh
2015-01-01
This study investigated the effect of implant design and bone quality on insertion torque (IT), implant stability quotient (ISQ), and insertion energy (IE) by monitoring the continuous change in IT and ISQ while implants were inserted in artificial bone blocks that simulate bone of poor or poor-to-medium quality. Polyurethane foam blocks (Sawbones) of 0.16 g/cm³ and 0.32 g/cm³ were respectively used to simulate low density and low- to medium-density cancellous bone. In addition, some test blocks were laminated with a 1-mm 0.80 g/cm³ polyurethane layer to simulate cancellous bone with a thin cortical layer. Four different implants (Nobel Biocare Mk III-3.75, Mk III-4.0, Mk IV-4.0, and NobelActive-4.3) were placed into the different test blocks in accordance with the manufacturer's instructions. The IT and ISQ were recorded at every 0.5-mm of inserted length during implant insertion, and IE was calculated from the torque curve. The peak IT (PIT), final IT (FIT), IE, and final ISQ values were statistically analyzed. All implants showed increasing ISQ values when the implant was inserted more deeply. In contrast to the ISQ, implants with different designs showed dissimilar IT curve patterns during the insertion. All implants showed a significant increase in the PIT, FIT, IE, and ISQ when the test-block density increased or when the 1-mm laminated layer was present. Tapered implants showed FIT or PIT values of more than 40 Ncm for all of the laminated test blocks and for the nonlaminated test blocks of low to medium density. Parallel-wall implants did not exhibit PIT or FIT values of more than 40 Ncm for all of the test blocks. NobelActive-4.3 showed a significantly higher FIT, but a significantly lower IE, than Mk IV-4.0. While the existence of cortical bone or implant designs significantly affects the dynamic IT profiles during implant insertion, it does not affect the ISQ to a similar extent. Certain implant designs are more suitable than others if high IT is required in bone of poor quality. The manner in which IT, IE, and ISQ represent the implant primary stability requires further study.
Ergonomics assessment of composite ballistic inserts for bullet- and fragment-proof vests.
Majchrzycka, Katarzyna; Brochocka, Agnieszka; Luczak, Anna; Lężak, Krzysztof
2013-01-01
Personal protective equipment worn by uniformed services (e.g., the police and the military) must ensure protection against bodily injuries. However, a high degree of protection is always associated with significant discomfort. This article presents the results of an assessment of the ergonomics parameters of new special purpose products, ballistic inserts with improved ballistic resistance, and an assessment of the impact of the burden related to their use on the psychomotor performance of the subjects. An obstacle course and subjective ergonomics assessment questionnaires were used in tests. Thermal discomfort was also assessed. Psychological testing included tests enabling an assessment of the subjects' cognitive and psychomotor performance, and a subjective assessment of mental load. The tests did not show any decrease in the comfort of use of the new inserts with improved ballistic resistance compared to the inserts currently used.
Lee, Wan-Sun; Kim, Woong-Chul
2015-01-01
PURPOSE To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. MATERIALS AND METHODS Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (α=.05), respectively. RESULTS The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). CONCLUSION Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (<120 µm). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced. PMID:25932310
Park, Jong-Kyoung; Lee, Wan-Sun; Kim, Hae-Young; Kim, Woong-Chul; Kim, Ji-Hwan
2015-04-01
To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (α=.05), respectively. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (<120 µm). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.
Coliform Bacteria and Nitrogen Fixation in Pulp and Paper Mill Effluent Treatment Systems
Gauthier, Francis; Neufeld, Josh D.; Driscoll, Brian T.; Archibald, Frederick S.
2000-01-01
The majority of pulp and paper mills now biotreat their combined effluents using activated sludge. On the assumption that their wood-based effluents have negligible fixed N, and that activated-sludge microorganisms will not fix significant N, these mills routinely spend large amounts adding ammonia or urea to their aeration tanks (bioreactors) to permit normal biomass growth. N2 fixation in seven Eastern Canadian pulp and paper mill effluent treatment systems was analyzed using acetylene reduction assays, quantitative nitrogenase (nifH) gene probing, and bacterial isolations. In situ N2 fixation was undetectable in all seven bioreactors but was present in six associated primary clarifiers. One primary clarifier was studied in greater detail. Approximately 50% of all culturable cells in the clarifier contained nifH, of which >90% were Klebsiella strains. All primary-clarifier coliform bacteria growing on MacConkey agar were identified as klebsiellas, and all those probed contained nifH. In contrast, analysis of 48 random coliform isolates from other mill water system locations showed that only 24 (50%) possessed the nifH gene, and only 13 (27%) showed inducible N2-fixing activity. Thus, all the pulp and paper mill primary clarifiers tested appeared to be sites of active N2 fixation (0.87 to 4.90 mg of N liter−1 day−1) and a microbial community strongly biased toward this activity. This may also explain why coliform bacteria, especially klebsiellas, are indigenous in pulp and paper mill water systems. PMID:11097883
Bakker, Theo C M; Giger, Thomas; Frommen, Joachim G; Largiadèr, Carlo R
2017-08-01
There is a need for rapid and reliable molecular sexing of three-spined sticklebacks, Gasterosteus aculeatus, the supermodel species for evolutionary biology. A DNA region at the 5' end of the sex-linked microsatellite Gac4202 was sequenced for the X chromosome of six females and the Y chromosome of five males from three populations. The Y chromosome contained two large insertions, which did not recombine with the phenotype of sex in a cross of 322 individuals. Genetic variation (SNPs and indels) within the insertions was smaller than on flanking DNA sequences. Three molecular PCR-based sex tests were developed, in which the first, the second or both insertions were covered. In five European populations (from DE, CH, NL, GB) of three-spined sticklebacks, tests with both insertions combined showed two clearly separated bands on agarose minigels in males and one band in females. The tests with the separate insertions gave similar results. Thus, the new molecular sexing method gave rapid and reliable results for sexing three-spined sticklebacks and is an improvement and/or alternative to existing methods.
Vachhani, Raj; Patel, Toral; Centor, Robert M; Estrada, Carlos A
2017-01-01
Meta-analyses based on peer-reviewed publications report a sensitivity of approximately 85% for rapid antigen streptococcus tests to diagnose group A streptococcal (GAS) pharyngitis. Because these meta-analyses excluded package inserts, we examined the test characteristics of rapid antigen streptococcal tests and molecular methods that manufacturers report in their package inserts. We included tests available in the US market (Food and Drug Administration, period searched 1993-2015) and used package insert data to calculate pooled sensitivity and specificity. To examine quality, we used the Quality Assessment of Diagnostic Accuracy Studies-2. We excluded 26 tests having different trade names but identical methods and data. The study design was prospective in 41.7% (10 of 24). The pooled sensitivity of the most commonly used method, lateral flow/immunochromatographic, was 95% (95% confidence interval [CI] 94-96) and the pooled specificity was 98% (96-98); 7108 patients. The pooled sensitivity of the polymerase chain reaction or molecular methods was 98% (95% CI 96-98) and the pooled specificity was 96% (95% CI 95-97); 5685 patients. Package inserts include sponsored studies that overestimate the sensitivity of rapid tests to diagnose GAS pharyngitis by approximately 10%. Physicians should understand that package inserts overestimate diagnostic test utility; a negative test cannot be used to exclude GAS pharyngitis.
NASA Astrophysics Data System (ADS)
Takano, Naoki; Tachikawa, Hiroto; Miyano, Takaya; Nishiyabu, Kazuaki
Aiming at the practical use of polyethylene glycol (PEG) microneedles for transdermal drug delivery system (DDS), a testing apparatus for their insertion into cultured human skin has been developed. To simulate the variety of conditions of human skin, biaxial tension can be applied to the cultured human skin. An adopted testing scheme to apply and control the biaxial tension is similar to the deep-draw forming technique. An attention was also paid to the short-time setup of small, thin and wet cultured skin. One dimensional array with four needles was inserted and influence of tension was discussed. It was found that tension, deflection of skin during insertion and original curvature of skin are the important parameters for microneedles array design.
An evaluation of the urban stormwater pollutant removal efficiency of catch basin inserts.
Morgan, Robert A; Edwards, Findlay G; Brye, Kristofor R; Burian, Stephen J
2005-01-01
In a storm sewer system, the catch basin is the interface between surface runoff and the sewer. Responding to the need to improve the quality of stormwater from urban areas and transportation facilities, and spurred by Phase I and II Stormwater Rules from the U.S. Environmental Protection Agency, several companies market catch basin inserts as best management practices for urban water quality management. However, little data have been collected under controlled tests that indicate the pollutant removal efficiency of these inserts when the inflow is near what can be expected to occur in the field. A stormwater simulator was constructed to test inserts under controlled and replicable conditions. The inserts were tested for removal efficiency of total suspended solids (TSS) and total petroleum hydrocarbons (TPH) at an inflow rate of 757 to 814 L/min, with influent pollutant concentrations of 225 mg/L TSS and 30 mg/L TPH. These conditions are similar to stormwater runoff from small commercial sites in the southeastern United States. Results from the tests indicate that at the test flowrate and pollutant concentration, average TSS removal efficiencies ranged from 11 to 42% and, for TPH, the removal efficiency ranged from 10 to 19%.
Lyu, Honghong; Gao, Bin; He, Feng; Zimmerman, Andrew R; Ding, Cheng; Huang, Hua; Tang, Jingchun
2018-02-01
With the goal of combining the advantages of ball-milling and biochar technologies, a variety of ball-milled biochars (BM-biochars) were synthesized, characterized, and tested for nickel (Ni(II)) removal from aqueous solution. Ball milling increased only the external surface area of low temperature biochars, but still dramatically enhanced their ability to sorb aqueous Ni(II). For higher temperature biochars with relatively low surface area, ball milling increased both external and internal surface area. Measurements of pH, zeta potential, stability, and Boehm titration demonstrated that ball milling also added oxygen-containing functional groups (e.g., carboxyl, lactonic, and hydroxyl) to biochar's surface. With these changed, all the BM-biochars showed much better Ni(II) removal efficiency than unmilled biochars. Ball-milled 600 °C bagasse biochar (BMBG600) showed the greatest Ni(II) adsorption capacity (230-650 compared to 26-110 mmol/kg for unmilled biochar) and the adsorption was dosage and pH dependent. Compared with the unmilled biochar, BMBG600 also displayed faster adsorption kinetics, likely due to an increase in rates of intra-particle diffusion in the latter. Experimental and modeling results suggest that the increase in BM-biochar's external and internal surface areas exposed its graphitic structure, thus enhancing Ni(II) adsorption via strong cation-π interaction. In addition, the increase in acidic surface functional groups enhanced Ni(II) adsorption by BM-biochar via electrostatic interaction and surface complexation. Ball milling thus has great potential to increase the efficiency of environmentally friendly biochar for various environmental applications. Copyright © 2017 Elsevier Ltd. All rights reserved.
Long lifetime hollow cathodes for 30-cm mercury ion thrusters
NASA Technical Reports Server (NTRS)
Mirtich, M. J.; Kerslake, W. R.
1976-01-01
An experimental investigation of hollow cathodes for 30-cm Hg bombardment thrusters was carried out. Both main and neutralizer cathode configurations were tested with both rolled foil inserts coated with low work function material and impregnated porous tungsten inserts. Temperature measurements of an impregnated insert at various positions in the cathode were made. These, along with the cathode thermal profile are presented. A theory for rolled foil and impregnated insert operation and lifetime in hollow cathodes is developed. Several endurance tests, as long as 18000 hours at emission currents of up to 12 amps were attained with no degradation in performance.
Grinding Si3N4 Powder In Si3N4 Equipment
NASA Technical Reports Server (NTRS)
Herbell, Thomas P.; Freedman, Marc R.; Kiser, James D.
1989-01-01
Three methods of grinding compared. Report based on study of grinding silicon nitride powder in preparation for sintering into solid ceramic material. Attrition, vibratory, and ball mills lined with reaction-bonded silicon nitride tested. Rates of reduction of particle sizes and changes in chemical compositions of powders measured so grinding efficiences and increases in impurity contents from wear of mills and media evaluated for each technique.
Jones, Andrew P; Hoffmann, Jeffrey W; Smith, Dennis N; Feeley, Thomas J; Murphy, James T
2007-02-15
Based on results of field testing conducted by the U.S. Department of Energy's National Energy Technology Laboratory (DOE/NETL), this article provides preliminary costs for mercury control via conventional activated carbon injection (ACI), brominated ACI, and conventional ACI coupled with the application of a sorbent enhancement additive (SEA) to coal prior to combustion. The economic analyses are reported on a plant-specific basis in terms of the cost required to achieve low (50%), mid (70%), and high (90%) levels of mercury removal "above and beyond" the baseline mercury removal achieved by existing emission control equipment. In other words, the levels of mercury control are directly attributable to ACI. Mercury control costs via ACI have been amortized on a current dollar basis. Using a 20-year book life, levelized costs for the incremental increase in cost of electricity (COE), expressed in mills per kilowatt-hour (mills/kWh), and the incremental cost of mercury control, expressed in dollars per pound of mercury removed ($/lb Hg removed), have been calculated for each level of ACI mercury control. For this analysis, the increase in COE varied from 0.14 mills/kWh to 3.92 mills/kWh. Meanwhile, the incremental cost of mercury control ranged from $3810/lb Hg removed to $166000/lb Hg removed.
Svečko, Rajko; Kusić, Dragan; Kek, Tomaž; Sarjaš, Andrej; Hančič, Aleš; Grum, Janez
2013-05-14
This paper presents an improved monitoring system for the failure detection of engraving tool steel inserts during the injection molding cycle. This system uses acoustic emission PZT sensors mounted through acoustic waveguides on the engraving insert. We were thus able to clearly distinguish the defect through measured AE signals. Two engraving tool steel inserts were tested during the production of standard test specimens, each under the same processing conditions. By closely comparing the captured AE signals on both engraving inserts during the filling and packing stages, we were able to detect the presence of macro-cracks on one engraving insert. Gabor wavelet analysis was used for closer examination of the captured AE signals' peak amplitudes during the filling and packing stages. The obtained results revealed that such a system could be used successfully as an improved tool for monitoring the integrity of an injection molding process.
Svečko, Rajko; Kusić, Dragan; Kek, Tomaž; Sarjaš, Andrej; Hančič, Aleš; Grum, Janez
2013-01-01
This paper presents an improved monitoring system for the failure detection of engraving tool steel inserts during the injection molding cycle. This system uses acoustic emission PZT sensors mounted through acoustic waveguides on the engraving insert. We were thus able to clearly distinguish the defect through measured AE signals. Two engraving tool steel inserts were tested during the production of standard test specimens, each under the same processing conditions. By closely comparing the captured AE signals on both engraving inserts during the filling and packing stages, we were able to detect the presence of macro-cracks on one engraving insert. Gabor wavelet analysis was used for closer examination of the captured AE signals' peak amplitudes during the filling and packing stages. The obtained results revealed that such a system could be used successfully as an improved tool for monitoring the integrity of an injection molding process. PMID:23673677
Krug, Klaus-Peter; Knauber, Andreas W; Nothdurft, Frank P
2015-03-01
The aim of this study was to investigate the fracture behavior of metal-ceramic bridges with frameworks from cobalt-chromium-molybdenum (CoCrMo), which are manufactured using conventional casting or a new computer-aided design/computer-aided manufacturing (CAD/CAM) milling and sintering technique. A total of 32 metal-ceramic fixed dental prostheses (FDPs), which are based on a nonprecious metal framework, was produced using a conventional casting process (n = 16) or a new CAD/CAM milling and sintering process (n = 16). Eight unveneered frameworks were manufactured using each of the techniques. After thermal and mechanical aging of half of the restorations, all samples were subjected to a static loading test in a universal testing machine, in which acoustic emission monitoring was performed. Three different critical forces were revealed: the fracture force (F max), the force at the first reduction in force (F decr1), and the force at the critical acoustic event (F acoust1). With the exception of the veneered restorations with cast or sintered metal frameworks without artificial aging, which presented a statistically significant but slightly different F max, no statistically significant differences between cast and CAD/CAM sintered and milled FDPs were detected. Thermal and mechanical loading did not significantly affect the resulting forces. Cast and CAD/CAM milled and sintered metal-ceramic bridges were determined to be comparable with respect to the fracture behavior. FDPs based on CAD/CAM milled and sintered frameworks may be an applicable and less technique-sensitive alternative to frameworks that are based on conventionally cast frameworks.
How Do Health Care Providers Diagnose Phenylketonuria (PKU)?
... born with PKU. To perform this test, a health care provider takes some cells, either through a needle inserted into the abdomen or a small tube inserted into the vagina. A genetic counselor who understands the risks and benefits of genetic testing can help explain the choices available for testing. ...
49 CFR Appendix E to Part 227 - Use of Insert Earphones for Audiometric Testing
Code of Federal Regulations, 2010 CFR
2010-10-01
... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION OCCUPATIONAL NOISE EXPOSURE Pt. 227, App. E Appendix.... B. Technicians who conduct audiometric tests must be trained to insert the earphones correctly into... audiometer. IV. Background Noise Levels Testing shall be conducted in a room where the background ambient...
NASA Technical Reports Server (NTRS)
Fisher, Bruce D.; Phillips, Michael R.; Maier, Launa M.
1992-01-01
A NASA Langley Research Center Learjet 28 research airplane was flown in various adverse weather conditions in the vicinity of the NASA Kennedy Space Center from 1990-1992 to measure airborne electric fields during the Joint NASA/USAF Airborne Field Mill Program. The objective of this program was to characterize the electrical activity in various weather phenomena common to the NASA-Kennedy area in order to refine Launch Commit Criteria for natural and triggered lightning. The purpose of the program was to safely relax the existing launch commit criteria, thereby increasing launch availability and reducing the chance for weather holds and delays. This paper discusses the operational conduct of the flight test, including environmental/safety considerations, aircraft instrumentation and modification, test limitations, flight procedures, and the procedures and responsibilities of the personnel in the ground station. Airborne field mill data were collected for all the Launch Commit Criteria during two summer and two winter deployments. These data are now being analyzed.
MTR MAIN FLOOR. MEN DEMONSTRATE INSERTION OF DUMMY PLUG INTO ...
MTR MAIN FLOOR. MEN DEMONSTRATE INSERTION OF DUMMY PLUG INTO AN MTR BEAM HOLE. ONE MAN CHECKS RADIATION LEVEL AT THE END OF THE UNIVERSAL COFFIN, WHILE ANOTHER USES TOOL TO INSERT PLUG INTO HOLE THROUGH COFFIN. MEN WEAR "ANTI-C" (ANTI-CONTAMINATION) CLOTHING. INL NEGATIVE NO. 6198. R.G. Larsen, Photographer, 6/27/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Roch, Toralf; Krüger, Anne; Kratz, Karl; Ma, Nan; Jung, Friedrich; Lendlein, Andreas
2012-01-01
For the successful clinical and biological application of polymers, their interaction with cells, tissues, and body fluids has to be well characterized. In order to investigate how the physical, chemical, and mechanical properties of candidate biomaterials influence cell behaviours, the testing sample is usually placed in commercially available cell culture plates. Thus, not only the testing sample itself but also the culture dish material might influence the cell behaviour. Therefore, an insert system was created to exclude this influence and allow investigations of the testing material solely. In this study micropatterned inserts prepared from polystyrene (PS) as well as from poly(ether imide) (PEI) with three different roughness levels of i) Rq = 0.29 μm (PS) and 0.23 μm (PEI); ii) Rq = 3.47 μm (PS) and 3.92 μm (PEI); and iii) Rq = 22.16 μm [corrected] (PS) and 22.65 μm (PEI) were explored with regard of their immuno-compatibility including the determination of potential contaminations with endotoxins or other microbial products. The endotoxin levels of the inserts were determined to be less than 0.07 EU/mL, which is well below the U.S. Food and Drug Administration limit of 0.5 EU/mL and the survival of murine macrophages cultured in the inserts was not impaired. Activation of early immune mechanisms such as complement activation and the generation of reactive oxygen species could not be observed. All tested materials had no influence on the cytokine secretion from cells of whole human blood. The investigated inserts were immuno-compatible and apparently free of contaminations with microbial products. The roughness of the inserts had no stimulatory or inhibitory effect on early immune mechanisms. Conclusively, the 24-well plate insert systems introduced in this study allow investigating the interactions of tailored surface properties such as roughness with many other cell types, without the disadvantage of the standard commercially available culture vessels influencing the biomaterial testing.
Insertion Loss of Personal Protective Clothing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shull D.J.; Biesel, V.B.; Cunefare, K.A.
1999-05-13
'The use of personal protective clothing that covers the head is a common practice in many industries. Such personal protective clothing will impact the sound pressure level and the frequency content of sounds to which the wearer will be exposed. The use of such clothing, then, may impact speech and alarm audibility. A measure of the impact of such clothing is its insertion loss. Insertion loss measurements were performed on four types of personal protective clothing in use by Westinghouse Savannah River Company personnel which utilize cloth and plastic hood configurations to protect the head. All clothing configurations tested atmore » least partially cover the ears. The measurements revealed that insertion loss of the items tested was notable at frequencies above 1000 Hz only and was a function of material stiffness and acoustic flanking paths to the ear. Further, an estimate of the clothing''s noise reduction rating reveals poor performance in that regard, even though the insertion loss of the test articles was significant at frequencies at and above 1000 Hz.'« less
Fidler, Richard E.
1971-01-01
Mill Creek valley is part of the greater Cincinnati industrial area in southwestern Ohio. In 1964, nearly 30 percent of the water supply in the study area of about 27 square miles was obtained from wells in the glacial-outwash aquifer underlying the valley. Ground-water demand has increased steadily since the late 1800's, and excessive pumpage during the years of World War II caused water levels to decline to critical levels. Natural recharge to the aquifer, from precipitation, is about 8.5 mgd (million gallons per day). In 1964, the total water use was about 30 mgd, of which 8.1 mgd was obtained from wells in Mill Creek valley, and the remainder was imported from outside the basin. With rapid industrial expansion and population growth, demand for ground water is continuing to increase. By the year 2000 ground-water pumpage is expected to exceed 25 mgd. At a public hearing before the Ohio Water Commission in 1961, artificial recharge of the aquifer through injection wells was proposed as a possible solution to the Mill Creek valley water-supply problem. The present study attempts to determine the feasibility of injection-well recharge systems in the Mill Creek valley. Although basically simple, the hydrologic system in Mill Creek valley is complex in detail and is difficult to evaluate using conventional quantitative methods. Because of this complexity, an electric analog model was used to test specific development plans. Three hypothetical pumping plans were developed by projecting past pumpage data to the years 1980 and 2000. Various combinations of injection wells were tested on the model under different hypothetical conditions of pumpage. Based on analog model analysis, from three to eight inject-ion wells, with an approximate input of 2 mgd each, would reverse the trend in declining groundwater levels and provide adequate water to meet anticipated future demands.
Xu, Wei; Li, Ming; Wen, Cuie; Lv, Shaomin; Liu, Chengcheng; Lu, Xin
2018-01-01
A biocompatible Ti-28Nb-35.4Zr alloy used as bone implant was fabricated through the powder metallurgy process. The effects of mechanical milling and sintering temperatures on the microstructure and mechanical properties were investigated systematically, before in vitro biocompatibility of full dense Ti-28Nb-35.4Zr alloy was evaluated by cytotoxicity tests. The results show that the mechanical milling and sintering temperatures have significantly effects on the density and mechanical properties of the alloys. The relative density of the alloy fabricated by the atomized powders at 1500 °C is only 83 ± 1.8%, while the relative density of the alloy fabricated by the ball-milled powders can rapidly reach at 96.4 ± 1.3% at 1500 °C. When the temperature was increased to 1550 °C, the alloy fabricated by ball-milled powders achieve full density (relative density is 98.1 ± 1.2%). The PM-fabricated Ti-28Nb-35.4Zr alloy by ball-milled powders at 1550 °C can achieve a wide range of mechanical properties, with a compressive yield strength of 1058 ± 35.1 MPa, elastic modulus of 50.8 ± 3.9 GPa, and hardness of 65.8 ± 1.5 HRA. The in vitro cytotoxicity test suggests that the PM-fabricated Ti-28Nb-35.4Zr alloy by ball-milled powders at 1550 °C has no adverse effects on MC3T3-E1 cells with cytotoxicity ranking of 0 grade, which is nearly close to ELI Ti-6Al-4V or CP Ti. These properties and the net-shape manufacturability makes PM-fabricated Ti-28Nb-35.4Zr alloy a low-cost, highly-biocompatible, Ti-based biomedical alloy. PMID:29601517
Insert Design and Manufacturing for Foam-Core Composite Sandwich Structures
NASA Astrophysics Data System (ADS)
Lares, Alan
Sandwich structures have been used in the aerospace industry for many years. The high strength to weight ratios that are possible with sandwich constructions makes them desirable for airframe applications. While sandwich structures are effective at handling distributed loads such as aerodynamic forces, they are prone to damage from concentrated loads at joints or due to impact. This is due to the relatively thin face-sheets and soft core materials typically found in sandwich structures. Carleton University's Uninhabited Aerial Vehicle (UAV) Project Team has designed and manufactured a UAV (GeoSury II Prototype) which features an all composite sandwich structure fuselage structure. The purpose of the aircraft is to conduct geomagnetic surveys. The GeoSury II Prototype serves as the test bed for many areas of research in advancing UAV technologies. Those areas of research include: low cost composite materials manufacturing, geomagnetic data acquisition, obstacle detection, autonomous operations and magnetic signature control. In this thesis work a methodology for designing and manufacturing inserts for foam-core sandwich structures was developed. The results of this research work enables a designer wishing to design a foam-core sandwich airframe structure, a means of quickly manufacturing optimized inserts for the safe introduction of discrete loads into the airframe. The previous GeoSury II Prototype insert designs (v.1 & v.2) were performance tested to establish a benchmark with which to compare future insert designs. Several designs and materials were considered for the new v.3 inserts. A plug and sleeve design was selected, due to its ability to effectively transfer the required loads to the sandwich structure. The insert material was chosen to be epoxy, reinforced with chopped carbon fibre. This material was chosen for its combination of strength, low mass and also compatibility with the face-sheet material. The v.3 insert assembly is 60% lighter than the previous insert designs. A casting process for manufacturing the v.3 inserts was developed. The developed casting process, when producing more than 13 inserts, becomes more economical than machining. An exploratory study was conducted looking at the effects of dynamic loading on the v.3 insert performance. The results of this study highlighted areas for improving dynamic testing of foam-core sandwich structure inserts. Correlations were developed relating design variables such as face-sheet thickness and insert diameter to a failure load for different load cases. This was done through simulations using Computer Aided Engineering (CAE) software, and experimental testing. The resulting correlations were integrated into a computer program which outputs the required insert dimensions given a set of design parameters, and load values.
Magnetic properties of NdFeB-coated rubberwood composites
NASA Astrophysics Data System (ADS)
Noodam, Jureeporn; Sirisathitkul, Chitnarong; Matan, Nirundorn; Rattanasakulthong, Watcharee; Jantaratana, Pongsakorn
2013-01-01
Magnetic properties of composites prepared by coating lacquer containing neodymium iron boron (Nd-Fe-B) powders on rubberwood were characterized by vibrating sample magnetometry (VSM), magnetic moment measurements, and attraction tests with an iron-core solenoid. The Nd-Fe-B powders were recycled from electronic wastes by the ball-milling technique. Varying the milling time from 20 to 300 min, the magnetic squareness and the coercive field of the Nd-Fe-B powders were at the minimum when the powders were milled for 130 min. It followed that the coercive field of the magnetic wood composites was increased with the milling time increasing from 130 to 300 min. For the magnetic wood composites using Nd-Fe-B obtained from the same milling time, the magnetic squareness and the coercive field were rather insensitive to the variation of Nd-Fe-B concentration in coating lacquer from 0.43 to 1.00 g/cm3. By contrast, the magnetization and magnetic moment were increased with the Nd-Fe-B concentration increasing. Furthermore, the electrical current in the solenoid required for the attraction of the magnetic wood composites was exponentially reduced with the increase in the amount of Nd-Fe-B used in the coating.
Influence of stacking fault energy on defect structures and microhardness of Cu and Cu alloys.
Tao, Jing-Mei; Li, Dai; Li, Cai-Ju; Zhu, Xin-Kun
2011-12-01
Nano-structured Cu, Cu-10 wt%Zn and Cu-2 wt%Al with stacking fault energies (SFE) of 78, 35 and 37 mJ/m2, respectively, were preprared through high energy ball milling. X-ray diffraction and Vickers microharness test were used to investigate the microstructure and microhardness of all the samples after ball milling. X-ray diffraction measurements indicate that lower SFEs lead both to decrease in grain size and increase in microstrain, dislocation and twin densities for Cu-10 wt%Zn and Cu-2 wt%Al after 5 h of ball milling. The microhardnesses of Cu-10 wt%Zn and Cu-2 wt%Al reach to nearly the same values of 2.5 GPa after 5 h of ball milling, which is higher than that of Cu of 2.0 GPa. Two factors are considered to contribute to the finer grian size and higher microhardness of Cu-10 wt%Zn and Cu-2 wt%Al: (1) the effect of solid solution strengthening, which result in the interaction of solute atoms with screw dislocations; (2) the introduction of deformation twins during ball milling process by the decreasing of SFE, which results in the grain refinement.
Is Oral Health of the Sugar Mill Workers Being Compromised?
Pandita, Venisha; Patthi, Basavaraj; Singla, Ashish; Jain, Swati; Kundu, Hansa; Malhi, Ravneet; Vashishtha, Vaibhav
2015-01-01
Introduction Occupational environment has an immense influence on the general as well as oral health. The specific exposure to sugar and its byproducts might influence the dental health of sugar mill workers. Aim and Objectives The present study was conducted to assess and compare the oral health status of production line workers and administration staff working in the sugar mills of Western Uttar Pradesh. Materials and Methods A cross-sectional study was conducted in four Government aided and four Private sugar mills of West Uttar Pradesh, India among the production line workers and administration staff. Multistage random sampling methodology was employed to select total of 600 sugar mill factory workers (449 production line workers and 151 administration staff). The oral health status of the study subjects was assessed using the modified WHO Oral health survey Performa 1997. Statistical Analysis SPSS 19 Version was used for statistical analysis. Mean, Standard Deviation and proportions were calculated for each clinical parameter. Student t-test and Chi-square analysis was done to analyse inter group comparison. Results Mean DMFT for production and non production line workers was 7.67± 2.99 and 0.15 ± 1.34 (p= 0.001) respectively. 80.17% of production line workers had maximum CPI score 2 in contrast to 63.57% of administration staff (p=0.324). Conclusion The dental health was found to be debilitated among the production line workers of Sugar mill as compared to the Administrative staff. It is therefore recommended to raise the awareness among the sugar mill workers regarding the same. PMID:26266207
Design of a Computerised Flight Mill Device to Measure the Flight Potential of Different Insects.
Martí-Campoy, Antonio; Ávalos, Juan Antonio; Soto, Antonia; Rodríguez-Ballester, Francisco; Martínez-Blay, Victoria; Malumbres, Manuel Pérez
2016-04-07
Several insect species pose a serious threat to different plant species, sometimes becoming a pest that produces significant damage to the landscape, biodiversity, and/or the economy. This is the case of Rhynchophorus ferrugineus Olivier (Coleoptera: Dryophthoridae), Semanotus laurasii Lucas (Coleoptera: Cerambycidae), and Monochamus galloprovincialis Olivier (Coleoptera: Cerambycidae), which have become serious threats to ornamental and productive trees all over the world such as palm trees, cypresses, and pines. Knowledge about their flight potential is very important for designing and applying measures targeted to reduce the negative effects from these pests. Studying the flight capability and behaviour of some insects is difficult due to their small size and the large area wherein they can fly, so we wondered how we could obtain information about their flight capabilities in a controlled environment. The answer came with the design of flight mills. Relevant data about the flight potential of these insects may be recorded and analysed by means of a flight mill. Once an insect is attached to the flight mill, it is able to fly in a circular direction without hitting walls or objects. By adding sensors to the flight mill, it is possible to record the number of revolutions and flight time. This paper presents a full description of a computer monitored flight mill. The description covers both the mechanical and the electronic parts in detail. The mill was designed to easily adapt to the anatomy of different insects and was successfully tested with individuals from three species R. ferrugineus, S. laurasii, and M. galloprovincialis.
Design of a Computerised Flight Mill Device to Measure the Flight Potential of Different Insects
Martí-Campoy, Antonio; Ávalos, Juan Antonio; Soto, Antonia; Rodríguez-Ballester, Francisco; Martínez-Blay, Victoria; Malumbres, Manuel Pérez
2016-01-01
Several insect species pose a serious threat to different plant species, sometimes becoming a pest that produces significant damage to the landscape, biodiversity, and/or the economy. This is the case of Rhynchophorus ferrugineus Olivier (Coleoptera: Dryophthoridae), Semanotus laurasii Lucas (Coleoptera: Cerambycidae), and Monochamus galloprovincialis Olivier (Coleoptera: Cerambycidae), which have become serious threats to ornamental and productive trees all over the world such as palm trees, cypresses, and pines. Knowledge about their flight potential is very important for designing and applying measures targeted to reduce the negative effects from these pests. Studying the flight capability and behaviour of some insects is difficult due to their small size and the large area wherein they can fly, so we wondered how we could obtain information about their flight capabilities in a controlled environment. The answer came with the design of flight mills. Relevant data about the flight potential of these insects may be recorded and analysed by means of a flight mill. Once an insect is attached to the flight mill, it is able to fly in a circular direction without hitting walls or objects. By adding sensors to the flight mill, it is possible to record the number of revolutions and flight time. This paper presents a full description of a computer monitored flight mill. The description covers both the mechanical and the electronic parts in detail. The mill was designed to easily adapt to the anatomy of different insects and was successfully tested with individuals from three species R. ferrugineus, S. laurasii, and M. galloprovincialis. PMID:27070600
Development and comparison of projection and image space 3D nodule insertion techniques
NASA Astrophysics Data System (ADS)
Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Samei, Ehsan
2016-04-01
This study aimed to develop and compare two methods of inserting computerized virtual lesions into CT datasets. 24 physical (synthetic) nodules of three sizes and four morphologies were inserted into an anthropomorphic chest phantom (LUNGMAN, KYOTO KAGAKU). The phantom was scanned (Somatom Definition Flash, Siemens Healthcare) with and without nodules present, and images were reconstructed with filtered back projection and iterative reconstruction (SAFIRE) at 0.6 mm slice thickness using a standard thoracic CT protocol at multiple dose settings. Virtual 3D CAD models based on the physical nodules were virtually inserted (accounting for the system MTF) into the nodule-free CT data using two techniques. These techniques include projection-based and image-based insertion. Nodule volumes were estimated using a commercial segmentation tool (iNtuition, TeraRecon, Inc.). Differences were tested using paired t-tests and R2 goodness of fit between the virtually and physically inserted nodules. Both insertion techniques resulted in nodule volumes very similar to the real nodules (<3% difference) and in most cases the differences were not statistically significant. Also, R2 values were all <0.97 for both insertion techniques. These data imply that these techniques can confidently be used as a means of inserting virtual nodules in CT datasets. These techniques can be instrumental in building hybrid CT datasets composed of patient images with virtually inserted nodules.
NASA Astrophysics Data System (ADS)
Kozawa, Takahiro; Murakami, Takeshi; Naito, Makio
2016-07-01
The Ni-doped lithium manganese oxide, LiNi0.5Mn1.5O4, has received much attention as a cathode active material in high-energy lithium-ion batteries (LIBs). This active material has two different spinel structures depending on the ordering state of the Ni and Mn ions. The ordered LiNi0.5Mn1.5O4 spinel has an inferior cathode performance than the disordered phase because of its poor electronic conductivity. However, the ordered LiNi0.5Mn1.5O4 spinel possesses the potential advantage of avoiding dissolution of the Mn ion, which is an issue for the disordered spinel. The improvement of cathode performance is important for future applications. Here, we report a unique approach to improve the cathode performance of the ordered LiNi0.5Mn1.5O4 spinel. The mechanical treatment using an attrition-type mill successfully inserted lattice strains into the ordered LiNi0.5Mn1.5O4 spinel structure without a phase transformation to the disordered phase. The insertion of lattice strains by mechanical stresses provided an increased discharge capacity and a decreased charge transfer resistance. This limited crystal structure modification improved the cathode performance. The present work has the potential for application of the mechanically treated ordered LiNi0.5Mn1.5O4 spinel as a cathode for high-energy LIBs.
Long lifetime hollow cathodes for 30-cm mercury ion thrusters
NASA Technical Reports Server (NTRS)
Mirtich, M. J.; Kerslake, W. R.
1976-01-01
An experimental investigation of hollow cathodes for 30-cm Hg bombardment thrusters was carried out. Both main and neutralizer cathode configurations were tested with both rolled foil inserts coated with low work function material and impregnated porous tungsten inserts. Temperature measurements of an impregnated insert at various positions in the cathode were made. These, along with the cathode thermal profile are presented. A theory for rolled foil and impregnated insert operation and lifetime in hollow cathodes is developed. Several endurance tests, as long as 18,000 hours at emission currents of up to 12 amps were attained with no degradation in performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raj K. Rajamani; Jose Angel Delgadillo
A research team from the University of Utah is working to make inroads into saving energy in these SAG mills. In 2003, Industries of the Future Program of the Department of Energy tasked the University of Utah team to build a partnership between the University and the mining industry for the specific purpose of reducing energy consumption in SAG mills. A partnership was formed with Cortez Gold Mines, Kennecott Utah Copper Corporation, Process Engineering Resources Inc. and Outokumpu Technology. In the current project, Cortez Gold Mines played a key role in facilitating the 26-ft SAG mill at Cortez as amore » test mill for this study. According to plant personnel, there were a number of unscheduled shut downs to repair broken liners and the mill throughput fluctuated depending on ore type. The University team had two softwares, Millsoft and FlowMod to tackle the problem. Millsoft is capable of simulating the motion of charge in the mill. FlowMod calculates the slurry flow through the grate and pulp lifters. Based on this data the two models were fine-tuned to fit the Cortez SAG will. In the summer of 2004 a new design of shell lifters were presented to Cortez and in September 2004 these lifters were installed in the SAG mill. By December 2004 Cortez Mines realized that the SAG mill is drawing approximately 236-kW less power than before while maintaining the same level of production. In the first month there was extreme cycling and operators had to learn more. Now the power consumption is 0.3-1.3 kWh/ton lower than before. The actual SAG mill power draw is 230-370 kW lower. Mill runs 1 rpm lesser in speed on the average. The recirculation to the cone crusher is reduced by 1-10%, which means more efficient grinding of critical size material is taking place in the mill. All of the savings have resulted in reduction of operating cost be about $0.023-$0.048/ ton. After completing the shell lifter design, the pulp lifter design was taken up. Through a series of mill surveys and model calculations it was figured that the radial pulp lifter installed on the mill had less than optimum discharge capacity. A number of alternative designs were evaluated. The final choice was the Turbo Pulp Lifter for which Outukumpu Technology, Centennial, Colorado had filed a patent. After installation of the pulp lifter a 22% increase in throughput rate from 344 stph to 421 stph was realized. A 35% decrease in the SAG mill power draw from 3,908 HP to 2,526 HP (2,915 kW to 1,884 kW) was recorded. This equates to a 47% decrease in SAG unit energy consumption from 8.98 kWh/ton to 4.74 kWh/ton. A 11% decrease in SAG mill speed was observed indicating optimized ball strikes. Also, the ball chip generation from the SAG mill was reduced considerably. Further more, a 7% decrease in ball mill power draw from 4,843 HP to 4,491 HP (3,613 kW to 3,350 kW) was observed. This equates to a 24% decrease in ball mill unit energy consumption from 11.13 kWh/ton to 8.43 kWh/ton.« less
NASA Technical Reports Server (NTRS)
Soderman, Paul T.; Olsen, Larry E.
1990-01-01
An engineering feasibility study was made of aeroacoustic inserts designed for large-scale acoustic research on aircraft models in the 80 by 120 foot Wind Tunnel at NASA Ames Research Center. The advantages and disadvantages of likely designs were analyzed. Results indicate that the required maximum airspeed leads to the design of a particular insert. Using goals of 200, 150, and 100 knots airspeed, the analysis indicated a 30 x 60 ft open-jet test section, a 40 x 80 ft open jet test section, and a 70 x 100 ft closed test section with enhanced wall lining, respectively. The open-jet inserts would be composed of a nozzle, collector, diffuser, and acoutic wedges incorporated in the existing 80 x 120 test section. The closed test section would be composed of approximately 5 ft acoustic wedges covered by a porous plate attached to the test section walls of the existing 80 x 120. All designs would require a double row of acoustic vanes between the test section and fan drive to attenuate fan noise and, in the case of the open-jet designs, to control flow separation at the diffuser downstream end. The inserts would allow virtually anechoic acoustic studies of large helicopter models, jets, and V/STOL aircraft models in simulated flight. Model scale studies would be necessary to optimize the aerodynamic and acoustic performance of any of the designs. In all designs studied, the existing structure would have to be reinforced. Successful development of acoustically transparent walls, though not strictly necessary to the project, would lead to a porous-wall test section that could be substituted for any of the open-jet designs, and thereby eliminate many aerodynamic and acoustic problems characteristic of open-jet shear layers. The larger size of the facility would make installation and removal of the insert components difficult. Consequently, scheduling of the existing 80 x 120 aerodynamic test section and scheduling of the open-jet test section would likely be made on an annual or longer basis. The enhanced wall-lining insert would likely be permanent. Although the modifications are technically feasible, the economic practicality of the project was not evaluated.
Testing Of Choiced Ceramics Cutting Tools At Irregular Interrupted Cut
NASA Astrophysics Data System (ADS)
Kyncl, Ladislav; Malotová, Šárka; Nováček, Pavel; Nicielnik, Henryk; Šoková, Dagmar; Hemžský, Pavel; Pitela, David; Holubjak, Jozef
2015-12-01
This article discusses the test of removable ceramic cutting inserts during machining irregular interrupted cut. Tests were performed on a lathe, with the preparation which simulated us the interrupted cut. By changing the number of plates mounted in a preparation it simulate us a regular or irregular interrupted cut. When with four plates it was regular interrupted cut, the remaining three variants were already irregular cut. It was examined whether it will have the irregular interrupted cutting effect on the insert and possibly how it will change life of inserts during irregular interrupted cut (variable delay between shocks).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baum, A.J.
1995-05-01
The objective of this program was to perform qualification tests of industrial heats of thermally treated alloy 690 steam generator tubing under heat transfer conditions. Primary emphasis was focused on testing of alternate tube to tubesheet expansion processes. In addition, a background report was written to document the evolution of the alloy 690 process specification and the supporting qualification testing. While the testing was able to produce some localized corrosion of alloy 690 in the tube to tubesheet joint transition regions under highly alkaline conditions, the corrosion rates were between two and three orders of magnitude lower than the comparablemore » rates in mill annealed alloy 600 tubing. The corrosion morphology was a combination of intergranular and general corrosion, rather than the stress corrosion cracking typically found in mill annealed alloy 600 tubing.« less
NASA Astrophysics Data System (ADS)
Genereux, Louis-Alexandre
The main goal of this work is to evaluate the impact of milling operations on the integrity of unidirectional carbon/epoxy laminate. Milling, often used for finishing composite structures, cause some damage in the form of craters, cracks and thermal damage to the matrix. Here, two approaches are used to qualify and quantify the amount of damage. First, two nondestructive testing methods, namely immersion ultrasonic inspection and pulsed thermography, are evaluated on samples with artificial defects. These techniques are then used on machined samples with realistic machining damages. Only ultrasounds allowed the detection and quantification of the machining damages, but only if the damages are at the surface of the laminate. The depth of damage depends primarily on the fiber orientation of the first ply with respect to the cutting direction. The ultrasonic inspections are also accompanied by scanning electron microscope observations. The second approach is to check whether the presence of the machining damage will affect the mechanical properties of the laminate. To do this, static tensile tests are performed on samples prepared by three different methods, namely, by abrasive diamond saw, by saw cut followed by sanding and finally by milling. The results show that the damages caused by the milling operation are not important enough to affect the ultimate stress and elastic modulus. Despite this, it would be interesting, for future works, to investigate this aspect in fatigue rather than with static tests. The presence of damages on the edge might promote delamination during cyclic loads.
Degidi, Marco; Daprile, Giuseppe; Piattelli, Adriano
The aims of this study were to evaluate the ability of a stepped osteotomy to improve dental implant primary stability in low-density bone sites and to investigate possible correlations between primary stability parameters. The study was performed on fresh humid bovine bone classified as type III. The test group consisted of 30 Astra Tech EV implants inserted following the protocol provided by the manufacturer. The first control group consisted of 30 Astra Tech EV implants inserted in sites without the underpreparation of the apical portion. The second control group consisted of 30 Astra Tech TX implants inserted following the protocol provided by the manufacturer. Implant insertion was performed at the predetermined 30 rpm. The insertion torque data were recorded and exported as a curve; using a trapezoidal integration technique, the area underlying the curve was calculated: this area represents the variable torque work (VTW). Peak insertion torque (pIT) and resonance frequency analysis (RFA) were also recorded. A Mann-Whitney test showed that the mean VTW was significantly higher in the test group compared with the first control and second control groups; furthermore, statistical analysis showed that pIT also was significantly higher in the test group compared with the first and second control groups. Analyzing RFA values, only the difference between the test group and second control group showed statistical significance. Pearson correlation analysis showed a very strong positive correlation between pIT and VTW values in all groups; furthermore, it showed a positive correlation between pIT and RFA values and between VTW and RFA values only in the test group. Within the limitations of an in vitro study, the results show that stepped osteotomy can be a viable method to improve implant primary stability in low-density bone sites, and that, when a traditional osteotomy method is performed, RFA presents no correlation with pIT and VTW.
Mesophilic co-digestion of palm oil mill effluent and empty fruit bunches.
Kim, Sang-Hyoun; Choi, Seon-Mi; Ju, Hyun-Jun; Jung, Jin-Young
2013-01-01
The palm oil mill industry generates palm oil mill effluent (POME) and empty fruit bunches (EFB) as by-products. This study reports the mesophilic co-digestion of POME with EFB. The biochemical methane potential (BMP) of POME and EFB was 0.397 L CH4/g volatile solids (VS) and 0.264 L CH4/g VS, respectively. In a series of batch tests at various EFB to POME ratios, the maximum methane production rate was achieved at an EFB:POME ratio of 0.25-0.31:1. Performance data from lab-scale digesters confirmed the positive synergism by the addition of EFB to POME, which was attributed to the balanced chemical composition, for example the chemical oxygen demand (COD) to total Kjeldahl nitrogen (TKN) ratio. The EFB addition enhanced the acceptable organic loading rate, methane production, COD removal, and microbial activity. The mesophilic co-digestion of POME and EFB promises to be a viable recycling method to alleviate pollution problems and recover renewable energy in the palm oil mill industry.
NASA Astrophysics Data System (ADS)
Mohan, S. Mariraj
2017-12-01
In this study, it was aimed for effective utilization of paper mill sludge through vermicomposting by varying seed proportion with sp. Eisenia fetida. Nine plastic trays were used for the experimental work including control. Different seed proportions of cow dung and cattle dung were tested. The multiplication of earthworms in terms of number was counted at the end of vermicomposting. The N, K, Ca, Na values of the manure in each vermibin were estimated before and after vermicomposting. In this study, it was concluded that tray A2 which has combination of 75% Cow dung (CD) and 25% Paper Mill Sludge (PMS) provided better nitrogen synthesis and lowering C/N ratio, whereas tray A4 (25%CD + 75% PMS) yielded better Calcium recovery. Both the seed materials were found to be suitable for Potassium recovery. From this study, it was inferred that vermicomposting of paper mill sludge with sp. Eisenia fetida along with seed materials can also solve the problem of disposal of this sludge.
Characteristics of ZrC/Ni-UDD coatings for a tungsten carbide cutting tool
NASA Astrophysics Data System (ADS)
Chayeuski, V. V.; Zhylinski, V. V.; Rudak, P. V.; Rusalsky, D. P.; Višniakov, N.; Černašėjus, O.
2018-07-01
This work deals with the features of the structure of combined ZrC/Ni-ultradisperse diamonds (UDD) coating synthesized by electroplating and cathode arc evaporation physical vapor deposition (CAE-PVD) techniques on the tungsten carbide WC - 2 wt% Co on cutting inserts to improve tool life. The microstructure, phase composition, and micro-scratch test analysis of the ZrC/Ni-UDD coating were studied. The ZrC/Ni-UDD coating consists of separate phases of zirconium carbide ZrC, α-Ni, and Ni-UDD phase. The surface morphology of the coating shows a pattern with pits, pores, and particles. Separated nanodiamond particles are present in the pores of the combined coating. Therefore, the structure of the bottom layer of Ni-UDD affects the morphology of the surface of the ZrC/Ni-UDD coating. The obtained value of the critical loads on the scratch track of the coating in 26 N proves a sufficiently high value of the adhesion strength of the intermediate Ni-UDD-layer with hard alloy of WC-Co substrate. Due to their unique structure ZrC/Ni-UDD-coatings can be used to increase the durability period of a wood-cutting milling tool for cutting chipboard by CNC machines.
1964-06-19
XV-5A airplane installed in 40x80ft Subsonic Wind Tunnel at NASA Ames Research Center with Tom Mills. The propulsive lift system was tested to determine power-on performance characteristics in preparation for flight tests.
1964-06-19
XV-5A airplane installed in 40x80ft Subsonic Wind Tunnel at NASA Ames Research Center with Tom Mills. The propulsive lift system was tested to determine power-on performance characteristics in preparation for flight tests.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nydal, R.; Brenkert, A.L.; Boden, T.A.
1998-03-01
In the 1960s, thermonuclear bomb tests released significant pulses of radioactive carbon-14 ({sup 14}C) into the atmosphere. These major perturbations allowed scientists to study the dynamics of the global carbon cycle by calculating rates of isotope exchange between the atmosphere and ocean waters. A total of 950 ocean surface water observations were made from 1965 through 1994. The measurements were taken at 30 stations in the Atlantic Ocean, 14 stations in the Indian Ocean, and 38 stations in the Pacific Ocean. Thirty-two of the 950 samples were taken in the Atlantic Ocean during the R/V Andenes research cruise. {sup 14}Cmore » was measured in 871 of the 950 samples, and those measurements have been corrected ({Delta}{sup 14}C) for isotopic fractionation and radioactive decay. The {Delta}{sup 14}C values range between {minus}113.3 and 280.9 per mille and have a mean value of 101.3 per mille. The highest yearly mean (146.5 per mille) was calculated for 1969, the lowest yearly mean value was calculated for 1990 (67.9 per mille) illustrating a decrease over time. This decrease was to be expected as a result of the ban on atmospheric thermonuclear tests and the slow mixing of the ocean surface waters with the deeper layers.« less
Diederich, Emily; Thomas, Laura; Mahnken, Jonathan; Lineberry, Matthew
2018-06-01
Within simulation-based mastery learning (SBML) courses, there is inconsistent inclusion of learner pretesting, which requires considerable resources and is contrary to popular instructional frameworks. However, it may have several benefits, including its direct benefit as a form of deliberate practice and its facilitation of more learner-specific subsequent deliberate practice. We consider an unexplored potential benefit of pretesting: its ability to predict variable long-term learner performance. Twenty-seven residents completed an SBML course in central line insertion. Residents were tested on simulated central line insertion precourse, immediately postcourse, and after between 64 and 82 weeks. We analyzed pretest scores' prediction of delayed test scores, above and beyond prediction by program year, line insertion experiences in the interim, and immediate posttest scores. Pretest scores related strongly to delayed test scores (r = 0.59, P = 0.01; disattenuated ρ = 0.75). The number of independent central lines inserted also related to year-delayed test scores (r = 0.44, P = 0.02); other predictors did not discernibly relate. In a regression model jointly predicting delayed test scores, pretest was a significant predictor (β = 0.487, P = 0.011); number of independent insertions was not (β = 0.234, P = 0.198). This study suggests that pretests can play a major role in predicting learner variance in learning gains from SBML courses, thus facilitating more targeted refresher training. It also exposes a risk in SBML courses that learners who meet immediate mastery standards may be incorrectly assumed to have equal long-term learning gains.
Time-elapsed screw insertion with microCT imaging.
Ryan, M K; Mohtar, A A; Cleek, T M; Reynolds, K J
2016-01-25
Time-elapsed analysis of bone is an innovative technique that uses sequential image data to analyze bone mechanics under a given loading regime. This paper presents the development of a novel device capable of performing step-wise screw insertion into excised bone specimens, within the microCT environment, whilst simultaneously recording insertion torque, compression under the screw head and rotation angle. The system is computer controlled and screw insertion is performed in incremental steps of insertion torque. A series of screw insertion tests to failure were performed (n=21) to establish a relationship between the torque at head contact and stripping torque (R(2)=0.89). The test-device was then used to perform step-wise screw insertion, stopping at intervals of 20%, 40%, 60% and 80% between screw head contact and screw stripping. Image data-sets were acquired at each of these time-points as well as at head contact and post-failure. Examination of the image data revealed the trabecular deformation as a result of increased insertion torque was restricted to within 1mm of the outer diameter of the screw thread. Minimal deformation occurred prior to the step between the 80% time-point and post-failure. The device presented has allowed, for the first time, visualization of the micro-mechanical response in the peri-implant bone with increased tightening torque. Further testing on more samples is expected to increase our understanding of the effects of increased tightening torque at the micro-structural level, and the failure mechanisms of trabeculae. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Durieux, A.; Martin, B.; Laubier, D.
2017-11-01
DECLIC, a Facility dedicated to the study of transparent media under microgravity, will be used in an ISS EXPRESS Rack. This paper focuses on the EXL which contains two optical boxes disposed on two opposite sides of the cavity where the Inserts to be studied shall be locked. At the moment, three types of inserts are planned to be accommodated in the EXL. Various optical diagnostics are available by configuring the EXL (sources, sensors, mechanisms). After the presentation of the EXL design, this article deals with some manufacturing and testing aspects, such as the use of COTS (cameras). Specific OGSE have been developed in order to simulate the optical interfaces and the propagation of beams in the inserts. Three models of the EXL have been integrated and fully tested, including the Flight Model. The sequence of tests, the performances measured, and then some images of the experiments performed with the inserts will be presented.
Relationship between footwear comfort of shoe inserts and anthropometric and sensory factors.
Mündermann, A; Stefanyshyn, D J; Nigg, B M
2001-11-01
The purposes of this study were (a) to determine lower extremity anthropometric and sensory factors that are related to differences in comfort perception of shoe inserts with varying shape and material and (b) to investigate whether shoe inserts that improve comfort decrease injury frequency in a military population. 206 military personnel volunteered for this study. The shoe inserts varied in arch and heel cup shape, hardness, and elasticity in the heel and forefoot regions. A no insert condition was included as the control condition. Measured subject characteristics included foot shape, foot and leg alignment, and tactile and vibration sensitivity of the plantar surface of the foot. Footwear comfort was assessed using a visual analog scale. Injury frequency was evaluated with a questionnaire. The statistical analyses included Student's t-tests for repeated measures, ANOVA (within subjects), MANOVA (within insert combinations), and chi-square tests. The average comfort ratings for all shoe inserts were significantly higher than the average comfort rating for the control condition. The incidence of stress fractures and pain at different locations was reduced by 1.5-13.4% for the insert compared with the control group. Foot arch height, foot and leg alignment, and foot sensitivity were significantly related to differences in comfort ratings for the hard/soft, the viscous/elastic, and the high arch/low arch insert combinations. Shoe inserts of different shape and material that are comfortable are able to decrease injury frequency. The results of this study showed that subject specific characteristics influence comfort perception of shoe inserts.
Effect of shoe inserts on kinematics, center of pressure, and leg joint moments during running.
Nigg, Benno M; Stergiou, Pro; Cole, Gerald; Stefanyshyn, Darren; Mündermann, Anne; Humble, Neil
2003-02-01
The purposes of this project were to assess the effect of four different shoe inserts on the path of the center of pressure (COP), to quantify the effect of these inserts on selected knee joint moments during running, and to assess the potential of COP data to predict the effects of inserts/orthotics on knee joint moments. Kinematics for the lower extremities, resultant ankle and knee joint moments, and the path of the COP were collected from the right foot of 15 male subjects while running heel-toe with five different shoe inserts (full or half with 4.5-mm postings). Individual movement changes with respect to the neutral insert condition were typically small and not systematic. Significant changes for the path of the COP were registered only for the full lateral insert condition with an average shift toward the lateral side. The mediolateral shift of the COP was not consistent for the full medial and the two half-shoe inserts. The subject-specific reactions to the inserts' intervention in the corresponding knee joint moments were typically not consistent. Compared with the neutral insert condition, subjects showed increases or decreases of the knee joint moments. The correlation between the individual COP shifts and the resultant knee joint moment was generally small. The results of this study showed that subject-specific reactions to the tested inserts were often not as expected. Additionally, reactions were not consistent between the subjects. This result suggests that the prescription of inserts and/or orthotics is a difficult task and that methods must be developed to test and assess these effects. Such methods, however, are not currently available.
Nguyen, Yann; Bernardeschi, Daniele; Kazmitcheff, Guillaume; Miroir, Mathieu; Vauchel, Thomas; Ferrary, Evelyne; Sterkers, Olivier
2015-02-01
Loading otoprotective drug into cochlear implant might change its mechanical properties, thus compromising atraumatic insertion. This study evaluated the effect of incorporation of dexamethasone (DXM) in the silicone of cochlear implant arrays on insertion forces. Local administration of DXM with embedded array can potentially reduce inflammation and fibrosis after cochlear implantation procedure to improve hearing preservation and reduce long-term impedances. Four models of arrays have been tested: 0.5-mm distal diameter array (n = 5) used as a control, drug-free 0.4-mm distal diameter array (n = 5), 0.4-mm distal diameter array with 1% eluded DXM silicone (n = 5), and 0.4-mm distal diameter array with 10% eluded DXM silicone (n = 5). Via a motorized insertion bench, each array has been inserted into an artificial scala tympani model. The forces were recorded by a 6-axis force sensor. Each array was tested seven times for a total number of 140 insertions. During the first 10-mm insertion, no difference between the four models was observed. From 10- to 24-mm insertion, the 0.5-mm distal diameter array presented higher insertion forces than the drug-free 0.4-mm distal diameter arrays, with or without DXM. Friction forces for drug-free 0.4-mm distal diameter array and 0.4-mm distal diameter DXM eluded arrays were similar on all insertion lengths. Incorporation of DXM in silicone for cochlear implant design does not change electrode array insertion forces. It does not raise the risk of trauma during array insertion, making it suitable for long-term in situ administration to the cochlea.
Aflatoxin B1 levels in groundnut products from local markets in Zambia.
Njoroge, Samuel M C; Matumba, Limbikani; Kanenga, Kennedy; Siambi, Moses; Waliyar, Farid; Maruwo, Joseph; Machinjiri, Norah; Monyo, Emmanuel S
2017-05-01
In Zambia, groundnut products (milled groundnut powder, groundnut kernels) are mostly sold in under-regulated markets. Coupled with the lack of quality enforcement in such markets, consumers may be at risk to aflatoxin exposure. However, the level of aflatoxin contamination in these products is not known. Compared to groundnut kernels, milled groundnut powder obscures visual indicators of aflatoxin contamination in groundnuts such as moldiness, discoloration, insect damage or kernel damage. A survey was therefore conducted from 2012 to 2014, to estimate and compare aflatoxin levels in these products (n = 202), purchased from markets in important groundnut growing districts and in urban areas. Samples of whole groundnut kernels (n = 163) and milled groundnut powder (n = 39) were analysed for aflatoxin B 1 (AFB 1 ) by competitive enzyme-linked immunosorbent assay (cELISA). Results showed substantial AFB 1 contamination levels in both types of groundnut products with maximum AFB 1 levels of 11,100 μg/kg (groundnut kernels) and 3000 μg/kg (milled groundnut powder). However, paired t test analysis showed that AFB 1 contamination levels in milled groundnut powder were not always significantly higher (P > 0.05) than those in groundnut kernels. Even for products from the same vendor, AFB 1 levels were not consistently higher in milled groundnut powder than in whole groundnut kernels. This suggests that vendors do not systematically sort out whole groundnut kernels of visually poor quality for milling. However, the overall contamination levels of groundnut products with AFB 1 were found to be alarmingly high in all years and locations. Therefore, solutions are needed to reduce aflatoxin levels in such under-regulated markets.
Addeck, Amr; Croes, Kim; Van Langenhove, Kersten; Denison, Michael S.; Elhamalawy, Ahmed; Elskens, Marc; Baeyens, Willy
2015-01-01
The ceramic toximeter as a passive sampler in combination with the CALUX bioassay was utilized as a time-integrated pollution-assessment technique for dioxin-like PCDD/Fs in wastewaters. Toximeters filled with XCARB and enclosed in stainless steel cages were submerged in wastewater of Belbeis drainage-canal and EMAK paper-mill, located in Egypt, for 28 days. Two samplers were removed every week from each site. Extracts from toximeters, from bottom-sediments, and from paper-mill sludge were analyzed by the CALUX. Results showed a regular increase in the amounts of PCDD/Fs trapped by the toximeters as sampling time increased. Time-weighted average concentrations (TWA) of PCDD/Fs in the wastewaters of the drainage-canal and paper-mill were 231 (214-281) and 26 (24.1-32.6) pg-BEQ L-1, respectively. Compared to literature data, this means a high pollution level for the drainage-canal water, while the pollution level in the paper-mill wastewater is similar to that reported for other paper mills. The PCDD/Fs levels in the drainage-canal bottom-sediments and in the paper-mill sludge were 8.3 and 14.6 pg-BEQ g-1 dry-weight, at the lower end of internationally reported values in similar compartments. The sampling rate of the tested toximeters for dissolved PCDD/Fs was about 3.6 mL d-1. Sediment/water partitioning coefficient log Kd of PCDD/Fs in the drainage-canal and the paper-mill was 1.42 and 2.70 respectively. The organic-carbon normalized partition coefficient log Koc was 4.17 and 3.19 respectively, and is lower than the reported values for other sites. PMID:24075528
Addeck, Amr; Croes, Kim; Van Langenhove, Kersten; Denison, Michael S; Elhamalawy, Ahmed; Elskens, Marc; Baeyens, Willy
2014-01-01
The ceramic toximeter as a passive sampler in combination with the CALUX bioassay was utilized as a time-integrated pollution-assessment technique for dioxin-like PCDD/Fs in wastewaters. Toximeters filled with XCARB and enclosed in stainless steel cages were submerged in wastewater of Belbeis drainage-canal and EMAK paper-mill, located in Egypt, for 28 days. Two samplers were removed every week from each site. Extracts from toximeters, from bottom-sediments, and from paper-mill sludge were analyzed by the CALUX. Results showed a regular increase in the amounts of PCDD/Fs trapped by the toximeters as sampling time increased. Time-weighted average concentrations (TWA) of PCDD/Fs in the wastewaters of the drainage-canal and paper-mill were 231 (214-281) and 26 (24.1-32.6) pg-BEQL(-1), respectively. Compared to literature data, this means a high pollution level for the drainage-canal water, while the pollution level in the paper-mill wastewater is similar to that reported for other paper mills. The PCDD/Fs levels in the drainage-canal bottom-sediments and in the paper-mill sludge were 8.3 and 14.6 pg-BEQg(-1) dry-weight, at the lower end of internationally reported values in similar compartments. The sampling rate of the tested toximeters for dissolved PCDD/Fs was about 3.6 mL d(-1). Sediment/water partitioning coefficient logKd of PCDD/Fs in the drainage-canal and the paper-mill was 1.42 and 2.70 respectively. The organic-carbon normalized partition coefficient logKoc was 4.17 and 3.19 respectively, and is lower than the reported values for other sites. Copyright © 2013 Elsevier Ltd. All rights reserved.
Lung Function before and after a Large Chlorine Gas Release in Graniteville, South Carolina
Karmaus, Wilfried J. J.; Mohr, Lawrence C.; Cai, Bo; Balte, Pallavi; Gibson, James J.; Ownby, Dennis; Lawson, Andrew B.; Vena, John E.; Svendsen, Erik R.
2016-01-01
Rationale: On January 6, 2005 a train derailment led to an estimated 54,915-kg release of chlorine at a local textile mill in Graniteville, South Carolina. Objectives: We used the employee health spirometry records of the textile to identify enduring effects of chlorine gas exposure resulting from the incident on the lung function of workers employed at the textile mill. Methods: Spirometry records from 1,807 mill workers (7,332 observations) were used from 4 years before and 18 months after the disaster. Longitudinal analysis using marginal regression models produced annual population mean estimates for FEV1, FVC, and FEV1/FVC ratio. Covariate adjustment was made for sex, age, smoking, height, season tested, technician, obesity, season × year interactions, and smoker × year interactions. The increased prevalence of mill workers having accelerated FEV1 decline was also evaluated after the chlorine spill. Measurements and Main Results: In the year of the accident, we observed a significant reduction in mean FEV1 (–4.2% predicted; P = 0.019) when compared with the year before the incident. In the second year, partial recovery in the mean FVC % predicted level was seen, but the cohort’s average FEV1/FVC ratio continued to decrease over time. Severe annual FEV1 decline was most prevalent in the year of the accident, and independent of mill worker smoking status. Conclusions: The Graniteville mill worker cohort revealed significant reductions in lung function immediately after the chlorine incident. Improvement was seen in the second year; but the proportion of mill workers experiencing accelerated FEV1 annual decline significantly increased in the 18 months after the chlorine incident. PMID:26695511
NASA Astrophysics Data System (ADS)
Nakamori, Kota; Suzuki, Yasuki; Ohya, Hiroyo; Takano, Toshiaki; Kawamura, Yohei; Nakata, Hiroyuki; Yamashita, Kozo
2017-04-01
It is known that lightning and precipitations of rain droplets generated from thunderclouds are a generator of global atmospheric electric circuit. In the fair weather, the atmospheric electric fields (AEF) are downward (positive), while they are upward (negative) during lightning and precipitations. However, the correlations between the AEF, and the cloud parameters such as cloud cover, weather phenomenon, have been not revealed quantitatively yet. In this study, we investigate the correlations between the AEF and the cloud parameters, weather phenomenon using a field mill, the 95 GHz-FALCON (FMCW Radar for Cloud Observations)-I and all-sky camera observations. In this study, we installed a Boltek field mill on the roof of our building in Chiba University, Japan, (Geographic coordinate: 35.63 degree N, 140.10 degree E, the sea level: 55 m) on the first June, 2016. The sampling time of the AEF is 0.5 s. On the other hand, the FALCON-I has observed the cloud parameters far from about 76 m of the field mill throughout 24 hours every day. The vertical cloud profiles and the Doppler velocity of cloud particles can be derived by the FALCON-I with high distance resolutions (48.8 m) (Takano et al., 2010). In addition, the images of the clouds and precipitations are recorded with 30-s sampling by an all-sky camera using a CCD camera on the same roof during 05:00-22:00 LT every day. The distance between the field mill and the all-sky camera is 3.75 m. During 08:30 UT - 10:30 UT, on 4 July, 2016, we found the variation of the AEF due to the approach of thundercloud. The variation consisted of two patterns. One was slow variation due to the movement of thunderclouds, and the other was rapid variation associated with lightning discharges. As for the movement of thunderclouds, the AEF increased when the anvil was located over the field mill, which was opposite direction of the previous studies. This change might be due to the positive charges in the upper anvil more than 14 km altitude. As for the rapid variations of the AEF, 12 peaks of the AEF coincided with the occurrence of the lightning within 37 km. Moreover, we developed the automatic procedure to estimate the cloud cover from cloud optical images using the RGB color values. We estimated the correlation between the cloud cover and the AEF during June - November, 2016. The AEF decreased with increasing the cloud cover. This trend may be caused by the dielectric polarization due to the insert of the dielectric clouds into the global condenser. The standard deviation of AEF was small when the cloud cover increased. In this session, we will show the variations in the AEF during usual precipitations and snowing.
Arcjet nozzle area ratio effects
NASA Technical Reports Server (NTRS)
Curran, Francis M.; Sarmiento, Charles J.; Birkner, Bjorn W.; Kwasny, James
1990-01-01
An experimental investigation was conducted to determine the effect of nozzle area ratio on the operating characteristics and performance of a low power dc arcjet thruster. Conical thoriated tungsten nozzle inserts were tested in a modular laboratory arcjet thruster run on hydrogen/nitrogen mixtures simulating the decomposition products of hydrazine. The converging and diverging sides of the inserts had half angles of 30 and 20 degrees, respectively, similar to a flight type unit currently under development. The length of the diverging side was varied to change the area ratio. The nozzle inserts were run over a wide range of specific power. Current, voltage, mass flow rate, and thrust were monitored to provide accurate comparisons between tests. While small differences in performance were observed between the two nozzle inserts, it was determined that for each nozzle insert, arcjet performance improved with increasing nozzle area ratio to the highest area ratio tested and that the losses become very pronounced for area ratios below 50. These trends are somewhat different than those obtained in previous experimental and analytical studies of low Re number nozzles. It appears that arcjet performance can be enhanced via area ratio optimization.
Arcjet Nozzle Area Ratio Effects
NASA Technical Reports Server (NTRS)
Curran, Francis M.; Sarmiento, Charles J.; Birkner, Bjorn W.; Kwasny, James
1990-01-01
An experimental investigation was conducted to determine the effect of nozzle area ratio on the operating characteristics and performance of a low power dc arcjet thruster. Conical thoriated tungsten nozzle inserts were tested in a modular laboratory arcjet thruster run on hydrogen/nitrogen mixtures simulating the decomposition products of hydrazine. The converging and diverging sides of the inserts had half angles of 30 and 20 degrees, respectively, similar to a flight type unit currently under development. The length of the diverging side was varied to change the area ratio. The nozzle inserts were run over a wide range of specific power. Current, voltage, mass flow rate, and thrust were monitored to provide accurate comparisons between tests. While small differences in performance were observed between the two nozzle inserts, it was determined that for each nozzle insert, arcjet performance improved with increasing nozzle area ratio to the highest area ratio tested and that the losses become very pronounced for area ratios below 50. These trends are somewhat different than those obtained in previous experimental and analytical studies of low Re number nozzles. It appears that arcjet performance can be enhanced via area ratio optimization.
Parrotta, Luigi; Campani, Tommaso; Casini, Silvia; Romi, Marco; Cai, Giampiero
2016-08-03
Disposal and reuse of olive-mill wastes are both an economic and environmental problem, especially in countries where the cultivation of olive trees is extensive. Microorganism-based bioaugmentation can be used to reduce the pollutant capacity of wastes. In this work, bioaugmentation was used to reduce the polyphenolic content of both liquid and solid wastes. After processing, bioaugmented wastes were tested on the root development of maize seeds and on photosynthesis-related molecules of tobacco plants. In maize, we found that bioaugmentation made olive-mill wastes harmless for seed germination. In tobacco, we analyzed the content of RuBisCO (ribulose-1,5-bisphosphate carboxylase oxygenase) and of the photosynthetic pigments lutein, chlorophylls, and β-carotene. Levels of RuBisCO were negatively affected by untreated wastewater but increased if plants were treated with bioaugmented wastewater. On the contrary, levels of RuBisCO increased in the case of plants treated with raw olive-mill solid waste. Pigment levels showed dissimilar behavior because their concentration increased if plants were irrigated with raw wastewater or treated with raw olive-mill solid waste. Treatment with bioaugmented wastes restored pigment content. Findings show that untreated wastes are potentially toxic at the commencement of treatment, but plants can eventually adapt after an initial stress period. Bioaugmented wastes do not induce immediate damages, and plants rapidly recover optimal levels of photosynthetic molecules.
Comparison of retention between maxillary milled and conventional denture bases: A clinical study.
AlHelal, Abdulaziz; AlRumaih, Hamad S; Kattadiyil, Mathew T; Baba, Nadim Z; Goodacre, Charles J
2017-02-01
Clinical studies comparing the retention values of milled denture bases with those of conventionally processed denture bases are lacking. The purpose of this clinical study was to compare the retention values of conventional heat-polymerized denture bases with those of digitally milled maxillary denture bases. Twenty individuals with completely edentulous maxillary arches participated in this study. Definitive polyvinyl siloxane impressions were scanned (iSeries; Dental Wings), and the standard tessellation language files were sent to Global Dental Science for the fabrication of a computer-aided design and computer-aided manufacturing (CAD-CAM) milled denture base (group MB) (AvaDent). The impression was then poured to obtain a definitive cast that was used to fabricate a heat-polymerized acrylic resin denture base resin (group HB). A custom-designed testing device was used to measure denture retention (N). Each denture base was subjected to a vertical pulling force by using an advanced digital force gauge 3 times at 10-minute intervals. The average retention of the 2 fabrication methods was compared using repeated ANOVA (α=.05). Significantly increased retention was observed for the milled denture bases compared with that of the conventional heat-polymerized denture bases (P<.001). The retention offered by milled complete denture bases from prepolymerized poly(methyl methacrylate) resin was significantly higher than that offered by conventional heat- polymerized denture bases. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Rana, Madhab Ch; Naskar, Somnath; Roy, Ramaprasad; Das, Dilip Kr; Das, Soumya
2018-01-01
Rice mill workers constitute a special group from the perspective of occupational health. Unprotected dust exposure among them adversely affects their respiratory health, which needs to be evaluated. Adequate evidence is still lacking in many parts of India including West Bengal. Burdwan is one of the main rice-producing districts in the state with abundant rice mills. The aim of the study was to find out the prevalence and pattern of respiratory morbidity and associated background characteristics of rice mill workers. A descriptive cross-sectional study was conducted at Burdwan municipality area during July-December 2016. Considering 44.2% prevalence, 95% confidence interval, 15% allowable error, 10% non-response, a sample of 252 directly engaged rice mill workers were selected through multistage random sampling. With prior consent, the subjects were interviewed, clinically examined, and underwent spirometry; relevant records were also reviewed using a pre-designed schedule. Any abnormal spirometry finding was considered as respiratory morbidity. Ethical approval was obtained from institutional ethics committee. Data were analyzed using SPSS version 20. Chi-square test and multiple logistic regression were applied. Prevalence of respiratory morbidity was 40.73% with obstructive and restrictive respiratory morbidity being 24.60% and 16.13%, respectively. Non-use of any protective measure, duration (years) of working in rice mill and average daily working hours were significant predictors of respiratory morbidity. Respiratory morbidity is quite high in the area. Proper health education and provision of personal protective equipments need to be provided.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Grain Milled Rice, Medium Grain Milled Rice, Short Grain Milled Rice, and Mixed Milled Rice. (See also Â... Milled Rice Principles Governing Application of Standards § 868.310 Grades and grade requirements for the classes Long Grain Milled Rice, Medium Grain Milled Rice, Short Grain Milled Rice, and Mixed Milled Rice...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Grain Milled Rice, Medium Grain Milled Rice, Short Grain Milled Rice, and Mixed Milled Rice. (See also Â... Milled Rice Principles Governing Application of Standards § 868.310 Grades and grade requirements for the classes Long Grain Milled Rice, Medium Grain Milled Rice, Short Grain Milled Rice, and Mixed Milled Rice...
NASA Astrophysics Data System (ADS)
Dotsenko, V. V.; Sahu, A.; Chonigman, B.; Tang, J.; Lehmann, A. E.; Gupta, V.; Talalevskii, A.; Ruotolo, S.; Sarwana, S.; Webber, R. J.; Gupta, D.
2017-02-01
Research and development of cryogenic application-specific integrated circuits (ASICs), such as high-frequency (tens of GHz) semiconductor and superconductor mixed-signal circuits and large-scale (>10,000 Josephson Junctions) superconductor digital circuits, have long been hindered by the absence of specialized cryogenic test apparatus. During their iterative development phase, most ASICs require many additional input-output lines for applying independent bias controls, injecting test signals, and monitoring outputs of different sub-circuits. We are developing a full suite of modular test apparatus based on cryocoolers that do not consume liquid helium, and support extensive electrical interfaces to standard and custom test equipment. Our design separates the cryogenics from electrical connections, allowing even inexperienced users to conduct testing by simply mounting their ASIC on a removable electrical insert. Thermal connections between the cold stages and the inserts are made with robust thermal links. ICE-T accommodates two independent electrical inserts at the same time. We have designed various inserts, such as universal ones with all 40 or 80 coaxial cables and those with customized wiring and temperature-controlled stages. ICE-T features fast thermal cycling for rapid testing, enables detailed testing over long periods (days to months, if necessary), and even supports automated testing of digital ICs with modular additions.
Development of a reliable method to assess footwear comfort during running.
Mündermann, Anne; Nigg, Benno M; Stefanyshyn, Darren J; Humble, R Neil
2002-08-01
The purposes of this study were: (a) to determine whether subjects are able to distinguish between differences in footwear with respect to footwear comfort; and (b) to determine how reliably footwear comfort can be assessed using a visual analogue scale (VAS) and a protocol including a control condition during running. Intraclass correlation coefficients (ICCs) between comfort ratings for repeated conditions were high (ICC = 0.799). Differences in comfort ratings between the insert conditions were significant. A paired t-test revealed a significant difference in overall comfort ratings for the control insert when tested after the soft insert compared to when tested after the hard insert (P = 0.008). The results of this study showed that VASs provide a reliable measure to assess footwear comfort during running under the conditions that: (a) a control condition is included; and (b) the average comfort rating of sessions 4-6 is used. Copyright 2002 Elsevier Science B.V.
Latex improvement of recycled asphalt pavement
NASA Astrophysics Data System (ADS)
Drennon, C.
1982-08-01
The performance of a single unmodified milled recycled asphalt concrete was compared to milled asphalt concrete modified by addition of three types of rubber latex. Latex was added at 2, 3, 5, and 8 percent latex by weight of asphalt in the asphalt concrete. Lattices used were a styrene butadiene (SBR), a natural rubber (NR), an acrylonitrile butadiene (NBR), and four varieties of out of specification SBR lattices. Marshall tests, while indecisive, showed a modest improvement in properties of SBR and NR added material at 3 and 5 percent latex. Addition of NBR latex caused deterioration in Marshall stability and flow over that of control. Repeated load tests were run using the indirect tensile test, analyzed by the VESYS program, which computes life of pavements. Repeated load tests showed improvement in asphalt concrete life when 3 and 5 percent SBR was added. Improvement was also shown by the out of specification SBR.
Species-specific selection on soil fungal population after olive mill waste-water treatment.
Tardioli, S; Bànnè, E; Santori, F
1997-06-01
Soil was treated with olive mill waste water (OMW) in order to study the effect of this agriculture waste on soil fungal population. Changes in fungal composition were observed after soil pollution. In order to test OMW selective pressure, growth kinetics of Penicillium cyclopium, Scopulariopsis brevicaulis and Cladosporium cladosporioides were studied on solid media supplemented with different OMW concentrations. S. brevicaulis and C. cladosporioides did not grow at OMW concentration higher than 50%, while at concentrations lower than 50% a growth decrease was observed. Instead, P. cyclopium was able to actively grow at all concentrations of OMW tested. Therefore the OMW can influence and modify the soil fungal homeostasis.
Evaluating the Legitimacy of Contemporary Legal Strategies for Obesity.
Morain, Stephanie
2015-12-01
Contemporary legal strategies for obesity raise troubling questions regarding individual liberty and the legitimate scope of public health authority. This article argues that the predominant approach to assessing public health legitimacy--John Stuart Mill's "harm principle"--may be unsuitable for evaluating the legitimacy of legal strategies for obesity. The article proposes an alternative test for assessing the legitimate scope of public health authority: John Rawls's liberal principle of legitimacy. It outlines how Rawls's principle would evaluate obesity policies, and contrasts this evaluation to that of Mill. The alternative test avoids some of the limitations of the Millian approach, and may offer an improved mechanism for assessing the liberty effects of policies for obesity and other public health activities.
An on-belt elemental analyser for the cement industry.
Lim, C S; Tickner, J R; Sowerby, B D; Abernethy, D A; McEwan, A J; Rainey, S; Stevens, R; Manias, C; Retallack, D
2001-01-01
On-line control of raw mill feed composition is a key factor in the improved control of cement plants. A new and improved on-conveyor belt elemental analyser for cement raw mill feed based on neutron inelastic scatter and capture techniques has been developed and tested successfully in Adelaide Brighton's Birkenhead cement plant on highly segregated material with a depth range of 100 to 180 mm. Dynamic tests in the plant have shown analyser RMS total errors of 0.49, 0.52, 0.38 and 0.23 wt% (on a loss free basis) for CaO, SiO2, Al2O3 and Fe2O3 respectively, when 10-minute counting periods are used.
The use of transient evoked otoacoustic emissions as a hearing screen following grommet insertion.
Dale, O T; McCann, L J; Thio, D; Wells, S C; Drysdale, A J
2011-07-01
This study aimed to evaluate the sensitivity of transient evoked otoacoustic emission testing as a screening tool for hearing loss in children, after grommet insertion. A prospective study was conducted of 48 children (91 ears) aged three to 16 years who had undergone grommet insertion for glue ear. At post-operative review, pure tone audiometry was performed followed by transient evoked otoacoustic emission testing. Outcomes for both tests, in each ear, were compared. The pure tone audiometry threshold was ≤ 20 dB in 85 ears (93.4 per cent), 25 dB in two ears (2.2 per cent) and ≥ 30 dB in four ears (4.4 per cent). Transient evoked otoacoustic emissions were detected in 69 ears (75.8 per cent). The sensitivity of transient evoked otoacoustic emission testing for detecting hearing loss was 100 per cent for ≥ 30 dB loss but only 66.7 per cent for ≥ 25 dB loss. Transient evoked otoacoustic emission testing offers a sensitive means of detecting hearing loss of ≥ 30 dB following grommet insertion in children. However, the use of such testing as a screening tool may miss some cases of mild hearing loss.
Steiner, Denise; Finke, Jan Henrik; Kwade, Arno
2016-09-25
Orodispersible films possess a great potential as a versatile platform for nanoparticle-loaded oral dosage forms. In this case, poorly water-soluble organic materials were ground in a stirred media mill and embedded into a polymer matrix. The aim of this study was the shortening of this manufacturing process by the integration of several process steps into a stirred media mill without facing disadvantages regarding the film quality. Furthermore, this process integration is time conserving due to the high stress intensities provided in the mill and applicable for high solids contents and high suspension viscosities. Two organic materials, the model compound Anthraquinone and the active pharmaceutical ingredient Naproxen were investigated in this study. Besides the impact of the film processing on the crystallinity of the particles in the orodispersible film, a particle load of up to 50% was investigated with the new developed processing route. Additionally, a disintegration test was developed, combining an appropriate amount of saliva substitute and a clear endpoint determination. In summary, high nanoparticle loads in orodispersible films with good particle size preservation after film redispersion in water as well as a manufacturing of the film casting mass within a few minutes in a stirred media mill was achieved. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Stout, Matthew
The purpose of this study is to explore the feasibility of yttria-stabilized zirconia (Y-TZP) in fixed lingual retention as an alternative to stainless steel. Exploratory Y-TZP specimens were milled to establish design parameters. Next, specimens were milled according to ASTM standard C1161-13 and subjected to four-point flexural test to determine materials properties. Finite Element (FE) Analysis was employed to evaluate nine novel cross-sectional designs and compared to stainless steel wire. Each design was analyzed under the loading conditions to determine von Mises and bond stress. The most promising design was fabricated to assess accuracy and precision of current CAD/CAM milling technology. The superior design had a 1.0 x 0.5 mm semi-elliptical cross section and was shown to be fabricated reliably. Overall, the milling indicated a maximum percent standard deviation of 9.3 and maximum percent error of 13.5 with a cost of $30 per specimen. Y-TZP can be reliably milled to dimensions comparable to currently available metallic retainer wires. Further research is necessary to determine the success of bonding protocol and clinical longevity of Y-TZP fixed retainers. Advanced technology is necessary to connect the intraoral scan to an aesthetic and patient-specific Y-TZP fixed retainer.
Xiaopeng, Wang; Fantao, Kong; Biqing, Han; Yuyong, Chen
2017-11-01
Ti-Nb-Sn-hydroxyapatite (HA) composites were prepared by mechanical alloying for different times (unmilled, 4, 8 and 12h), followed by pulse current activated sintering. The effects of the milling time on the electrochemical corrosion resistance and bioactivity of the sintered Ti-35Nb-2.5Sn-15HA composites were investigated. Potentiodynamic polarization test results indicated that the sintered Ti-35Nb-2.5Sn-15HA composites exhibited higher corrosion resistance with increasing milling time. The corrosion potential and current of the Ti-35Nb-2.5Sn-15HA composite sintered by 12h milled powders were - 0.261V and 0.18μA/cm 2 , respectively, and this sintered composite showed a stable and wide passivation region. The hemolysis rate of the sintered Ti-35Nb-2.5Sn-15HA composites reduced with increasing milling time and the lowest hemolytic rate of the composites was 0.87%. In addition, the in vitro cell culture results indicated that the composite sintered by 12h milled powders had good biocompatibility. These results indicate the significant potential of Ti-35Nb-2.5Sn/xHA composites for biomedical implant applications. Copyright © 2017 Elsevier Ltd. All rights reserved.
MIL-L-87177 and CLT:X-10 Lubricants Improve Electrical Connector Fretting Corrosion Behavior
DOE Office of Scientific and Technical Information (OSTI.GOV)
AUKLAND,NEIL R.; HANLON,JAMES T.
1999-10-12
We have conducted a fretting research project using MIL-L-87177 and CLT: X-10 lubricants on Nano-miniature connectors. When they were fretted without lubricant, individual connectors first exceeded our 0.5 ohm failure criteria from 2,341 to 45,238 fretting cycles. With additional fretting, their contact resistance increased to more than 100,000 ohms. Unmodified MIL-L-87177 lubricant delayed the onset of first failure to between 430,000 and over 20,000,000 fretting cycles. MIL-L-87177 modified by addition of Teflon powder delayed first failure to beyond 5 million fretting cycles. Best results were obtained when Teflon was used and also when both the straight and modified lubricants weremore » poured into and then out of the connector. CLT: X-10 lubricant delayed the onset of first failure to beyond 55 million cycles in one test where a failure was actually observed and to beyond 20 million cycles in another that was terminated without failure. CLT: X-10 recovered an unlubricated connector driven deeply into failure, with six failed pins recovering immediately and four more recovering during an additional 420 thousand fretting cycles. MIL-L-87177 was not able to recover a connector under similar conditions.« less
On the bistable zone of milling processes
Dombovari, Zoltan; Stepan, Gabor
2015-01-01
A modal-based model of milling machine tools subjected to time-periodic nonlinear cutting forces is introduced. The model describes the phenomenon of bistability for certain cutting parameters. In engineering, these parameter domains are referred to as unsafe zones, where steady-state milling may switch to chatter for certain perturbations. In mathematical terms, these are the parameter domains where the periodic solution of the corresponding nonlinear, time-periodic delay differential equation is linearly stable, but its domain of attraction is limited due to the existence of an unstable quasi-periodic solution emerging from a secondary Hopf bifurcation. A semi-numerical method is presented to identify the borders of these bistable zones by tracking the motion of the milling tool edges as they might leave the surface of the workpiece during the cutting operation. This requires the tracking of unstable quasi-periodic solutions and the checking of their grazing to a time-periodic switching surface in the infinite-dimensional phase space. As the parameters of the linear structural behaviour of the tool/machine tool system can be obtained by means of standard modal testing, the developed numerical algorithm provides efficient support for the design of milling processes with quick estimates of those parameter domains where chatter can still appear in spite of setting the parameters into linearly stable domains. PMID:26303918
Eliminating impingement optimizes patellar biomechanics in high knee flexion.
Tang, Qi-heng; Zhou, Yi-xin; Tang, Jing; Shao, Hong-yi; Wang, Guang-zhi
2010-08-01
We investigated the impact of eliminating the impingement between extensor mechanism and tibial insert on patellar tracking and patellar ligament tension in high knee flexion. Six cadaveric specimens were tested on an Oxford-type testing rig. The Genesis II knee system was implanted into each specimen knee with the traditional tibial insert and high-flex insert successively. Compared to traditional insert, the high-flex insert was characterized with a chambered anterior post and a chambered anterior lip which eliminates patella-post and patellar ligament-anterior lip impingements. The patella was tracked with an NDI Optotrak Certus system. The patellar ligament tension was measured using a NKB S-type tension transducer. There was a decrease of resultant patellar translation relative to the femur with statistically significant (P<0.05) at 90 degrees to 150 degrees of knee flexion and a decrease of patellar ligament tension with statistical significance (P<0.05) at 100 degrees, 120 degrees, 130 degrees, and 140 degrees of flexion using high-flex insert compared to traditional insert. Eliminating the impingement between extensor mechanism and implant in high knee flexion altered patellar tracking and reduced patellar ligament tension, which would facilitate high knee flexion.
Sarfraz, Muhammad; Griffin, Sharoon; Gabour Sad, Tamara; Alhasan, Rama; Nasim, Muhammad Jawad; Irfan Masood, Muhammad; Schäfer, Karl Herbert; Ejike, Chukwunonso E C C; Keck, Cornelia M; Jacob, Claus; Ebokaiwe, Azubuike P
2018-04-20
Nanosizing represents a straight forward technique to unlock the biological activity of complex plant materials. The aim of this study was to develop herbal nanoparticles with medicinal value from dried leaves and stems of Loranthus micranthus with the aid of ball-milling, high speed stirring, and high-pressure homogenization techniques. The milled nanoparticles were characterized using laser diffraction analysis, photon correlation spectroscopy analysis, and light microscopy. The average size of leaf nanoparticles was around 245 nm and that of stem nanoparticles was around 180 nm. The nanoparticles were tested for their antimicrobial and nematicidal properties against a Gram-negative bacterium Escherichia coli , a Gram-positive bacterium Staphylococcus carnosus , fungi Candida albicans and Saccharomyces cerevisiae , and a nematode Steinernemafeltiae . The results show significant activities for both leaf and (particularly) stem nanoparticles of Loranthus micranthus on all organisms tested, even at a particle concentration as low as 0.01% ( w / w ). The results observed indicate that nanoparticles (especially of the stem) of Loranthus micranthus could serve as novel antimicrobial agents with wide-ranging biomedical applications.
Boulaadjoul, Soumia; Zemmouri, Hassiba; Bendjama, Zoubida; Drouiche, Nadjib
2018-05-02
In this study, Moringa oleifera (M. oleifera) performance as an eco-friendly coagulant in the enhanced primary treatment of paper mill effluent was investigated. Its performance in terms of turbidity removal and COD abatement was examined. Local M. oleifera seed powder from ADRAR-city, South of Algeria, was used. Conventional jar tests were conducted for enhancing the primary treatment of paper mill effluent from paper factory. For this reason, comparative coagulation tests were performed using aluminum sulfate (alum). Indeed, in terms of turbidity abatement, 96.02% and 97.1% were obtained for Moringa and alum, respectively. However, in the case of COD abatement, the abatement rate of M. oleifera seeds was slightly higher than that of alum, 97.28% and 92.67%, respectively. Because M. oleifera is a natural resource that is locally available, an eco-friendly coagulant, non-toxic, and biodegradable and does not affect the pH of water; thus, its use allows to avoid numerous disadvantages of conventional coagulants like alum. Copyright © 2018 Elsevier Ltd. All rights reserved.
Controlled cooling technology for bar and rod mills -- Computer simulation and operational results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mauk, P.J.; Kruse, M.; Plociennik, U.
The Controlled Cooling Technology (CCT) developed by SMS to simulate the rolling process and automatic control of the water cooling sections is presented. The Controlled Rolling and Cooling Technology (CRCT) model is a key part of the CCT system. It is used to simulate temperature management for the rolling stock on the computer before the actual rolling process takes place. This makes it possible to dispense with extensive rolling tests in the early stages of project planning and to greatly reduce the extent of such tests prior to the start of commercial production in a rolling mill. The CRCT modelmore » has been in use at Von Moos Stahl Ag for three years. It demonstrates that, by targeted improvement of the set-up values in both the technology and the plant, it is possible to improve microstructure quality and achieve better geometrical parameters in the rolled products. Also, the results gained with the CCT system in practical operation at the Kia Steel Bar Mill, Kunsan, Korea, are presented.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-23
... of showerhead and hand-held showerhead; removal of body sprays from the proposed showerhead... standardized test method to be used when verifying the mechanical retention of a showerhead flow control insert... Faucets 1. Definitions 2. Test Procedure for Showerhead Flow Control Insert [[Page 62971
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moore, Robert C.; Szecsody, James; Rigali, Mark J.
We have performed an initial evaluation and testing program to assess the effectiveness of a hydroxyapatite (Ca10(PO4)6(OH)2) permeable reactive barrier and source area treatment to decrease uranium mobility at the Department of Energy (DOE) former Old Rifle uranium mill processing site in Rifle, western Colorado. Uranium ore was processed at the site from the 1940s to the 1970s. The mill facilities at the site as well as the uranium mill tailings previously stored there have all been removed. Groundwater in the alluvial aquifer beneath the site still contains elevated concentrations of uranium, and is currently used for field tests tomore » study uranium behavior in groundwater and investigate potential uranium remediation technologies. The technology investigated in this work is based on in situ formation of apatite in sediment to create a subsurface apatite PRB and also for source area treatment. The process is based on injecting a solution containing calcium citrate and sodium into the subsurface for constructing the PRB within the uranium plume. As the indigenous sediment micro-organisms biodegrade the injected citrate, the calcium is released and reacts with the phosphate to form hydroxyapatite (precipitate). This paper reports on proof-of-principle column tests with Old Rifle sediment and synthetic groundwater.« less
Characterization of the performance of shoe insert materials.
Lewis, G; Tan, T; Shiue, Y S
1991-08-01
It has been widely reported that shoe inserts are an effective interventional modality either for the relief of discomfort to the feet associated with a variety of orthopedic disorders or conditions or simply for comfort. Results from many types of experimental tests have been used to obtain the shock absorption capacity of shoe insert materials. The authors contend in this study that, while shock absorption is a highly desirable property, it is by no means the only that should be used to characterize these materials. Thus, a new index of performance of these materials is proposed. This index is computed from data, obtained in a simple experimental test, on both the shock absorption and energy return performances of the insert material.
Charcoal as a capture material for silver nanoparticles in the aquatic environment
NASA Astrophysics Data System (ADS)
McGillicuddy, Eoin; Morrison, Liam; Cormican, Martin; Morris, Dearbháile
2017-04-01
Background: The reported antibacterial activity of silver nanoparticles (AgNPs) has led to their incorporation into numerous consumer products including; textiles, domestic appliances, food containers, cosmetics, paints, medical and medicinal products. The AgNPs incorporated into these products can be released into the environment and aquatic system during their production, use and end of life disposal. In the aquatic environment, uncertainties surround the concentration, fate and effects of AgNPs. The aim of this project is to examine charcoal as a potential material for capture of silver nanoparticles from the aquatic environment. Material/methods: Activated charcoal is a commonly used filter material and was selected for this project to determine its suitability as a capture material for AgNPs in water samples. Activated charcoal (Norit® CA1 (Sigma-Aldrich)) was exposed to 100 ppb, 25 nm PVP coated AgNPs (nanoComposix) prepared in Milli-Q water. These solutions were exposed to unaltered charcoal granules for 20 hours after which the decrease of silver in the solution was measured using ICP-MS. In order to improve the removal, the surface area of the charcoal was increased firstly by grinding with a pestle and mortar and secondly by milling the charcoal. The milled charcoal was prepared using an agate ball mill running at 500 rpm for 5 minutes. The activated charcoal was then exposed to samples containing 10 ppb AgNPs. Results: In the initial tests, approximately 10% of the silver was removed from the water samples using the unaltered activated charcoal granules. Further experiments were carried out to compare the unaltered granules with the ground and milled charcoal. These tests were carried out similarly to the previous test however lower concentration of 10 ppb was used. After 20 hours of exposure the granule samples, as previously, showed approximately a 10% reduction in silver content with the ground charcoal giving approximately 30% reduction in silver concentration and in the sample exposed to milled charcoal, approximately 60% reduction in silver concentration was observed. These tests found that increasing the surface area of the charcoal increased the silver reduction in the solution. Conclusions: Data suggest that charcoal may be a suitable material for use in the capture of AgNPs from water samples
Walking adaptability therapy after stroke: study protocol for a randomized controlled trial.
Timmermans, Celine; Roerdink, Melvyn; van Ooijen, Marielle W; Meskers, Carel G; Janssen, Thomas W; Beek, Peter J
2016-08-26
Walking in everyday life requires the ability to adapt walking to the environment. This adaptability is often impaired after stroke, and this might contribute to the increased fall risk after stroke. To improve safe community ambulation, walking adaptability training might be beneficial after stroke. This study is designed to compare the effects of two interventions for improving walking speed and walking adaptability: treadmill-based C-Mill therapy (therapy with augmented reality) and the overground FALLS program (a conventional therapy program). We hypothesize that C-Mill therapy will result in better outcomes than the FALLS program, owing to its expected greater amount of walking practice. This is a single-center parallel group randomized controlled trial with pre-intervention, post-intervention, retention, and follow-up tests. Forty persons after stroke (≥3 months) with deficits in walking or balance will be included. Participants will be randomly allocated to either C-Mill therapy or the overground FALLS program for 5 weeks. Both interventions will incorporate practice of walking adaptability and will be matched in terms of frequency, duration, and therapist attention. Walking speed, as determined by the 10 Meter Walking Test, will be the primary outcome measure. Secondary outcome measures will pertain to walking adaptability (10 Meter Walking Test with context or cognitive dual-task and Interactive Walkway assessments). Furthermore, commonly used clinical measures to determine walking ability (Timed Up-and-Go test), walking independence (Functional Ambulation Category), balance (Berg Balance Scale), and balance confidence (Activities-specific Balance Confidence scale) will be used, as well as a complementary set of walking-related assessments. The amount of walking practice (the number of steps taken per session) will be registered using the treadmill's inbuilt step counter (C-Mill therapy) and video recordings (FALLS program). This process measure will be compared between the two interventions. This study will assess the effects of treadmill-based C-Mill therapy compared with the overground FALLS program and thereby the relative importance of the amount of walking practice as a key aspect of effective intervention programs directed at improving walking speed and walking adaptability after stroke. Netherlands Trial Register NTR4030 . Registered on 11 June 2013, amendment filed on 17 June 2016.
Effect of shoe insert construction on foot and leg movement.
Nigg, B M; Khan, A; Fisher, V; Stefanyshyn, D
1998-04-01
The purpose of this study was to quantify changes in foot eversion and tibial rotation during running resulting from systematic changes of material composition of five shoe inserts of the same shape. Tests were performed with 12 subjects. The inserts had a bilayer design using two different materials at the top and bottom of the insert. The functional kinematic variables examined in this study were the foot-leg in-eversion angle, beta, and the leg-foot tibial rotation, rho. Additionally, the subject characteristics of arch height, relative arch deformation, and active range of motion were quantified. The statistical analysis used was a two way repeated measures MANOVA (within trials and inserts). The average group changes resulting from the studied inserts in total shoe eversion, total foot eversion, and total internal tibial rotation were typically smaller than 1 degree when compared with the no-insert condition and were statistically not significant. The measured ranges of total foot eversion for all subjects were smallest for the softest and about twice as large for the hardest insert construction. Thus, the soft insert construction was more restrictive, forcing all feet into a similar movement pattern, whereas the harder combinations allowed for more individual variation of foot and leg movement and did not force the foot into a preset movement pattern. The individual results showed substantial differences between subjects and a trend: Subjects who generally showed a reduction of tibial rotation with all tested inserts typically had a flexible foot. However, subjects who generally showed an increase of tibial rotation typically had a stiff foot. The results of this study suggest that subject specific factors such as static, dynamic, and neuro-physiological characteristics of foot and leg are important to match specific feet and shoe inserts optimally.
RERTR-12 Insertion 2 Irradiation Summary Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. M. Perez; G. S. Chang; D. M. Wachs
2012-09-01
The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-12 was designed to provide comprehensive information on the performance of uranium-molybdenum (U-Mo) based monolithic fuels for research reactor applications.1 RERTR-12 insertion 2 includes the capsules irradiated during the last three irradiation cycles. These capsules include Z, Y1, Y2 and Y3 type capsules. The following report summarizes the life of the RERTR-12 insertion 2 experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.
3D kinematics of mobile-bearing total knee arthroplasty using X-ray fluoroscopy.
Yamazaki, Takaharu; Futai, Kazuma; Tomita, Tetsuya; Sato, Yoshinobu; Yoshikawa, Hideki; Tamura, Shinichi; Sugamoto, Kazuomi
2015-04-01
Total knee arthroplasty (TKA) 3D kinematic analysis requires 2D/3D image registration of X-ray fluoroscopic images and a computer-aided design (CAD) model of the knee implant. However, these techniques cannot provide information on the radiolucent polyethylene insert, since the insert silhouette does not appear clearly in X-ray images. Therefore, it is difficult to obtain the 3D kinematics of the polyethylene insert, particularly the mobile-bearing insert. A technique for 3D kinematic analysis of a mobile-bearing insert used in TKA was developed using X-ray fluoroscopy. The method was tested and a clinical application was evaluated. Tantalum beads and a CAD model of the mobile-bearing TKA insert are used for 3D pose estimation of the mobile-bearing insert used in TKA using X-ray fluoroscopy. The insert model was created using four identical tantalum beads precisely located at known positions in a polyethylene insert using a specially designed insertion device. Finally, the 3D pose of the insert model was estimated using a feature-based 2D/3D registration technique, using the silhouette of beads in fluoroscopic images and the corresponding CAD insert model. In vitro testing for the repeatability of the positioning of the tantalum beads and computer simulations for 3D pose estimation of the mobile-bearing insert were performed. The pose estimation accuracy achieved was sufficient for analyzing mobile-bearing TKA kinematics (RMS error: within 1.0 mm and 1.0°, except for medial-lateral translation). In a clinical application, nine patients with mobile-bearing TKA were investigated and analyzed with respect to a deep knee bending motion. A 3D kinematic analysis technique was developed that enables accurate quantitative evaluation of mobile-bearing TKA kinematics. This method may be useful for improving implant design and optimizing TKA surgical techniques.
Abduo, Jaafar; Chen, Chen; Le Breton, Eugene; Radu, Alexandra; Szeto, Josephine; Judge, Roy; Darby, Ivan
To compare the Encode impression protocol (Biomet 3i) with the conventional impression protocol in terms of treatment duration, clinical accuracy, and outcome up to the first postplacement review of single-implant crowns. A total of 45 implants were included in this study. The implants were randomly allocated to the Encode group (23 implants) or the conventional group (22 implants). At the time of surgery, all implants received two-piece Encode healing abutments. The implants were restored 3 months after insertion. In the conventional protocol, open-tray implant-level impressions were taken and the implants were restored with prefabricated abutments and porcelain-fused-to-metal (PFM) crowns. For the implants in the Encode group, closed-tray impressions of the healing abutments were taken. The generated casts were sent to the Biomet 3i scanning/milling center for custom abutment manufacturing on which PFM crowns were fabricated. Treatment duration (laboratory and clinical), clinical accuracy of occlusal and proximal contacts, and outcome (esthetics, patient satisfaction, and crown contour) were evaluated with the aid of a series of questionnaires. The Encode protocol required significantly less laboratory time (18 minutes) than the conventional protocol for adjustment of the abutments. The impression pour time, time for the laboratory to return the crown, time for crown insertion at the final appointment, and total clinical time for crown insertion did not differ significantly between the two protocols. Likewise, clinical accuracy, esthetics, and patient satisfaction were similar for the two protocols. The two protocols were clinically comparable. The Encode protocol is advantageous in reducing the laboratory time before crown fabrication.
Liu, Bo; Peng, Tongjiang; Sun, Hongjuan
2017-06-01
Pollution by the release of heavy metals from tailings constitutes a potential threat to the environment. To characterize the processes governing the release of Mn, Sr, Pb, and U from the uranium mill tailings, a dynamic leaching test was applied for different size of uranium mill tailings samples. Inductively coupled plasma atomic emission spectroscopy (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS) were performed to determine the content of Mn, Sr, Pb, and U in the leachates. The release of mobile Mn, Sr, Pb, and U fraction was slow, being faster in the initial stage and then attained a near steady-state condition. The experimental results demonstrate that the release of Mn, Sr, Pb, and U from uranium mill tailings with different size fractions is controlled by a variety of mechanisms. Surface wash-off is the release mechanism for Mn. The main release mechanism of Sr and Pb is the dissolution in the initial leaching stage. For U, a mixed process of wash-off and diffusion is the controlling mechanism.
Ribeiro, Renato Cesar de Azevedo; Barreto, Stella Maria de Andrade Gomes; Ostrosky, Elissa Aarantes; da Rocha-Filho, Pedro Alves; Veríssimo, Lourena Mafra; Ferrari, Márcio
2015-02-02
This study aimed to produce and characterize an oil in water (O/W) nanoemulsion containing Opuntia ficus-indica (L.) Mill hydroglycolic extract, as well as evaluate its preliminary and accelerated thermal stability and moisturizing efficacy. The formulations containing 0.5% of xanthan gum (FX) and 0.5% of xanthan gum and 1% of Opuntia ficus-indica MILL extract (FXE) were white, homogeneus and fluid in aspect. Both formulations were stable during preliminary and accelerated stability tests. FX and FXE presented a pH compatible to skin pH (4.5-6.0); droplet size varying from 92.2 to 233.6 nm; a polydispersion index (PDI) around 0.200 and a zeta potential from -26.71 to -47.01 mV. FXE was able to increase the water content of the stratum corneum for 5 h after application on the forearm. The O/W nanoemulsions containing 1% of Opuntia ficus-indica (L.) Mill extract presented suitable stability for at least for 60 days. Besides, this formulation was able to increase the water content of stratum corneum, showing its moisturizing efficacy.
31. RW Meyer Sugar Mill: 18761889. Threeroll sugar mill: oneton ...
31. RW Meyer Sugar Mill: 1876-1889. Three-roll sugar mill: one-ton daily processing capacity. Manufactured by Edwin Maw, Liverpool, England, ca. 1855-1870. View: View down at the mill from top of the mill's circular masonry enclosure. Mill animals circling above the mill, on top of the enclosure, dragged booms radiating from the drive shaft to power the mill. The drive-shaft is no longer in its upright positon but is lying next to the mill in the foreground. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI
Neural and Neural Gray-Box Modeling for Entry Temperature Prediction in a Hot Strip Mill
NASA Astrophysics Data System (ADS)
Barrios, José Angel; Torres-Alvarado, Miguel; Cavazos, Alberto; Leduc, Luis
2011-10-01
In hot strip mills, initial controller set points have to be calculated before the steel bar enters the mill. Calculations rely on the good knowledge of rolling variables. Measurements are available only after the bar has entered the mill, and therefore they have to be estimated. Estimation of process variables, particularly that of temperature, is of crucial importance for the bar front section to fulfill quality requirements, and the same must be performed in the shortest possible time to preserve heat. Currently, temperature estimation is performed by physical modeling; however, it is highly affected by measurement uncertainties, variations in the incoming bar conditions, and final product changes. In order to overcome these problems, artificial intelligence techniques such as artificial neural networks and fuzzy logic have been proposed. In this article, neural network-based systems, including neural-based Gray-Box models, are applied to estimate scale breaker entry temperature, given its importance, and their performance is compared to that of the physical model used in plant. Several neural systems and several neural-based Gray-Box models are designed and tested with real data. Taking advantage of the flexibility of neural networks for input incorporation, several factors which are believed to have influence on the process are also tested. The systems proposed in this study were proven to have better performance indexes and hence better prediction capabilities than the physical models currently used in plant.
Maintenance coating of weathering steel : field evaluation and guidelines
DOT National Transportation Integrated Search
1995-03-01
This report describes a 4-year bridge and test fence evaluation of protective coatings for maintaining weathering steel bridges. The test specimens consisted of steel panels cut from existing aged weathering steel bridges, along with some new mill sc...
Li, Meng; Zhang, Lu; Davé, Rajesh N; Bilgili, Ecevit
2016-04-01
As a drug-sparing approach in early development, vibratory milling has been used for the preparation of nanosuspensions of poorly water-soluble drugs. The aim of this study was to intensify this process through a systematic increase in vibration intensity and bead loading with the optimal bead size for faster production. Griseofulvin, a poorly water-soluble drug, was wet-milled using yttrium-stabilized zirconia beads with sizes ranging from 50 to 1500 μm at low power density (0.87 W/g). Then, this process was intensified with the optimal bead size by sequentially increasing vibration intensity and bead loading. Additional experiments with several bead sizes were performed at high power density (16 W/g), and the results were compared to those from wet stirred media milling. Laser diffraction, scanning electron microscopy, X-ray diffraction, differential scanning calorimetry, and dissolution tests were used for characterization. Results for the low power density indicated 800 μm as the optimal bead size which led to a median size of 545 nm with more than 10% of the drug particles greater than 1.8 μm albeit the fastest breakage. An increase in either vibration intensity or bead loading resulted in faster breakage. The most intensified process led to 90% of the particles being smaller than 300 nm. At the high power intensity, 400 μm beads were optimal, which enhanced griseofulvin dissolution significantly and signified the importance of bead size in view of the power density. Only the optimally intensified vibratory milling led to a comparable nanosuspension to that prepared by the stirred media milling.
Sound attenuation of fiberglass lined ventilation ducts
NASA Astrophysics Data System (ADS)
Albright, Jacob
Sound attenuation is a crucial part of designing any HVAC system. Most ventilation systems are designed to be in areas occupied by one or more persons. If these systems do not adequately attenuate the sound of the supply fan, compressor, or any other source of sound, the affected area could be subject to an array of problems ranging from an annoying hum to a deafening howl. The goals of this project are to quantify the sound attenuation properties of fiberglass duct liner and to perform a regression analysis to develop equations to predict insertion loss values for both rectangular and round duct liners. The first goal was accomplished via insertion loss testing. The tests performed conformed to the ASTM E477 standard. Using the insertion loss test data, regression equations were developed to predict insertion loss values for rectangular ducts ranging in size from 12-in x 18-in to 48-in x 48-in in lengths ranging from 3ft to 30ft. Regression equations were also developed to predict insertion loss values for round ducts ranging in diameters from 12-in to 48-in in lengths ranging from 3ft to 30ft.
NASA Technical Reports Server (NTRS)
Murri, Gretchen Bostaph; Martin, Roderick H.
1991-01-01
Static and fatigue double-cantilever beam (DCB) and end-notch flexure (ENF) tests were conducted to determine the effect of the simulated initial delamination in interlaminar fracture toughness, G(sub c), and fatigue fracture threshold, G(sub th). Unidirectional, 24-ply specimens of S2/SP250 glass/epoxy were tested using Kapton inserts of four different thickness - 13, 25, 75, and 130 microns, at the midplane at one end, or with tension or shear precracks, to simulate an initial delamination. To determine G(sub c), the fatigue fracture threshold below which no delamination growth would occur in less than 1 x 10(exp 6) cycles, fatigue tests were conducted by cyclically loading specimens until delamination growth was detected. Consistent values of model 1 fracture toughness, G(sub Ic), were measured from DCB specimens with inserts of thickness 75 microns or thinner, or with shear precracks. The fatigue DCB tests gave similar values of G(sub Ith) for the 13, 25, and 75 microns specimens. Results for the shear precracked specimens were significantly lower that for specimens without precracks. Results for both the static and fatigue ENF tests showed that measured G(IIc) and G(IIth) values decreased with decreasing insert thickness, so that no limiting thickness could be determined. Results for specimens with inserts of 75 microns or thicker were significantly higher than the results for precracked specimens or specimens with 13 or 25 microns inserts.
NASA Technical Reports Server (NTRS)
Smith, Russ; Hagen, Richard
2015-01-01
In support of the Deep Space Habitat project a number of composite rack prototypes were developed, designed, fabricated and tested to various extents ( with the International Standard Payload Rack configuration, or crew quarters, as a baseline). This paper focuses specifically on a composite rack prototype with a direct tie in to Space Station hardware. The outlined prototype is an all composite construction, excluding metallic fasteners, washers, and their associated inserts. The rack utilizes braided carbon composite tubing for the frame with the sidewalls, backwall and flooring sections utilizing aircraft grade composite honeycomb sandwich panels. Novel additively manufactured thermoplastic joints and tube inserts were also developed in support of this effort. Joint and tube insert screening tests were conducted at a preliminary level. The screening tests allowed for modification, and enhancement, of the fabrication and design approaches, which will be outlined. The initial joint tests did not include mechanical fasteners. Adhesives were utilized at the joint to composite tube interfaces, along with mechanical fasteners during final fabrication (thus creating a stronger joint than the adhesive only variant). In general the prototype was focused on a potential in-space assembly approach, or kit-of-parts construction concept, which would not necessarily require the inclusion of an adhesive in the joint regions. However, given the tie in to legacy Station hardware (and potential flight loads with imbedded hardware mass loadings), the rack was built as stiff and strong as possible. Preliminary torque down tests were also conducted to determine the feasibility of mounting the composite honeycomb panels to the composite tubing sections via the additively manufactured tube inserts. Additional fastener torque down tests were also conducted with inserts (helicoils) imbedded within the joints. Lessons learned are also included and discussed.
Scranton, Pierce E; Lawhon, S Michael; McDermott, John E
2005-07-01
Suture anchors have been developed for the fixation of ligaments, capsules, or tendons to bone. These devices have led to improved fixation, smaller incisions, earlier limb mobility, and improved outcomes. They were originally developed for use in shoulder reconstructions but are now used in almost all extremities. In the lower leg they are used in the tibia, the talus, the calcaneus, tarsal bones, and phalanges. Nevertheless, techniques for insertion and mechanisms of failure are not well described. Five suture anchors were studied to determine the pullout strength in four distal cadaver femurs and four proximal cadaver tibias from 55- and 62-year-old males. Eight hundred ninety Newton line was used, testing the anchors to failure with an Instron testing device (Instron, Norwood, MA). The anchor devices were inserted randomly and tested blindly (12 tests per anchor device, 60 tests in all). Two anchors in each group tested failed at low loads. Both types of plastic anchors had failures at the eyelet. Average pullout strength varied from 85.4 to 185.6 N. Insertion techniques are specific for each device, and they must be followed for optimal fixation. In this study, in all five groups of anchors tested two of the 12 anchors in each group failed with minimal force. On the basis of this finding we recommend that, if suture anchor fixation is necessary, at least two anchors should be used. Since there appears to be a percentage of failure in all devices, the second anchor can serve as a backup. It is imperative that surgeons be familiar with the insertion techniques of each device before use.
Thermal-hydraulic analysis of the coil test facility for CFETR.
Ren, Yong; Liu, Xiaogang; Li, Junjun; Wang, Zhaoliang; Qiu, Lilong; Du, Shijun; Li, Guoqiang; Gao, Xiang
2016-01-01
Performance test of the China Fusion Engineering Test Reactor (CFETR) central solenoid (CS) and toroidal field (TF) insert coils is of great importance to evaluate the CFETR magnet performance in relevant operation conditions. The superconducting magnet of the coil test facility for CFETR is being designed with the aim of providing a background magnetic field to test the CFETR CS insert and TF insert coils. The superconducting magnet consists of the inner module with Nb 3 Sn coil and the outer module with NbTi coil. The superconducting magnet is designed to have a maximum magnetic field of 12.59 T and a stored energy of 436.6 MJ. An active quench protection circuit and the positive temperature coefficient dump resistor were adopted to transfer the stored magnetic energy. The temperature margin behavior of the test facility for CFETR satisfies the design criteria. The quench analysis of the test facility shows that the cable temperature and the helium pressure inside the jacket are within the design criteria.
Effect of ball milling materials and methods on powder processing of Bi2223 superconductors
NASA Astrophysics Data System (ADS)
Yavuz, M.; Maeda, H.; Vance, L.; Liu, H. K.; Dou, S. X.
1998-10-01
Various milling systems consisting of agate and polypropylene grinding containers, agate and YSZ balls, and dry and wet milling were used in planetary ball-milling and YSZ balls and YSZ container were used in wet and dry attrition milling. The differently milled powders were then evaluated by measurements of particle size, surface area, porosity, size distribution and chemical analysis of the Si, Zr and C contents. The results show that dry milling is much more efficient for particle size reduction in planetary milling than wet milling, whereas wet milling and dry milling gave quite similar results in attrition milling. Meanwhile 0953-2048/11/10/056/img6 contamination was found in powder milled with an agate container with agate balls. Some C contamination from the polypropylene container was detected after milling, but negligible Zr from YSZ balls and C from the grinding carrier (hexane). It was found that after 1 h milling in the planetary mill fracture mechanisms transform from the elastic to the plastic region. Therefore, further milling is not very effective. It was also shown that the Bi2212 phase decomposes into several non-superconducting oxides such as 0953-2048/11/10/056/img7, CuO and a main amorphous phase after extensive dry milling.
NASA Astrophysics Data System (ADS)
Kulecki, P.; Lichańska, E.
2017-12-01
The effect of ball milling powder mixtures of Höganäs pre-alloyed iron Astaloy CrM, low-carbon ferromanganese Elkem, elemental electrolytic Cu and C-UF graphite on the sintered structure and mechanical properties was evaluated. The mixing was conducted using Turbula mixer for 30 minutes and CDI-EM60 frequency inverter for 1 and 2 hours. Milling was performed on 150 g mixtures with (in weight %) CrM + 1% Mn, CrM + 2% Mn, CrM + 1% Mn + 1% Cu and CrM + 2% Mn + 1% Cu, all with 0.6%C. The green compacts were single pressed at 660 MPa according to PN-EN ISO 2740. Sintering was carried out in a laboratory horizontal furnace Carbolite STF 15/450 at 1250°C for 60 minutes in 5%H2 - 95%N2 atmosphere with a heating rate of 75°C/min, followed by sintering hardening at 60°C/min cooling rate. All the steels were characterized by martensitic structures. Mechanical testing revealed that steels based on milled powders have slightly higher mechanical properties compared to those only mixed and sintered. The best combination of mechanical properties, for ball milled CrM + 1% Mn + 1% Cu was UTS 1046 MPa, TRS 1336 MPa and A 1.94%.
Li, Yan; Deng, Jianxin; Zhou, Jun; Li, Xueen
2016-11-01
Corresponding to pre-puncture and post-puncture insertion, elastic and viscoelastic mechanical properties of brain tissues on the implanting trajectory of sub-thalamic nucleus stimulation are investigated, respectively. Elastic mechanical properties in pre-puncture are investigated through pre-puncture needle insertion experiments using whole porcine brains. A linear polynomial and a second order polynomial are fitted to the average insertion force in pre-puncture. The Young's modulus in pre-puncture is calculated from the slope of the two fittings. Viscoelastic mechanical properties of brain tissues in post-puncture insertion are investigated through indentation stress relaxation tests for six interested regions along a planned trajectory. A linear viscoelastic model with a Prony series approximation is fitted to the average load trace of each region using Boltzmann hereditary integral. Shear relaxation moduli of each region are calculated using the parameters of the Prony series approximation. The results show that, in pre-puncture insertion, needle force almost increases linearly with needle displacement. Both fitting lines can perfectly fit the average insertion force. The Young's moduli calculated from the slope of the two fittings are worthy of trust to model linearly or nonlinearly instantaneous elastic responses of brain tissues, respectively. In post-puncture insertion, both region and time significantly affect the viscoelastic behaviors. Six tested regions can be classified into three categories in stiffness. Shear relaxation moduli decay dramatically in short time scales but equilibrium is never truly achieved. The regional and temporal viscoelastic mechanical properties in post-puncture insertion are valuable for guiding probe insertion into each region on the implanting trajectory.
SU-E-J-189: Credentialing of IGRT Equipment and Processes for Clinical Trials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Court, L; Aristophanous, M; Followill, D
2014-06-01
Purpose: Current dosimetry phantoms used for clinical trial credentialing do not directly assess IGRT processes. This work evaluates a custom-built IGRT phantom for credentialing of multiple IGRT modalities and processes. Methods: An IGRT phantom was built out of a low-density body with two inserts. Insert A is used for the CT simulation. Insert B is used for the actual treatment. The inserts contain identical targets in different locations. Relative positions are unknown to the user. The user simulates the phantom (with insert A) as they would a patient, including marking the phantom. A treatment plan is created and sent tomore » the treatment unit. The phantom (with insert B) is then positioned using local IGRT practice. Shifts (planned isocenter, if applicable, and final isocenter) are marked on the phantom using room lasers. The mechanical reproducibility of re-inserting the inserts within the phantom body was tested using repeat high-resolution CT scans. The phantom was tested at 7 centers, selected to include a wide variety of imaging equipment. Results: Mechanical reproducibility was measured as 0.5-0.9mm, depending on the direction. Approaches tested to mark (and transfer) simulation isocenter included lasers, fiducials and reflective markers. IGRT approaches included kV imaging (Varian Trilogy, Brainlab ExacTrac), kV CT (CT-on-rails), kV CBCT (Varian Trilogy, Varian Truebeam, Elekta Agility) and MV CT (Tomotherapy). Users were able to successfully use this phantom for all combinations of equipment and processes. IGRT-based shifts agreed with the truth within 0.8mm, 0.8mm and 1.9mm in the LR, AP, and SI directions, respectively. Conclusion: Based on these preliminary results, the IGRT phantom can be used for credentialing of clinical trials with an action level of 1mm in AP and LR directions, and 2mm in the SI direction, consistent with TG142. We are currently testing with additional institutions with different equipment and processes, including Cyberknife. This project was funded by the Cancer Prevention Research Institute of Texas.« less
Tsintavi, E; Pontillo, N; Dareioti, M A; Kornaros, M
2013-01-01
The possibility of coupling a physicochemical pretreatment (ozonation) with a biological treatment (anaerobic digestion) was investigated for the case of olive mill wastewaters (OMW). Batch ozonation experiments were performed in a glass bubble reactor. The parameters which were tested included the ozone concentration in the inlet gas stream, the reactor temperature and the composition of the liquid medium in terms of raw or fractionated OMW used. In the sequel, ozone-pretreated OMW samples were tested for their biochemical methane potential (BMP) under mesophilic conditions and these results were compared to the BMP of untreated OMW. The ozonation process alone resulted in a 57-76% decrease of total phenols and a 5-18% decrease of total carbohydrates contained in OMW, depending on the experimental conditions. Nevertheless, the ozone-pretreated OMW exhibited lower chemical oxygen demand removal and methane production during BMP testing compared to the untreated OMW.
Application of Odor Sensors to Ore Sorting and Mill Feed Control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michael G. Nelson
2005-08-01
Control of the feed provided to mineral processing facilities is a continuing challenge. Much effort is currently being devoted to overcoming these problems. These projects are usually described under the general headings of Mine-to-Mill Integration or Mine-Mill Optimization. It should be possible to combine the knowledge of ore type, mineralogy, and other characteristics (located in the mine modeling system), with the advanced capabilities of state-of-the-art mill control systems, to achieve an improved level of control in mineral processing that will allow optimization of the mill processes on an almost real-time basis. This is not happening because mill feed it ismore » often treated as a uniform material, when in reality it varies in composition and characteristics. An investigation was conducted to assess the suitability of odor sensors for maintaining traceability in ore production and processing. Commercially available sensors are now used in food processing, environmental monitoring, and other applications and can detect the presence of very small amounts (0.1-500 ppm) of some molecules. An assortment of such molecules could be used to ''tag'' blocks of ore as they are mined, according to their respective characteristics. Then, as the ore came into the mill, an array of ''electronic noses'' could be used to assess its characteristics in real time. It was found that the Cyranose 320{trademark}, a commercially available odor sensor, can easily distinguish among samples of rock marked with almond, cinnamon, citronella, lemon, and orange oils. Further, the sensor could detect mixtures of rocks marked with various combinations of these oils. Treatment of mixtures of galena and silica with odorant compounds showed no detrimental effects on flotation response in laboratory tests. Additional work is recommended to determine how this concept can be extended to the marking of large volumes of materials.« less
The Effect of Intravenous Infiltration Management Program for Hospitalized Children.
Park, Soon Mi; Jeong, Ihn Sook; Kim, Kyoung Lae; Park, Kyung Ju; Jung, Moon Ju; Jun, Seong Suk
2016-01-01
This study aimed to identify the effect of IV infiltration management program among hospitalized children. This was a quasi-experimental study with history comparison group design with 2,894 catheters inserted during 3 months comparison phase and 3,651 catheters inserted during 4 months experimental phase. The intervention was composed of seven activities including applying poster, documentation of catheter insertion, parents education, making infiltration report, assessment of vein condition before inserting catheter, appropriate site selection, and documentation of catheter insertion, and assessment of peripheral catheter insertion site every shift. Data were analyzed using of X2-test, Fisher's exact test. The infiltration incidence rate was 0.9% for experimental group and 4.4% for comparison group, which was significantly different (x2=80.42, p<.001). The catheter maintenance period (p=.035) and infiltration state (p=.039) were significantly different among participants with infiltration between comparison and experimental groups. IV Infiltration management program was founded to be effective in reducing the IV infiltration incidence rate and increasing early detection of IV infiltration. Considering the effect of IV Infiltration management program, we recommend that this infiltration management program would be widely used in the clinical settings. Copyright © 2016 Elsevier Inc. All rights reserved.
Bellone, Rebecca R.; Holl, Heather; Setaluri, Vijayasaradhi; Devi, Sulochana; Maddodi, Nityanand; Archer, Sheila; Sandmeyer, Lynne; Ludwig, Arne; Foerster, Daniel; Pruvost, Melanie; Reissmann, Monika; Bortfeldt, Ralf; Adelson, David L.; Lim, Sim Lin; Nelson, Janelle; Haase, Bianca; Engensteiner, Martina; Leeb, Tosso; Forsyth, George; Mienaltowski, Michael J.; Mahadevan, Padmanabhan; Hofreiter, Michael; Paijmans, Johanna L. A.; Gonzalez-Fortes, Gloria; Grahn, Bruce; Brooks, Samantha A.
2013-01-01
Leopard complex spotting is a group of white spotting patterns in horses caused by an incompletely dominant gene (LP) where homozygotes (LP/LP) are also affected with congenital stationary night blindness. Previous studies implicated Transient Receptor Potential Cation Channel, Subfamily M, Member 1 (TRPM1) as the best candidate gene for both CSNB and LP. RNA-Seq data pinpointed a 1378 bp insertion in intron 1 of TRPM1 as the potential cause. This insertion, a long terminal repeat (LTR) of an endogenous retrovirus, was completely associated with LP, testing 511 horses (χ2=1022.00, p<<0.0005), and CSNB, testing 43 horses (χ2=43, p<<0.0005). The LTR was shown to disrupt TRPM1 transcription by premature poly-adenylation. Furthermore, while deleterious transposable element insertions should be quickly selected against the identification of this insertion in three ancient DNA samples suggests it has been maintained in the horse gene pool for at least 17,000 years. This study represents the first description of an LTR insertion being associated with both a pigmentation phenotype and an eye disorder. PMID:24167615
Bellone, Rebecca R; Holl, Heather; Setaluri, Vijayasaradhi; Devi, Sulochana; Maddodi, Nityanand; Archer, Sheila; Sandmeyer, Lynne; Ludwig, Arne; Foerster, Daniel; Pruvost, Melanie; Reissmann, Monika; Bortfeldt, Ralf; Adelson, David L; Lim, Sim Lin; Nelson, Janelle; Haase, Bianca; Engensteiner, Martina; Leeb, Tosso; Forsyth, George; Mienaltowski, Michael J; Mahadevan, Padmanabhan; Hofreiter, Michael; Paijmans, Johanna L A; Gonzalez-Fortes, Gloria; Grahn, Bruce; Brooks, Samantha A
2013-01-01
Leopard complex spotting is a group of white spotting patterns in horses caused by an incompletely dominant gene (LP) where homozygotes (LP/LP) are also affected with congenital stationary night blindness. Previous studies implicated Transient Receptor Potential Cation Channel, Subfamily M, Member 1 (TRPM1) as the best candidate gene for both CSNB and LP. RNA-Seq data pinpointed a 1378 bp insertion in intron 1 of TRPM1 as the potential cause. This insertion, a long terminal repeat (LTR) of an endogenous retrovirus, was completely associated with LP, testing 511 horses (χ(2)=1022.00, p<0.0005), and CSNB, testing 43 horses (χ(2)=43, p<0.0005). The LTR was shown to disrupt TRPM1 transcription by premature poly-adenylation. Furthermore, while deleterious transposable element insertions should be quickly selected against the identification of this insertion in three ancient DNA samples suggests it has been maintained in the horse gene pool for at least 17,000 years. This study represents the first description of an LTR insertion being associated with both a pigmentation phenotype and an eye disorder.
High productivity mould robotic milling in Al-5083
NASA Astrophysics Data System (ADS)
Urresti, Iker; Arrazola, Pedro Jose; Ørskov, Klaus Bonde; Pelegay, Jose Angel
2018-05-01
Industrial serial robots were usually limited to welding, handling or spray painting operations until very recent years. However, some industries have already realized about their important capabilities in terms of flexibility, working space, adaptability and cost. Hence, currently they are seriously being considered to carry out certain metal machining tasks. Therefore, robot based machining is presented as a cost-saving and flexible manufacturing alternative compared to conventional CNC machines especially for roughing or even pre-roughing of large parts. Nevertheless, there are still some drawbacks usually referred as low rigidity, accuracy and repeatability. Thus, the process productivity is usually sacrificed getting low Material Removal Rates (MRR), and consequently not being competitive. Nevertheless, in this paper different techniques to obtain increased productivity are presented, though an appropriate selection of cutting strategies and parameters that are essential for it. During this research some rough milling tests in Al-5083 are presented where High Feed Milling (HFM) is implemented as productive cutting strategy and the experimental modal analysis named Tap-testing is used for the suitable choice of cutting conditions. Competitive productivity rates are experienced while process stability is checked through the cutting forces measurements in order to prove the effectiveness of the experimental modal analysis for robotic machining.
Cryo-comminution of plastic waste.
Gente, Vincenzo; La Marca, Floriana; Lucci, Federica; Massacci, Paolo; Pani, Eleonora
2004-01-01
Recycling of plastics is a big issue in terms of environmental sustainability and of waste management. The development of proper technologies for plastic recycling is recognised as a priority. To achieve this aim, the technologies applied in mineral processing can be adapted to recycling systems. In particular, the improvement of comminution technologies is one of the main actions to improve the quality of recycled plastics. The aim of this work is to point out suitable comminution processes for different types of plastic waste. Laboratory comminution tests have been carried out under different conditions of temperature and sample pre-conditioning adopting as refrigerant agents CO2 and liquid nitrogen. The temperature has been monitored by thermocouples placed in the milling chamber. Also different internal mill screens have been adopted. A proper procedure has been set up in order to obtain a selective comminution and a size reduction suitable for further separation treatment. Tests have been performed on plastics coming from medical plastic waste and from a plant for spent lead batteries recycling. Results coming from different mill devices have been compared taking into consideration different indexes for representative size distributions. The results of the performed tests show as cryo-comminution improves the effectiveness of size reduction of plastics, promotes liberation of constituents and increases specific surface size of comminuted particles in comparison to a comminution process carried out at room temperature. Copyright 2004 Elsevier Ltd.
Z-2 Threaded Insert Design and Testing Abstract
NASA Technical Reports Server (NTRS)
Rhodes, RIchard; Graziosi, Dave; Jones, Bobby; Ferl, Jinny; Scarborough, Steve; Sweeney, Mitch
2016-01-01
The Z-2 Prototype Planetary Extravehicular Space Suit Assembly is a continuation of NASA's Z series of spacesuits. The Z-2 is another step in the NASA's technology development roadmap leading to human exploration of the Martian surface. To meet a more challenging set of requirements than previous suit systems standard design features, such as threaded inserts, have been re-analyzed and improved. NASA's Z-2 prototype space suit contains several components fabricated from an advanced hybrid composite laminate consisting of IM10 carbon fiber and fiber glass. One requirement NASA levied on the suit composites was the ability to have removable, replaceable helicoil inserts to which other suit components would be fastened. An approach utilizing bonded in inserts with helicoils inside of them was implemented. The design of the interface flanges of the composites allowed some of the inserts to be a "T" style insert that was installed through the entire thickness of the laminate. The flange portion of the insert provides a mechanical lock as a redundancy to the adhesive aiding in the pullout load that the insert can withstand. In some locations it was not possible to utilize at "T" style insert and a blind insert was used instead. These inserts rely completely on the bond strength of the adhesive to resist pullout. It was determined during the design of the suit that the inserts did not need to withstand loads induced from pressure cycling but instead tension induced from torqueing the screws to bolt on hardware which creates a much higher stress on them. Bolt tension is determined by dividing the torque on the screw by a k value multiplied by the thread diameter of the bolt. The k value is a factor that accounts for friction in the system. A common value used for k for a non-lubricated screw is 0.2. The k value can go down by as much as 0.1 if the screw is lubricated which means for the same torque, a much larger tension could be placed on the bolt and insert. This paper summarizes testing that was performed to determine a k value for helicoil inserts in the Z2 suit and how the insert design was modified to resist a higher pull out tension.
NASA Astrophysics Data System (ADS)
Khalighi, Mohammad Mehdi; Delso, Gaspar; Maramraju, Sri Harsha; Deller, Timothy W.; Levin, Craig S.; Glover, Gary H.
2016-10-01
A silicon photomultiplier (SiPM)-based time-of-flight capable PET detector has been integrated with a 70 cm wide-bore 3T MR scanner for simultaneous whole-body imaging (MR750w, GE Healthcare, Waukesha, WI). After insertion of the PET detector, the final PET/MR bore is 60 cm wide (SIGNA PET/MR, GE Healthcare, Waukesha, WI). The MR performance was compared before and after the PET ring insertion. B0 homogeneity, B1+ uniformity of the body coil along with peak B1+, coherent noise, and FBIRN (Function Biomedical Informatics Research Network) tests are used to compare the MR performance. It is shown that B0 homogeneity and coherent noise have not changed according to the system specifications. Peak B1+ is increased by 33% and B1+ inhomogeneity is increased by 4% after PET ring insertion due to a smaller diameter body coil design. The FBIRN test shows similar temporal stability before and after PET ring insertion. Due to a smaller body coil on the PET/MR system, the signal fluctuation to noise ratio (SFNR) and SNR for body receive coil, are improved by 40% and 160% for Echo Planar Imaging (EPI) and spiral sequences respectively. Comparison using RF- and gradient-intensive clinical sequences shows inserting the PET detectors into the wide-bore MRI has not compromised the MR image quality according to these tests.
New hydrogen titanium phosphate sulfate electrodes for Li-ion and Na-ion batteries
NASA Astrophysics Data System (ADS)
Zhao, Ran; Mieritz, Daniel; Seo, Dong-Kyun; Chan, Candace K.
2017-03-01
NASICON-type materials with general formula AxM2(PO4)3 (A = Li or Na, M = Ti, V, and Fe) are promising candidates for Li- and Na-ion batteries due to their open three-dimensional framework structure. Here we report the electrochemical properties of hydrogen titanium phosphate sulfate, H0.4Ti2(PO4)2.4(SO4)0.6 (HTPS), a new mixed polyanion material with NASICON structure. Micron-sized HTPS aggregates with crystallite grain size of ca. 23 nm are synthesized using a sol-gel synthesis in an acidic medium. The properties of the as-synthesized HTPS, ball-milled HTPS, and samples prepared as carbon composites using an in-situ glucose decomposition reaction are investigated. A capacity of 148 mAh g-1 corresponding to insertion of 2 Li+ per formula unit is observed in the ball-milled HTPS over the potential window of 1.5-3.4 V vs. Li/Li+. Lithiation at ca. 2.8 and 2.5 V is determined to occur through filling of the M1 and M2 sites, respectively. Powder X-ray diffraction (PXRD), scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) are used characterize the HTPS before and after cycling. Evaluation of the HTPS in a Na-ion cell is also performed. A discharge capacity of 93 mAh g-1 with sodiation at ca. 2.9 and 2.2 V vs. Na/Na+ is observed.
NASA Astrophysics Data System (ADS)
Sartkulvanich, Partchapol; Al-Zkeri, Ibrahim; Yen, Yung-Chang; Altan, Taylan
2004-06-01
This paper summarizes some of the progress made on FEM simulations of metal cutting processes conducted at the Engineering Research Center (ERC/NSM). Presented research focuses on the performance of various cutting edge geometries (hone and chamfer edges) for different tool materials and specifically on: 1) the effect of round and chamfer edge geometries on the cutting variables in machining carbon steels and 2) the effect of the edge hone size upon the flank wear and burr formation behavior in face milling of A356-T6 aluminum alloy. In the second task, an innovative design of edge preparation with varying hone size around the tool nose is also explored using FEM. In order to model three-dimensional conventional turning and face milling with two-dimensional orthogonal cutting simulations, 2D simulation cross-sections consisting of the cutting speed direction and chip flow direction are selected at different locations along the tool nose radius. Then the geometries of the hone and chamfer edges and their associated tool angles as well as uncut chip thickness are determined on these planes and employed in cutting simulations. The chip flow direction on the tool rake face are obtained by examining the wear grooves on the experimental inserts or estimated by using Oxley's approximation theory of oblique cutting. Simulation results are compared with the available experimental results (e.g. cutting forces) both qualitatively and quantitatively.
Furtado, G P; Ribeiro, L F; Lourenzoni, M R; Ward, R J
2013-01-01
A bifunctional enzyme has been created by fusing two Bacillus subtilis enzymes: the β-1,3-1,4-glucanase (BglS, EC 3.2.1.73) that hydrolyzes plant cell wall β-glucans and the copper-dependent oxidase laccase (CotA, EC 1.10.3.2) that catalyzes the oxidation of aromatic compounds with simultaneous reduction of oxygen to water. The chimeric laccase/β-1,3-1,4-glucanase was created by insertion fusion of the bglS and cotA genes, and expressed in Escherichia coli. The affinity-purified recombinant chimeric enzyme showed both laccase and glucanase activities, with a maximum laccase activity at pH 4.5 and 75°C that showed a V(max) 30% higher than observed for the parental laccase. The maximum glucanase activity in the chimeric enzyme was at pH 6.0 and 50°C, with a slight reduction in V(max) by ∼10% compared with the parental glucanase. A decreased K(M) resulted in an overall increase in the K(cat)/K(M) value for the glucanase activity of the chimeric enzyme. The hydrolytic activity of the chimera was 20% higher against natural milled sugarcane bagasse as compared with equimolar mixtures of the separate parental enzymes. Molecular dynamics simulations indicated the approximation of the two catalytic domains in the chimeric enzyme, and the formation of an inter-domain interface may underlie the improved catalytic function.
30. RW Meyer Sugar Mill: 18761889. Threeroll sugar mill: oneton ...
30. RW Meyer Sugar Mill: 1876-1889. Three-roll sugar mill: one-ton daily processing capacity. Manufactured by Edwin Maw, Liverpool, England, ca. 1885-1870. View: Masonry-lined passage-way leading to the mill at the center of its circular masonry enclosure. The passageway permitted cane to be carried to the mill and cane trash (bagasse) to be carried away. Bridges over the passageways, no longer in place, permitted the mill animals to circle and power the mill from above. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI
A comparison of fit of CNC-milled titanium and zirconia frameworks to implants.
Abduo, Jaafar; Lyons, Karl; Waddell, Neil; Bennani, Vincent; Swain, Michael
2012-05-01
Computer numeric controlled (CNC) milling was proven to be predictable method to fabricate accurately fitting implant titanium frameworks. However, no data are available regarding the fit of CNC-milled implant zirconia frameworks. To compare the precision of fit of implant frameworks milled from titanium and zirconia and relate it to peri-implant strain development after framework fixation. A partially edentulous epoxy resin models received two Branemark implants in the areas of the lower left second premolar and second molar. From this model, 10 identical frameworks were fabricated by mean of CNC milling. Half of them were made from titanium and the other half from zirconia. Strain gauges were mounted close to the implants to qualitatively and quantitatively assess strain development as a result of framework fitting. In addition, the fit of the framework implant interface was measured using an optical microscope, when only one screw was tightened (passive fit) and when all screws were tightened (vertical fit). The data was statistically analyzed using the Mann-Whitney test. All frameworks produced measurable amounts of peri-implant strain. The zirconia frameworks produced significantly less strain than titanium. Combining the qualitative and quantitative information indicates that the implants were under vertical displacement rather than horizontal. The vertical fit was similar for zirconia (3.7 µm) and titanium (3.6 µm) frameworks; however, the zirconia frameworks exhibited a significantly finer passive fit (5.5 µm) than titanium frameworks (13.6 µm). CNC milling produced zirconia and titanium frameworks with high accuracy. The difference between the two materials in terms of fit is expected to be of minimal clinical significance. The strain developed around the implants was more related to the framework fit rather than framework material. © 2011 Wiley Periodicals, Inc.
Rigol, Anna; Latorre, Anna; Lacorte, Sílvia; Barceló, Damià
2004-02-01
The risk associated with wood extractives, biocides, and other additives in pulp and paper mill effluents was evaluated by performing a characterization of process waters and effluents in terms of toxicity and chemical analysis. The individual toxicity of 10 resin acids, two unsaturated fatty acids, and three biocides was estimated by measuring the bioluminescence inhibition with a ToxAlert 100 system. Median effective concentration values (EC50) of 4.3 to 17.9, 1.2 to 1.5, and 0.022 to 0.50 mg/L were obtained, respectively. Mixtures of these three families of compounds showed antagonistic effects. Chemical analysis of process waters was performed by liquid chromatography- and gas chromatography-mass spectrometry. Biocides such as 2-(thiocyanomethylthio)-benzotiazole (TCMTB) (EC50 = 0.022 mg/L) and 2,2-dibromo-3-nitrilpropionamide (DBNPA) (EC50 = 0.50 mg/L) were the most toxic compounds tested and were detected at concentrations of 16 and 59 microg/L, respectively, in a closed-circuit recycling paper mill. Process waters from kraft pulp mills, printing paper mills, and packing board paper mills showed the highest concentration of resin acids (up to 400 microg/L) and accounted for inhibition percentages up to 100%. Detergent degradation products such as nonylphenol (NP) and octylphenol (OP) and the plasticizer bisphenol A (BPA) were also detected in the waters at levels of 0.6 to 10.6, 0.3 to 1.4, and 0.7 to 187 microg/L, respectively. However, once these waters were biologically treated, the concentration of detected organic compounds diminished and the toxicity decreased in most cases to values of inhibition lower than 20%.
Pasali, Baris; Sarac, Duygu; Kaleli, Necati; Sarac, Yakup Sinasi
2018-02-01
Recently, presintered metal blocks for nonprecious and precious metal implant-supported restorations have gained popularity in computer-aided design and computer-aided manufacturing (CAD-CAM) systems. However, few studies have evaluated the marginal discrepancy of implant-supported restorations made with these new alloy systems. The purpose of this in vitro study was to compare the milling-sintering method with the lost-wax and milling methods in terms of the marginal fit of implant-supported metal-ceramic restorations. Thirty implant abutments screwed to implant analogs were embedded into acrylic resin to investigate marginal fit and then divided according to fabrication methods into the following 3 groups (n=10): lost-wax (LW; control group), milling (M), and milling-sintering (MS). Porcelain material was applied to all specimens after completion of the fabrication process. Subsequently, all specimens were cemented to implant abutments for the measurement of marginal discrepancies. Twelve marginal discrepancy measurements were recorded on each implant abutment by using a stereomicroscope. The arithmetic mean of these 12 measurements was considered the mean marginal discrepancy value of each abutment. Data were statistically analyzed by using 1-way ANOVA and Tukey honest significant difference tests (α=.05). The lowest mean marginal discrepancy values (81 ±2 μm) were observed in the M group, which was significantly different (P<.001) from the other methods. The highest mean marginal discrepancy values (99 ±2 μm) were observed in the MS group. The results revealed that restorations prepared by the milling-sintering method provided clinically acceptable results (<120 μm); however, this new technique was not found to be as precise as the milling method in terms of marginal fit. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Effect of CNC-milling on the marginal and internal fit of dental ceramics: a pilot study.
Schaefer, Oliver; Kuepper, Harald; Thompson, Geoffrey A; Cachovan, Georg; Hefti, Arthur F; Guentsch, Arndt
2013-08-01
Machined restorations have been investigated for their preciseness before, while detailed information on the milling-step itself are lacking. Therefore, the aim of this laboratory study was to quantify the effect of a novel milling-procedure on the marginal and internal fit of ceramic restorations. An acrylic model of a lower left first molar was prepared to receive a ceramic partial crown and was duplicated by one step dual viscosity impressions. Gypsum casts were formed and laser-scanned to realize virtual datasets, before restorations were designed, exported (PRE) and machined from lithium disilicate blanks. Crowns were digitized by a structure-light-scanner to obtain post-milling-data (POST). PRE and POST were virtually superimposed on the reference tooth and subjected to computer-aided-inspection. Visual fit-discrepancies were displayed with colors, while root mean square deviations (RMSD) and degrees of similarity (DS) were computed and analysed by t-tests for paired samples (n=5, α=0.05). The milling procedure resulted in a small increase of the marginal and internal fit discrepancies (RMSD mean: 3μm and 6μm, respectively). RMSD differences were not statistically significant (p=0.495 and p=0.160 for marginal and internal fit, respectively). These results were supported by the DS data. The products of digital dental workflows are prone to imprecisions. However, the present findings suggest that differences between computer-aided designed and actually milled restorations are small, especially when compared to typical fit discrepancies observed clinically. Imprecisions introduced by digital design or production processes are small. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Mauchauffee, S; Denieul, M-P; Coste, M
2012-01-01
Paper mill, chemistry, textile and food processing industries are high water consumers. Within the framework of the European project Aquafit4Use, the possibility to close the on-site water loop is studied. The aim is to find new technologies or innovative treatment trains to produce water that is 'fit for use' in the industrial process; an example of a paper mill is given. Laboratory-scale tests on nine technologies were carried out to determine the best suitable treatment train: anaerobic process (already on site) --> aerobic process (already on site) --> Flexible Fibre Filter Module --> softening --> nanofiltration --> evapoconcentration or ozonation on nanofiltration (NF) concentrate. This treatment train is currently compared on site at pilot scale to another treatment train including some modifications on the existing on-site biological treatment: anaerobic process --> softening --> membrane bioreactor --> nanofiltration --> evapoconcentration or ozonation of NF concentrate.
NASA Astrophysics Data System (ADS)
Martini, Elisabetta; Tomassetti, Mauro; Campanella, Luigi; Fortuna, Antonio
2013-12-01
Photocatalytic technique had already been employed in the treatment of olive mill wastewater (OMW) using the photocatalysis in suspension. The coupling of photocatalytic and membrane techniques should result in a very powerful process bringing great innovation to OMW depollution. Despite the potential advantages using these hybrid photoreactors, research on the combined use of photocatalysis and membranes has so far not been sufficiently developed. The present paper describes a study to assess the photocatalytic efficacy of a new ceramic membrane containing titanium dioxide, irradiated by UV light, used to abate the pollutant load of olive mill wastewater. Good results were obtained (more than 90% of the phenol content was removed and the COD decrease was of the order of 46-51 % in 24 h) particularly using the ceramic membrane compared with those offered by analogous catalytic membranes made of metallic or polymeric materials.
Chowdhary, Ramesh; Jimbo, Ryo; Thomsen, Christian; Carlsson, Lennart; Wennerberg, Ann
2013-03-01
To investigate the combined effect of macro and pitch shortened threads on primary and secondary stability during healing, but before dynamic loading. Two sets of turned implants with different macro geometry were prepared. The test group possessed pitch shortened threads in between the large threads and the control group did not have thread alterations. The two implant groups were placed in both femur and tibiae of 10 lop-eared rabbits, and at the time of implant insertion, insertion torques were recorded. After 4 weeks, all implants were subjected to removal torque tests. The insertion torque values for the control and test groups for the tibia were 15.7 and 20.6 Ncm, respectively, and for the femur, 11.8, and 12.8 Ncm respectively. The removal torque values for the control and test groups in the tibia were 7.9 and 9.1 Ncm, respectively, and for the femur, 7.9 and 7.7 Ncm respectively. There was no statistically significant difference between the control and test groups. Under limited dynamic load, the addition of pitch shortened threads did not significantly improve either the primary or the secondary stability of the implants in bone. © 2011 John Wiley & Sons A/S.
Microstructural investigations of the trimmed edge of DP980 steel sheets
NASA Astrophysics Data System (ADS)
Bhattacharya, S.; Green, D. E.; Sohmshetty, R.; Alpas, A. T.
2017-10-01
In order to reduce vehicle weight while maintaining crashworthiness, advanced high strength steels (AHSSs), such as DP980, are extensively used for manufacturing automotive body components. During trimming operations, the high tensile strength of DP980 sheets tends to cause damage of the trim edge of D2 die inserts, which result in deterioration of the edge quality. The objective of this work is to study the damage microstructures at the trimmed edge of DP980 steel sheets as a function of the number of trimming cycles. A mechanical press equipped with AISI D2 tool steel inserts was used to continuously trim 1.4 mm thick sheets of DP980 at a rate of 30 strokes/min. Cross-sectional SEM images of the trimmed edges revealed that the sheared edge quality of the DP980 sheets decreased, indicated by an increase in the burr width, with an increase in the number of trims from 40,000 to 70,000. Plastic strains were estimated using the displacements of the martensite plates within plastic flow fields of ferrite. Site-specific cross-sectional TEM samples, excised from the trimmed edge using the in-situ `lift-out' technique by focused ion-beam (FIB)-milling, revealed cracking at the ferrite/martensite interfaces after 70,000 cycles indicating an increase in the depth of deformation zone possibly due to trimming with a chipped and blunted die edge.
Omidvari, Negar; Topping, Geoffrey; Cabello, Jorge; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I
2018-05-01
Compromises in the design of a positron emission tomography (PET) insert for a magnetic resonance imaging (MRI) system should minimize the deterioration of image quality in both modalities, particularly when simultaneous demanding acquisitions are performed. In this work, the advantages of using individually read-out crystals with high-gain silicon photomultipliers (SiPMs) were studied with a small animal PET insert for a 7 T MRI system, in which the SiPM charge was transferred to outside the MRI scanner using coaxial cables. The interferences between the two systems were studied with three radio-frequency (RF) coil configurations. The effects of PET on the static magnetic field, flip angle distribution, RF noise, and image quality of various MRI sequences (gradient echo, spin echo, and echo planar imaging (EPI) at 1 H frequency, and chemical shift imaging at 13 C frequency) were investigated. The effects of fast-switching gradient fields and RF pulses on PET count rate were studied, while the PET insert and the readout electronics were not shielded. Operating the insert inside a 1 H volume coil, used for RF transmission and reception, limited the MRI to T1-weighted imaging, due to coil detuning and RF attenuation, and resulted in significant PET count loss. Using a surface receive coil allowed all tested MR sequences to be used with the insert, with 45-59% signal-to-noise ratio (SNR) degradation, compared to without PET. With a 1 H/ 13 C volume coil inside the insert and shielded by a copper tube, the SNR degradation was limited to 23-30% with all tested sequences. The insert did not introduce any discernible distortions into images of two tested EPI sequences. Use of truncated sinc shaped RF excitation pulses and gradient field switching had negligible effects on PET count rate. However, PET count rate was substantially affected by high-power RF block pulses and temperature variations due to high gradient duty cycles.
Solid Rocket Booster Hydraulic Pump Port Cap Joint Load Testing
NASA Technical Reports Server (NTRS)
Gamwell, W. R.; Murphy, N. C.
2004-01-01
The solid rocket booster uses hydraulic pumps fabricated from cast C355 aluminum alloy, with 17-4 PH stainless steel pump port caps. Corrosion-resistant steel, MS51830 CA204L self-locking screw thread inserts are installed into C355 pump housings, with A286 stainless steel fasteners installed into the insert to secure the pump port cap to the housing. In the past, pump port cap fasteners were installed to a torque of 33 Nm (300 in-lb). However, the structural analyses used a significantly higher nut factor than indicated during tests conducted by Boeing Space Systems. When the torque values were reassessed using Boeing's nut factor, the fastener preload had a factor of safety of less than 1, with potential for overloading the joint. This paper describes how behavior was determined for a preloaded joint with a steel bolt threaded into steel inserts in aluminum parts. Finite element models were compared with test results. For all initial bolt preloads, bolt loads increased as external applied loads increased. For higher initial bolt preloads, less load was transferred into the bolt, due to external applied loading. Lower torque limits were established for pump port cap fasteners and additional limits were placed on insert axial deformation under operating conditions after seating the insert with an initial preload.
Karoly, William J; Flatley, John J; Stevenson, Ralph D; Bowers, John D
2004-12-01
Air monitoring data were collected from industrial hygiene surveys over an 8-year period in oriented strand board (OSB) mills. Personal samples were taken to evaluate potential employee exposures to MDI. Area samples were taken to determine the effectiveness of control measures used in the mills to prevent fugitive emissions of wood dust, MDI, and MDI-coated wood dust from the OSB manufacturing process. Personal sampling results (578 samples covering 11 different job categories) ranged from 0.0002-0.524 mg/m3, with a GM = 0.001 and GSD = 3.71. Area sampling results (1657 samples covering 14 stationary locations in the mills) ranged from 0.0002-2.5 mg/m3, with a GM = 0.004 and GSD = 5.52. The statistical range of the data suggests high variability. While exposures to MDI above the established limits (0.051 mg/m3, 8-hour time-weighted average, 0.2 mg/m3, ceiling) can and do occur when engineering controls are not maintained and/or proper work practices and personal protective equipment are not followed/used for certain high exposure potential tasks, the data indicate that over 97% of the personal and 92% of the area sampling results are less than 0.051 mg/m3. Wipe testing was performed to determine the presence of removable, unreacted diisocyanates (NCO functional groups)from various surfaces. Positive results were found in about 13% of the wipe tests on surfaces confined to the blender, forming line, and hopper deck process areas.
Forgie, Marie M; Greer, Danielle M; Kram, Jessica J F; Vander Wyst, Kiley B; Salvo, Nicole P; Siddiqui, Danish S
2016-03-01
Foley catheters are used for cervical ripening during induction of labor. Previous studies suggest that use of a stylette (a thin, rigid wire) to guide catheter insertion decreases insertion failure. However, stylette effects on insertion outcomes have been sparsely studied. The purpose of this study was to compare catheter insertion times, patient-assessed pain levels, and insertion failure rates between women who received a digitally placed Foley catheter for cervical ripening with the aid of a stylette and women who received the catheter without a stylette. We conducted a randomized clinical trial of women aged ≥ 18 years who presented for induction of labor. Inclusion criteria were singletons with intact membranes and cephalic presentation. Women received a computer-generated random assignment of a Foley catheter insertion with a stylette (treatment group, n = 62) or without a stylette (control group, n = 61). For all women, a standard insertion technique protocol was used. Three primary outcomes were of interest, including the following: (1) insertion time (total minutes to successful catheter placement), (2) patient-assessed pain level (0-10), and (3) failure rate of the randomly assigned insertion method. Treatment control differences were first examined using the Pearson's test of independence and the Student t test. Per outcome, we also constructed 4 regression models, each including the random effect of physician and fixed effects of stylette use with patient nulliparity, a history of vaginal delivery, cervical dilation at presentation, or postgraduate year of the performing resident physician. Women who received the Foley catheter with the stylette vs without the stylette did not differ by age, race/ethnicity, body mass index, or any of several other characteristics. Regression models revealed that insertion time, patient pain, and insertion failure were unrelated to stylette use, nulliparity, and history of vaginal delivery. However, overall insertion time and failure were significantly influenced by cervical dilation, with insertion time decreasing by 21% (95% confidence interval [CI], 5-34%) and odds of failure decreasing by 71% (odds ratio, 0.29; 95% CI, 0.10-0.86) per 1 cm dilation. Resident postgraduate year also significantly influenced insertion time, with greater time required of physicians with less experience. Mean insertion time was 51% (95% CI, 23-69%) shorter for fourth-year than second-year residents. Statistically nonsignificant but prominent patterns in outcomes were also observed, suggesting stylette use may lengthen the overall insertion procedure but minimize variability in pain levels and decrease insertion failure. The randomized trial suggests that, even after accounting for nulliparity, history of vaginal delivery, cervical dilation, and physician experience, Foley catheter insertions with and without a stylette are equivalent in insertion times, patient pain levels, and failure of catheter placement. Copyright © 2016 Elsevier Inc. All rights reserved.
Grain characterization and milling behaviour of near-isogenic lines differing by hardness.
Greffeuille, V; Abecassis, J; Rousset, M; Oury, F-X; Faye, A; L'Helgouac'h, C Bar; Lullien-Pellerin, V
2006-12-01
Wheat grain hardness is a major factor affecting the milling behaviour and end-product quality although its exact structural and biochemical basis is still not understood. This study describes the development of new near-isogenic lines selected on hardness. Hard and soft sister lines were characterised by near infrared reflectance (NIR) and particle size index (PSI) hardness index, grain protein content, thousand kernel weight and vitreousness. The milling behaviour of these wheat lines was evaluated on an instrumented micromill which also measures the grinding energy and flour particle size distribution was investigated by laser diffraction. Endosperm mechanical properties were measured using compression tests. Results pointed out the respective effect of hardness and vitreousness on those characteristics. Hardness was shown to influence both the mode of fracture and the mechanical properties of the whole grain and endosperm. Thus, this parameter also acts on milling behaviour. On the other hand, vitreousness was found to mainly play a role on the energy required to break the grain. This study allows us to distinguish between consequences of hardness and vitreousness. Hardness is suggested to influence the adhesion forces between starch granules and protein matrix whereas vitreousness would rather be related to the endosperm microstructure.
Field-scale investigation of pulverized coal mill power consumption
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ganguli, R.; Bandopadhyay, S.
2008-08-15
Twenty field-scale tests were conducted in a 28 MW pulverized coal power plant in Healy, Alaska, to examine mill power consumption in relation to coal grind size. The intent in this field-scale study was to verify if grind size truly impacted power consumption by a detectable amount. The regression model developed from the data indicates that grind size does impact mill power consumption, with finer grinds consuming significantly more power than coarser grinds. However, other factors such as coal hardness (i.e. the lower the Hardgrove Grindability Index, or the harder the coal, the higher the power consumption) and mill throughputmore » (i.e., the higher the throughput, the higher the power consumption) had to be included before the impact of grind size could be isolated. It was also observed that combining amperage and flow rate into a single parameter, i.e., specific amperage, hurt modeling. Cost analysis based on the regression model indicate a power savings of $19,972 per year if the coal were ground to 50% passing 76 {mu}m rather than the industry standard of 70% passing 76 {mu}m. The study also demonstrated that size reduction constituted a significant portion of the power consumption.« less
Mandryk, J; Alwis, K U; Hocking, A D
1999-05-01
Four sawmills, a wood chipping mill, and five joineries in New South Wales, Australia, were studied for the effects of personal exposure to wood dust, endotoxins. (1-->3)-beta-D-glucans, Gram-negative bacteria, and fungi on lung function among woodworkers. Personal inhalable and respirable dust sampling was carried out. The lung function tests of workers were conducted before and after a workshift. The mean percentage cross-shift decrease in lung function was markedly high for woodworkers compared with the controls. Dose-response relationships among personal exposures and percentage cross-shift decrease in lung function and percentage predicted lung function were more pronounced among joinery workers compared with sawmill and chip mill workers. Woodworkers had markedly high prevalence of regular cough, phlegm, and chronic bronchitis compared with controls. Significant associations were found between percentage cross-shift decrease in FVC and regular phlegm and blocked nose among sawmill and chip mill workers. Both joinery workers and sawmill and chip mill workers showed significant relationships between percentage predicted lung function (FVC, FEV1, FEV1/FVC, FEF25-75%) and respiratory symptoms. Wood dust and biohazards associated with wood dust are potential health hazards and should be controlled.
Adsorption of trimethyltin, arsenic and zinc by palm oil mill sludge biochar prepared by microwave
NASA Astrophysics Data System (ADS)
Lam, Goh Ching; Sum, Klinsmann Ng Weng; Bashir, M. J. K.; Sethupathi, Sumathi
2017-04-01
Palm oil mill sludge (POS) is a type of solid left over after anaerobic digestion of palm oil mill effluent. At present, not much work has been reported in the literature on the feasibility of reutilizing this waste. In this study, biochar was prepared from POS. POS was pyrolyzed using microwave technique. Several types of palm oil mill sludge biochar (POSB) was produced by varying the microwave heating power from 100 W to 500 W and the pyrolysis holding time from 5 min to 25 min. The efficiency of the produced POSB was tested for Trimethyltin (TMT), arsenate (As), and zinc (Zn) adsorption capacity. The results of this study highlighted that POSB is able to adsorb Zn by the functional groups. The adsorption capacity of Zn was recorded as 44.5 mg/g. However, for TMT and As, the adsorption was very minimum i.e. about 3.3 mg/g and 5.6 mg/g respectively. It was suggested that poor performance of POSB was due to the anionic nature of TMT and As. It was concluded that microwave pyrolysis was not suitable for POSB preparation.
End Restraints for Impact-Energy-Absorbing Tube Specimens
NASA Technical Reports Server (NTRS)
Farley, G. L.; Modlin, J. T.
1985-01-01
Inexpensive device developed that eliminates tipping problem without affecting crushing process. Device consists of soft sponge-rubber insert approximately 0.5 inches (1.3 centimeters) thick, cut to same diameter as internal diameter of tube specimen. Metal washer, slightly smaller than internal diameter of tube, placed on top of rubber insert. Screw passed through washer and rubber insert and threaded into base of test machine. As screw tightened against washer, rubber insert compressed and expands radially. Radial expansion applies pressure against internal wall of tube specimen, which provides sufficient support to tube to prevent tipping.
Evaluation of waveguide coating materials
NASA Technical Reports Server (NTRS)
Chen, W. C. J.; Baker, B. W.
1982-01-01
Waveguide coating materials were tested at 8470 MHz for insertion loss. Samples of these coatings on waveguide pieces without flanges were tested in an environmental chamber to simulate the effects of high power microwave heating. Test results indicated that three types of coating materials are acceptable with regard to insertion loss. However, simulated microwave heating caused debonding of Metcot 7 and BD-991 coatings, resulting in peelings in the waveguide. The higher cost Chemglaze R104 does not exhibit this problem.
Subleading Regge limit from a soft anomalous dimension
NASA Astrophysics Data System (ADS)
Brüser, Robin; Caron-Huot, Simon; Henn, Johannes M.
2018-04-01
Wilson lines capture important features of scattering amplitudes, for example soft effects relevant for infrared divergences, and the Regge limit. Beyond the leading power approximation, corrections to the eikonal picture have to be taken into account. In this paper, we study such corrections in a model of massive scattering amplitudes in N=4 super Yang-Mills, in the planar limit, where the mass is generated through a Higgs mechanism. Using known three-loop analytic expressions for the scattering amplitude, we find that the first power suppressed term has a very simple form, equal to a single power law. We propose that its exponent is governed by the anomalous dimension of a Wilson loop with a scalar inserted at the cusp, and we provide perturbative evidence for this proposal. We also analyze other limits of the amplitude and conjecture an exact formula for a total cross-section at high energies.
Donaldson-Witten theory and indefinite theta functions
NASA Astrophysics Data System (ADS)
Korpas, Georgios; Manschot, Jan
2017-11-01
We consider partition functions with insertions of surface operators of topologically twisted N=2 , SU(2) supersymmetric Yang-Mills theory, or Donaldson-Witten theory for short, on a four-manifold. If the metric of the compact four-manifold has positive scalar curvature, Moore and Witten have shown that the partition function is completely determined by the integral over the Coulomb branch parameter a, while more generally the Coulomb branch integral captures the wall-crossing behavior of both Donaldson polynomials and Seiberg-Witten invariants. We show that after addition of a \\overlineQ -exact surface operator to the Moore-Witten integrand, the integrand can be written as a total derivative to the anti-holomorphic coordinate ā using Zwegers' indefinite theta functions. In this way, we reproduce Göttsche's expressions for Donaldson invariants of rational surfaces in terms of indefinite theta functions for any choice of metric.
NASA Technical Reports Server (NTRS)
Whittenberger, J. D.; Moore, T. J.
1977-01-01
A study of the flow strength, creep resistance and diffusion welding characteristics of the titanium alloy Ti-6Al-2Nb-1Ta-0.8Mo was conducted. Two mill-processed forms of this alloy were examined. The forged material was essentially processed above the beta transus while the rolled form was subjected to considerable work below the beta transus. Between 1150 and 1250 K, the forged material was stronger and more creep resistant than the rolled alloy. Both forms exhibit superplastic characteristics in this temperature range. Strain measurements during diffusion welding experiments at 1200 K reveal that weld interfaces have no measurable effect on the overall creep deformation. Significant deformation appears to be necessary to produce a quality diffusion weld between superplastic materials. A 'soft' interlayer inserted between faying surfaces would seemingly allow manufacture of quality diffusion welds with little overall deformation.
Performance of CAD/CAM fabricated fiber posts in oval-shaped root canals: An in vitro study.
Tsintsadze, Nino; Juloski, Jelena; Carrabba, Michele; Tricarico, Marella; Goracci, Cecilia; Vichi, Alessandro; Ferrari, Marco; Grandini, Simone
2017-10-01
To assess the push-out strength, the cement layer thickness and the interfacial nanoleakage of prefabricated fiber posts, CAD/CAM fiber posts and metal cast posts cemented into oval-shaped root canals. Oval-shaped post spaces were prepared in 30 single-rooted premolars. Roots were randomly assigned to three groups (n=10), according to the post type to be inserted: Group 1: Prefabricated fiber post (D.T. Light-Post X-RO Illusion); Group 2: Cast metal post; Group 3: CAD/CAM-fabricated fiber post (experimental fiber blocks). In Group 3, post spaces were sprayed with scan powder (VITA), scanned with an inEos 4.2 scanner, and fiber posts were milled using an inLab MC XL CAD/CAM milling unit. All posts were cemented using Gradia Core dual-cure resin cement in combination with Gradia core self-etching bond (GC). After 24 hours, the specimens were sectioned perpendicular to the long axis into six 1 mm-thick sections, which were differentiated by the root level. Sections from six roots per group were used to measure the cement thickness and subsequently for the thin-slice push-out test, whereas the sections from the remaining four teeth were assigned to interfacial nanoleakage test. The cement thickness around the posts was measured in micrometers (µm) on the digital images acquired with a digital microscope using the Digimizer software. Thin-slice push-out test was conducted using a universal testing machine at the crosshead speed of 0.5 mm/minute and the bond strength was expressed in megaPascals (MPa). The interfacial nanoleakage was observed under light microscope and quantified by scoring the depth of silver nitrate penetration along the post-cement-dentin interfaces. The obtained results were statistically analyzed by Kruskal-Wallis ANOVA, followed by the Dunn's Multiple Range test for post hoc comparisons. The level of significance was set at P< 0.05. Statistically significant differences were found among the groups in push-out bond strength, cement thickness and interfacial nanoleakage (P< 0.05). CAD/CAM-fabricated fiber posts achieved retention that was comparable to that of cast metal posts and significantly higher than that of prefabricated fiber posts. The cement layer thickness around CAD/CAM-fabricated fiber posts was significantly lower than around prefabricated fiber posts, but higher than that around cast metal posts. Root level was not a significant factor for push-out strength in any of the groups, whereas it significantly affected cement layer thickness only in the prefabricated fiber post group. No differences were observed in interfacial nanoleakage between CAD/CAM fabricated and prefabricated fiber posts, while nanoleakage recorded in cast metal posts was significantly lower. CAD/CAM fabricated fiber posts could represent a valid alternative to traditionally used posts in the restoration of endodontically-treated teeth with oval or wide root canals, offering the advantages of better esthetics, retention, and cement thickness values that are comparable to cast post and cores.
Edgeless composite laminate specimen for static and fatigue testing
NASA Technical Reports Server (NTRS)
Liber, T.; Daniel, I. M.
1978-01-01
The influence of edge effects on the tensile properties of angle-ply laminate composites can be eliminated by using edgeless (round tubular) specimens. However, uniaxial tests with such specimens, static and fatigue, have been generally unsuccessful because of the differential Poisson effect between the test section and the grips. An edgeless cylindrical specimen, developed to circumvent these difficulties, is examined in the present paper. It is a flattened tube consisting of two flat sides connected by curved sections. It can be handled much like the standard flat coupon. The flat ends of the specimen are provided with crossplied fiberglass gripping tabs, the same as used for flat test coupons. As part of the tabbing, the hollow ends must be plugged with inserts to prevent crushing of the ends. A special insert design was developed to minimize detrimental Poisson effects ordinarily introduced by inserts.
Thermodynamics of membrane insertion and refolding of the diphtheria toxin T-domain
Vargas-Uribe, Mauricio; Rodnin, Mykola V.; Öjemalm, Karin; Holgado, Aurora; Kyrychenko, Alexander; Nilsson, IngMarie; Posokhov, Yevgen O.; Makhatadze, George; von Heijne, Gunnar; Ladokhin, Alexey S.
2014-01-01
The diphtheria toxin translocation (T) domain inserts into the endosomal membrane in response to the endosomal acidification and enables the delivery of the catalytic domain into the cell. The insertion pathway consists of a series of conformational changes that occur in solution and in the membrane and leads to the conversion of a water-soluble state into a transmembrane state. In this work, we utilize various biophysical techniques to characterize the insertion pathway from the thermodynamic perspective. Thermal and chemical unfolding measured by differential scanning calorimetry, circular dichroism and tryptophan fluorescence reveal that the free energy of unfolding of the T-domain at neutral and mildly acidic pH differ by 3–5 kcal/mol, depending on the experimental conditions. Fluorescence correlation spectroscopy measurements show that the free energy change from the membrane-competent state to the interfacial state is approximately −8 kcal/mol and is pH-independent, while that from the membrane-competent state to the transmembrane state ranges between −9.5 to −12 kcal/mol, depending on the membrane lipid composition and pH. Finally, the thermodynamics of transmembrane insertion of individual helices was tested using an in vitro assay that measures the translocon-assisted integration of test sequences into the microsomal membrane. These experiments suggest that even the most hydrophobic helix TH8 has only a small favorable free energy of insertion. The free energy for the insertion of the consensus insertion unit TH8-TH9 is slightly more favorable, yet less favorable than that measured for the entire protein, suggesting a cooperative effect for the membrane insertion of the helices of the T-domain. PMID:25281329
12. TROJAN MILL, INTERIOR SHOWING PRIMARY MILL No. 1 (MONADNOCK ...
12. TROJAN MILL, INTERIOR SHOWING PRIMARY MILL No. 1 (MONADNOCK CHILEAN) FROM EAST, c. 1912. ELEVATOR No. 1 ADJACENT TO MILL. CREDIT WR. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD
1964-09-19
XV-5A airplane installed in 40x80ft Subsonic Wind Tunnel at NASA Ames Research Center with Tom Mills. The propulsive lift system was tested to determine power-on performance characteristics in preparation for flight tests. Used in Memoiors of an Aeronautical Engineer, Flight Tests at Ames Research Center 1940-1970 NASA-SP-2002-4526 (Seth B. Anderson)
Turbine Airfoil With CMC Leading-Edge Concept Tested Under Simulated Gas Turbine Conditions
NASA Technical Reports Server (NTRS)
Robinson, R. Craig; Hatton, Kenneth S.
2000-01-01
Silicon-based ceramics have been proposed as component materials for gas turbine engine hot-sections. When the Navy s Harrier fighter experienced engine (Pegasus F402) failure because of leading-edge durability problems on the second-stage high-pressure turbine vane, the Office of Naval Research came to the NASA Glenn Research Center at Lewis Field for test support in evaluating a concept for eliminating the vane-edge degradation. The High Pressure Burner Rig (HPBR) was selected for testing since it could provide temperature, pressure, velocity, and combustion gas compositions that closely simulate the engine environment. The study focused on equipping the stationary metal airfoil (Pegasus F402) with a ceramic matrix composite (CMC) leading-edge insert and evaluating the feasibility and benefits of such a configuration. The test exposed the component, with and without the CMC insert, to the harsh engine environment in an unloaded condition, with cooling to provide temperature relief to the metal blade underneath. The insert was made using an AlliedSignal Composites, Inc., enhanced HiNicalon (Nippon Carbon Co. LTD., Yokohama, Japan) fiber-reinforced silicon carbide composite (SiC/SiC CMC) material fabricated via chemical vapor infiltration. This insert was 45-mils thick and occupied a recessed area in the leading edge and shroud of the vane. It was designed to be free floating with an end cap design. The HPBR tests provided a comparative evaluation of the temperature response and leading-edge durability and included cycling the airfoils between simulated idle, lift, and cruise flight conditions. In addition, the airfoils were aircooled, uniquely instrumented, and exposed to the exact set of internal and external conditions, which included gas temperatures in excess of 1370 C (2500 F). In addition to documenting the temperature response of the metal vane for comparison with the CMC, a demonstration of improved leading-edge durability was a primary goal. First, the metal vane was tested for a total of 150 cycles. Both the leading edge and trailing edge of the blade exhibited fatigue cracking and burn-through similar to the failures experienced in service by the F402 engine. Next, an airfoil, fitted with the ceramic leading edge insert, was exposed for 200 cycles. The temperature response of those HPBR cycles indicated a reduced internal metal temperature, by as much as 600 F at the midspan location for the same surface temperature (2100 F). After testing, the composite insert appeared intact, with no signs of failure on either the vane s leading or trailing edge. Only a slight oxide scale, as would be expected, was noted on the insert. Overall, the CMC insert performed similarly to a thick thermal barrier coating. With a small air gap between the metal and the SiC/SiC leading edge, heat transfer from the CMC to the metal alloy was low, effectively lowering the temperatures. The insert's performance has proven that an uncooled CMC can be engineered and designed to withstand the thermal up-shock experienced during the severe lift conditions in the Pegasus engine. The design of the leading-edge insert, which minimized thermal stresses in the SiC/SiC CMC, showed that the CMC/metal assembly can be engineered to be a functioning component.
12. RW Meyer Sugar Mill: 18761889. Threeroll sugar mill: oneton ...
12. RW Meyer Sugar Mill: 1876-1889. Three-roll sugar mill: one-ton daily processing capacity. Manufactured by Edwin Maw, Liverpool, England, ca. 1855-1870. View: Historical view, 1934, T.T. Waterman Collection, Hawaiian Sugar Planters' Association, Oahu, Hawaii. Masonry-lined passageway leading to the mill at the center of its circular masonry enclosure. The passageway permitted cane to be carried to the mill and cane trash (bagasse) to be carried away after milling. Bridges over the passageways, not in place, permitted the mill animals to circle and power the mill from above. View shows area prior to substantial overgrowth existing in 1978 views of the area. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI
Galindo-González, Leonardo; Mhiri, Corinne; Grandbastien, Marie-Angèle; Deyholos, Michael K
2016-12-07
Initial characterization of the flax genome showed that Ty1-copia retrotransposons are abundant, with several members being recently inserted, and in close association with genes. Recent insertions indicate a potential for ongoing transpositional activity that can create genomic diversity among accessions, cultivars or varieties. The polymorphisms generated constitute a good source of molecular markers that may be associated with phenotype if the insertions alter gene activity. Flax, where accessions are bred mainly for seed nutritional properties or for fibers, constitutes a good model for studying the relationship of transpositional activity with diversification and breeding. In this study, we estimated copy number and used a type of transposon display known as Sequence-Specific Amplification Polymorphisms (SSAPs), to characterize six families of Ty1-copia elements across 14 flax accessions. Polymorphic insertion sites were sequenced to find insertions that could potentially alter gene expression, and a preliminary test was performed with selected genes bearing transposable element (TE) insertions. Quantification of six families of Ty1-copia elements indicated different abundances among TE families and between flax accessions, which suggested diverse transpositional histories. SSAPs showed a high level of polymorphism in most of the evaluated retrotransposon families, with a trend towards higher levels of polymorphism in low-copy number families. Ty1-copia insertion polymorphisms among cultivars allowed a general distinction between oil and fiber types, and between spring and winter types, demonstrating their utility in diversity studies. Characterization of polymorphic insertions revealed an overwhelming association with genes, with insertions disrupting exons, introns or within 1 kb of coding regions. A preliminary test on the potential transcriptional disruption by TEs of four selected genes evaluated in three different tissues, showed one case of significant impact of the insertion on gene expression. We demonstrated that specific Ty1-copia families have been active since breeding commenced in flax. The retrotransposon-derived polymorphism can be used to separate flax types, and the close association of many insertions with genes defines a good source of potential mutations that could be associated with phenotypic changes, resulting in diversification processes.
13. TROJAN MILL, INTERIOR SHOWING PRIMARY MILL No. 1 (ALLIS ...
13. TROJAN MILL, INTERIOR SHOWING PRIMARY MILL No. 1 (ALLIS CHALMERS BALL MILL) FROM EAST, c. 1919. ELECTRIC MOTOR AND DRIVE SHAFT CLEARLY VISIBLE. CREDIT WR. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD
Psychosocial and health impacts of uranium mining and milling on Navajo lands.
Dawson, Susan E; Madsen, Gary E
2011-11-01
The uranium industry in the American Southwest has had profoundly negative impacts on American Indian communities. Navajo workers experienced significant health problems, including lung cancer and nonmalignant respiratory diseases, and psychosocial problems, such as depression and anxiety. There were four uranium processing mills and approximately 1,200 uranium mines on the Navajo Nation's over 27,000 square miles. In this paper, a chronology is presented of how uranium mining and milling impacted the lives of Navajo workers and their families. Local community leaders organized meetings across the reservation to inform workers and their families about the relationship between worker exposures and possible health problems. A reservation-wide effort resulted in activists working with political leaders and attorneys to write radiation compensation legislation, which was passed in 1990 as the Radiation Exposure Compensation Act (RECA) and included underground uranium miners, atomic downwinders, and nuclear test-site workers. Later efforts resulted in the inclusion of surface miners, ore truck haulers, and millworkers in the RECA Amendments of 2000. On the Navajo Nation, the Office of Navajo Uranium Workers was created to assist workers and their families to apply for RECA funds. Present issues concerning the Navajo and other uranium-impacted groups include those who worked in mining and milling after 1971 and are excluded from RECA. Perceptions about uranium health impacts have contributed recently to the Navajo people rejecting a resumption of uranium mining and milling on Navajo lands.
Facile Fabrication of 100% Bio-Based and Degradable Ternary Cellulose/PHBV/PLA Composites
Wang, Jinwu
2018-01-01
Modifying bio-based degradable polymers such as polylactide (PLA) and poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) with non-degradable agents will compromise the 100% degradability of their resultant composites. This work developed a facile and solvent-free route in order to fabricate 100% bio-based and degradable ternary cellulose/PHBV/PLA composite materials. The effects of ball milling on the physicochemical properties of pulp cellulose fibers, and the ball-milled cellulose particles on the morphology and mechanical properties of PHBV/PLA blends, were investigated experimentally and statistically. The results showed that more ball-milling time resulted in a smaller particle size and lower crystallinity by way of mechanical disintegration. Filling PHBV/PLA blends with the ball-milled celluloses dramatically increased the stiffness at all of the levels of particle size and filling content, and improved their elongation at the break and fracture work at certain levels of particle size and filling content. It was also found that the high filling content of the ball-milled cellulose particles was detrimental to the mechanical properties for the resultant composite materials. The ternary cellulose/PHBV/PLA composite materials have some potential applications, such as in packaging materials and automobile inner decoration parts. Furthermore, filling content contributes more to the variations of their mechanical properties than particle size does. Statistical analysis combined with experimental tests provide a new pathway to quantitatively evaluate the effects of multiple variables on a specific property, and figure out the dominant one for the resultant composite materials. PMID:29495315
Li, Hailiang; Cui, Xiaoli; Tong, Yan; Gong, Muxin
2012-04-01
To compare inclusion effects and process conditions of two preparation methods-colloid mill and saturated solution-for beta-CD inclusion compound of four traditional Chinese medicine volatile oils and study the relationship between each process condition and volatile oil physical properties and the regularity of selective inclusion of volatile oil components. Volatile oils from Nardostachyos Radix et Rhizoma, Amomi Fructus, Zingiberis Rhizoma and Angelicaesinensis Radix were prepared using two methods in the orthogonal test. These inclusion compounds by optimized processes were assessed and compared by such methods as TLC, IR and scanning electron microscope. Inclusion oils were extracted by steam distillation, and the components found before and after inclusion were analyzed by GC-MS. Analysis showed that new inclusion compounds, but inclusion compounds prepared by the two processes had differences to some extent. The colloid mill method showed a better inclusion effect than the saturated solution method, indicating that their process conditions had relations with volatile oil physical properties. There were differences in the inclusion selectivity of components between each other. The colloid mill method for inclusion preparation is more suitable for industrial requirements. To prepare volatile oil inclusion compounds with heavy gravity and high refractive index, the colloid mill method needs longer time and more water, while the saturated solution method requires higher temperature and more beta-cyclodextrin. The inclusion complex prepared with the colloid mill method contains extended molecular weight chemical composition, but the kinds of components are reduced.
Goulet, Richard R; Thompson, Patsy A; Serben, Kerrie C; Eickhoff, Curtis V
2015-01-01
Treated effluent discharge from uranium (U) mines and mills elevates the concentrations of U, calcium (Ca), magnesium (Mg), and sulfate (SO42–) above natural levels in receiving waters. Many investigations on the effect of hardness on U toxicity have been experiments on the combined effects of changes in hardness, pH, and alkalinity, which do not represent water chemistry downstream of U mines and mills. Therefore, more toxicity studies with water chemistry encountered downstream of U mines and mills are necessary to support predictive assessments of impacts of U discharge to the environment. Acute and chronic U toxicity laboratory bioassays were realized with 6 freshwater species in waters of low alkalinity, circumneutral pH, and a range of chemical hardness as found in field samples collected downstream of U mines and mills. In laboratory-tested waters, speciation calculations suggested that free uranyl ion concentrations remained constant despite increasing chemical hardness. When hardness increased while pH remained circumneutral and alkalinity low, U toxicity decreased only to Hyalella azteca and Pseudokirchneriella subcapitata. Also, Ca and Mg did not compete with U for the same uptake sites. The present study confirms that the majority of studies concluding that hardness affected U toxicity were in fact studies in which alkalinity and pH were the stronger influence. The results thus confirm that studies predicting impacts of U downstream of mines and mills should not consider chemical hardness. PMID:25475484
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-13
..., as an Addition to the Bay Mills Indian Reservation for the Bay Mills Indian Community of Michigan..., more or less, to be added to the Bay Mills Indian Reservation for the Bay Mills Indian Community of... Mills Indian Reservation and part of the Bay Mills Indian Community of Michigan for the exclusive use of...
33. RW Meyer Sugar Mill: 18761889. Threeroll sugar mill, oneton ...
33. RW Meyer Sugar Mill: 1876-1889. Three-roll sugar mill, one-ton daily processing capacity. Manufactured by Edwin Maw, Liverpool, England, ca. 1855-1870. View: From above the mill showing the three 15' x 22' horizontal rolls, mill frame or cheeks, portland cement foundation, and lower part of vertical drive shaft lying next mill in foreground. The loose metal piece resting on top of the mill frame matched the indented portion of the upper frame to form a bracket and bearing for the drive shaft when it was in its proper upright position. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI
BIOMECHANICAL EVALUATION OF THE INFLUENCE OF CERVICAL SCREWS TAPPING AND DESIGN.
Silva, Patricia; Rosa, Rodrigo César; Shimano, Antonio Carlos; Albuquerque de Paula, Francisco José; Volpon, José Batista; Aparecido Defino, Helton Luiz
2009-01-01
To assess if the screw design (self-drilling/self-tapping) and the pilot hole tapping could affect the insertion torque and screw pullout strength of the screw used in anterior fixation of the cervical spine. Forty self-tapping screws and 20 self-drilling screws were inserted into 10 models of artificial bone and 10 cervical vertebrae of sheep. The studied parameters were the insertion torque and pullout strength. The following groups were created: Group I-self-tapping screw insertion after pilot hole drilling and tapping; Group II-self-tapping screw insertion after pilot hole drilling without tapping; Group III-self-drilling screw insertion without drilling and tapping. In Groups I and II, the pilot hole had 14.0 mm in depth and was made with a 3mmn drill, while tapping was made with a 4mm tap. The insertion torque was measured and the pullout test was performed. The comparison between groups was made considering the mean insertion torque and the maximum mean pullout strength with the variance analysis (ANOVA; p≤ 0.05). Previous drilling and tapping of pilot hole significantly decreased the insertion torque and the pullout strength. The insertion torque and pullout strength of self-drilling screws were significantly higher when compared to self-tapping screws inserted after pilot hole tapping.
Effects of milling on functional properties of rice flour.
Kadan, R S; Bryant, R J; Miller, J A
2008-05-01
A commercial long-grain rice flour (CRF) and the flours made by using a pin mill and the Udy mill from the same batch of broken second-head white long-grain rice were evaluated for their particle size and functional properties. The purpose of this study was to compare the commercial rice flour milling method to the pin and Udy milling methods used in our laboratory and pilot plant. The results showed that pin milled flour had more uniform particle size than the other 2 milled flours. The chalky kernels found in broken white milled rice were pulverized more into fines in both Udy milled flour and CRF than in the pin milled flour. The excessive amount of fines in flours affected their functional properties, for example, WSI and their potential usage in the novel foods such as rice breads (RB). The RB made from CRF collapsed more than loaves made from pin milled Cypress long-grain flours.
Ocean Engineering Studies Compiled 1991. Volume 9. External Pressure Housing - Conrete
1991-01-01
by inserts of different rigidities would thus be obtained. Table 1. Description of Concrete Sphere Models and Test...relationship between the insert’s rigidity and the strain increase in its vicinity. Planned investigation by NCEL employing photoelastic analysis of models of ... structural , in which only the load -carrying ability of the structure was checked. In the operational tests, the small-scale model habitat
A. Dan Wilson; D.G. Lester
1997-01-01
Second-year field evaluations of four trench insert materials, including water-permeable Typar® polypropylene spunbonded fabric, Biobarrier® or Typar® with trifluralin-impregnated nodules, and water-impermeable polyethylene Geomembrane liners of two thicknesses (20 and 30 mil), were conducted to further test the effectiveness of these physical and/or chemical barriers...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-02-01
This volume contains appendices D6 through D8 containing laboratory test data: from MK-F investigation, 1987, Old Rifle and New Rifle sites; on bentonite amended radon barrier material; and from MK-F investigation, 1987, riprap tests.
42 CFR 84.308 - Additional testing.
Code of Federal Regulations, 2013 CFR
2013-10-01
... §§ 84.304 through 84.307. These units will be evaluated for fire and explosion hazards using the tests....S.C. 552(a) and 1 CFR Part 51. All approved material is available for inspection at NIOSH, National Personal Protection Technology Laboratory (NPPTL), Bruceton Research Center, 626 Cochrans Mill Road...
42 CFR 84.308 - Additional testing.
Code of Federal Regulations, 2014 CFR
2014-10-01
... §§ 84.304 through 84.307. These units will be evaluated for fire and explosion hazards using the tests....S.C. 552(a) and 1 CFR Part 51. All approved material is available for inspection at NIOSH, National Personal Protection Technology Laboratory (NPPTL), Bruceton Research Center, 626 Cochrans Mill Road...
42 CFR 84.308 - Additional testing.
Code of Federal Regulations, 2012 CFR
2012-10-01
... §§ 84.304 through 84.307. These units will be evaluated for fire and explosion hazards using the tests....S.C. 552(a) and 1 CFR Part 51. All approved material is available for inspection at NIOSH, National Personal Protection Technology Laboratory (NPPTL), Bruceton Research Center, 626 Cochrans Mill Road...
Investigation of the milling capabilities of the F10 Fine Grind mill using Box-Behnken designs.
Tan, Bernice Mei Jin; Tay, Justin Yong Soon; Wong, Poh Mun; Chan, Lai Wah; Heng, Paul Wan Sia
2015-01-01
Size reduction or milling of the active is often the first processing step in the design of a dosage form. The ability of a mill to convert coarse crystals into the target size and size distribution efficiently is highly desirable as the quality of the final pharmaceutical product after processing is often still dependent on the dimensional attributes of its component constituents. The F10 Fine Grind mill is a mechanical impact mill designed to produce unimodal mid-size particles by utilizing a single-pass two-stage size reduction process for fine grinding of raw materials needed in secondary processing. Box-Behnken designs were used to investigate the effects of various mill variables (impeller, blower and feeder speeds and screen aperture size) on the milling of coarse crystals. Response variables included the particle size parameters (D10, D50 and D90), span and milling rate. Milled particles in the size range of 5-200 μm, with D50 ranging from 15 to 60 μm, were produced. The impeller and feeder speeds were the most critical factors influencing the particle size and milling rate, respectively. Size distributions of milled particles were better described by their goodness-of-fit to a log-normal distribution (i.e. unimodality) rather than span. Milled particles with symmetrical unimodal distributions were obtained when the screen aperture size was close to the median diameter of coarse particles employed. The capacity for high throughput milling of particles to a mid-size range, which is intermediate between conventional mechanical impact mills and air jet mills, was demonstrated in the F10 mill. Prediction models from the Box-Behnken designs will aid in providing a better guide to the milling process and milled product characteristics. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Gray, H. R.
1971-01-01
The Ti-8Al-1Mo-1V alloy was tested in four conditions: mill annealed (70 ppM H), duplex annealed (70 ppM H), vacuum annealed to an intermediate (36 ppM) and a low (9 ppM H) hydrogen level. Material annealed at 650 C (duplex condition) exhibited resistance to hot-salt stress corrosion superior to that exhibited by material in the mill-annealed condition. Reduction of the alloy hydrogen content from 70 to as low as 9 ppM did not influence resistance to hot-salt stress corrosion embrittlement or cracking.
Optimizing the milling characteristics of Al-SiC particulate composites
NASA Astrophysics Data System (ADS)
Karthikeyan, R.; Raghukandan, K.; Naagarazan, R. S.; Pai, B. C.
2000-12-01
The present investigation focuses on the face milling characteristics of LM25Al-SiC particulate composites produced through stir casting. Experiments were conducted according to an L27 orthogonal array and mathematical models were developed for such machining characteristics as flank wear, specific energy and surface roughness whose adequacy was checked. The insignificant effects present in the models were eliminated using a t-test. Goal programming was employed to optimize the cutting conditions by considering such primary objectives as maximizing the metal removal rate and minimizing tool wear, specific energy and surface roughness.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-23
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-73,695] Woodland Mills Corporation Mill Spring, NC; Notice of Revised Determination on Reconsideration By application dated July 22... regarding the eligibility of workers and former workers of Woodland Mills Corporation, Mill Spring, North...
1. PERSPECTIVE VIEW OF KEX PLANT, FORMER CALLAWAY MILLS UNITY ...
1. PERSPECTIVE VIEW OF KEX PLANT, FORMER CALLAWAY MILLS UNITY COTTON MILL (A. FRANCIS WALKER, 1900-01) FROM DUNSON STREET. UNITY COTTON MILL WAS THE FIRST OF SEVERAL TEXTILE MILLS BUILT BY THE CALLAWAY MILLS GROUP IN SOUTHWEST LAGRANGE DURING THE EARLY TWENTIETH CENTURY. NOTE REMAINING PORTION OF ORIGINAL WATER TANK TOWER IN MIDDLE OF PHOTOGRAPH. - Unity Cotton Mill, 815 Leeman Street, La Grange, Troup County, GA
Multichannel cochlear implantation in the scala vestibuli.
Lin, Karen; Marrinan, Michelle S; Waltzman, Susan B; Roland, J Thomas
2006-08-01
Sensorineural hearing loss resulting from otosclerosis, meningitis, chronic otitis media, autoimmune ear disease, and trauma can be associated with partial or total obstruction of the cochlear scalae. Multichannel cochlear implantation may be difficult in a cochlea with an obstructed scala tympani. The purpose of this study is to determine the safety and efficacy of scala tympani electrode insertion. Retrospective chart review. Academic medical center. Eight children and adults with profound sensorineural hearing loss who underwent cochlear implantation with known scala vestibuli electrode array insertion were subjects for this study. Eight study subjects underwent implantation: five with the Nucleus 24RCS (Contour) device and three with the Nucleus 24M device. Imaging findings, operative findings, and age-appropriate speech perception testing. All patients had full electrode insertion. Various obstructive patterns on computed tomography and magnetic resonance imaging were found, and there was a range of speech perception results. All but one patient improved based on age-appropriate monosyllabic word and sentence tests. Scala vestibuli multielectrode insertion is a viable alternative when scala tympani insertion is not possible because of abnormal anatomy or anatomical changes secondary to disease or previous implantation. We will also present an algorithm of options for decision making for implantation when encountering cochlear obstruction and difficult electrode insertion.
Welding of titanium and stainless steel using the composite insert
NASA Astrophysics Data System (ADS)
Cherepanov, A. N.; Mali, V. I.; Orishich, A. M.; Malikov, A. G.; Drozdov, V. O.; Malyutina, Y. N.
2016-11-01
The paper concerns the possibility of obtaining a lasting permanent joint of dissimilar metals: technically pure titanium and stainless steel using laser welding and an intermediate composite insert. The insert was a four-layer composition of plates of steel, copper, niobium, and titanium welded by explosion. The material layers used in the insert prevented the molten steel and titanium from mixing, which excluded the formation of brittle intermetallic compounds, such as FeTi and Fe2Ti. The optimization of explosion welding parameters provided a high quality of the four-layer composition and the absence of defects in the area of the joint of insert plates. The results of strength tests showed that values of the ultimate strength and yield of the permanent joint with the composite insert welded by explosion are comparable to the strength characteristics of titanium.
NASA Astrophysics Data System (ADS)
Velásquez, A. A.; Marín, C. C.; Urquijo, J. P.
2018-03-01
We present the process of synthesis and characterization of magnetite-maghemite nanoparticles by the ball milling method. The particles were synthesized in a planetary ball mill equipped with vials and balls of tempered steel, employing dry and wet conditions. For dry milling, we employed microstructured analytical-grade hematite (α-Fe2O3), while for wet milling, we mixed hematite and deionized water. Milling products were characterized by X-ray diffraction, transmission electron microscopy, room temperature Mössbauer spectroscopy, vibrating sample magnetometry, and atomic absorption spectroscopy. The Mössbauer spectrum of the dry milling product was well fitted with two sextets of hematite, while the spectrum of the wet milling product was well fitted with three sextets of spinel phase. X-ray measurements confirmed the phases identified by Mössbauer spectroscopy in both milling conditions and a reduction in the crystallinity of the dry milling product. TEM measurements showed that the products of dry milling for 100 h and wet milling for 24 h consist of aggregates of nanoparticles distributed in size, with mean particle size of 10 and 15 nm, respectively. Magnetization measurements of the wet milling product showed little coercivity and a saturation magnetization around 69 emu g-1, characteristic of a nano-spinel system. Atomic absorption measurements showed that the chromium contamination in the wet milling product is approximately two orders of magnitude greater than that found in the dry milling product for 24 h, indicating that the material of the milling bodies, liberated more widely in wet conditions, plays an important role in the conversion hematite-spinel phase.
Synthesis and investigation of novel cathode materials for sodium ion batteries
NASA Astrophysics Data System (ADS)
Sawicki, Monica
Environmental pollution and eventual depletion of fossil fuels and lithium has increased the need for research towards alternative electrical energy storage systems. In this context, research in sodium ion batteries (NIBs) has become more prevalent since the price in lithium has increased due to its demand and reserve location. Sodium is an abundant resource that is low cost, and safe; plus its chemical properties are similar to that of Li which makes the transition into using Na chemistry for ion battery systems feasible. In this study, we report the effects of processing conditions on the electrochemical properties of Na-ion batteries made of the NaCrO2 cathode. NaCrO2 is synthesized via solid state reactions. The as-synthesized powder is then subjected to high-energy ball milling under different conditions which reduces particle size drastically and causes significant degradation of the specific capacity for NaCrO2. X-ray diffraction reveals that lattice distortion has taken place during high-energy ball milling and in turn affects the electrochemical performance of the cathode material. This study shows that a balance between reducing particle size and maintaining the layered structure is essential to obtain high specific capacity for the NaCrO2 cathode. In light of the requirements for grid scale energy storage: ultra-long cycle life (> 20,000 cycles and calendar life of 15 to 20 years), high round trip efficiency (> 90%), low cost, sufficient power capability, and safety; the need for a suitable cathode materials with excellent capacity retention such as Na2MnFe(CN)6 and K2MnFe(CN)6 will be investigated. Prussian blue (A[FeIIIFeII (CN)6]•xH2O, A=Na+ or K+ ) and its analogues have been investigated as an alkali ion host for use as a cathode material. Their structure (FCC) provides large ionic channels along the direction enabling facile insertion and extraction of alkali ions. This material is also capable of more than one Na ion insertion per unit formula which holds great promise in increasing the energy density of the NIB. The electrochemical performance of the cathode material will be analyzed using cyclic voltammetry, and galvanostatic charge/discharge investigation.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-25
... Woolen Mill Company, Faribault, MN; Faribo Woolens, Inc., a Related Company of Faribault Woolen Mill... December 9, 2009, applicable to workers of Faribault Woolen Mill Company, Faribault, Minnesota. The notice... Mill Company, a retail outlet store for the subject firm, Faribault Woolen Mill Company. Accordingly...
32. RW Meyer Sugar Mill: 18761889. Threeroll sugar mill, oneton ...
32. RW Meyer Sugar Mill: 1876-1889. Three-roll sugar mill, one-ton daily processing capacity. Manufactured by Edwin Maw, Liverpool, England, ca. 1855-1870. View: End of mill into which cane was fed between top and bottom roll. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI
Extended-testing of xenon ion thruster hollow cathodes
NASA Technical Reports Server (NTRS)
Sarver-Verhey, Timothy R.
1992-01-01
A hollow cathode wear-test of 508 hours was successfully completed at an emission current of 23.0 A and a xenon flow rate of 10 Pa-L/s. This test was the continuation of a hollow cathode contamination investigation. Discharge voltage was stable at 16.7 V. The cathode temperature averaged 1050 C with a 7 percent drop during the wear-test. Discharge ignition voltage was found to be approximately 20 V and was repeatable over four starts. Post-test analyses of the hollow cathode found a much improved internal cathode condition with respect to earlier wear-test cathodes. Negligible tungsten movement occurred and no formation of mono-barium tungsten was observed. These results correlated with an order-of-magnitude reduction in propellant feed-system leakage rate. Ba2CaWO6 and extensive calcium crystal formation occurred on the upstream end of the insert. Ba-Ca compound depositions were found on the Mo insert collar, on the Re electrical leads, and in the gap between the insert and cathode wall. This wear-test cathode was found to be in the best internal condition and had the most stable operating performance of any hollow cathode tested during this contamination investigation.
Precision grid and hand motion for accurate needle insertion in brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.
2011-08-15
Purpose: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. Methods: The gauge repeatability and reproducibility (GR and R) test was performed on themore » measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2{sup 3} factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. Conclusions: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.« less
40 CFR 63.865 - Performance test requirements and test methods.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the chemical recovery system at the kraft or soda pulp mill, kg/Mg (lb/ton) of black liquor solids... the performance test, megagrams per day (Mg/d) (tons per day (ton/d)) of black liquor solids fired. ER1ref, SDT = reference emission rate of 0.10 kg/Mg (0.20 lb/ton) of black liquor solids fired for...
40 CFR 63.865 - Performance test requirements and test methods.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the chemical recovery system at the kraft or soda pulp mill, kg/Mg (lb/ton) of black liquor solids... the performance test, megagrams per day (Mg/d) (tons per day (ton/d)) of black liquor solids fired. ER1ref, SDT = reference emission rate of 0.10 kg/Mg (0.20 lb/ton) of black liquor solids fired for...
Analytic Solution to the Problem of Aircraft Electric Field Mill Calibration
NASA Technical Reports Server (NTRS)
Koshak, William
2003-01-01
It is by no means a simple task to retrieve storm electric fields from an aircraft instrumented with electric field mill sensors. The presence of the aircraft distorts the ambient field in a complicated way. Before retrievals of the storm field can be made, the field mill measurement system must be "calibrated". In other words, a relationship between impressed (i.e., ambient) electric field and mill output must be established. If this relationship can be determined, it is mathematically inverted so that ambient field can be inferred from the mill outputs. Previous studies have primarily focused on linear theories where the relationship between ambient field and mill output is described by a "calibration matrix" M. Each element of the matrix describes how a particular component of the ambient field is enhanced by the aircraft. For example the product M(sub ix), E(sub x), is the contribution of the E(sub x) field to the i(th) mill output. Similarly, net aircraft charge (described by a "charge field component" E(sub q)) contributes an amount M(sub iq)E(sub q) to the output of the i(th) sensor. The central difficulty in obtaining M stems from the fact that the impressed field (E(sub x), E(sub y), E(sub z), E(sub q) is not known but is instead estimated. Typically, the aircraft is flown through a series of roll and pitch maneuvers in fair weather, and the values of the fair weather field and aircraft charge are estimated at each point along the aircraft trajectory. These initial estimates are often highly inadequate, but several investigators have improved the estimates by implementing various (ad hoc) iterative methods. Unfortunately, none of the iterative methods guarantee absolute convergence to correct values (i.e., absolute convergence to correct values has not been rigorously proven). In this work, the mathematical problem is solved directly by analytic means. For m mills installed on an arbitrary aircraft, it is shown that it is possible to solve for a single 2m-vector that provides all other needed variables (i.e., the unknown fair weather field, the unknown aircraft charge, and the unknown matrix M). Numerical tests of the solution, effects of measurement errors, and studies of solution non-uniqueness are ongoing as of this writing.
Kim, Eun-Ha; Lee, Du-Hyeong; Kwon, Sung-Min; Kwon, Tae-Yub
2017-03-01
Although new digital manufacturing techniques are attracting interest in dentistry, few studies have comprehensively investigated the marginal fit of fixed dental prostheses fabricated with such techniques. The purpose of this in vitro microcomputed tomography (μCT) study was to evaluate the marginal fit of cobalt-chromium (Co-Cr) alloy copings fabricated by casting and 3 different computer-aided design and computer-aided manufacturing (CAD-CAM)-based processing techniques and alloy systems. Single Co-Cr metal crowns were fabricated using 4 different manufacturing techniques: casting (control), milling, selective laser melting, and milling/sintering. Two different commercial alloy systems were used for each fabrication technique (a total of 8 groups; n=10 for each group). The marginal discrepancy and absolute marginal discrepancy of the crowns were determined with μCT. For each specimen, the values were determined from 4 different regions (sagittal buccal, sagittal lingual, coronal mesial, and coronal distal) by using imaging software and recorded as the average of the 4 readings. For each parameter, the results were statistically compared with 2-way analysis of variance and appropriate post hoc analysis (using Tukey or Student t test) (α=.05). The milling and selective laser melting groups showed significantly larger marginal discrepancies than the control groups (70.4 ±12.0 and 65.3 ±10.1 μm, respectively; P<.001), whereas the milling/sintering groups exhibited significantly smaller values than the controls (P=.004). The milling groups showed significantly larger absolute marginal discrepancy than the control groups (137.4 ±29.0 and 139.2 ±18.9 μm, respectively; P<.05). In the selective laser melting and milling/sintering groups, the absolute marginal discrepancy values were material-specific (P<.05). Nonetheless, the milling/sintering groups yielded statistically comparable (P=.935) or smaller (P<.001) absolute marginal discrepancies to the control groups. The findings of this in vitro μCT study showed that the marginal fit values of the Co-Cr alloy greatly depended on the fabrication methods and, occasionally, the alloy systems. Fixed dental prostheses produced by using the milling/sintering technique can be considered clinically acceptable in terms of marginal fit. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Effects of size and age on the survival and growth of pulp and paper mills
Xiaolei Li; Joseph Buongiorno; Peter J. Ince
2004-01-01
The growth of pulp and paper mills in the US from 1970 to 2000 depended mostly on size and age. Mills grew according to Gibratâs law, and post-1970 mills grew faster than pre-1971 mills. Mills stopped growing at approximately 22 years of age. But most mills survived beyond that, thus growth was not necessary for survival, but characteristic of the early phase of the...
Attempted - to -Phase Conversion of Croconic Acid via Ball Milling
2017-05-18
extended milling times may degrade the material. 15. SUBJECT TERMS ball milling, croconic acid, Hertzian stress , C5H2O5, extended solid 16. SECURITY...the motion of the Wig-L-Bug ball mill; from this motion it was possible to determine the velocity parameters needed for Hertzian stress ...Milling Pressures The high pressures achievable in this type of mill result from stresses that develop in the milled material as it is trapped between
1. RW Meyer Sugar Mill: 18761889. Threeroll sugar mill: oneton ...
1. RW Meyer Sugar Mill: 1876-1889. Three-roll sugar mill: one-ton daily processing capacity. Manufactured by Edwin Maw, Liverpool, England, ca. 1855-1870. View: Historical view, 1934, from T.T. Waterman collection, Hawaiian Sugar Planters' Association. Large rectangular piece lying in front of the mill is the top of the mill frame appearing in its proper place in 1928 views. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI
Elevation, west portal. Sign on portal reads Watson Mill Bridge, ...
Elevation, west portal. Sign on portal reads Watson Mill Bridge, est. 1885. - Watson Mill Bridge, Spanning South Fork Broad River, Watson Mill Road, Watson Mill Bridge State Park, Comer, Madison County, GA
Preventive maintenance study : interim report.
DOT National Transportation Integrated Search
2017-09-01
This interim report details the performance of 69 test sites treated with various preventive maintenance treatments. The maintenance treatments applied included crack sealing, full lane chip sealing, wheel path chip sealing, dig outs (mill and fill),...
Filtration effects on ball bearing life and condition in a contaminated lubricant
NASA Technical Reports Server (NTRS)
Loewenthal, S. H.; Moyer, D. W.
1978-01-01
Ball bearings were fatigue tested with a noncontaminated MIL-L-23699 lubricant and with a contaminated MIL-L-23699 lubricant under four levels of filtration. The test filters had absolute particle removal ratings of 3, 30, 49, and 105 microns. Aircraft turbine engine contaminants were injected into the filter's supply line at a constant rate of 125 milligrams per bearing hour. Bearing life and running track condition generally improved with finer filtration. The experimental lives of 3- and 30-micron filter bearings were statistically equivalent, approaching those obtained with the noncontaminated lubricant bearings. Compared to these bearings, the lives of the 49-micron bearings were statistically lower. The 105-micron bearings experienced gross wear. The degree of surface distress, weight loss, and probable failure mode were dependent on filtration level, with finer filtration being clearly beneficial.
New Single Piece Blast Hardware design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ulrich, Andri; Steinzig, Michael Louis; Aragon, Daniel Adrian
W, Q and PF engineers and machinists designed and fabricated, on the new Mazak i300, the first Single Piece Blast Hardware (unclassified design shown) reducing fabrication and inspection time by over 50%. The first DU Single Piece is completed and will be used for Hydro Test 3680. Past hydro tests used a twopiece assembly due to a lack of equipment capable of machining the complex saddle shape in a single piece. The i300 provides turning and milling 5-axis machining on one machine. The milling head on the i300 can machine past 90 relative to the spindle axis. This makes itmore » possible to machine the complex saddle surface on a single piece. Going to a single piece eliminates tolerance problems, such as tilting and eccentricity, that typically occurred when assembling the two pieces together« less
Perturbative quantum gravity as a double copy of gauge theory.
Bern, Zvi; Carrasco, John Joseph M; Johansson, Henrik
2010-08-06
In a previous paper we observed that (classical) tree-level gauge-theory amplitudes can be rearranged to display a duality between color and kinematics. Once this is imposed, gravity amplitudes are obtained using two copies of gauge-theory diagram numerators. Here we conjecture that this duality persists to all quantum loop orders and can thus be used to obtain multiloop gravity amplitudes easily from gauge-theory ones. As a nontrivial test, we show that the three-loop four-point amplitude of N=4 super-Yang-Mills theory can be arranged into a form satisfying the duality, and by taking double copies of the diagram numerators we obtain the corresponding amplitude of N=8 supergravity. We also remark on a nonsupersymmetric two-loop test based on pure Yang-Mills theory resulting in gravity coupled to an antisymmetric tensor and dilaton.
Glycaemic Response to Quality Protein Maize Grits
Panlasigui, Leonora N.; Bayaga, Cecile L. T.; Barrios, Erniel B.; Cochon, Kim L.
2010-01-01
Background. Carbohydrates have varied rates of digestion and absorption that induces different hormonal and metabolic responses in the body. Given the abundance of carbohydrate sources in the Philippines, the determination of the glycaemic index (GI) of local foods may prove beneficial in promoting health and decreasing the risk of diabetes in the country. Methods. The GI of Quality Protein Maize (QPM) grits, milled rice, and the mixture of these two food items were determined in ten female subjects. Using a randomized crossover design, the control bread and three test foods were given on separate occasions after an overnight fast. Blood samples were collected through finger prick at time intervals of 0, 15, 30, 45, 60, 90, and 120 min and analyzed for glucose concentrations. Results. The computed incremental area under the glucose response curve (IAUC) varies significantly across test foods (P < .0379) with the pure QPM grits yielding the lowest IAUC relative to the control by 46.38. Resulting GI values of the test foods (bootstrapped) were 80.36 (SEM 14.24), 119.78 (SEM 18.81), and 93.17 (SEM 27.27) for pure QPM grits, milled rice, and rice-QPM grits mixture, respectively. Conclusion. Pure QPM corn grits has a lower glycaemic response compared to milled rice and the rice-corn grits mixture, which may be related in part to differences in their dietary fibre composition and physicochemical characteristics. Pure QPM corn grits may be a more health beneficial food for diabetic and hyperlipidemic individuals. PMID:20862364
NASA Astrophysics Data System (ADS)
Venkitaraj, K. P.; Suresh, S.; Alwin Mathew, T.; Bibin, B. S.; Abraham, Jisa
2018-03-01
Nanofluids are advanced heat transfer fluids that exhibit thermal properties superior than that of the conventional fluids such as water, oil etc. This paper reports the experimental study on convective heat transfer characteristics of water based titanium dioxide nanofluids in fully developed flow through a uniformly heated pipe heat exchanger fitted with modified butterfly inserts. Nanofluids are prepared by dispersing TiO2 nanoparticles of average particle size 29 nm in deionized water. The heat transfer experiments are performed in laminar regime using nanofluids prepared with 0.1% and 0.3% volume fractions of TiO2 nanoparticles. The thermal performance characteristics of conventional butterfly inserts and modified butterfly inserts are also compared using TiO2 nanofluid. The inserts with different pitches 6 cm, 9 cm and 12 cm are tested to determine the effect of pitch distance of inserts in the heat transfer and friction. The experimental results showed that the modification made in the butterfly inserts were able to produce higher heat transfer than conventional butterfly inserts.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-24
.... Doing Business as Alcoa Mill Products Texarkana a Subsidiary of Alcoa, Inc. Nash, TX; Amended... Mill Products Texarkana, a subsidiary of Alcoa, Inc., Nash, Texas, was separated is Alumax Mill... Alcoa Mill Products Texarkana, a subsidiary of Alcoa, Inc., Nash, Texas, who became totally or partially...
Thermal Design, Analysis, and Testing of the Quench Module Insert Bread Board
NASA Technical Reports Server (NTRS)
Breeding, Shawn; Khodabandeh, Julia
2002-01-01
Contents include the following: Quench Module Insert (QMI) science requirements. QMI interfaces. QMI design layout. QMI thermal analysis and design methodology. QMI bread board testing and instrumentation approach. QMI thermal probe design parameters. Design features for gradient measurement. Design features for heated zone measurements. Thermal gradient analysis results. Heated zone analysis results. Bread board thermal probe layout. QMI bread board correlation and performance. Summary and conclusions.
Acoustic Survey of a 3/8-Scale Automotive Wind Tunnel
NASA Technical Reports Server (NTRS)
Booth, Earl R., Jr.; Romberg, Gary; Hansen, Larry; Lutz, Ron
1996-01-01
An acoustic survey that consists of insertion loss and flow noise measurements was conducted at key locations around the circuit of a 3/8-scale automotive acoustic wind tunnel. Descriptions of the test, the instrumentation, and the wind tunnel facility are included in the current report, along with data obtained in the test in the form of 1/3-octave-band insertion loss and narrowband flow noise spectral data.
Trisi, Paolo; Berardi, Davide; Paolantonio, Michele; Spoto, Giuseppe; D'Addona, Antonio; Perfetti, Giorgio
2013-05-01
Between implants and peri-implant bone, there should be a minimum gap, without micromotions over a threshold, which could cause resorption and fibrosis. The higher the implant insertion torque, the higher will be the initial stability. The aim was to evaluate in vitro the correlation between micromotions and insertion torque of implants in bone of different densities. The test was performed on bovine bone of hard, medium, and soft density: 150 implants were used, 10 for each torque (20, 35, 45, 70, and 100 N/cm). Samples were fixed on a loading device. On each sample, we applied a 25-N horizontal force. Insertion torque and micromotions are statistically correlated. In soft bone with an insertion force of 20 and 35 N/cm, the micromotion resulted significantly over the risk threshold, which was not found with an insertion force of 45 and 70 N/cm and in hard and medium bones with any insertion torque. The increase in insertion torque reduces the amount of micromotions between implant and bone. Therefore, the immediate loading may be considered a valid therapeutic choice, even in low-density bone, as long as at least 45 N/cm of insertion torque is reached.
Grindability determination of torrefied biomass materials using the Hybrid Work index
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Essendelft, D.T.; Zhou, X.; Kang, B.S.-J.
2012-01-01
The grindability of torrefied biomass materials is a difficult parameter to evaluate due to its inhomogeneous character and non-uniform morphology. However, it is necessary to develop a grinding test that is representative of the wide ranging character of biomass and torrefied biomass materials. Previous research has shown that Resistance to Impact Milling (RIM) can be linearly correlated to thermally driven weight loss in biomass. In particular, the RIM equipment was found to supply the right energy level to physically break down structurally deficient biomass materials while leaving the un-touched material relatively intact [1–3]. However, the RIM procedure was not designedmore » to extract the comminution energy. Alternatively, the Bond Work Index (BWI) procedure was developed to accurately assess the grinding energy of brittle materials [4,5]. However, the milling energy is too low to be effective for biomass comminution. In this research, the BWI procedure was utilized with the ball–mill approach in the RIM test to evaluate torrefied biomass materials. The hybridized procedure has been shown to be both highly correlated to energy consumption and sensitive to degree of torrefaction. The proposed Hybrid Work Index (HWI) is certainly useful for assessing torrefaction in a laboratory environment, but it may also be correlated to grinding energy at industrial scales.« less
A High Performance Torque Sensor for Milling Based on a Piezoresistive MEMS Strain Gauge
Qin, Yafei; Zhao, Yulong; Li, Yingxue; Zhao, You; Wang, Peng
2016-01-01
In high speed and high precision machining applications, it is important to monitor the machining process in order to ensure high product quality. For this purpose, it is essential to develop a dynamometer with high sensitivity and high natural frequency which is suited to these conditions. This paper describes the design, calibration and performance of a milling torque sensor based on piezoresistive MEMS strain. A detailed design study is carried out to optimize the two mutually-contradictory indicators sensitivity and natural frequency. The developed torque sensor principally consists of a thin-walled cylinder, and a piezoresistive MEMS strain gauge bonded on the surface of the sensing element where the shear strain is maximum. The strain gauge includes eight piezoresistances and four are connected in a full Wheatstone circuit bridge, which is used to measure the applied torque force during machining procedures. Experimental static calibration results show that the sensitivity of torque sensor has been improved to 0.13 mv/Nm. A modal impact test indicates that the natural frequency of torque sensor reaches 1216 Hz, which is suitable for high speed machining processes. The dynamic test results indicate that the developed torque sensor is stable and practical for monitoring the milling process. PMID:27070620
Akça, Ozan; Wadhwa, Anupama; Sengupta, Papiya; Durrani, Jaleel; Hanni, Keith; Wenke, Mary; Yücel, Yüksel; Lenhardt, Rainer; Doufas, Anthony G.; Sessler, Daniel I.
2006-01-01
The Laryngeal Mask Airway (LMA) is a frequently-used efficient airway device, yet it sometimes seals poorly, thus reducing the efficacy of positive-pressure ventilation. The Perilaryngeal Airway (CobraPLA) is a novel airway device with a larger pharyngeal cuff (when inflated). We tested the hypothesis that the CobraPLA was superior to LMA with regard to insertion time and airway sealing pressure and comparable to LMA in airway adequacy and recovery characteristics. After midazolam and fentanyl, 81 ASA I-II outpatients having elective surgery were randomized to receive an LMA or CobraPLA. Anesthesia was induced with propofol (2.5 mg/kg, IV), and the airway inserted. We measured 1) insertion time; 2) adequacy of the airway (no leak at 15-cm-H2O peak pressure or tidal volume of 5 ml/kg); 3) airway sealing pressure; 4) number of repositioning attempts; and 5) sealing quality (no leak at tidal volume of 8 ml/kg). At the end of surgery, gastric insufflation, postoperative sore throat, dysphonia, and dysphagia were evaluated. Data were compared with unpaired t-tests, chi-square tests, or Fisher’s Exact tests; P<0.05 was significant. Patient characteristics, insertion times, airway adequacy, number of repositioning attempts, and recovery were similar in each group. Airway sealing pressure was significantly greater with CobraPLA (23±6 cm H2O) than LMA (18±5 cm H2O, P<0.001). The CobraPLA has insertion characteristics similar to LMA, but better airway sealing capabilities. PMID:15281543
Tuna, Süleyman Hakan; Özçiçek Pekmez, Nuran; Kürkçüoğlu, Işin
2015-11-01
The effects of fabrication methods on the corrosion resistance of frameworks produced with Co-Cr alloys are not clear. The purpose of this in vitro study was to evaluate the electrochemical corrosion resistance of Co-Cr alloy specimens that were fabricated by conventional casting, milling, and laser sintering. The specimens fabricated with 3 different methods were investigated by potentiodynamic tests and electrochemical impedance spectroscopy in an artificial saliva. Ions released into the artificial saliva were estimated with inductively coupled plasma-mass spectrometry, and the results were statistically analyzed. The specimen surfaces were investigated with scanning electron microscopy before and after the tests. In terms of corrosion current and Rct properties, statistically significant differences were found both among the means of the methods and among the means of the material groups (P<.05). With regard to ions released, a statistically significant difference was found among the material groups (P<.05); however, no difference was found among the methods. Scanning electron microscopic imaging revealed that the specimens produced by conventional casting were affected to a greater extent by etching and electrochemical corrosion than those produced by milling and laser sintering. The corrosion resistance of a Co-Cr alloy specimens fabricated by milling or laser sintering was greater than that of the conventionally cast alloy specimens. The Co-Cr specimens produced by the same method also differed from one another in terms of corrosion resistance. These differences may be related to the variations in the alloy compositions. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Damayanti, A; Ujang, Z; Salim, M R
2011-03-01
The main objective of this work was to determine the effectiveness of various biofouling reducers (BFRs) to operational condition in hybrid membrane bioreactor (MBR) of palm oil mill effluent (POME). A series of tests involving three bench scale (100 L) hybrid MBR were operated at sludge retention times (SRTs) of 30 days with biofouling reducer (BFR). Three different biofouling reducers (BFRs) were powdered actived carbon (PAC), zeolite (Ze), and Moringa oleifera (Mo) with doses of 4, 8 and 12 g L(-1) respectively were used. Short-term filtration trials and critical flux tests were conducted. Results showed that, all BFRs successfully removed soluble microbial products (SMP), for PAC, Ze, and Mo at 58%, 42%, and 48%, respectively. At their optimum dosages, PAC provided above 70% reductions and 85% in fouling rates during the short-term filtration and critical flux tests. Copyright © 2010 Elsevier Ltd. All rights reserved.
Reuse of municipal solid wastes incineration fly ashes in concrete mixtures.
Collivignarelli, Carlo; Sorlini, Sabrina
2002-01-01
This study is aimed at assessing the feasibility of concrete production using stabilized m.s.w. (municipal solid waste) incineration fly ashes in addition to natural aggregates. The tested fly ashes were washed and milled, then stabilized by a cement-lime process and finally were reused as a "recycled aggregate" for cement mixture production, in substitution of a natural aggregate (with dosage of 200-400 kg m(-3)). These mixtures, after curing, were characterized with conventional physical-mechanical tests (compression, traction, flexure, modulus of elasticity, shrinkage). In samples containing 200 kg(waste) m(-3)(concrete), a good compressive strength was achieved after 28 days of curing. Furthermore, concrete leaching behavior was evaluated by means of different leaching tests, both on milled and on monolithic samples. Experimental results showed a remarkable reduction of metal leaching in comparison with raw waste. In some cases, similar behavior was observed in "natural" concrete (produced with natural aggregates) and in "waste containing" concrete.
4. APPROACH OF CARRS MILL ROAD TO THE SOUTH PORTAL ...
4. APPROACH OF CARRS MILL ROAD TO THE SOUTH PORTAL OF THE MITCHELLS MILL BRIDGE; VIEW TO NORTH. - Mitchell's Mill Bridge, Spanning Winter's Run on Carrs Mill Road, west of Bel Air, Bel Air, Harford County, MD
7. VIEW TO EAST, MILL WAREHOUSE, DRYERS, GRINDING/ROD MILL, AND ...
7. VIEW TO EAST, MILL WAREHOUSE, DRYERS, GRINDING/ROD MILL, AND MECHANIC SHED. - Vanadium Corporation of America (VCA) Naturita Mill, 3 miles Northwest of Naturita, between Highway 141 & San Miguel River, Naturita, Montrose County, CO
Revitalizing America's Mills: A Report on Brownfields Mill Projects
This report focuses on mills -- former textile, wood, paper, iron, and steel mills. The report describes the challenges and opportunities of mill sites with case studies highlighting some of the most creative solutions from across the country.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-19
... Lands, as an Addition to the Bay Mills Indian Reservation for the Bay Mills Indian Community of Michigan... acres, more or less, to be added to the Bay Mills Indian Reservation for the Bay Mills Indian Community... the land described below. The land was proclaimed to be an addition to the Bay Mills Indian...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-05
... an Addition to the Bay Mills Indian Reservation for the Bay Mills Indian Community of Michigan AGENCY..., more or less, to be added to the Bay Mills Indian Reservation for the Bay Mills Indian Community of... the land described below. The land was proclaimed to be an addition to the Bay Mills Indian...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-13
... Acquisition, as an Addition to the Bay Mills Indian Reservation for the Bay Mills Indian Community of Michigan..., more or less, to be added to the Bay Mills Indian Reservation for the Bay Mills Indian Community of... the land described below. The land was proclaimed to be an addition to the Bay Mills Indian...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-18
..., as an Addition to the Bay Mills Indian Reservation for the Bay Mills Indian Community of Michigan..., more or less, to be added to the Bay Mills Indian Reservation for the Bay Mills Indian Community of... the land described below. The land was proclaimed to be an addition to the Bay Mills Indian...
3. Interior of the attic of Mill No. 1, looking ...
3. Interior of the attic of Mill No. 1, looking west. Unlike Mill No. 2 or the Sugar River Grist Mill, there were no iron tension members in this roof truss design. The structural framing members and the roof sheathing have been encased in finish millwork. - Monadnock Mills, Mill No. 1, 13-17 Water Street, Claremont, Sullivan County, NH
34. RW Meyer Sugar Mill: 18761889. Threeroll sugar mill, oneton ...
34. RW Meyer Sugar Mill: 1876-1889. Three-roll sugar mill, one-ton daily processing capacity. Manufactured by Edwin Maw, Liverpool, England, ca. 1855-1870. View: Side view of mill. Vertical drive shaft lying on ground in foreground. When drive-shaft was in upright position its bevel gear was meshed with the bevel gear of the top roll, transmitting the animals'circular motion around the drive shaft to the horizontal rolls. The foundation is of portland cement. The heavy timber mill bed, between the mill and the portland cement foundation has rolled away. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI
Neill, Nicholas J; Ballif, Blake C; Lamb, Allen N; Parikh, Sumit; Ravnan, J Britt; Schultz, Roger A; Torchia, Beth S; Rosenfeld, Jill A; Shaffer, Lisa G
2011-04-01
Insertions occur when a segment of one chromosome is translocated and inserted into a new region of the same chromosome or a non-homologous chromosome. We report 71 cases with unbalanced insertions identified using array CGH and FISH in 4909 cases referred to our laboratory for array CGH and found to have copy-number abnormalities. Although the majority of insertions were non-recurrent, several recurrent unbalanced insertions were detected, including three der(Y)ins(Y;18)(q?11.2;p11.32p11.32)pat inherited from parents carrying an unbalanced insertion. The clinical significance of these recurrent rearrangements is unclear, although the small size, limited gene content, and inheritance pattern of each suggests that the phenotypic consequences may be benign. Cryptic, submicroscopic duplications were observed at or near the insertion sites in two patients, further confounding the clinical interpretation of these insertions. Using FISH, linear amplification, and array CGH, we identified a 126-kb duplicated region from 19p13.3 inserted into MECP2 at Xq28 in a patient with symptoms of Rett syndrome. Our results demonstrate that although the interpretation of most non-recurrent insertions is unclear without high-resolution insertion site characterization, the potential for an otherwise benign duplication to result in a clinically relevant outcome through the disruption of a gene necessitates the use of FISH to determine whether copy-number gains detected by array CGH represent tandem duplications or unbalanced insertions. Further follow-up testing using techniques such as linear amplification or sequencing should be used to determine gene involvement at the insertion site after FISH has identified the presence of an insertion.
Redundant via insertion in self-aligned double patterning
NASA Astrophysics Data System (ADS)
Song, Youngsoo; Jung, Jinwook; Shin, Youngsoo
2017-03-01
Redundant via (RV) insertion is employed to enhance via manufacturability, and has been extensively studied. Self-aligned double patterning (SADP) process, brings a new challenge to RV insertion since newly created cut for each RV insertion has to be taken care of. Specifically, when a cut for RV, which we simply call RV-cut, is formed, cut conflict may occur with nearby line-end cuts, which results in a decrease in RV candidates. We introduce cut merging to reduce the number of cut conflicts; merged cuts are processed with stitch using litho-etch-litho-etch (LELE) multi-patterning method. In this paper, we propose a new RV insertion method with cut merging in SADP for the first time. In our experiments, a simple RV insertion yields 55.3% vias to receives RVs; our proposed method that considers cut merging increases that number to 69.6% on average of test circuits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunt, J.G.; Jenkins, R.G.; White, A.M.
1963-03-01
A number of ceramics, metallic compounds, and ceramic-metal composites were successfully hot pressed into the shape of die inserts. Steels were extruded through several of these for the purpose of evaluating the materials or to study methods of supporting the die inserts. Refractory metal inserts were also used in similar tests. Hot pressed inserts consisting of 80 vo1% Al/sub 2/O/ sub 3/--10 vol% W and 80 vol% ThO/sub 2/--10 vol% W cracked but did not erode. Sintered molybdenum inserts flowed excessively, whereas sintered tungsten inserts flowed to a lesser degree. A hard die casing with a slight shrink fit appearsmore » to be the most satisfactory method of support. (auth)« less
NASA Technical Reports Server (NTRS)
Crouch, Myscha; Carswell, Bill; Farmer, Jeff; Rose, Fred; Tidwell, Paul
2000-01-01
The Material Science Research Rack I (MSRR-1) of the Material Science Research Facility (MSRF) contains an Experiment Module (EM) being developed collaboratively by NASA and the European Space Agency (ESA). This NASA/ESA EM will accommodate several different removable and replaceable Module Inserts (MIs) which are installed on orbit NASA's planned inserts include the Quench Module Insert (QMI) and the Diffusion Module Insert (DMI). The QMI is a high-gradient Bridgman-type vacuum furnace with quench capabilities used for experiments on directional solidification of metal alloys. The DMI is a vacuum Bridgman-Stockbarger-type furnace for experiments on Fickian and Soret diffusion in liquids. This paper discusses specific design features and performance capabilities of each insert. The paper also presents current prototype QMI hardware analysis and testing activities and selected results.
Increasing Inferential Leverage in the Comparative Method: Placebo Tests in Small-"n" Research
ERIC Educational Resources Information Center
Glynn, Adam N.; Ichino, Nahomi
2016-01-01
We delineate the underlying homogeneity assumption, procedural variants, and implications of the comparative method and distinguish this from Mill's method of difference. We demonstrate that additional units can provide "placebo" tests for the comparative method even if the scope of inference is limited to the two units under comparison.…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-21
... to 19 CFR 151.12 and 19 CFR 151.13, Inspectorate America Corporation, 5237 Halls Mill Road-- Building F, Mobile, AL 36619, has been approved to gauge and accredited to test petroleum and petroleum... Border Protection to conduct the specific test or gauger service requested. [[Page 57480
Magnetic strength and corrosion of rare earth magnets.
Ahmad, Khalid A; Drummond, James L; Graber, Thomas; BeGole, Ellen
2006-09-01
Rare earth magnets have been used in orthodontics, but their corrosion tendency in the oral cavity limits long-term clinical application. The aim of this project was to evaluate several; magnet coatings and their effects on magnetic flux density. A total of 60 neodymium-iron-boron magnets divided into 6 equal groups--polytetrafluoroethylene-coated (PTFE), parylene-coated, and noncoated--were subjected to 4 weeks of aging in saline solution, ball milling, and corrosion testing. A significant decrease in magnet flux density was recorded after applying a protective layer of parylene, whereas a slight decrease was found after applying a protective layer of PTFE. After 4 weeks of aging, the coated magnets were superior to the noncoated magnets in retaining magnetism. The corrosion-behavior test showed no significant difference between the 2 types of coated magnets, and considerable amounts of iron-leached ions were seen in all groups. Throughout the processes of coating, soaking, ball milling, and corrosion testing, PTFE was a better coating material than parylene for preserving magnet flux density. However, corrosion testing showed significant metal leaching in all groups.
Effects of metal mining and milling on boundary waters of Yellowstone National Park, USA
Nimmo, D.R.; Willox, M.J.; Lafrancois, T.D.; Chapman, P.L.; Brinkman, S.F.; Greene, J.C.
1998-01-01
Aquatic resources in Soda Butte Creek within Yellowstone National Park, USA, continue to be threatened by heavy metals from historical mining and milling activities that occurred upstream of the park's boundary. This includes the residue of gold, silver, and copper ore mining and processing in the early 1900s near Cooke City, Montana, just downstream of the creek's headwaters. Toxicity tests, using surrogate test species, and analyses of metals in water, sediments, and macroinvertebrate tissue were conducted from 1993 to 1995. Chronic toxicity to test species was greater in the spring than the fall and metal concentrations were elevated in the spring with copper exceeding water quality criteria in 1995. Tests with amphipods using pore water and whole sediment from the creek and copper concentrations in the tissue of macroinvertebrates and fish also suggest that copper is the metal of concern in the watershed. In order to understand current conditions in Soda Butte Creek, heavy metals, especially copper, must be considered important factors in the aquatic and riparian ecosystems within and along the creek extending into Yellowstone National Park.
Testing of Face-milled Spiral Bevel Gears at High-speed and Load
NASA Technical Reports Server (NTRS)
Handschuh, Robert F.
2001-01-01
Spiral bevel gears are an important drive system components of rotorcraft (helicopters) currently in use. In this application the spiral bevel gears are required to transmit very high torque at high rotational speed. Available experimental data on the operational characteristics for thermal and structural behavior is relatively small in comparison to that found for parallel axis gears. An ongoing test program has been in place at NASA Glenn Research Center over the last ten years to investigate their operational behavior at operating conditions found in aerospace applications. This paper will summarize the results of the tests conducted on face-milled spiral bevel gears. The data from the pinion member (temperature and stress) were taken at conditions from slow-roll to 14400 rpm and up to 537 kW (720 hp). The results have shown that operating temperature is affected by the location of the lubricating jet with respect to the point it is injected and the operating conditions that are imposed. Also the stress measured from slow-roll to very high rotational speed, at various torque levels, indicated little dynamic affect over the rotational speeds tested.
Retrieving Storm Electric Fields From Aircraft Field Mill Data. Part 2; Applications
NASA Technical Reports Server (NTRS)
Koshak, W. J.; Mach, D. M.; Christian, H. J.; Stewart, M. F.; Bateman, M. G.
2005-01-01
The Lagrange multiplier theory and "pitch down method" developed in Part I of this study are applied to complete the calibration of a Citation aircraft that is instrumented with six field mill sensors. When side constraints related to average fields are used, the method performs well in computer simulations. For mill measurement errors of 1 V/m and a 5 V/m error in the mean fair weather field function, the 3-D storm electric field is retrieved to within an error of about 12%. A side constraint that involves estimating the detailed structure of the fair weather field was also tested using computer simulations. For mill measurement errors of 1 V/m, the method retrieves the 3-D storm field to within an error of about 8% if the fair weather field estimate is typically within 1 V/m of the true fair weather field. Using this side constraint and data from fair weather field maneuvers taken on 29 June 2001, the Citation aircraft was calibrated. The resulting calibration matrix was then used to retrieve storm electric fields during a Citation flight on 2 June 2001. The storm field results are encouraging and agree favorably with the results obtained from earlier calibration analyses that were based on iterative techniques.
Dioxins reformation and destruction in secondary copper smelting fly ash under ball milling
Cagnetta, Giovanni; Hassan, Mohammed Mansour; Huang, Jun; Yu, Gang; Weber, Roland
2016-01-01
Secondary copper recovery is attracting increasing interest because of the growth of copper containing waste including e-waste. The pyrometallurgical treatment in smelters is widely utilized, but it is known to produce waste fluxes containing a number of toxic pollutants due to the large amount of copper involved, which catalyses the formation of polychlorinated dibenzo-p-dioxins and dibenzofurans (“dioxins”). Dioxins are generated in secondary copper smelters on fly ash as their major source, resulting in highly contaminated residues. In order to assess the toxicity of this waste, an analysis of dioxin-like compounds was carried out. High levels were detected (79,090 ng TEQ kg−1) in the ash, above the Basel Convention low POPs content (15,000 ng TEQ kg−1) highlighting the hazardousness of this waste. Experimental tests of high energy ball milling with calcium oxide and silica were executed to assess its effectiveness to detoxify such fly ash. Mechanochemical treatment obtained 76% dioxins reduction in 4 h, but longer milling time induced a partial de novo formation of dioxins catalysed by copper. Nevertheless, after 12 h treatment the dioxin content was substantially decreased (85% reduction) and the copper, thanks to the phenomena of incorporation and amorphization that occur during milling, was almost inactivated. PMID:26975802
Li, Jieyin; Ye, Xiuhua; Li, Bohua; Liao, Juankun; Zhuang, Peilin; Ye, Jiantao
2015-08-01
There is a dearth of dental scientific literature on the effect of different oxidation heat treatments (OHTs) (as surface pretreatments) on the bonding performance of cast and milled cobalt-chromium (CoCr) alloys. The objective of this study was to evaluate the effect of different OHTs on the bond strength between a ceramic and cast and milled CoCr alloys. Cobalt-chromium metallic specimens were prepared using either a cast or a milled method. Specimens were subjected to four different OHT methods: without OHT; OHT under normal atmospheric pressure; OHT under vacuum; and OHT under vacuum followed by sandblasting. The metal-ceramic bond strength was evaluated using a three-point bending test according to ISO9693. Scanning electron microscopy and energy-dispersive spectroscopy were used to study the specimens' microstructure and elemental composition. The bond strength was not affected by the CoCr manufacturing method. Oxidation heat treatment performed under normal atmospheric pressure resulted in the highest bond strength. The concentration of oxygen on the alloy surfaces varied with the different pretreatment methods in the following order: OHT under normal atmospheric pressure > OHT under vacuum > without OHT ≈ OHT under vacuum followed by sandblasting. © 2015 Eur J Oral Sci.
Dioxins reformation and destruction in secondary copper smelting fly ash under ball milling
NASA Astrophysics Data System (ADS)
Cagnetta, Giovanni; Hassan, Mohammed Mansour; Huang, Jun; Yu, Gang; Weber, Roland
2016-03-01
Secondary copper recovery is attracting increasing interest because of the growth of copper containing waste including e-waste. The pyrometallurgical treatment in smelters is widely utilized, but it is known to produce waste fluxes containing a number of toxic pollutants due to the large amount of copper involved, which catalyses the formation of polychlorinated dibenzo-p-dioxins and dibenzofurans (“dioxins”). Dioxins are generated in secondary copper smelters on fly ash as their major source, resulting in highly contaminated residues. In order to assess the toxicity of this waste, an analysis of dioxin-like compounds was carried out. High levels were detected (79,090 ng TEQ kg-1) in the ash, above the Basel Convention low POPs content (15,000 ng TEQ kg-1) highlighting the hazardousness of this waste. Experimental tests of high energy ball milling with calcium oxide and silica were executed to assess its effectiveness to detoxify such fly ash. Mechanochemical treatment obtained 76% dioxins reduction in 4 h, but longer milling time induced a partial de novo formation of dioxins catalysed by copper. Nevertheless, after 12 h treatment the dioxin content was substantially decreased (85% reduction) and the copper, thanks to the phenomena of incorporation and amorphization that occur during milling, was almost inactivated.
7 CFR 868.306 - Milling requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... FOR CERTAIN AGRICULTURAL COMMODITIES United States Standards for Milled Rice Principles Governing Application of Standards § 868.306 Milling requirements. The degree of milling for milled rice; i.e., “hard... interpretive line samples for such rice. [67 FR 61250, Sept. 30, 2002] ...
7 CFR 868.306 - Milling requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... FOR CERTAIN AGRICULTURAL COMMODITIES United States Standards for Milled Rice Principles Governing Application of Standards § 868.306 Milling requirements. The degree of milling for milled rice; i.e., “hard... interpretive line samples for such rice. [67 FR 61250, Sept. 30, 2002] ...
NASA Astrophysics Data System (ADS)
Omidvari, Negar; Topping, Geoffrey; Cabello, Jorge; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I.
2018-05-01
Compromises in the design of a positron emission tomography (PET) insert for a magnetic resonance imaging (MRI) system should minimize the deterioration of image quality in both modalities, particularly when simultaneous demanding acquisitions are performed. In this work, the advantages of using individually read-out crystals with high-gain silicon photomultipliers (SiPMs) were studied with a small animal PET insert for a 7 T MRI system, in which the SiPM charge was transferred to outside the MRI scanner using coaxial cables. The interferences between the two systems were studied with three radio-frequency (RF) coil configurations. The effects of PET on the static magnetic field, flip angle distribution, RF noise, and image quality of various MRI sequences (gradient echo, spin echo, and echo planar imaging (EPI) at 1H frequency, and chemical shift imaging at 13C frequency) were investigated. The effects of fast-switching gradient fields and RF pulses on PET count rate were studied, while the PET insert and the readout electronics were not shielded. Operating the insert inside a 1H volume coil, used for RF transmission and reception, limited the MRI to T1-weighted imaging, due to coil detuning and RF attenuation, and resulted in significant PET count loss. Using a surface receive coil allowed all tested MR sequences to be used with the insert, with 45–59% signal-to-noise ratio (SNR) degradation, compared to without PET. With a 1H/13C volume coil inside the insert and shielded by a copper tube, the SNR degradation was limited to 23–30% with all tested sequences. The insert did not introduce any discernible distortions into images of two tested EPI sequences. Use of truncated sinc shaped RF excitation pulses and gradient field switching had negligible effects on PET count rate. However, PET count rate was substantially affected by high-power RF block pulses and temperature variations due to high gradient duty cycles.
NASA Astrophysics Data System (ADS)
Verma, Aditya; Kumar, Manoj; Patil, Anil Kumar
2018-04-01
The application of compact heat exchangers in any thermal system improves overall performance with a considerable reduction in size and weight. Inserts of different geometrical features have been used as turbulence promoting devices to increase the heat transfer rates. The present study deals with the experimental investigation of heat transfer and fluid flow characteristics of a tubular heat exchanger fitted with modified helical coiled inserts. Experiments have been carried out for a smooth tube without insert, tube fitted with helical coiled inserts, and modified helical coiled inserts. The helical coiled inserts are tested by varying the pitch ratio and wire diameter ratio from 0.5-1.5, and 0.063-0.125, respectively for the Reynolds number range of 1400 to 11,000. Experimental data have also been collected for the modified helical coiled inserts with gradually increasing pitch (GIP) and gradually decreasing pitch (GDP) configurations. The Nusselt number and friction factor values for helical coiled inserts are enhanced in the range of 1.42-2.62, 3.4-27.4, relative to smooth tube, respectively. The modified helical coiled insert showed enhancements in Nusselt number and friction factor values in the range of 1.49-3.14, 11.2-19.9, relative to smooth tube, respectively. The helical coiled and modified helical coiled inserts have thermo-hydraulic performance factor in the range of 0.59-1.29, 0.6-1.39, respectively. The empirical correlations of Nusselt number and friction factor for helical coiled inserts are proposed.
Hornof, Margit; Weyenberg, Wim; Ludwig, Annick; Bernkop-Schnürch, Andreas
2003-05-20
The aim of the study was to develop a mucoadhesive ocular insert for the controlled delivery of ophthalmic drugs and to evaluate its efficacy in vivo. The inserts tested were based either on unmodified or thiolated poly(acrylic acid). Water uptake and swelling behavior of the inserts as well as the drug release rates of the model drugs fluorescein and two diclofenac salts with different solubility properties were evaluated in vitro. Fluorescein was used as fluorescent tracer to study the drug release from the insert in humans. The mean fluorescein concentration in the cornea/tearfilm compartment as a function of time was determined after application of aqueous eye drops and inserts composed of unmodified and of thiolated poly(acrylic acid). The acceptability of the inserts by the volunteers was also evaluated. Inserts based on thiolated poly(acrylic acid) were not soluble and had good cohesive properties. A controlled release was achieved for the incorporated model drugs. The in vivo study showed that inserts based on thiolated poly(acrylic acid) provide a fluorescein concentration on the eye surface for more than 8 h, whereas the fluorescein concentration rapidly decreased after application of aqueous eye drops or inserts based on unmodified poly(acrylic acid). Moreover, these inserts were well accepted by the volunteers. The present study indicates that ocular inserts based on thiolated poly(acrylic acid) are promising new solid devices for ocular drug delivery.
Ning, Shaoli; Zhao, Lihua; Xu, Lingjun; Huang, Yu; Pang, Yong; Huang, Dingjian
2016-01-01
To compare the effects between slow twisting needle insertion and tubing needle insertion. With cross-over design, 100 healthy young subjects (half male and half female) aged from 19 to 23 years were randomly divided into two groups by random digital table, 50 cases in each one. At the first stage, subjects in the group A were treated with slow twisting needle insertion while, subjects in,the group B were treated with tubing needle insertion. One week later, the procedure of second stage was performed alternately. The needle was inserted into Neiguan (PC 6) with two methods by one acupuncturist. The needle was retained for 5 min before removal. Five min before needle insertion as well as needle withdrawal and 30 min after needle withdrawal, ZXG-E automatic cardiovascular diagnostic apparatus was used to test cardiovascular function. At the tim of needle withdrawal, slow twisting needle insertion could improve effect work of kinetics (EWK), effective blood volume (BV) and reduce elastic expansion coefficient of blood vessel (FEK) and left ventricular spray blood impedance (VER), which was significantly different from tubing needle insertion (all P < 0.05). Thirty min after needle withdrawal, the differences of the indices of cardiovascular function between the two groups were not significant (all P > 0.05). The slow twisting needle insertion is significantly superior to tubing needle insertion on lowering vascular tension and VER, improving EWK and BV.
Incomplete Lineage Sorting and Hybridization Statistics for Large-Scale Retroposon Insertion Data
Kuritzin, Andrej; Kischka, Tabea
2016-01-01
Ancient retroposon insertions can be used as virtually homoplasy-free markers to reconstruct the phylogenetic history of species. Inherited, orthologous insertions in related species offer reliable signals of a common origin of the given species. One prerequisite for such a phylogenetically informative insertion is that the inserted element was fixed in the ancestral population before speciation; if not, polymorphically inserted elements may lead to random distributions of presence/absence states during speciation and possibly to apparently conflicting reconstructions of their ancestry. Fortunately, such misleading fixed cases are relatively rare but nevertheless, need to be considered. Here, we present novel, comprehensive statistical models applicable for (1) analyzing any pattern of rare genomic changes, (2) testing and differentiating conflicting phylogenetic reconstructions based on rare genomic changes caused by incomplete lineage sorting or/and ancestral hybridization, and (3) differentiating between search strategies involving genome information from one or several lineages. When the new statistics are applied, in non-conflicting cases a minimum of three elements present in both of two species and absent in a third group are considered significant support (p<0.05) for the branching of the third from the other two, if all three of the given species are screened equally for genome or experimental data. Five elements are necessary for significant support (p<0.05) if a diagnostic locus derived from only one of three species is screened, and no conflicting markers are detected. Most potentially conflicting patterns can be evaluated for their significance and ancestral hybridization can be distinguished from incomplete lineage sorting by considering symmetric or asymmetric distribution of rare genomic changes among possible tree configurations. Additionally, we provide an R-application to make the new KKSC insertion significance test available for the scientific community at http://retrogenomics.uni-muenster.de:3838/KKSC_significance_test/. PMID:26967525
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Wenguang, E-mail: zhwg@sjtu.edu.cn; Ma, Yakun; Li, Zhengwei
Purpose: The application of neural probes in clinic has been challenged by probes’ short lifetime when implanted into brain tissue. The primary goal is to develop an evaluation system for testing brain tissue injury induced by neural probe’s insertion using microscope based digital image correlation method. Methods: A brain tissue phantom made of silicone rubber with speckle pattern on its surface was fabricated. To obtain the optimal speckle pattern, mean intensity gradient parameter was used for quality assessment. The designed testing system consists of three modules: (a) load module for simulating neural electrode implantation process; (b) data acquisition module tomore » capture micrographs of speckle pattern and to obtain reactive forces during the insertion of the probe; (c) postprocessing module for extracting tissue deformation information from the captured speckle patterns. On the basis of the evaluation system, the effects of probe wedge angle, insertion speed, and probe streamline on insertion induced tissue injury were investigated. Results: The optimal quality speckle pattern can be attained by the following fabrication parameters: spin coating rate—1000 r/min, silicone rubber component A: silicone rubber component B: softener: graphite = 5 ml: 5 ml: 2 ml: 0.6 g. The probe wedge angle has a significant effect on tissue injury. Compared to wedge angle 40° and 20°, maximum principal strain of 60° wedge angle was increased by 40.3% and 87.5%, respectively; compared with a relatively higher speed (500 μm/s), the maximum principle strain within the tissue induced by slow insertion speed (100 μm/s) was increased by 14.3%; insertion force required by probe with convex streamline was smaller than the force of traditional probe. Based on the experimental results, a novel neural probe that has a rounded tip covered by a biodegradable silk protein coating with convex streamline was proposed, which has both lower insertion and micromotion induced tissue injury. Conclusions: The established evaluation system has provided a simulation environment for testing brain tissue injury produced by various insertion conditions. At the same time, it eliminates the adverse effect of biological factors on tissue deformation during the experiment, improving the repeatability of measurement results. As a result, the evaluation system will provide support on novel neural probe design that can reduce the acute tissue injury during the implantation of the probe.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-13
... Acquisition, as an Addition to the Bay Mills Indian Reservation for the Bay Mills Indian Community of Michigan..., more or less, to be added to the Bay Mills Indian Reservation for the Bay Mills Indian Community of... the land described below. The land was proclaimed to be an addition to the Bay Mills Indian...
NASA Astrophysics Data System (ADS)
El-Eskandarany, M. Sherif
2017-05-01
The room-temperature reactive ball milling (RBM) approach was employed to synthesize nanostructured fcc-titanium nitride (TiN) powders, starting from milling hcp-titanium (Ti) powders under 10 bar of a nitrogen gas atmosphere, using a roller mill. During the first and intermediate stage of milling, the agglomerated Ti powders were continuously disintegrated into smaller particles with fresh surfaces. Increasing the RBM time led to an increase in the active-fresh surfaces of Ti, resulting increasing of the mole fraction of TiN against unreacted hcp-Ti. Toward the end of the RBM time (20 h), ultrafine spherical powder (with particles 0.5 μm in diameter) of the fcc-TiN phase was obtained, composed of nanocrystalline grains with an average diameter of 8 nm. The samples obtained after different stages of RBM time were consolidated under vacuum at 1600 °C into cylindrical bulk compacts of 20 mm diameter, using spark plasma sintering technique. These compacts that maintained their nanocrystalline characteristics with an average grain size of 56 nm in diameter, possessed high relative density (above 99% of the theoretical density). The Vickers hardness of the as-consolidated TiN was measured and found to be 22.9 GPa. The modulus of elasticity and shear modulus of bulk TiN were measured by a nondestructive test and found to be 384 and 189 GPa, respectively. In addition, the coefficient of friction of the end-product TiN bulk sample was measured and found to be 0.35.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, D.B.; Glaves, C.L.,
1987-07-01
Three model boilers, manufactured to simulate full-size tube sheet crevices, were tested with various secondary side environments. The first was faulted with organics representative of the decomposition of humic acid. The second was faulted with sodium carbonate and sodium hydroxide, while the third was faulted with sodium sulfate and sodium hydroxide. Each model contained seven tubes, which included Alloy 600 in the mill-annealed (MA) and thermally-treated (TT) conditions and Alloy 690 in the thermally-treated condition. Two models contained Alloy 800 tubes in the mill-annealed condition and one had Alloy 800 in the mill-annealed/cold-worked/glass-bead-peened condition. Two different sizes of tubesheet crevicesmore » were used in all model boilers. In the organics-faulted boiler, tubes of Alloy 600MA, Alloy 690TT and Alloy 800MA experienced no significant intergranular attack (IGA); however, the Alloy 600TT had intergranular attack (IGA) three to four grains deep. The carbonate-caustic faulted boiler experienced throughwall stress corrosion cracking (SCC) in all tubes of Alloy 600 MA and Alloy 800 MA. Eddy current indications were present in Alloy 690TT, Alloy 600TT and Alloy 800 in the mill-annealed/cold worked/glass-bead-peened condition. Metallographic examination of tubes from the third model boiler, faulted with sodium sulfate and caustic, revealed IGA in the mill-annealed Alloy 600 tubes. The IGA was more extensive in an Alloy 600 tube annealed at 1700/sup 0/F than an Alloy 600 tube annealed at 1875/sup 0/F.« less
Sudha, Vasudevan; Spiegelman, Donna; Hong, Biling; Malik, Vasanti; Jones, Clara; Wedick, Nicole M.; Hu, Frank B.; Willett, Walter; Bai, Mookambika Ramya; Ponnalagu, Muthu Mariyammal; Arumugam, Kokila; Mohan, Viswanathan
2013-01-01
Objectives To study consumer acceptance of unmilled brown and under milled rice among urban south Indians. Methods Overweight and normal weight adults living in slum and non-slum residences in Chennai participated (n=82). Bapatla (BPT) and Uma (red pigmented) rice varieties were chosen. These rice varieties were dehusked (unmilled, 0% polish) and further milled to 2.3% and 4.4% polishing (under milled). Thus nine rice samples in both raw and parboiled forms were provided for consumer tasting over a period of three days. A hedonic 7-point scale was used to rate the consumer preferences. A validated questionnaire was used to collect demographic, anthropometric, medical history, physical activity, dietary intake data and willingness of the consumers to switch over to brown rice. Results Consumers reported that the color, appearance, texture, taste and overall quality of the 4.4% polished rice was strongly preferred in both varieties and forms. Ratings for 0% polished (brown rice) were substantially lower than those of 2.3% polished rice, which were intermediate in ratings between 0% and 4.4% polishing. However, most of the consumers (93%) expressed willingness to substitute brown or 2.3% polished rice if affordable after the taste tests and education on nutritional and health benefits of whole grains. Conclusion While most consumers’ preferred polished white rice, education regarding health benefits may help this population switch to brown or under milled rice. Cooking quality and appearance of the grains were perceived as the most important factors to consider when purchasing rice among Chennai urban adults. PMID:24015699
NASA Astrophysics Data System (ADS)
Beyhaghi, Maryam; Kiani-Rashid, Ali-Reza; Kashefi, Mehrdad; Khaki, Jalil Vahdati; Jonsson, Stefan
2015-07-01
Powder mixtures of Ni, NiO and Al are ball milled for 1 and 10 h. X-ray diffractometry and differential thermal analysis show that while ball milling for 1 h produced mechanically activated powder; 10 h ball milling produced NiAl and Al2O3 phases. Dense NiAl/Al2O3 composite coatings are formed on gray cast iron substrate by spark plasma sintering (SPS) technique. The effect of powder reactivity on microstructure, hardness and scratch hardness of NiAl/Al2O3 coatings after SPS is discussed. Results show that in the coating sample made of mechanically activated powder in situ synthesis of NiAl/Al2O3 composite coating is fulfilled and a thicker well-formed diffusion bond layer at the interface between coating and substrate is observed. The diffusion of elements across the bond layers and phase evolution in the bond layers were investigated. No pores or cracks were observed at the interface between coating layer and substrate in any of samples. Higher Vickers hardness and scratch hardness values in coating made of 10 h ball milled powder than in coating fabricated from 1 h ball milled powder are attributed to better dispersion of Al2O3 reinforcement particles in NiAl matrix and nano-crystalline structure of NiAl matrix. Scratched surface of coatings did not reveal any cracking or spallation at coating-substrate interface indicating their good adherence at test conditions.
Gas fluidized-bed stirred media mill
Sadler, III, Leon Y.
1997-01-01
A gas fluidized-bed stirred media mill is provided for comminuting solid ticles. The mill includes a housing enclosing a porous fluidizing gas diffuser plate, a baffled rotor and stator, a hollow drive shaft with lateral vents, and baffled gas exhaust exit ports. In operation, fluidizing gas is forced through the mill, fluidizing the raw material and milling media. The rotating rotor, stator and milling media comminute the raw material to be ground. Small entrained particles may be carried from the mill by the gas through the exit ports when the particles reach a very fine size.
Sod, Gary A; Riggs, Laura M; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S
2010-01-01
To compare in vitro monotonic biomechanical properties of an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP-TLS) with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (3-TLS) for the equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=15 pairs). For each forelimb pair, 1 PIP joint was stabilized with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion. Five matching pairs of constructs were tested in single cycle to failure under axial compression, 5 construct pairs were tested for cyclic fatigue under axial compression, and 5 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load under axial compression and torsion, single cycle to failure, of the DCP-TLS fixation were significantly greater than those of the 3-TLS fixation. Mean cycles to failure in axial compression of the DCP-TLS fixation was significantly greater than that of the 3-TLS fixation. The DCP-TLS was superior to the 3-TLS in resisting the static overload forces and in resisting cyclic fatigue. The results of this in vitro study may provide information to aid in the selection of a treatment modality for arthrodesis of the equine PIP joint.
Surface hardening of Al alloys through controlled ball-milling and sintering.
Kim, Seek Hyeoun; Kim, Yong Jin; Ahn, Jung-Ho
2012-07-01
One of the drawbacks of aluminum and its alloys is the lack of proper heat-treatment for surface-hardening. In the present work, a new and simple method of hardening the surface of aluminum and its alloys was developed. Low-energy ball-milling using specific process control agents (PCAs) was employed, using subsequent sintering in a controlled atmosphere. The PCAs in the present work were very effective both for milling and the formation of hard nanocrystalline dispersoids during sintering. The residual oxygen in a sintering atmosphere also played an important role in the formation of AIN or Al-O-N dispersoids. Through the proper control of the processing atmosphere and PCAs, the hardness and thickness of the hardened layers could be adjusted. The results of the wear test showed that the present aluminum alloys can be effectively utilized as light-weight components with a good wear resistance. Furthermore, the present method involves a simple forming process of die-compaction and sintering.
The robust design for improving crude palm oil quality in Indonesian Mill
NASA Astrophysics Data System (ADS)
Maretia Benu, Siti; Sinulingga, Sukaria; Matondang, Nazaruddin; Budiman, Irwan
2018-04-01
This research was conducted in palm oil mill in Sumatra Utara Province, Indonesia. Currently, the main product of this mill is Crude Palm Oil (CPO) and hasn’t met the expected standard quality. CPO is the raw material for many fat derivative products. The generally stipulated quality criteria are dirt count, free fatty acid, and moisture of CPO. The aim of this study is to obtain the optimal setting for factor’s affect the quality of CPO. The optimal setting will result in an improvement of product’s quality. In this research, Experimental Design with Taguchi Method is used. Steps of this method are identified influence factors, select the orthogonal array, processed data using ANOVA test and signal to noise ratio, and confirmed the research using Quality Loss Function. The result of this study using Taguchi Method is to suggest to set fruit maturity at 75.4-86.9%, digester temperature at 95°C and press at 21 Ampere to reduce quality deviation until 42.42%.
Advanced oxidation treatment of pulp mill effluent for TOC and toxicity removals.
Catalkaya, Ebru Cokay; Kargi, Fikret
2008-05-01
Pulp mill effluent was treated by different advanced oxidation processes (AOPs) consisting of UV, UV/H2O2, TiO2-assisted photo-catalysis (UV/TiO2) and UV/H2O2/TiO2 in lab-scale reactors for total organic carbon (TOC) and toxicity removals. Effects of some operating parameters such as the initial pH, oxidant and catalyst concentrations on TOC and toxicity removals were investigated. Almost every method resulted in some degree of TOC and toxicity removal from the pulp mill effluent. However, the TiO2-assisted photo-catalysis (UV/TiO2) resulted in the highest TOC and toxicity removals under alkaline conditions when compared with the other AOPs tested. Approximately, 79.6% TOC and 94% toxicity removals were obtained by the TiO2-assisted photo-catalysis (UV/TiO2) with a titanium dioxide concentration of 0.75gl(-1) at pH 11 within 60min.
Zhou, Guoqiang; Chen, Ziwen; Fang, Fei; He, Yuefeng; Sun, Haili; Shi, Huixiang
2015-09-01
For the paper industry, the disposal and management of the yielded sludge are a considerable challenge. In our work, the paper mill sludge-derived magnetically separable heterogeneous catalyst (PMS-Fe-380) was prepared easily through a facile synthesis method. The morphology and structure of PMS-Fe-380 were fully characterized by means of X-ray diffraction, Fourier transform infrared spectroscopy, scanning electron microscopy, and Brunauer-Emmet-Teller analysis. The catalytic activity of PMS-Fe-380 was evaluated by degradation of Methylene Blue (MB). The reusability and stability of PMS-Fe-380 were evaluated in five repeated runs, which suggested that PMS-Fe-380 manifested excellent stability of catalytic activity. Moreover, leaching tests indicated that the leached iron is negligible (<0.5mg/L). This study provides an alternative environmentally friendly reuse method for paper mill sludge and a novel catalyst PMS-Fe-380 that can be considered as a promising heterogeneous Fenton-like catalyst. Copyright © 2015. Published by Elsevier B.V.
Nakamura, Takashi; Usami, Hirofumi; Ohnishi, Hiroshi; Nishida, Hisataka; Tang, Xuehua; Wakabayashi, Kazumichi; Sekino, Tohru; Yatani, Hirofumi
2012-02-03
The aim of this study was to determine the machinability of new silica-doped Y-TZP by CAD/CAM and the resistance to low temperature degradation of the milled sample by comparing with a commercial HIP type Y-TZP material. The copings could be milled from silica-doped Y-TZP blocks without chipping, and there was no significant difference between the two types of Y-TZP materials in either the marginal or the inner gap between the abutment and the coping. After aging, the monoclinic content in the commercial Y-TZP copings increased from 25% before testing to 65%, while that of silica-doped Y-TZP copings slightly increased from 23% to 30%. The silica-doped Y-TZP copings did not have any significant difference in fracture load in a comparison between the control group and the aging group, while the commercial Y-TZP copings had a significantly lower fracture load for the aging group than for the control group.
Chemical, rheological and bread making characteristics of bran duster flours from roller flourmills.
Sakhare, Suresh D; Indrani, D; Inamdar, Aashitosh A; Gaikwad, Shwetha B; Rao, G Venkateswara
2014-10-01
Bran dusters are used in the wheat flour milling process to increase flour extraction rate. Chemical, rheological and bread characteristics of bran duster flours (BDR1, BDR2, BDR3) and straight run flour (SRF) obtained from two commercial roller flour mills were analyzed. Important chemical characteristics such as ash, dry gluten content, sedimentation value, damaged starch and falling number of bran duster flours were determined. Rheological behavior was tested using farinograph and alveograph equipments. The results showed an increase in ash, dry gluten content and Zeleny's sedimentation value for bran duster flours compared to SRF. Rheological characteristics indicated higher farinograph dough development time and stability values for bran duster flours. Alveograph characteristics indicated higher extensibility and lower elasticity values for bran duster flours. Over all quality score of bread for BDR1 from A and B roller flour mills ranged from 73.4 to 74.7, BDR2 (79-81.8), BDR3 (69-70.4) as against SRF (85.4-86.3).
NASA Technical Reports Server (NTRS)
Baker, G. R.; Fethe, T. P.
1975-01-01
Research in the application of remotely sensed data from LANDSAT or other airborne platforms to the efficient management of a large timber based forest industry was divided into three phases: (1) establishment of a photo/ground sample correlation, (2) investigation of techniques for multi-spectral digital analysis, and (3) development of a semi-automated multi-level sampling system. To properly verify results, three distinct test areas were selected: (1) Jacksonville Mill Region, Lower Coastal Plain, Flatwoods, (2) Pensacola Mill Region, Middle Coastal Plain, and (3) Mississippi Mill Region, Middle Coastal Plain. The following conclusions were reached: (1) the probability of establishing an information base suitable for management requirements through a photo/ground double sampling procedure, alleviating the ground sampling effort, is encouraging, (2) known classification techniques must be investigated to ascertain the level of precision possible in separating the many densities involved, and (3) the multi-level approach must be related to an information system that is executable and feasible.
Black liquor gasification integrated in pulp and paper mills: A critical review.
Naqvi, M; Yan, J; Dahlquist, E
2010-11-01
Black liquor gasification (BLG) has potential to replace a Tomlinson recovery boiler as an alternative technology to increase safety, flexibility and energy efficiency of pulp and paper mills. This paper presents an extensive literature review of the research and development of various BLG technologies over recent years based on low and high temperature gasification that include SCA-Billerud process, Manufacturing and Technology Conversion International (MTCI) process, direct alkali regeneration system (DARS), BLG with direct causticization, Chemrec BLG system, and catalytic hydrothermal BLG. A few technologies were tested on pilot scale but most of them were abandoned due to technical inferiority and very fewer are now at commercial stage. The drivers for the commercialization of BLG enabling bio-refinery operations at modern pulp mills, co-producing pulp and value added energy products, are discussed. In addition, the potential areas of research and development in BLG required to solve the critical issues and to fill research knowledge gaps are addressed and highlighted. Copyright 2010 Elsevier Ltd. All rights reserved.
Analysis of Nonlinear Insertion Loss of Hearing Protection Devices using an Acoustic Test Fixture
2015-09-01
USAARL Report No. 2016-05 Analysis of Nonlinear Insertion Loss of Hearing Protection Devices using an Acoustic Test Fixture By Robert Williams1...through circuitry. Talk through circuits use electro- acoustic transducers to pass ambient sounds through the protector. When the circuitry detects...the SPL of the acoustic insult. If the protective capacity is variable, it should be accounted for in the selection of appropriate HPDs. REAT
Investigating Delamination Migration in Composite Tape Laminates
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.; DeCarvalho, Nelson V.
2014-01-01
A modification to a recently developed test specimen designed to investigate migration of a delamination between neighboring ply interfaces in tape laminates is presented. The specimen is a cross-ply laminated beam consisting of 40 plies with a polytetrafluoroethylene insert spanning part way along its length. The insert is located between a lower 0-degree ply (specimen length direction) and a stack of four 90-degree plies (specimen width direction). The modification involved a stacking sequence that promotes stable delamination growth prior to migration, and included a relocation of the insert from the specimen midplane to the interface between plies 14 and 15. Specimens were clamped at both ends onto a rigid baseplate and loaded on their upper surface via a piano hinge assembly, resulting in a predominantly flexural loading condition. Tests were conducted with the load-application point positioned at various locations along a specimen's span. This position affected the sequence of damage events during a test.
Santos, R L P; Silva, F S; Nascimento, R M; Souza, J C M; Motta, F V; Carvalho, O; Henriques, B
2016-07-01
The purpose of this study was to evaluate the shear bond strength of veneering feldspathic porcelain to zirconia substrates modified by CNC-milling process or by coating zirconia with a composite interlayer. Four types of zirconia-porcelain interface configurations were tested: RZ - porcelain bonded to rough zirconia substrate (n=16); PZ - porcelain bonded to zirconia substrate with surface holes (n=16); RZI - application of a composite interlayer between the veneering porcelain and the rough zirconia substrate (n=16); PZI - application of a composite interlayer between the porcelain and the zirconia substrate treated by CNC-milling (n=16). The composite interlayer was composed of zirconia particles reinforced porcelain (30%, vol%). The mechanical properties of the ceramic composite have been determined. The shear bond strength test was performed at 0.5mm/min using a universal testing machine. The interfaces of fractured and untested specimens were examined by FEG-SEM/EDS. Data was analyzed with Shapiro-Wilk test to test the assumption of normality. The one-way ANOVA followed by Tukey HSD multiple comparison test was used to compare shear bond strength results (α=0.05). The shear bond strength of PZ (100±15MPa) and RZI (96±11MPa) specimens were higher than that recorded for RZ (control group) specimens (89±15MPa), although not significantly (p>0.05). The highest shear bond strength values were recorded for PZI specimens (138±19MPa), yielding a significant improvement of 55% relative to RZ specimens (p<0.05). This study shows that it is possible to highly enhance the zirconia-porcelain bond strength - even by ~55% - by combining surface holes in zirconia frameworks and the application of a proper ceramic composite interlayer. Copyright © 2016 Elsevier Ltd. All rights reserved.
2. RW Meyer Sugar Mill: 18761899. Threeroll sugar mill, oneton ...
2. RW Meyer Sugar Mill: 1876-1899. Three-roll sugar mill, one-ton daily processing capacity. Manufactured by Edwin Maw, Liverpool, England, ca. 1855-1870. View: Top roll and one bottom roll, mill housing or cheeks, and spur pinion gears. The broken projection on the mill beside the bottom roll indicates the location of the cane tray. The cane juice crushed from the cane flowed into the juice tray below the bottom rolls. It then flowed into a wooden gutter and through a short tunnel in the mill's masonry enclosure and on to the boiling house for further processing. The opening at the base of the masency wall (In the photograph) is where the gutter ran from the mill to the boiling house. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI
NASA Technical Reports Server (NTRS)
Bateman, M. G.; Stewart, M. F.; Blakeslee, R. J.; Podgorny, s. J.; Christian, H. J.; Mach, D. M.; Bailey, J. C.; Daskar, D.
2006-01-01
This paper reports on a new generation of aircraft-based rotating-vane style electric field mills designed and built at NASA's Marshall Spaceflight Center. The mills have individual microprocessors that digitize the electric field signal at the mill and respond to commands from the data system computer. The mills are very sensitive (1 V/m per bit), have a wide dynamic range (115 dB), and are very low noise (+/-1 LSB). Mounted on an aircraft, these mills can measure fields from +/-1 V/m to +/-500 kV/m. Once-per-second commanding from the data collection computer to each mill allows for precise timing and synchronization. The mills can also be commanded to execute a self-calibration in flight, which is done periodically to monitor the status and health of each mill.
40 CFR 406.50 - Applicability; description of the normal rice milling subcategory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... normal rice milling subcategory. 406.50 Section 406.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GRAIN MILLS POINT SOURCE CATEGORY Normal Rice Milling Subcategory § 406.50 Applicability; description of the normal rice milling subcategory. The...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false Milling. 3596.1 Section 3596.1 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT... OPERATIONS Waste From Mining or Milling § 3596.1 Milling. The operator/lessee shall conduct milling...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false Milling. 3596.1 Section 3596.1 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT... OPERATIONS Waste From Mining or Milling § 3596.1 Milling. The operator/lessee shall conduct milling...
Quench Module Insert (QMI) and the Diffusion Module Insert (DMI) Furnace Development
NASA Technical Reports Server (NTRS)
Crouch, Myscha R.; Carswell, William E.; Farmer, Jeff; Rose, Fred; Tidwell, Paul H., II
2000-01-01
The Quench Module Insert (QMI) and the Diffusion Module Insert (DMI) are microgravity furnaces under development at Marshall Space Flight Center. The furnaces are being developed for the first Materials Science Research Rack (MSRR-1) of the Materials Science Research Facility (MSRF), one of the first International Space Station (ISS) scientific payloads. QMI is a Bridgman furnace with quench capability for studying interface behavior during directional solidification of metallic and alloy materials. DMI will be a Bridgman-Stockbarger furnace to study diffusion processes in semiconductors. The design for each insert, both QMI and DMI, is driven by specific science, operations and safety requirements, as well as by constraints arising from resource limitations, such as volume, mass and power. Preliminary QMI analysis and testing indicates that the design meets these requirements.
Stress corrosion crack initiation of alloy 600 in PWR primary water
Zhai, Ziqing; Toloczko, Mychailo B.; Olszta, Matthew J.; ...
2017-04-27
Stress corrosion crack (SCC) initiation of three mill-annealed alloy 600 heats in simulated pressurized water reactor primary water has been investigated using constant load tests equipped with in-situ direct current potential drop (DCPD) measurement capabilities. SCC initiation times were greatly reduced by a small amount of cold work. Shallow intergranular attack and/or cracks were found on most high-energy grain boundaries intersecting the surface with only a small fraction evolving into larger cracks and intergranular SCC growth. Crack depth profiles were measured and related to DCPD-detected initiation response. Lastly, we discuss processes controlling the SCC initiation in mill-annealed alloy 600.
2011-11-01
milled for 12 h. Typical weight loss of the SiC grinding media after milling was 0.2 mg (0.2 wt% of the total batch). The powders were sieved...10-mL Ca -stabilized ZrO2 crucible; 95% ZrO2 and 4±1% Ca ). Direct electrical resistance heating was controlled by the power output of an AC power...furnace heating has been described previously by the authors, which was shown to contain Al and Ca as major impurities [14]. Additionally, HfSiO4 (with
NASA Astrophysics Data System (ADS)
Anan, Ruito; Matsuoka, Hironori; Ono, Hajime; Ryu, Takahiro; Nakae, Takashi; Shuto, Schuichi; Watanabe, Suguru; Sato, Yuta
2017-04-01
This study examined the improvements to the tool life and finished surface roughness by using water-miscible cutting fluids in carbon fiber reinforced plastics end milling. In cutting tests, it was found that the use of emulsion type, soluble type, and solution type cutting fluids improved tool life compared with the case of dry cutting. Specifically, significant differences in tool life were observed at a high cutting speed of 171 m/min. In addition, the finished surface exhibited a low level of roughness when the solution type cutting fluid was used, regardless of the cutting speed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Otero, A.R.
1959-01-01
The behavior of uranium mineral from Venta de Cardena in a spiral classifier which operates in a closed system with a ball mill was studied to obtain data for the design of a milling-classification system with a production capacity of 200 tons per day with a particle size less than 0.417 mm. The characteristics of such a system, the problems in normal operation, the inconveriences which these cause, and their solution were investigated. Correlations between these tests and the results obtained with long glass tubes are presented. (J.S.R.)
A test of the AdS/CFT duality on the Coulomb branch
NASA Astrophysics Data System (ADS)
Costa, M. S.
2000-06-01
We consider the /N=4 /SU(N) Super Yang Mills theory on the Coulomb branch with gauge symmetry broken to S(U(N1)×U(N2)). By integrating the W particles, the effective action near the IR SU(Ni) conformal fixed points is seen to be a deformation of the Super Yang Mills theory by a non-renormalized, irrelevant, dimension 8 operator. The correction to the two-point function of the dilaton field dual operator near the IR is related to a three-point function of chiral primary operators at the conformal fixed points and agrees with the classical gravity prediction, including the numerical factor.
Characterization of BOR-60 Irradiated 14YWT-NFA1 Tubes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saleh, Tarik A.; Maloy, Stuart Andrew; Aydogan, Eda
2017-02-15
Tubes of FCRD 14YWT-NFA1 Alloy were placed in the BOR-60 reactor and irradiated under a fast flux neutron environment to two conditions: 7 dpa at 360-370 °C and 6 dpa at 385-430 °C. Small sections of the tube were cut and sent to UC Berkeley for nanohardness testing and focused ion beam (FIB) milling of TEM specimens. FIB specimens were sent back to LANL for final FIB milling and TEM imaging. Hardness data and TEM images are presented in this report. This is the first fast reactor neutron irradiated information on the 14YWT-NFA1 alloy.
Stress corrosion crack initiation of alloy 600 in PWR primary water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhai, Ziqing; Toloczko, Mychailo B.; Olszta, Matthew J.
Stress corrosion crack (SCC) initiation of three mill-annealed alloy 600 heats in simulated pressurized water reactor primary water has been investigated using constant load tests equipped with in-situ direct current potential drop (DCPD) measurement capabilities. SCC initiation times were greatly reduced by a small amount of cold work. Shallow intergranular attack and/or cracks were found on most high-energy grain boundaries intersecting the surface with only a small fraction evolving into larger cracks and intergranular SCC growth. Crack depth profiles were measured and related to DCPD-detected initiation response. Lastly, we discuss processes controlling the SCC initiation in mill-annealed alloy 600.
1982-06-01
7 1l41498 EFORE SMITH’S MILL ARCHAEOLOGICAL AND GEOLOGICAL INVESTIGATIONS SM TVI lU GA! CONSULTANTS INC N )NROEVIL EPA W P MCHUGH E AL JUN 82 IN...8217 Q . 6w0 .-y, By Wilia P. Mcug /- .3- 0’ 84 11 01 0 • .,1. *... ... S 0* ** .. 0. -. DT CBy William P. McHugh AELECTEII George D. Gardner NOV’ n8jI...step trench. William McHugh was present at least half of each day and excavated one 1 m x 1 m test unit and a step trench; he also photographed the
Hiraki, Takao; Kamegawa, Tetsushi; Matsuno, Takayuki; Sakurai, Jun; Kirita, Yasuzo; Matsuura, Ryutaro; Yamaguchi, Takuya; Sasaki, Takanori; Mitsuhashi, Toshiharu; Komaki, Toshiyuki; Masaoka, Yoshihisa; Matsui, Yusuke; Fujiwara, Hiroyasu; Iguchi, Toshihiro; Gobara, Hideo; Kanazawa, Susumu
2017-11-01
Purpose To evaluate the accuracy of the remote-controlled robotic computed tomography (CT)-guided needle insertion in phantom and animal experiments. Materials and Methods In a phantom experiment, 18 robotic and manual insertions each were performed with 19-gauge needles by using CT fluoroscopic guidance for the evaluation of the equivalence of accuracy of insertion between the two groups with a 1.0-mm margin. Needle insertion time, CT fluoroscopy time, and radiation exposure were compared by using the Student t test. The animal experiments were approved by the institutional animal care and use committee. In the animal experiment, five robotic insertions each were attempted toward targets in the liver, kidneys, lungs, and hip muscle of three swine by using 19-gauge or 17-gauge needles and by using conventional CT guidance. The feasibility, safety, and accuracy of robotic insertion were evaluated. Results The mean accuracies of robotic and manual insertion in phantoms were 1.6 and 1.4 mm, respectively. The 95% confidence interval of the mean difference was -0.3 to 0.6 mm. There were no significant differences in needle insertion time, CT fluoroscopy time, or radiation exposure to the phantom between the two methods. Effective dose to the physician during robotic insertion was always 0 μSv, while that during manual insertion was 5.7 μSv on average (P < .001). Robotic insertion was feasible in the animals, with an overall mean accuracy of 3.2 mm and three minor procedure-related complications. Conclusion Robotic insertion exhibited equivalent accuracy as manual insertion in phantoms, without radiation exposure to the physician. It was also found to be accurate in an in vivo procedure in animals. © RSNA, 2017 Online supplemental material is available for this article.
The influence of a small insert, in the footbed of a shoe, upon plantar pressure distribution.
Burgess, S; Jordan, C; Bartlett, RM
1997-04-01
INTRODUCTION:: A recent development in plantar pressure distribution research, has been the study of the effects of sensory input on pressure distribution. It has been suggested that proprioceptive and exteroceptive information received from the plantar surface of the foot plays an important role in adapting to high pressures in shoes. Robbins and Gouw (1991) suggested that surface irregularities should be added to the insoles of running shoes to gain correct sensory input. Hayda et al. (1994) found that placing a pad proximal to the metatarsal heads produced significant reductions in forefoot plantar pressures around the first and second metatarsal heads. A development by Villeneuve (1993), 'La Posteropodle', utilized a small insert to maintain postural equilibrium, by stimulating the mechanoreceptors in the plantar surface of the foot. The aim of this study was to measure changes in plantar pressure distribution using a small circular insert. METHODS:: Ten non-pathological male subjects were tested whilst walking, after one day of wearing a pair of oxfords (hard) and running shoes (soft), containing an insert of 4 mm in height placed on a 0.8 mm EVA insole. The foot was split into five sections: (1) midfoot, (2) first metatarsal head, (3) 2nd and 3rd metatarsal heads, (4) 4th and 5th metatarsal heads, (5) the phalanges. A PEDAR system (Novel GmbH) was used to collect in-shoe plantar pressure data, with data collections at the beginning and end of a working day. Subjects were tested under two conditions: (1) the insert 5 mm proximal to the metatarsal heads, between the 2nd and 3rd heads, (2) a control, with no insert. RESULTS:: Preliminary results indicate that whilst wearing a hard shoe the insert had the effect of shifting peak pressures from the first metatarsal head, to the area of the second and third metatarsal heads. Peak pressures were found to be lower with the insert present. This has not yet been tested for significance. With the running shoe there appeared to be no significant differences between conditions with and without the insert. There were also no differences between the beginning and end of the day, for both shoe types. DISCUSSION:: From the results it appears that the insert is successful in both shifting peak pressures from the medial to the lateral forefoot, whilst reducing peak pressures simultaneously. This was only evident in the hard shoe condition however, suggesting that the footbed of the running shoe was perhaps too soft to allow the insert to influence sensory input sufficiently. These findings indicate that there may be implications for the use of small orthotics. Further study is required, however, to fully substantiate this hypothesis.
NASA Astrophysics Data System (ADS)
Pieńko, Michał; Błazik-Borowa, Ewa
2018-01-01
This paper presents the problem of comparing the results of computer simulations with the results of laboratory tests. The subject of the study was the insert-type joint of scaffolding loaded with a bending moment. The research was carried out on the real elements of the scaffolding. Due to the complexity of the connection different friction coefficients and depths of wedge insertion were taken into account in the analysis. The aim of conducting the series of analyses was to determine the sensitivity of the model to the mentioned characteristics. Since laboratory tests were carried out on the real samples, there were no preparations of surface involved in the load transfer. This approach caused many problems with the clear definition of the nature of work of individual node elements during the load. The analysis consist of two stages: the stage in which the connection is defined (the wedge is inserted into the rosette), and the loading stage (the node is loaded by the bending moment).
Nawabi, Danyal H.; Imhauser, Carl; Tucker, Scott; Nguyen, Joseph; Wickiewicz, Thomas L.; Pearle, Andrew
2014-01-01
Objectives: Histological studies have shown that the ACL has a direct and indirect insertion on the femur [1]. The direct insertion is located along the lateral intercondylar ridge and the indirect insertion is located ‘lower’ on the lateral wall of the notch. The trend towards anatomic ACL reconstruction using the anteromedial (AM) portal technique has resulted in ‘lower’ non-isometric femoral tunnel positions and increased graft failures [2]. To our knowledge, the load transfer properties of the direct and indirect ACL insertions have not been studied. This information may help in understanding the increased failures reported with AM portal drilling. The purpose of this study was, 1) to compare the load transferred across the native ACL at the direct and indirect femoral insertions and, 2) to determine the strain behavior of ACL grafts placed at different tunnel locations within the direct and indirect insertions. Methods: Ten fresh-frozen cadaveric knees (mean age, 52.5 years; range, 29-65) were mounted to a six degree of freedom robot. A 134N anterior load at 30 and 90° flexion and a combined valgus (8Nm) and internal (4Nm) rotational moment at 15° flexion were applied. The ACL was subsequently sectioned at the femoral footprint by detaching either the direct or indirect insertion (partially sectioned state), followed by the remainder of the ACL (completely sectioned state) (Figure 1). The kinematics of the intact knee were replayed after each stage of sectioning to determine the loads transferred across the direct and indirect ACL fibers. Loads were expressed as a percentage of the total load borne by the ACL. Strain behaviour was tested by generating 3D models of the femur and tibia from CT scans of each knee. Three tunnel locations (anteromedial bundle [AM], center [C], posterolateral bundle [PL]) each were selected for the direct and indirect insertions and a virtual ACL graft was inserted. The isometry of the virtual graft was calculated through a flexion path of 0 to 90°. Results: Under an anterior tibial load at 30° flexion, the direct insertion carried 83.9% of the total ACL load compared to 16.1% in the indirect insertion (p<0.001). The direct insertion also carried more load at 90° flexion (95.2% vs 4.8%; p<0.001). Under a combined rotatory load at 15° flexion, the direct insertion carried 84.2% of the total ACL load compared to 15.8% in the indirect insertion (p<0.001). A virtual ACL graft placed at the AM position in the direct insertion demonstrated the best strain behaviour with a mean 10.9% change in length. This value was significantly lower (p<0.001) than the isometry at all 3 tunnel positions in the indirect insertion (AM = 18.5%; C = 24.9%; PL = 30.9%). Conclusion: Fibers in the direct insertion of the ACL carry more load than fibers in the indirect insertion. Virtual ACL grafts placed in the ‘higher’ direct location are more isometric than in the ‘lower’ indirect location during range of motion testing. Clinical Relevance: ‘Low’ ACL grafts in the indirect ACL insertion, resulting from AM portal drilling techniques, may experience higher loads in-vivo due to unfavorable biomechanics. With the current shift towards anatomic ACL reconstruction, it may be beneficial to create a ‘higher’ femoral tunnel within the direct insertion at the lateral intercondylar ridge. This position remains anatomical but may also be biomechanically favorable.
Peak insertion torque values of five mini-implant systems under different insertion loads.
Quraishi, Erma; Sherriff, Martyn; Bister, Dirk
2014-06-01
To assess the effect of 1 and 3 kg insertion load on five makes of self-drilling mini-implants on peak insertion torque values to establish risk factors involved in the fracture of mini-implants. Two different loads were applied during insertion of 40 mini-implants from five different manufacturers (Dual Top(™) (1·6×8 mm), Infinitas(™) (1·5×9 mm), Ortho Easy(™) (1·7×8 mm), Spider Screw(™) (1·5×8 mm) and Vector TAS(™) (1·4×8 mm)) into acrylic blocks at 8 rev/min utilizing a Motorized Torque Measurement Stand. Peak insertion torque values for both loads were highest for Vector TAS followed by Ortho Easy and Dual Top and were nearly three times higher than Infinitas (original version) and Spider Screws(TM). The log-rank test showed statistically significant differences for both loads for Vector TAS, Ortho Easy and Spider Screws. Unlike other designs tested, both tapered mini-implant designs (Spider Screw and Infinitas) showed a tendency to buckle in the middle of the body but fractured at the tip. Non-tapered mini-implants fractured at significantly higher torque values compared to tapered designs under both loads. Increased pressure resulted in slightly higher maximum torque values at fracture for some of the mini-implant designs, although this is unlikely to be of clinical relevance. Tripling insertion pressure from 1 to 3 kg increased the risk of bending tapered mini-implants before fracture. © 2014 British Orthodontic Society.
Does hard insertion and space improve shock absorption ability of mouthguard?
Takeda, Tomotaka; Ishigami, Keiichi; Handa, Jun; Naitoh, Kaoru; Kurokawa, Katsuhide; Shibusawa, Mami; Nakajima, Kazunori; Kawamura, Shintaro
2006-04-01
Mouthguards are expected to reduce sports-related orofacial injuries. Numerous studies have been conduced to improve the shock absorption ability of mouthguards using air cells, sorbothane, metal wire, or hard material insertion. Most of these were shown to be effective; however, the result of each study has not been applied to clinical use. The aim of this study was to develop mouthguards that have sufficient prevention ability and ease of clinical application with focus on a hard insertion and space. Ethylene vinyl acetate (EVA) mouthguard blank used was Drufosoft and the acrylic resin was Biolon (Dreve-Dentamid GMBH, Unna, Germany). Three types of mouthguard samples tested were constructed by means of a Dreve Drufomat (Type SO, Dreve-Dentamid) air pressure machine: the first was a conventional laminated type of EVA mouthguard material; the second was a three layer type with acrylic resin inner layer (hard-insertion); the third was the same as the second but with space that does not come into contact with tooth surfaces (hard + space). As a control, without any mouthguard condition (NOMG) was measured. A pendulum type impact testing machine with interchangeable impact object (steel ball and baseball) and dental study model (D17FE-NC.7PS, Nissin, Tokyo, Japan) with the strain gages (KFG-1-120-D171-11N30C2: Kyowa, Tokyo, Japan) applied to teeth and the accelerometer to the dentition (AS-A YG-2768 100G, Kyowa) were used to measure transmitted forces. Statistical analysis (anova, P < 0.01) showed significant differences among four conditions of NOMG and three different mouthguards in both objects and sensor. About acceleration: in a steel ball which was a harder impact object, shock absorption ability of about 40% was shown with conventional EVA and hard-insertion and about 50% with hard + space. In a baseball that was softer compared with steel ball, a decrease rate is smaller, reduction (EVA = approximately 4%, hard-insertion = approximately 12%, hard + space = approximately 25%) was admitted in the similar order. A significant difference was found with all the combinations except for between EVA and hard-insertion with steel ball (Tukey test). About distortion: both buccal and lingual, distortions had become small in order of EVA, hard-insertion, and hard + space, too. The decrease rate is larger than acceleration, EVA = approximately 47%, hard-insertion = 80% or more, and hard +space = approximately 98%, in steel ball. EVA = approximately 30%, hard-insertion = approximately 75%, and hard + space = approximately 98% in baseball. And a significant difference was found with all the combinations (Tukey test). Especially, hard + space has decreased the distortion of teeth up to several percentages. Acceleration of the maxilla and distortions of the tooth became significantly smaller when wearing any type of mouthguard, in both impact objects. But the effect of mouthguard was clearer in the distortion of the tooth and with steel ball. Considering the differences of mouthguards, the hard-insertion and the hard + space had significantly greater buffer capacity than conventional EVA. Furthermore, hard + space shows quite high shock absorption ability in the tooth distortion. Namely, hard + space has decreased the distortion of teeth up to several percentages in both impact objects.
21 CFR 515.10 - Medicated feed mill license applications.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Medicated feed mill license applications. 515.10... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS MEDICATED FEED MILL LICENSE Applications § 515.10 Medicated feed mill license applications. (a) Medicated feed mill license applications (Forms FDA 3448) may...
7 CFR 868.314 - Grade designation and other certificate information.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Milled Rice Principles Governing Application of Standards § 868.314 Grade designation and other certificate information. (a) Milled rice. The grade designation for all classes of Milled rice shall be... Milled rice information. For the class Mixed Milled rice, the following information shall be included in...
7 CFR 868.314 - Grade designation and other certificate information.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Milled Rice Principles Governing Application of Standards § 868.314 Grade designation and other certificate information. (a) Milled rice. The grade designation for all classes of Milled rice shall be... Milled rice information. For the class Mixed Milled rice, the following information shall be included in...
68. VIEW OF MILLING FLOOR FROM SOUTHEAST. SECONDARY MILL AND ...
68. VIEW OF MILLING FLOOR FROM SOUTHEAST. SECONDARY MILL AND CLASSIFIER AT MIDDLE LEFT. PRIMARY MILL SURGE TANK AND LAUNDERS AT MIDDLE BOTTOM. STAIR TO TROJAN CLASSIFIER LEVEL BEHIND CRANE BENT, UPPER RIGHT. PAIRED PIPES FROM PRIMARY PULP PUMPS TO PRIMARY THICKENERS RISE VERTICALLY AT MIDDLE RIGHT AND RUN HORIZONTALLY ACROSS TOP OF VIEW. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD
168. VIEW OF MILLING FLOOR FROM SOUTHEAST. SECONDARY MILL AND ...
168. VIEW OF MILLING FLOOR FROM SOUTHEAST. SECONDARY MILL AND CLASSIFIER AT MIDDLE LEFT. PRIMARY MILL SURGE TANK AND LAUNDERS AT MIDDLE BOTTOM. STAIR TO TROJAN CLASSIFIER LEVEL BEHIND CRANE BENT, UPPER RIGHT. PAIRED PIPES FROM PRIMARY PULP PUMPS TO PRIMARY THICKENERS RISE VERTICALLY AT MIDDLE RIGHT AND RUN HORIZONTALLY ACROSS TOP OF VIEW - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD
Lebon, Nicolas; Tapie, Laurent; Duret, Francois; Attal, Jean-Pierre
2016-01-01
The dental milling machine is an important device in the dental CAD/CAM chain. Nowadays, dental numerical controlled (NC) milling machines are available for dental surgeries (chairside solution). This article provides a mechanical engineering approach to NC milling machines to help dentists understand the involvement of technology in digital dentistry practice. First, some technical concepts and definitions associated with NC milling machines are described from a mechanical engineering viewpoint. The technical and economic criteria of four chairside dental NC milling machines that are available on the market are then described. The technical criteria are focused on the capacities of the embedded technologies of these milling machines to mill both prosthetic materials and types of shape restorations. The economic criteria are focused on investment costs and interoperability with third-party software. The clinical relevance of the technology is assessed in terms of the accuracy and integrity of the restoration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Derek; Mutanga, Theodore
Purpose: An end-to-end testing methodology was designed to evaluate the overall SRS treatment fidelity, incorporating all steps in the linac-based frameless radiosurgery treatment delivery process. The study details our commissioning experience of the Steev (CIRS, Norfolk, VA) stereotactic anthropomorphic head phantom including modification, test design, and baseline measurements. Methods: Repeated MR and CT scans were performed with interchanging inserts. MR-CT fusion accuracy was evaluated and the insert spatial coincidence was verified on CT. Five non-coplanar arcs delivered a prescription dose to a 15 mm spherical CTV with 2 mm PTV margin. Following setup, CBCT-based shifts were applied as per protocol.more » Sequential measurements were performed by interchanging inserts without disturbing the setup. Spatial and dosimetric accuracy was assessed by a combination of CBCT hidden target, radiochromic film, and ion chamber measurements. To facilitate film registration, the film insert was modified in-house by etching marks. Results: MR fusion error and insert spatial coincidences were within 0.3 mm. Both CBCT and film measurements showed spatial displacements of 1.0 mm in similar directions. Both coronal and sagittal films reported 2.3 % higher target dose relative to the treatment plan. The corrected ion chamber measurement was similarly greater by 1.0 %. The 3 %/2 mm gamma pass rate was 99% for both films Conclusions: A comprehensive end-to-end testing methodology was implemented for our SRS QA program. The Steev phantom enabled realistic evaluation of the entire treatment process. Overall spatial and dosimetric accuracy of the delivery were 1 mm and 3 % respectively.« less
Barañao, P A; Hall, E R
2004-01-01
Activated Sludge Model No 3 (ASM3) was chosen to model an activated sludge system treating effluents from a mechanical pulp and paper mill. The high COD concentration and the high content of readily biodegradable substrates of the wastewater make this model appropriate for this system. ASM3 was calibrated based on batch respirometric tests using fresh wastewater and sludge from the treatment plant, and on analytical measurements of COD, TSS and VSS. The model, developed for municipal wastewater, was found suitable for fitting a variety of respirometric batch tests, performed at different temperatures and food to microorganism ratios (F/M). Therefore, a set of calibrated parameters, as well as the wastewater COD fractions, was estimated for this industrial wastewater. The majority of the calibrated parameters were in the range of those found in the literature.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jeoung Han; Byun, Thak Sang; Shin, Eunjoo
2015-08-17
Three oxide dispersion-strengthened (ODS) steels are produced in order to investigate the effect of the mechanical alloying (MA) temperature on the microstructural evolution and high temperature mechanical properties. The microstructural evolution with different MA conditions is examined using small angle neutron scattering. As the MA temperature decreases, the density of the nanoclusters below 10 nm increases and their mean diameter decreases. A low temperature during MA leads to a high strength in the compression tests performed at 500 *C; however, this effect disappears in testing at 900 *C. The milling process at *70 *C exhibits excellent high fracture toughness, whichmore » is better than the benchmark material 14YWT-SM10. However, the *150 *C milling process results in significantly worse fracture toughness properties. The reasons for this strong temperature dependency are discussed.« less
NASA Astrophysics Data System (ADS)
Lei, Chen; Pan, Zhang; Jianxiong, Chen; Tu, Yiliu
2018-04-01
The plasma brightness cannot be used as a direct indicator of ablation depth detection by femtosecond laser was experimentally demonstrated, which led to the difficulty of depth measurement in the maching process. The tests of microchannel milling on the silicon wafer were carried out in the micromachining center in order to obtain the influences of parameters on the ablation depth. The test results showed that the defocusing distance had no significant impact on ablation depth in LAV effective range. Meanwhile, the reason of this was explained in this paper based on the theoretical analysis and simulation calculation. Then it was proven that the ablation depth mainly depends on laser fluence, step distance and scanning velocity. Finally, a research was further carried out to study the laser parameters which relate with the microchannel ablation depth inside the quartz glass for more efficiency and less cost in processing by femtosecond laser.
Bending stiffness, torsional stability, and insertion force of cementless femoral stems.
Incavo, S J; Johnson, C C; Churchill, D L; Beynnon, B D
2001-04-01
In cementless total hip arthroplasty, increased femoral stem flexibility and decreased fracture propensity are desirable characteristics. The slotting and tapering of the stem have been introduced to achieve this. These features should not, however, be allowed to interfere with the ability of the distal stem to provide initial mechanical stability, especially under rotation. This study was done to investigate the ability of slotted and tapered stem designs to reduce stiffness and insertion force while still maintaining adequate torsional strength. The torsional strength, maximum insertion force, and insertional work of straight, slotted, and taper stems were measured by inserting each type into rigid polyurethane foam and torque testing to failure. Bending stiffness of each stem design was calculated using numerical methods. When compared to a straight stem, a unislot stem has similar torsional strength, maximum insertional force, and work of insertion. The bending stiffness is decreased by 19% to 82% depending on the bending direction. A trislot design decreased torque strength by 29%, maximal insertion force by 36%, and work by 11%. Bending stiffness was decreased by 74% and was not dependent on bending direction. A 0.5-mm taper decreased torque strength by 11% and insertional work by 14%. No difference was seen in maximum insertional force. We conclude that the design features studied (slots and taper) are effective in decreasing stem stiffness and reducing fracture propensity.
Hiebl, Bernhard; Lützow, Karola; Lange, Maik; Jung, Friedrich; Seifert, Barbara; Klein, Frank; Weigel, Thomas; Kratz, Karl; Lendlein, Andreas
2010-07-01
Most polymers used in clinical applications today are materials that have been developed originally for application areas other than biomedicine. Testing the cell- and tissue-compatibility of novel materials in vitro and in vivo is of key importance for the approval of medical devices and is regulated according to the Council Directive 93/42/EEC of the European communities concerning medical devices. In the standardized testing methods the testing sample is placed in commercially available cell culture plates, which are often made from polystyrene. Thus not only the testing sample itself influences cell behavior but also the culture vessel material. In order to exclude this influence, a new system for cell testing will be presented allowing a more precise and systematic investigation by preparing tailored inserts which are made of the testing material. Inserts prepared from polystyrene, polycarbonate and poly(ether imide) were tested for their cytotoxity and cell adherence. Furthermore a proof of principle concerning the preparation of inserts with a membrane-like surface structure and its surface modification was established. Physicochemical investigations revealed a similar morphology and showed to be very similar to the findings to analogous preparations and modifications of flat-sheet membranes. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Schulze, Jenny Jakobsson; Lundmark, Jonas; Garle, Mats; Skilving, Ilona; Ekström, Lena; Rane, Anders
2008-07-01
Testosterone abuse is conventionally assessed by the urinary testosterone/epitestosterone (T/E) ratio, levels above 4.0 being considered suspicious. The large variation in testosterone glucuronide (TG) excretion and its strong association with a deletion polymorphism in the uridine diphospho-glucuronosyl transferase (UGT) 2B17 gene challenge the accuracy of the T/E ratio test. Our objective was to investigate whether genotype-based cutoff values will improve the sensitivity and specificity of the test. This was an open three-armed comparative study. A total of 55 healthy male volunteers with either two, one, or no allele [insertion/insertion, insertion/deletion, or deletion/deletion (del/del)] of the UGT2B17 gene was included in the study. A single im dose of 500 mg testosterone enanthate was administered. Urinary excretion of TG after dose and the T/E ratio during 15 d were calculated. The degree and rate of increase in the TG excretion rate were highly dependent on the UGT2B17 genotype with a 20-fold higher average maximum increase in the insertion/insertion group compared with the del/del group. Of the del/del subjects, 40% never reached the T/E ratio of 4.0 on any of the 15 d after the dose. When differentiated cutoff levels for the del/del (1.0) and the other genotypes (6.0) were applied, the sensitivity increased substantially for the del/del group, and false positives in the other genotypes were eliminated. Consideration of the genetic variation in disposition of androgens will improve the sensitivity and specificity of the testosterone doping test. This is of interest not only for combating androgen doping in sports, but also for detecting and preventing androgen abuse in society.
Activity of Plodia interpunctella (Lepidoptera: Pyralidae) in and around flour mills.
Doud, C W; Phillips, T W
2000-12-01
Studies were conducted at two flour mills where male Indian meal moths, Plodia interpunctella (Hübner), were captured using pheromone-baited traps. Objectives were to determine the distribution of male P. interpunctella at different locations in and around the mills throughout the season, and to monitor moth activity before and after one of the mills was fumigated with methyl bromide to assess efficacy of treatment. Commercially available sticky traps baited with the P. interpunctella sex pheromone were placed at various locations outside and within the larger of the two mills (mill 1). Moths were captured inside mill 1 after methyl bromide fumigations. The highest numbers of P. interpunctella were caught outside the facility and at ground floor locations near outside openings. Additional traps placed in the rooms above the concrete stored-wheat silos at mill 1 during the second year captured more moths than did traps within the mill's production and warehouse areas. In another study, moths were trapped at various distances from a smaller flour mill (mill 2) to determine the distribution of moths outdoors relative to the mill. There was a negative correlation between moth capture and distance from the facility, which suggested that moth activity was concentrated at or near the flour mill. The effectiveness of the methyl bromide fumigations in suppressing moth populations could not be assessed with certainty because moths captured after fumigation may have immigrated from outside through opened loading bay warehouse doors. This study documents high levels of P. interpunctella outdoors relative to those recorded inside a food processing facility. Potential for immigration of P. interpunctella into flour mills and other stored product facilities from other sources may be greater than previously recognized. Moth entry into a food processing facility after fumigation is a problem that should be addressed by pest managers.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-11
... tests will help to ensure that control systems are maintained properly over time and a more rigorous... approach, industry is expected to save time in the performance test submittal process. Additionally this... pulping vent gas control at mills where the CCA approach would be adversely affected. Our revised cost...
Effects of Sibling Characteristics and Parental Values on Creative Interest and Achievement.
ERIC Educational Resources Information Center
Helson, Ravenna
In investigating patterns of family relationships conducive to creativity, several inventory-type personality tests and a questionnaire about family relationships and childhood interests were sent to 99 Mills College alumnae 5 years after their graduation and to the siblings of 51 of them. All had been tested, while seniors, for personality and…
Comparison of fiber orientation and tensile-stiffness orientation measurements in paper
David W. Vahey; John M. Considine; Andy Kahra; Mark Scotch
2008-01-01
We have had the opportunity to subject cross-machine paper strips from two mills to both ultrasound and optical "fiber-orientation" tests to examine the relationships between the results. Both determine an orientation angle, in degrees. Both measure sheet anisotropy as an MD/CD orientation ratio. The optical test has no counterpart to the ultrasonic...
Capabilities Report 2012, West Desert Test Center
2012-03-12
132 FT- IR Spectrometer...electronic system files, paper logs, production batch records, QA/QC data, and PCR data generated during a test. Data analysts also track and QC raw data...Advantage +SL bench-top freeze dryers achieve shelf temperatures as low as -57°C and condenser temperatures to -67°C. The bulk milling facility produces
Code of Federal Regulations, 2013 CFR
2013-07-01
... compliance requirements for new and existing sources? 63.11602 Section 63.11602 Protection of Environment... Requirements § 63.11602 What are the performance test and compliance requirements for new and existing sources... compounds of cadmium, chromium, lead, or nickel to a process vessel or to the grinding and milling equipment...
Code of Federal Regulations, 2012 CFR
2012-07-01
... compliance requirements for new and existing sources? 63.11602 Section 63.11602 Protection of Environment... Requirements § 63.11602 What are the performance test and compliance requirements for new and existing sources... compounds of cadmium, chromium, lead, or nickel to a process vessel or to the grinding and milling equipment...
Code of Federal Regulations, 2010 CFR
2010-07-01
... compliance requirements for new and existing sources? 63.11602 Section 63.11602 Protection of Environment... Requirements § 63.11602 What are the performance test and compliance requirements for new and existing sources... compounds of cadmium, chromium, lead, or nickel to a process vessel or to the grinding and milling equipment...
Code of Federal Regulations, 2014 CFR
2014-07-01
... compliance requirements for new and existing sources? 63.11602 Section 63.11602 Protection of Environment... Requirements § 63.11602 What are the performance test and compliance requirements for new and existing sources... compounds of cadmium, chromium, lead, or nickel to a process vessel or to the grinding and milling equipment...
Code of Federal Regulations, 2011 CFR
2011-07-01
... compliance requirements for new and existing sources? 63.11602 Section 63.11602 Protection of Environment... Requirements § 63.11602 What are the performance test and compliance requirements for new and existing sources... compounds of cadmium, chromium, lead, or nickel to a process vessel or to the grinding and milling equipment...
Demonstration of a silicon nitride attrition mill for production of fine pure Si and Si3N4 powders
NASA Technical Reports Server (NTRS)
Herbell, T. P.; Glasgow, T. K.; Orth, N. W.
1984-01-01
To avoid metallic impurities normally introduced by milling ceramic powders in conventional steel hardware, an attrition mill (high-energy stirred ball mill) was constructed with the wearing parts (mill body, stirring arms, and media) made from silicon nitride. Commercial silicon and Si3N4 powders were milled to fine uniform particles with only minimal contamination - primarily from wear of the sintered Si3N4 media.
Byrgazov, Konstantin; Lucini, Chantal Blanche; Berkowitsch, Bettina; Koenig, Margit; Haas, Oskar A; Hoermann, Gregor; Valent, Peter; Lion, Thomas
2016-11-22
Point mutations in the ABL1 kinase domain are an important mechanism of resistance to tyrosine kinase inhibitors (TKI) in BCR-ABL1-positive and, as recently shown, BCR-ABL1-like leukemias. The cell line Ba/F3 lentivirally transduced with mutant BCR-ABL1 constructs is widely used for in vitro sensitivity testing and response prediction to tyrosine kinase inhibitors. The transposon-based Sleeping Beauty system presented offers several advantages over lentiviral transduction including the absence of biosafety issues, faster generation of transgenic cell lines, and greater efficacy in introducing large gene constructs. Nevertheless, both methods can mediate multiple insertions in the genome. Here we show that multiple BCR-ABL1 insertions result in elevated IC50 levels for individual TKIs, thus overestimating the actual resistance of mutant subclones. We have therefore established flow-sorting-based fractionation of BCR-ABL1-transformed Ba/F3 cells facilitating efficient enrichment of cells carrying single-site insertions, as demonstrated by FISH-analysis. Fractions of unselected Ba/F3 cells not only showed a greater number of BCR-ABL1 hybridization signals, but also revealed higher IC50 values for the TKIs tested. The data presented highlight the need to carefully select transfected cells by flow-sorting, and to control the insertion numbers by FISH and real-time PCR to permit unbiased in vitro testing of drug resistance.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-10
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 13526-001] Bowersock Mills...: Bowersock Mills Power Company (Bowersock). e. Name of Project: Bowersock Mills and Power Company Expanded....S.C. 791(a)-825(r). h. Applicant Contact: Sarah Hill-Nelson, The Bowersock Mills and Power Company...
Children's Rights, "die Antipadagogen," and the Paternalism of John Stuart Mill.
ERIC Educational Resources Information Center
Nordenbo, Sven Erik
1987-01-01
Mill's liberty principle and the children's rights movement ("die Antipadagogen") are discussed in terms of Mill's attitude of paternalism in children's education. Mill contends that the individual liberty of children must be limited for their own good. Proponents of educational liberalism are not justified in claiming Mill as a…
NASA Astrophysics Data System (ADS)
Baricz, Árpád
2008-04-01
In this paper we study the monotonicity properties of some functions involving the Mills' ratio of the standard normal law. From these we deduce some new functional inequalities involving the Mills' ratio, and we show that the Mills' ratio is strictly completely monotonic. At the end of this paper we present some Turán-type inequalities for Mills' ratio.
NASA Astrophysics Data System (ADS)
Hou, Shang-Chieh; Su, Yuh-Fan; Chang, Chia-Chin; Hu, Chih-Wei; Chen, Tsan-Yao; Yang, Shun-Min; Huang, Jow-Lay
2017-05-01
The submicro-sized and nanostructured Si aggregated powder is prepared by combinational routes of high energy mechanical milling (HEMM) and wet milling. Milled Si powder is investigated by particle size analyzer, SEM, TEM, XPS and XRD as well as the control ones. Its electrode is also investigated by in situ XRD and electrochemical performance. Morphology reveals that combining the high energy mechanical milling and wet milling not only fracture primary Si particles but also form submicro-sized Si aggregates constructed by amorphous and nanocrystalline phases. Moreover, XPS shows that wet milling in ethanol trigger Sisbnd Osbnd CH2CH3 bonding on Si surface might enhance the SEI formation. In situ XRD analysis shows negative electrode made of submicro-sized Si aggregated powder can effectively suppress formation of crystalline Li15Si4 during lithiation and delithiation due to amorphous and nanocrystalline construction. Thus, the submicro-sized Si powder with synergistic effects combining the high energy mechanical milling and wet milling in ethanol as negative electrode performs better capacity retention.
BSM Delta Qualification 2, volume 3, book 2
NASA Technical Reports Server (NTRS)
1994-01-01
This report, presented in three volumes, provides the results of a two-motor Delta Qualification 2 program conducted in 1993 to certify the following enhancements for incorporation into booster separation motor (BSM0 flight hardware: vulcanized-in-place nozzle aft closure insulation; new iso-static ATJ bulk graphite throat insert material, adhesive EA9394 for bonding the nozzle throat, igniter grain rod/centering insert/igniter case; deletion of the igniter adapter insulator ring; deletion of the igniter adapter/igniter case interface RTV; and deletion of loctite from igniter retainer plate threads. The enhancements above directly resulted from (1) the BSM total quality management (TQM) team initiatives to enhance the BSM producibility, and (2) the necessity to qualify new throat insert and adhesive systems to replace existing materials that will not be available. Testing was completed at both the component and motor levels. Component testing was accomplished to screen candidate materials (e.g., throat materials, adhesive systems) and to optimize processes (e.g., aft closure insulator vulcanization approach) prior to their incorporation into the test motors. Motor testing--consisting of two motors, randomly selected by USBI's on-site quality personnel from production lot AAY, which were modified to accept the enhancements -- was completed to provide the final qualification of the enhancements for incorporation into flight hardware. Volume 3, Book 2 provides various supporting documentation to the previous volumes with regards to the testing of the two Delta qualification units: data acceptance records, thermal conditioning analysis, igniter adapter thermal flake analysis, laboratory adhesive (EA-9394) qualification report, throat insert thermal/structural analysis, Delta Qualification Nonconformance Reports (NCR's), O-ring seating tests, and interim test report for vulcanization process qualification.
The Direct Insertion of the ACL Carries More Load than the Indirect Insertion
Nawabi, Danyal H.; Tucker, Scott; Jones, Kristofer J.; Nguyen, Joseph; Wickiewicz, Thomas L.; Imhauser, Carl; Pearle, Andrew
2014-01-01
Objectives: Recent histological studies have shown that the ACL consists of two different structures: the direct and indirect insertions. The direct insertion is located along the lateral intercondylar ridge and the indirect insertion is ‘lower’ in the notch, adjacent to the posterior articular cartilage. The ‘lower’ position has become more popular for locating the femoral tunnel, as surgeons switch to the anteromedial (AM) portal drilling technique in order to place the graft in the region of the native footprint. However, a recent registry-based outcomes study has reported a 1.5 times higher graft failure rate for AM portal versus traditional transtibial techniques. The objective of this study was to investigate the load characteristics of the native ACL in the regions of the direct and indirect insertions. We hypothesized that the direct insertion would carry more load than the indirect insertion. Methods: Twelve cadaveric knees were mounted to a six degree of freedom robot equipped with a universal force-moment sensor. We simulated the Lachman and anterior drawer tests at 30oand 90o of flexion by applying a 134N anterior load, and the pivot shift test at 15o flexion by applying combined valgus (8Nm) and internal (4Nm) rotational moments. The kinematic pathway required to achieve these loading conditions was recorded for each intact knee. Using position control to repeat the loading paths, the robot recorded the loads for the ACL intact, ACL partially sectioned, and ACL completely sectioned states. Sectioning Protocol: The lateral intercondylar ridge and posterior articular margin was identified in each case. The 50% mark between this two areas was used to delineate the regions of the direct and indirect insertions (Fig. 1). Sectioning order was alternated between each cadaver. Footprint Digitization: The borders of the sectioned areas were digitized post-sectioning and mapped onto a computed tomography (CT) scan of each knee. The sectioning method was assessed under a blinded validation by experienced observers (TW, AP) who excluded two specimens that did not conform to the objective definitions of the sectioning method. Statistics: Loads were compared between direct and indirect locations at different flexion angles by conducting two-way repeated measures ANOVA models. Results: Under an anterior tibial load at 30o flexion, the direct insertion carried 83.9% (±7.2%) of the total ACL load compared to 16.1% (±7.2%) in the indirect insertion (p<0.001). The direct insertion also carried more load at 90o flexion (95.2% vs 4.8%; p<0.001). Under a combined rotatory load at 15o flexion, the direct insertion carried 84.2% (±4.2%)of the total ACL load compared to 15.8% (±4.2%) in the indirect insertion (p<0.001). Conclusion: The fibres in the direct insertion of the ACL carry more load than fibres in the indirect insertion. Previous studies have suggested that the direct insertion plays a major role in the mechanical link between the ACL and bone. With the current shift in emphasis towards anatomic ACL reconstruction, it may be beneficial to create the femoral tunnel within the direct insertion rather than ‘lower’ in the notch. Although further work is required in determining graft behaviour at the new insertions sites described in this study, our findings suggest that placing a graft in the region of the direct insertion may be an important consideration when adhering to the principles of anatomic ACL reconstruction.
Discrete element method based scale-up model for material synthesis using ball milling
NASA Astrophysics Data System (ADS)
Santhanam, Priya Radhi
Mechanical milling is a widely used technique for powder processing in various areas. In this work, a scale-up model for describing this ball milling process is developed. The thesis is a combination of experimental and modeling efforts. Initially, Discrete Element Model (DEM) is used to describe energy transfer from milling tools to the milled powder for shaker, planetary, and attritor mills. The rolling and static friction coefficients are determined experimentally. Computations predict a quasisteady rate of energy dissipation, E d, for each experimental configuration. It is proposed that the milling dose defined as a product of Ed and milling time, t, divided by the mass of milled powder, mp characterizes the milling progress independently of the milling device or milling conditions used. Once the milling dose is determined for one experimental configuration, it can be used to predict the milling time required to prepare the same material in any milling configuration, for which Ed is calculated. The concept is validated experimentally for DEM describing planetary and shaker mills. For attritor, the predicted Ed includes substantial contribution from milling tool interaction events with abnormally high forces (>103 N). The energy in such events is likely dissipated to heat or plastically deform milling tools rather than refine material. Indeed, DEM predictions for the attritor correlate with experiments when such events are ignored in the analysis. With an objective of obtaining real-time indicators of milling progress, power, torque, and rotation speed of the impeller of an attritor mill are measured during preparation of metal matrix composite powders in the subsequent portion of this thesis. Two material systems are selected and comparisons made between in-situ parameters and experimental milling progress indicators. It is established that real-time measurements can certainly be used to describe milling progress. However, they need to be interpreted carefully depending on hardness of brittle component relative to milling media. To improve the DEM model of the attritor mill, it is desired to avoid the removal of unrealistic, high-force events using an approach that would not predict such events in the first place. It is observed that during experiments in attritor, balls may jam causing an increased resistance to the impeller's rotation. The impeller may instantaneously slow down, quickly returning to its pre-set rotation rate. Previous DEM models did not account for such rapid changes in the impeller's rotation. In this work, this relationship between impeller's torque and rotation rate is obtained experimentally and introduced in DEM. As a result, predicted Ed, are shown to correlate well with the experimental data. Finally, a methodology is proposed combining an experiment and its DEM description enabling one to identify the appropriate interaction parameters for powder systems. The experiment uses a miniature vibrating hopper and can be applied to characterize the powder flow for variety of materials. The hopper is designed to hold up to 20,000 particles of 50-mum diameter, which can be directly described in DEM. Based on comparison of discharge rate from experiments and model, all 6 interaction parameters were analyzed and the ideal conditions identified for Zirconia beads. The values of these parameters for powders are generally not the same as those established for macroscopic bodies. In addition, effects of some other experimental parameters such as particle size distribution and amplitude of vibration are also investigated.
System and method of forming nanostructured ferritic alloy
Dial, Laura Cerully; DiDomizio, Richard; Alinger, Matthew Joseph; Huang, Shenyan
2016-07-26
A system for mechanical milling and a method of mechanical milling are disclosed. The system includes a container, a feedstock, and milling media. The container encloses a processing volume. The feedstock and the milling media are disposed in the processing volume of the container. The feedstock includes metal or alloy powder and a ceramic compound. The feedstock is mechanically milled in the processing volume using metallic milling media that includes a surface portion that has a carbon content less than about 0.4 weight percent.
Latif, Rana K; Bautista, Alexander F; Memon, Saima B; Smith, Elizabeth A; Wang, Chenxi; Wadhwa, Anupama; Carter, Mary B; Akca, Ozan
2012-03-01
Our goal was to determine whether simulation combined with didactic training improves sterile technique during ultrasound (US)-guided central venous catheter (CVC) insertion compared with didactic training alone among novices. We hypothesized that novices who receive combined didactic and simulation-based training would perform similarly to experienced residents in aseptic technique, knowledge, and perception of comfort during US-guided CVC insertion on a simulator. Seventy-two subjects were enrolled in a randomized, controlled trial of an educational intervention. Fifty-four novices were randomized into either the didactic group or the simulation combined with didactic group. Both groups received didactic training but the simulation combined with didactic group also received simulation-based CVC insertion training. Both groups were tested by demonstrating US-guided CVC insertion on a simulator. Aseptic technique was scored on 8 steps as "yes/no" and also using a 7-point Likert scale with 7 being "excellent technique" by a rater blinded to subject randomization. After initial testing, the didactic group was offered simulation-based training and retesting. Both groups also took a pre- and posttraining test of knowledge and rated their comfort with US and CVC insertion pre- and posttraining on a 5-point Likert scale. Subsequently, 18 experienced residents also took the test of knowledge, rated their comfort level, and were scored while performing aseptic US-guided CVC insertion using a simulator. The simulation combined with didactic group achieved a 167% (95% confidence interval [CI] 133%-167%) incremental increase in yes/no scores and 115% (CI 112%-127%) incremental increase in Likert scale ratings on aseptic technique compared with novices in the didactic group. Compared with experienced residents, simulation combined with didactic trained novices achieved an increase in aseptic scores with a 33.3% (CI 16.7%-50%) increase in yes/no ratings and a 20% (CI 13.3%-40%) increase in Likert scaled ratings, and scored 2.5-fold higher on the test of knowledge. There was a 3-fold increase in knowledge and 2-fold increase in comfort level among all novices (P < 0.001) after combined didactic and simulation-based training. Simulation combined with didactic training is superior to didactic training alone for acquisition of clinical skills such as US-guided CVC insertion. After combined didactic and simulation-based training, novices can outperform experienced residents in aseptic technique as well as in measurements of knowledge.
NASA Astrophysics Data System (ADS)
Wang, Bo; Wei, Shicheng; Wang, Yujiang; Liang, Yi; Guo, Lei; Xue, Junfeng; Pan, Fusheng; Tang, Aitao; Chen, Xianhua; Xu, Binshi
2018-03-01
Nano-titanium (Nano-Ti) was prepared by high-energy ball milling from pure Ti power and grinding agents (Epoxy resin) at room temperature. The effect of milling time on structure and properties of Nano-Ti polymer were investigated systematically. The results show that high-energy ball milling is an effective way to produce Nano-Ti polymer. The dispersion stability and compatibility between Ti power and grinding agents are improved by prolonging the milling time at a certain degree, that is to say, the optimization milling time is 240 min. The particle size of Ti powder and the diffraction peaks intensity of Ti decrease obviously as the milling time increases due to the compression stress, shear friction and other mechanical forces are formed during ball milling. FT-IR result displays that the wavenumber of all the bands move to lower wavenumber after ball milling, and the epoxy ring is open. The system internal energy rises owing to the broken epoxy group and much more Nano-Ti is formed to promote the grafting reaction between Nano-Ti and epoxy resin. The results from TEM and XPS also prove that. And the grafting ration is maximum as the milling time is 240 min, the mass loss ratio is 17.53%.
Sakwanichol, Jarunee; Puttipipatkhachorn, Satit; Ingenerf, Gernot; Kleinebudde, Peter
2012-01-01
Different experimental factorial designs were employed to evaluate granule properties obtained from oscillating granulator and roll mill. Four oscillating-granulator parameters were varied, i.e. rotor speed, oscillating angle, aperture of mesh screen and rotor type. Six roll-mill parameters that were throughput, speed ratio in both first and second stages, gap between roll pair in both stages and roll-surface texture were also investigated. Afterwards, the granule properties obtained from two milling types with similar median particle size were compared. All milling parameters in both milling types affected significantly the median particle size, size distribution and amount of fine particles (P < 0.05), except the rotor types of oscillating granulator on fines. Only three milling parameters influenced significantly the flowability (P < 0.05). These were the throughput and the gap size in the first stage of roll mill and the sieve size of oscillating granulator. In comparison between milling types, the differences of granule properties were not practically relevant. However, the roll mill had much higher capacity than the oscillating granulator about seven times, resulting in improving energy savings per unit of product. Consequently, the roll mill can be applied instead of oscillating granulator for roll compaction/dry granulation technique.
NASA Astrophysics Data System (ADS)
Liu, Zhijie; Wang, Wenchun; Yang, Dezheng; Wang, Sen; Dai, Leyang
2016-07-01
Nano-size aluminum nitride (AlN) powders have been successfully synthesized with a high efficiency method through annealing from milling assisted by discharge plasma (p-milling) alumina (Al2O3) precursors. The characterization of the p-milling Al2O3 powders and the synthesized AlN are investigated. Compared to conventional ball milling (c-milling), it can be found that the precursors by p-milling have a finer grain size with a higher specific surface area, which lead to a faster reaction efficiency and higher conversion to AlN at lower temperatures. The activation energy of p-milling Al2O3 is found to be 371.5 kJ/mol, a value that is much less than the reported value of the unmilled and the conventional milled Al2O3. Meanwhile, the synthesized AlN powders have unique features, such as an irregular lamp-like morphology with uniform particle distribution and fine average particle size. The results are attributed to the unique synergistic effect of p-milling, which is the effect of deformation, fracture, and cold welding of Al2O3 powders resulting from ball milling, that will be enhanced due to the introduction of discharge plasma. supported by National Natural Science Foundation of China (No. 51177008)
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
Accompanying a multimedia resource unit on aspects of rice growing, volume eight of the geography collection includes a section introducing terminology, a viewing guide to the filmstrips and unit test items. Rice farming and marketing in Australia and growing methods in several countries are presented with regional studies in southeast Australia.…
40 CFR 63.1347 - Standards for raw and finish mills.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Standards for raw and finish mills. 63... and Operating Limits § 63.1347 Standards for raw and finish mills. The owner or operator of each new or existing raw mill or finish mill at a facility which is a major source subject to the provisions...
Validation of the ROMI-RIP rough mill simulator
Edward R. Thomas; Urs Buehlmann
2002-01-01
The USDA Forest Service's ROMI-RIP rough mill rip-first simulation program is a popular tool for analyzing rough mill conditions, determining more efficient rough mill practices, and finding optimal lumber board cut-up patterns. However, until now, the results generated by ROMI-RIP have not been rigorously compared to those of an actual rough mill. Validating the...
10. TROJAN MILL, EXTERIOR FROM EAST, c. 191928. ADDITION TO ...
10. TROJAN MILL, EXTERIOR FROM EAST, c. 1919-28. ADDITION TO THE EAST END OF MILLING FLOOR VISIBLE WITH TRAM ENTRY DOOR. ALSO SEEN ARE THE ADDITIONS FOR MILL SOLUTION TANKS AND THE EAST SIDE OF SAMPLING ROOMS. CREDIT JW. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD
2015-03-09
THE ORION HEAT SHIELD THAT SUCCESSFULLY SURVIVED A HIGH-VELOCITY REENTRY DURING ITS DEC. 5 FLIGHT TEST, IS CONTINUING ITS JOURNEY, NOW AT MARSHALL. IT ARRIVED ON MONDAY, MARCH 9 AND WILL BE INSTALLED IN THE BUILDING 4705 7-AXIS MILLING AND MACHINING CENTER.
15. STONE BURR MILL PROBABLY USED FOR GRINDING FEED. ONLY ...
15. STONE BURR MILL PROBABLY USED FOR GRINDING FEED. ONLY REMAINING MILL MACHINERY William E. Barrett, photographer, 1973 - Thomas Shepherd's Grist Mill, High Street Vicinity, Shepherdstown, Jefferson County, WV
A High-Throughput Arabidopsis Reverse Genetics System
Sessions, Allen; Burke, Ellen; Presting, Gernot; Aux, George; McElver, John; Patton, David; Dietrich, Bob; Ho, Patrick; Bacwaden, Johana; Ko, Cynthia; Clarke, Joseph D.; Cotton, David; Bullis, David; Snell, Jennifer; Miguel, Trini; Hutchison, Don; Kimmerly, Bill; Mitzel, Theresa; Katagiri, Fumiaki; Glazebrook, Jane; Law, Marc; Goff, Stephen A.
2002-01-01
A collection of Arabidopsis lines with T-DNA insertions in known sites was generated to increase the efficiency of functional genomics. A high-throughput modified thermal asymetric interlaced (TAIL)-PCR protocol was developed and used to amplify DNA fragments flanking the T-DNA left borders from ∼100,000 transformed lines. A total of 85,108 TAIL-PCR products from 52,964 T-DNA lines were sequenced and compared with the Arabidopsis genome to determine the positions of T-DNAs in each line. Predicted T-DNA insertion sites, when mapped, showed a bias against predicted coding sequences. Predicted insertion mutations in genes of interest can be identified using Arabidopsis Gene Index name searches or by BLAST (Basic Local Alignment Search Tool) search. Insertions can be confirmed by simple PCR assays on individual lines. Predicted insertions were confirmed in 257 of 340 lines tested (76%). This resource has been named SAIL (Syngenta Arabidopsis Insertion Library) and is available to the scientific community at www.tmri.org. PMID:12468722
Effect of placement angle on the stability of loaded titanium microscrews in beagle jaws.
Xu, Zhenrui; Wu, Yeke; Zhao, Lixing; Zhou, Yuqiao; Wei, Xing; Tang, Na; Feng, Xiaoxia; Tang, Tian; Zhao, Zhihe
2013-07-01
To evaluate the effect of insertion angle on stability of loaded titanium microscrews in beagle jaws. Forty-eight microscrews were inserted at four different angles (30°, 50°, 70°, and 90°) into the intraradicular zones of the mandibular first molars and third premolars of 12 beagles and immediately loaded with a force of 2 N for 8 weeks. Microcomputed tomography (micro-CT) and biomechanical pull-out tests were used to assess osseointegration of the interface. All micro-CT parameters and maximum pull-out force (FMAX) of the microscrews were affected by insertion angles of microscrews. Higher micro-CT parameters and FMAX were seen for implants inserted at angles between 50° and 70° (P < .05). Excessive oblique and vertical insertion angles resulted in reduced stability (P < .05). An insertion angle of 50° to 70° is more favorable than excessive oblique or vertical angles to achieve stability of microscrews.
Additive Manufacturing for Highly Efficient Window Inserts CRADA Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roschli, Alex C.; Chesser, Phillip C.; Love, Lonnie J.
ORNL partnered with the Mackinac Technology Company to demonstrate how additive manufacturing can be used to create highly energy efficient window inserts for retrofit in pre-existing buildings. Many early iterations of the window inserts were fabricated using carbon fiber reinforced thermoplastics and polycarbonate films as a stand in for the low-e coated films produced by the Mackinac Technology Company. After demonstration of the proof of concept, i.e. custom window inserts with tensioned film, the materials used for the manufacture of the frames was more closely examined. Hollow particle-filled syntactic foam and low-density polymer composites formed by expandable microspheres were exploredmore » as the materials used to additively manufacture the frames of the inserts. It was concluded that low-cost retrofit window inserts in custom sizes could be easily fabricated using large scale additive manufacturing. Furthermore, the syntactic and expanded foams developed and tested satisfy the mechanical performance requirements for the application.« less
van der Klift, Heleen M; Tops, Carli M; Hes, Frederik J; Devilee, Peter; Wijnen, Juul T
2012-07-01
Heterozygous germline mutations in the mismatch repair gene PMS2 predispose carriers for Lynch syndrome, an autosomal dominant predisposition to cancer. Here, we present a LINE-1-mediated retrotranspositional insertion in PMS2 as a novel mutation type for Lynch syndrome. This insertion, detected with Southern blot analysis in the genomic DNA of the patient, is characterized as a 2.2 kb long 5' truncated SVA_F element. The insertion is not detectable by current diagnostic testing limited to MLPA and direct Sanger sequencing on genomic DNA. The molecular nature of this insertion could only be resolved in RNA from cultured lymphocytes in which nonsense-mediated RNA decay was inhibited. Our report illustrates the technical problems encountered in the detection of this mutation type. Especially large heterozygous insertions will remain unnoticed because of preferential amplification of the smaller wild-type allele in genomic DNA, and are probably underreported in the mutation spectra of autosomal dominant disorders. © 2012 Wiley Periodicals, Inc.
The effect of various pozzolanic additives on the concrete strength index
NASA Astrophysics Data System (ADS)
Vitola, L.; Sahmenko, G.; Erdmane, D.; Bumanis, G.; Bajare, D.
2017-10-01
The concrete industry is searching continuously for new effective mineral additives to improve the concrete properties. Replacing cement with the pozzolanic additives in most cases has resulted not only in positive impact on the environment but also has improved strength and durability of the concrete. Effective pozzolanic additives can be obtained from natural resources such as volcanic ashes, kaolin and other sediments as well as from different production industries that create various by-products with high pozzolanic reactivity. Current research deals with effectiveness evaluation of various mineral additives/wastes, such as coal combustion bottom ash, barley bottom ash, waste glass and metakaolin containing waste as well as calcined illite clays as supplementary cementitious materials, to be used in concrete production as partial cement replacement. Most of the examined materials are used as waste stream materials with potential reactive effect on the concrete. Milling time and fineness of the tested supplementary material has been evaluated and effectiveness was detected. Results indicate that fineness of the tested materials has crucial effect on the concrete compressive strength index. Not in all cases the prolonged milling time can increase fineness and reactivity of the supplementary materials; however the optimal milling time and fineness of the pozolanic additives increased the strength index of concrete up to 1.16 comparing to reference, even in cases when cement was substituted by 20 w%.
Chen, Ming-Jun; Cheng, Jian; Yuan, Xiao-Dong; Liao, Wei; Wang, Hai-Jun; Wang, Jing-He; Xiao, Yong; Li, Ming-Quan
2015-01-01
Repairing initial slight damage site into stable structures by engineering techniques is the leading strategy to mitigate the damage growth on large-size components used in laser-driven fusion facilities. For KH2PO4 crystals, serving as frequency converter and optoelectronic switch-Pockels cell, micro-milling has been proven the most promising method to fabricate these stable structures. However, tool marks inside repairing pit would be unavoidably introduced due to the wearing of milling cutter in actual repairing process. Here we quantitatively investigate the effect of tool marks on repairing quality of damaged crystal components by simulating its induced light intensification and testing the laser-induced damage threshold. We found that due to the formation of focusing hot spots and interference ripples, the light intensity is strongly enhanced with the presence of tool marks, especially for those on rear surfaces. Besides, the negative effect of tool marks is mark density dependent and multiple tool marks would aggravate the light intensification. Laser damage tests verified the role of tool marks as weak points, reducing the repairing quality. This work offers new criterion to comprehensively evaluate the quality of repaired optical surfaces to alleviate the bottleneck issue of low laser damage threshold for optical components in laser-driven fusion facilities. PMID:26399624
41. PHOTOCOPY OF HISTORIC SURVEY OF INDIANA COTTON MILLS, CANNELTON, ...
41. PHOTOCOPY OF HISTORIC SURVEY OF INDIANA COTTON MILLS, CANNELTON, INDIANA, SHOWING LOCATION OF ALL STRUCTURES IN THE CANNELTON MILL COMPLEX - Cannelton Cotton Mill, Front & Fourth Streets, Cannelton, Perry County, IN
INTERIOR OF SECOND FLOOR BRIDGE BETWEEN PLANING MILL AND CAR ...
INTERIOR OF SECOND FLOOR BRIDGE BETWEEN PLANING MILL AND CAR MACHINE SHOP, LOOKING SOUTH TOWARD PLANING MILL. - Southern Pacific, Sacramento Shops, Planing Mill, 111 I Street, Sacramento, Sacramento County, CA
Powder properties of hydrogenated ball-milled graphite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Y., E-mail: y.zhang062012@gmail.com; Wedderburn, J.; Harris, R.
2014-12-15
Ball milling is an effective way of producing defective and nanostructured graphite. In this work, the hydrogen storage properties of graphite, ball-milled in a tungsten carbide milling pot under 3 bar hydrogen for various times (0–40 h), were investigated by TGA-Mass Spectrometry, XRD, SEM and laser diffraction particle size analysis. For the conditions used in this study, 10 h is the optimum milling time resulting in desorption of 5.5 wt% hydrogen upon heating under argon to 990 °C. After milling for 40 h, the graphite became significantly more disordered, and the amount of desorbed hydrogen decreased. After milling up tomore » 10 h, the BET surface area increased while particle size decreased; however, there is no apparent correlation between these parameters, and the hydrogen storage properties of the hydrogenated ball-milled graphite.« less
Effect of milling atmosphere on structural and magnetic properties of Ni-Zn ferrite nanocrystalline
NASA Astrophysics Data System (ADS)
Hajalilou, Abdollah; Hashim, Mansor; Ebrahimi-Kahrizsangi, Reza; Masoudi Mohamad, Taghi
2015-04-01
Powder mixtures of Zn, NiO, and Fe2O3 are mechanically alloyed by high energy ball milling to produce Ni-Zn ferrite with a nominal composition of Ni0.36Zn0.64Fe2O4. The effects of milling atmospheres (argon, air, and oxygen), milling time (from 0 to 30 h) and heat treatment are studied. The products are characterized using x-ray diffractometry, field emission scanning electron microscopy equipped with energy-dispersive x-ray spectroscopy, and transmitted electron microscopy. The results indicate that the desired ferrite is not produced during the milling in the samples milled under either air or oxygen atmospheres. In those samples milled under argon, however, Zn/NiO/Fe2O3 reacts with a solid-state diffusion mode to produce Ni-Zn ferrite nanocrystalline in a size of 8 nm after 30-h-milling. The average crystallite sizes decrease to 9 nm and 10 nm in 30-h-milling samples under air and oxygen atmospheres, respectively. Annealing the 30-h-milling samples at 600 °C for 2 h leads to the formation of a single phase of Ni-Zn ferrite, an increase of crystallite size, and a reduction of internal lattice strain. Finally, the effects of the milling atmosphere and heating temperature on the magnetic properties of the 30-h-milling samples are investigated. Project supported by the University Putra Malaysia Graduate Research Fellowship Section.
Patulin surveillance in apple cider and juice marketed in Michigan.
Harris, Kerri L; Bobe, Gerd; Bourquin, Leslie D
2009-06-01
Patulin is the most common mycotoxin found in apples and apple juices. The objective of this study was to determine the concentrations of patulin in (i) apple cider produced and marketed by Michigan apple cider mills during the fall seasons of 2002 to 2003 and 2003 to 2004 and (ii) apple juice and cider, including shelf-stable products, marketed in retail grocery stores in Michigan throughout 2005 and 2006. End product samples (n=493) obtained from 104 Michigan apple cider mills were analyzed for patulin concentration by using solid-phase extraction followed by high-performance liquid chromatography. Patulin was detected (> or =4 microg/liter) in 18.7% of all cider mill samples, with 11 samples (2.2%) having patulin concentrations of > or =50 microg/liter. A greater percentage of cider samples obtained from mills using thermal pasteurization contained detectable patulin (28.4%) than did those from mills using UV light radiation (13.5%) or no pathogen reduction treatment (17.0%). Among retail grocery store samples (n=159), 23% of apple juice and cider samples contained detectable patulin, with 18 samples (11.3%) having patulin concentrations of > or =50 microg/liter. The U.S. Food and Drug Administration (FDA) action level for patulin is 50 microg/kg. Some apple juice samples obtained from retail grocery stores had exceptionally high patulin concentrations, ranging up to 2700 microg/liter. Collectively, these results indicate that most apple cider and juice test samples from Michigan were below the FDA action level for patulin but that certain apple cider and juice processors have inadequate controls over patulin concentrations in final products. The industry, overall, should focus on improved quality of fruit used in juice production and improve culling procedures to reduce patulin concentrations.
Haile-Selassie, Yohannes
2010-01-01
The earliest evidence of Australopithecus goes back to ca 4.2 Ma with the first recorded appearance of Australopithecus ‘anamensis’ at Kanapoi, Kenya. Australopithecus afarensis is well documented between 3.6 and 3.0 Ma mainly from deposits at Laetoli (Tanzania) and Hadar (Ethiopia). The phylogenetic relationship of these two ‘species’ is hypothesized as ancestor–descendant. However, the lack of fossil evidence from the time between 3.6 and 3.9 Ma has been one of its weakest points. Recent fieldwork in the Woranso-Mille study area in the Afar region of Ethiopia has yielded fossil hominids dated between 3.6 and 3.8 Ma. These new fossils play a significant role in testing the proposed relationship between Au. anamensis and Au. afarensis. The Woranso-Mille hominids (3.6–3.8 Ma) show a mosaic of primitive, predominantly Au. anamensis-like, and some derived (Au. afarensis-like) dentognathic features. Furthermore, they show that, as currently known, there are no discrete and functionally significant anatomical differences between Au. anamensis and Au. afarensis. Based on the currently available evidence, it appears that there is no compelling evidence to falsify the hypothesis of ‘chronospecies pair’ or ancestor–descendant relationship between Au. anamensis and Au. afarensis. Most importantly, however, the temporally and morphologically intermediate Woranso-Mille hominids indicate that the species names Au. afarensis and Au. anamensis do not refer to two real species, but rather to earlier and later representatives of a single phyletically evolving lineage. However, if retaining these two names is necessary for communication purposes, the Woranso-Mille hominids are best referred to as Au. anamensis based on new dentognathic evidence. PMID:20855306
Refining the site conceptual model at a former uranium mill site in Riverton, Wyoming, USA
Dam, William; Campbell, Sam; Johnson, Ray; ...
2015-07-07
Milling activities at a former uranium mill site near Riverton, Wyoming, USA, contaminated the shallow groundwater beneath and downgradient of the site. Although the mill operated for <6 years (1958-1963), its impact remains an environmental liability. Groundwater modeling predicted that contaminant concentrations were declining steadily, which confirmed the conceptual site model (CSM). However, local flooding in 2010 mobilized contaminants that migrated downgradient from the Riverton site and resulted in a dramatic increase in groundwater contaminant concentrations. This observation indicated that the original CSM was inadequate to explain site conditions and needed to be refined. In response to the new observationsmore » after the flood, a collaborative investigation to better understand site conditions and processes commenced. This investigation included installing 103 boreholes to collect soil and groundwater samples, sampling and analysis of evaporite minerals along the bank of the Little Wind River, an analysis of evaportranspiration in the shallow aquifer, and sampling naturally organic-rich sediments near groundwater discharge areas. The enhanced characterization revealed that the existing CSM did not account for high uranium concentrations in groundwater remaining on the former mill site and groundwater plume stagnation near the Little Wind River. Observations from the flood and subsequent investigations indicate that additional characterization is still needed to continue refining the CSM and determine the viability of the natural flushing compliance strategy. Additional sampling, analysis, and testing of soil and groundwater are necessary to investigate secondary contaminant sources, mobilization of contaminants during floods, geochemical processes, contaminant plume stagnation, distribution of evaporite minerals and organic-rich sediments, and mechanisms and rates of contaminant transfer from soil to groundwater. Future data collection will be used to continually revise the CSM and evaluate the compliance strategy at the site.« less
Afify, Ahmed; Haney, Stephan; Verrett, Ronald; Mansueto, Michael; Cray, James; Johnson, Russell
2018-02-01
Studies evaluating the marginal adaptation of available computer-aided design and computer-aided manufacturing (CAD-CAM) noble alloys for metal-ceramic prostheses are lacking. The purpose of this in vitro study was to evaluate the vertical marginal adaptation of cast, milled, and direct metal laser sintered (DMLS) noble metal-ceramic 3-unit fixed partial denture (FDP) frameworks before and after fit adjustments. Two typodont teeth were prepared for metal-ceramic FDP abutments. An acrylic resin pattern of the prepared teeth was fabricated and cast in nickel-chromium (Ni-Cr) alloy. Each specimen group (cast, milled, DMLS) was composed of 12 casts made from 12 impressions (n=12). A single design for the FDP substructure was created on a laboratory scanner and used for designing the specimens in the 3 groups. Each specimen was fitted to its corresponding cast by using up to 5 adjustment cycles, and marginal discrepancies were measured on the master Ni-Cr model before and after laboratory fit adjustments. The milled and DMLS groups had smaller marginal discrepancy measurements than those of the cast group (P<.001). Significant differences were found in the number of adjustments among the groups, with the milled group requiring the minimum number of adjustments, followed by the DMLS and cast groups (F=30.643, P<.001). Metal-ceramic noble alloy frameworks fabricated by using a CAD-CAM workflow had significantly smaller marginal discrepancies compared with those with a traditional cast workflow, with the milled group demonstrating the best marginal fit among the 3 test groups. Manual refining significantly enhanced the marginal fit of all groups. All 3 groups demonstrated marginal discrepancies within the range of clinical acceptability. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Goulet, Richard R; Thompson, Patsy A; Serben, Kerrie C; Eickhoff, Curtis V
2015-03-01
Treated effluent discharge from uranium (U) mines and mills elevates the concentrations of U, calcium (Ca), magnesium (Mg), and sulfate (SO4 (2-) ) above natural levels in receiving waters. Many investigations on the effect of hardness on U toxicity have been experiments on the combined effects of changes in hardness, pH, and alkalinity, which do not represent water chemistry downstream of U mines and mills. Therefore, more toxicity studies with water chemistry encountered downstream of U mines and mills are necessary to support predictive assessments of impacts of U discharge to the environment. Acute and chronic U toxicity laboratory bioassays were realized with 6 freshwater species in waters of low alkalinity, circumneutral pH, and a range of chemical hardness as found in field samples collected downstream of U mines and mills. In laboratory-tested waters, speciation calculations suggested that free uranyl ion concentrations remained constant despite increasing chemical hardness. When hardness increased while pH remained circumneutral and alkalinity low, U toxicity decreased only to Hyalella azteca and Pseudokirchneriella subcapitata. Also, Ca and Mg did not compete with U for the same uptake sites. The present study confirms that the majority of studies concluding that hardness affected U toxicity were in fact studies in which alkalinity and pH were the stronger influence. The results thus confirm that studies predicting impacts of U downstream of mines and mills should not consider chemical hardness. Environ Toxicol Chem 2015;34:562-574. © 2014 The Authors. Published by Wiley Periodicals, Inc. on behalf of SETAC. © 2014 The Authors. Published by Wiley Periodicals, Inc. on behalf of SETAC.
NASA Astrophysics Data System (ADS)
Wang, Wen; Li, Boyu; Zhai, Sicheng; Xu, Juan; Niu, Zuozhe; Xu, Jing; Wang, Yan
2018-02-01
In this paper, FeSiBAlNiCo x (x = 0.2, 0.8) high-entropy alloy (HEA) powders were fabricated by mechanical alloying process, and the powders milled for 140 h were sintered by spark plasma sintering (SPS) technique. The microstructures and properties of as-milled powders and as-sintered samples were investigated. The results reveal that the final milling products (140 h) of both sample powders present the fully amorphous structure. The increased Co contents obviously enhance the glass forming ability and thermal stability of amorphous HEA powders, which are reflected by the shorter formation time of fully amorphous phase and the higher onset crystallization temperature, respectively. According to coercivity, the as-milled FeSiBAlNiCo x (x = 0.2, 0.8) powders (140 h) are the semi-hard magnetic materials. FeSiBAlNiCo0.8 HEA powders possess the highest saturation magnetization and largest remanence ratio. The SPS-ed products of both bulk HEAs are composed of body-centered cubic solid solution, and FeSi and FeB intermetallic phases. They possess the high relative density above 97% and excellent microhardness exceeding 1150 HV. The as-sintered bulks undergo the remarkable increase in saturation magnetization compared with the as-milled state. The SPS-ed FeSiBAlNiCo0.8 HEA exhibits the soft magnetic properties. The electrochemical corrosion test is carried out in 3.5% NaCl solution. The SPS-ed FeSiBAlNiCo0.2 HEA reveals the better passivity with low passive current density, and the higher pitting resistance with wide passive region.
Muhamad, Mohd Hafizuddin; Sheikh Abdullah, Siti Rozaimah; Abu Hasan, Hassimi; Abd Rahim, Reehan Adnee
2015-11-01
The complexity of residual toxic organics from biologically treated effluents of pulp and paper mills is a serious concern. To date, it has been difficult to choose the best treatment technique because each of the available options has advantages and drawbacks. In this study, two different treatment techniques using laboratory-scale aerobic sequencing batch reactors (SBRs) were tested with the same real recycled paper mill effluent to evaluate their treatment efficiencies. Two attached-growth SBRs using granular activated carbon (GAC) with and without additional biomass and a suspended-growth SBR were used in the treatment of real recycled paper mill effluent at a chemical oxygen demand (COD) level in the range of 800-1300 mg/L, a fixed hydraulic retention time of 24 h and a COD:N:P ratio of approximately 100:5:1. The efficiency of this biological treatment process was studied over a 300-day period. The six most important wastewater quality parameters, namely, chemical oxygen demand (COD), turbidity, ammonia (expressed as NH3-N), phosphorus (expressed as PO4(3)-P), colour, and suspended solids (SS), were measured to compare the different treatment techniques. It was determined that these processes were able to almost completely and simultaneously eliminate COD (99%) and turbidity (99%); the removals of NH3-N (90-100%), PO4(3)-P (66-78%), colour (63-91%), and SS (97-99%) were also sufficient. The overall performance results confirmed that an attached-growth SBR system using additional biomass on GAC is a promising configuration for wastewater treatment in terms of performance efficiency and process stability under fluctuations of organic load. Hence, this hybrid system is recommended for the treatment of pulp and paper mill effluents. Copyright © 2015 Elsevier Ltd. All rights reserved.