Science.gov

Sample records for insertable b-layer ibl

  1. The ATLAS Insertable B-Layer (IBL) project

    NASA Astrophysics Data System (ADS)

    Bilbao de Mendizabal, J.

    2013-12-01

    Preparing for the high luminosity LHC phase, the ATLAS experiment will upgrade its Pixel Detector with the installation of a new pixel layer. The new sub detector, called the Insertable B-Layer (IBL), will be installed during the LHC first shut down in 2013-2014, in between the innermost current pixel layer and the beampipe. To cope with the high radiation and pixel occupancy due to the proximity to the interaction point, a new readout chip FE-I4 and two different silicon sensor technologies, planar and 3D have been developed. Furthermore, the physics performance should be improved through the reduction of pixel size and a new mechanical support using lightweight staves. Two pre-series staves were made in order to qualify the assembly procedure, the loaded module electrical integrity and the readout chain before going into production.

  2. ``The Read-Out Driver'' ROD card for the Insertable B-layer (IBL) detector of the ATLAS experiment: commissioning and upgrade studies for the Pixel Layers 1 and 2

    NASA Astrophysics Data System (ADS)

    Balbi, G.; Bindi, M.; Chen, S. P.; Falchieri, D.; Flick, T.; Gabrielli, A.; Hauck, S.; Hsu, S. C.; Kretz, M.; Kugel, A.; Lama, L.; Morettini, P.; Travaglini, R.; Wensing, M.

    2014-01-01

    The upgrade of the ATLAS experiment at LHC foresees the insertion of an innermost silicon layer, called the Insertable B-layer (IBL). The IBL read-out system will be equipped with new electronics. The Readout-Driver card (ROD) is a VME board devoted to data processing, configuration and control. A pre-production batch has been delivered for testing with instrumented slices of the overall acquisition chain, aiming to finalize strategies for system commissioning. In this paper system setups and results will be described, as well as preliminary studies on changes needed to adopt the ROD for the ATLAS Pixel Layers 1 and 2.

  3. The ATLAS Insertable B-Layer: from construction to operation

    NASA Astrophysics Data System (ADS)

    La Rosa, A.

    2016-12-01

    The ATLAS Insertable B-Layer (IBL) is the innermost layer of pixel detectors, and was installed in May 2014 at a radius of 3.3 cm from the beam axis, between the existing Pixel detector and a new smaller radius beam-pipe. The new detector, built to cope with high radiation and occupancy, is the first large scale application of 3D sensors and CMOS 130 nm technology. The IBL detector construction was completed within about two years (2012 - 2014), and the key features and challenges met during the IBL project are presented, as well as its commissioning and operational experience at the LHC.

  4. Characterization of new hybrid pixel module concepts for the ATLAS Insertable B-Layer upgrade

    NASA Astrophysics Data System (ADS)

    Backhaus, M.

    2012-01-01

    The ATLAS Insertable B-Layer (IBL) collaboration plans to insert a fourth pixel layer inside the present Pixel Detector to recover from eventual failures in the current pixel system, especially the b-layer. Additionally the IBL will ensure excellent tracking, vertexing and b-tagging performance during the LHC phase I and add robustness in tracking with high luminosity pile-up. The expected peak luminosity for IBL is 2 to 3·1034 cm-2s-1 and IBL is designed for an integrated luminosity of 700 fb-1. This corresponds to an expected fluence of 5·1015 1 MeV neqcm-2 and a total ionizing dose of 250 MRad. In order to cope with these requirements, two new module concepts are under investigation, both based on a new front end IC, called FE-I4. This IC was designed as readout chip for future ATLAS Pixel Detectors and its first application will be the IBL. The planar pixel sensor (PPS) based module concept benefits from its well understood design, which is kept as similar as possible to the design of the current ATLAS Pixel Detector sensor. The second approach of the new three dimensional (3D) silicon sensor technology benefits from the shorter charge carrier drift distance to the electrodes, which completely penetrate the sensor bulk. Prototype modules of both sensor concepts have been build and tested in laboratory and test beam environment before and after irradiation. Both concepts show very high performance even after irradiation to 5·1015 1 MeV neqcm-2 and meet the IBL specifications in terms of hit efficiency being larger than 97%. Lowest operational threshold studies have been effected and prove independent of the used sensor concept the excellent performance of FE-I4 based module concepts in terms of noise hit occupancy at low thresholds.

  5. Characterization of the FE-I4B pixel readout chip production run for the ATLAS Insertable B-layer upgrade

    NASA Astrophysics Data System (ADS)

    Backhaus, M.

    2013-03-01

    The Insertable B-layer (IBL) is a fourth pixel layer that will be added inside the existing ATLAS pixel detector during the long LHC shutdown of 2013 and 2014. The new four layer pixel system will ensure excellent tracking, vertexing and b-tagging performance in the high luminosity pile-up conditions projected for the next LHC run. The peak luminosity is expected to reach 3·1034 cm-2s-1with an integrated luminosity over the IBL lifetime of 300 fb-1 corresponding to a design lifetime fluence of 5·1015 neqcm-2 and ionizing dose of 250 Mrad including safety factors. The production front-end electronics FE-I4B for the IBL has been fabricated at the end of 2011 and has been extensively characterized on diced ICs as well as at the wafer level. The production tests at the wafer level were performed during 2012. Selected results of the diced IC characterization are presented, including measurements of the on-chip voltage regulators. The IBL powering scheme, which was chosen based on these results, is described. Preliminary wafer to wafer distributions as well as yield calculations are given.

  6. ATLAS IBL Pixel Upgrade

    NASA Astrophysics Data System (ADS)

    La Rosa, A.; Atlas Ibl Collaboration

    2011-06-01

    The upgrade for ATLAS detector will undergo different phases towards super-LHC. The first upgrade for the Pixel detector will consist of the construction of a new pixel layer which will be installed during the first shutdown of the LHC machine (LHC phase-I upgrade). The new detector, called Insertable B-Layer (IBL), will be inserted between the existing pixel detector and a new (smaller radius) beam-pipe at a radius of 3.3 cm. The IBL will require the development of several new technologies to cope with increase of radiation or pixel occupancy and also to improve the physics performance which will be achieved by reducing the pixel size and of the material budget. Three different promising sensor technologies (planar-Si, 3D-Si and diamond) are currently under investigation for the pixel detector. An overview of the project with particular emphasis on the pixel module is presented in this paper.

  7. The ATLAS IBL BOC prototype

    NASA Astrophysics Data System (ADS)

    Schroer, N.

    2011-12-01

    The Pixel Detector of the ATLAS experiment at CERN will be upgraded with an Insertable B-Layer (IBL) in 2013. To handle the data readout the currently used VME card pairs consisting of a back of crate card (BOC) and a read out driver (ROD) are being redesigned. This paper presents details of the hardware design of the new BOC prototype, which takes advantage from modern FPGA technology and commercial optical modules and abandons the need for a variety of custom components used on the old card. Also the throughput is four times higher and additional features are implemented.

  8. Testing and firmware development for the ATLAS IBL BOC prototype

    NASA Astrophysics Data System (ADS)

    Wensing, M.

    2012-12-01

    For the coming upgrade pixel detector of the ATLAS experiment at the Large Hadron Collider a redesign of the current data readout is necessary. To communicate with the additional 448 front-end chips assembled in the Insertable B-Layer (IBL) new FPGA based readout cards consisting of a Back of Crate card (BOC) and a Read Out Driver (ROD) have been developed. This paper describes the firmware and hardware development of the new BOC prototype. Firmware tests, like electrical and optical loopback and communication tests with the new IBL front-end modules and the ROD will also be presented.

  9. Firmware development and testing of the ATLAS Pixel Detector / IBL ROD card

    NASA Astrophysics Data System (ADS)

    Gabrielli, A.; Backhaus, M.; Balbi, G.; Bindi, M.; Chen, S. P.; Falchieri, D.; Flick, T.; Hauck, S.; Hsu, S. C.; Kretz, M.; Kugel, A.; Lama, L.; Travaglini, R.; Wensing, M.

    2015-03-01

    The ATLAS Experiment is reworking and upgrading systems during the current LHC shut down. In particular, the Pixel detector has inserted an additional inner layer called the Insertable B-Layer (IBL). The Readout-Driver card (ROD), the Back-of-Crate card (BOC), and the S-Link together form the essential frontend data path of the IBL's off-detector DAQ system. The strategy for IBL ROD firmware development was three-fold: keeping as much of the Pixel ROD datapath firmware logic as possible, employing a complete new scheme of steering and calibration firmware, and designing the overall system to prepare for a future unified code version integrating IBL and Pixel layers. Essential features such as data formatting, frontend-specific error handling, and calibration are added to the ROD data path. An IBL DAQ test bench using a realistic front-end chip model was created to serve as an initial framework for full offline electronic system simulation. In this document, major firmware achievements concerning the IBL ROD data path implementation, test on the test bench and ROD prototypes, will be reported. Recent Pixel collaboration efforts focus on finalizing hardware and firmware tests for the IBL. The plan is to approach a complete IBL DAQ hardware-software installation by the end of 2014.

  10. The ATLAS IBL CO2 cooling system

    NASA Astrophysics Data System (ADS)

    Verlaat, B.; Ostrega, M.; Zwalinski, L.; Bortolin, C.; Vogt, S.; Godlewski, J.; Crespo-Lopez, O.; Van Overbeek, M.; Blaszcyk, T.

    2017-02-01

    The ATLAS Pixel detector has been equipped with an extra pixel layer in the space obtained by a smaller radius beam pipe. This new pixel layer called the Insertable B-Layer (IBL) was installed in 2014 and is operational in the current ATLAS data taking. The IBL detector is cooled with evaporative CO2 and is the first of its kind in ATLAS. The ATLAS IBL CO2 cooling system is designed for lower temperature operation (< ‑35oC) than the previous developed CO2 cooling systems in High Energy Physics experiments. The cold temperatures are required to protect the pixel sensors for the expected high radiation dose received at an integrated luminosity of 550 fb1. This paper describes the design, development, construction and commissioning of the IBL CO2 cooling system. It describes the challenges overcome and the important lessons learned for the development of future systems which are now under design for the Phase-II upgrade detectors.

  11. Planar n +-in-n silicon pixel sensors for the ATLAS IBL upgrade

    NASA Astrophysics Data System (ADS)

    Goessling, C.; Klingenberg, R.; Muenstermann, D.; Rummler, A.; Troska, G.; Wittig, T.

    2011-09-01

    The ATLAS experiment at the LHC is planning to upgrade its pixel detector by the installation of a 4th pixel layer, the insertable b-layer IBL with a mean sensor radius of only 32 mm from the beam axis. Being very close to the beam, the radiation damage of the IBL sensors might be as high as 5×10 15 n eq cm -2 at their end-of-life. To investigate the radiation hardness and suitability of the current ATLAS pixel sensors for IBL fluences, n +-in-n silicon pixel sensors from the ATLAS Pixel production have been irradiated by reactor neutrons to the IBL design fluence and been tested with pions at the SPS and with electrons from a 90Sr source in the laboratory. The collected charge was found to exceed 10 000 electrons per MIP at 1 kV of bias voltage which is in agreement with data collected with strip sensors. With an expected threshold of 3000-4000 electrons, this result suggests that planar n +-in-n pixel sensors are radiation hard enough to be used as IBL sensor technology.

  12. The FE-I4 Pixel Readout Chip and the IBL Module

    SciTech Connect

    Barbero, Marlon; Arutinov, David; Backhaus, Malte; Fang, Xiao-Chao; Gonella, Laura; Hemperek, Tomasz; Karagounis, Michael; Hans, Kruger; Kruth, Andre; Wermes, Norbert; Breugnon, Patrick; Fougeron, Denis; Gensolen, Fabrice; Menouni, Mohsine; Rozanov, Alexander; Beccherle, Roberto; Darbo, Giovanni; Caminada, Lea; Dube, Sourabh; Fleury, Julien; Gnani, Dario; /LBL, Berkeley /NIKHEF, Amsterdam /Gottingen U. /SLAC

    2012-05-01

    FE-I4 is the new ATLAS pixel readout chip for the upgraded ATLAS pixel detector. Designed in a CMOS 130 nm feature size process, the IC is able to withstand higher radiation levels compared to the present generation of ATLAS pixel Front-End FE-I3, and can also cope with higher hit rate. It is thus suitable for intermediate radii pixel detector layers in the High Luminosity LHC environment, but also for the inserted layer at 3.3 cm known as the 'Insertable B-Layer' project (IBL), at a shorter timescale. In this paper, an introduction to the FE-I4 will be given, focusing on test results from the first full size FE-I4A prototype which has been available since fall 2010. The IBL project will be introduced, with particular emphasis on the FE-I4-based module concept.

  13. ATLAS pixel IBL modules construction experience and developments for future upgrade

    NASA Astrophysics Data System (ADS)

    Gaudiello, A.

    2015-10-01

    The first upgrade of the ATLAS Pixel Detector is the Insertable B-Layer (IBL), installed in May 2014 in the core of ATLAS. Two different silicon sensor technologies, planar n-in-n and 3D, are used. Sensors are connected with the new generation 130 nm IBM CMOS FE-I4 read-out chip via solder bump-bonds. Production quality control tests were set up to verify and rate the performance of the modules before integration into staves. An overview of module design and construction, the quality control results and production yield will be discussed, as well as future developments foreseen for future detector upgrades.

  14. Performance Evaluation of the ATLAS IBL Calibration

    NASA Astrophysics Data System (ADS)

    Kretz, M.

    2015-12-01

    The Insertable-B-Layer (IBL) has recently been commissioned at the ATLAS Experiment, adding 12 million channels to the existing Pixel Detector. The front-end chips (FE-I4) are connected to newly designed readout hardware situated in a VME crate. In order to take data under uniform conditions, one needs to periodically tune the detector in short breaks between data-taking sessions to accommodate for radiation damage and aging effects. Tuning involves a variety of components, ranging from high-level steering and analysis software (PixLib) running on commodity hardware, to embedded components situated inside the VME crate that feature only a minimal or no operating system at all. Understanding the interactions between these components is key in debugging and optimizing the tuning procedures to become more efficient. We therefore implement an instrumentation framework aimed at all major components. It features a uniform interface to the user and is able to take instrumentation data with µs- precision. A central server application is used to gather the instrumentation data of a tuning session. It processes the data and saves it into an SQLite database for later analysis.

  15. Compute farm software for ATLAS IBL calibration

    NASA Astrophysics Data System (ADS)

    Bindi, M.; Flick, T.; Grosse-Knetter, J.; Heim, T.; Hsu, S.-C.; Kretz, M.; Kugel, A.; Marx, M.; Morettini, P.; Potamianos, K.; Takubo, Y.

    2014-06-01

    In 2014 the Insertable B-Layer (IBL) will extend the existing Pixel Detector of the ATLAS experiment at CERN by over 12 million additional pixels. For calibration and monitoring purposes, occupancy and time-over-threshold data are being histogrammed in the read-out hardware. Further processing of the histograms happens on commodity hardware, which not only requires the fast transfer of histogram data from the read-out hardware to the computing farm via Ethernet, but also the integration of the software and hardware into the already existing data-acquisition and calibration framework (TDAQ and PixelDAQ) of the ATLAS experiment and the current Pixel Detector. We implement the software running on the compute cluster with an emphasis on modularity, allowing for flexible adjustment of the infrastructure and a good scalability with respect to the number of network interfaces, available CPU cores, and deployed machines. By using a modular design we are able to not only employ CPU-based fitting algorithms, but also have the possibility to take advantage of the performance offered by a GPU-based approach to fitting.

  16. 3D active edge silicon sensors: Device processing, yield and QA for the ATLAS-IBL production

    SciTech Connect

    Da Vià, Cinzia; Boscardil, Maurizio; Dalla Betta, GianFranco; Darbo, Giovanni; Fleta, Celeste; Gemme, Claudia; Giacomini, Gabriele; Grenier, Philippe; Grinstein, Sebastian; Hansen, Thor-Erik; Hasi, Jasmine; Kenney, Christopher; Kok, Angela; La Rosa, Alessandro; Micelli, Andrea; Parker, Sherwood; Pellegrini, Giulio; Pohl, David-Leon; Povoli, Marco; Vianello, Elisa; Zorzi, Nicola; Watts, S. J.

    2013-01-01

    3D silicon sensors, where plasma micromachining is used to etch deep narrow apertures in the silicon substrate to form electrodes of PIN junctions, were successfully manufactured in facilities in Europe and USA. In 2011 the technology underwent a qualification process to establish its maturity for a medium scale production for the construction of a pixel layer for vertex detection, the Insertable B-Layer (IBL) at the CERN-LHC ATLAS experiment. The IBL collaboration, following that recommendation from the review panel, decided to complete the production of planar and 3D sensors and endorsed the proposal to build enough modules for a mixed IBL sensor scenario where 25% of 3D modules populate the forward and backward part of each stave. The production of planar sensors will also allow coverage of 100% of the IBL, in case that option was required. This paper will describe the processing strategy which allowed successful 3D sensor production, some of the Quality Assurance (QA) tests performed during the pre-production phase and the production yield to date.

  17. ATLAS Pixel Detector ROD card from IBL towards Layers 2 and 1

    NASA Astrophysics Data System (ADS)

    Balbi, G.; Falchieri, D.; Gabrielli, A.; Lama, L.; Giangiacomi, N.; Travaglini, R.

    2016-01-01

    The incoming and future upgrades of LHC will require better performance by the data acquisition system, especially in terms of throughput due to the higher luminosity that is expected. For this reason, during the first shutdown of the LHC collider in 2013/14, the ATLAS Pixel Detector has been equipped with a fourth layer— the Insertable B-Layer or IBL—located at a radius smaller than the present three layers. To read out the new layer of pixels, with a smaller pixel size with respect to the other outer layers, a front end ASIC (FE-I4) was designed as well as a new off-detector read-out chain. The latter, accordingly to the structure of the other layers of pixels, is composed mainly of two 9U-VME read-out off-detector cards called the Back-Of-Crate (BOC) and Read-Out Driver (ROD). The ROD is used for data and event formatting and for configuration and control of the overall read-out electronics. After some prototyping samples were completed, a pre-production batch of 5 ROD cards was delivered with the final layout. Another production of 15 ROD cards was done in Fall 2013, and commissioning was completed in 2014. Altogether 14 cards are necessary for the 14 staves of the IBL detector, one additional card is required by the Diamond Beam Monitor (DBM), and additional spare ROD cards were produced for a total initial batch of 20 boards. This paper describes some integration tests that were performed and our plan to install the new DAQ chain for the layer 2, which is the outermost, and layer 1, which is external to the B-layer. This latter is the only layer that will not be upgraded to a higher readout speed. Rather, it will be switched off in the near future as it has too many damaged sensors that were not possible to rework. To do that, slices of the IBL read-out chain have been instrumented, and ROD performance is verified on a test bench mimicking a small-sized final setup. Thus, this contribution reports also how the adoption of the IBL ROD for ATLAS Pixel

  18. Commissioning of the read-out driver (ROD) card for the ATLAS IBL detector and upgrade studies for the pixel Layers 1 and 2

    NASA Astrophysics Data System (ADS)

    Balbi, G.; Bindi, M.; Falchieri, D.; Gabrielli, A.; Travaglini, R.; Chen, S.-P.; Hsu, S.-C.; Hauck, S.; Kugel, A.

    2014-11-01

    The higher luminosity that is expected for the LHC after future upgrades will require better performance by the data acquisition system, especially in terms of throughput. In particular, during the first shutdown of the LHC collider in 2013/14, the ATLAS Pixel Detector will be equipped with a fourth layer - the Insertable B-Layer or IBL - located at a radius smaller than the present three layers. Consequently, a new front end ASIC (FE-I4) was designed as well as a new off-detector chain. The latter is composed mainly of two 9U-VME cards called the Back-Of-Crate (BOC) and Read-Out Driver (ROD). The ROD is used for data and event formatting and for configuration and control of the overall read-out electronics. After some prototyping samples were completed, a pre-production batch of 5 ROD cards was delivered with the final layout. Actual production of another 15 ROD cards is ongoing in Fall 2013, and commissioning is scheduled in 2014. Altogether 14 cards are necessary for the 14 staves of the IBL detector, one additional card is required by the Diamond Beam Monitor (DBM), and additional spare ROD cards will be produced for a total of 20 boards. This paper describes some integration tests that were performed and our plan to test the production of the ROD cards. Slices of the IBL read-out chain have been instrumented, and ROD performance is verified on a test bench mimicking a small-sized final setup. This contribution will report also one view on the possible adoption of the IBL ROD for ATLAS Pixel Detector Layer 2 (firstly) and, possibly, in the future, for Layer 1.

  19. Firmware development and testing of the ATLAS IBL Back Of Crate card

    NASA Astrophysics Data System (ADS)

    Stramaglia, M. E.

    2015-02-01

    ATLAS is one of the four big LHC experiments and recently its Pixel Detector was upgraded with a new innermost 4th layer: the Insertable B-Layer (IBL) . The upgrade will result in better tracking efficiency, improved precision of measurements and, in the future, compensation for radiation damage of the Pixel-Detector. Newly developed front-end electronics and the higher than originally planned LHC luminosity required a complete re-design of the Off Detector Electronics consisting of the Back Of Crate card (BOC) and the Read Out Driver (ROD) . The main purposes of the BOC card are the distribution of the LHC clock to all Pixel Detector components as well as interfacing the detector and the higher level readout optically. The data-path to the detector runs a 40 MHz bi phase mark (BPM) encoded stream. The 160 MHz 8b10b encoded data path from the detector is phase and word aligned in the firmware and then forwarded to the ROD after decoding. The ROD will send out the processed data that is then forwarded to the higher level readout by the BOC card. An overview of the newly developed firmware will be presented together with the results from production tests and the system test at CERN . Focus is put on the partial reconfiguration and results of the fine delay measurements.

  20. A PowerPC-based control system for the Read-Out-Driver module of the ATLAS IBL

    NASA Astrophysics Data System (ADS)

    Balbi, G.; Bruni, G.; Bruschi, M.; D'Antone, I.; Dopke, J.; Falchieri, D.; Flick, T.; Gabrielli, A.; Grosse-Knetter, J.; Heim, T.; Joseph, J.; Krieger, N.; Kugel, A.; Morettini, P.; Neumann, M.; Polini, A.; Schroer, N.; Rizzi, M.; Travaglini, R.; Zannoli, S.; Zoccoli, A.

    2012-02-01

    The ATLAS experiment at LHC planned to upgrade the existing Pixel Detector with the insertion of an innermost silicon layer, called Insertable B-layer (IBL). A new front-end ASIC has been foreseen (named FE-I4) and it will be read out with improved off-detector electronics. In particular, the new Read-Out Driver card (ROD) is a VME-based board designed to process a four-fold data throughput. Moreover, the ROD hosts the electronics devoted to control operations whose main tasks are providing setup busses to access configuration registers on several FPGAs, receiving configuration data from external PCs, managing triggers and running calibration procedures. In parallel with a backward-compatible solution with a Digital Signal Processor (DSP), a new ROD control circuitry with a PowerPC embedded into an FPGA has been implemented. In this paper the status of the PowerPC-based control system will be outlined with major focus on firmware and software development strategies.

  1. 3D silicon sensors: Design, large area production and quality assurance for the ATLAS IBL pixel detector upgrade

    NASA Astrophysics Data System (ADS)

    Da Via, Cinzia; Boscardin, Maurizio; Dalla Betta, Gian-Franco; Darbo, Giovanni; Fleta, Celeste; Gemme, Claudia; Grenier, Philippe; Grinstein, Sebastian; Hansen, Thor-Erik; Hasi, Jasmine; Kenney, Chris; Kok, Angela; Parker, Sherwood; Pellegrini, Giulio; Vianello, Elisa; Zorzi, Nicola

    2012-12-01

    3D silicon sensors, where electrodes penetrate the silicon substrate fully or partially, have successfully been fabricated in different processing facilities in Europe and USA. The key to 3D fabrication is the use of plasma micro-machining to etch narrow deep vertical openings allowing dopants to be diffused in and form electrodes of pin junctions. Similar openings can be used at the sensor's edge to reduce the perimeter's dead volume to as low as ˜4 μm. Since 2009 four industrial partners of the 3D ATLAS R&D Collaboration started a joint effort aimed at one common design and compatible processing strategy for the production of 3D sensors for the LHC Upgrade and in particular for the ATLAS pixel Insertable B-Layer (IBL). In this project, aimed for installation in 2013, a new layer will be inserted as close as 3.4 cm from the proton beams inside the existing pixel layers of the ATLAS experiment. The detector proximity to the interaction point will therefore require new radiation hard technologies for both sensors and front end electronics. The latter, called FE-I4, is processed at IBM and is the biggest front end of this kind ever designed with a surface of ˜4 cm2. The performance of 3D devices from several wafers was evaluated before and after bump-bonding. Key design aspects, device fabrication plans and quality assurance tests during the 3D sensors prototyping phase are discussed in this paper.

  2. Design of the ATLAS IBL Readout System

    NASA Astrophysics Data System (ADS)

    Polini, Alessandro; Bruni, Graziano; Bruschi, Marco; D'Antone, Ignazio; Dopke, Jens; Falchieri, Davide; Flick, Tobias; Gabrielli, Alessandro; Grosse-Knetter, Joern; Joseph, John; Krieger, Nina; Kugel, Andreas; Morettini, Paolo; Rizzi, Matteo; Schroer, Nicolai; Travaglini, Riccardo; Zannoli, Samuele; Zoccoli, Antonio

    An Insertable B-Layer is planned for the upgrade of the ATLAS detector and will add a fourth and innermost pixel layer to the existing Pixel Detector. 12 million pixels attached to new FE-I4 readout ASICs will require new off-detector electronics which is currently realized with two VME-based boards: a Back Of Crate module implementing optical I/O functionality and a Readout Driver module for data processing. This paper illustrates the new readout chain, focusing on the design of the new Readout Driver Card, which, with a fourfold integration with respect to the previous design, builds up the detector data, controls the calibration procedures and interacts via Gigabit links with a novel calibration farm. Future prospects and back compatibility to the existing system are also addressed.

  3. Performance tests during the ATLAS IBL Stave Integration

    NASA Astrophysics Data System (ADS)

    Jentzsch, J.

    2015-04-01

    In preparation of the ATLAS Pixel Insertable B-Layer integration, detector components, so called staves, were mounted around the Beryllium ATLAS beam pipe and tested using production quality assurance measurements as well as dedicated data taking runs to validate a correct grounding and shielding schema. Each stave consists of 32 new generation readout chips which sum up to over 860k pixels per stave. The integration tests include verification that neither the silicon planar n+-in-n nor the silicon 3D sensors were damaged by mechanical stress, and that their readout chips, including their bump-bond and wire-bond connections, did not suffer from the integration process. Evolution of the detector performance during its integration will be discussed as well as its final performance before installation.

  4. Defining the IBL and Gamma-Ray Absorption

    NASA Technical Reports Server (NTRS)

    Stecker, Floyd

    2012-01-01

    We calculate the intensity and photon spectrum of the intergalactic background light (IBL) as a function of redshift using an approach based on observational data obtained in many different wavelength bands from local to deep galaxy surveys. Our empirically based approach allows us, for the first time, to obtain a completely model independent determination of the IBL and to quantify its uncertainties. Using our results on the IBL, we then place 68% confidence upper and lower limits on the opacity of the universe to gamma-rays, independent of previous constraints that were obtained by making theoretical assumptions. We then compare our results with measurements of the extragalactic background light and upper limits obtained from observations made by the Fermi Gamma-ray Space Telescope.

  5. Perceived Usefulness and Outcomes of Intranet-Based Learning (IBL): Developing Asynchronous Knowledge Management Systems in Organizational Settings

    ERIC Educational Resources Information Center

    Lee, DongHun; Kang, Sunwoo

    2005-01-01

    This article introduces two studies showing the perceived usefulness reported by the participants of Intranet Based Learning (IBL) (N = 226) and the effectiveness of IBL measured by the outcomes of two instructional groups and the control group in a Korean private company (N = 132). It is suggested that additional aspects of IBL need to be…

  6. Modeling of ΔIBL due to random telegraph noise with considering bit-line interference in NAND flash memory

    NASA Astrophysics Data System (ADS)

    Joe, Sung-Min; Bae, Jong-Ho; Park, Chan Hyeong; Lee, Jong-Ho

    2014-12-01

    Bit-line (BL) current fluctuation (ΔIBL = high IBL - low IBL) of the trap position is modeled as a parameter of the state (program or erase) of adjacent BL cells which affects the current density distribution appreciably. To model ΔIBL, we extracted the integrated electron current density (J0 = f(z)) and the electric blockade length (Lt) by considering the effect of the interference of adjacent cells. A characteristic function (g(z)) which has a Gaussian functional form is defined based on Lt and the trap position within the tunneling oxide from the channel surface (xT). Finally, ΔIBL is extracted through the integration of f(z) and g(z). Our model predicts accurately the ΔIBL with the trap position as a parameter of the state of BL cells, showing good agreement with 3D simulation data.

  7. B Layers and Adhesion on Armco Iron Substrate

    NASA Astrophysics Data System (ADS)

    Elias-Espinosa, M.; Ortiz-Domínguez, M.; Keddam, M.; Flores-Rentería, M. A.; Damián-Mejía, O.; Zuno-Silva, J.; Hernández-Ávila, J.; Cardoso-Legorreta, E.; Arenas-Flores, A.

    2014-08-01

    In this work, a kinetic model was suggested to evaluate the boron diffusion coefficient in the Fe2B layers grown on the Armco iron substrate by the powder-pack boriding. This thermochemical treatment was carried out in the temperature range of 1123-1273 K for treatment times ranging from 2 to 8 h. The boron diffusion coefficient in the Fe2B layers was estimated by solving the mass balance equation at the (Fe2B/substrate) interface with an inclusion of boride incubation time. To validate the present model, the simulated value of Fe2B layer thickness was compared with the experimental value obtained at 1253 K for a treatment time of 5 h. The morphology of Fe2B layers was observed by SEM and optical microscopy. Metallographic studies showed that the boride layer has a saw-tooth morphology in all the samples. The layer thickness measurements were done with the help of MSQ PLUS software. The Fe2B phase was identified by x-ray diffraction method. Finally, the adherence of Fe2B layers on the Armco iron substrate was qualitatively evaluated by using the Daimler-Benz Rockwell-C indentation technique. In addition, the estimated value of boron activation energy was compared to the literature data.

  8. The trend in inquiry-based learning (IBL) research from many perspectives: A systematic review

    NASA Astrophysics Data System (ADS)

    Anuar, Nor Syuhada Binti Saiful; Sani, Siti Shamsiah Binti; Ahmad, Che Nidzam Binti Che; Damanhuri, Muhd Ibrahim Bin Muhammad; Borhan, Mohamad Termizi Bin

    2017-05-01

    Inquiry-based learning (IBL) is one of the teaching approaches that has been suggested by the Kementerian Pelajaran Malaysia (KPM). Although IBL has been in existence for many years, the effect of this approach in terms of teacher's verbal interaction during teaching has not been considered to any great extent. For this reason, a systematic review was conducted to observe the pattern of the existing IBL research. This systematic review of quantitative and qualitative studies published between 2006 and 2016 was undertaken by using the following databases: Taylor & Francis Online (2012-2015), Wiley Online Library (2012-2015), ScienceDirect, SpringerLink, SAGE Journals, and EBSCOHOST. Research articles from trustworthy websites were also used. The main keywords used were teacher verbal interaction, inquiry-based learning (IBL), secondary school science and classroom interaction. Eleven studies were included in this review but only two out of the eleven selected papers discussed teacher verbal interaction. Hence, more research needs to be conducted in order to observe the effect of IBL towards teacher's verbal interaction during learning sessions.

  9. The MV formalism for {IBL}_∞- and {BV}_∞-algebras

    NASA Astrophysics Data System (ADS)

    Markl, Martin; Voronov, Alexander A.

    2017-03-01

    We develop a new formalism for the quantum master equation Δ e^{S/\\hbar } = 0 and the category of IBL_∞-algebras and simplify some homotopical algebra arising in the context of oriented surfaces with boundary. We introduce and study a category of MV-algebras, which, on the one hand, contains such important categories as those of IBL_∞-algebras and L_∞-algebras and, on the other hand, is homotopically trivial, in particular allowing for a simple solution of the quantum master equation. We also present geometric interpretation of our results.

  10. The MV formalism for {IBL}_∞- and {BV}_∞-algebras

    NASA Astrophysics Data System (ADS)

    Markl, Martin; Voronov, Alexander A.

    2017-08-01

    We develop a new formalism for the quantum master equation Δ e^{S/\\hbar } = 0 and the category of IBL_∞-algebras and simplify some homotopical algebra arising in the context of oriented surfaces with boundary. We introduce and study a category of MV-algebras, which, on the one hand, contains such important categories as those of IBL_∞-algebras and L_∞-algebras and, on the other hand, is homotopically trivial, in particular allowing for a simple solution of the quantum master equation. We also present geometric interpretation of our results.

  11. Chop Wood, Carry Water, Use Definitions: Survival Lessons of an IBL Rookie

    ERIC Educational Resources Information Center

    Retsek, Dylan Q.

    2013-01-01

    This article describes the author's pedagogical transformation from "traditional" lecture-based instruction to Inquiry Based Learning (IBL) instruction of an introductory proofs class for sophomore mathematics majors. The story of the course overhaul follows from inception, through implementation, and ultimately to reflection.…

  12. Chop Wood, Carry Water, Use Definitions: Survival Lessons of an IBL Rookie

    ERIC Educational Resources Information Center

    Retsek, Dylan Q.

    2013-01-01

    This article describes the author's pedagogical transformation from "traditional" lecture-based instruction to Inquiry Based Learning (IBL) instruction of an introductory proofs class for sophomore mathematics majors. The story of the course overhaul follows from inception, through implementation, and ultimately to reflection.…

  13. Identification and functional analysis of cytochrome P450 complement in Streptomyces virginiae IBL14

    PubMed Central

    2013-01-01

    Background As well known, both natural and synthetic steroidal compounds are powerful endocrine disrupting compounds (EDCs) which can cause reproductive toxicity and affect cellular development in mammals and thus are generally regarded as serious contributors to water pollution. Streptomyces virginiae IBL14 is an effective degradative strain for many steroidal compounds and can also catalyze the C25 hydroxylation of diosgenin, the first-ever biotransformation found on the F-ring of diosgenin. Results To completely elucidate the hydroxylation function of cytochrome P450 genes (CYPs) found during biotransformation of steroids by S. virginiae IBL14, the whole genome sequencing of this strain was carried out via 454 Sequencing Systems. The analytical results of BLASTP showed that the strain IBL14 contains 33 CYPs, 7 ferredoxins and 3 ferredoxin reductases in its 8.0 Mb linear chromosome. CYPs from S. virginiae IBL14 are phylogenetically closed to those of Streptomyces sp. Mg1 and Streptomyces sp. C. One new subfamily was found as per the fact that the CYP Svu001 in S. virginiae IBL14 shares 66% identity only to that (ZP_05001937, protein identifer) from Streptomyces sp. Mg1. Further analysis showed that among all of the 33 CYPs in S. virginiae IBL14, three CYPs are clustered with ferredoxins, one with ferredoxin and ferredoxin reductase and three CYPs with ATP/GTP binding proteins, four CYPs arranged with transcriptional regulatory genes and one CYP located on the upstream of an ATP-binding protein and transcriptional regulators as well as four CYPs associated with other functional genes involved in secondary metabolism and degradation. Conclusions These characteristics found in CYPs from S. virginiae IBL14 show that the EXXR motif in the K-helix is not absolutely conserved in CYP157 family and I-helix not absolutely essential for the CYP structure, too. Experimental results showed that both CYP Svh01 and CYP Svu022 are two hydroxylases, capable of bioconverting

  14. Implementation and tests of FPGA-embedded PowerPC in the control system of the ATLAS IBL ROD card

    NASA Astrophysics Data System (ADS)

    Balbi, G.; Bindi, M.; Falchieri, D.; Furini, M.; Gabrielli, A.; Kugel, A.; Travaglini, R.; Wensing, M.

    2013-01-01

    The Insertable B-layer project is planned for the upgrade of the ATLAS experiment at LHC. A silicon layer will be inserted into the existing Pixel Detector together with new electronics. The readout off-detector system is implemented with a Back-Of-Crate module implementing I/O functionality and a Readout-Driver card (ROD) for data processing. The ROD hosts the electronics devoted to control operations implemented both with a back-compatible solution (using a Digital Signal Processor) and with a PowerPC embedded into an FPGA. In this document major firmware and software achievements concerning the PowerPC implementation, tested on ROD prototypes, will be reported.

  15. Enhanced decolorization of Solar brilliant red 80 textile dye by an indigenous white rot fungus Schizophyllum commune IBL-06.

    PubMed

    Asgher, Muhammad; Yasmeen, Qamar; Iqbal, Hafiz Muhammad Nasir

    2013-10-01

    An indigenously isolated white rot fungus, Schizophyllum commune IBL-06 was used to decolorize Solar brilliant red 80 direct dye in Kirk's basal salts medium. In initial screening study, the maximum decolorization (84.8%) of Solar brilliant red 80 was achieved in 7 days shaking incubation period at pH 4.5 and 30 °C. Different physical and nutritional factors including pH, temperature and fungal inoculum density were statistically optimized through Completely Randomized Design (CRD), to enhance the efficiency of S. commune IBL-06 for maximum decolorization of Solar brilliant red 80 dye. The effects of inexpensive carbon and nitrogen sources were also investigated. Percent dye decolorization was determined by a reduction in optical density at the wavelength of maximum absorbance (λ max, 590 nm). Under optimum conditions, the S. commune IBL-06 completely decolorized (100%) the Solar brilliant red 80 dye using maltose and ammonium sulfate as inexpensive carbon and nitrogen sources, respectively in 3 days. S. commune IBL-06 produced the three major ligninolytic enzymes lignin peroxidase (LiP), manganase peroxidase (MnP) and lacaase (Lac) during the decolorization of Solar brilliant red 80. LiP was the major enzyme (944 U/mL) secreted by S. commune IBL-06 along with comparatively lower activities of MnP and Laccase.

  16. Enhanced decolorization of Solar brilliant red 80 textile dye by an indigenous white rot fungus Schizophyllum commune IBL-06

    PubMed Central

    Asgher, Muhammad; Yasmeen, Qamar; Iqbal, Hafiz Muhammad Nasir

    2013-01-01

    An indigenously isolated white rot fungus, Schizophyllum commune IBL-06 was used to decolorize Solar brilliant red 80 direct dye in Kirk’s basal salts medium. In initial screening study, the maximum decolorization (84.8%) of Solar brilliant red 80 was achieved in 7 days shaking incubation period at pH 4.5 and 30 °C. Different physical and nutritional factors including pH, temperature and fungal inoculum density were statistically optimized through Completely Randomized Design (CRD), to enhance the efficiency of S. commune IBL-06 for maximum decolorization of Solar brilliant red 80 dye. The effects of inexpensive carbon and nitrogen sources were also investigated. Percent dye decolorization was determined by a reduction in optical density at the wavelength of maximum absorbance (λmax, 590 nm). Under optimum conditions, the S. commune IBL-06 completely decolorized (100%) the Solar brilliant red 80 dye using maltose and ammonium sulfate as inexpensive carbon and nitrogen sources, respectively in 3 days. S. commune IBL-06 produced the three major ligninolytic enzymes lignin peroxidase (LiP), manganase peroxidase (MnP) and lacaase (Lac) during the decolorization of Solar brilliant red 80. LiP was the major enzyme (944 U/mL) secreted by S. commune IBL-06 along with comparatively lower activities of MnP and Laccase. PMID:24235871

  17. The nocturnal IBL over an hilly island with reference to the diffusion of radioactive nuclei

    NASA Astrophysics Data System (ADS)

    Camuffo, D.

    1982-02-01

    The dynamics of the nocturnal IBL over a small hilly island on the Mediterranean Sea are discussed, particularly for clear nights characterized by light wind, when typically a nocturnal inversion may grow. Among different cases, two typical situations are observed, depending on the steadiness of the wind. In the first case the inversion alternatively grows and is eroded from aloft until it is destroyed; in the second, it grows with half the speed usual at inland sites and its height is bounded by the top of the hill. The Stüve diagrams show that the warm sea surface can supply the energy required to lift airborne pollutants over the CCL.

  18. Feeding tube insertion - gastrostomy

    MedlinePlus

    ... tube insertion; G-tube insertion; PEG tube insertion; Stomach tube insertion; Percutaneous endoscopic gastrostomy tube insertion ... and down the esophagus, which leads to the stomach. After the endoscopy tube is inserted, the skin ...

  19. Scientific evaluation of an intra-curricular educational kit to foster inquiry-based learning (IBL)

    NASA Astrophysics Data System (ADS)

    Debaes, Nathalie; Cords, Nina; Prasad, Amrita; Fischer, Robert; Euler, Manfred; Thienpont, Hugo

    2014-07-01

    Society becomes increasingly dependent on photonics technologies; however there is an alarming lack of technological awareness among secondary school students. They associate photonics with experiments and components in the class room that seem to bear little relevance to their daily life. The Rocard Report [5] highlights the need for fostering students' scientific skills and technological awareness and identifies inquiry based learning (IBL) as a means to achieve this. Students need to actively do science rather than be silent spectators. The `Photonics Explorer' kit was developed as an EU funded project to equip teachers, free-of-charge, with educational material designed to excite, engage and educate European secondary school students using guided inquiry based learning techniques. Students put together their own experiments using up-to-date versatile components, critically interpret results and relate the conclusions to relevant applications in their daily life. They work hands-on with the material, thus developing and honing their scientific and analytical skills that are otherwise latent in a typical class room situation. A qualitative and quantitative study of the impact of the kit in the classroom was undertaken with 50 kits tested in 7 EU countries with over 1500 students in the local language. This paper reports on the results of the EU wide field tests that show the positive impact of the kit in raising the self-efficacy, scientific skills and interest in science among students and the effectiveness of the kit in implementing IBL strategies in classrooms across EU.

  20. Decolorization of dye-containing textile industry effluents using Ganoderma lucidum IBL-05 in still cultures.

    PubMed

    Asgher, Muhammad; Noreen, Sadia; Bhatti, Haq Nawaz

    2010-04-01

    A locally isolated white rot fungus Ganoderma lucidum IBL-05 was used for development of a bioremediation process for original textile industry effluents. Dye-containing effluents of different colors were collected from the Arzoo (maroon), Ayesha (yellow), Ittemad (green), Crescent (navy blue) and Magna (yellowish) textile industries of Faisalabad, Pakistan. G. lucidum IBL-05 was screened for its decolorization potential on all the effluents. Maximum decolorization (49.5 %) was observed in the case of the Arzoo textile industry (ART) effluent (lambda(max) = 515 nm) on the 10th day of incubation. Therefore, the ART effluent was selected for optimization of its decolorization process. Process optimization could improve color removal efficiency of the fungus to 95% within only 2 days, catalyzed by manganese peroxidase (1295 U/mL) as the main enzyme activity at pH 3 and 35 degrees C using 1% starch supplemented Kirk's basal medium. Nitrogen addition inhibited enzyme formation and effluent decolorization. The economics and effectiveness of the process can be improved by further process optimization.

  1. Insertion Sequences

    PubMed Central

    Mahillon, Jacques; Chandler, Michael

    1998-01-01

    Insertion sequences (ISs) constitute an important component of most bacterial genomes. Over 500 individual ISs have been described in the literature to date, and many more are being discovered in the ongoing prokaryotic and eukaryotic genome-sequencing projects. The last 10 years have also seen some striking advances in our understanding of the transposition process itself. Not least of these has been the development of various in vitro transposition systems for both prokaryotic and eukaryotic elements and, for several of these, a detailed understanding of the transposition process at the chemical level. This review presents a general overview of the organization and function of insertion sequences of eubacterial, archaebacterial, and eukaryotic origins with particular emphasis on bacterial elements and on different aspects of the transposition mechanism. It also attempts to provide a framework for classification of these elements by assigning them to various families or groups. A total of 443 members of the collection have been grouped in 17 families based on combinations of the following criteria: (i) similarities in genetic organization (arrangement of open reading frames); (ii) marked identities or similarities in the enzymes which mediate the transposition reactions, the recombinases/transposases (Tpases); (iii) similar features of their ends (terminal IRs); and (iv) fate of the nucleotide sequence of their target sites (generation of a direct target duplication of determined length). A brief description of the mechanism(s) involved in the mobility of individual ISs in each family and of the structure-function relationships of the individual Tpases is included where available. PMID:9729608

  2. Chest tube insertion

    MedlinePlus

    Chest drainage tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... When your chest tube is inserted, you will lie on your side or sit partly upright, with one arm over your head. Sometimes, ...

  3. Dihalocarbene Insertion Experiment

    ERIC Educational Resources Information Center

    Goh, S. H.

    1975-01-01

    Describes the insertion reaction using the insertion of carbenes into carbon-hydrogen bonds as an example. Outlines an experiment that will illustrate dihalocarbene insertions into diisopropyl ether. (GS)

  4. Immobilized lignin peroxidase from Ganoderma lucidum IBL-05 with improved dye decolorization and cytotoxicity reduction properties.

    PubMed

    Shaheen, Raheela; Asgher, Muhammad; Hussain, Fatima; Bhatti, Haq Nawaz

    2017-10-01

    Use of free microbial enzymes for bioremediation and other industrial applications has several disadvantages like low stability and non-reusability in repeated batch operations. Immobilized enzymes are stable, recoverable and reusable in industrial processes. In this scenario G. lucidum IBL-05 LiP was entrapped in Ca-alginate beads using optimum concentrations of Na-alginate (4%), calcium chloride (0.2M) and glutraldehyde (0.02%). Optimum pH (pH 5) and temperature (55°C) for entrapped LiP were improved as compared to free LiP. Catalytic behavior of LiP also significantly enhanced, as Km value (0.25mM) decreased and Vmax value (868.6μmol/min) increased after ca-alginate entrapment of LiP. Decolorization efficiencies of Sandal reactive dyes after treating with immobilized LiP were in the range of 80-93%. A significant reduction was observed in water quality parameters including, BOD (66.44-98.22%), COD (81.34-98.82%) and TOC (80.21-97.77%) values. The cytotoxicity values for heamolytic and brine shrimp lethality of dye solutions treated with Ca-alginate immobilized LiP reduced up to 2.10-5.06% and 5.43-9.23%, respectively. On the basis of reduced toxicity and cytotoxicity values, it was concluded that Ca-alginate beads entrapped LiP may be an effective biocatalyst for bioremediation of dye based textile industry effluents. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Chair Inserts for Preschoolers.

    ERIC Educational Resources Information Center

    Horn, Eva; And Others

    1987-01-01

    The article provides detailed procedures (with diagrams) for constructing cardboard chair inserts to meet the needs of preschool children with minimal to severe physical limitations. The inserts offer reduced expense and increased flexibility allowing a customized fit. (DB)

  6. CoFeB Inserted Perpendicular Magnetic Tunnel Junctions with CoFe/Pd Multilayers for High Tunnel Magnetoresistance Ratio

    NASA Astrophysics Data System (ADS)

    Mizunuma, Kotaro; Ikeda, Shoji; Yamamoto, Hiroyuki; Gan, Hua Dong; Miura, Katsuya; Hasegawa, Haruhiro; Hayakawa, Jun; Ito, Kenchi; Matsukura, Fumihiro; Ohno, Hideo

    2010-04-01

    The effect of Co20Fe60B20 insertion on tunnel magnetoresistance (TMR) properties of MgO barrier magnetic tunnel junctions (MTJs) was studied with Co90Fe10/Pd multilayer electrodes showing perpendicular anisotropy. The TMR ratio, which depended on the sputtering power density of the CoFeB layer, reached 43% at 1.77 W/cm2 in MTJs with a 1.8-nm-thick CoFeB layer inserted on both sides of the MgO barrier. With increasing CoFeB layer thickness, the optimal annealing temperature (Ta) realizing the maximum TMR ratio increased along with the TMR ratio. The MTJs with 3.0-nm-thick CoFeB deposited at 1.77 W/cm2 showed a TMR ratio of 91% at Ta = 250 °C, where the perpendicular magnetic anisotropy is maintained.

  7. Grommet Having Metal Insert

    DTIC Science & Technology

    1998-09-28

    axially with respect to the body. The 1 means for releasably securing a tool to the insert comprises 2 female threads formed on an inner surface of the...below 10 the flange 32. These surfaces 34, 36 are threaded ( female 11 threads) so that the end of a tool 38 having male threads can 12 engage the...further includes a rigid insert secured to the body in the 12 centrally located aperture. The insert has female threads formed 13 therein for releasably

  8. Phanerochaete chrysosporium IBL-03 secretes high titers of manganese peroxidase during decolorization of Drimarine Blue K2RL textile dye.

    PubMed

    Noreen, Razia; Asgher, Muhammad; Bhatti, Haq Nawaz; Batool, Shaheera; Asad, Muhammad Javaid

    2011-01-01

    A novel indigenous strain, Phanerochaete chrysosporium IBL-03, with high manganese peroxidase (MnP) activities was used for decolorization of a reactive textile dye, Drimarine Blue K2R, which is used extensively in textile units of Pakistan. The initial experiment was run for seven days with 0.01% (w/v) dye solution prepared in Kirk's basal nutrient medium. Samples were removed after every 24 h and the extent of dye decolorization was determined at lambda(max) of the dye. The study revealed that P. chrysosporium caused 65% decolorization of Drimarine Blue K2RL in seven days. By process optimization, 97% colour removal could be achieved in three days using 0.005% (w/v) Drimarine Blue K2RL solution at pH 4.0 and 30 degrees C in defined Kirk's medium with 0.9% (w/v) molasses and 0.2% (w/v) ammonium dihydrogen phosphate added as carbon and nitrogen sources, respectively. Manganese peroxidase was found to be the major enzyme (560 IU/mL) involved in dye decolorization of Drimarine Blue K2RL by P. chrysosporium. The dye adsorption studies showed that the dye initially adsorbed on fungal mats disappeared later on, possibly by the action of MnP secreted by the fungus in secondary metabolism.

  9. Plastic pipe insertion

    SciTech Connect

    Diskin, J.

    1987-05-01

    In March 1987 KPL changed all that when the utility inserted 1,000 ft of 16-in. SDR 15.5 Phillips Driscopipe 8000 pipe with a wall thickness of 1.032-in., into an abandoned 24-in. cast-iron line in downtown Kansas City. This is believed to be the largest diameter insert removal job ever done for gas distribution in the U.S. For KPL it was a natural progression from the smaller sizes used earlier. The procedure is the same, and the operation was quick and comparatively simple. Lower construction costs were the bottom line because with insert renewal there is no need to cut up the streets, a major expense in any urban pipeline work. There are other significant costs savings as well because the insert renewal construction process is faster than other techniques.

  10. Ear tube insertion - slideshow

    MedlinePlus

    ... this page: //medlineplus.gov/ency/presentations/100045.htm Ear tube insertion - series—Normal anatomy To use the ... 4 Overview The eardrum (tympanic membrane) separates the ear canal from the middle ear. Review Date 8/ ...

  11. An analytical kinetic model for chemical-vapor deposition of pureB layers from diborane

    NASA Astrophysics Data System (ADS)

    Mohammadi, V.; de Boer, W. B.; Nanver, L. K.

    2012-12-01

    In this paper, an analytical model is established to describe the deposition kinetics and the deposition chamber characteristics that determine the deposition rates of pure boron (PureB-) layers grown by chemical-vapor deposition (CVD) from diborane (B2H6) as gas source on a non-rotating silicon wafer. The model takes into consideration the diffusion mechanism of the diborane species through the stationary boundary layer over the wafer, the gas phase processes and the related surface reactions by applying the actual parabolic gas velocity and temperature gradient profiles in the reactor. These are calculated theoretically and also simulated with fluent software. The influence of an axial and lateral diffusion of diborane species and the validity of the model for laminar flow in experimental CVD processes are also treated. This model is based on a wide range of input parameters, such as initial diborane partial pressure, total gas flow, axial position on the wafer, deposition temperature, activation energy of PureB deposition from diborane, surface H-coverage, and reactor dimensions. By only adjusting these reactor/process parameters, the model was successfully transferred from the ASM Epsilon One to the Epsilon 2000 reactor which has totally different reactor conditions. The model's predictive capabilities have been verified by experiments performed at 700 °C in these two different ASM CVD reactors.

  12. ALS insertion devices

    NASA Astrophysics Data System (ADS)

    Hoyer, E.; Chin, J.; Halbach, K.; Hassenzahl, W. V.; Humphries, D.; Kincaid, B.; Lancaster, H.; Plate, D.

    1991-08-01

    The Advanced Light Source (ALS), the first US third generation synchrotron radiation source, is currently under construction at the Lawrence Berkeley Laboratory. The low-emittance, 1.5 GeV electron storage ring and the insertion devices are specifically designed to produce high brightness beams in the UV to soft X-Ray range. The planned initial complement of insertion devices includes four 4.6 m long undulators, with period lengths of 3.9 cm, 5.0 cm (2) and 8.0 cm, and a 2.9 m long wiggler of 16 cm period length. Undulator design is well advanced and fabrication has begun on the 5.0 cm and 8.0 cm period length undulators. This paper discusses ALS insertion device requirements; general design philosophy; and design of the magnetic structure, support structure/drive systems, control system and vacuum system.

  13. Characterization of P450 FcpC, the Enzyme Responsible for Bioconversion of Diosgenone to Isonuatigenone in Streptomyces virginiae IBL-14▿ †

    PubMed Central

    Wang, Wei; Wang, Feng-Qing; Wei, Dong-Zhi

    2009-01-01

    A new cytochrome P450 monooxygenase, FcpC, from Streptomyces virginiae IBL-14 has been identified. This enzyme is found to be responsible for the bioconversion of a pyrano-spiro steroid (diosgenone) to a rare nuatigenin-type spiro steroid (isonuatigenone), which is a novel C-25-hydroxylated diosgenone derivative. A whole-cell P450 system was developed for the production of isonuatigenone via the expression of the complete three-component electron transfer chain in an Escherichia coli strain. PMID:19376895

  14. Insertion in Persian

    ERIC Educational Resources Information Center

    Kambuziya, Aliyeh Kord-e Zafaranlu; Dehghan, Masoud

    2011-01-01

    This paper investigates epenthesis process in Persian to catch some results in relating to vowel and consonant insertion in Persian lexicon. This survey has a close relationship to the description of epenthetic consonants and the conditions in which these consonants are used. Since no word in Persian may begin with a vowel, so that hiatus can't be…

  15. MELFI Sample Insertion

    NASA Image and Video Library

    2010-06-28

    ISS024-E-006699 (28 June 2010) --- NASA astronaut Doug Wheelock, Expedition 24 flight engineer, prepares to insert biological samples into trays in the Minus Eighty Laboratory Freezer for ISS-2 (MELFI-2) in the Destiny laboratory of the International Space Station.

  16. MELFI Sample Insertion

    NASA Image and Video Library

    2010-07-02

    ISS024-E-007346 (2 July 2010) --- NASA astronauts Tracy Caldwell Dyson (background) and Shannon Walker, both Expedition 24 flight engineers, prepare to insert biological samples in a dewar tray in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.

  17. MELFI Sample Insertion

    NASA Image and Video Library

    2010-06-28

    ISS024-E-006697 (28 June 2010) --- NASA astronaut Doug Wheelock, Expedition 24 flight engineer, prepares to insert biological samples into trays in the Minus Eighty Laboratory Freezer for ISS-2 (MELFI-2) in the Destiny laboratory of the International Space Station.

  18. High Speed Video Insertion

    NASA Astrophysics Data System (ADS)

    Janess, Don C.

    1984-11-01

    This paper describes a means of inserting alphanumeric characters and graphics into a high speed video signal and locking that signal to an IRIG B time code. A model V-91 IRIG processor, developed by Instrumentation Technology Systems under contract to Instrumentation Marketing Corporation has been designed to operate in conjunction with the NAC model FHS-200 High Speed Video Camera which operates at 200 fields per second. The system provides for synchronizing the vertical and horizontal drive signals such that the vertical sync precisely coincides with five millisecond transitions in the IRIG time code. Additionally, the unit allows for the insertion of an IRIG time message as well as other data and symbols.

  19. Thought Insertion Clarified

    PubMed Central

    Ratcliffe, Matthew; Wilkinson, Sam

    2016-01-01

    ‘Thought insertion’ in schizophrenia involves somehow experiencing one’s own thoughts as someone else’s. Some philosophers try to make sense of this by distinguishing between ownership and agency: one still experiences oneself as the owner of an inserted thought but attributes it to another agency. In this paper, we propose that thought insertion involves experiencing thought contents as alien, rather than episodes of thinking. To make our case, we compare thought insertion to certain experiences of ‘verbal hallucination’ and show that they amount to different descriptions of the same phenomenon: a quasi-perceptual experience of thought content. We add that the agency/ownership distinction is unhelpful here. What requires explanation is not why a person experiences a type of intentional state without the usual sense of agency, but why she experiences herself as the agent of one type of intentional state rather than another. We conclude by sketching an account of how this might happen. PMID:28123340

  20. Characterization of purified and Xerogel immobilized Novel Lignin Peroxidase produced from Trametes versicolor IBL-04 using solid state medium of Corncobs

    PubMed Central

    2012-01-01

    Background Cost-effective production of industrially important enzymes is a key for their successful exploitation on industrial scale. Keeping in view the extensive industrial applications of lignin peroxidase (LiP), this study was performed to purify and characterize the LiP from an indigenous strain of Trametes versicolor IBL-04. Xerogel matrix enzyme immobilization technique was applied to improve the kinetic and thermo-stability characteristics of LiP to fulfil the requirements of the modern enzyme consumer sector of biotechnology. Results A novel LiP was isolated from an indigenous T. versicolor IBL-04 strain. T. versicolor IBL-04 was cultured in solid state fermentation (SSF) medium of corn cobs and maximum LiP activity of 592 ± 6 U/mL was recorded after five days of incubation under optimum culture conditions. The crude LiP was 3.3-fold purified with specific activity of 553 U/mg after passing through the DEAE-cellulose and Sephadex-G-100 chromatography columns. The purified LiP exhibited a relatively low molecular weight (30 kDa) homogenous single band on native and SDS-PAGE. The LiP was immobilized by entrapping in xerogel matrix of trimethoxysilane (TMOS) and proplytetramethoxysilane (PTMS) and maximum immobilization efficiency of 88.6% was achieved. The free and immobilized LiPs were characterized and the results showed that the free and immobilized LiPs had optimum pH 6 and 5 while optimum temperatures were 60°C and 80°C, respectively. Immobilization was found to enhance the activity and thermo-stability potential of LiP significantly and immobilized LiP remained stable over broad pH and temperature range as compare to free enzyme. Kinetic constants Km and Vmax were 70 and 56 μM and 588 and 417 U/mg for the free and immobilized LiPs, respectively. Activity of this novel extra thermo-stable LiP was stimulated to variable extents by Cu2+, Mn2+ and Fe2+ whereas, Cystein, EDTA and Ag+ showed inhibitory effects. Conclusions The indigenously

  1. Timing of the IUD insertion.

    PubMed

    Edelman, D A; Zipper, J; Rivera, M; Medel, M

    1979-05-01

    The relationship between the time in the menstrual cycle when a TCu-200 or Cu-7-200 is inserted and subsequent IUD-related events was evaluated. For women who had either TCus or Cu-7s inserted, the pregnancy, expulsion and medical removal rates were similar for insertions performed at any time of the menstrual cycle.

  2. Improvement of Catalytic Efficiency, Thermo-stability and Dye Decolorization Capability of Pleurotus ostreatus IBL-02 laccase by Hydrophobic Sol Gel Entrapment

    PubMed Central

    2012-01-01

    Background In serious consideration of the worldwide environmental issues associated with the extensive use of the textile dyes and effluents generated thereof, the scientists across the world are in search for potential treatment technologies for their treatment. In such scenario the ligninolytic enzymes provide a potential alternative because they are cost effective, eco-friendly and can be applied to wide range of dye containing industrial effluents. Results Laccase produced from Pleurotus ostreatus IBL-02 during decolorization of the reactive textile dye Drimarene brilliant red K-4BL (DBR K-4BL) was purified and immobilized by hydrophobic gel entrapment. The crude laccase was 4.2-fold purified with specific activity of 573.52 U/mg after passing through the DEAE-Sepharose ion exchange and Sephadex-G-100 chromatography columns. P. ostreatus IBL-02 laccase was found to be a homogenous monomeric protein as evident by single band corresponding to 67 kDa on native and sodium dodesylsulfate polyacrylamide gel electrophoresis (PAGE). The laccase was immobilized by entrapment in Sol–gel matrix of trimethoxysilane (T) and proplytetramethoxysilane (P) prepared using different T:P molar ratios. The free and immobilized laccases were compared to investigate the effect of immobilization on catalytic efficiency and thermo-stability features. Laccase immobilized in the Sol–gel of 1:5 T:P ratio was optimally active and thermo-stable fraction at pH 5, 60°C with half-life of 3 h and 50 min. Laccases immobilized in 1:2 and 1:5 T:P ratio gels had significantly higher Km (83 and100mM) and Vmax (1000 and 1111 mM/mg) values as compared to free laccase. After 5 h reaction time varying decolorization percentages with a maximum of 100% were achieved for different dyes and effluents. Conclusions In summary, P. ostreatus IBL-02 laccase was immobilized by entrapping in a Sol–gel matrix with an objective to enhance its catalytic and stability properties. Sol–gel entrapped laccase

  3. Physics performance of the ATLAS pixel detector

    NASA Astrophysics Data System (ADS)

    Tsuno, S.

    2017-01-01

    In preparation for LHC Run-2 the ATLAS detector introduced a new pixel detector, the Insertable B-Layer (IBL). This detector is located between the beampipe and what was the innermost pixel layer. The tracking and vertex reconstruction are significantly improved and good performance is expected in high level objects such a b-quark jet tagging. This in turn, leads to better physics results. This note summarizes the impact of the IBL detector on physics results, especially focusing on the analyses using b-quark jets throughout 2016 summer physics program.

  4. Metal and cofactor insertion.

    PubMed

    Mendel, Ralf R; Smith, Alison G; Marquet, Andree; Warren, Martin J

    2007-10-01

    Cells require metal ions as cofactors for the assembly of metalloproteins. Principally one has to distinguish between metal ions that are directly incorporated into their cognate sites on proteins and those metal ions that have to become part of prosthetic groups, cofactors or complexes prior to insertion of theses moieties into target proteins. Molybdenum is only active as part of the molybdenum cofactor, iron can be part of diverse Fe-S clusters or of the heme group, while copper ions are directly delivered to their targets. We will focus in greater detail on molybdenum metabolism because molybdenum metabolism is a good example for demonstrating the role and the network of metals in metabolism: each of the three steps in the pathway of molybdenum cofactor formation depends on a different metal (iron, copper, molybdenum) and also the enzymes finally harbouring the molybdenum cofactor need additional metal-containing groups to function (iron sulfur-clusters, heme-iron).

  5. Optimization of perpendicular anisotropy of Ta-inserted double CoFeB/MgO interface MTJ's for STT-MRAM

    NASA Astrophysics Data System (ADS)

    Clark, Billy D.; Paul, Soumalya; Schwarm, Samuel C.; Singh, Amritpal; Natarajarathinam, Anusha; Gupta, Subhadra

    2016-01-01

    Ta inserts in double magnetic tunnel junctions have been shown to induce perpendicular magnetic anisotropy. We fabricated the central layers of a CoFeB/MgO based double magnetic tunnel junction with a Ta insertion layer between the free layers of the magnetic tunnel junctions. The thickness of the Ta insert and CoFeB layer were varied from 0.5 to 1.1 nm and 0.9 to 1.7 nm respectively, to find which minimum thickness of Ta will induce perpendicular anisotropy in the MTJ. FMR studies were performed to measure the interfacial anisotropy Ku,i. We demonstrated that the most effective stack minimized the CoFeB thickness while maximizing the Ta thickness. This was balanced with the need to keep both CoFeB layers from decoupling or becoming magnetically dead.

  6. Facility target insert shielding assessment

    SciTech Connect

    Mocko, Michal

    2015-10-06

    Main objective of this report is to assess the basic shielding requirements for the vertical target insert and retrieval port. We used the baseline design for the vertical target insert in our calculations. The insert sits in the 12”-diameter cylindrical shaft extending from the service alley in the top floor of the facility all the way down to the target location. The target retrieval mechanism is a long rod with the target assembly attached and running the entire length of the vertical shaft. The insert also houses the helium cooling supply and return lines each with 2” diameter. In the present study we focused on calculating the neutron and photon dose rate fields on top of the target insert/retrieval mechanism in the service alley. Additionally, we studied a few prototypical configurations of the shielding layers in the vertical insert as well as on the top.

  7. Impedance calculation for ferrite inserts

    SciTech Connect

    Breitzmann, S.C.; Lee, S.Y.; Ng, K.Y.; /Fermilab

    2005-01-01

    Passive ferrite inserts were used to compensate the space charge impedance in high intensity space charge dominated accelerators. They study the narrowband longitudinal impedance of these ferrite inserts. they find that the shunt impedance and the quality factor for ferrite inserts are inversely proportional to the imaginary part of the permeability of ferrite materials. They also provide a recipe for attaining a truly passive space charge impedance compensation and avoiding narrowband microwave instabilities.

  8. Mechanisms for Complex Chromosomal Insertions

    PubMed Central

    Szafranski, Przemyslaw; Akdemir, Zeynep Coban; Yuan, Bo; Cooper, Mitchell L.; Magriñá, Maria A.; Bacino, Carlos A.; Lalani, Seema R.; Patel, Ankita; Song, Rodger H.; Bi, Weimin; Cheung, Sau Wai; Carvalho, Claudia M. B.; Lupski, James R.

    2016-01-01

    Chromosomal insertions are genomic rearrangements with a chromosome segment inserted into a non-homologous chromosome or a non-adjacent locus on the same chromosome or the other homologue, constituting ~2% of nonrecurrent copy-number gains. Little is known about the molecular mechanisms of their formation. We identified 16 individuals with complex insertions among 56,000 individuals tested at Baylor Genetics using clinical array comparative genomic hybridization (aCGH) and fluorescence in situ hybridization (FISH). Custom high-density aCGH was performed on 10 individuals with available DNA, and breakpoint junctions were fine-mapped at nucleotide resolution by long-range PCR and DNA sequencing in 6 individuals to glean insights into potential mechanisms of formation. We observed microhomologies and templated insertions at the breakpoint junctions, resembling the breakpoint junction signatures found in complex genomic rearrangements generated by replication-based mechanism(s) with iterative template switches. In addition, we analyzed 5 families with apparently balanced insertion in one parent detected by FISH analysis and found that 3 parents had additional small copy-number variants (CNVs) at one or both sides of the inserting fragments as well as at the inserted sites. We propose that replicative repair can result in interchromosomal complex insertions generated through chromothripsis-like chromoanasynthesis involving two or three chromosomes, and cause a significant fraction of apparently balanced insertions harboring small flanking CNVs. PMID:27880765

  9. Mechanisms for Complex Chromosomal Insertions.

    PubMed

    Gu, Shen; Szafranski, Przemyslaw; Akdemir, Zeynep Coban; Yuan, Bo; Cooper, Mitchell L; Magriñá, Maria A; Bacino, Carlos A; Lalani, Seema R; Breman, Amy M; Smith, Janice L; Patel, Ankita; Song, Rodger H; Bi, Weimin; Cheung, Sau Wai; Carvalho, Claudia M B; Stankiewicz, Paweł; Lupski, James R

    2016-11-01

    Chromosomal insertions are genomic rearrangements with a chromosome segment inserted into a non-homologous chromosome or a non-adjacent locus on the same chromosome or the other homologue, constituting ~2% of nonrecurrent copy-number gains. Little is known about the molecular mechanisms of their formation. We identified 16 individuals with complex insertions among 56,000 individuals tested at Baylor Genetics using clinical array comparative genomic hybridization (aCGH) and fluorescence in situ hybridization (FISH). Custom high-density aCGH was performed on 10 individuals with available DNA, and breakpoint junctions were fine-mapped at nucleotide resolution by long-range PCR and DNA sequencing in 6 individuals to glean insights into potential mechanisms of formation. We observed microhomologies and templated insertions at the breakpoint junctions, resembling the breakpoint junction signatures found in complex genomic rearrangements generated by replication-based mechanism(s) with iterative template switches. In addition, we analyzed 5 families with apparently balanced insertion in one parent detected by FISH analysis and found that 3 parents had additional small copy-number variants (CNVs) at one or both sides of the inserting fragments as well as at the inserted sites. We propose that replicative repair can result in interchromosomal complex insertions generated through chromothripsis-like chromoanasynthesis involving two or three chromosomes, and cause a significant fraction of apparently balanced insertions harboring small flanking CNVs.

  10. Insertion device and method for accurate and repeatable target insertion

    DOEpatents

    Gubeli, III, Joseph F.; Shinn, Michelle D.; Bevins, Michael E.; Dillon-Townes, Lawrence; Neil, George R.

    2017-07-04

    The present invention discloses a device and a method for inserting and positioning a target within a free electron laser, particle accelerator, or other such device that generates or utilizes a beam of energy or particles. The system includes a three-point registration mechanism that insures angular and translational accuracy and repeatability of positioning upon multiple insertions within the same structure.

  11. Comparison of intramenstrual IUD insertion with insertion following menstrual regulation.

    PubMed

    Otolorin, E O; Ladipo, O A

    1985-03-01

    To evaluate the use-effectiveness and safety of IUD insertion immediately after menstrual regulation (MR) for delayed menses, a Lippes Loop D (LLD) intrauterine device was inserted in each of 100 consecutive clients at the University College Hospital, Ibadan, immediately after menstrual regulation. Pertinent event rates after 12 months of use were compared with those of 100 consecutive women who had the LLD inserted during menstruation. The cumulative net expulsion rate after 12 months of use was 8% for the study group and 4% for the controls. The overall rate of removals was 15% for the study group and 16% for the control group. None of the observed differences was statistically significant. The continuation rates at 12 months were comparable for both groups (78% and 80%, respectively). There were no accidental pregnancies during the study period. The authors suggest that IUD insertion immediately after menstrual regulation is as effective and safe as intramenstrual insertion, provided prophylactic antibiotics are given.

  12. Sink Inserts for Flood Prevention

    NASA Astrophysics Data System (ADS)

    Fleming, Fraser F.; Bodnar, Daniel J.; Hardesty, David L.

    2004-09-01

    A simple, inexpensive insert is described for preventing flooding in lab sinks. The insert is essentially a tube with slots cut into the side that fits snugly into the drain outlet, preventing water buildup and providing additional drainage sites to avoid constriction by small lab items and paper towels.

  13. Tool Removes Coil-Spring Thread Inserts

    NASA Technical Reports Server (NTRS)

    Collins, Gerald J., Jr.; Swenson, Gary J.; Mcclellan, J. Scott

    1991-01-01

    Tool removes coil-spring thread inserts from threaded holes. Threads into hole, pries insert loose, grips insert, then pulls insert to thread it out of hole. Effects essentially reverse of insertion process to ease removal and avoid further damage to threaded inner surface of hole.

  14. Non-insertional Achilles tendinopathy

    PubMed Central

    Pearce, Christopher J.; Tan, Audrey

    2016-01-01

    Non-insertional Achilles tendinopathy is a degenerative condition characterised by pain on activity. Eccentric stretching is the most effective treatment. Surgical treatment is reserved for recalcitrant cases. Minimally-invasive and tendinoscopic treatments are showing promising results. Cite this article: Pearce CJ, Tan A. Non-insertional Achilles tendinopathy. EFORT Open Rev 2016;1:383-390. DOI: 10.1302/2058-5241.1.160024. PMID:28461917

  15. Genome-wide SNP discovery and QTL mapping for fruit quality traits in inbred backcross lines (IBLs) of solanum pimpinellifolium using genotyping by sequencing.

    PubMed

    Celik, Ibrahim; Gurbuz, Nergiz; Uncu, Ali Tevfik; Frary, Anne; Doganlar, Sami

    2017-01-03

    Solanum pimpinellifolium has high breeding potential for fruit quality traits and has been used as a donor in tomato breeding programs. Unlocking the genetic potential of S. pimpinellifolium requires high-throughput polymorphism identification protocols for QTL mapping and introgression of favourable alleles into cultivated tomato by both positive and background selection. In this study we identified SNP loci using a genotyping by sequencing (GBS) approach in an IBL mapping population derived from the cross between a high yielding fresh market tomato and S. pimpinellifolium (LA1589) as the recurrent and donor parents, respectively. A total of 120,983,088 reads were generated by the Illumina HiSeq next-generation sequencing platform. From these reads 448,539 sequence tags were generated. A majority of the sequence tags (84.4%) were uniquely aligned to the tomato genome. A total of 3.125 unique SNP loci were identified as a result of tag alignment to the genome assembly and were used in QTL analysis of 11 fruit quality traits. As a result, 37 QTLs were identified. S. pimpinellifolium contributed favourable alleles for 16 QTLs (43.2%), thus confirming the high breeding potential of this wild species. The present work introduced a set of SNPs at sufficiently high density for QTL mapping in populations derived from S. pimpinellifolium (LA1589). Moreover, this study demonstrated the high efficiency of the GBS approach for SNP identification, genotyping and QTL mapping in an interspecific tomato population.

  16. Evidence of a reduction reaction of oxidized iron/cobalt by boron atoms diffused toward naturally oxidized surface of CoFeB layer during annealing

    SciTech Connect

    Sato, Soshi Honjo, Hiroaki; Niwa, Masaaki; Ikeda, Shoji; Ohno, Hideo; Endoh, Tetsuo

    2015-04-06

    We have investigated the redox reaction on the surface of Ta/CoFeB/MgO/CoFeB magnetic tunnel junction stack samples after annealing at 300, 350, and 400 °C for 1 h using angle-resolved X-ray photoelectron spectroscopy for precise analysis of the chemical bonding states. At a capping tantalum layer thickness of 1 nm, both the capping tantalum layer and the surface of the underneath CoFeB layer in the as-deposited stack sample were naturally oxidized. By comparison of the Co 2p and Fe 2p spectra among the as-deposited and annealed samples, reduction of the naturally oxidized cobalt and iron atoms occurred on the surface of the CoFeB layer. The reduction reaction was more significant at higher annealing temperature. Oxidized cobalt and iron were reduced by boron atoms that diffused toward the surface of the top CoFeB layer. A single CoFeB layer was prepared on SiO{sub 2}, and a confirmatory evidence of the redox reaction with boron diffusion was obtained by angle-resolved X-ray photoelectron spectroscopy analysis of the naturally oxidized surface of the CoFeB single layer after annealing. The redox reaction is theoretically reasonable based on the Ellingham diagram.

  17. Evidence of a reduction reaction of oxidized iron/cobalt by boron atoms diffused toward naturally oxidized surface of CoFeB layer during annealing

    NASA Astrophysics Data System (ADS)

    Sato, Soshi; Honjo, Hiroaki; Ikeda, Shoji; Ohno, Hideo; Endoh, Tetsuo; Niwa, Masaaki

    2015-04-01

    We have investigated the redox reaction on the surface of Ta/CoFeB/MgO/CoFeB magnetic tunnel junction stack samples after annealing at 300, 350, and 400 °C for 1 h using angle-resolved X-ray photoelectron spectroscopy for precise analysis of the chemical bonding states. At a capping tantalum layer thickness of 1 nm, both the capping tantalum layer and the surface of the underneath CoFeB layer in the as-deposited stack sample were naturally oxidized. By comparison of the Co 2p and Fe 2p spectra among the as-deposited and annealed samples, reduction of the naturally oxidized cobalt and iron atoms occurred on the surface of the CoFeB layer. The reduction reaction was more significant at higher annealing temperature. Oxidized cobalt and iron were reduced by boron atoms that diffused toward the surface of the top CoFeB layer. A single CoFeB layer was prepared on SiO2, and a confirmatory evidence of the redox reaction with boron diffusion was obtained by angle-resolved X-ray photoelectron spectroscopy analysis of the naturally oxidized surface of the CoFeB single layer after annealing. The redox reaction is theoretically reasonable based on the Ellingham diagram.

  18. Gene Insertion Patterns and Sites

    NASA Astrophysics Data System (ADS)

    Vain, Philippe; Thole, Vera

    During the past 25 years, the molecular analysis of transgene insertion patterns and sites in plants has greatly contributed to our understanding of the mechanisms underlying transgene integration, expression, and stability in the nuclear genome. Molecular characterization is also an essential step in the safety assessment of genetically modified crops. This chapter describes the standard experimental procedures used to analyze transgene insertion patterns and loci in cereals and grasses transformed using Agrobacterium tumefaciens or direct transfer of DNA. Methods and protocols enabling the determination of the number and configuration of transgenic loci via a combination of inheritance studies, polymerase chain reaction, and Southern analyses are presented. The complete characterization of transgenic inserts in plants is, however, a holistic process relying on a wide variety of experimental approaches. In this chapter, these additional approaches are not detailed but references to relevant bibliographic records are provided.

  19. MELFI Urine Sample First Insertion

    NASA Image and Video Library

    2009-04-11

    ISS019-E-005715 (11 April 2009) --- Astronaut Michael Barratt, Expedition 19/20 flight engineer, performs an insertion of urine samples into the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) study in the Japanese Kibo laboratory of the International Space Station.

  20. Insertion device calculations with mathematica

    SciTech Connect

    Carr, R.; Lidia, S.

    1995-02-01

    The design of accelerator insertion devices such as wigglers and undulators has usually been aided by numerical modeling on digital computers, using code in high level languages like Fortran. In the present era, there are higher level programming environments like IDL{reg_sign}, MatLab{reg_sign}, and Mathematica{reg_sign} in which these calculations may be performed by writing much less code, and in which standard mathematical techniques are very easily used. The authors present a suite of standard insertion device modeling routines in Mathematica to illustrate the new techniques. These routines include a simple way to generate magnetic fields using blocks of CSEM materials, trajectory solutions from the Lorentz force equations for given magnetic fields, Bessel function calculations of radiation for wigglers and undulators and general radiation calculations for undulators.

  1. Ultrasound guided spine needle insertion

    NASA Astrophysics Data System (ADS)

    Chen, Elvis C. S.; Mousavi, Parvin; Gill, Sean; Fichtinger, Gabor; Abolmaesumi, Purang

    2010-02-01

    An ultrasound (US) guided, CT augmented, spine needle insertion navigational system is introduced. The system consists of an electromagnetic (EM) sensor, an US machine, and a preoperative CT volume of the patient anatomy. Three-dimensional (3D) US volume is reconstructed intraoperatively from a set of two-dimensional (2D) freehand US slices, and is coregistered with the preoperative CT. This allows the preoperative CT volume to be used in the intraoperative clinical coordinate. The spatial relationship between the patient anatomy, surgical tools, and the US transducer are tracked using the EM sensor, and are displayed with respect to the CT volume. The pose of the US transducer is used to interpolate the CT volume, providing the physician with a 2D "x-ray vision" to guide the needle insertion. Many of the system software components are GPU-accelerated, allowing real-time performance of the guidance system in a clinical setting.

  2. Inserting Agility in System Development

    DTIC Science & Technology

    2012-07-01

    Agile IT Acquisition, IT Box, Scrum Inserting Agility in System Development Matthew R. Kennedy and Lt Col Dan Ward, USAF With the fast-paced nature...1,700 individuals and 71 countries, found Scrum and eXtreme Programming to be the most widely followed method- ologies (VersionOne, 2007). Other...University http://www.dau.mil 259 Defense ARJ, July 2012, Vol. 19 No. 3 : 249–264 Scrum Scrum is a framework used for project management, which is

  3. Field errors in hybrid insertion devices

    SciTech Connect

    Schlueter, R.D.

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed.

  4. Insert metering plates for gas turbine nozzles

    DOEpatents

    Burdgick, Steven S.; Itzel, Gary; Chopra, Sanjay; Abuaf, Nesim; Correia, Victor H.

    2004-05-11

    The invention comprises a metering plate which is assembled to an impingement insert for use in the nozzle of a gas turbine. The metering plate can have one or more metering holes and is used to balance the cooling flow within the nozzle. A metering plate with multiple holes reduces static pressure variations which result from the cooling airflow through the metering plate. The metering plate can be assembled to the insert before or after the insert is inserted into the nozzle.

  5. Ketamine improves nasogastric tube insertion.

    PubMed

    Nejati, Amir; Golshani, Keihan; Moradi Lakeh, Maziar; Khashayar, Patricia; Moharari, Reza Shariat

    2010-08-01

    Nasogastric (NG) intubation is one of the most common procedures performed in the emergency department (ED) and other hospital settings. The aim of this study was to compare the level of pain during NG tube insertion in groups receiving local ketamine plus water-soluble lubricating gel and water-soluble lubricating gel alone (the latter is the common practice in our hospital). It was hypothesised that ketamine has local anaesthetic effects in reducing the pain of NG tube insertion in the ED. This prospective double-blind randomised clinical trial was performed on alert haemodynamically stable subjects aged >18 years who required NG tube placement for diagnostic or therapeutic purposes in the ED of a teaching hospital during January and June 2008. The subjects were divided into two groups using randomised allocation software. The ketamine group received intranasal ketamine, while an equivalent volume of sterile water was instilled into the nasal cavity in the control group. The same amount of lubricating gel was used in both groups. The pain of NG tube placement was measured using a standard 100 mm visual analogue scale (VAS). The physician was asked to evaluate the difficulty of the procedure using a 5-point Likert scale. Seventy-two subjects were enrolled in the study (36 subjects in each group). There was a significant difference between the pain score of the ketamine and control groups (19.03+/-3.56 vs 33.33+/-5.31), while the difficulty score was not statistically different between the two groups (2.39+/-1.25 vs 2.78+/-1.56). Intranasal ketamine is an effective agent in reducing pain during NG tube insertion among patients without serious underlying illness.

  6. JT/LJT connector insert material evaluation

    SciTech Connect

    Baca, J.R.F.

    1991-10-01

    Different insert (insulator) materials are undergoing evaluation to replace the Fiberite E-3938 BE96 material currently used. Also being evaluated is the reconfiguration of the insert and metal shell-edge geometries for the purpose of reducing the alleged interference principally responsible for insert damage.

  7. Insert earphone depth and the occlusion effect.

    PubMed

    Dean, M S; Martin, F N

    2000-12-01

    Twenty individuals were tested to determine the occlusion effect caused by supraaural earphones and by insert earphones with shallow and deep insertion of its foam eartip. The bone-conduction oscillator was placed both on the forehead and the mastoid. It was concluded that using deeply inserted earphones is the most practical way in which to carry out clinical bone-conduction measurements.

  8. Analysis of inserts in prokaryote genomes

    NASA Astrophysics Data System (ADS)

    Cristea, Paul Dan; Tuduce, Rodica Aurora

    2008-02-01

    Nucleotide genomic signals satisfy regularities that reveal restrictions in the distribution of nucleotides and pairs of nucleotides along DNA sequences. Structurally, a chromosome appears to be more than a plain text, by satisfying symmetry constrains that evoke the rhythm and rhyme in poems. These regularities make it easy to identify exogenous inserts in the genomes of prokaryotes, because such inserts obey different regularities than the background sequence. The paper presents instances of inserts found in the genomes of Bacillus subtilis, Mycobacterium tuberculosis and other prokaryotes. Inserts of exogenous material are frequently accompanied by complementary inserts tending to restore the original constrains.

  9. Quench Module Insert (QMI) and the Diffusion Module Insert (DMI) Furnace Development

    NASA Technical Reports Server (NTRS)

    Crouch, Myscha; Carswell, William; Farmer, Jeff; Rose, Fred; Tidwell, Paul

    2000-01-01

    This paper presents, in viewgraph form, QMI (Quench Module Insert) and DMI (Diffusion Module Insert) furnace development. The topics include: 1) Furnace Module in Rack; 2) Quench Module Insert; 3) QMI in MSL Core; 4) Diffusion Module Insert; 5) QMI; and 6) QMI Development and Testing.

  10. Mars Observer Orbit Insertion Briefing

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Steve Wall is the host of this video entitled, "Return to the Red Planet". Live animation of the Mars Observer orbiting Mars is presented. Steve Wall explains the spacecraft insertion maneuver and also explains the purpose for the Mars Observer launch. Live coverage of the Cape Canaveral launch of the Mars Observer is also presented. Suzanne Dodd, Chief of the Mission Planning team describes the burn start and how the spacecraft will be captured by Mars' gravity. Glenn Cunningham, Mars Observer Project Manager, gives background information on the Mars Observer and describes the organizations behind the Mars Observer Spacecraft, such as the Deep Space Network, the Mission Operation Support Office, Science Investigators, the Flight Engineering Office, Operations Office, and the Ground Data System Office. Dr. William Piotrowski, Acting Director, Solar System Exploration Division, NASA, talks about the purpose of the Mars Pathfinder which is to develop the technology and systems for landing small science packages on Mars. Mr. Roger Gibbs, Former Mars Observer Spacecraft Systems Engineer, tells us how the Mars Observer was built and describes the structural elements on the Mars Observer. The 11-month cruise period for the spacecraft is given by Joseph Beerer, Manager of the Engineering office. The thrust for the Mars Orbit Insertion is described by Ronald Klemetson, Technical Manager, Propulsion Subsystem Jet Propulsion Laboratory (JPL). George Chen, Lead Engineer Attitude and Articulation Subsystem Spacecraft Team, explains the importance of the attitude control engines on the Spacecraft. Marvin Traxler, Manager of Tracking and Data Acquisition, describes how searching for a signal from the Mars Observer works. See NONP-NASA-VT-2000081555 for a continuation of this discussion with Marvin Traxler.

  11. Peripherally Inserted Central Catheters and Hemodialysis Outcomes.

    PubMed

    McGill, Rita L; Ruthazer, Robin; Meyer, Klemens B; Miskulin, Dana C; Weiner, Daniel E

    2016-08-08

    Use of peripherally inserted central catheters has expanded rapidly, but the consequences for patients who eventually require hemodialysis are undefined. Our national, population-based analysis included 33,918 adult Medicare beneficiaries from the US Renal Data System who initiated hemodialysis with central venous catheters as their sole vascular access in 2010 and 2011. We used linked Medicare claims to identify peripherally inserted central catheter exposures and evaluate the associations of peripherally inserted central catheter placement with transition to working arteriovenous fistulas or grafts and patient survival using a Cox model with time-dependent variables. Among 33,918 individuals initiating hemodialysis with a catheter as sole access, 12.6% had received at least one peripherally inserted central catheter. Median follow-up was 404 days (interquartile range, 103-680 days). Among 6487 peripherally inserted central catheters placed, 3435 (53%) were placed within the 2 years before hemodialysis initiation, and 3052 (47%) were placed afterward. Multiple peripherally inserted central catheters were placed in 30% of patients exposed to peripherally inserted central catheters. Recipients of peripherally inserted central catheters were more likely to be women and have comorbid diagnoses and less likely to have received predialysis nephrology care. After adjustment for clinical and demographic factors, peripherally inserted central catheters placed before or after hemodialysis initiation were independently associated with lower likelihoods of transition to any working fistula or graft (hazard ratio for prehemodialysis peripherally inserted central catheter, 0.85; 95% confidence interval, 0.79 to 0.91; hazard ratio for posthemodialysis peripherally inserted central catheter, 0.81; 95% confidence interval, 0.73 to 0.89). Peripherally inserted central catheter placement was common and associated with adverse vascular access outcomes. Recognition of potential long

  12. Sequential cooling insert for turbine stator vane

    DOEpatents

    Jones, Russel B

    2017-04-04

    A sequential flow cooling insert for a turbine stator vane of a small gas turbine engine, where the impingement cooling insert is formed as a single piece from a metal additive manufacturing process such as 3D metal printing, and where the insert includes a plurality of rows of radial extending impingement cooling air holes alternating with rows of radial extending return air holes on a pressure side wall, and where the insert includes a plurality of rows of chordwise extending second impingement cooling air holes on a suction side wall. The insert includes alternating rows of radial extending cooling air supply channels and return air channels that form a series of impingement cooling on the pressure side followed by the suction side of the insert.

  13. Insertion devices at the advanced photon source

    SciTech Connect

    Moog, E.R.

    1996-07-01

    The insertion devices being installed at the Advanced Photon Source cause the stored particle beam to wiggle, emitting x-rays with each wiggle. These x-rays combine to make an intense beam of radiation. Both wiggler and undulator types of insertion devices are being installed; the characteristics of the radiation produced by these two types of insertion devices are discussed, along with the reasons for those characteristics.

  14. Nozzle insert for mixed mode fuel injector

    DOEpatents

    Lawrence, Keith E.

    2006-11-21

    A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set controlled respectively, by first and second needle valve members. The homogeneous charged nozzle outlet set is defined by a nozzle insert that is attached to an injector body, which defines the conventional nozzle outlet set. The nozzle insert is a one piece metallic component with a large diameter segment separated from a small diameter segment by an annular engagement surface. One of the needle valve members is guided on an outer surface of the nozzle insert, and the nozzle insert has an interference fit attachment to the injector body.

  15. Properties of a symmetric RHIC insertion

    SciTech Connect

    Lee, S.Y.

    1991-07-01

    This report evaluates the lattice functions of the symmetric insertion proposed by A.G. Ruggiero for the RHIC insertion. The crossing geometry, Inner and Outer matching sections, and chromatic properties are studied in detail. Some properties of the missing dipole dispersion correction scheme are also discussed. We found that the chromatic properties of the symmetric insertion is not better than the antisymmetric insertion. The problem is that the four family sextupole correction scheme seems not able to improve the chromatic distortion. Analytic understanding of the failure of the four family sextupole correction scheme will be very useful. 9 figs., 1 tab.

  16. Automatic Steering of Manually Inserted Needles

    PubMed Central

    Wu, Guofan; Li, Xiao; Lehocky, Craig A.; Riviere, Cameron N.

    2014-01-01

    Bevel-tipped flexible needles can be robotically steered to reach clinical targets along curvilinear paths in 3D. Manual needle insertion allows the clinician to control the insertion speed, ensuring patient safety. This paper presents a control law for automatic 3D steering of manually inserted flexible needles, enabling path-following control. A look-ahead proportional controller for position and orientation is presented. The look-ahead distance is a linear function of insertion speed. Simulations in a 3D brain-like environment demonstrate the performance of the proposed controller. Experimental results also show the feasibility of this technique in 2D and 3D environments. PMID:24752485

  17. Pericarditis following permanent pacemaker insertion.

    PubMed

    Levy, Yair; Shovman, Ora; Granit, Chava; Luria, David; Gurevitz, Osnat; Bar-Lev, David; Eldar, Michael; Shoenfeld, Yehuda; Glikson, Michael

    2004-10-01

    The appearance of pericarditis following insertion of a permanent pacemaker is not widely acknowledged in the literature. To describe our experience with pericarditis following 395 permanent pacemaker implantations over 2 years. We retrospectively reviewed the medical records of 395 consecutive patients in whom new pacing systems or pacemaker leads had been implanted over a 2 year period. We searched the records for pericarditis that developed within 1 month after pacemaker implantation according to the ICD-9 code. The incidence, clinical picture, response to treatment, and relationship to lead design and location were studied. Eight cases (2%) of pericarditis following implantation were detected. Clinical manifestations in all patients were similar to those of post-pericardiotomy syndrome and included chest pain (n = 7), friction rub (n = 1), fever (n = 2), fatigue (n = 2), pleural effusion (n = 2), new atrial fibrillation (n = 2), elevated erythrocyte sedimentation rate (n = 4), and echcardiographic evidence of pericardial effusion (n = 8). All affected patients had undergone active fixation (screw-in) lead implantation in the atrial position. The incidence of pericarditis with screw-in atrial leads was 3% compared to 0% in other cases (P < 0.05). Pericarditis is not uncommon following pacemaker implantation with active fixation atrial leads. Special attention should be paid to identifying pericardial complications following pacemaker implantation, especially when anticoagulant therapy is resumed or initiated. The use of passive fixation leads is likely to reduce the incidence of pericarditis but this issue should be further investigated.

  18. Multipurpose Transposon-Insertion Libraries in Yeast.

    PubMed

    Kumar, Anuj

    2016-06-01

    Libraries of transposon-insertion alleles constitute powerful and versatile tools for large-scale analysis of yeast gene function. Transposon-insertion libraries are constructed most simply through mutagenesis of a plasmid-based genomic DNA library; modification of the mutagenizing transposon by incorporation of yeast selectable markers, recombination sites, and an epitope tag enables the application of insertion alleles for phenotypic screening and protein localization. In particular, yeast genomic DNA libraries have been mutagenized with modified bacterial transposons carrying the URA3 marker, lox recombination sites, and sequence encoding multiple copies of the hemagglutinin (HA) epitope. Mutagenesis with these transposons has yielded a large resource of insertion alleles affecting nearly 4000 yeast genes in total. Through well-established protocols, these insertion libraries can be introduced into the desired strain backgrounds and the resulting insertional mutants can be screened or systematically analyzed. Relative to alternative methods of UV irradiation or chemical mutagenesis, transposon-insertion alleles can be easily identified by PCR-based approaches or high-throughput sequencing. Transposon-insertion libraries also provide a cost-effective alternative to targeted deletion approaches, although, in contrast to start-codon to stop-codon deletions, insertion alleles might not represent true null-mutants. For protein-localization studies, transposon-insertion alleles can provide encoded epitope tags in-frame with internal codons; in many cases, these transposon-encoded epitope tags can provide a more accurate localization for proteins in which terminal sequences are crucial for intracellular targeting. Thus, overall, transposon-insertion libraries can be used quickly and economically and have a particular utility in screening for desired phenotypes and localization patterns in nonstandard genetic backgrounds. © 2016 Cold Spring Harbor Laboratory Press.

  19. Clinical use of an insert earphone.

    PubMed

    Clemis, J D; Ballad, W J; Killion, M C

    1986-01-01

    There are several applications of and advantages to using an insert earphone. An insert earphone has three parts: a transducer to convert electrical energy to sound, a conduit to deliver the sound into the ear canal, and a coupler connecting the device to the canal. The data from this study indicate that there is a distinct advantage in using insert earphones over TDH-49 phones (standard headphones) in the attenuation of low frequency ambient noise. The use of insert earphones will permit one to test hearing in areas of higher ambient noise than was previously possible. Insert earphones are used to shorten the hearing aid selection process. A technique is described in which only one real ear measurement is required for an accurate hearing aid fitting. Most, but not all, of the masking dilemmas that are encountered with standard headphones are circumvented or eliminated by using insert earphones. In brain stem auditory evoked response testing, the insert earphone reduces the stimulus artifact without influencing the acoustic signal. Finally, the insert earphone solves the collapsing ear canal problem.

  20. Turbine vane segment and impingement insert configuration for fail-safe impingement insert retention

    DOEpatents

    Burdgick, Steven Sebastian; Kellock, Iain Robertson

    2003-05-13

    An impingement insert sleeve is provided that is adapted to be disposed in a coolant cavity defined through a stator vane. The insert has a generally open inlet end and first and second pairs of diametrically opposed side walls, and at least one fail-safe tab defined at a longitudinal end of the insert for limiting radial displacement of the insert with respect to the stator vane.

  1. Intradermal normal saline solution, self-selected music, and insertion difficulty effects on intravenous insertion pain.

    PubMed

    Jacobson, A F

    1999-01-01

    To examine the effect of listening to self-selected music versus an intradermal injection of normal saline solution on the intensity and distress of intravenous (IV) catheter insertion pain. Prospective, randomized, controlled study. Inpatient and outpatient units in 2 university-affiliated southwestern medical centers. One hundred ten adult inpatients and outpatients undergoing IV therapy. Pain intensity, pain distress, and IV insertion difficulty visual analog scales. Patients were randomly assigned to receive an intradermal injection of normal saline solution, listen with headphones to self-selected music, or be in a control group for IV insertion. A MANOVA revealed no statistically significant multivariate or univariate differences in pain by treatment group, but significantly higher pain distress scores with failed IV insertions. The pain intensity and distress scores were significantly higher in the saline solution group when compared with the music and control groups combined. Insertion difficulty was significantly positively correlated with pain intensity and distress for the entire sample, with weak, nonsignificant correlations in the music group. Intradermal unpreserved saline solution contributes to greater pain intensity and distress, greater insertion difficulty, and a higher failure rate than the use of music or routine IV insertion. Listening to preferred music attenuates the effect of insertion difficulty on IV insertion pain. Intravenous insertion attempts were unsuccessful in more than one third of the subjects, resulting in higher pain distress scores. Further research is needed on interventions to reduce IV insertion pain and on factors contributing to IV insertion failure.

  2. Central Solenoid Insert Technical Specification

    SciTech Connect

    Martovetsky, Nicolai N; Smirnov, Alexandre

    2011-09-01

    The US ITER Project Office (USIPO) is responsible for the ITER central solenoid (CS) contribution to the ITER project. The Central Solenoid Insert (CSI) project will allow ITER validation the appropriate lengths of the conductors to be used in the full-scale CS coils under relevant conditions. The ITER Program plans to build and test a CSI to verify the performance of the CS conductor. The CSI is a one-layer solenoid with an inner diameter of 1.48 m and a height of 4.45 m between electric terminal ends. The coil weight with the terminals is approximately 820 kg without insulation. The major goal of the CSI is to measure the temperature margin of the CS under the ITER direct current (DC) operating conditions, including determining sensitivity to load cycles. Performance of the joints, ramp rate sensitivity, and stability against thermal or electromagnetic disturbances, electrical insulation, losses, and instrumentation are addressed separately and therefore are not major goals in this project. However, losses and joint performance will be tested during the CSI testing campaign. The USIPO will build the CSI that will be tested at the Central Solenoid Model Coil (CSMC) Test Facility at the Japan Atomic Energy Agency (JAEA), Naka, Japan. The industrial vendors (the Suppliers) will report to the USIPO (the Company). All approvals to proceed will be issued by the Company, which in some cases, as specified in this document, will also require the approval of the ITER Organization. Responsibilities and obligations will be covered by respective contracts between the USIPO, called Company interchangeably, and the industrial Prime Contractors, called Suppliers. Different stages of work may be performed by more than one Prime Contractor, as described in this specification. Technical requirements of the contract between the Company and the Prime Contractor will be covered by the Fabrication Specifications developed by the Prime Contractor based on this document and approved by

  3. IUD insertion immediately after incomplete abortion.

    PubMed

    Goldsmith, A; Goldberg, R; Eyzaguirre, H; Lizana, L

    1972-04-01

    All women who were admitted to the Felix Bulnes Hospital, Santiaog, Chile, for incomplete abortion between July 1968 and June 1969 were given instruction in family planning and contraceptive services. A total of 584 women chose to have an IUD insertion. Although all the women thought they had received an IUD, 1 group had a Lippes loop D inserted immediately after curettage and the other group had no insertion. The attending doctor had no prior knowledge as to which women were to receive the device nor did the doctor at the follow-up know until after the physical exam had taken place. 30 days after discharge from the hospital, the women returned from check-up and follow-up. At this time the women who had not received an IUD were given an insertion. Differences between the group with insertion and the one without were significant only for the interval between curettage and first menses and for the quantity of flow in relation to previous menstruation. The difference between the 2 groups for duration of menstrual flow was of borderline significance at the .05 significance level. It is concluded from the study that in the absence of psychologi cal bias of the patient to the IUD insertion, and possibly bias in its use by the doctor, there are no serious complications in the first month following immediate postabortal IUD insertion even where the abortion was a septic incomplete one.

  4. Insertion sequence elements in Lactococcus garvieae.

    PubMed

    Eraclio, Giovanni; Ricci, Giovanni; Fortina, Maria Grazia

    2015-01-25

    Insertion sequences are the simplest intracellular Mobile Genetic Elements which can occur in very high numbers in prokaryotic genomes, where they play an important evolutionary role by promoting genome plasticity. As such, the studies on the diversity and distribution of insertion sequences in genomes not yet investigated can contribute to improve the knowledge on a bacterial species and to identify new transposable elements. The present work describes the occurrence of insertion sequences in Lactococcus garvieae, an opportunistic emerging zoonotic and human pathogen, also associated with different food matrices. To date, no insertion elements have been described for L. garvieae in the IS element database. The analysis of the twelve published L. garvieae genomes identified 15 distinct insertion sequences that are members of the IS3, IS982, IS6, IS21 and IS256 families, including five new elements. Most of the insertion sequences in L. garvieae show substantial homology to the Lactococcus lactis elements, suggesting the movement of IS between these two species phylogenetically closely related. ISLL6 elements belonging to IS3 family were most abundant, with several copies distributed in 9 of the 12 genomes analyzed. An alignment analysis of two complete genomes carrying multi-copies of this insertion sequence indicates a possible involvement of ISLL6 in chromosomal rearrangement.

  5. Assessment of heat generation during implant insertion.

    PubMed

    Sumer, Mahmut; Keskiner, Ilker; Mercan, Ugur; Misir, Ferhat; Cankaya, Soner

    2014-09-01

    Many studies have investigated the heat generated during implant preparation, but data are needed to better predict heat generation during implant insertion. The purpose of this study was to measure the heat generated during insertion of an implant at speeds of 30, 50, and 100 rpm, and with manual insertion. Sixty-four uniform fresh bovine femoral cortical bone specimens were used. After the cortical bone was drilled, 3 different implant insertion speeds and the manual insertion of the implant were evaluated for 2 different implant diameters. The temperature was measured with 2 Teflon-insulated, type K thermocouples. Data were analyzed by 2-way ANOVA, and the Tukey honestly significant difference test (α=.05). The highest thermal change for 4.1-mm-diameter implants was found at a speed of 100 rpm (9.81°C ±2.29°C), and the lowest thermal change was 3.69°C ±0.85°C at a speed of 30 rpm. A statistically significant difference was found between 100 rpm and the other 3 insertion procedures. The highest thermal change for a 4.8-mm-diameter implant was found at a speed of 100 rpm (8.79°C ±1.53°C), and the lowest thermal change was 4.48°C ±0.85°C at a speed of 30 rpm. No statistical difference was observed with manual, 30 rpm, and 50 rpm; however, a statistically significant difference was found between 100 rpm and the other 3 insertion procedures. Manual implant insertion and at speeds of 30 rpm and 50 rpm generated lower heat compared with insertion at 100 rpm. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Sequential cooling insert for turbine stator vane

    SciTech Connect

    Jones, Russell B; Krueger, Judson J; Plank, William L

    2014-04-01

    A sequential impingement cooling insert for a turbine stator vane that forms a double impingement for the pressure and suction sides of the vane or a triple impingement. The insert is formed from a sheet metal formed in a zigzag shape that forms a series of alternating impingement cooling channels with return air channels, where pressure side and suction side impingement cooling plates are secured over the zigzag shaped main piece. Another embodiment includes the insert formed from one or two blocks of material in which the impingement channels and return air channels are machined into each block.

  7. Sequential cooling insert for turbine stator vane

    SciTech Connect

    Jones, Russel B; Krueger, Judson J; Plank, William L

    2014-11-04

    A sequential impingement cooling insert for a turbine stator vane that forms a double impingement for the pressure and suction sides of the vane or a triple impingement. The insert is formed from a sheet metal formed in a zigzag shape that forms a series of alternating impingement cooling channels with return air channels, where pressure side and suction side impingement cooling plates are secured over the zigzag shaped main piece. Another embodiment includes the insert formed from one or two blocks of material in which the impingement channels and return air channels are machined into each block.

  8. Elliptically polarizing adjustable phase insertion device

    DOEpatents

    Carr, Roger

    1995-01-01

    An insertion device for extracting polarized electromagnetic energy from a beam of particles is disclosed. The insertion device includes four linear arrays of magnets which are aligned with the particle beam. The magnetic field strength to which the particles are subjected is adjusted by altering the relative alignment of the arrays in a direction parallel to that of the particle beam. Both the energy and polarization of the extracted energy may be varied by moving the relevant arrays parallel to the beam direction. The present invention requires a substantially simpler and more economical superstructure than insertion devices in which the magnetic field strength is altered by changing the gap between arrays of magnets.

  9. Arthroscopic classification of posterior labrum glenoid insertion.

    PubMed

    Nourissat, G; Radier, C; Aim, F; Lacoste, S

    2014-04-01

    We performed a prospective arthroscopic study to explore the variability of the posterior labrum glenoid insertion. We aimed to classify the insertions and to explore whether these insertions can be identified by pre-operative arthro-CT scan. From January to December 2011, 86 patients were prospectively included in the current study. During arthroscopy, anterior labrum was evaluated and posterior labrum was assessed in 3 different locations: superior, medial, and inferior. For each segment, the labrum was considered normally inserted (directly to the glenoid cartilage), medialized (inserted at the posterior part of the glenoid bone, without direct contact with the cartilage), torn (macroscopic degenerative changes, tears, fragments) or absent (agenesis). Imaging was analyzed segment by segment by an experienced osteoarticular radiologist, using the same classification. Four types of posterior labrum insertions were identified. Type 1, 60% of the cases, corresponded to a posterior labrum totally inserted in the glenoid, with direct contact with the cartilage. Type 2, 20% of the cases, represented medialized insertion of the superior segment. Type 3, 15% of the cases, represented an associated medialization of the superior and medial segment of the posterior labrum. Type 4 is a medialized insertion of the all-posterior labrum. Fifty-six shoulders were used for arthro-CT and arthroscopy correlation: for the superior segment (n=22/56), the sensitivity of arthro-CT to identify an abnormal insertion when the labrum is medialized was 68.18%, specificity 70.59%, positive predictive value (PPV) 60%, and negative predictive value (NPV) 77.42%. For the medial segment (n=16/56), the sensitivity of arthro-CT to identify an abnormal insertion when the labrum is medialized was 81.25%, specificity 57.50%, PPV 43.33% and NPV 88.46%. For the inferior segment (n=5/56), the sensitivity was 100%, specificity 47.60%, PPV 15.63% and NPV 100%. The current study points out the high

  10. Insertion Profiles of 4 Headless Compression Screws

    PubMed Central

    Hart, Adam; Harvey, Edward J.; Lefebvre, Louis-Philippe; Barthelat, Francois; Rabiei, Reza; Martineau, Paul A.

    2013-01-01

    Purpose In practice, the surgeon must rely on screw position (insertion depth) and tactile feedback from the screwdriver (insertion torque) to gauge compression. In this study, we identified the relationship between interfragmentary compression and these 2 factors. Methods The Acutrak Standard, Acutrak Mini, Synthes 3.0, and Herbert-Whipple implants were tested using a polyurethane foam scaphoid model. A specialized testing jig simultaneously measured compression force, insertion torque, and insertion depth at half-screw-turn intervals until failure occurred. Results The peak compression occurs at an insertion depth of −3.1 mm, −2.8 mm, 0.9 mm, and 1.5 mm for the Acutrak Mini, Acutrak Standard, Herbert-Whipple, and Synthes screws respectively (insertion depth is positive when the screw is proud above the bone and negative when buried). The compression and insertion torque at a depth of −2 mm were found to be 113 ± 18 N and 0.348 ± 0.052 Nm for the Acutrak Standard, 104 ± 15 N and 0.175 ± 0.008 Nm for the Acutrak Mini, 78 ± 9 N and 0.245 ± 0.006 Nm for the Herbert-Whipple, and 67 ± 2N, 0.233 ± 0.010 Nm for the Synthes headless compression screws. Conclusions All 4 screws generated a sizable amount of compression (> 60 N) over a wide range of insertion depths. The compression at the commonly recommended insertion depth of −2 mm was not significantly different between screws; thus, implant selection should not be based on compression profile alone. Conically shaped screws (Acutrak) generated their peak compression when they were fully buried in the foam whereas the shanked screws (Synthes and Herbert-Whipple) reached peak compression before they were fully inserted. Because insertion torque correlated poorly with compression, surgeons should avoid using tactile judgment of torque as a proxy for compression. Clinical relevance Knowledge of the insertion profile may improve our understanding of the implants, provide a better basis for comparing screws

  11. Insertable fluid flow passage bridgepiece and method

    DOEpatents

    Jones, Daniel O.

    2000-01-01

    A fluid flow passage bridgepiece for insertion into an open-face fluid flow channel of a fluid flow plate is provided. The bridgepiece provides a sealed passage from a columnar fluid flow manifold to the flow channel, thereby preventing undesirable leakage into and out of the columnar fluid flow manifold. When deployed in the various fluid flow plates that are used in a Proton Exchange Membrane (PEM) fuel cell, bridgepieces of this invention prevent mixing of reactant gases, leakage of coolant or humidification water, and occlusion of the fluid flow channel by gasket material. The invention also provides a fluid flow plate assembly including an insertable bridgepiece, a fluid flow plate adapted for use with an insertable bridgepiece, and a method of manufacturing a fluid flow plate with an insertable fluid flow passage bridgepiece.

  12. Utility Bill Insert for Wastewater Services

    EPA Pesticide Factsheets

    Intended for use by wastewater and water supply utilities, one side of the utility bill insert has information for customers that discharge to sanitary sewer systems; the other side is for customers with septic systems.

  13. Bulkhead insert for an internal combustion engine

    DOEpatents

    Maki, Clifford E.; Chottiner, Jeffrey Eliot; Williams, Rick L.; Thibault, Mark W.; Ervin, James Douglas; Boileau, James Maurice; McKeough, Bryan

    2017-08-01

    An engine includes a cylinder block defining at least one main bearing bulkhead adjacent to a cylinder, and a crankshaft rotatably housed within the block by a main bearing. A bulkhead insert has a cap portion, and an insert portion provided within the bulkhead. The insert portion has having first and second end regions connected by first and second straps. Each strap having a flanged beam cross section. The first and second ends of the insert portion are configured to connect a main bearing cap column to a cylinder head column. Each of the first and second end regions define at least one protrusion having a surface substantially normal to engine combustion and reactive loads. The cap portion is configured to mate with the first end region at the main bearing cap column and support the main bearing.

  14. Clinical applicability of insert earphones for audiometry.

    PubMed

    Borton, T E; Nolen, B L; Luks, S B; Meline, N C

    1989-01-01

    Insert transducers for audiometry are available which may offer significant advantages over older 'standard' headphones. Clinicians have remained cautious in using such devices due to the paucity of experimental data demonstrating their comparability with more widely used devices. The purpose of this investigation was to compare and contrast pure-tone audiometric thresholds obtained using insert earphones with those measured utilizing conventional supra-aural transducers in normal and hearing-impaired subjects. A second purpose was to examine the differential effects on the hearing threshold level of two coupling systems for the insert device. There were no clinically significant differences among pure-tone thresholds measured with the three earphone/coupler arrangements for subjects with normal and impaired hearing. Advantages and limitations of insert earphones are discussed.

  15. The effects of insertion method and force on hand clearance envelopes for rubber hose insertion tasks.

    PubMed

    Grieshaber, D Christian; Armstrong, Thomas J; Chaffin, Don B; Keyserling, W Monroe; Ashton-Miller, James

    2009-04-01

    The aim of this study was to determine how hand space for manual insertion of flexible hoses is affected by insertion method and force. Adequate space is needed during assembly tasks in which workers join parts together with their hands. Hose installations are an example of such a task. Hand clearance envelopes for insertion tasks that involve cylindrical objects, such as a hose, are currently unavailable in the literature. Participants inserted a flexible 25-mm rubber hose onto a stationary flange using simulated methods similar to those observed in field studies of automotive assembly tasks. Markers placed on the back of the hand and wrists were used to measure postures during the insertion task. Hand clearance envelopes for high-force insertions were significantly larger across methods by an average of 15% for both male (p < .05) and female (p < .01) participants. Rocking insertions resulted in the largest hand clearance envelopes compared with other insertion methods. Rocking and twisting the hose resulted in mean increases in the cross-sectional area of the hand clearance envelopes of 35% and 24%, respectively, compared with the straight push. Differences were significant (p < .05) for male and female participants for both bead height conditions. Both required insertion force and method affect hand clearance envelopes during simulated insertions. These methods can be used by engineers to determine if there is adequate clearance for the hand to grip selected objects.

  16. Shrink-Fit Solderable Inserts Seal Hermetically

    NASA Technical Reports Server (NTRS)

    Croucher, William C.

    1992-01-01

    Shrink-fit stainless-steel insert in aluminum equipment housing allows electrical connectors to be replaced by soldering, without degrading hermeticity of housing or connector. Welding could destroy electrostatic-sensitive components and harm housing and internal cables. Steel insert avoids problems because connector soldered directly to it rather than welded to housing. Seals between flange and housing, and between connector and flange resistant to leaks, even after mechanical overloading and thermal shocking.

  17. Efficient instruction sequencing with Inline Target Insertion

    NASA Technical Reports Server (NTRS)

    Hwu, Wen-Mei W.; Chang, Pohua P.

    1992-01-01

    Inline target insertion, a specific compiler and pipeline implementation method for delayed branches with squashing, is defined. The method is shown to offer two important features not discovered in previous studies. First, branches inserted into branch slots are correctly executed. Second, the execution returns correctly from interrupts or exceptions with only one program counter. These two features result in better performance and less software/hardware complexity than conventional delayed branching mechanisms.

  18. Small Unit Space Transport and Insertion (SUSTAIN)

    DTIC Science & Technology

    2009-01-01

    Small Unit Space Transport and Insertion ( SUSTAIN ) Study prepared for: LTC Paul E. Damphousse, USMC National Security Space Office Chief of...failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE 2009 2. REPORT TYPE N/A...3. DATES COVERED - 4. TITLE AND SUBTITLE Small Unit Space Transport and Insertion ( SUSTAIN ) 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM

  19. Insert earphones for speech recognition testing.

    PubMed

    Martin, F N; Severance, G K; Thibodeau, L

    1991-01-01

    Performance-intensity functions for PB word lists were run on 19 normal-hearing subjects and 15 subjects with sensorineural hearing losses. Comparisons were made between standard supra-aural earphones (TDH-49P) and insert phones (ER-3A). Results showed that, at least for the higher sensation levels where word recognition tests are usually performed, the phones may be used interchangeably. Using insert earphones for word recognition tests can have several beneficial effects with respect to cross hearing and masking.

  20. Shrink-Fit Solderable Inserts Seal Hermetically

    NASA Technical Reports Server (NTRS)

    Croucher, William C.

    1992-01-01

    Shrink-fit stainless-steel insert in aluminum equipment housing allows electrical connectors to be replaced by soldering, without degrading hermeticity of housing or connector. Welding could destroy electrostatic-sensitive components and harm housing and internal cables. Steel insert avoids problems because connector soldered directly to it rather than welded to housing. Seals between flange and housing, and between connector and flange resistant to leaks, even after mechanical overloading and thermal shocking.

  1. Strength of inserts in titanium alloy machining

    NASA Astrophysics Data System (ADS)

    Kozlov, V.; Huang, Z.; Zhang, J.

    2016-04-01

    In this paper, a stressed state of a non-worn cutting wedge in a machined titanium alloy (Ti6Al2Mo2Cr) is analyzed. The distribution of contact loads on the face of a cutting tool was obtained experimentally with the use of a ‘split cutting tool’. Calculation of internal stresses in the indexable insert made from cemented carbide (WC8Co) was carried out with the help of ANSYS 14.0 software. Investigations showed that a small thickness of the cutting insert leads to extremely high compressive stresses near the cutting edge, stresses that exceed the ultimate compressive strength of cemented carbide. The face and the base of the insert experience high tensile stresses, which approach the ultimate tensile strength of cemented carbide and increase a probability of cutting insert destruction. If the thickness of the cutting insert is bigger than 5 mm, compressive stresses near the cutting edge decrease, and tensile stresses on the face and base decrease to zero. The dependences of the greatest normal and tangential stresses on thickness of the cutting insert were found. Abbreviation and symbols: m/s - meter per second (cutting speed v); mm/r - millimeter per revolution (feed rate f); MPa - mega Pascal (dimension of specific contact loads and stresses); γ - rake angle of the cutting tool [°] α - clearance angle of the sharp cutting tool [°].

  2. Z-2 Threaded Insert Design and Testing

    NASA Technical Reports Server (NTRS)

    Ross, Amy; Rhodes, Richard; Jones, Robert J.; Graziosi, David; Ferl, Jinny; Sweeny, Mitch; Scarborough, Stephen

    2016-01-01

    NASA's Z-2 prototype space suit contains several components fabricated from an advanced hybrid composite laminate consisting of IM10 carbon fiber and fiber glass. One requirement was to have removable, replaceable helicoil inserts to which other suit components would be fastened. An approach utilizing bonded in inserts with helicoils inside of them was implemented. During initial assembly, cracking sounds were heard followed by the lifting of one of the blind inserts out of its hole when the screws were torqued. A failure investigation was initiated to understand the mechanism of the failure. Ultimately, it was determined that the pre-tension caused by torqueing the fasteners is a much larger force than induced from the pressure loads of the suit which was not considered in the insert design. Bolt tension is determined by dividing the torque on the screw by a k value multiplied by the thread diameter of the bolt. The k value is a factor that accounts for friction in the system. A common value used for k for a non-lubricated screw is 0.2. The k value can go down by as much as 0.1 if the screw is lubricated which means for the same torque, a much larger tension could be placed on the bolt and insert. This paper summarizes the failure investigation that was performed to identify the root cause of the suit failure and details how the insert design was modified to resist a higher pull out tension.

  3. High-Pressure Trocar Insertion Technique

    PubMed Central

    Reich, Harry; Conti Ribeiro, Sergio; Rasmussen, Carsten; Rosenberg, Jay

    1999-01-01

    Background: The majority of laparoscopic complications occur at the time of Veress needle and trocar insertion. Although not very frequent, they increase the morbidity and mortality of both diagnostic and operative laparoscopic procedures. Alternative techniques of trocar insertion have been described but have not completely eliminated the risk of injury. Technique: After Veress needle insertion and establishment of pneumoperitoneum to 25 to 30 mm Hg, insertion of a short trocar is performed in the deepest part of the umbilicus without elevation of the anterior abdominal wall. The result is a parietal peritoneal puncture directly beneath the umbilicus. The high-pressure setting used during initial insertion of the trocar is lowered as soon as safe abdominal entry is documented. Experience: The trocar insertion technique described above was performed in 3041 procedures. No vascular injury occurred. There were two bowel perforations. No complications related to the increased intra-abdominal pressure were observed. Conclusion: The high-pressure abdominal entry technique has the advantage of reducing intra-abdominal trocar-related injuries without requiring additional instrumentation or additional training. PMID:10323169

  4. Rectal suppository: commonsense and mode of insertion.

    PubMed

    Abd-el-Maeboud, K H; el-Naggar, T; el-Hawi, E M; Mahmoud, S A; Abd-el-Hay, S

    1991-09-28

    Rectal suppository is a well-known form of medication and its use is increasing. The commonest shape is one with an apex (pointed end) tapering to a base (blunt end). Because of a general lack of information about mode of insertion, we asked 360 lay subjects (Egyptians and non-Egyptians) and 260 medical personnel (physicians, pharmacists, and nurses) by questionnaire which end they inserted foremost. Apart from 2 individuals, all subjects suggested insertion with the apex foremost. Commonsense was the most frequent basis for this practice (86.9% of lay subjects and 84.6% of medical personnel) followed by information from a relative, a friend, or medical personnel, or from study at medical school. Suppository insertion with the base or apex foremost was compared in 100 subjects (60 adults, 40 infants and children). Retention with the former method was more easily achieved in 98% of the cases, with no need to introduce a finger in the anal canal (1% vs 83%), and lower expulsion rate (0% vs 3%). The designer of the "torpedo-shaped" suppository suggested its insertion with apex foremost. Our data suggest that a suppository is better inserted with the base foremost. Reversed vermicular contractions or pressure gradient of the anal canal might press it inwards.

  5. The Pixel Detector of the ATLAS Experiment for the Run 2 at the Large Hadron Collider

    NASA Astrophysics Data System (ADS)

    Mandelli, B.; ATLAS Collaboration

    2016-04-01

    The Pixel Detector of the ATLAS experiment has shown excellent performance during the whole Run 1 of LHC. Taking advantage of the long shutdown, the detector was extracted from the experiment and brought to surface, to equip it with new service quarter panels, to repair modules and to ease installation of the Insertable B-Layer (IBL). The IBL is a fourth layer of pixel detectors, and has been installed in May 2014 between the existing Pixel Detector and a new smaller radius beam-pipe. To cope with the high radiation and pixel occupancy due to the proximity to the interaction point, a new read-out chip and two different silicon sensor technologies (planar and 3D) have been developed. Furthermore, the physics performance will be improved through the reduction of the pixel size while, targeting for a low material budget, a new mechanical support using lightweight staves and a CO2 based cooling system have been adopted. The IBL construction and installation in the ATLAS experiment has been completed very successfully. The IBL qualification has shown outstanding detector performance with less then 0.09% of bad pixels. The final commissioning is now on-going and the ATLAS Pixel Detector is ready to join the LHC Run 2 with an improved configuration and a new pixel layer.

  6. The upgraded Pixel Detector of the ATLAS Experiment for Run 2 at the Large Hadron Collider

    NASA Astrophysics Data System (ADS)

    Backhaus, M.

    2016-09-01

    During Run 1 of the Large Hadron Collider (LHC), the ATLAS Pixel Detector has shown excellent performance. The ATLAS collaboration took advantage of the first long shutdown of the LHC during 2013 and 2014 and extracted the ATLAS Pixel Detector from the experiment, brought it to surface and maintained the services. This included the installation of new service quarter panels, the repair of cables, and the installation of the new Diamond Beam Monitor (DBM). Additionally, a completely new innermost pixel detector layer, the Insertable B-Layer (IBL), was constructed and installed in May 2014 between a new smaller beam pipe and the existing Pixel Detector. With a radius of 3.3 cm the IBL is located extremely close to the interaction point. Therefore, a new readout chip and two new sensor technologies (planar and 3D) are used in the IBL. In order to achieve best possible physics performance the material budget was improved with respect to the existing Pixel Detector. This is realized using lightweight staves for mechanical support and a CO2 based cooling system. This paper describes the improvements achieved during the maintenance of the existing Pixel Detector as well as the performance of the IBL during the construction and commissioning phase. Additionally, first results obtained during the LHC Run 2 demonstrating the distinguished tracking performance of the new Four Layer ATLAS Pixel Detector are presented.

  7. Novel time-dependent alignment of the ATLAS Inner Detector in the LHC Run 2

    NASA Astrophysics Data System (ADS)

    Jiménez Peña, J.

    2016-11-01

    ATLAS is a multipurpose experiment at the LHC proton-proton collider. Its physics goals require an unbiased and high resolution measurement of the charged particle kinematic parameters. These critically depend on the layout and performance of the tracking system and the quality of the alignment of its components. For the LHC Run 2, the system has been upgraded with the installation of a new pixel layer, the Insertable B-layer (IBL) . ATLAS Inner Detector alignment framework has been adapted and upgraded to correct very short time scale movements of the sub-detectors. In particular, a mechanical distortion of the IBL staves up to 20 μm and a vertical displacement of the Pixel detector of ~ 6 μm have been observed during data-taking. The techniques used to correct for these effects and to match the required Inner Detector performance will be presented.

  8. Field-free spin-orbit torque switching of composite perpendicular CoFeB/Gd/CoFeB layers utilized for three-terminal magnetic tunnel junctions

    NASA Astrophysics Data System (ADS)

    Chen, Jun-Yang; DC, Mahendra; Zhang, Delin; Zhao, Zhengyang; Li, Mo; Wang, Jian-Ping

    2017-07-01

    Spin-orbit torque (SOT) induced magnetization switching has become a research focus in spintronics because it enables energy-efficient switching. There have been several experiments realizing field-free SOT-induced magnetization switching of materials with perpendicular magnetic anisotropy (PMA) in a bilayer system, either using thin Co(Fe) and CoFeB layers with interfacial PMA or using Co/Ni multilayers. All of these stacks are ferromagnets with large saturation magnetization (MS). Here, we demonstrate SOT switching in a multilayer stack of CoFeB/Gd/CoFeB. This stack shows a good PMA and a low MS (370 ± 20 emu/cm3), where CoFeB and Gd layers are antiferromagnetically exchange-coupled with each other. SOT induced magnetization switching has been demonstrated in this stack at zero magnetic field with a switching current density of ˜9.6 × 106 A/cm2 by using antiferromagnetic PtMn as the spin Hall channel material. The spin Hall angle of PtMn was also determined to be ˜0.084 ± 0.005 by performing a second harmonic Hall measurement. This layer structure is compatible with perpendicular magnetic tunnel junctions (p-MTJs), which could enable field-free three-terminal p-MTJs and lead to memory and logic devices based on SOT.

  9. Intrauterine device insertion during the postpartum period: a systematic review.

    PubMed

    Kapp, Nathalie; Curtis, Kathryn M

    2009-10-01

    Insertion of an intrauterine device (IUD) at different times or by different routes during the postpartum period may increase the risk of complications. We searched Medline, Lilacs and Cochrane Collaboration databases for articles in any language, between database inception until December 2008, which compared outcomes of postpartum IUD insertion time intervals. Search terms included postpartum, puerperium, postcesarean delivery, cesarean section, IUD(s), IUCD(s), intrauterine device(s) and insertion. From 297 articles, we identified 15 for inclusion in this review: all studies examined the outcomes from copper IUD insertions within the postpartum time period compared to other time intervals or compared routes (vaginal or via hysterotomy) of postpartum insertion. No studies of levonorgestrel IUDs were identified. Immediate IUD insertion (within 10 min of placental delivery) was safe when compared with later postpartum time periods and interval insertion. Immediate postpartum IUD insertion demonstrated lower expulsion rates when compared with delayed postpartum insertion but with higher rates than interval insertion. Immediate insertion following cesarean delivery demonstrated lower expulsion rates than immediate insertion following vaginal delivery. Poor to fair quality evidence from 15 articles demonstrated no increase in risk of complications among women who had an IUD inserted during the postpartum period; however, some increase in expulsion rates occurred with delayed postpartum insertion when compared to immediate insertion and with immediate insertion when compared to interval insertion. Postplacental placements during cesarean delivery are associated with lower expulsion rates than postplacental vaginal insertions, without increasing rates of postoperative complications.

  10. Reactivity of methacrylates in insertion polymerization.

    PubMed

    Rünzi, Thomas; Guironnet, Damien; Göttker-Schnetmann, Inigo; Mecking, Stefan

    2010-11-24

    Polymerization of ethylene by complexes [{(P^O)PdMe(L)}] (P^O = κ(2)-(P,O)-2-(2-MeOC(6)H(4))(2)PC(6)H(4)SO(3))) affords homopolyethylene free of any methyl methacrylate (MMA)-derived units, even in the presence of substantial concentrations of MMA. In stoichiometric studies, reactive {(P^O)Pd(Me)L} fragments generated by halide abstraction from [({(P^O)Pd(Me)Cl}μ-Na)(2)] insert MMA in a 1,2- as well as 2,1-mode. The 1,2-insertion product forms a stable five-membered chelate by coordination of the carbonyl group. Thermodynamic parameters for MMA insertion are ΔH(++) = 69.0(3.1) kJ mol(-1) and ΔS(++) = -103(10) J mol(-1) K(-1) (total average for 1,2- and 2,1-insertion), in comparison to ΔH(++) = 48.5(3.0) kJ mol(-1) and ΔS(++) = -138(7) J mol(-1) K(-1) for methyl acrylate (MA) insertion. These data agree with an observed at least 10(2)-fold preference for MA incorporation vs MMA incorporation (not detected) under polymerization conditions. Copolymerization of ethylene with a bifunctional acrylate-methacrylate monomer yields linear polyethylenes with intact methacrylate substituents. Post-polymerization modification of the latter was exemplified by free-radical thiol addition and by cross-metathesis.

  11. Nozzle cavity impingement/area reduction insert

    DOEpatents

    Yu, Yufeng Phillip; Itzel, Gary Michael; Osgood, Sarah Jane

    2002-01-01

    A turbine vane segment is provided that has inner and outer walls spaced from one another, a vane extending between the inner and outer walls and having leading and trailing edges and pressure and suction sides, the vane including discrete leading edge, intermediate, aft and trailing edge cavities between the leading and trailing edges and extending lengthwise of the vane for flowing a cooling medium; and an insert sleeve within at least one of the cavities and spaced from interior wall surfaces thereof. The insert sleeve has an inlet for flowing the cooling medium into the insert sleeve and has impingement holes defined in first and second walls thereof that respectively face the pressure and suction sides of the vane. The impingement holes of at least one of those first and second walls are defined along substantially only a first, upstream portion thereof, whereby the cooling flow is predominantly impingement cooling along a first region of the insert wall corresponding to the first, upstream portion and the cooling flow is predominantly convective cooling along a second region corresponding to a second, downstream portion of the at least one wall of the insert sleeve.

  12. The LORE1 insertion mutant resource.

    PubMed

    Małolepszy, Anna; Mun, Terry; Sandal, Niels; Gupta, Vikas; Dubin, Manu; Urbański, Dorian; Shah, Niraj; Bachmann, Asger; Fukai, Eigo; Hirakawa, Hideki; Tabata, Satoshi; Nadzieja, Marcin; Markmann, Katharina; Su, Junyi; Umehara, Yosuke; Soyano, Takashi; Miyahara, Akira; Sato, Shusei; Hayashi, Makoto; Stougaard, Jens; Andersen, Stig U

    2016-10-01

    Long terminal repeat (LTR) retrotransposons are closely related to retroviruses, and their activities shape eukaryotic genomes. Here, we present a complete Lotus japonicus insertion mutant collection generated by identification of 640 653 new insertion events following de novo activation of the LTR element Lotus retrotransposon 1 (LORE1) (http://lotus.au.dk). Insertion preferences are critical for effective gene targeting, and we exploit our large dataset to analyse LTR element characteristics in this context. We infer the mechanism that generates the consensus palindromes typical of retroviral and LTR retrotransposon insertion sites, identify a short relaxed insertion site motif, and demonstrate selective integration into CHG-hypomethylated genes. These characteristics result in a steep increase in deleterious mutation rate following activation, and allow LORE1 active gene targeting to approach saturation within a population of 134 682 L. japonicus lines. We suggest that saturation mutagenesis using endogenous LTR retrotransposons with germinal activity can be used as a general and cost-efficient strategy for generation of non-transgenic mutant collections for unrestricted use in plant research.

  13. Peptide partitioning properties from direct insertion studies

    SciTech Connect

    Ulmschneider, Martin; Smith, Jeremy C; Ulmschneider, Jakob

    2010-06-01

    Partitioning properties of polypeptides are at the heart of biological membrane phenomena and their precise quantification is vital for ab-initio structure prediction and the accurate simulation of membrane protein folding and function. Recently the cellular translocon machinery has been employed to determine membrane insertion propensities and transfer energetics for a series of polyleucine segments embedded in a carrier sequence. We show here that the insertion propensity, pathway, and transfer energetics into synthetic POPC bilayers can be fully described by direct atomistic peptide partitioning simulations. The insertion probability as a function of peptide length follows two-state Boltzmann statistics, in agreement with the experiments. The simulations expose a systematic offset between translocon-mediated and direct insertion free energies. Compared to the experiment the insertion threshold is shifted toward shorter peptides by 2 leucine residues. The simulations reveal many hitherto unknown atomic-resolution details about the partitioning process and promise to provide a powerful tool for urgently needed calibration of lipid parameters to match experimentally observed peptide transfer energies.

  14. Elliptically polarizing adjustable phase insertion device

    DOEpatents

    Carr, R.

    1995-01-17

    An insertion device for extracting polarized electromagnetic energy from a beam of particles is disclosed. The insertion device includes four linear arrays of magnets which are aligned with the particle beam. The magnetic field strength to which the particles are subjected is adjusted by altering the relative alignment of the arrays in a direction parallel to that of the particle beam. Both the energy and polarization of the extracted energy may be varied by moving the relevant arrays parallel to the beam direction. The present invention requires a substantially simpler and more economical superstructure than insertion devices in which the magnetic field strength is altered by changing the gap between arrays of magnets. 3 figures.

  15. Interactive simulation of needle insertion models.

    PubMed

    DiMaio, Simon P; Salcudean, Septimiu E

    2005-07-01

    A novel interactive virtual needle insertion simulation is presented. The simulation models are based on measured planar tissue deformations and needle insertion forces. Since the force-displacement relationship is only of interest along the needle shaft, a condensation technique is shown to reduce the computational complexity of linear simulation models significantly. As the needle penetrates or is withdrawn from the tissue model, the boundary conditions that determine the tissue and needle motion change. Boundary condition and local material coordinate changes are facilitated by fast low-rank matrix updates. A large-strain elastic needle model is coupled to the tissue models to account for needle deflection and bending during simulated insertion. A haptic environment, based on these novel interactive simulation techniques, allows users to manipulate a three-degree-of-freedom virtual needle as it penetrates virtual tissue models, while experiencing steering torques and lateral needle forces through a planar haptic interface.

  16. Rack Insertion End Effector (RIEE) automation

    NASA Technical Reports Server (NTRS)

    Malladi, Narasimha

    1993-01-01

    NASA is developing a mechanism to manipulate and insert Racks into the Space Station Logistic modules. The mechanism consists of the following: a base with three motorized degrees of freedom, a 3 section motorized boom that goes from 15 to 44 feet in length, and a Rack Insertion End Effector (RIEE) with 5 hand wheels for precise alignment. The robotics section was tasked with the automation of the RIEE unit. In this report, for the automation of the RIEE unit, application of the Perceptics Vision System was conceptually developed to determine the position and orientation of the RIEE relative to the logistic module, and a MathCad program is written to display the needed displacements for precise alignment and final insertion of the Rack. The uniqueness of this report is that the whole report is in fact a MathCad program including text, derivations, and executable equations with example inputs and outputs.

  17. Mosaic retroposon insertion patterns in placental mammals

    PubMed Central

    Churakov, Gennady; Kriegs, Jan Ole; Baertsch, Robert; Zemann, Anja; Brosius, Jürgen; Schmitz, Jürgen

    2009-01-01

    One and a half centuries after Charles Darwin and Alfred Russel Wallace outlined our current understanding of evolution, a new scientific era is dawning that enables direct observations of genetic variation. However, pure sequence-based molecular attempts to resolve the basal origin of placental mammals have so far resulted only in apparently conflicting hypotheses. By contrast, in the mammalian genomes where they were highly active, the insertion of retroelements and their comparative insertion patterns constitute a neutral, virtually homoplasy-free archive of evolutionary histories. The “presence” of a retroelement at an orthologous genomic position in two species indicates their common ancestry in contrast to its “absence” in more distant species. To resolve the placental origin controversy we extracted ∼2 million potentially phylogenetically informative, retroposon-containing loci from representatives of the major placental mammalian lineages and found highly significant evidence challenging all current single hypotheses of their basal origin. The Exafroplacentalia hypothesis (Afrotheria as the sister group to all remaining placentals) is significantly supported by five retroposon insertions, the Epitheria hypothesis (Xenarthra as the sister group to all remaining placentals) by nine insertion patterns, and the Atlantogenata hypothesis (a monophyletic clade comprising Xenarthra and Afrotheria as the sister group to Boreotheria comprising all remaining placentals) by eight insertion patterns. These findings provide significant support for a “soft” polytomy of the major mammalian clades. Ancestral successive hybridization events and/or incomplete lineage sorting associated with short speciation intervals are viable explanations for the mosaic retroposon insertion patterns of recent placental mammals and for the futile search for a clear root dichotomy. PMID:19261842

  18. True anteroposterior view pedicle screw insertion technique

    PubMed Central

    Bai, Jia-yue; Zhang, Wei; An, Ji-long; Sun, Ya-peng; Ding, Wen-yuan; Shen, Yong

    2016-01-01

    Background The wide use of minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) surgery in the treatment of degenerative disc disease of lumbar spine in spinal surgery highlights the gradual decrease in the use of traditional pedicle screw insertion technology. This study aims to analyze the accuracy of the true anteroposterior view pedicle screw insertion technique in MIS-TLIF surgery, compare it with conventional pedicle screw insertion technology, and discuss its clinical application value. Methods Fifty-two patients undergoing true anteroposterior view (group A) and 87 patients undergoing conventional pedicle screw insertion (group B) were diagnosed with lumbar disc herniation or lumbar spinal stenosis. Time for screw placement, intraoperative irradiation exposure, accuracy rate of pedicle screw insertion, and incidence of neurovascular injury were compared between the two groups. Results The time for screw placement and intraoperative irradiation exposure was significantly less in group A. Penetration rates of the paries lateralis of vertebral pedicle, medial wall of vertebral pedicle, and anterior vertebral wall were 1.44%, 0%, and 2.40%, respectively, all of which were significantly lower than that in group B. No additional serious complications caused by the placement of screw were observed during the follow-up period in patients in group A, but two patients with medial penetration underwent revision for unbearable radicular pain. Conclusion The application of true anteroposterior view pedicle screw insertion technique in MIS-TLIF surgery shortens time for screw placement and reduces the intraoperative irradiation exposure along with a higher accuracy rate of screw placement, which makes it a safe, accurate, and efficient technique. PMID:27418828

  19. Mosaic retroposon insertion patterns in placental mammals.

    PubMed

    Churakov, Gennady; Kriegs, Jan Ole; Baertsch, Robert; Zemann, Anja; Brosius, Jürgen; Schmitz, Jürgen

    2009-05-01

    One and a half centuries after Charles Darwin and Alfred Russel Wallace outlined our current understanding of evolution, a new scientific era is dawning that enables direct observations of genetic variation. However, pure sequence-based molecular attempts to resolve the basal origin of placental mammals have so far resulted only in apparently conflicting hypotheses. By contrast, in the mammalian genomes where they were highly active, the insertion of retroelements and their comparative insertion patterns constitute a neutral, virtually homoplasy-free archive of evolutionary histories. The "presence" of a retroelement at an orthologous genomic position in two species indicates their common ancestry in contrast to its "absence" in more distant species. To resolve the placental origin controversy we extracted approximately 2 million potentially phylogenetically informative, retroposon-containing loci from representatives of the major placental mammalian lineages and found highly significant evidence challenging all current single hypotheses of their basal origin. The Exafroplacentalia hypothesis (Afrotheria as the sister group to all remaining placentals) is significantly supported by five retroposon insertions, the Epitheria hypothesis (Xenarthra as the sister group to all remaining placentals) by nine insertion patterns, and the Atlantogenata hypothesis (a monophyletic clade comprising Xenarthra and Afrotheria as the sister group to Boreotheria comprising all remaining placentals) by eight insertion patterns. These findings provide significant support for a "soft" polytomy of the major mammalian clades. Ancestral successive hybridization events and/or incomplete lineage sorting associated with short speciation intervals are viable explanations for the mosaic retroposon insertion patterns of recent placental mammals and for the futile search for a clear root dichotomy.

  20. Compact insert design for cryogenic pressure vessels

    DOEpatents

    Aceves, Salvador M.; Ledesma-Orozco, Elias Rigoberto; Espinosa-Loza, Francisco; Petitpas, Guillaume; Switzer, Vernon A.

    2017-06-14

    A pressure vessel apparatus for cryogenic capable storage of hydrogen or other cryogenic gases at high pressure includes an insert with a parallel inlet duct, a perpendicular inlet duct connected to the parallel inlet. The perpendicular inlet duct and the parallel inlet duct connect the interior cavity with the external components. The insert also includes a parallel outlet duct and a perpendicular outlet duct connected to the parallel outlet duct. The perpendicular outlet duct and the parallel outlet duct connect the interior cavity with the external components.

  1. RERTR-12 Insertion 2 Irradiation Summary Report

    SciTech Connect

    D. M. Perez; G. S. Chang; D. M. Wachs; G. A. Roth; N. E. Woolstenhulme

    2012-09-01

    The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-12 was designed to provide comprehensive information on the performance of uranium-molybdenum (U-Mo) based monolithic fuels for research reactor applications.1 RERTR-12 insertion 2 includes the capsules irradiated during the last three irradiation cycles. These capsules include Z, Y1, Y2 and Y3 type capsules. The following report summarizes the life of the RERTR-12 insertion 2 experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.

  2. Interaural attenuation using insert earphones: electrocochleographic approach.

    PubMed

    Sobhy, O A; Gould, H J

    1993-03-01

    We measured the interaural attenuation for click stimuli using insert earphones. Electrocochleographic thresholds were determined when clicks were presented both ipsilaterally and contralaterally to the recording ear. The interaural attenuation was calculated as the difference between ipsilateral and contralateral thresholds. Results from normal listeners showed that crossover occurred. Results agree with previous investigators who used a different approach. Results confirm that one may need to mask the nontest ear in clinical evoked potential testing even though insert earphones are used. Several approaches to the question of when to mask are proposed.

  3. Circular permutant GFP insertion folding reporters

    SciTech Connect

    Waldo, Geoffrey S.; Cabantous, Stephanie

    2013-04-16

    Provided are methods of assaying and improving protein folding using circular permutants of fluorescent proteins, including circular permutants of GFP variants and combinations thereof. The invention further provides various nucleic acid molecules and vectors incorporating such nucleic acid molecules, comprising polynucleotides encoding fluorescent protein circular permutants derived from superfolder GFP, which polynucleotides include an internal cloning site into which a heterologous polynucleotide may be inserted in-frame with the circular permutant coding sequence, and which when expressed are capable of reporting on the degree to which a polypeptide encoded by such an inserted heterologous polynucleotide is correctly folded by correlation with the degree of fluorescence exhibited.

  4. Circular permutant GFP insertion folding reporters

    DOEpatents

    Waldo, Geoffrey S.; Cabantous, Stephanie

    2008-06-24

    Provided are methods of assaying and improving protein folding using circular permutants of fluorescent proteins, including circular permutants of GFP variants and combinations thereof. The invention further provides various nucleic acid molecules and vectors incorporating such nucleic acid molecules, comprising polynucleotides encoding fluorescent protein circular permutants derived from superfolder GFP, which polynucleotides include an internal cloning site into which a heterologous polynucleotide may be inserted in-frame with the circular permutant coding sequence, and which when expressed are capable of reporting on the degree to which a polypeptide encoded by such an inserted heterologous polynucleotide is correctly folded by correlation with the degree of fluorescence exhibited.

  5. Circular permutant GFP insertion folding reporters

    DOEpatents

    Waldo, Geoffrey S; Cabantous, Stephanie

    2013-02-12

    Provided are methods of assaying and improving protein folding using circular permutants of fluorescent proteins, including circular permutants of GFP variants and combinations thereof. The invention further provides various nucleic acid molecules and vectors incorporating such nucleic acid molecules, comprising polynucleotides encoding fluorescent protein circular permutants derived from superfolder GFP, which polynucleotides include an internal cloning site into which a heterologous polynucleotide may be inserted in-frame with the circular permutant coding sequence, and which when expressed are capable of reporting on the degree to which a polypeptide encoded by such an inserted heterologous polynucleotide is correctly folded by correlation with the degree of fluorescence exhibited.

  6. Circular permutant GFP insertion folding reporters

    DOEpatents

    Waldo, Geoffrey S.; Cabantous, Stephanie

    2011-06-14

    Provided are methods of assaying and improving protein folding using circular permutants of fluorescent proteins, including circular permutants of GFP variants and combinations thereof. The invention further provides various nucleic acid molecules and vectors incorporating such nucleic acid molecules, comprising polynucleotides encoding fluorescent protein circular permutants derived from superfolder GFP, which polynucleotides include an internal cloning site into which a heterologous polynucleotide may be inserted in-frame with the circular permutant coding sequence, and which when expressed are capable of reporting on the degree to which a polypeptide encoded by such an inserted heterologous polynucleotide is correctly folded by correlation with the degree of fluorescence exhibited.

  7. Traumatic insertion of eyelashes into corneal stroma.

    PubMed

    Casswell, Edward J; Anikina, Evgenia V; Mearza, Ali A

    2014-10-01

    An unusual case of eyelashes being traumatically inserted into the corneal stroma is presented. A 75-year-old hit her right eye with her own fist, presenting with intra-corneal eyelashes. All remained entirely within the cornea, with no breach of the endothelium. They seemed to have tracked there first through the superior conjunctiva and then the superior limbus. The lashes were surgically removed, with good visual recovery. The authors present a short review of intra-ocular eyelash insertion. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  8. Friction force measurement during cochlear implant insertion: application to a force-controlled insertion tool design.

    PubMed

    Miroir, Mathieu; Nguyen, Yann; Kazmitcheff, Guillaume; Ferrary, Evelyne; Sterkers, Olivier; Grayeli, Alexis Bozorg

    2012-08-01

    The aim of the study was to evaluate force profiles during array insertion in human cochlea specimens and to evaluate a mechatronic inserter using a 1-axis force sensor. Today, the surgical challenge in cochlear implantation is the preservation of the anatomic structures and the residual hearing. In routine practice, the electrode array is inserted manually with a limited sensitive feedback. Hifocus 1J electrode arrays were studied. The bench test comprised a mechatronic inserter combined to a 1-axis force sensor between the inserter and the base of the array and a 6-axis force sensor beneath the cochlea model. Influence of insertion tube material, speed (0.15, 0.5, and 1.5 mm/s) and lubricant on frictions forces were studied (no-load). Different models were subsequently evaluated: epoxy scala tympani model and temporal bones. Frictions forces were lower in the plastic tube compared with those in the metal tube (0.09 ± 0.028 versus 0.14 ± 0.034 at 0.5 mm/s, p < 0.001) and with the use of hyaluronic acid gel. Speed did not influence frictions forces in our study. Insertion force profiles provided by the 1- and 6-axis force sensors were similar when friction forces inside the insertion tool (no-load measurements) were subtracted from the 1-axis sensor data in the epoxy and temporal bone models (mean error, 0.01 ± 0.001 N). Using a sensor included in the inserter, we were able to measure array insertion forces. This tool can be potentially used to provide real-time information to the surgeon during the procedure.

  9. Insertional Achilles tendinitis and Haglund's deformity.

    PubMed

    Kang, Steve; Thordarson, David B; Charlton, Timothy P

    2012-06-01

    Haglund's deformity is an enlargement of the posterosuperior prominence of the calcaneus, which is frequently associated with insertional Achilles tendinitis. To our knowledge, no study has been done successfully correlating the characteristics of a Haglund's deformity with insertional Achilles tendinitis. The purpose of our study was to analyze the characteristics of a Haglund's deformity in patients with and without insertional Achilles tendinitis to see if there was a correlation. The study was a retrospective radiographic review of a single surgeon's patients with insertional Achilles tendinitis from 2005 to 2008. Our study population consisted of 44 patients, 48 heels (22 male, 22 female) with insertional Achilles tendinitis, with a mean age of 52 (range, 23 to 79) years. Our control population consisted of 50 patients (25 males, 25 females) and 50 heels without insertional Achilles tendinitis with a mean age of 55.6 (range, 18 to 89) years. We introduced two new measurements of the Haglund's deformity in this study: the Haglund's deformity height and peak angle. A standing lateral foot or ankle radiograph was analyzed for each patient and the following measurements were made: Haglund deformity height and peak angle; Bohler's angle; Fowler-Philip angle; and parallel pitch sign. We also looked for the presence of calcification in the study group and the length and width of the calcification. Unpaired t-test was used to analyze the measurements between the groups. Ten patients' radiographs were re-measured and correlation coefficients were obtained to assess the reliability of the measuring techniques. For the insertional Achilles tendinitis group, the mean Haglund's deformity height was 9.6 (range, 5.3 to 15.3) mm and the mean Haglund's deformity peak angle was 105 (range, 87 to 123) degrees. Calcification was present in 35 of 48 or (73%) of patients with a mean length of 13.3 (range, 3.2 to 41.9) mm and mean width of 4.5 (range, 1.0 to 10.4) mm. In the control

  10. 21 CFR 886.5420 - Contact lens inserter/remover.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Contact lens inserter/remover. 886.5420 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5420 Contact lens inserter/remover. (a) Identification. A contact lens inserter/remover is a handheld device intended to insert or...

  11. 21 CFR 886.5420 - Contact lens inserter/remover.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Contact lens inserter/remover. 886.5420 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5420 Contact lens inserter/remover. (a) Identification. A contact lens inserter/remover is a handheld device intended to insert or...

  12. 21 CFR 886.5420 - Contact lens inserter/remover.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Contact lens inserter/remover. 886.5420 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5420 Contact lens inserter/remover. (a) Identification. A contact lens inserter/remover is a handheld device intended to insert or...

  13. 21 CFR 886.5420 - Contact lens inserter/remover.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens inserter/remover. 886.5420 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5420 Contact lens inserter/remover. (a) Identification. A contact lens inserter/remover is a handheld device intended to insert or...

  14. 21 CFR 886.5420 - Contact lens inserter/remover.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Contact lens inserter/remover. 886.5420 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5420 Contact lens inserter/remover. (a) Identification. A contact lens inserter/remover is a handheld device intended to insert or...

  15. Embedded Multiprocessor Technology for VHSIC Insertion

    NASA Technical Reports Server (NTRS)

    Hayes, Paul J.

    1990-01-01

    Viewgraphs on embedded multiprocessor technology for VHSIC insertion are presented. The objective was to develop multiprocessor system technology providing user-selectable fault tolerance, increased throughput, and ease of application representation for concurrent operation. The approach was to develop graph management mapping theory for proper performance, model multiprocessor performance, and demonstrate performance in selected hardware systems.

  16. Lymphatic Leak Complicating Central Venous Catheter Insertion

    SciTech Connect

    Barnacle, Alex M. Kleidon, Tricia M.

    2005-12-15

    Many of the risks associated with central venous access are well recognized. We report a case of inadvertent lymphatic disruption during the insertion of a tunneled central venous catheter in a patient with raised left and right atrial pressures and severe pulmonary hypertension, which led to significant hemodynamic instability. To our knowledge, this rare complication is previously unreported.

  17. Thermal Performance of the XRS Helium Insert

    NASA Technical Reports Server (NTRS)

    Breon, Susan R.; DiPirro, Michael J.; Tuttle, James G.; Shirron, Peter J.; Warner, Brent A.; Boyle, Robert F.; Canavan, Edgar R.

    1999-01-01

    The X-Ray Spectrometer (XRS) is an instrument on the Japanese Astro-E satellite, scheduled for launch early in the year 2000. The XRS Helium Insert comprises a superfluid helium cryostat, an Adiabatic Demagnetization Refrigerator (ADR), and the XRS calorimeters with their cold electronics. The calorimeters are capable of detecting X-rays over the energy range 0.1 to 10 keV with a resolution of 12 eV. The Helium Insert completed its performance and verification testing at Goddard in January 1999. It was shipped to Japan, where it has been integrated with the neon dewar built by Sumitomo Heavy Industries. The Helium Insert was given a challenging lifetime requirement of 2.0 years with a goal of 2.5 years. Based on the results of the thermal performance tests, the predicted on-orbit lifetime is 2.6 years with a margin of 30%. This is the result of both higher efficiency in the ADR cycle and the low temperature top-off, more than compensating for an increase in the parasitic heat load. This paper presents a summary of the key design features and the results of the thermal testing of the XRS Helium Insert.

  18. Peripherally inserted central catheters. Intravenous Nurses Society.

    PubMed

    1997-01-01

    The Intravenous Nurses Society (INS) recognizes the need for uniform terminology for peripherally inserted central catheters (PICCs) to encourage standardization for indications, care, and maintenance strategies for these devices. It also recognizes the need for recommendations regarding the choice, use, management, and discontinuation of PICCs to promote positive patient outcomes and enhance patient comfort, safety, and satisfaction.

  19. Patients' experiences of the PICC insertion procedure.

    PubMed

    Nicholson, Jackie; Davies, Louise

    Peripherally inserted central catheters (PICCs) are a type of central venous access device used to deliver a variety of intravenous therapies, including chemotherapy. PICCs may be placed by interventional radiologists, anaesthetists or, as is increasingly common, by specialist nurses in the hospital setting. However, little is known about how patients feel regarding the PICC insertion procedure. The aim of this study was to interview patients who had undergone a recent PICC insertion in the chemotherapy day unit to identify their experiences. On analysis of the qualitative data obtained from the semi-structured interview, five themes emerged: the context of cancer; expectations; levels of pain and anxiety; coping strategies; and explanation. The findings of this study support some previously described elements of procedural experiences; however, new understanding has provided implications for practice in the areas of expectations, allaying anxiety levels, supporting individual coping strategies and providing explanation. The major limitation of the study was the homogenous sample of oncology patients with a clear link between the patient experience of the PICC insertion and the context of cancer. The main recommendation for further research would be to repeat this study with a broader patient population.

  20. Insertion Loss of Personal Protective Clothing

    SciTech Connect

    Shull D.J.; Biesel, V.B.; Cunefare, K.A.

    1999-05-13

    'The use of personal protective clothing that covers the head is a common practice in many industries. Such personal protective clothing will impact the sound pressure level and the frequency content of sounds to which the wearer will be exposed. The use of such clothing, then, may impact speech and alarm audibility. A measure of the impact of such clothing is its insertion loss. Insertion loss measurements were performed on four types of personal protective clothing in use by Westinghouse Savannah River Company personnel which utilize cloth and plastic hood configurations to protect the head. All clothing configurations tested at least partially cover the ears. The measurements revealed that insertion loss of the items tested was notable at frequencies above 1000 Hz only and was a function of material stiffness and acoustic flanking paths to the ear. Further, an estimate of the clothing''s noise reduction rating reveals poor performance in that regard, even though the insertion loss of the test articles was significant at frequencies at and above 1000 Hz.'

  1. Immediate postabortal insertion of intrauterine devices.

    PubMed

    Okusanya, Babasola O; Oduwole, Olabisi; Effa, Emmanuel E

    2014-07-28

    Background The use of an effective contraceptive may be necessary after an abortion. Insertion of an intrauterine device (IUD) may be done the same day or later. Immediate IUD insertion is an option since the woman is not pregnant, pain of insertion is less because the cervical os is open, and her motivation to use contraception may be high. However, insertion of an IUD immediately after a pregnancy ends carries risks, such as spontaneous expulsion.Objectives To assess the safety and efficacy of IUD insertion immediately after spontaneous or induced abortion.Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, POPLINE, ClinicalTrials.gov,and ICTRP in January 27, 2014. We also contacted investigators to identify other trials.Selection criteria We sought all randomised controlled trials (RCTs) with at least one treatment arm that involved IUD insertion immediately after an induced abortion or after curettage for spontaneous abortion.Data collection and analysis We evaluated the methodological quality of each report and abstracted the data. We focused on discontinuation rates for accidental pregnancy, perforation, expulsion, and pelvic inflammatory disease.We computed the weighted average of the rate ratios.We compute drisk ratios (RRs) with 95% Confidence Intervals (CIs).We performed an intention-to-treat (ITT) analysis by including all randomised participants in the analysis according to the Cochrane Handbook for Systematic Reviews of Interventions.Main results We identified 12 trials most of which are of moderate risk of bias involving 7,119 participants which described random assignment.Five trials randomised to either immediate or delayed insertion of IUD. One of them randomised to immediate versus delayed insertion of Copper 7 showed immediate insertion of the Copper 7 was associated with a higher risk of expulsion than was delayed insertion(RR 11.98, 95% CI 1.61 to 89.35,1 study, 259 participants); the

  2. Frequency, Gradience, and Variation in Consonant Insertion

    ERIC Educational Resources Information Center

    An, Young-ran

    2010-01-01

    This dissertation addresses the extent to which linguistic behavior can be described in terms of the projection of patterns from existing lexical items, through an investigation of Korean reduplication. Korean has a productive pattern of reduplication in which a consonant is inserted in a vowel-initial base, illustrated by forms such as "alok"--"t…

  3. Mars Observer Lecture: Mars Orbit Insertion

    NASA Technical Reports Server (NTRS)

    Dodd, Suzanne R. (Personal Name)

    1993-01-01

    The Mars Observer mission spacecraft was primarily designed for exploring Mars and the Martian environment. The Mars Observer was launched on September 25, 1992. The spacecraft was lost in the vicinity of Mars on August 21, 1993 when the spacecraft began its maneuvering sequence for Martian orbital insertion. This videotape shows a lecture by Suzanne R. Dodd, the Mission Planning Team Chief for the Mars Observer Project. Ms Dodd begins with a brief overview of the mission and the timeline from the launch to orbital insertion. Ms Dodd then reviews slides showing the trajectory of the spacecraft on its trip to Mars. Slides of the spacecraft being constructed are also shown. She then discusses the Mars orbit insertion and the events that will occur to move the spacecraft from the capture orbit into a mapping orbit. During the trip to Mars, scientists at JPL had devised a new strategy, called Power In that would allow for an earlier insertion into the mapping orbit. The talk summarizes this strategy, showing on a slide the planned transition orbits. There are shots of the Martian moon, Phobos, taken from the Viking spacecraft, as Ms Dodd explains that the trajectory will allow the orbiter to make new observations of that moon. She also explains the required steps to prepare for mapping after the spacecraft has achieved the mapping orbit around Mars. The lecture ends with a picture of Mars from the Observer on its approach to the planet.

  4. Inserting new technology into small missions

    NASA Technical Reports Server (NTRS)

    Deutsch, L. J.

    2001-01-01

    Part of what makes small missions small is that they have less money. Executing missions at low cost implies extensive use of cost sharing with other missions or use of existing solutions. Luckily, there are methods for creating new technology and inserting it into faster-better-cheaper missions.

  5. A design for vertical crossing insertions

    SciTech Connect

    Garren, A.

    1985-10-01

    A crossing insertion designed for an SSC with vertically separated 1-in-1 beam lines is presented in this note. The author supposes that the beam lines consist of separate magnets in separate cryostats separated by about 70 cm. He then describes the design, where vertical separation is done with four vertical dipoles producing a steplike beam line.

  6. Insertion loads and forearm muscle activity during flexible hose insertion tasks.

    PubMed

    Grieshaber, D Christian; Armstrong, Thomas J

    2007-10-01

    To quantify the physical demands of hose insertion tasks in automotive assembly operations and how they are affected by method and the mechanical interference between the hose and the flange. Insertion tasks were identified by workers as physically demanding and can often lead to fatigue or losses in production attributable to pain or injury. Six male and 6 female participants pushed a 25.4-mm flexible rubber hose onto a stationary flange during simulated insertions. Three insertion methods -- rock, straight, and twist -- were examined in the study. Muscle activity of the finger flexors was recorded to estimate grip effort during the simulated insertions. The twist method (114.8 N) resulted in a 26% reduction in axial force compared with the straight method (155.7 N). Average muscle activity ranged from a low of 14% maximum voluntary contraction (MVC; men, straight method) to a high of 67% MVC (women, twist method). Hose resultant forces ranged from a low of 52.2 N to a high of 461.1 N for all participants. Men exerted 6% higher resultant forces with 37% less muscle activity than women. There are situations when the 26% reduction in the axial force attributable to twisting may be helpful during an insertion, despite the fact that forearm muscle activity was highest for both male and female participants during twisting insertions. The results of this study can be applied to the future design of tasks that involve the joining of two parts such as a hose and flange.

  7. Prenatal diagnosis of abnormal umbilical cord insertion: a rare case of furcate insertion.

    PubMed

    Fujita, Yasuyuki; Yumoto, Yasuo; Kato, Kiyoko

    2017-04-01

    Furcate insertion (FI) is an extremely rare abnormality of umbilical cord insertion. One of the complications associated with FI is hemorrhage from the umbilical vein at the site of FI of the umbilical cord, which can cause sudden intrauterine fetal death. Because of its rarity, no prenatal diagnosis of FI has been reported. A 31-year-old woman at 34 weeks' gestation was referred to us for suspected abnormal cord insertion. Ultrasonography showed normal fetal growth and amniotic fluid volume, with no fetal anomalies. Although the umbilical cord contained three vessels inserted at the center of the placenta, the umbilical vessels separated from the cord substance before their insertion to the placenta. Based on these findings, the patient was diagnosed with FI. During labor at 37 weeks' gestation, fetal heart rate was normal and a healthy neonate was delivered. At macroscopic examination, the umbilical cord was inserted in the middle of the placenta, and the placental parenchymal tissue just under the cord insertion was deficient and had been changed to white, elastic hard tissue. Pathological examination of the white tissue revealed fibrin deposition and focal infarction. Although FI is a very rare condition, prenatal diagnosis can be achieved through detailed color Doppler ultrasound studies. Therefore, taking precautions and keeping in mind the poor fetal outcome associated with FI are preferred.

  8. Consolidation and disposal of PWR fuel inserts

    SciTech Connect

    Wakeman, B.H. )

    1992-08-01

    Design and licensing of the Surry Power Station Independent Spent Fuel Storage Installation was initiated in 1982 by Virginia Power as part of a comprehensive strategy to increase spent fuel storage capacity at the Station. Designed to use large, metal dry storage casks, the Surry Installation will accommodate 84 such casks with a total storage capacity of 811 MTU of spent pressurized water reactor fuel assemblies. Virginia Power provided three storage casks for testing at the Idaho National Engineerinq Laboratory's Test Area North and the testing results have been published by the Electric Power Research Institute. Sixty-nine spent fuel assemblies were transported in truck casks from the Surry Power Station to Test Area North for testing in the three casks. Because of restrictions imposed by the cask testing equipment at Test Area North, the irradiated insert components stored in these fuel assemblies at Surry were removed prior to transport of the fuel assemblies. Retaining these insert components proved to be a problem because of a shortage of spent fuel assemblies in the spent fuel storage pool that did not already contain insert components. In 1987 Virginia Power contracted with Chem-Nuclear Systems, Inc. to process and dispose of 136 irradiated insert components consisting of 125 burnable poison rod assemblies, 10 thimble plugging devices and 1 part-length rod cluster control assembly. This work was completed in August and September 1987, culminating in the disposal at the Barnwell, SC low-level radioactive waste facility of two CNS 3-55 liners containing the consolidated insert components.

  9. Distal Insertions of the Biceps Femoris

    PubMed Central

    Branch, Eric A.; Anz, Adam W.

    2015-01-01

    Background: Avulsion of the biceps femoris from the fibula and proximal tibia is encountered in clinical practice. While the anatomy of the primary posterolateral corner structures has been qualitatively and quantitatively described, a quantitative analysis regarding the insertions of the biceps femoris on the fibula and proximal tibia is lacking. Purpose: To quantitatively assess the insertions of the biceps femoris, fibular collateral ligament (FCL), and anterolateral ligament (ALL) on the fibula and proximal tibia as well as establish relationships among these structures and to pertinent surgical anatomy. Study Design: Descriptive laboratory study. Methods: Dissections were performed on 12 nonpaired, fresh-frozen cadaveric specimens identifying the biceps femoris, FCL, and ALL, and their insertions on the proximal tibia and fibula. The footprint areas, orientations, and distances from relevant osseous landmarks were measured using a 3-dimensional coordinate measurement device. Results: Dissection produced 6 easily identifiable and reproducible anatomic footprints. Tibial footprints included the insertion of the ALL and an insertion of the biceps femoris (TBF). Fibular footprints included the insertion of the FCL, a distal insertion of the biceps femoris (DBF), a medial footprint of the biceps femoris (MBF), and a proximal footprint of the biceps femoris (PBF). The mean area of these footprints (95% CI) was as follows: ALL, 53.0 mm2 (38.4-67.6); TBF, 93.9 mm2 (72.0-115.8); FCL, 86.8 mm2 (72.3-101.2); DBF, 119 mm2 (91.1-146.9); MBF, 46.8 mm2 (29.0-64.5); and PBF, 215 mm2 (192.4-237.5). The mean distance (95% CI) from the Gerdy tubercle to the center of the ALL footprint was 24.3 mm (21.6-27.0) and to the center of the TBF was 22.5 mm (21.0-24.0). The center of the DBF was 8.68 mm (7.0-10.3) from the anterior border of the fibula, the center of the FCL was 14.6 mm (12.5-16.7) from the anterior border of the fibula and 20.7 mm (19.0-22.4) from the tip of the fibular

  10. Mechanistic insights on acrylate insertion polymerization.

    PubMed

    Guironnet, Damien; Caporaso, Lucia; Neuwald, Boris; Göttker-Schnetmann, Inigo; Cavallo, Luigi; Mecking, Stefan

    2010-03-31

    Complexes [{(PwedgeO)PdMe}(n)] (1(n); PwedgeO = kappa(2)-P,O-Ar(2)PC(6)H(4)SO(2)O with Ar = 2-MeOC(6)H(4)) are a single-component precursor of the (PwedgeO)PdMe fragment devoid of additional coordinating ligands, which also promotes the catalytic oligomerization of acrylates. Exposure of 1(n) to methyl acrylate afforded the two diastereomeric chelate complexes [(PwedgeO)Pd{kappa(2)-C,O-CH(C(O)OMe)CH(2)CH(C(O)OMe)CH(2)CH(3)}] (3-meso and 3-rac) resulting from two consecutive 2,1-insertions of methyl acrylate into the Pd-Me bond with the same or opposite stereochemistry, respectively, in a 3:2 ratio as demonstrated by comprehensive NMR spectroscopic studies and single crystal X-ray diffraction. These six-membered chelate complexes are direct key models for intermediates of acrylate insertion polymerization, and also ethylene-acrylate copolymerization to high acrylate content copolymers. Studies of the binding of various substrates (pyridine, dmso, ethylene and methyl acrylate) to 3-meso and 3-rac show that hindered displacement of the chelating carbonyl moiety by pi-coordination of incoming monomer significantly retards, but does not prohibit, polymerization. For 3-meso,3-rac + C(2)H(4) right arrow over left arrow 3-meso-C(2)H(4,) 3-rac-C(2)H(4) an equilibrium constant K(353 K) approximately 2 x 10(-3) L mol(-1) was estimated. Reaction of 3-meso, 3-rac with methyl acrylate afforded higher insertion products [(PwedgeO)Pd(C(4)H(6)O(2))(n)Me] (n = 3, 4) as observed by electrospray ionization mass spectrometry (ESI-MS). Theoretical studies by DFT methods of consecutive acrylate insertion provide relative energies of intermediates and transition states, which are consistent with the aforementioned experimental observations, and give detailed insights to the pathways of multiple consecutive acrylate insertions. Acrylate insertion into 3-meso,3-rac is associated with an overall energy barrier of ca. 100 kJ mol(-1).

  11. Effect of Off-Axis Screw Insertion, Insertion Torque, and Plate Contouring on Locked Screw Strength

    PubMed Central

    Gallagher, Bethany; Silva, Matthew J.; Ricci, William M.

    2015-01-01

    Objectives This study quantifies the effects of insertion torque, off-axis screw angulation, and plate contouring on the strength of locking plate constructs. Methods Groups of locking screws (n = 6–11 screws) were inserted at 50%, 100%, 150%, and 200% of the manufacturer-recommended torque (3.2 Nm) into locking compression plates at various angles: orthogonal (control), 5-degree angle off-axis, and 10-degree angle off-axis. Screws were loaded to failure by a transverse force (parallel to the plate) either in the same (“+”) or opposite direction (“−”) of the initial screw angulation. Separately, locking plates were bent to 5 and 10-degree angles, with the bend apex at a screw hole. Locking screws inserted orthogonally into the apex hole at 100% torque were loaded to failure. Results Orthogonal insertion resulted in the highest average load to failure, 2577 ± 141 N (range, 2413–2778 N), whereas any off-axis insertion significantly weakened constructs (165–1285 N, at 100% torque) (P < 0.05). For “+” loading, torque beyond 100% did not increase strength, but 50% torque reduced screw strength (P < 0.05). Loading in the “−” direction consistently resulted in higher strengths than “+” loading (P < 0.05). Plate contouring of 5-degree angle did not significantly change screw strength compared with straight plates but contouring of 10-degree angle significantly reduced load to failure (P < 0.05). Conclusions To maximize the screw plate interface strength, locking screws should be inserted without cross-threading. The mechanical stability of locked screws is significantly compromised by loose insertion, off-axis insertion, or severe distortion of the locking mechanism. PMID:24343255

  12. Descemet's Stripping Automated Endothelial Keratoplasty Tissue Insertion Devices

    PubMed Central

    Khan, Salman Nasir; Shiakolas, Panos S.; Mootha, Venkateswara Vinod

    2015-01-01

    This review study provides information regarding the construction, design, and use of six commercially available endothelial allograft insertion devices applied for Descemet's stripping automated endothelial keratoplasty (DSAEK). We also highlight issues being faced in DSAEK and discuss the methods through which medical devices such as corneal inserters may alleviate these issues. Inserter selection is of high importance in the DSAEK procedure since overcoming the learning curve associated with the use of an insertion device is a time and energy consuming process. In the present review, allograft insertion devices were compared in terms of design, construction material, insertion technique, dimensions, incision requirements and endothelial cell loss to show their relative merits and capabilities based on available data in the literature. Moreover, the advantages/disadvantages of various insertion devices used for allograft insertion in DSAEK are reviewed and compared. The information presented in this review can be utilized for better selection of an insertion device for DSAEK. PMID:27051492

  13. A Monte Carlo study of peptide insertion into lipid bilayers: equilibrium conformations and insertion mechanisms.

    PubMed Central

    Maddox, Michael W; Longo, Marjorie L

    2002-01-01

    The membrane insertion behavior of two peptides, Magainin2 and M2 delta, was investigated by applying the Monte Carlo simulation technique to a theoretical model. The model included many novel aspects, such as a new semi-empirical lipid bilayer model and a new set of semi-empirical transfer energies, which reproduced the experimental insertion behavior of Magainin2 and M2 delta without parameter fitting. Additionally, we have taken into account diminished internal (intramolecular) hydrogen bonding at the N- and C-termini of helical peptides. All simulations were carried out at 305 K, above the membrane thermal phase transition temperature, and at pH 7.0. The peptide equilibrium conformations are discussed for a range of bilayers with tail polarities varying from octanol-like to alkane-like. Probability distributions of the individual amino-acid-residue positions show the dynamic nature of these equilibrium conformations. Two different insertion mechanisms for M2 delta, and a translocation mechanism for Magainin2, are described. A study of the effect of bilayer thickness on M2 delta insertion suggests a critical thickness above which insertion is unfavorable. Additionally, we did not need to use an orientational potential or array of hard cylinders to persuade M2 delta to insert perpendicular to the membrane surface. Instead, we found that diminished internal hydrogen bonding in the helical conformation anchored the termini in the headgroups and resulted in a nearly perpendicular orientation. PMID:11751313

  14. Two cases of anaphylaxis after laminaria insertion.

    PubMed Central

    Kim, Sang-Hoon; Chang, Yun-Hae; Kim, Woo-Kyoung; Kim, Yoon-Keun; Cho, Sang-Heon; Kim, You-Young; Min, Kyung-Up

    2003-01-01

    Anaphylaxis following laminaria insertion rarely occurs but may be a life-threatening condition. Laminaria tents, prepared from natural sea kelp, are commonly used prior to elective termination of pregnancy to achieve cervical dilatation. We report herein two cases of anaphylaxis caused by IgE-mediated hypersensitivity to laminaria. Two women, each of whom had undergone at least one previous abortion where a laminaria had been utilized, developed anaphylactic reaction following laminaria insertion. The reaction included urticaria, nausea, breathing difficulty, and hypotension. The patients subsequently underwent skin testing and measurement of serum specific IgE level to laminaria extract, and were shown to elicit positive responses to laminaria. The implication and impact of laminaria allergy on gynecologic procedures are significant and this allergy should be included in the list of differential diagnoses for hypersensitive reaction in gynecologic procedures. PMID:14676449

  15. INSERTION DEVICE ACTIVITIES FOR NSLS-II.

    SciTech Connect

    TANABE,T.; HARDER, D.A.; HULBERT, S.; RAKOWSKI, G.; SKARITKA, J.

    2007-06-25

    National Synchrotron Light Source-II (NSLS-II) will be a medium energy storage ring of 3GeV electron beam energy with sub-nm.rad horizontal emittance and top-off capability at 500mA. Damping wigglers will be used not only to reduce the beam emittance but also used as broadband sources for users. Cryo-Permanent Magnet Undulators (CPMUs) are considered for hard X-ray linear device, and permanent magnet based elliptically polarized undulators (EPUs) for variable polarization devices for soft X-ray. 6T superconducting wiggler with minimal fan angle will be installed in the second phase as well as quasi-periodic EPU for VUV and possibly high-temperature superconducting undulator. R&D plans have been established to pursue the performance enhancement of the baseline devices and to design new types of insertion devices. A new insertion device development laboratory will also be established.

  16. A small, insertable oven for boronization

    SciTech Connect

    Brouchous, D.A.; Diebold, D.A.; Doczy, M.L.

    1996-04-01

    A small insertable oven for benchmarking the boronizing characteristics of solid compounds, such as decaborane and carborane, has been developed for the Phaedrus-T tokamak. Assembly and installation of the oven are relatively easy as the oven design utilizes a Langmuir probe drive assembly, which is standard equipment on most tokamaks and allows the oven to be inserted into the tokamak without requiring a vent. Films deposited by heating carborane into the vapor state with the oven are found to be spatially nonuniform in both thickness and in the ratio of boron to carbon as compared to films deposited with trimethylboron, a gaseous compound. Overall plasma performance is not found to be greatly affected by whether decaborane, carborane or trimethylboron is used for boronization in Phaedrus-T. {copyright} {ital 1996 American Institute of Physics.} {lt}ii;010512{gt}

  17. The Evaluation of Some Threaded Inserts

    DTIC Science & Technology

    1979-10-01

    29 600 AVE z 30,400 44 AFML- TR- 78-10/ TABLE 26 RESULTS OF FATIGUE TESTS OF 7078 -T73 ALUMINUM ALLOY WITH 1/4-28 THREADED INSERTS ONLY SPEC. .. NSRT_...PAT INHAT MAX. CYCLES TO C0WMENTS NO. O-BOLT MANUFACTURNA PART NR , INSTALLED STRESS PAILURE INSERT BY AILURE ONLY LOCATION 2-4 -- KAYNAR X8000-4 AFMK...Q r-4C’.1t-- N b C-4 t-4 #-4- w 4) 4J (N(’ IN Nrr N N 04 NINe. N NN Nr -(-N mI I iI IImI -- A",ý ý- . 1.ý ýý ý6%ý - I 79 AFML-TR-78-1 07 I I! I 4. zzI

  18. Perception and Action in Teleoperated Needle Insertion

    PubMed Central

    Nisky, Ilana; Pressman, Assaf; Pugh, Carla M.; Mussa-Ivaldi, Ferdinando A.; Karniel, Amir

    2015-01-01

    We studied the effect of delay on perception and action in contact with a force field that emulates elastic soft tissue with a rigid nonlinear boundary. Such field is similar to forces exerted on a needle during teleoperated needle insertion. We found that delay causes motor underestimation of the stiffness of this nonlinear soft tissue, without perceptual change. These experimental results are supported by simulation of a simplified mechanical model of the arm and neural controller, and a model for perception of stiffness, which is based on regression in the force-position space. In addition, we show that changing the gain of the teleoperation channel cancels the motor effect of delay without adding perceptual distortion. We conclude that it is possible to achieve perceptual and motor transparency in virtual one-dimensional remote needle insertion task. PMID:26379813

  19. Probe Insertion Apparatus with Inflatable Seal

    NASA Technical Reports Server (NTRS)

    Trimarchi, Paul A.

    1991-01-01

    A sealing apparatus for inserting a probe into a pressure vessel having an elongated opening includes Ii pair of resiliently defQrmable seals opposingly disposed in sealing engagement with each other. A retainer is connected to the pressure vessel around the elongated opening and holds the pair of seals rigidly to the pressure vessel. A wedge is engageable with the pair of seals and carries the probe, for longitudinally translating the probe in the pressure vessel.

  20. Comparison of Insertional RNA Editing in Myxomycetes

    PubMed Central

    Chen, Cai; Frankhouser, David; Bundschuh, Ralf

    2012-01-01

    RNA editing describes the process in which individual or short stretches of nucleotides in a messenger or structural RNA are inserted, deleted, or substituted. A high level of RNA editing has been observed in the mitochondrial genome of Physarum polycephalum. The most frequent editing type in Physarum is the insertion of individual Cs. RNA editing is extremely accurate in Physarum; however, little is known about its mechanism. Here, we demonstrate how analyzing two organisms from the Myxomycetes, namely Physarum polycephalum and Didymium iridis, allows us to test hypotheses about the editing mechanism that can not be tested from a single organism alone. First, we show that using the recently determined full transcriptome information of Physarum dramatically improves the accuracy of computational editing site prediction in Didymium. We use this approach to predict genes in the mitochondrial genome of Didymium and identify six new edited genes as well as one new gene that appears unedited. Next we investigate sequence conservation in the vicinity of editing sites between the two organisms in order to identify sites that harbor the information for the location of editing sites based on increased conservation. Our results imply that the information contained within only nine or ten nucleotides on either side of the editing site (a distance previously suggested through experiments) is not enough to locate the editing sites. Finally, we show that the codon position bias in C insertional RNA editing of these two organisms is correlated with the selection pressure on the respective genes thereby directly testing an evolutionary theory on the origin of this codon bias. Beyond revealing interesting properties of insertional RNA editing in Myxomycetes, our work suggests possible approaches to be used when finding sequence motifs for any biological process fails. PMID:22383871

  1. J85 Rejuvenation Through Technology Insertion

    DTIC Science & Technology

    2000-10-01

    and Sabre 75 business addition to military production, the J85 was jets . Number Model Produced Aircraft Type(s) Engine Type Thrust (lbs) J85-GE-4 740...REJUVENATION THROUGH TECHNOLOGY INSERTION T.A. Brisken, P.N. Howell, A.C. Ewing Military Engines Operation GE Aircraft Engines 1 Neumann Way Cincinnati...OH 45215, USA Summary thrust to weight ratio turbojet engines with potential application to early cruise missiles and drones. The history of the

  2. Anionic phospholipids modulate peptide insertion into membranes.

    PubMed

    Liu, L P; Deber, C M

    1997-05-06

    While the insertion of a hydrophobic peptide or membrane protein segment into the bilayer can be spontaneous and driven mainly by the hydrophobic effect, anionic lipids, which comprise ca. 20% of biological membranes, provide a source of electrostatic attractions for binding of proteins/peptides into membranes. To unravel the interplay of hydrophobicity and electrostatics in the binding of peptides into membranes, we designed peptides de novo which possess the typical sequence Lys-Lys-Ala-Ala-Ala-X-Ala-Ala-Ala-Ala-Ala-X-Ala-Ala-Trp-Ala-Ala-X-Ala-Al a-Ala-Lys-Lys-Lys-Lys-amide, where X residues correspond to "guest" residues which encompass a range of hydrophobicity (Leu, Ile, Gly, and Ser). Circular dichroism spectra demonstrated that peptides were partially (40-90%) random in aqueous buffer but were promoted to form 100% alpha-helical structures by anionic lipid micelles. In neutral lipid micelles, only the relatively hydrophobic peptides (X = L and I) spontaneously adopted the alpha-helical conformation, but when 25% of negatively charged lipids were mixed in to mimic the content of anionic lipids in biomembranes, the less hydrophobic (X = S and G) peptides then formed alpha-helical conformations. Consistent with these findings, fluorescence quenching by the aqueous-phase quencher iodide indicated that in anionic (dimyristoylphosphatidylglycerol) vesicles, the peptide Trp residue was buried in the lipid vesicle hydrophobic core, while in neutral (dimyristoylphosphatidylcholine) vesicles, only hydrophobic (X = L and I) peptides were shielded from the aqueous solution. Trp emission spectra of peptides in the presence of phospholipids doxyl-labeled at the 5-, 7-, 10-, 12-, and 16-fatty acid positions implied not only a transbilayer orientation for inserted peptides but also that mixed peptide populations (transbilayer + surface-associated) may arise. Overall results suggest that for hydrophobic peptides with segmental threshold hydrophobicity below that which

  3. Thermally Activated Retainers For Insertion In Gaps

    NASA Technical Reports Server (NTRS)

    Grimaldi, Margaret E.; Hartz, Leslie S.

    1992-01-01

    Mechanical retainers of new type for use with gap filler easy to install and to attach themselves securely. Concept based on shape-memory properties of metal alloy Nitinol, alloy of nickel and titanium. Retainers conceived for use with Space Shuttle insulating tiles but used on other assemblies of blocks or tiles configured similarly. Tabs bent outward made flush by cooling below memory transition temperature. After insertion in gap and reheating, tabs spring outward.

  4. Umbilical cord insertion: normal location in neonates.

    PubMed

    Salgado, L; Paz, J E

    1992-12-01

    The distances between the xyphoid appendix and the insertion point of the umbilical cord (XU) and between the xyphoid appendix and upper edge of the pubic symphysis (XP) were measured in 201 newborn infants. The mean ratio XU/XP was 0.62 (S.D. 0.044) with no differences between sexes nor correlations with weight or length. Ratios lying between 0.53 and 0.71 can be considered as within the normal range.

  5. Comparison of insertional RNA editing in Myxomycetes.

    PubMed

    Chen, Cai; Frankhouser, David; Bundschuh, Ralf

    2012-01-01

    RNA editing describes the process in which individual or short stretches of nucleotides in a messenger or structural RNA are inserted, deleted, or substituted. A high level of RNA editing has been observed in the mitochondrial genome of Physarum polycephalum. The most frequent editing type in Physarum is the insertion of individual Cs. RNA editing is extremely accurate in Physarum; however, little is known about its mechanism. Here, we demonstrate how analyzing two organisms from the Myxomycetes, namely Physarum polycephalum and Didymium iridis, allows us to test hypotheses about the editing mechanism that can not be tested from a single organism alone. First, we show that using the recently determined full transcriptome information of Physarum dramatically improves the accuracy of computational editing site prediction in Didymium. We use this approach to predict genes in the mitochondrial genome of Didymium and identify six new edited genes as well as one new gene that appears unedited. Next we investigate sequence conservation in the vicinity of editing sites between the two organisms in order to identify sites that harbor the information for the location of editing sites based on increased conservation. Our results imply that the information contained within only nine or ten nucleotides on either side of the editing site (a distance previously suggested through experiments) is not enough to locate the editing sites. Finally, we show that the codon position bias in C insertional RNA editing of these two organisms is correlated with the selection pressure on the respective genes thereby directly testing an evolutionary theory on the origin of this codon bias. Beyond revealing interesting properties of insertional RNA editing in Myxomycetes, our work suggests possible approaches to be used when finding sequence motifs for any biological process fails.

  6. STS-115 Preflight Documentation - Post Insertion Training

    NASA Image and Video Library

    2005-12-12

    JSC2005-E-47411 (12 Dec. 2005) --- Astronauts Heidemarie M. Stefanyshyn-Piper (foreground) and Joseph R. (Joe) Tanner, both STS-115 mission specialists, give a thumbs-up signal to indicate preparedness for a training session in one of the full-scale trainers in the Space Vehicle Mockup Facility at Johnson Space Center. Attired in training versions of the shuttle launch and entry suit, the two are seated on the middeck for a post insertion training session.

  7. Probe insertion apparatus with inflatable seal

    NASA Technical Reports Server (NTRS)

    Trimarchi, Paul A. (Inventor)

    1990-01-01

    A sealing apparatus is disclosed for inserting a probe into a pressure vessel having an elongated opening includes a pair of resiliently deformable seals opposingly disposed in sealing engagement with each other. A retainer is connected to the pressure vessel around the elongated opening and holds the pair of seals rigidly to the pressure vessel. A wedge is engageable with the pair of seals and carries the probe, for longitudinally translating the probe in pressure vessel.

  8. Thermally Activated Retainers For Insertion In Gaps

    NASA Technical Reports Server (NTRS)

    Grimaldi, Margaret E.; Hartz, Leslie S.

    1992-01-01

    Mechanical retainers of new type for use with gap filler easy to install and to attach themselves securely. Concept based on shape-memory properties of metal alloy Nitinol, alloy of nickel and titanium. Retainers conceived for use with Space Shuttle insulating tiles but used on other assemblies of blocks or tiles configured similarly. Tabs bent outward made flush by cooling below memory transition temperature. After insertion in gap and reheating, tabs spring outward.

  9. Inserting new technology into small missions

    NASA Technical Reports Server (NTRS)

    Deutsch, L. J.

    2001-01-01

    Part of what makes small missions small is that they have less money. Executing missions at low cost implies extensive use of cost sharing with other missions or use of existing solutions. However, in order to create many small missions, new technology must be developed, applied, and assimilated. Luckily, there are methods for creating new technology and inserting it into faster-better-cheaper (FBC) missions.

  10. Effect of a CoFeB layer on the anisotropic magnetoresistance of Ta/CoFeB/MgO/NiFe/MgO/CoFeB/Ta films

    NASA Astrophysics Data System (ADS)

    Li, Minghua; Shi, Hui; Dong, Yuegang; Ding, Lei; Han, Gang; Zhang, Yao; Liu, Ye; Yu, Guanghua

    2017-10-01

    The anisotropic magnetoresistance (AMR) and magnetic properties of NiFe films can be remarkably enhanced via CoFeB layer. In the case of an ultrathin NiFe film having a Ta/CoFeB/MgO/NiFe/MgO/CoFeB/Ta structure, the CoFeB/MgO layers suppressed the formation of magnetic dead layers and the interdiffusions and interface reactions between the NiFe and Ta layers. The AMR reached a maximum value of 3.56% at 450 °C. More importantly, a single NiFe (1 1 1) peak can be formed resulting in higher AMR values for films having CoFeB layer. This enhanced AMR also originated from the significant specular reflection of electrons owing to the crystalline MgO layer, together with the sharp interfaces with the NiFe layer. These factors together resulted in higher AMR and improved magnetic properties.

  11. DEVICE FOR CONTROLLING INSERTION OF ROD

    DOEpatents

    Beaty, B.J.

    1958-10-14

    A device for rapidly inserting a safety rod into a nuclear reactor upon a given signal or in the event of a power failure in order to prevent the possibility of extensive damage caused by a power excursion is described. A piston is slidably mounted within a vertical cylinder with provision for an electromagnetic latch at the top of the cylinder. This assembly, with a safety rod attached to the piston, is mounted over an access port to the core region of the reactor. The piston is normally latched at the top of the cylinder with the safety rod clear of the core area, however, when the latch is released, the piston and rod drop by their own weight to insert the rod. Vents along the side of the cylinder permit the escape of the air entrapped under the piston over the greater part of the distance, however, at the end of the fall the entrapped air is compressed thereby bringing the safety rod gently to rest, thus providing for a rapid automatic insertion of the rod with a minimum of structural shock.

  12. Beamline Insertions Manager at Jefferson Lab

    SciTech Connect

    Johnson, Michael C.

    2015-09-01

    The beam viewer system at Jefferson Lab provides operators and beam physicists with qualitative and quantitative information on the transverse electron beam properties. There are over 140 beam viewers installed on the 12 GeV CEBAF accelerator. This paper describes an upgrade consisting of replacing the EPICS-based system tasked with managing all viewers with a mixed system utilizing EPICS and high-level software. Most devices, particularly the beam viewers, cannot be safely inserted into the beam line during high-current beam operations. Software is partly responsible for protecting the machine from untimely insertions. The multiplicity of beam-blocking and beam-vulnerable devices motivates us to try a data-driven approach. The beamline insertions application components are centrally managed and configured through an object-oriented software framework created for this purpose. A rules-based engine tracks the configuration and status of every device, along with the beam status of the machine segment containing the device. The application uses this information to decide on which device actions are allowed at any given time.

  13. App-assisted external ventricular drain insertion.

    PubMed

    Eftekhar, Behzad

    2016-09-01

    The freehand technique for insertion of an external ventricular drain (EVD) is based on fixed anatomical landmarks and does not take individual variations into consideration. A patient-tailored approach based on augmented-reality techniques using devices such as smartphones can address this shortcoming. The Sina neurosurgical assist (Sina) is an Android mobile device application (app) that was designed and developed to be used as a simple intraoperative neurosurgical planning aid. It overlaps the patient's images from previously performed CT or MRI studies on the image seen through the device camera. The device is held by an assistant who aligns the images and provides information about the relative position of the target and EVD to the surgeon who is performing EVD insertion. This app can be used to provide guidance and continuous monitoring during EVD placement. The author describes the technique of Sina-assisted EVD insertion into the frontal horn of the lateral ventricle and reports on its clinical application in 5 cases as well as the results of ex vivo studies of ease of use and precision. The technique has potential for further development and use with other augmented-reality devices.

  14. U-insertion/deletion Edited Sequence Database.

    PubMed

    Simpson, L; Wang, S H; Thiemann, O H; Alfonzo, J D; Maslov, D A; Avila, H A

    1998-01-01

    Uridine insertion/deletion RNA editing is a post-transcriptional RNA modification occurring in the mitochondria of kinetoplastid protozoa. The U-insertion/deletion Edited Sequence Database is a compilation of mitochondrial genes and edited mRNAs from five kinetoplastid species. It contains separate files with the DNA, mRNA (both unedited and edited) and predicted protein sequences, as well as alignments of the Leishmania tarentolae and Trypanosoma brucei protein sequences from edited and unedited genes. The sequence files are in GCG format. A 'map' sequence file showing the location of U-deletions, U-insertions and the translated amino acid sequences is also provided for each gene. Genomic maps for each species are also provided with clickable genes, including maxicircle-encoded gRNAs. Sets of aligned nuclear rRNA sequences from kinetoplastid protozoa are also provided, which were used for phylogenetic reconstructions in an analysis of the origin of RNA editing. The database is available through the World Wide Web as an HTML document at the URLhttp://www.lifesci.ucla.edu/RNA/trypanosome/ database.html

  15. Rack Insertion End Effector (RIEE) guidance

    NASA Technical Reports Server (NTRS)

    Malladi, Narasimha S.

    1994-01-01

    NASA-KSC has developed a mechanism to handle and insert Racks into the Space Station Logistic Modules. This mechanism consists of a Base with 3 motorized degrees of freedom, a 3 section motorized Boom that goes from 15 to 44 feet in length, and a Rack Insertion End Effector (RIEE) with 5 hand wheels for precise alignment. During the 1993 NASA-ASEE Summer Faculty Fellowship Program at KSC, I designed an Active Vision (Camera) Arrangement and developed an algorithm to determine (1) the displacements required by the Room for its initial positioning and (2) the rotations required at the five hand-wheels of the RIEE, for the insertion of the Rack, using the centroids fo the Camera Images of the Location Targets in the Logistic Module. Presently, during the summer of '94, I completed the preliminary design of an easily portable measuring instrument using encoders to obtain the 3-Dimensional Coordinates of Location Targets in the Logistics Module relative to the RIEE mechanism frame. The algorithm developed in '93 can use the output of this instrument also. Simplification of the '93 work and suggestions for the future work are discussed.

  16. The study of origin of interfacial perpendicular magnetic anisotropy in ultra-thin CoFeB layer on the top of MgO based magnetic tunnel junction

    NASA Astrophysics Data System (ADS)

    Li, Zhi-Peng; Li, Shaoping; Zheng, Yuankai; Fang, Jason; Chen, Lifan; Hong, Liang; Wang, Haifeng

    2016-10-01

    A comprehensive microstructure study has been conducted experimentally for identifying the origin or mechanism of perpendicular magnetic anisotropy (PMA) in the ultra-thin (10 Å) CoFeB layer on the top of magnetic tunnel junction (MTJ). The high resolution transmission electron microscopy reveals that the feature of crystal structure in 10 Å-CoFeB layer is localized in nature at the CoFeB-MgO interface. On the other hand, the strain-relaxed crystalline structure is observed in the thick CoFeB (20 Å) layer at the CoFeB-MgO interface, associated with a series of dislocation formations. The electron energy loss spectroscopy further suggests that the local chemical stoichiometry of the ultra-thin 10 Å-CoFeB layer is notably changed at the CoFeB-MgO interface, compared with an atomic stoichiometry in a thick 20 Å-CoFeB layer. The origin of PMA mechanism is therefore identified experimentally as an interface effect, which can be attributed to a change of local atom bonding or lattice constant of the transition metal at the CoFeB-MgO based MTJ interface. Furthermore, such a local interfacial atom bonding change is seemly induced by the localized anisotropic strain and consistent with previous theoretical speculations and calculations. The observed experimental findings provide some perspective on microstructure and chemistry on PMA in ultra-thin CoFeB film at the MTJ interface, then deepening our understanding of the mechanism of PMA within MTJ stack and thus facilitating advancement for emerging spintronics technology.

  17. Force measurement of insertion of cochlear implant electrode arrays in-vitro: Comparison of surgeon to automated insertion tool

    PubMed Central

    Majdani, O; Hussong, A; Rau, TS; Wittkopf, J; Lenarz, T; Labadie, RF

    2016-01-01

    Conclusions We have demonstrated that an automated insertion tool (a.k.a. robot) can be used to duplicate a complex surgical motion in inserting cochlear implant electrode arrays via the “advance-off-stylet” technique (AOS). As compared to human operators, the forces generated by the robot were slightly larger but the robot was more reliable (i.e. less force maxima). Objectives We present force data collected during cochlear implant electrode insertion by human operators and by an automated insertion tool (a.k.a. robot). Methods Using a three-dimensional, anatomically-correct, translucent model of the scala tympani chamber of the cochlea, cochlear implant electrodes were inserted either by one of three surgeons (26 insertions) or by the robotic insertion tool (8 insertions). Force was recorded using a load beam cell calibrated for expected forces of less than 0.1 Newtons. The insertions were also videotaped to allow correlation of force with depth of penetration into the cochlea and speed of insertion. Results Average insertion force by the surgeons was 0.004±0.001N and for the insertion tool 0.005±0.014N (p < 0.00001, Student’s t-test). While the average insertion force of the automated tool was larger than that of the surgeons, the surgeons did have intermittent peaks during the AOS component of the insertion (between 120° and 200°). PMID:19484593

  18. Epidural insertion simulator of higher insertion resistance & drop rate after puncture.

    PubMed

    Naemura, K; Sakai, A; Hayashi, T; Saito, H

    2008-01-01

    Accidents such as dural puncture remain one of the problems of epidural anesthesia, and unskilled doctors can repeat such accidents. The purpose of the current research was to provide a new simulator for epidural insertion training. No reference data regarding the resistance force used when inserting a needle into patients have been reported. A comparative study was conducted to aid in the development of a new simulator. Pork loin (n=5) were employed as a substitute for patients. Thickness was set at 2 cm so as to improve the reproducibility. The authors took the conventional simulator apart, and picked a block as an analogue of muscle and ligamentum flavum. A new simulator was made of a melamine foam resin block and a latex rubber sheet. An epidural needle fixed on a motorized stage was inserted at the speed of 2 mm per second. The reaction force was measured while the needle was inserted into each specimen. Waveform of the pork loin exhibited two slopes of different inclines up to peaks and then falls after puncture. The conventional simulator showed a simple increase up to peak and a slow fall after puncture. In contrast, the new simulator showed two slopes up to peak and then a sudden fall after puncture. The insertion resistances were 2.5 N/s for the porcine, 0.8 N/s for the conventional and 2.1 N/s for the new simulator. The drop rates were 5 N/s for the porcine, 0.6 N/s for the conventional and 24 N/s for the new simulator. The higher insertion resistance and drop rate for the new simulator than the conventional simulator will be suitable for epidural insertion training.

  19. 38. INTERIOR VIEW, DENISON MULTIPRESS FOR INSERTION OF WEDGES ONTO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. INTERIOR VIEW, DENISON MULTI-PRESS FOR INSERTION OF WEDGES ONTO HANDLES AND CUTTING OFF SCRAP END OF HANDLE FOLLOWING WEDGE INSERTION, BRIAN KIMBLE, OPERATOR - Warwood Tool Company, Foot of Nineteenth Street, Wheeling, Ohio County, WV

  20. Estimation of insertion depth angle based on cochlea diameter and linear insertion depth: a prediction tool for the CI422.

    PubMed

    Franke-Trieger, Annett; Mürbe, Dirk

    2015-11-01

    Beside the cochlear size, the linear insertion depth (LID) influences the insertion depth angle of cochlear implant electrode arrays. For the specific implant CI422 the recommended LID is not fixed but can vary continuously between 20 and 25 mm. In the current study, the influence of cochlea size and LID on the final insertion depth angle was investigated to develop a prediction tool for the insertion depth angle by means of cochlea diameter and LID. Preoperative estimation of insertion depth angles might help surgeons avoid exceeding an intended insertion depth, especially with respect to low-frequency residual hearing preservation. Postoperative, high-resolution 3D-radiographs provided by Flat Panel Computed Volume Tomography (FPCT) were used to investigate the insertion depth angle in 37 CI422 recipients. Furthermore, the FPCT images were used to measure linear insertion depth and diameter of the basal turn of the cochlea. A considerable variation of measured insertion depth angles ranging from 306° to 579° was identified. The measured linear insertion depth ranged from -18.6 to 26.2 mm and correlated positively with the insertion depth angle. The cochlea diameter ranged from 8.11 to 10.42 mm and correlated negatively with the insertion depth angle. The results suggest that preoperatively measured cochlea diameter combined with the option of different array positions by means of LID may act as predictors for the final insertion depth angle.

  1. Tail-anchored Protein Insertion in Mammals

    PubMed Central

    Cardani, Silvia; Maroli, Annalisa; Vitiello, Adriana; Soffientini, Paolo; Crespi, Arianna; Bram, Richard F.

    2016-01-01

    The GET (guided entry of tail-anchored proteins)/TRC (transmembrane recognition complex) pathway for tail-anchored protein targeting to the endoplasmic reticulum (ER) has been characterized in detail in yeast and is thought to function similarly in mammals, where the orthologue of the central ATPase, Get3, is known as TRC40 or Asna1. Get3/TRC40 function requires an ER receptor, which in yeast consists of the Get1/Get2 heterotetramer and in mammals of the WRB protein (tryptophan-rich basic protein), homologous to yeast Get1, in combination with CAML (calcium-modulating cyclophilin ligand), which is not homologous to Get2. To better characterize the mammalian receptor, we investigated the role of endogenous WRB and CAML in tail-anchored protein insertion as well as their association, concentration, and stoichiometry in rat liver microsomes and cultured cells. Functional proteoliposomes, reconstituted from a microsomal detergent extract, lost their activity when made with an extract depleted of TRC40-associated proteins or of CAML itself, whereas in vitro synthesized CAML and WRB together were sufficient to confer insertion competence to liposomes. CAML was found to be in ∼5-fold excess over WRB, and alteration of this ratio did not inhibit insertion. Depletion of each subunit affected the levels of the other one; in the case of CAML silencing, this effect was attributable to destabilization of the WRB transcript and not of WRB protein itself. These results reveal unanticipated complexity in the mutual regulation of the TRC40 receptor subunits and raise the question as to the role of the excess CAML in the mammalian ER. PMID:27226539

  2. Analytic closed orbit analysis for RHIC insertion

    SciTech Connect

    Lee, S.Y. . Dept. of Physics); Tepikian, S. )

    1991-01-01

    Analytic closed orbit analysis is performed to evaluate the tolerance of quadrupole misalignment and dipole errors (b{sub 0},a{sub 0}) in the RHIC insertion. Sensitivity coefficients of these errors are tabulated for different {beta}{sup 0} values. Using these sensitivity tables, we found that the power supplies ripple of 10{sup {minus}4} can cause closed orbit motion of 0.05 mm at the IP in comparison with the rms beam size of 0.3 mm. It is desirable to have the power supply ripple less than 10{sup {minus}5}. 2 refs., 1 fig., 2 tabs.

  3. Phoenix's Probe Inserted in Martian Soil

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The Phoenix Mars lander's robotic-arm camera took this image of the spacecraft's thermal and electrical-conductivity probe (TECP) inserted into Martian soil on day 149 of the mission. Phoenix landed on Mars' northern plains on May 25, 2008, landing.

    The robotic-arm camera acquired this image at 16:02:41 local solar time. The camera pointing was elevation -72.6986 degrees and azimuth 2.1093 degrees.

    The Phoenix mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  4. Compiler-assisted static checkpoint insertion

    NASA Technical Reports Server (NTRS)

    Long, Junsheng; Fuchs, W. K.; Abraham, Jacob A.

    1992-01-01

    This paper describes a compiler-assisted approach for static checkpoint insertion. Instead of fixing the checkpoint location before program execution, a compiler enhanced polling mechanism is utilized to maintain both the desired checkpoint intervals and reproducible checkpoint 1ocations. The technique has been implemented in a GNU CC compiler for Sun 3 and Sun 4 (Sparc) processors. Experiments demonstrate that the approach provides for stable checkpoint intervals and reproducible checkpoint placements with performance overhead comparable to a previously presented compiler assisted dynamic scheme (CATCH) utilizing the system clock.

  5. Photograph of moon after transearth insertion

    NASA Image and Video Library

    1969-05-24

    AS10-27-3956 (24 May 1969) --- This photograph of the moon was taken after trans-Earth insertion when the Apollo 10 spacecraft was high above the lunar equator near 27 degrees east longitude. North is about 20 degrees left of the top of the photograph. Apollo Landing Site 3 is on the lighted side of the terminator in a dark area just north of the equator. Apollo Landing Site 2 is near the lower left margin of the Sea of Tranquility (Mare Tranquillitatis), which is the large, dark area near the center of the photograph.

  6. New percutaneously inserted spinal fixation system.

    PubMed

    Teitelbaum, George P; Shaolian, Samuel; McDougall, Cameron G; Preul, Mark C; Crawford, Neil R; Sonntag, Volker K H

    2004-03-15

    We describe a new percutaneous minimally invasive spinal fixation system based on pedicle screws and inflatable rods. The rods are inserted in a flexible state and harden following deployment. We test this system in terms of biocompatibility, ferromagnetism, magnetic resonance artifact production, bench top mechanical testing, ease of insertion within cadavers, potential thermal damage to paraspinous muscles in pigs, and long-term device tolerability in sheep. To determine the safety and utility of this system before its use in human subjects. Composite materials and epoxy compounds have been used safely in a variety of implanted medical devices for years with no signs of systemic toxicity or significant device failures. Long-term biocompatibility test of system components was conducted according to International Standards Organization 10993 and Food and Drug Administration Blue Book Memorandum #G95-1 standards. Device components were assessed for magnetic deflection and torque and imaged in a 1.5 Tesla magnetic resonance unit. Full constructs of the system were tested for compression strength, torque, and fatigue per American Society for Testing and Materials F1717 standards. The system was deployed using C-arm fluoroscopic guidance in 11 cadavers and 2 live sheep. Further, the inflatable rods were tested for exothermic damage to paraspinous musculature in 2 pigs. All system components were found to be biocompatible, nonferromagnetic, and produce little magnetic resonance artifact. Compression and torque results for the new system were found to be comparable to standard metallic pedicle screw and rod fixation systems. However, the new system displayed a superior modulus of elasticity relative to standard surgical systems. The new system endured 5 million cycles of repetitive compressions without breakage or significant wear. All cadaver and sheep insertions were performed successfully. Sheep suffered no complications, and minimal blood loss occurred during device

  7. Artists's Conception of Cassini Saturn Orbit Insertion

    NASA Technical Reports Server (NTRS)

    2002-01-01

    This is an artists concept of Cassini during the Saturn Orbit Insertion (SOI) maneuver, just after the main engine has begun firing. The spacecraft is moving out of the plane of the page and to the right (firing to reduce its spacecraft velocity with respect to Saturn) and has just crossed the ring plane.

    The SOI maneuver, which is approximately 90 minutes long, will allow Cassini to be captured by Saturn's gravity into a five-month orbit.Cassini's close proximity to the planet after the maneuver offers a unique opportunity to observe Saturn and its rings at extremely high resolution.

  8. Phoenix's Probe Inserted in Martian Soil

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The Phoenix Mars lander's robotic-arm camera took this image of the spacecraft's thermal and electrical-conductivity probe (TECP) inserted into Martian soil on day 149 of the mission. Phoenix landed on Mars' northern plains on May 25, 2008, landing.

    The robotic-arm camera acquired this image at 16:02:41 local solar time. The camera pointing was elevation -72.6986 degrees and azimuth 2.1093 degrees.

    The Phoenix mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  9. Cassini magnetometer observations during Saturn orbit insertion.

    PubMed

    Dougherty, M K; Achilleos, N; Andre, N; Arridge, C S; Balogh, A; Bertucci, C; Burton, M E; Cowley, S W H; Erdos, G; Giampieri, G; Glassmeier, K-H; Khurana, K K; Leisner, J; Neubauer, F M; Russell, C T; Smith, E J; Southwood, D J; Tsurutani, B T

    2005-02-25

    Cassini's successful orbit insertion has provided the first examination of Saturn's magnetosphere in 23 years, revealing a dynamic plasma and magnetic environment on short and long time scales. There has been no noticeable change in the internal magnetic field, either in its strength or its near-alignment with the rotation axis. However, the external magnetic field is different compared with past spacecraft observations. The current sheet within the magnetosphere is thinner and more extended, and we observed small diamagnetic cavities and ion cyclotron waves of types that were not reported before.

  10. Commercial Generic Bioprocessing Apparatus Science Insert - 03

    NASA Technical Reports Server (NTRS)

    Moreno, Nancy; Stodieck, Louis; Cushing, Paula; Stowe, Mark; Hamilton, Mary Ann; Werner, Ken

    2008-01-01

    Commercial Generic Bioprocessing Apparatus Science Insert - 03 (CSI-03) is the third set of investigations in the CSI program series. The CSI program provides the K-12 community opportunities to utilize the unique microgravity environment of the International Space Station as part of the regular classroom to encourage learning and interest in science, technology, engineering and math. CSI-03 will examine the complete life cycle of the painted lady butterfly and the ability of an orb weaving spider to spin a web, eat and remain healthy in space.

  11. 21 CFR 529.1940 - Progesterone intravaginal inserts.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Progesterone intravaginal inserts. 529.1940... Progesterone intravaginal inserts. (a) Specifications. Each insert contains: (1) 1.38 grams (g) progesterone in molded silicone over a nylon spine. (2) 0.3 g progesterone in molded silicone over a flexible nylon spine...

  12. 21 CFR 529.1940 - Progesterone intravaginal inserts.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Progesterone intravaginal inserts. 529.1940... Progesterone intravaginal inserts. (a) Specifications. Each insert contains: (1) 1.38 grams (g) progesterone in molded silicone over a nylon spine. (2) 0.3 g progesterone in molded silicone over a flexible nylon spine...

  13. 21 CFR 529.1940 - Progesterone intravaginal inserts.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Progesterone intravaginal inserts. 529.1940... Progesterone intravaginal inserts. (a) Specifications. Each insert contains: (1) 1.38 grams (g) progesterone in molded silicone over a nylon spine. (2) 0.3 g progesterone in molded silicone over a flexible nylon spine...

  14. 21 CFR 529.1940 - Progesterone intravaginal inserts.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Progesterone intravaginal inserts. 529.1940... Progesterone intravaginal inserts. (a) Specifications. Each insert contains: (1) 1.38 grams (g) progesterone in molded silicone over a nylon spine. (2) 0.3 g progesterone in molded silicone over a flexible nylon spine...

  15. 21 CFR 529.1940 - Progesterone intravaginal inserts.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Progesterone intravaginal inserts. 529.1940... Progesterone intravaginal inserts. (a) Specifications. Each insert contains: (1) 1.38 grams (g) progesterone in molded silicone over a nylon spine. (2) 0.3 g progesterone in molded silicone over a flexible nylon spine...

  16. T-tube insertion for sclerotic subglottic stenosis.

    PubMed

    Goto, Taichiro; Kato, Ryoichi

    2014-02-01

    T-tube insertion is effective treatment for subglottic stenosis, but it is generally difficult due to bending of the T-tube. In a 52-year-old woman with relapsing polychondritis, a T-tube was inserted after predilatation using Hegar dilators. We describe the details of our T-tube insertion methods for sclerotic subglottic stenosis.

  17. 21 CFR 310.515 - Patient package inserts for estrogens.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Patient package inserts for estrogens. 310.515... package inserts for estrogens. (a) Requirement for a patient package insert. FDA concludes that the safe and effective use of drug products containing estrogens requires that patients be fully informed of...

  18. Quench Module Insert (QMI) and the Diffusion Module Insert (DMI) Furnace Development

    NASA Technical Reports Server (NTRS)

    Crouch, Myscha R.; Carswell, William E.; Farmer, Jeff; Rose, Fred; Tidwell, Paul H., II

    2000-01-01

    The Quench Module Insert (QMI) and the Diffusion Module Insert (DMI) are microgravity furnaces under development at Marshall Space Flight Center. The furnaces are being developed for the first Materials Science Research Rack (MSRR-1) of the Materials Science Research Facility (MSRF), one of the first International Space Station (ISS) scientific payloads. QMI is a Bridgman furnace with quench capability for studying interface behavior during directional solidification of metallic and alloy materials. DMI will be a Bridgman-Stockbarger furnace to study diffusion processes in semiconductors. The design for each insert, both QMI and DMI, is driven by specific science, operations and safety requirements, as well as by constraints arising from resource limitations, such as volume, mass and power. Preliminary QMI analysis and testing indicates that the design meets these requirements.

  19. Insertion torque versus mechanical resistance of mini-implants inserted in different cortical thickness

    PubMed Central

    Santos, Renata de Faria; Ruellas, Antonio Carlos de Oliveira; Fernandes, Daniel Jogaib; Elias, Carlos Nelson

    2014-01-01

    Objective This study aimed to measure insertion torque, tip mechanical resistance to fracture and transmucosal neck of mini-implants (MI) (Conexão Sistemas de PróteseT), as well as to analyze surface morphology. Methods Mechanical tests were carried out to measure the insertion torque of MIs in different cortical thicknesses, and tip mechanical resistance to fracture as well as transmucosal neck of MIs. Surface morphology was assessed by scanning electron microscopy (SEM) before and after the mechanical tests. Results Values of mechanical resistance to fracture (22.14 N.cm and 54.95 N.cm) were higher and statistically different (P < 0.05) from values of insertion torque for 1-mm (7.60 N.cm) and 2-mm (13.27 N.cm) cortical thicknesses. Insertion torque was statistically similar (P > 0.05) to torsional fracture in the tip of MI (22.14 N.cm) when 3 mm cortical thickness (16.11 N.cm) and dense bone (23.95 N.cm) were used. Torsional fracture of the transmucosal neck (54.95 N.cm) was higher and statistically different (P < 0.05) from insertion torsional strength in all tested situations. SEM analysis showed that the MIs had the same smooth surface when received from the manufacturer and after the mechanical tests were performed. Additionally, no significant marks resulting from the manufacturing process were observed. Conclusion All mini-implants tested presented adequate surface morphology. The resistance of mini-implants to fracture safely allows placement in 1 and 2-mm cortical thickness. However, in 3-mm cortical thickness and dense bones, pre-drilling with a bur is recommended before insertion. PMID:25162571

  20. Lithium Insertion Chemistry of Some Iron Vanadates

    SciTech Connect

    Patoux, Sebastien; Richardson, Thomas J.

    2007-02-02

    Lithium insertion into various iron vanadates has been investigated. Fe{sub 2}V{sub 4}O{sub 13} and Fe{sub 4}(V{sub 2}O{sub 7}){sub 3} {center_dot} 3H{sub 2}O have discharge capacities approaching 200 mAh/g above 2.0 V vs. Li{sup +}/Li. Although the potential profiles change significantly between the first and subsequent discharges, capacity retention is unexpectedly good. Other phases, structurally related to FeVO{sub 4}, containing copper and/or sodium ions were also studied. One of these, {beta}-Cu{sub 3}Fe{sub 4}(VO{sub 4}){sub 6}, reversibly consumes almost 10 moles of electrons per formula unit (ca. 240 mAh g{sup -1}) between 3.6 and 2.0 V vs. Li{sup +}/Li, in a non-classical insertion process. It is proposed that both copper and vanadium are electrochemically active, whereas iron(III) reacts to form LiFe{sup III}O{sub 2}. The capacity of the Cu{sub 3}Fe{sub 4}(VO{sub 4}){sub 6}/Li system is nearly independent of cycling rate, stabilizing after a few cycles at 120-140 mAh g{sup -1}. Iron vanadates exhibit better capacities than their phosphate analogues, whereas the latter display more constant discharge potentials.

  1. Model of a Hollow Cathode Insert Plasma

    NASA Technical Reports Server (NTRS)

    Mikellides, Ioannis G.; Katz, Ira; Goebel, Dan M.; Polk, James E.

    2004-01-01

    A 2-D axisymmetric fluid model of the plasma in the insert region of a hollow cathode is presented. The level of sophistication included in the model is motivated in part by the need to determine quantitatively plasma fluxes to the emitter surface. The ultimate goal is to assess whether plasma effects can degrade the life of impregnated inserts beyond those documented throughout the 30-50 year history of vacuum cathode technologies. Results from simulations of a 1.2-cm diameter cathode operating at a discharge current of 25 A, and a gas flow rate of 5 sccm, suggest that approximately 10 A of electron current, and 3.5 A of ion current return to the emitter surface. The total emitted electron current computed by the model is about 35 A. Comparisons with plasma measurements suggest that anomalous heating of the plasma due to two-stream instabilities is possible near the orifice region. Solution to the heavy species energy equation, with classical transport and no viscous effects, predicts heavy species temperatures as high as 2640 K.

  2. Phoenix Conductivity Probe Inserted in Martian Soil

    NASA Technical Reports Server (NTRS)

    2008-01-01

    This series of six images from the Robotic Arm Camera on NASA's Phoenix Mars Lander records the first time that the four spikes of the lander's thermal and electrical conductivity probe were inserted into Martian soil.

    The images were taken on July 8, 2008, during the Phoenix mission's 43rd Martian day, or sol, since landing. The insertion visible from the shadows cast on the ground on that sol was a validation test of the procedure. The spikes on the probe are about 1.5 centimeters or half an inch long.

    The science team will use the probe tool to assess how easily heat and electricity move through the soil from one spike to another. Such measurements can provide information about frozen or unfrozen water in the soil. The probe is mounted on the 'knuckle' of Phoenix's Robotic Arm. It has already been used for assessing water vapor in the atmosphere when it is held above the ground.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is led by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  3. Cell line fingerprinting using retroelement insertion polymorphism.

    PubMed

    Ustyugova, Svetlana V; Amosova, Anna L; Lebedev, Yuri B; Sverdlov, Eugene D

    2005-04-01

    Human cell lines are an indispensable tool for functional studies of living entities in their numerous manifestations starting with integral complex systems such as signal pathways and networks, regulation of gene ensembles, epigenetic factors, and finishing with pathological changes and impact of artificially introduced elements, such as various transgenes, on the behavior of the cell. Therefore, it is highly desirable to have reliable cell line identification techniques to make sure that the cell lines to be used in experiments are exactly what is expected. To this end, we developed a set of informative markers based on insertion polymorphism of human retroelements (REs). The set includes 47 pairs of PCR primers corresponding to introns of the human genes with dimorphic LINE1 (L1) and Alu insertions. Using locus-specific PCR assays, we have genotyped 10 human cell lines of various origins. For each of these cell lines, characteristic fingerprints were obtained. An estimated probability that two different cell lines possess the same marker genotype is about 10-18. Therefore, the proposed set of markers provides a reliable tool for cell line identification.

  4. Radiological Insertion and Management of Peritoneovenous Shunt

    SciTech Connect

    Bratby, M. J.; Hussain, F. F. Lopez, A. J.

    2007-06-15

    The purpose of the study was to report our experience of the management of complications following the insertion of a peritoneovenous shunt for intractable malignant ascites. From June 1999 to January 2006, 26 patients underwent insertion of a peritoneovenous shunt for ascites by interventional radiologists. We have used ultrasound and shuntography to assist in the diagnosis of the cause of shunt blockage. Successful techniques for the restoration of the shunt function include port- pumping, stripping of any fibrin sheath, and revision of either the venous or peritoneal catheter. The procedure was initially successful in all patients with continued patency until death in 17. A further four patients are still alive with a functioning shunt. There was one rapid postprocedure death resulting from pulmonary edema. Two patients developed pneumothorax, managed successfully with either a chest drain or aspiration. Shunt dysfunction occurred eight times in seven patients. There were five successful revisions in four patients. Overall, shunt patency has been maintained in 80.1% of patients. Shunt dysfunction is seen in a significant number of patients, but successful revision of the shunt can be achieved in the majority.

  5. Mammalian NUMT insertion is non-random

    PubMed Central

    Tsuji, Junko; Frith, Martin C.; Tomii, Kentaro; Horton, Paul

    2012-01-01

    It is well known that remnants of partial or whole copies of mitochondrial DNA, known as Nuclear MiTochondrial sequences (NUMTs), are found in nuclear genomes. Since whole genome sequences have become available, many bioinformatics studies have identified putative NUMTs and from those attempted to infer the factors involved in NUMT creation. These studies conclude that NUMTs represent randomly chosen regions of the mitochondrial genome. There is less consensus regarding the nuclear insertion sites of NUMTs — previous studies have discussed the possible role of retrotransposons, but some recent ones have reported no correlation or even anti-correlation between NUMT sites and retrotransposons. These studies have generally defined NUMT sites using BLAST with default parameters. We analyze a redefined set of human NUMTs, computed with a carefully considered protocol. We discover that the inferred insertion points of NUMTs have a strong tendency to have high-predicted DNA curvature, occur in experimentally defined open chromatin regions and often occur immediately adjacent to A + T oligomers. We also show clear evidence that their flanking regions are indeed rich in retrotransposons. Finally we show that parts of the mitochondrial genome D-loop are under-represented as a source of NUMTs in primate evolution. PMID:22761406

  6. Model of a Hollow Cathode Insert Plasma

    NASA Technical Reports Server (NTRS)

    Mikellides, Ioannis G.; Katz, Ira; Goebel, Dan M.; Polk, James E.

    2004-01-01

    A 2-D axisymmetric fluid model of the plasma in the insert region of a hollow cathode is presented. The level of sophistication included in the model is motivated in part by the need to determine quantitatively plasma fluxes to the emitter surface. The ultimate goal is to assess whether plasma effects can degrade the life of impregnated inserts beyond those documented throughout the 30-50 year history of vacuum cathode technologies. Results from simulations of a 1.2-cm diameter cathode operating at a discharge current of 25 A, and a gas flow rate of 5 sccm, suggest that approximately 10 A of electron current, and 3.5 A of ion current return to the emitter surface. The total emitted electron current computed by the model is about 35 A. Comparisons with plasma measurements suggest that anomalous heating of the plasma due to two-stream instabilities is possible near the orifice region. Solution to the heavy species energy equation, with classical transport and no viscous effects, predicts heavy species temperatures as high as 2640 K.

  7. Insertional mutagenesis and illegitimate recombination in mycobacteria.

    PubMed Central

    Kalpana, G V; Bloom, B R; Jacobs, W R

    1991-01-01

    Mycobacteria, particularly Mycobacterium tuberculosis, Mycobacterium leprae, and Mycobacterium avium, are major pathogens of man. Although insertional mutagenesis has been an invaluable genetic tool for analyzing the mechanisms of microbial pathogenesis, it has not yet been possible to apply it to the mycobacteria. To overcome intrinsic difficulties in directly manipulating the genetics of slow-growing mycobacteria, including M. tuberculosis and bacille Calmette-Guérin (BCG) vaccine strains, we developed a system for random shuttle mutagenesis. A genomic library of Mycobacterium smegmatis was subjected to transposon mutagenesis with Tn5 seq1, a derivative of Tn5, in Escherichia coli and these transposon-containing recombinant plasmids were reintroduced into mycobacterial chromosomes by homologous recombination. This system has allowed us to isolate several random auxotrophic mutants of M. smegmatis. To extend this strategy to M. tuberculosis and BCG, targeted mutagenesis was performed using a cloned BCG methionine gene that was subjected to Tn5 seq1 mutagenesis in E. coli and reintroduced into the mycobacteria. Surprisingly for prokaryotes, both BCG and M. tuberculosis were found to incorporate linear DNA fragments into illegitimate sites throughout the mycobacterial genomes at a frequency of 10(-5) to 10(-4) relative to the number of transformants obtained with autonomously replicating vectors. Thus the efficient illegitimate recombination of linear DNA fragments provides the basis for an insertional mutagenesis system for M. tuberculosis and BCG. Images PMID:2052623

  8. Horizontally separated 1-in-1 crossing insertions

    SciTech Connect

    Syphers, M.J.

    1985-10-01

    Previous to this workshop, realistic lattices have been developed for vertically separated l-in-l (e.g., D.E. Johnson, A.A. Garren) and 2-in-1 (e.g., S. Heifets) magnets as well as for horizontally separated 2-in-l magnets (e.g., SSC RDS). Bringing together the widely separated ({approximately}60-70 cm) beams in a reasonable length of tunnel and keeping the dispersion zero at the interaction point has been difficult in the vertical l-in-l case. Most designs have required spacial 2-in-1 quadrupoles near the interaction point where the beams are separated by 15 cm or less. It is not clear that such magnets, as dictated by some of these lattice designs, can easily be built. The purpose of this exercise is to provide a crossing insertion for a realistic lattice which involves horizontally separated l-in-l magnets. The following horizontal crossing insertions, which incorporate the dispersion suppressors and phase trombones into the major arcs, need no special 2-in-1 magnets near the interaction point. The dispersion at the IP created by the horizontal crossing can be cancelled by the dispersion suppressor and one set of triplets.

  9. Insertion of coherence requests for debugging a multiprocessor

    DOEpatents

    Blumrich, Matthias A.; Salapura, Valentina

    2010-02-23

    A method and system are disclosed to insert coherence events in a multiprocessor computer system, and to present those coherence events to the processors of the multiprocessor computer system for analysis and debugging purposes. The coherence events are inserted in the computer system by adding one or more special insert registers. By writing into the insert registers, coherence events are inserted in the multiprocessor system as if they were generated by the normal coherence protocol. Once these coherence events are processed, the processing of coherence events can continue in the normal operation mode.

  10. Recessed impingement insert metering plate for gas turbine nozzles

    DOEpatents

    Itzel, Gary Michael; Burdgick, Steven Sebastian

    2002-01-01

    An impingement insert sleeve is provided that is adapted to be disposed in a coolant cavity defined through a stator vane. The insert has a generally open inlet end and first and second diametrically opposed, perforated side walls. A metering plate having at least one opening defined therethrough for coolant flow is mounted to the side walls to generally transverse a longitudinal axis of the insert, and is disposed downstream from said inlet end. The metering plate improves flow distribution while reducing ballooning stresses within the insert and allowing for a more flexible insert attachment.

  11. Assessment of a simplified insertion technique for intrauterine devices.

    PubMed

    Christenson, Kamilee; Lerma, Klaira; Shaw, Kate A; Blumenthal, Paul D

    2016-07-01

    To explore a simplified technique for intrauterine device (IUD) insertion. The present prospective longitudinal study enrolled patients aged at least 18years presenting at the gynecology clinic of Stanford University for IUD insertion between June 1, 2013 and June 30, 2014. No pelvic examination or uterine sounding was performed prior to IUD insertion. Transvaginal ultrasonography was performed immediately after insertion and at 4-6weeks to confirm device placement. The primary outcome was successful IUD placement. The study enrolled 50 patients. IUD insertion was completed successfully without any cervical manipulation in 40 (80%) participants. Sounding was not needed for any procedures. A cervical dilator was required to locate the internal os for 10 (20%) patients. The mean distance between IUDs and the endometrial verge immediately following insertion was 2.9mm. IUD insertion was rated "difficult" by the physician performing the procedure in 3 (6%) patients. No perforations were recorded. IUD expulsion occurred in 3 (6%) patients; menorrhagia was the indication for IUD insertion in two of these patients. IUD insertion without prior pelvic examination and sounding was feasible; this technique could reduce the need for instrument use during insertion and, consequently, the pain associated with insertion. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  12. Method Of Wire Insertion For Electric Machine Stators

    DOEpatents

    Brown, David L; Stabel, Gerald R; Lawrence, Robert Anthony

    2005-02-08

    A method of inserting coils in slots of a stator is provided. The method includes interleaving a first set of first phase windings and a first set of second phase windings on an insertion tool. The method also includes activating the insertion tool to radially insert the first set of first phase windings and the first set of second phase windings in the slots of the stator. In one embodiment, interleaving the first set of first phase windings and the first set of second phase windings on the insertion tool includes forming the first set of first phase windings in first phase openings defined in the insertion tool, and forming the first set of second phase windings in second phase openings defined in the insertion tool.

  13. [Drug package inserts and the adequacy of patient's drug information].

    PubMed

    da Silva, T; Dal-Pizzol, F; Bello, C M; Mengue, S S; Schenkel, E P

    2000-04-01

    To investigate the adequacy of the content and format of the patient information section in package inserts of commonly prescribed drugs at the internal medicine service of a school hospital. Forty eight package inserts were collected from six pharmacies of the city of Porto Alegre in June 1998. The presence of mandatory notification and other information required by Brazilian laws that regulate inserts content was examined. No one package inserts contained all the notification required by law. Warnings about medication storage and expiration date were the most frequently information found in package inserts analyzed. Important information for the drug user was not presented in package inserts analyzed, limiting the purpose of inserts as an instrument for patient education.

  14. Non-insertional tendinopathy of the subscapularis.

    PubMed

    Dierckman, Brian D; Shah, Nirav R; Larose, Connor R; Gerbrandt, Stacey; Getelman, Mark H

    2013-07-01

    (1) Describe a previously unreported finding involving the intra-articular portion of the subscapularis, the Conrad lesion. (2) Describe a novel classification system for the spectrum of non-insertional tendinopathy of the subscapularis. (3) Report the outcomes of surgical treatment of this spectrum of pathology. Outcomes of 34 patients (23 males and 11 females, mean age 60.5 ± 7.5) with non-insertional tendinopathy of the subscapularis treated arthroscopically were retrospectively reviewed. All patients had anterior shoulder pain with no weakness during belly-press testing and no subscapularis footprint involvement on magnetic resonance imaging. All patients were managed with subscapularis tendon debridement and side-to-side repair along with treatment of concomitant pathology. Seven patients had a Type I lesion (so-called Conrad lesion) - a nodule on the leading edge of the subscapularis. Eighteen patients had a Type II lesion - a visible split tear with degeneration in the upper ½ of the intra-articular tendon. Nine patients had a Type III lesion - more extensive splitting in the tendon with advanced tendon degeneration. At a mean follow-up of 24 months, 97% of patients were completely satisfied. Significant improvements were seen in forward elevation (152 ± 12° to 172 ± 5°, P < 0.001) and visual analog scale pain scores (5.9 ± 1.7-0.6 ± 1.0, P < 0.001). Internal rotation strength and external rotation motion at the side were maintained. ASES scores averaged 95.4 ± 7.4, disabilities of arm, shoulder and hand scores averaged 6.19 ± 9.8, Western Ontario Rotator Cuff scores averaged 91.7 ± 9.3 and the average University of California at Los Angeles score was 33.1 ± 2.4. We present a previously unreported finding of the subscapularis, the Conrad lesion, along with a novel classification system for non-insertional tendinopathy of the subscapularis. Arthroscopic treatment of this spectrum of tendinopathy along with concomitant shoulder pathology eliminated

  15. Intermetallic insertion anodes for lithium batteries.

    SciTech Connect

    Thackeray, M. M.; Vaughey, J.; Johnson, C. S.; Kepler, K. D.

    1999-11-12

    Binary intermetallic compounds containing lithium, or lithium alloys, such as Li{sub x}Al, Li{sub x}Si and Li{sub x}Sn have been investigated in detail in the past as negative electrode materials for rechargeable lithium batteries. It is generally acknowledged that the major limitation of these systems is the large volumetric expansion that occurs when lithium reacts with the host metal. Such large increases in volume limit the practical use of lithium-tin electrodes in electrochemical cells. It is generally recognized that metal oxide electrodes, MO{sub y}, in lithium-ion cells operate during charge and discharge by means of a reversible lithium insertion/extraction process, and that the cells offer excellent cycling behavior when the crystallographic changes to the unit cell parameters and unit cell volume of the Li{sub x}MO{sub y} electrode are kept to a minimum. An excellent example of such an electrode is the spinel Li{sub 4}Ti{sub 5}O{sub 12}, which maintains its cubic symmetry without any significant change to the lattice parameter (and hence unit cell volume) during lithium insertion to the rock-salt composition Li{sub 7}Ti{sub 5}O{sub 12}. This spinel electrode is an example of a ternary Li{sub x}MO{sub y} system in which a binary MO{sub y} framework provides a stable host structure for lithium. With this approach, the authors have turned their attention to exploring ternary intermetallic systems Li{sub x}MM{prime} in the hope of finding a system that is not subject to the high volumetric expansion that typifies many binary systems. In this paper, the authors present recent data of their investigations of lithium-copper-tin and lithium-indium-antimonide electrodes in lithium cells. The data show that lithium can be inserted reversibly into selected intermetallic compounds with relatively small expansion of the lithiated intermetallic structures.

  16. Polymorphic Alu insertions among Mayan populations.

    PubMed

    Herrera, R J; Rojas, D P; Terreros, M C

    2007-01-01

    The Mayan homeland within Mesoamerica spans five countries: Belize, El Salvador, Guatemala, Honduras and Mexico. There are indications that the people we call the Maya migrated from the north to the highlands of Guatemala as early as 4000 B.C. Their existence was village-based and agricultural. The culture of these Preclassic Mayans owes much to the earlier Olmec civilization, which flourished in the southern portion of North America. In this study, four different Mayan groups were examined to assess their genetic variability. Ten polymorphic Alu insertion (PAI) loci were employed to ascertain the genetic affinities among these Mayan groups. North American, African, European and Asian populations were also examined as reference populations. Our results suggest that the Mayan groups examined in this study are not genetically homogeneous.

  17. INSERTION DEVICE UPGRADE PLANS AT THE NSLS.

    SciTech Connect

    TANABE, T.; BLEDNYKH, A.; HARDER, D.; LEHECKA, M.; RAKOWSKY, G.; SKARITKA, J.

    2005-05-16

    This paper describes plans to upgrade insertion devices (IDs) at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, U.S.A. The aging wiggler (W120) at X25 is being replaced by a 1 m long in-vacuum mini-gap undulator (MGU-X25) optimized for a dedicated macromolecular crystallography program. A new, 1/3 m long, undulator (MGU or SCU-X9), will be installed between a pair of RF cavities at X9, and will serve a new beamline dedicated for small angle x-ray scattering (SAXS). Both IDs will have provision for cryocooling the NdFeB hybrid arrays to 150K to raise the field and K-value and to obtain better spectral coverage. Design issues of the devices and other considerations, especially magnetic measurement at low temperature, will be discussed.

  18. [Inserts and shoes for foot deformities].

    PubMed

    Hien, N M

    2003-02-01

    Prevention of habitual or shoe-induced foot and toe deformities in children and treatment of congenital or developing malformations require a change of view towards functional aspects and the use of modern technical possibilities based on our traditional knowledge.Statics, functional anatomy, biomechanics, neuromotor and psychomotor activity, and developmental physiology have to be considered as well as the broad variety of physiological interindividual differences. Modern materials and fabrication techniques make it easier to produce anatomically and functionally correct and appealing shoes, inserts, and orthoses. New means of invasive treatment improve the preconditions for orthotic management. Cultural and cosmetic expectations and the real extent of disability, impairment, and handicap have to be carefully differentiated for the sake of every single child.

  19. How to insert a peripheral cannula.

    PubMed

    Shaw, Sally Jane

    2016-11-16

    Rationale and key points This article aims to assist practitioners to undertake the safe and effective insertion of a peripheral cannula. It provides information on best practice related to peripheral cannulation with an open-ported safety cannula. The same principles for practice apply to non-ported open safety cannulae. » Peripheral cannulation enables venous access, the administration of intravenous medication, infusion therapy and total parenteral nutrition. It also enables blood samples to be obtained. » Peripheral cannulation is a common procedure that requires high standards of care and management to optimise patient outcomes. Reflective activity 'How to' articles can help update your practice and ensure it remains evidence-based. Apply this article to your practice. Reflect on and write a short account of: » How you think this article has changed your practice when performing peripheral cannulation. » How you could use this resource to assist with supporting colleagues.

  20. Impact of Orthodontic Decompensation on Bone Insertion

    PubMed Central

    Guedes, Fabio Pinto; Capelozza Filho, Leopoldino; Garib, Daniela Gamba; Nary Filho, Hugo; Borgo, Evandro José; Cardoso, Mauricio de Almeida

    2014-01-01

    There has always been concern in determining the relationship between orthodontic tooth movement and the consequent biological costs to the periodontium and tooth root. The possibility of evaluating the tooth and bone morphology by CBCT allows more accurate analysis of qualitative and quantitative aspects of these processes. This paper presents a case report of a 20-year-old male patient with Class III malocclusion and hyperdivergent facial pattern, who was surgically treated. A significant amount of labial movement of mandibular incisors was performed during orthodontic treatment before surgery. CBCT was used for evaluation of buccal and lingual bone plates before and after tooth decompensation. The changes in the bone insertion level of maxillary and mandibular incisors in the present case encourage a reflection on the treatment protocol in individuals with dentoskeletal discrepancies. PMID:25436157

  1. Inter-aural attenuation with insert earphones.

    PubMed

    Munro, Kevin J; Contractor, Alia

    2010-10-01

    The aim of the present study was to determine inter-aural attenuation (IA) values for pure tones and a broadband click obtained using an ER-3A insert earphone with a foam plug and with a customized hard acrylic earmould. Participants were 15 adults with a longstanding unilateral dead ear. IA was operationally defined as the difference between the good-ear and poorer-ear not-masked air conduction threshold. Minimum IA values for the foam earplug were 50 dB and 55 dB for pure tones and broadband click, respectively. Minimum IA values for the hard acrylic earmould were 45 dB and 50 dB for pure tones and broadband click, respectively.

  2. Effect of the Starting Point of Half-Pin Insertion on the Insertional Torque of the Pin at the Tibia

    PubMed Central

    Kim, Sung-Jae; Kim, Sung-Hwan; Kim, Young-Hwan

    2015-01-01

    Purpose The authors have observed a failure to achieve secure fixation in elderly patients when inserting a half-pin at the anteromedial surface of the tibia. The purpose of this study was to compare two methods for inserting a half-pin at tibia diaphysis in elderly patients. Materials and Methods Twenty cadaveric tibias were divided into Group C or V. A half-pin was inserted into the tibias of Group C via the conventional method, from the anteromedial surface to the interosseous border of the tibia diaphysis, and into the tibias of Group V via the vertical method, from the anterior border to the posterior surface at the same level. The maximum insertion torque was measured during the bicortical insertion with a torque driver. The thickness of the cortex was measured by micro-computed tomography. The relationship between the thickness of the cortex engaged and the insertion torque was investigated. Results The maximum insertion torque and the thickness of the cortex were significantly higher in Group V than Group C. Both groups exhibited a statistically significant linear correlation between torque and thickness by Spearman's rank correlation analysis. Conclusion Half-pins inserted by the vertical method achieved purchase of more cortex than those inserted by the conventional method. Considering that cortical thickness and insertion torque in Group V were significantly greater than those in Group C, we suggest that the vertical method of half-pin insertion may be an alternative to the conventional method in elderly patients. PMID:25510759

  3. Regulatory perspective on incomplete control rod insertions

    SciTech Connect

    Chatterton, M.

    1997-01-01

    The incomplete control rod insertions experienced at South Texas Unit 1 and Wolf Creek are of safety concern to the NRC staff because they represent potential precursors to loss of shutdown margin. Even before it was determined if these events were caused by the control rods or by the fuel there was an apparent correlation of the problem with high burnup fuel. It was determined that there was also a correlation between high burnup and high drag forces as well as with rod drop time histories and lack of rod recoil. The NRC staff initial actions were aimed at getting a perspective on the magnitude of the problem as far as the number of plants and the amount of fuel that could be involved, as well as the safety significance in terms of shutdown margin. As tests have been performed and data has been analyzed the focus has shifted more toward understanding the problem and the ways to eliminate it. At this time the staff`s understanding of the phenomena is that it was a combination of factors including burnup, power history and temperature. The problem appears to be very sensitive to these factors, the interaction of which is not clearly understood. The model developed by Westinghouse provides a possible explanation but there is not sufficient data to establish confidence levels and sensitivity studies involving the key parameters have not been done. While several fixes to the problem have been discussed, no definitive fixes have been proposed. Without complete understanding of the phenomena, or fixes that clearly eliminate the problem the safety concern remains. The safety significance depends on the amount of shutdown margin lost due to incomplete insertion of the control rods. Were the control rods to stick high in the core, the reactor could not be shutdown by the control rods and other means such as emergency boration would be required.

  4. Insertion of intrauterine contraceptive devices by registered nurses in Australia.

    PubMed

    Kemeny, Fiona; Digiusto, Erol; Bateson, Deborah

    2016-02-01

    In spite of many advantages, intrauterine contraception (IUC) is underutilised in Australia: only 5% of Australian women using contraceptive methods in 2011 were using IUC. In 2012, Family Planning New South Wales (FPNSW) commenced training registered nurses (RNs) to insert IUC. This article reports outcomes of insertion attempts by the first four trained RNs and suggests strategies for increasing IUC utilisation in Australia. Data regarding client characteristics and outcomes of insertion attempts, including relevant adverse events that occurred during a 6-month follow-up period after the IUC insertions, were retrospectively extracted from the FPNSW clinical record system and analysed in SPSS. Of 207 insertion attempts by RNs, 91% were successful without Medical Officer (MO) assistance. The likelihood of insertion attempts being successful did not differ significantly between nulliparous and parous clients. Incidence of a postinsertion adverse event was equal to or less than rates in previous studies. All adverse events involved parous clients. We have shown that RNs who undertook competency-based IUC insertion training had a high rate of successful insertions and a low rate of adverse outcomes. Utilisation of IUC in Australia could be increased by engaging RNs as inserters, and it is timely to review the barriers that make it difficult for private medical services to employ RNs to insert IUC. © 2015 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  5. Detecting Statistically Significant Common Insertion Sites in Retroviral Insertional Mutagenesis Screens

    PubMed Central

    de Ridder, Jeroen; Uren, Anthony; Kool, Jaap; Reinders, Marcel; Wessels, Lodewyk

    2006-01-01

    Retroviral insertional mutagenesis screens, which identify genes involved in tumor development in mice, have yielded a substantial number of retroviral integration sites, and this number is expected to grow substantially due to the introduction of high-throughput screening techniques. The data of various retroviral insertional mutagenesis screens are compiled in the publicly available Retroviral Tagged Cancer Gene Database (RTCGD). Integrally analyzing these screens for the presence of common insertion sites (CISs, i.e., regions in the genome that have been hit by viral insertions in multiple independent tumors significantly more than expected by chance) requires an approach that corrects for the increased probability of finding false CISs as the amount of available data increases. Moreover, significance estimates of CISs should be established taking into account both the noise, arising from the random nature of the insertion process, as well as the bias, stemming from preferential insertion sites present in the genome and the data retrieval methodology. We introduce a framework, the kernel convolution (KC) framework, to find CISs in a noisy and biased environment using a predefined significance level while controlling the family-wise error (FWE) (the probability of detecting false CISs). Where previous methods use one, two, or three predetermined fixed scales, our method is capable of operating at any biologically relevant scale. This creates the possibility to analyze the CISs in a scale space by varying the width of the CISs, providing new insights in the behavior of CISs across multiple scales. Our method also features the possibility of including models for background bias. Using simulated data, we evaluate the KC framework using three kernel functions, the Gaussian, triangular, and rectangular kernel function. We applied the Gaussian KC to the data from the combined set of screens in the RTCGD and found that 53% of the CISs do not reach the significance

  6. Immediate post-partum insertion of intrauterine devices.

    PubMed

    Grimes, David A; Lopez, Laureen M; Schulz, Kenneth F; Van Vliet, Huib Aam; Stanwood, Nancy L

    2010-05-12

    Insertion of an intrauterine device (IUD) immediately after delivery is appealing for several reasons. The woman is known not to be pregnant, her motivation for contraception may be high, and the setting may be convenient for both the woman and her provider. However, the risk of spontaneous expulsion may be unacceptably high. To assess the efficacy and feasibility of IUD insertion immediately after expulsion of the placenta. Our a priori hypothesis was that this practice is safe but associated with higher expulsion rates than interval IUD insertion. We searched MEDLINE, CENTRAL, POPLINE, EMBASE, ClinicalTrials.gov, and ICTRP. We also contacted investigators to identify other trials. We sought all randomized controlled trials (RCTs) with at least one treatment arm that involved immediate post-partum (within 10 minutes of placental expulsion) insertion of an IUD. Comparisons could include different IUDs, different insertion techniques, immediate versus delayed post-partum insertion, or immediate versus interval insertion (unrelated to pregnancy). Studies could include either vaginal or cesarean deliveries. We evaluated the methodological quality of each report and sought to identify duplicate reporting of data from multicenter trials. Two authors abstracted the data. Principal outcome measures were pregnancy, expulsion, and continuation rates. Because the trials did not have uniform interventions, we were unable to aggregate them in a meta-analysis. We found nine RCTs; one directly compared immediate post-partum insertion with delayed insertion. Expulsion by six months was more likely for the immediate group than the delayed insertion group (OR 6.77; 95% CI 1.43 to 32.14). In trials of immediate insertion alone, modifications of existing devices, such as adding absorbable sutures or additional appendages, did not appear beneficial. Most studies showed no important differences between insertions done by hand or by instruments. Lippes Loop and Progestasert devices did

  7. Submission of the first full scale prototype chip for upgraded ATLAS pixel detector at LHC, FE-I4A

    NASA Astrophysics Data System (ADS)

    Barbero, Marlon; Arutinov, David; Beccherle, Roberto; Darbo, Giovanni; Dube, Sourabh; Elledge, David; Fleury, Julien; Fougeron, Denis; Garcia-Sciveres, Maurice; Gensolen, Fabrice; Gnani, Dario; Gromov, Vladimir; Jensen, Frank; Hemperek, Tomasz; Karagounis, Michael; Kluit, Ruud; Kruth, Andre; Mekkaoui, Abderrezak; Menouni, Mohsine; Schipper, Jan David; Wermes, Norbert; Zivkovic, Vladimir

    2011-09-01

    A new ATLAS pixel chip FE-I4 is being developed for use in upgraded LHC luminosity environments, including the near-term Insertable B-Layer (IBL) upgrade. FE-I4 is designed in a 130 nm CMOS technology, presenting advantages in terms of radiation tolerance and digital logic density compared to the 0.25 μm CMOS technology used for the current ATLAS pixel IC, FE-I3. The FE-I4 architecture is based on an array of 80×336 pixels, each 50×250 μm2, consisting of analog and digital sections. In the summer 2010, a first full scale prototype FE-I4A was submitted for an engineering run. This IC features the full scale pixel array as well as the complex periphery of the future full-size FE-I4. The FE-I4A contains also various extra test features which should prove very useful for the chip characterization, but deviate from the needs for standard operation of the final FE-I4 for IBL. In this paper, focus will be brought to the various features implemented in the FE-I4A submission, while also underlining the main differences between the FE-I4A IC and the final FE-I4 as envisioned for IBL.

  8. Neonatal peripherally inserted central catheters: recommendations for prevention of insertion and postinsertion complications.

    PubMed

    Paulson, Pamela R; Miller, Kellee M

    2008-01-01

    Peripherally inserted central catheters (PICCs) continue to be necessary in neonatal care. They benefit many premature infants and those needing long-term intravenous access. An experienced inserter, early recognition of PICC candidates, early PICC placement, knowledge of anatomy, and correct choice of vein all increase placement success. As with any invasive procedure, there are risks. These include pain, difficulty advancing the catheter, damage to vessels, catheter malposition, and bleeding. Utilizing assessment skills, following the product manufacturer's instructions, and carefully placing the catheter should minimize most of these risks. Additional risks include postinsertion complications such as occlusions, thrombosis, catheter failure, infection, and catheter malposition. Proper nursing care--which includes controlling infection, properly securing the catheter, and changing the dressing as needed--is key to preventing complications and maintaining the PICC until treatment has been completed.

  9. Ocular inserts — Advancement in therapy of eye diseases

    PubMed Central

    Kumari, Anita; Sharma, Pramod K.; Garg, Vipin K.; Garg, Garima

    2010-01-01

    The ocular insert represents a significant advancement in the therapy of eye disease. Ocular inserts are defined as sterile, thin, multilayered, drug-impregnated, solid or semisolid consistency devices placed into the cul-de-sac or conjuctival sac, whose size and shape are especially designed for ophthalmic application. They are composed of a polymeric support that may or may not contain a drug. The drug can later be incorporated as dispersion or a solution in the polymeric support. They offer several advantages as increased ocular residence and sustained release of medication into the eye. The insert includes a body portion sized to position within a lachrymal canaliculus of the eyelid. The inserts are classified according to their solubility as insoluble, soluble, or bioerodible inserts. The release of drug from the insert depends upon the diffusion, osmosis, and bioerosion of the drug, and this article is an attempt to present a brief about this newer drug delivery system. PMID:22247860

  10. Core Vessel Insert Handling Robot for the Spallation Neutron Source

    SciTech Connect

    Graves, Van B; Dayton, Michael J

    2011-01-01

    The Spallation Neutron Source provides the world's most intense pulsed neutron beams for scientific research and industrial development. Its eighteen neutron beam lines will eventually support up to twenty-four simultaneous experiments. Each beam line consists of various optical components which guide the neutrons to a particular instrument. The optical components nearest the neutron moderators are the core vessel inserts. Located approximately 9 m below the high bay floor, these inserts are bolted to the core vessel chamber and are part of the vacuum boundary. They are in a highly radioactive environment and must periodically be replaced. During initial SNS construction, four of the beam lines received Core Vessel Insert plugs rather than functional inserts. Remote replacement of the first Core Vessel Insert plug was recently completed using several pieces of custom-designed tooling, including a highly complicated Core Vessel Insert Robot. The design of this tool are discussed.

  11. Comparison of Postoperative Drain Insertion versus No Drain Insertion in Thyroidectomies

    PubMed Central

    Al-Habsi, Asma S.; Al-Sulaimani, Al-Anood K.; Taqi, Kadhim M.; Al-Qadhi, Hani A.

    2016-01-01

    Objectives A thyroidectomy is a frequently performed surgical procedure which can result in life-threatening complications. The insertion of a drain after a thyroidectomy has been suggested to prevent such complications. This study aimed to evaluate the use of surgical drains following thyroidectomies in relation to postoperative complications and mass sizes. Methods This retrospective case-control study included all thyroidectomies conducted at the Sultan Qaboos University Hospital, Muscat, Oman, from January 2011 to December 2013. Length of hospital stay, readmission, postoperative complications and mass size were evaluated. Results During the study period, 250 surgeries were carried out on 241 patients. The majority of patients were female (87.2%). Drains were inserted postoperatively after 202 surgeries (80.8%) compared to 48 surgeries (19.2%) without drains. A total of 32 surgeries (12.8%) were conducted on patients with thyroid masses <1 cm, 138 (55.2%) on those with masses between 1–4 cm and 80 (32.0%) on those with masses >4 cm. The association between drain use and mass size was not significant (P = 0.439). Although postoperative complications were more prevalent in patients with drains, the relationship between these factors was not significant (P >0.050). Length of hospital stay was significantly longer among patients with postoperative drains (P <0.010). Conclusion The routine insertion of drains after thyroid surgeries was found to result in longer hospital stays and did not reduce rates of post-thyroidectomy complications. Thyroid mass size should not be used as an indicator for the insertion of a drain after thyroidectomy. PMID:28003893

  12. Planar slim-edge pixel sensors for the ATLAS upgrades

    NASA Astrophysics Data System (ADS)

    Altenheiner, S.; Goessling, C.; Jentzsch, J.; Klingenberg, R.; Lapsien, T.; Muenstermann, D.; Rummler, A.; Troska, G.; Wittig, T.

    2012-02-01

    The ATLAS detector at CERN is a general-purpose experiment at the Large Hadron Collider (LHC). The ATLAS Pixel Detector is the innermost tracking detector of ATLAS and requires a sufficient level of hermeticity to achieve superb track reconstruction performance. The current planar n-type pixel sensors feature a pixel matrix of n+-implantations which is (on the opposite p-side) surrounded by so-called guard rings to reduce the high voltage stepwise towards the cutting edge and an additional safety margin. Because of the inactive region around the active area, the sensor modules have been shingled on top of each other's edge which limits the thermal performance and adds complexity in the present detector. The first upgrade phase of the ATLAS pixel detector will consist of the insertable b-layer (IBL), an additional b-layer which will be inserted into the present detector in 2013. Several changes in the sensor design with respect to the existing detector had to be applied to comply with the IBL's specifications and are described in detail. A key issue for the ATLAS upgrades is a flat arrangement of the sensors. To maintain the required level of hermeticity in the detector, the inactive sensor edges have to be reduced to minimize the dead space between the adjacent detector modules. Unirradiated and irradiated sensors with the IBL design have been operated in test beams to study the efficiency performance in the sensor edge region and it was found that the inactive edge width could be reduced from 1100 μm to less than 250 μm.

  13. Large insert environmental genomic library production.

    PubMed

    Taupp, Marcus; Lee, Sangwon; Hawley, Alyse; Yang, Jinshu; Hallam, Steven J

    2009-09-23

    The vast majority of microbes in nature currently remain inaccessible to traditional cultivation methods. Over the past decade, culture-independent environmental genomic (i.e. metagenomic) approaches have emerged, enabling researchers to bridge this cultivation gap by capturing the genetic content of indigenous microbial communities directly from the environment. To this end, genomic DNA libraries are constructed using standard albeit artful laboratory cloning techniques. Here we describe the construction of a large insert environmental genomic fosmid library with DNA derived from the vertical depth continuum of a seasonally hypoxic fjord. This protocol is directly linked to a series of connected protocols including coastal marine water sampling [1], large volume filtration of microbial biomass [2] and a DNA extraction and purification protocol [3]. At the outset, high quality genomic DNA is end-repaired with the creation of 5 -phosphorylated blunt ends. End-repaired DNA is subjected to pulsed-field gel electrophoresis (PFGE) for size selection and gel extraction is performed to recover DNA fragments between 30 and 60 thousand base pairs (Kb) in length. Size selected DNA is purified away from the PFGE gel matrix and ligated to the phosphatase-treated blunt-end fosmid CopyControl vector pCC1 (EPICENTRE http://www.epibio.com/item.asp?ID=385). Linear concatemers of pCC1 and insert DNA are subsequently headfull packaged into phage particles by lambda terminase, with subsequent infection of phage-resistant E. coli cells. Successfully transduced clones are recovered on LB agar plates under antibiotic selection and archived in 384-well plate format using an automated colony picking robot (Qpix2, GENETIX). The current protocol draws from various sources including the CopyControl Fosmid Library Production Kit from EPICENTRE and the published works of multiple research groups [4-7]. Each step is presented with best practice in mind. Whenever possible we highlight subtleties

  14. Technical Note: Computer-Manufactured Inserts for Prosthetic Sockets

    PubMed Central

    Sanders, Joan E.; McLean, Jake B.; Cagle, John C.; Gardner, David W.; Allyn, Katheryn J.

    2016-01-01

    The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant’s test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11 mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03 mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. PMID:27212209

  15. Development of collimator insert for linac based stereotactic irradiation.

    PubMed

    Singh, I R; Brindha, S; Ravindran, B P; John, S; Rajshekhar, V; Rangad, F V; Roul, R K

    1999-10-01

    The aim of this study is to develop collimator inserts of various sizes which are either not commercially available or are expensive to import. The dosimetry parameters such as tissue maximum ratio (TMR), off-axis ratio (OAR) and output factor of the developed collimator insert are compared with that of the commercial collimator insert (Radionics). In order to check the suitability of the collimator insert developed locally for clinical use and to standardize the method of development, a collimator insert of 15 mm identical to the one supplied by Radionics is developed with low-melting alloy (Cerrobend). Moreover for the clinical use of the developed collimator insert, certain acceptance tests are performed which include a collimator concentricity test, beam size check and radiation leakage test. The dose verification is carried out with a thermoluminescent dosimeter (7LiF rods) and an FBX chemical dosimeter in a human-head-shaped Perspex phantom filled with water. The variation between the calculated and measured dose is found to be within +2.4% for 7LiF rods and -2.0% for the FBX chemical dosimeter thus ensuring the suitability of the developed collimator insert for clinical use. This has encouraged us to standardize the method adapted to develop the collimator insert and to develop collimator inserts of different field sizes.

  16. Threaded insert for compact cryogenic-capable pressure vessels

    DOEpatents

    Espinosa-Loza, Francisco; Ross, Timothy O.; Switzer, Vernon A.; Aceves, Salvador M.; Killingsworth, Nicholas J.; Ledesma-Orozco, Elias

    2015-06-16

    An insert for a cryogenic capable pressure vessel for storage of hydrogen or other cryogenic gases at high pressure. The insert provides the interface between a tank and internal and external components of the tank system. The insert can be used with tanks with any or all combinations of cryogenic, high pressure, and highly diffusive fluids. The insert can be threaded into the neck of a tank with an inner liner. The threads withstand the majority of the stress when the fluid inside the tank that is under pressure.

  17. The carpal insertions of the transverse carpal ligament.

    PubMed

    Manley, Mollie; Boardman, Matthew; Goitz, Robert J

    2013-04-01

    To quantitatively define the anatomic insertions of the transverse carpal ligament (TCL) to the carpals. We dissected 5 fresh-frozen cadaver limbs, isolating the TCL. The ligament insertion sites into bone were clearly marked and photographed. We then used computer software to measure the area of insertion into the individual carpals. The TCL had consistent insertion sites into the scaphoid, trapezium, pisiform, and hamate. The average insertion of the TCL on the scaphoid was 6 × 6 mm (proximal to distal × radial to ulnar maximum distance), trapezium 13 × 6 mm, pisiform 9 × 6 mm, and hamate 11 × 5 mm. The area of ligament insertion on the scaphoid was 29 mm(2), trapezium was 42 mm(2), pisiform was 38 mm(2), and hamate was 40 mm(2). The perimeter of the ligament insertion on the scaphoid was 21 mm, trapezium was 28 mm, pisiform was 25 mm, and hamate was 29 mm. The TCL has a broad but definable footprint on the trapezium and scaphoid on the radial side and the hamate and the pisiform on the ulnar side of the carpal tunnel. The distal carpal insertion sites are longer and oblong, whereas the proximal insertion sites are more circular. Precise knowledge of TCL attachment sites may allow the surgeon greater confidence and safety during procedures that involve its release, such as carpal tunnel release, trapeziectomy, hook of hamate excision, or Guyon canal release. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  18. Effect of vibration frequency on biopsy needle insertion force.

    PubMed

    Tan, Lei; Qin, Xuemei; Zhang, Qinhe; Zhang, Hongcai; Dong, Hongjian; Guo, Tuodang; Liu, Guowei

    2017-05-01

    Needle insertion is critical in many clinical medicine procedures, such as biopsy, brachytherapy, and injection therapy. A platform with two degrees of freedom was set up to study the effect of vibration frequency on needle insertion force. The gel phantom deformation at the needle cutting edge and the Voigt model are utilized to develop a dynamic model to explain the relationship between the insertion force and needle-tip velocity. The accuracy of this model was verified by performing needle insertions into phantom gel. The effect of vibration on insertion force can be explained as the vibration increasing the needle-tip velocity and subsequently increasing the insertion force. In a series of needle insertion experiments with different vibration frequencies, the peak forces were selected for comparison to explore the effect of vibration frequency on needle insertion force. The experimental results indicate that the insertion force at 500Hz increases up to 17.9% compared with the force at 50Hz. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Insertion kinetics of small nucleotides through single walled carbon nanotube.

    PubMed

    Clavier, A; Kraszewski, S; Ramseyer, C; Picaud, F

    2013-03-10

    We report molecular dynamic simulations showing that a DNA molecule constituted by five unique bases can be spontaneously inserted into single walled carbon nanotube (SWCNT) in normal conditions (P, T and water environment) depending on the tube radius value. The van der Waals and electrostatic interactions play a central role for the rapid insertion process. Our study shows also that the Guanine molecule inserts the fastest compared to thymine, adenine and cytosine bases, respectively. The differences of insertion time could be exploited for applications concerning for example DNA sequencing. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. [Insertion of biliary endoprosthesis as ambulatory procedure].

    PubMed

    Güitrón, A; Adalid, R; Barinagarrementería, R; Gutiérrez-Bermúdez, J A

    2001-01-01

    Because of possible complications, it has been common practice to admit to the hospital most if not all patients undergoing therapeutic ERCP. Therefore, little descriptive data exist on the safety of out-patient therapeutic ERCP for endobiliary stent placement. To assure quality patient care and patient safety, we reviewed our experience with out-patient therapeutic ERCP for palliation of benign and malignant common bile duct obstruction by means of endobiliary stent insertion. PATIENTS-METHODS AND RESULTS: A retrospective review of all therapeutic ERCPs for palliation of benign and malignant common bile duct obstruction with endobiliary stents was performed from January 1, 1998, through December 31, 1999. One hundred forty therapeutic ERCPs were performed to place an endobiliary stent for benign and malignant common bile duct obstruction. Seventy-two procedures were performed on out-patients, sixty-eight on in-patients. There was no significant difference between out-patient and in-patient groups with regard to age, gender, need for endoscopic sphincterotomy, and complication rate. In patients had one procedure-related complication; out patients had four. There was no procedure-related mortality in either group. Therapeutic ERCP for palliation of benign and malignant common bile duct obstruction with endobiliary stents can be safely and successfully performed on an out-patient basis for selected patients. This should result in substantial cost savings.

  1. Biosynthesis and Insertion of the Molybdenum Cofactor.

    PubMed

    Magalon, Axel; Mendel, Ralf R

    2015-01-01

    The transition element molybdenum (Mo) is of primordial importance for biological systems, because it is required by enzymes catalyzing key reactions in the global carbon, sulfur, and nitrogen metabolism. To gain biological activity, Mo has to be complexed by a special cofactor. With the exception of bacterial nitrogenase, all Mo-dependent enzymes contain a unique pyranopterin-based cofactor coordinating a Mo atom at their catalytic site. Various types of reactions are catalyzed by Mo-enzymes in prokaryotes including oxygen atom transfer, sulfur or proton transfer, hydroxylation, or even nonredox reactions. Mo-enzymes are widespread in prokaryotes and many of them were likely present in the Last Universal Common Ancestor. To date, more than 50--mostly bacterial--Mo-enzymes are described in nature. In a few eubacteria and in many archaea, Mo is replaced by tungsten bound to the same unique pyranopterin. How Mo-cofactor is synthesized in bacteria is reviewed as well as the way until its insertion into apo-Mo-enzymes.

  2. Insertional Polymorphisms of Endogenous Feline Leukemia Viruses

    PubMed Central

    Roca, Alfred L.; Nash, William G.; Menninger, Joan C.; Murphy, William J.; O'Brien, Stephen J.

    2005-01-01

    The number, chromosomal distribution, and insertional polymorphisms of endogenous feline leukemia viruses (enFeLVs) were determined in four domestic cats (Burmese, Egyptian Mau, Persian, and nonbreed) using fluorescent in situ hybridization and radiation hybrid mapping. Twenty-nine distinct enFeLV loci were detected across 12 of the 18 autosomes. Each cat carried enFeLV at only 9 to 16 of the loci, and many loci were heterozygous for presence of the provirus. Thus, an average of 19 autosomal copies of enFeLV were present per cat diploid genome. Only five of the autosomal enFeLV sites were present in all four cats, and at only one autosomal locus, B4q15, was enFeLV present in both homologues of all four cats. A single enFeLV occurred in the X chromosome of the Burmese cat, while three to five enFeLV proviruses occurred in each Y chromosome. The X chromosome and nine autosomal enFeLV loci were telomeric, suggesting that ectopic recombination between nonhomologous subtelomeres may contribute to enFeLV distribution. Since endogenous FeLVs may affect the infectiousness or pathogenicity of exogenous FeLVs, genomic variation in enFeLVs represents a candidate for genetic influences on FeLV leukemogenesis in cats. PMID:15767400

  3. Insertion devices for DORIS III (invited)

    NASA Astrophysics Data System (ADS)

    Pflüger, J.

    1992-01-01

    Recently, a major reconstruction of the electron storage ring DORIS II, the DORIS III project, has been completed [W. Brefeld, H. Nesemann, and J. Rossbach, Proceedings of the European Particle Accelerator Conference, Rome (World Scientific, Singapore, 1988), p. 2389]. Figure 1 shows an overview of the new ring. Originally DORIS II had a twofold symmetry. In part C each of the two dipole magnets adjacing to the 65-m-long straight section was replaced by three corresponding weaker ones. In this way a total of seven straight sections for insertion devices are provided. Six of them are 4-m long and the one in the center is only 2.7-m long. After extensive discussions with the user groups involved, four x-ray wigglers, one asymmetric hybrid structure, one x-ray undulator, and one XUV multiple undulator of the revolver type have been proposed for six of the sections [J. Pflüger and P. Gurtler, Nucl. Instrum. Methods A 287, 628 (1990)]. One section is presently still free. All devices are either in construction or have already been completed and installed. In this contribution the mechanical and magnetic design of these devices will be described. Results of magnetic measurements of those devices which are already completed will be given in more detail.

  4. Phoenix Conductivity Probe Inserted into Martian Soil

    NASA Technical Reports Server (NTRS)

    2008-01-01

    NASA's Phoenix Mars Lander inserted the four needles of its thermal and conductivity probe into Martian soil during the 98th Martian day, or sol, of the mission and left it in place until Sol 99 (Sept. 4, 2008).

    The Robotic Arm Camera on Phoenix took this image on the morning of Sol 99 while the probe's needles were in the ground. The science team informally named this soil target 'Gandalf.'

    The thermal and conductivity probe measures how fast heat and electricity move from one needle to an adjacent one through the soil or air between the needles. Conductivity readings can be indicators about water vapor, water ice and liquid water.

    The probe is part of Phoenix's Microscopy, Electrochemistry and Conductivity suite of instruments.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  5. Replicative resolution of integron cassette insertion

    PubMed Central

    Loot, Céline; Ducos-Galand, Magaly; Escudero, José Antonio; Bouvier, Marie; Mazel, Didier

    2012-01-01

    Site-specific recombination catalyzed by tyrosine recombinases follows a common pathway consisting of two consecutive strand exchanges. The first strand exchange generates a Holliday junction (HJ), which is resolved by a second strand exchange. In integrons, attC sites recombine as folded single-stranded substrates. Only one of the two attC site strands, the bottom one, is efficiently bound and cleaved by the integrase during the insertion of gene cassettes at the double-stranded attI site. Due to the asymmetry of this complex, a second strand exchange on the attC bottom strand (bs) would form linearized abortive recombination products. We had proposed that HJ resolution would rely on an uncharacterized mechanism, probably replication. Using an attC site carried on a plasmid with each strand specifically tagged, we followed the destiny of each strand after recombination. We demonstrated that only one strand, the one carrying the attC bs, is exchanged. Furthermore, we show that the recombination products contain the attC site bs and its entire de novo synthesized complementary strand. Therefore, we demonstrate the replicative resolution of single-strand recombination in integrons and rule out the involvement of a second strand exchange of any kind in the attC × attI reaction. PMID:22740653

  6. ACE insert/delete polymorphism and atherosclerosis.

    PubMed

    Scheer, W Douglas; Boudreau, Donald A; Hixson, James E; McGill, Henry C; Newman, William P; Tracy, Richard E; Zieske, Arthur W; Strong, Jack P

    2005-02-01

    We report on the results of a large autopsy study focusing upon the hypothesis that deletion of the Alu insert in the angiotensin converting enzyme (ACE) gene is associated with: (a) greater prevalence or extent of atherosclerosis in the aorta and coronary arteries; and (b) microscopic qualities of established atherosclerotic plaques in the coronary arteries. This study was conducted in young US black (n=290) and white (n=379) males using available materials and data from the Pathobiological Determinants of Atherosclerosis in Youth (PDAY) study, a multi-center cooperative autopsy study organized in 1985 to explore the relationships of known cardiovascular risk factors to atherosclerosis in victims of accidents, homicides, or suicides in the age range of 15-34 years. The results provide strong evidence that ACE genotype may not be a predictor of either the prevalence or the extent of the lesions of atherosclerosis in the right coronary artery or the aorta of young adults, an observation that confirms previous studies that estimated the prevalence and extent of atherosclerosis using coronary angiography. In addition, the results suggest that ACE genotype does not contribute to the formation of atherosclerotic lesions that have the characteristics of vulnerable plaques in the left anterior descending coronary artery of young adults.

  7. Antibody binding loop insertions as diversity elements

    PubMed Central

    Kiss, Csaba; Fisher, Hugh; Pesavento, Emanuele; Dai, Minghua; Valero, Rosa; Ovecka, Milan; Nolan, Rhiannon; Phipps, M. Lisa; Velappan, Nileena; Chasteen, Leslie; Martinez, Jennifer S.; Waldo, Geoffrey S.; Pavlik, Peter; Bradbury, Andrew R.M.

    2006-01-01

    In the use of non-antibody proteins as affinity reagents, diversity has generally been derived from oligonucleotide-encoded random amino acids. Although specific binders of high-affinity have been selected from such libraries, random oligonucleotides often encode stop codons and amino acid combinations that affect protein folding. Recently it has been shown that specific antibody binding loops grafted into heterologous proteins can confer the specific antibody binding activity to the created chimeric protein. In this paper, we examine the use of such antibody binding loops as diversity elements. We first show that we are able to graft a lysozyme-binding antibody loop into green fluorescent protein (GFP), creating a fluorescent protein with lysozyme-binding activity. Subsequently we have developed a PCR method to harvest random binding loops from antibodies and insert them at predefined sites in any protein, using GFP as an example. The majority of such GFP chimeras remain fluorescent, indicating that binding loops do not disrupt folding. This method can be adapted to the creation of other nucleic acid libraries where diversity is flanked by regions of relative sequence conservation, and its availability sets the stage for the use of antibody loop libraries as diversity elements for selection experiments. PMID:17023486

  8. IYA2009 newspaper insert in your community

    NASA Astrophysics Data System (ADS)

    Harvey, J.

    2008-06-01

    The Gemini PIO (Public Information Officer) offers suggestions on how to approach your local newspaper about a newspaper insert for your community being published during IYA2009. Local government support, articles by astronomers, advertisers, and appointing someone within your organisation to manage the content will be discussed. We will explain the timeline required, the number of personnel hours required, developmental stages and income a local newspaper would have to generate to produce a quality, table-top supplement. In 2003, over 30,000 copies of Stars over Mauna Kea, a special supplement in tabloid format were produced and distributed in the local newspapers in Hilo, Hawaii. The publication, 48 pages in total, featured profiles of the observatories on Mauna Kea, stories about the geology and legends of Mauna Kea, and historical information about the evolution of astronomy in Hawaii. In additionthe publication included a series of essays titled In their own words. These articles were written by key members of the astronomy community. Sixty thousand copies of Stars over Mauna Kea II were printed as a follow-up to the first edition in 2005. This second edition included an article on the `Imiloa Astronomy Education Center, explanations about the types of telescopes on Mauna Kea and columns written by scientists about the fascinating and significant discoveries made on Hawaii. Personal stories about careers in astronomy were also highlighted. In Chile, a similar eight-page supplement, featuring Gemini, CTIO and SOAR telescopes, was published in 2005 and 5000 copies were distributed throughout the country.

  9. Phoenix Conductivity Probe Inserted into Martian Soil

    NASA Technical Reports Server (NTRS)

    2008-01-01

    NASA's Phoenix Mars Lander inserted the four needles of its thermal and conductivity probe into Martian soil during the 98th Martian day, or sol, of the mission and left it in place until Sol 99 (Sept. 4, 2008).

    The Robotic Arm Camera on Phoenix took this image on the morning of Sol 99 while the probe's needles were in the ground. The science team informally named this soil target 'Gandalf.'

    The thermal and conductivity probe measures how fast heat and electricity move from one needle to an adjacent one through the soil or air between the needles. Conductivity readings can be indicators about water vapor, water ice and liquid water.

    The probe is part of Phoenix's Microscopy, Electrochemistry and Conductivity suite of instruments.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  10. In vivo evaluation of needle force and friction stress during insertion at varying insertion speed into the brain.

    PubMed

    Casanova, Fernando; Carney, Paul R; Sarntinoranont, Malisa

    2014-11-30

    Convection enhanced delivery (CED) infuses drugs directly into brain tissue. Needle insertion is required and results in tissue damage which can promote flowback along the needle track and improper targeting. The goal of this study was to evaluate friction stress (calculated from needle insertion force) as a measure of tissue contact and damage during needle insertion for varying insertion speeds. Forces and surface dimpling during needle insertion were measured in rat brain in vivo. Needle retraction forces were used to calculate friction stresses. These measures were compared to track damage from a previous study. Differences between brain tissues and soft hydrogels were evaluated for varying insertion speeds: 0.2, 2, and 10mm/s. In brain tissue, average insertion force and surface dimpling increased with increasing insertion speed. Average friction stress along the needle-tissue interface decreased with insertion speed (from 0.58 ± 0.27 to 0.16 ± 0.08 kPa). Friction stress varied between brain regions: cortex (0.227 ± 0.27 kPa), external capsule (0.222 ± 0.19 kPa), and CPu (0.383 ± 0.30 kPa). Hydrogels exhibited opposite trends for dimpling and friction stress with insertion speed. Previously, increasing needle damage with insertion speed has been measured with histological methods. Friction stress appears to decrease with increasing tissue damage and decreasing tissue contact, providing the potential for in vivo and real time evaluation along the needle track. Force derived friction stress decreased with increasing insertion speed and was smaller within white matter regions. Hydrogels exhibited opposite trends to brain tissue. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Roles of carboxyl groups in the transmembrane insertion of peptides

    PubMed Central

    Barrera, Francisco N.; Weerakkody, Dhammika; Anderson, Michael; Andreev, Oleg A.; Reshetnyak, Yana K.; Engelman, Donald M.

    2011-01-01

    We have used the pHLIP® peptide to study the roles of carboxyl groups in transmembrane peptide insertion. The pH (low) insertion peptide (pHLIP) binds to the surface of a lipid bilayer as a disordered peptide at neutral pH, and when the pH is lowered it inserts across the membrane to form a transmembrane helix. Peptide insertion is reversed when the pH is raised above the characteristic pKa (6.0). A key event facilitating the membrane insertion is the protonation of aspartic (Asp) and/or glutamic (Glu) acid residues, since at neutral pH their negatively charged side chains hinder membrane insertion. In order to gain mechanistic understanding, we studied the membrane insertion and exit of a series of pHLIP variants where the four Asp residues were sequentially mutated to nonacidic residues, including histidine (His). Our results show that the presence of His residues does not prevent the pH-dependent peptide membrane insertion at ~pH 4 driven by the protonation of carboxyl groups at the inserting end of the peptide. A further pH drop leads to the protonation of His residues in the TM part of peptide, which induces peptide exit from the bilayer. We also find that the number of ionizable residues that undergo a change in protonation during membrane insertion correlates with the pH-dependent insertion into and exit from the lipid bilayer, and that cooperativity increases with their number. We expect that our understanding will be used to improve the targeting of acidic diseased tissue by pHLIP peptides. PMID:21888917

  12. Cruciate retaining and cruciate substituting ultra-congruent insert

    PubMed Central

    Deledda, Davide; Rosso, Federica; Ratto, Nicola; Bruzzone, Matteo; Bonasia, Davide Edoardo; Rossi, Roberto

    2016-01-01

    The posterior cruciate ligament (PCL) conservation and the polyethylene insert constraint in total knee arthroplasty (TKA) are still debated. The PCL is one of the primary stabilizers of the joint, but cruciate retaining (CR) implants have the disadvantage of a difficult balancing of the PCL. Postero-stabilized (PS) implants were introduced to reduce this problem. However, also the PS implants have some disadvantages, due to the cam-mechanism, such as high risk of cam-mechanism polyethylene wear. To minimize the polyethylene wear of the cam-mechanism and the bone sacrifice due to the intercondylar box, different types of inserts were developed, trying to increase the implant conformity and to reduce stresses on the bone-implant interface. In this scenario ultra-congruent (UC) inserts were developed. Those inserts are characterized by a high anterior wall and a deep-dished plate. This conformation should guarantee a good stability without the posterior cam. Few studies on both kinematic and clinical outcomes of UC inserts are available. Clinical and radiological outcomes, as well as kinematic data are similar between UC mobile bearing (MB) and standard PS MB inserts at short to mid-term follow-up. In this manuscript biomechanics and clinical outcomes of UC inserts will be described, and they will be compared to standard PS or CR inserts. PMID:26855938

  13. Rhinosinusitis; A Potential Hazard of Nasogastric Tube Insertion

    PubMed Central

    Adeyemo, Adebolajo A.; Fasunla, Ayotunde J.; Adeosun, Aderemi A.; Abdullahi, Hamisu

    2007-01-01

    The nasogastric tube has been used frequently for enteral feeding and as an intranasal oxygen catheter. This practice is however associated with complications. We present a case of rhinosinusitis and sepsis in a diabetic patient following the insertion of a nasogastric tube. Physicians should be aware of sinusitis as a possible cause of sepsis in patients with nasogastric tube insertion. PMID:25161433

  14. Astronaut John Glenn practices insertion into Mercury spacecraft

    NASA Technical Reports Server (NTRS)

    1962-01-01

    Astronaut John H. Glenn Jr., pilot of the Mercury-Atlas 6 mission, practices insertion into the Mercury 'Friendship 7' spacecraft during MA-6 preflight training activity at Cape Canveral, Florida. He is wearing the full pressure suit and helmet (00993); Glenn practices insertion into Mercury capsule with help of a McDonnell Aircraft Corporation technician (00994).

  15. Load beam unit replaceable inserts for dry coal extrusion pumps

    DOEpatents

    Saunders, Timothy; Brady, John D.

    2012-11-13

    A track assembly for a particulate material extrusion pump according to an exemplary aspect of the present disclosure includes a link assembly with a roller bearing. An insert mounted to a load beam located such that the roller bearing contacts the insert.

  16. Combined plasma and thermal hollow cathode insert model

    NASA Technical Reports Server (NTRS)

    Katz, Ira; Polk, James E.; Mikellides, Ionnis G.; Goebel, Dan m.; Hornbeck, Sarah E.

    2005-01-01

    In this paper, we present the first results from a Hollow Cathode Thermal (HCThermal) model that uses the spatially distributed plasma fluxes calculated by the InsertRegion of an Orificed Cathode (IROrCa2D) code as the heat source to predict the hollow cathode and insert temperatures.

  17. A Microscopic View of Phospholipid Insertion into Biological Membranes

    PubMed Central

    Vermaas, Josh V.; Tajkhorshid, Emad

    2014-01-01

    Understanding the process of membrane insertion is an essential step in developing a detailed mechanism, e.g., for peripheral membrane protein association and membrane fusion. The Highly Mobile Membrane Mimetic (HMMM) has been used to accelerate the membrane association and binding of peripheral membrane proteins in simulations by increasing the lateral diffusion of phospholipid headgroups while retaining an atomistic description of the interface. Through a comparative study, we assess the difference in insertion rate of a free phospholipid into an HMMM as well as into a conventional phospholipid bilayer, and develop a detailed mechanistic model of free phospholipid insertion into biological membranes. The mechanistic insertion model shows that successful, irreversible association of the free phospholipid to the membrane interface, which results in its insertion, is the rate limiting step. Association is followed by independent, sequential insertion of the acyl tails of the free phospholipid into the membrane, with splayed acyl tail intermediates. Use of the HMMM is found to replicate the same intermediate insertion states as in the full phospholipid bilayer, however it accelerates overall insertion by approximately a factor of three, with the probability of successful association of phospholipid to the membrane being significantly enhanced. PMID:24313792

  18. Orbit Insertion by Mars Reconnaissance Orbiter (Artist's Concept)

    NASA Technical Reports Server (NTRS)

    2005-01-01

    This is an artist's concept of NASA's Mars Reconnaissance Orbiter during the critical process of Mars orbit insertion. In order to be captured into orbit around Mars, the spacecraft must conduct a 25-minute rocket burn when it is just shy of reaching the planet. As pictured, it will pass under the red planet's southern hemisphere as it begins the insertion burn.

  19. Tube thoracostomy: Increased angle of insertion is associated with complications.

    PubMed

    Hernandez, Matthew C; Laan, Danuel V; Zimmerman, Stacey L; Naik, Nimesh D; Schiller, Henry J; Aho, Johnathon M

    2016-08-01

    Tube thoracostomy (TT), considered a routine procedure, has significant complications. Current recommendations for placement rely on surface anatomy. There is no information to guide operators regarding angle of insertion relative to chest wall. We aim to determine if angle of insertion is associated with complications of TT. We performed a retrospective review of adult trauma patients who necessitated TT at a Level I trauma center over a 2-year period (January 2012 to December 2013). Tube thoracostomies performed intraoperatively or using radiological guidance were excluded. Thoracic anteroposterior or posteroanterior radiographs were reviewed to determine the angle of insertion of TT relative to the thoracic wall. A previously validated classification method was used to categorize complications. Descriptive and univariate statistics were used to compare angle of insertion and complicated versus uncomplicated TT. Review identified 154 patients who underwent a total of 246 TT placed for emergent trauma. All patients had a postprocedural chest x-ray. We identified 90 complications (37%) over the study period. One hundred forty-four of the TTs reviewed had an angle of insertion less than 45 degrees of which there were 27 complications (19%). One hundred two of the TTs had an angle greater than 45 degrees and 63 complications (62%); p < 0.0001. Tube thoracostomy insertion is inherently dangerous. Placement of TT using a higher angle of insertion greater than 45 degrees is associated with increased complications. Further prospective studies quantifying TT angle of insertion on outcomes are needed. Therapeutic study, level IV.

  20. [Umbilical and peripherally inserted venous central catheterization of the newborn].

    PubMed

    Bouissou, A; Rakza, T; Storme, L; Lafarghe, A; Fily, A; Diependaele, J-F; Dalmas, S

    2008-09-01

    Umbilical venous and peripherally inserted venous central catheters are widely used to perfuse low-weight preterm and term newborns in intensive care units. This catheter must be inserted carefully and monitored rigorously to prevent complications. This paper develops today's knowledge on the use and complications in the newborn population.

  1. Gastrostomy tube insertion in children: the Edmonton experience.

    PubMed

    Ackroyd, Ryan; Saincher, Meghana; Cheng, Simon; El-Matary, Wael

    2011-05-01

    Although gastrostomy tube insertion - whether endoscopic or open - is generally safe, procedure-related complications have been reported. To compare gastrostomy tube insertion-related complications between percutaneous endoscopic gastrostomy and open gastrostomy at a single pediatric centre. The charts of children (younger than 17 years of age at the time of tube insertion) who underwent endoscopic or open gastrostomy tube insertion from January 2005 to December 2007 at the Stollery Children's Hospital (Edmonton, Alberta) were examined. A total of 298 children underwent gastrostomy tube insertion over a period of three years. After excluding patients with incomplete charts, 160 children (91 boys, mean [± SD] age 3.18 ± 4.73 years) were included. Eighty-five children (mean age 4.50 ± 5.40 years) had their gastrostomy tube inserted endoscopically, while the remaining 75 (mean age 1.68 ± 3.27 years; P<0.001) underwent an open procedure. The overall rate of major complications was 10.2% for the endoscopic technique and 8.6% for the open technique (P=0.1). Major infections were higher in the endoscopic technique group, while persistent gastrocutaneous fistulas after tube removal were more common in the open technique group. Although the rate of major complications was similar between the endoscopic and open tube insertion groups, major infections were more common among children who underwent endoscopic gastrostomy. The decision for gastrostomy tube insertion was primarily based on clinical background.

  2. Piezo-Driven Vibrating Insertion Device for Microelectrode Array

    NASA Astrophysics Data System (ADS)

    Noda, Takahiro; Kanzaki, Ryohei; Takahashi, Hirokazu

    Microelectrode arrays are commonly used to measure neural activities in the brain, and arrays with some 100 electrodes are commercially available to date. However, insertion of a dense grid array deforms the brain, resulting in deterioration of the measurements. In order to overcome this problem, we propose a piezo-driven vibrating insertion device to reduce the insertion-induced deformation of the brain. We attempted under various conditions to insert the array into an agarose substrate, whose hardness was adjusted to that of the cerebral cortex of rats. Our experiments demonstrated that inverse-sawtooth vibration reduced the insertion-induced deformation of the substrate in proportion to the logarithm of an upstroke velocity when the velocity was higher than 10 mm/s, and vibrating insertion of the maximum velocity at 36.7 mm/s reduced the deformation by up to 40% as compared to insertion without vibration. In addition, we tested the vibrating insertion device in an electrophysiological experiment in the rat auditory cortex in vivo, and successfully measured tone-evoked neuronal activities.

  3. Combined plasma and thermal hollow cathode insert model

    NASA Technical Reports Server (NTRS)

    Katz, Ira; Polk, James E.; Mikellides, Ionnis G.; Goebel, Dan m.; Hornbeck, Sarah E.

    2005-01-01

    In this paper, we present the first results from a Hollow Cathode Thermal (HCThermal) model that uses the spatially distributed plasma fluxes calculated by the InsertRegion of an Orificed Cathode (IROrCa2D) code as the heat source to predict the hollow cathode and insert temperatures.

  4. Interface study of insertion layers in organic semiconductor devices

    NASA Astrophysics Data System (ADS)

    Ding, Huanjun; Irfan, "; So, Franky; Gao, Yongli

    2009-08-01

    Inserting an ultra-thin interlayer has been an important means in modifying the performance of organic semiconductor devices. Using photoemission and inverse photoemission spectroscopy (UPS, XPS and IPES), we have investigated the electronic structure of a number of insertion layers widely used in organic semiconductor devices. We found that inserting alkali metal compound thin layers such as LiF between the electron transport layer (ETL) and the cathode can induce energy level shift in the ETL that reduces the electron injection barrier. The reduction is attributed to the release of the alkali metal that n-doped the ETL, and as such it depends on the cathode material deposited on top of the insertion layer. For thin metal oxide insertion layers, such as MoO3, between the anode and the hole transport layer (HTL), reduction of the hole injection barrier is also observed. This reduction, however, is due to the large workfunction of the oxide that subsequently moves the highest occupied molecular orbital (HOMO) toward the anode Fermi level. Effects of other insertion layers, such as metal insertion layer in organic bistable device (OBD) and organic insertion layer in bipolar organic thin film transistors (OTFT) will also be discussed.

  5. Tuning the Insertion Properties of pHLIP

    PubMed Central

    Musial-Siwek, Monika; Karabadzhak, Alexander; Andreev, Oleg A.; Reshetnyak, Yana K.; Engelman, Donald M.

    2009-01-01

    The pH (low) insertion peptide (pHLIP) has exceptional characteristics: at neutral pH it is an unstructured monomer in solution or when bound to lipid bilayer surfaces, and it inserts across a lipid bilayer as a monomeric alpha-helix at acidic pH. The peptide targets acidic tissues in vivo, and may be useful in cancer biology for delivery of imaging or therapeutic molecules to acidic tumors. To find ways to vary its useful properties, we have designed and analyzed pHLIP sequence variants. We find that each of the Asp residues in the transmembrane segment is critical for solubility and pH-dependent membrane insertion of the peptide. Changing both of the Asp residues in the transmembrane segment to Glu, inserting an additional Asp into the transmembrane segment, or replacing either of the Asp residues with Ala leads to aggregation and/or loss of pH-dependent membrane insertion of the peptide. However, variants with either of the Asp residues changed to Glu remained soluble in an aqueous environment and inserted into the membrane at acidic pH with a higher pKapp of membrane insertion. Variation of the pH at which insertion occurs may broaden the potential uses of the pHLIP technology by allowing targeting of tissues with different acidity levels. PMID:19766589

  6. Z-2 Threaded Insert Design and Testing Abstract

    NASA Technical Reports Server (NTRS)

    Rhodes, RIchard; Graziosi, Dave; Jones, Bobby; Ferl, Jinny; Scarborough, Steve; Sweeney, Mitch

    2016-01-01

    The Z-2 Prototype Planetary Extravehicular Space Suit Assembly is a continuation of NASA's Z series of spacesuits. The Z-2 is another step in the NASA's technology development roadmap leading to human exploration of the Martian surface. To meet a more challenging set of requirements than previous suit systems standard design features, such as threaded inserts, have been re-analyzed and improved. NASA's Z-2 prototype space suit contains several components fabricated from an advanced hybrid composite laminate consisting of IM10 carbon fiber and fiber glass. One requirement NASA levied on the suit composites was the ability to have removable, replaceable helicoil inserts to which other suit components would be fastened. An approach utilizing bonded in inserts with helicoils inside of them was implemented. The design of the interface flanges of the composites allowed some of the inserts to be a "T" style insert that was installed through the entire thickness of the laminate. The flange portion of the insert provides a mechanical lock as a redundancy to the adhesive aiding in the pullout load that the insert can withstand. In some locations it was not possible to utilize at "T" style insert and a blind insert was used instead. These inserts rely completely on the bond strength of the adhesive to resist pullout. It was determined during the design of the suit that the inserts did not need to withstand loads induced from pressure cycling but instead tension induced from torqueing the screws to bolt on hardware which creates a much higher stress on them. Bolt tension is determined by dividing the torque on the screw by a k value multiplied by the thread diameter of the bolt. The k value is a factor that accounts for friction in the system. A common value used for k for a non-lubricated screw is 0.2. The k value can go down by as much as 0.1 if the screw is lubricated which means for the same torque, a much larger tension could be placed on the bolt and insert. This paper

  7. Intraaortic balloon pump insertion through the subclavian artery. Subclavian artery insertion of IABP.

    PubMed

    Marcu, Constantin B; Donohue, Thomas J; Ferneini, Antoine; Ghantous, Andre E

    2006-04-01

    The intraaortic balloon pump (IABP) is frequently used in the management of cardiac failure in the setting of myocardial infarction or as a bridge for coronary revascularisation surgery. The IABP is usually inserted through the femoral artery. Occasionally severe aorto-iliac occlusive disease prevents the retrograde passage of the balloon, in which case an anterograde route, usually through the ascending aorta is used. We describe four patients in whom an IABP was placed through the subclavian artery by the joint efforts of cardiologists and vascular surgeons.

  8. Measurement of Vein Diameter for Peripherally Inserted Central Catheter (PICC) Insertion: An Observational Study.

    PubMed

    Sharp, Rebecca; Cummings, Melita; Childs, Jessie; Fielder, Andrea; Mikocka-Walus, Antonina; Grech, Carol; Esterman, Adrian

    2015-01-01

    Choosing an appropriately sized vein reduces the risk of venous thromboembolism associated with peripherally inserted central catheters. This observational study described the diameters of the brachial, basilic, and cephalic veins and determined the effect of patient factors on vein size. Ultrasound was used to measure the veins of 176 participants. Vein diameter was similar in both arms regardless of hand dominance and side. Patient factors-including greater age, height, and weight, as well as male gender-were associated with increased vein diameter. The basilic vein tended to have the largest diameter statistically. However, this was the case in only 55% of patients.

  9. Detection for processing history of seam insertion and contrast enhancement

    NASA Astrophysics Data System (ADS)

    Li, Jianwei; Zhao, Yao; Ni, Rongrong

    2014-11-01

    With the development of manipulations techniques of digital images, digital image forensic technology is becoming more and more necessary. However, the determination of processing history of multi-operation is still a challenge problem. In this paper, we improve the traditional seam insertion algorithm, and propose corresponding detection method. Then an algorithm that focuses on detecting the processing history of seam insertion and contrast enhancement is proposed, which can be widely used in practical image forgery. Based on comprehensive analysis, we have discovered the inherent relationship between seam insertion and contrast enhancement. Different orders of processing make different impacts on images. By using the newly proposed algorithm, both contrast enhancement followed by seam insertion and seam insertion followed by contrast enhancement can be detected correctly. Plenty of experiments have been implemented to prove the accuracy.

  10. Gas turbine nozzle vane insert and methods of installation

    DOEpatents

    Miller, William John; Predmore, Daniel Ross; Placko, James Michael

    2002-01-01

    A pair of hollow elongated insert bodies are disposed in one or more of the nozzle vane cavities of a nozzle stage of a gas turbine. Each insert body has an outer wall portion with apertures for impingement-cooling of nozzle wall portions in registration with the outer wall portion. The insert bodies are installed into the cavity separately and spreaders flex the bodies toward and to engage standoffs against wall portions of the nozzle whereby the designed impingement gap between the outer wall portions of the insert bodies and the nozzle wall portions is achieved. The spreaders are secured to the inner wall portions of the insert bodies and the bodies are secured to one another and to the nozzle vane by welding or brazing.

  11. Smart structures for shock wave attenuation using ER inserts

    NASA Astrophysics Data System (ADS)

    Kim, Jaehwan; Kim, Jung-Yup; Choi, Seung-Bok; Kim, Kyung-Su

    2001-08-01

    This Paper demonstrates the possibility of shock wave attenuation propagating through a smart structure that incorporates ER insert. The wave transmission of ER inserted beam is theoretically derived using Mead & Markus model and the theoretical results are compared with the finite element analysis results. To experimentally verify the shock wave attenuation, ER insert in an aluminum plate is made and two piezoceramic disks are used as transmitter and receiver of the wave. The transmitter sends a sine pulse signal such that a component of shock wave travels through the plate structure and the receiver gets the transmitted wave signal. Wave propagation of the ER insert can be adjusted by changing the applied electric field on the ER insert. Details of the experiment are addressed and the possibility of shock wave attenuation is experimentally verified. This kind of smart structure can be used for warship and submarine hull structures to protect fragile and important equipment.

  12. Method for improving the durability of ion insertion materials

    DOEpatents

    Lee, Se-Hee; Tracy, C. Edwin; Cheong, Hyeonsik M.

    2002-01-01

    The invention provides a method of protecting an ion insertion material from the degradative effects of a liquid or gel-type electrolyte material by disposing a protective, solid ion conducting, electrically insulating, layer between the ion insertion layer and the liquid or gel-type electrolyte material. The invention further provides liquid or gel-type electrochemical cells having improved durability having a pair of electrodes, a pair of ion insertion layers sandwiched between the pair of electrodes, a pair of solid ion conducting layers sandwiched between the ion insertion layers, and a liquid or gel-type electrolyte material disposed between the solid ion conducting layers, where the solid ion conducting layer minimizes or prevents degradation of the faces of the ion insertion materials facing the liquid or gel-type electrolyte material. Electrochemical cells of this invention having increased durability include secondary lithium batteries and electrochromic devices.

  13. Small genomic insertions form enhancers that misregulate oncogenes

    PubMed Central

    Abraham, Brian J.; Hnisz, Denes; Weintraub, Abraham S.; Kwiatkowski, Nicholas; Li, Charles H.; Li, Zhaodong; Weichert-Leahey, Nina; Rahman, Sunniyat; Liu, Yu; Etchin, Julia; Li, Benshang; Shen, Shuhong; Lee, Tong Ihn; Zhang, Jinghui; Look, A. Thomas; Mansour, Marc R.; Young, Richard A.

    2017-01-01

    The non-coding regions of tumour cell genomes harbour a considerable fraction of total DNA sequence variation, but the functional contribution of these variants to tumorigenesis is ill-defined. Among these non-coding variants, somatic insertions are among the least well characterized due to challenges with interpreting short-read DNA sequences. Here, using a combination of Chip-seq to enrich enhancer DNA and a computational approach with multiple DNA alignment procedures, we identify enhancer-associated small insertion variants. Among the 102 tumour cell genomes we analyse, small insertions are frequently observed in enhancer DNA sequences near known oncogenes. Further study of one insertion, somatically acquired in primary leukaemia tumour genomes, reveals that it nucleates formation of an active enhancer that drives expression of the LMO2 oncogene. The approach described here to identify enhancer-associated small insertion variants provides a foundation for further study of these abnormalities across human cancers. PMID:28181482

  14. Histological analysis of the tibial anterior cruciate ligament insertion.

    PubMed

    Oka, Shinya; Schuhmacher, Peter; Brehmer, Axel; Traut, Ulrike; Kirsch, Joachim; Siebold, Rainer

    2016-03-01

    This study was performed to investigate the morphology of the tibial anterior cruciate ligament (ACL) by histological assessment. The native (undissected) tibial ACL insertion of six fresh-frozen cadaveric knees was cut into four sagittal sections parallel to the long axis of the medial tibial spine. For histological evaluation, the slices were stained with haematoxylin and eosin, Safranin O and Russell-Movat pentachrome. All slices were digitalized and analysed at a magnification of 20×. The anterior tibial ACL insertion was bordered by a bony anterior ridge. The most medial ACL fibres inserted from the medial tibial spine and were adjacent to the articular cartilage of the medial tibial plateau. Parts of the bony insertions of the anterior and posterior horns of the lateral meniscus were in close contact with the lateral part of the tibial ACL insertion. A small fat pad was located just posterior to the functional ACL fibres. The anterior-posterior length of the medial ACL insertion was an average of 10.8 ± 1.1 mm compared with the lateral, which was only 6.2 ± 1.1 mm (p < 0.001). There were no central or posterolateral inserting ACL fibres. The shape of the bony tibial ACL insertion was 'duck-foot-like'. In contrast to previous findings, the functional mid-substance fibres arose from the most posterior part of the 'duck-foot' in a flat and 'c-shaped' way. The most anterior part of the tibial ACL insertion was bordered by a bony anterior ridge and the most medial by the medial tibial spine. No posterolateral fibres nor ACL bundles have been found histologically. This histological investigation may improve our understanding of the tibial ACL insertion and may provide important information for anatomical ACL reconstruction.

  15. [Advantages and disadvantages of IUD insertion immediately after abortion].

    PubMed

    Matrljan, I; Randić, L

    1982-01-01

    In 672 women the interval insertion of intrauterine contraception devices (IUD) was applied: Lippes loop D in 138 women. In 530 women the insertion was applied immediately after artificial abortion: Lippes loop C in 390 and Lippes loop D in 140 cases. Data on the effectiveness of intrauterine contraception were biostatistically treated. One- and two-year gross cumulative rates of pregnancy were 4.4 and 6.4, respectively 3.7 and 6.3 for the interval insertion of Lippes loop C and D, and 2.1 and 4.5, respectively 4.2 and 11.2 for the postabortion insertion of the same devices. Two-year cumulative rates of spontaneous expulsions of 18.5 and 8.1 for interval insertions were significantly higher than in the group of women in whom the insertion of the same devices was performed immediately after abortion and in whom these rates were 11.1 and 5.9. The removal of intrauterine contraception devices because of bleeding and pain, or because of both, with the rates of 6.4 and 3.2 in 100 women after a two-year use, was less frequent in the group of women in whom interval insertion was performed than in the group of postabortion insertions with the corresponding rates of 7.3 and 9.9, respectively. To prevent repeated abortions, a frequent use of postabortion IUD insertion is recommended. Only when an intensified bleeding is expected, it is advisable to postpone insertion at least until the first menstruation.

  16. Modulation of the pHLIP Transmembrane Helix Insertion Pathway

    PubMed Central

    Karabadzhak, Alexander G.; Weerakkody, Dhammika; Wijesinghe, Dayanjali; Thakur, Mak S.; Engelman, Donald M.; Andreev, Oleg A.; Markin, Vladislav S.; Reshetnyak, Yana K.

    2012-01-01

    The membrane-associated folding/unfolding of pH (low) insertion peptide (pHLIP) provides an opportunity to study how sequence variations influence the kinetics and pathway of peptide insertion into bilayers. Here, we present the results of steady-state and kinetics investigations of several pHLIP variants with different numbers of charged residues, with attached polar cargoes at the peptide's membrane-inserting end, and with three single-Trp variants placed at the beginning, middle, and end of the transmembrane helix. Each pHLIP variant exhibits a pH-dependent interaction with a lipid bilayer. Although the number of protonatable residues at the inserting end does not affect the ultimate formation of helical structure across a membrane, it correlates with the time for peptide insertion, the number of intermediate states on the folding pathway, and the rates of unfolding and exit. The presence of polar cargoes at the peptide's inserting end leads to the appearance of intermediate states on the insertion pathway. Cargo polarity correlates with a decrease of the insertion rate. We conclude that the existence of intermediate states on the folding and unfolding pathways is not mandatory and, in the simple case of a polypeptide with a noncharged and nonpolar inserting end, the folding and unfolding appears as an all-or-none transition. We propose a model for membrane-associated insertion/folding and exit/unfolding and discuss the importance of these observations for the design of new delivery agents for direct translocation of polar therapeutic and diagnostic cargo molecules across cellular membranes. PMID:22768940

  17. Postplacental insertion of the levonorgestrel intrauterine device after cesarean delivery vs. delayed insertion: a randomized controlled trial.

    PubMed

    Whitaker, Amy K; Endres, Loraine K; Mistretta, Stephanie Q; Gilliam, Melissa L

    2014-06-01

    This trial was designed to compare levonorgestrel intrauterine device (LNG-IUD) use at 1 year after delivery between women randomized to postplacental insertion at the time of cesarean delivery and delayed insertion 4-8 weeks after delivery. This randomized controlled trial was conducted at two urban medical centers. Eligible pregnant women with planned cesarean deliveries were randomized to immediate postplacental insertion during cesarean or delayed insertion after 4-8 weeks. We used intention-to-treat analysis for the primary outcome of LNG-IUD use 12 months after delivery. Forty-two women were randomized, 20 into the postplacental group and 22 in the delayed group. Although confirmed use of the LNG-IUD 12 months after delivery was higher in the postplacental group (60.0% vs. 40.9%, p=.35), this difference was not statistically significance. Expulsion was significantly more common in the postplacental group (20.0% vs. 0%, p=.04). There were significant differences between the two sites in baseline population characteristics, follow-up and expulsion. The trial did not answer the intended question as it was halted early due to slow enrollment. Our results show higher expulsion after postplacental insertion compared to delayed insertion but suggest similar IUD use at 12 months. Moreover, it provides valuable lessons regarding a randomized controlled trial of postplacental LNG-IUD placement due to the challenges of estimating effect size and the nature of the population who might benefit from immediate insertion. Postplacental insertion of an IUD may improve use of highly effective contraception during the postpartum period. While our results suggest higher expulsion after postplacental insertion compared to delayed insertion and similar IUD use at 12 months, our trial was insufficient to definitively test our hypothesis. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Method of joining a vane cavity insert to a nozzle segment of a gas turbine

    DOEpatents

    Burdgick, Steven Sebastian

    2002-01-01

    An insert containing apertures for impingement cooling a nozzle vane of a nozzle segment in a gas turbine is inserted into one end of the vane. The leading end of the insert is positioned slightly past a rib adjacent the opposite end of the vane through which the insert is inserted. The end of the insert is formed or swaged into conformance with the inner margin of the rib. The insert is then brazed or welded to the rib.

  19. Toward automated cochlear implant insertion using tubular manipulators

    NASA Astrophysics Data System (ADS)

    Granna, Josephine; Rau, Thomas S.; Nguyen, Thien-Dang; Lenarz, Thomas; Majdani, Omid; Burgner-Kahrs, Jessica

    2016-03-01

    During manual cochlear implant electrode insertion the surgeon is at risk to damage the intracochlear fine-structure, as the electrode array is inserted through a small opening in the cochlea blindly with little force-feedback. This paper addresses a novel concept for cochlear electrode insertion using tubular manipulators to reduce risks of causing trauma during insertion and to automate the insertion process. We propose a tubular manipulator incorporated into the electrode array composed of an inner wire within a tube, both elastic and helically shaped. It is our vision to use this manipulator to actuate the initially straight electrode array during insertion into the cochlea by actuation of the wire and tube, i.e. translation and slight axial rotation. In this paper, we evaluate the geometry of the human cochlea in 22 patient datasets in order to derive design requirements for the manipulator. We propose an optimization algorithm to automatically determine the tube set parameters (curvature, torsion, diameter, length) for an ideal final position within the cochlea. To prove our concept, we demonstrate that insertion can be realized in a follow-the-leader fashion for 19 out of 22 cochleas. This is possible with only 4 different tube/wire sets.

  20. Isthmus-guided cortical bone trajectory for pedicle screw insertion.

    PubMed

    Iwatsuki, Koichi; Yoshimine, Toshiki; Ohnishi, Yu-ichiro; Ninomiya, Kosi; Ohkawa, Toshika

    2014-08-01

    Herein is described cortical bone trajectory (CBT), a new path for pedicle screw insertion for lumbar vertebral fusion. Because the points of insertion are under the end of the inferior articular process, and because the screws are inserted toward the lateral side, there is less soft tissue development than with the conventional technique; the CBT technique therefore enables less invasive surgery than the conventional technique. However, it has some drawbacks. For example, in the original CBT approach, the points of insertion are in the vicinity of the end of the inferior articular process. Because this joint has been destroyed in many patients who have indications for intervertebral fusion surgery, it is sometimes difficult to use it as a reference point for screw insertion location. With severe lateral slippage, the screw insertion site can become significantly dislocated sideways, with possible resultant damaging to the spinal canal and/or nerve root. The CBT technique here involved inserting the screws while keeping clear of the intervertebral foramen with the assistance of side view X-ray fluoroscopy and using the end of the inferior articular process and the isthmus as points of reference for screw location.

  1. The genomic landscape of polymorphic human nuclear mitochondrial insertions

    PubMed Central

    Dayama, Gargi; Emery, Sarah B.; Kidd, Jeffrey M.; Mills, Ryan E.

    2014-01-01

    The transfer of mitochondrial genetic material into the nuclear genomes of eukaryotes is a well-established phenomenon that has been previously limited to the study of static reference genomes. The recent advancement of high throughput sequencing has enabled an expanded exploration into the diversity of polymorphic nuclear mitochondrial insertions (NumtS) within human populations. We have developed an approach to discover and genotype novel Numt insertions using whole genome, paired-end sequencing data. We have applied this method to a thousand individuals in 20 populations from the 1000 Genomes Project and other datasets and identified 141 new sites of Numt insertions, extending our current knowledge of existing NumtS by almost 20%. We find that recent Numt insertions are derived from throughout the mitochondrial genome, including the D-loop, and have integration biases that differ in some respects from previous studies on older, fixed NumtS in the reference genome. We determined the complete inserted sequence for a subset of these events and have identified a number of nearly full-length mitochondrial genome insertions into nuclear chromosomes. We further define their age and origin of insertion and present an analysis of their potential impact to ongoing studies of mitochondrial heteroplasmy and disease. PMID:25348406

  2. Immediate post-placental IUD insertion: the expulsion problem.

    PubMed

    Thiery, M; Van Kets, H; Van der Pas, H

    1985-04-01

    This paper reports an evaluation of immediate post-placental insertion of a non-copper (Lippes Loop D) and several copper-bearing IUD models (TCu200, TCu220C, MLCu375, MLCu250, Nova T-PP, DimélysR). Based on the analysis of a total of 2,646 insertions and 55,794 woman-months of experience, we conclude that placement of an IUD within ten minutes of delivery of the placenta is a valuable alternative to interval insertion, because this method is safe and effective. Effectiveness was significantly lower for the Lippes Loop D than for the T- and ML-IUD models tested, the latter showing roughly comparable pertinent event rates. Pertinent event rates for copper IUDs were influenced by the skill of the operator; age of the recipient only had a significant effect on effectiveness, whereas parity had no significant effect on pertinent event rates. The single and still unsolved problem associated with immediate postpartum insertion is the greater likelihood of expulsion compared with interval insertion, and this hazard is significantly much greater for the Loop than for the copper-bearing devices assessed. The evolution of the expulsion rates shows a constant time-relationship. This pattern makes it obvious why follow-up of recipients, at least during the first trimester following insertion, is mandatory if immediate post-placental IUD insertion is to be optimally effective.

  3. Radiation hardness studies of n + -in-n planar pixel sensors for the ATLAS upgrades

    NASA Astrophysics Data System (ADS)

    Altenheiner, S.; Goessling, C.; Jentzsch, J.; Klingenberg, R.; Muenstermann, D.; Rummler, A.; Troska, G.; Wittig, T.

    2011-12-01

    The ATLAS experiment at the LHC is planning upgrades of its pixel detector to cope with the luminosity increase foreseen in the coming years within the transition from LHC to Super-LHC (SLHC/HL-LHC). Associated with the increase in instantaneous luminosity is a rise of the target integrated luminosity from 730 to about 3000 fb -1 which directly translates into significantly higher radiation damage. These upgrades consist of the installation of a 4th pixel layer, the insertable b-layer IBL, with a mean sensor radius of only 32 mm from the beam axis, before 2016/17. In addition, the complete pixel detector will be exchanged before 2020/21. Being very close to the beam, the radiation damage of the IBL sensors might be as high as 5×1015 neq cm-2 at their end-of-life. The total fluence of the innermost pixel layer after the SLHC upgrade might even reach 2×1016 neq cm-2. To investigate the radiation hardness and suitability of the current ATLAS pixel sensors for these fluences, n +-in-n silicon pixel sensors from the ATLAS Pixel production have been irradiated by reactor neutrons to the IBL design fluence and been tested with pions at the SPS and with electrons from a 90Sr source in the laboratory. The collected charge after IBL fluences was found to exceed 10 000 electrons per MIP at 1 kV of bias voltage which is in agreement with data collected with strip sensors. After SLHC fluences, still reliable operation of the devices could be observed with a collected charge of more than 5000 electrons per MIP.

  4. Differential and linear insertion of atrioventricular valves: a useful tool?

    PubMed

    Adriaanse, B M E; Bartelings, M M; van Vugt, J M G; Chaoui, R; Gittenberger-de Groot, A C; Haak, M C

    2014-11-01

    The differential insertion of the atrioventricular valves is the ultrasonographic representation of the more apical attachment of the tricuspid valve to the septum with respect to the mitral valve. A linear insertion is present when both valves form a linear continuum and has been suggested as a marker for atrioventricular septal defects (AVSDs). The objective of this study was to evaluate the anatomical substratum of differential and linear insertions of the atrioventricular valves in normal fetal hearts and fetal hearts with an AVSD. The extent and position of the fibrous skeleton and attachment of the atrioventricular valves to the septum were studied in histological sections of 17 normal hearts and four hearts with an AVSD from 10 + 0 weeks' gestation to 3 days postpartum with various immunohistochemical tissue markers. In addition, spatiotemporal image correlation (STIC) volumes of 10 normal hearts and STIC volumes of eight hearts with an AVSD at 13 + 6 to 35 + 5 weeks' gestation were examined. The differential insertion of the atrioventricular valves was visible in normal hearts in the four-chamber plane immediately beneath the aorta, but nearer the diaphragm a linear insertion was found. In hearts with an AVSD, a linear appearance was observed in the four-chamber plane immediately beneath the aorta. Towards the diaphragm, however, first a differential insertion and, more caudally, a linear insertion was found. Both differential and linear insertions can be found in normal fetal hearts and fetal hearts with AVSD, depending on the plane in which the four-chamber view is visualized. Therefore, measurement of the differential insertion is likely to be useful only in experienced hands. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  5. Industrial stator vane with sequential impingement cooling inserts

    SciTech Connect

    Jones, Russell B; Fedock, John A; Goebel, Gloria E; Krueger, Judson J; Rawlings, Christopher K; Memmen, Robert L

    2013-08-06

    A turbine stator vane for an industrial engine, the vane having two impingement cooling inserts that produce a series of impingement cooling from the pressure side to the suction side of the vane walls. Each insert includes a spar with a row of alternating impingement cooling channels and return air channels extending in a radial direction. Impingement cooling plates cover the two sides of the insert and having rows of impingement cooling holes aligned with the impingement cooling channels and return air openings aligned with the return air channel.

  6. CT fluoroscopic guided insertion of inferior vena cava filters.

    PubMed

    Ignotus, P; Wetton, C; Berry, J

    2006-03-01

    The value and use of inferior vena cava (IVC) filters is well documented and has been growing since the first reported filter placement in 1973 and the first percutaneous insertion in 1982. Access routes now include both jugular veins, both ante-cubital veins and both femoral veins. However, all insertions require some form of imaging, usually fluoroscopy, to identify the location of the filter with respect to the IVC and the renal veins. We describe two cases where the patients' weight was significantly greater than the weight limit of the angiography table, necessitating insertion under CT fluoroscopic guidance.

  7. A Multiple RCC Device for Polygonal Peg Insertion

    NASA Astrophysics Data System (ADS)

    Cheng, Chi-Cheng; Chen, Gin-Shan

    This paper proposes a new passive compliant center device, the Multiple Remote Center Compliance (MRCC), for assembly tasks. The MRCC introduces a new azimuthal compliance over traditional passive compliance mechanisms that can effectively compensate the peg's orientation deviation for polygonal insertions. Besides, a special feature of the adjustable compliance provides capability to overcome the gravity effect. Non-vertical insertions therefore become possible. A spring-supported object in space is also adopted for stability analysis of this compliant device. Actual experimental assembly processes demonstrate promising results on polygonal insertions in both traditional top-down and horizontal directions.

  8. High-frequency threshold measurements using insert earphones.

    PubMed

    Tang, H; Letowski, T

    1992-10-01

    Several recent studies have reported large intersubject variability of high-frequency thresholds measured with circumaural earphones. In the present study, high-frequency thresholds of 10 subjects were measured with circumaural (Sennheiser HD-250) and insert (Etymotic ER-1) earphones at 10, 12, 14, and 16 kHz. Overall results show significantly smaller variability of the threshold data obtained with insert earphones than with circumaural earphones. The above data indicate that insert earphones may be more suitable for high-frequency testing than circumaural earphones.

  9. Mobilizing diversity: transposable element insertions in genetic variation and disease

    PubMed Central

    2010-01-01

    Transposable elements (TEs) comprise a large fraction of mammalian genomes. A number of these elements are actively jumping in our genomes today. As a consequence, these insertions provide a source of genetic variation and, in rare cases, these events cause mutations that lead to disease. Yet, the extent to which these elements impact their host genomes is not completely understood. This review will summarize our current understanding of the mechanisms underlying transposon regulation and the contribution of TE insertions to genetic diversity in the germline and in somatic cells. Finally, traditional methods and emerging technologies for identifying transposon insertions will be considered. PMID:20813032

  10. International Workshop on Magnetic Measurements of Insertion Devices

    SciTech Connect

    Not Available

    1993-10-01

    The International Workshop on Magnetic Measurements of Insertion Devices was held at the Advanced Photon Source, Argonne National Laboratory, on September 28--29, 1993. The workshop brought together scientists and engineers from Europe, Japan, and the United States to discuss the following topics: Special techniques for magnetic measurements of insertion devices, magnetic tolerances of the insertion devices for third generation synchrotron radiation sources, methods for and accuracy of the multipole moments measurements, magnetic sensors, among other topics. The workshop included thirteen presentations that are collected in this volume.

  11. Kinematics Analysis of an Aided Robot for Needle Insertion

    NASA Astrophysics Data System (ADS)

    Li, Qiang; Gao, Dedong; Wang, Shan; Bai, Huiquan; Zheng, Haojun

    The kinematic relationship between the needle base and the robot's joints is analyzed. The analysis process is based on the aided needle-insertion robot built by our group. The thinking of needle-inserting procedure is confirming the needle base's posture before the needle inserted into tissue. The method of Denavit-Hartenberg (D-H) parameters is used to establish a link robot body-frames with the structural characteristics of the robot. After analysing kinematics, the kinematics equation is presented. The kinematics inverse solutions are obtained with the analytical method and geometry analysis method.

  12. Small bowel injury after suprapubic catheter insertion presenting 3 years after initial insertion

    PubMed Central

    Gallagher, Kevin M; Good, Daniel W; Brush, John P; Al-hasso, Ammar; Stewart, Grant D

    2013-01-01

    A 77-year-old woman was referred to urology with blockages of her suprapubic catheter (SPC). The catheter was replaced easily in the emergency department, however, no urine was draining, only a cloudy green fluid was visible. On cystoscopy bilious material was identified in the bladder. There was no catheter visible. There seemed to be a fistulous tract entering the bladder at the left dome. The urethra was dilated, a urethral catheter was placed and the SPC was removed. A CT demonstrated that the SPC tract transfixed a loop of pelvic small bowel and entered the bladder with no intraperitoneal contrast leak. The patient recovered well and did not require laparotomy. This case emphasises that bowel perforation, although rare, must be considered as a complication of SPC placement even years after initial insertion when catheter problems arise. Unusually, we learn that this complication may not present with abdominal pain or peritonism. PMID:24326435

  13. Effect of insertion speed on tissue response and insertion mechanics of a chronically implanted silicon-based neural probe.

    PubMed

    Welkenhuysen, M; Andrei, A; Ameye, L; Eberle, W; Nuttin, B

    2011-11-01

    In this study, the effect of insertion speed on long-term tissue response and insertion mechanics was investigated. A dummy silicon parylene-coated probe was used in this context and implanted in the rat brain at 10 μm/s (n = 6) or 100 μm/s (n = 6) to a depth of 9 mm. The insertion mechanics were assessed by the dimpling distance, and the force at the point of penetration, at the end of the insertion phase, and after a 3-min rest period in the brain. After 6 weeks, the tissue response was evaluated by estimating the amount of gliosis, inflammation, and neuronal cell loss with immunohistochemistry. No difference in dimpling, penetration force, or the force after a 3-min rest period in the brain was observed. However, the force at the end of the insertion phase was significantly higher when inserting the probes at 100 μm/s compared to 10 μm/s. Furthermore, an expected tissue response was seen with an increase of glial and microglial reactivity around the probe. This reaction was similar along the entire length of the probe. However, evidence for a neuronal kill zone was observed only in the most superficial part of the implant. In this region, the lesion size was also greatest. Comparison of the tissue response between insertion speeds showed no differences.

  14. The accuracy and the safety of individualized 3D printing screws insertion templates for cervical screw insertion.

    PubMed

    Deng, Ting; Jiang, Minghui; Lei, Qing; Cai, Lihong; Chen, Li

    2016-12-01

    Clinical trial for cervical screw insertion by using individualized 3-dimensional (3D) printing screw insertion templates device. The objective of this study is to evaluate the safety and accuracy of the individualized 3D printing screw insertion template in the cervical spine. Ten patients who underwent posterior cervical fusion surgery with cervical pedicle screws, laminar screws or lateral mass screws between December 2014 and December 2015 were involved in this study. The patients were examined by CT scan before operation. The individualized 3D printing templates were made with photosensitive resin by a 3D printing system to ensure the screw shafts entered the vertebral body without breaking the pedicle or lamina cortex. The templates were sterilized by a plasma sterilizer and used during the operation. The accuracy and the safety of the templates were evaluated by CT scans at the screw insertion levels after operation. The accuracy of this patient-specific template technique was demonstrated. Only one screw axis greatly deviated from the planned track and breached the cortex of the pedicle because the template was split by rough handling and then we inserted the screws under the fluoroscopy. The remaining screws were inserted in the track as preoperative design and the screw axis deviated by less than 2 mm. Vascular or neurologic complications or injuries did not happen. And no infection, broken nails, fracture of bone structure, or screw pullout occurred. This study verified the safety and the accuracy of the individualized 3D printing screw insertion templates in the cervical spine as a kind of intraoperative screw navigation. This individualized 3D printing screw insertion template was user-friendly, moderate cost, and enabled a radiation-free cervical screw insertion.

  15. Wireless cardiac action potential transmission with ultrasonically inserted silicon microprobes

    NASA Astrophysics Data System (ADS)

    Shen, C. J.; Ramkumar, A.; Lal, A.; Gilmour, R. F., Jr.

    2011-05-01

    This paper reports on the integration of ultrasonically inserted horn-shaped cardiac probes with wireless transmission of 3D cardiac action potential measurement for applications in ex vivo preparations such as monitoring the onset of ventricular fibrillation. Ultrasonically inserted silicon horn probes permit reduced penetration force during insertion, allowing silicon, a brittle material, to penetrate cardiac tissue. The probes also allow recording from multiple sites that are lithographically defined. An application-specific integrated circuit has been designed with a 40 dB amplifying stage and a frequency modulating oscillator at 95 MHz to wirelessly transmit the recorded action potentials. This ultrasonically inserted microprobe wireless system demonstrates the initial results in wireless monitoring of 3D action potential propagation, and the extraction of parameters of interest including the action potential duration and diastolic interval.

  16. Bougie insertion: A common practice with underestimated dangers

    PubMed Central

    Theodorou, D.; Doulami, G.; Larentzakis, A.; Almpanopoulos, K.; Stamou, K.; Zografos, G.; Menenakos, E.

    2011-01-01

    Introduction Esophageal perforation after bariatric operations is rare. We report two cases of esophageal perforation after bariatric operations indicating the dangers of a common practice – like insertion of esophageal tubes – and we describe our management of that complication. Presentation of case A 56 year old woman who underwent laparoscopic sleeve gastrectomy and a 41 year old woman who underwent laparoscopic adjustable gastric banding respectively. In both operations a bougie has been used and led to esophageal perforation. Discussion The insertion of bougie and especially of inflated bougie is a common practice. It is an invasive procedure that in most cases is performed by the anesthesiologist team. Conclusion Bougie insertion is an invasive procedure with risks and should always be attempted under direct supervision of surgical team or should be inserted by a surgeon. PMID:22288051

  17. Membrane protein insertion: mixing eukaryotic and prokaryotic concepts.

    PubMed

    Schleiff, Enrico; Soll, Jürgen

    2005-11-01

    Proteins are translocated across or inserted into membranes by machines that are composed of soluble and membrane-anchored subunits. The molecular action of these machines and their evolutionary origin are at present the focus of intense research. For instance, our understanding of the mode of insertion of beta-barrel membrane proteins into the outer membrane of endosymbiotically derived organelles has increased rapidly during the past few years. In particular, the identification of the Omp85/YaeT-involving pathways in Neisseria meningitidis, Escherichia coli and cyanobacteria, and homologues of Omp85/YaeT in chloroplasts and mitochondria, has provided new clues about the ancestral beta-barrel protein insertion pathway. This review focuses on recent advances in the elucidation of the evolutionarily conserved concepts that underlie the translocation and insertion of beta-barrel membrane proteins.

  18. Spontaneous Radiation Emission from Short, High Field Strength Insertion Devices

    SciTech Connect

    Geoffrey Krafft

    2005-09-15

    Since the earliest papers on undulaters were published, it has been known how to calculate the spontaneous emission spectrum from ''short'' undulaters when the magnetic field strength parameter is small compared to unity, or in ''single'' frequency sinusoidal undulaters where the magnetic field strength parameter is comparable to or larger than unity, but where the magnetic field amplitude is constant throughout the undulater. Fewer general results have been obtained in the case where the insertion device is both short, i.e., the magnetic field strength parameter changes appreciably throughout the insertion device, and the magnetic field strength is high enough that ponderomotive effects, radiation retardation, and harmonic generation are important physical phenomena. In this paper a general method is presented for calculating the radiation spectrum for short, high-field insertion devices. It is used to calculate the emission from some insertion device designs of recent interest.

  19. The use of dimorphic Alu insertions in human DNA fingerprinting

    SciTech Connect

    Novick, G.E.; Gonzalez, T.; Garrison, J.; Novick, C.C.; Herrera, R.J.; Batzer, M.A.; Deininger, P.L.

    1992-12-04

    We have characterized certain Human Specific Alu Insertions as either dimorphic (TPA25, PV92, APO), sightly dimorphic (C2N4 and C4N4) or monomorphic (C3N1, C4N6, C4N2, C4N5, C4N8), based on studies of Caucasian, Asian, American Black and African Black populations. Our approach is based upon: (1) PCR amplification using primers directed to the sequences that flank the site of insertion of the different Alu elements studied; (2) gel electrophoresis and scoring according to the presence or absence of an Alu insertion in one or both homologous chromosomes; (3) allelic frequencies calculated and compared according to Hardy-Weinberg equilibrium. Our DNA fingerprinting procedure using PCR amplification of dimorphic Human Specific Alu insertions, is stable enough to be used not only as a tool for genetic mapping but also to characterize populations, study migrational patterns and track the inheritance of human genetic disorders.

  20. Effect of "Megafiller" insertion on the wear of composite resins.

    PubMed

    Tani, Y; Togaya, T; Ishikawa, A; Watanabe, Y; Maruyama, K; Katsuyama, S

    1994-12-01

    We have previously reported that insertion of coarse particles of beta-Quartz Glass Ceramic Insert (Megafiller) into a composite resin markedly reduced the polymerization shrinkage of resin restorative materials. In this study, we examined the effects of Megafiller insertion on wear resistance evaluated by the glass beads abrasion test, and the conventional toothbrushing abrasion test. The depth of wear was determined by measuring the thickness of the specimen before and after the wear tests using a profile projector accurate to 1 micron. In general, the depth of wear of the composites was reduced by Megafiller insertion, but the differences in the depth of wear between composites with and without the Megafiller were not significant except for a few materials. There were slight differences in the wetness of Megafiller in some composite resins.

  1. Training on hearing protector insertion improves noise attenuation.

    PubMed

    Samelli, Alessandra Giannella; Rocha, Clayton Henrique; Theodósio, Patrícia; Moreira, Renata Rodrigues; Neves-Lobo, Ivone Ferreira

    2015-01-01

    To determine the efficacy of hearing protector insertion by comparing attenuation values measured by objective (MIRE) and subjective (REAT) methods in groups with and without training. The study included 80 male subjects assigned to experimental (with training) and control (without training) groups. The following procedures were performed: occupational history, objective and subjective assessment of hearing protectors. Only subjects in the experimental group received training and guidance on proper hearing protector insertion. Attenuation values were significantly higher in the experimental group than in the control group at all frequencies (500, 1000, 2000, and 4000 Hz) investigated through the objective (MIRE) and subjective (REAT) methods. In addition, attenuation values in the control group were lower than those provided by the hearing protector manufacturer. Both objective and subjective attenuation tests demonstrated the efficacy of training on insertion of hearing protectors because the group that received training on proper hearing protection insertion exhibited higher attenuation values than the untrained group.

  2. Development of Magnet Technologies for HTS Insert Coils

    NASA Astrophysics Data System (ADS)

    Wesche, Rainer; Uglietti, Davide; Bruzzone, Pierluigi; March, Stephen; Marinucci, Claudio; Stepanov, Boris; Glowa, Natalia

    An existing Nb3Sn laboratory magnet generating a magnetic field of 12 T is intended to be upgraded to 16 T by means of the use of a high temperature superconductor (HTS) insert coil. An outline design of the HTS insert coil is presented. In the design, the aspects of the maximum achievable operation current, the required copper cross-section to ensure a hot spot temperature below 200 K and the resulting forces and stresses have been considered. The length of the insert coil has been selected in such a way that the field uniformity will be better than 1% within a sphere of 3 cm diameter. The protection of the whole magnet system (LTS & HTS insert) is briefly described.

  3. 33. Launch Control Center, close view of launch key inserted ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. Launch Control Center, close view of launch key inserted in the launch panel. Lyon - Whiteman Air Force Base, Oscar O-1 Minuteman Missile Alert Facility, Southeast corner of Twelfth & Vendenberg Avenues, Knob Noster, Johnson County, MO

  4. Use of a Nasal Speculum for Chest-Drain Insertion

    PubMed Central

    Saxena, Pankaj; Konstantinov, Igor E.; Newman, Mark A.J.

    2006-01-01

    Tube thoracostomy is a very commonly performed procedure in cardiothoracic surgery. Insertion of a chest drain requires expertise to minimize complications. We describe a simple technique of using a nasal speculum to perform this procedure. PMID:17041709

  5. Pressure molding of powdered materials improved by rubber mold insert

    NASA Technical Reports Server (NTRS)

    1964-01-01

    Pressure molding tungsten microspheres is accomplished by applying hydraulic pressure to a silicone rubber mold insert with several barrel shaped chambers which is placed in a steel die cavity. This technique eliminates castings containing shear fractures.

  6. Marshburn prepares to insert biological samples in the MELFI-1

    NASA Image and Video Library

    2013-01-07

    ISS034-E-026607 (7 Jan. 2013) --- NASA astronaut Tom Marshburn, Expedition 34 flight engineer, prepares to insert biological samples in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.

  7. FE Williams inserts Biological Samples into the MELFI-2

    NASA Image and Video Library

    2012-08-02

    ISS032-E-011639 (2 Aug. 2012) --- NASA astronaut Sunita Williams, Expedition 32 flight engineer, prepares to insert biological samples in the Minus Eighty Laboratory Freezer for ISS-2 (MELFI-2) in the Destiny laboratory of the International Space Station.

  8. Interior, detail closeup shot of window with stained glass inserts ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior, detail closeup shot of window with stained glass inserts in top southeast room taken from ther west - J. Weingartner & Son Cigar Factory, 414 East Walnut Street, North Wales, Montgomery County, PA

  9. Fireplace insert and its parameters depend on the used glazing

    NASA Astrophysics Data System (ADS)

    Papučík, Štefan; Čaja, Alexander

    2016-06-01

    The contribution deals with the analysis of the impact of using double glass to change the performance and emission parameters of the fireplace insert. Conventional fireplace inserts are equipped with heat-resistant glass, which is resistant to high temperatures. For this type of inserts are required to be radiant constituent maximized. Prevailing part of heat is into the interior gets just by radiation through the glazed part. The hot water fireplace inserts is the requirement that the radiant constituent to the environment to a minimum. Therefore, instead of a single glass using double glazing which is intended to reduce this part of heat transfer. The temperature in the furnace is increased, and transmitted most of the heat into the water.

  10. Shoe inserts and orthotics for sport and physical activities.

    PubMed

    Nigg, B M; Nurse, M A; Stefanyshyn, D J

    1999-07-01

    The purposes of this paper were to discuss the perceived benefits of inserts and orthotics for sport activities and to propose a new concept for inserts and orthotics. There is evidence that inserts or orthotics reduce or prevent movement-related injuries. However, there is limited knowledge about the specific functioning an orthotic or insert provides. The same orthotic or insert is often proposed for different problems. Changes in skeletal movement due to inserts or orthotics seem to be small and not systematic. Based on the results of a study using bone pins, one may question the idea that a major function of orthotics or inserts consists in aligning the skeleton. Impact cushioning with shoe inserts or orthotics is typically below 10%. Such small reductions might not be important for injury reduction. It has been suggested that changes in material properties might produce adjustments in the muscular response of the locomotor system. The foot has various sensors to detect input signals with subject specific thresholds. Subjects with similar sensitivity threshold levels seem to respond in their movement pattern in a similar way. Comfort is an important variable. From a biomechanical point of view, comfort may be related to fit, additional stabilizing muscle work, fatigue, and damping of soft tissue vibrations. Based on the presented evidence, the concept of minimizing muscle work is proposed when using orthotics or inserts. A force signal acts as an input variable on the shoe. The shoe sole acts as a first filter, the insert or orthotic as a second filter, the plantar surface of the foot as a third filter for the force input signal. The filtered information is transferred to the central nervous system that provides a subject specific dynamic response. The subject performs the movement for the task at hand. For a given movement task, the skeleton has a preferred path. If an intervention supports/counteracts the preferred movement path, muscle activity can/must be

  11. Evolution models with base substitutions, insertions, deletions, and selection

    NASA Astrophysics Data System (ADS)

    Saakian, D. B.

    2008-12-01

    The evolution model with parallel mutation-selection scheme is solved for the case when selection is accompanied by base substitutions, insertions, and deletions. The fitness is assumed to be either a single-peak function (i.e., having one finite discontinuity) or a smooth function of the Hamming distance from the reference sequence. The mean fitness is calculated exactly in large-genome limit. In the case of insertions and deletions the evolution characteristics depend on the choice of reference sequence.

  12. Mechanism for electrochemical hydrogen insertion in carbonaceous materials

    NASA Astrophysics Data System (ADS)

    Qu, Deyang

    The mechanism for safe and reversible storage of hydrogen in porous carbonaceous materials by electrochemical decomposition of water in alkaline electrolyte is proposed. Atomic H was found to be inserted into the microdomains of defective graphene layers. Hydrogen storage capacity increases with increasing interlayer distance between carbon sheets. Hydrogen insertion in carbonaceous materials occurs at ambient conditions. Static potential acts as an electrochemical valve which can retain the hydrogen in the carbon structure, thus preventing leakage during storage.

  13. Evaluation of preferable insertion routes for esophagogastroduodenoscopy using ultrathin endoscopes

    PubMed Central

    Ono, Satoshi; Niimi, Keiko; Fujishiro, Mitsuhiro; Takahashi, Yu; Sakaguchi, Yoshiki; Nakayama, Chiemi; Minatsuki, Chihiro; Matsuda, Rie; Hirayama-Asada, Itsuko; Tsuji, Yosuke; Mochizuki, Satoshi; Kodashima, Shinya; Yamamichi, Nobutake; Ozeki, Atsuko; Matsumoto, Lumine; Ohike, Yumiko; Yamazaki, Tsutomu; Koike, Kazuhiko

    2014-01-01

    AIM: To evaluate the discomfort associated with esophagogastroduodenoscopy (EGD) using an ultrathin endoscope through different insertion routes. METHODS: This study (January 2012-March 2013) included 1971 consecutive patients [male/female (M/F), 1158/813, 57.5 ± 11.9 years] who visited a single institute for annual health checkups. Transnasal EGD was performed in 1394 patients and transoral EGD in 577. EGD-associated discomfort was assessed using a visual analog scale score (VAS score: 0-10). RESULTS: Multivariate analysis revealed gender (M vs F: 4.02 ± 2.15 vs 5.06 ± 2.43) as the only independent predictor of the VAS score in 180 patients who underwent EGD for the first time; whereas it revealed gender (M vs F 3.60 ± 2.20 vs 4.84 ± 2.37), operator, age group (A: < 39 years; B: 40-49 years; C: 50-59 years; D: 60-69 years; E: > 70 years; A/B/C/D/E: 4.99 ± 2.32/4.34 ± 2.49/4.19 ± 2.31/3.99 ± 2.27/3.63 ± 2.31), and type of insertion as independent predictors in the remaining patients. Subanalysis for gender, age group, and insertion route revealed that the VAS score decreased with age regardless of gender and insertion route, was high in female patients regardless of age and insertion route, and was low in males aged over 60 years who underwent transoral insertion. CONCLUSION: Although comprehensive analysis revealed that the insertion route may not be an independent predictor of the VAS score, transoral insertion may reduce EGD-associated discomfort in elderly patients. PMID:24803817

  14. Impediments to rapid insertion of innovative displays and peripherals

    NASA Astrophysics Data System (ADS)

    Nicholson, Gail

    2012-06-01

    In order to optimize system performance and minimize cost for a system to fill capability gaps, an improvement to rapid insertion of innovative display and peripheral technology is required to take advantage of human-machine intersections. Current approaches to testing and integration impedes successful rapid insertion of innovative technology for new systems and incremental upgrades. Considerations to innovative displays and peripherals must occur further to the left of the lifecycle to be successful and key integration areas must be address for success.

  15. MTR MAIN FLOOR. MEN DEMONSTRATE INSERTION OF DUMMY PLUG INTO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MTR MAIN FLOOR. MEN DEMONSTRATE INSERTION OF DUMMY PLUG INTO AN MTR BEAM HOLE. ONE MAN CHECKS RADIATION LEVEL AT THE END OF THE UNIVERSAL COFFIN, WHILE ANOTHER USES TOOL TO INSERT PLUG INTO HOLE THROUGH COFFIN. MEN WEAR "ANTI-C" (ANTI-CONTAMINATION) CLOTHING. INL NEGATIVE NO. 6198. R.G. Larsen, Photographer, 6/27/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  16. Tube Thoracostomy: Increased angle of insertion is associated with complications

    PubMed Central

    Hernandez, Matthew C.; Laan, Danuel V.; Zimmerman, Stacey; Naik, Nimesh D.; Schiller, Henry J.; Aho, Johnathon M.

    2016-01-01

    Introduction Tube thoracostomy (TT), considered a routine procedure, has significant complications. Current recommendations for placement rely on surface anatomy. There is no information to guide operators regarding angle of insertion relative to chest wall. We aim to determine if angle of insertion is associated with complications of TT. Methods We performed a retrospective review of adult trauma patients who necessitated TT at a level I trauma center over a 2 year period (January 2012 – December 2013). TT performed intraoperatively or using radiological guidance were excluded. Thoracic anteroposterior (AP) or posteroanterior (PA) radiographs were reviewed to determine the angle of insertion of TT relative to the thoracic wall. A previously validated classification method was utilized to categorize complications. Descriptive and univariate statistics were used to compare angle of insertion and complicated vs uncomplicated TT. Results Review identified 154 patients who underwent a total of 246 TT placed for emergent trauma. All patients had a post-procedural chest x-ray. We identified 90 complications (37%) over the study period. 144 of the TT’s reviewed had an angle of insertion less than 45 degrees of which there were 27 complications (19%). 102 of the TT’s had an angle greater than 45 degrees and 63 complications (62%), P<0.0001. Conclusions Tube thoracostomy insertion is inherently dangerous. Placement of TT using a higher angle of insertion greater than 45 degrees is associated with increased complications. Further prospective studies quantifying TT angle of insertion on outcomes are needed. Level of Evidence Level IV therapeutic study. PMID:27120327

  17. Gastrostomy tube insertion in children: The Edmonton experience

    PubMed Central

    Ackroyd, Ryan; Saincher, Meghana; Cheng, Simon; El-Matary, Wael

    2011-01-01

    BACKGROUND: Although gastrostomy tube insertion – whether endoscopic or open – is generally safe, procedure-related complications have been reported. OBJECTIVE: To compare gastrostomy tube insertion-related complications between percutaneous endoscopic gastrostomy and open gastrostomy at a single pediatric centre. METHODS: The charts of children (younger than 17 years of age at the time of tube insertion) who underwent endoscopic or open gastrostomy tube insertion from January 2005 to December 2007 at the Stollery Children’s Hospital (Edmonton, Alberta) were examined. RESULTS: A total of 298 children underwent gastrostomy tube insertion over a period of three years. After excluding patients with incomplete charts, 160 children (91 boys, mean [± SD] age 3.18±4.73 years) were included. Eighty-five children (mean age 4.50±5.40 years) had their gastrostomy tube inserted endoscopically, while the remaining 75 (mean age 1.68±3.27 years; P<0.001) underwent an open procedure. The overall rate of major complications was 10.2% for the endoscopic technique and 8.6% for the open technique (P=0.1). Major infections were higher in the endoscopic technique group, while persistent gastrocutaneous fistulas after tube removal were more common in the open technique group. CONCLUSION: Although the rate of major complications was similar between the endoscopic and open tube insertion groups, major infections were more common among children who underwent endoscopic gastrostomy. The decision for gastrostomy tube insertion was primarily based on clinical background. PMID:21647461

  18. Metal-Matrix Composite Parts With Metal Inserts

    NASA Technical Reports Server (NTRS)

    Majkowski, T.; Kashalikar, U.

    1995-01-01

    Developmental fabrication process produces metal-matrix composite (MMC) parts with integral metal inserts. With inserts, MMC parts readily joined to similar parts by use of brazing, welding, or mechanical fasteners. Process conceived to make strong, lightweight components of structures erected in outer space. Also useful on Earth, in such automotive parts as rocker arms, cylinder liners, and pistons. Potential industrial applications include parts subjected to high stresses at high temperatures, as in power-generation, mining, and oil-drilling equipment.

  19. Membrane Insertion Profiles of Peptides Probed by Molecular Dynamics Simulations

    DTIC Science & Technology

    2008-07-17

    membrane-insertion process. Structure and dynamics of membrane- bound peptides have been partly investigated experimentally with carefully designed small...been experimentally determined [6], and characterizing large conformational changes of small, membrane- bound peptides during the membrane-insertion...solid- state NMR techniques [22], were prepared after brief energy minimizations. A time step of 2 fs has been used in the MD simulations. Langevin

  20. Seamless Insertion of Pulmonary Nodules in Chest CT Images

    PubMed Central

    Pezeshk, Aria; Sahiner, Berkman; Zeng, Rongping; Wunderlich, Adam; Chen, Weijie; Petrick, Nicholas

    2017-01-01

    The availability of large medical image datasets is critical in many applications such as training and testing of computer aided diagnosis (CAD) systems, evaluation of segmentation algorithms, and conducting perceptual studies. However, collection of data and establishment of ground truth for medical images are both costly and difficult. To address this problem, we are developing an image blending tool that allows users to modify or supplement existing datasets by seamlessly inserting a lesion extracted from a source image into a target image. In this study we focus on the application of this tool to pulmonary nodules in chest CT exams. We minimize the impact of user skill on the perceived quality of the composite image by limiting user involvement to two simple steps: the user first draws a casual boundary around a nodule in the source, and then selects the center of desired insertion area in the target. We demonstrate the performance of our system on clinical samples, and report the results of a reader study evaluating the realism of inserted nodules compared to clinical nodules. We further evaluate our image blending techniques using phantoms simulated under different noise levels and reconstruction filters. Specifically, we compute the area under the ROC curve (AUC) of the Hotelling observer (HO) and noise power spectrum (NPS) of regions of interest enclosing native and inserted nodules, and compare the detectability, noise texture, and noise magnitude of inserted and native nodules. Our results indicate the viability of our approach for insertion of pulmonary nodules in clinical CT images. PMID:26080378

  1. Templated sequence insertion polymorphisms in the human genome

    NASA Astrophysics Data System (ADS)

    Onozawa, Masahiro; Aplan, Peter

    2016-11-01

    Templated Sequence Insertion Polymorphism (TSIP) is a recently described form of polymorphism recognized in the human genome, in which a sequence that is templated from a distant genomic region is inserted into the genome, seemingly at random. TSIPs can be grouped into two classes based on nucleotide sequence features at the insertion junctions; Class 1 TSIPs show features of insertions that are mediated via the LINE-1 ORF2 protein, including 1) target-site duplication (TSD), 2) polyadenylation 10-30 nucleotides downstream of a “cryptic” polyadenylation signal, and 3) preference for insertion at a 5’-TTTT/A-3’ sequence. In contrast, class 2 TSIPs show features consistent with repair of a DNA double-strand break via insertion of a DNA “patch” that is derived from a distant genomic region. Survey of a large number of normal human volunteers demonstrates that most individuals have 25-30 TSIPs, and that these TSIPs track with specific geographic regions. Similar to other forms of human polymorphism, we suspect that these TSIPs may be important for the generation of human diversity and genetic diseases.

  2. Evaluation of a high resolution silicon PET insert module

    NASA Astrophysics Data System (ADS)

    Grkovski, Milan; Brzezinski, Karol; Cindro, Vladimir; Clinthorne, Neal H.; Kagan, Harris; Lacasta, Carlos; Mikuž, Marko; Solaz, Carles; Studen, Andrej; Weilhammer, Peter; Žontar, Dejan

    2015-07-01

    Conventional PET systems can be augmented with additional detectors placed in close proximity of the region of interest. We developed a high resolution PET insert module to evaluate the added benefit of such a combination. The insert module consists of two back-to-back 1 mm thick silicon sensors, each segmented into 1040 1 mm2 pads arranged in a 40 by 26 array. A set of 16 VATAGP7.1 ASICs and a custom assembled data acquisition board were used to read out the signal from the insert module. Data were acquired in slice (2D) geometry with a Jaszczak phantom (rod diameters of 1.2-4.8 mm) filled with 18F-FDG and the images were reconstructed with ML-EM method. Both data with full and limited angular coverage from the insert module were considered and three types of coincidence events were combined. The ratio of high-resolution data that substantially improves quality of the reconstructed image for the region near the surface of the insert module was estimated to be about 4%. Results from our previous studies suggest that such ratio could be achieved at a moderate technological expense by using an equivalent of two insert modules (an effective sensor thickness of 4 mm).

  3. Sensorless motion planning for medical needle insertion in deformable tissues.

    PubMed

    Alterovitz, Ron; Goldberg, Kenneth Y; Pouliot, Jean; Hsu, I-Chow Joe

    2009-03-01

    Minimally invasive medical procedures such as biopsies, anesthesia drug injections, and brachytherapy cancer treatments require inserting a needle to a specific target inside soft tissues. This is difficult because needle insertion displaces and deforms the surrounding soft tissues causing the target to move during the procedure. To facilitate physician training and preoperative planning for these procedures, we develop a needle insertion motion planning system based on an interactive simulation of needle insertion in deformable tissues and numerical optimization to reduce placement error. We describe a 2-D physically based, dynamic simulation of needle insertion that uses a finite-element model of deformable soft tissues and models needle cutting and frictional forces along the needle shaft. The simulation offers guarantees on simulation stability for mesh modifications and achieves interactive, real-time performance on a standard PC. Using texture mapping, the simulation provides visualization comparable to ultrasound images that the physician would see during the procedure. We use the simulation as a component of a sensorless planning algorithm that uses numerical optimization to compute needle insertion offsets that compensate for tissue deformations. We apply the method to radioactive seed implantation during permanent seed prostate brachytherapy to minimize seed placement error.

  4. Polyubiquitin insertions and the phylogeny of Cercozoa and Rhizaria.

    PubMed

    Bass, David; Moreira, David; López-García, Purificación; Polet, Stephane; Chao, Ema E; von der Heyden, Sophie; Pawlowski, Jan; Cavalier-Smith, Thomas

    2005-08-01

    A single or double amino acid insertion at the monomer-monomer junction of the universal eukaryotic protein polyubiquitin is unique to Cercozoa and Foraminifera, closely related 'core' phyla in the protozoan infrakingdom Rhizaria. We screened 11 other candidate rhizarians for this insertion: Radiozoa (polycystine and acantharean radiolaria), a 'microheliozoan', and Apusozoa; all lack it, supporting suggestions that Foraminifera are more closely related to Cercozoa than either is to other eukaryotes. The insertion's size was ascertained for 12 additional Cercozoa to help resolve their basal branching order. The earliest branching Cercozoa generally have a single amino acid insertion, like all Foraminifera, but a large derived clade consisting of all Monadofilosa except Metopion, Helk-esimastix, and Cercobodo agilis has two amino acids, suggesting one doubling event and no reversions to a single amino acid. Metromonas and Sainouron, cercozoans of uncertain position, have a double insertion, suggesting that they belong in Monadofilosa. An alternative interpretation, suggested by the higher positions for Metopion and Cercobodo on Bayesian trees compared with most distance trees, cannot be ruled out, i.e. that the second insertion took place earlier, in the ancestral filosan, and was followed by three independent reversions to a single amino acid in Chlorarachnea, Metopion and Cercobodo.

  5. Sensorless Motion Planning for Medical Needle Insertion in Deformable Tissues

    PubMed Central

    Alterovitz, Ron; Goldberg, Kenneth Y.; Pouliot, Jean; Hsu, I-Chow

    2009-01-01

    Minimally invasive medical procedures such as biopsies, anesthesia drug injections, and brachytherapy cancer treatments require inserting a needle to a specific target inside soft tissues. This is difficult because needle insertion displaces and deforms the surrounding soft tissues causing the target to move during the procedure. To facilitate physician training and preoperative planning for these procedures, we develop a needle insertion motion planning system based on an interactive simulation of needle insertion in deformable tissues and numerical optimization to reduce placement error. We describe a 2-D physically based, dynamic simulation of needle insertion that uses a finite-element model of deformable soft tissues and models needle cutting and frictional forces along the needle shaft. The simulation offers guarantees on simulation stability for mesh modications and achieves interactive, real-time performance on a standard PC. Using texture mapping, the simulation provides visualization comparable to ultrasound images that the physician would see during the procedure. We use the simulation as a component of a sensorless planning algorithm that uses numerical optimization to compute needle insertion offsets that compensate for tissue deformations. We apply the method to radioactive seed implantation during permanent seed prostate brachytherapy to minimize seed placement error. PMID:19126473

  6. Templated Sequence Insertion Polymorphisms in the Human Genome

    PubMed Central

    Onozawa, Masahiro; Aplan, Peter D.

    2016-01-01

    Templated Sequence Insertion Polymorphism (TSIP) is a recently described form of polymorphism recognized in the human genome, in which a sequence that is templated from a distant genomic region is inserted into the genome, seemingly at random. TSIPs can be grouped into two classes based on nucleotide sequence features at the insertion junctions; Class 1 TSIPs show features of insertions that are mediated via the LINE-1 ORF2 protein, including (1) target-site duplication (TSD), (2) polyadenylation 10–30 nucleotides downstream of a “cryptic” polyadenylation signal, and (3) preference for insertion at a 5′-TTTT/A-3′ sequence. In contrast, class 2 TSIPs show features consistent with repair of a DNA double-strand break (DSB) via insertion of a DNA “patch” that is derived from a distant genomic region. Survey of a large number of normal human volunteers demonstrates that most individuals have 25–30 TSIPs, and that these TSIPs track with specific geographic regions. Similar to other forms of human polymorphism, we suspect that these TSIPs may be important for the generation of human diversity and genetic diseases. PMID:27900318

  7. Retrotransposon insertions in the clonal evolution of pancreatic ductal adenocarcinoma.

    PubMed

    Rodić, Nemanja; Steranka, Jared P; Makohon-Moore, Alvin; Moyer, Allison; Shen, Peilin; Sharma, Reema; Kohutek, Zachary A; Huang, Cheng Ran; Ahn, Daniel; Mita, Paolo; Taylor, Martin S; Barker, Norman J; Hruban, Ralph H; Iacobuzio-Donahue, Christine A; Boeke, Jef D; Burns, Kathleen H

    2015-09-01

    Pancreatic ductal adenocarcinoma (PDAC) is typically diagnosed after the disease has metastasized; it is among the most lethal forms of cancer. We recently described aberrant expression of an open reading frame 1 protein, ORF1p, encoded by long interspersed element-1 (LINE-1; L1) retrotransposon, in PDAC. To test whether LINE-1 expression leads to somatic insertions of this mobile DNA, we used a targeted method to sequence LINE-1 insertion sites in matched PDAC and normal samples. We found evidence of 465 somatic LINE-1 insertions in 20 PDAC genomes, which were absent from corresponding normal samples. In cases in which matched normal tissue, primary PDAC and metastatic disease sites were available, insertions were found in primary and metastatic tissues in differing proportions. Two adenocarcinomas secondarily involving the pancreas, but originating in the stomach and duodenum, acquired insertions with a similar discordance between primary and metastatic sites. Together, our findings show that LINE-1 contributes to the genetic evolution of PDAC and suggest that somatic insertions are acquired discontinuously in gastrointestinal neoplasms.

  8. Embryonic Lethals and T-DNA Insertional Mutagenesis in Arabidopsis.

    PubMed Central

    Errampalli, D; Patton, D; Castle, L; Mickelson, L; Hansen, K; Schnall, J; Feldmann, K; Meinke, D

    1991-01-01

    T-DNA insertional mutagenesis represents a promising approach to the molecular isolation of genes with essential functions during plant embryo development. We describe in this report the isolation and characterization of 18 mutants of Arabidopsis thaliana defective in embryo development following seed transformation with Agrobacterium tumefaciens. Random T-DNA insertion was expected to result in a high frequency of recessive embryonic lethals because many target genes are required for embryogenesis. The cointegrate Ti plasmid used in these experiments contained the nopaline synthase and neomycin phosphotransferase gene markers. Nopaline assays and resistance to kanamycin were used to estimate the number of functional inserts present in segregating families. Nine families appeared to contain a T-DNA insert either within or adjacent to the mutant gene. Eight families were clearly not tagged with a functional insert and appeared instead to contain mutations induced during the transformation process. DNA gel blot hybridization with internal and right border probes revealed a variety of rearrangements associated with T-DNA insertion. A general strategy is presented to simplify the identification of tagged embryonic mutants and facilitate the molecular isolation of genes required for plant embryogenesis. PMID:12324593

  9. [Duration and complications following grommet insertion in childhood].

    PubMed

    Fiebach, A; Matschke, R G

    1987-02-01

    We report 1000 insertions of ventilation tubes in 534 children for secretory otitis media (SOM) within a period of 6 years. In 77.5% of the cases, the air-bone gap was greater than 20 dB. The grommets are allowed to undergo spontaneous expulsion which happened in 319 ears, about 7 months after insertion. SOM recurred in 32.6% of the cases once, in 5.0% of the cases twice, and in 1.9% three times, requiring re-insertion of grommets. Recurrence appeared between 4 and 65 months after the first insertion. In three cases perforations of the tympanic membrane persisted and required tympanoplasty. Tympanometric examination and pure tone audiometry are necessary, in addition to pure tone audiometry to follow up successfully ventilated middle ears and to show recurrence as early as possible. Pre-existing but unsuspected sensorineural hearing loss was discovered in 10 cases. The deprivation of neural auditory pathways in early childhood and the possible retardation of speech development caused by SOM are mentioned. Normal hearing is the most important goal of therapy in children suffering from SOM, and insertion of ventilation tubes is the preferred method of achieving that goal safely. Adenoidectomy and treatment of upper airway infections are indispensable parts of the therapy of SOM. Regular follow up after insertion of grommets and even after their expulsion is necessary because of the high rate of late recurrence of SOM. Induction of cholesteatoma by grommets was not observed.

  10. Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization.

    PubMed

    Lezaja, Maja; Veljovic, Djordje; Manojlovic, Dragica; Milosevic, Milos; Mitrovic, Nenad; Janackovic, Djordje; Miletic, Vesna

    2015-02-01

    To determine the shear bond strength (SBS) between synthetic controlled porous hydroxyapatite (HAP) inserts and restorative materials and dimensional changes of insert-containing restorations during curing. Cylinder-shaped HAP inserts (4mm in diameter, 1.6mm thick) were cemented in dentin discs (5mm×1.6mm), cut mid-coronally from human third molars, using one of the following materials: universal microhybrid composite Filtek Z250, flowable composite Filtek Ultimate or glass-ionomer Vitrebond (all 3M ESPE). SBS of the same materials to HAP inserts was tested in a universal testing machine. Three-dimensional digital image correlation system Aramis (GOM) was used to measure strains and displacements. Data were statistically analyzed using one-way ANOVA with Tukey's post-test (α=0.05). SBS of restorative materials to HAP inserts ranged between 12.2±2.1MPa (Filtek Z250) and 0.7±0.4MPa (Filtek Z250 without an adhesive). The 'total-etch' approach of adhesive application significantly increased SBS of both Filtek Z250 (12.2±2.1MPa) and Filtek Ultimate flowable (9.5±2.5MPa) compared to the 'self-etch' approach (8.2±1.6MPa and 4.4±0.9MPa, respectively) (p<0.05). HAP inserts reduced polymerization shrinkage to below 0.5% as well as displacements in the central region of the restorations. Peripheral shrinkage of restorative materials was similar with and without HAP inserts as were displacements of Filtek Z250 and Vitrebond. Replacing major part of dentin clinically, especially in large cavities, HAP inserts may shorten clinical working time, improve dimensional stability of the restoration by reducing central shrinkage and displacements and provide adhesive bonding to universal composites following a 'total-etch' approach. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  11. Effect of vaginal administration of misoprostol before intrauterine contraceptive insertion following previous insertion failure: a double blind RCT.

    PubMed

    Bahamondes, M Valeria; Espejo-Arce, Ximena; Bahamondes, Luis

    2015-08-01

    Is pretreatment with misoprostol useful in insertion of intrauterine contraceptives (IUCs) after insertion failure at the first attempt? Pretreatment with intravaginal administration of 200 mcg of misoprostol after IUC insertion failure 10 and 4 h before the second attempt of IUC placement was significantly better than placebo at facilitating the insertion of an IUC. One of the reasons for low use of IUCs is the concept that insertion is difficult. Misoprostol was used in several randomized clinical trials (RCT) before IUC insertion to facilitate the insertion. In general, the results showed no significant differences when compared with placebo. However, most previous studies have been carried out among unselected women whereas the present study is among women with previous insertion failure. This was a double blind RCT conducted between February 2013 and October 2014. Participants were 104 women who requested an insertion of an IUC and the insertion failed at the first attempt. After insertion failure, the women received a sealed envelope with misoprostol or placebo. The randomization system (1: 1) in one block size was computer-generated. The study was conducted at a tertiary care centre. The women were instructed to insert vaginally one tablet of misoprostol 200 µg (Prostokos, Hebron, Cariacica, PE, Brazil) or placebo 10 and 4 h before the woman returned to the clinic for a new insertion attempt. The outcomes were successful IUC insertion and the use of a cervical dilator immediately prior to the insertion procedure. A total of 2639 women requested the insertion of an IUC during the study period. The IUC was inserted at the first attempt in 2535 women (96%) and 104 women in whom we were unable to insert the device were eligible to participate in the RCT. Four women declined and 100 women were randomized (55 for the misoprostol group and 45 for the placebo group). From the 100 participating women, the levonorgestrel-releasing intrauterine system (LNG-IUS) was

  12. Methanol Formation via Oxygen Insertion Chemistry in Ices

    NASA Astrophysics Data System (ADS)

    Bergner, Jennifer B.; Öberg, Karin I.; Rajappan, Mahesh

    2017-08-01

    We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O2 within a mixture of O2:CH4 and observe efficient production of CH3OH via O(1D) insertion. CH3OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH4: ∼65% of insertions lead to CH3OH, with the remainder leading instead to H2CO formation. There is no evidence for CH3 or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH3OH formation from O2 and CH4 diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

  13. Development of a needle insertion manipulator for central venous catheterization.

    PubMed

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Okada, Kaoru; Fujie, Masakatsu G; Hashizume, Makoto

    2012-03-01

    Central venous catheterization is a procedure in which a doctor inserts a catheter into a patient's vein for transfusions. Risks of this procedure include bleeding from the puncture of blood vessels and pneumothorax caused by pleural puncture. To avoid these and other risks, physicians are required to ensure that the needle is inserted securely and that it stops within the vein. We propose a robotic system for assisting venous puncture that is capable of alleviating the difficulties encountered during the conventional procedure, as well as minimizing the risks of complications. This paper describes the design and results of experiments conducted using a needle insertion manipulator. First, we investigated the relation between insertion force and angle into the vein to determine the appropriate insertion angle in relation to the blood vessel under physical conditions. The results indicated that the reaction force can be used to gauge whether the needle has been inserted into the vein in cases where the insertion angle is in the range 10-20°. Based on this result, we determined the mechanisms of the puncture device, which comprises a small, compact configuration. Experiments for accuracy validation were performed on a phantom. We evaluated the positioning accuracy using ultrasound images, and the results indicated an accuracy of 1.0 mm or better, which is considered feasible for venous puncture. In the phantom experiments, we confirmed that our manipulator was capable of placing the needle within the vein. The feasibility of this system was demonstrated in our experiments. Further studies, such as in vivo experiments, are required. Copyright © 2011 John Wiley & Sons, Ltd.

  14. Comparison of large-insert, small-insert and pyrosequencing libraries for metagenomic analysis.

    PubMed

    Danhorn, Thomas; Young, Curtis R; DeLong, Edward F

    2012-11-01

    The development of DNA sequencing methods for characterizing microbial communities has evolved rapidly over the past decades. To evaluate more traditional, as well as newer methodologies for DNA library preparation and sequencing, we compared fosmid, short-insert shotgun and 454 pyrosequencing libraries prepared from the same metagenomic DNA samples. GC content was elevated in all fosmid libraries, compared with shotgun and 454 libraries. Taxonomic composition of the different libraries suggested that this was caused by a relative underrepresentation of dominant taxonomic groups with low GC content, notably Prochlorales and the SAR11 cluster, in fosmid libraries. While these abundant taxa had a large impact on library representation, we also observed a positive correlation between taxon GC content and fosmid library representation in other low-GC taxa, suggesting a general trend. Analysis of gene category representation in different libraries indicated that the functional composition of a library was largely a reflection of its taxonomic composition, and no additional systematic biases against particular functional categories were detected at the level of sequencing depth in our samples. Another important but less predictable factor influencing the apparent taxonomic and functional library composition was the read length afforded by the different sequencing technologies. Our comparisons and analyses provide a detailed perspective on the influence of library type on the recovery of microbial taxa in metagenomic libraries and underscore the different uses and utilities of more traditional, as well as contemporary 'next-generation' DNA library construction and sequencing technologies for exploring the genomics of the natural microbial world.

  15. Patterns of Transposable Element Expression and Insertion in Cancer

    PubMed Central

    Clayton, Evan A.; Wang, Lu; Rishishwar, Lavanya; Wang, Jianrong; McDonald, John F.; Jordan, I. King

    2016-01-01

    Human transposable element (TE) activity in somatic tissues causes mutations that can contribute to tumorigenesis. Indeed, TE insertion mutations have been implicated in the etiology of a number of different cancer types. Nevertheless, the full extent of somatic TE activity, along with its relationship to tumorigenesis, have yet to be fully explored. Recent developments in bioinformatics software make it possible to analyze TE expression levels and TE insertional activity directly from transcriptome (RNA-seq) and whole genome (DNA-seq) next-generation sequence data. We applied these new sequence analysis techniques to matched normal and primary tumor patient samples from the Cancer Genome Atlas (TCGA) in order to analyze the patterns of TE expression and insertion for three cancer types: breast invasive carcinoma, head and neck squamous cell carcinoma, and lung adenocarcinoma. Our analysis focused on the three most abundant families of active human TEs: Alu, SVA, and L1. We found evidence for high levels of somatic TE activity for these three families in normal and cancer samples across diverse tissue types. Abundant transcripts for all three TE families were detected in both normal and cancer tissues along with an average of ~80 unique TE insertions per individual patient/tissue. We observed an increase in L1 transcript expression and L1 insertional activity in primary tumor samples for all three cancer types. Tumor-specific TE insertions are enriched for private mutations, consistent with a potentially causal role in tumorigenesis. We used genome feature analysis to investigate two specific cases of putative cancer-causing TE mutations in further detail. An Alu insertion in an upstream enhancer of the CBL tumor suppressor gene is associated with down-regulation of the gene in a single breast cancer patient, and an L1 insertion in the first exon of the BAALC gene also disrupts its expression in head and neck squamous cell carcinoma. Our results are consistent with

  16. Focus on peripherally inserted central catheters in critically ill patients

    PubMed Central

    Cotogni, Paolo; Pittiruti, Mauro

    2014-01-01

    Venous access devices are of pivotal importance for an increasing number of critically ill patients in a variety of disease states and in a variety of clinical settings (emergency, intensive care, surgery) and for different purposes (fluids or drugs infusions, parenteral nutrition, antibiotic therapy, hemodynamic monitoring, procedures of dialysis/apheresis). However, healthcare professionals are commonly worried about the possible consequences that may result using a central venous access device (CVAD) (mainly, bloodstream infections and thrombosis), both peripherally inserted central catheters (PICCs) and centrally inserted central catheters (CICCs). This review aims to discuss indications, insertion techniques, and care of PICCs in critically ill patients. PICCs have many advantages over standard CICCs. First of all, their insertion is easy and safe -due to their placement into peripheral veins of the arm- and the advantage of a central location of catheter tip suitable for all osmolarity and pH solutions. Using the ultrasound-guidance for the PICC insertion, the risk of hemothorax and pneumothorax can be avoided, as well as the possibility of primary malposition is very low. PICC placement is also appropriate to avoid post-procedural hemorrhage in patients with an abnormal coagulative state who need a CVAD. Some limits previously ascribed to PICCs (i.e., low flow rates, difficult central venous pressure monitoring, lack of safety for radio-diagnostic procedures, single-lumen) have delayed their start up in the intensive care units as common practice. Though, the recent development of power-injectable PICCs overcomes these technical limitations and PICCs have started to spread in critical care settings. Two important take-home messages may be drawn from this review. First, the incidence of complications varies depending on venous accesses and healthcare professionals should be aware of the different clinical performance as well as of the different risks

  17. A kinetic model for estimating the boron activation energies in the FeB and Fe2B layers during the gas-boriding of Armco iron: Effect of boride incubation times

    NASA Astrophysics Data System (ADS)

    Keddam, M.; Kulka, M.; Makuch, N.; Pertek, A.; Małdziński, L.

    2014-04-01

    The present work deals with a simulation of the growth kinetics of boride layers grown on Armco iron substrate. The formed boride layers (FeB + Fe2B) are obtained by the gas-boriding in the temperature range of 1073-1273 K during a time duration ranging from 80 to 240 min. The used approach solves the mass balance equations at the two growing fronts: (FeB/Fe2B) and (Fe2B/Fe) under certain assumptions. To consider the effect of the incubation times for the borides formation, the temperature-dependent function Φ(T) was incorporated in the model. The following input data: (the boriding temperature, the treatment time, the upper and lower values of boron concentrations in FeB and Fe2B and the experimental parabolic growth constants) are needed to determine the boron activation energies in the FeB and Fe2B layers. The obtained values of boron activation energies were then compared with the values available in the literature. Finally, a good agreement was obtained between the simulated values of boride layers thicknesses and the experimental ones in the temperature range of 1073-1273 K.

  18. Long acting betaxolol ocular inserts based on polymer composite.

    PubMed

    Gevariya, Hitesh B; Patel, Jayvadan K

    2013-08-01

    Poor bioavailability and therapeutic response of conventional therapy due to many pre-corneal constraints necessitate the development of novel controlled and sustained ocular drug delivery to become a standard one in modern pharmaceutical era. This investigation aimed to study the drug release kinetics of betaxolol hydrochloride from a hydrophobic matrix system of PMMA cast with incorporating different proportions of polyethylene oxide (PEO) and evaluate its ability to improve ocular bioavailability and duration of action for the drug. Matrix type ocular inserts were prepared by the film casting technique and characterized in vitro by drug release studies using a flow through apparatus that simulated the eye conditions. All the formulations were subjected to physicochemical evaluation. Rabbit model with steroid induced glaucoma was used to establish in vivo efficacy of inserts. Polymer composition and concentration significantly affected the drug release based on change in diffusional path length and formation of gelaneous pores by polymer erosion. Formulations released the drug by non-fickian diffusion including anomalous transport (0.51). It was also observed that increasing the proportion of PEO in to PMMA does not affect the blend miscibility. IVIVC suggested no significant difference (P< 0.001) between in vitro and in vivo release of drug from inserts. In vivo IOP lowering activity was better for optimized insert F8 (for 24 h) as compared to eye drops (10 h). This ocular insert could be a promising once-a-day sustained release formulation for treating glaucoma.

  19. Some physical and chemical indices of clique-inserted lattices

    NASA Astrophysics Data System (ADS)

    Zhang, Zuhe

    2013-10-01

    The operation of replacing every vertex of an r-regular lattice H by a complete graph of order r is called clique-insertion, and the resulting lattice is called the clique-inserted lattice of H. For any given r-regular lattice, applying this operation iteratively, an infinite family of r-regular lattices is generated. Some interesting lattices including the 3-12-12 lattice can be constructed this way. In this paper, we recall the relationship between the spectra of an r-regular lattice and that of its clique-inserted lattice, and investigate the graph energy and resistance distance statistics. As an application, the asymptotic energy per vertex and average resistance distance of the 3-12-12 and 3-6-24 lattices are computed. We also give formulae expressing the numbers of spanning trees and dimer coverings of the kth iterated clique-inserted lattices in terms of those of the original one. Moreover, we show that new families of expander graphs can be constructed from the known ones by clique-insertion.

  20. Recombination of an intrachromosomal paracentric insertion of chromosome 3

    SciTech Connect

    Best, R.G.; Burnett, W.J.; Brock, J.K.

    1994-09-01

    Cytogenetic studies were initiated on a newborn female due to multiple congenital anomalies including microcephaly, clinodactyly, abnormal positioning of hands, left facial palsy, heart defect, sacral dimple, and facial dysmorphic features. Facial features were described as low set rotated ears, nystagmus, and a small, flattened nose. A structural rearrangement of the long arm of chromosome 3 was observed with a complex banding pattern. Study of parental chromosomes revealed a normal male pattern for the father, and an intrachromosomal insertion on the long arm of chromosome 3 for the mother described as 46,XX,dir ins(3)(q21q23q26.2). Further characterization of the proband`s structurally abnormal chromosome 3 revealed a karyotype best described as: 46,XX,rec(3),dupq23{r_arrow}q26.2::q21{r_arrow}q23,dir ins(3)(q21q23q26.2), which is a partial duplication of both the inserted segment as well as the intervening segment between the inserted segment and the insertion site. This would appear to be the result of a three-strand double cross-over within the insertion loop. Molecular cytogenetic studies are presently underway to further elucidate chromosome structure of the proband and her mother.

  1. Transposable element insertions have strongly affected human evolution.

    PubMed

    Britten, Roy J

    2010-11-16

    Comparison of a full collection of the transposable element (TE) sequences of vertebrates with genome sequences shows that the human genome makes 655 perfect full-length matches. The cause is that the human genome contains many active TEs that have caused TE inserts in relatively recent times. These TE inserts in the human genome are several types of young Alus (AluYa5, AluYb8, AluYc1, etc.). Work in many laboratories has shown that such inserts have many effects including changes in gene expression, increases in recombination, and unequal crossover. The time of these very effective changes in the human lineage genome extends back about 4 million years according to these data and very likely much earlier. Rapid human lineage-specific evolution, including brain size is known to have also occurred in the last few million years. Alu insertions likely underlie rapid human lineage evolution. They are known to have many effects. Examples are listed in which TE sequences have influenced human-specific genes. The proposed model is that the many TE insertions created many potentially effective changes and those selected were responsible for a part of the striking human lineage evolution. The combination of the results of these events that were selected during human lineage evolution was apparently effective in producing a successful and rapidly evolving species.

  2. Insertion forces with intrauterine devices: implications for uterine perforation.

    PubMed

    Goldstuck, N D

    1987-08-01

    The force required to insert a Copper 7, Multiload Copper or Nova T IUD was measured in 197 successful and 25 unsuccessful insertion attempts. These forces were compared with the forces required to perforate freshly obtained uterine specimens with a metal uterine sound and Dalkon shield device, as well as with the clinically tested devices. The mean insertion forces for the Copper 7, Nova T and Multiload Copper devices were 1.502 N, 2.134 N and 4.041 N respectively, while the mean insertion pressures (N/mm2) were 0.203, 0.209 and 0.122 respectively. The mean in vitro fundal perforation forces with metal sounds was 20.7 N and with the Dalkon shield 31.6 N. The Copper 7, Multiload Copper and Nova T IUDs achieved mean in vitro forces of 5.75 N, 9.2 and 8.1 N respectively, without causing perforation. Primary uterine perforation at the time of insertion of these devices appears unlikely.

  3. EGFR exon 20 insertion mutation in Japanese lung cancer.

    PubMed

    Sasaki, Hidefumi; Endo, Katsuhiko; Takada, Minoru; Kawahara, Masaaki; Kitahara, Naoto; Tanaka, Hisaichi; Okumura, Meinoshin; Matsumura, Akihide; Iuchi, Keiji; Kawaguchi, Tomoya; Kawano, Osamu; Yukiue, Haruhiro; Yokoyama, Tomoki; Yano, Motoki; Fujii, Yoshitaka

    2007-12-01

    Mutations of the epidermal growth factor receptor (EGFR) gene have been reported in non-small cell lung cancer (NSCLC), especially in female, never smoker patients with adenocarcinoma. Some common somatic mutations in EGFR, including deletion mutations in exon 19 and leucine to arginine substitution at amino acid position 858 (L858R) in exon 21, have been examined for their ability to predict sensitivity to gefitinib or erlotinib. On the other hand, previous report has shown that the insertion mutation at exon 20 is related to gefitinib resistance. We investigated the exon 20 EGFR mutation statuses in 322 surgically treated non-small cell lung cancer cases. Two hundred and five adenocarcinoma cases were included. The presence or absence of EGFR mutations of kinase domains was analyzed by direct sequences. EGFR insertion mutations at exon 20 were found from 7 of 322 (2.17%) lung cancer patients. We also detected the 18 deletion type mutations in exon 19, and 25 L858R type mutations in exon 21. There was a tendency towards higher exon 20 insertion ratio in never smoker (never smoker 4.4% versus smoker 1.3%, p=0.0996) and female (female 4.5% versus male 1.3%, p=0.0917). Two exon 20 insertion cases were treated with gefitinib and failed to response. EGFR insertion mutation in exon 20 could not be ignored from Japanese lung cancers.

  4. LMA Supreme insertion by novices in manikins and patients.

    PubMed

    Howes, B W; Wharton, N M; Gibbison, B; Cook, T M

    2010-04-01

    The LMA Supreme has been suggested for use in emergency situations by medical personnel with no experience in endotracheal intubation. We evaluated the LMA Supreme when inserted by non-anaesthetists, firstly in a manikin and then in patients. Fifty airway novices inserted a LMA Supreme in a manikin without any complications so we proceeded to the patient phase. Fifty airway novices inserted the LMA Supreme in anaesthetised patients undergoing elective surgery. First time insertion success rate was 86% and overall insertion success rate was 100%. Mechanical ventilation was successful in all cases. Median (IQR [range]) time to establish an airway was 34 s (26-40 [18-145] s). Median (IQR [range]) pharyngeal seal pressure was 23 cmH(2)O (19-28 [13-40] cmH(2)O). There were no important complications. Results are consistent with previous studies of use of the LMA Supreme by airway experts. We conclude that the LMA supreme is suitable for use by airway novices. Further research is needed before it may be recommended for cardiopulmonary resuscitation and emergency airway use.

  5. Staphylococcus aureus infections following knee and hip prosthesis insertion procedures.

    PubMed

    Arduino, Jean Marie; Kaye, Keith S; Reed, Shelby D; Peter, Senaka A; Sexton, Daniel J; Chen, Luke F; Hardy, N Chantelle; Tong, Steven Yc; Smugar, Steven S; Fowler, Vance G; Anderson, Deverick J

    2015-01-01

    Staphylococcus aureus is the most common and most important pathogen following knee and hip arthroplasty procedures. Understanding the epidemiology of invasive S. aureus infections is important to quantify this serious complication. This nested retrospective cohort analysis included adult patients who had undergone insertion of knee or hip prostheses with clean or clean-contaminated wound class at 11 hospitals between 2003-2006. Invasive S. aureus infections, non-superficial incisional surgical site infections (SSIs) and blood stream infections (BSIs), were prospectively identified following each procedure. Prevalence rates, per 100 procedures, were estimated. 13,719 prosthetic knee (62%) and hip (38%) insertion procedures were performed. Of 92 invasive S. aureus infections identified, SSIs were more common (80%) than SSI and BSI (10%) or BSI alone (10%). The rate of invasive S. aureus infection/100 procedures was 0.57 [95% CI: 0.43-0.73] for knee insertion and 0.83 [95% CI: 0.61-1.08] for hip insertion. More than half (53%) were methicillin-resistant. Median time-to-onset of infection was 34 and 26 days for knee and hip insertion, respectively. Infection was associated with higher National Healthcare Safety Network risk index (p ≤ 0.0001). Post-operative invasive S. aureus infections were rare, but difficult-to-treat methicillin-resistant infections were relatively common. Optimizing preventative efforts may greatly reduce the healthcare burden associated with S. aureus infections.

  6. Quantitative assessment of insertion sequence impact on bacterial genome architecture

    PubMed Central

    Bishop, Brian; Wright, Meredith S.

    2016-01-01

    Insertion sequence (IS) elements are important mediators of genome plasticity and can lead to phenotypic changes with evolutionary significance. In multidrug-resistant Acinetobacter baumannii and Klebsiella pneumoniae, IS elements have contributed significantly to the mobilization of genes that encode resistance to antimicrobial drugs. A systematic analysis of IS elements is needed for a more comprehensive understanding of their evolutionary impact. We developed a computational approach (ISseeker) to annotate IS elements in draft genome assemblies and applied the method to analysis of IS elements in all publicly available A. baumannii(>1000) and K. pneumoniae(>800) genome sequences, in a phylogenetic context. Most IS elements in A. baumanniigenomes are species-specific ISAba elements, whereas K. pneumoniaegenomes contain significant numbers of both ISKpn elements and elements that are found throughout the Enterobacteriaceae. A. baumanniigenomes have a higher density of IS elements than K. pneumoniae, averaging ~33 vs ~27 copies per genome. In K. pneumoniae, several insertion sites are shared by most genomes in the ST258 clade, whereas in A. baumannii, different IS elements are abundant in different phylogenetic groups, even among closely related Global Clone 2 strains. IS elements differ in the distribution of insertion locations relative to genes, with some more likely to disrupt genes and others predominantly in intergenic regions. Several genes and intergenic regions had multiple independent insertion events, suggesting that those events may confer a selective advantage. Genome- and taxon-wide characterization of insertion locations revealed that IS elements have been active contributors to genome diversity in both species.

  7. Seamless lesion insertion in digital mammography: methodology and reader study

    NASA Astrophysics Data System (ADS)

    Pezeshk, Aria; Petrick, Nicholas; Sahiner, Berkman

    2016-03-01

    Collection of large repositories of clinical images containing verified cancer locations is costly and time consuming due to difficulties associated with both the accumulation of data and establishment of the ground truth. This problem poses a significant challenge to the development of machine learning algorithms that require large amounts of data to properly train and avoid overfitting. In this paper we expand the methods in our previous publications by making several modifications that significantly increase the speed of our insertion algorithms, thereby allowing them to be used for inserting lesions that are much larger in size. These algorithms have been incorporated into an image composition tool that we have made publicly available. This tool allows users to modify or supplement existing datasets by seamlessly inserting a real breast mass or micro-calcification cluster extracted from a source digital mammogram into a different location on another mammogram. We demonstrate examples of the performance of this tool on clinical cases taken from the University of South Florida Digital Database for Screening Mammography (DDSM). Finally, we report the results of a reader study evaluating the realism of inserted lesions compared to clinical lesions. Analysis of the radiologist scores in the study using receiver operating characteristic (ROC) methodology indicates that inserted lesions cannot be reliably distinguished from clinical lesions.

  8. Direct insertion of metal ions into tetrasulfonated phthalocyanine

    SciTech Connect

    Linkous, C.A.; Shea, C.E.; Jaber, M.R.A. )

    1989-07-01

    A series of metal salts were reacted with aqueous solutions of the tetrasulfonated free base phthalocyanine (H{sub 2}TsPc) in an attempt to prepare the corresponding metal TsPc derivative by direct insertion instead of the usual template reaction in a urea melt. Spectrophotometric analysis showed that Ni{sup 2+}, Cu{sup 2+}, Zn{sup 2+}, Co{sup 2+}, Fe{sup 2+}, Mn{sup 2+}, Pd{sup 2+}, Cd{sup 2+}, and Sn{sup 2+} could be successfully inserted; higher oxidation states as well as Pb{sup 2+} caused precipitation. Reducing species such as Cr{sup 2+} and V{sup 2+} reduced H{sub 2}TsPc but did not insert; Sn{sup 2+} inserted with formation of an air-sensitive intermediate species. Mg{sup 2+}, VO{sup 2+}, Pt{sup 2+}, and Hg{sup 2+} were unreactive. It is recommended that insertion may be the preferable method for synthesis of the MTsPc's listed above when air sensitivity, reaction time, and microscale are important issues in an overall synthetic scheme. 24 refs., 4 figs.

  9. Comparison of large-insert, small-insert and pyrosequencing libraries for metagenomic analysis

    PubMed Central

    Danhorn, Thomas; Young, Curtis R; DeLong, Edward F

    2012-01-01

    The development of DNA sequencing methods for characterizing microbial communities has evolved rapidly over the past decades. To evaluate more traditional, as well as newer methodologies for DNA library preparation and sequencing, we compared fosmid, short-insert shotgun and 454 pyrosequencing libraries prepared from the same metagenomic DNA samples. GC content was elevated in all fosmid libraries, compared with shotgun and 454 libraries. Taxonomic composition of the different libraries suggested that this was caused by a relative underrepresentation of dominant taxonomic groups with low GC content, notably Prochlorales and the SAR11 cluster, in fosmid libraries. While these abundant taxa had a large impact on library representation, we also observed a positive correlation between taxon GC content and fosmid library representation in other low-GC taxa, suggesting a general trend. Analysis of gene category representation in different libraries indicated that the functional composition of a library was largely a reflection of its taxonomic composition, and no additional systematic biases against particular functional categories were detected at the level of sequencing depth in our samples. Another important but less predictable factor influencing the apparent taxonomic and functional library composition was the read length afforded by the different sequencing technologies. Our comparisons and analyses provide a detailed perspective on the influence of library type on the recovery of microbial taxa in metagenomic libraries and underscore the different uses and utilities of more traditional, as well as contemporary ‘next-generation' DNA library construction and sequencing technologies for exploring the genomics of the natural microbial world. PMID:22534608

  10. Molecular and genetic characterization of an Alcaligenes eutrophus insertion element.

    PubMed Central

    Kung, S S; Chen, J; Chow, W Y

    1992-01-01

    An insertion element, ISAE1, was discovered during the molecular analysis of mutants defective in the autotrophic growth (Aut-) of Alcaligenes eutrophus H1-4, a mitomycin C-generated derivative of strain H1. ISAE1 is 1,313 bp long, has 12-bp nearly perfect inverted terminal repeats, and contains an open reading frame that has a coding capacity of 408 amino acids. Direct repeats of 8 bp were generated by insertion of ISAE1 into chromosomes or plasmids. Most insertion were found in the AT-rich target sites. The distribution of ISAE1 is limited to A. eutrophus H1 (ATCC 17698) and H16 (ATCC 17699). Variants with newly transposed copies of ISAE1 could be isolated at an elevated frequency by changing the growth conditions. Images PMID:1334068

  11. Synchronized monochromator and insertion device energy scans at SLS

    SciTech Connect

    Krempasky, J.; Flechsig, U.; Korhonen, T.; Zimoch, D.; Quitmann, Ch.; Nolting, F.

    2010-06-23

    Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a 'master' controlling the undulator 'slave' energy position. This master-slave software implementation exploits EPICS distributed device control over computer network and allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.

  12. Master-slave robotic system for needle indentation and insertion.

    PubMed

    Shin, Jaehyun; Zhong, Yongmin; Gu, Chengfan

    2017-09-22

    Bilateral control of a master-slave robotic system is a challenging issue in robotic-assisted minimally invasive surgery. It requires the knowledge on contact interaction between a surgical (slave) robot and soft tissues. This paper presents a master-slave robotic system for needle indentation and insertion. This master-slave robotic system is able to characterize the contact interaction between the robotic needle and soft tissues. A bilateral controller is implemented using a linear motor for robotic needle indentation and insertion. A new nonlinear state observer is developed to online monitor the contact interaction with soft tissues. Experimental results demonstrate the efficacy of the proposed master-slave robotic system for robotic needle indentation and needle insertion.

  13. A Nasogastric Tube Inserted into the Gastrocutaneous Fistula

    PubMed Central

    Kim, Yang Soo; Kim, Joon Sung; Yu, In Hee; Jeong, Ji Young; Jung, Sung Hee; Jo, Yil Ryun

    2011-01-01

    We reported a case in which a nasogastric tube was inserted into the gastrocutaneous fistula, diagnosed by abdominal computed tomography. A 78-year-old man with a history of recurrent cerebral hemorrhage had a percutaneous endoscopic gastrostomy tube due to dysphagia for 2 years. However, soft tissue infection at the gastrostomy site caused the removal of the tube. Immediately, antibiotic agents were infused. For appropriate hydration and medication, a nasogastric tube was inserted. However, there was no significant improvement of the soft tissue infection. Moreover, the amount of bloody exudate increased. Abdominal computed tomography revealed the nasogastric tube placed under the patient's skin via gastrocutaneous fistula. The nasogastric tube was removed, and an antibiotic agents were maintained. After 3 weeks, the signs of infection fully improved, and percutaneous endoscopic gastrostomy was performed again. This case shows necessities of an appropriate interval between removal of the gastrostomy tube and insertion of a nasogastric tube, and suspicion of existence of gastrocutaneous fistula. PMID:22506228

  14. Genetic aspects of targeted insertion mutagenesis in yeasts.

    PubMed

    Klinner, U; Schäfer, B

    2004-05-01

    Targeted insertion mutagenesis is a main molecular tool of yeast science initially applied in Saccharomyces cerevisiae. The method was extended to fission yeast Schizosaccharomyces pombe and to "non-conventional" yeast species, which show specific properties of special interest to both basic and applied research. Consequently, the behaviour of such non-Saccharomyces yeasts is reviewed against the background of the knowledge of targeted insertion mutagenesis in S. cerevisiae. Data of homologous integration efficiencies obtained with circular, ends-in or ends-out vectors in several yeasts are compared. We follow details of targeted insertion mutagenesis in order to recognize possible rate-limiting steps. The route of the vector to the target and possible mechanisms of its integration into chromosomal genes are considered. Specific features of some yeast species are discussed. In addition, similar approaches based on homologous recombination that have been established for the mitochondrial genome of S. cerevisiae are described.

  15. Insertion of liquid crystal molecules into hydrocarbon monolayers

    SciTech Connect

    Popov, Piotr Mann, Elizabeth K.; Lacks, Daniel J.; Jákli, Antal

    2014-08-07

    Atomistic molecular dynamics simulations were carried out to investigate the molecular mechanisms of vertical surface alignment of liquid crystals. We study the insertion of nCB (4-Cyano-4{sup ′}-n-biphenyl) molecules with n = 0,…,6 into a bent-core liquid crystal monolayer that was recently found to provide good vertical alignment for liquid crystals. The results suggest a complex-free energy landscape for the liquid crystal within the layer. The preferred insertion direction of the nCB molecules (core or tail first) varies with n, which can be explained by entropic considerations. The role of the dipole moments was found to be negligible. As vertical alignment is the leading form of present day liquid crystal displays (LCD), these results will help guide improvement of the LCD technology, as well as lend insight into the more general problem of insertion of biological and other molecules into lipid and surfactant layers.

  16. Polyglutamine expansion in huntingtin increases its insertion into lipid bilayers.

    PubMed

    Kegel, Kimberly B; Schewkunow, Vitali; Sapp, Ellen; Masso, Nicholas; Wanker, Erich E; DiFiglia, Marian; Goldmann, Wolfgang H

    2009-09-25

    An expanded polyglutamine (Q) tract (>37Q) in huntingtin (htt) causes Huntington disease. Htt associates with membranes and polyglutamine expansion in htt may alter membrane function in Huntington disease through a mechanism that is not known. Here we used differential scanning calorimetry to examine the effects of polyQ expansion in htt on its insertion into lipid bilayers. We prepared synthetic lipid vesicles composed of phosphatidylcholine and phosphatidylethanolamine and tested interactions of htt amino acids 1-89 with 20Q, 32Q or 53Q with the vesicles. GST-htt1-89 with 53Q inserted into synthetic lipid vesicles significantly more than GST-htt1-89 with 20Q or 32Q. We speculate that by inserting more into cell membranes, mutant huntingtin could increase disorder within the lipid bilayer and thereby disturb cellular membrane function.

  17. Synchronized monochromator and insertion device energy scans at SLS

    NASA Astrophysics Data System (ADS)

    Krempaský, J.; Flechsig, U.; Korhonen, T.; Zimoch, D.; Quitmann, Ch.; Nolting, F.

    2010-06-01

    Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a "master" controlling the undulator "slave" energy position. This master-slave software implementation exploits EPICS distributed device control over computer network and allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.

  18. Optimized production and concentration of lentiviral vectors containing large inserts.

    PubMed

    al Yacoub, Nadya; Romanowska, Malgorzata; Haritonova, Natalie; Foerster, John

    2007-07-01

    Generation of high titer lentiviral stocks and efficient virus concentration are central to maximize the utility of lentiviral technology. Here we evaluate published protocols for lentivirus production on a range of transfer vectors differing in size (7.5-13.2 kb). We present a modified virus production protocol robustly yielding useful titers (up to 10(7)/ml) for a range of different transfer vectors containing packaging inserts up to 7.5 kb. Moreover, we find that virus recovery after concentration by ultracentrifugation depends on the size of the packaged inserts, heavily decreasing for large packaged inserts. We describe a fast (4 h) centrifugation protocol at reduced speed allowing high virus recovery even for large and fragile lentivirus vectors. The protocols outlined in the current report should be useful for many labs interested in producing and concentrating high titer lentiviral stocks.

  19. Gene Insertion Into Genomic Safe Harbors for Human Gene Therapy

    PubMed Central

    Papapetrou, Eirini P; Schambach, Axel

    2016-01-01

    Genomic safe harbors (GSHs) are sites in the genome able to accommodate the integration of new genetic material in a manner that ensures that the newly inserted genetic elements: (i) function predictably and (ii) do not cause alterations of the host genome posing a risk to the host cell or organism. GSHs are thus ideal sites for transgene insertion whose use can empower functional genetics studies in basic research and therapeutic applications in human gene therapy. Currently, no fully validated GSHs exist in the human genome. Here, we review our formerly proposed GSH criteria and discuss additional considerations on extending these criteria, on strategies for the identification and validation of GSHs, as well as future prospects on GSH targeting for therapeutic applications. In view of recent advances in genome biology, gene targeting technologies, and regenerative medicine, gene insertion into GSHs can potentially catalyze nearly all applications in human gene therapy. PMID:26867951

  20. Tool Life Detecting System Using Damage Sensor-Integrated Insert

    NASA Astrophysics Data System (ADS)

    Sekiya, Katsuhiko; Yamane, Yasuo; Torimoto, Ayumu

    In-process tool life detecting system has been developed. In order to detect tool life, we monitored breakage of an electrical conductive thin film band of titanium nitride (TiN) on flank faces of a ceramic insert that was an insulation material. The conductive band was parallel to the cutting edge and was broken by fracture of the cutting edge or excessive tool wear. A coil and a capacitor were connected in series to the band on an insert to make a series resonance circuit in a tool holder for turning, or in an arbor for face milling. A detecting coil with high frequency oscillator was coupled to the coil in the holder/arbor electromagnetically. An electromagnetic induction between two coils was used to take the signal from the insert. The system developed in this study showed good stability against electric noises radiated from electrical devices of machine tools.

  1. Genome ARTIST: a robust, high-accuracy aligner tool for mapping transposon insertions and self-insertions.

    PubMed

    Ecovoiu, Alexandru Al; Ghionoiu, Iulian Constantin; Ciuca, Andrei Mihai; Ratiu, Attila Cristian

    2016-01-01

    A critical topic of insertional mutagenesis experiments performed on model organisms is mapping the hits of artificial transposons (ATs) at nucleotide level accuracy. Mapping errors may occur when sequencing artifacts or mutations as single nucleotide polymorphisms (SNPs) and small indels are present very close to the junction between a genomic sequence and a transposon inverted repeat (TIR). Another particular item of insertional mutagenesis is mapping of the transposon self-insertions and, to our best knowledge, there is no publicly available mapping tool designed to analyze such molecular events. We developed Genome ARTIST, a pairwise gapped aligner tool which works out both issues by means of an original, robust mapping strategy. Genome ARTIST is not designed to use next-generation sequencing (NGS) data but to analyze ATs insertions obtained in small to medium-scale mutagenesis experiments. Genome ARTIST employs a heuristic approach to find DNA sequence similarities and harnesses a multi-step implementation of a Smith-Waterman adapted algorithm to compute the mapping alignments. The experience is enhanced by easily customizable parameters and a user-friendly interface that describes the genomic landscape surrounding the insertion. Genome ARTIST is functional with many genomes of bacteria and eukaryotes available in Ensembl and GenBank repositories. Our tool specifically harnesses the sequence annotation data provided by FlyBase for Drosophila melanogaster (the fruit fly), which enables mapping of insertions relative to various genomic features such as natural transposons. Genome ARTIST was tested against other alignment tools using relevant query sequences derived from the D. melanogaster and Mus musculus (mouse) genomes. Real and simulated query sequences were also comparatively inquired, revealing that Genome ARTIST is a very robust solution for mapping transposon insertions. Genome ARTIST is a stand-alone user-friendly application, designed for high

  2. Spot welding of steel and aluminum using insert sheet

    SciTech Connect

    Oikawa, H.; Saito, T.; Yoshimura, T.

    1994-12-31

    Automobile industries have been increasingly interested in the use of aluminum and thus joining of steel and aluminum becomes of importance. The joining of the two types of metal raises a problem of brittle welds caused by the formation of intermetallic compounds. The authors solved the problem by using an insert sheet. This paper deals with the resistance spot welding of steel and aluminum sheets using insert sheets. The insert sheet used in the present development was a steel/aluminum clad sheet of the 0.8 mm thickness with 50% steel and 50% aluminum. The clad sheet was produced by warm rolling of steel and aluminum with a direct resistance heating process. Steel to be warm rolled was of EDDQ of the 0.4 mm thickness and aluminum was of JIS A1050 of 0.6 mm thickness. The mechanical properties of the insert clad sheets were in between those of the steel sheets and the aluminum sheets, while the clad sheets showed much better formability than the aluminum sheets. Resistance spot welding was conducted for 0.8 mm thick EDDQ steel sheets and 1.0 mm thick aluminum alloy (AL-5.5%Mg) sheets under the welding force of 1.96 kN, welding current ranging between 4.2 and 20.1 kA, and welding time from 0.5 to 10 cycles. The steel was spot welded to the steel side of the insert sheet while the aluminum was welded to the aluminum side. What the authors investigated were the applicable welding current range, nugget diameter, tensile shear strength, U-tension strength, and macro- and microstructures. In conclusion, steel sheets can be spot welded to aluminum sheets without difficulty by using clad sheets as insert materials while the strength level of the dissimilar metal spot welds is close to that of aluminum joints.

  3. Rhizobium phaseoli symbiotic mutants with transposon Tn5 insertions.

    PubMed Central

    Noel, K D; Sanchez, A; Fernandez, L; Leemans, J; Cevallos, M A

    1984-01-01

    Rhizobium phaseoli CFN42 DNA was mutated by random insertion of Tn5 from suicide plasmid pJB4JI to obtain independently arising strains that were defective in symbiosis with Phaseolus vulgaris but grew normally outside the plant. When these mutants were incubated with the plant, one did not initiate visible nodule tissue (Nod-), seven led to slow nodule development (Ndv), and two led to superficially normal early nodule development but lacked symbiotic nitrogenase activity (Sna-). The Nod- mutant lacked the large transmissible indigenous plasmid pCFN42d that has homology to Klebsiella pneumoniae nitrogenase (nif) genes. The other mutants had normal plasmid content. In the two Sna- mutants and one Ndv mutant, Tn5 had inserted into plasmid pCFN42d outside the region of nif homology. The insertions of the other Ndv mutants were apparently in the chromosome. They were not in plasmids detected on agarose gels, and, in contrast to insertions on indigenous plasmids, they were transmitted in crosses to wild-type strain CFN42 at the same frequency as auxotrophic markers and with the same enhancement of transmission by conjugation plasmid R68.45. In these Ndv mutants the Tn5 insertions were the same as or very closely linked to mutations causing the Ndv phenotype. However, in two mutants with Tn5 insertions on plasmid pCFN42d, an additional mutation on the same plasmid, rather than Tn5, was responsible for the Sna- or Ndv phenotype. When plasmid pJB4JI was transferred to two other R. phaseoli strains, analysis of symbiotic mutants was complicated by Tn5-containing deleted forms of pJB4JI that were stably maintained. Images PMID:6325385

  4. Molecular archeology of L1 insertions in the human genome

    PubMed Central

    Szak, Suzanne T; Pickeral, Oxana K; Makalowski, Wojciech; Boguski, Mark S; Landsman, David; Boeke, Jef D

    2002-01-01

    Background As the rough draft of the human genome sequence nears a finished product and other genome-sequencing projects accumulate sequence data exponentially, bioinformatics is emerging as an important tool for studies of transposon biology. In particular, L1 elements exhibit a variety of sequence structures after insertion into the human genome that are amenable to computational analysis. We carried out a detailed analysis of the anatomy and distribution of L1 elements in the human genome using a new computer program, TSDfinder, designed to identify transposon boundaries precisely. Results Structural variants of L1 elements shared similar trends in the length and quality of their target site duplications (TSDs) and poly(A) tails. Furthermore, we found no correlation between the composition and genomic location of the pre-insertion locus and the resulting anatomy of the L1 insertion. We verified that L1 insertions with TSDs have the 5'-TTAAAA-3' cleavage site associated with L1 endonuclease activity. In addition, the second target DNA cut required for L1 insertion weakly matches the consensus pattern TTAAAA. On the other hand, the L1-internal breakpoints of deleted and inverted L1 elements do not resemble L1 endonuclease cleavage sites. Finally, the genome sequence data indicate that whereas singly inverted elements are common, doubly inverted elements are almost never found. Conclusions The sequence data give no indication that the creation of L1 structural variants depends on characteristics of the insertion locus. In addition, the formation of 5' truncated and 5' inverted L1s are probably not due to the action of the L1 endonuclease. PMID:12372140

  5. Distraction Using the BUZZY for Children During an IV Insertion.

    PubMed

    Moadad, Nemat; Kozman, Katia; Shahine, Randa; Ohanian, Shake; Badr, Lina Kurdahi

    2016-01-01

    Needle pricks are rated by children as their most feared medical event resulting in acute pain, anxiety and distress, which negatively affects both the child and his/her parents. To investigate the effects of external cold and vibration via the "BUZZY" on pain ratings of children, their parents and nurses during peripheral IV insertion, to measure the time to a successful IV insertion and to assess the factors that are associated with pain perception of children. In this randomized control trial (RCT), children between the ages of 4 to 12years were assigned to either an intervention or a control group. The intervention group (n=25) had the "BUZZY" applied during IV insertion while the control group (n=23) did not have the "BUZZY". Children were asked to rate their pain along with their parents and nurses on the Wong-Baker FACES Pain Rating Scale. Time to successful IV insertion and background characteristic of children were assessed and compared. Pain scores were significantly lower in the "BUZZY" group for children and the nurses. Time to a successful IV insertion did not differ between groups. Gender, age, previous hospitalization, diagnoses and analgesics were all factors associated with the children's pain scores. However, a multiple regression analysis found that only the "BUZZY" remained a significant predictor of pain scores in children. The "BUZZY" may be an easily accessed, inexpensive ($39.95 each at $0.09 per 3 minute stick), and effective technique to control or reduce pain in young children undergoing IV insertion. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Characterisation of protein stability in rod-insert vaginal rings.

    PubMed

    Pattani, Aditya; Lowry, Deborah; Curran, Rhonda M; McGrath, Stephanie; Kett, Vicky L; Andrews, Gavin P; Malcolm, R Karl

    2012-07-01

    A major goal in vaccine development is elimination of the 'cold chain', the transport and storage system for maintenance and distribution of the vaccine product. This is particularly pertinent to liquid formulation of vaccines. We have previously described the rod-insert vaginal ring (RiR) device, comprising an elastomeric body into which are inserted lyophilised, rod-shaped, solid drug dosage forms, and having potential for sustained mucosal delivery of biomacromolecules, such as HIV envelope protein-based vaccine candidates. Given the solid, lyophilised nature of these insert dosage forms, we hypothesised that antigen stability may be significantly increased compared with more conventional solubilised vaginal gel format. In this study, we prepared and tested vaginal ring devices fitted with lyophilised rod inserts containing the model antigen bovine serum albumin (BSA). Both the RiRs and the gels that were freeze-dried to prepare the inserts were evaluated for BSA stability using PAGE, turbidimetry, microbial load, MALDI-TOF and qualitative precipitate solubility measurements. When stored at 4 °C, but not when stored at 40 °C/75% RH, the RiR formulation offered protection against structural and conformational changes to BSA. The insert also retained matrix integrity and release characteristics. The results demonstrate that lypophilised gels can provide relative protection against degradation at lower temperatures compared to semi-solid gels. The major mechanism of degradation at 40 °C/75% RH was shown to be protein aggregation. Finally, in a preliminary study, we found that addition of trehalose to the formulation significantly reduces the rate of BSA degradation compared to the original formulation when stored at 40 °C/75% RH. Establishing the mechanism of degradation, and finding that degradation is decelerated in the presence of trehalose, will help inform further development of RiRs specifically and polymer based freeze-dried systems in general.

  7. Method of modifying a volume mesh using sheet insertion

    DOEpatents

    Borden, Michael J.; Shepherd, Jason F.

    2006-08-29

    A method and machine-readable medium provide a technique to modify a hexahedral finite element volume mesh using dual generation and sheet insertion. After generating a dual of a volume stack (mesh), a predetermined algorithm may be followed to modify (refine) the volume mesh of hexahedral elements. The predetermined algorithm may include the steps of locating a sheet of hexahedral mesh elements, determining a plurality of hexahedral elements within the sheet to refine, shrinking the plurality of elements, and inserting a new sheet of hexahedral elements adjacently to modify the volume mesh. Additionally, another predetermined algorithm using mesh cutting may be followed to modify a volume mesh.

  8. Neutron reflectometry of supported hybrid bilayers with inserted peptide

    PubMed Central

    Smith, Matthew B.; McGillivray, Duncan J.; Genzer, Jan; Lösche, Mathias; Kilpatrick, Peter K.

    2011-01-01

    The insertion of a synthetic amphiphilic, α-helical peptide into a supported hybrid bilayer membrane (HBM) was studied by neutron reflectometry to elucidate the resulting nanostructure. The HBM consisted of a self-assembled monolayer of perdeuterated octadecanethiol on gold and an overlying leaflet of acyl-deuterated phosphatidylcholine (d-DMPC). Using contrast variation, several reflectivity spectra were recorded for each step of film fabrication, and simultaneously modeled. This analysis indicated that peptide insertion into the DMPC lipid leaflet is the likeliest mode of incorporation. PMID:21274414

  9. Cryptococcus neoformans Virulence Gene Discovery through Insertional Mutagenesis

    PubMed Central

    Idnurm, Alexander; Reedy, Jennifer L.; Nussbaum, Jesse C.; Heitman, Joseph

    2004-01-01

    Insertional mutagenesis was applied to Cryptococcus neoformans to identify genes associated with virulence attributes. Using biolistic transformation, we generated 4,300 nourseothricin (NAT)-resistant strains, of which 590 exhibited stable resistance. We focused on mutants with defects in established virulence factors and identified two with reduced growth at 37°C, four with reduced production of the antioxidant pigment melanin, and two with an increased sensitivity to nitric oxide (NO). The NAT insertion and mutant phenotypes were genetically linked in five of eight mutants, and the DNA flanking the insertions was characterized. For the strains with altered growth at 37°C and altered melanin production, mutations were in previously uncharacterized genes, while the two NO-sensitive strains bore insertions in the flavohemoglobin gene FHB1, whose product counters NO stress. Because of the frequent instability of nourseothricin resistance associated with biolistic transformation, Agrobacterium-mediated transformation was tested. This transkingdom DNA delivery approach produced 100% stable nourseothricin-resistant transformants, and three melanin-defective strains were identified from 576 transformants, of which 2 were linked to NAT in segregation analysis. One of these mutants contained a T-DNA insertion in the promoter of the LAC1 (laccase) gene, which encodes a key enzyme required for melanin production, while the second contained an insertion in the promoter of the CLC1 gene, encoding a voltage-gated chloride channel. Clc1 and its homologs are required for ion homeostasis, and in their absence Cu+ transport into the secretory pathway is compromised, depriving laccase and other Cu+-dependent proteins of their essential cofactor. The NAT resistance cassette was optimized for cryptococcal codon usage and GC content and was then used to disrupt a mitogen-activated protein kinase gene, a predicted gene, and two putative chloride channel genes to analyze their

  10. Insertion of lithium into electrochromic devices after completion

    DOEpatents

    Berland, Brian Spencer; Lanning, Bruce Roy; Frey, Jonathan Mack; Barrett, Kathryn Suzanne; DuPont, Paul Damon; Schaller, Ronald William

    2015-12-22

    The present disclosure describes methods of inserting lithium into an electrochromic device after completion. In the disclosed methods, an ideal amount of lithium can be added post-fabrication to maximize or tailor the free lithium ion density of a layer or the coloration range of a device. Embodiments are directed towards a method to insert lithium into the main device layers of an electrochromic device as a post-processing step after the device has been manufactured. In an embodiment, the methods described are designed to maximize the coloration range while compensating for blind charge loss.

  11. Magnetic ripple correction in tandem mirrors by ferromagnetic inserts

    SciTech Connect

    Hamilton, G.W.

    1985-04-04

    Magnetic ripple of 1% or more caused by discrete solenoid coils in the central cells of tandem mirrors may severely affect the MHD stability. The ripple amplitude can be reduced by an order of magnitude by ferromagnetic annuli inserted within the coils at the regions of ripple maxima. The inserts need not affect the accessibility, coil diameter, or capital cost, since large quantities of steel are required within the coils for the neutron blanket and shield. Design of the ripple correction is simplified and linearized by the cylindrical geometry and by the saturation of the ferromagnetic steel.

  12. 20 TeV collider lattices with low-. beta. insertions

    SciTech Connect

    Garren, A.A.

    1983-08-01

    A lattice containing insertions designed for collisions of 20 TeV proton beams at crossing points having beta values of two meters or less is presented. The machine would use high-field double bore superconducting magnets, with opposite focusing action on the two beams passing through each quadrupole. Hence the focusing pattern in the insertions is antisymmetric about the crossings. The beams, separated by 16 cms in the arcs are made colinear by dipoles common to both beams and then focused to the low-..beta.. collision points by quadrupole triplets. A similar machine design for pp collisions is also included.

  13. Tension Pneumothorax and Subcutaneous Emphysema Complicating Insertion of Nasogastric Tube

    PubMed Central

    AL Saif, Narjis; Al-Azem, M. Ali; Al-Hubail, Rasheed

    2015-01-01

    Nasogastric tube has a key role in the management of substantial number of hospitalized patients particularly the critically ill. In spite of the apparent simple insertion technique, nasogastric tube placement has its serious perhaps fatal complications which need to be carefully assessed. Pulmonary misplacement and associated complications are commonplace during nasogastric tube procedure. We present a case of tension pneumothorax and massive surgical emphysema in critically ill ventilated patient due to inadvertent nasogastric tube insertion and also discussed the risk factors, complication list, and arrays of techniques for safer tube placement. PMID:26448883

  14. Tension Pneumothorax and Subcutaneous Emphysema Complicating Insertion of Nasogastric Tube.

    PubMed

    Al Saif, Narjis; Hammodi, Adel; Al-Azem, M Ali; Al-Hubail, Rasheed

    2015-01-01

    Nasogastric tube has a key role in the management of substantial number of hospitalized patients particularly the critically ill. In spite of the apparent simple insertion technique, nasogastric tube placement has its serious perhaps fatal complications which need to be carefully assessed. Pulmonary misplacement and associated complications are commonplace during nasogastric tube procedure. We present a case of tension pneumothorax and massive surgical emphysema in critically ill ventilated patient due to inadvertent nasogastric tube insertion and also discussed the risk factors, complication list, and arrays of techniques for safer tube placement.

  15. Imaging of the complications of peripherally inserted central venous catheters.

    PubMed

    Amerasekera, S S H; Jones, C M; Patel, R; Cleasby, M J

    2009-08-01

    Peripherally inserted central catheters (PICC) are widely used to provide central venous access, often in chronically ill patients with long-term intravenous access requirements. There are a number of significant complications related to both insertion and maintenance of PICC lines, including catheter malposition, migration, venous thrombosis, and line fracture. The incidence of these complications is likely to rise as the number of patients undergoing intravenous outpatient therapy increases, with a corresponding rise in radiologist input. This paper provides an overview of the relevant peripheral and central venous anatomy, including anatomical variations, and outlines the complications of PICC lines. Imaging examples demonstrate the range of radiological findings seen in these complications.

  16. Rays inserting method (RIM) to design dielectric optical devices

    NASA Astrophysics Data System (ADS)

    Taskhiri, Mohammad Mahdi; Khalaj Amirhosseini, Mohammad

    2017-01-01

    In this article, a novel approach, called Rays Inserted Method (RIM), is introduced to design dielectric optical devices. In this approach, some rays are inserted between two ends of desired device and then the refractive index of the points along the route of rays are obtained. The validity of the introduced approach is verified by designing three types of optical devices, i.e. power splitter, bend, and flat lens. The results are confirmed with numerical simulations by the means of FDTD scheme at the frequency of 100 GHz.

  17. Technology Insertion and Management: Options for the Canadian Forces

    DTIC Science & Technology

    2010-01-01

    enhancement” of system performance and functionality in existing or deployed defence systems by the utilization of a new or improved technology. Importantly...du fardeau logistique si l’insertion technologique est mise en œuvre de façon efficace. La réduction des coûts de propriété d’un système de défense...powerful Honeywell engines that improve fuel efficiency and enhance lift performance by 3900lbs. [7] Horizontal technology insertion (HTI) refers to

  18. Synthesis and characterization of conducting polymer inserted carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Choi, A. Jeong; Nam, Young Woo; Park, Yung Woo

    2008-03-01

    The carbon nanotubes filled with the photo-conducting polymer poly(N-vinyl carbazole) and the conducting polymer polypyrrole were prepared by polymerizing the monomers inside the nanotubes using the supercritical carbon dioxide. The endohedral nanotubes were characterized by HRTEM and ^1H NMR, which confirmed that the inserted material was indeed the conducting polymer [1]. I-V characteristics of the polymer inserted carbon nanotubes are presented. [1] Johannes Steinmetz, Soyoung Kwon, Hyun-Jung Lee, Edy Abou-Hamad, Robert Almairac, Christophe Goze-Bac, Hwayong Kim, Yung-Woo Park,, Chem. Phys. Lett., 431, 139 (2006)

  19. Rectal fist insertion. An unusual form of sexual behavior.

    PubMed

    Shook, L L; Whittle, R; Rose, E F

    1985-12-01

    Rectal fist insertion (fist fucking) is an uncommon and potentially dangerous sexual practice. This is usually a homosexual activity, but can also be a heterosexual or an autoerotic practice. One known death has been reported associated with rectal fist insertion, in which the complications of anal and colonic tears and bleeding had occurred (see Editor's note). The possibility of drug overdose is also probable, as drugs and alcohol are commonly introduced into the rectum to promote sphincter relaxation and to ease the discomfort of anal dilatation.

  20. Advanced photon source experience with vacuum chambers for insertion devices

    SciTech Connect

    Hartog, P.D.; Grimmer, J.; Xu, S.; Trakhtenberg, E.; Wiemerslage, G.

    1997-08-01

    During the last five years, a new approach to the design and fabrication of extruded aluminum vacuum chambers for insertion devices was developed at the Advanced Photon Source (APS). With this approach, three different versions of the vacuum chamber, with vertical apertures of 12 mm, 8 mm, and 5 mm, were manufactured and tested. Twenty chambers were installed into the APS vacuum system. All have operated with beam, and 16 have been coupled with insertion devices. Two different vacuum chambers with vertical apertures of 16 mm and 11 mm were developed for the BESSY-II storage ring and 3 of 16 mm chambers were manufactured.

  1. Dosimetry of portable image intensifiers in pacemaker insertions.

    PubMed

    Hayt, D B; Malsky, S J; Blatt, C J; Greenberg, E I; Pochaczevsky, R; Simon, D F; Perez, L A

    1975-01-01

    With the increased utilization of portable image intensifiers for pacemaker insertions, an investigation of the radiation hazards to operative personnel was undertaken. The personnel were tested first utilizing a Rando phantom and later during actual pacemaker insertions. Studies of medical personnel show the critical organs to be the thyroid (approximately 15mR per procedure) and the lens of the eye (approximately 13mR per procedure). While the MPD/week was not exceeded, the radiation dosage was substantial and could increase under operating conditions other than those measured. Recommendations to insure safer operation of this equipment are presented.

  2. Insert earphones for audiometry: applications, advantages, and limitations.

    PubMed

    Luks, S B; Borton, T E; Nolen, B L

    1989-09-01

    The measurement of hearing sensitivity during audiometry requires precise presentation of auditory stimuli. In most cases, these stimuli are introduced to the listener via standard earphones. Technical problems associated with these earphones have troubled clinicians for years. An alternative earphone system for audiometry was introduced that uses shoulder-worn transducers with inserts for connection with the external auditory canal. Although insert earphones are not intended to supplant standard earphones, experimental evidence and clinical observations support the advantageousness of these earphones under a variety of clinical conditions.

  3. Removable partial dentures with rotational paths of insertion: problem analysis.

    PubMed

    Firtell, D N; Jacobson, T E

    1983-07-01

    Removable partial dentures designed to use a rotational path of insertion are technique sensitive. When indicated and when the principles discussed are followed, a denture that uses a rotational path can be highly successful. Tooth coverage can be decreased, which is an advantage in plaque control, caries reduction, and periodontal support. Esthetics can be improved without resorting to intracoronal retainers, and the number of components subject to distortion is reduced. When properly designed and constructed, use of a rotational path of insertion can result in a removable partial denture that is strong, hygienic, and esthetic.

  4. Definition of metrics to evaluate cochlear array insertion forces performed with forceps, insertion tool, or motorized tool in temporal bone specimens.

    PubMed

    Nguyen, Yann; Kazmitcheff, Guillaume; De Seta, Daniele; Miroir, Mathieu; Ferrary, Evelyne; Sterkers, Olivier

    2014-01-01

    In order to achieve a minimal trauma to the inner ear structures during array insertion, it would be suitable to control insertion forces. The aim of this work was to compare the insertion forces of an array insertion into anatomical specimens with three different insertion techniques: with forceps, with a commercial tool, and with a motorized tool. Temporal bones have been mounted on a 6-axis force sensor to record insertion forces. Each temporal bone has been inserted, with a lateral wall electrode array, in random order, with each of the 3 techniques. Forceps manual and commercial tool insertions generated multiple jerks during whole length insertion related to fits and starts. On the contrary, insertion force with the motorized tool only rose at the end of the insertion. Overall force momentum was 1.16 ± 0.505 N (mean ± SD, n = 10), 1.337 ± 0.408 N (n = 8), and 1.573 ± 0.764 N (n = 8) for manual insertion with forceps and commercial and motorized tools, respectively. Considering force momentum, no difference between the three techniques was observed. Nevertheless, a more predictable force profile could be observed with the motorized tool with a smoother rise of insertion forces.

  5. Definition of Metrics to Evaluate Cochlear Array Insertion Forces Performed with Forceps, Insertion Tool, or Motorized Tool in Temporal Bone Specimens

    PubMed Central

    Ferrary, Evelyne; Sterkers, Olivier

    2014-01-01

    Introduction. In order to achieve a minimal trauma to the inner ear structures during array insertion, it would be suitable to control insertion forces. The aim of this work was to compare the insertion forces of an array insertion into anatomical specimens with three different insertion techniques: with forceps, with a commercial tool, and with a motorized tool. Materials and Methods. Temporal bones have been mounted on a 6-axis force sensor to record insertion forces. Each temporal bone has been inserted, with a lateral wall electrode array, in random order, with each of the 3 techniques. Results. Forceps manual and commercial tool insertions generated multiple jerks during whole length insertion related to fits and starts. On the contrary, insertion force with the motorized tool only rose at the end of the insertion. Overall force momentum was 1.16 ± 0.505 N (mean ± SD, n = 10), 1.337 ± 0.408 N (n = 8), and 1.573 ± 0.764 N (n = 8) for manual insertion with forceps and commercial and motorized tools, respectively. Conclusion. Considering force momentum, no difference between the three techniques was observed. Nevertheless, a more predictable force profile could be observed with the motorized tool with a smoother rise of insertion forces. PMID:25126565

  6. [Adequacy of the device intrauterine by ultrasound evaluation: postpartum and post-abortion insertion versus insertion during the menstrual cycle].

    PubMed

    de Holanda, Antônio Arildo Reginaldo; Pessoa, Aline de Melo; Holanda, Julita de Campos Pipolo; de Melo, Maria Helena Vieira; Maranhão, Técia Maria de Oliveira

    2013-08-01

    To compare by transvaginal ultrasound the position of the intrauterine device (IUD) inside the uterine cavity, depending on the time of insertion, postpartum and post-abortion, and during the menstrual cycle. Epidemiologic, observational and cross-sectional study carried out between February and July, 2013. A total of 290 women were included, 205 of them with insertion during the menstrual cycle and 85 during the postpartum and post-abortion periods. The independent variables were: age, parity, time of use, insertion time, number of returns to family planning, satisfaction with the method, wish to continue using the device, symptoms and complications. The dependent variable was the adequate position of the IUD inside the uterine cavity. The χ² test with Pearson's correction and the Fisher exact test were used for statistical analysis, with the level of significance set at 5%. The average age was 29.4 years and the average time of IUD use was 2.7 years; 39.3% of the women had symptoms associated with the method, the most frequent being menorrhagia (44.7%). The degree of satisfaction was 85% and 61.4% of the women returned two or more times for consultation about family planning. Age, parity and the position of the uterus in the pelvic cavity was not associated with a poor position of the IUD inside the uterine cavity (p>0.05). Insertion during the menstrual cycle was significantly more associated with a correct position of the IUD than postpartum and post-abortion insertion (p<0.028). Postpartum and post-abortion insertion showed worse results regarding the adequacy of IUD position, a fact that was not observed regarding age, parity or position of the uterus in the pelvic cavity.

  7. Teaching self-administration of nasogastric tube insertion to an adolescent with Crohn disease.

    PubMed Central

    Reimers, T M; Vance, M D; Young, R J

    1995-01-01

    We examined the effectiveness of simulation training to teach an adolescent male with Crohn disease to self-administer nasogastric tube insertion. Nasogastric tube insertion was taught using simulation training, after which self-insertion skills were assessed. Results across skill components indicated that this subject was able to self-administer insertion of the nasogastric tube. PMID:7601807

  8. Analysis of HIV-2 Vpx by modeling and insertional mutagenesis

    SciTech Connect

    Mahnke, Lisa A. . E-mail: lmahnke@im.wustl.edu; Belshan, Michael; Ratner, Lee . E-mail: lratner@im.wustl.edu

    2006-04-25

    Vpx facilitates HIV-2 nuclear localization by a poorly understood mechanism. We have compared Vpx to an NMR structure HIV-1 Vpr in a central helical domain and probed regions of Vpx by insertional mutagenesis. A predicted loop between helices two and three appears to be unique, overlapping with a known novel nuclear localization signal. Overall, Vpx was found to be surprisingly flexible, tolerating a series of large insertions. We found that insertion within the polyproline-containing C-terminus destabilizes nuclear localization, whereas mutating a second helix in the central domain disrupts viral packaging. Other insertional mutants in the predicted loop and in a linker region between the central domain and the C-terminus may be useful as sites of intramolecular tags as they could be packaged adequately and retained preintegration complex associated integration activity in a serum starvation assay. An unexpected result was found within a previously defined nuclear localization motif near aa 71. This mutant retained robust nuclear localization in a GFP fusion assay and was competent for preintegration complex associated nuclear import. In summary, we have modeled helical content in Vpx and assessed potential sites of intramolecular tags which may prove useful for protein-protein interactions studies.

  9. ETTF - Apt inserts sample into experiment in Spacehab

    NASA Image and Video Library

    1996-09-17

    STS79-E-5018 (17 September 1996) --- Astronaut Jerome (Jay) Apt prepares experiment, a rod-like device for insertion into Extreme Temperature Translation Furnace (ETTF) in STS-79-E-5019, during early mission chores aboard Spacehab in the Space Shuttle Atlantis cargo bay, on Flight Day 2.

  10. Discovery of unfixed endogenous retrovirus insertions in diverse human populations

    PubMed Central

    Wildschutte, Julia Halo; Williams, Zachary H.; Montesion, Meagan; Subramanian, Ravi P.; Kidd, Jeffrey M.; Coffin, John M.

    2016-01-01

    Endogenous retroviruses (ERVs) have contributed to more than 8% of the human genome. The majority of these elements lack function due to accumulated mutations or internal recombination resulting in a solitary (solo) LTR, although members of one group of human ERVs (HERVs), HERV-K, were recently active with members that remain nearly intact, a subset of which is present as insertionally polymorphic loci that include approximately full-length (2-LTR) and solo-LTR alleles in addition to the unoccupied site. Several 2-LTR insertions have intact reading frames in some or all genes that are expressed as functional proteins. These properties reflect the activity of HERV-K and suggest the existence of additional unique loci within humans. We sought to determine the extent to which other polymorphic insertions are present in humans, using sequenced genomes from the 1000 Genomes Project and a subset of the Human Genome Diversity Project panel. We report analysis of a total of 36 nonreference polymorphic HERV-K proviruses, including 19 newly reported loci, with insertion frequencies ranging from <0.0005 to >0.75 that varied by population. Targeted screening of individual loci identified three new unfixed 2-LTR proviruses within our set, including an intact provirus present at Xq21.33 in some individuals, with the potential for retained infectivity. PMID:27001843

  11. Mitochondrial DNA insertions in the nuclear horse genome.

    PubMed

    Nergadze, S G; Lupotto, M; Pellanda, P; Santagostino, M; Vitelli, V; Giulotto, E

    2010-12-01

    The insertion of mitochondrial DNA in the nuclear genome generates numts, nuclear sequences of mitochondrial origin. In the horse reference genome, we identified 82 numts and showed that the entire horse mitochondrial DNA is represented as numts without gross bias. Numts were inserted in the horse nuclear genome at random sites and were probably generated during the repair of DNA double-strand breaks. We then analysed 12 numt loci in 20 unrelated horses and found that null alleles, lacking the mitochondrial DNA insertion, were present at six of these loci. At some loci, the null allele is prevalent in the sample analysed, suggesting that, in the horse population, the number of numt loci may be higher than 82 present in the reference genome. Contrary to humans, the insertion polymorphism of numts is extremely frequent in the horse population, supporting the hypothesis that the genome of this species is in a rapidly evolving state. © 2010 The Authors, Journal compilation © 2010 Stichting International Foundation for Animal Genetics.

  12. Effects of Rotational Motion in Robotic Needle Insertion

    PubMed Central

    Ramezanpour, H.; Yousefi, H.; Rezaei, M.; Rostami, M.

    2015-01-01

    Background Robotic needle insertion in biological tissues has been known as one the most applicable procedures in sampling, robotic injection and different medical therapies and operations. Objective In this paper, we would like to investigate the effects of angular velocity in soft tissue insertion procedure by considering force-displacement diagram. Non-homogenous camel liver can be exploited as a tissue sample under standard compression test with Zwick/Roell device employing 1-D axial load-cell. Methods Effects of rotational motion were studied by running needle insertion experiments in 5, 50 and 200 mm/min in two types of with or without rotational velocity of 50, 150 and 300 rpm. On further steps with deeper penetrations, friction force of the insertion procedure in needle shaft was acquired by a definite thickness of the tissue. Results Designed mechanism of fixture for providing different frequencies of rotational motion is available in this work. Results for comparison of different force graphs were also provided. Conclusion Derived force-displacement graphs showed a significant difference between two procedures; however, tissue bleeding and disorganized micro-structure would be among unavoidable results. PMID:26688800

  13. Prediction tool for thrombi associated with peripherally inserted central catheters.

    PubMed

    Seeley, Maria A; Santiago, Mary; Shott, Susan

    2007-01-01

    The upper extremity deep vein thrombosis rate is increasing at the same time that the rate for insertions of peripherally inserted central catheters is on the rise. There is little information on whether the established risk factors for lower extremity deep vein thromboses are effective to predict the occurrence of upper extremity deep vein thrombosis. The purpose of this study was to identify patients at highest risk for upper extremity deep vein thrombosis in order to initiate effective prophylaxis. A retrospective review was undertaken of medical records of all patients with peripherally inserted central catheters inserted in a 6-month period at a Midwestern US hospital. Of the 233 charts reviewed, 17 (7.3%) recorded an upper extremity deep vein thrombosis during the patient's hospital stay. Of the multiple factors identified with deep vein thrombosis in the literature, a weighted risk factor measure, the upper extremity deep vein thrombosis prediction tool, was developed. Sensitivity of the instrument for upper extremity deep vein thrombosis is high (88%), as are its specificity (82%) and negative predictive value (99%), whereas the positive predictive value is low (28%). The total percentage of cases correctly classified is 82%. Further testing is indicated on a larger sample to extend the validity of this instrument.

  14. Folding and insertion thermodynamics of the transmembrane WALP peptide

    NASA Astrophysics Data System (ADS)

    Bereau, Tristan; Bennett, W. F. Drew; Pfaendtner, Jim; Deserno, Markus; Karttunen, Mikko

    2015-12-01

    The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA)n (L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural properties have been illuminated in a large number of experimental and simulation studies. In this combined coarse-grained and atomistic simulation study, we probe the thermodynamics of a single WALP peptide, focusing on both the insertion across the water-membrane interface, as well as folding in both water and a membrane. The potential of mean force characterizing the peptide's insertion into the membrane shows qualitatively similar behavior across peptides and three force fields. However, the Martini force field exhibits a pronounced secondary minimum for an adsorbed interfacial state, which may even become the global minimum—in contrast to both atomistic simulations and the alternative PLUM force field. Even though the two coarse-grained models reproduce the free energy of insertion of individual amino acids side chains, they both underestimate its corresponding value for the full peptide (as compared with atomistic simulations), hinting at cooperative physics beyond the residue level. Folding of WALP in the two environments indicates the helix as the most stable structure, though with different relative stabilities and chain-length dependence.

  15. Quench Module Insert Capabilities and Development Test Results

    NASA Technical Reports Server (NTRS)

    Carswell, B.; Crouch, M.; Farmer, J.; Breeding, S.; Rose, F.; Whitaker, Ann F. (Technical Monitor)

    2001-01-01

    Quench Module Insert is a directional solidification furnace, which will fly in the Materials Science Research Facility. The QMI provides high thermal gradient and quench capabilities for processing metals and alloys in microgravity. This paper will describe the capabilities and present of on-going analysis and development testing.

  16. Indentation and needle insertion properties of the human eye

    PubMed Central

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-01-01

    Purpose Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. Methods An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. Results The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (P<0.001). Needle insertion through the anterior sclera (adjacent to the limbus) and posterior sclera (adjacent to the optic nerve) required the greatest amount of force (0.954 and 1.005 N, respectively). The force required to penetrate the central cornea (0.518 N) was significantly lower than all other areas except the midline sclera (0.700 N) Conclusion These data form the basis for further research into the development of a tissue-mimicking human eye construct with potential utility as a model for use in ophthalmology research and surgical teaching. PMID:24810571

  17. Hadfield prepares to insert biological samples in the MELFI-1

    NASA Image and Video Library

    2013-01-07

    View of Canadian Space Agency (CSA) Chris Hadfield,Expedition 34 Flight Engineer (FE),preparing to insert biological samples in the Minus Eighty Laboratory Freezer for International Space Station (ISS) - (MELFI-1),in the Japanese Experiment Module (JEM) Pressurized Module (JPM). Photo was taken during Expedition 34.

  18. Spline modelling electron insert factors using routine measurements.

    PubMed

    Biggs, S; Sobolewski, M; Murry, R; Kenny, J

    2016-01-01

    There are many methods available to predict electron output factors; however, many centres still measure the factors for each irregular electron field. Creating an electron output factor prediction model that approaches measurement accuracy--but uses already available data and is simple to implement--would be advantageous in the clinical setting. This work presents an empirical spline model for output factor prediction that requires only the measured factors for arbitrary insert shapes. Equivalent ellipses of the insert shapes are determined and then parameterised by width and ratio of perimeter to area. This takes into account changes in lateral scatter, bremsstrahlung produced in the insert material, and scatter from the edge of the insert. Agreement between prediction and measurement for the 12 MeV validation data had an uncertainty of 0.4% (1SD). The maximum recorded deviation between measurement and prediction over the range of energies was 1.0%. The validation methodology showed that one may expect an approximate uncertainty of 0.5% (1SD) when as little as eight data points are used. The level of accuracy combined with the ease with which this model can be generated demonstrates its suitability for clinical use. Implementation of this method is freely available for download at https://github.com/SimonBiggs/electronfactors.

  19. Folding and insertion thermodynamics of the transmembrane WALP peptide

    SciTech Connect

    Bereau, Tristan; Bennett, W. F. Drew; Pfaendtner, Jim; Deserno, Markus; Karttunen, Mikko

    2015-12-28

    The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA){sub n} (L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural properties have been illuminated in a large number of experimental and simulation studies. In this combined coarse-grained and atomistic simulation study, we probe the thermodynamics of a single WALP peptide, focusing on both the insertion across the water-membrane interface, as well as folding in both water and a membrane. The potential of mean force characterizing the peptide’s insertion into the membrane shows qualitatively similar behavior across peptides and three force fields. However, the Martini force field exhibits a pronounced secondary minimum for an adsorbed interfacial state, which may even become the global minimum—in contrast to both atomistic simulations and the alternative PLUM force field. Even though the two coarse-grained models reproduce the free energy of insertion of individual amino acids side chains, they both underestimate its corresponding value for the full peptide (as compared with atomistic simulations), hinting at cooperative physics beyond the residue level. Folding of WALP in the two environments indicates the helix as the most stable structure, though with different relative stabilities and chain-length dependence.

  20. New transposon delivery plasmids for insertional mutagenesis in Bacillus anthracis

    PubMed Central

    Wilson, Adam C.; Perego, Marta; Hoch, James A.

    2007-01-01

    Two new transposon delivery vector systems utilizing Mariner and mini-Tn10 transposons have been developed for in vivo insertional mutagenesis in Bacillus anthracis and other compatible Gram-positive species. The utility of both systems was directly demonstrated through the mutagenesis of a widely used B. anthracis strain. PMID:17931726

  1. Proper Angle of Sono-guided Central Venous Line Insertion

    PubMed Central

    Barzegari, Hassan; Forouzan, Arash; Fahimi, Mohammad Ali; Zohrevandi, Behzad; Ghanavati, Mandana

    2016-01-01

    Introduction: Determining the proper angle for inserting central venous catheter (CV line) is of great importance for decreasing the complications and increasing success rate. The present study was designed to determine the proper angle of needle insertion for internal jugular vein catheterization. Methods: In the present case series study, candidate patients for catheterization of the right internal jugular vein under guidance of ultrasonography were studied. At the time of proper placing of the catheter, photograph was taken and Auto Cad 2014 software was used to measure the angles of the needle in the sagittal and axial planes, as well as patient’s head rotation. Result: 114 patients with the mean age of 56.96 ± 14.71 years were evaluated (68.4% male). The most common indications of catheterization were hemodialysis (55.3%) and shock state (24.6%). The mean angles of needle insertion were 102.15 ± 6.80 for axial plane, 36.21 ± 3.12 for sagittal plane and the mean head rotation angle was 40.49 ± 5.09. Conclusion: Based on the results of the present study it seems that CV line insertion under the angles 102.15 ± 6.80 degrees in the axial plane, 36.21 ± 3.12 in the sagittal plane and 40.49 ± 5.09 head rotation yield satisfactory results. PMID:27299146

  2. Spectral analysis of hearing protector impulsive insertion loss.

    PubMed

    Fackler, Cameron J; Berger, Elliott H; Murphy, William J; Stergar, Michael E

    2017-01-01

    To characterise the performance of hearing protection devices (HPDs) in impulsive-noise conditions and to compare various protection metrics between impulsive and steady-state noise sources with different characteristics. HPDs were measured per the impulsive test methods of ANSI/ASA S12.42- 2010 . Protectors were measured with impulses generated by both an acoustic shock tube and an AR-15 rifle. The measured data were analysed for impulse peak insertion loss (IPIL) and impulsive spectral insertion loss (ISIL). These impulsive measurements were compared to insertion loss measured with steady-state noise and with real-ear attenuation at threshold (REAT). Tested HPDs included a foam earplug, a level-dependent earplug and an electronic sound-restoration earmuff. IPIL for a given protector varied between measurements with the two impulse noise sources, but ISIL agreed between the two sources. The level-dependent earplug demonstrated level-dependent effects both in IPIL and ISIL. Steady-state insertion loss and REAT measurements tended to provide a conservative estimate of the impulsively-measured attenuation. Measurements of IPIL depend strongly on the source used to measure them, especially for HPDs with less attenuation at low frequencies. ISIL provides an alternative measurement of impulse protection and appears to be a more complete description of an HPD's performance.

  3. Gemini 10 prime crew in White Room preparing for insertion

    NASA Image and Video Library

    1966-07-18

    S66-42737 (18 July 1966) --- In the White Room atop the Gemini launch vehicle, astronauts Michael Collins (left), pilot, and John W. Young (right), command pilot, prepare to enter the Gemini-10 spacecraft. Engineers and technicians stand by to assist in the insertion. Photo credit: NASA

  4. HiFocus Helix™ electrode insertion: surgical approach.

    PubMed

    Castilho, Arthur Menino; Pauna, Henrique Furlan; Fernandes, Fernando Laffitte; Bonhin, Rodrigo Gonzales; Guimarães, Alexandre Caixeta; de Melo, Tatiana Mendes; Cheng, Margareth; Sartorato, Edi Lucia; de Carvalho, Guilherme Machado; Paschoal, Jorge Rizzato

    2015-07-15

    Cochlear implants have been used for almost 30 years as a device for the rehabilitation of individuals with severe-to-profound hearing loss. One of the important aspects of cochlear implantation is the type of electrode selected and proper insertion of the electrode array in scala tympani to minimize cochlear damage. The HiFocus Helix™ electrode is a precurved design aimed at placing the electrode contacts close to the spiral ganglion cells in the modiolus. The prescribed insertion techniques are intended to minimize the likelihood of damage to the basilar membrane or lateral wall of the cochlea. To describe the first insertion of a HiFocus Helix™ electrode in Brazil exposing surgical particularities and device details in a patient with profound hearing loss, due to Mondini's dysplasia. No problems were encountered during the surgical procedure. The patient experienced improvement in hearing thresholds and speech perception. The HiFocus Helix™ electrode proved easy to insert and provided expected hearing benefits for the patient. This manuscript indicates that the HiResolution™ Bionic Ear System with HiFocus Helix™ electrode comprise a cochlear implant system that is practical and beneficial for the treatment of severe-to-profound hearing loss.

  5. EMLA cream effectively reduces the pain of spinal needle insertion.

    PubMed

    Sharma, S K; Gajraj, N M; Sidawi, J E; Lowe, K

    1996-01-01

    EMLA cream is an effective topical anesthetic, which is commonly used for analgesia during venous cannulation in the pediatric population. This study was designed to compare the efficacy of EMLA cream with that of infiltration with lidocaine in relieving the pain associated with administration of spinal anesthesia. The patient population consisted of 41 ASA status I and II women scheduled for postpartum tubal ligation. Spinal anesthesia was administered with a 25-gauge spinal needle via a 20-gauge introducer. The patients were randomly allocated to receive either EMLA cream for a minimum of 30 minutes or infiltration with 3 mL of 1% lidocaine prior to spinal needle insertion. Pain during spinal needle insertion was assessed immediately after each procedure by a 10-cm visual analog scale. Pain scores were significantly lower in the EMLA group (mean, 1.5) than in the lidocaine group (mean, 3.52) (P < .001). The number of patients satisfied with the method of analgesia was significantly higher in the EMLA than in the lidocaine group (90% vs 55%, P < .05). EMLA cream is an effective alternative to lidocaine infiltration for analgesia during the administration of spinal anesthesia when using a 25-gauge spinal needle via a 20-gauge introducer. Application of EMLA cream for at least 30 minutes prior to spinal needle insertion is adequate to provide good analgesia during needle insertion.

  6. Computer Modeling of Protocellular Functions: Peptide Insertion in Membranes

    NASA Technical Reports Server (NTRS)

    Rodriquez-Gomez, D.; Darve, E.; Pohorille, A.

    2006-01-01

    Lipid vesicles became the precursors to protocells by acquiring the capabilities needed to survive and reproduce. These include transport of ions, nutrients and waste products across cell walls and capture of energy and its conversion into a chemically usable form. In modem organisms these functions are carried out by membrane-bound proteins (about 30% of the genome codes for this kind of proteins). A number of properties of alpha-helical peptides suggest that their associations are excellent candidates for protobiological precursors of proteins. In particular, some simple a-helical peptides can aggregate spontaneously and form functional channels. This process can be described conceptually by a three-step thermodynamic cycle: 1 - folding of helices at the water-membrane interface, 2 - helix insertion into the lipid bilayer and 3 - specific interactions of these helices that result in functional tertiary structures. Although a crucial step, helix insertion has not been adequately studied because of the insolubility and aggregation of hydrophobic peptides. In this work, we use computer simulation methods (Molecular Dynamics) to characterize the energetics of helix insertion and we discuss its importance in an evolutionary context. Specifically, helices could self-assemble only if their interactions were sufficiently strong to compensate the unfavorable Free Energy of insertion of individual helices into membranes, providing a selection mechanism for protobiological evolution.

  7. Nasogastric tube insertion in anaesthetized patients: a comprehensive review.

    PubMed

    Sanaie, Sarvin; Mahmoodpoor, Ata; Najafi, Mahdi

    2017-01-01

    Nasogastric tubes (NGT) still remain the easiest and the best way for gastrointestinal tract access. There are various indications for the insertion of a nasogastric tube in anaesthetized and critically ill patients. Although many techniques have been introduced to facilitate nasogastric tube insertion using anatomic landmarks and a group of devices, there is no consensus on a standard method. Moreover, there are different methods for the assessment of the correct placement of a nasogastric tube. In addition to these challenges in insertion and assessment methods, there are varieties of major life-threatening and minor complications to be addressed. Thus, selecting the most appropriate approach requires enough knowledge in this area, considering patient condition and clinical factors, as well as the practitioners' sufficient education and experience, along with skill in performance. This is a comprehensive review of the literature evidence on different methods for nasogastric tube insertion, on the assessment of correct placement and the evaluation of complications, in addition to an approach to the effect of education on the quality of routine practice and patients' outcome.  .

  8. PiggyBac Transgene Insertion Site GIZA Strain

    USDA-ARS?s Scientific Manuscript database

    Genetically modified New World screwworms were analyzed by inverse PCR and several sequences of genomic DNA flanking the transposon insertion sites were obtained. One transgenic strain, designated GIZA, exhibited the properties of a lethal genetic mutation. Classic genetic crosses of these insects r...

  9. Insertion Success of the Laryngeal Tube in Emergency Airway Management

    PubMed Central

    Gries, André; Ramshorn-Zimmer, Alexandra; Wenzel, Volker

    2016-01-01

    Background. Emergency airway management (AM) is a priority when resuscitating critically ill or severely injured patients. The goal of this study was to determine the success rates of LT insertion during AM. Methods. Studies that included LT first-pass insertion (FPI) and overall-pass insertion (OPI) success by emergency medical services and in-hospital providers performing AM for emergency situations as well as for scheduled surgery published until July 2014 were searched systematically in Medline. Results. Data of 36 studies (n = 1,897) reported a LT FPI success by physicians of 82.5% with an OPI success of 93.6% (p < 0.001). A cumulative analysis of all 53 studies (n = 3,600) led to FPI and OPI success of 80.1% and 92.6% (p < 0.001), respectively. The results of 26 studies (n = 2,159) comparing the LT with the laryngeal mask airway (LMA) demonstrated a FPI success of 77.0 versus 78.7% (p = 0.36) and an OPI success of 92.2 versus 97.7% (p < 0.001). Conclusion. LT insertion failed in the first attempt in one out of five patients, with an overall failure rate in one out of 14 patients. When compared with the LT, the LMA had a cumulative 5.5% better OPI success rate. PMID:27642595

  10. Large scale screen for transposon insertions into cloned genes.

    PubMed Central

    Hamilton, B A; Palazzolo, M J; Chang, J H; VijayRaghavan, K; Mayeda, C A; Whitney, M A; Meyerowitz, E M

    1991-01-01

    We describe a method of screening for transposon insertions in or near Drosophila loci that correspond to cloned DNA sequences. We mobilize a modified P element transposon that carries a bacterial plasmid origin of replication and a drug-resistance marker. The genomic sequences flanking each transposon insertion site can then be rescued as a plasmid in Escherichia coli. Libraries of such plasmids, representing pools of transposon-mutagenized individuals, are used as hybridization probes against cloned sequences to determine whether a transposon has inserted next to a particular site in the genome. The number of loci that can be screened simultaneously by this procedure is quite large. We have screened an array of cDNA clones representing almost 700 distinct loci against libraries representing 760 mutagenized flies, and we obtained hybridization signals to 7 different cDNAs. Three of these events have been analyzed in detail and represent genuine insertions near genomic sequences that correspond to the cDNAs. Images PMID:1849274

  11. Electromagnetically tracked placement of a peripherally inserted central catheter

    NASA Astrophysics Data System (ADS)

    Sacolick, Laura; Patel, Neilesh; Tang, Jonathan; Levy, Elliot; Cleary, Kevin R.

    2004-05-01

    This paper describes a computer program to utilize electromagnetic tracking guidance during insertion of peripherally inserted central catheters. Placement of a Peripherally Inserted Central Catheter (PICC) line is a relatively simple, routine procedure in which a catheter is inserted into the veins of the lower arm and threaded up the arm to the vena cava to sit just above the heart. However, the procedure requires x-ray verification of the catheter position and is usually done under continuous fluoroscopic guidance. The computer program is designed to replace fluoroscopic guidance in this procedure and make PICC line placement a bedside procedure. This would greatly reduce the time and resources dedicated to this procedure. The physician first goes through a quick registration procedure to register the patient space with the computer screen coordinates. Once registration is completed, the program provides a continuous, real-time display of the position of the catheter tip overlaid on an x-ray image of the patient on an adjacent computer screen. Both the position and orientation of the catheter tip is shown. The display is very similar to that shown when using fluoroscopy.

  12. Insertion Success of the Laryngeal Tube in Emergency Airway Management.

    PubMed

    Bernhard, Michael; Gries, André; Ramshorn-Zimmer, Alexandra; Wenzel, Volker; Hossfeld, Bjoern

    2016-01-01

    Background. Emergency airway management (AM) is a priority when resuscitating critically ill or severely injured patients. The goal of this study was to determine the success rates of LT insertion during AM. Methods. Studies that included LT first-pass insertion (FPI) and overall-pass insertion (OPI) success by emergency medical services and in-hospital providers performing AM for emergency situations as well as for scheduled surgery published until July 2014 were searched systematically in Medline. Results. Data of 36 studies (n = 1,897) reported a LT FPI success by physicians of 82.5% with an OPI success of 93.6% (p < 0.001). A cumulative analysis of all 53 studies (n = 3,600) led to FPI and OPI success of 80.1% and 92.6% (p < 0.001), respectively. The results of 26 studies (n = 2,159) comparing the LT with the laryngeal mask airway (LMA) demonstrated a FPI success of 77.0 versus 78.7% (p = 0.36) and an OPI success of 92.2 versus 97.7% (p < 0.001). Conclusion. LT insertion failed in the first attempt in one out of five patients, with an overall failure rate in one out of 14 patients. When compared with the LT, the LMA had a cumulative 5.5% better OPI success rate.

  13. External Tank (ET) Bipod Fitting Bolted Attachment Locking Insert Performance

    NASA Technical Reports Server (NTRS)

    Larsen, Curtis E.; Wilson, Tim R.; Elliott, Kenny B.; Raju, Ivatury S.; McManamen, John

    2008-01-01

    Following STS-107, the External Tank (ET) Project implemented corrective actions and configuration changes at the ET bipod fitting. Among the corrective actions, the existing bolt lock wire which provided resistance to potential bolt rotation was removed. The lock wire removal was because of concerns with creating voids during foam application and potential for lock wire to become debris. The bolts had been previously lubricated to facilitate assembly but, because of elimination of the lock wire, the ET Project wanted to enable the locking feature of the insert. Thus, the lubrication was removed from bolt threads and instead applied to the washer under the bolt head. Lubrication is necessary to maximize joint pre-load while remaining within the bolt torque specification. The locking feature is implemented by thread crimping in at four places in the insert. As the bolt is torqued into the insert the bolt threads its way past the crimped parts of the insert. This provides the locking of the bolt, as torque is required to loosen the joint after clamping.

  14. Postplacental or delayed levonorgestrel intrauterine device insertion and breastfeeding duration

    PubMed Central

    Chen, Beatrice A.; Reeves, Matthew F.; Creinin, Mitchell D.; Schwarz, E. Bimla

    2011-01-01

    BACKGROUND The objective was to assess the effect of timing of postpartum levonorgestrel-releasing IUD insertion on breastfeeding continuation. STUDY DESIGN Women interested in using a levonorgestrel IUD postpartum were randomized to immediate postplacental insertion (postplacental group) or insertion 6–8 weeks after vaginal delivery (delayed group). Duration and exclusivity of breastfeeding were assessed at 6–8 weeks, 3 months, and 6 months postpartum. Only women who received an IUD were included in this analysis. RESULTS Breastfeeding was initiated by 32/50 (64%) of women receiving a postplacental IUD and 27/46 (58.7%) of women receiving a delayed IUD (p=0.59). More women in the delayed group compared to the postplacental group continued to breastfeed at 6–8 weeks (16/46 vs 15/50, p=0.62), 3 months (13/46 vs 7/50, p=0.13), and 6 months postpartum (11/46 vs 3/50, p=0.02). The results did not differ when only women who initiated breastfeeding or only primiparous women with no prior breastfeeding experience were analyzed. CONCLUSIONS Immediate postplacental insertion of the levonorgestrel IUD is associated with shorter duration of breastfeeding and less exclusive breastfeeding. Further studies are needed of the effects of early initiation of progestin-only methods on women’s lactation experience. PMID:22018124

  15. 30. Photocopy of map. Insert, p. 138, Master Plan Report, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. Photocopy of map. Insert, p. 138, Master Plan Report, 1960, Vol. II. Layton, Layton and Rohrbach, General Planning and Resource Consultants. 1960 MASTER PLAN, SHOWING PROPOSED LOCATION OF LINNAEAN HOUSE - Missouri Botanical Garden, 2345 Tower Grove Avenue, Saint Louis, Independent City, MO

  16. Folding and insertion thermodynamics of the transmembrane WALP peptide.

    PubMed

    Bereau, Tristan; Bennett, W F Drew; Pfaendtner, Jim; Deserno, Markus; Karttunen, Mikko

    2015-12-28

    The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA)n (L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural properties have been illuminated in a large number of experimental and simulation studies. In this combined coarse-grained and atomistic simulation study, we probe the thermodynamics of a single WALP peptide, focusing on both the insertion across the water-membrane interface, as well as folding in both water and a membrane. The potential of mean force characterizing the peptide's insertion into the membrane shows qualitatively similar behavior across peptides and three force fields. However, the Martini force field exhibits a pronounced secondary minimum for an adsorbed interfacial state, which may even become the global minimum-in contrast to both atomistic simulations and the alternative PLUM force field. Even though the two coarse-grained models reproduce the free energy of insertion of individual amino acids side chains, they both underestimate its corresponding value for the full peptide (as compared with atomistic simulations), hinting at cooperative physics beyond the residue level. Folding of WALP in the two environments indicates the helix as the most stable structure, though with different relative stabilities and chain-length dependence.

  17. Insertional mutagenesis using Tnt1 retrotransposon in potato

    USDA-ARS?s Scientific Manuscript database

    Potato is the third most important food crop in the world. However, genetics and genomics research of potato has lagged behind many major crop species due to its autotetraploidy and a highly heterogeneous genome. Insertional mutagenesis using T-DNA or transposable elements, which is available in sev...

  18. Effects of lithium insertion on thermal conductivity of silicon nanowires

    NASA Astrophysics Data System (ADS)

    Xu, Wen; Zhang, Gang; Li, Baowen

    2015-04-01

    Recently, silicon nanowires (SiNWs) have been applied as high-performance Li battery anodes, since they can overcome the pulverization and mechanical fracture during lithiation. Although thermal stability is one of the most important parameters that determine safety of Li batteries, thermal conductivity of SiNWs with Li insertion remains unclear. In this letter, using molecular dynamics simulations, we study room temperature thermal conductivity of SiNWs with Li insertion. It is found that compared with the pristine SiNW, there is as much as 60% reduction in thermal conductivity with 10% concentration of inserted Li atoms, while under the same impurity concentration the reduction in thermal conductivity of the mass-disordered SiNW is only 30%. With lattice dynamics calculations and normal mode decomposition, it is revealed that the phonon lifetimes in SiNWs decrease greatly due to strong scattering of phonons by vibrational modes of Li atoms, especially for those high frequency phonons. The observed strong phonon scattering phenomenon in Li-inserted SiNWs is similar to the phonon rattling effect. Our study serves as an exploration of thermal properties of SiNWs as Li battery anodes or weakly coupled with impurity atoms.

  19. Astronaut Scott Carpenter inserted into Aurora 7 spacecraft

    NASA Technical Reports Server (NTRS)

    1962-01-01

    Astronaut M. Scott Carpenter, pilot of the Mercury-Atlas 7 space flight, is inserted into Aurora 7 spacecraft during the prelaunch countdown. Carpenter is assisted into the spacecraft by Astronaut John Glenn and Gunter Vendt, McDonnell Douglas pad capsule test conducter.

  20. Magnesium oxide inserts for the LECO Carbon Analyzer

    SciTech Connect

    Bagaasen, L.M.; Jensen, C.M.

    1991-01-16

    LECO carbon analysis of plutonium metal and plutonium oxide at the Rocky Flats Plant generates several hundred kilograms of high silica residues each year. The plutonium in these residues is difficult and expensive to recover using production dissolution processes. A magnesium oxide (MgO) insert has been developed that significantly lowers the plutonium recovery costs without adversely affecting accuracy of the carbon analysis.

  1. Insertion of short transmembrane helices by the Sec61 translocon.

    PubMed

    Jaud, Simon; Fernández-Vidal, Mónica; Nilsson, Ingmarie; Meindl-Beinker, Nadja M; Hübner, Nadja C; Tobias, Douglas J; von Heijne, Gunnar; White, Stephen H

    2009-07-14

    The insertion efficiency of transmembrane (TM) helices by the Sec61 translocon depends on helix amino acid composition, the positions of the amino acids within the helix, and helix length. We have used an in vitro expression system to examine systematically the insertion efficiency of short polyleucine segments (L(n), n = 4 ... 12) flanked at either end by 4-residue sequences of the form XXPX-L(n)-XPXX with X = G, N, D, or K. Except for X = K, insertion efficiency (p) is <10% for n < 8, but rises steeply to 100% for n = 12. For X = K, p is already close to 100% for n = 10. A similar pattern is observed for synthetic peptides incorporated into oriented phospholipid bilayer arrays, consistent with the idea that recognition of TM segments by the translocon critically involves physical partitioning of nascent peptide chains into the lipid bilayer. Molecular dynamics simulations suggest that insertion efficiency is determined primarily by the energetic cost of distorting the bilayer in the vicinity of the TM helix. Very short lysine-flanked leucine segments can reduce the energetic cost by extensive hydrogen bonding with water and lipid phosphate groups (snorkeling) and by partial unfolding.

  2. Kuipers prepares to insert biological samples in the MELFI

    NASA Image and Video Library

    2012-02-09

    ISS030-E-116886 (9 Feb. 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, prepares to insert biological samples in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.

  3. Hadfield prepares to insert biological samples in the MELFI-1

    NASA Image and Video Library

    2013-01-07

    ISS034-E-023771 (7 Jan. 2013) --- Canadian Space Agency astronaut Chris Hadfield, Expedition 34 flight engineer, prepares to insert biological samples in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.

  4. Hadfield prepares to insert biological samples in the MELFI-1

    NASA Image and Video Library

    2013-01-07

    ISS034-E-023768 (7 Jan. 2013) --- Canadian Space Agency astronaut Chris Hadfield, Expedition 34 flight engineer, prepares to insert biological samples in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.

  5. Hadfield prepares to insert biological samples in the MELFI-1

    NASA Image and Video Library

    2013-01-07

    ISS034-E-023786 (7 Jan. 2013) --- Canadian Space Agency astronaut Chris Hadfield, Expedition 34 flight engineer, prepares to insert biological samples in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station. Russian cosmonaut Roman Romanenko, flight engineer, is visible near Hadfield.

  6. Kuipers prepares to insert biological samples in the MELFI

    NASA Image and Video Library

    2012-02-09

    ISS030-E-116879 (9 Feb. 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, prepares to insert biological samples in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.

  7. Kuipers prepares to insert biological samples in the MELFI

    NASA Image and Video Library

    2012-02-09

    ISS030-E-116878 (9 Feb. 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, prepares to insert biological samples in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.

  8. Spectral analysis of hearing protector impulsive insertion loss

    PubMed Central

    Fackler, Cameron J.; Berger, Elliott H.; Murphy, William J.; Stergar, Michael E.

    2017-01-01

    Objective To characterize the performance of hearing protection devices in impulsive-noise conditions and to compare various protection metrics between impulsive and steady-state noise sources with different characteristics. Design Hearing protectors were measured per the impulsive test methods of ANSI/ASA S12.42-2010. Protectors were measured with impulses generated by both an acoustic shock tube and an AR-15 rifle. The measured data were analyzed for impulse peak insertion loss (IPIL) and impulsive spectral insertion loss (ISIL). These impulsive measurements were compared to insertion loss measured with steady-state noise and with real-ear attenuation at threshold (REAT). Study Sample Tested devices included a foam earplug, a level-dependent earplug, and an electronic sound-restoration earmuff. Results IPIL for a given protector varied between measurements with the two impulse noise sources, but ISIL agreed between the two sources. The level-dependent earplug demonstrated level-dependent effects both in IPIL and ISIL. Steady-state insertion loss and REAT measurements tended to provide a conservative estimate of the impulsively-measured attenuation. Conclusions Measurements of IPIL depend strongly on the source used to measure them, especially for hearing protectors with less attenuation at low frequencies. ISIL provides an alternative measurement of impulse protection and appears to be a more complete description of an HPD’s performance. PMID:27885881

  9. Selective insertion of sulfur dioxide reduction intermediates on graphene oxide.

    PubMed

    Humeres, Eduardo; Debacher, Nito A; Smaniotto, Alessandra; de Castro, Karen M; Benetoli, Luís O B; de Souza, Eduardo P; Moreira, Regina de F P M; Lopes, Cristiane N; Schreiner, Wido H; Canle, Moisés; Santaballa, J Arturo

    2014-04-22

    Graphite microparticles (d50 6.20 μm) were oxidized by strong acids, and the resultant graphite oxide was thermally exfoliated to graphene oxide sheets (MPGO, C/O 1.53). Graphene oxide was treated with nonthermal plasma under a SO2 atmosphere at room temperature. The XPS spectrum showed that SO2 was inserted only as the oxidized intermediate at 168.7 eV in the S 2p region. Short thermal shocks at 600 and 400 °C, under an Ar atmosphere, produced reduced sulfur and carbon dioxide as shown by the XPS spectrum and TGA analysis coupled to FTIR. MPGO was also submitted to thermal reaction with SO2 at 630 °C, and the XPS spectrum in the S 2p region at 164.0 eV showed that this time only the nonoxidized episulfide intermediate was inserted. Plasma and thermal treatment produced a partial reduction of MPGO. The sequence of thermal reaction followed by plasma treatment inserted both sulfur intermediates. Because oxidized and nonoxidized intermediates have different reactivities, this selective insertion would allow the addition of selective types of organic fragments to the surface of graphene oxide.

  10. Insert earphone modeling and measurement by IEC-60711 coupler.

    PubMed

    Huang, Chen-Hung; Pawar, S; Hong, Zih-Jyun; Huang, Jin

    2011-02-01

    In this study, an analytical model based on the equivalent circuit method is developed to simulate the frequency response of an insert earphone. This earphone incorporates a miniature loudspeaker commonly used in computer, communication, consumer, and car electronics. Through the laser triangulation method, electroacoustic parameters of a miniature loudspeaker are obtained. Several earphone design configurations are analyzed in accordance with the open and closed states of front leakage hole, vent, and back leakage hole. To validate the analysis, an insert earphone that is attached to IEC-60711 coupler and a specially designed fixture tube is experimentally measured for frequency response using electroacoustic equipment in the air. Simulation and experimental results show good agreement over the complete audible frequency range. Analysis indicates that states of front leakage hole, vent, and back leakage hole of an insert earphone have significant effects on frequency response. The front leakage hole affects the low frequency response, whereas the vent affects the fundamental resonance. Detailed analysis has been provided to further improve the design of insert earphones.

  11. Reference thresholds for EARTONE 3A insert earphones.

    PubMed

    Poulsen, T

    1991-01-01

    Hearing threshold determinations have been performed with EARTONE 3A insert earphones and compared with threshold measurements performed with TDH 39 supra-aural earphones. 22 normal hearing subjects participated. Results are given as SPL values measured in an acoustic coupler (IEC 126) and an occluded-ear simulator (IEC 711).

  12. Observations on rotating needle insertions using a brachytherapy robot

    NASA Astrophysics Data System (ADS)

    Meltsner, M. A.; Ferrier, N. J.; Thomadsen, B. R.

    2007-09-01

    A robot designed for prostate brachytherapy implantations has the potential to greatly improve treatment success. Much of the research in robotic surgery focuses on measuring accuracy. However, there exist many factors that must be optimized before an analysis of needle placement accuracy can be determined. Some of these parameters include choice of the needle type, insertion velocity, usefulness of the rotating needle and rotation speed. These parameters may affect the force at which the needle interacts with the tissue. A reduction in force has been shown to decrease the compression of the prostate and potentially increase the accuracy of seed position. Rotating the needle as it is inserted may reduce frictional forces while increasing accuracy. However, needle rotations are considered to increase tissue damage due to the drilling nature of the insertion. We explore many of the factors involved in optimizing a brachytherapy robot, and the potential effects each parameter may have on the procedure. We also investigate the interaction of rotating needles in gel and suggest the rotate-cannula-only method of conical needle insertion to minimize any tissue damage while still maintaining the benefits of reduced force and increased accuracy.

  13. Computerized Planning of Prostate Cryosurgery Using Variable Cryoprobe Insertion Depth

    PubMed Central

    Rossi, Michael R.; Tanaka, Daigo; Shimada, Kenji; Rabin, Yoed

    2010-01-01

    The current study presents a computerized planning scheme for prostate cryosurgery using a variable insertion-depth strategy. This study is a part of an ongoing effort to develop computerized tools for cryosurgery. Based on typical clinical practices, previous automated planning schemes have required that all cryoprobes be aligned at a single insertion depth. The current study investigates the benefit of removing this constraint, in comparison with results based on uniform insertion-depth planning as well as the so-called “pullback procedure”. Planning is based on the so-called “bubble-packing method”, and its quality is evaluated with bioheat transfer simulations. This study is based on five 3D prostate models, reconstructed from ultrasound imaging, and cryoprobe active length in the range of 15 mm to 35 mm. The variable insertion depth technique is found to consistently provide superior results when compared to the other placement methods. Furthermore, it is shown that both the optimal active length and the optimal number of cryoprobes vary among prostate models, based on the size and shape of the target region. Due to its low computational cost, the new scheme can be used to determine the optimal cryoprobe layout for a given prostate model in real time. PMID:19111714

  14. Temperature induced compositional redistribution in blended insertion electrodes

    NASA Astrophysics Data System (ADS)

    Heubner, C.; Lämmel, C.; Schneider, M.; Michaelis, A.

    2017-03-01

    Blending insertion compounds is a novel and promising approach to design advanced electrodes for future lithium-ion batteries. In spite of the considerable improvements regarding safety issues and power density, the understanding of basic interactions between the constituents of the blend and differences towards common single compound insertion electrodes is still ongoing. Herein we explore and verify the effect of temperature induced compositional redistribution of lithium-ions between the constituents of a blended insertion electrode for the first time. A model-like blend electrode and a special experimental setup is used to measure the compositional redistribution current between the constituents when subjected to a temperature change. The amount of lithium exchanged between the constituents of the blend is also derived theoretically based on the thermodynamic properties of the pure constituents, showing excellent agreement to the experimental results. Theoretical and experimental results proof that significant amounts of lithium are exchanged between the constituents without any cycling of the battery, suggesting that this effect may intrinsically reduce the cycle life of batteries with blended insertion electrodes.

  15. Thirsk inserts samples into MELFI in the JPM

    NASA Image and Video Library

    2009-06-07

    ISS020-E-007156 (7 June 2009) --- Canadian Space Agency astronaut Robert Thirsk, Expedition 20 flight engineer, performs an insertion of urine samples into the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) study in the Japanese Kibo laboratory of the International Space Station.

  16. Nutrition and Repository: Insertion of Urine Sample into MELFI

    NASA Image and Video Library

    2009-04-18

    ISS019-E-010165 (18 April 2009) --- Astronaut Michael Barratt, Expedition 19/20 flight engineer, performs an insertion of urine samples into the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) study in the Japanese Kibo laboratory of the International Space Station.

  17. Nutrition and Repository: Insertion of Urine Sample into MELFI

    NASA Image and Video Library

    2009-04-18

    ISS019-E-010170 (18 April 2009) --- Astronaut Michael Barratt, Expedition 19/20 flight engineer, performs an insertion of urine samples into the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) study in the Japanese Kibo laboratory of the International Space Station.

  18. Coleman prepares to insert samples into the MELFI

    NASA Image and Video Library

    2010-12-27

    ISS026-E-023768 (27 Dec. 2010) --- NASA astronaut Catherine (Cady) Coleman, Expedition 26 flight engineer, prepares to insert samples into the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) study in the Japanese Kibo laboratory of the International Space Station.

  19. Root cause of incomplete control rod insertions at Westinghouse reactors

    SciTech Connect

    Ray, S.

    1997-01-01

    Within the past year, incomplete RCCA insertions have been observed on high burnup fuel assemblies at two Westinghouse PWRs. Initial tests at the Wolf Creek site indicated that the direct cause of the incomplete insertions observed at Wolf Creek was excessive fuel assembly thimble tube distortion. Westinghouse committed to the NRC to perform a root cause analysis by the end of August, 1996. The root cause analysis process used by Westinghouse included testing at ten sites to obtain drag, growth and other characteristics of high burnup fuel assemblies. It also included testing at the Westinghouse hot cell of two of the Wolf Creek incomplete insertion assemblies. A mechanical model was developed to calculate the response of fuel assemblies when subjected to compressive loads. Detailed manufacturing reviews were conducted to determine if this was a manufacturing related issue. In addition, a review of available worldwide experience was performed. Based on the above, it was concluded that the thimble tube distortion observed on the Wolf Creek incomplete insertion assemblies was caused by unusual fuel assembly growth over and above what would typically be expected as a result of irradiation exposure. It was determined that the unusual growth component is a combination of growth due to oxide accumulation and accelerated growth, and would only be expected in high temperature plants on fuel assemblies that see long residence times and high power duties.

  20. Effects of lithium insertion on thermal conductivity of silicon nanowires

    SciTech Connect

    Xu, Wen; Zhang, Gang; Li, Baowen

    2015-04-27

    Recently, silicon nanowires (SiNWs) have been applied as high-performance Li battery anodes, since they can overcome the pulverization and mechanical fracture during lithiation. Although thermal stability is one of the most important parameters that determine safety of Li batteries, thermal conductivity of SiNWs with Li insertion remains unclear. In this letter, using molecular dynamics simulations, we study room temperature thermal conductivity of SiNWs with Li insertion. It is found that compared with the pristine SiNW, there is as much as 60% reduction in thermal conductivity with 10% concentration of inserted Li atoms, while under the same impurity concentration the reduction in thermal conductivity of the mass-disordered SiNW is only 30%. With lattice dynamics calculations and normal mode decomposition, it is revealed that the phonon lifetimes in SiNWs decrease greatly due to strong scattering of phonons by vibrational modes of Li atoms, especially for those high frequency phonons. The observed strong phonon scattering phenomenon in Li-inserted SiNWs is similar to the phonon rattling effect. Our study serves as an exploration of thermal properties of SiNWs as Li battery anodes or weakly coupled with impurity atoms.

  1. Interaural Attenuation of a Click Stimulus Using Deep and Shallow Placement of an Insert Earphone.

    PubMed

    Laws, D W; Roller, S M; Perry, C K

    1993-11-01

    The effect of deep versus shallow insertion of the ER-3A insert earphone on interaural attenuation (IA) of a click stimulus was examined. IA values for five subjects with profound unilateral hearing loss were obtained. The results (a mean IA difference of 2 dB between the two insertion depths) indicated that IAs for deep insertion were not significantly different from IAs for shallow insertion. Thus deep insertion of insert earphones to achieve larger IA values was not recommended for click stimuli.

  2. Cochlear implant insertion forces in microdissected human cochlea to evaluate a prototype array.

    PubMed

    Nguyen, Yann; Miroir, Mathieu; Kazmitcheff, Guillaume; Sutter, Jasmine; Bensidhoum, Morad; Ferrary, Evelyne; Sterkers, Olivier; Bozorg Grayeli, Alexis

    2012-01-01

    Cochlear implant array insertion forces are potentially related to cochlear trauma. We compared these forces between a standard (Digisonic SP; Neurelec, Vallauris, France) and an array prototype (Neurelec) with a smaller diameter. The arrays were inserted by a mechatronic tool in 23 dissected human cochlea specimens exposing the basilar membrane. The array progression under the basilar membrane was filmed together with dynamic force measurements. Insertion force profiles and depth of insertion were compared. The recordings showed lower insertion forces beyond 270° of insertion and deeper insertions with the thin prototype array. This will potentially allow larger cochlear coverage with less trauma.

  3. [Discussion on different methods of painless needle insertion based on positions].

    PubMed

    Chen, Chao; Shi, Xuemin

    2016-03-01

    Based on multiple painless needle insertion skills in clinic combined with own experience, the authors propose the opinion that different painless needle insertion methods need to be used according to the positions where acupoints are. The appropriate needle insertion mean must be selected in accord with the anatomical characteristic of acupoint position, namely, tapping insertion is applied in scalp part, skin-pinching up needle insertion is used in forehead and superficial nerve trunk, fingernail-pressure needle insertion in ocular region and positions where large blood vessels distribute, flying acupuncture insertion in face and finger tip, vibrating needle in occipitonuchal region, quivering insertion in abdomen, quick pricking by single hand in the four limbs and back, and chop acupuncture in palm and pelma. The insertion methods are systematically discussed in terms of preparation, acupoint position, manipulation and attention, etc, so that to provide the reference for painless needle insertion.

  4. Efficient simulation of chemical potentials and phase equilibria in associating fluids: monomer/dimer insertion versus gradual particle insertion in primitive water models

    NASA Astrophysics Data System (ADS)

    Vörtler, Horst L.; Kettler, Matthias

    Widom's test particle method for simulation of chemical potentials fails for associating (network forming) fluids. Therefore we study more sophisticated insertion methods, such as gradual particle insertion and the recent unbonded particle insertion of Tripathi and Chapman. We model strongly associating fluids by short-ranged primitive models (PMs) due to Nezbeda and co-workers. Recently, we showed that gradual insertion, in principle, is applicable to PM water. Here, we study systematically subcritical chemical potential isotherms, determine vapour-liquid coexistence densities and estimate the critical point density and temperature. For comparison we implement two variants of the Tripathi-Chapman algorithm. In the first case we use as unbonded test particles only particles which remain single molecules (monomers), when inserted and in the second case such test particles which remain as single molecules or form a two-particle cluster with an existing free molecule (monomer/dimer), when inserted. While monomer insertion improves Widom's method slightly, monomer/dimer insertion extends substantially the range of application to the subcritical temperatures studied by gradual insertion. But, for low temperatures monomer/dimer insertion requires extremely long Markov chains and significantly more computer time than gradual insertion. The Tripathi-Chapman algorithm - a direct extension of Widom's method - is much simpler than gradual insertion and therefore should be preferred at supercritical and critical conditions.

  5. Structures of a DNA Polymerase Inserting Therapeutic Nucleotide Analogues.

    PubMed

    Schaich, Matthew A; Smith, Mallory R; Cloud, Ashley S; Holloran, Sean M; Freudenthal, Bret D

    2017-09-01

    Members of the nucleoside analogue class of cancer therapeutics compete with canonical nucleotides to disrupt numerous cellular processes, including nucleotide homeostasis, DNA and RNA synthesis, and nucleotide metabolism. Nucleoside analogues are triphosphorylated and subsequently inserted into genomic DNA, contributing to the efficacy of therapeutic nucleosides in multiple ways. In some cases, the altered base acts as a mutagen, altering the DNA sequence to promote cellular death; in others, insertion of the altered nucleotide triggers DNA repair pathways, which produce lethal levels of cytotoxic intermediates such as single and double stranded DNA breaks. As a prerequisite to many of these biological outcomes, the modified nucleotide must be accommodated in the DNA polymerase active site during nucleotide insertion. Currently, the molecular contacts that mediate DNA polymerase insertion of modified nucleotides remain unknown for multiple therapeutic compounds, despite decades of clinical use. To determine how modified bases are inserted into duplex DNA, we used mammalian DNA polymerase β (pol β) to visualize the structural conformations of four therapeutically relevant modified nucleotides, 6-thio-2'-deoxyguanosine-5'-triphosphate (6-TdGTP), 5-fluoro-2'-deoxyuridine-5'-triphosphate (5-FdUTP), 5-formyl-deoxycytosine-5'-triphosphate (5-FodCTP), and 5-formyl-deoxyuridine-5'-triphosphate (5-FodUTP). Together, the structures reveal a pattern in which the modified nucleotides utilize Watson-Crick base pairing interactions similar to that of unmodified nucleotides. The nucleotide modifications were consistently positioned in the major groove of duplex DNA, accommodated by an open cavity in pol β. These results provide novel information for the rational design of new therapeutic nucleoside analogues and a greater understanding of how modified nucleotides are tolerated by polymerases.

  6. Customizable engineered blood vessels using 3D printed inserts.

    PubMed

    Pinnock, Cameron B; Meier, Elizabeth M; Joshi, Neeraj N; Wu, Bin; Lam, Mai T

    2016-04-15

    Current techniques for tissue engineering blood vessels are not customizable for vascular size variation and vessel wall thickness. These critical parameters vary widely between the different arteries in the human body, and the ability to engineer vessels of varying sizes could increase capabilities for disease modeling and treatment options. We present an innovative method for producing customizable, tissue engineered, self-organizing vascular constructs by replicating a major structural component of blood vessels - the smooth muscle layer, or tunica media. We utilize a unique system combining 3D printed plate inserts to control construct size and shape, and cell sheets supported by a temporary fibrin hydrogel to encourage cellular self-organization into a tubular form resembling a natural artery. To form the vascular construct, 3D printed inserts are adhered to tissue culture plates, fibrin hydrogel is deposited around the inserts, and human aortic smooth muscle cells are then seeded atop the fibrin hydrogel. The gel, aided by the innate contractile properties of the smooth muscle cells, aggregates towards the center post insert, creating a tissue ring of smooth muscle cells. These rings are then stacked into the final tubular construct. Our methodology is robust, easily repeatable and allows for customization of cellular composition, vessel wall thickness, and length of the vessel construct merely by varying the size of the 3D printed inserts. This platform has potential for facilitating more accurate modeling of vascular pathology, serving as a drug discovery tool, or for vessel repair in disease treatment. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Effectiveness of various drugs in controlling bleeding after IUD insertion.

    PubMed

    Ali, R K; Satterthwaite, A P

    1968-01-01

    The National Research Institute of Family Planning of Pakistan in April 1967 initiated a study to determine what drugs and other variables might aid in reducing IUD postinsertion bleeding. 768 women were admitted to the study after the insertion of a polyethylene plastic Lippes loop. Each woman was given 1 of the following medications (double-blind test) in a packet: 1) Vitamin-K (10 mg tid for 21 days), 2) Vitamin-C (50 mg tid for 21 days), 3) ferrous sulfate (.3 mg tid for 21 days), 4) Lyndiol (2.5 mg daily for 21 days), and 5) placebo (glucose-filled gelatin capsules, 1 daily for 21 days). 623 (81%) of the patients returned for the first-month follow-up. Second- and third-month follow-ups had far fewer returns; data analysis was thus restricted to the first month only. 4% of the loops were removed for bleeding. 91.5% reported some degree of postinsertion bleeding. Bleeding was reported as minimal or spotting and slight bleeding (less than normal menstrual flow), normal menstrual flow, or heavy bleeding and clots (more than normal menstrual flow). More of the young clients (ages 25-29) returned than expected (249 vs. 222.3); fewer of the older clients (ages 40-44) returned than expected (31 vs. 52.7). Ferrous sulfate was most effective in shifting the control pattern of bleeding to a pattern skewed to lesser degrees of bleeding. The least bleeding was reported for insertion 1-3 months postpartum. With regard to the time since the onset of the last menstrual period, insertion during lactation amenorrhea gave the best results, and insertion prior to Day 13 was much better than insertion during the last half of the cycle.

  8. Dynamics of Inserts and Simple Attachments in DNA Polymers.

    NASA Astrophysics Data System (ADS)

    Beger, Richard David

    All life subsisting processes like RNA transcription, growth and reproduction are related to melting (separation of) the DNA helix. In this thesis we study the hydrogen bond stretch of the DNA polymers for various inserts and simple attachments. We find a dramatic change in the hydrogen bond stretch as a function of inserts, attachment position and the resonant frequency of the attachment. Our results depends on the input parameters of the force constants, amplitudes, resonant frequencies and long range interactions. Most of these parameters are extracted from experimental data. The resonant frequency of the enzymes are used as a free parameter to study their effect. The Green's function technique is used to study the dynamics of (TATA)_2 promoter inserts inside of DNA and the dynamics of simple enzyme -like attachments to DNA. The inserts show that there is a greater thermal hydrogen bond motion near these (TATA) _2 promoter boxes. The amount that the open base pair probability (i.e. thermal hydrogen bond stretch) changes is dependent on the base pair sequence outside the promoter insert. A rigid simple attachment destabilized the DNA helix by increasing the thermal hydrogen bond stretch. When the rigid attachment was allowed to extend over 70 base pairs the helix almost melted. The simple attachments were given resonant frequencies and the effects of such frequencies on the stability of the DNA was probed. Some frequencies destabilized the helix near the attachment sites and showed effects associated with enzyme enhancers. Some frequencies stabilized the helix near the attachment and behaved like enzyme repressors. Finally the attachments were allowed to bond to the Watson-Crick hydrogen atoms. The hydrogen bonds force constants for the Watson-Crick hydrogen bond atoms were therefore lowered. This produced a state of destabilization that increased as the Watson-Crick hydrogen bond force constant decreased. These effects were also resonant frequency dependent.

  9. Choice of Tevatron tune with matched low-. beta. insertions

    SciTech Connect

    Month, M.

    1984-06-20

    The Tevatron lattice, following closely the Main Ring lattice, is made up of approximately 90 FODO cells with six straight sections equally spaced. The straight sections are identical (neglecting the special high-..beta.. straight section used for resonant extraction) providing six-fold symmetry. Each straight section is comprised mainly of a pair of doublets, one at each end, in an antisymmetric configuration. The ..beta..-functions are matched to the building block cells but the dispersion function is not. The ..beta..-function matching implies that the structure is not sensitive to the tune of the sextant (i.e., structure resonances); however, the dispersion mismatch excites off-momentum dipole resonances and the dispersion structure of the ring is therefore sensitive to sextant tunes near an integer. The introduction of low-..beta.. insertions can be accomplished by replacing a standard insertion (expanded somewhat from the doublet pair straight section) with a low-..beta.. insertion. By matching the ends of the replacement units with respect to ..beta..-functions and dispersion function, the full lattice is made insensitive to linear structure resonances. Procedures are described here for introducing into the idealized Tevatron lattice considered here a single matched low-..beta.. insertion at BO, and two matched low-..beta.. insertions at BO and DO. The main consequence is the need for a significant number of independently powered quadrupoles. Another conclusion is related to the choice of tune, where it is found that the arbitrary rule of maintaining a fixed tune for all configurations should be modified.

  10. Effects on Subtalar Joint Stress Distribution After Cannulated Screw Insertion at Different Positions and Directions.

    PubMed

    Yuan, Cheng-song; Chen, Wan; Chen, Chen; Yang, Guang-hua; Hu, Chao; Tang, Kang-lai

    2015-01-01

    We investigated the effects on subtalar joint stress distribution after cannulated screw insertion at different positions and directions. After establishing a 3-dimensional geometric model of a normal subtalar joint, we analyzed the most ideal cannulated screw insertion position and approach for subtalar joint stress distribution and compared the differences in loading stress, antirotary strength, and anti-inversion/eversion strength among lateral-medial antiparallel screw insertion, traditional screw insertion, and ideal cannulated screw insertion. The screw insertion approach allowing the most uniform subtalar joint loading stress distribution was lateral screw insertion near the border of the talar neck plus medial screw insertion close to the ankle joint. For stress distribution uniformity, antirotary strength, and anti-inversion/eversion strength, lateral-medial antiparallel screw insertion was superior to traditional double-screw insertion. Compared with ideal cannulated screw insertion, slightly poorer stress distribution uniformity and better antirotary strength and anti-inversion/eversion strength were observed for lateral-medial antiparallel screw insertion. Traditional single-screw insertion was better than double-screw insertion for stress distribution uniformity but worse for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion was slightly worse for stress distribution uniformity than was ideal cannulated screw insertion but superior to traditional screw insertion. It was better than both ideal cannulated screw insertion and traditional screw insertion for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion is an approach with simple localization, convenient operation, and good safety.

  11. Effects of rotated square inserts on the longitudinal vibration band gaps in thin phononic crystal plates

    NASA Astrophysics Data System (ADS)

    Zhao, Haojiang; Liu, Rongqiang; Shi, Chuang; Guo, Hongwei; Deng, Zongquan

    2015-07-01

    Longitudinal vibration of thin phononic crystal plates with a hybrid square-like array of square inserts is investigated. The plane wave expansion method is used to calculate the vibration band structure of the plate. Numerical results show that rotated square inserts can open several vibration gaps, and the band structures are twisted because of the rotation of inserts. Filling fraction and material of the insert affect the change law of the gap width versus the rotation angles of square inserts.

  12. Controlling the electronic and geometric structures of 2D insertions to realize high performance metal/insertion-MoS2 sandwich interfaces.

    PubMed

    Su, Jie; Feng, Liping; Zeng, Wei; Liu, Zhengtang

    2017-06-08

    Metal/insertion-MoS2 sandwich interfaces are designed to reduce the Schottky barriers at metal-MoS2 interfaces. The effects of geometric and electronic structures of two-dimensional (2D) insertion materials on the contact properties of metal/insertion-MoS2 interfaces are comparatively studied by first-principles calculations. Regardless of the geometric and electronic structures of 2D insertion materials, Fermi level pinning effects and charge scattering at the metal/insertion-MoS2 interface are weakened due to weak interactions between the insertion and MoS2 layers, no gap states and negligible structural deformations for MoS2 layers. The Schottky barriers at metal/insertion-MoS2 interfaces are induced by three interface dipoles and four potential steps that are determined by the charge transfers and structural deformations of 2D insertion materials. The lower the electron affinities of 2D insertion materials, the more are the electrons lost from the Sc surface, resulting in lower n-type Schottky barriers at Sc/insertion-MoS2 interfaces. The larger the ionization potentials and the thinner the thicknesses of 2D insertion materials, the fewer are the electrons that accumulate at the Pt surface, leading to lower p-type Schottky barriers at Pt/insertion-MoS2 interfaces. All Sc/insertion-MoS2 interfaces exhibited ohmic characters. The Pt/BN-MoS2 interface exhibits the lowest p-type Schottky barrier of 0.52 eV due to the largest ionization potential (∼6.88 eV) and the thinnest thickness (single atomic layer thickness) of BN. These results in this work are beneficial to understand and design high performance metal/insertion-MoS2 interfaces through 2D insertion materials.

  13. Lesion insertion in the projection domain: Methods and initial results

    SciTech Connect

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia

    2015-12-15

    Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically

  14. Commissioning of the upgraded ATLAS Pixel Detector for Run2 at LHC

    NASA Astrophysics Data System (ADS)

    Dobos, Daniel

    2016-07-01

    The Pixel Detector of the ATLAS experiment has shown excellent performance during the whole Run-1 of LHC. Taking advantage of the long showdown, the detector was extracted from the experiment and brought to the surface, to equip it with new service quarter panels, to repair modules and to ease installation of the Insertable B-Layer, a fourth layer of pixel detectors, installed in May 2014 between the existing Pixel Detector and a new smaller radius beam-pipe at a radius of 3.3 cm. To cope with the high radiation and pixel occupancy due to the proximity to the interaction point, a new read-out chip and two different silicon sensor technologies (planar and 3D) have been developed. An overview of the refurbishing of the Pixel Detector and of the IBL project as well as early performance tests using cosmic rays and beam data will be presented.

  15. Method of installing a metallic threaded insert in a composite/rubber panel

    NASA Astrophysics Data System (ADS)

    Izdebski, Stanley

    1994-02-01

    A method of installing a metallic threaded insert in a composite/rubber panel consists of threading a first insert section into a preformed hole in a fiberglass composite panel and bonding a rubber panel over the fiberglass composite panel. The rubber panel includes an opening which is positioned over the first insert section. A second insert section is threaded onto an elongated positioning bolt and then the positioning bolt is threaded into the first insert section. The second insert section is threaded downwardly on the positioning so as to be in adjacent relation to the first insert section, and the opening in the rubber panel is filled with a rubber compound. The rubber compound is cured, preferably at room temperature, to set the second insert section in position and the positioning bolt is threaded out of the first and second insert sections.

  16. Insertion devices for the Advanced Light Source at LBL

    SciTech Connect

    Hassenzahl, W.; Chin, J.; Halbach, K.; Hoyer, E.; Humphries, D.; Kincaid, B.; Savoy, R.

    1989-03-01

    The Advanced Light Source (ALS) at the Lawrence Berkeley Laboratory will be the first of the new generation of dedicated synchrotron light sources to be put into operation. Specially designed insertion devices will be required to realize the high brightness photon beams made possible by the low emittance of the electron beam. The complement of insertion devices on the ALS will include undulators with periods as short as 3.9 cm and one or more high field wigglers. The first device to be designed is a 5 m long, 5 cm period, hybrid undulator. The goal of very high brightness and high harmonic output imposes unusually tight tolerances on the magnetic field quality and thus on the mechanical structure. The design process, using a generic structure for all undulators, is described. 5 refs., 4 figs., 1 tab.

  17. Needle insertion with duty-cycled rotation into multiple media.

    PubMed

    Lehocky, Craig A; Riviere, Cameron N

    2012-01-01

    Thin, flexible needles can be steered along nonlinear paths to reach deep anatomical structures within the human body. This study builds upon previous work involving steering of bevel-tipped needles by inserting while rotating in a duty-cycled fashion. Here we investigate how needle material and radius, duty cycle, and tissue stiffness affect needle curvature. Needles were inserted into media while rotated at a specified duty cycle and the curvature was measured. A linear relationship between duty cycle and curvature was observed across all needle materials and radii, and tissue stiffnesses. Following these observations, we developed a model that encapsulates needle and tissue parameters in order to predict the duty cycle needed to achieve a desired curvature.

  18. Chromaticity and low-β insertions in particle colliders

    NASA Astrophysics Data System (ADS)

    Autin, Bruno

    1990-12-01

    Besides its energy range, the main characteristic of a particle collider is its luminosity. A very important piece of equipment to achieve high luminosities is a low-β insertion, a device which focuses the beam down to a tiny spot size. The focusing limits are not only technological, they are also associated with the aberrations of such systems. This paper deals with the chromatic aberrations. In a first part, the treatment of the focusing errors is reviewed and a formalism using symbolic computation is set up so that high-order perturbations can be evaluated, although results are limited to the second-order betatron tune shift and to its interpretation. In a second part, a completely analytical theory of the final doublet of a low-β insertion is given for a special model of flat-beam focusing.

  19. Wear mechanisms of milling inserts: Dry and wet cutting

    SciTech Connect

    Gu, J.; Tung, S.C.; Barber, G.C.

    1998-07-01

    There is less literature on wear of milling tools than on wear of turning tools because milling is one of the most complicated machining operations. The intermittent milling action creates mechanical and thermal surges that distinguish milling from single-point machining. A systematic tool life study for face milling inserts was conducted with and without coolant. Workpieces made of 4140 steel were cut by C5 grade carbide inserts under various cutting conditions. The comparison between dry and wet cutting shows that caution should be taken when applying a coolant for milling operations. Special tests should be carried out in evaluating potential coolant candidates. It is not always true that coolant enhances tool life for milling. Wear mechanisms are presented by means of war maps. Identified wear mechanisms are: micro-attrition, micro-abrasion, mechanical fatigue, thermal fatigue, thermal pitting, and edge chipping.

  20. Insertion sequences enrichment in extreme Red sea brine pool vent.

    PubMed

    Elbehery, Ali H A; Aziz, Ramy K; Siam, Rania

    2017-03-01

    Mobile genetic elements are major agents of genome diversification and evolution. Limited studies addressed their characteristics, including abundance, and role in extreme habitats. One of the rare natural habitats exposed to multiple-extreme conditions, including high temperature, salinity and concentration of heavy metals, are the Red Sea brine pools. We assessed the abundance and distribution of different mobile genetic elements in four Red Sea brine pools including the world's largest known multiple-extreme deep-sea environment, the Red Sea Atlantis II Deep. We report a gradient in the abundance of mobile genetic elements, dramatically increasing in the harshest environment of the pool. Additionally, we identified a strong association between the abundance of insertion sequences and extreme conditions, being highest in the harshest and deepest layer of the Red Sea Atlantis II Deep. Our comparative analyses of mobile genetic elements in secluded, extreme and relatively non-extreme environments, suggest that insertion sequences predominantly contribute to polyextremophiles genome plasticity.

  1. The Ziegler—Natta olefin insertion reaction for cationic metals

    NASA Astrophysics Data System (ADS)

    Jensen, Vidar R.; Siegban, Per E. M.

    1993-09-01

    The catalytic Ziegler—Natta polymerization reaction has been studied for a set of metal cations, in order to identify the role of the positive charge on this process. Geometry optimizations have been performed for the reactant metal—methyl systems, the π-coordinated olefin systems, the transition states for the olefin insertion and finally for the product metal—propyl systems. All valence electrons are correlated. The cations selected for this study are the transition metals Zr + and Ti +, the non-transition metals Be +, Mg +, Al + and finally also Si +. The transition metal cations are found to have very low barriers for the insertion, but the lowest barrier is actually found for Be +. The results are discussed in terms of the ionization energies and the accessibility to valence p and d orbitals. Comparisons are made to previous theoretical work on cationic model systems.

  2. Massive reflux and aspiration after radiographically inserted gastrostomy tube placement.

    PubMed

    Chesoni, Sandra A; Bach, John R; Okamura, Erica Mia

    2015-01-01

    To the authors' knowledge, fatal postgastrostomy aspiration within 2 days of enteral nutrition has not been reported. The authors report consecutive cases of severe postgastrotomy aspiration with one being fatal for a 26-yr-old with Duchenne muscular dystrophy 2 days after initiation of gastrostomy feedings. Previous to these consecutive radiographically inserted gastrostomies, all gastrotomies at the institution were percutaneous endoscopic gastrostomies or open gastrostomies. Radiographically inserted gastrostomy tubes have an increased likelihood of being oriented toward the esophagus as opposed to the duodenum, which may increase the risk for reflux. Elimination of invasive airway tubes should be delayed until after gastrostomy feedings are documented to be well tolerated. Oximetry and repeated measurements of vital capacity can suggest changes in the status of airway clearance.

  3. Calculation of magnetic error fields in hybrid insertion devices

    NASA Astrophysics Data System (ADS)

    Savoy, R.; Halbach, K.; Hassenzahl, W.; Hoyer, E.; Humphries, D.; Kincaid, B.

    1990-05-01

    The Advanced Light Source (ALS) at the Lawrence Berkeley Laboratory requires insertion devices with fields sufficiently accurate to take advantage of the small emittance of the ALS electron beam. To maintain the spectral performance of the synchrotron radiation and to limit steering effects on the electron beam these errors must be smaller than 0.25%. This paper develops a procedure for calculating the steering error due to misalignment of the easy axis of the permanent-magnet material. The procedure is based on a three-dimensional theory of the design of hybrid insertion devices developed by one of us. The acceptable tolerance for easy axis misalignment is found for a 5-cm-period undulator proposed for the ALS.

  4. Practical points on transvenous insertion of inferior vena cava filters.

    PubMed

    Novelline, R A

    1980-01-01

    During the transvenous insertion of Kimray-Greenfield (KG) and Mobin-Uddin (MU) inferior vena cava filters at the Massachusetts General Hospital, several problems have been encountered and successfully resolved. The author offers suggestions for dealing with small or spastic internal jugular veins, prominent eustachian valves (valves of the inferior vena cava), congenital variations in the inferior vena cava, inferior vena cava thrombi, and filters that have been placed too low or too high. In addition, methods are described for directing the KG filter with gravity, identifying the lowest renal vein with a selective catheter, inserting the KG filter from a femoral venous route, assuring proper seating of an MU filter, and confirming filter position following placement.

  5. Convective heat transfer enhancement inside tubes using inserted helical coils

    NASA Astrophysics Data System (ADS)

    Ali, R. K.; Sharafeldeen, M. A.; Berbish, N. S.; Moawed, M. A.

    2016-01-01

    Convective heat transfer was experimentally investigated in tubes with helical coils inserts in turbulent flow regime within Reynolds number range of 14400 ≤ Re ≤ 42900. The present work aims to extend the experimental data available on wire coil inserts to cover wire diameter ratio from 0.044 to 0.133 and coil pitch ratio from 1 to 5. Uniform heat flux was applied to the external surface of the tube and air was selected as fluid. The effects of Reynolds number and wire diameter and coil pitch ratios on the Nusselt number and friction factor were studied. The enhancement efficiency and performance criteria ranges are of (46.9-82.6%) and (100.1-128%) within the investigated range of the different parameters, respectively. Correlations are obtained for the average Nusselt number and friction factor utilizing the present measurements within the investigated range of geometrical parameters and Re.

  6. Osmotic force resisting chain insertion in a colloidal suspension

    NASA Astrophysics Data System (ADS)

    Castelnovo, M.; Bowles, R. K.; Reiss, H.; Gelbart, W. M.

    2003-02-01

    We consider the problem of inserting a stiff chain into a colloidal suspension of particles that interact with it through excluded volume forces. The free energy of insertion is associated with the work of creating a cavity devoid of colloid and sufficiently large to accommodate the chain. The corresponding work per unit length is the force that resists the entry of the chain into the colloidal suspension. In the case of a hard sphere fluid, this work can be calculated straightforwardly within the scaled particle theory; for solutions of flexible polymers, on the other hand, we employ simple scaling arguments. The forces computed in these ways are shown, for nanometer chain and colloid diameters, to be of the order of tens of pN for solution volume fractions of a few tenths. These magnitudes are argued to be important for biophysical processes such as the ejection of DNA from viral capsids into the cell cytoplasm.

  7. Destabilization of the human epigenome: consequences of foreign DNA insertions.

    PubMed

    Weber, Stefanie; Hofmann, Andrea; Herms, Stefan; Hoffmann, Per; Doerfler, Walter

    2015-08-01

    We previously reported changes of DNA methylation and transcription patterns in mammalian cells that carry integrated foreign DNA. Experiments were now designed to assess the epigenetic consequences of inserting a 5.6 kbp plasmid into the human genome. Differential transcription and CpG methylation patterns were compared between transgenomic and nontransgenomic cell clones by using gene chip microarray systems. In 4.7% of the 28.869 gene segments analyzed, transcriptional activities were up- or downregulated in the transgenomic cell clones. Genome-wide profiling revealed differential methylation in 3791 of > 480,000 CpG's examined in transgenomic versus nontransgenomic clones. The data document genome-wide effects of foreign DNA insertions on the epigenetic stability of human cells. Many fields in experimental biology and medicine employ transgenomic or otherwise genome-manipulated cells or organisms without considering the epigenetic consequences for the recipient genomes.

  8. Utility of collecting blood cultures through newly inserted intravenous catheters.

    PubMed

    Isaacman, D J; Karasic, R B

    1990-11-01

    We prospectively examined the utility of obtaining blood cultures through newly inserted intravenous catheters in 99 children who required both a blood culture and placement of an intravenous catheter. Two blood cultures were collected from each patient, one through a freshly inserted intravenous catheter and another through a butterfly needle at a separate venipuncture site. A standardized technique of skin preparation with povidone-iodine was used. The rate of contamination was 1.0% (95% confidence intervals, 0 to 3.0%) for each method. Ten patients had blood cultures yielding true pathogens; in five of these bacteremic children, only one of two sets of blood cultures was positive. We conclude that blood cultures can be collected through freshly placed intravenous catheters without increasing the risk of contamination. These results also raise the possibility that obtaining two blood cultures instead of a single culture may improve the detection of bacteremia in children.

  9. Flexibility in targeting and insertion during bacterial membrane protein biogenesis

    SciTech Connect

    Bloois, Edwin van; Hagen-Jongman, Corinne M. ten; Luirink, Joen

    2007-10-26

    The biogenesis of Escherichia coli inner membrane proteins (IMPs) is assisted by targeting and insertion factors such as the signal recognition particle (SRP), the Sec-translocon and YidC with translocation of (large) periplasmic domains energized by SecA and the proton motive force (pmf). The use of these factors and forces is probably primarily determined by specific structural features of an IMP. To analyze these features we have engineered a set of model IMPs based on endogenous E. coli IMPs known to follow distinct targeting and insertion pathways. The modified model IMPs were analyzed for altered routing using an in vivo protease mapping approach. The data suggest a facultative use of different combinations of factors.

  10. Percutaneous ultrasound-guided insertion of ventriculo-atrial shunts.

    PubMed

    McCracken, James Albert; Bahl, Anuj; McMullan, John

    2016-08-01

    Ventriculo-atrial (VA) shunts have been in use for >60 years but less frequently so of late. This is due to a combination of the risk of cardiac complications, lack of expertise and a lengthy operation. We present our consecutive prospective series of 10 VA shunts inserted using a percutaneous method employing the Sonowand Invite™ neuronavigation system for both the distal and proximal catheters, over a 13-month period. We had two complications of cases needing revision, but our series highlights a safe and reproducible method of inserting a VA shunt. About 30% of the procedures were carried out by a trainee as the primary surgeon. This technique does not necessarily require the expertise of a complex hydrocephalus surgeon and is thus able to be in the armoury of any neurosurgeon needing to do a VA shunt procedure. The indications, operative data and outcomes of our patients are discussed.

  11. Auditory behavioral thresholds for Japanese macaques using insert earphones.

    PubMed

    Smith, D W; Olszyk, V B

    1997-01-01

    The goal of this study was to measure behavioral auditory thresholds in four Japanese macaques. Animals were trained using food as a reward in an operant reinforcement paradigm. Stimuli were 1-s sinusoids with 10-ms rise/fall times delivered through insert earphones (Etymotic ER-1) having expandable foam eartips. The animals generally produced threshold contours similar in shape to those reported for other macaques species, except that the low-frequency thresholds may have been slightly higher in the present studies. At middle and high frequencies, thresholds fell at the lower extreme of the range previously reported in other macaque species. The possible difference in low-frequency thresholds may have been a result of either transducer and calibration differences between studies or true species variations, or both. Though somewhat limited at high frequencies, the insert earphones used in these studies offer more reliable calibrations, less susceptibility to changes in positioning with movement of the animal, and greater interaural attenuation.

  12. Metallocene Catalytic Insertion Polymerization of 1-Silene to Polycarbosilanes

    PubMed Central

    Tian, Yuelong; Ge, Min; Zhang, Weigang; Lv, Xiaoxu; Yu, Shouquan

    2015-01-01

    Metallocene of zirconium were used as a catalyst for an insertion polymerization of 1-methylsilene directly into pre-ceramic precursor polyzirconocenecarbosilane (PZCS) during dechlorination of dichlorodimethylesilane by sodium, which exhibits high catalytic effectiveness with the maximum conversion ratio of polycarbosilane up to 91%. The average molecular weights of polymers synthesized are less than 1400, all with very narrow polymolecularities. The mechanism of catalytic polymerization was assumed to be similar to a coordination insertion polymerization of 1-olefins by metallocenes. The obtained PZCS show high ceramic yields with formation of composite ceramics of ZrC-SiC, which are novel polymeric precursors of ultra-high temperature ceramic (UHTC) fiber and composite. PMID:26541636

  13. Phase transitions in insertion electrodes for lithium batteries

    SciTech Connect

    Thackeray, M. M.

    2000-02-02

    Phase transitions that occur during lithium insertion into layered and framework structures are discussed in the context of their application as positive and negative electrodes in lithium-ion batteries. The discussion is focused on the two-dimensional structures of graphite, LiNi{sub 1{minus}x}M{sub x}O{sub 2} (M = Co, Ti and Mg), and Li{sub 1.2}V{sub 3}O{sub 8}; examples of framework structures with a three-dimensional interstitial space for Li{sup +}-ion transport include the spinel oxides and intermetallic compounds with zinc-blende-type structures. The phase transitions are discussed in terms of their tolerance to lithium insertion and extraction and to the chemical stability of the electrodes in the cell environment.

  14. [Neonatology nurses' knowledge about Peripherally Inserted Central Venous Catheter].

    PubMed

    Belo, Marcela Patricia Macêdo; Silva, Roberta Albuquerque Mello de Castro; Nogueira, Isis Larissa Maia; Mizoguti, Daniele Pereira; Ventura, Claudiane Maria Urbano

    2012-01-01

    The Peripherally Inserted Central Catheter (PICC) has been used as a safe venous access for infants at risk. The aim of this study was to describe the knowledge and practice of nurses from the five public Neonatal Intensive Care Units, of Recife-PE, Brazil, about the use of the PICC. The sample was comprised by 52 nurses; data were collected from January to February/2010. It was found that 64,8% of nurses did not have license for insertion of the PICC. Only two units routinely used the PICC. About the indication of the access, the accuracy was above 70%. In unit B only 8,3% of nurses reported adequate initial location of the catheter tip. It was concluded that is necessary greater incentives to train nurses to use the PICC.

  15. [Fracture healing under intramedullary insertion of wires with hydroxyapatite coating].

    PubMed

    Ir'ianov, Iu M; Kir'ianov, N A; Popkov, A V

    2014-01-01

    To study morphological features of the bone formation process in consolidation of fractures of long tubular bones in conditions of intramedullary wires insertion with bioactive calcium-phosphate coating of hydroxyapatite. In experimental study in dogs was simulated open comminuted tibia fracture and performed intramedullary insertion of wires with hydroxyapatite coating. Using light and electron microscopy, using X-ray electron microprobe microanalyses were studied bone regenerates in 14-360 days after surgery. It was found that around wires there is a formation of an area of active reparative bone formation and angiogenesis, bone shaped case with the properties of the conductor and inducer of osteogenesis. Fracture consolidation is carried out in the early stages of the primary type without formation of cartilage and connective tissue in the bone adhesion. Study results testify that intramedullary wires with hydroxyapatite coating positively influence on the process and intensity of reparative bone formation in fracture healing.

  16. Challenges for Insertion of Structural Nanomaterials in Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Sochi, Emilie J.

    2012-01-01

    In the two decades since Iijima's report on carbon nanotubes (CNT), there has been great interest in realizing the benefits of mechanical properties observed at the nanoscale in large-scale structures. The weight savings possible due to dramatic improvements in mechanical properties relative to state-of-the-art material systems can be game changing for applications like aerospace vehicles. While there has been significant progress in commercial production of CNTs, major aerospace applications that take advantage of properties offered by this material have yet to be realized. This paper provides a perspective on the technical challenges and barriers for insertion of CNTs as an emerging material technology in aerospace applications and proposes approaches that may reduce the typical timeframe for technology maturation and insertion into aerospace structures.

  17. Insertional hypermutation in mineral oil-induced plasmacytomas.

    PubMed

    Knittel, Gero; Metzner, Mirjam; Beck-Engeser, Gabriele; Kan, Ada; Ahrends, Tomasz; Eilat, Dan; Huppi, Konrad; Wabl, Matthias

    2014-09-01

    Unless stimulated by a chronic inflammatory agent, such as mineral oil, plasma cell tumors are rare in young BALB/c mice. This raises the questions: What do inflammatory tissues provide to promote mutagenesis? And what is the nature of mutagenesis? We determined that mineral oil-induced plasmacytomas produce large amounts of endogenous retroelements--ecotropic and polytropic murine leukemia virus and intracisternal A particles. Therefore, plasmacytoma formation might occur, in part, by de novo insertion of these retroelements, induced or helped by the inflammation. We recovered up to ten de novo insertions in a single plasmacytoma, mostly in genes with common retroviral integration sites. Additional integrations accompany tumor evolution from a solid tumor through several generations in cell culture. The high frequency of de novo integrations into cancer genes suggests that endogenous retroelements are coresponsible for plasmacytoma formation and progression in BALB/c mice.

  18. Needle Insertion with Duty-Cycled Rotation into Multiple Media

    PubMed Central

    Lehocky, Craig A.; Riviere, Cameron N.

    2012-01-01

    Thin, flexible needles can be steered along nonlinear paths to reach deep anatomical structures within the human body. This study builds upon previous work involving steering of bevel-tipped needles by inserting while rotating in a duty-cycled fashion. Here we investigate how needle material and radius, duty cycle, and tissue stiffness affect needle curvature. Needles were inserted into media while rotated at a specified duty cycle and the curvature was measured. A linear relationship between duty cycle and curvature was observed across all needle materials and radii, and tissue stiffnesses. Following these observations, we developed a model that encapsulates needle and tissue parameters in order to predict the duty cycle needed to achieve a desired curvature. PMID:23366042

  19. Management of subcalcaneal pain and Achilles tendonitis with heel inserts

    PubMed Central

    Maclellan, G. E.; Vyvyan, Barbara

    1981-01-01

    Soft tissue symptoms in the leg due to sporting activity are commonly associated with the force of heel strike. Conventional training shoes compromise between comfort and performance; few models are suitably designed for both considerations. Using a visco-elastic polymer insert the symptoms of heel pain and Achilles tendonitis have been largely or completely abolished in a preliminary study. Imagesp117-ap117-bp117-cp118-a PMID:7272653

  20. Insertion force in manual and robotic corneal suturing.

    PubMed

    Yang, Yang; Xu, Cunliang; Deng, Shijing; Xiao, Jingjing

    2012-03-01

    Due to differences in corneal grafting microsurgery between manual and robotic suturing, new challenges have arisen in testing the insertion force and torque of corneal tissue acting on suturing needles in order to guarantee successful completion of surgical procedures. In order to measure the force during the insertion operation, from the needle entering the cornea through the entry point until the puncturing of the exit point along the circular trajectory, a force measurement system was established, including fresh porcine cornea, a corneal-suturing robot, a circular needle, a micro-forceps manipulator with a force transducer, a computer with a data acquisition board and a medical microscope. The force values in the needle coordinate frames were obtained on the basis of a sensor coordinate frame through D-H coordinate transformation, and an index is proposed here to evaluate the insertion performance. Experiments on both manual and robotic suturing were carried out for comparison. The scale and changes of the needle insertion force were obtained using two different suturing methods. The maximal tangent force in robotic suturing is a little larger than in manual suturing, and the maximal resultant force in robotic suturing is somewhat smaller. Although the difference is not very significant, robotic suturing performs in a more stable way. Moreover, the performance evaluation index M(dmax) (the maximum of square root of the quadratic sum of torque components M(OX) and M(OY)) in robotic suturing is much smaller than that in manual suturing. The force measurement system has been verified to be feasible through experimentation. Compared with conventional manual surgery, robotic suturing has some advantages: more stable suturing, smaller distortion torque and fewer invasions to the corneal tissue, showing that its application in minimally invasive surgery is practical. Copyright © 2011 John Wiley & Sons, Ltd.