A rigid disc for protection of exposed blood vessels during negative pressure wound therapy.
Anesäter, Erik; Borgquist, Ola; Torbrand, Christian; Roupé, K Markus; Ingemansson, Richard; Lindstedt, Sandra; Malmsjö, Malin
2013-02-01
There are increasing reports of serious complications and deaths associated with negative pressure wound therapy (NPWT). Bleeding may occur when NPWT is applied to a wound with exposed blood vessels. Inserting a rigid disc in the wound may protect these structures. The authors examined the effects of rigid discs on wound bed tissue pressure and blood flow through a large blood vessel in the wound bed during NPWT. Wounds were created over the femoral artery in the groin of 8 pigs. Rigid discs were inserted. Wound bed pressures and arterial blood flow were measured during NPWT. Pressure transduction to the wound bed was similar for control wounds and wounds with discs. Blood flow through the femoral artery decreased in control wounds. When a disc was inserted, the blood flow was restored. NPWT causes hypoperfusion in the wound bed tissue, presumably as a result of mechanical deformation. The insertion of a rigid barrier alleviates this effect and restores blood flow.
PROCESS WATER BUILDING, TRA605. CONTROL PANEL SUPPLIES STATUS INDICATORS. CARD ...
PROCESS WATER BUILDING, TRA-605. CONTROL PANEL SUPPLIES STATUS INDICATORS. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION ON ORIGINAL NEGATIVE. INL NEGATIVE NO. 4219. Unknown Photographer, 2/13/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Smeets, Ralf; Kolk, Andreas; Gerressen, Marcus; Driemel, Oliver; Maciejewski, Oliver; Hermanns-Sachweh, Benita; Riediger, Dieter; Stein, Jamal M
2009-01-01
The aim of the present study was to analyze the osteogenic potential of a biphasic calcium composite material (BCC) with a negative surface charge for maxillary sinus floor augmentation. In a 61 year old patient, the BCC material was used in a bilateral sinus floor augmentation procedure. Six months postoperative, a bone sample was taken from the augmented regions before two titanium implants were inserted at each side. We analyzed bone neoformation by histology, bone density by computed tomography, and measured the activity of voltage-activated calcium currents of osteoblasts and surface charge effects. Control orthopantomograms were carried out five months after implant insertion. The BCC was biocompatible and replaced by new mineralized bone after being resorbed completely. The material demonstrated a negative surface charge (negative Zeta potential) which was found to be favorable for bone regeneration and osseointegration of dental implants. PMID:19523239
Tunable thermal expansion in framework materials through redox intercalation
Chen, Jun; Gao, Qilong; Sanson, Andrea; Jiang, Xingxing; Huang, Qingzhen; Carnera, Alberto; Rodriguez, Clara Guglieri; Olivi, Luca; Wang, Lei; Hu, Lei; Lin, Kun; Ren, Yang; Lin, Zheshuai; Wang, Cong; Gu, Lin; Deng, Jinxia; Attfield, J. Paul; Xing, Xianran
2017-01-01
Thermal expansion properties of solids are of fundamental interest and control of thermal expansion is important for practical applications but can be difficult to achieve. Many framework-type materials show negative thermal expansion when internal cages are empty but positive thermal expansion when additional atoms or molecules fill internal voids present. Here we show that redox intercalation offers an effective method to control thermal expansion from positive to zero to negative by insertion of Li ions into the simple negative thermal expansion framework material ScF3, doped with 10% Fe to enable reduction. The small concentration of intercalated Li ions has a strong influence through steric hindrance of transverse fluoride ion vibrations, which directly controls the thermal expansion. Redox intercalation of guest ions is thus likely to be a general and effective method for controlling thermal expansion in the many known framework materials with phonon-driven negative thermal expansion. PMID:28181576
Tunable thermal expansion in framework materials through redox intercalation
NASA Astrophysics Data System (ADS)
Chen, Jun; Gao, Qilong; Sanson, Andrea; Jiang, Xingxing; Huang, Qingzhen; Carnera, Alberto; Rodriguez, Clara Guglieri; Olivi, Luca; Wang, Lei; Hu, Lei; Lin, Kun; Ren, Yang; Lin, Zheshuai; Wang, Cong; Gu, Lin; Deng, Jinxia; Attfield, J. Paul; Xing, Xianran
2017-02-01
Thermal expansion properties of solids are of fundamental interest and control of thermal expansion is important for practical applications but can be difficult to achieve. Many framework-type materials show negative thermal expansion when internal cages are empty but positive thermal expansion when additional atoms or molecules fill internal voids present. Here we show that redox intercalation offers an effective method to control thermal expansion from positive to zero to negative by insertion of Li ions into the simple negative thermal expansion framework material ScF3, doped with 10% Fe to enable reduction. The small concentration of intercalated Li ions has a strong influence through steric hindrance of transverse fluoride ion vibrations, which directly controls the thermal expansion. Redox intercalation of guest ions is thus likely to be a general and effective method for controlling thermal expansion in the many known framework materials with phonon-driven negative thermal expansion.
Tunable thermal expansion in framework materials through redox intercalation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Jun; Gao, Qilong; Sanson, Andrea
Thermal expansion properties of solids are of fundamental interest and control of thermal expansion is important for practical applications but can be difficult to achieve. Many framework type materials show negative thermal expansion when internal cages are empty but positive thermal expansion when additional atoms or molecules fill internal voids present, offering a potential route for control. Here we show that redox intercalation offers an effective method to control thermal expansion from positive to zero to negative by insertion of Li ions into the simple negative thermal expansion framework material ScF 3, doped with 10% Fe to enable reduction. Themore » small concentration of intercalated Li ions has a strong influence through steric hindrance of transverse fluoride ion vibrations, which directly controls the thermal expansion. As a result, redox intercalation of guest ions is thus likely to be a general and effective method for controlling thermal expansion in the many known framework materials with phonon-driven negative thermal expansion.« less
Tunable thermal expansion in framework materials through redox intercalation
Chen, Jun; Gao, Qilong; Sanson, Andrea; ...
2017-02-09
Thermal expansion properties of solids are of fundamental interest and control of thermal expansion is important for practical applications but can be difficult to achieve. Many framework type materials show negative thermal expansion when internal cages are empty but positive thermal expansion when additional atoms or molecules fill internal voids present, offering a potential route for control. Here we show that redox intercalation offers an effective method to control thermal expansion from positive to zero to negative by insertion of Li ions into the simple negative thermal expansion framework material ScF 3, doped with 10% Fe to enable reduction. Themore » small concentration of intercalated Li ions has a strong influence through steric hindrance of transverse fluoride ion vibrations, which directly controls the thermal expansion. As a result, redox intercalation of guest ions is thus likely to be a general and effective method for controlling thermal expansion in the many known framework materials with phonon-driven negative thermal expansion.« less
Effects of Single P-Element Insertions on Bristle Number and Viability in Drosophila Melanogaster
Lyman, R. F.; Lawrence, F.; Nuzhdin, S. V.; Mackay, TFC.
1996-01-01
Single P-element mutagenesis was used to construct 1094 lines with P[lArB] inserts on all three major chromosomes in an isogenic background previously free of P elements. The effects of insertions on bristle number and on viability were assessed by comparison to 392 control lines. The variance and effects of P-element inserts on bristle number and viability were larger than those inferred from spontaneous mutations. The distributions of effects on bristle number were symmetrical and highly leptokurtic, such that a few inserts with large effects caused most of the increase in variance. The distribution of effects on viability were negatively skewed and platykurtic. On average, the effects of P-element insertions on bristle number were partly recessive and on viability were completely recessive. P-element inserts with large effects on bristle number tended to have reduced viability, but the correlation between the absolute value of the effects on bristle number and on viability was not strong. Fifty P-element inserts tagging quantitative trait loci (QTLs) with large effects on bristle number were mapped cytogenetically. Two P-element-induced scabrous alleles and five extramacrochaetae alleles were generated. Single P-element mutagenesis is a powerful method for identifying QTLs at the level of genetic locus. PMID:8722781
Effects of single P-element insertions on bristle number and viability in Drosophila melanogaster.
Lyman, R F; Lawrence, F; Nuzhdin, S V; Mackay, T F
1996-05-01
Single P-element mutagenesis was used to construct 1094 lines with P[lArB] inserts on all three major chromosomes in an isogenic background previously free of P elements. The effects of insertions on bristle number and on viability were assessed by comparison to 392 control lines. The variance and effects of P-element inserts on bristle number and viability were larger than those inferred from spontaneous mutations. The distributions of effects on bristle number were symmetrical and highly leptokurtic, such that a few inserts with large effects caused most of the increase in variance. The distribution of effects on viability were negatively skewed and platykurtic. On average, the effects of P-element insertions on bristle number were partly recessive and on viability were completely recessive. P-element inserts with large effects on bristle number tended to have reduced viability, but the correlation between the absolute value of the effects on bristle number and on viability was not strong. Fifty P-element inserts tagging quantitative trait loci (QTLs) with large effects on bristle number were mapped cytogenetically. Two P-element-induced scabrous alleles and five extramacrochaetae alleles were generated. Single P-element mutagenesis is a powerful method for identifying QTLs at the level of genetic locus.
Reiber, Gayle E; Smith, Douglas G; Wallace, Carolyn; Sullivan, Katrina; Hayes, Shane; Vath, Christy; Maciejewski, Matthew L; Yu, Onchee; Heagerty, Patrick J; LeMaster, Joseph
2002-05-15
Many people with diabetes experience lower-limb ulcers. Footwear has been implicated as a primary cause of foot ulcers, yet research is limited on the efficacy of shoe and insert combinations to prevent reulceration. To determine whether extra-depth and -width therapeutic shoes used with 2 types of inserts reduce reulceration in diabetic individuals with a history of foot ulcer. Randomized clinical trial of 400 diabetes patients with history of foot ulcer in 2 Washington State health care organizations who did not require custom shoes for foot deformity and were enrolled between August 1997 and December 1998 and followed up for 2 years. Data collected at regular intervals documented physical, foot, and diabetes characteristics; footwear use; foot lesions; and ulcers. Participants were randomly assigned to receive 3 pairs of therapeutic shoes and 3 pairs of customized medium-density cork inserts with a neoprene closed-cell cover (n = 121); to receive 3 pairs of therapeutic shoes and 3 pairs of prefabricated, tapered polyurethane inserts with a brushed nylon cover (n = 119); or to wear their usual footwear (controls; n = 160). Foot reulceration, compared among the 3 groups. Two-year cumulative reulceration incidence across the 3 groups was low: 15% in the cork-insert group, 14% in the prefabricated-insert group, and 17% in controls. In the intent-to-treat analysis, patients assigned to therapeutic shoes did not have a significantly lower risk of reulceration compared with controls (risk ratio [RR] for the cork-insert group, 0.88; 95% confidence interval [CI], 0.51-1.52 and RR the for prefabricated-insert group, 0.85; 95% CI, 0.48-1.48). All ulcer episodes in patients assigned to therapeutic shoes and 88% wearing nonstudy shoes occurred in patients with foot insensitivity. This study of persons without severe foot deformity does not provide evidence to support widespread dispensing of therapeutic shoes and inserts to diabetic patients with a history of foot ulcer. Study shoes and custom cork or preformed polyurethane inserts conferred no significant ulcer reduction compared with control footwear. This study suggests that careful attention to foot care by health care professionals may be more important than therapeutic footwear but does not negate the possibility that special footwear is beneficial in persons with diabetes who do not receive such close attention to foot care by their health care providers or in individuals with severe foot deformities.
Knobloch, Johannes K.-M.; Nedelmann, Max; Kiel, Kathrin; Bartscht, Katrin; Horstkotte, Matthias A.; Dobinsky, Sabine; Rohde, Holger; Mack, Dietrich
2003-01-01
Transposon mutagenesis with the Enterococcus faecalis transposon Tn917 is a genetic approach frequently used to identify genes related with specific phenotypes in gram-positive bacteria. We established an arbitrary PCR for the rapid and easy identification of Tn917 insertion sites in Staphylococcus epidermidis with six independent, well-characterized biofilm-negative Tn917 transposon mutants, which were clustered in the icaADBC gene locus or harbor Tn917 in the regulatory gene rsbU. For all six of these mutants, short chromosomal DNA fragments flanking both transposon ends could be amplified. All fragments were sufficient to correctly identify the Tn917 insertion sites in the published S. epidermidis genomes. By using this technique, the Tn917 insertion sites of three not-yet-characterized biofilm-negative or nonmucoid mutants were identified. In the biofilm-negative and nonmucoid mutant M12, Tn917 is inserted into a gene homologous to the regulatory gene purR of Bacillus subtilis and Staphylococcus aureus. The Tn917 insertions of the nonmucoid but biofilm-positive mutants M16 and M20 are located in genes homologous to components of the phosphoenolpyruvate-sugar phosphotransferase system (PTS) of B. subtilis, S. aureus, and Staphylococcus carnosus, indicating an influence of the PTS on the mucoid phenotype in S. epidermidis. PMID:14532029
Prophylactic teicoplanin during insertion of Hickman catheters.
Lim, S H; Smith, M P; Machin, S J; Goldstone, A H
1990-12-01
With the extensive use of Hickman catheters in patients requiring cytotoxic chemotherapy there is now a resurgence of Gram-positive septicaemia among these patients during the neutropenic periods. We are currently running a prospective randomized study of prophylactic teicoplanin during insertion of Hickman catheters to determine if it reduces the incidence of Gram-positive septicaemia. A total of 44 patients have completed the study (23 in the teicoplanin group and 21 in the control group). The diagnoses were: acute myelogenous leukaemia (13), non-Hodgkin's lymphoma (16), Hodgkin's disease (11), chronic granulocytic leukaemia (3) and acute lymphoblastic leukaemia (1). The number of days between insertion of Hickman catheters and the development of neutropenia was: teicoplanin group: mean 14.7, median 11, range 0-53; control group: mean 11.8, median 10, range 0-37. In the treated patients, there were four episodes of line-associated Gram-positive septicaemia and a total of four organisms were isolated. In the control group, 10 organisms were isolated from a total of nine episodes of line-associated Gram-positive septicaemia. The organisms were: coagulase-negative staphylococci (8), Streptococcus B, (1), Strep. faecalis (1), Strep. mitis (1), alpha streptococcus (1), diphtheriods (1) and Staphylococcus aureus (1). All organisms were sensitive to teicoplanin. No adverse reaction was observed in any patient. Prophylactic teicoplanin during insertion of Hickman catheters may therefore reduce the incidence of line-associated Gram-positive septicaemia in neutropenic patients.
An evaluation of sterilization of endodontic instruments in artificial sponges.
Vélez, A E; Thomas, D D; del Río, C E
1998-01-01
The ability to sterilize endodontic files inserted into synthetic sponges was tested. Sponges were subjected to 5 cycles of either dry heat (Driclave) or steam under pressure (autoclave) sterilization. Sterilization was corroborated by microbiological tests. The sponges and files were pre-sterilized separately using steam under pressure. One hundred eighty files contaminated with Bacillus stearothermophilus spores (experimental and positive control) and 60 noncontaminated files (negative control), were inserted into 60 sponges. After each cycle, each file and a portion of sponge surrounding the file were transferred aseptically to tubes containing trypticase soy broth culture medium for bacteriological analysis. None of the tubes containing files and portions of sponges that were subjected to autoclave grew Bacillus stearothermophilus spores. Two of 60 (3.33%) of the tubes that were subjected to sterilization by Driclave demonstrated bacterial growth. Although the sponges tolerated the dry heat cycles well physically, sterilization was achieved in only 96.67% of the cases.
Wang, Chuan; Kokkonen, Heidi; Sandling, Johanna K; Johansson, Martin; Seddighzadeh, Maria; Padyukov, Leonid; Rantapää-Dahlqvist, Solbritt; Syvänen, Ann-Christine
2011-10-01
Two interferon regulatory factor 5 (IRF5) gene variants were examined for association with rheumatoid arthritis (RA). A total of 2300 patients with RA and 1836 controls were recruited from 2 independent RA studies in Sweden. One insertion-deletion polymorphism (CGGGG indel) and one single-nucleotide polymorphism (rs10488631) in the IRF5 gene were genotyped and analyzed within RA subgroups stratified by rheumatoid factor (RF) and anticitrullinated peptide antibodies (ACPA). The CGGGG indel was preferentially associated with the RF-negative (OR 1.29, p = 7.9 × 10(-5)) and ACPA-negative (OR 1.27, p = 7.3 × 10(-5)) RA subgroups compared to the seropositive counterparts. rs10488631 was exclusively associated within the seronegative RA subgroups (RF-negative: OR 1.24, p = 0.016; ACPA-negative: OR 1.27, p = 4.1 × 10(-3)). Both the CGGGG indel and rs10488631 are relevant for RA susceptibility, especially for seronegative RA.
Dinesh Kumar, K. K.; Bhardwaj, Neerja; Yaddanapudi, Sandhya
2017-01-01
Background and Aims: It is not known whether trapezius squeeze test (TPZ) is a better clinical test than jaw thrust (JT) to assess laryngeal mask airway (LMA) insertion conditions in children under sevoflurane anesthesia. Material and Methods: After the Institutional Ethics Committee approval and written informed parental consent, 124 American Society of Anesthesiologists I and II children of 2–8 years of age undergoing minor surgical procedures were randomized into TPZ and JT groups. The children were induced with 8% sevoflurane in oxygen at a fresh gas flow of 4 L/min. TPZ or JT was performed after 1 min of start of sevoflurane and then every 20 s till the test was negative, when end-tidal (ET) sevoflurane concentration was noted. Classic LMA of requisite size was inserted by a blinded anesthetist and conditions at the insertion of LMA, insertion time, and the number of attempts of LMA insertion were recorded. Results: The mean LMA insertion time was significantly longer (P < 0.001) for TPZ (145 ± 28.7 sec) compared to JT group (111.8 ± 31.0 sec). ET sevoflurane concentration at the time of LMA insertion was comparable in the two groups. LMA insertion conditions were similar in the two groups. There was no difference between the two groups regarding total number of attempts of LMA insertion. Heart rate (HR) decreased in both groups after LMA insertion (P < 0.001) but TPZ group had significantly lower HR compared with the JT group up to 5 min after LMA insertion (P = 0.03). Conclusion: Both JT and TPZ are equivalent clinical indicators in predicting the optimal conditions of LMA insertion in spontaneously breathing children; however, it takes a longer time to achieve a negative TPZ squeeze test. PMID:28413275
Antimicrobial Decapeptide KSL-W Enhances Neutrophil Chemotaxis and Function
2011-12-16
counting on hemacytometer (Hausser Scientific, Horsham, PA). Then, 8.5 × 104 cells in 75 l RPMI 1640 were transferred to the upper compartment (insert) of a...RPMI 1640 media, as the negative control. Neutrophils migrating across the membrane were quantified by counting vital cells in suspension via...Kasche A, Feser A, Ring J, Jakob T, Behrendt H. Chemotaxis and activation of human peripheral blood eosinophils induced by pollen -associated lipid
Millar, Brett M.; Starks, Tyrel J.; Grov, Christian; Parsons, Jeffrey T.
2017-01-01
The link between depression and sexual risk-taking has received mixed findings in the literature. The current study analyzed the links between depression and recent condomless anal sex (CAS) with casual partners among 1033 HIV-negative, non-PrEP-using, gay and bisexual men. When CAS was dichotomized as either none or some, depression was not associated with the odds of CAS (with receptive and insertive combined) or insertive CAS only, but was positively associated with the odds of receptive CAS. When CAS was tallied as a count variable of events, depression was positively associated with total CAS, receptive CAS, and insertive CAS. With the addition of a quadratic term for depression, a positive quadratic effect was only found for total CAS and receptive CAS, but not for insertive CAS. These findings highlight the utility of using count data for CAS events and treating CAS separately with regard to receptive and insertive positioning when considering the role of depression among gay and bisexual men. PMID:27475943
NASA Astrophysics Data System (ADS)
Morrison, Christopher
Nuclear fuels with similar aggregate material composition, but with different millimeter and micrometer spatial configurations of the component materials can have very different safety and performance characteristics. This research focuses on modeling and attempting to engineer heterogeneous combinations of nuclear fuels to improve negative prompt temperature feedback in response to reactivity insertion accidents. Improvements in negative prompt temperature feedback are proposed by developing a tailored thermal resistance in the nuclear fuel. In the event of a large reactivity insertion, the thermal resistance allows for a faster negative Doppler feedback by temporarily trapping heat in material zones with strong absorption resonances. A multi-physics simulation framework was created that could model large reactivity insertions. The framework was then used to model a comparison of a heterogeneous fuel with a tailored thermal resistance and a homogeneous fuel without the tailored thermal resistance. The results from the analysis confirmed the fundamental premise of prompt temperature feedback and provide insights into the neutron spectrum dynamics throughout the transient process. A trade study was conducted on infinite lattice fuels to help map a design space to study and improve prompt temperature feedback with many results. A multi-scale fuel pin analysis was also completed to study more realistic geometries. The results of this research could someday allow for novel nuclear fuels that would behave differently than current fuels. The idea of having a thermal barrier coating in the fuel is contrary to most current thinking. Inherent resistance to reactivity insertion accidents could enable certain reactor types once considered vulnerable to reactivity insertion accidents to be reevaluated in light of improved negative prompt temperature feedback.
Posterior medial meniscus-femoral insertion into the anterior cruciate ligament. A case report.
Bhargava, A; Ferrari, D A
1998-03-01
Medial meniscal anomalies are rare. The anterior horn insertion into the anterior cruciate ligament is the most common. In the course of an arthroscopy for torn lateral meniscus, an anomalous band in continuity with the posterior horn of the medial meniscus was observed to insert into the anterior cruciate ligament. Although the tibial portion of the anterior cruciate was redundant, the anomalous band provided tension to the anterior cruciate ligament and a negative pivot shift. A previously unreported posterior medial meniscal femoral insertion is described.
A general insert label for peptide display on chimeric filamentous bacteriophages.
Kaplan, Gilad; Gershoni, Jonathan M
2012-01-01
The foreign insert intended to be displayed via recombinant phage proteins can have a negative effect on protein expression and phage assembly. A typical example is the case of display of peptides longer than 6 amino acid residues on the major coat protein, protein VIII of the filamentous bacteriophages M13 and fd. A solution to this problem has been the use of "two-gene systems" generating chimeric phages that concomitantly express wild-type protein VIII along with recombinant protein VIII. Although the two-gene systems are much more permissive in regard to insert length and composition, some cases can still adversely affect phage assembly. Although these phages genotypically contain the desired DNA of the insert, they appear to be phenotypically wild type. To avoid false-negative results when using chimeric phages in binding studies, it is necessary to confirm that the observed lack of phage recognition is not due to faulty assembly and display of the intended insert. Here we describe a strategy for generating antibodies that specifically recognize recombinant protein VIII regardless of the nature of its foreign insert. These antibodies can be used as a general monitor of the display of recombinant protein VIII into phage particles. Copyright © 2011 Elsevier Inc. All rights reserved.
Bonanno, Ludivine; Loukiadis, Estelle; Mariani-Kurkdjian, Patricia; Oswald, Eric; Garnier, Lucille; Michel, Valérie
2015-01-01
Shiga toxin-producing Escherichia coli (STEC) is a food-borne pathogen that may be responsible for severe human infections. Only a limited number of serotypes, including O26:H11, are involved in the majority of serious cases and outbreaks. The main virulence factors, Shiga toxins (Stx), are encoded by bacteriophages. Seventy-four STEC O26:H11 strains of various origins (including human, dairy, and cattle) were characterized for their stx subtypes and Stx phage chromosomal insertion sites. The majority of food and cattle strains possessed the stx1a subtype, while human strains carried mainly stx1a or stx2a. The wrbA and yehV genes were the main Stx phage insertion sites in STEC O26:H11, followed distantly by yecE and sbcB. Interestingly, the occurrence of Stx phages inserted in the yecE gene was low in dairy strains. In most of the 29 stx-negative E. coli O26:H11 strains also studied here, these bacterial insertion sites were vacant. Multilocus sequence typing of 20 stx-positive or stx-negative E. coli O26:H11 strains showed that they were distributed into two phylogenetic groups defined by sequence type 21 (ST21) and ST29. Finally, an EspK-carrying phage was found inserted in the ssrA gene in the majority of the STEC O26:H11 strains but in only a minority of the stx-negative E. coli O26:H11 strains. The differences in the stx subtypes and Stx phage insertion sites observed in STEC O26:H11 according to their origin might reflect that strains circulating in cattle and foods are clonally distinct from those isolated from human patients. PMID:25819955
The development of a cisgenic apple plant.
Vanblaere, Thalia; Szankowski, Iris; Schaart, Jan; Schouten, Henk; Flachowsky, Henryk; Broggini, Giovanni A L; Gessler, Cesare
2011-07-20
Cisgenesis represents a step toward a new generation of GM crops. The lack of selectable genes (e.g. antibiotic or herbicide resistance) in the final product and the fact that the inserted gene(s) derive from organisms sexually compatible with the target crop should rise less environmental concerns and increase consumer's acceptance. Here we report the generation of a cisgenic apple plant by inserting the endogenous apple scab resistance gene HcrVf2 under the control of its own regulatory sequences into the scab susceptible apple cultivar Gala. A previously developed method based on Agrobacterium-mediated transformation combined with a positive and negative selection system and a chemically inducible recombination machinery allowed the generation of apple cv. Gala carrying the scab resistance gene HcrVf2 under its native regulatory sequences and no foreign genes. Three cisgenic lines were chosen for detailed investigation and were shown to carry a single T-DNA insertion and express the target gene HcrVf2. This is the first report of the generation of a true cisgenic plant. Copyright © 2011 Elsevier B.V. All rights reserved.
MTR MAIN FLOOR. MEN DEMONSTRATE INSERTION OF DUMMY PLUG INTO ...
MTR MAIN FLOOR. MEN DEMONSTRATE INSERTION OF DUMMY PLUG INTO AN MTR BEAM HOLE. ONE MAN CHECKS RADIATION LEVEL AT THE END OF THE UNIVERSAL COFFIN, WHILE ANOTHER USES TOOL TO INSERT PLUG INTO HOLE THROUGH COFFIN. MEN WEAR "ANTI-C" (ANTI-CONTAMINATION) CLOTHING. INL NEGATIVE NO. 6198. R.G. Larsen, Photographer, 6/27/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Masking as an effective quality control method for next-generation sequencing data analysis.
Yun, Sajung; Yun, Sijung
2014-12-13
Next generation sequencing produces base calls with low quality scores that can affect the accuracy of identifying simple nucleotide variation calls, including single nucleotide polymorphisms and small insertions and deletions. Here we compare the effectiveness of two data preprocessing methods, masking and trimming, and the accuracy of simple nucleotide variation calls on whole-genome sequence data from Caenorhabditis elegans. Masking substitutes low quality base calls with 'N's (undetermined bases), whereas trimming removes low quality bases that results in a shorter read lengths. We demonstrate that masking is more effective than trimming in reducing the false-positive rate in single nucleotide polymorphism (SNP) calling. However, both of the preprocessing methods did not affect the false-negative rate in SNP calling with statistical significance compared to the data analysis without preprocessing. False-positive rate and false-negative rate for small insertions and deletions did not show differences between masking and trimming. We recommend masking over trimming as a more effective preprocessing method for next generation sequencing data analysis since masking reduces the false-positive rate in SNP calling without sacrificing the false-negative rate although trimming is more commonly used currently in the field. The perl script for masking is available at http://code.google.com/p/subn/. The sequencing data used in the study were deposited in the Sequence Read Archive (SRX450968 and SRX451773).
Cho, Byung-Yun; Yoon, Jung-Gyu
2015-08-01
[Purpose] The purpose of the current research was to identify how gait training with shoe inserts affects the pain and gait of sacroiliac joint dysfunction patients. [Subjects and Methods] Thirty subjects were randomly selected and assigned to be either the experimental group (gait training with shoe insert group) or control group. Each group consisted of 15 patients. Pain was measured by Visual Analogue Scale, and foot pressure in a standing position and during gait was measured with a Gateview AFA-50 system (Alpus, Seoul, Republic of Korea). A paired sample t-test was used to compare the pain and gait of the sacroiliac joint before and after the intervention. Correlation between pain and walking after gait training with shoe inserts was examined by Pearson test. The level of significance was set at α=0.05. [Results] It was found that application of the intervention to the experimental group resulted in a significant decrease in sacroiliac joint pain. It was also found that there was a significant correlation between Visual Analogue Scale score and dynamic asymmetric index (r= 0.796) and that there was a negative correlation between Visual Analogue Scale score and forefoot/rear foot peak pressure ratio (r=-0.728). [Conclusion] The results of our analysis lead us to conclude that the intervention with shoe inserts had a significant influence on the pain and gait of sacroiliac joint patients.
Cho, Byung-Yun; Yoon, Jung-Gyu
2015-01-01
[Purpose] The purpose of the current research was to identify how gait training with shoe inserts affects the pain and gait of sacroiliac joint dysfunction patients. [Subjects and Methods] Thirty subjects were randomly selected and assigned to be either the experimental group (gait training with shoe insert group) or control group. Each group consisted of 15 patients. Pain was measured by Visual Analogue Scale, and foot pressure in a standing position and during gait was measured with a Gateview AFA-50 system (Alpus, Seoul, Republic of Korea). A paired sample t-test was used to compare the pain and gait of the sacroiliac joint before and after the intervention. Correlation between pain and walking after gait training with shoe inserts was examined by Pearson test. The level of significance was set at α=0.05. [Results] It was found that application of the intervention to the experimental group resulted in a significant decrease in sacroiliac joint pain. It was also found that there was a significant correlation between Visual Analogue Scale score and dynamic asymmetric index (r= 0.796) and that there was a negative correlation between Visual Analogue Scale score and forefoot/rear foot peak pressure ratio (r=-0.728). [Conclusion] The results of our analysis lead us to conclude that the intervention with shoe inserts had a significant influence on the pain and gait of sacroiliac joint patients. PMID:26357428
Antimicrobial Activity of a Novel Vascular Access Film Dressing Containing Chlorhexidine Gluconate.
Wibaux, Anne; Thota, Priyaleela; Mastej, Jozef; Prince, Daniel L; Carty, Neal; Johnson, Peter
2015-01-01
Covering insertion sites with chlorhexidine impregnated dressings has been proven to be clinically effective in reducing catheter related blood stream infections (CR-BSI). Two chlorhexidine gluconate (CHG)-impregnated dressings are commercially available, a polyurethane foam disk and a film dressing containing a chlorhexidine gluconate-impregnated gel pad. While both have demonstrated efficacy in clinical settings, the major drawback of high cost and impaired IV insertion site visibility limits their usage. A new, simple film dressing containing CHG within its adhesive layer is now available. The objective of this study was to test the in vitro antimicrobial efficacy of the new dressing in comparison to the CHG-impregnated gel dressing. Quantitative aliquots of suspensions (concentration of 1.0x106 to 5.0x106 cfu/sample) of clinically relevant challenge organisms (Staphylococcus species, gram-negative bacilli, Candida albicans) were incubated in contact with the new CHG-containing film dressing, a placebo version of the same (negative control) and the commercially available CHG-impregnated gel dressing (positive control). Serial dilutions of the surviving organisms were quantified using the pour plate after 1, 3, 5, and 7 days of incubation in order to calculate an antimicrobial log10 reduction for each organism/dressing combination at each point in time. The new CHG-containing film dressing delivered greater than 5.0 log10 reduction throughout the 7 days on all aerobic gram-negative bacilli and Staphylococcus species tested. As of day 1 the CHG-containing film dressing provided greater than 5.0 log10 reduction on Candida albicans. There were no statistically significant differences in the log10 reduction between the two dressings tested. The new CHG-containing film dressing was found to be as effective as the chlorhexidine gluconate-impregnated gel dressing on clinically relevant microbes.
[Observation on gene polymorphism of Rh blood group in Chinese Han nationality].
Lan, Jiong-Cai; Wang, Cong-Rong; Wei, Ya-Ming; Zhou, Hua-You; Cao, Qiong; Zhang, Yin-Ze; Jiang, KuReXi; Wu, Da-Lin; Liu, Zhong
2003-12-01
To observe the gene polymorphism of Rh blood group in unrelated random individuals and families for Chinese Han nationality, polymerase chain reaction-sequence specific primer (PCR-SSP) was used to amplify the Rh C/E gene, RhD gene, exons, intron 2 and 10, insert and Rh Box in 160 blood samples of RhD positive unrelated individuals and 71 samples of RhD negative unrelated individuals and 7 samples of families whose probands were RhD-negative. The results showed that RhD genes of RhD-negative individuals with C antigens were polymorphism, three forms were found for D exon including intact, partial deletion and complete deletion exons. Insert fragments and Rh Box were found in most cases of families whose probands were RhD-negative and its inheritance accorded with the Mendel's Law, and it did not affect the expression of RhD gene. "Normal" RhD exon 4 amplifying product was not found in all of the samples. It was concluded that gene structure of the RhD-negative in Chinese was polymorphism, intact, partial deletion and complete deletion exons were found in the individuals with C antigen and probably existed specific D (nf) Ce haplotype. The function of insert was uncertain. The Rh gene sequences of Chinese Han nationality are different from those of Caucasian and the Rh gene library based on Han nationality should be established.
Cell wall elongation mode in Gram-negative bacteria is determined by peptidoglycan architecture.
Turner, Robert D; Hurd, Alexander F; Cadby, Ashley; Hobbs, Jamie K; Foster, Simon J
2013-01-01
Cellular integrity and morphology of most bacteria is maintained by cell wall peptidoglycan, the target of antibiotics essential in modern healthcare. It consists of glycan strands, cross-linked by peptides, whose arrangement determines cell shape, prevents lysis due to turgor pressure and yet remains dynamic to allow insertion of new material, and hence growth. The cellular architecture and insertion pattern of peptidoglycan have remained elusive. Here we determine the peptidoglycan architecture and dynamics during growth in rod-shaped Gram-negative bacteria. Peptidoglycan is made up of circumferentially oriented bands of material interspersed with a more porous network. Super-resolution fluorescence microscopy reveals an unexpected discontinuous, patchy synthesis pattern. We present a consolidated model of growth via architecture-regulated insertion, where we propose only the more porous regions of the peptidoglycan network that are permissive for synthesis.
Protein secretion and membrane insertion systems in gram-negative bacteria.
Saier, Milton H
2006-01-01
In contrast to other organisms, gram-negative bacteria have evolved numerous systems for protein export. Eight types are known that mediate export across or insertion into the cytoplasmic membrane, while eight specifically mediate export across or insertion into the outer membrane. Three of the former secretory pathway (SP) systems, type I SP (ISP, ABC), IIISP (Fla/Path) and IVSP (Conj/Vir), can export proteins across both membranes in a single energy-coupled step. A fourth generalized mechanism for exporting proteins across the two-membrane envelope in two distinct steps (which we here refer to as type II secretory pathways [IISP]) utilizes either the general secretory pathway (GSP or Sec) or the twin-arginine targeting translocase for translocation across the inner membrane, and either the main terminal branch or one of several protein-specific export systems for translocation across the outer membrane. We here survey the various well-characterized protein translocation systems found in living organisms and then focus on the systems present in gram-negative bacteria. Comparisons between these systems suggest specific biogenic, mechanistic and evolutionary similarities as well as major differences.
Walz, Antje-Christine; Demel, Rudy A; de Kruijff, Ben; Mutzel, Rupert
2002-01-01
sn-Glycerol-3-phosphate dehydrogenase (GlpD) from Escherichia coli is a peripheral membrane enzyme involved in respiratory electron transfer. For it to display its enzymic activity, binding to the inner membrane is required. The way the enzyme interacts with the membrane and how this controls activity has not been elucidated. In the present study we provide evidence for direct protein-lipid interaction. Using the monolayer technique, we observed insertion of GlpD into lipid monolayers with a clear preference for anionic phospholipids. GlpD variants with point mutations in their predicted amphipathic helices showed a decreased ability to penetrate anionic phospholipid monolayers. From these data we propose that membrane binding of GlpD occurs by insertion of an amphipathic helix into the acyl-chain region of lipids mediated by negatively charged phospholipids. PMID:11955283
Liu, J Z; Zhao, J; Zhang, Y J
2016-02-01
To compare the effectiveness of the jaw thrust and the trapezius squeezing test(TST) for laryngeal mask airway (LMA) insertion in infants and children under sevoflurane anesthesia. A total of 100 children aged from 6 month to 3 years, American Society of Anesthesiologists(ASA) Ⅰ-Ⅱ and undergoing minor operation were enrolled from January to June 2015 in Tianjin Children's Hospital. The patients were randomly divided into jaw thrusting group (Group J, n=50)and trapezius squeezing group(Group T, n=50). Anesthesia was induced with sevoflurane. When children's eyelash reflex lose, jaw thrust/trapezius squeeze was applied every 15 seconds.It's considered that the depth of anesthesia was not enough, and test reaction was positive if any movements of body, limbs or toes were found at the point of test. Sevoflurane should be keep on inhalation until negative test reaction was appeared. Then LMA was inserted immediately.The time required for the negative test, end-tidal sevoflurane concentrations (ETsev), the index of Narcotrend anesthesia monitor(NT), the occurrence of gross purposeful movements, coughing, gagging, breath-holding, laryngospasm or an SpO2 < 90% during LMA insertion in two groups of patients were observed and recorded. The condition of LMA insertion and the rate of successful insertion were evaluated. The blood pressure(BP), heart rate(HR) and SpO2 were also recorded before and after LMA insertion. In group J and group T, the time required for the negative test was (2.31±1.03) vs (2.85±0.97)min(t=-2.462, P<0.05), ETsev was(3.25±1.02)% vs (3.81±0.87) %(t=-2.361, P<0.05), the depth of anesthesia NT index was(50.41±5.38) vs (41.32±4.92)(t=3.021, all P<0.05). All of above results were significantly different. The successful rate of the first attempt LMA insertion was 78% vs 100%(χ(2)=12.36 , P<0.01), respectively. The differences had statistical significance. The conditions of LMA insertion in group T were superior to those in group J. The incidences of gross purposeful movements, coughing, gagging, breath-holding and SpO2<90% during LMA insertion in group J were 20%, 16%, 10%, 14% and 8%, which were higher than those in group T (2%, 2%, 0, 2%, 0), the differences were significant(χ(2)=8.27, 5.98, 5.26, 4.89, 4.17, all P<0.05). No significant change in blood pressure, heart rate and SpO2 were found before and after inserting LMA in two groups. The trapezius squeezing test is a superior indicator of adequate condition for LMA insertion compared to the jaw thrust in infants and young children under sevoflurane anesthesia.
Adhesion strength of sputtered TiAlN-coated WC insert tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Budi, Esmar; Razali, M. Mohd.; Nizam, A. R. Md.
2013-09-09
The adhesion strength of TiAlN coating that deposited by using DC magnetron sputtering on WC insert tool are studied. TiAlN coating are deposited on Tungsten Carbide (WC) insert tool by varying negatively substrate bias from 79 to 221 volt and nitrogen flow rate from 30 to 72 sccm. The adhesion strength are obtained by using Rockwell indentation test method with a Brale diamond at applied load of 60,100 and 150 kgf. The lateral diameter of indentation is plotted on three different applied loads and the adhesion strength of TiAlN coating was obtained from the curved slopes at 100 and 150more » kgf. The lower curve slop indicated better adhesion strength. The results shows that the adhesion strength of sputterred TiAlN coating tend to increase as the negatively substrate bias and nitrogen flow rate are increased.« less
Inoue, Takahiko; Yuo, Takahisa; Ohta, Takeshi; Hitomi, Eriko; Ichitani, Katsuyuki; Kawase, Makoto; Taketa, Shin; Fukunaga, Kenji
2015-08-01
Foxtail millet shows variation in positive phenol color reaction (Phr) and negative Phr in grains, but predominant accessions of this crop are negative reaction type, and the molecular genetic basis of the Phr reaction remains unresolved. In this article, we isolated polyphenol oxidase (PPO) gene responsible for Phr using genome sequence information and investigated molecular genetic basis of negative Phr and crop evolution of foxtail millet. First of all, we searched for PPO gene homologs in a foxtail millet genome database using a rice PPO gene as a query and successfully found three copies of the PPO gene. One of the PPO gene homologs on chromosome 7 showed the highest similarity with PPO genes expressed in hulls (grains) of other cereal species including rice, wheat, and barley and was designated as Si7PPO. Phr phenotypes and Si7PPO genotypes completely co-segregated in a segregating population. We also analyzed the genetic variation conferring negative Phr reaction. Of 480 accessions of the landraces investigated, 87 (18.1 %) showed positive Phr and 393 (81.9 %) showed negative Phr. In the 393 Phr negative accessions, three types of loss-of-function Si7PPO gene were predominant and independently found in various locations. One of them has an SNP in exon 1 resulting in a premature stop codon and was designated as stop codon type, another has an insertion of a transposon (Si7PPO-TE1) in intron 2 and was designated as TE1-insertion type, and the other has a 6-bp duplication in exon 3 resulting in the duplication of 2 amino acids and was designated as 6-bp duplication type. As a rare variant of the stop codon type, one accession additionally has an insertion of a transposon, Si7PPO-TE2, in intron 2 and was designated as "stop codon +TE2 insertion type". The geographical distribution of accessions with positive Phr and those with three major types of negative Phr was also investigated. Accessions with positive Phr were found in subtropical and tropical regions at frequencies of ca. 25-67 % and those with negative Phr were broadly found in Europe and Asia. The stop codon type was found in 285 accessions and was broadly distributed in Europe and Asia, whereas the TE-1 insertion type was found in 99 accessions from Europe and Asia but was not found in India. The 6-bp duplication type was found in only 8 accessions from Nansei Islands (Okinawa Prefecture) of Japan. We also analyzed Phr in the wild ancestor and concluded that the negative Phr type was likely to have originated after domestication of foxtail millet. It was also implied that negative Phr of foxtail millet arose by multiple independent loss of function of PPO gene through dispersal because of some advantages under some environmental conditions and human selection as in rice and barley.
Socket augmentation using a commercial collagen-based product--an animal study in pigs.
Kunert-Keil, Christiane; Gredes, Tomasz; Heinemann, Friedhelm; Dominiak, Marzena; Botzenhart, Ute; Gedrange, Tomasz
2015-01-01
The aim of the present study was to identify properties of pure collagen for augmentation techniques and compare to a proved xenogenic material and natural bone regeneration. For that the osteogenesis of extraction alveoli after augmentation with a collagen cone covered with an absorbable collagen membrane in a single product (PARASORB Sombrero®, Resorba) was evaluated in a pig model. Extraction alveoli were treated with the collagen cone and the collagen membrane in a single product (test group; n=7) or demineralized bovine bone mineral and a collagen membrane (two separate products; positive control; n=7). Untreated alveoli were used (n=6) as negative controls.(1) Bone specimens were extracted 1 and 3 months after teeth extraction. Serial longitudinal sections were stained with Masson Goldner trichrome. Furthermore, bone specimens were examined using X-ray analyses. Significant differences of bone atrophy were detected 12 weeks after material insertion using X-ray analyses. The bone atrophy was reduced by approximately 32% after insertion of the positive control (P=0.046). Bone atrophy reached 37.6% of those from untreated alveoli (P=0.002) using the test group. After 4 weeks, bone formation was noticeable in most sites, whereas after 12 weeks of healing, specimens of all groups exhibited nearly complete osseous organization of the former defected area. The mandibulary bone texture showed typical spongious bone structures. Histomorphometric analyses revealed after 4 and 12 weeks significant higher levels of bone marrow in test and negative control than in positive control. Quantification of bone tissue and osteoid does not show any significant difference. The present study confirms reduced bone resorption following socket augmentation with an absorbable collagen membrane with collagen cone while the resulting bone structure is similar to natural bone regeneration. Pure collagen can be used for bone augmentation, and shows over other xenogenic materials, a clear advantage with respect to the bone density and structure. Copyright © 2014 Elsevier B.V. All rights reserved.
Ito, Hiroya; Takahashi, Sayaka; Asai, Tetsuo; Tamura, Yutaka; Yamamoto, Koshi
2018-01-01
An atypical urease-negative mutant of Actinobacillus pleuropneumoniae serovar 2 was isolated in Japan. Nucleotide sequence analysis of the urease gene cluster revealed that the insertion of a short DNA sequence into the cbiM gene was responsible for the urease-negative activity of the mutant. Veterinary diagnostic laboratories should be watchful for the presence of aberrant urease-negative A. pleuropneumoniae isolates.
Su, Jiang-tao; Zhou, Qing-hui; Li, Rui; Zhang, Jie; Li, Wei-hong; Wang, Qiong
2010-08-01
To assess the immediate analgesic effect of wrist-ankle acupuncture on acute lumbago and the relationship between the analgesic effect and the expectation of patients. A randomized, single-blind, sham-controlled trial was designed. Sixty cases of acute lumbago were randomly divided into two groups, 30 cases in each one. In observation group, wrist-ankle acupuncture was adopted to the Lower 5 and Lower 6 bilaterally, no requirement of Deqi (arrival of qi). In control group, sham acupuncture was adopted. The treatment was applied once in either group, with the needles retained for 30 min. The Short-form McGill Pain Questionnaire (SF-MPQ) and the Modified-Modified Schober (MMS) test were used to assess the motion related pain and the situation of spinal flexion in 3 min before treatment and 5 min, 10 min, 15 min, during treatment and 30 min (needle removed), respectively. The Expectation and Treatment Credibility Scale (ETCS) was applied to analyze the relationship between the expectation of patients and the analgesic effect. The adverse reaction was recorded. There were no statistically significant differences in SF-MPQ, MMS and ETCS before treatment between two groups (all P>0.05). In 5 min after needles insertion, the scores of the items in SF-MPQ in observation group were lower than those in control group (P<0.05, P<0.01). In 10 min after needles insertion, the scores of SF-MPQ in observation group were lower than those in control group and the scores of MMS were higher than those in control group (P<0.05). In 15 min after needles insertion, except the sensory pain rating index, the scores of the rest items in SF-MPQ in observation group were all lower than those in control group (P<0.05, P<0.01). In 30 min (needles removed), the scores of affective pain rating index of SF-MPQ and Visual Analogue Scale (VAS) in observation group were lower than those in control group (P<0.05, P<0.01). The expectation before treatment was negatively correlated with VAS scores in 5 min, 10 min, 15 min and 30 min after needle insertion separately in observation group (P<0.05), while the correlation was not found in control group (P>0.05). No adverse reaction was reported. Wrist-ankle acupuncture can reduce acute lumbago immediately and significantly. The higher the expectation on the analgesic effect of wrist-ankle acupuncture the patients have, the better the analgesic effect will be. This therapy is highly safe in the treatment.
Lachowsky, Nathan J; Saxton, Peter J W; Hughes, Anthony J; Dickson, Nigel P; Milhausen, Robin R; Dewey, Cate E; Summerlee, Alastair J S
2016-02-01
Background Condom promotion remains a cornerstone of HIV/STI control, but must be informed by evidence of uptake and address disparities in use. This study sought to determine the prevalence of, and demographic, behavioural and relational factors associated with, condom use during insertive and receptive anal intercourse with casual partners among younger gay, bisexual and other men who have sex with men (YMSM) in New Zealand. The 2006-2011 national HIV behavioural surveillance data for YMSM aged 16-29 years was pooled. Separately for each sexual position, frequent (always/almost always) versus infrequent condom use was regressed onto explanatory variables using manual backward stepwise multivariable logistic regression analysis. Three-quarters of YMSM reported frequent condom use during insertive (76.0%) and receptive (73.8%) anal intercourse. YMSM who were exclusively insertive were more likely to report frequent condom use than versatile YMSM. Factors positively associated with frequent condom use, irrespective of sexual position were: in-person versus web-based recruitment, testing HIV negative versus never testing or testing HIV positive, having no recent sex with women, reporting two to five versus one male sexual partner in the past 6 months, reporting no current regular partner, but if in a regular relationship, reporting a boyfriend-type versus fuckbuddy-type partner, and frequent versus infrequent regular partner condom use. Pacific ethnicity and less formal education were negatively associated with frequent condom use only during receptive anal intercourse. The findings from this study demonstrate that condom norms can be actively established and maintained among YMSM. Condom promotion efforts must increase YMSM's capacity, agency and skills to negotiate condom use, especially for the receptive partner.
Validation of a dye stain assay for vaginally inserted HEC-filled microbicide applicators
Katzen, Lauren L.; Fernández-Romero, José A.; Sarna, Avina; Murugavel, Kailapuri G.; Gawarecki, Daniel; Zydowsky, Thomas M.; Mensch, Barbara S.
2011-01-01
Background The reliability and validity of self-reports of vaginal microbicide use are questionable given the explicit understanding that participants are expected to comply with study protocols. Our objective was to optimize the Population Council's previously validated dye stain assay (DSA) and related procedures, and establish predictive values for the DSA's ability to identify vaginally inserted single-use, low-density polyethylene microbicide applicators filled with hydroxyethylcellulose gel. Methods Applicators, inserted by 252 female sex workers enrolled in a microbicide feasibility study in Southern India, served as positive controls for optimization and validation experiments. Prior to validation, optimal dye concentration and staining time were ascertained. Three validation experiments were conducted to determine sensitivity, specificity, negative predictive values and positive predictive values. Results The dye concentration of 0.05% (w/v) FD&C Blue No. 1 Granular Food Dye and staining time of five seconds were determined to be optimal and were used for the three validation experiments. There were a total of 1,848 possible applicator readings across validation experiments; 1,703 (92.2%) applicator readings were correct. On average, the DSA performed with 90.6% sensitivity, 93.9% specificity, and had a negative predictive value of 93.8% and a positive predictive value of 91.0%. No statistically significant differences between experiments were noted. Conclusions The DSA was optimized and successfully validated for use with single-use, low-density polyethylene applicators filled with hydroxyethylcellulose (HEC) gel. We recommend including the DSA in future microbicide trials involving vaginal gels in order to identify participants who have low adherence to dosing regimens. In doing so, we can develop strategies to improve adherence as well as investigate the association between product use and efficacy. PMID:21992983
Gu, Yinghong; Zeng, Yi; Wang, Zhongshan; Dong, Changjiang
2017-11-21
Outer membrane (OM) β-barrel proteins play important roles in importing nutrients, exporting wastes and conducting signals in Gram-negative bacteria, mitochondria and chloroplasts. The outer membrane proteins (OMPs) are inserted and assembled into the OM by OMP85 family proteins. In Escherichia coli , the β-barrel assembly machinery (BAM) contains four lipoproteins such as BamB, BamC, BamD and BamE, and one OMP BamA, forming a 'top hat'-like structure. Structural and functional studies of the E. coli BAM machinery have revealed that the rotation of periplasmic ring may trigger the barrel β1C-β6C scissor-like movement that promote the unfolded OMP insertion without using ATP. Here, we report the BamA C-terminal barrel structure of Salmonella enterica Typhimurium str. LT2 and functional assays, which reveal that the BamA's C-terminal residue Trp, the β16C strand of the barrel and the periplasmic turns are critical for the functionality of BamA. These findings indicate that the unique β16C strand and the periplasmic turns of BamA are important for the outer membrane insertion and assembly. The periplasmic turns might mediate the rotation of the periplasmic ring to the scissor-like movement of BamA β1C-β6C, triggering the OMP insertion. These results are important for understanding the OMP insertion in Gram-negative bacteria, as well as in mitochondria and chloroplasts. © 2017 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.
Hurd, Wendy J; Kavros, Steven J; Kaufman, Kenton R
2010-11-01
Evaluate effects of a new off-the-shelf insert on frontal plane foot biomechanics and compare effectiveness of the new and an existing off-the-shelf insert and a motion-control shoe in neutralizing frontal plane foot biomechanics. Descriptive. Biomechanics laboratory. Fifteen uninjured subjects with a flexible flatfoot secondary to forefoot varus. Three-dimensional kinematic and kinetic data were collected as subjects walked and jogged at their self-selected speed while wearing a motion-control running shoe, the shoe with a new off-the-shelf insert, and the shoe with an existing off-the-shelf insert. Frontal plane kinematics and rearfoot kinetics were evaluated during stance. Statistical analysis was performed using a repeated measures analysis of variance and Student-Newman-Keuls post hoc tests (α ≤ 0.05). The new insert and motion-control shoe placed the forefoot in a less-everted position than the existing off-the-shelf insert during walking. There were no differences in forefoot kinematics during jogging, nor were there differences in rearfoot motion during walking or jogging. The rearfoot eversion moment was significantly lower with the new off-the-shelf insert compared with the motion-control shoe and the existing insert during walking and jogging. A new off-the-shelf device is available that promotes more neutral frontal plane biomechanics, thus providing a theoretical rationale for using this device for injury prevention and treatment. The comparative biomechanical effectiveness of a motion-control shoe and the orthotic inserts may assist health care professionals in selecting a device to correct the flatfoot structure.
Targeted σ factor turnover inserts negative control into a positive feedback loop
Donohue, Timothy J.
2009-01-01
Summary Since their classification as members of the σ70 super-family, Group IV alternative σ factors have been found to control gene expression in response to diverse environmental or stress signals. Activity of the Streptomyces coelicolor Group IV family member, σR (SigR), is increased by changes in the oxidation-reduction state of cytoplasmic disulphide bonds. Once released by its cognate anti-σ factor RsrA, σR activates expression of gene products that help cells reduce cytoplasmic disulphide bonds. In this issue of Molecular Microbiology, Kim and co-workers provide new insights into positive and negative control of σR activity. The authors show that a transcript derived from the inducible σR-dependent sigRrsrA p2 promoter operon encodes a σR protein of a higher molecular weight (termed σR′) than is found in uninduced cells. One major difference between σR′ and the smaller σR protein found in uninduced cells is the rapid proteolysis of σR′ by the ClpP1/P2 protease system. The genes for the ClpP1/ClpP2 protease subunits are themselves members of the σR regulon. The newly identified positive (σR′ synthesis) and negative control (selective σR′ turnover) aspects of this circuit are either found or predicted to exist in other related Group IV σ factor family members. PMID:19682265
Koo, Kyo Chul; Yoon, Jun-Ho; Park, No-Cheol; Lee, Hye Sun; Ahn, Hyun Kyu; Lee, Kwang Suk; Kim, Do Kyung; Cho, Kang Su; Chung, Byung Ha; Hong, Chang Hee
2018-06-01
Excessive bulking force during primary access of the ureteral access sheath may induce ureteral injury. We investigated the efficacy of preoperative α-blockade to reduce ureteral access sheath insertion force and determine the upper limit required to avoid ureteral injury. In this randomized controlled trial 135 patients from a single institution who had ureteropelvic junction or renal pelvis stones and were scheduled to undergo retrograde intrarenal surgery were prospectively enrolled from December 2015 to January 2017. Of the patients 41 and 42 were randomly assigned to the control and experimental groups, respectively. The experimental group received α-blockade preoperatively. The 21 patients who were pre-stented were assessed separately. We developed a homemade device to measure maximal ureteral access sheath insertion force. Our ureteral access sheath insertion force measurement device showed excellent reproducibility. Higher insertion velocity resulted in greater maximal sheath insertion force. Maximal insertion force in the α-blockade group was significantly lower than in the control group at the ureterovesical junction (p = 0.008) and the proximal ureter (p = 0.036). Maximal insertion force in the α-blockade group was comparable to that in pre-stented patients. Female patients and patients 70 years old or older showed a lower maximal ureteral access sheath insertion force than their counterparts. The rate of grade 2 or greater ureteral injury was lower in the α-blockade group than in controls (p = 0.038). No injury occurred in any case in which ureteral access sheath insertion force did not exceed 600 G. Preoperative α-blockade and slow sheath placement may reduce maximal ureteral access sheath insertion force. If the force exceeds 600 G, a smaller diameter sheath may be an alternative. Alternatively the procedure can be terminated and followed later by pre-stented retrograde intrarenal surgery. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Tajaddod, Mansoureh; Tanzer, Andrea; Licht, Konstantin; Wolfinger, Michael T; Badelt, Stefan; Huber, Florian; Pusch, Oliver; Schopoff, Sandy; Janisiw, Michael; Hofacker, Ivo; Jantsch, Michael F
2016-10-25
Short interspersed elements (SINEs) represent the most abundant group of non-long-terminal repeat transposable elements in mammalian genomes. In primates, Alu elements are the most prominent and homogenous representatives of SINEs. Due to their frequent insertion within or close to coding regions, SINEs have been suggested to play a crucial role during genome evolution. Moreover, Alu elements within mRNAs have also been reported to control gene expression at different levels. Here, we undertake a genome-wide analysis of insertion patterns of human Alus within transcribed portions of the genome. Multiple, nearby insertions of SINEs within one transcript are more abundant in tandem orientation than in inverted orientation. Indeed, analysis of transcriptome-wide expression levels of 15 ENCODE cell lines suggests a cis-repressive effect of inverted Alu elements on gene expression. Using reporter assays, we show that the negative effect of inverted SINEs on gene expression is independent of known sensors of double-stranded RNAs. Instead, transcriptional elongation seems impaired, leading to reduced mRNA levels. Our study suggests that there is a bias against multiple SINE insertions that can promote intramolecular base pairing within a transcript. Moreover, at a genome-wide level, mRNAs harboring inverted SINEs are less expressed than mRNAs harboring single or tandemly arranged SINEs. Finally, we demonstrate a novel mechanism by which inverted SINEs can impact on gene expression by interfering with RNA polymerase II.
Kessel, Boris; Olsha, Oded; Younis, Aurwa; Daskal, Yaakov; Granovsky, Emil; Alfici, Ricardo
2016-02-01
Gastrointestinal (GI) bleeding is a common surgical problem. The aim of this study was to evaluate how insertion of the nasogastric tube may enable differentiation between upper and lower GI bleeding in patients with melena. A retrospective study involving patients admitted to our surgery division with a melena was carried out between the years 2010 and 2012. A total of 386 patients were included in the study. Of these, 279 (72.2%) patients had negative nasogastric aspirate. The sensitivity of examination of nasogastric aspirate to establish the upper GI as the source of bleeding was only 28% and the negative predictive value of a negative nasogastric aspirate was less than 1%. Most patients who initially presented with melena and were found to have upper GI bleeding had a negative nasogastric aspirate. Insertion of a nasogastric tube does not affect the clinical decision to perform upper endoscopy and should not be routinely carried out.
Effect of cloacal plugging on microbial recovery from partially processed broilers.
Musgrove, M T; Cason, J A; Fletcher, D L; Stern, N J; Cox, N A; Bailey, J S
1997-03-01
Experiments were performed to test the contribution of bacteria contained in the intestinal tract of broilers at the beginning of processing to counts on the exterior of modified New York-dressed carcasses. Thirty-two birds were processed for each of seven replications. Within each replication, batches of four birds were electrocuted, scalded, and picked, with batches alternating between treatment and control groups. Treated birds were cloacally plugged with rayon fiber tampons prior to electrocution to prevent escape of intestinal contents during scalding and picking. Control birds were processed in the same manner, except that cloacal plugs were inserted immediately after defeathering to reduce escape of intestinal contents during sampling. Gram-negative enteric bacteria and Campylobacter spp. were enumerated on carcasses by whole carcass rinse procedure and in cecal contents. Counts were converted to log10 and subjected to analysis of variance. Cecal levels of Gram-negative enterics were significantly higher for plugged birds, but there was not a significant difference between levels of cecal Campylobacter spp. between treatment groups. Plugging before electrocution resulted in significantly lower levels (2.5 vs 3.0 log10 cfu/mL) of Campylobacter spp. and Gram-negative enteric bacteria (3.0 vs 3.4 log10 cfu/mL) in carcass rinses of treatment birds than in those of controls. All carcasses were positive for Gram-negative enterics. Cloacal plugging resulted in significantly lower incidence of Campylobacter spp. carcass contamination as determined by chi-square. Intestinal carriage of both campylobacters and Gram-negative enteric bacteria appears to influence the microbial quality of the carcass during processing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, S. H.; Tao, L. L.; Liu, D. P., E-mail: dpliu@iphy.ac.cn
We report a first principles theoretical investigation of spin polarized quantum transport in Mn{sub 2}Ga/MgO/Mn{sub 2}Ga and Mn{sub 3}Ga/MgO/Mn{sub 3}Ga magnetic tunneling junctions (MTJs) with the consideration of metal(Mg, Co, Cr) insertion layer effect. By changing the concentration of Mn, our calculation shows a considerable disparity in transport properties: A tunneling magnetoresistance (TMR) ratio of 852% was obtained for Mn{sub 2}Ga-based MTJs, however, only a 5% TMR ratio for Mn{sub 3}Ga-based MTJs. In addition, the influence of insertion layer has been considered in our calculation. We found the Co insertion layer can increase the TMR of Mn{sub 2}Ga-based MTJ tomore » 904%; however, the Cr insertion layer can decrease the TMR by 668%; A negative TMR ratio can be obtained with Mg insertion layer. Our work gives a comprehensive understanding of the influence of different insertion layer in Mn-Ga based MTJs. It is proved that, due to the transmission can be modulated by the interfacial electronic structure of insertion, the magnetoresistance ratio of Mn{sub 2}Ga/MgO/Mn{sub 2}Ga MTJ can be improved by inserting Co layer.« less
Antimicrobial Activity of a Novel Vascular Access Film Dressing Containing Chlorhexidine Gluconate
Wibaux, Anne; Thota, Priyaleela; Mastej, Jozef; Prince, Daniel L.; Carty, Neal; Johnson, Peter
2015-01-01
Background Covering insertion sites with chlorhexidine impregnated dressings has been proven to be clinically effective in reducing catheter related blood stream infections (CR-BSI). Two chlorhexidine gluconate (CHG)-impregnated dressings are commercially available, a polyurethane foam disk and a film dressing containing a chlorhexidine gluconate-impregnated gel pad. While both have demonstrated efficacy in clinical settings, the major drawback of high cost and impaired IV insertion site visibility limits their usage. A new, simple film dressing containing CHG within its adhesive layer is now available. The objective of this study was to test the in vitro antimicrobial efficacy of the new dressing in comparison to the CHG-impregnated gel dressing. Methods Quantitative aliquots of suspensions (concentration of 1.0x106 to 5.0x106 cfu/sample) of clinically relevant challenge organisms (Staphylococcus species, gram-negative bacilli, Candida albicans) were incubated in contact with the new CHG-containing film dressing, a placebo version of the same (negative control) and the commercially available CHG-impregnated gel dressing (positive control). Serial dilutions of the surviving organisms were quantified using the pour plate after 1, 3, 5, and 7 days of incubation in order to calculate an antimicrobial log10 reduction for each organism/dressing combination at each point in time. Results The new CHG-containing film dressing delivered greater than 5.0 log10 reduction throughout the 7 days on all aerobic gram-negative bacilli and Staphylococcus species tested. As of day 1 the CHG-containing film dressing provided greater than 5.0 log10 reduction on Candida albicans. There were no statistically significant differences in the log10 reduction between the two dressings tested. Conclusion The new CHG-containing film dressing was found to be as effective as the chlorhexidine gluconate-impregnated gel dressing on clinically relevant microbes. PMID:26599087
RELAP5 Application to Accident Analysis of the NIST Research Reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baek, J.; Cuadra Gascon, A.; Cheng, L.Y.
Detailed safety analyses have been performed for the 20 MW D{sub 2}O moderated research reactor (NBSR) at the National Institute of Standards and Technology (NIST). The time-dependent analysis of the primary system is determined with a RELAP5 transient analysis model that includes the reactor vessel, the pump, heat exchanger, fuel element geometry, and flow channels for both the six inner and twenty-four outer fuel elements. A post-processing of the simulation results has been conducted to evaluate minimum critical heat flux ratio (CHFR) using the Sudo-Kaminaga correlation. Evaluations are performed for the following accidents: (1) the control rod withdrawal startup accidentmore » and (2) the maximum reactivity insertion accident. In both cases the RELAP5 results indicate that there is adequate margin to CHF and no damage to the fuel will occur because of sufficient coolant flow through the fuel channels and the negative scram reactivity insertion.« less
Simmons, Michael J; Haley, Kevin J; Grimes, Craig D; Raymond, John D; Niemi, Jarad B
2002-01-01
Drosophila were genetically transformed with a hobo transgene that contains a terminally truncated but otherwise complete P element fused to the promoter from the Drosophila hsp70 gene. Insertions of this H(hsp/CP) transgene on either of the major autosomes produced the P transposase in both the male and female germlines, but not in the soma. Heat-shock treatments significantly increased transposase activity in the female germline; in the male germline, these treatments had little effect. The transposase activity of two insertions of the H(hsp/CP) transgene was not significantly greater than their separate activities, and one insertion of this transgene reduced the transposase activity of P(ry(+), Delta2-3)99B, a stable P transgene, in the germline as well as in the soma. These observations suggest that, through alternate splicing, the H(hsp/CP) transgene produces a repressor that feeds back negatively to regulate transposase expression or function in both the somatic and germline tissues. The H(hsp/CP) transgenes are able to induce gonadal dysgenesis when the transposase they encode has P-element targets to attack. However, this ability and the ability to induce P-element excisions are repressed by the P cytotype, a chromosomal/cytoplasmic state that regulates P elements in the germline. PMID:12019234
Study for new hardmask process scheme
NASA Astrophysics Data System (ADS)
Lee, Daeyoup; Tatti, Phillip; Lee, Richard; Chang, Jack; Cho, Winston; Bae, Sanggil
2017-03-01
Hardmask processes are a key technique to enable low-k semiconductors, but they can have an impact on patterning control, influencing defectivity, alignment, and overlay. Specifically, amorphous carbon layer (ACL) hardmask schemes can negatively affect overlay by creating distorted alignment signals. A new scheme needs to be developed that can be inserted where amorphous carbon is used but provide better alignment performance. Typical spin-on carbon (SOC) materials used in other hardmask schemes have issues with DCD-FCD skew. In this paper we will evaluate new spin-on carbon material with a higher carbon content that could be a candidate to replace amorphous carbon.
Relationship between footwear comfort of shoe inserts and anthropometric and sensory factors.
Mündermann, A; Stefanyshyn, D J; Nigg, B M
2001-11-01
The purposes of this study were (a) to determine lower extremity anthropometric and sensory factors that are related to differences in comfort perception of shoe inserts with varying shape and material and (b) to investigate whether shoe inserts that improve comfort decrease injury frequency in a military population. 206 military personnel volunteered for this study. The shoe inserts varied in arch and heel cup shape, hardness, and elasticity in the heel and forefoot regions. A no insert condition was included as the control condition. Measured subject characteristics included foot shape, foot and leg alignment, and tactile and vibration sensitivity of the plantar surface of the foot. Footwear comfort was assessed using a visual analog scale. Injury frequency was evaluated with a questionnaire. The statistical analyses included Student's t-tests for repeated measures, ANOVA (within subjects), MANOVA (within insert combinations), and chi-square tests. The average comfort ratings for all shoe inserts were significantly higher than the average comfort rating for the control condition. The incidence of stress fractures and pain at different locations was reduced by 1.5-13.4% for the insert compared with the control group. Foot arch height, foot and leg alignment, and foot sensitivity were significantly related to differences in comfort ratings for the hard/soft, the viscous/elastic, and the high arch/low arch insert combinations. Shoe inserts of different shape and material that are comfortable are able to decrease injury frequency. The results of this study showed that subject specific characteristics influence comfort perception of shoe inserts.
M13 procoat protein insertion into YidC and SecYEG proteoliposomes and liposomes.
Stiegler, Natalie; Dalbey, Ross E; Kuhn, Andreas
2011-02-25
M13 procoat protein was one of the first model proteins used to study bacterial membrane protein insertion. It contains a signal peptide of 23 amino acid residues and is not membrane targeted by the signal recognition particle. The translocation of its periplasmic domain is independent of the preprotein translocase (SecAYEG) but requires electrochemical membrane potential and the membrane insertase YidC of Escherichia coli. We show here that YidC is sufficient for efficient membrane insertion of the purified M13 procoat protein into energized YidC proteoliposomes. When no membrane potential is applied, the insertion is substantially reduced. Only in the presence of YidC, membrane insertion occurs if bilayer integrity is preserved and membrane potential is stable for more than 20 min. A mutant of the M13 procoat protein, H5EE, with two additional negatively charged residues in the periplasmic domain inserted into YidC proteoliposomes and SecYEG proteoliposomes with equal efficiencies. We conclude that the protein can use both the YidC-only pathway and the Sec pathway. This poses the questions of how procoat H5EE is inserted in vivo and how insertion pathways are selected in the cell. Copyright © 2011 Elsevier Ltd. All rights reserved.
Kristiniak, Susan; Harpel, Jean; Breckenridge, Diane M; Buckle, Jane
2012-11-01
To evaluate the effect of topically applied black pepper essential oil on easing intravenous catheter insertion (IVC) in patients with no palpable or visible veins compared to a control group (standard nursing practice). Randomized, controlled study. One hundred twenty hospitalized patients, who were referred to a hospital vascular team because of difficulty in accessing veins for IVC insertion. Topical application of 20% essential oil of black pepper in aloe vera gel or standard nursing care (hot packs with or without vigorous tactile stimulation). Pre- and post-test vein visibility and/or palpability and number of attempts at IVC insertion. A higher percentage of patients achieved optimal scoring (vein score=2) or improved scoring (vein score of 1 or 2) to black pepper intervention than standard nursing care. The black pepper group also reduced the number of patients whose veins were still not visible or palpable after the intervention to nearly half that of the control group (p<0.05). The number of IVC attempts following black pepper was also half that of the control group. Topical application of black pepper is a viable and effective way to enhance vein visibility and palpability prior to intravenous insertion in patients with limited vein accessibility; it also improves ease of IVC insertion.
Keller, Marla J; Buckley, Niall; Katzen, Lauren L; Walsh, Jennifer; Friedland, Barbara; Littlefield, Sarah; Lin, Juan; Xue, Xiaonan; Cornelison, Terri; Herold, Betsy C; Einstein, Mark H
2013-12-01
Applicator dye staining and ultraviolet (UV) light have been used in trials to measure adherence, but not in the setting of before and after sex gel dosing (BAT-24). This study was designed to determine if semen or presex gel dosing impacts the sensitivity and specificity of a dye stain assay (DSA) for measuring vaginal insertion of placebo-filled applicators with BAT-24 dosing. Healthy monogamous couples received Microlax-type applicators (Tectubes, Åstorp, Sweden) filled with hydroxyethylcelluose placebo gel. Women were instructed to vaginally insert 1 dose of gel before and a second dose after sex and to return applicators within 48 hours after sex. Applicators were stained to detect semen, followed by UV then DSA, and scored by 2 readers. Positive and negative controls were randomly included in applicator batches. Fifteen couples completed the study. Each woman returned at least 6 applicators over a 30-day period. The sensitivity for insertion of postsex applicators was higher for UV (97%) compared with DSA (90%), and the specificity was similar (≥96%). For presex applicators, the sensitivity and specificity were higher for DSA (100%) compared with UV testing (87% sensitivity, 96% specificity). Among returned postsex applicators, 95% tested positive by UV compared with 87% by DSA. Agreement between readers was significantly better on the presex applicators for DSA than for UV, and for postsex readings, agreement was less than half that for UV, although the results were not statistically significant. Applicator tests are feasible for measuring adherence in trials with gel dosing before and after sex.
Status of the Superconducting Insertion Device Control at TLS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, K. H.; Wang, C. J.; Lee, Demi
2007-01-19
Superconducting insertion devices are installed at Taiwan Light Source to meet the rapidly growing demand of X-ray users. A control system supports the operation of all these superconducting insertion devices. Control system coordinates the operation of the main power supply and the trimming power supply to charge/discharge the magnet and provide essential interlock protection for the coils and vacuum ducts. Quench protection and various cryogenic interlocks are designed to prevent damage to the magnet. A friendly user interface supports routine operation. Various applications are also developed to aid the operation of these insertion devices. Design consideration and details of themore » implementation will be summarized in this report.« less
Soon, Reni; Tschann, Mary; Salcedo, Jennifer; Stevens, Katelyn; Ahn, Hyeong Jun; Kaneshiro, Bliss
2017-08-01
To evaluate the efficacy of a paracervical block to decrease pain during osmotic dilator insertion before second-trimester abortion. In this double-blind, randomized trial, 41 women undergoing Laminaria insertion before a second-trimester abortion received either a paracervical block with 18 mL 1% lidocaine and 2 mL sodium bicarbonate or a sham block. Women were between 14 and 23 6/7 weeks of gestation. The primary outcome was pain immediately after insertion of Laminaria. Women assessed their pain on a 100-mm visual analog scale. Secondary outcomes included assessment of pain at other times during the insertion procedure and overall satisfaction with pain control. To detect a 25-mm difference in pain immediately after Laminaria insertion, at an α of 0.05 and 80% power, we aimed to enroll 20 patients in each arm. From May 2015 to December 2015, 20 women received a paracervical block and 21 received a sham block. Groups were similar in demographics, including parity, history of surgical abortion, and number of Laminaria placed. The paracervical block reduced pain after Laminaria insertion (median scores 13 mm [interquartile range 2-39] compared with 54 mm [interquartile range 27-61], P=.01, 95% CI -47.0 to -4.0). Women who received a paracervical block also reported higher satisfaction with overall pain control throughout the entire Laminaria insertion procedure (median scores 95 mm [interquartile range 78-100] compared with 70 mm [interquartile range 44-90], P=.05, 95% CI 0.0-37.0). Paracervical block is effective at reducing the pain of Laminaria insertion. Additionally, a paracervical block increases overall patient satisfaction with pain control during Laminaria placement. ClinicalTrials.gov, NCT02454296.
Lee, S K; Kim, Y H; Moon, K H; Choy, W S
2018-02-01
Extension-block pinning represents a simple and reliable surgical technique. Although this procedure is commonly performed successfully, some patients develop postoperative extension loss. To date, the relationship between extension-block Kirschner wire (K-wire) insertion angle and postoperative extension loss in mallet finger fracture remains unclear. We aimed to clarify this relationship and further evaluate how various operative and non-operative factors affect postoperative extension loss after extension-block pinning for mallet finger fracture. A retrospective study was conducted to investigate a relationship between extension block K-wire insertion angle and postoperative extension loss. The inclusion criteria were: (1) a dorsal intra-articular fracture fragment involving 30% of the base of the distal phalanx with or without volar subluxation of the distal phalanx; and (2) <3 weeks delay from the injury without treatment. Extension-block K-wire insertion angle and fixation angle of the distal interphalangeal (DIP) joint were assessed using lateral radiograph at immediate postoperative time. Postoperative extension loss was assessed by using lateral radiograph at latest follow-up. Extension-block K-wire insertion angle was defined as the acute angle between extension block K-wire and longitudinal axis of middle phalangeal head. DIP joint fixation angle was defined as the acute angle between the distal phalanx and middle phalanx longitudinal axes. Seventy-five patients were included. The correlation analysis revealed that extension-block K-wire insertion angle had a negative correlation with postoperative extension loss, whereas fracture size and time to operation had a positive correlation (correlation coefficient for extension block K-wire angle: -0.66, facture size: +0.67, time to operation: +0.60). When stratifying patients in terms of negative and positive fixation angle of the DIP joint, the independent t-test showed that mean postoperative extension loss is -3.67° and +4.54° (DIP joint fixation angles of <0° and ≥0°, respectively, P=0.024). When stratifying patients in terms of extension-block K-wire insertion angle (30°, 30°-40°, >40°), ANOVA showed significantly less postoperative extension loss for higher insertion angles (>40°) than for medium insertion angles (30°-40°). Mean postoperative extension loss difference between higher insertion angle (>40°) and medium insertion angle (30°-40°) was 11° (P=0.002). Using an insertion angle of the extension-block K-wire of 40°-45° and a slightly hyperextended position of the DIP joint may help reducing postoperative extension loss. Therapeutic level III. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
NASA Technical Reports Server (NTRS)
Zipf, Mark E.
1989-01-01
An overview is presented of research work focussed on the design and insertion of classical models of human pilot dynamics within the flight control loops of V/STOL aircraft. The pilots were designed and configured for use in integrated control system research and design. The models of human behavior that were considered are: McRuer-Krendel (a single variable transfer function model); and Optimal Control Model (a multi-variable approach based on optimal control and stochastic estimation theory). These models attempt to predict human control response characteristics when confronted with compensatory tracking and state regulation tasks. An overview, mathematical description, and discussion of predictive limitations of the pilot models is presented. Design strategies and closed loop insertion configurations are introduced and considered for various flight control scenarios. Models of aircraft dynamics (both transfer function and state space based) are developed and discussed for their use in pilot design and application. Pilot design and insertion are illustrated for various flight control objectives. Results of pilot insertion within the control loops of two V/STOL research aricraft (Sikorski Black Hawk UH-60A, McDonnell Douglas Harrier II AV-8B) are presented and compared against actual pilot flight data. Conclusions are reached on the ability of the pilot models to adequately predict human behavior when confronted with similar control objectives.
Seiberlich, Laura E; Keay, Vanessa; Kallos, Stephane; Junghans, Tiffany; Lang, Eddy; McRae, Andrew D
2016-03-01
The performance of a new safety peripheral intravenous catheter (PIVC) that contains a blood control feature in the hub (blood control) was compared against the current hospital standard without blood control (standard). In this prospective, non-blinded trial, patients were randomized 1:1 to receive either device. Insertions were performed and rated by emergency room nurses. Primary endpoints included clinical acceptability, incidence of blood leakage, and risk of blood exposure. Secondary endpoints were digital compression, insertion success, and usability. 15 clinicians performed 152 PIVC insertions (73 blood control, 79 standard). Clinical acceptability of the blood control device (100%) was non-inferior to the standard (98.7%) (p < 0.0001). The blood control device had a lower incidence of blood leakage (14.1% vs 68.4%), was superior in eliminating the risk of blood exposure (93.9% vs 19.1%) and the need for digital compression (95.3% vs 19.1%), while maintaining non-inferior insertion success rates (95.9% vs 93.7%) and usability ratings (p < 0.0001). In comparison with the hospital-standard, the new safety PIVC with integrated blood control valve had similar clinical acceptability ratings yet demonstrated superior advantages to both clinicians and patients to decrease blood leakage and the clinician's risk of blood exposure, during the insertion process. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
On the Control of the Fixed Charge Densities in Al2O3-Based Silicon Surface Passivation Schemes.
Simon, Daniel K; Jordan, Paul M; Mikolajick, Thomas; Dirnstorfer, Ingo
2015-12-30
A controlled field-effect passivation by a well-defined density of fixed charges is crucial for modern solar cell surface passivation schemes. Al2O3 nanolayers grown by atomic layer deposition contain negative fixed charges. Electrical measurements on slant-etched layers reveal that these charges are located within a 1 nm distance to the interface with the Si substrate. When inserting additional interface layers, the fixed charge density can be continuously adjusted from 3.5 × 10(12) cm(-2) (negative polarity) to 0.0 and up to 4.0 × 10(12) cm(-2) (positive polarity). A HfO2 interface layer of one or more monolayers reduces the negative fixed charges in Al2O3 to zero. The role of HfO2 is described as an inert spacer controlling the distance between Al2O3 and the Si substrate. It is suggested that this spacer alters the nonstoichiometric initial Al2O3 growth regime, which is responsible for the charge formation. On the basis of this charge-free HfO2/Al2O3 stack, negative or positive fixed charges can be formed by introducing additional thin Al2O3 or SiO2 layers between the Si substrate and this HfO2/Al2O3 capping layer. All stacks provide very good passivation of the silicon surface. The measured effective carrier lifetimes are between 1 and 30 ms. This charge control in Al2O3 nanolayers allows the construction of zero-fixed-charge passivation layers as well as layers with tailored fixed charge densities for future solar cell concepts and other field-effect based devices.
2015-01-01
A hallmark of penicillin-binding protein 2 (PBP2) from penicillin-resistant strains of Neisseria gonorrhoeae is insertion of an aspartate after position 345. The insertion resides on a loop near the active site and is immediately adjacent to an existing aspartate (Asp346) that forms a functionally important hydrogen bond with Ser363 of the SxN conserved motif. Insertion of other amino acids, including Glu and Asn, can also lower the rate of acylation by penicillin, but these insertions abolish transpeptidase function. Although the kinetic consequences of the Asp insertion are well-established, how it impacts the structure of PBP2 is unknown. Here, we report the 2.2 Å resolution crystal structure of a truncated construct of PBP2 containing all five mutations present in PBP2 from the penicillin-resistant strain 6140, including the Asp insertion. Commensurate with the strict specificity for the Asp insertion over similar amino acids, the insertion does not cause disordering of the structure, but rather induces localized flexibility in the β2c−β2d loop. The crystal structure resolves the ambiguity of whether the insertion is Asp345a or Asp346a (due to the adjacent Asp) because the hydrogen bond between Asp346 and Ser362 is preserved and the insertion is therefore Asp346a. The side chain of Asp346a projects directly toward the β-lactam-binding site near Asn364 of the SxN motif. The Asp insertion may lower the rate of acylation by sterically impeding binding of the antibiotic or by hindering breakage of the β-lactam ring during acylation because of the negative charge of its side chain. PMID:25403720
Fedarovich, Alena; Cook, Edward; Tomberg, Joshua; Nicholas, Robert A; Davies, Christopher
2014-12-09
A hallmark of penicillin-binding protein 2 (PBP2) from penicillin-resistant strains of Neisseria gonorrhoeae is insertion of an aspartate after position 345. The insertion resides on a loop near the active site and is immediately adjacent to an existing aspartate (Asp346) that forms a functionally important hydrogen bond with Ser363 of the SxN conserved motif. Insertion of other amino acids, including Glu and Asn, can also lower the rate of acylation by penicillin, but these insertions abolish transpeptidase function. Although the kinetic consequences of the Asp insertion are well-established, how it impacts the structure of PBP2 is unknown. Here, we report the 2.2 Å resolution crystal structure of a truncated construct of PBP2 containing all five mutations present in PBP2 from the penicillin-resistant strain 6140, including the Asp insertion. Commensurate with the strict specificity for the Asp insertion over similar amino acids, the insertion does not cause disordering of the structure, but rather induces localized flexibility in the β2c-β2d loop. The crystal structure resolves the ambiguity of whether the insertion is Asp345a or Asp346a (due to the adjacent Asp) because the hydrogen bond between Asp346 and Ser362 is preserved and the insertion is therefore Asp346a. The side chain of Asp346a projects directly toward the β-lactam-binding site near Asn364 of the SxN motif. The Asp insertion may lower the rate of acylation by sterically impeding binding of the antibiotic or by hindering breakage of the β-lactam ring during acylation because of the negative charge of its side chain.
Ober, Julian; Walker, Tilman; Bergdolt, Christian; Friedrich, Mirco; Müller-Stich, Beat Peter; Forchheim, Franziska; Fischer, Christian; Schmidmaier, Gerhard; Tanner, Michael C
2018-01-01
Background The insertion of a chest tube should be as quick and accurate as possible to maximize the benefit and minimize possible complications for the patient. Therefore, comprehensive training and assessment before an emergency situation are essential for proficiency in chest tube insertion. Serious games have become more prevalent in surgical training because they enable students to study and train a procedure independently, and errors made have no effect on patients. However, up-to-date evidence regarding the effect of serious games on performance in procedures in emergency medicine remains scarce. Objective The aim of this study was to investigate the serious gaming approach in teaching medical students an emergency procedure (chest tube insertion) using the app Touch Surgery and a modified objective structural assessment of technical skills (OSATS). Methods In a prospective, rater-blinded, randomized controlled trial, medical students were randomized into two groups: intervention group or control group. Touch Surgery has been established as an innovative and cost-free app for mobile devices. The fully automatic software enables users to train medical procedures and afterwards self-assess their training effort. The module chest tube insertion teaches each key step in the insertion of a chest tube and enables users the meticulous application of a chest tube. In contrast, the module “Thoracocentesis” discusses a basic thoracocentesis. All students attended a lecture regarding chest tube insertion (regular curriculum) and afterwards received a Touch Surgery training lesson: intervention group used the module chest tube insertion and the control group used Thoracocentesis as control training. Participants’ performance in chest tube insertion on a porcine model was rated on-site via blinded face-to-face rating and via video recordings using a modified OSATS tool. Afterwards, every participant received an individual questionnaire for self-evaluation. Here, trainees gave information about their individual training level, as well as previous experiences, gender, and hobbies. Primary end point was operative performance during chest tube insertion by direct observance. Results A total of 183 students enrolled, 116 students participated (63.4%), and 21 were excluded because of previous experiences in chest tube insertion. Students were randomized to the intervention group (49/95, 52%) and control group (46/95, 48%). The intervention group performed significantly better than the control group (Intervention group: 38.0 [I50=7.0] points; control group: 30.5 [I50=8.0] points; P<.001). The intervention group showed significantly improved economy of time and motion (P=.004), needed significantly less help (P<.001), and was more confident in handling of instruments (P<.001) than the control group. Conclusions The results from this study show that serious games are a valid and effective tool in education of operative performance in chest tube insertion. We believe that serious games should be implemented in the surgical curriculum, as well as residency programs, in addition to traditional learning methods. Trial Registration German Clinical Trials Register (DRKS) DRKS00009994; https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00009994 (Archived by Webcite at http://www.webcitation.org/6ytWF1CWg) PMID:29784634
Internally folded expanded metal electrode for battery construction
NASA Technical Reports Server (NTRS)
Pierce, Doug C. (Inventor); Korinek, Paul D. (Inventor); Morgan, Maurice C. (Inventor)
1993-01-01
A battery system is disclosed which includes folded grids of expanded metal inserted through non-conductive substrates and pasted with electrochemically active materials. In the most preferred embodiment, a frame is provided with a plastic insert, and slots are provided in the latter to receive the expanded metal grid. After suitable coinage of the grid and insertion through the plastic film, the grid is sealed and pasted on opposite sides with positive and negative active material. A battery is assembled using one or a plurality of the resulting electrode elements, with separators, to produce a high-power, lead-acid battery. The folded grid provides many of the design benefits of standard bipolar construction.
Dunn, R. C.; Laurie, C. C.
1995-01-01
Variation in the DNA sequence and level of alcohol dehydrogenase (Adh) gene expression in Drosophila melanogaster have been studied to determine what types of DNA polymorphisms contribute to phenotypic variation in natural populations. The Adh gene, like many others, shows a high level of variability in both DNA sequence and quantitative level of expression. A number of transposable element insertions occur in the Adh region and one of these, a copia insertion in the 5' flanking region, is associated with unusually low Adh expression. To determine whether this insertion (called RI42) causes the low expression level, the insertion was excised from the cloned RI42 Adh gene and the effect was assessed by P-element transformation. Removal of this insertion causes a threefold increase in the level of ADH, clearly showing that it contributes to the naturally occurring variation in expression at this locus. Removal of all but one LTR also causes a threefold increase, indicating that the mechanism is not a simple sequence disruption. Furthermore, this copia insertion, which is located between the two Adh promoters and their upstream enhancer sequences, has differential effects on the levels of proximal and distal transcripts. Finally, a test for the possible modifying effects of two suppressor loci, su(w(a)) and su(f), on this insertional mutation was negative, in contrast to a previous report in the literature. PMID:7498745
WATER PUMP HOUSE, TRA619, PUMP INSTALLATION. CAMERA FACING NORTHEAST CORNER. ...
WATER PUMP HOUSE, TRA-619, PUMP INSTALLATION. CAMERA FACING NORTHEAST CORNER. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION PRINTED ON THE ORIGINAL NEGATIVE. INL NEGATIVE NO. 3998. Unknown Photographer, 12/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Hornof, Margit; Weyenberg, Wim; Ludwig, Annick; Bernkop-Schnürch, Andreas
2003-05-20
The aim of the study was to develop a mucoadhesive ocular insert for the controlled delivery of ophthalmic drugs and to evaluate its efficacy in vivo. The inserts tested were based either on unmodified or thiolated poly(acrylic acid). Water uptake and swelling behavior of the inserts as well as the drug release rates of the model drugs fluorescein and two diclofenac salts with different solubility properties were evaluated in vitro. Fluorescein was used as fluorescent tracer to study the drug release from the insert in humans. The mean fluorescein concentration in the cornea/tearfilm compartment as a function of time was determined after application of aqueous eye drops and inserts composed of unmodified and of thiolated poly(acrylic acid). The acceptability of the inserts by the volunteers was also evaluated. Inserts based on thiolated poly(acrylic acid) were not soluble and had good cohesive properties. A controlled release was achieved for the incorporated model drugs. The in vivo study showed that inserts based on thiolated poly(acrylic acid) provide a fluorescein concentration on the eye surface for more than 8 h, whereas the fluorescein concentration rapidly decreased after application of aqueous eye drops or inserts based on unmodified poly(acrylic acid). Moreover, these inserts were well accepted by the volunteers. The present study indicates that ocular inserts based on thiolated poly(acrylic acid) are promising new solid devices for ocular drug delivery.
Linear motion device and method for inserting and withdrawing control rods
Smith, Jay E.
1984-01-01
A linear motion device, more specifically a control rod drive mechanism (CRDM) for inserting and withdrawing control rods into a reactor core, is capable of independently and sequentially positioning two sets of control rods with a single motor stator and rotor. The CRDM disclosed can control more than one control rod lead screw without incurring a substantial increase in the size of the mechanism.
Alvarez-Buylla, Elena R; García-Ponce, Berenice; Garay-Arroyo, Adriana
2006-01-01
APETALA1 (AP1) and CAULIFLOWER (CAL) are closely related MADS box genes that are partially redundant during Arabidopsis thaliana floral meristem determination. AP1 is able to fully substitute for CAL functions, but not vice versa, and AP1 has unique sepal and petal identity specification functions. In this study, the unique and redundant functions of these two genes has been mapped to the four protein domains that characterize type-II MADS-domain proteins by expressing all 15 chimeric combinations of AP1 and CAL cDNA regions under control of the AP1 promoter in ap1-1 loss-of-function plants. The "in vivo" function of these chimeric genes was analysed in Arabidopsis plants by expressing the chimeras. Rescue of flower meristem and sepal/petal identities was scored in single and multiple insert homozygous transgenic lines. Using these chimeric lines, it was found that distinct residues of the AP1 K domain not shared by the same CAL domain are necessary and sufficient for complete recovery of floral meristem identity, in the context of the CAL protein sequence, while both AP1 COOH and K domains are indispensable for complete rescue of sepal identity. By contrast, either one of these two AP1 domains is necessary and sufficient for complete petal identity recovery. It was also found that there were positive and negative synergies among protein domains and their combinations, and that multiple-insert lines showed relatively better rescue than equivalent single-insert lines. Finally, several lines had flowers with extra sepals and petals suggesting that chimeric proteins yield abnormal transcriptional complexes that may alter the expression or regulation of genes that control floral organ number under normal conditions.
Chiba, Shinobu; Ito, Koreaki
2015-01-01
The YidC/Oxa1/Alb3 family proteins are involved in membrane protein biogenesis in bacteria, mitochondria, and chloroplasts. Recent studies show that YidC uses a channel-independent mechanism to insert a class of membrane proteins into the membrane. Bacillus subtilis has two YidC homologs, SpoIIIJ (YidC1) and YidC2 (YqjG); the former is expressed constitutively, while the latter is induced when the SpoIIIJ activity is compromised. MifM is a substrate of SpoIIIJ, and its failure in membrane insertion is accompanied by stable ribosome stalling on the mifM-yidC2 mRNA, which ultimately facilitates yidC2 translation. While mutational inactivation of SpoIIIJ has been known to induce yidC2 expression, here, we show that the level of this induction is lower than that observed when the membrane insertion signal of MifM is defective. Moreover, this partial induction of YidC2 translation is lowered further when YidC2 is overexpressed in trans. These results suggest that YidC2 is able to insert MifM into the membrane and to release its translation arrest. Thus, under SpoIIIJ-deficient conditions, YidC2 expression is subject to MifM-mediated autogenous feedback repression. Our results show that YidC2 uses a mechanism that is virtually identical to that used by SpoIIIJ; Arg75 of YidC2 in its intramembrane yet hydrophilic cavity is functionally indispensable and requires negatively charged residues of MifM as an insertion substrate. From these results, we conclude that MifM monitors the total activities of the SpoIIIJ and the YidC2 pathways to control the synthesis of YidC2 and to maintain the cellular capability of the YidC mode of membrane protein biogenesis. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Michalovova, M; Vyskot, B; Kejnovsky, E
2013-10-01
We analysed the size, relative age and chromosomal localization of nuclear sequences of plastid and mitochondrial origin (NUPTs-nuclear plastid DNA and NUMTs-nuclear mitochondrial DNA) in six completely sequenced plant species. We found that the largest insertions showed lower divergence from organelle DNA than shorter insertions in all species, indicating their recent origin. The largest NUPT and NUMT insertions were localized in the vicinity of the centromeres in the small genomes of Arabidopsis and rice. They were also present in other chromosomal regions in the large genomes of soybean and maize. Localization of NUPTs and NUMTs correlated positively with distribution of transposable elements (TEs) in Arabidopsis and sorghum, negatively in grapevine and soybean, and did not correlate in rice or maize. We propose a model where new plastid and mitochondrial DNA sequences are inserted close to centromeres and are later fragmented by TE insertions and reshuffled away from the centromere or removed by ectopic recombination. The mode and tempo of TE dynamism determines the turnover of NUPTs and NUMTs resulting in their species-specific chromosomal distributions.
NASA Astrophysics Data System (ADS)
Akim, E. L.; Zaslavsky, G. S.; Morskoy, I. M.; Ruzsky, E. G.; Stepaniants, V. A.; Tuchin, A. G.
2010-02-01
This paper is concerned with the problems of ballistics, navigation, and flight control of the space craft (SC) in the Phobos-Grunt mission. We consider an insertion into the Earth-Mars transfer trajectory, the Earth-Mars transfer, the strategy of corrections, and the accuracy of the insertion of the SC into Martian orbit. During the orbital maneuvering stage in the sphere of influence of Mars, we set up a scheme that allows for the insertion of the SC, with the prescribed accuracy, into a point 80-km above the Phobos surface over the theoretical landing area. We specify the sequence for a controlled landing and provide methods for solving the problems of navigation and control during a self-c ontained landing. We also consider the liftoff from Phobos, insertion into the parking orbit, and the Mars-Earth transfer.
Evans, Megan L; Breeze, Janis L; Paulus, Jessica K; Meadows, Audra
The aim of this study was to assess the impact of a revolving loan fund (RLF) on timing of device insertion and long-acting reversible contraception (LARC) access among a high-risk urban population at 3 Boston community health centers. Three health centers were identified to implement a RLF. Each clinic received $5000 from the RLF to purchase LARC devices. Data collected through medical record review retrospectively 1 year prior to start of the RLF and prospectively for 1 year thereafter included patient demographics, type of LARC selected, patient's date of documented interest in a LARC device, and date of insertion. The effect of a RLF on delay to LARC insertion was tested using negative binomial regression, controlling for site and potential confounding variables between the pre- and post-RLF periods. Three urban community health centers. Reproductive-aged women who received family planning services at the 3 participating health centers. Increasing access to LARC and decreasing wait times to LARC insertion after implementation of the RLF. Data on 133 patients in the pre-RLF group and 205 in the post-RLF group were collected. There were no statistically significant differences in demographic or clinical characteristics between the 2 time periods. LARC uptake increased significantly from the pre- to post-RLF period, specifically among implant users. There was a statistically significant decrease in the mean number of days in delay from interest to insertion from the pre- to post-RLF period (pre-RLF: 31.3 ± 50.6 days; post-RLF: 13.6 ± 16.7 days, adjusted P < .001). The reasons for the delay did not differ significantly between the 2 time periods. The RLF decreased wait time for the devices and increased overall insertion rates. This may serve as a promising solution to improve LARC access in community health centers. This project could be expanded to include more health centers, creating a city wide RLF. This expansion could allow for further data analysis, including unintended pregnancy rates with LARC delay, LARC continuation rates, and sustainability of a RLF.
Su, ZhangFei; Shodiev, Muzaffar; Leitch, J Jay; Abbasi, Fatemeh; Lipkowski, Jacek
2018-05-29
The insertion and ion-conducting channel properties of alamethicin reconstituted into a 1,2-di- O-phytanyl- sn-glycero-3-phosphocholine bilayer floating on the surface of a gold (111) electrode modified with a 1-thio-β-d-glucose (β-Tg) self-assembled monolayer were investigated using a combination of electrochemical impedance spectroscopy (EIS) and polarization modulation infrared reflection absorption spectroscopy (PM-IRRAS). The hydrophilic β-Tg monolayer separated the bilayer from the gold substrate and created a water-rich spacer region, which better represents natural cell membranes. The EIS measurements acquired information about the membrane resistivity (a measure of membrane porosity), and the PM-IRRAS experiments provided insight into the conformation and orientation of the membrane constituents as a function of the transmembrane potential. The results showed that the presence of alamethicin had a small effect on the conformation and orientation of phospholipid molecules within the bilayer for all studied potentials. In contrast, the alamethicin peptides assumed a surface state, where the helical axes adopted a large tilt angle with respect to the surface normal, at small transmembrane potentials, and inserted into the bilayer at sufficiently negative transmembrane potentials forming pores, which behaved as barrel-stave ion channels for ionic transport across the membrane. The results indicated that insertion of alamethincin peptides into the bilayer was driven by the dipole-field interactions and that the transitions between the inserted and surface states were electrochemically reversible. Additionally, the EIS measurements performed on phospholipid bilayers without alamethicin also showed that the application of negative transmembrane potentials introduces defects into the bilayer. The membrane resistances measured in both the absence and presence of alamethicin show similar dependencies on the electrode potential, suggesting that the insertion of the peptide may also be assisted by the electroporation of the membrane. The findings in this study provide new insights into the mechanism of alamethicin insertion into phospholipid bilayers.
Haubruck, Patrick; Nickel, Felix; Ober, Julian; Walker, Tilman; Bergdolt, Christian; Friedrich, Mirco; Müller-Stich, Beat Peter; Forchheim, Franziska; Fischer, Christian; Schmidmaier, Gerhard; Tanner, Michael C
2018-05-21
The insertion of a chest tube should be as quick and accurate as possible to maximize the benefit and minimize possible complications for the patient. Therefore, comprehensive training and assessment before an emergency situation are essential for proficiency in chest tube insertion. Serious games have become more prevalent in surgical training because they enable students to study and train a procedure independently, and errors made have no effect on patients. However, up-to-date evidence regarding the effect of serious games on performance in procedures in emergency medicine remains scarce. The aim of this study was to investigate the serious gaming approach in teaching medical students an emergency procedure (chest tube insertion) using the app Touch Surgery and a modified objective structural assessment of technical skills (OSATS). In a prospective, rater-blinded, randomized controlled trial, medical students were randomized into two groups: intervention group or control group. Touch Surgery has been established as an innovative and cost-free app for mobile devices. The fully automatic software enables users to train medical procedures and afterwards self-assess their training effort. The module chest tube insertion teaches each key step in the insertion of a chest tube and enables users the meticulous application of a chest tube. In contrast, the module "Thoracocentesis" discusses a basic thoracocentesis. All students attended a lecture regarding chest tube insertion (regular curriculum) and afterwards received a Touch Surgery training lesson: intervention group used the module chest tube insertion and the control group used Thoracocentesis as control training. Participants' performance in chest tube insertion on a porcine model was rated on-site via blinded face-to-face rating and via video recordings using a modified OSATS tool. Afterwards, every participant received an individual questionnaire for self-evaluation. Here, trainees gave information about their individual training level, as well as previous experiences, gender, and hobbies. Primary end point was operative performance during chest tube insertion by direct observance. A total of 183 students enrolled, 116 students participated (63.4%), and 21 were excluded because of previous experiences in chest tube insertion. Students were randomized to the intervention group (49/95, 52%) and control group (46/95, 48%). The intervention group performed significantly better than the control group (Intervention group: 38.0 [I 50 =7.0] points; control group: 30.5 [I 50 =8.0] points; P<.001). The intervention group showed significantly improved economy of time and motion (P=.004), needed significantly less help (P<.001), and was more confident in handling of instruments (P<.001) than the control group. The results from this study show that serious games are a valid and effective tool in education of operative performance in chest tube insertion. We believe that serious games should be implemented in the surgical curriculum, as well as residency programs, in addition to traditional learning methods. German Clinical Trials Register (DRKS) DRKS00009994; https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00009994 (Archived by Webcite at http://www.webcitation.org/6ytWF1CWg). ©Patrick Haubruck, Felix Nickel, Julian Ober, Tilman Walker, Christian Bergdolt, Mirco Friedrich, Beat Peter Müller-Stich, Franziska Forchheim, Christian Fischer, Gerhard Schmidmaier, Michael C Tanner. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 21.05.2018.
Bacteriology of urinary tract infection associated with indwelling J ureteral stents.
Kehinde, Elijah O; Rotimi, Vincent O; Al-Hunayan, Adel; Abdul-Halim, Hamdy; Boland, Fareeda; Al-Awadi, Khaleel A
2004-11-01
To investigate the microorganisms responsible for urinary tract infection (UTI) and stent colonization in patients with indwelling J ureteral stents and to compare the antimicrobial susceptibility pattern of the isolates from urine and J stents in order to establish the etiologic agents of bacteriuria and colonized stents in such patients and provide baseline data on an antibiotic policy for the urology unit. Midstream urine from 250 patients requiring J stent insertion was investigated microbiologically prior to stent insertion and on the day of stent removal. After stent removal, 3 to 5 cm of the tip located in the bladder was also sent for culture. Patients' bio-data and underlying diseases were documented. Those with no known systemic diseases ("normal patients") were also studied as controls. Of the 250 patients studied, 152 (61%) were normal, while 27 (11%), 53 (21%), and 18 (7%) had diabetes mellitus (DM), chronic renal failure (CRF), and diabetic nephropathy (DN), respectively. The mean duration of stent retention was 27 days. All microbial isolates were tested for their susceptibility to a panel of 10 antibiotics. Twelve patients (5%) before stent insertion and 42 patients (17%; P < 0.001) on the day of stent removal had positive urine cultures. One hundred four stents (42%) were culture positive. Of the 104 patients with positive stent cultures, in 62 patients (60%), urine culture was sterile. The commonest isolates were Escherichia coli, Enterococcus spp., Staphylococcus spp., Pseudomonas, and Candida spp. On the day of stent removal, urine culture was positive in 28% of the normal patients compared with 57% (P = 0.11), 78% (P < 0.001), and 62% (P < 0.001) of patients with CRF, DM, and DN, respectively. Stent isolates were more resistant to antibiotics than the organism isolated before stent insertion. An indwelling J ureteral stent carries a significant risk of bacteriuria and stent colonization. The sensitivity of urine culture to stent colonization is low, and therefore, a negative culture does not rule out a colonized stent. Bacteria cultured from urine after stent insertion and from the stents are more resistant to antibiotics than are those cultured from urine before stent insertion. Norfloxacin or ciprofloxacin is recommended as prophylaxis prior to stent insertion, and an aminoglycoside can be added to treat symptomatic patients with severe infections.
Viana Taveira, Michelle Ribeiro; Lima, Luciana Santana; de Araújo, Cláudia Corrêa; de Mello, Maria Júlia Gonçalves
2017-02-01
Totally implantable venous access ports (TIVAPs) are used for prolonged central venous access, allowing the infusion of chemotherapy and other fluids and improving the quality of life of children with cancer. TIVAPs were developed to reduce the infection rates associated with central venous catheters; however, infectious events remain common and have not been fully investigated in pediatric oncology patients. A retrospective cohort was formed to investigate risk factors for central line-associated bloodstream infection (CLABSI) in pediatric cancer patients. Sociodemographic, clinical, and TIVAP insertion-related variables were evaluated, with the endpoint being the first CLABSI. A Kaplan-Meier analysis was performed to determine CLABSI-free catheter survival. Overall, 188 children were evaluated over 77,541 catheter days, with 94 being diagnosed with CLABSI (50%). Although coagulase-negative staphylococci were the pathogens most commonly isolated, Gram-negative microorganisms (46.8%) were also prevalent. In the multivariate analysis, factors that increased the risk for CLABSI were TIVAP insertion prior to chemotherapy (risk ratio [RR] = 1.56; P < 0.01), white blood cell count less than 1,000 mm -3 on the day of implantation (RR = 1.64; P < 0.01), and chronic malnutrition (RR = 1.41; P < 0.05). Median time without CLABSI following TIVAP insertion was 74.5 days. Risk factors for CLABSI in pediatric cancer patients with a TIVAP may be related to the severity of the child's condition at catheter insertion. Insertion of the catheter before chemotherapy and unfavorable conditions such as malnutrition and bone marrow aplasia can increase the risk of CLABSI. Protocols must be revised and surveillance increased over the first 10 weeks of treatment. © 2016 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Reynolds, Ralph E.; And Others
1979-01-01
College students read a text either with or without inserted questions. Question groups performed better, relative to controls, on post-test items that repeated inserted questions, and on new post-test items from the same categories as the inserted questions. A selective attention interpretation of the effect of inserted questions was made.…
Keller, Marla J.; Buckley, Niall; Katzen, Lauren L.; Walsh, Jennifer; Friedland, Barbara; Littlefield, Sarah; Lin, Juan; Xue, Xiaonan; Cornelison, Terri; Herold, Betsy C.; Einstein, Mark H.
2014-01-01
Background Applicator dye staining and ultraviolet (UV) light have been used in trials to measure adherence, but not in the setting of before and after sex gel dosing (BAT-24). This study was designed to determine if semen or pre-sex gel dosing impacts the sensitivity and specificity of a dye stain assay (DSA) for measuring vaginal insertion of placebo-filled applicators with BAT-24 dosing. Methods Healthy monogamous couples received Microlax®-type applicators filled with hydroxyethylcelluose placebo gel. Women were instructed to vaginally insert one dose of gel before and a second dose after sex and to return applicators within 48 hours after sex. Applicators were stained to detect semen followed by UV then DSA and scored by two readers. Positive and negative controls were randomly included in applicator batches. Results Fifteen couples completed the study. Each female returned at least six applicators over a 30-day period. The sensitivity for insertion of post-sex applicators was higher for UV (97%) compared to DSA (90%) and the specificity was similar (≥96%). For pre-sex applicators, the sensitivity and specificity were higher for DSA (100%) compared to UV testing (87% sensitivity, 96% specificity). Among returned post-sex applicators, 95% tested positive by UV compared to 87% by DSA. Agreement between readers was significantly better on the pre-sex applicators for DSA than for UV and for post-sex readings agreement was less than half that for UV, although the results were not statistically significant. Conclusions Applicator tests are feasible for measuring adherence in trials with gel dosing before and after sex. PMID:24220355
Comparison of the shock absorption capacities of different mouthguards.
Bochnig, Melina Simonetta; Oh, Min-Jung; Nagel, Theresa; Ziegler, Fred; Jost-Brinkmann, Paul-Georg
2017-06-01
In this in vitro study, the protective qualities of different mouthguard types were examined during small hard object collisions. The aim was to investigate inconclusive aspects of hard inserts, nylon nets, and air spaces as reinforcements in the anterior region and the protection qualities of ethylene vinyl acetate (EVA). Five different mouthguards with a labial thickness between 2 mm and 11 mm made of materials of varying stiffness were investigated. As a negative control, the same experiments were performed without a mouthguard. Different combinations of EVA and labial inserts ((polyethylene terephthalate glycol-modified [PETG]), nylon mesh, air space) were tested. Using a stainless steel pendulum device, blows of different energy (0.07-2.85 joules) were applied to the center of the crown of a pivoted tooth in a custom-built jaw model. A laser Doppler vibrometer measured the tooth deflection, while an acceleration sensor attached to the pendulum measured the braking accelerations. Tooth deflection was reduced up to 99.7% compared to no mouthguard, and the braking acceleration was reduced up to 72.2% by increasing the mouthguards' labial thickness in combination with labial inserts of different stiffness and a built-in air space between the front teeth and the mouthguard. The mouthguards made of soft materials (EVA with nylon mesh) showed slightly better protection qualities than the more rigid mouthguards of similar thickness (PETG; P<.05). However, with increasing impact energy, their protective capacities decreased to a greater extent than the stiffer mouthguards. The combination of increased labial thickness and labial inserts of varying stiffness and eventually an air space offers the best protection capacities for hard, small object collisions. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Luo, Zhoujie; Gao, Ya; Zhu, Tong; Zhang, John Zenghui; Xia, Fei
2017-08-31
Water molecules can serve as proton shuttles for proton transfer in the C-H bond insertion reactions catalyzed by transition metal complexes. Recently, the control experiments performed for C-H bond insertion of phenol and anisol by gold carbenes show that large discrepancy exists in the yields of hydrogenated and deuterated products. Thus, we conducted a detailed theoretical analysis on the function of water molecules in the C-H bond insertion reactions. The comparison of calculated results and control experiments indicates that the solution water molecules play a crucial role of proton shuttle in C-H bond insertion. In particular, it was found that the hydroxyl groups in phenols were capable of donating protons via water shuttles for the production of C-H products, which had a substantial influence on the yields of inserted products. The hydroxyl groups instead of C-H bonds in phenols function like "proton reservoirs" in the C-H bond insertion, which we call the "proton self-sufficient" (PSS) function of phenol. The PSS function of phenol indicates that the substrates with and without proton reservoirs will lead to different C-H bond insertion products.
Bertoti, D B; Gross, A L
1988-07-01
Biofeedback devices have been used successfully to improve head control and symmetrical standing in children with cerebral palsy. This clinical report describes a biofeedback seat insert developed to improve erect sitting posture in children with cerebral palsy who have inadequate trunk control. The seat insert is easily placed against the back of any seating device. A momentary-contact pressure switch on the seat insert is activated when the child exerts pressure on it by extending his trunk. The pressure switch then activates a videocassette recorder or can be adapted to activate a television or radio. Five children with spastic cerebral palsy participated in this evaluation of the biofeedback seat insert. The results of this evaluation show that the children used the biofeedback seat insert effectively to actively improve their sitting posture by voluntarily extending their trunk against the pressure switch. The biofeedback seat insert offers physical therapists a valuable therapeutic training tool to encourage carry-over of improved sitting posture away from the clinical setting for children with cerebral palsy.
48 CFR 337.103-70 - Solicitation provisions and contract clauses.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 1994. (b) The Contracting Officer shall insert the clause in 352.237-71, Crime Control Act—Reporting of... specified in the Crime Control Act of 1990, including, but not limited to, physicians, nurses, dentists... drivers. (c) The Contracting Officer shall insert the clause in 352.237-72, Crime Control Act—Requirement...
Elmerstig, Eva; Thomtén, Johanna
2016-11-16
This study examines associations between the first experience of vaginal intercourse/tampon insertion and later experiences of vulvar pain. The study is based on questionnaire data from 1,259 Swedish female senior high-school students, aged 18 to 22 years old. Of these, 592 women reported present vulvar pain. Present vulvar pain was associated with first-time experiences of vaginal intercourse (pain, negative experience, against will) and with pain at tampon insertion. First-time experiences were also related to temporal aspects of present vulvar pain during vaginal intercourse (at the beginning, after a while during, and after). Implications of first-time experiences of vaginal intercourse for future symptoms of vulvar pain are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krempasky, J.; Flechsig, U.; Korhonen, T.
Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a 'master' controlling the undulator 'slave' energy position. This master-slave software implementation exploits EPICS distributed device control over computer network andmore » allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.« less
Degidi, Marco; Daprile, Giuseppe; Piattelli, Adriano
The aims of this study were to evaluate the ability of a stepped osteotomy to improve dental implant primary stability in low-density bone sites and to investigate possible correlations between primary stability parameters. The study was performed on fresh humid bovine bone classified as type III. The test group consisted of 30 Astra Tech EV implants inserted following the protocol provided by the manufacturer. The first control group consisted of 30 Astra Tech EV implants inserted in sites without the underpreparation of the apical portion. The second control group consisted of 30 Astra Tech TX implants inserted following the protocol provided by the manufacturer. Implant insertion was performed at the predetermined 30 rpm. The insertion torque data were recorded and exported as a curve; using a trapezoidal integration technique, the area underlying the curve was calculated: this area represents the variable torque work (VTW). Peak insertion torque (pIT) and resonance frequency analysis (RFA) were also recorded. A Mann-Whitney test showed that the mean VTW was significantly higher in the test group compared with the first control and second control groups; furthermore, statistical analysis showed that pIT also was significantly higher in the test group compared with the first and second control groups. Analyzing RFA values, only the difference between the test group and second control group showed statistical significance. Pearson correlation analysis showed a very strong positive correlation between pIT and VTW values in all groups; furthermore, it showed a positive correlation between pIT and RFA values and between VTW and RFA values only in the test group. Within the limitations of an in vitro study, the results show that stepped osteotomy can be a viable method to improve implant primary stability in low-density bone sites, and that, when a traditional osteotomy method is performed, RFA presents no correlation with pIT and VTW.
Linear motion device and method for inserting and withdrawing control rods
Smith, J.E.
Disclosed is a linear motion device and more specifically a control rod drive mechanism (CRDM) for inserting and withdrawing control rods into a reactor core. The CRDM and method disclosed is capable of independently and sequentially positioning two sets of control rods with a single motor stator and rotor. The CRDM disclosed can control more than one control rod lead screw without incurring a substantial increase in the size of the mechanism.
Characterization of ROP18 alleles in human toxoplasmosis.
Sánchez, Víctor; de-la-Torre, Alejandra; Gómez-Marín, Jorge Enrique
2014-04-01
The role of the virulent gene ROP18 polymorphisms is not known in human toxoplasmosis. A total of 320 clinical samples were analyzed. In samples positive for ROP18 gene, we determined by an allele specific PCR, if patients got the upstream insertion positive ROP18 sequence Toxoplasma strain (mouse avirulent strain) or the upstream insertion negative ROP18 sequence Toxoplasma strain (mouse virulent strain). We designed an ELISA assay for antibodies against ROP18 derived peptides from the three major clonal lineages of Toxoplasma. 20 clinical samples were of quality for ROP18 allele analysis. In patients with ocular toxoplasmosis, a higher inflammatory reaction on eye was associated to a PCR negative result for the upstream region of ROP18. 23.3%, 33% and 16.6% of serums from individuals with ocular toxoplasmosis were positive for type I, type II and type III ROP18 derived peptides, respectively but this assay was affected by cross reaction. The absence of Toxoplasma ROP18 promoter insertion sequence in ocular toxoplasmosis was correlated with severe ocular inflammatory response. Determination of antibodies against ROP18 protein was not useful for serotyping in human toxoplasmosis. © 2013.
Experimental analysis of robot-assisted needle insertion into porcine liver.
Wang, Wendong; Shi, Yikai; Goldenberg, Andrew A; Yuan, Xiaoqing; Zhang, Peng; He, Lijing; Zou, Yingjie
2015-01-01
How to improve placement accuracy of needle insertion into liver tissue is of paramount interest to physicians. A robot-assisted system was developed to experimentally demonstrate its advantages in needle insertion surgeries. Experiments of needle insertion into porcine liver tissue were performed with conic tip needle (diameter 8 mm) and bevel tip needle (diameter 1.5 mm) in this study. Manual operation was designed to compare the performance of the presented robot-assisted system. The real-time force curves show outstanding advantages of robot-assisted operation in improving the controllability and stability of needle insertion process by comparing manual operation. The statistics of maximum force and average force further demonstrates robot-assisted operation causes less oscillation. The difference of liver deformation created by manual operation and robot-assisted operation is very low, 1 mm for average deformation and 2 mm for maximum deformation. To conclude, the presented robot-assisted system can improve placement accuracy of needle by stably control insertion process.
Master-slave robotic system for needle indentation and insertion.
Shin, Jaehyun; Zhong, Yongmin; Gu, Chengfan
2017-12-01
Bilateral control of a master-slave robotic system is a challenging issue in robotic-assisted minimally invasive surgery. It requires the knowledge on contact interaction between a surgical (slave) robot and soft tissues. This paper presents a master-slave robotic system for needle indentation and insertion. This master-slave robotic system is able to characterize the contact interaction between the robotic needle and soft tissues. A bilateral controller is implemented using a linear motor for robotic needle indentation and insertion. A new nonlinear state observer is developed to online monitor the contact interaction with soft tissues. Experimental results demonstrate the efficacy of the proposed master-slave robotic system for robotic needle indentation and needle insertion.
DEMINERALIZER BUILDING, TRA608. INSTALLATION OF SAMPLING AND OTHER INSTRUMENTS COMPLETES ...
DEMINERALIZER BUILDING, TRA-608. INSTALLATION OF SAMPLING AND OTHER INSTRUMENTS COMPLETES DEMINERALIZER UNITS ALONG NORTH WALL. CAMERA FACES EAST. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION PRINTED ON THE ORIGINAL NEGATIVE. INL NEGATIVE NO. 3996A. Unknown Photographer, 12/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
MTR WING, TRA604. A LABORATORY ROOM WITH ITS CABINETS AND ...
MTR WING, TRA-604. A LABORATORY ROOM WITH ITS CABINETS AND SERVICE STRIP DOWN CENTER OF ROOM. CARD IN LEFT CORNER OF VIEW WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION PRINTED ON THE ORIGINAL NEGATIVE. INL NEGATIVE NO. 3817. Unknown Photographer, 11/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Flow monitoring and control system for injection wells
Corey, John C.
1993-01-01
A system for monitoring and controlling the injection rate of fluid by an injection well of an in-situ remediation system for treating a contaminated groundwater plume. The well is fitted with a gated insert, substantially coaxial with the injection well. A plurality of openings, some or all of which are equipped with fluid flow sensors and gates, are spaced along the insert. The gates and sensors are connected to a surface controller. The insert may extend throughout part of, or substantially the entire length of the injection well. Alternatively, the insert may comprise one or more movable modules which can be positioned wherever desired along the well. The gates are opened part-way at the start of treatment. The sensors monitor and display the flow rate of fluid passing through each opening on a controller. As treatment continues, the gates are opened to increase flow in regions of lesser flow, and closed to decrease flow in regions of greater flow, thereby approximately equalizing the amount of fluid reaching each part of the plume.
Flow monitoring and control system for injection wells
Corey, J.C.
1993-02-16
A system for monitoring and controlling the injection rate of fluid by an injection well of an in-situ remediation system for treating a contaminated groundwater plume. The well is fitted with a gated insert, substantially coaxial with the injection well. A plurality of openings, some or all of which are equipped with fluid flow sensors and gates, are spaced along the insert. The gates and sensors are connected to a surface controller. The insert may extend throughout part of, or substantially the entire length of the injection well. Alternatively, the insert may comprise one or more movable modules which can be positioned wherever desired along the well. The gates are opened part-way at the start of treatment. The sensors monitor and display the flow rate of fluid passing through each opening on a controller. As treatment continues, the gates are opened to increase flow in regions of lesser flow, and closed to decrease flow in regions of greater flow, thereby approximately equalizing the amount of fluid reaching each part of the plume.
Topical anesthesia for line insertion in very low birth weight infants.
Garcia, O C; Reichberg, S; Brion, L P; Schulman, M
1997-01-01
This pilot study was designed to assess the impact of topical lidocaine and prilocaine cream on the pain response of very low birth weight infants undergoing percutaneous central venous line insertion. Infants were randomly assigned to receive 1 to 1.25 gm of the topical anesthetic or to receive zinc oxide placebo 1 hour before line insertion. Investigators blinded to treatment group assignment obtained serial measurements of heart rate, respiratory rate, systolic blood pressure, and oxygen saturation by pulse oximetry. Toxicity from lidocaine was assessed by clinical parameters, and toxic effects from prilocaine were assessed by methemoglobin levels (normal range 0% to 4%). Hearts rates increased significantly during line insertion in controls (n = 6) but not in treated patients (n = 7). Respiratory rates and blood pressure values increased significantly during line insertion in both groups. Oxygen saturation did not change significantly in either group. The percent of increase in heart and respiratory rates from baseline was attenuated in the treated patients compared with controls. Methemoglobin levels were 0.3% to 2.0% for the treated group and 0.3% to 0.7% for controls. The topical lidocaine and prilocaine cream application attenuated the lability of vital signs during line insertion in very low birth weight infants, with no evidence of toxicity.
Kim, Sioh; Kim, Hyun-Jae; Yeo, Jin-Seok; Hong, Sung-Jung; Lee, Ji-Min; Jeon, Younghoon
2011-09-01
The purpose of this study was to investigate whether lavender oil aromatherapy can reduce the bispectral index (BIS) values and stress and decrease the pain of needle insertion in 30 volunteers. Thirty (30) healthy volunteers were randomly allocated to 2 groups: the experimental group received oxygen with a face mask coated with lavender oil for 5 minutes, and the control group received oxygen through a face mask with no lavender oil for 5 minutes. The stress level (0=no stress, 10=maximum stress), BIS value, and pain intensity of needle insertion (0=no pain, 10=worst pain imaginable) were measured. There were no significant differences in age, sex, height, and weight between the two groups. Stress level, BIS value, and pain intensity of needle insertion before aromatherapy were similar between the two groups. However, the stress values (p<0.001) and BIS value (p<0.001) after aromatherapy were significantly reduced compared with the control. In addition, the pain intensity of needle insertion was significantly decreased after aromatherapy compared with the control (p<0.001). Lavender aromatherapy in volunteers provided a significant decrease in the stress levels and in the BIS values. In addition, it significantly reduced the pain intensity of needle insertion.
Development of a reliable method to assess footwear comfort during running.
Mündermann, Anne; Nigg, Benno M; Stefanyshyn, Darren J; Humble, R Neil
2002-08-01
The purposes of this study were: (a) to determine whether subjects are able to distinguish between differences in footwear with respect to footwear comfort; and (b) to determine how reliably footwear comfort can be assessed using a visual analogue scale (VAS) and a protocol including a control condition during running. Intraclass correlation coefficients (ICCs) between comfort ratings for repeated conditions were high (ICC = 0.799). Differences in comfort ratings between the insert conditions were significant. A paired t-test revealed a significant difference in overall comfort ratings for the control insert when tested after the soft insert compared to when tested after the hard insert (P = 0.008). The results of this study showed that VASs provide a reliable measure to assess footwear comfort during running under the conditions that: (a) a control condition is included; and (b) the average comfort rating of sessions 4-6 is used. Copyright 2002 Elsevier Science B.V.
Torsional Dynamics of Steerable Needles: Modeling and Fluoroscopic Guidance
Swensen, John P.; Lin, MingDe; Okamura, Allison M.; Cowan, Noah J.
2017-01-01
Needle insertions underlie a diversity of medical interventions. Steerable needles provide a means by which to enhance existing needle-based interventions and facilitate new ones. Tip-steerable needles follow a curved path and can be steered by twisting the needle base during insertion, but this twisting excites torsional dynamics that introduce a discrepancy between the base and tip twist angles. Here, we model the torsional dynamics of a flexible rod—such as a tip-steerable needle—during subsurface insertion and develop a new controller based on the model. The torsional model incorporates time-varying mode shapes to capture the changing boundary conditions inherent during insertion. Numerical simulations and physical experiments using two distinct setups—stereo camera feedback in semi-transparent artificial tissue and feedback control with real-time X-ray imaging in optically opaque artificial tissue— demonstrate the need to account for torsional dynamics in control of the needle tip. PMID:24860026
Robert, Marc-André; Lytvyn, Viktoria; Deforet, Francis; Gilbert, Rénald; Gaillet, Bruno
2017-01-01
Virus-like particles (VLPs) derived from retroviruses and lentiviruses can be used to deliver recombinant proteins without the fear of causing insertional mutagenesis to the host cell genome. In this study we evaluate the potential of an inducible lentiviral vector packaging cell line for VLP production. The Gag gene from HIV-1 was fused to a gene encoding a selected protein and it was transfected into the packaging cells. Three proteins served as model: the green fluorescent protein and two transcription factors-the cumate transactivator (cTA) of the inducible CR5 promoter and the human Krüppel-like factor 4 (KLF4). The sizes of the VLPs were 120-150 nm in diameter and they were resistant to freeze/thaw cycles. Protein delivery by the VLPs reached up to 100% efficacy in human cells and was well tolerated. Gag-cTA triggered up to 1100-fold gene activation of the reporter gene in comparison to the negative control. Protein engineering was required to detect Gag-KLF4 activity. Thus, insertion of the VP16 transactivation domain increased the activity of the VLPs by eightfold. An additional 2.4-fold enhancement was obtained by inserting nuclear export signal. In conclusion, our platform produced VLPs capable of efficient protein transfer, and it was shown that protein engineering can be used to improve the activity of the delivered proteins as well as VLP production.
Kuang, Jiayi; Li, Yuxuan; He, Yufeng; Gan, Lin; Wang, Aiming; Chen, Yanhua; Li, Xiaoting; Guo, Lin; Tang, Rongjun
2016-04-01
To compare the effects of oblique insertion at anatomical points and conventional acupuncture for sacroiliac joint injury. Eighty patients were randomly divided into an observation group and a control group, 40 cases in each one. In the observation group, oblique insertion therapy at anatomical points was used, and the 9 points of equal division (anatomical points) marked by palpating the anatomical symbol were treated as the insertion acupoints. In the control group, conventional acupuncture was applied, and perpendicular insertion was adopted at Huantiao (GB 30), Zhibian (BL 54) and Weizhong (BL 40), etc. In the two groups, the! treatment was given once a day and 5 times per week. Ten treatments were made into one course and two courses were required. The clinical effects, the changes of visual analogue scale (VAS) and Oswestry dysfunctional index. (ODI) before and after treatment were observed in the two groups. The total effective rate of the observation group was 90.0% (36/40), which was better than 72.5% (29/40) of the control group (P < 0.05). After treatment, the results of the VAS and ODI of the two groups were apparently declined (both P < 0.01), and those in the observation group were decreased more obviously (both P < 0.01). The effect of oblique inser-tion at anatomical points for sacroiliac joint injury is superior to that of conventional acupuncture, which can effectively relieve pain and improve the disfunction.
2011-01-01
We examined change of Runx2 and ALP expression in mouse tooth pulp which exposed to teeth separation experiment by immunohistochemistry as a model for conservative dentistry treatment. 8-week-old 36 male ddY mice were used and wedge was inserted between upper 1st and 2nd molars. The wedge was removed 30 minutes as well as 3 hours after the insertion and the samples were prepared extending up to 1 week of time period for regular histopathological and immunohistochemical examinations for ALP and Runx2 expression. The opposite sides without wedge insertion were taken as controls. In the control group pulp, weak expressions of Runx2 and ALP in the vessel endothelial cells as well as the pulp cells were revealed, suggesting the appearance of these genes upon mechanical stress induced by mastication and tongue pressure etc. On the other hand in the experiment group, Runx2 expression increased both in 30-minute and 3-hour teeth separation group. The expression became maximum at 24 hours. Then it gradually decreased and became similar level with the control group at 1-week after the wedge insertion. Similarly ALP expression increased after the wedge insertion and was maximum at 24 hours and then gradually decreased to the levels similar with the control group. These results suggest that when immunohistochemical expression of Runx2 as well as ALP was used as an index, no severe damage occur upon clinical application of wedge insertion. PMID:22027645
A Mechanical Coil Insertion System for Endovascular Coil Embolization of Intracranial Aneurysms
Haraguchi, K.; Miyachi, S.; Matsubara, N.; Nagano, Y.; Yamada, H.; Marui, N.; Sano, A.; Fujimoto, H.; Izumi, T.; Yamanouchi, T.; Asai, T.; Wakabayashi, T.
2013-01-01
Summary Like other fields of medicine, robotics and mechanization might be introduced into endovascular coil embolization of intracranial aneurysms for effective treatment. We have already reported that coil insertion force could be smaller and more stable when the coil delivery wire is driven mechanically at a constant speed. Another background is the difficulty in synchronizing operators' minds and hands when two operators control the microcatheter and the coil respectively. We have therefore developed a mechanical coil insertion system enabling a single operator to insert coils at a fixed speed while controlling the microcatheter. Using our new system, the operator manipulated the microcatheter with both hands and drove the coil using foot switches simultaneously. A delivery wire force sensor previously reported was used concurrently, allowing the operator to detect excessive stress on the wire. In vitro coil embolization was performed using three methods: simple mechanical advance of the coil; simple mechanical advance of the coil with microcatheter control; and driving (forward and backward) of the coil using foot switches in addition to microcatheter control. The system worked without any problems, and did not interfere with any procedures. In experimental coil embolization, delivery wire control using the foot switches as well as microcatheter manipulation helped to achieve successful insertion of coils. This system could offer the possibility of developing safer and more efficient coil embolization. Although we aim at total mechanization and automation of procedures in the future, microcatheter manipulation and synchronized delivery wire control are still indispensable using this system. PMID:23693038
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-23
... of showerhead and hand-held showerhead; removal of body sprays from the proposed showerhead... standardized test method to be used when verifying the mechanical retention of a showerhead flow control insert... Faucets 1. Definitions 2. Test Procedure for Showerhead Flow Control Insert [[Page 62971
Mutsuzaki, Hirotaka; Nakajima, Hiromi; Sakane, Masataka
2018-01-01
[Purpose] To investigate the influence of knee immobilization period on recovery of histological damages in the anterior cruciate ligament (ACL) insertion and articular cartilage in rabbits. This knowledge is important for determining the appropriate rehabilitation approach for patients with ligament injuries, fracture, disuse atrophy, and degenerative joint disease. [Materials and Methods] Forty-eight male Japanese white rabbits were divided equally into the remobilization and control groups. The remobilization group had the right knee surgically immobilized, and was divided equally into four subgroups according to the duration of immobilization (1, 2, 4 and 8 weeks). After the immobilization was removed, the rabbits moved freely for 8 weeks. The control group underwent sham operation and followed the same time course as the remobilization group. The chondrocyte apoptosis rate and chondrocyte proliferation rate in the ACL insertion and articular cartilage were analyzed after remobilization. [Results] In the ACL insertion, the remobilization group had a higher chondrocyte apoptosis rate than the control group after 8 weeks of immobilization, and a lower chondrocyte proliferation rate than the control group after 4 and 8 weeks of immobilization. In the articular cartilage, the remobilization group had a lower chondrocyte proliferation rate than the control group after 8 weeks of immobilization. After 8 weeks of remobilization, the ACL insertion and articular cartilage are not completely recovered after 4 and 8 weeks of immobilization, respectively. [Conclusion] Our results suggest that 8 weeks of remobilization will result in recovery of the ACL insertion after 2 weeks of knee immobilization, and recovery of the articular cartilage after 4 weeks of knee immobilization. If 8 weeks of immobilization occurs, a remobilization duration of more than 8 weeks may be necessary.
Insertion of Vertically Aligned Nanowires into Living Cells by Inkjet Printing of Cells.
Lee, Donggyu; Lee, Daehee; Won, Yulim; Hong, Hyeonaug; Kim, Yongjae; Song, Hyunwoo; Pyun, Jae-Chul; Cho, Yong Soo; Ryu, Wonhyoung; Moon, Jooho
2016-03-01
Effective insertion of vertically aligned nanowires (NWs) into cells is critical for bioelectrical and biochemical devices, biological delivery systems, and photosynthetic bioenergy harvesting. However, accurate insertion of NWs into living cells using scalable processes has not yet been achieved. Here, NWs are inserted into living Chlamydomonas reinhardtii cells (Chlamy cells) via inkjet printing of the Chlamy cells, representing a low-cost and large-scale method for inserting NWs into living cells. Jetting conditions and printable bioink composed of living Chlamy cells are optimized to achieve stable jetting and precise ink deposition of bioink for indentation of NWs into Chlamy cells. Fluorescence confocal microscopy is used to verify the viability of Chlamy cells after inkjet printing. Simple mechanical considerations of the cell membrane and droplet kinetics are developed to control the jetting force to allow penetration of the NWs into cells. The results suggest that inkjet printing is an effective, controllable tool for stable insertion of NWs into cells with economic and scale-related advantages. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sound Absorption of a 2DOF Resonant Liner with Negative Bias Flow
NASA Technical Reports Server (NTRS)
Ahuja, K. K.; Cataldi, P.; Gaeta, R. J., Jr.
2000-01-01
This report describes an experimental study conducted to determine the effect of negative bias flow on the sound absorption of a two degree-of-freedom liner. The backwall for the liner was designed to act as a double-Helmholtz resonator so as to act as a hard wall at all frequencies except at its resonant frequencies. The effect of bias flow is investigated for a buried septum porosity of 2% and 19.5% for bias flow orifice Mach numbers up to 0.311. The bias flow appears to modify the resistance and reactance of the backwall alone at lower frequencies up to about 2 kHz, with marginal effects at higher frequencies. Absorption coefficients close to unity are achieved for a frequency range of 500 - 4000 Hz for the overall liner for a septum porosity of 2% and orifice Mach number of 0.128. Insertion loss tests performed in a flow duct facility for grazing flow Mach numbers up to 0.2 and septum Mach numbers up to 0.15 showed that negative bias flow can increase insertion loss by as much as 10 dB at frequencies in the range of 500 D 1400 Hz compared to no grazing flow. The effectiveness of the negative bias flow is diminished as the grazing flow velocity is increased.
Modeling of laser welding of steel and titanium plates with a composite insert
NASA Astrophysics Data System (ADS)
Isaev, V. I.; Cherepanov, A. N.; Shapeev, V. P.
2017-10-01
A 3D model of laser welding proposed before by the authors was extended to the case of welding of metallic plates made of dissimilar materials with a composite multilayer intermediate insert. The model simulates heat transfer in the welded plates and takes into account phase transitions. It was proposed to select the composition of several metals and dimensions of the insert to avoid the formation of brittle intermetallic phases in the weld joint negatively affecting its strength properties. The model accounts for key physical phenomena occurring during the complex process of laser welding. It is capable to calculate temperature regimes at each point of the plates. The model can be used to select the welding parameters reducing the risk of formation of intermetallic plates. It can forecast the dimensions and crystalline structure of the solidified melt. Based on the proposed model a numerical algorithm was constructed. Simulations were carried out for the welding of titanium and steel plates with a composite insert comprising four different metals: copper and niobium (intermediate plates) with steel and titanium (outer plates). The insert is produced by explosion welding. Temperature fields and the processes of melting, evaporation, and solidification were studied.
Xie, Yu; Liu, Shuang; Sun, Dong
2018-01-01
Robot-assisted surgery is of growing interest in the surgical and engineering communities. The use of robots allows surgery to be performed with precision using smaller instruments and incisions, resulting in shorter healing times. However, using current technology, an operator cannot directly feel the operation because the surgeon-instrument and instrument-tissue interaction force feedbacks are lost during needle insertion. Advancements in force feedback and control not only help reduce tissue deformation and needle deflection but also provide the surgeon with better control over the surgical instruments. The goal of this review is to summarize the key components surrounding the force feedback and control during robot-assisted needle insertion. The literature search was conducted during the middle months of 2017 using mainstream academic search engines with a combination of keywords relevant to the field. In total, 166 articles with valuable contents were analyzed and grouped into five related topics. This survey systemically summarizes the state-of-the-art force control technologies for robot-assisted needle insertion, such as force modeling, measurement, the factors that influence the interaction force, parameter identification, and force control algorithms. All studies show force control is still at its initial stage. The influence factors, needle deflection or planning remain open for investigation in future. PMID:29439539
Yang, Chongjun; Xie, Yu; Liu, Shuang; Sun, Dong
2018-02-12
Robot-assisted surgery is of growing interest in the surgical and engineering communities. The use of robots allows surgery to be performed with precision using smaller instruments and incisions, resulting in shorter healing times. However, using current technology, an operator cannot directly feel the operation because the surgeon-instrument and instrument-tissue interaction force feedbacks are lost during needle insertion. Advancements in force feedback and control not only help reduce tissue deformation and needle deflection but also provide the surgeon with better control over the surgical instruments. The goal of this review is to summarize the key components surrounding the force feedback and control during robot-assisted needle insertion. The literature search was conducted during the middle months of 2017 using mainstream academic search engines with a combination of keywords relevant to the field. In total, 166 articles with valuable contents were analyzed and grouped into five related topics. This survey systemically summarizes the state-of-the-art force control technologies for robot-assisted needle insertion, such as force modeling, measurement, the factors that influence the interaction force, parameter identification, and force control algorithms. All studies show force control is still at its initial stage. The influence factors, needle deflection or planning remain open for investigation in future.
Smillie, Ian; Robertson, Sophie; Yule, Anna; Wynne, David M; Russell, Craig J H
2014-10-01
Optimizing hearing in patients with cleft lip and/or palate (CLP) by early recognition and management of otitis media with effusion is essential for speech development. Some evidence has suggested higher complication rates from ventilation tube (VT) insertion in patients with CLP and has led to a trend not to treat these patients surgically. However, studies have failed to match comparison groups for age and sex. To compare complication rates from VT insertion in pediatric patients with and without CLP. The study used a nested case-control design to evaluate 60 pediatric patients with CLP who underwent VT insertion at a children's hospital. The control group of age- and sex-matched patients was selected from a database of 2943 VT insertions. All patients were administered general anesthesia and underwent VT insertion by a pediatric otorhinolaryngology (ENT) team. The primary outcomes were numbers of otorrhea complications. Secondarily, rates of attendance at an ENT clinic specifically for complications were evaluated. Finally, numbers of complications other than otorrhea were assessed but not statistically analyzed owing to the varied types and low numbers in each group. The control cohort had 151 documented cases of otorrhea compared with 121 in the CLP group (ratio 1.25:1); the difference between groups was not statistically significant (P = .52). There was no significant difference in mean ENT clinic visits per patient for complications between groups (0.80 in the CLP group, 0.78 for controls) (P = .66). Regarding complications other than otorrhea, the control group reported more than the CLP group (43 vs 25; ratio, 1.7:1). Complication rates of VT placement among patients with CLP were not higher than those among patients without CLP. Therefore, treatment with VT insertion should be administered to patients with CLP under the same guidelines as for those without CLP. Indeed, there could be an argument for a shift in practice toward more aggressive treatment of patients with CLP, who are already vulnerable to speech and social developmental delay.
The structure of graphene oxide membranes in liquid water, ethanol and water-ethanol mixtures
NASA Astrophysics Data System (ADS)
Talyzin, Alexandr V.; Hausmaninger, Tomas; You, Shujie; Szabó, Tamás
2013-12-01
The structure of graphene oxide (GO) membranes was studied in situ in liquid solvents using synchrotron radiation X-ray diffraction in a broad temperature interval. GO membranes are hydrated by water similarly to precursor graphite oxide powders but intercalation of alcohols is strongly hindered, which explains why the GO membranes are permeated by water and not by ethanol. Insertion of ethanol into the membrane structure is limited to only one monolayer in the whole studied temperature range, in contrast to precursor graphite oxide powders, which are intercalated with up to two ethanol monolayers (Brodie) and four ethanol monolayers (Hummers). As a result, GO membranes demonstrate the absence of ``negative thermal expansion'' and phase transitions connected to insertion/de-insertion of alcohols upon temperature variations reported earlier for graphite oxide powders. Therefore, GO membranes are a distinct type of material with unique solvation properties compared to parent graphite oxides even if they are composed of the same graphene oxide flakes.The structure of graphene oxide (GO) membranes was studied in situ in liquid solvents using synchrotron radiation X-ray diffraction in a broad temperature interval. GO membranes are hydrated by water similarly to precursor graphite oxide powders but intercalation of alcohols is strongly hindered, which explains why the GO membranes are permeated by water and not by ethanol. Insertion of ethanol into the membrane structure is limited to only one monolayer in the whole studied temperature range, in contrast to precursor graphite oxide powders, which are intercalated with up to two ethanol monolayers (Brodie) and four ethanol monolayers (Hummers). As a result, GO membranes demonstrate the absence of ``negative thermal expansion'' and phase transitions connected to insertion/de-insertion of alcohols upon temperature variations reported earlier for graphite oxide powders. Therefore, GO membranes are a distinct type of material with unique solvation properties compared to parent graphite oxides even if they are composed of the same graphene oxide flakes. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr04631a
Karabayirli, Safinaz; Ayrim, Aylin Aker; Muslu, Bunyamin
2012-01-01
To compare the analgesic efficacy of oral tramadol and naproxen sodium on pain during insertion of an intrauterine device (IUD). Randomized, double-blinded, clinical trial (Canadian Task Force classification I). University-affiliated hospital. Single-center. One hundred three patients scheduled for insertion of an IUD. Patients were randomly assigned to receive oral tramadol 50 mg capsules (n = 35) or naproxen sodium 550 mg tablets (n = 34) or placebo (n = 34) 1 hour before insertion of the IUD. After insertion of the IUD, pain intensity was evaluated using a visual analog scale (VAS, 0-10). Adverse effects, patient satisfaction with the medication, and preference for using it during future insertions were also recorded. The VAS scores were significantly different during IUD insertion among the 3 groups (p = .001). Pain scores in the tramadol group were significantly lower than in the naproxen group (p = .003), and the scores in the naproxen group was significantly lower than in the control group (p = .001). Patient satisfaction with the medication and preference for its future use were significantly lower in the control group than in the other 2 groups (p = .001). Prophylactic analgesia using 50 mg tramadol and 550 mg naproxen, delivered orally, can be used to relieve pain during IUD insertion. However, tramadol capsules were found to be more effective than naproxen tablets. Copyright © 2012 AAGL. Published by Elsevier Inc. All rights reserved.
Youssef, J A; McKinley, T O; Yerby, S A; McLain, R F
1999-06-01
A bending analysis of pedicle screws inserted into vertebral body analogues. Intravertebral and intrapedicular pedicle screw bending moments were studied as a function of sagittal insertion angle. To determine how the pedicle screw bending moment is affected by changes in the insertion angle. There is a significant incidence of failure when pedicle screws are used to instrument unstable spinal segments. Extrinsic factors that affect screw bending failure have been poorly characterized. Previous work has demonstrated that intrapedicular pedicle screw bending moments are significantly affected by the sagittal location and depth of pedicle screw placement. Pedicle screw transducers were inserted in analogue vertebrae at one of three orientations: 7 degrees cephalad (toward the superior endplate), 7 degrees caudal (toward the inferior endplate), or parallel to the superior endplate (control). An axial load was applied to the superior endplate of the vertebra, and screw bending moments were recorded directly from the transducers. Screws angled 7 degrees cephalad developed significantly greater mean intrapedicular bending moments compared with screws inserted caudal or control screws. There was no significant difference in bending moments realized within the vertebral body for the three screw positions. Angulating pedicle screws toward the superior endplate increased bending moments within the pedicle. If attention to optimal screw insertion technique can reduce bending moments and potential for screw failure without increasing morbidity, surgical risk, or operative time, then proper insertion technique takes on new importance.
Sensitivity and specificity of eustachian tube function tests in adults.
Doyle, William J; Swarts, J Douglas; Banks, Julianne; Casselbrant, Margaretha L; Mandel, Ellen M; Alper, Cuneyt M
2013-07-01
The study demonstrates the utility of eustachian tube (ET) function (ETF) test results for accurately assigning ears to disease state. To determine if ETF tests can identify ears with physician-diagnosed ET dysfunction (ETD) in a mixed population at high sensitivity and specificity and to define the interrelatedness of ETF test parameters. Through use of the forced-response, inflation-deflation, Valsalva, and sniffing tests, ETF was evaluated in 15 control ears of adult subjects after unilateral myringotomy (group 1) and in 23 ears of 19 adult subjects with ventilation tubes inserted for ETD (group 2). Data were analyzed using logistic regression including each parameter independently and then a step-down discriminant analysis including all ETF test parameters to predict group assignment. Factor analysis operating over all parameters was used to explore relatedness. ETF testing. ETF parameters for the forced response, inflation-deflation, Valsalva, and sniffing tests measured in 15 control ears of adult subjects after unilateral myringotomy (group 1) and in 23 ears of 19 adult subjects with ventilation tubes inserted for ETD (group 2). The discriminant analysis identified 4 ETF test parameters (Valsalva, ET opening pressure, dilatory efficiency, and percentage of positive pressure equilibrated) that together correctly assigned ears to group 2 at a sensitivity of 95% and a specificity of 83%. Individual parameters representing the efficiency of ET opening during swallowing showed moderately accurate assignments of ears to their respective groups. Three factors captured approximately 98% of the variance among parameters: the first had negative loadings of the ETF structural parameters; the second had positive loadings of the muscle-assisted ET opening parameters; and the third had negative loadings of the muscle-assisted ET opening parameters and positive loadings of the structural parameters. These results show that ETF tests can correctly assign individual ears to physician-diagnosed ETD with high sensitivity and specificity and that ETF test parameters can be grouped into structural-functional categories.
Gillen, K L; Hughes, K T
1991-01-01
The complex regulation of flagellin gene expression in Salmonella typhimurium was characterized in vivo by using lac transcriptional fusions to the two flagellin structural genes (fliC [H1] and fljB [H2]). Phase variation was measured as the rate of switching of flagellin gene expression. Switching frequencies varied from 1/500 per cell per generation to 1/10,000 per cell per generation depending on the particular insertion and the direction of switching. There is a 4- to 20-fold bias in favor of switching from the fljB(On) to the fljB(Off) orientation. Random Tn10dTc insertions were isolated which failed to express flagellin. While most of these insertions mapped to loci known to be required for flagellin expression, several new loci were identified. The presence of functional copies of all of the genes responsible for complete flagellar assembly, except the hook-associated proteins (flgK, flgL, and fliD gene products), were required for expression of the fliC or fljB flagellin genes. Two novel loci involved in negative regulation of fliC and fljB in fla mutant backgrounds were identified. One of these loci, designated the flgR locus, mapped to the flg operon at 23 min on the Salmonella linkage map. An flgR insertion mutation resulted in relief of repression of the fliC and fljB genes in all fla mutant backgrounds except for mutants in the positive regulatory loci (flhC, flhD, and fliA genes). PMID:1848842
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nozaki, T., E-mail: nozaki@ecei.tohoku.ac.jp; Oida, M.; Ashida, T.
We investigated the effect of Pt insertion on a Cr{sub 2}O{sub 3}/Co exchange coupling system. The perpendicular exchange bias μ{sub 0}H{sub ex} decreased with increasing Pt insertion layer thickness, and we observed positive μ{sub 0}H{sub ex} for samples with relatively thick Pt insertion layers. We also examined the cooling field μ{sub 0}H{sub fc} dependence of μ{sub 0}H{sub ex} for the samples. At small μ{sub 0}H{sub fc}, all samples exhibited negative μ{sub 0}H{sub ex}. With increasing μ{sub 0}H{sub fc}, a shift of μ{sub 0}H{sub ex} from negative to positive was observed. In the past, similar behaviors were observed for FeF{sub 2}/Femore » systems exhibiting positive μ{sub 0}H{sub ex}. In addition, the μ{sub 0}H{sub fc} dependence of μ{sub 0}H{sub ex} was well fitted by an equation taking into account the Zeeman energy at the surface of an antiferromagnet as well as an antiferromagnetic exchange coupling. The results strongly suggest that (1) Cr{sub 2}O{sub 3} surface spin is affected by the external magnetic field and (2) the coupling at the Cr{sub 2}O{sub 3}/Pt/Co interface is antiferromagnetic.« less
Tsai, Dah-Shyang; Chang, Chuan-hua; Chiang, Wei-Wen; Lee, Kuei-Yi; Huang, Ying-Sheng
2014-10-24
Capacity degradation and ion insertion of a miniaturized electrochemical capacitor are studied using ionic liquid [EMI] [TFSI] as the electrolyte. This capacitor is featured with two comb-like electrodes of vertical carbon nanotubes, ∼70 μm in height and 20 μm in interelectrode gap. We quantify the levels of ion insertion damage with Raman spectroscopy after the electrode experiences 120 consecutive voltammetric cycles to various potential limits. Distinct structural damage emerges due to [EMI] when the negative potential reaches -1.7 V, and those due to [TFSI] arise when the positive potential reaches 1.7 V vs. RHE. Judging from the peak broadenings, [EMI] is more detrimental than [TFSI]. When the voltage window ΔU is set as less than or equal to 2.8 V, both electrode potentials are within the two intercalation limits, little or no decay is observed in 10(4) charge/discharge cycles. When ΔU is 3.4 V, the positive potential exceeds the upper limit, but the negative potential stays within the lower limit, the cell capacitance decreases moderately. When ΔU increases to 3.8 V, both electrodes suffer from damages because of exceeding the intercalation limits. And the cell capacitance decreases substantially, even leading to a premature failure.
NASA Astrophysics Data System (ADS)
Ui, Koichi; Yamamoto, Keigo; Ishikawa, Kohei; Minami, Takuto; Takeuchi, Ken; Itagaki, Masayuki; Watanabe, Kunihiro; Koura, Nobuyuki
The negative electrode performance of the electroplated Al film electrode in the LiCl saturated AlCl 3-1-ethyl-3-methylimizadolium chloride (EMIC) + SOCl 2 melt as the electrolyte for use in non-flammable lithium secondary batteries was evaluated. In the cyclic voltammogram of the electroplated Al film electrode in the melt, the oxidation and reduction waves corresponding to the electrochemical insertion/extraction reactions of the Li + ion were observed at 0-0.80 V vs. Li +/Li, which suggested that the electroplated Al film electrode operated well in the electrolyte. The almost flat potential profiles at about 0.40 V vs. Li +/Li on discharging were shown. The discharge capacity and charge-discharge efficiency was 236 mAh g -1 and 79.2% for the 1st cycle and it maintained 232 mAh g -1 and 77.9% after the 10th cycle. In addition, the initial charge-discharge efficiencies of the electroplated Al film electrode were higher than that of carbon electrodes. The main cathodic polarization reaction was the insertion of Li + ions, and side reactions hardly occurred due to the decomposition reaction of the melt because the Li content corresponding to the electricity was almost totally inserted into the film after charging.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hester, Brett R.; dos Santos, António M.; Molaison, Jamie J.
Defect perovskites (He 2–x⟂ x)(CaZr)F 6 can be prepared by inserting helium into CaZrF 6 at high pressure. They can be recovered to ambient pressure at low temperature. There are no prior examples of perovskites with noble gases on the A-sites. The insertion of helium gas into CaZrF 6 both elastically stiffens the material and reduces the magnitude of its negative thermal expansion. It also suppresses the onset of structural disorder, which is seen on compression in other media. Measurements of the gas released on warming to room temperature and Rietveld analyses of neutron diffraction data at low temperature indicatemore » that exposure to helium gas at 500 MPa leads to a stoichiometry close to (He 1⟂ 1)(CaZr)F 6. Helium has a much higher solubility in CaZrF 6 than silica glass or crystobalite. An analogue with composition (H 2) 2(CaZr)F 6 would have a volumetric hydrogen storage capacity greater than current US DOE targets. We anticipate that other hybrid perovskites with small neutral molecules on the A-site can also be prepared and that they will display a rich structural chemistry.« less
H-mode achievement and edge features in RFX-mod tokamak operation
NASA Astrophysics Data System (ADS)
Spolaore, M.; Cavazzana, R.; Marrelli, L.; Carraro, L.; Franz, P.; Spagnolo, S.; Zaniol, B.; Zuin, M.; Cordaro, L.; Dal Bello, S.; De Masi, G.; Ferro, A.; Finotti, C.; Grando, L.; Grenfell, G.; Innocente, P.; Kudlacek, O.; Marchiori, G.; Martines, E.; Momo, B.; Paccagnella, R.; Piovesan, P.; Piron, C.; Puiatti, M. E.; Recchia, M.; Scarin, P.; Taliercio, C.; Vianello, N.; Zanotto, L.
2017-11-01
The RFX-mod experiment is a fusion device designed to operate as a reversed field pinch (RFP), with a major radius R = 2 m and a minor radius a = 0.459 m. Its high versatility recently allowed operating it also as an ohmic tokamak, allowing comparative studies between the two configurations in the same device. The device is equipped with a state of the art MHD mode feedback control system providing a magnetic boundary effective control, by applying resonant or non-resonant magnetic perturbations (MP), both in RFP and in tokamak configurations. In the fusion community the application of MPs is widely studied as a promising tool to limit the impact of plasma filaments and ELMs (edge localized modes) on plasma facing components. An important new research line is the exploitation of the RFX-mod active control system for ELM mitigation studies. As a first step in this direction, this paper presents the most recent achievements in term of RFX-mod tokamak explored scenarios, which allowed the first investigation of the ohmic and edge biasing induced H-mode. The production of D-shaped tokamak discharges and the design and deployment of an insertable polarized electrode were accomplished. Reproducible H-mode phases were obtained with insertable electrode negative biasing in single null discharges, representing an unexplored scenario with this technique. Important modifications of the edge plasma density and flow properties are observed. During the achieved H-mode ELM-like electromagnetic composite filamentary structures are observed. They are characterized by clear vorticity and parallel current density patterns.
Use of LEU in the aqueous homogeneous medical isotope production reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ball, R.M.
1997-08-01
The Medical Isotope Production Reactor (MIPR) is an aqueous solution of uranyl nitrate in water, contained in an aluminum cylinder immersed in a large pool of water which can provide both shielding and a medium for heat exchange. The control rods are inserted at the top through re-entrant thimbles. Provision is made to remove radiolytic gases and recombine emitted hydrogen and oxygen. Small quantities of the solution can be continuously extracted and replaced after passing through selective ion exchange columns, which are used to extract the desired products (fission products), e.g. molybdenum-99. This reactor type is known for its largemore » negative temperature coefficient, the small amount of fuel required for criticality, and the ease of control. Calculation using TWODANT show that a 20% U-235 enriched system, water reflected can be critical with 73 liters of solution.« less
Lim, Geraldine S; Zidar, Jernej; Cheong, Daniel W; Jaenicke, Stephan; Klähn, Marco
2014-09-04
The impact of five different imidazolium-based ionic liquids (ILs) diluted in water on the properties of a bacterial plasma membrane is investigated using molecular dynamics (MD) simulations. Cations considered are 1-octyl-3-methylimidazolium (OMIM), 1-octyloxymethyl-3-methylimidazolium (OXMIM), and 1-tetradecyl-3-methylimidazolium (TDMIM), as well as the anions chloride and lactate. The atomistic model of the membrane bilayer is designed to reproduce the lipid composition of the plasma membrane of Gram-negative Escherichia coli. Spontaneous insertion of cations into the membrane is observed in all ILs. Substantially more insertions of OMIM than of OXMIM occur and the presence of chloride reduces cation insertions compared to lactate. In contrast, anions do not adsorb onto the membrane surface nor diffuse into the bilayer. Once inserted, cations are oriented in parallel to membrane lipids with cation alkyl tails embedded into the hydrophobic membrane core, while the imidazolium-ring remains mostly exposed to the solvent. Such inserted cations are strongly associated with one to two phospholipids in the membrane. The overall order of lipids decreased after OMIM and OXMIM insertions, while on the contrary the order of lipids in the vicinity of TDMIM increased. The short alkyl tails of OMIM and OXMIM generate voids in the bilayer that are filled by curling lipids. This cation induced lipid disorder also reduces the average membrane thickness. This effect is not observed after TDMIM insertions due to the similar length of cation alkyl chain and the fatty acids of the lipids. This lipid-mimicking behavior of inserted TDMIM indicates a high membrane affinity of this cation that could lead to an enhanced accumulation of cations in the membrane over time. Overall, the simulations reveal how cations are inserted into the bacterial membrane and how such insertions change its properties. Moreover, the different roles of cations and anions are highlighted and the fundamental importance of cation alkyl chain length and its functionalization is demonstrated.
Does insertion of intramuscular electromyographic electrodes alter motor behavior during locomotion?
Armour Smith, Jo; Kulig, Kornelia
2015-06-01
Intramuscular electromyography (EMG) is commonly used to quantify activity in the trunk musculature. However, it is unclear if the discomfort or fear of pain associated with insertion of intramuscular EMG electrodes results in altered motor behavior. This study examined whether intramuscular EMG affects locomotor speed and trunk motion, and examined the anticipated and actual pain associated with electrode insertion in healthy individuals and individuals with a history of low back pain (LBP). Before and after insertion of intramuscular electrodes into the lumbar and thoracic paraspinals, participants performed multiple repetitions of a walking turn at self-selected and controlled average speed. Low levels of anticipated and actual pain were reported in both groups. Self-selected locomotor speed was significantly increased following insertion of the electrodes. At the controlled speed, the amplitude of sagittal plane lumbo-pelvic motion decreased significantly post-insertion, but the extent of this change was the same in both groups. Lumbo-pelvic motion in the frontal and axial planes and thoraco-lumbar motion in all planes were not affected by the insertions. This study demonstrates that intramuscular EMG is an appropriate methodology to selectively quantify the activation patterns of the individual muscles in the paraspinal group, both in healthy individuals and individuals with a history of LBP. Copyright © 2015 Elsevier Ltd. All rights reserved.
Periplasmic quality control in biogenesis of outer membrane proteins.
Lyu, Zhi Xin; Zhao, Xin Sheng
2015-04-01
The β-barrel outer membrane proteins (OMPs) are integral membrane proteins that reside in the outer membrane of Gram-negative bacteria and perform a diverse range of biological functions. Synthesized in the cytoplasm, OMPs must be transported across the inner membrane and through the periplasmic space before they are assembled in the outer membrane. In Escherichia coli, Skp, SurA and DegP are the most prominent factors identified to guide OMPs across the periplasm and to play the role of quality control. Although extensive genetic and biochemical analyses have revealed many basic functions of these periplasmic proteins, the mechanism of their collaboration in assisting the folding and insertion of OMPs is much less understood. Recently, biophysical approaches have shed light on the identification of the intricate network. In the present review, we summarize recent advances in the characterization of these key factors, with a special emphasis on the multifunctional protein DegP. In addition, we present our proposed model on the periplasmic quality control in biogenesis of OMPs.
Dall'Olio, Stefania; Scotti, Emilio; Fontanesi, Luca; Tassinari, Marco
2014-01-01
The myostatin (MSTN) gene encodes a protein known to be a negative regulator of muscle mass in mammalian species. Different polymorphisms of the horse (Equus caballus) MSTN gene have been identified, including single nucleotide polymorphisms and a short interspersed nuclear element (SINE) insertion of 227 bp within the promoter of the gene. The SINE insertion has been associated with performance traits in Thoroughbred racehorses and it was proposed as a predictor of optimum racing distance. The aims of this study were to perform in silico analysis to identify putative gains or abrogation of transcription-factor binding sites (TFBSs) generated by the SINE allele of the promoter and to analyse the frequency of the SINE insertion in horses used for racing (gallop and trot) and other purposes. The SINE insertion was genotyped in 227 horses from 10 breeds belonging to different morphological types (brachimorphic, mesomorphic, meso-dolichomorphic and dolichomorphic). The presence of the insertion was confirmed in the Quarter Horse (SINE allele frequency of 0.81) and in the Thoroughbred (0.51), whereas the SINE allele did not segregate in any of the other analysed breeds. As the SINE MSTN gene polymorphism may be population or breed specific, it is not a useful marker for association studies in all breeds.
Mass-flow-rate-controlled fluid flow in nanochannels by particle insertion and deletion.
Barclay, Paul L; Lukes, Jennifer R
2016-12-01
A nonequilibrium molecular dynamics method to induce fluid flow in nanochannels, the insertion-deletion method (IDM), is introduced. IDM inserts and deletes particles within distinct regions in the domain, creating locally high and low pressures. The benefits of IDM are that it directly controls a physically meaningful quantity, the mass flow rate, allows for pressure and density gradients to develop in the direction of flow, and permits treatment of complex aperiodic geometries. Validation of IDM is performed, yielding good agreement with the analytical solution of Poiseuille flow in a planar channel. Comparison of IDM to existing methods indicates that it is best suited for gases, both because it intrinsically accounts for compressibility effects on the flow and because the computational cost of particle insertion is lowest for low-density fluids.
Munteanu, Shannon E; Landorf, Karl B; McClelland, Jodie A; Roddy, Edward; Cicuttini, Flavia M; Shiell, Alan; Auhl, Maria; Allan, Jamie J; Buldt, Andrew K; Menz, Hylton B
2017-04-27
This article describes the design of a parallel-group, participant- and assessor-blinded randomised controlled trial comparing the effectiveness of shoe-stiffening inserts versus sham shoe insert(s) for reducing pain associated with first metatarsophalangeal joint (MTPJ) osteoarthritis (OA). Ninety participants with first MTPJ OA will be randomised to receive full-length shoe-stiffening insert(s) (Carbon Fibre Spring Plate, Paris Orthotics, Vancouver, BC, Canada) plus rehabilitation therapy or sham shoe insert(s) plus rehabilitation therapy. Outcome measures will be obtained at baseline, 4, 12, 24 and 52 weeks; the primary endpoint for assessing effectiveness being 12 weeks. The primary outcome measure will be the foot pain domain of the Foot Health Status Questionnaire (FHSQ). Secondary outcome measures will include the function domain of the FHSQ, severity of first MTPJ pain (using a 100-mm Visual Analogue Scale), global change in symptoms (using a 15-point Likert scale), health status (using the Short-Form-12® Version 2.0 and EuroQol (EQ-5D-5L™) questionnaires), use of rescue medication and co-interventions, self-reported adverse events and physical activity levels (using the Incidental and Planned Activity Questionnaire). Data will be analysed using the intention-to-treat principle. Economic analysis (cost-effectiveness and cost-utility) will also be performed. In addition, the kinematic effects of the interventions will be examined at 1 week using a three-dimensional motion analysis system and multisegment foot model. This study will determine whether shoe-stiffening inserts are a cost-effective intervention for relieving pain associated with first MTPJ OA. The biomechanical analysis will provide useful insights into the mechanism of action of the shoe-stiffening inserts. Australian New Zealand Clinical Trials Registry, identifier: ACTRN12616000552482 . Registered on 28 April 2016.
Modeling and Control of Needles with Torsional Friction
Reed, Kyle B.; Okamura, Allison M.; Cowan, Noah J.
2010-01-01
A flexible needle can be accurately steered by robotically controlling the bevel tip orientation as the needle is inserted into tissue. Friction between the long, flexible needle shaft and the tissue can cause a significant discrepancy between the orientation of the needle tip and the orientation of the base where the needle angle is controlled. Our experiments show that several common phantom tissues used in needle steering experiments impart substantial friction forces to the needle shaft, resulting in a lag of over 45° for a 10 cm insertion depth in some phantoms; clinical studies report torques large enough to cause similar errors during needle insertions. Such angle discrepancies will result in poor performance or failure of path planners and image-guided controllers, since the needles used in percutaneous procedures are too small for state-of-the-art imaging to accurately measure the tip angle. To compensate for the angle discrepancy, we develop an estimator using a mechanics-based model of the rotational dynamics of a needle being inserted into tissue. Compared to controllers that assume a rigid needle in a frictionless environment, our estimator-based controller improves the tip angle convergence time by nearly 50% and reduces the path deviation of the needle by 70%. PMID:19695979
Keohane, John; Moore, Michael; O'Mahony, Seamus; Crosbie, Orla
2008-02-01
Biliary stent occlusion is a major complication of endoscopic stent insertion and results in repeat procedures. Various theories as to the etiology have been proposed, the most frequently studied is the attachment of gram negative bacteria within the stent. Several studies have shown prolongation of stent patency with antibiotic prophylaxis. We report the case of stent occlusion from a cast of a previously inserted straight biliary stent; a "stent cast" in an 86-year-old woman with obstructive jaundice. This was retrieved with the lithotrypter and she made an uneventful recovery. This is the first reported case of a biliary stent cast.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Hai-Feng, E-mail: hanlor@163.com, E-mail: lsb@nuaa.edu.cn; Nanjing Artillery Academy, Nanjing 211132; Liu, Shao-Bin, E-mail: hanlor@163.com, E-mail: lsb@nuaa.edu.cn
In this paper, the tunable all-angle negative refraction and photonic band gaps (PBGs) in two types of two-dimensional (2D) plasma photonic crystals (PPCs) composed of homogeneous plasma and dielectric (GaAs) with square-like Archimedean lattices (ladybug and bathroom lattices) for TM wave are theoretically investigated based on a modified plane wave expansion method. The type-1 structure is dielectric rods immersed in the plasma background, and the complementary structure is named as type-2 PPCs. Theoretical simulations demonstrate that the both types of PPCs with square-like Archimedean lattices have some advantages in obtaining the higher cut-off frequency, the larger PBGs, more number ofmore » PBGs, and the relative bandwidths compared to the conventional square lattices as the filling factor or radius of inserted rods is same. The influences of plasma frequency and radius of inserted rod on the properties of PBGs for both types of PPCs also are discussed in detail. The calculated results show that PBGs can be manipulated by the parameters as mentioned above. The possibilities of all-angle negative refraction in such two types of PPCs at low bands also are discussed. Our calculations reveal that the all-angle negative phenomena can be observed in the first two TM bands, and the frequency range of all-angle negative refraction can be tuned by changing plasma frequency. Those properties can be used to design the optical switching and sensor.« less
Nozzle insert for mixed mode fuel injector
Lawrence, Keith E [Peoria, IL
2006-11-21
A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set controlled respectively, by first and second needle valve members. The homogeneous charged nozzle outlet set is defined by a nozzle insert that is attached to an injector body, which defines the conventional nozzle outlet set. The nozzle insert is a one piece metallic component with a large diameter segment separated from a small diameter segment by an annular engagement surface. One of the needle valve members is guided on an outer surface of the nozzle insert, and the nozzle insert has an interference fit attachment to the injector body.
Behavioral analyses of killifish exposed to weightlessness in the Apollo-Soyuz test project
NASA Technical Reports Server (NTRS)
Hoffman, R. B.; Salinas, G. A.; Baky, A. A.
1977-01-01
Two groups of killifish, Fundulus heteroclitus, which were flown aboard Apollo-Soyuz, were subjected to postflight behavioral testing. The first group examined consisted of a graded series of embryos representing key developmental stages at orbital insertion (32-h, 66-h, and 128-h stages; pre-liftoff fertilization times). The tests revealed that the young adults from the flight 32-h stage had a significantly decreased positive geotaxis and increased negative phototaxis when compared with ground controls. These findings suggested a greater sensitization of the least-developed flight stage to post-hatching environmental influences. The second group consisted of 21-d old juveniles which were subjected to light orientation tests soon after recovery. No significant differences were detected.
Thrust Vector Control of an Overexpanded Supersonic Nozzle Using Pin Insertion and Rotating Airfoils
1991-12-01
12 THRUST VECTOR CONTROL OP AN OVEREXPANDED 3UPfRSONIC NOZZLE USING PIN INSERTION AND ROTATINO AIRFOILS THESIS Presented to the Faculty of the School...gather data that would aid in the evaluation of thrust vector control mechanisms for nozzle applications. I would like to thank my thesis advisor, Dr... Control Nozzle. MS Thesis . Air Force Institute of Technology (AU), Wright- Patterson AFB OH, December 1988. 4. Herup, Eric J. Confined Jet Thrust Vector
Effects of P Element Insertions on Quantitative Traits in Drosophila Melanogaster
Mackay, TFC.; Lyman, R. F.; Jackson, M. S.
1992-01-01
P element mutagenesis was used to construct 94 third chromosome lines of Drosophila melanogaster which contained on average 3.1 stable P element inserts, in an inbred host strain background previously free of P elements. The homozygous and heterozygous effects of the inserts on viability and abdominal and sternopleural bristle number were ascertained by comparing the chromosome lines with inserts to insert-free control lines of the inbred host strain. P elements reduced average homozygous viability by 12.2% per insert and average heterozygous viability by 5.5% per insert, and induced recessive lethal mutations at a rate of 3.8% per insert. Mutational variation for the bristle traits averaged over both sexes was 0.03V(e) per homozygous P insert and 0.003V(e) per heterozygous P insert, where V(e) is the environmental variance. Mutational variation was greater for the sexes considered separately because inserts had large pleiotropic effects on sex dimorphism of bristle characters. The distributions of homozygous effects of inserts on the bristle traits were asymmetrical, with the largest effects in the direction of reducing bristle number; and highly leptokurtic, with most of the increase in variance contributed by a few lines with large effects. The inserts had partially recessive effects on the bristle traits. Insert lines with extreme bristle effects had on average greatly reduced viability. PMID:1311697
Ochiai, Hiroshi; Sakamoto, Naoaki; Fujita, Kazumasa; Nishikawa, Masatoshi; Suzuki, Ken-ichi; Matsuura, Shinya; Miyamoto, Tatsuo; Sakuma, Tetsushi; Shibata, Tatsuo; Yamamoto, Takashi
2012-01-01
To understand complex biological systems, such as the development of multicellular organisms, it is important to characterize the gene expression dynamics. However, there is currently no universal technique for targeted insertion of reporter genes and quantitative imaging in multicellular model systems. Recently, genome editing using zinc-finger nucleases (ZFNs) has been reported in several models. ZFNs consist of a zinc-finger DNA-binding array with the nuclease domain of the restriction enzyme FokI and facilitate targeted transgene insertion. In this study, we successfully inserted a GFP reporter cassette into the HpEts1 gene locus of the sea urchin, Hemicentrotus pulcherrimus. We achieved this insertion by injecting eggs with a pair of ZFNs for HpEts1 with a targeting donor construct that contained ∼1-kb homology arms and a 2A-histone H2B–GFP cassette. We increased the efficiency of the ZFN-mediated targeted transgene insertion by in situ linearization of the targeting donor construct and cointroduction of an mRNA for a dominant-negative form of HpLig4, which encodes the H. pulcherrimus homolog of DNA ligase IV required for error-prone nonhomologous end joining. We measured the fluorescence intensity of GFP at the single-cell level in living embryos during development and found that there was variation in HpEts1 expression among the primary mesenchyme cells. These findings demonstrate the feasibility of ZFN-mediated targeted transgene insertion to enable quantification of the expression levels of endogenous genes during development in living sea urchin embryos. PMID:22711830
Effects of porous insert on flame dynamics in a lean premixed swirl-stabilized combustor
NASA Astrophysics Data System (ADS)
Brown, Marcus; Agrawal, Ajay; Allen, James; Kornegay, John
2016-11-01
In this study, we investigated different methods of determining the effect a porous insert has on flame dynamics during lean premixed combustion. A metallic porous insert is used to mitigate instabilities in a swirl-stabilized combustor. Thermoacoustic instabilities are seen as negative consequences of lean premixed combustion and eliminating them is the motivation for our research. Three different diagnostics techniques with high-speed Photron SA5 cameras were used to monitor flame characteristics. Particle image velocimetry (PIV) was used to observe vortical structures and recirculation zones within the combustor. Using planar laser induced fluorescence (PLIF), we were able to observe changes in the reaction zones during instabilities. Finally, utilizing a color high-speed camera, visual images depicting a flame's oscillations during the instability were captured. Using these monitoring techniques, we are able to support the claims made in previous studies stating that the porous insert in the combustor significantly reduces the thermoacoustic instability. Funding for this research was provided by the NSF REU site Grant EEC 1358991 and NASA Grant NNX13AN14A.
Goudarz Mehdikhani, Kaveh; Morales Moreno, Beatriz; Reid, Jeremy J; de Paz Nieves, Ana; Lee, Yuo-Yu; González Della Valle, Alejandro
2016-07-01
We studied the need to use a constrained insert for residual intraoperative instability and the 1-year result of patients undergoing total knee arthroplasty (TKA) for a varus deformity. In a control group, a "classic" subperiosteal release of the medial soft tissue sleeve was performed as popularized by pioneers of TKA. In the study group, an algorithmic approach that selectively releases and pie-crusts posteromedial structures in extension and anteromedial structures in flexion was used. All surgeries were performed by a single surgeon using measured resection technique, and posterior-stabilized, cemented implants. There were 228 TKAs in the control group and 188 in the study group. Outcome variables included the use of a constrained insert, and the Knee Society Score at 6 weeks, 4 months, and 1 year postoperatively. The effect of the release technique on use of constrained inserts and clinical outcomes were analyzed in a multivariate model controlling for age, sex, body mass index, and severity of deformity. The use of constrained inserts was significantly lower in study than in control patients (8% vs 18%; P = .002). There was no difference in the Knee Society Score and range of motion between the groups at last follow-up. No patient developed postoperative medial instability. This algorithmic, pie-crusting release technique resulted in a significant reduction in the use of constrained inserts with no detrimental effects in clinical results, joint function, and stability. As constrained TKA implants are more costly than nonconstrained ones, if the adopted technique proves to be safe in the long term, it may cause a positive shift in value for hospitals and cost savings in the health care system. Copyright © 2016 Elsevier Inc. All rights reserved.
Stirrup, Oliver T; Dunn, David T; Tostevin, Anna; Sabin, Caroline A; Pozniak, Anton; Asboe, David; Cox, Alison; Orkin, Chloe; Martin, Fabiola; Cane, Patricia
2018-04-16
The prevalence of HIV-1 resistance to antiretroviral therapies (ART) has declined in high-income countries over recent years, but drug resistance remains a substantial concern in many low and middle-income countries. The Q151M and T69 insertion (T69i) resistance mutations in the viral reverse transcriptase gene can reduce susceptibility to all nucleoside/tide analogue reverse transcriptase inhibitors, motivating the present study to investigate the risk factors and outcomes associated with these mutations. We considered all data in the UK HIV Drug Resistance Database for blood samples obtained in the period 1997-2014. Where available, treatment history and patient outcomes were obtained through linkage to the UK Collaborative HIV Cohort study. A matched case-control approach was used to assess risk factors associated with the appearance of each of the mutations in ART-experienced patients, and survival analysis was used to investigate factors associated with viral suppression. A further analysis using matched controls was performed to investigate the impact of each mutation on survival. A total of 180 patients with Q151M mutation and 85 with T69i mutation were identified, almost entirely from before 2006. Occurrence of both the Q151M and T69i mutations was strongly associated with cumulative period of virological failure while on ART, and for Q151M there was a particular positive association with use of stavudine and negative association with use of boosted-protease inhibitors. Subsequent viral suppression was negatively associated with viral load at sequencing for both mutations, and for Q151M we found a negative association with didanosine use but a positive association with boosted-protease inhibitor use. The results obtained in these analyses were also consistent with potentially large associations with other drugs. Analyses were inconclusive regarding associations between the mutations and mortality, but mortality was high for patients with low CD4 at detection. The Q151M and T69i resistance mutations are now very rare in the UK. Our results suggest that good outcomes are possible for people with these mutations. However, in this historic sample, viral load and CD4 at detection were important factors in determining prognosis.
Forgie, Marie M; Greer, Danielle M; Kram, Jessica J F; Vander Wyst, Kiley B; Salvo, Nicole P; Siddiqui, Danish S
2016-03-01
Foley catheters are used for cervical ripening during induction of labor. Previous studies suggest that use of a stylette (a thin, rigid wire) to guide catheter insertion decreases insertion failure. However, stylette effects on insertion outcomes have been sparsely studied. The purpose of this study was to compare catheter insertion times, patient-assessed pain levels, and insertion failure rates between women who received a digitally placed Foley catheter for cervical ripening with the aid of a stylette and women who received the catheter without a stylette. We conducted a randomized clinical trial of women aged ≥ 18 years who presented for induction of labor. Inclusion criteria were singletons with intact membranes and cephalic presentation. Women received a computer-generated random assignment of a Foley catheter insertion with a stylette (treatment group, n = 62) or without a stylette (control group, n = 61). For all women, a standard insertion technique protocol was used. Three primary outcomes were of interest, including the following: (1) insertion time (total minutes to successful catheter placement), (2) patient-assessed pain level (0-10), and (3) failure rate of the randomly assigned insertion method. Treatment control differences were first examined using the Pearson's test of independence and the Student t test. Per outcome, we also constructed 4 regression models, each including the random effect of physician and fixed effects of stylette use with patient nulliparity, a history of vaginal delivery, cervical dilation at presentation, or postgraduate year of the performing resident physician. Women who received the Foley catheter with the stylette vs without the stylette did not differ by age, race/ethnicity, body mass index, or any of several other characteristics. Regression models revealed that insertion time, patient pain, and insertion failure were unrelated to stylette use, nulliparity, and history of vaginal delivery. However, overall insertion time and failure were significantly influenced by cervical dilation, with insertion time decreasing by 21% (95% confidence interval [CI], 5-34%) and odds of failure decreasing by 71% (odds ratio, 0.29; 95% CI, 0.10-0.86) per 1 cm dilation. Resident postgraduate year also significantly influenced insertion time, with greater time required of physicians with less experience. Mean insertion time was 51% (95% CI, 23-69%) shorter for fourth-year than second-year residents. Statistically nonsignificant but prominent patterns in outcomes were also observed, suggesting stylette use may lengthen the overall insertion procedure but minimize variability in pain levels and decrease insertion failure. The randomized trial suggests that, even after accounting for nulliparity, history of vaginal delivery, cervical dilation, and physician experience, Foley catheter insertions with and without a stylette are equivalent in insertion times, patient pain levels, and failure of catheter placement. Copyright © 2016 Elsevier Inc. All rights reserved.
Dettenkofer, M; Wilson, C; Gratwohl, A; Schmoor, C; Bertz, H; Frei, R; Heim, D; Luft, D; Schulz, S; Widmer, A F
2010-06-01
To compare the efficacy of two commercially available, alcohol-based antiseptic solutions for preparation and care of central venous catheter (CVC) insertion sites, with and without octenidine dihydrochloride, a double-blind, randomized, controlled trial was undertaken in the haematology units and in one surgical unit of two university hospitals. Adult patients with a non-tunnelled CVC were randomly assigned to two different skin disinfection regimens at the insertion site: 0.1% octenidine with 30% 1-propanol and 45% 2-propanol, and as control 74% ethanol with 10% 2-propanol. Endpoints were (i) skin colonization at the insertion site; (ii) positive culture from the catheter tip (> or = 15 CFU); and (iii) occurrence of CVC-associated bloodstream infection (defined according to criteria set by the CDC). Four hundred patients with inserted CVC were enrolled from May 2002 through April 2005. Both groups were similar in respect of patient characteristics and co-morbidities. Skin colonization at the CVC insertion site during the first 10 days was significantly reduced by octenidine treatment (relative difference octenidine vs. control: 0.21; 95%CI: 0.11-0.39, p <0.0001). Positive culture of the catheter tip was significantly less frequent in the octenidine group (7.9%) than in the control group (17.8%): OR = 0.39 (95%CI: 0.20-0.80, p 0.009). Patients treated with octenidine had a non-significant reduction in catheter-associated bloodstream infections (4.1% vs. 8.3%; OR = 0.44; 95%CI: 0.18-1.08, p 0.081). Side effects were similar in both groups. This randomized controlled trial supports the results of two observational studies demonstrating octenidine in alcoholic solution to be a better option than alcohol alone for the prevention of CVC-associated infections.
Shin, Sung Joon; Lee, Ji-Ho; Lee, Jae Hyup
2017-07-01
A prospective, within-patient, left-right comparative study. To evaluate the efficacy of hydroxyapatite (HA) stick augmentation method by comparing the insertional torque of the pedicle screw in osteoporotic and nonosteoporotic patients. Unsatisfactory clinical outcomes after spine surgery in osteoporotic patients are related to pedicle screw loosening or pull-outs. HA, as a bone graft extender, has a possibility to enhance the fixation strength at the bone-screw interface. From November 2009 to December 2010, among patients who required bilateral pedicle screw fixation for lumbar spine surgery, 22 patients were enrolled, who recieved unilateral HA stick augmentation and completed intraoperative insertional torque measurement of each pedicle screws. On the basis of preoperative evaluation of bone mineral density, patients with osteoporosis had 2 HA sticks inserted unilaterally, and 1 stick for patients without osteoporosis. Pedicle screw loosening and pull-outs were assessed using 12-month postoperative CT scans and follow-up radiographs. Clinical evaluation was done preoperatively and at 1 year postoperatively, based on Visual Analog Scale score, Oswestry Disability Index, and Short Form-36 Health Survey. Regardless of bone mineral density, the average torque value of all pedicle screws with HA stick insertion (HA stick inserted group) was significantly higher than that of all pedicle screws without HA insertion (control group) (P<0.0001). Same results were seen in the HA stick inserted subgroups and the control subgroups within both of the osteoporosis group (P=0.009) and the nonosteoporosis group (P=0.0004). There was no statistically significant difference of the rate of pedicle screw loosening in between the HA stick inserted group and the control group. Clinical evaluation also showed no statistically significant difference in between patients with loosening and those without. The enhancement of initial pedicle screw fixation strength in osteoporotic patients can be achieved by HA stick augmentation.
NASA Astrophysics Data System (ADS)
Takamatsu, Kuniyoshi; Nakagawa, Shigeaki; Takeda, Tetsuaki
Safety demonstration tests using the High Temperature Engineering Test Reactor (HTTR) are in progress to verify its inherent safety features and improve the safety technology and design methodology for High-temperature Gas-cooled Reactors (HTGRs). The reactivity insertion test is one of the safety demonstration tests for the HTTR. This test simulates the rapid increase in the reactor power by withdrawing the control rod without operating the reactor power control system. In addition, the loss of coolant flow tests has been conducted to simulate the rapid decrease in the reactor power by tripping one, two or all out of three gas circulators. The experimental results have revealed the inherent safety features of HTGRs, such as the negative reactivity feedback effect. The numerical analysis code, which was named-ACCORD-, was developed to analyze the reactor dynamics including the flow behavior in the HTTR core. We have modified this code to use a model with four parallel channels and twenty temperature coefficients. Furthermore, we added another analytical model of the core for calculating the heat conduction between the fuel channels and the core in the case of the loss of coolant flow tests. This paper describes the validation results for the newly developed code using the experimental results. Moreover, the effect of the model is formulated quantitatively with our proposed equation. Finally, the pre-analytical result of the loss of coolant flow test by tripping all gas circulators is also discussed.
Priming cases disturb visual search patterns in screening mammography
NASA Astrophysics Data System (ADS)
Lewis, Sarah J.; Reed, Warren M.; Tan, Alvin N. K.; Brennan, Patrick C.; Lee, Warwick; Mello-Thoms, Claudia
2015-03-01
Rationale and Objectives: To investigate the effect of inserting obvious cancers into a screening set of mammograms on the visual search of radiologists. Previous research presents conflicting evidence as to the impact of priming in scenarios where prevalence is naturally low, such as in screening mammography. Materials and Methods: An observer performance and eye position analysis study was performed. Four expert breast radiologists were asked to interpret two sets of 40 screening mammograms. The Control Set contained 36 normal and 4 malignant cases (located at case # 9, 14, 25 and 37). The Primed Set contained the same 34 normal and 4 malignant cases (in the same location) plus 2 "primer" malignant cases replacing 2 normal cases (located at positions #20 and 34). Primer cases were defined as lower difficulty cases containing salient malignant features inserted before cases of greater difficulty. Results: Wilcoxon Signed Rank Test indicated no significant differences in sensitivity or specificity between the two sets (P > 0.05). The fixation count in the malignant cases (#25, 37) in the Primed Set after viewing the primer cases (#20, 34) decreased significantly (Z = -2.330, P = 0.020). False-Negatives errors were mostly due to sampling in the Primed Set (75%) in contrast to in the Control Set (25%). Conclusion: The overall performance of radiologists is not affected by the inclusion of obvious cancer cases. However, changes in visual search behavior, as measured by eye-position recording, suggests visual disturbance by the inclusion of priming cases in screening mammography.
Bortolotto, Tissiana; Melian, Karla; Krejci, Ivo
2013-10-01
The present study attempted to find a simple direct adhesive restorative technique for the restoration of Class 2 cavities. A self-etch adhesive system with a dual-cured core buildup composite resin (paste 1 + paste 2) was evaluated in its ability to restore proximo-occlusal cavities with margins located on enamel and dentin. The groups were: A, cavity filling (cf) with paste 1 (light-curing component) by using a layering technique; B, cf by mixing both pastes, bulk insertion, and dual curing; and C, cf by mixing both pastes, bulk insertion, and chemical curing. Two control groups (D, negative, bulk; and E, positive, layering technique) were included by restoring cavities with a classic three-step etch-and-rinse adhesive and a universal restorative composite resin. SEM margin analysis was performed before and after thermomechanical loading in a chewing simulator. Percentages (mean ± SD) of "continuous margins" were improved by applying the material in bulk and letting it self cure (54 ± 6) or dual cure (59 ± 9), and no significant differences were observed between these two groups and the positive control (44 ± 19). The present study showed that the dual-cured composite resin tested has the potential to be used as bulk filling material for Class 2 restorations. When used as filling materials, dual-cure composite resins placed in bulk can provide marginal adaptation similar to light-cured composites applied with a complex stratification technique.
Müller, G; Zimmermann, R
1987-01-01
Honeybee prepromelittin is correctly processed and imported by dog pancreas microsomes. Insertion of prepromelittin into microsomal membranes, as assayed by signal sequence removal, does not depend on signal recognition particle (SRP) and docking protein. We addressed the question as to how prepromelittin bypasses the SRP/docking protein system. Hybrid proteins between prepromelittin, or carboxy-terminally truncated derivatives, and the cytoplasmic protein dihydrofolate reductase from mouse were constructed. These hybrid proteins were analysed for membrane insertion and sequestration into microsomes. The results suggest the following: (i) The signal sequence of prepromelittin is capable of interacting with the SRP/docking protein system, but this interaction is not mandatory for membrane insertion; this is related to the small size of prepromelittin. (ii) In prepromelittin a cluster of negatively charged amino acids must be balanced by a cluster of positively charged amino acids in order to allow membrane insertion. (iii) In general, a signal sequence can be sufficient to mediate membrane insertion independently of SRP and docking protein in the case of short precursor proteins; however, the presence and distribution of charged amino acids within the mature part of these precursors can play distinct roles. Images Fig. 3. Fig. 4. Fig. 5. Fig. 6. Fig. 7. Fig. 8. Fig. 9. PMID:2820722
Nano-oxide-layer insertion and specular effects in spin valves: Experiment and theory
NASA Astrophysics Data System (ADS)
Wang, L.; Qiu, J. J.; McMahon, W. J.; Li, K. B.; Wu, Y. H.
2004-06-01
We report a systematic study of NOL (nano-oxide-layer) insertion and specular effects on the giant magnetoresistance (GMR) of single, synthetic, and dual spin valves, using a semiclassical Boltzmann theory. It is confirmed that the GMR ratio is enhanced by NOL insertion inside the pinned layer or after the free layer. The enhancements are primarily due to the contribution of the majority carriers. The NOL insertions inside the inactive layers of spin valves such as the seed, under, and capping layers reduce the GMR ratio. Though introducing a NOL before or after the Cu spacer would, in principle, significantly suppress the GMR ratio due to the blocking effect or the average effect of different spin channels, large positive or negative (inverse) GMR is found by assuming spin-dependent NOL specular reflections. We have also demonstrated that specular reflection, even beyond a capping layer, may result in reduction of GMR. Upon appropriate NOL insertion, the amplitude of curve of GMR versus thickness of individual layer of spin valves may be generally enhanced, but the shape may change, depending on whether the distance of the NOL to the layer is small or large (distance effect). Finally, it is found that most results obtained for the single realistic spin valves are applicable to synthetic and dual spin valves.
Singh, Rameet H; Thaxton, Lauren; Carr, Shannon; Leeman, Lawrence; Schneider, Emily; Espey, Eve
2016-11-01
To evaluate the effectiveness of inhaled nitrous oxide for pain management among nulliparous women undergoing intrauterine device (IUD) insertion. A double-blind, randomized controlled trial was conducted among nulliparous women aged 13-45years who underwent IUD insertion at a US center between October 1, 2013, and August 31, 2014. Using a computer-generated randomization sequence, participants were randomly assigned to inhale either oxygen (O 2 ) or a mixture of 50% nitrous oxide and 50% oxygen (N 2 O/O 2 ) through a nasal mask for 2minutes before insertion. Only the person administering the inhalation agent was aware of group assignment. The primary outcome was maximum pain assessed 2minutes after insertion via a 100-mm visual analog scale. Analyses were by intention to treat. Forty women were assigned to each group. Mean maximum pain score at the time of insertion was 54.3±24.8mm for the N 2 O/O 2 group and 55.3±20.9mm for the O 2 group (P=0.86). Adverse effects were reported for 6 (15%) women in the N 2 O/O 2 group and 7 (18%) in the O 2 group (P=0.32). N 2 O/O 2 did not reduce the pain of IUD insertion among nulliparous women. ClinicalTrials.gov: NCT02391714. Published by Elsevier Ireland Ltd.
WATER PUMP HOUSE, TRA619, AND TWO WATER STORAGE RESERVOIRS. INDUSTRIAL ...
WATER PUMP HOUSE, TRA-619, AND TWO WATER STORAGE RESERVOIRS. INDUSTRIAL WINDOWS AND COPING STRIPS AT TOP OF WALLS AND ENTRY VESTIBULE. BOLLARDS PROTECT UNDERGROUND FACILITIES. SWITCHYARD AT RIGHT EDGE OF VIEW. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION PRINTED ON ORIGINAL NEGATIVE. INL NEGATIVE NO. 3816. Unknown Photographer, 11/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Bhattarai, Sushila; Alany, Raid G; Bunt, Craig R; Abdelkader, Hamdy; Rathbone, Michael J
2015-01-01
This manuscript reports (for the first time) on antibiotic-free polymeric inserts for the prevention and/or treatment of bovine mastitis. Polyethylene oxide (PEO)-based inserts were prepared using different concentrations of various hydrophilic polymers and water-soluble and water-insoluble drug-release-modifying excipients. A simple and scalable melt-extrusion method was employed to prepare the inserts. The prepared inserts were characterised for their dimension, rheological and mechanical properties. The in vitro release of a model bacteriostatic drug (salicylic acid) from the prepared inserts was studied to demonstrate the effectiveness and reproducibility of the melt-extrusion manufacturing method. Further, the in vitro stability of the inserts was evaluated using gel permeation chromatography (GPC) to monitor any change in molecular weight under real-time and accelerated storage conditions. The investigated inserts were stable at accelerated storage conditions over a period of 6 months. PEO inserts have the potential to serve a dual purpose, act as a physical barrier against pathogens invading the teat canal of cows and possibly control the release of a drug.
Biochemical and genetic analyses of acetoin catabolism in Alcaligenes eutrophus.
Fründ, C; Priefert, H; Steinbüchel, A; Schlegel, H G
1989-01-01
In genetic studies on the catabolism of acetoin in Alcaligenes eutrophus, we used Tn5::mob-induced mutants which were impaired in the utilization of acetoin as the sole carbon source for growth. The transposon-harboring EcoRI restriction fragments from 17 acetoin-negative and slow-growing mutants (class 2a) and from six pleiotropic mutants of A. eutorphus, which were acetoin-negative and did not grow chemolithoautotrophically (class 2b), were cloned from pHC79 gene banks. The insertions of Tn5 were mapped on four different chromosomal EcoRI restriction fragments (A, C, D, and E) in class 2a mutants. The native DNA fragments were cloned from a lambda L47 or from a cosmid gene bank. Evidence is provided that fragments A (21 kilobase pairs [kb]) and C (7.7 kb) are closely linked in the genome; the insertions of Tn5 covered a region of approximately 5 kb. Physiological experiments revealed that this region encodes for acetoin:dichlorophenol-indophenol oxidoreductase, a fast-migrating protein, and probably for one additional protein that is as yet unknown. In mutants which were not completely impaired in growth on acetoin but which grew much slower and after a prolonged lag phase, fragments D (7.2 kb) and E (8.1 kb) were inactivated by insertion of Tn5::mob. No structural gene could be assigned to the D or E fragments. In class 2b mutants, insertions of Tn5 were mapped on fragment B (11.3 kb). This fragment complemented pleiotropic hno mutants in trans; these mutants were impaired in the formation of a rpoN-like protein. The expression of the gene cluster on fragments A and C seemed to be rpoN dependent. PMID:2556366
Hepatitis B Virus Core Gene Mutations Which Block Nucleocapsid Envelopment
Koschel, Matthias; Oed, Daniela; Gerelsaikhan, Tudevdagwa; Thomssen, Reiner; Bruss, Volker
2000-01-01
Recently we generated a panel of hepatitis B virus core gene mutants carrying single insertions or deletions which allowed efficient expression of the core protein in bacteria and self-assembly of capsids. Eleven of these mutations were introduced into a eukaryotic core gene expression vector and characterized by trans complementation of a core-negative HBV genome in cotransfected human hepatoma HuH7 cells. Surprisingly, four mutants (two insertions [EFGA downstream of A11 and LDTASALYR downstream of R39] and two deletions [Y38-R39-E40 and L42]) produced no detectable capsids. The other seven mutants supported capsid formation and pregenome packaging/viral minus- and plus-strand-DNA synthesis but to different levels. Four of these seven mutants (two insertions [GA downstream of A11 and EHCSP downstream of P50] and two deletions [S44 and A80]) allowed virion morphogenesis and secretion. The mutant carrying a deletion of A80 at the tip of the spike protruding from the capsid was hepatitis B virus core antigen negative but wild type with respect to virion formation, indicating that this site might not be crucial for capsid-surface protein interactions during morphogenesis. The other three nucleocapsid-forming mutants (one insertion [LS downstream of S141] and two deletions [T12 and P134]) were strongly blocked in virion formation. The corresponding sites are located in the part of the protein forming the body of the capsid and not in the spike. These mutations may alter sites on the particle which contact surface proteins during envelopment, or they may block the appearance of a signal for the transport or the maturation of the capsid which is linked to viral DNA synthesis and required for envelopment. PMID:10590084
Feedback Control for Functional Electrical Stimulation of Paralyzed Muscle.
1981-03-01
and pubic symphysis. Insertion - tibia and fascia of shank. Action - adducts the leg. 3. Iliopsoas - a triangular shaped muscle which is caudal to the...first caudal vertebrae. Insertion - fascia lata and greater throchanter of femur. Action - abducts thigh. 6. Caudofemoralis - band of muscle posterior...and extends shank. 7. Biceps femoris - very broad mscle posterior to the fascia lata. Origin - tiiherositv of ishium. Insertion - patella, tibia, and
2012-01-01
Introduction Catheter-related bloodstream infections (CRBSIs) associated with short-term central venous catheters (CVCs) in intensive care unit (ICU) patients are a major clinical problem. Bacterial colonization of the skin at the CVC insertion site is an important etiologic factor for CRBSI. The aim of this study was to assess the efficacy of medical-grade honey in reducing bacterial skin colonization at insertion sites. Methods A prospective, single-center, open-label randomized controlled trial was performed at the ICU of a university hospital in The Netherlands to assess the efficacy of medical-grade honey to reduce skin colonization of insertion sites. Medical-grade honey was applied in addition to standard CVC-site dressing and disinfection with 0.5% chlorhexidine in 70% alcohol. Skin colonization was assessed on a daily basis before CVC-site disinfection. The primary end point was colonization of insertion sites with >100 colony-forming units at the last sampling before removal of the CVC or transfer of the patient from the ICU. Secondary end points were quantitative levels of colonization of the insertion sites and colonization of insertion sites stratified for CVC location. Results Colonization of insertion sites was not affected by the use of medical-grade honey, as 44 (34%) of 129 and 36 (34%) of 106 patients in the honey and standard care groups, respectively, had a positive skin culture (P = 0.98). Median levels of skin colonization at the last sampling were 1 (0 to 2.84) and 1 (0 to 2.70) log colony-forming units (CFUs)/swab for the honey and control groups, respectively (P = 0.94). Gender, days of CVC placement, CVC location, and CVC type were predictive for a positive skin culture. Correction for these variables did not change the effect of honey on skin-culture positivity. Conclusions Medical-grade honey does not affect colonization of the skin at CVC insertion sites in ICU patients when applied in addition to standard disinfection with 0.5% chlorhexidine in 70% alcohol. Trial registration Netherlands Trial Registry, NTR1652. PMID:23111148
Kwakman, Paulus H; Müller, Marcella C; Binnekade, Jan M; van den Akker, Johannes P; de Borgie, Corianne A; Schultz, Marcus J; Zaat, Sebastian A
2012-10-30
Catheter-related bloodstream infections (CRBSIs) associated with short-term central venous catheters (CVCs) in intensive care unit (ICU) patients are a major clinical problem. Bacterial colonization of the skin at the CVC insertion site is an important etiologic factor for CRBSI. The aim of this study was to assess the efficacy of medical-grade honey in reducing bacterial skin colonization at insertion sites. A prospective, single-center, open-label randomized controlled trial was performed at the ICU of a university hospital in The Netherlands to assess the efficacy of medical-grade honey to reduce skin colonization of insertion sites. Medical-grade honey was applied in addition to standard CVC-site dressing and disinfection with 0.5% chlorhexidine in 70% alcohol. Skin colonization was assessed on a daily basis before CVC-site disinfection. The primary end point was colonization of insertion sites with >100 colony-forming units at the last sampling before removal of the CVC or transfer of the patient from the ICU. Secondary end points were quantitative levels of colonization of the insertion sites and colonization of insertion sites stratified for CVC location. Colonization of insertion sites was not affected by the use of medical-grade honey, as 44 (34%) of 129 and 36 (34%) of 106 patients in the honey and standard care groups, respectively, had a positive skin culture (P = 0.98). Median levels of skin colonization at the last sampling were 1 (0 to 2.84) and 1 (0 to 2.70) log colony-forming units (CFUs)/swab for the honey and control groups, respectively (P = 0.94). Gender, days of CVC placement, CVC location, and CVC type were predictive for a positive skin culture. Correction for these variables did not change the effect of honey on skin-culture positivity. Medical-grade honey does not affect colonization of the skin at CVC insertion sites in ICU patients when applied in addition to standard disinfection with 0.5% chlorhexidine in 70% alcohol. Netherlands Trial Registry, NTR1652.
Hayashi, J; Nishikawa, K; Hirano, R; Noguchi, T; Yoshimura, F
2000-01-01
Porphyromonas gingivalis, a periodontopathogen, is an oral anaerobic gram-negative bacterium with numerous fimbriae on the cell surface. Fimbriae have been considered to be an important virulence factor in this organism. We analyzed the genomic DNA of transposon-induced, fimbria-deficient mutants derived from ATCC 33277 and found that seven independent mutants had transposon insertions within the same restriction fragment. Cloning and sequencing of the disrupted region from one of the mutants revealed two adjacent open reading frames (ORFs) which seemed to encode a two-component signal transduction system. We also found that six of the mutants had insertions in a gene, fimS, a homologue of the genes encoding sensor kinase, and that the insertion in the remaining one disrupted the gene immediately downstream, fimR, a homologue of the response regulator genes in other bacteria. These findings suggest that this two-component regulatory system is involved in fimbriation of P. gingivalis.
Nilsson, Anders K; Andersson, Mats X
2017-01-01
A striking and unexpected biochemical phenotype was found in an insertion mutant line in the model plant Arabidopsis thaliana . One of two investigated insertion mutant lines in the gene encoding the phosphate transporter PHT4;1 demonstrated a prominent loss of trienoic fatty acids, whereas the other insertion line was indistinguishable from wild type in this aspect. We demonstrate that the loss of trienoic fatty acids was due to a remnant inactive negative selection marker gene in this particular transposon tagged line, pht4;1-3 . This constitutes a cautionary tale that warns of the importance to confirm the loss of this type of selection markers and the importance of verifying the relationship between a phenotype and genotype by more than one independent mutant line or alternatively genetic complementation.
Intrauterine device insertion in the postpartum period: a systematic review.
Sonalkar, Sarita; Kapp, Nathalie
2015-02-01
Given new research on postpartum placement of levonorgestrel and copper intrauterine devices (IUDs), our objective was to update a prior systematic review of the safety and expulsion rates of postpartum IUDs. We searched MEDLINE, CENTRAL, LILACS, POPLINE, Web of Science, and ClinicalTrials.gov databases for articles between the database inception until July 2013. We included studies that compared IUD insertion time intervals and routes during the postpartum period. We used standard abstract forms and the United States Preventive Services Task Force grading system to summarise and assess the quality of the evidence. We included 18 articles. New evidence suggests that a levonorgestrel releasing-intrauterine system (LNG-IUS) insertion within 48 hours of delivery is safe. Postplacental insertion and insertion between 10 minutes and 48 hours after delivery result in higher expulsion rates than insertion 4 to 6 weeks postpartum, or non-postpartum insertion. Insertion at the time of caesarean section is associated with lower expulsion rates than postplacental insertion at the time of vaginal delivery. This review supports the evidence that insertion of an intrauterine contraceptive within the first 48 hours of vaginal or caesarean delivery is safe. Expulsion rates should be further studied in larger randomised controlled trials.
Biological control of invasive plant species: a reassessment for the Anthropocene.
Seastedt, Timothy R
2015-01-01
The science of finding, testing and releasing herbivores and pathogens to control invasive plant species has achieved a level of maturity and success that argues for continued and expanded use of this program. The practice, however, remains unpopular with some conservationists, invasion biologists, and stakeholders. The ecological and economic benefits of controlling densities of problematic plant species using biological control agents can be quantified, but the risks and net benefits of biological control programs are often derived from social or cultural rather than scientific criteria. Management of invasive plants is a 'wicked problem', and local outcomes to wicked problems have both positive and negative consequences differentially affecting various groups of stakeholders. The program has inherent uncertainties; inserting species into communities that are experiencing directional or even transformational changes can produce multiple outcomes due to context-specific factors that are further confounded by environmental change drivers. Despite these uncertainties, biological control could play a larger role in mitigation and adaptation strategies used to maintain biological diversity as well as contribute to human well-being by protecting food and fiber resources. © 2014 The Author New Phytologist © 2014 New Phytologist Trust.
Hawke, Basil C.
1986-01-01
A control rod drive uses gravitational forces to insert one or more control rods upwardly into a reactor core from beneath the reactor core under emergency conditions. The preferred control rod drive includes a vertically movable weight and a mechanism operatively associating the weight with the control rod so that downward movement of the weight is translated into upward movement of the control rod. The preferred control rod drive further includes an electric motor for driving the control rods under normal conditions, an electrically actuated clutch which automatically disengages the motor during a power failure and a decelerator for bringing the control rod to a controlled stop when it is inserted under emergency conditions into a reactor core.
18. Photocopy, "Light house for ship shoals, details of the ...
18. Photocopy, "Light house for ship shoals, details of the apparatus for inserting the piles into the shoal, sheet no. 53", National Archives (8" x 10" print from 4" x 5" negative) - Ship Shoal Light Station, Gulf of Mexico, Theriot, Terrebonne Parish, LA
Barros, Marcos Alexandre; Cervone, Gabriel Lopes de Faria; Costa, André Luis Serigatti
2015-01-01
Objective To objectively and subjectively evaluate the functional result from before to after surgery among patients with a diagnosis of an isolated avulsion fracture of the posterior cruciate ligament who were treated surgically. Method Five patients were evaluated by means of reviewing the medical files, applying the Lysholm questionnaire, physical examination and radiological examination. For the statistical analysis, a significance level of 0.10 and 95% confidence interval were used. Results According to the Lysholm criteria, all the patients were classified as poor (<64 points) before the operation and evolved to a mean of 96 points six months after the operation. We observed that 100% of the posterior drawer cases became negative, taking values less than 5 mm to be negative. Conclusion Surgical methods with stable fixation for treating avulsion fractures at the tibial insertion of the posterior cruciate ligament produce acceptable functional results from the surgical and radiological points of view, with a significance level of 0.042. PMID:27218073
Su, Jie; Feng, Liping; Zeng, Wei; Liu, Zhengtang
2017-06-08
Metal/insertion-MoS 2 sandwich interfaces are designed to reduce the Schottky barriers at metal-MoS 2 interfaces. The effects of geometric and electronic structures of two-dimensional (2D) insertion materials on the contact properties of metal/insertion-MoS 2 interfaces are comparatively studied by first-principles calculations. Regardless of the geometric and electronic structures of 2D insertion materials, Fermi level pinning effects and charge scattering at the metal/insertion-MoS 2 interface are weakened due to weak interactions between the insertion and MoS 2 layers, no gap states and negligible structural deformations for MoS 2 layers. The Schottky barriers at metal/insertion-MoS 2 interfaces are induced by three interface dipoles and four potential steps that are determined by the charge transfers and structural deformations of 2D insertion materials. The lower the electron affinities of 2D insertion materials, the more are the electrons lost from the Sc surface, resulting in lower n-type Schottky barriers at Sc/insertion-MoS 2 interfaces. The larger the ionization potentials and the thinner the thicknesses of 2D insertion materials, the fewer are the electrons that accumulate at the Pt surface, leading to lower p-type Schottky barriers at Pt/insertion-MoS 2 interfaces. All Sc/insertion-MoS 2 interfaces exhibited ohmic characters. The Pt/BN-MoS 2 interface exhibits the lowest p-type Schottky barrier of 0.52 eV due to the largest ionization potential (∼6.88 eV) and the thinnest thickness (single atomic layer thickness) of BN. These results in this work are beneficial to understand and design high performance metal/insertion-MoS 2 interfaces through 2D insertion materials.
Wang, Zenglei; Wang, Yingna; Cabrera, Mynthia; Zhang, Yanmei; Gupta, Bhavna; Wu, Yanrui; Kemirembe, Karen; Hu, Yue; Liang, Xiaoying; Brashear, Awtum; Shrestha, Sony; Li, Xiaolian; Miao, Jun; Sun, Xiaodong; Yang, Zhaoqing; Cui, Liwang
2015-11-01
Artemisinin resistance in Plasmodium falciparum parasites in Southeast Asia is a major concern for malaria control. Its emergence at the China-Myanmar border, where there have been more than 3 decades of artemisinin use, has yet to be investigated. Here, we comprehensively evaluated the potential emergence of artemisinin resistance and antimalarial drug resistance status in P. falciparum using data and parasites from three previous efficacy studies in this region. These efficacy studies of dihydroartemisinin-piperaquine combination and artesunate monotherapy of uncomplicated falciparum malaria in 248 P. falciparum patients showed an overall 28-day adequate clinical and parasitological response of >95% and day 3 parasite-positive rates of 6.3 to 23.1%. Comparison of the 57 K13 sequences (24 and 33 from day 3 parasite-positive and -negative cases, respectively) identified nine point mutations in 38 (66.7%) samples, of which F446I (49.1%) and an N-terminal NN insertion (86.0%) were predominant. K13 propeller mutations collectively, the F446I mutation alone, and the NN insertion all were significantly associated with day 3 parasite positivity. Increased ring-stage survival determined using the ring-stage survival assay (RSA) was highly associated with the K13 mutant genotype. Day 3 parasite-positive isolates had ∼10 times higher ring survival rates than day 3 parasite-negative isolates. Divergent K13 mutations suggested independent evolution of artemisinin resistance. Taken together, this study confirmed multidrug resistance and emergence of artemisinin resistance in P. falciparum at the China-Myanmar border. RSA and K13 mutations are useful phenotypic and molecular markers for monitoring artemisinin resistance. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
NASA Astrophysics Data System (ADS)
Mehta, Sohan S.; Ganta, Lakshmi K.; Chauhan, Vikrant; Wu, Yixu; Singh, Sunil; Ann, Chia; Subramany, Lokesh; Higgins, Craig; Erenturk, Burcin; Srivastava, Ravi; Singh, Paramjit; Koh, Hui Peng; Cho, David
2015-03-01
Immersion based 20nm technology node and below becoming very challenging to chip designers, process and integration due to multiple patterning to integrate one design layer . Negative tone development (NTD) processes have been well accepted by industry experts for enabling technologies 20 nm and below. 193i double patterning is the technology solution for pitch down to 80 nm. This imposes tight control in critical dimension(CD) variation in double patterning where design patterns are decomposed in two different masks such as in litho-etch-litho etch (LELE). CD bimodality has been widely studied in LELE double patterning. A portion of CD tolerance budget is significantly consumed by variations in CD in double patterning. The objective of this work is to study the process variation challenges and resolution in the Negative Tone Develop Process for 20 nm and Below Technology Node. This paper describes the effect of dose slope on CD variation in negative tone develop LELE process. This effect becomes even more challenging with standalone NTD developer process due to q-time driven CD variation. We studied impact of different stacks with combination of binary and attenuated phase shift mask and estimated dose slope contribution individually from stack and mask type. Mask 3D simulation was carried out to understand theoretical aspect. In order to meet the minimum insulator requirement for the worst case on wafer the overlay and critical dimension uniformity (CDU) budget margins have slimmed. Besides the litho process and tool control using enhanced metrology feedback, the variation control has other dependencies too. Color balancing between the two masks in LELE is helpful in countering effects such as iso-dense bias, and pattern shifting. Dummy insertion and the improved decomposition techniques [2] using multiple lower priority constraints can help to a great extent. Innovative color aware routing techniques [3] can also help with achieving more uniform density and color balanced layouts.
MPL mutation profile in JAK2 mutation-negative patients with myeloproliferative disorders.
Ma, Wanlong; Zhang, Xi; Wang, Xiuqiang; Zhang, Zhong; Yeh, Chen-Hsiung; Uyeji, Jennifer; Albitar, Maher
2011-03-01
Mutations in the thrombopoietin receptor gene (myeloproliferative leukemia, MPL) have been reported in patients with JAK2 V617F-negative chronic myeloproliferative disorders (MPDs). We evaluated the prevalence of MPL mutations relative to JAK2 mutations in patients with suspected MPDs. A total of 2790 patient samples submitted for JAK2 mutation analysis were tested using real-time polymerase chain reaction and bidirectional sequencing of plasma RNA. JAK2 V617F-negative samples were tested for JAK2 exons 12 to 14 mutations, and those with negative results were then tested for mutations in MPL exons 10 and 11. Of the 2790 patients, 529 (18.96%) had V617F, 12 (0.43%) had small insertions or deletions in exon 12, and 7 (0.25%) had other JAK2 mutations in exons 12 to 14. Of the 2242 JAK2 mutation-negative patients, 68 (3.03%) had MPL mutations. W515L was the predominant MPL mutation (n=46; 68%), and 10 (15%) patients had other W515 variants. The remaining MPL mutations (n=12, 17%) were detected at other locations in exons 10 and 11 and included 3 insertion/deletion mutations. The S505N mutation, associated with familial MPD, was detected in 3 patients. Overall, for every 100 V617F mutations in patients with suspected MPDs, there were 12.9 MPL mutations, 2.3 JAK2 exon 12 mutations, and 1.3 JAK2 exons 13 to 14 mutations. These findings suggest that MPL mutation screening should be performed before JAK2 exons 12 to 14 testing in JAK2 V617F-negative patients with suspected MPDs.
Friedrich, Mirco; Bergdolt, Christian; Haubruck, Patrick; Bruckner, Thomas; Kowalewski, Karl-Friedrich; Müller-Stich, Beat Peter; Tanner, Michael C; Nickel, Felix
2017-02-06
Chest tube insertion is a standard intervention for management of various injuries of the thorax. Quick and accurate execution facilitates efficient therapy without further complications. Here, we propose a new training concept comprised of e-learning elements as well as continuous rating using an objective structured assessment of technical skills (OSATS) tool. The study protocol is presented for a randomized trial to evaluate e-learning with app-based serious gaming for chest drain insertion. The proposed randomized trial will be carried out at the Department of Orthopedics and Traumatology at Heidelberg University in the context of regular curricular teaching for medical students (n = 90, 3rd to 6th year). The intervention group will use e-learning with the serious gaming app Touch Surgery (TM) for chest drain insertion, whereas the control group uses serious gaming for an unrelated procedure. Primary endpoint is operative performance of chest drain insertion in a porcine cadaveric model according to OSATS. The randomized trial will help determine the value of e-learning with the serious gaming app Touch Surgery (TM) for chest drain insertion by using the OSATS score. The study will improve surgical training for trauma situations. Trial Registration Number, DRKS00009994 . Registered on 27 May 2016.
Method of creating a controlled interior surface configuration of passages within a substrate
Dembowski, Peter V.; Schilke, Peter W.
1983-01-01
A method of creating a controlled interior surface configuration of passages within a substrate, particularly cooling passages of nozzles or buckets of a gas turbine, involves the hot isostatic pressing of a leachable passage insert whose surface carries the female image of the desired interior surface configuration inside the substrate followed by leaching of the insert from the substrate.
A. Dan Wilson; D.G. Lester
1996-01-01
Four trench insert materials, including water-permeable Typar® polyethylene spunbonded fabric, Biobarrier® or Typar® with trifluralin-impregnated nodules, and water-impermeable polyethylene Geomembrane liners of two thicknesses (20 and 30 mil) were tested for effectiveness in improving trenches as physical barriers to root transmission for control of oak wilt. Research...
Cornelisse, Vincent J; Walker, Sandra; Phillips, Tiffany; Hocking, Jane S; Bradshaw, Catriona S; Lewis, David A; Prestage, Garrett Paul; Grulich, Andrew E; Fairley, Christopher K; Chow, Eric P F
2018-01-22
Oropharyngeal gonorrhoea is common among men who have sex with men (MSM). We aimed to clarify which oral sex practices were independent risk factors for oropharyngeal gonorrhoea: tongue kissing, receptive oro-penile sex (fellatio) or insertive oro-anal sex (rimming), and whether daily use of mouthwash and recent antibiotic use was protective. In 2015, we conducted an age-matched case-control study of MSM who attended the Melbourne Sexual Health Centre. Cases had tested positive for oropharyngeal gonorrhoea by nucleic acid amplification testing, and controls had tested negative. Questionnaire items included tongue kissing, oral sex practices, condom use, recent antibiotic use, mouthwash use and alcohol consumption. We identified 177 cases, age matched to 354 controls. In univariable analyses, cases were 1.90 times (95% CI 1.13 to 3.20) more likely than controls to have had casual sexual partners (CSP) in the preceding 3 months, were 2.17 times (95% CI 1.31 to 3.59) more likely to have kissed CSP and were 2.04 times (95% CI 1.26 to 3.30) more likely to have had receptive oro-penile sex with CSP. Oropharyngeal gonorrhoea was not associated with insertive oro-anal sex or mouthwash use. The number of CSP for tongue kissing and receptive oral sex and total CSP were highly correlated, and in multivariable analysis neither kissing nor receptive oro-penile sex was significantly associated with having oropharyngeal gonorrhoea, after adjusting for total number of CSP. The finding that oropharyngeal gonorrhoea was associated with a higher number of sexual partners but not specific sexual practices highlights the need for further research in the area of gonorrhoea transmission to define the probability of transmission from specific sex acts. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Yin, Yu-Feng; Lin, Yen-Chen; Tsai, Tsung-Han; Shen, Yi-Chun; Huang, Jianjang
2013-01-15
In recent years, researchers have demonstrated negative refraction theoretically and experimentally by pumping optical power into photonic crystal (PhC) or waveguide structures. The concept of negative refraction can be used to create a perfect lens that focuses an object smaller than the wavelength. By inserting two-dimensional PhCs into the peripheral of a semiconductor light emitting structure, this study presents an electroluminescent device with negative refraction in the visible wavelength range. This approach produces polarization dependent collimation behavior in far-field radiation patterns. The modal dispersion of negative refraction results in strong group velocity modulation, and self-focusing and -defocusing behaviors are apparent from light extraction. This study further verifies experimental results by using theoretic calculations based on equifrequency contours.
DEMINERALIZER BUILDING,TRA608. CAMERA FACES EAST ALONG SOUTH WALL. INSTRUMENT PANEL ...
DEMINERALIZER BUILDING,TRA-608. CAMERA FACES EAST ALONG SOUTH WALL. INSTRUMENT PANEL BOARD IS IN RIGHT HALF OF VIEW, WITH FOUR PUMPS BEYOND. SMALLER PUMPS FILL DEMINERALIZED WATER TANK ON SOUTH SIDE OF BUILDING. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION PRINTED ON ORIGINAL NEGATIVE. INL NEGATIVE NO. 3997A. Unknown Photographer, 12/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Park, Jin Ha; Lee, Jong Seok; Nam, Sang Beom; Ju, Jin Wu
2016-01-01
Purpose Supraglottic airway devices have been widely utilized as an alternative to tracheal intubation in various clinical situations. The rotation technique has been proposed to improve the insertion success rate of supraglottic airways. However, the clinical efficacy of this technique remains uncertain as previous results have been inconsistent, depending on the variable evaluated. Materials and Methods We systematically searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials in April 2015 for randomized controlled trials that compared the rotation and standard techniques for inserting supraglottic airways. Results Thirteen randomized controlled trials (1505 patients, 753 with the rotation technique) were included. The success rate at the first attempt was significantly higher with the rotation technique than with the standard technique [relative risk (RR): 1.13; 95% confidence interval (CI): 1.05 to 1.23; p=0.002]. The rotation technique provided significantly higher overall success rates (RR: 1.06; 95% CI: 1.04 to 1.09; p<0.001). Device insertion was completed faster with the rotation technique (mean difference: -4.6 seconds; 95% CI: -7.37 to -1.74; p=0.002). The incidence of blood staining on the removed device (RR: 0.36; 95% CI: 0.27 to 0.47; p<0.001) was significantly lower with the rotation technique. Conclusion The rotation technique provided higher first-attempt and overall success rates, faster insertion, and a lower incidence of blood on the removed device, reflecting less mucosal trauma. Thus, it may be considered as an alternative to the standard technique when predicting or encountering difficulty in inserting supraglottic airways. PMID:27189296
Naproxen Sodium for Pain Control With Intrauterine Device Insertion: A Randomized Controlled Trial.
Ngo, Lynn L; Braaten, Kari P; Eichen, Eva; Fortin, Jennifer; Maurer, Rie; Goldberg, Alisa B
2016-12-01
To evaluate whether 550 mg oral naproxen sodium given 1 hour before intrauterine device (IUD) insertion is effective for pain relief as compared with placebo. This was a randomized, double-blind, placebo-controlled trial. The primary outcome was pain with IUD insertion measured on a 100-mm visual analog scale (VAS). Our sample size was calculated to detect a 15-mm difference in VAS scores with 80% power (α=0.05). Secondary outcomes included pain with tenaculum placement, uterine sounding, and 5 and 15 minutes postinsertion. A total of 118 women were enrolled and analyzed (58 in the naproxen sodium arm, 60 in the placebo arm, 97% nulliparous) between May 11, 2015, and March 25, 2016. There were no differences in baseline demographics or reproductive characteristics between arms. There were no differences in median VAS pain scores for the primary outcome of pain with IUD insertion between the naproxen sodium arm compared with the placebo arm (69 compared with 66 mm, P=.89). There were no differences in the secondary outcomes of median VAS pain scores with tenaculum placement (37 compared with 32 mm, P=.97) or uterine sounding (60 compared with 58 mm, P=.66). However, median pain scores postprocedure were lower in the naproxen arm as compared with the placebo arm: 17 compared with 26 mm (P=.01) at 5 minutes and 13 compared with 24 mm (P=.01) at 15 minutes postinsertion. Oral naproxen sodium does not reduce pain with IUD insertion but does reduce pain after insertion and should be considered as a premedication. ClinicalTrials.gov, http://clinicaltrials.gov, NCT02388191.
Grentzer, Jaclyn M; Peipert, Jeffrey F; Zhao, Qiuhong; McNicholas, Colleen; Secura, Gina M; Madden, Tessa
2015-10-01
The objective was to compare three strategies for Chlamydia trachomatis and Neisseria gonorrhoeae screening prior to intrauterine device (IUD) insertion. This was a secondary analysis of the Contraceptive CHOICE Project. We measured the prevalence of C. trachomatis and/or N. gonorrhoeae at the time of IUD insertion. We then compared sensitivity, specificity, negative and positive predictive values, and likelihood ratios for three screening strategies for C. trachomatis and N. gonorrhoeae prior to IUD insertion: (a) "age-based" — age ≤25 years alone; (b) "age/partner-based" — age ≤25 and/or multiple sexual partners; and (c) "risk-based" — age ≤25, multiple sexual partners, inconsistent condom use and/or history of prior sexually transmitted infection (STI). Among 5087 IUD users, 140 (2.8%) tested positive for C. trachomatis, 16 (0.3%) tested positive for N. gonorrhoeae, and 6 (0.1%) were positive for both at the time of IUD insertion. The "risk-based" screening strategy had the highest sensitivity (99.3%) compared to "age-based" and "age/partner-based" screening (80.7% and 84.7%, respectively.) Only one (0.7%) woman with a chlamydia or gonorrhea infection would not have been screened using "risk-based" screening. A risk-based strategy to screen for C. trachomatis and N. gonorrhoeae prior to IUD insertion has higher sensitivity than screening based on age alone or age and multiple sexual partners. Using a risk-based screening strategy (age≤25, multiple sexual partners, inconsistent condom use and/or history of an STI) to determine who should be screened for C. trachomatis and N. gonorrhoeae prior to IUD insertion will miss very few cases of infection and obviates the need for universal screening. Copyright © 2015 Elsevier Inc. All rights reserved.
Furusho, Junji; Kobayashi, Hiroshi; Kikuchi, Takehito; Yamamoto, Tatsuro; Tanaka, Hidekazu; Terayama, Motokazu; Monden, Morito
2008-01-01
The purpose of this study is to realize the mechanically-controllable needle-insertion system using the CMTD (Curved Multi-Tube Device) which was developed by Furusho Laboratory. A CMTD, was developed for minimally-invasive surgery and needle insertion. And we use ultrasonograph as a sensing device to detect the position of bible duct or tumor and the orientation and position of the needle which is inserted into liver. This system makes safe minimally-invasive surgery possible, because all complex mechanisms are arranged outside of the body.
Ex vivo rabbit cornea diffusion studies with a soluble insert of moxifloxacin.
Sebastián-Morelló, María; Calatayud-Pascual, María Aracely; Rodilla, Vicent; Balaguer-Fernández, Cristina; López-Castellano, Alicia
2018-02-01
The objective of this research was to develop and evaluate an ocular insert for the controlled drug delivery of moxifloxacin which could perhaps be used in the treatment of corneal keratitis or even bacterial endophthalmitis. We have evaluated the ex vivo ocular diffusion of moxifloxacin through rabbit cornea, both fresh and preserved under different conditions. Histological studies were also carried out. Subsequently, drug matrix inserts were prepared using bioadhesive polymers. The inserts were evaluated for their physicochemical parameters. Ophthalmic ex vivo permeation of moxifloxacin was carried out with the most promising insert. The formulate insert was thin and provided higher ocular diffusion than commercial formulations. Ocular diffusion studies revealed significant differences between fresh and frozen corneas. Histological examinations also showed differences in the thickness of stroma between fresh and frozen corneas. The ophthalmic insert we have developed allows a larger quantity of moxifloxacin to permeate through the cornea than existing commercial formulations of the drug. Ocular delivery of moxifloxacin with this insert could be a new approach for the treatment of eye diseases.
Katalinic, Andrej; Trinajstic Zrinski, Magda; Roksandic Vrancic, Zlatka; Spalj, Stjepan
2017-02-01
The study focused on the influence of screwdriver design in combination with and without predrilling a pilot hole of inner implant diameter on insertion torque of orthodontic mini-implants, controlling for cortical thickness and vertical insertion force as cofactors. One hundred twenty mini-implants (Forestadent) of 1.7 mm in diameter and 6 and 8 mm in length were manually inserted into 120 swine rib bone samples. Maximal insertion torque as a measure of primary stability and vertical force were measured. The study included procedures with and without pilot hole and different screwdriver handles and shaft length and 2 implant lengths. Design of manual screwdriver does not modify insertion torque to a significant extent. In multiple linear regression model, significant predictors of insertion torque are thicker cortical bone (explaining 16.6% of variability), higher vertical force at maximal torque (13.5%), 6-mm implant length (2.5%), and the presence of pilot hole (2.3%). Handle type and shaft length of manual screwdriver do not significantly influence insertion torque, whereas predrilling a pilot hole has low impact on torque values of manually inserted self-drilling orthodontic mini-implants.
Improved efficiency of nanoneedle insertion by modification with a cell-puncturing protein
NASA Astrophysics Data System (ADS)
Ryu, Seunghwan; Matsumoto, Yuta; Matsumoto, Takahiro; Ueno, Takafumi; Silberberg, Yaron R.; Nakamura, Chikashi
2018-03-01
An atomic force microscope (AFM) probe etched into an ultra-sharp cylindrical shape (a nanoneedle) can be inserted into a living cell and mechanical responses of the insertion process are represented as force-distance curves using AFM. A probe-molecule-functionalized nanoneedle can be used to detect intracellular molecules of interest in situ. The insertion efficiencies of nanoneedles vary among cell types due to the cortex structures of cells, and some cell types, such as mouse fibroblast Balb/3T3 cells, show extremely low efficacy of insertion. We addressed this issue by using a cell membrane puncturing protein from bacteriophage T4 (gp5), a needle-like protein that spontaneously penetrates through the cell membrane. Gp5 was immobilized onto a nanoneedle surface. The insertion efficiency of the functionalized nanoneedle increased by over 15% compared to the non-functionalized control. Gp5-modification is a versatile approach in cell manipulation techniques for the insertion of other types of nanostructures into cells.
Breaking the regioselectivity rule for acrylate insertion in the Mizoroki-Heck reaction.
Wucher, Philipp; Caporaso, Lucia; Roesle, Philipp; Ragone, Francesco; Cavallo, Luigi; Mecking, Stefan; Göttker-Schnetmann, Inigo
2011-05-31
In modern methods for the preparation of small molecules and polymers, the insertion of substrate carbon-carbon double bonds into metal-carbon bonds is a fundamental step of paramount importance. This issue is illustrated by Mizoroki-Heck coupling as the most prominent example in organic synthesis and also by catalytic insertion polymerization. For unsymmetric substrates H(2)C = CHX the regioselectivity of insertion is decisive for the nature of the product formed. Electron-deficient olefins insert selectively in a 2,1-fashion for electronic reasons. A means for controlling this regioselectivity is lacking to date. In a combined experimental and theoretical study, we now report that, by destabilizing the transition state of 2,1-insertion via steric interactions, the regioselectivity of methyl acrylate insertion into palladium-methyl and phenyl bonds can be inverted entirely to yield the opposite "regioirregular" products in stoichiometric reactions. Insights from these experiments will aid the rational design of complexes which enable a catalytic and regioirregular Mizoroki-Heck reaction of electron-deficient olefins.
Nakata, Kensuke
2017-11-01
Some male spiders exhibit female genital mutilation behaviour (FGM) by removing the female genital appendage (scape) to control the mating frequency of females. Female spiders have two, i.e. right and left, genital openings connected with separate spermathecae into which males transfer sperm successively using one pedipalp (secondary genitalia) at a time. Thus, males must complete at least two palpal insertions to fill both spermathecae, before FGM. The present study examined whether (i) scape removal is only associated with the second palpal insertion (one-action hypothesis) or (ii) two contralateral palpal insertions facilitate FGM, with each insertion cutting the basal part of the scape halfway (two-actions hypothesis). Experiments in which females were replaced after a male had made the first insertion did not support the one-action hypothesis, because scapes remained intact after the newly introduced virgin females received their first palpal insertion, which was the second insertion by the males. In comparison, mating experiments using two half-eunuchs (i.e. one of the palps of each male had been manually removed, forcing them to fill female spermatheca on one side only) supported the two-actions hypothesis. FGM was more frequent in females that received two contralateral palpal insertions than in females that received ipsilateral insertions.
2017-01-01
Some male spiders exhibit female genital mutilation behaviour (FGM) by removing the female genital appendage (scape) to control the mating frequency of females. Female spiders have two, i.e. right and left, genital openings connected with separate spermathecae into which males transfer sperm successively using one pedipalp (secondary genitalia) at a time. Thus, males must complete at least two palpal insertions to fill both spermathecae, before FGM. The present study examined whether (i) scape removal is only associated with the second palpal insertion (one-action hypothesis) or (ii) two contralateral palpal insertions facilitate FGM, with each insertion cutting the basal part of the scape halfway (two-actions hypothesis). Experiments in which females were replaced after a male had made the first insertion did not support the one-action hypothesis, because scapes remained intact after the newly introduced virgin females received their first palpal insertion, which was the second insertion by the males. In comparison, mating experiments using two half-eunuchs (i.e. one of the palps of each male had been manually removed, forcing them to fill female spermatheca on one side only) supported the two-actions hypothesis. FGM was more frequent in females that received two contralateral palpal insertions than in females that received ipsilateral insertions. PMID:29291078
Elbay, M; Şermet Elbay, Ü; Yıldırım, S; Uğurluel, C; Kaya, C; Baydemir, C
2015-06-01
To compare paediatric patients' pain during needle insertion and injection in inferior alveoler nerve block (IANB) anaesthesia injected by either a traditional syringe (TS) or the DentalVibe Injection Comfort System (DV). the study was a randomised controlled crossover clinical trial, comprised of 60 children aged 6-12 requiring an operative procedure with IANB anaesthesia on their mandibular molars bilaterally. One of the molar teeth was treated with TS and the contralateral tooth was treated with DV. On each visit, subjective and objective pain was evaluated using the Wond-Baker Faces Pain Rating Scale (PRS) and the Face, Legg, Cry, Consolability Scale (FLACC Scale). Patients were asked which anaesthesia technique they preferred. Data were analysed using Wilcoxon signed rank, Spearman correlation, and Mann-Whitney U tests. There were no statistically significant differences for pain evalution during needle insertion and injection of each injection system. However, a negative correlation was found on the FLACC between age and pain scores during injection after using DV. Paediatric patients experienced similar pain during IANB anaesthesia administered with TS and DV. With increased age, pain values reduced during anaesthetic agent injection with DV according to FLACC. The traditional procedure was preferred to DV in paediatric patients.
Goold, Hugh Douglas; Nguyen, Hoa Mai; Kong, Fantao; Beyly-Adriano, Audrey; Légeret, Bertrand; Billon, Emmanuelle; Cuiné, Stéphan; Beisson, Fred; Peltier, Gilles; Li-Beisson, Yonghua
2016-01-01
Microalgae have emerged as a promising source for biofuel production. Massive oil and starch accumulation in microalgae is possible, but occurs mostly when biomass growth is impaired. The molecular networks underlying the negative correlation between growth and reserve formation are not known. Thus isolation of strains capable of accumulating carbon reserves during optimal growth would be highly desirable. To this end, we screened an insertional mutant library of Chlamydomonas reinhardtii for alterations in oil content. A mutant accumulating five times more oil and twice more starch than wild-type during optimal growth was isolated and named constitutive oil accumulator 1 (coa1). Growth in photobioreactors under highly controlled conditions revealed that the increase in oil and starch content in coa1 was dependent on light intensity. Genetic analysis and DNA hybridization pointed to a single insertional event responsible for the phenotype. Whole genome re-sequencing identified in coa1 a >200 kb deletion on chromosome 14 containing 41 genes. This study demonstrates that, 1), the generation of algal strains accumulating higher reserve amount without compromising biomass accumulation is feasible; 2), light is an important parameter in phenotypic analysis; and 3), a chromosomal region (Quantitative Trait Locus) acts as suppressor of carbon reserve accumulation during optimal growth. PMID:27141848
Dragovic, A S; Stringer, A K; Campbell, L; Shaul, C; O'Leary, S J; Briggs, R J
2018-05-01
To investigate the clinical usefulness and practicality of co-registration of Cone Beam CT (CBCT) with preoperative Magnetic Resonance Imaging (MRI) for intracochlear localization of electrodes after cochlear implantation. Images of 20 adult patients who underwent CBCT after implantation were co-registered with preoperative MRI scans. Time taken for co-registration was recorded. The images were analysed by clinicians of varying levels of expertise to determine electrode position and ease of interpretation. After a short learning curve, the average co-registration time was 10.78 minutes (StdDev 2.37). All clinicians found the co-registered images easier to interpret than CBCT alone. The mean concordance of CBCT vs. co-registered image analysis between consultant otologists was 60% (17-100%) and 86% (60-100%), respectively. The sensitivity and specificity for CBCT to identify Scala Vestibuli insertion or translocation was 100 and 75%, respectively. The negative predictive value was 100%. CBCT should be performed following adult cochlear implantation for audit and quality control of surgical technique. If SV insertion or translocation is suspected, co-registration with preoperative MRI should be performed to enable easier analysis. There will be a learning curve for this process in terms of both the co-registration and the interpretation of images by clinicians.
Site-controlled GaN nanocolumns with InGaN insertions grown by MBE
NASA Astrophysics Data System (ADS)
Nechaev, D. V.; Semenov, A. N.; Koshelev, O. A.; Jmerik, V. N.; Davydov, V. Yu; Smirnov, A. N.; Pozina, G.; Shubina, T. V.; Ivanov, S. V.
2017-11-01
The site-controlled plasma-assisted molecular beam epitaxy (PA MBE) has been developed to fabricate the regular array of GaN nanocolumns (NCs) with InGaN insertions on micro-cone patterned sapphire substrates (μ-CPSSs). Two-stage growth of GaN NCs, including a nucleation layer grown at metal-rich conditions and high temperature GaN growth in strong N-rich condition, has been developed to achieve the selective growth of the NCs. Microcathodoluminescence measurements have demonstrated pronounced emission from the InGaN insertions in 450-600 nm spectral range. The optically isolated NCs can be used as effective nano-emitters operating in the visible range.
Ivanov, Vadim A
2016-02-01
The reduction of instrumental dead space is a recognized approach to preventing ventilation-induced lung injury in premature infants. However, there are no published data regarding the effectiveness of instrumental dead-space reduction in endotracheal tube (ETT) connectors. We tested the impact of the Y-piece/ETT connector pairs with reduced instrumental dead space on CO2 elimination in a model of the premature neonate lung. The standard ETT connector was compared with a low-dead-space ETT connector and with a standard connector equipped with an insert. We compared the setups by measuring the CO2 elimination rate in an artificial lung ventilated via the connectors. The lung was connected to a ventilator via a standard circuit, a 2.5-mm ETT, and one of the connectors under investigation. The ventilator was run in volume-controlled continuous mandatory ventilation mode. The low-dead-space ETT connector/Y-piece and insert-equipped standard connector/Y-piece pairs had instrumental dead space reduced by 36 and 67%, respectively. With set tidal volumes (VT) of 2.5, 5, and 10 mL, in comparison with the standard ETT connector, the low-dead-space connector reduced CO2 elimination time by 4.5% (P < .05), 4.4% (P < .01), and 7.1% (not significant), respectively. The insert-equipped standard connector reduced CO2 elimination time by 13.5, 25.1, and 16.1% (all P < .01). The low-dead-space connector increased inspiratory resistance by 17.8% (P < .01), 9.6% (P < .05), and 5.0% (not significant); the insert-equipped standard connector increased inspiratory resistance by 9.1, 8.4, and 5.9% (all not significant). The low-dead-space connector decreased expiratory resistance by 6.8% (P < .01) and 1.8% (not significant) and increased it by 1.4% (not significant); the insert-equipped standard connector decreased expiratory resistance by 1.5 and 1% and increased it by 1% (all not significant). The low-dead-space connector increased work of breathing by 4.7% (P < .01), 3.8% (P < .01), and 2.5% (not significant); the insert-equipped standard connector increased it by 0.8% (not significant), 2.5% (P < .01), and 2.8% (P < .01). Both methods of instrumental dead-space reduction led to improvements in artificial lung ventilation. Negative effects on resistance and work of breathing appeared minimal. Further testing in vivo should be performed to confirm the lung model results and, if successful, translated into clinical practice. Copyright © 2016 by Daedalus Enterprises.
Sinkin, Joshua A; Craig, Wendy Y; Jones, Michael; Pinette, Michael G; Wax, Joseph R
2018-02-01
To evaluate perinatal outcomes in singleton and twin pregnancies with pathologically confirmed velamentous cord insertion without vasa previa. This retrospective case-control study included all nonanomalous singleton and twin pregnancies with pathologically confirmed velamentous cord insertion delivered in a single institution between January 1, 2005, and July 1, 2015, and having an ultrasound examination by maternal-fetal medicine. For each case, the next 2 consecutive deliveries matched for gestational age at delivery ± 1 week and, in twins, amnionicity and chorionicity served as controls. Primary outcomes included surgical delivery for a nonreassuring intrapartum fetal heart rate tracing, umbilical arterial cord pH of less than 7.2, 5-minute Apgar score of less than 7, birth weight below the 10th percentile, neonatal intensive care unit admission, fetal or neonatal death, and cord avulsion necessitating manual placental extraction. Outcomes were available for 53 singletons with 103 matched controls and 33 twin pregnancies with 65 matched controls. In singletons, velamentous cord insertion was associated with cord pH of less than 7.2 (odds ratio [OR] 3.5; 95% confidence interval [CI], 1.1-11.2; P = .039), 5-minute Apgar score of less than 7 (OR, 5.3; 95% CI, 0.99-28.1; P = .045), and cord avulsion requiring manual placental extraction (7.5% versus 0%; P = .012). Associations were suggested with increased surgical delivery for a nonreassuring intrapartum fetal heart rate tracing (OR, 2.4; 95% CI, 0.9-6.9; P = .14), birth weight below the 10th percentile (OR, 2.1; 95% CI, 0.8-5.9; P = .21), and fetal or neonatal death (3.8% versus 0%; P = .11). Velamentous cord insertions were also associated with placental abruption in singletons (7.5% versus 0%; P = .013). Among twins, velamentous cord insertion was associated with fetal or neonatal death (9.1% versus 0%; P = .036). Isolated confirmed velamentous cord insertion is associated with adverse perinatal outcomes in singleton and twin gestations. © 2017 by the American Institute of Ultrasound in Medicine.
Program Aids In Printing FORTRAN-Coded Output
NASA Technical Reports Server (NTRS)
Akian, Richard A.
1993-01-01
FORPRINT computer program prints FORTRAN-coded output files on most non-Postscript printers with such extra features as control of fonts for Epson and Hewlett Packard printers. Rewrites data to printer and inserts correct printer-control codes. Alternative uses include ability to separate data or ASCII file during printing by use of editing software to insert "1" in first column of data line that starts new page. Written in FORTRAN 77.
Chowdhary, Ramesh; Jimbo, Ryo; Thomsen, Christian; Carlsson, Lennart; Wennerberg, Ann
2013-03-01
To investigate the combined effect of macro and pitch shortened threads on primary and secondary stability during healing, but before dynamic loading. Two sets of turned implants with different macro geometry were prepared. The test group possessed pitch shortened threads in between the large threads and the control group did not have thread alterations. The two implant groups were placed in both femur and tibiae of 10 lop-eared rabbits, and at the time of implant insertion, insertion torques were recorded. After 4 weeks, all implants were subjected to removal torque tests. The insertion torque values for the control and test groups for the tibia were 15.7 and 20.6 Ncm, respectively, and for the femur, 11.8, and 12.8 Ncm respectively. The removal torque values for the control and test groups in the tibia were 7.9 and 9.1 Ncm, respectively, and for the femur, 7.9 and 7.7 Ncm respectively. There was no statistically significant difference between the control and test groups. Under limited dynamic load, the addition of pitch shortened threads did not significantly improve either the primary or the secondary stability of the implants in bone. © 2011 John Wiley & Sons A/S.
Turbine airfoil having near-wall cooling insert
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Jr., Nicholas F.; Wiebe, David J.
A turbine airfoil is provided with at least one insert positioned in a cavity in an airfoil interior. The insert extends along a span-wise extent of the turbine airfoil and includes first and second opposite faces. A first near-wall cooling channel is defined between the first face and a pressure sidewall of an airfoil outer wall. A second near-wall cooling channel is defined between the second face and a suction sidewall of the airfoil outer wall. The insert is configured to occupy an inactive volume in the airfoil interior so as to displace a coolant flow in the cavity towardmore » the first and second near-wall cooling channels. A locating feature engages the insert with the outer wall for supporting the insert in position. The locating feature is configured to control flow of the coolant through the first or second near-wall cooling channel.« less
Schneck, Felix; Ahrens, Jennifer; Finger, Markus; Stückl, A Claudia; Würtele, Christian; Schwarzer, Dirk; Schneider, Sven
2018-03-21
Direct hydrogenation of CO 2 to CO, the reverse water-gas shift reaction, is an attractive route to CO 2 utilization. However, the use of molecular catalysts is impeded by the general reactivity of metal hydrides with CO 2 . Insertion into M-H bonds results in formates (MO(O)CH), whereas the abnormal insertion to the hydroxycarbonyl isomer (MC(O)OH), which is the key intermediate for CO-selective catalysis, has never been directly observed. We here report that the selectivity of CO 2 insertion into a Ni-H bond can be inverted from normal to abnormal insertion upon switching from thermal to photochemical conditions. Mechanistic examination for abnormal insertion indicates photochemical N-H reductive elimination as the pivotal step that leads to an umpolung of the hydride ligand. This study conceptually introduces metal-ligand cooperation for selectivity control in photochemical transformations.
Complicating Gert Biesta's Account of Subjectification: ŽIžekian Negativity and Buddhist "SuNyata"
ERIC Educational Resources Information Center
Oral, Sevket Benhur
2016-01-01
Biesta identifies three functions that educational systems perform: qualification, socialization, and subjectification. Subjectification involves ways of being whereby individuals exercise their capacity to remain independent from the existing orders by challenging their uncontested insertion into these orders. For Biesta, becoming a subject…
Controlling Posture and Vergence Eye Movements in Quiet Stance: Effects of Thin Plantar Inserts
Foisy, A.; Gaertner, C.; Matheron, E.; Kapoula, Z.
2015-01-01
The purpose of this study was to assess properties of vergence and saccade eye movements as well as posture in quiet stance, and the effects of thin plantar inserts upon postural and oculomotor control. The performances of 36 young healthy subjects were recorded by a force platform and an eye tracker in three testing conditions: without plantar stimulation, with a 3 millimetre-thick plantar insert, either a Medial or a Lateral Arch Support (MAS / LAS). The results showed a decrease of the Surface and Variance of Speed and a more posterior position of the CoP with either stimulation compared with the control condition. The fractal analysis showed a decrease with MAS. Wavelet analysis in the time-frequency domain revealed an increase in the Cancelling Time of the low frequency band with MAS. These results suggest a better stability for a lower energy cost. Concerning eye movements, the inserts influenced only vergence (not saccades): MAS caused an increase of the phasic amplitude of divergence, and conversely a decrease of the tonic amplitude. In contrast, LAS caused an increase of the tonic amplitude of convergence. Thus, MAS renders divergence less visually driven, while LAS renders convergence more visually driven. We conclude that the CNS uses the podal signal for both postural and vergence control via specific mechanisms. Plantar inserts have an influence upon posture and vergence movements in a different way according to the part of the foot sole being stimulated. These results can be useful to clinicians interested in foot or eye. PMID:26637132
2009-01-01
Background Insertional mutagenesis is an effective method for functional genomic studies in various organisms. It can rapidly generate easily tractable mutations. A large-scale insertional mutagenesis with the piggyBac (PB) transposon is currently performed in mice at the Institute of Developmental Biology and Molecular Medicine (IDM), Fudan University in Shanghai, China. This project is carried out via collaborations among multiple groups overseeing interconnected experimental steps and generates a large volume of experimental data continuously. Therefore, the project calls for an efficient database system for recording, management, statistical analysis, and information exchange. Results This paper presents a database application called MP-PBmice (insertional mutation mapping system of PB Mutagenesis Information Center), which is developed to serve the on-going large-scale PB insertional mutagenesis project. A lightweight enterprise-level development framework Struts-Spring-Hibernate is used here to ensure constructive and flexible support to the application. The MP-PBmice database system has three major features: strict access-control, efficient workflow control, and good expandability. It supports the collaboration among different groups that enter data and exchange information on daily basis, and is capable of providing real time progress reports for the whole project. MP-PBmice can be easily adapted for other large-scale insertional mutation mapping projects and the source code of this software is freely available at http://www.idmshanghai.cn/PBmice. Conclusion MP-PBmice is a web-based application for large-scale insertional mutation mapping onto the mouse genome, implemented with the widely used framework Struts-Spring-Hibernate. This system is already in use by the on-going genome-wide PB insertional mutation mapping project at IDM, Fudan University. PMID:19958505
Improving Robotic Operator Performance Using Augmented Reality
NASA Technical Reports Server (NTRS)
Maida, James C.; Bowen, Charles K.; Pace, John W.
2007-01-01
The Special Purpose Dexterous Manipulator (SPDM) is a two-armed robot that functions as an extension to the end effector of the Space Station Robotics Manipulator System (SSRMS), currently in use on the International Space Station (ISS). Crew training for the SPDM is accomplished using a robotic hardware simulator, which performs most of SPDM functions under normal static Earth gravitational forces. Both the simulator and SPDM are controlled from a standard robotic workstation using a laptop for the user interface and three monitors for camera views. Most operations anticipated for the SPDM involve the manipulation, insertion, and removal of any of several types of Orbital Replaceable Unit (ORU), modules which control various ISS functions. Alignment tolerances for insertion of the ORU into its receptacle are 0.25 inch and 0.5 degree from nominal values. The pre-insertion alignment task must be performed within these tolerances by using available video camera views of the intrinsic features of the ORU and receptacle, without special registration markings. Since optimum camera views may not be available, and dynamic orbital lighting conditions may limit periods of viewing, a successful ORU insertion operation may require an extended period of time. This study explored the feasibility of using augmented reality (AR) to assist SPDM operations. Geometric graphical symbols were overlaid on one of the workstation monitors to afford cues to assist the operator in attaining adequate pre-insertion ORU alignment. Twelve skilled subjects performed eight ORU insertion tasks using the simulator with and without the AR symbols in a repeated measures experimental design. Results indicated that using the AR symbols reduced pre-insertion alignment error for all subjects and reduced the time to complete pre-insertion alignment for most subjects.
Zhu, Yue-Qi; Edmonds, Laura; Wei, Li-Ming; Zheng, Rei-La; Cheng, Ruo-Yu; Cui, Wen-Guo; Cheng, Ying-Sheng
2017-06-01
Determine the feasibility of and tissue response to biodegradable magnesium-silicone stent insertion into the oesophagus of rabbits. Mechanical compression-recovery and degradation behaviours of the stents were investigated in vitro. Thirty rabbits were randomly divided into a magnesium-silicone stent group (n = 15) that received stent insertion into the lower 1/3 of the oesophagus under fluoroscopic guidance and a control group (n = 15). Oesophagography was performed at 1, 2 and 4 weeks. Five rabbits in each group were euthanized at each time point for histological examination. Magnesium-silicone stents showed good flexibility and elasticity, and degraded more slowly than bare stents at pH 4.0 and 7.4. All stent insertions were well tolerated. The oesophageal diameters at 1, 2 and 4 weeks were 9.7 ± 0.7, 9.6 ± 0.8 and 9.6 ± 0.5 mm, respectively (vs. 9.2 ± 0.8 mm before intervention; P > 0.05). Stent migration occurred in six rabbits (one at 1 week, one at 2 and four at 4). Microscopy demonstrated dilation of the oesophageal wall within 1 week of insertion. Oesophageal injury and collagen deposition following stent insertion were similar to control (P > 0.05). Oesophageal magnesium-silicone stent insertion was feasible and provided reliable support for 2 weeks without causing oesophageal injury or collagen deposition. • Mg stent provided apparently adequate radial force and silicone membrane reduced magnesium biodegradation • Stent insertion provided good support for at least 2 weeks before biodegradation • Stenting effectively resulted in oesophageal wall remodelling, without demonstrable injury.
PULPAL BLOOD FLOW CHANGES IN ABUTMENT TEETH OF REMOVABLE PARTIAL DENTURES
Kunt, Göknil Ergün; Kökçü, Deniz; Ceylan, Gözlem; Yılmaz, Nergiz; Güler, Ahmet Umut
2009-01-01
The purpose of this study was to investigate the effect of tooth supported (TSD) and toothtissue supported (TTSD) removable partial denture wearing on pulpal blood flow (PBF) of the abutment teeth by using Laser Doppler Flowmeter (LDF). Measurements were carried out on 60 teeth of 28 patients (28 teeth and 12 patients of TTSD group, 32 teeth and 16 patients of TSD group) who had not worn any type of removable partial dentures before, had no systemic problems and were non smokers. PBF values were recorded by LDF before insertion (day 0) and after insertion of dentures at day 1, day 7 and day 30. Statistical analysis was performed by student t test and covariance analyses of repeated measurements. In the group TTSD, the mean values of PBF decreased statistically significantly at day 1 after insertion when compared with PBF values before insertion (p<0,01). There was no statistically significant difference among PBF mean values on 1st, 7th and 30th day. However, in the group TSD, there was no statistically significant difference among PBF mean values before insertion and on 1st, 7th and 30th day. In other words, PBF mean values in group TSD continued without changing statistically significant on 1st, 7th and 30th day. TTSD wearing may show negative effect on the abutment teeth due to decreasing basal PBF. PMID:20001995
Vachhani, Raj; Patel, Toral; Centor, Robert M; Estrada, Carlos A
2017-01-01
Meta-analyses based on peer-reviewed publications report a sensitivity of approximately 85% for rapid antigen streptococcus tests to diagnose group A streptococcal (GAS) pharyngitis. Because these meta-analyses excluded package inserts, we examined the test characteristics of rapid antigen streptococcal tests and molecular methods that manufacturers report in their package inserts. We included tests available in the US market (Food and Drug Administration, period searched 1993-2015) and used package insert data to calculate pooled sensitivity and specificity. To examine quality, we used the Quality Assessment of Diagnostic Accuracy Studies-2. We excluded 26 tests having different trade names but identical methods and data. The study design was prospective in 41.7% (10 of 24). The pooled sensitivity of the most commonly used method, lateral flow/immunochromatographic, was 95% (95% confidence interval [CI] 94-96) and the pooled specificity was 98% (96-98); 7108 patients. The pooled sensitivity of the polymerase chain reaction or molecular methods was 98% (95% CI 96-98) and the pooled specificity was 96% (95% CI 95-97); 5685 patients. Package inserts include sponsored studies that overestimate the sensitivity of rapid tests to diagnose GAS pharyngitis by approximately 10%. Physicians should understand that package inserts overestimate diagnostic test utility; a negative test cannot be used to exclude GAS pharyngitis.
Briggs, R J; Tykocinski, M; Saunders, E; Hellier, W; Dahm, M; Pyman, B; Clark, G M
2001-09-01
To review the mechanisms and nature of intracochlear damage associated with cochlear implant electrode array insertion, in particular, the various perimodiolar electrode designs. Make recommendations regarding surgical techniques for the Nucleus Contour electrode to ensure correct position and minimal insertion trauma. The potential advantages of increased modiolar proximity of intracochlear multichannel electrode arrays are a reduction in stimulation thresholds, an increase in dynamic range and more localized neural excitation. This may improve speech perception and reduce power consumption. These advantages may be negated if increased intracochlear damage results from the method used to position the electrodes close to the modiolus. A review of the University of Melbourne Department of Otolaryngology experience with temporal bone safety studies using the Nucleus standard straight electrode array and a variety of perimodiolar electrode array designs; comparison with temporal bone insertion studies from other centres and postmortem histopathology studies reported in the literature. Review of our initial clinical experience using the Nucleus Contour electrode array. The nature of intracochlear damage resulting from electrode insertion trauma ranges from minor, localized, spiral ligament tear to diffuse organ of Corti disruption and osseous spiral lamina fracture. The type of damage depends on the mechanical characteristics of the electrode array, the stiffness, curvature and size of the electrode in relation to the scala, and the surgical technique. The narrow, flexible, straight arrays are the least traumatic. Pre-curved or stiffer arrays are associated with an incidence of basilar membrane perforation. The cochleostomy must be correctly sited in relation to the round window to ensure scala tympani insertion. A cochleostomy anterior to the round window rather than inferior may lead to scala media or scala vestibuli insertion. Proximity of electrodes to the modiolus can be achieved without intracochlear damage provided the electrode array is a free fit within the scala, of appropriate size and shape, and accurate scala tympani insertion is performed.
Effect of insertion torque on titanium implant osseointegration: an animal experimental study.
Duyck, Joke; Roesems, Rutger; Cardoso, Marcio V; Ogawa, Toru; De Villa Camargos, Germana; Vandamme, Katleen
2015-02-01
To evaluate the effect of implant insertion torque on the peri-implant bone healing and implant osseointegration. Bilaterally in the tibia of five adult New Zealand white rabbits, 20 implants were installed, subdivided into four groups, corresponding to two insertion torque conditions (low, < 10 Ncm vs. high > 50 Ncm) and 2 experimental periods (2 weeks vs. 4 weeks of healing). The implant insertion torque was determined by the surgical drill diameter relative to the implant diameter. Implant osseointegration was evaluated by quantitative histology (bone-to-implant contact with host bone [BIC-host], with neoformed bone [BIC-de novo], with both bone types [BIC-total], and peri-implant bone [BA/TA]). Every response was modelled over time using GEE (general estimation equation) with an unstructured variance-covariance matrix to correct for dependency between the measurements from one animal. The statistical significance level of α = 0.05 was applied. Significantly, more BIC-host and BIC-total were recorded for H implants compared with L implants after 2 week of healing (P = 0.010 and P = 0.0001, respectively). However, this result was no longer found for the extended healing period. Furthermore, BIC-total significantly increased over time for L implants (P < 0.00001). In contrast, the significant increase in BA/TA over time was found for H implants (P < 0.01). Finally, H insertion torque led to an increased BA/TA after 4 week of healing (P < 0.02) compared with the L insertion protocol. L insertion torque implants installed in the rabbit tibial bone osseointegrate with considerable de novo bone formation. This bone neoformation enables L implants to catch up, already during the early osseointegration stage, the initial inferior amount BIC contact compared with that of H implants. A negative impact of the created strain environment accompanying H insertion torque implant installation on the biological process of osseointegration could not be observed, at least not at tissue level. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Mandaliti, Walter; Nepravishta, Ridvan; Sinibaldi Vallebona, Paola; Pica, Francesca; Garaci, Enrico; Paci, Maurizio
2016-03-15
Thymosin α1 is a peptidic hormone with pleiotropic activity and is used in the therapy of several diseases. It is unstructured in water solution and interacts with negative regions of vesicles by assuming two tracts of helical conformation with a structural break between them. This study reports on Thymosin α1's interaction with mixed phospholipids phosphatidylcholine and phosphatidylserine, the negative component of the membranes, by ¹H and natural abundance ¹⁵N nuclear magnetic resonance (NMR). The results indicate that interaction occurs when the membrane is negatively charged by exposing phosphatidylserine. Moreover, the direct interaction of Thymosin α1 with K562 cells with an overexposure of phosphatidylserine as a consequence of resveratrol-induced apoptosis was conducted. Thymosin α1's interaction with human serum albumin was also investigated by NMR spectroscopy. Steady-state saturation transfer, transfer nuclear Overhauser effect spectroscopy, and diffusion-ordered spectroscopy methodologies all reveal that the C-terminal region of Thymosin α1 is involved in the interaction with serum albumin. These results may shed more light on Thymosin α1's mechanism of action by its insertion in negative regions of membranes due to the exposure of phosphatidylserine. Once Thymosin α1's N-terminus has been inserted into the membrane, the rest may interact with nearby proteins and/or receptors acting as effectors and causing a biological signaling cascade, thus exerting thymosin α1's pleiotropy.
Boas, Wendell Vilas; Gonçalves, Rozana Oliveira; Costa, Olívia Lúcia Nunes; Goncalves, Marilda Souza
2015-02-01
To investigate the association between polymorphisms in genes that encode enzymes involved in folate- and vitamin B12-dependent homocysteine metabolism and recurrent spontaneous abortion (RSA). We investigated the C677T and A1298C polymorphisms of the methylenetetrahydrofalate reductase gene (MTHFR), the A2756G polymorphism of the methionine synthase gene (MS) and the 844ins68 insertion of the cystathionine beta synthetase gene (CBS). The PCR technique followed by RFLP was used to assess the polymorphisms; the serum levels of homocysteine, vitamin B12 and folate were investigated by chemiluminescence. The EPI Info Software version 6.04 was used for statistical analysis. Parametric variables were compared by Student's t-test and nonparametric variables by the Wilcoxon rank sum test. The frequencies of gene polymorphisms in 89 women with a history of idiopathic recurrent miscarriage and 150 controls were 19.1 and 19.6% for the C677T, insertion, 20.8 and 26% for the A1298C insertion, 14.2 and 21.9% for the A2756G insertion, and 16.4 and 18% for the 844ins68 insertion, respectively. There were no significant differences between case and control groups in any of the gene polymorphisms investigated. However, the frequency of the 844ins68 insertion in the CBS gene was higher among women with a history of loss during the third trimester of pregnancy (p=0.003). Serum homocysteine, vitamin B12 and folate levels id not differ between the polymorphisms studied in the case and control groups. However, linear regression analysis showed a dependence of serum folate levels on the maintenance of tHcy levels. The investigated gene polymorphisms and serum homocysteine, vitamin B12 and folate levels were not associated with idiopathic recurrent miscarriage in the present study. Further investigations are needed in order to confirm the role of the CBS 844ins68 insertion in recurrent miscarriage.
In vitro and in vivo mechanical stability of orthodontic mini-implants.
Cho, Il-Sik; Kim, Sung-Kyun; Chang, Young-Il; Baek, Seung-Hak
2012-07-01
To compare in vivo and in vitro mechanical stability of orthodontic mini-implants (OMIs) treated with a sandblasted, large-grit, and anodic-oxidation (SLAO) method vs those treated with a sandblasted, large-grit, and acid-etching (SLA) method. Fifty-four titanium OMIs (cylindrical shape, drill-free type; diameter = 1.45 mm, length = 8 mm, Biomaterials Korea Inc, Seoul, Korea) were allocated into control, SLA, and SLAO groups (N = 12 for in vivo and N = 6 for in vitro studies per group). In vitro study was carried out on a polyurethane foam bone block (Sawbones, Pacific Research Laboratories Inc, Vashon, Wash). In vivo study was performed in the tibias of Beagles (6 males, age = 1 year, weight = 10 to 13 kg; OMIs were removed at 8 weeks after installation). For insertion and removal of OMIs, the speed and maximum torque of the surgical engine were set to 30 rpm and 40 Ncm, respectively. Maximum torque (MT), total energy (TE), and near peak energy (NPE) during the insertion and removal procedures were statistically analyzed. In the in vitro study, although the control group had a higher insertion MT value than the SLA and SLAO groups (P < .01), no differences in insertion TE and NPE or in any of the removal variables were noted among the three groups. In the in vivo study, the control group exhibited higher values for all insertion variables compared with the SLA and SLAO groups (MT, P < .001; TE, P < .01; NPE, P < .001). Although no difference in removal TE and removal NPE was noted among the three groups, the SLAO group presented with a higher removal MT than the SLA and control groups (P < .001). SLAO treatment may be an effective tool in reducing insertion damage to surrounding tissue and improving the mechanical stability of OMIs.
Strain measurements of the tibial insert of a knee prosthesis using a knee motion simulator.
Sera, Toshihiro; Iwai, Yuya; Yamazaki, Takaharu; Tomita, Tetsuya; Yoshikawa, Hideki; Naito, Hisahi; Matsumoto, Takeshi; Tanaka, Masao
2017-12-01
The longevity of a knee prosthesis is influenced by the wear of the tibial insert due to its posture and movement. In this study, we assumed that the strain on the tibial insert is one of the main reasons for its wear and investigated the influence of the knee varus-valgus angles on the mechanical stress of the tibial insert. Knee prosthesis motion was simulated using a knee motion simulator based on a parallel-link six degrees-of-freedom actuator and the principal strain and pressure distribution of the tibial insert were measured. In particular, the early stance phase obtained from in vivo X-ray images was examined because the knee is applied to the largest load during extension/flexion movement. The knee varus-valgus angles were 0° (neutral alignment), 3°, and 5° malalignment. Under a neutral orientation, the pressure was higher at the middle and posterior condyles. The first and second principal strains were larger at the high and low pressure areas, respectively. Even for a 3° malalignment, the load was concentrated at one condyle and the positive first principal strain increased dramatically at the high pressure area. The negative second principal strain was large at the low pressure area on the other condyle. The maximum equivalent strain was 1.3-2.1 times larger at the high pressure area. For a 5° malalignment, the maximum equivalent strain increased slightly. These strain and pressure measurements can provide the mechanical stress of the tibial insert in detail for determining the longevity of an artificial knee joint.
Tietz, Andreas; Frei, Reno; Dangel, Marc; Bolliger, Dora; Passweg, Jakob R; Gratwohl, Alois; Widmer, Andreas E
2005-08-01
To determine the efficacy and tolerability of octenidine hydrochloride, a non-alcoholic skin antiseptic, for the care of central venous catheter (CVC) insertion sites. Prospective, observational study. Bone marrow transplantation unit of a university hospital. All consecutive patients with a nontunneled CVC were enrolled prospectively after informed consent. Octenidine hydrochloride (0.1%) was applied for disinfection at the CVC insertion site during dressing changes. The following cultures were performed weekly as well as at the occurrence of any systemic inflammatory response syndrome criteria: cultures of the skin surrounding the CVC entry site, cultures of the three-way hub connected to the CVC, blood cultures, and cultures of the CVC tip on removal. Enhanced microbiological methods (skin swabs of a 24-cm2 standardized area, roll plate, and sonication of catheter tips) were applied. One hundred thirty-five CVCs were inserted in 62 patients during the study period and remained for a mean period of 19.1 days, corresponding to 2,462 catheter-days. Bacterial density at the insertion site declined substantially over time, and most cultures became negative 2 weeks after insertion. Only 6 patients had a documented catheter-related bloodstream infection. The incidence density was 2.39 catheter infections per 1,000 catheter-days. No side effects were noted with application of the antiseptic. Disinfection with a skin antiseptic that contains octenidine hydrochloride is highly active and well tolerated. It leads to a decrease in skin colonization over time and may be a new option for CVC care.
Hiraki, Takao; Kamegawa, Tetsushi; Matsuno, Takayuki; Sakurai, Jun; Kirita, Yasuzo; Matsuura, Ryutaro; Yamaguchi, Takuya; Sasaki, Takanori; Mitsuhashi, Toshiharu; Komaki, Toshiyuki; Masaoka, Yoshihisa; Matsui, Yusuke; Fujiwara, Hiroyasu; Iguchi, Toshihiro; Gobara, Hideo; Kanazawa, Susumu
2017-11-01
Purpose To evaluate the accuracy of the remote-controlled robotic computed tomography (CT)-guided needle insertion in phantom and animal experiments. Materials and Methods In a phantom experiment, 18 robotic and manual insertions each were performed with 19-gauge needles by using CT fluoroscopic guidance for the evaluation of the equivalence of accuracy of insertion between the two groups with a 1.0-mm margin. Needle insertion time, CT fluoroscopy time, and radiation exposure were compared by using the Student t test. The animal experiments were approved by the institutional animal care and use committee. In the animal experiment, five robotic insertions each were attempted toward targets in the liver, kidneys, lungs, and hip muscle of three swine by using 19-gauge or 17-gauge needles and by using conventional CT guidance. The feasibility, safety, and accuracy of robotic insertion were evaluated. Results The mean accuracies of robotic and manual insertion in phantoms were 1.6 and 1.4 mm, respectively. The 95% confidence interval of the mean difference was -0.3 to 0.6 mm. There were no significant differences in needle insertion time, CT fluoroscopy time, or radiation exposure to the phantom between the two methods. Effective dose to the physician during robotic insertion was always 0 μSv, while that during manual insertion was 5.7 μSv on average (P < .001). Robotic insertion was feasible in the animals, with an overall mean accuracy of 3.2 mm and three minor procedure-related complications. Conclusion Robotic insertion exhibited equivalent accuracy as manual insertion in phantoms, without radiation exposure to the physician. It was also found to be accurate in an in vivo procedure in animals. © RSNA, 2017 Online supplemental material is available for this article.
Stacchi, Claudio; Vercellotti, Tomaso; Torelli, Lucio; Furlan, Fabio; Di Lenarda, Roberto
2013-04-01
The objective of the present investigation was to longitudinally monitor stability changes of implants inserted using traditional rotary instruments or piezoelectric inserts, and to follow their variations during the first 90 days of healing. A randomized, controlled trial was conducted on 20 patients. Each patient received two identical, adjacent implants in the upper premolar area: the test site was prepared with piezosurgery, and the control site was prepared using twist drills. Resonance frequency analysis measurements were taken by a blinded operator on the day of surgery and after 7, 14, 21, 28, 42, 56, and 90 days. At 90 days, 39 out of 40 implants were osseointegrated (one failure in the control group). Both groups showed an initial decrease in mean implant stability quotient (ISQ) values: a shift in implant stability to increasing ISQ values occurred after 14 days in the test group and after 21 days in the control group. The lowest mean ISQ value was recorded at 14 days for test implants (97.3% of the primary stability) and at 21 days for the control implants (90.8% of the primary stability). ISQ variations with respect to primary stability differed significantly between the two groups during the entire period of observation: from day 14 to day 42, in particular, the differences were extremely significant (p < .0001). All 39 implants were in function successfully at the visit scheduled 1 year after insertion. The findings from this study suggest that ultrasonic implant site preparation results in a limited decrease of ISQ values and in an earlier shifting from a decreasing to an increasing stability pattern, when compared with the traditional drilling technique. From a clinical point of view, implants inserted with the piezoelectric technique demonstrated a short-term clinical success similar to those inserted using twist drills. © 2011 Wiley Periodicals, Inc.
An evaluation of the urban stormwater pollutant removal efficiency of catch basin inserts.
Morgan, Robert A; Edwards, Findlay G; Brye, Kristofor R; Burian, Stephen J
2005-01-01
In a storm sewer system, the catch basin is the interface between surface runoff and the sewer. Responding to the need to improve the quality of stormwater from urban areas and transportation facilities, and spurred by Phase I and II Stormwater Rules from the U.S. Environmental Protection Agency, several companies market catch basin inserts as best management practices for urban water quality management. However, little data have been collected under controlled tests that indicate the pollutant removal efficiency of these inserts when the inflow is near what can be expected to occur in the field. A stormwater simulator was constructed to test inserts under controlled and replicable conditions. The inserts were tested for removal efficiency of total suspended solids (TSS) and total petroleum hydrocarbons (TPH) at an inflow rate of 757 to 814 L/min, with influent pollutant concentrations of 225 mg/L TSS and 30 mg/L TPH. These conditions are similar to stormwater runoff from small commercial sites in the southeastern United States. Results from the tests indicate that at the test flowrate and pollutant concentration, average TSS removal efficiencies ranged from 11 to 42% and, for TPH, the removal efficiency ranged from 10 to 19%.
[Forefoot relief with shoe inserts : Effects of different construction strategies].
Baur, H; Merz, N; Muster, A; Flückiger, G; Hirschmüller, A
2018-04-01
Shoe inserts and shoe modifications are used to reduce plantar peak pressure. The effects of different shoe inserts and shoe construction strategies for relief of the forefoot have not yet been sufficiently evaluated. The aim of this study was to analyze the effects of shoe inserts and shoe construction strategies (e.g. metatarsal pad, forefoot cushioning and control) and shoe modifications (e.g. flexible or stiff) on the peak plantar pressure in the forefoot region. In this study 15 healthy subjects were recruited. Plantar pressure distribution was measured using an in-shoe system during walking (3.5km∙h -1 ) on a treadmill and the average plantar peak pressure (kPa) in the forefoot was calculated. The statistics for testing the hypothesis were carried out using 2‑factorial ANOVA with repeat measurements (factors: shoe, insert; α = 0.05). The metatarsal pad and forefoot cushioning led to a reduction of peak pressure, which was statistically significant compared to the control condition (p = 0.009). No differences were observed between both shoe inserts (p > 0.05). A comparison between stiff and flexible shoes revealed a statistically significant pressure reduction in favor of stiff shoes (p = 0.0001). The metatarsal pad led to a peak pressure increase in the midfoot of 12% and by 21% compared to control and forefoot cushioning, respectively. A peak pressure reduction in the forefoot can be achieved with a metatarsal pad or with cushioning; however, the metatarsal pad resulted in a subsequent increase in midfoot pressure. Moreover, shoe construction is crucial because a stiff shoe contributes to a better peak pressure reduction compared to a flexible shoe. Prospective clinical studies should be carried out to prove whether this results in beneficial effects for patients with metatarsalgia.
Controlling band alignments by artificial interface dipoles at perovskite heterointerfaces
Yajima, Takeaki; Hikita, Yasuyuki; Minohara, Makoto; ...
2015-04-07
The concept ‘the interface is the device' is embodied in a wide variety of interfacial electronic phenomena and associated applications in oxide materials, ranging from catalysts and clean energy systems to emerging multifunctional devices. Many device properties are defined by the band alignment, which is often influenced by interface dipoles. On the other hand, the ability to purposefully create and control interface dipoles is a relatively unexplored degree of freedom for perovskite oxides, which should be particularly effective for such ionic materials. Here we demonstrate tuning the band alignment in perovskite metal-semiconductor heterojunctions over a broad range of 1.7 eV.more » This is achieved by the insertion of positive or negative charges at the interface, and the resultant dipole formed by the induced screening charge. This approach can be broadly used in applications where decoupling the band alignment from the constituent work functions and electron affinities can enhance device functionality.« less
Role of nitric oxide in the control of the gastric motility within the nucleus ambiguus of rats.
Sun, H-Z; Zhao, S-Z; Ai, H-B
2012-12-01
This study aims to investigate whether exogenous nitric oxide (NO) plays a role in controlling gastric motility within the nucleus ambiguus (NA). Experiments were performed on male Wistar rats anaesthetized with chloral hydrate. A latex balloon, connected to a pressure transducer, was inserted into the pylorus through the fundus for continuous recording of the change of gastric smooth muscle contractile curves. Microinjection of the NO-donor sodium nitroprusside (SNP; 5 nmol) or L-arginine (L-Arg; 5 nmol) into the NA significantly inhibited gastric motility, whereas the treatment of NO-synthase inhibitor N-nitro-L-arginine methylester (L-NAME) increased gastric motility remarkably. The negative effect of SNP or L-Arg on gastric motility was abolished by bilateral subdiaphragmatic vagotomy as well as by intravenous injection of ganglionic blocker, hexamethonium bromide (Hb). These results demonstrated that NO inhibited gastric motility by activating the cholinergic preganglionic neurons in the NA and through the mediation of vagus nerves.
A technique to control cross-field diffusion of plasma across a transverse magnetic field
NASA Astrophysics Data System (ADS)
Hazarika, P.; Chakraborty, M.; Das, B. K.; Bandyopadhyay, M.
2016-12-01
A study to control charged particle transport across a transverse magnetic field (TMF), popularly known as the magnetic filter in a negative ion source, has been carried out in a double plasma device. In the experimental setup, the TMF placed between the two magnetic cages divides the whole plasma chamber into two distinct regions, viz., the source and the target on the basis of the plasma production and the corresponding electron temperature. The plasma produced in the source region by the filament discharge method diffuses into the target region through the TMF. Data are acquired by the Langmuir probe and are compared in different source configurations, in terms of external biasing applied to metallic plates inserted in the TMF plane but in the orthogonal direction. The effect of the direction of current between the two plates in either polarity of bias in the presence of TMF on the plasma parameters and the cross-field transport of charge particles are discussed.
Seto, Song P; Parks, Akia N; Qiu, Yongzhi; Soslowsky, Louis J; Karas, Spero; Platt, Manu O; Temenoff, Johnna S
2015-09-01
While overuse of the supraspinatus tendon is a leading factor in rotator cuff injury, the underlying biochemical changes have not been fully elucidated. In this study, torn human rotator cuff (supraspinatus) tendon tissue was analyzed for the presence of active cathepsin proteases with multiplex cysteine cathepsin zymography. In addition, an overuse injury to supraspinatus tendons was induced through downhill running in an established rat model. Histological analysis demonstrated that structural damage occurred by 8 weeks of overuse compared to control rats in the region of tendon insertion into bone. In both 4- and 8-week overuse groups, via zymography, there was approximately a 180% increase in cathepsin L activity at the insertion region compared to the controls, while no difference was found in the midsubstance area. Additionally, an over 400% increase in cathepsin K activity was observed for the insertion region of the 4-week overused tendons. More cathepsin K and L immunostaining was observed at the insertion region of the overuse groups compared to controls. These results provide important information on a yet unexplored mechanism for tendon degeneration that may operate alone or in conjunction with other proteases to contribute to chronic tendinopathy.
Seto, Song P.; Parks, Akia N.; Qiu, Yongzhi; Soslowsky, Louis J.; Karas, Spero; Platt, Manu O.; Temenoff, Johnna S.
2015-01-01
While overuse of the supraspinatus tendon is a leading factor in rotator cuff injury, the underlying biochemical changes have not been fully elucidated. In this study, torn human rotator cuff (supraspinatus) tendon tissue was analyzed for the presence of active cathepsin proteases with multiplex cysteine cathepsin zymography. In addition, an overuse injury to supraspinatus tendons was induced through downhill running in an established rat model. Histological analysis demonstrated that structural damage occurred by 8 weeks of overuse compared to control rats in the region of tendon insertion into bone. In both 4- and 8-week overuse groups, via zymography, there was approximately a 180% increase in cathepsin L activity at the insertion region compared to the controls, while no difference was found in the midsubstance area. Additionally, an over 400% increase in cathepsin K activity was observed for the insertion region of the 4-week overused tendons. More cathepsin K and L immunostaining was observed at the insertion region of the overuse groups compared to controls. These results provide important information on a yet unexplored mechanism for tendon degeneration that may operate alone or in conjunction with other proteases to contribute to chronic tendinopathy. PMID:25558848
Li, Dongrui; Cheng, Zhigang; Chen, Gang; Liu, Fangyi; Wu, Wenbo; Yu, Jie; Gu, Ying; Liu, Fengyong; Ren, Chao; Liang, Ping
2018-04-03
To test the accuracy and efficacy of the multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors in phantom and animal models. To evaluate and compare the influences of intervention experience on robot-assisted and ultrasound-controlled ablation procedures. Accuracy tests on rigid body/phantom model with a respiratory movement simulation device and microwave ablation tests on porcine liver tumor/rabbit liver cancer were performed with the robot we designed or with the traditional ultrasound-guidance by physicians with or without intervention experience. In the accuracy tests performed by the physicians without intervention experience, the insertion accuracy and efficiency of robot-assisted group was higher than those of ultrasound-guided group with statistically significant differences. In the microwave ablation tests performed by the physicians without intervention experience, better complete ablation rate was achieved when applying the robot. In the microwave ablation tests performed by the physicians with intervention experience, there was no statistically significant difference of the insertion number and total ablation time between the robot-assisted group and the ultrasound-controlled group. The evaluation by the NASA-TLX suggested that the robot-assisted insertion and microwave ablation process performed by physicians with or without experience were more comfortable. The multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors could increase the insertion accuracy and ablation efficacy, and minimize the influence of the physicians' experience. The ablation procedure could be more comfortable with less stress with the application of the robot.
Putterman, D G; Gryczan, T J; Dubnau, D; Day, L A
1983-01-01
The genome of Pf3, a filamentous single-stranded DNA bacteriophage of Pseudomonas aeruginosa (a gram-negative organism) was cloned into pBD214, a plasmid cloning vector of Bacillus subtilis (a gram-positive organism). Cloning in the gram-positive organism was done to avoid anticipated lethal effects. The entire Pf3 genome was inserted in each orientation at a unique Bc/I site within a thymidylate synthetase gene (from B. subtilis phage beta 22) on the plasmid. Additional clones were made by inserting EcoRI fragments of Pf3 DNA into a unique EcoRI site within this gene. Images PMID:6306273
Methods to Predict Stresses in Cutting Inserts Brazed Using Iron-Carbon Brazing Alloy
NASA Astrophysics Data System (ADS)
Konovodov, V. V.; Valentov, A. V.; Retuynskiy, O. Yu; Esekuev, Sh B.
2016-04-01
This work describes a method for predicting residual and operating stresses in a flat-form tool insert made of tungsten free carbides brazed using iron-carbon alloy. According to the studies’ results it is concluded that the recommendations relating to the limitation of a melting point of tool brazing alloys (950-1100°C according to different data) are connected with a negative impact on tools as a composite made of dissimilar materials rather than on hard alloys as a tool material. Due to the cooling process stresses inevitably occur in the brazed joint of dissimilar materials, and these stresses increase with the higher solidification temperature of the brazing alloy.
Yeo, Caitlin T; Ungi, Tamas; U-Thainual, Paweena; Lasso, Andras; McGraw, Robert C; Fichtinger, Gabor
2011-07-01
The purpose of this study was to determine if augmented reality image overlay and laser guidance systems can assist medical trainees in learning the correct placement of a needle for percutaneous facet joint injection. The Perk Station training suite was used to conduct and record the needle insertion procedures. A total of 40 volunteers were randomized into two groups of 20. 1) The Overlay group received a training session that consisted of four insertions with image and laser guidance, followed by two insertions with laser overlay only. 2) The Control group received a training session of six classical freehand insertions. Both groups then conducted two freehand insertions. The movement of the needle was tracked during the series of insertions. The final insertion procedure was assessed to determine if there was a benefit to the overlay method compared to the freehand insertions. The Overlay group had a better success rate (83.3% versus 68.4%, p=0.002), and potential for less tissue damage as measured by the amount of needle movement inside the phantom (3077.6 mm(2) versus 5607.9 mm(2) , p =0.01). These results suggest that an augmented reality overlay guidance system can assist medical trainees in acquiring technical competence in a percutaneous needle insertion procedure. © 2011 IEEE
Crandell, Douglas W; Mazumder, Shivnath; Evans, P Andrew; Baik, Mu-Hyun
2015-12-01
Density functional theory calculations demonstrate that the reversal of regiochemical outcome of the addition for substituted methyl propiolates in the rhodium-catalyzed [(2 + 2) + 2] carbocyclization with PPh 3 and ( S )-xyl-binap as ligands is both electronically and sterically controlled. For example, the ester functionality polarizes the alkyne π* orbital to favor overlap of the methyl-substituted terminus of the alkyne with the p π -orbital of the alkenyl fragment of the rhodacycle during alkyne insertion with PPh 3 as the ligand. In contrast, the sterically demanding xyl-binap ligand cannot accommodate the analogous alkyne orientation, thereby forcing insertion to occur at the sterically preferred ester terminus, overriding the electronically preferred orientation for alkyne insertion.
The new mid-scala electrode array: a radiologic and histologic study in human temporal bones.
Hassepass, Frederike; Bulla, Stefan; Maier, Wolfgang; Laszig, Roland; Arndt, Susan; Beck, Rainer; Traser, Lousia; Aschendorff, Antje
2014-09-01
To analyze the quality of insertion of the newly developed midscala (MS) electrode, which targets a midscalar electrode position to reduce the risk of trauma to the lateral wall and the modiolus. Modern cochlear implant surgery aims for a safe intracochlear placement of electrode arrays with an ongoing debate regarding cochleostomy or round window (RW) insertion and the use of lateral wall or perimodiolar electrode placement. Intracochlear trauma after insertion of different electrodes depends on insertion mode and electrode design and may result in trauma to the delicate structures of the cochlear. We performed a temporal bone (TB) trial with insertion of the MS electrode in n = 20 TB's after a mastoidectomy and posterior tympanotomy. Insertion was performed either via the RW or a cochleostomy. Electrode positioning, length of insertion, and angle of insertion were analyzed with rotational tomography (RT). TBs were histologically analyzed. Results of RT and histology were compared. Scala tympani (ST) insertion could be accomplished reliably by both RW and via a cochleostomy approach. In 20 TBs, 1 scala vestibuli insertion, 1 incomplete (ST), and 1 elevation of basilar membrane were depicted. No trauma was found in 94.7% of all ST insertions. RT allowed determination of the intracochlear electrode position, which was specified by histologic sectioning. The new MS electrode seems to fulfill reliable atraumatic intracochlear placement via RW and cochleostomy approaches. RT is available for evaluation of intracochlear electrode position, serving as a potential quality control instrument in human implantation.
Spanos, Stephanie; Booth, Rebekah; Koenig, Heidi; Sikes, Kendra; Gracely, Edward; Kim, In K
2008-08-01
Peripheral intravenous (PIV) catheter insertion is a frequent, painful procedure that is often performed with little or no anesthesia. Current approaches that minimize pain for PIV catheter insertion have several limitations: significant delay for onset of anesthesia, inadequate anesthesia, infectious disease exposure risk from needlestick injuries, and patients' needle phobia. Comparison of the anesthetic effectiveness of J-Tip needle-free jet injection of 1% buffered lidocaine to the anesthetic effectiveness of topical 4% ELA-Max for PIV catheter insertion. A prospective, block-randomized, controlled trial comparing J-Tip jet injection of 1% buffered lidocaine to a 30-minute application of 4% ELA-Max for topical anesthesia in children 8 to 15 years old presenting to a tertiary care pediatric emergency department for PIV catheter insertion. All subjects recorded self-reported visual analog scale (VAS) scores for pain at time of enrollment and pain felt following PIV catheter insertion. Jet injection subjects also recorded pain of jet injection. Subjects were videotaped during jet injection and PIV catheter insertion. Videotapes were reviewed by a single blinded reviewer for observer-reported VAS pain scores for jet injection and PIV catheter insertion. Of the 70 children enrolled, 35 were randomized to the J-Tip jet injection group and 35 to the ELA-Max group. Patient-recorded enrollment VAS scores for pain were similar between groups (P = 0.74). Patient-recorded VAS scores were significantly different between groups immediately after PIV catheter insertion (17.3 for J-Tip jet injection vs 44.6 for ELA-Max, P < 0.001). Blinded reviewer assessed VAS scores for pain after PIV catheter insertion demonstrated a similar trend, but the comparison was not statistically significant (21.7 for J-Tip jet injection vs 31.9 ELA-Max, P = 0.23). J-Tip jet injection of 1% buffered lidocaine provided greater anesthesia than a 30-minute application of ELA-Max according to patient self-assessment of pain for children aged 8 to 15 years undergoing PIV catheter insertion.
Cianciulli, Antonia; Calvello, Rosa; Panaro, Maria A
2015-04-01
In the homologous genes studied, the exons and introns alternated in the same order in mouse and human. We studied, in both species: corresponding short segments of introns, whole corresponding introns and complete homologous genes. We considered the total number of nucleotides and the number and orientation of the SINE inserts. Comparisons of mouse and human data series showed that at the level of individual relatively short segments of intronic sequences the stochastic variability prevails in the local structuring, but at higher levels of organization a deterministic component emerges, conserved in mouse and human during the divergent evolution, despite the ample re-editing of the intronic sequences and the fact that processes such as SINE spread had taken place in an independent way in the two species. Intron conservation is negatively correlated with the SINE occupancy, suggesting that virus inserts interfere with the conservation of the sequences inherited from the common ancestor. Copyright © 2015 Elsevier Ltd. All rights reserved.
WITHDRAWN: Grommets (ventilation tubes) for recurrent acute otitis media in children.
Lau, Loretta; Mick, Paul; Nunez, Desmond A
2018-04-06
This is an update of a Cochrane review first published in The Cochrane Library in Issue 4, 2008 and previously updated in 2011.Acute suppurative otitis media is one of the most common infectious diseases in childhood. Recurrent acute otitis media is defined for the purposes of this review as either three or more acute infections of the middle ear cleft in a six-month period, or at least four episodes in a year. Strategies for managing the condition include the assessment and modification of risk factors where possible, repeated courses of antibiotics for each new infection, antibiotic prophylaxis and the insertion of ventilation tubes (grommets). To establish whether grommet insertion reduces the frequency of episodes of recurrent acute otitis media and the proportion of symptomatic children. The Cochrane Ear, Nose and Throat Disorders Group (CENTDG) Trials Search Co-ordinator searched the CENTDG Trials Register; Central Register of Controlled Trials (CENTRAL 2014, Issue 10); PubMed; EMBASE; CINAHL; Web of Science; Clinicaltrials.gov; ICTRP and additional sources for published and unpublished trials. The date of the search was 6 November 2014. Randomised controlled trials comparing grommet insertion versus control (antibiotics/other treatments/no treatment) for recurrent acute otitis media in children aged from 0 to 16 years. Two authors independently selected studies. Three authors independently assessed study quality and extracted data. We synthesised data descriptively. Two randomised controlled trials with a total of 148 participants are included in this review. The overall risk of bias in the studies is unclear.The first study randomised 95 children to grommets or control (antibiotic treatment of acute otitis media episodes). For the primary outcome, this study showed that grommet insertion leads to a mean reduction of 1.5 episodes of acute otitis media in the first six months after treatment. In six months of follow-up significantly more children in the grommet group had no episodes of acute otitis media (P value < 0.001). Complications of surgery included grommet blockage with acute otitis media requiring re-operation within six months in 3/54 children who underwent grommet insertion. Adverse effects were not documented in the control group. The following pre-defined secondary outcomes were not reported: change in symptom scores for otalgia or otorrhoea, alteration in the frequency of otalgia or otorrhoea, and number of days at nursery or school lost secondary to acute otitis media.The second study reported on 53 of 68 children who were randomised to grommet insertion or six months of once a day sulfamethoxazole and trimethoprim antibiotic prophylaxis. There was no significant difference in the primary outcome, number of episodes of acute otitis media, during the six-month follow-up between grommet insertion and antibiotic treatment groups (64.5% in the surgical group versus 45.4% in the antibiotic group had no recurrence, P value = 0.4). Two participants underwent grommet re-insertion to replace extruded tubes during the follow-up period. The only other adverse effect reported was the development of a skin rash in two patients in the medical group. Other pre-defined secondary outcome measures were not reported. The study has a high risk of bias and the results should be interpreted cautiously. Grommets significantly increase the number of acute otitis media-free children in the first six months after insertion compared to children who receive no treatment. Grommet insertion maybe of equivalent efficacy to once a day antibiotic prophylaxis. Further research is required to confirm the advantage of grommets over no treatment, investigate the effect beyond six months, compare grommet effectiveness against alternative active treatments and confirm the low risk of adverse effects compared to no treatment and all active treatments in recurrent acute otitis media. In the interim clinicians should consider the possible adverse effects of grommet insertion and alternative treatments before recommending surgery.
Combinatorial events of insertion sequences and ICE in Gram-negative bacteria.
Toleman, Mark A; Walsh, Timothy R
2011-09-01
The emergence of antibiotic and antimicrobial resistance in Gram-negative bacteria is incremental and linked to genetic elements that function in a so-called 'one-ended transposition' manner, including ISEcp1, ISCR elements and Tn3-like transposons. The power of these elements lies in their inability to consistently recognize one of their own terminal sequences, while recognizing more genetically distant surrogate sequences. This has the effect of mobilizing the DNA sequence found adjacent to their initial location. In general, resistance in Gram-negatives is closely linked to a few one-off events. These include the capture of the class 1 integron by a Tn5090-like transposon; the formation of the 3' conserved segment (3'-CS); and the fusion of the ISCR1 element to the 3'-CS. The structures formed by these rare events have been massively amplified and disseminated in Gram-negative bacteria, but hitherto, are rarely found in Gram-positives. Such events dominate current resistance gene acquisition and are instrumental in the construction of large resistance gene islands on chromosomes and plasmids. Similar combinatorial events appear to have occurred between conjugative plasmids and phages constructing hybrid elements called integrative and conjugative elements or conjugative transposons. These elements are beginning to be closely linked to some of the more powerful resistance mechanisms such as the extended spectrum β-lactamases, metallo- and AmpC type β-lactamases. Antibiotic resistance in Gram-negative bacteria is dominated by unusual combinatorial mistakes of Insertion sequences and gene fusions which have been selected and amplified by antibiotic pressure enabling the formation of extended resistance islands. © 2011 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.
Tavakolian, Samira; Doulabi, Mahbobeh Ahmadi; Baghban, Alireza Akbarzade; Mortazavi, Alireza; Ghorbani, Maryam
2015-01-01
Introduction: Copper IUD is a long term and reversible contraception which equals tubal ligation in terms of sterilization. One of the barriers to using this contraception method is the fear and the pain associated with its insertion. Eutectic mixture of local anesthetics (EMLA) 5% is a local anesthetic that contains 25 mg lidocaine and 25 mg of prilocaine per gram. Application of topical analgesic cream to the cervix for laser surgery, hysteroscopy and hysterosalpingography is known Aims: this study aimed to determine the effect of EMLA on IUD insertion pain. Methods: This triple blind clinical trial was conducted on 92 women in a clinic in Hamedan in 2012. After applying the cream on the cervix, pain in three steps, after using Tenaculum, after inserting hystrometr and after inserting IUD and removing IUD insertion tube were assessed with visual analog scale and were compared in EMLA group and placebo group Statistical analysis used to determine and compare the pain of independent t tests, Mann-Whitney U test and repeated measures analysis of variance and chi-square tests to determine the homogeneity of variables and Fisher’s exact test was used Results: Insertion hystrometr was determined as the most painful IUD insertion. The mean pain at step 2 (inserting hystrometr) was (3/11±2/53) in EMLA group, (5/23±2/31) in placebo group. EMLA cream significantly reduced the pain after using tenaculum (P<0/001), pain inserting Hystrometr (P< 0/001) and pain at IUD insertion and removing insertion tube (P< 0/001) Conclusions: Topical Application of EMLA 5% cream as a topical anesthetic on the cervix before insertion IUD reduced the pain during this procedure. PMID:25946948
Basal forebrain infusion of HC-3 in rats: maze learning deficits and neuropathology.
Hurlbut, B J; Lubar, J F; Switzer, R; Dougherty, J; Eisenstadt, M L
1987-01-01
Ten adult male Sprague-Dawley rats were infused with hemicholinium (HC-3) using mini-osmotic pumps over a 14 day period through bilateral, chronically implanted cannulae in the nucleus basalis magnocellularis (nbm). Ten matched controls were infused in the same fashion with saline. HC-3 rats receiving implants demonstrated a significant deficit in maze-learning ability compared with individual and group performances before receiving the implants. In saline rats there was no significant difference in maze-learning ability before and after receiving implants. The HC-3 group receiving implants demonstrated a significant deficit in maze-learning ability compared with the saline control group. Serial sections through nbm from control and HC-3 rats indicated that all cannulae were located within infusion range of nbm. In HC-3 subjects, cholinergic cell bodies were destroyed with concurrent degeneration of terminal fields in cortex. Except for cannula insertion damage, the cholinergic neurotransmitter system appeared unharmed in controls. Stains for neuritic plaques and neurofibrillary damage were negative in both groups. The memory deficit in experimental subjects supported by the demonstrated destruction of nbm cholinergic neurons suggests that HC-3 may be useful in the development of an animal model for Alzheimer's Disease.
Dominant-Negative Mutants of a Toxin Subunit: An Approach to Therapy of Anthrax
NASA Astrophysics Data System (ADS)
Sellman, Bret R.; Mourez, Michael; John Collier, R.
2001-04-01
The protective antigen moiety of anthrax toxin translocates the toxin's enzymic moieties to the cytosol of mammalian cells by a mechanism that depends on its ability to heptamerize and insert into membranes. We identified dominant-negative mutants of protective antigen that co-assemble with the wild-type protein and block its ability to translocate the enzymic moieties across membranes. These mutants strongly inhibited toxin action in cell culture and in an animal intoxication model, suggesting that they could be useful in therapy of anthrax.
Chang, Mun Young; Gwon, Tae Mok; Lee, Ho Sun; Lee, Jun Ho; Oh, Seung Ha; Kim, Sung June; Park, Min-Hyun
2017-03-15
The present study aimed to evaluate the effects of systemic lipoic acid on hearing preservation after cochlear implantation. Twelve Dunkin-Hartley guinea pigs were randomly divided into two groups: the control group and the lipoic acid group. Animals in the lipoic acid group received lipoic acid intraperitoneally for 4 weeks. A sterilised silicone electrode-dummy was inserted through the round window to a depth of approximately 5 mm. The hearing level was measured using auditory brainstem responses (ABRs) prior to electrode-dummy insertion, and at 4 days and 1, 2, 3 and 4 weeks after electrode-dummy insertion. The threshold shift was defined as the difference between the pre-operative threshold and each of the post-operative thresholds. The cochleae were examined histologically 4 weeks after electrode-dummy insertion. Threshold shifts changed with frequency but not time. At 2kHz, ABR threshold shifts were statistically significantly lower in the lipoic acid group than the control group. At 8, 16 and 32kHz, there was no significant difference in the ABR threshold shift between the two groups. Histologic review revealed less intracochlear fibrosis along the electrode-dummy insertion site in the lipoic acid group than in the control group. The spiral ganglion cell densities of the basal, middle and apical turns were significantly higher in the lipoic acid group compared with the control group. Therefore, systemic lipoic acid administration appears to effectively preserve hearing at low frequencies in patients undergoing cochlear implantation. These effects may be attributed to the protection of spiral ganglion cells and prevention of intracochlear fibrosis. Copyright © 2017 Elsevier B.V. All rights reserved.
Sodium titanate nanotubes as negative electrode materials for sodium-ion capacitors.
Yin, Jiao; Qi, Li; Wang, Hongyu
2012-05-01
The lithium-based energy storage technology is currently being considered for electric automotive industry and even electric grid storage. However, the hungry demand for vast energy sources in the modern society will conflict with the shortage of lithium resources on the earth. The first alternative choice may be sodium-related materials. Herein, we propose an electric energy storage system (sodium-ion capacitor) based on porous carbon and sodium titanate nanotubes (Na-TNT, Na(+)-insertion compounds) as positive and negative electrode materials, respectively, in conjunction with Na(+)-containing non-aqueous electrolytes. As a low-voltage (0.1-2 V) sodium insertion nanomaterial, Na-TNT was synthesized via a simple hydrothermal reaction. Compared with bulk sodium titanate, the predominance of Na-TNT is the excellent rate performance, which exactly caters to the need for electrochemical capacitors. The sodium-ion capacitors exhibited desirable energy density and power density (34 Wh kg(-1), 889 W kg(-1)). Furthermore, the sodium-ion capacitors had long cycling life (1000 cycles) and high coulombic efficiency (≈ 98 % after the second cycle). More importantly, the conception of sodium-ion capacitor has been put forward.
Insight into the split and asymmetry of charge distribution in biased M-structure superlattice
NASA Astrophysics Data System (ADS)
Liu, Lu; Bi, Han; Zhao, Yunhao; Zhao, Xuebing; Han, Xi; Wang, Guowei; Xu, Yingqiang; Li, Yuesheng; Che, Renchao
2017-07-01
The charge distribution in real space of an insertion variant based on an InAs/GaSb superlattice for an infrared detector is illustrated by in situ electron microscopy. The localization split of positive charge can be directly observed in the InAs/GaSb/AlSb/GaSb superlattice (M-structure) rather than in the InAs/GaSb superlattice. With the applied bias increasing from 0 to 4.5 V, the double peaks of positive charge density become asymmetrical gradually, with the peak integral ratio ranging from 1.13 to 2.54. Simultaneously, the negative charges move along the direction of the negative electric field. Without inserting the AlSb layer, the charge inversion occurs in both the hole wells and the electron wells of the InAs/GaSb superlattice under high bias. Such a discrepancy between the M-structure superlattice and the traditional superlattice suggests an effective reduction of tunneling probability of the M-structure design. Our result is of great help to understand the carrier immigration mechanism of the superlattice-based infrared detector.
Okumura, M; Toriizuka, K; Iijima, K; Haruyama, K; Ishino, S; Cyong, J C
1999-01-01
The aim of this study was to investigate the effects of acupuncture on peripheral lymphocyte subpopulations and cerebral catecholamines. In order to examine the effects of acupuncture, two experiments were performed. Experiment 1: Eighteen female mice (strain; C57BL/6) at the age of 7 weeks were divided three groups, (a) sham operated (control; n=6), (b) ovariectomized (OVX; n=6), and (c) ovariectomized and stimulated by subcutaneous needles on acupuncture point, Shenshu (BL23) at the both sides of the back for 20 days (OVX+Acu; n=6). These animals were sacrificed at 20 days after needle insertion, and the splenic lymphoid cells were examined by two-color flow cytometry, using monoclonal antibodies (mAb) to the cell surface antigens, CD3, CD4, CD8a and NK1.1 (CD56). In the ovariectomized (OVX) group, the peripheral CD4/CD8 ratio was significantly increased and the ratio of natural killer (NK) cells (CD3-NK1.1+; CD3 negative, NK1.1 positive) to T lymphocytes was decreased compared to the sham control group. In the ovariectomized with needle insertion (OVX+Acu) group, the CD4/CD8 ratio was reduced, but the NK cells ratio was not changed compared to the OVX group. Experiment 2: To investigate the acute effects of subcutaneous needle insertion, male C57BL/6 mice (7 weeks old) were used (n=6, each group). The acupuncture points Shen-shu (BL23) on the backs of the male mice were also stimulated by subcutaneous needles for 3 and 7 days. As a result, the CD4/CD8 ratio was significantly decreased at day 3 and day 7, compared to the control group. On the other hand the NK cells ratio and activated T-cells were increased at day 7. The mitogenic activities in the splenic lymphocytes were also increased by acupuncture stimulation at day 3. Catecholamine contents in the hippocampus were measured by high performance liquid chromatography with the electro-chemical detector (ECD-HPLC) method. No significant change was observed in either dopamine contents or norepinephrine; however, dopamine metabolite, homovanillic acid (HVA) and DOPAC (3,4-dihydroxyphenylacetic acid) were increased at day 3. The study suggests that acupuncture has effects on peripheral lymphocyte subpopulations and may modulate mitogenic activity. In addition, acupuncture may stimulate dopamine turnover.
Chen, San-Ni; Hsieh, Yi-Ting; Yang, Chung-May
2018-06-06
The aim of this paper was to evaluate the efficacy of multiple free internal limiting membrane (ILM) flap insertion in the management of macular hole-associated retinal detachment in high myopia. Eyes receiving operation for macular hole-associated retinal detachment were retrospectively recruited. Those in the study group received ILM peeling and multiple free ILM flap insertion, while those in the control group received ILM peeling only. Postoperative anatomical outcomes and best-corrected visual acuity were compared between the 2 groups. Twenty-seven eyes of 27 patients were recruited in this study (13 in the study group, 14 in the control group). After the operation, the retina was reattached in all cases in both groups. The macular hole closure rate was 100% in the study group but only 42.9% in the control group (adjusted p < 0.001). The eyes in the study group had better visual improvement (logMAR -0.58 ± 0.43) than those in the control group (logMAR -0.31 ± 0.50) with borderline significance (adjusted p = 0.078). For macular hole-associated retinal detachment in highly myopic eyes, the multiple free ILM flap insertion technique offers an effective way to close macular holes. Whether this result also means better visual outcome remains to be seen. © 2018 S. Karger AG, Basel.
First results from negative ion beam extraction in ROBIN in surface mode
NASA Astrophysics Data System (ADS)
Pandya, Kaushal; Gahlaut, Agrajit; Yadav, Ratnakar K.; Bhuyan, Manas; Bandyopadhyay, Mainak; Das, B. K.; Bharathi, P.; Vupugalla, Mahesh; Parmar, K. G.; Tyagi, Himanshu; Patel, Kartik; Bhagora, Jignesh; Mistri, Hiren; Prajapati, Bhavesh; Pandey, Ravi; Chakraborty, Arun. K.
2017-08-01
ROBIN, the first step in the Indian R&D program on negative ion beams has reached an important milestone, with the production of negative ions in the surface conversion mode through Cesium (Cs) vapor injection into the source. In the present set-up, negative hydrogen ion beam extraction is effected through an extraction area of ˜73.38 cm2 (146 apertures of 8mm diameter). The three grid electrostatic accelerator system of ROBIN is fed by high voltage DC power supplies (Extraction Power Supply System: 11kV, 35A and Acceleration Power Supply System: 35kV, 15A). Though, a considerable reduction of co-extracted electron current is usually observed during surface mode operation, in order to increase the negative ion current, various other parameters such as plasma grid temperature, plasma grid bias, extraction to acceleration voltage ratio, impurity control and Cs recycling need to be optimized. In the present experiments, to control and to understand the impurity behavior, a Cryopump (14,000 l/s for Hydrogen) is installed along with a Residual Gas Analyzer (RGA). To characterize the source plasma, two sets of Langmuir probes are inserted through the diagnostic flange ports available at the extraction plane. To characterize the beam properties, thermal differential calorimeter, Doppler Shift Spectroscopy and electrical current measurements are implemented in ROBIN. In the present set up, all the negative ion beam extraction experiments have been performed by varying different experimental parameters e.g. RF power (30-70 kW), source operational pressure (0.3 - 0.6Pa), plasma grid bias voltage, extraction & acceleration voltage combination etc. The experiments in surface mode operation is resulted a reduction of co-extracted electron current having electron to ion ratio (e/i) ˜2 whereas the extracted negative ion current density was increased. However, further increase in negative ion current density is expected to be improved after a systematic optimization of the operational parameters and Cs conditioning of the source. It was also found out that a better performance of ROBIN is achieved in the pressure range: 0.5-0.6 Pa. In this paper, the preliminary results on parametric study of ROBIN operation and beam optimization in surface mode are discussed.
Herbenick, Debby; Hensel, Devon; Smith, Nicole K; Schick, Vanessa; Reece, Michael; Sanders, Stephanie A; Fortenberry, J Dennis
2013-03-01
Pubic hair removal is prevalent among women in the United States. However, most studies related to pubic hair removal are based on cross-sectional surveys and retrospective recall. The purpose of this research was to, in a prospective event-level daily diary study, assess demographic, affective, relational, situational, and behavioral factors related to women's pubic hair removal. Data collection occurred as part of a 5-week prospective, Internet-based daily diary study. Age; Affective predictors (positive mood, negative mood, feeling interested in sex, feeling in love); Relational predictors (partner support, partner negativity, partner type, partner gender); Situational predictors (any vaginal symptoms, use of any vaginal hygiene products; having applied any creams to the genitals); Behavioral variables (penile-vaginal sex, penile-anal sex, had finger inserted into vagina, had clitoris stimulated with fingers, inserted toy into vagina, used vibrator on clitoris, inserted finger into anus, inserted toy into anus, duration of penetration, intensity of penetration). A total of 2,453 women ages 18 to 68 (mean age 32.69) completed the study, contributing 49,287 total diaries (mean per person 24.5; standard deviation 10.3, median 30); 15.2% of all days (N = 7,362) involved pubic hair waxing or shaving, with the vast majority of hair removal days involving shaving (N = 7,302; 99%). Pubic hair removal was significantly associated with younger age, a greater interest in sex, vaginal fingering, finger-clitoral stimulation, having a casual sex partner, using vaginal hygiene products, and applying cream to the genitals. Hair removal was marginally associated with longer duration of vaginal penetration. These findings provide greater insight into the factors associated with women's pubic hair removal and their sexual experiences on a day-to-day level. Clinical and educational implications are discussed. © 2012 International Society for Sexual Medicine.
Pallaver, Carl B.; Morgan, Michael W.
1978-01-01
A cryogenic expansion engine includes intake and exhaust poppet valves each controlled by a cam having adjustable dwell, the valve seats for the valves being threaded inserts in the valve block. Each cam includes a cam base and a ring-shaped cam insert disposed at an exterior corner of the cam base, the cam base and cam insert being generally circular but including an enlarged cam dwell, the circumferential configuration of the cam base and cam dwell being identical, the cam insert being rotatable with respect to the cam base. GI CONTRACTUAL ORIGIN OF THE INVENTION The invention described herein was made in the course of, or under, a contract with the UNITED STATES ENERGY RESEARCH AND DEVELOPMENT ADMINISTRATION.
New Transposon Tools Tailored for Metabolic Engineering of Gram-Negative Microbial Cell Factories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martínez-García, Esteban; Aparicio, Tomás; Lorenzo, Víctor de
Re-programming microorganisms to modify their existing functions and/or to bestow bacteria with entirely new-to-Nature tasks have largely relied so far on specialized molecular biology tools. Such endeavors are not only relevant in the burgeoning metabolic engineering arena but also instrumental to explore the functioning of complex regulatory networks from a fundamental point of view. À la carte modification of bacterial genomes thus calls for novel tools to make genetic manipulations easier. We propose the use of a series of new broad-host-range mini-Tn5-vectors, termed pBAMDs, for the delivery of gene(s) into the chromosome of Gram-negative bacteria and for generating saturated mutagenesismore » libraries in gene function studies. These delivery vectors endow the user with the possibility of easy cloning and subsequent insertion of functional cargoes with three different antibiotic-resistance markers (kanamycin, streptomycin, and gentamicin). After validating the pBAMD vectors in the environmental bacterium Pseudomonas putida KT2440, their use was also illustrated by inserting the entire poly(3-hydroxybutyrate) (PHB) synthesis pathway from Cupriavidus necator in the chromosome of a phosphotransacetylase mutant of Escherichia coli. PHB is a completely biodegradable polyester with a number of industrial applications that make it attractive as a potential replacement of oil-based plastics. The non-selective nature of chromosomal insertions of the biosynthetic genes was evidenced by a large landscape of PHB synthesis levels in independent clones. One clone was selected and further characterized as a microbial cell factory for PHB accumulation, and it achieved polymer accumulation levels comparable to those of a plasmid-bearing recombinant. Taken together, our results demonstrate that the new mini-Tn5-vectors can be used to confer interesting phenotypes in Gram-negative bacteria that would be very difficult to engineer through direct manipulation of the structural genes.« less
The New Chemicals Exposure Limits (NCELs) section 5(e) Consent Order insert presents the standard NCELs provisions. The actual NCEL concentration is an empty blank to be completed depending on the toxicity of the specific chemical involved.
Cornelis, P; Anjaiah, V; Koedam, N; Delfosse, P; Jacques, P; Thonart, P; Neirinckx, L
1992-07-01
Tn5 mutagenesis of different fluorescent pseudomonads was achieved by conjugational transfer of the suicide vector pSUP 10141. Pyoverdine negative (Pvd-) mutants were detected by the absence of fluorescence on King's B medium and by their inability to grow in the presence of the iron chelator EDDHA [ethylenediamine di(o-hydroxyphenylacetic acid)]. In P. fluorescens ATCC 17400 and three rhizosphere isolates (one P. putida and two P. fluorescens), the percentage of Pvd- mutants ranged between 0 and 0.54%. In a P. chlororaphis rhizosphere isolate, this percentage was higher (4%). In these mutants both of the Tn5 antibiotic resistances (Km and Tc) were stable and the transposon could be detected by hybridization. In Pvd- mutants of P. fluorescens ATCC 17400, the transposon was found to be inserted twice in the chromosome while single insertions were detected in the DNA of other, randomly tested mutants. In P. aeruginosa PAO1, where 13.1% of the mutants were Pvd-, both antibiotic resistances were rapidly lost and accordingly no transposon insertion could be detected by hybridization. However, the Pvd- phenotype was generally stable in these mutants. The plasmid pNK862 containing a mini-Tn10 transposon was introduced by electroporation into P. aeruginosa PAO1 and Kmr mutants were recovered, 89% of which were Pvd- and confirmed to be P. aeruginosa by PCR amplification of the P. aeruginosa lipoprotein gene. The mini-Tn10 insertions were also found to be unstable in PAO1.
Shariati, A; Azimi, T; Ardebili, A; Chirani, A S; Bahramian, A; Pormohammad, A; Sadredinamin, M; Erfanimanesh, S; Bostanghadiri, N; Shams, S; Hashemi, A
2018-01-01
In this study, we report the insertion sequence IS Ppu 21 in the opr D porin gene of carbapenem-resistant Pseudomonas aeruginosa isolates from burn patients in Tehran, Iran. Antibiotic susceptibility tests for P. aeruginosa isolates were determined. Production of metallo-β-lactamases (MBLs) and carbapenemase was evaluated and the β-lactamase-encoding and aminoglycoside-modifying enzyme genes were investigated by PCR and sequencing methods. The mRNA transcription level of oprD and mex efflux pump genes were evaluated by real-time PCR. The outer membrane protein profile was determined by SDS-PAGE. The genetic relationship between the P. aeruginosa isolates was assessed by random amplified polymorphic DNA PCR. In all, 10.52% (10/95) of clinical isolates of P. aeruginosa harboured the IS Ppu 21 insertion element in the opr D gene. The extended-spectrum β-lactamase-encoding gene in IS Ppu 21-carrying isolates was bla TEM . PCR assays targeting MBL and carbapenemase-encoding genes were also negative in all ten isolates. The rmt A, aad A, aad B and arm A genes were positive in all IS Ppu 21 harbouring isolates. The relative expression levels of the mex X, mex B, mex T and mex D genes in ten isolates ranged from 0.1- to 1.4-fold, 1.1- to 3.68-fold, 0.3- to 8.22-fold and 1.7- to 35.17-fold, respectively. The relative expression levels of the oprD in ten isolates ranged from 0.57- to 35.01-fold, which was much higher than those in the control strain P. aeruginosa PAO1. Evaluation of the outer membrane protein by SDS-PAGE suggested that opr D was produced at very low levels by all isolates. Using random amplified polymorphic DNA PCR genotyping, eight of the ten isolates containing IS Ppu 21 were shown to be clonally related. The present study describes a novel molecular mechanism, IS Ppu 21 insertion of the opr D gene, associated with carbapenem resistance in clinical P. aeruginosa isolates.
A new spiral dental implant: a tool for oral rehabilitation of difficult cases
BALAN, I.; CALCATERRA, R.; LAURITANO, D.; GRECCHI, E.; CARINCI, F.
2017-01-01
SUMMARY Spiral dental implant (SDI) is an implant with a conical internal helix that confers the characteristic of self-drilling, self-tapping, and self-bone condensing. These proprieties offer better control during insertion of SDI giving a high primary stabilization, even in poor quality bone. A shorter diameter of SDI results in reduced drilling during insertion and consequently less trauma and minimal bone loss. To address the research purpose, the investigators designed a retrospective cohort study. The study population was composed of 25 patients, 11 males and 14 females that have been treated by Dr. Balan with 187 SDI positioned in mandible and into maxilla bone. The implants were placed during the years 2013 to 2014 in Dr. Balan clinic. All patients underwent the same surgical protocol. Several variables are investigated: demographic (age and gender), anatomic (upper/lower jaws and tooth site), implant (length and diameter and type) variables, edentulism (partial or total), and comorbid status of health (i.e.: hypothyroidism, parodontitis, hypertension, diabetes, presence of cancer, heart disease, hepatitis and rheumatologic disease). Pearson Chi-Square test was used to investigate variables and p < 0.05 was considered statistically significant. Statistically it has been shown that females have a higher possibility of unsuccessful respect of male, with a “p value” of 0.014. Another important impact factor for success of implant insertion has been represented by concomitants pathologies: cancer represents the most negative high factor risk with a percentage of unsuccessful of 50%, followed by heart disease (15%), and diabetes (3.7%). SDIs are reliable tools for difficult cases of oral rehabilitation. They have a higher success and survival rate, which means stable results over time. No differences were detected among SDI lengths, implant/crown ratio. In addition, the insertion of SDIs in banked bone can be performed without adverse effects. Finally, flapless and computer tomography-planned surgery does not significantly increase the clinical outcome of SDIs in complex rehabilitation. Cancer represents the most important variable to consider when a patient wants to do oral rehabilitation because of its high risk of unsuccessful. PMID:29285328
A new spiral dental implant: a tool for oral rehabilitation of difficult cases.
Balan, I; Calcaterra, R; Lauritano, D; Grecchi, E; Carinci, F
2017-01-01
Spiral dental implant (SDI) is an implant with a conical internal helix that confers the characteristic of self-drilling, self-tapping, and self-bone condensing. These proprieties offer better control during insertion of SDI giving a high primary stabilization, even in poor quality bone. A shorter diameter of SDI results in reduced drilling during insertion and consequently less trauma and minimal bone loss. To address the research purpose, the investigators designed a retrospective cohort study. The study population was composed of 25 patients, 11 males and 14 females that have been treated by Dr. Balan with 187 SDI positioned in mandible and into maxilla bone. The implants were placed during the years 2013 to 2014 in Dr. Balan clinic. All patients underwent the same surgical protocol. Several variables are investigated: demographic (age and gender), anatomic (upper/lower jaws and tooth site), implant (length and diameter and type) variables, edentulism (partial or total), and comorbid status of health (i.e.: hypothyroidism, parodontitis, hypertension, diabetes, presence of cancer, heart disease, hepatitis and rheumatologic disease). Pearson Chi-Square test was used to investigate variables and p < 0.05 was considered statistically significant. Statistically it has been shown that females have a higher possibility of unsuccessful respect of male, with a "p value" of 0.014. Another important impact factor for success of implant insertion has been represented by concomitants pathologies: cancer represents the most negative high factor risk with a percentage of unsuccessful of 50%, followed by heart disease (15%), and diabetes (3.7%). SDIs are reliable tools for difficult cases of oral rehabilitation. They have a higher success and survival rate, which means stable results over time. No differences were detected among SDI lengths, implant/crown ratio. In addition, the insertion of SDIs in banked bone can be performed without adverse effects. Finally, flapless and computer tomography-planned surgery does not significantly increase the clinical outcome of SDIs in complex rehabilitation. Cancer represents the most important variable to consider when a patient wants to do oral rehabilitation because of its high risk of unsuccessful.
Ribeiro, Giselle R; Campos, Camila H; Rodrigues Garcia, Renata Cunha Matheus
2017-11-01
Parkinson disease (PD) symptoms, such as muscle rigidity, tremors in the lips and tongue, and involuntary mandibular movements, may cause oral health-related problems, mastication difficulties, and denture discomfort because of the difficulty in controlling a prosthesis with the oral musculature. The purpose of this observational clinical study was to evaluate the influence of oral rehabilitation with a removable prosthesis on oral health-related quality of life (OHRQoL) and masticatory efficiency (ME) in elders with PD. Thirty-four elders with PD (n=17, mean age 69.4 ±4.7 years) or without PD (n=17, mean age 70.7 ±4.7 years) were recruited. All participants first underwent OHRQoL and ME evaluations. Two months after the insertion of new removable prostheses, the participants were reassessed. The OHRQoL was measured with the Oral Health Impact Profile (OHIP-49). ME was evaluated by determining the percentage weight of the comminuted silicone-based artificial material that passed through a 2.8 mm sieve. For each group, data were compared between baseline and after insertion of new removable prostheses by paired t test or Wilcoxon sign test/signed-rank test. Group differences were assessed at each time point by t test (α=.05). After the insertion of removable prostheses, elders with PD showed improved OHRQoL and ME. Controls also showed improvements on both measures after insertion of removable prostheses. At baseline, elders with PD had lower OHRQoL and ME compared with the controls (P<.05). After removable prosthesis insertion, the elders with PD continued to show lower ME values than the controls, but their OHRQoL was similar. Oral rehabilitation with new removable dental prostheses improved the OHRQoL and ME in elders with and without PD, although ME did not reach control levels in elders with PD. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Endpoint Accuracy in Manual Control of a Steerable Needle.
van de Berg, Nick J; Dankelman, Jenny; van den Dobbelsteen, John J
2017-02-01
To study the ability of a human operator to manually correct for errors in the needle insertion path without partial withdrawal of the needle by means of an active, tip-articulated steerable needle. The needle is composed of a 1.32-mm outer-diameter cannula, with a flexure joint near the tip, and a retractable stylet. The bending stiffness of the needle resembles that of a 20-gauge hypodermic needle. The needle functionality was evaluated in manual insertions by steering to predefined targets and a lateral displacement of 20 mm from the straight insertion line. Steering tasks were conducted in 5 directions and 2 tissue simulants under image guidance from a camera. The repeatability in instrument actuations was assessed during 100 mm deep automated insertions with a linear motor. In addition to tip position, tip angles were tracked during the insertions. The targeting error (mean absolute error ± standard deviation) during manual steering to 5 different targets in stiff tissue was 0.5 mm ± 1.1. This variability in manual tip placement (1.1 mm) was less than the variability among automated insertions (1.4 mm) in the same tissue type. An increased tissue stiffness resulted in an increased lateral tip displacement. The tip angle was directly controlled by the user interface, and remained unaffected by the tissue stiffness. This study demonstrates the ability to manually steer needles to predefined target locations under image guidance. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
A Predictive Model of Intein Insertion Site for Use in the Engineering of Molecular Switches
Apgar, James; Ross, Mary; Zuo, Xiao; Dohle, Sarah; Sturtevant, Derek; Shen, Binzhang; de la Vega, Humberto; Lessard, Philip; Lazar, Gabor; Raab, R. Michael
2012-01-01
Inteins are intervening protein domains with self-splicing ability that can be used as molecular switches to control activity of their host protein. Successfully engineering an intein into a host protein requires identifying an insertion site that permits intein insertion and splicing while allowing for proper folding of the mature protein post-splicing. By analyzing sequence and structure based properties of native intein insertion sites we have identified four features that showed significant correlation with the location of the intein insertion sites, and therefore may be useful in predicting insertion sites in other proteins that provide native-like intein function. Three of these properties, the distance to the active site and dimer interface site, the SVM score of the splice site cassette, and the sequence conservation of the site showed statistically significant correlation and strong predictive power, with area under the curve (AUC) values of 0.79, 0.76, and 0.73 respectively, while the distance to secondary structure/loop junction showed significance but with less predictive power (AUC of 0.54). In a case study of 20 insertion sites in the XynB xylanase, two features of native insertion sites showed correlation with the splice sites and demonstrated predictive value in selecting non-native splice sites. Structural modeling of intein insertions at two sites highlighted the role that the insertion site location could play on the ability of the intein to modulate activity of the host protein. These findings can be used to enrich the selection of insertion sites capable of supporting intein splicing and hosting an intein switch. PMID:22649521
Ioannou, Christopher; Knight, Matthew; Daniele, Luca; Flueckiger, Lee; Tan, Ezekiel S L
2016-10-17
The objective of this study is to analyse the effectiveness of the surgical torque limiter during operative use. The study also investigates the potential differences in torque between hand and drill-based screw insertion into locking plates using a standardised torque limiter. Torque for both hand and power screw insertion was measured through a load cell, registering 6.66 points per second. This was performed in a controlled environment using synthetic bone, a locking plate and locking screws to simulate plate fixation. Screws were inserted by hand and by drill with torque values measured. The surgical torque limiter (1.5 Nm) was effective as the highest recorded reading in the study was 1.409 Nm. Comparatively, there is a statistically significant difference between screw insertion methods. Torque produced for manually driven screw insertion into locking plates was 1.289 Nm (95 % CI 1.269-1.308) with drill-powered screw insertion at 0.740 Nm (95 % CI 0.723-0.757). The surgical torque limiter proved to be effective as per product specifications. Screws inserted under power produce significantly less torque when compared to manual insertion by hand. This is likely related to the mechanism of the torque limiter when being used at higher speeds for which it was designed. We conclude that screws may be inserted using power to the plate with the addition of a torque limiter. It is recommended that all screws inserted by drill be hand tightened to achieve adequate torque values.
Nguyen, Yann; Bernardeschi, Daniele; Kazmitcheff, Guillaume; Miroir, Mathieu; Vauchel, Thomas; Ferrary, Evelyne; Sterkers, Olivier
2015-02-01
Loading otoprotective drug into cochlear implant might change its mechanical properties, thus compromising atraumatic insertion. This study evaluated the effect of incorporation of dexamethasone (DXM) in the silicone of cochlear implant arrays on insertion forces. Local administration of DXM with embedded array can potentially reduce inflammation and fibrosis after cochlear implantation procedure to improve hearing preservation and reduce long-term impedances. Four models of arrays have been tested: 0.5-mm distal diameter array (n = 5) used as a control, drug-free 0.4-mm distal diameter array (n = 5), 0.4-mm distal diameter array with 1% eluded DXM silicone (n = 5), and 0.4-mm distal diameter array with 10% eluded DXM silicone (n = 5). Via a motorized insertion bench, each array has been inserted into an artificial scala tympani model. The forces were recorded by a 6-axis force sensor. Each array was tested seven times for a total number of 140 insertions. During the first 10-mm insertion, no difference between the four models was observed. From 10- to 24-mm insertion, the 0.5-mm distal diameter array presented higher insertion forces than the drug-free 0.4-mm distal diameter arrays, with or without DXM. Friction forces for drug-free 0.4-mm distal diameter array and 0.4-mm distal diameter DXM eluded arrays were similar on all insertion lengths. Incorporation of DXM in silicone for cochlear implant design does not change electrode array insertion forces. It does not raise the risk of trauma during array insertion, making it suitable for long-term in situ administration to the cochlea.
A natural allele of Nxf1/TAP supresses retrovirus insertional mutations
Floyd, Jennifer A.; Gold, David A.; Concepcion, Dorothy; Poon, Tiffany H.; Wang, Xiaobo; Keithley, Elizabeth; Chen, Dan; Ward, Erica J.; Chinn, Steven B.; Friedman, Rick A.; Yu, Hon-Tsen; Moriwaki, Kazuo; Shiroishi, Toshihiko; Hamilton, Bruce A.
2009-01-01
Endogenous retroviruses have shaped the evolution of mammalian genomes. Host genes that control the effects of retrovirus insertions are therefore of great interest. The Modifier-of-vibrator-1 locus controls level of correctly processed mRNA from genes mutated by endogenous retrovirus insertions into introns, including the pitpnvb tremor mutation and the Eya1BOR model of human branchiootorenal syndrome. Positional complementation cloning identifies Mvb1 as the nuclear export factor Nxf1, providing an unexpected link between mRNA export receptor and pre-mRNA processing. Population structure of the suppressing allele in wild M. m. castaneus suggests selective advantage. A congenic Mvb1CAST allele is a useful tool for modifying gene expression from existing mutations and could be used to manipulate engineered mutations containing retroviral elements. PMID:14517553
Leak or Fistula After Sleeve Gastrectomy: Treatment with Pigtail Drain by the Rendezvous Technique.
Soufron, Jacques
2015-10-01
After a sleeve gastrectomy, a leak or fistula is a serious complication. Laparoscopic drainage, drainage under US or CT scan control, or endoscopic insertion of a stent can be used, but a major re-operation is sometimes unavoidable. Endoscopic drainage with a pigtail catheter could give more success and fewer complications, but the insertion of the drain is not always possible nor does it always provide a perfect drainage. If a laparoscopic second look appears necessary, it is possible to insert a pigtail drain laparoscopically, but under endoscopic control, ensuring a correct positioning of the drain both in the peritoneal cavity and in the gastric tube. This simultaneous "rendezvous" technique could combine in this situation the advantages of purely surgical techniques and of purely endoscopic or image-guided techniques.
Research on temperature control and influence of the vacuum tubes with inserted tubes solar heater
NASA Astrophysics Data System (ADS)
Xiao, L. X.; He, Y. T.; Hua, J. Q.
2017-11-01
A novel snake-shape vacuum tube with inserted tubes solar collector is designed in this paper, the heat transfer characteristics of the collector are analyzed according to its structural characteristics, and the influence of different working temperature on thermal characteristics of the collector is studied. The solar water heater prototype consisting of 14 vacuum tubes with inserted tubes is prepared, and the hot water storage control subsystem is designed by hysteresis comparison algorithm. The heat characteristic of the prototype was experimentally studied under hot water output temperature of 40-45°C, 50-55°C and 60-65°C. The daily thermal efficiency was 64%, 50% and 46%, respectively. The experimental results are basically consistent with the theoretical analysis.
Braun, Barbara I; Kritchevsky, Stephen B; Wong, Edward S; Solomon, Steve L; Steele, Lynn; Richards, Cheryl L; Simmons, Bryan P
2003-12-01
To describe the conceptual framework and methodology of the Evaluation of Processes and Indicators in Infection Control (EPIC) study and present results of CVC insertion characteristics and organizational practices for preventing BSIs. The goal of the EPIC study was to evaluate relationships among processes of care, organizational characteristics, and the outcome of BSI. This was a multicenter prospective observational study of variation in hospital practices related to preventing CVC-associated BSIs. Process of care information (eg, barrier use during insertions and experience of the inserting practitioner) was collected for a random sample of approximately 5 CVC insertions per month per hospital during November 1998 to December 1999. Organization demographic and practice information (eg, surveillance activities and staff and ICU nurse staffing levels) was also collected. Medical, surgical, or medical-surgical ICUs from 55 hospitals (41 U.S. and 14 international sites). Process information was obtained for 3,320 CVC insertions with an average of 58.2 (+/- 16.1) insertions per hospital. Fifty-four hospitals provided policy and practice information. Staff spent an average of 13 hours per week in study ICU surveillance. Most patients received nontunneled, multiple lumen CVCs, of which fewer than 25% were coated with antimicrobial material. Regarding barriers, most clinicians wore masks (81.5%) and gowns (76.8%); 58.1% used large drapes. Few hospitals (18.1%) used an intravenous team to manage ICU CVCs. Substantial variation exists in CVC insertion practice and BSI prevention activities. Understanding which practices have the greatest impact on BSI rates can help hospitals better target improvement interventions.
Huang, Allen R; Redpath, Calum J; van Walraven, Carl
2015-04-28
Cholinesterase inhibitors are used to treat the symptoms of dementia and can theoretically cause bradycardia. Previous studies suggest that patients taking these medications have an increased risk of undergoing pacemaker insertion. Since these drugs have a marginal impact on patient outcomes, it might be preferable to change drug treatment rather than implant a pacemaker. This population-based study determined the association of people with dementia exposed to cholinesterase inhibitor medication and pacemaker insertion. We used data from the Ontario health administrative databases from January 1, 1993 to June 30, 2012. We included all community-dwelling seniors who had a code for dementia and were exposed to cholinesterase inhibitors (donezepil, galantamine, and rivastigmine) and/or drugs used to treat co-morbidities of hypertension, diabetes, depression and hypothyroidism. We controlled for exposure to anti-arrhythmic drugs. Observation started at first exposure to any medication and continued until the earliest of pacemaker insertion, death, or end of study. 2,353,909 people were included with 96,000 (4.1%) undergoing pacemaker insertion during the observation period. Case-control analysis showed that pacemaker patients were less likely to be coded with dementia (unadjusted OR 0.42 [95%CI 0.41-0.42]) or exposed to cholinesterase inhibitors (unadjusted OR 0.39 [95%CI 0.37-0.41]). That Cohort analysis showed patients with dementia taking cholinesterase inhibitors had a decreased risk of pacemaker insertion (unadj-HR 0.58 [0.55-0.61]). Adjustment for patient age, sex, and other medications did not notably change results, as did restricting the analysis to incident users. Patients taking cholinesterase inhibitors rarely undergo, and have a significantly reduced risk of, cardiac pacemaker insertion.
Zaballos, Matilde; Bastida, Emilia; Agustí, Salomé; Portas, Maite; Jiménez, Consuelo; López-Gil, Maite
2015-10-06
A new supraglottic device, the LMA-Supreme™, has recently become available for clinical use. Information on anaesthetic and co-adjuvant requirements for insertion of the LMA-Supreme™ is limited. The present study aimed to evaluate the optimal effect-site concentration of propofol in 50 % (EC50) of adults necessary for successful insertion of the LMA-Supreme™ and to examine remifentanil's effect on propofol requirements. Fifty-eight elective patients (aged 18-60 years; ASA (American Society Anaesthesiologists) physical status classification I and II) scheduled for day surgery were randomly assigned to one of two groups: propofol with saline or propofol with remifentanil. Anaesthesia was induced by target-controlled infusion according to predetermined effect-site concentrations of propofol and remifentanil (5 ng.mL(-1)). The EC50 was calculated using Dixon's up-and-down method. Ten minutes following drug administration, LMA-Supreme™ insertion was attempted without the use of muscle relaxant drugs. In the propofol + saline group, the EC50 of propofol required for LMA-Supreme™ insertion was 6.32 ± 0.67 μg.mL(-1) (95 % CI, 5.69-6.94 μg.mL(-1)). With the addition of remifentanil at an effect-site concentration of 5 ng.mL(-1), the EC50 of propofol required for LMA-Supreme™ insertion was 2.50 ± 0.80 μg.mL(-1) (95 % CI, 1.82-3.17 μg.mL(-1); p < 0.0001). The propofol requirement for smooth insertion of the LMA-Supreme™ was 60 % less when remifentanil (5 ng.mL(-1)) was co-administered. Identified as NCT01974648 at www.clinicaltrials.gov .
Acute changes associated with electrode insertion measured with optical coherence microscopy
NASA Astrophysics Data System (ADS)
Hammer, Daniel X.; Lozzi, Andrea; Boretsky, Adam; Agrawal, Anant; Welle, Cristin G.
2016-03-01
Despite advances in functional neural imaging, penetrating microelectrodes provide the most direct interface for the extraction of neural signals from the nervous system and are a critical component of many high degree-of-freedom braincomputer interface devices. Electrode insertion is a traumatic event that elicits a complex neuroinflammatory response. In this investigation we applied optical coherence microscopy (OCM), particularly optical coherence angiography (OCA), to characterize the immediate tissue response during microelectrode insertion. Microelectrodes of varying dimension and footprint (one-, two-, and four-shank) were inserted into mouse motor cortex beneath a window after craniotomy surgery. The microelectrodes were inserted in 3-4 steps at 15-20°, with approximately 250 μm linear insertion distance for each step. Before insertion and between each step, OCM datasets were collected, including for quantitative capillary velocimetry. A cohort of control animals without microelectrode insertion was also imaged over a similar time period (2-3 hours). Mechanical tissue deformation was observed in all the experimental animals. The quantitative angiography results varied across animals, and were not correlated with device dimensions. In some cases, localized flow drop-out was observed in a small region surrounding the electrode, while in other instances a global disruption in flow occurred, perhaps as a result of large vessel compression caused by mechanical pressure. OCM is a tool that can be used in various neurophotonics applications, including quantification of the neuroinflammatory response to penetrating electrode insertion.
A proposed model membrane and test method for microneedle insertion studies.
Larrañeta, Eneko; Moore, Jessica; Vicente-Pérez, Eva M; González-Vázquez, Patricia; Lutton, Rebecca; Woolfson, A David; Donnelly, Ryan F
2014-09-10
A commercial polymeric film (Parafilm M(®), a blend of a hydrocarbon wax and a polyolefin) was evaluated as a model membrane for microneedle (MN) insertion studies. Polymeric MN arrays were inserted into Parafilm M(®) (PF) and also into excised neonatal porcine skin. Parafilm M(®) was folded before the insertions to closely approximate thickness of the excised skin. Insertion depths were evaluated using optical coherence tomography (OCT) using either a force applied by a Texture Analyser or by a group of human volunteers. The obtained insertion depths were, in general, slightly lower, especially for higher forces, for PF than for skin. However, this difference was not a large, being less than the 10% of the needle length. Therefore, all these data indicate that this model membrane could be a good alternative to biological tissue for MN insertion studies. As an alternative method to OCT, light microscopy was used to evaluate the insertion depths of MN in the model membrane. This provided a rapid, simple method to compare different MN formulations. The use of Parafilm M(®), in conjunction with a standardised force/time profile applied by a Texture Analyser, could provide the basis for a rapid MN quality control test suitable for in-process use. It could also be used as a comparative test of insertion efficiency between candidate MN formulations. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Hong, Wei-Hsien; Lee, Yung-Hui; Chen, Hsieh-Ching; Pei, Yu-Cheng; Wu, Ching-Yi
2005-12-01
The possible negative effects of high-heeled shoes on subjective comfort perception and objective biomechanical assessment have been noted. Although shoe inserts have been widely applied in footwear to increase comfort and to reduce the frequency of movement-related injury, no study has attempted to identify insert effectiveness in high heels. The purpose of this study was to determine the effects of heel height and shoe inserts on comfort and biomechanics as represented by plantar pressure and ground reaction force (GRF). Twenty young female adults performed the test conditions formed by the cross-matching of shoe inserts (shoe without insert and shoe with total contact insert [TCI]) and heel height (a flat, a low heel [3.8 cm] and a high heel [7.6 cm]). Two-way analyses of variance for repeated measures design were used to test condition effects on comfort rating, plantar pressure, and GRF during gait. To determine the biomechanical variables that can predict comfort, a multiple linear regression with stepwise method was done. The results showed that discomfort increased with heel height. In high heels, the plantar pressure in the heel and midfoot shifted to the medial forefoot, and the vertical and anteroposterior GRF increased. Use of the TCI reduced the peak pressure in the medial forefoot. Interestingly, the effectiveness of the TCI was greater in the higher heels than in the lower heels and in flat heels. The peak pressure in the medial forefoot, impact force, and the first peak vertical GRF could explain 75.6% of the variance of comfort in high-heeled gait. These findings suggest that higher heels result in decreased comfort, which can be reflected by both the subjective rating scale and biomechanical variables. Use of a TCI altered the biomechanics and therefore improved the comfort in high-heeled shoes.
Sound Absorption of a 2DOF Resonant Liner with Negative Bias Flow
NASA Technical Reports Server (NTRS)
Ahuja, K. K.; Cataldi, P.; Gaeta, R. J., Jr.; Jones, Mike (Technical Monitor)
2000-01-01
This report describes an experimental study conducted to determine the effect of negative bias flow on the sound absorption of a two degree-of-freedom liner. The backwall for the liner was designed to act as a double-Helmholtz resonator so as to act as a hard wall at all frequencies except at its resonant frequencies. All normal incident impedance data presented herein was acquired in an impedance tube. The effect of bias flow is investigated for a buried septum porosity of 2% and 19.5% for bias flow orifice mach numbers up to 03 11. As a porous backwall is needed for the flow to pass through, the effect of bias flow on this backwall all had to be evaluated first. The bias flow appears to modify the resistance and reactance of the backwall alone at lower frequencies up to about 2 kHz, with marginal effects at higher frequencies. Absorption coefficients close to unity are achieved for a frequency range of 500-4000 Hz for the overall liner for a septum porosity of 2% and orifice mach number of 0.128. Insertion loss tests performed in a flow duct facility for grazing flow Mach numbers up to 0.2 and septum mach numbers up to 0.15 showed that negative bias flow can increase insertion loss by as much as 10 dB at frequencies in the range of 500 - 1400 Hz compared to no grazing flow. The effectiveness of the negative bias flow is diminished as the grazing flow velocity is increased.
Durham, Marcus D; Buchacz, Kate; Richardson, Jim; Yang, DerShung; Wood, Kathy; Yangco, Bienvenido; Brooks, John T
2013-07-01
Recent US data on unsafe sexual behaviors among viremic HIV-infected men who have sex with men (MSM) are limited. Using data abstracted from medical records of the participants in the HIV Outpatient Study (HOPS) and a supplemental behavioral survey, we assessed the frequency of high-risk sexual practices among HIV-infected MSM in care and examined the factors associated with risky sexual practices. We also compared the frequency of unprotected anal sex (UAS) with HIV-negative or unknown serostatus partners among viremic (HIV viral load ≥400 copies per milliliter) vs virologically suppressed (HIV viral load <400 copies per milliliter) MSM. Among 902 HIV-infected MSM surveyed, 704 (78%) reported having sex in the past 6 months, of whom 54% reported UAS (37% insertive, 42% receptive) and 40% UAS with a male partner who was HIV-negative or of unknown serostatus (24% insertive, 31% receptive). In multivariable regression with an outcome of engaging in any UAS with a male partner who was HIV-negative or of unknown serostatus, MSM aged <50 years, who reported injection drug use risk, had ≥2 sex partners, and who disclosed their HIV status to some but not to all of their sex partners were more likely to report this practice. Among MSM who reported any UAS, 15% were viremic; frequency of the UAS did not differ between viremic and virologically suppressed MSM. The high frequency of UAS with HIV-negative or unknown-status partners among HIV-infected MSM in care suggests the need for targeted prevention strategies for this population.
Unique transposon landscapes are pervasive across Drosophila melanogaster genomes
Rahman, Reazur; Chirn, Gung-wei; Kanodia, Abhay; Sytnikova, Yuliya A.; Brembs, Björn; Bergman, Casey M.; Lau, Nelson C.
2015-01-01
To understand how transposon landscapes (TLs) vary across animal genomes, we describe a new method called the Transposon Insertion and Depletion AnaLyzer (TIDAL) and a database of >300 TLs in Drosophila melanogaster (TIDAL-Fly). Our analysis reveals pervasive TL diversity across cell lines and fly strains, even for identically named sub-strains from different laboratories such as the ISO1 strain used for the reference genome sequence. On average, >500 novel insertions exist in every lab strain, inbred strains of the Drosophila Genetic Reference Panel (DGRP), and fly isolates in the Drosophila Genome Nexus (DGN). A minority (<25%) of transposon families comprise the majority (>70%) of TL diversity across fly strains. A sharp contrast between insertion and depletion patterns indicates that many transposons are unique to the ISO1 reference genome sequence. Although TL diversity from fly strains reaches asymptotic limits with increasing sequencing depth, rampant TL diversity causes unsaturated detection of TLs in pools of flies. Finally, we show novel transposon insertions negatively correlate with Piwi-interacting RNA (piRNA) levels for most transposon families, except for the highly-abundant roo retrotransposon. Our study provides a useful resource for Drosophila geneticists to understand how transposons create extensive genomic diversity in fly cell lines and strains. PMID:26578579
[NEOCAT, surveillance network of catheter-related bloodstream infections in neonates: 2010 data].
L'Hériteau, F; Lacavé, L; Leboucher, B; Decousser, J-W; De Chillaz, C; Astagneau, P; Aujard, Y
2012-09-01
The NEOCAT surveillance network was implemented in 2006 in order to address catheter-associated bloodstream infections (BSIs) in neonates. The results for 2010 surveillance are presented herein. Neonatal intensive care units (NICUs) participated in the study on a voluntary basis. Umbilical catheters (UCs) and central venous catheters (CVCs) were analyzed separately. In 2010, 26NICUs participated. Overall, 2953 neonates were included (median weight, 1550 g; median gestational age, 32 weeks). These neonates had 2551UCs (median insertion duration, 4 days) and 2147CVCs (median insertion duration, 12 days). Thirty-three BSIs associated with UCs were reported, yielding a 2.9/1000UC-day incidence density, 95% confidence interval (95%CI) (1.9-3.8). UC-associated BSIs appeared after a median period of 5 days after UC insertion. The main microorganism isolated from blood cultures was coagulase negative staphylococci (CNS, n=27), S. aureus (n=3), and Enterobacteriaceae (n=5). Three hundred and six CVC-associated BSIs were recorded, yielding a 11.2/1000 CVC-day incidence density (95%CI, 10.0-12.5). These BSIs occurred after a median period of 12 days after CVC insertion. The main microorganisms were CNS (83%), S. aureus (6%), and Enterobacteriaceae (5%). The NEOCAT network provides a useful benchmark for participating wards. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Bertani, Laura; Carone, Maria; Caricati, Luca; Demaria, Serena; Fantuzzi, Silvia; Guarasci, Alessandro; Pirazzoli, Luca
2016-11-22
The peripherally inserted central catheters (PICC) have become an alternative to the traditional CVC. PICCs are usually inserted by trained nurses who decided to attend and complete a special training on PICC insertion and management. The present work aimed to investigate the intention of using PICC in a sample of hospital-based nurses using the theory of planned behavior as theoretical framework. A cross-sectional design was used in which a questionnaire was delivered to 199 nurses. According to the theory of planned behavior, the attitude toward the use of PICC, subjective norms and perceived self-efficacy predicted the intention to use PICC. Contrary to the expectations, the effect of subjective norms on intention to use PICC was mediated by attitude and self-efficacy. Finally, age of participants was negatively related to the intention to use the PICC. The theory of planned behavior offers a useful framework to explain nurses' intention to use PICC. Shared norms favoring the use of PICC seem to increase both nurse's positive attitudes and self-efficacy whit respect to the use of these devices. Thus, it appears that to train professionals individually does not necessarily results in an increased use of PICC.
Storck, Claudio; Gehrer, Raphael; Hofer, Michael; Neumayer, Bernhard; Stollberger, Rudolf; Schumacher, Ralf; Gugatschka, Markus; Friedrich, Gerhard; Wolfensberger, Markus
2012-01-01
Laryngeal electromyography (LEMG) is an important tool for the assessment of laryngeal nerve and muscle functioning. The purpose of the study was to determine electrode insertion angle and insertion depth for the various laryngeal muscles. Twenty-three cadaver larynges were examined with magnetic resonance tomography (MRT) and Materialize Interactive Medical Image Control System (Leuven, Belgium) 3-dimensional (3D) imaging software. Geometrical analysis was used to calculate the electrode insertion angles. All laryngeal muscles could be identified and 3D visualized on MRT scans. Although the insertion angles were the same in male and female larynges, the insertion depth was significantly larger in male than in female larynges (P<0.05). Of particular clinical importance is the fact that the electrode has to be directed lateral and upward for the thyroarytenoid muscle but lateral and downward for the lateral cricoarytenoid muscle (insertion point=midline lower border of the thyroid). This is the first study that analyzes electrode insertion angles and insertion depths for each laryngeal muscle using 3D imaging. We hope that the information gained from this study will help clinicians performing LEMG to localize the individual laryngeal muscles. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Bagheri-Nesami, Masoumeh; Espahbodi, Fatemeh; Nikkhah, Attieh; Shorofi, Seyed Afshin; Charati, Jamshid Yazdani
2014-02-01
This study sought to determine the effects of lavender aromatherapy on pain following needle insertion into a fistula in patients undergoing hemodialysis. This is a randomized controlled clinical trial in which 92 patients undergoing hemodialysis with arteriovenous fistulas were randomly divided into two groups. The experimental-group patients inhaled lavender essence with a concentration of 10% for 5 min during 3 hemodialysis sessions, while the control-group patients received aromatherapy free of lavender essence. The mean VAS pain intensity score in the experimental and control groups before the intervention was 3.78 ± 0.24 and 4.16 ± 0.32, respectively (p = 0.35). The mean VAS pain intensity score in the experimental and control groups after three aromatherapy sessions was 2.36 ± 0.25 and 3.43 ± 0.31, respectively (p = 0.009). Lavender aromatherapy may be an effective technique to reduce pain following needle insertion into a fistula in hemodialysis patients. Copyright © 2013 Elsevier Ltd. All rights reserved.
Control of Oscillatory Thermocapillary Convection in Microgravity
NASA Technical Reports Server (NTRS)
Skarda, Ray
1998-01-01
This project focused on the generation and suppression of oscillatory thermocapillary convection in a thin liquid layer. The bulk of the research was experimental in nature, some theoretical work was also done. ne first phase of this research generated, for the first time, the hydrothermal-wave instability predicted by Smith and Davis in 1983. In addition, the behavior of the fluid layer under a number of conditions was investigated and catalogued. A transition map for the instability of buoyancy-thermocapillary convection was prepared which presented results in terms of apparatus-dependent and apparatus-independent parameters, for ease of comparison with theoretical results. The second phase of this research demonstrated the suppression of these hydrothermal waves through an active, feed-forward control strategy employing a CO2 laser to selectively heat lines of negative disturbance temperature on the free surface of the liquid layer. An initial attempt at this control was only partially successful, employing a thermocouple inserted slightly below the free surface of the liquid to generate the control scheme. Subsequent efforts, however, were completely successful in suppressing oscillations in a portion of the layer by utilizing data from an infrared image of the free surface to compute hydrothermal-wave phase speeds and, using these, to tailor the control scheme to each passing wave.
Li, Pan; Yang, Zhiyong; Jiang, Shan
2018-06-01
Image-guided robot-assisted minimally invasive surgery is an important medicine procedure used for biopsy or local target therapy. In order to reach the target region not accessible using traditional techniques, long and thin flexible needles are inserted into the soft tissue which has large deformation and nonlinear characteristics. However, the detection results and therapeutic effect are directly influenced by the targeting accuracy of needle steering. For this reason, the needle-tissue interactive mechanism, path planning, and steering control are investigated in this review by searching literatures in the last 10 years, which results in a comprehensive overview of the existing techniques with the main accomplishments, limitations, and recommendations. Through comprehensive analyses, surgical simulation for insertion into multi-layer inhomogeneous tissue is verified as a primary and propositional aspect to be explored, which accurately predicts the nonlinear needle deflection and tissue deformation. Investigation of the path planning of flexible needles is recommended to an anatomical or a deformable environment which has characteristics of the tissue deformation. Nonholonomic modeling combined with duty-cycled spinning for needle steering, which tracks the tip position in real time and compensates for the deviation error, is recommended as a future research focus in the steering control in anatomical and deformable environments. Graphical abstract a Insertion force when the needle is inserted into soft tissue. b Needle deflection model when the needle is inserted into soft tissue [68]. c Path planning in anatomical environments [92]. d Duty-cycled spinning incorporated in nonholonomic needle steering [64].
HORIZONTAL BEAM HOLE NO. 3. PLUG AND RADIATION DOOR HAVE ...
HORIZONTAL BEAM HOLE NO. 3. PLUG AND RADIATION DOOR HAVE BEEN REMOVED. EXPERIMENTAL APPARATUS WAS INSERTED INTO THE HOLE. NOTE VALVE CUBICLES NEAR FLOOR ON EACH SIDE OF HB-3. INL NEGATIVE NO. 3471. Unknown Photographer, 10/12/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
The effect of closed system suction on airway pressures when using the Servo 300 ventilator.
Frengley, R W; Closey, D N; Sleigh, J W; Torrance, J M
2001-12-01
To measure airway pressures during closed system suctioning with the ventilator set to three differing modes of ventilation. Closed system suctioning was conducted in 16 patients following cardiac surgery. Suctioning was performed using a 14 French catheter with a vacuum level of -500 cmH2O through an 8.0 mm internal diameter endotracheal tube. The lungs were mechanically ventilated with a Servo 300 ventilator set to one of three ventilation modes: volume-control, pressure-control or CPAP/pressure support. Airway pressures were measured via a 4 French electronic pressure transducer in both proximal and distal airways. Following insertion of the suction catheter, end-expiratory pressure increased significantly (p < 0.001) in both pressure-control and volume-control ventilation. This increase was greatest (p = 0.018) in volume-control mode (2.7 +/- 1.7 cmH2O). On performing a five second suction, airway pressure decreased in all modes, however the lowest airway pressure in volume-control mode (-4.9 +/- 4.0 cmH2O) was significantly (p = 0.001) less than the lowest airway pressure recorded in either pressure-control (0.8 +/- 1.9 cmH2O) or CPAP/pressure support (0.4 +/- 2.8 cmH2O) modes. In CPAP/pressure support mode, 13 of the 16 patients experienced a positive pressure 'breath' at the end of suctioning with airway pressures rising to 21 +/- 1.6 cmH2O. Closed system suctioning in volume control ventilation may result in elevations of end-expiratory pressure following catheter insertion and subatmospheric airway pressures during suctioning. Pressure control ventilation produces less elevation of end-expiratory pressure following catheter insertion and is less likely to be associated with subatmospheric airway pressures during suctioning. CPAP/pressure support has no effect on end-expiratory pressure following catheter insertion and subatmospheric airway pressures are largely avoided during suctioning.
Will, Elke; Bailey, Jeff; Schuesler, Todd; Modlich, Ute; Balcik, Brenden; Burzynski, Ben; Witte, David; Layh-Schmitt, Gerlinde; Rudolph, Cornelia; Schlegelberger, Brigitte; von Kalle, Christof; Baum, Christopher; Sorrentino, Brian P; Wagner, Lars M; Kelly, Patrick; Reeves, Lilith; Williams, David A
2007-04-01
Although retroviral vectors are one of the most widely used vehicles for gene transfer, there is no uniformly accepted pre-clinical model defined to assess their safety, in particular their risk related to insertional mutagenesis. In the murine pre-clinical study presented here, 40 test and 10 control mice were transplanted with ex vivo manipulated bone marrow cells to assess the long-term effects of the transduction of hematopoietic cells with the retroviral vector MSCV-MGMT(P140K)wc. Test mice had significant gene marking 8-12 months post-transplantation with an average of 0.93 vector copies per cell and 41.5% of peripheral blood cells expressing the transgene MGMT(P140K), thus confirming persistent vector expression. Unexpectedly, six test mice developed malignant lymphoma. No vector was detected in the tumor cells of five animals with malignancies, indicating that the malignancies were not caused by insertional mutagenesis or MGMT(P140K) expression. Mice from a concurrent study with a different transgene also revealed additional cases of vector-negative lymphomas of host origin. We conclude that the background tumor formation in this mouse model complicates safety determination of retroviral vectors and propose an improved study design that we predict will increase the relevance and accuracy of interpretation of pre-clinical mouse studies.
Nycz, Christopher J; Gondokaryono, Radian; Carvalho, Paulo; Patel, Nirav; Wartenberg, Marek; Pilitsis, Julie G; Fischer, Gregory S
2017-09-01
The use of magnetic resonance imaging (MRI) for guiding robotic surgical devices has shown great potential for performing precisely targeted and controlled interventions. To fully realize these benefits, devices must work safely within the tight confines of the MRI bore without negatively impacting image quality. Here we expand on previous work exploring MRI guided robots for neural interventions by presenting the mechanical design and assessment of a device for positioning, orienting, and inserting an interstitial ultrasound-based ablation probe. From our previous work we have added a 2 degree of freedom (DOF) needle driver for use with the aforementioned probe, revised the mechanical design to improve strength and function, and performed an evaluation of the mechanism's accuracy and effect on MR image quality. The result of this work is a 7-DOF MRI robot capable of positioning a needle tip and orienting it's axis with accuracy of 1.37 ± 0.06 mm and 0.79° ± 0.41°, inserting it along it's axis with an accuracy of 0.06 ± 0.07 mm , and rotating it about it's axis to an accuracy of 0.77° ± 1.31°. This was accomplished with no significant reduction in SNR caused by the robot's presence in the MRI bore, ≤ 10.3% reduction in SNR from running the robot's motors during a scan, and no visible paramagnetic artifacts.
Biofilm Quantification on Nasolacrimal Silastic Stents After Dacryocystorhinostomy.
Murphy, Jae; Ali, Mohammed Javed; Psaltis, Alkis James
2015-01-01
Biofilms are now recognized as potential factors in the pathogenesis of chronic inflammatory and infective diseases. The aim of this study was to examine the presence of biofilms and quantify their biomass on silastic nasolacrimal duct stents inserted after dacryocystorhinostomy (DCR). A prospective study was performed on a series of patients undergoing DCR with O'Donoghue stent insertion. After removal, the stents were subjected to biofilm analysis using standard protocols of confocal laser scanning microscopy (CLSM) and scanning electron microscopy. These stents were compared against negative controls and positive in vitro ones established using Staphylococcus aureus strain ATCC 25923. Biofilm quantification was performed using the COMSTAT2 software and the total biofilm biomass was calculated. A total of nine consecutive patient samples were included in this prospective study. None of the patients had any evidence of postoperative infection. All the stents demonstrated evidence of biofilm formation using both imaging modalities. The presence of various different sized organisms within a common exopolysaccharide matrix on CLSM suggested the existence of polymicrobial communities. The mean biomass of patient samples was 0.9385 μm³/μm² (range: 0.3901-1.9511 μm³/μm²). This is the first study to report the quantification of biomass on lacrimal stents. The presence of biofilms on lacrimal stents after DCR is a common finding but this need not necessarily translate to postoperative clinical infection.
Continuous air monitor filter changeout apparatus
Rodgers, John C [Santa Fe, NM
2008-07-15
An apparatus and corresponding method for automatically changing out a filter cartridge in a continuous air monitor. The apparatus includes: a first container sized to hold filter cartridge replacements; a second container sized to hold used filter cartridges; a transport insert connectively attached to the first and second containers; a shuttle block, sized to hold the filter cartridges that is located within the transport insert; a transport driver mechanism means used to supply a motive force to move the shuttle block within the transport insert; and, a control means for operating the transport driver mechanism.
Role of nanorods insertion layer in ZnO-based electrochemical metallization memory cell
NASA Astrophysics Data System (ADS)
Mangasa Simanjuntak, Firman; Singh, Pragya; Chandrasekaran, Sridhar; Juanda Lumbantoruan, Franky; Yang, Chih-Chieh; Huang, Chu-Jie; Lin, Chun-Chieh; Tseng, Tseung-Yuen
2017-12-01
An engineering nanorod array in a ZnO-based electrochemical metallization device for nonvolatile memory applications was investigated. A hydrothermally synthesized nanorod layer was inserted into a Cu/ZnO/ITO device structure. Another device was fabricated without nanorods for comparison, and this device demonstrated a diode-like behavior with no switching behavior at a low current compliance (CC). The switching became clear only when the CC was increased to 75 mA. The insertion of a nanorods layer induced switching characteristics at a low operation current and improve the endurance and retention performances. The morphology of the nanorods may control the switching characteristics. A forming-free electrochemical metallization memory device having long switching cycles (>104 cycles) with a sufficient memory window (103 times) for data storage application, good switching stability and sufficient retention was successfully fabricated by adjusting the morphology and defect concentration of the inserted nanorod layer. The nanorod layer not only contributed to inducing resistive switching characteristics but also acted as both a switching layer and a cation diffusion control layer.
Schmidt, Heather-Marie A; Andres, Sönke; Kaakoush, Nadeem O; Engstrand, Lars; Eriksson, Lena; Goh, Khean-Lee; Fock, Kwong Ming; Hilmi, Ida; Dhamodaran, Subbiah; Forman, David; Mitchell, Hazel
2009-01-01
Background The putative H. pylori pathogenicity-associated factor dupA has been associated with IL-8 induction in vitro, and duodenal ulcer (DU) and gastric cancer (GC) development in certain populations, but this association is inconsistent between studies. We aimed to investigate dupA prevalence in clinical isolates from Sweden, Australia and from ethnic Chinese, Indians and Malays resident in Malaysia and Singapore and to examine the association with DU and GC. In addition we investigated the sequence diversity between isolates from these diverse groups and compared the level of IL-8 secretion in isolates possessing and lacking dupA. Methods PCR primers were designed to amplify over the C/T insertion denoting a continuous dupA. PCR products from 29 clinical isolates were sequenced and compared with sequences from three additional strains obtained from GenBank. Clinical isolates from 21 Malaysian patients (8 dupA-positive, 14 dupA-negative) were assessed for their ability to induce IL-8 in AGS cells in vitro. Statistical analysis was performed using Fisher's exact test. Results The prevalence of dupA in isolates from Swedish functional dyspepsia (FD) control patients (65%, 13/20) was higher and in isolates from Indian FD patients (7.1%, 3/42) was lower as compared with isolates from Chinese (28.9%, 13/49, P = 0.005, P = 0.025), Malay (35.7%, 5/14, P = 0.16, P = 0.018) and Australian (37.8%, 17/45, P = 0.060, P < 0.001) FD patients. dupA was associated with DU and GC development in Chinese with 62.5% (10/16) and 54.6% (12/22) of isolates possessing dupA respectively as compared with FD controls (28.9%) (P = 0.015, P = 0.032). No significant difference in prevalence of dupA between FD controls, DU (63.6%, 7/11) and GC (61.9%, 13/21) cases (P = 1.000) was observed in the Swedish population. Sequence analysis revealed a pairwise variation of 1.9% and all isolates possessed the C/T insertion. The average IL-8 induction was 1330 pg/mL for dupA-positive isolates and 1378 pg/mL for dupA-negative isolates. Conclusion Although dupA is highly conserved when present, we identified no consistent association between dupA and DU or GC development across the ethnic groups investigated, with the dupA prevalence in control groups varying significantly. Our results would suggest that in the clinical isolates investigated dupA is not associated with IL-8 induction in vitro. PMID:19338650
Schmidt, Heather-Marie A; Andres, Sönke; Kaakoush, Nadeem O; Engstrand, Lars; Eriksson, Lena; Goh, Khean-Lee; Fock, Kwong Ming; Hilmi, Ida; Dhamodaran, Subbiah; Forman, David; Mitchell, Hazel
2009-03-11
The putative H. pylori pathogenicity-associated factor dupA has been associated with IL-8 induction in vitro, and duodenal ulcer (DU) and gastric cancer (GC) development in certain populations, but this association is inconsistent between studies. We aimed to investigate dupA prevalence in clinical isolates from Sweden, Australia and from ethnic Chinese, Indians and Malays resident in Malaysia and Singapore and to examine the association with DU and GC. In addition we investigated the sequence diversity between isolates from these diverse groups and compared the level of IL-8 secretion in isolates possessing and lacking dupA. PCR primers were designed to amplify over the C/T insertion denoting a continuous dupA. PCR products from 29 clinical isolates were sequenced and compared with sequences from three additional strains obtained from GenBank. Clinical isolates from 21 Malaysian patients (8 dupA-positive, 14 dupA-negative) were assessed for their ability to induce IL-8 in AGS cells in vitro. Statistical analysis was performed using Fisher's exact test. The prevalence of dupA in isolates from Swedish functional dyspepsia (FD) control patients (65%, 13/20) was higher and in isolates from Indian FD patients (7.1%, 3/42) was lower as compared with isolates from Chinese (28.9%, 13/49, P = 0.005, P = 0.025), Malay (35.7%, 5/14, P = 0.16, P = 0.018) and Australian (37.8%, 17/45, P = 0.060, P < 0.001) FD patients. dupA was associated with DU and GC development in Chinese with 62.5% (10/16) and 54.6% (12/22) of isolates possessing dupA respectively as compared with FD controls (28.9%) (P = 0.015, P = 0.032). No significant difference in prevalence of dupA between FD controls, DU (63.6%, 7/11) and GC (61.9%, 13/21) cases (P = 1.000) was observed in the Swedish population. Sequence analysis revealed a pairwise variation of 1.9% and all isolates possessed the C/T insertion. The average IL-8 induction was 1330 pg/mL for dupA-positive isolates and 1378 pg/mL for dupA-negative isolates. Although dupA is highly conserved when present, we identified no consistent association between dupA and DU or GC development across the ethnic groups investigated, with the dupA prevalence in control groups varying significantly. Our results would suggest that in the clinical isolates investigated dupA is not associated with IL-8 induction in vitro.
NASA Astrophysics Data System (ADS)
Takano, Naoki; Tachikawa, Hiroto; Miyano, Takaya; Nishiyabu, Kazuaki
Aiming at the practical use of polyethylene glycol (PEG) microneedles for transdermal drug delivery system (DDS), a testing apparatus for their insertion into cultured human skin has been developed. To simulate the variety of conditions of human skin, biaxial tension can be applied to the cultured human skin. An adopted testing scheme to apply and control the biaxial tension is similar to the deep-draw forming technique. An attention was also paid to the short-time setup of small, thin and wet cultured skin. One dimensional array with four needles was inserted and influence of tension was discussed. It was found that tension, deflection of skin during insertion and original curvature of skin are the important parameters for microneedles array design.
Stewart, J M
2000-02-01
Invasive arterial monitoring alters autonomic tone. The effects of intravenous (i.v.) insertion are less clear. The author assessed the effects of i.v. insertion on autonomic activity in patients aged 11 to 19 years prior to head-up tilt by measuring heart rate, blood pressure, heart rate variability, blood pressure variability, and baroreceptor gain before and after i.v. insertion with continuous electrocardiography and arterial tonometry in patients with orthostatic tachycardia syndrome (OTS, N = 21), in patients who experienced simple fainting (N = 14), and in normal control subjects (N = 6). Five-minute samples were collected after 30 minutes supine. Fifteen minutes after i.v. insertion, data were collected again. These 5-minute samples were also collected in a separate control population without i.v. insertion after 30 minutes supine and again 30 minutes later. This population included 12 patients with OTS, 13 patients who experienced simple fainting, and 6 normal control subjects. Heart rate variability included the mean RR, the standard deviation of the RR interval (SDNN), and the root mean square of successive RR differences (RMSSD). Autoregressive spectral modeling was used. Low-frequency power (LFP, 0.04-0.15 Hz), high-frequency power (HFP, 0.15-0.40 Hz), and total power (TP, 0.01-0.40 Hz) were compared. Blood pressure variability included standard deviation of systolic blood pressure, LFP, and HFP. Baroreceptor gain at low frequency and high frequency was calculated from cross-spectral transfer function magnitudes when coherence was greater than 0.5. In patients with OTS, RR (790 +/- 50 msec), SDNN (54 +/- 6 msec), RMSSD (55 +/- 5 msec), LFP (422 +/- 200 ms2/Hz), HFP (846 +/- 400 ms2/Hz), and TP (1550 +/- 320 ms2/Hz) were less than in patients who experienced simple fainting (RR, 940 +/- 50 msec; SDNN, 84 +/- 10 msec; RMSSD, 91 +/- 7 msec; LFP, 880 +/- 342 ms2/Hz; HFP, 1720 +/- 210 ms2/Hz; and TP, 3228 +/- 490 ms2/Hz) or normal control subjects (RR, 920 +/- 30 msec; SDNN, 110 +/- 29 msec; RMSSD, 120 +/- 16 msec; LFP, 1600 +/- 331 ms2/Hz; HFP, 2700 +/- 526 ms2/Hz; and TP, 5400 +/- 1017 ms2/Hz). Blood pressure and blood pressure variability were not different in any group. Standard deviation, LFP, and HFP were, respectively, 5.24 +/- 0.8 mm Hg, 1.2 +/- 0.2, and 1.5 +/- 0.3 for patients with OTS; 4.6 +/- 0.4 mm Hg, 1.2 +/- 0.2, and 1.4 +/- 0.3 for patients who experienced simple fainting; and 5.55 +/- 1.0 mm Hg, 1.4 +/- 0.2, and 1.6 +/- 0.3 for normal control subjects. Baroreceptor gain at low frequency and high frequency in patients with OTS (16 +/- 4 msec/mm Hg, 17 +/- 5) was comparable to that in patients who experienced simple fainting (33 +/- 4, 32 +/- 3) and that in normal control subjects (31 +/- 8, 37 +/- 9). Heart rate variability differed between patients with OTS and patients who experienced simple fainting or normal control subjects, and blood pressure and blood pressure variability were not different, but no parameter changed after i.v. insertion. There were no differences from the groups that did not receive i.v. insertions. Data suggest, at most, a limited effect of i.v. insertion on autonomic function in adolescents.
[Damping inserts have no load reducing effect in the fatigued state].
Melnyk, M; Gollhofer, A
2008-09-01
Overload injuries to the lower limbs may be attributed to repetitive, non-physiological load stimuli. However, these impact loads acting on the musculoskeletal can be reduced by wearing damping inserts. To date, however, there is only little evidence as to whether this positive effect can be assigned to the damping insert and, furthermore, whether this effect is detectable in states of muscle fatigue. Therefore, the influence of muscle fatigue in combination with the wearing of damping inserts was investigated in 13 subjects. The parameters examined in this study were ground reaction forces during walking and the muscular activation profile of the lower limb in the phase of initial ground contact. The results showed that neither in comparisons with and without damping inserts nor in states of muscular fatigue could significant differences were found in the ground reaction forces. Wereas, no significant differences could be detected in the investigated muscles, with and without damping inserts, preactivation in the peroneal and biceps femoris muscles were significantly earlier, in states of muscular fatigue with damping inserts, while no changes could be found in the anterior tibial, soleus, vastus lateralis and gastrocnemius muscles. The present results demonstrate that wearing damping inserts does not lead to a positive effect with regard to a reduction of the ground reaction forces. The earlier preactivation in the case of muscle fatigue with a damping insert is indicative of an increased energy expenditure which may be possibly associated with increased knee and ankle joint control. The high satisfaction concerning the comfort of wearing such inserts revealed by a questionnaire did not correlate with a reduction in loading condition. On the basis of the present results we cannot recommend the wearing of damping soft sole inserts in the context of a reduction in load condition.
Oliveira, Emileane C; Hunziker, Maria Helena
2014-07-01
In this study, we investigated whether (a) animals demonstrating the learned helplessness effect during an escape contingency also show learning deficits under positive reinforcement contingencies involving stimulus control and (b) the exposure to positive reinforcement contingencies eliminates the learned helplessness effect under an escape contingency. Rats were initially exposed to controllable (C), uncontrollable (U) or no (N) shocks. After 24h, they were exposed to 60 escapable shocks delivered in a shuttlebox. In the following phase, we selected from each group the four subjects that presented the most typical group pattern: no escape learning (learned helplessness effect) in Group U and escape learning in Groups C and N. All subjects were then exposed to two phases, the (1) positive reinforcement for lever pressing under a multiple FR/Extinction schedule and (2) a re-test under negative reinforcement (escape). A fourth group (n=4) was exposed only to the positive reinforcement sessions. All subjects showed discrimination learning under multiple schedule. In the escape re-test, the learned helplessness effect was maintained for three of the animals in Group U. These results suggest that the learned helplessness effect did not extend to discriminative behavior that is positively reinforced and that the learned helplessness effect did not revert for most subjects after exposure to positive reinforcement. We discuss some theoretical implications as related to learned helplessness as an effect restricted to aversive contingencies and to the absence of reversion after positive reinforcement. This article is part of a Special Issue entitled: insert SI title. Copyright © 2014. Published by Elsevier B.V.
In vitro modifications of the scala tympani environment and the cochlear implant array surface.
Kontorinis, Georgios; Scheper, Verena; Wissel, Kirsten; Stöver, Timo; Lenarz, Thomas; Paasche, Gerrit
2012-09-01
To investigate the influence of alterations of the scala tympani environment and modifications of the surface of cochlear implant electrode arrays on insertion forces in vitro. Research experimental study. Fibroblasts producing neurotrophic factors were cultivated on the surface of Nucleus 24 Contour Advance electrodes. Forces were recorded by an Instron 5542 Force Measurement System as three modified arrays were inserted into an artificial scala tympani model filled with phosphate-buffered saline (PBS). The recorded forces were compared to control groups including three unmodified electrodes inserted into a model filled with PBS (unmodified environment) or Healon (current practice). Fluorescence microscopy was used before and after the insertions to identify any remaining fibroblasts. Additionally, three Contour Advance electrodes were inserted into an artificial model, filled with alginate/barium chloride solution at different concentrations, while insertion forces were recorded. Modification of the scala tympani environment with 50% to 75% alginate gel resulted in a significant decrease in the insertion forces. The fibroblast-coated arrays also led to decreased forces comparable to those recorded with Healon. Fluorescence microscopy revealed fully cell-covered arrays before and partially covered arrays after the insertion; the fibroblasts on the arrays' modiolar surface remained intact. Modifications of the scala tympani's environment with 50% to 75% alginate/barium chloride and of the cochlear implant electrode surface with neurotrophic factor-producing fibroblasts drastically reduce the insertion forces. As both modifications may serve future intracochlear therapies, it is expected that these might additionally reduce possible insertion trauma. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.
Crockett, Amy H; Pickell, Lesley Bundon; Heberlein, Emily C; Billings, Deborah L; Mills, Benjie
2017-01-01
This study aims to document 6- and 12-month removal rates for women receiving the contraceptive implant inpatient postpartum versus those receiving the same contraceptive method during an outpatient visit, in a setting where postpartum inpatient long-acting reversible contraceptive (LARC) services (devices plus provider insertion costs) are reimbursed by Medicaid. We conducted a retrospective cohort study among Medicaid-enrolled women using medical record review for all women receiving the etonogestrel implant between July 1, 2007 and June 30, 2014. We compared the percentage of women with the implant removed at 6 and 12 months as well as reasons for early removal, for inpatient postpartum implant insertions vs. delayed postpartum or interval outpatient implant insertions. A total of 4% of women (34/776 insertions) had documented implant removal within 6 months post-insertion, with no difference between postpartum inpatient and outpatient (delayed postpartum or interval). A total of 12% (62/518 insertions) of women had documented implant removal within 12 months. A lower percentage of women with postpartum inpatient insertions had the implant removed at 12 months post-insertion, compared to outpatient insertions (7% vs. 14%, p=.04). After controlling for age, parity, race and body mass index, women with postpartum inpatient insertions were less likely to have the implant removed within 12 months (OR=0.44, 95% CI 0.20-0.97). The most commonly stated reason for removal was abnormal uterine bleeding, regardless of insertion timing. In a setting with a Medicaid policy that covers postpartum inpatient LARC insertion, a low percentage of women who received an implant immediately postpartum had it removed within 1 year of insertion. A Medicaid payment policy that removes institutional barriers to offering postpartum inpatient contraceptive implants to women free-of-charge may facilitate meeting women's desires and intentions to delay subsequent pregnancy, as evidenced by low removal rates up to 12 months post-insertion. Further research with women is needed to assess how these services meet their postpartum contraceptive needs and desires to postpone or prevent subsequent pregnancy. Copyright © 2016 Elsevier Inc. All rights reserved.
Power flow controller with a fractionally rated back-to-back converter
Divan, Deepakraj M.; Kandula, Rajendra Prasad; Prasai, Anish
2016-03-08
A power flow controller with a fractionally rated back-to-back (BTB) converter is provided. The power flow controller provide dynamic control of both active and reactive power of a power system. The power flow controller inserts a voltage with controllable magnitude and phase between two AC sources at the same frequency; thereby effecting control of active and reactive power flows between the two AC sources. A transformer may be augmented with a fractionally rated bi-directional Back to Back (BTB) converter. The fractionally rated BTB converter comprises a transformer side converter (TSC), a direct-current (DC) link, and a line side converter (LSC). By controlling the switches of the BTB converter, the effective phase angle between the two AC source voltages may be regulated, and the amplitude of the voltage inserted by the power flow controller may be adjusted with respect to the AC source voltages.
MTR WING, TRA604. ONE OF THE LABORATORY UNITS ALONG THE ...
MTR WING, TRA-604. ONE OF THE LABORATORY UNITS ALONG THE SOUTH SIDE WALL. NOTE SINK, CABINET, TABLE, AND HOOD UNITS. DUCT ABOVE RECEIVES CONTAMINATED AIR AND SENDS IT TO FAN HOUSE AND STACK. NOTE PARTITION WALL BEHIND WORK UNITS. THE HEALTH PHYSICS LAB WAS SIMILARLY EQUIPPED. WINDOW AT LEFT EDGE OF VIEW. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION PRINTED ON ORIGINAL NEGATIVE. INL NEGATIVE NO. 4225. Unknown Photographer, 2/13/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
A new scanning electron microscopy approach to image aerogels at the nanoscale
NASA Astrophysics Data System (ADS)
Solá, F.; Hurwitz, F.; Yang, J.
2011-04-01
A new scanning electron microscopy (SEM) technique to image poor electrically conductive aerogels is presented. The process can be performed by non-expert SEM users. We showed that negative charging effects on aerogels can be minimized significantly by inserting dry nitrogen gas close to the region of interest. The process involves the local recombination of accumulated negative charges with positive ions generated from ionization processes. This new technique made possible the acquisition of images of aerogels with pores down to approximately 3 nm in diameter using a positively biased Everhart-Thornley (ET) detector.
Jane Cassidy, Elizabeth; Vitt Meyling, Nicolai
2018-01-01
Parasite effects on host fitness and immunology are often intensity-dependent. Unfortunately, only few experimental studies on insect-parasite interactions attempt to control the level of infection, which may contribute substantial variation to the fitness or immunological parameters of interest. The tapeworm Hymenolepis diminuta—flour beetle Tenebrio molitor model—has been used extensively for ecological and evolutionary host–parasite studies. Successful establishment of H. diminuta cysticercoids in T. molitor relies on ingestion of viable eggs and penetration of the gut wall by the onchosphere. Like in other insect models, there is a lack of standardization of the infection load of cysticercoids in beetles. The aims of this study were to: (1) quantify the relationship between exposure dose and establishment success across several H. diminuta egg concentrations; and (2) test parasite establishment in beetles while experimentally manipulating host body condition and potential immune response to infection. Different egg concentrations of H. diminuta isolated from infected rat feces were fed to individual beetles 7–10 days after eclosion and beetles were exposed to starvation, wounding, or insertion of a nylon filament one hour prior to infection. We found that the establishment of cysticercoids in relation to exposure dose could be accurately predicted using a power function where establishment success was low at three lowest doses and higher at the two highest doses tested. Long-term starvation had a negative effect on cysticercoid establishment success, while insertion of a nylon filament and wounding the beetles did not have any effect compared to control treatment. Thus, our results show that parasite load may be predicted from the exposure dose within the observed range, and that the relationship between dose and parasite establishment success is able to withstand some changes in host body condition. PMID:29401652
Dhakal, Suraj; Micki Buss, Sebastian; Jane Cassidy, Elizabeth; Vitt Meyling, Nicolai; Lund Fredensborg, Brian
2018-02-03
Parasite effects on host fitness and immunology are often intensity-dependent. Unfortunately, only few experimental studies on insect-parasite interactions attempt to control the level of infection, which may contribute substantial variation to the fitness or immunological parameters of interest. The tapeworm Hymenolepis diminuta -flour beetle Tenebrio molitor model-has been used extensively for ecological and evolutionary host-parasite studies. Successful establishment of H. diminuta cysticercoids in T. molitor relies on ingestion of viable eggs and penetration of the gut wall by the onchosphere. Like in other insect models, there is a lack of standardization of the infection load of cysticercoids in beetles. The aims of this study were to: (1) quantify the relationship between exposure dose and establishment success across several H. diminuta egg concentrations; and (2) test parasite establishment in beetles while experimentally manipulating host body condition and potential immune response to infection. Different egg concentrations of H. diminuta isolated from infected rat feces were fed to individual beetles 7-10 days after eclosion and beetles were exposed to starvation, wounding, or insertion of a nylon filament one hour prior to infection. We found that the establishment of cysticercoids in relation to exposure dose could be accurately predicted using a power function where establishment success was low at three lowest doses and higher at the two highest doses tested. Long-term starvation had a negative effect on cysticercoid establishment success, while insertion of a nylon filament and wounding the beetles did not have any effect compared to control treatment. Thus, our results show that parasite load may be predicted from the exposure dose within the observed range, and that the relationship between dose and parasite establishment success is able to withstand some changes in host body condition.
Effectiveness of electrocardiographic guidance in CVAD tip placement.
Walker, Graham; Chan, Raymond J; Alexandrou, Evan; Webster, Joan; Rickard, Claire
International standard practice for the correct confirmation of the central venous access device is the chest X-ray. The intracavitary electrocardiogram-based insertion method is radiation-free, and allows real-time placement verification, providing immediate treatment and reduced requirement for post-procedural repositioning. Relevant databases were searched for prospective randomised controlled trials (RCTs) or quasi RCTs that compared the effectiveness of electrocardiogram-guided catheter tip positioning with placement using surface-anatomy-guided insertion plus chest X-ray confirmation. The primary outcome was accurate catheter tip placement. Secondary outcomes included complications, patient satisfaction and costs. Five studies involving 729 participants were included. Electrocardiogram-guided insertion was more accurate than surface anatomy guided insertion (odds ratio: 8.3; 95% confidence interval (CI) 1.38; 50.07; p=0.02). There was a lack of reporting on complications, patient satisfaction and costs. The evidence suggests that intracavitary electrocardiogram-based positioning is superior to surface-anatomy-guided positioning of central venous access devices, leading to significantly more successful placements. This technique could potentially remove the requirement for post-procedural chest X-ray, especially during peripherally inserted central catheter (PICC) line insertion.
Brewer, Megan H.; Chaudhry, Rabia; Qi, Jessica; Kidambi, Aditi; Drew, Alexander P.; Ryan, Monique M.; Subramanian, Gopinath M.; Young, Helen K.; Zuchner, Stephan; Reddel, Stephen W.; Nicholson, Garth A.; Kennerson, Marina L.
2016-01-01
With the advent of whole exome sequencing, cases where no pathogenic coding mutations can be found are increasingly being observed in many diseases. In two large, distantly-related families that mapped to the Charcot-Marie-Tooth neuropathy CMTX3 locus at chromosome Xq26.3-q27.3, all coding mutations were excluded. Using whole genome sequencing we found a large DNA interchromosomal insertion within the CMTX3 locus. The 78 kb insertion originates from chromosome 8q24.3, segregates fully with the disease in the two families, and is absent from the general population as well as 627 neurologically normal chromosomes from in-house controls. Large insertions into chromosome Xq27.1 are known to cause a range of diseases and this is the first neuropathy phenotype caused by an interchromosomal insertion at this locus. The CMTX3 insertion represents an understudied pathogenic structural variation mechanism for inherited peripheral neuropathies. Our finding highlights the importance of considering all structural variation types when studying unsolved inherited peripheral neuropathy cases with no pathogenic coding mutations. PMID:27438001
Copy number determination of genetically-modified hematopoietic stem cells.
Schuesler, Todd; Reeves, Lilith; Kalle, Christof von; Grassman, Elke
2009-01-01
Human gene transfer with gammaretroviral, murine leukemia virus (MLV) based vectors has been shown to effectively insert and express transgene sequences at a level of therapeutic benefit. However, there are numerous reports of disruption of the normal cellular processes caused by the viral insertion, even of replication deficient gammaretroviral vectors. Current gammaretroviral and lentiviral vectors do not control the site of insertion into the genome, hence, the possibility of disruption of the target cell genome. Risk related to viral insertions is linked to the number of insertions of the transgene into the cellular DNA, as has been demonstrated for replication competent and replication deficient retroviruses in experiments. At high number of insertions per cell, cell transformation due to vector induced activation of proto-oncogenes is more likely to occur, in particular since more than one transforming event is needed for oncogenesis. Thus, determination of the vector copy number in bulk transduced populations, individual colony forming units, and tissue from the recipient of the transduced cells is an increasingly important safety assay and has become a standard, though not straightforward assay, since the inception of quantitative PCR.
Sensor-less pseudo-sinusoidal drive for a permanent-magnet brushless ac motor
NASA Astrophysics Data System (ADS)
Liu, Li-Hsiang; Chern, Tzuen-Lih; Pan, Ping-Lung; Huang, Tsung-Mou; Tsay, Der-Min; Kuang, Jao-Hwa
2012-04-01
The precise rotor-position information is required for a permanent-magnet brushless ac motor (BLACM) drive. In the conventional sinusoidal drive method, either an encoder or a resolver is usually employed. For position sensor-less vector control schemes, the rotor flux estimation and torque components are obtained by complicated coordinate transformations. These computational intensive methods are susceptible to current distortions and parameter variations. To simplify the method complexity, this work presents a sensor-less pseudo-sinusoidal drive scheme with speed control for a three-phase BLACM. Based on the sinusoidal drive scheme, a floating period of each phase current is inserted for back electromotive force detection. The zero-crossing point is determined directly by the proposed scheme, and the rotor magnetic position and rotor speed can be estimated simultaneously. Several experiments for various active angle periods are undertaken. Furthermore, a current feedback control is included to minimize and compensate the torque fluctuation. The experimental results show that the proposed method has a competitive performance compared with the conventional drive manners for BLACM. The proposed scheme is straightforward, bringing the benefits of sensor-less drive and negating the need for coordinate transformations in the operating process.
Tarity, T David; Koch, Chelsea N; Burket, Jayme C; Wright, Timothy M; Westrich, Geoffrey H
2017-03-01
Adverse local tissue reaction formation has been suggested to occur with the Modular Dual Mobility (MDM) acetabular design. Few reports in the literature have evaluated fretting and corrosion damage between the acetabular shell and modular metal inserts in this modular system. We evaluated a series of 18 retrieved cobalt chromium MDM inserts for evidence of fretting and corrosion. We assessed the backsides of 18 MDM components for evidence of fretting and corrosion in polar and taper regions based on previously established methods. We collected and assessed 30 similarly designed modular inserts retrieved from metal-on-metal (MoM) total hip arthroplasties as a control. No specific pattern of fretting or corrosion was identified on the MDM inserts. Both fretting and corrosion were significantly greater in the MoM cohort than the MDM cohort, driven by higher fretting and corrosion scores in the engaged taper region of the MoM inserts. MoM components demonstrated more fretting and corrosion than MDM designs, specifically at the taper region, likely driven by differences in the taper engagement mechanism and geometry among the insert designs. The lack of significant fretting and corrosion observed in the MDM inserts are inconsistent with recent claims that this interface may produce clinically significant metallosis and adverse local tissue reactions. Copyright © 2016 Elsevier Inc. All rights reserved.
Low Li+ Insertion Barrier Carbon for High Energy Efficient Lithium-Ion Capacitor.
Lee, Wee Siang Vincent; Huang, Xiaolei; Tan, Teck Leong; Xue, Jun Min
2018-01-17
Lithium-ion capacitor (LIC) is an attractive energy-storage device (ESD) that promises high energy density at moderate power density. However, the key challenge in its design is the low energy efficient negative electrode, which barred the realization of such research system in fulfilling the current ESD technological inadequacy due to its poor overall energy efficiency. Large voltage hysteresis is the main issue behind high energy density alloying/conversion-type materials, which reduces the electrode energy efficiency. Insertion-type material though averted in most research due to the low capacity remains to be highly favorable in commercial application due to its lower voltage hysteresis. To further reduce voltage hysteresis and increase capacity, amorphous carbon with wider interlayer spacing has been demonstrated in the simulation result to significantly reduce Li + insertion barrier. Hence, by employing such amorphous carbon, together with disordered carbon positive electrode, a high energy efficient LIC with round-trip energy efficiency of 84.3% with a maximum energy density of 133 Wh kg -1 at low power density of 210 W kg -1 can be achieved.
Simulation of LV pacemaker lead in marginal vein: potential risk factors for acute dislodgement.
Zhao, Xuefeng; Burger, Mike; Liu, Yi; Das, Mithilesh K; Combs, William; Wenk, Jonathan F; Guccione, Julius M; Kassab, Ghassan S
2011-03-01
Although left ventricular (LV) coronary sinus lead dislodgement remains a problem, the risk factors for dislodgement have not been clearly defined. In order to identify potential risk factors for acute lead dislodgement, we conducted dynamic finite element simulations of pacemaker lead dislodgement in marginal LV vein. We considered factors such as mismatch in lead and vein diameters, velocity of myocardial motion, branch angle between the insertion vein and the coronary sinus, degree of slack, and depth of insertion. The results show that large lead-to-vein diameter mismatch, rapid myocardial motion, and superficial insertion are potential risk factors for lead dislodgement. In addition, the degree of slack presents either a positive or negative effect on dislodgement risk depending on the branch angle. The prevention of acute lead dislodgment can be enforced by inducing as much static friction force as possible at the lead-vein interface, while reducing the external force. If the latter exceeds the former, dislodgement will occur. The present findings underscore the major risk factors for lead dislodgment, which may improve implantation criterion and future lead design.
Trench Inserts as Long-term Barriers to Root Transmission for Control of Oak Wilt
A. Dan Wilson; D.G. Lester
2002-01-01
Physical and chemical barriers to root penetration and root grafting across trenches were evaluated for their effectiveness in improving trenches as barriers to root transmission of the oak wilt fungus in live oaks. Four trench insert materials were tested, including water-permeable Typar and Biobarrier, and water-impermeable Geomembranc of two thicknesses....
Methods and compositions for controlling gene expression by RNA processing
Doudna, Jennifer A.; Qi, Lei S.; Haurwitz, Rachel E.; Arkin, Adam P.
2017-08-29
The present disclosure provides nucleic acids encoding an RNA recognition sequence positioned proximal to an insertion site for the insertion of a sequence of interest; and host cells genetically modified with the nucleic acids. The present disclosure also provides methods of modifying the activity of a target RNA, and kits and compositions for carrying out the methods.
[Central venous catheter-related infections in critically ill patients].
Diener, J R; Coutinho, M S; Zoccoli, C M
1996-01-01
To determine incidence rate, etiology and risk factors for central venous catheter (CVC)-related infections in critically-ill patients, a prospective cohort study was conducted in the general Intensive Care Unit (ICU) of a 212 bed Hospital in Florianópolis, Brazil. Patients admitted to ICU between May 1993 and February 1994, exposed to short-term CVC, were included in the study. Quantitative skin culture at CVC insertion site, semi-quantitative CVC tip culture, quantitative hub culture, and peripheral blood-culture were done. Results were submitted to univariate and multivariate analysis. Fifty-seven catheterization periods were analysed in 51 patients. The incidence rate was 21.1% (33.1 per 1,000 catheter-days) for local infection, and 8.7% (14.1 per 1,000 catheter-days) for catheter-associated bacteremia. The skin at the insertion site was colonized in 32.7% and the hub in 29.1% of the patients respectively. Potential sources of infection were the skin in 41.2% of the cases, the hub in 29.4%, remote site in 5.9% and unknown in 23.5%. The hub was implicated in 60% of the catheter-associated bacteremias. Coagulase-negative staphylococci were the main isolates. Another intravascular device and purulence at the insertion site were independently associated with local infection. Insertion at internal jugular site and hub colonization were independently associated with bacteremia. Catheter-associated bacteremia is a major complication of central venous catheterization in critically-ill patients. Internal jugular insertion and CVC hub colonization are important risk factors for significant catheter-related infections.
Kumar, Santosh; Mapa, Koyeli; Maiti, Souvik
2014-03-18
miRNAs are some of the key epigenetic regulators of gene expression. They act through hybridization with their target mRNA and modulate the level of respective proteins via different mechanisms. Various cancer conditions are known to be associated with up- and downregulation of the oncogenic and tumor suppressor miRNAs, respectively. The levels of aberrantly expressed oncogenic miRNAs can be downregulated in different ways. Similarly, restoration of tumor suppressor miRNAs to their normal levels can be achieved using miRNA mimics. However, the use of miRNA mimics is limited by their reduced biostability and function. We have studied the hybridization thermodynamics of the miRNA 26a (11-mer, including the seed sequence) guide strand with the mRNA (11-mer) target strand in the absence and presence of AfPiwi protein. We have also inserted locked nucleic acids (LNAs) and 2'-O-methyl-modified nucleotides into the guide strand, in a walk-through manner, to assess their effect on the binding efficiency between guide and target RNA. Insertion of LNA and 2'-O-methyl-modified nucleotides into the guide strand helped to strengthen the binding affinity irrespective of the position of insertion. However, in the presence of AfPiwi protein, these modifications reduced the binding affinity to different extents depending on the position of insertion. Insertion of a modification leads to an increase in the enthalpic contribution with an increased unfavorable entropic contribution, which negatively compensates for the higher favorable enthalpy.
Aguado, Cristina; Gil, Maria-de-Los-Llanos; Yeste, Zaira; Giménez-Capitán, Ana; Teixidó, Cristina; Karachaliou, Niki; Viteri, Santiago; Rosell, Rafael; Molina-Vila, Miguel A
2018-01-01
Fusion of the anaplastic lymphoma receptor tyrosine kinase gene ( ALK ) with the echinoderm microtubule-associated protein 4 gene ( EML4 ) is the second most common actionable alteration in non-small-cell lung cancer, with a frequency of 5%. Here, we present a case of an EML4-ALK-positive patient with an atypical in-frame insertion from the LTBP1 gene in the canonical junction of variant 1 . The patient was a 39-year-old never-smoker female diagnosed with Stage IV lung adenocarcinoma. A core biopsy was negative for EGFR and KRAS mutations but positive for ALK immunohistochemistry and fluorescence in situ hybridization. When submitted to nCounter, the sample showed a 3'/5' imbalance indicative of an ALK rearrangement, but failed to give a positive signal for any of the variants tested. Finally, a band with a molecular weight higher than expected appeared after reverse transcriptase-polymerase chain reaction analysis. When Sanger sequencing was performed, the band revealed an atypical EML4-ALK fusion gene with an in-frame 129 bp insertion. A 115 bp segment of the insertion corresponded to an intronic region of LTBP1 , a gene located in the short arm of chromosome 2, between ALK and EML4 . The patient received crizotinib and showed a good therapeutic response that is still ongoing after 12 months. Our result suggests that short in-frame insertions of other genes in the EML4-ALK junction do not affect the sensitivity of the EML4-ALK fusion protein to crizotinib.
Chintalapati, Manjusha; Dannemann, Michael; Prüfer, Kay
2017-08-04
Small insertions and deletions occur in humans at a lower rate compared to nucleotide changes, but evolve under more constraint than nucleotide changes. While the evolution of insertions and deletions have been investigated using ape outgroups, the now available genome of a Neandertal can shed light on the evolution of indels in more recent times. We used the Neandertal genome together with several primate outgroup genomes to differentiate between human insertion/deletion changes that likely occurred before the split from Neandertals and those that likely arose later. Changes that pre-date the split from Neandertals show a smaller proportion of deletions than those that occurred later. The presence of a Neandertal-shared allele in Europeans or Asians but the absence in Africans was used to detect putatively introgressed indels in Europeans and Asians. A larger proportion of these variants reside in intergenic regions compared to other modern human variants, and some variants are linked to SNPs that have been associated with traits in modern humans. Our results are in agreement with earlier results that suggested that deletions evolve under more constraint than insertions. When considering Neandertal introgressed variants, we find some evidence that negative selection affected these variants more than other variants segregating in modern humans. Among introgressed variants we also identify indels that may influence the phenotype of their carriers. In particular an introgressed deletion associated with a decrease in the time to menarche may constitute an example of a former Neandertal-specific trait contributing to modern human phenotypic diversity.
Romo, Tod D; Bradney, Laura A; Greathouse, Denise V; Grossfield, Alan
2011-08-01
One approach to the growing health problem of antibiotic resistant bacteria is the development of antimicrobial peptides (AMPs) as alternative treatments. The mechanism by which these AMPs selectively attack the bacterial membrane is not well understood, but is believed to depend on differences in membrane lipid composition. N-acylation of the small amidated hexapeptide, RRWQWR-NH(2) (LfB6), derived from the 25 amino acid bovine lactoferricin (LfB25) can be an effective means to improve its antimicrobial properties. Here, we investigate the interactions of C6-LfB6, N-acylated with a 6 carbon fatty acid, with model lipid bilayers with two distinct compositions: 3:1 POPE:POPG (negatively charged) and POPC (zwitterionic). Results from solid-state (2)H and (31)P NMR experiments are compared with those from an ensemble of all-atom molecular dynamic simulations running in aggregate more than 8.6ms. (2)H NMR spectra reveal no change in the lipid acyl chain order when C6-LfB6 is bound to the negatively charged membrane and only a slight decrease in order when it is bound to the zwitterionic membrane. (31)P NMR spectra show no significant perturbation of the phosphate head groups of either lipid system in the presence of C6-LfB6. Molecular dynamic simulations show that for the negatively charged membrane, the peptide's arginines drive the initial association with the membrane, followed by attachment of the tryptophans at the membrane-water interface, and finally by the insertion of the C6 tails deep into the bilayer. In contrast, the C6 tail leads the association with the zwitterionic membrane, with the tryptophans and arginines associating with the membrane-water interface in roughly the same amount of time. We find similar patterns in the order parameters from our simulations. Moreover, we find in the simulations that the C6 tail can insert 1-2Å more deeply into the zwitterionic membrane and can exist in a wider range of angles than in the negatively charged membrane. We propose this is due to the larger area per lipid in the zwitterionic membrane, which provides more space for the C6 to insert and assume different orientations. Copyright © 2011 Elsevier B.V. All rights reserved.
Ultrasound-guided three-dimensional needle steering in biological tissue with curved surfaces
Abayazid, Momen; Moreira, Pedro; Shahriari, Navid; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak
2015-01-01
In this paper, we present a system capable of automatically steering a bevel-tipped flexible needle under ultrasound guidance toward a physical target while avoiding a physical obstacle embedded in gelatin phantoms and biological tissue with curved surfaces. An ultrasound pre-operative scan is performed for three-dimensional (3D) target localization and shape reconstruction. A controller based on implicit force control is developed to align the transducer with curved surfaces to assure the maximum contact area, and thus obtain an image of sufficient quality. We experimentally investigate the effect of needle insertion system parameters such as insertion speed, needle diameter and bevel angle on target motion to adjust the parameters that minimize the target motion during insertion. A fast sampling-based path planner is used to compute and periodically update a feasible path to the target that avoids obstacles. We present experimental results for target reconstruction and needle insertion procedures in gelatin-based phantoms and biological tissue. Mean targeting errors of 1.46 ± 0.37 mm, 1.29 ± 0.29 mm and 1.82 ± 0.58 mm are obtained for phantoms with inclined, curved and combined (inclined and curved) surfaces, respectively, for insertion distance of 86–103 mm. The achieved targeting errors suggest that our approach is sufficient for targeting lesions of 3 mm radius that can be detected using clinical ultrasound imaging systems. PMID:25455165
Pelet, T; Curran, J; Kolakofsky, D
1991-01-01
The P gene of bovine parainfluenza virus 3 (bPIV3) contains two downstream overlapping ORFs, called V and D. By comparison with the mRNA editing sites of other paramyxoviruses, two editing sites were predicted for bPIV3; site a to express the D protein, and site b to express the V protein. Examination of the bPIV3 mRNAs, however, indicates that site b is non-functional whereas site a operates frequently. Insertions at site a give rise to both V and D protein mRNAs, because a very broad distribution of Gs is added when insertions occur. This broad distribution is very different from the editing sites of Sendai virus or SV5, where predominantly one form of edited mRNA containing either a one or two G insertion respectively is created, to access the single overlapping ORF of these viruses. A model is proposed to explain how paramyxoviruses control the range of G insertions on that fraction of the mRNAs where insertions occur. The bPIV3 P gene is unique as far as we know, in that a sizeable portion of the gene expresses all 3 reading frames as protein. bPIV3 apparently does this from a single editing site by removing the constraints which control the number of slippage rounds which take place. Images PMID:1846805
Macdonald, N; Sullivan, A K; French, P; White, J A; Dean, G; Smith, A; Winter, A J; Alexander, S; Ison, C; Ward, H
2014-06-01
To identify risk factors for rectal lymphogranuloma venereum (rLGV) in men who have sex with men (MSM). A case-control study at 6 U.K. hospitals compared MSM with rLGV (cases) with rLGV-negative controls: MSM without potential rLGV symptoms (CGa) and separately, MSM with such symptoms (CGs). Between 2008 and 2010, there were 90 rLGV cases, 74 CGa and 69 CGs recruited. Lifestyles and sexual behaviours in the previous 3 months were reported using internet-based computer-assisted self-interviews. Logistic regression was used to investigate factors associated with rLGV. Cases were significantly more likely to be HIV-positive (89%) compared with CGa (46%) and CGs (64%). Independent behavioural risks for rLGV were: unprotected receptive anal intercourse (adjusted OR (AOR)10.7, 95% CI 3.5 to 32.8), fisting another (AOR=6.7, CI 1.8 to 25.3), sex under the influence of gamma-hydroxybutyrate (AOR=3.1, CI 1.3 to 7.4) and anonymous sexual contacts (AOR=2.7, CI 1.2 to 6.3), compared with CGa; unprotected insertive anal intercourse (AOR=4.7, CI 2.0 to 10.9) and rectal douching (AOR=2.9 CI 1.3 to 6.6), compared with CGs. An incubation period from exposure to symptoms of 30 days was indicated. Unprotected receptive anal intercourse is a key risk factor for rectal LGV with the likelihood that rectal-to-rectal transmission is facilitated where insertive anal sex also occurs. The association between HIV and rLGV appears linked to HIV-positive men seeking unprotected sex with others with the same HIV status, sexual and drug interests. Such men should be targeted for frequent STI screening and interventions to minimise associated risks. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Macdonald, N; Sullivan, A K; French, P; White, J A; Dean, G; Smith, A; Winter, A J; Alexander, S; Ison, C; Ward, H
2014-01-01
Objective To identify risk factors for rectal lymphogranuloma venereum (rLGV) in men who have sex with men (MSM). Design A case-control study at 6 UK hospitals compared MSM with rLGV (cases) with rLGV-negative controls: MSM without potential rLGV symptoms (CGa) and separately, MSM with such symptoms (CGs). Methods Between 2008 and 2010, there were 90 rLGV cases, 74 CGa and 69 CGs recruited. Lifestyles and sexual behaviours in the previous 3 months were reported using internet-based computer-assisted self-interviews. Logistic regression was used to investigate factors associated with rLGV. Results Cases were significantly more likely to be HIV-positive (89%) compared with CGa (46%) and CGs (64%). Independent behavioural risks for rLGV were: unprotected receptive anal intercourse (adjusted OR (AOR)10.7, 95% CI 3.5 to 32.8), fisting another (AOR=6.7, CI 1.8 to 25.3), sex under the influence of gamma-hydroxybutyrate (AOR=3.1, CI 1.3 to 7.4) and anonymous sexual contacts (AOR=2.7, CI 1.2 to 6.3), compared with CGa; unprotected insertive anal intercourse (AOR=4.7, CI 2.0 to 10.9) and rectal douching (AOR=2.9 CI 1.3 to 6.6), compared with CGs. An incubation period from exposure to symptoms of 30 days was indicated. Conclusions Unprotected receptive anal intercourse is a key risk factor for rectal LGV with the likelihood that rectal-to-rectal transmission is facilitated where insertive anal sex also occurs. The association between HIV and rLGV appears linked to HIV-positive men seeking unprotected sex with others with the same HIV status, sexual and drug interests. Such men should be targeted for frequent STI screening and interventions to minimise associated risks. PMID:24493859
van Mourik, Maaike S M; Groenwold, Rolf H H; Berkelbach van der Sprenkel, Jan Willem; van Solinge, Wouter W; Troelstra, Annet; Bonten, Marc J M
2011-01-01
Monitoring of healthcare-associated infection rates is important for infection control and hospital benchmarking. However, manual surveillance is time-consuming and susceptible to error. The aim was, therefore, to develop a prediction model to retrospectively detect drain-related meningitis (DRM), a frequently occurring nosocomial infection, using routinely collected data from a clinical data warehouse. As part of the hospital infection control program, all patients receiving an external ventricular (EVD) or lumbar drain (ELD) (2004 to 2009; n = 742) had been evaluated for the development of DRM through chart review and standardized diagnostic criteria by infection control staff; this was the reference standard. Children, patients dying <24 hours after drain insertion or with <1 day follow-up and patients with infection at the time of insertion or multiple simultaneous drains were excluded. Logistic regression was used to develop a model predicting the occurrence of DRM. Missing data were imputed using multiple imputation. Bootstrapping was applied to increase generalizability. 537 patients remained after application of exclusion criteria, of which 82 developed DRM (13.5/1000 days at risk). The automated model to detect DRM included the number of drains placed, drain type, blood leukocyte count, C-reactive protein, cerebrospinal fluid leukocyte count and culture result, number of antibiotics started during admission, and empiric antibiotic therapy. Discriminatory power of this model was excellent (area under the ROC curve 0.97). The model achieved 98.8% sensitivity (95% CI 88.0% to 99.9%) and specificity of 87.9% (84.6% to 90.8%). Positive and negative predictive values were 56.9% (50.8% to 67.9%) and 99.9% (98.6% to 99.9%), respectively. Predicted yearly infection rates concurred with observed infection rates. A prediction model based on multi-source data stored in a clinical data warehouse could accurately quantify rates of DRM. Automated detection using this statistical approach is feasible and could be applied to other nosocomial infections.
Direct laser written polymer waveguides with out of plane couplers for optical chips
NASA Astrophysics Data System (ADS)
Landowski, Alexander; Zepp, Dominik; Wingerter, Sebastian; von Freymann, Georg; Widera, Artur
2017-10-01
Optical technologies call for waveguide networks featuring high integration densities, low losses, and simple operation. Here, we present polymer waveguides fabricated from a negative tone photoresist via two-photon-lithography in direct laser writing, and show a detailed parameter study of their performance. Specifically, we produce waveguides featuring bend radii down to 40 μ m, insertion losses of the order of 10 dB, and loss coefficients smaller than 0.81 dB mm-1, facilitating high integration densities in writing fields of 300 μ m×300 μ m. A novel three-dimensional coupler design allows for coupling control as well as direct observation of outputs in a single field of view through a microscope objective. Finally, we present beam-splitting devices to construct larger optical networks, and we show that the waveguide material is compatible with the integration of quantum emitters.
Non-reciprocal optical mirrors based on spatio-temporal acousto-optic modulation
NASA Astrophysics Data System (ADS)
Fleury, R.; Sounas, D. L.; Alù, A.
2018-03-01
Here, we investigate a scheme to realize free-space isolators and highly non-reciprocal mirrors with weak modulation imparted by an acoustic wave. We propose a strategy to dramatically break time-reversal symmetry by exploiting resonant interactions between a travelling acoustic wave and highly resonant Fabry-Pérot modes, inducing total reflection of an optical beam at a given angle, and no reflection at the negative angle. Different from conventional acousto-optic isolators, which are based on non-resonant frequency conversion and filtering, our proposal operates at the frequency of the optical signal by tailoring the resonant properties of the structure as well as the acoustic wave frequency and intensity, enabling 50 dB isolation with modest modulation requirements. Operation in the reflection mode allows for close-to-zero insertion loss, enabling disruptive opportunities in our ability to control and manipulate photons.
System design of ELITE power processing unit
NASA Astrophysics Data System (ADS)
Caldwell, David J.
The Electric Propulsion Insertion Transfer Experiment (ELITE) is a space mission planned for the mid 1990s in which technological readiness will be demonstrated for electric orbit transfer vehicles (EOTVs). A system-level design of the power processing unit (PPU), which conditions solar array power for the arcjet thruster, was performed to optimize performance with respect to reliability, power output, efficiency, specific mass, and radiation hardness. The PPU system consists of multiphased parallel switchmode converters, configured as current sources, connected directly from the array to the thruster. The PPU control system includes a solar array peak power tracker (PPT) to maximize the power delivered to the thruster regardless of variations in array characteristics. A stability analysis has been performed to verify that the system is stable despite the nonlinear negative impedance of the PPU input and the arcjet thruster. Performance specifications are given to provide the required spacecraft capability with existing technology.
Electrolytic echo enhancement: a novel method to make needles more reflective to ultrasound.
Cockburn, John F; Khosh, Stefan K
2014-04-01
This study examines the effect of augmenting the ultrasound reflectivity of needles using a novel electrolytic echo enhancement method. Needles were connected by a lead to the negative terminal of a 4.5 V direct current source. A grounding pad, connected to the positive terminal, was positioned on the undersurface of an ex vivo ox liver phantom. During needle insertion into the liver, electrolysis was induced creating a layer of gas on the needle electrode. Analysis of images showed a significant increase in needle brightness using electrolytic echo enhancement. Brightness was found to increase by a factor of ×3.6 compared with controls (P < 0.001). Electrolytic echo enhancement has the potential to make ultrasound-guided procedures safer and quicker for patients and increase the confidence of operators in their ability to see the whole needle including its tip. © 2014 The Royal Australian and New Zealand College of Radiologists.
NASA Astrophysics Data System (ADS)
Purewal, Justin; Wang, John; Graetz, Jason; Soukiazian, Souren; Tataria, Harshad; Verbrugge, Mark W.
2014-12-01
Capacity fade is reported for 1.5 Ah Li-ion batteries containing a mixture of Li-Ni-Co-Mn oxide (NCM) + Li-Mn oxide spinel (LMO) as positive electrode material and a graphite negative electrode. The batteries were cycled at a wide range of temperatures (10 °C-46 °C) and discharge currents (0.5C-6.5C). The measured capacity losses were fit to a simple physics-based model which calculates lithium inventory loss from two related mechanisms: (1) mechanical degradation at the graphite anode particle surface caused by diffusion-induced stresses (DIS) and (2) chemical degradation caused by lithium loss to continued growth of the solid-electrolyte interphase (SEI). These two mechanisms are coupled because lithium is consumed through SEI formation on newly exposed crack surfaces. The growth of crack surface area is modeled as a fatigue phenomenon due to the cyclic stresses generated by repeated lithium insertion and de-insertion of graphite particles. This coupled chemical-mechanical degradation model is consistent with the observed capacity loss features for the NCM + LMO/graphite cells.
Clinical effectiveness of lidocaine and benzocaine for topical anesthesia.
Rosa, A. L.; Sverzut, C. E.; Xavier, S. P.; Lavrador, M. A.
1999-01-01
The effectiveness of lidocaine and benzocaine in reducing pain produced by needle insertion into the palate was evaluated in a double-blind and placebo-controlled study using a more suitable method. Twenty subjects, 10 men and 10 women, submitted to 4 sessions in which they were randomly treated with 5% lidocaine, a placebo that tasted like lidocaine, 20% benzocaine, and a placebo that tasted like benzocaine. At each session, a 27-gauge needle was inserted into the palate twice, once before (baseline) and once after drug application for 1 minute. Immediately after each insertion, subjects indicated on a visual analog scale the pain intensity perceived. Lidocaine and benzocaine were equally efficient, and both were better than placebo in reducing pain caused by insertion of needles into the palate. PMID:11692349
Effects of the HEET garment in the prevention of hypothermia in a porcine model.
Johnson, Don; Gegel, Brian; Burgert, James; Duncklee, Geoffrey W; Robison, Ricci R; Lewis, Eric J; Crum, Paul M; Kuhns, William; Moore, Daniel; O'Brien, Scott; Elliott, Joel; Washington, Jason; Boyle, John; Seigler, Dale
2010-11-01
Hypothermia is a common battlefield trauma occurrence. This study compared the effectiveness of the hypothermia, environmental, exposure, and trauma (HEET) garment (Trident Industries, Beaufort, SC) with and without thermal inserts with a control group of two wool blankets in the prevention of hypothermia in a treated hypovolemic porcine model. Five female swine (Sus scrofa-Yorkshire cross) were assigned to each of three groups: HEET with thermal inserts (n=5); HEET without thermal inserts (n=5); or control (n=5). After the animals were anesthetized and stabilized for 30 min, the swine were hemorrhaged to a mean arterial pressure (MAP) of 30 mm Hg, simulating a battlefield injury. Hetastarch 6% (500 mL) was rapidly administered, simulating initial field resuscitation. One hour later, the animals' shed blood was reinfused, simulating transfusion at a field medical facility. The investigators moved the animal into a cooler set at 10°C ± 0.5°C. A pulmonary artery catheter was used to monitor core body temperature over a 6-h period. A repeated measures ANOVA and Tukey's post hoc test were used to analyze the data. There was a significant difference between the groups. At the end of 6h, the mean core temperature for the HEET with inserts group was 32.69°C ± 1.5; the HEET without inserts, 31.02°C ± 1.8; and control, 34.78°C ± 1.2 (P<0.05). While all groups became hypothermic, the wool blanket group was most effective in maintaining body temperature closer to normothermia. The HEET garments with and without heaters are ineffective in preventing hypothermia. Copyright © 2010 Elsevier Inc. All rights reserved.
Zhu, Yue-Qi; Yang, Kai; Edmonds, Laura; Wei, Li-Ming; Zheng, Reila; Cheng, Ruo-Yu; Cui, Wen-Guo; Cheng, Ying-Sheng
2017-01-01
We determined the feasibility of, and tissue response to silicone-covered biodegradable magnesium- and plastic-stent insertion into the esophagus in rabbits. The mechanical compression-recovery characteristics and degradation behaviors of the magnesium stent were investigated in vitro . A total of 45 rabbits were randomly divided into a magnesium- ( n = 15) and a plastic- ( n = 15) stent group, and underwent stent insertion into the lower third of the esophagus under fluoroscopic guidance; a control group ( n = 15) did not undergo the intervention. Esophagography was performed at 1, 2, and 4 weeks. Five rabbits in each group were euthanized at each time point for histological examination. Silicone-covered magnesium stents showed similar radial force to plastic stents ( p > 0.05). The magnesium stents degraded rapidly in an acidic solution, but 90.2% ± 3.1% of the residual mass was maintained after a 2-week degradation in a solution with a pH of 4.0. All stent insertions were well tolerated. Magnesium stents migrated in six rabbits (one at 1 week, one at 2 weeks and four at 4 weeks), and plastic stents migrated in three rabbits (one at 2 weeks and two at 4 weeks; p > 0.05). Esophageal wall remodeling (thinner epithelial and smooth muscle layers) was similar in both stented groups ( p > 0.05), and the esophagus wall was found to be significantly thinner in the stented groups than in the control group ( p < 0.05). Esophageal injury and collagen deposition following stent insertion were similar and did not differ from the control group ( p > 0.05). Esophageal silicone-covered magnesium stents provided reliable support for at least 2 weeks, with acceptable migration rates and without causing severe injury or tissue reaction compared with plastic stents.
Zhu, Yue-Qi; Yang, Kai; Edmonds, Laura; Wei, Li-Ming; Zheng, Reila; Cheng, Ruo-Yu; Cui, Wen-Guo; Cheng, Ying-Sheng
2016-01-01
Background: We determined the feasibility of, and tissue response to silicone-covered biodegradable magnesium- and plastic-stent insertion into the esophagus in rabbits. Methods: The mechanical compression–recovery characteristics and degradation behaviors of the magnesium stent were investigated in vitro. A total of 45 rabbits were randomly divided into a magnesium- (n = 15) and a plastic- (n = 15) stent group, and underwent stent insertion into the lower third of the esophagus under fluoroscopic guidance; a control group (n = 15) did not undergo the intervention. Esophagography was performed at 1, 2, and 4 weeks. Five rabbits in each group were euthanized at each time point for histological examination. Results: Silicone-covered magnesium stents showed similar radial force to plastic stents (p > 0.05). The magnesium stents degraded rapidly in an acidic solution, but 90.2% ± 3.1% of the residual mass was maintained after a 2-week degradation in a solution with a pH of 4.0. All stent insertions were well tolerated. Magnesium stents migrated in six rabbits (one at 1 week, one at 2 weeks and four at 4 weeks), and plastic stents migrated in three rabbits (one at 2 weeks and two at 4 weeks; p > 0.05). Esophageal wall remodeling (thinner epithelial and smooth muscle layers) was similar in both stented groups (p > 0.05), and the esophagus wall was found to be significantly thinner in the stented groups than in the control group (p < 0.05). Esophageal injury and collagen deposition following stent insertion were similar and did not differ from the control group (p > 0.05). Conclusions: Esophageal silicone-covered magnesium stents provided reliable support for at least 2 weeks, with acceptable migration rates and without causing severe injury or tissue reaction compared with plastic stents. PMID:28286555
Ultrasonic airborne insertion loss measurements at normal incidence (L).
Farley, Jayrin; Anderson, Brian E
2010-12-01
Transmission loss and insertion loss measurements of building materials at audible frequencies are commonly made using plane wave tubes or as a panel between reverberant rooms. These measurements provide information for noise isolation control in architectural acoustics and in product development. Airborne ultrasonic sound transmission through common building materials has not been fully explored. Technologies and products that utilize ultrasonic frequencies are becoming increasingly more common, hence the need to conduct such measurements. This letter presents preliminary measurements of the ultrasonic insertion loss levels for common building materials over a frequency range of 28-90 kHz using continuous-wave excitation.
Yoo, Tae Keun; Han, Sueng-Han; Han, Jinu
2017-12-01
To determine the efficacy of a biodegradable Ologen (Aeon Astron Europe BV, Leiden, The Netherlands) collagen matrix in reducing the blue color change due to exposed thinned sclera after strabismus surgery. Fourteen patients with intermittent exotropia undergoing symmetric bilateral lateral rectus recession surgery were included in this prospective, randomized, paired-eye controlled study. In each patient, Ologen was implanted at the original rectus insertion site in one randomly selected eye; the other eye underwent conventional surgery. Ologen was inserted under the conjunctiva without suturing, covering the muscle insertion site. Conjunctival color change was analyzed using computer-based image analysis immediately and 1 week, 1 month, and 3 months postoperatively. Slit-lamp photographs of each eye were evaluated using contrast limited adaptive histogram equalization (CLAHE), Canny edge, and the RGB (red-green-blue) model. Secondary outcomes were conjunctival and sclera thickness 3 months postoperatively determined by anterior segment optical coherence tomography. Immediately and 1 week postoperatively all color models showed no significant differences between Ologen-implanted and control eyes. Three months postoperatively, Ologen-implanted eyes exhibited significantly lower CLAHE (P = 0.041) and RGB model blue color (P = 0.008) values than control eyes. Canny edge (P = 0.061) and RGB model red color (P = 0.152) values did not differ between eyes. Conjunctival stroma and episcleral complex thickness was greater in Ologen-implanted eyes than in controls (P = 0.001). Blue color change was significantly less noticeable in Ologen-implanted eyes than in controls. Thus, Ologen implantation helps prevent visible blue sclera at the original rectus insertion site after lateral rectus recession. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.
Shahriari, Navid; Hekman, Edsko; Oudkerk, Matthijs; Misra, Sarthak
2015-11-01
Percutaneous needle insertion procedures are commonly used for diagnostic and therapeutic purposes. Although current technology allows accurate localization of lesions, they cannot yet be precisely targeted. Lung cancer is the most common cause of cancer-related death, and early detection reduces the mortality rate. Therefore, suspicious lesions are tested for diagnosis by performing needle biopsy. In this paper, we have presented a novel computed tomography (CT)-compatible needle insertion device (NID). The NID is used to steer a flexible needle (φ0.55 mm) with a bevel at the tip in biological tissue. CT images and an electromagnetic (EM) tracking system are used in two separate scenarios to track the needle tip in three-dimensional space during the procedure. Our system uses a control algorithm to steer the needle through a combination of insertion and minimal number of rotations. Noise analysis of CT images has demonstrated the compatibility of the device. The results for three experimental cases (case 1: open-loop control, case 2: closed-loop control using EM tracking system and case 3: closed-loop control using CT images) are presented. Each experimental case is performed five times, and average targeting errors are 2.86 ± 1.14, 1.11 ± 0.14 and 1.94 ± 0.63 mm for case 1, case 2 and case 3, respectively. The achieved results show that our device is CT-compatible and it is able to steer a bevel-tipped needle toward a target. We are able to use intermittent CT images and EM tracking data to control the needle path in a closed-loop manner. These results are promising and suggest that it is possible to accurately target the lesions in real clinical procedures in the future.
Meirik, Olav; Brache, Vivian; Orawan, Kiriwat; Habib, Ndema Abu; Schmidt, Johannes; Ortayli, Nuriye; Culwell, Kelly; Jackson, Emily; Ali, Moazzam
2013-01-01
Comparative data on etonogestrel and two-rod levonorgestrel contraceptive implants are lacking. A multicenter, open, parallel-group trial with random allocation of implants was performed. For every second implant user, an age-matched woman choosing an intrauterine device (IUD) (TCu380A) was admitted. Methods and data on implant/IUD insertion and 6-week follow-up are reported. A total of 2008 women were randomized to an implant, and 974 women were enrolled in the IUD group. Results from 997 etonogestrel implant users, 997 levonorgestrel implant users and 971 IUD users were analyzed. In the etonogestrel and levonorgestrel groups, respectively, mean insertion durations were 51 (SD 50.2) s and 88 (SD 60.8) s; complication rates at insertion were 0.8% and 0.2%; and at follow-up, 27.2% and 26.7% of women, respectively, had signs or symptoms at the insertion site. At follow-up within 6 weeks after insertion, all implants were in situ, while 2.1% of IUDs were expelled. Performance of etonogestrel and levonorgestrel implants at insertion and within the first 6 weeks is similar. Short-term (6 weeks) continuation rates appear higher for implants than TCu380A. Copyright © 2013 Elsevier Inc. All rights reserved.
Serrano, Priscila de Oliveira; Faot, Fernanda; Del Bel Cury, Altair Antoninha; Rodrigues Garcia, Renata Cunha Matheus
2008-01-01
This study described changes in mandibular movements during pronunciation of /m/ and /s/ sounds in Portuguese, in patients presenting dental wear before and after appliance insertion and tooth reconstruction. Subjects were divided into a control group of dentate patients and an experimental group of patients with incisal tooth wear due to bruxism. A magnetic jaw tracking device measured the jaw opening, and translations to left and right sides of the mandible during pronunciation of phonemes. Evaluations were carried out 1 week and immediately before appliance insertion; 24 h, 7, 30 and 60 days after appliance insertion; and 1 week and 1 month after tooth reconstruction. Data were submitted to two-way ANOVA, Mann-Whitney and Friedman tests (p<0.05). Jaw opening was different (p<0.05) for both sounds in all periods. The anteroposterior amplitude for /s/ showed differences immediately before and 1 month after appliance insertion (p<0.05). Lateral amplitude for the right side showed differences between groups after appliance insertion for /s/, and 1 and 2 months after appliance insertion for the /m/ (p<0.05). Volunteers with anterior tooth wear had a wider opening movement, and the movements during speech of /m/ and /s/ sounds were not changed after appliance insertion and reconstruction of teeth.
Analytic Steering: Inserting Context into the Information Dialog
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bohn, Shawn J.; Calapristi, Augustin J.; Brown, Shyretha D.
2011-10-23
An analyst’s intrinsic domain knowledge is a primary asset in almost any analysis task. Unstructured text analysis systems that apply un-supervised content analysis approaches can be more effective if they can leverage this domain knowledge in a manner that augments the information discovery process without obfuscating new or unexpected content. Current unsupervised approaches rely upon the prowess of the analyst to submit the right queries or observe generalized document and term relationships from ranked or visual results. We propose a new approach which allows the user to control or steer the analytic view within the unsupervised space. This process ismore » controlled through the data characterization process via user supplied context in the form of a collection of key terms. We show that steering with an appropriate choice of key terms can provide better relevance to the analytic domain and still enable the analyst to uncover un-expected relationships; this paper discusses cases where various analytic steering approaches can provide enhanced analysis results and cases where analytic steering can have a negative impact on the analysis process.« less
Nonreciprocal Gain in Non-Hermitian Time-Floquet Systems
NASA Astrophysics Data System (ADS)
Koutserimpas, Theodoros T.; Fleury, Romain
2018-02-01
We explore the unconventional wave scattering properties of non-Hermitian systems in which amplification or damping are induced by time-periodic modulation. These non-Hermitian time-Floquet systems are capable of nonreciprocal operations in the frequency domain, which can be exploited to induce novel physical phenomena such as unidirectional wave amplification and perfect nonreciprocal response with zero or even negative insertion losses. This unique behavior is obtained by imparting a specific low-frequency time-periodic modulation to the complex coupling between lossless resonators, promoting only upward frequency conversion, and leading to nonreciprocal parametric gain. We provide a full-wave demonstration of our findings in a one-way microwave amplifier, and establish the potential of non-Hermitian time-Floquet devices for insertion-loss free microwave isolation and unidirectional parametric amplification.
Effect of Off-Axis Screw Insertion, Insertion Torque, and Plate Contouring on Locked Screw Strength
Gallagher, Bethany; Silva, Matthew J.; Ricci, William M.
2015-01-01
Objectives This study quantifies the effects of insertion torque, off-axis screw angulation, and plate contouring on the strength of locking plate constructs. Methods Groups of locking screws (n = 6–11 screws) were inserted at 50%, 100%, 150%, and 200% of the manufacturer-recommended torque (3.2 Nm) into locking compression plates at various angles: orthogonal (control), 5-degree angle off-axis, and 10-degree angle off-axis. Screws were loaded to failure by a transverse force (parallel to the plate) either in the same (“+”) or opposite direction (“−”) of the initial screw angulation. Separately, locking plates were bent to 5 and 10-degree angles, with the bend apex at a screw hole. Locking screws inserted orthogonally into the apex hole at 100% torque were loaded to failure. Results Orthogonal insertion resulted in the highest average load to failure, 2577 ± 141 N (range, 2413–2778 N), whereas any off-axis insertion significantly weakened constructs (165–1285 N, at 100% torque) (P < 0.05). For “+” loading, torque beyond 100% did not increase strength, but 50% torque reduced screw strength (P < 0.05). Loading in the “−” direction consistently resulted in higher strengths than “+” loading (P < 0.05). Plate contouring of 5-degree angle did not significantly change screw strength compared with straight plates but contouring of 10-degree angle significantly reduced load to failure (P < 0.05). Conclusions To maximize the screw plate interface strength, locking screws should be inserted without cross-threading. The mechanical stability of locked screws is significantly compromised by loose insertion, off-axis insertion, or severe distortion of the locking mechanism. PMID:24343255
Immunization of black-tailed prairie dog against plague through consumption of vaccine-laden baits
Rocke, Tonie E.; Smith, Susan; Stinchcomb, D.T.; Osorio, Jorge E.
2008-01-01
Prairie dogs (Cynomys spp.) are highly susceptible to Yersinia pestis and, along with other wild rodents, are significant reservoirs of plague for other wildlife and humans in the western United States. A recombinant raccoon poxvirus, expressing the F1 antigen of Y. pestis, was incorporated into a palatable bait and offered to three groups (n=18, 19, and 20) of black-tailed prairie dogs (Cynomys ludovicianus) for voluntary consumption, either one, two, or three times, at roughly 3-wk intervals. A control group (n=19) received baits containing raccoon poxvirus without the inserted antigen. Mean antibody titers to Y. pestis F1 antigen increased significantly in all groups ingesting the vaccine-laden baits, whereas the control group remained negative. Upon challenge with virulent Y. pestis, immunized groups had higher survival rates (38%) than the unimmunized control group (11%). The mean survival time of groups ingesting vaccine-laden baits either two or three times was significantly higher than that of animals ingesting vaccine-laden baits just one time and of animals in the control group. These results show that oral immunization of prairie dogs against plague provides some protection against challenge at dosages that simulate simultaneous delivery of the plague bacterium by numerous (3–10) flea bites.
Immunization of black-tailed prairie dog against plague through consumption of vaccine-laden baits.
Rocke, Tonie E; Smith, Susan R; Stinchcomb, Dan T; Osorio, Jorge E
2008-10-01
Prairie dogs (Cynomys spp.) are highly susceptible to Yersinia pestis and, along with other wild rodents, are significant reservoirs of plague for other wildlife and humans in the western United States. A recombinant raccoon poxvirus, expressing the F1 antigen of Y. pestis, was incorporated into a palatable bait and offered to three groups (n = 18, 19, and 20) of black-tailed prairie dogs (Cynomys ludovicianus) for voluntary consumption, either one, two, or three times, at roughly 3-wk intervals. A control group (n = 19) received baits containing raccoon poxvirus without the inserted antigen. Mean antibody titers to Y. pestis F1 antigen increased significantly in all groups ingesting the vaccine-laden baits, whereas the control group remained negative. Upon challenge with virulent Y. pestis, immunized groups had higher survival rates (38%) than the unimmunized control group (11%). The mean survival time of groups ingesting vaccine-laden baits either two or three times was significantly higher than that of animals ingesting vaccine-laden baits just one time and of animals in the control group. These results show that oral immunization of prairie dogs against plague provides some protection against challenge at dosages that simulate simultaneous delivery of the plague bacterium by numerous (3-10) flea bites.
Abdelsalam, Mohamed; Chen, Shih-Chu; Yoshida, Terutoyo
2010-08-01
The Lancefield group C alpha-hemolytic Streptococcus dysgalactiae ssp. dysgalactiae (GCSD) causes systemic granulomatous inflammatory disease and high mortality rates in infected fish. Superantigen and streptolysin S genes are the most important virulence factors contributing to an invasive streptococcal infection. PCR amplification revealed that all strains isolated from moribund fish harbored the streptolysin S structural gene (sagA). GCSD fish isolates were PCR negative for emm, speA, speB, speC, speM, smeZ, and ssa. However, the size of the streptococcal pyrogenic exotoxin G (spegg) locus, a superantigen, in positive S. dysgalactiae fish and pig strains was variable. The ORF of the spegg locus of 26 GCSD fish strains and one GCSD pig strain was inserted with IS981SC. Interestingly, the ORF of the spegg locus of two fish strains of GCSD collected in Malaysia was inserted with an IS981SC-IS1161 hybrid IS element. The hybrid IS element was found in all of the GCSD fish isolates and one GCSD pig through PCR screening. Although no insertion sequence (IS) was detected in the spegg locus of S. dysgalactiae ssp. equisimilis (GCSE) strains, a five-nucleotide deletion mutation was detected in the ORF of the spegg locus of one GCSE strain at the supposed site of IS981SC insertion, resulting in a frameshift mutation.
Venken, Koen J. T.; Schulze, Karen L.; Haelterman, Nele A.; Pan, Hongling; He, Yuchun; Evans-Holm, Martha; Carlson, Joseph W.; Levis, Robert W.; Spradling, Allan C.; Hoskins, Roger A.; Bellen, Hugo J.
2011-01-01
We demonstrate the versatility of a collection of insertions of the transposon Minos mediated integration cassette (MiMIC), in Drosophila melanogaster. MiMIC contains a gene-trap cassette and the yellow+ marker flanked by two inverted bacteriophage ΦC31 attP sites. MiMIC integrates almost at random in the genome to create sites for DNA manipulation. The attP sites allow the replacement of the intervening sequence of the transposon with any other sequence through recombinase mediated cassette exchange (RMCE). We can revert insertions that function as gene traps and cause mutant phenotypes to wild type by RMCE and modify insertions to control GAL4 or QF overexpression systems or perform lineage analysis using the Flp system. Insertions within coding introns can be exchanged with protein-tag cassettes to create fusion proteins to follow protein expression and perform biochemical experiments. The applications of MiMIC vastly extend the Drosophila melanogaster toolkit. PMID:21985007
The behavior of Metropolis-coupled Markov chains when sampling rugged phylogenetic distributions.
Brown, Jeremy M; Thomson, Robert C
2018-02-15
Bayesian phylogenetic inference involves sampling from posterior distributions of trees, which sometimes exhibit local optima, or peaks, separated by regions of low posterior density. Markov chain Monte Carlo (MCMC) algorithms are the most widely used numerical method for generating samples from these posterior distributions, but they are susceptible to entrapment on individual optima in rugged distributions when they are unable to easily cross through or jump across regions of low posterior density. Ruggedness of posterior distributions can result from a variety of factors, including unmodeled variation in evolutionary processes and unrecognized variation in the true topology across sites or genes. Ruggedness can also become exaggerated when constraints are placed on topologies that require the presence or absence of particular bipartitions (often referred to as positive or negative constraints, respectively). These types of constraints are frequently employed when conducting tests of topological hypotheses (Bergsten et al. 2013; Brown and Thomson 2017). Negative constraints can lead to particularly rugged distributions when the data strongly support a forbidden clade, because monophyly of the clade can be disrupted by inserting outgroup taxa in many different ways. However, topological moves between the alternative disruptions are very difficult, because they require swaps between the inserted outgroup taxa while the data constrain taxa from the forbidden clade to remain close together on the tree. While this precise form of ruggedness is particular to negative constraints, trees with high posterior density can be separated by similarly complicated topological rearrangements, even in the absence of constraints.
Cowett, Allison A; Ali, Rose; Cooper, Mary A; Evans, Mark; Conzuelo, Gabriel; Cremer, Miriam
2018-05-01
To compare the 6-month use rate of the etonogestrel implant placed immediately after dilation and evacuation (D&E) with placement 2-4 weeks postprocedure. This is a randomized controlled trial of women seeking abortion between 14 0/7 and 23 5/7 weeks of gestation and desiring the etonogestrel contraceptive implant at an urban family planning clinic. Participants were randomized to device insertion immediately after the D&E compared with delayed insertion in 2-4 weeks. The primary outcome was implant use rate at 6 months after insertion and was determined by follow-up phone interviews. Secondary outcomes included repeat pregnancy rates and method satisfaction. The sample size of 120 participants was calculated based on a power of 0.80 to demonstrate a 20% difference in implant use rates between groups assuming 40% of women overall are not using the device 6 months after the procedure. Between November 2015 and October 2016, 148 participants were enrolled. Seventy-three participants (49.3%) were randomized to and underwent immediate implant insertion after D&E. The remaining 75 (50.6%) were randomized to delayed insertion. There were no significant differences in sociodemographic characteristics between the groups. Placement rate was 100% in the immediate group compared with 42.7% in the delayed group (P<.01). At 6 months, 40 of 43 (93%) women from the immediate group who completed follow-up continued use of the implant, whereas 19 of 30 (63.3%) women from the delayed group who completed follow-up were using the device (P=.002). Follow-up rates were low at 58.9% in the immediate group compared with 40.0% in the delayed group. Women were more likely to be using the etonogestrel implant at 6 months after D&E if they underwent immediate compared with delayed insertion. The very high loss to follow-up rate makes it difficult to draw conclusions about acceptability of the device and pregnancy rates. ClinicalTrials.gov, 02037919.
Exploring the role of 3-dimensional simulation in surgical training: feedback from a pilot study.
Podolsky, Dale J; Martin, Allan R; Whyne, Cari M; Massicotte, Eric M; Hardisty, Michael R; Ginsberg, Howard J
2010-12-01
Randomized control study assessing the efficacy of a pedicle screw insertion simulator. To evaluate the efficacy of an in-house developed 3-dimensional software simulation tool for teaching pedicle screw insertion, to gather feedback about the utility of the simulator, and to help identify the context and role such simulation has in surgical education. Traditional instruction for pedicle screw insertion technique consists of didactic teaching and limited hands-on training on artificial or cadaveric models before guided supervision within the operating room. Three-dimensional computer simulation can provide a valuable tool for practicing challenging surgical procedures; however, its potential lies in its effective integration into student learning. Surgical residents were recruited from 2 sequential years of a spine surgery course. Patient and control groups both received standard training on pedicle screw insertion. The patient group received an additional 1-hour session of training on the simulator using a CT-based 3-dimensional model of their assigned cadaver's spine. Qualitative feedback about the simulator was gathered from the trainees, fellows, and staff surgeons, and all pedicles screws physically inserted into the cadavers during the courses were evaluated through CT. A total of 185 thoracic and lumbar pedicle screws were inserted by 37 trainees. Eighty-two percent of the 28 trainees who responded to the questionnaire and all fellows and staff surgeons felt the simulator to be a beneficial educational tool. However, the 1-hour training session did not yield improved performance in screw placement. A 3-dimensional computer-based simulation for pedicle screw insertion was integrated into a cadaveric spine surgery instructional course. Overall, the tool was positively regarded by the trainees, fellows, and staff surgeons. However, the limited training with the simulator did not translate into widespread comfort with its operation or into improvement in physical screw placement.
Marnejon, Thomas; Angelo, Debra; Abu Abdou, Ahmed; Gemmel, David
2012-01-01
To identify clinically important risk factors associated with upper extremity venous thrombosis following peripherally inserted central venous catheters (PICC). A retrospective case control study of 400 consecutive patients with and without upper extremity venous thrombosis post-PICC insertion was performed. Patient data included demographics, body mass index (BMI), ethnicity, site of insertion, size and lumen of catheter, internal length, infusate, and co-morbidities, such as diabetes mellitus, congestive heart failure, and renal failure. Additional risk factors analyzed were active cancer, any history of cancer, recent trauma, smoking, a history of prior deep vein thrombosis, and recent surgery, defined as surgery within three months prior to PICC insertion. The prevalence of trauma, renal failure, and infusion with antibiotics and total parenteral nutrition (TPN) was higher among patients exhibiting upper extremity venous thrombosis (UEVT), when compared to controls. Patients developing UEVT were also more likely to have PICC line placement in a basilic vein and less likely to have brachial vein placement (P<.001). Left-sided PICC line sites also posed a greater risk (P=.026). The rate of standard DVT prophylaxis with low molecular weight heparin and unfractionated heparin and the use of warfarin was similar in both groups. Average length of hospital stay was almost double among patients developing UEVT, 19.5 days, when compared to patients undergoing PICC line insertion without thrombosis, 10.8 days (t=6.98, P<.001). In multivariate analysis, trauma, renal failure, left-sided catheters, basilic placement, TPN, and infusion with antibiotics, specifically vancomycin, were significant risk factors for UEVT associated with PICC insertion. Prophylaxis with low molecular weight heparin, unfractionated heparin or use of warfarin did not prevent the development of venous thrombosis in patients with PICCs. Length of hospital stay and cost are markedly increased in patients who develop PICC-associated upper extremity venous thrombosis.
ERIC Educational Resources Information Center
Reynolds, Ralph E.; And Others
Forty-three college students read a specially prepared text either with or without inserted questions. The text and the questions were presented on a computer terminal to allow measurement of reading times on short segments of material. Question groups performed better, relative to controls, on posttest items that repeated inserted questions and…
Silin, D; Lyubomska, O; Ludlow, M; Duprex, W P; Rima, B K
2007-12-01
We demonstrate that insertion of the open reading frame of enhanced green fluorescent protein (EGFP) into the coding sequence for the second hinge region of the viral L (large) protein (RNA-dependent RNA polymerase) attenuates a wild-type canine distemper virus. Moreover, we show that single intranasal immunization with this recombinant virus provides significant protection against challenge with the virulent parental virus. Protection against wild-type challenge was gained either after recovery of cellular immunity postimmunization or after development of neutralizing antibodies. Insertion of EGFP seems to result in overattenuation of the virus, while our previous experiments demonstrated that the insertion of an epitope tag into a similar position did not affect L protein function. Thus, a desirable level of attenuation could be reached by manipulating the length of the insert (in the second hinge region of the L protein), providing additional tools for optimization of controlled attenuation. This strategy for controlled attenuation may be useful for a "quick response" in vaccine development against well-known and "new" viral infections and could be combined efficiently with other strategies of vaccine development and delivery systems.
Silin, D.; Lyubomska, O.; Ludlow, M.; Duprex, W. P.; Rima, B. K.
2007-01-01
We demonstrate that insertion of the open reading frame of enhanced green fluorescent protein (EGFP) into the coding sequence for the second hinge region of the viral L (large) protein (RNA-dependent RNA polymerase) attenuates a wild-type canine distemper virus. Moreover, we show that single intranasal immunization with this recombinant virus provides significant protection against challenge with the virulent parental virus. Protection against wild-type challenge was gained either after recovery of cellular immunity postimmunization or after development of neutralizing antibodies. Insertion of EGFP seems to result in overattenuation of the virus, while our previous experiments demonstrated that the insertion of an epitope tag into a similar position did not affect L protein function. Thus, a desirable level of attenuation could be reached by manipulating the length of the insert (in the second hinge region of the L protein), providing additional tools for optimization of controlled attenuation. This strategy for controlled attenuation may be useful for a “quick response” in vaccine development against well-known and “new” viral infections and could be combined efficiently with other strategies of vaccine development and delivery systems. PMID:17898047
Does Needle Rotation Improve Lesion Targeting?
Badaan, Shadi; Petrisor, Doru; Kim, Chunwoo; Mozer, Pierre; Mazilu, Dumitru; Gruionu, Lucian; Patriciu, Alex; Cleary, Kevin; Stoianovici, Dan
2011-01-01
Background Image-guided robots are manipulators that operate based on medical images. Perhaps the most common class of image-guided robots are robots for needle interventions. Typically, these robots actively position and/or orient a needle guide, but needle insertion is still done by the physician. While this arrangement may have safety advantages and keep the physician in control of needle insertion, actuated needle drivers can incorporate other useful features. Methods We first present a new needle driver that can actively insert and rotate a needle. With this device we investigate the use of needle rotation in controlled in-vitro experiments performed with a specially developed revolving needle driver. Results These experiments show that needle rotation can improve targeting and may reduce errors by as much as 70%. Conclusion The new needle driver provides a unique kinematic architecture that enables insertion with a compact mechanism. Perhaps the most interesting conclusion of the study is that lesions of soft tissue organs may not be perfectly targeted with a needle without using special techniques, either manually or with a robotic device. The results of this study show that needle rotation may be an effective method of reducing targeting errors. PMID:21360796
Force-controlled automatic microassembly of tissue engineering scaffolds
NASA Astrophysics Data System (ADS)
Zhao, Guoyong; Teo, Chee Leong; Hutmacher, Dietmar Werner; Burdet, Etienne
2010-03-01
This paper presents an automated system for 3D assembly of tissue engineering (TE) scaffolds made from biocompatible microscopic building blocks with relatively large fabrication error. It focuses on the pin-into-hole force control developed for this demanding microassembly task. A beam-like gripper with integrated force sensing at a 3 mN resolution with a 500 mN measuring range is designed, and is used to implement an admittance force-controlled insertion using commercial precision stages. Visual-based alignment followed by an insertion is complemented by a haptic exploration strategy using force and position information. The system demonstrates fully automated construction of TE scaffolds with 50 microparts whose dimension error is larger than 5%.
Hein, Cindy; Owen, Harry; Plummer, John
2010-02-01
Major resuscitation councils endorse the use of the laryngeal mask airway (LMA) by paramedics for lifesaving airway interventions. Learning and maintaining adequate skill level is important for patient safety. The aim of this project was to develop a training program that provides student paramedics with initial knowledge and experience in LMA insertion skills but equally important to provide ongoing skill retention. After ethics approval and informed consent, 55 first year Paramedic degree students watched a manufacturer's LMA instruction video and practiced insertion in three different part task trainers. Six months later, subjects were randomized to an intervention (reviewing the video and 10 minutes unsupervised practice) or control group before participating in a high-fidelity simulated clinical scenario. For equity of training, the control group received the intervention after the scenario. Main outcomes measured were time to insertion; success rate; and LMA skill retention (sum of LMA orientation; cuff inflation; bite block; securing; patient positioning; and overall subject performance). Fifty subjects completed the study. Those in the intervention group displayed significantly shorter insertion times (P = 0.029), fewer attempts to achieve success (P = 0.033), and had significantly higher LMA skill performance levels (P = 0.019) at 6 months. We devised a short intervention based on our training program using a video and practice in part task trainers. In an assessment using high-fidelity simulation, we demonstrated significant improvements in maintenance of LMA insertion skills in student paramedics at 6 months. Our model of just-in-time assessment and reinforcement of training prevents skill decay and has implications for healthcare skills training in general.
NASA Astrophysics Data System (ADS)
Cheng, Jian-jun; Lei, Jia-qiang; Li, Sheng-yu; Wang, Hai-feng
2016-06-01
The inclined inserting-type sand fence is a novel sand retaining wall adopted along the Lanxin High-Speed Railway II in Xinjiang for controlling and blocking sand movement. To verify the effectiveness of the new fence structure for sand prevention, a wind tunnel test was used for flow field test simulation of the sand fence. The results indicate that the inclined inserting-type sand fence was able to deflect the flow of the sand and was able to easily form an upward slant acceleration zone on the leeward side of the sand fence. As shown by the percentage change in sand collection rates on the windward side and the leeward side of the sand fence, the sand flux per unit area at 4 m height in the slant upward direction increased on the leeward side of the inclined inserting-type sand fence. By comparing the flow fields, this site is an acceleration zone, which also reaffirms the correspondence of wind-sand flow fields with the spatial distribution characteristic of the wind-carried sand motion. The field sand collection data indicates that under the effects of the inclined inserting-type sand fence, the sandy air currents passing in front and behind the sand fence not only changed in quality, but the grain composition and particle size also significantly changed, suggesting that the inclined inserting-type sand fence has a sorting and filtering effect on the sandy air currents that passed through. The fence retained coarse particulates on the windward side and fine particulates within the shade of the wind on the leeward side.
Corrective shoes and inserts as treatment for flexible flatfoot in infants and children.
Wenger, D R; Mauldin, D; Speck, G; Morgan, D; Lieber, R L
1989-07-01
We performed a prospective study to determine whether flexible flatfoot in children can be influenced by treatment. One hundred and twenty-nine children who had been referred by pediatricians, and for whom the radiographic findings met the criteria for flatfoot, were randomly assigned to one of four groups: Group I, controls; Group II, treatment with corrective orthopaedic shoes; Group III, treatment with a Helfet heel-cup; or Group IV, treatment with a custom-molded plastic insert. All of the patients in Groups II, III, and IV had a minimum of three years of treatment, and ninety-eight patients whose compliance with the protocol was documented completed the study. Analysis of radiographs before treatment and at the most recent follow-up demonstrated a significant improvement in all groups (p less than 0.01), including the controls, and no significant difference between the controls and the treated patients (p greater than 0.4). We concluded that wearing corrective shoes or inserts for three years does not influence the course of flexible flatfoot in children.
Design and testing of microfabricated surgical tools for large animal probe insertion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jorgensen, Shelly
Neural probes provide therapeutic stimulation for neuropsychiatric disorders or record neural activity to investigate the workings of the brain. Researchers utilize 6 mm long temporary silicon stiffeners attached with biodissolvable adhesive to insert flexible neural probes into rat brains, but increasing the probe length fivefold makes inserting large animal probes a significant challenge because of an increased potential for buckling. This study compared the insertion success rates of 6 mm and 30 mm long silicon stiffeners that were 80 μm wide and 30 μm thick, and ascertained the material thickness and modulus of elasticity that would provide successful insertion formore » a 30 mm probe. Using a microdrive, stiffeners were inserted into an agarose brain phantom at controlled insertion speeds while being video-recorded. Twenty-five percent of the 30 mm silicon stiffeners fully inserted at speeds approximately four times higher than the target rate of 0.13 mm/s, while 100 percent of the 6 mm silicon stiffeners inserted successfully at target speed. Critical buckling loads (P cr) were calculated for the 6 mm and 30 mm silicon stiffeners, and for 30 mm diamond and tungsten stiffeners, with thicknesses varying from 30-80 μm. Increasing the thickness of the material by 10 μm, 20 μm and 30 μm improved the P cr by 2.4, 4.7 and 8.2 times, respectively, independent of the material, and substituting diamond for silicon multiplied the buckling capacity by 5.0 times. Stiffeners made of silicon for large animal probe insertion are not strong enough to withstand buckling upon insertion without a significant increase in thickness. Replacing silicon with diamond and increasing the thickness of the stiffener to 50 μm would afford a stiffener with the same P cr capacity as the 6 mm silicon stiffener that had a 100 percent insertion success rate. Experiments should continue with diamond to determine a minimum thickness that will ensure successful insertions and provide an adequate margin of safety.« less
Batisson, Isabelle; Guimond, Marie-Pierre; Girard, Francis; An, Hongyan; Zhu, Chengru; Oswald, Eric; Fairbrother, John M.; Jacques, Mario; Harel, Josée
2003-01-01
Nonenterotoxigenic porcine Escherichia coli strains belonging to the serogroup O45 have been associated with postweaning diarrhea in swine and adhere to intestinal epithelial cells in a characteristic attaching and effacing (A/E) pattern. O45 porcine enteropathogenic E. coli (PEPEC) strain 86-1390 induces typical A/E lesions in a pig ileal explant model. Using TnphoA transposon insertion mutagenesis on strain 86-1390, we found a mutant that did not induce A/E lesions. The insertion was identified in a gene designated paa (porcine A/E-associated gene). Sequence analysis of paa revealed an open reading frame of 753 bp encoding a 27.6-kDa protein which displayed 100, 51.8, and 49% homology with Paa of enterohemorrhagic E. coli O157:H7 strains (EDL933 and Sakai), PEB3 of Campylobacter jejuni, and AcfC of Vibrio cholerae, respectively. Chromosomal localization studies indicated that the region containing paa was inserted between the yciD and yciE genes at about 28.3 min of the E. coli K-12 chromosome. The presence of paa and eae sequences in the porcine O45 strains is highly correlated with the A/E phenotype. However, the observation that three eae-positive but paa-negative PEPEC O45 strains were A/E negative provides further evidence for the importance of the paa gene in the A/E activity of O45 strains. As well, the complementation of the paa mutant restored the A/E activity of the 86-1390 strain, showing the involvement of Paa in PEPEC pathogenicity. These observations suggest that Paa contributes to the early stages of A/E E. coli virulence. PMID:12874331
Batisson, Isabelle; Guimond, Marie-Pierre; Girard, Francis; An, Hongyan; Zhu, Chengru; Oswald, Eric; Fairbrother, John M; Jacques, Mario; Harel, Josée
2003-08-01
Nonenterotoxigenic porcine Escherichia coli strains belonging to the serogroup O45 have been associated with postweaning diarrhea in swine and adhere to intestinal epithelial cells in a characteristic attaching and effacing (A/E) pattern. O45 porcine enteropathogenic E. coli (PEPEC) strain 86-1390 induces typical A/E lesions in a pig ileal explant model. Using TnphoA transposon insertion mutagenesis on strain 86-1390, we found a mutant that did not induce A/E lesions. The insertion was identified in a gene designated paa (porcine A/E-associated gene). Sequence analysis of paa revealed an open reading frame of 753 bp encoding a 27.6-kDa protein which displayed 100, 51.8, and 49% homology with Paa of enterohemorrhagic E. coli O157:H7 strains (EDL933 and Sakai), PEB3 of Campylobacter jejuni, and AcfC of Vibrio cholerae, respectively. Chromosomal localization studies indicated that the region containing paa was inserted between the yciD and yciE genes at about 28.3 min of the E. coli K-12 chromosome. The presence of paa and eae sequences in the porcine O45 strains is highly correlated with the A/E phenotype. However, the observation that three eae-positive but paa-negative PEPEC O45 strains were A/E negative provides further evidence for the importance of the paa gene in the A/E activity of O45 strains. As well, the complementation of the paa mutant restored the A/E activity of the 86-1390 strain, showing the involvement of Paa in PEPEC pathogenicity. These observations suggest that Paa contributes to the early stages of A/E E. coli virulence.
Udho, Eshwar; Jakes, Karen S.; Finkelstein, Alan
2012-01-01
TonB-dependent transporters (TBDTs), which transport iron-chelating siderophores and vitamin B12 across the outer membrane of gram negative bacteria, share a conserved architecture of a 22-stranded beta-barrel with an amino-terminal plug domain occluding the barrel. We previously reported that we could induce TBDTs to reversibly open in planar lipid bilayers via the use of urea and that these channels were responsive to physiological concentrations of ligands. Here we report that in the presence of urea, trypsin can cleave the amino-terminal 67 residues of the plug of the TonB-dependent transporter FhuA, as assessed by gel shift and mass spectrometry assays. On the bilayer, trypsin treatment in the presence of urea resulted in the induced conductance no longer being reversed upon removal of urea, suggesting that urea opens intact FhuA channels by pulling the plug at least partly out of the barrel, and that removal of the urea then allows reinsertion of the plug into the barrel. When expressed separately, the FhuA plug domain was found to be a mostly unfolded structure that was able to occlude isolated FhuA beta-barrels inserted into the membrane. Thus, although folded in the barrel, the plug need not be folded upon exiting the barrel. The rate of insertion of the beta-barrels into the membrane was tremendously increased in the presence of an osmotic gradient provided by either urea or glycerol. Negative staining electron microscopy showed that FhuA in a detergent solution formed vesicles, thus explaining why an osmotic gradient promoted the insertion of FhuA into membranes. PMID:22846061
Yang, Cui; Latkin, Carl; Tobin, Karin; Seal, David; Koblin, Beryl; Chander, Geetanjali; Siconolfi, Daniel; Flores, Stephen; Spikes, Pilgrim
2018-05-19
Despite the high HIV incidence and prevalence among black men who have sex with men (BMSM), little research has examined partner characteristics, partner seeking venue, sexual position, substance use, and sexual risk behavior at the sex event-level among BMSM. Using the baseline data from a multi-site study of 807 BMSM stratified by their HIV status, the goal of this study was to conduct a detailed event-level analysis of 1577 male anal sex events to assess the factors associated with condomless anal intercourse (CLAI) with a HIV-discordant or HIV status-unknown partner. We found CLAI with an HIV-discordant or unknown HIV status partner among HIV-negative BMSM was negatively associated with having sex with a main partner, and was positively associated with taking both receptive and insertive sexual positions during sex. As compared to a sex partner met at bar, night club or dance club, HIV-positive BMSM were less likely to engage in CLAI with HIV-discordant and unknown HIV status partner met at party or friend's house or at community organizations. HIV-positive BMSM had lower odds of engaging in CLAI with HIV-discordant and unknown HIV status partner if they had insertive sexual position or both receptive and insertive sexual positions. These results underscore the importance of delineating unique sex event-level factors associated with sexual risk behavior depending on individuals' HIV status. Our findings suggest event-level partner characteristics, sexual position, and partner seeking venues may contribute to disparities in HIV incidence.
Mackesy-Amiti, Mary Ellen; Fendrich, Michael; Johnson, Timothy P
2010-07-01
This study examines the relationship between self-reported symptoms of substance dependence and risky sexual behavior among 187 HIV-negative men who have sex with men. In a supplement to a Chicago household survey, using random probability sampling, men who reported consensual sex with other men or who identified as gay or bisexual were selected for interviews. Participants reported on sexual behavior, substance use, and symptoms of substance dependence related to past year use of alcohol, marijuana, cocaine, and sedatives, tranquilizers or pain relievers. Risky sexual behavior was defined as unprotected insertive or receptive anal intercourse plus having multiple partners, casual partners, or a partner who was HIV positive or of unknown serostatus. Risky sexual behavior in the past six months was significantly and positively associated with alcohol dependence symptoms, cocaine dependence symptoms (receptive only), and prescription drug dependence symptoms (insertive only). Confirmatory factor analyses revealed that dependence symptoms loaded on separate factors by substance, which in turn loaded on an overarching dependence symptoms factor. In structural equation models, individual substance factors were not significantly associated with sexual risk behavior, however the higher order dependence symptoms factor was significantly and positively associated with both receptive and insertive risk behavior. MSM with symptoms of multiple substance use dependencies are more likely to be engaged in sexual behavior that places them at risk for acquiring HIV and other sexually transmitted infections. Alcohol and drug abuse treatment providers should be aware of the need for HIV testing and counseling in this population. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.
Kolappan, Subramaniapillai; Roos, Justin; Yuen, Alex S W; Pierce, Owen M; Craig, Lisa
2012-05-01
The type IV pili are helical filaments found on many Gram-negative pathogenic bacteria, with multiple diverse roles in pathogenesis, including microcolony formation, adhesion, and twitching motility. Many pathogenic enterotoxigenic Escherichia coli (ETEC) isolates express one of two type IV pili belonging to the type IVb subclass: CFA/III or Longus. Here we show a direct correlation between CFA/III expression and ETEC aggregation, suggesting that these pili, like the Vibrio cholerae toxin-coregulated pili (TCP), mediate microcolony formation. We report a 1.26-Å resolution crystal structure of CofA, the major pilin subunit from CFA/III. CofA is very similar in structure to V. cholerae TcpA but possesses a 10-amino-acid insertion that replaces part of the α2-helix with an irregular loop containing a 3(10)-helix. Homology modeling suggests a very similar structure for the Longus LngA pilin. A model for the CFA/III pilus filament was generated using the TCP electron microscopy reconstruction as a template. The unique 3(10)-helix insert fits perfectly within the gap between CofA globular domains. This insert, together with differences in surface-exposed residues, produces a filament that is smoother and more negatively charged than TCP. To explore the specificity of the type IV pilus assembly apparatus, CofA was expressed heterologously in V. cholerae by replacing the tcpA gene with that of cofA within the tcp operon. Although CofA was synthesized and processed by V. cholerae, no CFA/III filaments were detected, suggesting that the components of the type IVb pilus assembly system are highly specific to their pilin substrates.
Nano-composite insert in 1D waveguides for control of elastic power flow
NASA Astrophysics Data System (ADS)
Vignesh, P. S.; Mitra, Mira; Gopalakrishnan, S.
2007-01-01
In this paper, carbon nanotube embedded polymer composite/nano-composites are used to regulate power flow from its source to other parts of the structure. This is done by inserting nano-composite strips in the waveguides which are modelled here as isotropic Euler-Bernoulli beams with axial, transverse and rotational degrees of freedom. The power flow is due to wave propagation resulting from a high frequency broadband impulse load. The underlying concept is that the high stiffness of the insert reduces the wave transmission between different parts of the structures. The simulations are done using a wavelet based spectral finite element (WSFE) technique which is specially tailored for such high frequency wave propagation analysis. Numerical experiments are performed to illustrate the use of inserts in maintaining the power flow in a certain region of the structure below a given threshold value which may be specified depending on various applications. The effects of parameters such as the volume fraction of carbon nanotube (CNT) in the polymer, and the length and position of the inserts are also studied. These studies help in defining the optimal volume fraction of CNT and length of the insert for a specified structural configuration.
Zinn, W.H.; Ross, H.V.
1958-11-18
A control rod is described for a nuclear reactor. In certaln reactor designs it becomes desirable to use a control rod having great width but relatively llttle thickness. This patent is addressed to such a need. The neutron absorbing material is inserted in a triangular tube, leaving volds between the circular insert and the corners of the triangular tube. The material is positioned within the tube by the use of dummy spacers to achleve the desired absorption pattern, then the ends of the tubes are sealed with suitable plugs. The tubes may be welded or soldered together to form two flat surfaces of any desired width, and covered with sheetmetal to protect the tubes from damage. This design provides a control member that will not distort under the action of outside forces or be ruptured by gases generated within the jacketed control member.
Closure for milliliter scale bioreactor
Klein, David L.; Laidlaw, Robert D.; Andronaco, Gregory; Boyer, Stephen G.
2010-12-14
A closure for a microreactor includes a cap that is configured to be inserted into a well of the microreactor. The cap, or at least a portion of the cap, is compliant so as to form a seal with the well when the cap is inserted. The cap includes an aperture that provides an airway between the inside of the well to the external environment when the cap is inserted into the well. A porous plug is inserted in the aperture, e.g., either directly or in tube that extends through the aperture. The porous plug permits gas within the well to pass through the aperture while preventing liquids from passing through to reduce evaporation and preventing microbes from passing through to provide a sterile environment. A one-way valve may also be used to help control the environment in the well.
Francisella tularensis Molecular Typing Using Differential Insertion Sequence Amplification
2011-08-01
16 May 2011 Tularemia is a potentially fatal disease that is caused by the highly infectious and zoonotic pathogen Francisella tularensis. Despite...and characterizations of tularemia source outbreaks. Francisella tularensis is a facultative intracellular bacterium and the causative agent of the...zoonotic disease tularemia ( 10). This Gram-negative microbe is highly infectious, with as few as 10 organisms being capable of causing disease in
Heinrichs, D E; Poole, K
1996-01-01
The product of the pchR gene, an AraC-like regulatory protein, is required for production of the FptA ferric pyochelin receptor in response to iron limitation and pyochelin (D. E. Heinrichs and K. Poole, J. Bacteriol. 175:5882-5889, 1993). The influence of iron, pyochelin, PchR, and FptA on fptA and pchR gene expression was assessed with fptA-lacZ and pchR-lacZ transcriptional fusions. As was expected, the expression of fptA decreased dramatically following the inactivation of pchR by the insertion of an OmegaHg cartridge, although the effect (> 10-fold) was not as dramatic as that of pyochelin deficiency, which obviated fptA gene expression. Insertional inactivation of pchR in a pyochelin-deficient (Pch-) background restored fptA expression to levels observed in the pyochelin-producing (Pch+) PchR- strain, suggesting that PchR represses fptA expression in the absence of pyochelin. Consistent with this, the cloned gene caused a five-fold decrease in the expression of the fptA-lacZ fusion in Escherichia coli. pchR gene expression was inducible by iron limitation, a result in agreement with the previous identification of a Fur box upstream of the gene, although the magnitude of the induction was less than that observed for fptA in response to iron limitation. Expression of pchR was effectively absent in a pyochelin-deficient strain, and insertional inactivation of pchR in a Pch+ or Pch- background caused an increase in pchR gene expression. PchR, thus, negatively regulates its own expression. Two related heptameric sequences, CGAGGAA and CGTGGAT, were identified upstream of the putative -35 region of both fptA and pchR and may function as a binding site for PchR. Insertional inactivation of fptA caused a marked decrease in fptA expression in a Pch+ background and obviated the apparent repression of fptA expression in a Pch- background, reminiscent of the effect of a pchR mutation. The fptA mutant did not, however, exhibit a defect in pchR expression. Interestingly, fptA mutants were unable to grow in the presence of pyochelin, suggesting that FptA is the sole outer membrane receptor for ferric pyochelin. These data indicate that PchR functions as both an activator and a repressor in controlling the expression of fptA and pchR. The involvement of FptA in this control is unclear, although it may be important in mediating the pyochelin effect on fptA expression, possibly by modulating PchR activity. PMID:8626326
Niedzielski, K; Zwierzchowski, H
1993-01-01
The 3 year study included 469 children with flat feet in preschool and school age from a section of the town of Lodz. In 2 separate age groups the influence of exercises and/or hindfoot supinating inserts on the deformity regression has been assessed. The results were being compared at every stage of the study with the deformity evaluations in control group of not treated children. The best results have been recorded in children doing exercises and wearing inserts--in 50 percent the deformity retreated. Little potential for self correction of this deformity indicates mandatory treatment of all children with flat feet.
Wen, Jie; Yu, Qun; Chen, Haiyan; Chen, Niannian; Huang, Shourong; Cai, Wei
2017-01-01
The placement of a peripherally inserted central venous catheter (PICC) is an essential procedure in neonatal intensive care units (NICU). The aim of this study was to determine the risk of PICC complications in NICU, and further identify the effects of PICC complications on body weight gain in premature infants. A total of 304 premature infants who had a PICC inserted in NICU were enrolled in this study. The weight-for-age z-score (WAZ) at the time of PICC insertion and removal were calculated, and changes of WAZ in different groups were compared using a t-test. Risk factors for PICC complications were assessed using the chi-squared test and multiple logistic regression analysis. Thirty (9.97%) PICCs were removed due to complications. Of them, 14 PICCs were removed because of non-infectious complications and 16 PICCs were removed for central-line-associated bloodstream infections (CLABSIs). Multiple logistic regression analysis showed that premature infants with birth weight >1,500 g were less likely to have PICC complications than infants with birth weight <=1,500 g (OR, 0.29; 95% CI: 0.10-0.82; p=0.020). In addition, the changes in WAZ between PICC insertion and removal were significantly different in both infectious (-0.144±0.122, p<0.005) and non-infectious (-0.65±0.528, p<0.001) complications groups, compared with the no complications group (0.291±0.552). Findings from this study suggest that birth weight is a risk factor for PICC-associated complications in the NICU, and both infectious and non-infectious PICC complications are associated with poor body weight gain in premature infants.
Junqueira, Beatriz L P; Connolly, Bairbre; Abla, Oussama; Tomlinson, George; Amaral, Joao G
2010-09-15
The objective of this study was to determine whether severe neutropenia on the day of port-a-catheter (PORT) insertion was a risk factor for catheter-associated infection (CAI) in children with acute lymphoblastic leukemia (ALL). This was a retrospective study of children with ALL who had a PORT insertion between January 2005 and August 2008. Early (≤ 30 days) and late (>30 days) postprocedure complications were reviewed. The length of follow-up ranged between 7 months and 42 months. In total, 192 PORTs were inserted in 179 children. There were 43 CAIs (22%), and the infection rate was 0.35 per 1000 catheter-days. The CAI rate (15%) in children who had severe neutropenia on the day of the procedure did not differ statistically from the CAI rate (24%) in children who did not have severe neutropenia (P = .137). Conversely, patients with severe neutropenia who had a CAI were more likely to have their PORT removed (P = .019). The most common organisms to cause catheter removal were coagulase-negative Staphylococcus and Staphylococcus aureus. Patients with high-risk ALL had a statistically significant higher incidence of late CAI than patients with standard-risk ALL (P = .012). Age (P = .272), positive blood culture preprocedure (P = 1.0), and dexamethasone use (P = .201) were not risk factors for CAI. Patients who had an early CAI did not have a greater chance of having a late CAI. The catheter infection-free survival rate at 1 year was 88.6%. The current results indicated that severe neutropenia on the day of PORT insertion does not increase the risk of CAI in children with ALL. © 2010 American Cancer Society.
Bacterial Hsp70 (DnaK) and mammalian Hsp70 interact differently with lipid membranes.
Lopez, Victor; Cauvi, David M; Arispe, Nelson; De Maio, Antonio
2016-07-01
The cellular response to stress is orchestrated by the expression of a family of proteins termed heat shock proteins (hsp) that are involved in the stabilization of basic cellular processes to preserve cell viability and homeostasis. The bulk of hsp function occurs within the cytosol and subcellular compartments. However, some hsp have also been found outside cells released by an active mechanism independent of cell death. Extracellular hsp act as signaling molecules directed at activating a systemic response to stress. The export of hsp requires the translocation from the cytosol into the extracellular milieu across the plasma membrane. We have proposed that membrane insertion is the initial step in this export process. We investigated the interaction of the major inducible hsp from mammalian (Hsp70) and bacterial (DnaK) species with liposomes. We found that mammalian Hsp70 displayed a high specificity for negatively charged phospholipids, such as phosphatidyl serine, whereas DnaK interacted with all lipids tested regardless of the charge. Both proteins were inserted into the lipid bilayer as demonstrated by resistance to acid or basic washes that was confirmed by partial protection from proteolytic cleavage. Several regions of mammalian Hsp70 were inserted into the membrane with a small portion of the N-terminus end exposed to the outer phase of the liposome. In contrast, the N-terminus end of DnaK was inserted into the membrane, exposing the C-terminus end outside the liposome. Mammalian Hsp70 was found to make high oligomeric complexes upon insertion into the membranes whereas DnaK only formed dimers within the lipid bilayer. These observations suggest that both Hsp70s interact with lipids, but mammalian Hsp70 displays a high degree of specificity and structure as compared with the bacterial form.
Yoshida, Asuka; Samal, Siba K.
2017-01-01
Avian paramyxovirus serotype 3 (APMV-3) causes infection in a wide variety of avian species, but it does not cause apparent diseases in chickens. On the contrary, APMV-1, also known as Newcastle disease virus (NDV), can cause severe disease in chickens. Currently, natural low virulence strains of NDV are used as live-attenuated vaccines throughout the world. NDV is also being evaluated as a vaccine vector against poultry pathogens. However, due to routine vaccination programs, chickens often possess pre-existing antibodies against NDV, which may cause the chickens to be less sensitive to recombinant NDV vaccines expressing antigens of other avian pathogens. Therefore, it may be possible for an APMV-3 vector vaccine to circumvent this issue. In this study, we determined the optimal insertion site in the genome of APMV-3 for high level expression of a foreign gene. We generated recombinant APMV-3 viruses expressing the green fluorescent protein (GFP) by inserting the GFP gene at five different intergenic regions in the genome. The levels of GFP transcription and translation were evaluated. Interestingly, the levels of GFP transcription and translation did not follow the 3′-to-5′ attenuation mechanism of non-segmented, negative-sense RNA viruses. The insertion of GFP gene into the P-M gene junction resulted in higher level of expression of GFP than when the gene was inserted into the upstream N-P gene junction. Unlike NDV, insertion of GFP did not attenuate the growth efficiency of AMPV-3. Thus, APMV-3 could be a more useful vaccine vector for avian pathogens than NDV. PMID:28473820
Yoshida, Asuka; Samal, Siba K
2017-01-01
Avian paramyxovirus serotype 3 (APMV-3) causes infection in a wide variety of avian species, but it does not cause apparent diseases in chickens. On the contrary, APMV-1, also known as Newcastle disease virus (NDV), can cause severe disease in chickens. Currently, natural low virulence strains of NDV are used as live-attenuated vaccines throughout the world. NDV is also being evaluated as a vaccine vector against poultry pathogens. However, due to routine vaccination programs, chickens often possess pre-existing antibodies against NDV, which may cause the chickens to be less sensitive to recombinant NDV vaccines expressing antigens of other avian pathogens. Therefore, it may be possible for an APMV-3 vector vaccine to circumvent this issue. In this study, we determined the optimal insertion site in the genome of APMV-3 for high level expression of a foreign gene. We generated recombinant APMV-3 viruses expressing the green fluorescent protein (GFP) by inserting the GFP gene at five different intergenic regions in the genome. The levels of GFP transcription and translation were evaluated. Interestingly, the levels of GFP transcription and translation did not follow the 3'-to-5' attenuation mechanism of non-segmented, negative-sense RNA viruses. The insertion of GFP gene into the P-M gene junction resulted in higher level of expression of GFP than when the gene was inserted into the upstream N-P gene junction. Unlike NDV, insertion of GFP did not attenuate the growth efficiency of AMPV-3. Thus, APMV-3 could be a more useful vaccine vector for avian pathogens than NDV.
NASA Technical Reports Server (NTRS)
Smeltzer, M. S.; Hart, M. E.; Iandolo, J. J.; Spooner, B. S. (Principal Investigator)
1993-01-01
We recently described a Tn551 insertion in the chromosome of Staphylococcus aureus S6C that resulted in drastically reduced expression of extracellular lipase (M. S. Smeltzer, S. R. Gill, and J. J. Iandolo, J. Bacteriol. 174:4000-4006, 1992). The insertion was localized to a chromosomal site (designated omega 1058) distinct from the lipase structural gene (geh) and the accessory gene regulator (agr), both of which were structurally intact in the lipase-negative (Lip-) mutants. In this report, we describe a phenotypic comparison between strains S6C, a hyperproducer of enterotoxin B; KSI9051, a derivative of S6C carrying the Tn551 insertion at omega 1058; ISP546, an 8325-4 strain that carries a Tn551 insertion in the agr locus; and ISP479C, the parent strain of ISP546 cured of the Tn551 delivery plasmid pI258repA36. Compared with their respective parent strains, ISP546 and KSI9051 produced greatly reduced amounts of lipase, alpha-toxin, delta-toxin, protease, and nuclease. KSI9051 also produced reduced amounts of staphylococcal enterotoxin B. Coagulase production was increased in ISP546 but not in KSI9051. Using a mouse model, we also demonstrated that ISP546 and KSI9051 were far less virulent than ISP479C and S6C. We have designated the genetic element defined by the Tn551 insertion at omega 1058 xpr to denote its role as a regulator of extracellular protein synthesis. We conclude that xpr and agr are similar and possibly interactive regulatory genes that play an important role in pathogenesis of staphylococcal disease.
A. Dan Wilson; D.G. Lester
1997-01-01
Second-year field evaluations of four trench insert materials, including water-permeable Typar® polypropylene spunbonded fabric, Biobarrier® or Typar® with trifluralin-impregnated nodules, and water-impermeable polyethylene Geomembrane liners of two thicknesses (20 and 30 mil), were conducted to further test the effectiveness of these physical and/or chemical barriers...
Yamashita, Joselene Martinelli; Moura-Grec, Patrícia Garcia de; Freitas, Adriana Rodrigues de; Sales-Peres, Arsênio; Groppo, Francisco Carlos; Ceneviva, Reginaldo; Sales-Peres, Sílvia Helena de Carvalho
2015-01-01
The aim of this study was to identify the impact of oral disease on the quality of life of morbid obese and normal weight individuals. Cohort was composed of 100 morbid-obese and 50 normal-weight subjects. Dental caries, community periodontal index, gingival bleeding on probing (BOP), calculus, probing pocket depth, clinical attachment level, dental wear, stimulated salivary flow, and salivary pH were used to evaluate oral diseases. Socioeconomic and the oral impacts on daily performances (OIDP) questionnaires showed the quality of life in both groups. Unpaired Student, Fisher's Exact, Chi-Square, Mann-Whitney, and Multiple Regression tests were used (p<0.05). Obese showed lower socio-economic level than control group, but no differences were found considering OIDP. No significant differences were observed between groups considering the number of absent teeth, bruxism, difficult mastication, calculus, initial caries lesion, and caries. However, saliva flow was low, and the salivary pH was changed in the obese group. Enamel wear was lower and dentine wear was higher in obese. More BOP, insertion loss, and periodontal pocket, especially the deeper ones, were found in obese subjects. The regression model showed gender, smoking, salivary pH, socio-economic level, periodontal pocket, and periodontal insertion loss significantly associated to obesity. However, both OIDP and BOP did not show significant contribution to the model. The quality of life of morbid obese was more negatively influenced by oral disease and socio-economic factors than in normal weight subjects.
Nycz, Christopher J; Gondokaryono, Radian; Carvalho, Paulo; Patel, Nirav; Wartenberg, Marek; Pilitsis, Julie G; Fischer, Gregory S
2018-01-01
The use of magnetic resonance imaging (MRI) for guiding robotic surgical devices has shown great potential for performing precisely targeted and controlled interventions. To fully realize these benefits, devices must work safely within the tight confines of the MRI bore without negatively impacting image quality. Here we expand on previous work exploring MRI guided robots for neural interventions by presenting the mechanical design and assessment of a device for positioning, orienting, and inserting an interstitial ultrasound-based ablation probe. From our previous work we have added a 2 degree of freedom (DOF) needle driver for use with the aforementioned probe, revised the mechanical design to improve strength and function, and performed an evaluation of the mechanism’s accuracy and effect on MR image quality. The result of this work is a 7-DOF MRI robot capable of positioning a needle tip and orienting it’s axis with accuracy of 1.37 ± 0.06mm and 0.79° ± 0.41°, inserting it along it’s axis with an accuracy of 0.06 ± 0.07mm, and rotating it about it’s axis to an accuracy of 0.77° ± 1.31°. This was accomplished with no significant reduction in SNR caused by the robot’s presence in the MRI bore, ≤ 10.3% reduction in SNR from running the robot’s motors during a scan, and no visible paramagnetic artifacts. PMID:29696097
DeCaro, Renee; Peelle, Jonathan E; Grossman, Murray; Wingfield, Arthur
2016-01-01
Reduced hearing acuity is among the most prevalent of chronic medical conditions among older adults. An experiment is reported in which comprehension of spoken sentences was tested for older adults with good hearing acuity or with a mild-to-moderate hearing loss, and young adults with age-normal hearing. Comprehension was measured by participants' ability to determine the agent of an action in sentences that expressed this relation with a syntactically less complex subject-relative construction or a syntactically more complex object-relative construction. Agency determination was further challenged by inserting a prepositional phrase into sentences between the person performing an action and the action being performed. As a control, prepositional phrases of equivalent length were also inserted into sentences in a non-disruptive position. Effects on sentence comprehension of age, hearing acuity, prepositional phrase placement and sound level of stimulus presentations appeared only for comprehension of sentences with the more syntactically complex object-relative structures. Working memory as tested by reading span scores accounted for a significant amount of the variance in comprehension accuracy. Once working memory capacity and hearing acuity were taken into account, chronological age among the older adults contributed no further variance to comprehension accuracy. Results are discussed in terms of the positive and negative effects of sensory-cognitive interactions in comprehension of spoken sentences and lend support to a framework in which domain-general executive resources, notably verbal working memory, play a role in both linguistic and perceptual processing.
“Agrolistic” transformation of plant cells: Integration of T-strands generated in planta
Hansen, Geneviève; Chilton, Mary-Dell
1996-01-01
We describe a novel plant transformation technique, termed “agrolistic,” that combines the advantages of the Agrobacterium transformation system with the high efficiency of biolistic DNA delivery. Agrolistic transformation allows integration of the gene of interest without undesired vector sequence. The virulence genes virD1 and virD2 from Agrobacterium tumefaciens that are required in bacteria for excision of T-strands from the tumor-inducing plasmid were placed under the control of the CaMV35S promoter and codelivered with a target plasmid containing border sequences flanking the gene of interest. Transient expression assays in tobacco and in maize cells indicated that vir gene products caused strand-specific nicking in planta at the right border sequence, similar to VirD1/VirD2-catalyzed T-strand excision observed in Agrobacterium. Agrolistically transformed tobacco calli were obtained after codelivery of virD1 and virD2 genes together with a selectable marker flanked by border sequences. Some inserts exhibited right junctions with plant DNA that corresponded precisely to the sequence expected for T-DNA (portion of the tumor-inducing plasmid that is transferred to plant cells) insertion events. We designate these as “agrolistic” inserts, as distinguished from “biolistic” inserts. Both types of inserts were found in some transformed lines. The frequency of agrolistic inserts was 20% that of biolistic inserts. PMID:8962167
Bish, Lawrence T; Sleeper, Meg M; Reynolds, Caryn; Gazzara, Jeffrey; Withnall, Elanor; Singletary, Gretchen E; Buchlis, George; Hui, Daniel; High, Katherine A; Gao, Guangping; Wilson, James M; Sweeney, H Lee
2011-08-01
Derangements in calcium cycling have been described in failing hearts, and preclinical studies have suggested that therapies aimed at correcting this defect can lead to improvements in cardiac function and survival. One strategy to improve calcium cycling would be to inhibit phospholamban (PLB), the negative regulator of SERCA2a that is upregulated in failing hearts. The goal of this study was to evaluate the safety and efficacy of using adeno-associated virus (AAV)-mediated cardiac gene transfer of short hairpin RNA (shRNA) to knock down expression of PLB. Six dogs were treated with self-complementary AAV serotype 6 (scAAV6) expressing shRNA against PLB. Three control dogs were treated with empty AAV6 capsid, and two control dogs were treated with scAAV6 expressing dominant negative PLB. Vector was delivered via a percutaneously inserted cardiac injection catheter. PLB mRNA and protein expression were analyzed in three of six shRNA dogs between days 16 and 26. The other three shRNA dogs and five control dogs were monitored long-term to assess cardiac safety. PLB mRNA was reduced 16-fold, and PLB protein was reduced 5-fold, with treatment. Serum troponin elevation and depressed cardiac function were observed in the shRNA group only at 4 weeks. An enzyme-linked immunospot assay failed to detect any T cells reactive to AAV6 capsid in peripheral blood mononuclear cells, heart, or spleen. Microarray analysis revealed alterations in cardiac expression of several microRNAs with shRNA treatment. AAV6-mediated cardiac gene transfer of shRNA effectively knocks down PLB expression but is associated with severe cardiac toxicity. Toxicity may result from dysregulation of endogenous microRNA pathways.
Sleeper, Meg M.; Reynolds, Caryn; Gazzara, Jeffrey; Withnall, Elanor; Singletary, Gretchen E.; Buchlis, George; Hui, Daniel; High, Katherine A.; Gao, Guangping; Wilson, James M.; Sweeney, H. Lee
2011-01-01
Abstract Derangements in calcium cycling have been described in failing hearts, and preclinical studies have suggested that therapies aimed at correcting this defect can lead to improvements in cardiac function and survival. One strategy to improve calcium cycling would be to inhibit phospholamban (PLB), the negative regulator of SERCA2a that is upregulated in failing hearts. The goal of this study was to evaluate the safety and efficacy of using adeno-associated virus (AAV)-mediated cardiac gene transfer of short hairpin RNA (shRNA) to knock down expression of PLB. Six dogs were treated with self-complementary AAV serotype 6 (scAAV6) expressing shRNA against PLB. Three control dogs were treated with empty AAV6 capsid, and two control dogs were treated with scAAV6 expressing dominant negative PLB. Vector was delivered via a percutaneously inserted cardiac injection catheter. PLB mRNA and protein expression were analyzed in three of six shRNA dogs between days 16 and 26. The other three shRNA dogs and five control dogs were monitored long-term to assess cardiac safety. PLB mRNA was reduced 16-fold, and PLB protein was reduced 5-fold, with treatment. Serum troponin elevation and depressed cardiac function were observed in the shRNA group only at 4 weeks. An enzyme-linked immunospot assay failed to detect any T cells reactive to AAV6 capsid in peripheral blood mononuclear cells, heart, or spleen. Microarray analysis revealed alterations in cardiac expression of several microRNAs with shRNA treatment. AAV6-mediated cardiac gene transfer of shRNA effectively knocks down PLB expression but is associated with severe cardiac toxicity. Toxicity may result from dysregulation of endogenous microRNA pathways. PMID:21542669
Residual neural processing of musical sound features in adult cochlear implant users.
Timm, Lydia; Vuust, Peter; Brattico, Elvira; Agrawal, Deepashri; Debener, Stefan; Büchner, Andreas; Dengler, Reinhard; Wittfoth, Matthias
2014-01-01
Auditory processing in general and music perception in particular are hampered in adult cochlear implant (CI) users. To examine the residual music perception skills and their underlying neural correlates in CI users implanted in adolescence or adulthood, we conducted an electrophysiological and behavioral study comparing adult CI users with normal-hearing age-matched controls (NH controls). We used a newly developed musical multi-feature paradigm, which makes it possible to test automatic auditory discrimination of six different types of sound feature changes inserted within a musical enriched setting lasting only 20 min. The presentation of stimuli did not require the participants' attention, allowing the study of the early automatic stage of feature processing in the auditory cortex. For the CI users, we obtained mismatch negativity (MMN) brain responses to five feature changes but not to changes of rhythm, whereas we obtained MMNs for all the feature changes in the NH controls. Furthermore, the MMNs to deviants of pitch of CI users were reduced in amplitude and later than those of NH controls for changes of pitch and guitar timber. No other group differences in MMN parameters were found to changes in intensity and saxophone timber. Furthermore, the MMNs in CI users reflected the behavioral scores from a respective discrimination task and were correlated with patients' age and speech intelligibility. Our results suggest that even though CI users are not performing at the same level as NH controls in neural discrimination of pitch-based features, they do possess potential neural abilities for music processing. However, CI users showed a disrupted ability to automatically discriminate rhythmic changes compared with controls. The current behavioral and MMN findings highlight the residual neural skills for music processing even in CI users who have been implanted in adolescence or adulthood. -Automatic brain responses to musical feature changes reflect the limitations of central auditory processing in adult Cochlear Implant users.-The brains of adult CI users automatically process sound features changes even when inserted in a musical context.-CI users show disrupted automatic discriminatory abilities for rhythm in the brain.-Our fast paradigm demonstrate residual musical abilities in the brains of adult CI users giving hope for their future rehabilitation.
Residual Neural Processing of Musical Sound Features in Adult Cochlear Implant Users
Timm, Lydia; Vuust, Peter; Brattico, Elvira; Agrawal, Deepashri; Debener, Stefan; Büchner, Andreas; Dengler, Reinhard; Wittfoth, Matthias
2014-01-01
Auditory processing in general and music perception in particular are hampered in adult cochlear implant (CI) users. To examine the residual music perception skills and their underlying neural correlates in CI users implanted in adolescence or adulthood, we conducted an electrophysiological and behavioral study comparing adult CI users with normal-hearing age-matched controls (NH controls). We used a newly developed musical multi-feature paradigm, which makes it possible to test automatic auditory discrimination of six different types of sound feature changes inserted within a musical enriched setting lasting only 20 min. The presentation of stimuli did not require the participants’ attention, allowing the study of the early automatic stage of feature processing in the auditory cortex. For the CI users, we obtained mismatch negativity (MMN) brain responses to five feature changes but not to changes of rhythm, whereas we obtained MMNs for all the feature changes in the NH controls. Furthermore, the MMNs to deviants of pitch of CI users were reduced in amplitude and later than those of NH controls for changes of pitch and guitar timber. No other group differences in MMN parameters were found to changes in intensity and saxophone timber. Furthermore, the MMNs in CI users reflected the behavioral scores from a respective discrimination task and were correlated with patients’ age and speech intelligibility. Our results suggest that even though CI users are not performing at the same level as NH controls in neural discrimination of pitch-based features, they do possess potential neural abilities for music processing. However, CI users showed a disrupted ability to automatically discriminate rhythmic changes compared with controls. The current behavioral and MMN findings highlight the residual neural skills for music processing even in CI users who have been implanted in adolescence or adulthood. Highlights: -Automatic brain responses to musical feature changes reflect the limitations of central auditory processing in adult Cochlear Implant users.-The brains of adult CI users automatically process sound features changes even when inserted in a musical context.-CI users show disrupted automatic discriminatory abilities for rhythm in the brain.-Our fast paradigm demonstrate residual musical abilities in the brains of adult CI users giving hope for their future rehabilitation. PMID:24772074
Velmurugan, J.; Mirkin, M. V.; Svirsky, M. A.; Lalwani, A. K.; Llinas, R. R.
2014-01-01
A growing number of minimally invasive surgical and diagnostic procedures require the insertion of an optical, mechanical, or electronic device in narrow spaces inside a human body. In such procedures, precise motion control is essential to avoid damage to the patient’s tissues and/or the device itself. A typical example is the insertion of a cochlear implant which should ideally be done with minimum physical contact between the moving device and the cochlear canal walls or the basilar membrane. Because optical monitoring is not possible, alternative techniques for sub millimeter-scale distance control can be very useful for such procedures. The first requirement for distance control is distance sensing. We developed a novel approach to distance sensing based on the principles of scanning electrochemical microscopy (SECM). The SECM signal, i.e., the diffusion current to a microelectrode, is very sensitive to the distance between the probe surface and any electrically insulating object present in its proximity. With several amperometric microprobes fabricated on the surface of an insertable device, one can monitor the distances between different parts of the moving implant and the surrounding tissues. Unlike typical SECM experiments, in which a disk-shaped tip approaches a relatively smooth sample, complex geometries of the mobile device and its surroundings make distance sensing challenging. Additional issues include the possibility of electrode surface contamination in biological fluids and the requirement for a biologically compatible redox mediator. PMID:24845292
Satokawa, Y; Minami, I; Wakabayashi, N
2018-02-01
Oral appliances with an occlusal flat table are used as treatment dentures. However, the short-term effect of insertion of such oral appliances on chewing has not been reported. This study aimed to determine whether experimental and continuous insertion of oral appliances with an occlusal flat table has an effect on chewing efficiency and Oral Health Impact Profile (OHIP) in healthy participants. Ten participants each in the oral-appliance and control (no oral-appliance insertion) groups attended six data collection sessions for 5 consecutive days. Participants answered the OHIP questionnaire and underwent the chewing efficiency test. For each parameter, intergroup differences were investigated in terms of change from baseline to immediately after oral-appliance insertion (0 hour; P < .05) and from 0 hour to 24, 48, 72 and 96 hours after oral-appliance insertion (P < .05). There were significant differences between groups in the degree of change in chewing efficiency and OHIP scores for functional limitation, physical pain, physical disability and handicap from baseline to 0 hour (all, P < .001); among these, only OHIP scores for functional limitation and physical pain demonstrated significant differences in degree of change between the two groups at 96 hours after appliance insertion (P = .477 and .275, respectively). Differences between the two groups in the degree of change in other parameters were not significant. Insertion of oral appliances caused a decrease in chewing efficiency and an increase in OHIP scores. Continuous insertion improved functional limitation and physical pain within 96 hours. © 2017 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaede, S; Jordan, K; Western University, London, ON
Purpose: To present a customized programmable moving insert for the ArcCHECK™ phantom that can, in a single delivery, check both entrance dosimetry, while simultaneously verifying the delivery of respiratory-gated VMAT. Methods: The cylindrical motion phantom uses a computer-controlled stepping motor to move an insert inside a stationery sleeve. Insert motion is programmable and can include rotational motion in addition to linear motion along the axis of the cylinder. The sleeve fits securely in the bore of the ArcCHECK™. Interchangeable inserts, including an A1SL chamber, optically-stimulated luminescence dosimeters, radiochromic film, or 3D gels, allow this combination to be used for commissioning,more » routine quality assurance, and patient-specific dosimetric verification of respiratory-gated VMAT. Before clinical implementation, the effect of a moving insert on the ArcCHECK™ measurements was considered. First, the measured dose to the ArcCHECK™ containing multiple inserts in the static position was compared to the calculated dose during multiple VMAT treatment deliveries. Then, dose was measured under both sinusoidal and real-patient motion conditions to determine any effect of the moving inserts on the ArcCHECK™ measurements. Finally, dose was measured during gated VMAT delivery to the same inserts under the same motion conditions to examine any effect of various beam “on-and-off” and dose rate ramp “up-and-down”. Multiple comparisons between measured and calculated dose to different inserts were also considered. Results: The pass rate for the static delivery exceeded 98% for all measurements (3%/3mm), suggesting a valid setup for entrance dosimetry. The pass rate was not altered for any measurement delivered under motion conditions. A similar Result was observed under gated VMAT conditions, including agreement of measured and calculated dose to the various inserts. Conclusion: Incorporating a programmable moving insert within the ArcCHECK™ phantom provides an efficient verification of respiratory-gated VMAT delivery that is useful during commissioning, routine quality assurance, and patient-specific dose verification. Prototype phantom development and testing was performed in collaboration with Modus Medical Devices Inc. (London, ON). No financial support was granted.« less
Campos, Camila H; Ribeiro, Giselle R; Rodrigues Garcia, Renata C M
2018-05-01
Alzheimer disease (AD) can affect masticatory function, affecting oral health-related quality of life (OHRQoL). Whether oral rehabilitation with conventional removable prostheses can restore masticatory function and improve OHRQoL in these individuals is unknown. The purpose of this clinical study was to evaluate the influence of oral rehabilitation with removable prostheses on masticatory efficiency and OHRQoL in elders with and without AD. Thirty-two elders with mild AD (n=16, mean age=76.7 ±6.3 years) or without AD (n=16, mean age=75.2 ±4.4 years) were recruited. All participants first underwent masticatory efficiency and OHRQoL evaluations, and 2 months after insertion of new removable prostheses, the variables were reassessed. Masticatory efficiency was determined using the sieving method, and OHRQoL was measured by applying the Geriatric Oral Health Assessment Index (GOHAI). The data from the baseline and after insertion of the new removable prostheses were compared by paired t test. Group differences at each time point were assessed by t test (α=.05). After insertion of the new removable prostheses, masticatory efficiency and OHRQoL improved in both the elders with AD and the control. At baseline, elders with AD had lower masticatory efficiency and higher OHRQoL than controls (P<.05). After removable prosthesis insertion, elders with AD continued to show lower masticatory efficiency values than controls, but their OHRQoL was similar. Oral rehabilitation with new removable prostheses improved the masticatory efficiency and OHRQoL of elders with and without AD, although masticatory efficiency did not reach control levels in elders with AD. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Shabandokht-Zarmi, Hosniyeh; Bagheri-Nesami, Masoumeh; Shorofi, Seyed Afshin; Mousavinasab, Seyed Nouraddin
2017-11-01
This study was intended to examine the effect of selective soothing music on fistula puncture-related pain in hemodialysis patients. This is a randomized clinical trial in which 114 participants were selected from two hemodialysis units by means of a non-random, convenience sampling method. The participants were then allocated in three groups of music (N = 38), headphone (N = 38), and control (N = 38). The fistula puncture-related pain was measured 1 min after venipuncture procedure in all three groups. The music group listened to their self-selected and preferred music 6 min before needle insertion into a fistula until the end of procedure. The headphone group wore a headphone alone without listening to music 6 min before needle insertion into a fistula until the end of procedure. The control group did not receive any intervention from the research team during needle insertion into a fistula. The pain intensity was measured immediately after the intervention in all three groups. This study showed a significant difference between the music and control groups, and the music and headphone groups in terms of the mean pain score after the intervention. However, the analysis did not indicate any significant difference between the headphone and control groups with regard to the mean pain score after the intervention. It is concluded that music can be used effectively for pain related to needle insertion into a fistula in hemodialysis patients. Future research should investigate the comparative effects of pharmacological and non-pharmacological interventions on fistula puncture-related pain. Copyright © 2017 Elsevier Ltd. All rights reserved.
Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.
2014-01-01
This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N. PMID:25126446
Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S
2013-01-01
This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N.
Target-matched insertion gain derived from three different hearing aid selection procedures.
Punch, J L; Shovels, A H; Dickinson, W W; Calder, J H; Snead, C
1995-11-01
Three hearing aid selection procedures were compared to determine if any one was superior in producing prescribed real-ear insertion gain. For each of three subject groups, 12 in-the-ear style hearing aids with Class D circuitry and similar dispenser controls were ordered from one of three manufacturers. Subject groups were classified based on the type of information included on the hearing aid order form: (1) the subject's audiogram, (2) a three-part matrix specifying the desired maximum output, full-on gain, and frequency response slope of the hearing aid, or (3) the desired 2-cc coupler full-in grain of the hearing aid, based on real-ear coupler difference (RECD) measurements. Following electroacoustic adjustments aimed at approximating a commonly used target insertion gain formula, results revealed no significant differences among any of the three selection procedures with respect to obtaining acceptable insertion gain values.
NASA Technical Reports Server (NTRS)
Dahl, Roy W.; Keating, Karen; Salamone, Daryl J.; Levy, Laurence; Nag, Barindra; Sanborn, Joan A.
1987-01-01
This paper presents an algorithm (WHAMII) designed to solve the Artificial Intelligence Design Challenge at the 1987 AIAA Guidance, Navigation and Control Conference. The problem under consideration is a stochastic generalization of the traveling salesman problem in which travel costs can incur a penalty with a given probability. The variability in travel costs leads to a probability constraint with respect to violating the budget allocation. Given the small size of the problem (eleven cities), an approach is considered that combines partial tour enumeration with a heuristic city insertion procedure. For computational efficiency during both the enumeration and insertion procedures, precalculated binomial probabilities are used to determine an upper bound on the actual probability of violating the budget constraint for each tour. The actual probability is calculated for the final best tour, and additional insertions are attempted until the actual probability exceeds the bound.
Assessment of shock wave lithotripters via cavitation potential
Iloreta, Jonathan I.; Zhou, Yufeng; Sankin, Georgy N.; Zhong, Pei; Szeri, Andrew J.
2008-01-01
A method to characterize shock wave lithotripters by examining the potential for cavitation associated with the lithotripter shock wave (LSW) has been developed. The method uses the maximum radius achieved by a bubble subjected to a LSW as a representation of the cavitation potential for that region in the lithotripter. It is found that the maximum radius is determined by the work done on a bubble by the LSW. The method is used to characterize two reflectors: an ellipsoidal reflector and an ellipsoidal reflector with an insert. The results show that the use of an insert reduced the −6 dB volume (with respect to peak positive pressure) from 1.6 to 0.4 cm3, the −6 dB volume (with respect to peak negative pressure) from 14.5 to 8.3 cm3, and reduced the volume characterized by high cavitation potential (i.e., regions characterized by bubbles with radii larger than 429 µm) from 103 to 26 cm3. Thus, the insert is an effective way to localize the potentially damaging effects of shock wave lithotripsy, and suggests an approach to optimize the shape of the reflector. PMID:19865493
Crystallographic studies of the anthrax lethal toxin. Final report, 1 July 1994-31 December 1996
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frederick, C.A.
1997-01-01
Protective Antigen (PA) is the central component of the three-part protein toxin secreted by Bacillus anthraces, the organism responsible for anthrax. Following proteolytic activation on the host cell surface, PA forms a membrane-inserting heptamer that translocates the toxic enzymes into the cytosol. We have solved the crystal structure of monomeric PA at 2.1 A resolution and the water-soluble heptamer at 4.5 A resolution. The monomer is organized mainly into antiparallel b-sheets and has four domains: an N-terminal domain containing two calcium ions; a heptamerization domain containing a large flexible loop implicated in membrane insertion; a small domain of unknown function;more » and a C-terminal receptor-binding domain. Removal of a 20 kDa fragment from the N-terminal domain permits assembly of the heptamer, a ring-shaped structure with a negatively charged lumen, and exposes a large hydrophobic surface for binding the toxic enzymes. We present a model of pH-dependent membrane insertion involving formation of a porin-like membrane-spanning b barrel. These studies greatly enhance current understanding of the mechanism of anthrax intoxication, and will be useful in the design of recombinant anthrax vaccines.« less
Efficiency of vibrational sounding in parasitoid host location depends on substrate density.
Fischer, S; Samietz, J; Dorn, S
2003-10-01
Parasitoids of concealed hosts have to drill through a substrate with their ovipositor for successful parasitization. Hymenopteran species in this drill-and-sting guild locate immobile pupal hosts by vibrational sounding, i.e., echolocation on solid substrate. Although this host location strategy is assumed to be common among the Orussidae and Ichneumonidae there is no information yet whether it is adapted to characteristics of the host microhabitat. This study examined the effect of substrate density on responsiveness and host location efficiency in two pupal parasitoids, Pimpla turionellae and Xanthopimpla stemmator (Hymenoptera: Ichneumonidae), with different host-niche specialization and corresponding ovipositor morphology. Location and frequency of ovipositor insertions were scored on cylindrical plant stem models of various densities. Substrate density had a significant negative effect on responsiveness, number of ovipositor insertions, and host location precision in both species. The more niche-specific species X. stemmator showed a higher host location precision and insertion activity. We could show that vibrational sounding is obviously adapted to the host microhabitat of the parasitoid species using this host location strategy. We suggest the attenuation of pulses during vibrational sounding as the energetically costly limiting factor for this adaptation.
Time-elapsed screw insertion with microCT imaging.
Ryan, M K; Mohtar, A A; Cleek, T M; Reynolds, K J
2016-01-25
Time-elapsed analysis of bone is an innovative technique that uses sequential image data to analyze bone mechanics under a given loading regime. This paper presents the development of a novel device capable of performing step-wise screw insertion into excised bone specimens, within the microCT environment, whilst simultaneously recording insertion torque, compression under the screw head and rotation angle. The system is computer controlled and screw insertion is performed in incremental steps of insertion torque. A series of screw insertion tests to failure were performed (n=21) to establish a relationship between the torque at head contact and stripping torque (R(2)=0.89). The test-device was then used to perform step-wise screw insertion, stopping at intervals of 20%, 40%, 60% and 80% between screw head contact and screw stripping. Image data-sets were acquired at each of these time-points as well as at head contact and post-failure. Examination of the image data revealed the trabecular deformation as a result of increased insertion torque was restricted to within 1mm of the outer diameter of the screw thread. Minimal deformation occurred prior to the step between the 80% time-point and post-failure. The device presented has allowed, for the first time, visualization of the micro-mechanical response in the peri-implant bone with increased tightening torque. Further testing on more samples is expected to increase our understanding of the effects of increased tightening torque at the micro-structural level, and the failure mechanisms of trabeculae. Copyright © 2015 Elsevier Ltd. All rights reserved.
Franca, Juçara Ribeiro; Foureaux, Giselle; Fuscaldi, Leonardo Lima; Ribeiro, Tatiana Gomes; Rodrigues, Lívia Bomfim; Bravo, Renata; Castilho, Rachel Oliveira; Yoshida, Maria Irene; Cardoso, Valbert Nascimento; Fernandes, Simone Odília; Cronemberger, Sebastião; Ferreira, Anderson José; Faraco, André Augusto Gomes
2014-01-01
The purpose of the present study was to develop and assess a novel sustained-release drug delivery system of Bimatoprost (BIM). Chitosan polymeric inserts were prepared using the solvent casting method and characterized by swelling studies, infrared spectroscopy, differential scanning calorimetry, drug content, scanning electron microscopy and in vitro drug release. Biodistribution of 99mTc-BIM eye drops and 99mTc-BIM-loaded inserts, after ocular administration in Wistar rats, was accessed by ex vivo radiation counting. The inserts were evaluated for their therapeutic efficacy in glaucomatous Wistar rats. Glaucoma was induced by weekly intracameral injection of hyaluronic acid. BIM-loaded inserts (equivalent to 9.0 µg BIM) were administered once into conjunctival sac, after ocular hypertension confirmation. BIM eye drop was topically instilled in a second group of glaucomatous rats for 15 days days, while placebo inserts were administered once in a third group. An untreated glaucomatous group was used as control. Intraocular pressure (IOP) was monitored for four consecutive weeks after treatment began. At the end of the experiment, retinal ganglion cells and optic nerve head cupping were evaluated in the histological eye sections. Characterization results revealed that the drug physically interacted, but did not chemically react with the polymeric matrix. Inserts sustainedly released BIM in vitro during 8 hours. Biodistribution studies showed that the amount of 99mTc-BIM that remained in the eye was significantly lower after eye drop instillation than after chitosan insert implantation. BIM-loaded inserts lowered IOP for 4 weeks, after one application, while IOP values remained significantly high for the placebo and untreated groups. Eye drops were only effective during the daily treatment period. IOP results were reflected in RGC counting and optic nerve head cupping damage. BIM-loaded inserts provided sustained release of BIM and seem to be a promising system for glaucoma management. PMID:24788066
A. Dan Wilson; D.G. Lester
1999-01-01
Fourth-year field evaluations of four trench insert materials, including water-permeable Typar® polypropylene spunbonded fabric, Biobarrier® or Typar® with trifluralin-impregnated nodules, and water-impermeable polyethylene Geomembrane liners of two thicknesses (20 and 30 mil), were conducted to further test the effectiveness of these physical and/or chemical...
Negative electrodes for Na-ion batteries.
Dahbi, Mouad; Yabuuchi, Naoaki; Kubota, Kei; Tokiwa, Kazuyasu; Komaba, Shinichi
2014-08-07
Research interest in Na-ion batteries has increased rapidly because of the environmental friendliness of sodium compared to lithium. Throughout this Perspective paper, we report and review recent scientific advances in the field of negative electrode materials used for Na-ion batteries. This paper sheds light on negative electrode materials for Na-ion batteries: carbonaceous materials, oxides/phosphates (as sodium insertion materials), sodium alloy/compounds and so on. These electrode materials have different reaction mechanisms for electrochemical sodiation/desodiation processes. Moreover, not only sodiation-active materials but also binders, current collectors, electrolytes and electrode/electrolyte interphase and its stabilization are essential for long cycle life Na-ion batteries. This paper also addresses the prospect of Na-ion batteries as low-cost and long-life batteries with relatively high-energy density as their potential competitive edge over the commercialized Li-ion batteries.
NASA Astrophysics Data System (ADS)
Dotsenko, V. V.; Sahu, A.; Chonigman, B.; Tang, J.; Lehmann, A. E.; Gupta, V.; Talalevskii, A.; Ruotolo, S.; Sarwana, S.; Webber, R. J.; Gupta, D.
2017-02-01
Research and development of cryogenic application-specific integrated circuits (ASICs), such as high-frequency (tens of GHz) semiconductor and superconductor mixed-signal circuits and large-scale (>10,000 Josephson Junctions) superconductor digital circuits, have long been hindered by the absence of specialized cryogenic test apparatus. During their iterative development phase, most ASICs require many additional input-output lines for applying independent bias controls, injecting test signals, and monitoring outputs of different sub-circuits. We are developing a full suite of modular test apparatus based on cryocoolers that do not consume liquid helium, and support extensive electrical interfaces to standard and custom test equipment. Our design separates the cryogenics from electrical connections, allowing even inexperienced users to conduct testing by simply mounting their ASIC on a removable electrical insert. Thermal connections between the cold stages and the inserts are made with robust thermal links. ICE-T accommodates two independent electrical inserts at the same time. We have designed various inserts, such as universal ones with all 40 or 80 coaxial cables and those with customized wiring and temperature-controlled stages. ICE-T features fast thermal cycling for rapid testing, enables detailed testing over long periods (days to months, if necessary), and even supports automated testing of digital ICs with modular additions.
Dickson, J.J.
1958-07-01
A quick releasable mechanical drive system suitable for use in a nuclear reactor is described. A small reversible motor positions a control rod by means of a worm and gear speed reducer, a magnetic torque clutch, and a bell crank. As the control rod is raised to the operating position, a heavy coil spring is compressed. In the event of an emergency indicated by either a''scram'' signal or a power failure, the current to the magnetic clutch is cut off, thereby freeing the coil spring and the bell crank positioner from the motor and speed reduction gearing. The coil spring will immediately act upon the bell crank to cause the insertion of the control rod. This arrangement will allow the slow, accurate positioning of the control rod during reactor operation, while providing an independent force to rapidly insert the rod in the event of an emergency.
Nolden, T; Pfaff, F; Nemitz, S; Freuling, C M; Höper, D; Müller, T; Finke, Stefan
2016-04-05
Reverse genetics approaches are indispensable tools for proof of concepts in virus replication and pathogenesis. For negative strand RNA viruses (NSVs) the limited number of infectious cDNA clones represents a bottleneck as clones are often generated from cell culture adapted or attenuated viruses, with limited potential for pathogenesis research. We developed a system in which cDNA copies of complete NSV genomes were directly cloned into reverse genetics vectors by linear-to-linear RedE/T recombination. Rapid cloning of multiple rabies virus (RABV) full length genomes and identification of clones identical to field virus consensus sequence confirmed the approache's reliability. Recombinant viruses were recovered from field virus cDNA clones. Similar growth kinetics of parental and recombinant viruses, preservation of field virus characters in cell type specific replication and virulence in the mouse model were confirmed. Reduced titers after reporter gene insertion indicated that the low level of field virus replication is affected by gene insertions. The flexibility of the strategy was demonstrated by cloning multiple copies of an orthobunyavirus L genome segment. This important step in reverse genetics technology development opens novel avenues for the analysis of virus variability combined with phenotypical characterization of recombinant viruses at a clonal level.
Alternative Splicing of a Novel Inducible Exon Diversifies the CASK Guanylate Kinase Domain
Dembowski, Jill A.; An, Ping; Scoulos-Hanson, Maritsa; Yeo, Gene; Han, Joonhee; Fu, Xiang-Dong; Grabowski, Paula J.
2012-01-01
Alternative pre-mRNA splicing has a major impact on cellular functions and development with the potential to fine-tune cellular localization, posttranslational modification, interaction properties, and expression levels of cognate proteins. The plasticity of regulation sets the stage for cells to adjust the relative levels of spliced mRNA isoforms in response to stress or stimulation. As part of an exon profiling analysis of mouse cortical neurons stimulated with high KCl to induce membrane depolarization, we detected a previously unrecognized exon (E24a) of the CASK gene, which encodes for a conserved peptide insertion in the guanylate kinase interaction domain. Comparative sequence analysis shows that E24a appeared selectively in mammalian CASK genes as part of a >3,000 base pair intron insertion. We demonstrate that a combination of a naturally defective 5′ splice site and negative regulation by several splicing factors, including SC35 (SRSF2) and ASF/SF2 (SRSF1), drives E24a skipping in most cell types. However, this negative regulation is countered with an observed increase in E24a inclusion after neuronal stimulation and NMDA receptor signaling. Taken together, E24a is typically a skipped exon, which awakens during neuronal stimulation with the potential to diversify the protein interaction properties of the CASK polypeptide. PMID:23008758
Otsuka, Sachio; Saiki, Jun
2016-02-01
Prior studies have shown that visual statistical learning (VSL) enhances familiarity (a type of memory) of sequences. How do statistical regularities influence the processing of each triplet element and inserted distractors that disrupt the regularity? Given that increased attention to triplets induced by VSL and inhibition of unattended triplets, we predicted that VSL would promote memory for each triplet constituent, and degrade memory for inserted stimuli. Across the first two experiments, we found that objects from structured sequences were more likely to be remembered than objects from random sequences, and that letters (Experiment 1) or objects (Experiment 2) inserted into structured sequences were less likely to be remembered than those inserted into random sequences. In the subsequent two experiments, we examined an alternative account for our results, whereby the difference in memory for inserted items between structured and random conditions is due to individuation of items within random sequences. Our findings replicated even when control letters (Experiment 3A) or objects (Experiment 3B) were presented before or after, rather than inserted into, random sequences. Our findings suggest that statistical learning enhances memory for each item in a regular set and impairs memory for items that disrupt the regularity. Copyright © 2015 Elsevier B.V. All rights reserved.
Crandell, Douglas W.; Mazumder, Shivnath
2015-01-01
Density functional theory calculations demonstrate that the reversal of regiochemical outcome of the addition for substituted methyl propiolates in the rhodium-catalyzed [(2 + 2) + 2] carbocyclization with PPh3 and (S)-xyl-binap as ligands is both electronically and sterically controlled. For example, the ester functionality polarizes the alkyne π* orbital to favor overlap of the methyl-substituted terminus of the alkyne with the pπ-orbital of the alkenyl fragment of the rhodacycle during alkyne insertion with PPh3 as the ligand. In contrast, the sterically demanding xyl-binap ligand cannot accommodate the analogous alkyne orientation, thereby forcing insertion to occur at the sterically preferred ester terminus, overriding the electronically preferred orientation for alkyne insertion. PMID:28757978
Apparatus and method of inserting a microelectrode in body tissue or the like using vibration means
NASA Technical Reports Server (NTRS)
Feldstein, C.; Crawford, D. W.; Kanabus, E. W. (Inventor)
1979-01-01
An arrangement for and method of inserting a glass microelectrode having a tip in the micron range into body tissue is presented. The arrangement includes a microelectrode. The top of the microelectrode is attached to the diaphragm center of a first speaker. The microelectrode tip is brought into contact with the tissue by controlling a micromanipulator. Thereafter, an audio signal is applied to the speaker to cause the microelectrode to vibrate and thereby pierce the tissue surface without breaking the microelectrode tip. Thereafter, the tip is inserted into the tissue to the desired depth by operating the micromanipulator with the microelectrode in a vibratory or non-vibratory state.
Solar Cell Modules With Improved Backskin
Chevrefils, Andre; Grigore, Daniel Gheorghe
2001-01-23
The present invention relates to gas turbines and more particularly to a device for controlling the flow of cooling air through a flowpath in a turbine blade. The device can be inserted in the inlet opening of the blade flowpath and be retained therein. The device comprises a plug member for adjusting the flow of cooling air through the flowpath. The plug member comprises a retaining portion for retaining the plug member at the inlet opening of the flowpath and a blocking portion inserted within the flowpath for reducing the cross-sectional area of the inlet opening. Such a device is inexpensive and can be easily inserted in the inlet opening of a blade flowpath and retained therein.
Development of a Hard X-ray Beam Position Monitor for Insertion Device Beams at the APS
NASA Astrophysics Data System (ADS)
Decker, Glenn; Rosenbaum, Gerd; Singh, Om
2006-11-01
Long-term pointing stability requirements at the Advanced Photon Source (APS) are very stringent, at the level of 500 nanoradians peak-to-peak or better over a one-week time frame. Conventional rf beam position monitors (BPMs) close to the insertion device source points are incapable of assuring this level of stability, owing to mechanical, thermal, and electronic stability limitations. Insertion device gap-dependent systematic errors associated with the present ultraviolet photon beam position monitors similarly limit their ability to control long-term pointing stability. We report on the development of a new BPM design sensitive only to hard x-rays. Early experimental results will be presented.
Transposon tagging of genes for cell-cell interactions in Myxococcus xanthus.
Kalos, M; Zissler, J
1990-01-01
The prokaryote Myxococcus xanthus is a model for cell interactions important in multicellular behavior. We used the transposon TnphoA to specifically identify genes for cell-surface factors involved in cell interactions. From a library of 10,700 insertions of TnphoA, we isolated 36 that produced alkaline phosphatase activity. Three TnphoA insertions tagged cell motility genes, called cgl, which control the adventurous movement of cells. The products of the tagged cgl genes could function in trans upon other cells and were localized primarily in the cell envelope and extracellular space, consistent with TnphoA tagging genes for extracellular factors controlling motility. Images PMID:2172982
2011-01-01
Background We describe the rationale and protocol for a randomized controlled trial (RCT) to assess whether intrauterine contraception placed immediately after a second trimester abortion will result in fewer pregnancies than current recommended practice of intended placement at 4 weeks post-abortion. Decision analysis suggests the novel strategy could substantially reduce subsequent unintended pregnancies and abortions. This paper highlights considerations of design, implementation and evaluation of a trial expected to provide rigorous evidence for appropriate insertion timing and health economics of intrauterine contraception after second trimester abortion. Methods/Design Consenting women choosing to use intrauterine contraception after abortion for a pregnancy of 12 to 24 weeks will be randomized to insertion timing groups either immediately (experimental intervention) or four weeks (recommended care) post abortion. Primary outcome measure is pregnancy rate at one year. Secondary outcomes include: cumulative pregnancy rates over five year follow-up period, comprehensive health economic analyses comparing immediate and delayed insertion groups, and device retention rates, complication rates (infection, expulsion) and, contraceptive method satisfaction. Web-based Contraception Satisfaction Questionnaires, clinical records and British Columbia linked health databases will be used to assess primary and secondary outcomes. Enrolment at all clinics in the province performing second trimester abortions began in May 2010 and is expected to complete in late 2011. Data on one year outcomes will be available for analysis in 2014. Discussion The RCT design combined with access to clinical records at all provincial abortion clinics, and to information in provincial single-payer linked administrative health databases, birth registry and hospital records, offers a unique opportunity to evaluate such an approach by determining pregnancy rate at one through five years among enrolled women. We highlight considerations of design, implementation and evaluation of a trial expected to provide rigorous evidence for appropriate insertion timing and health economics of intrauterine contraception after second trimester abortion. Trial registration Current Controlled Trials ISRCTN19506752 PMID:21672213
48 CFR 970.5203-1 - Management controls.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Management controls. 970... for Management and Operating Contracts 970.5203-1 Management controls. As prescribed in 970.0370-2(a) and 970.3270(a)(4), insert the following clause: Management Controls (JUN 2007) (a)(1) The Contractor...
48 CFR 970.5203-1 - Management controls.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Management controls. 970... for Management and Operating Contracts 970.5203-1 Management controls. As prescribed in 970.0370-2(a) and 970.3270(a)(4), insert the following clause: Management Controls (JUN 2007) (a)(1) The Contractor...
48 CFR 970.5203-1 - Management controls.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Management controls. 970... for Management and Operating Contracts 970.5203-1 Management controls. As prescribed in 970.0370-2(a) and 970.3270(a)(4), insert the following clause: Management Controls (JUN 2007) (a)(1) The Contractor...
48 CFR 970.5203-1 - Management controls.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Management controls. 970... for Management and Operating Contracts 970.5203-1 Management controls. As prescribed in 970.0370-2(a) and 970.3270(a)(4), insert the following clause: Management Controls (JUN 2007) (a)(1) The Contractor...
da Silva, Adriana Valerio; de Melo, Anderson Sanches; Barboza, Rebecca Pontelo; de Paula Martins, Wellington; Ferriani, Rui Alberto; Vieira, Carolina Sales
2016-07-01
Polycystic ovary syndrome (PCOS) is related to clinical and metabolic comorbidities that may limit the prescription of combined hormonal contraceptives, with consequent need to use progestogen-only contraceptives (POCs). Thus, the objective of the present study was to evaluate the clinical and metabolic effects of a POC, the levonorgestrel-releasing intrauterine system (LNG-IUS), in women with PCOS followed up over a period of 6 months compared to baseline and to women without PCOS. Thus, an observational, prospective, controlled study was conducted on 30 women with a diagnosis of PCOS who presented adverse effect secondary to the use of combined oral contraceptives (nausea, headache, mastalgia or vomiting; PCOS group) paired with 30 ovulatory women without PCOS (control group), both groups being free of comorbidities and having chosen the LNG-IUS as contraceptive. Clinical, laboratory, and ultrasonographic variables were evaluated immediately before LNG-IUS insertion and 6 months after the use of this method. Before LNG-IUS insertion, the PCOS group had higher total testosterone levels (P = .04), lower HDL levels (P = .04), and greater ovarian volume (P < .01) than the control group. Six months after LNG-IUS insertion, there was a 2.3% increase in abdominal circumference (P = .04) and a 3.4% increase in fasting glycemia (P = .02). On the other hand, mean ovarian volume was 10% smaller compared to the volume found before LNG-IUS insertion (P = .04), LDL levels were reduced by 5.2% (P = .03), and total cholesterol levels were reduced by 6.7% (P < .01) compared to baseline evaluation in the PCOS group. The remaining variables did not differ significantly during the 6 months of observation. The control group did not show significant changes compared to the period before LNG-IUS insertion. When the groups were compared after the 6-month follow-up, only glycemia showed a statistically significant variation between the groups, with glycemia levels increasing by 3.4% in the PCOS group and decreasing by 2.6% in the control group (P = .008). In conclusion, the use of the LNG-IUS for 6 months was not associated with relevant changes in clinical or metabolic variables of women with no comorbidities regardless of the presence of PCOS. © The Author(s) 2016.
Kong, Xiangxue; Tang, Lei; Ye, Qiang; Huang, Wenhua; Li, Jianyi
2017-11-01
Accurate and safe posterior thoracic pedicle insertion (PTPI) remains a challenge. Patient-specific drill templates (PDTs) created by rapid prototyping (RP) can assist in posterior thoracic pedicle insertion, but pose biocompatibility risks. The aims of this study were to develop alternative PDTs with computer numerical control (CNC) and assess their feasibility and accuracy in assisting PTPI. Preoperative CT images of 31 cadaveric thoracic vertebras were obtained and then the optimal pedicle screw trajectories were planned. The PDTs with optimal screw trajectories were randomly assigned to be designed and manufactured by CNC or RP in each vertebra. With the guide of the CNC- or RP-manufactured PDTs, the appropriate screws were inserted into the pedicles. Postoperative CT scans were performed to analyze any deviations at entry point and midpoint of the pedicles. The CNC group was found to be significant manufacture-time-shortening, and cost-decreasing, when compared with the RP group (P < 0.01). The PDTs fitted the vertebral laminates well while all screws were being inserted into the pedicles. There were no significant differences in absolute deviations at entry point and midpoint of the pedicle on either axial or sagittal planes (P > 0.05). The screw positions were grade 0 in 90.3% and grade 1 in 9.7% of the cases in the CNC group and grade 0 in 93.5% and grade 1 in 6.5% of the cases in the RP group (P = 0.641). CNC-manufactured PDTs are viable for assisting in PTPI with good feasibility and accuracy.
Fonseca, Cátia; Planchon, Sébastien; Serra, Tânia; Chander, Subhash; Saibo, Nelson J M; Renaut, Jenny; Oliveira, M Margarida; Batista, Rita
2015-01-01
Identification of differences between genetically modified plants and their original counterparts plays a central role in risk assessment strategy. Our main goal was to better understand the relevance of transgene presence, genetic, and epigenetic changes induced by transgene insertion, and in vitro culture in putative unintended differences between a transgenic and its comparator. Thus, we have used multiplex fluorescence 2DE coupled with MS to characterize the proteome of three different rice lines (Oryza sativa L. ssp. japonica cv. Nipponbare): a control conventional line (C), an Agrobacterium-transformed transgenic line (Ta) and a negative segregant (NSb). We observed that Ta and NSb appeared identical (with only one spot differentially abundant--fold difference ≥ 1.5), contrasting with the control (49 spots with fold difference ≥ 1.5, in both Ta and NSb vs. control). Given that in vitro culture was the only event in common between Ta and NSb, we hypothesize that in vitro culture stress was the most relevant condition contributing for the observed proteomic differences. MS protein identification support our hypothesis, indicating that Ta and NSb lines adjusted their metabolic pathways and altered the abundance of several stress related proteins in order to cope with in vitro culture. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Prevention of tuberculosis in rhesus macaques by a cytomegalovirus-based vaccine.
Hansen, Scott G; Zak, Daniel E; Xu, Guangwu; Ford, Julia C; Marshall, Emily E; Malouli, Daniel; Gilbride, Roxanne M; Hughes, Colette M; Ventura, Abigail B; Ainslie, Emily; Randall, Kurt T; Selseth, Andrea N; Rundstrom, Parker; Herlache, Lauren; Lewis, Matthew S; Park, Haesun; Planer, Shannon L; Turner, John M; Fischer, Miranda; Armstrong, Christina; Zweig, Robert C; Valvo, Joseph; Braun, Jackie M; Shankar, Smitha; Lu, Lenette; Sylwester, Andrew W; Legasse, Alfred W; Messerle, Martin; Jarvis, Michael A; Amon, Lynn M; Aderem, Alan; Alter, Galit; Laddy, Dominick J; Stone, Michele; Bonavia, Aurelio; Evans, Thomas G; Axthelm, Michael K; Früh, Klaus; Edlefsen, Paul T; Picker, Louis J
2018-02-01
Despite widespread use of the bacille Calmette-Guérin (BCG) vaccine, tuberculosis (TB) remains a leading cause of global mortality from a single infectious agent (Mycobacterium tuberculosis or Mtb). Here, over two independent Mtb challenge studies, we demonstrate that subcutaneous vaccination of rhesus macaques (RMs) with rhesus cytomegalovirus vectors encoding Mtb antigen inserts (hereafter referred to as RhCMV/TB)-which elicit and maintain highly effector-differentiated, circulating and tissue-resident Mtb-specific CD4 + and CD8 + memory T cell responses-can reduce the overall (pulmonary and extrapulmonary) extent of Mtb infection and disease by 68%, as compared to that in unvaccinated controls, after intrabronchial challenge with the Erdman strain of Mtb at ∼1 year after the first vaccination. Fourteen of 34 RhCMV/TB-vaccinated RMs (41%) across both studies showed no TB disease by computed tomography scans or at necropsy after challenge (as compared to 0 of 17 unvaccinated controls), and ten of these RMs were Mtb-culture-negative for all tissues, an exceptional long-term vaccine effect in the RM challenge model with the Erdman strain of Mtb. These results suggest that complete vaccine-mediated immune control of highly pathogenic Mtb is possible if immune effector responses can intercept Mtb infection at its earliest stages.
Sensor Life and Overnight Closed Loop: A Randomized Clinical Trial.
Tauschmann, Martin; Allen, Janet M; Wilinska, Malgorzata E; Ruan, Yue; Thabit, Hood; Acerini, Carlo L; Dunger, David B; Hovorka, Roman
2017-05-01
Closed-loop (CL) systems direct insulin delivery based on continuous glucose monitor (CGM) sensor values. CGM accuracy varies with sensor life, being least accurate on day 1 of sensor insertion. We evaluated the effect of sensor life (enhanced Enlite, Medtronic MiniMed, Northridge, CA) on overnight CL. In an open-label, randomized, 2-period, inpatient crossover pilot study, 12 adolescents on insulin pump (age 16.7 ± 1.9 years; HbA1c 66 ± 10 mmol/mol) attended a clinical research facility on 2 overnight occasions. In random order, participants received CL on day 1 or on day 3-4 after sensor insertion. During both periods, glucose was automatically controlled by a model predictive control algorithm informed by sensor glucose. Plasma glucose was measured every 30 to 60 min. During overnight CL (22:30 to 07:30), the proportion of time with plasma glucose readings in the target range (3.9-8.0 mmol/l, primary endpoint) when initiated on day 1 of sensor insertion vs day 3-4 were comparable (58 ± 32% day 1 vs 56 ± 36% day 3-4; P = .34), and there were no significant differences between interventions in terms of mean plasma glucose ( P = .26), percentage time above 8.0 mmol/l ( P = .49), and time spent below 3.9 mmol/l ( P = .93). Sensor accuracy varied with sensor life (mean absolute relative difference 19.8 ± 15.0% on day 1 and 13.7 ± 10.2% on day 3 to 4). Sensor glucose tended to under-read plasma glucose inflating benefits of CL on glucose control. In spite of differences in sensor accuracy, overnight CL glucose control informed by sensor glucose on day 1 or day 3-4 after sensor insertion was comparable. The model predictive controller appears to mitigate against sensor inaccuracies.
Dixon, A B; Knights, M; Pate, J L; Lewis, P E; Inskeep, E K
2006-04-01
Three experiments were conducted with a total of 1579 ewes to examine reproductive performance in response to synchronization of oestrus during the breeding season, using controlled internal drug releasing (CIDR-G) inserts in regimens designed to provide high concentrations of circulating progesterone. In experiment 1, treatment with two CIDR-G inserts for 12 days produced conception rate (79%) and prolificacy (1.9) to first service equivalent to breeding at natural oestrus (56% and 2.0, respectively). Pregnancy rates to two service periods were 90 and 79%, respectively. In experiments 2 and 3, progesterone was delivered by a single CIDR-G insert for 5 days in combination with prostaglandin F2alpha (PGF2alpha; 5 mg i.m., twice, 3 h apart) the day before (experiment 2), or at insert removal (experiment 3). The combined treatments improved rates of synchronization of oestrus (p<0.01) by 23 and 20% points, respectively, and pregnancy rates to the first service period by 19 (p<0.05) and 13 (p<0.01) percentage points, respectively, compared to treatment with PGF2alpha alone. It is concluded that the combination of treatment for 5 days with a CIDR-G insert and two injections of 5 mg PGF2alpha, the day before, or the day of insert removal, were effective treatments to obtain high fertility at synchronized oestrus in ewes during the breeding season.
New Approach to Image Aerogels by Scanning Electron Microscopy
NASA Astrophysics Data System (ADS)
Solá, Francisco; Hurwitz, Frances; Yang, Jijing
2011-03-01
A new scanning electron microscopy (SEM) technique to image poor electrically conductive aerogels is presented. The process can be performed by non-expert SEM users. We showed that negative charging effects on aerogels can be minimized significantly by inserting dry nitrogen gas close to the region of interest. The process involves the local recombination of accumulated negative charges with positive ions generated from ionization processes. This new technique made possible the acquisition of images of aerogels with pores down to approximately 3nm in diameter using a positively biased Everhart-Thornley (E-T) detector. Well-founded concepts based on known models will also be presented with the aim to explain the results qualitatively.
Amundsen, Spencer; Lee, Yuo-Yu; González Della Valle, Alejandro
2017-06-01
Intra-operative sensing technology is an alternative to standard techniques in total knee arthroplasty (TKA) for determining balance by providing quantitative analysis of loads and point of contact throughout a range of motion. We used intra-operative sensing (VERASENSE-OrthoSensor, Inc.) to examine pie-crusting release of the medial collateral ligament in knees with varus deformity (study group) in comparison to a control group where balance was obtained using a classic release technique and assessed using laminar spreaders, spacer blocks, manual stress, and a ruler. The surgery was performed by a single surgeon utilizing measured resection and posterior-stabilized, cemented implants. Seventy-five study TKAs were matched 1:3 with 225 control TKAs. Outcome variables included the use of a constrained insert, functional- and knee-specific Knee Society score (KSS) at six weeks, four months, and one year post-operatively. Outcomes were analyzed in a multivariate model controlling for age, sex, BMI, and severity of deformity. The use of a constrained insert was significantly lower in the study group (5.3 vs. 13.8%; p = 0.049). The use of increased constraint was not significant between groups with increasing deformity. There was no difference in functional KSS and knee-specific KSS between groups at any follow-up interval. An algorithmic pie-crusting technique guided by intra-operative sensing is associated with decreased use of constrained inserts in TKA patients with a pre-operative varus deformity. This may cause a positive shift in value and cost savings.
Coastal Acoustic Tomography Data Constraints Applied to a Coastal Ocean Circulation Model
1994-04-01
Postgraduate School Monterey, CA 93943-5100 Abstract A direct insertion scheme for assimilating coastal acoustic tomo- graphic ( CAT ) vertical...days of this control run were taken to represent "actuality." A series of assimilation experiments was carried out in which CAT temperature slices...synthesized from different CAT configurations based on the "true ocean" were inserted into the n.odel at various time steps to examine the convergence of
DOE Office of Scientific and Technical Information (OSTI.GOV)
Omel`yanchuk, L.V.
1995-12-01
A lethal insertion of an element P[lArB], which caused nondisjunction and structural abnormalities in chromosomes in the neuroblasts of homozygous larvae, was found. The insertion was mapped to region 57B1-12 of the polytene map of chromosome 2 of Drosophila. The expression of the corresponding gene was found in testes, ovaries, and neural ganglia. 8 refs., 6 figs.
Pelloux, Sophie; Grégoire, Arnaud; Kirmizigul, Patrice; Maillot, Sandrine; Bui-Xuan, Bernard; Llorca, Guy; Boet, Sylvain; Lehot, Jean-Jacques; Rimmelé, Thomas
2017-12-01
Peripheral venous catheter insertion is a procedural skill that every medical student should master. Training is often limited to a small number of students and is poorly evaluated. The objective of this study was to evaluate the performance of peer-assisted learning in comparison to instructor-led teaching for peripheral venous catheter insertion training. Students were randomized to the control group attending a traditional instructor-led training session (slideshow and demonstration by an anesthetist instructor, followed by training on a procedural simulator) or to the test group attending a peer-assisted training session (slideshow and demonstration video-recorded by the same instructor, followed by training on a procedural simulator). The primary endpoint was the performance of peripheral venous catheter insertion, assessed on procedural simulator one week later by blinded experts using a standardized 20-item grid. Students self-evaluated their confidence levels using a numeric 10-point scale. Eighty-six students were included, 73 of whom attended the assessment session. The median performance score was 12/20 [8-15] in the instructor-led teaching group versus 13/20 [11-15] in the peer-assisted learning group (P=0.430). Confidence levels improved significantly after the assessment session and were significantly higher in the peer-assisted learning group (7.6/10 [7.0-8.0] versus 7.0/10 [5.0-8.0], P=0.026). Peer-assisted learning is effective for peripheral venous catheter insertion training and can be as effective as instructor-led teaching. Given the large number of students to train, this finding is important for optimizing the cost-effectiveness of peripheral venous catheter insertion training. Copyright © 2017 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.
Zhu, Hongwen; Shang, Dandan; Sun, Miao; Choi, Sunju; Liu, Qing; Hao, Jiajie; Figuera, Luis E.; Zhang, Feng; Choy, Kwong Wai; Ao, Yang; Liu, Yang; Zhang, Xiao-Lin; Yue, Fengzhen; Wang, Ming-Rong; Jin, Li; Patel, Pragna I.; Jing, Tao; Zhang, Xue
2011-01-01
X-linked congenital generalized hypertrichosis (CGH), an extremely rare condition characterized by universal overgrowth of terminal hair, was first mapped to chromosome Xq24-q27.1 in a Mexican family. However, the underlying genetic defect remains unknown. We ascertained a large Chinese family with an X-linked congenital hypertrichosis syndrome combining CGH, scoliosis, and spina bifida and mapped the disease locus to a 5.6 Mb critical region within the interval defined by the previously reported Mexican family. Through the combination of a high-resolution copy-number variation (CNV) scan and targeted genomic sequencing, we identified an interchromosomal insertion at Xq27.1 of a 125,577 bp intragenic fragment of COL23A1 on 5q35.3, with one X breakpoint within and the other very close to a human-specific short palindromic sequence located 82 kb downstream of SOX3. In the Mexican family, we found an interchromosomal insertion at the same Xq27.1 site of a 300,036 bp genomic fragment on 4q31.2, encompassing PRMT10 and TMEM184C and involving parts of ARHGAP10 and EDNRA. Notably, both of the two X breakpoints were within the short palindrome. The two palindrome-mediated insertions fully segregate with the CGH phenotype in each of the families, and the CNV gains of the respective autosomal genomic segments are not present in the public database and were not found in 1274 control individuals. Analysis of control individuals revealed deletions ranging from 173 bp to 9104 bp at the site of the insertions with no phenotypic consequence. Taken together, our results strongly support the pathogenicity of the identified insertions and establish X-linked congenital hypertrichosis syndrome as a genomic disorder. PMID:21636067
Mishima, Eriko; Sato, Yoko; Nanatani, Kei; Hoshi, Naomi; Lee, Jong-Kook; Schiller, Nina; von Heijne, Gunnar; Sakaguchi, Masao; Uozumi, Nobuyuki
2016-12-01
Voltage-dependent K + (K V ) channels control K + permeability in response to shifts in the membrane potential. Voltage sensing in K V channels is mediated by the positively charged transmembrane domain S4. The best-characterized K V channel, KvAP, lacks the distinct hydrophilic region corresponding to the S3-S4 extracellular loop that is found in other K + channels. In the present study, we evaluated the topogenic properties of the transmembrane regions within the voltage-sensing domain in KvAP. S3 had low membrane insertion activity, whereas S4 possessed a unique type-I signal anchor (SA-I) function, which enabled it to insert into the membrane by itself. S4 was also found to function as a stop-transfer signal for retention in the membrane. The length and structural nature of the extracellular S3-S4 loop affected the membrane insertion of S3 and S4, suggesting that S3 membrane insertion was dependent on S4. Replacement of charged residues within the transmembrane regions with residues of opposite charge revealed that Asp 72 in S2 and Glu 93 in S3 contributed to membrane insertion of S3 and S4, and increased the stability of S4 in the membrane. These results indicate that the SA-I function of S4, unique among K + channels studied to date, promotes the insertion of S3 into the membrane, and that the charged residues essential for voltage sensing contribute to the membrane-insertion of the voltage sensor domain in KvAP. © 2016 The Author(s); published by Portland Press Limited on behalf of the Biochemical Society.
Integral throat entrance development, qualification and production for the Antares 3 nozzle
NASA Technical Reports Server (NTRS)
Clayton, F. I.; Dirling, R. B.; Eitman, D. A.; Loomis, W. C.
1982-01-01
Although design analyses of a G-90 graphite integral throat entrance for the Antares 3 solid rocket motor nozzle indicated acceptable margins of safety, the nozzle throat insert suffered a thermostructural failure during the first development firing. Subsequent re-analysis using properties measured on material from the same billet as the nozzle throat insert showed negative margins. Carbon-carbon was investigated and found to result in large positive margins of safety. The G-90 graphite was replaced by SAI fast processed 4-D material which uses Hercules HM 10000 fiber as the reinforcement. Its construction allows powder filling of the interstices after preform fabrication which accelerates the densification process. Allied 15V coal tar pitch is then used to complete densification. The properties were extensively characterized on this material and six nozzles were subjected to demonstration, development and qualification firings.
Effects of high Z probe on plasma behavior in HT-6M tokamak
NASA Astrophysics Data System (ADS)
Li, J.; Gong, X.; Luo, L.; Yin, F. X.; Noda, N.; Wan, B.; Xu, W.; Gao, X.; Yin, F.; Jiang, J. G.; Wu, Z.; Zhao, J. Y.; Wu, M.; Liu, S.; Han, Y.
1997-02-01
Molybdenum and tungsten probes have been tested in HT-6M tokamak under various discharge conditions aiming to find out the conditions in which high Z PFC can be used without serious degradation of core plasma performance. In normal OH discharges, the degradation of core plasma performance was found only when the probe was inserted beyond 3.0 cm inside the last closed flux surface (LCFS). The plasma performance did not change with positive biasing to the probe, whereas central Te degraded during negative biasing of -100 V. The insertion of the Mo probe to 1.5 cm inside the LCFS made a change in the threshold power of the L-H transition in EOH discharges. These results suggest a certain operation range of the H-mode in the EOH discharge with the Mo probe in HT-6M.
High efficiency and enhanced ESD properties of UV LEDs by inserting p-GaN/p-AlGaN superlattice
NASA Astrophysics Data System (ADS)
Huang, Yong; Li, PeiXian; Yang, Zhuo; Hao, Yue; Wang, XiaoBo
2014-05-01
Significantly improved electrostatic discharge (ESD) properties of InGaN/GaN-based UV light-emitting diode (LED) with inserting p-GaN/p-AlGaN superlattice (p-SLs) layers (instead of p-AlGaN single layer) between multiple quantum wells and Mg-doped GaN layer are reported. The pass yield of the LEDs increased from 73.53% to 93.81% under negative 2000 V ESD pulses. In addition, the light output power (LOP) and efficiency droop at high injection current were also improved. The mechanism of the enhanced ESD properties was then investigated. After excluding the effect of capacitance modulation, high-resolution X-ray diffraction (XRD) and atomic force microscope (AFM) measurements demonstrated that the dominant mechanism of the enhanced ESD properties is the material quality improved by p-SLs, which indicated less leakage paths, rather than the current spreading improved by p-SLs.
Role versatility among men who have sex with men in urban Peru.
Goodreau, Steven M; Peinado, Jesus; Goicochea, Pedro; Vergara, Jorge; Ojeda, Nora; Casapia, Martin; Ortiz, Abner; Zamalloa, Victoria; Galvan, Rosa; Sanchez, Jorge R
2007-08-01
Role versatility refers to the practice in which individual men who have sex with men (MSM) play both insertive and receptive sexual roles over time. Versatility has been thought to be relatively uncommon among Latin American MSM but possibly rising. Versatility has also been shown to be a potentially large population-level risk factor for HIV infection. In this study we examine the correlates of versatile behavior and identity among 2,655 MSM in six Peruvian cities. Versatile behavior with recent male partners was found in 9% of men and versatile ("moderno") identity was reported by 16%. Significant predictors included high education, white-collar occupation, sex work, and residence in Lima. Age was not significant in any analysis. Since sex work is negatively correlated with other predictors, versatile men appear to comprise two distinct sub-populations. Insertive-only men appear to play a strong role in bridging the HIV epidemic between MSM and women.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-10
... Boilers and Process Heaters at Petroleum Refineries Correction In rule document 2010-13377 beginning on... limitations for Control [Insert page number any industrial boiler or Requirements. where the document process...
The Effectiveness of Acupuncture for Chronic Daily Headache: An Outcomes Study
2009-12-01
1107 -t- 3 chan- nel transcutaneous electrical nerve stimulator ( TENS ) units. The negative or black lead was clipped onto the needle in.serted at...arc easily accessible for electrical tonification, especially for acupuncture naive subjects. They can also be used during an acute headache episode...ache, warmth, tingling, pressure, or radiation). Mild electrical tonification was applied to the 2 acu- puncture needles in tbe foot, using an ITO-IC
Matičič, Mojca; Klavs, Irena; Videčnik Zorman, Jerneja; Vidmar Vovko, Darja; Kogoj, Rok; Keše, Darja
2016-01-01
A laboratory-confirmed lymphogranuloma venereum (LGV) case in Slovenia was reported in 2015, in a human immunodeficiency virus (HIV)-negative man presenting with inguinal lymphadenopathy. He reported unprotected insertive anal intercourse with two male partners in Croatia. Variant L2c of Chlamydia trachomatis was detected in clinical samples. Although the patient was eventually cured, the recommended treatment regimen with doxycycline had to be prolonged.
Insert Design and Manufacturing for Foam-Core Composite Sandwich Structures
NASA Astrophysics Data System (ADS)
Lares, Alan
Sandwich structures have been used in the aerospace industry for many years. The high strength to weight ratios that are possible with sandwich constructions makes them desirable for airframe applications. While sandwich structures are effective at handling distributed loads such as aerodynamic forces, they are prone to damage from concentrated loads at joints or due to impact. This is due to the relatively thin face-sheets and soft core materials typically found in sandwich structures. Carleton University's Uninhabited Aerial Vehicle (UAV) Project Team has designed and manufactured a UAV (GeoSury II Prototype) which features an all composite sandwich structure fuselage structure. The purpose of the aircraft is to conduct geomagnetic surveys. The GeoSury II Prototype serves as the test bed for many areas of research in advancing UAV technologies. Those areas of research include: low cost composite materials manufacturing, geomagnetic data acquisition, obstacle detection, autonomous operations and magnetic signature control. In this thesis work a methodology for designing and manufacturing inserts for foam-core sandwich structures was developed. The results of this research work enables a designer wishing to design a foam-core sandwich airframe structure, a means of quickly manufacturing optimized inserts for the safe introduction of discrete loads into the airframe. The previous GeoSury II Prototype insert designs (v.1 & v.2) were performance tested to establish a benchmark with which to compare future insert designs. Several designs and materials were considered for the new v.3 inserts. A plug and sleeve design was selected, due to its ability to effectively transfer the required loads to the sandwich structure. The insert material was chosen to be epoxy, reinforced with chopped carbon fibre. This material was chosen for its combination of strength, low mass and also compatibility with the face-sheet material. The v.3 insert assembly is 60% lighter than the previous insert designs. A casting process for manufacturing the v.3 inserts was developed. The developed casting process, when producing more than 13 inserts, becomes more economical than machining. An exploratory study was conducted looking at the effects of dynamic loading on the v.3 insert performance. The results of this study highlighted areas for improving dynamic testing of foam-core sandwich structure inserts. Correlations were developed relating design variables such as face-sheet thickness and insert diameter to a failure load for different load cases. This was done through simulations using Computer Aided Engineering (CAE) software, and experimental testing. The resulting correlations were integrated into a computer program which outputs the required insert dimensions given a set of design parameters, and load values.
Climate matching: implications for the biological control of hemlock woolly adelgid
R. Talbot III Trotter
2008-01-01
Classical biological control programs are faced with a daunting challenge: inserting a new species into an existing ecological system. In order for the newly introduced biological control species to survive and reproduce, the recipient ecosystem must provide the required biotic and abiotic requirements. The Adelgid Biological Control simulator (ABCs), a simulation...
Integrated Tools for Future Distributed Engine Control Technologies
NASA Technical Reports Server (NTRS)
Culley, Dennis; Thomas, Randy; Saus, Joseph
2013-01-01
Turbine engines are highly complex mechanical systems that are becoming increasingly dependent on control technologies to achieve system performance and safety metrics. However, the contribution of controls to these measurable system objectives is difficult to quantify due to a lack of tools capable of informing the decision makers. This shortcoming hinders technology insertion in the engine design process. NASA Glenn Research Center is developing a Hardware-inthe- Loop (HIL) platform and analysis tool set that will serve as a focal point for new control technologies, especially those related to the hardware development and integration of distributed engine control. The HIL platform is intended to enable rapid and detailed evaluation of new engine control applications, from conceptual design through hardware development, in order to quantify their impact on engine systems. This paper discusses the complex interactions of the control system, within the context of the larger engine system, and how new control technologies are changing that paradigm. The conceptual design of the new HIL platform is then described as a primary tool to address those interactions and how it will help feed the insertion of new technologies into future engine systems.
The Direct Insertion of the ACL Carries More Load than the Indirect Insertion
Nawabi, Danyal H.; Tucker, Scott; Jones, Kristofer J.; Nguyen, Joseph; Wickiewicz, Thomas L.; Imhauser, Carl; Pearle, Andrew
2014-01-01
Objectives: Recent histological studies have shown that the ACL consists of two different structures: the direct and indirect insertions. The direct insertion is located along the lateral intercondylar ridge and the indirect insertion is ‘lower’ in the notch, adjacent to the posterior articular cartilage. The ‘lower’ position has become more popular for locating the femoral tunnel, as surgeons switch to the anteromedial (AM) portal drilling technique in order to place the graft in the region of the native footprint. However, a recent registry-based outcomes study has reported a 1.5 times higher graft failure rate for AM portal versus traditional transtibial techniques. The objective of this study was to investigate the load characteristics of the native ACL in the regions of the direct and indirect insertions. We hypothesized that the direct insertion would carry more load than the indirect insertion. Methods: Twelve cadaveric knees were mounted to a six degree of freedom robot equipped with a universal force-moment sensor. We simulated the Lachman and anterior drawer tests at 30oand 90o of flexion by applying a 134N anterior load, and the pivot shift test at 15o flexion by applying combined valgus (8Nm) and internal (4Nm) rotational moments. The kinematic pathway required to achieve these loading conditions was recorded for each intact knee. Using position control to repeat the loading paths, the robot recorded the loads for the ACL intact, ACL partially sectioned, and ACL completely sectioned states. Sectioning Protocol: The lateral intercondylar ridge and posterior articular margin was identified in each case. The 50% mark between this two areas was used to delineate the regions of the direct and indirect insertions (Fig. 1). Sectioning order was alternated between each cadaver. Footprint Digitization: The borders of the sectioned areas were digitized post-sectioning and mapped onto a computed tomography (CT) scan of each knee. The sectioning method was assessed under a blinded validation by experienced observers (TW, AP) who excluded two specimens that did not conform to the objective definitions of the sectioning method. Statistics: Loads were compared between direct and indirect locations at different flexion angles by conducting two-way repeated measures ANOVA models. Results: Under an anterior tibial load at 30o flexion, the direct insertion carried 83.9% (±7.2%) of the total ACL load compared to 16.1% (±7.2%) in the indirect insertion (p<0.001). The direct insertion also carried more load at 90o flexion (95.2% vs 4.8%; p<0.001). Under a combined rotatory load at 15o flexion, the direct insertion carried 84.2% (±4.2%)of the total ACL load compared to 15.8% (±4.2%) in the indirect insertion (p<0.001). Conclusion: The fibres in the direct insertion of the ACL carry more load than fibres in the indirect insertion. Previous studies have suggested that the direct insertion plays a major role in the mechanical link between the ACL and bone. With the current shift in emphasis towards anatomic ACL reconstruction, it may be beneficial to create the femoral tunnel within the direct insertion rather than ‘lower’ in the notch. Although further work is required in determining graft behaviour at the new insertions sites described in this study, our findings suggest that placing a graft in the region of the direct insertion may be an important consideration when adhering to the principles of anatomic ACL reconstruction.
Ishiguro, Naotaka; Inoshima, Yasuo; Yanai, Tokuma; Sasaki, Motoki; Matsui, Akira; Kikuchi, Hiroki; Maruyama, Masashi; Hongo, Hitomi; Vostretsov, Yuri E; Gasilin, Viatcheslav; Kosintsev, Pavel A; Quanjia, Chen; Chunxue, Wang
2016-02-01
The mitochondrial DNA (mtDNA) control region (198- to 598-bp) of four ancient Canis specimens (two Canis mandibles, a cranium, and a first phalanx) was examined, and each specimen was genetically identified as Japanese wolf. Two unique nucleotide substitutions, the 78-C insertion and the 482-G deletion, both of which are specific for Japanese wolf, were observed in each sample. Based on the mtDNA sequences analyzed, these four specimens and 10 additional Japanese wolf samples could be classified into two groups- Group A (10 samples) and Group B (4 samples)-which contain or lack an 8-bp insertion/deletion (indel), respectively. Interestingly, three dogs (Akita-b, Kishu 25, and S-husky 102) that each contained Japanese wolf-specific features were also classified into Group A or B based on the 8-bp indel. To determine the origin or ancestor of the Japanese wolf, mtDNA control regions of ancient continental Canis specimens were examined; 84 specimens were from Russia, and 29 were from China. However, none of these 113 specimens contained Japanese wolf-specific sequences. Moreover, none of 426 Japanese modern hunting dogs examined contained these Japanese wolf-specific mtDNA sequences. The mtDNA control region sequences of Groups A and B appeared to be unique to grey wolf and dog populations.
Active control of sound transmission through a double panel partition
NASA Astrophysics Data System (ADS)
Sas, P.; Bao, C.; Augusztinovicz, F.; Desmet, W.
1995-03-01
The feasibility of improving the insertion loss of lightweight double panel partitions by using small loudspeakers as active noise control sources inside the air gap between both panels of the partition is investigated analytically, numerically and experimentally in this paper. A theoretical analysis of the mechanisms of the fluid-structure interaction of double panel structures is presented in order to gain insight into the physical phenomena underlying the behaviour of a coupled vibro-acoustic system controlled by active methods. The analysis, based on modal coupling theory, enables one to derive some qualitative predictions concerning the potentials and limitations of the proposed approach. The theoretical analysis is valid only for geometrically simple structures. For more complex geometries, numerical simulations are required. Therefore the potential use of active noise control inside double panel structures has been analyzed by using coupled finite element and boundary element methods. To verify the conclusions drawn from the theoretical analysis and the numerical calculation and, above all, to demonstrate the potential of the proposed approach, experiments have been conducted with a laboratory set-up. The performance of the proposed approach was evaluated in terms of relative insertion loss measurements. It is shown that a considerable improvement of the insertion loss has been achieved around the lightly damped resonances of the system for the frequency range investigated (60-220 Hz).
Beer, Andreas; Gahleitner, André; Holm, Anders; Birkfellner, Wolfgang; Homolka, Peter
2007-02-01
The aim of this study was to quantify the effect of adapted preparation on the insertion torque of self-tapping implants in cancellous bone. In adapted preparation, bone condensation - and thus, insertion torque - is controlled by changing the diameter of the drilling. After preparation of cancellous porcine vertebral bone with drills of 2.85, 3, 3.15 or 3.35 mm final diameters, Brånemark sytem Mk III implants (3.75 x 11.5 mm) were inserted in 141 sites. During implantation, the insertion torque was recorded. Prior to implant insertion, bone mineralization (bone mineral density (BMD)) was measured with dental quantative computed tomography. The BMD values measured at the implant position were correlated with insertion torque for varying bone condensation. Based on the average torque recorded during implant insertion into the pre-drilled canals with a diameter of 3 mm, torque increased by approximately 17% on reducing the diameter of the drill by 5% (to 2.85 mm). On increasing the diameter of the osteotomy to 3.15 mm (5%) or 3.35 mm (12%), torque values decreased by approximately 21% and 50%, respectively. The results demonstrate a correlation between primary stability (average insertion torque) and the diameter of the implant bed on using a screw-shaped implant. Thus, using an individualized bone mineralization-dependent drilling technique, optimized torque values could be achieved in all tested bone qualities with BMDs ranging from 330 to 500 mg/cm(3). The results indicate that using a bone-dependent drilling technique, higher torque values can also be achieved in poor bone using an individualized drilling resulting in higher bone condensation. As immediate function is dependent on primary stability (high insertion torque), this indicates that primary stability can be increased using a modified drilling technique in lesser mineralized bone.
de Souza, Marco Aurélio Martins; Geber, Selmo
2006-02-01
An intrauterine device (IUD) is one of the most frequently used methods of birth control around the world. Although a relationship between its use and menstrual disorders has been well documented, only a few studies have tried to show whether there are any vascular modifications. The aim of our study was to evaluate the influence of an IUD on uterine artery blood flow using Doppler assessment. A total of 100 patients selected for IUD use were prospectively evaluated with Doppler analysis before and 30 days after insertion. The resistive index (RI) and pulsatility index (PI) were used to evaluate uterine artery vascular resistance. Patients were allocated in 2 groups according to whether they were (group 2) or were not (group 1) lactating. The PI and RI of the patients in groups 1 and 2 before and after IUD insertion were not statistically significantly different (P = .298 and .23). When we compared uterine artery blood flow indices before and after IUD insertion for groups 1 and 2 separately, we observed in group 1 that the mean +/- SD PI values were 2.45 +/- 0.62 and 2.55 +/- 0.55 (P = .38) and the RI values were 0.87 +/- 0.08 and 0.87 +/- 0.06 (P = .88) before and after IUD insertion, respectively. In group 2, the PI values were 2.31 +/- 0.55 and 2.37 +/- 0.69 (P = .68) and the RI values were 0.85 +/- 0.07 and 0.86 +/- 0.07 (P = .44) before and after IUD insertion. Finally, we used the mean blood flow indices of the uterine arteries of all patients to compare the effect of IUD insertion. Results were also not statistically significant when we compared PI and RI before and after IUD insertion. The presence of an IUD does not interfere with the vascular resistance of the uterine arteries that can be shown by Doppler flow assessments 1 month after insertion.
Inoue, Gen; Ueno, Masaki; Nakazawa, Toshiyuki; Imura, Takayuki; Saito, Wataru; Uchida, Kentaro; Ohtori, Seiji; Toyone, Tomoaki; Takahira, Naonobu; Takaso, Masashi
2014-09-01
The object of this study was to examine the efficacy of preoperative teriparatide treatment for increasing the insertional torque of pedicle screws during fusion surgery in postmenopausal women with osteoporosis. Fusion surgery for the thoracic and/or lumbar spine was performed in 29 postmenopausal women with osteoporosis aged 65-82 years (mean 72.2 years). The patients were divided into 2 groups based on whether they were treated with teriparatide (n = 13) or not (n = 16) before the surgery. In the teriparatide-treated group, patients received preoperative teriparatide therapy as either a daily (20 μg/day, n = 7) or a weekly (56.5 μg/week, n = 6) injection for a mean of 61.4 days and a minimum of 31 days. During surgery, the insertional torque was measured in 212 screws inserted from T-7 to L-5 and compared between the 2 groups. The correlation between the insertional torque and the duration of preoperative teriparatide treatment was also investigated. The mean insertional torque value in the teriparatide group was 1.28 ± 0.42 Nm, which was significantly higher than in the control group (1.08 ± 0.52 Nm, p < 0.01). There was no significant difference between the daily and the weekly teriparatide groups with respect to mean insertional torque value (1.34 ± 0.50 Nm and 1.18 ± 0.43 Nm, respectively, p = 0.07). There was negligible correlation between insertional torque and duration of preoperative teriparatide treatment (r(2) = 0.05, p < 0.01). Teriparatide injections beginning at least 1 month prior to surgery were effective in increasing the insertional torque of pedicle screws during surgery in patients with postmenopausal osteoporosis. Preoperative teriparatide treatment might be an option for maximizing the purchase of the pedicle screws to the bone at the time of fusion surgery.
Actinomyces-like organisms in the cervical smears of IUCD users.
Farida Jamal; Mohd Salleh Mohd Yasin; Zooraidah Zainal; Hamid Arshat
1983-01-01
Pelvic inflammatory disease (PID) is a well-documented complication of IUD use. The presence of tails on the IUDs appears to facilitate ascent of bacteria from the vagina into the uterus. In this study, cervical smears of 128 IUD users were stained by Gram's stain and screened for the presence of Actinomyces-like organisms. 5.5% of the smears were positive for these organisms. Pus was seen in 20.1% of the smears, and yeast cells were seen in 10.2%. The average duration of IUD insertion was 8 months. Smears of 103 controls were negative for Actinomyces-like organisms, pus cells were present in 8.7%, and yeast cells in 4.8%. Of the 7 smears positive for the organisms, only 1 was from the user of a plastic device. All cases included were asymptomatic and were visiting the clinic for routine follow-up. These data suggest that colonization by Actinomyces-like organisms does not appear to be a significant problem in IUD users in Malaysia.
Takada, Koji; Yamada, Yuki; Watanabe, Eriko; Wang, Jianhui; Sodeyama, Keitaro; Tateyama, Yoshitaka; Hirata, Kazuhisa; Kawase, Takeo; Yamada, Atsuo
2017-10-04
The passivation of negative electrodes is key to achieving prolonged charge-discharge cycling with Na-ion batteries. Here, we report the unusual passivation ability of superconcentrated Na-salt electrolytes. For example, a 50 mol % sodium bis(fluorosulfonyl)amide (NaFSA)/succinonitrile (SN) electrolyte enables highly reversible Na + insertion into a hard carbon negative electrode without any electrolyte additive, functional binder, or electrode pretreatment. Importantly, an anion-derived passivation film is formed via preferential reduction of the anion upon charging, which can effectively suppress further electrolyte reduction. As a structural characteristic of the electrolyte, most anions are coordinated to multiple Na + cations at high concentration, which shifts the lowest unoccupied molecular orbitals of the anions downward, resulting in preferential anion reduction. The present work provides a new understanding of the passivation mechanism with respect to the coordination state of the anion.
Castle, Nick; Owen, Robert; Hann, Mark; Naidoo, Raveen; Reeves, David
2010-11-01
Control of the airway is a priority during cardiopulmonary resuscitation and/or following a failed intubation attempt. Supraglottic airway devices provide more effective airway management than bag-valve-mask-ventilation (BVMV) and can be effectively used by non-anaesthetists. 36 paramedic students were timed to ascertain how long it took them to place an Igel, laryngeal mask airway (LMA) or laryngeal tube airway (LTA) into a manikin. Following insertion, students were interviewed to see which device they preferred and why. The Igel was consistently the fastest airway device, taking a mean of 12.3 s (95% CI 11.5 to 13.1) to insert, the LTA took a mean time of 22.4 s (95% CI 20.3 to 24.5) and the LMA 33.8 s (95% CI 30.9 to 36.7). 63% of students would choose the Igel as their preferred intermediate airway device, stating ease of use and speed of insertion as the primary reasons. The ease and speed at which a supraglottic airway can be inserted means that it is a viable alternative to the use of the BVMV.
Li, Zheng-Yao; Wang, Huibo; Yang, Wenyun; Yang, Jinbo; Zheng, Lirong; Chen, Dongfeng; Sun, Kai; Han, Songbai; Liu, Xiangfeng
2018-01-17
Exploiting advanced layered transition metal oxide cathode materials is of great importance to rechargeable sodium batteries. Layered oxides are composed of negatively charged TMO 2 slabs (TM = transition metal) separated by Na + diffusion layers. Herein, we propose a novel insight, for the first time, to control the electrochemical properties by tuning Coulombic repulsion between negatively charged TMO 2 slabs. Coulombic repulsion can finely tailor the d-spacing of Na ion layers and material structural stability, which can be achieved by employing Na + cations to serve as effective shielding layers between TMO 2 layers. A series of O3-type Na x Mn 1/3 Fe 1/3 Cu 1/6 Mg 1/6 O 2 (x = 1.0, 0.9, 0.8, and 0.7) have been prepared, and Na 0.7 Mn 1/3 Fe 1/3 Cu 1/6 Mg 1/6 O 2 shows the largest Coulombic repulsion between TMO 2 layers, the largest space for Na ion diffusion, the best structural stability, and also the longest Na-O chemical bond with weaker Coulombic attraction, thus leading to the best electrochemical performance. Meanwhile, the thermal stability depends on the Na concentration in pristine materials. Ex situ X-ray absorption (XAS) analysis indicates that Mn, Fe, and Cu ions are all electrochemically active components during insertion and extraction of sodium ion. This study enables some new insights to promote the development of advanced layered Na x TMO 2 materials for rechargeable sodium batteries in the future.
Concept of a Cryogenic System for a Cryogen-Free 25 T Superconducting Magnet
NASA Astrophysics Data System (ADS)
Iwai, Sadanori; Takahashi, Masahiko; Miyazaki, Hiroshi; Tosaka, Taizo; Tasaki, Kenji; Hanai, Satoshi; Ioka, Shigeru; Watanabe, Kazuo; Awaji, Satoshi; Oguro, Hidetoshi
A cryogen-free 25 T superconducting magnet using a ReBCO insert coil that generates 11.5 T in a 14 T background field of outer low-temperature superconducting (LTS) coils is currently under development. The AC loss of the insert coil during field ramping is approximately 8.8 W, which is difficult to dissipate at the operating temperature of the LTS coils (4 K). However, since a ReBCO coil can operate at a temperature above 4 K, the ReBCO insert coil is cooled to about 10 K by two GM cryocoolers, and the LTS coils are independently cooled by two GM/JT cryocoolers. Two GM cryocoolers cool a circulating helium gas through heat exchangers, and the gas is transported over a long distance to the cold stage located on the ReBCO insert coil, in order to protect the cryocoolers from the leakage field of high magnetic fields. The temperature difference of the 2nd cold stage of the GM cryocoolers and the insert coil can be reduced by increasing the gas flow rate. However, at the same time, the heat loss of the heat exchangers increases, and the temperature of the second cold stage is raised. Therefore, the gas flow rate is optimized to minimize the operating temperature of the ReBCO insert coil by using a flow controller and a bypass circuit connected to a buffer tank.
Cancer gene discovery: exploiting insertional mutagenesis
Ranzani, Marco; Annunziato, Stefano; Adams, David J.; Montini, Eugenio
2013-01-01
Insertional mutagenesis has been utilized as a functional forward genetics screen for the identification of novel genes involved in the pathogenesis of human cancers. Different insertional mutagens have been successfully used to reveal new cancer genes. For example, retroviruses (RVs) are integrating viruses with the capacity to induce the deregulation of genes in the neighborhood of the insertion site. RVs have been employed for more than 30 years to identify cancer genes in the hematopoietic system and mammary gland. Similarly, another tool that has revolutionized cancer gene discovery is the cut-and-paste transposons. These DNA elements have been engineered to contain strong promoters and stop cassettes that may function to perturb gene expression upon integration proximal to genes. In addition, complex mouse models characterized by tissue-restricted activity of transposons have been developed to identify oncogenes and tumor suppressor genes that control the development of a wide range of solid tumor types, extending beyond those tissues accessible using RV-based approaches. Most recently, lentiviral vectors (LVs) have appeared on the scene for use in cancer gene screens. LVs are replication defective integrating vectors that have the advantage of being able to infect non-dividing cells, in a wide range of cell types and tissues. In this review, we describe the various insertional mutagens focusing on their advantages/limitations and we discuss the new and promising tools that will improve the insertional mutagenesis screens of the future. PMID:23928056
Benghalem, Abdelhamid; Gazibegovic, Dzemal; Saadi, Fatima; Tazi-Chaoui, Zakia
2017-01-01
Atraumatic insertion of the HiFocus TM Mid-Scala (HFMS) electrode via the round window was successfully achieved in seven children. Residual hearing 6 months post-operatively was preserved to within 10 dB HL of the pre-operative audiogram at 500 Hz for six children, indicating minimal initial insertion trauma to the cochlea. The objectives were to document the clinical experience and evaluate differences between HFMS and HiFocus TM 1j (HF1j) by means of insertion depth and hearing preservation results. Nineteen children were prospectively recruited and consecutively implanted with the HF1j electrode (n = 12) or the HFMS electrode (n = 7) via the round window. Average median angular insertion depths and the amount of residual hearing preserved at 6 months post-operatively were compared between the two electrode groups. The median angular insertion depth for the HF1j was 439° and for the HFMS 435°. Preservation of residual hearing at 500 Hz was assessed in seven HFMS subjects and 11 HF1j subjects. Based on the Skarzynski formula, three out of seven subjects (42%) in the HFMS group had their residual hearing completely preserved at 500 Hz. In the control group, no subjects had complete hearing preservation and five subjects had a complete loss of residual hearing.
Sato, Hidemasa; Kawamura, Akira; Yamaguchi, Masaru; Kasai, Kazutaka
2005-12-01
The purposes of this study were to investigate bone mineral density as a part of bone construction in human skulls and to examine the relationship between dentofacial morphology and masticatory function by using computed tomography (CT) findings. Changes in bone mineral density in the mandible because of loss of masticatory function were tested in rats by experimentally producing an environment that inhibited mastication by the molars. Data for the human study were obtained from 27 modern male Japanese skulls (mean age, 28 years) from the University of Tokyo. Cortical bone thickness (CBT) and CT value (CV) were measured by each CT scan of the first and molars. For the animal study, a metal cap was inserted between the maxillary and mandibular incisors to prevent the molars from biting in 6-week-old male Wistar rats. The rats were killed after 2, 4, or 6 weeks, and bone mineral density was measured in cancellous and cortical bone equivalent to the first molar region by using peripheral quantitative computed tomography. In the human skull study, significant negative correlations were observed between CV in the regions of the buccal side of the second molar and the angle between the Frankfort horizontal and mandibular planes. Significant negative correlations were also observed between the gonial angle and CV in the buccal and basal sides. In the animal study, cancellous bone mineral density began to decline 4 weeks after the start of the experiment in the masticatory hypofunction group compared with the control group. By week 6, cancellous bone density had declined by 11.6% on the buccal side, 16.7% on the lingual side, 12.3% at the bifurcation of the root, and 38.1% at the root apex. Cortical bone density declined by 8% to 12% on the lingual side. The results support our hypothesis that a functional adaptive response by the mandible to mechanical stress resulting from mastication occurs not only in the muscle insertion area, but also in mandibular alveolar bone in the molar region.
1992-08-17
Conclusions. Key personnel planned and administered the 193-nm lithography SBIR workshop on May 7, 1992 as well as planned the GaAs Insertion...converters can use Josephson junctions (JJ) to improve performance. Superconductive quantum interference devices (SQUIDs), such as JJs, are used to form...forward control of a lithography stepper. Mark Conner at Booz-Allen has copies of the charts. You should take a few minutes to review them. I asked Costos
CdTe-based Light-Controllable Frequency-Selective Photonic Crystal Switch for Millimeter Waves
2011-09-01
position (magenta curves with circular points which correspond to different light pulses) 23 Fig. 11.3. (a) Phase of transmission wave (in...11.4. Transmission spectra of plastic-air PC with CdTe-coated triple -quartz-wafer insertion of the kind ‘6t-qvqvqs-6t’ (computed yellow and measured...experimental requirements of matching the frequency band of VNA facility (f = 75–110 GHz), PC structures with triple -wafer insertion layers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Xi; Wang, Shouguo, E-mail: sgwang@ustb.edu.cn; Han, Gang
2015-09-15
The Blocking temperature (T{sub B}) of Pt/NiFe/IrMn/MgO/Pt multilayers was greatly enhanced from far below room temperature (RT) to above RT by inserting 1 nm thick Mg layer at IrMn/MgO interface. Furthermore, the exchange bias field (H{sub eb}) was increased as well by the control of interfacial structures. The evidence for a significant fraction of Mn-O bonding at IrMn/MgO interface without Mg insertion layer was provided by X-ray photoelectron spectroscopy. The bonding between Mn and O can decrease the antiferromagnetism of IrMn film, leading to lower value of T{sub B} in Pt/NiFe/IrMn/MgO/Pt multilayers. Ultrathin Mg film inserted at IrMn/MgO interface actingmore » as an oxygen sinking layer can suppress the oxidation reactions between Mn and O and reduce the formation of Mn-O bonding greatly. The oxidation suppression results in the recovery of the antiferromagnetism of IrMn film, which can enhance T{sub B} and H{sub eb}. Furthermore, the high resolution transmission electron microscopy demonstrates that the Mg insertion layer can efficiently promote a high-quality MgO (200) texture. This study will enhance the understanding of physics in antiferromagnet-based spintronic devices.« less
Fixation of revision implants is improved by a surgical technique to crack the sclerotic bone rim.
Kold, Søren; Bechtold, Joan E; Mouzin, Olivier; Elmengaard, Brian; Chen, Xinqian; Søballe, Kjeld
2005-03-01
Revision joint replacement has poorer outcomes compared with primary joint replacement, and these poor outcomes have been associated with poorer fixation. We investigated a surgical technique done during the revision operation to improve access from the marrow space to the implant interface by locally cracking the sclerotic bone rim that forms during aseptic loosening. Sixteen implants were inserted bilaterally by distal femur articulation of the knee joint of eight dogs, using our controlled experimental model that replicates the revision setting (sclerotic bone rim, dense fibrous tissue, macrophages, elevated cytokines) by pistoning a loaded 6.0-mm implant 500 microm into the distal femur with particulate PE. At 8 weeks, one of two revision procedures was done. Both revision procedures included complete removal of the membrane, scraping, lavaging, and inserting a revision plasma-spray Ti implant. The crack revision procedure also used a splined tool to circumferentially locally perforate the sclerotic bone rim before insertion of an identical revision implant. Superior fixation was achieved with the cracking procedure in this experimental model. Revision implants inserted with the rim cracking procedure had a significantly higher pushout strength (fivefold median increase) and energy to failure (sixfold median increase), compared with the control revision procedure. Additional evaluation is needed of local perforation of sclerotic bone rim as a simple bone-sparing means to improve revision implant fixation and thereby increase revision implant longevity.
Cargo Movement Operations System (CMOS) Requirements Traceability Matrix, Critical Design Review
1990-07-16
NO [ ] COMMENT DISPOSITION: ACCEPT [ ] REJECT [ J COY1MENT STATUS: OPEN [ ] CLOSED [ ] Cmnt Page Paragraph No. No. Number Comment 1. 1-320 SS0811, The references to Advanced TCMD were J-201 CUC1209 misspelled. 2. J-193 CUlC0650 Insert a space between "DDN" and "IN". 3. J-197 CUICI050 Insert a space between "ICI" and "IN". 4. J-206 CU1C12l3 Add "or" to the end of the header. ORIGINATOR CONTROL NUMBER: RTM-0002 PROGRAM OFFICE CONTROL NUMBER: DATA ITEM DISCREPANCY WORKSHEET CDRL NUMBER: A018-04 DATE: 07/16/90
Haines, Bryan; Hughes, James; Corbett, Mark; Shaw, Marie; Innes, Josie; Patel, Leena; Gecz, Jozef; Clayton-Smith, Jill; Thomas, Paul
2015-05-01
46,XX male sex reversal occurs in approximately 1: 20 000 live births and is most commonly caused by interchromosomal translocations of the Y-linked sex-determining gene, SRY. Rearrangements of the closely related SOX3 gene on the X chromosome are also associated with 46,XX male sex reversal. It has been hypothesized that sex reversal in the latter is caused by ectopic expression of SOX3 in the developing urogenital ridge where it triggers male development by acting as an analog of SRY. However, altered regulation of SOX3 in individuals with XX male sex reversal has not been demonstrated. Here we report a boy with SRY-negative XX male sex reversal who was diagnosed at birth with a small phallus, mixed gonads, and borderline-normal T. Molecular characterization of the affected individual was performed using array comparative genomic hybridization, fluorescent in situ hybridization of metaphase chromosomes, whole-genome sequencing, and RT-PCR expression analysis of lymphoblast cell lines. The affected male carries ∼774-kb insertion translocation from chromosome 1 into a human-specific palindromic sequence 82 kb distal to SOX3. Importantly, robust SOX3 expression was identified in cells derived from the affected individual but not from control XX or XY cells, indicating that the translocation has a direct effect on SOX3 regulation. This is the first demonstration of altered SOX3 expression in an individual with XX male sex reversal and suggests that SOX3 can substitute for SRY to initiate male development in humans.
de Freitas, Adriana Rodrigues; Sales-Peres, Arsênio; Ceneviva, Reginaldo
2015-01-01
The aim of this study was to identify the impact of oral disease on the quality of life of morbid obese and normal weight individuals. Cohort was composed of 100 morbid-obese and 50 normal-weight subjects. Dental caries, community periodontal index, gingival bleeding on probing (BOP), calculus, probing pocket depth, clinical attachment level, dental wear, stimulated salivary flow, and salivary pH were used to evaluate oral diseases. Socioeconomic and the oral impacts on daily performances (OIDP) questionnaires showed the quality of life in both groups. Unpaired Student, Fisher’s Exact, Chi-Square, Mann-Whitney, and Multiple Regression tests were used (p<0.05). Obese showed lower socio-economic level than control group, but no differences were found considering OIDP. No significant differences were observed between groups considering the number of absent teeth, bruxism, difficult mastication, calculus, initial caries lesion, and caries. However, saliva flow was low, and the salivary pH was changed in the obese group. Enamel wear was lower and dentine wear was higher in obese. More BOP, insertion loss, and periodontal pocket, especially the deeper ones, were found in obese subjects. The regression model showed gender, smoking, salivary pH, socio-economic level, periodontal pocket, and periodontal insertion loss significantly associated to obesity. However, both OIDP and BOP did not show significant contribution to the model. The quality of life of morbid obese was more negatively influenced by oral disease and socio-economic factors than in normal weight subjects. PMID:26177268
Reimmann, C; Rella, M; Haas, D
1988-06-01
R68.45 and other similar broad-host-range (IncP) plasmids carrying a tandem repeat of the 2.1 kb insertion element IS21 mobilize the chromosome of many different Gram-negative bacteria. To analyse the structure of R68.45-chromosome cointegrates, whose involvement in the mobilization process had been postulated previously, we selected for the stable integration of R68.45-like plasmids into the Pseudomonas aeruginosa chromosome. Two plasmids were chosen: pME28, a transfer-deficient, mobilizable RP1 derivative with an inactive replication control (trfA) gene, and pME487, an R68.45 derivative with a trfA(ts) mutation causing temperature-sensitive replication. Chromosomally integrated pME28 and pME487 were found to be flanked by single IS21 elements. This structure is in agreement with a 'cut-and-paste' mode of R68.45 transposition. pME28 and pME487 showed a low specificity of insertion but rarely (less than 0.1%) induced auxotrophic mutations. Hfr (high-frequency-of-recombination) donors of P. aeruginosa could be obtained by chromosomal integration of pME487 or pME28; in the latter case, the transfer functions lacking from pME28 had to be provided in trans on an autonomous plasmid. Hfr donors gave higher conjugational linkage and transferred longer stretches of the P. aeruginosa chromosome than did R68.45 donors. This suggests that the integration of R68.45 into the donor chromosome is short-lived in P. aeruginosa.
DeCaro, Renee; Peelle, Jonathan E.; Grossman, Murray; Wingfield, Arthur
2016-01-01
Reduced hearing acuity is among the most prevalent of chronic medical conditions among older adults. An experiment is reported in which comprehension of spoken sentences was tested for older adults with good hearing acuity or with a mild-to-moderate hearing loss, and young adults with age-normal hearing. Comprehension was measured by participants’ ability to determine the agent of an action in sentences that expressed this relation with a syntactically less complex subject-relative construction or a syntactically more complex object-relative construction. Agency determination was further challenged by inserting a prepositional phrase into sentences between the person performing an action and the action being performed. As a control, prepositional phrases of equivalent length were also inserted into sentences in a non-disruptive position. Effects on sentence comprehension of age, hearing acuity, prepositional phrase placement and sound level of stimulus presentations appeared only for comprehension of sentences with the more syntactically complex object-relative structures. Working memory as tested by reading span scores accounted for a significant amount of the variance in comprehension accuracy. Once working memory capacity and hearing acuity were taken into account, chronological age among the older adults contributed no further variance to comprehension accuracy. Results are discussed in terms of the positive and negative effects of sensory–cognitive interactions in comprehension of spoken sentences and lend support to a framework in which domain-general executive resources, notably verbal working memory, play a role in both linguistic and perceptual processing. PMID:26973557
Kaleta, Jiří; Dron, Paul I; Zhao, Ke; Shen, Yongqiang; Císařová, Ivana; Rogers, Charles T; Michl, Josef
2015-06-19
A new generation of rod-shaped dipolar molecular rotors designed for controlled insertion into channel arrays in the surface of hexagonal tris(o-phenylenedioxy)cyclotriphosphazene (TPP) has been designed and synthesized. Triptycene is used as a stopper intended to prevent complete insertion, forcing the formation of a surface inclusion. Two widely separated (13)C NMR markers are present in the shaft for monitoring the degree of insertion. The structure of the two-dimensional rotor arrays contained in these surface inclusions was examined by solid-state NMR and X-ray powder diffraction. The NMR markers and the triptycene stopper functioned as designed, but half of the guest molecules were not inserted as deeply into the TPP channels as the other half. As a result, the dipolar rotators were distributed equally in two planes parallel to the crystal surface instead of being located in a single plane as would be required for ferroelectricity. Dielectric spectroscopy revealed rotational barriers of ∼4 kcal/mol but no ferroelectric behavior.
Galiczewski, Janet M; Shurpin, Kathleen M
2017-06-01
Healthcare associated infections from indwelling urinary catheters lead to increased patient morbidity and mortality. The purpose of this study was to determine if direct observation of the urinary catheter insertion procedure, as compared to the standard process, decreased catheter utilization and urinary tract infection rates. This case control study was conducted in a medical intensive care unit. During phase I, a retrospective data review was conducted on utilsiation and urinary catheter infection rates when practitioners followed the institution's standard insertion algorithm. During phase II, an intervention of direct observation was added to the standard insertion procedure. The results demonstrated no change in utilization rates, however, CAUTI rates decreased from 2.24 to 0 per 1000 catheter days. The findings from this study may promote changes in clinical practice guidelines leading to a reduction in urinary catheter utilization and infection rates and improved patient outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.
Zhang, Yi; Zhang, Lei; Fan, Yu-bo; Song, Jin-lin; Deng, Feng
2009-10-01
To investigate the biomechanical effects of micro-implant anchorage technique with sliding mechanics on maxillary anterior teeth retraction under different implant insertion heights and different retraction hook heights. The three dimensional finite element model of maxillary anterior teeth retraction force system was constructed with CT scanning and MIMICS software and the relationships between brackets, teeth, wire and micro-implant were simulating the clinical factions. Then the initial tooth displacement was calculated when the insertion heights were 4 mm and 8 mm and the retraction hook heights were 1, 4, 7, 10 mm respectively. With retraction hook height added, the anterior teeth movement changed from lingual crown tipping to labial crown tipping and the intrusion movement was more apparent when the micro-implant was inserted in a higher location. The ideal teeth movement control could be achieved by different insertion heights of micro-implant and different retraction hook heights in straight wire retraction force system.
Electron-rich driven electrochemical solid-state amorphization in Li-Si alloys.
Wang, Zhiguo; Gu, Meng; Zhou, Yungang; Zu, Xiaotao; Connell, Justin G; Xiao, Jie; Perea, Daniel; Lauhon, Lincoln J; Bang, Junhyeok; Zhang, Shengbai; Wang, Chongmin; Gao, Fei
2013-09-11
The physical and chemical behaviors of materials used in energy storage devices, such as lithium-ion batteries (LIBs), are mainly controlled by an electrochemical process, which normally involves insertion/extraction of ions into/from a host lattice with a concurrent flow of electrons to compensate charge balance. The fundamental physics and chemistry governing the behavior of materials in response to the ions insertion/extraction is not known. Herein, a combination of in situ lithiation experiments and large-scale ab initio molecular dynamics simulations are performed to explore the mechanisms of the electrochemically driven solid-state amorphization in Li-Si systems. We find that local electron-rich condition governs the electrochemically driven solid-state amorphization of Li-Si alloys. This discovery provides the fundamental explanation of why lithium insertion in semiconductor and insulators leads to amorphization, whereas in metals, it leads to a crystalline alloy. The present work correlates electrochemically driven reactions with ion insertion, electron transfer, lattice stability, and phase equilibrium.
Electron-Rich Driven Electrochemical Solid-State Amorphization in Li-Si Alloys
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Zhiguo; Gu, Meng; Zhou, Yungang
2013-08-14
The physical and chemical behaviors of materials used in energy storage devices, such as lithium-ion batteries (LIBs), are mainly controlled by an electrochemical process, which normally involves insertion/extraction of ions into/from a host lattice with a concurrent flow of electrons to compensate charge balance. The fundamental physics and chemistry governing the behavior of materials in response to the ions insertion/extraction is not known. Herein, a combination of in situ lithiation experiments and large-scale ab initio molecular dynamics simulations are performed to explore the mechanisms of the electrochemically driven solid-state amorphization in Li-Si systems. We find that local electron-rich condition governsmore » the electrochemically driven solid-state amorphization of Li-Si alloys. This discovery provides the fundamental explanation of why lithium insertion in semiconductor and insulators leads to amorphization, whereas in metals, it leads to a crystalline alloy. The present work correlates electrochemically driven reactions with ion insertion, electron transfer, lattice stability and phase equilibrium.« less
Incorporation of mRNA in Lamellar Lipid Matrices for Parenteral Administration.
Ziller, Antje; Nogueira, Sara S; Hühn, Eva; Funari, Sergio S; Brezesinski, Gerald; Hartmann, Hermann; Sahin, Ugur; Haas, Heinrich; Langguth, Peter
2018-02-05
Insertion of high molecular weight messenger RNA (mRNA) into lyotropic lipid phases as model systems for controlled release formulations for the mRNA was investigated. Low fractions of 1,2-dioleoyl-3-trimethylammonium-propane (DOTAP) were used as an anchor to load the mRNA into a lamellar lipid matrix. Dispersions of zwitterionic lipid in the aqueous phase in the presence of increasing fractions of mRNA and cationic lipid were prepared, and the molecular organization was investigated as a function of mRNA and cationic lipid fraction. Insertion of both cationic lipid and mRNA was clearly proven from the physicochemical characteristics. The d-spacing of the lipid bilayers, as determined by small-angle X-ray scattering (SAXS) measurements, responded sensitively to the amount of inserted DOTAP and mRNA. A concise model of the insertion of the mRNA in the lipid matrices was derived, indicating that the mRNA was accommodated in the aqueous slab between lipid bilayers. Depending on the DOTAP and mRNA fraction, a different excess of water was present in this slab. Results from further physicochemical characterization, including determination of free and bound mRNA, zeta potential, and calorimetry data, were in line with this assumption. The structure of these concentrated lipid/mRNA preparations was maintained upon dilution. The functionality of the inserted mRNA was proven by cell culture experiments using C2C12 murine myoblast cells with the luciferase-encoding mRNA. The described lipid phases as carriers for the mRNA may be applicable for different routes of local administration, where control of the release kinetics and the form of the released mRNA (bound or free) is required.
Das, Bikramjit; Varshney, Rahul; Mitra, Subhro
2017-12-01
The ProSeal™ laryngeal mask airway (PLMA), i-gel™ and Laryngeal Tube Suction-D (LTS-D™) have previously been evaluated alone or in pair-wise comparisons but differing study designs make it difficult to compare the results. The aim of this study was to compare the clinical performance of these three devices in terms of efficacy and safety in patients receiving mechanical ventilation during elective surgical procedures. This prospective, randomised, double-blind study was conducted on 150 American Society of Anesthesiologists physical status I-II patients, randomly allocated into 3 groups, undergoing elective surgical procedures under general anaesthesia. PLMA, i-gel™ or LTS-D™ appropriate for weight or/and height was inserted. Primary outcome measured was airway sealing pressure. Insertion time, ease of insertion, number of attempts, overall success rate and the incidence of airway trauma and complications were also recorded. Intergroup differences were compared using one-way analysis of variance with post hoc correction for continuous data and Chi-square test for categorical variables. Overall success rate was comparable between the three devices (i-gel™ 100%, LTS-D™ 94%, PLMA 96%). Airway sealing pressure was lower with i-gel™ (23.38 ± 2.06 cm H 2 O) compared to LTS-D™ (26.06 ± 2.11 cm H 2 O) and PLMA (28.5 ± 2.8 cm H 2 O; P < 0.0005). The mean insertion time was significantly more in PLMA (38.77 ± 3.2 s) compared to i-gel™ (27.9 ± 2.53 s) and LTS-D™ (21.66 ± 2.31 s; P < 0.0005). Airway sealing pressure and insertion time were significantly higher in PLMA compared to i-gel™ and LTS-D™.
48 CFR 452.236-74 - Control of Erosion, Sedimentation, and Pollution.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., Sedimentation, and Pollution. 452.236-74 Section 452.236-74 Federal Acquisition Regulations System DEPARTMENT OF....236-74 Control of Erosion, Sedimentation, and Pollution. As prescribed in 436.574, insert the following clause: Control of Erosion, Sedimentation, and Pollution (NOV 1996) (a) Operations shall be...
48 CFR 452.236-74 - Control of Erosion, Sedimentation, and Pollution.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., Sedimentation, and Pollution. 452.236-74 Section 452.236-74 Federal Acquisition Regulations System DEPARTMENT OF....236-74 Control of Erosion, Sedimentation, and Pollution. As prescribed in 436.574, insert the following clause: Control of Erosion, Sedimentation, and Pollution (NOV 1996) (a) Operations shall be...
NUCLEAR REACTOR CONTROL SYSTEM
Epler, E.P.; Hanauer, S.H.; Oakes, L.C.
1959-11-01
A control system is described for a nuclear reactor using enriched uranium fuel of the type of the swimming pool and other heterogeneous nuclear reactors. Circuits are included for automatically removing and inserting the control rods during the course of normal operation. Appropriate safety circuits close down the nuclear reactor in the event of emergency.
48 CFR 436.574 - Control of erosion, sedimentation, and pollution.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., sedimentation, and pollution. 436.574 Section 436.574 Federal Acquisition Regulations System DEPARTMENT OF... 436.574 Control of erosion, sedimentation, and pollution. The contracting officer shall insert the clause at 452.236-74, Control of Erosion, Sedimentation and Pollution, if there is a need for applying...
48 CFR 436.574 - Control of erosion, sedimentation, and pollution.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., sedimentation, and pollution. 436.574 Section 436.574 Federal Acquisition Regulations System DEPARTMENT OF... 436.574 Control of erosion, sedimentation, and pollution. The contracting officer shall insert the clause at 452.236-74, Control of Erosion, Sedimentation and Pollution, if there is a need for applying...
48 CFR 436.574 - Control of erosion, sedimentation, and pollution.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., sedimentation, and pollution. 436.574 Section 436.574 Federal Acquisition Regulations System DEPARTMENT OF... 436.574 Control of erosion, sedimentation, and pollution. The contracting officer shall insert the clause at 452.236-74, Control of Erosion, Sedimentation and Pollution, if there is a need for applying...
48 CFR 452.236-74 - Control of Erosion, Sedimentation, and Pollution.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., Sedimentation, and Pollution. 452.236-74 Section 452.236-74 Federal Acquisition Regulations System DEPARTMENT OF....236-74 Control of Erosion, Sedimentation, and Pollution. As prescribed in 436.574, insert the following clause: Control of Erosion, Sedimentation, and Pollution (NOV 1996) (a) Operations shall be...
48 CFR 436.574 - Control of erosion, sedimentation, and pollution.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., sedimentation, and pollution. 436.574 Section 436.574 Federal Acquisition Regulations System DEPARTMENT OF... 436.574 Control of erosion, sedimentation, and pollution. The contracting officer shall insert the clause at 452.236-74, Control of Erosion, Sedimentation and Pollution, if there is a need for applying...
48 CFR 452.236-74 - Control of Erosion, Sedimentation, and Pollution.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., Sedimentation, and Pollution. 452.236-74 Section 452.236-74 Federal Acquisition Regulations System DEPARTMENT OF....236-74 Control of Erosion, Sedimentation, and Pollution. As prescribed in 436.574, insert the following clause: Control of Erosion, Sedimentation, and Pollution (NOV 1996) (a) Operations shall be...
48 CFR 452.236-74 - Control of Erosion, Sedimentation, and Pollution.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., Sedimentation, and Pollution. 452.236-74 Section 452.236-74 Federal Acquisition Regulations System DEPARTMENT OF....236-74 Control of Erosion, Sedimentation, and Pollution. As prescribed in 436.574, insert the following clause: Control of Erosion, Sedimentation, and Pollution (NOV 1996) (a) Operations shall be...
48 CFR 436.574 - Control of erosion, sedimentation, and pollution.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., sedimentation, and pollution. 436.574 Section 436.574 Federal Acquisition Regulations System DEPARTMENT OF... 436.574 Control of erosion, sedimentation, and pollution. The contracting officer shall insert the clause at 452.236-74, Control of Erosion, Sedimentation and Pollution, if there is a need for applying...
Ding, Mingquan; Ye, Wuwei; Lin, Lifeng; He, Shae; Du, Xiongming; Chen, Aiqun; Cao, Yuefen; Qin, Yuan; Yang, Fen; Jiang, Yurong; Zhang, Hua; Wang, Xiyin; Paterson, Andrew H.; Rong, Junkang
2015-01-01
Cotton (Gossypium) stem trichomes are mostly single cells that arise from stem epidermal cells. In this study, a homeodomain-leucine zipper gene (HD1) was found to cosegregate with the dominant trichome locus previously designated as T1 and mapped to chromosome 6. Characterization of HD1 orthologs revealed that the absence of stem trichomes in modern Gossypium barbadense varieties is linked to a large retrotransposon insertion in the ninth exon, 2565 bp downstream from the initial codon in the At subgenome HD1 gene (At-GbHD1). In both the At and Dt subgenomes, reduced transcription of GbHD1 genes is caused by this insertion. The disruption of At-HD1 further affects the expression of downstream GbMYB25 and GbHOX3 genes. Analyses of primitive cultivated accessions identified another retrotransposon insertion event in the sixth exon of At-GbHD1 that might predate the previously identified retrotransposon in modern varieties. Although both retrotransposon insertions results in similar phenotypic changes, the timing of these two retrotransposon insertion events fits well with our current understanding of the history of cotton speciation and dispersal. Taken together, the results of genetics mapping, gene expression and association analyses suggest that GbHD1 is an important component that controls stem trichome development and is a promising candidate gene for the T1 locus. The interspecific phenotypic difference in stem trichome traits also may be attributable to HD1 inactivation associated with retrotransposon insertion. PMID:26133897
Male circumcision and risk of HIV acquisition among MSM.
Sánchez, Jorge; Sal Y Rosas, Victor G; Hughes, James P; Baeten, Jared M; Fuchs, Jonathan; Buchbinder, Susan P; Koblin, Beryl A; Casapia, Martín; Ortiz, Abner; Celum, Connie
2011-02-20
To assess the association between male circumcision, insertive anal sex practices, and HIV acquisition in a cohort of MSM. Data were from 1824 HSV-2-seropositive, HIV-seronegative MSM, 1362 (75%) from Peru and 462 (25%) from the US, who participated in a randomized placebo-controlled trial of HSV-2 suppression for HIV prevention (HPTN 039). Circumcision status was determined by examination at enrollment. HIV testing was done every 3 months for up to 18 months. Partner-specific sexual behavior for up to the last three partners during the previous 3 months was analyzed. There was no significant association between male circumcision and HIV acquisition in univariate analysis [relative risk (RR) = 0.84, 95% confidence interval (CI) 0.50-1.42]. In a prespecified multivariate analysis that assumed a linear relationship between the proportion of insertive acts and effect of circumcision on HIV acquisition, the interaction between circumcision and proportion of insertive acts was not significant (P = 0.11). In an exploratory analysis that categorized behavior with recent partners by proportion of insertive acts (<60 or ≥60% insertive acts), circumcision was associated with a nonstatistically significant 69% reduction in the risk of HIV acquisition (RR = 0.31, 95% CI 0.06-1.51) among men who reported at least 60% of insertive acts with recent male partners. Circumcision does not have a significant protective effect against HIV acquisition among MSM from Peru and US, although there may be reduced risk for men who are primarily insertive with their male partners. This association needs to be investigated across diverse cohorts of MSM.
Hognert, Helena; Kopp Kallner, Helena; Cameron, Sharon; Nyrelli, Christina; Jawad, Izabella; Heller, Rebecca; Aronsson, Annette; Lindh, Ingela; Benson, Lina; Gemzell-Danielsson, Kristina
2016-11-01
Does a progestin releasing subdermal contraceptive implant affect the efficacy of medical abortion if inserted at the same visit as the progesterone receptor modulator, mifepristone, at medical abortion? A etonogestrel releasing subdermal implant inserted on the day of mifepristone did not impair the efficacy of the medical abortion compared with routine insertion at 2-4 weeks after the abortion. The etonogestrel releasing subdermal implant is one of the most effective long acting reversible contraceptive methods. The effect of timing of placement on the efficacy of mifepristone and impact on prevention of subsequent unintended pregnancy is not known. This multicentre, randomized controlled, equivalence trial with recruitment between 13 October 2013 and 17 October 2015 included a total of 551 women with pregnancies below 64 days gestation opting for the etonogestrel releasing subdermal implant as postabortion contraception. Women were randomized to either insertion at 1 hour after mifepristone intake (immediate) or at follow-up 2-4 weeks later (delayed insertion). An equivalence design was used due to advantages for women such as fewer visits to the clinic with immediate insertion. The primary outcome was the percentage of women with complete abortion not requiring surgical intervention within 1 month. Secondary outcomes included insertion rates, pregnancy and repeat abortion rates during 6 months follow-up. Analysis was per protocol and by intention to treat. Women aged 18 years and older who had requested medical termination of a pregnancy up to 63 days of gestation and opted for an etonogestrel releasing contraceptive implant were recruited in outpatient family planning clinics in six hospitals in Sweden and Scotland. Efficacy of medical abortion was 259/275 (94.2%) in the immediate insertion group and 239/249 (96%) in the routine insertion group with a risk difference of 1.8% (95% CI -0.4 to 4.1%), which was within the ±5% margin of equivalence. The insertion rate was 275/277 (98.9%) in the immediate group compared to 187/261 (71.6%) women in the routine group (P < 0.001). At 6 months of follow-up significantly fewer women in the immediate group had become pregnant again (2/277, 0.8%) compared to the routine group (10/261, 3.8%) P = 0.018. For the main outcome loss to follow-up data was minimized through access to patient records. Efforts were made to reduce loss to follow-up also for secondary outcomes. The results of the sensitivity analysis did not differ from the intention to treat or per protocol analysis. Guidelines on postabortion contraception should be amended to include insertion of the etonogestrel releasing implant at the time of mifepristone intake for medical abortion up to and including a gestation of 63 days. This study was funded by the Swedish Research Council (2012-2844), Stockholm City County and Karolinska Institutet (ALF). The contraceptive implants were provided by Merck and supplied by MSD Sweden. HKK and KGD have received honorariums for giving lectures for MSD/Merck and have participated in the national (HKK and KGD) and international (KGD) medical advisory boards for MSD/Merck. The other authors have nothing to declare. ClinicalTrials number NCT01920022. 06 August 2013. 13 October 2013. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Turok, David K; Leeman, Lawrence; Sanders, Jessica N; Thaxton, Lauren; Eggebroten, Jennifer L; Yonke, Nicole; Bullock, Holly; Singh, Rameet; Gawron, Lori M; Espey, Eve
2017-12-01
Immediate postpartum levonorgestrel intrauterine device insertion is increasing in frequency in the United States, but few studies have investigated the effect of early placement on breast-feeding outcomes. This study examined the effect of immediate vs delayed postpartum levonorgestrel intrauterine device insertion on breast-feeding outcomes. We conducted this noninferiority randomized controlled trial at the University of Utah and the University of New Mexico Health Sciences Centers from February 2014 through March 2016. Eligible women were pregnant and planned to breast-feed, spoke English or Spanish, were aged 18-40 years, and desired a levonorgestrel intrauterine device. Enrolled women were randomized 1:1 to immediate postpartum insertion or delayed insertion at 4-12 weeks' postpartum. Prespecified exclusion criteria included delivery <37.0 weeks' gestational age, chorioamnionitis, postpartum hemorrhage, contraindications to levonorgestrel intrauterine device insertion, and medical complications of pregnancy that could affect breast-feeding. We conducted per-protocol analysis as the primary approach, as it is considered the standard for noninferiority studies; we also report the alternative intent-to-treat analysis. We powered the study for the primary outcome, breast-feeding continuation at 8 weeks, to detect a 15% noninferiority margin between groups, requiring 132 participants in each arm. The secondary study outcome, time to lactogenesis, used a validated measure, and was analyzed by survival analysis and log rank test. We followed up participants for ongoing data collection for 6 months. Only the data analysis team was blinded to the intervention. We met the enrollment target with 319 participants, but lost 34 prior to randomization and excluded an additional 26 for medical complications prior to delivery. The final analytic sample included 132 in the immediate group and 127 in the delayed group. Report of any breast-feeding at 8 weeks in the immediate group (79%; 95% confidence interval, 70-86%) was noninferior to that of the delayed group (84%; 95% confidence interval, 76-91%). The 5% difference in breast-feeding continuation at 8 weeks between the groups fell within the noninferiority margin (95% confidence interval, -5.6 to 15%). Time to lactogenesis (mean ± SD) in the immediate group, 65.3 ± 25.7 hours, was noninferior to that of the delayed group, 63.6 ± 21.6 hours. The mean difference between groups was 1.7 hours (95% confidence interval, -4.8 to 8.2 hours), noninferior by log-rank test. A total of 24 intrauterine device expulsions occurred in the immediate group compared to 2 in the delayed group (19% vs 2%, P < .001), consistent with the known higher expulsion rate with immediate vs delayed postpartum intrauterine device insertion. No intrauterine device perforations occurred in either group. Our results of noninferior breast-feeding outcomes between women with immediate and delayed postpartum levonorgestrel intrauterine device insertion suggest that immediate postpartum intrauterine device insertion is an acceptable option for women planning to breast-feed and use the levonorgestrel intrauterine device. Expulsion rates are higher with immediate postpartum levonorgestrel intrauterine device insertion compared to delayed insertion, but this disadvantage may be outweighed by the advantages of immediate initiation of contraception. Providers should offer immediate postpartum intrauterine device insertion to breast-feeding women planning to use the levonorgestrel intrauterine device. Copyright © 2017 Elsevier Inc. All rights reserved.
Bliska, James B; Wang, Xiaoying; Viboud, Gloria I; Brodsky, Igor E
2013-10-01
The innate immune system of mammals responds to microbial infection through detection of conserved molecular determinants called 'pathogen-associated molecular patterns' (PAMPs). Pathogens use virulence factors to counteract PAMP-directed responses. The innate immune system can in turn recognize signals generated by virulence factors, allowing for a heightened response to dangerous pathogens. Many Gram-negative bacterial pathogens encode type III secretion systems (T3SSs) that translocate effector proteins, subvert PAMP-directed responses and are critical for infection. A plasmid-encoded T3SS in the human-pathogenic Yersinia species translocates seven effectors into infected host cells. Delivery of effectors by the T3SS requires plasma membrane insertion of two translocators, which are thought to form a channel called a translocon. Studies of the Yersinia T3SS have provided key advances in our understanding of how innate immune responses are generated by perturbations in plasma membrane and other signals that result from translocon insertion. Additionally, studies in this system revealed that effectors function to inhibit innateimmune responses resulting from insertion of translocons into plasma membrane. Here, we review these advances with the goal of providing insight into how a T3SS can activate and inhibit innate immune responses, allowing a virulent pathogen to bypass host defences. © 2013 John Wiley & Sons Ltd.
Towards rebuilding vaginal support utilizing an extracellular matrix bioscaffold.
Liang, Rui; Knight, Katrina; Easley, Deanna; Palcsey, Stacy; Abramowitch, Steven; Moalli, Pamela A
2017-07-15
As an alternative to polypropylene mesh, we explored an extracellular matrix (ECM) bioscaffold derived from urinary bladder matrix (MatriStem™) in the repair of vaginal prolapse. We aimed to restore disrupted vaginal support simulating application via transvaginal and transabdominal approaches in a macaque model focusing on the impact on vaginal structure, function, and the host immune response. In 16 macaques, after laparotomy, the uterosacral ligaments and paravaginal attachments to pelvic side wall were completely transected (IACUC# 13081928). 6-ply MatriStem was cut into posterior and anterior templates with a portion covering the vagina and arms simulating uterosacral ligaments and paravaginal attachments, respectively. After surgically exposing the correct anatomical sites, in 8 animals, a vaginal incision was made on the anterior and posterior vagina and the respective scaffolds were passed into the vagina via these incisions (transvaginal insertion) prior to placement. The remaining 8 animals underwent the same surgery without vaginal incisions (transabdominal insertion). Three months post implantation, firm tissue bands extending from vagina to pelvic side wall appeared in both MatriStem groups. Experimental endpoints examining impact of MatriStem on the vagina demonstrated that vaginal biochemical and biomechanical parameters, smooth muscle thickness and contractility, and immune responses were similar in the MatriStem no incision group and sham-operated controls. In the MatriStem incision group, a 41% decrease in vaginal stiffness (P=0.042), a 22% decrease in collagen content (P=0.008) and a 25% increase in collagen subtypes III/I was observed vs. Sham. Active MMP2 was increased in both Matristem groups vs. Sham (both P=0.002). This study presents a novel application of ECM bioscaffolds as a first step towards the rebuilding of vaginal support. Pelvic organ prolapse is a common condition related to failure of the supportive soft tissues of the vagina; particularly at the apex and mid-vagina. Few studies have investigated methods to regenerate these failed structures. The overall goal of the study was to determine the feasibility of utilizing a regenerative bioscaffold in prolapse applications to restore apical (level I) and lateral (level II) support to the vagina without negatively impacting vaginal structure and function. The significance of our findings is two fold: 1. Implantation of properly constructed extracellular matrix grafts promoted rebuilding of level I and level II support to the vagina and did not negatively impact the overall functional, morphological and biochemical properties of the vagina. 2. The presence of vaginal incisions in the transvaginal insertion of bioscaffolds may compromise vaginal structural integrity in the short term. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Zhang, Yu-peng; Shi, Ya-min; Wang, Hua-dong; Hou, Shu-xun
2015-10-01
To evaluate the accuracy and safety of pedicle screw insertion with the aid of novel patient-specific drill-guide templates in scoliosis cases. Ten patients with scoliosis were selected to participate in the research (the observation group) from December 2013 to December 2014. The data was obtained from CT scanning, and put into the computer to perform reconstruction of spine, simulation of pedicle screw insertion, and design of patient-specific drill-guide templates with software. The templates were made with rapid prototyping technique. After sterilization, the templates were used to aid the pedicle screw insertion intraoperatively. The blood loss, operation duration, change of creatinine level pre- and post-operation, and complications related to pedicle screw insertion were recorded. The location of pedicle screws were graded so as to evaluate the accuracy. A comparative study was then performed with the data of ten scoliosis cases operated with free-hand method during the same period (control group). There were 5 cases of idiopathic scoliosis and 5 cases of congenital scoliosis in the observation group, including 3 males and 7 females. Their average age was 11.9 years old (ranged, 4 to 18 years old), and the average Cobb angle of main curve was 54.9° (ranged, 42.1° to 78.4°). There were also 5 cases of idiopathic scoliosis and 5 cases of congenital scoliosis in the control group,including 2 males and 8 females. Their average age was 12.6 years old (ranged, 6 to 17 years old), and the average Cobb angle of main curve was 56.6° (ranged, 38.2° to 93.4°). A total of 167 pedicle screws were inserted intraoperatively, with 138 screws (82.6%) in grade I, 26 screws (15.0%) in grade II, 4 screws in grade III (2.4%), but no screws in grade IV according to the CT image. There were 29 (17.4%) screws perforated, and 163 (97.6%) screws could be accepted. In the control group, a total of 165 pedicle screws were inserted intraoperatively, with 98 screws (59.4%) in grade I, 39 screws (23.6%) in grade II, 21 screws in grade III (12.7%), and 7 screws in grade IV (4.2%). There were 67 (40.6%) screws perforated, and 137 (83.0%) screws could be accepted. The grade distribution of screw position, ratio of perforated and accepted screws were significantly different between the two groups respectively (Z=-5.013, P=0.000; χ2=9.347, P=0.002; χ2=20.242, P=0.000). The correction rate of Cobb angle were (74.1±10.0)% vs (69.7±17.6)%; blood loss were (455±447) ml vs (415±389) ml; operation duration were (163.5±53.7) min vs (164.0±48.7) min; and the changes of creatinine level pre- and post-operatively were (-5.3±3.2) μmol/L vs (-3.4±3.1) μmol/L; all above data had no significant differences respectively (t=0.696, P=0.496; t=0.214, P=0.833; t=0.022, P=0.983; t=1.375, P=0.192). There were no complications related to pedicle screw insertion in each group. The novel patient-specific drill guide template can be used to assist the insertion of pedicle screws in scoliosis cases with much higher accuracy than that of freehand method and fair safety.
Blood monitoring systems and methods thereof
NASA Technical Reports Server (NTRS)
Zander, Dennis (Inventor); Mir, Jose (Inventor)
2012-01-01
A blood monitoring system is capable of monitoring the blood of a subject in vivo. The blood monitoring system comprises: 1) an array of movable microneedle micromachined within associated wells; 2) array of motion actuators able to move each needle in and out of their associated wells; 3) array of microvalves associated with each microneedle able to control the flow of air around the microneedle; 4) an array of chemical sensors inserted into patient by movable microneedles; 5) an array of inductors able to measure chemical concentration in the vicinity of inserted chemical sensors; 6) conducting vias that provide timed actuating signal signals from a control system to each motion actuator; 7) conducting vias that transmit signal produced by array of chemical sensors to the control system for processing, although the blood monitoring system can comprise other numbers and types of elements in other configurations.
Coolman, B R; Marretta, S M; Kakoma, I; Wallig, M A; Coolman, S L; Paul, A J
1998-12-01
The purpose of this study was to determine the effects of a one-minute chlorhexidine gluconate skin preparation protocol prior to cephalic vein catheterization. Twenty-three healthy beagle dogs had one leg aseptically prepared and the opposite leg served as a control. Twenty-six- and 77-hour time groups were studied. Chlorhexidine-treated legs had significantly lower cutaneous bacterial counts than the control legs prior to catheter insertion and prior to catheter withdrawal for both time groups. Control legs developed significantly more dermatitis than the treated legs after 77 h. A one-minute preparation with 4% chlorhexidine gluconate was an effective method for sustained reduction of cutaneous bacterial counts at peripheral intravenous catheter insertion points in dogs. Increased cutaneous bacterial counts were associated with significantly more microscopic dermatitis in untreated legs after 77 h of catheterization.
Avidor, Boaz; Matus, Natalia; Girshengorn, Shirley; Achsanov, Svetlana; Gielman, Simona; Zeldis, Irene; Schweitzer, Inbal; Adler, Amos; Turner, Dan
2017-08-01
HIV-1 viral load (VL) testing is important to predict viral progression and to monitor the response to antiretroviral therapy. New HIV-1 VL tests are continuously introduced to the market. Their performance is usually compared to Abbott and/or Roche HIV-1 VL assays, as reference. The Xpert HIV-1 VL test was recently introduced, but its performance compared to Roche has not been sufficiently studied. To compare the Xpert assay with Roche and to assess its use in the HIV clinical laboratory. A total of 383 plasma samples of HIV-1 infected patients previously tested by Roche, were retrospectively tested by Xpert to determine concordance between the two assays. Samples included a diversity of HIV-1 subtypes and a wide range of VLs. There was a high concordance between the two assays, except for a CRF02_AG subtype variant with high VL titters, that was detected by Roche but undetected by Xpert. The 5' long terminal repeat gene region of this virus, targeted by the Xpert assay, was amplified and sequenced. A 25 nucleotide insert was identified, but was unmatched to any known sequences of HIV-1. This particular insert, however could not explain the false-negativity by the Xpert assay. This study underlines the challenge to routine VL testing due to the high genetic diversity of HIV-1. Clinicians should, therefore be advised that a negative VL in cases where the clinical picture does not match the laboratory report, might in fact be, a false-negative result of the VL assay. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhang, Shan; Zou, Zhengzhong; Kreth, Jens; Merritt, Justin
2017-01-01
Studies of the dental caries pathogen Streptococcus mutans have benefitted tremendously from its sophisticated genetic system. As part of our own efforts to further improve upon the S. mutans genetic toolbox, we previously reported the development of the first cloning-independent markerless mutagenesis (CIMM) system for S. mutans and illustrated how this approach could be adapted for use in many other organisms. The CIMM approach only requires overlap extension PCR (OE-PCR) protocols to assemble counterselectable allelic replacement mutagenesis constructs, and thus greatly increased the speed and efficiency with which markerless mutations could be introduced into S. mutans . Despite its utility, the system is still subject to a couple limitations. Firstly, CIMM requires negative selection with the conditionally toxic phenylalanine analog p -chlorophenylalanine (4-CP), which is efficient, but never perfect. Typically, 4-CP negative selection results in a small percentage of naturally resistant background colonies. Secondly, CIMM requires two transformation steps to create markerless mutants. This can be inherently problematic if the transformability of the strain is negatively impacted after the first transformation step, which is used to insert the counterselection cassette at the mutation site on the chromosome. In the current study, we develop a next-generation counterselection cassette that eliminates 4-CP background resistance and combine this with a new direct repeat-mediated cloning-independent markerless mutagenesis (DR-CIMM) system to specifically address the limitations of the prior approach. DR-CIMM is even faster and more efficient than CIMM for the creation of all types of deletions, insertions, and point mutations and is similarly adaptable for use in a wide range of genetically tractable bacteria.
Mathenjwa, Thulile; Maharaj, Pranitha
2012-10-01
To explore commercial sex workers' experiences with the female condom in Swaziland. This is a qualitative study that draws on two focus group discussions and ten individual in-depth interviews with female commercial sex workers in Lavumisa, Swaziland. The findings suggest that the majority of female sex workers prefer to use the female condom with their clients because it offers them greater control over the sexual encounter. Other factors that facilitate its use include the absence of side effects, the enhancement of sexual pleasure and protection against the risk of STIs (including HIV). In addition, the women reported that the female condom is stronger and more resistant to breakage than the male condom. Moreover, the female condoms can be inserted well in advance of sexual intercourse. Difficulties of insertion, partner objection and limited product availability were some of the barriers to the use of the device. There was also a tendency to reuse the female condoms because of lack of product availability and privacy to insert it. Although female condom use involves negotiation with clients, the fact that it offers sex workers an independent method of protection gives them more power and also, increases their ability to control their sexual and reproductive health.
Technical Errors May Affect Accuracy of Torque Limiter in Locking Plate Osteosynthesis.
Savin, David D; Lee, Simon; Bohnenkamp, Frank C; Pastor, Andrew; Garapati, Rajeev; Goldberg, Benjamin A
2016-01-01
In locking plate osteosynthesis, proper surgical technique is crucial in reducing potential pitfalls, and use of a torque limiter makes it possible to control insertion torque. We conducted a study of the ways in which different techniques can alter the accuracy of torque limiters. We tested 22 torque limiters (1.5 Nm) for accuracy using hand and power tools under different rotational scenarios: hand power at low and high velocity and drill power at low and high velocity. We recorded the maximum torque reached after each torque-limiting event. Use of torque limiters under hand power at low velocity and high velocity resulted in significantly (P < .0001) different mean (SD) measurements: 1.49 (0.15) Nm and 3.73 (0.79) Nm. Use under drill power at controlled low velocity and at high velocity also resulted in significantly (P < .0001) different mean (SD) measurements: 1.47 (0.14) Nm and 5.37 (0.90) Nm. Maximum single measurement obtained was 9.0 Nm using drill power at high velocity. Locking screw insertion with improper technique may result in higher than expected torque and subsequent complications. For torque limiters, the most reliable technique involves hand power at slow velocity or drill power with careful control of insertion speed until 1 torque-limiting event occurs.
Strategies to improve electrode positioning and safety in cochlear implants.
Rebscher, S J; Heilmann, M; Bruszewski, W; Talbot, N H; Snyder, R L; Merzenich, M M
1999-03-01
An injection-molded internal supporting rib has been produced to control the flexibility of silicone rubber encapsulated electrodes designed to electrically stimulate the auditory nerve in human subjects with severe to profound hearing loss. The rib molding dies, and molds for silicone rubber encapsulation of the electrode, were designed and machined using AutoCad and MasterCam software packages in a PC environment. After molding, the prototype plastic ribs were iteratively modified based on observations of the performance of the rib/silicone composite insert in a clear plastic model of the human scala tympani cavity. The rib-based electrodes were reliably inserted farther into these models, required less insertion force and were positioned closer to the target auditory neural elements than currently available cochlear implant electrodes. With further design improvements the injection-molded rib may also function to accurately support metal stimulating contacts and wire leads during assembly to significantly increase the manufacturing efficiency of these devices. This method to reliably control the mechanical properties of miniature implantable devices with multiple electrical leads may be valuable in other areas of biomedical device design.
Zou, Huachun; Prestage, Garrett; Fairley, Christopher K; Grulich, Andrew E; Garland, Suzanne M; Hocking, Jane S; Bradshaw, Catriona S; Cornall, Alyssa M; Tabrizi, Sepehr N; Morrow, Andrea; Chen, Marcus Y
2014-08-01
To report on sexual behaviors and sexually transmitted infections (STIs) among men who have sex with men (MSM) in their teens, when many MSM engage in their first sexual experiences. MSM aged 16 to 20 years were recruited via community and other sources. Men completed a questionnaire about their sexual behaviors and were screened for gonorrhea, chlamydia, syphilis, and HIV. Two hundred men were included. The median age was 19 years. The median age at first insertive or receptive anal intercourse was 17 years. Half of men reported sex with mainly older men: these men were more likely to engage in receptive anal intercourse (48% vs. 25%, p < .001) than other men. Most men had engaged in insertive (87%) and receptive (85%) anal intercourse in the prior 12 months with 60% and 53% reporting inconsistent condom use with insertive and receptive anal intercourse partners, respectively. The median number of insertive anal intercourse partners was 3 and 1.5 (p < .001) among men reporting inconsistent and consistent condom use with insertive anal intercourse over the prior 12 months. The median number of receptive anal intercourse partners was 3 and 2 (p = .006) among men reporting inconsistent and consistent condom use with receptive anal intercourse over the prior 12 months. Pharyngeal gonorrhea, rectal gonorrhea, urethral chlamydia, rectal chlamydia, and syphilis were detected in 3.0%, 5.5%, 3.0%, 4%, and 2.0% of men, respectively. All men were HIV negative. Many of the teenage MSM in this study were at risk for STI. Preventative messages and STI screening interventions that are age appropriate need to be developed to reduce HIV and STI risk in this under-recognized group. Copyright © 2014 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Kasaro, Margaret P; Husnik, Marla J; Chi, Benjamin H; Reid, Cheri; Magure, Tsitsi; Makanani, Bonus; Tembo, Tchangani; Ramjee, Gita; Maslankowski, Lisa; Rabe, Lorna; Brad Guffey, M
2017-04-01
The objective of this study was to describe the impact of intense counseling to reduce vaginal hygiene practices and its effect on bacterial vaginosis. A secondary data analysis of the HIV Prevention Trials Network 035 study was undertaken, focusing on HIV-negative, nonpregnant women who were at least 18 years old, in seven African sites and one US site. At enrollment and during follow-up quarterly visits, vaginal hygiene practices were determined by face-to-face administration of a behavioral assessment questionnaire. Vaginal hygiene practices were categorized as insertion into the vagina of (1) nothing, (2) water only, and (3) other substances with or without water. Each practice was quantified by frequency and type/combination of inserted substances. At quarterly visits, diagnosis of bacterial vaginosis was made using the Nugent score. Trends for vaginal hygiene practices and bacterial vaginosis were evaluated using generalized estimating equation models. A total of 3087 participants from the HIV Prevention Trials Network 035 study were eligible for this analysis. At enrollment, 1859 (60%) reported recent vaginal hygiene practices. By one year, this figure had decreased to 1019 (33%) with counseling. However, bacterial vaginosis prevalence remained consistent across the study observation period, with 36%-38% of women testing positive for the condition ( p for trend = 0.27). Overall, those who reported douching with water only (AOR = 1.03, 95%CI: 0.94-1.13) and those who reported inserting other substances (AOR= 0.98, 95%CI: 0.88-1.09) in the past quarter were not more likely to have bacterial vaginosis compared to those who reported no insertions. However, in South Africa, an increase in bacterial vaginosis was seen among those who reported inserting other substances (AOR: 1.48, 95%CI: 1.17, 1.88). In conclusion, targeted counseling against vaginal hygiene practices resulted in change in self-reported behavior but did not have an impact on bacterial vaginosis diagnosis in all but one site.
Skin microdialysis coupled with laser speckle contrast imaging to assess microvascular reactivity.
Cracowski, J L; Gaillard-Bigot, F; Cracowski, C; Roustit, M; Millet, C
2011-11-01
Laser speckle contrast imaging (LSCI) can be used to assess real-time responses of skin microcirculation to pharmacological interventions. The main objective of this study was to determine whether intradermal or subdermal microdialysis fiber insertion, coupled with skin flux recording using LSCI, can be used to assess baseline cutaneous flux and the post-occlusive reactive hyperemic response. The microdialysis sites were compared to control area without microdialysis fibers. One dermal and two subdermal microdialysis fibers were randomly inserted in the right forearm skin of six healthy volunteers. We performed consecutively tests of post-occlusive hyperemia, infusion of 29 mM sodium nitroprusside (SNP), local thermal hyperemia at 43°C and a second 29 mM SNP infusion at the end of the experiment. Two hours after fiber insertion, cutaneous vascular conductances (CVC) at the subdermal fiber sites were not different from their respective control regions of interest, while at the dermal site CVC remained higher (0.48+/-0.15 versus 0.37+/-0.1 PU.mm Hg(-1), P=0.003). The peak CVC and area under the curve observed during post-occlusive reactive hyperemia were similar at all fiber sites and their respective controls. We observed a similar increase in CVC using 29 mM SNP infusion, 40 min local heating at 43°C, and their combination. Finally, physiological and pharmacological responses of the subdermal sites were reproducible in terms of amplitude, whether expressed as raw CVC or as % CVCmax. We showed that studying skin microvascular physiological or pharmacological responses using inserted subdermal microdialysis fibers coupled with LSCI is feasible and reproducible, and provides two-dimensional information. This technique will be useful for future mechanistic studies of skin microcirculation. Copyright © 2011 Elsevier Inc. All rights reserved.
Quirin, Christina; Rohmer, Stanimira; Fernández-Ulibarri, Inés; Behr, Michael; Hesse, Andrea; Engelhardt, Sarah; Erbs, Philippe; Enk, Alexander H.
2011-01-01
Abstract Key challenges facing cancer therapy are the development of tumor-specific drugs and potent multimodal regimens. Oncolytic adenoviruses possess the potential to realize both aims by restricting virus replication to tumors and inserting therapeutic genes into the virus genome, respectively. A major effort in this regard is to express transgenes in a tumor-specific manner without affecting virus replication. Using both luciferase as a sensitive reporter and genetic prodrug activation, we show that promoter control of E1A facilitates highly selective expression of transgenes inserted into the late transcription unit. This, however, required multistep optimization of late transgene expression. Transgene insertion via internal ribosome entry site (IRES), splice acceptor (SA), or viral 2A sequences resulted in replication-dependent expression. Unexpectedly, analyses in appropriate substrates and with matching control viruses revealed that IRES and SA, but not 2A, facilitated indirect transgene targeting via tyrosinase promoter control of E1A. Transgene expression via SA was more selective (up to 1,500-fold) but less effective than via IRES. Notably, we also revealed transgene-dependent interference with splicing. Hence, the prodrug convertase FCU1 (a cytosine deaminase–uracil phosphoribosyltransferase fusion protein) was expressed only after optimizing the sequence surrounding the SA site and mutating a cryptic splice site within the transgene. The resulting tyrosinase promoter-regulated and FCU1-encoding adenovirus combined effective oncolysis with targeted prodrug activation therapy of melanoma. Thus, prodrug activation showed potent bystander killing and increased cytotoxicity of the virus up to 10-fold. We conclude that armed oncolytic viruses can be improved substantially by comparing and optimizing strategies for targeted transgene expression, thereby implementing selective and multimodal cancer therapies. PMID:20939692
Moskowitz, David A.; Seal, David W.
2014-01-01
Research suggests that self-esteem in gay and bisexual men may be linked with sexual risk-taking behaviors. As part of a larger investigation into the sexual practices of gay and bisexual men, we assessed serostatus, self-esteem, condom use, and HIV disclosure to sexual partners. Among HIV-negative men, no relationships were found between their self-esteem and tendency to discuss their and their partners’ HIV status. However, among HIV-positive men, there was a positive relationship between self-esteem and disclosure to receptive and insertive anal sex partners. These results suggest greater attention to the self-esteem of HIV-positive men by attending healthcare workers and social support groups. PMID:20352316
Freinkman, Elizaveta; Chng, Shu-Sin; Kahne, Daniel
2011-02-08
The cell surfaces of Gram-negative bacteria are composed of lipopolysaccharide (LPS). This glycolipid is found exclusively in the outer leaflet of the asymmetric outer membrane (OM), where it forms a barrier to the entry of toxic hydrophobic molecules into the cell. LPS typically contains six fatty acyl chains and up to several hundred sugar residues. It is biosynthesized in the cytosol and must then be transported across two membranes and an aqueous intermembrane space to the cell surface. These processes are required for the viability of most Gram-negative organisms. The integral membrane β-barrel LptD and the lipoprotein LptE form an essential complex in the OM, which is necessary for LPS assembly. It is not known how this complex translocates large, amphipathic LPS molecules across the OM to the outer leaflet. Here, we show that LptE resides within the LptD β-barrel both in vitro and in vivo. LptD/E associate via an extensive interface; in one specific interaction, LptE contacts a predicted extracellular loop of LptD through the lumen of the β-barrel. Disrupting this interaction site compromises the biogenesis of LptD. This unprecedented two-protein plug-and-barrel architecture suggests how LptD/E can insert LPS from the periplasm directly into the outer leaflet of the OM to establish the asymmetry of the bilayer.
Carballo-Diéguez, A; Dolezal, C; Bauermeister, J A; O'Brien, W; Ventuneac, A; Mayer, K
2008-11-01
To assess whether men who have sex with men (MSM) prefer a gel or a suppository as a delivery vehicle for a rectal microbicide. 77 HIV-negative MSM with a recent history of inconsistent condom use during receptive anal intercourse (RAI) who acknowledged being at risk of contracting HIV were enrolled in a randomised, crossover acceptability trial. They compared 35 ml placebo gel with 8 g placebo rectal suppositories used on up to three RAI occasions each. Participants preferred the gel over the suppository (75% versus 25%, p<0.001) and so did their partners (71% versus 29%, p<0.001). The gel received more favourable ratings overall and on attributes such as colour, smell, consistency, feeling in rectum immediately after insertion and/or 30 minutes after insertion and application process. The gel resulted in less negative ratings in terms of participants being bothered by leakage, soiling, bloating, gassiness, stomach cramps, urge to have bowel movement, diarrhoea, pain or trauma. Participants liked the gel more in terms of feelings during anal sex, sexual satisfaction, partners' sexual satisfaction and liking the product when condoms were used and when condoms were not used. In this sample taken from one of the populations most likely to benefit from rectal microbicide availability, gel had greater acceptability than a suppository as a potential microbicide vehicle.
Allan-Blitz, Lao-Tzu; Leon, Segundo R; Bristow, Claire C; Konda, Kelika A; Vargas, Silver K; Flores, Juan A; Brown, Brandon J; Caceres, Carlos F; Klausner, Jeffrey D
2017-02-01
Chlamydia trachomatis and Neisseria gonorrhoeae are among the most common sexually transmitted bacterial infections in the world. Data are limited, however, on the burden of extra-genital chlamydial and gonococcal infections among men who have sex with men and transgender women in Lima, Peru. Data were gathered from self-collected anal or pharyngeal swabs from participants in Lima, Peru, and analyzed via cross-sectional methods. Prevalence ratios for the association between extra-genital infection with socio-demographic and sexual behaviors were determined. Overall, 127 (32.8%) participants had anal or pharyngeal infections. On multivariate modeling, anal infection was positively associated with practicing both receptive and insertive anal sex, when compared to insertive alone (PR = 2.49; 95% CI = 1.32-4.71), and negatively associated with any antibiotic use in the prior three months (PR = 0.60; 95% CI = 0.39-0.91). Pharyngeal infection was negatively associated with age greater than 30 years compared to 18-30 years (PR = 0.54; 95% CI = 0.30-0.96), and positively associated with gender identity of transgender women (PR = 2.12; 95% CI = 1.20-3.73). This study demonstrates considerable burden of extra-genital chlamydial and gonococcal infections among men who have sex with men and transgender women in Lima, Peru.
2006-06-27
INTRODUCTION Burkholderia mallei is the etiological agent of glanders and a highly evolved obligate zoonotic mammalian pathogen that naturally affects horses...mini-Tn7 insertion in bacteria with multiple glmS-linked attTn7 sites: example Burkholderia mallei ATCC 23344 Kyoung-Hee Choi1, David DeShazer2... glanders is a rare disease, B. mallei has received renewed attention because of its listing as a category B agent by the Centers for Disease Control
Study to Expand Simulation Cockpit Displays of Advanced Sensors
1981-03-01
common source is being used for multiple sensor types). If inde- pendent displays and controls are desired then two independent video sources or sensor...line is inserted in each gap, the result is the familiar 211 in- terlace. If two lines are inserted, the result is 31l interlace, and so on. The total...symbol generators. If these systems are oper- ating at various scan rates and if a common display device, such as a multifunction display (MFD) is to
All-fiber Devices Based on Photonic Crystal Fibers with Integrated Electrodes
NASA Astrophysics Data System (ADS)
Chesini, Giancarlo; Cordeiro, Cristiano M. B.; de Matos, Christiano J. S.; Fokine, Michael; Carvalho, Isabel C. S.; Knighf, Jonathan C.
2008-10-01
A special kind of microstructured optical fiber was proposed and manufactured where, as well as the holey region (solid core and silica-air cladding), the fiber has also two large holes for electrode insertion. Bi-Sn and Au-Sn alloys were selectively inserted in those holes forming two parallel, continuous and homogeneous internal electrodes. We demonstrated the production of a monolithic device and its use to externally control some of the guidance properties (e.g. polarization) of the fiber.
Ranganathan, Dwarakanathan; John, George T; Yeoh, Edward; Williams, Nicola; O'Loughlin, Barry; Han, Thin; Jeyaseelan, Lakshmanan; Ramanathan, Kavitha; Healy, Helen
2017-01-01
The optimal time for the commencement of peritoneal dialysis (PD) after PD catheter insertion is unclear. If dialysis is started too soon after insertion, dialysate leaks and infection could occur. However, by starting PD earlier, morbidity and costs can be reduced through lesser hemodialysis requirements. This is the first randomized controlled trial to determine the safest and shortest interval to commence PD after catheter insertion. All consecutive patients undergoing PD catheter insertion at the Royal Brisbane and Women's Hospital and Rockhampton Hospital from 1 March 2008 to 31 May 2013 who met the inclusion and exclusion criteria were invited to participate in the trial. Participants were randomized to 1 of 3 groups. Group 1 (G1) commenced PD at 1 week, group 2 (G2) at 2 weeks and group 3 (G3) at 4 weeks after PD catheter insertion. These groups were stratified by hospital and the presence of diabetes. Primary outcomes were the incidence of peritoneal fluid leaks or PD-related infection during the 4 weeks after commencement of PD. In total 122 participants were recruited, 39, 42, and 41 randomized to G1, G2, and G3, respectively. The primary outcome catheter leak was significantly higher in G1 (28.2%) compared with G3 (2.4%, p = 0.001) but not compared with G2 (9.5%, p = 0.044), based on intention to treat analysis. These differences were even more marked when analyzed with per protocol method: G1 had a significantly higher percentage (32.4 %) compared with G3 (3.3%, p = 0.003) but not compared with G2 (10.5%, p = 0.040). Event percentages of leak were statistically higher in G1 and occurred significantly earlier compared with other groups ( p = 0.002). Amongst diabetics, technique failure was significantly higher (28.6%) in G3 compared with 0% in G1 and 7.1% in G2 ( p = 0.036) and earlier in G3 at 163.2 days vs 176.8 and 175.8 ( p = 0.037) for G1 and G2, respectively. Leaks were higher in participants commencing PD at 1 week after catheter insertion compared with the other 2 groups, and technique failure was higher in diabetics starting PD at 4 weeks. Copyright © 2017 International Society for Peritoneal Dialysis.
Whitehead, Ashley E; Parreira, Valeria R; Hewson, Joanne; Watson, Johanna L; Prescott, John F
2012-01-15
Pneumonia caused by Rhodococcus equi remains a significant problem in foals. The objective of this study was to develop a safe and efficacious attenuated strain of R. equi for eventual use in oral immunization of foals. The approach involved expression of vapA in a live, virulence plasmid-negative, strain of R. equi (strain 103-). PCR-amplified fragments of the vapA gene, with and without the upstream genes virR, orf5, vapH, orf7 and orf8 (orf4-8), were cloned into a shuttle vector pNBV1. These plasmids, named pAW48A and pAWVapA respectively, were electroporated into strain 103-. The presence of the recombinant vectors in the attenuated strain (103-) and the integrity of the inserted genes were confirmed, and both constructs expressed VapA. The virulence of the two strains was compared to that of wild type R. equi 103+ and negative controls by their intravenous inoculation into mice, followed by examination of liver clearance 4 days later. Mice inoculated with R. equi 103-, 103-/pAWVapA and 103-/pNBV1 completely cleared infection, whereas strain 103-/pAW48A persisted in 47% of mice. Copyright © 2011 Elsevier B.V. All rights reserved.
Behnke, Michael S; Khan, Asis; Sibley, L David
2015-02-01
Quantitative trait locus (QTL) mapping studies have been integral in identifying and understanding virulence mechanisms in the parasite Toxoplasma gondii. In this study, we interrogated a different phenotype by mapping sinefungin (SNF) resistance in the genetic cross between type 2 ME49-FUDR(r) and type 10 VAND-SNF(r). The genetic map of this cross was generated by whole-genome sequencing of the progeny and subsequent identification of single nucleotide polymorphisms (SNPs) inherited from the parents. Based on this high-density genetic map, we were able to pinpoint the sinefungin resistance phenotype to one significant locus on chromosome IX. Within this locus, a single nonsynonymous SNP (nsSNP) resulting in an early stop codon in the TGVAND_290860 gene was identified, occurring only in the sinefungin-resistant progeny. Using CRISPR/CAS9, we were able to confirm that targeted disruption of TGVAND_290860 renders parasites sinefungin resistant. Because disruption of the SNR1 gene confers resistance, we also show that it can be used as a negative selectable marker to insert either a positive drug selection cassette or a heterologous reporter. These data demonstrate the power of combining classical genetic mapping, whole-genome sequencing, and CRISPR-mediated gene disruption for combined forward and reverse genetic strategies in T. gondii. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Managing a chest tube and drainage system.
Durai, Rajaraman; Hoque, Happy; Davies, Tony W
2010-02-01
Intercostal drainage tubes (ie, chest tubes) are inserted to drain the pleural cavity of air, blood, pus, or lymph. The water-seal container connected to the chest tube allows one-way movement of air and liquid from the pleural cavity. The container should not be changed unless it is full, and the chest tube should not be clamped unnecessarily. After a chest tube is inserted, a nurse trained in chest-tube management is responsible for managing the chest tube and drainage system. This entails monitoring the chest-tube position, controlling fluid evacuation, identifying when to change or empty the containers, and caring for the tube and drainage system during patient transport. This article provides an overview of indications, insertion techniques, and management of chest tubes. Copyright 2010 AORN, Inc. Published by Elsevier Inc. All rights reserved.
Walker, D.E.; Matras, S.
1963-04-30
This patent shows a method of making a fuel or control rod for a nuclear reactor. Fuel or control material is placed within a tube and plugs of porous metal wool are inserted at both ends. The metal wool is then compacted and the tube compressed around it as by swaging, thereby making the plugs liquid- impervious but gas-pervious. (AEC)
Code of Federal Regulations, 2010 CFR
2010-10-01
... Control Act Confidential Business Information (APR 1996). 1552.235-75 Section 1552.235-75 Federal... Confidential Business Information (APR 1996). As prescribed in 1535.007(b), insert the following provision: Access to Toxic Substances Control Act Confidential Business Information (APR 1996) In order to perform...
Variable-thermoinsulation garments with a microprocessor temperature controller.
Kurczewska, Agnieszka; Leánikowski, Jacek
2008-01-01
This paper presents the concept of active variable thermoinsulation clothing for users working in low temperatures. Those garments contain heating inserts regulated by a microprocessor temperature controller. This paper also presents the results of tests carried out on the newly designed garments.
Schmitt, Christian M; Koepple, Markus; Moest, Tobias; Neumann, Konrad; Weisel, Tamara; Schlegel, Karl Andreas
2016-11-01
The overall aim of the study was to investigate a biofunctionalized implant surface with electrochemically deposition of hydroxyapatite and the synthetic peptide (P-15) and its effect on osseointegration. Three modified implant types of ANKYLOS ® C/X implants were used; (1) machined implants used as negative control (M, n = 20), (2) implants with the FRIADENT ® plus surface (grit blasted and acid-etched) used as positive control (P, n = 20), and (3) implants with a biomimetic surface consisting of hydroxyapatite and the synthetic 15 aminoacids containing peptide P-15 (BP, n = 40). The implants were randomly inserted in the mandibles of 10 beagle dogs following 4 months after tooth extraction (P1-P4). Three animals were sacrificed 2 and 7 days after implant insertion, respectively, and four animals were sacrificed 6 months post implant insertion. Bone-to-implant contacts (BICs) were analyzed via histomorphometrical analyses at five different region of interests (ROIs); two at the middle part on either side of the implant (ROI 1/4), two at the apical part of the implant at each side (ROI 2/3), and one at the tip of the implant (ROI 5). All implant surfaces showed a high level of osseointegration and osteoconductivity. The cumulative implant survival rate (CSR) was 93.8%, 100% in the M, 85% in the P, and 95% in the BP group. No statistical difference in BICs at ROI 1/4, 2/3, and 5 could be shown between implant types following 2 and 7 days of healing. BIC values increased in all groups over time. After 6 months of healing the BP group showed superiority in BIC in ROI 2/3 (73.2 ± 15.6%) compared to the P (48.3 ± 10.6%) and M group (66.3 ± 30.2%) with a significant difference between BP and P (P = 0.002). It is hypothesized, that the surface biofunctionalization improves peri-implant bone formation and remodeling, leading to an increased bone-to implant contact. However, within the limitations of the study set-up no benefit in the early phase of osseointegration could be established for dental implants with P-15 containing surface in this study. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Miikkulainen, Ville; Rasilainen, Tiina; Puukilainen, Esa; Suvanto, Mika; Pakkanen, Tapani A
2008-05-06
The wetting properties of polypropylene (PP) surfaces were modified by adjusting the dimensions of the surface nanostructure. The nanostructures were generated by injection molding with nanoporous anodized aluminum oxide (AAO) as the mold insert. Atomic layer deposition (ALD) of molybdenum nitride film was used to control the pore diameters of the AAO inserts. The original 50-nm pore diameter of AAO was adjusted by depositing films of thickness 5, 10, and 15 nm on AAO. Bis(tert-butylimido)-bis(dimethylamido)molybdenum and ammonia were used as precursors in deposition. The resulting pore diameters in the nitride-coated AAO inserts were 40, 30, and 20 nm, respectively. Injection molding of PP was conducted with the coated inserts, as well as with the non-coated insert. Besides the pore diameter, the injection mold temperature was varied with temperatures of 50, 70, and 90 degrees C tested. Water contact angles of PP casts were measured and compared with theoretical contact angles calculated from Wenzel and Cassie-Baxter theories. The highest contact angle, 140 degrees , was observed for PP molded with the AAO mold insert with 30-nm pore diameter. The Cassie-Baxter theory showed better fit than the Wenzel theory to the experimental values. With the optimal AAO mask, the nanofeatures in the molded PP pieces were 100 nm high. In explanation of this finding, it is suggested that some sticking and stretching of the nanofeatures occurs during the molding. Increase in the mold temperature increased the contact angle.
Torque Loss After Miniscrew Placement: An In-Vitro Study Followed by a Clinical Trial.
Migliorati, Marco; Drago, Sara; Barberis, Fabrizio; Schiavetti, Irene; Dalessandri, Domenico; Benedicenti, Stefano; Biavati, Armando Silvestrini
2016-01-01
To evaluate torque loss a week after insertion, both in an in vivo and an in vitro experimental setup were designed. In the in vivo setup a total of 29 miniscrews were placed in 20 patients who underwent orthodontic treatment. Maximum insertion torque (MIT) was evaluated at insertion time (T1). A week later, insertion torque was measured again by applying a quarter turn (T2); no load was applied on the screw during the first week. In the in vitro setup a total of 20 miniscrews were placed in pig rib bone samples. MIT was evaluated at insertion time (T1). Bone samples were kept in saline solution and controlled environment for a week during which the solution was refreshed every day. Afterwards, torque was measured again by applying a quarter turn (T2). The comparison of MIT over time was done calculating the percentage difference of the torque values between pre- and post-treatment and using the parametric two independent samples t-test or the non-parametric Mann-Whitney test. After a week unloaded miniscrews showed a mean loss of rotational torque of 36.3% and 40.9% in in vitro and in in vivo conditions, respectively. No statistical differences were found between the two different setups. Torque loss was observed after the first week in both study models; in vitro experimental setup provided a reliable study model for studying torque variation during the first week after insertion.
Torque Loss After Miniscrew Placement: An In-Vitro Study Followed by a Clinical Trial
Migliorati, Marco; Drago, Sara; Barberis, Fabrizio; Schiavetti, Irene; Dalessandri, Domenico; Benedicenti, Stefano; Biavati, Armando Silvestrini
2016-01-01
To evaluate torque loss a week after insertion, both in an in vivo and an in vitro experimental setup were designed. In the in vivo setup a total of 29 miniscrews were placed in 20 patients who underwent orthodontic treatment. Maximum insertion torque (MIT) was evaluated at insertion time (T1). A week later, insertion torque was measured again by applying a quarter turn (T2); no load was applied on the screw during the first week. In the in vitro setup a total of 20 miniscrews were placed in pig rib bone samples. MIT was evaluated at insertion time (T1). Bone samples were kept in saline solution and controlled environment for a week during which the solution was refreshed every day. Afterwards, torque was measured again by applying a quarter turn (T2). The comparison of MIT over time was done calculating the percentage difference of the torque values between pre- and post-treatment and using the parametric two independent samples t-test or the non-parametric Mann–Whitney test. After a week unloaded miniscrews showed a mean loss of rotational torque of 36.3% and 40.9% in in vitro and in in vivo conditions, respectively. No statistical differences were found between the two different setups. Torque loss was observed after the first week in both study models; in vitro experimental setup provided a reliable study model for studying torque variation during the first week after insertion. PMID:27386011
Occurence of adverse events due to continuous glucose monitoring.
Jadviscokova, Tereza; Fajkusova, Zuzana; Pallayova, Maria; Luza, Jiri; Kuzmina, Galina
2007-12-01
Continuous glucose monitoring (CGM) using transcutaneous sensors is becoming a sophisticated method to control and regulate glucose metabolism. The transcutaneous sensor of the CGM system (CGMS Medtronic Minimed, Northridge, CA, USA) is chosen to measure glucose concentration in interstitial fluid up to three days after insertion even though its function remains stable for a longer period. The question arises, which factors really limit the period of sensor insertion without unnecessary risk. The aim of this study was to assess any adverse events occurring in the course of 9 days after the sensor insertion. In a group of 22 healthy volunteers aged 21.8+/-1.30 y (mean +/- SE) a total of 26 sensors was inserted subcutaneously in gluteal or lumbar region for 9 days. Before insertion the site was sprayed with an antiseptic (Cutasept F, Bode Chemie, Hamburg, Germany). Local adverse reactions and disturbances in general condition were examined. In the course of 184 sensor-days, there were only minor local adverse events: hypersensitivity, itching, pain, redness, burning, subcutaneous hemorrhage. Additionally, sleep disturbances, attention deficits, problems related to the CGMS monitor, to adhesive tape and/or sensor were found. None of these resulted in sensor withdrawal. In 12 volunteers (55 %) no complications were observed. The sensor function measured according to electrical signals (ISIG) failed (always on day 1-2) in 4 cases (16 %). The present FDA approved 3-day insertion period for Medtronic transcutaneous sensor does not seem to limit its use and appears to be worth a careful revision.
Komatsu, R.; Nagata, O.; Kamata, K.; Yamagata, K.; Sessler, D.I.; Ozaki, M.
2005-01-01
Summary We compared the usefulness of the laryngeal tube (LT) with the intubating laryngeal mask airway (ILMA) in 51 patients whose necks were stabilised by manual in-line traction. After induction of anaesthesia and neuromuscular block, the LT and ILMA were inserted consecutively in a randomised, crossover design. During pressure-controlled ventilation (20 cmH2O inspiratory pressure), we measured insertion attempts, time to establish positive-pressure ventilation, tidal volume, gastric insufflation, and minimum airway pressure at which gas leaked around the cuff. Data were compared using Wilcoxon signed-rank tests; P<0.05 was considered significant. Insertion was more difficult with the LT (successful at first attempt in 16 patients) than with the ILMA (successful at first attempt in 42 patients, P<0.0001). Time required for insertion was longer for the LT (28 [23–35] sec, median [interquartile range]) than the ILMA (20 [15–25] sec, P=0.0009). Tidal volume was less for the LT (440 [290–670] ml) than the ILMA. (630 [440–750] ml, P=0.013). Minimum airway pressure at which gas leak occurred and incidence of gastric insufflation were similar with two devices. In patients whose necks were stabilised with manual in-line traction, insertion of the ILMA was easier and quicker than insertion of the LT and tidal volume was greater with the ILMA than the LT. PMID:15644005
Verdin, E; Kobisch, M; Bové, J M; Garnier, M; Saillard, C
2000-12-01
We have previously reported a nested PCR assay for the detection of Mycoplasma hyopneumoniae directly in tracheobronchiolar washings from living pigs in field conditions. Here, we describe the construction and use of an internal control to monitor the presence of PCR inhibitors. A PCR modified target DNA was constructed by insertion of a small DNA fragment into the M. hyopneumoniae specific DNA target. We have demonstrated that the internal control failed to be amplified in only three tracheobronchiolar washings samples out of the 362 tested. This control molecule was inserted in a Spiroplasma citri derived plasmid vector and introduced into S. citri cells by electroporation. After a few passages we ensured that the recombinant plasmid became inserted into the genome of S. citri. PCR amplification of the DNA of this transformed S. citri strain using nested PCR primers led to amplification of a 900-bp fragment which can be discriminated from the M. hyopneumoniae PCR product 700 bp. The S. citri transformants with the integrated internal control were added to the tracheobronchiolar washings prior to PCR and used as an internal control to check the efficiency of sample processing, and to demonstrate the presence of inhibitors. Furthermore, we have been able to estimate the number of mycoplasma cells in the tracheobronchiolar washings. Quantitation was performed by comparing the PCR signal intensity of the specific M. hyopneumoniae template with known concentrations of the S. citri competitor. The titer in tracheobronchiolar washings ranged approximatively from 10(4)to 10(8)M. hyopneumoniae cells per ml of clinical specimen. Quantitative PCR can be a useful tool for monitoring the progression of M. hyopneumoniae in the disease process. Copyright 2000 Academic Press.
Rajgopal, Ashok; Aggarwal, Kalpana; Khurana, Anshika; Rao, Arun; Vasdev, Attique; Pandit, Hemant
2017-01-01
Total knee arthroplasty is a well-established treatment for managing end-stage symptomatic knee osteoarthritis. Currently, different designs of prostheses are available with majority ensuring similar clinical outcomes. Altered surface geometry is introduced to strive toward gaining superior outcomes. We aimed to investigate any differences in functional outcomes between 2 different polyethylene designs namely the Persona CR (cruciate retaining) and Persona UC (ultracongruent) tibial inserts (Zimmer-Biomet, Warsaw, IN). This prospective single blind, single-surgeon randomized controlled trial reports on 105 patients, (66 female and 39 male), who underwent simultaneous bilateral total knee arthroplasty using the Persona knee system (Zimmer-Biomet) UC inserts in one side and CR inserts in the contralateral side. By a blind assessor, at regular time intervals patients were assessed in terms of function and gait. The functional knee scoring scales used were the Western Ontario and McMaster Universities Osteoarthritis Index and Modified Knee Society Score. The gait parameters evaluated were foot pressure and step length. During the study period, no patient was lost to follow-up or underwent revision surgery for any cause. Western Ontario and McMaster Universities Osteoarthritis Index scores, Modified Knee Society Score, and knee range of motion of all 105 patients assessed preoperatively and postoperatively at 6 months, 1 year, and 2 years showed statistically better results (P < .05) for UC inserts. Gait analysis measuring foot pressures and step length, however, did not show any statistically significant differences at 2-year follow-up. Ultracongruent tibial inserts show significantly better functional outcomes as compared to CR inserts during a 2-year follow-up period. However, in this study these findings were not shown to be attributed to differences in gait parameters. Copyright © 2016 Elsevier Inc. All rights reserved.