Sample records for installing prototype sleeves

  1. DEVELOPMENT OF PERMANENT MECHANICAL REPAIR SLEEVE FOR PLASTIC PIPE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hitesh Patadia

    2005-04-29

    The report presents a comprehensive summary of the prototype development process utilized towards the development of a permanent mechanical repair fitting intended to be installed on damaged PE mains under blowing gas conditions. Specifically, the step by step construction approach is presented and the experimental data to support the mitigation of ensuing slow crack growth (SCG) of the damage area.

  2. Installation and assembly device and method of using

    DOEpatents

    Kolsun, George J.

    1997-01-01

    An installation and assembly device for aligning a first member such as a pump impeller with a second member such as an inlet nozzle of an impeller pump. The installation and assembly device includes a sleeve slideable within the inlet nozzle and a vertical positioning assembly which has a contact member that is extendable out away from the sleeve so as to vertically position the sleeve on a shoulder of the inlet nozzle and to present an upper contact surface spaced a certain distance from the shoulder to provide the desired vertical spacing with respect to the impeller contacting the upper contact surface. The vertical positioning assembly is retractable so as to allow for removal of the sleeve through the nozzle when installation and assembly are completed. The alignment device also includes a radial alignment assembly supported by the sleeve and adjustable to an expanded state for contacting and spacing the interior surface of the impeller a certain distance from the sleeve and hence a certain distance from the inlet nozzle. The radial alignment device being adjustable from a retracted removal state to an expanded state and also being adjustable to fine tune the spacing of the impeller from the sleeve. The radial alignment device also preferably includes members that can be used to releasably secure the sleeve to the impeller.

  3. Rockbolt and installer wand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lane, W.L.; Lewis, D.L.

    1987-04-07

    A rockbolt is described for installation in a bore in the roof of an underground excavation to support the roof, the rockbolt comprising: a sleeve insertable into the bore and having an upper and a lower end; at least one port in the sleeve near the upper end; means inside the sleeve near the upper end for engaging a device for supplying hardenable binder material inserted into the sleeve, the engaging means having at least one passage therein communicating with the port to allow binder material to pass from the device through the engaging means and out the port, tomore » encase the sleeve in binder material; means for engaging the sleeve, near the lower end, to the roof face; means for engaging the sleeve near the upper end to the rock surrounding the bore and means for tensioning the rockbolt to compress the rock between the upper and lower ends.« less

  4. 77 FR 65501 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-29

    ... done. (g) Retained Replacement of Wiring, Installation of Sleeving, and Associated Actions This... requires replacing wiring for the fuel boost pumps and override pumps with new wiring, installing Teflon sleeving on the wiring, and doing associated actions; and doing repetitive inspections to detect damage of...

  5. 78 FR 10499 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-14

    ... done. (g) Retained Replacement of Wiring, Installation of Sleeving, and Associated Actions This... replacing wiring for the fuel boost pumps and override pumps with new wiring, installing Teflon sleeving on the wiring, and doing associated actions; and doing repetitive inspections to detect damage of the...

  6. Shrinkable sleeve eliminates shielding gap in RF cable

    NASA Technical Reports Server (NTRS)

    1965-01-01

    RF shielding gap between an RF cable and a multipin connector is eliminated by a sleeve assembly installed between the connector and the terminated portion of the shielding. The assembly is enclosed in a heat-shrinkable plastic sleeve which completes the continuous RF shield.

  7. 78 FR 42411 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-16

    ... rear spar, and installation of a TFE sleeve if necessary. This new AD also adds airplanes to the... sources in the auxiliary (center) fuel tank, main fuel tanks, and surge tanks caused by a wiring short or... clamp location on the rear spar, and installation of a TFE sleeve if necessary. The NPRM also proposed...

  8. Development of a system to measure local measurement conditions around textile electrodes.

    PubMed

    Kim, Saim; Oliveira, Joana; Roethlingshoefer, Lisa; Leonhard, Steffen

    2010-01-01

    The three main influence factors on the interface between textile electrode an skin are: temperature, contact pressure and relative humidity. This paper presents first results of a prototype, which measures these local measurement conditions around textile electrodes. The wearable prototype is a data acquisition system based on a microcontroller with a flexible sensor sleeve. Validation measurements included variation of ambient temperature, contact pressures and sleeve material. Results show a good correlation with data found in literature.

  9. 77 FR 66769 - Airworthiness Directives; Rolls-Royce Deutschland Ltd & Co KG Turbojet Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-07

    .... (5) If any bolt is found broken in the HPT shaft air seal sleeve, inspect the HPT stage 1 disc for...) bearing support assembly and HPT air seal sleeve bolts identified that, before installation, those bolts... assembly, high-pressure turbine (HPT) bearing support assembly, and HPT air seal sleeve. (2) If engine...

  10. Installing fiber insulation

    NASA Technical Reports Server (NTRS)

    Wang, D. S.; Warren, A. D. (Inventor)

    1980-01-01

    A method for installing fragile, high temperature insulation batting in an elongated cavity or in a resilient wire sleeve to form a resilient seal. The batting is preformed to rough dimensions and wrapped in a plastic film, the film being of a material which is fugitive at a high temperature. The film is heat sealed and trimmed to form a snugly fit skin which overlaps at least at one end to permit attachment of a pull cord. The film absorbs the tensile force of pulling the film enclosed batting through the cavity or wire mesh sleeve and is subsequently driven off by high temperature baking, leaving only the insulation in the cavity or wire mesh sleeve.

  11. Demonstration of Corrosion-Resistant Fire Hydrant Retrofits for Military Installations

    DTIC Science & Technology

    2013-10-01

    diene M-class rubber ( EPDM )/powder coated steel sleeve inserted into the top of the hy- drant barrel at the traffic breakaway allowing the seat for...The insert seat of the valve shall be made of a ethylene propylene diene M-class rubber ( EPDM )/powder coated steel sleeve in- serted into the top of...intentional water-supply contamination. The technology was installed on 90 fire hy- drants of various makes, models, and ages at Fort Leonard Wood, MO. To

  12. Status of the steam generator tube circumferential ODSCC degradation experienced at the Doel 4 plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roussel, G.

    1997-02-01

    Since the 1991 outage, the Doel Unit 4 nuclear power plant is known to be affected by circumferential outside diameter intergranular stress corrosion cracking at the hot leg tube expansion transition. Extensive non destructive examination inspections have shown the number of tubes affected by this problem as well as the size of the cracks to have been increasing for the three cycles up to 1993. As a result of the high percentage of tubes found non acceptable for continued service after the 1993 in-service inspection, about 1,700 mechanical sleeves were installed in the steam generators. During the 1994 outage, allmore » the tubes sleeved during the 1993 outage were considered as potentially cracked to some extent at the upper hydraulic transition and were therefore not acceptable for continued service. They were subsequently repaired by laser welding. Furthermore all the tubes not sleeved during the 1993 outage were considered as not acceptable for continued service and were repaired by installing laser welded sleeves. During the 1995 outage, some unexpected degradation phenomena were evidenced in the sleeved tubes. This paper summarizes the status of the circumferential ODSCC experienced in the SG tubes of the Doel 4 plant as well as the other connected degradation phenomena.« less

  13. Numerical investigation of soil plugging effect inside sleeve of cast-in-place piles driven by vibratory hammers in clays.

    PubMed

    Xiao, Yong Jie; Chen, Fu Quan; Dong, Yi Zhi

    2016-01-01

    During driving sleeve of cast-in-place piles by vibratory hammers, soils were squeezed into sleeve and then soil plugging was formed. The physic-mechanical properties of the soil plug have direct influence on the load transmission between the sleeve wall and soil plug. Nevertheless, the researches on this issue are insufficient. In this study, finite element and infinite element coupling model was introduced, through the commercial code ABAQUS, to simulate the full penetration process of the sleeve driven from the ground surface to the desired depth by applying vibratory hammers. The research results indicated that the cyclic shearing action decreases both in soil shear strength and in granular cementation force when the sleeve is driven by vibratory hammers, which leads to a partially plugged mode of the soil plug inside the sleeve. Accordingly, the penetration resistance of sleeve driven by vibratory hammers is the smallest compared to those by other installation methods. When driving the sleeve, the annular soil arches forming in the soil plug at sleeve end induce a significant rise in the internal shaft resistance. Moreover, the influence of vibration frequencies, sleeve diameters, and soil layer properties on the soil plug was investigated in detail, and at the same time improved formulas were brought forward to describe the soil plug resistance inside vibratory driven sleeve.

  14. Design of a Bottom Impermeable Barrier in Conjunction with A contaminated Site Containment Structure.

    DTIC Science & Technology

    1994-05-01

    utilizes drill bits and tubing to cut through the soil. Unlike the auger method, a slurry mixture is used to keep the drill bit clean and assist in...is applied. In the sleeve pipe method, or also called tube -a-manchette, the sleeve pipe is installed in the grout hole, and sealed in place with a...acts as a one-way valve. allowing grout out of the pipe, but not back into the sleeve. A grouting tube with double packer is used to inject the grout

  15. Extended Sleeve Products Allow Control and Monitoring of Process Fluid Flows Inside Shielding, Behind Walls and Beneath Floors - 13041

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abbott, Mark W.

    2013-07-01

    Throughout power generation, delivery and waste remediation, the ability to control process streams in difficult or impossible locations becomes increasingly necessary as the complexity of processes increases. Example applications include radioactive environments, inside concrete installations, buried in dirt, or inside a shielded or insulated pipe. In these situations, it is necessary to implement innovative solutions to tackle such issues as valve maintenance, valve control from remote locations, equipment cleaning in hazardous environments, and flow stream analysis. The Extended Sleeve family of products provides a scalable solution to tackle some of the most challenging applications in hazardous environments which require flowmore » stream control and monitoring. The Extended Sleeve family of products is defined in three groups: Extended Sleeve (ESV), Extended Bonnet (EBV) and Instrument Enclosure (IE). Each of the products provides a variation on the same requirements: to provide access to the internals of a valve, or to monitor the fluid passing through the pipeline through shielding around the process pipe. The shielding can be as simple as a grout filled pipe covering a process pipe or as complex as a concrete deck protecting a room in which the valves and pipes pass through at varying elevations. Extended Sleeves are available between roughly 30 inches and 18 feet of distance between the pipeline centerline and the top of the surface to which it mounts. The Extended Sleeve provides features such as ± 1.5 inches of adjustment between the pipeline and deck location, internal flush capabilities, automatic alignment of the internal components during assembly and integrated actuator mounting pads. The Extended Bonnet is a shorter fixed height version of the Extended Sleeve which has a removable deck flange to facilitate installation through walls, and is delivered fully assembled. The Instrument Enclosure utilizes many of the same components as an Extended Sleeve, yet allows the installation of process monitoring instruments, such as a turbidity meter to be placed in the flow stream. The basis of the design is a valve body, which, rather than having a directly mounted bonnet has lengths of concentric pipe added, which move the bonnet away from the valve body. The pipe is conceptually similar to an oil field well, with the various strings of casing, and tubing installed. Each concentric pipe provides a required function, such as the outermost pipes, the valve sleeve and penetration sleeve, which provide structural support to the deck flange. For plug valve based designs, the next inner pipe provides compression on the environmental seals at the top of the body to bonnet joint, followed by the innermost pipe which provides rotation of the plug, in the same manner as an extended stem. Ball valve ESVs have an additional pipe to provide compressive loading on the stem packing. Due to the availability of standard pipe grades and weights, the product can be configured to fit a wide array of valve sizes, and application lengths, with current designs as short as seven inches and as tall as 18 feet. Central to the design is the requirement for no special tools or downhole tools to remove parts or configure the product. Off the shelf wrenches, sockets or other hand tools are all that is required. Compared to other products historically available, this design offers a lightweight option, which, while not as rigidly stiff, can deflect compliantly under extreme seismic loading, rather than break. Application conditions vary widely, as the base product is 316 and 304 stainless steel, but utilizes 17-4PH, and other allows as needed based on the temperature range and mechanical requirements. Existing designs are installed in applications as hot as 1400 deg. F, at low pressure, and separately in highly radioactive environments. The selection of plug versus ball valve, metal versus soft seats, and the material of the seals and seats is all dependent on the application requirements. The design of the Extended Sleeve family of products provides a platform which solves a variety of accessibility problems associated with controlling process flow streams in remote, hard to reach locations in harsh environments. Installation of the equipment described has shown to allow access to flow streams that otherwise would require exceptional means to access and control. The Extended Sleeve family of products provides a scalable solution to both control and monitor process fluid flow through shielding, walls or floors when direct connection is advantageous. (authors)« less

  16. Double-Acting Sleeve Muscle Actuator for Bio-Robotic Systems.

    PubMed

    Zheng, Hao; Shen, Xiangrong

    2013-11-25

    This paper presents a new type of muscle-like actuator, namely double-acting (DA) sleeve muscle actuator, which is suitable for the actuation of biologically-inspired and biomedical robotic systems, especially those serving human-assistance purposes (prostheses, orthoses, etc .). Developed based on the traditional pneumatic muscle actuator, the new DA sleeve muscle incorporates a unique insert at the center. With the insert occupying the central portion of the internal volume, this new actuator enjoys multiple advantages relative to the traditional pneumatic muscle, including a consistent increase of force capacity over the entire range of motion, and a significant decrease of energy consumption in operation. Furthermore, the insert encompasses an additional chamber, which generates an extension force when pressurized. As such, this new actuator provides a unique bi-directional actuation capability, and, thus, has a potential to significantly simplify the design of a muscle actuator-powered robotic system. To demonstrate this new actuator concept, a prototype has been designed and fabricated, and experiments conducted on this prototype demonstrated the enhanced force capacity and the unique bi-directional actuation capability.

  17. DEVELOPMENT OF PERMANENT MECHANICAL REPAIR SLEEVE FOR PLASTIC PIPE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hitesh Patadia

    2004-09-30

    The report presents a comprehensive summary of the project status related to the development of a permanent mechanical repair fitting intended to be installed on damaged PE mains under blowing gas conditions. Specifically, the product definition has been developed taking into account relevant codes and standards and industry input. A conceptual design for the mechanical repair sleeve has been developed which meets the product definition.

  18. Vacuum-jacketed transfer line installation technique

    NASA Technical Reports Server (NTRS)

    Bowers, W. M.

    1968-01-01

    Rolling-type spacers in the form of steel balls retained in appropriate sleeves affixed at intervals to the exterior of the transfer line facilitate the installation of a vacuum-jacketed line. They act as standoffs to position the transfer line concentrically within the vacuum jacket line.

  19. Mechanical counter pressure on the arm counteracts adverse effects of hypobaric exposures

    NASA Technical Reports Server (NTRS)

    Tanaka, Kunihiko; Limberg, Ryan; Webb, Paul; Reddig, Mike; Jarvis, Christine W.; Hargens, Alan R.

    2003-01-01

    INTRODUCTION: Current space suits have limited movement due to gas pressurization during exposure to the vacuum of space. Alternatively, if pressure is applied by an elastic garment vs. pneumatic garment to produce mechanical counter pressure (MCP), several advantages are possible. In this study, we investigate local microcirculatory and other effects produced with and without a prototype MCP glove and sleeve during exposure to varying levels of vacuum. METHODS: The entire arms of eight male volunteers were studied at normal ambient pressure and during 5 min exposures to -50, -100, and -150 mm Hg with and without the MCP glove and sleeve. Pressure distribution, skin microvascular flow, and temperature were measured. RESULTS: The MCP glove and sleeve generated over 200 mm Hg on the middle finger, dorsum of the hand, and the wrist. However, pressure was significantly lower on the forearm and the upper arm. Without the glove and sleeve, only two of eight subjects tolerated -100 mm Hg. Also, no subject tolerated -150 mm Hg. However, subjects tolerated all vacuum pressures wearing the glove and sleeve. Skin microvascular flow and temperature remained within control values with the glove and sleeve at a chamber pressure of -150 mm Hg. DISCUSSION: The MCP glove and sleeve counteracts adverse effects of vacuum exposures due to lower pressure differentials. Pressure levels over the hand and wrist are similar to those of the current U.S. space suit glove and sleeve, but additional development is required to increase MCP over the forearm and upper arm.

  20. Reliability and Failure Modes of a Hybrid Ceramic Abutment Prototype.

    PubMed

    Silva, Nelson Rfa; Teixeira, Hellen S; Silveira, Lucas M; Bonfante, Estevam A; Coelho, Paulo G; Thompson, Van P

    2018-01-01

    A ceramic and metal abutment prototype was fatigue tested to determine the probability of survival at various loads. Lithium disilicate CAD-milled abutments (n = 24) were cemented to titanium sleeve inserts and then screw attached to titanium fixtures. The assembly was then embedded at a 30° angle in polymethylmethacrylate. Each (n = 24) was restored with a resin-cemented machined lithium disilicate all-ceramic central incisor crown. Single load (lingual-incisal contact) to failure was determined for three specimens. Fatigue testing (n = 21) was conducted employing the step-stress method with lingual mouth motion loading. Failures were recorded, and reliability calculations were performed using proprietary software. Probability Weibull curves were calculated with 90% confidence bounds. Fracture modes were classified with a stereomicroscope, and representative samples imaged with scanning electron microscopy. Fatigue results indicated that the limiting factor in the current design is the fatigue strength of the abutment screw, where screw fracture often leads to failure of the abutment metal sleeve and/or cracking in the implant fixture. Reliability for completion of a mission at 200 N load for 50K cycles was 0.38 (0.52% to 0.25 90% CI) and for 100K cycles was only 0.12 (0.26 to 0.05)-only 12% predicted to survive. These results are similar to those from previous studies on metal to metal abutment/fixture systems where screw failure is a limitation. No ceramic crown or ceramic abutment initiated fractures occurred, supporting the research hypothesis. The limiting factor in performance was the screw failure in the metal-to-metal connection between the prototyped abutment and the fixture, indicating that this configuration should function clinically with no abutment ceramic complications. The combined ceramic with titanium sleeve abutment prototype performance was limited by the fatigue degradation of the abutment screw. In fatigue, no ceramic crown or ceramic abutment components failed, supporting the research hypothesis with a reliability similar to that of all-metal abutment fixture systems. A lithium disilcate abutment with a Ti alloy sleeve in combination with an all-ceramic crown should be expected to function clinically in a satisfactory manner. © 2016 by the American College of Prosthodontists.

  1. Repairing pipes on the fly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-04-01

    When piping develops leaks, the natural instinct is to shut the process down, purge the lines and call in maintenance crews to make the repairs. There is, however, an alternative: on-the-fly repairs. Through the use of specialized tools, equipment and technicians, shut-off valves can be installed and leaks repaired without interrupting production. The split sleeve offers one of the simpler approaches to on-the-fly repairs. Two half cylinders with inside diameter slightly larger than the outside diameter slightly larger than the outside diameter of the pipe to be repaired are slipped over the latter some distance form the leak and looselymore » bolted together. The cylinder is then slid over the leaking area and the bolts tightened. Gaskets inside the half cylinders provide the needed seal between the pipe and the cylinder. Installing a shut-off valve in an operating pipeline requires much more specialized equipment and skills than does repairing a leak with a split sleeve. A device available from International Piping Services Co. allows a trained crew to isolate a section of pipe, drill out the isolated portion, install a blocking valve and then remove the isolation system--all while continuing to operate the pipeline at temperatures to 700 F and pressures to 700 psi. But Herb Porter, CEO of Ipsco, cautions that unlike the repairing leaks with a split sleeve, installing a blocking valve on-the-fly always demands the services of a highly trained crew.« less

  2. Installation and assembly device and method of using

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kolsun, G.J.

    1995-12-31

    The present invention relates to an installation and assembly device and method for facilitating the fitup of mating components during blind or remote installation and assembly, especially where close fitup tolerances are involved. The present invention is particularly useful for the purpose of facilitating vertical and/or radial relative positioning of a pump impeller within a mating inlet nozzle during a blind assembly wherein actual fitup cannot be observed during installation. The information within identifies just one successful application of the installation and assembly alignment device for a pump. The device, however, is not solely limited to pump assembly but canmore » be used in other cases where fitup of a sleeve inside a mating bore is required under conditions of close tolerance during a blind or remote assembly. The device is likewise not limited to circular configurations but can be used for many other shapes or configurations. Any material that can be machined and hold reasonably close tolerances can be used for the device. Also, because the sleeve position is adjusted by set screws or bolts, the concentricity can be radially biased, if required, to achieve particular alignment conditions.« less

  3. Steam generator feedwater nozzle transition piece replacement experience at Salem Unit 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patten, D.B.; Perrin, J.S.; Roberts, A.T.

    Cracking of steam generator feedwater piping adjacent to the feedwater nozzles has been a recurring problem since 1979 at Salem Unit 1 owned and operated by Public Service Electric and Gas Company. In addition to the cracking problem, erosion-corrosion at the leading edge of the feedwater nozzle thermal sleeve was also observed in 1992. To provide a long-term solution for the pipe cracking and thermal sleeve erosion-corrosion problems, a unique transition piece forging was specially designed, fabricated, and installed for each of the four steam generators during the 1995 outage. This paper discusses the design, fabrication, and installation of themore » transition piece forgings at Salem Unit 1, and the experiences gained from this project. It is believed that these experiences may help other utilities when planning similar replacements in the future.« less

  4. Simplified installation of thrust bearings

    NASA Technical Reports Server (NTRS)

    Sensenbaugh, N. D.

    1980-01-01

    Special handling sleeve, key to method of installing thrust bearings, was developed for assembling bearings on shaft of low-pressure oxygen turbo-pump. Method eliminates cooling and vacuum-drying steps which saves time, while also eliminating possibility of corrosion formation. Procedure saves energy because it requires no liquid nitrogen for cooling shaft and no natural gas or electric power for operating vacuum oven.

  5. Combined micro and macro additive manufacturing of a swirling flow coaxial phacoemulsifier sleeve with internal micro-vanes.

    PubMed

    Choi, Jae-Won; Yamashita, Masaki; Sakakibara, Jun; Kaji, Yuichi; Oshika, Tetsuro; Wicker, Ryan B

    2010-10-01

    Microstereolithography (microSL) technology can fabricate complex, three-dimensional (3D) microstructures, although microSL has difficulty producing macrostructures with micro-scale features. There are potentially many applications where 3D micro-features can benefit the overall function of the macrostructure. One such application involves a medical device called a coaxial phacoemulsifier where the tip of the phacoemulsifier is inserted into the eye through a relatively small incision and used to break the lens apart while removing the lens pieces and associated fluid from the eye through a small tube. In order to maintain the eye at a constant pressure, the phacoemulsifier also includes an irrigation solution that is injected into the eye during the procedure through a coaxial sleeve. It has been reported, however, that the impinging flow from the irrigation solution on the corneal endothelial cells in the inner eye can damage these cells during the procedure. As a result, a method for reducing the impinging flow velocities and the resulting shear stresses on the endothelial cells during this procedure was explored, including the design and development of a complex, 3D micro-vane within the sleeve. The micro-vane introduces swirl into the irrigation solution, producing a flow with rapidly dissipating flow velocities. Fabrication of the sleeve and fitting could not be accomplished using microSL alone, and thus, a two-part design was accomplished where a sleeve with the micro-vane was fabricated with microSL and a threaded fitting used to attach the sleeve to the phacoemulsifier was fabricated using an Objet Eden 333 rapid prototyping machine. The new combined device was tested within a water container using particle image velocimetry, and the results showed successful swirling flow with an ejection of the irrigation fluid through the micro-vane in three different radial directions corresponding to the three micro-vanes. As expected, the sleeve produced a swirling flow with rapidly dissipating streamwise flow velocities where the maximum measured streamwise flow velocities using the micro-vane were lower than those without the micro-vane by 2 mm from the tip where they remained at approximately 70% of those produced by the conventional sleeve as the flow continued to develop. It is believed that this new device will reduce damage to endothelial cells during cataract surgery and significantly improve patient outcomes from this procedure. This unique application demonstrates the utility of combining microSL with a macro rapid prototyping technology for fabricating a real macro-scale device with functional, 3D micro-scale features that would be difficult and costly to fabricate using alternative manufacturing methods.

  6. Foolproof quick-release locking pin

    NASA Technical Reports Server (NTRS)

    Nelson, E. P.; Othman, T. E.; Zmuda, L. J.

    1970-01-01

    Locking pin can be withdrawn only when stress on the joint is negligible. Pin consists of a forward-pointing sleeve, a spring-loaded sliding handle, and a sliding plunger. Plunger movement controls installation and withdrawal of pin.

  7. Direct vision in minimally invasive epicardial procedures: preliminary tests of prototype instrumentation.

    PubMed

    Hack, B J; Ramon, S G; Hagen, Z A; Theran, M E; Burkhardt, J D; Gillies, G T

    2015-01-01

    This study investigated the use of direct visualization to enhance minimally invasive epicardial procedures. A commercially available miniature camera was placed in a prototype subxiphoid introducer needle and bench top, in vitro and in vivo tests of system performance were made during simulated and actual attempts at pericardial access and cardio-endoscopy. This system had an unshielded field of view of 100° and a resolution of 220 × 224 pixels. When a sleeve used to maintain depth of field was slid past the distal tip of the camera probe, the field of view would decrease by ≈15° per millimetre of sleeve extension, but without loss of image quality. While tests during in vivo subxiphoid access in a porcine model revealed that the pericardial membrane was difficult to localize, the results also showed excellent resolution of the coronary arteries on the epicardial surface. These findings and potential improvements are discussed in detail.

  8. Using arm and hand gestures to command robots during stealth operations

    NASA Astrophysics Data System (ADS)

    Stoica, Adrian; Assad, Chris; Wolf, Michael; You, Ki Sung; Pavone, Marco; Huntsberger, Terry; Iwashita, Yumi

    2012-06-01

    Command of support robots by the warfighter requires intuitive interfaces to quickly communicate high degree-offreedom (DOF) information while leaving the hands unencumbered. Stealth operations rule out voice commands and vision-based gesture interpretation techniques, as they often entail silent operations at night or in other low visibility conditions. Targeted at using bio-signal inputs to set navigation and manipulation goals for the robot (say, simply by pointing), we developed a system based on an electromyography (EMG) "BioSleeve", a high density sensor array for robust, practical signal collection from forearm muscles. The EMG sensor array data is fused with inertial measurement unit (IMU) data. This paper describes the BioSleeve system and presents initial results of decoding robot commands from the EMG and IMU data using a BioSleeve prototype with up to sixteen bipolar surface EMG sensors. The BioSleeve is demonstrated on the recognition of static hand positions (e.g. palm facing front, fingers upwards) and on dynamic gestures (e.g. hand wave). In preliminary experiments, over 90% correct recognition was achieved on five static and nine dynamic gestures. We use the BioSleeve to control a team of five LANdroid robots in individual and group/squad behaviors. We define a gesture composition mechanism that allows the specification of complex robot behaviors with only a small vocabulary of gestures/commands, and we illustrate it with a set of complex orders.

  9. Using Arm and Hand Gestures to Command Robots during Stealth Operations

    NASA Technical Reports Server (NTRS)

    Stoica, Adrian; Assad, Chris; Wolf, Michael; You, Ki Sung; Pavone, Marco; Huntsberger, Terry; Iwashita, Yumi

    2012-01-01

    Command of support robots by the warfighter requires intuitive interfaces to quickly communicate high degree-of-freedom (DOF) information while leaving the hands unencumbered. Stealth operations rule out voice commands and vision-based gesture interpretation techniques, as they often entail silent operations at night or in other low visibility conditions. Targeted at using bio-signal inputs to set navigation and manipulation goals for the robot (say, simply by pointing), we developed a system based on an electromyography (EMG) "BioSleeve", a high density sensor array for robust, practical signal collection from forearm muscles. The EMG sensor array data is fused with inertial measurement unit (IMU) data. This paper describes the BioSleeve system and presents initial results of decoding robot commands from the EMG and IMU data using a BioSleeve prototype with up to sixteen bipolar surface EMG sensors. The BioSleeve is demonstrated on the recognition of static hand positions (e.g. palm facing front, fingers upwards) and on dynamic gestures (e.g. hand wave). In preliminary experiments, over 90% correct recognition was achieved on five static and nine dynamic gestures. We use the BioSleeve to control a team of five LANdroid robots in individual and group/squad behaviors. We define a gesture composition mechanism that allows the specification of complex robot behaviors with only a small vocabulary of gestures/commands, and we illustrate it with a set of complex orders.

  10. Insulation Testing Using Cryostat Apparatus with Sleeve

    NASA Technical Reports Server (NTRS)

    Fesmire, J. E.; Augustynowicz, S. D.

    1999-01-01

    The method and equipment of testing continuously rolled insulation materials is presented in this paper. Testing of blanket and molded products is also facilitated. Materials are installed around a cylindrical copper sleeve using a wrapping machine. The sleeve is slid onto the vertical cold mass of the cryostat. The gap between the cold mass and the sleeve measures less than 1 mm. The cryostat apparatus is a liquid nitrogen boiloff calorimeter system that enables direct measurement of the apparent thermal conductivity (k-value) of the insulation system at any vacuum level between 5 x 10(exp -5) and 760 torr. Sensors are placed between layers of the insulation to provide complete temperature-thickness profiles. The temperatures of the cold mass (maintained at 77.8 kelvin (K)), the sleeve (cold boundary temperature (CBT)), the insulation outer surface (warm boundary temperature (WBT)), and the vacuum can (maintained at 313 K by a thermal shroud) are measured. Plots of CBT, WBT, and layer temperature profiles as functions of vacuum level show the transitions between the three dominant heat transfer modes. For this cryostat apparatus, the measureable heat gain is from 0.2 to 20 watts. The steady-state measurement of k-value is made when all temperatures and the boiloff rate are stable.

  11. 77 FR 54796 - Airworthiness Directives; Eurocopter France Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-06

    ... Airworthiness Directives; Eurocopter France Helicopters AGENCY: Federal Aviation Administration (FAA), DOT... France Model AS350 helicopters. This AD requires installing protection sleeves over certain forward... helicopters have been approved by the aviation authority of France and are approved for operation in the...

  12. 75 FR 50854 - Airworthiness Directives; The Boeing Company Model 767-300 Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-18

    ... and installing a tetrafluoroethylene (TFE 2X) sleeve. This AD results from fuel system reviews... for fuel tank systems. As a result of those findings, we issued a regulation titled ``Transport Airplane Fuel Tank System Design Review, Flammability Reduction and Maintenance and Inspection Requirements...

  13. Coming out prevention by stopper for the shrink fitted sandwiched shaft from the ceramic sleeve

    NASA Astrophysics Data System (ADS)

    Zhang, Guowei; Noda, Nao-Aki; Sano, Yoshikazu; Sakai, Hiromasa; Oda, Kazuhiro

    2017-05-01

    Ceramic roller can be used in the heating furnace conveniently because of its high temperature resistance. The roller consists of sleeve and steel shaft connected only under a small shrink fitting ratio because of the brittleness. However, the coming out of the shaft may often happen from the ceramic sleeve under repeated bending load. Therefore, how to prevent the coming out failure becomes an important issue. Based on the previous study, a two-dimensional shrink fitted structure is considered by replacing the shaft with the inner plate and by replacing the sleeve with the outer plate. Then, this research focuses on preventing the inner plate coming out from the outer plate by introducing a newly designed stopper on the outer plate. The simulation results shows that the coming out phenomenon can be prevented effectively due to the contact between the inter plate and the stopper installed on the outer plate. In order to evaluate the contact force between the inner plate and the stopper, the coming out mechanism is clarified. To prevent the coming out by stopper safely, the effects of the magnitude of repeated load and the friction coefficient upon the contact compressive force are investigated under large number of loading cycles by using 2D simulation.

  14. 75 FR 36577 - Airworthiness Directives; McDonnell Douglas Corporation Model MD-90-30 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-28

    ... pump wire harness assembly is routed within the tire burst area and that installing and routing a new and longer auxiliary hydraulic pump wire harness assembly outside the tire burst area will minimize... general visual inspection of the wire harness protective sleeving dimensions, which are related...

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, W.M.; Tison, M.; Bahoumina, A.

    The tieback of eleven 10 3/4-in., high-pressure risers in Elf Congo`s offshore N`Kossa field used a cold-forge tieback system to create a metal seal. The time-saving tieback method allows for placing the risers in residual tension. The installation work was completed in the fall of 1995. Average time to complete the 10 3/4-in. casing tiebacks, including test and nipple-up and nipple-down times, averaged 52 hr/well. Tiebacks for all three casing strings averaged 90 hr for all surface and subsea operations including BOP test and nipple-up/nipple-down time. Metal sealing of the primary casing annulus has been made practical because the offshoremore » industry has gone toward compact-wellheads and hanging of the completion on a mandrel. Hanging the completion on a mandrel, however, has it own set of considerations. Exact riser length may be difficult to predict before running because the riser must first be locked into the mudline casing hanger and then landed out on the support shoulder in the surface head. Also, a general desire is that riser tieback strings should be in tension after installation. This is not always easy with a passive or dumb hanger and fixed should configuration. Threaded, adjustable mandrel hanger systems exist but can require very close casing string space-out to achieve the desired residual riser tension. The paper describes the objectives, forged sleeves, running sequence, cold forging, and the prototype test.« less

  16. A revolutionary design change to improve stapler safety.

    PubMed

    Arteaga-González, Iván J

    2013-01-01

    Postoperative staple line leaks and bleeding are the most common reasons for complications in surgical procedures that involve organ resection, such as sleeve gastrectomy. Increasing the safety of these operations requires improving the instruments (endostaplers or endocutters) used for stapling and sectioning the tissues. We present a new prototype stapler for marketing in resection surgery, especially designed for the sleeve gastrectomy. We suggest that the medical instrument industry creates devices in which the channel along which the knife blade runs is located asymmetrically. This would allow more staples to be placed on the side of the gastric remnant, thus improving the sealing and hemostasis of the suture line and reducing the number of complications for patients as a result. The application of new concepts in medical surgical devices can improve the safety of the procedures in our patients.

  17. 77 FR 54850 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-06

    ... sources in the auxiliary (center) fuel tank, main fuel tanks, and surge tanks caused by a wiring short or... on the rear spar, and installation of a TFE sleeve if necessary. This proposed AD would also add... sources in the auxiliary (center) fuel tank, main fuel tanks, and surge tanks caused by a wiring short or...

  18. Nanoose Range Current Characteristics at 274m Depth

    DTIC Science & Technology

    1977-05-01

    BUOYANT iL 41 4 , PLASTIC SLEEVES OVER NYLON ROPES SSHACKLE TO PAD EYES Si-BOMISI Figure 3. VACM Installation Atop BOMIS 14 L Report 13711 lij~ j I. 54 I...1__ H 4 *Report 1311 Appendix A TABLE 5.. INDICATED PEAK TIDAL CURRENqT CARACTERISTICS @ 30.5 meters: There is no apparent preferred ebb or flood

  19. 46 CFR 160.135-11 - Fabrication of prototype lifeboats for approval.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... The Commandant may prescribe additional prototype tests and inspections necessary to maintain quality... inspecting— (i) Fiber Reinforced Plastic (FRP) Construction. (A) FRP components of each prototype lifeboat... system; (vii) Installation of the steering system; and (viii) Installation of the water spray fire...

  20. 46 CFR 160.135-11 - Fabrication of prototype lifeboats for approval.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... The Commandant may prescribe additional prototype tests and inspections necessary to maintain quality... inspecting— (i) Fiber Reinforced Plastic (FRP) Construction. (A) FRP components of each prototype lifeboat... system; (vii) Installation of the steering system; and (viii) Installation of the water spray fire...

  1. 46 CFR 160.135-11 - Fabrication of prototype lifeboats for approval.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... The Commandant may prescribe additional prototype tests and inspections necessary to maintain quality... inspecting— (i) Fiber Reinforced Plastic (FRP) Construction. (A) FRP components of each prototype lifeboat... system; (vii) Installation of the steering system; and (viii) Installation of the water spray fire...

  2. [COMPUTER ASSISTED DESIGN AND ELECTRON BEAMMELTING RAPID PROTOTYPING METAL THREE-DIMENSIONAL PRINTING TECHNOLOGY FOR PREPARATION OF INDIVIDUALIZED FEMORAL PROSTHESIS].

    PubMed

    Liu, Hongwei; Weng, Yiping; Zhang, Yunkun; Xu, Nanwei; Tong, Jing; Wang, Caimei

    2015-09-01

    To study the feasibility of preparation of the individualized femoral prosthesis through computer assisted design and electron beammelting rapid prototyping (EBM-RP) metal three-dimensional (3D) printing technology. One adult male left femur specimen was used for scanning with 64-slice spiral CT; tomographic image data were imported into Mimics15.0 software to reconstruct femoral 3D model, then the 3D model of individualized femoral prosthesis was designed through UG8.0 software. Finally the 3D model data were imported into EBM-RP metal 3D printer to print the individualized sleeve. According to the 3D model of individualized prosthesis, customized sleeve was successfully prepared through the EBM-RP metal 3D printing technology, assembled with the standard handle component of SR modular femoral prosthesis to make the individualized femoral prosthesis. Customized femoral prosthesis accurately matching with metaphyseal cavity can be designed through the thin slice CT scanning and computer assisted design technology. Titanium alloy personalized prosthesis with complex 3D shape, pore surface, and good matching with metaphyseal cavity can be manufactured by the technology of EBM-RP metal 3D printing, and the technology has convenient, rapid, and accurate advantages.

  3. Morphing Compression Garments for Space Medicine and Extravehicular Activity Using Active Materials.

    PubMed

    Holschuh, Bradley T; Newman, Dava J

    2016-02-01

    Compression garments tend to be difficult to don/doff, due to their intentional function of squeezing the wearer. This is especially true for compression garments used for space medicine and for extravehicular activity (EVA). We present an innovative solution to this problem by integrating shape changing materials-NiTi shape memory alloy (SMA) coil actuators formed into modular, 3D-printed cartridges-into compression garments to produce garments capable of constricting on command. A parameterized, 2-spring analytic counterpressure model based on 12 garment and material inputs was developed to inform garment design. A methodology was developed for producing novel SMA cartridge systems to enable active compression garment construction. Five active compression sleeve prototypes were manufactured and tested: each sleeve was placed on a rigid cylindrical object and counterpressure was measured as a function of spatial location and time before, during, and after the application of a step voltage input. Controllable active counterpressures were measured up to 34.3 kPa, exceeding the requirement for EVA life support (29.6 kPa). Prototypes which incorporated fabrics with linear properties closely matched analytic model predictions (4.1%/-10.5% error in passive/active pressure predictions); prototypes using nonlinear fabrics did not match model predictions (errors >100%). Pressure non-uniformities were observed due to friction and the rigid SMA cartridge structure. To our knowledge this is the first demonstration of controllable compression technology incorporating active materials, a novel contribution to the field of compression garment design. This technology could lead to easy-to-don compression garments with widespread space and terrestrial applications.

  4. Integrated Structural and Cable Connector

    NASA Technical Reports Server (NTRS)

    Totah, R. S.

    1982-01-01

    Ball-and-socket coupling includes fiber-optic cable. Three steps couple two parts of fiber-optic cable: ball is inserted into socket; cone is released in, and cable moves toward plug. Sleeve is pulled to end of its travel and cable and plug are mated. Device is a quick-connect/disconnect coupling that has application in hazardous environments, such as space, undersea and nuclear installations.

  5. Evaluations of bit sleeve and twisted-body bit designs for controlling roof bolter dust

    PubMed Central

    Beck, T.W.

    2015-01-01

    Drilling into coal mine roof strata to install roof bolts has the potential to release substantial quantities of respirable dust. Due to the proximity of drill holes to the breathing zone of roof bolting personnel, dust escaping the holes and avoiding capture by the dust collection system pose a potential respiratory health risk. Controls are available to complement the typical dry vacuum collection system and minimize harmful exposures during the initial phase of drilling. This paper examines the use of a bit sleeve in combination with a dust-hog-type bit to improve dust extraction during the critical initial phase of drilling. A twisted-body drill bit is also evaluated to determine the quantity of dust liberated in comparison with the dust-hog-type bit. Based on the results of our laboratory tests, the bit sleeve may reduce dust emissions by one-half during the initial phase of drilling before the drill bit is fully enclosed by the drill hole. Because collaring is responsible for the largest dust liberations, overall dust emission can also be substantially reduced. The use of a twisted-body bit has minimal improvement on dust capture compared with the commonly used dust-hog-type bit. PMID:26257435

  6. KENNEDY SPACE CENTER, FLA. - An overview of the Space Station Processing Facility shows workstands and ISS elements. The most recent additions are the Japanese Experiment Module (JEM)’s pressurized module and the Italian-built Node 2. The pressurized module is the first element of the JEM, Japan’s primary contribution to the Space Station, to be delivered to KSC. It will enhance the unique research capabilities of the orbiting complex by providing an additional shirt-sleeve environment for astronauts to conduct science experiments. Node 2 will be installed on the end of the U.S. Lab and provides attach locations for the Japanese laboratory, European laboratory, the Centrifuge Accommodation Module and, later, Multipurpose Logistics Modules. It will provide the primary docking location for the Shuttle when a pressurized mating adapter is attached to Node 2. Installation of the module will complete the U.S. Core of the ISS.

    NASA Image and Video Library

    2003-06-06

    KENNEDY SPACE CENTER, FLA. - An overview of the Space Station Processing Facility shows workstands and ISS elements. The most recent additions are the Japanese Experiment Module (JEM)’s pressurized module and the Italian-built Node 2. The pressurized module is the first element of the JEM, Japan’s primary contribution to the Space Station, to be delivered to KSC. It will enhance the unique research capabilities of the orbiting complex by providing an additional shirt-sleeve environment for astronauts to conduct science experiments. Node 2 will be installed on the end of the U.S. Lab and provides attach locations for the Japanese laboratory, European laboratory, the Centrifuge Accommodation Module and, later, Multipurpose Logistics Modules. It will provide the primary docking location for the Shuttle when a pressurized mating adapter is attached to Node 2. Installation of the module will complete the U.S. Core of the ISS.

  7. KENNEDY SPACE CENTER, FLA. - A view of the Space Station Processing Facility shows workstands and ISS elements. The most recent additions are the Japanese Experiment Module (JEM)’s pressurized module and the Italian-built Node 2. The pressurized module is the first element of the JEM, Japan’s primary contribution to the Space Station, to be delivered to KSC. It will enhance the unique research capabilities of the orbiting complex by providing an additional shirt-sleeve environment for astronauts to conduct science experiments. Node 2 will be installed on the end of the U.S. Lab and provides attach locations for the Japanese laboratory, European laboratory, the Centrifuge Accommodation Module and, later, Multipurpose Logistics Modules. It will provide the primary docking location for the Shuttle when a pressurized mating adapter is attached to Node 2. Installation of the module will complete the U.S. Core of the ISS.

    NASA Image and Video Library

    2003-06-06

    KENNEDY SPACE CENTER, FLA. - A view of the Space Station Processing Facility shows workstands and ISS elements. The most recent additions are the Japanese Experiment Module (JEM)’s pressurized module and the Italian-built Node 2. The pressurized module is the first element of the JEM, Japan’s primary contribution to the Space Station, to be delivered to KSC. It will enhance the unique research capabilities of the orbiting complex by providing an additional shirt-sleeve environment for astronauts to conduct science experiments. Node 2 will be installed on the end of the U.S. Lab and provides attach locations for the Japanese laboratory, European laboratory, the Centrifuge Accommodation Module and, later, Multipurpose Logistics Modules. It will provide the primary docking location for the Shuttle when a pressurized mating adapter is attached to Node 2. Installation of the module will complete the U.S. Core of the ISS.

  8. 75 FR 60602 - Airworthiness Directives; McDonnell Douglas Corporation Model DC-10-10, DC-10-10F, DC-10-15, DC...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-01

    ... fuel pump pressure switches. This AD results from fuel system reviews conducted by the manufacturer. We.... Unsafe Condition (e) This AD results from fuel system reviews conducted by the manufacturer. The Federal... installing an in-line fuse in certain float level switches and sleeving the wires between the fuel tank and...

  9. Wet snow hazard for power lines: a forecast and alert system applied in Italy

    NASA Astrophysics Data System (ADS)

    Bonelli, P.; Lacavalla, M.; Marcacci, P.; Mariani, G.; Stella, G.

    2011-09-01

    Wet snow icing accretion on power lines is a real problem in Italy, causing failures on high and medium voltage power supplies during the cold season. The phenomenon is a process in which many large and local scale variables contribute in a complex way and not completely understood. A numerical weather forecast can be used to select areas where wet snow accretion has an high probability of occurring, but a specific accretion model must also be used to estimate the load of an ice sleeve and its hazard. All the information must be carefully selected and shown to the electric grid operator in order to warn him promptly. The authors describe a prototype of forecast and alert system, WOLF (Wet snow Overload aLert and Forecast), developed and applied in Italy. The prototype elaborates the output of a numerical weather prediction model, as temperature, precipitation, wind intensity and direction, to determine the areas of potential risk for the power lines. Then an accretion model computes the ice sleeves' load for different conductor diameters. The highest values are selected and displayed on a WEB-GIS application principally devoted to the electric operator, but also to more expert users. Some experimental field campaigns have been conducted to better parameterize the accretion model. Comparisons between real accidents and forecasted icing conditions are presented and discussed.

  10. Prototype road weather performance management (RWPM) tool installation instructions & user manual.

    DOT National Transportation Integrated Search

    2016-07-20

    This document is the Installation Instructions and User Manual for the Road Weather Performance Management (RW-PM) Tool developed for the project on Development and Demonstration of a Prototype Road Weather Performance Management Application that Use...

  11. Prototype road weather performance management tool : installation instructions & user manual.

    DOT National Transportation Integrated Search

    2016-07-20

    This document is the Installation Instructions and User Manual for the Road Weather Performance Management (RW-PM) Tool developed for the project on Development and Demonstration of a Prototype Road Weather Performance Management Application that Use...

  12. Gasket and snap ring installation tool

    DOEpatents

    Southerland, Jr., James M.; Barringer, Jr., Curtis N.

    1994-01-01

    A tool for installing a gasket and a snap ring including a shaft, a first plate attached to the forward end of the shaft, a second plate slidably carried by the shaft, a spring disposed about the shaft between the first and second plates, and a sleeve that is free to slide over the shaft and engage the second plate. The first plate has a loading surface with a loading groove for receiving a snap ring and a shoulder for holding a gasket. A plurality of openings are formed through the first plate, communicating with the loading groove and approximately equally spaced about the groove. A plurality of rods are attached to the second plate, each rod slidable in one of the openings. In use, the loaded tool is inserted into a hollow pipe or pipe fitting having an internal flange and an internal seating groove, such that the gasket is positioned against the flange and the ring is in the approximate plane of the seating groove. The sleeve is pushed against the second plate, sliding the second plate towards the first plate, compressing the spring and sliding the rods forwards in the openings. The rods engage the snap ring and urge the ring from the loading groove into the seating groove.

  13. Thermocouple psychrometer measurements of in situ water potential changes in heated welded tuff

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mao, Nai-hsien; Wang, H.F.

    1991-10-01

    Ten thermocouple psychrometers (TCPs) to measure water potential (WP) were installed in three holes in G-Tunnel at the Nevada Test Site as part of the Prototype Engineered Barrier System Field Tests. We calibrated the TCPs in NaCl solutions up to 80{degrees}C (176{degrees}F) in the laboratory. In two holes, we used rubber sleeves and packers to house TCPs, and in the third hole, we used foam. All three holes were grouted behind the TCP assemblages. The initial moisture condition indicated by TCP data was about 99.5% relative humidity or a WP of about {minus}5 bar. This corresponded to 15.4 g/m{sup 3}more » of water in the air near the borehole wall, which was much wetter than we expected. A drying and re-wetting cycle peaked at about day 140 with a WP of {minus}65 bar in borehole P3, located below the heater. A similar cycle but reduced in scale was found at about day 175 with a WP of {minus}45 bar in borehole P2, above the heater. This difference is drying behavior above and below the heater was also observed from neutron data and was explained as a gravity effect.« less

  14. Alternative design of pipe sleeve for liquid removal mechanism in mortar slab layer

    NASA Astrophysics Data System (ADS)

    Nazri, W. M. H. Wan; Anting, N.; Lim, A. J. M. S.; Prasetijo, J.; Shahidan, S.; Din, M. F. Md; Anuar, M. A. Mohd

    2017-11-01

    Porosity is one of the mortar’s characteristics that can cause problems, especially in the room space that used high amount of water, such as bathrooms. Waterproofing is one of the technology that normally used to minimize this problem which is preventing deep penetration of liquid water or moisture into underlying concrete layers. However, without the proper mechanism to remove liquid water and moisture from mortar system, waterproofing layer tends to be damaged after a long period of time by the static formation of liquid water and moisture at mortar layer. Thus, a solution has been proposed to drain out water that penetrated into the mortar layer. This paper introduces a new solution using a Modified Pipe Sleeve (MPS) that installed at the mortar layer. The MPS has been designed considering the percentage surface area of the pipe sleeve that having contact with mortar layer (2%, 4%, 6%, 8% and 10%) with angle of holes of 60°. Infiltration test and flow rate test have been conducted to identify the effectiveness of the MPS in order to drain out liquid water or moisture from the mortar layer. In this study shows that, MPS surface area 10%, angled 60°, function effectively as a water removal compared to other design.

  15. PROTOTYPE EICHER FISH SCREEN AND EVALUATION FACILITY, INSTALLED IN 1990 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PROTOTYPE EICHER FISH SCREEN AND EVALUATION FACILITY, INSTALLED IN 1990 ON #1 PENSTOCK. PROJECT SPONSORED BY THE ELECTRICAL POWER RESEARCH INSTITUTE TO TRANSFER FISH DOWNSTREAM PAST THE TURBINES. PHOTO BY JET LOWE, HAER, 1995. - Elwha River Hydroelectric System, Elwha Hydroelectric Dam & Plant, Port Angeles, Clallam County, WA

  16. Installation package - SIMS prototype system 1A

    NASA Technical Reports Server (NTRS)

    1976-01-01

    This report consists of details for the installation, operation and maintenance of a prototype heating and hot water system, designed for residential or light commercial applications. This system consists of the following subsystems: air type collectors, pebble bed thermal storage, air handling unit, air to water heat exchanger, hot water preheat tank, auxiliary energy, ducting system.

  17. Installation package for SIMS prototype system 2, solar hot water

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The prototype system 2 solar hot water was designed for use in a single family dwelling and consists of the following subsystems: collector, storage, energy transport, and control. Guidelines are presented for utilization in the development of detailed installation plans and specifications. Instruction on operation, maintenance, and repair of the system is discussed.

  18. SIMS prototype system 1: Design data brochure. [solar heating system

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A prototype solar heating and hot water system using air as the collector fluid and a pebble bed for heat storage was designed for installation into a single family dwelling. The system, subsystem, and installation requirements are described. System operation and performance are discussed, and procedures for sizing the system to a specific site are presented.

  19. Overview of the experimental tests in prototype

    NASA Astrophysics Data System (ADS)

    Egusquiza, Eduard; Valentín, David; Presas, Alexandre; Valero, Carme

    2017-04-01

    Experimental tests in prototype are necessary to understand the dynamic behaviour of the machine during different operating points. Hydraulic phenomena as well as its effect on the structure need to be studied in order to avoid instabilities during operation and to extend the life-time of the different components. For this purpose, a complete experimental study of a large Francis turbine prototype has been performed installing several sensors along the machine. Pressure sensors were installed in the penstock, spiral case, runner and draft tube, strain gauges were installed in the runner, vibration sensors were used in the stationary parts and different electrical and operational parameters were also measured. All these signals were acquired simultaneously for different operating points of the turbine.

  20. Nuclear reactor flow control method and apparatus

    DOEpatents

    Church, J.P.

    1993-03-30

    Method and apparatus for improving coolant flow in a nuclear reactor during accident as well as nominal conditions. The reactor has a plurality of fuel elements in sleeves and a plenum above the fuel and through which the sleeves penetrate. Holes are provided in the sleeve so that coolant from the plenum can enter the sleeve and cool the fuel. The number and size of the holes are varied from sleeve to sleeve with the number and size of holes being greater for sleeves toward the center of the core and less for sleeves toward the periphery of the core. Preferably the holes are all the same diameter and arranged in rows and columns, the rows starting from the bottom of every sleeve and fewer rows in peripheral sleeves and more rows in the central sleeves.

  1. Nuclear reactor flow control method and apparatus

    DOEpatents

    Church, John P.

    1993-01-01

    Method and apparatus for improving coolant flow in a nuclear reactor during accident as well as nominal conditions. The reactor has a plurality of fuel elements in sleeves and a plenum above the fuel and through which the sleeves penetrate. Holes are provided in the sleeve so that coolant from the plenum can enter the sleeve and cool the fuel. The number and size of the holes are varied from sleeve to sleeve with the number and size of holes being greater for sleeves toward the center of the core and less for sleeves toward the periphery of the core. Preferably the holes are all the same diameter and arranged in rows and columns, the rows starting from the bottom of every sleeve and fewer rows in peripheral sleeves and more rows in the central sleeves.

  2. Effect of Yaw Angle and Ambient Wind on Fabric Penetration of a Simulated Sleeve

    DTIC Science & Technology

    2015-08-20

    aerosol dissemination is made using an array of tubing with ejectors (usually in the tunnel contraction or settling chamber) that allow dissemination...atomizing nozzle (Spray Systems, Co., Wheaton, Illinois, 1/4JAUMCO- 316SS2050) that was installed in a 2.5-gal pressure tank (W.R. Brown Co., North Chicago...Illinois, Model Speed). An earth-grounded, 5-gal pressure tank held a mixture of 200-proof ethanol and 10% DOS. The tank was generally set to 6 psi

  3. UKIRT Upgrades Program: design and installation of the Dome Ventilation System (DVS)

    NASA Astrophysics Data System (ADS)

    Neff, D. H.; Hileman, Edward A.; Kain, S. J.; Cavedoni, Charles P.; Chuter, Timothy C.

    1997-03-01

    In order to encourage adequate dome ventilation to reduce or eliminate dome seeing at the 3.8 m United Kingdom Infrared Telescope (UKIRT), a dome ventilation system (DVS) was designed to be installed in the lower dome skirt. The modifications to the dome for the new DVS apertures consisted of installing a reinforcing frame containing an insulated rollup door and adjustable louvers. This paper describes the finite element structural analysis of the reinforcing frame, the detailed design of the frame hardware, the design of the programmable language control (PLC) system for controlling the opening and closing of the rollup doors, and the fabrication and installation of a prototype frame assembly. To date, a prototype assembly has been installed that confirms the design, and fifteen production assemblies are currently under fabrication for installation by September 1996.

  4. STS-128 EVA 3 Node 3 Tranquility Avionics Cable Routing OPS

    NASA Image and Video Library

    2009-09-05

    S128-E-007720 (5 Sept. 2009) --- NASA astronaut John “Danny” Olivas (left) and European Space Agency astronaut Christer Fuglesang, both STS-128 mission specialists, participate in the mission's third and final session of extravehicular activity (EVA) as construction and maintenance continue on the International Space Station. During the seven-hour, one-minute spacewalk, Olivas and Fuglesang deployed the Payload Attachment System (PAS), replaced the Rate Gyro Assembly #2, installed two GPS antennae and did some work to prepare for the installation of Node 3 next year. During connection of one of two sets of avionics cables for Node 3, one of the connectors could not be mated. This cable and connector were wrapped in a protective sleeve and safed. All other cables were mated successfully.

  5. A new environment for multiple spacecraft power subsystem mission operations

    NASA Technical Reports Server (NTRS)

    Bahrami, K. A.

    1990-01-01

    The engineering analysis subsystem environment (EASE) is being developed to enable fewer controllers to monitor and control power and other spacecraft engineering subsystems. The EASE prototype has been developed to support simultaneous real-time monitoring of several spacecraft engineering subsystems. It is being designed to assist with offline analysis of telemetry data to determine trends, and to help formulate uplink commands to the spacecraft. An early version of the EASE prototype has been installed in the JPL Space Flight Operations Facility for online testing. The EASE prototype is installed in the Galileo Mission Support Area. The underlying concept, development, and testing of the EASE prototype and how it will aid in the ground operations of spacecraft power subsystems are discussed.

  6. Sleeve gastrectomy with anti-reflux procedures

    PubMed Central

    Santoro, Sergio; Lacombe, Arnaldo; de Aquino, Caio Gustavo Gaspar; Malzoni, Carlos Eduardo

    2014-01-01

    Objective Sleeve gastrectomy is the fastest growing surgical procedure to treat obesity in the world but it may cause or worsen gastroesophageal reflux disease. This article originally aimed to describe the addition of anti-reflux procedures (removal of periesophageal fats pads, hiatoplasty, a small plication and fixation of the gastric remnant in position) to the usual sleeve gastrectomy and to report early and late results. Methods Eighty-eight obese patients that also presented symptoms of gastroesophageal reflux disease were submitted to sleeve gastrectomy with anti-reflux procedures. Fifty of them were also submitted to a transit bipartition. The weight loss of these patients was compared to consecutive 360 patients previously submitted to the usual sleeve gastrectomy and to 1,140 submitted to sleeve gastrectomy + transit bipartition. Gastroesophageal reflux disease symptoms were specifically inquired in all anti-reflux sleeve gastrectomy patients and compared to the results of the same questionnaire applied to 50 sleeve gastrectomy patients and 60 sleeve gastrectomy + transit bipartition patients that also presented preoperative symptoms of gastroesophageal reflux disease. Results In terms of weight loss, excess of body mass index loss percentage after anti-reflux sleeve gastrectomy is not inferior to the usual sleeve gastrectomy and anti-reflux sleeve gastrectomy + transit bipartition is not inferior to sleeve gastrectomy + transit bipartition. Anti-reflux sleeve gastrectomy did not add morbidity but significantly diminished gastroesophageal reflux disease symptoms and the use of proton pump inhibitors to treat this condition. Conclusion The addition of anti-reflux procedures, such as hiatoplasty and cardioplication, to the usual sleeve gastrectomy did not add morbidity neither worsened the weight loss but significantly reduced the occurrence of gastroesophageal reflux disease symptoms as well as the use of proton pump inhibitors. PMID:25295447

  7. Stuck fuel rod capping sleeve

    DOEpatents

    Gorscak, Donald A.; Maringo, John J.; Nilsen, Roy J.

    1988-01-01

    A stuck fuel rod capping sleeve to be used during derodding of spent fuel assemblies if a fuel rod becomes stuck in a partially withdrawn position and, thus, has to be severed. The capping sleeve has an inner sleeve made of a lower work hardening highly ductile material (e.g., Inconel 600) and an outer sleeve made of a moderately ductile material (e.g., 304 stainless steel). The inner sleeve may be made of an epoxy filler. The capping sleeve is placed on a fuel rod which is then severed by using a bolt cutter device. Upon cutting, the capping sleeve deforms in such a manner as to prevent the gross release of radioactive fuel material

  8. Prototype solar heating and combined heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Eight prototype solar heating and combined heating and cooling systems are considered. This effort includes development, manufacture, test, installation, maintenance, problem resolution, and performance evaluation.

  9. Development and evaluation of gas-pressurized elastic sleeves for extravehicular activity.

    PubMed

    Tanaka, Kunihiko; Tohnan, Momoka; Abe, Chikara; Iwata, Chihiro; Yamagata, Kenji; Tanaka, Masao; Tanaka, Nobuyuki; Morita, Hironobu

    2010-07-01

    In space, mobility of the current extravehicular activity space suit is limited due to the pressure differential between the inside and outside of the suit. We have previously demonstrated that an elastic glove increased mobility when compared with a non-elastic glove such as that found in the current suit. Extending this work, we hypothesized that an elastic sleeve would also have more mobility compared to a non-elastic sleeve, but a partially elastic sleeve, consisting of elastic joints sewn to non-elastic parts in low mobility areas, might generate similar mobility to a wholly elastic sleeve. The right arms of 10 volunteers were studied with wholly elastic, partially elastic, and non-elastic sleeves in a chamber pressure of -220 mmHg. Range of motion (ROM) of the wrist and electromyography (EMG) of the flexor carpi radialis muscle and the biceps brachii muscle during wrist and elbow flexion were measured. ROM of the wrist was similar among all the sleeves. However, EMG amplitudes during wrist flexion with both elastic sleeves were significantly smaller than that with the non-elastic sleeve. EMG amplitudes during 90 degrees of elbow flexion were also significantly smaller in both elastic sleeves. However, no significant difference in EMG amplitudes was observed between the two elastic sleeves (0.53 +/- 0.06, 0.56 +/- 0.07, 1.14 +/- 0.10 V for wholly elastic, partially elastic, and non-elastic sleeves, respectively). The mobility of elastic sleeves is better than that of a non-elastic sleeve. Elasticity over the joints is important; however the elasticity of the other parts does not appear to affect mobility.

  10. Prototype solar heating and combined heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Eight prototype solar heating and combined heating and cooling systems are being developed. The effort includes development, manufacture, test, installation, maintenance, problem resolution, and performance evaluation.

  11. Performance of Superconducting Magnet Prototypes for LCLS-II Linear Accelerator

    DOE PAGES

    Kashikhin, Vladimir; Andreev, Nikolai; DiMarco, Joseph; ...

    2017-01-05

    The new LCLS-II Linear Superconducting Accelerator at SLAC needs superconducting magnet packages installed inside SCRF Cryomodules to focus and steer an electron beam. Two magnet prototypes were built and successfully tested at Fermilab. Magnets have an iron dominated configuration, quadrupole and dipole NbTi superconducting coils, and splittable in the vertical plane configuration. Magnets inside the Cryomodule are conductively cooled through pure Al heat sinks. Both magnets performance was verified by magnetic measurements at room temperature, and during cold tests in liquid helium. Test results including magnetic measurements are discussed. Special attention was given to the magnet performance at low currentsmore » where the iron yoke and the superconductor hysteresis effects have large influence. Both magnet prototypes were accepted for the installation in FNAL and JLAB prototype Cryomodules.« less

  12. Permafrost Ecosystem Warming Prototype: Installation, Operation, and Initial Site Characterization

    DTIC Science & Technology

    2013-11-01

    report Approved for public release; distribution is unlimited. Prepared for US Army Corps of Engineers Washington , DC 20314-1000 Monitored by...in 3 m diameter plots in a temperate deciduous forest. To further develop the prototype for an arctic climate, a similar test system was installed...growth trees and shrubs. The site was chosen because of its permafrost characteristics, ease of access, and its close proximity to the CRREL Fairbanks

  13. Heat flux limiting sleeves

    DOEpatents

    Harris, William G.

    1985-01-01

    A heat limiting tubular sleeve extending over only a portion of a tube having a generally uniform outside diameter, the sleeve being open on both ends, having one end thereof larger in diameter than the other end thereof and having a wall thickness which decreases in the same direction as the diameter of the sleeve decreases so that the heat transfer through the sleeve and tube is less adjacent the large diameter end of the sleeve than adjacent the other end thereof.

  14. Summary report, Flexible VSR`s and VSR channel sleeve development programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kempf, F.J.

    1963-11-15

    (VSR = vertical safety rod.) This report summarizes results of development programs which have evaluated vertical rod channel sleeving materials and provided flexible vertical rods, acceptable for both interim use before rod channel sleeving, and for subsequent use in sleeved channels. B{sub 4}C is the rod material; graphite and Al oxide are among the sleeve materials.

  15. Improved corrosion control by coating in the splash zone and subsea

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    John, R.C.; VanHooff, W.

    1989-01-01

    The splash zone around offshore structures is without doubt one of nature's most hostile and corrosive environments. Apart from the wave impacts, plentiful supplies of oxygen, lack of cathodic protection, and the salt spray that continually wets and then dries upon objects, the region is difficult and sometimes dangerous to access. This article reviews the performance of two new offshore repair coatings recently installed on North Sea and Gulf of Mexico installations. The first coating, a reinforced heat-shrinkable sleeve, is designed to be installed over properly cleaned and dried steel surfaces. Suitable conditions for the application of this coating existmore » during low tide and calm weather when certain exposed sections of the splash zone are accessible. Alternatively, by using a special remote-controlled cofferdam chamber to create an artificial local environment, subsea coating application can proceed under ideal conditions. Cofferdam chamber installations are diver-free and can be made throughout the entire splash zone, even during rough weather. When a remote-controlled cofferdam is not available and repairs are needed in subsea or wet areas, diver assistance is usually required. The second coating system, a gel-based, diver-applied tape, has been developed specifically for such applications.« less

  16. Apparatus and method for measuring the expansion properties of a cement composition

    DOEpatents

    Spangle, Lloyd B.

    1983-01-01

    An apparatus is disclosed which is useful for measuring the expansion properties of semi-solid materials which expand to a solid phase, upon curing, such as cement compositions. The apparatus includes a sleeve, preferably cylindrical, which has a vertical slit on one side, to allow the sleeve to expand. Mounted on the outside of the sleeve are several sets of pins, consisting of two pins each. The two pins in each set are located on opposite sides of the slit. In the test procedure, the sleeve is filled with wet cement, which is then cured to a solid. As the cement cures it causes the sleeve to expand. The actual expansion of the sleeve represents an expansion factor for the cement. This factor is calculated by measuring the distance across the pins of each set, when the sleeve is empty, and again after the cured cement expands the sleeve.

  17. GCT, the Gamma-ray Cherenkov Telescope for multi-TeV science with the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Sol, H.; Dournaux, J.-L.; Laporte, P.

    2016-12-01

    GCT is a gamma-ray telescope proposed for the high-energy section of the Cherenkov Telescope Array (CTA). A GCT prototype telescope has been designed, built and installed at the Observatoire de Paris in Meudon. Equipped with the first GCT prototype camera developed by an international collaboration, the complete GCT prototype was inaugurated in December 2015, after getting its first Cherenkov light on the night sky in November. The phase of tests, assessment, and optimisation is now coming to an end. Pre-production of the first GCT telescopes and cameras should start in 2017, for an installation on the Chilean site of CTA in 2018.

  18. Pressurizer with a mechanically attached surge nozzle thermal sleeve

    DOEpatents

    Wepfer, Robert M

    2014-03-25

    A thermal sleeve is mechanically attached to the bore of a surge nozzle of a pressurizer for the primary circuit of a pressurized water reactor steam generating system. The thermal sleeve is attached with a series of keys and slots which maintain the thermal sleeve centered in the nozzle while permitting thermal growth and restricting flow between the sleeve and the interior wall of the nozzle.

  19. Installation package for a domestic solar heating and hot water system

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The installation of two prototype solar heating and hot water systems is described. The systems consists of the following subsystems: solar collector, storage, control, transport, and auxiliary energy.

  20. Finite element Analysis of Semi-Grouting Sleeve Connection Member Based on ABAQUS

    NASA Astrophysics Data System (ADS)

    Bao, Longsheng; Fan, Qianyu; Wang, Ling

    2018-05-01

    This paper use investigates the force transfer mechanism and failure form of semi-grouting sleeve members under axial load, analyze the weak points of structural bearing capacity and verify the reliability of the connection of steel bars through finite element analysis software. The results show that adding the axial load to semi-grouting sleeve forms a 45°oblique compression zone, which help to transfer stress between reinforcement, grouting material and sleeve. Because the maximum stress of sleeve doesn’t reach its tensile resistance and the deformation of the sleeve is located at the junction of the grouting and the threaded section when the stress value of steel bars at each end of the semi-grouting sleeve reach its ultimate tensile strength, we conclude that the semi-grouting sleeve members can meet the construction quality requirements and be used to connect the steel bars at the joints of the assembled structures. It is necessary to avoid breaking down, since the deformation section will accumulate large plastic deformation during the processing of the sleeve.

  1. Installation package for Hyde Memorial Observatory, Lincoln, Nebraska

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Installation information for a solar heating system installed in Hyde Memorial Observatory at Lincoln, Nebraska is presented. This package included a system operation and maintenance manual, hardware brochures, schematics, system operating modes, and drawings. This prototype solar heating system consisted of the following subsystems: solar collector, control, and storage.

  2. Installation package for the Solaron solar subsystem

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Information that is intended to be a guide for installation, operation, and maintenance of the various solar subsystems is presented. The subsystems consist of the following: collectors, storage, transport (air handler) and controller for heat pump and peak storage. Two prototype residential systems were installed at Akron, Ohio, and Duffield, Virginia.

  3. PCR thermocycler

    DOEpatents

    Benett, William J.; Richards, James B.

    2003-01-01

    A sleeve-type silicon polymerase chain reaction (PCR) chamber or thermocycler having improved thermal performance. The silicon sleeve reaction chamber is improved in thermal performance by etched features therein that reduce thermal mass and increase the surface area of the sleeve for cooling. This improved thermal performance of the thermocycler enables an increase in speed and efficiency of the reaction chamber. The improvement is accomplished by providing grooves in the faces of the sleeve and a series of grooves on the interior surfaces that connect with grooves on the faces of the sleeve. The grooves can be anisotropically etched in the silicon sleeve simultaneously with formation of the chamber.

  4. PCR thermocycler

    DOEpatents

    Benett, William J.; Richards, James B.

    2005-05-17

    A sleeve-type silicon polymerase chain reaction (PCR) chamber or thermocycler having improved thermal performance. The silicon sleeve reaction chamber is improved in thermal performance by etched features therein that reduce thermal mass and increase the surface area of the sleeve for cooling. This improved thermal performance of the thermocycler enables an increase in speed and efficiency of the reaction chamber. The improvement is accomplished by providing grooves in the faces of the sleeve and a series of grooves on the interior surfaces that connect with grooves on the faces of the sleeve. The grooves can be anisotropically etched in the silicon sleeve simultaneously with formation of the chamber.

  5. Dysphagia after vertical sleeve gastrectomy: Evaluation of risk factors and assessment of endoscopic intervention.

    PubMed

    Nath, Anand; Yewale, Sayali; Tran, Tung; Brebbia, John S; Shope, Timothy R; Koch, Timothy R

    2016-12-21

    To evaluate the risks of medical conditions, evaluate gastric sleeve narrowing, and assess hydrostatic balloon dilatation to treat dysphagia after vertical sleeve gastrectomy (VSG). VSG is being performed more frequently worldwide as a treatment for medically-complicated obesity, and dysphagia is common post-operatively. We hypothesize that post-operative dysphagia is related to underlying medical conditions or narrowing of the gastric sleeve. This is a retrospective, single institution study of consecutive patients who underwent sleeve gastrectomy from 2013 to 2015. Patients with previous bariatric procedures were excluded. Narrowing of a gastric sleeve includes: inability to pass a 9.6 mm gastroscope due to stenosis or sharp angulation or spiral hindering its passage. Of 400 consecutive patients, 352 are included; the prevalence of dysphagia is 22.7%; 33 patients (9.3%) have narrowing of the sleeve with 25 (7.1%) having sharp angulation or a spiral while 8 (2.3%) have a stenosis. All 33 patients underwent balloon dilatation of the gastric sleeve and dysphagia resolved in 13 patients (39%); 10 patients (30%) noted resolution of dysphagia after two additional dilatations. In a multivariate model, medical conditions associated with post-operative dysphagia include diabetes mellitus, symptoms of esophageal reflux, a low whole blood thiamine level, hypothyroidism, use of non-steroidal anti-inflammatory drugs, and use of opioids. Narrowing of the gastric sleeve and gastric sleeve stenosis are common after VSG. Endoscopic balloon dilatations of the gastric sleeve resolves dysphagia in 69% of patients.

  6. Dysphagia after vertical sleeve gastrectomy: Evaluation of risk factors and assessment of endoscopic intervention

    PubMed Central

    Nath, Anand; Yewale, Sayali; Tran, Tung; Brebbia, John S; Shope, Timothy R; Koch, Timothy R

    2016-01-01

    AIM To evaluate the risks of medical conditions, evaluate gastric sleeve narrowing, and assess hydrostatic balloon dilatation to treat dysphagia after vertical sleeve gastrectomy (VSG). METHODS VSG is being performed more frequently worldwide as a treatment for medically-complicated obesity, and dysphagia is common post-operatively. We hypothesize that post-operative dysphagia is related to underlying medical conditions or narrowing of the gastric sleeve. This is a retrospective, single institution study of consecutive patients who underwent sleeve gastrectomy from 2013 to 2015. Patients with previous bariatric procedures were excluded. Narrowing of a gastric sleeve includes: inability to pass a 9.6 mm gastroscope due to stenosis or sharp angulation or spiral hindering its passage. RESULTS Of 400 consecutive patients, 352 are included; the prevalence of dysphagia is 22.7%; 33 patients (9.3%) have narrowing of the sleeve with 25 (7.1%) having sharp angulation or a spiral while 8 (2.3%) have a stenosis. All 33 patients underwent balloon dilatation of the gastric sleeve and dysphagia resolved in 13 patients (39%); 10 patients (30%) noted resolution of dysphagia after two additional dilatations. In a multivariate model, medical conditions associated with post-operative dysphagia include diabetes mellitus, symptoms of esophageal reflux, a low whole blood thiamine level, hypothyroidism, use of non-steroidal anti-inflammatory drugs, and use of opioids. CONCLUSION Narrowing of the gastric sleeve and gastric sleeve stenosis are common after VSG. Endoscopic balloon dilatations of the gastric sleeve resolves dysphagia in 69% of patients. PMID:28058017

  7. FLEXIBLE COUPLING

    DOEpatents

    Babelay, E.F.

    1962-02-13

    A flexible shaft coupling for operation at speeds in excess of 14,000 rpm is designed which requires no lubrication. A driving sleeve member and a driven sleeve member are placed in concentric spaced relationship. A torque force is transmitted to the driven member from the driving member through a plurality of nylon balls symmetrically disposed between the spaced sleeves. The balls extend into races and recesses within the respective sleeve members. The sleeve members have a suitable clearance therebetween and the balls have a suitable radial clearance during operation of the coupling to provide a relatively loose coupling. These clearances accommodate for both parallel and/or angular misalignments and avoid metal-tometal contact between the sleeve members during operation. Thus, no lubrication is needed, and a minimum of vibrations is transmitted between the sleeve members. (AEC)

  8. Prototype solar heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Eight prototype systems were developed. The systems are 3, 25, and 75-ton size units. The manufacture, test, installation, maintenance, problem resolution, and performance evaluation of the systems is described. Size activities for the various systems are included.

  9. Motorized wellbore fishing tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, L.E.; Schasteen, T.

    1989-08-15

    This patent describes a fishing tool for retrieving an article located in a wellbore, wherein the fishing tool may be lowered into the wellbore by means connected to one end of the fishing tool. The fishing tool comprising: an elongated tubular body; an inner sleeve member secured to the body and extending axially within the body; a ball key disposed within each of the openings and movable at least partially into the bore in locking registration with a fishing head connected to the article; an outer sleeve member disposed in sleeved relationship around the inner sleeve member and movable axiallymore » between first and second positions with respect to the inner sleeve member. The outer sleeve member being operable to prevent, in the first position, radial outward movement of the ball keys out of the bore. The outer sleeve member including recess means formed thereon such that in the second position of the outer sleeve member the recess means is adjacent to the circumferentially spaced openings to allow limited radial outward movement of the ball keys; and means for axially moving the outer sleeve member between the first and second positions for engaging and releasing the fishing head with respect to the tool.« less

  10. Inspection and repair of steam generator tubing with a robot

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boehm, H.H.; Foerch, H.

    1985-11-01

    During inspection and repair of steam generator tubing, radiation exposure to personnel is an unrequested endowment. To combat this intrinsic handicap, a robot has been designed for deployment in all operations inside the steam generator water chamber. This measure drastically reduces entering time and also improves inspection capabilities with regard to the accuracy and reproduction of the desired tube address. The inherent flexibility of the robot allows for performing various inspection and repair techniques: eddy-current testing of tubing; ultrasonic testing of tubing; visual examination of tube ends; profilometry measurements; tube plugging; plug removal; tube extraction; sleeving of tubes; tube endmore » repair; chemical cleaning; and thermal treatment. Plant experience has highlighted the following features of the robot: 1) short installation and demounting periods; 2) installation independent of manhole location; 3) installation possible from outside the steam generator; 4) only one relocation required to address all the tube positions; 5) fast and highly accurate positioning; 6) operational surveillance not required; and 7) drastic reduction of radiation exposure to personnel during repair work.« less

  11. Effects of a Prophylactic Knee Sleeve on Anterior Cruciate Ligament Loading During Sport Specific Movements.

    PubMed

    Sinclair, Jonathan; Taylor, Paul John

    2017-07-17

    Prophylactic knee bracing is extensively utilized in athletic populations, to reduce the high risk from knee injuries, but their role in the attenuation of anterior cruciate ligament (ACL) pathologies is not well understood. The aim of the current investigation was to investigate the effects of a prophylactic knee sleeve on ACL loading parameters linked to the aetiology of injury in recreational athletes. Laboratory. Repeated measures. Thirteen healthy male recreational athletes. Intervention Participants performed run, cut and single leg hop movements under two conditions; prophylactic knee sleeve and no-sleeve. Biomechanical data was captured using an eight-camera 3D motion capture system and a force platform. Peak ACL force, average ACL load rate and instantaneous ACL load rate were quantified using a musculoskeletal modelling approach. The results showed that both average and instantaneous ACL load rates were significantly reduced when wearing the knee sleeve in the hop (sleeve = 612.45/ 1286.39N/kg/s & no-sleeve = 743.91/ 1471.42 N/kg/s) and cut (sleeve = 222.55/ 1058.02 N/kg/s & no-sleeve = 377.38/ 1183.01 N/kg/s) movements. Given the biomechanical association between ACL loading and the aetiology of ACL injuries, it is proposed that athletes may be able to attenuate their risk from injury during cut and hop movements through utilization of a prophylactic knee sleeve.

  12. Evaluation of Prototype Automatic Truck Rollover Warning Systems

    DOT National Transportation Integrated Search

    1998-01-01

    Three operating prototype Automatic Truck Rollover Warning Systems (ATRWS) installed on the Capital Beltway in Maryland and Virginia were evaluated for 3 years. The general objectives of this evaluation were to assess how the ATRWS performed and to d...

  13. Qualitative Flow Visualization of a 110-N Hydrogen/Oxygen Laboratory Model Thruster

    NASA Technical Reports Server (NTRS)

    deGroot, Wim A.; McGuire, Thomas J.; Schneider, Steven J.

    1997-01-01

    The flow field inside a 110 N gaseous hydrogen/oxygen thruster was investigated using an optically accessible, two-dimensional laboratory test model installed in a high altitude chamber. The injector for this study produced an oxidizer-rich core flow, which was designed to fully mix and react inside a fuel-film sleeve insert before emerging into the main chamber section, where a substantial fuel film cooling layer was added to protect the chamber wall. Techniques used to investigate the flow consisted of spontaneous Raman spectra measurements, visible emission imaging, ultraviolet hydroxyl spectroscopy, and high speed schlieren imaging. Experimental results indicate that the oxygen rich core flow continued to react while emerging from the fuel-film sleeve, suggesting incomplete mixing of the hydrogen in the oxygen rich core flow. Experiments also showed that the fuel film cooling protective layer retained its integrity throughout the straight section of the combustion chamber. In the converging portion of the chamber, however, a turbulent reaction zone near the wall destroyed the integrity of the film layer, a result which implies that a lower contraction angle may improve the fuel film cooling in the converging section and extend the hardware lifetime.

  14. 40-MW(E) PROTOTYPE HIGH-TEMPERATURE GAS-COOLED REACTOR RESEARCH AND DEVELOPMENT PROGRAM. Quarterly Progress Report for the Period Ending June 30, 1962

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1963-10-31

    Research and development progress specifically directed toward the construction of a 40-Mw(e) prototype power plant employing a high-temperature, gas-cooled, graphitemoderated reactor known as the HTGR is reported. Irradiation of element III-B in the in-pile loop continued satisfactorily. The element has generated a total of l36.3 Mw-hr of fission heat. The gross activity in the purge stream increased slightly to about 350 mu C/cm/sup 3/. By taking larger gas samples than were previously taken, a value of 0.02 VC/cm/sup 3/ was obtained for the gross activity of the primary loop. Element III-A, which was removed from the loop after generating 133more » Mw-hr of fission heat, was disassembled and examined. No fuel-compact damage of any type was visible. Determination of the distribution of fission products in the element is under way, Fissionproduct- release data for in-pile-loop element III-A were calculated. During the 133 Mw- hr of operation, the release fraction increased by approximately one order of magnitude. Also calculated were the xenon and krypton release data for the first 100 Mw-hr of III-B operation. The release rate for the longer-lived isotopes increased bv about a factor of 10 and that of the shorter-lived isotopes by about a factor of 100. A test was run in which the in-pileloop purge flow, was stopped. The primariy-loop activity level rose sharply during the first hour, increased at a slower rate for the next 11 hr, and then appeared to level off. When purge flow was resumed, the gross activity in the primary loop was cleaned up with a half life of about 2.2 hr. An attempt was made to identify Cs/sup 137/ and Ba/ sup 140/ plateout in portions of the in-pile loop. A very small amount of cesium (less than a monolayer) was found, but no barium could be detected. The validity of two basic assumptions made in the one-dimensional burnup code FEVER was investigated. As a result of extensive lifetime studies and power-distribution and temperaturecoefficient calculations, the initial fuel loading for the Peach Bottom core was specified. A series of control-rodworth calculations and a recalculation of the postulated rod-fall accident were made for this loading. The test of the prototype control rod and drive was satisfactorily coNonempleted during the quarter. During the course of the test the drive completed 590,641 starts and stops, 5,756 scrams, and more than 2.6 million inches of random regulating motion in helium at reactor temperatures. These totals far exceed the expected life requirements of the system. Preparations are being made for testing the prototype emergency shutdown rod and drive. The apparatus for the barium permeation experiment with a full-diameter sleeve was completed, and preliminary calibration runs were started. Following these runs, the system will be operated until an equilibrium distribution of barium is reached. At that time, a series of corings will be made on all of the compacts and the sleeve to evaluate the overall barium and strontium distribution. Other experiments on barium behavior, including permeation experiments with reducedscale fuel elements and exVeriments on the vaporization, sorption, and diffusion of barium, were continued, and the data are being analyzed. Measurements were made to compare the room-temperature back diffusion of argon, krypton, and xenon through a sample of sleeve graphite against a helium pressure difference. The results show that the difference between the effective back-diffusion coefficients of krypton and xenon seems to increase with increasing helium pressure difference across the sleeve. The argon and krypton back-diffusion data at an average pressure of 3 atm are essentially the same, A FORTRAN code was written to recalculate the retention of neutron poison material and fission products in the core as well as their condensation on and revaporization from the upper reflector following a complete loss-of-coolant-circulation accident. (auth)« less

  15. Mechanism Research on Melting Loss of Coppery Tuyere Small Sleeve in Blast Furnace

    NASA Astrophysics Data System (ADS)

    Chai, Yi-Fan; Zhang, Jian-Liang; Ning, Xiao-Jun; Wei, Guang-Yun; Chen, Yu-Ting

    2016-01-01

    The tuyere small sleeve in blast furnace works under poor conditions. The abnormal damage of it will severely affect the performance of the blast furnace, thus it should be replaced during the damping down period. So it is of great significance that we study and reduce the burnout of tuyere small sleeve. Melting loss is one case of its burnout. This paper studied the reasons of tuyere small sleeve's melting loss, through computational simulation and microscopic analysis of the melting section. The research shows that the temperature of coppery tuyere small sleeve is well distributed when there is no limescale in the lumen, and the temperature increases with the thickness of limescale. In addition, the interruption of circulating water does great harm to the tuyere small sleeve. The melting loss of tuyere small sleeve is caused by iron-slag erosion, with the occurrence of the melt metallurgical bonding and diffusion metallurgical combination.

  16. Comparison of stiffness and interface pressure during rest and exercise among various arm sleeves.

    PubMed

    Hirai, M; Niimi, K; Iwata, H; Sugimoto, I; Ishibashi, H; Ota, T; Nakamura, H

    2010-08-01

    To compare the interface pressure during rest and exercise among various kinds of arm sleeves. The interface pressure underneath nine different arm sleeves was measured during 10 maximal opening and closing movements of fingers using a pressure transducer (Air Pack Type Analyser) in 16 healthy volunteers. Furthermore, in order to evaluate the characteristics of each arm sleeve, the extensibility, stiffness and thickness were determined in vitro by several apparatuses. There was a significant correlation between stiffness and extensibility. The stiffness was significantly correlated with the pressure difference between muscle contraction and relaxation during exercise. The higher the value of stiffness, the greater the pressure amplitude during exercise. Short-stretch arm sleeves characterized with a high level stiffness, including thick round- and flat-knitted arm sleeves, are more beneficial for the augmentation of muscle pumping than long-stretch arm sleeves, in the same way as short-stretch bandages or stockings applied to the leg.

  17. Swell Sleeves for Testing Explosive Devices

    NASA Technical Reports Server (NTRS)

    Hinkel, Todd J.; Dean, Richard J.; Hohmann, Carl W.; Hacker, Scott C.; Harrington, Douglas W.; Bacak, James W.

    2003-01-01

    A method of testing explosive and pyrotechnic devices involves exploding the devices inside swell sleeves. Swell sleeves have been used previously for measuring forces. In the present method, they are used to obtain quantitative indications of the energy released in explosions of the devices under test. A swell sleeve is basically a thick-walled, hollow metal cylinder threaded at one end to accept a threaded surface on a device to be tested (see Figure 1). Once the device has been tightly threaded in place in the swell sleeve, the device-and-swell-sleeve assembly is placed in a test fixture, then the device is detonated. After the explosion, the assembly is removed from the test fixture and placed in a coordinate-measuring machine for measurement of the diameter of the swell sleeve as a function of axial position. For each axial position, the original diameter of the sleeve is subtracted from the diameter of the sleeve as swollen by the explosion to obtain the diametral swelling as a function of axial position (see Figure 2). The amount of swelling is taken as a measure of the energy released in the explosion. The amount of swelling can be compared to a standard amount of swelling to determine whether the pyrotechnic device functioned as specified.

  18. Design and characterization of a hyperelastic tubular soft composite.

    PubMed

    Shaheen, Robert; Doumit, Marc; Helal, Alexander

    2017-11-01

    Research in the field of human mobility assistive devices, aiming to reduce the metabolic cost of daily activities, is seeing the benefits of the exclusive use of passive actuators to store and release energy during the gait cycle. Current devices commonly employ either mechanical springs or Pneumatic Artificial Muscles as the primary method of passive actuation. The Pneumatic Artificial Muscle has proven to be a superior actuation choice for these devices, when compared to its alternatives. However, challenges regarding muscle pressure loss and limited elongation potential have been identified. This paper presents a hyperelastic tubular Soft Composite that replicates the distinctive mechanical behaviour of the Pneumatic Artificial Muscle without the need for internal pressurization. The proposed Soft Composite solution is achieved by impregnating a prefabricated polyethylene terephthalate braided sleeve, held at a high initial fibre angle, with a silicone prepolymer. A comprehensive experimental evaluation is achieved on numerous prototypes for a variety of customizable design parameters including: the initial fibre angle, the silicone stiffness, and the braided sleeve style. This research has successfully developed, tested, and validated a novel Soft Composite that can achieve the desired nonlinear stiffness and elongation potential for optimal use as passive actuation in human mobility assistive devices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Design data brochure: SIMS prototype system 2

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Information is provided on the design and performance of the IBM SIMS Prototype System 2, solar domestic hot water system, for single family residences. The document provides sufficient data to permit procurement, installation, operation, and maintenance by qualified architectural engineers or contractors.

  20. Advanced component testing : Kaskasia handbrake test.

    DOT National Transportation Integrated Search

    2016-07-01

    The evaluation of a prototype remote operation handbrake showed that it can be installed on a car with only minor modifications to connect the air. This prototype did not set the emergency during any of the testing performed. The operation of the pro...

  1. Fretting and Corrosion Damage in Taper Adapter Sleeves for Ceramic Heads: A Retrieval Study.

    PubMed

    MacDonald, Daniel W; Chen, Antonia F; Lee, Gwo-Chin; Klein, Gregg R; Mont, Michael A; Kurtz, Steven M; Cates, Harold E; Kraay, Matthew J; Rimnac, Clare M

    2017-09-01

    During revision surgery with a well-fixed stem, a titanium sleeve can be used in conjunction with a ceramic head to achieve better stress distribution across the taper surface. In vitro testing suggests that corrosion is not a concern in sleeved ceramic heads; however, little is known about the in vivo fretting corrosion of the sleeves. The purpose of this study was to investigate fretting corrosion in sleeved ceramic heads in retrieved total hip arthroplasties. Thirty-seven sleeved ceramic heads were collected during revision. The femoral heads and sleeves were implanted 0.0-3.3 years. The implants were revised predominantly for instability, infection, and loosening. Fifty percent of the retrievals were implanted during a primary surgery. Fretting corrosion was assessed using the Goldberg-Higgs semiquantitative scoring system. Mild-to-moderate fretting corrosion scores (score = 2-3) were observed in 92% of internal tapers, 19% of external tapers, and 78% of the stems. Severe fretting corrosion was observed in 1 stem trunnion that was previously retained during revision surgery and none of the retrieved sleeves. There was no difference in corrosion damage of sleeves used in primary or revision surgery. The fretting corrosion scores in this study were predominantly mild and lower than reported fretting scores of cobalt-chrome heads in metal-on-polyethylene bearings. Although intended for use in revisions, we found that the short-term in vivo corrosion behavior of the sleeves was similar in both primary and revision surgery applications. From an in vivo corrosion perspective, sleeves are a reasonable solution for restoring the stem taper during revision surgery. Copyright © 2017. Published by Elsevier Inc.

  2. Next Generation Loading System for Detonators and Primers

    DTIC Science & Technology

    Designed , fabricated and installed next generation tooling to provide additional manufacturing capabilities for new detonators and other small...prototype munitions on automated, semi-automated and manual machines. Lead design effort, procured and installed a primary explosive Drying Oven for a pilot...facility. Designed , fabricated and installed a Primary Explosives Waste Treatment System in a pilot environmental processing facility. Designed

  3. Solar heating and cooling system design and development

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The design and development of marketable solar heating and cooling systems for single family and commercial applications is described. The delivery, installation, and monitoring of the prototype systems are discussed. Seven operational test sites are discussed in terms of system performance. Problems encountered with equipment and installation were usually due to lack of skills required for solar system installation.

  4. 35t Prototype Detector for Experiment at Long Base Line Neutrino Facility (ELBNF) Far Detector

    NASA Astrophysics Data System (ADS)

    Santucci, Gabriel; Elbnf Collaboration

    2015-04-01

    The 35ton prototype detector is a Liquid Argon Time Projection Chamber (LAr TPC) utilizing a membrane cryostat. It serves as a prototype for testing technology proposed for the ELBNF far detector. The construction of the prototype is an essential part of the ELBNF project due to the large amount of new technologies introduced for the far detector. In early 2014, it was shown that the membrane cryostat technology was able to reach and maintain the required LAr purity and an electron lifetime of 2.5 ms was achieved. The goals for the next phase include the installation of a fully functional TPC using the novel designs for the ELBNF far detector as much as possible. This includes the installation of the cold electronics, scintillation photon detectors and multiple Anode Plane Arrays with wrapped wires. In this talk I will review the status of the 35t prototype detector and describe what has been accomplished during 2014 and early 2015, including the commissioning phase and the early stages of data taking from cosmic-rays.

  5. SIMS prototype system 4 - performance test report

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A self-contained, preassembled air type solar system, designed for installation remote from the dwelling, to provide space heating and hot water was evaluated. Data analysis is included which documents the system performance and verifies its suitability for field installation.

  6. A Wideband Corner-Reflector Antenna for 240 to 400 MHz.

    DTIC Science & Technology

    1983-09-19

    8217 .; ,:,:. .-.:.,.;.. - -... - .- . -.. .-- v...- ..... .-. .-.- 1,.:..- FIGURES 1. Corner Reflector with Open-Sleeve Dipole Feed ............ ...... 7 2...Open-Sleeve Dipole Feed for Corner Reflector, 240-400 MHz........ 8 3. Closeup Photo of Open-Sleeve Dpole ..................... ...... 8 4. VSWR of...4-ft Corner Reflector, Open-Sleeve Dipole Feed .......... 9 5. Gain of Corner Reflector............ .............. . ....... 9 6. Measured E- and H

  7. System and method for manufacture of airfoil components

    DOEpatents

    Moors, Thomas Michael

    2016-11-29

    Embodiments of the present disclosure relate generally to systems and methods for manufacturing an airfoil component. The system can include: a geometrical mold; an elongated flexible sleeve having a closed-off interior and positioned within the geometrical mold, wherein the elongated flexible sleeve is further positioned to have a desired geometry; an infusing channel in fluid communication with the closed-off interior of the elongated flexible sleeve and configured to communicate a resinous material thereto; a vacuum channel in fluid communication with the closed-off interior of the elongated flexible sleeve and configured to vacuum seal the closed-off interior of the elongated flexible sleeve; and a glass fiber layer positioned within the closed-off interior of the elongated flexible sleeve.

  8. Prototype solar heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A collection of monthly status reports on the development of eight prototype solar heating and cooling systems is presented. The effort calls for the development, manufacture, test, system installation, maintenance, problem resolution, and performance evaluation. The systems are 3, 25, and 75 ton size units.

  9. Prototype solar heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A collection of monthly status reports are given on the development of eight prototype solar heating and cooling systems. This effort calls for the development, manufacturing, test, system installation, maintenance, problem resolution, and performance evaluation. The systems are 3-, 25-, and 75-ton size units.

  10. SIMS prototype system 3 test results: Engineering analysis

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The results obtained during testing of a closed hydronic drain down solar system designed for space and hot water heating is presented. Data analysis is included which documents the system performance and verifies the suitability of SIMS Prototype System 3 for field installation.

  11. SIMS prototype system 4: Design data brochure

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A pre-package prototype unit having domestic hot water and room solar heating capability that uses air as the collector fluid is described. This system is designed to be used with a small single-family dwelling where a roof mounted collector array is not feasible. The prototype unit is an assemble containing 203 square feet of effective collector surface with 113 cubic feet of rock storage. The design of structure and storage is modular, which permits expansion and reduction of the collector array and storage bed in 68 square feet and 37 cubic feet increments respectively. The system is designed to be transportable. This permitted assemble and certification testing in one area and installation in another area without tear down and reassemble. Design, installation, operation, performance and maintenance of this system are described.

  12. Mount control system of the ASTRI SST-2M prototype for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Antolini, Elisa; Tosti, Gino; Tanci, Claudio; Bagaglia, Marco; Canestrari, Rodolfo; Cascone, Enrico; Gambini, Giorgio; Nucciarelli, Giuliano; Pareschi, Giovanni; Scuderi, Salvo; Stringhetti, Luca; Busatta, Andrea; Giacomel, Stefano; Marchiori, Gianpietro; Manfrin, Cristiana; Marcuzzi, Enrico; Di Michele, Daniele; Grigolon, Carlo; Guarise, Paolo

    2016-08-01

    The ASTRI SST-2M telescope is an end-to-end prototype proposed for the Small Size class of Telescopes (SST) of the future Cherenkov Telescope Array (CTA). The prototype is installed in Italy at the INAF observing station located at Serra La Nave on Mount Etna (Sicily) and it was inaugurated in September 2014. This paper presents the software and hardware architecture and development of the system dedicated to the control of the mount, health, safety and monitoring systems of the ASTRI SST-2M telescope prototype. The mount control system installed on the ASTRI SST-2M telescope prototype makes use of standard and widely deployed industrial hardware and software. State of the art of the control and automation industries was selected in order to fulfill the mount related functional and safety requirements with assembly compactness, high reliability, and reduced maintenance. The software package was implemented with the Beckhoff TwinCAT version 3 environment for the software Programmable Logical Controller (PLC), while the control electronics have been chosen in order to maximize the homogeneity and the real time performance of the system. The integration with the high level controller (Telescope Control System) has been carried out by choosing the open platform communications Unified Architecture (UA) protocol, supporting rich data model while offering compatibility with the PLC platform. In this contribution we show how the ASTRI approach for the design and implementation of the mount control system has made the ASTRI SST-2M prototype a standalone intelligent machine, able to fulfill requirements and easy to be integrated in an array configuration such as the future ASTRI mini-array proposed to be installed at the southern site of the Cherenkov Telescope Array (CTA).

  13. Scale-up of nature's tissue weaving algorithms to engineer advanced functional materials.

    PubMed

    Ng, Joanna L; Knothe, Lillian E; Whan, Renee M; Knothe, Ulf; Tate, Melissa L Knothe

    2017-01-11

    We are literally the stuff from which our tissue fabrics and their fibers are woven and spun. The arrangement of collagen, elastin and other structural proteins in space and time embodies our tissues and organs with amazing resilience and multifunctional smart properties. For example, the periosteum, a soft tissue sleeve that envelops all nonarticular bony surfaces of the body, comprises an inherently "smart" material that gives hard bones added strength under high impact loads. Yet a paucity of scalable bottom-up approaches stymies the harnessing of smart tissues' biological, mechanical and organizational detail to create advanced functional materials. Here, a novel approach is established to scale up the multidimensional fiber patterns of natural soft tissue weaves for rapid prototyping of advanced functional materials. First second harmonic generation and two-photon excitation microscopy is used to map the microscopic three-dimensional (3D) alignment, composition and distribution of the collagen and elastin fibers of periosteum, the soft tissue sheath bounding all nonarticular bone surfaces in our bodies. Then, using engineering rendering software to scale up this natural tissue fabric, as well as multidimensional weaving algorithms, macroscopic tissue prototypes are created using a computer-controlled jacquard loom. The capacity to prototype scaled up architectures of natural fabrics provides a new avenue to create advanced functional materials.

  14. Scale-up of nature’s tissue weaving algorithms to engineer advanced functional materials

    NASA Astrophysics Data System (ADS)

    Ng, Joanna L.; Knothe, Lillian E.; Whan, Renee M.; Knothe, Ulf; Tate, Melissa L. Knothe

    2017-01-01

    We are literally the stuff from which our tissue fabrics and their fibers are woven and spun. The arrangement of collagen, elastin and other structural proteins in space and time embodies our tissues and organs with amazing resilience and multifunctional smart properties. For example, the periosteum, a soft tissue sleeve that envelops all nonarticular bony surfaces of the body, comprises an inherently “smart” material that gives hard bones added strength under high impact loads. Yet a paucity of scalable bottom-up approaches stymies the harnessing of smart tissues’ biological, mechanical and organizational detail to create advanced functional materials. Here, a novel approach is established to scale up the multidimensional fiber patterns of natural soft tissue weaves for rapid prototyping of advanced functional materials. First second harmonic generation and two-photon excitation microscopy is used to map the microscopic three-dimensional (3D) alignment, composition and distribution of the collagen and elastin fibers of periosteum, the soft tissue sheath bounding all nonarticular bone surfaces in our bodies. Then, using engineering rendering software to scale up this natural tissue fabric, as well as multidimensional weaving algorithms, macroscopic tissue prototypes are created using a computer-controlled jacquard loom. The capacity to prototype scaled up architectures of natural fabrics provides a new avenue to create advanced functional materials.

  15. Vadose zone studies at an industrial contaminated site: the vadose zone monitoring system and cross-hole geophysics

    NASA Astrophysics Data System (ADS)

    Fernandez de Vera, Natalia; Beaujean, Jean; Jamin, Pierre; Nguyen, Frédéric; Dahan, Ofer; Vanclooster, Marnik; Brouyère, Serge

    2014-05-01

    In order to improve risk characterization and remediation measures for soil and groundwater contamination, there is a need to improve in situ vadose zone characterization. However, most available technologies have been developed in the context of agricultural soils. Such methodologies are not applicable at industrial sites, where soils and contamination differ in origin and composition. In addition, most technologies are applicable only in the first meters of soils, leaving deeper vadose zones with lack of information, in particular on field scale heterogeneity. In order to overcome such difficulties, a vadose zone experiment has been setup at a former industrial site in Belgium. Industrial activities carried out on site left a legacy of soil and groundwater contamination in BTEX, PAH, cyanide and heavy metals. The experiment comprises the combination of two techniques: the Vadose Zone Monitoring System (VMS) and cross-hole geophysics. The VMS allows continuous measurements of water content and temperature at different depths of the vadose zone. In addition, it provides the possibility of pore water sampling at different depths. The system is formed by a flexible sleeve containing monitoring units along its depth which is installed in a slanted borehole. The flexible sleeve contains three types of monitoring units in the vadose zone: Time Domain Transmissometry (TDT), which allows water content measurements; Vadose Sampling Ports (VSP), used for collecting water samples coming from the matrix; the Fracture Samplers (FS), which are used for retrieving water samples from the fractures. Cross-hole geophysics techniques consist in the injection of an electrical current using electrodes installed in vertical boreholes. From measured potential differences, detailed spatial patterns about electrical properties of the subsurface can be inferred. Such spatial patterns are related with subsurface heterogeneities, water content and solute concentrations. Two VMS were installed in two slanted boreholes on site, together with four vertical boreholes containing electrodes for geophysical measurements. Currently the site is being monitored under natural recharge conditions. Initial results show the reaction of the vadose zone to rainfall events, as well as chemical evolution of soil water with depth.

  16. Electricity Submetering on the Cheap: Stick-on Electricity Meters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lanzisera, Steven; Lorek, Michael; Pister, Kristofer

    2014-08-17

    We demonstrate a low-cost, 21 x 12 mm prototype Stick-on Electricity Meter (SEM) to replace traditional in-circuit-breaker-panel current and voltage sensors for building submetering. A SEM sensor is installed on the external face of a circuit breaker to generate voltage and current signals. This allows for the computation of real and apparent power as well as capturing harmonics created by non-linear loads. The prototype sensor is built using commercially available components, resulting in a production cost of under $10 per SEM. With no highvoltage install work requiring an electrician, home owners or other individuals can install the system in amore » few minutes with no safety implications. This leads to an installed system cost that is much lower than traditional submetering technology.. Measurement results from lab characterization as well as a real-world residential dwelling installation are presented, verifying the operation of our proposed SEM sensor. The SEM sensor can resolve breaker power levels below 10W, and it can be used to provide data for non-intrusive load monitoring systems at full sample rate.« less

  17. Remotely Adjustable Hydraulic Pump

    NASA Technical Reports Server (NTRS)

    Kouns, H. H.; Gardner, L. D.

    1987-01-01

    Outlet pressure adjusted to match varying loads. Electrohydraulic servo has positioned sleeve in leftmost position, adjusting outlet pressure to maximum value. Sleeve in equilibrium position, with control land covering control port. For lowest pressure setting, sleeve shifted toward right by increased pressure on sleeve shoulder from servovalve. Pump used in aircraft and robots, where hydraulic actuators repeatedly turned on and off, changing pump load frequently and over wide range.

  18. Coring device with a improved core sleeve and anti-gripping collar with a collective core catcher

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Story, A.L.; Filshtinsky, M.

    1986-01-28

    This patent describes an improved coring apparatus used in combination with a coring bit and drill string. This device consists of: an outer driving structure adapted to be connected at one end to the coring bit for cutting a core in a borehole, and at the other end to the lower end of the drill string in telescoping and co-rotatable manner therewith; an inner barrel disposed within the outer driving structure and including a lower end portion adjacent to the bit; first means supporting the inner barrel in spaced relationship to the outer driving structure while permitting rotation of themore » driving structure with respect to the inner barrel; a woven metal mesh sleeve mounted in surrounding relation on at least a portion of the exterior surface of the inner barrel; second means, connected to a free end of the sleeve opposite the leading portion of the sleeve, for maintaining the portion of the sleeve which surrounds the inner barrel in compression and to maintain an inside diameter greater than the outside diameter of the inner barrel of the portion of the sleeve surrounding the inner barrel while the portion of the sleeve positioned inside the inner barrel being in tension to grip and compress a core received within the sleeve and having an outside diameter less than the inside diameter of the inner barrel when in tension, wherein the second means is also for engaging the core when the means is drawn into the inner barrel, and third means positioned within the inner barrel and connected to the leading portion of the sleeve to draw the sleeve within the inner barrel and to apply tension to the portion of the sleeve within the barrel to encase and grip the core as it is cut.« less

  19. Bronchovascular versus bronchial sleeve resection for central lung tumors.

    PubMed

    Lausberg, Henning F; Graeter, Thomas P; Tscholl, Dietmar; Wendler, Olaf; Schäfers, Hans-Joachim

    2005-04-01

    Pneumonectomy has traditionally been the treatment of choice for central lung tumors. Bronchial sleeve resections are increasingly considered as a reasonable alternative. For tumor involvement of both central airways and pulmonary artery, bronchovascular sleeve resections are possible, but considered to be technically demanding and associated with a higher perioperative risk. In addition, their role as adequate oncologic treatment for lung cancer is unclear. We have compared the early and long-term results of bronchovascular sleeve resection with those of bronchial sleeve resection and pneumonectomy. We retrospectively analyzed all patients who underwent bronchial sleeve resection (group I, n = 104), bronchovascular sleeve resection (group II, n = 67), and pneumonectomy (group III, n = 63) for central lung cancer in our institution. The groups were comparable regarding demographics and tumor, node, and metastasis (TNM) stage. Early mortality was 1.9% in group I, 1.5% in group II, and 6.3% in group III (p = 0.19). The rate of bronchial complications was 0.96% in group I, 0% in group II, and 7.9% in group III (p = 0.006). Five-year survival was 46.1% in group I, 42.9% in group II, and 30.4% in group III (p = 0.16). Freedom from local recurrence of disease (5 years) was 83.8% in group I, 84.2% in group II, and 88.7% in group III (p = 0.56). Bronchovascular sleeve resections are as safe as bronchial sleeve resections for the treatment of central lung cancer. Both procedures have comparable early and long-term results, which are similar to those of pneumonectomy. It appears reasonable to apply bronchovascular sleeve resections more liberally.

  20. Prototype stop bar system evaluation at John F. Kennedy International Airport.

    DOT National Transportation Integrated Search

    1992-01-01

    A prototype stop bar system was installed and evaluated at John F. Kennedy International Airport. The purpose of the year-long evaluation was to gain operational experience on the use of a stop bar system and how it could possibly impact the air traf...

  1. Combination drilling and skiving tool

    DOEpatents

    Stone, William J.

    1989-01-01

    A combination drilling and skiving tool including a longitudinally extending hollow skiving sleeve slidably and concentrically mounted on a right-handed twist drill. Dogs or pawls provided on the internal periphery of the skiving sleeve engage with the helical grooves of the drill. During a clockwise rotation of the tool, the drill moves downwardly and the sleeve translates upwardly, so that the drill performs a drilling operation on a workpiece. On the other hand, the drill moves upwardly and the sleeve translates downwardly, when the tool is rotated in a counter-clockwise direction, and the sleeve performs a skiving operation. The drilling and skiving operations are separate, independent and exclusive of each other.

  2. High-torque open-end wrench

    NASA Technical Reports Server (NTRS)

    Giandomenico, A.; Dame, J. M.; Behimer, H. (Inventor)

    1978-01-01

    A wrench is described that is usable where limited access normally requires an open-end wrench, but which has substantially the high-torque capacity and small radial clearance characteristics of a closed-end wrench. The wrench includes a sleeve forming a nut-engageable socket with a gap in its side, and an adaptor forming a socket with a gap in its side, the adaptor closely surrounding the sleeve and extending across the gap in the sleeve. The sleeve and adaptor have surfaces that become fully engaged when a wrench handle is applied to the adaptor to turn it so as to tighten a nut engaged by the sleeve.

  3. Contamination control program plan for the ultraviolet spectrometer experiment, revision E

    NASA Technical Reports Server (NTRS)

    Gilmore, D. B.

    1972-01-01

    The contamination control program plan delineates the cleanliness requirements to be attained and maintained, and the methods to be utilized, in the fabrication, handling, test, calibration, shipment, pre-installation checkout and installation for the ultraviolet spectrometer experiment prototype, qualification and flight equipment.

  4. WASTE INFORMATION MODELING (WIM) FOR CONSTRUCTION OF THE BUILT ENVIRONMENT

    EPA Science Inventory

    The outcomes will include the construction of full-scale building prototypes. As full-scale pieces are constructed they will be installed throughout the community, and could potentially be used as installations within the local community to demonstrate the use of recycled prod...

  5. Insert sleeve prevents tube soldering contamination

    NASA Technical Reports Server (NTRS)

    Stein, J.

    1966-01-01

    Teflon sleeve insert prevents contamination of internal tube surfaces by solder compound during soldering operations that connect and seal the tube ends. The sleeve insert is pressed into the mating tube ends with a slight interference fit.

  6. External combustor for gas turbine engine

    DOEpatents

    Santanam, Chandran B.; Thomas, William H.; DeJulio, Emil R.

    1991-01-01

    An external combustor for a gas turbine engine has a cyclonic combustion chamber into which combustible gas with entrained solids is introduced through an inlet port in a primary spiral swirl. A metal draft sleeve for conducting a hot gas discharge stream from the cyclonic combustion chamber is mounted on a circular end wall of the latter adjacent the combustible gas inlet. The draft sleeve is mounted concentrically in a cylindrical passage and cooperates with the passage in defining an annulus around the draft sleeve which is open to the cyclonic combustion chamber and which is connected to a source of secondary air. Secondary air issues from the annulus into the cyclonic combustion chamber at a velocity of three to five times the velocity of the combustible gas at the inlet port. The secondary air defines a hollow cylindrical extension of the draft sleeve and persists in the cyclonic combustion chamber a distance of about three to five times the diameter of the draft sleeve. The hollow cylindrical extension shields the drive sleeve from the inlet port to prevent discharge of combustible gas through the draft sleeve.

  7. ELECTROMAGNETIC APPARATUS FOR MOVING A ROD

    DOEpatents

    Young, J.N.

    1957-08-20

    An electromagnetic device for moving an object in a linear path by increments is described. The device is specifically adapted for moving a neutron absorbing control rod into and out of the core of a reactor and consists essentially of an extension member made of magnetic material connected to one end of the control rod and mechanically flexible to grip the walls of a sleeve member when flexed, a magnetic sleeve member coaxial with and slidable between limit stops along the flexible extension, electromagnetic coils substantially centrally located with respect to the flexible extension to flex the extension member into gripping engagement with the sleeve member when ener gized, moving electromagnets at each end of the sleeve to attract the sleeve when energized, and a second gripping electromagnet positioned along the flexible extension at a distance from the previously mentioned electromagnets for gripping the extension member when energized. In use, the second gripping electromagnet is deenergized, the first gripping electromagnet is energized to fix the extension member in the sleeve, and one of the moving electromagnets is energized to attract the sleeve member toward it, thereby moving the control rod.

  8. Modeling and testing of a knitted-sleeve fluidic artificial muscle

    NASA Astrophysics Data System (ADS)

    Ball, Erick J.; Meller, Michael A.; Chipka, Jordan B.; Garcia, Ephrahim

    2016-11-01

    The knitted-sleeve fluidic muscle is similar in design to a traditional McKibben muscle, with a separate bladder and sleeve. However, in place of a braided sleeve, it uses a tubular-knit sleeve made from a thin strand of flexible but inextensible yarn. When the bladder is pressurized, the sleeve expands by letting the loops of fiber slide past each other, changing the dimensions of the rectangular cells in the stitch pattern. Ideally, the internal volume of the sleeve would reach a maximum when its length has contracted by 2/3 from its maximum length, and although this is not reachable in practice, preliminary tests show that free contraction greater than 50% is achievable. The motion relies on using a fiber with a low coefficient of friction in order to reduce hysteresis to an acceptable level. In addition to increased stroke length, potential advantages of this technique include slower force drop-off during the stroke, more useable energy in certain applications, and greater similarity to the force-length relationship of skeletal muscle. Its main limitation is its potentially greater effect from friction compared to other fluidic muscle designs.

  9. 75 FR 11184 - Agency Forms Undergoing Paperwork Reduction Act Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-10

    ... ROPS. To overcome these barriers, NIOSH designed a prototype of a cost-effective roll over protective... installation complexity is significantly reduced. NIOSH has CROPS prototype designs for five tractors: Ford 3000 series, Ford 4000 series, Ford 8N, Ford 4600 and Massey-Ferguson 135. However, this technology has...

  10. Performance of the ERTS-1 DCS in a prototype volcano surveillance system

    NASA Technical Reports Server (NTRS)

    Ward, P. L.

    1975-01-01

    A prototype volcano surveillance system has been installed on 15 volcanoes in four states and four countries. The need for this system, the techniques used, the method of implementation, the major problems, the results, and the future seen for such a system are briefly reviewed.

  11. VARIABLE-THROW CAM

    DOEpatents

    Godsil, E.C.; Robinson, E.Y.

    1963-07-16

    A variable-throw cam comprising inner and outer eccentric sleeves which are adjustably locked together is described. The cam throw is varied by unlocking the inner and outer sleeves, rotating the outer sleeve relative to the inner one until the desired throw is obtained, and locking the sleeves together again. The cam is useful in applications wherein a continuously-variable throw is required, e.g., ram-and-die pressing operations, cyclic fatigue testing of materials, etc. (AEC)

  12. Safety System for Controlling Fluid Flow into a Suction Line

    NASA Technical Reports Server (NTRS)

    England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Cronise, Raymond J. (Inventor)

    2018-01-01

    A safety system includes a sleeve fitted within a pool's suction line at its inlet. The sleeve terminates with a plate that resides within the suction line. The plate has holes formed therethrough. A housing defining distinct channels is fitted in the sleeve so that the distinct channels lie within the sleeve. Each of the distinct channels has a first opening on one end thereof and a second opening on another end thereof. The second openings reside in the sleeve. The first openings are in fluid communication with the water in the pool, and are distributed around a periphery of an area of the housing that prevents coverage of all the first openings when a human interacts therewith. A first sensor is coupled to the sleeve to sense pressure therein, and a second pressure sensor is coupled to the plate to sense pressure in one of the plates' holes.

  13. Regeneratively cooled transition duct with transversely buffered impingement nozzles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrison, Jay A; Lee, Ching-Pang; Crawford, Michael E

    2015-04-21

    A cooling arrangement (56) having: a duct (30) configured to receive hot gases (16) from a combustor; and a flow sleeve (50) surrounding the duct and defining a cooling plenum (52) there between, wherein the flow sleeve is configured to form impingement cooling jets (70) emanating from dimples (82) in the flow sleeve effective to predominately cool the duct in an impingement cooling zone (60), and wherein the flow sleeve defines a convection cooling zone (64) effective to cool the duct solely via a cross-flow (76), the cross-flow comprising cooling fluid (72) exhausting from the impingement cooling zone. In themore » impingement cooling zone an undimpled portion (84) of the flow sleeve tapers away from the duct as the undimpled portion nears the convection cooling zone. The flow sleeve is configured to effect a greater velocity of the cross-flow in the convection cooling zone than in the impingement cooling zone.« less

  14. Stemless ball valve

    NASA Technical Reports Server (NTRS)

    Burgess, Kevin (Inventor); Yakos, David (Inventor); Walthall, Bryan (Inventor)

    2011-01-01

    A stemless ball valve comprising two flanges and a ball with a channel, two axis pins and two travel pins. One end of each axis and travel pin is fixedly attached to the ball, and the other end of each axis pin is lodged into a notch in the first or second flange such that the axis pin is allowed to rotate in the notch. The guide sleeve comprises two channels, and one end of each travel pin is situated within one of the two channels in the guide sleeve. An outer magnetic cartridge causes the inner magnetic cartridge and guide sleeve to rotate, and when the guide sleeve rotates, the travel pins move up and down within the channels in the guide sleeve. The movement of the travel pins within the channels in the guide sleeve causes the ball to rotate, thereby opening and closing the ball valve.

  15. Safety System for Controlling Fluid Flow into a Suction Line

    NASA Technical Reports Server (NTRS)

    England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Cronise, Raymond J. (Inventor)

    2015-01-01

    A safety system includes a sleeve fitted within a pool's suction line at the inlet thereof. An open end of the sleeve is approximately aligned with the suction line's inlet. The sleeve terminates with a plate that resides within the suction line. The plate has holes formed therethrough. A housing defining a plurality of distinct channels is fitted in the sleeve so that the distinct channels lie within the sleeve. Each of the distinct channels has a first opening on one end thereof and a second opening on another end thereof. The second openings reside in the sleeve. Each of the distinct channels is at least approximately three feet in length. The first openings are in fluid communication with the water in the pool, and are distributed around a periphery of an area of the housing that prevents coverage of all the first openings when a human interacts therewith.

  16. Wearing long sleeves while prepping a patient in the operating room decreases airborne contaminants.

    PubMed

    Markel, Troy A; Gormley, Thomas; Greeley, Damon; Ostojic, John; Wagner, Jennifer

    2018-04-01

    The use of long sleeves by nonscrubbed personnel in the operating room has been called into question. We hypothesized that wearing long sleeves and gloves, compared with having bare arms without gloves, while applying the skin preparation solution would decrease particulate and microbial contamination. A mock patient skin prep was performed in 3 different operating rooms. A long-sleeved gown and gloves, or bare arms, were used to perform the procedure. Particle counters were used to assess airborne particulate contamination, and active and passive microbial assessment was achieved through air samplers and settle plate analysis. Data were compared with Student's t-test or Mann-Whitney U, and P < .05 was considered to be significant. Operating room B demonstrated decreased 5.0- µm particle sizes with the use of sleeves, while operating rooms A and C showed decreased total microbes only with the use of sleeves. Despite there being no difference in the average number of total microbes for all operating rooms assessed, the use of sleeves specifically appeared to decrease the shed of Micrococcus. The use of long sleeves and gloves while applying the skin preparation solution decreased particulate and microbial shedding in several of the operating rooms tested. Although long sleeves may not be necessary for all operating room personnel, they may decrease airborne contamination while the skin prep is applied, which may lead to decreased surgical site infections. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  17. Apparatus for a compact adjustable passive compliant mechanism

    DOEpatents

    Salisbury, Curt Michael

    2015-03-17

    Various technologies described herein pertain to an adjustable compliance apparatus. The adjustable compliance apparatus includes a shaft, a sleeve element, and a torsion spring. The sleeve element includes a bore there through, where the shaft is positioned through the bore of the sleeve element. Further, the torsion spring includes a plurality of coils, where the shaft is positioned through the plurality of coils. Moreover, the sleeve element is slidable in an axial direction along the shaft between the torsion spring and the shaft. Accordingly, compliance of the adjustable compliance apparatus is adjustable based on a number of the plurality of coils in contact with the sleeve element as positioned along the shaft within the torsion spring.

  18. [Effect of Radii barrier sleeves on cure depth of composite resin].

    PubMed

    Wang, Binping; DU, Yongxiu

    2009-01-01

    To explore the effect of Radii barrier sleeves on the cure depth of composite resin. Cylinder mold was prepared, and the resin was filled strictly into the mold. The surface was flattened and then cured with plastic engraver's knife.The depth of composite resin which was cured by QHL75TM with or without Radii barrier sleeves was compared. The cure depth of composite resin which were cured by QHL75TM with or without Radii barrier sleeves of photo-curing machine was 4.38 mm and 4.27 mm respectively,with no statistical difference. The cure depth of composite resin is not influenced by Radii barrier sleeves under the same light condition.

  19. Rare sleeve fracture of the superior patella pole in an adult due to forceful passive physiotherapy following cast immobilization.

    PubMed

    Ro, Kyung-Han; Park, Jong-Hoon; Kim, Myo-Jong; Lee, Dae-Hee

    2014-03-01

    Sleeve fractures are generally restricted to children or adolescents, and usually occur at the lower patella pole. Here we report on a superior pole sleeve fracture in an adult that occurred following forceful passive physiotherapy after cast immobilization. To our knowledge, this is the first report of a superior pole sleeve fracture in an otherwise healthy adult. The case highlighted that a diagnosis of a superior patella pole sleeve fracture in an adult can easily be missed because it is a rare injury, and hence is unlikely to be suspected by physicians. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Left lower lobe sleeve lobectomy for lung cancer using the Da Vinci surgical system.

    PubMed

    Zhao, Yandong; Jiao, Wenjie; Ren, Xiaoyang; Zhang, Liangdong; Qiu, Tong; Fu, Bo; Wang, Lei

    2016-04-12

    Despite the robotic surgery is widely applied, sleeve lobectomy for lung cancer using the Da Vinci surgical system is still less performed. We described a sleeve lobectomy for adenocarcinoma located at the left lower lobe using the Da Vinci surgical system. A case of 57-year old female referred to our hospital. Computed tomography scan showed an occupation located at the left lower lobe and adenocarcinoma project from the lobe bronchus was diagnosed by bronchoscope examination. A sleeve lobectomy was performed using the Da Vinci surgical system and the postoperative recovery was uneventful. Robotic thoracic surgery is feasible to perform sleeve lobectomy inspite of inadequate experience.

  1. Fluid force transducer

    DOEpatents

    Jendrzejczyk, Joseph A.

    1982-01-01

    An electrical fluid force transducer for measuring the magnitude and direction of fluid forces caused by lateral fluid flow, includes a movable sleeve which is deflectable in response to the movement of fluid, and a rod fixed to the sleeve to translate forces applied to the sleeve to strain gauges attached to the rod, the strain gauges being connected in a bridge circuit arrangement enabling generation of a signal output indicative of the magnitude and direction of the force applied to the sleeve.

  2. Numerical Analysis on Tensile Properties of Grout-filled Splice Sleeve Rebars under ISO 834 Standard Fire

    NASA Astrophysics Data System (ADS)

    Liu, Yong Jun; Li, Chao; Zhou, When Jun

    2018-06-01

    This paper presents some numerical simulation results of tensile properties of reinforcing bars spliced by grout-filled coupling sleeves under fire conditions to identify the effect of load ratio on fire resistance time of spliced reinforcing bars, which provide a useful base for predicting structural behaviors of pre-cast reinforced concrete buildings in fires. A spliced rebar system investigated in this paper consists of two equal-diameter steel reinforcing bars with 25mm diameter and a straight coupling sleeve with 50mm outer and 45mm inner diameters. As a result, the thickness of grout between steel bars and sleeves are 20mm. Firstly, the temperature distributions in steel bars connected by grout- filled coupling sleeves exposed to ISO 834 standard fire were calculated utilizing finite element analysis software ANSYS. Secondly, the stress changes in heated steel bars connected by grout-filled coupling sleeves under different constant tensile loads were calculated step by step until the rebar system failed due to fire. Thus, the fire resistant time of rebar spliced by grout-filled coupling sleeves under different axial tensile loads can be determined, further, the relationship between fire resistance time and axial tensile loads ratio can could be obtained. Finally, the fire resistant times versus axial tensile load ratios curve of grout-filled splice sleeve rebars exposed to ISO 834 standard fire is presented.

  3. Preoperative endoscopy may reduce the need for revisional surgery for gastro-oesophageal reflux disease following laparoscopic sleeve gastrectomy.

    PubMed

    Madhok, B M; Carr, W R J; McCormack, C; Boyle, M; Jennings, N; Schroeder, N; Balupuri, S; Small, P K

    2016-08-01

    Laparoscopic sleeve gastrectomy is a safe and effective bariatric operation, but postoperative reflux symptoms can sometimes necessitate revisional surgery. Roux-en-Y gastric bypass is the preferred operation in morbidly obese patients with gastro-oesophageal reflux disease. In 2011, we introduced preoperative endoscopy to assess for hiatus hernia or evidence of oesophagitis in conjunction with an assessment of gastro-oesophageal reflux symptoms for all patients undergoing bariatric surgery with a view to avoid sleeve gastrectomy for these patients. A prospectively maintained database was used to identify patients who underwent sleeve gastrectomy before and after we changed the unit policy. The need for revisional surgery in patients with troublesome gastro-oesophageal reflux disease was examined. Prior to 2011, 130 patients underwent sleeve gastrectomy, and 11 (8.5%) of them required conversion to Roux-en-Y gastric bypass for symptomatic reflux disease. Following the policy change, 284 patients underwent sleeve gastrectomy, and to date, only five (1.8%) have required revisional surgery (p = 0.001). Baseline demographics were comparable between the groups, and average follow-up period was 47 and 33 months, respectively, for each group. Preoperative endoscopy and a detailed clinical history regarding gastro-oesophageal reflux symptoms may improve patient selection for sleeve gastrectomy. Avoiding sleeve gastrectomy in patients with reflux disease and/or hiatus hernia may reduce the incidence of revisional surgery. © 2016 World Obesity.

  4. Effect of Laparoscopic Sleeve Gastrectomy vs Laparoscopic Roux-en-Y Gastric Bypass on Weight Loss in Patients With Morbid Obesity: The SM-BOSS Randomized Clinical Trial.

    PubMed

    Peterli, Ralph; Wölnerhanssen, Bettina Karin; Peters, Thomas; Vetter, Diana; Kröll, Dino; Borbély, Yves; Schultes, Bernd; Beglinger, Christoph; Drewe, Jürgen; Schiesser, Marc; Nett, Philipp; Bueter, Marco

    2018-01-16

    Sleeve gastrectomy is increasingly used in the treatment of morbid obesity, but its long-term outcome vs the standard Roux-en-Y gastric bypass procedure is unknown. To determine whether there are differences between sleeve gastrectomy and Roux-en-Y gastric bypass in terms of weight loss, changes in comorbidities, increase in quality of life, and adverse events. The Swiss Multicenter Bypass or Sleeve Study (SM-BOSS), a 2-group randomized trial, was conducted from January 2007 until November 2011 (last follow-up in March 2017). Of 3971 morbidly obese patients evaluated for bariatric surgery at 4 Swiss bariatric centers, 217 patients were enrolled and randomly assigned to sleeve gastrectomy or Roux-en-Y gastric bypass with a 5-year follow-up period. Patients were randomly assigned to undergo laparoscopic sleeve gastrectomy (n = 107) or laparoscopic Roux-en-Y gastric bypass (n = 110). The primary end point was weight loss, expressed as percentage excess body mass index (BMI) loss. Exploratory end points were changes in comorbidities and adverse events. Among the 217 patients (mean age, 45.5 years; 72% women; mean BMI, 43.9) 205 (94.5%) completed the trial. Excess BMI loss was not significantly different at 5 years: for sleeve gastrectomy, 61.1%, vs Roux-en-Y gastric bypass, 68.3% (absolute difference, -7.18%; 95% CI, -14.30% to -0.06%; P = .22 after adjustment for multiple comparisons). Gastric reflux remission was observed more frequently after Roux-en-Y gastric bypass (60.4%) than after sleeve gastrectomy (25.0%). Gastric reflux worsened (more symptoms or increase in therapy) more often after sleeve gastrectomy (31.8%) than after Roux-en-Y gastric bypass (6.3%). The number of patients with reoperations or interventions was 16/101 (15.8%) after sleeve gastrectomy and 23/104 (22.1%) after Roux-en-Y gastric bypass. Among patients with morbid obesity, there was no significant difference in excess BMI loss between laparoscopic sleeve gastrectomy and laparoscopic Roux-en-Y gastric bypass at 5 years of follow-up after surgery. clinicaltrials.gov Identifier: NCT00356213.

  5. Improved design and durability of aluminum die casting horizontal shot sleeves

    NASA Astrophysics Data System (ADS)

    Birceanu, Sebastian

    The design and performance of shot sleeves is critical in meeting the engineering requirements of aluminum die cast parts. Improvement in shot sleeve materials have a major impact on dimensional stability, reproducibility and quality of the product. This investigation was undertaken in order to improve the life of aluminum die casting horizontal shot sleeves. Preliminary pin tests were run to evaluate the soldering, wash-out and thermal fatigue behavior of commercially available materials and coatings. An experimental rig was designed and constructed for shot sleeve configuration evaluation. Fabrication and testing of experimental shot sleeves was based upon preliminary results and manufacturing costs. Three shot sleeve designs and materials were compared to a reference nitrided H13 sleeve. Nitrided H13 is the preferred material for aluminum die casting shot sleeves because of wear resistance, strength and relative good soldering and wash-out resistance. The study was directed towards damage evaluation on the area under the pouring hole. This area is the most susceptible to damage because of high temperatures and impingement of molten aluminum. The results of this study showed that tungsten and molybdenum had the least amount of soldering and wash-out damage, and the best thermal fatigue resistance. Low solubility in molten aluminum and stability of intermetallic layers are main factors that determine the soldering and wash-out behavior. Thermal conductivity and thermal expansion coefficient directly influence thermal fatigue behavior. TiAlN nanolayered coating was chosen as the material with the best damage resistance among several commercial PVD coatings, because of relatively large thickness and simple deposition conditions. The results show that molybdenum thermal sprayed coating provided the best protection against damage under the pouring hole. Improved bonding is however required for life extension of the coating. TiAlN PVD coating applied on H13 nitrided substrate performed very well as long as the coating was maintained. Nitrided H13 sleeve showed extensive damage that occurred as early as 200 cycles. The nitrided layer only slowed down the diffusion process and dissolution took place at a higher rate as soon as the layer wore off. Stellite 6 sleeve also showed considerable wear under the action of molten aluminum.

  6. Design and installation of a Prototype Geohazard Monitoring System near Machu Picchu, Peru

    NASA Astrophysics Data System (ADS)

    Bulmer, M. H.; Farquhar, T.

    2010-09-01

    The town of Machu Picchu, Peru, serves the >700 000 tourists visiting Machu Picchu annually. It has grown threefold in population in the past two decades. Due to the limited low-lying ground, construction is occurring on the unstable valley slopes. Slopes range from <10° on the valley floor to >70° in the surrounding mountains. The town has grown on a delta formed at the confluence of the Alcamayo, Aguas Calientes and Vilcanota Rivers. Geohazards in and around the town of particular concern are 1) large rocks falling onto the town and/or the rail line, 2) flash flooding by any one of its three rivers, and 3) mudflows and landslides. A prototype early warning system that could monitor weather, river flow and slope stability was installed along the Aguas Calientes River in 2009. This has a distributed modular construction allowing components to be installed, maintained, salvaged, and repaired by local technicians. A diverse set of candidate power, communication and sensor technologies was evaluated. Most of the technologies had never been deployed in similar terrain, altitude or weather. The successful deployment of the prototype proved that it is technically feasible to develop early warning capacity in the town.

  7. Development and Testing of a Post-Installable Deepwater Monitoring System Using Fiber-Optic Sensors

    NASA Technical Reports Server (NTRS)

    Seaman, Calvin H.; Brower, David V.; Le, Suy Q.; Tang, Henry H.

    2015-01-01

    This paper addresses the design and development of a fiber-optic monitoring system that can be deployed on existing deepwater risers and flowlines; and provides a summary of test article fabrication and the subsequent laboratory testing performed at the National Aeronautics and Space Administration-Johnson Space Center (NASA-JSC). A major challenge of a post-installed instrumentation system is to ensure adequate coupling between the instruments and the riser or flowline of interest. This work investigates the sensor coupling for pipelines that are suspended in a water column (from topside platform to seabed) using a fiber-optic sensor clamp and subsea bonding adhesive. The study involved the design, fabrication, and test of several prototype clamps that contained fiber-optic sensors. A mold was produced by NASA using 3-D printing methods that allowed the casting of polyurethane clamp test articles to accommodate 4-inch and 8-inch diameter pipes. The prototype clamps were installed with a subsea adhesive in a "wet" environment and then tested in the NASA Structures Test Laboratory (STL). The tension, compression, and bending test data showed that the prototype sensor clamps achieved good structural coupling, and could provide high quality strain measurement for active monitoring.

  8. Biomechanical and functional efficacy of knee sleeves: A literature review.

    PubMed

    Mohd Sharif, Nahdatul Aishah; Goh, Siew-Li; Usman, Juliana; Wan Safwani, Wan Kamarul Zaman

    2017-11-01

    Knee sleeves are widely used for the symptomatic relief and subjective improvements of knee problems. To date, however, their biomechanical effects have not been well understood. To determine whether knee sleeves can significantly improve the biomechanical variables for knee problems. Systematic literature search was conducted on four online databases - PubMed, Web of Science, ScienceDirect and Springer Link - to find peer-reviewed and relevant scientific papers on knee sleeves published from January 2005 to January 2015. Study quality was assessed using the Structured Effectiveness Quality Evaluation Scale (SEQES). Twenty studies on knee sleeves usage identified from the search were included in the review because of their heterogeneous scope of coverage. Twelve studies found significant improvement in gait parameters (3) and functional parameters (9), while eight studies did not find any significant effects of knee sleeves usage. Most improvements were observed in: proprioception for healthy knees, gait and balance for osteoarthritic knees, and functional improvement of injured knees. This review suggests that knee sleeves can effect functional improvements to knee problems. However, further work is needed to confirm this hypothesis, due to the lack of homogeneity and rigor of existing studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Compressible sleeve provides automatic centering for grinding or turning of cylinders

    NASA Technical Reports Server (NTRS)

    Rohrer, J. A.

    1968-01-01

    Elastomeric sleeve supported on a threaded mandrel automatically centers cylindrical castings for grinding or turning. By expanding the diameter of the sleeve with pressure against the ends, the casting becomes rigidly supported and the surfacing operation can be completed.

  10. Power control for heat engines

    DOEpatents

    Dineen, John J.

    1984-01-01

    A power control arrangement for a Stirling engine includes a sleeve mounted in each cylinder for axial movement and a port in the sleeve leading to a dead space. The port is covered by the piston at a position that is determined by the piston position and the axial adjustment of the sleeve. The compression phase of the Stirling cycle for that piston begins when the port is covered, so the position of the sleeve is used to set the Stirling engine power level.

  11. Solar heating and cooling system design and development

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The development of eight prototype solar heating and combined heating and cooling systems is reported. Manufacture, test, installation, maintenance, problem resolution, and monitoring the operation of prototype systems is included. Heating and cooling equipment for single family residential and commercial applications and eight operational test sites (four heating and four heating and cooling) is described.

  12. Prototype solar heated hot water systems and double-walled heat exchangers: A collection of quarterly reports

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The plan schedule and status of multiple objectives to be achieved in the development, manufacture, installation, and maintenance of two solar heated hot water prototype systems and two heat exchangers are reported. A computer program developed to resolve problems and evaluate system performance is described.

  13. Hybrid neuro-fuzzy approach for automatic vehicle license plate recognition

    NASA Astrophysics Data System (ADS)

    Lee, Hsi-Chieh; Jong, Chung-Shi

    1998-03-01

    Most currently available vehicle identification systems use techniques such as R.F., microwave, or infrared to help identifying the vehicle. Transponders are usually installed in the vehicle in order to transmit the corresponding information to the sensory system. It is considered expensive to install a transponder in each vehicle and the malfunction of the transponder will result in the failure of the vehicle identification system. In this study, novel hybrid approach is proposed for automatic vehicle license plate recognition. A system prototype is built which can be used independently or cooperating with current vehicle identification system in identifying a vehicle. The prototype consists of four major modules including the module for license plate region identification, the module for character extraction from the license plate, the module for character recognition, and the module for the SimNet neuro-fuzzy system. To test the performance of the proposed system, three hundred and eighty vehicle image samples are taken by a digital camera. The license plate recognition success rate of the prototype is approximately 91% while the character recognition success rate of the prototype is approximately 97%.

  14. Strategic laparoscopic surgery for improved cosmesis in general and bariatric surgery: analysis of initial 127 cases.

    PubMed

    Nguyen, Ninh T; Smith, Brian R; Reavis, Kevin M; Nguyen, Xuan-Mai T; Nguyen, Brian; Stamos, Michael J

    2012-05-01

    Strategic laparoscopic surgery for improved cosmesis (SLIC) is a less invasive surgical approach than conventional laparoscopic surgery. The aim of this study was to examine the feasibility and safety of SLIC for general and bariatric surgical operations. Additionally, we compared the outcomes of laparoscopic sleeve gastrectomy with those performed by the SLIC technique. In an academic medical center, from April 2008 to December 2010, 127 patients underwent SLIC procedures: 38 SLIC cholecystectomy, 56 SLIC gastric banding, 26 SLIC sleeve gastrectomy, 1 SLIC gastrojejunostomy, and 6 SLIC appendectomy. SLIC sleeve gastrectomy was initially performed through a single 4.0-cm supraumbilical incision with extraction of the gastric specimen through the same incision. The technique evolved to laparoscopic incisions that were all placed within the umbilicus and suprapubic region. There were no 30-day or in-hospital mortalities or 30-day re-admissions or re-operations. For SLIC cholecystectomy, gastric banding, appendectomy, and gastrojejunostomy, conversion to conventional laparoscopy occurred in 5.3%, 5.4%, 0%, and 0%, respectively; there were no major or minor postoperative complications. For SLIC sleeve gastrectomy, there were no significant differences in mean operative time and length of hospital stay compared with laparoscopic sleeve gastrectomy; 1 (3.8%) of 26 SLIC patients required conversion to five-port laparoscopy. There were no major complications. Minor complications occurred in 7.7% in the SLIC sleeve group versus 8.3% in the laparoscopic sleeve group. SLIC in general and bariatric operations is technically feasible, safe, and associated with a low rate of conversion to conventional laparoscopy. Compared with laparoscopic sleeve gastrectomy, SLIC sleeve gastrectomy can be performed without a prolonged operative time with comparable perioperative outcomes.

  15. Sleeve gastrectomy and anti-reflux procedures.

    PubMed

    Crawford, Christopher; Gibbens, Kyle; Lomelin, Daniel; Krause, Crystal; Simorov, Anton; Oleynikov, Dmitry

    2017-03-01

    Obesity is an epidemic in the USA that continues to grow, becoming a leading cause of premature avoidable death. Bariatric surgery has become an effective solution for obesity and its comorbidities, and one of the most commonly utilized procedures, the sleeve gastrectomy, can lead to an increase in gastroesophageal reflux following the operation. While these data are controversial, sometimes operative intervention can be necessary to provide durable relief for this problem. We performed an extensive literature review examining the different methods of anti-reflux procedures that are available both before and after a sleeve gastrectomy. We reviewed several different types of anti-reflux procedures, including those that supplement the lower esophageal sphincter anatomy, such as magnetic sphincter augmentation and radiofrequency ablation procedures. Re-operation was also discussed as a possible treatment of reflux in sleeve gastrectomy, especially if the original sleeve becomes dilated or if a conversion to a Roux-en-Y gastric bypass or biliopancreatic diversion is deemed necessary. Sleeve gastrectomy with concomitant anti-reflux procedure was also reviewed, including the anti-reflux gastroplasty, hiatal hernia repair, and limited fundoplication. A number of techniques can be used to mitigate the severity of reflux, either by maintaining the normal anatomic structures that limit reflux or by supplementing these structures with a plication or gastroplasty. Individuals with existing severe reflux should not be considered for a sleeve gastrectomy. New techniques that incorporate plication at the time of the index sleeve gastrectomy show some improvement, but these are in small series that will need to be further evaluated. The only proven method of treating intractable reflux after sleeve gastrectomy is conversion to a Roux-en-Y gastric bypass.

  16. High temperature control rod assembly

    DOEpatents

    Vollman, Russell E.

    1991-01-01

    A high temperature nuclear control rod assembly comprises a plurality of substantially cylindrical segments flexibly joined together in succession by ball joints. The segments are made of a high temperature graphite or carbon-carbon composite. The segment includes a hollow cylindrical sleeve which has an opening for receiving neutron-absorbing material in the form of pellets or compacted rings. The sleeve has a threaded sleeve bore and outer threaded surface. A cylindrical support post has a threaded shaft at one end which is threadably engaged with the sleeve bore to rigidly couple the support post to the sleeve. The other end of the post is formed with a ball portion. A hollow cylindrical collar has an inner threaded surface engageable with the outer threaded surface of the sleeve to rigidly couple the collar to the sleeve. the collar also has a socket portion which cooperates with the ball portion to flexibly connect segments together to form a ball and socket-type joint. In another embodiment, the segment comprises a support member which has a threaded shaft portion and a ball surface portion. The threaded shaft portion is engageable with an inner threaded surface of a ring for rigidly coupling the support member to the ring. The ring in turn has an outer surface at one end which is threadably engageably with a hollow cylindrical sleeve. The other end of the sleeve is formed with a socket portion for engagement with a ball portion of the support member. In yet another embodiment, a secondary rod is slidably inserted in a hollow channel through the center of the segment to provide additional strength. A method for controlling a nuclear reactor utilizing the control rod assembly is also included.

  17. Device for use in loading tension members. [characterized by elongated elastic body

    NASA Technical Reports Server (NTRS)

    Appleberry, W. T. (Inventor)

    1975-01-01

    The indicator is characterized by an elongated elastic body having extended from the opposite ends of threaded shanks adapted to selected tension members. A pair of external shoulders, one of which is axially displaceable relative to the other, and a rigid tubular sleeve interposed between said shoulders are included. Tension is applied to the elastic body for imparting strain. The movable shoulder can be advanced into abutting engagement with the sleeve, whereby the sleeve is placed in compression once the tensile forces are removed from the shanks. A reapplication of tensile forces equal to the initially applied tensile forces removes the sleeve from compression, whereby the sleeve is freed for rotation for thus indicating the magnitude of the applied tensile forces.

  18. Process for the manufacture of seamless metal-clad fiber-reinforced organic matrix composite structures

    NASA Technical Reports Server (NTRS)

    Bluck, Raymond M. (Inventor); Bush, Harold G. (Inventor); Johnson, Robert R. (Inventor)

    1991-01-01

    A process for producing seamless metal-clad composite structures includes providing a hollow, metallic inner member and an outer sleeve to surround the inner member and define an inner space therebetween. A plurality of continuous reinforcing fibers is attached to the distal end of the outside diameter of the inner member, and the inner member is then introduced, distal end first, into one end of the outer sleeve. The inner member is then moved, distal end first, into the outer sleeve until the inner member is completely enveloped by the outer sleeve. A liquid matrix material is then injected into the space containing the reinforcing fibers between the inner member and the outer sleeve. Next a pressurized heat transfer medium is passed through the inner member to cure the liquid matrix material. Finally, the wall thickness of both the inner member and the outer sleeve are reduced to desired dimensions by chemical etching, which adjusts the thermal expansion coefficient of the metal-clad composite structure to a desired value.

  19. A simple technique for transferring excised patches of membrane to different solutions for single channel measurements.

    PubMed

    Quartararo, N; Barry, P H

    1987-12-01

    A technical problem associated with the patch clamp technique has been the changing of solutions bathing the membrane patch. The simple technique described here solves this problem by means of a movable polythene sleeve placed on the shaft of the patch clamp pipette. The sleeve is initially placed so that the tip of the pipette is exposed. A gigaohm seal is formed using standard techniques. The patch is then excised and the sleeve is slipped down a few mm past the end of the tip of the pipette. When the pipette and sleeve is now removed from the solution, a small drop of solution covering the membrane patch is held in place at the end of the sleeve by surface tension. The pipette is then easily transferred to a different solution without passing the membrane patch through the air-water interface. The sleeve is then simply pulled back up the pipette shaft to expose the membrane patch to the new solution.

  20. Fluid flow monitoring device

    DOEpatents

    McKay, M.D.; Sweeney, C.E.; Spangler, B.S. Jr.

    1993-11-30

    A flow meter and temperature measuring device are described comprising a tube with a body centered therein for restricting flow and a sleeve at the upper end of the tube to carry several channels formed longitudinally in the sleeve to the appropriate axial location where they penetrate the tube to allow pressure measurements and temperature measurements with thermocouples. The high pressure measurement is made using a channel penetrating the tube away from the body and the low pressure measurement is made at a location at the widest part of the body. An end plug seals the end of the device and holes at its upper end allow fluid to pass from the interior of the tube into a plenum. The channels are made by cutting grooves in the sleeve, the grooves widened at the surface of the sleeve and then a strip of sleeve material is welded to the grooves closing the channels. Preferably the sleeve is packed with powdered graphite before cutting the grooves and welding the strips. 7 figures.

  1. High precision high flow range control valve

    DOEpatents

    McCray, J.A.

    1999-07-13

    A fluid control valve is described having a valve housing having first and second valve housing openings for the ingress and egress of fluid through the control valve. Disposed within a void formed by the control valve is a sleeve having at least one sleeve opening to permit the flow of fluid therethrough. A flow restricter travels within the sleeve to progressively block off the sleeve opening and thereby control flow. A fluid passageway is formed between the first valve housing opening and the outer surface of the sleeve. A second fluid passageway is formed between the inside of the sleeve and the second valve housing opening. Neither fluid passageway contains more than one 90 [degree] turn. In the preferred embodiment only one of the two fluid passageways contains a 90[degree] turn. In another embodiment, the control valve housing is bifurcated by a control surface having control surface opening disposed therethrough. A flow restricter is in slidable contact with the control surface to restrict flow of fluid through the control surface openings. 12 figs.

  2. High precision high flow range control valve

    DOEpatents

    McCray, John A.

    1999-01-01

    A fluid control valve is described having a valve housing having first and second valve housing openings for the ingress and egress of fluid through the control valve. Disposed within a void formed by the control valve is a sleeve having at least one sleeve opening to permit the flow of fluid therethrough. A flow restricter travels within the sleeve to progressively block off the sleeve opening and thereby control flow. A fluid passageway is formed between the first valve housing opening and the outer surface of the sleeve. A second fluid passageway is formed between the inside of the sleeve and the second valve housing opening. Neither fluid passageway contains more than one 90.degree. turn. In the preferred embodiment only one of the two fluid passageways contains a 90.degree. turn. In another embodiment, the control valve housing is bifurcated by a control surface having control surface opening disposed therethrough. A flow restricter is in slidable contact with the control surface to restrict flow of fluid through the control surface openings.

  3. Model of radiation transmittance by inorganic fouling on UV reactor lamp sleeves.

    PubMed

    Wait, Isaac W; Blatchley, Ernest R

    2010-11-01

    The efficacy of UV disinfection of water depends on the ability of radiation to pass from UV lamps through the quartz sleeves that encase them; the accumulation of metal-containing foulants on sleeve surfaces inhibits disinfection by absorbing radiation that would otherwise be available for inactivation. In a series of experiments, the composition and quantity of sleeve foulants were studied relative to water chemistry and sleeve transmittance. Findings indicate that iron and calcium dominate fouling, with elevated fouling activity by iron, aluminum, manganese, and zinc. A regression-based modeling approach was used to characterize and quantify the effects of foulant metals on UV absorbance. The molar extinction coefficient for iron was found to be more than 3 times greater than that of calcium. Iron's relatively high activity in fouling reactions, elevated capacity to absorb UV, and reduced solubility under oxidizing conditions makes it a fouling precursor of particular concern, with respect to potential for sleeve fouling in UV reactors.

  4. 76 FR 59116 - Procurement List; Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-23

    ... NSN: AF110--Shirt, Class A/Primary Duty, USAF, Men's, Long Sleeve, Dark Navy Blue, Numerous Sizes. NSN: AF111--Shirt, Class A/Primary Duty, USAF, Women's, Long Sleeve, Dark Navy Blue, Numerous Sizes. NSN: AF120--Shirt, Class A/Primary Duty, USAF, Men's, Short Sleeve, Dark Navy Blue, Numerous Sizes. NSN...

  5. Use of color-coded sleeve shutters accelerates oscillograph channel selection

    NASA Technical Reports Server (NTRS)

    Bouchlas, T.; Bowden, F. W.

    1967-01-01

    Sleeve-type shutters mechanically adjust individual galvanometer light beams onto or away from selected channels on oscillograph papers. In complex test setups, the sleeve-type shutters are color coded to separately identify each oscillograph channel. This technique could be used on any equipment using tubular galvanometer light sources.

  6. Dynamic, High-Temperature, Flexible Seal

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Sirocky, Paul J.

    1989-01-01

    New seal consists of multiple plies of braided ceramic sleeves filled with small ceramic balls. Innermost braided sleeve supported by high-temperature-wire-mesh sleeve that provides both springback and preload capabilities. Ceramic balls reduce effect of relatively high porosity of braided ceramic sleeves by acting as labyrinth flow path for gases and thereby greatly increasing pressure gradient seal can sustain. Dynamic, high-temperature, flexible seal employed in hypersonic engines, two-dimensional convergent/divergent and vectorized-thrust exhaust nozzles, reentry vehicle airframes, rocket-motor casings, high-temperature furnaces, and any application requiring non-asbestos high-temperature gaskets.

  7. Inductively coupled plasma torch with laminar flow cooling

    DOEpatents

    Rayson, Gary D.; Shen, Yang

    1991-04-30

    An improved inductively coupled gas plasma torch. The torch includes inner and outer quartz sleeves and tubular insert snugly fitted between the sleeves. The insert includes outwardly opening longitudinal channels. Gas flowing through the channels of the insert emerges in a laminar flow along the inside surface of the outer sleeve, in the zone of plasma heating. The laminar flow cools the outer sleeve and enables the torch to operate at lower electrical power and gas consumption levels additionally, the laminar flow reduces noise levels in spectroscopic measurements of the gaseous plasma.

  8. 'Stent in a stent'--an alternative technique for removing partially covered stents following sleeve gastrectomy complications.

    PubMed

    Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew

    2014-03-01

    Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.

  9. Single-Axis Accelerometer

    NASA Technical Reports Server (NTRS)

    Tucker, Dennis Stephen (Inventor); Capo-Lugo, Pedro A. (Inventor)

    2016-01-01

    A single-axis accelerometer includes a housing defining a sleeve. An object/mass is disposed in the sleeve for sliding movement therein in a direction aligned with the sleeve's longitudinal axis. A first piezoelectric strip, attached to a first side of the object and to the housing, is longitudinally aligned with the sleeve's longitudinal axis. The first piezoelectric strip includes a first strip of a piezoelectric material with carbon nanotubes substantially aligned along a length thereof. A second piezoelectric strip, attached to a second side of the object and to the housing, is longitudinally aligned with the sleeve's longitudinal axis. The second piezoelectric strip includes a second strip of the piezoelectric material with carbon nanotubes substantially aligned along a length thereof. A voltage sensor is electrically coupled to at least one of the first and second piezoelectric strips.

  10. Sleeve gastrectomy and gastro-oesophageal reflux disease: a complex relationship.

    PubMed

    Mahawar, Kamal K; Jennings, Neil; Balupuri, Shlok; Small, Peter K

    2013-07-01

    Sleeve gastrectomy is rapidly becoming popular as a standalone bariatric operation. At the same time, there are valid concerns regarding its long-term durability and postoperative gastro-oesophageal reflux disease. Though gastric bypass remains the gold standard bariatric operation, it is not suitable for all patients. Sleeve gastrectomy is sometimes the only viable option. Patients with inflammatory bowel disease, liver cirrhosis, significant intra-abdominal adhesions involving small bowel and those reluctant to undergo gastric bypass could fall in this category. It is widely recognised that some patients report worsening of their gastro-oesophageal reflux disease after sleeve gastrectomy. Still, others develop de novo reflux. This review examines if it is possible to identify these patients prior to surgery and thus prevent postoperative gastro-oesophageal reflux disease after sleeve gastrectomy.

  11. Downhole steam generator with improved preheating/cooling features

    DOEpatents

    Donaldson, A. Burl; Hoke, Donald E.; Mulac, Anthony J.

    1983-01-01

    An apparatus for downhole steam generation employing dual-stage preheaters for liquid fuel and for the water. A first heat exchange jacket for the fuel surrounds the fuel/oxidant mixing section of the combustor assembly downstream of the fuel nozzle and contacts the top of the combustor unit of the combustor assembly, thereby receiving heat directly from the combustion of the fuel/oxidant. A second stage heat exchange jacket surrounds an upper portion of the oxidant supply line adjacent the fuel nozzle receiving further heat from the compression heat which results from pressurization of the oxidant. The combustor unit includes an inner combustor sleeve whose inner wall defines the combustion zone. The inner combustor sleeve is surrounded by two concentric water channels, one defined by the space between the inner combustor sleeve and an intermediate sleeve, and the second defined by the space between the intermediate sleeve and an outer cylindrical housing. The channels are connected by an annular passage adjacent the top of the combustor assembly and the countercurrent nature of the water flow provides efficient cooling of the inner combustor sleeve. An annular water ejector with a plurality of nozzles is provided to direct water downwardly into the combustor unit at the boundary of the combustion zone and along the lower section of the intermediate sleeve.

  12. Downhole steam generator with improved preheating/cooling features. [Patent application

    DOEpatents

    Donaldson, A.B.; Hoke, D.E.; Mulac, A.J.

    1980-10-10

    An apparatus is described for downhole steam generation employing dual-stage preheaters for liquid fuel and for the water. A first heat exchange jacket for the fuel surrounds the fuel/oxidant mixing section of the combustor assembly downstream of the fuel nozzle and contacts the top of the combustor unit of the combustor assembly, thereby receiving heat directly from the combustion of the fuel/oxidant. A second stage heat exchange jacket surrounds an upper portion of the oxidant supply line adjacent the fuel nozzle receiving further heat from the compression heat which results from pressurization of the oxidant. The combustor unit includes an inner combustor sleeve whose inner wall defines the combustion zone. The inner combustor sleeve is surrounded by two concentric water channels, one defined by the space between the inner combustor sleeve and an intermediate sleeve, and the second defined by the space between the intermediate sleeve and an outer cylindrical housing. The channels are connected by an annular passage adjacent the top of the combustor assembly and the countercurrent nature of the water flow provides efficient cooling of the inner combustor sleeve. An annular water ejector with a plurality of nozzles is provided to direct water downwardly into the combustor unit at the boundary of the combustion zone and along the lower section of the intermediate sleeve.

  13. SIMS prototype system 1 test results: Engineering analysis

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The space and domestic water solar heating system designated SIMS Prototype Systems 1 was evaluated. The test system used 720 ft (gross) of Solar Energy Products Air Collectors, a Solar Control Corporation SAM 20 Air Handler with Model 75-175 control unit, a Jackson Solar Storage tank with Rho Sigma Mod 106 controller, and 20 tons of rack storage. The test data analysis performed evaluates the system performance and documents the suitability of SIMS Prototype System 1 hardware for field installation.

  14. Development of a high speed extrusion concept using a floating screw sleeve for solid-melt-separation

    NASA Astrophysics Data System (ADS)

    Karrenberg, Gregor; Wortberg, Johannes

    2015-05-01

    The High-Speed-S-Truder with floating screw sleeve is an alternative extrusion concept with solid-melt-separation. A fairly conventional 35 mm screw with a length of 21 D, which is accelerated by a 75 kW gearless, water cooled synchronous drive, conveys the resin into a 60 mm screw sleeve with a length of 10 D. Inside the sleeve the material is plasticizied and discharged into the outer screw channel of the sleeve through radial bores. Only the solid bed remains inside. The development of a melt pool - and thus a decrease of the plasticizing capacity - is avoided. The sleeve is rotated by drag forces only (approximately 10 - 15 % of the screw speed). Due to the low speed of the screw sleeve molten material is conveyed to a 4 D Dynamic Mixing Ring in a gentle manner. The DMRs floating ring and the screw sleeve are directly coupled. The granules in the screw channel are stopped by a barrier on the screw in front of the mixing device. So nearly no unmelted material can pass the system. For temperature management in the plastification and mixing zone a 3-zone heating/air-cooling system is used. Various kinds of experiments with the High-Speed S-Truder were conducted. Reachable throughputs with different types of material (LDPE, LLDPE, PP, PS) have been tested. Also three screw geometries, which are mainly varying in the channel depth, were compared. Experimental results and theoretical background will be described in this paper.

  15. Effect of Laparoscopic Sleeve Gastrectomy vs Laparoscopic Roux-en-Y Gastric Bypass on Weight Loss at 5 Years Among Patients With Morbid Obesity: The SLEEVEPASS Randomized Clinical Trial.

    PubMed

    Salminen, Paulina; Helmiö, Mika; Ovaska, Jari; Juuti, Anne; Leivonen, Marja; Peromaa-Haavisto, Pipsa; Hurme, Saija; Soinio, Minna; Nuutila, Pirjo; Victorzon, Mikael

    2018-01-16

    Laparoscopic sleeve gastrectomy for treatment of morbid obesity has increased substantially despite the lack of long-term results compared with laparoscopic Roux-en-Y gastric bypass. To determine whether laparoscopic sleeve gastrectomy and laparoscopic Roux-en-Y gastric bypass are equivalent for weight loss at 5 years in patients with morbid obesity. The Sleeve vs Bypass (SLEEVEPASS) multicenter, multisurgeon, open-label, randomized clinical equivalence trial was conducted from March 2008 until June 2010 in Finland. The trial enrolled 240 morbidly obese patients aged 18 to 60 years, who were randomly assigned to sleeve gastrectomy or gastric bypass with a 5-year follow-up period (last follow-up, October 14, 2015). Laparoscopic sleeve gastrectomy (n = 121) or laparoscopic Roux-en-Y gastric bypass (n = 119). The primary end point was weight loss evaluated by percentage excess weight loss. Prespecified equivalence margins for the clinical significance of weight loss differences between gastric bypass and sleeve gastrectomy were -9% to +9% excess weight loss. Secondary end points included resolution of comorbidities, improvement of quality of life (QOL), all adverse events (overall morbidity), and mortality. Among 240 patients randomized (mean age, 48 [SD, 9] years; mean baseline body mass index, 45.9, [SD, 6.0]; 69.6% women), 80.4% completed the 5-year follow-up. At baseline, 42.1% had type 2 diabetes, 34.6% dyslipidemia, and 70.8% hypertension. The estimated mean percentage excess weight loss at 5 years was 49% (95% CI, 45%-52%) after sleeve gastrectomy and 57% (95% CI, 53%-61%) after gastric bypass (difference, 8.2 percentage units [95% CI, 3.2%-13.2%], higher in the gastric bypass group) and did not meet criteria for equivalence. Complete or partial remission of type 2 diabetes was seen in 37% (n = 15/41) after sleeve gastrectomy and in 45% (n = 18/40) after gastric bypass (P > .99). Medication for dyslipidemia was discontinued in 47% (n = 14/30) after sleeve gastrectomy and 60% (n = 24/40) after gastric bypass (P = .15) and for hypertension in 29% (n = 20/68) and 51% (n = 37/73) (P = .02), respectively. There was no statistically significant difference in QOL between groups (P = .85) and no treatment-related mortality. At 5 years the overall morbidity rate was 19% (n = 23) for sleeve gastrectomy and 26% (n = 31) for gastric bypass (P = .19). Among patients with morbid obesity, use of laparoscopic sleeve gastrectomy compared with use of laparoscopic Roux-en-Y gastric bypass did not meet criteria for equivalence in terms of percentage excess weight loss at 5 years. Although gastric bypass compared with sleeve gastrectomy was associated with greater percentage excess weight loss at 5 years, the difference was not statistically significant, based on the prespecified equivalence margins. clinicaltrials.gov Identifier: NCT00793143.

  16. Electrochemical Deburring

    NASA Technical Reports Server (NTRS)

    Burley, R. K.

    1983-01-01

    Electrochemical deburring removes burrs from assembled injector tubes. Since process uses liquid anodic dissolution in liquid electrolyte to proide deburring action, smoothes surfaces and edges in otherwise inaccessible areas. Tool consists of sleeve that contains metallic ring cathode. Sleeve is placed over tube, and electrolytic solution is forced to flow between tube and sleeve. The workpiece serves an anode.

  17. 78 FR 14934 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-08

    ... discrepancies of the wiring and surrounding Teflon sleeves of the fuel tank boost pumps and override/jettison... the wiring and sleeves with new parts, as necessary. The first SNPRM proposed to reduce the initial... inspections to detect discrepancies of the wiring and surrounding Teflon sleeves of the fuel tank boost pumps...

  18. Technology demonstration for reducing mercury emissions from small-scale gold refining facilities.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habegger, L. J.; Fernandez, L. E.; Engle, M.

    2008-06-30

    Gold that is brought from artisanal and small-scale gold mining areas to gold shops for processing and sale typically contains 5-40% mercury. The uncontrolled removal of the residual mercury in gold shops by using high-temperature evaporation can be a significant source of mercury emissions in urban areas where the shops are located. Emissions from gold shop hoods during a burn can exceed 1,000 mg/m{sup 3}. Because the saturation concentration of mercury vapor at operating temperatures at the hood exhaust is less than 100 mg/m{sup 3}, the dominant component of the exhaust is in the form of aerosol or liquid particles.more » The U.S. Environmental Protection Agency (EPA), with technical support from Argonne National Laboratory (Argonne), has completed a project to design and test a technology to remove the dominant aerosol component in the emissions from gold shops. The objective was to demonstrate a technology that could be manufactured at low cost and by using locally available materials and manufacturing capabilities. Six prototypes designed by Argonne were locally manufactured, installed, and tested in gold shops in Itaituba and Creporizao, Brazil. The initial prototype design incorporated a pebble bed as the media for collecting the mercury aerosols, and a mercury collection efficiency of over 90% was demonstrated. Though achieving high efficiencies, the initial prototype was determined to have practical disadvantages such as excessive weight, a somewhat complex construction, and high costs (>US$1,000). To further simplify the construction, operation, and associated costs, a second prototype design was developed in which the pebble bed was replaced with slotted steel baffle plates. The system was designed to have flexibility for installation in various hood configurations. The second prototype with the baffle plate design was installed and tested in several different hood/exhaust systems to determine the optimal installation configuration. The significance of coagulation and collection of the mercury aerosols in exhaust ducts, which is dependent on the hood and collector configuration, was also evaluated. Prototype demonstration tests verified the theoretical basis for mercury aerosol capture that can be used to optimize the baffle plate design, flow rates, and hood exhaust ducts and plenum to achieve 80% or higher removal efficiencies. Results indicated that installation configuration significantly influences a system's capture efficiency. Configurations that retained existing inlet ducts resulted in system efficiencies of more than 80%, whereas installation configurations without inlet ducts significantly reduced capture efficiency. As an alternative to increasing the volume of inlet ducts, the number of baffle plates in the system baffle assembly could be doubled to increase efficiency. Recommended installation and operation procedures were developed on the basis of these results. A water-based mercury capture system developed in Indonesia for installation in smaller shops was also tested and shown to be effective for certain applications. The cost of construction and installation of the baffle plate prototype was approximately US$400. These costs were reported as acceptable by local gold shop owners and government regulators, and were significantly lower than the cost of an alternate charcoal/copper mesh mercury filter available in the region, which costs about US$10,000. A sampling procedure that consists of a particle filter combined with a vapor analyzer was demonstrated as an effective procedure for analyzing both the aerosol and vapor components of the mercury concentrations. Two key findings for enhancing higher mercury collection were identified. First, the aerosol/vapor mercury emissions must be given sufficient time for the mercury particles to coagulate to a size that can be readily captured by the baffle plates. An interval of at least 6 seconds of transit time between the point of evaporation and contact with the slotted baffle plates is recommended. Some particles will also deposit in the exhaust ducts between the point of evaporation and the baffle plates. Second, the slots in the baffle plates create jets that force the mercury particles to impinge and adhere on downstream surfaces. The baffle plates should closely follow the designs developed for this system to be most effective.« less

  19. Seamless metal-clad fiber-reinforced organic matrix composite structures and process for their manufacture

    NASA Technical Reports Server (NTRS)

    Bluck, Raymond M. (Inventor); Bush, Harold G. (Inventor); Johnson, Robert R. (Inventor)

    1990-01-01

    A metallic outer sleeve is provided which is capable of enveloping a hollow metallic inner member having continuous reinforcing fibers attached to the distal end thereof. The inner member is then introduced into outer sleeve until inner member is completely enveloped by outer sleeve. A liquid matrix member is then injected into space between inner member and outer sleeve. A pressurized heat transfer medium is flowed through the inside of inner member, thereby forming a fiber reinforced matrix composite material. The wall thicknesses of both inner member and outer sleeve are then reduced to the appropriate size by chemical etching, to adjust the thermal expansion coefficient of the metal-clad composite structure to the desired value. thereby forming a fiber reinforced matrix composite material. The wall thicknesses of both inner member and outer sleeve are then reduced to the appropriate size by chemical etching, to adjust the thermal expansion coefficient of the metal-clad composite structure to the desired value. The novelty of this invention resides in the development of a efficient method of producing seamless metal clad fiber reinforced organic matrix composite structures.

  20. Method and apparatus for extracting tritium and preparing radioactive waste for disposal

    DOEpatents

    Heung, Leung K.

    1994-01-01

    Apparatus for heating an object such as a nuclear target bundle to release and recover hydrogen and contain the disposable residue for disposal. The apparatus comprises an inverted furnace, a sleeve/crucible assembly for holding and enclosing the bundle, conveying equipment for placing the sleeve onto the crucible and loading the bundle into the sleeve/crucible, a lift for raising the enclosed bundle into the furnace, and hydrogen recovery equipment including a trap and strippers, all housed in a containment having negative internal pressure. The crucible/sleeve assembly has an internal volume that is sufficient to enclose and hold the bundle before heating; the crucible's internal volume is sufficient by itself to hold and enclose the bundle's volume after heating. The crucible can then be covered and disposed of; the sleeve, on the other hand, can be reused.

  1. Apparatus and method for sealing perforated well casing

    DOEpatents

    Blount, Curtis G.; Benham, Robert A.; Brock, Jerry L.; Emerson, John A.; Ferguson, Keith R.; Scheve, Donald F.; Schmidt, Joseph H.; Schuler, Karl W.; Stanton, Philip L.

    1997-01-01

    Perforations and other openings in well casings, liners and other conduits may be substantially blocked or sealed to prevent fluid flow between the casing or liner interior and an earth formation by placing a radially expansible sleeve adjacent the perforations or openings and urging the sleeve into forcible engagement with the casing or inner wall using an explosive charge. An apparatus including a radially contracted sleeve formed by a coiled plate member or a tubular member having flutes defined by external and internal folds, may be deployed into a well casing or liner through a production or injection tubing string and on the end of a flexible cable or coilable tubing. An explosive charge disposed on the apparatus and within the sleeve may be detonated to urge the sleeve into forcible engagement with the casing inner wall.

  2. Apparatus and method for sealing perforated well casing

    DOEpatents

    Blount, C.G.; Benham, R.A.; Brock, J.L.; Emerson, J.A.; Ferguson, K.R.; Scheve, D.F.; Schmidt, J.H.; Schuler, K.W.; Stanton, P.L.

    1997-03-25

    Perforations and other openings in well casings, liners and other conduits may be substantially blocked or sealed to prevent fluid flow between the casing or liner interior and an earth formation by placing a radially expansible sleeve adjacent the perforations or openings and urging the sleeve into forcible engagement with the casing or inner wall using an explosive charge. An apparatus including a radially contracted sleeve formed by a coiled plate member or a tubular member having flutes defined by external and internal folds, may be deployed into a well casing or liner through a production or injection tubing string and on the end of a flexible cable or coilable tubing. An explosive charge disposed on the apparatus and within the sleeve may be detonated to urge the sleeve into forcible engagement with the casing inner wall. 17 figs.

  3. Intraoperative fracture of phacoemulsification sleeve

    PubMed Central

    2010-01-01

    Background We describe a case of intraoperative fracture of phacoemulsification sleeve during phacoemulsification surgery. Case presentation Phacoemulsification surgery was performed in the left eye of a 58-year-old lady with grade II nuclear sclerosis & grade I cortical cataract. Towards the end of quadrant removal, there was anterior chamber instability with impaired followability of nuclear fragments. The distal part of the fractured sleeve remained inside the anterior chamber upon removal of the phacoemulsification probe. The retained sleeve was retrieved with a pair of forceps through the corneal incision site, which did not require widening. There was no missing fragments retained intraocularly and the patient had an uneventful recovery with vision of 20/25 at three months post-operatively. Conclusion Phacoemulsification sleeve fracture is an uncommon complication. With early identification of this condition and proper management, major complications can be avoided. PMID:21118542

  4. Sleeve gastrectomy effects on hunger, satiation, and gastrointestinal hormone and motility responses after a liquid meal test.

    PubMed

    Mans, Esther; Serra-Prat, Mateu; Palomera, Elisabet; Suñol, Xavier; Clavé, Pere

    2015-09-01

    The relation between hunger, satiation, and integrated gastrointestinal motility and hormonal responses in morbidly obese patients after sleeve gastrectomy has not been determined. The objective was to assess the effects of sleeve gastrectomy on hunger, satiation, gastric and gallbladder motility, and gastrointestinal hormone response after a liquid meal test. Three groups were studied: morbidly obese patients (n = 16), morbidly obese patients who had had sleeve gastrectomy (n = 8), and nonobese patients (n = 16). The participants fasted for 10 h and then consumed a 200-mL liquid meal (400 kcal + 1.5 g paracetamol). Fasting and postprandial hunger, satiation, hormone concentrations, and gastric and gallbladder emptying were measured several times over 4 h. No differences were observed in hunger and satiation curves between morbidly obese and nonobese groups; however, sleeve gastrectomy patients were less hungry and more satiated than the other groups. Antrum area during fasting in morbidly obese patients was statistically significant larger than in the nonobese and sleeve gastrectomy groups. Gastric emptying was accelerated in the sleeve gastrectomy group compared with the other 2 groups (which had very similar results). Gallbladder emptying was similar in the 3 groups. Sleeve gastrectomy patients showed the lowest ghrelin concentrations and higher early postprandial cholecystokinin and glucagon-like peptide 1 peaks than did the other participants. This group also showed an improved insulin resistance pattern compared with morbidly obese patients. Sleeve gastrectomy seems to be associated with profound changes in gastrointestinal physiology that contribute to reducing hunger and increasing sensations of satiation. These changes include accelerated gastric emptying, enhanced postprandial cholecystokinin and glucagon-like peptide 1 concentrations, and reduced ghrelin release, which together may help patients lose weight and improve their glucose metabolism after surgery. This trial was registered at clinicaltrials.gov as NCT02414893. © 2015 American Society for Nutrition.

  5. Design of a Soft Robotic Elbow Sleeve with Passive and Intent-Controlled Actuation

    PubMed Central

    Koh, Tze Hui; Cheng, Nicholas; Yap, Hong Kai; Yeow, Chen-Hua

    2017-01-01

    The provision of continuous passive, and intent-based assisted movements for neuromuscular training can be incorporated into a robotic elbow sleeve. The objective of this study is to propose the design and test the functionality of a soft robotic elbow sleeve in assisting flexion and extension of the elbow, both passively and using intent-based motion reinforcement. First, the elbow sleeve was developed, using elastomeric and fabric-based pneumatic actuators, which are soft and lightweight, in order to address issues of non-portability and poor alignment with joints that conventional robotic rehabilitation devices are faced with. Second, the control system was developed to allow for: (i) continuous passive actuation, in which the actuators will be activated in cycles, alternating between flexion and extension; and (ii) an intent-based actuation, in which user intent is detected by surface electromyography (sEMG) sensors attached to the biceps and triceps, and passed through a logic sequence to allow for flexion or extension of the elbow. Using this setup, the elbow sleeve was tested on six healthy subjects to assess the functionality of the device, in terms of the range of motion afforded by the device while in the continuous passive actuation. The results showed that the elbow sleeve is capable of achieving approximately 50% of the full range of motion of the elbow joint among all subjects. Next, further experiments were conducted to test the efficacy of the intent-based actuation on these healthy subjects. The results showed that all subjects were capable of achieving electromyography (EMG) control of the elbow sleeve. These preliminary results show that the elbow sleeve is capable of carrying out continuous passive and intent-based assisted movements. Further investigation of the clinical implementation of the elbow sleeve for the neuromuscular training of neurologically-impaired persons, such as stroke survivors, is needed. PMID:29118693

  6. What matters after sleeve gastrectomy: patient characteristics or surgical technique?

    PubMed

    Dhar, Vikrom K; Hanseman, Dennis J; Watkins, Brad M; Paquette, Ian M; Shah, Shimul A; Thompson, Jonathan R

    2018-03-01

    The impact of operative technique on outcomes in laparoscopic sleeve gastrectomy has been explored previously; however, the relative importance of patient characteristics remains unknown. Our aim was to characterize national variability in operative technique for laparoscopic sleeve gastrectomy and determine whether patient-specific factors are more critical to predicting outcomes. We queried the database of the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program for laparoscopic sleeve gastrostomies performed in 2015 (n = 88,845). Logistic regression models were used to determine predictors of postoperative outcomes. In 2015, >460 variations of laparoscopic sleeve gastrectomy were performed based on combinations of bougie size, distance from the pylorus, use of staple line reinforcement, and oversewing of the staple line. Despite such substantial variability, technique variants were not predictive of outcomes, including perioperative morbidity, leak, or bleeding (all P ≥ .05). Instead, preoperative patient characteristics were found to be more predictive of these outcomes after laparoscopic sleeve gastrectomy. Only history of gastroesophageal disease (odds ratio 1.44, 95% confidence interval 1.08-1.91, P < .01) was associated with leak. Considerable variability exists in technique among surgeons nationally, but patient characteristics are more predictive of adverse outcomes after laparoscopic sleeve gastrectomy. Bundled payments and reimbursement policies should account for patient-specific factors in addition to current accreditation and volume thresholds when deciding risk-adjustment strategies. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Homopolar machine for reversible energy storage and transfer systems

    DOEpatents

    Stillwagon, Roy E.

    1978-01-01

    A homopolar machine designed to operate as a generator and motor in reversibly storing and transferring energy between the machine and a magnetic load coil for a thermo-nuclear reactor. The machine rotor comprises hollow thin-walled cylinders or sleeves which form the basis of the system by utilizing substantially all of the rotor mass as a conductor thus making it possible to transfer substantially all the rotor kinetic energy electrically to the load coil in a highly economical and efficient manner. The rotor is divided into multiple separate cylinders or sleeves of modular design, connected in series and arranged to rotate in opposite directions but maintain the supply of current in a single direction to the machine terminals. A stator concentrically disposed around the sleeves consists of a hollow cylinder having a number of excitation coils each located radially outward from the ends of adjacent sleeves. Current collected at an end of each sleeve by sleeve slip rings and brushes is transferred through terminals to the magnetic load coil. Thereafter, electrical energy returned from the coil then flows through the machine which causes the sleeves to motor up to the desired speed in preparation for repetition of the cycle. To eliminate drag on the rotor between current pulses, the brush rigging is designed to lift brushes from all slip rings in the machine.

  8. Homopolar machine for reversible energy storage and transfer systems

    DOEpatents

    Stillwagon, Roy E.

    1981-01-01

    A homopolar machine designed to operate as a generator and motor in reversibly storing and transferring energy between the machine and a magnetic load coil for a thermo-nuclear reactor. The machine rotor comprises hollow thin-walled cylinders or sleeves which form the basis of the system by utilizing substantially all of the rotor mass as a conductor thus making it possible to transfer substantially all the rotor kinetic energy electrically to the load coil in a highly economical and efficient manner. The rotor is divided into multiple separate cylinders or sleeves of modular design, connected in series and arranged to rotate in opposite directions but maintain the supply of current in a single direction to the machine terminals. A stator concentrically disposed around the sleeves consists of a hollow cylinder having a number of excitation coils each located radially outward from the ends of adjacent sleeves. Current collected at an end of each sleeve by sleeve slip rings and brushes is transferred through terminals to the magnetic load coil. Thereafter, electrical energy returned from the coil then flows through the machine which causes the sleeves to motor up to the desired speed in preparation for repetition of the cycle. To eliminate drag on the rotor between current pulses, the brush rigging is designed to lift brushes from all slip rings in the machine.

  9. Information and Communications Technology (ICT) Infrastructure for the ASTRI SST-2M telescope prototype for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Gianotti, F.; Tacchini, A.; Leto, G.; Martinetti, E.; Bruno, P.; Bellassai, G.; Conforti, V.; Gallozzi, S.; Mastropietro, M.; Tanci, C.; Malaguti, G.; Trifoglio, M.

    2016-08-01

    The Cherenkov Telescope Array (CTA) represents the next generation of ground-based observatories for very high energy gamma-ray astronomy. The CTA will consist of two arrays at two different sites, one in the northern and one in the southern hemisphere. The current CTA design foresees, in the southern site, the installation of many tens of imaging atmospheric Cherenkov telescopes of three different classes, namely large, medium and small, so defined in relation to their mirror area; the northern hemisphere array would consist of few tens of the two larger telescope types. The Italian National Institute for Astrophysics (INAF) is developing the Cherenkov Small Size Telescope ASTRI SST- 2M end-to-end prototype telescope within the framework of the International Cherenkov Telescope Array (CTA) project. The ASTRI prototype has been installed at the INAF observing station located in Serra La Nave on Mt. Etna, Italy. Furthermore a mini-array, composed of nine of ASTRI telescopes, has been proposed to be installed at the Southern CTA site. Among the several different infrastructures belonging the ASTRI project, the Information and Communication Technology (ICT) equipment is dedicated to operations of computing and data storage, as well as the control of the entire telescope, and it is designed to achieve the maximum efficiency for all performance requirements. Thus a complete and stand-alone computer centre has been designed and implemented. The goal is to obtain optimal ICT equipment, with an adequate level of redundancy, that might be scaled up for the ASTRI mini-array, taking into account the necessary control, monitor and alarm system requirements. In this contribution we present the ICT equipment currently installed at the Serra La Nave observing station where the ASTRI SST-2M prototype will be operated. The computer centre and the control room are described with particular emphasis on the Local Area Network scheme, the computing and data storage system, and the telescope control and monitoring.

  10. 78 FR 17082 - Airworthiness Directives; Rolls-Royce Deutschland Ltd & Co KG Turbojet Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-20

    ... flight. (5) If you find any broken bolt in the HPT shaft air seal sleeve, visually inspect the HPT stage... assembly, high pressure turbine (HPT) bearing support assembly and HPT air seal sleeve bolts identified... turbine (HPT) bearing support assembly, and HPT air seal sleeve within 100 engine cycles-in-service. (2...

  11. Safety valve

    DOEpatents

    Bergman, Ulf C.

    1984-01-01

    The safety valve contains a resilient gland to be held between a valve seat and a valve member and is secured to the valve member by a sleeve surrounding the end of the valve member adjacent to the valve seat. The sleeve is movable relative to the valve member through a limited axial distance and a gap exists between said valve member and said sleeve.

  12. Test of prototype ITER vacuum ultraviolet spectrometer and its application to impurity study in KSTAR plasmas.

    PubMed

    Seon, C R; Hong, J H; Jang, J; Lee, S H; Choe, W; Lee, H H; Cheon, M S; Pak, S; Lee, H G; Biel, W; Barnsley, R

    2014-11-01

    To optimize the design of ITER vacuum ultraviolet (VUV) spectrometer, a prototype VUV spectrometer was developed. The sensitivity calibration curve of the spectrometer was calculated from the mirror reflectivity, the grating efficiency, and the detector efficiency. The calibration curve was consistent with the calibration points derived in the experiment using the calibrated hollow cathode lamp. For the application of the prototype ITER VUV spectrometer, the prototype spectrometer was installed at KSTAR, and various impurity emission lines could be measured. By analyzing about 100 shots, strong positive correlation between the O VI and the C IV emission intensities could be found.

  13. STS-40 DTO 647 prototype filter documented under OV-102's middeck subfloor

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-40 Detailed Test Objective (DTO) 647, Water Separator Filter Performance Evaluation, prototype filter installed at the inlet of the water separator is documented under middeck subfloor aboard Columbia, Orbiter Vehicle (OV) 102. The proposed filter is being tested for its ability to remove debris from the air/water stream coming from the cabin heat exchanger.

  14. Staple line reinforcement during sleeve gastrectomy with a new type of reinforced stapler.

    PubMed

    El Moussaoui, Imad; Limbga, Augustin; Mehdi, Abdelilah

    2018-04-01

    Bleeding and staple-line leak, are the most common complications of laparoscopic sleeve gastrectomy. To decrease the incidence of this complications, a variety of intraoperative reinforcement of staple line is used. Reinforced GIA™ is a new automatic suture device with pre-attached synthetic tissue reinforcement, but no study has evaluated its use in sleeve gastrectomy. The objective of this study is to evaluate the efficacy and safety of this new staple line reinforcement technique in laparoscopic sleeve gastrectomy. We conducted a retrospective review of 290 patients who underwent laparoscopic sleeve gastrectomy between January 2013 and January 2016 in which reinforced GIA™ or standard GIA™ was used. Patients preoperative characteristics, Operative time, staple line leaks, staple line bleeds, stenosis, and complications requiring reoperation were collected. A total of 187 laparoscopic sleeve gastrectomy were performed with standard GIA and 103 with reinforced GIA™. Patient characteristics were not significantly different between the groups. The average operating time in the standard GIA group is 57.41±16.44 min against 50.9±14.12 min in the reinforced GIA group (P=0.006). Two staple line leaks developed in the standard GIA group and reoperated against no patients in the reinforced GIA group, without significant difference between the both groups (P=0.66). Staple line bleeds are less in the reinforced GIA group, only 23 (22.3%) against 78 (41.7%) cases in the standard GIA group (P=0.001). No patients of both groups developed gastric sleeve stenosis. During laparoscopic sleeve gastrectomy, the use of a reinforced stapler significantly reduces the operative time and staple line bleeding. No significant difference is evidenced in terms of reduction of staple line leaks with this reinforced stapler.

  15. Method and apparatus for extracting tritium and preparing radioactive waste for disposal

    DOEpatents

    Heung, L.K.

    1994-03-29

    Apparatus is described for heating an object such as a nuclear target bundle to release and recover hydrogen and contain the disposable residue for disposal. The apparatus comprises an inverted furnace, a sleeve/crucible assembly for holding and enclosing the bundle, conveying equipment for placing the sleeve onto the crucible and loading the bundle into the sleeve/crucible, a lift for raising the enclosed bundle into the furnace, and hydrogen recovery equipment including a trap and strippers, all housed in a containment having negative internal pressure. The crucible/sleeve assembly has an internal volume that is sufficient to enclose and hold the bundle before heating; the crucible's internal volume is sufficient by itself to hold and enclose the bundle's volume after heating. The crucible can then be covered and disposed of; the sleeve, on the other hand, can be reused. 4 figures.

  16. Development of on line automatic separation device for apple and sleeve

    NASA Astrophysics Data System (ADS)

    Xin, Dengke; Ning, Duo; Wang, Kangle; Han, Yuhang

    2018-04-01

    Based on STM32F407 single chip microcomputer as control core, automatic separation device of fruit sleeve is designed. This design consists of hardware and software. In hardware, it includes mechanical tooth separator and three degree of freedom manipulator, as well as industrial control computer, image data acquisition card, end effector and other structures. The software system is based on Visual C++ development environment, to achieve localization and recognition of fruit sleeve with the technology of image processing and machine vision, drive manipulator of foam net sets of capture, transfer, the designated position task. Test shows: The automatic separation device of the fruit sleeve has the advantages of quick response speed and high separation success rate, and can realize separation of the apple and plastic foam sleeve, and lays the foundation for further studying and realizing the application of the enterprise production line.

  17. Iatrogenic injury of the intrathoracic oesophagus with bougie during sleeve gastrectomy

    PubMed Central

    Signorini, Franco José; Verónica, Gorodner; Marcos, Marani; German, Viscido; Federico, Moser

    2018-01-01

    One of the most popular procedures amongst obesity surgery is the sleeve gastrectomy. There is international consensus regarding the usage of bougie for sleeve gastrectomy calibration. Nevertheless, there is a dissociation between the number of oesophageal perforations reported for any other oesophageal/gastric operation that requires bougie (e.g., anti-reflux surgery, incidence 1.2%) and bariatric surgery, where this complication seems to be almost a myth. Interestingly enough, the number of bariatric procedures is much higher than any other oesophageal/gastric surgery. This suggests that oesophageal perforations in obesity surgery are underreported. We report a case of injury of the intrathoracic oesophagus with bougie that occurred during a sleeve gastrectomy. In the infrequent case that the perforation is diagnosed during surgery, primary repair during the same intervention is highly recommended. Videothoracoscopy might be an effective option in case of necessity. We were able to complete the sleeve gastrectomy without increasing morbidity. PMID:28695879

  18. Stemless ball valve

    NASA Technical Reports Server (NTRS)

    Burgess, Kevin (Inventor); Yakos, David (Inventor); Walthall, Bryan (Inventor)

    2012-01-01

    A stemless ball valve comprising: a right flange; left flange; ball with an axis pin and two travel pins; ball seal on either side of the ball; guide sleeve with inner walls comprising two channels; cartridge guide holder; inner magnetic cartridge; and outer magnetic cartridge. The ball is situated inside of the guide sleeve, and a travel pin is located in each of the two channels. The guide sleeve is situated inside of the cartridge guide holder, which is located adjacent to and outside of the inner magnetic cartridge and secured to the inner magnetic cartridge such that when the inner magnetic cartridge rotates, the cartridge guide holder also rotates. The cartridge guide holder is secured to the guide sleeve such that when the cartridge guide holder rotates, the travel pins move within the channels in the inner walls of the guide sleeve, thereby causing the ball to rotate.

  19. Thermodynamic Alerter for Microbursts (TAMP)

    NASA Technical Reports Server (NTRS)

    Eccles, Peter J.

    1991-01-01

    The following subject areas are covered: microburst detection, location and measurement; thermal alerter for microbursts prototypes (TAMP); sensor-transmitters (Senstrans) design; TAMP installation; and DAPAD software.

  20. QUICK DISCONNECT ELECTRICAL CONNECTOR

    DOEpatents

    None

    1962-08-14

    A remotely actuated quick-dlsconnect electrical connector which comprises a pair of mating portrons releasably retained together by a bayonet- type joint with a rotatable sleeve on one of the mating portions providing for engagement and disengagement of the joint is described. A lanyard with ends passed through fulcrums and affixed to the sleeve erfects rotation of the sleeve and disengages the joint. (AEC)

  1. WELDING TORCH

    DOEpatents

    Correy, T.B.

    1961-10-01

    A welding torch into which water and inert gas are piped separately for cooling and for providing a suitable gaseous atmosphere is described. A welding electrode is clamped in the torch by a removable collet sleeve and a removable collet head. Replacement of the sleeve and head with larger or smaller sleeve and head permits a larger or smaller welding electrode to be substituted on the torch. (AEC)

  2. Directly susceptible, noncarbon metal ceramic composite crucible

    DOEpatents

    Holcombe, Jr., Cressie E.; Kiggans, Jr., James O.; Morrow, S. Marvin; Rexford, Donald

    1999-01-01

    A sintered metal ceramic crucible suitable for high temperature induction melting of reactive metals without appreciable carbon or silicon contamination of the melt. The crucible comprises a cast matrix of a thermally conductive ceramic material; a perforated metal sleeve, which serves as a susceptor for induction heating of the crucible, embedded within the ceramic cast matrix; and a thermal-shock-absorber barrier interposed between the metal sleeve and the ceramic cast matrix to allow for differential thermal expansions between the matrix and the metal sleeve and to act as a thermal-shock-absorber which moderates the effects of rapid changes of sleeve temperature on the matrix.

  3. REMOTELY OPERATED MANIPULATOR

    DOEpatents

    Hutto, E.L.

    1961-08-15

    A manipulator is described for performing, within an entirely enclosed cell containling radioactive materials, various mechanical operations. A rod with flexible fingers is encompassed by a tubular sleeve shorter than the rod. Relative movement between the rod and sleeve causes the fingers to open and close. This relative movement is effected by relative movement of permanent magnets in magnetic coupling relation to magnetic followers affixed to the ends of the rod and sleeve. The rod and its sleeve may be moved as a unit axially or may be rotated by means of the magnetic couplings. The manipulator is enclosed within a tubular member which is flexibly sealed to an opening in the cell. (AEC)

  4. Hybrid video-assisted thoracic surgery with segmental-main bronchial sleeve resection for non-small cell lung cancer.

    PubMed

    Li, Shuben; Chai, Huiping; Huang, Jun; Zeng, Guangqiao; Shao, Wenlong; He, Jianxing

    2014-04-01

    The purpose of the current study is to present the clinical and surgical results in patients who underwent hybrid video-assisted thoracic surgery with segmental-main bronchial sleeve resection. Thirty-one patients, 27 men and 4 women, underwent segmental-main bronchial sleeve anastomoses for non-small cell lung cancer between May 2004 and May 2011. Twenty-six (83.9%) patients had squamous cell carcinoma, and 5 patients had adenocarcinoma. Six patients were at stage IIB, 24 patients at stage IIIA, and 1 patient at stage IIIB. Secondary sleeve anastomosis was performed in 18 patients, and Y-shaped multiple sleeve anastomosis was performed in 8 patients. Single segmental bronchiole anastomosis was performed in 5 cases. The average time for chest tube removal was 5.6 days. The average length of hospital stay was 11.8 days. No anastomosis fistula developed in any of the patients. The 1-, 2-, and 3-year survival rates were 83.9%, 71.0%, and 41.9%, respectively. Hybrid video-assisted thoracic surgery with segmental-main bronchial sleeve resection is a complex technique that requires training and experience, but it is an effective and safe operation for selected patients.

  5. Gesture-Based Robot Control with Variable Autonomy from the JPL Biosleeve

    NASA Technical Reports Server (NTRS)

    Wolf, Michael T.; Assad, Christopher; Vernacchia, Matthew T.; Fromm, Joshua; Jethani, Henna L.

    2013-01-01

    This paper presents a new gesture-based human interface for natural robot control. Detailed activity of the user's hand and arm is acquired via a novel device, called the BioSleeve, which packages dry-contact surface electromyography (EMG) and an inertial measurement unit (IMU) into a sleeve worn on the forearm. The BioSleeve's accompanying algorithms can reliably decode as many as sixteen discrete hand gestures and estimate the continuous orientation of the forearm. These gestures and positions are mapped to robot commands that, to varying degrees, integrate with the robot's perception of its environment and its ability to complete tasks autonomously. This flexible approach enables, for example, supervisory point-to-goal commands, virtual joystick for guarded teleoperation, and high degree of freedom mimicked manipulation, all from a single device. The BioSleeve is meant for portable field use; unlike other gesture recognition systems, use of the BioSleeve for robot control is invariant to lighting conditions, occlusions, and the human-robot spatial relationship and does not encumber the user's hands. The BioSleeve control approach has been implemented on three robot types, and we present proof-of-principle demonstrations with mobile ground robots, manipulation robots, and prosthetic hands.

  6. Construction and operation of a support facilities (Building 729) for operation/testing of a prototype accelerator/storage ring (XLS) and machine shop for the National Synchrotron Light Source at Brookhaven National Laboratory, Upton, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-06-01

    Proposed action is to construct at BNL a 5,600-ft[sup 2] support building, install and operate a prototypic 200 MeV accelerator and a prototypic 700 MeV storage ring within, and to construct and operate a 15 kV substation to power the building. The accelerator and storage ring would comprise the x-ray lithography source or XLS.

  7. Construction and operation of a support facilities (Building 729) for operation/testing of a prototype accelerator/storage ring (XLS) and machine shop for the National Synchrotron Light Source at Brookhaven National Laboratory, Upton, New York. Environmental assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-06-01

    Proposed action is to construct at BNL a 5,600-ft{sup 2} support building, install and operate a prototypic 200 MeV accelerator and a prototypic 700 MeV storage ring within, and to construct and operate a 15 kV substation to power the building. The accelerator and storage ring would comprise the x-ray lithography source or XLS.

  8. Design and fabrication of a flexible tunnel for Sortie Laboratory

    NASA Technical Reports Server (NTRS)

    1975-01-01

    A program was conducted to update a prototype design and to fabricate a flexible tunnel for a space shuttle/spacelab interface structure. The significant changes in the prototype are as follows: (1) elimination of foam from bladder laminate to increase bladder flexibility, (2) heat treat pulley brackets, bolts, and hinge pin to 160,000 psi minimum tensile strength, and (3) reduction of the meteoroid barrier from 0.5 inch to 0.375 inch. The thermal blanket installation study resulted in developing a method of installation by properly folding the various layers so that a uniform thickness could be maintained under the clamps. A single-lobe mockup was fabricated and cycled open and closed several times with no apparent damage to the blanket.

  9. A Delphi Consensus of the Crucial Steps in Gastric Bypass and Sleeve Gastrectomy Procedures in the Netherlands.

    PubMed

    Kaijser, Mirjam A; van Ramshorst, Gabrielle H; Emous, Marloes; Veeger, Nic J G M; van Wagensveld, Bart A; Pierie, Jean-Pierre E N

    2018-04-09

    Bariatric procedures are technically complex and skill demanding. In order to standardize the procedures for research and training, a Delphi analysis was performed to reach consensus on the practice of the laparoscopic gastric bypass and sleeve gastrectomy in the Netherlands. After a pre-round identifying all possible steps from literature and expert opinion within our study group, questionnaires were send to 68 registered Dutch bariatric surgeons, with 73 steps for bypass surgery and 51 steps for sleeve gastrectomy. Statistical analysis was performed to identify steps with and without consensus. This process was repeated to reach consensus of all necessary steps. Thirty-eight participants (56%) responded in the first round and 32 participants (47%) in the second round. After the first Delphi round, 19 steps for gastric bypass (26%) and 14 for sleeve gastrectomy (27%) gained full consensus. After the second round, an additional amount of 10 and 12 sub-steps was confirmed as key steps, respectively. Thirteen steps in the gastric bypass and seven in the gastric sleeve were deemed advisable. Our expert panel showed a high level of consensus expressed in a Cronbach's alpha of 0.82 for the gastric bypass and 0.87 for the sleeve gastrectomy. The Delphi consensus defined 29 steps for gastric bypass and 26 for sleeve gastrectomy as being crucial for correct performance of these procedures to the standards of our expert panel. These results offer a clear framework for the technical execution of these procedures.

  10. Prototype pushing robot for emplacing vitrified waste canisters into horizontal disposal drifts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Londe, L.; Seidler, W.K.; Bosgiraud, J.M.

    2007-07-01

    Within the French Underground Disposal concept, as described in ANDRA's (Agence Nationale pour la Gestion des Dechets Radioactifs) Dossier 2005, the Pushing Robot is an application envisaged for the emplacement (and the potential retrieval) of 'Vitrified waste packages', also called 'C type packages'. ANDRA has developed a Prototype Pushing Robot within the framework of the ESDRED Project (Engineering Studies and Demonstration of Repository Design) which is co-funded by the European Commission as part of the sixth EURATOM Research and Training Framework Programme (FP6) on nuclear energy (2002 - 2006). The Rationale of the Pushing Robot technology comes from various considerations,more » including the need for (1) a simple and robust system, capable of moving (and potentially retrieving) on up to 40 metres (m), a 2 tonne C type package (mounted on ceramic sliding runners) inside the carbon steel sleeve constituting the liner (and rock support) of a horizontal disposal cell, (2) small annular clearances between the package and the liner, (3) compactness of the device to be transferred from surface to underground, jointly with the package, inside a shielding cask, and (4) remote controlled operations for the sake of radioprotection. The initial design, based on gripping supports, has been replaced by a 'technical variant' based on inflatable toric jacks. It was then possible, using a test bench, to check that the Pushing Robot worked properly. Steps as high as 7 mm were successfully cleared by a dummy package pushed by the Prototype.. Based on the lessons learned by ANDRA's regarding the Prototype Pushing Robot, a new Scope of Work is being written for the Contract concerning an Industrial Scale Demonstrator. The Industrial Scale Demonstration should be completed by the end of the second Quarter of 2008. (authors)« less

  11. Does Sleeve Shape Make a Difference in Outcomes?

    PubMed

    Alhaj Saleh, Adel; Janik, Michal R; Mustafa, Rami R; Alshehri, Mohammed; Khan, Adil H; Kalantar Motamedi, Seyed Mohammad; Rahim, Shiraz; Patel, Indravadan; Aryaie, Amir; Abbas, Mujjahid; Rogula, Tomasz; Khaitan, Leena

    2018-06-01

    Sleeve gastrectomy (SG) is one of the most common procedures performed for weight loss. Many seek the "perfect sleeve" with the notion that the type of calibrating device affects sleeve shape, and this in turn will affect outcomes and complications. Two major concerns after SG are amount of weight loss and acid reflux. Our aim was to determine if the various calibration methods could impact sleeve shape and thereby allow for better outcomes of weight loss and reflux. A retrospective chart review was performed of 210 patients who underwent SG and had postoperative upper gastrointestinal (UGI) study from 2011 to 2015 in a single center by a single (fellowship-trained) bariatric surgeon. Data regarding demographics, calibrating devices and clinical outcomes at 1 year (weight loss and de novo acid reflux) were collected. UGIs were reviewed by two radiologists blinded to the clinical outcomes. Sleeve shape was classified according to a previously described classification as tubular, dumbbell, upper pouch, or lower pouch. The types of calibrating devices used to guide the sleeve size intraoperatively were endoscopy, large-bore orogastric tube, and fenestrated suction tube. One hundred ninety-nine patients met inclusion criteria (11 had no esophagram). Demographics revealed age 45.76 ± 10.6 years, BMI 47 ± 8.6 kg/m 2 , and 82% female. Calibration devices used were endoscopic guidance (7.6%), large bore orogastric tube (41.4%), and fenestrated suction tube (50.5%). Sleeve shape was reported as 32.6% tubular, 20.6% dumbbell, 39.2% lower pouch, and 7.5% upper pouch (100% interrater reliability). No correlation was seen with type of calibration used. Of patients, 62.0% had > 50% excess weight loss at 1 year. Twenty-three percent of patients remained on PPI at 1 year (of which 43.3% did not have reflux preoperatively). The lower pouch shape showed a trend toward less reflux and more weight loss. This study showed no clear association between uniformity of sleeve shape and the type of calibration device used. The study showed a trend toward decreased reflux and improved weight loss with the lower pouch shape, regardless of calibration device.

  12. Characterization and Surgical Management of Achilles Tendon Sleeve Avulsions.

    PubMed

    Huh, Jeannie; Easley, Mark E; Nunley, James A

    2016-06-01

    An Achilles sleeve avulsion occurs when the tendon ruptures distally from its calcaneal insertion as a continuous "sleeve." This relatively rare injury pattern may not be appreciated until the time of surgery and can be challenging to treat because, unlike a midsubstance rupture, insufficient tendon remains on the calcaneus to allow for end-to-end repair, and unlike a tuberosity avulsion fracture, any bony element avulsed with the tendon is inadequate for internal fixation. This study aimed to highlight the characteristics of Achilles sleeve avulsions and present the outcomes of operative repair using suture anchor fixation. A retrospective analysis was conducted on 11 consecutive Achilles tendon sleeve avulsions (10 males, 1 female; mean age 44 years) that underwent operative repair between 2008 and 2014. Patient demographics, injury presentation, and operative details were reviewed. Postoperative outcomes were collected at a mean follow-up of 38.4 (range, 12-83.5) months, including the American Orthopaedic Foot & Ankle Society (AOFAS) Ankle-Hindfoot score, visual analog scale (VAS) for pain, plantarflexion strength, patient satisfaction, and complications. Eight patients (72.7%) had preexisting symptoms of insertional Achilles disease. Ten of 11 (90.9%) injuries were sustained during recreational athletic activity. An Achilles sleeve avulsion was recognized preoperatively in 7 of 11 (64%) cases, where lateral ankle radiographs demonstrated a small radiodensity several centimeters proximal to the calcaneal insertion. Intraoperatively, 90.9% of sleeve avulsions had a concomitant Haglund deformity and macroscopic evidence of insertional tendinopathy. All patients healed after suture anchor repair. The average AOFAS score was 92.8 and VAS score was 0.9. Ten patients (90.9%) were completely satisfied. One complication occurred, consisting of delayed wound healing. Achilles tendon sleeve avulsions predominantly occurred in middle-aged men with preexisting insertional disease, while engaged in athletic activity. Suture anchor fixation, combined with addressing concomitant insertional pathology, was a reliable and safe technique for the operative management of Achilles tendon sleeve avulsions. The majority of patients returned to their preinjury levels of work and recreational activity. Level IV, retrospective case series. © The Author(s) 2016.

  13. Negative pressures during swing phase in below-knee prostheses with rubber sleeve suspension.

    PubMed

    Chino, N; Pearson, J R; Cockrell, J L; Mikishko, H A; Koepke, G H

    1975-01-01

    Negative pressures in the small space between the distal stump and the below-knee prosthetic socket were measured during swing phase for a series of nine subjects. A molded rubber sleeve connecting the prosthesis and the thigh was found to enhance this effect so that suction suspension occurred during the entire swing phase. Deterioration of the suction occurred when the sleeve was intentionally pierced, and when other suspensions such as a suprapatellar cuff or thigh band were tested. The findings indicate that the total-contact socket, gel liner and elastic sleeve combine to create suction in the below-knee socket which improves overall comfort and function for the patient in using the prosthesis.

  14. Novel technique for relieving anastomotic tension using halo-vest immobilization after tracheal sleeve resection.

    PubMed

    Imai, Kazuhiro; Minamiya, Yoshihiro; Saito, Hajime; Miyakoshi, Naohisa; Hongo, Michio; Kasukawa, Yuji; Ishikawa, Yoshinori; Motoyama, Satoru; Sato, Yusuke; Shimada, Yoichi; Ogawa, Jun-ichi

    2013-07-01

    We describe a novel technique of using halo-vest-enforced immobilization to relieve anastomotic tension after tracheal sleeve resection. Immediately after the tracheal sleeve resection, four halo titanium pins were inserted in the skulls of the patients to secure the halo-vest. All patients fitted with halo-vests were able to eat and drink and their clinical course was good. Bronchoscopy confirmed the absence of anastomotic leaks and stenoses, and there were no complications associated with the halo-vest. We believe that ensuring neck flexion using a halo-vest after tracheal sleeve resection is an excellent way of relieving anastomotic tension that would predispose the wound to dehiscence.

  15. The ICT monitoring system of the ASTRI SST-2M prototype proposed for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Gianotti, F.; Bruno, P.; Tacchini, A.; Conforti, V.; Fioretti, V.; Tanci, C.; Grillo, A.; Leto, G.; Malaguti, G.; Trifoglio, M.

    2016-08-01

    In the framework of the international Cherenkov Telescope Array (CTA) observatory, the Italian National Institute for Astrophysics (INAF) has developed a dual mirror, small sized, telescope prototype (ASTRI SST-2M), installed in Italy at the INAF observing station located at Serra La Nave, Mt. Etna. The ASTRI SST-2M prototype is the basis of the ASTRI telescopes that will form the mini-array proposed to be installed at the CTA southern site during its preproduction phase. This contribution presents the solutions implemented to realize the monitoring system for the Information and Communication Technology (ICT) infrastructure of the ASTRI SST-2M prototype. The ASTRI ICT monitoring system has been implemented by integrating traditional tools used in computer centers, with specific custom tools which interface via Open Platform Communication Unified Architecture (OPC UA) to the Alma Common Software (ACS) that is used to operate the ASTRI SST-2M prototype. The traditional monitoring tools are based on Simple Network Management Protocol (SNMP) and commercial solutions and features embedded in the devices themselves. They generate alerts by email and SMS. The specific custom tools convert the SNMP protocol into the OPC UA protocol and implement an OPC UA server. The server interacts with an OPC UA client implemented in an ACS component that, through the ACS Notification Channel, sends monitor data and alerts to the central console of the ASTRI SST-2M prototype. The same approach has been proposed also for the monitoring of the CTA onsite ICT infrastructures.

  16. U. S. National Transportation Safety Board (NTSB) reports, recommendations, and responses availability. [Evaluation of fillet-welded reinforcement sleeves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-10-09

    Following the ignition of crude oil that leaked from a fractured 22 in. oil pipeline at a levee crossing at Berwick, Louisiana, on 1/2/80, NTSB has recommended that Texaco Pipeline Co., the line owner, review the practice of using fillet-welded reinforcement sleeves for tie-in welds to determine if these sleeves have caused any pipeline failures in its system; notify the pipeline patrol of the location of such existing sleeves and instruct it to examine the areas around these sleeves for signs of leakage; and evaluate existing procdures for leak detection to make these procedures more effective. The American Petroleum Institutemore » has also been urged to notify its member companies of the Berwick accident and the aforementioned recommendations. These pipeline and other safety recommendation letters and reports of accidents, including the determination of the cause of the explosion, burning, and sinking of the Liberian tanker Seatige.« less

  17. Effect of Viscosity on Fuel Leakage Between Lapped Plungers and Sleeves and on the Discharge from a Pump-Injection System

    NASA Technical Reports Server (NTRS)

    Rothrock, A M; Marsh, E T

    1935-01-01

    Test data and analysis show that the rate of fuel leakage between a lapped plunger and sleeve varies directly with the density of the fuel, the diameter of the plunger, the pressure producing the leakage, and the cube of the mean clearance between the plunger and sleeve. The rate varies inversely as the length of the lapped fit and the viscosity of the fuel. With a mean clearance between the plunger and sleeve of 0.0001 inch the leakage amounts to approximately 0.2 percent of the fuel injected with gasoline and as low as 0.01 percent with diesel fuel oils. With this mean clearance an effective seal is obtained when the length of the lap is three times the diameter of the lap. The deformation of the sleeve and plunger under pressure is sufficient to change the rate of leakage appreciably from that which would be obtained if the clearance was constant under pressure.

  18. Retractor Tool for Brain Surgery

    NASA Technical Reports Server (NTRS)

    Helms, R.; Hayes, T.

    1982-01-01

    Proposed brain-surgery tool has an octogonal fixture for positioning latex tube over incision. Eight stainless-steel wires embedded in latex extend to hold positioning fixture. Another eight are also embedded in the latex. Concentric sleeves are successively inserted into expandable latex tube. The first sleeve is placed over a solid rod. Last sleeve is a stainless-steel tube 1 inch in diameter. It is overcoated with Teflon (or equivalent) material.

  19. Sleeve fracture of the adult patella: Case report and review of the literature.

    PubMed

    Xie, Linjun; Xu, Hong; Zhang, Lizhi; Xu, Rong; Guo, Yingkun

    2017-08-01

    The patellar fractures are common in adults, but rare in children. As a particular type of patellar fracture, however, sleeve fractures are almost always limited to children in the under 16's group. Herein, we report a rare case of a 19-year-old healthy adult female who presented sleeve fracture at the superior pole of the left patella. The clinical and radiological features are found including joint effusion, anterior tilt of the patella and a shell of bone lying proximally to the patella. Computed tomography and magnetic resonance imaging examination have been performed to further confirm the diagnosis of sleeve fracture, rupture of the quadriceps tendon and the cartilaginous injury. Under general anaesthesia, she underwent open surgical procedures for reconstituting anatomically the fracture and repairing the rupture of the quadriceps tendon. Six months after the operation, she could fully use her left knee without any pain and disability. Sleeve fractures of the patellar in adults are extremely rare, and our case is of interest for the first time occurring in healthy female adults. Our case report and literature review was aim to describe the clinic and imaging characteristics of superior pole sleeve fractures in adults, and highlight that physicians must be aware of this entity in adults so as to reduce misdiagnosis due to unfamiliarity.

  20. Crimped braided sleeves for soft, actuating arm in robotic abdominal surgery.

    PubMed

    Elsayed, Yahya; Lekakou, Constantina; Ranzani, Tommaso; Cianchetti, Matteo; Morino, Mario; Arezzo, Alberto; Menciassi, Arianna; Geng, Tao; Saaj, Chakravarthini M

    2015-01-01

    This paper investigates different types of crimped, braided sleeve used for a soft arm for robotic abdominal surgery, with the sleeve required to contain balloon expansion in the pneumatically actuating arm while it follows the required bending, elongation and diameter reduction of the arm. Three types of crimped, braided sleeves from PET (BraidPET) or nylon (BraidGreyNylon and BraidNylon, with different monofilament diameters) were fabricated and tested including geometrical and microstructural characterisation of the crimp and braid, mechanical tests and medical scratching tests for organ damage of domestic pigs. BraidPET caused some organ damage, sliding under normal force of 2-5 N; this was attributed to the high roughness of the braid pattern, the higher friction coefficient of polyethylene terephthalate (PET) compared to nylon, and the high frequency of the crimp peaks for this sleeve. No organ damage was observed for the BraidNylon, attributed to both the lower roughness of the braid pattern and the low friction coefficient of nylon. BraidNylon also required the lowest tensile force during its elongation to similar maximum strain as that of BraidPET, translating to low power requirements. BraidNylon is recommended for the crimped sleeve of the arm designed for robotic abdominal surgery.

  1. Analgesic Effect of Intraperitoneal Bupivacaine Hydrochloride After Laparoscopic Sleeve Gastrectomy: a Randomized Clinical Trial.

    PubMed

    Alamdari, Nasser Malekpour; Bakhtiyari, Mahmood; Gholizadeh, Barmak; Shariati, Catrine

    2018-03-01

    The indications for sleeve gastrectomy as a primary procedure for the surgical treatment of morbid obesity have increased worldwide. Pain is the most common complaint for patients on the first day after laparoscopic sleeve gastrectomy. There are various methods for decreasing pain after laparoscopic sleeve gastrectomy such as the use of intraperitoneal bupivacaine hydrochloride. This clinical trial was an attempt to discover the effects of intraperitoneal bupivacaine hydrochloride on alleviating postoperative pain after laparoscopic sleeve gastrectomy. In general, 120 patients meeting the inclusion criteria were enrolled. Patients were randomly allocated into two interventions and control groups using a balanced block randomization technique. One group received intraperitoneal bupivacaine hydrochloride (30 cm 3 ), and the other group served as the control one and did not receive bupivacaine hydrochloride. Diclofenac suppository and paracetamol injection were administered to both groups for postoperative pain management. The mean subjective postoperative pain score was significantly decreased in patients who received intraperitoneal bupivacaine hydrochloride within the first 24 h after the surgery; thus, the instillation of bupivacaine hydrochloride was beneficial in managing postoperative pain. The intraoperative peritoneal irrigation of bupivacaine hydrochloride (30 cm 3 , 0.25%) in sleeve gastrectomy patients was safe and effective in reducing postoperative pain, nausea, and vomiting (IRCT2016120329181N4).

  2. Aortic Root Biomechanics After Sleeve and David Sparing Techniques: A Finite Element Analysis.

    PubMed

    Tasca, Giordano; Selmi, Matteo; Votta, Emiliano; Redaelli, Paola; Sturla, Francesco; Redaelli, Alberto; Gamba, Amando

    2017-05-01

    Aortic root aneurysm can be treated with valve-sparing procedures. The David and Yacoub techniques have shown excellent long-term results but are technically demanding. Recently, a new and simpler procedure, the Sleeve technique, was proposed with encouraging results. We aimed to quantify the biomechanics of the initially aneurysmal aortic root (AR) after the Sleeve procedure to assess whether it induces abnormal stresses, potentially undermining its durability. Two finite element (FE) models of the physiologic and aneurysmal AR were built, accounting for the anatomical asymmetry and the nonlinear and anisotropic mechanical properties of human AR tissues. On the aneurysmal model, the Sleeve and David techniques were simulated based on the corresponding published technical features. Aortic root biomechanics throughout 2 consecutive cardiac cycles were computed in each simulated configuration. Both sparing techniques restored physiologic-like kinematics of aortic valve (AV) leaflets but induced different leaflets stresses. The time course averaged over the leaflets' bellies was 35% higher in the David model than in the Sleeve model. Commissural stresses, which were equal to 153 and 318 kPa in the physiologic and aneurysmal models, respectively, became 369 and 208 kPa in the David and Sleeve models, respectively. No intrinsic structural problems were detected in the Sleeve model that might jeopardize the durability of the procedure. If corroborated by long-term clinical outcomes, the results obtained suggest that using this new technique could successfully simplify the surgical repair of AR aneurysms and reduce intraoperative complications. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Microwave ablation of ex vivo bovine tissues using a dual slot antenna with a floating metallic sleeve.

    PubMed

    Ibitoye, Ayo Zaccheaus; Nwoye, Ephraim Okeke; Aweda, Adebayo Moses; Oremosu, Ademola A; Anunobi, Chidozie Charles; Akanmu, Nurudeen Olanrewaju

    2016-12-01

    To study the efficiency of a dual slot antenna with a floating metallic sleeve on the ablation of different ex vivo bovine tissues. COMSOL Multiphysics® version 4.4 (Stockholm, Sweden), which is based on finite element methods (FEM), was used to design and simulate monopole and dual slot with sleeve antennas. Power, specific absorption rate (SAR), temperature and necrosis distributions in the selected tissues were determined using these antennas. Monopole and dual slot with sleeve antennas were designed, simulated, constructed and applied in this study based on a semi-rigid coaxial cable. Ex vivo experiments were performed on liver, lung, muscle and heart of bovine obtained from a public animal slaughter house. The microwave energy was delivered using a 2.45 GHz solid-state microwave generator at 40 W for 3, 5 and 10 min. Aspect ratio, ablation length and ablation diameter were also determined on ablated tissues and compared with simulated results. Student's t-test was used to compare the statistically significant difference between the performance of the two antennas. The dual slot antenna with sleeve produces localised microwave energy better than the monopole antenna in all ablated tissues using simulation and experimental validation methods. There were significant differences in ablation diameter and aspect ratio between the sleeve antenna and monopole antenna. Additionally, there were no significant differences between the simulation and experimental results. This study demonstrated that the dual slot antenna with sleeve produced larger ablation zones and higher sphericity index in ex vivo bovine tissues with minimal backward heating when compared with the monopole antenna.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pallesen, T.R.; Braestrup, M.W.; Jorgensen, O.

    Development of Danish North Sea hydrocarbon resources includes the 17-km Rolf pipeline installed in 1985. This one consists of an insulated 8-in. two-phase flow product line with a 3-in. piggyback gas lift line. A practical solution to design of this insulated pipeline, including the small diameter, piggyback injection line was corrosion coating of fusion bonded epoxy (FBE) and polyethylene (PE) sleeve pipe. The insulation design prevents hydrate formation under the most conservative flow regime during gas lift production. Also, the required minimum flow rate during the initial natural lift period is well below the value anticipiated at the initiation ofmore » gas lift. The weight coating design ensures stability on the seabed during the summer months only; thus trenching was required during the same installation season. Installation of insulated flowlines serving marginal fields is a significant feature of North Sea hydrocarbon development projects. The Skjold field is connected to Gorm by a 6-in., two-phase-flow line. The 11-km line was installed in 1982 as the first insulated pipeline in the North Sea. The Rolf field, located 17 km west of Gorm, went on stream Jan. 2. The development includes an unmanned wellhead platform and an insulated, two-phase-flow pipeline to the Gorm E riser platform. After separation on the Gorm C process platform, the oil and condensate are transported to shore through the 20-in. oil pipeline, and the natural gas is piped to Tyra for transmission through the 30-in. gas pipeline. Oil production at Rolf is assisted by the injection of lift gas, transported from Gorm through a 3-in. pipeline, installed piggyback on the insulated 8-in. product line. The seabed is smooth and sandy, the water depth varying between 33.7 m (110.5 ft) at Rolf and 39.1 m (128 ft) at Gorm.« less

  5. Sleeve gastrectomy and the risk of leak: a systematic analysis of 4,888 patients.

    PubMed

    Aurora, Alexander R; Khaitan, Leena; Saber, Alan A

    2012-06-01

    Sleeve gastrectomy has become a popular stand-alone bariatric procedure with comparable weight loss and resolution of comorbidities to that of laparoscopic gastric bypass. The simplicity of the procedure and the decreased long-term risk profile make this surgery more appealing. Nonetheless, the ever present risk of a staple-line leak is still of great concern and needs further investigation. An electronic literature search of MEDLINE database plus manual reference checks of articles published on laparoscopic sleeve gastrectomy for morbid obesity and its complications was completed. Keywords used in the search were "sleeve gastrectomy" OR "gastric sleeve" AND "leak." We analyzed 29 publications, including 4,888 patients. We analyzed the frequency of leak after sleeve gastrectomy and its associated risks of causation. The risk of leak after sleeve gastrectomy in all comers was 2.4%. This risk was 2.9% in the super-obese [body mass index (BMI) > 50 kg/m(2)] and 2.2% for BMI < 50 kg/m(2). Staple height and use of buttressing material did not affect leak rate. The use of a size 40-Fr or greater bougie was associated with a leak rate of 0.6% compared with those who used smaller sizes whose leak rate was 2.8%. Leaks were found at the proximal third of the stomach in 89% of cases. Most leaks were diagnosed after discharge. Endoscopic management is a viable option for leaks and was documented in 11% of cases as successful. Sleeve gastrectomy has become an important surgical option for the treatment of the ever growing morbidly obese population. The risk of leak is low at 2.4%. Attention to detail specifically at the esophagogastric junction cannot be stressed enough. Careful patient selection (BMI < 50 kg/m(2)) and adopting the use of a 40-Fr or larger bougie may decrease the risk of leak. Vigilant follow-up during the first 30 days is critical to avoid catastrophe, because most leaks will happen after patient discharge.

  6. Gastroesophageal reflux disease and morbid obesity: To sleeve or not to sleeve?

    PubMed Central

    Rebecchi, Fabrizio; Allaix, Marco E; Patti, Marco G; Schlottmann, Francisco; Morino, Mario

    2017-01-01

    Laparoscopic sleeve gastrectomy (LSG) has reached wide popularity during the last 15 years, due to the limited morbidity and mortality rates, and the very good weight loss results and effects on comorbid conditions. However, there are concerns regarding the effects of LSG on gastroesophageal reflux disease (GERD). The interpretation of the current evidence is challenged by the fact that the LSG technique is not standardized, and most studies investigate the presence of GERD by assessing symptoms and the use of acid reducing medications only. A few studies objectively investigated gastroesophageal function and the reflux profile by esophageal manometry and 24-h pH monitoring, reporting postoperative normalization of esophageal acid exposure in up to 85% of patients with preoperative GERD, and occurrence of de novo GERD in about 5% of cases. There is increasing evidence showing the key role of the surgical technique on the incidence of postoperative GERD. Main technical issues are a relative narrowing of the mid portion of the gastric sleeve, a redundant upper part of the sleeve (both depending on the angle under which the sleeve is stapled), and the presence of a hiatal hernia. Concomitant hiatal hernia repair is recommended. To date, either medical therapy with proton pump inhibitors or conversion of LSG to laparoscopic Roux-en-Y gastric bypass are the available options for the management of GERD after LSG. Recently, new minimally invasive approaches have been proposed in patients with GERD and hypotensive LES: the LINX® Reflux Management System procedure and the Stretta® procedure. Large studies are needed to assess the safety and long-term efficacy of these new approaches. In conclusion, the recent publication of pH monitoring data and the new insights in the association between sleeve morphology and GERD control have led to a wider acceptance of LSG as bariatric procedure also in obese patients with GERD, as recently stated in the 5th International Consensus Conference on sleeve gastrectomy. PMID:28428706

  7. Gastroesophageal reflux disease and morbid obesity: To sleeve or not to sleeve?

    PubMed

    Rebecchi, Fabrizio; Allaix, Marco E; Patti, Marco G; Schlottmann, Francisco; Morino, Mario

    2017-04-07

    Laparoscopic sleeve gastrectomy (LSG) has reached wide popularity during the last 15 years, due to the limited morbidity and mortality rates, and the very good weight loss results and effects on comorbid conditions. However, there are concerns regarding the effects of LSG on gastroesophageal reflux disease (GERD). The interpretation of the current evidence is challenged by the fact that the LSG technique is not standardized, and most studies investigate the presence of GERD by assessing symptoms and the use of acid reducing medications only. A few studies objectively investigated gastroesophageal function and the reflux profile by esophageal manometry and 24-h pH monitoring, reporting postoperative normalization of esophageal acid exposure in up to 85% of patients with preoperative GERD, and occurrence of de novo GERD in about 5% of cases. There is increasing evidence showing the key role of the surgical technique on the incidence of postoperative GERD. Main technical issues are a relative narrowing of the mid portion of the gastric sleeve, a redundant upper part of the sleeve (both depending on the angle under which the sleeve is stapled), and the presence of a hiatal hernia. Concomitant hiatal hernia repair is recommended. To date, either medical therapy with proton pump inhibitors or conversion of LSG to laparoscopic Roux-en-Y gastric bypass are the available options for the management of GERD after LSG. Recently, new minimally invasive approaches have been proposed in patients with GERD and hypotensive LES: the LINX ® Reflux Management System procedure and the Stretta ® procedure. Large studies are needed to assess the safety and long-term efficacy of these new approaches. In conclusion, the recent publication of pH monitoring data and the new insights in the association between sleeve morphology and GERD control have led to a wider acceptance of LSG as bariatric procedure also in obese patients with GERD, as recently stated in the 5 th International Consensus Conference on sleeve gastrectomy.

  8. Analysis of the harmonics and power-factor effects at a utility-inertied photovoltaic system

    NASA Astrophysics Data System (ADS)

    Campen, G. L.

    The harmonics and power factor characteristics and effects of a single residential photovoltaic (PV) installation using a line commutated inverter are outlined. The data were taken during a 5 day measurement program at a prototype residential PV installation in Arizona. The magnitude and phase of various currents and voltages from the fundamental to the 13th harmonic were recorded both with and without the operation of the PV system. A candidate method of modeling the installation for computer studies of larger concentrations is given.

  9. Solar heating and cooling system design and development

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The progress made in the manufacture, test, evaluation, installation, problem resolution, performance evaluation, and development of eight prototype solar heating and combined heating and cooling systems is described.

  10. National preceptor development program (PDP) prototype. The third of a 3-part series.

    PubMed

    Cox, Craig D; Mulherin, Katrina; Walter, Sheila

    2018-03-01

    Preceptor development is critical to successful delivery of experiential learning. Although many preceptor development programs exist, a more individualized approach to training is needed. To accomplish this a national preceptor development program should be considered based on the continuing professional development model. A detailed prototype for this program has been described. In this final installment of the series, the twelve evidence-based recommendations from the first installment were utilized to construct a prototype for a preceptor development program. Over a three-month period, investigators experimented with different designs and models before approving the final prototype. The prototype took the form of an electronic learning platform. Several categories were integral to the design and included sections entitled preceptor spotlight, mentorship, global outreach, choose your own adventure, continuing professional development, feedback, virtual online community, highlights/advertisements, what's new, competency assessment, and frequently asked questions. A graphic was developed to depict the process by which a preceptor would navigate through the web-based learning platform. The authors purposefully maintained a creative and unlimited vision for preceptor development. This conceptual model is intended to spark discussion and augment, refine, or develop entirely innovative ideas to meet preceptor needs. Development of a preceptor development platform could foster improved competency performance, enhanced interest in learning, and promote continuing professional development. With a greater focus on experiential education in pharmacy, the need for a national preceptor development resource is only expected to increase. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Technician Marshall MacCready installs solar cells on the Helios Prototype

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Technician Marshall MacCready carefully lays a panel of solar cells into place on a wing section of the Helios Prototype flying wing at AeroVironment's Design Development Center in Simi Valley, California. The bi-facial cells, manufactured by SunPower, Inc., of Sunnyvale, California, are among 64,000 solar cells which have been installed on the solar-powered aircraft to provide electricity to its 14 motors and operating systems. Developed by AeroVironment under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) project, the Helios Prototype is the forerunner of a planned fleet of slow-flying, long duration, high-altitude aircraft which can perform atmospheric science missions and serve as telecommunications relay platforms in the stratosphere. Target goals set by NASA for the giant 246-foot span flying wing include reaching and sustaining subsonic horizontal flight at 100,000 feet altitude in 2001, and sustained continuous flight for at least four days and nights above 50,000 feet altitude 2003 with the aid of a regenerative fuel cell-based energy storage system now being developed.

  12. Application of caterpillar SMSF on ZiL 645 engine. Volume 2. Appendices. Export trade information

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-11-23

    The report, written by the Southwest Research Institute and Caterpillar, Inc., was funded by the U.S. Trade and Development Agency on behalf of ZiL, a major Russian truck manufacturer. The purpose of the study was as follows: Install the Sleeve Metering Fuel System (SMFS) on the ZIL 645 NA. This would also include conversion of the MAN combustion system to a torroidal combustion system. Evaluate the cylinder head and determine if modifications are necessary. Design and test several sets of nozzles and two pistons to determine effect on smoke and fuel consumption. Obtain steady state emissions with the 'best' configurationmore » determined by smoke and specific fuel consumption and compare the results with EURO 1 standards.« less

  13. Poly(D,L-Lactide-Co-Glycolide) Tubes With Multifilament Chitosan Yarn or Chitosan Sponge Core in Nerve Regeneration.

    PubMed

    Wlaszczuk, Adam; Marcol, Wiesław; Kucharska, Magdalena; Wawro, Dariusz; Palen, Piotr; Lewin-Kowalik, Joanna

    2016-11-01

    The influence of different kinds of nerve guidance conduits on regeneration of totally transected rat sciatic nerves through a 7-mm gap was examined. Five different types of conduits made of chitosan and poly(D,L-lactide-co-glycolide) (PLGA) were constructed and tested in vivo. We divided 50 animals into equal groups of 10, with a different type of conduit implanted in each group: chitosan sponge core with an average molecular mass of polymer (Mv) of 287 kDa with 7 channels in a PLGA sleeve, chitosan sponge core with an Mv of 423 kDa with 7 channels in a PLGA sleeve, chitosan sponge core (Mv, 423 kDa) with 13 channels in a PLGA sleeve, chitosan multifilament yarn in a PLGA sleeve, and a PLGA sleeve only. Seven weeks after the operation, we examined the distance covered by regenerating nerve fibers, growing of nerves into the conduit's core, and intensity and type of inflammatory reaction in the conduit, as well as autotomy behavior (reflecting neuropathic pain intensity) in the animals. Two types of conduits were allowing nerve outgrowth through the gap with minor autotomy and minor inflammatory reactions. These were the conduits with chitosan multifilament yarn in a PLGA sleeve and the conduits with 13-channel microcrystalline chitosan sponge in a PLGA sleeve. The type of chitosan used to build the nerve guidance conduit influences the intensity and character of inflammatory reaction present during nerve regeneration, which in turn affects the distance crossed by regenerating nerve fibers, growing of the nerve fibers into the conduit's core, and the intensity of autotomy in the animals. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Sleeve fracture of the adult patella

    PubMed Central

    Xie, Linjun; Xu, Hong; Zhang, Lizhi; Xu, Rong; Guo, Yingkun

    2017-01-01

    Abstract Rationale: The patellar fractures are common in adults, but rare in children. As a particular type of patellar fracture, however, sleeve fractures are almost always limited to children in the under 16's group. Patient concerns: Herein, we report a rare case of a 19-year-old healthy adult female who presented sleeve fracture at the superior pole of the left patella. The clinical and radiological features are found including joint effusion, anterior tilt of the patella and a shell of bone lying proximally to the patella. Diagnoses: Computed tomography and magnetic resonance imaging examination have been performed to further confirm the diagnosis of sleeve fracture, rupture of the quadriceps tendon and the cartilaginous injury. Interventions: Under general anaesthesia, she underwent open surgical procedures for reconstituting anatomically the fracture and repairing the rupture of the quadriceps tendon. Outcomes: Six months after the operation, she could fully use her left knee without any pain and disability. Lessons: Sleeve fractures of the patellar in adults are extremely rare, and our case is of interest for the first time occurring in healthy female adults. Our case report and literature review was aim to describe the clinic and imaging characteristics of superior pole sleeve fractures in adults, and highlight that physicians must be aware of this entity in adults so as to reduce misdiagnosis due to unfamiliarity. PMID:28796028

  15. Hemodynamic effect and safety of intermittent sequential pneumatic compression leg sleeves in patients with congestive heart failure.

    PubMed

    Bickel, Amitai; Shturman, Alexander; Sergeiev, Michael; Ivry, Shimon; Eitan, Arieh; Atar, Shaul

    2014-10-01

    Pneumatic leg sleeves are widely used after prolonged operations for prevention of venous stasis. In healthy volunteers they increase cardiac function. We evaluated the hemodynamic effects and safety of intermittent sequential pneumatic compression (ISPC) leg sleeves in patients with chronic congestive heart failure (CHF). We studied 19 patients with systolic left ventricular dysfunction and CHF. ISPC leg sleeves, each with 10 air cells, were operated by a computerized compressor, exerting 2 cycles/min. Hemodynamic and echocardiographic parameters were measured before, during, and after ISPC activation. The baseline mean left ventricular ejection fraction was 29 ± 9.2%, median 32%, range 10%-40%. Cardiac output (from 4.26 to 4.83 L/min; P = .008) and stroke volume (from 56.1 to 63.5 mL; P = .029) increased significantly after ISPC activation, without a reciprocal increase in heart rate, and declined after sleeve deactivation. Systemic vascular resistance (SVR) decreased significantly (from 1,520 to 1,216 dyne-s/cm5; P = .0005), and remained lower than the baseline level throughout the study. There was no detrimental effect on diastolic function and no adverse clinical events, despite increased pulmonary venous return. ISPC leg sleeves in patients with chronic CHF do not exacerbate symptoms and transiently improve cardiac output through an increase in stroke volume and a reduction in SVR. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. The design, effectiveness and acceptability of the arm sleeve for the prevention of body fluid contamination during obstetric procedures.

    PubMed

    Kabukoba, J J; Pearce, J M

    1993-08-01

    1. To design a device that would reduce contamination of staff during obstetric procedures. 2. To undertake clinical trials to assess the effectiveness and acceptability of such a device. A prospective study. The arm sleeve is made of a nonwoven material laminated on polyethylene film making it waterproof. It has an elastomeric cuff with adhesive that ensures a watertight seal between it and the glove. Delivery suite in a teaching hospital. Doctors and midwives were requested to wear the sleeve on top of the standard gown and gloves. Each user was assessed for blood contamination at the end of the procedure and a questionnaire detailing the extent of contamination and the views of the user was completed. Eighty questionnaires were completed. The contamination of arms and hands was 3.8% and 5%, respectively. Eighty-nine percent thought the sleeve had served its purpose and 76% said they would use it regularly. The sleeve is an effective protective device which complements the glove and gown. We recommend that it should be used during all obstetric procedures.

  17. Airborne asbestos exposures associated with work on asbestos fire sleeve materials.

    PubMed

    Blake, Charles L; Harbison, Stephen C; Johnson, Giffe T; Harbison, Raymond D

    2011-11-01

    Asbestos-containing fire sleeves have been used as a fire protection measure for aircraft fluid hoses. This investigation was conducted to determine the level of airborne asbestos fiber exposure experienced by mechanics who work with fire sleeve protected hoses. Duplicate testing was performed inside a small, enclosed workroom during the fabrication of hose assemblies. Personal air samples taken during this work showed detectable, but low airborne asbestos fiber exposures. Analysis of personal samples (n=9) using phrase contract microscopy (PCM) indicated task duration airborne fiber concentrations ranging from 0.017 to 0.063 fibers per milliliter (f/ml) for sampling durations of 167-198 min, and 0.022-0.14 f/ml for 30 min samples. Airborne chrysotile fibers were detected for four of these nine personal samples, and the resulting asbestos adjusted airborne fiber concentrations ranged from 0.014 to 0.025 f/ml. These results indicate that work with asbestos fire sleeve and fire sleeve protected hose assemblies, does not produce regulatory noncompliant levels of asbestos exposure for persons who handle, cut and fit these asbestos-containing materials. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Prototype space erectable radiator system ground test article development

    NASA Technical Reports Server (NTRS)

    Alario, Joseph P.

    1988-01-01

    A prototype heat rejecting system is being developed by NASA-JSC for possible space station applications. This modular system, the Space-Erectable Radiator System Ground Test Article (SERS-GTA) with high-capacity radiator panels, can be installed and replaced on-orbit. The design, fabrication and testing of a representative ground test article are discussed. Acceptance test data for the heat pipe radiator panel and the whiffletree clamping mechanism have been presented.

  19. Jam proof closure assembly for lidded pressure vessels

    DOEpatents

    Cioletti, Olisse C.

    1992-01-01

    An expendable closure assembly is provided for use (in multiple units) with a lockable pressure vessel cover along its rim, such as of an autoclave. This assembly is suited to variable compressive contact and locking with the vessel lid sealing gasket. The closure assembly consists of a thick walled sleeve insert for retention in the under bores fabricated in the cover periphery and the sleeve is provided with internal threading only. A snap serves as a retainer on the underside of the sleeve, locking it into an under bore retention channel. Finally, a standard elongate externally threaded bolt is sized for mating cooperation with the so positioned sleeve, whereby the location of the bolt shaft in the cover bore hole determines its compressive contact on the underlying gasket.

  20. Prototype solar-heated hot water systems and double-walled heat exchangers

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Development progress made on two solar-heated hot water systems and two heat exchangers is reported. The development, manufacture, installation, maintenance, problem resolution, and system evaluation are described.

  1. Non-contact wearable single forearm cardiac biopotential acquisition device

    NASA Astrophysics Data System (ADS)

    Gonçalves, Sérgio; Carneiro Martins, Raul

    2013-09-01

    In this work the authors propose a novel approach to obtain the electrocardiogram in the forearm using non-contact sensing. This new solution should be at same time portable, ergonomic and robust, enabling its use in different set of applications. A system of four electrodes was used in an adjustable sleeve to be wrapped in the forearm. No additional electrode references were used in other body parts. In order to increase the sensitivity of the system, an harmonium like approach was used in the design of the electrodes. The prototype was then compared with a similar system with a flat conformation. The developed prototype enabled the acquisition of an ECG signal in the forearm and the inclusion of the harmonium like electrode conformation resulted in a considerable increase of the sensitivity of the system. The acquired signal did not enable the identification of all characteristic cardiac waves. However, it was possible to identify clearly a signal pattern, characteristic of the QRS complex. The properties of the acquired signal restrict their use in rigorous electrocardiographic studies, allowing, however, its application in heart rate variability monitoring and biometric identification without the disadvantages usually associated with conventional electrodes. This makes it specially useful for man-machine interfaces and automated identification.

  2. Core-Cutoff Tool

    NASA Technical Reports Server (NTRS)

    Gheen, Darrell

    2007-01-01

    A tool makes a cut perpendicular to the cylindrical axis of a core hole at a predetermined depth to free the core at that depth. The tool does not damage the surrounding material from which the core was cut, and it operates within the core-hole kerf. Coring usually begins with use of a hole saw or a hollow cylindrical abrasive cutting tool to make an annular hole that leaves the core (sometimes called the plug ) in place. In this approach to coring as practiced heretofore, the core is removed forcibly in a manner chosen to shear the core, preferably at or near the greatest depth of the core hole. Unfortunately, such forcible removal often damages both the core and the surrounding material (see Figure 1). In an alternative prior approach, especially applicable to toxic or fragile material, a core is formed and freed by means of milling operations that generate much material waste. In contrast, the present tool eliminates the damage associated with the hole-saw approach and reduces the extent of milling operations (and, hence, reduces the waste) associated with the milling approach. The present tool (see Figure 2) includes an inner sleeve and an outer sleeve and resembles the hollow cylindrical tool used to cut the core hole. The sleeves are thin enough that this tool fits within the kerf of the core hole. The inner sleeve is attached to a shaft that, in turn, can be attached to a drill motor or handle for turning the tool. This tool also includes a cutting wire attached to the distal ends of both sleeves. The cutting wire is long enough that with sufficient relative rotation of the inner and outer sleeves, the wire can cut all the way to the center of the core. The tool is inserted in the kerf until its distal end is seated at the full depth. The inner sleeve is then turned. During turning, frictional drag on the outer core pulls the cutting wire into contact with the core. The cutting force of the wire against the core increases with the tension in the wire and, hence, with the frictional drag acting on the outer sleeve. As the wire cuts toward the center of the core, the inner sleeve rotates farther with respect to the outer sleeve. Once the wire has cut to the center of the core, the tool and the core can be removed from the hole. The proper choice of cutting wire depends on the properties of the core material. For a sufficiently soft core material, a nonmetallic monofilament can be used. For a rubber-like core material, a metal wire can be used. For a harder core material, it is necessary to use an abrasive wire, and the efficiency of the tool can be increased greatly by vacuuming away the particles generated during cutting. For a core material that can readily be melted or otherwise cut by use of heat, it could be preferable to use an electrically heated cutting wire. In such a case, electric current can be supplied to the cutting wire, from an electrically isolated source, via rotating contact rings mounted on the sleeves.

  3. Maritime Analytics Prototype: Final Development Report

    DTIC Science & Technology

    2014-04-01

    access management platform OpenAM , support for multiple instances of the same type of widget and support for installation specific configuration files to...et de la gestion de l’accès OpenAM , le support pour plusieurs instances du même type de widget et le support des fichiers d’installation de...open source authentication and access management platform OpenAM , support for multiple instances of the same type of widget and support for

  4. Steamer II: Steamer prototype component inventory and user interface commands. Technical report, 1988-1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dickieson, J.L.; Thode, W.F.; Newbury, K.

    1988-12-01

    Over the last several years, Navy Personnel Research and Development has produced a prototype simulation of a 1200-psi steam plant. This simulation, called Steamer, is installed on an expensive Symbolics minicomputer at the Surface Warfare Officers School, Pacific Coronado, California. The fundamental research goal of the Steamer prototype system was to evaluate the potential of, what was then, new artificial intelligence (AI) hardware and software technology for supporting the construction of computer-based training systems using graphic representations of complex, dynamic systems. The area of propulsion engineering was chosen for a number of reasons. This document describes the Steamer prototype systemmore » components and user interface commands and establishes a starting point for designing, developing, and implementing Steamer II. Careful examination of the actual program code produced an inventory that describes the hardware, system software, application software, and documentation for the Steamer prototype system. Exercising all menu options systematically produced an inventory of all Steamer prototype user interface commands.« less

  5. Retrospective Comparison of Single-Port Sleeve Gastrectomy Versus Three-Port Laparoscopic Sleeve Gastrectomy: a Propensity Score Adjustment Analysis.

    PubMed

    Mauriello, Claudio; Chouillard, Elie; d'alessandro, Antonio; Marte, Gianpaolo; Papadimitriou, Argyri; Chahine, Elias; Kassir, Radwan

    2018-04-16

    Evaluate the efficacy of single-port sleeve gastrectomy (SPSG) and then compare it to a less-invasive sleeve approach (three-port) (3PSG) according to a propensity score (PS) matching analysis. We analyzed all patients who underwent SG through a three-port or a single-port laparoscopic approach. After 2 years, the follow-up was completed in 84% patients treated with 3PSG and 95% patients of the SPSG group. Excess weight loss (EWL) was comparable for the first year of follow-up within the two groups except for the controls at 3 months in which the SPSG group showed a higher EWL (p = 0.0243). We demonstrated the efficacy of SPSG in bariatric surgery even compared to another, less invasive, laparoscopic SG approach (three-port).

  6. PWR integral tie plate and locking mechanism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flora, B.S.; Osborne, J.L.

    1980-08-26

    A locking mechanism for securing an upper tie plate to the tie rods of a nuclear fuel bundle is described. The mechanism includes an upper tie plate assembly and locking sleeves fixed to the ends of the tie rods. The tie plate is part of the upper tie plate assembly and is secured to the fuel bundle by securing the entire upper tie plate assembly to the locking sleeves fixed to the tie rods. The assembly includes, in addition to the tie plate, locking nuts for engaging the locking sleeves, retaining sleeves to operably connect the locking nuts to themore » assembly, a spring biased reaction plate to restrain the locking nuts in the locked position and a means to facilitate the removal of the entire assembly as a unit from the fuel bundle.« less

  7. The management of amputations of the leg using a new rigid foam plaster for prosthetic fitting.

    PubMed

    Hölter, W; Echterhoff, M; Blömer, A; Verfürden, H

    1980-01-01

    This paper describes the use of a rigid polyurethane foam to construct a stump socket for immediate or early prosthetic fitting in 15 patients with amputation through the leg. The foam plaster is poured into a prepared cotton sleeve, with a zip incorporated, and rolled out to a layer 4 mm thick. The filled sleeve is put around the stump and the zip closed, moulding the sleeve firmly to the stump. The closed sleeve hardens into a rigid polyurethane shell within 20 min. Aferwards the skeletal prosthetic components are fixed with the same rigid foam. The polyurethane foam socket is quickly and cleanly prepared, only one third of the weight of a plaster of Paris cast and is easily removed by means of the zip, allowing access to the stump.

  8. NEUTRONIC REACTORS

    DOEpatents

    Wigner, E.P.; Young, G.J.

    1958-10-14

    A method is presented for loading and unloading rod type fuel elements of a neutronic reactor of the heterogeneous, solld moderator, liquid cooled type. In the embodiment illustrated, the fuel rods are disposed in vertical coolant channels in the reactor core. The fuel rods are loaded and unloaded through the upper openings of the channels which are immersed in the coolant liquid, such as water. Unloading is accomplished by means of a coffer dam assembly having an outer sleeve which is placed in sealing relation around the upper opening. A radiation shield sleeve is disposed in and reciprocable through the coffer dam sleeve. A fuel rod engaging member operates through the axial bore in the radiation shield sleeve to withdraw the fuel rod from its position in the reactor coolant channel into the shield, the shield snd rod then being removed. Loading is accomplished in the reverse procedure.

  9. Transpiring purging access probe for particulate laden or hazardous environments

    DOEpatents

    VanOsdol, John G

    2013-12-03

    An access probe for remote-sensing access through a viewing port, viewing volume, and access port into a vessel. The physical boundary around the viewing volume is partially formed by a porous sleeve lying between the viewing volume and a fluid conduit. In a first mode of operation, a fluid supplied to the fluid conduit encounters the porous sleeve and flows through the porous material to maintain the viewing volume free of ash or other matter. When additional fluid force is needed to clear the viewing volume, the pressure of the fluid flow is increased sufficiently to slidably translate the porous sleeve, greatly increasing the flow into the viewing volume. The porous sleeve is returned to position by an actuating spring. The access probe thereby provides for alternate modes of operation based on the pressure of an actuating fluid.

  10. Composite drill pipe and method for forming same

    DOEpatents

    Leslie, James C; Leslie, II, James C; Heard, James; Truong, Liem; Josephson, Marvin

    2014-04-15

    Metal inner and outer fittings configured, the inner fitting configured proximally with an external flange and projecting distally to form a cylindrical barrel and stepped down-in-diameter to form an abutment shoulder and then projecting further distally to form a radially inwardly angled and distally extending tapered inner sleeve. An outer sleeve defining a torque tube is configured with a cylindrical collar to fit over the barrel and is formed to be stepped up in diameter in alignment with the first abutment shoulder to then project distally forming a radially outwardly tapered and distally extending bonding surface to cooperate with the inner sleeve to cooperate with the inner sleeve in forming a annular diverging bonding cavity to receive the extremity of a composite pipe to abut against the abutment shoulders and to be bonded to the respective bonding surfaces by a bond.

  11. Magnesium Sulfate Reduced Opioid Consumption in Obese Patients Undergoing Sleeve Gastrectomy: a Prospective, Randomized Clinical Trial.

    PubMed

    Kizilcik, Nurcan; Koner, Ozge

    2018-05-12

    The purpose of the study was to investigate the effect of magnesium sulfate on pain management for pain after sleeve gastrectomy operation. A prospective, randomized, placebo-controlled clinical study. University hospital. Eighty patients undergoing sleeve gastrectomy. Visual analog scale for the evaluation of pain, sedation score, mean arterial pressure, heart rate, and total analgesic consumption was recorded. Serum magnesium levels were determined before the operation, at the end of the operation, and at 24 h. There were no significant differences between the groups with respect to demographics, and sedation scores. Cumulative morphine consumption and pain scores were found to be higher in the control group than the magnesium group. Perioperative use of magnesium sulfate reduced postoperative pain and opioid consumption in obese patients undergoing sleeve gastrectomy operations.

  12. Management Options for Twisted Gastric Tube after Laparoscopic Sleeve Gastrectomy.

    PubMed

    Abd Ellatif, Mohamed E; Abbas, Ashraf; El Nakeeb, Ayman; Magdy, Alaa; Salama, Asaad F; Bashah, Moataz M; Dawoud, Ibrahim; Gamal, Maged Ali; Sargsyan, Davit

    2017-09-01

    This study aims to determine the incidence, etiology, and management options for symptomatic gastric obstruction caused by axially twisted sleeve gastrectomy. In this retrospective study, we reviewed medical charts of all morbidly obese patients who underwent laparoscopic sleeve gastrectomy. Patients who developed gastric obstruction symptoms and were diagnosed with twisted sleeve gastrectomy were identified and included in this study. From October 2005 to December 2015, there are 3634 morbidly obese patients who underwent laparoscopic sleeve gastrectomy (LSG). Eighty-six (2.3%) patients developed symptoms of gastric obstruction. Forty-five (1.23%) patients were included in this study. The mean time of presentation was 59.8 days after surgery. Upper GI contrast study was done routinely, and it was positive for axial twist in 37 (82%) patients. Abdominal CT with oral and IV contrast was done in eight (18%) when swallow study was equivocal. Endoscopic treatment was successful in 43 patients (95.5%). Sixteen patients were successfully managed by endoscopic stenting, and 29 patients had balloon dilation. The average numbers of dilation sessions were 1.7. Out of these 29 patients, 18 responded well to a single session of dilatation and did not require any further dilatation sessions. Two patients who failed to respond to three subsequent sessions of balloon dilation underwent laparoscopic adhesiolysis and gastropexy. Endoscopic stenting is an effective tool in management of axial rotation of sleeved stomach. Balloon dilation can also be effective in selected cases. Few cases might require laparoscopic adhesiolysis and gastropexy.

  13. The effects of bariatric surgical procedures on the improvement of metabolic syndrome in morbidly obese patients: Comparison of laparoscopic sleeve gastrectomy versus laparoscopic Roux-en-Y gastric bypass.

    PubMed

    Kafalı, Mehmet Ertuğrul; Şahin, Mustafa; Ece, İlhan; Acar, Fahrettin; Yılmaz, Hüseyin; Alptekin, Hüsnü; Ateş, Leyla

    2017-01-01

    The objective of this study was to evaluate patients who underwent laparoscopic Roux-en-Y gastric bypass and laparoscopic sleeve gastrectomy in terms of weight loss, metabolic parameters, and postoperative complications. Data on patients who underwent laparoscopic Roux-en-Y gastric bypass and laparoscopic sleeve gastrectomy with a diagnosis of morbid obesity between January 2012 and June 2014 were retrospectively evaluated. Patients were compared in terms of age, sex, body mass index, duration of operation, American Society of Anesthesiologists score, perioperative complications, length of hospital stay, and long term follow-up results. During the study period, 91 patients (45 laparoscopic Roux-en-Y gastric bypass and 46 laparoscopic sleeve gastrectomy) underwent bariatric surgery. There was no difference between the two groups in terms of preoperative patient characteristics. Both groups showed statistically significant weight loss and improvement in co-morbidities when compared with the preoperative period. Weight loss and improvement in metabolic parameters were similar in both groups. The duration of operation and hospital stay was longer in the laparoscopic Roux-en-Y gastric bypass group. Furthermore, the rate of total complications was significantly lower in the laparoscopic sleeve gastrectomy group. Laparoscopic sleeve gastrectomy is a safe and effective method with a significantly lower complication rate and length of hospital stay than laparoscopic Roux-en-Y gastric bypass, with similar improvement rates in metabolic syndrome.

  14. Preliminary design package for prototype solar heating system

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A summary is given of the preliminary analysis and design activity on solar heating systems. The analysis was made without site specific data other than weather; therefore, the results indicate performance expected under these special conditions. Major items include system candidates, design approaches, trade studies and other special data required to evaluate the preliminary analysis and design. The program calls for the development and delivery of eight prototype solar heating and cooling systems for installation and operational test.

  15. System Design Package for SIMS Prototype System 3, Solar Heating and Domestic Hot Water

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A collation of documents and drawings are presented that describe a prototype solar heating and hot water system using liquid flat plate collectors and a gas or electric furnace energy subsystem. The system was designed for installation into a single-family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system are packaged for evaluation of the system with information sufficient to assemble a similar system.

  16. Prototype solar heating and cooling systems, including potable hot water

    NASA Technical Reports Server (NTRS)

    Bloomquist, D.; Oonk, R. L.

    1977-01-01

    Progress made in the development, delivery, and support of two prototype solar heating and cooling systems including potable hot water is reported. The system consists of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition. A comparison of the proposed Solaron Heat Pump and Solar Desiccant Heating and Cooling Systems, installation drawings, data on the Akron House at Akron, Ohio, and other program activities are included.

  17. Prototyping for LENS

    NASA Astrophysics Data System (ADS)

    Rasco, B. C.

    2012-03-01

    The Low-Energy Neutrino Spectroscopy (LENS) experiment will precisely measure the energy spectrum of low-energy solar neutrinos via charged-current neutrino reactions on indium. The LENS detector concept applies indium-loaded scintillator in an optically-segmented lattice geometry to achieve precise time and spatial resolution with unprecedented sensitivity for low-energy neutrino events. The LENS collaboration is currently developing prototypes that aim to demonstrate the performance and selectivity of the technology and to benchmark Monte Carlo simulations that will guide scaling to the full LENS instrument. Currently a 120 liter prototype, microLENS, is operating with pure scintillator (no indium loading) in the Kimballton Underground Research Facility (KURF). We will present results from initial measurements with microLENS and plans for a 400 liter prototype, miniLENS, using indium loaded scintillator that will be installed this summer.

  18. Design data brochure: SIMS prototype system 3

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A closed hydronic solar system is reported for space and hot water heating. Design, performance, and hardware specifications are presented sufficient for architectural engineers and contractors to procure, install, operate, and maintain a similar solar application.

  19. Technical Assessment of the Transette Transit System

    DOT National Transportation Integrated Search

    1981-10-01

    This report describes an assessment of the Transette system located at the Georgia Institute of Technology in Atlanta, Georgia. The Transette system is a unique, fully-automated, engineering prototype transportation test system installed on the campu...

  20. Welding fixture for nuclear fuel pin cladding assemblies

    DOEpatents

    Oakley, David J.; Feld, Sam H.

    1986-01-01

    A welding fixture for locating a driver sleeve about the open end of a nuclear fuel pin cladding. The welding fixture includes a holder provided with an open cavity having shoulders for properly positioning the driver sleeve, the end cap, and a soft, high temperature resistant plastic protective sleeve that surrounds a portion of the end cap stem. Ejected contaminant particles spewed forth by closure of the cladding by pulsed magnetic welding techniques are captured within a contamination trap formed in the holder for ultimate removal and disposal of contaminating particles along with the holder.

  1. Unna sleeve for neurotic excoriations.

    PubMed

    Paley, Kristina; Prevost, Noel; English, Joseph C

    2010-03-01

    Neurotic excoriations are self-induced skin lesions produced because of compulsive scratching or picking. We present the successful use of the venerable technique of an Unna boot used as an Unna sleeve for neurotic excoriations of the upper extremities.

  2. New nut and sleeve improve flared connections

    NASA Technical Reports Server (NTRS)

    Garrard, J. S.

    1965-01-01

    Improved nut and sleeve of standard stainless steel flared tube connection allows forces on the mating surfaces to be uniformly applied. This can be applied to pressurized fluid systems such as refrigeration, air conditioning, and hydraulic systems.

  3. Sleeve Push Technique: A Novel Method of Space Gaining.

    PubMed

    Verma, Sanjeev; Bhupali, Nameksh Raj; Gupta, Deepak Kumar; Singh, Sombir; Singh, Satinder Pal

    2018-01-01

    Space gaining is frequently required in orthodontics. Multiple loops were initially used for space gaining and alignment. The most common used mechanics for space gaining is the use of nickel-titanium open coil springs. The disadvantage of nickel-titanium coil spring is that they cannot be used until the arches are well aligned to receive the stiffer stainless steel wires. Therefore, a new method of gaining space during initial alignment and leveling has been developed and named as sleeve push technique (SPT). The nickel-titanium wires, i.e. 0.012 inches and 0.014 inches along with archwire sleeve (protective tubing) can be used in a modified way to gain space along with alignment. This method helps in gaining space right from day 1 of treatment. The archwire sleeve and nickel-titanium wire in this new SPT act as a mutually synergistic combination and provide the orthodontist with a completely new technique for space opening.

  4. Communication and logging hub for rapid prototyping of environmental sensors: presenting the Smartphone.

    NASA Astrophysics Data System (ADS)

    Hut, R.

    2017-12-01

    When desiging prototype sensors for environmental variables a critical step is a comparison campaign where the new sensor is compared to current state of the art sensors. In this step one of the headaches for researchers can be connecting their sensor to a logging or communication device. I present a simple solution: to use smartphone that scans for Bluetooth Low Energy transmissions and uploads any measurement to a data server. In this way the prototype sensor only has to transmit its measurement values over BLE, which can be done using off-the-shelf components. The sensors don't have to be physically connected to the phone, allowing for very rapid deployment of sensors in locations that have a communication hub (ie. phone) installed. The communication and logging hub consists of nothing more than a low cost Android smartphone running a dedicated app. The phone is encased in a waterproof box with a large powerbank and a solar panel. I will demonstrate this live at the Fall Meeting. By installing these phones along permanent WMO certified station locations, comparisons campaigns can use the "golden standard" from the WMO without much problems.

  5. Investigation of prototype volcano-surveillance network

    NASA Technical Reports Server (NTRS)

    Eaton, J. P. (Principal Investigator); Ward, P. L.

    1973-01-01

    The author has identified the following significant results. The equipment installed in the volcano surveillance network continues to work quite reliably and earthquakes are being recorded at all sites. A summary of platform receptions per day has been prepared.

  6. SafeConnect Solar - Final Scientific/Technical Report (Updated)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McNish, Zachary

    2016-02-03

    Final Scientific/Technical Report from Tier 0 SunShot Incubator award for hardware-based solution to reducing soft costs of installed solar. The primary objective of this project was for SafeConnect Solar (“SafeConnect”) to create working proof-of-concept hardware prototypes from its proprietary intellectual property and business concepts for a plug-and-play, safety-oriented hardware solution for photovoltaic solar systems. Specifically, SafeConnect sought to build prototypes of its “SmartBox” and related cabling and connectors, as well as the firmware needed to run the hardware. This hardware is designed to ensure a residential PV system installed with it can address all safety concerns that currently form themore » basis of AHJ electrical permitting and licensing requirements, thereby reducing the amount of permitting and specialized labor required on a residential PV system, and also opening up new sales channels and customer acquisition opportunities.« less

  7. Finalize field testing of cold climate heat pump (CCHP) based on tandem vapor injection compressors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Bo; Baxter, Van D.; Abdelaziz, Omar

    2017-03-01

    This report describes the system diagram and control algorithm of a prototype air-source cold climate heat pump (CCHP) using tandem vapor injection (VI) compressors. The prototype was installed in Fairbanks, Alaska and underwent field testing starting in 09/2016. The field testing results of the past six months, including compressor run time fractions, measured COPs and heating capacities, etc., are presented as a function of the ambient temperature. Two lessons learned are also reported.

  8. Development of a superconducting claw-pole linear test-rig

    NASA Astrophysics Data System (ADS)

    Radyjowski, Patryk; Keysan, Ozan; Burchell, Joseph; Mueller, Markus

    2016-04-01

    Superconducting generators can help to reduce the cost of energy for large offshore wind turbines, where the size and mass of the generator have a direct effect on the installation cost. However, existing superconducting generators are not as reliable as the alternative technologies. In this paper, a linear test prototype for a novel superconducting claw-pole topology, which has a stationary superconducting coil that eliminates the cryocooler coupler will be presented. The issues related to mechanical, electromagnetic and thermal aspects of the prototype will be presented.

  9. THROUGH-THE EARTH (TTE) SYSTEM AND THE IN-MINE POWER LINE (IMPL) SYSTEM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zvi H. Meiksin

    Work has progressed on both subsystems: the through-the-earth (TTE) system and the In-Mine Power Line (IMPL) system. After the Lab prototype of the IMPL system was perfected to function satisfactorily, the thrust of the work focused on building a first production prototype that can be installed and tested inside a mine. To obtain multi-channel voice communication through the TTE system, effort has proceeded to compress voice messages and make the format compatible with the power-line interface protocol.

  10. Development of infrared goggles and prototype

    NASA Astrophysics Data System (ADS)

    Tsuchimoto, Kouzou; Komatsubara, Shigeyuki; Fujikawa, Masaru; Otsuka, Toshiaki; Kan, Moriyasu; Matsumura, Norihide

    2006-05-01

    We aimed at developing a hands free type practical wearable thermography which will not hinder walking or working of the person wearing the equipment. We installed a small format camera core module, which was recently developed, into the fire fighter's helmet and incorporated image transmission function over radio to the equipment. We combined this thermography with a see-through type head mount display, and called it "Infrared Goggles". A prototype was developed for verification test of lifesaving support system in fire fighting activities.

  11. Thermocouple psychrometer measurements of in situ water potential changes in heated welded tuff

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mao, Nai-hsien; Wang, H.F.

    1991-05-01

    Ten thermocouple psychrometers (TCPs) to measure water potential (WP) were installed in three holes in G-Tunnel at the Nevada Test Site as part of the Prototype Engineered Barrier System Field Tests. These integrated tests measured several parameters as a function of location and time within a few meters of a heater emplaced in welded tuff. The primary goal of the TCP experiment was to find out whether the combination of laboratory calibration and field use of the TCP can provide useful data for determining the change of moisture condition in the field. We calibrated the TCPs in NaCl solutions upmore » to 80{degree}C(176{degree}F) in the laboratory. In two holes, we used rubber sleeves and packers to house TCPs, and in the third hole, we used foam. All three holes were grouted behind the TCP assemblages. Field results of the heater test showed that small temperature gradients were present for all measurements. Nevertheless, the WP calibration made the necessary correction for the nonisothermal condition. A drying and re-wetting cycle peaked at about day 140 with a WP of -65 bar in borehole P3, located below the heater. A similar cycle but reduced in scale was found at about day 175 with a WP of -45 bar in borehole P2, above the heater. This difference in drying behavior above and below the heater was also observed from neutron data and was explained as a gravity effect. As temperatures increased, the evaporation rate of pore water increased, In unfractured rock, the gas-phase flow was primarily outward. Water condensed above the heater would drain back to keep the boiling region wet, but water condensed below the heater would drain away from the boiling region. This conceptual model explained both the time and magnitude differences for data from holes above and below the heater. 7 refs., 14 figs., 2 tabs.« less

  12. Clinical practice guidelines for rest orthosis, knee sleeves, and unloading knee braces in knee osteoarthritis.

    PubMed

    Beaudreuil, Johann; Bendaya, Samy; Faucher, Marc; Coudeyre, Emmanuel; Ribinik, Patricia; Revel, Michel; Rannou, François

    2009-12-01

    To develop clinical practice guidelines concerning the use of bracing--rest orthosis, knee sleeves and unloading knee braces--for knee osteoarthritis. The French Physical Medicine and Rehabilitation Society (SOFMER) methodology, associating a systematic literature review, collection of everyday clinical practice, and external review by multidisciplinary expert panel, was used. Few high-level studies of bracing for knee osteoarthritis were found. No evidence exists for the effectiveness of rest orthosis. Evidence for knee sleeves suggests that they decrease pain in knee osteoarthritis, and their use is associated with subjective improvement. These actions do not appear to depend on a local thermal effect. The effectiveness of knee sleeves for disability is not demonstrated for knee osteoarthritis. Short- and mid-term follow-up indicates that valgus knee bracing decreases pain and disability in medial knee osteoarthritis, appears to be more effective than knee sleeves, and improves quality of life, knee proprioception, quadriceps strength, and gait symmetry, and decreases compressive loads in the medial femoro-tibial compartment. However, results of response to valgus knee bracing remain inconsistent; discomfort and side effects can result. Thrombophlebitis of the lower limbs has been reported with the braces. Braces, whatever kind, are infrequently prescribed in clinical practice for osteoarthritis of the lower limbs. Modest evidence exists for the effectiveness of bracing--rest orthosis, knee sleeves and unloading knee braces--for knee osteoarthritis, with only low level recommendations for its use. Braces are prescribed infrequently in French clinical practice for osteoarthritis of the knee. Randomized clinical trials concerning bracing in knee osteoarthritis are still necessary.

  13. [Outcomes, controversies and gastric volume after laparoscopic sleeve gastrectomy in the treatment of obesity].

    PubMed

    García-Díaz, Juan José; Ferrer-Márquez, Manuel; Moreno-Serrano, Almudena; Barreto-Rios, Rogelio; Alarcón-Rodríguez, Raquel; Ferrer-Ayza, Manuel

    2016-01-01

    Laparoscopic sleeve gastrectomy is a surgical procedure for the treatment of morbid obesity. However, there are still controversies regarding its efficiency in terms of weight reduction and incidence of complications. In this prospective study, the experience is presented of a referral centre for the treatment of morbid obesity with laparoscopic sleeve gastrectomy. A prospective study on 73 patients subjected to laparoscopic sleeve gastrectomy from February 2009 to September 2013. Patients were followed-up for a period of 12 months, evaluating the development of complications, reduction of gastric volume, and the weight loss associated with the surgery, as well as their impact on the improvement of comorbidities present at beginning of the study. There was a statistically a significantly reduction between the preoperative body mass index (BMI) and the BMI at 12 months after laparoscopic sleeve gastrectomy (p < 0.001), despite there being an increase in the gastric volume during follow-up, measured at one month and 12 months after surgery (p < 0.001). Five patients (6.85%) had complications, with none of them serious and with no deaths in the whole series. Laparoscopic sleeve gastrectomy is a safe and effective technique for the treatment of morbid obesity. Its use is associated with a significant reduction in the presence of comorbidities associated with obesity. Multicentre studies with a longer period of monitoring are required to confirm the efficacy and safety of this surgical technique. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  14. Seismic retrofit of spliced sleeve connections for precast bridge piers.

    DOT National Transportation Integrated Search

    2017-03-01

    Grouted Splice Sleeve (GSS) connectors are being considered for connecting bridge columns, footings, and pier caps in Accelerated Bridge Construction (ABC). A repair technique for precast reinforced concrete bridge column-to-footing and column-to-pie...

  15. Three-Dimensional Bio-Printed Scaffold Sleeves With Mesenchymal Stem Cells for Enhancement of Tendon-to-Bone Healing in Anterior Cruciate Ligament Reconstruction Using Soft-Tissue Tendon Graft.

    PubMed

    Park, Sin Hyung; Choi, Yeong-Jin; Moon, Sang Won; Lee, Byung Hoon; Shim, Jin-Hyung; Cho, Dong-Woo; Wang, Joon Ho

    2018-01-01

    To investigate the efficacy of the insertion of 3-dimensional (3D) bio-printed scaffold sleeves seeded with mesenchymal stem cells (MSCs) to enhance osteointegration between the tendon and tunnel bone in anterior cruciate ligament (ACL) reconstruction in a rabbit model. Scaffold sleeves were fabricated by 3D bio-printing. Before ACL reconstruction, MSCs were seeded into the scaffold sleeves. ACL reconstruction with hamstring tendon was performed on both legs of 15 adult rabbits (aged 12 weeks). We implanted 15 bone tunnels with scaffold sleeves with MSCs and implanted another 15 bone tunnels with scaffold sleeves without MSCs before passing the graft. The specimens were harvested at 4, 8, and 12 weeks. H&E staining, immunohistochemical staining of type II collagen, and micro-computed tomography of the tunnel cross-sectional area were evaluated. Histologic assessment was conducted with a histologic scoring system. In the histologic assessment, a smooth bone-to-tendon transition through broad fibrocartilage formation was identified in the treatment group, and the interface zone showed abundant type II collagen production on immunohistochemical staining. Bone-tendon healing histologic scores were significantly higher in the treatment group than in the control group at all time points. Micro-computed tomography at 12 weeks showed smaller tibial (control, 9.4 ± 0.9 mm 2 ; treatment, 5.8 ± 2.9 mm 2 ; P = .044) and femoral (control, 9.6 ± 2.9 mm 2 ; treatment, 6.0 ± 1.0 mm 2 ; P = .03) bone-tunnel areas in the treated group than in the control group. The 3D bio-printed scaffold sleeve with MSCs exhibited excellent results in osteointegration enhancement between the tendon and tunnel bone in ACL reconstruction in a rabbit model. If secure biological healing between the tendon graft and tunnel bone can be induced in the early postoperative period, earlier, more successful rehabilitation may be facilitated. Three-dimensional bio-printed scaffold sleeves with MSCs have the potential to accelerate bone-tendon healing in ACL reconstruction. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. PANDA Muon System Prototype

    NASA Astrophysics Data System (ADS)

    Abazov, Victor; Alexeev, Gennady; Alexeev, Maxim; Frolov, Vladimir; Golovanov, Georgy; Kutuzov, Sergey; Piskun, Alexei; Samartsev, Alexander; Tokmenin, Valeri; Verkheev, Alexander; Vertogradov, Leonid; Zhuravlev, Nikolai

    2018-04-01

    The PANDA Experiment will be one of the key experiments at the Facility for Antiproton and Ion Research (FAIR) which is under construction now in the territory of the GSI Helmholtz Centre for Heavy Ion Research in Darmstadt, Germany. PANDA is aimed to study hadron spectroscopy and various topics of the weak and strong forces. Muon System is chosen as the most suitable technology for detecting the muons. The Prototype of the PANDA Muon System is installed on the test beam line T9 at the Proton Synchrotron (PS) at CERN. Status of the PANDA Muon System prototype is presented with few preliminary results.

  17. Dark Matter Annihilation Cross-Section Limits of Dwarf Spheroidal Galaxies with the High Altitude Water Cherenkov (HAWC) Gamma-Ray Observatory and on the design of a Water Cherenkov Detector Prototype

    NASA Astrophysics Data System (ADS)

    Proper, Megan Longo

    I present an indirect search for Dark Matter using the High Altitude Water Cherenkov (HAWC) gamma-ray observatory. There is significant evidence for dark matter within the known Universe, and we can set constraints on the dark matter annihilation cross-section using dark matter rich sources. Dwarf spheroidal galaxies (dSphs) are low luminosity galaxies with little to no gas or dust, or recent star formation. In addition, the total mass of a dwarf spheroidal galaxy, as inferred from gravitational effects observed within the galaxy, is many times more than the luminous mass, making them extremely dark matter rich. For these reasons dSphs are prime targets for indirect dark matter searches with gamma rays. Dark matter annihilation cross-section limits are presented for 14 dSphs within the HAWC field of view, as well as a combined limit with all sources. The limits presented here are for dark matter masses ranging from 0.5 TeV to 1000 TeV. At lower dark matter masses, the HAWC-111 limits are not competitive with other gamma-ray experiments, however it will be shown that HAWC is currently dominating in the higher dark matter mass range. The HAWC observatory is a water Cherenkov detector and consists of 300 Water Cherenkov Detectors (WCDs). The detector is located at 4100 m above sea level in the Sierra Negra region of Mexico at latitude 18°59'41" N and longitude 97°18'28" W. Each WCD is instrumented with three 8 inch photomultiplier tubes (PMTs) and one 10 inch high efficiency PMT, anchored to the bottom of a 5 m deep by 7.3 m diameter steel tank. The tank contains a multilayer hermetic plastic bag, called a bladder, which holds 200,000 L of ultra-purified water. I will also present the design, deployment, and operation of a WCD prototype for HAWC built at Colorado State University (CSU). The CSU WCD was the only full-size prototype outside of the HAWC site. It was instrumented with 7 HAWC PMTs and scintillator paddles both under and above the volume of water. In addition, the CSU WCD was equipped with the same laser calibration system that is deployed at the HAWC site, as well as the same electronics and data acquisition system. The WCD prototype served as a testbed for the different subsystems of the HAWC observatory. During the three different installations of the prototype, many aspects of the detector design and performance were tested including: tank construction, bladder installation and performance, PMT installation and performance, roof design, water filtration and filling, muon coincidence measurements and calibration system. The experience gained from the CSU prototype was invaluable to the overall design and installation of the HAWC detector.

  18. Prototype solar heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1979-01-01

    A combination of monthly progress reports are presented. It contains a summary of activities and progress made from November 1, 1978, to February 28, 1979. The effort calls for the development, manufacture, test, system installation, maintenance, problem resolution, and performance evaluation.

  19. Geothermal switch heater installation, testing and monitoring : phases 1 & 2.

    DOT National Transportation Integrated Search

    2016-07-01

    Transportation Technology Center, Inc. (TTCI), Norfolk Southern (NS), and John A. Volpe National Transportation Systems Center (Volpe) completed Phases 1 and 2 of a project on a working prototype geothermal switch heating system designed to test the ...

  20. Welding fixture for nuclear fuel pin cladding assemblies

    DOEpatents

    Oakley, D.J.; Feld, S.H.

    1984-02-22

    A welding fixture is described for locating a driver sleeve about the open end of a nuclear fuel pin cladding. The welding fixture includes a holder provided with an open cavity having shoulders for properly positioning the driver sleeve, the end cap, and a soft, high temperature resistant plastic protective sleeve that surrounds a portion of the end cap stem. Ejected contaminant particles spewed forth by closure of the cladding by pulsed magnetic welding techniques are captured within a contamination trap formed in the holder for ultimate removal and disposal of contaminating particles along with the holder.

  1. Effect of insulator sleeve material on the x-ray emission from a plasma focus device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hussain, S.; Badar, M. A.; Shafiq, M.

    The effect of insulator sleeve material on x-ray emission from a 2.3 kJ Mather type plasma focus device operated in argon-hydrogen mixture is investigated. The time and space resolved x-ray emission characteristics are studied by using a three channel p-i-n diode x-ray spectrometer and a multipinhole camera. The x-ray emission depends on the volumetric ratio of argon-hydrogen mixture as well as the filling pressure and the highest x-ray emission is observed for a volumetric ratio 40% Ar to 60%H{sub 2} at 2.5 mbar filling pressure. The fused silica insulator sleeve produces the highest x-ray emission whereas nonceramic insulator sleeves suchmore » as nylon, Perspex, or Teflon does not produce focus or x-rays. The pinhole images of the x-ray emitting zones reveal that the contribution of the Cu K{alpha} line is weak and plasma x-rays are intense. The highest plasma electron temperature is estimated to be 3.3 and 3.6 keV for Pyrex glass and fused silica insulator sleeves, respectively. It is speculated that the higher surface resistivity of fused silica is responsible for enhanced x-ray emission and plasma electron temperature.« less

  2. A new bipolar Qtrim power supply system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mi, C.; Bruno, D.; Drozd, J.

    2015-05-03

    This year marks the 15th run of RHIC (Relativistic Heavy Ion Collider) operations. The reliability of superconducting magnet power supplies is one of the essential factors in the entire accelerator complex. Besides maintaining existing power supplies and their associated equipment, newly designed systems are also required based on the physicist’s latest requirements. A bipolar power supply was required for this year’s main quadruple trim power supply. This paper will explain the design, prototype, testing, installation and operation of this recently installed power supply system.

  3. Proceedings of the 16th Project Integration Meeting

    NASA Technical Reports Server (NTRS)

    Mcdonald, R. R.

    1980-01-01

    The principal achievement of the Low Cost Solar Array Project in 1980 was the attainment of $2.80/Wp Technical Readiness, and that processes and equipment now commercially available can make possible a deliverable product in 1982. A prototype array for intermediate load applications was demonstrated using frameless modules. It was proof tested to 40 lb/sq ft loading, and priced at $24/sq m, including array fabrication, module installation, shipping to the site and site installation for quantities of 20 MW.

  4. Install active/passive neutron examination and assay (APNEA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1996-04-01

    This document describes activities pertinent to the installation of the prototype Active/Passive Neutron Examination and Assay (APNEA) system built in Area 336 into its specially designed trailer. It also documents the basic theory of operation, design and protective features, basic personnel training, and the proposed characterization site location at Lockheed Martin Specialty Components, Inc., (Specialty Components) with the estimated 10 mrem/year boundary. Additionally, the document includes the Preventive Change Analysis (PCA) form, and a checklist of items for verification prior to unrestricted system use.

  5. EUSO-TA prototype telescope

    NASA Astrophysics Data System (ADS)

    Bisconti, Francesca; JEM-EUSO Collaboration

    2016-07-01

    EUSO-TA is one of the prototypes developed for the JEM-EUSO project, a space-based large field-of-view telescope to observe the fluorescence light emitted by cosmic ray air showers in the atmosphere. EUSO-TA is a ground-based prototype located at the Telescope Array (TA) site in Utah, USA, where an Electron Light Source and a Central Laser Facility are installed. The purpose of the EUSO-TA project is to calibrate the prototype with the TA fluorescence detector in presence of well-known light sources and cosmic ray air showers. In 2015, the detector started the first measurements and tests using the mentioned light sources have been performed successfully. A first cosmic ray candidate has been observed, as well as stars of different magnitude and color index. Since Silicon Photo-Multipliers (SiPMs) are very promising for fluorescence telescopes of next generation, they are under consideration for the realization of a new prototype of EUSO Photo Detector Module (PDM). The response of this sensor type is under investigation through simulations and laboratory experimentation.

  6. Changes in the makeup of bariatric surgery: a national increase in use of laparoscopic sleeve gastrectomy.

    PubMed

    Nguyen, Ninh T; Nguyen, Brian; Gebhart, Alana; Hohmann, Samuel

    2013-02-01

    Laparoscopic sleeve gastrectomy is gaining popularity in the US; however, there has been no study examining the use of sleeve gastrectomy at a national level and its impact on the use of other bariatric operations. The aim of this study was to examine contemporary changes in use and outcomes of bariatric surgery performed at academic medical centers. Using ICD-9 diagnosis and procedure codes, clinical data obtained from the University HealthSystem Consortium database for all bariatric procedures performed for the treatment of morbid obesity between October 1, 2008 and September 30, 2012 were reviewed. Quartile trends in use for the 3 most commonly performed bariatric operations were examined, and a comparison of perioperative outcomes between procedures was performed within a subset of patients with minor severity of illness. A total of 60,738 bariatric procedures were examined. In 2008, the makeup of bariatric surgery consisted primarily of gastric bypass (66.8% laparoscopic, 8.6% open), followed by laparoscopic gastric banding (23.8%). In 2012, there was a precipitous increase in use of laparoscopic sleeve gastrectomy (36.3 %), with a concurrent reduction in the use of laparoscopic (56.4%) and open (3.2%) gastric bypass, and a major reduction in laparoscopic gastric banding (4.1%). The length of hospital stay, in-hospital morbidity and mortality, and costs for laparoscopic sleeve gastrectomy were found to be between those of laparoscopic gastric banding and laparoscopic gastric bypass. Within the context of academic medical centers, there has been a recent change in the makeup of bariatric surgery. There has been an increase in the use of laparoscopic sleeve gastrectomy, which has had an impact primarily on reducing the use of laparoscopic adjustable gastric banding. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Method for hot press forming articles

    DOEpatents

    Baker, Robert R.; Hartsock, Dale L.

    1982-01-01

    This disclosure relates to an improved method for achieving the best bond strength and for minimizing distortion and cracking of hot pressed articles. In particular, in a method for hot press forming both an outer facing circumferential surface of and an inner portion of a hub, and of bonding that so-formed outer facing circumferential surface to an inner facing circumferential surface of a pre-formed ring thereby to form an article, the following improvement is made. Normally, in this method, the outside ring is restrained by a restraining sleeve of ring-shaped cross-section having an inside diameter. A die member, used to hot press form the hub, is so-formed as to have an outside diameter sized to engage the inside diameter of the restraining sleeve in a manner permitting relative movement therebetween. The improved method is one in which several pairs of matched restraining sleeve and die member are formed with each matched pair having a predetermined diameter. The predetermined diameter of each matched pair is different from another matched pair by stepped increments. The largest inside diameter of a restraining sleeve is equal to the diameter of the outer facing circumferential surface of the hub. Each pair of the matched restraining sleeve and die member is used to form an article in which an inside hub is bonded to an outside ring. The several samples so-formed are evaluated to determine which sample has the best bond formed between the hub and the ring with the least or no cracking or distortion in the ring portion of the article. Thereafter, the matched restraining sleeve and die member which form the article having the best bonding characteristics and least distortion cracking is then used for repeated formations of articles.

  8. Hospital Variation in Perioperative Complications for Laparoscopic Sleeve Gastrectomy in Michigan

    PubMed Central

    Pradarelli, Jason C.; Varban, Oliver A.; Ghaferi, Amir A.; Weiner, Matthew; Carlin, Arthur M.; Dimick, Justin B.

    2015-01-01

    Structured Abstract Background Laparoscopic sleeve gastrectomy has recently surpassed gastric bypass and laparoscopic adjustable gastric banding as the most common weight-loss procedure. Previously, substantial concerns existed regarding variation in perioperative safety with bariatric surgery. This study aimed to assess rates of perioperative complications for laparoscopic sleeve gastrectomy across hospitals and in relation to procedure volume. Study Design We analyzed 8,693 patients who underwent laparoscopic sleeve gastrectomy from 2013 through 2014 across 40 hospitals in the Michigan Bariatric Surgery Collaborative. Mixed-effects logistic regression was used to assess hospital variation in risk- and reliability-adjusted rates of overall and serious 30-day complications and their relationship with hospital annual stapling procedure volume (gastric bypass and sleeve gastrectomy). Results Overall, 5.4% of patients experienced perioperative complications. Adjusted rates of overall complications varied three-fold across hospitals, ranging from 3.6% (95% CI, 1.9–6.8%) to 11.0% (95% CI, 7.7–15.5%). Serious complications occurred in just 1.2% of patients and varied minimally. In this analysis, hospital volume was not associated with overall or serious complications. The 1 hospital with significantly lower overall complication rates was high-volume (≥125 procedures/year); however, of the 4 hospitals with significantly higher complication rates, 3 were medium-volume (50–124 procedures/year) and 1 was high-volume. The remaining hospitals were not significantly different than the cohort mean. Conclusions Serious complications among patients undergoing laparoscopic sleeve gastrectomy were relatively infrequent. Rates of overall complications varied widely across Michigan hospitals enrolled in a quality collaborative, although this variation was unrelated to volume standards required for accreditation as a comprehensive bariatric surgery center. PMID:26506567

  9. Thermal characterization of phacoemulsification probes operated in axial and torsional modes.

    PubMed

    Zacharias, Jaime

    2015-01-01

    To analyze temperature increases and identify potential sources of heat generated when sleeved and sleeveless phacoemulsification probes were operated in axial and torsional modes using the Infiniti Vision System with the Ozil torsional handpiece. Phacodynamics Laboratory, Pasteur Ophthalmic Clinic, Santiago, Chile. Experimental study. Two computer-controlled thermal transfer systems were developed to evaluate the contribution of internal metal stress and tip-to-sleeve friction on heat generation during phacoemulsification using axial and torsional ultrasound modalities. Both systems incorporated infrared thermal imaging and used a black-body film to accurately capture temperature measurements. Axial mode was consistently associated with greater temperature increases than torsional mode whether tips were operated with or without sleeves. In tests involving bare tips, axial mode and torsional mode peaked at 51.7°C and 34.2°C, respectively. In an example using sleeved tips in which a 30.0 g load was applied for 1 second, temperatures for axial mode reached 45°C and for torsional mode, 38°C. Friction between the sleeved probe and the incisional wall contributed more significantly to the temperature increase than internal metal stress regardless of the mode used. In all experiments, the temperature increase observed with axial mode was greater than that observed with torsional mode, even when conditions such as power or amplitude and flow rate were varied. Tip-to-sleeve friction was a more dominant source of phaco probe heating than internal metal stress. The temperature increase due to internal metal stress was greater with axial mode than with torsional mode. Dr. Zacharias received research funding from Alcon Laboratories, Inc., to conduct this study. He has no financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Intra-thoracic Sleeve Migration (ITSM): an Underreported Phenomenon After Laparoscopic Sleeve Gastrectomy.

    PubMed

    Saber, Alan A; Shoar, Saeed; Khoursheed, Mousa

    2017-08-01

    Despite its technical simplicity, laparoscopic sleeve gastrectomy (LSG) complications are increasingly reported. Intra-thoracic sleeve migration (ITSM ) is a rare complication after LSG which has been inconsistently addressed in the literature. The purpose of this study was to emphasize ITSM occurrence after LSG and evaluate the perioperative factors associated with its development. Between January and July 2016, LSG patients diagnosed with ITSM at two bariatric surgery departments were identified. Perioperative factors were assessed for all the patients and compared between two groups, LSG alone and LSG with concomitant hiatal hernia (HH) repair (HHR). A total of 19 patients (6 males and 13 females) were included. Central obesity was present in 18 patients (94.7%). Nine patients (47.4%) had concomitant hiatal hernia repair during their original LSG. Post-LSG GERD (94.7%) (38.9% de novo and 61.1% recurrent) and post-LSG constipation (57.9%) were commonly associated with ITSM. Severe refractory GERD was the most common presentation for ITSM (94.7%), followed by epigastric pain (47.4%), persistent nausea/vomiting (36.8%), and dysphagia (21.1%). Time interval between primary LSG and ITSM diagnosis ranged from 1 day to 3 years. Patients with LSG and concomitant HHR presented with higher post-LSG BMI compared to the LSG patients (37 ± 6.4 kg/m 2 vs. 30.1 ± 6.3 kg/m 2 , p = 0.03). All the patients underwent successful reduction of ITSM and subsequent HHR. Central obesity, chronic constipation, post-LSG GERD, and concomitant HHR are commonly seen in post-laparoscopic sleeve gastrectomy intra-thoracic sleeve migration.

  11. EC03-0058-2

    NASA Image and Video Library

    2003-03-04

    Aerovironment technicians carefully line up attachments as a fuel cell electrical system is installed on the Helios Prototype solar powered flying wing. The fuel cell system will power the aircraft at night during NASA-sponsored long-endurance demonstration flight in the summer of 2003.

  12. Applying Hypertext Structures to Software Documentation.

    ERIC Educational Resources Information Center

    French, James C.; And Others

    1997-01-01

    Describes a prototype system for software documentation management called SLEUTH (Software Literacy Enhancing Usefulness to Humans) being developed at the University of Virginia. Highlights include information retrieval techniques, hypertext links that are installed automatically, a WAIS (Wide Area Information Server) search engine, user…

  13. Solar heating and cooling systems design and development

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The development and delivery of eight prototype solar heating and cooling systems for installation and operational test was reported. Two heating and six heating and cooling units will be delivered for single family residences, multiple family residences and commercial applications.

  14. High-Temperature Helical-Tube Solar Receiver

    NASA Technical Reports Server (NTRS)

    Robertson, C. S., Jr.; Mccreight, L.

    1984-01-01

    Solar-thermal receiver used with circular parabolic concentrator to supply about 58 kW thermal power to Brayton engine or industrial process. Solar radiation focused into open end of cylindrical ceramic thermal inertial sleeve 8 in. in diameter that reradiates energy to helical heatexchanger tube surrounding sleeve.

  15. 77 FR 39188 - Airworthiness Directives; the Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-02

    ... existing AD currently requires repetitive inspections to detect discrepancies of the wiring and surrounding... new sleeves, for certain airplanes; and repair or replacement of the wiring and sleeves with new parts... currently requires repetitive inspections to detect discrepancies of the wiring and surrounding Teflon...

  16. Development and Testing of a Friction-Based Post-Installable Fiber-Optic Monitoring System for Subsea Applications

    NASA Technical Reports Server (NTRS)

    Bentley, Nicole L.; Brower, David V.; Le, Suy Q.; Seaman, Calvin H.; Tang, Henry H.

    2017-01-01

    This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system capable of measuring pressure, strain, and temperature that can be deployed on existing subsea structures. A summary is provided of the design concept, prototype development, prototype performance testing, and subsequent design refinements of the device. The results of laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are also included. Limitations of the initial concept were identified during testing and future design improvements were proposed and later implemented. These new features enhance the coupling of the sensor device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on flowlines, risers, and other subsea structures. The work described in this paper investigates the design and test of a friction-based coupling device (herein referred to as a friction clamp) which is suitable for pipelines and structures that are suspended in the water column as well as for those that are resting on the seabed. The monitoring elements consist of fiberoptic sensors that are bonded to a stainless steel clamshell assembly with a high-friction surface coating. The friction clamp incorporates a single hinge design to facilitate installation of the clamp and dual rows of opposing fasteners to distribute the clamping force along the structure. The friction clamp can be modified to be installed by commercial divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance technologies that will benefit the environment, the public, and commercial industries.

  17. UV reactor flow visualization and mixing quantification using three-dimensional laser-induced fluorescence.

    PubMed

    Gandhi, Varun; Roberts, Philip J W; Stoesser, Thorsten; Wright, Harold; Kim, Jae-Hong

    2011-07-01

    Three-dimensional laser-induced fluorescence (3DLIF) was applied to visualize and quantitatively analyze mixing in a lab-scale UV reactor consisting of one lamp sleeve placed perpendicular to flow. The recirculation zone and the von Karman vortex shedding that commonly occur in flows around bluff bodies were successfully visualized. Multiple flow paths were analyzed by injecting the dye at various heights with respect to the lamp sleeve. A major difference in these pathways was the amount of dye that traveled close to the sleeve, i.e., a zone of higher residence time and higher UV exposure. Paths away from the center height had higher velocities and hence minimal influence by the presence of sleeve. Approach length was also characterized in order to increase the probability of microbes entering the region around the UV lamp. The 3DLIF technique developed in this study is expected to provide new insight on UV dose delivery useful for the design and optimization of UV reactors. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Repair boundary for parent tube indications within the upper joint zone of hybrid expansion joint (HEJ) sleeved tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cullen, W.K.; Keating, R.F.

    1997-02-01

    In the Spring and Fall of 1994, and the Spring of 1995, crack-like indications were found in the upper hybrid expansion joint (HEJ) region of Steam Generator (S/G) tubes which had been sleeved using Westinghouse HEJ sleeves. As a result of these findings, analytic and test evaluations were performed to assess the effect of the degradation on the structural, and leakage, integrity of the sleeve/tube joint relative to the requirements of the United States Nuclear Regulatory Commission`s (NRC) draft Regulatory Guide (RG) 1.121. The results of these evaluations demonstrated that tubes with implied or known crack-like circumferential parent tube indicationsmore » (PTIs) located 1.1 inches or farther below the bottom of the hardroll upper transition, have sufficient, and significant, integrity relative to the requirements of RG 1.121. Thus, the purpose of this report is to provide background information related to the justification of the modified tube repair boundary.« less

  19. The effects of sleeve gastectomy on gastro-esophageal reflux and gastro-esophageal motility.

    PubMed

    Hayat, Jamal O; Wan, Andrew

    2014-05-01

    Sleeve gastrectomy is an increasingly performed bariatric procedure associated with low morbidity and good short to medium term effects on weight loss and comorbid conditions. Studies assessing the prevalence of post-operative gastro-esophageal reflux disease (GERD), show sleeve gastrectomy may provoke de novo GERD symptoms or worsening of pre-existing GERD. Pathophysiological mechanisms of GERD after sleeve gastrectomy include a hypotensive lower esophageal sphincter, increased gastro-esophageal pressure gradient and intra-thoracic migration of the remnant stomach. A reduction in the compliance of the gastric remnant may provoke an increase in transient lower esophageal sphincter relaxations. Time-resolved MRI suggests relative gastric stasis in the proximal remnant and increased emptying from the antrum. A lack of standardisation of technique, along with heterogeneity of studies assessing GERD may explain the wide variability in reported results. Simultaneous and careful repair of an associated hiatus hernia may result in a reduction in the prevalence of post-operative GERD.

  20. Apparatus for enhancing tissue repair in mammals

    NASA Technical Reports Server (NTRS)

    Goodwin, Thomas J. (Inventor); Parker, Clayton R. (Inventor)

    2007-01-01

    An apparatus is disclosed for enhancing tissue repair in mammals, with the apparatus comprising: a sleeve for encircling a portion of a mammalian body part, said sleeve comprising an electrically conductive coil capable of generating an electromagnetic field when an electrical current is applied thereto, means for supporting the sleeve on the mammalian body part; and means for supplying the electrically conductive coil with a square wave time varying electrical current sufficient to create a time varying electromagnetic force of from approximately 0.05 gauss to 0.05 gauss within the interior of the coil in order that when the sleeve is placed on a mammalian body part and the time varying electromagnetic force of from approximately 0.05 gauss to 0.05 gauss is generated on the mammalian body part for an extended period of time, tissue regeneration within the mammalian body part is increased to a rate in excess of the normal tissue regeneration rate that would occur without application of the time varying electromagnetic force.

  1. Study of Pyrex and quartz insulators contamination effect on the X-ray intensity in a 4-kJ plasma focus device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habibi, M., E-mail: mortezahabibi@aut.ac.ir; Sharifi, R.; Amrollahi, R.

    2013-12-15

    The variation of the X-ray intensity has been investigated with the Pyrex and quartz insulators surface contamination in a 4-kJ plasma focus device with argon gas at 11.5-kV charging voltage. Elemental analysis (EDAX) showed that the Cu evaporated from the electrode material and was deposited on the sleeve surface improves the breakdown conditions. A small level of sleeve contamination by copper is found to be essential for good focusing action and high HXR intensity. The SEM imaging showed the grain-type structure of Cu formed on the surface and it changed the surface property. Resistance measurements of original and coated Pyrexmore » surface proved that the copper deposition on the sleeve surface will reduce its resistance as compared to the almost infinitely large resistance of the uncontaminated sleeve. As the contamination is surpassed to some critical level, the HXR intensity from the device is deteriorated.« less

  2. Piano jacket for perceiving and playing music for patients with cerebral palsy.

    PubMed

    Lampe, Renée; Turova, Varvara; Alves-Pinto, Ana

    2017-12-23

    Patients with cerebral palsy with severe motor disabilities are limited not only in everyday life activities but also in choice of their hobbies. Playing a musical instrument is for the majority not possible, even though music constitutes a central component of many relaxation activities for people with disabilities. To give affected patients the opportunity to make music and to learn piano playing through somatosensory perception, a prototype of piano jacket was developed. A cycling jacket was equipped with boxes, each representing a musical note, incorporated into the sleeves. Each box contains vibration motors and LEDs. These can be used to translate the sequences of piano key presses performed at an external E-piano. An additional operation mode allows the user to actively play a melody himself by touching the same boxes that also incorporate touch sensor components. A working prototype of the piano jacket was developed. The sensory piano jacket provides patients with cerebral palsy and contractures the possibility to develop sensorimotor skills, motor abilities and participation in music-related activities. The jacket is planned to be used in music lessons. Implications for Rehabilitation The system is suitable even for patients with severe motor disabilities and especially joint contractures. Excellent handling through large easily accessible communication buttons. All building blocks are held in a garment, which allows for easy portability and gripping comfort.

  3. Science Operations for the 2008 NASA Lunar Analog Field Test at Black Point Lava Flow, Arizona

    NASA Technical Reports Server (NTRS)

    Garry W. D.; Horz, F.; Lofgren, G. E.; Kring, D. A.; Chapman, M. G.; Eppler, D. B.; Rice, J. W., Jr.; Nelson, J.; Gernhardt, M. L.; Walheim, R. J.

    2009-01-01

    Surface science operations on the Moon will require merging lessons from Apollo with new operation concepts that exploit the Constellation Lunar Architecture. Prototypes of lunar vehicles and robots are already under development and will change the way we conduct science operations compared to Apollo. To prepare for future surface operations on the Moon, NASA, along with several supporting agencies and institutions, conducted a high-fidelity lunar mission simulation with prototypes of the small pressurized rover (SPR) and unpressurized rover (UPR) (Fig. 1) at Black Point lava flow (Fig. 2), 40 km north of Flagstaff, Arizona from Oct. 19-31, 2008. This field test was primarily intended to evaluate and compare the surface mobility afforded by unpressurized and pressurized rovers, the latter critically depending on the innovative suit-port concept for efficient egress and ingress. The UPR vehicle transports two astronauts who remain in their EVA suits at all times, whereas the SPR concept enables astronauts to remain in a pressurized shirt-sleeve environment during long translations and while making contextual observations and enables rapid (less than or equal to 10 minutes) transfer to and from the surface via suit-ports. A team of field geologists provided realistic science scenarios for the simulations and served as crew members, field observers, and operators of a science backroom. Here, we present a description of the science team s operations and lessons learned.

  4. Early post-operative weight loss after laparoscopic sleeve gastrectomy correlates with the volume of the excised stomach and not with that of the sleeve! Preliminary data from a multi-detector computed tomography-based study.

    PubMed

    Pawanindra, Lal; Vindal, Anubhav; Midha, Manoj; Nagpal, Prashant; Manchanda, Alpana; Chander, Jagdish

    2015-10-01

    Pre- and post-operative stomach volumes can be important determinants for effectiveness of laparoscopic sleeve gastrectomy (LSG) in causing weight loss. There is little existing data on the volumes of stomach preoperatively and that excised during LSG. This study was designed to evaluate the change in gastric volume after LSG using multi-detector CT and to correlate it with early post-operative weight loss. Twenty consecutive patients with BMI ≥ 40 kg/m(2) and medical comorbidities underwent LSG between October 2011 and October 2013 and were analysed prospectively. The pre-operative stomach volume was measured by MDCT done 1-3 days before the surgery. LSG was performed in the standard manner using a 36F bougie. The volume of excised stomach was measured by distending the specimen with saline. MDCT of the upper abdomen was repeated 3 months postoperatively to calculate the gastric sleeve volume. Weight loss and resolution of comorbidities were documented. The mean pre-operative weight of patients was 123.90 kg, and the mean pre-operative stomach volume on MDCT was 1,067 ml. The stomach volume on pre-operative MDCT correlated with pre-operative weight and BMI. The mean volume of the excised stomach was 859 ml when measured by distension of the specimen and 850 ml on MDCT. After 3 months post surgery, the mean volume of gastric sleeve on MDCT was 217 ml, and the mean weight of the patients was 101.22 kg. The volume of the excised stomach calculated by MDCT correlated with the weight loss achieved 3 months postoperatively. However, no correlation was seen between the gastric sleeve volume 3 months postoperatively and weight loss during this period. MDCT is a good method to measure gastric volume before and after LSG. Early post-operative weight loss (3 months) correlates well with the volume of the excised stomach but not with that of the gastric sleeve.

  5. Does a titanium sleeve reduce the frequency of pseudotumors in metal-on-metal total hip arthroplasty at 5-7years follow-up?

    PubMed

    Hjorth, M H; Egund, N; Mechlenburg, I; Gelineck, J; Jakobsen, S S; Soballe, K; Stilling, M

    2016-12-01

    Little is known about pseudotumor frequency and risk factors for pseudotumor formation among different types of metal-on-metal (MoM) hip arthroplasties. A lower release of chromium and cobalt have been reported in MoM hip arthroplasties with a titanium sleeve compared to MoM designs without a titanium sleeve, but yet it is unknown whether a titanium sleeve reduces the pseudotumor frequency. We conducted a cross-sectional study to investigate: 1) pseudotumor frequency, 2) risk factors of pseudotumor formation 3) and correlations between pseudotumors, serum metal-ions, implant position, and clinical symptoms. We expected a lower pseudotumor frequency in MoM hip articulation with a titanium sleeve than reported in MoM hip articulation designs using chromium-cobalt sleeve. A consecutive series of 41 patients/49 hips (31 males), mean age 52 (28-68) years, participated in a 5.5±0.5 (4-6.5) year follow-up study of their M2a_Magnum hip articulation (Biomet Inc., Warsaw, Indiana, USA). Patients were evaluated with magnetic resonance imaging (MRI), measurements of serum metal-ions, plain radiographs, and clinical outcome measures of Harris Hip Score (HHS) and Oxford Hip Score (OHS). Eighteen of 47 hips (38%) had MRI-verified pseudotumors, all cystic, with a mean dimension of 10.6×25.6×41mm. Digital measurements on plain radiographs revealed a higher cup anteversion in patients with a pseudotumor of mean 28.4°±5.05° compared to mean 23.5°±6.5° in patients without a pseudotumor (P=0.009). Serum metal-ion concentrations, acetabular cup inclination and measures of HHS and OHS were similar between patients with and without a pseudotumor (P>0.46). At 5.5±0.5years after surgery, MRI-verified cystic pseudotumors were frequently observed in M2a_Magnum hip articulations despite the use of titanium sleeves. The pseudotumors were related to high cup anteversion angles but not related to high serum metal-ions or clinical symptoms. IV: cross-sectional study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Bronchial and arterial sleeve resection for centrally-located lung cancers

    PubMed Central

    D’Andrilli, Antonio; Venuta, Federico; Rendina, Erino Angelo

    2016-01-01

    The use of bronchial and arterial sleeve resections for the treatment of centrally-located lung cancers, when available, has become the option of choice in comparison with pneumonectomy (PN). Technical expertise, in particular in vascular reconstruction, and perioperative management improved over time allowing excellent short-term and long-term results. This is even truer if considering literature data from the main experiences published in the last years. These evidences have given to such lung sparing reconstructive procedures more and more acceptance among the surgical community. This article focuses on the main technical aspects and literature data regarding bronchovascular sleeve resections. PMID:27942409

  7. Study on coming out of the shaft from ceramic sleeve in terms of the residual displacement

    NASA Astrophysics Data System (ADS)

    Zhang, G. W.; Noda, N.-A.; Sano, Y.; Sakai, H.

    2018-06-01

    Ceramic roller can be used in the heating furnace conveniently because of its high temperature resistance. However, the coming out of the shaft may often happen from the ceramic sleeve under repeated load. In this paper, a two-dimensional shrink fitted structure is considered by replacing the shaft with the inner plate and by replacing the sleeve with the outer plate. Based on the model with stopper, the FEM simulation is performed under alternate loading with certain intervals newly added. The analysis results show that the coming out failure can be explained from the residual displacement accumulation during these intervals.

  8. Application of carterpillar SMSF on ZiL 645 engine. Volume 1. Final report. Export trade information

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-11-23

    The report, written by the Southwest Research Institute and Caterpillar, Inc., was funded by the U.S. Trade and Development Agency on behalf of ZiL, a major Russian truck manufacturer. The purpose of the study was as follows: Install the Sleeve Metering Fuel System (SMFS) on the ZIL 645 NA. This would also include conversion of the MAN combustion system to a torroidal combustion system. Evaluate the cylinder head and determine if modifications are necessary, Design and test several sets of nozzles and two pistons to determine effect on smoke and fuel consumption, Obtain steady state emissions with the 'best' configurationmore » determined by smoke and specific fuel consumption and compare the results with EURO 1 standards. The scope of work did not include developing the engine to meet EURO 1 standards.« less

  9. Evaluation of Installation Time for SMASHmount by SMASHsolar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    The Department of Energy SunShot Incubator program provides early-stage assistance to help startup companies cross technological barriers to commercialization while encouraging private sector investment. The SunShot Incubator program aims to shorten the time it takes for a young business or company to develop an innovative product concept and make it commercially available, which includes product prototyping, deployment, and, potentially, manufacturing. SMASHsolar was selected as an Incubator awardee to develop a simple, snap-together, module-integrated photovoltaic (PV) mounting system in attempts to dramatically reduce the time, effort and skill needed to install rooftop solar. In support of this award, the National Renewablemore » Energy Laboratory worked with SMASHsolar to develop a procedure for evaluating the installation time required for the SMASHmount system vs. widely-available rail systems. Amongst several installations, NREL measured the following installation times, subject to the qualifications and conditions described later in this report. NREL found that the SMASHsolar SMASHmount system was installed between 15% and 37% faster than tested competing systems after one or two installations of the system.« less

  10. Inside storm window

    NASA Astrophysics Data System (ADS)

    Kaplan, J. I.

    1980-11-01

    The work effort to design, build, install, and evaluate an inside storm window (ISW) is presented. The ISW, made of two separated layers of mylar (like a thermopane window) which, when not in use can be rolled up in a shade, is described. The work effort included: development of a prototype model; the development of production facilities to turn out a small number (50) of ISW's; the production of the windows; the installation of the windows into buildings; the building of a test chamber to determine the R value of the ISW and the subsequent determination of the R value; and a survey to determine how the residents of the homes in which ISW's were installed felt about the windows.

  11. 77 FR 36146 - Airworthiness Directives; Airbus Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-18

    ... airplanes to the applicability. We are issuing this AD to prevent degradation of the electrical insulation... could cause the level sensor to heat above acceptable limits, possibly resulting in a fuel tank... connector sleeves materials fitted to the MTI units. Degradation of the electrical insulation sleeves of the...

  12. 76 FR 68671 - Airworthiness Directives; Airbus Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-07

    ... incorrect connector sleeves materials fitted to the MTI units. Degradation of the electrical insulation... condition, if not corrected, could cause the level sensor to heat above acceptable limits, possibly.... Degradation of the electrical insulation sleeves of the Low- level indication lamps on the MTI of the flight...

  13. Prototype of the novel CAMEA concept—A backend for neutron spectrometers

    NASA Astrophysics Data System (ADS)

    Markó, Márton; Groitl, Felix; Birk, Jonas Okkels; Freeman, Paul Gregory; Lefmann, Kim; Christensen, Niels Bech; Niedermayer, Christof; Jurányi, Fanni; Lass, Jakob; Hansen, Allan; Rønnow, Henrik M.

    2018-01-01

    The continuous angle multiple energy analysis concept is a backend for both time-of-flight and analyzer-based neutron spectrometers optimized for neutron spectroscopy with highly efficient mapping in the horizontal scattering plane. The design employs a series of several upward scattering analyzer arcs placed behind each other, which are set to different final energies allowing a wide angular coverage with multiple energies recorded simultaneously. For validation of the concept and the model calculations, a prototype was installed at the Swiss neutron source SINQ, Paul Scherrer Institut. The design of the prototype, alignment and calibration procedures, experimental results of background measurements, and proof-of-concept inelastic measurements on LiHoF4 and h-YMnO3 are presented here.

  14. NGEE Arctic Zero Power Warming PhenoCamera Images, Barrow, Alaska, 2016

    DOE Data Explorer

    Shawn Serbin; Andrew McMahon; Keith Lewin; Kim Ely; Alistair Rogers

    2016-11-14

    StarDot NetCam SC pheno camera images collected from the top of the Barrow, BEO Sled Shed. The camera was installed to monitor the BNL TEST group's prototype ZPW (Zero Power Warming) chambers during the growing season of 2016 (including early spring and late fall). Images were uploaded to the BNL FTP server every 10 minutes and renamed with the date and time of the image. See associated data "Zero Power Warming (ZPW) Chamber Prototype Measurements, Barrow, Alaska, 2016" http://dx.doi.org/10.5440/1343066.

  15. Application of reverse engineering in the medical industry.

    NASA Astrophysics Data System (ADS)

    Kaleev, A. A.; Kashapov, L. N.; Kashapov, N. F.; Kashapov, R. N.

    2017-09-01

    The purpose of this research is to develop on the basis of existing analogs new design of ophthalmologic microsurgical tweezers by using reverse engineering techniques. Virtual model was obtained by using a three-dimensional scanning system Solutionix Rexcan 450 MP. Geomagic Studio program was used to remove defects and inaccuracies of the obtained parametric model. A prototype of the finished model was made on the installation of laser stereolithography Projet 6000. Total time of the creation was 16 hours from the reverse engineering procedure to 3D-printing of the prototype.

  16. After the Honeymoon: Living with Reality.

    ERIC Educational Resources Information Center

    Little, Robert O.; Temares, M. Lewis

    1986-01-01

    A seven-year long-range information systems plan at the University of Miami outlined 44 applications, most of which were to be installed in a database environment via prototyping with fourth-generation tools. The challenges that confront information systems managers are described. (Author/MLW)

  17. Netbook User’s Guide and Installation Manual.

    DTIC Science & Technology

    1997-01-31

    The general purpose of Netbook is to add value to the information available online, by developing a collaborative environment within which that...information can be effectively accessed, stored, annotated, and structured. Netbook is a prototype tool that provides users with the capacity for

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    A collection of quarterly and monthly reports from Elcam, Inc., covering progress made from January 1, 1978, through September 30, 1978, is presented. Elcam, is developing two solar-heated hot water prototype systems and two heat exchangers. This effort consists of development, manufacture, installation, maintenance, problem resolution, and system evaluation.

  19. "Grinding" cavities in polyurethane foam

    NASA Technical Reports Server (NTRS)

    Brower, J. R.; Davey, R. E.; Dixon, W. F.; Robb, P. H.; Zebus, P. P.

    1980-01-01

    Grinding tool installed on conventional milling machine cuts precise cavities in foam blocks. Method is well suited for prototype or midsize production runs and can be adapted to computer control for mass production. Method saves time and materials compared to bonding or hot wire techniques.

  20. Effect of brace design on patients with ACL-ruptures.

    PubMed

    Strutzenberger, G; Braig, M; Sell, S; Boes, K; Schwameder, H

    2012-11-01

    Different designs of functional knee braces for ACL-injury rehabilitation exist. In addition to the mechanical stabilization provided by rigid shell braces, sleeve braces also address proprioceptive mechanisms, but little is known if this leads to benefits for ACL-deficient subjects. Therefore the aim of this study was to investigate the effect of 2 different functional brace designs (shell and sleeve brace) on functional achievements in ACL-deficient patients. 28 subjects with ACL-ruptured knees performed tests for knee joint laxity, joint position sense, static and dynamic balance and isometric and dynamic lower limb extension strength in non-braced, sleeve braced and shell braced condition. The results showed a significant decrease in knee joint laxity for sleeve (33%; p<0.001) and rigid shell bracing (14%, p=0.039). The sleeve brace revealed a significant increase in dynamic balance after perturbation (20%; p=0.024) and a significant increase in dynamic lower limb peak rate of force development (17%; p=0.015) compared to the non-braced condition. The effects might be caused by the flexible area of support and the incorporated mechanisms to address proprioceptive aspects. Braces might not be needed in simple daily life tasks, but could provide beneficial support in more dynamic settings when patients return to sporting activities after an ACL-injury. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Composting municipal biosolids in polyethylene sleeves with forced aeration: Process control, air emissions, sanitary and agronomic aspects.

    PubMed

    Avidov, R; Saadi, I; Krassnovsky, A; Hanan, A; Medina, Sh; Raviv, M; Chen, Y; Laor, Y

    2017-09-01

    Composting in polyethylene sleeves with forced aeration may minimize odor emissions, vectors attraction and leachates associated with open windrows. A disadvantage of this technology is the lack of mixing during composting, potentially leading to non-uniform products. In two pilot experiments using biosolids and green waste (1:1; v:v), thermophilic conditions (>45°C) were maintained for two months, with successful control of oxygen levels and sufficient moisture. Emitted odors declined from 1.5-3.8×10 5 to 5.9×10 3 -2.3×10 4 odor units m -3 -air in the first 3weeks of the process, emphasizing the need of odor control primarily during this period. Therefore, composting might be managed in two phases: (i) a closed sleeve for 6-8weeks during which the odor is treated; (ii) an open pile (odor control is not necessary). Reduction of salmonella, E. coli and coliforms was effective initially, meeting the standards of "Class A" biosolids; however, total and fecal coliforms density increased after opening the second sleeve and exceeded the standard of 1000 most probable number (MPN) per g dry matter. Compost maturity was achieved in the open piles following the two sleeves and the final compost was non-phytotoxic and beneficial as a soil additive. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Self-actuating and locking control for nuclear reactor

    DOEpatents

    Chung, Dong K.

    1982-01-01

    A self-actuating, self-locking flow cutoff valve particularly suited for use in a nuclear reactor of the type which utilizes a plurality of fluid support neutron absorber elements to provide for the safe shutdown of the reactor. The valve comprises a substantially vertical elongated housing and an aperture plate located in the housing for the flow of fluid therethrough, a substantially vertical elongated nozzle member located in the housing and affixed to the housing with an opening in the bottom for receiving fluid and apertures adjacent a top end for discharging fluid. The nozzle further includes two sealing means, one located above and the other below the apertures. Also located in the housing and having walls surrounding the nozzle is a flow cutoff sleeve having a fluid opening adjacent an upper end of the sleeve, the sleeve being moveable between an upper open position wherein the nozzle apertures are substantially unobstructed and a closed position wherein the sleeve and nozzle sealing surfaces are mated such that the flow of fluid through the apertures is obstructed. It is a particular feature of the present invention that the valve further includes a means for utilizing any increase in fluid pressure to maintain the cutoff sleeve in a closed position. It is another feature of the invention that there is provided a means for automatically closing the valve whenever the flow of fluid drops below a predetermined level.

  3. Gastroesophageal Reflux Management with the LINX® System for Gastroesophageal Reflux Disease Following Laparoscopic Sleeve Gastrectomy.

    PubMed

    Desart, Kenneth; Rossidis, Georgios; Michel, Michael; Lux, Tamara; Ben-David, Kfir

    2015-10-01

    Laparoscopic sleeve gastrectomy (LSG) has gained significant popularity in the USA, and consequently resulted in patients experiencing new-onset gastroesophageal reflux disease (GERD) following this bariatric procedure. Patients with GERD refractory to medical therapy present a more challenging situation limiting the surgical options to further treat the de novo GERD symptoms since the gastric fundus to perform a fundoplication is no longer an option. The aim of this study is to determine if the LINX® magnetic sphincter augmentation system is a safe and effective option for patients with new gastroesophageal reflux disease following laparoscopic sleeve gastrectomy. This study was conducted at the University Medical Center. This is a retrospective review of seven consecutive patients who had a laparoscopic LINX® magnetic sphincter device placement for patients with refractory gastroesophageal reflux disease after laparoscopic sleeve gastrectomy between July 2014 and April 2015. All patients were noted to have self-reported greatly improved gastroesophageal reflux symptoms 2-4 weeks after their procedure. They were all noted to have statistically significant improved severity and frequency of their reflux, regurgitation, epigastric pain, sensation of fullness, dysphagia, and cough symptoms in their postoperative GERD symptoms compared with their preoperative evaluation. This is the first reported pilot case series, illustrating that the LINX® device is a safe and effective option in patients with de novo refractory gastroesophageal reflux disease after a laparoscopic sleeve gastrectomy despite appropriate weight loss.

  4. Endoscopic sleeve gastroplasty (the Apollo method): a new approach to obesity management.

    PubMed

    López-Nava Breviere, Gontrand; Bautista-Castaño, Inmaculada; Fernández-Corbelle, Juan Pedro; Trell, Marta

    2016-04-01

    Many obese patients cannot lose weight or reject conventional obesity management. Endoscopic sleeve gastroplasty (the Apollo method) is a pioneering coadjuvant, interventionist technique for the integral management of obesity. The goals of this study were to report safety and efficacy results obtained at 6 months in patients undergoing endoscopic sleeve gastroplasty. A prospective study was performed in 55 patients (13 males, 42 females) who were subjected to the Apollo technique; mean age was 43.5 years (range 25-60) and mean BMI was 37.7 kg/m2 (range 30-48). All received multidisciplinary follow-up for weight loss. Weight changes and presence of complications were assessed. Through the endoscope a triangular pattern suture is performed consisting of approximately 3-6 transmural (mucosa to serosa) stitches, using a cinch device to bring them nearer and form a plication. A total of 6-8 plications are used to provide a tubular or sleeve-shaped restriction to the gastric cavity. No major complications developed and patients were discharged at 24 hours following the procedure. Endoscopic and radiographic follow-up at 6 months post-procedure showed a well preserved tubular form to the stomach. After 6 months patients had lost 18.9 kg and 55.3% of excess weight. Endoscopic sleeve gastroplasty, together with dietary and psycho-behavioral changes, is a safe, effective technique in the coadjuvant management of obese patients.

  5. Characterization of the ELIMED prototype permanent magnet quadrupole system

    NASA Astrophysics Data System (ADS)

    Russo, A. D.; Schillaci, F.; Pommarel, L.; Romano, F.; Amato, A.; Amico, A. G.; Calanna, A.; Cirrone, G. A. P.; Costa, M.; Cuttone, G.; Amato, C.; De Luca, G.; Flacco, F. A.; Gallo, G.; Giove, D.; Grmek, A.; La Rosa, G.; Leanza, R.; Maggiore, M.; Malka, V.; Milluzzo, G.; Petringa, G.; Pipek, J.; Scuderi, V.; Vauzour, B.; Zappalà, E.

    2017-01-01

    The system described in this work is meant to be a prototype of a more performing one that will be installed at ELI-Beamlines in Prague for the collection of ions produced after the interaction Laser-target, [1]. It has been realized by the researchers of INFN-LNS (Laboratori Nazionali del Sud of the Instituto Nazionale di Fisica Nucleare) and SIGMAPHI, a French company, using a system of Permanent Magnet Quadrupoles (PMQs), [2]. The final system that will be installed in Prague is designed for protons and carbons up to 60 MeV/u, around 10 times more than the energies involved in the present work. The prototype, shown in this work, has been tested in collaboration with the SAPHIR experimental facility group at LOA (Laboratoire d'Optique Appliqueé) in Paris using a 200 TW Ti:Sapphire laser system. The purpose of this work is to validate the design and the performances of this large and compact bore system and to characterize the beam produced after the interaction laser-target and its features. Moreover, the optics simulations have been compared with a real beam shape on a GAFChromic film. The procedure used during the experimental campaign and the most relevant results are reported here demonstrating a good agreement with the simulations and a good control on the beam optics.

  6. 75 FR 12667 - Airworthiness Directives; Learjet Inc. Model 45 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-17

    ... certain Model 45 airplanes. This AD requires a general visual inspection for cracked and missing ballscrew... sleeve or flap actuator for cracks, and replacement or modification of the flap actuator if necessary. This AD results from reports of cracked and missing ballscrew assembly sleeves of the flap actuators...

  7. Section Work--Sleeves; Apparel Manufacturing: 9377.08.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    This course involves practice in a sleeve-making techniques. Prior to entry in this course the vocational student will have completed "Section Work--Pocket Setting." Upon completion of the course the student will be able to understand the underlying principles of sewing individual sections of garments using factory techniques comparable…

  8. 75 FR 77790 - Airworthiness Directives; The Boeing Company Model 767 Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-14

    ... repetitive inspections to detect discrepancies of the wiring and surrounding Teflon sleeves of the fuel tank... airplanes; and repair or replacement of the wiring and sleeves with new parts, as necessary. This proposed...).) That AD requires repetitive inspections to detect discrepancies of the wiring and surrounding Teflon...

  9. Moving body velocity arresting line. [stainless steel cables with energy absorbing sleeves

    NASA Technical Reports Server (NTRS)

    Hull, R. A. (Inventor)

    1981-01-01

    The arresting of a moving body is improved through the use of steel cables that elongate to absorb the kinetic energy of the body. A sleeve surrounds the cables, protecting them from chafing and providing a failsafe energy absorbing system should the cables fail.

  10. Papago Indians Light the Way.

    ERIC Educational Resources Information Center

    D'Alessandro, Bill

    1979-01-01

    Describes the world's only solar electric village power system, a photovoltaic conversion installation in a remote Papago Indian Reservation village. Notes comparative costs, electric output, and potential applications of the system, a prototype for remote rural communities and developing nations. Notes outstanding questions and key issues in…

  11. Study and development of an air conditioning system operating on a magnetic heat pump cycle (design and testing of flow directors)

    NASA Astrophysics Data System (ADS)

    Wang, Pao-Lien

    1992-09-01

    This report describes the fabrication, design of flow director, fluid flow direction analysis and testing of flow director of a magnetic heat pump. The objectives of the project are: (1) to fabricate a demonstration magnetic heat pump prototype with flow directors installed; and (2) analysis and testing of flow director and to make sure working fluid loops flow through correct directions with minor mixing. The prototype was fabricated and tested at the Development Testing Laboratory of Kennedy Space Center. The magnetic heat pump uses rear earth metal plates rotate in and out of a magnetic field in a clear plastic housing with water flowing through the rotor plates to provide temperature lift. Obtaining the proper water flow direction has been a problem. Flow directors were installed as flow barriers between separating point of two parallel loops. Function of flow directors were proven to be excellent both analytically and experimentally.

  12. Study and development of an air conditioning system operating on a magnetic heat pump cycle (design and testing of flow directors)

    NASA Technical Reports Server (NTRS)

    Wang, Pao-Lien

    1992-01-01

    This report describes the fabrication, design of flow director, fluid flow direction analysis and testing of flow director of a magnetic heat pump. The objectives of the project are: (1) to fabricate a demonstration magnetic heat pump prototype with flow directors installed; and (2) analysis and testing of flow director and to make sure working fluid loops flow through correct directions with minor mixing. The prototype was fabricated and tested at the Development Testing Laboratory of Kennedy Space Center. The magnetic heat pump uses rear earth metal plates rotate in and out of a magnetic field in a clear plastic housing with water flowing through the rotor plates to provide temperature lift. Obtaining the proper water flow direction has been a problem. Flow directors were installed as flow barriers between separating point of two parallel loops. Function of flow directors were proven to be excellent both analytically and experimentally.

  13. Scavenging energy from human walking through a shoe-mounted piezoelectric harvester

    NASA Astrophysics Data System (ADS)

    Fan, Kangqi; Liu, Zhaohui; Liu, Haiyan; Wang, Liansong; Zhu, Yingmin; Yu, Bo

    2017-04-01

    This study presents a shoe-mounted nonlinear piezoelectric energy harvester (PEH) with intent to capture energy from human walking. The PEH consists of a piezoelectric cantilever beam magnetically coupled to a ferromagnetic ball and a crossbeam. A sleeve is included to guide the travel of the ball. Experimental measurements and theoretical simulations demonstrate that the proposed design can collect energy from diverse excitation sources with different directions produced by the foot, including vibrations, swing motions, and the compressive force. The ball and the crossbeam sense the swing motion and the compressive force, respectively, and then actuate the piezoelectric beam to function. The piezoelectric beam senses the vibration along the tibial axis and generates electricity. The proposed PEH achieves the superposition of these excitations and generates multiple peaks in voltage output within one gait cycle. The output power generated by the fabricated prototype ranges from 0.03 mW to 0.35 mW when the walking velocity varies from 2 km/h to 8 km/h.

  14. High intensity portable fluorescent light

    NASA Technical Reports Server (NTRS)

    Kendall, F. B.

    1972-01-01

    Eight high intensity portable fluorescent lights were produced. Three prototype lights were also produced, two of which were subsequently updated to the physical and operational configuration of the qualification and flight units. Positioning of lamp apertures and reflectors in these lights is such that the light is concentrated and intensified in a specific pattern rather than widely diffused. Indium amalgam control of mercury vapor pressure in the lamp gives high output at lamp ambient temperatures up to 105 C. A small amount of amalgam applied to each electrode stem helps to obtain fast warm-up. Shrinking a Teflon sleeve on the tube and potting metal caps on each end of the lamp minimizes dispersion of mercury vapor and glass particles in the event of accidental lamp breakage. Operation at 20 kHz allows the lamps to consume more power than at low frequency, thus increasing their light output and raising their efficiency. When used to expose color photographic film, light from the lamps produces results approximately equal to sunlight.

  15. Lightweight Low Force Rotary Percussive Coring Tool for Planetary Applications

    NASA Technical Reports Server (NTRS)

    Hironaka, Ross; Stanley, Scott

    2010-01-01

    A prototype low-force rotary-percussive rock coring tool for use in acquiring samples for geological surveys in future planetary missions was developed. The coring tool could eventually enable a lightweight robotic system to operate from a relatively small (less than 200 kg) mobile or fixed platform to acquire and cache Mars or other planetary rock samples for eventual return to Earth for analysis. To gain insight needed to design an integrated coring tool, the coring ability of commercially available coring bits was evaluated for effectiveness of varying key parameters: weight-on-bit, rotation speed, percussive rate and force. Trade studies were performed for different methods of breaking a core at its base and for retaining the core in a sleeve to facilitate sample transfer. This led to a custom coring tool design which incorporated coring, core breakage, core retention, and core extraction functions. The coring tool was tested on several types of rock and demonstrated the overall feasibility of this approach for robotic rock sample acquisition.

  16. Digital single-channel seismic-reflection data from western Santa Monica basin

    USGS Publications Warehouse

    Normark, William R.; Piper, David J.W.; Sliter, Ray W.; Triezenberg, Peter; Gutmacher, Christina E.

    2006-01-01

    During a collaborative project in 1992, Geological Survey of Canada and United States Geological Survey scientists obtained about 850 line-km of high-quality single-channel boomer and sleeve-gun seismic-reflection profiles across Hueneme, Mugu and Dume submarine fans, Santa Monica Basin, off southern California. The goals of this work were to better understand the processes that lead to the formation of sandy submarine fans and the role of sea-level changes in controlling fan development. This report includes a trackline map of the area surveyed, as well as images of the sleeve-gun profiles and the opportunity to download both images and digital data files (SEG-Y) of all the sleeve-gun profiles.

  17. Slide release mechanism. [for space shuttle orbiter/external tank connection device

    NASA Technical Reports Server (NTRS)

    Bunker, J. W.; Ritchie, R. S. (Inventor)

    1985-01-01

    A releasable support device is described which is comprised of a hollow body with a sleeve extending transversely there-through for receiving the end of a support shank. A slider-latch, optionally lubricated, extends through side recesses in the sleeve to straddle the shank, respectively, in latched and released positions. The slider-latch is slid from its latched to its unlatched position by a pressure squib whereupon a spring or other pressure means pushes the shank out of the sleeve. At the same time, a follower element is lodged in and closed the hole in the body wall from which the shank was discharged. The mechanism was designed for the shuttle orbiter/external tank connection device.

  18. Retention sleeve for a thermal medium carrying tube in a gas turbine

    DOEpatents

    Lathrop, Norman Douglas; Czachor, Robert Paul

    2003-01-01

    Multiple tubes are connected to steam supply and spent cooling steam return manifolds for supplying cooling steam to buckets and returning spent cooling steam from the buckets to the manifolds, respectively. The tubes are prevented from axial movement in one direction by flanges engaging end faces of the spacer between the first and second-stage wheels. Retention sleeves are disposed about cantilevered ends of the tubes. One end of the retention sleeve engages an enlarged flange on the tube, while an opposite end is spaced axially from an end face of the adjoining wheel, forming a gap, enabling thermal expansion of the tubes and limiting axial displacement of the tube in the opposite direction.

  19. Composite pipe to metal joint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leslie, James C.; Leslie, II, James C.; Heard, James

    A method for making a metal to composite tube joint including selecting an elongated interior fitting constructed with an exterior barrel, reduced in exterior diameter to form a distally facing annular shoulder and then projecting still further distally to form an interior sleeve having a radially outwardly facing bonding surface. Selecting an elongated metal outer sleeve formed proximally with a collar constructed for receipt over the barrel and increased in interior diameter and projecting distally to form an exterior sleeve having a radially inwardly facing bonding surface cooperating with the first bonding surface to form an annulus receiving an extremitymore » of a composite tube and a bond bonding the extremity of the tube to the bonding surfaces.« less

  20. Automated meteorological data from commercial aircraft via satellite: Present experience and future implications

    NASA Technical Reports Server (NTRS)

    Steinberg, R.

    1978-01-01

    A low-cost communications system to provide meteorological data from commercial aircraft, in neat real-time, on a fully automated basis has been developed. The complete system including the low profile antenna and all installation hardware weighs 34 kg. The prototype system was installed on a B-747 aircraft and provided meteorological data (wind angle and velocity, temperature, altitude and position as a function of time) on a fully automated basis. The results were exceptional. This concept is expected to have important implications for operational meteorology and airline route forecasting.

  1. Protection of tree seedlings from deer browsing

    Treesearch

    Jeffrey S. Ward; George R. Stephens

    1995-01-01

    Browsing by large deer herds has seriously impaired successful regeneration on some Connecticut forests. Six plots were established in 1990 to examine the effectiveness of 5 deer browsing protection devices for 5 tree species. Protective devices included plastic mesh sleeves (60-cm), Reemay (spunbonded polypropylene) sleeves (60-cm), Tubex tree shelters (120 and 180-cm...

  2. Seismic Stability Evaluation of Alben Barkley Lock and Dam Project. Volume 3. Field and Laboratory Investigations

    DTIC Science & Technology

    1989-03-01

    the embayment indicating extensive inundation by the sea during these epochs. Some Oligocene and Miocene deposits can be found in the southern part of...accurately measure sleeve fric- tion in low-strength materials without careful calibration and equipment warm -up. The tension cone measures sleeve

  3. Hydraulic servo control spool valve

    DOEpatents

    Miller, Donald M.

    1983-01-01

    A servo operated spool valve having a fixed sleeve and axially movable spool. The sleeve is machined in two halves to form a long, narrow tapered orifice slot across which a transverse wall of the spool is positioned. The axial position of the spool wall along the slot regulates the open orifice area with extreme precision.

  4. Improved material-bagging device

    DOEpatents

    Wach, C.G.; Nelson, R.E.; Brak, S.B.

    1982-01-19

    A bagging device for transferring material; specifically contaminated material, from one chamber through an opening in a wall to a second chamber includes a cylindrical housing communicating with the opening and defining a passage between the chambers. A cylindrical cartridge is slidably received within the housing. The cartridge has a substantially rigid cylindrical sleeve to which is affixed a pliable tube. The pliable tube is positioned concentrically about the sleeve and has a pleated portion capable of unfolding from the sleeve and a closed end extending over a terminal end of the sleeve. Sealing means are interposed in sealed relationship between the cartridge and the housing. Material from one chamber is inserted into the cartridge secured in the housing and received in the closed end of the tube which unfolds into the other chamber enclosing the material therein. The tube may then be sealed behind the material and then severed to form a bag-like enclosure defined by the tube's closed terminal end and the new seal. The new seal then forms a terminal end for the unsevered portion of the pliable tube into which additional material may be placed and the bagging process repeated.

  5. Material bagging device

    DOEpatents

    Wach, Charles G.; Nelson, Robert E.; Brak, Stephen B.

    1984-01-01

    A bagging device for transferring material from one chamber through an opening in a wall to a second chamber includes a cylindrical housing communicating with the opening and defining a passage between the chambers. A cylindrical cartridge is slidably received within the housing. The cartridge has a substantially rigid cylindrical sleeve to which is affixed a pliable tube. The pliable tube is positioned concentrically about the sleeve and has a pleated portion capable of unfolding from the sleeve and a closed end extending over a terminal end of the sleeve. Sealing means are interposed in sealed relationship between the cartridge and the housing. Material from one chamber is inserted into the cartridge secured in the housing and received in the closed end of the tube which unfolds into the other chamber enclosing the material therein. The tube may then be sealed behind the material and then severed to form a bag-like enclosure defined by the tube's closed terminal end and the new seal. The new seal then forms a terminal end for the unsevered portion of the pliable tube into which additional material may be placed and the bagging process repeated.

  6. Nozzle cavity impingement/area reduction insert

    DOEpatents

    Yu, Yufeng Phillip; Itzel, Gary Michael; Osgood, Sarah Jane

    2002-01-01

    A turbine vane segment is provided that has inner and outer walls spaced from one another, a vane extending between the inner and outer walls and having leading and trailing edges and pressure and suction sides, the vane including discrete leading edge, intermediate, aft and trailing edge cavities between the leading and trailing edges and extending lengthwise of the vane for flowing a cooling medium; and an insert sleeve within at least one of the cavities and spaced from interior wall surfaces thereof. The insert sleeve has an inlet for flowing the cooling medium into the insert sleeve and has impingement holes defined in first and second walls thereof that respectively face the pressure and suction sides of the vane. The impingement holes of at least one of those first and second walls are defined along substantially only a first, upstream portion thereof, whereby the cooling flow is predominantly impingement cooling along a first region of the insert wall corresponding to the first, upstream portion and the cooling flow is predominantly convective cooling along a second region corresponding to a second, downstream portion of the at least one wall of the insert sleeve.

  7. Development and clinical application of a length-adjustable water phantom for total body irradiation.

    PubMed

    Chen, Zhi-Wei; Yao, Sheng-Yu; Zhang, Tie-Ning; Zhu, Zhen-Hua; Hu, Zhe-Kai; Lu, Xun

    2012-08-01

    A new type of water phantom which would be specialised for the absorbed dose measurement in total body irradiation (TBI) treatment is developed. Ten millimetres of thick Plexiglas plates were arranged to form a square cube with 300 mm of edge length. An appropriate sleeve-type piston was installed on the side wall, and a tabular Plexiglas piston was positioned inside the sleeve. By pushing and pulling the piston, the length of the self-made water phantom could be varied to meet the required patients' physical sizes. To compare the international standard water phantom with the length-adjustable and the Plexiglas phantoms, absorbed dose for 6-MV X ray was measured by an ionisation chamber at different depths in three kinds of phantoms. In 70 cases with TBI, midplane doses were metered using the length-adjustable and the Plexiglas phantoms for simulating human dimensions, and dose validation was synchronously carried out. There were no significant statistical differences, p > 0.05, through statistical processing of data from the international standard water phantom and the self-designed one. There were significant statistical differences, p < 0.05, between the two sets of data from the standard and the Plexiglas one. In addition, the absolute difference had a positive correlation with the varied depth of the detector in the Plexiglas phantom. Comparing the data of clinical treatment, the differences were all <1 % among the prescription doses and the validation data collected from the self-design water phantom. However, the differences collected from the Plexiglas phantom were increasing gradually from +0.77 to +2.30 % along with increasing body width. Obviously, the difference had a positive correlation with the body width. The results proved that the new length-adjustable water phantom is more accurate for simulating human dimensions than Plexiglas phantom.

  8. Segmented instrumentation tube including a locking sleeve for interlocking the segments of the instrumentation tube

    DOEpatents

    Obermeyer, F.D.

    1993-11-16

    Segmented instrumentation tube including a locking sleeve for interlocking the segments of the instrumentation tube, so that the threaded ends of the instrumentation tube do not unthread when subjected to vibration, such an instrumentation tube being suitable for use in a nuclear reactor pressure vessel. The instrumentation tube has a first member having a threaded end portion that has a plurality of first holes circumferentially around the outside surface thereof. The instrumentation tube also has a second member having a threaded end portion that has a plurality of second holes circumferentially around the outside surface thereof. The threads of the second member are caused to threadably engage the threads of the first member for defining a threaded joint there between. A sleeve having an inside surface surrounds the end portion of the first member and the end portion of the second member and thus surrounds the threaded joint. The sleeve includes a plurality of first projections and second projections that outwardly extend from the inside surface to engage the first holes and the second holes, respectively. The outside surface of the sleeve is crimped or swaged at the locations of the first projections and second projections such that the first projections and the second projections engage their respective holes. In this manner, independent rotation of the first member with respect to the second member is prevented, so that the instrumentation tube will not unthread at its threaded joint. 10 figures.

  9. Segmented instrumentation tube including a locking sleeve for interlocking the segments of the instrumentation tube

    DOEpatents

    Obermeyer, Franklin D.

    1993-01-01

    Segmented instrumentation tube including a locking sleeve for interlocking the segments of the instrumentation tube, so that the threaded ends of the instrumentation tube do not unthread when subjected to vibration, such an instrumentation tube being suitable for use in a nuclear reactor pressure vessel. The instrumentation tube has a first member having a threaded end portion that has a plurality of first holes circumferentially around the outside surface thereof. The instrumentation tube also has a second member having a threaded end portion that has a plurality of second holes circumferentially around the outside surface thereof. The threads of the second member are caused to threadably engage the threads of the first member for defining a threaded joint therebetween. A sleeve having an inside surface surrounds the end portion of the first member and the end portion of the second member and thus surrounds the threaded joint. The sleeve includes a plurality of first projections and second projections that outwardly extend from the inside surface to engage the first holes and the second holes, respectively. The outside surface of the sleeve is crimped or swaged at the locations of the first projections and second projections such that the first projections and the second projections engage their respective holes. In this manner, independent rotation of the first member with respect to the second member is prevented, so that the instrumentation tube will not unthread at its threaded joint.

  10. Patellar Sleeve Fracture With Ossification of the Patellar Tendon.

    PubMed

    Damrow, Derek S; Van Valin, Scott E

    2017-03-01

    Patellar sleeve fractures make up greater than 50% of all patellar fractures. They are essentially only seen in the pediatric population because of the thick periosteum and the distal patellar pole apophysis in this group. These fractures can lead to complications if not treated appropriately and in a timely fashion. Complications of missed or untreated patellar sleeve fractures include patella alta, anterior knee pain, and quadriceps atrophy. These can all result in severe limitations in activity. The authors describe a case of a 16-year-old boy who sustained a patellar sleeve fracture 3 years prior to presentation. On presentation, he had patella alta, diminished strength, 5° of extensor lag, and radiographs that revealed bone formation along the patellar tendon. Despite this, he was able to maintain a high level of activity. This case report explores how the patient could have maintained a high level of activity despite having a patellar sleeve fracture. Also, because of the delayed presentation, the patella was ossified and the quadriceps was retracted, which led to a novel approach to reconstructing his distal extensor mechanism. This approach included a V-Y advancement of the quadriceps tendon and patellar tendon reconstruction using the patient's hamstring tendon (semitendinosus). This technique, combined with physical therapy postoperatively, resulted in his return to varsity high school soccer. To the best of the authors' knowledge, this technique has not been reported for this rare condition. [Orthopedics. 2017; 40(2):e357-e359.]. Copyright 2016, SLACK Incorporated.

  11. Microclimatic Variation Within Sleeve Cages Used in Ecological Studies

    PubMed Central

    Nelson, Lori A.; Rieske, Lynne K.

    2014-01-01

    Abstract Sleeve cages for enclosing or excluding arthropods are essential components of field studies evaluating trophic interactions. Microclimatic variation in sleeve cages was evaluated to characterize its potential effects on subsequent long-term experiments. Two sleeve cage materials, polyester and nylon, and two cage sizes, 400 and 6000 cm 2 , were tested on eastern hemlock, Tsuga canadensis (L.) Carrière. Temperature and relative humidity inside and outside cages, and the cost and durability of the cage materials, were compared. Long-term effects of the sleeve cages were observed by measuring new growth on T. canadensis branches. The ultimate goal was to identify a material that minimizes bag-induced microclimatic variation. Bagged branches whose microclimates mimic those of surrounding unbagged branches should have minimal effects on plant growth and may prove ideal venues for assessing herbivore and predator behavior under natural conditions. No differences were found in temperature or humidity between caging materials. Small cages had higher average temperatures than large cages, especially in the winter, but this difference was confounded by the fact that small cages were positioned higher in trees than large cages. Differences in plant growth were detected. Eastern hemlock branches enclosed within polyester cages produced fewer new growth tips than uncaged controls. Both polyester and nylon cages reduced the length of new shoot growth relative to uncaged branches. In spite of higher costs, nylon cages were superior to polyester with respect to durability and ease of handling. PMID:25368083

  12. Monitoring techniques for high accuracy interference fit assembly processes

    NASA Astrophysics Data System (ADS)

    Liuti, A.; Vedugo, F. Rodriguez; Paone, N.; Ungaro, C.

    2016-06-01

    In the automotive industry, there are many assembly processes that require a high geometric accuracy, in the micrometer range; generally open-loop controllers cannot meet these requirements. This results in an increased defect rate and high production costs. This paper presents an experimental study of interference fit process, aimed to evaluate the aspects which have the most impact on the uncertainty in the final positioning. The press-fitting process considered, consists in a press machine operating with a piezoelectric actuator to press a plug into a sleeve. Plug and sleeve are designed and machined to obtain a known interference fit. Differential displacement and velocity measurements of the plug with respect to the sleeve are measured by a fiber optic differential laser Doppler vibrometer. Different driving signals of the piezo actuator allow to have an insight into the differences between a linear and a pulsating press action. The paper highlights how the press-fit assembly process is characterized by two main phases: the first is an elastic deformation of the plug and sleeve, which produces a reversible displacement, the second is a sliding of the plug with respect to the sleeve, which results in an irreversible displacement and finally realizes the assembly. The simultaneous measurements of the displacement and the force have permitted to define characteristic features in the signal useful to identify the start of the irreversible movement. These indicators could be used to develop a control logic in a press assembly process.

  13. Resident education in robotic-assisted vertical sleeve gastrectomy: outcomes and cost-analysis of 411 consecutive cases.

    PubMed

    Ecker, Brett L; Maduka, Richard; Ramdon, Andre; Dempsey, Daniel T; Dumon, Kristoffel R; Williams, Noel N

    2016-02-01

    Robotic technology is increasingly prevalent in bariatric surgery, yet there are national deficiencies in exposure of surgical residents to robotic techniques. The purpose of this study is to accurately characterize the perioperative outcomes of a resident teaching model using the robotic-assisted sleeve gastrectomy. University Hospital. We identified 411 consecutive patients who underwent robotic sleeve gastrectomy at our institution from a prospectively maintained administrative database. Perioperative morbidity, operative time, and supply cost of the procedure were analyzed. Mean operative time was 96.4±24.9 minutes; mean robot usage time was 63.9 minutes (range 30.0-122.0 min). Ninety-day morbidities included reoperation (0.72%), major bleeding complications (0.48%), staple line leak (0.24%), stricture (0.97%), need for blood transfusion (3.86%), surgical site infection (1.69%), deep vein thrombosis (0.48%), and pulmonary embolism (0.48%). Mortality was nil. The resident cohort achieved operative time plateaus after five consecutive cases. Subset analysis for fiscal year 2014 demonstrated significantly increased supply cost for robotic sleeve gastrectomy compared with its laparoscopic equivalent. Robotic-assisted sleeve gastrectomy can be instituted as a model for resident robotic education with rates of morbidity and operative times equivalent to historical laparoscopic controls. The robot's enhanced ergonomics and its opportunity for resident education must be weighed against its increased supply cost. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  14. Indocyanine green-enhanced fluorescence in laparoscopic sleeve gastrectomy.

    PubMed

    Frattini, Francesco; Lavazza, Matteo; Mangano, Alberto; Amico, Francesco; Rausei, Stefano; Rovera, Francesca; Boni, Luigi; Dionigi, Gianlorenzo

    2015-05-01

    The aim of this study is to present our preliminary experience with indocyanine green fluorescence (IGF) imaging in laparoscopic sleeve gastrectomy. After dissection of the greater curve sleeve, gastrectomy is performed using a linear articulated stapler. Once the stomach is resected, an indocyanine green solution is prepared and injected in a periferic vein. A laparoscopic system with a high-definition camera system connected to a laparoscope equipped with a specific filter for optimal detection of the near-infrared fluorescence was used at all times as previously reported in a paper of Boni et al. A methylene blue test is routinely performed after near-infrared fluorescence, and a routine gastrografin upper gastrointestinal study is performed on postoperative day 2. We retrospectively identified 15 patients undergoing laparoscopic sleeve gastrectomy between April and October 2014. IGF imaging was used for all patients. A regular and homogeneous perfusion was observed along the entire gastric sleeve including the esophago-gastric junction. On the contrary, the excised specimen appeared devascularized at IGF imaging as expected. Intraoperative methylene blue test was negative in all cases. The contrast swallow did not document any leak. Neither clinical leak nor other complications occurred postoperatively (minimum follow-up of 2 months). IGF is a recent development in minimally invasive surgery. In this preliminary experience, IGF results resemble to intraoperative methylene blue test and postoperative contrast swallow ones. IGF allows a real-time assessment and gives a direct image of tissue perfusion and vascularization. Moreover, IGF may be helpful to explain the exact pathogenesis of gastric leak.

  15. 3D PRINTING SUSTAINABLE BUILDING COMPONENTS FOR FAÇADES AND AS WINDOW ELEMENTS

    EPA Science Inventory

    The production of full scale working prototypes that can be installed on site and measured through observation and actual physical measurement are vital. Students will measure mechanical, structural, chemical and optical properties of the walls. Students will do temperature an...

  16. The 80 megawatt wind power project at Kahuku Point, Hawaii

    NASA Technical Reports Server (NTRS)

    Laessig, R. R.

    1982-01-01

    Windfarms Ltd. is developing the two largest wind energy projects in the world. Designed to produce 80 megawatts at Kahuku Point, Hawaii and 350 megawatts in Solano County, California, these projects will be the prototypes for future large-scale wind energy installations throughout the world.

  17. Prevalence of Chronic Gastritis or Helicobacter pylori Infection in Adolescent Sleeve Gastrectomy Patients Does Not Correlate with Symptoms or Surgical Outcomes.

    PubMed

    Franklin, Ashanti L; Koeck, Emily S; Hamrick, Miller C; Qureshi, Faisal G; Nadler, Evan P

    2015-08-01

    In adults undergoing gastric bypass surgery, it is routine practice to perform pre-operative testing for Helicobacter pylori infection. Evidence suggests that infection impairs anastomotic healing and contributes to complications. There currently are no data for adolescents undergoing bariatric procedures. Despite few patients with pre-operative symptoms, we noted occasional patients with H. pylori detected after sleeve gastrectomy. We reviewed our experience with our adolescent sleeve gastrectomy cohort to determine the prevalence of H. pylori infection, its predictive factors, and association with outcomes. We hypothesized that H. pylori infection would be associated with pre-operative symptoms, but not surgical outcomes. All patients undergoing sleeve gastrectomy at our hospital were included. We conducted a chart review to determine pre- or post-operative symptoms of gastroesophageal reflux disease GERD or gastritis, operative complications, and long-term anti-reflux therapy after surgery. Pathology reports were reviewed for evidence of gastritis and H. pylori infection. 78 adolescents had laparoscopic sleeve gastrectomy from January 2010 through July 2014. The prevalence of chronic gastritis was 44.9% (35/78) and 11.4% of those patients had H. pylori (4/35). Only one patient with H. pylori had pre-operative symptoms, and only 25.7% (9/35) of patients with pathology-proven gastritis had symptoms. One staple line leak occurred but this patient did not have H. pylori or gastritis. Mean patient follow-up was 10 (3-26) mos. There is a moderate prevalence of gastritis among adolescents undergoing sleeve gastrectomy, but only a small number of these patients had H. pylori infection. Neither the presence of chronic gastritis nor H. pylori infection correlated with symptoms or outcomes. Thus, in the absence of predictive symptomology or adverse outcome in those who are infected, we advocate for continued routine pathologic evaluation without the required need for pre-operative determination unless or until H. pylori infection is associated with adverse surgical outcomes.

  18. Intraoperative leak testing has no correlation with leak after laparoscopic sleeve gastrectomy.

    PubMed

    Sethi, Monica; Zagzag, Jonathan; Patel, Karan; Magrath, Melissa; Somoza, Eduardo; Parikh, Manish S; Saunders, John K; Ude-Welcome, Aku; Schwack, Bradley F; Kurian, Marina S; Fielding, George A; Ren-Fielding, Christine J

    2016-03-01

    Staple line leak is a serious complication of sleeve gastrectomy. Intraoperative methylene blue and air leak tests are routinely used to evaluate for leak; however, the utility of these tests is controversial. We hypothesize that the practice of routine intraoperative leak testing is unnecessary during sleeve gastrectomy. A retrospective cohort study was designed using a prospectively collected database of seven bariatric surgeons from two institutions. All patients who underwent sleeve gastrectomy from March 2012 to November 2014 were included. The performance of intraoperative leak testing and the type of test (air or methylene blue) were based on surgeon preference. Data obtained included BMI, demographics, comorbidity, presence of intraoperative leak test, result of test, and type of test. The primary outcome was leak rate between the leak test (LT) and no leak test (NLT) groups. SAS version 9.4 was used for univariate and multivariate analyses. A total of 1550 sleeve gastrectomies were included; most were laparoscopic (99.8%), except for one converted and two open cases. Routine intraoperative leak tests were performed in 1329 (85.7%) cases, while 221 (14.3%) did not have LTs. Of the 1329 cases with LTs, there were no positive intraoperative results. Fifteen (1%) patients developed leaks, with no difference in leak rate between the LT and NLT groups (1 vs. 1%, p = 0.999). After adjusting for baseline differences between the groups with a propensity analysis, the observed lack of association between leak and intraoperative leak test remained. In this cohort, leaks presented at a mean of 17.3 days postoperatively (range 1-67 days). Two patients with staple line leaks underwent repeat intraoperative leak testing at leak presentation, and the tests remained negative. Intraoperative leak testing has no correlation with leak due to laparoscopic sleeve gastrectomy and is not predictive of the later development of staple line leak.

  19. Effects of knee sleeves on coordination of lower-limb segments in healthy adults during level walking and one-leg hopping

    PubMed Central

    Chang, Yunhee; Jeong, Bora; Kang, Sungjae; Ryu, Jeicheong; Kim, Gyoosuk

    2017-01-01

    The evaluation of multisegment coordination is important in gaining a better understanding of the gait and physical activities in humans. Therefore, this study aims to verify whether the use of knee sleeves affects the coordination of lower-limb segments during level walking and one-leg hopping. Eleven healthy male adults participated in this study. They were asked to walk 10 m on a level ground and perform one-leg hops with and without a knee sleeve. The segment angles and the response velocities of the thigh, shank, and foot were measured and calculated by using a motion analysis system. The phases between the segment angle and the velocity were then calculated. Moreover, the continuous relative phase (CRP) was calculated as the phase of the distal segment subtracted from the phase of the proximal segment and denoted as CRPTS (thigh–shank), CRPSF (shank–foot), and CRPTF (thigh–foot). The root mean square (RMS) values were used to evaluate the in-phase or out-of-phase states, while the standard deviation (SD) values were utilized to evaluate the variability in the stance and swing phases during level walking and in the preflight, flight, and landing phases during one-leg hopping. The walking velocity and the flight time improved when the knee sleeve was worn (p < 0.05). The segment angles of the thigh and shank also changed when the knee sleeve was worn during level walking and one-leg hopping. The RMS values of CRPTS and CRPSF in the stance phase and the RMS values of CRPSF in the preflight and landing phases changed (p < 0.05 in all cases). Moreover, the SD values of CRPTS in the landing phase and the SD values of CRPSF in the preflight and landing phases increased (p < 0.05 in all cases). These results indicated that wearing a knee sleeve caused changes in segment kinematics and coordination. PMID:28533981

  20. 30-Day Outcomes of Revisional Bariatric Stapling Procedures: First Report Based on MBSAQIP Data Registry.

    PubMed

    El Chaar, Maher; Stoltzfus, Jill; Melitics, Maureen; Claros, Leonardo; Zeido, Ahmad

    2018-06-06

    The number of bariatric revisional cases has nearly doubled since 2011, and now comprises 13.6% of the total number of cases. The objective of this study is to evaluate the outcomes and safety of the two most common stapling revisional procedures, namely, sleeve and gastric bypass in comparison to primary stapling procedures using the MBSAQIP data registry. We reviewed all the sleeve and gastric bypass cases entered between January 1, 2015, and December 31, 2015, in the MBSAQIP data registry. We, then, identified sleeve and bypass patients who have had a previous bariatric procedure. Demographics and 30 day outcomes of all sleeve and gastric bypass patients were analyzed. We conducted within group comparisons comparing primary sleeve gastrectomy (PS) and primary gastric bypass (PB) patients to revisional sleeve (RS) and revisional gastric bypass (RB) patients, respectively. We, then, conducted group comparisons comparing RS to RB patients. The total number of patients analyzed was 141,577 (98,292 or 69% sleeve patients and 43,285 or 31% gastric bypass patients). Among the sleeve patients, 92,666 (94%) had a PS and 5626 (6%) had RS. Among the bypass patients, 39,567 (91%) had a PB and 3718 patients (9%) had RB. 30-day readmission rate of RS was significantly higher as compared to PS (4.1 vs 0.4%, p < 0.05). The incidence of at least one complication requiring reoperation or reintervention within 30 days following RS was twice as high as compared to PS (1.9 and 2% for RS vs 0.9 and 1.1% for PS respectively, p < 0.05). Length of stay and 30 day mortality rates for PS and RS were the same. 30-day readmission rate of RB as compared to PB was 8.3 vs 6.3% (p < 0.05). Also, the incidence of at least one complication requiring reoperation or reintervention following RB was 3.9 and 4%, respectively vs 2.4 and 2.7% for PB (p < 0.05). In addition, readmission rates and unplanned admission rates to the ICU were significantly higher for RB compared to RS (8.3 and 2% for RB vs 4.1 and 0.9% for RS respectively, p < 0.05). The incidence of at least one reoperation or one intervention following RB were also significantly higher compared to RS (3.9 vs 1.9% and 4 vs 2% respectively, p < 0.05). Revisional stapling procedures are safe but the rates of complications following RS and RB are twice as high compared to PS and PB. Also, RB are more likely to develop complications compared to RS.

  1. SiC-CMC-Zircaloy-4 Nuclear Fuel Cladding Performance during 4-Point Tubular Bend Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    IJ van Rooyen; WR Lloyd; TL Trowbridge

    2013-09-01

    The U.S. Department of Energy Office of Nuclear Energy (DOE NE) established the Light Water Reactor Sustainability (LWRS) program to develop technologies and other solutions to improve the reliability, sustain the safety, and extend the life of current reactors. The Advanced LWR Nuclear Fuel Development Pathway in the LWRS program encompasses strategic research focused on improving reactor core economics and safety margins through the development of an advanced fuel cladding system. Recent investigations of potential options for “accident tolerant” nuclear fuel systems point to the potential benefits of silicon carbide (SiC) cladding. One of the proposed SiC-based fuel cladding designsmore » being investigated incorporates a SiC ceramic matrix composite (CMC) as a structural material supplementing an internal Zircaloy-4 (Zr-4) liner tube, referred to as the hybrid clad design. Characterization of the advanced cladding designs will include a number of out-of-pile (nonnuclear) tests, followed by in-pile irradiation testing of the most promising designs. One of the out-of-pile characterization tests provides measurement of the mechanical properties of the cladding tube using four point bend testing. Although the material properties of the different subsystems (materials) will be determined separately, in this paper we present results of 4-point bending tests performed on fully assembled hybrid cladding tube mock-ups, an assembled Zr-4 cladding tube mock-up as a standard and initial testing results on bare SiC-CMC sleeves to assist in defining design parameters. The hybrid mock-up samples incorporated SiC-CMC sleeves fabricated with 7 polymer impregnation and pyrolysis (PIP) cycles. To provide comparative information; both 1- and 2-ply braided SiC-CMC sleeves were used in this development study. Preliminary stress simulations were performed using the BISON nuclear fuel performance code to show the stress distribution differences for varying lengths between loading points and clad configurations. The 2-ply sleeve samples show a higher bend momentum compared to those of the 1-ply sleeve samples. This is applicable to both the hybrid mock-up and bare SiC-CMC sleeve samples. Comparatively both the 1- and 2-ply hybrid mock-up samples showed a higher bend stiffness and strength compared with the standard Zr-4 mock-up sample. The characterization of the hybrid mock-up samples showed signs of distress and preliminary signs of fraying at the protective Zr-4 sleeve areas for the 1-ply SiC-CMC sleeve. In addition, the microstructure of the SiC matrix near the cracks at the region of highest compressive bending strain shows significant cracking and flaking. The 2-ply SiC-CMC sleeve samples showed a more bonded, cohesive SiC matrix structure. This cracking and fraying causes concern for increased fretting during the actual use of the design. Tomography was proven as a successful tool to identify open porosity during pre-test characterization. Although there is currently insufficient data to make conclusive statements regarding the overall merit of the hybrid cladding design, preliminary characterization of this novel design has been demonstrated.« less

  2. Using a guide template with a handpiece sleeve to locate the abutment screw position of a cement-retained implant restoration.

    PubMed

    Kang, Hye-Won; Lee, Du-Hyeong

    2015-09-01

    The existing techniques for drilling a screw access hole in cement-retained restorations are limited by inaccurate drill guidance and ineffective cooling of the drilling area. An approach for fabricating a guide template to provide screw retrievability using computer-aided design and computer-aided manufacturing (CAD/CAM) is described. A handpiece sleeve was made by 3-dimensional printing and incorporating it into a vacuum-formed template. The handpiece sleeve not only guides the head of the handpiece accurately but also enables the cooling water to reach the area of drilling directly. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Performance Comparison of Axisymmetric and Three-dimensional Hydrogen Film Coolant Injection in a 110N Hydrogen/oxygen Rocket

    NASA Technical Reports Server (NTRS)

    Arrington, Lynn A.; Reed, Brian D.

    1992-01-01

    An experimental performance comparison of two geometrically different fuel film coolant injection sleeves was conducted on a 110 N gaseous hydrogen/oxygen rocket. One sleeve had slots milled axially down the walls and the other had a smooth surface to give axisymmetric flow. The comparison was made to investigate a conclusion in an earlier study that attributed a performance underprediction to a symplifying modeling assumption of axisymmetric fuel film flow. The smooth sleeve had higher overall performance at one film coolant percentage and approximately the same or slightly better at another. The study showed that the lack of modeling of three-dimensional effects was not the cause of the performance underprediction as speculated in earlier analytical studies.

  4. The weight is over: RN first assisting techniques for laparoscopic sleeve gastrectomy.

    PubMed

    Wentzell, Joanne; Neff, Marc

    2015-08-01

    Obesity-related laparoscopic sleeve gastrectomy is a common yet technically challenging bariatric procedure that requires specialized surgical knowledge and training for OR personnel. Critical components of care include an effective preoperative assessment, positioning of the patient, and operation and maintenance of laparoscopic equipment and instrumentation. The purpose of this article is to explain the steps of laparoscopic sleeve gastrectomy and illustrate principles and surgical techniques for the RN who is first assisting during the procedure. Also provided is a perioperative nursing care plan for the patient undergoing bariatric surgery, to aid perioperative nurses in understanding the sequence of events and special considerations for this patient population. Copyright © 2015 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  5. Gastroesophageal Reflux Disease and Sleeve Gastrectomy.

    PubMed

    Melissas, John; Braghetto, Italo; Molina, Juan Carlos; Silecchia, Gianfranco; Iossa, Angelo; Iannelli, Antonio; Foletto, Mirto

    2015-12-01

    Gastroesophageal reflux disease (GERD) and/or hiatus hernia (HH) are one of the most common disorders of the upper gastrointestinal tract. Despite the positive effect of sleeve gastrectomy (SG) regarding weight loss and improvement in obesity co-morbidities, there are concerns about the development of de novo gastroesophageal reflux disease or worsening the existing GERD after this bariatric operation. Furthermore, controversy exists on the consequences of SG in lower esophageal sphincter function and about the ideal procedure when a hiatus hernia is preoperatively diagnosed or discovered during the laparoscopic SG. This review systematically investigates the incidence, the pathophysiology of GERD and/or HH in morbidly obese individuals before and after SG, and the treatment options for concomitant HH repair during laparoscopic sleeve gastrectomy.

  6. Method of making a composite tube to metal joint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leslie, James C.; Leslie, II, James C.; Heard, James

    A method for making a metal to composite tube joint including selecting an elongated interior fitting constructed with an exterior barrel, reduced in exterior diameter to form a distally facing annular shoulder and then projecting still further distally to form an interior sleeve having a radially outwardly facing bonding surface. Selecting an elongated metal outer sleeve formed proximally with a collar constructed for receipt over the barrel and increased in interior diameter and projecting distally to form an exterior sleeve having a radially inwardly facing bonding surface cooperating with the first bonding surface to form an annulus receiving an extremitymore » of a composite tube and a bond bonding the extremity of the tube to the bonding surfaces.« less

  7. Mechanical properties of Zr41.2Ti13.8Ni10Cu12.5Be22.5 bulk metallic glass with different geometric confinements

    NASA Astrophysics Data System (ADS)

    Zhang, Changqin; Zhang, Haifeng; Sun, Qilei; Liu, Kegao

    2018-03-01

    Zr41.2Ti13.8Ni10Cu12.5Be22.5 (Vit 1) bulk metallic glass with Cu sleeves at different positions was prepared by the Cu mold casting method, and the effects of different geometric confinements offered by Cu sleeves on the mechanical properties of Vit 1 were investigated. It was found that the mechanical properties were prominently influenced by different geometric confinements and the plasticity could be modified by optimizing the positions of Cu sleeves. The results revealed that shear band initiation and propagation could be efficiently intervened by changing the radial boundary restraints, which led to quite different mechanical behaviors.

  8. A comparative study of wood highway sound barriers

    Treesearch

    Stefan Grgurevich; Thomas Boothby; Harvey Manbeck; Courtney Burroughs; Stephen Cegelka; Craig Bernecker; Michael A. Ritter

    2002-01-01

    Prototype designs for wood highway sound barriers meeting the multiple criteria of structural integrity, acoustic effectiveness, durability, and potential for public acceptance have been developed. Existing installations of wood sound barriers were reviewed and measurements conducted in the field to estimate acoustic insertion losses. A complete matrix of design...

  9. Innovative Technology Reduces Power Plant Emissions - Commercialization Success

    NASA Technical Reports Server (NTRS)

    Parrish, Clyde

    2004-01-01

    Emission control system development includes: (1) Development of new oxidizer scrubber system to eliminate NOx waste and produce fertilizer (2) Technology licensed and a 1 to 3 MWatt-scale prototype installed on. power plant (3) Development of method to oxidize NO. to N02 (4) Experience gained from licensing NASA technology

  10. SUSTAINABLE WATER EXTRACTION AND DISTRIBUTION SYSTEM FOR AGRICULTURAL APPLICATIONS IN NAMAWANGA, KENYA

    EPA Science Inventory

    In order to ensure that the pumps are successful when installed for the community, working prototypes were tested, analyzed, and modified. The chief concerns of our functional analysis were the flow rate of the pump, the stability/durability of the system, total pumping head, ...

  11. Development and Sensing Properties Study of Underwater Assembled Water Depth-Inclination Sensors for a Multi-Component Mooring System, Using a Self-Contained Technique

    PubMed Central

    Wu, Wenhua; Feng, Jiaguo; Xie, Bin; Tang, Da; Yue, Qianjin; Xie, Ribin

    2016-01-01

    Prototype monitoring techniques play an important role in the safety guarantee of mooring systems in marine engineering. In general, the complexities of harsh ocean environmental conditions bring difficulties to the traditional monitoring methods of application, implementation and maintenance. Large amounts of existing mooring systems still lack valid monitoring strategies. In this paper, an underwater monitoring method which may be used to achieve the mechanical responses of a multi-point catenary mooring system, is present. A novel self-contained assembled water depth-inclination (D-I) sensor is designed and manufactured. Several advanced technologies, such as standalone, low power consumption and synchronism, are considered to satisfy the long-term implementation requirements with low cost during the design process. The design scheme of the water resistance barrel and installation clamp, which satisfies the diver installation, are also provided in the paper. An on-site test has previously been carried out on a production semisubmersible platform in the South China Sea. The prototype data analyses, including the D-I value in the time domain (including the data recorded during the mooring retraction and release process) and spectral characteristics, are presented to reveal the accuracy, feasibility and stability of the sensor in terms of fitting for the prototype monitoring of catenary mooring systems, especially for in-service aging platforms. PMID:27854357

  12. Experimental study on control performance of tuned liquid column dampers considering different excitation directions

    NASA Astrophysics Data System (ADS)

    Altunişik, Ahmet Can; Yetişken, Ali; Kahya, Volkan

    2018-03-01

    This paper gives experimental tests' results for the control performance of Tuned Liquid Column Dampers (TLCDs) installed on a prototype structure exposed to ground motions with different directions. The prototype structure designed in the laboratory consists of top and bottom plates with four columns. Finite element analyses and ambient vibration tests are first performed to extract the natural frequencies and mode shapes of the structure. Then, the damping ratio of the structure as well as the resonant frequency, head-loss coefficient, damping ratio, and water height-frequency diagram of the designed TLCD are obtained experimentally by the shaking table tests. To investigate the effect of TLCDs on the structural response, the prototype structure-TLCD coupled system is considered later, and its natural frequencies and related mode shapes are obtained numerically. The acceleration and displacement time-histories are obtained by the shaking table tests to evaluate its damping ratio. To consider different excitation directions, the measurements are repeated for the directions between 0° and 90° with 15° increment. It can be concluded from the study that TLCD causes to decrease the resonant frequency of the structure with increasing of the total mass. Damping ratio considerably increases with installing TLCD on the structure. This is more pronounced for the angles of 0°, 15°, 30° and 45°.

  13. Illuminance and luminance distributions of a prototype ambient illumination system for Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Mullican, R. C.; Hayes, B. C.

    1991-01-01

    Preliminary results of research conducted in the late 1970's indicate that perceptual qualities of an enclosure can be influenced by the distribution of illumination within the enclosure. Subjective impressions such as spaciousness, perceptual clarity, and relaxation or tenseness, among others, appear to be related to different combinations of surface luminance. A prototype indirect ambient illumination system was developed which will allow crew members to alter surface luminance distributions within an enclosed module, thus modifying perceptual cues to match crew preferences. A traditional lensed direct lighting system was compared to the prototype utilizing the full-scale mockup of Space Station Freedom developed by Marshall Space Flight Center. The direct lensed system was installed in the habitation module with the indirect prototype deployed in the U.S. laboratory module. Analysis centered on the illuminance and luminance distributions resultant from these systems and the implications of various luminaire spacing options. All test configurations were evaluated for compliance with NASA Standard 3000, Man-System Integration Standards.

  14. Bronchial and bronchovascular sleeve resection for treatment of central lung tumors.

    PubMed

    Lausberg, H F; Graeter, T P; Wendler, O; Demertzis, S; Ukena, D; Schäfers, H J

    2000-08-01

    To improve postoperative pulmonary reserve, we have employed parenchyma-sparing resections for central lung tumors irrespective of pulmonary function. The results of lobectomy, pneumonectomy, and sleeve resection were analyzed retrospectively. From October 1995 to June 1999, 422 typical lung resections were performed for lung cancer. Of these, 301 were lobectomies (group I), 81 were sleeve resections (group II), and 40 were pneumonectomies (group III). Operative mortality was 2% in group I, 1.2% in group II, and 7.5% in group III (group I and II vs. group III, p<0.03). Mean time of intubation was 1.0+/-4.1 days in group I, 0.9+/-1.3 days in group II, and 3.6+/-11.2 days in group III (groups I and II vs. group III, p<0.01). The incidence of bronchial complications was 1.3% in group I, none in group II, and 7.5% in group III (group I and II vs group III, p<0.001). After 2 years, survival was 64% in group I, 61.9% in group II, and 56.1% in group III (p = NS). Freedom from local disease recurrence was 92.1% in group I, 95.7% in group II, and 90.9% in group III after 2 years (p = NS). Sleeve resection is a useful surgical option for the treatment of central lung tumors, thus avoiding pneumonectomy with its associated risks. Morbidity, early mortality, long-term survival, and recurrence of disease after sleeve resection are similar to those seen after lobectomy.

  15. Adherence to blood pressure measurement guidelines in long-term care facilities: A cross sectional study.

    PubMed

    Ozone, Sachiko; Sato, Mikiya; Takayashiki, Ayumi; Sakamoto, Naoto; Yoshimoto, Hisashi; Maeno, Tetsuhiro

    2018-05-01

    To assess the extent to which long-term care facilities in Japan adhere to blood pressure (BP) measurement guidelines. Cross-sectional, observational survey. Japan (nationwide). Geriatric health service facilities that responded to a questionnaire among 701 facilities that provide short-time daycare rehabilitation services in Japan. A written questionnaire that asked about types of measurement devices, number of measurements used to obtain an average BP, resting time prior to measurement, and measurement methods when patients' arms were covered with thin (eg, a light shirt) or thick sleeves (eg, a sweater) was administered. Proportion of geriatric health service facilities adherent to BP measurement guidelines. The response rate was 63.2% (443/701). Appropriate upper-arm BP measurement devices were used at 302 facilities (68.2%). The number of measurements was appropriate at 7 facilities (1.6%). Pre-measurement resting time was appropriate (≥5 minutes) at 205 facilities (46.3%). Of the 302 facilities that used appropriate BP measurement devices, 4 (1.3%) measured BP on a bare arm if it was covered with a thin sleeve, while 266 (88.1%) measured BP over a thin sleeve. When arms were covered with thick sleeves, BP was measured on a bare arm at 127 facilities (42.1%) and over a sleeve at 78 facilities (25.8%). BP measurement guidelines were not necessarily followed by long-term care service facilities in Japan. Modification of guidelines regarding removing thick sweaters and assessing BP on a visit-to-visit basis might be needed.

  16. Design test request No. 1263 K Reactor graphite key and VSR channel sleeve test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kempf, F.J.

    1964-12-10

    The objectives of this test were: (1) Determine the coefficient of friction between two adjacent layers of K Reactor graphite at room temperature. (2) Determine the average load required to cause failure of an unirradiated K Reactor side reflector bar, when subjected to tensile loading applied through the reflector keys. (3) Determine the average load at failure and the average deflection at failure of a single VSR channel key when loaded in keyways with clearances equal to those used in original stack construction. (4) Determine the average load and deflection required to break the four K Reactor VSR keys whenmore » loaded simultaneously in both `3-layer` and `7-layer` mockups. Also determine the mode of key failure; i.e., shear, flexure or combined compression and bending. Following these key rupture tests, determine the strength and deflection characteristics of the proposed K Reactor VSR channel sleeve when loaded in a manner identical to that used to fracture the keys. (5) Determine the average load and deflection at failure of both the proposed K Reactor VSR channel sleeves and the proposed C Reactor sleeves when subjected to crushing loads. (6) Determine the extent of damage to the proposed K Reactor VSR channel sleeve when subjected to the following vertical rod loading conditions. (a) Full rod drop in a channel mockup which has been misaligned 2 1/2 inches. (b) Full rod drop in a channel which has been misaligned an amount equal to the maximum flexibility of a `universal` VSR.« less

  17. Loss of local capture of the pulmonary vein myocardium after antral isolation: prevalence and clinical significance.

    PubMed

    Squara, Fabien; Liuba, Ioan; Chik, William; Santangeli, Pasquale; Zado, Erica S; Callans, David J; Marchlinski, Francis E

    2015-03-01

    Capture of the myocardial sleeves of the pulmonary veins (PV) during PV pacing is mandatory for assessing exit block after PV isolation (PVI). However, previous studies reported that a significant proportion of PVs failed to demonstrate local capture after PVI. We designed this study to evaluate the prevalence and the clinical significance of loss of PV capture after PVI. Thirty patients (14 redo) undergoing antral PVI were included. Before and after PVI, local PV capture was assessed during circumferential pacing (10 mA/2 milliseconds) with a circular multipolar catheter (CMC), using EGM analysis from each dipole of the CMC and from the ablation catheter placed in ipsilateral PV. Pacing output was varied to optimize identification of sleeve capture. All PVs demonstrated sleeve capture before PVI, but only 81% and 40% after first time and redo PVI, respectively (P < 0.001 vs. before PVI). In multivariate analysis, absence of spontaneous PV depolarizations after PVI and previous PVI procedures were associated with less PV sleeve capture after PVI (40% sleeve capture, P < 0.001 for both). Loss of PV local capture by design was coincident with the development of PV entrance block and importantly predicted absence of acute reconnection during adenosine challenge with 96% positive predictive value (23% negative predictive value). Loss of PV local capture is common after antral PVI resulting in entrance block, and may be used as a specific alternate endpoint for PV electrical isolation. Additionally, loss of PV local capture may identify PVs at very low risk of acute reconnection during adenosine challenge. © 2014 Wiley Periodicals, Inc.

  18. Early Australian experience in robotic sleeve gastrectomy: a single site series.

    PubMed

    Silverman, Candice D; Ghusn, Michael A

    2017-05-01

    The use of robotic platforms in bariatric surgery has recently gained relevance. With an increased use of this technology come concerns regarding learning curve effects during the initial implementation phase. The sleeve gastrectomy though may represent an ideal training procedure for introducing the robot into bariatric surgical practice. The present review of the first 10 consecutive robotic sleeve gastrectomy procedures performed in an Australian bariatric programme by a single surgeon describes the evolution of the technique, learning curve and initial patient outcomes. Between 2014 and 2015, robotic sleeve gastrectomies were performed as primary and revisional procedures by a consistent surgeon-assistant team. Technique evolution and theatre set-up were documented. Patient demographics, operative time (robot docking and total operation time), additional operative procedures performed, operative and post-operative complications at 1, 3 and 6 months post-procedure and weight loss achieved at 6 months were retrospectively reviewed from a prospectively maintained database. Ten robotic sleeve gastrectomies were performed without significant operative complications. One patient was treated as an outpatient with oral antibiotics for a superficial wound infection. The median total operative time was 123 min (interquartile range (IQR) 108.8-142.5), with a median incision to docking time of 19 min (IQR 15.0-31.8). Length of stay in hospital was 2-3 days. Median excess weight loss achieved at 6 months was 50% (IQR 33.9-66.5). This study describes a method of safely introducing the da Vinci robot into bariatric surgical practice. © 2016 Royal Australasian College of Surgeons.

  19. Development and Testing of a Friction-Based Post-Installable Sensor for Subsea Fiber-Optic Monitoring System

    NASA Technical Reports Server (NTRS)

    Bentley, Nicole L.; Brower, David V.; Le, Suy Q.; Seaman, Calvin H.; Tang, Henry H.

    2017-01-01

    This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system that can be deployed on existing subsea structures. This paper provides a summary of the design concept, prototype development, prototype performance testing, and design refinements of the device. The results of the laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are included in this paper. Limitations of the initial design were identified and future design improvements were proposed. These new features will enhance the coupling of the device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based coupling devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on subsea structures, flowlines or risers. The work described in this paper investigates the design of a friction-based coupling device (friction clamp), which is applicable for pipelines and structures that are suspended in the water column and those that are resting on the seabed. The monitoring elements consist of fiber-optic sensors that are bonded to a metal clamshell with a high-friction coating. The friction clamp has a single hinge design to facilitate the operation of the clamp and dual rows of opposing fasteners to distribute the clamping force on the structure. The friction clamp can be installed by divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology, Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance these technologies that would benefit the environment, the public, and commercial industries.

  20. Development and Testing of a Friction-Based Post-Installable Sensor for Subsea Fiber-Optic Monitoring Systems

    NASA Technical Reports Server (NTRS)

    Bentley, Nicole; Brower, David; Le, Suy Q.; Seaman, Calvin; Tang, Henry

    2017-01-01

    This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system that can be deployed on existing subsea structures. This paper provides a summary of the design concept, prototype development, prototype performance testing, and design refinements of the device. The results of the laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are included in this paper. Limitations of the initial design were identified and future design improvements were proposed. These new features will enhance the coupling of the device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based coupling devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on subsea structures, flowlines or risers. The work described in this paper investigates the design of a friction-based coupling device (friction clamp), which is applicable for pipelines and structures that are suspended in the water column and those that are resting on the seabed. The monitoring elements consist of fiber-optic sensors that are bonded to a metal clamshell with a high-friction coating. The friction clamp has a single hinge design to facilitate the operation of the clamp and dual rows of opposing fasteners to distribute the clamping force on the structure. The friction clamp can be installed by divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology, Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance these technologies that would benefit the environment, the public, and commercial industries.

  1. Protected Nuclear Fuel Element

    DOEpatents

    Kittel, J. H.; Schumar, J. F.

    1962-12-01

    A stainless steel-clad actinide metal fuel rod for use in fast reactors is reported. In order to prevert cladding failures due to alloy formation between the actinide metal and the stainless steel, a mesh-like sleeve of expanded metal is interposed between them, the sleeve metal being of niobium, tantalum, molybdenum, tungsten, zirconium, or vanadium. Liquid alkali metal is added as a heat transfer agent. (AEC)

  2. Improved Gustatory Sensitivity in Morbidly Obese Patients After Laparoscopic Sleeve Gastrectomy.

    PubMed

    Altun, Huseyin; Hanci, Deniz; Altun, Hasan; Batman, Burcin; Serin, Rahmi Kursat; Karip, Aziz Bora; Akyuz, Umit

    2016-07-01

    The reduction in the preferences for sweet and fat containing tastes in obese patients who underwent bariatric surgery was relatively well shown; however, there are only limited data on the changes in the sensitivity of other tastes like sour, salty, and bitter. We investigated the changes in gustatory sensitivity of 52 morbidly obese patients (M/F, 22/30; age range, 19-60 years; BMI range, 32.5-63.0 kg/m(2)) after laparoscopic sleeve gastrectomy. The surgery was performed by the same surgeon using 5 ports technique. Gustatory sensitivity was tested preoperatively and 1 and 3 months after the surgery using standardized Taste Strips test. There was a statistically significant improvement in the taste acuity to sweet, sour, salty, and bitter tastants in morbidly obese patients after the laparoscopic sleeve gastrectomy during the follow-up period of 3 months. Median whole test scores of the patients were increased from 11.5 preoperatively to 14 in the first and third months. In this study, we were able to show the significant improvement in gustatory sensitivity of morbidly obese patients after laparoscopic sleeve gastrectomy for the first time in literature. © The Author(s) 2016.

  3. Shotgun cartridge rock breaker

    DOEpatents

    Ruzzi, Peter L.; Morrell, Roger J.

    1995-01-01

    A rock breaker uses shotgun cartridges or other firearm ammunition as the explosive charge at the bottom of a drilled borehole. The breaker includes a heavy steel rod or bar, a gun with a firing chamber for the ammunition which screws onto the rod, a long firing pin running through a central passage in the rod, and a firing trigger mechanism at the external end of the bar which strikes the firing pin to fire the cartridge within the borehole. A tubular sleeve surround the main body of the rod and includes slits the end to allow it to expand. The rod has a conical taper at the internal end against which the end of the sleeve expands when the sleeve is forced along the rod toward the taper by a nut threaded onto the external end of the rod. As the sleeve end expands, it pushes against the borehole and holds the explosive gasses within, and also prevents the breaker from flying out of the borehole. The trigger mechanism includes a hammer with a slot and a hole for accepting a drawbar or drawpin which, when pulled by a long cord, allows the cartridge to be fired from a remote location.

  4. An AC-electromagnetic bearing for flywheel energy storage in space

    NASA Technical Reports Server (NTRS)

    Nikolajsen, Jorgen L.

    1993-01-01

    A repulsive type AC-electromagnetic bearing was developed and tested. It was conceived on the basis of the so-called Magnetic River suspension for high-speed trains. The appearance of the bearing is similar to the traditional DC-type electromagnetic bearing but the operating principle is different. The magnets are fed with alternating current instead of direct current and the rotor is fitted with a conducting sleeve (e.g. aluminum) instead of a ferromagnetic sleeve. The repulsion is due to induction of eddy-currents in the conducting sleeve. The bearing is inherently stable and requires no feedback control. It provides support in five degrees of freedom such that a short rotor may be fully supported by a single bearing. These capabilities were demonstrated experimentally. On the down side, the load carrying capacity and the damping obtained so far were quite low compared to the DC-type bearing. Also, significant heating of the conducting sleeve was experienced. The AC-bearing is essentially a modified induction motor and there are strong indications that it can be run both as a motor and as a generator with no commutator requirements. It is therefore considered to be a good candidate for support of energy storage flywheels in space.

  5. Decoding static and dynamic arm and hand gestures from the JPL BioSleeve

    NASA Astrophysics Data System (ADS)

    Wolf, M. T.; Assad, C.; Stoica, A.; You, Kisung; Jethani, H.; Vernacchia, M. T.; Fromm, J.; Iwashita, Y.

    This paper presents methods for inferring arm and hand gestures from forearm surface electromyography (EMG) sensors and an inertial measurement unit (IMU). These sensors, together with their electronics, are packaged in an easily donned device, termed the BioSleeve, worn on the forearm. The gestures decoded from BioSleeve signals can provide natural user interface commands to computers and robots, without encumbering the users hands and without problems that hinder camera-based systems. Potential aerospace applications for this technology include gesture-based crew-autonomy interfaces, high degree of freedom robot teleoperation, and astronauts' control of power-assisted gloves during extra-vehicular activity (EVA). We have developed techniques to interpret both static (stationary) and dynamic (time-varying) gestures from the BioSleeve signals, enabling a diverse and adaptable command library. For static gestures, we achieved over 96% accuracy on 17 gestures and nearly 100% accuracy on 11 gestures, based solely on EMG signals. Nine dynamic gestures were decoded with an accuracy of 99%. This combination of wearableEMGand IMU hardware and accurate algorithms for decoding both static and dynamic gestures thus shows promise for natural user interface applications.

  6. Apparatus and method for the acceleration of projectiles to hypervelocities

    DOEpatents

    Hertzberg, Abraham; Bruckner, Adam P.; Bogdanoff, David W.

    1990-01-01

    A projectile is initially accelerated to a supersonic velocity and then injected into a launch tube filled with a gaseous propellant. The projectile outer surface and launch tube inner surface form a ramjet having a diffuser, a combustion chamber and a nozzle. A catalytic coated flame holder projecting from the projectile ignites the gaseous propellant in the combustion chamber thereby accelerating the projectile in a subsonic combustion mode zone. The projectile then enters an overdriven detonation wave launch tube zone wherein further projectile acceleration is achieved by a formed, controlled overdriven detonation wave capable of igniting the gaseous propellant in the combustion chamber. Ultrahigh velocity projectile accelerations are achieved in a launch tube layered detonation zone having an inner sleeve filled with hydrogen gas. An explosive, which is disposed in the annular zone between the inner sleeve and the launch tube, explodes responsive to an impinging shock wave emanating from the diffuser of the accelerating projectile thereby forcing the inner sleeve inward and imparting an acceleration to the projectile. For applications wherein solid or liquid high explosives are employed, the explosion thereof forces the inner sleeve inward, forming a throat behind the projectile. This throat chokes flow behind, thereby imparting an acceleration to the projectile.

  7. The CUORE cryostat and its bolometric detector

    DOE PAGES

    Santone, D.; Alduino, C.; Alfonso, K.; ...

    2017-02-16

    CUORE is a cryogenic detector that will be operated at LNGS to search for neutrinoless double beta decay (0νββ) of 130Te. The detector installation was completed in summer 2016. Before the installation, several cold runs were done to test the cryogenic system performance. In the last cold run the base temperature of 6.3 mK was reached in stable condition. CUORE-0, a CUORE prototype, has proven the feasibility of CUORE, demonstrating that the target background of 0.01 counts/keV/kg/y and the energy resolution of 5 keV are within reach.

  8. The influence of EI-21 redox ion-exchange resins on the secondary-coolant circuit water chemistry of vehicular nuclear power installations

    NASA Astrophysics Data System (ADS)

    Moskvin, L. N.; Rakov, V. T.

    2015-06-01

    The results obtained from testing the secondary-coolant circuit water chemistry of full-scale land-based prototype bench models of vehicular nuclear power installations equipped with water-cooled water-moderated and liquid-metal reactor plants are presented. The influence of copper-containing redox ionexchange resins intended for chemically deoxygenating steam condensate on the working fluid circulation loop's water chemistry is determined. The influence of redox ion-exchange resins on the water chemistry is evaluated by generalizing an array of data obtained in the course of extended monitoring using the methods relating to physicochemical analysis of the quality of condensate-feedwater path media and the methods relating to metallographic analysis of the state of a faulty steam generator's tube system surfaces. The deoxygenating effectiveness of the normal state turbine condensate vacuum deaeration system is experimentally determined. The refusal from applying redox ion-exchange resins in the condensate polishing ion-exchange filters is formulated based on the obtained data on the adverse effect of copper-containing redox ionexchange resins on the condensate-feedwater path water chemistry and based on the data testifying a sufficient effect from using the normal state turbine condensate vacuum deaeration system. Data on long-term operation of the prototype bench model of a vehicular nuclear power installation without subjecting the turbine condensate to chemical deoxygenation are presented.

  9. Establishment, test and evaluation of a prototype volcano surveillance system

    NASA Technical Reports Server (NTRS)

    Ward, P. L.; Eaton, J. P.; Endo, E.; Harlow, D.; Marquez, D.; Allen, R.

    1973-01-01

    A volcano-surveillance system utilizing 23 multilevel earthquake counters and 6 biaxial borehole tiltmeters is being installed and tested on 15 volcanoes in 4 States and 4 foreign countries. The purpose of this system is to give early warning when apparently dormant volcanoes are becoming active. The data are relayed through the ERTS-Data Collection System to Menlo Park for analysis. Installation was completed in 1972 on the volcanoes St. Augustine and Iliamna in Alaska, Kilauea in Hawaii, Baker, Rainier and St. Helens in Washington, Lassen in California, and at a site near Reykjavik, Iceland. Installation continues and should be completed in April 1973 on the volcanoes Santiaguito, Fuego, Agua and Pacaya in Guatemala, Izalco in El Salvador and San Cristobal, Telica and Cerro Negro in Nicaragua.

  10. Behavior of a nuclear steel containment equipment hatch at large strain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fanous, F.; Greimann, L.

    1988-05-01

    During a severe accident, buckling of a steel containment hatch door, large deformation and ovaling of the hatch sleeve are potential causes of mismatch at the sealing surface which can result in a leakage path. A three-dimensional nonlinear finite element analysis of a typical steel containment/sleeve/hatch assembly that includes containment stiffeners, pretensioned swing bolts, and hatch door geometric imperfection is presented. The analysis was carried out to the nonlinear range up to large strains. The results indicated that the buckling load occurs at pressure, far above that which causes gross yielding of the shell plate. Although buckling of the hatchmore » door increased the relative motions of the hatch sleeve and the hatch door, the motions remained sufficiently small to prevent leakage.« less

  11. Ducting arrangement for cooling a gas turbine structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Ching-Pang; Morrison, Jay A.

    2015-07-21

    A ducting arrangement (10) for a can annular gas turbine engine, including: a duct (12, 14) disposed between a combustor (16) and a first row of turbine blades and defining a hot gas path (30) therein, the duct (12, 14) having raised geometric features (54) incorporated into an outer surface (80); and a flow sleeve (72) defining a cooling flow path (84) between an inner surface (78) of the flow sleeve (72) and the duct outer surface (80). After a cooling fluid (86) traverses a relatively upstream raised geometric feature (90), the inner surface (78) of the flow sleeve (72)more » is effective to direct the cooling fluid (86) toward a landing (94) separating the relatively upstream raised geometric feature (90) from a relatively downstream raised geometric feature (94).« less

  12. Effect of Purine Co-Transmitters on Automatic Activity Caused by Norepinephrine in Myocardial Sleeves of Pulmonary Veins.

    PubMed

    Karimova, V M; Pustovit, K B; Abramochkin, D V; Kuz'min, V S

    2017-03-01

    We studied the effect of extracellular purine nucleotides (NAD + and ATP) on spontaneous arrhythmogenic activity caused by norepinephrine in myocardial sleeves of pulmonary veins. In pulmonary veins, NAD + and ATP reduced the frequency of action potentials and their duration at regular type of spontaneous activity caused by norepinephrine. NAD + and ATP lengthened the intervals between spike bursts at periodic (burst) type of spontaneous activity. In addition, ATP shortened the duration of spike bursts and the number of action potentials in the "bursts" caused by norepinephrine in the pulmonary veins. It was hypothesized that NAD + and ATP attenuate the effects of sympathetic stimulation and when released together with norepinephrine from sympathetic endings in vivo, probably, reduce arrhythmogenic activity in myocardial sleeves of pulmonary veins.

  13. Apparatus and method for enhancing tissue repair in mammals

    NASA Technical Reports Server (NTRS)

    Goodwin, Thomas J. (Inventor); Parker, Clayton R. (Inventor)

    2009-01-01

    An apparatus is introduced for the use of enhancing tissue repair in mammals. The apparatus includes a sleeve; an electrically conductive coil; a sleeve support; an electrical circuit configured to supply the coil with a square wave time varying electrical current sufficient to create approximately 0.05 gauss to 0.5 gauss. When in use, the sleeve of the apparatus is placed on a mammalian body part and the time varying electromagnetic force of from approximately 0.05 gauss to 0.5 gauss is generated on the mammalian body for an extended period of time so that the tissue is encouraged to be regenerated in the mammalian body part at a rate in excess of the normal tissue regeneration rate relative to regeneration without application of the time varying electromagnetic force.

  14. A compact optical fiber positioner

    NASA Astrophysics Data System (ADS)

    Hu, Hongzhuan; Wang, Jianping; Liu, Zhigang; Zhou, Zengxiang; Zhai, Chao; Chu, Jiaru

    2016-07-01

    In this paper, a compact optical fiber positioner is proposed, which is especially suitable for small scale and high density optical fiber positioning. Based on the positioning principle of double rotation, positioner's center shaft depends on planetary gear drive principle, meshing with the fixed annular gear central motor gear driving device to rotate, and the eccentric shaft rotated driving by a coaxial eccentric motor, both center and the eccentric shaft are supported by a rolling bearings; center and eccentric shaft are both designed with electrical zero as a reference point, and both of them have position-limiting capability to ensure the safety of fiber positioning; both eccentric and center shaft are designed to eliminating clearance with spring structure, and can eliminate the influence of gear gap; both eccentric and center motor and their driving circuit can be installed in the positioner's body, and a favorable heat sink have designed, the heat bring by positioning operation can be effectively transmit to design a focal plane unit through the aluminum component, on sleeve cooling spiral airway have designed, when positioning, the cooling air flow is inlet into install hole on the focal plate, the cooling air flow can effectively take away the positioning's heat, to eliminate the impact of the focus seeing. By measuring position device's sample results show that: the unit accuracy reached 0.01mm, can meet the needs of fiber positioning.

  15. Innovative Technology Reduces Power Plant Emissions-Commercialization Success

    NASA Technical Reports Server (NTRS)

    Parrish, Clyde; Chung, Landy

    2004-01-01

    Overview of emission control system development: (1) Development of new oxidizer scrubber system to eliminate NOx waste and produce fertilizer (2) Technology licensed and a 1 to 3 MWatt-scale prototype installed on power plant (3) Development of method to oxidize NO to NO2 (4) Experience gained from licensing NASA technology.

  16. Schedules, technical status, and program activities in the development of a single family solar space heating system

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A collection of three quarterly reports are given covering the development of two prototype solar heating systems consisting of the following subsystems: collector, storage, control, transport, and site data acquisition. The two systems are being installed at York, Pennsylvania, and Manchester, New Hampshire.

  17. Initial results from the Lick Observatory Laser Guide Star Adaptive Optics System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olivier, S.S.; An, J.; Avicola, K.

    1995-11-08

    A prototype adaptive optics system has been installed and tested on the 3 m Shane telescope at Lick Observatory. The adaptive optics system performance, using bright natural guide stars, is consistent with expectations based on theory. A sodium-layer laser guide star system has also been installed and tested on the Shane telescope. Operating at 15 W, the laser system produces a 9th magnitude guide star with seeing-limited size at 589 nm. Using the laser guide star, the adaptive optics system has reduced the wavefront phase variance on scales above 50 cm by a factor of 4. These results represent themore » first continuous wavefront phase correction using a sodium-layer laser guide star. Assuming tip-tilt is removed using a natural guide star, the measured control loop performance should produce images with a Strehl ratio of 0.4 at 2.2 {mu}m in 1 arc second seeing. Additional calibration procedures must be implemented in order to achieve these results with the prototype Lick adaptive optics system.« less

  18. Very high energy gamma astronomy at the South Pole

    NASA Astrophysics Data System (ADS)

    Landi, G.

    1991-07-01

    The Air Cherenkov Technique (ACT) is a very important tool to extend our present knowledge on very high energy (VHE) gamma emission from compact astrophysical sources. To overcome the intrinsic limitations of this technique, we are testing the possibility of installing an ACT Telescope at the South Pole. This site is ideal for several reasons: The long polar night permits almost continuous ovservation of a source (up to 400 hours per month and 1700 hours per year). The circumpolarity of the sky simplifies data analysis. The region of the sky is particularly rich in candidate sources. To test the effectiveness of the site, we installed a prototype telescope in the austral summer of 1989-1990. The prototype started to operate in May 1990. Bartol, Firenze, Purdue, Smithsonian, Wisconsin Collaboration. Members are: M. Pomerantz, Bartol; G. Barbagli, G. Castellini, G. Landi, M. Salvati, Firenze; J. Gaidos, F. Loeffler, G. Sembrosky, C. Wilson, G. Zirnstein, Purdue Univ.; P. Slane, A. Szentgyorgy, T.C. Weekes, Smithsonian; U. Camerini, K. Engel, M. Frankowski, W.F. Fry, F. Halzen, J. Jacobsen, M. Jaworski, A. Kenter, R. March, R. Morse, Univ. of Wisconsin

  19. Dielectric Barrier Discharge (DBD) Plasma Actuators Thrust-Measurement Methodology Incorporating New Anti-Thrust Hypothesis

    NASA Technical Reports Server (NTRS)

    Ashpis, David E.; Laun, Matthew C.

    2014-01-01

    We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a large diameter, grounded, metal sleeve.

  20. NEUTRONIC REACTORS

    DOEpatents

    Anderson, J.B.

    1960-01-01

    A reactor is described which comprises a tank, a plurality of coaxial steel sleeves in the tank, a mass of water in the tank, and wire grids in abutting relationship within a plurality of elongated parallel channels within the steel sleeves, the wire being provided with a plurality of bends in the same plane forming adjacent parallel sections between bends, and the sections of adjacent grids being normally disposed relative to each other.

  1. Friction Stir Weld Tools

    NASA Technical Reports Server (NTRS)

    Carter, Robert W. (Inventor); Payton, Lewis N. (Inventor)

    2007-01-01

    A friction stir weld tool sleeve is supported by an underlying support pin. The pin material is preferably selected for toughness and fracture characteristics. The pin sleeve preferably has a geometry which employs the use of an interrupted thread, a plurality of flutes and/or eccentric path to provide greater flow through. Paddles have been found to assist in imparting friction and directing plastic metal during the welding process.

  2. Friction stir weld tools

    NASA Technical Reports Server (NTRS)

    Carter, Robert W. (Inventor); Payton, Lewis N. (Inventor)

    2007-01-01

    A friction stir weld tool sleeve is supported by an underlying support pin. The pin material is preferably selected for toughness and fracture characteristics. The pin sleeve preferably has a geometry which employs the use of an interrupted thread, a plurality of flutes and/or eccentric path to provide greater flow through. Paddles have been found to assist in imparting friction and directing plastic metal during the welding process.

  3. Cooling air recycling for gas turbine transition duct end frame and related method

    DOEpatents

    Cromer, Robert Harold; Bechtel, William Theodore; Sutcu, Maz

    2002-01-01

    A method of cooling a transition duct end frame in a gas turbine includes the steps of a) directing cooling air into the end frame from a region external of the transition duct and the impingement cooling sleeve; and b) redirecting the cooling air from the end frame into the annulus between the transition duct and the impingement cooling sleeve.

  4. A Method to Estimate Fabric Particle Penetration Performance

    DTIC Science & Technology

    2014-09-08

    may be needed to improve the correlation between wind tunnel component sleeve tests and bench top swatch test. The ability to predict multi-layered...within the fabric/component gap may be needed to improve the correlation between wind tunnel component sleeve tests and bench top swatch test...impermeable garment . Heat stress becomes a major problem with this approach however, as normal physiological heat loss mechanisms (especially sweat

  5. LINER FOR EXTRUSION BILLET CONTAINERS

    DTIC Science & Technology

    Shrink-fit assembly device for buildup of ceramic-coated liner and sleeve assemblies was tested and modified to develop desired temperatures and...preliminary evaluation of suitability for extrusion liner use. Procedures were developed for welding short, hollow ceramic cylinders of high-strength metal...carbides and borides to form a ceramic extrusion liner of suitable length. Disassembly tooling for rapid separation of shrink-fitted sleeves from a worn

  6. Towards an operational fault isolation expert system for French telecommunication satellite Telecom 2

    NASA Astrophysics Data System (ADS)

    Haziza, M.

    1990-10-01

    The DIAMS satellite fault isolation expert system shell concept is described. The project, initiated in 1985, has led to the development of a prototype Expert System (ES) dedicated to the Telecom 1 attitude and orbit control system. The prototype ES has been installed in the Telecom 1 satellite control center and evaluated by Telecom 1 operations. The development of a fault isolation ES covering a whole spacecraft (the French telecommunication satellite Telecom 2) is currently being undertaken. Full scale industrial applications raise stringent requirements in terms of knowledge management and software development methodology. The approach used by MATRA ESPACE to face this challenge is outlined.

  7. International Infantry and Joint Services Small Arms Systems Section Symposium, Exhibition and Firing Demonstration. Held in Atlantic City, NJ on 13-16 May 2002. Volume 3

    DTIC Science & Technology

    2002-05-13

    Mount • Install Large Capacity Ammo Container On Mount • Add Actuators And Resolvers For Laying OCSW Independent Of Main Gun t ti f t ti...FY07 FY08 FY09 FY10 FY11 FY12 4 5 6 SI Prod Block II (2K FLIR,Dual Feed, CPU Upgrade, AP Enhancements, MEMS) IOT &E LFT&E LUT...PQT Fielding (T) SDD C&TD Production LRIP SDD Prototypes Prototype Build BDENET MS B FRP MS C LRIP FCS S D D P ro to ty p es IOTE SD LRIP OCSW

  8. Preliminary design package for prototype solar heating and cooling systems

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A summary is given of the preliminary analysis and design activity on solar heating and cooling systems. The analysis was made without site specific data other than weather; therefore, the results indicate performance expected under these special conditions. Major items include a market analysis, design approaches, trade studies and other special data required to evaluate the preliminary analysis and design. The program calls for the development and delivery of eight prototype solar heating and cooling systems for installation and operational test. Two heating and six heating and cooling units will be delivered for Single Family Residences, Multiple-family Residences and commercial applications.

  9. Field test results with the targeted search MCSA. [multi-channel spectrum analyzer for SETI

    NASA Technical Reports Server (NTRS)

    Tarter, J. C.

    1988-01-01

    In April 1985, a 74,000 channel prototype of the multichannel spectrum analyzer (MCSA) that NASA plans to use in a systematic search for extraterrestrial intelligence (SETI) was installed at DSS13, a 26 meter R&D antenna facility at the Goldstone Deep Space Network (DSN) site. Since that time the instrumentation has been used to validate the performance of signal detection algorithms using locally injected signals and the weak carriers from distant spacecraft. This paper describes results from the Goldstone Field Tests and plans to move the prototype equipment to other sites where SETI may be conducted in the future.

  10. Prototype to measure bracket debonding force in vivo.

    PubMed

    Tonus, Jéssika Lagni; Manfroi, Fernanda Borguetti; Borges, Gilberto Antonio; Grigolo, Eduardo Correa; Helegda, Sérgio; Spohr, Ana Maria

    2017-02-01

    Material biodegradation that occurs in the mouth may interfere in the bonding strength between the bracket and the enamel, causing lower bond strength values in vivo, in comparison with in vitro studies. To develop a prototype to measure bracket debonding force in vivo and to evaluate, in vitro, the bond strength obtained with the prototype. A original plier (3M Unitek) was modified by adding one strain gauge directly connected to its claw. An electronic circuit performed the reading of the strain gauge, and the software installed in a computer recorded the values of the bracket debonding force, in kgf. Orthodontic brackets were bonded to the facial surface of 30 bovine incisors with adhesive materials. In Group 1 (n = 15), debonding was carried out with the prototype, while tensile bond strength testing was performed in Group 2 (n = 15). A universal testing machine was used for the second group. The adhesive remnant index (ARI) was recorded. According to Student's t test (α = 0.05), Group 1 (2.96 MPa) and Group 2 (3.08 MPa) were not significantly different. ARI score of 3 was predominant in the two groups. The prototype proved to be reliable for obtaining in vivo bond strength values for orthodontic brackets.

  11. Development of a Post-Installed Deepwater Monitoring System

    NASA Technical Reports Server (NTRS)

    Seaman, C.; Brower, D. V.; Tang, H.; Le, S.

    2015-01-01

    A monitoring system that can be deployed on already existing deep water risers and flowlines has been developed. This paper describes the design concepts and testing that was performed in developing the monitoring system. A major challenge of a post-installed instrumentation system is to ensure adequate coupling is achieved between the instruments and the riser or flowline. This work investigates the sensor coupling for pipelines that are suspended in both the water column (from topside platform to the seabed) and for those that are located directly on the seabed. These different environments have resulted in two sensor attachment methods: (1) subsea adhesive sensor clamp design and (2) a friction surface sensor attachment method. This paper presents the adhesive attachment method. The monitoring elements consist of fiber optic sensors that are encased in a polyurethane clamp. With a subsea adhesive, the clamp can be installed by divers in shallow depths or by use of an ROV for deeper applications. The NASA Johnson Space Center was initially involved in the selection and testing of subsea adhesives. It was determined that up to 75 percent of the bonding strength could be achieved with the adhesive from optimal dry bonding versus bonding in submerged sea water environments. The next phase of the study involved the design, fabrication, and testing of several prototype clamps that contained the fiber optic sensors. A mold was produced by NASA using 3-D printing methods that allowed the fabrication of subscale test articles that would accommodate 4-inch and 8-inch diameter pipes. The clamps were installed with adhesive in a "wet" environment on the pipe test articles and tested in the NASA Structures Test Laboratory. The tension/compression and bending tests showed that the prototype sensor clamps achieved good coupling, and could provide high quality strain measurement for active monitoring.

  12. A beam-splitter-type 3-D endoscope for front view and front-diagonal view images.

    PubMed

    Kamiuchi, Hiroki; Masamune, Ken; Kuwana, Kenta; Dohi, Takeyoshi; Kim, Keri; Yamashita, Hiromasa; Chiba, Toshio

    2013-01-01

    In endoscopic surgery, surgeons must manipulate an endoscope inside the body cavity to observe a large field-of-view while estimating the distance between surgical instruments and the affected area by reference to the size or motion of the surgical instruments in 2-D endoscopic images on a monitor. Therefore, there is a risk of the endoscope or surgical instruments physically damaging body tissues. To overcome this problem, we developed a Ø7- mm 3-D endoscope that can switch between providing front and front-diagonal view 3-D images by simply rotating its sleeves. This 3-D endoscope consists of a conventional 3-D endoscope and an outer and inner sleeve with a beam splitter and polarization plates. The beam splitter was used for visualizing both the front and front-diagonal view and was set at 25° to the outer sleeve's distal end in order to eliminate a blind spot common to both views. Polarization plates were used to avoid overlap of the two views. We measured signal-to-noise ratio (SNR), sharpness, chromatic aberration (CA), and viewing angle of this 3-D endoscope and evaluated its feasibility in vivo. Compared to the conventional 3-D endoscope, SNR and sharpness of this 3-D endoscope decreased by 20 and 7 %, respectively. No significant difference was found in CA. The viewing angle for both the front and front-diagonal views was about 50°. In the in vivo experiment, this 3-D endoscope can provide clear 3-D images of both views by simply rotating its inner sleeve. The developed 3-D endoscope can provide the front and front-diagonal view by simply rotating the inner sleeve, therefore the risk of damage to fragile body tissues can be significantly decreased.

  13. A Case Report of Sleeve Fracture of the Patella in a Shield.

    PubMed

    Tsubosaka, Masanori; Makino, Takeshi; Kishimoto, Shin-Ichiro; Yamaura, Kohei

    2016-01-01

    Sleeve fractures of the patella are rare fractures that only occur in children. The diagnosis is difficult both clinically and radiologically since the distal bony fragment may be too small to be detectable by radiography. A high-riding patella and hemarthrosis are important signs of sleeve fractures. A 12-year-old boy was admitted to the emergency room after having felt a severe pain in his left knee on kicking the ground while skateboarding earlier that day. Knee swelling, tense hemarthrosis, and periarticular tenderness were noted. On physical examination, an extension lag of 15 was observed. The active range of motion of the injured knee was 45-90° of flexion. Radiography showed an avulsion fracture of the lower pole of the patella and a high-riding patella. At the next day after the injury, we performed open reduction and internal fixation surgery. Open reduction with transosseous tunneling and cerclage wiring was performed because the distal bony fragment was too small for tension band wiring to be used. At 9 months after surgery, there was no extension lag, and the active range of motion of the injured knee was 0-140° of flexion. Callus formation over the fracture site and bone union was confirmed, and the cerclage wire was removed. To date, he had no further symptoms and has been able to carry out all types of physical activities, including skateboarding. Although sleeve fractures in children are uncommon, it should be considered a possibility in children with a chief complaint of pain around the knee. Open reduction and internal fixation was effective in the treatment of sleeve fracture of the patella.

  14. Compared to Sleeve Gastrectomy, Duodenal-Jejunal Bypass with Sleeve Gastrectomy Gives Better Glycemic Control in T2DM Patients, with a Lower β-Cell Response and Similar Appetite Sensations: Mixed-Meal Study.

    PubMed

    Zachariah, Pulimuttil James; Chen, Chih-Yen; Lee, Wei-Jei; Chen, Shu-Chu; Ser, Kong-Han; Chen, Jung-Chien; Lee, Yi-Chih

    2016-12-01

    Functional studies of how duodenal-jejunal exclusion (DJE) brings a superior glycemic control when added to sleeve gastrectomy in duodenal-jejunal bypass with sleeve gastrectomy (DJB-SG) patients, are lacking. To study this, we compared the appetite sensations and the β-cell response following a standard mixed meal in patients with DJB-SG, versus those with sleeve gastrectomy (SG) alone. Twenty one patients who underwent DJB-SG and 25 with SG, who participated in mixed-meal tests (MMTT) preoperatively and at 1 year, with complete data were included and compared. Blood glucose, C-peptide, and insulin levels were estimated, along with the visual analogue scale (VAS) scoring of the six appetite sensations, as a part of the MMTT. At 1 year following surgery, compared to SG group, DJB-SG group had greater complete remission rates (HbA1C <6.0 %) of 62 versus 32 % (p < 0.05), with similar total body weight loss (25.7 vs. 22 %). There were significantly lower post-prandial blood glucose and lower C-peptide levels during the MMTT in the patients with DJB-SG compared to SG group. There were no significant differences in the appetite sensations (mean VAS) scores between the groups. The addition of DJE component to SG, as in DJB-SG, was associated with higher diabetes remission rates, lower glycemic fluctuations, and lower C-peptide levels. This may point to a β-cell preserving glucose control which could result in longer remission of type 2 diabetes mellitus (T2DM). This effect also may be unrelated to food intake as there were no significant differences in the appetite sensations.

  15. Loss-of-Control Eating Following Sleeve Gastrectomy Surgery

    PubMed Central

    Ivezaj, Valentina; Kessler, Erin E.; Lydecker, Janet A.; Barnes, Rachel D.; White, Marney A.; Grilo, Carlos M.

    2016-01-01

    Background Post-operative loss-of-control (LOC) eating is related to poorer weight loss outcomes following bariatric surgery, but little is known about LOC eating following sleeve gastrectomy surgery. Objectives To examine LOC eating severity and weight loss following sleeve gastrectomy. Setting University School of Medicine, U.S. Methods Participants were 71 individuals (84.5% female; n=60) who underwent sleeve gastrectomy surgery within the previous 4–9 months and reported LOC eating at least once weekly during the previous 28 days. LOC eating was assessed using the Eating Disorder Examination (EDE) Bariatric Surgery Version. Current mean age and body mass index were 47.3 (SD=10.1) years and 37.9 (SD=8.2) kg/m2. Two groups, bariatric binge-eating disorder (Bar-BED) and loss-of-control eating only (LOC-Only) were created based on modified binge-eating disorder (BED) criteria, which excluded the “unusually large quantity of food” criterion due to limited gastric capacity post-surgery. Bar-BED criteria mirrored BED criteria and consisted of the following: at least 12 LOC eating episodes over the prior three months (once weekly), 3 of 5 associated symptoms, marked distress over LOC eating, and lack of regular compensatory behaviors. Results Based on these revised criteria, 49.3% (n=35) were classified as the Bar-BED group and 50.7% (n=36) as the LOC-Only group. Compared to the LOC-Only group, the Bar-BED group had significantly greater EDE global and subscale scores and lower percent weight loss by six months post-surgery. Conclusions Findings suggest LOC eating that parallels BED post-surgery is associated with poorer outcomes following sleeve gastrectomy including poorer weight loss and greater severity of eating-disorder psychopathology. PMID:27913121

  16. Precise method of compensating radiation-induced errors in a hot-cathode-ionization gauge with correcting electrode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saeki, Hiroshi, E-mail: saeki@spring8.or.jp; Magome, Tamotsu, E-mail: saeki@spring8.or.jp

    2014-10-06

    To compensate pressure-measurement errors caused by a synchrotron radiation environment, a precise method using a hot-cathode-ionization-gauge head with correcting electrode, was developed and tested in a simulation experiment with excess electrons in the SPring-8 storage ring. This precise method to improve the measurement accuracy, can correctly reduce the pressure-measurement errors caused by electrons originating from the external environment, and originating from the primary gauge filament influenced by spatial conditions of the installed vacuum-gauge head. As the result of the simulation experiment to confirm the performance reducing the errors caused by the external environment, the pressure-measurement error using this method wasmore » approximately less than several percent in the pressure range from 10{sup −5} Pa to 10{sup −8} Pa. After the experiment, to confirm the performance reducing the error caused by spatial conditions, an additional experiment was carried out using a sleeve and showed that the improved function was available.« less

  17. Liner for extrusion billet containers. Interim Technical Documentary Progress Report, February 1--April 30, 1963

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spachner, S. A.

    1963-05-01

    A shrink-fit assembly device for buildup of ceramiccoated liner and sleeve assemblies was tested and modified to develop desired temperatures and suitable heat distribution in sleeves, which were heated. Nine different compositions of fiber metal reinforced ceramic compacts were produced for preliminary evaluation of suitability for extrusion liner use. Procedures were developed for welding short, hollow ceramic cylinders of high-strength metal carbides and borides to form a ceramic extrusion liner of suitable length. Dissassembly tooling for rapid separation of shrink-fitted sleeves from a worn liner was designed, fabricated, and tested. Preliminary extrusion testing of an alumina-coated liner was carried out,more » using SAE 4340 steel billets extruded to rod at 12 : 1 and 16 : 1 ratios. No coating wear was noted after extrusion of 3 billets. (auth)« less

  18. Combustor assembly in a gas turbine engine

    DOEpatents

    Wiebe, David J; Fox, Timothy A

    2015-04-28

    A combustor assembly in a gas turbine engine includes a combustor device, a fuel injection system, a transition duct, and an intermediate duct. The combustor device includes a flow sleeve for receiving pressurized air and a liner surrounded by the flow sleeve. The fuel injection system provides fuel to be mixed with the pressurized air and ignited in the liner to create combustion products. The intermediate duct is disposed between the liner and the transition duct so as to define a path for the combustion products to flow from the liner to the transition duct. The intermediate duct is associated with the liner such that movement may occur therebetween, and the intermediate duct is associated with the transition duct such that movement may occur therebetween. The flow sleeve includes structure that defines an axial stop for limiting axial movement of the intermediate duct.

  19. Biosleeve Human-Machine Interface

    NASA Technical Reports Server (NTRS)

    Assad, Christopher (Inventor)

    2016-01-01

    Systems and methods for sensing human muscle action and gestures in order to control machines or robotic devices are disclosed. One exemplary system employs a tight fitting sleeve worn on a user arm and including a plurality of electromyography (EMG) sensors and at least one inertial measurement unit (IMU). Power, signal processing, and communications electronics may be built into the sleeve and control data may be transmitted wirelessly to the controlled machine or robotic device.

  20. 75 FR 20931 - Airworthiness Directives; Eurocopter France (ECF) Model SA-365N1, AS-365N2, AS 365 N3, EC 155B...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-22

    ... Community. The MCAI AD reports the separation and loss of a stainless steel ring (75 millimeter (mm) in... of a stainless steel ring (75 mm in diameter) from a blade sleeve resulting in severe, high-frequency... information specifies checking the blade sleeve for slippage of the stainless steel ring (75 mm in diameter...

  1. Laparoscopic sleeve gastrectomy for morbid obesity with natural orifice specimen extraction (NOSE).

    PubMed

    Gunkova, P; Gunka, I; Zonca, P; Dostalik, J; Ihnat, P

    2015-01-01

    An experience with laparoscopic sleeve gastrectomy using the natural orifice specimen extraction (NOSE) technique. Bariatric surgery is nowadays the only long term effective obesity treatment method. Twenty one consecutive patients underwent laparoscopic sleeve gastrectomy with the use of natural orifice specimen extraction (NOSE) in the Surgical Clinic of Faculty Hospital Ostrava between May 2012 and August 2012. Inclusion criteria were the body mass index (BMI) higher than 35 kg/m2 or higher than 32 kg/m2 accompanied with relevant comorbidities. Among 21 patients in this series, there were three men (14.3%) and 18 women (85.7%). Their mean age was 40.9±10.2 years. Their mean preoperative BMI was 40.4±4.6 kg/m2. No patient had previous bariatric surgery, one patient had laparoscopic fundoplication. All operations were completed laparoscopically with no conversions to an open procedure. In two cases, laparoscopic cholecystectomy was performed and the gallbladder was extracted along with the gastric specimen by transgastric approach. Laparoscopic sleeve gastrectomy is a safe and effective bariatric procedure with low morbidity and mortality. Based on our initial experiences it could be an indication for NOSE with transgastric approach. Obese patients would benefit from this approach due to the elimination of wound complications (Tab. 2, Fig. 3, Ref. 22).

  2. Effects of wearing lower leg compression sleeves on locomotion economy.

    PubMed

    Kurz, Eduard; Anders, Christoph

    2018-09-01

    The purpose of this investigation was to assess the effect of compression sleeves on muscle activation cost during locomotion. Twenty-two recreationally active men (age: 25 ± 3 years) ran on a treadmill at four different speeds (ordered sequence of 2.8, 3.3, 2.2, and 3.9 m/s). The tests were performed without (control situation, CON) and while wearing specially designed lower leg compression sleeves (SL). Myoelectric activity of five lower leg muscles (tibialis anterior, fibularis longus, lateral and medial head of gastrocnemius, and soleus) was captured using Surface EMG. To assess muscle activation cost, the cumulative muscle activity per distance travelled (CMAPD) of the CON and SL situations was determined. Repeated measures analyses of variance were performed separately for each muscle. The analyses revealed a reduced lower leg muscle activation cost with respect to test situation for SL for all muscles (p < 0.05, η p 2  > 0.18). The respective significant reductions of CMAPD values during SL ranged between 4% and 16% and were largest at 2.8 m/s. The findings presented point towards an improved muscle activation cost while wearing lower leg compression sleeves during locomotion that have potential to postpone muscle fatigue.

  3. Laparoscopic Sleeve Gastrectomy Improves Olfaction Sensitivity in Morbidly Obese Patients.

    PubMed

    Hancı, Deniz; Altun, Huseyin; Altun, Hasan; Batman, Burcin; Karip, Aziz Bora; Serin, Kursat Rahmi

    2016-03-01

    Olfactory abilities of the patients are known to be altered by eating and metabolic disorders, including obesity. There are only a number of studies investigating the effect of obesity on olfaction, and there is limited data on the changes in olfactory abilities of morbidly obese patients after surgical treatment. Here we investigated the changes in olfactory abilities of 54 morbidly obese patients (M/F, 22/32; age range 19-57 years; body mass index (BMI) range 30.5-63.0 kg/m(2)) after laparoscopic sleeve gastrectomy. A laparoscopic sleeve gastrectomy was performed by the same surgeon using five-port technique. Olfactory abilities were tested preoperatively and 1, 3, and 6 months after the surgery using a standardized Sniffin' Sticks Extended Test kit. Analyses of variance indicated statistically significant improvement in T, D, and I scores of morbidly obese patients within time factors (preoperative vs. 1, 3, and 6 months; 1 vs. 3 and 6 months; and 3 vs. 6 months; p < 0.001 for all). There was a statistically significant improvement in overall TDI scores with an increase from 25 to 41 during the 6 months follow-up period (p < 0.001 for all). Here, for the first time in literature, we were able to show the significant improvement in olfactory abilities of morbidly obese patients after laparoscopic sleeve gastrectomy.

  4. Knee braces can decrease tibial rotation during pivoting that occurs in high demanding activities.

    PubMed

    Giotis, Dimitrios; Tsiaras, Vasilios; Ristanis, Stavros; Zampeli, Franceska; Mitsionis, Grigoris; Stergiou, Nicholas; Georgoulis, Anastasios D

    2011-08-01

    The purpose of this study was to investigate whether knee braces could effectively decrease tibial rotation during high demanding activities. Using an in vivo three-dimensional kinematic analysis, 21 physically active, healthy, male subjects were evaluated. Each subject performed two tasks that were used extensively in the literature because they combine increased rotational and translational loads on the knee, (1) descending from a stair and subsequent pivoting and (2) landing from a platform and subsequent pivoting under three conditions: (A) wearing a prophylactic brace (braced), (B) wearing a patellofemoral brace (sleeved), and (C) unbraced condition. In the first task, tibial rotation during the pivoting phase was significantly decreased in the braced condition as compared to the sleeved condition (P = 0.019) and the non-braced condition (P = 0.002). In the second task, the same variable was significantly decreased in the braced condition as compared to the sleeved (P = 0.001) and the unbraced condition (P < 0.001). The sleeved condition also produced significantly decreased tibial rotation with respect to the unbraced condition (P = 0.021). Bracing decreased tibial rotation in activities where increased translational and rotational forces were applied. Because knee braces decreased tibial rotation, they can possibly be used with ACL-reconstructed and ACL-deficient patients to prevent such problems. Case-control study, Level III.

  5. [The technique of sleeve resection on the bronchial and pulmonary vascular tree].

    PubMed

    Branscheid, D; Beshay, M

    2013-06-01

    Sleeve resections of the lungs have affected the oncologic radicality, parenchyma and lung function-saving resections and extended the indications for operations in thoracic surgery. Whenever lung amputations can be avoided by bronchoplastic and/or angioplastic procedures with the same radicality, sleeve resection should be performed. In centrally located distinct malignomas, intraluminal tumor growth (T3) infiltrations of peribronchial or extrabronchial areas, the lobular ostia and the pulmonary artery (T2/T3) as well as lymph node involvement (N1/N2), these procedures give a better qualitative survival and lower morbidity and mortality rates. Broncoscope-guided localization of a double lumen tube and routine anesthesia monitoring are mandatory. Before performing sleeve resections a complete lymph node dissection should be done without denuding the area of the anastomosis and sparing the bronchial arteries. Preoperative endoscopic biopsies, knowledge of the topography and mobilization of the vascular and bronchial tree, subtile operation techniques, perioperative and postoperative videobronchoscopic guidance as well as intraoperative frozen sections and a tension-free and smooth anastomosis, avoid postoperative complications. Depending on the blood supply of the bronchial tree a vascularized flap is indicated. Operability can therefore be achieved in elderly patients with limited pulmonary function, particularly those under adjuvant or neoadjuvant therapy who are no longer suitable for pneumonectomy.

  6. Endoscopic Sleeve Gastroplasty - A New Tool to Manage Obesity

    PubMed Central

    Jain, Deepanshu; Bhandari, Bharat Singh; Arora, Ankit; Singhal, Shashideep

    2017-01-01

    Obesity is a growing pandemic across the world. Dietary restrictions and behavior modifications alone have a limited benefit. Bariatric surgery, despite being the current gold standard, has limited acceptance by patients due to cost and associated morbidity. In our review, we have discussed nine original studies describing endoscopic sleeve gastroplasty (ESG). A total of 172 subjects successfully underwent ESG. Of 65 subjects with follow up data, 95.4% (62/65) had intact gastric sleeve confirmed via esophagogastroduodenoscopy or oral contrast study at the end of study specific follow up interval (the longest being 6 months). Individual studies reported a technical success rate for intact gastric sleeve from as low as 50% to as high as 100%. A statistically significant p<0.05) weight loss was reported in seven of the eight studies with available data. None of the patients experienced any intra-procedure complications, and approximately 2.3% (4/172) of patients experienced major post-procedure complications; however, no mortality was reported. Majority of the studies reported relatively high incidence of minor post-procedure complications, which improved with symptomatic treatment alone. Good patient tolerance with comparable clinical efficacy in achieving and sustaining desired weight loss makes ESG an attractive option to consider among other bariatric therapies. PMID:28607328

  7. Construction of the DHCAL

    NASA Astrophysics Data System (ADS)

    Francis, Kurt; CALICE Collaboration

    Particle Flow Algorithms (PFAs) have been proposed as a method of improving the jet energy resolution of future colliding beam detectors. PFAs require calorimeters with high granularity to enable three-dimensional imaging of events. The Calorimeter for the Linear Collider Collaboration (CALICE) is developing and testing prototypes of such highly segmented calorimeters. In this context, a large prototype of a Digital Hadron Calorimeter (DHCAL) was developed and constructed by a group led by Argonne National Laboratory. The DHCAL consists of 52 layers, instrumented with Resistive Plate Chambers (RPCs) and interleaved with steel absorber plates. The RPCs are read out by 1 x 1 cm2 pads with a 1-bit resolution (digital readout). The DHCAL prototype has approximately 480,000 readout channels. This talk reports on the design, construction and commissioning of the DHCAL. The DHCAL was installed at the Fermilab Test Beam Facility in fall 2010 and data was collected through the summer 2011.

  8. Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jang, Hyojae, E-mail: lkcom@ibs.re.kr; Jin, Hyunchang; Jang, Ji-Ho

    2016-02-15

    A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, developmentmore » of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.« less

  9. Improvement of immunoassay detection system by using alternating current magnetic susceptibility

    NASA Astrophysics Data System (ADS)

    Kawabata, R.; Mizoguchi, T.; Kandori, A.

    2016-03-01

    A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.

  10. Improvement of immunoassay detection system by using alternating current magnetic susceptibility.

    PubMed

    Kawabata, R; Mizoguchi, T; Kandori, A

    2016-03-01

    A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.

  11. EC00-0283-3

    NASA Image and Video Library

    2000-09-18

    An engineer at AeroVironment's Design Development Center in Simi Valley, California, closely inspects a set of silicon solar cells for potential defects. The cells, fabricated by SunPower, Inc., of Sunnyvale, California, are among 64,000 solar cells which have been installed on the Helios Prototype solar-powered aircraft to provide power to its 14 electric motors and operating systems.

  12. EC00-0283-9

    NASA Image and Video Library

    2000-09-18

    A technician at AeroVironment's Design Development Center in Simi Valley, California, checks a panel of silicon solar cells for conductivity and voltage. The bi-facial cells, fabricated by SunPower, Inc., of Sunnyvale, California, are among 64,000 solar cells which have been installed on the Helios Prototype solar-powered aircraft to provide power to its 14 electric motors and operating systems.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zvi H. Meiksin

    Two industrial prototype units for through-the-earth wireless communication were constructed and tested. Preparation for a temporary installation in NIOSH's Lake Lynn mine for the through-the-earth and the in-mine system were completed. Progress was made in the programming of the in-mine system to provide data communication. Work has begun to implement a wireless interface between equipment controllers and our in-mine system.

  14. Solar energy system performance evaluation: Seasonal report for IBM System 2, Togus, Maine

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The solar energy system, SIMS Prototype System 2, was designed to supply domestic hot water to single family residences. The system consists of flat plate collectors, silicone working fluid, storage tanks, pumps, heat exchanger, controls, and associated plumbing. The long term field performance of the installed system was analyzed and the results are described.

  15. Automated meteorological data from commercial aircraft via satellite - Present experience and future implications

    NASA Technical Reports Server (NTRS)

    Steinberg, R.

    1978-01-01

    The National Aeronautics and Space Administration has developed a low-cost communications system to provide meteorological data from commercial aircraft, in near real-time, on a fully automated basis. The complete system including the low profile antenna and all installation hardware weighs 34 kg. The prototype system has been installed on a Pan American B-747 aircraft and has been providing meteorological data (wind angle and velocity, temperature, altitude and position as a function of time) on a fully automated basis for the past several months. The results have been exceptional. This concept is expected to have important implications for operational meteorology and airline route forecasting.

  16. Satellite relay telemetry of seismic data in earthquake prediction and control

    USGS Publications Warehouse

    Jackson, Wayne H.; Eaton, Jerry P.

    1971-01-01

    The Satellite Telemetry Earthquake Monitoring Program was started in FY 1968 to evaluate the applicability of satellite relay telemetry in the collection of seismic data from a large number of dense seismograph clusters laid out along the major fault systems of western North America. Prototype clusters utilizing phone-line telemetry were then being installed by the National Center for Earthquake Research (NCER) in 3 regions along the San Andreas fault in central California; and the experience of installing and operating the clusters and in reducing and analyzing the seismic data from them was to provide the raw materials for evaluation in the satellite relay telemetry project.

  17. Solar heating and cooling system design and development

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The progress of the program during the sixth program quarter is reported. The program calls for the development and delivery of eight prototype solar heating and cooling systems for installation and operational test. The William O'Brien single-family heating system was installed and is operational. The New Castle single-family heating residence is under construction. The Kansas University (KU) system is in the final design stages. The 25 ton cooling subsystem for KU is the debugging stage. Pressure drops that were greater than anticipated were encountered. The 3 ton simulation work is being finalized and the design parameters for the Rankine system were determined from simulation output.

  18. A Scalable Software Architecture Booting and Configuring Nodes in the Whitney Commodity Computing Testbed

    NASA Technical Reports Server (NTRS)

    Fineberg, Samuel A.; Kutler, Paul (Technical Monitor)

    1997-01-01

    The Whitney project is integrating commodity off-the-shelf PC hardware and software technology to build a parallel supercomputer with hundreds to thousands of nodes. To build such a system, one must have a scalable software model, and the installation and maintenance of the system software must be completely automated. We describe the design of an architecture for booting, installing, and configuring nodes in such a system with particular consideration given to scalability and ease of maintenance. This system has been implemented on a 40-node prototype of Whitney and is to be used on the 500 processor Whitney system to be built in 1998.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, K.; Markel, T.; Simpson, M.

    The U.S. Army's Fort Carson installation was selected to serve as a prototype for net zero energy assessment and planning. NREL performed the comprehensive assessment to appraise the potential of Fort Carson to achieve net zero energy status through energy efficiency, renewable energy, and electric vehicle integration. This report summarizes the results of the assessment and provides energy recommendations. This study is part of a larger cross-laboratory effort that also includes an assessment of renewable opportunities at seven other DoD Front Range installations, a microgrid design for Fort Carson critical loads and an assessment of regulatory and market-based barriers tomore » a regional secure smart grid.« less

  20. Knitted Strain Sensor Textiles of Highly Conductive All-Polymeric Fibers.

    PubMed

    Seyedin, Shayan; Razal, Joselito M; Innis, Peter C; Jeiranikhameneh, Ali; Beirne, Stephen; Wallace, Gordon G

    2015-09-30

    A scaled-up fiber wet-spinning production of electrically conductive and highly stretchable PU/PEDOT:PSS fibers is demonstrated for the first time. The PU/PEDOT:PSS fibers possess the mechanical properties appropriate for knitting various textile structures. The knitted textiles exhibit strain sensing properties that were dependent upon the number of PU/PEDOT:PSS fibers used in knitting. The knitted textiles show sensitivity (as measured by the gauge factor) that increases with the number of PU/PEDOT:PSS fibers deployed. A highly stable sensor response was observed when four PU/PEDOT:PSS fibers were co-knitted with a commercial Spandex yarn. The knitted textile sensor can distinguish different magnitudes of applied strain with cyclically repeatable sensor responses at applied strains of up to 160%. When used in conjunction with a commercial wireless transmitter, the knitted textile responded well to the magnitude of bending deformations, demonstrating potential for remote strain sensing applications. The feasibility of an all-polymeric knitted textile wearable strain sensor was demonstrated in a knee sleeve prototype with application in personal training and rehabilitation following injury.

  1. The energy performance of prototype holographic glazings

    NASA Astrophysics Data System (ADS)

    Papamichael, K.; Beltran, L.; Furler, R.; Lee, E. S.; Selkowitz, S.; Rubin, M.

    1993-02-01

    We report on the simulation of the energy performance of prototype holographic glazings in commercial office buildings in a California climate. These prototype glazings, installed above conventional side windows, are designed to diffract the transmitted solar radiation and reflect it off the ceiling, providing adequate daylight illumination for typical office tasks up to 10m from the window. In this study, we experimentally determined a comprehensive set of solar-optical properties and characterized the contribution of the prototype holographic glazings to workplane illuminance in a scale model of a typical office space. We then used the scale model measurements to simulate the energy performance of the holographic glazings over the course of an entire year for four window orientations (North, East, South and West) for the inland Los Angeles climate, using the DOE-2.lD building energy analysis computer program. The results of our experimental analyses indicate that these prototype holographic glazings diffract only a small fraction of the incident light. The results of this study indicate that these prototype holographic glazings will not save energy in commercial office buildings. Their performance is very similar to that of clear glass, which, through side windows, cannot efficiently illuminate more than a 4-6 m depth of a building's perimeter, because the cooling penalties due to solar heat gain are greater than the electric lighting savings due to daylighting.

  2. Spacelab data processing facility (SLDPF) quality assurance (QA)/data accounting (DA) expert systems - Transition from prototypes to operational systems

    NASA Technical Reports Server (NTRS)

    Basile, Lisa

    1988-01-01

    The SLDPF is responsible for the capture, quality monitoring processing, accounting, and shipment of Spacelab and/or Attached Shuttle Payloads (ASP) telemetry data to various user facilities. Expert systems will aid in the performance of the quality assurance and data accounting functions of the two SLDPF functional elements: the Spacelab Input Processing System (SIPS) and the Spacelab Output Processing System (SOPS). Prototypes were developed for each as independent efforts. The SIPS Knowledge System Prototype (KSP) used the commercial shell OPS5+ on an IBM PC/AT; the SOPS Expert System Prototype used the expert system shell CLIPS implemented on a Macintosh personal computer. Both prototypes emulate the duties of the respective QA/DA analysts based upon analyst input and predetermined mission criteria parameters, and recommended instructions and decisions governing the reprocessing, release, or holding for further analysis of data. These prototypes demonstrated feasibility and high potential for operational systems. Increase in productivity, decrease of tedium, consistency, concise historical records, and a training tool for new analyses were the principal advantages. An operational configuration, taking advantage of the SLDPF network capabilities, is under development with the expert systems being installed on SUN workstations. This new configuration in conjunction with the potential of the expert systems will enhance the efficiency, in both time and quality, of the SLDPF's release of Spacelab/AST data products.

  3. Spacelab data processing facility (SLDPF) Quality Assurance (QA)/Data Accounting (DA) expert systems: Transition from prototypes to operational systems

    NASA Technical Reports Server (NTRS)

    Basile, Lisa

    1988-01-01

    The SLDPF is responsible for the capture, quality monitoring processing, accounting, and shipment of Spacelab and/or Attached Shuttle Payloads (ASP) telemetry data to various user facilities. Expert systems will aid in the performance of the quality assurance and data accounting functions of the two SLDPF functional elements: the Spacelab Input Processing System (SIPS) and the Spacelab Output Processing System (SOPS). Prototypes were developed for each as independent efforts. The SIPS Knowledge System Prototype (KSP) used the commercial shell OPS5+ on an IBM PC/AT; the SOPS Expert System Prototype used the expert system shell CLIPS implemented on a Macintosh personal computer. Both prototypes emulate the duties of the respective QA/DA analysts based upon analyst input and predetermined mission criteria parameters, and recommended instructions and decisions governing the reprocessing, release, or holding for further analysis of data. These prototypes demonstrated feasibility and high potential for operational systems. Increase in productivity, decrease of tedium, consistency, concise historial records, and a training tool for new analyses were the principal advantages. An operational configuration, taking advantage of the SLDPF network capabilities, is under development with the expert systems being installed on SUN workstations. This new configuration in conjunction with the potential of the expert systems will enhance the efficiency, in both time and quality, of the SLDPF's release of Spacelab/AST data products.

  4. CUSHIONED BEARING

    DOEpatents

    Rushing, F.C.

    1960-09-01

    A vibration damping device effective to dampen vibrations occurring at the several critical speeds encountered in the operation of a high-speed centrifuge is described. A self-centering bearing mechanism is used to protect both the centrifuge shaft and the damping mechanism. The damping mechanism comprises spaced-apant, movable, and stationary sleeve members arranged concentrically of a rotating shaft with a fluid maintained between the members. The movable sleeve member is connected to the shaft for radial movement therewith.

  5. A high-speed photography study of cavitation in a dynamically loaded journal bearing

    NASA Technical Reports Server (NTRS)

    Sun, D. C.; Brewe, D. E.

    1990-01-01

    The earlier study made by Jacobson and Hamrock on the cavitation of liquid lubricant films in a dynamically loaded journal bearing was repeated with a quartz sleeve, which was more rigid than the Polymethylmethacrylate (PMMA) sleeve used previously. Various improvements of the test rig were made concomitantly so that the experimental errors could be better controlled and assessed. The updated speed photography experiment and its results are described.

  6. A high speed photography study of cavitation in a dynamically loaded journal bearing

    NASA Technical Reports Server (NTRS)

    Sun, D. C.; Brewe, D. E.

    1991-01-01

    The earlier study made by Jacobson and Hamrock on the cavitation of liquid lubricant films in a dynamically loaded journal bearing was repeated with a quartz sleeve, which was more rigid than the Polymethylmethacrylate (PMMA) sleeve used previously. Various improvements of the test rig were made concomitantly so that the experimental errors could be better controlled and assessed. The updated speed photography experiment and its results are described.

  7. GRIPPING DEVICE FOR CYLINDRICAL OBJECTS

    DOEpatents

    Pilger, J.P.

    1964-01-21

    A gripping device is designed for fragile cylindrical objects such as for drawing thin-walled tubes. The gripping is done by multiple jaw members held in position by two sets of slots, one defined by keystone-shaped extensions of the outer shell of the device and the other in a movable sleeve held slidably by the extensions. Forward movement oi the sleeve advances the jaws, thereby exerting a controlled, radial pressure on the object being gripped. (AEC)

  8. CABLE CONNECTOR

    DOEpatents

    Caller, J.M.

    1962-05-01

    An electrical connector is designed for utilization in connection with either round or flat coaxial cables. The connector comprises a bayonet-type coupling arrangement with a splined movable locking sleeve adapted to lock together components of the connector. A compression spring is attached to one of the connector components and functions to forcibly separate mating components when the locking sleeve is in an unlocked condition so as to minimize the possibility of leaving the conductors electrically coupled. (AEC)

  9. Cap assembly for a bundled tube fuel injector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LeBegue, Jeffrey Scott; Melton, Patrick Benedict; Westmoreland, III, James Harold

    2016-04-26

    A cap assembly for a bundled tube fuel injector includes an impingement plate and an aft plate that is disposed downstream from the impingement plate. The aft plate includes a forward side that is axially separated from an aft side. A tube passage extends through the impingement plate and the aft plate. A tube sleeve extends through the impingement plate within the tube passage towards the aft plate. The tube sleeve includes a flange at a forward end and an aft end that is axially separated from the forward end. A retention plate is positioned upstream from the impingement plate.more » A spring is disposed between the retention plate and the flange. The spring provides a force so as to maintain contact between at least a portion of the aft end of the tube sleeve and the forward side of the aft plate.« less

  10. Ion-plasma gun for ion-milling machine

    DOEpatents

    Kaminsky, Manfred S.; Campana, Jr., Thomas J.

    1976-01-01

    An ion gun includes an elongated electrode with a hollow end portion closed by a perforated end plate. The end plate is positioned parallel to a perforated flat electrode of opposite electrical polarity. An insulated sleeve encompasses the elongated electrode and extends outwardly from the perforated end towards the flat electrode. The sleeve length is separated into two portions of different materials. The first is formed of a high-temperature material that extends over the hollow portion of the elongated electrode where the arc is initiated by a point source electrode. The second sleeve portion extending over the remainder of the elongated electrode is of a resilient material for enhanced seal-forming ability and retention of plasma gas. Perforations are arranged in the flat electrode in a mutually opposing triangular pattern to project a plasma beam having a generally flat current profile towards a target requiring precision milling.

  11. IMPROVEMENTS IN OR RELATING TO NUCLEAR REACTORS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis, W.E.; Lindley, P.A.

    1958-05-01

    A unique feature of the GEC Hunterston power station is the use of what the firm call the 'replaceable channel fuel element' and the patent covers the idea. The actual metallic element is generally simlar to those used in other power stations--a uranium bar sheathed in a helically-finned can--but it is supported inside a sleeve of graphite or other material. The composite elements are stacked inside channels through the core and are charged and discharged as complete units. The advantages claimed are: the core channels are protected against mechanical abrasion during fuelling operation, the moderator is protected against chemical attackmore » and mass transfer from the coolant, and if there is a burst slug it is only the sleeve which is contaminated. The sleeve also takes all the weight, thus elements are unlformly stressed. Working on this idea, the specification covers several variants, including the use of plate-type elements.« less

  12. Method for making an elastomeric member with end pieces

    DOEpatents

    Hoppie, L.O.; McNinch, J.H. Jr.; Nowell, G.C.

    1984-10-23

    A molding process is described for molding an elongated elastomeric member with wire mesh sleeves bonded to the ends. A molding preform of elastomeric material is positioned within a seamless mold cylinder, and the open ends of the wire mesh sleeves are mounted to end plug assemblies slidably received into the mold cylinder and positioned against the ends of the preform. A specialized profile is formed into surfaces of the respective end plug assemblies and by heating of the mold, the ends of the elastomeric preform are molded to the profile, as well as bonded to the reinforcing wire mesh sleeves. Vacuum is applied to the interior of the mold to draw outgassing vapors through relief spaces there through. The completed elastomeric member is removed from the mold cylinder by stretching, the consequent reduction in diameter enabling ready separation from the mold cylinder and removal thereof. 9 figs.

  13. Silicon-based sleeve devices for chemical reactions

    DOEpatents

    Northrup, M. Allen; Mariella, Jr., Raymond P.; Carrano, Anthony V.; Balch, Joseph W.

    1996-01-01

    A silicon-based sleeve type chemical reaction chamber that combines heaters, such as doped polysilicon for heating, and bulk silicon for convection cooling. The reaction chamber combines a critical ratio of silicon and silicon nitride to the volume of material to be heated (e.g., a liquid) in order to provide uniform heating, yet low power requirements. The reaction chamber will also allow the introduction of a secondary tube (e.g., plastic) into the reaction sleeve that contains the reaction mixture thereby alleviating any potential materials incompatibility issues. The reaction chamber may be utilized in any chemical reaction system for synthesis or processing of organic, inorganic, or biochemical reactions, such as the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction, which are examples of a synthetic, thermal-cycling-based reaction. The reaction chamber may also be used in synthesis instruments, particularly those for DNA amplification and synthesis.

  14. Silicon-based sleeve devices for chemical reactions

    DOEpatents

    Northrup, M.A.; Mariella, R.P. Jr.; Carrano, A.V.; Balch, J.W.

    1996-12-31

    A silicon-based sleeve type chemical reaction chamber is described that combines heaters, such as doped polysilicon for heating, and bulk silicon for convection cooling. The reaction chamber combines a critical ratio of silicon and silicon nitride to the volume of material to be heated (e.g., a liquid) in order to provide uniform heating, yet low power requirements. The reaction chamber will also allow the introduction of a secondary tube (e.g., plastic) into the reaction sleeve that contains the reaction mixture thereby alleviating any potential materials incompatibility issues. The reaction chamber may be utilized in any chemical reaction system for synthesis or processing of organic, inorganic, or biochemical reactions, such as the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction, which are examples of a synthetic, thermal-cycling-based reaction. The reaction chamber may also be used in synthesis instruments, particularly those for DNA amplification and synthesis. 32 figs.

  15. Preliminary engineering study: Quick opening valve MSFC high Reynolds number wind tunnel

    NASA Technical Reports Server (NTRS)

    1983-01-01

    FluiDyne Engineering Corporation has conducted a preliminary engineering study of a quick-opening valve for the MSFC High Reynolds Number Wind Tunnel under NASA Contract NAS8-35056. The subject valve is intended to replace the Mylar diaphragm system as the flow initiation device for the tunnel. Only valves capable of opening within 0.05 sec. and providing a minimum of 11.4 square feet of flow area were considered. Also, the study focused on valves which combined the quick-opening and tight shutoff features in a single unit. A ring sleeve valve concept was chosen for refinement and pricing. Sealing for tight shutoff, ring sleeve closure release and sleeve actuation were considered. The resulting cost estimate includes the valve and requisite modifications to the facility to accommodate the valve as well as the associated design and development work.

  16. Drive piston assembly for a valve actuator assembly

    DOEpatents

    Sun, Zongxuan

    2010-02-23

    A drive piston assembly is provided that is operable to selectively open a poppet valve. The drive piston assembly includes a cartridge defining a generally stepped bore. A drive piston is movable within the generally stepped bore and a boost sleeve is coaxially disposed with respect to the drive piston. A main fluid chamber is at least partially defined by the generally stepped bore, drive piston, and boost sleeve. First and second feedback chambers are at least partially defined by the drive piston and each are disposed at opposite ends of the drive piston. At least one of the drive piston and the boost sleeve is sufficiently configured to move within the generally stepped bore in response to fluid pressure within the main fluid chamber to selectively open the poppet valve. A valve actuator assembly and engine are also provided incorporating the disclosed drive piston assembly.

  17. Ultra high performance connectors for power transmission applications

    DOEpatents

    Wang, Jy-An; Ren, Fei; Lee, Dominic F; Jiang, Hao

    2014-03-04

    Disclosed are several examples of an apparatus for connecting the free ends of two electrical power transmission lines having conductor strands disposed around a central, reinforcing core. The examples include an inner sleeve having a body defining an inner bore passing through an axially-extending, central axis, an outer rim surface disposed radially outward from the central bore, and one or more axially-extending grooves penetrating the body at the outer rim surface. Also included is an outer splice having a tubular shaped body with a bore passing coaxially through the central axis, the bore defining an inner rim surface for accepting the inner sleeve. The inner bore of the inner sleeve accepts the reinforcement cores of the two conductors, and the grooves accept the conductor strands in an overlapping configuration so that a majority of the electrical current flows between the overlapped conductor strands when the conductors are transmitting electrical current.

  18. Computed tomography of cystic nerve root sleeve dilatation.

    PubMed

    Neave, V C; Wycoff, R R

    1983-10-01

    A case of cystic nerve root sleeve dilatation in the lumbar area associated with a chronic back pain syndrome is presented. Prominent computed tomography (CT) findings include: (a) rounded masses in the region of the foramina isodense with cerebrospinal fluid in the subarachnoid space; (b) associated asymmetry of epidural fat distribution; (c) enlargement of the neural foramina in axial sections with scalloped erosion of the adjacent posteriolateral vertebral body, pedicle, and pedicular-laminar junction with preservation of cortex and without bony sclerosis or infiltrative appearance; (d) prominent or ectatic dural sac with lack of usual epidural landmarks between the sac and vertebral body; and (e) multilevel abnormalities throughout the entire lumbar region. Myelographic and CT correlations are demonstrated with a review of the literature. A discussion of the various cystic abnormalities involving nerve root sheaths is undertaken in an attempt to clarify the confusing nomenclature applied to nerve root sleeve pathology.

  19. FLEXIBLE GEIGER COUNTER

    DOEpatents

    Richter, H.G.; Gillespie, A.S. Jr.

    1963-11-12

    A flexible Geiger counter constructed from materials composed of vinyl chloride polymerized with plasticizers or co-polymers is presented. The counter can be made either by attaching short segments of corrugated plastic sleeving together, or by starting with a length of vacuum cleaner hose composed of the above materials. The anode is maintained substantially axial Within the sleeving or hose during tube flexing by means of polystyrene spacer disks or an easily assembled polyethylene flexible cage assembly. The cathode is a wire spiraled on the outside of the counter. The sleeving or hose is fitted with glass end-pieces or any other good insulator to maintain the anode wire taut and to admit a counting gas mixture into the counter. Having the cathode wire on the outside of the counter substantially eliminates the objectional sheath effect of prior counters and permits counting rates up to 300,000 counts per minute. (AEC)

  20. Incidental gastric accessory spleen during laparoscopic sleeve gastrectomy.

    PubMed

    Almazeedi, Sulaiman; Alhaddad, Eliana; Al-Khithr, Talal; Alhunaidi, Mohammed

    2017-01-01

    Bariatric surgery has shown to produce the most predictable and tangible results for weight loss, with laparoscopic sleeve gastrectomy's being the most popular one of them. However, the occurrence of previously undiagnosed diseases can be encountered during bariatric operations. The work has been reported in line with the SCARE criteria. This is the case of a 54year old morbidly obese female, presenting to our hospital for a laparoscopic sleeve gastrectomy. During her procedure, it was discovered that she has an accessory spleen on the fundus of her stomach. The decision was made to resect it with the specimen of the stomach for histopathalogical examination. Incidental findings during routine bariatric surgery are a common occurance, and therefore prompt and effective intra-op management is key to the prognosis of the patient. Accessory spleens, although uncommon, tend to be asymptomatic. However, if undiagnosed, could present with dangerous consequences. Copyright © 2017. Published by Elsevier Ltd.

  1. Design of light guide sleeve on hyperspectral imaging system for skin diagnosis

    NASA Astrophysics Data System (ADS)

    Yan, Yung-Jhe; Chang, Chao-Hsin; Huang, Ting-Wei; Chiang, Hou-Chi; Wu, Jeng-Fu; Ou-Yang, Mang

    2017-08-01

    A hyperspectral imaging system is proposed for early study of skin diagnosis. A stable and high hyperspectral image quality is important for analysis. Therefore, a light guide sleeve (LGS) was designed for the embedded on a hyperspectral imaging system. It provides a uniform light source on the object plane with the determined distance. Furthermore, it can shield the ambient light from entering the system and increasing noise. For the purpose of producing a uniform light source, the LGS device was designed in the symmetrical double-layered structure. It has light cut structures to adjust distribution of rays between two layers and has the Lambertian surface in the front-end to promote output uniformity. In the simulation of the design, the uniformity of illuminance was about 91.7%. In the measurement of the actual light guide sleeve, the uniformity of illuminance was about 92.5%.

  2. Long term (7 or more years) outcomes of the sleeve gastrectomy: a meta-analysis.

    PubMed

    Clapp, Benjamin; Wynn, Matthew; Martyn, Colin; Foster, Chase; O'Dell, Montana; Tyroch, Alan

    2018-03-06

    The laparoscopic sleeve gastrectomy is now the most common bariatric operation in the United States and has become an established procedure in the armamentarium of the bariatric surgeon. However, this has happened without the strong support of long-term outcomes data, namely the rate of revision and durability of the weight loss. Newly published data from around the world are starting to show alarming trends in these 2 areas. This paper will examine the published and presented data with at least a 7-year follow-up. This is a meta-analysis on published data with at least 7 years of follow-up from the laparoscopic sleeve gastrectomy. Online published articles. We performed a meta-analysis of publications with at least 7 years of follow-up with the keywords "laparoscopic, bariatric, sleeve gastrectomy, sleeve, long-term, long, term, results, follow-up, follow up, conversion, 7 years, 8 years, 9 years, 10 years, 11 years." We queried the PubMed, MEDLINE, and ClinicalKey search engines, which included abstracts as well. The I 2 statistic was used to determine the heterogeneity across the studies. In presence of heterogeneity, a random effect model using the Dersimonian and Laird method was used to estimate the pooled estimates. The results were summarized using effect size along with a 95% confidence interval (CI). Meta-regression was also used to assess the effect of body mass index and follow-up years on the incidence of recidivism at ≥7 years. Nine cohort studies met the inclusion criteria, with a total of 2280 patients included initially. Only 652 patients had completed ≥7 years of follow-up. At ≥7 years, the long-term weight recidivism rate was estimated to be 27.8% (I 2 = .60%; 95% CI: 22.8%-32.7%) with a range of 14% to 37%. The overall revision rate was estimated to be 19.9% (I 2 = 93.8%; 95% CI: 11.3%-28.5%). This was broken down into 13.1% (I 2 = 93.8%; 95% CI: 5.6%-20.6%) due to weight regain (5 studies) and 2.9% (I 2 = 60.8%; 95% CI: 1%-4.9%) due to gastroesophageal reflux disease (5 studies). Based on available data up to the beginning of 2017, bariatric surgeons should be aware of the long-term outcomes of the sleeve gastrectomy, especially regarding revisions and weight regain. It is incumbent on the surgeon to make sure that bariatric patients are truly informed regarding the long-term results of the sleeve gastrectomy. Copyright © 2018 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  3. The New S-RAM Air Variable Compressor/Expander for Heat Pump and Waste Heat to Power Application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dehoff, Ryan R; Jestings, Lee; Conde, Ricardo

    S-RAM Dynamics (S-RAM) has designed an innovative heat pump system targeted for commercial and industrial applications. This new heat pump system is more efficient than anything currently on the market and utilizes air as the refrigerant instead of hydrofluorocarbon (HFC) refrigerants, leading to lower operating costs, minimal environmental costs or concerns, and lower maintenance costs. The heat pumps will be manufactured in the United States. This project was aimed at determining the feasibility of utilizing additive manufacturing to make the heat exchanger device for the new heat pump system. ORNL and S-RAM Dynamics collaborated on determining the prototype performance andmore » subsequently printing of the prototype using additive manufacturing. Complex heat exchanger designs were fabricated using the Arcam electron beam melting (EBM) powder bed technology using Ti-6Al-4V material. An ultrasonic welding system was utilized in order to remove the powder from the small openings of the heat exchanger. The majority of powder in the small chambers was removed, however, the amount of powder remaining in the heat exchanger was a function of geometry. Therefore, only certain geometries of heat exchangers could be fabricated. SRAM Dynamics evaluated a preliminary heat exchanger design. Although the results of the additive manufacturing of the heat exchanger were not optimum, a less complex geometry was demonstrated. A sleeve valve was used as a demonstration piece, as engine designs from S-RAM Dynamics require the engine to have a very high density. Preliminary designs of this geometry were successfully fabricated using the EBM technology.« less

  4. Development of a low-cost airborne ultrasound sensor for the detection of brick joints behind a wall painting.

    PubMed

    García-Diego, Fernando-Juan; Bravo, José María; Pérez-Miralles, Juan; Estrada, Héctor; Fernández-Navajas, Angel

    2012-01-01

    Non-destructive methods are of great interest for the analysis of cultural heritage. Among the different possible techniques, this paper presents a low cost prototype based on the emission and reception of airborne ultrasound without direct contact with the test specimen. We successfully performed a method test for the detection of brick joints under a XV th century Renaissance fresco of the Metropolitan Cathedral of the city of Valencia (Spain). Both laboratory and in situ results are in agreement. Using this prototype system, an early moisture detection system has been installed in the dome that supports the fresco. The result is encouraging and opens interesting prospects for future research.

  5. The Varied Impacts of Energy Storage and Photovoltaics on Fossil Fuel Emissions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Studarus, Karen E.; Thayer, Brandon L.; Barrett, Emily L.

    The emissions consequences of smart grid technologies can be significant but are not always intuitive. This is particularly true in the implementation of energy storage (ES) to enable the installation of solar photovoltaic (PV) systems. Using the web calculator at https://eqt.pnnl.gov and prototypical distribution feeders, this paper explores the COmore » $${_2}$$, SO$${_2}$$ and NO$${_x}$$ impacts of ES deployed with solar PV, where the energy storage system is operated to minimize load variation. Five regions of the country were explored using 15 prototypical distribution feeders and 2015 historical data. Impacts vary in direction, magnitude, and trend, and require a context-dependent screening method for faithful representation.« less

  6. DOE/NASA SIMS Prototype Solar System, no. 4. Part 1: Market analysis. Part 2: Modular manufacturing cost estimate

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The findings of the IIT Research Institute (IITRI) market study of the SIMS Prototype System 4, a hot water (DHW) system are documented. The feasibility of prepackaging currently available solar heating components into modular subsystems for site assembly is addressed. A documented design and installation procedure and a performance test report were prepared. The potential markets and applications for this particular system in the nonfederal market are profiled by assessing the needs and requirements of potential users and specifiers, by characterizing the nature of the market and the competitive environment, by identifying the barriers to commercial acceptance, and by estimating the size of the potential market.

  7. Performance of a Prototype Stationary Catadioptric Concentrating Photovoltaic Module

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lloyd, John V.; Kozodoy, Peter; Gladden, Christopher

    A stationary catadioptric concentrating photovoltaic module with aperture area over 100 cm2, geometric concentration of 180x, and collection within 60° of polar incidence was designed, prototyped, and characterized. The module performance followed modeling closely with a peak power conversion efficiency of 26% for direct irradiance. Tracking of the sun is accomplished via translational micro-tracking completely internal to the module, avoiding the cost and complexity of mechanical two-axis trackers that point towards the sun. This study demonstrates the potential for concentrating photovoltaic modules with significantly higher efficiency than industry standard silicon photovoltaic modules that could be installed in stationary configurations onmore » rooftops.« less

  8. Performance of a Prototype Stationary Catadioptric Concentrating Photovoltaic Module

    DOE PAGES

    Lloyd, John V.; Kozodoy, Peter; Gladden, Christopher; ...

    2018-03-28

    A stationary catadioptric concentrating photovoltaic module with aperture area over 100 cm2, geometric concentration of 180x, and collection within 60° of polar incidence was designed, prototyped, and characterized. The module performance followed modeling closely with a peak power conversion efficiency of 26% for direct irradiance. Tracking of the sun is accomplished via translational micro-tracking completely internal to the module, avoiding the cost and complexity of mechanical two-axis trackers that point towards the sun. This study demonstrates the potential for concentrating photovoltaic modules with significantly higher efficiency than industry standard silicon photovoltaic modules that could be installed in stationary configurations onmore » rooftops.« less

  9. Prototype to measure bracket debonding force in vivo

    PubMed Central

    Tonus, Jéssika Lagni; Manfroi, Fernanda Borguetti; Borges, Gilberto Antonio; Grigolo, Eduardo Correa; Helegda, Sérgio; Spohr, Ana Maria

    2017-01-01

    ABSTRACT Introduction: Material biodegradation that occurs in the mouth may interfere in the bonding strength between the bracket and the enamel, causing lower bond strength values in vivo, in comparison with in vitro studies. Objective: To develop a prototype to measure bracket debonding force in vivo and to evaluate, in vitro, the bond strength obtained with the prototype. Methods: A original plier (3M Unitek) was modified by adding one strain gauge directly connected to its claw. An electronic circuit performed the reading of the strain gauge, and the software installed in a computer recorded the values of the bracket debonding force, in kgf. Orthodontic brackets were bonded to the facial surface of 30 bovine incisors with adhesive materials. In Group 1 (n = 15), debonding was carried out with the prototype, while tensile bond strength testing was performed in Group 2 (n = 15). A universal testing machine was used for the second group. The adhesive remnant index (ARI) was recorded. Results: According to Student’s t test (α = 0.05), Group 1 (2.96 MPa) and Group 2 (3.08 MPa) were not significantly different. ARI score of 3 was predominant in the two groups. Conclusion: The prototype proved to be reliable for obtaining in vivo bond strength values for orthodontic brackets. PMID:28444011

  10. Air injection test on a Kaplan turbine: prototype - model comparison

    NASA Astrophysics Data System (ADS)

    Angulo, M.; Rivetti, A.; Díaz, L.; Liscia, S.

    2016-11-01

    Air injection is a very well-known resource to reduce pressure pulsation magnitude in turbines, especially on Francis type. In the case of large Kaplan designs, even when not so usual, it could be a solution to mitigate vibrations arising when tip vortex cavitation phenomenon becomes erosive and induces structural vibrations. In order to study this alternative, aeration tests were performed on a Kaplan turbine at model and prototype scales. The research was focused on efficiency of different air flow rates injected in reducing vibrations, especially at the draft tube and the discharge ring and also in the efficiency drop magnitude. It was found that results on both scales presents the same trend in particular for vibration levels at the discharge ring. The efficiency drop was overestimated on model tests while on prototype were less than 0.2 % for all power output. On prototype, air has a beneficial effect in reducing pressure fluctuations up to 0.2 ‰ of air flow rate. On model high speed image computing helped to quantify the volume of tip vortex cavitation that is strongly correlated with the vibration level. The hydrophone measurements did not capture the cavitation intensity when air is injected, however on prototype, it was detected by a sonometer installed at the draft tube access gallery.

  11. Electrical connector composite housing and method of making same

    DOEpatents

    Silva, Frank A.

    1979-01-01

    A sleeve-like insert of conductive elastomeric material of a type which serves as an internal shield in electrical connectors for connecting high voltage cables has an end portion folded upon itself, the enfolded portion being substantially permanently retained in its desired position by allowing insulative elastomeric material to fill apertures in the end portion and become bonded thereto in a void free manner, during molding of an insulating outer sleeve-like jacket about the insert.

  12. Compliant hydrodynamic fluid journal bearing

    NASA Technical Reports Server (NTRS)

    Warren, E. L. (Inventor)

    1985-01-01

    An air bearing structure is described that prevents destructive bending moments within the top foil. Welds are eliminated by mounting the top bearing foil in the bearing cartridge sleeve without using a space block. Tabs or pins at the end of the top bearing foil are restrained by slots or stops formed in the cartridge sleeve. These structural members are free to move in a direction normal to the shaft while being restrained from movement in the direction of shaft rotation.

  13. Caldron For High-Temperature Alloys

    NASA Technical Reports Server (NTRS)

    Geringer, Henry J.

    1989-01-01

    Induction-heated caldron melts high-temperature alloys. Prevents sort of contamination of melts occurring during arc melting in ceramic crucibles. Liquefies 200 grams of solid metal components of alloy like niobium aluminum and makes alloy homogeneous in less than 3 minutes. Plugged sleeve constitutes main body of caldron. Coolant flows through sleeve to prevent it from melting. Mandrel-wound induction coils adjusted to tune source of power. Also serves as mold for casting alloys into such shapes as bars.

  14. Sealed fiber-optic bundle feedthrough

    DOEpatents

    Tanner, Carol E.

    2002-01-01

    A sealed fiber-optic bundle feedthrough by which a multitude of fiber-optic elements may be passed through an opening or port in a wall or structure separating two environments at different pressures or temperatures while maintaining the desired pressure or temperature in each environment. The feedthrough comprises a rigid sleeve of suitable material, a bundle of individual optical fibers, and a resin-based sealing material that bonds the individual optical fibers to each other and to the rigid sleeve.

  15. Cryogenic support member

    DOEpatents

    Niemann, Ralph C.; Gonczy, John D.; Nicol, Thomas H.

    1987-01-01

    A cryogenic support member is comprised of a non-metallic rod having a depression in at least one end and a metallic end connection assembled to the rod. The metallic end connection comprises a metallic plug which conforms to the shape and is disposed in the depression and a metallic sleeve is disposed over the rod and plug. The plug and the sleeve are shrink-fitted to the depression in the rod to form a connection good in compression, tension and bending.

  16. Sleeve gastrectomy leads to easy management of hormone replacement therapy and good weight loss in patients treated for craniopharyngioma.

    PubMed

    Trotta, Manuela; Da Broi, Joël; Salerno, Angelo; Testa, Rosa M; Marinari, Giuseppe M

    2017-03-01

    The aim of this study is to investigate the effects of sleeve gastrectomy on hormone replacement therapy and on hypothalamic obesity in patients affected by craniopharyngioma with post-surgical pan-hypopituitarism. A retrospective review of three patients, treated for hypothalamic obesity with laparoscopic sleeve gastrectomy, who have previously undergone surgery for craniopharyngioma in their childhood, was done. Patients' mean age and BMI were 22.3 years (range 21-24) and 49.2 kg/m 2 (range 41.6-58.1), respectively. The mean time of delay between neurosurgery and bariatric surgery was 12.3 years (range 6-16). There were no major complications or deaths. At 24 months follow-up, the mean BMI was 35.3 kg/m 2 (range 31.2-40.6). No hydrocortisone and sex steroids dose changes were observed, while levothyroxine was decreased in two patients. Growth hormone replacement therapy was increased in two patients, whereas it was started in one patient. Desmopressin was significantly decreased in all of them. Patients with surgically induced pan-hypopituitarism after craniopharyngioma who become obese, can expect good results from sleeve gastrectomy: this procedure does not have significant negative effects on hormone substitution and leads to a good stabilization of body weight in a mid-term follow-up.

  17. The Surgical Management of Complex Fistulas After Sleeve Gastrectomy.

    PubMed

    Nguyen, David; Dip, Fernando; Hendricks, LéShon; Lo Menzo, Emanuele; Szomstein, Samuel; Rosenthal, Raul

    2016-02-01

    Laparoscopic sleeve gastrectomy (LSG) is gaining acceptance as the preferred option for treating obesity. Risks of leak and subsequent fistula after sleeve gastrectomy still present significant concerns in clinical practice. This current series presents unusual fistulas post-LSG and their surgical management. The series presents chronic leaks that have progressed into fistulas. Three patients with fistulas are presented: gastrocolic, gastropleural, and gastrosplenic. Surgical intervention was warranted in all cases with en-bloc resection of the fistula with subtotal gastrectomy and Roux-en-Y esophagojejunostomy reconstruction. A subtotal colectomy with ileo-descending colon anastomosis was additionally necessary in the gastrocolic patient. The patients with the gastropleural and gastrosplenic fistulas were discharged home on postoperative Day 6 and Day 7, respectively. The patient with the gastrocolic fistula had an extended postoperative hospital course and was discharged home on postoperative Day 35. All cases were negative for staple line leaks. To date, the fistulas healed with no recurrence. En-bloc resection of the fistula with proximal gastrectomy and Roux-en-Y esophagojejunostomy (PGRYEJ) is a surgical option to treat chronic staple line leakage when non-operative therapy is rendered ineffective. Adequate preoperative planning with optimization of nutritional status and control of local and systemic sepsis is paramount for ultimate success. A symptomatic leak requires immediate operation regardless of the time interval between the primary sleeve operation and appearance of the leak.

  18. CT-Guided Percutaneous Drainage of Infected Collections Due to Gastric Leak After Sleeve Gastrectomy for Morbid Obesity: Initial Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelogrigoris, M., E-mail: kelogre.mic@hotmail.com; Sotiropoulou, E.; Stathopoulos, K.

    This study was designed to evaluate the efficacy and safety of computed tomography (CT)-guided drainage in treating infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity. From January 2007 to June 2009, 21 patients (9 men and 12 women; mean age, 39.2 (range, 26-52) years) with infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity underwent image-guided percutaneous drainage. All procedures were performed using CT guidance and 8- to 12-Fr pigtail drainage catheters. Immediate technical success was achieved in all 21 infected collections. In 18 of 21 collections, we obtained progressive shrinkagemore » of the collection with consequent clinical success (success rate 86%). In three cases, the abdominal fluid collection was not resolved, and the patients were reoperated. Among the 18 patients who avoided surgery, 2 needed replacement of the catheter due to obstruction. No major complications occurred during the procedure. The results of our study support that CT-guided percutaneous drainage is an effective and safe method to treat infected abdominal fluid collections due to gastric leak in patients who had previously underwent laparoscopic sleeve gastrectomy for morbid obesity. It may be considered both as a preparatory step for surgery and a valuable alternative to open surgery. Failure of the procedure does not, however, preclude a subsequent surgical operation.« less

  19. Data Transmission System For A Downhole Component

    DOEpatents

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David; Dahlgren, Scott; Sneddon, Cameron; Fox, Joe; Briscoe, Michael

    2005-01-18

    The invention is a system for transmitting data through a string of downhole components. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string. Each component has a first and second end, with a first communication element located at the first end and a second communication element located at the second end. Each communication element includes a first contact and a second contact. The system also includes a coaxial cable running between the first and second communication elements, the coaxial cable having a conductive tube and a conductive core within it. The system also includes a first and second connector for connecting the first and second communication elements respectively to the coaxial cable. Each connector includes a conductive sleeve, lying concentrically within the conductive tube, which fits around and makes electrical contact with the conductive core. The conductive sleeve is electrically isolated from the conductive tube. The conductive sleeve of the first connector is in electrical contact with the first contact of the first communication element, the conductive sleeve of the second connector is in electrical contact with the first contact of the second communication element, and the conductive tube is in electrical contact with both the second contact of the first communication element and the second contact of the second communication element.

  20. Data transmission system for a downhole component

    DOEpatents

    Hall, David R.; Hall, Jr., Tracy H.; Pixton, David S.; Dahlgren, Scott Steven; Fox, Joe; Sneddon, Cameron; Briscoe, Michael A.

    2006-05-09

    The invention is a system for transmitting data through a string of downhole components. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string. Each component has a first and second end, with a first communication element located at the first end and a second communication element located at the second end. Each communication element includes a first contact and a second contact. The system also includes a coaxial cable running between the first and second communication elements, the coaxial cable having a conductive tube and a conductive core within it. The system also includes a first and second connector for connecting the first and second communication elements respectively to the coaxial cable. Each connector includes a conductive sleeve, lying concentrically within the conductive tube, which fits around and makes electrical contact with the conductive core. The conductive sleeve is electrically isolated from the conductive tube. The conductive sleeve of the first connector is in electrical contact with the first contact of the first communication element, the conductive sleeve of the second connector is in electrical contact with the first contact of the second communication element, and the conductive tube is in electrical contact with both the second contact of the first communication element and the second contact of the second communication element.

  1. The Effects of Bougie Diameters on Tissue Oxygen Levels After Sleeve Gastrectomy: A Randomized Experimental Trial

    PubMed

    Konca, Can; Yılmaz, Ali Abbas; Çelik, Süleyman Utku; Kayılıoğlu, Selami Ilgaz; Paşaoğlu, Özge Tuğçe; Ceylan, Halil Arda; Genç, Volkan

    2018-05-29

    Staple-line leak is the most frightening complication of laparoscopic sleeve gastrectomy and several predisposing factors such as using improper staple sizes regardless of gastric wall thickness, narrower bougie diameter and ischemia of the staple line are asserted. To evaluate the effects of different bougie diameters on tissue oxygen partial pressure at the esophagogastric junction after sleeve gastrectomy. A randomized and controlled animal experiment with 1:1:1:1 allocation ratio. Thirty-two male Wistar Albino rats were randomly divided into 4 groups of 8 each. While 12-Fr bougies were used in groups 1 and 3, 8-Fr bougies were used in groups 2 and 4. Fibrin sealant application was also carried out around the gastrectomy line after sleeve gastrectomy in groups 3 and 4. Burst pressure of gastrectomy line, tissue oxygen partial pressure and hydroxyproline levels at the esophagogastric junction were measured and compared among groups. Mortality was detected in 2 out of 32 rats (6.25%) and one of them was in group 2 and the cause of this mortality was gastric leak. Gastric leak was detected in 2 out of 32 rats (6.25%). There was no significant difference in terms of burst pressures, tissue oxygen partial pressure and tissue hydroxyproline levels among the 4 groups. The use of narrower bougie along with fibrin sealant has not had a negative effect on tissue perfusion and wound healing.

  2. Long term monitoring of the optical background in the Capo Passero deep-sea site with the NEMO tower prototype

    NASA Astrophysics Data System (ADS)

    Adrián-Martínez, S.; Aiello, S.; Ameli, F.; Anghinolfi, M.; Ardid, M.; Barbarino, G.; Barbarito, E.; Barbato, F. C. T.; Beverini, N.; Biagi, S.; Biagioni, A.; Bouhadef, B.; Bozza, C.; Cacopardo, G.; Calamai, M.; Calì, C.; Calvo, D.; Capone, A.; Caruso, F.; Ceres, A.; Chiarusi, T.; Circella, M.; Cocimano, R.; Coniglione, R.; Costa, M.; Cuttone, G.; D'Amato, C.; D'Amico, A.; De Bonis, G.; De Luca, V.; Deniskina, N.; De Rosa, G.; di Capua, F.; Distefano, C.; Enzenhöfer, A.; Fermani, P.; Ferrara, G.; Flaminio, V.; Fusco, L. A.; Garufi, F.; Giordano, V.; Gmerk, A.; Grasso, R.; Grella, G.; Hugon, C.; Imbesi, M.; Kulikovskiy, V.; Lahmann, R.; Larosa, G.; Lattuada, D.; Leismüller, K. P.; Leonora, E.; Litrico, P.; Llorens Alvarez, C. D.; Lonardo, A.; Longhitano, F.; Lo Presti, D.; Maccioni, E.; Margiotta, A.; Marinelli, A.; Martini, A.; Masullo, R.; Migliozzi, P.; Migneco, E.; Miraglia, A.; Mollo, C. M.; Mongelli, M.; Morganti, M.; Musico, P.; Musumeci, M.; Nicolau, C. A.; Orlando, A.; Orzelli, A.; Papaleo, R.; Pellegrino, C.; Pellegriti, M. G.; Perrina, C.; Piattelli, P.; Pugliatti, C.; Pulvirenti, S.; Raffaelli, F.; Randazzo, N.; Real, D.; Riccobene, G.; Rovelli, A.; Saldaña, M.; Sanguineti, M.; Sapienza, P.; Sciacca, V.; Sgura, I.; Simeone, F.; Sipala, V.; Speziale, F.; Spitaleri, A.; Spurio, M.; Stellacci, S. M.; Taiuti, M.; Terreni, G.; Trasatti, L.; Trovato, A.; Ventura, C.; Vicini, P.; Viola, S.; Vivolo, D.

    2016-02-01

    The NEMO Phase-2 tower is the first detector which was operated underwater for more than 1 year at the "record" depth of 3500 m. It was designed and built within the framework of the NEMO (NEutrino Mediterranean Observatory) project. The 380 m high tower was successfully installed in March 2013 80 km offshore Capo Passero (Italy). This is the first prototype operated on the site where the Italian node of the KM3NeT neutrino telescope will be built. The installation and operation of the NEMO Phase-2 tower has proven the functionality of the infrastructure and the operability at 3500 m depth. A more than 1 year long monitoring of the deep water characteristics of the site has been also provided. In this paper the infrastructure and the tower structure and instrumentation are described. The results of long term optical background measurements are presented. The rates show stable and low baseline values, compatible with the contribution of ^{40}K light emission, with a small percentage of light bursts due to bioluminescence. All these features confirm the stability and good optical properties of the site.

  3. The GINGER project and status of the GINGERino prototype at LNGS

    NASA Astrophysics Data System (ADS)

    Ortolan, A.; Belfi, J.; Bosi, F.; Di Virgilio, A.; Beverini, N.; Carelli, G.; Maccioni, E.; Santagata, R.; Simonelli, A.; Beghi, A.; Cuccato, D.; Donazzan, A.; Naletto, G.

    2016-05-01

    GINGER (Gyroscopes IN GEneral Relativity) is a proposal for measuring in a ground-based laboratory the Lense-Thirring effect, known also as inertial frame dragging, that is predicted by General Relativity, and is induced by the rotation of a massive source. GINGER will consist in an array of at least three square ring lasers, mutually orthogonal, with about 6-10 m side, and located in a deep underground site, possibly the INFN - National Laboratories of Gran Sasso. The tri-axial design will provide a complete estimation of the laboratory frame angular velocity, to be compared with the Earths rotation estimate provided by IERS with respect the fixed stars frame. Large-size ring lasers have already reached a very high sensitivity, allowing for relevant geodetic measurements. The accuracy required for Lense-Thirring effect measurement is higher than 10-14 rad/s and therefore Earth angular velocity must be measured within one part in 10-9. A 3.6 m side, square ring laser, called GINGERino, has been recently installed inside the Gran Sasso underground laboratories in order to qualify the site for a future installation of GINGER. We discuss the current status of the experimental work, and in particular of the GINGERino prototype.

  4. The beam diagnostic instruments in Beijing radioactive ion-beam facilities isotope separator on-line

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, Y., E-mail: yjma@ciae.ac.cn; Cui, B.; Ma, R.

    The beam diagnostic instruments for Beijing Radioactive Ion-beam Facilities Isotope Separator On-Line are introduced [B. Q. Cui, Z. H. Peng, Y. J. Ma, R. G. Ma, B. Tang, T. Zhang, and W. S. Jiang, Nucl. Instrum. Methods 266, 4113 (2008); T. J. Zhang, X. L. Guan, and B. Q. Cui, in Proceedings of APAC 2004, Gyeongju, Korea, 2004, http://www.jacow.org , p. 267]. For low intensity ion beam [30–300 keV/1 pA–10 μA], the beam profile monitor, the emittance measurement unit, and the analyzing slit will be installed. For the primary proton beam [100 MeV/200 μA], the beam profile scanner will bemore » installed. For identification of the nuclide, a beam identification unit will be installed. The details of prototype of the beam diagnostic units and some experiment results will be described in this article.« less

  5. Intelligent electrical harness connector assembly using Bell Helicopter Textron's 'Wire Harness Automated Manufacturing System'

    NASA Astrophysics Data System (ADS)

    Springer, D. W.

    Bell Helicopter Textron, Incorporated (BHTI) installed two Digital Equipment Corporation PDP-11 computers and an American Can Inc. Ink Jet printer in 1980 as the cornerstone of the Wire Harness Automated Manufacturing System (WHAMS). WHAMS is based upon the electrical assembly philosophy of continuous filament harness forming. This installation provided BHTI with a 3 to 1 return-on-investment by reducing wire and cable identification cycle time by 80 percent and harness forming, on dedicated layout tooling, by 40 percent. Yet, this improvement in harness forming created a bottle neck in connector assembly. To remove this bottle neck, BHTI has installed a prototype connector assembly cell that integrates the WHAMS' data base and innovative computer technologies to cut harness connector assembly cycle time. This novel connector assembly cell uses voice recognition, laser identification, and animated computer graphics to help the electrician in the correct assembly of harness connectors.

  6. Contingency Contractor Optimization Phase 3 Sustainment Platform Requirements - Contingency Contractor Optimization Tool - Prototype

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Durfee, Justin David; Frazier, Christopher Rawls; Bandlow, Alisa

    Sandia National Laboratories (Sandia) is in Phase 3 Sustainment of development of a prototype tool, currently referred to as the Contingency Contractor Optimization Tool - Prototype (CCOTP), under the direction of OSD Program Support. CCOT-P is intended to help provide senior Department of Defense (DoD) leaders with comprehensive insight into the global availability, readiness and capabilities of the Total Force Mix. The CCOT-P will allow senior decision makers to quickly and accurately assess the impacts, risks and mitigating strategies for proposed changes to force/capabilities assignments, apportionments and allocations options, focusing specifically on contingency contractor planning. During Phase 2 of themore » program, conducted during fiscal year 2012, Sandia developed an electronic storyboard prototype of the Contingency Contractor Optimization Tool that can be used for communication with senior decision makers and other Operational Contract Support (OCS) stakeholders. Phase 3 used feedback from demonstrations of the electronic storyboard prototype to develop an engineering prototype for planners to evaluate. Sandia worked with the DoD and Joint Chiefs of Staff strategic planning community to get feedback and input to ensure that the engineering prototype was developed to closely align with future planning needs. The intended deployment environment was also a key consideration as this prototype was developed. Initial release of the engineering prototype was done on servers at Sandia in the middle of Phase 3. In 2013, the tool was installed on a production pilot server managed by the OUSD(AT&L) eBusiness Center. The purpose of this document is to specify the CCOT-P engineering prototype platform requirements as of May 2016. Sandia developed the CCOT-P engineering prototype using common technologies to minimize the likelihood of deployment issues. CCOT-P engineering prototype was architected and designed to be as independent as possible of the major deployment components such as the server hardware, the server operating system, the database, and the web server. This document describes the platform requirements, the architecture, and the implementation details of the CCOT-P engineering prototype.« less

  7. Borehole prototype for seismic high-resolution exploration

    NASA Astrophysics Data System (ADS)

    Giese, Rüdiger; Jaksch, Katrin; Krauß, Felix; Krüger, Kay; Groh, Marco; Jurczyk, Andreas

    2014-05-01

    Target reservoirs for the exploitation of hydrocarbons or hot water for geothermal energy supply can comprise small layered structures, for instance thin layers or faults. The resolution of 2D and 3D surface seismic methods is often not sufficient to determine and locate these structures. Borehole seismic methods like vertical seismic profiling (VSP) and seismic while drilling (SWD) use either receivers or sources within the borehole. Thus, the distance to the target horizon is reduced and higher resolution images of the geological structures can be achieved. Even these methods are limited in their resolution capabilities with increasing target depth. To localize structures more accuracy methods with higher resolution in the range of meters are necessary. The project SPWD -- Seismic Prediction While Drilling aims at s the development of a borehole prototype which combines seismic sources and receivers in one device to improve the seismic resolution. Within SPWD such a prototype has been designed, manufactured and tested. The SPWD-wireline prototype is divided into three main parts. The upper section comprises the electronic unit. The middle section includes the upper receiver, the upper clamping unit as well as the source unit and the lower clamping unit. The lower section consists of the lower receiver unit and the hydraulic unit. The total length of the prototype is nearly seven meters and its weight is about 750 kg. For focusing the seismic waves in predefined directions of the borehole axis the method of phased array is used. The source unit is equipped with four magnetostrictive vibrators. Each can be controlled independently to get a common wave front in the desired direction of exploration. Source signal frequencies up to 5000 Hz are used, which allows resolutions up to one meter. In May and September 2013 field tests with the SPWD-wireline prototype have been carried out at the KTB Deep Crustal Lab in Windischeschenbach (Bavaria). The aim was to proof the pressure-tightness and the functionality of the hydraulic system components of the borehole device. To monitor the prototype four cameras and several moisture sensors were installed along the source and receiver units close to the extendable coupling stamps where an infiltration of fluid is most probably. The tests lasted about 48 hours each. It was possible to extend and to retract the coupling stamps of the prototype up to a depth of 2100 m. No infiltration of borehole fluids in the SPWD-tool was observed. In preparation of the acoustic calibration measurements in the research and education mine of the TU Bergakademie Freiberg seismic sources and receivers as well as the recording electronic devices were installed in the SPWD-wireline prototype at the GFZ. Afterwards, the SPWD-borehole device was transported to the GFZ-Underground-Lab and preliminary test measurements to characterize the radiation pattern characteristics have been carried out in the newly drilled vertical borehole in December 2013. Previous measurements with a laboratory borehole prototype have demonstrated a dependency of the radiated seismic energy from the predefined amplification direction, the wave type and the signal frequencies. SPWD is funded by the German Federal Environment Ministry

  8. Sun protective behaviors and vitamin D levels in the US population: NHANES 2003–2006

    PubMed Central

    Linos, Eleni; Keiser, Elizabeth; Kanzler, Matthew; Sainani, Kristin L.; Lee, Wayne; Vittinghoff, Eric; Chren, Mary-Margaret; Tang, Jean Y.

    2013-01-01

    Background Sun protection is recommended for skin cancer prevention, yet little is known about the role of sun protection on vitamin D levels. Our aim was to investigate the relationship between different types of sun protective behaviors and serum 25(OH)D levels in the general US population. Methods Cross-sectional, nationally representative survey of 5,920 adults aged 18–60 years in the US National Health and Nutrition Examination Survey 2003–2006. We analyzed questionnaire responses on sun protective behaviors: staying in the shade, wearing long sleeves, wearing a hat, using sunscreen and SPF level. Analyses were adjusted for multiple confounders of 25(OH)D levels and stratified by race. Our primary outcome measures were serum 25(OH)D levels (ng/ml) measured by radioimmunoassay and vitamin D deficiency, defined as 25(OH)D levels <20 ng/ml. Results Staying in the shade and wearing long sleeves were significantly associated with lower 25(OH)D levels. Subjects who reported frequent use of shade on a sunny day had −3.5 ng/ml (ptrend < 0.001) lower 25(OH)D levels compared to subjects who reported rare use. Subjects who reported frequent use of long sleeves had −2.2 ng/ml (ptrend = 0.001) lower 25(OH)D levels. These associations were strongest for whites, and did not reach statistical significance among Hispanics or blacks. White participants who reported frequently staying in the shade or wearing long sleeves had double the odds of vitamin D deficiency compared with those who rarely did so. Neither wearing a hat nor using sunscreen was associated with low 25(OH)D levels or vitamin D deficiency. Conclusions White individuals who protect themselves from the sun by seeking shade or wearing long sleeves may have lower 25(OH)D levels and be at risk for vitamin D deficiency. Frequent sunscreen use does not appear to be linked to vitamin D deficiency in this population. PMID:22045154

  9. pH monitoring of gastro-oesophageal reflux before and after laparoscopic sleeve gastrectomy.

    PubMed

    Thereaux, J; Barsamian, C; Bretault, M; Dusaussoy, H; Lamarque, D; Bouillot, J-L; Czernichow, S; Carette, C

    2016-03-01

    Gastro-oesophageal reflux disease (GORD) is a common obesity-related co-morbidity that is assessed objectively by 24-h pH monitoring. Some concerns have been raised regarding the risk of de novo GORD or exacerbation of pre-existing GORD after laparoscopic sleeve gastrectomy. Here, 24-h pH monitoring was used to assess the influence of laparoscopic sleeve gastrectomy on postoperative GORD in obese patients with or without preoperative GORD. From July 2012 to September 2014, all patients scheduled for laparoscopic sleeve gastrectomy were invited to participate in a prospective follow-up. Patients who underwent preoperative 24-h pH monitoring were asked to repeat the examination 6 months after operation. GORD was defined as an oesophageal pH < 4 for at least 4·2 per cent of the total time recorded. Of 89 patients, 76 had preoperative pH monitoring for GORD evaluation and 50 had postoperative reassessment. Patients without (group 1, 29 patients) or with (group 2, 21 patients) preoperative GORD were similar regarding age, sex ratio and body mass index. In group 1, the median (i.q.r.) total time at pH < 4 was significantly higher after surgery than before: 5·6 (2·5-9·5) versus 1·6 (0·7-2·9) per cent (P < 0·001). Twenty of the 29 patients experienced de novo GORD as determined by 24-h pH monitoring (P < 0·001). In group 2, total time at pH < 4 after surgery was no different from the preoperative value: 5·9 (3·9-10·7) versus 7·7 (5·2-10·3) per cent (P = 0·296). Laparoscopic sleeve gastrectomy was associated with de novo GORD in over two-thirds of patients, but did not seem to exacerbate existing GORD. © 2016 BJS Society Ltd Published by John Wiley & Sons Ltd.

  10. Experimental feasibility study of radial injection cooling of three-pad radial air foil bearings

    NASA Astrophysics Data System (ADS)

    Shrestha, Suman K.

    Air foil bearings use ambient air as a lubricant allowing environment-friendly operation. When they are designed, installed, and operated properly, air foil bearings are very cost effective and reliable solution to oil-free turbomachinery. Because air is used as a lubricant, there are no mechanical contacts between the rotor and bearings and when the rotor is lifted off the bearing, near frictionless quiet operation is possible. However, due to the high speed operation, thermal management is one of the very important design factors to consider. Most widely accepted practice of the cooling method is axial cooling, which uses cooling air passing through heat exchange channels formed underneath the bearing pad. Advantage is no hardware modification to implement the axial cooling because elastic foundation structure of foil bearing serves as a heat exchange channels. Disadvantage is axial temperature gradient on the journal shaft and bearing. This work presents the experimental feasibility study of alternative cooling method using radial injection of cooling air directly on the rotor shaft. The injection speeds, number of nozzles, location of nozzles, total air flow rate are important factors determining the effectiveness of the radial injection cooling method. Effectiveness of the radial injection cooling was compared with traditional axial cooling method. A previously constructed test rig was modified to accommodate a new motor with higher torque and radial injection cooling. The radial injection cooling utilizes the direct air injection to the inlet region of air film from three locations at 120° from one another with each location having three axially separated holes. In axial cooling, a certain axial pressure gradient is applied across the bearing to induce axial cooling air through bump foil channels. For the comparison of the two methods, the same amount of cooling air flow rate was used for both axial cooling and radial injection. Cooling air flow rate was referenced to the rotor surface speed for radial injection cooling. The mass flow rates for the radial injection were 0.032, 0.0432, 0.054 and 0.068 Kg/min, which result in average injection speed of 150, 200, 250 and 300% of rotor surface speed. Several thermocouples were attached at various circumferential directions of the bearing sleeve, two plenums, bearing holder and ball bearing housings to collect the temperature data of the bearing at 30krpm under 10lb of load. Both axial cooling and radial injection are effective cooling mechanism and effectiveness of both cooling methods is directly proportional to the total mass flow rates. However, axial cooling is slightly more efficient in controlling the average temperature of the bearing sleeve, but results in higher thermal gradient of the shaft along the axial direction and also higher thermal gradient of the bearing sleeve along the circumferential direction compared to the radial injection cooling. The smaller thermal gradient of the radial injection cooling is due to the direct cooling effect of the shaft by impinging jets. While the axial cooling has an effect on only the bearing, the radial injection has a cooling effect on both the bearing sleeve and shaft. It is considered the radial injection cooling needs to be further optimized in terms of number of injection holes and their locations.

  11. Development of in-vessel components of the microfission chamber for ITER.

    PubMed

    Ishikawa, M; Kondoh, T; Ookawa, K; Fujita, K; Yamauchi, M; Hayakawa, A; Nishitani, T; Kusama, Y

    2010-10-01

    Microfission chambers (MFCs) will measure the total neutron source strength in ITER. The MFCs will be installed behind blanket modules in the vacuum vessel (VV). Triaxial mineral insulated (MI) cables will carry signals from the MFCs. The joint connecting triaxial MI cables in the VV must be considered because the MFCs and the MI cables will be installed separately at different times. Vacuum tight triaxial connector of the MI cable has been designed and a prototype has been constructed. Performance tests indicate that the connector can be applied to the ITER environment. A small bending-radius test of the MI cable indicates no observed damage at a curvature radius of 100 mm.

  12. Development of in-vessel components of the microfission chamber for ITER1

    PubMed Central

    Ishikawa, M.; Kondoh, T.; Ookawa, K.; Fujita, K.; Yamauchi, M.; Hayakawa, A.; Nishitani, T.; Kusama, Y.

    2010-01-01

    Microfission chambers (MFCs) will measure the total neutron source strength in ITER. The MFCs will be installed behind blanket modules in the vacuum vessel (VV). Triaxial mineral insulated (MI) cables will carry signals from the MFCs. The joint connecting triaxial MI cables in the VV must be considered because the MFCs and the MI cables will be installed separately at different times. Vacuum tight triaxial connector of the MI cable has been designed and a prototype has been constructed. Performance tests indicate that the connector can be applied to the ITER environment. A small bending-radius test of the MI cable indicates no observed damage at a curvature radius of 100 mm. PMID:21033834

  13. KM3NeT tower data acquisition and data transport electronics

    NASA Astrophysics Data System (ADS)

    Nicolau, C. A.; Ameli, F.; Biagioni, A.; Capone, A.; Frezza, O.; Lonardo, A.; Masullo, R.; Mollo, C. M.; Orlando, A.; Simeone, F.; Vicini, P.

    2016-04-01

    In the framework of the KM3Net European project, the production stage of a large volume underwater neutrino telescope has started. The forthcoming installation includes 8 towers and 24 strings, that will be installed 100 km off-shore Capo Passero (Italy) at 3500 m depth. The KM3NeT tower, whose layout is strongly based on the NEMO Phase-2 prototype tower deployed in March 2013, has been re-engineered and partially re-designed in order to optimize production costs, power consumption, and usability. This contribution gives a description of the main electronics, including front-end, data transport and clock distribution system, of the KM3NeT tower detection unit.

  14. USAF solar thermal applications case studies

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The potential of solar energy technologies to meet mission related applications for process heat was investigated. The reduction of the dependence of military installations on fossil fuels by promoting the use of more abundant resources where liquid hydrocarbons and natural gas are now used is examined. The evaluation and utilization of renewable energy systems to provide process heat and space heating are emphasized. The application of thermal energy systems is divided into four steps: (1) investigation of the potential operational cost effectiveness of selected thermal technologies; (2) selection of a site and preliminary design of point focussing solar thermal plant; (3) construction and test of an engineering prototype; and (4) installation and operation of a solar thermal energy plant.

  15. Clinical Issues-May 2016.

    PubMed

    Van Wicklin, Sharon A

    2016-05-01

    Variations in documenting surgical wound classification Key words: surgical wound classification, clean, clean-contaminated, contaminated, dirty. Wearing long-sleeved jackets while preparing and packaging items for sterilization Key words: long-sleeved jackets, organic material, sterile processing. Endoscopic transmission of prions Key words: prions, high-risk tissue, low-risk tissue, Creutzfeldt-Jakob disease (CJD), variant Creutzfeldt-Jakob disease (vCJD). Wearing gloves when handling flexible endoscopes Key words: gloves, low-protein, powder-free, natural rubber latex gloves, latex-free gloves. Copyright © 2016 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  16. Open end protection for solid oxide fuel cells

    DOEpatents

    Zafred, Paolo R.; Dederer, Jeffrey T.; Tomlins, Gregory W.; Toms, James M.; Folser, George R.; Schmidt, Douglas S.; Singh, Prabhakar; Hager, Charles A.

    2001-01-01

    A solid oxide fuel cell (40) having a closed end (44) and an open end (42) operates in a fuel cell generator (10) where the fuel cell open end (42) of each fuel cell contains a sleeve (60, 64) fitted over the open end (42), where the sleeve (60, 64) extends beyond the open end (42) of the fuel cell (40) to prevent degradation of the interior air electrode of the fuel cell by fuel gas during operation of the generator (10).

  17. Fixture For Drilling And Tapping A Curved Workpiece

    NASA Technical Reports Server (NTRS)

    Espinosa, P. S.; Lockyer, R. T.

    1992-01-01

    Simple fixture guides drilling and tapping of holes in prescribed locations and orientations on workpiece having curved surface. Tool conceived for use in reworking complexly curved helicopter blades made of composite materials. Fixture is block of rigid foam with epoxy filler, custom-fitted to surface contour, containing bushings and sleeves at drilling and tapping sites. Bushings changed, so taps and drills of various sizes accommodated. In use, fixture secured to surface by hold-down bolts extending through sleeves and into threads in substrate.

  18. Fuel or irradiation subassembly

    DOEpatents

    Seim, O.S.; Hutter, E.

    1975-12-23

    A subassembly for use in a nuclear reactor is described which incorporates a loose bundle of fuel or irradiation pins enclosed within an inner tube which in turn is enclosed within an outer coolant tube and includes a locking comb consisting of a head extending through one side of the inner sleeve and a plurality of teeth which extend through the other side of the inner sleeve while engaging annular undercut portions in the bottom portion of the fuel or irradiation pins to prevent movement of the pins.

  19. FUEL ELEMENT FOR A NUCLEAR REACTOR

    DOEpatents

    Davidson, J.K.

    1963-11-19

    A fuel element structure particularly useful in high temperature nuclear reactors is presented. Basically, the structure comprises two coaxial graphite sleeves integrally joined together by radial fins. Due to the high structural strength of graphite at high temperatures and the rigidity of this structure, nuclear fuel encased within the inner sleeve in contiguous relation therewith is supported and prevented from expanding radially at high temperatures. Thus, the necessity of relying on the usual cladding materials with relatively low temperature limitations for structural strength is removed. (AEC)

  20. Recent Progress on High-Current SRF Cavities at Jlab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robert Rimmer, William Clemens, James Henry, Peter Kneisel, Kurt Macha, Frank Marhauser, Larry Turlington, Haipeng Wang, Daniel Forehand

    2010-05-01

    JLab has designed and fabricated several prototype SRF cavities with cell shapes optimized for high current beams and with strong damping of unwanted higher order modes. We report on the latest test results of these cavities and on developments of concepts for new variants optimized for particular applications such as light sources and high-power proton accelerators, including betas less than one. We also report on progress towards a first beam test of this design in the recirculation loop of the JLab ERL based FEL. With growing interest worldwide in applications of SRF for high-average power electron and hadron machines, amore » practical test of these concepts is highly desirable. We plan to package two prototype cavities in a de-mountable cryomodule for temporary installation into the JLab FEL for testing with RF and beam. This will allow verification of all critical design and operational parameters paving the way to a full-scale prototype cryomodule.« less

Top