Sample records for instrument development process

  1. Mars Miniature Science Instruments

    NASA Technical Reports Server (NTRS)

    Kim, Soon Sam; Hayati, Samad; Lavery, David; McBrid, Karen

    2006-01-01

    For robotic Mars missions, all the science information is gathered through on-board miniature instruments that have been developed through many years of R&D. Compared to laboratory counterparts, the rover instruments require miniaturization, such as low mass (1-2 kg), low power (> 10 W) and compact (1-2 liter), yet with comparable sensitivity. Since early 1990's, NASA recognized the need for the miniature instruments and launched several instrument R&D programs, e.g., PIDDP (Planetary Instrument Definition and Development). However, until 1998, most of the instrument R&D programs supported only up to a breadboard level (TRL 3, 4) and there is a need to carry such instruments to flight qualifiable status (TU 5, 6) to respond to flight AOs (Announcement of Opportunity). Most of flight AOs have only limited time and financial resources, and can not afford such instrument development processes. To bridge the gap between instrument R&D programs and the flight instrument needs, NASA's Mars Technology Program (MTP) created advanced instrumentation program, Mars Instrument Development Project (MIDP). MIDP candidate instruments are selected through NASA Research Announcement (NRA) process [l]. For example, MIDP 161998-2000) selected and developed 10 instruments, MIDP II (2003-2005) 16 instruments, and MIDP III (2004-2006) II instruments.Working with PIs, JPL has been managing the MIDP tasks since September 1998. All the instruments being developed under MIDP have been selected through a highly competitive NRA process, and employ state-of-the-art technology. So far, four MIDP funded instruments have been selected by two Mars missions (these instruments have further been discussed in this paper).

  2. An integrated assessment instrument: Developing and validating instrument for facilitating critical thinking abilities and science process skills on electrolyte and nonelectrolyte solution matter

    NASA Astrophysics Data System (ADS)

    Astuti, Sri Rejeki Dwi; Suyanta, LFX, Endang Widjajanti; Rohaeti, Eli

    2017-05-01

    The demanding of assessment in learning process was impact by policy changes. Nowadays, assessment is not only emphasizing knowledge, but also skills and attitudes. However, in reality there are many obstacles in measuring them. This paper aimed to describe how to develop integrated assessment instrument and to verify instruments' validity such as content validity and construct validity. This instrument development used test development model by McIntire. Development process data was acquired based on development test step. Initial product was observed by three peer reviewer and six expert judgments (two subject matter experts, two evaluation experts and two chemistry teachers) to acquire content validity. This research involved 376 first grade students of two Senior High Schools in Bantul Regency to acquire construct validity. Content validity was analyzed used Aiken's formula. The verifying of construct validity was analyzed by exploratory factor analysis using SPSS ver 16.0. The result show that all constructs in integrated assessment instrument are asserted valid according to content validity and construct validity. Therefore, the integrated assessment instrument is suitable for measuring critical thinking abilities and science process skills of senior high school students on electrolyte solution matter.

  3. NASA SMD Airborne Science Capabilities for Development and Testing of New Instruments

    NASA Technical Reports Server (NTRS)

    Fladeland, Matthew

    2015-01-01

    The SMD NASA Airborne Science Program operates and maintains a fleet of highly modified aircraft to support instrument development, satellite instrument calibration, data product validation and earth science process studies. This poster will provide an overview of aircraft available to NASA researchers including performance specifications and modifications for instrument support, processes for requesting aircraft time and developing cost estimates for proposals, and policies and procedures required to ensure safety of flight.

  4. From theory to 'measurement' in complex interventions: methodological lessons from the development of an e-health normalisation instrument.

    PubMed

    Finch, Tracy L; Mair, Frances S; O'Donnell, Catherine; Murray, Elizabeth; May, Carl R

    2012-05-17

    Although empirical and theoretical understanding of processes of implementation in health care is advancing, translation of theory into structured measures that capture the complex interplay between interventions, individuals and context remain limited. This paper aimed to (1) describe the process and outcome of a project to develop a theory-based instrument for measuring implementation processes relating to e-health interventions; and (2) identify key issues and methodological challenges for advancing work in this field. A 30-item instrument (Technology Adoption Readiness Scale (TARS)) for measuring normalisation processes in the context of e-health service interventions was developed on the basis on Normalization Process Theory (NPT). NPT focuses on how new practices become routinely embedded within social contexts. The instrument was pre-tested in two health care settings in which e-health (electronic facilitation of healthcare decision-making and practice) was used by health care professionals. The developed instrument was pre-tested in two professional samples (N=46; N=231). Ratings of items representing normalisation 'processes' were significantly related to staff members' perceptions of whether or not e-health had become 'routine'. Key methodological challenges are discussed in relation to: translating multi-component theoretical constructs into simple questions; developing and choosing appropriate outcome measures; conducting multiple-stakeholder assessments; instrument and question framing; and more general issues for instrument development in practice contexts. To develop theory-derived measures of implementation process for progressing research in this field, four key recommendations are made relating to (1) greater attention to underlying theoretical assumptions and extent of translation work required; (2) the need for appropriate but flexible approaches to outcomes measurement; (3) representation of multiple perspectives and collaborative nature of work; and (4) emphasis on generic measurement approaches that can be flexibly tailored to particular contexts of study.

  5. Survey Instrument Validity Part I: Principles of Survey Instrument Development and Validation in Athletic Training Education Research

    ERIC Educational Resources Information Center

    Burton, Laura J.; Mazerolle, Stephanie M.

    2011-01-01

    Context: Instrument validation is an important facet of survey research methods and athletic trainers must be aware of the important underlying principles. Objective: To discuss the process of survey development and validation, specifically the process of construct validation. Background: Athletic training researchers frequently employ the use of…

  6. Development of the Quality of Australian Nursing Documentation in Aged Care (QANDAC) instrument to assess paper-based and electronic resident records.

    PubMed

    Wang, Ning; Björvell, Catrin; Hailey, David; Yu, Ping

    2014-12-01

    To develop an Australian nursing documentation in aged care (Quality of Australian Nursing Documentation in Aged Care (QANDAC)) instrument to measure the quality of paper-based and electronic resident records. The instrument was based on the nursing process model and on three attributes of documentation quality identified in a systematic review. The development process involved five phases following approaches to designing criterion-referenced measures. The face and content validities and the inter-rater reliability of the instrument were estimated using a focus group approach and consensus model. The instrument contains 34 questions in three sections: completion of nursing history and assessment, description of care process and meeting the requirements of data entry. Estimates of the validity and inter-rater reliability of the instrument gave satisfactory results. The QANDAC instrument may be a useful audit tool for quality improvement and research in aged care documentation. © 2013 ACOTA.

  7. Development of an Instrument to Measure Medical Students' Attitudes toward People with Disabilities

    ERIC Educational Resources Information Center

    Symons, Andrew B.; Fish, Reva; McGuigan, Denise; Fox, Jeffery; Akl, Elie A.

    2012-01-01

    As curricula to improve medical students' attitudes toward people with disabilities are developed, instruments are needed to guide the process and evaluate effectiveness. The authors developed an instrument to measure medical students' attitudes toward people with disabilities. A pilot instrument with 30 items in four sections was administered to…

  8. The lightbulb project: New music for new percussion instruments

    NASA Astrophysics Data System (ADS)

    Baumbusch, Brian

    This thesis is about the process behind building, tuning, and composing music for a new set of metallophones called the "Lightbulb" instruments. This project began in 2011 and has continued to expand over the past two years: the first piece to be written for the instruments is titled Prana, and this thesis describes how the process of building and tuning the instruments informed the compositional process behind Prana. The premiere of Prana led to the formation of the Lightbulb Ensemble, which performs on these new instruments. The instruments and the group continue to develop.

  9. The development of an integrated assessment instrument for measuring analytical thinking and science process skills

    NASA Astrophysics Data System (ADS)

    Irwanto, Rohaeti, Eli; LFX, Endang Widjajanti; Suyanta

    2017-05-01

    This research aims to develop instrument and determine the characteristics of an integrated assessment instrument. This research uses 4-D model, which includes define, design, develop, and disseminate. The primary product is validated by expert judgment, tested it's readability by students, and assessed it's feasibility by chemistry teachers. This research involved 246 students of grade XI of four senior high schools in Yogyakarta, Indonesia. Data collection techniques include interview, questionnaire, and test. Data collection instruments include interview guideline, item validation sheet, users' response questionnaire, instrument readability questionnaire, and essay test. The results show that the integrated assessment instrument has Aiken validity value of 0.95. Item reliability was 0.99 and person reliability was 0.69. Teachers' response to the integrated assessment instrument is very good. Therefore, the integrated assessment instrument is feasible to be applied to measure the students' analytical thinking and science process skills.

  10. Laboratory for Atmospheres: Instrument Systems Report

    NASA Technical Reports Server (NTRS)

    2011-01-01

    Studies of the atmospheres of our solar system's planets including our own require a comprehensive set of observations, relying on instruments on spacecraft, aircraft, balloons, and on the surface. Laboratory personnel define requirements, conceive concepts, and develop instrument systems for spaceflight missions, and for balloon, aircraft, and ground-based observations. Laboratory scientists also participate in the design of data processing algorithms, calibration techniques, and data processing systems. The instrument sections of this report are organized by measurement technique: lidar, passive, in situ and microwave. A number of instruments in various stages of development or modification are also described. This report will be updated as instruments evolve.

  11. Applying the Mixed Methods Instrument Development and Construct Validation Process: the Transformative Experience Questionnaire

    ERIC Educational Resources Information Center

    Koskey, Kristin L. K.; Sondergeld, Toni A.; Stewart, Victoria C.; Pugh, Kevin J.

    2018-01-01

    Onwuegbuzie and colleagues proposed the Instrument Development and Construct Validation (IDCV) process as a mixed methods framework for creating and validating measures. Examples applying IDCV are lacking. We provide an illustrative case integrating the Rasch model and cognitive interviews applied to the development of the Transformative…

  12. Vocational Education Students' Generic Working Life Competencies: Developing a Self-Assessment Instrument

    ERIC Educational Resources Information Center

    Kyndt, Eva; Janssens, Ine; Coertjens, Liesje; Gijbels, David; Donche, Vincent; Van Petegem, Peter

    2014-01-01

    The current study reports on the process of developing a self-assessment instrument for vocational education students' generic working life competencies. The instrument was developed based on a competence framework and in close collaboration with several vocational education teachers and intermediary organisations offering various human…

  13. But Does It Work? Reflective Activities, Learning Outcomes and Instrumental Learning in Continuing Professional Development

    ERIC Educational Resources Information Center

    Roessger, Kevin M.

    2015-01-01

    This paper examines the relationship between reflective practice and instrumental learning within the context of continuing professional development (CPD). It is argued that instrumental learning is a unique process of adult learning, and reflective practice's impact on learning outcomes in instrumental learning contexts remains unclear. A…

  14. Development and Validation of an Instrument to Assess the Implementation of Family-Centred Care in Traditional Open Bay Neonatal Intensive Care Units

    ERIC Educational Resources Information Center

    Al-Motlaq, Mohammad A.; Abuidhail, Jamila; Salameh, Taghreed; Awwad, Wesam

    2017-01-01

    Objective: To develop an instrument to study family-centred care (FCC) in traditional open bay Neonatal Intensive Care Units (NICUs). Methods: The development process involved constructing instrument's items, establishing content validity by an expert panel and testing the instrument for validity and reliability with a convenience sample of 25…

  15. Methods of dental instrument processing, sterilization, and storage--a review.

    PubMed

    Thomas, Lisa P; Bebermeyer, Richard D; Dickinson, Sharon K

    2005-10-01

    A comprehensive instrument processing and sterilization program in the dental office is essential to ensure that the DHCP and the public are protected from disease transmission due to contaminated instruments/ devices. The Centers for Disease Control and Prevention and other organizations have made recommendations to help dental personnel with this aspect of patient care. By following the CDC's latest guidelines, the DHCP can develop an optimal program of dental instrument processing, sterilization and storage.

  16. Survey Instrument Validity Part II: Validation of a Survey Instrument Examining Athletic Trainers' Knowledge and Practice Beliefs Regarding Exertional Heat Stroke

    ERIC Educational Resources Information Center

    Burton, Laura J.; Mazerolle, Stephanie M.

    2011-01-01

    Objective: The purpose of this article is to discuss the process of developing and validating an instrument to investigate an athletic trainer's attitudes and behaviors regarding the recognition and treatment of exertional heat stroke. Background: Following up from our initial paper, which discussed the process of survey instrument design and…

  17. Design and Implementation Content Validity Study: Development of an instrument for measuring Patient-Centered Communication

    PubMed Central

    Zamanzadeh, Vahid; Ghahramanian, Akram; Rassouli, Maryam; Abbaszadeh, Abbas; Alavi-Majd, Hamid; Nikanfar, Ali-Reza

    2015-01-01

    Introduction: The importance of content validity in the instrument psychometric and its relevance with reliability, have made it an essential step in the instrument development. This article attempts to give an overview of the content validity process and to explain the complexity of this process by introducing an example. Methods: We carried out a methodological study conducted to examine the content validity of the patient-centered communication instrument through a two-step process (development and judgment). At the first step, domain determination, sampling (item generation) and instrument formation and at the second step, content validity ratio, content validity index and modified kappa statistic was performed. Suggestions of expert panel and item impact scores are used to examine the instrument face validity. Results: From a set of 188 items, content validity process identified seven dimensions includes trust building (eight items), informational support (seven items), emotional support (five items), problem solving (seven items), patient activation (10 items), intimacy/friendship (six items) and spirituality strengthening (14 items). Content validity study revealed that this instrument enjoys an appropriate level of content validity. The overall content validity index of the instrument using universal agreement approach was low; however, it can be advocated with respect to the high number of content experts that makes consensus difficult and high value of the S-CVI with the average approach, which was equal to 0.93. Conclusion: This article illustrates acceptable quantities indices for content validity a new instrument and outlines them during design and psychometrics of patient-centered communication measuring instrument. PMID:26161370

  18. A Boresight Adjustment Mechanism for use on Laser Altimeters

    NASA Technical Reports Server (NTRS)

    Hakun, Claef; Budinoff, Jason; Brown, Gary; Parong, Fil; Morell, Armando

    2004-01-01

    This paper describes the development of the Boresight Adjustment Mechanism (BAM) for the Geoscience Laser Altimeter System (GLAS) Instrument. The BAM was developed late in the integration and test phase of the GLAS instrument flight program. Thermal vacuum tests of the GLAS instrument indicated that the instrument boresight alignment stability over temperature may be marginal. To reduce the risk that GLAS may not be able to meet the boresight alignment requirements, an intensive effort was started to develop a BAM. Observatory-level testing and further evaluation of the boresight alignment data indicated that sufficient margin could be obtained utilizing existing instrument resources and therefore the BAM was never integrated onto the GLAS Instrument. However, the BAM was designed fabricated and fully qualified over a 4 month timeframe to be capable of precisely steering (< 1 arcsec over 300 arcsec) the output of three independent lasers to ensure the alignment between the transmit and receive paths of the GLAS instrument. The short timeline for the development of the mechanism resulted in several interesting design solutions. This paper discusses the requirement definition, design, and testing processes of the BAM development effort, how the design was affected by the extremely tight development schedule, and the lessons learned throughout the process.

  19. Distributed framework for dyanmic telescope and instrument control

    NASA Astrophysics Data System (ADS)

    Ames, Troy J.; Case, Lynne

    2003-02-01

    Traditionally, instrument command and control systems have been developed specifically for a single instrument. Such solutions are frequently expensive and are inflexible to support the next instrument development effort. NASA Goddard Space Flight Center is developing an extensible framework, known as Instrument Remote Control (IRC) that applies to any kind of instrument that can be controlled by a computer. IRC combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML). A key aspect of the architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). IML is an XML dialect used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, communication mechanisms, and data processing algorithms. The IRC framework provides the ability to communicate to components anywhere on a network using the JXTA protocol for dynamic discovery of distributed components. JXTA (see http://www.jxta.org) is a generalized protocol that allows any devices connected by a network to communicate in a peer-to-peer manner. IRC uses JXTA to advertise a devices IML and discover devices of interest on the network. Devices can join or leave the network and thus join or leave the instrument control environment of IRC. Currently, several astronomical instruments are working with the IRC development team to develop custom components for IRC to control their instruments. These instruments include: High resolution Airborne Wideband Camera (HAWC), a first light instrument for the Stratospheric Observatory for Infrared Astronomy (SOFIA); Submillimeter And Far Infrared Experiment (SAFIRE), a Principal Investigator instrument for SOFIA; and Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE), a prototype of the SAFIRE instrument, used at the Caltech Submillimeter Observatory (CSO). Most recently, we have been working with the Submillimetre High

  20. XML in an Adaptive Framework for Instrument Control

    NASA Technical Reports Server (NTRS)

    Ames, Troy J.

    2004-01-01

    NASA Goddard Space Flight Center is developing an extensible framework for instrument command and control, known as Instrument Remote Control (IRC), that combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML). A key aspect of the architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). IML is an XML dialect used to describe interfaces to control and monitor the instrument, command sets and command formats, data streams, communication mechanisms, and data processing algorithms.

  1. Opportunity integrated assessment facilitating critical thinking and science process skills measurement on acid base matter

    NASA Astrophysics Data System (ADS)

    Sari, Anggi Ristiyana Puspita; Suyanta, LFX, Endang Widjajanti; Rohaeti, Eli

    2017-05-01

    Recognizing the importance of the development of critical thinking and science process skills, the instrument should give attention to the characteristics of chemistry. Therefore, constructing an accurate instrument for measuring those skills is important. However, the integrated instrument assessment is limited in number. The purpose of this study is to validate an integrated assessment instrument for measuring students' critical thinking and science process skills on acid base matter. The development model of the test instrument adapted McIntire model. The sample consisted of 392 second grade high school students in the academic year of 2015/2016 in Yogyakarta. Exploratory Factor Analysis (EFA) was conducted to explore construct validity, whereas content validity was substantiated by Aiken's formula. The result shows that the KMO test is 0.714 which indicates sufficient items for each factor and the Bartlett test is significant (a significance value of less than 0.05). Furthermore, content validity coefficient which is based on 8 experts is obtained at 0.85. The findings support the integrated assessment instrument to measure critical thinking and science process skills on acid base matter.

  2. Development and initial evaluation of an instrument to assess physiotherapists' clinical reasoning focused on clients' behavior change.

    PubMed

    Elvén, Maria; Hochwälder, Jacek; Dean, Elizabeth; Söderlund, Anne

    2018-05-01

    A systematically developed and evaluated instrument is needed to support investigations of physiotherapists' clinical reasoning integrated with the process of clients' behavior change. This study's aim was to develop an instrument to assess physiotherapy students' and physiotherapists' clinical reasoning focused on clients' activity-related behavior and behavior change, and initiate its evaluation, including feasibility and content validity. The study was conducted in three phases: 1) determination of instrument structure and item generation, based on a model, guidelines for assessing clinical reasoning, and existing measures; 2) cognitive interviews with five physiotherapy students to evaluate item understanding and feasibility; and 3) a Delphi process with 18 experts to evaluate content relevance. Phase 1 resulted in an instrument with four domains: Physiotherapist; Input from client; Functional behavioral analysis; and Strategies for behavior change. The instrument consists of case scenarios followed by items in which key features are identified, prioritized, or interpreted. Phase 2 resulted in revisions of problems and approval of feasibility. Phase 3 demonstrated high level of consensus regarding the instrument's content relevance. This feasible and content-validated instrument shows potential for use in investigations of physiotherapy students' and physiotherapists' clinical reasoning, however continued development and testing are needed.

  3. Validation of Reverse-Engineered and Additive-Manufactured Microsurgical Instrument Prototype.

    PubMed

    Singh, Ramandeep; Suri, Ashish; Anand, Sneh; Baby, Britty

    2016-12-01

    With advancements in imaging techniques, neurosurgical procedures are becoming highly precise and minimally invasive, thus demanding development of new ergonomically aesthetic instruments. Conventionally, neurosurgical instruments are manufactured using subtractive manufacturing methods. Such a process is complex, time-consuming, and impractical for prototype development and validation of new designs. Therefore, an alternative design process has been used utilizing blue light scanning, computer-aided designing, and additive manufacturing direct metal laser sintering (DMLS) for microsurgical instrument prototype development. Deviations of DMLS-fabricated instrument were studied by superimposing scan data of fabricated instrument with the computer-aided designing model. Content and concurrent validity of the fabricated prototypes was done by a group of 15 neurosurgeons by performing sciatic nerve anastomosis in small laboratory animals. Comparative scoring was obtained for the control and study instrument. T test was applied to the individual parameters and P values for force (P < .0001) and surface roughness (P < .01) were found to be statistically significant. These 2 parameters were further analyzed using objective measures. Results depicts that additive manufacturing by DMLS provides an effective method for prototype development. However, direct application of these additive-manufactured instruments in the operating room requires further validation. © The Author(s) 2016.

  4. Interdisciplinary Approach to the Development of Accessible Computer-Administered Measurement Instruments.

    PubMed

    Magasi, Susan; Harniss, Mark; Heinemann, Allen W

    2018-01-01

    Principles of fairness in testing require that all test takers, including people with disabilities, have an equal opportunity to demonstrate their capacity on the construct being measured. Measurement design features and assessment protocols can pose barriers for people with disabilities. Fairness in testing is a fundamental validity issue at all phases in the design, administration, and interpretation of measurement instruments in clinical practice and research. There is limited guidance for instrument developers on how to develop and evaluate the accessibility and usability of measurement instruments. This article describes a 6-stage iterative process for developing accessible computer-administered measurement instruments grounded in the procedures implemented across several major measurement initiatives. A key component of this process is interdisciplinary teams of accessibility experts, content and measurement experts, information technology experts, and people with disabilities working together to ensure that measurement instruments are accessible and usable by a wide range of users. The development of accessible measurement instruments is not only an ethical requirement, it also ensures better science by minimizing measurement bias, missing data, and attrition due to mismatches between the target population and test administration platform and protocols. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. Computer aided statistical process control for on-line instrumentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meils, D.E.

    1995-01-01

    On-line chemical process instrumentation historically has been used for trending. Recent technological advances in on-line instrumentation have improved the accuracy and reliability of on-line instrumentation. However, little attention has been given to validating and verifying on-line instrumentation. This paper presents two practical approaches for validating instrument performance by comparison of on-line instrument response to either another portable instrument or another bench instrument. Because the comparison of two instruments` performance to each other requires somewhat complex statistical calculations, a computer code (Lab Stats Pack{reg_sign}) is used to simplify the calculations. Lab Stats Pack{reg_sign} also develops control charts that may be usedmore » for continuous verification of on-line instrument performance.« less

  6. The Cognitive Processes Associated with Occupational/Career Indecision: A Model for Gifted Adolescents

    ERIC Educational Resources Information Center

    Jung, Jae Yup

    2013-01-01

    This study developed and tested a new model of the cognitive processes associated with occupational/career indecision for gifted adolescents. A survey instrument with rigorous psychometric properties, developed from a number of existing instruments, was administered to a sample of 687 adolescents attending three academically selective high schools…

  7. Thirty Meter Telescope science instruments: a status report

    NASA Astrophysics Data System (ADS)

    Simard, Luc; Ellerbroek, Brent; Bhatia, Ravinder; Radovan, Matthew; Chisholm, Eric

    2016-08-01

    An overview of the current status of the science instruments for the Thirty Meter Telescope is presented. Three first-light instruments as well as a science calibration unit for AO-assisted instruments are under development. Developing instrument collaborations that can design and build these challenging instruments remains an area of intense activity. In addition to the instruments themselves, a preliminary design for a facility cryogenic cooling system based on gaseous helium turbine expanders has been completed. This system can deliver a total of 2.4 kilowatts of cooling power at 65K to the instruments with essentially no vibrations. Finally, the process for developing future instruments beyond first light has been extensively discussed and will get under way in early 2017.

  8. Development and validation of instrument for ergonomic evaluation of tablet arm chairs

    PubMed Central

    Tirloni, Adriana Seára; dos Reis, Diogo Cunha; Bornia, Antonio Cezar; de Andrade, Dalton Francisco; Borgatto, Adriano Ferreti; Moro, Antônio Renato Pereira

    2016-01-01

    The purpose of this study was to develop and validate an evaluation instrument for tablet arm chairs based on ergonomic requirements, focused on user perceptions and using Item Response Theory (IRT). This exploratory study involved 1,633 participants (university students and professors) in four steps: a pilot study (n=26), semantic validation (n=430), content validation (n=11) and construct validation (n=1,166). Samejima's graded response model was applied to validate the instrument. The results showed that all the steps (theoretical and practical) of the instrument's development and validation processes were successful and that the group of remaining items (n=45) had a high consistency (0.95). This instrument can be used in the furniture industry by engineers and product designers and in the purchasing process of tablet arm chairs for schools, universities and auditoriums. PMID:28337099

  9. Commercialization of Kennedy Space Center Instrumentation Developed to Improve Safety, Reliability, Cost Effectiveness of Space Shuttle Processing, Launch, and Landing

    NASA Technical Reports Server (NTRS)

    Helms, William R.; Starr, Stanley O.

    1997-01-01

    Priorities and achievements of the Kennedy Space Center (KSF) Instrumentation Laboratories in improving operational safety and decreasing processing costs associated with the Shuttle vehicle are addressed. Technologies that have been or are in the process of technology transfer are reviewed, and routes by which commercial concerns can obtain licenses to other KSF Instrumentation Laboratory technologies are discussed.

  10. On Convergence of Development Costs and Cost Models for Complex Spaceflight Instrument Electronics

    NASA Technical Reports Server (NTRS)

    Kizhner, Semion; Patel, Umeshkumar D.; Kasa, Robert L.; Hestnes, Phyllis; Brown, Tammy; Vootukuru, Madhavi

    2008-01-01

    Development costs of a few recent spaceflight instrument electrical and electronics subsystems have diverged from respective heritage cost model predictions. The cost models used are Grass Roots, Price-H and Parametric Model. These cost models originated in the military and industry around 1970 and were successfully adopted and patched by NASA on a mission-by-mission basis for years. However, the complexity of new instruments recently changed rapidly by orders of magnitude. This is most obvious in the complexity of representative spaceflight instrument electronics' data system. It is now required to perform intermediate processing of digitized data apart from conventional processing of science phenomenon signals from multiple detectors. This involves on-board instrument formatting of computational operands from row data for example, images), multi-million operations per second on large volumes of data in reconfigurable hardware (in addition to processing on a general purpose imbedded or standalone instrument flight computer), as well as making decisions for on-board system adaptation and resource reconfiguration. The instrument data system is now tasked to perform more functions, such as forming packets and instrument-level data compression of more than one data stream, which are traditionally performed by the spacecraft command and data handling system. It is furthermore required that the electronics box for new complex instruments is developed for one-digit watt power consumption, small size and that it is light-weight, and delivers super-computing capabilities. The conflict between the actual development cost of newer complex instruments and its electronics components' heritage cost model predictions seems to be irreconcilable. This conflict and an approach to its resolution are addressed in this paper by determining the complexity parameters, complexity index, and their use in enhanced cost model.

  11. Integrated Payload Data Handling Systems Using Software Partitioning

    NASA Astrophysics Data System (ADS)

    Taylor, Alun; Hann, Mark; Wishart, Alex

    2015-09-01

    An integrated Payload Data Handling System (I-PDHS) is one in which multiple instruments share a central payload processor for their on-board data processing tasks. This offers a number of advantages over the conventional decentralised architecture. Savings in payload mass and power can be realised because the total processing resource is matched to the requirements, as opposed to the decentralised architecture here the processing resource is in effect the sum of all the applications. Overall development cost can be reduced using a common processor. At individual instrument level the potential benefits include a standardised application development environment, and the opportunity to run the instrument data handling application on a fully redundant and more powerful processing platform [1]. This paper describes a joint program by SCISYS UK Limited, Airbus Defence and Space, Imperial College London and RAL Space to implement a realistic demonstration of an I-PDHS using engineering models of flight instruments (a magnetometer and camera) and a laboratory demonstrator of a central payload processor which is functionally representative of a flight design. The objective is to raise the Technology Readiness Level of the centralised data processing technique by address the key areas of task partitioning to prevent fault propagation and the use of a common development process for the instrument applications. The project is supported by a UK Space Agency grant awarded under the National Space Technology Program SpaceCITI scheme. [1].

  12. Instruments to assess the perception of physicians in the decision-making process of specific clinical encounters: a systematic review

    PubMed Central

    Légaré, France; Moher, David; Elwyn, Glyn; LeBlanc, Annie; Gravel, Karine

    2007-01-01

    Background The measurement of processes and outcomes that reflect the complexity of the decision-making process within specific clinical encounters is an important area of research to pursue. A systematic review was conducted to identify instruments that assess the perception physicians have of the decision-making process within specific clinical encounters. Methods For every year available up until April 2007, PubMed, PsycINFO, Current Contents, Dissertation Abstracts and Sociological Abstracts were searched for original studies in English or French. Reference lists from retrieved studies were also consulted. Studies were included if they reported a self-administered instrument evaluating physicians' perceptions of the decision-making process within specific clinical encounters, contained sufficient description to permit critical appraisal and presented quantitative results based on administering the instrument. Two individuals independently assessed the eligibility of the instruments and abstracted information on their conceptual underpinnings, main evaluation domain, development, format, reliability, validity and responsiveness. They also assessed the quality of the studies that reported on the development of the instruments with a modified version of STARD. Results Out of 3431 records identified and screened for evaluation, 26 potentially relevant instruments were assessed; 11 met the inclusion criteria. Five instruments were published before 1995. Among those published after 1995, five offered a corresponding patient version. Overall, the main evaluation domains were: satisfaction with the clinical encounter (n = 2), mutual understanding between health professional and patient (n = 2), mental workload (n = 1), frustration with the clinical encounter (n = 1), nurse-physician collaboration (n = 1), perceptions of communication competence (n = 2), degree of comfort with a decision (n = 1) and information on medication (n = 1). For most instruments (n = 10), some reliability and validity criteria were reported in French or English. Overall, the mean number of items on the modified version of STARD was 12.4 (range: 2 to 18). Conclusion This systematic review provides a critical appraisal and repository of instruments that assess the perception physicians have of the decision-making process within specific clinical encounters. More research is needed to pursue the validation of the existing instruments and the development of patient versions. This will help researchers capture the complexity of the decision-making process within specific clinical encounters. PMID:17937801

  13. The Development of a Student Survey on Attitudes towards Mathematics Teaching-Learning Processes

    ERIC Educational Resources Information Center

    Mutohir, Toho Cholik; Lowrie, Tom; Patahuddin, Sitti Maesuri

    2018-01-01

    This study aimed to develop a survey instrument to measure student attitudes towards mathematics teaching-learning processes that is appropriate for the Indonesian context. This study consisted of two phases: Phase 1 (n = 320) was a pilot study to assess the suitability of the instrument items for Indonesian students. Phase 2 (n = 1001) was…

  14. Process Skill Assessment Instrument: Innovation to measure student’s learning result holistically

    NASA Astrophysics Data System (ADS)

    Azizah, K. N.; Ibrahim, M.; Widodo, W.

    2018-01-01

    Science process skills (SPS) are very important skills for students. However, the fact that SPS is not being main concern in the primary school learning is undeniable. This research aimed to develop a valid, practical, and effective assessment instrument to measure student’s SPS. Assessment instruments comprise of worksheet and test. This development research used one group pre-test post-test design. Data were obtained with validation, observation, and test method to investigate validity, practicality, and the effectivenss of the instruments. Results showed that the validity of assessment instruments is very valid, the reliability is categorized as reliable, student SPS activities have a high percentage, and there is significant improvement on student’s SPS score. It can be concluded that assessment instruments of SPS are valid, practical, and effective to be used to measure student’s SPS result.

  15. Distributed Framework for Dynamic Telescope and Instrument Control

    NASA Astrophysics Data System (ADS)

    Ames, Troy J.; Case, Lynne

    2002-12-01

    Traditionally, instrument command and control systems have been developed specifically for a single instrument. Such solutions are frequently expensive and are inflexible to support the next instrument development effort. NASA Goddard Space Flight Center is developing an extensible framework, known as Instrument Remote Control (IRC) that applies to any kind of instrument that can be controlled by a computer. IRC combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML). A key aspect of the architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). IML is an XML dialect used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, communication mechanisms, and data processing algorithms. The IRC framework provides the ability to communicate to components anywhere on a network using the JXTA protocol for dynamic discovery of distributed components. JXTA (see http://www.jxta.org) is a generalized protocol that allows any devices connected by a network to communicate in a peer-to-peer manner. IRC uses JXTA to advertise a device?s IML and discover devices of interest on the network. Devices can join or leave the network and thus join or leave the instrument control environment of IRC. Currently, several astronomical instruments are working with the IRC development team to develop custom components for IRC to control their instruments. These instruments include: High resolution Airborne Wideband Camera (HAWC), a first light instrument for the Stratospheric Observatory for Infrared Astronomy (SOFIA); Submillimeter And Far Infrared Experiment (SAFIRE), a principal investigator instrument for SOFIA; and Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE), a prototype of the SAFIRE instrument, used at the Caltech Submillimeter Observatory (CSO). Most recently, we have been working with the Submillimetre High Angular Resolution Camera IInd Generation (SHARCII) at the CSO to investigate using IRC capabilities with the SHARC instrument.

  16. Distributed Framework for Dynamic Telescope and Instrument Control

    NASA Technical Reports Server (NTRS)

    Ames, Troy J.; Case, Lynne

    2002-01-01

    Traditionally, instrument command and control systems have been developed specifically for a single instrument. Such solutions are frequently expensive and are inflexible to support the next instrument development effort. NASA Goddard Space Flight Center is developing an extensible framework, known as Instrument Remote Control (IRC) that applies to any kind of instrument that can be controlled by a computer. IRC combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML). A key aspect of the architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). IML is an XML dialect used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, communication mechanisms, and data processing algorithms. The IRC framework provides the ability to communicate to components anywhere on a network using the JXTA protocol for dynamic discovery of distributed components. JXTA (see httD://www.jxta.org,) is a generalized protocol that allows any devices connected by a network to communicate in a peer-to-peer manner. IRC uses JXTA to advertise a device's IML and discover devices of interest on the network. Devices can join or leave the network and thus join or leave the instrument control environment of IRC. Currently, several astronomical instruments are working with the IRC development team to develop custom components for IRC to control their instruments. These instruments include: High resolution Airborne Wideband Camera (HAWC), a first light instrument for the Stratospheric Observatory for Infrared Astronomy (SOFIA); Submillimeter And Far Infrared Experiment (SAFIRE), a Principal Investigator instrument for SOFIA; and Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE), a prototype of the SAFIRE instrument, used at the Caltech Submillimeter Observatory (CSO). Most recently, we have been working with the Submillimetre High Angular Resolution Camera IInd Generation (SHARCII) at the CSO to investigate using IRC capabilities with the SHARC instrument.

  17. The Case for Musical Instrument Training in Cerebral Palsy for Neurorehabilitation

    PubMed Central

    2016-01-01

    Recent imaging studies in cerebral palsy (CP) have described several brain structural changes, functional alterations, and neuroplastic processes that take place after brain injury during early development. These changes affect motor pathways as well as sensorimotor networks. Several of these changes correlate with behavioral measures of motor and sensory disability. It is now widely acknowledged that management of sensory deficits is relevant for rehabilitation in CP. Playing a musical instrument demands the coordination of hand movements with integrated auditory, visual, and tactile feedback, in a process that recruits multiple brain regions. These multiple demands during instrument playing, together with the entertaining character of music, have led to the development and investigation of music-supported therapies, especially for rehabilitation with motor disorders resulting from brain damage. We review scientific evidence that supports the use of musical instrument playing for rehabilitation in CP. We propose that active musical instrument playing may be an efficient means for triggering neuroplastic processes necessary for the development of sensorimotor skills in patients with early brain damage. We encourage experimental research on neuroplasticity and on its impact on the physical and personal development of individuals with CP. PMID:27867664

  18. The Case for Musical Instrument Training in Cerebral Palsy for Neurorehabilitation.

    PubMed

    Alves-Pinto, Ana; Turova, Varvara; Blumenstein, Tobias; Lampe, Renée

    2016-01-01

    Recent imaging studies in cerebral palsy (CP) have described several brain structural changes, functional alterations, and neuroplastic processes that take place after brain injury during early development. These changes affect motor pathways as well as sensorimotor networks. Several of these changes correlate with behavioral measures of motor and sensory disability. It is now widely acknowledged that management of sensory deficits is relevant for rehabilitation in CP. Playing a musical instrument demands the coordination of hand movements with integrated auditory, visual, and tactile feedback, in a process that recruits multiple brain regions. These multiple demands during instrument playing, together with the entertaining character of music, have led to the development and investigation of music-supported therapies, especially for rehabilitation with motor disorders resulting from brain damage. We review scientific evidence that supports the use of musical instrument playing for rehabilitation in CP. We propose that active musical instrument playing may be an efficient means for triggering neuroplastic processes necessary for the development of sensorimotor skills in patients with early brain damage. We encourage experimental research on neuroplasticity and on its impact on the physical and personal development of individuals with CP.

  19. Development and Validation of a Two-Tier Instrument to Examine Understanding of Internal Transport in Plants and the Human Circulatory System

    ERIC Educational Resources Information Center

    Wang, Jing-Ru

    2004-01-01

    This study is intended to develop an assessment instrument to investigate students' understandings about internal transport in plants and human circulatory system. A refined process of a two-tier diagnostic test was used to develop the instrument. Finally, three versions of the Internal Transport in Plants and the Human Circulatory System test…

  20. Control of vacuum induction brazing system for sealing of instrumentation feed-through

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sung Ho Ahn; Jintae Hong; Chang Young Joung

    2015-07-01

    The integrity of instrumentation cables is an important performance parameter in addition to the sealing performance in the brazing process. An accurate brazing control was developed for the brazing of the instrumentation feed-through in the vacuum induction brazing system in this paper. The experimental results show that the accurate brazing temperature control performance is achieved by the developed control scheme. Consequently, the sealing performances of the instrumentation feed-through and the integrities of the instrumentation cables were satisfied after brazing. (authors)

  1. Control of Vacuum Induction Brazing System for Sealing of Instrumentation Feedthrough

    NASA Astrophysics Data System (ADS)

    Ahn, Sung Ho; Hong, Jintae; Joung, Chang Young; Heo, Sung Ho

    2017-04-01

    The integrity of instrumentation cables is an important performance parameter in the brazing process, along with the sealing performance. In this paper, an accurate control scheme for brazing of the instrumentation feedthrough in a vacuum induction brazing system was developed. The experimental results show that the accurate brazing temperature control performance is achieved by the developed control scheme. It is demonstrated that the sealing performances of the instrumentation feedthrough and the integrity of the instrumentation cables are to be acceptable after brazing.

  2. Mechanistic design data from ODOT instrumented pavement sites : phase II report.

    DOT National Transportation Integrated Search

    2017-03-01

    This investigation examined data obtained from three previously-instrumented pavement test sites in Oregon. Data processing algorithms and templates were developed for each test site that facilitated full processing of all the data to build databases...

  3. Mechanistic design data from ODOT instrumented pavement sites : phase 1 report.

    DOT National Transportation Integrated Search

    2017-03-01

    This investigation examined data obtained from three previously-instrumented pavement test sites in Oregon. Data processing algorithms and templates were developed for each test site that facilitated full processing of all the data to build databases...

  4. Development of an Instrument for the Measurement of Leadership Commitment to Organizational Process

    ERIC Educational Resources Information Center

    Hylton, Peter D.

    2013-01-01

    The purpose of this research study was to create a new instrument designed to examine the commitment of an organization's leadership to following organizational processes, as measured by stakeholder perceptions. This instrument was designed to aid in closure of a gap in the field of leadership studies relative to the impact that a leader's…

  5. Considerations of How to Study Learning Processes when Students Use GIS as an Instrument for Developing Spatial Thinking Skills

    ERIC Educational Resources Information Center

    Madsen, Lene Moller; Rump, Camilla

    2012-01-01

    Within the last 30 years, geographical information systems (GIS) have been used increasingly in the training of geographers. On the basis of the philosophy of technology and instrumental genesis, we sketch how the use of instruments interacts with learning processes and outline how this can be studied. We empirically analyse students' learning…

  6. Instrument Packages for the Cold, Dark, High Radiation Environments

    NASA Technical Reports Server (NTRS)

    Clark, P. E.; Millar, P. S.; Yeh, P. S.; Beamna, B.; Brigham, D.; Feng, S.

    2011-01-01

    We are developing a small cold temperature instrument package concept that integrates a cold temperature power system and radhard ultra low temperature ultra low power electronics components and power supplies now under development into a cold temperature surface operational version of a planetary surface instrument package. We are already in the process of developing a lower power lower tem-perature version for an instrument of mutual interest to SMD and ESMD to support the search for volatiles (the mass spectrometer VAPoR, Volatile Analysis by Pyrolysis of Regolith) both as a stand alone instrument and as part of an environmental monitoring package.

  7. Qualitative adaptation of child behaviour problem instruments in a developing-country setting.

    PubMed

    Khan, B; Avan, B I

    2014-07-08

    A key barrier to epidemiological research on child behaviour problems in developing countries is the lack of culturally relevant, internationally recognized psychometric instruments. This paper proposes a model for the qualitative adaptation of psychometric instruments in developing-country settings and presents a case study of the adaptation of 3 internationally recognized instruments in Pakistan: the Child Behavior Checklist, the Youth Self-Report and the Teacher's Report Form. This model encompassed a systematic procedure with 6 distinct phases to minimize bias and ensure equivalence with the original instruments: selection, deliberation, alteration, feasibility, testing and formal approval. The process was conducted in collaboration with the instruments' developer. A multidisciplinary working group of experts identified equivalence issues and suggested modifications. Focus group discussions with informants highlighted comprehension issues. Subsequently modified instruments were thoroughly tested. Finally, the instruments' developer approval further validated the qualitative adaptation. The study proposes a rigorous and systematic model to effectively achieve cultural adaptation of psychometric instruments.

  8. Developing Policy Instruments for Education in the EU: The European Qualifications Framework for Lifelong Learning

    ERIC Educational Resources Information Center

    Elken, Mari

    2015-01-01

    The European Qualifications Framework (EQF) for lifelong learning has been characterized as a policy instrument with a number of contested ideas, raising questions about the process through which such instruments are developed at European level. The introduction of the EQF is in this article examined through variations of neo-institutional theory:…

  9. System Definition of the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM)

    NASA Technical Reports Server (NTRS)

    Lundquist, Ray; Aymergen, Cagatay; VanCampen, Julie; Abell, James; Smith, Miles; Driggers, Phillip

    2008-01-01

    The Integrated Science Instrument Module (ISIM) for the James Webb Space Telescope (JWST) provides the critical functions and the environment for the four science instruments on JWST. This complex system development across many international organizations presents unique challenges and unique solutions. Here we describe how the requirement flow has been coordinated through the documentation system, how the tools and processes are used to minimize impact to the development of the affected interfaces, how the system design has matured, how the design review process operates, and how the system implementation is managed through reporting to ensure a truly world class scientific instrument compliment is created as the final product.

  10. Advanced CO2 removal process control and monitor instrumentation development

    NASA Technical Reports Server (NTRS)

    Heppner, D. B.; Dalhausen, M. J.; Klimes, R.

    1982-01-01

    A progam to evaluate, design and demonstrate major advances in control and monitor instrumentation was undertaken. A carbon dioxide removal process, one whose maturity level makes it a prime candidate for early flight demonstration was investigated. The instrumentation design incorporates features which are compatible with anticipated flight requirements. Current electronics technology and projected advances are included. In addition, the program established commonality of components for all advanced life support subsystems. It was concluded from the studies and design activities conducted under this program that the next generation of instrumentation will be greatly smaller than the prior one. Not only physical size but weight, power and heat rejection requirements were reduced in the range of 80 to 85% from the former level of research and development instrumentation. Using a microprocessor based computer, a standard computer bus structure and nonvolatile memory, improved fabrication techniques and aerospace packaging this instrumentation will greatly enhance overall reliability and total system availability.

  11. The development of a high-capacity instrument module heat transport system, appendixes

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Data sheets provide temperature requirements for 82 individual instruments that are under development or planned for grouping on a space platform or pallet. The scientific objectives of these instrument packages are related to solar physics, space plasma physics, astronomy, high energy astrophysics, resources observations, environmental observations, materials processing, and life sciences. System specifications are given for a high capacity instrument module heat transport system to be used with future payloads.

  12. The making of an instrument: from concept to market.

    PubMed

    Christoudias, G C

    1998-01-01

    This is an account of the steps one goes through in the development of a new device or instrument. It starts with the conditions that generate the need and then the concept of a new instrument and goes through the process of designing it and protecting it with a patent; it then proceeds through the development of a working prototype and a final refined product. It provides an outline of the steps needed to get the device into the national or international market by selling or licensing it to a company willing to develop it. To be able to demonstrate this process of invention and give real life to the steps involved in the making of an instrument as mentioned above, I describe the circumstances that generated the idea and the development of the Christoudias Tissue Approximator Grasper. The patent is published as issued to demonstrate its different components.

  13. Design and validation of instruments to measure knowledge.

    PubMed

    Elliott, T E; Regal, R R; Elliott, B A; Renier, C M

    2001-01-01

    Measuring health care providers' learning after they have participated in educational interventions that use experimental designs requires valid, reliable, and practical instruments. A literature review was conducted. In addition, experience gained from designing and validating instruments for measuring the effect of an educational intervention informed this process. The eight main steps for designing, validating, and testing the reliability of instruments for measuring learning outcomes are presented. The key considerations and rationale for this process are discussed. Methods for critiquing and adapting existent instruments and creating new ones are offered. This study may help other investigators in developing valid, reliable, and practical instruments for measuring the outcomes of educational activities.

  14. [Development of Nanotechnology for X-Ray Astronomy Instrumentation

    NASA Technical Reports Server (NTRS)

    Schattenburg, Mark L.

    2004-01-01

    This Research Grant provides support for development of nanotechnology for x-ray astronomy instrumentation. MIT has made significant progress in several development areas. In the last year we have made considerable progress in demonstrating the high-fidelity patterning and replication of x-ray reflection gratings. We developed a process for fabricating blazed gratings in silicon with extremely smooth and sharp sawtooth profiles, and developed a nanoimprint process for replication. We also developed sophisticated new fixturing for holding thin optics during metrology without causing distortion. We developed a new image processing algorithm for our Shack-Hartmann tool that uses Zernike polynomials. This has resulted in much more accurate and repeatable measurements on thin optics.

  15. ACRF Instrumentation Status: New, Current, and Future - October – November 2007

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    JW Voyles

    2007-11-30

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) SBIR instrument development.

  16. A Combined Fabrication and Instrumentation Platform for Sample Preparation.

    PubMed

    Guckenberger, David J; Thomas, Peter C; Rothbauer, Jacob; LaVanway, Alex J; Anderson, Meghan; Gilson, Dan; Fawcett, Kevin; Berto, Tristan; Barrett, Kevin; Beebe, David J; Berry, Scott M

    2014-06-01

    While potentially powerful, access to molecular diagnostics is substantially limited in the developing world. Here we present an approach to reduced cost molecular diagnostic instrumentation that has the potential to empower developing world communities by reducing costs through streamlining the sample preparation process. In addition, this instrument is capable of producing its own consumable devices on demand, reducing reliance on assay suppliers. Furthermore, this instrument is designed with an "open" architecture, allowing users to visually observe the assay process and make modifications as necessary (as opposed to traditional "black box" systems). This open environment enables integration of microfluidic fabrication and viral RNA purification onto an easy-to-use modular system via the use of interchangeable trays. Here we employ this system to develop a protocol to fabricate microfluidic devices and then use these devices to isolate viral RNA from serum for the measurement of human immunodeficiency virus (HIV) viral load. Results obtained from this method show significantly reduced error compared with similar nonautomated sample preparation processes. © 2014 Society for Laboratory Automation and Screening.

  17. Measuring team factors thought to influence the success of quality improvement in primary care: a systematic review of instruments

    PubMed Central

    2013-01-01

    Background Measuring team factors in evaluations of Continuous Quality Improvement (CQI) may provide important information for enhancing CQI processes and outcomes; however, the large number of potentially relevant factors and associated measurement instruments makes inclusion of such measures challenging. This review aims to provide guidance on the selection of instruments for measuring team-level factors by systematically collating, categorizing, and reviewing quantitative self-report instruments. Methods Data sources: We searched MEDLINE, PsycINFO, and Health and Psychosocial Instruments; reference lists of systematic reviews; and citations and references of the main report of instruments. Study selection: To determine the scope of the review, we developed and used a conceptual framework designed to capture factors relevant to evaluating CQI in primary care (the InQuIRe framework). We included papers reporting development or use of an instrument measuring factors relevant to teamwork. Data extracted included instrument purpose; theoretical basis, constructs measured and definitions; development methods and assessment of measurement properties. Analysis and synthesis: We used qualitative analysis of instrument content and our initial framework to develop a taxonomy for summarizing and comparing instruments. Instrument content was categorized using the taxonomy, illustrating coverage of the InQuIRe framework. Methods of development and evidence of measurement properties were reviewed for instruments with potential for use in primary care. Results We identified 192 potentially relevant instruments, 170 of which were analyzed to develop the taxonomy. Eighty-one instruments measured constructs relevant to CQI teams in primary care, with content covering teamwork context (45 instruments measured enabling conditions or attitudes to teamwork), team process (57 instruments measured teamwork behaviors), and team outcomes (59 instruments measured perceptions of the team or its effectiveness). Forty instruments were included for full review, many with a strong theoretical basis. Evidence supporting measurement properties was limited. Conclusions Existing instruments cover many of the factors hypothesized to contribute to QI success. With further testing, use of these instruments measuring team factors in evaluations could aid our understanding of the influence of teamwork on CQI outcomes. Greater consistency in the factors measured and choice of measurement instruments is required to enable synthesis of findings for informing policy and practice. PMID:23410500

  18. Patient-Reported Outcome Instruments for Surgical and Traumatic Scars: A Systematic Review of their Development, Content, and Psychometric Validation.

    PubMed

    Mundy, Lily R; Miller, H Catherine; Klassen, Anne F; Cano, Stefan J; Pusic, Andrea L

    2016-10-01

    Patient-reported outcomes (PROs) are of growing importance in research and clinical care and may be used as primary outcomes or as compliments to traditional surgical outcomes. In assessing the impact of surgical and traumatic scars, PROs are often the most meaningful. To assess outcomes from the patient perspective, rigorously developed and validated PRO instruments are essential. The authors conducted a systematic literature review to identify PRO instruments developed and/or validated for patients with surgical and/or non-burn traumatic scars. Identified instruments were assessed for content, development process, and validation under recommended guidelines for PRO instrument development. The systematic review identified 6534 articles. After review, we identified four PRO instruments meeting inclusion criteria: patient and observer scar assessment scale (POSAS), bock quality of life questionnaire for patients with keloid and hypertrophic scarring (Bock), patient scar assessment questionnaire (PSAQ), and patient-reported impact of scars measure (PRISM). Common concepts measured were symptoms and psychosocial well-being. Only PSAQ had a dedicated appearance domain. Qualitative data were used to inform content for the PSAQ and PRISM, and a modern psychometric approach (Rasch Measurement Theory) was used to develop PRISM and to test POSAS. Overall, PRISM demonstrated the most rigorous design and validation process, however, was limited by the lack of a dedicated appearance domain. PRO instruments to evaluate outcomes in scars exist but vary in terms of concepts measured and psychometric soundness. This review discusses the strengths and weaknesses of existing instruments, highlighting the need for future scar-focused PRO instrument development. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  19. Patient perspective workshop: moving towards OMERACT guidelines for choosing or developing instruments to measure patient-reported outcomes.

    PubMed

    Kirwan, John R; Fries, James F; Hewlett, Sarah E; Osborne, Richard H; Newman, Stanton; Ciciriello, Sabina; van de Laar, Mart A; Dures, Emma; Minnock, Patricia; Heiberg, Turid; Sanderson, Tessa C; Flurey, Caroline A; Leong, Amy L; Montie, Pamela; Richards, Pam

    2011-08-01

    The workshop Choosing or Developing Instruments held at the Outcome Measures in Rheumatology (OMERACT) 10 meeting was designed to help participants think about the underlying methods of instrument development. Conference pre-reading material and 3 brief introductory presentations elaborated the issues, and participants broke into discussion groups before reconvening to share insights, engage in a more general discussion of the issues, and vote on recommendations. Tradeoffs between using current imperfect measures and the long and complex process of developing new instruments were considered, together with the need for rigor in patient-reported outcome (PRO) instrument development. The main considerations for PRO instrument development were listed and a research agenda for action produced. As part of the agenda for action, it is recommended that researchers and patient partners work together to tackle these issues, and that OMERACT bring forward proposals for acceptable instrument development protocols that would meet an enhanced "Truth" statement in the OMERACT Filter.

  20. A far-infrared spatial/spectral Fourier interferometry laboratory-based testbed instrument

    NASA Astrophysics Data System (ADS)

    Spencer, Locke D.; Naylor, David A.; Scott, Jeremy P.; Weiler, Vince F.; MacCrimmon, Roderick K.; Sitwell, Geoffrey R. H.; Ade, Peter A. R.

    2016-07-01

    We describe the current status, including preliminary design, characterization efforts, and recent progress, in the development of a spatial/spectral double Fourier laboratory-based interferometer testbed instrument within the Astronomical Instrumentation Group (AIG) laboratories at the University of Lethbridge, Canada (UL). Supported by CRC, CFI, and NSERC grants, this instrument development will provide laboratory demonstration of spatial-spectral interferometry with a concentration of furthering progress in areas including the development of spatial/spectral interferometry observation, data processing, characterization, and analysis techniques in the Far-Infrared (FIR) region of the electromagnetic spectrum.

  1. A concept taxonomy and an instrument hierarchy: tools for establishing and evaluating the conceptual framework of a patient-reported outcome (PRO) instrument as applied to product labeling claims.

    PubMed

    Erickson, Pennifer; Willke, Richard; Burke, Laurie

    2009-01-01

    To facilitate development and evaluation of a PRO instrument conceptual framework, we propose two tools--a PRO concept taxonomy and a PRO instrument hierarchy. FDA's draft guidance on patient reported outcome (PRO) measures states that a clear description of the conceptual framework of an instrument is useful for evaluating its adequacy to support a treatment benefit claim for use in product labeling the draft guidance, however does not propose tools for establishing or evaluating a PRO instrument's conceptual framework. We draw from our review of PRO concepts and instruments that appear in prescription drug labeling approved in the United States from 1997 to 2007. We propose taxonomy terms that define relationships between PRO concepts, including "family,"compound concept," and "singular concept." Based on the range of complexity represented by the concepts, as defined by the taxonomy, we propose nine instrument orders for PRO measurement. The nine orders range from individual event counts to multi-item, multiscale instruments. This analysis of PRO concepts and instruments illustrates that the taxonomy and hierarchy are applicable to PRO concepts across a wide range of therapeutic areas and provide a basis for defining the instrument conceptual framework complexity. Although the utility of these tools in the drug development, review, and approval processes has not yet been demonstrated, these tools could be useful to improve communication and enhance efficiency in the instrument development and review process.

  2. The Wound CARE Instrument: the process for developing standards for wound management education and programming.

    PubMed

    Orsted, Heather L; Woodbury, M Gail; Stevenson, Kimberly

    2012-06-01

    This article describes the collaborative process undertaken by the Canadian Association for Enterostomal Therapy and the Canadian Association of Wound Care in an effort to improve the quality of wound prevention and management education and programming. The end result of this process is the Wound CARE Instrument which promotes an interprofessional, collaborative appraisal process to support the development, adoption or adaption of wound management educational events and programs. © 2011 The Authors. © 2011 Blackwell Publishing Ltd and Medicalhelplines.com Inc.

  3. 4D Model on Assessing Psychomotor Aspect in Continental Food Processing Practice

    NASA Astrophysics Data System (ADS)

    Nurafiati, P.; Ana, A.; Ratnasusanti, H.; Maulana, I.

    2018-02-01

    This research aims to develop and find out the response of observers for the assessment instrument of student’s psychomotor aspect on continental food processing practice. This research belongs to development research with 4P model that confined till the definition, design, and development stages. The data that gained during the research is analyzed descriptively. Research’s product is assessment instrument rubric form that consists of performance’s aspect which should be assessed and performance’s quality which stated in gradation score with 0-4 level and performance description that completed with picture illustration in every single score. Product was validate and responded based on material, construction, language, objectively, systematic, and practicability aspects. The result show that assessment instrument of student’s psychomotor aspect on continental food processing practice which developed gain very good response with percentage of 84,47%.

  4. The evolution and development of an instrument to measure essential professional nursing practices.

    PubMed

    Kramer, Marlene; Brewer, Barbara B; Halfer, Diana; Hnatiuk, Cynthia Nowicki; MacPhee, Maura; Schmalenberg, Claudia

    2014-11-01

    Nursing continues to evolve from a task-oriented occupation to a holistic professional practice. Increased professionalism requires accurate measurement of care processes and practice. Nursing studies often omit measurement of the relationship between structures in the work environment and processes of care or between processes of care and patient outcomes. Process measurement is integral to understanding and improving nursing practice. This article describes the development of an updated Essentials of Magnetism process measurement instrument for clinical nurses (CNs) practicing on inpatient units in hospitals. It has been renamed Essential Professional Nursing Practices: CN.

  5. Launching GUPPI: the Green Bank Ultimate Pulsar Processing Instrument

    NASA Astrophysics Data System (ADS)

    DuPlain, Ron; Ransom, Scott; Demorest, Paul; Brandt, Patrick; Ford, John; Shelton, Amy L.

    2008-08-01

    The National Radio Astronomy Observatory (NRAO) is launching the Green Bank Ultimate Pulsar Processing Instrument (GUPPI), a prototype flexible digital signal processor designed for pulsar observations with the Robert C. Byrd Green Bank Telescope (GBT). GUPPI uses field programmable gate array (FPGA) hardware and design tools developed by the Center for Astronomy Signal Processing and Electronics Research (CASPER) at the University of California, Berkeley. The NRAO has been concurrently developing GUPPI software and hardware using minimal software resources. The software handles instrument monitor and control, data acquisition, and hardware interfacing. GUPPI is currently an expert-only spectrometer, but supports future integration with the full GBT production system. The NRAO was able to take advantage of the unique flexibility of the CASPER FPGA hardware platform, develop hardware and software in parallel, and build a suite of software tools for monitoring, controlling, and acquiring data with a new instrument over a short timeline of just a few months. The NRAO interacts regularly with CASPER and its users, and GUPPI stands as an example of what reconfigurable computing and open-source development can do for radio astronomy. GUPPI is modular for portability, and the NRAO provides the results of development as an open-source resource.

  6. Instrumentation for studying binder burnout in an immobilized plutonium ceramic wasteform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitchell, M; Pugh, D; Herman, C

    The Plutonium Immobilization Program produces a ceramic wasteform that utilizes organic binders. Several techniques and instruments were developed to study binder burnout on full size ceramic samples in a production environment. This approach provides a method for developing process parameters on production scale to optimize throughput, product quality, offgas behavior, and plant emissions. These instruments allow for offgas analysis, large-scale TGA, product quality observation, and thermal modeling. Using these tools, results from lab-scale techniques such as laser dilametry studies and traditional TGA/DTA analysis can be integrated. Often, the sintering step of a ceramification process is the limiting process step thatmore » controls the production throughput. Therefore, optimization of sintering behavior is important for overall process success. Furthermore, the capabilities of this instrumentation allows better understanding of plant emissions of key gases: volatile organic compounds (VOCs), volatile inorganics including some halide compounds, NO{sub x}, SO{sub x}, carbon dioxide, and carbon monoxide.« less

  7. AN EIGHT WEEK SUMMER INSTITUTE TRAINING PROGRAM TO TRAIN INSTRUCTORS OF INSTRUMENTATION TECHNOLOGY.

    ERIC Educational Resources Information Center

    MCKEE, DELBERT A.

    A SUMMER INSTITUTE IN INSTRUMENTATION TECHNOLOGY WAS HELD TO PROVIDE TEACHERS WITH CURRENT KNOWLEDGE ON AUTOMATIC, PROCESS-CONTROL INSTRUMENTATION. A PREVIOUSLY DEVELOPED GUIDE FOR A 2-YEAR, POST-HIGH SCHOOL CURRICULUM PROVIDED THE BASIS FOR INSTRUCTION AND DISCUSSION DURING THE INSTITUTE. THREE COURSES IN MEASUREMENT AND INSTRUMENT SHOP…

  8. An innovative on-board processor for lightsats

    NASA Technical Reports Server (NTRS)

    Henshaw, R. M.; Ballard, B. W.; Hayes, J. R.; Lohr, D. A.

    1990-01-01

    The Applied Physics Laboratory (APL) has developed a flightworthy custom microprocessor that increases capability and reduces development costs of lightsat science instruments. This device, called the FRISC (FORTH Reduced Instruction Set Computer), directly executes the high-level language called FORTH, which is ideally suited to the multitasking control and data processing environment of a spaceborne instrument processor. The FRISC will be flown as the onboard processor in the Magnetic Field Experiment on the Freja satllite. APL has achieved a significant increase in onboard processing capability with no increase in cost when compared to the magnetometer instrument on Freja's predecessor, the Viking satellite.

  9. Engineering the Lidar In-space Technology Experiment

    NASA Technical Reports Server (NTRS)

    Couch, Richard H.; Moore, Chris L.

    1992-01-01

    The Lidar In-space Technology Experiment (LITE) is being developed by NASA for flight on the Space Shuttle in early 1994. A discussion of the NASA four-phase design process is followed by a short history of the experiment heritage. The instrument is then described at the subsystem level from an engineering point of view, with special emphasis on the laser and the receiver. Some aspects of designing for the space environment are discussed, as well as the importance of contamination control, and product assurance. Finally, the instrument integration and test process is described and the current status of the instrument development is given.

  10. The Pediatrics Milestones Assessment Pilot: Development of Workplace-Based Assessment Content, Instruments, and Processes.

    PubMed

    Hicks, Patricia J; Margolis, Melissa; Poynter, Sue E; Chaffinch, Christa; Tenney-Soeiro, Rebecca; Turner, Teri L; Waggoner-Fountain, Linda; Lockridge, Robin; Clyman, Stephen G; Schwartz, Alan

    2016-05-01

    To report on the development of content and user feedback regarding the assessment process and utility of the workplace-based assessment instruments of the Pediatrics Milestones Assessment Pilot (PMAP). One multisource feedback instrument and two structured clinical observation instruments were developed and refined by experts in pediatrics and assessment to provide evidence for nine competencies based on the Pediatrics Milestones (PMs) and chosen to inform residency program faculty decisions about learners' readiness to serve as pediatric interns in the inpatient setting. During the 2012-2013 PMAP study, 18 U.S. pediatric residency programs enrolled interns and subinterns. Faculty, residents, nurses, and other observers used the instruments to assess learner performance through direct observation during a one-month rotation. At the end of the rotation, data were aggregated for each learner, milestone levels were assigned using a milestone classification form, and feedback was provided to learners. Learners and site leads were surveyed and/or interviewed about their experience as participants. Across the sites, 2,338 instruments assessing 239 learners were completed by 630 unique observers. Regarding end-of-rotation feedback, 93% of learners (128/137) agreed the assessments and feedback "helped me understand how those with whom I work perceive my performance," and 85% (117/137) agreed they were "useful for constructing future goals or identifying a developmental path." Site leads identified several benefits and challenges to the assessment process. PM-based instruments used in workplace-based assessment provide a meaningful and acceptable approach to collecting evidence of learner competency development. Learners valued feedback provided by PM-based assessment.

  11. The Practices of Existential Psychotherapists: Development and Application of an Observational Grid

    ERIC Educational Resources Information Center

    Correia, Edgar A.; Sartóris, Vítor; Fernandes, Tiago; Cooper, Mick; Berdondini, Lucia; Sousa, Daniel; Pires, Branca Sá; da Fonseca, João

    2018-01-01

    Within the major therapeutic paradigms, observational instruments have been developed to assess orientation-specific interventions or processes. However, to date, no such instrument exists to assess existential practices. Recent research indicates the key practices of existential therapists, and forms an empirical basis on which to develop an…

  12. In-Flight Thermal Performance of the Lidar In-Space Technology Experiment

    NASA Technical Reports Server (NTRS)

    Roettker, William

    1995-01-01

    The Lidar In-Space Technology Experiment (LITE) was developed at NASA s Langley Research Center to explore the applications of lidar operated from an orbital platform. As a technology demonstration experiment, LITE was developed to gain experience designing and building future operational orbiting lidar systems. Since LITE was the first lidar system to be flown in space, an important objective was to validate instrument design principles in such areas as thermal control, laser performance, instrument alignment and control, and autonomous operations. Thermal and structural analysis models of the instrument were developed during the design process to predict the behavior of the instrument during its mission. In order to validate those mathematical models, extensive engineering data was recorded during all phases of LITE's mission. This inflight engineering data was compared with preflight predictions and, when required, adjustments to the thermal and structural models were made to more accurately match the instrument s actual behavior. The results of this process for the thermal analysis and design of LITE are presented in this paper.

  13. Automated processing of endoscopic surgical instruments.

    PubMed

    Roth, K; Sieber, J P; Schrimm, H; Heeg, P; Buess, G

    1994-10-01

    This paper deals with the requirements for automated processing of endoscopic surgical instruments. After a brief analysis of the current problems, solutions are discussed. Test-procedures have been developed to validate the automated processing, so that the cleaning results are guaranteed and reproducable. Also a device for testing and cleaning was designed together with Netzsch Newamatic and PCI, called TC-MIC, to automate processing and reduce manual work.

  14. Measuring parent food practices: a systematic review of existing measures and examination of instruments

    PubMed Central

    2013-01-01

    During the last decade, there has been a rapid increase in development of instruments to measure parent food practices. Because these instruments often measure different constructs, or define common constructs differently, an evaluation of these instruments is needed. A systematic review of the literature was conducted to identify existing measures of parent food practices and to assess the quality of their development. The initial search used terms capturing home environment, parenting behaviors, feeding practices and eating behaviors, and was performed in October of 2009 using PubMed/Medline, PsychInfo, Web of knowledge (ISI), and ERIC, and updated in July of 2012. A review of titles and abstracts was used to narrow results, after which full articles were retrieved and reviewed. Only articles describing development of measures of parenting food practices designed for families with children 2-12 years old were retained for the current review. For each article, two reviewers extracted data and appraised the quality of processes used for instrument development and evaluation. The initial search yielded 28,378 unique titles; review of titles and abstracts narrowed the pool to 1,352 articles; from which 57 unique instruments were identified. The review update yielded 1,772 new titles from which14 additional instruments were identified. The extraction and appraisal process found that 49% of instruments clearly identified and defined concepts to be measured, and 46% used theory to guide instrument development. Most instruments (80%) had some reliability testing, with internal consistency being the most common (79%). Test-retest or inter-rater reliability was reported for less than half the instruments. Some form of validity evidence was reported for 84% of instruments. Construct validity was most commonly presented (86%), usually with analysis of associations with child diet or weight/BMI. While many measures of food parenting practices have emerged, particularly in recent years, few have demonstrated solid development methods. Substantial variation in items across different scales/constructs makes comparison between instruments extremely difficult. Future efforts should be directed toward consensus development of food parenting practices constructs and measures. PMID:23688157

  15. Use of a multimission system for cost effective support of planetary science data processing

    NASA Technical Reports Server (NTRS)

    Green, William B.

    1994-01-01

    JPL's Multimission Operations Systems Office (MOSO) provides a multimission facility at JPL for processing science instrument data from NASA's planetary missions. This facility, the Multimission Image Processing System (MIPS), is developed and maintained by MOSO to meet requirements that span the NASA family of planetary missions. Although the word 'image' appears in the title, MIPS is used to process instrument data from a variety of science instruments. This paper describes the design of a new system architecture now being implemented within the MIPS to support future planetary mission activities at significantly reduced operations and maintenance cost.

  16. Development of a portable multispectral thermal infrared camera

    NASA Technical Reports Server (NTRS)

    Osterwisch, Frederick G.

    1991-01-01

    The purpose of this research and development effort was to design and build a prototype instrument designated the 'Thermal Infrared Multispectral Camera' (TIRC). The Phase 2 effort was a continuation of the Phase 1 feasibility study and preliminary design for such an instrument. The completed instrument designated AA465 has application in the field of geologic remote sensing and exploration. The AA465 Thermal Infrared Camera (TIRC) System is a field-portable multispectral thermal infrared camera operating over the 8.0 - 13.0 micron wavelength range. Its primary function is to acquire two-dimensional thermal infrared images of user-selected scenes. Thermal infrared energy emitted by the scene is collected, dispersed into ten 0.5 micron wide channels, and then measured and recorded by the AA465 System. This multispectral information is presented in real time on a color display to be used by the operator to identify spectral and spatial variations in the scenes emissivity and/or irradiance. This fundamental instrument capability has a wide variety of commercial and research applications. While ideally suited for two-man operation in the field, the AA465 System can be transported and operated effectively by a single user. Functionally, the instrument operates as if it were a single exposure camera. System measurement sensitivity requirements dictate relatively long (several minutes) instrument exposure times. As such, the instrument is not suited for recording time-variant information. The AA465 was fabricated, assembled, tested, and documented during this Phase 2 work period. The detailed design and fabrication of the instrument was performed during the period of June 1989 to July 1990. The software development effort and instrument integration/test extended from July 1990 to February 1991. Software development included an operator interface/menu structure, instrument internal control functions, DSP image processing code, and a display algorithm coding program. The instrument was delivered to NASA in March 1991. Potential commercial and research uses for this instrument are in its primary application as a field geologists exploration tool. Other applications have been suggested but not investigated in depth. These are measurements of process control in commercial materials processing and quality control functions which require information on surface heterogeneity.

  17. Vocopher: The Career Collaboratory

    ERIC Educational Resources Information Center

    Glavin, Kevin W.; Savickas, Mark L.

    2010-01-01

    Vocopher: The Career Collaboratory is an Internet-based website (http://www.vocopher.com) that contains free career instruments and educational materials intended for practitioners, researchers, and teachers of career development. The instruments include inventories and tests designed to measure the processes that shape career development and work…

  18. Recent Developments in Positron Emission Tomography (PET) Instrumentation

    DOE R&D Accomplishments Database

    Derenzo, S. E.; Budinger, T. F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors.

  19. The 2010 AOP Workshop Summary Report

    NASA Technical Reports Server (NTRS)

    Hooker, Stanford B.; Morrow, John H.; Brown, James W.; Firestone, Elaine R.

    2011-01-01

    The rationale behind the current workshop, which was hosted by Biospherical Instruments Inc. (BSI), was to update the community and get community input with respect to the following: topics not addressed during the first workshop, specifically the processing of above-water apparent optical property (AOP data) within the Processing of Radiometric Observations of Seawater using Information Technologies (PROSIT) architecture; PROSIT data processing issues that have developed or tasks that have been completed, since the first workshop; and NASA instrumentation developments, both above- and in-water, that are relevant to both workshops and next generation mission planning. The workshop emphasized presentations on new AOP instrumentation, desired and required features for processing above-water measurements of the AOPs of seawater, working group discussions, and a community update for the in-water data processing already present in PROSIT. The six working groups were organized as follows: a) data ingest and data products; b) required and desired features for optically shallow and optically deep waters; c) contamination rejection (clouds), corrections, and data filtering; d) sun photometry and polarimetry; e) instrumentation networks; and f) hyperspectral versus fixed-wavelength sensors. The instrumentation networks working group was intended to provide more detailed information about desired and required features of autonomous sampling systems. Plenary discussions produced a number of recommendations for evolving and documenting PROSIT.

  20. Validation of a Communication Process Measure for Coding Control in Counseling.

    ERIC Educational Resources Information Center

    Heatherington, Laurie

    The increasingly popular view of the counseling process from an interactional perspective necessitates the development of new measurement instruments which are suitable to the study of the reciprocal interaction between people. The validity of the Relational Communication Coding System, an instrument which operationalizes the constructs of…

  1. Motivation for Instrument Education: A Study from the Perspective of Expectancy-Value and Flow Theories

    ERIC Educational Resources Information Center

    Burak, Sabahat

    2014-01-01

    Problem Statement: In the process of instrument education, students being unwilling (lacking motivation) to play an instrument or to practise is a problem that educators frequently face. Recognizing the factors motivating the students will yield useful results for instrument educators in terms of developing correct teaching methods and approaches.…

  2. Developing an Assessment Instrument to Measure Early Elementary Teachers' Mathematical Knowledge for Teaching

    ERIC Educational Resources Information Center

    Schoen, Robert C.; Bray, Wendy; Wolfe, Christopher; Tazaz, Amanda M.; Nielsen, Lynne

    2017-01-01

    This study reports on the development and field study of K-TEEM, a web-based assessment instrument designed to measure mathematical knowledge for teaching (MKT) at the early elementary level. The development process involved alignment with early elementary curriculum standards, expert review of items and scoring criteria, cognitive interviews with…

  3. Development and validation of an international appraisal instrument for assessing the quality of clinical practice guidelines: the AGREE project.

    PubMed

    2003-02-01

    International interest in clinical practice guidelines has never been greater but many published guidelines do not meet the basic quality requirements. There have been renewed calls for validated criteria to assess the quality of guidelines. To develop and validate an international instrument for assessing the quality of the process and reporting of clinical practice guideline development. The instrument was developed through a multi-staged process of item generation, selection and scaling, field testing, and refinement procedures. 100 guidelines selected from 11 participating countries were evaluated independently by 194 appraisers with the instrument. Following refinement the instrument was further field tested on three guidelines per country by a new set of 70 appraisers. The final version of the instrument contained 23 items grouped into six quality domains with a 4 point Likert scale to score each item (scope and purpose, stakeholder involvement, rigour of development, clarity and presentation, applicability, editorial independence). 95% of appraisers found the instrument useful for assessing guidelines. Reliability was acceptable for most domains (Cronbach's alpha 0.64-0.88). Guidelines produced as part of an established guideline programme had significantly higher scores on editorial independence and, after the publication of a national policy, had significantly higher quality scores on rigour of development (p<0.005). Guidelines with technical documentation had higher scores on that domain (p<0.0001). This is the first time an appraisal instrument for clinical practice guidelines has been developed and tested internationally. The instrument is sensitive to differences in important aspects of guidelines and can be used consistently and easily by a wide range of professionals from different backgrounds. The adoption of common standards should improve the consistency and quality of the reporting of guideline development worldwide and provide a framework to encourage international comparison of clinical practice guidelines.

  4. Development and psychometric testing of an instrument to measure safety climate perceptions in community pharmacy.

    PubMed

    Newham, Rosemary; Bennie, Marion; Maxwell, David; Watson, Anne; de Wet, Carl; Bowie, Paul

    2014-12-01

    A positive and strong safety culture underpins effective learning from patient safety incidents in health care, including the community pharmacy (CP) setting. To build this culture, perceptions of safety climate must be measured with context-specific and reliable instruments. No pre-existing instruments were specifically designed or suitable for CP within Scotland. We therefore aimed to develop a psychometrically sound instrument to measure perceptions of safety climate within Scottish CPs. The first stage, development of a preliminary instrument, comprised three steps: (i) a literature review; (ii) focus group feedback; and (iii) content validation. The second stage, psychometric testing, consisted of three further steps: (iv) a pilot survey; (v) a survey of all CP staff within a single health board in NHS Scotland; and (vi) application of statistical methods, including principal components analysis and calculation of Cronbach's reliability coefficients, to derive the final instrument. The preliminary questionnaire was developed through a process of literature review and feedback. This questionnaire was completed by staff in 50 CPs from the 131 (38%) sampled. 250 completed questionnaires were suitable for analysis. Psychometric evaluation resulted in a 30-item instrument with five positively correlated safety climate factors: leadership, teamwork, safety systems, communication and working conditions. Reliability coefficients were satisfactory for the safety climate factors (α > 0.7) and overall (α = 0.93). The robust nature of the technical design and testing process has resulted in the development of an instrument with sufficient psychometric properties, which can be implemented in the community pharmacy setting in NHS Scotland. © 2014 John Wiley & Sons, Ltd.

  5. The development and validation of an instrument to measure preservice teachers' self-efficacy in regard to the teaching of science as inquiry

    NASA Astrophysics Data System (ADS)

    Dira-Smolleck, Lori

    The purpose of this study was to develop, validate and establish the reliability of an instrument that measures preservice teachers' self-efficacy in regard to the teaching of science as inquiry. The instrument (TSI) is based upon the work of Bandura, Riggs, and Enochs & Riggs (1990). The study used Bandura's theoretical framework in that the instrument uses the self-efficacy construct to explore the beliefs of prospective elementary science teachers with regards to the teaching of science through inquiry: specifically, the two dimensions of self-efficacy beliefs defined by Bandura: personal self-efficacy and outcome expectancy. Self-efficacy in regard to the teaching of science as inquiry was measured through the use of a 69-item Likert scale instrument designed by the author of the study. A 13-step plan was designed and followed in the process of developing the instrument. Using the results from Chronbach Alpha and Analysis of Variance, a 69-item instrument was found to achieve the greatest balance across the construct validity, reliability and item balance with the Essential Elements of Classroom Inquiry content matrix. Based on the standardized development processes used and the associated evidence, the TSI appears to be a content and construct valid instrument, with high internal reliability for use with prospective elementary teachers to assess self-efficacy beliefs in regard to the teaching of science as inquiry. Implications for research, policy and practice are also discussed.

  6. Development and validation of the Hogan Grief Reaction Checklist.

    PubMed

    Hogan, N S; Greenfield, D B; Schmidt, L A

    2001-01-01

    The purpose of this article is to provide data on a recently developed instrument to measure the multidimensional nature of the bereavement process. In contrast to widely used grief instruments that have been developed using rational methods of instrument construction, the Hogan Grief Reaction Checklist (HGRC) was developed empirically from data collected from bereaved adults who had experienced the death of a loved one. Factor analysis of the HGRC revealed 6 factors in the normal trajectory of the grieving process: Despair, Panic Behavior, Blame and Anger, Detachment, Disorganization, and Personal Growth. Additional data are provided that support reliability and validity of the HGRC as well as its ability to discriminate variability in the grieving process as a function of cause of death and time lapsed since death. Empirical support is also provided for Personal Growth as an integral component of the bereavement process. The article concludes by considering the substantive as well as psychometric findings of this research for such issues as traumatic grief, anticipatory grief, change in the bereaved person's self-schema, and spiritual and existential growth.

  7. Assessing oral health-related quality of life in children and adolescents: a systematic review and standardized comparison of available instruments.

    PubMed

    Zaror, Carlos; Pardo, Yolanda; Espinoza-Espinoza, Gerardo; Pont, Àngels; Muñoz-Millán, Patricia; Martínez-Zapata, María José; Vilagut, Gemma; Forero, Carlos G; Garin, Olatz; Alonso, Jordi; Ferrer, Montse

    2018-03-22

    To obtain a systematic and standardized evaluation of the current evidence on development process, metric properties, and administration issues of oral health-related quality of life instruments available for children and adolescents. A systematic search until October 2016 was conducted in PubMed, Embase, Lilacs, SciELO, and Cochrane databases. Articles with information regarding the development process, metric properties, and administration issues of pediatric instruments measuring oral health-related quality of life were eligible for inclusion. Two researchers independently evaluated each instrument applying the Evaluating Measures of Patient-Reported Outcomes (EMPRO) tool. An overall and seven attribute-specific EMPRO scores were calculated (range 0-100, worst to best): measurement model, reliability, validity, responsiveness, interpretability, burden, and alternative forms. We identified 18 instruments evaluated in 132 articles. From five instruments designed for preschoolers, the Early Childhood Oral Health Impact Scale (ECOHIS) obtained the highest overall EMPRO score (82.2). Of nine identified for schoolchildren and adolescents, the best rated instrument was the Child Perceptions Questionnaire 11-14 (82.1). Among the four instruments developed for any age, the Family Impact Scale (FIS) obtained the highest scores (80.3). The evidence supports the use of the ECOHIS for preschoolers, while the age is a key factor when choosing among the four recommended instruments for schoolchildren and adolescents. Instruments for specific conditions, symptoms, or treatments need further research on metric properties. Our results facilitate decision-making on the correct oral health-related quality of life instrument selection for any certain study purpose and population during the childhood and adolescence life cycle.

  8. Key issues in the thermal design of spaceborne cryogenic infrared instruments

    NASA Astrophysics Data System (ADS)

    Schember, Helene R.; Rapp, Donald

    1992-12-01

    Thermal design and analysis play an integral role in the development of spaceborne cryogenic infrared (IR) instruments. From conceptual sketches to final testing, both direct and derived thermal requirements place significant constraints on the instrument design. Although in practice these thermal requirements are interdependent, the sources of most thermal constraints may be grouped into six distinct categories. These are: (1) Detector temperatures, (2) Optics temperatures, (3) Pointing or alignment stability, (4) Mission lifetime, (5) Orbit, and (6) Test and Integration. In this paper, we discuss these six sources of thermal requirements with particular regard to development of instrument packages for low background infrared astronomical observatories. In the end, the thermal performance of these instruments must meet a set of thermal requirements. The development of these requirements is typically an ongoing and interactive process, however, and the thermal design must maintain flexibility and robustness throughout the process. The thermal (or cryogenic) engineer must understand the constraints imposed by the science requirements, the specific hardware, the observing environment, the mission design, and the testing program. By balancing these often competing factors, the system-oriented thermal engineer can work together with the experiment team to produce an effective overall design of the instrument.

  9. A Proposal for Evaluating Cognition in Assertiveness

    ERIC Educational Resources Information Center

    Vagos, Paula; Pereira, Anabela

    2010-01-01

    This article presents the development process and initial psychometric features of an instrument for evaluating cognition in assertiveness. This is an essential social skill for adolescent development and seems to encompass emotional, behavioral, and cognitive aspects. The instrument was created by combining both empirical and theoretical methods…

  10. Utilization of the High Flux Isotope Reactor at Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Selby, Douglas L; Bilheux, Hassina Z; Meilleur, Flora

    2015-01-01

    This paper addresses several aspects of the scientific utilization of the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR). Topics to be covered will include: 1) HFIR neutron scattering instruments and the formal instrument user program; 2) Recent upgrades to the neutron scattering instrument stations at the reactor, and 3) eMod a new tool for addressing instrument modifications and providing configuration control and design process for scientific instruments at HFIR and the Spallation Neutron Source (SNS). There are 15 operating neutron instrument stations at HFIR with 12 of them organized into a formal user program. Since the last presentationmore » on HFIR instruments at IGORR we have installed a Single Crystal Quasi-Laue Diffractometer instrument called IMAGINE; and we have made significant upgrades to HFIR neutron scattering instruments including the Cold Triple Axis Instrument, the Wide Angle Neutron Diffractometer, the Powder Diffractometer, and the Neutron Imaging station. In addition, we have initiated upgrades to the Thermal Triple Axis Instrument and the Bio-SANS cold neutron instrument detector system. All of these upgrades are tied to a continuous effort to maintain a high level neutron scattering user program at the HFIR. For the purpose of tracking modifications such as those mentioned and configuration control we have been developing an electronic system for entering instrument modification requests that follows a modification or instrument project through concept development, design, fabrication, installation, and commissioning. This system, which we call eMod, electronically leads the task leader through a series of questions and checklists that then identifies such things as ES&H and radiological issues and then automatically designates specific individuals for the activity review process. The system has been in use for less than a year and we are still working out some of the inefficiencies, but we believe that this will become a very effective tool for achieving the configuration and process control believed to be necessary for scientific instrument systems.« less

  11. [Development of methods and instruments for external quality assurance in inpatient parent-child rehabilitation and prevention].

    PubMed

    Neuderth, S; Lukasczik, M; Musekamp, G; Gerlich, C; Saupe-Heide, M; Löbmann, R; Vogel, H

    2013-02-01

    There so far is no standardized program for external quality assurance in inpatient parent-child prevention and rehabilitation in Germany. Therefore, instruments and methods of external quality assurance were developed and evaluated on behalf of the federal-level health insurance institutions. On the level of structure quality, a modular questionnaire for assessing structural features of rehabilitation/prevention centers, basic and allocation criteria as well as a checklist for visitations were developed. Structural data were collected in a nationwide survey of parent-child prevention and rehabilitation centers. Process and outcome quality data were collected in n=38 centers. Process quality was assessed using multiple methods (process-related structural features, case-related routine documentation, and incident-related patient questionnaires). Outcome quality was measured via patient questionnaires (n=1 799 patients). We used a multi-level modelling approach by adjusting relevant confounders on institutional and patient levels. The methods, instruments and analyzing procedures developed for measuring quality on the level of structure, processes and outcomes were adjusted in cooperation with all relevant stakeholders. Results are exemplarily presented for all quality assurance tools. For most of the risk-adjusted outcome parameters, we found no significant differences between institutions. For the first time, a comprehensive, standardized and generally applicable set of methods and instruments for routine use in comparative quality measurement of inpatient parent-child prevention and rehabilitation is available. However, it should be considered that the very heterogeneous field of family-oriented measures can not be covered entirely by an external quality assurance program. Therefore, methods and instruments have to be adapted continuously to the specifics of this area of health care and to new developments. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Developing an Assessment Instrument to Measure Early Elementary Teachers' Mathematical Knowledge for Teaching

    ERIC Educational Resources Information Center

    Schoen, Robert C.; Bray, Wendy; Wolfe, Christopher; Tazaz, Amanda M.; Nielsen, Lynne

    2017-01-01

    This study reports on the development and field study of K-TEEM, a web-based assessment instrument designed to measure mathematical knowledge for teaching (MKT) at the early elementary level. The development process involved alignment with early elementary curriculum standards, expert review of items and scoring criteria, cognitive interviews with…

  13. Concept of Science Data Management for the Korea Pathfinder Lunar Orbiter

    NASA Astrophysics Data System (ADS)

    Kim, Joo Hyeon

    2016-10-01

    South Korea has a plan to explore the Moon in 2018 or 2019. For the plan, the Korea Aerospace Research Institute which is a government funded research institute kicked off the Korea Lunar Exploration Development Program in January, 2016 in support of Ministry of Science, ICT and Future Planning, South Korea.As the 1st stage mission of the program, named as the Korea Pathfinder Lunar Orbiter(KPLO), will perform acquisition of high resolution images and science data for investigation of lunar environment as well as the core technology demonstration and validation for space explorations. The scientific instruments consists of three Korean domestic developed science instruments except an imaging instrument and several foreign provided instruments. We are developing a science data management plan to encourage scientific activities using science data acquired by the science instruments.I introduce the Korean domestic developed science instruments and present concept of the science data management plan for data delivery, processing, and distribution for the science instruments.

  14. Assessment of Work Performance (AWP)--development of an instrument.

    PubMed

    Sandqvist, Jan L; Törnquist, Kristina B; Henriksson, Chris M

    2006-01-01

    Adequate work assessments are a matter of importance both for individuals and society [5,29,31,38,40,46,52]. However, there is a lack of adequate and reliable instruments for use in work rehabilitation [14,15,20,21,31,44]. The purpose of this study was to develop and evaluate an observation instrument for assessing work performance, the AWP (Assessment of Work Performance). The purpose of the 14-item instrument is to assess the individual's observable working skills in three different areas: motor skills, process skills, and communication and interaction skills. This article describes the development and results of preliminary testing of the AWP. The testing indicates a satisfactory face validity and utility for the AWP and supports further research and testing of the instrument.

  15. Automation of processing and photometric data analysis for transiting exoplanets observed with ESO NIR instrument HAWK-I

    NASA Astrophysics Data System (ADS)

    Blažek, M.; Kabáth, P.; Klocová, T.; Skarka, M.

    2018-04-01

    Nowadays, when amount of data still increases, it is necessary to automatise their processing. State-of-the-art instruments are capable to produce even tens of thousands of images during a single night. One of them is HAWK-I that is a part of Very Large Telescope of European Southern Observatory. This instrument works in near-infrared band. In my Master thesis, I dealt with developing a pipeline to process data obtained by the instrument. It is written in Python programming language using commands of IRAF astronomical software and it is developed directly for "Fast Photometry Mode" of HAWK-I. In this mode, a large number of data has been obtained during secondary eclipses of exoplanets by their host star. The pipeline was tested by a data set from sorting of the images to making a light curve. The data of WASP-18 system contained almost 40 000 images observed by using a filter centered at 2.09 μm wavelength and there is a plan to process other data sets. A goal of processing of WASP-18 and the other data sets is consecutive analysis of exoplanetary atmospheres of the observed systems.

  16. An OSEE Based Portable Surface Contamination Monitor

    NASA Technical Reports Server (NTRS)

    Perey, Daniel F.

    1997-01-01

    Many industrial and aerospace processes involving the joining of materials, require sufficient surface cleanliness to insure proper bonding. Processes as diverse as painting, welding, or the soldering of electronic circuits will be compromised if prior inspection and removal of surface contaminants is inadequate. As process requirements become more stringent and the number of different materials and identified contaminants increases, various instruments and techniques have been developed for improved inspection. One such technique based on the principle of Optically Stimulated Electron Emission (OSEE) has been explored for a number of years as a tool for surface contamination monitoring. Some of the benefits of OSEE are: it's non-contacting; requires little operator training; and has very high contamination sensitivity. This paper describes the development of a portable OSEE based surface contamination monitor. The instrument is suitable for both hand-held and robotic inspections with either manual or automated control of instrument operation. In addition, instrument output data is visually displayed to the operator and may be output to an external computer for archiving or analysis.

  17. Plot-scale field experiment of surface hydrologic processes with EOS implications

    NASA Technical Reports Server (NTRS)

    Laymon, Charles A.; Macari, Emir J.; Costes, Nicholas C.

    1992-01-01

    Plot-scale hydrologic field studies were initiated at NASA Marshall Space Flight Center to a) investigate the spatial and temporal variability of surface and subsurface hydrologic processes, particularly as affected by vegetation, and b) develop experimental techniques and associated instrumentation methodology to study hydrologic processes at increasingly large spatial scales. About 150 instruments, most of which are remotely operated, have been installed at the field site to monitor ground atmospheric conditions, precipitation, interception, soil-water status, and energy flux. This paper describes the nature of the field experiment, instrumentation and sampling rationale, and presents preliminary findings.

  18. [Historical archives of Italian nephrology: The history of instrumentation in nephrology. Part I: Theoretical bases].

    PubMed

    Timio, M

    2002-01-01

    Microscopes and artificial kidneys have greatly influenced both diagnosis and therapy of renal diseases. Nonetheless, in tracing the influence of instrumentation on nephrology, as revealed by daily activity, we have to recognise the influence of science upon medical instruments. It is for this reason that, besides strictly clinical factors, the scientific factors that contributed to the development of modern nephrology have received considerable attention. Nobody can use an artificial kidney without bearing in mind the contribution of many segments of science. Each segment has a hypothesis in its historical growth, development and decline. The notion that the advancement of science was made possible by the increasing reliance measurements and other quantitative procedure is hardly a novel one. Moreover, it is rather obvious that the experimental process and the use of instrumentation played an important role in the history of nephrology. Measurements, experiments and the use of instruments were interrelated and represented many phases of the improvements made in diagnosis and therapeutics. Naturally, in the history and epistemology of nephrology instrumentation we find conceptual mistakes and erroneous approaches to the biological reality. However, according to Popper's teachings, mistakes are good for science as they give an extra kick to its growth and development. Medical instrumentation is an assembly of scientific theories; it also controls medical theories and promotes the development of new ones. In addition, it changed our approach to the patient. In the pre-physical era, medical practice was almost entirely an intellectual process based on medical theories that the patient was not expected to understand. In the period of physical examinations the physician included the sensual dimension (oral and visual process) and made direct contact with the patient. In the instrumentation period we experience the third type of examination, in which the physician went back to the position of having less contact with the patient. This separation is reminiscent of the pre-physical diagnosis.

  19. Development of ECT/UT inspection system for bottom mounted instrumentation nozzle of PWR reactor vessels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanaka, H.; Fukui, S.; Iwahashi, Y.

    1994-12-31

    The development of inspection technique and tool for Bottom Mounted Instrument (BMI) nozzle of PWR plant was performed for countermeasure of leakage accident at incore instrument nozzle of Hamaoka-1 (BWR). MHI achieved the following development, of which object was PWR Plant R/V: (1) development of ECT/UT Multi-sensored Probe; (2) development of Inspection System (3) development of Data Processing System. The Inspection System had been functionally tested using full scale mock-up. As the result of the functional test, this system was confirmed to be very effective, and assumed to be hopeful for the actual application on site.

  20. [Development of an evaluation instrument for service quality in nursing homes].

    PubMed

    Lee, Jia; Ji, Eun Sun

    2011-08-01

    The purposes of this study were to identify the factors influencing service quality in nursing homes, and to develop an evaluation instrument for service quality. A three-phase process was employed for the study. 1) The important factors to evaluate the service quality in nursing homes were identified through a literature review, panel discussion and focus group interview, 2) the evaluation instrument was developed, and 3) validity and reliability of the study instrument were tested by factor analysis, Pearson correlation coefficient, Cronbach's α and Cohen's Kappa. Factor analysis showed that the factors influencing service quality in nursing homes were healthcare, diet/assistance, therapy, environment and staff. To improve objectivity of the instrument, quantitative as well as qualitative evaluation approaches were adopted. The study instrument was developed with 30 items and showed acceptable construct validity. The criterion-related validity was a Pearson correlation coefficient of .85 in 151 care facilities. The internal consistency was Cronbach's α=.95. The instrument has acceptable validity and a high degree of reliability. Staff in nursing homes can continuously improve and manage their services using the results of the evaluation instrument.

  1. Production and Distribution of NASA MODIS Remote Sensing Products

    NASA Technical Reports Server (NTRS)

    Wolfe, Robert

    2007-01-01

    The two Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on-board NASA's Earth Observing System (EOS) Terra and Aqua satellites make key measurements for understanding the Earth's terrestrial ecosystems. Global time-series of terrestrial geophysical parameters have been produced from MODIS/Terra for over 7 years and for MODIS/Aqua for more than 4 1/2 years. These well calibrated instruments, a team of scientists and a large data production, archive and distribution systems have allowed for the development of a new suite of high quality product variables at spatial resolutions as fine as 250m in support of global change research and natural resource applications. This talk describes the MODIS Science team's products, with a focus on the terrestrial (land) products, the data processing approach and the process for monitoring and improving the product quality. The original MODIS science team was formed in 1989. The team's primary role is the development and implementation of the geophysical algorithms. In addition, the team provided feedback on the design and pre-launch testing of the instrument and helped guide the development of the data processing system. The key challenges the science team dealt with before launch were the development of algorithms for a new instrument and provide guidance of the large and complex multi-discipline processing system. Land, Ocean and Atmosphere discipline teams drove the processing system requirements, particularly in the area of the processing loads and volumes needed to daily produce geophysical maps of the Earth at resolutions as fine as 250 m. The processing system had to handle a large number of data products, large data volumes and processing loads, and complex processing requirements. Prior to MODIS, daily global maps from heritage instruments, such as Advanced Very High Resolution Radiometer (AVHRR), were not produced at resolutions finer than 5 km. The processing solution evolved into a combination of processing the lower level (Level 1) products and the higher level discipline specific Land and Atmosphere products in the MODIS Science Investigator Lead Processing System (SIPS), the MODIS Adaptive Processing System (MODAPS), and archive and distribution of the Land products to the user community by two of NASA s EOS Distributed Active Archive Centers (DAACs). Recently, a part of MODAPS, the Level 1 and Atmosphere Archive and Distribution System (LAADS), took over the role of archiving and distributing the Level 1 and Atmosphere products to the user community.

  2. Understanding practice change in community pharmacy: a qualitative research instrument based on organisational theory.

    PubMed

    Roberts, Alison S; Hopp, Trine; Sørensen, Ellen Westh; Benrimoj, Shalom I; Chen, Timothy F; Herborg, Hanne; Williams, Kylie; Aslani, Parisa

    2003-10-01

    The past decade has seen a notable shift in the practice of pharmacy, with a strong focus on the provision of cognitive pharmaceutical services (CPS) by community pharmacists. The benefits of these services have been well documented, yet their uptake appears to be slow. Various strategies have been developed to overcome barriers to the implementation of CPS, with varying degrees of success, and little is known about the sustainability of the practice changes they produce. Furthermore, the strategies developed are often specific to individual programs or services, and their applicability to other CPS has not been explored. There seems to be a need for a flexible change management model for the implementation and dissemination of a range of CPS, but before it can be developed, a better understanding of the change process is required. This paper describes the development of a qualitative research instrument that may be utilised to investigate practice change in community pharmacy. Specific objectives included gaining knowledge about the circumstances surrounding attempts to implement CPS, and understanding relationships that are important to the change process. Organisational theory provided the conceptual framework for development of the qualitative research instrument, within which two theories were used to give insight into the change process: Borum's theory of organisational change, which categorizes change strategies as rational, natural, political or open; and Social Network Theory, which helps identify and explain the relationships between key people involved in the change process. A semi-structured affecting practice change found in the literature that warranted further investigation with the theoretical perspectives of organisational change and social networks. To address the research objectives, the instrument covered four broad themes: roles, experiences, strategies and networks. The qualitative research instrument developed in this study provides a starting point for future research to lead to a description and understanding of practice change in community pharmacy, and subsequent development of models for the sustainable implementation of CPS.

  3. The challenges of developing an instrument to assess health provider motivation at primary care level in rural Burkina Faso, Ghana and Tanzania

    PubMed Central

    Prytherch, Helen; Leshabari, Melkidezek T.; Wiskow, Christiane; Aninanya, Gifty A.; Kakoko, Deodatus C.V.; Kagoné, Moubassira; Burghardt, Juliane; Kynast-Wolf, Gisela; Marx, Michael; Sauerborn, Rainer

    2012-01-01

    Background The quality of health care depends on the competence and motivation of the health workers that provide it. In the West, several tools exist to measure worker motivation, and some have been applied to the health sector. However, none have been validated for use in sub-Saharan Africa. The complexity of such tools has also led to concerns about their application at primary care level. Objective To develop a common instrument to monitor any changes in maternal and neonatal health (MNH) care provider motivation resulting from the introduction of pilot interventions in rural, primary level facilities in Ghana, Burkina Faso, and Tanzania. Design Initially, a conceptual framework was developed. Based upon this, a literature review and preliminary qualitative research, an English-language instrument was developed and validated in an iterative process with experts from the three countries involved. The instrument was then piloted in Ghana. Reliability testing and exploratory factor analysis were used to produce a final, parsimonious version. Results and discussion This paper describes the actual process of developing the instrument. Consequently, the concepts and items that did not perform well psychometrically at pre-test are first presented and discussed. The final version of the instrument, which comprises 42 items for self-assessment and eight for peer-assessment, is then shown. This is followed by a presentation and discussion of the findings from first use of the instrument with MNH providers from 12 rural, primary level facilities in each of the three countries. Conclusions It is possible to undertake work of this nature at primary health care level, particularly if the instruments are kept as straightforward as possible and well introduced. However, their development requires very lengthy preparatory periods. The effort needed to adapt such instruments for use in different countries within the region of sub-Saharan Africa should not be underestimated. PMID:23043816

  4. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on themore » ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides. (JGB)« less

  5. Using qualitative methods to develop a contextually tailored instrument: Lessons learned.

    PubMed

    Lee, Haeok; Kiang, Peter; Kim, Minjin; Semino-Asaro, Semira; Colten, Mary Ellen; Tang, Shirley S; Chea, Phala; Peou, Sonith; Grigg-Saito, Dorcas C

    2015-01-01

    To develop a population-specific instrument to inform hepatitis B virus (HBV) and human papilloma virus (HPV) prevention education and intervention based on data and evidence obtained from the targeted population of Khmer mothers reflecting their socio-cultural and health behaviors. The principles of community-based participatory research (CBPR) guided the development of a standardized survey interview. Four stages of development and testing of the survey instrument took place in order to inform the quantitative health survey used to collect data in stage five of the project. This article reports only on Stages 1-4. This process created a new quantitative measure of HBV and HPV prevention behavior based on the revised Network Episode Model and informed by the targeted population. The CBPR method facilitated the application and translation of abstract theoretical ideas of HBV and HPV prevention behavior into culturally-relevant words and expressions of Cambodian Americans (CAs). The design of an instrument development process that accounts for distinctive socio-cultural backgrounds of CA refugee/immigrant women provides a model for use in developing future health surveys that are intended to aid minority-serving health care professionals and researchers as well as targeted minority populations.

  6. Using qualitative methods to develop a contextually tailored instrument: Lessons learned

    PubMed Central

    Lee, Haeok; Kiang, Peter; Kim, Minjin; Semino-Asaro, Semira; Colten, Mary Ellen; Tang, Shirley S.; Chea, Phala; Peou, Sonith; Grigg-Saito, Dorcas C.

    2015-01-01

    Objective: To develop a population-specific instrument to inform hepatitis B virus (HBV) and human papilloma virus (HPV) prevention education and intervention based on data and evidence obtained from the targeted population of Khmer mothers reflecting their socio-cultural and health behaviors. Methods: The principles of community-based participatory research (CBPR) guided the development of a standardized survey interview. Four stages of development and testing of the survey instrument took place in order to inform the quantitative health survey used to collect data in stage five of the project. This article reports only on Stages 1-4. Results: This process created a new quantitative measure of HBV and HPV prevention behavior based on the revised Network Episode Model and informed by the targeted population. The CBPR method facilitated the application and translation of abstract theoretical ideas of HBV and HPV prevention behavior into culturally-relevant words and expressions of Cambodian Americans (CAs). Conclusions: The design of an instrument development process that accounts for distinctive socio-cultural backgrounds of CA refugee/immigrant women provides a model for use in developing future health surveys that are intended to aid minority-serving health care professionals and researchers as well as targeted minority populations. PMID:27981114

  7. The Assessment, Development, Assurance Pharmacist's Tool (ADAPT) for ensuring quality implementation of health promotion programs.

    PubMed

    Truong, Hoai-An; Taylor, Catherine R; DiPietro, Natalie A

    2012-02-10

    To develop and validate the Assessment, Development, Assurance Pharmacist's Tool (ADAPT), an instrument for pharmacists and student pharmacists to use in developing and implementing health promotion programs. The 36-item ADAPT instrument was developed using the framework of public health's 3 core functions (assessment, policy development, and assurance) and 10 essential services. The tool's content and usage was assessed and conducted through peer-review and initial validity testing processes. Over 20 faculty members, preceptors, and student pharmacists at 5 institutions involved in planning and implementing health promotion initiatives reviewed the instrument and conducted validity testing. The instrument took approximately 15 minutes to complete and the findings resulted in changes and improvements to elements of the programs evaluated. The ADAPT instrument fills a need to more effectively plan, develop, implement, and evaluate pharmacist-directed public health programs that are evidence-based, high-quality, and compliant with laws and regulations and facilitates documentation of pharmacists' contributions to public health.

  8. Operations and Data Processing for the Planck Low-Frequency Instrument: Design Strategies and Practical Experience

    NASA Astrophysics Data System (ADS)

    Pasian, F.; Zacchei, A.; Frailis, M.; Galeotta, S.; Maris, M.; Tavagnacco, D.; Vuerli, C.; Tuerler, M.; Rohlfs, R.; Morisset, N.; Meharga, M.; Ensslin, T. A.; Knoche, J.; Gregorio, A.; Maino, D.; Mennella, A.; Tomasi, M.; Cuttaia, F.; Morgante, G.; Terenzi, L.; Maggio, G.; Gasparo, F.; Franceschi, E.

    2012-09-01

    Planck is an ESA mission launched in May 2009, which is mapping the microwave sky in nine frequencies and accurately measuring the anisotropies of the Cosmic Microwave Background (CMB) with its complement of two instruments (HFI and LFI), covering respectively the far infrared and the radio domains. The operations and data processing of the Planck instruments are carried out by Data Processing Centers, one for each instrument. The DPCs need to support both a day-by-day quasi-real-time calibration workflow and high-throughput pipelines for a high-volume data flow. The LFI DPC has been designed to be a centralized facility built by geographically distributed institutions, in a funding scenario based on multiple funding agencies and, in most cases, on a fixed budget in the presence of launch delays. A strategy for managing effectively the distributed and collaborative software development and maintenance has been developed, based on the use of open source and off-the-shelf software, and on the reuse of systems developed ad-hoc for other missions. Product and quality assurance has been supported throughout development, integration and testing. The effectiveness of the design choices has been proven by the readiness of the system at launch time and by the extremely smooth operations phase.

  9. Digital Signal Processing by Virtual Instrumentation of a MEMS Magnetic Field Sensor for Biomedical Applications

    PubMed Central

    Juárez-Aguirre, Raúl; Domínguez-Nicolás, Saúl M.; Manjarrez, Elías; Tapia, Jesús A.; Figueras, Eduard; Vázquez-Leal, Héctor; Aguilera-Cortés, Luz A.; Herrera-May, Agustín L.

    2013-01-01

    We present a signal processing system with virtual instrumentation of a MEMS sensor to detect magnetic flux density for biomedical applications. This system consists of a magnetic field sensor, electronic components implemented on a printed circuit board (PCB), a data acquisition (DAQ) card, and a virtual instrument. It allows the development of a semi-portable prototype with the capacity to filter small electromagnetic interference signals through digital signal processing. The virtual instrument includes an algorithm to implement different configurations of infinite impulse response (IIR) filters. The PCB contains a precision instrumentation amplifier, a demodulator, a low-pass filter (LPF) and a buffer with operational amplifier. The proposed prototype is used for real-time non-invasive monitoring of magnetic flux density in the thoracic cage of rats. The response of the rat respiratory magnetogram displays a similar behavior as the rat electromyogram (EMG). PMID:24196434

  10. MSL Chemistry and Mineralogy X-Ray Diffraction X-Ray Fluorescence (CheMin) Instrument

    NASA Technical Reports Server (NTRS)

    Zimmerman, Wayne; Blake, Dave; Harris, William; Morookian, John Michael; Randall, Dave; Reder, Leonard J.; Sarrazin, Phillipe

    2013-01-01

    This paper provides an overview of the Mars Science Laboratory (MSL) Chemistry and Mineralogy Xray Diffraction (XRD), X-ray Fluorescence (XRF) (CheMin) Instrument, an element of the landed Curiosity rover payload, which landed on Mars in August of 2012. The scientific goal of the MSL mission is to explore and quantitatively assess regions in Gale Crater as a potential habitat for life - past or present. The CheMin instrument will receive Martian rock and soil samples from the MSL Sample Acquisition/Sample Processing and Handling (SA/SPaH) system, and process it utilizing X-Ray spectroscopy methods to determine mineral composition. The Chemin instrument will analyze Martian soil and rocks to enable scientists to investigate geophysical processes occurring on Mars. The CheMin science objectives and proposed surface operations are described along with the CheMin hardware with an emphasis on the system engineering challenges associated with developing such a complex instrument.

  11. Digital signal processing by virtual instrumentation of a MEMS magnetic field sensor for biomedical applications.

    PubMed

    Juárez-Aguirre, Raúl; Domínguez-Nicolás, Saúl M; Manjarrez, Elías; Tapia, Jesús A; Figueras, Eduard; Vázquez-Leal, Héctor; Aguilera-Cortés, Luz A; Herrera-May, Agustín L

    2013-11-05

    We present a signal processing system with virtual instrumentation of a MEMS sensor to detect magnetic flux density for biomedical applications. This system consists of a magnetic field sensor, electronic components implemented on a printed circuit board (PCB), a data acquisition (DAQ) card, and a virtual instrument. It allows the development of a semi-portable prototype with the capacity to filter small electromagnetic interference signals through digital signal processing. The virtual instrument includes an algorithm to implement different configurations of infinite impulse response (IIR) filters. The PCB contains a precision instrumentation amplifier, a demodulator, a low-pass filter (LPF) and a buffer with operational amplifier. The proposed prototype is used for real-time non-invasive monitoring of magnetic flux density in the thoracic cage of rats. The response of the rat respiratory magnetogram displays a similar behavior as the rat electromyogram (EMG).

  12. Actual curriculum development practices instrument: Testing for factorial validity

    NASA Astrophysics Data System (ADS)

    Foi, Liew Yon; Bakar, Kamariah Abu; Hamzah, Mohd Sahandri Gani; Alwi, Nor Hayati

    2014-09-01

    The Actual Curriculum Development Practices Instrument (ACDP-I) was developed and the factorial validity of the ACDP-I was tested (n = 107) using exploratory factor analysis procedures in the earlier work of [1]. Despite the ACDP-I appears to be content and construct valid instrument with very high internal reliability qualities for using in Malaysia, the accumulated evidences are still needed to provide a sound scientific basis for the proposed score interpretations. Therefore, the present study addresses this concern by utilising the confirmatory factor analysis to further confirm the theoretical structure of the variable Actual Curriculum Development Practices (ACDP) and enrich the psychometrical properties of ACDP-I. Results of this study have practical implication to both researchers and educators whose concerns focus on teachers' classroom practices and the instrument development and validation process.

  13. Development of Curricula for Nuclear Radiation Protection, Nuclear Instrumentation, and Nuclear Materials Processing Technologies. Final Report.

    ERIC Educational Resources Information Center

    Hull, Daniel M.

    A study was conducted to assist two-year postsecondary educational institutions in providing technical specialty courses for preparing nuclear technicians. As a result of project activities, curricula have been developed for five categories of nuclear technicians and operators: (1) radiation protection technician, (2) nuclear instrumentation and…

  14. Understanding Gender Differences in Anxiety: The Mediating Effects of Instrumentality and Mastery

    ERIC Educational Resources Information Center

    Zalta, Alyson K.; Chambless, Dianne L.

    2012-01-01

    Developing a better understanding of modifiable psychological factors that account for gender differences in anxiety may provide insight into interventions that can be used to target these risk processes. The authors developed a mediational model to examine the degree to which gender differences in anxiety are explained by instrumentality and…

  15. Evaluation of telerobotic systems using an instrumented task board

    NASA Technical Reports Server (NTRS)

    Carroll, John D.; Gierow, Paul A.; Bryan, Thomas C.

    1991-01-01

    An instrumented task board was developed at NASA Marshall Space Flight Center (MSFC). An overview of the task board design, and current development status is presented. The task board was originally developed to evaluate operator performance using the Protoflight Manipulator Arm (PFMA) at MSFC. The task board evaluates tasks for Orbital Replacement Unit (ORU), fluid connect and transfers, electrical connect/disconnect, bolt running, and other basic tasks. The instrumented task board measures the 3-D forces and torques placed on the board, determines the robot arm's 3-D position relative to the task board using IR optics, and provides the information in real-time. The PFMA joint input signals can also be measured from a breakout box to evaluate the sensitivity or response of the arm operation to control commands. The data processing system provides the capability for post processing of time-history graphics and plots of the PFMA positions, the operator's actions, and the PFMA servo reactions in addition to real-time force/torque data presentation. The instrumented task board's most promising use is developing benchmarks for NASA centers for comparison and evaluation of telerobotic performance.

  16. A recent U.S. patent process for a musical instrument

    NASA Astrophysics Data System (ADS)

    Baecker, James I.

    2005-09-01

    The ins and outs of going from a novel musical instrument concept to issuance of a U.S. patent. The technical work performed included the development of a musical instrument based on space-frame body construction and a definition of the instrument body's resonance characteristics. The result required a description of the invention and communication with the patent attorney and conveying a correct perception of the invention to the U.S. Patent Office. This presentation describes several technical, practical, legal, and commercial issues encountered during the patent process by the inventors and their business entity. On 7 September 2004, U.S. Patent No. 6,787,688 for a musical instrument was issued and assigned by the inventors to Harmos Music, Ltd.

  17. Development of an inter-professional screening instrument for cancer patients' education process.

    PubMed

    Vaartio-Rajalin, Heli; Huumonen, Tuula; Iire, Liisa; Jekunen, Antti; Leino-Kilpi, Helena; Minn, Heikki; Paloniemi, Jenni; Zabalegui, Adelaida

    2016-02-01

    The aim of this paper is to describe the development of an inter-professional screening instrument for cancer patients' cognitive resources, knowledge expectations and inter-professional collaboration within patient education. Four empirical datasets during 2012-2014 were analyzed in order to identify main categories, subcategories and items for inter-professional screening instrument. Our inter-professional screening instrument integrates the critical moments of cancer patient education and the knowledge expectation types obtained from patient datasets to assessment of patients' cognitive resources, knowledge expectations and comprehension; and intra; and inter-professional. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Development and Validation of an Instrument to Measure University Students' Biotechnology Attitude

    NASA Astrophysics Data System (ADS)

    Erdogan, Mehmet; Özel, Murat; Uşak, Muhammet; Prokop, Pavol

    2009-06-01

    The impact of biotechnologies on peoples' everyday lives continuously increases. Measuring young peoples' attitudes toward biotechnologies is therefore very important and its results are useful not only for science curriculum developers and policy makers, but also for producers and distributors of genetically modified products. Despite of substantial number of instruments which focused on measuring student attitudes toward biotechnology, a majority of them were not rigorously validated. This study deals with the development and validation of an attitude questionnaire toward biotechnology. Detailed information on development and validation process of the instrument is provided. Data gathered from 326 university students provided evidence for the validity and reliability of the new instrument which consists of 28 attitude items on a five point likert type scale. It is believed that the instrument will serve as a valuable tool for both instructors and researchers in science education to assess students' biotechnology attitudes.

  19. Portable dynamic fundus instrument

    NASA Technical Reports Server (NTRS)

    Taylor, Gerald R. (Inventor); Meehan, Richard T. (Inventor); Hunter, Norwood R. (Inventor); Caputo, Michael P. (Inventor); Gibson, C. Robert (Inventor)

    1992-01-01

    A portable diagnostic image analysis instrument is disclosed for retinal funduscopy in which an eye fundus image is optically processed by a lens system to a charge coupled device (CCD) which produces recordable and viewable output data and is simultaneously viewable on an electronic view finder. The fundus image is processed to develop a representation of the vessel or vessels from the output data.

  20. WFF TOPEX Software Documentation Altimeter Instrument File (AIF) Processing, October 1998. Volume 3

    NASA Technical Reports Server (NTRS)

    Lee, Jeffrey; Lockwood, Dennis

    2003-01-01

    This document is a compendium of the WFF TOPEX Software Development Team's knowledge regarding Sensor Data Record (SDR) Processing. It includes many elements of a requirements document, a software specification document, a software design document, and a user's manual. In the more technical sections, this document assumes the reader is familiar with TOPEX and instrument files.

  1. Development and Initial Validation of a Questionnaire to Assess the Reading Beliefs of Undergraduate Students: The "Cuestionario de Creencias Sobre la Lectura"

    ERIC Educational Resources Information Center

    Lordán, Eva; Solé, Isabel; Beltran, Francesc S.

    2017-01-01

    The aim of this research was to develop a new questionnaire for exploring the reading beliefs of undergraduate students, because the only currently available instrument has conceptual and methodological limitations. The paper describes the process of developing the instrument and presents a range of psychometric data obtained from a sample of 558…

  2. Prioritizing guideline topics: development and evaluation of a practical tool.

    PubMed

    Ketola, Eeva; Toropainen, Erja; Kaila, Minna; Luoto, Riitta; Mäkelä, Marjukka

    2007-08-01

    A clear process for selecting and adopting clinical practice guidelines in the new topic areas is needed. The aim of this study is to design and develop a practical tool to assess guideline topics that have been suggested to the organization responsible for producing guidelines. We carried out an iterative development, feasibility and validation study of a guideline topic prioritization tool. The setting included the guideline producer organization and the tax-funded health care system. In the first stage of the tool development, participants were researchers, members of the Current Care Board and experts from health care organizations. In the second stage, the evaluation was done internally within the project by three independent reviewers. The main outcome measures were responses to an evaluation questionnaire, qualitative process feedback and analysis of the performance of the instrument on a random set of guidelines. Evaluations by three independent reviewers revealed good agreement and face validity with respect to its feasibility as a planning tool at the guideline board level. Feedback from board members suggested that the instrument is useful in prioritizing guideline topics. This instrument was accepted for use by the Board. Further developments are needed to ensure feedback and acceptability of the instrument by those proposing topics.

  3. The South African Astronomical Observatory instrumentation software architecture and the SHOC instruments

    NASA Astrophysics Data System (ADS)

    van Gend, Carel; Lombaard, Briehan; Sickafoose, Amanda; Whittal, Hamish

    2016-07-01

    Until recently, software for instruments on the smaller telescopes at the South African Astronomical Observatory (SAAO) has not been designed for remote accessibility and frequently has not been developed using modern software best-practice. We describe a software architecture we have implemented for use with new and upgraded instruments at the SAAO. The architecture was designed to allow for multiple components and to be fast, reliable, remotely- operable, support different user interfaces, employ as much non-proprietary software as possible, and to take future-proofing into consideration. Individual component drivers exist as standalone processes, communicating over a network. A controller layer coordinates the various components, and allows a variety of user interfaces to be used. The Sutherland High-speed Optical Cameras (SHOC) instruments incorporate an Andor electron-multiplying CCD camera, a GPS unit for accurate timing and a pair of filter wheels. We have applied the new architecture to the SHOC instruments, with the camera driver developed using Andor's software development kit. We have used this to develop an innovative web-based user-interface to the instrument.

  4. Development of an Imaging Fourier Transform Spectrometer

    DTIC Science & Technology

    1986-05-01

    during multiple tests or concurrently applying many identical instrument systems to a single test. These difficult, expensive, and time-consuming...processes would introduce AEDC-TR-86-17 uncertainties due to nonstationary sources and instrument instability associated with multiple firings or... multiple instruments. For even moderate spatial, spectral, and temporal resolution, none of the previously mentioned approaches is reasonable. The

  5. An integrative research review of instruments measuring religious involvement: implications for nursing research with African Americans.

    PubMed

    Mokel, Melissa Jennifer; Shellman, Juliette M

    2013-01-01

    Many instruments in which religious involvement is measured often (a) contain unclear, poorly developed constructs; (b) lack methodological rigor in scale development; and (c) contain language and content culturally incongruent with the religious experiences of diverse ethnic groups. The primary aims of this review were to (a) synthesize the research on instruments designed to measure religious involvement, (b) evaluate the methodological quality of instruments that measure religious involvement, and (c) examine these instruments for conceptual congruency with African American religious involvement. An updated integrative research review method guided the process (Whittemore & Knafl, 2005). 152 articles were reviewed and 23 articles retrieved. Only 3 retained instruments were developed under methodologically rigorous conditions. All 3 instruments were congruent with a conceptual model of African American religious involvement. The Fetzer Multidimensional Measure of Religious Involvement and Spirituality (FMMRS; Idler et al., 2003) was found to have favorable characteristics. Further examination and psychometric testing is warranted to determine its acceptability, readability, and cultural sensitivity in an African American population.

  6. Wave data processing toolbox manual

    USGS Publications Warehouse

    Sullivan, Charlene M.; Warner, John C.; Martini, Marinna A.; Lightsom, Frances S.; Voulgaris, George; Work, Paul

    2006-01-01

    Researchers routinely deploy oceanographic equipment in estuaries, coastal nearshore environments, and shelf settings. These deployments usually include tripod-mounted instruments to measure a suite of physical parameters such as currents, waves, and pressure. Instruments such as the RD Instruments Acoustic Doppler Current Profiler (ADCP(tm)), the Sontek Argonaut, and the Nortek Aquadopp(tm) Profiler (AP) can measure these parameters. The data from these instruments must be processed using proprietary software unique to each instrument to convert measurements to real physical values. These processed files are then available for dissemination and scientific evaluation. For example, the proprietary processing program used to process data from the RD Instruments ADCP for wave information is called WavesMon. Depending on the length of the deployment, WavesMon will typically produce thousands of processed data files. These files are difficult to archive and further analysis of the data becomes cumbersome. More imperative is that these files alone do not include sufficient information pertinent to that deployment (metadata), which could hinder future scientific interpretation. This open-file report describes a toolbox developed to compile, archive, and disseminate the processed wave measurement data from an RD Instruments ADCP, a Sontek Argonaut, or a Nortek AP. This toolbox will be referred to as the Wave Data Processing Toolbox. The Wave Data Processing Toolbox congregates the processed files output from the proprietary software into two NetCDF files: one file contains the statistics of the burst data and the other file contains the raw burst data (additional details described below). One important advantage of this toolbox is that it converts the data into NetCDF format. Data in NetCDF format is easy to disseminate, is portable to any computer platform, and is viewable with public-domain freely-available software. Another important advantage is that a metadata structure is embedded with the data to document pertinent information regarding the deployment and the parameters used to process the data. Using this format ensures that the relevant information about how the data was collected and converted to physical units is maintained with the actual data. EPIC-standard variable names have been utilized where appropriate. These standards, developed by the NOAA Pacific Marine Environmental Laboratory (PMEL) (http://www.pmel.noaa.gov/epic/), provide a universal vernacular allowing researchers to share data without translation.

  7. Infrared Spectroscopic Imaging: The Next Generation

    PubMed Central

    Bhargava, Rohit

    2013-01-01

    Infrared (IR) spectroscopic imaging seemingly matured as a technology in the mid-2000s, with commercially successful instrumentation and reports in numerous applications. Recent developments, however, have transformed our understanding of the recorded data, provided capability for new instrumentation, and greatly enhanced the ability to extract more useful information in less time. These developments are summarized here in three broad areas— data recording, interpretation of recorded data, and information extraction—and their critical review is employed to project emerging trends. Overall, the convergence of selected components from hardware, theory, algorithms, and applications is one trend. Instead of similar, general-purpose instrumentation, another trend is likely to be diverse and application-targeted designs of instrumentation driven by emerging component technologies. The recent renaissance in both fundamental science and instrumentation will likely spur investigations at the confluence of conventional spectroscopic analyses and optical physics for improved data interpretation. While chemometrics has dominated data processing, a trend will likely lie in the development of signal processing algorithms to optimally extract spectral and spatial information prior to conventional chemometric analyses. Finally, the sum of these recent advances is likely to provide unprecedented capability in measurement and scientific insight, which will present new opportunities for the applied spectroscopist. PMID:23031693

  8. FHR Process Instruments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holcomb, David Eugene

    2015-01-01

    Fluoride salt-cooled High temperature Reactors (FHRs) are entering into early phase engineering development. Initial candidate technologies have been identified to measure all of the required process variables. The purpose of this paper is to describe the proposed measurement techniques in sufficient detail to enable assessment of the proposed instrumentation suite and to support development of the component technologies. This paper builds upon the instrumentation chapter of the recently published FHR technology development roadmap. Locating instruments outside of the intense core radiation and high-temperature fluoride salt environment significantly decreases their environmental tolerance requirements. Under operating conditions, FHR primary coolant salt ismore » a transparent, low-vapor-pressure liquid. Consequently, FHRs can employ standoff optical measurements from above the salt pool to assess in-vessel conditions. For example, the core outlet temperature can be measured by observing the fuel s blackbody emission. Similarly, the intensity of the core s Cerenkov glow indicates the fission power level. Short-lived activation of the primary coolant provides another means for standoff measurements of process variables. The primary coolant flow and neutron flux can be measured using gamma spectroscopy along the primary coolant piping. FHR operation entails a number of process measurements. Reactor thermal power and core reactivity are the most significant variables for process control. Thermal power can be determined by measuring the primary coolant mass flow rate and temperature rise across the core. The leading candidate technologies for primary coolant temperature measurement are Au-Pt thermocouples and Johnson noise thermometry. Clamp-on ultrasonic flow measurement, that includes high-temperature tolerant standoffs, is a potential coolant flow measurement technique. Also, the salt redox condition will be monitored as an indicator of its corrosiveness. Both electrochemical techniques and optical spectroscopy are candidate fluoride salt redox measurement methods. Coolant level measurement can be performed using radar-level gauges located in standpipes above the reactor vessel. While substantial technical development remains for most of the instruments, industrially compatible instruments based upon proven technology can be reasonably extrapolated from the current state of the art.« less

  9. Integrating High-Throughput Parallel Processing Framework and Storage Area Network Concepts Into a Prototype Interactive Scientific Visualization Environment for Hyperspectral Data

    NASA Astrophysics Data System (ADS)

    Smuga-Otto, M. J.; Garcia, R. K.; Knuteson, R. O.; Martin, G. D.; Flynn, B. M.; Hackel, D.

    2006-12-01

    The University of Wisconsin-Madison Space Science and Engineering Center (UW-SSEC) is developing tools to help scientists realize the potential of high spectral resolution instruments for atmospheric science. Upcoming satellite spectrometers like the Cross-track Infrared Sounder (CrIS), experimental instruments like the Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) and proposed instruments like the Hyperspectral Environmental Suite (HES) within the GOES-R project will present a challenge in the form of the overwhelmingly large amounts of continuously generated data. Current and near-future workstations will have neither the storage space nor computational capacity to cope with raw spectral data spanning more than a few minutes of observations from these instruments. Schemes exist for processing raw data from hyperspectral instruments currently in testing, that involve distributed computation across clusters. Data, which for an instrument like GIFTS can amount to over 1.5 Terabytes per day, is carefully managed on Storage Area Networks (SANs), with attention paid to proper maintenance of associated metadata. The UW-SSEC is preparing a demonstration integrating these back-end capabilities as part of a larger visualization framework, to assist scientists in developing new products from high spectral data, sourcing data volumes they could not otherwise manage. This demonstration focuses on managing storage so that only the data specifically needed for the desired product are pulled from the SAN, and on running computationally expensive intermediate processing on a back-end cluster, with the final product being sent to a visualization system on the scientist's workstation. Where possible, existing software and solutions are used to reduce cost of development. The heart of the computing component is the GIFTS Information Processing System (GIPS), developed at the UW- SSEC to allow distribution of processing tasks such as conversion of raw GIFTS interferograms into calibrated radiance spectra, and retrieving temperature and water vapor content atmospheric profiles from these spectra. The hope is that by demonstrating the capabilities afforded by a composite system like the one described here, scientists can be convinced to contribute further algorithms in support of this model of computing and visualization.

  10. Development and evaluation of an instrument to measure parental satisfaction with quality of care in neonatal follow-up.

    PubMed

    Butt, Michelle L; Pinelli, Janet; Boyle, Michael H; Thomas, Helen; Hunsberger, Mabel; Saigal, Saroj; Lee, David S; Fanning, Jamie K; Austin, Patricia

    2009-02-01

    The goal of this study was to develop and subsequently evaluate the psychometric properties of a new discriminative instrument to measure parental satisfaction with the quality of care provided in neonatal follow-up (NFU) programs. The methodological framework for developing and evaluating measurement scales described by Streiner and Norman (Health Measurement Scales: A Practical Guide to Their Development and Use. 3rd ed. New York: Oxford University Press; 2003) was used for the study. Informing the phases of the research was a sample of 24 health care professionals and 381 parents who use NFU services. A comprehensive list of items representing the construct, parental satisfaction with quality of care, was generated from published reliable and valid instruments, research studies, focus groups with health care experts, and focus groups with parents. Using a clinimetric approach, the 62 items generated were reduced to 39 items based on parents' ratings of importance and refinement of the items by the research team. After content validation and pretesting, the instrument was tested with parents and underwent item-analysis. The resulting 16-item instrument was composed of 2 subscales, Process and Outcomes. Evaluation of the instrument's psychometric properties indicated adequate test-retest reliability (intraclass correlation coefficient = 0.72) and internal consistency (Process subscale, alpha = 0.77; Outcomes subscale, alpha = 0.90; overall instrument, alpha = 0.90), as well as good content and construct validity. A confirmatory factor analysis supported the multidimensionality of the construct. This new instrument provides clinicians and policy-makers with a tool to assess parental satisfaction with the quality of care in NFU, so areas of dissatisfaction can be identified and changes implemented to optimize service provision.

  11. Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments.

    PubMed

    Alapati, Satish B; Brantley, William A; Iijima, Masahiro; Clark, William A T; Kovarik, Libor; Buie, Caesar; Liu, Jie; Ben Johnson, William

    2009-11-01

    A novel thermomechanical processing procedure has been developed that yields a superelastic (SE) nickel-titanium (NiTi) wire (M-Wire) that laboratory testing shows has improved mechanical properties compared with conventional SE austenitic NiTi wires used for manufacture of rotary instruments. The objective of this study was to determine the origin of the improved mechanical properties. Specimens from 2 batches of M-Wire prepared under different processing conditions and from 1 batch of standard-processed SE wire for rotary instruments were examined by scanning transmission electron microscopy, temperature-modulated differential scanning calorimetry, micro-x-ray diffraction, and scanning electron microscopy with x-ray energy-dispersive spectrometric analyses. The processing for M-Wire yields a microstructure containing martensite, that the proportions of NiTi phases depend on processing conditions, and that the microstructure exhibits pronounced evidence of alloy strengthening. The presence of Ti(2)Ni precipitates in both microstructures indicates that M-Wire and the conventional SE wire for rotary instruments are titanium-rich.

  12. Development an Instrument to Measure University Students' Attitude towards E-Learning

    ERIC Educational Resources Information Center

    Mehra, Vandana; Omidian, Faranak

    2012-01-01

    The study of student's attitude towards e-learning can in many ways help managers better prepare in light of e-learning for the future. This article describes the process of the development of an instrument to measure university students' attitude towards e-learning. The scale was administered to 200 University students from two countries (India…

  13. Development and Analysis of an Instrument to Assess Student Understanding of GOB Chemistry Knowledge Relevant to Clinical Nursing Practice

    ERIC Educational Resources Information Center

    Brown, Corina E.; Hyslop, Richard M.; Barbera, Jack

    2015-01-01

    The General, Organic, and Biological Chemistry Knowledge Assessment (GOB-CKA) is a multiple-choice instrument designed to assess students' understanding of the chemistry topics deemed important to clinical nursing practice. This manuscript describes the development process of the individual items along with a psychometric evaluation of the…

  14. Development of an Instrument to Measure Students' Attitudes towards Piano Practice

    ERIC Educational Resources Information Center

    Umuzdas, Mehmet Serkan

    2015-01-01

    Practicing the piano is a systematic part of the instrument-learning process. It contains all development practices from the analysis of the work to the improvement of performance. Students usually practice the piano as a preparation for performing in courses, exams, or on stage and they do it individually. The mentality which emerges during the…

  15. A Portable Surface Contamination Monitor Based on the Principle of Optically Stimulated Electron Emission (OSEE)

    NASA Technical Reports Server (NTRS)

    Perey, D. F.

    1996-01-01

    Many industrial and aerospace processes involving the joining of materials, require sufficient surface cleanliness to insure proper bonding. Processes as diverse as painting, welding, or the soldering of electronic circuits will be compromised if prior inspection and removal of surface contaminants is inadequate. As process requirements become more stringent and the number of different materials and identified contaminants increases, various instruments and techniques have been developed for improved inspection. One such technique, based on the principle of Optically Stimulated Electron Emission (OSEE), has been explored for a number of years as a tool for surface contamination monitoring. Some of the benefits of OSEE are: it is non-contacting; requires little operator training; and has very high contamination sensitivity. This paper describes the development of a portable OSEE based surface contamination monitor. The instrument is suitable for both hand-held and robotic inspections with either manual or automated control of instrument operation. In addition, instrument output data is visually displayed to the operator and may be sent to an external computer for archiving or analysis.

  16. Subjective health literacy: Development of a brief instrument for school-aged children.

    PubMed

    Paakkari, Olli; Torppa, Minna; Kannas, Lasse; Paakkari, Leena

    2016-12-01

    The present paper focuses on the measurement of health literacy (HL), which is an important determinant of health and health behaviours. HL starts to develop in childhood and adolescence; hence, there is a need for instruments to monitor HL among younger age groups. These instruments are still rare. The aim of the project reported here was, therefore, to develop a brief, multidimensional, theory-based instrument to measure subjective HL among school-aged children. The development of the instrument covered four phases: item generation based on a conceptual framework; a pilot study ( n = 405); test-retest ( n = 117); and construction of the instrument ( n = 3853). All the samples were taken from Finnish 7th and 9th graders. Initially, 65 items were generated, of which 32 items were selected for the pilot study. After item reduction, the instrument contained 16 items. The test-retest phase produced estimates of stability. In the final phase a 10-item instrument was constructed, referred to as Health Literacy for School-Aged Children (HLSAC). The instrument exhibited a high Cronbach alpha (0.93), and included two items from each of the five predetermined theoretical components (theoretical knowledge, practical knowledge, critical thinking, self-awareness, citizenship). The iterative and validity-driven development process made it possible to construct a brief multidimensional HLSAC instrument. Such instruments are suitable for large-scale studies, and for use with children and adolescents. Validation will require further testing for use in other countries.

  17. Instrumentation for motor-current signature analysis using synchronous sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castleberry, K.N.

    1996-07-01

    Personnel in the Instrumentation and Controls Division at Oak Ridge National Laboratory, in association with the United States Enrichment Corporation, the U.S. Navy, and various Department of Energy sponsors, have been involved in the development and application of motor-current signature analysis for several years. In that time, innovation in the field has resulted in major improvements in signal processing, analysis, and system performance and capabilities. Recent work has concentrated on industrial implementation of one of the most promising new techniques. This report describes the developed method and the instrumentation package that is being used to investigate and develop potential applications.

  18. The quality of instruments to assess the process of shared decision making: A systematic review.

    PubMed

    Gärtner, Fania R; Bomhof-Roordink, Hanna; Smith, Ian P; Scholl, Isabelle; Stiggelbout, Anne M; Pieterse, Arwen H

    2018-01-01

    To inventory instruments assessing the process of shared decision making and appraise their measurement quality, taking into account the methodological quality of their validation studies. In a systematic review we searched seven databases (PubMed, Embase, Emcare, Cochrane, PsycINFO, Web of Science, Academic Search Premier) for studies investigating instruments measuring the process of shared decision making. Per identified instrument, we assessed the level of evidence separately for 10 measurement properties following a three-step procedure: 1) appraisal of the methodological quality using the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist, 2) appraisal of the psychometric quality of the measurement property using three possible quality scores, 3) best-evidence synthesis based on the number of studies, their methodological and psychometrical quality, and the direction and consistency of the results. The study protocol was registered at PROSPERO: CRD42015023397. We included 51 articles describing the development and/or evaluation of 40 shared decision-making process instruments: 16 patient questionnaires, 4 provider questionnaires, 18 coding schemes and 2 instruments measuring multiple perspectives. There is an overall lack of evidence for their measurement quality, either because validation is missing or methods are poor. The best-evidence synthesis indicated positive results for a major part of instruments for content validity (50%) and structural validity (53%) if these were evaluated, but negative results for a major part of instruments when inter-rater reliability (47%) and hypotheses testing (59%) were evaluated. Due to the lack of evidence on measurement quality, the choice for the most appropriate instrument can best be based on the instrument's content and characteristics such as the perspective that they assess. We recommend refinement and validation of existing instruments, and the use of COSMIN-guidelines to help guarantee high-quality evaluations.

  19. Promoting the hydrostatic conceptual change test (HCCT) with four-tier diagnostic test item

    NASA Astrophysics Data System (ADS)

    Purwanto, M. G.; Nurliani, R.; Kaniawati, I.; Samsudin, A.

    2018-05-01

    Hydrostatic Conceptual Change Test (HCCT) is a diagnostic test instrument to identify students’ conception on Hydrostatic field. It is very important to support the learning process in the classroom. Based on that point of view, the researcher decided to develop HCCT instrument test into four-tier test diagnostic items. The resolve of this research is planned as the first step of four-tier test-formatted HCCT development as one of investigative test instrument on Hydrostatic. The research method used the 4D model which has four comprehensive steps: 1) defining, 2) designing, 3) developing and 4) disseminating. The instrument developed has been tried to 30 students in one of senior high schools. The data showed that four-tier- test-formatted HCCT is able to identify student’s conception level of Hydrostatic. In conclusion, the development of four-tier test-formatted HCCT is one of potential diagnostic test instrument that able to classify the category of students who misconception, no understanding, understanding, partial understanding and no codeable about concept of Hydrostatic.

  20. Policy instruments for pollution control in developing countries.

    PubMed

    Eskeland, G S; Jimenez, E

    1992-07-01

    Economic development in developing countries must be accomplished in a manner that does not harm the environment with pollution. Pollution harms human health and productivity. Thus appropriate strategies must be developed that promote growth, reduce poverty, and protect the environment. A review of the current literature is performed with attention paid to cost-effective interventions i.e., comparisons of regulatory and fiscal instruments that can reduce pollution. Both direct instruments (like effluent charges, tradable permits, deposit refund systems, emission regulations and regulatory agency funding for purification, cleanup, waste disposal, and enforcement) and indirect instruments (like input/output taxes and subsidies, substitution subsidies, abatement inputs, regulation of equipment and processes, and development of clean technologies) are examined. Examples are used to show how indirect instruments can be successful when monitoring and enforcement is too costly. A careful examination of distributive concerns illustrate how the effect on the poor may need particular consideration and how groups with vested interests can help evaluate the probable success of such interventions.

  1. Development Instrument’s Learning of Physics Through Scientific Inquiry Model Based Batak Culture to Improve Science Process Skill and Student’s Curiosity

    NASA Astrophysics Data System (ADS)

    Nasution, Derlina; Syahreni Harahap, Putri; Harahap, Marabangun

    2018-03-01

    This research aims to: (1) developed a instrument’s learning (lesson plan, worksheet, student’s book, teacher’s guide book, and instrument test) of physics learning through scientific inquiry learning model based Batak culture to achieve skills improvement process of science students and the students’ curiosity; (2) describe the quality of the result of develop instrument’s learning in high school using scientific inquiry learning model based Batak culture (lesson plan, worksheet, student’s book, teacher’s guide book, and instrument test) to achieve the science process skill improvement of students and the student curiosity. This research is research development. This research developed a instrument’s learning of physics by using a development model that is adapted from the development model Thiagarajan, Semmel, and Semmel. The stages are traversed until retrieved a valid physics instrument’s learning, practical, and effective includes :(1) definition phase, (2) the planning phase, and (3) stages of development. Test performed include expert test/validation testing experts, small groups, and test classes is limited. Test classes are limited to do in SMAN 1 Padang Bolak alternating on a class X MIA. This research resulted in: 1) the learning of physics static fluid material specially for high school grade 10th consisted of (lesson plan, worksheet, student’s book, teacher’s guide book, and instrument test) and quality worthy of use in the learning process; 2) each component of the instrument’s learning meet the criteria have valid learning, practical, and effective way to reach the science process skill improvement and curiosity in students.

  2. A neuropsychological instrument measuring age-related cerebral decline in older drivers: development, reliability, and validity of MedDrive

    PubMed Central

    Vaucher, Paul; Cardoso, Isabel; Veldstra, Janet L.; Herzig, Daniela; Herzog, Michael; Mangin, Patrice; Favrat, Bernard

    2014-01-01

    When facing age-related cerebral decline, older adults are unequally affected by cognitive impairment without us knowing why. To explore underlying mechanisms and find possible solutions to maintain life-space mobility, there is a need for a standardized behavioral test that relates to behaviors in natural environments. The aim of the project described in this paper was therefore to provide a free, reliable, transparent, computer-based instrument capable of detecting age-related changes on visual processing and cortical functions for the purposes of research into human behavior in computational transportation science. After obtaining content validity, exploring psychometric properties of the developed tasks, we derived (Study 1) the scoring method for measuring cerebral decline on 106 older drivers aged ≥70 years attending a driving refresher course organized by the Swiss Automobile Association to test the instrument's validity against on-road driving performance (106 older drivers). We then validated the derived method on a new sample of 182 drivers (Study 2). We then measured the instrument's reliability having 17 healthy, young volunteers repeat all tests included in the instrument five times (Study 3) and explored the instrument's psychophysical underlying functions on 47 older drivers (Study 4). Finally, we tested the instrument's responsiveness to alcohol and effects on performance on a driving simulator in a randomized, double-blinded, placebo, crossover, dose-response, validation trial including 20 healthy, young volunteers (Study 5). The developed instrument revealed good psychometric properties related to processing speed. It was reliable (ICC = 0.853) and showed reasonable association to driving performance (R2 = 0.053), and responded to blood alcohol concentrations of 0.5 g/L (p = 0.008). Our results suggest that MedDrive is capable of detecting age-related changes that affect processing speed. These changes nevertheless do not necessarily affect driving behavior. PMID:25346674

  3. Students' Socioscientific Reasoning and Decision-making on Energy-related Issues—Development of a measurement instrument

    NASA Astrophysics Data System (ADS)

    Sakschewski, Mark; Eggert, Sabina; Schneider, Susanne; Bögeholz, Susanne

    2014-09-01

    The concept of energy is one key component of science education curricula worldwide. While it is still being taught in many science classrooms from a mainly conceptual knowledge perspective, the need to frame the concept of energy as a socioscientific issue and implement it in the context of citizenship education and education for sustainable development, is getting more and more explicit. As we will be faced with limited fossil fuels and the consequences of global climate change in the future, students have to be supported in becoming literate citizens who are able to reach informed energy-related decisions. In this article, we focus on students' reasoning and decision-making processes about socioscientific energy-related issues. In more detail, we developed a paper-and-pencil measurement instrument to assess secondary school students' competencies in this domain. The functioning of the measurement instrument was analysed with a sample of 850 students from grades 6, 8, 10 and 12 using item response theory. Findings show that the measurement instrument functions in terms of reliability and validity. Concerning student ability, elaborate reasoning and decision-making was characterised by the use of trade-offs and the ability to weigh arguments and to reflect on the structure of reasoning and decision-making processes. The developed measurement instrument provides a complement for existing test instruments on conceptual knowledge about the concept of energy. It aims to contribute to a change in teaching about energy, especially in physics education in the sense of education for sustainable development.

  4. Evaluating the Quality of Learning Environments and Teaching Practice in Special Schools

    ERIC Educational Resources Information Center

    Hedegaard-Soerensen, Lotte; Tetler, Susan

    2016-01-01

    This article reports on findings of a study which objective is the development of an instrument for systematic evaluation and improvement of the quality of teaching in special schools. The article describes the research process which led to the construction of the instrument as well as the way teachers can use the instrument to improve the quality…

  5. Designing Spatial Visualisation Tasks for Middle School Students with a 3D Modelling Software: An Instrumental Approach

    ERIC Educational Resources Information Center

    Turgut, Melih; Uygan, Candas

    2015-01-01

    In this work, certain task designs to enhance middle school students' spatial visualisation ability, in the context of an instrumental approach, have been developed. 3D modelling software, SketchUp®, was used. In the design process, software tools were focused on and, thereafter, the aim was to interpret the instrumental genesis and spatial…

  6. Development of a surface topography instrument for automotive textured steel plate

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Wang, Shenghuai; Chen, Yurong; Xie, Tiebang

    2010-08-01

    The surface topography of automotive steel plate is decisive to its stamping, painting and image clarity performances. For measuring this kind of surface topography, an instrument has been developed based on the principle of vertical scanning white light microscopy interference principle. The microscopy interference system of this instrument is designed based on the structure of Linnik interference microscopy. The 1D worktable of Z direction is designed and introduced in details. The work principle of this instrument is analyzed. In measuring process, the interference microscopy is derived as a whole and the measured surface is scanned in vertical direction. The measurement accuracy and validity is verified by templates. Surface topography of textured steel plate is also measured by this instrument.

  7. Content validity--establishing and reporting the evidence in newly developed patient-reported outcomes (PRO) instruments for medical product evaluation: ISPOR PRO good research practices task force report: part 1--eliciting concepts for a new PRO instrument.

    PubMed

    Patrick, Donald L; Burke, Laurie B; Gwaltney, Chad J; Leidy, Nancy Kline; Martin, Mona L; Molsen, Elizabeth; Ring, Lena

    2011-12-01

    The importance of content validity in developing patient reported outcomes (PRO) instruments is stressed by both the US Food and Drug Administration and the European Medicines Agency. Content validity is the extent to which an instrument measures the important aspects of concepts that developers or users purport it to assess. A PRO instrument measures the concepts most significant and relevant to a patient's condition and its treatment. For PRO instruments, items and domains as reflected in the scores of an instrument should be important to the target population and comprehensive with respect to patient concerns. Documentation of target population input in item generation, as well as evaluation of patient understanding through cognitive interviewing, can provide the evidence for content validity. Developing content for, and assessing respondent understanding of, newly developed PRO instruments for medical product evaluation will be discussed in this two-part ISPOR PRO Good Research Practices Task Force Report. Topics include the methods for generating items, documenting item development, coding of qualitative data from item generation, cognitive interviewing, and tracking item development through the various stages of research and preparing this tracking for submission to regulatory agencies. Part 1 covers elicitation of key concepts using qualitative focus groups and/or interviews to inform content and structure of a new PRO instrument. Part 2 covers the instrument development process, the assessment of patient understanding of the draft instrument using cognitive interviews and steps for instrument revision. The two parts are meant to be read together. They are intended to offer suggestions for good practices in planning, executing, and documenting qualitative studies that are used to support the content validity of PRO instruments to be used in medical product evaluation. Copyright © 2011 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  8. The Process of Developing a Multi-Cell KEMS Instrument

    NASA Technical Reports Server (NTRS)

    Copland, E. H.; Auping, J. V.; Jacobson, N. S.

    2012-01-01

    Multi-cell KEMS offers many advantages over single cell instruments in regard to in-situ temperature calibration and studies on high temperature alloys and oxides of interest to NASA. The instrument at NASA Glenn is a 90 deg magnetic sector instrument originally designed for single cell operation. The conversion of this instrument to a multi-cell instrument with restricted collimation is discussed. For restricted collimation, the 'field aperture' is in the copper plate separating the Knudsen Cell region and the ionizer and the 'source aperture' is adjacent to the ionizer box. A computer controlled x-y table allows positioning of one of the three cells into the sampling region. Heating is accomplished via a Ta sheet element and temperature is measured via an automatic pyrometer from the bottom of the cells. The computer control and data system have been custom developed for this instrument and are discussed. Future improvements are also discussed.

  9. Comparative Analysis of the Measurement of Total Instructional Alignment

    ERIC Educational Resources Information Center

    Kick, Laura C.

    2013-01-01

    In 2007, Lisa Carter created the Total Instructional Alignment system--a process that aligns standards, curriculum, assessment, and instruction. Employed in several hundred school systems, the TIA process is a successful professional development program. The researcher developed an instrument to measure the success of the TIA process with the…

  10. Lessons Learned From Developing Three Generations of Remote Sensing Science Data Processing Systems

    NASA Technical Reports Server (NTRS)

    Tilmes, Curt; Fleig, Albert J.

    2005-01-01

    The Biospheric Information Systems Branch at NASA s Goddard Space Flight Center has developed three generations of Science Investigator-led Processing Systems for use with various remote sensing instruments. The first system is used for data from the MODIS instruments flown on NASA s Earth Observing Systems @OS) Terra and Aqua Spacecraft launched in 1999 and 2002 respectively. The second generation is for the Ozone Measuring Instrument flying on the EOS Aura spacecraft launched in 2004. We are now developing a third generation of the system for evaluation science data processing for the Ozone Mapping and Profiler Suite (OMPS) to be flown by the NPOESS Preparatory Project (NPP) in 2006. The initial system was based on large scale proprietary hardware, operating and database systems. The current OMI system and the OMPS system being developed are based on commodity hardware, the LINUX Operating System and on PostgreSQL, an Open Source RDBMS. The new system distributes its data archive across multiple server hosts and processes jobs on multiple processor boxes. We have created several instances of this system, including one for operational processing, one for testing and reprocessing and one for applications development and scientific analysis. Prior to receiving the first data from OMI we applied the system to reprocessing information from the Solar Backscatter Ultraviolet (SBUV) and Total Ozone Mapping Spectrometer (TOMS) instruments flown from 1978 until now. The system was able to process 25 years (108,000 orbits) of data and produce 800,000 files (400 GiB) of level 2 and level 3 products in less than a week. We will describe the lessons we have learned and tradeoffs between system design, hardware, operating systems, operational staffing, user support and operational procedures. During each generational phase, the system has become more generic and reusable. While the system is not currently shrink wrapped we believe it is to the point where it could be readily adopted, with substantial cost savings, for other similar tasks.

  11. Pancreatitis Quality of Life Instrument: Development of a new instrument

    PubMed Central

    Bova, Carol; Barton, Bruce; Hartigan, Celia

    2014-01-01

    Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors). Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use. PMID:26770703

  12. Design and development of a cross-cultural disposition inventory

    NASA Astrophysics Data System (ADS)

    Davies, Randall; Zaugg, Holt; Tateishi, Isaku

    2015-01-01

    Advances in technology have increased the likelihood that engineers will have to work in a global, culturally diverse setting. Many schools of engineering are currently revising their curricula to help students to develop cultural competence. However, our ability to measure cultural dispositions can be a challenge. The purpose of this project was to develop and test an instrument that measures the various aspects of cultural disposition. The results of the validation process verified that the hypothesised model adequately represented the data. The refined instrument produced a four-factor model for the overall construct. The validation process for the instrument verified the existence of specific subcomponents that form the overall cultural disposition construct. There also seems to be a hierarchical relationship within the subcomponents of cultural disposition. Additional research is needed to explore which aspects of cultural disposition affect an individual's ability to work effectively in a culturally diverse engineering team.

  13. Study on virtual instrument developing system based on intelligent virtual control

    NASA Astrophysics Data System (ADS)

    Tang, Baoping; Cheng, Fabin; Qin, Shuren

    2005-01-01

    The paper introduces a non-programming developing system of a virtual instument (VI), i.e., a virtual measurement instrument developing system (VMIDS) based on intelligent virtual control (IVC). The background of the IVC-based VMIDS is described briefly, and the hierarchical message bus (HMB)-based software architecture of VMIDS is discussed in detail. The three parts and functions of VMIDS are introduced, and the process of non-programming developing VI is further described.

  14. Instrumentation complex for Langley Research Center's National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Russell, C. H.; Bryant, C. S.

    1977-01-01

    The instrumentation discussed in the present paper was developed to ensure reliable operation for a 2.5-meter cryogenic high-Reynolds-number fan-driven transonic wind tunnel. It will incorporate four CPU's and associated analog and digital input/output equipment, necessary for acquiring research data, controlling the tunnel parameters, and monitoring the process conditions. Connected in a multipoint distributed network, the CPU's will support data base management and processing; research measurement data acquisition and display; process monitoring; and communication control. The design will allow essential processes to continue, in the case of major hardware failures, by switching input/output equipment to alternate CPU's and by eliminating nonessential functions. It will also permit software modularization by CPU activity and thereby reduce complexity and development time.

  15. Adaptation Strategies to Climate Change and the Role of Planning Instruments - The Example of the Dresden Region (Saxony/Germany)

    NASA Astrophysics Data System (ADS)

    Albrecht, J.; Juta, K.; Nobis, A.

    2009-04-01

    In the past, identifying anthropogenic influences on climate change, scenario analyses and issues of climate change mitigation were predominant approaches in climate change research (IPCC 2007). Currently, for instance in Germany, climate impact research on regional level comes to the forefront of research and policy making. Climate change has become an important topic on the agenda of politicians, administration and planning. In order to counteract the (unavoidable) climate change and its impacts it is necessary to develop adaptation strategies. At present, such strategies and guidelines are formulated on international, supranational and national level. The initial point was the United Nations Framework Convention on Climate Change in 1992 where the contracting states obligated themselves to develop national (and regional) programmes for adaptation. In 2007 the European Commission published its Green Paper called Adaptation to Climate Change in Europe. The paper states that adaptation efforts have to be intensified at different (spatial) levels (local, regional, national, and so forth). Furthermore, coordinating these efforts is of high importance. With the recent agreement on the German Adaptation Strategy to Climate Change (DAS 2008) in December 2008, federal government tries to accomplish this task. The German strategy mainly focuses on two elements: decreasing vulnerability and increasing adaptability. While the above mentioned strategies have presented information and policies concerning climate change and adaptation on international, supranational and national level, such documents dońt yet exist on regional level. However, because of their close link to the local level the regions are of high importance for adaptation strategies. Therefore, the Leibniz-Institute of Ecological and Regional Development developed a transdisciplinary project to formulate and implement the so-called Integrated Regional Climate Adaptation Programme (IRCAP) for the Model Region of Dresden (project REGKLAM). The REGKLAM-project is based on regionalised scenarios of climate change and includes measures of climate change adaptation to change for instance, urban form, infrastructure assets (e.g., reservoirs) and land use. Various institutions from politics, administration, economy, and research as well as civil society are involved in the project (the city of Dresden, several ministries and authorities of Saxony, the Dresden Chamber of Industry and Commerce and the University of Dresden). The IRCAP is planned to be an informal, cross-sectoral instrument of adaptation to climate change. As a regional programme, the IRCAP is addressed to decision-makers of the region of Dresden (defined, for instance, as planning region). Its function is to complement and coordinate existing instruments and measures. These instruments also include instruments of environmental and spatial planning on the regional level. Spatial and environmental planning can rely on a wide range of formal and informal instruments on different spatial, administrative, and sectoral levels, e.g. land use and landscape plans. Our contribution to the EGU conference aims to clear the role and relevance of the existing formal and informal planning instruments in the region of Dresden for the process of developing the IRCAP. Firstly, a survey is conducted for the purpose of identifying all relevant planning instruments. The identification process is based on specific criteria, for example: reference to the region, contents relating to the topic of climate change respectively climate adaptation. Secondly, the presentation argues for a selection of those planning instruments which seem to be most relevant for the process of developing an IRCAP. This selection process is based on specific criteria which include, for instance, complexity of expected effects, reference to regional and sectoral vulnerability, opportunity for future change of the existing planning instruments (e.g., current process of updating), interests of project partners and stakeholders. Thirdly, as a result, an overview of relevant planning instruments in the region of Dresden is shown, including their current status and statements about their relevance for the topic of climate adaptation strategies. Finally it is derived that this procedure provides a basis for the following possibilities: Adapting existing planning instruments, integrate contents of existing planning instruments in the IRCAP process, or develop and define new strategies or measures on the way to an IRCAP.

  16. Chromosome Analysis

    NASA Technical Reports Server (NTRS)

    1998-01-01

    Perceptive Scientific Instruments, Inc., provides the foundation for the Powergene line of chromosome analysis and molecular genetic instrumentation. This product employs image processing technology from NASA's Jet Propulsion Laboratory and image enhancement techniques from Johnson Space Center. Originally developed to send pictures back to earth from space probes, digital imaging techniques have been developed and refined for use in a variety of medical applications, including diagnosis of disease.

  17. Design and Construction of a Portable Oculometer for Use in Transportation Oriented Human Factors Studies

    DOT National Transportation Integrated Search

    1971-08-01

    THE REPORT DESCRIBES DEVELOPMENT OF AN INSTRUMENT DESIGNED TO ACQUIRE AND PROCESS INFORMATION ABOUT HUMAN VISUAL PERFORMANCE. THE INSTRUMENT HAS THE FOLLOWING FEATURES: IT CAN BE OPERATED IN A VARIETY OF TRANSPORTATION ENVIRONMENTS INCLUDING SIMULATO...

  18. The Development and Validation of an Instrument to Measure Preservice Teachers' Self-Efficacy in Regard to The Teaching of Science as Inquiry

    NASA Astrophysics Data System (ADS)

    Dira Smolleck, Lori; Zembal-Saul, Carla; Yoder, Edgar P.

    2006-06-01

    The purpose of this study was to develop, validate, and establish the reliability of an instrument that measures preservice teachers' self-efficacy in regard to the teaching of science as inquiry. The instrument, Teaching Science as Inquiry (TSI), is based upon the work of Bandura (1977, 1981, 1982, 1986, 1989, 1995, 1997), Riggs (1988), and Enochs and Riggs (1990). Self-efficacy in regard to the teaching of science as inquiry was measured through the use of a 69-item Likert-type scale instrument designed by the author of the study. Based on the standardized development processes used and the associated evidence, the TSI appears to be a content and construct valid instrument with high internal reliability for use with preservice elementary teachers to assess self-efficacy beliefs in regard to the teaching of science as inquiry.

  19. The Development and Validation of an Instrument to Measure Preservice Teachers' Self-Efficacy in Regard to The Teaching of Science as Inquiry

    NASA Astrophysics Data System (ADS)

    Smolleck, Lori Dira; Zembal-Saul, Carla; Yoder, Edgar P.

    2006-06-01

    The purpose of this study was to develop, validate, and establish the reliability of an instrument that measures preservice teachers' self-efficacy in regard to the teaching of science as inquiry. The instrument, Teaching Science as Inquiry (TSI), is based upon the work of Bandura (1977, 1981, 1982, 1986, 1989, 1995, 1997), Riggs (1988), and Enochs and Riggs (1990). Self-efficacy in regard to the teaching of science as inquiry was measured through the use of a 69-item Likert-type scale instrument designed by the author of the study. Based on the standardized development processes used and the associated evidence, the TSI appears to be a content and construct valid instrument with high internal reliability for use with preservice elementary teachers to assess self-efficacy beliefs in regard to the teaching of science as inquiry.

  20. Experimental Methods Using Photogrammetric Techniques for Parachute Canopy Shape Measurements

    NASA Technical Reports Server (NTRS)

    Jones, Thomas W.; Downey, James M.; Lunsford, Charles B.; Desabrais, Kenneth J.; Noetscher, Gregory

    2007-01-01

    NASA Langley Research Center in partnership with the U.S. Army Natick Soldier Center has collaborated on the development of a payload instrumentation package to record the physical parameters observed during parachute air drop tests. The instrumentation package records a variety of parameters including canopy shape, suspension line loads, payload 3-axis acceleration, and payload velocity. This report discusses the instrumentation design and development process, as well as the photogrammetric measurement technique used to provide shape measurements. The scaled model tests were conducted in the NASA Glenn Plum Brook Space Propulsion Facility, OH.

  1. Atomic Force Microscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Day, R.D.; Russell, P.E.

    The Atomic Force Microscope (AFM) is a recently developed instrument that has achieved atomic resolution imaging of both conducting and non- conducting surfaces. Because the AFM is in the early stages of development, and because of the difficulty of building the instrument, it is currently in use in fewer than ten laboratories worldwide. It promises to be a valuable tool for obtaining information about engineering surfaces and aiding the .study of precision fabrication processes. This paper gives an overview of AFM technology and presents plans to build an instrument designed to look at engineering surfaces.

  2. The cross-cultural equivalence of participation instruments: a systematic review.

    PubMed

    Stevelink, S A M; van Brakel, W H

    2013-07-01

    Concepts such as health-related quality of life, disability and participation may differ across cultures. Consequently, when assessing such a concept using a measure developed elsewhere, it is important to test its cultural equivalence. Previous research suggested a lack of cultural equivalence testing in several areas of measurement. This paper reviews the process of cross-cultural equivalence testing of instruments to measure participation in society. An existing cultural equivalence framework was adapted and used to assess participation instruments on five categories of equivalence: conceptual, item, semantic, measurement and operational equivalence. For each category, several aspects were rated, resulting in an overall category rating of 'minimal/none', 'partial' or 'extensive'. The best possible overall study rating was five 'extensive' ratings. Articles were included if the instruments focussed explicitly on measuring 'participation' and were theoretically grounded in the ICIDH(-2) or ICF. Cross-validation articles were only included if it concerned an adaptation of an instrument developed in a high or middle-income country to a low-income country or vice versa. Eight cross-cultural validation studies were included in which five participation instruments were tested (Impact on Participation and Autonomy, London Handicap Scale, Perceived Impact and Problem Profile, Craig Handicap Assessment Reporting Technique, Participation Scale). Of these eight studies, only three received at least two 'extensive' ratings for the different categories of equivalence. The majority of the cultural equivalence ratings given were 'partial' and 'minimal/none'. The majority of the 'none/minimal' ratings were given for item and measurement equivalence. The cross-cultural equivalence testing of the participation instruments included leaves much to be desired. A detailed checklist is proposed for designing a cross-validation study. Once a study has been conducted, the checklist can be used to ensure comprehensive reporting of the validation (equivalence) testing process and its results. • Participation instruments are often used in a different cultural setting than initial developed for. • The conceptualization of participation may vary across cultures. Therefore, cultural equivalence – the extent to which an instrument is equally suitable for use in two or more cultures – is an important concept to address. • This review showed that the process of cultural equivalence testing of the included participation instruments was often addressed insufficiently. • Clinicians should be aware that application of participations instruments in a different culture than initially developed for needs prior testing of cultural validity in the next context.

  3. A Compact Airborne High Spectral Resolution Lidar for Observations of Aerosol and Cloud Optical Properties

    NASA Technical Reports Server (NTRS)

    Hostetler, Chris A.; Hair, John W.; Cook, Anthony L.

    2002-01-01

    We are in the process of developing a nadir-viewing, aircraft-based high spectral resolution lidar (HSRL) at NASA Langley Research Center. The system is designed to measure backscatter and extinction of aerosols and tenuous clouds. The primary uses of the instrument will be to validate spaceborne aerosol and cloud observations, carry out regional process studies, and assess the predictions of chemical transport models. In this paper, we provide an overview of the instrument design and present the results of simulations showing the instrument's capability to accurately measure extinction and extinction-to-backscatter ratio.

  4. Small Fluxgate Magnetometers: Development and Future Trends in Spain

    PubMed Central

    Ciudad, David; Díaz-Michelena, Marina; Pérez, Lucas; Aroca, Claudio

    2010-01-01

    In this paper, we give an overview of the research on fluxgate magnetometers carried out in Spain. In particular we focus in the development of the planar-type instruments. We summarize the fabrication processes and signal processing developments as well as their use in complex systems and space. PMID:22294904

  5. Small fluxgate magnetometers: development and future trends in Spain.

    PubMed

    Ciudad, David; Díaz-Michelena, Marina; Pérez, Lucas; Aroca, Claudio

    2010-01-01

    In this paper, we give an overview of the research on fluxgate magnetometers carried out in Spain. In particular we focus in the development of the planar-type instruments. We summarize the fabrication processes and signal processing developments as well as their use in complex systems and space.

  6. Developing and testing instruments for improving cooperation and patient's participation in mental health care.

    PubMed

    Latvala, E; Saranto, K; Pekkala, E

    2004-10-01

    The main purpose of the project was to develop computerized instruments that could be used by nurses and patients to assess their cooperation and mutual contributions to care. This paper presents a part of the project: the reliability and validity testing phase of a process of instrument development. To test the validity and reliability of the instruments, data were collected with questionnaires from nurses (n = 146) and patients (n = 286). The validity evaluated as construct validity and the reliability evaluated as internal consistency of the instruments were quite good. Construct validity was tested by factor analysis, and internal consistency was tested by Cronbach's alpha coefficient, which varied from 0.69 to 0.79. The instruments, which consisted of a software application that can be operated in a www environment, were meant to be used as tools in the psychiatric nursing context for assessing the cooperation between the nurses and patients and the patient's participation in his/her care. Furthermore, the computer programme can be used as a tool for developing and assessing the patient orientation in nursing.

  7. Large Instrument Development for Radio Astronomy

    NASA Astrophysics Data System (ADS)

    Fisher, J. Richard; Warnick, Karl F.; Jeffs, Brian D.; Norrod, Roger D.; Lockman, Felix J.; Cordes, James M.; Giovanelli, Riccardo

    2009-03-01

    This white paper offers cautionary observations about the planning and development of new, large radio astronomy instruments. Complexity is a strong cost driver so every effort should be made to assign differing science requirements to different instruments and probably different sites. The appeal of shared resources is generally not realized in practice and can often be counterproductive. Instrument optimization is much more difficult with longer lists of requirements, and the development process is longer and less efficient. More complex instruments are necessarily further behind the technology state of the art because of longer development times. Including technology R&D in the construction phase of projects is a growing trend that leads to higher risks, cost overruns, schedule delays, and project de-scoping. There are no technology breakthroughs just over the horizon that will suddenly bring down the cost of collecting area. Advances come largely through careful attention to detail in the adoption of new technology provided by industry and the commercial market. Radio astronomy instrumentation has a very bright future, but a vigorous long-term R&D program not tied directly to specific projects needs to be restored, fostered, and preserved.

  8. Developing energy and momentum conceptual survey (EMCS) with four-tier diagnostic test items

    NASA Astrophysics Data System (ADS)

    Afif, Nur Faadhilah; Nugraha, Muhammad Gina; Samsudin, Achmad

    2017-05-01

    Students' conceptions of work and energy are important to support the learning process in the classroom. For that reason, a diagnostic test instrument is needed to diagnose students' conception of work and energy. As a result, the researcher decided to develop Energy and Momentum Conceptual Survey (EMCS) instrument test into four-tier test diagnostic items. The purpose of this research is organized as the first step of four-tier test-formatted EMCS development as one of diagnostic test instruments on work and Energy. The research method used the 4D model (Defining, Designing, Developing and Disseminating). The instrument developed has been tested to 39 students in one of Senior High Schools. The resulting research showed that four-tier test-formatted EMCS is able to diagnose students' conception level of work and energy concept. It can be concluded that the development of four-tier test-formatted EMCS is one of potential diagnostic test instruments that able to obtain the category of students who understand concepts, misconceptions and do not understand about Work and Energy concept at all.

  9. Normative Databases for Imaging Instrumentation.

    PubMed

    Realini, Tony; Zangwill, Linda M; Flanagan, John G; Garway-Heath, David; Patella, Vincent M; Johnson, Chris A; Artes, Paul H; Gaddie, Ian B; Fingeret, Murray

    2015-08-01

    To describe the process by which imaging devices undergo reference database development and regulatory clearance. The limitations and potential improvements of reference (normative) data sets for ophthalmic imaging devices will be discussed. A symposium was held in July 2013 in which a series of speakers discussed issues related to the development of reference databases for imaging devices. Automated imaging has become widely accepted and used in glaucoma management. The ability of such instruments to discriminate healthy from glaucomatous optic nerves, and to detect glaucomatous progression over time is limited by the quality of reference databases associated with the available commercial devices. In the absence of standardized rules governing the development of reference databases, each manufacturer's database differs in size, eligibility criteria, and ethnic make-up, among other key features. The process for development of imaging reference databases may be improved by standardizing eligibility requirements and data collection protocols. Such standardization may also improve the degree to which results may be compared between commercial instruments.

  10. Normative Databases for Imaging Instrumentation

    PubMed Central

    Realini, Tony; Zangwill, Linda; Flanagan, John; Garway-Heath, David; Patella, Vincent Michael; Johnson, Chris; Artes, Paul; Ben Gaddie, I.; Fingeret, Murray

    2015-01-01

    Purpose To describe the process by which imaging devices undergo reference database development and regulatory clearance. The limitations and potential improvements of reference (normative) data sets for ophthalmic imaging devices will be discussed. Methods A symposium was held in July 2013 in which a series of speakers discussed issues related to the development of reference databases for imaging devices. Results Automated imaging has become widely accepted and used in glaucoma management. The ability of such instruments to discriminate healthy from glaucomatous optic nerves, and to detect glaucomatous progression over time is limited by the quality of reference databases associated with the available commercial devices. In the absence of standardized rules governing the development of reference databases, each manufacturer’s database differs in size, eligibility criteria, and ethnic make-up, among other key features. Conclusions The process for development of imaging reference databases may be improved by standardizing eligibility requirements and data collection protocols. Such standardization may also improve the degree to which results may be compared between commercial instruments. PMID:25265003

  11. Optimizing Catalysts for Solar Fuel Production: Spectroscopic Characterization of the Key Reaction Intermediates

    DTIC Science & Technology

    2013-04-01

    which freezes ions into well defined structures and coats them with an inert layer of weakly bound adducts. These cold aggregates were then...evaporation of the cryogenic solvent. Instrument development. Cryogenic ion processing. Cold ion spectroscopy. Trapped reaction intermediates U U U...spectrometer. The key advance incorporated into this instrument is the introduction of a cryogenic (10K) ion processing stage, where ions can be frozen

  12. The Divergent Thinking of Basic Skills of Sciences Process Skills of Life Aspects on Natural Sciences Subject in Indonesian Elementary School Students

    ERIC Educational Resources Information Center

    Subali, Bambang; Paidi; Mariyam, Siti

    2016-01-01

    This research aims at measuring the divergent thinking of basic skills of science process skills (SPS) of life aspects in Natural Sciences subjects on Elementary School. The test instruments used in this research have been standardized through the development of instruments. In this case, the tests were tried out to 3070 students. The results of…

  13. Utilization of Space Station Freedom for technology research

    NASA Technical Reports Server (NTRS)

    Avery, Don E.

    1992-01-01

    Space Station Freedom presents a unique opportunity for technology developers to conduct research in the space environment. Research can be conducted in the pressurized volume of the Space Station's laboratories or attached to the Space Station truss in the vacuum of space. Technology developers, represented by the Office of Aeronautics and Space Technology (OAST), will have 12 percent of the available Space Station resources (volume, power, data, crew, etc.) to use for their research. Most technologies can benefit from research on Space Station Freedom and all these technologies are represented in the OAST proposed traffic model. This traffic model consists of experiments that have been proposed by technology developers but not necessarily selected for flight. Experiments to be flown in space will be selected through an Announcement of Opportunity (A.O.) process. The A.O. is expected to be released in August, 1992. Experiments will generally fall into one of the 3 following categories: (1) Individual technology experiments; (2) Instrumented Space Station; and (3) Guest investigator program. The individual technology experiments are those that do not instrument the Space Station nor directly relate to the development of technologies for evolution of Space Station or development of advanced space platforms. The Instrumented Space Station category is similar to the Orbiter Experiments Program and allows the technology developer to instrument subsystems on the Station or develop instrumentation packages that measure products or processes of the Space Station for the advancement of space platform technologies. The guest investigator program allows the user to request data from Space Station or other experiments for independent research. When developing an experiment, a developer should consider all the resources and infrastructure that Space Station Freedom can provide and take advantage of these to the maximum extent possible. Things like environment, accommodations, carriers, and integration should all be taken into account. In developing experiments at Langley Research Center, an iterative approach is proving useful. This approach uses Space Station utilization and subsystem experts to advise and critique experiment designs to take advantage of everything the Space Station has to offer. Also, solid object modeling and animation computer tools are used to fully visualize the experiment and its processes. This process is very useful for attached payloads and allows problems to be detected early in the experiment design phase.

  14. Application of High Speed Digital Image Correlation in Rocket Engine Hot Fire Testing

    NASA Technical Reports Server (NTRS)

    Gradl, Paul R.; Schmidt, Tim

    2016-01-01

    Hot fire testing of rocket engine components and rocket engine systems is a critical aspect of the development process to understand performance, reliability and system interactions. Ground testing provides the opportunity for highly instrumented development testing to validate analytical model predictions and determine necessary design changes and process improvements. To properly obtain discrete measurements for model validation, instrumentation must survive in the highly dynamic and extreme temperature application of hot fire testing. Digital Image Correlation has been investigated and being evaluated as a technique to augment traditional instrumentation during component and engine testing providing further data for additional performance improvements and cost savings. The feasibility of digital image correlation techniques were demonstrated in subscale and full scale hotfire testing. This incorporated a pair of high speed cameras to measure three-dimensional, real-time displacements and strains installed and operated under the extreme environments present on the test stand. The development process, setup and calibrations, data collection, hotfire test data collection and post-test analysis and results are presented in this paper.

  15. Compact, Automated, Frequency-Agile Microspectrofluorimeter

    NASA Technical Reports Server (NTRS)

    Fernandez, Salvador M.; Guignon, Ernest F.

    1995-01-01

    Compact, reliable, rugged, automated cell-culture and frequency-agile microspectrofluorimetric apparatus developed to perform experiments involving photometric imaging observations of single live cells. In original application, apparatus operates mostly unattended aboard spacecraft; potential terrestrial applications include automated or semiautomated diagnosis of pathological tissues in clinical laboratories, biomedical instrumentation, monitoring of biological process streams, and portable instrumentation for testing biological conditions in various environments. Offers obvious advantages over present laboratory instrumentation.

  16. Developing a Multimedia Instrument for Technical Vocabulary Learning: A Case of EFL Undergraduate Physics Education

    ERIC Educational Resources Information Center

    Rusanganwa, Joseph Appolinary

    2015-01-01

    The aim of the present study is to investigate the process of constructing a Multimedia Assisted Vocabulary Learning (MAVL) instrument at a university in Rwanda in 2009. The instrument is used in a one-computer classroom where students were taught in a foreign language and had little access to books. It consists of video clips featuring images,…

  17. Data Processing for the Space-Based Desis Hyperspectral Sensor

    NASA Astrophysics Data System (ADS)

    Carmona, E.; Avbelj, J.; Alonso, K.; Bachmann, M.; Cerra, D.; Eckardt, A.; Gerasch, B.; Graham, L.; Günther, B.; Heiden, U.; Kerr, G.; Knodt, U.; Krutz, D.; Krawcyk, H.; Makarau, A.; Miller, R.; Müller, R.; Perkins, R.; Walter, I.

    2017-05-01

    The German Aerospace Center (DLR) and Teledyne Brown Engineering (TBE) have established a collaboration to develop and operate a new space-based hyperspectral sensor, the DLR Earth Sensing Imaging Spectrometer (DESIS). DESIS will provide spacebased hyperspectral data in the VNIR with high spectral resolution and near-global coverage. While TBE provides the platform and infrastructure for operation of the DESIS instrument on the International Space Station, DLR is responsible for providing the instrument and the processing software. The DESIS instrument is equipped with novel characteristics for an imaging spectrometer such high spectral resolution (2.55 nm), a mirror pointing unit or a CMOS sensor operated in rolling shutter mode. We present here an overview of the DESIS instrument and its processing chain, emphasizing the effect of the novel characteristics of DESIS in the data processing and final data products. Furthermore, we analyse in more detail the effect of the rolling shutter on the DESIS data and possible mitigation/correction strategies.

  18. Clinical Physiologic Research Instrumentation: An Approach Using Modular Elements and Distributed Processing

    PubMed Central

    Hagen, R. W.; Ambos, H. D.; Browder, M. W.; Roloff, W. R.; Thomas, L. J.

    1979-01-01

    The Clinical Physiologic Research System (CPRS) developed from our experience in applying computers to medical instrumentation problems. This experience revealed a set of applications with a commonality in data acquisition, analysis, input/output, and control needs that could be met by a portable system. The CPRS demonstrates a practical methodology for integrating commercial instruments with distributed modular elements of local design in order to make facile responses to changing instrumentation needs in clinical environments. ImagesFigure 3

  19. Development of the Military Women's Attitudes Toward Menstrual Suppression Scale: from construct definition to pilot testing.

    PubMed

    Trego, Lori L

    2009-01-01

    The Military Women's Attitudes Toward Menstrual Suppression scale (MWATMS) was created to measure attitudes toward menstrual suppression during deployment. The human health and social ecology theories were integrated to conceptualize an instrument that accounts for military-unique aspects of the environment on attitudes toward suppression. A three-step instrument development process was followed to develop the MWATMS. The instrument was pilot tested on a convenience sample of 206 military women with deployment experience. Reliability was tested with measures of internal consistency (alpha = .97); validity was tested with principal components analysis with varimax rotation. Four components accounted for 65% of variance: Benefits/Interest, Hygiene, Convenience, and Soldier/Stress. The pilot test of the MWATMS supported its reliability and validity. Further testing is warranted for validation of this instrument.

  20. Teaching computer interfacing with virtual instruments in an object-oriented language.

    PubMed Central

    Gulotta, M

    1995-01-01

    LabVIEW is a graphic object-oriented computer language developed to facilitate hardware/software communication. LabVIEW is a complete computer language that can be used like Basic, FORTRAN, or C. In LabVIEW one creates virtual instruments that aesthetically look like real instruments but are controlled by sophisticated computer programs. There are several levels of data acquisition VIs that make it easy to control data flow, and many signal processing and analysis algorithms come with the software as premade VIs. In the classroom, the similarity between virtual and real instruments helps students understand how information is passed between the computer and attached instruments. The software may be used in the absence of hardware so that students can work at home as well as in the classroom. This article demonstrates how LabVIEW can be used to control data flow between computers and instruments, points out important features for signal processing and analysis, and shows how virtual instruments may be used in place of physical instrumentation. Applications of LabVIEW to the teaching laboratory are also discussed, and a plausible course outline is given. PMID:8580361

  1. Teaching computer interfacing with virtual instruments in an object-oriented language.

    PubMed

    Gulotta, M

    1995-11-01

    LabVIEW is a graphic object-oriented computer language developed to facilitate hardware/software communication. LabVIEW is a complete computer language that can be used like Basic, FORTRAN, or C. In LabVIEW one creates virtual instruments that aesthetically look like real instruments but are controlled by sophisticated computer programs. There are several levels of data acquisition VIs that make it easy to control data flow, and many signal processing and analysis algorithms come with the software as premade VIs. In the classroom, the similarity between virtual and real instruments helps students understand how information is passed between the computer and attached instruments. The software may be used in the absence of hardware so that students can work at home as well as in the classroom. This article demonstrates how LabVIEW can be used to control data flow between computers and instruments, points out important features for signal processing and analysis, and shows how virtual instruments may be used in place of physical instrumentation. Applications of LabVIEW to the teaching laboratory are also discussed, and a plausible course outline is given.

  2. Development Scaffolding for Construction of Evaluation Instrument Training Program on The Cognitive Domain For Senior High School Physics Teachers and The Same Level

    NASA Astrophysics Data System (ADS)

    Arif, W.; Suhandi, A.; Kaniawati, I.; Setiawan, A.

    2017-02-01

    The development of scaffolding for evaluation instrument construction training program on the cognitive domain for senior high school physics teacher and the same level that is specified in the test instrument has been done. This development was motivated by the low ability of the majority of physics teachers in constructing the physics learning achievement test. This situation not in accordance with the demands of Permendiknas RI no. 16 tahun 2007 concerning the standard of academic qualifications and competence of teachers, stating that teachers should have a good ability to develop instruments for assessment and evaluation of process and learning outcomes. Based on the preliminary study results, it can be seen that the main cause of the inability of teachers in developing physics achievement test is because they do not good understand of the indicators for each aspect of cognitive domains. Scaffolding development is done by using the research and development methods formulated by Thiagarajan which includes define, design and develope steps. Develop step includes build the scaffolding, validation of scaffolding by experts and the limited pilot implementations on the training activities. From the build scaffolding step, resulted the scaffolding for the construction of test instruments training program which include the process steps; description of indicators, operationalization of indicators, construction the itemsframework (items scenarios), construction the items stem, construction the items and checking the items. The results of the validation by three validator indicates that the built scaffolding are suitable for use in the construction of physics achievement test training program, especially for novice. The limited pilot implementation of the built scaffolding conducted in training activities attended by 10 senior high school physics teachers in Garut district. The results of the limited pilot implementation shows that the built scaffolding have a medium effectiveness in improving the ability of senior high school physics teachers in constructing the physic achievement test instrument that is characterized by more than 70% of trainees achieve scores of test instruments construction of about 80 or more.

  3. Development and validation of an instrument to measure nurse educator perceived confidence in clinical teaching.

    PubMed

    Nguyen, Van N B; Forbes, Helen; Mohebbi, Mohammadreza; Duke, Maxine

    2017-12-01

    Teaching nursing in clinical environments is considered complex and multi-faceted. Little is known about the role of the clinical nurse educator, specifically the challenges related to transition from clinician, or in some cases, from newly-graduated nurse to that of clinical nurse educator, as occurs in developing countries. Confidence in the clinical educator role has been associated with successful transition and the development of role competence. There is currently no valid and reliable instrument to measure clinical nurse educator confidence. This study was conducted to develop and psychometrically test an instrument to measure perceived confidence among clinical nurse educators. A multi-phase, multi-setting survey design was used. A total of 468 surveys were distributed, and 363 were returned. Data were analyzed using exploratory and confirmatory factor analyses. The instrument was successfully tested and modified in phase 1, and factorial validity was subsequently confirmed in phase 2. There was strong evidence of internal consistency, reliability, content, and convergent validity of the Clinical Nurse Educator Skill Acquisition Assessment instrument. The resulting instrument is applicable in similar contexts due to its rigorous development and validation process. © 2017 The Authors. Nursing & Health Sciences published by John Wiley & Sons Australia, Ltd.

  4. A Feminist Family Therapy Scale.

    ERIC Educational Resources Information Center

    Black, Leora; Piercy, Fred P.

    1991-01-01

    Reports on development and psychometric properties of Feminist Family Therapy Scale (FFTS), a 17-item instrument intended to reflect degree to which family therapists conceptualize process of family therapy from feminist-informed perspective. Found that the instrument discriminated between self-identified feminists and nonfeminists, women and men,…

  5. The development and testing of a qualitative instrument designed to assess critical thinking

    NASA Astrophysics Data System (ADS)

    Clauson, Cynthia Louisa

    This study examined a qualitative approach to assess critical thinking. An instrument was developed that incorporates an assessment process based on Dewey's (1933) concepts of self-reflection and critical thinking as problem solving. The study was designed to pilot test the critical thinking assessment process with writing samples collected from a heterogeneous group of students. The pilot test included two phases. Phase 1 was designed to determine the validity and inter-rater reliability of the instrument using two experts in critical thinking, problem solving, and literacy development. Validity of the instrument was addressed by requesting both experts to respond to ten questions in an interview. The inter-rater reliability was assessed by analyzing the consistency of the two experts' scorings of the 20 writing samples to each other, as well as to my scoring of the same 20 writing samples. Statistical analyses included the Spearman Rho and the Kuder-Richardson (Formula 20). Phase 2 was designed to determine the validity and reliability of the critical thinking assessment process with seven science teachers. Validity was addressed by requesting the teachers to respond to ten questions in a survey and interview. Inter-rater reliability was addressed by comparing the seven teachers' scoring of five writing samples with my scoring of the same five writing samples. Again, the Spearman Rho and the Kuder-Richardson (Formula 20) were used to determine the inter-rater reliability. The validity results suggest that the instrument is helpful as a guide for instruction and provides a systematic method to teach and assess critical thinking while problem solving with students in the classroom. The reliability results show the critical thinking assessment instrument to possess fairly high reliability when used by the experts, but weak reliability when used by classroom teachers. A major conclusion was drawn that teachers, as well as students, would need to receive instruction in critical thinking and in how to use the assessment process in order to gain more consistent interpretations of the six problem-solving steps. Specific changes needing to be made in the instrument to improve the quality are included.

  6. Developing evaluation instrument based on CIPP models on the implementation of portfolio assessment

    NASA Astrophysics Data System (ADS)

    Kurnia, Feni; Rosana, Dadan; Supahar

    2017-08-01

    This study aimed to develop an evaluation instrument constructed by CIPP model on the implementation of portfolio assessment in science learning. This study used research and development (R & D) method; adapting 4-D by the development of non-test instrument, and the evaluation instrument constructed by CIPP model. CIPP is the abbreviation of Context, Input, Process, and Product. The techniques of data collection were interviews, questionnaires, and observations. Data collection instruments were: 1) the interview guidelines for the analysis of the problems and the needs, 2) questionnaire to see level of accomplishment of portfolio assessment instrument, and 3) observation sheets for teacher and student to dig up responses to the portfolio assessment instrument. The data obtained was quantitative data obtained from several validators. The validators consist of two lecturers as the evaluation experts, two practitioners (science teachers), and three colleagues. This paper shows the results of content validity obtained from the validators and the analysis result of the data obtained by using Aikens' V formula. The results of this study shows that the evaluation instrument based on CIPP models is proper to evaluate the implementation of portfolio assessment instruments. Based on the experts' judgments, practitioners, and colleagues, the Aikens' V coefficient was between 0.86-1,00 which means that it is valid and can be used in the limited trial and operational field trial.

  7. SIRTF Science Operations System Design

    NASA Technical Reports Server (NTRS)

    Green, William

    1999-01-01

    SIRTF Science Operations System Design William B. Green Manager, SIRTF Science Center California Institute of Technology M/S 310-6 1200 E. California Blvd., Pasadena CA 91125 (626) 395 8572 Fax (626) 568 0673 bgreen@ipac.caltech.edu. The Space Infrared Telescope Facility (SIRTF) will be launched in December 2001, and perform an extended series of science observations at wavelengths ranging from 20 to 160 microns for five years or more. The California Institute of Technology has been selected as the home for the SIRTF Science Center (SSC). The SSC will be responsible for evaluating and selecting observation proposals, providing technical support to the science community, performing mission planning and science observation scheduling activities, instrument calibration during operations and instrument health monitoring, production of archival quality data products, and management of science research grants. The science payload consists of three instruments delivered by instrument Principal Investigators located at University of Arizona, Cornell, and Harvard Smithsonian Astrophysical Observatory. The SSC is responsible for design, development, and operation of the Science Operations System (SOS) which will support the functions assigned to the SSC by NASA. The SIRTF spacecraft, mission profile, and science instrument design have undergone almost ten years of refinement. SIRTF development and operations activities are highly cost constrained. The cost constraints have impacted the design of the SOS in several ways. The Science Operations System has been designed to incorporate a set of efficient, easy to use tools which will make it possible for scientists to propose observation sequences in a rapid and automated manner. The use of highly automated tools for requesting observations will simplify the long range observatory scheduling process, and the short term scheduling of science observations. Pipeline data processing will be highly automated and data-driven, utilizing a variety of tools developed at JPL, the instrument development teams, and Space Telescope Science Institute to automate processing. An incremental ground data system development approach has been adopted, featuring periodic deliveries that are validated with the flight hardware throughout the various phases of system level development and testing. This approach minimizes development time and decreases operations risk. This paper will describe the top level architecture of the SOS and the basic design concepts. A summary of the incremental development approach will be presented. Examples of the unique science user tools now under final development prior to the first proposal call scheduled for mid-2000 will be shown.

  8. Compact solar autoclave based on steam generation using broadband light-harvesting nanoparticles.

    PubMed

    Neumann, Oara; Feronti, Curtis; Neumann, Albert D; Dong, Anjie; Schell, Kevin; Lu, Benjamin; Kim, Eric; Quinn, Mary; Thompson, Shea; Grady, Nathaniel; Nordlander, Peter; Oden, Maria; Halas, Naomi J

    2013-07-16

    The lack of readily available sterilization processes for medicine and dentistry practices in the developing world is a major risk factor for the propagation of disease. Modern medical facilities in the developed world often use autoclave systems to sterilize medical instruments and equipment and process waste that could contain harmful contagions. Here, we show the use of broadband light-absorbing nanoparticles as solar photothermal heaters, which generate high-temperature steam for a standalone, efficient solar autoclave useful for sanitation of instruments or materials in resource-limited, remote locations. Sterilization was verified using a standard Geobacillus stearothermophilus-based biological indicator.

  9. ARM Mentor Selection Process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.

    2015-10-01

    The Atmospheric Radiation Measurement (ARM) Program was created in 1989 with funding from the U.S. Department of Energy (DOE) to develop several highly instrumented ground stations to study cloud formation processes and their influence on radiative transfer. In 2003, the ARM Program became a national scientific user facility, known as the ARM Climate Research Facility. This scientific infrastructure provides for fixed sites, mobile facilities, an aerial facility, and a data archive available for use by scientists worldwide through the ARM Climate Research Facility—a scientific user facility. The ARM Climate Research Facility currently operates more than 300 instrument systems that providemore » ground-based observations of the atmospheric column. To keep ARM at the forefront of climate observations, the ARM infrastructure depends heavily on instrument scientists and engineers, also known as lead mentors. Lead mentors must have an excellent understanding of in situ and remote-sensing instrumentation theory and operation and have comprehensive knowledge of critical scale-dependent atmospheric processes. They must also possess the technical and analytical skills to develop new data retrievals that provide innovative approaches for creating research-quality data sets. The ARM Climate Research Facility is seeking the best overall qualified candidate who can fulfill lead mentor requirements in a timely manner.« less

  10. An Undergraduate Student Instrumentation Project (USIP) to Develop New Instrument Technology to Study the Auroral Ionosphere and Stratospheric Ozone Layer Using Ultralight Balloon Payloads

    NASA Astrophysics Data System (ADS)

    Gamblin, R.; Marrero, E.; Bering, E. A., III; Leffer, B.; Dunbar, B.; Ahmad, H.; Canales, D.; Bias, C.; Cao, J.; Pina, M.; Ehteshami, A.; Hermosillo, D.; Siddiqui, A.; Guala, D.

    2014-12-01

    This project is currently engaging tweleve undergraduate students in the process of developing new technology and instrumentation for use in balloon borne geospace investigations in the auroral zone. Motivation stems from advances in microelectronics and consumer electronic technology. Given the technological inovations over the past 20 years it now possible to develop new instrumentation to study the auroral ionosphere and stratospheric ozone layer using ultralight balloon payloads for less than 6lbs and $3K per payload. The UH USIP undergraduate team is currently in the process of build ten such payloads for launch using1500 gm latex weather balloons to be deployed in Houston and Fairbanks, AK as well as zero pressure balloons launched from northern Sweden. The latex balloon project will collect vertical profiles of wind speed, wind direction, temperature, electrical conductivity, ozone and odd nitrogen. This instrument payload will also profiles of pressure, electric field, and air-earth electric current. The zero pressure balloons will obtain a suite of geophysical measurements including: DC electric field, electric field and magnetic flux, optical imaging, total electron content of ionosphere via dual-channel GPS, X-ray detection, and infrared/UV spectroscopy. Students will fly payloads with different combinations of these instruments to determine which packages are successful. Data collected by these instruments will be useful in understanding the nature of electrodynamic coupling in the upper atmosphere and how the global earth system is changing. Results and best practices learned from lab tests and initial Houston test flights will be discussed.

  11. Instrumentation for optimizing an underground coal-gasification process

    NASA Astrophysics Data System (ADS)

    Seabaugh, W.; Zielinski, R. E.

    1982-06-01

    While the United States has a coal resource base of 6.4 trillion tons, only seven percent is presently recoverable by mining. The process of in-situ gasification can recover another twenty-eight percent of the vast resource, however, viable technology must be developed for effective in-situ recovery. The key to this technology is system that can optimize and control the process in real-time. An instrumentation system is described that optimizes the composition of the injection gas, controls the in-situ process and conditions the product gas for maximum utilization. The key elements of this system are Monsanto PRISM Systems, a real-time analytical system, and a real-time data acquisition and control system. This system provides from complete automation of the process but can easily be overridden by manual control. The use of this cost effective system can provide process optimization and is an effective element in developing a viable in-situ technology.

  12. What is a good general practitioner (GP)? The development and evaluation of a multi-source feedback instrument for GP appraisal.

    PubMed

    Shepherd, Annabel; Lough, Murray

    2010-05-01

    Although multi-source feedback (MSF) has been used in primary healthcare, the development of an MSF instrument specific to this setting in the UK has not been previously described. The aims of this study were to develop and evaluate an MSF instrument for GPs in Scotland taking part in appraisal. The members of ten primary healthcare teams in the west of Scotland were asked to provide comments in answer to the question, 'What is a good GP?'. The data were reduced and coded by two researchers and questions were devised. Following content validity testing the MSF process was evaluated with volunteers using face-to-face interviews and a postal survey. Thirty-seven statements covering the six domains of communication skills, professional values, clinical care, working with colleagues, personality issues and duties and responsibilities were accepted as relevant by ten primary healthcare teams using a standard of 80 percent agreement. The evaluation found the MSF process to be feasible and acceptable and participants provided some evidence of educational impact. An MSF instrument for GPs has been developed based on the concept of 'the good GP' as described by the primary healthcare team. The evaluation of the resultant MSF process illustrates the potential of MSF, when delivered in the supportive environment of GP appraisal, to provide feedback which has the possibility of improving working relationships between GPs and their colleagues.

  13. Identification of musical instruments by normal-hearing subjects listening through a cochlear-implant simulation

    NASA Astrophysics Data System (ADS)

    Reich, Rebecca D.; Eddington, Donald

    2002-05-01

    Signal processing in a cochlear implant (CI) is primarily designed to convey speech and environmental sounds, and can cause distortion of musical timbre. Systematic investigation of musical instrument identification through a CI has not yet revealed how timbre is affected by the implant's processing. In this experiment, the bandpass filtering, rectification, and low-pass filtering of an implant are simulated in MATLAB. Synthesized signals representing 12 common instruments, each performing a major scale, are processed by simulations using up to 8 analysis channels. The unprocessed recordings, together with the 8 simulation conditions for 12 instruments, are presented in random order to each of the subjects. The subject's task is to identify the instrument represented by each item. The subjects also subjectively score each item based on similarity and pleasantness. We anticipate performance using the simulation will be worse than the unprocessed condition because of the limited information delivered by the envelopes of the analysis channels. These results will be analyzed as a confusion matrix and provide a basis for contrasting the information used by subjects listening to the unprocessed and processed materials. Understanding these differences should aid in the development of new processing strategies to better represent music for cochlear implant users.

  14. Use of Synthetic Single-Stranded Oligonucleotides as Artificial Test Soiling for Validation of Surgical Instrument Cleaning Processes

    PubMed Central

    Wilhelm, Nadja; Perle, Nadja; Simmoteit, Robert; Schlensak, Christian; Wendel, Hans P.; Avci-Adali, Meltem

    2014-01-01

    Surgical instruments are often strongly contaminated with patients' blood and tissues, possibly containing pathogens. The reuse of contaminated instruments without adequate cleaning and sterilization can cause postoperative inflammation and the transmission of infectious diseases from one patient to another. Thus, based on the stringent sterility requirements, the development of highly efficient, validated cleaning processes is necessary. Here, we use for the first time synthetic single-stranded DNA (ssDNA_ODN), which does not appear in nature, as a test soiling to evaluate the cleaning efficiency of routine washing processes. Stainless steel test objects were coated with a certain amount of ssDNA_ODN. After cleaning, the amount of residual ssDNA_ODN on the test objects was determined using quantitative real-time PCR. The established method is highly specific and sensitive, with a detection limit of 20 fg, and enables the determination of the cleaning efficiency of medical cleaning processes under different conditions to obtain optimal settings for the effective cleaning and sterilization of instruments. The use of this highly sensitive method for the validation of cleaning processes can prevent, to a significant extent, the insufficient cleaning of surgical instruments and thus the transmission of pathogens to patients. PMID:24672793

  15. Significant achievements in the planetary geology program, 1981

    NASA Technical Reports Server (NTRS)

    Mouginis-Mark, P. J.

    1982-01-01

    Recent developments in planetology research are summarized. Important developments are summarized in topics ranging from solar system evolution, comparative planetology, and geologic processes, to techniques and instrument development for future exploration.

  16. Thermal vacuum chamber repressurization with instrument purging

    NASA Astrophysics Data System (ADS)

    Woronowicz, Michael S.

    2016-09-01

    At the conclusion of cryogenic vacuum testing of the James Webb Space Telescope Optical Telescope Element Integrated Science Instrument Module (JWST-OTIS) in NASA Johnson Space Center's (JSCs) thermal vacuum (TV) Chamber A, contamination control (CC) engineers are postulating that chamber particulate material stirred up by the repressurization process may be kept from falling into the Integrated Science Instrument Module (ISIM) interior to some degree by activating instrument purge flows over some initial period before opening the chamber valves. This manuscript describes development of a series of models designed to describe this process. The models are strung together in tandem with a fictitious set of conditions to estimate overpressure evolution from which net outflow velocity behavior may be obtained. Creeping flow assumptions are then used to determine the maximum particle size that may be kept suspended above the ISIM aperture, keeping smaller particles from settling within the instrument module.

  17. Thermal Vacuum Chamber Repressurization with Instrument Purging

    NASA Technical Reports Server (NTRS)

    Woronowicz, Michael S.

    2014-01-01

    At the conclusion of cryogenic vacuum testing of the James Webb Space Telescope Optical Telescope Element Integrated Science Instrument Module (JWST-OTIS) in NASA Johnson Space Center’s (JSCs) thermal vacuum (TV) Chamber A, contamination control (CC) engineers are postulating that chamber particulate material stirred up by the repressurization process may be kept from falling into the Integrated Science Instrument Module (ISIM) interior to some degree by activating instrument purge flows over some initial period before opening the chamber valves. This manuscript describes development of a series of models designed to describe this process. The models are strung together in tandem with a fictitious set of conditions to estimate overpressure evolution from which net outflow velocity behavior may be obtained. Creeping flow assumptions are then used to determine the maximum particle size that may be kept suspended above the ISIM aperture, keeping smaller particles from settling within the instrument module.

  18. The development of a science process assessment for fourth-grade students

    NASA Astrophysics Data System (ADS)

    Smith, Kathleen A.; Welliver, Paul W.

    In this study, a multiple-choice test entitled the Science Process Assessment was developed to measure the science process skills of students in grade four. Based on the Recommended Science Competency Continuum for Grades K to 6 for Pennsylvania Schools, this instrument measured the skills of (1) observing, (2) classifying, (3) inferring, (4) predicting, (5) measuring, (6) communicating, (7) using space/time relations, (8) defining operationally, (9) formulating hypotheses, (10) experimenting, (11) recognizing variables, (12) interpreting data, and (13) formulating models. To prepare the instrument, classroom teachers and science educators were invited to participate in two science education workshops designed to develop an item bank of test questions applicable to measuring process skill learning. Participants formed writing teams and generated 65 test items representing the 13 process skills. After a comprehensive group critique of each item, 61 items were identified for inclusion into the Science Process Assessment item bank. To establish content validity, the item bank was submitted to a select panel of science educators for the purpose of judging item acceptability. This analysis yielded 55 acceptable test items and produced the Science Process Assessment, Pilot 1. Pilot 1 was administered to 184 fourth-grade students. Students were given a copy of the test booklet; teachers read each test aloud to the students. Upon completion of this first administration, data from the item analysis yielded a reliability coefficient of 0.73. Subsequently, 40 test items were identified for the Science Process Assessment, Pilot 2. Using the test-retest method, the Science Process Assessment, Pilot 2 (Test 1 and Test 2) was administered to 113 fourth-grade students. Reliability coefficients of 0.80 and 0.82, respectively, were ascertained. The correlation between Test 1 and Test 2 was 0.77. The results of this study indicate that (1) the Science Process Assessment, Pilot 2, is a valid and reliable instrument applicable to measuring the science process skills of students in grade four, (2) using educational workshops as a means of developing item banks of test questions is viable and productive in the test development process, and (3) involving classroom teachers and science educators in the test development process is educationally efficient and effective.

  19. Factor analysis methods and validity evidence: A systematic review of instrument development across the continuum of medical education

    NASA Astrophysics Data System (ADS)

    Wetzel, Angela Payne

    Previous systematic reviews indicate a lack of reporting of reliability and validity evidence in subsets of the medical education literature. Psychology and general education reviews of factor analysis also indicate gaps between current and best practices; yet, a comprehensive review of exploratory factor analysis in instrument development across the continuum of medical education had not been previously identified. Therefore, the purpose for this study was critical review of instrument development articles employing exploratory factor or principal component analysis published in medical education (2006--2010) to describe and assess the reporting of methods and validity evidence based on the Standards for Educational and Psychological Testing and factor analysis best practices. Data extraction of 64 articles measuring a variety of constructs that have been published throughout the peer-reviewed medical education literature indicate significant errors in the translation of exploratory factor analysis best practices to current practice. Further, techniques for establishing validity evidence tend to derive from a limited scope of methods including reliability statistics to support internal structure and support for test content. Instruments reviewed for this study lacked supporting evidence based on relationships with other variables and response process, and evidence based on consequences of testing was not evident. Findings suggest a need for further professional development within the medical education researcher community related to (1) appropriate factor analysis methodology and reporting and (2) the importance of pursuing multiple sources of reliability and validity evidence to construct a well-supported argument for the inferences made from the instrument. Medical education researchers and educators should be cautious in adopting instruments from the literature and carefully review available evidence. Finally, editors and reviewers are encouraged to recognize this gap in best practices and subsequently to promote instrument development research that is more consistent through the peer-review process.

  20. Measuring organizational readiness for knowledge translation in chronic care.

    PubMed

    Gagnon, Marie-Pierre; Labarthe, Jenni; Légaré, France; Ouimet, Mathieu; Estabrooks, Carole A; Roch, Geneviève; Ghandour, El Kebir; Grimshaw, Jeremy

    2011-07-13

    Knowledge translation (KT) is an imperative in order to implement research-based and contextualized practices that can answer the numerous challenges of complex health problems. The Chronic Care Model (CCM) provides a conceptual framework to guide the implementation process in chronic care. Yet, organizations aiming to improve chronic care require an adequate level of organizational readiness (OR) for KT. Available instruments on organizational readiness for change (ORC) have shown limited validity, and are not tailored or adapted to specific phases of the knowledge-to-action (KTA) process. We aim to develop an evidence-based, comprehensive, and valid instrument to measure OR for KT in healthcare. The OR for KT instrument will be based on core concepts retrieved from existing literature and validated by a Delphi study. We will specifically test the instrument in chronic care that is of an increasing importance for the health system. Phase one: We will conduct a systematic review of the theories and instruments assessing ORC in healthcare. The retained theoretical information will be synthesized in a conceptual map. A bibliography and database of ORC instruments will be prepared after appraisal of their psychometric properties according to the standards for educational and psychological testing. An online Delphi study will be carried out among decision makers and knowledge users across Canada to assess the importance of these concepts and measures at different steps in the KTA process in chronic care.Phase two: A final OR for KT instrument will be developed and validated both in French and in English and tested in chronic disease management to measure OR for KT regarding the adoption of comprehensive, patient-centered, and system-based CCMs. This study provides a comprehensive synthesis of current knowledge on explanatory models and instruments assessing OR for KT. Moreover, this project aims to create more consensus on the theoretical underpinnings and the instrumentation of OR for KT in chronic care. The final product--a comprehensive and valid OR for KT instrument--will provide the chronic care settings with an instrument to assess their readiness to implement evidence-based chronic care.

  1. Measuring organizational readiness for knowledge translation in chronic care

    PubMed Central

    2011-01-01

    Background Knowledge translation (KT) is an imperative in order to implement research-based and contextualized practices that can answer the numerous challenges of complex health problems. The Chronic Care Model (CCM) provides a conceptual framework to guide the implementation process in chronic care. Yet, organizations aiming to improve chronic care require an adequate level of organizational readiness (OR) for KT. Available instruments on organizational readiness for change (ORC) have shown limited validity, and are not tailored or adapted to specific phases of the knowledge-to-action (KTA) process. We aim to develop an evidence-based, comprehensive, and valid instrument to measure OR for KT in healthcare. The OR for KT instrument will be based on core concepts retrieved from existing literature and validated by a Delphi study. We will specifically test the instrument in chronic care that is of an increasing importance for the health system. Methods Phase one: We will conduct a systematic review of the theories and instruments assessing ORC in healthcare. The retained theoretical information will be synthesized in a conceptual map. A bibliography and database of ORC instruments will be prepared after appraisal of their psychometric properties according to the standards for educational and psychological testing. An online Delphi study will be carried out among decision makers and knowledge users across Canada to assess the importance of these concepts and measures at different steps in the KTA process in chronic care. Phase two: A final OR for KT instrument will be developed and validated both in French and in English and tested in chronic disease management to measure OR for KT regarding the adoption of comprehensive, patient-centered, and system-based CCMs. Discussion This study provides a comprehensive synthesis of current knowledge on explanatory models and instruments assessing OR for KT. Moreover, this project aims to create more consensus on the theoretical underpinnings and the instrumentation of OR for KT in chronic care. The final product--a comprehensive and valid OR for KT instrument--will provide the chronic care settings with an instrument to assess their readiness to implement evidence-based chronic care. PMID:21752264

  2. Equipped for Change: Development and Implementation of a Case Statement at an Urban Community College

    ERIC Educational Resources Information Center

    Krishnan, Sathasivam

    2010-01-01

    This action research study examined the process of creation and implementation of a case statement for an urban community college foundation. An instrumental case study methodology was used in examining this process. The study chronicled a successful participatory development process that allowed a number of stakeholders to effectively work on…

  3. The Geostationary Fourier Transform Spectrometer

    NASA Technical Reports Server (NTRS)

    Key, Richard; Sander, Stanley; Eldering, Annmarie; Miller, Charles; Frankenberg, Christian; Natra, Vijay; Rider, David; Blavier, Jean-Francois; Bekker, Dmitriy; Wu, Yen-Hung

    2012-01-01

    The Geostationary Fourier Transform Spectrometer (GeoFTS) is an imaging spectrometer designed for an earth science mission to measure key atmospheric trace gases and process tracers related to climate change and human activity. The GeoFTS instrument is a half meter cube size instrument designed to operate in geostationary orbit as a secondary "hosted" payload on a commercial geostationary satellite mission. The advantage of GEO is the ability to continuously stare at a region of the earth, enabling frequent sampling to capture the diurnal variability of biogenic fluxes and anthropogenic emissions from city to continental scales. The science goal is to obtain a process-based understanding of the carbon cycle from simultaneous high spatial resolution measurements of carbon dioxide (CO2), methane (CH4), carbon monoxide (CO), and chlorophyll fluorescence (CF) many times per day in the near infrared spectral region to capture their spatial and temporal variations on diurnal, synoptic, seasonal and interannual time scales. The GeoFTS instrument is based on a Michelson interferometer design with a number of advanced features incorporated. Two of the most important advanced features are the focal plane arrays and the optical path difference mechanism. A breadboard GeoFTS instrument has demonstrated functionality for simultaneous measurements in the visible and IR in the laboratory and subsequently in the field at the California Laboratory for Atmospheric Remote Sensing (CLARS) observatory on Mt. Wilson overlooking the Los Angeles basin. A GeoFTS engineering model instrument is being developed which will make simultaneous visible and IR measurements under space flight like environmental conditions (thermal-vacuum at 180 K). This will demonstrate critical instrument capabilities such as optical alignment stability, interferometer modulation efficiency, and high throughput FPA signal processing. This will reduce flight instrument development risk and show that the GeoFTS design is mature and flight ready.

  4. The Development of a Clinical Screening Instrument For Tumour Predisposition Syndromes In Childhood Cancer Patients

    PubMed Central

    Hopman, Saskia M. J.; Merks, Johannes H. M.; de Borgie, Corianne A. J. M.; Aalfs, C. M.; Biesecker, Leslie G.; Cole, Trevor; Eng, Charis; Legius, Eric; Maher, Eamonn R.; van Noesel, Max M.; Verloes, Alain; Viskochil, David H.; Wagner, Anja; Weksberg, Rosanna; Caron, Huib N.; Hennekam, Raoul C. M.

    2014-01-01

    Background Identification of tumour predisposition syndromes in patients who have cancer in childhood is paramount for optimal care. A screening instrument that can help to identify such patients will facilitate physicians caring for children with cancer. The complete screening instrument should consist of a standardized series of pictures and a screening form for manifestations not visible in the pictures. Here we describe the development of such a screening form based on an international two-stage Delphi process and an initial validation of the complete instrument. Patients and Methods We identified manifestations that may contribute to the diagnosis of a tumour predisposition syndrome through the Winter-Baraitser Dysmorphology Database and the textbook “Gorlin's Syndromes of the Head and Neck”. In a two-round Delphi process, eight international content-experts scored the contribution of each of these manifestations. We performed a clinical validation of the instrument in a selected cohort of ten paediatric cancer patients from another centre. Results In total, 49 manifestations were found to contribute to the diagnosis of a tumour predisposition syndrome and were included in the screening form. The pilot validation study showed that patients suspect for having a tumour predisposition syndrome were recognized. Excellent correlation for indication for referral of a patient between the screening instrument and the reference standard (personal evaluation by an experienced clinical geneticist) was found.). Conclusions The Delphi process performed by international specialists with a function as opinion leaders in their field of expertise has led to a screening form and instrument with which those childhood cancer patients can be identified who may have a tumour predisposition syndrome and thus have an indication to be referred for further genetic analysis. PMID:23855994

  5. Nimbus/TOMS Science Data Operations Support

    NASA Technical Reports Server (NTRS)

    Childs, Jeff

    1998-01-01

    1. Participate in and provide analysis of laboratory and in-flight calibration of UV sensors used for space observations of backscattered UV radiation. 2. Provide support to the TOMS Science Operations Center, including generating instrument command lists and analysis of TOMS health and safety data. 3. Develop and maintain software and algorithms designed to capture and process raw spacecraft and instrument data, convert the instrument output into measured radiance and irradiances, and produce scientifically valid products. 4. Process the TOMS data into Level 1, Level 2, and Level 3 data products. 5. Provide analysis of the science data products in support of NASA GSFC Code 916's research.

  6. Nimbus/TOMS Science Data Operations Support

    NASA Technical Reports Server (NTRS)

    1998-01-01

    Projected goals include the following: (1) Participate in and provide analysis of laboratory and in-flight calibration of LTV sensors used for space observations of backscattered LTV radiation; (2) Provide support to the TOMS Science Operations Center, including generating instrument command lists and analysis of TOMS health and safety data; (3) Develop and maintain software and algorithms designed to capture and process raw spacecraft and instrument data, convert the instrument output into measured radiance and irradiances, and produce scientifically valid products; (4) Process the TOMS data into Level 1, Level 2, and Level 3 data products; (5) Provide analysis of the science data products in support of NASA GSFC Code 916's research.

  7. Organizational Conflict Management as Disputing Process: The Problem of Social Escalation.

    ERIC Educational Resources Information Center

    Morrill, Calvin; Thomas, Cheryl King

    1992-01-01

    Develops an instrument to study organizational conflict management as a disputing process involving the social escalation from grievance to conflict and dispute stages. Finds differences in dispute process according to different strengths of informal relations. (SR)

  8. An Instrument to Assess Self-Statements During Public Speaking: Scale Development and Preliminary Psychometric Properties

    PubMed Central

    Hofmann, Stefan G.; DiBartolo, Patricia Marten

    2006-01-01

    Public speaking is the most commonly reported fearful social situation. Although a number of contemporary theories emphasize the importance of cognitive processes in social anxiety, there is no instrument available to assess fearful thoughts experienced during public speaking. The Self-Statements During Public Speaking (SSPS) scale is a 10-item questionnaire consisting of two 5-item subscales, the “Positive Self-Statements” (SSPS-P) and the “Negative Self-Statements” subscale (SSPS-N). Four studies report on the development and the preliminary psychometric properties of this instrument. PMID:16763666

  9. The Airborne Ocean Color Imager - System description and image processing

    NASA Technical Reports Server (NTRS)

    Wrigley, Robert C.; Slye, Robert E.; Klooster, Steven A.; Freedman, Richard S.; Carle, Mark; Mcgregor, Lloyd F.

    1992-01-01

    The Airborne Ocean Color Imager was developed as an aircraft instrument to simulate the spectral and radiometric characteristics of the next generation of satellite ocean color instrumentation. Data processing programs have been developed as extensions of the Coastal Zone Color Scanner algorithms for atmospheric correction and bio-optical output products. The latter include several bio-optical algorithms for estimating phytoplankton pigment concentration, as well as one for the diffuse attenuation coefficient of the water. Additional programs have been developed to geolocate these products and remap them into a georeferenced data base, using data from the aircraft's inertial navigation system. Examples illustrate the sequential data products generated by the processing system, using data from flightlines near the mouth of the Mississippi River: from raw data to atmospherically corrected data, to bio-optical data, to geolocated data, and, finally, to georeferenced data.

  10. Innovation management based on proactive engagement of customers: A case study on LEGO Group. Part II: Challenge of engaging the digital customer

    NASA Astrophysics Data System (ADS)

    Avasilcăi, S.; Rusu, G.

    2015-11-01

    To foster the development of innovative products and new technologies, nowadays companies use an open innovation system, encouraging stakeholders to contribute, using the companies’ online platforms for open innovation or social media, bringing and sharing creative solutions and ideas in order to respond to challenging needs the company directly expresses. Accordingly, the current research continues the analysis of the LEGO Group innovation efforts, aiming to provide a case study approach based on describing the most important projects and online instruments company uses to interact with customers and other external stakeholders. Thus, by analysing the experience of the company in developing projects of involving stakeholders in the innovation processes, the article emphasizes the objective of these past projects developed by LEGO Group, outlining their objectives regarding the focus on the product or process innovation, the team management and stakeholders involved in the innovation actions and the results they obtained. Moreover, the case study highlights the features of the most important online instruments LEGO Group uses at the moment for engaging LEGO fans, children, parents, and other external stakeholders in developing new LEGO sets. Thus, LEGO online instruments provide the opportunity for customers to be creative and to respond to LEGO management team challenges. Accordingly, LEGO involve customers in bringing innovative ideas for LEGO sets through LEGO Ideas instrument, which aims to engage customers in submitting projects, voting and supporting ideas and also sharing them on social media. Also, the research emphasizes the role of supporting the open dialogue and interaction with customers and other external stakeholders through LEGO.com Create & Share Galleries instrument, using their creativity to upload innovative models in the public galleries. The continuous challenges LEGO launches for their fans create a long-term connection between company and its customers, supporting the value co-creation process, as the submitted ideas can materialize in new LEGO products which can be found on the market. As a consequence, customers’ engagement in the co-creation process facilitated by the multiple online instruments provided by LEGO, resulted in positive outcomes for the company regarding new product development for the sets launched on the market to satisfy changing needs of their customers. The results provided by this case study approach can be useful for the business environment and academia as well in order to understand the role of engaging customers in the open innovation process, creating a competitive advantage on the market for companies.

  11. The Stahl Multidimensional Inventory of Values and Attitudes (SMIVA): A Report on the Development of an Instrument to Measure the Effects of One Approach to Values Education.

    ERIC Educational Resources Information Center

    Stahl, Robert J.

    1986-01-01

    Reports the steps taken to develop a satisfactory group measure of the Casteel-Stahl model of cognitive-affect-process education. The resulting 60-item Likert format instrument measures a wide array of instructional outcomes, from empathy, communications, decision making, problem solving and personal consistency to acceptance of self and…

  12. An update on the development of IO:I: a NIR imager for the Liverpool Telescope

    NASA Astrophysics Data System (ADS)

    Barnsley, R. M.; Steele, I. A.; Bates, S. D.; Mottram, C. J.

    2014-07-01

    IO:I is a new instrument in development for the Liverpool Telescope, extending current imaging capabilities beyond the optical and into the near infrared. Cost has been minimised by use of a previously decommissioned instrument's dewar as the base for a prototype, and retrofitting it with a 1.7μm cutoff Hawaii-2RG HgCdTe detector, SIDECAR ASIC controller and JADE2 interface card. Development of this prototype is nearing completion and will be operational mid 2014. In this paper, the mechanical, electronic and cryogenic facets of the dewar retrofitting process will be discussed together with a description of the instrument control system software/hardware setup. Finally, a brief overview of some initial testing undertaken on the engineering grade array will be given, along with future commissioning plans for the instrument.

  13. Pain assessment in children: theoretical and empirical validity.

    PubMed

    Villarruel, A M; Denyes, M J

    1991-12-01

    Valid assessment of pain in children is foundational for both the nursing practice and research domains, yet few validated methods of pain measurement are currently available for young children. This article describes an innovative research approach used in the development of photographic instruments to measure pain intensity in young African-American and Hispanic children. The instruments were designed to enable children to participate actively in their own care and to do so in ways that are congruent with their developmental and cultural heritage. Conceptualization of the instruments, methodological development, and validation processes grounded in Orem's Self-Care Deficit Theory of Nursing are described. The authors discuss the ways in which the gaps between nursing theory, research, and practice are narrowed when development of instruments to measure clinical nursing phenomena are grounded in nursing theory, validated through research and utilized in practice settings.

  14. The Job Training and Job Satisfaction Survey Technical Manual

    ERIC Educational Resources Information Center

    Schmidt, Steven W.

    2004-01-01

    Job training has become an important aspect of an employee's overall job experience. However, it is not often called out specifically on instruments measuring job satisfaction. This technical manual details the processes used in the development and validation of a survey instrument to measure job training satisfaction and overall job…

  15. Instrumentation for optical ocean remote sensing

    NASA Technical Reports Server (NTRS)

    Esaias, W. E.

    1991-01-01

    Instruments used in ocean color remote sensing algorithm development, validation, and data acquisition which have the potential for further commercial development and marketing are discussed. The Ocean Data Acquisition System (ODAS) is an aircraft-borne radiometer system suitable for light aircraft, which has applications for rapid measurement of chlorophyll pigment concentrations along the flight line. The instrument package includes a three channel radiometer system for upwelling radiance, an infrared temperature sensor, a three-channel downwelling irradiance sensor, and Loran-C navigation. Data are stored on a PC and processed to transects or interpolated 'images' on the ground. The instrument has been in operational use for two and one half years. The accuracy of pigment concentrations from the instrument is quite good, even in complex Chesapeake Bay waters. To help meet the requirement for validation of future satellite missions, a prototype air-deployable drifting buoy for measurement of near-surface upwelled radiance in multiple channnels is undergoing test deployment. The optical drifter burst samples radiance, stores and processes the data, and uses the Argos system as a data link. Studies are underway to explore the limits to useful lifetime with respect to power and fouling.

  16. Automatic performance budget: towards a risk reduction

    NASA Astrophysics Data System (ADS)

    Laporte, Philippe; Blake, Simon; Schmoll, Jürgen; Rulten, Cameron; Savoie, Denis

    2014-08-01

    In this paper, we discuss the performance matrix of the SST-GATE telescope developed to allow us to partition and allocate the important characteristics to the various subsystems as well as to describe the process in order to verify that the current design will deliver the required performance. Due to the integrated nature of the telescope, a large number of parameters have to be controlled and effective calculation tools must be developed such as an automatic performance budget. Its main advantages consist in alleviating the work of the system engineer when changes occur in the design, in avoiding errors during any re-allocation process and recalculate automatically the scientific performance of the instrument. We explain in this paper the method to convert the ensquared energy (EE) and the signal-to-noise ratio (SNR) required by the science cases into the "as designed" instrument. To ensure successful design, integration and verification of the next generation instruments, it is of the utmost importance to have methods to control and manage the instrument's critical performance characteristics at its very early design steps to limit technical and cost risks in the project development. Such a performance budget is a tool towards this goal.

  17. WFIRST: Update on the Coronagraph Science Requirements

    NASA Astrophysics Data System (ADS)

    Douglas, Ewan S.; Cahoy, Kerri; Carlton, Ashley; Macintosh, Bruce; Turnbull, Margaret; Kasdin, Jeremy; WFIRST Coronagraph Science Investigation Teams

    2018-01-01

    The WFIRST Coronagraph instrument (CGI) will enable direct imaging and low resolution spectroscopy of exoplanets in reflected light and imaging polarimetry of circumstellar disks. The CGI science investigation teams were tasked with developing a set of science requirements which advance our knowledge of exoplanet occurrence and atmospheric composition, as well as the composition and morphology of exozodiacal debris disks, cold Kuiper Belt analogs, and protoplanetary systems. We present the initial content, rationales, validation, and verification plans for the WFIRST CGI, informed by detailed and still-evolving instrument and observatory performance models. We also discuss our approach to the requirements development and management process, including the collection and organization of science inputs, open source approach to managing the requirements database, and the range of models used for requirements validation. These tools can be applied to requirements development processes for other astrophysical space missions, and may ease their management and maintenance. These WFIRST CGI science requirements allow the community to learn about and provide insights and feedback on the expected instrument performance and science return.

  18. Reusing Joint Polar Satellite System (jpss) Ground System Components to Process AURA Ozone Monitoring Instrument (omi) Science Products

    NASA Astrophysics Data System (ADS)

    Moses, J. F.; Jain, P.; Johnson, J.; Doiron, J. A.

    2017-12-01

    New Earth observation instruments are planned to enable advancements in Earth science research over the next decade. Diversity of Earth observing instruments and their observing platforms will continue to increase as new instrument technologies emerge and are deployed as part of National programs such as Joint Polar Satellite System (JPSS), Geostationary Operational Environmental Satellite system (GOES), Landsat as well as the potential for many CubeSat and aircraft missions. The practical use and value of these observational data often extends well beyond their original purpose. The practicing community needs intuitive and standardized tools to enable quick unfettered development of tailored products for specific applications and decision support systems. However, the associated data processing system can take years to develop and requires inherent knowledge and the ability to integrate increasingly diverse data types from multiple sources. This paper describes the adaptation of a large-scale data processing system built for supporting JPSS algorithm calibration and validation (Cal/Val) node to a simplified science data system for rapid application. The new configurable data system reuses scalable JAVA technologies built for the JPSS Government Resource for Algorithm Verification, Independent Test, and Evaluation (GRAVITE) system to run within a laptop environment and support product generation and data processing of AURA Ozone Monitoring Instrument (OMI) science products. Of particular interest are the root requirements necessary for integrating experimental algorithms and Hierarchical Data Format (HDF) data access libraries into a science data production system. This study demonstrates the ability to reuse existing Ground System technologies to support future missions with minimal changes.

  19. Wettability measurement apparatus for porous material using the modified Washburn method

    NASA Astrophysics Data System (ADS)

    Thakker, Manish; Karde, Vikram; Shah, Dinesh O.; Shukla, Premal; Ghoroi, Chinmay

    2013-12-01

    In this work a cost-effective instrument for measuring the wettability of powder materials was designed and developed, which works on the modified Washburn method. The instrument measures the mass gain against time due to penetration of the liquid into the powder materials using a microbalance and LabVIEW-based data acquisition system. The wettability characteristic of different powders was determined from the contact angle using the modified Washburn equation. To demonstrate the performance of the developed instrument, the wettability of as-received corn starch and nano-coated corn starch powders was estimated with water as a test liquid. The corn starch powders coated with hydrophilic grade (Aerosil 200P) and hydrophobic grade (Aerosil R972) nanoparticles at different coating levels showed expected changes in their contact angle. Some of the results were also verified against the available standard instrument for wettability measurement and found to be consistent. The present configuration of the instrument costs about 500 US which is 15 to 20 times less than the available advanced models. The developed instrument is thus a cost-effective solution for wettability measurement which can be used for materials in food processing, pharmaceuticals, horticulture, textile manufacturing, civil engineering etc. The developed instrument is expected to help many small scale industries or research labs who cannot afford an expensive instrument for wettability studies.

  20. Speech systems research at Texas Instruments

    NASA Technical Reports Server (NTRS)

    Doddington, George R.

    1977-01-01

    An assessment of automatic speech processing technology is presented. Fundamental problems in the development and the deployment of automatic speech processing systems are defined and a technology forecast for speech systems is presented.

  1. The Gem Infrasound Logger and Custom-Built Instrumentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Jacob F.; Johnson, Jeffrey B.; Bowman, Daniel C.

    Here, we designed, built, and recorded data with a custom infrasound logger (referred to as the Gem) that is inexpensive, portable, and easy to use. We also describe its design process, qualities, and applications in this article. Field instrumentation is a key element of geophysical data collection, and the quantity and quality of data that can be recorded is determined largely by the characteristics of the instruments used. Geophysicists tend to rely on commercially available instruments, which suffice for many important types of fieldwork. However, commercial instrumentation can fall short in certain roles, which motivates the development of custom sensorsmore » and data loggers. Particularly, we found existing data loggers to be expensive and inconvenient for infrasound campaigns, and developed the Gem infrasound logger in response. In this article, we discuss development of this infrasound logger and the various uses found for it, including projects on volcanoes, high-altitude balloons, and rivers. Further, we demonstrate that when needed, scientists can feasibly design and build their own specialized instruments, and that doing so can enable them to record more and better data at a lower cost.« less

  2. The Gem Infrasound Logger and Custom-Built Instrumentation

    DOE PAGES

    Anderson, Jacob F.; Johnson, Jeffrey B.; Bowman, Daniel C.; ...

    2017-11-22

    Here, we designed, built, and recorded data with a custom infrasound logger (referred to as the Gem) that is inexpensive, portable, and easy to use. We also describe its design process, qualities, and applications in this article. Field instrumentation is a key element of geophysical data collection, and the quantity and quality of data that can be recorded is determined largely by the characteristics of the instruments used. Geophysicists tend to rely on commercially available instruments, which suffice for many important types of fieldwork. However, commercial instrumentation can fall short in certain roles, which motivates the development of custom sensorsmore » and data loggers. Particularly, we found existing data loggers to be expensive and inconvenient for infrasound campaigns, and developed the Gem infrasound logger in response. In this article, we discuss development of this infrasound logger and the various uses found for it, including projects on volcanoes, high-altitude balloons, and rivers. Further, we demonstrate that when needed, scientists can feasibly design and build their own specialized instruments, and that doing so can enable them to record more and better data at a lower cost.« less

  3. Advanced Aerobots for Scientific Exploration

    NASA Technical Reports Server (NTRS)

    Behar, Alberto; Raymond, Carol A.; Matthews, Janet B.; Nicaise, Fabien; Jones, Jack A.

    2010-01-01

    The Picosat and Uninhabited Aerial Vehicle Systems Engineering (PAUSE) project is developing balloon-borne instrumentation systems as aerobots for scientific exploration of remote planets and for diverse terrestrial purposes that can include scientific exploration, mapping, and military surveillance. The underlying concept of balloon-borne gondolas housing outer-space-qualified scientific instruments and associated data-processing and radio-communication equipment is not new. Instead, the novelty lies in numerous design details that, taken together, make a PAUSE aerobot smaller, less expensive, and less massive, relative to prior aerobots developed for similar purposes: Whereas the gondola (including the instrumentation system housed in it) of a typical prior aerobot has a mass of hundreds of kilograms, the mass of the gondola (with instrumentation system) of a PAUSE aerobot is a few kilograms.

  4. Extending ORAC-DR for Offline Processing of ESO, INGRID, and Classic Cam data

    NASA Astrophysics Data System (ADS)

    Currie, M. J.

    2004-07-01

    ORAC-DR--a flexible reduction pipeline---was originally developed by the Joint Astronomy Centre for real-time inspection of reduced data at its telescopes. Starlink is extending ORAC-DR to process at home institutions data from other observatories, notably ESO, whose instruments make no provision for ORAC-DR. I outline the problems encountered and solutions implemented or proposed to apply ORAC-DR to the infra-red instruments ISAAC, NACO, INGRID, and Classic~Cam.

  5. Beam Instrument Development System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DOOLITTLE, LAWRENCE; HUANG, GANG; DU, QIANG

    Beam Instrumentation Development System (BIDS) is a collection of common support libraries and modules developed during a series of Low-Level Radio Frequency (LLRF) control and timing/synchronization projects. BIDS includes a collection of Hardware Description Language (HDL) libraries and software libraries. The BIDS can be used for the development of any FPGA-based system, such as LLRF controllers. HDL code in this library is generic and supports common Digital Signal Processing (DSP) functions, FPGA-specific drivers (high-speed serial link wrappers, clock generation, etc.), ADC/DAC drivers, Ethernet MAC implementation, etc.

  6. The development of a clinical outcomes survey research application: Assessment Center.

    PubMed

    Gershon, Richard; Rothrock, Nan E; Hanrahan, Rachel T; Jansky, Liz J; Harniss, Mark; Riley, William

    2010-06-01

    The National Institutes of Health sponsored Patient-Reported Outcome Measurement Information System (PROMIS) aimed to create item banks and computerized adaptive tests (CATs) across multiple domains for individuals with a range of chronic diseases. Web-based software was created to enable a researcher to create study-specific Websites that could administer PROMIS CATs and other instruments to research participants or clinical samples. This paper outlines the process used to develop a user-friendly, free, Web-based resource (Assessment Center) for storage, retrieval, organization, sharing, and administration of patient-reported outcomes (PRO) instruments. Joint Application Design (JAD) sessions were conducted with representatives from numerous institutions in order to supply a general wish list of features. Use Cases were then written to ensure that end user expectations matched programmer specifications. Program development included daily programmer "scrum" sessions, weekly Usability Acceptability Testing (UAT) and continuous Quality Assurance (QA) activities pre- and post-release. Assessment Center includes features that promote instrument development including item histories, data management, and storage of statistical analysis results. This case study of software development highlights the collection and incorporation of user input throughout the development process. Potential future applications of Assessment Center in clinical research are discussed.

  7. Fiber optic interferometry for industrial process monitoring and control applications

    NASA Astrophysics Data System (ADS)

    Marcus, Michael A.

    2002-02-01

    Over the past few years we have been developing applications for a high-resolution (sub-micron accuracy) fiber optic coupled dual Michelson interferometer-based instrument. It is being utilized in a variety of applications including monitoring liquid layer thickness uniformity on coating hoppers, film base thickness uniformity measurement, digital camera focus assessment, optical cell path length assessment and imager and wafer surface profile mapping. The instrument includes both coherent and non-coherent light sources, custom application dependent optical probes and sample interfaces, a Michelson interferometer, custom electronics, a Pentium-based PC with data acquisition cards and LabWindows CVI or LabView based application specific software. This paper describes the development evolution of this instrument platform and applications highlighting robust instrument design, hardware, software, and user interfaces development. The talk concludes with a discussion of a new high-speed instrument configuration, which can be utilized for high speed surface profiling and as an on-line web thickness gauge.

  8. Framework for the Integration of Multi-Instrument Pipelines in the BepiColombo Science Operations Control System

    NASA Astrophysics Data System (ADS)

    Pérez-López, F.; Vallejo, J. C.; Martínez, S.; Ortiz, I.; Macfarlane, A.; Osuna, P.; Gill, R.; Casale, M.

    2015-09-01

    BepiColombo is an interdisciplinary ESA mission to explore the planet Mercury in cooperation with JAXA. The mission consists of two separate orbiters: ESA's Mercury Planetary Orbiter (MPO) and JAXA's Mercury Magnetospheric Orbiter (MMO), which are dedicated to the detailed study of the planet and its magnetosphere. The MPO scientific payload comprises eleven instruments packages covering different disciplines developed by several European teams. This paper describes the design and development approach of the framework required to support the operation of the distributed BepiColombo MPO instruments pipelines, developed and operated from different locations, but designed as a single entity. An architecture based on primary-redundant configuration, fully integrated into the BepiColombo Science Operations Control System (BSCS), has been selected, where some instrument pipelines will be operated from the instrument team's data processing centres, having a pipeline replica that can be run from the Science Ground Segment (SGS), while others will be executed as primary pipelines from the SGS, adopting the SGS the pipeline orchestration role.

  9. Development of a Goal Setting Process and Instrumentation for Teachers and Principals.

    ERIC Educational Resources Information Center

    Minix, Nancy; And Others

    A pilot program, the Career Ladder Plan, was developed in Kentucky to evaluate a teacher's performance in terms of professional growth and development and professional leadership/initiative based on that teacher's performance on a setting/goal attainment process. Goals jointly selected by the teacher and his/her principal must contribute to school…

  10. Significant achievements in the planetary geology program

    NASA Technical Reports Server (NTRS)

    Head, J. W. (Editor)

    1984-01-01

    Recent developments in planetology research are summarized. Important developments are summarized in topics ranging from solar system evolution, comparative planetology, and geologic processes active on other planetary bodies, to techniques and instrument development for exploration.

  11. The quality of instruments to assess the process of shared decision making: A systematic review

    PubMed Central

    Bomhof-Roordink, Hanna; Smith, Ian P.; Scholl, Isabelle; Stiggelbout, Anne M.; Pieterse, Arwen H.

    2018-01-01

    Objective To inventory instruments assessing the process of shared decision making and appraise their measurement quality, taking into account the methodological quality of their validation studies. Methods In a systematic review we searched seven databases (PubMed, Embase, Emcare, Cochrane, PsycINFO, Web of Science, Academic Search Premier) for studies investigating instruments measuring the process of shared decision making. Per identified instrument, we assessed the level of evidence separately for 10 measurement properties following a three-step procedure: 1) appraisal of the methodological quality using the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist, 2) appraisal of the psychometric quality of the measurement property using three possible quality scores, 3) best-evidence synthesis based on the number of studies, their methodological and psychometrical quality, and the direction and consistency of the results. The study protocol was registered at PROSPERO: CRD42015023397. Results We included 51 articles describing the development and/or evaluation of 40 shared decision-making process instruments: 16 patient questionnaires, 4 provider questionnaires, 18 coding schemes and 2 instruments measuring multiple perspectives. There is an overall lack of evidence for their measurement quality, either because validation is missing or methods are poor. The best-evidence synthesis indicated positive results for a major part of instruments for content validity (50%) and structural validity (53%) if these were evaluated, but negative results for a major part of instruments when inter-rater reliability (47%) and hypotheses testing (59%) were evaluated. Conclusions Due to the lack of evidence on measurement quality, the choice for the most appropriate instrument can best be based on the instrument’s content and characteristics such as the perspective that they assess. We recommend refinement and validation of existing instruments, and the use of COSMIN-guidelines to help guarantee high-quality evaluations. PMID:29447193

  12. Development and Validation of the Homeostasis Concept Inventory

    ERIC Educational Resources Information Center

    McFarland, Jenny L.; Price, Rebecca M.; Wenderoth, Mary Pat; Martinková, Patrícia; Cliff, William; Michael, Joel; Modell, Harold; Wright, Ann

    2017-01-01

    We present the Homeostasis Concept Inventory (HCI), a 20-item multiple-choice instrument that assesses how well undergraduates understand this critical physiological concept. We used an iterative process to develop a set of questions based on elements in the Homeostasis Concept Framework. This process involved faculty experts and undergraduate…

  13. An Inclusive Process for Departmental Textbook Selection

    ERIC Educational Resources Information Center

    Altman, William S.; Ericksen, Kristen; Pena-Shaff, Judith B.

    2006-01-01

    This article reports on the development and use of an inclusive process to select a departmental textbook for general psychology. It describes a method for developing department-specific instruments to narrow the available textbook choices and an in-class textbook trial used in the final selection. Reported advantages of this method include…

  14. The Development of a Plan for the Assessment, Improvement and Deployment of a Radar Acoustic Sounding System (RASS) for Wake Vortex Detection

    NASA Technical Reports Server (NTRS)

    Morris, Philip J.; McLaughlin, Dennis K.; Gabrielson, Thomas B.; Boluriaan, Said

    2004-01-01

    This report describes the activities completed under a grant from the NASA Langley Research Center to develop a plan for the assessment, improvement, and deployment of a Radar Acoustic Sounding System (RASS) for the detection of wake vortices. A brief review is provided of existing alternative instruments for wake vortex detection. This is followed by a review of previous implementations and assessment of a RASS. As a result of this review, it is concluded that the basic features of a RASS have several advantages over other commonly used wake vortex detection and measurement systems. Most important of these features are the good fidelity of the measurements and the potential for all weather operation. To realize the full potential of this remote sensing instrument, a plan for the development of a RASS designed specifically for wake vortex detection and measurement has been prepared. To keep costs to a minimum, this program would start with the development an inexpensive laboratory-scale version of a RASS system. The new instrument would be developed in several stages, each allowing for a critical assessment of the instrument s potential and limitations. The instrument, in its initial stages of development, would be tested in a controlled laboratory environment. A jet vortex simulator, a prototype version of which has already been fabricated, would be interrogated by the RASS system. The details of the laboratory vortex would be measured using a Particle Image Velocimetry (PIV) system. In the early development stages, the scattered radar signal would be digitized and the signal post-processed to determine how extensively and accurately the RASS could measure properties of the wake vortex. If the initial tests prove to be successful, a real-time, digital signal processing system would be developed as a component of the RASS system. At each stage of the instrument development and testing, the implications of the scaling required for a full-scale instrument would be considered. It is concluded that a RASS system, developed for the specific application of wake vortex detection, could become part of a robust Aircraft Vortex Spacing System (AVOSS). This system, in turn, could contribute to Reduced Spacing Operations (RSO) in US airports and improvements in Terminal Area productivity (TAP).

  15. Development and Current Status of Skull-Image Superimposition - Methodology and Instrumentation.

    PubMed

    Lan, Y

    1992-12-01

    This article presents a review of the literature and an evaluation on the development and application of skull-image superimposition technology - both instrumentation and methodology - contributed by a number of scholars since 1935. Along with a comparison of the methodologies involved in the two superimposition techniques - photographic and video - the author characterized the techniques in action and the recent advances in computer image superimposition processing technology. The major disadvantage of conventional approaches is its relying on subjective interpretation. Through painstaking comparison and analysis, computer image processing technology can make more conclusive identifications by direct testing and evaluating the various programmed indices. Copyright © 1992 Central Police University.

  16. Compact solar autoclave based on steam generation using broadband light-harvesting nanoparticles

    PubMed Central

    Neumann, Oara; Feronti, Curtis; Neumann, Albert D.; Dong, Anjie; Schell, Kevin; Lu, Benjamin; Kim, Eric; Quinn, Mary; Thompson, Shea; Grady, Nathaniel; Nordlander, Peter; Oden, Maria; Halas, Naomi J.

    2013-01-01

    The lack of readily available sterilization processes for medicine and dentistry practices in the developing world is a major risk factor for the propagation of disease. Modern medical facilities in the developed world often use autoclave systems to sterilize medical instruments and equipment and process waste that could contain harmful contagions. Here, we show the use of broadband light-absorbing nanoparticles as solar photothermal heaters, which generate high-temperature steam for a standalone, efficient solar autoclave useful for sanitation of instruments or materials in resource-limited, remote locations. Sterilization was verified using a standard Geobacillus stearothermophilus-based biological indicator. PMID:23836642

  17. Development and psychometric evaluation of the Primary Health Care Engagement (PHCE) Scale: a pilot survey of rural and remote nurses.

    PubMed

    Kosteniuk, Julie G; Wilson, Erin C; Penz, Kelly L; MacLeod, Martha L P; Stewart, Norma J; Kulig, Judith C; Karunanayake, Chandima P; Kilpatrick, Kelley

    2016-01-01

    To report the development and psychometric evaluation of a scale to measure rural and remote (rural/remote) nurses' perceptions of the engagement of their workplaces in key dimensions of primary health care (PHC). Amidst ongoing PHC reforms, a comprehensive instrument is needed to evaluate the degree to which rural/remote health care settings are involved in the key dimensions that characterize PHC delivery, particularly from the perspective of professionals delivering care. This study followed a three-phase process of instrument development and psychometric evaluation. A literature review and expert consultation informed instrument development in the first phase, followed by an iterative process of content evaluation in the second phase. In the final phase, a pilot survey was undertaken and item discrimination analysis employed to evaluate the internal consistency reliability of each subscale in the preliminary 60-item Primary Health Care Engagement (PHCE) Scale. The 60-item scale was subsequently refined to a 40-item instrument. The pilot survey sample included 89 nurses in current practice who had experience in rural/remote practice settings. Participants completed either a web-based or paper survey from September to December, 2013. Following item discrimination analysis, the 60-item instrument was refined to a 40-item PHCE Scale consisting of 10 subscales, each including three to five items. Alpha estimates of the 10 refined subscales ranged from 0.61 to 0.83, with seven of the subscales demonstrating acceptable reliability (α ⩾ 0.70). The refined 40-item instrument exhibited good internal consistency reliability (α=0.91). The 40-item PHCE Scale may be considered for use in future studies regardless of locale, to measure the extent to which health care professionals perceive their workplaces to be engaged in key dimensions of PHC.

  18. The instrumental genesis process in future primary teachers using Dynamic Geometry Software

    NASA Astrophysics Data System (ADS)

    Ruiz-López, Natalia

    2018-05-01

    This paper, which describes a study undertaken with pairs of future primary teachers using GeoGebra software to solve geometry problems, includes a brief literature review, the theoretical framework and methodology used. An analysis of the instrumental genesis process for a pair participating in the case study is also provided. This analysis addresses the techniques and types of dragging used, the obstacles to learning encountered, a description of the interaction between the pair and their interaction with the teacher, and the type of language used. Based on this analysis, possibilities and limitations of the instrumental genesis process are identified for the development of geometric competencies such as conjecture creation, property checking and problem researching. It is also suggested that the methodology used in the analysis of the problem solving process may be useful for those teachers and researchers who want to integrate Dynamic Geometry Software (DGS) in their classrooms.

  19. Optical surface analysis: a new technique for the inspection and metrology of optoelectronic films and wafers

    NASA Astrophysics Data System (ADS)

    Bechtler, Laurie; Velidandla, Vamsi

    2003-04-01

    In response to demand for higher volumes and greater product capability, integrated optoelectronic device processing is rapidly increasing in complexity, benefiting from techniques developed for conventional silicon integrated circuit processing. The needs for high product yield and low manufacturing cost are also similar to the silicon wafer processing industry. This paper discusses the design and use of an automated inspection instrument called the Optical Surface Analyzer (OSA) to evaluate two critical production issues in optoelectronic device manufacturing: (1) film thickness uniformity, and (2) defectivity at various process steps. The OSA measurement instrument is better suited to photonics process development than most equipment developed for conventional silicon wafer processing in two important ways: it can handle both transparent and opaque substrates (unlike most inspection and metrology tools), and it is a full-wafer inspection method that captures defects and film variations over the entire substrate surface (unlike most film thickness measurement tools). Measurement examples will be provided in the paper for a variety of films and substrates used for optoelectronics manufacturing.

  20. Outcomes of Moral Case Deliberation - the development of an evaluation instrument for clinical ethics support (the Euro-MCD)

    PubMed Central

    2014-01-01

    Background Clinical ethics support, in particular Moral Case Deliberation, aims to support health care providers to manage ethically difficult situations. However, there is a lack of evaluation instruments regarding outcomes of clinical ethics support in general and regarding Moral Case Deliberation (MCD) in particular. There also is a lack of clarity and consensuses regarding which MCD outcomes are beneficial. In addition, MCD outcomes might be context-sensitive. Against this background, there is a need for a standardised but flexible outcome evaluation instrument. The aim of this study was to develop a multi-contextual evaluation instrument measuring health care providers’ experiences and perceived importance of outcomes of Moral Case Deliberation. Methods A multi-item instrument for assessing outcomes of Moral Case Deliberation (MCD) was constructed through an iterative process, founded on a literature review and modified through a multistep review by ethicists and health care providers. The instrument measures perceived importance of outcomes before and after MCD, as well as experienced outcomes during MCD and in daily work. A purposeful sample of 86 European participants contributed to a Delphi panel and content validity testing. The Delphi panel (n = 13), consisting of ethicists and ethics researchers, participated in three Delphi-rounds. Health care providers (n = 73) participated in the content validity testing through ‘think-aloud’ interviews and a method using Content Validity Index. Results The development process resulted in the European Moral Case Deliberation Outcomes Instrument (Euro-MCD), which consists of two sections, one to be completed before a participant’s first MCD and the other after completing multiple MCDs. The instrument contains a few open-ended questions and 26 specific items with a corresponding rating/response scale representing various MCD outcomes. The items were categorised into the following six domains: Enhanced emotional support, Enhanced collaboration, Improved moral reflexivity, Improved moral attitude, Improvement on organizational level and Concrete results. Conclusions A tentative instrument has been developed that seems to cover main outcomes of Moral Case Deliberation. The next step will be to test the Euro-MCD in a field study. PMID:24712735

  1. Outcomes of moral case deliberation--the development of an evaluation instrument for clinical ethics support (the Euro-MCD).

    PubMed

    Svantesson, Mia; Karlsson, Jan; Boitte, Pierre; Schildman, Jan; Dauwerse, Linda; Widdershoven, Guy; Pedersen, Reidar; Huisman, Martijn; Molewijk, Bert

    2014-04-08

    Clinical ethics support, in particular Moral Case Deliberation, aims to support health care providers to manage ethically difficult situations. However, there is a lack of evaluation instruments regarding outcomes of clinical ethics support in general and regarding Moral Case Deliberation (MCD) in particular. There also is a lack of clarity and consensuses regarding which MCD outcomes are beneficial. In addition, MCD outcomes might be context-sensitive. Against this background, there is a need for a standardised but flexible outcome evaluation instrument. The aim of this study was to develop a multi-contextual evaluation instrument measuring health care providers' experiences and perceived importance of outcomes of Moral Case Deliberation. A multi-item instrument for assessing outcomes of Moral Case Deliberation (MCD) was constructed through an iterative process, founded on a literature review and modified through a multistep review by ethicists and health care providers. The instrument measures perceived importance of outcomes before and after MCD, as well as experienced outcomes during MCD and in daily work. A purposeful sample of 86 European participants contributed to a Delphi panel and content validity testing. The Delphi panel (n = 13), consisting of ethicists and ethics researchers, participated in three Delphi-rounds. Health care providers (n = 73) participated in the content validity testing through 'think-aloud' interviews and a method using Content Validity Index. The development process resulted in the European Moral Case Deliberation Outcomes Instrument (Euro-MCD), which consists of two sections, one to be completed before a participant's first MCD and the other after completing multiple MCDs. The instrument contains a few open-ended questions and 26 specific items with a corresponding rating/response scale representing various MCD outcomes. The items were categorised into the following six domains: Enhanced emotional support, Enhanced collaboration, Improved moral reflexivity, Improved moral attitude, Improvement on organizational level and Concrete results. A tentative instrument has been developed that seems to cover main outcomes of Moral Case Deliberation. The next step will be to test the Euro-MCD in a field study.

  2. Artificial intelligence programming with LabVIEW: genetic algorithms for instrumentation control and optimization.

    PubMed

    Moore, J H

    1995-06-01

    A genetic algorithm for instrumentation control and optimization was developed using the LabVIEW graphical programming environment. The usefulness of this methodology for the optimization of a closed loop control instrument is demonstrated with minimal complexity and the programming is presented in detail to facilitate its adaptation to other LabVIEW applications. Closed loop control instruments have variety of applications in the biomedical sciences including the regulation of physiological processes such as blood pressure. The program presented here should provide a useful starting point for those wishing to incorporate genetic algorithm approaches to LabVIEW mediated optimization of closed loop control instruments.

  3. 3D tracking of laparoscopic instruments using statistical and geometric modeling.

    PubMed

    Wolf, Rémi; Duchateau, Josselin; Cinquin, Philippe; Voros, Sandrine

    2011-01-01

    During a laparoscopic surgery, the endoscope can be manipulated by an assistant or a robot. Several teams have worked on the tracking of surgical instruments, based on methods ranging from the development of specific devices to image processing methods. We propose to exploit the instruments' insertion points, which are fixed on the patients abdominal cavity, as a geometric constraint for the localization of the instruments. A simple geometric model of a laparoscopic instrument is described, as well as a parametrization that exploits a spherical geometric grid, which offers attracting homogeneity and isotropy properties. The general architecture of our proposed approach is based on the probabilistic Condensation algorithm.

  4. Design and Development of a Miniaturized Double Latching Solenoid Valve for the Sample Analysis at Mars Instrument Suite

    NASA Technical Reports Server (NTRS)

    Smith, James T.

    2008-01-01

    The development of the in-house Miniaturized Double Latching Solenoid Valve, or Microvalve, for the Gas Processing System (GPS) of the Sample Analysis at Mars (SAM) instrument suite is described. The Microvalve is a double latching solenoid valve that actuates a pintle shaft axially to hermetically seal an orifice. The key requirements and the design innovations implemented to meet them are described.

  5. Adaptive Instrument Module: Space Instrument Controller "Brain" through Programmable Logic Devices

    NASA Technical Reports Server (NTRS)

    Darrin, Ann Garrison; Conde, Richard; Chern, Bobbie; Luers, Phil; Jurczyk, Steve; Mills, Carl; Day, John H. (Technical Monitor)

    2001-01-01

    The Adaptive Instrument Module (AIM) will be the first true demonstration of reconfigurable computing with field-programmable gate arrays (FPGAs) in space, enabling the 'brain' of the system to evolve or adapt to changing requirements. In partnership with NASA Goddard Space Flight Center and the Australian Cooperative Research Centre for Satellite Systems (CRC-SS), APL has built the flight version to be flown on the Australian university-class satellite FEDSAT. The AIM provides satellites the flexibility to adapt to changing mission requirements by reconfiguring standardized processing hardware rather than incurring the large costs associated with new builds. This ability to reconfigure the processing in response to changing mission needs leads to true evolveable computing, wherein the instrument 'brain' can learn from new science data in order to perform state-of-the-art data processing. The development of the AIM is significant in its enormous potential to reduce total life-cycle costs for future space exploration missions. The advent of RAM-based FPGAs whose configuration can be changed at any time has enabled the development of the AIM for processing tasks that could not be performed in software. The use of the AIM enables reconfiguration of the FPGA circuitry while the spacecraft is in flight, with many accompanying advantages. The AIM demonstrates the practicalities of using reconfigurable computing hardware devices by conducting a series of designed experiments. These include the demonstration of implementing data compression, data filtering, and communication message processing and inter-experiment data computation. The second generation is the Adaptive Processing Template (ADAPT) which is further described in this paper. The next step forward is to make the hardware itself adaptable and the ADAPT pursues this challenge by developing a reconfigurable module that will be capable of functioning efficiently in various applications. ADAPT will take advantage of radiation tolerant RAM-based field programmable gate array (FPGA) technology to develop a reconfigurable processor that combines the flexibility of a general purpose processor running software with the performance of application specific processing hardware for a variety of high performance computing applications.

  6. High Data Rate Instrument Study

    NASA Technical Reports Server (NTRS)

    Schober, Wayne; Lansing, Faiza; Wilson, Keith; Webb, Evan

    1999-01-01

    The High Data Rate Instrument Study was a joint effort between the Jet Propulsion Laboratory (JPL) and the Goddard Space Flight Center (GSFC). The objectives were to assess the characteristics of future high data rate Earth observing science instruments and then to assess the feasibility of developing data processing systems and communications systems required to meet those data rates. Instruments and technology were assessed for technology readiness dates of 2000, 2003, and 2006. The highest data rate instruments are hyperspectral and synthetic aperture radar instruments which are capable of generating 3.2 Gigabits per second (Gbps) and 1.3 Gbps, respectively, with a technology readiness date of 2003. These instruments would require storage of 16.2 Terebits (Tb) of information (RF communications case of two orbits of data) or 40.5 Tb of information (optical communications case of five orbits of data) with a technology readiness date of 2003. Onboard storage capability in 2003 is estimated at 4 Tb; therefore, all the data created cannot be stored without processing or compression. Of the 4 Tb of stored data, RF communications can only send about one third of the data to the ground, while optical communications is estimated at 6.4 Tb across all three technology readiness dates of 2000, 2003, and 2006 which were used in the study. The study includes analysis of the onboard processing and communications technologies at these three dates and potential systems to meet the high data rate requirements. In the 2003 case, 7.8% of the data can be stored and downlinked by RF communications while 10% of the data can be stored and downlinked with optical communications. The study conclusion is that only 1 to 10% of the data generated by high data rate instruments will be sent to the ground from now through 2006 unless revolutionary changes in spacecraft design and operations such as intelligent data extraction are developed.

  7. Integrated micro-electro-mechanical sensor development for inertial applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, J.J.; Kinney, R.D.; Sarsfield, J.

    Electronic sensing circuitry and micro electro mechanical sense elements can be integrated to produce inertial instruments for applications unheard of a few years ago. This paper will describe the Sandia M3EMS fabrication process, inertial instruments that have been fabricated, and the results of initial characterization tests of micro-machined accelerometers.

  8. Space Shuttle Orbiter Main Engine Ignition Acoustic Pressure Loads Issue: Recent Actions to Install Wireless Instrumentation on STS-129

    NASA Technical Reports Server (NTRS)

    Wells, Nathan; Studor, George

    2009-01-01

    This slide presentation reviews the development and construction of the wireless acoustic instruments surrounding the space shuttle's main engines in preparation for STS-129. The presentation also includes information on end-of-life processing and the mounting procedure for the devices.

  9. Measurement in the Service of Mathematics Education Research: The Case of Cognitively Guided Instruction

    ERIC Educational Resources Information Center

    Helding, Brandon Alan

    2010-01-01

    The purpose of this dissertation is to demonstrate one iterate of a process for developing a measurement instrument for student knowledge within educational interventions. Student mathematical knowledge is framed within Cognitively Guided Instruction (CGI) and its tenets. That is, the construct underlying the measurement instrument corresponded…

  10. Maintaining Motivation and Regulating Emotion: Measuring Individual Differences in Academic Volitional Strategies.

    ERIC Educational Resources Information Center

    McCann, Erin J.; Garcia, Teresa

    An instrument was developed to measure the resourcefulness and self-directedness of students in maintaining their motivation on academic goal tasks. The Academic Volitional Strategy Inventory (AVSI) is a self-report instrument designed to assess the management of emotion and motivation by college students during the goal-striving process. An…

  11. Is the Environmental Literacy of University Students Measurable?

    ERIC Educational Resources Information Center

    Shephard, Kerry; Harraway, John; Lovelock, Brent; Skeaff, Sheila; Slooten, Liz; Strack, Mick; Furnari, Mary; Jowett, Tim

    2014-01-01

    We report the development and piloting of an evaluative instrument and process for monitoring the environmental literacy (EL) of undergraduate students in one large research-led university in New Zealand. The instrument addresses knowledge, affect and competencies in the general area of EL in line with this institution's adoption of EL as a…

  12. Assessment for One-Shot Library Instruction: A Conceptual Approach

    ERIC Educational Resources Information Center

    Wang, Rui

    2016-01-01

    The purpose of this study is to explore a conceptual approach to assessment for one-shot library instruction. This study develops a new assessment instrument based on Carol Kuhlthau's information search process (ISP) model. The new instrument focuses on measuring and identifying changes in student readiness to do research along three…

  13. Techniques for Embedding Instrumentation in Pressure Vessel Test Articles

    NASA Technical Reports Server (NTRS)

    Cornelius, Michael

    2006-01-01

    Many interesting structural and thermal events occur in materials that are housed within a surrounding pressure vessel. In order to measure the environment during these events and explore their causes instrumentation must be installed on or in the material. Transducers can be selected that are small enough to be embedded within the test material but these instruments must interface with an external system in order to apply excitation voltages and output the desired data. The methods for installing the instrumentation and creating an interface are complicated when the material is located in a case or housing containing high pressures and hot gases. Installation techniques for overcoming some of these difficulties were developed while testing a series of small-scale solid propellant and hybrid rocket motors at Marshall Space Flight Center. These techniques have potential applications in other test articles where data are acquired from materials that require containment due to the severe environment encountered during the test process. This severe environment could include high pressure, hot gases, or ionized atmospheres. The development of these techniques, problems encountered, and the lessons learned from the ongoing testing process are summarized.

  14. Using XML and Java for Astronomical Instrumentation Control

    NASA Technical Reports Server (NTRS)

    Ames, Troy; Koons, Lisa; Sall, Ken; Warsaw, Craig

    2000-01-01

    Traditionally, instrument command and control systems have been highly specialized, consisting mostly of custom code that is difficult to develop, maintain, and extend. Such solutions are initially very costly and are inflexible to subsequent engineering change requests, increasing software maintenance costs. Instrument description is too tightly coupled with details of implementation. NASA Goddard Space Flight Center is developing a general and highly extensible framework that applies to any kind of instrument that can be controlled by a computer. The software architecture combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML), a human readable and machine understandable way to describe structured data. A key aspect of the object-oriented architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). ]ML is used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, and communication mechanisms. Although the current effort is targeted for the High-resolution Airborne Wideband Camera, a first-light instrument of the Stratospheric Observatory for Infrared Astronomy, the framework is designed to be generic and extensible so that it can be applied to any instrument.

  15. Development of an embedded instrument for autofocus and polarization alignment of polarization maintaining fiber

    NASA Astrophysics Data System (ADS)

    Feng, Di; Fang, Qimeng; Huang, Huaibo; Zhao, Zhengqi; Song, Ningfang

    2017-12-01

    The development and implementation of a practical instrument based on an embedded technique for autofocus and polarization alignment of polarization maintaining fiber is presented. For focusing efficiency and stability, an image-based focusing algorithm fully considering the image definition evaluation and the focusing search strategy was used to accomplish autofocus. For improving the alignment accuracy, various image-based algorithms of alignment detection were developed with high calculation speed and strong robustness. The instrument can be operated as a standalone device with real-time processing and convenience operations. The hardware construction, software interface, and image-based algorithms of main modules are described. Additionally, several image simulation experiments were also carried out to analyze the accuracy of the above alignment detection algorithms. Both the simulation results and experiment results indicate that the instrument can achieve the accuracy of polarization alignment <±0.1 deg.

  16. The risk concept and its application in natural hazard risk management in Switzerland

    NASA Astrophysics Data System (ADS)

    Bründl, M.; Romang, H. E.; Bischof, N.; Rheinberger, C. M.

    2009-05-01

    Over the last ten years, a risk-based approach to manage natural hazards - termed the risk concept - has been introduced to the management of natural hazards in Switzerland. Large natural hazard events, new political initiatives and limited financial resources have led to the development and introduction of new planning instruments and software tools that should support natural hazard engineers and planners to effectively and efficiently deal with natural hazards. Our experience with these new instruments suggests an improved integration of the risk concept into the community of natural hazard engineers and planners. Important factors for the acceptance of these new instruments are the integration of end-users during the development process, the knowledge exchange between science, developers and end-users as well as training and education courses for users. Further improvements require the maintenance of this knowledge exchange and a mindful adaptation of the instruments to case-specific circumstances.

  17. Initial Navigation Alignment of Optical Instruments on GOES-R

    NASA Astrophysics Data System (ADS)

    Isaacson, P.; DeLuccia, F.; Reth, A. D.; Igli, D. A.; Carter, D.

    2016-12-01

    The GOES-R satellite is the first in NOAA's next-generation series of geostationary weather satellites. In addition to a number of space weather sensors, it will carry two principal optical earth-observing instruments, the Advanced Baseline Imager (ABI) and the Geostationary Lightning Mapper (GLM). During launch, currently scheduled for November of 2016, the alignment of these optical instruments is anticipated to shift from that measured during pre-launch characterization. While both instruments have image navigation and registration (INR) processing algorithms to enable automated geolocation of the collected data, the launch-derived misalignment may be too large for these approaches to function without an initial adjustment to calibration parameters. The parameters that may require adjustment are for Line of Sight Motion Compensation (LMC), and the adjustments will be estimated on orbit during the post-launch test (PLT) phase. We have developed approaches to estimate the initial alignment errors for both ABI and GLM image products. Our approaches involve comparison of ABI and GLM images collected during PLT to a set of reference ("truth") images using custom image processing tools and other software (the INR Performance Assessment Tool Set, or "IPATS") being developed for other INR assessments of ABI and GLM data. IPATS is based on image correlation approaches to determine offsets between input and reference images, and these offsets are the fundamental input to our estimate of the initial alignment errors. Initial testing of our alignment algorithms on proxy datasets lends high confidence that their application will determine the initial alignment errors to within sufficient accuracy to enable the operational INR processing approaches to proceed in a nominal fashion. We will report on the algorithms, implementation approach, and status of these initial alignment tools being developed for the GOES-R ABI and GLM instruments.

  18. Design and validation of the INICIARE instrument, for the assessment of dependency level in acutely ill hospitalised patients.

    PubMed

    Morales-Asencio, José Miguel; Porcel-Gálvez, Ana María; Oliveros-Valenzuela, Rosa; Rodríguez-Gómez, Susana; Sánchez-Extremera, Lucrecia; Serrano-López, Francisco Andrés; Aranda-Gallardo, Marta; Canca-Sánchez, José Carlos; Barrientos-Trigo, Sergio

    2015-03-01

    The aim of this study was to establish the validity and reliability of an instrument (Inventario del NIvel de Cuidados mediante IndicAdores de clasificación de Resultados de Enfermería) used to assess the dependency level in acutely hospitalised patients. This instrument is novel, and it is based on the Nursing Outcomes Classification. Multiple existing instruments for needs assessment have been poorly validated and based predominately on interventions. Standardised Nursing Languages offer an ideal framework to develop nursing sensitive instruments. A cross-sectional validation study in two acute care hospitals in Spain. This study was implemented in two phases. First, the research team developed the instrument to be validated. In the second phase, the validation process was performed by experts, and the data analysis was conducted to establish the psychometric properties of the instrument. Seven hundred and sixty-one patient ratings performed by nurses were collected during the course of the research study. Data analysis yielded a Cronbach's alpha of 0·91. An exploratory factorial analysis identified three factors (Physiological, Instrumental and Cognitive-behavioural), which explained 74% of the variance. Inventario del NIvel de Cuidados mediante IndicAdores de clasificación de Resultados de Enfermería was demonstrated to be a valid and reliable instrument based on its use in acutely hospitalised patients to assess the level of dependency. Inventario del NIvel de Cuidados mediante IndicAdores de clasificación de Resultados de Enfermería can be used as an assessment tool in hospitalised patients during the nursing process throughout the entire hospitalisation period. It contributes information to support decisions on nursing diagnoses, interventions and outcomes. It also enables data codification in large databases. © 2014 John Wiley & Sons Ltd.

  19. Development of the instruments for the Gamma Ray Observatory

    NASA Technical Reports Server (NTRS)

    Madden, J. J.; Kniffen, D. A.

    1986-01-01

    The Gamma Ray Observatory (GRO) is to be launched in 1988 by the STS. The GRO will feature four very large instruments: the Oriented Scintillation Spectrometer Experiment (OSSE), the Imaging Compton Telescope (COMPTEL), the Energetic Gamma Ray Experiment Telescope (EGRET) and the Burst and Transient Source Experiment (BATSE). The instruments weigh from 900-1200 kg each, and required the development of specialized lifting and dolly devices to permit their assembly, manipulation and testing. The GRO is intended a{s a tool for studying discrete celestial objects such as black holes, neutron stars and other gamma-ray emitting objects, scanning for nucleosynthesis processes, mapping the Galaxy and other, high energy galaxies in terms of gamma rays, searching for cosmological effects and observing gamma ray bursts. The instruments will be sensitive from the upper end mof X-rya wavelengths to the highest energies possible. Details of the hardware and performance specifications of each of the instruments are discussed.

  20. Thermal Vacuum Chamber Repressurization with Instrument Purging

    NASA Technical Reports Server (NTRS)

    Woronowicz, Michael

    2016-01-01

    At the end of James Webb Space Telescope (JWST) OTIS (Optical Telescope Element-OTE-Integrated Science Instrument Module-ISIM) cryogenic vacuum testing in NASA Johnson Space Centers (JSCs) thermal vacuum (TV) Chamber A, contamination control (CC) engineers are mooting the idea that chamber particulate material stirred up by the repressurization process may be kept from falling into the ISIM interior to some degree by activating instrument purge flows over some initial period before opening the chamber valves. This memo describes development of a series of models designed to describe this process. These are strung together in tandem to estimate overpressure evolution from which net outflow velocity behavior may be obtained. Creeping flow assumptions are then used to determine the maximum particle size that may be kept suspended above the ISIM aperture, keeping smaller particles from settling within the instrument module.

  1. Thermal Vacuum Chamber Repressurization with Instrument Purging

    NASA Technical Reports Server (NTRS)

    Woronowicz, Michael

    2017-01-01

    At the end of James Webb Space Telescope (JWST) OTIS (Optical Telescope Element-OTE-Integrated Science Instrument Module-ISIM) cryogenic vacuum testing in NASA Johnson Space Centers (JSCs) thermal vacuum (TV) Chamber A, contamination control (CC) engineers are mooting the idea that chamber particulate material stirred up by the repressurization process may be kept from falling into the ISIM interior to some degree by activating instrument purge flows over some initial period before opening the chamber valves. This memo describes development of a series of models designed to describe this process. These are strung together in tandem to estimate overpressure evolution from which net outflow velocity behavior may be obtained. Creeping flow assumptions are then used to determine the maximum particle size that may be kept suspended above the ISIM aperture, keeping smaller particles from settling within the instrument module.

  2. Principles of Space Plasma Wave Instrument Design

    NASA Technical Reports Server (NTRS)

    Gurnett, Donald A.

    1998-01-01

    Space plasma waves span the frequency range from somewhat below the ion cyclotron frequency to well above the electron cyclotron frequency and plasma frequency. Because of the large frequency range involved, the design of space plasma wave instrumentation presents many interesting challenges. This chapter discusses the principles of space plasma wave instrument design. The topics covered include: performance requirements, electric antennas, magnetic antennas, and signal processing. Where appropriate, comments are made on the likely direction of future developments.

  3. Advanced instrumentation for the collection, retrieval, and processing of urban stormwater data

    USGS Publications Warehouse

    Robinson, Jerald B.; Bales, Jerad D.; Young, Wendi S.; ,

    1995-01-01

    The U.S. Geological Survey, in cooperation with the City of Charlotte and Mecklenburg County, North Carolina, has developed a data-collection network that uses advanced instrumentation to automatically collect, retrieve, and process urban stormwater data. Precipitation measurement and water-quality networks provide data for (1) planned watershed simulation models, (2) early warning of possible flooding, (3) computation of material export, and (4) characterization of water quality in relation to basin conditions. Advantages of advanced instrumentation include remote access to real-time data, reduced demands on and more efficient use of limited human resources, and direct importation of data into a geographical information system for display and graphic analysis.

  4. Hydratools, a MATLAB® based data processing package for Sontek Hydra data

    USGS Publications Warehouse

    Martini, M.; Lightsom, F.L.; Sherwood, C.R.; Xu, Jie; Lacy, J.R.; Ramsey, A.; Horwitz, R.

    2005-01-01

    The U.S. Geological Survey (USGS) has developed a set of MATLAB tools to process and convert data collected by Sontek Hydra instruments to netCDF, which is a format used by the USGS to process and archive oceanographic time-series data. The USGS makes high-resolution current measurements within 1.5 meters of the bottom. These data are used in combination with other instrument data from sediment transport studies to develop sediment transport models. Instrument manufacturers provide software which outputs unique binary data formats. Multiple data formats are cumbersome. The USGS solution is to translate data streams into a common data format: netCDF. The Hydratools toolbox is written to create netCDF format files following EPIC conventions, complete with embedded metadata. Data are accepted from both the ADV and the PCADP. The toolbox will detect and remove bad data, substitute other sources of heading and tilt measurements if necessary, apply ambiguity corrections, calculate statistics, return information about data quality, and organize metadata. Standardized processing and archiving makes these data more easily and routinely accessible locally and over the Internet. In addition, documentation of the techniques used in the toolbox provides a baseline reference for others utilizing the data.

  5. Force sensing of multiple-DOF cable-driven instruments for minimally invasive robotic surgery.

    PubMed

    He, Chao; Wang, Shuxin; Sang, Hongqiang; Li, Jinhua; Zhang, Linan

    2014-09-01

    Force sensing for robotic surgery is limited by the size of the instrument, friction and sterilization requirements. This paper presents a force-sensing instrument to avoid these restrictions. Operating forces were calculated according to cable tension. Mathematical models of the force-sensing system were established. A force-sensing instrument was designed and fabricated. A signal collection and processing system was constructed. The presented approach can avoid the constraints of space limits, sterilization requirements and friction introduced by the transmission parts behind the instrument wrist. Test results showed that the developed instrument has a 0.03 N signal noise, a 0.05 N drift, a 0.04 N resolution and a maximum error of 0.4 N. The validation experiment indicated that the operating and grasping forces can be effectively sensed. The developed force-sensing system can be used in minimally invasive robotic surgery to construct a force-feedback system. Copyright © 2013 John Wiley & Sons, Ltd.

  6. Analysis of Six Reviews on the Quality of Instruments for the Evaluation of Interprofessional Education in German-Speaking Countries.

    PubMed

    Ehlers, Jan P; Kaap-Fröhlich, Sylvia; Mahler, Cornelia; Scherer, Theresa; Huber, Marion

    2017-01-01

    Background: More and more institutions worldwide and in German-speaking countries are developing and establishing interprofessional seminars in undergraduate education of health professions. In order to evaluate the different didactic approaches and different outcomes regarding the anticipated interprofessional competencies, it is necessary to apply appropriate instruments. Cross-cultural instruments are particularly helpful for international comparability. The Interprofessional Education working group of the German Medical Association (GMA) aims at identifying existing instruments for the evaluation of interprofessional education in order to make recommendations for German-speaking countries. Methods: Systematic literature research was performed on the websites of international interprofessional organisations (CAIPE, EIPEN, AIPEN), as well as in the PubMed and Cinahl databases. Reviews focusing on quantitative instruments to evaluate competencies according to the modified Kirkpatrick competency levels were searched for. Psychometrics, language/country and setting, in which the instrument was applied, were recorded. Results: Six reviews out of 73 literature research hits were included. A large number of instruments were identified; however, their psychometrics and the applied setting were very heterogeneous. The instruments can mainly be assigned to Kirkpatrick levels 1, 2a & 2b. Most instruments have been developed in English but their psychometrics were not always reported rigorously. Only very few instruments are available in German. Conclusion: It is difficult to find appropriate instruments in German. Internationally, there are different approaches and objectives in the measurement and evaluation of interprofessional competencies. The question arises whether it makes sense to translate existing instruments or to go through the lengthy process of developing new ones. The evaluation of interprofessional seminars with quantitative instruments remains mainly on Kirkpatrick levels 1 and 2. Levels 3 and 4 can probably only be assessed with qualitative or mixed methods. German language instruments are necessary.

  7. Analysis of Six Reviews on the Quality of Instruments for the Evaluation of Interprofessional Education in German-Speaking Countries

    PubMed Central

    Ehlers, Jan P.; Kaap-Fröhlich, Sylvia; Mahler, Cornelia; Scherer, Theresa; Huber, Marion

    2017-01-01

    Background: More and more institutions worldwide and in German-speaking countries are developing and establishing interprofessional seminars in undergraduate education of health professions. In order to evaluate the different didactic approaches and different outcomes regarding the anticipated interprofessional competencies, it is necessary to apply appropriate instruments. Cross-cultural instruments are particularly helpful for international comparability. The Interprofessional Education working group of the German Medical Association (GMA) aims at identifying existing instruments for the evaluation of interprofessional education in order to make recommendations for German-speaking countries. Methods: Systematic literature research was performed on the websites of international interprofessional organisations (CAIPE, EIPEN, AIPEN), as well as in the PubMed and Cinahl databases. Reviews focusing on quantitative instruments to evaluate competencies according to the modified Kirkpatrick competency levels were searched for. Psychometrics, language/country and setting, in which the instrument was applied, were recorded. Results: Six reviews out of 73 literature research hits were included. A large number of instruments were identified; however, their psychometrics and the applied setting were very heterogeneous. The instruments can mainly be assigned to Kirkpatrick levels 1, 2a & 2b. Most instruments have been developed in English but their psychometrics were not always reported rigorously. Only very few instruments are available in German. Conclusion: It is difficult to find appropriate instruments in German. Internationally, there are different approaches and objectives in the measurement and evaluation of interprofessional competencies. The question arises whether it makes sense to translate existing instruments or to go through the lengthy process of developing new ones. The evaluation of interprofessional seminars with quantitative instruments remains mainly on Kirkpatrick levels 1 and 2. Levels 3 and 4 can probably only be assessed with qualitative or mixed methods. German language instruments are necessary. PMID:28890927

  8. How can teachers assess reading skills of generation z learners in German language class?

    NASA Astrophysics Data System (ADS)

    Dirga, R. N.; Wijayati, P. H.

    2018-01-01

    Generation Z is a digital native generation who has unique characteristics on the daily basis includes reading. In order to assess their reading skills correctly, teachers need to take these characteristics into consideration. This paper aims to describe the process in developing an instrument to assess reading skills of Generation Z learners in German language class. This study used developmental method. The developed instrument has not only good quality but also consists of texts that are suitable for German learners of Generation Z. This instrument can be used as an example in assessing German learners’ reading skills in the 21st century.

  9. Advanced sensors and instrumentation

    NASA Technical Reports Server (NTRS)

    Calloway, Raymond S.; Zimmerman, Joe E.; Douglas, Kevin R.; Morrison, Rusty

    1990-01-01

    NASA is currently investigating the readiness of Advanced Sensors and Instrumentation to meet the requirements of new initiatives in space. The following technical objectives and technologies are briefly discussed: smart and nonintrusive sensors; onboard signal and data processing; high capacity and rate adaptive data acquisition systems; onboard computing; high capacity and rate onboard storage; efficient onboard data distribution; high capacity telemetry; ground and flight test support instrumentation; power distribution; and workstations, video/lighting. The requirements for high fidelity data (accuracy, frequency, quantity, spatial resolution) in hostile environments will continue to push the technology developers and users to extend the performance of their products and to develop new generations.

  10. The development of an instrument to measure the self-efficacy of students participating in VEX robotics competitions

    NASA Astrophysics Data System (ADS)

    Robinson, Trevor P.

    The number of robotics competitions has steadily increased over the past 30 years. Schools are implementing robotics competitions to increase student content knowledge and interest in science, technology, engineering, and mathematics (STEM). Companies in STEM-related fields are financially supporting robotics competitions to help increase the number of students pursuing careers in STEM among other reasons. These financial supporters and school administrations are asking what the outcomes of students participating in competitive robotics are. Few studies have been conducted to investigate these outcomes. The studies that have been conducted usually compare students in robotics to students not in robotics. There have not been any studies that compare students to themselves before and after participating in robotics competitions. This may be due to the lack of available instruments to measure student outcomes. This study developed an instrument to measure the self-efficacy of students participating in VEX Robotics Competitions (VRC). The VRC is the world's largest and fastest growing robotics competition available for middle and high school students. Self-efficacy was measured because of its importance to the education community. Students with higher self-efficacy tend to persevere through difficult tasks more frequently than students with low self-efficacy. A person's self-efficacy has major influence over what interests, activities, classes, college majors, and careers he or she will pursue in life. The self-efficacy survey instrument created through this study was developed through an occupational and task analysis (OTA), and initial content and face validity was established through the OTA process. Exploratory and confirmatory factor analyses were also conducted to assist in instrument validation. The reliability was calculated using Cronbach's alpha. Face validity was established through the OTA process. Construct validity was established through the factor analyses. The processes of the OTA and factor analyses have created an instrument that results indicate is reliable and valid to use in further research studies.

  11. A preview of a modular surface light scattering instrument with autotracking optics

    NASA Technical Reports Server (NTRS)

    Meyer, William V.; Tin, Padetha; Mann, J. Adin, Jr.; Cheung, H. Michael; Rogers, Richard B.; Lading, Lars

    1994-01-01

    NASA's Advanced Technology Development (ATD) program is sponsoring the development of a new generation of surface light scattering hardware. This instrument is designed to non-invasively measure the surface response function of liquids over a wide range of operating conditions while automatically compensating for a sloshing surface. The surface response function can be used to compute surface tension, properties of monolayers present, viscosity, surface tension gradient and surface temperature. The instrument uses optical and electronic building blocks developed for the laser light scattering program at NASA Lewis along with several unique surface light scattering components. The emphasis of this paper is the compensation for bulk surface motion (slosh). Some data processing background information is also included.

  12. A proposal for evaluating cognition in assertiveness.

    PubMed

    Vagos, Paula; Pereira, Anabela

    2010-09-01

    This article presents the development process and initial psychometric features of an instrument for evaluating cognition in assertiveness. This is an essential social skill for adolescent development and seems to encompass emotional, behavioral, and cognitive aspects. The instrument was created by combining both empirical and theoretical methods for item construction, aiming to evaluate the cognitive realm of assertiveness. A sample of 996 adolescent students was used to test for reliability and validity. Results indicate good psychometric properties. The instrument is composed of 4 subscales: Outer Emotional Support, Functional Personal Ability, Interpersonal Management, and Affective Personal Ability. The Assertive Interpersonal Schema Questionnaire may potentially be a useful tool in the diagnosis of, understanding of, and development of a treatment plan for individuals with persistent difficulties in social events.

  13. Comprehensive helicopter rotor instrumentation - A retrofit approach using miniature transducers

    NASA Technical Reports Server (NTRS)

    Jacklin, Stephen A.; Mort, Ray; Morrison, Dwayne

    1992-01-01

    This paper reports an approach used to retrofit a set of full-scale main rotor blades with 290 miniature pressure transducers, 46 strain gages, and 24 miniature accelerometers. Normally, in order to avoid disturbing the aerodynamics of the rotor flow field, the pressure instrumentation must be integrally built into the body of the rotor blades. However, using a method developed with NASA, miniature pressure transducers are mounted to the blade exterior surface without degrading the quality of the blade aerodynamics. Moreover, it is estimated that this approach reduced costs by more than 50 percent over building a set of pressure instrumented blades. The aerodynamic measurement objectives are presented as are instrumentation design considerations, type of instrumentation used, assembly process, and the installed instrumentation characteristics.

  14. The Mission Operations Planning Assistant

    NASA Technical Reports Server (NTRS)

    Schuetzle, James G.

    1987-01-01

    The Mission Operations Planning Assistant (MOPA) is a knowledge-based system developed to support the planning and scheduling of instrument activities on the Upper Atmospheric Research Satellite (UARS). The MOPA system represents and maintains instrument plans at two levels of abstraction in order to keep plans comprehensible to both UARS Principal Investigators and Command Management personnel. The hierarchical representation of plans also allows MOPA to automatically create detailed instrument activity plans from which spacecraft command loads may be generated. The MOPA system was developed on a Symbolics 3640 computer using the ZetaLisp and ART languages. MOPA's features include a textual and graphical interface for plan inspection and modification, recognition of instrument operational constraint violations during the planning process, and consistency maintenance between the different planning levels. This paper describes the current MOPA system.

  15. The mission operations planning assistant

    NASA Technical Reports Server (NTRS)

    Schuetzle, James G.

    1987-01-01

    The Mission Operations Planning Assistant (MOPA) is a knowledge-based system developed to support the planning and scheduling of instrument activities on the Upper Atmospheric Research Satellite (UARS). The MOPA system represents and maintains instrument plans at two levels of abstraction in order to keep plans comprehensible to both UARS Prinicpal Investigators and Command Management personnel. The hierarchical representation of plans also allows MOPA to automatically create detailed instrument activity plans from which spacecraft command loads may be generated. The MOPA system was developed on a Symbolics 3640 computer using the ZETALISP and ART languages. MOPA's features include a textual and graphical interface for plan inspection and modification, recognition of instrument operational constraint violations during the planning process, and consistency maintenance between the different planning levels. This paper describes the current MOPA system.

  16. Designing a Likert-Type Scale to Predict Environmentally Responsible Behavior in Undergraduate Students: A Multistep Process.

    ERIC Educational Resources Information Center

    Smith-Sebasto, N. J.; D'Costa, Ayres

    1995-01-01

    Describes an attempt to develop a reliable and valid instrument to assess the relationship between locus of control of reinforcement and environmentally responsible behavior. Presents a six-step psychometric process used to develop the Environmental Action Internal Control Index (EAICI) for undergraduate students. Contains 54 references. (JRH)

  17. Sense of Classroom Community and Team Development Process in Online Learning

    ERIC Educational Resources Information Center

    Erdem Aydin, Irem; Gumus, Salih

    2016-01-01

    The purpose of this study is to determine whether there is a relationship between Turkish online learners' sense of classroom community, perceptions of success in team development process and their preferences of studying in teams. A survey instrument included the Sense of Classroom Community Scale, Tuckman's Teamwork Questionnaire and some other…

  18. Developing and Validating Proof Comprehension Tests in Undergraduate Mathematics

    ERIC Educational Resources Information Center

    Mejía-Ramos, Juan Pablo; Lew, Kristen; de la Torre, Jimmy; Weber, Keith

    2017-01-01

    In this article, we describe and illustrate the process by which we developed and validated short, multiple-choice, reliable tests to assess undergraduate students' comprehension of three mathematical proofs. We discuss the purpose for each stage and how it benefited the design of our instruments. We also suggest ways in which this process could…

  19. The Development and Validation of Scores on the Mathematics Information Processing Scale (MIPS).

    ERIC Educational Resources Information Center

    Bessant, Kenneth C.

    1997-01-01

    This study reports on the development and psychometric properties of a new 87-item Mathematics Information Processing Scale that explores learning strategies, metacognitive problem-solving skills, and attentional deployment. Results with 340 college students support the use of the instrument, for which factor analysis identified five theoretically…

  20. Measuring the diffusion of innovative health promotion programs.

    PubMed

    Steckler, A; Goodman, R M; McLeroy, K R; Davis, S; Koch, G

    1992-01-01

    Once a health promotion program has proven to be effective in one or two initial settings, attempts may be made to transfer the program to new settings. One way to conceptualize the transference of health promotion programs from one locale to another is by considering the programs to be innovations that are being diffused. In this way, diffusion of innovation theory can be applied to guide the process of program transference. This article reports on the development of six questionnaires to measure the extent to which health promotion programs are successfully disseminated: Organizational Climate, Awareness-Concern, Rogers's Adoption Variables, Level of Use, Level of Success, and Level of Institutionalization. The instruments are being successfully used in a study of the diffusion of health promotion/tobacco prevention curricula to junior high schools in North Carolina. The instruments, which measure the four steps of the diffusion process, have construct validity since they were developed within existing theories and are derived from the work of previous researchers. No previous research has attempted to use instruments like these to measure sequentially the stages of the diffusion process.

  1. Assessment of the measurement properties of the post stroke motor function instruments available in Brazil: a systematic review.

    PubMed

    Lima, Elaine; Teixeira-Salmela, Luci F; Simões, Luan; Guerra, Ana C C; Lemos, Andrea

    2016-03-15

    While there are several instruments in Brazil that measure motor function in patients after stroke, it is unknown whether the measurement properties of these instruments are appropriate. To identify the motor function instruments available in Brazil for patients after stroke. To assess the methodological quality of the studies and the results related to the measurement properties of these instruments. Two independent reviewers conducted searches on PubMed, LILACS, CINAHL, Web of Science, and Scopus. Studies that aimed to cross-culturally adapt an existing instrument or create a Brazilian instrument and test at least one measurement property related to motor function in patients after stroke were included. The methodological quality of these studies was checked by the COSMIN checklist with 4-point rating scale and the results of the measurement properties were analyzed by the criteria developed by Terwee et al. A total of 11 instruments were considered eligible, none of which were created in Brazil. The process of cross-cultural adaptation was inadequate in 10 out of 11 instruments due to the lack of back-translation or due to inappropriate target population. All of the instruments presented flaws in the measurement properties, especially reliability, internal consistency, and construct validity. The flaws observed in both cross-cultural adaptation process and testing measurement properties make the results inconclusive on the validity of the available instruments. Adequate procedures of cross-cultural adaptation and measurement properties of these instruments are strongly needed.

  2. Assessment of the measurement properties of the post stroke motor function instruments available in Brazil: a systematic review

    PubMed Central

    Lima, Elaine; Teixeira-Salmela, Luci F.; Simões, Luan; Guerra, Ana C. C.; Lemos, Andrea

    2016-01-01

    Background While there are several instruments in Brazil that measure motor function in patients after stroke, it is unknown whether the measurement properties of these instruments are appropriate. Objective To identify the motor function instruments available in Brazil for patients after stroke. To assess the methodological quality of the studies and the results related to the measurement properties of these instruments. Method Two independent reviewers conducted searches on PubMed, LILACS, CINAHL, Web of Science, and Scopus. Studies that aimed to cross-culturally adapt an existing instrument or create a Brazilian instrument and test at least one measurement property related to motor function in patients after stroke were included. The methodological quality of these studies was checked by the COSMIN checklist with 4-point rating scale and the results of the measurement properties were analyzed by the criteria developed by Terwee et al. Results A total of 11 instruments were considered eligible, none of which were created in Brazil. The process of cross-cultural adaptation was inadequate in 10 out of 11 instruments due to the lack of back-translation or due to inappropriate target population. All of the instruments presented flaws in the measurement properties, especially reliability, internal consistency, and construct validity. Conclusion The flaws observed in both cross-cultural adaptation process and testing measurement properties make the results inconclusive on the validity of the available instruments. Adequate procedures of cross-cultural adaptation and measurement properties of these instruments are strongly needed. PMID:26982452

  3. Serologic test development. Progress report, July 1, 1974--June 30, 1975. [Radioimmunoassay method for diagnosis of swine and bovine diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saunders, G.C.; Clinard, E.H.; Sanders, W.M.

    1975-01-01

    The Enzyme-Labeled Antibody (ELA) test system has been adapted to microtiter trays for both cell bound and soluble antigens. Problems involving both readout instrumentation and reaction product stability have been solved. Progress involving application of the ELA system for detection of hog cholera, trichinosis, swine brucellosis, and swine and bovine tuberculosis is reported. Prototype instrumentation for automating ELA processing is being developed. (auth)

  4. Developments in FT-ICR MS instrumentation, ionization techniques, and data interpretation methods for petroleomics.

    PubMed

    Cho, Yunju; Ahmed, Arif; Islam, Annana; Kim, Sunghwan

    2015-01-01

    Because of the increasing importance of heavy and unconventional crude oil as an energy source, there is a growing need for petroleomics: the pursuit of more complete and detailed knowledge of the chemical compositions of crude oil. Crude oil has an extremely complex nature; hence, techniques with ultra-high resolving capabilities, such as Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), are necessary. FT-ICR MS has been successfully applied to the study of heavy and unconventional crude oils such as bitumen and shale oil. However, the analysis of crude oil with FT-ICR MS is not trivial, and it has pushed analysis to the limits of instrumental and methodological capabilities. For example, high-resolution mass spectra of crude oils may contain over 100,000 peaks that require interpretation. To visualize large data sets more effectively, data processing methods such as Kendrick mass defect analysis and statistical analyses have been developed. The successful application of FT-ICR MS to the study of crude oil has been critically dependent on key developments in FT-ICR MS instrumentation and data processing methods. This review offers an introduction to the basic principles, FT-ICR MS instrumentation development, ionization techniques, and data interpretation methods for petroleomics and is intended for readers having no prior experience in this field of study. © 2014 Wiley Periodicals, Inc.

  5. Effective learning among elite football players: the development of a football-specific self-regulated learning questionnaire.

    PubMed

    Toering, Tynke; Jordet, Geir; Ripegutu, Anders

    2013-01-01

    The present study aimed to develop a football-specific self-report instrument measuring self-regulated learning in the context of daily practice, which can be used to monitor the extent to which players take responsibility for their own learning. Development of the instrument involved six steps: 1. Literature review based on Zimmerman's (2006) theory of self-regulated learning, 2. Item generation, 3. Item validation, 4. Pilot studies, 5. Exploratory factor analysis (EFA), and 6. Confirmatory factor analysis (CFA). The instrument was tested for reliability and validity among 204 elite youth football players aged 13-16 years (Mage = 14.6; s = 0.60; 123 boys, 81 girls). The EFA indicated that a five-factor model fitted the observed data best (reflection, evaluation, planning, speaking up, and coaching). However, the CFA showed that a three-factor structure including 22 items produced a satisfactory model fit (reflection, evaluation, and planning; non-normed fit index [NNFI] = 0.96, comparative fit index [CFI] = 0.95, root mean square error of approximation [RMSEA] = 0.067). While the self-regulation processes of reflection, evaluation, and planning are strongly related and fit well into one model, other self-regulated learning processes seem to be more individually determined. In conclusion, the questionnaire developed in this study is considered a reliable and valid instrument to measure self-regulated learning among elite football players.

  6. Development of an instrument to analyze organizational characteristics in multidisciplinary care pathways; the case of colorectal cancer.

    PubMed

    Pluimers, Dorine J; van Vliet, Ellen J; Niezink, Anne Gh; van Mourik, Martijn S; Eddes, Eric H; Wouters, Michel W; Tollenaar, Rob A E M; van Harten, Wim H

    2015-04-09

    To analyze the organization of multidisciplinary care pathways such as colorectal cancer care, an instrument was developed based on a recently published framework that was earlier used in analyzing (monodisciplinary) specialist cataract care from a lean perspective. The instrument was constructed using semi-structured interviews and direct observation of the colorectal care process based on a Rapid Plant Assessment. Six lean aspects that were earlier established that highly impact process design, were investigated: operational focus, autonomous work cell, physical lay-out of resources, multi-skilled team, pull planning and non-value adding activities. To test reliability, clarity and face validity of the instrument, a pilot study was performed in eight Dutch hospitals. In the pilot it proved feasible to apply the instrument and generate the intended information. The instrument consisted of 83 quantitative and 24 qualitative items. Examples of results show differences in operational focus, number of patient visits needed for diagnosis, numbers of staff involved with treatment, the implementation of protocols and utilization of one-stop-shops. Identification of waste and non-value adding activities may need further attention. Based on feedback from involved clinicians the face validity was acceptable and the results provided useful feedback- and benchmark data. The instrument proved to be reliable and valid for broader implementation in Dutch health care. The limited number of cases made statistical analysis not possible and further validation studies may shed better light on variation. This paper demonstrates the use of an instrument to analyze organizational characteristics in colorectal cancer care from a lean perspective. Wider use might help to identify best organizational practices for colorectal surgery. In larger series the instrument might be used for in-depth research into the relation between organization and patient outcomes. Although we found no reason to adapt the underlying framework, recommendations were made for further development to enable use in different tumor- and treatment modalities and in larger (international) samples that allow for more advanced statistical analysis. Waste from defective care or from wasted human potential will need further elaboration of the instrument.

  7. A Versatile Planetary Radio Science Microreceiver

    NASA Technical Reports Server (NTRS)

    Fry, Craig D.; Rosenberg, T. J.

    1999-01-01

    We have developed a low-power. programmable radio "microreceiver" that combines the functionality of two science instruments: a Relative Ionospheric Opacity Meter (riometer) and a swept-frequency, VTF/HF radio spectrometer. The radio receiver, calibration noise source, data acquisition and processing, and command and control functions are all contained on a single circuit board. This design is suitable for miniaturizing as a complete flight instrument. Several of the subsystems were implemented in a field-programmable gate array (FPGA), including the receiver detector, the control logic, and the data acquisition and processing blocks. Considerable efforts were made to reduce the power consumption of the instrument, and eliminate or minimize RF noise and spurious emissions generated by the receiver's digital circuitry. A prototype instrument was deployed at McMurdo Station, Antarctica, and operated in parallel with a traditional riometer instrument for approximately three weeks. The attached paper (accepted for publication by Radio Science) describes in detail the microreceiver theory of operation, performance specifications and test results.

  8. Material Analysis and Identification

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KeyMaster Technologies, Inc., develops and markets specialized, hand-held X-ray fluorescence (XRF) instruments and unique tagging technology used to identify and authenticate materials or processes. NASA first met with this Kennewick, Washington-based company as the Agency began seeking companies to develop a hand-held instrument that would detect data matrix symbols on parts covered by paint and other coatings. Since the Federal Aviation Administration was also searching for methods to detect and eliminate the use of unapproved parts, it recommended that NASA and KeyMaster work together to develop a technology that would benefit both agencies.

  9. Serologic test systems development. Progress report, July 1, 1976--September 30, 1977

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saunders, G.C.; Clinard, E.H.; Bartlett, M.L.

    1978-01-01

    Work has continued on the development and application of the Enzyme-Labeled Antibody (ELA) test to the USDA needs. Results on trichinosis, brucellosis, and staphylococcal enterotoxin A detection are very encouraging. A field test for trichinosis detection is being worked out in cooperation with Food Safety and Quality Service personnel. Work is in progress with the Technicon Instrument Corporation to develop a modification of their equipment to automatically process samples by the ELA procedure. An automated ELA readout instrument for 96-well trays has been completed and is being checked out.

  10. The development and pilot testing of an instrument to measure nurses' working environment: the Nursing Context Index.

    PubMed

    Slater, Paul; McCormack, Brendan; Bunting, Brendan

    2009-01-01

    Evidence shows that adopting a person-centered approach to nursing alters the work environment, reduces anxiety levels among nurses in the long term, promotes teamwork among staff, and increases job satisfaction. However, few studies have attempted to quantify the outcomes from the adoption of person-centered nursing. The lack of outcome measurement is in part influenced by the lack of a standardized instrument to measure person-centered nursing. The aim of this study was to develop an instrument (the Nursing Context Index) to inform the development of person-centered nursing and outcomes arising. The Nursing Context Index (NCI) was developed through three stages. Stage 1 involved a systematic literature review to identify the key characteristics that needed to be considered in the instrument. Stage 2 involved the identification and selection of items for inclusion in the instrument identified through focus group discussions. A 19-construct instrument was developed. Face validity and content validity were gauged. In Stage 3, a pilot study (n = 23) was conducted to test the instrument. Measures of internal consistency were ensured using Cronbach's alpha. Criterion-related validity of the instrument was ensured through comparison between factors contained in the instrument. Findings show that the NCI is an accurate representation of the factors influenced by a clinical setting's progression to person-centered nursing. The factors were deemed appropriate to the clinical settings, and possessed face and content validity. Initial statistical findings confirm the validity and usability of the NCI. The process used for the development and testing of the instrument was found to be effective. The NCI was deemed to be an effective measure of factors influenced by the implementation of person-centered nursing and would help in redressing a scarcity of quantitative evidence to examine the benefits of nurses working in a person-centered manner.

  11. Fitness to plead: Development and validation of a standardised assessment instrument

    PubMed Central

    Stahl, Daniel; Appiah-Kusi, Elizabeth; Brewer, Rebecca; Watts, Michael; Peay, Jill; Blackwood, Nigel

    2018-01-01

    The ability of an individual to participate in courtroom proceedings is assessed by clinicians using legal ‘fitness to plead’ criteria. Findings of ‘unfitness’ are so rare that there is considerable professional unease concerning the utility of the current subjective assessment process. As a result, mentally disordered defendants may be subjected unfairly to criminal trials. The Law Commission in England and Wales has proposed legal reform, as well as the utilisation of a defined psychiatric instrument to assist in fitness to plead assessments. Similar legal reforms are occurring in other jurisdictions. Our objective was to produce and validate a standardised assessment instrument of fitness to plead employing a filmed vignette of criminal proceedings. The instrument was developed in consultation with legal and clinical professionals, and was refined using standard item reduction methods in two initial rounds of testing (n = 212). The factorial structure, test-retest reliability and convergent validity of the resultant instrument were assessed in a further round (n = 160). As a result of this iterative process a 25-item scale was produced, with an underlying two-factor structure representing the foundational and decision-making abilities underpinning fitness to plead. The sub-scales demonstrate good internal consistency (factor 1: 0·76; factor 2: 0·65) and test-retest stability (0·7) as well as excellent convergent validity with scores of intelligence, executive function and mentalising abilities (p≤0·01 in all domains). Overall the standardised Fitness to Plead Assessment instrument has good psychometric properties. It has the potential to ensure that the significant numbers of mentally ill and cognitively impaired individuals who face trial are objectively assessed, and the courtroom process critically informed. PMID:29698396

  12. High performance low cost interconnections for flip chip attachment with electrically conductive adhesive. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-05-01

    This final report is a compilation of final reports from each of the groups participating in the program. The main three groups involved in this effort are the Thomas J. Watson Research Center of IBM Corporation in Yorktown Heights, New York, Assembly Process Design of IBM Corporation in Endicott, New York, and SMT Laboratory of Universal Instruments Corporation in Binghamton, New York. The group at the research center focused on the conductive adhesive materials development and characterization. The group in process development focused on processing of the Polymer-Metal-Solvent Paste (PMSP) to form conductive adhesive bumps, formation of the Polymer-Metal Compositemore » (PMC) on semiconductor devices and study of the bonding process to circuitized organic carriers, and the long term durability and reliability of joints formed using the process. The group at Universal Instruments focused on development of an equipment set and bonding parameters for the equipment to produce bond assembly tooling. Reports of each of these individual groups are presented here reviewing their technical efforts and achievements.« less

  13. Assessing collaborative computing: development of the Collaborative-Computing Observation Instrument (C-COI)

    NASA Astrophysics Data System (ADS)

    Israel, Maya; Wherfel, Quentin M.; Shehab, Saadeddine; Ramos, Evan A.; Metzger, Adam; Reese, George C.

    2016-07-01

    This paper describes the development, validation, and uses of the Collaborative Computing Observation Instrument (C-COI), a web-based analysis instrument that classifies individual and/or collaborative behaviors of students during computing problem-solving (e.g. coding, programming). The C-COI analyzes data gathered through video and audio screen recording software that captures students' computer screens as they program, and their conversations with their peers or adults. The instrument allows researchers to organize and quantify these data to track behavioral patterns that could be further analyzed for deeper understanding of persistence and/or collaborative interactions. The article provides a rationale for the C-COI including the development of a theoretical framework for measuring collaborative interactions in computer-mediated environments. This theoretical framework relied on the computer-supported collaborative learning literature related to adaptive help seeking, the joint problem-solving space in which collaborative computing occurs, and conversations related to outcomes and products of computational activities. Instrument development and validation also included ongoing advisory board feedback from experts in computer science, collaborative learning, and K-12 computing as well as classroom observations to test out the constructs in the C-COI. These processes resulted in an instrument with rigorous validation procedures and a high inter-rater reliability.

  14. Instrument to synchronize Thomson scattering diagnostic measurements with MHD acitivity in a tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wintenberg, A.L.

    1985-04-01

    An instrument to synchronize the firing of a ruby laser for a Thomson scattering diagnostic with plasma oscillations was designed, developed, and evaluated. The instrument will fire the laser at a user-selected phase of an input sine or sawtooth wave with an accuracy of +-15/sup 0/. Allowable frequencies range from 20 to 500 Hz for a sawtooth and from 1 to 30 kHz for a sine wave. The instrument also allows synchronization with a sine wave to be enabled by a preselected sawtooth phase. The instrument uses analog signal processing circuits to separate the signal components, remove unwanted components, andmore » produce zero-phase synchronization pulses. The instrument measures the period between zero-phase pulses in order to produce phase synchronization pulses delayed a fraction of the period from the zero-phase pulses. The laser is fired by the phase synchronization pulse. Unwanted signal components are attenuated by bandpass filters. A digitally controlled self-adjusting bandpass filter for sine processing. The instrument was used to investigate the variation of the electron temperature profile with the phase of the x-ray signal from an Impurity Studies Experiment (ISX-B) plasma exhibiting magnetohydrodynamic (MHD) activity.« less

  15. Acousto-Optic Tunable Filter Spectroscopic Instrumentation for Quantitative Near-Ir Analysis of Organic Materials.

    NASA Astrophysics Data System (ADS)

    Eilert, Arnold James

    1995-01-01

    The utility of near-IR spectroscopy for routine quantitative analyses of a wide variety of compositional, chemical, or physical parameters of organic materials is well understood. It can be used for relatively fast and inexpensive non-destructive bulk material analysis before, during, and after processing. It has been demonstrated as being a particularly useful technique for numerous analytical applications in cereal (food and feed) science and industry. Further fulfillment of the potential of near-IR spectroscopic analysis, both in the process and laboratory environment, is reliant upon the development of instrumentation that is capable of meeting the challenges of increasingly difficult applications. One approach to the development of near-IR spectroscopic instrumentation that holds a great deal of promise is acousto-optic tunable filter (AOTF) technology. A combination of attributes offered by AOTF spectrometry, including speed, optical throughput, wavelength reproducibility, ruggedness (no -moving-parts operation) and flexibility, make it particularly desirable for numerous applications. A series of prototype (research model) acousto -optic tunable filter instruments were developed and tested in order to investigate the feasibility of the technology for quantitative near-IR spectrometry. Development included design, component procurement, assembly and/or configuration of the optical and electronic subsystems of which each functional spectrometer arrangement was comprised, as well as computer interfacing and acquisition/control software development. Investigation of this technology involved an evolution of several operational spectrometer systems, each of which offered improvements over its predecessor. Appropriate testing was conducted at various stages of development. Demonstrations of the potential applicability of our AOTF spectrometer to quantitative process monitoring or laboratory analysis of numerous organic substances, including food materials, were performed. Lipid determination in foods by spectroscopic analysis of a solvent used after cold batch extraction and simulated supercritical fluid extraction monitoring were among the applications tested. The ultimate performance specifications of our instrument included full-range wavelength coverage from 1250 to 2400 nm (with random, segmented range, or continuous range wavelength access capability), real -time quantitative analysis rates in excess of 150 determinations per second, and full range (2 nm increment) scanning speeds of 200 milliseconds.

  16. Visual Data-Analytics of Large-Scale Parallel Discrete-Event Simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ross, Caitlin; Carothers, Christopher D.; Mubarak, Misbah

    Parallel discrete-event simulation (PDES) is an important tool in the codesign of extreme-scale systems because PDES provides a cost-effective way to evaluate designs of highperformance computing systems. Optimistic synchronization algorithms for PDES, such as Time Warp, allow events to be processed without global synchronization among the processing elements. A rollback mechanism is provided when events are processed out of timestamp order. Although optimistic synchronization protocols enable the scalability of large-scale PDES, the performance of the simulations must be tuned to reduce the number of rollbacks and provide an improved simulation runtime. To enable efficient large-scale optimistic simulations, one has tomore » gain insight into the factors that affect the rollback behavior and simulation performance. We developed a tool for ROSS model developers that gives them detailed metrics on the performance of their large-scale optimistic simulations at varying levels of simulation granularity. Model developers can use this information for parameter tuning of optimistic simulations in order to achieve better runtime and fewer rollbacks. In this work, we instrument the ROSS optimistic PDES framework to gather detailed statistics about the simulation engine. We have also developed an interactive visualization interface that uses the data collected by the ROSS instrumentation to understand the underlying behavior of the simulation engine. The interface connects real time to virtual time in the simulation and provides the ability to view simulation data at different granularities. We demonstrate the usefulness of our framework by performing a visual analysis of the dragonfly network topology model provided by the CODES simulation framework built on top of ROSS. The instrumentation needs to minimize overhead in order to accurately collect data about the simulation performance. To ensure that the instrumentation does not introduce unnecessary overhead, we perform a scaling study that compares instrumented ROSS simulations with their noninstrumented counterparts in order to determine the amount of perturbation when running at different simulation scales.« less

  17. Redesigning Task Sequences to Support Instrumental Genesis in the Use of Movable Points and Slider Bars

    ERIC Educational Resources Information Center

    Fahlgren, Maria

    2017-01-01

    This paper examines the process of instrumental genesis through which students develop their proficiency in making use of movable points and slider bars--two tools that dynamic mathematics software provides for working with variable coordinates and parameters in the field of functions. The paper analyses students' responses to task sequences…

  18. Understanding Metallic Bonding: Structure, Process and Interaction by Rasch Analysis

    ERIC Educational Resources Information Center

    Cheng, Maurice M. W.; Oon, Pey-Tee

    2016-01-01

    This paper reports the results of a survey of 3006 Year 10-12 students on their understandings of metallic bonding. The instrument was developed based on Chi's ontological categories of scientific concepts and students' understanding of metallic bonding as reported in the literature. The instrument has two parts. Part one probed into students'…

  19. Toward Development of a Generalized Instrument to Measure Andragogy

    ERIC Educational Resources Information Center

    Holton, Elwood F., III; Wilson, Lynda Swanson; Bates, Reid A.

    2009-01-01

    Andragogy has emerged as one of the dominant frameworks for teaching adults during the past 40 years. A major and glaring gap in andragogy research is the lack of a measurement instrument that adequately measures both andragogical principles and process design elements. As a result, no definitive empirical test of the theory has been possible. The…

  20. School Self-Evaluation Instruments and Cognitive Validity. Do Items Capture What They Intend to?

    ERIC Educational Resources Information Center

    Faddar, Jerich; Vanhoof, Jan; De Maeyer, Sven

    2017-01-01

    School self-evaluation (SSE) often makes use of questionnaires in order to sketch a picture of the school. How respondents cognitively process questionnaire items determines the validity of SSE results. Still, one readily assumes that respondents interpret and answer items as intended by the instrument developer (referred to as cognitive…

  1. Development and Validation of an Instrument to Measure Students' Motivation and Self-Regulation in Science Learning

    ERIC Educational Resources Information Center

    Velayutham, Sunitadevi; Aldridge, Jill; Fraser, Barry

    2011-01-01

    Students' motivational beliefs and self-regulatory practices have been identified as instrumental in influencing the engagement of students in the learning process. An important aim of science education is to empower students by nurturing the belief that they can succeed in science learning and to cultivate the adaptive learning strategies…

  2. The Development of an Instrument to Measure the Project Competences of College Students in Online Project-Based Learning

    NASA Astrophysics Data System (ADS)

    Lin, Chien-Liang

    2018-02-01

    This study sought to develop a self-report instrument to be used in the assessment of the project competences of college students engaged in online project-based learning. Three scales of the KIPSSE instrument developed for this study, namely, the knowledge integration, project skills, and self-efficacy scales, were based on related theories and the analysis results of three project advisor interviews. Those items of knowledge integration and project skill scales focused on the integration of different disciplines and technological skills separately. Two samples of data were collected from information technology-related courses taught with an online project-based learning strategy over different semesters at a college in southern Taiwan. The validity and reliability of the KIPSSE instrument were confirmed through item analysis and confirmatory factor analysis using structural equation modeling of two samples of students' online response sets separately. The Cronbach's alpha reliability coefficient for the entire instrument was 0.931; for each scale, the alpha ranged from 0.832 to 0.907. There was also a significant correlation ( r = 0.55, p < 0.01) between the KIPSSE instrument results and the students' product evaluation scores. The findings of this study confirmed the validity and reliability of the KIPSSE instrument. The confirmation process and related implications are also discussed.

  3. Addressing continuous data measured with different instruments for participants excluded from trial analysis: a guide for systematic reviewers.

    PubMed

    Ebrahim, Shanil; Johnston, Bradley C; Akl, Elie A; Mustafa, Reem A; Sun, Xin; Walter, Stephen D; Heels-Ansdell, Diane; Alonso-Coello, Pablo; Guyatt, Gordon H

    2014-05-01

    We previously developed an approach to address the impact of missing participant data in meta-analyses of continuous variables in trials that used the same measurement instrument. We extend this approach to meta-analyses including trials that use different instruments to measure the same construct. We reviewed the available literature, conducted an iterative consultative process, and developed an approach involving a complete-case analysis complemented by sensitivity analyses that apply a series of increasingly stringent assumptions about results in patients with missing continuous outcome data. Our approach involves choosing the reference measurement instrument; converting scores from different instruments to the units of the reference instrument; developing four successively more stringent imputation strategies for addressing missing participant data; calculating a pooled mean difference for the complete-case analysis and imputation strategies; calculating the proportion of patients who experienced an important treatment effect; and judging the impact of the imputation strategies on the confidence in the estimate of effect. We applied our approach to an example systematic review of respiratory rehabilitation for chronic obstructive pulmonary disease. Our extended approach provides quantitative guidance for addressing missing participant data in systematic reviews of trials using different instruments to measure the same construct. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Content validity of governing in Building Information Modelling (BIM) implementation assessment instrument

    NASA Astrophysics Data System (ADS)

    Hadzaman, N. A. H.; Takim, R.; Nawawi, A. H.; Mohamad Yusuwan, N.

    2018-04-01

    BIM governance assessment instrument is a process of analysing the importance in developing BIM governance solution to tackle the existing problems during team collaboration in BIM-based projects. Despite the deployment of integrative technologies in construction industry particularly BIM, it is still insufficient compare to other sectors. Several studies have been established the requirements of BIM implementation concerning all technical and non-technical BIM adoption issues. However, the data are regarded as inadequate to develop a BIM governance framework. Hence, the objective of the paper is to evaluate the content validity of the BIM governance instrument prior to the main data collection. Two methods were employed in the form of literature review and questionnaire survey. Based on the literature review, 273 items with six main constructs are suggested to be incorporated in the BIM governance instrument. The Content Validity Ratio (CVR) scores revealed that 202 out of 273 items are considered as the utmost critical by the content experts. The findings for Item Level Content Validity Index (I-CVI) and Modified Kappa Coefficient however revealed that 257 items in BIM governance instrument are appropriate and excellent. The instrument is highly reliable for future strategies and the development of BIM projects in Malaysia.

  5. The Integration of Word Processing with Data Processing in an Educational Environment. Final Report.

    ERIC Educational Resources Information Center

    Patterson, Lorna; Schlender, Jim

    A project examined the Office of the Future and determined trends regarding an integration of word processing and data processing. It then sought to translate those trends into an educational package to develop the potential information specialist. A survey instrument completed by 33 office managers and word processing and data processing…

  6. Effectiveness of Teamwork in an Integrated Care Setting for Patients with COPD: Development and Testing of a Self-Evaluation Instrument for Interprofessional Teams.

    PubMed

    Van Dijk-de Vries, Anneke N; Duimel-Peeters, Inge G P; Muris, Jean W; Wesseling, Geertjan J; Beusmans, George H M I; Vrijhoef, Hubertus J M

    2016-04-08

    Teamwork between healthcare providers is conditional for the delivery of integrated care. This study aimed to assess the usefulness of the conceptual framework Integrated Team Effectiveness Model for developing and testing of the Integrated Team Effectiveness Instrument. Focus groups with healthcare providers in an integrated care setting for people with chronic obstructive pulmonary disease (COPD) were conducted to examine the recognisability of the conceptual framework and to explore critical success factors for collaborative COPD practice out of this framework. The resulting items were transposed into a pilot instrument. This was reviewed by expert opinion and completed 153 times by healthcare providers. The underlying structure and internal consistency of the instrument were verified by factor analysis and Cronbach's alpha. The conceptual framework turned out to be comprehensible for discussing teamwork effectiveness. The pilot instrument measures 25 relevant aspects of teamwork in integrated COPD care. Factor analysis suggested three reliable components: teamwork effectiveness, team processes and team psychosocial traits (Cronbach's alpha between 0.76 and 0.81). The conceptual framework Integrated Team Effectiveness Model is relevant in developing a practical full-spectrum instrument to facilitate discussing teamwork effectiveness. The Integrated Team Effectiveness Instrument provides a well-founded basis to self-evaluate teamwork effectiveness in integrated COPD care by healthcare providers. Recommendations are provided for the improvement of the instrument.

  7. Competencies in HRD. Symposium.

    ERIC Educational Resources Information Center

    2002

    This symposium is comprised of three papers on competencies in human resource development (HRD). "The Development of a Competency Model and Assessment Instrument for Public Sector Leadership and Management Development" (Sharon S. Naquin, Elwood F. Holton III) reports on a streamlined methodology and process used to develop a competency…

  8. The development of a clinical outcomes survey research application: Assessment CenterSM

    PubMed Central

    Rothrock, Nan E.; Hanrahan, Rachel T.; Jansky, Liz J.; Harniss, Mark; Riley, William

    2013-01-01

    Introduction The National Institutes of Health sponsored Patient-Reported Outcome Measurement Information System (PROMIS) aimed to create item banks and computerized adaptive tests (CATs) across multiple domains for individuals with a range of chronic diseases. Purpose Web-based software was created to enable a researcher to create study-specific Websites that could administer PROMIS CATs and other instruments to research participants or clinical samples. This paper outlines the process used to develop a user-friendly, free, Web-based resource (Assessment CenterSM) for storage, retrieval, organization, sharing, and administration of patient-reported outcomes (PRO) instruments. Methods Joint Application Design (JAD) sessions were conducted with representatives from numerous institutions in order to supply a general wish list of features. Use Cases were then written to ensure that end user expectations matched programmer specifications. Program development included daily programmer “scrum” sessions, weekly Usability Acceptability Testing (UAT) and continuous Quality Assurance (QA) activities pre- and post-release. Results Assessment Center includes features that promote instrument development including item histories, data management, and storage of statistical analysis results. Conclusions This case study of software development highlights the collection and incorporation of user input throughout the development process. Potential future applications of Assessment Center in clinical research are discussed. PMID:20306332

  9. Tunable Light-Guide Image Processing Snapshot Spectrometer (TuLIPSS) for Earth and Moon Observations

    NASA Astrophysics Data System (ADS)

    Tkaczyk, T. S.; Alexander, D.; Luvall, J. C.; Wang, Y.; Dwight, J. G.; Pawlowsk, M. E.; Howell, B.; Tatum, P. F.; Stoian, R.-I.; Cheng, S.; Daou, A.

    2018-02-01

    A tunable light-guide image processing snapshot spectrometer (TuLIPSS) for Earth science research and observation is being developed through a NASA instrument incubator project with Rice University and Marshall Space Flight Center.

  10. TOGA - A GNSS Reflections Instrument for Remote Sensing Using Beamforming

    NASA Technical Reports Server (NTRS)

    Esterhuizen, S.; Meehan, T. K.; Robison, D.

    2009-01-01

    Remotely sensing the Earth's surface using GNSS signals as bi-static radar sources is one of the most challenging applications for radiometric instrument design. As part of NASA's Instrument Incubator Program, our group at JPL has built a prototype instrument, TOGA (Time-shifted, Orthometric, GNSS Array), to address a variety of GNSS science needs. Observing GNSS reflections is major focus of the design/development effort. The TOGA design features a steerable beam antenna array which can form a high-gain antenna pattern in multiple directions simultaneously. Multiple FPGAs provide flexible digital signal processing logic to process both GPS and Galileo reflections. A Linux OS based science processor serves as experiment scheduler and data post-processor. This paper outlines the TOGA design approach as well as preliminary results of reflection data collected from test flights over the Pacific ocean. This reflections data demonstrates observation of the GPS L1/L2C/L5 signals.

  11. Phased Array Feeds

    NASA Astrophysics Data System (ADS)

    Fisher, J. Richard; Bradley, Richard F.; Brisken, Walter F.; Cotton, William D.; Emerson, Darrel T.; Kerr, Anthony R.; Lacasse, Richard J.; Morgan, Matthew A.; Napier, Peter J.; Norrod, Roger D.; Payne, John M.; Pospieszalski, Marian W.; Symmes, Arthur; Thompson, A. Richard; Webber, John C.

    2009-03-01

    This white paper offers cautionary observations about the planning and development of new, large radio astronomy instruments. Complexity is a strong cost driver so every effort should be made to assign differing science requirements to different instruments and probably different sites. The appeal of shared resources is generally not realized in practice and can often be counterproductive. Instrument optimization is much more difficult with longer lists of requirements, and the development process is longer and less efficient. More complex instruments are necessarily further behind the technology state of the art because of longer development times. Including technology R&D in the construction phase of projects is a growing trend that leads to higher risks, cost overruns, schedule delays, and project de-scoping. There are no technology breakthroughs just over the horizon that will suddenly bring down the cost of collecting area. Advances come largely through careful attention to detail in the adoption of new technology provided by industry and the commercial market. Radio astronomy instrumentation has a very bright future, but a vigorous long-term R&D program not tied directly to specific projects needs to be restored, fostered, and preserved.

  12. The development of an instrument to measure teachers' use of fear appeals in the GCSE classroom.

    PubMed

    Putwain, David W; Roberts, Christine M

    2009-12-01

    Previous work has suggested that teachers of General Certificate of Secondary Education classes may use fear appeals as a motivational device but these may have unwanted consequences by increasing examination-related anxiety in students. To facilitate future work in this area, an instrument was developed to measure teachers' use of fear appeals in the course of normal classroom instruction. Students in their final 2 years of compulsory schooling in England: 192 in Study 1 and 133 in Study 2. A construct validity approach was used in the development of this instrument. Study 1 reports the development and piloting of this measure. Study 2 reports refinement of this measure and relations with other constructs. A three-factor structure provided a reasonable model fit and all factors demonstrated acceptable reliability. Factors 1 and 2 described the perceived frequency of fear appeals made in relation to educational/occupational consequences and the third factor described the perceived threat of fear appeals. This instrument has demonstrated sufficient convergent and discriminant validity and reliability to be used in subsequent research, although the validation process should continue and it is hoped that the instrument will be adapted for use in other contexts.

  13. The geostationary Earth radiation budget (GERB) instrument on EUMETSAT's MSG satellite

    NASA Astrophysics Data System (ADS)

    Sandford, M. C. W.; Allan, P. M.; Caldwell, M. E.; Delderfield, J.; Oliver, M. B.; Sawyer, E.; Harries, J. E.; Ashmall, J.; Brindley, H.; Kellock, S.; Mossavati, R.; Wrigley, R.; Llewellyn-Jones, D.; Blake, O.; Butcher, G.; Cole, R.; Nelms, N.; DeWitte, S.; Gloesener, P.; Fabbrizzi, F.

    2003-12-01

    Geostationary Earth radiation budget (GERB) is an Announcement of Opportunity Instrument for EUMETSAT's Meteosat Second Generation (MSG) satellite. GERB will make accurate measurements of the Earth Radiation Budget from geostationary orbit, provide an absolute reference calibration for LEO Earth radiation budget instruments and allow studies of the energetics of atmospheric processes. By operating from geostationary orbit, measurements may be made many times a day, thereby providing essentially perfect diurnal sampling of the radiation balance between reflected and emitted radiance for that area of the globe within the field of view. GERB will thus complement other instruments which operate in low orbit and give complete global coverage, but with poor and biased time resolution. GERB measures infrared radiation in two wavelength bands: 0.32-4.0 and 0.32- 30 μm, with a pixel element size of 44 km at sub-satellite point. This paper gives an overview of the project and concentrates on the design and development of the instrument and ground testing and calibration, and lessons learnt from a short time scale low-budget project. The instrument was delivered for integration on the MSG platform in April 1999 ready for the proposed launch in October 2000, which has now been delayed probably to early 2002. The ground segment is being undertaken by RAL and RMIB and produces near real-time data for meteorological applications in conjunction with the main MSG imager—SEVERI. Climate research and other applications which are being developed under a EU Framework IV pilot project will be served by fully processed data. Because of the relevance of the observations to climate change, it is planned to maintain an operating instrument in orbit for at least 3.5 years. Two further GERB instruments are being built for subsequent launches of MSG.

  14. Design and implementation of the mobility assessment tool: software description.

    PubMed

    Barnard, Ryan T; Marsh, Anthony P; Rejeski, Walter Jack; Pecorella, Anthony; Ip, Edward H

    2013-07-23

    In previous work, we described the development of an 81-item video-animated tool for assessing mobility. In response to criticism levied during a pilot study of this tool, we sought to develop a new version built upon a flexible framework for designing and administering the instrument. Rather than constructing a self-contained software application with a hard-coded instrument, we designed an XML schema capable of describing a variety of psychometric instruments. The new version of our video-animated assessment tool was then defined fully within the context of a compliant XML document. Two software applications--one built in Java, the other in Objective-C for the Apple iPad--were then built that could present the instrument described in the XML document and collect participants' responses. Separating the instrument's definition from the software application implementing it allowed for rapid iteration and easy, reliable definition of variations. Defining instruments in a software-independent XML document simplifies the process of defining instruments and variations and allows a single instrument to be deployed on as many platforms as there are software applications capable of interpreting the instrument, thereby broadening the potential target audience for the instrument. Continued work will be done to further specify and refine this type of instrument specification with a focus on spurring adoption by researchers in gerontology and geriatric medicine.

  15. An ultraviolet imager to study bright UV sources

    NASA Astrophysics Data System (ADS)

    Mathew, Joice; Prakash, Ajin; Sarpotdar, Mayuresh; Sreejith, A. G.; Safonova, Margarita; Murthy, Jayant

    2016-07-01

    We have designed and developed a compact ultraviolet imaging payload to y on a range of possible platforms such as high altitude balloon experiments, cubesats, space missions, etc. The primary science goals are to study the bright UV sources (mag < 10) and also to look for transients in the Near UV (200 - 300 nm) domain. Our first choice is to place this instrument on a spacecraft going to the Moon as part of the Indian entry into Google lunar X-Prize competition. The major constraints for the instrument are, it should be lightweight (< 2Kg), compact (length < 50cm) and cost effective. The instrument is an 80 mm diameter Cassegrain telescope with a field of view of around half a degree designated for UV imaging. In this paper we will discuss about the various science cases that can be performed by having observations with the instrument on different platforms. We will also describe the design, development and the current state of implementation of the instrument. This includes opto-mechanical and electrical design of the instrument. We have adopted an all spherical optical design which would make the system less complex to realize and a cost effective solution compared to other telescope configuration. The structural design has been chosen in such a way that it will ensure that the instrument could withstand all the launch load vibrations. An FPGA based electronics board is used for the data acquisition, processing and CCD control. We will also brie y discuss about the hardware implementation of the detector interface and algorithms for the detector readout and data processing.

  16. DESDynI Quad First Stage Processor - A Four Channel Digitizer and Digital Beam Forming Processor

    NASA Technical Reports Server (NTRS)

    Chuang, Chung-Lun; Shaffer, Scott; Smythe, Robert; Niamsuwan, Noppasin; Li, Samuel; Liao, Eric; Lim, Chester; Morfopolous, Arin; Veilleux, Louise

    2013-01-01

    The proposed Deformation, Eco-Systems, and Dynamics of Ice Radar (DESDynI-R) L-band SAR instrument employs multiple digital channels to optimize resolution while keeping a large swath on a single pass. High-speed digitization with very fine synchronization and digital beam forming are necessary in order to facilitate this new technique. The Quad First Stage Processor (qFSP) was developed to achieve both the processing performance as well as the digitizing fidelity in order to accomplish this sweeping SAR technique. The qFSP utilizes high precision and high-speed analog to digital converters (ADCs), each with a finely adjustable clock distribution network to digitize the channels at the fidelity necessary to allow for digital beam forming. The Xilinx produced FX130T Virtex 5 part handles the processing to digitally calibrate each channel as well as filter and beam form the receive signals. Demonstrating the digital processing required for digital beam forming and digital calibration is instrumental to the viability of the proposed DESDynI instrument. The qFSP development brings this implementation to Technology Readiness Level (TRL) 6. This paper will detail the design and development of the prototype qFSP as well as the preliminary results from hardware tests.

  17. Applying the Lessons Learned from the HiRISE Ground Data System to the Development of a Modernized GDS for CaSSIS

    NASA Astrophysics Data System (ADS)

    Heyd, R. S.; McArthur, G. A.; Leis, R.; Fennema, A.; Wolf, N.; Schaller, C. J.; Sutton, S.; Plassmann, J.; Forrester, T.; Fine, K.

    2018-04-01

    The HiRISE ground data system is a mature data processing system in operation for over 12 years. The experience gained from this system will be applied to developing a new and more modern GDS to process data from the CaSSIS instrument.

  18. Training Needs Analysis. A Resource for Identifying Training Needs, Selecting Training Strategies, and Developing Training Plans.

    ERIC Educational Resources Information Center

    Bartram, Sharon; Gibson, Brenda

    Designed as a practical tool for trainers, this manual contains 22 instruments and documents for gathering and processing information about training and development issues within an organization. Part one of the two-part manual examines the process of identifying and analyzing training needs. It reviews the different types of information the…

  19. Bottom-up laboratory testing of the DKIST Visible Broadband Imager (VBI)

    NASA Astrophysics Data System (ADS)

    Ferayorni, Andrew; Beard, Andrew; Cole, Wes; Gregory, Scott; Wöeger, Friedrich

    2016-08-01

    The Daniel K. Inouye Solar Telescope (DKIST) is a 4-meter solar observatory under construction at Haleakala, Hawaii [1]. The Visible Broadband Imager (VBI) is a first light instrument that will record images at the highest possible spatial and temporal resolution of the DKIST at a number of scientifically important wavelengths [2]. The VBI is a pathfinder for DKIST instrumentation and a test bed for developing processes and procedures in the areas of unit, systems integration, and user acceptance testing. These test procedures have been developed and repeatedly executed during VBI construction in the lab as part of a "test early and test often" philosophy aimed at identifying and resolving issues early thus saving cost during integration test and commissioning on summit. The VBI team recently completed a bottom up end-to-end system test of the instrument in the lab that allowed the instrument's functionality, performance, and usability to be validated against documented system requirements. The bottom up testing approach includes four levels of testing, each introducing another layer in the control hierarchy that is tested before moving to the next level. First the instrument mechanisms are tested for positioning accuracy and repeatability using a laboratory position-sensing detector (PSD). Second the real-time motion controls are used to drive the mechanisms to verify speed and timing synchronization requirements are being met. Next the high-level software is introduced and the instrument is driven through a series of end-to-end tests that exercise the mechanisms, cameras, and simulated data processing. Finally, user acceptance testing is performed on operational and engineering use cases through the use of the instrument engineering graphical user interface (GUI). In this paper we present the VBI bottom up test plan, procedures, example test cases and tools used, as well as results from test execution in the laboratory. We will also discuss the benefits realized through completion of this testing, and share lessons learned from the bottoms up testing process.

  20. Development and validation of a notational system to study the offensive process in football.

    PubMed

    Sarmento, Hugo; Anguera, Teresa; Campaniço, Jorge; Leitão, José

    2010-01-01

    The most striking change within football development is the application of science to its problems and in particular the use of increasingly sophisticated technology that, supported by scientific data, allows us to establish a "code of reading" the reality of the game. Therefore, this study describes the process of the development and validation of an ad hoc system of categorization, which allows the different methods of offensive game in football and the interaction to be analyzed. Therefore, through an exploratory phase of the study, we identified 10 vertebrate criteria and the respective behaviors observed for each of these criteria. We heard a panel of five experts with the purpose of a content validation. The resulting instrument is characterized by a combination of field formats and systems of categories. The reliability of the instrument was calculated by the intraobserver agreement, and values above 0.95 for all criteria were achieved. Two FC Barcelona games were coded and analyzed, which allowed the detection of various T-patterns. The results show that the instrument serves the purpose for which it was developed and can provide important information for the understanding of game interaction in football.

  1. Development and validation of the pro-environmental behaviour scale for women's health.

    PubMed

    Kim, HyunKyoung

    2017-05-01

    This study was aimed to develop and test the Pro-environmental Behavior Scale for Women's Health. Women adopt sustainable behaviours and alter their life styles to protect the environment and their health from environmental pollution. The conceptual framework of pro-environmental behaviours was based on Rogers' protection motivation theory and Weinstein's precaution adoption process model. The cross-sectional design was used for instrument development. The instrument development process consisted of a literature review, personal depth interviews and focus group interviews. The sample comprised 356 adult women recruited in April-May 2012 in South Korea using quota sampling. For construct validity, exploratory factor analysis was conducted to examine the factor structure, after which convergent and discriminant validity and known-group comparisons were tested. Principal component analysis yielded 17 items with four factors, including 'women's health protection,' 'chemical exposure prevention,' 'alternative consumption,' and 'community-oriented behaviour'. The Cronbach's α was 0·81. Convergent and discriminant validity were supported by performing correlations with other environmental-health and health-behaviour measures. Nursing professionals can reliably use the instrument to assess women's behaviours, which protect their health and the environment. © 2016 John Wiley & Sons Ltd.

  2. DKIST visible broadband imager data processing pipeline

    NASA Astrophysics Data System (ADS)

    Beard, Andrew; Cowan, Bruce; Ferayorni, Andrew

    2014-07-01

    The Daniel K. Inouye Solar Telescope (DKIST) Data Handling System (DHS) provides the technical framework and building blocks for developing on-summit instrument quality assurance and data reduction pipelines. The DKIST Visible Broadband Imager (VBI) is a first light instrument that alone will create two data streams with a bandwidth of 960 MB/s each. The high data rate and data volume of the VBI require near-real time processing capability for quality assurance and data reduction, and will be performed on-summit using Graphics Processing Unit (GPU) technology. The VBI data processing pipeline (DPP) is the first designed and developed using the DKIST DHS components, and therefore provides insight into the strengths and weaknesses of the framework. In this paper we lay out the design of the VBI DPP, examine how the underlying DKIST DHS components are utilized, and discuss how integration of the DHS framework with GPUs was accomplished. We present our results of the VBI DPP alpha release implementation of the calibration, frame selection reduction, and quality assurance display processing nodes.

  3. Cross-cultural validation of instruments measuring health beliefs about colorectal cancer screening among Korean Americans.

    PubMed

    Lee, Shin-Young; Lee, Eunice E

    2015-02-01

    The purpose of this study was to report the instrument modification and validation processes to make existing health belief model scales culturally appropriate for Korean Americans (KAs) regarding colorectal cancer (CRC) screening utilization. Instrument translation, individual interviews using cognitive interviewing, and expert reviews were conducted during the instrument modification phase, and a pilot test and a cross-sectional survey were conducted during the instrument validation phase. Data analyses of the cross-sectional survey included internal consistency and construct validity using exploratory and confirmatory factor analysis. The main issues identified during the instrument modification phase were (a) cultural and linguistic translation issues and (b) newly developed items reflecting Korean cultural barriers. Cross-sectional survey analyses during the instrument validation phase revealed that all scales demonstrate good internal consistency reliability (Cronbach's alpha=.72~.88). Exploratory factor analysis showed that susceptibility and severity loaded on the same factor, which may indicate a threat variable. Items with low factor loadings in the confirmatory factor analysis may relate to (a) lack of knowledge about fecal occult blood testing and (b) multiple dimensions of the subscales. Methodological, sequential processes of instrument modification and validation, including translation, individual interviews, expert reviews, pilot testing and a cross-sectional survey, were provided in this study. The findings indicate that existing instruments need to be examined for CRC screening research involving KAs.

  4. Characterization and measurement of natural gas trace constituents. Volume 1. Arsenic. Final report, June 1989-October 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chao, S.S.; Attari, A.

    1995-01-01

    The discovery of arsenic compounds, as alkylarsines, in natural gas prompted this research program to develop reliable measurement techniques needed to assess the efficiency of removal processes for these environmentally sensitive substances. These techniques include sampling, speciation, quantitation and on-line instrumental methods for monitoring the total arsenic concentration. The current program has yielded many products, including calibration standards, arsenic-specific sorbents, sensitive analytical methods and instrumentation. Four laboratory analytical methods have been developed and successfully employed for arsenic determination in natural gas. These methods use GC-AED and GC-MS instruments to speciate alkylarsines, and peroxydisulfate extraction with FIAS, special carbon sorbent withmore » XRF and an IGT developed sorbent with GFAA for total arsenic measurement.« less

  5. Development of a Chinese medicine assessment measure: an interdisciplinary approach using the delphi method.

    PubMed

    Schnyer, Rosa N; Conboy, Lisa A; Jacobson, Eric; McKnight, Patrick; Goddard, Thomas; Moscatelli, Francesca; Legedza, Anna T R; Kerr, Catherine; Kaptchuk, Ted J; Wayne, Peter M

    2005-12-01

    The diagnostic framework and clinical reasoning process in Chinese medicine emphasizes the contextual and qualitative nature of a patient's illness. Chinese medicine assessment data may help interpret clinical outcomes. As part of a study aimed at assessing the validity and improving the inter-rater reliability of the Chinese diagnostic process, a structured assessment instrument was developed for use in clinical trials of acupuncture and other Chinese medical therapies. To foster collaboration and maximize resources and information, an interdisciplinary advisory team was assembled. Under the guidance of two group process facilitators, and in order to establish whether the assessment instrument was consistent with accepted Chinese medicine diagnostic categories (face validity) and included the full range of each concept's meaning (content validity), a panel of Traditional Chinese Medicine (TCM) expert clinicians was convened and their responses were organized using the Delphi process, an iterative, anonymous, idea-generating and consensus-building process. An aggregate rating measure was obtained by taking the mean of mean ratings for each question across all 10 experts. Over three rounds, the overall rating increased from 7.4 (SD = 1.3) in Round 1 to 9.1 (SD = 0.5) in Round 3. The level of agreement among clinicians was measured by a decrease in SD. The final instrument TEAMSI-TCM (Traditional East Asian Medicine Structured Interview, TCM version) uses the pattern differentiation model characteristic of TCM. This modular, dynamic version was specifically designed to assess women, with a focus on gynecologic conditions; with modifications it can be adapted for use with other populations and conditions. TEAMSI-TCM is a prescriptive instrument that guides clinicians to use the proper indicators, combine them in a systematic manner, and generate conclusions. In conjunction with treatment manualization and training it may serve to increase inter-rater reliability and inter-trial reproducibility in Chinese medicine clinical trials. Testing of the validity and reliability of this instrument currently is underway.

  6. NASA's Experience with UV Remote Using SBUV and TOMS Instruments

    NASA Technical Reports Server (NTRS)

    Bhartia, P. K.

    1999-01-01

    This paper will discuss key features of the NASA algorithm that has been used to produce several highly popular geophysical products from the Solar Backscatter Ultraviolet (SBUV) and Total Ozone Mapping Spectrometer (TOMS) series of instruments. Since these instruments have a limited number of wavelengths, many innovative algorithmic approaches have been developed over the years to derive maximum information from these sensors. We will use Global Ozone Monitoring Experiment (GOME) data to test the assumptions made in these algorithms and show what additional information is contained in the GOME hyperspectral data. At NASA we are using this information to improve the SBUV and TOMS algorithms, as well as to develop more efficient algorithms to process GOME data.

  7. Advances in Field Deployable Instrumented Particles for the Study of Alluvial Transport Mechanisms

    NASA Astrophysics Data System (ADS)

    Dillon, B.; Strom, K.

    2017-12-01

    Advances in microelectromechanical systems (MEMs) in the past decade have lead to the development of various instrumented or "smart" particles for use in the study of alluvial transport. The goal of many of these devices is to collect data on the interaction between hydrodynamic turbulence and individual sediment particles. Studying this interaction provides a basis to better understand entrainment and deposition processes which leads to better predictive morphologic and transport models. In collecting data on these processes, researchers seek to capture the time history of the forces incident on the particle and the particle's reaction. Many methods have been employed to capture this data - miniaturized pressure traps, accelerometers, gyroscopes, MEMs pressure transducers, and cantilevered load cells. However no system to date has been able to capture the pressure forces incident on the particle and its reaction while remaining mobile and of a size and density comparable to most gravels. Advances in the development, deployment, and use of waterproofed laboratory instrumentation have led our research group to develop such a particle. This particle has been used in both laboratory settings and large-scale fluvial environments (coupled with a field-deployable PIV system) to capture data on turbulent erosion processes. This system advances the practice in several ways: 1) It is, at present, the smallest (⌀ 19mm) instrumented erodible particle reported in the literature. 2) It contains novel developments in pressure sensing technology which allow the inclusion of six pressure ports, a 3-axis accelerometer, and a 1-axis gyroscope - all of which can be recorded simultaneously. 3) It expands the researcher's abilities to gather data on phenomena that, previously, have mandated the use of a laboratory scale model. The use of this system has generated observations of the so-called very large scale motions (VLSMs) in a reach of the Virginia section of the New River. Their effects on erosional processes are presented.

  8. Fabrication of capsule assemblies, phase 3

    NASA Technical Reports Server (NTRS)

    Keeton, A. R.; Stemann, L. G.

    1973-01-01

    Thirteen capsule assemblies were fabricated for evaluation of fuel pin design concepts for a fast spectrum lithium cooled compact space power reactor. These instrumented assemblies were designed for real time test of prototype fuel pins. Uranium mononitride fuel pins were encased in AISI 304L stainless steel capsules. Fabrication procedures were fully qualified by process development and assembly qualification tests. Instrumentation reliability was achieved utilizing specially processed and closely controlled thermocouple hot zone fabrication and by thermal screening tests. Overall capsule reliability was achieved with an all electron beam welded assembly.

  9. KSC-02pd0332

    NASA Image and Video Library

    2002-02-28

    VANDENBERG AFB, CALIF. -- The Aqua-EOS satellite is again horizontal for instrument deployment while in the Spaceport Systems International (SSI) payload processing facility on South Vandenberg AFB. Aqua will provide a six year chronology of the planet and its processes. Comprehensive measurements taken by its onboard instruments will allow scientists to assess long-term change, identify its human and natural causes and advance the development of models for long-term forecasting. The Focus for the Aqua Project is the multi-disciplinary study of the Earth's Interrelated Processes (atmosphere, oceans, and land surface) and their relationship to earth system changes. The global change research emphasized with the Aqua instrument data sets include: atmospheric temperature and humidity profiles, clouds, precipitation and radiative balance; terrestrial snow and sea ice; sea surface temperature and ocean productivity; soil moisture; and the improvement of numerical weather prediction. Aqua-EOS is scheduled for launch aboard a Delta II 7920-10L vehicle on April 18, 2002

  10. KSC-02pd0333

    NASA Image and Video Library

    2002-02-28

    VANDENBERG AFB, CALIF. -- Workers in the Spaceport Systems International (SSI) payload processing facility on South Vandenberg AFB work on instrument deployment of the Aqua-EOS satellite. Aqua will provide a six year chronology of the planet and its processes. Comprehensive measurements taken by its onboard instruments will allow scientists to assess long-term change, identify its human and natural causes and advance the development of models for long-term forecasting. The Focus for the Aqua Project is the multi-disciplinary study of the Earth's Interrelated Processes (atmosphere, oceans, and land surface) and their relationship to earth system changes. The global change research emphasized with the Aqua instrument data sets include: atmospheric temperature and humidity profiles, clouds, precipitation and radiative balance; terrestrial snow and sea ice; sea surface temperature and ocean productivity; soil moisture; and the improvement of numerical weather prediction. Aqua-EOS is scheduled for launch aboard a Delta II 7920-10L vehicle on April 18, 2002

  11. Energy Reconstruction for Events Detected in TES X-ray Detectors

    NASA Astrophysics Data System (ADS)

    Ceballos, M. T.; Cardiel, N.; Cobo, B.

    2015-09-01

    The processing of the X-ray events detected by a TES (Transition Edge Sensor) device (such as the one that will be proposed in the ESA AO call for instruments for the Athena mission (Nandra et al. 2013) as a high spectral resolution instrument, X-IFU (Barret et al. 2013)), is a several step procedure that starts with the detection of the current pulses in a noisy signal and ends up with their energy reconstruction. For this last stage, an energy calibration process is required to convert the pseudo energies measured in the detector to the real energies of the incoming photons, accounting for possible nonlinearity effects in the detector. We present the details of the energy calibration algorithm we implemented as the last part of the Event Processing software that we are developing for the X-IFU instrument, that permits the calculation of the calibration constants in an analytical way.

  12. Janus: Graphical Software for Analyzing In-Situ Measurements of Solar-Wind Ions

    NASA Astrophysics Data System (ADS)

    Maruca, B.; Stevens, M. L.; Kasper, J. C.; Korreck, K. E.

    2016-12-01

    In-situ observations of solar-wind ions provide tremendous insights into the physics of space plasmas. Instrument on spacecraft measure distributions of ion energies, which can be processed into scientifically useful data (e.g., values for ion densities and temperatures). This analysis requires a strong, technical understanding of the instrument, so it has traditionally been carried out by the instrument teams using automated software that they had developed for that purpose. The automated routines are optimized for typical solar-wind conditions, so they can fail to capture the complex (and scientifically interesting) microphysics of transient solar-wind - such as coronal mass ejections (CME's) and co-rotating interaction regions (CIR's) - which are often better analyzed manually.This presentation reports on the ongoing development of Janus, a new software package for processing in-situ measurement of solar-wind ions. Janus will provide user with an easy-to-use graphical user interface (GUI) for carrying out highly customized analyses. Transparent to the user, Janus will automatically handle the most technical tasks (e.g., the retrieval and calibration of measurements). For the first time, users with only limited knowledge about the instruments (e.g., non-instrumentalists and students) will be able to easily process measurements of solar-wind ions. Version 1 of Janus focuses specifically on such measurements from the Wind spacecraft's Faraday Cups and is slated for public release in time for this presentation.

  13. PC based PLCs and ethernet based fieldbus: the new standard platform for future VLT instrument control

    NASA Astrophysics Data System (ADS)

    Kiekebusch, Mario J.; Lucuix, Christian; Erm, Toomas M.; Chiozzi, Gianluca; Zamparelli, Michele; Kern, Lothar; Brast, Roland; Pirani, Werther; Reiss, Roland; Popovic, Dan; Knudstrup, Jens; Duchateau, Michel; Sandrock, Stefan; Di Lieto, Nicola

    2014-07-01

    ESO is currently in the final phase of the standardization process for PC-based Programmable Logical Controllers (PLCs) as the new platform for the development of control systems for future VLT/VLTI instruments. The standard solution used until now consists of a Local Control Unit (LCU), a VME-based system having a CPU and commercial and proprietary boards. This system includes several layers of software and many thousands of lines of code developed and maintained in house. LCUs have been used for several years as the interface to control instrument functions but now are being replaced by commercial off-the-shelf (COTS) systems based on BECKHOFF Embedded PCs and the EtherCAT fieldbus. ESO is working on the completion of the software framework that enables a seamless integration into the VLT control system in order to be ready to support upcoming instruments like ESPRESSO and ERIS, that will be the first fully VLT compliant instruments using the new standard. The technology evaluation and standardization process has been a long and combined effort of various engineering disciplines like electronics, control and software, working together to define a solution that meets the requirements and minimizes the impact on the observatory operations and maintenance. This paper presents the challenges of the standardization process and the steps involved in such a change. It provides a technical overview of how industrial standards like EtherCAT, OPC-UA, PLCOpen MC and TwinCAT can be used to replace LCU features in various areas like software engineering and programming languages, motion control, time synchronization and astronomical tracking.

  14. Limited sterile processing capabilities for safe surgery in low-income and middle-income countries: experience in the Republic of Congo, Madagascar and Benin.

    PubMed

    Fast, Olive; Fast, Christina; Fast, Dan; Veltjens, Suzanne; Salami, Zouliha; White, Michelle C

    2017-01-01

    It is highly difficult to perform safe surgery without sterile instruments, yet the capacity to adequately clean, disinfect and sterilise surgical instruments in low-income and middle-income countries is largely unknown. Sterile Processing Education Charitable Trust developed an assessment tool and, in partnership with Mercy Ships, evaluated the sterile processing capacity in 59 facilities in Madagascar, Benin and the Republic of Congo. This data-driven analysis paper illustrates how lack of sterile processing capacity acts as a barrier to safe surgical care. Our tool identified widespread lack of knowledge of techniques and resources needed for sterile processing. Only 12% of workers in Republic of Congo and Benin had sterile processing training and none in Madagascar. None of the hospitals surveyed met basic standards for cleaning, disinfection and sterilisation as defined by the WHO/Pan American Health Organization. Examples of poor practice included lack of cleaning supplies (basic brushes and detergents), incorrect drying and storage of surgical instruments, and inattention to workflow causing cross-contamination. Bleach (sodium hypochlorite) solutions, damaging to instruments, were used universally. In our experience, using an assessment tool allowed identification of specific gaps in sterile processing capacity. Many of the gaps are amenable to simple solutions requiring minimal resources and achievable by most hospitals. We recommend that stakeholders seeking to strengthen surgical health systems in low-resource settings incorporate sterile processing capacity assessments and training into their programmes.

  15. Limited sterile processing capabilities for safe surgery in low-income and middle-income countries: experience in the Republic of Congo, Madagascar and Benin

    PubMed Central

    Fast, Olive; Fast, Christina; Fast, Dan; Veltjens, Suzanne; Salami, Zouliha

    2017-01-01

    It is highly difficult to perform safe surgery without sterile instruments, yet the capacity to adequately clean, disinfect and sterilise surgical instruments in low-income and middle-income countries is largely unknown. Sterile Processing Education Charitable Trust developed an assessment tool and, in partnership with Mercy Ships, evaluated the sterile processing capacity in 59 facilities in Madagascar, Benin and the Republic of Congo. This data-driven analysis paper illustrates how lack of sterile processing capacity acts as a barrier to safe surgical care. Our tool identified widespread lack of knowledge of techniques and resources needed for sterile processing. Only 12% of workers in Republic of Congo and Benin had sterile processing training and none in Madagascar. None of the hospitals surveyed met basic standards for cleaning, disinfection and sterilisation as defined by the WHO/Pan American Health Organization. Examples of poor practice included lack of cleaning supplies (basic brushes and detergents), incorrect drying and storage of surgical instruments, and inattention to workflow causing cross-contamination. Bleach (sodium hypochlorite) solutions, damaging to instruments, were used universally. In our experience, using an assessment tool allowed identification of specific gaps in sterile processing capacity. Many of the gaps are amenable to simple solutions requiring minimal resources and achievable by most hospitals. We recommend that stakeholders seeking to strengthen surgical health systems in low-resource settings incorporate sterile processing capacity assessments and training into their programmes. PMID:29225957

  16. Still at the choice-point: action selection and initiation in instrumental conditioning.

    PubMed

    Balleine, Bernard W; Ostlund, Sean B

    2007-05-01

    Contrary to classic stimulus-response (S-R) theory, recent evidence suggests that, in instrumental conditioning, rats encode the relationship between their actions and the specific consequences that these actions produce. It has remained unclear, however, how encoding this relationship acts to control instrumental performance. Although S-R theories were able to give a clear account of how learning translates into performance, the argument that instrumental learning constitutes the acquisition of information of the form "response R leads to outcome O" does not directly imply a particular performance rule or policy; this information can be used both to perform R and to avoid performing R. Recognition of this problem has forced the development of accounts that allow the O and stimuli that predict the O (i.e., S-O) to play a role in the initiation of specific Rs. In recent experiments, we have used a variety of behavioral procedures in an attempt to isolate the processes that contribute to instrumental performance, including outcome devaluation, reinstatement, and Pavlovian-instrumental transfer. Our results, particularly from experiments assessing outcome-selective reinstatement, suggest that both "feed-forward" (O-R) and "feed-back" (R-O) associations are critical and that although the former appear to be important to response selection, the latter-together with processes that determine outcome value-mediate response initiation. We discuss a conceptual model that integrates these processes and its neural implementation.

  17. Assessing K-5 Teacher Leaders' Mathematical Understanding: What Have the Test Makers and the Test Takers Learned?

    ERIC Educational Resources Information Center

    Ellington, Aimee J.; Whitenack, Joy W.; Inge, Vickie L.; Murray, Megan K.; Schneider, Patti J.

    2012-01-01

    This article describes the design and implementation of an assessment instrument for Numbers and Operations, the first course in a program to train elementary mathematics specialists. We briefly describe the course and its content, and then we elaborate on the process we used to develop the assessment instrument and the corresponding rubric for…

  18. Quantitative Analysis of Heavy Metals in Children's Toys and Jewelry: A Multi-Instrument, Multitechnique Exercise in Analytical Chemistry and Public Health

    ERIC Educational Resources Information Center

    Finch, Lauren E.; Hillyer, Margot M.; Leopold, Michael C.

    2015-01-01

    For most chemistry curricula, laboratory-based activities in quantitative and instrumental analysis continue to be an important aspect of student development/training, one that can be more effective if conceptual understanding is delivered through an inquiry-based process relating the material to relevant issues of public interest and student…

  19. Development of a simulation environment to support intercalibration studies over the Algodones Dunes system

    NASA Astrophysics Data System (ADS)

    Eon, Rehman S.; Gerace, Aaron D.; Montanaro, Matthew; Ambeau, Brittany L.; McCorkel, Joel T.

    2018-01-01

    The ability of sensors to detect changes in the Earth's environment is dependent on retrieving radiometrically consistent and calibrated measurements from its surface. Intercalibration provides consistency among satellite instruments and ensures fidelity of scientific information. Intercalibration is especially important for spaceborne satellites without any on-board calibration, as accuracy of instruments is significantly affected by changes that occur postlaunch. To better understand the key parameters that impact the intercalibration process, this paper describes a simulation environment that was developed to support the primary mission of the Algodones Dunes campaign. Specifically, measurements obtained from the campaign were utilized to create a synthetic landscape to assess the feasibility of using the Algodones Dunes system as an intercalibration site for spaceborne instruments. The impact of two key parameters (differing view-angles and temporal offsets between instruments) on the intercalibration process was assessed. Results of these studies indicate that although the accuracy of intercalibration is sensitive to these parameters, proper knowledge of their impact leads to situations that minimize their effect. This paper concludes with a case study that addresses the feasibility of performing intercalibration on the International Space Station's platform to support NASA's CLARREO, the climate absolute radiance and refractivity observatory, mission.

  20. Massively parallel information processing systems for space applications

    NASA Technical Reports Server (NTRS)

    Schaefer, D. H.

    1979-01-01

    NASA is developing massively parallel systems for ultra high speed processing of digital image data collected by satellite borne instrumentation. Such systems contain thousands of processing elements. Work is underway on the design and fabrication of the 'Massively Parallel Processor', a ground computer containing 16,384 processing elements arranged in a 128 x 128 array. This computer uses existing technology. Advanced work includes the development of semiconductor chips containing thousands of feedthrough paths. Massively parallel image analog to digital conversion technology is also being developed. The goal is to provide compact computers suitable for real-time onboard processing of images.

  1. Development of an instrument to understand the child protective services decision-making process, with a focus on placement decisions.

    PubMed

    Dettlaff, Alan J; Christopher Graham, J; Holzman, Jesse; Baumann, Donald J; Fluke, John D

    2015-11-01

    When children come to the attention of the child welfare system, they become involved in a decision-making process in which decisions are made that have a significant effect on their future and well-being. The decision to remove children from their families is particularly complex; yet surprisingly little is understood about this decision-making process. This paper presents the results of a study to develop an instrument to explore, at the caseworker level, the context of the removal decision, with the objective of understanding the influence of the individual and organizational factors on this decision, drawing from the Decision Making Ecology as the underlying rationale for obtaining the measures. The instrument was based on the development of decision-making scales used in prior decision-making studies and administered to child protection caseworkers in several states. Analyses included reliability analyses, principal components analyses, and inter-correlations among the resulting scales. For one scale regarding removal decisions, a principal components analysis resulted in the extraction of two components, jointly identified as caseworkers' decision-making orientation, described as (1) an internal reference to decision-making and (2) an external reference to decision-making. Reliability analyses demonstrated acceptable to high internal consistency for 9 of the 11 scales. Full details of the reliability analyses, principal components analyses, and inter-correlations among the seven scales are discussed, along with implications for practice and the utility of this instrument to support the understanding of decision-making in child welfare. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Three common faults in current practice that influence the validity of data obtained from electronic air pollution instrumentation.

    PubMed

    Dowd, G; Thomas, R S; Monkman, J L

    1975-01-01

    Instrumental development is now entering a more logical era, where the former artistic character of electronics is being replaced by cold technology. Because of this, one should be expect more reliability; however, there still exist many weak links in practical application. Digital readout systems and computer processing induce a false sense of security. In reality, it is the sample-measurement relationship that determines an instrument's credibility and not the number of digits on its meter. In describing three faulty practices that greatly influence an instrument's performance, it is hoped that measurement may be more closely related to the sample!

  3. Design, Assembly, Integration, and Testing of a Power Processing Unit for a Cylindrical Hall Thruster, the NORSAT-2 Flatsat, and the Vector Gravimeter for Asteroids Instrument Computer

    NASA Astrophysics Data System (ADS)

    Svatos, Adam Ladislav

    This thesis describes the author's contributions to three separate projects. The bus of the NORSAT-2 satellite was developed by the Space Flight Laboratory (SFL) for the Norwegian Space Centre (NSC) and Space Norway. The author's contributions to the mission were performing unit tests for the components of all the spacecraft subsystems as well as designing and assembling the flatsat from flight spares. Gedex's Vector Gravimeter for Asteroids (VEGA) is an accelerometer for spacecraft. The author's contributions to this payload were modifying the instrument computer board schematic, designing the printed circuit board, developing and applying test software, and performing thermal acceptance testing of two instrument computer boards. The SFL's cylindrical Hall effect thruster combines the cylindrical configuration for a Hall thruster and uses permanent magnets to achieve miniaturization and low power consumption, respectively. The author's contributions were to design, build, and test an engineering model power processing unit.

  4. Development of a student-centered instrument to assess middle school students' conceptual understanding of sound

    NASA Astrophysics Data System (ADS)

    Eshach, Haim

    2014-06-01

    This article describes the development and field test of the Sound Concept Inventory Instrument (SCII), designed to measure middle school students' concepts of sound. The instrument was designed based on known students' difficulties in understanding sound and the history of science related to sound and focuses on two main aspects of sound: sound has material properties, and sound has process properties. The final SCII consists of 71 statements that respondents rate as either true or false and also indicate their confidence on a five-point scale. Administration to 355 middle school students resulted in a Cronbach alpha of 0.906, suggesting a high reliability. In addition, the average percentage of students' answers to statements that associate sound with material properties is significantly higher than the average percentage of statements associating sound with process properties (p <0.001). The SCII is a valid and reliable tool that can be used to determine students' conceptions of sound.

  5. A framework for assessing Health Economic Evaluation (HEE) quality appraisal instruments.

    PubMed

    Langer, Astrid

    2012-08-16

    Health economic evaluations support the health care decision-making process by providing information on costs and consequences of health interventions. The quality of such studies is assessed by health economic evaluation (HEE) quality appraisal instruments. At present, there is no instrument for measuring and improving the quality of such HEE quality appraisal instruments. Therefore, the objectives of this study are to establish a framework for assessing the quality of HEE quality appraisal instruments to support and improve their quality, and to apply this framework to those HEE quality appraisal instruments which have been subject to more scrutiny than others, in order to test the framework and to demonstrate the shortcomings of existing HEE quality appraisal instruments. To develop the quality assessment framework for HEE quality appraisal instruments, the experiences of using appraisal tools for clinical guidelines are used. Based on a deductive iterative process, clinical guideline appraisal instruments identified through literature search are reviewed, consolidated, and adapted to produce the final quality assessment framework for HEE quality appraisal instruments. The final quality assessment framework for HEE quality appraisal instruments consists of 36 items organized within 7 dimensions, each of which captures a specific domain of quality. Applying the quality assessment framework to four existing HEE quality appraisal instruments, it is found that these four quality appraisal instruments are of variable quality. The framework described in this study should be regarded as a starting point for appraising the quality of HEE quality appraisal instruments. This framework can be used by HEE quality appraisal instrument producers to support and improve the quality and acceptance of existing and future HEE quality appraisal instruments. By applying this framework, users of HEE quality appraisal instruments can become aware of methodological deficiencies inherent in existing HEE quality appraisal instruments. These shortcomings of existing HEE quality appraisal instruments are illustrated by the pilot test.

  6. A framework for assessing Health Economic Evaluation (HEE) quality appraisal instruments

    PubMed Central

    2012-01-01

    Background Health economic evaluations support the health care decision-making process by providing information on costs and consequences of health interventions. The quality of such studies is assessed by health economic evaluation (HEE) quality appraisal instruments. At present, there is no instrument for measuring and improving the quality of such HEE quality appraisal instruments. Therefore, the objectives of this study are to establish a framework for assessing the quality of HEE quality appraisal instruments to support and improve their quality, and to apply this framework to those HEE quality appraisal instruments which have been subject to more scrutiny than others, in order to test the framework and to demonstrate the shortcomings of existing HEE quality appraisal instruments. Methods To develop the quality assessment framework for HEE quality appraisal instruments, the experiences of using appraisal tools for clinical guidelines are used. Based on a deductive iterative process, clinical guideline appraisal instruments identified through literature search are reviewed, consolidated, and adapted to produce the final quality assessment framework for HEE quality appraisal instruments. Results The final quality assessment framework for HEE quality appraisal instruments consists of 36 items organized within 7 dimensions, each of which captures a specific domain of quality. Applying the quality assessment framework to four existing HEE quality appraisal instruments, it is found that these four quality appraisal instruments are of variable quality. Conclusions The framework described in this study should be regarded as a starting point for appraising the quality of HEE quality appraisal instruments. This framework can be used by HEE quality appraisal instrument producers to support and improve the quality and acceptance of existing and future HEE quality appraisal instruments. By applying this framework, users of HEE quality appraisal instruments can become aware of methodological deficiencies inherent in existing HEE quality appraisal instruments. These shortcomings of existing HEE quality appraisal instruments are illustrated by the pilot test. PMID:22894708

  7. Adaptation of a nursing home culture change research instrument for frontline staff quality improvement use.

    PubMed

    Hartmann, Christine W; Palmer, Jennifer A; Mills, Whitney L; Pimentel, Camilla B; Allen, Rebecca S; Wewiorski, Nancy J; Dillon, Kristen R; Snow, A Lynn

    2017-08-01

    Enhanced interpersonal relationships and meaningful resident engagement in daily life are central to nursing home cultural transformation, yet these critical components of person-centered care may be difficult for frontline staff to measure using traditional research instruments. To address the need for easy-to-use instruments to help nursing home staff members evaluate and improve person-centered care, the psychometric method of cognitive-based interviewing was used to adapt a structured observation instrument originally developed for researchers and nursing home surveyors. Twenty-eight staff members from 2 Veterans Health Administration (VHA) nursing homes participated in 1 of 3 rounds of cognitive-based interviews, using the instrument in real-life situations. Modifications to the original instrument were guided by a cognitive processing model of instrument refinement. Following 2 rounds of cognitive interviews, pretesting of the revised instrument, and another round of cognitive interviews, the resulting set of 3 short instruments mirrored the concepts of the original longer instrument but were significantly easier for frontline staff to understand and use. Final results indicated frontline staff found the revised instruments feasible to use and clinically relevant in measuring and improving the lived experience of a changing culture. This article provides a framework for developing or adapting other measurement tools for frontline culture change efforts in nursing homes, in addition to reporting on a practical set of instruments to measure aspects of person-centered care. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  8. Development and testing of the Youth Alcohol Norms Survey (YANS) instrument to measure youth alcohol norms and psychosocial influences

    PubMed Central

    Maycock, Bruce; Hildebrand, Janina; Zhao, Yun; Allsop, Steve; Lobo, Roanna; Howat, Peter

    2018-01-01

    Objectives This study aimed to develop and validate an online instrument to: (1) identify common alcohol-related social influences, norms and beliefs among adolescents; (2) clarify the process and pathways through which proalcohol norms are transmitted to adolescents; (3) describe the characteristics of social connections that contribute to the transmission of alcohol norms; and (4) identify the influence of alcohol marketing on adolescent norm development. Setting The online Youth Alcohol Norms Survey (YANS) was administered in secondary schools in Western Australia Participants Using a 2-week test–retest format, the YANS was administered to secondary school students (n=481, age=13–17 years, female 309, 64.2%). Primary and secondary outcome measures The development of the YANS was guided by social cognitive theory and comprised a systematic multistage process including evaluation of content and face validity. A 2-week test–retest format was employed. Exploratory factor analysis was conducted to determine the underlying factor structure of the instrument. Test–retest reliability was examined using intraclass correlation coefficient (ICC) and Cohen’s kappa. Results A five-factor structure with meaningful components and robust factorial loads was identified, and the five factors were labelled as ‘individual attitudes and beliefs’, ‘peer and community identity’, ‘sibling influences’, ‘school and community connectedness’ and ‘injunctive norms’, respectively. The instrument demonstrated stability across the test–retest procedure (ICC=0.68–0.88, Cohen’s kappa coefficient=0.69) for most variables. Conclusions The results support the reliability and factorial validity of this instrument. The YANS presents a promising tool, which enables comprehensive assessment of reciprocal individual, behavioural and environmental factors that influence alcohol-related norms among adolescents. PMID:29764872

  9. Development and testing of the Youth Alcohol Norms Survey (YANS) instrument to measure youth alcohol norms and psychosocial influences.

    PubMed

    Burns, Sharyn K; Maycock, Bruce; Hildebrand, Janina; Zhao, Yun; Allsop, Steve; Lobo, Roanna; Howat, Peter

    2018-05-14

    This study aimed to develop and validate an online instrument to: (1) identify common alcohol-related social influences, norms and beliefs among adolescents; (2) clarify the process and pathways through which proalcohol norms are transmitted to adolescents; (3) describe the characteristics of social connections that contribute to the transmission of alcohol norms; and (4) identify the influence of alcohol marketing on adolescent norm development. The online Youth Alcohol Norms Survey (YANS) was administered in secondary schools in Western Australia PARTICIPANTS: Using a 2-week test-retest format, the YANS was administered to secondary school students (n=481, age=13-17 years, female 309, 64.2%). The development of the YANS was guided by social cognitive theory and comprised a systematic multistage process including evaluation of content and face validity. A 2-week test-retest format was employed. Exploratory factor analysis was conducted to determine the underlying factor structure of the instrument. Test-retest reliability was examined using intraclass correlation coefficient (ICC) and Cohen's kappa. A five-factor structure with meaningful components and robust factorial loads was identified, and the five factors were labelled as 'individual attitudes and beliefs', 'peer and community identity', 'sibling influences', 'school and community connectedness' and 'injunctive norms', respectively. The instrument demonstrated stability across the test-retest procedure (ICC=0.68-0.88, Cohen's kappa coefficient=0.69) for most variables. The results support the reliability and factorial validity of this instrument. The YANS presents a promising tool, which enables comprehensive assessment of reciprocal individual, behavioural and environmental factors that influence alcohol-related norms among adolescents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Design and implementation of the mobility assessment tool: software description

    PubMed Central

    2013-01-01

    Background In previous work, we described the development of an 81-item video-animated tool for assessing mobility. In response to criticism levied during a pilot study of this tool, we sought to develop a new version built upon a flexible framework for designing and administering the instrument. Results Rather than constructing a self-contained software application with a hard-coded instrument, we designed an XML schema capable of describing a variety of psychometric instruments. The new version of our video-animated assessment tool was then defined fully within the context of a compliant XML document. Two software applications—one built in Java, the other in Objective-C for the Apple iPad—were then built that could present the instrument described in the XML document and collect participants’ responses. Separating the instrument’s definition from the software application implementing it allowed for rapid iteration and easy, reliable definition of variations. Conclusions Defining instruments in a software-independent XML document simplifies the process of defining instruments and variations and allows a single instrument to be deployed on as many platforms as there are software applications capable of interpreting the instrument, thereby broadening the potential target audience for the instrument. Continued work will be done to further specify and refine this type of instrument specification with a focus on spurring adoption by researchers in gerontology and geriatric medicine. PMID:23879716

  11. Assessment of the Use of Online Comunities to Integrate Educational Processes Development Teams: An Experience in Popular Health Education in Brazil

    ERIC Educational Resources Information Center

    Barilli, Elomar Castilho; de Freitas Barretto, Stenio; Lima, Carla Moura; Menezes, Marco Antonio

    2014-01-01

    This paper is intended to share the results of the assessment of the use of the Online Work Community (OWC), developed in the Moodle technology that was used as an instrument to facilitate the educational and operational processes, intended to share problems and proposals for solution among the 470 members of the development teams, made up of…

  12. Assessing Christian-Faith and Cognitive Development in College Students: CFCDS Instrument Development

    ERIC Educational Resources Information Center

    Foote, Laura S.

    2013-01-01

    What happens when students go to college? An important outcome of college attendance is student cognitive development. Part of that developmental process is learning how to address contrasting values, beliefs, knowledge structures, and worldviews critically. This study addressed the relationship between cognitive and Christian-faith development in…

  13. Analysis on detection accuracy of binocular photoelectric instrument optical axis parallelism digital calibration instrument

    NASA Astrophysics Data System (ADS)

    Ying, Jia-ju; Yin, Jian-ling; Wu, Dong-sheng; Liu, Jie; Chen, Yu-dan

    2017-11-01

    Low-light level night vision device and thermal infrared imaging binocular photoelectric instrument are used widely. The maladjustment of binocular instrument ocular axises parallelism will cause the observer the symptom such as dizziness, nausea, when use for a long time. Binocular photoelectric equipment digital calibration instrument is developed for detecting ocular axises parallelism. And the quantitative value of optical axis deviation can be quantitatively measured. As a testing instrument, the precision must be much higher than the standard of test instrument. Analyzes the factors that influence the accuracy of detection. Factors exist in each testing process link which affect the precision of the detecting instrument. They can be divided into two categories, one category is factors which directly affect the position of reticle image, the other category is factors which affect the calculation the center of reticle image. And the Synthesize error is calculated out. And further distribute the errors reasonably to ensure the accuracy of calibration instruments.

  14. Trainees' Perceptions of Feedback: Validity Evidence for Two FEEDME (Feedback in Medical Education) Instruments.

    PubMed

    Bing-You, Robert; Ramesh, Saradha; Hayes, Victoria; Varaklis, Kalli; Ward, Denham; Blanco, Maria

    2018-01-01

    Construct: Medical educators consider feedback a core component of the educational process. Effective feedback allows learners to acquire new skills, knowledge, and attitudes. Learners' perceptions of feedback are an important aspect to assess with valid methods in order to improve the feedback skills of educators and the feedback culture. Although guidelines for delivering effective feedback have existed for several decades, medical students and residents often indicate that they receive little feedback. A recent scoping review on feedback in medical education did not reveal any validity evidence on instruments to assess learner's perceptions of feedback. The purpose of our study was to gather validity evidence on two novel FEEDME (Feedback in Medical Education) instruments to assess medical students' and residents' perceptions of the feedback that they receive. After the authors developed an initial instrument with 54 items, cognitive interviews with medical students and residents suggested that 2 separate instruments were needed, one focused on the feedback culture (FEEDME-Culture) and the other on the provider of feedback (FEEDME-Provider). A Delphi study with 17 medical education experts and faculty members assessed content validity. The response process was explored involving 31 medical students and residents at 2 academic institutions. Exploratory factor analysis and reliability analyses were performed on completed instruments. Two Delphi consultation rounds refined the wording of items and eliminated several items. Learners found both instruments easy and quick to answer; it took them less than 5 minutes to complete. Learners preferred an electronic format of the instruments over paper. Factor analysis revealed a two- and three-factor solution for the FEEDME-Culture and FEEDME-Provider instruments, respectively. Cronbach's alpha was greater than 0.80 for all factors. Items on both instruments were moderately to highly correlated (range, r = .3-.7). Our results provide preliminary validity evidence of 2 novel feedback instruments. After further validation of both FEEDME instruments, sharing the results of the FEEDME-Culture instrument with educational leaders and faculty may improve the culture of feedback on specific educational rotations and at the institutional level. The FEEDME-Provider instrument could be useful for faculty development targeting feedback skills. Additional research studies could assess whether both instruments may be used to help learners receive feedback and prompt reflective learning.

  15. Harsh Environment Silicon Carbide Sensor Technology for Geothermal Instrumentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pisano, Albert P.

    2013-04-26

    This project utilizes Silicon Carbide (SiC) materials platform to fabricate advanced sensors to be used as high-temperature downhole instrumentation for the DOE’s Geothermal Technologies Program on Enhanced Geothermal Systems. The scope of the proposed research is to 1) develop a SiC pressure sensor that can operate in harsh supercritical conditions, 2) develop a SiC temperature sensor that can operate in harsh supercritical conditions, 3) develop a bonding process for adhering SiC sensor die to well casing couplers, and 4) perform experimental exposure testing of sensor materials and the sensor devices.

  16. Advances in Projection Moire Interferometry Development for Large Wind Tunnel Applications

    NASA Technical Reports Server (NTRS)

    Fleming, Gary A.; Soto, Hector L.; South, Bruce W.; Bartram, Scott M.

    1999-01-01

    An instrument development program aimed at using Projection Moire Interferometry (PMI) for acquiring model deformation measurements in large wind tunnels was begun at NASA Langley Research Center in 1996. Various improvements to the initial prototype PMI systems have been made throughout this development effort. This paper documents several of the most significant improvements to the optical hardware and image processing software, and addresses system implementation issues for large wind tunnel applications. The improvements have increased both measurement accuracy and instrument efficiency, promoting the routine use of PMI for model deformation measurements in production wind tunnel tests.

  17. Optics for Processes, Products and Metrology

    NASA Astrophysics Data System (ADS)

    Mather, George

    1999-04-01

    Optical physics has a variety of applications in industry, including process inspection, coatings development, vision instrumentation, spectroscopy, and many others. Optics has been used extensively in the design of solar energy collection systems and coatings, for example. Also, with the availability of good CCD cameras and fast computers, it has become possible to develop real-time inspection and metrology devices that can accommodate the high throughputs encountered in modern production processes. More recently, developments in moiré interferometry show great promise for applications in the basic metals and electronics industries. The talk will illustrate applications of optics by discussing process inspection techniques for defect detection, part dimensioning, birefringence measurement, and the analysis of optical coatings in the automotive, glass, and optical disc industries. In particular, examples of optical techniques for the quality control of CD-R, MO, and CD-RW discs will be presented. In addition, the application of optical concepts to solar energy collector design and to metrology by moiré techniques will be discussed. Finally, some of the modern techniques and instruments used for qualitative and quantitative material analysis will be presented.

  18. [An overview of telehealth initiatives in Latin America].

    PubMed

    dos Santos, Alaneir de Fátima; D'Agostino, Marcelo; Bouskela, Maurício Simon; Fernandéz, Andrés; Messina, Luiz Ary; Alves, Humberto José

    2014-01-01

    This article aimed to systematize the views on telehealth in Latin America and to present the experience of building an instrument for monitoring the development of telehealth initiatives based on the reality of this region. A group was structured to coordinate telehealth efforts in Latin America, with members appointed by the ministries of health of 16 countries. Five thematic groups were also set up. Based on international experiences and focusing on the reality of telehealth in the continent, an instrument was created to monitor the development of telehealth in Latin America. Several countries have national telehealth projects: Brazil, Colombia, Ecuador, Mexico, Panama. Others are in the process of development and early deployment: Bolivia, Costa Rica, Cuba, El Salvador, Guatemala, Peru, Venezuela. The instrument described in the article, which is still being tested, proposes a characterization of countries according to their telehealth development stage: nonexistent, nascent, intermediate, advanced, and exemplary. Currently, important telehealth initiatives are already underway in Latin America.

  19. Corrosion of Highly Specular Vapor Deposited Aluminum (VDA) on Earthshade Door Sandwich Structure

    NASA Technical Reports Server (NTRS)

    Plaskon, Daniel; Hsieh, Cheng

    2003-01-01

    High-resolution infrared (IR) imaging requires spacecraft instrument design that is tightly coupled with overall thermal control design. The JPL Tropospheric Emission Spectrometer (TES) instrument measures the 3-dimensional distribution of ozone and its precursors in the lower atmosphere on a global scale. The TES earthshade must protect the 180-K radiator and the 230-K radiator from the Earth IR and albedo. Requirements for specularity, emissivity, and solar absorptance of inner surfaces could only be met with vapor deposited aluminum (VDA). Circumstances leading to corrosion of the VDA are described. Innovative materials and processing to meet the optical and thermal cycle requirements were developed. Examples of scanning electronmicroscope (SEM), atomic force microscope (AFM), and other surface analysis techniques used in failure analysis, problem solving, and process development are given. Materials and process selection criteria and development test results are presented in a decision matrix. Examples of conditions promoting and preventing galvanic corrosion between VDA and graphite fiber-reinforced laminates are provided.

  20. Hormone Purification by Isoelectric Focusing

    NASA Technical Reports Server (NTRS)

    Bier, M.

    1985-01-01

    Various ground-based research approaches are being applied to a more definitive evaluation of the natures and degrees of electroosmosis effects on the separation capabilities of the Isoelectric Focusing (IEF) process. A primary instrumental system for this work involves rotationally stabilized, horizontal electrophoretic columns specially adapted for the IEF process. Representative adaptations include segmentation, baffles/screens, and surface coatings. Comparative performance and development testing are pursued against the type of column or cell established as an engineering model. Previously developed computer simulation capabilities are used to predict low-gravity behavior patterns and performance for IEF apparatus geometries of direct project interest. Three existing mathematical models plus potential new routines for particular aspects of simulating instrument fluid patterns with varied wall electroosmosis influences are being exercised.

  1. A behaviourally anchored rating scale for evaluating the use of the WHO surgical safety checklist: development and initial evaluation of the WHOBARS.

    PubMed

    Devcich, Daniel A; Weller, Jennifer; Mitchell, Simon J; McLaughlin, Scott; Barker, Lauren; Rudolph, Jenny W; Raemer, Daniel B; Zammert, Martin; Singer, Sara J; Torrie, Jane; Frampton, Chris Ma; Merry, Alan F

    2016-10-01

    Realising the full potential of the WHO Surgical Safety Checklist (SSC) to reduce perioperative harm requires the constructive engagement of all operating room (OR) team members during its administration. To facilitate research on SSC implementation, a valid and reliable instrument is needed for measuring OR team behaviours during its administration. We developed a behaviourally anchored rating scale (BARS) for this purpose. We used a modified Delphi process, involving 16 subject matter experts, to compile a BARS with behavioural domains applicable to all three phases of the SSC. We evaluated the instrument in 80 adult OR cases and 30 simulated cases using two medical student raters and seven expert raters, respectively. Intraclass correlation coefficients were calculated to assess inter-rater reliability. Internal consistency and instrument discrimination were explored. Sample size estimates for potential study designs using the instrument were calculated. The Delphi process resulted in a BARS instrument (the WHOBARS) with five behavioural domains. Intraclass correlation coefficients calculated from the OR cases exceeded 0.80 for 80% of the instrument's domains across the SSC phases. The WHOBARS showed high internal consistency across the three phases of the SSC and ability to discriminate among surgical cases in both clinical and simulated settings. Fewer than 20 cases per group would be required to show a difference of 1 point between groups in studies of the SSC, where α=0.05 and β=0.8. We have developed a generic instrument for comprehensively rating the administration of the SSC and informing initiatives to realise its full potential. We have provided data supporting its capacity for discrimination, internal consistency and inter-rater reliability. Further psychometric evaluation is warranted. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. Developing a Survey Instrument for Evaluating the Effectiveness of Data Management Training Materials

    NASA Astrophysics Data System (ADS)

    Hou, C. Y.; Soyka, H.; Hutchison, V.; Budden, A. E.

    2016-12-01

    Education and training resources that focus on best practices and guidelines for working with data such as: data management, data sharing, quality metadata creation, and maintenance for reuse, have vital importance not only to the users of Data Observation Network for Earth (DataONE), but also to the broader scientific, research, and academic communities. However, creating and maintaining relevant training/educational materials that remain sensitive and responsive to community needs is dependent upon careful evaluations of the current landscape in order to promote and support thoughtful development of new resources. Using DataONE's existing training/educational resources as the basis for this project, the authors have worked to develop an evaluation instrument that can be used to evaluate the effectiveness of data management training/education resources. The evaluation instrument is in the form of a digital questionnaire/survey. The evaluation instrument also includes the structure and content as recommended by the best practices/guidelines of questionnaire/survey design, based on a review of the literature. Additionally, the evaluation instrument can be customized to evaluate various training/education modalities and be implemented using a web-based questionnaire/survey platform. Finally, the evaluation instrument can be used for site-wide evaluation of DataONE teaching materials and resources, and once made publicly available and openly accessible, other organizations may also utilize the instrument. One key outcome of developing the evaluation instrument is to help in increasing the effectiveness of data management training/education resources across the Earth/Geoscience community. Through this presentation, the authors will provide the full background and motivations for creating an instrument for evaluating the effectiveness of data management training/education resources. The presentation will also discuss in detail the process and results of the current version of the evaluation instrument. Finally, the presentation will highlight the key features and the next steps to examine in order to improve the next revisions of the instrument.

  3. Chemometric aided NIR portable instrument for rapid assessment of medicine quality.

    PubMed

    Zontov, Y V; Balyklova, K S; Titova, A V; Rodionova, O Ye; Pomerantsev, A L

    2016-11-30

    The progress in instrumentation technology has led to miniaturization of NIR instruments. Fast systems that contain no moving parts were developed to be used in the field, warehouses, drugstores, etc. At the same time, in general these portable/handheld spectrometers have a lower spectral resolution and a narrower spectral region than stationary ones. Vendors of portable instruments supply their equipment with special software for spectra processing, which aims at simplifying the analyst's work to the highest degree possible. Often such software is not fully capable of solving complex problems. In application to a real-world problem of counterfeit drug detection we demonstrate that even impaired spectral data do carry information sufficient for drug authentication. The chemometrics aided approach helps to extract this information and thus to extend the applicability of miniaturized NIR instruments. MicroPhazir-RX NIR spectrometer is used as an example of a portable instrument. The data driven soft independent modeling of class analogy (DD-SIMCA) method is employed for data processing. A representative set of tablets of a calcium channel blocker from 6 different manufacturers is used to illustrate the proposed approach. It is shown that the DD-SIMCA approach yields a better result than the basic method provided by the instrument vendor. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Regional Centre of Expertise (RCE) Graz-Styria: A Process of Mobilization Facing Regional Challenges

    ERIC Educational Resources Information Center

    Mader, Clemens; Zimmermann, Friedrich M.; Steiner, Gerald; Risopoulos, Filippina

    2008-01-01

    Purpose: The purpose of this paper is to present how the Regional Centres of Expertise (RCE) Graz-Styria as well as RCEs as instruments can contribute to regional development. The RCE Graz-Styria is representing a case study of Central European RCEs. Design/methodology/approach: The paper describes the development process of RCE Graz-Styria.…

  5. An Evaluation of the Employee Training and Development Process for Nicolet Area Technical College's Basic Education Program.

    ERIC Educational Resources Information Center

    Karl, Luis C.

    The adult basic education (ABE) program at Nicolet Area Technical College (NATC) evaluated its training and development (T&D) process for new basic education instructors. The study gathered monitoring and screening criteria that addressed valuable components for use in an instrument for validating effectiveness of the ABE program (T&D)…

  6. Development and psychometric testing of the nursing student mentors' competence instrument (MCI): A cross-sectional study.

    PubMed

    Tuomikoski, Anna-Maria; Ruotsalainen, Heidi; Mikkonen, Kristina; Miettunen, Jouko; Kääriäinen, Maria

    2018-06-05

    Mentors require competence at a diverse array of skills to mentor students during clinical practice. According to the latest evidence, competence at mentoring includes: knowledge, skills and attributes of individual students' learning objectives, core elements of nursing, learning processes, a reciprocal and trustful relationship, feedback, evaluation, cooperation with stakeholders, and the mentor's personal qualities. The purpose of the study was to test psychometric properties of a mentor's competence instrument developed to self-evaluate mentors' competence at mentoring nursing students in clinical practice. A cross-sectional, descriptive, explorative study design was used. Data were collected from mentors at five university hospitals in Finland in 2016. A total of 576 mentors participated in this study. The instrument was developed through systematic review, experts' evaluations, and pilot versions of the instrument tested in previous studies. The construct validity and reliability of the instrument were tested using exploratory factor analysis (EFA) with promax rotation and Cronbach's alpha. A 10-factor model showed that the instrument has acceptable construct validity. Cronbach's alpha values for the subscales observed ranged from 0.76 to 0.90. The instrument exhibited acceptable psychometric properties, thereby proving itself a valuable tool for evaluating mentors' competence at mentoring students. Further assessments of its reliability, validity and generality for measuring mentor's competence for mentoring students in different contexts and cultures are recommended. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Materials for VPHGs: practical considerations in the case of astronomical instrumentation

    NASA Astrophysics Data System (ADS)

    Bianco, Andrea; Pariani, Giorgio; Zanutta, Alessio; Bertarelli, Chiara

    2012-09-01

    Volume Phase Holographic Gratings are interesting dispersing elements for astronomical instrumentation. An important point, in the realization of the grating, is the choice of the holographic material. Dichromated Gelatines (DCGs) are the best candidate, but they show some drawback especially regarding their water sensitivity and the complex developing process required to enhance their performances. New holographic materials are becoming interesting, such as photopolymers and photochromic materials. An exhaustive review of these classes of materials will be reported and their performances compared to those of DCGs, focusing mainly to the astronomical instrumentation field.

  8. Effectiveness of Teamwork in an Integrated Care Setting for Patients with COPD: Development and Testing of a Self-Evaluation Instrument for Interprofessional Teams

    PubMed Central

    Van Dijk-de Vries, Anneke N.; Duimel-Peeters, Inge G. P.; Muris, Jean W.; Wesseling, Geertjan J.; Beusmans, George H. M. I.

    2016-01-01

    Introduction: Teamwork between healthcare providers is conditional for the delivery of integrated care. This study aimed to assess the usefulness of the conceptual framework Integrated Team Effectiveness Model for developing and testing of the Integrated Team Effectiveness Instrument. Theory and methods: Focus groups with healthcare providers in an integrated care setting for people with chronic obstructive pulmonary disease (COPD) were conducted to examine the recognisability of the conceptual framework and to explore critical success factors for collaborative COPD practice out of this framework. The resulting items were transposed into a pilot instrument. This was reviewed by expert opinion and completed 153 times by healthcare providers. The underlying structure and internal consistency of the instrument were verified by factor analysis and Cronbach’s alpha. Results: The conceptual framework turned out to be comprehensible for discussing teamwork effectiveness. The pilot instrument measures 25 relevant aspects of teamwork in integrated COPD care. Factor analysis suggested three reliable components: teamwork effectiveness, team processes and team psychosocial traits (Cronbach’s alpha between 0.76 and 0.81). Conclusions and discussion: The conceptual framework Integrated Team Effectiveness Model is relevant in developing a practical full-spectrum instrument to facilitate discussing teamwork effectiveness. The Integrated Team Effectiveness Instrument provides a well-founded basis to self-evaluate teamwork effectiveness in integrated COPD care by healthcare providers. Recommendations are provided for the improvement of the instrument. PMID:27616953

  9. Measuring the Process and Quality of Informed Consent for Clinical Research: Development and Testing

    PubMed Central

    Cohn, Elizabeth Gross; Jia, Haomiao; Smith, Winifred Chapman; Erwin, Katherine; Larson, Elaine L.

    2013-01-01

    Purpose/Objectives To develop and assess the reliability and validity of an observational instrument, the Process and Quality of Informed Consent (P-QIC). Design A pilot study of the psychometrics of a tool designed to measure the quality and process of the informed consent encounter in clinical research. The study used professionally filmed, simulated consent encounters designed to vary in process and quality. Setting A major urban teaching hospital in the northeastern region of the United States. Sample 63 students enrolled in health-related programs participated in psychometric testing, 16 students participated in test-retest reliability, and 5 investigator-participant dyads were observed for the actual consent encounters. Methods For reliability and validity testing, students watched and rated videotaped simulations of four consent encounters intentionally varied in process and content and rated them with the proposed instrument. Test-retest reliability was established by raters watching the videotaped simulations twice. Inter-rater reliability was demonstrated by two simultaneous but independent raters observing an actual consent encounter. Main Research Variables The essential elements of information and communication for informed consent. Findings The initial testing of the P-QIC demonstrated reliable and valid psychometric properties in both the simulated standardized consent encounters and actual consent encounters in the hospital setting. Conclusions The P-QIC is an easy-to-use observational tool that provides a quick assessment of the areas of strength and areas that need improvement in a consent encounter. It can be used in the initial trainings of new investigators or consent administrators and in ongoing programs of improvement for informed consent. Implications for Nursing The development of a validated observational instrument will allow investigators to assess the consent process more accurately and evaluate strategies designed to improve it. PMID:21708532

  10. Development of Assessment Instrument of Critical Thinking in Physics at Senior High School

    NASA Astrophysics Data System (ADS)

    Sugiarti, T.; Kaniawati, I.; Aviyanti, L.

    2017-02-01

    The result of preliminary study shows that the assessment of physics in school did not train students’ critical thinking skill. The assessment instrument just measured low cognitive aspects. Supposedly, critical thinking skill is trained in the assessment activity. The study aims to determine the characteristics and the quality of critical thinking skill instrument. It employs descriptive-qualitative method with research and development as the research design. The research participants are 35 students involved in the limited trial and 188 students in the wider trial from three public senior high school in Ciamis which in high level school. The data was collected through expert validation, tests and interviews. The results indicate that the characteristics of the assessment instrument of critical thinking skill is open-ended. The instrument fulfills some indicators namely analyzing argument, deduction, induction, and display information in the form of scenario, text, graphic and table. In addition, the data processing through V4 Anates program shows that the instrument reliability achieves 0.67 with high interpretation of 0.67 and the validity is 0.47 with enough interpretation. Thus, the assessment instrument of critical thinking skill in the form of open-ended essay meets the criteria of quality test, so it can use as instrument of assessment critical thinking skill.

  11. Implementation of microchip electrophoresis instrumentation for future spaceflight missions.

    PubMed

    Willis, Peter A; Creamer, Jessica S; Mora, Maria F

    2015-09-01

    We present a comprehensive discussion of the role that microchip electrophoresis (ME) instrumentation could play in future NASA missions of exploration, as well as the current barriers that must be overcome to make this type of chemical investigation possible. We describe how ME would be able to fill fundamental gaps in our knowledge of the potential for past, present, or future life beyond Earth. Despite the great promise of ME for ultrasensitive portable chemical analysis, to date, it has never been used on a robotic mission of exploration to another world. We provide a current snapshot of the technology readiness level (TRL) of ME instrumentation, where the TRL is the NASA systems engineering metric used to evaluate the maturity of technology, and its fitness for implementation on missions. We explain how the NASA flight implementation process would apply specifically to ME instrumentation, and outline the scientific and technology development issues that must be addressed for ME analyses to be performed successfully on another world. We also outline research demonstrations that could be accomplished by independent researchers to help advance the TRL of ME instrumentation for future exploration missions. The overall approach described here for system development could be readily applied to a wide range of other instrumentation development efforts having broad societal and commercial impact.

  12. Berend Wilken: A Remarkable Scientist, Instrumenter, and Person

    NASA Astrophysics Data System (ADS)

    Fritz, T. A.

    Berend Wilken has provided the space physics community with a series of innova- tive instruments that have measured charged particles as part of many international satellite projects. These spaceflight instruments are noteworthy for their progression toward the definitive set of measurements needed to address the outstanding problems facing each of the individual missions with which he was involved. Initially these instruments consisted of making a careful and detailed measurement of the particle energy spectrum of the major ion species and electrons. As hints about the role of ion composition in many of the scientific processes became topics of debate, Berend Wilken turned his attention to the development and perfection of time-of-flight tech- niques. In addition to the person himself I would like to discuss the impact of two such instrument efforts, the Polar CAMMICE MICS and the Cluster RAPID IIMS, have had in changing the concept of the dayside magnetospheric cusp from that of a narrow funnel-shaped region near local noon to an extremely broad region in both latitude and local time in which active acceleration processes are probably occurring.

  13. Health assessment instruments for people with intellectual disabilities-A systematic review.

    PubMed

    Bakker-van Gijssel, E J; Lucassen, P L B J; Olde Hartman, T C; van Son, L; Assendelft, W J J; van Schrojenstein Lantman-de Valk, H M J

    2017-05-01

    People with intellectual disabilities (ID) experience health disparities and are less likely to undergo recommended age- and gender-specific screening and health promotion. New diagnoses are frequently missed. Assessments with the aid of health assessment instruments are a way to address these problems. The aim of this review is to find the available health assessment instruments for people with ID used in primary care and evaluate their quality. We conducted an electronic literature search of papers published between January 2000 and May 2016. After a two-phase selection process (kappa: 0.81 and 0.77) we collected data from the 29 included peer-reviewed articles on the following four domains; development, clinimetric properties (i.e. validity, reliability, feasibility, acceptability), content (i.e. ID-related health problems, prevention and health promotion topics) and effectiveness of the instruments. We distinguished 20 different health assessment instruments. Limited information was found on the development of the instruments as well as on their clinimetric properties. The content of the instruments was rather diverse. The included papers agreed that health assessment instruments are effective. However, only three instruments evaluated effectiveness in a randomised controlled trial. Patients with ID, carers and general practitioners (GPs) generally appreciated the health assessment instruments. Two instruments, "Stay well and healthy -Health risk appraisal (SWH-HRA)"and the "Comprehensive Health Assessment Programme (CHAP)", appeared to have the highest quality. These instruments can be used to construct a health assessment instrument for people with ID that meets scientific standards. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. The silicon chip: A versatile micro-scale platform for micro- and nano-scale systems

    NASA Astrophysics Data System (ADS)

    Choi, Edward

    Cutting-edge advances in micro- and nano-scale technology require instrumentation to interface with the external world. While technology feature sizes are continually being reduced, the size of experimentalists and their instrumentation do not mirror this trend. Hence there is a need for effective application-specific instrumentation to bridge the gap from the micro and nano-scale phenomena being studied to the comparative macro-scale of the human interfaces. This dissertation puts forward the idea that the silicon CMOS integrated circuit, or microchip in short, serves as an excellent platform to perform this functionality. The electronic interfaces designed for the semiconductor industry are particularly attractive as development platforms, and the reduction in feature sizes that has been a hallmark of the industry suggests that chip-scale instrumentation may be more closely coupled to the phenomena of interest, allowing finer control or improved measurement capabilities. Compatibility with commercial processes will further enable economies of scale through mass production, another welcome feature of this approach. Thus chip-scale instrumentation may replace the bulky, expensive, cumbersome-to-operate macro-scale prototypes currently in use for many of these applications. The dissertation examines four specific applications in which the chip may serve as the ideal instrumentation platform. These are nanorod manipulation, polypyrrole bilayer hinge microactuator control, organic transistor hybrid circuits, and contact fluorescence imaging. The thesis is structured around chapters devoted to each of these projects, in addition to a chapter on preliminary work on an RFID system that serves as a wireless interface model. Each of these chapters contains tools and techniques developed for chip-scale instrumentation, from custom scripts for automated layout and data collection to microfabrication processes. Implementation of these tools to develop systems for the applications above is evaluated. The viability of this approach is not limited to the examples listed in this work, and innovative new methodologies beyond those included here may be developed in the future for other systems which would benefit from the versatility of chip-scale platforms.

  15. Design of an 8-40 GHz Antenna for the Wideband Instrument for Snow Measurements (WISM)

    NASA Technical Reports Server (NTRS)

    Durham, Timothy E.; Vanhille, Kenneth J.; Trent, Christopher; Lambert, Kevin M.; Miranda, Felix A.

    2015-01-01

    Measurement of land surface snow remains a significant challenge in the remote sensing arena. Developing the tools needed to remotely measure Snow Water Equivalent (SWE) is an important priority. The Wideband Instrument for Snow Measurements (WISM) is being developed to address this need. WISM is an airborne instrument comprised of a dual-frequency (X- and Ku-bands) Synthetic Aperture Radar (SAR) and dual-frequency (K- and Ka-bands) radiometer. A unique feature of this instrument is that all measurement bands share a common antenna aperture consisting of an array feed reflector that covers the entire bandwidth. This paper covers the design and fabrication of the wideband array feed which is based on tightly coupled dipole arrays. Implementation using a relatively new multi-layer microfabrication process results in a small, 6x6 element, dual-linear polarized array with beamformer that operates from 8 to 40 gigahertz.

  16. Addendum report to atmospheric science facility pallet-only mode space transportation system payload feasibility study, volume 3, revision A

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The feasibility of accomplishing selected atmospheric science mission using a pallet-only mode was studied. Certain unresolved issues were identified. The first issue was that of assuring that the on-board computer facility was adequate to process scientific data, control subsystems such as instrument pointing, provide mission operational program capability, and accomplish display and control. The second issue evolved from an investigation of the availability of existing substitute instruments that could be used instead of the prime instrumentation where the development tests and schedules are incompatible with the realistic budgets and shuttle vehicle schedules. Some effort was expended on identifying candidate substitute instruments, and the performance, cost, and development schedule trade-offs found during that effort were significant enough to warrant a follow-on investigation. This addendum documents the results of that follow-on effort, as it applies to the Atmospheric Sciences Facility.

  17. Dimension Reduction of Hyperspectral Data on Beowulf Clusters

    NASA Technical Reports Server (NTRS)

    El-Ghazawi, Tarek

    2000-01-01

    Traditional remote sensing instruments are multispectral, where observations are collected at a few different spectral bands. Recently, many hyperspectral instruments, that can collect observations at hundreds of bands, have been operation. Furthermore, there have been ongoing research efforts on ultraspectral instruments that can produce observations at thousands of spectral bands. While these remote sensing technology developments hold a great promise for new findings in the area of Earth and space science, they present many challenges. These include the need for faster processing of such increased data volumes, and methods for data reduction. Dimension Reduction is a spectral transformation, which is used widely in remote sensing, is the Principal Components Analysis (PCA). In light of the growing number of spectral channels of modern instruments, the paper reports on the development of a parallel PCA and its implementation on two Beowulf cluster configurations, on with fast Ethernet switch and the other is with a Myrinet interconnection.

  18. Development of esMOCA RULA, Motion Capture Instrumentation for RULA Assessment

    NASA Astrophysics Data System (ADS)

    Akhmad, S.; Arendra, A.

    2018-01-01

    The purpose of this research is to build motion capture instrumentation using sensors fusion accelerometer and gyroscope to assist in RULA assessment. Data processing of sensor orientation is done in every sensor node by digital motion processor. Nine sensors are placed in the upper limb of operator subject. Development of kinematics model is done with Simmechanic Simulink. This kinematics model receives streaming data from sensors via wireless sensors network. The output of the kinematics model is the relative angular angle between upper limb members and visualized on the monitor. This angular information is compared to the look-up table of the RULA worksheet and gives the RULA score. The assessment result of the instrument is compared with the result of the assessment by rula assessors. To sum up, there is no significant difference of assessment by the instrument with an assessment by an assessor.

  19. Design of Instrument Control Software for Solar Vector Magnetograph at Udaipur Solar Observatory

    NASA Astrophysics Data System (ADS)

    Gosain, Sanjay; Venkatakrishnan, P.; Venugopalan, K.

    2004-04-01

    A magnetograph is an instrument which makes measurement of solar magnetic field by measuring Zeeman induced polarization in solar spectral lines. In a typical filter based magnetograph there are three main modules namely, polarimeter, narrow-band spectrometer (filter), and imager(CCD camera). For a successful operation of magnetograph it is essential that these modules work in synchronization with each other. Here, we describe the design of instrument control system implemented for the Solar Vector Magnetograph under development at Udaipur Solar Observatory. The control software is written in Visual Basic and exploits the Component Object Model (COM) components for a fast and flexible application development. The user can interact with the instrument modules through a Graphical User Interface (GUI) and can program the sequence of magnetograph operations. The integration of Interactive Data Language (IDL) ActiveX components in the interface provides a powerful tool for online visualization, analysis and processing of images.

  20. The AAO fiber instrument data simulator

    NASA Astrophysics Data System (ADS)

    Goodwin, Michael; Farrell, Tony; Smedley, Scott; Heald, Ron; Heijmans, Jeroen; De Silva, Gayandhi; Carollo, Daniela

    2012-09-01

    The fiber instrument data simulator is an in-house software tool that simulates detector images of fiber-fed spectrographs developed by the Australian Astronomical Observatory (AAO). In addition to helping validate the instrument designs, the resulting simulated images are used to develop the required data reduction software. Example applications that have benefited from the tool usage are the HERMES and SAMI instrumental projects for the Anglo-Australian Telescope (AAT). Given the sophistication of these projects an end-to-end data simulator that accurately models the predicted detector images is required. The data simulator encompasses all aspects of the transmission and optical aberrations of the light path: from the science object, through the atmosphere, telescope, fibers, spectrograph and finally the camera detectors. The simulator runs under a Linux environment that uses pre-calculated information derived from ZEMAX models and processed data from MATLAB. In this paper, we discuss the aspects of the model, software, example simulations and verification.

  1. Optical radiation measurements and instrumentation.

    PubMed

    Andersen, F A; Landry, R J

    1981-07-01

    Accurate measurement of optical radiation is required when sources of optical radiation are used in biological research. Such measurement of broad-band noncoherent optical radiations usually must be performed by a highly trained specialist using sophisticated, complex, and expensive instruments. Presentation of the results of such measurement requires correct use of quantities and units with which many biological researchers are unfamiliar. The measurement process, quantities, units, measurement systems and instruments, and uncertainties associated with optical radiation measurements are reviewed in this paper. A conventional technique for evaluating the potential hazards associated with broad-band sources of optical radiation and a spectroradiometer developed to measure spectral quantities is described. A new prototype ultraviolet radiation hazard monitor which has recently been developed is also presented. This new instrument utilizes a spectrograph and a spectral weighting mechanical mask and provides a direct reading of the effective irradiance for wavelengths less than 315 nm.

  2. Wide area methane emissions mapping with airborne IPDA lidar

    NASA Astrophysics Data System (ADS)

    Bartholomew, Jarett; Lyman, Philip; Weimer, Carl; Tandy, William

    2017-08-01

    Methane emissions from natural gas production, storage, and transportation are potential sources of greenhouse gas emissions. Methane leaks also constitute revenue loss potential from operations. Since 2013, Ball Aerospace has been developing advanced airborne sensors using integrated path differential absorption (IPDA) LIDAR instrumentation to identify methane, propane, and longer-chain alkanes in the lowest region of the atmosphere. Additional funding has come from the U.S. Department of Transportation, Pipeline and Hazardous Materials Administration (PHMSA) to upgrade instrumentation to a broader swath coverage of up to 400 meters while maintaining high spatial sampling resolution and geolocation accuracy. Wide area coverage allows efficient mapping of emissions from gathering and distribution networks, processing facilities, landfills, natural seeps, and other distributed methane sources. This paper summarizes the benefits of advanced instrumentation for aerial methane emission mapping, describes the operating characteristics and design of this upgraded IPDA instrumentation, and reviews technical challenges encountered during development and deployment.

  3. A Platform to Build Mobile Health Apps: The Personal Health Intervention Toolkit (PHIT).

    PubMed

    Eckhoff, Randall Peter; Kizakevich, Paul Nicholas; Bakalov, Vesselina; Zhang, Yuying; Bryant, Stephanie Patrice; Hobbs, Maria Ann

    2015-06-01

    Personal Health Intervention Toolkit (PHIT) is an advanced cross-platform software framework targeted at personal self-help research on mobile devices. Following the subjective and objective measurement, assessment, and plan methodology for health assessment and intervention recommendations, the PHIT platform lets researchers quickly build mobile health research Android and iOS apps. They can (1) create complex data-collection instruments using a simple extensible markup language (XML) schema; (2) use Bluetooth wireless sensors; (3) create targeted self-help interventions based on collected data via XML-coded logic; (4) facilitate cross-study reuse from the library of existing instruments and interventions such as stress, anxiety, sleep quality, and substance abuse; and (5) monitor longitudinal intervention studies via daily upload to a Web-based dashboard portal. For physiological data, Bluetooth sensors collect real-time data with on-device processing. For example, using the BinarHeartSensor, the PHIT platform processes the heart rate data into heart rate variability measures, and plots these data as time-series waveforms. Subjective data instruments are user data-entry screens, comprising a series of forms with validation and processing logic. The PHIT instrument library consists of over 70 reusable instruments for various domains including cognitive, environmental, psychiatric, psychosocial, and substance abuse. Many are standardized instruments, such as the Alcohol Use Disorder Identification Test, Patient Health Questionnaire-8, and Post-Traumatic Stress Disorder Checklist. Autonomous instruments such as battery and global positioning system location support continuous background data collection. All data are acquired using a schedule appropriate to the app's deployment. The PHIT intelligent virtual advisor (iVA) is an expert system logic layer, which analyzes the data in real time on the device. This data analysis results in a tailored app of interventions and other data-collection instruments. For example, if a user anxiety score exceeds a threshold, the iVA might add a meditation intervention to the task list in order to teach the user how to relax, and schedule a reassessment using the anxiety instrument 2 weeks later to re-evaluate. If the anxiety score exceeds a higher threshold, then an advisory to seek professional help would be displayed. Using the easy-to-use PHIT scripting language, the researcher can program new instruments, the iVA, and interventions to their domain-specific needs. The iVA, instruments, and interventions are defined via XML files, which facilities rapid app development and deployment. The PHIT Web-based dashboard portal provides the researcher access to all the uploaded data. After a secure login, the data can be filtered by criteria such as study, protocol, domain, and user. Data can also be exported into a comma-delimited file for further processing. The PHIT framework has proven to be an extensible, reconfigurable technology that facilitates mobile data collection and health intervention research. Additional plans include instrument development in other domains, additional health sensors, and a text messaging notification system.

  4. A Platform to Build Mobile Health Apps: The Personal Health Intervention Toolkit (PHIT)

    PubMed Central

    2015-01-01

    Personal Health Intervention Toolkit (PHIT) is an advanced cross-platform software framework targeted at personal self-help research on mobile devices. Following the subjective and objective measurement, assessment, and plan methodology for health assessment and intervention recommendations, the PHIT platform lets researchers quickly build mobile health research Android and iOS apps. They can (1) create complex data-collection instruments using a simple extensible markup language (XML) schema; (2) use Bluetooth wireless sensors; (3) create targeted self-help interventions based on collected data via XML-coded logic; (4) facilitate cross-study reuse from the library of existing instruments and interventions such as stress, anxiety, sleep quality, and substance abuse; and (5) monitor longitudinal intervention studies via daily upload to a Web-based dashboard portal. For physiological data, Bluetooth sensors collect real-time data with on-device processing. For example, using the BinarHeartSensor, the PHIT platform processes the heart rate data into heart rate variability measures, and plots these data as time-series waveforms. Subjective data instruments are user data-entry screens, comprising a series of forms with validation and processing logic. The PHIT instrument library consists of over 70 reusable instruments for various domains including cognitive, environmental, psychiatric, psychosocial, and substance abuse. Many are standardized instruments, such as the Alcohol Use Disorder Identification Test, Patient Health Questionnaire-8, and Post-Traumatic Stress Disorder Checklist. Autonomous instruments such as battery and global positioning system location support continuous background data collection. All data are acquired using a schedule appropriate to the app’s deployment. The PHIT intelligent virtual advisor (iVA) is an expert system logic layer, which analyzes the data in real time on the device. This data analysis results in a tailored app of interventions and other data-collection instruments. For example, if a user anxiety score exceeds a threshold, the iVA might add a meditation intervention to the task list in order to teach the user how to relax, and schedule a reassessment using the anxiety instrument 2 weeks later to re-evaluate. If the anxiety score exceeds a higher threshold, then an advisory to seek professional help would be displayed. Using the easy-to-use PHIT scripting language, the researcher can program new instruments, the iVA, and interventions to their domain-specific needs. The iVA, instruments, and interventions are defined via XML files, which facilities rapid app development and deployment. The PHIT Web-based dashboard portal provides the researcher access to all the uploaded data. After a secure login, the data can be filtered by criteria such as study, protocol, domain, and user. Data can also be exported into a comma-delimited file for further processing. The PHIT framework has proven to be an extensible, reconfigurable technology that facilitates mobile data collection and health intervention research. Additional plans include instrument development in other domains, additional health sensors, and a text messaging notification system. PMID:26033047

  5. Ground-Based Calibration Of A Microwave Landing System

    NASA Technical Reports Server (NTRS)

    Kiriazes, John J.; Scott, Marshall M., Jr.; Willis, Alfred D.; Erdogan, Temel; Reyes, Rolando

    1996-01-01

    System of microwave instrumentation and data-processing equipment developed to enable ground-based calibration of microwave scanning-beam landing system (MSBLS) at distances of about 500 to 1,000 ft from MSBLS transmitting antenna. Ensures accuracy of MSBLS near touchdown point, without having to resort to expense and complex logistics of aircraft-based testing. Modified versions prove useful in calibrating aircraft instrument landing systems.

  6. The management of external marketing communication instruments in health care services.

    PubMed

    Bobocea, L; Spiridon, St; Petrescu, L; Gheorghe, C M; Purcarea, V L

    2016-01-01

    In order to become known and attract consumers, a health care organization has to develop suitable external communication campaigns. Consequently, management instruments are employed to effectively evaluate the success of a campaign. The BCG Matrix, SWOT analysis and the Gantt Diagram were used in this paper to ensure the consistency and accuracy of the external communication process at an empirical level.

  7. The management of external marketing communication instruments in health care services

    PubMed Central

    Bobocea, L; Spiridon, St; Petrescu, L; Gheorghe, CM; Purcarea, VL

    2016-01-01

    In order to become known and attract consumers, a health care organization has to develop suitable external communication campaigns. Consequently, management instruments are employed to effectively evaluate the success of a campaign. The BCG Matrix, SWOT analysis and the Gantt Diagram were used in this paper to ensure the consistency and accuracy of the external communication process at an empirical level. PMID:27453742

  8. Popular Participation in Development: Emerging Trends in Community Development.

    ERIC Educational Resources Information Center

    United Nations, New York, NY. Dept. of Economic and Social Affairs.

    A first attempt is made to place in perspective the accumulated experience of nearly 20 years of community development activity in both developed and developing countries. The purpose of this study is to stimulate further inquiry into community development practice, process, and theory in order for it to become a more effective instrument in the…

  9. Women's perceptions of social support during labour: development, reliability and validity of the Birth Companion Support Questionnaire.

    PubMed

    Dunne, Carmel L; Fraser, Jennifer; Gardner, Glenn E

    2014-07-01

    to develop and test the reliability and validity of a research instrument to measure women's perceptions of social support provided during labour by at least one lay birth companion. a cross-sectional study was carried out from April 2009 to February 2010. non-tertiary hospital in the outer western region of Brisbane, Australia. six registered midwives and 10 postnatal women reviewed the instrument. The instrument was then completed by 293 inpatient women who had experienced a vaginal birth. the Birth Companion Support Questionnaire (BCSQ) was developed and its reliability and validity were evaluated in this study. An exploratory factor analysis was performed on the final instrument using principal component analysis with an oblique (Promax) rotation. This process suggested two subscales: emotional support and tangible support. The questionnaire was found to be reliable and valid for use in midwifery research. the BCSQ is an appropriate instrument to measure women's perceptions of lay birth companion support during labour. this is the first rigorous study to develop and test a measure of social support in labour which is critical at a time when policy makers and health planners need to consider the needs of birthing women and their network of support friends and family. © 2013 Elsevier Ltd. All rights reserved.

  10. Development and Validation of an Instrument to Measure Students' Motivation and Self-Regulation in Science Learning

    NASA Astrophysics Data System (ADS)

    Velayutham, Sunitadevi; Aldridge, Jill; Fraser, Barry

    2011-10-01

    Students' motivational beliefs and self-regulatory practices have been identified as instrumental in influencing the engagement of students in the learning process. An important aim of science education is to empower students by nurturing the belief that they can succeed in science learning and to cultivate the adaptive learning strategies required to help to bring about that success. This article reports the development and validation of an instrument to measure salient factors related to the motivation and self-regulation of students in lower secondary science classrooms. The development of the instrument involved identifying key determinants of students' motivation and self-regulation in science learning based on theoretical and research underpinnings. Once the instrument was developed, a pilot study involving 52 students from two Grade 8 science classes was undertaken. Quantitative data were collected from 1,360 students in 78 classes across Grades 8, 9, and 10, in addition to in-depth qualitative information gathered from 10 experienced science teachers and 12 Grade 8 students. Analyses of the data suggest that the survey has strong construct validity when used with lower secondary students. This survey could be practically valuable as a tool for gathering information that may guide classroom teachers in refocusing their teaching practices and help to evaluate the effectiveness of intervention programmes.

  11. Analysis of In Situ Thermal Ion Measurements from the MICA Sounding Rocket

    NASA Astrophysics Data System (ADS)

    Fernandes, P. A.; Lynch, K. A.; Zettergren, M. D.; Hampton, D. L.; Fisher, L. E.; Powell, S. P.

    2014-12-01

    The MICA sounding rocket launched on 19 Feb. 2012 into several discrete, localized arcs in the wake of a westward traveling surge. In situ and ground-based observations provide a measured response of the ionosphere to preflight and localized auroral drivers. Initial analysis of the in situ thermal ion data indicate possible measurement of an ion conic at low altitude (< 325 km). In the low-energy regime, the response of the instrument varies from the ideal because the measured thermal ion population is sensitive to the presence of the instrument. The plasma is accelerated in the frame of the instrument due to flows, ram, and acceleration through the sheath which forms around the spacecraft. The energies associated with these processes are large compared to the thermal energy. Correct interpretation of thermal plasma measurements requires accounting for all of these plasma processes and the non-ideal response of the instrument in the low-energy regime. This is an experimental and modeling project which involves thorough analysis of ionospheric thermal ion data from the MICA campaign. Analysis includes modeling and measuring the instrument response in the low-energy regime as well as accounting for the complex sheath formed around the instrument. This results in a forward model in which plasma parameters of the thermal plasma are propagated through the sheath and instrument models, resulting in an output which matches the in situ measurement. In the case of MICA, we are working toward answering the question of the initiating source processes that result, at higher altitudes, in well-developed conics and outflow on auroral field lines.

  12. Modeling surface topography of state-of-the-art x-ray mirrors as a result of stochastic polishing process: recent developments

    NASA Astrophysics Data System (ADS)

    Yashchuk, Valeriy V.; Centers, Gary; Tyurin, Yuri N.; Tyurina, Anastasia

    2016-09-01

    Recently, an original method for the statistical modeling of surface topography of state-of-the-art mirrors for usage in xray optical systems at light source facilities and for astronomical telescopes [Opt. Eng. 51(4), 046501, 2012; ibid. 53(8), 084102 (2014); and ibid. 55(7), 074106 (2016)] has been developed. In modeling, the mirror surface topography is considered to be a result of a stationary uniform stochastic polishing process and the best fit time-invariant linear filter (TILF) that optimally parameterizes, with limited number of parameters, the polishing process is determined. The TILF model allows the surface slope profile of an optic with a newly desired specification to be reliably forecast before fabrication. With the forecast data, representative numerical evaluations of expected performance of the prospective mirrors in optical systems under development become possible [Opt. Eng., 54(2), 025108 (2015)]. Here, we suggest and demonstrate an analytical approach for accounting the imperfections of the used metrology instruments, which are described by the instrumental point spread function, in the TILF modeling. The efficacy of the approach is demonstrated with numerical simulations for correction of measurements performed with an autocollimator based surface slope profiler. Besides solving this major metrological problem, the results of the present work open an avenue for developing analytical and computational tools for stitching data in the statistical domain, obtained using multiple metrology instruments measuring significantly different bandwidths of spatial wavelengths.

  13. White-light Interferometry using a Channeled Spectrum: II. Calibration Methods, Numerical and Experimental Results

    NASA Technical Reports Server (NTRS)

    Zhai, Chengxing; Milman, Mark H.; Regehr, Martin W.; Best, Paul K.

    2007-01-01

    In the companion paper, [Appl. Opt. 46, 5853 (2007)] a highly accurate white light interference model was developed from just a few key parameters characterized in terms of various moments of the source and instrument transmission function. We develop and implement the end-to-end process of calibrating these moment parameters together with the differential dispersion of the instrument and applying them to the algorithms developed in the companion paper. The calibration procedure developed herein is based on first obtaining the standard monochromatic parameters at the pixel level: wavenumber, phase, intensity, and visibility parameters via a nonlinear least-squares procedure that exploits the structure of the model. The pixel level parameters are then combined to obtain the required 'global' moment and dispersion parameters. The process is applied to both simulated scenarios of astrometric observations and to data from the microarcsecond metrology testbed (MAM), an interferometer testbed that has played a prominent role in the development of this technology.

  14. The OPTICON technology roadmap for optical and infrared astronomy

    NASA Astrophysics Data System (ADS)

    Cunningham, Colin; Melotte, David; Molster, Frank

    2010-07-01

    The Key Technology Network (KTN) within the OPTICON programme has been developing a roadmap for the technology needed to meet the challenges of optical and infrared astronomy over the next few years, with particular emphasis on the requirements of Extremely Large Telescopes. The process and methodology so far will be described, along with the most recent roadmap. The roadmap shows the expected progression of ground-based astronomy facilities and the technological developments which will be required to realise these new facilities. The roadmap highlights the key stages in the development of these technologies. In some areas, such as conventional optics, gradual developments in areas such as light-weighting of optics will slowly be adopted into future instruments. In other areas, such as large area IR detectors, more rapid progress can be expected as new processing techniques allow larger and faster arrays. Finally, other areas such as integrated photonics have the potential to revolutionise astronomical instrumentation. Future plans are outlined, in particular our intention to look at longer term development and disruptive technologies.

  15. Structural Safety of a Hubble Space Telescope Science Instrument

    NASA Technical Reports Server (NTRS)

    Lou, M. C.; Brent, D. N.

    1993-01-01

    This paper gives an overview of safety requirements related to structural design and verificationof payloads to be launched and/or retrieved by the Space Shuttle. To demonstrate the generalapproach used to implement these requirements in the development of a typical Shuttle payload, theWide Field/Planetary Camera II, a second generation science instrument currently being developed bythe Jet Propulsion Laboratory (JPL) for the Hubble Space Telescope is used as an example. Inaddition to verification of strength and dynamic characteristics, special emphasis is placed upon thefracture control implementation process, including parts classification and fracture controlacceptability.

  16. ACRF Instrumentation Status: New, Current, and Future - January 2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    AS Koontz; S Choudhury; BD Ermold

    2008-01-31

    The purpose of this report is to provide status of the ingest software used to process instrument data for the Atmospheric Radiation Measurement Program Climate Research Facility (ACRF). The report is divided into 4 sections: (1) for news about ingests currently under development, (2) for current production ingests, (3) for future ingest development plans, and (4) for information on retired ingests. Please note that datastreams beginning in “xxx” indicate cases where ingests run at multiple ACRF sites, which results in a datastream(s) for each location.

  17. Science Data Preservation: Implementation and Why It Is Important

    NASA Technical Reports Server (NTRS)

    Kempler, Steven J.; Moses, John F.; Gerasimov, Irina V.; Johnson, James E.; Vollmer, Bruce E.; Theobald, Michael L.; Ostrenga, Dana M.; Ahmad, Suraiya; Ramapriyan, Hampapuram K.; Khayat, Mohammad G.

    2013-01-01

    Remote Sensing data generation by NASA to study Earth s geophysical processes was initiated in 1960 with the launch of the first Television Infrared Observation Satellite Program (TIROS), to develop a meteorological satellite information system. What would be deemed as a primitive data set by today s standards, early Earth science missions were the foundation upon which today s remote sensing instruments have built their scientific success, and tomorrow s instruments will yield science not yet imagined. NASA Scientific Data Stewardship requirements have been documented to ensure the long term preservation and usability of remote sensing science data. In recent years, the Federation of Earth Science Information Partners and NASA s Earth Science Data System Working Groups have organized committees that specifically examine standards, processes, and ontologies that can best be employed for the preservation of remote sensing data, supporting documentation, and data provenance information. This presentation describes the activities, issues, and implementations, guided by the NASA Earth Science Data Preservation Content Specification (423-SPEC-001), for preserving instrument characteristics, and data processing and science information generated for 20 Earth science instruments, spanning 40 years of geophysical measurements, at the NASA s Goddard Earth Sciences Data and Information Services Center (GES DISC). In addition, unanticipated preservation/implementation questions and issues in the implementation process are presented.

  18. On the development of a magnetoresistive sensor for blade tip timing and blade tip clearance measurement systems.

    PubMed

    Tomassini, R; Rossi, G; Brouckaert, J-F

    2016-10-01

    A simultaneous blade tip timing (BTT) and blade tip clearance (BTC) measurement system enables the determination of turbomachinery blade vibrations and ensures the monitoring of the existing running gaps between the blade tip and the casing. This contactless instrumentation presents several advantages compared to the well-known telemetry system with strain gauges, at the cost of a more complex data processing procedure. The probes used can be optical, capacitive, eddy current as well as microwaves, everyone with its dedicated electronics and many existing different signal processing algorithms. Every company working in this field has developed its own processing method and sensor technology. Hence, repeating the same test with different instrumentations, the answer is often different. Moreover, rarely it is possible to achieve reliability for in-service measurements. Developments are focused on innovative instrumentations and a common standard. This paper focuses on the results achieved using a novel magnetoresistive sensor for simultaneous tip timing and tip clearance measurements. The sensor measurement principle is described. The sensitivity to gap variation is investigated. In terms of measurement of vibrations, experimental investigations were performed at the Air Force Institute of Technology (ITWL, Warsaw, Poland) in a real aeroengine and in the von Karman Institute (VKI) R2 compressor rig. The advantages and limitations of the magnetoresistive probe for turbomachinery testing are highlighted.

  19. On the development of a magnetoresistive sensor for blade tip timing and blade tip clearance measurement systems

    NASA Astrophysics Data System (ADS)

    Tomassini, R.; Rossi, G.; Brouckaert, J.-F.

    2016-10-01

    A simultaneous blade tip timing (BTT) and blade tip clearance (BTC) measurement system enables the determination of turbomachinery blade vibrations and ensures the monitoring of the existing running gaps between the blade tip and the casing. This contactless instrumentation presents several advantages compared to the well-known telemetry system with strain gauges, at the cost of a more complex data processing procedure. The probes used can be optical, capacitive, eddy current as well as microwaves, everyone with its dedicated electronics and many existing different signal processing algorithms. Every company working in this field has developed its own processing method and sensor technology. Hence, repeating the same test with different instrumentations, the answer is often different. Moreover, rarely it is possible to achieve reliability for in-service measurements. Developments are focused on innovative instrumentations and a common standard. This paper focuses on the results achieved using a novel magnetoresistive sensor for simultaneous tip timing and tip clearance measurements. The sensor measurement principle is described. The sensitivity to gap variation is investigated. In terms of measurement of vibrations, experimental investigations were performed at the Air Force Institute of Technology (ITWL, Warsaw, Poland) in a real aeroengine and in the von Karman Institute (VKI) R2 compressor rig. The advantages and limitations of the magnetoresistive probe for turbomachinery testing are highlighted.

  20. Product development: the making of the Abbott ARCHITECT.

    PubMed

    Kisner, H J

    1997-01-01

    Many laboratorians have a limited perspective on what is involved in developing an instrument and bringing it to market. This article traces the product development process used by Abbott Diagnostics Division that resulted in Abbott being named the 1996 Concurrent Engineering Company of the Year for the design of the ARCHITECT.

  1. Modeling Cometary Coma with a Three Dimensional, Anisotropic Multiple Scattering Distributed Processing Code

    NASA Technical Reports Server (NTRS)

    Luchini, Chris B.

    1997-01-01

    Development of camera and instrument simulations for space exploration requires the development of scientifically accurate models of the objects to be studied. Several planned cometary missions have prompted the development of a three dimensional, multi-spectral, anisotropic multiple scattering model of cometary coma.

  2. The Metacognitive Awareness Listening Questionnaire: Development and Validation

    ERIC Educational Resources Information Center

    Vandergrift, Larry; Goh, Christine C. M.; Mareschal, Catherine J.; Tafaghodtari, Marzieh H.

    2006-01-01

    This article describes the development and validation of a listening questionnaire designed to assess second language (L2) listeners' metacognitive awareness and perceived use of strategies while listening to oral texts. The process of instrument development and validation is described, along with a review of the relevant literature related to…

  3. Development and Validation of the Physics Anxiety Rating Scale

    ERIC Educational Resources Information Center

    Sahin, Mehmet; Caliskan, Serap; Dilek, Ufuk

    2015-01-01

    This study reports the development and validation process for an instrument to measure university students' anxiety in physics courses. The development of the Physics Anxiety Rating Scale (PARS) included the following steps: Generation of scale items, content validation, construct validation, and reliability calculation. The results of construct…

  4. The Thirty Gigahertz Instrument Receiver for the QUIJOTE Experiment: Preliminary Polarization Measurements and Systematic-Error Analysis.

    PubMed

    Casas, Francisco J; Ortiz, David; Villa, Enrique; Cano, Juan L; Cagigas, Jaime; Pérez, Ana R; Aja, Beatriz; Terán, J Vicente; de la Fuente, Luisa; Artal, Eduardo; Hoyland, Roger; Génova-Santos, Ricardo

    2015-08-05

    This paper presents preliminary polarization measurements and systematic-error characterization of the Thirty Gigahertz Instrument receiver developed for the QUIJOTE experiment. The instrument has been designed to measure the polarization of Cosmic Microwave Background radiation from the sky, obtaining the Q, U, and I Stokes parameters of the incoming signal simultaneously. Two kinds of linearly polarized input signals have been used as excitations in the polarimeter measurement tests in the laboratory; these show consistent results in terms of the Stokes parameters obtained. A measurement-based systematic-error characterization technique has been used in order to determine the possible sources of instrumental errors and to assist in the polarimeter calibration process.

  5. 2017 Marine Hydrokinetic Instrumentation Workshop Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Driscoll, Frederick R; Mauer, Erik; Rieks, Jeff

    The third Marine Hydrokinetic Instrumentation Workshop was held at Florida Atlantic University's Sea Tech Campus in Dania Beach, Florida, from February 28 to March 1, 2017. The workshop brought together 37 experts in marine energy measurement, testing, and technology development to present and discuss the instrumentation and data-processing needs of the marine energy industry. The workshop was comprised of a plenary session followed by two focused breakout sessions. The half-day plenary session reviewed findings from prior instrumentation workshops, presented research activities that aim to fill previously identified gaps, and had industry experts present the state of the marine energy measurementmore » technologies. This report provides further detail on the workshop, objectives, and findings.« less

  6. Small Cold Temperature Instrument Packages

    NASA Astrophysics Data System (ADS)

    Clark, P. E.; Millar, P. S.; Yeh, P. S.; Feng, S.; Brigham, D.; Beaman, B.

    We are developing a small cold temperature instrument package concept that integrates a cold temperature power system with ultra low temperature ultra low power electronics components and power supplies now under development into a 'cold temperature surface operational' version of a planetary surface instrument package. We are already in the process of developing a lower power lower temperature version for an instrument of mutual interest to SMD and ESMD to support the search for volatiles (the mass spectrometer VAPoR, Volatile Analysis by Pyrolysis of Regolith) both as a stand alone instrument and as part of an environmental monitoring package. We build on our previous work to develop strategies for incorporating Ultra Low Temperature/Ultra Low Power (ULT/ULP) electronics, lower voltage power supplies, as well as innovative thermal design concepts for instrument packages. Cryotesting has indicated that our small Si RHBD CMOS chips can deliver >80% of room temperature performance at 40K (nominal minimum lunar surface temperature). We leverage collaborations, past and current, with the JPL battery development program to increase power system efficiency in extreme environments. We harness advances in MOSFET technology that provide lower voltage thresholds for power switching circuits incorporated into our low voltage power supply concept. Conventional power conversion has a lower efficiency. Our low power circuit concept based on 'synchronous rectification' could produce stable voltages as low as 0.6 V with 85% efficiency. Our distributed micro-battery-based power supply concept incorporates cold temperature power supplies operating with a 4 V or 8 V battery. This work will allow us to provide guidelines for applying the low temperature, low power system approaches generically to the widest range of surface instruments.

  7. VISSR Atmospheric Sounder (VAS) Research Review

    NASA Technical Reports Server (NTRS)

    Greaves, J. R. (Editor)

    1983-01-01

    The VAS, an experimental instrument flown onboard Geostationary Operational Environmental Satellite (GOES), is capable of achieving mutlispectral imagery of atmospheric temperature, water vapor, and cloudiness patterns over short time intervals. In addition, this instrument provides an atmospheric sounding capability from geosynchronous orbit. The VAS demonstration is an effort for evaluating the VAS instrument's performance, and for demonstrating the capabilities of a VAS prototype system to provide useful geosynchronous satellite data for supporting weather forecasts and atmospheric research. The demonstration evaluates the performance of the VAS Instruments on GOES-4-5, and -6, develops research oriented and prototype/operational VAS data processing systems, determines the accuracy of certain basic and derived meteorological parameters that can be obtained from the VAS instrument, and assesses the utility of VAS derived information in analyzing severe weather situations.

  8. Development of self and peer performance assessment on iodometric titration experiment

    NASA Astrophysics Data System (ADS)

    Nahadi; Siswaningsih, W.; Kusumaningtyas, H.

    2018-05-01

    This study aims to describe the process in developing of reliable and valid assessment to measure students’ performance on iodometric titration and the effect of the self and peer assessment on students’ performance. The self and peer-instrument provides valuable feedback for the student performance improvement. The developed assessment contains rubric and task for facilitating self and peer assessment. The participants are 24 students at the second-grade student in certain vocational high school in Bandung. The participants divided into two groups. The first 12 students involved in the validity test of the developed assessment, while the remain 12 students participated for the reliability test. The content validity was evaluated based on the judgment experts. Test result of content validity based on judgment expert show that the developed performance assessment instrument categorized as valid on each task with the realibity classified as very good. Analysis of the impact of the self and peer assessment implementation showed that the peer instrument supported the self assessment.

  9. Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments.

    PubMed

    Shen, Ya; Zhou, Hui-min; Zheng, Yu-feng; Peng, Bin; Haapasalo, Markus

    2013-02-01

    The performance and mechanical properties of nickel-titanium (NiTi) instruments are influenced by factors such as cross-section, flute design, raw material, and manufacturing processes. Many improvements have been proposed by manufacturers during the past decade to provide clinicians with safer and more efficient instruments. The mechanical performance of NiTi alloys is sensitive to their microstructure and associated thermomechanical treatment history. Heat treatment or thermal processing is one of the most fundamental approaches toward adjusting the transition temperature in NiTi alloy, which affects the fatigue resistance of NiTi endodontic files. The newly developed NiTi instruments made from controlled memory wire, M-Wire (Dentsply Tulsa Dental Specialties, Tulsa, OK), or R-phase wire represent the next generation of NiTi alloys with improved flexibility and fatigue resistance. The advantages of NiTi files for canal cleaning and shaping are decreased canal transportation and ledging, a reduced risk of file fracture, and faster and more efficient instrumentation. The clinician must understand the nature of different NiTi raw materials and their impact on instrument performance because many new instruments are introduced on a regular basis. This review summarizes the metallurgical properties of next-generation NiTi instruments, the impact of thermomechanical treatment on instrument flexibility, and the resistance to cyclic fatigue and torsion. The aim of this review was to provide clinicians with the knowledge necessary for evidence-based practices, maximizing the benefits from the selection and application of NiTi rotary instruments for root canal treatment. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  10. Assessing the overuse of antibiotics in children in Saudi Arabia: validation of the parental perception on antibiotics scale (PAPA scale)

    PubMed Central

    2013-01-01

    Background Antibiotics overuse is a global public health issue influenced by several factors, of which some are parent-related psychosocial factors that can only be measured using valid and reliable psychosocial measurement instruments. The PAPA scale was developed to measure these factors and the content validity of this instrument was assessed. Aim This study further validated the recently developed instrument in terms of (1) face validity and (2) construct validity including: deciding the number and nature of factors, and item selection. Methods Questionnaires were self-administered to parents of children between the ages of 0 and 12 years old. Parents were conveniently recruited from schools’ parental meetings in the Eastern Province, Saudi Arabia. Face validity was assessed with regards to questionnaire clarity and unambiguity. Construct validity and item selection processes were conducted using Exploratory factor analysis. Results Parallel analysis and Exploratory factor analysis using principal axis factoring produced six factors in the developed instrument: knowledge and beliefs, behaviours, sources of information, adherence, awareness about antibiotics resistance, and parents’ perception regarding doctors’ prescribing behaviours. Reliability was assessed (Cronbach’s alpha = 0.78) which demonstrates the instrument as being reliable. Conclusion The ‘factors’ produced in this study coincide with the constructs contextually identified in the development phase of other instruments used to study antibiotic use. However, no other study considering perceptions of antibiotic use had gone beyond content validation of such instruments. This study is the first to constructively validate the factors underlying perceptions regarding antibiotic use in any population and in parents in particular. PMID:23497151

  11. Development and preliminary evidence for the validity of an instrument assessing implementation of human-factors principles in medication-related decision-support systems—I-MeDeSA

    PubMed Central

    Zachariah, Marianne; Seidling, Hanna M; Neri, Pamela M; Cresswell, Kathrin M; Duke, Jon; Bloomrosen, Meryl; Volk, Lynn A; Bates, David W

    2011-01-01

    Background Medication-related decision support can reduce the frequency of preventable adverse drug events. However, the design of current medication alerts often results in alert fatigue and high over-ride rates, thus reducing any potential benefits. Methods The authors previously reviewed human-factors principles for relevance to medication-related decision support alerts. In this study, instrument items were developed for assessing the appropriate implementation of these human-factors principles in drug–drug interaction (DDI) alerts. User feedback regarding nine electronic medical records was considered during the development process. Content validity, construct validity through correlation analysis, and inter-rater reliability were assessed. Results The final version of the instrument included 26 items associated with nine human-factors principles. Content validation on three systems resulted in the addition of one principle (Corrective Actions) to the instrument and the elimination of eight items. Additionally, the wording of eight items was altered. Correlation analysis suggests a direct relationship between system age and performance of DDI alerts (p=0.0016). Inter-rater reliability indicated substantial agreement between raters (κ=0.764). Conclusion The authors developed and gathered preliminary evidence for the validity of an instrument that measures the appropriate use of human-factors principles in the design and display of DDI alerts. Designers of DDI alerts may use the instrument to improve usability and increase user acceptance of medication alerts, and organizations selecting an electronic medical record may find the instrument helpful in meeting their clinicians' usability needs. PMID:21946241

  12. ARO Research Instrumentation Program - IR Spectrometer Procurement

    DTIC Science & Technology

    2015-11-01

    supercapacitors ). The Nicolet iS50R spectrometer has been synchronized with a potentiostat to 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE...interfaces. This information is important for the development of enhanced energy conversion processes and devices (e.g., supercapacitors ). The Nicolet iS50R...electrode interfaces. This information is important for the development of enhanced energy conversion processes and devices (e.g., supercapacitors

  13. "Smart pebble" designs for sediment transport monitoring

    NASA Astrophysics Data System (ADS)

    Valyrakis, Manousos; Alexakis, Athanasios; Pavlovskis, Edgars

    2015-04-01

    Sediment transport, due to primarily the action of water, wind and ice, is one of the most significant geomorphic processes responsible for shaping Earth's surface. It involves entrainment of sediment grains in rivers and estuaries due to the violently fluctuating hydrodynamic forces near the bed. Here an instrumented particle, namely a "smart pebble", is developed to investigate the exact flow conditions under which individual grains may be entrained from the surface of a gravel bed. This could lead in developing a better understanding of the processes involved, focusing on the response of the particle during a variety of flow entrainment events. The "smart pebble" is a particle instrumented with MEMS sensors appropriate for capturing the hydrodynamic forces a coarse particle might experience during its entrainment from the river bed. A 3-axial gyroscope and accelerometer registers data to a memory card via a microcontroller, embedded in a 3D-printed waterproof hollow spherical particle. The instrumented board is appropriately fit and centred into the shell of the pebble, so as to achieve a nearly uniform distribution of the mass which could otherwise bias its motion. The "smart pebble" is powered by an independent power to ensure autonomy and sufficiently long periods of operation appropriate for deployment in the field. Post-processing and analysis of the acquired data is currently performed offline, using scientific programming software. The performance of the instrumented particle is validated, conducting a series of calibration experiments under well-controlled laboratory conditions.

  14. Potential commercial uses of EOS remote sensing products

    NASA Technical Reports Server (NTRS)

    Thompson, Leslie L.

    1991-01-01

    The instrument complement of the Earth Observing System (EOS) satellite system will generate data sets with potential interest to a variety of users who are now just beginning to develop geographic information systems tailored to their special applications and/or jurisdictions. Other users may be looking for a unique product that enhances competitive position. The generally distributed products from EOS will require additional value added processing to derive the unique products desired by specific users. Entrepreneurs have an opportunity to create these proprietary level 4 products from the EOS data sets. Specific instruments or collections of instruments could provide information for crop futures trading, mineral exploration, television and printed medium news products, regional and local government land management and planning, digital map directories, products for third world users, ocean fishing fleet probability of harvest forecasts, and other areas not even imagined at this time. The projected level 3 product are examined that will be available at launch from EOS instruments and commercial uses of the data after value added processing is estimated.

  15. Calibration of an electronic nose for poultry farm

    NASA Astrophysics Data System (ADS)

    Abdullah, A. H.; Shukor, S. A.; Kamis, M. S.; Shakaff, A. Y. M.; Zakaria, A.; Rahim, N. A.; Mamduh, S. M.; Kamarudin, K.; Saad, F. S. A.; Masnan, M. J.; Mustafa, H.

    2017-03-01

    Malodour from the poultry farms could cause air pollution and therefore potentially dangerous to humans' and animals' health. This issue also poses sustainability risk to the poultry industries due to objections from local community. The aim of this paper is to develop and calibrate a cost effective and efficient electronic nose for poultry farm air monitoring. The instrument main components include sensor chamber, array of specific sensors, microcontroller, signal conditioning circuits and wireless sensor networks. The instrument was calibrated to allow classification of different concentrations of main volatile compounds in the poultry farm malodour. The outcome of the process will also confirm the device's reliability prior to being used for poultry farm malodour assessment. The Multivariate Analysis (HCA and KNN) and Artificial Neural Network (ANN) pattern recognition technique was used to process the acquired data. The results show that the instrument is able to calibrate the samples using ANN classification model with high accuracy. The finding verifies the instrument's performance to be used as an effective poultry farm malodour monitoring.

  16. Development and validation of the Bush-Francis Catatonia Rating Scale - Brazilian version.

    PubMed

    Nunes, Ana Letícia Santos; Filgueiras, Alberto; Nicolato, Rodrigo; Alvarenga, Jussara Mendonça; Silveira, Luciana Angélica Silva; Silva, Rafael Assis da; Cheniaux, Elie

    2017-01-01

    This article aims to describe the adaptation and translation process of the Bush-Francis Catatonia Rating Scale (BFCRS) and its reduced version, the Bush-Francis Catatonia Screening Instrument (BFCSI) for Brazilian Portuguese, as well as its validation. Semantic equivalence processes included four steps: translation, back translation, evaluation of semantic equivalence and a pilot-study. Validation consisted of simultaneous applications of the instrument in Portuguese by two examiners in 30 catatonic and 30 non-catatonic patients. Total scores averaged 20.07 for the complete scale and 7.80 for its reduced version among catatonic patients, compared with 0.47 and 0.20 among non-catatonic patients, respectively. Overall values of inter-rater reliability of the instruments were 0.97 for the BFCSI and 0.96 for the BFCRS. The scale's version in Portuguese proved to be valid and was able to distinguish between catatonic and non-catatonic patients. It was also reliable, with inter-evaluator reliability indexes as high as those of the original instrument.

  17. Multi-Mission Laser Altimeter Data Processing and Co-Registration of Image and Laser Data at DLR

    NASA Astrophysics Data System (ADS)

    Stark, A.; Matz, K.-D.; Roatsch, T.

    2018-04-01

    We designed a system for the processing and storage of large laser altimeter data sets for various past and operating laser altimeter instruments. Furthermore, we developed a technique to accurately co-register multi-mission laser and image data.

  18. The Influence of Thought Suppression and Cognitive Load on Intrusions and Memory Processes following an Analogue Stressor

    ERIC Educational Resources Information Center

    Nixon, Reginald D. V.; Cain, Neralie; Nehmy, Thomas; Seymour, Melanie

    2009-01-01

    Ironic Process Theory and the role of thought suppression have been used in part to explain the phenomenon of intrusive memories in various disorders, including posttraumatic stress disorder. How thought suppression interacts with other cognitive processes believed to be instrumental in the development of traumatic intrusive memory is unclear. In…

  19. Flame resistant elastomeric polymer development. [for use in space shuttle instrument packaging

    NASA Technical Reports Server (NTRS)

    Howarth, J. T.; Sheth, S. G.; Sidman, K. R.

    1975-01-01

    Elastomeric products were developed for use in the space shuttle program, and investigations were conducted to improve the properties of elastomers developed in previous programs, and to evaluate the possibility of using lower-cost general purpose polymers. Products were fabricated and processed on conventional processing equipment; these products include: foams based on fluorinated rubber flame-retarded compounds with a density of 20-30 pounds/cubic foot for use as padding and in helmets; foams based on urethane for use in instrument packaging in the space shuttle; flexible and semi-rigid films of fluorinated rubber and neoprene compounds that would not burn in a 70% nitrogen, 30% oxygen atmosphere, and in a 30% nitrogen, 70% oxygen atmosphere, respectively for use in packaging or in laminates; coated fabrics which used both nylon and Kelvar fabric substrates, coated with either fluorinated or neoprene polymer compositions to meet specific levels of flame retardancy; and other flame-resistant materials.

  20. The effect of the use of android-based application in learning together to improve students' academic performance

    NASA Astrophysics Data System (ADS)

    Ulfa, Andi Maria; Sugiyarto, Kristian H.; Ikhsan, Jaslin

    2017-05-01

    Poor achievement of students' performance on Chemistry may result from unfavourable learning processes. Therefore, innovation on learning process must be created. Regarding fast development of mobile technology, learning process cannot ignore the crucial role of the technology. This research and development (R&D) studies was done to develop android based application and to study the effect of its integration in Learning together (LT) into the improvement of students' learning creativity and cognitive achievement. The development of the application was carried out by adapting Borg & Gall and Dick & Carey model. The developed-product was reviewed by chemist, learning media practitioners, peer reviewers, and educators. After the revision based on the reviews, the application was used in the LT model on the topic of Stoichiometry in a senior high school. The instruments were questionnaires to get comments and suggestion from the reviewers about the application, and the another questionnaire was to collect the data of learning creativity. Another instrument used was a set of test by which data of students' achievement was collected. The results showed that the use of the mobile based application on Learning Together can bring about significant improvement of students' performance including creativity and cognitive achievement.

  1. Digital Beamforming Synthetic Aperture Radar Developments at NASA Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Rincon, Rafael; Fatoyinbo, Temilola; Osmanoglu, Batuhan; Lee, Seung Kuk; Du Toit, Cornelis F.; Perrine, Martin; Ranson, K. Jon; Sun, Guoqing; Deshpande, Manohar; Beck, Jaclyn; hide

    2016-01-01

    Advanced Digital Beamforming (DBF) Synthetic Aperture Radar (SAR) technology is an area of research and development pursued at the NASA Goddard Space Flight Center (GSFC). Advanced SAR architectures enhances radar performance and opens a new set of capabilities in radar remote sensing. DBSAR-2 and EcoSAR are two state-of-the-art radar systems recently developed and tested. These new instruments employ multiple input-multiple output (MIMO) architectures characterized by multi-mode operation, software defined waveform generation, digital beamforming, and configurable radar parameters. The instruments have been developed to support several disciplines in Earth and Planetary sciences. This paper describes the radars advanced features and report on the latest SAR processing and calibration efforts.

  2. Development of Pediatric Sleep Questionnaires as Diagnostic or Epidemiological Tools: A Brief Review of Do's and Don'ts

    PubMed Central

    Spruyt, Karen; Gozal, David

    2010-01-01

    Questionnaires are a useful and extensively used tool in clinical sleep medicine and in sleep research. The number of sleep questionnaires targeting the pediatric age range has tremendously increased in recent years, and with such explosion in the number of instruments, their heterogeneity has become all the more apparent. Here, we explore the theoretical and pragmatic processes required for instrument design and development, i.e., how any questionnaire, inventory, log, or diary should be created and evaluated, and also provide illustrative examples to further underline the potential pitfalls that are inherently embedded in every step of tool development. PMID:20952230

  3. Operational Monitoring of GOME-2 and IASI Level 1 Product Processing at EUMETSAT

    NASA Astrophysics Data System (ADS)

    Livschitz, Yakov; Munro, Rosemary; Lang, Rüdiger; Fiedler, Lars; Dyer, Richard; Eisinger, Michael

    2010-05-01

    The growing complexity of operational level 1 radiance products from Low Earth Orbiting (LEO) platforms like EUMETSATs Metop series makes near-real-time monitoring of product quality a challenging task. The main challenge is to provide a monitoring system which is flexible and robust enough to identify and to react to anomalies which may be previously unknown to the system, as well as to provide all means and parameters necessary in order to support efficient ad-hoc analysis of the incident. The operational monitoring system developed at EUMETSAT for monitoring of GOME-2 and IASI level 1 data allows to perform near-real-time monitoring of operational products and instrument's health in a robust and flexible fashion. For effective information management, the system is based on a relational database (Oracle). An Extract, Transform, Load (ETL) process transforms products in EUMETSAT Polar System (EPS) format into relational data structures. The identification of commonalities between products and instruments allows for a database structure design in such a way that different data can be analyzed using the same business intelligence functionality. An interactive analysis software implementing modern data mining techniques is also provided for a detailed look into the data. The system is effectively used for day-to-day monitoring, long-term reporting, instrument's degradation analysis as well as for ad-hoc queries in case of an unexpected instrument or processing behaviour. Having data from different sources on a single instrument and even from different instruments, platforms or numerical weather prediction within the same database allows effective cross-comparison and looking for correlated parameters. Automatic alarms raised by checking for deviation of certain parameters, for data losses and other events significantly reduce time, necessary to monitor the processing on a day-to-day basis.

  4. Conceptual designs of NDA instruments for the NRTA system at the Rokkasho Reprocessing Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, T.K.; Klosterbuer, S.F.; Menlove, H.O.

    The authors are studying conceptual designs of selected nondestructive assay (NDA) instruments for the near-real-time accounting system at the rokkasho Reprocessing Plant (RRP) of Japan Nuclear Fuel Limited (JNFL). The JNFL RRP is a large-scale commercial reprocessing facility for spent fuel from boiling-water and pressurized-water reactors. The facility comprises two major components: the main process area to separate and produce purified plutonium nitrate and uranyl nitrate from irradiated reactor spent fuels, and the co-denitration process area to combine and convert the plutonium nitrate and uranyl nitrate into mixed oxide (MOX). The selected NDA instruments for conceptual design studies are themore » MOX-product canister counter, holdup measurement systems for calcination and reduction furnaces and for blenders in the co-denitration process, the isotope dilution gamma-ray spectrometer for the spent fuel dissolver solution, and unattended verification systems. For more effective and practical safeguards and material control and accounting at RRP, the authors are also studying the conceptual design for the UO{sub 3} large-barrel counter. This paper discusses the state-of-the-art NDA conceptual design and research and development activities for the above instruments.« less

  5. Flexible Workflow Software enables the Management of an Increased Volume and Heterogeneity of Sensors, and evolves with the Expansion of Complex Ocean Observatory Infrastructures.

    NASA Astrophysics Data System (ADS)

    Tomlin, M. C.; Jenkyns, R.

    2015-12-01

    Ocean Networks Canada (ONC) collects data from observatories in the northeast Pacific, Salish Sea, Arctic Ocean, Atlantic Ocean, and land-based sites in British Columbia. Data are streamed, collected autonomously, or transmitted via satellite from a variety of instruments. The Software Engineering group at ONC develops and maintains Oceans 2.0, an in-house software system that acquires and archives data from sensors, and makes data available to scientists, the public, government and non-government agencies. The Oceans 2.0 workflow tool was developed by ONC to manage a large volume of tasks and processes required for instrument installation, recovery and maintenance activities. Since 2013, the workflow tool has supported 70 expeditions and grown to include 30 different workflow processes for the increasing complexity of infrastructures at ONC. The workflow tool strives to keep pace with an increasing heterogeneity of sensors, connections and environments by supporting versioning of existing workflows, and allowing the creation of new processes and tasks. Despite challenges in training and gaining mutual support from multidisciplinary teams, the workflow tool has become invaluable in project management in an innovative setting. It provides a collective place to contribute to ONC's diverse projects and expeditions and encourages more repeatable processes, while promoting interactions between the multidisciplinary teams who manage various aspects of instrument development and the data they produce. The workflow tool inspires documentation of terminologies and procedures, and effectively links to other tools at ONC such as JIRA, Alfresco and Wiki. Motivated by growing sensor schemes, modes of collecting data, archiving, and data distribution at ONC, the workflow tool ensures that infrastructure is managed completely from instrument purchase to data distribution. It integrates all areas of expertise and helps fulfill ONC's mandate to offer quality data to users.

  6. Skylab

    NASA Image and Video Library

    1971-04-01

    This photograph shows Skylab's Extreme Ultraviolet (XUV) Spectroheliograph during an acceptance test and checkout procedures in April 1971. The unit was an Apollo Telescope Mount (ATM) instrument designed to sequentially photograph the solar chromosphere and corona in selected ultraviolet wavelengths. The instrument also obtained information about composition, temperature, energy conversion and transfer, and plasma processes of the chromosphere and lower corona. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.

  7. The Geostationary Operational Satellite R Series SpaceWire Based Data System

    NASA Technical Reports Server (NTRS)

    Anderson, William; Birmingham, Michael; Krimchansky, Alexander; Lombardi, Matthew

    2016-01-01

    The Geostationary Operational Environmental Satellite R-Series Program (GOES-R, S, T, and U) mission is a joint program between National Oceanic & Atmospheric Administration (NOAA) and National Aeronautics & Space Administration (NASA) Goddard Space Flight Center (GSFC). SpaceWire was selected as the science data bus as well as command and telemetry for the GOES instruments. GOES-R, S, T, and U spacecraft have a mission data loss requirement for all data transfers between the instruments and spacecraft requiring error detection and correction at the packet level. The GOES-R Reliable Data Delivery Protocol (GRDDP) [1] was developed in house to provide a means of reliably delivering data among various on board sources and sinks. The GRDDP was presented to and accepted by the European Cooperation for Space Standardization (ECSS) and is part of the ECSS Protocol Identification Standard [2]. GOES-R development and integration is complete and the observatory is scheduled for launch November 2016. Now that instrument to spacecraft integration is complete, GOES-R Project reviewed lessons learned to determine how the GRDDP could be revised to improve the integration process. Based on knowledge gained during the instrument to spacecraft integration process the following is presented to help potential GRDDP users improve their system designs and implementation.

  8. Selecting relevant and feasible measurement instruments for the revised Dutch clinical practice guideline for physical therapy in patients after stroke.

    PubMed

    Otterman, Nicoline; Veerbeek, Janne; Schiemanck, Sven; van der Wees, Philip; Nollet, Frans; Kwakkel, Gert

    2017-07-01

    To select relevant and feasible instruments for the revision of the Dutch clinical practice guideline for physical therapy in patients with stroke. In this implementation study a comprehensive proposal for ICF categories and matching instruments was developed, based on reliability and validity. Relevant instruments were then selected in a consensus round by 11 knowledge brokers who were responsible for the implementation of the selected instruments. The feasibility of the selected instruments was tested by 36 physical therapists at different work settings within stroke services. Finally, instruments that were deemed relevant and feasible were included in the revised guideline. A total of 28 instruments were recommended for inclusion in the revised guideline. Nineteen instruments were retained from the previous guideline. Ten new instruments were tested in clinical practice, seven of which were found feasible. Two more instruments were added after critical appraisal of the set of the measurement instruments. The revised guideline contains 28 relevant and feasible instrument selected and tested in clinical practice by physical therapists. Further education and implementation is needed to integrate instruments in clinical practice. Further research is proposed for developing and implementing a core set of measurement instruments to be used at fixed time points to establish data registries that allow for continuous improvement of rehabilitation for stroke patients. Implications for Rehabilitation The revised Dutch Stroke Physical Therapy Guideline recommends a total of 28 instruments, that are relevant and feasible for clinical practice of physical therapist in the different settings of stroke rehabilitation. The selection of instrument in daily practice should be part of the clinical reasoning process of PTs and be tailored to individual patients' needs and the degree of priority of the affected ICF category. Suggested education strategies for further integration of instruments in of the daily practice of PTs in Stroke Rehabilitation are: 'Training on the job' and 'peer assessment in clinical situations'.

  9. Patient-Reported Outcome (PRO) Consortium translation process: consensus development of updated best practices.

    PubMed

    Eremenco, Sonya; Pease, Sheryl; Mann, Sarah; Berry, Pamela

    2017-01-01

    This paper describes the rationale and goals of the Patient-Reported Outcome (PRO) Consortium's instrument translation process. The PRO Consortium has developed a number of novel PRO measures which are in the process of qualification by the U.S. Food and Drug Administration (FDA) for use in clinical trials where endpoints based on these measures would support product labeling claims. Given the importance of FDA qualification of these measures, the PRO Consortium's Process Subcommittee determined that a detailed linguistic validation (LV) process was necessary to ensure that all translations of Consortium-developed PRO measures are performed using a standardized approach with the rigor required to meet regulatory and pharmaceutical industry expectations, as well as having a clearly defined instrument translation process that the translation industry can support. The consensus process involved gathering information about current best practices from 13 translation companies with expertise in LV, consolidating the findings to generate a proposed process, and obtaining iterative feedback from the translation companies and PRO Consortium member firms on the proposed process in two rounds of review in order to update existing principles of good practice in LV and to provide sufficient detail for the translation process to ensure consistency across PRO Consortium measures, sponsors, and translation companies. The consensus development resulted in a 12-step process that outlines universal and country-specific new translation approaches, as well as country-specific adaptations of existing translations. The PRO Consortium translation process will play an important role in maintaining the validity of the data generated through these measures by ensuring that they are translated by qualified linguists following a standardized and rigorous process that reflects best practice.

  10. The TOPSAR interferometric radar topographic mapping instrument

    NASA Technical Reports Server (NTRS)

    Zebker, Howard A.; Madsen, Soren N.; Martin, Jan; Alberti, Giovanni; Vetrella, Sergio; Cucci, Alessandro

    1992-01-01

    The NASA DC-8 AIRSAR instrument was augmented with a pair of C-band antennas displaced across track to form an interferometer sensitive to topographic variations of the Earth's surface. The antennas were developed by the Italian consortium Co.Ri.S.T.A., under contract to the Italian Space Agency (ASI), while the AIRSAR instrument and modifications to it supporting TOPSAR were sponsored by NASA. A new data processor was developed at JPL for producing the topographic maps, and a second processor was developed at Co.Ri.S.T.A. All the results presented below were processed at JPL. During the 1991 DC-8 flight campaign, data were acquired over several sites in the United States and Europe, and topographic maps were produced from several of these flight lines. Analysis of the results indicate that statistical errors are in the 2-3 m range for flat terrain and in the 4-5 m range for mountainous areas.

  11. NASA Instrument Cost/Schedule Model

    NASA Technical Reports Server (NTRS)

    Habib-Agahi, Hamid; Mrozinski, Joe; Fox, George

    2011-01-01

    NASA's Office of Independent Program and Cost Evaluation (IPCE) has established a number of initiatives to improve its cost and schedule estimating capabilities. 12One of these initiatives has resulted in the JPL developed NASA Instrument Cost Model. NICM is a cost and schedule estimator that contains: A system level cost estimation tool; a subsystem level cost estimation tool; a database of cost and technical parameters of over 140 previously flown remote sensing and in-situ instruments; a schedule estimator; a set of rules to estimate cost and schedule by life cycle phases (B/C/D); and a novel tool for developing joint probability distributions for cost and schedule risk (Joint Confidence Level (JCL)). This paper describes the development and use of NICM, including the data normalization processes, data mining methods (cluster analysis, principal components analysis, regression analysis and bootstrap cross validation), the estimating equations themselves and a demonstration of the NICM tool suite.

  12. [Urban shrinkage and challenges for the public health-care service].

    PubMed

    Kabisch, S

    2007-10-01

    In the 21st century, urban development is facing new challenges caused by the simultaneous growing and shrinking of cities and urban regions. Whilst the development patterns and instruments of urban growth are well-known and widely accepted, the processes of shrinkage with its broad consequences, sphere of impact and speed need intensive investigation. In particular, urban restructuring including housing demolition brings about psychological stress situations for the affected inhabitants. Until the present time public services, including health-care, are poorly prepared to cope with the new situation. To take account of these new challenges, the adaptation of tasks, instruments and targets is urgently needed. To be successful, a continuous cooperation and communication between municipal institutions and housing enterprises responsible for urban and housing development is indispensable. Furthermore, appropriately focussed scientific research results can support the creation of adequate strategies and instruments.

  13. Multi-Mission Automated Task Invocation Subsystem

    NASA Technical Reports Server (NTRS)

    Cheng, Cecilia S.; Patel, Rajesh R.; Sayfi, Elias M.; Lee, Hyun H.

    2009-01-01

    Multi-Mission Automated Task Invocation Subsystem (MATIS) is software that establishes a distributed data-processing framework for automated generation of instrument data products from a spacecraft mission. Each mission may set up a set of MATIS servers for processing its data products. MATIS embodies lessons learned in experience with prior instrument- data-product-generation software. MATIS is an event-driven workflow manager that interprets project-specific, user-defined rules for managing processes. It executes programs in response to specific events under specific conditions according to the rules. Because requirements of different missions are too diverse to be satisfied by one program, MATIS accommodates plug-in programs. MATIS is flexible in that users can control such processing parameters as how many pipelines to run and on which computing machines to run them. MATIS has a fail-safe capability. At each step, MATIS captures and retains pertinent information needed to complete the step and start the next step. In the event of a restart, this information is retrieved so that processing can be resumed appropriately. At this writing, it is planned to develop a graphical user interface (GUI) for monitoring and controlling a product generation engine in MATIS. The GUI would enable users to schedule multiple processes and manage the data products produced in the processes. Although MATIS was initially designed for instrument data product generation,

  14. Advanced optical instruments technology

    NASA Technical Reports Server (NTRS)

    Shao, Mike; Chrisp, Michael; Cheng, Li-Jen; Eng, Sverre; Glavich, Thomas; Goad, Larry; Jones, Bill; Kaarat, Philip; Nein, Max; Robinson, William

    1992-01-01

    The science objectives for proposed NASA missions for the next decades push the state of the art in sensitivity and spatial resolution over a wide range of wavelengths, including the x-ray to the submillimeter. While some of the proposed missions are larger and more sensitive versions of familiar concepts, such as the next generation space telescope, others use concepts, common on the Earth, but new to space, such as optical interferometry, in order to provide spatial resolutions impossible with other concepts. However, despite their architecture, the performance of all of the proposed missions depends critically on the back-end instruments that process the collected energy to produce scientifically interesting outputs. The Advanced Optical Instruments Technology panel was chartered with defining technology development plans that would best improve optical instrument performance for future astrophysics missions. At this workshop the optical instrument was defined as the set of optical components that reimage the light from the telescope onto the detectors to provide information about the spatial, spectral, and polarization properties of the light. This definition was used to distinguish the optical instrument technology issues from those associated with the telescope, which were covered by a separate panel. The panel identified several areas for optical component technology development: diffraction gratings; tunable filters; interferometric beam combiners; optical materials; and fiber optics. The panel also determined that stray light suppression instruments, such as coronagraphs and nulling interferometers, were in need of general development to support future astrophysics needs.

  15. Disease-specific health-related quality of life instruments for IgE-mediated food allergy.

    PubMed

    Salvilla, S A; Dubois, A E J; Flokstra-de Blok, B M J; Panesar, S S; Worth, A; Patel, S; Muraro, A; Halken, S; Hoffmann-Sommergruber, K; DunnGalvin, A; Hourihane, J O'B; Regent, L; de Jong, N W; Roberts, G; Sheikh, A

    2014-07-01

    This is one of seven interlinked systematic reviews undertaken on behalf of the European Academy of Allergy and Clinical Immunology as part of their Guidelines for Food Allergy and Anaphylaxis, which focuses on instruments developed for IgE-mediated food allergy. Disease-specific questionnaires are significantly more sensitive than generic ones in measuring the response to interventions or future treatments, as well as estimating the general burden of food allergy. The aim of this systematic review was therefore to identify which disease-specific, validated instruments can be employed to enable assessment of the impact of, and investigations and interventions for, IgE-mediated food allergy on health-related quality of life (HRQL). Using a sensitive search strategy, we searched seven electronic bibliographic databases to identify disease-specific quality of life (QOL) tools relating to IgE-mediated food allergy. From the 17 eligible studies, we identified seven disease-specific HRQL instruments, which were then subjected to detailed quality appraisal. This revealed that these instruments have undergone formal development and validation processes, and have robust psychometric properties, and therefore provide a robust means of establishing the impact of food allergy on QOL. Suitable instruments are now available for use in children, adolescents, parents/caregivers, and adults. Further work must continue to develop a clinical minimal important difference for food allergy and for making these instruments available in a wider range of European languages. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Advanced optical instruments technology

    NASA Astrophysics Data System (ADS)

    Shao, Mike; Chrisp, Michael; Cheng, Li-Jen; Eng, Sverre; Glavich, Thomas; Goad, Larry; Jones, Bill; Kaarat, Philip; Nein, Max; Robinson, William

    1992-08-01

    The science objectives for proposed NASA missions for the next decades push the state of the art in sensitivity and spatial resolution over a wide range of wavelengths, including the x-ray to the submillimeter. While some of the proposed missions are larger and more sensitive versions of familiar concepts, such as the next generation space telescope, others use concepts, common on the Earth, but new to space, such as optical interferometry, in order to provide spatial resolutions impossible with other concepts. However, despite their architecture, the performance of all of the proposed missions depends critically on the back-end instruments that process the collected energy to produce scientifically interesting outputs. The Advanced Optical Instruments Technology panel was chartered with defining technology development plans that would best improve optical instrument performance for future astrophysics missions. At this workshop the optical instrument was defined as the set of optical components that reimage the light from the telescope onto the detectors to provide information about the spatial, spectral, and polarization properties of the light. This definition was used to distinguish the optical instrument technology issues from those associated with the telescope, which were covered by a separate panel. The panel identified several areas for optical component technology development: diffraction gratings; tunable filters; interferometric beam combiners; optical materials; and fiber optics. The panel also determined that stray light suppression instruments, such as coronagraphs and nulling interferometers, were in need of general development to support future astrophysics needs.

  17. Work environments for employee creativity.

    PubMed

    Dul, Jan; Ceylan, Canan

    2011-01-01

    Innovative organisations need creative employees who generate new ideas for product or process innovation. This paper presents a conceptual framework for the effect of personal, social-organisational and physical factors on employee creativity. Based on this framework, an instrument to analyse the extent to which the work environment enhances creativity is developed. This instrument was applied to a sample of 409 employees and support was found for the hypothesis that a creative work environment enhances creative performance. This paper illustrates how the instrument can be used in companies to select and implement improvements. STATEMENT OF RELEVANCE: The ergonomics discipline addresses the work environment mainly for improving health and safety and sometimes productivity and quality. This paper opens a new area for ergonomics: designing work environments for enhancing employee creativity in order to strengthen an organisation's capability for product and process innovation and, consequently, its competitiveness.

  18. A VIIRS ocean data simulator

    NASA Astrophysics Data System (ADS)

    Robinson, Wayne D.; Patt, Frederick S.; Franz, Bryan A.; Turpie, Kevin R.; McClain, Charles R.

    2009-08-01

    One of the roles of the VIIRS Ocean Science Team (VOST) is to assess the performance of the instrument and scientific processing software that generates ocean color parameters such as normalized water-leaving radiances and chlorophyll. A VIIRS data simulator is being developed to help aid in this work. The simulator will create a sufficient set of simulated Sensor Data Records (SDR) so that the ocean component of the VIIRS processing system can be tested. It will also have the ability to study the impact of instrument artifacts on the derived parameter quality. The simulator will use existing resources available to generate the geolocation information and to transform calibrated radiances to geophysical parameters and visa-versa. In addition, the simulator will be able to introduce land features, cloud fields, and expected VIIRS instrument artifacts. The design of the simulator and its progress will be presented.

  19. [Adapting and validating the generic instrument CollaboRATE™ to measure women's participation in health related decision-making during the reproductive process].

    PubMed

    Bravo, Paulina; Contreras, Aixa; Dois, Angelina; Villarroel, Luis

    2018-05-01

    There is a worldwide interest in involving patients in health related decisions, so patients can actively search for therapeutic options and choose course of action that allows them to have better quality of life and wellbeing. The majority of the instruments available to capture the degree of participation in medical decision-making are in English and have been developed in high income countries. To adapt and validate for the Chilean context the instrument CollaboRATE™, to measure women's participation in medical decisions during the reproductive process. Cross-sectional study to adapt and validate the instrument CollaboRATE™. Maternity units in Santiago, Chile. Puerperal women in maternity units of three public hospitals. Translation and back-translation, cultural and linguistic relevance with service users and final revision by experts. Study for validation with 90 puerperal women. The Chilean version of CollaboRATE™ demonstrated to be a reliable instrument to capture the degree of patients' participation in medical decision-making. Cronbach alpha was above 0.89. This study provides the first instrument to capture the prevalence of SDM in a Latin American country. This instrument will be critical in future research efforts that seek to explore to what extent people are being involved in the decisions related to their healthcare. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  20. Technology Readiness Level Assessment Process as Applied to NASA Earth Science Missions

    NASA Technical Reports Server (NTRS)

    Leete, Stephen J.; Romero, Raul A.; Dempsey, James A.; Carey, John P.; Cline, Helmut P.; Lively, Carey F.

    2015-01-01

    Technology assessments of fourteen science instruments were conducted within NASA using the NASA Technology Readiness Level (TRL) Metric. The instruments were part of three NASA Earth Science Decadal Survey missions in pre-formulation. The Earth Systematic Missions Program (ESMP) Systems Engineering Working Group (SEWG), composed of members of three NASA Centers, provided a newly modified electronic workbook to be completed, with instructions. Each instrument development team performed an internal assessment of its technology status, prepared an overview of its instrument, and completed the workbook with the results of its assessment. A team from the ESMP SEWG met with each instrument team and provided feedback. The instrument teams then reported through the Program Scientist for their respective missions to NASA's Earth Science Division (ESD) on technology readiness, taking the SEWG input into account. The instruments were found to have a range of TRL from 4 to 7. Lessons Learned are presented; however, due to the competition-sensitive nature of the assessments, the results for specific missions are not presented. The assessments were generally successful, and produced useful results for the agency. The SEWG team identified a number of potential improvements to the process. Particular focus was on ensuring traceability to guiding NASA documents, including the NASA Systems Engineering Handbook. The TRL Workbook has been substantially modified, and the revised workbook is described.

  1. Instrument control software requirement specification for Extremely Large Telescopes

    NASA Astrophysics Data System (ADS)

    Young, Peter J.; Kiekebusch, Mario J.; Chiozzi, Gianluca

    2010-07-01

    Engineers in several observatories are now designing the next generation of optical telescopes, the Extremely Large Telescopes (ELT). These are very complex machines that will host sophisticated astronomical instruments to be used for a wide range of scientific studies. In order to carry out scientific observations, a software infrastructure is required to orchestrate the control of the multiple subsystems and functions. This paper will focus on describing the considerations, strategies and main issues related to the definition and analysis of the software requirements for the ELT's Instrument Control System using modern development processes and modelling tools like SysML.

  2. Derivation of Design Loads and Random Vibration specifications for Spacecraft Instruments and Sub-Units

    NASA Astrophysics Data System (ADS)

    Fransen, S.; Yamawaki, T.; Akagi, H.; Eggens, M.; van Baren, C.

    2014-06-01

    After a first estimation based on statistics, the design loads for instruments are generally estimated by coupled spacecraft/instrument sine analysis once an FE-model of the spacecraft is available. When the design loads for the instrument have been derived, the next step in the process is to estimate the random vibration environment at the instrument base and to compute the RMS load at the centre of gravity of the instrument by means of vibro-acoustic analysis. Finally the design loads of the light-weight sub-units of the instrument can be estimated through random vibration analysis at instrument level, taking into account the notches required to protect the instrument interfaces in the hard- mounted random vibration test. This paper presents the aforementioned steps of instrument and sub-units loads derivation in the preliminary design phase of the spacecraft and identifies the problems that may be encountered in terms of design load consistency between low-frequency and high-frequency environments. The SpicA FAR-infrared Instrument (SAFARI) which is currently developed for the Space Infrared Telescope for Cosmology and Astrophysics (SPICA) will be used as a guiding example.

  3. Data processing pipeline for Herschel HIFI

    NASA Astrophysics Data System (ADS)

    Shipman, R. F.; Beaulieu, S. F.; Teyssier, D.; Morris, P.; Rengel, M.; McCoey, C.; Edwards, K.; Kester, D.; Lorenzani, A.; Coeur-Joly, O.; Melchior, M.; Xie, J.; Sanchez, E.; Zaal, P.; Avruch, I.; Borys, C.; Braine, J.; Comito, C.; Delforge, B.; Herpin, F.; Hoac, A.; Kwon, W.; Lord, S. D.; Marston, A.; Mueller, M.; Olberg, M.; Ossenkopf, V.; Puga, E.; Akyilmaz-Yabaci, M.

    2017-12-01

    Context. The HIFI instrument on the Herschel Space Observatory performed over 9100 astronomical observations, almost 900 of which were calibration observations in the course of the nearly four-year Herschel mission. The data from each observation had to be converted from raw telemetry into calibrated products and were included in the Herschel Science Archive. Aims: The HIFI pipeline was designed to provide robust conversion from raw telemetry into calibrated data throughout all phases of the HIFI missions. Pre-launch laboratory testing was supported as were routine mission operations. Methods: A modular software design allowed components to be easily added, removed, amended and/or extended as the understanding of the HIFI data developed during and after mission operations. Results: The HIFI pipeline processed data from all HIFI observing modes within the Herschel automated processing environment as well as within an interactive environment. The same software can be used by the general astronomical community to reprocess any standard HIFI observation. The pipeline also recorded the consistency of processing results and provided automated quality reports. Many pipeline modules were in use since the HIFI pre-launch instrument level testing. Conclusions: Processing in steps facilitated data analysis to discover and address instrument artefacts and uncertainties. The availability of the same pipeline components from pre-launch throughout the mission made for well-understood, tested, and stable processing. A smooth transition from one phase to the next significantly enhanced processing reliability and robustness. Herschel was an ESA space observatory with science instruments provided by European-led Principal Investigator consortia and with important participation from NASA.

  4. The Relationship of Teacher Evaluation Scores Generated by a Process-Product Evaluation Instrument to Selected Variables.

    ERIC Educational Resources Information Center

    Tadlock, James; Nesbit, Lamar

    The Jackson Municipal Separate School District, Mississippi, has instituted a mixed-criteria reduction-in-force procedure emphasizing classroom performance to a greater degree than seniority, certification, and staff development participation. The district evaluation process--measuring classroom teaching performance--generated data for the present…

  5. Learning Styles and Self-Regulation.

    ERIC Educational Resources Information Center

    Vermunt, Jan D. H. M.

    Data from 211 adult students (ages 20 to 75) at the Open University, The Netherlands, were used to construct and test an instrument to measure learning styles and regulation processes. Test development was guided by a three-tiered model of self-regulation encompassing: (1) cognitive learning processes (deep, surface, elaborative); (2) regulation…

  6. Real-Time On-Board Airborne Demonstration of High-Speed On-Board Data Processing for Science Instruments (HOPS)

    NASA Technical Reports Server (NTRS)

    Beyon, Jeffrey Y.; Ng, Tak-Kwong; Davis, Mitchell J.; Adams, James K.; Bowen, Stephen C.; Fay, James J.; Hutchinson, Mark A.

    2015-01-01

    The project called High-Speed On-Board Data Processing for Science Instruments (HOPS) has been funded by NASA Earth Science Technology Office (ESTO) Advanced Information Systems Technology (AIST) program since April, 2012. The HOPS team recently completed two flight campaigns during the summer of 2014 on two different aircrafts with two different science instruments. The first flight campaign was in July, 2014 based at NASA Langley Research Center (LaRC) in Hampton, VA on the NASA's HU-25 aircraft. The science instrument that flew with HOPS was Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) CarbonHawk Experiment Simulator (ACES) funded by NASA's Instrument Incubator Program (IIP). The second campaign was in August, 2014 based at NASA Armstrong Flight Research Center (AFRC) in Palmdale, CA on the NASA's DC-8 aircraft. HOPS flew with the Multifunctional Fiber Laser Lidar (MFLL) instrument developed by Excelis Inc. The goal of the campaigns was to perform an end-to-end demonstration of the capabilities of the HOPS prototype system (HOPS COTS) while running the most computationally intensive part of the ASCENDS algorithm real-time on-board. The comparison of the two flight campaigns and the results of the functionality tests of the HOPS COTS are presented in this paper.

  7. The eXtra Small Analyzer for Neutrals (XSAN) instrument on-board of the Lunar-Glob lander

    NASA Astrophysics Data System (ADS)

    Wieser, Martin; Barabash, Stas

    A large fraction of up to 20 precent of the solar wind impinging onto the lunar surface is reflected back to space as energetic neutral atoms. The SARA instrument on the Chandrayaan-1 mission provided a comprehensive coverage of the lunar surface of this interaction by mapping it from a 100 - 200 km orbit. The micro-physics of this reflection process is unexplored however. With the eXtra Small Analyzer for Neutrals instrument (XSAN) placed on the Lunar-Glob lander, we will directly investigate the production process of energetic neutral atoms from a vantage point of only meters from the surface for the first time. The XSAN design is based on the Solar Wind Monitor (SWIM) family of instruments originally flown on the Indian Chandrayaan-1 mission and with derivatives built e.g. for ESA's BepiColombo Mission to Mercury or for Phobos-Grunt. XSAN extends the functionality of this instrument family by adding a neutral atom to ion conversion surface in its entrance system. This will make it possible to measure detailed energy spectra and mass composition of the energetic neutral atoms originating from the lunar surface. We present an overview of the XSAN instrument and its science and report on latest developments.

  8. The individual therapy process questionnaire: development and validation of a revised measure to evaluate general change mechanisms in psychotherapy.

    PubMed

    Mander, Johannes

    2015-01-01

    There is a dearth of measures specifically designed to assess empirically validated mechanisms of therapeutic change. To fill in this research gap, the aim of the current study was to develop a measure that covers a large variety of empirically validated mechanisms of change with corresponding versions for the patient and therapist. To develop an instrument that is based on several important change process frameworks, we combined two established change mechanisms instruments: the Scale for the Multiperspective Assessment of General Change Mechanisms in Psychotherapy (SACiP) and the Scale of the Therapeutic Alliance-Revised (STA-R). In our study, 457 psychosomatic inpatients completed the SACiP and the STA-R and diverse outcome measures in early, middle and late stages of psychotherapy. Data analyses were conducted using factor analyses and multilevel modelling. The psychometric properties of the resulting Individual Therapy Process Questionnaire were generally good to excellent, as demonstrated by (a) exploratory factor analyses on both patient and therapist ratings, (b) CFA on later measuring times, (c) high internal consistencies and (d) significant outcome predictive effects. The parallel forms of the ITPQ deliver opportunities to compare the patient and therapist perspectives for a broader range of facets of change mechanisms than was hitherto possible. Consequently, the measure can be applied in future research to more specifically analyse different change mechanism profiles in session-to-session development and outcome prediction. Key Practitioner Message This article describes the development of an instrument that measures general mechanisms of change in psychotherapy from both the patient and therapist perspectives. Post-session item ratings from both the patient and therapist can be used as feedback to optimize therapeutic processes. We provide a detailed discussion of measures developed to evaluate therapeutic change mechanisms. Copyright © 2014 John Wiley & Sons, Ltd.

  9. Lesion to the nigrostriatal dopamine system disrupts stimulus-response habit formation.

    PubMed

    Faure, Alexis; Haberland, Ulrike; Condé, Françoise; El Massioui, Nicole

    2005-03-16

    Acquisition and performance of instrumental actions are assumed to require both action-outcome and stimulus-response (S-R) habit processes. Over the course of extended training, control over instrumental performance shifts from goal-directed action-outcome associations to S-R associations that progressively gain domination over behavior. Lesions of the lateral part of the dorsal striatum disrupt this process, and rats with lesions to the lateral striatum showed selective sensitivity to devaluation of the instrumental outcome (Yin et al., 2004), indicating that this area is necessary for habit formation. The present experiment further explored the basis of this dysfunction by examining the ability of rats subjected to bilateral 6-hydroxydopamine lesions of the nigrostriatal dopaminergic pathway to develop behavioral autonomy with overtraining. Rats were given extended training on two cued instrumental tasks associating a stimulus (a tone or a light) with an instrumental action (lever press or chain pull) and a food reward (pellets or sucrose). Both tasks were run daily in separate sessions. Overtraining was followed by a test of goal sensitivity by satiety-specific devaluation of the reward. In control animals, one action (lever press) was insensitive to reward devaluation, indicating that it became a habit, whereas the second action (chain pull) was still sensitive to goal devaluation. This result provides evidence that the development of habit learning may depend on the characteristics of the response. In dopamine-depleted rats, lever press and chain pull remained sensitive to reward devaluation, evidencing a role of striatal dopamine transmission in habit formation.

  10. Perception of competence in middle school physical education: instrument development and validation.

    PubMed

    Scrabis-Fletcher, Kristin; Silverman, Stephen

    2010-03-01

    Perception of Competence (POC) has been studied extensively in physical activity (PA) research with similar instruments adapted for physical education (PE) research. Such instruments do not account for the unique PE learning environment. Therefore, an instrument was developed and the scores validated to measure POC in middle school PE. A multiphase design was used consisting of an intensive theoretical review, elicitation study, prepilot study, pilot study, content validation study, and final validation study (N=1281). Data analysis included a multistep iterative process to identify the best model fit. A three-factor model for POC was tested and resulted in root mean square error of approximation = .09, root mean square residual = .07, goodness offit index = .90, and adjusted goodness offit index = .86 values in the acceptable range (Hu & Bentler, 1999). A two-factor model was also tested and resulted in a good fit (two-factor fit indexes values = .05, .03, .98, .97, respectively). The results of this study suggest that an instrument using a three- or two-factor model provides reliable and valid scores ofPOC measurement in middle school PE.

  11. Principles of survey development for telemedicine applications.

    PubMed

    Demiris, George

    2006-01-01

    Surveys can be used in the evaluation of telemedicine applications but they must be properly designed, consistent and accurate. The purpose of the survey and the resources available will determine the extent of testing that a survey instrument should undergo prior to its use. The validity of an instrument is the correspondence between what is being measured and what was intended to be measured. The reliability of an instrument describes the 'consistency' or 'repeatability' of the measurements made with it. Survey instruments should be designed and tested following basic principles of survey development. The actual survey administration also requires consideration, for example data collection and processing, as well as the interpretation of the findings. Surveys are of two different types. Either they are self-administered, or they are administered by interview. In the latter case, they may be administered by telephone or in a face-to-face meeting. It is important to design a survey instrument based on a detailed definition of what it intends to measure and to test it before administering it to the larger sample.

  12. Instrument Selection for Randomized Controlled Trials Why This and Not That?

    PubMed Central

    Records, Kathie; Keller, Colleen; Ainsworth, Barbara; Permana, Paska

    2011-01-01

    A fundamental linchpin for obtaining rigorous findings in quantitative research involves the selection of survey instruments. Psychometric recommendations are available for the processes for scale development and testing and guidance for selection of established scales. These processes are necessary to address the validity link between the phenomena under investigation, the empirical measures and, ultimately, the theoretical ties between these and the world views of the participants. Detailed information is most often provided about study design and protocols, but far less frequently is a detailed theoretical explanation provided for why specific instruments are chosen. Guidance to inform choices is often difficult to find when scales are needed for specific cultural, ethnic, or racial groups. This paper details the rationale underlying instrument selection for measurement of the major processes (intervention, mediator and moderator variables, outcome variables) in an ongoing study of postpartum Latinas, Madres para la Salud [Mothers for Health]. The rationale underpinning our choices includes a discussion of alternatives, when appropriate. These exemplars may provide direction for other intervention researchers who are working with specific cultural, racial, or ethnic groups or for other investigators who are seeking to select the ‘best’ instrument. Thoughtful consideration of measurement and articulation of the rationale underlying our choices facilitates the maintenance of rigor within the study design and improves our ability to assess study outcomes. PMID:21986392

  13. The Development and Application of a STEAM Program Based on Traditional Korean Culture

    ERIC Educational Resources Information Center

    Kim, Hyoungbum; Chae, Dong-Hyun

    2016-01-01

    The purpose of this research was to develop a STEAM program in the context of teaching and learning a traditional Korean instrument and implement it in a high school class to determine the program's effectiveness. The STEAM program was developed through a continuous consultation process between a development team and external experts, including an…

  14. The Children's Play Therapy Instrument (CPTI). Description, development, and reliability studies.

    PubMed

    Kernberg, P F; Chazan, S E; Normandin, L

    1998-01-01

    The Children's Play Therapy Instrument (CPTI), its development, and reliability studies are described. The CPTI is a new instrument to examine a child's play activity in individual psychotherapy. Three independent raters used the CPTI to rate eight videotaped play therapy vignettes. Results were compared with the authors' consensual scores from a preliminary study. Generally good to excellent levels of interrater reliability were obtained for the independent raters on intraclass correlation coefficients for ordinal categories of the CPTI. Likewise, kappa levels were acceptable to excellent for nominal categories of the scale. The CPTI holds promise to become a reliable measure of play activity in child psychotherapy. Further research is needed to assess discriminant validity of the CPTI for use as a diagnostic tool and as a measure of process and outcome.

  15. Design and testing of an assessment instrument to measure understanding of protein structure and enzyme inhibition in a new context.

    PubMed

    Villafañe, Sachel M; Heyen, Bruce J; Lewis, Jennifer E; Loertscher, Jennifer; Minderhout, Vicky; Murray, Tracey Arnold

    2016-01-01

    Assessment instruments designed to measure student conceptual understanding and skills proficiency related to biochemistry are important to transform undergraduate biochemistry education. The purpose of this study was to develop an assessment instrument to measure student understanding of protein structure and enzyme inhibition in a new context, that of saturable binding. A community of biochemistry educators was involved in an iterative process of designing and testing of this assessment, which consists of true/false and open-ended questions that map to low and high levels in Bloom's taxonomy. A total of 188 students' responses were collected from seven different institutions and were graded by two independent raters using a rubric. Results from this administration indicate that most students were able to answer the questions related to lower-levels in Bloom's taxonomy; however for higher-level questions, students had more difficulty. The results from this assessment can give instructors insight into the ways in which persistent incorrect or incomplete ideas related to protein structure and binding events can hinder knowledge application. Also, the use of a community of practice to develop assessment instruments of this type and the format of the instrument itself could be a useful model for development of assessment instruments in the future. © 2015 The International Union of Biochemistry and Molecular Biology.

  16. The ExoMars Science Data Archive: Status and Plans

    NASA Astrophysics Data System (ADS)

    Heather, David; Barbarisi, Isa; Brumfitt, Jon; Lim, Tanya; Metcalfe, Leo; Villacorta, Antonio

    2017-04-01

    The ExoMars program is a co-operation between ESA and Roscosmos comprising two missions: the first, launched on 14 March 2016, included the Trace Gas Orbiter and Schiaparelli lander; the second, due for launch in 2020, will be a Rover and Surface Platform (RSP). The archiving and management of the science data to be returned from ExoMars will require a significant development effort for the new Planetary Science Archive (PSA). These are the first data in the PSA to be formatted according to the new PDS4 Standards, and there are also significant differences in the way in which a scientist will want to query, retrieve, and use data from a suite of rover instruments as opposed to remote sensing instrumentation from an orbiter. NASA has a strong user community interaction for their rovers, and a similar approach to their 'Analysts Notebook' will be needed for the future PSA. In addition to the archiving interface itself, there are differences with the overall archiving process being followed for ExoMars compared to previous ESA planetary missions. The first level of data processing for the 2016 mission, from telemetry to raw, is completed by ESA at ESAC in Madrid, where the archive itself resides. Data continuously flow direct to the PSA, where after the given proprietary period, they will be released to the community via the user interfaces. For the rover mission, the data pipelines are being developed by European industry, in close collaboration with ESA PSA experts and with the instrument teams. The first level of data processing will be carried out for all instruments at ALTEC in Turin where the pipelines are developed, and from where the rover operations will also be run. This presentation will focus on the challenges involved in archiving the data from the ExoMars Program, and will outline the plans and current status of the system being developed to respond to the needs of the missions.

  17. Development and Initial Validation of the Volition in Exercise Questionnaire (VEQ)

    ERIC Educational Resources Information Center

    Elsborg, P.; Wikman, J. M.; Nielsen, G.; Tolver, A.; Elbe, A.-M.

    2017-01-01

    The present study describes the development and validation of an instrument to measure volition in the exercise context. Volition describes an individual's self-regulatory mental processes that are responsible for taking and maintaining a desirable action (e.g., exercising regularly). The scale structure was developed in an exploratory factor…

  18. Development of a quality-of-life instrument for autoimmune bullous disease: the Autoimmune Bullous Disease Quality of Life questionnaire.

    PubMed

    Sebaratnam, Deshan F; Hanna, Anna Marie; Chee, Shien-ning; Frew, John W; Venugopal, Supriya S; Daniel, Benjamin S; Martin, Linda K; Rhodes, Lesley M; Tan, Jeremy Choon Kai; Wang, Charles Qian; Welsh, Belinda; Nijsten, Tamar; Murrell, Dédée F

    2013-10-01

    Quality-of-life (QOL) evaluation is an increasingly important outcome measure in dermatology, with disease-specific QOL instruments being the most sensitive to changes in disease status. To develop a QOL instrument specific to autoimmune bullous disease (AIBD). A comprehensive item generation process was used to build a 45-item pilot Autoimmune Bullous Disease Quality of Life (ABQOL) questionnaire, distributed to 70 patients with AIBD. Experts in bullous disease refined the pilot ABQOL before factor analysis was performed to yield the final ABQOL questionnaire of 17 questions. We evaluated validity and reliability across a range of indices. Australian dermatology outpatient clinics and private dermatology practices. PATIENTS AND EXPOSURE: Patients with a histological diagnosis of AIBD. The development of an AIBD-specific QOL instrument. Face and content validity were established through the comprehensive patient interview process and expert review. In terms of convergent validity, the ABQOL was found to have a moderate correlation with scores on the Dermatology Life Quality Index (R = 0.63) and the General Health subscale of the 36-Item Short Form Health Survey (R = 0.69; P = .009) and low correlation with the Pemphigus Disease Area Index (R = 0.42) and Autoimmune Bullous Disease Skin Disorder Intensity Score (R = 0.48). In terms of discriminant validity, the ABQOL was found to be more sensitive than the Dermatology Life Quality Index (P = .02). The ABQOL was also found to be a reliable instrument evaluated by internal consistency (Cronbach α coefficient, 0.84) and test-retest reliability (mean percentage variation, 0.92). The ABQOL has been shown to be a valid and reliable instrument that may serve as an end point in clinical trials. Future work should include incorporating patient weighting on questions to further increase content validity and translation of the measure to other languages. anzctr.org.au Identifier: ACTRN12612000750886.

  19. Effect of the crushing process on Raman analyses: consequences for the Mars 2018 mission

    NASA Astrophysics Data System (ADS)

    Foucher, Frédéric; Westall, Frances; Bost, Nicolas; Rull, Fernando; Lopez-Reyes, Guillermo; Rüßmann, Philipp

    2012-07-01

    The payload of the 2018 Mars mission will comprise a Raman spectrometer as part of its instrument suite. Analyses with this instrument will be made on crushed samples. The crushing process will cause loss of important structural context and could change the physical properties of the studied materials resulting in misinterpretation of the data. We therefore investigated the influence of granulometry on the Raman spectrum of various minerals and rocks using laboratory equipment and the RLS Raman instrument being developed for the Pasteur payload of the ExoMars mission. The aim was to determine what influence the crushing process could have on the correct identification of rocks and minerals and the detection of possible traces of life. Whatever the sample type, our study shows that the crushing process leads to a strong increase in the background level and to a decrease in the signal/noise ratio. Moreover, for certain minerals, the Raman spectra can be significantly modified: the peaks are shifted and broadened and new peaks can appear. Since mineral identification using Raman spectroscopy is made by comparison with database spectra, this kind of change could lead to misinterpretation of the spectra and thus must be taken into account during the in situ investigation. However, the results obtained with the ExoMars instrument showed that, probably due to its irradiance and resolution characteristics, these effects are relatively limited and most of the time not observed with the RLS instrument. Finally, the loss of texture associated with the crushing process is shown to complicate identification of rocks with subsequent consequences for the eventual detection and interpretation of past traces of life. But, on the other hand, it is shown that the mixing of the components in the powder could facilitate the detection of minor phases.

  20. Using XML and Java for Astronomical Instrument Control

    NASA Astrophysics Data System (ADS)

    Koons, L.; Ames, T.; Evans, R.; Warsaw, C.; Sall, K.

    1999-12-01

    Traditionally, instrument command and control systems have been highly specialized, consisting mostly of custom code that is difficult to develop, maintain, and extend. Such solutions are initially very costly and are inflexible to subsequent engineering change requests. Instrument description is too tightly coupled with details of implementation. NASA/Goddard Space Flight Center and AppNet, Inc. are developing a very general and highly extensible framework that applies to virtually any kind of instrument that can be controlled by a computer (e.g., telescopes, microscopes and printers). A key aspect of the object-oriented architecture, implemented in Java, involves software that is driven by an instrument description. The Astronomical Instrument Markup Language (AIML) is a domain-specific implementation of the more generalized Instrument Markup Language (IML). The software architecture combines the platform-independent processing capabilities of Java with the vendor-independent data description syntax of Extensible Markup Language (XML), a human-readable and machine-understandable way to describe structured data. IML is used to describe command sets (including parameters, datatypes, and constraints) and their associated formats, telemetry, and communication mechanisms. The software uses this description to present graphical user interfaces to control and monitor the instrument. Recent efforts have extended to command procedures (scripting) and representation of data pipeline inputs, outputs, and connections. Near future efforts are likely to include an XML description of data visualizations, as well as the potential use of XSL (Extensible Stylesheet Language) to permit astronomers to customize the user interface on several levels: per user, instrument, subsystem, or observatory-wide. Our initial prototyping effort was targeted for HAWC (High-resolution Airborne Wideband Camera), a first-light instrument of SOFIA (the Stratospheric Observatory for Infrared Astronomy). A production-level application of this technology is for one of the three candidate detectors of SPIRE (Spectral and Photometric Imaging REceiver), a focal plane instrument proposed for the European Space Agency's Far Infrared Space Telescope. The detectors are being developed by the Infrared Astrophysics Branch of NASA/GSFC.

  1. Pilot study of the development of a theory-based instrument to evaluate the communication process during multidisciplinary team conferences in rheumatology.

    PubMed

    Verhoef, J; Toussaint, P J; Putter, H; Zwetsloot-Schonk, J H M; Vliet Vlieland, T P M

    2005-10-01

    Coordinated teams with multidisciplinary team conferences are generally seen as a solution to the management of complex health conditions. However, problems regarding the process of communication during team conferences are reported, such as the absence of a common language or viewpoint and the exchange of irrelevant or repeated information. To determine the outcome of interventions aimed at improving communication during team conferences, a reliable and valid assessment method is needed. To investigate the feasibility of a theory-based measurement instrument for assessing the process of the communication during multidisciplinary team conferences in rheumatology. An observation instrument was developed based on communication theory. The instrument distinguishes three types of communication: (I) grounding activities, (II) coordination of non-team activities, and (III) coordination of team activities. To assess the process of communication during team conferences in a rheumatology clinic with inpatient and day patient facilities, team conferences were videotaped. To determine the inter-rater reliability, in 20 conferences concerning 10 patients with rheumatoid arthritis admitted to the inpatient unit, the instrument was applied by two investigators independently. Content validity was determined by analysing and comparing the results of initial and follow-up team conferences of 25 consecutive patients with rheumatoid arthritis admitted to the day patient unit (Wilcoxon signed rank test). The inter-rater reliability was excellent with the intra-class correlation coefficients being >0.98 for both types I and III communications in 10 initial and 10 follow-up conferences (type II was not observed). An analysis of an additional 25 initial and 86 follow-up team conferences showed that time spent on grounding (type I) made up the greater part of the contents of communication (87% S.D. 14 and 60% S.D. 29 in initial and follow-up conferences, respectively), which is significantly more compared to time spent on co-ordination (p<0.001 and 0.02 for categories II and III, respectively). Moreover, significantly less time spent was spent on grounding in follow-up as compared to initial team conferences, whereas the time spent on coordination (type III) increased (both p-values<0.001). This theory-based measurement instrument for describing and evaluating the communication process during team conferences proved to be reliable and valid in this pilot study. Its usefulness to detect changes in the communication process, e.g. after implementing systems for re-structuring team conferences mediated by ICT applications, should be further examined.

  2. Generic health literacy measurement instruments for children and adolescents: a systematic review of the literature.

    PubMed

    Okan, Orkan; Lopes, Ester; Bollweg, Torsten Michael; Bröder, Janine; Messer, Melanie; Bruland, Dirk; Bond, Emma; Carvalho, Graça S; Sørensen, Kristine; Saboga-Nunes, Luis; Levin-Zamir, Diane; Sahrai, Diana; Bittlingmayer, Uwe H; Pelikan, Jürgen M; Thomas, Malcolm; Bauer, Ullrich; Pinheiro, Paulo

    2018-01-22

    Health literacy is an important health promotion concern and recently children and adolescents have been the focus of increased academic attention. To assess the health literacy of this population, researchers have been focussing on developing instruments to measure their health literacy. Compared to the wider availability of instruments for adults, only a few tools are known for younger age groups. The objective of this study is to systematically review the field of generic child and adolescent health literacy measurement instruments that are currently available. A systematic literature search was undertaken in five databases (PubMed, CINAHL, PsycNET, ERIC, and FIS) on articles published between January 1990 and July 2015, addressing children and adolescents ≤18 years old. Eligible articles were analysed, data was extracted, and synthesised according to review objectives. Fifteen generic health literacy measurement instruments for children and adolescents were identified. All, except two, are self-administered instruments. Seven are objective measures (performance-based tests), seven are subjective measures (self-reporting), and one uses a mixed-method measurement. Most instruments applied a broad and multidimensional understanding of health literacy. The instruments were developed in eight different countries, with most tools originating in the United States (n = 6). Among the instruments, 31 different components related to health literacy were identified. Accordingly, the studies exhibit a variety of implicit or explicit conceptual and operational definitions, and most instruments have been used in schools and other educational contexts. While the youngest age group studied was 7-year-old children within a parent-child study, there is only one instrument specifically designed for primary school children and none for early years. Despite the reported paucity of health literacy research involving children and adolescents, an unexpected number of health literacy measurement studies in children's populations was found. Most instruments tend to measure their own specific understanding of health literacy and not all provide sufficient conceptual information. To advance health literacy instruments, a much more standardised approach is necessary including improved reporting on the development and validation processes. Further research is required to improve health literacy instruments for children and adolescents and to provide knowledge to inform effective interventions.

  3. The Society for Implementation Research Collaboration Instrument Review Project: a methodology to promote rigorous evaluation.

    PubMed

    Lewis, Cara C; Stanick, Cameo F; Martinez, Ruben G; Weiner, Bryan J; Kim, Mimi; Barwick, Melanie; Comtois, Katherine A

    2015-01-08

    Identification of psychometrically strong instruments for the field of implementation science is a high priority underscored in a recent National Institutes of Health working meeting (October 2013). Existing instrument reviews are limited in scope, methods, and findings. The Society for Implementation Research Collaboration Instrument Review Project's objectives address these limitations by identifying and applying a unique methodology to conduct a systematic and comprehensive review of quantitative instruments assessing constructs delineated in two of the field's most widely used frameworks, adopt a systematic search process (using standard search strings), and engage an international team of experts to assess the full range of psychometric criteria (reliability, construct and criterion validity). Although this work focuses on implementation of psychosocial interventions in mental health and health-care settings, the methodology and results will likely be useful across a broad spectrum of settings. This effort has culminated in a centralized online open-access repository of instruments depicting graphical head-to-head comparisons of their psychometric properties. This article describes the methodology and preliminary outcomes. The seven stages of the review, synthesis, and evaluation methodology include (1) setting the scope for the review, (2) identifying frameworks to organize and complete the review, (3) generating a search protocol for the literature review of constructs, (4) literature review of specific instruments, (5) development of an evidence-based assessment rating criteria, (6) data extraction and rating instrument quality by a task force of implementation experts to inform knowledge synthesis, and (7) the creation of a website repository. To date, this multi-faceted and collaborative search and synthesis methodology has identified over 420 instruments related to 34 constructs (total 48 including subconstructs) that are relevant to implementation science. Despite numerous constructs having greater than 20 available instruments, which implies saturation, preliminary results suggest that few instruments stem from gold standard development procedures. We anticipate identifying few high-quality, psychometrically sound instruments once our evidence-based assessment rating criteria have been applied. The results of this methodology may enhance the rigor of implementation science evaluations by systematically facilitating access to psychometrically validated instruments and identifying where further instrument development is needed.

  4. The Development of Point Doppler Velocimeter Data Acquisition and Processing Software

    NASA Technical Reports Server (NTRS)

    Cavone, Angelo A.

    2008-01-01

    In order to develop efficient and quiet aircraft and validate Computational Fluid Dynamic predications, aerodynamic researchers require flow parameter measurements to characterize flow fields about wind tunnel models and jet flows. A one-component Point Doppler Velocimeter (pDv), a non-intrusive, laser-based instrument, was constructed using a design/develop/test/validate/deploy approach. A primary component of the instrument is software required for system control/management and data collection/reduction. This software along with evaluation algorithms, advanced pDv from a laboratory curiosity to a production level instrument. Simultaneous pDv and pitot probe velocity measurements obtained at the centerline of a flow exiting a two-inch jet, matched within 0.4%. Flow turbulence spectra obtained with pDv and a hot-wire detected the primary and secondary harmonics with equal dynamic range produced by the fan driving the flow. Novel,hardware and software methods were developed, tested and incorporated into the system to eliminate and/or minimize error sources and improve system reliability.

  5. [Development of an instrument for the surveillance of quality indicators in specialized training in Preventive Medicine and Public Health].

    PubMed

    Gil-Borrelli, Christian Carlo; Latasa, Pello; Reques, Laura; Alemán, Guadalupe

    2015-01-01

    This study describes the process of developing an instrument intended for use in assessing satisfaction with the quality of training in preventive medicine and public health for resident physicians. To develop this instrument, the National Survey of Satisfaction with Medical Residency was adapted by an expert panel consisting of 23 resident physicians in preventive medicine and public health belonging to 9 autonomous communities in Spain. The adaptation of the survey to the specialty rotations included new dimensions and items and was evaluated with a 5-point Likert scale. The most important dimensions were planning and the achievement of specific objectives, supervision, delegation of responsibilities, resources and work environment, personal assessment, encouragement, support, and whether the rotation resulted in a publication or research project, etc. The development and utilization of this tool will enable future trainees in preventive medicine and public health to make an informed choice about their training itineraries. Copyright © 2015 SESPAS. Published by Elsevier Espana. All rights reserved.

  6. Didactical determinants use of information and communication technology in process of training of future specialists.

    PubMed

    Palamar, Borys I; Vaskivska, Halyna O; Palamar, Svitlana P

    In the article the author touches upon the subject of significance of computer equipment for organization of cooperation of professor and future specialists. Such subject-subject interaction may be directed to forming of professional skills of future specialists. By using information and communication technologies in education system range of didactic tasks can be solved. Improving of process of teaching of subjects in high school, self-learning future specialists, motivating to learning and self-learning, the development of reflection in the learning process. The authors considers computer equipment as instrument for development of intellectual skills, potential and willingness of future specialists to solve communicative and communication tasks and problems on the creative basis. Based on results of researches the author comes to certain conclusions about the effectiveness of usage of computer technologies in process of teaching future specialists and their self-learning. Improper supplying of high schools with computer equipment, lack of appropriate educational programs, professors' teachers' poor knowledge and usage of computers have negative impact on organization of process of teaching disciplines in high schools. Computer equipment and ICT in general are the instruments of development of intellectual skills, potential and willingness of future specialists to solve communicative and communication tasks and problems. So, the formation of psychosocial environment of development of future specialist is multifaceted, complex and didactically important issue.

  7. Development process of an assessment tool for disruptive behavior problems in cross-cultural settings: the Disruptive Behavior International Scale – Nepal version (DBIS-N)

    PubMed Central

    Burkey, Matthew D.; Ghimire, Lajina; Adhikari, Ramesh P.; Kohrt, Brandon A.; Jordans, Mark J. D.; Haroz, Emily; Wissow, Lawrence

    2017-01-01

    Systematic processes are needed to develop valid measurement instruments for disruptive behavior disorders (DBDs) in cross-cultural settings. We employed a four-step process in Nepal to identify and select items for a culturally valid assessment instrument: 1) We extracted items from validated scales and local free-list interviews. 2) Parents, teachers, and peers (n=30) rated the perceived relevance and importance of behavior problems. 3) Highly rated items were piloted with children (n=60) in Nepal. 4) We evaluated internal consistency of the final scale. We identified 49 symptoms from 11 scales, and 39 behavior problems from free-list interviews (n=72). After dropping items for low ratings of relevance and severity and for poor item-test correlation, low frequency, and/or poor acceptability in pilot testing, 16 items remained for the Disruptive Behavior International Scale—Nepali version (DBIS-N). The final scale had good internal consistency (α=0.86). A 4-step systematic approach to scale development including local participation yielded an internally consistent scale that included culturally relevant behavior problems. PMID:28093575

  8. Development of the University of Washington Biofuels and Biobased Chemicals Process Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gustafson, Richard

    2014-02-04

    The funding from this research grant enabled us to design and build a bioconversion steam explosion reactor and ancillary equipment such as a high pressure boiler and a fermenter to support the bioconversion process research. This equipment has been in constant use since its installation in 2012. Following are research projects that it has supported: • Investigation of novel chip production method in biofuels production • Investigation of biomass refining following steam explosion • Several studies on use of different biomass feedstocks • Investigation of biomass moisture content on pretreatment efficacy. • Development of novel instruments for biorefinery process controlmore » Having this equipment was also instrumental in the University of Washington receiving a $40 million grant from the US Department of Agriculture for biofuels development as well as several other smaller grants. The research that is being done with the equipment from this grant will facilitate the establishment of a biofuels industry in the Pacific Northwest and enable the University of Washington to launch a substantial biofuels and bio-based product research program.« less

  9. Determinants of job stress in chemical process industry: A factor analysis approach.

    PubMed

    Menon, Balagopal G; Praveensal, C J; Madhu, G

    2015-01-01

    Job stress is one of the active research domains in industrial safety research. The job stress can result in accidents and health related issues in workers in chemical process industries. Hence it is important to measure the level of job stress in workers so as to mitigate the same to avoid the worker's safety related problems in the industries. The objective of this study is to determine the job stress factors in the chemical process industry in Kerala state, India. This study also aims to propose a comprehensive model and an instrument framework for measuring job stress levels in the chemical process industries in Kerala, India. The data is collected through a questionnaire survey conducted in chemical process industries in Kerala. The collected data out of 1197 surveys is subjected to principal component and confirmatory factor analysis to develop the job stress factor structure. The factor analysis revealed 8 factors that influence the job stress in process industries. It is also found that the job stress in employees is most influenced by role ambiguity and the least by work environment. The study has developed an instrument framework towards measuring job stress utilizing exploratory factor analysis and structural equation modeling.

  10. Process evaluation in a multisite, primary obesity-prevention trial in American Indian schoolchildren.

    PubMed

    Helitzer, D L; Davis, S M; Gittelsohn, J; Going, S B; Murray, D M; Snyder, P; Steckler, A B

    1999-04-01

    We describe the development, implementation, and use of the process evaluation component of a multisite, primary obesity prevention trial for American Indian schoolchildren. We describe the development and pilot testing of the instruments, provide some examples of the criteria for instrument selection, and provide examples of how process evaluation results were used to document and refine intervention components. The theoretical and applied framework of the process evaluation was based on diffusion theory, social learning theory, and the desire for triangulation of multiple modes of data collection. The primary objectives of the process evaluation were to systematically document the training process, content, and implementation of 4 components of the intervention. The process evaluation was developed and implemented collaboratively so that it met the needs of both the evaluators and those who would be implementing the intervention components. Process evaluation results revealed that observation and structured interviews provided the most informative data; however, these methods were the most expensive and time consuming and required the highest level of skill to undertake. Although the literature is full of idealism regarding the uses of process evaluation for formative and summative purposes, in reality, many persons are sensitive to having their work evaluated in such an in-depth, context-based manner as is described. For this reason, use of structured, quantitative, highly objective tools may be more effective than qualitative methods, which appear to be more dependent on the skills and biases of the researcher and the context in which they are used.

  11. Electro optical system to measure strains

    NASA Astrophysics Data System (ADS)

    Sciammarella, C. A.; Bhat, G.

    With the advent of the so called speckle interferometry, interferograms of objects can be obtained in real time by using a TV camera as the recording medium. The basic idea of this instrument is to couple the photoelectric registration by a TV camera with the subsequent electronic processing, to develop an efficient device for the measurement of deformations. This paper presents a new and improved instrument, which has a very important feature, portability, that can be operated in different modes and is capable of producing interferograms using holography, speckle, and moire methods. The basic features of the instrument are presented and some of the theoretical points at the foundation of operation of the instrument are analyzed. Examples are given of the application to moire, speckle, and holographic interferometry.

  12. The Thirty Gigahertz Instrument Receiver for the QUIJOTE Experiment: Preliminary Polarization Measurements and Systematic-Error Analysis

    PubMed Central

    Casas, Francisco J.; Ortiz, David; Villa, Enrique; Cano, Juan L.; Cagigas, Jaime; Pérez, Ana R.; Aja, Beatriz; Terán, J. Vicente; de la Fuente, Luisa; Artal, Eduardo; Hoyland, Roger; Génova-Santos, Ricardo

    2015-01-01

    This paper presents preliminary polarization measurements and systematic-error characterization of the Thirty Gigahertz Instrument receiver developed for the QUIJOTE experiment. The instrument has been designed to measure the polarization of Cosmic Microwave Background radiation from the sky, obtaining the Q, U, and I Stokes parameters of the incoming signal simultaneously. Two kinds of linearly polarized input signals have been used as excitations in the polarimeter measurement tests in the laboratory; these show consistent results in terms of the Stokes parameters obtained. A measurement-based systematic-error characterization technique has been used in order to determine the possible sources of instrumental errors and to assist in the polarimeter calibration process. PMID:26251906

  13. Application of NASA-developed technology to the automatic control of municipal sewage treatment plants

    NASA Technical Reports Server (NTRS)

    Hiser, L. L.; Herrera, W. R.

    1973-01-01

    A search was made of NASA developed technology and commercial technology for process control sensors and instrumentation which would be applicable to the operation of municipal sewage treatment plants. Several notable items were found from which process control concepts were formulated that incorporated these items into systems to automatically operate municipal sewage treatment plants. A preliminary design of the most promising concept was developed into a process control scheme for an activated sludge treatment plant. This design included process control mechanisms for maintaining constant food to sludge mass (F/M) ratio, and for such unit processes as primary sedimentation, sludge wastage, and underflow control from the final clarifier.

  14. Process control integration requirements for advanced life support systems applicable to manned space missions

    NASA Technical Reports Server (NTRS)

    Spurlock, Paul; Spurlock, Jack M.; Evanich, Peggy L.

    1991-01-01

    An overview of recent developments in process-control technology which might have applications in future advanced life support systems for long-duration space operations is presented. Consideration is given to design criteria related to control system selection and optimization, and process-control interfacing methodology. Attention is also given to current life support system process control strategies, innovative sensors, instrumentation and control, and innovations in process supervision.

  15. Core Community Specifications for Electron Microprobe Operating Systems: Software, Quality Control, and Data Management Issues

    NASA Technical Reports Server (NTRS)

    Fournelle, John; Carpenter, Paul

    2006-01-01

    Modem electron microprobe systems have become increasingly sophisticated. These systems utilize either UNIX or PC computer systems for measurement, automation, and data reduction. These systems have undergone major improvements in processing, storage, display, and communications, due to increased capabilities of hardware and software. Instrument specifications are typically utilized at the time of purchase and concentrate on hardware performance. The microanalysis community includes analysts, researchers, software developers, and manufacturers, who could benefit from exchange of ideas and the ultimate development of core community specifications (CCS) for hardware and software components of microprobe instrumentation and operating systems.

  16. Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods.

    PubMed

    Gambarini, Gianluca; Grande, Nicola Maria; Plotino, Gianluca; Somma, Francesco; Garala, Manish; De Luca, Massimo; Testarelli, Luca

    2008-08-01

    The aim of the present study was to investigate whether cyclic fatigue resistance is increased for nickel-titanium instruments manufactured by using new processes. This was evaluated by comparing instruments produced by using the twisted method (TF; SybronEndo, Orange, CA) and those using the M-wire alloy (GTX; Dentsply Tulsa-Dental Specialties, Tulsa, OK) with instruments produced by a traditional NiTi grinding process (K3, SybronEndo). Tests were performed with a specific cyclic fatigue device that evaluated cycles to failure of rotary instruments inside curved artificial canals. Results indicated that size 06-25 TF instruments showed a significant increase (p < 0.05) in the mean number of cycles to failure when compared with size 06-25 K3 files. Size 06-20 K3 instruments showed no significant increase (p > 0.05) in the mean number of cycles to failure when compared with size 06-20 GT series X instruments. The new manufacturing process produced nickel-titanium rotary files (TF) significantly more resistant to fatigue than instruments produced with the traditional NiTi grinding process. Instruments produced with M-wire (GTX) were not found to be more resistant to fatigue than instruments produced with the traditional NiTi grinding process.

  17. Nickel-Phosphorous Development for Total Solar Irradiance Measurement

    NASA Astrophysics Data System (ADS)

    Carlesso, F.; Berni, L. A.; Vieira, L. E. A.; Savonov, G. S.; Nishimori, M.; Dal Lago, A.; Miranda, E.

    2017-10-01

    The development of an absolute radiometer instrument is currently a effort at INPE for TSI measurements. In this work, we describe the development of black Ni-P coatings for TSI radiometers absorptive cavities. We present a study of the surface blackening process and the relationships between morphological structure, chemical composition and coating absorption. Ni-P deposits with different phosphorous content were obtained by electroless techniques on aluminum substrates with a thin zincate layer. Appropriate phosphorus composition and etching parameters process produce low reflectance black coatings.

  18. Software handlers for process interfaces

    NASA Technical Reports Server (NTRS)

    Bercaw, R. W.

    1976-01-01

    Process interfaces are developed in an effort to reduce the time, effort, and money required to install computer systems. Probably the chief obstacle to the achievement of these goals lies in the problem of developing software handlers having the same degree of generality and modularity as the hardware. The problem of combining the advantages of modular instrumentation with those of modern multitask operating systems has not been completely solved, but there are a number of promising developments. The essential principles involved are considered.

  19. Effects of Training in Functional Behavior Assessment

    ERIC Educational Resources Information Center

    Dukes, Charles; Rosenberg, Howard; Brady, Michael

    2008-01-01

    The purpose of this study was to investigate the effectiveness of training special education teachers in the process of functional behavioral assessment (FBA) and subsequent development of recommendations to promote behavior change. An original evaluation instrument was developed that included measures of special education teachers' knowledge of…

  20. A Proposed Methodology to Assess the Quality of Public Use Management in Protected Areas

    NASA Astrophysics Data System (ADS)

    Muñoz-Santos, Maria; Benayas, Javier

    2012-07-01

    In recent years, the goal of nature preservation has faced, almost worldwide, an increase in the number of visitors who are interested in experiencing protected areas resources, landscapes and stories. Spain is a good example of this process. The rapidly increasing numbers of visitors have prompted administrations and managers to offer and develop a broad network of facilities and programs in order to provide these visitors with information, knowledge and recreation. But, are we doing it the best way? This research focuses on developing and applying a new instrument for evaluating the quality of visitor management in parks. Different areas are analyzed with this instrument (78 semi-quantitative indicators): planning and management capacity (planning, funding, human resources), monitoring, reception, information, interpretation, environmental education, training, participation and volunteer's programs. Thus, we attempt to gain a general impression of the development of the existing management model, detecting strengths and weaknesses. Although Spain's National Parks constituted the specific context within which to develop the evaluation instrument, the design thereof is intended to provide a valid, robust and flexible method for application to any system, network or set of protected areas in other countries. This paper presents the instrument developed, some results obtained following its application to Spanish National parks, along with a discussion on the limits and validity thereof.

  1. A proposed methodology to assess the quality of public use management in protected areas.

    PubMed

    Muñoz-Santos, Maria; Benayas, Javier

    2012-07-01

    In recent years, the goal of nature preservation has faced, almost worldwide, an increase in the number of visitors who are interested in experiencing protected areas resources, landscapes and stories. Spain is a good example of this process. The rapidly increasing numbers of visitors have prompted administrations and managers to offer and develop a broad network of facilities and programs in order to provide these visitors with information, knowledge and recreation. But, are we doing it the best way? This research focuses on developing and applying a new instrument for evaluating the quality of visitor management in parks. Different areas are analyzed with this instrument (78 semi-quantitative indicators): planning and management capacity (planning, funding, human resources), monitoring, reception, information, interpretation, environmental education, training, participation and volunteer's programs. Thus, we attempt to gain a general impression of the development of the existing management model, detecting strengths and weaknesses. Although Spain's National Parks constituted the specific context within which to develop the evaluation instrument, the design thereof is intended to provide a valid, robust and flexible method for application to any system, network or set of protected areas in other countries. This paper presents the instrument developed, some results obtained following its application to Spanish National parks, along with a discussion on the limits and validity thereof.

  2. Virtual Instrument for Determining Rate Constant of Second-Order Reaction by pX Based on LabVIEW 8.0.

    PubMed

    Meng, Hu; Li, Jiang-Yuan; Tang, Yong-Huai

    2009-01-01

    The virtual instrument system based on LabVIEW 8.0 for ion analyzer which can measure and analyze ion concentrations in solution is developed and comprises homemade conditioning circuit, data acquiring board, and computer. It can calibrate slope, temperature, and positioning automatically. When applied to determine the reaction rate constant by pX, it achieved live acquiring, real-time displaying, automatical processing of testing data, generating the report of results; and other functions. This method simplifies the experimental operation greatly, avoids complicated procedures of manual processing data and personal error, and improves veracity and repeatability of the experiment results.

  3. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  4. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  5. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  6. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  7. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  8. Development process and initial validation of the Ethical Conflict in Nursing Questionnaire-Critical Care Version.

    PubMed

    Falcó-Pegueroles, Anna; Lluch-Canut, Teresa; Guàrdia-Olmos, Joan

    2013-06-01

    Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables 'frequency' and 'degree of conflict'. In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable 'exposure to conflict', as well as considering six 'types of ethical conflict'. An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach's alpha was used to evaluate the instrument's reliability. All analyses were performed using the statistical software PASW v19. Cronbach's alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.

  9. Health related quality of life in disorders of defecation: the Defecation Disorder List

    PubMed Central

    Voskuijl, W; van der Zaag-Loon..., H J; Ketel, I; Grootenhuis, M; Derkx, B; Benninga, M

    2004-01-01

    Background: Constipation and encopresis frequently cause problems with respect to emotional wellbeing, and social and family life. Instruments to measure Health Related Quality of Life (HRQoL) in these disorders are not available. Methods: A disease specific HRQoL instrument, the "Defecation Disorder List" (DDL) for children with constipation or functional non-retentive faecal soiling (FNRFS) was developed using accepted guidelines. For each phase of the process, different samples of patients were used. The final phase of development included 27 children. Reliability was assessed in two ways: internal consistency of domains with Cronbach's alpha, and test-retest reliability with intra-class correlation coefficients (ICC). To assess validity, comparable items and domains were correlated with Tacqol, a generic HRQoL instrument for children (TNO-AZL). Results: In the final phase of the development, 27 children completed the instrument. It consisted of 37 items in four domains. The response rate was 96%. Reliability was good for all domains, with Cronbach's alpha values ranging from 0.61 to 0.76. Measures of test-retest stability were good for all four domains with ICCs ranging from 0.82 to 0.92. Validity based on comparison with the Tacqol instrument was moderate. Conclusion: The DDL is promising as a measure of HRQoL in childhood defecation disorders. PMID:15557046

  10. Development of an instrument designed to measure employees' perceptions of workplace breastfeeding support.

    PubMed

    Greene, Sally W; Olson, Beth H

    2008-09-01

    Breastfeeding rates remain low in the United States, especially among working women. Unfortunately, no quantitative instrument exists to facilitate the examination of why women who return to work discontinue breastfeeding sooner than the general population. The objective of this study was to develop an instrument to measure female employees' perceptions of breastfeeding support in the workplace, which would be suitable for piloting with the target population. Examination of the literature, reviews with experts, and one-on-one interviews with women who had experience combining breastfeeding and work were used to create the instrument subscales and items. Examination of the literature was used to develop four subscales: company policies/work culture, manager support, co-worker support, and workflow. Expert review resulted in the addition of a fifth subscale, the physical environment of the breastfeeding space. One-on-one interviews were used to ensure that the item wording was appropriate for the target population. Eighteen items were added, and 15 were reworded based on comments from the expert review and from the interviews. The resulting survey contained 54 items that required either categorical yes/no or Likert scale responses. Results from this process indicate the survey subscales and items adequately reflect women's perceptions of breastfeeding support in the workplace and the instrument is appropriate for piloting with new mother employees.

  11. The Instrumentation of a Microfluidic Analyzer Enabling the Characterization of the Specific Membrane Capacitance, Cytoplasm Conductivity, and Instantaneous Young's Modulus of Single Cells.

    PubMed

    Wang, Ke; Zhao, Yang; Chen, Deyong; Huang, Chengjun; Fan, Beiyuan; Long, Rong; Hsieh, Chia-Hsun; Wang, Junbo; Wu, Min-Hsien; Chen, Jian

    2017-06-19

    This paper presents the instrumentation of a microfluidic analyzer enabling the characterization of single-cell biophysical properties, which includes seven key components: a microfluidic module, a pressure module, an imaging module, an impedance module, two LabVIEW platforms for instrument operation and raw data processing, respectively, and a Python code for data translation. Under the control of the LabVIEW platform for instrument operation, the pressure module flushes single cells into the microfluidic module with raw biophysical parameters sampled by the imaging and impedance modules and processed by the LabVIEW platform for raw data processing, which were further translated into intrinsic cellular biophysical parameters using the code developed in Python. Based on this system, specific membrane capacitance, cytoplasm conductivity, and instantaneous Young's modulus of three cell types were quantified as 2.76 ± 0.57 μF/cm², 1.00 ± 0.14 S/m, and 3.79 ± 1.11 kPa for A549 cells ( n cell = 202); 1.88 ± 0.31 μF/cm², 1.05 ± 0.16 S/m, and 3.74 ± 0.75 kPa for 95D cells ( n cell = 257); 2.11 ± 0.38 μF/cm², 0.87 ± 0.11 S/m, and 5.39 ± 0.89 kPa for H460 cells ( n cell = 246). As a semi-automatic instrument with a throughput of roughly 1 cell per second, this prototype instrument can be potentially used for the characterization of cellular biophysical properties.

  12. The Instrumentation of a Microfluidic Analyzer Enabling the Characterization of the Specific Membrane Capacitance, Cytoplasm Conductivity, and Instantaneous Young’s Modulus of Single Cells

    PubMed Central

    Wang, Ke; Zhao, Yang; Chen, Deyong; Huang, Chengjun; Fan, Beiyuan; Long, Rong; Hsieh, Chia-Hsun; Wang, Junbo; Wu, Min-Hsien; Chen, Jian

    2017-01-01

    This paper presents the instrumentation of a microfluidic analyzer enabling the characterization of single-cell biophysical properties, which includes seven key components: a microfluidic module, a pressure module, an imaging module, an impedance module, two LabVIEW platforms for instrument operation and raw data processing, respectively, and a Python code for data translation. Under the control of the LabVIEW platform for instrument operation, the pressure module flushes single cells into the microfluidic module with raw biophysical parameters sampled by the imaging and impedance modules and processed by the LabVIEW platform for raw data processing, which were further translated into intrinsic cellular biophysical parameters using the code developed in Python. Based on this system, specific membrane capacitance, cytoplasm conductivity, and instantaneous Young’s modulus of three cell types were quantified as 2.76 ± 0.57 μF/cm2, 1.00 ± 0.14 S/m, and 3.79 ± 1.11 kPa for A549 cells (ncell = 202); 1.88 ± 0.31 μF/cm2, 1.05 ± 0.16 S/m, and 3.74 ± 0.75 kPa for 95D cells (ncell = 257); 2.11 ± 0.38 μF/cm2, 0.87 ± 0.11 S/m, and 5.39 ± 0.89 kPa for H460 cells (ncell = 246). As a semi-automatic instrument with a throughput of roughly 1 cell per second, this prototype instrument can be potentially used for the characterization of cellular biophysical properties. PMID:28629175

  13. A Shipping Container-Based Sterile Processing Unit for Low Resources Settings

    PubMed Central

    2016-01-01

    Deficiencies in the sterile processing of medical instruments contribute to poor outcomes for patients, such as surgical site infections, longer hospital stays, and deaths. In low resources settings, such as some rural and semi-rural areas and secondary and tertiary cities of developing countries, deficiencies in sterile processing are accentuated due to the lack of access to sterilization equipment, improperly maintained and malfunctioning equipment, lack of power to operate equipment, poor protocols, and inadequate quality control over inventory. Inspired by our sterile processing fieldwork at a district hospital in Sierra Leone in 2013, we built an autonomous, shipping-container-based sterile processing unit to address these deficiencies. The sterile processing unit, dubbed “the sterile box,” is a full suite capable of handling instruments from the moment they leave the operating room to the point they are sterile and ready to be reused for the next surgery. The sterile processing unit is self-sufficient in power and water and features an intake for contaminated instruments, decontamination, sterilization via non-electric steam sterilizers, and secure inventory storage. To validate efficacy, we ran tests of decontamination and sterilization performance. Results of 61 trials validate convincingly that our sterile processing unit achieves satisfactory outcomes for decontamination and sterilization and as such holds promise to support healthcare facilities in low resources settings. PMID:27007568

  14. Significant achievements in the Planetary Geology Program. [geologic processes, comparative planetology, and solar system evolution

    NASA Technical Reports Server (NTRS)

    Head, J. W. (Editor)

    1978-01-01

    Developments reported at a meeting of principal investigators for NASA's planetology geology program are summarized. Topics covered include: constraints on solar system formation; asteriods, comets, and satellites; constraints on planetary interiors; volatiles and regoliths; instrument development techniques; planetary cartography; geological and geochemical constraints on planetary evolution; fluvial processes and channel formation; volcanic processes; Eolian processes; radar studies of planetary surfaces; cratering as a process, landform, and dating method; and the Tharsis region of Mars. Activities at a planetary geology field conference on Eolian processes are reported and techniques recommended for the presentation and analysis of crater size-frequency data are included.

  15. The U.S./IAEA Workshop on Software Sustainability for Safeguards Instrumentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pepper S. E.; .; Worrall, L.

    2014-08-08

    The U.S. National Nuclear Security Administration’s Next Generation Safeguards Initiative, the U.S. Department of State, and the International Atomic Energy Agency (IAEA) organized a a workshop on the subject of ”Software Sustainability for Safeguards Instrumentation.” The workshop was held at the Vienna International Centre in Vienna, Austria, May 6-8, 2014. The workshop participants included software and hardware experts from national laboratories, industry, government, and IAEA member states who were specially selected by the workshop organizers based on their experience with software that is developed for the control and operation of safeguards instrumentation. The workshop included presentations, to orient the participantsmore » to the IAEA Department of Safeguards software activities related to instrumentation data collection and processing, and case studies that were designed to inspire discussion of software development, use, maintenance, and upgrades in breakout sessions and to result in recommendations for effective software practices and management. This report summarizes the results of the workshop.« less

  16. Challenges of the science data processing, analysis and archiving approach in BepiColombo

    NASA Astrophysics Data System (ADS)

    Martinez, Santa

    BepiColombo is a joint mission of the European Space Agency (ESA) and the Japan Aerospace Exploration Agency (JAXA) to the planet Mercury. It comprises two separate orbiters: the Mercury Planetary Orbiter (MPO) and the Mercury Magnetospheric Orbiter (MMO). After approximately 7.5 years of cruise, BepiColombo will arrive at Mercury in 2024 and will gather data during a 1-year nominal mission, with a possible 1-year extension. The approach selected for BepiColombo for the processing, analysis and archiving of the science data represents a significant change with respect to previous ESA planetary missions. Traditionally Instrument Teams are responsible for processing, analysing and preparing their science data for the long-term archive, however in BepiColombo, the Science Ground Segment (SGS), located in Madrid, Spain, will play a key role in these activities. Fundamental aspects of this approach include: the involvement of the SGS in the definition, development and operation of the instrument processing pipelines; the production of ready-to-archive science products compatible with NASA’s Planetary Data System (PDS) standards in all the processing steps; the joint development of a quick-look analysis system to monitor deviations between planned and executed observations to feed back the results into the different planning cycles when possible; and a mission archive providing access to the scientific products and to the operational data throughout the different phases of the mission (from the early development phase to the legacy phase). In order to achieve these goals, the SGS will need to overcome a number of challenges. The proposed approach requires a flexible infrastructure able to cope with a distributed data processing system, residing in different locations but designed as a single entity. For this, all aspects related to the integration of software developed by different Instrument Teams and the alignment of their development schedules will need to be considered. In addition, the SGS is taking full responsibility for the production of the first level of science data (un-calibrated), with the associated operational implications. An additional difficulty impacting the processing strategies relates to the various spacecraft data downlink mechanisms available for the MPO and their associated data latency. With regards to archiving, the main challenges include: the use of a new version of the PDS standards (so-called PDS4), being implemented for the first time in an ESA planetary mission; the use of external standards (CDF, FITS); and the implementation of interoperability protocols that aim to make all data (from both MPO and MMO) globally accessible through a distributed archive to the end-users. For the definition of the quick-look analysis system, it is very important to understand and harmonise the different views and expectations of the science team. Due to the long duration of the Cruise phase, and the fact that there are many years between the design of the system and the nominal mission, it might be difficult for some Instrument Teams to accurately define their needs so many years before operations. In particular, new scientific discoveries over the coming years by the MESSENGER spacecraft, currently orbiting Mercury, may influence how the Instrument Teams on BepiColombo define their operations and their reduction and analysis techniques. In addition, due to the long duration of the mission, it is not always possible or practical to document all accumulated knowledge on paper so if personnel leave some of their knowledge is lost as well. This is key, particularly for the Instrument Teams. By taking a pro-active role in the collection of requirements and expectations of the science team together with the definition of clear guidelines early in the mission and by developing close collaboration with the Instrument Teams, the SGS will be able to identify how to best exploit the expertise on both sides and to guarantee that the necessary support is provided when needed. This contribution will detail the main challenges and advantages associated with the data processing, analysis and archiving approach in BepiColombo, and will summarise the various efforts ongoing to guarantee that the scientific requirements of the mission and the expectations of the science team are fulfilled. Future ESA planetary missions (e.g. ExoMars, JUICE) will follow a similar approach, adapting the efforts to the profile of the mission.

  17. Instrumentation for mechanistic design implementation.

    DOT National Transportation Integrated Search

    2010-02-01

    The Oregon Department of Transportation (ODOT) Pavement Services Unit is in the process of implementing a new pavement design : procedure being developed under the sponsorship of the American Association of State Highway and Transportation Officials....

  18. Examining perceptions of academic stress and its sources among university students: The Perception of Academic Stress Scale

    PubMed Central

    Bedewy, Dalia

    2015-01-01

    The development of a scale to measure perceived sources of academic stress among university students. Based on empirical evidence and recent literature review, we developed an 18-item scale to measure perceptions of academic stress and its sources. Experts (n = 12) participated in the content validation process of the instrument before it was administered to (n = 100) students. The developed instrument has internal consistency reliability of 0.7 (Cronbach’s alpha), there was evidence for content validity, and factor analysis resulted in four correlated and theoretically meaningful factors. We developed and tested a scale to measure academic stress and its sources. This scale takes 5 minutes to complete. PMID:28070363

  19. Expandable and reconfigurable instrument node arrays

    NASA Technical Reports Server (NTRS)

    Hilliard, Lawrence M. (Inventor); Deshpande, Manohar (Inventor)

    2012-01-01

    An expandable and reconfigurable instrument node includes a feature detection means and a data processing portion in communication with the feature detection means, the data processing portion configured and disposed to process feature information. The instrument node further includes a phase locked loop (PLL) oscillator in communication with the data processing portion, the PLL oscillator configured and disposed to provide PLL information to the processing portion. The instrument node further includes a single tone transceiver and a pulse transceiver in communication with the PLL oscillator, the single tone transceiver configured and disposed to transmit or receive a single tone for phase correction of the PLL oscillator and the pulse transceiver configured and disposed to transmit and receive signals for phase correction of the PLL oscillator. The instrument node further includes a global positioning (GPA) receiver in communication with the processing portion, the GPS receiver configured and disposed to establish a global position of the instrument node.

  20. Case study on the orientation of phaco hand pieces during steam sterilization processes.

    PubMed

    van Doornmalen Gomez Hoyos, J P C M; van Wezel, R A C; van Doornmalen, H W J M

    2015-05-01

    Steam sterilization is an essential part of infection prevention. The literature shows that sterilization of medical instruments containing channels is not trivial. Phaco hand pieces have a simple configuration: a device contains a channel with a constant radius. No literature was found indicating whether the sterilization conditions on the inner surface of a phaco hand piece are influenced by the orientation of the hand piece. To determine whether the orientation of a phaco hand piece influences the results of a sterilization process of this device. A qualitative case study, including experiments, is performed with a protocolled combination of steam sterilizer, process, phaco hand piece, orientation of the phaco hand piece, and wrapping. In this specific case, the orientation of the hand piece influenced the result of the steam sterilization process; in vertically (upright) oriented phaco hand pieces with free water drainage, sterilization conditions are reproducibly established. In the same process, in horizontally oriented or vertically oriented hand pieces without free drainage, these conditions are not established in a reproducible way. In the investigated combination of sterilizer, process, load, loading pattern and wrapping, phaco hand pieces have to be oriented vertically (upright) with free water drainage to obtain steam sterilization conditions on the inner surface. It is likely that instruments with comparable configuration and dimensions will yield comparable results. It is therefore recommended that this issue is considered during the development of medical instruments and during performance qualifications of such instruments. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

Top